Powered by Deep Web Technologies
Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Covered Product Category: Light Fixtures (Luminaires) | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fixtures (Luminaires) Covered Product Category: Light Fixtures (Luminaires) The Federal Energy Management Program (FEMP) provides acquisition guidance and Federal efficiency...

2

Cree LED Lighting Solutions Formerly LED Lighting Fixtures LLF...  

Open Energy Info (EERE)

LED Lighting Solutions Formerly LED Lighting Fixtures LLF Jump to: navigation, search Name: Cree LED Lighting Solutions (Formerly LED Lighting Fixtures (LLF)) Place: Morrisville,...

3

Recessed light fixtures: Infiltration energy loss  

SciTech Connect

This article reports that a recent study revealed that fluorescent bulbs can reduce convective energy losses by 15--65% as compared to incandescent bulbs. Recessed light fixtures are commonly installed in offices and homes. However, a problem arises in homes when the fixtures are set in the ceiling such that the top of the light fixture is exposed to the unconditioned air in the attic. Because some air flow is necessary around the light to avoid overheating, the manufacturers do not make all the fixtures leak tight, only those that are rated for lower wattage bulbs. The need for cooling the fixture may conflict with some building efficiency codes.

Bennett, S.M.; Perez-Blanco, H. (Pennsylvania State Univ., University Park, PA (United States))

1994-06-01T23:59:59.000Z

4

Covered Product Category: Light Fixtures (Luminaires)  

Energy.gov (U.S. Department of Energy (DOE))

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including luminaires, or light fixtures. The luminaires product category is very broad and covers a wide variety of lighting products. Both ENERGY STAR® and FEMP provide programmatic guidance for various types of luminaires. See table 2 for more information about which types of light fixtures are covered by which program (FEMP or ENERGY STAR). Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

5

Covered Product Category: Luminaires (Light Fixtures) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Luminaires (Light Fixtures) Luminaires (Light Fixtures) Covered Product Category: Luminaires (Light Fixtures) October 7, 2013 - 10:49am Addthis Did You Know? The ENERGY STAR luminaires product category covers a wide range of lighting products, both residential and commercial. FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including luminaires, or light fixtures. The luminaires product category is very broad and covers a wide variety of lighting products. Both ENERGY STAR® and FEMP provide programmatic guidance for various types of luminaires. See table 2 for more information about which types of light fixtures are covered by which program (FEMP or ENERGY STAR). Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and

6

New Lighting Fixtures: Combining Creativity and Style with Energy Efficiency  

SciTech Connect

This article for a building trade magazine describes a national design competition for energy efficient lighting sponsored by the U.S. Department of Energy, the American Lighting Association, and the Consortium for Energy Efficiency, with winners announced at ALA's Annual Conference May 14, 2004, in Tucson. The Lighting for Tomorrow competition was the first national lighting fixture design competition focusing on energy-efficient residential lighting. The competition invited fixture manufacturers and designers to come up with beautiful, functional lighting fixtures that also happen to be energy efficient. Fixtures were required to use a ''dedicated'' energy-efficient light source, such as a pin-based fluorescent lamp that cannot be replaced with a screw-in incandescent bulb. Fixtures also had to meet a minimum energy efficiency level that eliminated use of incandescent and halogen lamps, leaving the door open only to fluorescent sources and LEDs. More than 150 paper designs were submitted in the first phase of the competition, in 2003. Of those, 24 finalists were invited to submit working prototypes in 2004, and the winners were announced in May. The Grand Prize of $10,000 went to American Fluorescent of Waukegan, Illinois, for its ''Salem'' chandelier. Some winning fixtures are already available through Lowe's Home Improvement Centers.

Gordon, Kelly L.; Foster, Rebecca; McGowan, Terry

2004-10-01T23:59:59.000Z

7

Remediation plan for fluorescent light fixtures containing polychlorinated biphenyls (PCBs)  

SciTech Connect

This report describes the remedial action to achieve compliance with 29 CFR 1910 Occupational Safety and Health Administration (OSHA) requirements of fluorescent light fixtures containing PCBs at K-25 site. This remedial action is called the Remediation Plan for Fluorescent Light Fixtures Containing PCBs at the K-25 Site (The Plan). The Plan specifically discusses (1) conditions of non-compliance, (2) alternative solutions, (3) recommended solution, (4) remediation plan costs, (5) corrective action, (6) disposal of PCB waste, (7) training, and (8) plan conclusions. The results from inspections by Energy Systems personnel in 2 buildings at K-25 site and statistical extension of this data to 91 selected buildings at the K-25 site indicates that there are approximately 28,000 fluorescent light fixtures containing 47,036 ballasts. Approximately 38,531 contain PCBs and 2,799 of the 38,531 ballasts are leaking PCBs. Review of reportable occurrences at K-25 for the 12 month period of September 1990 through August 1991 shows that Energy Systems personnel reported 69 ballasts leaking PCBs. Each leaking ballast is in non-compliance with 29 CFR 1910 - Table Z-1-A. The age of the K-25 facilities indicate a continued and potential increase in ballasts leaking PCBs. This report considers 4 alternative solutions for dealing with the ballasts leaking PCBs. The advantages and disadvantages of each alternative solution are discussed and ranked using cost of remediation, reduction of health risks, and compliance with OSHA as criteria.

NONE

1992-04-30T23:59:59.000Z

8

Department of Mechanical Engineering Spring 2013 Lumax Lighting 2: LED Industrial High Bay Light Fixture  

E-Print Network (OSTI)

PENNSTATE Department of Mechanical Engineering Spring 2013 Lumax Lighting 2: LED Industrial High was to design a light fixture for an industrial setting using high power LED lights. The challenge with these LEDs is that they get so hot in a very little time period that the LED will fail and not work anymore

Demirel, Melik C.

9

Energy Star Lighting Fixtures: How Does THAT Work? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Star Lighting Fixtures: How Does THAT Work? Energy Star Lighting Fixtures: How Does THAT Work? Energy Star Lighting Fixtures: How Does THAT Work? May 3, 2010 - 11:49am Addthis Amy Foster Parish My husband and I spent a lazy Saturday in a lighting showroom a few weekends ago. We've been working on a project to replace all the lighting fixtures in our home for a couple of years now, so we seem to spend a lot of time in lighting showrooms. But that particular Saturday was a bit special. We were finally picking out our last fixture-the overhead light in our bedroom. Sadly, this was the second time we'd had to pick out this fixture; we had bought and attempted to install a lovely chandelier in the bedroom the previous weekend only to belatedly realize that chandeliers and eight-foot ceilings don't mix. So after returns and refunds, we were at it

10

Replacement of Lighting Fixtures with LED Energy Efficient Lights at the Parking Facility, Milwaukee, Wisconsin  

SciTech Connect

The Forest County Potawatomi Community (FCPC or Tribe) owns a six-story parking facility adjacent to its Potawatomi Bingo Casino (the Casino) in Milwaukee, Wisconsin, as well as a valet parking facility under the Casino (collectively, the Parking Facility). The Parking Facility contained 205-watt metal halide-type lights that, for security reasons, operated 24 hours per day, 7 days per week. Starting on August 30, 2010, the Tribe replaced these fixtures with 1,760 state-of-the-art, energy efficient 55-Watt LED lights. This project resulted in an immediate average reduction in monthly peak demand of 238 kW over the fourth quarter of 2010. The average reduction in monthly peak demand from October 1 through December 31, 2010 translates into a forecast annual electrical energy reduction of approximately 1,995,000 kWh or 47.3% of the pre-project demand. This project was technically effective, economically feasible, and beneficial to the public not only in terms of long term energy efficiency and associated emissions reductions, but also in the short-term jobs provided for the S.E. Wisconsin region. The project was implemented, from approval by U.S. Department of Energy (DOE) to completion, in less than 6 months. The project utilized off-the-shelf proven technologies that were fabricated locally and installed by local trade contractors.

David Brien

2012-06-21T23:59:59.000Z

11

LED Light Fixture Project FC1 Director's Conference Room: Life Cycle Cost and Break-even Analysis  

E-Print Network (OSTI)

LED Light Fixture Project ­ FC1 Director's Conference Room: Life Cycle Cost and Break-even Analysis sources. One of the emerging lighting technologies that facilities organizations are looking at are LEDs. A light-emitting diode (LED) is a solid-state lighting source that switches on instantly, is readily

Johnston, Daniel

12

Side-by-Side Testing of Commercial Office Lighting Systems: Two-lamp Fluorescent Fixtures  

E-Print Network (OSTI)

. Guide to Performance Evaluation of Efficient Lighting Products, Lighting Research Center, Rensselaer Polytechnic Institute, Troy, NY. IES, 1987. IES Lighting Handbook: 1987 Ap~lications Volume, Illuminating Engineering Society of North America, New... Transactions on Industrv A~plications, No. 5, pp. 1189-1 197. Verderber, R.R. and Rubinstein, F.M. and Ward, G., 1989. Photoelectric Control of Daylight Following Lighting Systems, CU- 6243, Electric Power Research Institute, Palo Alto, CA. Rubinstein, F...

Parker, D. S.; Schrum, L.; Sonne, J. K.; Stedman, T. C.

1996-01-01T23:59:59.000Z

13

The Energy-Efficient Fixtures Laboratory  

NLE Websites -- All DOE Office Websites (Extended Search)

0 0 The Energy-Efficient Fixtures Laboratory Replacing the incandescent bulb with a more efficient light source is only the first step in developing an energy-efficient lighting system. Improved fixtures can raise the system's efficiency even further. At LBL's Energy-Efficient Fixtures Laboratory, researchers in the Lighting Systems Group study the optical and thermal efficiency of luminaires, and work closely with fixture manufacturers to develop more efficient products. "Fifty to seventy percent efficiencies are now typical of fixtures," says senior research associate Chin Zhang, "and we're trying to improve them to eighty to ninety percent." Oliver Morse adjusts a centralized light guide system consisting of a 250-watt metal halide lamp, a high-efficiency beam splitter and four hollow

14

Thermally efficient compact fluorescent fixture systems  

SciTech Connect

Compact fluorescent lamps that can be inserted into conventional light fixtures are rapidly gaining acceptance as both a viable retrofit and new design approach to reducing lighting loads. Ideally, the compact fluorescent lamp should have the same light output as the incandescent lamp it replaces, but overheating inside typically small enclosed fixtures can reduce lumen output and hence lighting fixture efficiency by 15 to 20 percent. Fortunately, simple fixture modifications can erase this efficiency penalty, so that the full efficiency benefit of replacing incandescent lamps with fluorescent lamps can be realized. The paper describes such modifications and presents experimental data documenting the potential efficiency enhancement associated with thermal control systems. 4 refs., 7 figs.

Siminovitch, M.J.; Rubinstein, F.M.; Packer, M.

1991-04-01T23:59:59.000Z

15

Multiple direction vibration fixture  

DOE Patents (OSTI)

An apparatus for simulating a rocket launch environment on a test item undergoing centrifuge testing by subjecting the item simultaneously or separately to vibration along an axis of centripetal force and along an axis perpendicular to the centripetal force axis. The apparatus includes a shaker motor supported by centrifuge arms and a right angle fixture pivotally connected to one of the shaker motor mounts. When the shaker motor vibrates along the centripetal force axis, the vibrations are imparted to a first side of the right angle fixture. The vibrations are transmitted 90 degrees around the pivot and are directed to a second side of the right angle fixture which imparts vibrations perpendicular to the centripetal force axis. The test item is in contact with a third side of the right angle fixture and receives both centripetal-force-axis vibrations and perpendicular axis vibrations simultaneously. A test item can be attached to the third side near the flexible coupling or near the air bag to obtain vibrations along the centripetal force axis or transverse to the centripetal force axis.

Cericola, Fred (Albuquerque, NM); Doggett, James W. (Albuquerque, NM); Ernest, Terry L. (Albuquerque, NM); Priddy, Tommy G. (Rockville, MD)

1991-01-01T23:59:59.000Z

16

Controlled shear/tension fixture  

DOE Patents (OSTI)

A test fixture for simultaneously testing two material test samples is provided. The fixture provides substantially equal shear and tensile stresses in each test specimens. By gradually applying a load force to the fixture only one of the two specimens fractures. Upon fracture of the one specimen, the fixture and the load train lose contact and the second specimen is preserved in a state of upset just prior to fracture. Particular advantages of the fixture are (1) to control the tensile to shear load on the specimen for understanding the effect of these stresses on the deformation behavior of advanced materials, (2) to control the location of fracture for accessing localized material properties including the variation of the mechanical properties and residual stresses across the thickness of advanced materials, (3) to yield a fractured specimen for strength measurement and an unfractured specimen for examining the microstructure just prior to fracture.

Hsueh, Chun-Hway (Knoxville, TN); Liu, Chain-tsuan (Knoxville, TN); George, Easo P. (Knoxville, TN)

2012-07-24T23:59:59.000Z

17

Evolution of Light-Induced Vapor Generation at a Liquid-Immersed Metallic Nanoparticle  

E-Print Network (OSTI)

Evolution of Light-Induced Vapor Generation at a Liquid-Immersed Metallic Nanoparticle Zheyu Fang nanoparticle in a liquid medium is illuminated with resonant light of sufficient intensity, a nanometer scale- known process of liquid boiling, occurring at a single nanoparticle nucleation site, resulting from

Polman, Albert

18

Tillamook County PUD - Dairy Lighting Retrofit Rebate Program | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tillamook County PUD - Dairy Lighting Retrofit Rebate Program Tillamook County PUD - Dairy Lighting Retrofit Rebate Program Tillamook County PUD - Dairy Lighting Retrofit Rebate Program < Back Eligibility Agricultural Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info State Oregon Program Type Utility Rebate Program Provider Tillamook County PUD Tillamook PUD offers the Dairy Lighting Retrofit Program for its agricultural members to save energy on lighting in eligible barns/facilities. Tillamook PUD completes a lighting audit of the facility to calculate the energy savings and rebate amount. Incentives are provided for the replacement of existing mercury vapor, incandescent, and T12 fluorescent fixtures with new ORION AG9000 3-lamp T8 fluorescent fixtures. This rebate is available for retrofits only, new construction is not

19

Channelization architecture for wide-band slow light in atomic vapors  

E-Print Network (OSTI)

We propose a ``channelization'' architecture to achieve wide-band electromagnetically induced transparency (EIT) and ultra-slow light propagation in atomic Rb-87 vapors. EIT and slow light are achieved by shining a strong, resonant ``pump'' laser on the atomic medium, which allows slow and unattenuated propagation of a weaker ``signal'' beam, but only when a two-photon resonance condition is satisfied. Our wideband architecture is accomplished by dispersing a wideband signal spatially, transverse to the propagation direction, prior to entering the atomic cell. When particular Zeeman sub-levels are used in the EIT system, then one can introduce a magnetic field with a linear gradient such that the two-photon resonance condition is satisfied for each individual frequency component. Because slow light is a group velocity effect, utilizing differential phase shifts across the spectrum of a light pulse, one must then introduce a slight mismatch from perfect resonance to induce a delay. We present a model which accounts for diffusion of the atoms in the varying magnetic field as well as interaction with levels outside the ideal three-level system on which EIT is based. We find the maximum delay-bandwidth product decreases with bandwidth, and that delay-bandwidth product ~1 should be achievable with bandwidth ~50 MHz (~5 ns delay). This is a large improvement over the ~1 MHz bandwidths in conventional slow light systems and could be of use in signal processing applications.

Zachary Dutton; Mark Bashkansky; Michael Steiner; John Reintjes

2005-10-20T23:59:59.000Z

20

Light narrowing of magnetic resonance lines in dense, optically pumped alkali-metal vapor  

Science Journals Connector (OSTI)

A new and unusual phenomenon which we call light narrowing is reported and discussed in this paper. We discovered this effect in dense, spin-polarized cesium vapor optically pumped with a cw blue dye laser beam tuned to the second resonance D1 line (4593 Å). We observe a significant narrowing of the radio-frequency power-broadened magnetic resonance lines (linewidths narrow by as much as a factor of 2.5) when the intensity of the circularly polarized incident dye laser beam is increased by either focusing the beam or by the removal of attenuating filters from the focused beam. The magnetic resonance linewidths in spin-polarized cesium vapor were measured over a wide range of cesium number densities (5×1012 cm-3 ?[Cs]?1×1016 cm-3). This corresponds to cesium spinexchange rates of 4.5×103 to 9×106 sec-1. For low cesium number densities (5×1012 1×1015 cm-3) this light-narrowing effect almost completely disappears. In the limit of low-radio-frequency power the magnetic resonance linewidths for focused and unfocused dye laser beam are nearly the same. Experimental observations on this new effect are presented in detail. In the latter part of this paper a self-contained theoretical treatment of the light-narrowing effect is developed. Using Bloch equations in the presence of optical pumping, spin relaxation (diffusion, electron randomization), rapid spin exchange, and radio-frequency magnetic field, expressions for magnetic resonance line shapes are derived. In general, we find good agreement between our experimental results and the theory.

N. D. Bhaskar; J. Camparo; W. Happer; A. Sharma

1981-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Plumbing fixture patterns through audio sampling  

E-Print Network (OSTI)

weeks. The experiment involved mounting microphones on the water supply risers of different plumbing fixture groups on the first, second, and third floors of the building. The microphones fed into a sound activated relay circuit acting as a surrogate...

Shea, Kevin Bruce

2012-06-07T23:59:59.000Z

22

Fixture for forming evaporative pattern (EPC) process patterns  

DOE Patents (OSTI)

A method of casting metal using evaporative pattern casting process patterns in combination with a fixture for creating and maintaining a desired configuration in flexible patterns. A pattern is constructed and gently bent to the curvature of a suitable fixture. String or thin wire, which burns off during casting, is used to tie the pattern to the fixture. The fixture with pattern is dipped in a commercially available refractory wash to prevent metal adherence and sticking to the fixture. When the refractory wash is dry, the fixture and pattern are placed in a flask, and sand is added and compacted by vibration. The pattern remains in position, restrained by the fixture. Metal that is poured directly into the pattern replaces the pattern exactly but does not contact or weld to the fixture due to the protective refractory layer. When solid, the casting is easily separated from the fixture. The fixture can be cleaned for reuse in conventional casting cleaning equipment.

Turner, Paul C. (Albany, OR); Jordan, Ronald R. (Albany, OR); Hansen, Jeffrey S. (Corvallis, OR)

1993-01-01T23:59:59.000Z

23

Light storage via coherent population oscillation in a thermal cesium vapor  

E-Print Network (OSTI)

We report on the storage of light via the phenomenon of Coherent Population Oscillation (CPO) in an atomic cesium vapor at room temperature. In the experiment the optical information of a probe field is stored in the CPO of two ground states of a Lambda three-level system formed by the Zeeman sublevels of the hyperfine transition F = 3 - F' = 2 of cesium D2 line. We show directly that this CPO based memory is very insensitive to stray magnetic field inhomogeneities and presents a lifetime which is mainly limited only by atomic motion. A theoretical simulation of the measured spectra was also developed and is in very good agreement with the experiment.

A. J. F. de Almeida; J. Sales; M. -A. Maynard; T. Laupretre; F. Bretenaker; D. Felinto; F. Goldfarb; J. W. R. Tabosa

2014-09-19T23:59:59.000Z

24

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and  

E-Print Network (OSTI)

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and HID (high-intensity discharge) lamps and all other mercury containing labeled for shipment to a recycling plant for mercury, glass and aluminum recovery. The beneficial re

Baker, Chris I.

25

Thermal resilient multiple jaw braze fixture  

DOE Patents (OSTI)

A braze fixture has side walls forming a cavity with an opening to receive a stack of parts to be brazed. Sidewalls of the housing have a plurality of bearing receiving openings into which bearing rods or jaws are inserted to align the stacked elements of the workpiece. The housing can also have view ports to allow a visual check of the alignment. Straps or wires around the fixture are selected to have thermal characteristics similar to the thermal characteristics of the workpiece undergoing brazing. The straps or wires make physical contact with the bearing rods thereby causing bearing rods to maintain the workpiece in proper alignment throughout the entire brazing cycle.

Ney, Robert (1716 Cypress Ave., Belleair, FL 34616); Perrone, Alex J. (3005 Fontanar St., Lutz, FL 33549)

1995-07-11T23:59:59.000Z

26

New Research Tool for Energy-Efficient Residential Fixtures  

NLE Websites -- All DOE Office Websites (Extended Search)

4 4 New Research Tool for Energy-Efficient Residential Fixtures Lighting Group researcher Erik Page stands next to the new goniophotometer, shown in a multiple-exposure photo that represents a complete sensor sweep around a table lamp. The lamp is seen reflected in a mirror mounted on a swing arm, aimed at a photocell used for data acquisition. The residential lighting sector represents a significant opportunity for energy conservation because it currently uses inefficient incandescent sources almost exclusively. Compact fluorescent lamps (CFLs) have the potential to transform this market by using one-fourth as much power as an incandescent to provide the same amount of light. While technical advances such as triphosphors and electronic ballasts have addressed issues of color

27

Fixture for mounting small parts for processing  

DOE Patents (OSTI)

A fixture for mounting small parts, such as fusion target spheres or microelectronic components. A glass stalk is drawn and truncated near its tip. The truncated end of the glass stalk is dipped into silicone rubber forming an extending streamer. After the rubber cures for approximately 24 hours, a small part is touched to the streamer, and will be held securely throughout processing.

Foreman, Larry R. (2456 36th St., Los Alamos, NM 87544); Gomez, Veronica M. (Rte. 5 Box 283, Santa Fe, NM 87501); Thomas, Michael H. (Rte. 3-193-1, Espanola, NM 87532)

1990-01-01T23:59:59.000Z

28

Holding fixture for metallographic mount polishing  

DOE Patents (OSTI)

A fixture is described for holding mounted specimens for polishing, having an arm; a body attached to one end of the arm, the body having at least one flange having an opening to accommodate a mounted specimen; and a means applying pressure against the outer surface of the mounted specimen to hold the specimen in contact with the polishing surface. 3 figs.

Barth, C.H.; Cramer, C.E.

1997-12-30T23:59:59.000Z

29

Design of ultra precision fixtures for nano-manufacturing  

E-Print Network (OSTI)

This thesis presents the design, modeling, fabrication and experimental validation of an active precision fixturing system called the Hybrid Positioning Fixture (HPF). The HPF uses the principles of exact constraint, ...

Mangudi Varadarajan, Kartik, 1981-

2005-01-01T23:59:59.000Z

30

Operating temperatures of recessed fluorescent fixtures with thermal insulation  

SciTech Connect

Tests were performed to determine steady state surface temperatures for recessed fluorescent fixtures operated with and without thermal insulation on the top side of the fixture and to identify potential problems associated with the installation of thermal insulation. In addition to measuring temperatures, means were sought by which the fixtures can be thermally insulated and operated without fire hazards or damage to the fixture. (MCW)

Yarbrough, D.W.; Toor, I.A.

1981-05-01T23:59:59.000Z

31

GaN nanorod light emitting diodes with suspended graphene transparent electrodes grown by rapid chemical vapor deposition  

SciTech Connect

Ordered and dense GaN light emitting nanorods are studied with polycrystalline graphene grown by rapid chemical vapor deposition as suspended transparent electrodes. As the substitute of indium tin oxide, the graphene avoids complex processing to fill up the gaps between nanorods and subsequent surface flattening and offers high conductivity to improve the carrier injection. The as-fabricated devices have 32% improvement in light output power compared to conventional planar GaN-graphene diodes. The suspended graphene remains electrically stable up to 300?°C in air. The graphene can be obtained at low cost and high efficiency, indicating its high potential in future applications.

Xu, Kun; Xu, Chen, E-mail: xuchen58@bjut.edu.cn; Deng, Jun; Zhu, Yanxu; Guo, Weiling; Mao, Mingming; Xun, Meng; Chen, Maoxing; Zheng, Lei [Key Laboratory of Optoelectronics Technology, Beijing University of Technology, Ministry of Education, Beijing 100124 (China)] [Key Laboratory of Optoelectronics Technology, Beijing University of Technology, Ministry of Education, Beijing 100124 (China); Xie, Yiyang [State Key Laboratory of Integrated Optoelectronics, Institute of Semiconductor, Chinese Academy of Sciences, Beijing 100083 (China)] [State Key Laboratory of Integrated Optoelectronics, Institute of Semiconductor, Chinese Academy of Sciences, Beijing 100083 (China); Sun, Jie, E-mail: jie.sun@chalmers.se [Key Laboratory of Optoelectronics Technology, Beijing University of Technology, Ministry of Education, Beijing 100124 (China) [Key Laboratory of Optoelectronics Technology, Beijing University of Technology, Ministry of Education, Beijing 100124 (China); Mikroteknologi och Nanovetenskap, Chalmers Tekniska Högskola AB, Göteborg 41296 (Sweden)

2013-11-25T23:59:59.000Z

32

Sub-Doppler resonances in the back-scattered light from random porous media infused with Rb vapor  

E-Print Network (OSTI)

We report on the observation of sub-Doppler resonances on the back-scattered light from a random porous glass medium with rubidium vapor filling its interstices. The sub-Doppler spectral lines are the consequence of saturated absorption where the incident laser beam saturates the atomic medium and the back-scattered light probes it. Some specificities of the observed spectra reflect the transient atomic evolution under confinement inside the pores. Simplicity, robustness and potential miniaturization are appealing features of this system as a spectroscopic reference.

Villalba, S; Lenci, L; Bloch, D; Lezama, A; Failache, H

2013-01-01T23:59:59.000Z

33

Thermal resilient multiple jaw braze fixture  

DOE Patents (OSTI)

A braze fixture has side walls forming a cavity with an opening to receive a stack of parts to be brazed. Sidewalls of the housing have a plurality of bearing receiving openings into which bearing rods or jaws are inserted to align the stacked elements of the workpiece. The housing can also have view ports to allow a visual check of the alignment. Straps or wires around the fixture are selected to have thermal characteristics similar to the thermal characteristics of the workpiece undergoing brazing. The straps or wires make physical contact with the bearing rods thereby causing bearing rods to maintain the workpiece in proper alignment throughout the entire brazing cycle. 9 figs.

Ney, R.; Perrone, A.J.

1995-07-11T23:59:59.000Z

34

Fixture for mounting small parts for processing  

DOE Patents (OSTI)

A fixture for mounting small parts, such as fusion target spheres or microelectronic components is disclosed. A glass stalk is drawn and truncated near its tip. The truncated end of the glass stalk is dipped into silicone rubber forming an extending streamer. After the rubber cures for approximately 24 hours, a small part is touched to the streamer, and will be held securely throughout processing. 5 figs.

Foreman, L.R.; Gomez, V.M.; Thomas, M.H.

1990-05-29T23:59:59.000Z

35

Lighting | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

to installing LEDs in existing fixtures. Tips and Advice Tips: Lighting Lighting choices save you money. Energy-efficient light bulbs are available in a wide variety of sizes...

36

Chapter 6, Residential Lighting Evaluation Protocol: The Uniform...  

Office of Environmental Management (EM)

STAR lighting fixtures. More recently, programs are introducing solid-state light-emitting diode (LED) lamps. The future of savings claims from residential lighting programs is...

37

Integrated Calibration Sphere and Calibration Step Fixture for Improved  

NLE Websites -- All DOE Office Websites (Extended Search)

Integrated Calibration Sphere and Calibration Step Fixture for Integrated Calibration Sphere and Calibration Step Fixture for Improved Coordinate Measurement Machine Calibration Integrated Calibration Sphere and Calibration Step Fixture for Improved Coordinate Measurement Machine Calibration A method and apparatus for mounting a calibration sphere to a calibration fixture for Coordinate Measurement Machine (CMM) calibration and qualification is described, decreasing the time required for such qualification, thus allowing the CMM to be used more productively. Available for thumbnail of Feynman Center (505) 665-9090 Email Integrated Calibration Sphere and Calibration Step Fixture for Improved Coordinate Measurement Machine Calibration A method and apparatus for mounting a calibration sphere to a calibration fixture for Coordinate Measurement Machine (CMM) calibration and

38

Reading Municipal Light Department - Business Lighting Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Reading Municipal Light Department - Business Lighting Rebate Reading Municipal Light Department - Business Lighting Rebate Program Reading Municipal Light Department - Business Lighting Rebate Program < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Schools State Government Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Commercial Customers: $10,000 per calendar year Municipal Customers: $15,000 per calendar year Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount T-8/T-5 Lamp with Electronic Ballasts: $11 - $35/fixture Interior High Output Lamp with Electronic Ballasts: $100/fixture De-lamping: $4 - $9/lamp Lighting Sensors: $20/sensor LED Exit Signs: $20/fixture Provider Incentive Programs

39

Regional coordination of the ENERGY STAR{reg{underscore}sign} residential fixture program: Design, implementation, and early observations  

SciTech Connect

The Northwest Energy Efficiency Alliance and a group of California utilities are implementing a unique market transformation initiative to promote the use of energy-efficient residential light fixtures. This effort is based on the current ENERGY STAR{reg{underscore}sign} specification for residential fixtures, and combines manufacturer rebates with aggressive education and marketing efforts in order to stimulate increased sales of these products. The initiative was developed in 1997, and has been underway in Idaho, Montana, Oregon, Washington, and California since early 1998. Program efforts are designed to increase the availability of qualified fixtures in the retail and electric wholesale channels throughout the five-state area, and to stimulate direct sales to large homebuilders active in the region. An RFP process was used to select six lighting manufacturers, who are now eligible to receive rebate payments of $7 to $10 for each qualified fixture shipped during 1998. A similar process will be employed in late 1998 to select the eligible manufacturers for 1999. As of May 1998, participating manufacturers have shipped over 37,000 qualifying fixtures throughout the five states covered by the program, with most units being delivered to retain stores such as Home Depot, Home Base, Eagle Hardware and Garden, and Costco. These shipments represent 10% of the 1998 program goal.

Moore, J.; Gordon, L.; Latham, L.

1998-07-01T23:59:59.000Z

40

Near optimal design of fixture layouts in multi-station assembly processes  

E-Print Network (OSTI)

This dissertation presents a methodology for the near optimal design of fixture layouts in multi-station assembly processes. An optimal fixture layout improves the robustness of a fixture system, reduces product variability and leads...

Kim, Pansoo

2004-11-15T23:59:59.000Z

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Processor and method for developing a set of admissible fixture designs for a workpiece  

DOE Patents (OSTI)

Methods and apparatus are provided for developing a complete set of all admissible Type 1 and Type 2 fixture designs for a workpiece. The fixture processor generates the set of all admissible designs based on geometric access constraints and expected applied forces on the workpiece. For instance, the fixture processor may generate a set of admissible fixture designs for first, second and third locators placed in an array of holes on a fixture plate and a translating clamp attached to the fixture plate for contacting the workpiece. In another instance, a fixture vise is used in which first, second, third and fourth locators are used and first and second fixture jaws are tightened to secure the workpiece. The fixture process also ranks the set of admissible fixture designs according to a predetermined quality metric so that the optimal fixture design for the desired purpose may be identified from the set of all admissible fixture designs. 44 figs.

Brost, R.C.; Goldberg, K.Y.; Canny, J.; Wallack, A.S.

1999-01-05T23:59:59.000Z

42

Marine Corps Base Quantico Achieves 85% Savings in Parking Lighting...  

Office of Environmental Management (EM)

by conducting a major overhaul of its outdoor lighting (replacing 2,000 fixtures with LED lights), while boosting safety and security throughout the site. mcbquantico2014.pdf...

43

Fluorescent Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fluorescent Lighting Fluorescent Lighting Fluorescent Lighting October 17, 2013 - 5:44pm Addthis Fluorescent Lighting Fluorescent Lighting Fluorescent lamps use 25%-35% of the energy used by incandescent products to provide a similar amount of light. They also last about 10 times longer (7,000-24,000 hours). The two general types of fluorescent lamps are: Compact fluorescent lamps (CFLs) -- commonly found with integral ballasts and screw bases, these are popular lamps often used in household fixtures Fluorescent tube and circline lamps -- typically used for task lighting such as garages and under cabinet fixtures, and for lighting large areas in commercial buildings. CFLs CFLs combine the energy efficiency of fluorescent lighting with the convenience and popularity of incandescent fixtures. CFLs fit most fixtures

44

LIGHTING RESEARCH PROGRAM Project 4.2 The ENERGY STAR Residential Light  

E-Print Network (OSTI)

LIGHTING RESEARCH PROGRAM Project 4.2 The ENERGY STAR® Residential Light Fixture Advancement Report Applied Proactive Technologies/Architectural Energy Corporation PIER Lighting Research Program 2 Applied Proactive Technologies/Architectural Energy Corporation PIER Lighting Research Program 3 500

45

Redesign of Lighting Fixtures for the Texas Department of Corrections  

E-Print Network (OSTI)

that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation... is considered necessary. Implementation of these recommendations will result in reduced construction cost of $91,418 and annual operating savings of $88,910 if recommendations 1-5 and 6a are implemented at Amarillo and Gatesville. Use of recommendations 1...

Claridge, D. E.; Turner, W. D.; Krarti, M.; Yebra, R.

1988-01-01T23:59:59.000Z

46

Welding fixture for nuclear fuel pin cladding assemblies  

DOE Patents (OSTI)

A welding fixture for locating a driver sleeve about the open end of a nuclear fuel pin cladding. The welding fixture includes a holder provided with an open cavity having shoulders for properly positioning the driver sleeve, the end cap, and a soft, high temperature resistant plastic protective sleeve that surrounds a portion of the end cap stem. Ejected contaminant particles spewed forth by closure of the cladding by pulsed magnetic welding techniques are captured within a contamination trap formed in the holder for ultimate removal and disposal of contaminating particles along with the holder.

Oakley, David J. (Richland, WA); Feld, Sam H. (West Richland, WA)

1986-01-01T23:59:59.000Z

47

Turbo-Charged Lighting Design  

E-Print Network (OSTI)

TURBO-CHARGED LIGHTING DESIGN William H. Clark II Design Engineer O'Connell Robertson & Assoc Austin/ Texas ABSTRACT The task of the lighting designer has become very complex, involving thousands of choices for fixture types and hundreds... at this point. will read the data into the lighting file and clear the screen for the next calculation. The designer has access to over one hundred fixture types (expandable indefinitely). The most useful ones are displayed on the screen. The balance...

Clark, W. H. II

48

High pressure/high temperature vapor liquid equilibrium study of light gases in hydrogen-coal liquid model compound systems using perturbation chromatography  

SciTech Connect

Perturbation chromatography or gas-liquid partition chromatography (GLPC) provides a powerful tool for making physicochemical measurements. In this investigation GLPC was applied to study the vapor-liquid equilibrium behavior of light gases in nonvolatile coal liquid model compound solvents at high temperatures and high pressures. Improvements made in existing GLPC techniques include: the use of a high pressure tandem proportioning pump to give precise control of the carrier gas flow rate and low pressure drops; a high pressure ionization chamber to detect the injection of very dilute radioactive sample gases; and the use of a microcomputer to provide instantaneous integration and very precise retention times of the chromatographic peaks. Infinite dilution K-values for methane, ethane, propane, n-butane, carbon dioxide, and hydrogen sulfide in hydrogen-dibenzofuran systems were obtained at 100 and 125 C and up to 800 psia. Infinite dilution K-values for the same light gases in hydrogen-9-methylanthracene systems were obtained at 100, 125, 150, 175, and 200 C and up to 3000 psia. Henry's constants were determined for the light gases in 9-methylanthracene. Second cross virial coefficients and vapor phase infinite dilution fugacity coefficients were calculated for methane, ethane, propane, and n-butane in hydrogen. These results were combined with the experimental K-value measurements to obtain Henry's constants in hydrogen-9-methylanthracene mixtures of fixed liquid compositions. Infinite dilution heats of solution of the solute gases in the mixtures were calculated.

Kragas, T.K.

1983-01-01T23:59:59.000Z

49

EECBG Success Story: Lighting Retrofit Improving Visibility,...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Retrofit Improving Visibility, Saving Energy August 27, 2010 - 10:05am Addthis New LED lighting fixtures (right) emit a whiter light than existing high-pressure sodium cobra...

50

Lighting Research Group: Facilities: Goniometer  

NLE Websites -- All DOE Office Websites (Extended Search)

Goniometer Goniometer gonio-photometer Gonio-Photometer Gonio-photometer | Integrating sphere | Power analyzer | Spectro-radiometer The gonio-photometer (or goniometer for short) is able to measure the illuminance from each portion of a lamp or fixture. There are three main components to the goniometer: (1) the rotating table that the fixture or lamp is placed on, (2) the long arm with a mirror on the end that rotates around the fixture and (3) a light sensor that measures the light reflected by the mirror. The light source (whether it is in a fixture or not) is placed in the middle of the goniometer, sitting on the rotating table. The rotating table can be adjusted up and down to make sure that the light source is in the very center of the goniometer. When the lamp is positioned this way, the

51

Lighting system combining daylight concentrators and an artificial source  

DOE Patents (OSTI)

A combined lighting system for a building interior includes a stack of luminescent solar concentrators (LSC), an optical conduit made of preferably optical fibers for transmitting daylight from the LSC stack, a collimating lens set at an angle, a fixture for receiving the daylight at one end and for distributing the daylight as illumination inside the building, an artificial light source at the other end of the fixture for directing artifical light into the fixture for distribution as illumination inside the building, an automatic dimmer/brightener for the artificial light source, and a daylight sensor positioned near to the LSC stack for controlling the automatic dimmer/brightener in response to the daylight sensed. The system also has a reflector positioned behind the artificial light source and a fan for exhausting heated air out of the fixture during summer and for forcing heated air into the fixture for passage into the building interior during winter.

Bornstein, Jonathan G. (Miami, FL); Friedman, Peter S. (Toledo, OH)

1985-01-01T23:59:59.000Z

52

Near real time vapor detection and enhancement using aerosol adsorption  

SciTech Connect

A vapor sample detection method where the vapor sample contains vapor and ambient air and surrounding natural background particles. The vapor sample detection method includes the steps of generating a supply of aerosol that have a particular effective median particle size, mixing the aerosol with the vapor sample forming aerosol and adsorbed vapor suspended in an air stream, impacting the suspended aerosol and adsorbed vapor upon a reflecting element, alternatively directing infrared light to the impacted aerosol and adsorbed vapor, detecting and analyzing the alternatively directed infrared light in essentially real time using a spectrometer and a microcomputer and identifying the vapor sample.

Novick, Vincent J.; Johnson, Stanley A.

1997-12-01T23:59:59.000Z

53

Near real time vapor detection and enhancement using aerosol adsorption  

DOE Patents (OSTI)

A vapor sample detection method is described where the vapor sample contains vapor and ambient air and surrounding natural background particles. The vapor sample detection method includes the steps of generating a supply of aerosol that have a particular effective median particle size, mixing the aerosol with the vapor sample forming aerosol and adsorbed vapor suspended in an air stream, impacting the suspended aerosol and adsorbed vapor upon a reflecting element, alternatively directing infrared light to the impacted aerosol and adsorbed vapor, detecting and analyzing the alternatively directed infrared light in essentially real time using a spectrometer and a microcomputer and identifying the vapor sample. 13 figs.

Novick, V.J.; Johnson, S.A.

1999-08-03T23:59:59.000Z

54

Near real time vapor detection and enhancement using aerosol adsorption  

DOE Patents (OSTI)

A vapor sample detection method where the vapor sample contains vapor and ambient air and surrounding natural background particles. The vapor sample detection method includes the steps of generating a supply of aerosol that have a particular effective median particle size, mixing the aerosol with the vapor sample forming aerosol and adsorbed vapor suspended in an air stream, impacting the suspended aerosol and adsorbed vapor upon a reflecting element, alternatively directing infrared light to the impacted aerosol and adsorbed vapor, detecting and analyzing the alternatively directed infrared light in essentially real time using a spectrometer and a microcomputer and identifying the vapor sample.

Novick, Vincent J. (Downers Grove, IL); Johnson, Stanley A. (Countryside, IL)

1999-01-01T23:59:59.000Z

55

E-Print Network 3.0 - automated fixture layout Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Individual Dissertation (G53IDS) Summary: than fixtures per day). Before designing any interface layouts I decided to conduct research... Automated Scheduling of Sport...

56

Energy - LEDs to light UT arena | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

to 85 percent more efficient than conventional arena metal halide lights. The light-emitting diode fixtures developed by Oak Ridge-based LED North America incorporate an Oak...

57

All mercury lamps contain small amounts of mercury. An electric current passes through the lamp and vaporizes the mercury to generate light. Recycling mercury containing lamps protects human health and our environment from heavy  

E-Print Network (OSTI)

All mercury lamps contain small amounts of mercury. An electric current passes through the lamp and vaporizes the mercury to generate light. Recycling mercury containing lamps protects human health and our the environment by recycling universal wastes, contact EH&S at (949) 824-6200 or visit: www.ehs.uci.edu Mercury

George, Steven C.

58

Solid-State Lighting Manufacturing Workshop  

Energy.gov (U.S. Department of Energy (DOE))

Nearly 200 lighting industry leaders, chip makers, fixture and component manufacturers, and others gathered in Fairfax, Virginia, on April 21 and 22, 2009, for the first-ever DOE Solid-State...

59

Street light holography  

Science Journals Connector (OSTI)

The production of a hologram is demonstrated using only a camera aluminum foil and a mercury vapor street light.

R. R. Turtle

1977-01-01T23:59:59.000Z

60

Lighting and Daylighting Products and Services | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting and Daylighting Products and Services Lighting and Daylighting Products and Services Lighting and Daylighting Products and Services July 29, 2012 - 5:06pm Addthis Lighting and Daylighting Products and Services Use the following links to get product information and locate professional services for lighting and daylighting. Product Information Advanced Lighting Package ENERGY STAR® Information on the ENERGY STAR Advanced Lighting Project, which allows homeowners to upgrade their light fixtures to more energy efficient products. Energy-efficient Lights ENERGY STAR® Information on the benefits of ENERGY STAR qualified light bulbs. Fixtures Guide ENERGY STAR® Examples and pictures of ENERGY STAR qualified light fixtures. How to Select Residential LED Under-cabinet Lighting (PDF) Alliance for Solid-State Illumination Systems and Technologies

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Lighting and Daylighting Products and Services | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting and Daylighting Products and Services Lighting and Daylighting Products and Services Lighting and Daylighting Products and Services July 29, 2012 - 5:06pm Addthis Lighting and Daylighting Products and Services Use the following links to get product information and locate professional services for lighting and daylighting. Product Information Advanced Lighting Package ENERGY STAR® Information on the ENERGY STAR Advanced Lighting Project, which allows homeowners to upgrade their light fixtures to more energy efficient products. Energy-efficient Lights ENERGY STAR® Information on the benefits of ENERGY STAR qualified light bulbs. Fixtures Guide ENERGY STAR® Examples and pictures of ENERGY STAR qualified light fixtures. How to Select Residential LED Under-cabinet Lighting (PDF) Alliance for Solid-State Illumination Systems and Technologies

62

Integrated calibration sphere and calibration step fixture for improved coordinate measurement machine calibration  

DOE Patents (OSTI)

A method and apparatus for mounting a calibration sphere to a calibration fixture for Coordinate Measurement Machine (CMM) calibration and qualification is described, decreasing the time required for such qualification, thus allowing the CMM to be used more productively. A number of embodiments are disclosed that allow for new and retrofit manufacture to perform as integrated calibration sphere and calibration fixture devices. This invention renders unnecessary the removal of a calibration sphere prior to CMM measurement of calibration features on calibration fixtures, thereby greatly reducing the time spent qualifying a CMM.

Clifford, Harry J. (Los Alamos, NM)

2011-03-22T23:59:59.000Z

63

On the development of a universal automated fixturing system through encapsulation techniques  

E-Print Network (OSTI)

Universal automated fixturing can transform a machine tool into a rapid prototyping machine with many advantages over current rapid prototyping methods. Using this modified machine tool, prototype parts can be manufactured ...

Lee, Elmer C., 1973-

2001-01-01T23:59:59.000Z

64

Cost Savings and Energy Reduction: Bi-Level Lighting Retrofits in Multifamily Buildings  

E-Print Network (OSTI)

Community Environmental Center implements Bi- Level Lighting fixtures as a component of cost-effective multifamily retrofits. These systems achieve substantial energy savings by automatically reducing lighting levels when common areas are unoccupied...

Ackley, J.

2010-01-01T23:59:59.000Z

65

Coldwater Board of Public Utilities - Commercial and Industrial Lighting  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Coldwater Board of Public Utilities - Commercial and Industrial Coldwater Board of Public Utilities - Commercial and Industrial Lighting Rebate Program Coldwater Board of Public Utilities - Commercial and Industrial Lighting Rebate Program < Back Eligibility Commercial Industrial Local Government Multi-Family Residential Nonprofit Savings Category Other Appliances & Electronics Commercial Lighting Lighting Manufacturing Heating & Cooling Commercial Heating & Cooling Cooling Buying & Making Electricity Maximum Rebate 50% of Project Cost Cannot exceed 100% of a single energy efficient measure's cost. Program Info State Michigan Program Type Utility Rebate Program Rebate Amount Custom: Not Specified Lighting Fluorescent Lighting: $2 - $50/fixture HID Lighting: $20 - $25/fixture Induction Bulb: $10 Metal Halide PAR Bulb: $20

66

NINTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE  

SciTech Connect

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT O-ring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 72 - 96 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 54 - 57 months. No additional O-ring failures have been observed since the last interim report was issued. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures is recommended to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.

Daugherty, W.

2014-08-06T23:59:59.000Z

67

FirstEnergy (Potomac Edison) - Municipal and Street Lighting Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

FirstEnergy (Potomac Edison) - Municipal and Street Lighting FirstEnergy (Potomac Edison) - Municipal and Street Lighting Program (Maryland) FirstEnergy (Potomac Edison) - Municipal and Street Lighting Program (Maryland) < Back Eligibility Commercial Industrial Institutional Local Government Nonprofit Schools State Government Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info State Maryland Program Type Utility Rebate Program Rebate Amount '''Street Lighting'''br/> High Pressure Sodium Fixtures: $10 - $50/unit LED/Induction Fixtures: $50 '''Traffic/Pedestrian Signals''' Lamp/Signal/Arrows: $35/unit Provider FirstEnergy (Potomac Edison) FirstEnergy offers several incentives for non-residential and municipal customers to upgrade traffic signals, pedestrian signals, street lights to more efficient fixtures. The Municipal Lighting Incentive Program offers

68

SIXTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE  

SciTech Connect

A series of experiments to monitor the aging performance of Viton{reg_sign} GLT O-rings used in the Model 9975 package has been ongoing for seven years at the Savannah River National Laboratory. Seventy tests using mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested periodically to determine if they meet the criterion of leak-tightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues for 33 GLT O-ring fixtures at 200-300 F. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 F and higher temperatures, and in 7 fixtures aging at 300 F. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 41-60 months, which is still bounding to O-ring temperatures during storage in K-Area Complex (KAC). Based on expectations that the fixtures aging at 200 F will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging within the past year at an intermediate temperature of 270 F, with hopes that they may leak before the 200 F fixtures. High temperature aging continues for 6 GLT-S O-ring fixtures at 200-300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200-300 F for up to 26 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the Orings displayed a compression set ranging from 51-96%. This is greater than seen to date for packages inspected during KAC field surveillance (24% average). For GLT O-rings, separate service life estimates have been made based on the O-ring fixture leak test data and based on compression stress relaxation (CSR) data. These two predictive models show reasonable agreement at higher temperatures (350-400 F). However, at 300 F, the room temperature leak test failures to date experienced longer aging times than predicted by the CSR-based model. This suggests that extrapolations of the CSR model predictions to temperatures below 300 F will provide a conservative prediction of service life relative to the leak rate criterion. Leak test failure data at lower temperatures are needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining fixtures.

Daugherty, W.

2011-08-31T23:59:59.000Z

69

Solid-State Lighting: Solid-State Lighting Videos  

NLE Websites -- All DOE Office Websites (Extended Search)

Solid-State Lighting Videos to Solid-State Lighting Videos to someone by E-mail Share Solid-State Lighting: Solid-State Lighting Videos on Facebook Tweet about Solid-State Lighting: Solid-State Lighting Videos on Twitter Bookmark Solid-State Lighting: Solid-State Lighting Videos on Google Bookmark Solid-State Lighting: Solid-State Lighting Videos on Delicious Rank Solid-State Lighting: Solid-State Lighting Videos on Digg Find More places to share Solid-State Lighting: Solid-State Lighting Videos on AddThis.com... Conferences & Meetings Presentations Publications Webcasts Videos Tools Solid-State Lighting Videos On this page you can access DOE Solid-State Lighting (SSL) Program videos. Photo of a museum art gallery with LED lights in track fixtures overhead. The City of Los Angeles LED Streetlight Program

70

FIFTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE  

SciTech Connect

A series of experiments to monitor the aging performance of Viton{reg_sign} GLT O-rings used in the Model 9975 package has been ongoing for six years at the Savannah River National Laboratory. Sixty-seven mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested at nominal six month intervals to determine if they meet the criterion of leaktightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues for 36 GLT O-ring fixtures at 200-350 F. Room temperature leak test failures have been experienced in 6 of the GLT O-ring fixtures aging at 300 and 350 F, and in all 3 of the GLT O-ring fixtures aging at higher temperatures. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 30-48 months, which is still bounding to O-ring temperatures during storage in KAMS. High temperature aging continues for 6 GLT-S O-ring fixtures at 200-300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 or 300 F for 19 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the Orings displayed a compression set ranging from 51-95%. This is significantly greater than seen to date for packages inspected during KAMS field surveillance (23% average). For GLT O-rings, service life based on the room temperature leak rate criterion is comparable to that predicted by compression stress relaxation (CSR) data at higher temperatures (350-400 F). While there are no comparable failure data yet at aging temperatures below 300 F, extrapolations of the data for GLT O-rings suggests the CSR model predictions provide a conservative prediction of service life relative to the leak rate criterion. Failure data at lower temperatures are needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining fixtures.

Daugherty, W.; Hoffman, E.

2011-04-11T23:59:59.000Z

71

FIFTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE  

SciTech Connect

A series of experiments to monitor the aging performance of Viton{sup reg.} GLT O-rings used in the Model 9975 package has been ongoing for six years at the Savannah River National Laboratory. Sixty-seven mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested at nominal six month intervals to determine if they meet the criterion of leaktightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues for 36 GLT O-ring fixtures at 200--350 F. Room temperature leak test failures have been experienced in 5 of the GLT O-ring fixtures aging at 300 and 350 F, and in all 3 of the GLT O-ring fixtures aging at higher temperatures. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 30--48 months, which is still bounding to O-ring temperatures during storage in KAMS. High temperature aging continues for 6 GLT-S O-ring fixtures at 200--300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 or 300 F for 19 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the O-rings displayed a compression set ranging from 51--95%. This is significantly greater than seen to date for packages inspected during KAMS field surveillance (23% average). For GLT O-rings, service life based on the room temperature leak rate criterion is comparable to that predicted by compression stress relaxation (CSR) data at higher temperatures (350--400 F). While there are no comparable failure data yet at aging temperatures below 300 F, extrapolations of the data for GLT O-rings suggests that CSR model predictions provide a conservative prediction of service life relative to the leak rate criterion. Failure data at lower temperatures is needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining fixtures.

Daugherty, W.; Hoffman, E.

2010-11-01T23:59:59.000Z

72

Data:D32b9210-612f-484b-888b-4eb9cb43e3da | Open Energy Information  

Open Energy Info (EERE)

612f-484b-888b-4eb9cb43e3da 612f-484b-888b-4eb9cb43e3da No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-400 W SV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

73

Data:B1abc200-9467-4663-ad52-ef845d920429 | Open Energy Information  

Open Energy Info (EERE)

abc200-9467-4663-ad52-ef845d920429 abc200-9467-4663-ad52-ef845d920429 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-100 W MV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

74

Data:9b11a6a4-b93e-48bf-8860-1d22715f115f | Open Energy Information  

Open Energy Info (EERE)

-b93e-48bf-8860-1d22715f115f -b93e-48bf-8860-1d22715f115f No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-400 W MV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

75

Solid-State Lighting: Solid-State Lighting Manufacturing Workshop  

NLE Websites -- All DOE Office Websites (Extended Search)

Solid-State Lighting Solid-State Lighting Manufacturing Workshop to someone by E-mail Share Solid-State Lighting: Solid-State Lighting Manufacturing Workshop on Facebook Tweet about Solid-State Lighting: Solid-State Lighting Manufacturing Workshop on Twitter Bookmark Solid-State Lighting: Solid-State Lighting Manufacturing Workshop on Google Bookmark Solid-State Lighting: Solid-State Lighting Manufacturing Workshop on Delicious Rank Solid-State Lighting: Solid-State Lighting Manufacturing Workshop on Digg Find More places to share Solid-State Lighting: Solid-State Lighting Manufacturing Workshop on AddThis.com... Conferences & Meetings Past Conferences Presentations Publications Webcasts Videos Tools Solid-State Lighting Manufacturing Workshop Nearly 200 lighting industry leaders, chip makers, fixture and component

76

Smart Lighting: A Second Wave in Solid State Lighting?  

E-Print Network (OSTI)

is Smart Lighting? · A Second Wave? #12;Bulbs transition to..... Bulbs! 3 · Sockets exist, so why not use them? (faster revenue, energy savings) · LED sources are mostly lower brightness · LED idiosyncrasies make broad incandescent and fluorescent replacement difficult ­ new fixtures coming First Wave #12

Salama, Khaled

77

Seattle City Light - Built Smart Program for Builders and Architects |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Seattle City Light - Built Smart Program for Builders and Seattle City Light - Built Smart Program for Builders and Architects Seattle City Light - Built Smart Program for Builders and Architects < Back Eligibility Construction Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Other Sealing Your Home Design & Remodeling Windows, Doors, & Skylights Ventilation Heat Pumps Commercial Lighting Lighting Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount Windows: $0.39 - $1.55/sq. ft. Ceiling Insulation: $0.12-$0.23/sq. ft. Wall Insulation: $0.08 - $0.41/sq. ft. Slab Insulation: $0.13/sq. ft. Exterior Common Area Lighting Fixtures: $30/fixture Interior Common Area Lighting Fixtures: $0.20/first year kWh savings

78

Lighting  

SciTech Connect

The lighting section of ASHRAE standard 90.1 is discussed. It applies to all new buildings except low-rise residential, while excluding specialty lighting applications such as signage, art exhibits, theatrical productions, medical and dental tasks, and others. In addition, lighting for indoor plant growth is excluded if designed to operate only between 10 p.m. and 6 a.m. Lighting allowances for the interior of a building are determined by the use of the system performance path unless the space functions are not fully known, such as during the initial stages of design or for speculative buildings. In such cases, the prescriptive path is available. Lighting allowances for the exterior of all buildings are determined by a table of unit power allowances. A new addition the exterior lighting procedure is the inclusion of facade lighting. However, it is no longer possible to trade-off power allotted for the exterior with the interior of a building or vice versa. A significant change is the new emphasis on lighting controls.

McKay, H.N. (Hayden McKay Lighting Design, New York, NY (US))

1990-02-01T23:59:59.000Z

79

Poudre Valley REA - Commercial Lighting Rebate Program (Colorado) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Lighting Rebate Program (Colorado) Commercial Lighting Rebate Program (Colorado) Poudre Valley REA - Commercial Lighting Rebate Program (Colorado) < Back Eligibility Commercial Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Commercial Lighting Retrofit: 50% of equipment cost, $20,000 LED Street Lighting/Induction Street Lighting: $20,000 Program Info State Colorado Program Type Utility Rebate Program Rebate Amount LED Refrigerated Case Lighting (Top Lighting): $60 per ln ft LED Refrigerated Case Lighting (Case Lighting): $60 per door LED Street Lighting: $44 - $475 per fixture Induction Street Lighting: $33 - $355 per fixture Commercial Lighting Retrofit: $250 per kW saved Provider Poudre Valley REA Poudre Valley Rural Electric Association (PVREA), a Touchstone Energy

80

Estimate of federal relighting potential and demand for efficient lighting products  

SciTech Connect

The increasing level of electric utility rebates for energy-efficient lighting retrofits has recently prompted concern over the adequacy of the market supply of energy-efficient lighting products (Energy User News 1991). In support of the U.S. Department of Energy`s Federal Energy Management Program, Pacific Northwest Laboratory (PNL) has developed an estimate of the total potential for energy-efficient lighting retrofits in federally owned buildings. This estimate can be used to address the issue of the impact of federal relighting projects on the supply of energy-efficient lighting products. The estimate was developed in 1992, using 1991 data. Any investments in energy-efficient lighting products that occurred in 1992 will reduce the potential estimated here. This analysis proceeds by estimating the existing stock of lighting fixtures in federally owned buildings. The lighting technology screening matrix is then used to determine the minimum life-cycle cost retrofit for each type of existing lighting fixture. Estimates of the existing stock are developed for (1) four types of fluorescent lighting fixtures (2-, 3-, and 4-lamp, F40 4-foot fixtures, and 2-lamp, F96 8-foot fixtures, all with standard magnetic ballasts); (2) one type of incandescent fixture (a 75-watt single bulb fixture); and (3) one type of exit sign (containing two 20-watt incandescent bulbs). Estimates of the existing stock of lighting fixtures in federally owned buildings, estimates of the total potential demand for energy-efficient lighting products if all cost-effective retrofits were undertaken immediately, and total potential annual energy savings (in MWh and dollars), the total investment required to obtain the energy savings and the present value of the efficiency investment, are presented.

Shankle, S.A.; Dirks, J.A.; Elliott, D.B.; Richman, E.E.; Grover, S.E.

1993-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Data:93fa20c8-fba6-4cfa-9665-41e450f96d0a | Open Energy Information  

Open Energy Info (EERE)

Vapor 175 Watt (24 Foot pole) Sector: Lighting Description: *Traditional Fixture with 24 Foot Fiberglass pole. All Decorative Lighting is subject to a ten year minimum contract...

82

Data:C0ad9b1a-3011-4536-a95a-96ef0c42f10e | Open Energy Information  

Open Energy Info (EERE)

End date if known: Rate name: Security Lighting- Decorative- Mercury Vapor 175 Watt (15 Foot pole) Sector: Lighting Description: *Traditional Fixture with 15 Foot Fiberglass...

83

Kansas City Power and Light - Commercial/Industrial Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4,907-$35,142 by business 4,907-$35,142 by business class size and differs among Missouri and Kansas residents. Program Info State Kansas Program Type Utility Rebate Program Rebate Amount Energy Audit ( Energy Audit (> 25,000 sq ft): 50% of cost, up to $500 High Performance T8 Fixtures: $20 - $30/fixture Standard T8 Lamps/Ballasts: $2 - $10/unit Lighting Power Density: $1/watt per square foot High Intensity Fluorescent: $50/fixture Pulse Star Metal Halide: $50/fixture Lighting Controls: $20 - $50 per sensor Single Phase Package/Split System AC: $92/ton Three Phase Unitary/Split System AC: $92/ton Unitary/Split System AC: $73 - $79/ton Motors: $50 - $130/motor Custom (Retrofit): The lesser of a buydown to a two year payback, or 50% of the incremental cost Custom (New Construction): The lesser of a buydown to a two year payback,

84

Kansas City Power and Light - Commercial/Industrial Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7,299-$52,276 by business 7,299-$52,276 by business class, size, new construction, retrofit, and location. Program Info State Missouri Program Type Utility Rebate Program Rebate Amount Energy Audit ( Energy Audit (> 25,000 sq ft): 50% of cost, up to $500 High Performance T8 Fixtures: $20 - $30/fixture Standard T8 Lamps/Ballasts: $2 - $10/unit Lighting Power Density: $1/watt per square foot High Intensity Fluorescent: $50/fixture Pulse Star Metal Halide: $50/fixture Lighting Controls: $20 - $50 per sensor Single Phase Package/Split System AC: $92/ton Three Phase Unitary/Split System AC: $92/ton Unitary/Split System AC: $73 - $79/ton Motors: $50 - $130/motor Custom (Retrofit): The lesser of a buydown to a two year payback, or 50% of the incremental cost Custom (New Construction): The lesser of a buydown to a two year payback,

85

Probabilistic Algorithms for Efficient Grasping and Fixturing Marek Teichmann \\Lambda Bud Mishra y  

E-Print Network (OSTI)

into a collection of convex set covering problems where we either minimize the cover size or maximize the scaling polytopes and balls. The framework generalizes an algorithm for polytope covering and approximationProbabilistic Algorithms for Efficient Grasping and Fixturing Marek Teichmann \\Lambda Bud Mishra y

Mishra, Bud

86

Safety Slides Rota/ng Sha3s AR-G2 Coue;e Fixture  

E-Print Network (OSTI)

Safety Slides ­ Rota/ng Sha3s 1 AR-G2 Coue;e Fixture · loose-fi@ng shirts max = 250 to 300 rad/s #12;Safety Slides ­ Rota/ng Sha3s 2 Pinch Points in Rota

Cohen, Robert E.

87

Model-Based Telerobotic Control with Virtual Fixtures For Satellite Servicing Tasks  

E-Print Network (OSTI)

the tape that secures a flap of multi-layer insulation over the access panel of a satellite mockup. I its national capability to perform on- orbit repair of satellites in low-earth orbit, and evenModel-Based Telerobotic Control with Virtual Fixtures For Satellite Servicing Tasks Tian Xia, Simon

Whitcomb, Louis L.

88

National Ignition Facility computational fluid dynamics modeling and light fixture case studies  

SciTech Connect

This report serves as a guide to the use of computational fluid dynamics (CFD) as a design tool for the National Ignition Facility (NIF) program Title I and Title II design phases at Lawrence Livermore National Laboratory. In particular, this report provides general guidelines on the technical approach to performing and interpreting any and all CFD calculations. In addition, a complete CFD analysis is presented to illustrate these guidelines on a NIF-related thermal problem.

Martin, R.; Bernardin, J.; Parietti, L.; Dennison, B.

1998-02-01T23:59:59.000Z

89

Automated fixture and robot-aided deburring for light aircraft components.  

E-Print Network (OSTI)

??Bristol Aerospace Limited (BAL), Winnipeg, manufactures a wide range of parts for the Boeing-777 aircraft. Most of these parts have cubic edges and cubic surfaces… (more)

Pandian, Jayasundaram

1998-01-01T23:59:59.000Z

90

Marine Corps Base Quantico Achieves 85% Savings in Parking Lighting  

Energy.gov (U.S. Department of Energy (DOE))

Document provides an overview of how the Marine Corps Base Quantico (MCBQ) achieved 85% energy savings in parking lighting by conducting a major overhaul of its outdoor lighting (replacing 2,000 fixtures with LED lights), while boosting safety and security throughout the site.

91

Recommendations to Reduce Light Pollution and Energy Costs on the  

E-Print Network (OSTI)

Recommendations to Reduce Light Pollution and Energy Costs on the Campus of Bishop's University BU or longer), again listed in order of priority: · Replace class #9 lighting fixtures with more energy;Table of Contents Campus Lighting Efficiency Recommendations1 I. Cost Effective within 1 Year II. Cost

92

Diode pumped alkali vapor fiber laser  

DOE Patents (OSTI)

A method and apparatus is provided for producing near-diffraction-limited laser light, or amplifying near-diffraction-limited light, in diode pumped alkali vapor photonic-band-gap fiber lasers or amplifiers. Laser light is both substantially generated and propagated in an alkali gas instead of a solid, allowing the nonlinear and damage limitations of conventional solid core fibers to be circumvented. Alkali vapor is introduced into the center hole of a photonic-band-gap fiber, which can then be pumped with light from a pump laser and operated as an oscillator with a seed beam, or can be configured as an amplifier.

Payne, Stephen A. (Castro Valley, CA); Beach, Raymond J. (Livermore, CA); Dawson, Jay W. (Livermore, CA); Krupke, William F. (Pleasanton, CA)

2006-07-26T23:59:59.000Z

93

Diode pumped alkali vapor fiber laser  

DOE Patents (OSTI)

A method and apparatus is provided for producing near-diffraction-limited laser light, or amplifying near-diffraction-limited light, in diode pumped alkali vapor photonic-band-gap fiber lasers or amplifiers. Laser light is both substantially generated and propagated in an alkali gas instead of a solid, allowing the nonlinear and damage limitations of conventional solid core fibers to be circumvented. Alkali vapor is introduced into the center hole of a photonic-band-gap fiber, which can then be pumped with light from a pump laser and operated as an oscillator with a seed beam, or can be configured as an amplifier.

Payne, Stephen A. (Castro Valley, CA); Beach, Raymond J. (Livermore, CA); Dawson, Jay W. (Livermore, CA); Krupke, William F. (Pleasanton, CA)

2007-10-23T23:59:59.000Z

94

Peninsula Light Company - Commercial Efficient Lighting Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Peninsula Light Company - Commercial Efficient Lighting Rebate Peninsula Light Company - Commercial Efficient Lighting Rebate Program Peninsula Light Company - Commercial Efficient Lighting Rebate Program < Back Eligibility Commercial Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount General: 30% - 70% of cost Provider Peninsula Light Company Peninsula Light Company (PLC) offers a rebate program for commercial customers who wish to upgrade to energy efficient lighting. Participating customers must be served by PLC commercial service. Customers who upgrade to highly efficient fixtures and systems are eligible to receive a rebate generally covering 30% - 70% of the project cost. These retrofits improve light quality and reduce energy costs in participating facilities. PLC

95

Fixture for supporting and aligning a sample to be analyzed in an x-ray diffraction apparatus  

DOE Patents (OSTI)

A fixture is provided for supporting and aligning small samples of material on a goniometer for x-ray diffraction analysis. A sample-containing capillary is accurately positioned for rotation in the x-ray beam by selectively adjusting the fixture to position the capillary relative to the x and y axes thereof to prevent wobble and position the sample along the z axis or the axis of rotation. By employing the subject fixture relatively small samples of materials can be analyzed in an x-ray diffraction apparatus previously limited to the analysis of much larger samples.

Green, L.A.; Heck, J.L. Jr.

1985-04-23T23:59:59.000Z

96

Albany Water Gas & Light Comm | Open Energy Information  

Open Energy Info (EERE)

Water Gas & Light Comm Water Gas & Light Comm Jump to: navigation, search Name Albany Water Gas & Light Comm Place Georgia Utility Id 230 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Demand Commercial Commercial Non-Demand Commercial Large Commercial Demand Commercial Residential Residential Security Lights 1000 Watt Metal Halide Metal Pole Lighting Security Lights 1000 Watt Metal Halide Wooden Pole Lighting Security Lights 150 HPSV Fixtures Metal Pole Lighting Security Lights 150 HPSV Fixtures Wooden Pole Lighting

97

Light  

Science Journals Connector (OSTI)

Sunlight contains energy which can be directly converted into electricity in solar cells of various types. This is an example of what is called 'direct conversion', involving no moving parts or heat conversion processes. This chapter looks at photovoltaic and photoelectric devices and also at other ideas for using light energy, some of which operate in the infrared part of the spectrum. Solar electric power is a rapidly developing field, opening up many opportunities for novel applications, as well as requirements, including for storage, with one idea being solar-powered hydrogen production and then direct conversion to electricity in fuel cells. Direct conversion is not always efficient, and this chapter introduces the concept of 'energy return on energy invested'. In speculative mood this chapter also looks at the idea of a global grid, allowing daytime solar generation to be used on the night side of the planet.

David Elliott ? Pages 4-1 to 4-20

98

Calibrated vapor generator source  

DOE Patents (OSTI)

A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet. 10 figs.

Davies, J.P.; Larson, R.A.; Goodrich, L.D.; Hall, H.J.; Stoddard, B.D.; Davis, S.G.; Kaser, T.G.; Conrad, F.J.

1995-09-26T23:59:59.000Z

99

A hierarchical CSP search for path planning of cooperating self-reconfigurable mobile fixtures  

Science Journals Connector (OSTI)

Abstract The paper presents the application of artificial intelligence tools for the path planning of complex multi-agent robotic systems. In particular, a solution is proposed to the planning problem for the conjoint operation of two or more mobile robotic fixtures used for the manufacturing of large workpieces, like those used in the aerospace industry. Such fixturing systems have been recently designed and tested, raising hopes to better satisfy the dynamic conditions of modern manufacturing, with its increasing emphasis on flexibility, adaptability, and automation. The proposed planning method is novel in two fundamental aspects. First, it interprets planning as a constraint satisfaction problem (CSP), rather than as a constrained optimisation, an approach ubiquitous in the path and motion planning literature. Secondly, the formulated CSP is solved by a hierarchy of incremental state space search algorithms which differ in some way from the existing state of the art. This hierarchy includes levels related to the robot and workpiece arrangement parameters and to three components of mobile fixture agents: a supporting head, a mobile base, and a parallel manipulator, respectively. Due to the use of CSP search, the planner constitutes a largely application-independent framework, on the basis of which specific industrial implementations can be defined by supplying the relevant physical, geometrical, and time-related constraints.

W?odzimierz Kasprzak; Wojciech Szynkiewicz; Dimiter Zlatanov; Teresa Zieli?ska

2014-01-01T23:59:59.000Z

100

Lighting Retrofit Improving Visibility, Saving Energy | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting Retrofit Improving Visibility, Saving Energy Lighting Retrofit Improving Visibility, Saving Energy Lighting Retrofit Improving Visibility, Saving Energy August 27, 2010 - 10:05am Addthis New LED lighting fixtures (right) emit a whiter light than existing high-pressure sodium cobra head streetlights (left) and don't spill light onto nearby houses. | Photos courtesy of the City of Muscatine New LED lighting fixtures (right) emit a whiter light than existing high-pressure sodium cobra head streetlights (left) and don't spill light onto nearby houses. | Photos courtesy of the City of Muscatine Kevin Craft In the small Midwestern town of Muscatine, Iowa-known as the "The Pearl Button Capital of the World" for the millions of pearl buttons produced there in the early 1900s-a lighting retrofit project will bring a new

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

MidAmerican Energy (Electric) - Municipal Solid-State Lighting MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant Program MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant Program < Back Eligibility Local Government Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Minimum project size for the full $5,000 grant is 20 fixtures; smaller projects will receive a $250 per-fixture grant. Program Info State Iowa Program Type Utility Grant Program Rebate Amount Up to $5,000 Provider MidAmerican Energy Company MidAmerican Energy offers grants to munipalities which implement solid-state roadway street lighting upgrades. Grants of up to $5,000 are available to participating entities who install eligible roadway lighting fixtures. Participants must be an Iowa electric governmental customer of

102

Lighting Research Group: Facilities  

NLE Websites -- All DOE Office Websites (Extended Search)

Facilities Facilities Lighting Research Facilities at LBNL gonio-photometer Gonio-photometer We use this device to measure the intensity and direction of the light from a lamp or fixture. integrating sphere Integrating sphere This instrument allows us to get a fast and accurate measurement of the total light output of a lamp. We are not able to determine the direction of the light, only the intensity. power analyzer Power analyzer We use our power analyzer with the lamps in the gonio-photometer to measure input power, harmonic distortion, power factor, and many other signals that tell us how well a lamp is performing. spectro-radiometer Spectro-radiometer This device measures not only the intensity of a light source but also the intensity of the light at each wavelength.

103

How Do You Save on Lighting Costs? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

on Lighting Costs? on Lighting Costs? How Do You Save on Lighting Costs? May 6, 2010 - 7:30am Addthis This week, Amy discussed ENERGY STAR lighting fixtures and how they can help you save on lighting costs. Lighting accounts for roughly 11% of a typical residential utility bill, so it's worth seeking ways to reduce your energy use and costs. ENERGY STAR fixtures, efficient lighting choices, and turning off the lights can all help you save. How do you save on lighting costs? Each Thursday, you have the chance to share your thoughts on a question about energy efficiency or renewable energy for consumers. Please comment with your answers, and also feel free to respond to other comments. E-mail your responses to the Energy Saver team at consumer.webmaster@nrel.gov Addthis Related Articles

104

How Do You Save on Lighting Costs? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

How Do You Save on Lighting Costs? How Do You Save on Lighting Costs? How Do You Save on Lighting Costs? May 6, 2010 - 7:30am Addthis This week, Amy discussed ENERGY STAR lighting fixtures and how they can help you save on lighting costs. Lighting accounts for roughly 11% of a typical residential utility bill, so it's worth seeking ways to reduce your energy use and costs. ENERGY STAR fixtures, efficient lighting choices, and turning off the lights can all help you save. How do you save on lighting costs? Each Thursday, you have the chance to share your thoughts on a question about energy efficiency or renewable energy for consumers. Please comment with your answers, and also feel free to respond to other comments. E-mail your responses to the Energy Saver team at consumer.webmaster@nrel.gov

105

Information Resources: Solid-State Lighting Videos  

NLE Websites -- All DOE Office Websites (Extended Search)

Videos Videos On this page you can access DOE Solid-State Lighting (SSL) Program videos. Photo of a museum art gallery with LED lights in track fixtures overhead. The City of Los Angeles LED Streetlight Program View the video about the Los Angeles LED streetlight program, featuring an interview with City of Los Angeles Bureau of Street Lighting Director, Ed Ebrahimian. Photo of a museum art gallery with LED lights in track fixtures overhead. The Smithsonian American Art Museum GATEWAY Demonstration View the video about using LEDs in a GATEWAY demonstration at the Smithsonian American Art Museum in Washington, DC, including an interview with lighting designer Scott Rosenfeld. graphic of many intersecting white lines on a blue background Orchestrating Market Success

106

Optical monitor for water vapor concentration  

DOE Patents (OSTI)

A system for measuring and monitoring water vapor concentration in a sample uses as a light source an argon discharge lamp, which inherently emits light with a spectral line that is close to a water vapor absorption line. In a preferred embodiment, the argon line is split by a magnetic field parallel to the direction of light propagation from the lamp into sets of components of downshifted and upshifted frequencies of approximately 1575 Gauss. The downshifted components are centered on a water vapor absorption line and are thus readily absorbed by water vapor in the sample; the upshifted components are moved away from that absorption line and are minimally absorbed. A polarization modulator alternately selects the upshifted components or downshifted components and passes the selected components to the sample. After transmission through the sample, the transmitted intensity of a component of the argon line varies as a result of absorption by the water vapor. The system then determines the concentration of water vapor in the sample based on differences in the transmitted intensity between the two sets of components. In alternative embodiments alternate selection of sets of components is achieved by selectively reversing the polarity of the magnetic field or by selectively supplying the magnetic field to the emitting plasma. 5 figs.

Kebabian, P.

1998-06-02T23:59:59.000Z

107

Optical monitor for water vapor concentration  

DOE Patents (OSTI)

A system for measuring and monitoring water vapor concentration in a sample uses as a light source an argon discharge lamp, which inherently emits light with a spectral line that is close to a water vapor absorption line. In a preferred embodiment, the argon line is split by a magnetic field parallel to the direction of light propagation from the lamp into sets of components of downshifted and upshifted frequencies of approximately 1575 Gauss. The downshifted components are centered on a water vapor absorption line and are thus readily absorbed by water vapor in the sample; the upshifted components are moved away from that absorption line and are minimally absorbed. A polarization modulator alternately selects the upshifted components or downshifted components and passes the selected components to the sample. After transmission through the sample, the transmitted intensity of a component of the argon line varies as a result of absorption by the water vapor. The system then determines the concentration of water vapor in the sample based on differences in the transmitted intensity between the two sets of components. In alternative embodiments alternate selection of sets of components is achieved by selectively reversing the polarity of the magnetic field or by selectively supplying the magnetic field to the emitting plasma.

Kebabian, Paul (Acton, MA)

1998-01-01T23:59:59.000Z

108

The light-emitting diode (LED) is an fairly new kind of light source found currently in  

E-Print Network (OSTI)

this technology an ideal replacement for less efficient incandescent light sources, particularly in applications elevator lighting has the potential to achieve 25 percent greater efficiency than current incandescent ILLUMINATION LEVELS SIMILAR TO THOSE OF INCANDESCENT FIXTURES WHILE CUTTING ENERGY USE 45 PERCENT. ELEVATOR

109

Springfield Utility Board - Energy Smart Lighting Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Springfield Utility Board - Energy Smart Lighting Program Springfield Utility Board - Energy Smart Lighting Program Springfield Utility Board - Energy Smart Lighting Program < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit State Government Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Commercial Lighting Replacement: $1,500 Program Info State Oregon Program Type Utility Rebate Program Rebate Amount Incentives are based upon three programs offered by SUB: New Construction Lighting: $10 - $50/light fixture Commercial Lighting Replacement: $3 - $100 Commercial Lighting Implementation: not specified Energy Smart Design Office: $0.50 per square foot Provider Springfield Utility Board The Springfield Utility Board (SUB) works with their commercial customers

110

600 New Lights Bulbs to Improve Energy Efficiency at DOE | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

600 New Lights Bulbs to Improve Energy Efficiency at DOE 600 New Lights Bulbs to Improve Energy Efficiency at DOE 600 New Lights Bulbs to Improve Energy Efficiency at DOE November 18, 2010 - 10:30am Addthis Ingrid Kolb Director of the Office of Management Starting in September, the Department of Energy has been steadily replacing all 600 light fixtures under our Washington, D.C., Forrestal North Building canopy with state of the art Light Emitting Diode (LED) fixtures. Every new bulb now uses just 23 watts instead of 205 watts. That translates into almost half a million kilowatts hours saved every year. and will cut annual energy consumption at the Department of Energy Headquarters by about 1%. The final new LED fixture under the canopy was installed on October 28, but these lights are just part of a full program to reduce energy consumption

111

ARM Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

ARM Water Vapor IOP The SGP CART site will host the third ARM water vapor IOP on September 18-October 8, 2000. The CART site is home to a powerful array of instruments capable of...

112

CoServ Electric Cooperative - Commercial Energy Efficient Lighting Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CoServ Electric Cooperative - Commercial Energy Efficient Lighting CoServ Electric Cooperative - Commercial Energy Efficient Lighting Rebate Program CoServ Electric Cooperative - Commercial Energy Efficient Lighting Rebate Program < Back Eligibility Commercial Industrial Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info Funding Source Via partnership with whole sale provider Brazos Electric Power, Inc. and escheat funds Start Date 09/01/2009 State Texas Program Type Utility Rebate Program Rebate Amount Custom Lighting Upgrade: 0.30/watt saved per fixture T8 Fluorescent Upgrade: 1.50 - 2.25/bulb per fixture Provider CoServ Electric Cooperative CoServ Electric Cooperative provides rebates for commercial and industrial customers who upgrade to high efficiency lighting for the workplace. A rebate of $0.30/watt saved is available on custom lighting upgrades and a

113

New and Underutilized Technology: Efficient High Bay Fluorescent Lighting |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Efficient High Bay Fluorescent Efficient High Bay Fluorescent Lighting New and Underutilized Technology: Efficient High Bay Fluorescent Lighting October 7, 2013 - 8:54am Addthis The following information outlines key deployment considerations for efficient high bay fluorescent lighting within the Federal sector. Benefits Efficient high bay fluorescent lighting can include either T5 or T8 fluorescent lighting systems for high-bay applications currently using metal halide fixtures. Fluorescent fixtures offer better light distribution, better light maintenance over the life of the lamp, improved color quality, and on-off control (re-strike time) with lower energy consumption. Application Efficient high bay fluorescent lighting is applicable for facilities containing high bay areas. Key Factors for Deployment

114

Lighting Designer Roundtable on Solid-State Lighting  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

correctly to obtain luminaire input power. Third, ensure that losses from fixture optics such as lenses are included in fixture efficiency, or apply a separate loss factor for...

115

Agricultural Lighting and Equipment Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Agricultural Lighting and Equipment Rebate Program Agricultural Lighting and Equipment Rebate Program Agricultural Lighting and Equipment Rebate Program < Back Eligibility Agricultural Savings Category Other Appliances & Electronics Commercial Lighting Lighting Manufacturing Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Varies according to technology; prescriptive and custom rebates available Provider Efficiency Vermont In Vermont, agricultural operations are eligible for prescriptive and customized incentives on equipment proven to help make farms more efficient. Prescriptive rebates are available for lighting (free to $175 per fixture, depending on the type of fixture or lighting) and for a variety of equipment including plate coolers, variable speed milk transfer

116

Vapor spill monitoring method  

DOE Patents (OSTI)

Method for continuous sampling of liquified natural gas effluent from a spill pipe, vaporizing the cold liquified natural gas, and feeding the vaporized gas into an infrared detector to measure the gas composition. The apparatus utilizes a probe having an inner channel for receiving samples of liquified natural gas and a surrounding water jacket through which warm water is flowed to flash vaporize the liquified natural gas.

Bianchini, Gregory M. (Livermore, CA); McRae, Thomas G. (Livermore, CA)

1985-01-01T23:59:59.000Z

117

ARM - Water Vapor  

NLE Websites -- All DOE Office Websites (Extended Search)

Water Vapor Outreach Home Room News Publications Traditional Knowledge Kiosks Barrow, Alaska Tropical Western Pacific Site Tours Contacts Students Study Hall About ARM Global...

118

Wire fixturing in high wire-number z pinches critical for high radiation power and reproducibility  

SciTech Connect

The quality of high wire-number z-pinch implosions on Z using a dynamic hohlraum (DH) configuration [Sanford, et al., Phys. Plasmas 9, 3573 (2002)] is significantly affected by the method of holding the wires. The three arrangements discussed here have led to differences in radial and axial x-ray powers of factors of 1.6{+-}0.2 and 1.5{+-}0.2, respectively. An increase in power is accompanied by reductions in rise time and pulse width, and improvements in shot-to-shot reproducibility. Higher powers are produced by fixtures that enable the wires to be maintained taut, which also produce superior current contacts at the electrodes (and in particular at the cathode) prior to implosion. The increased axial power, and decreased variation in power and pulse shape, correlate with decreased wire-plasma material observed at the axial radiation exit holes of the DH.

Sanford, T.W.L.; Mock, R.C.; Seamen, J.F.; Lopez, M.R.; Watt, R.G.; Idzorek, G.C.; Peterson, D.L. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States); Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

2005-12-15T23:59:59.000Z

119

New Energy Efficiency Standards for Metal Halide Lamp Fixtures to Save on Energy Bills and Reduce Carbon Pollution  

Office of Energy Efficiency and Renewable Energy (EERE)

As part of the Energy Department’s efforts to develop efficiency standards that cut carbon pollution and save money by saving energy, U.S. Energy Secretary Ernest Moniz announced that the Department has finalized new energy efficiency standards for metal halide lamp fixtures.

120

High Hats, Swiss Cheese, and Fluorescent Lighting?  

SciTech Connect

For DOE, PNNL is conducting a competitive procurement to promote market introduction of new residential recessed downlights (also known as ''recessed cans'' or ''high hats'') that are airtight, rated for insulated ceilings, and hard-wired for CFLs. This paper discusses the potential energy savings of new high-efficiency downlights, and the results of product testing to date. Recessed downlights are the most popular residential lighting fixtures in the United States, with 21.7 million fixtures sold in 2000. An estimated 350 million are currently installed in American homes. Recessed cans are relatively inexpensive, and provide an unobtrusive, directed source of light for kitchens, hallways, and living rooms. Recessed cans are energy-intensive in three ways. First, virtually all recessed cans currently installed in the residential sector use incandescent light sources, typically reflector-type lamps drawing 65-150 watts. Second, heat from incandescent lamps adds to air-conditioning loads. Third, most installed recessed cans are not airtight, so they allow conditioned air to escape from the living area into unconditioned spaces such as attics. Addressing both lighting energy use and air leakage in recessed cans has proven challenging. Lighting energy efficiency is greatly improved by using CFLs. Air leakage can be addressed by making fixtures airtight. But when CFLs are used in an airtight recessed can, heat generated by the lamp and ballast is trapped within the fixture. Excessive heat causes reduced light output and shorter lifespan of the CFL. The procurement was designed to overcome these technical challenges and make new products available in the marketplace.

McCullough, Jeffrey J.; Gordon, Kelly L.

2002-08-30T23:59:59.000Z

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Total Light Management  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Light Management Light Management Why is saving Energy Important World Electricity Consumption (2007) Top 20 Countries 0 500 1000 1500 2000 2500 3000 3500 4000 4500 U n i t e d S t a t e s C h i n a J a p a n R u s s i a I n d i a G e r m a n y C a n a d a A f r i c a F r a n c e B r a z i l K o r e a , S o u t h U n i t e d K i n g d o m I t a l y S p a i n A u s t r a l i a T a i w a n S o u t h A f r i c a M e x i c o S a u d i A r a b i a I r a n Billion kWh Source: US DOE Energy Information Administration Lighting Control Strategies 4 5 6 Occupancy/Vacancy Sensing * The greatest energy savings achieved with any lighting fixture is when the lights are shut off * Minimize wasted light by providing occupancy sensing or vacancy sensing 7 8 Daylight Harvesting * Most commercial space has enough natural light flowing into it, and the amount of artificial light being generated can be unnecessary * Cut back on the production of artificial lighting by

122

Cheyenne Light, Fuel and Power (Electric) - Commercial Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electric) - Commercial Energy Electric) - Commercial Energy Efficiency Rebate Program (Wyoming) Cheyenne Light, Fuel and Power (Electric) - Commercial Energy Efficiency Rebate Program (Wyoming) < Back Eligibility Commercial Industrial Savings Category Other Appliances & Electronics Commercial Lighting Lighting Manufacturing Maximum Rebate Custom: 50% of project cost Program Info Start Date 06/09/2011 State Wyoming Program Type Utility Rebate Program Rebate Amount T8 Fixtures: $5 - $18 /system or $0.50 /lamp Fluorescents: $4 - $125 CFLs: $8 - $25 Indirect Lighting: $16 - $24 Pulse Start Metal Halide Fixtures: $25 - $65 Lighting Controls: $12 - $35 Variable Frequency Drive: $30 /hp Totally Enclosed Fan-Cooled: $10 - $600 Open Drip-Proof: $10 - $600 Custom: Buy down to 2 year pay back or 50% of cost, whichever is less

123

Richland Energy Services - Energy Efficient Commercial Lighting Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Richland Energy Services - Energy Efficient Commercial Lighting Richland Energy Services - Energy Efficient Commercial Lighting Program Richland Energy Services - Energy Efficient Commercial Lighting Program < Back Eligibility Agricultural Commercial Industrial Institutional Nonprofit Savings Category Other Appliances & Electronics Commercial Lighting Lighting Maximum Rebate 70% of the total cost Program Info Expiration Date 9/30/2012 State District of Columbia Program Type Utility Rebate Program Rebate Amount T5/T8 with Electric Ballasts: $10 - $65 Hardwired CFL's: $40 - $80 Screw In CFL's: $3 - $12 Cold Cathode: $3 - $15 Ceramic Metal Halide Fixture: $30 - $50 LED's: $15 - $50 Induction: $80 - $400 High-output T5/T8: $50 - $180 Metal Halide/High Pressure Sodium: $80 - $400 Stairwell/Garage Fluorescent Fixture: $50 Occupancy Sensor/Timer: $30 - $60

124

New River Light & Power Co | Open Energy Information  

Open Energy Info (EERE)

New River Light & Power Co New River Light & Power Co Place North Carolina Utility Id 13482 Utility Location Yes Ownership S NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt SV TOB Lighting 150 Watt SV TOB Lighting 150 Watt Sodium Vapor Lighting 175 Watt MV TOB Lighting 175 Watt Mercury Vapor Lighting 250 Watt Metal Halide Lighting 250 Watt SV TOB Lighting 250 Watt Sodium Vapor Lighting 400 Watt MV TOB Lighting 400 Watt Mercury Vapor Lighting 400 Watt Metal Halide Lighting 400 Watt SV TOB Lighting 750 Watt SV TOB Lighting

125

Demonstration Assessment of Light Emitting Diode (LED) Residential Downlights and Undercabinet Lights in the Lane County Tour of Homes, Eugene, Oregon  

SciTech Connect

In August 2008 the Pacific Northwest National Laboratory (PNNL) conducted a light emitting diode (LED) residential lighting demonstration project for the U.S. Department of Energy (DOE), Office of Building Technologies, as part of DOE’s Solid State Lighting (SSL) Technology Demonstration Gateway Program. Two lighting technologies, an LED replacement for downlight lamps (bulbs) and an LED undercabinet lighting fixture, were tested in the demonstration which was conducted in two homes built for the 2008 Tour of Homes in Eugene, Oregon. The homes were built by the Lane County Home Builders Association (HBA), and Future B Homes. The Energy Trust of Oregon (ETO) also participated in the demonstration project. The LED downlight product, the LR6, made by Cree LED Lighting Solutions acts as a screw-in replacement for incandescent and halogen bulbs in recessed can downlights. The second product tested is Phillips/Color Kinetics’ eW® Profile Powercore undercabinet fixture designed to mount under kitchen cabinets to illuminate the countertop and backsplash surfaces. Quantitative and qualitative measurements of light performance and electrical power usage were taken at each site before and after initially installed halogen and incandescent lamps were replaced with the LED products. Energy savings and simple paybacks were also calculated and builders who toured the homes were surveyed for their responses to the LED products. The LED downlight product drew 12 Watts of power, cutting energy use by 82% compared to the 65W incandescent lamp and by 84% compared to the 75W halogen lamp. The LED undercabinet fixture drew 10 watts, cutting energy use by 83% to 90% compared to the halogen product, which was tested at two power settings: a low power 60W setting and a high power 105W setting. The LED downlight consistently provided more light than the halogen and incandescent lamps in horizontal measurements at counter height and floor level. It also outperformed in vertical illuminance measurements taken on the walls, indicating better lateral dispersion of the light. The undercabinet fixture’s light output was midway between the low and high power halogen undercabinet fixture light outputs (35.8 foot candle versus 13.4 fc and 53.4 fc) but it produced a more uniform light (max/min ratio of 7.0 versus 10.8). The color correlated temperature (CCT, the blue or yellowness) of the LED light correlated well with the halogen and incandescent lights (2675 K vs 2700 K). The color rendering of the LED downlight also correlated well at 92 CRI compared to 100 CRI for the halogen and incandescent lamps. The LED undercabinet fixture had measures of 2880 K CCT and 71 CRI compared to the 2700 K and 100 CRI scores for the halogen undercabinet fixture. Builders who toured the homes were surveyed; they gave the LED downlight high marks for brightness, said the undercabinet improved shadows and glare and said both products improved overall visibility, home appearance, and home value. Paybacks on the LED downlight ranged from 7.6 years (assuming electricity cost of 11 c/kWh) to 13.5 years (at 5C/kWh). Paybacks on the LED undercabinet fixture in a new home ranged from 4.4 years (11c/kWh electricity) to 7.6 years (5c/kWh) based on product costs of $95 per LED downlight and $140 per LED undercabinet fixture at 3 hrs per day of usage for the downlight and 2 hrs per day for the undercabinet lighting.

Ton, My K.; Richman, Eric E.; Gilbride, Theresa L.

2008-11-10T23:59:59.000Z

126

Data:57766632-8930-4e58-bfd5-ff86403c7b43 | Open Energy Information  

Open Energy Info (EERE)

32-8930-4e58-bfd5-ff86403c7b43 32-8930-4e58-bfd5-ff86403c7b43 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Pendant Lamp Fixtures -Standard Ornamental Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

127

Data:C8a5447c-cf78-4549-9238-c7811d168f3d | Open Energy Information  

Open Energy Info (EERE)

47c-cf78-4549-9238-c7811d168f3d 47c-cf78-4549-9238-c7811d168f3d No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

128

Data:E37b36ec-074a-421d-9dcc-33030e5bf126 | Open Energy Information  

Open Energy Info (EERE)

6ec-074a-421d-9dcc-33030e5bf126 6ec-074a-421d-9dcc-33030e5bf126 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Mastarm Lamp Fixtures - Breakaway Base Standard Steel Pole Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

129

Data:D153e05a-9026-4559-814a-c5856890bfe6 | Open Energy Information  

Open Energy Info (EERE)

a-9026-4559-814a-c5856890bfe6 a-9026-4559-814a-c5856890bfe6 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures (Standard Steel/Concrete Pole) Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

130

Silescent Lighting Corp | Open Energy Information  

Open Energy Info (EERE)

Silescent Lighting Corp Silescent Lighting Corp Jump to: navigation, search Name Silescent Lighting Corp Place Fort Lauderdale, Florida Zip 33315 Product Florida-based LED lighting fixtures maker. References Silescent Lighting Corp[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Silescent Lighting Corp is a company located in Fort Lauderdale, Florida . References ↑ "Silescent Lighting Corp" Retrieved from "http://en.openei.org/w/index.php?title=Silescent_Lighting_Corp&oldid=351074" Categories: Clean Energy Organizations Companies Organizations Stubs What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load)

131

Gasoline vapor recovery  

SciTech Connect

In a gasoline distribution network wherein gasoline is drawn from a gasoline storage tank and pumped into individual vehicles and wherein the gasoline storage tank is refilled periodically from a gasoline tanker truck, a method of recovering liquid gasoline from gasoline vapor that collects in the headspace of the gasoline storage tank as the liquid gasoline is drawn therefrom, said method comprising the steps of: (a) providing a source of inert gas; (b) introducing inert gas into the gasoline storage tank as liquid gasoline is drawn therefrom so that liquid gasoline drawn from the tank is displaced by inert gas and gasoline vapor mixes with the inert gas in the headspace of the tank; (c) collecting the inert gas/gasoline vapor mixture from the headspace of the gasoline storage tank as the tank is refilled from a gasoline tanker truck; (d) cooling the inert gas/gasoline vapor mixture to a temperature sufficient to condense the gasoline vapor in the mixture to liquid gasoline but not sufficient to liquify the inert gas in the mixture; (e) separating the condensed liquid gasoline from the inert gas; and delivering the condensed liquid gasoline to a remote location for subsequent use.

Lievens, G.; Tiberi, T.P.

1993-06-22T23:59:59.000Z

132

Electrolyte vapor condenser  

DOE Patents (OSTI)

A system is disclosed for removing electrolyte from a fuel cell gas stream. The gas stream containing electrolyte vapor is supercooled utilizing conventional heat exchangers and the thus supercooled gas stream is passed over high surface area passive condensers. The condensed electrolyte is then drained from the condenser and the remainder of the gas stream passed on. The system is particularly useful for electrolytes such as phosphoric acid and molten carbonate, but can be used for other electrolyte cells and simple vapor separation as well. 3 figs.

Sederquist, R.A.; Szydlowski, D.F.; Sawyer, R.D.

1983-02-08T23:59:59.000Z

133

Electrolyte vapor condenser  

DOE Patents (OSTI)

A system is disclosed for removing electrolyte from a fuel cell gas stream. The gas stream containing electrolyte vapor is supercooled utilizing conventional heat exchangers and the thus supercooled gas stream is passed over high surface area passive condensers. The condensed electrolyte is then drained from the condenser and the remainder of the gas stream passed on. The system is particularly useful for electrolytes such as phosphoric acid and molten carbonate, but can be used for other electrolyte cells and simple vapor separation as well.

Sederquist, Richard A. (Newington, CT); Szydlowski, Donald F. (East Hartford, CT); Sawyer, Richard D. (Canton, CT)

1983-01-01T23:59:59.000Z

134

Recessed Lighting in the Limelight  

SciTech Connect

Recessed downlights are among the most popular installed lighting fixtures for new and remodeled homes. DOE estimates there are at least 350 million currently installed in US homes, and around 20 million are sold each year. A recent California study showed only 0.4 percent of recessed cans used compact fluorescent lamps. Annual reported sales of fluorescent residential recessed downlights nationwide make up no more than three percent of total residential recessed downlight sales. Standard recessed downlights waste energy by leaking conditioned air to unconditioned attic space, and using less efficient, high-heat incandescent bulbs. 33 states have adopted building codes that require recessed cans installed in the building shell to be airtight. To encourage lighting fixture manufacturers to bring to market high-efficiency air-tight recessed cans, DOE is sponsoring the recessed downlights project. PNNL solicited bids for energy efficient recessed downlights meeting the following specifications: They must use pin-based CFLs, have an airtight housing, be IC-rated, use electronic ballasts, and have a light output minimum of 900 initial lumens. PNNL did short- and long-term testing of the submitted lamps and negotiated lower prices for consumer purchase of qualifying models.

Gordon, Kelly L.; McCullough, Jeffrey J.

2003-02-01T23:59:59.000Z

135

Organic vapor jet printing system  

SciTech Connect

An organic vapor jet printing system includes a pump for increasing the pressure of an organic flux.

Forrest, Stephen R

2012-10-23T23:59:59.000Z

136

Industry Leaders, Research Experts Gather for Fourth Annual DOE Solid-State Lighting Workshop  

Energy.gov (U.S. Department of Energy (DOE))

More than 250 attendees gathered in Phoenix, Arizona, to participate in the 2007 DOE Solid-State Lighting (SSL) Program Planning Workshop on January 31-February 2, 2007. Lighting industry leaders, fixture manufacturers, researchers, academia, trade associations, lighting designers, energy efficiency organizations, and utilities joined DOE to share perspectives on the rapidly evolving SSL market. The workshop provided a forum for building partnerships and strategies to accelerate technology advances and guide market introduction of high efficiency, high-performance SSL products.

137

Mercury Vapor | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor Mercury Vapor Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Mercury Vapor Details Activities (23) Areas (23) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Lab Analysis Techniques Exploration Sub Group: Fluid Lab Analysis Parent Exploration Technique: Fluid Lab Analysis Information Provided by Technique Lithology: Stratigraphic/Structural: Anomalously high concentrations can indicate high permeability or conduit for fluid flow Hydrological: Field wide soil sampling can generate a geometrical approximation of fluid circulation Thermal: High concentration in soils can be indicative of active hydrothermal activity Dictionary.png Mercury Vapor: Mercury is discharged as a highly volatile vapor during hydrothermal

138

The USDOE Forrestal Building Lighting Retrofit: Preliminary Analysis of Electricity Savings  

E-Print Network (OSTI)

In September of 1993 a 36,832 fixture lighting retrofit was completed at the United States Department of Energy Forrestal complex in Washington, D.C. This retrofit represents DOE's largest project to date that utilizes a Shared Energy Savings (SES...

Haberl, J. S.; Bou-Saada, T. E.; Vajda, E. J.; Shincovich, M.; D'Angelo III, L.; Harris, L.

1994-01-01T23:59:59.000Z

139

Stratified vapor generator  

DOE Patents (OSTI)

A stratified vapor generator (110) comprises a first heating section (H.sub.1) and a second heating section (H.sub.2). The first and second heating sections (H.sub.1, H.sub.2) are arranged so that the inlet of the second heating section (H.sub.2) is operatively associated with the outlet of the first heating section (H.sub.1). A moisture separator (126) having a vapor outlet (164) and a liquid outlet (144) is operatively associated with the outlet (124) of the second heating section (H.sub.2). A cooling section (C.sub.1) is operatively associated with the liquid outlet (144) of the moisture separator (126) and includes an outlet that is operatively associated with the inlet of the second heating section (H.sub.2).

Bharathan, Desikan (Lakewood, CO); Hassani, Vahab (Golden, CO)

2008-05-20T23:59:59.000Z

140

Enrichment of light hydrocarbon mixture  

DOE Patents (OSTI)

Light hydrocarbon enrichment is accomplished using a vertically oriented distillation column having a plurality of vertically oriented, nonselective micro/mesoporous hollow fibers. Vapor having, for example, both propylene and propane is sent upward through the distillation column in between the hollow fibers. Vapor exits neat the top of the column and is condensed to form a liquid phase that is directed back downward through the lumen of the hollow fibers. As vapor continues to ascend and liquid continues to countercurrently descend, the liquid at the bottom of the column becomes enriched in a higher boiling point, light hydrocarbon (propane, for example) and the vapor at the top becomes enriched in a lower boiling point light hydrocarbon (propylene, for example). The hollow fiber becomes wetted with liquid during the process.

Yang, Dali (Los Alamos, NM); Devlin, David (Santa Fe, NM); Barbero, Robert S. (Santa Cruz, NM); Carrera, Martin E. (Naperville, IL); Colling, Craig W. (Warrenville, IL)

2011-11-29T23:59:59.000Z

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

WhiteOptics' Low-Cost Reflector Composite Boosts LED Fixture Efficiency  

Energy.gov (U.S. Department of Energy (DOE))

With the help of DOE funding, WhiteOptics has developed a composite coating that can be used to improve efficiency in backlit, indirect, and cavity-mixing LED luminaire designs by maximizing light reflection and output. The highly diffuse coating, which is based on a novel high-reflectance particle technology, allows for uniform distribution of light without exaggerating the point-source nature of the LEDs, and is intended to offer an overall system cost-improving solution for LED optics.

142

Evaluation of Waste Heat Recovery and Utilization from Residential Appliances and Fixtures  

SciTech Connect

Executive Summary In every home irrespective of its size, location, age, or efficiency, heat in the form of drainwater or dryer exhaust is wasted. Although from a waste stream, this energy has the potential for being captured, possibly stored, and then reused for preheating hot water or air thereby saving operating costs to the homeowner. In applications such as a shower and possibly a dryer, waste heat is produced at the same time as energy is used, so that a heat exchanger to capture the waste energy and return it to the supply is all that is needed. In other applications such as capturing the energy in drainwater from a tub, dishwasher, or washing machine, the availability of waste heat might not coincide with an immediate use for energy, and consequently a heat exchanger system with heat storage capacity (i.e. a regenerator) would be necessary. This study describes a two-house experimental evaluation of a system designed to capture waste heat from the shower, dishwasher clothes washer and dryer, and to use this waste heat to offset some of the hot water energy needs of the house. Although each house was unoccupied, they were fitted with equipment that would completely simulate the heat loads and behavior of human occupants including operating the appliances and fixtures on a demand schedule identical to Building American protocol (Hendron, 2009). The heat recovery system combined (1) a gravity-film heat exchanger (GFX) installed in a vertical section of drainline, (2) a heat exchanger for capturing dryer exhaust heat, (3) a preheat tank for storing the captured heat, and (4) a small recirculation pump and controls, so that the system could be operated anytime that waste heat from the shower, dishwasher, clothes washer and dryer, and in any combination was produced. The study found capturing energy from the dishwasher and clothes washer to be a challenge since those two appliances dump waste water over a short time interval. Controls based on the status of the dump valve on these two appliances would have eliminated uncertainty in knowing when waste water was flowing and the recovery system operated. The study also suggested that capture of dryer exhaust heat to heat incoming air to the dryer should be examined as an alternative to using drying exhaust energy for water heating. The study found that over a 6-week test period, the system in each house was able to recover on average approximately 3000 W-h of waste heat daily from these appliance and showers with slightly less on simulated weekdays and slightly more on simulated weekends which were heavy wash/dry days. Most of these energy savings were due to the shower/GFX operation, and the least savings were for the dishwasher/GFX operation. Overall, the value of the 3000 W-h of displaced energy would have been $0.27/day based on an electricity price of $.09/kWh. Although small for today s convention house, these savings are significant for a home designed to approach maximum affordable efficiency where daily operating costs for the whole house are less than a dollar per day. In 2010 the actual measured cost of energy in one of the simulated occupancy houses which waste heat recovery testing was undertaken was $0.77/day.

Tomlinson, John J [ORNL; Christian, Jeff [Oak Ridge National Laboratory (ORNL); Gehl, Anthony C [ORNL

2012-09-01T23:59:59.000Z

143

Vapor Barriers or Vapor Diffusion Retarders | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Home Air Sealing for New Home Construction Insulation Types of Insulation Insulation and Air Sealing Products and Services External Resources Find a Local AirVapor Barrier...

144

Laser vaporization/ionization interface for coupling microscale separation techniques with mass spectrometry  

DOE Patents (OSTI)

The present invention provides a laser-induced vaporization and ionization interface for directly coupling microscale separation processes to a mass spectrometer. Vaporization and ionization of the separated analytes are facilitated by the addition of a light-absorbing component to the separation buffer or solvent. 8 figs.

Yeung, E.S.; Chang, Y.C.

1999-06-29T23:59:59.000Z

145

New and Underutilized Technology: Bi-level Stairwell Lighting | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Stairwell Lighting Stairwell Lighting New and Underutilized Technology: Bi-level Stairwell Lighting October 7, 2013 - 8:53am Addthis The following information outlines key deployment considerations for bi-level stairwell lighting within the Federal sector. Benefits Bi-level stairwell lighting uses integral occupancy sensor motion detectors to monitor the stairwell. When occupancy is detected, the lights go to full level. When the space has been vacated after a programmed period, the fixture goes to a minimum level. Application Bi-level stairwell lighting is applicable in most multi-story buildings. Key Factors for Deployment Bi-level stairwell lighting is a good technology to implement concurrently with an overall building lighting improvement project. Ranking Criteria Federal energy savings, cost-effectiveness, and probability of success are

146

NYSEG (Electric) - Small Business Lighting Retrofit Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NYSEG (Electric) - Small Business Lighting Retrofit Program NYSEG (Electric) - Small Business Lighting Retrofit Program NYSEG (Electric) - Small Business Lighting Retrofit Program < Back Eligibility Commercial Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info Funding Source System Benefits Charge State New York Program Type Utility Rebate Program Rebate Amount Energy Assessment: Free Lighting Retrofit: 70% of cost Provider RG&E and NYSEG NYSEG offers a lighting incentive program designed to serve small business customers with a demand of 100 kilowatts (kW) or less. These small business customers may schedule a free energy assessment and then receive a 70% discount on the installed cost of recommended lighting measures. Eligible lighting measures include the retrofitting of fluorescent fixtures,

147

Data:9ed8f281-7c9a-4f4f-a8f0-1fabf477296b | Open Energy Information  

Open Energy Info (EERE)

-7c9a-4f4f-a8f0-1fabf477296b -7c9a-4f4f-a8f0-1fabf477296b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-250 W SV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

148

Data:506e7491-7a10-4e8b-bf1b-8e28fdee71d1 | Open Energy Information  

Open Energy Info (EERE)

91-7a10-4e8b-bf1b-8e28fdee71d1 91-7a10-4e8b-bf1b-8e28fdee71d1 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-175 W MV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

149

Storing images in warm atomic vapor  

E-Print Network (OSTI)

Reversible and coherent storage of light in atomic medium is a key-stone of future quantum information applications. In this work, arbitrary two-dimensional images are slowed and stored in warm atomic vapor for up to 30 $\\mu$s, utilizing electromagnetically induced transparency. Both the intensity and the phase patterns of the optical field are maintained. The main limitation on the storage resolution and duration is found to be the diffusion of atoms. A techniqueanalogous to phase-shift lithography is employed to diminish the effect of diffusion on the visibility of the reconstructed image.

M. Shuker; O. Firstenberg; R. Pugatch; A. Ron; N. Davidson

2008-06-17T23:59:59.000Z

150

Vapor spill pipe monitor  

DOE Patents (OSTI)

The invention is a method and apparatus for continually monitoring the composition of liquefied natural gas flowing from a spill pipe during a spill test by continually removing a sample of the LNG by means of a probe, gasifying the LNG in the probe, and sending the vaporized LNG to a remote ir gas detector for analysis. The probe comprises three spaced concentric tubes surrounded by a water jacket which communicates with a flow channel defined between the inner and middle, and middle and outer tubes. The inner tube is connected to a pump for providing suction, and the probe is positioned in the LNG flow below the spill pipe with the tip oriented partly downward so that LNG is continuously drawn into the inner tube through a small orifice. The probe is made of a high thermal conductivity metal. Hot water is flowed through the water jacket and through the flow channel between the three tubes to provide the necessary heat transfer to flash vaporize the LNG passing through the inner channel of the probe. The gasified LNG is transported through a connected hose or tubing extending from the probe to a remote ir sensor which measures the gas composition.

Bianchini, G.M.; McRae, T.G.

1983-06-23T23:59:59.000Z

151

E-Print Network 3.0 - atomic vapor density Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

T is temperature, Qris... F, is magnetic force, J is vapor plasma current density, c is speed of light, and B is magnetic flux... density. The induced magnetic force will act as...

152

Self-tuning method for monitoring the density of a gas vapor component using a tunable laser  

DOE Patents (OSTI)

The present invention relates to a vapor density monitor and laser atomic absorption spectroscopy method for highly accurate, continuous monitoring of vapor densities, composition, flow velocity, internal and kinetic temperatures and constituent distributions. The vapor density monitor employs a diode laser, preferably of an external cavity design. By using a diode laser, the vapor density monitor is significantly less expensive and more reliable than prior art vapor density monitoring devices. In addition, the compact size of diode lasers enables the vapor density monitor to be portable. According to the method of the present invention, the density of a component of a gas vapor is calculated by tuning the diode laser to a frequency at which the amount of light absorbed by the component is at a minimum or a maximum within about 50 MHz of that frequency. Laser light from the diode laser is then transmitted at the determined frequency across a predetermined pathlength of the gas vapor. By comparing the amount of light transmitted by the diode laser to the amount of light transmitted after the laser light passes through the gas vapor, the density of the component can be determined using Beer's law.

Hagans, Karla (Livermore, CA); Berzins, Leon (Livermore, CA); Galkowski, Joseph (Livermore, CA); Seng, Rita (Tracy, CA)

1996-01-01T23:59:59.000Z

153

Self-tuning method for monitoring the density of a gas vapor component using a tunable laser  

DOE Patents (OSTI)

The present invention relates to a vapor density monitor and laser atomic absorption spectroscopy method for highly accurate, continuous monitoring of vapor densities, composition, flow velocity, internal and kinetic temperatures and constituent distributions. The vapor density monitor employs a diode laser, preferably of an external cavity design. By using a diode laser, the vapor density monitor is significantly less expensive and more reliable than prior art vapor density monitoring devices. In addition, the compact size of diode lasers enables the vapor density monitor to be portable. According to the method of the present invention, the density of a component of a gas vapor is calculated by tuning the diode laser to a frequency at which the amount of light absorbed by the component is at a minimum or a maximum within about 50 MHz of that frequency. Laser light from the diode laser is then transmitted at the determined frequency across a predetermined pathlength of the gas vapor. By comparing the amount of light transmitted by the diode laser to the amount of light transmitted after the laser light passes through the gas vapor, the density of the component can be determined using Beer`s law. 6 figs.

Hagans, K.; Berzins, L.; Galkowski, J.; Seng, R.

1996-08-27T23:59:59.000Z

154

Lansing Board of Water and Light - Hometown Energy Savers® Residential  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savers® Savers® Residential Rebates Lansing Board of Water and Light - Hometown Energy Savers® Residential Rebates < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Appliances & Electronics Construction Heating Heat Pumps Commercial Lighting Lighting Water Heating Other Program Info State Michigan Program Type Utility Rebate Program Rebate Amount Small Business Direct Install Program: No cost or purchase necessary for participation Custom $0.08/kWh Commercial Cooking Equipment: Varies Commercial Refrigeration Equipment: Varies Lighting Compact Fluorescent Lamps: $1.50-$8 Compact Fluorescent Lamp Fixtures: $20 LED Lamps: $5-$15 LED Fixtures: $20 LED Exit Signs: $12.50

155

Thermal Issues Associated with the Lighting Systems, Electronics Racks, and Pre-Amplifier Modules in the National Ignition System  

SciTech Connect

This report summarizes an investigation of the thermal issues related to the National Ignition Facility. The influence of heat sources such as lighting fixtures, electronics racks, and pre-amplifier modules (PAMs) on the operational performance of the laser guide beam tubes and optical alignment hardware in the NE laser bays were investigated with experiments and numerical models. In particular, empirical heat transfer data was used to establish representative and meaningful boundary conditions and also serve as bench marks for computational fluid dynamics (CFD) models. Numerical models, constructed with a commercial CFD code, were developed to investigate the extent of thermal plumes and radiation heat transfer from the heat sources. From these studies, several design modifications were recommended including reducing the size of all fluorescent lights in the NIF laser bays to single 32 W bulb fixtures, maintaining minimum separation distances between light fixtures/electronics racks and beam transport hardware, adding motion sensors in areas of the laser bay to control light fixture operation during maintenance procedures, properly cooling all electronics racks with air-water heat exchangers with heat losses greater than 25 W/rack to the M1 laser bay, ensuring that the electronics racks are not overcooked and thus maintain their surface temperatures to within a few degrees centigrade of the mean air temperature, and insulating the electronic bays and optical support structures on the PAMs.

A. C. Owen; J. D. Bernardin; K. L. Lam

1998-08-01T23:59:59.000Z

156

Hydrogen Cars and Water Vapor  

E-Print Network (OSTI)

. This cycle is currently under way with hydrogen fuel cells. As fuel cell cars are suggested as a solutionHydrogen Cars and Water Vapor D.W.KEITHANDA.E.FARRELL'S POLICY FORUM "Rethinking hydrogen cars" (18 misidentified as "zero-emissions vehicles." Fuel cell vehicles emit water vapor. A global fleet could have

Colorado at Boulder, University of

157

Fuel vapor control device  

SciTech Connect

A fuel vapor control device is described having a valve opening and closing a passage connecting a carburetor and a charcoal canister according to a predetermined temperature. A first coil spring formed by a ''shape memory effect'' alloy is provided to urge the valve to open the passage when the temperature is high. A second coil spring urges the valve to close the passage. A solenoid is provided to urge an armature against the valve to close the passage against the force of the first coil spring when the engine is running. The solenoid heats the first coil spring to generate a spring force therein when the engine is running. When the engine is turned off, the solenoid is deactivated, and the force of the first spring overcomes the force of the second spring to open the passage until such time as the temperature of the first spring drops below the predetermined temperature.

Ota, I.; Nishimura, Y.; Nishio, S.; Yogo, K.

1987-10-20T23:59:59.000Z

158

The Dust Settles on Water Vapor Feedback  

Science Journals Connector (OSTI)

...To understand water vapor feedback...shifts in the atmospheric circulation...caused a positive water vapor feedback...temperature. Condensation, evaporation...shifts in the atmospheric circulation...caused a positive water vapor feedback...temperature. Condensation, evaporation...

Anthony D. Del Genio

2002-04-26T23:59:59.000Z

159

Category:Mercury Vapor | Open Energy Information  

Open Energy Info (EERE)

search GEOTHERMAL ENERGYGeothermal Home Geothermalpower.jpg Looking for the Mercury Vapor page? For detailed information on Mercury Vapor as exploration techniques,...

160

Hospital remedies architect's lighting overdesign for $22k: installs current limiters  

SciTech Connect

St. Luke's Hospital in Racine, Wisconsin is spending $22,000 to install current limiters in the fluorescent lamps of a new wing after finding that the architectural firm overdesigned the lighting fixtures so much that the hospital's lighting expenses were 50% higher than necessary. The hospital expects an 8-month payback on the current limiters. The hospital's corridor lighting reached 45-55 footcandles (fc), when only three fc are required for emergency lighting and 15 for corridor lighting. Representatives of the architectural firm argued that the design did not exceed state wattage requirements.

Ponczak, G.

1984-10-29T23:59:59.000Z

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Seattle City Light - New Construction Incentive Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Seattle City Light - New Construction Incentive Program Seattle City Light - New Construction Incentive Program Seattle City Light - New Construction Incentive Program < Back Eligibility Commercial Industrial Savings Category Other Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount Energy Analysis Assistance: Contact Seattle City Light Commissioning Assistance: Contact Seattle City Light Prescriptive Commercial Rebates Lighting: $0.02 - $0.23/kWh saved or $3 - $86/fixture Lighting Controls: $0.20 - $0.26/kWh saved or $30 - $90/sensor HVAC Controls: $0.20 - $0.23 Chillers: $0.23-$0.34 per kWh saved Air Conditioners: $0.20 -$0.23 per kWh saved Heat Pumps $0.20-$0.27 per kWh saved Economizers: $0.20 - $0.23 Cooling Towers: $0.23 - $0.27 Server Virtualization: $150 per server removed

162

Seattle City Light - Commercial Energy Efficiency Rebate Programs |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Seattle City Light - Commercial Energy Efficiency Rebate Programs Seattle City Light - Commercial Energy Efficiency Rebate Programs Seattle City Light - Commercial Energy Efficiency Rebate Programs < Back Eligibility Commercial Industrial Institutional Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Other Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate 70% of cost Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount Lighting: $0.02 - $0.23/kWh saved or $3 - $86/fixture Lighting Controls: $0.20 - $0.26/kWh saved or $30 - $90/sensor HVAC Controls: $0.20 - $0.23 Chillers: $0.23-$0.34 per kWh saved Air Conditioners: $0.20 -$0.23 per kWh saved Heat Pumps $0.20-$0.27 per kWh saved

163

Central Hudson Gas and Electric (Electric) - Commercial Lighting Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Lighting Commercial Lighting Rebate Program Central Hudson Gas and Electric (Electric) - Commercial Lighting Rebate Program < Back Eligibility Commercial Installer/Contractor Institutional Local Government Nonprofit Schools Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info State New York Program Type Utility Rebate Program Rebate Amount Up to 70% of the equipment cost of a qualified efficiency upgrade Provider Central Hudson Gas and Electric Central Hudson Gas and Electric's (Central Hudson) Commercial Lighting Rebate Program is for businesses, retailers, institutional customers and non-profit customers of Central Hudson. The progam utilizes the services of Lime Energy to install new lighting fixtures with Central Hudson covering up to 70% of the cost. The 30 percent of cost remaining can be financed at

164

Detroit Public Lighting Department - Commercial and Industrial Energy Wise  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Detroit Public Lighting Department - Commercial and Industrial Detroit Public Lighting Department - Commercial and Industrial Energy Wise Program Detroit Public Lighting Department - Commercial and Industrial Energy Wise Program < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Cooling Other Sealing Your Home Design & Remodeling Windows, Doors, & Skylights Manufacturing Heat Pumps Appliances & Electronics Commercial Lighting Lighting Insulation Maximum Rebate $50,000 per customer/facility, or 100% of the project cost Program Info State Michigan Program Type Utility Rebate Program Rebate Amount Light Fixtures: $2-$200 Lighting Controls: $0.10-$65 HVAC Equipment: $10-$30/ton Programmable Thermostat: $80 Window Glazing: $0.30/square foot

165

Types of Lighting in Commercial Buildings - Lighting Types  

U.S. Energy Information Administration (EIA) Indexed Site

Lighting Types Lighting Types The following are the most widely used types of lighting equipment used in commercial buildings. Characteristics such as energy efficiency, light quality, and lifetime vary by lamp type. Standard Fluorescent A fluorescent lamp consists of a sealed gas-filled tube. The gas in the tube consists of a mixture of low pressure mercury vapor and an inert gas such as argon. The inner surface of the tube has a coating of phosphor powder. When an electrical current is applied to electrodes in the tube, the mercury vapor emits ultraviolet radiation which then causes the phosphor coating to emit visible light (the process is termed fluorescence). A ballast is required to regulate and control the current and voltage. Two types of ballasts are used, magnetic and electronic. Electronic ballasts

166

Vapor deposition of hardened niobium  

DOE Patents (OSTI)

A method of coating ceramic nuclear fuel particles containing a major amount of an actinide ceramic in which the particles are placed in a fluidized bed maintained at ca. 800.degree. to ca. 900.degree. C., and niobium pentachloride vapor and carbon tetrachloride vapor are led into the bed, whereby niobium metal is deposited on the particles and carbon is deposited interstitially within the niobium. Coating apparatus used in the method is also disclosed.

Blocher, Jr., John M. (Columbus, OH); Veigel, Neil D. (Columbus, OH); Landrigan, Richard B. (Columbus, OH)

1983-04-19T23:59:59.000Z

167

Chemical vapor deposition sciences  

SciTech Connect

Chemical vapor deposition (CVD) is a widely used method for depositing thin films of a variety of materials. Applications of CVD range from the fabrication of microelectronic devices to the deposition of protective coatings. New CVD processes are increasingly complex, with stringent requirements that make it more difficult to commercialize them in a timely fashion. However, a clear understanding of the fundamental science underlying a CVD process, as expressed through computer models, can substantially shorten the time required for reactor and process development. Research scientists at Sandia use a wide range of experimental and theoretical techniques for investigating the science of CVD. Experimental tools include optical probes for gas-phase and surface processes, a range of surface analytic techniques, molecular beam methods for gas/surface kinetics, flow visualization techniques and state-of-the-art crystal growth reactors. The theoretical strategy uses a structured approach to describe the coupled gas-phase and gas-surface chemistry, fluid dynamics, heat and mass transfer of a CVD process. The software used to describe chemical reaction mechanisms is easily adapted to codes that model a variety of reactor geometries. Carefully chosen experiments provide critical information on the chemical species, gas temperatures and flows that are necessary for model development and validation. This brochure provides basic information on Sandia`s capabilities in the physical and chemical sciences of CVD and related materials processing technologies. It contains a brief description of the major scientific and technical capabilities of the CVD staff and facilities, and a brief discussion of the approach that the staff uses to advance the scientific understanding of CVD processes.

NONE

1992-12-31T23:59:59.000Z

168

Westinghouse and Fuzhou Permitted to Restart Distribution of Light Bulb  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Westinghouse and Fuzhou Permitted to Restart Distribution of Light Westinghouse and Fuzhou Permitted to Restart Distribution of Light Bulb Products Westinghouse and Fuzhou Permitted to Restart Distribution of Light Bulb Products August 6, 2010 - 4:26pm Addthis The Department has issued Notices of Allowance to Westinghouse Lighting Corporation and Fuzhou Sunlight Lighting Electrical Appliance Company determining, based on corrected test data provided by Westinghouse, that the incandescent reflector lamps listed below are compliant with the federal energy conservation standard and may be sold in the United States. These 11 Westinghouse brand lamps, usually used in recessed light fixtures, correspond to 7 basic models, which are manufactured in China by Fuzhou. DOE had previously issued Notices requiring Fuzhou and Westinghouse to

169

LED Lighting on the National Mall | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

LED Lighting on the National Mall LED Lighting on the National Mall LED Lighting on the National Mall Addthis 1 of 8 Facing East toward the Capitol Building, LED retrofitted lights line the interior paths of the mall while preserving the architectural integrity of the original fixtures. Image: Energy Department Image | Photo by Quentin Kruger (Contractor) | Public Domain Date taken: 2012-01-30 06:00 2 of 8 Energy Secretary Steven Chu discusses the 65% savings on electric bills and lowered maintenance costs the National Parks Service is experiencing by switching to energy efficient LED lights. "Using energy-efficient LED light bulbs is an important way Americans can save money by saving energy," said Secretary Chu. "Investing in an American economy that is built to last includes taking advantage of all of America's energy resources while

170

ComEd - Business Instant Lighting Discounts Program (Illinois) | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ComEd - Business Instant Lighting Discounts Program (Illinois) ComEd - Business Instant Lighting Discounts Program (Illinois) ComEd - Business Instant Lighting Discounts Program (Illinois) < Back Eligibility Commercial Industrial Multi-Family Residential Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info Funding Source Illinois Energy Efficiency Portfolio Standard (EEPS) surcharge Start Date 06/01/2012 State Illinois Program Type Utility Rebate Program Rebate Amount Varies by technology ComEd offers the Business Instant Lighting Discounts program to businesses, multi-family properties and private schools. Incentives are available on a variety of reduced wattage lamps which can be installed as a direct replacement for standard lamps without having to rewire the fixture. Eligible lamps include screw-in CFLs, reduced wattage T8 and T5 linear

171

Lighting Controls : Daylighting The New York Times Building  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting Controls Lighting Controls Overview The architectural approach The owner's approach Daylighting field study Daylighting control systems Automated roller shades Procurement specifications Shades and Shade Controls Lighting Controls Visualizing daylight Commissioning/ verification Demand response Mainstream solutions Post-occupancy evaluation Publications Sponsors Project team Lighting Controls The lighting controls scope of work is based upon the philosophy that occupants of commercial office buildings prefer natural light to electric light. The lighting controls system specified by the Times Company for its new headquarters building is a DALI (Digital Addressable Lighting Interface) based system with dimmable fixtures throughout the interior space. This allows the system to dim down the electric lighting in response to daylight admittance. It also provides for variable target set points for illuminance levels at the work plane. The Times Company intends to establish and adjust target set points on a departmental basis. The lighting control sequences are described within the specification 16575. These sequences utilize occupancy sensors, photo sensors, switches and a time clock to control the lighting in the interior space on each floor. The emergency lighting system is also described within the specification. The lighting control sequences are tied to Control Intent Diagrams that divide up the space on each floor into its various control zones. The overall intent is to provide electric light only when the space is occupied and to provide as little electric light as is necessary to achieve the target set point for the work plane in a given department. A department usually occupies multiple floors.

172

The Vaporization Enthalpies and Vapor Pressures of Some Primary Amines of Pharmaceutical Importance by Correlation Gas  

E-Print Network (OSTI)

by Correlation Gas Chromatography Chase Gobble, Nigam Rath, and James Chickos* Department of Chemistry Information ABSTRACT: Vapor pressures, vaporization, and sublimation enthalpies of several pharmaceuticals and boiling temperatures when available. Sublimation enthalpies and vapor pressures are also evaluated for 1

Chickos, James S.

173

Three Notch Elec Member Corp | Open Energy Information  

Open Energy Info (EERE)

Notch Elec Member Corp Notch Elec Member Corp Jump to: navigation, search Name Three Notch Elec Member Corp Place Georgia Utility Id 18499 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 1000W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',Wood Pole (1)) Lighting 1000W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',Wood Pole (2)) Lighting 1000W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',FiberglassPole(3)) Lighting 1000W Underground Wiring (Non Mercury vapor fixtures) - (Type -

174

Kinetics of wet sodium vapor complex plasma  

SciTech Connect

In this paper, we have investigated the kinetics of wet (partially condensed) Sodium vapor, which comprises of electrons, ions, neutral atoms, and Sodium droplets (i) in thermal equilibrium and (ii) when irradiated by light. The formulation includes the balance of charge over the droplets, number balance of the plasma constituents, and energy balance of the electrons. In order to evaluate the droplet charge, a phenomenon for de-charging of the droplets, viz., evaporation of positive Sodium ions from the surface has been considered in addition to electron emission and electron/ion accretion. The analysis has been utilized to evaluate the steady state parameters of such complex plasmas (i) in thermal equilibrium and (ii) when irradiated; the results have been graphically illustrated. As a significant outcome irradiated, Sodium droplets are seen to acquire large positive potential, with consequent enhancement in the electron density.

Mishra, S. K., E-mail: nishfeb@rediffmail.com [Institute for Plasma Research (IPR), Gandhinagar 382428 (India); Sodha, M. S. [Centre of Energy Studies, Indian Institute of Technology Delhi (IITD), New Delhi 110016 (India)] [Centre of Energy Studies, Indian Institute of Technology Delhi (IITD), New Delhi 110016 (India)

2014-04-15T23:59:59.000Z

175

VAPORIZATION THERMODYNAMICS OF KCl. COMBINING VAPOR PRESSURE AND GRAVIMETRIC DATA  

E-Print Network (OSTI)

.B. Department of Chemistry, Moscow State University, Moscow, 119899, Russia Bonnell D.W., Hastie J.W. National temperature chemistry situations, vapor pressures are typically less than 100 kPa. The molar volume is p = 101325 Pa). The subscript trs denotes that the changeisfor a transition, typically sublimation

Rudnyi, Evgenii B.

176

RG&E (Electric) - Small Business Lighting Retrofit Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Small Business Lighting Retrofit Program Small Business Lighting Retrofit Program RG&E (Electric) - Small Business Lighting Retrofit Program < Back Eligibility Commercial Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info Funding Source System Benefits Charge State New York Program Type Utility Rebate Program Rebate Amount Energy Assessment: Free Lighting Retrofit: 70% of cost Provider RG&E and NYSEG RG&E offers a lighting incentive program designed to serve small business customers with a demand of 100 kilowatts (kW) or less. These small business customers may schedule a free energy assessment and then receive a 70% discount on the installed cost of recommended lighting measures. Eligible lighting measures include the retrofitting of fluorescent fixtures,

177

New and Underutilized Technology: Low Ambient/Task Lighting | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Low Ambient/Task Lighting Low Ambient/Task Lighting New and Underutilized Technology: Low Ambient/Task Lighting October 4, 2013 - 4:51pm Addthis The following information outlines key deployment considerations for low ambient/task lighting within the Federal sector. Benefits The low ambient/task lighting strategy improves the visual environment by adding controllable task fixtures that provide light directly where needed for a given task, while reducing the overhead (ambient) light level. Occupancy sensors can also be incorporated into the system. Application Low ambient/task lighting is applicable in most building categories. Key Factors for Deployment Low ambient/task lighting is suitable for most office spaces, including both cubicle and private office space environments, and should be

178

Independence Power and Light - Commercial Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Independence Power and Light - Commercial Energy Efficiency Rebate Independence Power and Light - Commercial Energy Efficiency Rebate Program Independence Power and Light - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Appliances & Electronics Commercial Lighting Lighting Maximum Rebate $20,000, or 30% of the total project cost annually per organization Program Info State Missouri Program Type Utility Rebate Program Rebate Amount High Performance T-8 Systems: $20-$30 Reduced-Wattage T-8 Systems: $20-$30 Standard T-8 Lamp: $2 Standard T-8 Electric Ballast: $10 400W HID Replacement (250W or less T8, T5, or T5HO Fluorescent): $75 Pulse Start Metal Halide Fixture: $50

179

Ameren Illinois - Lighting Rebates for Businesses | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

- Lighting Rebates for Businesses - Lighting Rebates for Businesses Ameren Illinois - Lighting Rebates for Businesses < Back Eligibility Commercial Fed. Government Industrial Local Government Multi-Family Residential Nonprofit State Government Savings Category Other Appliances & Electronics Commercial Lighting Lighting Maximum Rebate $600,000/year/facility Incentives $1-$200,000: paid at 100% Incentives $200,000- $600,000: paid at 50% Program Info Funding Source Illinois Energy Efficiency Portfolio Standard (EEPS) surcharge Expiration Date 5/31/2013 State Illinois Program Type Utility Rebate Program Rebate Amount Fluorescent U-Bend Relamp and Reballast: $0.25/watt reduced T12 to T8 Relamp and Reballast: $0.25/watt reduced T12 to T5 Fluorescent Fixture: $0.25/watt reduced T8 to reduced wattage T8 or T5 Relamp and Reballast: $0.40/watt reduced

180

Transformations in Lighting: The Fifth Annual Solid-State Lighting R&D Workshop  

Energy.gov (U.S. Department of Energy (DOE))

More than 300 SSL technology leaders from industry, research organizations, universities, and national laboratories gathered in Atlanta, GA, along with representatives from efficiency programs, utilities, and the lighting design community to participate in the DOE SSL R&D Workshop on January 29-31, 2008. DOE SSL Program Manager James Brodrick kicked off the workshop by highlighting recent signs of the progress and pace of SSL advances: the New Year's Eve debut of the new Times Square Ball, lit with Philips Luxeon LEDs; the first DOE Gateway demonstration of Beta LED streetlights in Oakland, CA; and the LR6 downlight from LED Lighting Fixtures, Inc., Grand Prize Winner in the 2007 Lighting for Tomorrow competition.

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Vacuum vapor deposition gun assembly  

DOE Patents (OSTI)

A vapor deposition gun assembly includes a hollow body having a cylindrical outer surface and an end plate for holding an adjustable heat sink, a hot hollow cathode gun, two magnets for steering the plasma from the gun into a crucible on the heat sink, and a shutter for selectively covering and uncovering the crucible.

Zeren, Joseph D. (Boulder, CO)

1985-01-01T23:59:59.000Z

182

LNG Vaporizer Utilizing Vacuum Steam Condensing  

Science Journals Connector (OSTI)

This report concerns the field test results of a new type of peak-shaving LNG vaporizer (VSV) whose heat source is ... heat of vacuum steam to vaporize and superheat LNG within heat transfer tubes. Prior to the.....

Y. Miyata; M. Hanamure; H. Kujirai; Y. Sato…

1991-01-01T23:59:59.000Z

183

Running-Film Vaporizer for LNG  

Science Journals Connector (OSTI)

Advances in welding technology and steel fabrication techniques have permitted the development of a new concept in cryogenic vaporizers—the running-film plate vaporizer. Although similar in heat transfer philosop...

H. H. West; G. L. Puckett

1975-01-01T23:59:59.000Z

184

Vapor Retarder Classification- Building America Top Innovation  

Energy.gov (U.S. Department of Energy (DOE))

This Building America Innovations profile describes research in vapor retarders. Since 2006 the IRC has permitted Class III vapor retarders like latex paint (see list above) in all climate zones under certain conditions thanks to research by Building America teams.

185

Vapor phase modifiers for oxidative coupling  

DOE Patents (OSTI)

Volatilized metal compounds retard vapor phase alkane conversion reactions in oxidative coupling processes that convert lower alkanes to higher hydrocarbons.

Warren, Barbara K. (Charleston, WV)

1991-01-01T23:59:59.000Z

186

Load regulating expansion fixture  

DOE Patents (OSTI)

A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils is disclosed. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components. 1 fig.

Wagner, L.M.; Strum, M.J.

1998-12-15T23:59:59.000Z

187

Load regulating expansion fixture  

DOE Patents (OSTI)

A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components.

Wagner, Lawrence M. (San Jose, CA); Strum, Michael J. (San Jose, CA)

1998-01-01T23:59:59.000Z

188

Coaxial test fixture  

DOE Patents (OSTI)

This invention pertains to arrangements for performing electrical tests on contact material samples, and in particular for testing contact material test samples in an evacuated environment under high current loads. Frequently, it is desirable in developing high-current separable contact material, to have at least a preliminary analysis of selected candidate conductor materials. Testing of material samples will hopefully identify materials unsuitable for high current electrical contact without requiring incorporation of the materials into a completed and oftentimes complex structure.

Praeg, W.F.

1984-03-30T23:59:59.000Z

189

Vapor Pressures and Heats of Vaporization of Primary Coal Tars  

Office of Scientific and Technical Information (OSTI)

/ PC92544-18 / PC92544-18 VAPOR PRESSURES AND HEATS OF VAPORIZATION OF PRIMARY COAL TARS FINAL REPORT Grant Dates: August, 1992 - November, 1996 Principal Authors: Eric M. Suuberg (PI) and Vahur Oja Report Submitted: April, 1997 Revised: July, 1997 Grant Number: DE-FG22-92PC92544 Report Submitted by: ERIC M. SUUBERG DIVISION OF ENGINEERING BROWN UNIVERSITY PROVIDENCE, RI 02912 TEL. (401) 863-1420 Prepared For: U. S. DEPT. OF ENERGY FEDERAL ENERGY TECHNOLOGY CENTER P.O. BOX 10940 PITTSBURGH, PA 15236 DR. KAMALENDU DAS, FETC, MORGANTOWN , WV TECHNICAL PROJECT OFFICER "US/DOE Patent Clearance is not required prior to the publication of this document" ii United States Government Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any

190

Photo-Electric Ionization of Caesium Vapor  

Science Journals Connector (OSTI)

Measurement of photo-electric ionization in gases.—The current from a filament, normally limited by space change, is increased by the presence of positive ions. As shown by Kingdon this effect may be greatly magnified if a small cathode is practically enclosed by the anode so that the ions are imprisoned. This method was used for the detection of photo-electric ionization. Besides possessing extreme sensitivity it is unaffected by photo-electric emission from the electrodes.Photo-electric effect in caesium vapor.—The change in thermionic current with the unresolved radiation from a mercury arc was measured as functions of the applied voltage, filament temperature, and vapor pressure. Then the photo-electric effect as a function of wave-length was studied using a monochromatic illuminator to disperse light from the arc or a Mazda lamp. The ionization per unit flux was found to increase with increasing wave-length to a sharp maximum at the limit 1s=3184A of the principal series, as is required by the Bohr theory. For longer wave-lengths the ionization decreased to about 10 percent at 3400A. Photo-excitation. The simple theory does not admit of ionization by wave-lengths greater than 3184A but the data are in qualitative agreement with the hypothesis that such radiation produces excited atoms which upon collision with other atoms acquire sufficient additional energy to become ionized. Hence, unlike an x-ray limit, the photo-ionization effect for a valence electron is not sharply discontinuous at the true threshold for direct ionization.Photo-ionization photometer and intensitometer. A tube of the type described, with suitable gases for the range of wave-length involved, may be used as a photometer or may be calibrated to measure intensity of radiation directly.

Paul D. Foote and F. L. Mohler

1925-08-01T23:59:59.000Z

191

Vapor deposition of tantalum and tantalum compounds  

SciTech Connect

Tantalum, and many of its compounds, can be deposited as coatings with techniques ranging from pure, thermal chemical vapor deposition to pure physical vapor deposition. This review concentrates on chemical vapor deposition techniques. The paper takes a historical approach. The authors review classical, metal halide-based techniques and current techniques for tantalum chemical vapor deposition. The advantages and limitations of the techniques will be compared. The need for new lower temperature processes and hence new precursor chemicals will be examined and explained. In the last section, they add some speculation as to possible new, low-temperature precursors for tantalum chemical vapor deposition.

Trkula, M. [Los Alamos National Lab., NM (United States). Materials Science and Technology Div.

1996-04-01T23:59:59.000Z

192

Means and method for vapor generation  

DOE Patents (OSTI)

A liquid, in heat transfer contact with a surface heated to a temperature well above the vaporization temperature of the liquid, will undergo a multiphase (liquid-vapor) transformation from 0% vapor to 100% vapor. During this transition, the temperature driving force or heat flux and the coefficients of heat transfer across the fluid-solid interface, and the vapor percentage influence the type of heating of the fluid--starting as "feedwater" heating where no vapors are present, progressing to "nucleate" heating where vaporization begins and some vapors are present, and concluding with "film" heating where only vapors are present. Unstable heating between nucleate and film heating can occur, accompanied by possibly large and rapid temperature shifts in the structures. This invention provides for injecting into the region of potential unstable heating and proximate the heated surface superheated vapors in sufficient quantities operable to rapidly increase the vapor percentage of the multiphase mixture by perhaps 10-30% and thereby effectively shift the multiphase mixture beyond the unstable heating region and up to the stable film heating region.

Carlson, Larry W. (Oswego, IL)

1984-01-01T23:59:59.000Z

193

Evanescent light-matter Interactions in Atomic Cladding Wave Guides  

E-Print Network (OSTI)

Alkali vapors, and in particular rubidium, are being used extensively in several important fields of research such as slow and stored light non-linear optics3 and quantum computation. Additionally, the technology of alkali vapors plays a major role in realizing myriad industrial applications including for example atomic clocks magentometers8 and optical frequency stabilization. Lately, there is a growing effort towards miniaturizing traditional centimeter-size alkali vapor cells. Owing to the significant reduction in device dimensions, light matter interactions are greatly enhanced, enabling new functionalities due to the low power threshold needed for non-linear interactions. Here, taking advantage of the mature Complimentary Metal-Oxide-Semiconductor (CMOS) compatible platform of silicon photonics, we construct an efficient and flexible platform for tailored light vapor interactions on a chip. Specifically, we demonstrate light matter interactions in an atomic cladding wave guide (ACWG), consisting of CMOS ...

Stern, Liron; Goykhman, Ilya; Levy, Uriel

2012-01-01T23:59:59.000Z

194

L&E: Participate in a field test for high-efficiency troffer lighting. |  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting & Electrical » Participate Lighting & Electrical » Participate in a field test for high efficiency troffer lighting Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Participate in a field test for high-efficiency troffer lighting 50% of all commercial fluorescent lighting fixtures are recessed troffers in 1'x4', 2'x2' and 2'x4' configurations, in operation for more than 10 hours a day on average and collectively consuming more than 87 TWh of electricity annually. The Lighting & Electrical team supported the market introduction of high-efficiency troffers by developing a specification that allows for

195

Wick for metal vapor laser  

DOE Patents (OSTI)

An improved wick for a metal vapor laser is made of a refractory metal cylinder, preferably molybdenum or tungsten for a copper laser, which provides the wicking surface. Alternately, the inside surface of the ceramic laser tube can be metalized to form the wicking surface. Capillary action is enhanced by using wire screen, porous foam metal, or grooved surfaces. Graphite or carbon, in the form of chunks, strips, fibers or particles, is placed on the inside surface of the wick to reduce water, reduce metal oxides and form metal carbides.

Duncan, David B. (Livermore, CA)

1992-01-01T23:59:59.000Z

196

Non-Vapor Compression HVAC Technologies Report  

Energy.gov (U.S. Department of Energy (DOE))

While vapor-compression technologies have served heating, ventilation, and air-conditioning (HVAC) needs very effectively, and have been the dominant HVAC technology for close to 100 years, the conventional refrigerants used in vapor-compression equipment contribute to global climate change when released to the atmosphere. The Building Technologies Office is evaluating low-global warming potential (GWP) alternatives to vapor-compression technologies.

197

Mercury Vapor (Kooten, 1987) | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor (Kooten, 1987) Mercury Vapor (Kooten, 1987) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor (Kooten, 1987) Exploration Activity Details Location Unspecified Exploration Technique Mercury Vapor Activity Date Usefulness useful DOE-funding Unknown Notes Surface soil-mercury surveys are an inexpensive and useful exploration tool for geothermal resources. ---- Surface geochemical surveys for mercury were conducted in 16 areas in 1979-1981 by ARCO Oil and Gas Company as part of its geothermal evaluation program. Three techniques used together have proved satisfactory in evaluating surface mercury data. These are contouring, histograms and cumulative frequency plots of the data. Contouring geochemical data and constructing histograms are standard

198

Vapor phase modifiers for oxidative coupling  

DOE Patents (OSTI)

Volatilized metal compounds are described which are capable of retarding vapor phase alkane conversion reactions in oxidative coupling processes that convert lower alkanes to higher hydrocarbons.

Warren, B.K.

1991-12-17T23:59:59.000Z

199

G-Band Vapor Radiometer Precipitable Water Vapor (GVRPWV) Value-Added Product  

SciTech Connect

The G-Band Vapor Radiometer Precipitable Water Vapor (GVRPWV) value-added product (VAP) computes precipitable water vapor using neural network techniques from data measured by the GVR. The GVR reports time-series measurements of brightness temperatures for four channels located at 183.3 ± 1, 3, 7, and 14 GHz.

Koontz, A; Cadeddu, M

2012-12-05T23:59:59.000Z

200

Slideshow: Flipping the Switch on LED Lighting for the National Mall |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Slideshow: Flipping the Switch on LED Lighting for the National Slideshow: Flipping the Switch on LED Lighting for the National Mall Slideshow: Flipping the Switch on LED Lighting for the National Mall January 31, 2012 - 3:05pm Addthis 1 of 8 Facing East toward the Capitol Building, LED retrofitted lights line the interior paths of the mall while preserving the architectural integrity of the original fixtures. Image: Energy Department Image | Photo by Quentin Kruger (Contractor) | Public Domain Date taken: 2012-01-30 06:00 2 of 8 Energy Secretary Steven Chu discusses the 65% savings on electric bills and lowered maintenance costs the National Parks Service is experiencing by switching to energy efficient LED lights. "Using energy-efficient LED light bulbs is an important way Americans can save money by saving energy," said

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant  

Open Energy Info (EERE)

MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant Program (Iowa) No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Summary Last modified on November 9, 2012. Financial Incentive Program Place Iowa Additional Place applies to MidAmerican Energy Name MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant Program Incentive Type Utility Grant Program Applicable Sector Local Government Eligible Technologies Lighting, Lighting Controls/Sensors, Induction Lighitng, LED Lighting Active Incentive Yes Implementing Sector Utility Energy Category Energy Efficiency Incentive Programs Amount Up to $5,000 Equipment Requirements Fixtures must have an efficiency rating equal to or greater than 66 lumens per watt as tested under Illuminating Engineering Society of North America LM-79-08 testing to qualify for a grant.

202

Slideshow: Flipping the Switch on LED Lighting for the National Mall |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Slideshow: Flipping the Switch on LED Lighting for the National Slideshow: Flipping the Switch on LED Lighting for the National Mall Slideshow: Flipping the Switch on LED Lighting for the National Mall January 31, 2012 - 3:05pm Addthis 1 of 8 Facing East toward the Capitol Building, LED retrofitted lights line the interior paths of the mall while preserving the architectural integrity of the original fixtures. Image: Energy Department Image | Photo by Quentin Kruger (Contractor) | Public Domain Date taken: 2012-01-30 06:00 2 of 8 Energy Secretary Steven Chu discusses the 65% savings on electric bills and lowered maintenance costs the National Parks Service is experiencing by switching to energy efficient LED lights. "Using energy-efficient LED light bulbs is an important way Americans can save money by saving energy," said

203

Quantitative organic vapor-particle sampler  

DOE Patents (OSTI)

A quantitative organic vapor-particle sampler for sampling semi-volatile organic gases and particulate components. A semi-volatile organic reversible gas sorbent macroreticular resin agglomerates of randomly packed microspheres with the continuous porous structure of particles ranging in size between 0.05-10 .mu.m for use in an integrated diffusion vapor-particle sampler.

Gundel, Lara (Berkeley, CA); Daisey, Joan M. (Walnut Creek, CA); Stevens, Robert K. (Cary, NC)

1998-01-01T23:59:59.000Z

204

LNG fire and vapor control system technologies  

SciTech Connect

This report provides a review of fire and vapor control practices used in the liquefied natural gas (LNG) industry. Specific objectives of this effort were to summarize the state-of-the-art of LNG fire and vapor control; define representative LNG facilities and their associated fire and vapor control systems; and develop an approach for a quantitative effectiveness evaluation of LNG fire and vapor control systems. In this report a brief summary of LNG physical properties is given. This is followed by a discussion of basic fire and vapor control design philosophy and detailed reviews of fire and vapor control practices. The operating characteristics and typical applications and application limitations of leak detectors, fire detectors, dikes, coatings, closed circuit television, communication systems, dry chemicals, water, high expansion foam, carbon dioxide and halogenated hydrocarbons are described. Summary descriptions of a representative LNG peakshaving facility and import terminal are included in this report together with typical fire and vapor control systems and their locations in these types of facilities. This state-of-the-art review identifies large differences in the application of fire and vapor control systems throughout the LNG industry.

Konzek, G.J.; Yasutake, K.M.; Franklin, A.L.

1982-06-01T23:59:59.000Z

205

Long-term evaluation of solid oxide fuel cell candidate materials in a 3-cell generic short stack fixture, Part II: sealing glass stability, microstructure and interfacial reactions.  

SciTech Connect

A generic solid oxide fuel cell stack test fixture was developed to evaluate candidate materials and processing methods under realistic conditions. Part I of the work addressed the stack fixture, seal system and cell performance of a 3-cell short stack tested at 800oC for 6000h. Commercial NiO-YSZ anode-supported thin YSZ electrolyte cells with LSM cathodes were used for assessment and were tested in constant current mode with dilute (~50% H2) fuel versus air. Part II of the work examined the sealing glass stability, microstructure development, interfacial reactions, and volatility issues. Part III of the work investigated the stability of Ce-(Mn,Co) spinel coating, AISI441 metallic interconnect, alumina coating, and cell degradation. After 6000h of testing, the refractory sealing glass YSO77 (Ba-Sr-Y-B-Si) showed desirable chemical compatibility with YSZ electrolyte in that no discernable interfacial reaction was identified, consistent with thermodynamic calculations. In addition, no glass penetration into the thin electrolyte was observed. At the aluminized AISI441 interface, the protective alumina coating appeared to be corroded by the sealing glass. Air side interactions appeared to be more severe than fuel side interactions. Metal species such as Cr, Mn, and Fe were detected in the glass, but were limited to the vicinity of the interface. No alkaline earth chromates were found at the air side. Volatility was also studied in a similar glass and weight loss in a wet reducing environment was determined. Using the steady-state volatility data, the life time (40,000h) weight loss of refractory sealing glass YSO77 was estimated to be less than 0.1 wt%.

Chou, Y. S.; Stevenson, Jeffry W.; Choi, Jung-Pyung

2014-03-15T23:59:59.000Z

206

ARM - Field Campaign - Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

govCampaignsWater Vapor IOP govCampaignsWater Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Water Vapor IOP 2000.09.18 - 2000.10.08 Lead Scientist : Henry Revercomb Data Availability Yes For data sets, see below. Description Scientific hypothesis: 1. Microwave radiometer (MWR) observations of the 22 GHz water vapor line can accurately constrain the total column amount of water vapor (assuming a calibration accuracy of 0.5 degC or better, which translates into 0.35 mm PWV). 2. Continuous profiling by Raman lidar provides a stable reference for handling sampling problems and observes a fixed column directly above the site only requiring a single height- independent calibration factor. 3. Agreement between the salt-bath calibrated in-situ probes, chilled

207

Energy balance in laser-irradiated vaporizing droplets  

Science Journals Connector (OSTI)

The interactions of vaporizing aerosols with a high energy laser beam are analyzed in the diffusive vaporization regime. This is the regime in which diffusive mass transport and...

Zardecki, Andrew; Armstrong, Robert L

1988-01-01T23:59:59.000Z

208

Ground Gravity Survey At Cove Fort Area - Vapor (Warpinski, Et...  

Open Energy Info (EERE)

Vapor (Warpinski, Et Al., 2004) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Gravity Survey At Cove Fort Area - Vapor (Warpinski, Et...

209

Hydrogen-Bond Acidic Polymers for Chemical Vapor Sensing. | EMSL  

NLE Websites -- All DOE Office Websites (Extended Search)

Acidic Polymers for Chemical Vapor Sensing. Hydrogen-Bond Acidic Polymers for Chemical Vapor Sensing. Abstract: A review with 171 references. Hydrogen-bond acidic polymers for...

210

Seeing the Light: LED Under-Cabinet and Recessed Downlights | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Seeing the Light: LED Under-Cabinet and Recessed Downlights Seeing the Light: LED Under-Cabinet and Recessed Downlights Seeing the Light: LED Under-Cabinet and Recessed Downlights August 2, 2010 - 10:42am Addthis Chris Stewart Senior Communicator at DOE's National Renewable Energy Laboratory I moved into my apartment about four years ago. Little by little, I've continued to make improvements that help me save money on my energy bills. I've: Applied weatherstripping to seal air leaks around windows Insulated my crawl space Installed storm windows to reduce air movement into and out of existing windows (I live in a historic district and can't replace my windows) Installed window shades to help with insulation Replaced my incandescent lighting fixtures with compact fluorescent lamps (CFLs) (I even purchased outdoor solar lights for my dad for Fathers Day.)

211

Recovering hydrocarbons from hydrocarbon-containing vapors  

DOE Patents (OSTI)

Values are recovered from a hydrocarbon-containing vapor by contacting the vapor with quench liquid consisting essentially of hydrocarbons to form a condensate and a vapor residue, the condensate and quench fluid forming a combined liquid stream. The combined liquid stream is mixed with a viscosity-lowering liquid to form a mixed liquid having a viscosity lower than the viscosity of the combined liquid stream to permit easy handling of the combined liquid stream. The quench liquid is a cooled portion of the mixed liquid. Viscosity-lowering liquid is separated from a portion of the mixed liquid and cycled to form additional mixed liquid.

Mirza, Zia I. (La Verne, CA); Knell, Everett W. (Los Alamitos, CA); Winter, Bruce L. (Danville, CA)

1980-09-30T23:59:59.000Z

212

Aerogel composites using chemical vapor infiltration  

NLE Websites -- All DOE Office Websites (Extended Search)

Aerogel composites using chemical vapor infiltration Aerogel composites using chemical vapor infiltration Title Aerogel composites using chemical vapor infiltration Publication Type Journal Article Year of Publication 1995 Authors Hunt, Arlon J., Michael R. Ayers, and Wanqing Cao Journal Journal of Non-Crystalline Solids Volume 185 Pagination 227-232 Abstract A new method to produce novel composite materials based on the use of aerogels as a starting material is described. Using chemical vapor infiltration, a variety of solid materials were thermally deposited into the open pore structure of aerogel. The resulting materials possess new and unusual properties including photoluminescence, magnetism and altered optical properties. An important characteristic of this preparation process is the very small size of the deposits that gives rise to new behaviors. Silicon deposits exhibit photoluminescence, indicating quantum confinement. Two or more phases may be deposited simultaneously and one or both chemically or thermally reacted to produce new structures.

213

Chemical vapor detection using nanomechanical platform  

Science Journals Connector (OSTI)

For high sensitive and multiplexed chemical analysis, an opto-mechanical detection platform has been built. To check the performance of the platform, we performed water vapor response measurements for ... sensors...

S. H. Lim

2007-11-01T23:59:59.000Z

214

Chemical vapor deposition of functionalized isobenzofuran polymers  

E-Print Network (OSTI)

This thesis develops a platform for deposition of polymer thin films that can be further tailored by chemical surface modification. First, we explore chemical vapor deposition of functionalized isobenzofuran films using ...

Olsson, Ylva Kristina

2007-01-01T23:59:59.000Z

215

Vapor Power Systems MAE 4263 Final Exam  

E-Print Network (OSTI)

Vapor Power Systems MAE 4263 Final Exam Wednesday, May 5, 2004 Prof. P.M. Moretti Key Instructions, then think, then write! 1. What is the dewpoint of the exhaust of your car, if the gasoline consists2 so that the mole fraction of water vapor is yH2 O = 9 9 + 8 + 47 = 0:14063 pH2 O = 0:14063 14

216

Data:9234ee6c-ab3c-4a30-871e-62483c7d9170 | Open Energy Information  

Open Energy Info (EERE)

ee6c-ab3c-4a30-871e-62483c7d9170 ee6c-ab3c-4a30-871e-62483c7d9170 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures -Breakaway Contemporary aluminum pole Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

217

Data:9018f71d-e30a-40f8-a7d4-85d3ce0cd33a | Open Energy Information  

Open Energy Info (EERE)

f71d-e30a-40f8-a7d4-85d3ce0cd33a f71d-e30a-40f8-a7d4-85d3ce0cd33a No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Pendant Lamp Fixtures -Standard Ornamental Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

218

Data:48315a97-195f-42a6-b597-ae2291f4caf9 | Open Energy Information  

Open Energy Info (EERE)

a97-195f-42a6-b597-ae2291f4caf9 a97-195f-42a6-b597-ae2291f4caf9 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Pendent Lamp Fixtures - Standard Ornamental Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

219

Data:143cabe5-c276-4257-81f2-81a410443184 | Open Energy Information  

Open Energy Info (EERE)

cabe5-c276-4257-81f2-81a410443184 cabe5-c276-4257-81f2-81a410443184 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Pendent Lamp Fixtures - Breakaway Base Ornamental Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

220

Data:8224e1ec-59f7-4b3e-a948-b7c1e69d7992 | Open Energy Information  

Open Energy Info (EERE)

e1ec-59f7-4b3e-a948-b7c1e69d7992 e1ec-59f7-4b3e-a948-b7c1e69d7992 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Mastarm Lamp Fixtures - Contemporary Aluminum Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Data:25132ac7-c487-49fd-bebb-2f7e82bccf95 | Open Energy Information  

Open Energy Info (EERE)

ac7-c487-49fd-bebb-2f7e82bccf95 ac7-c487-49fd-bebb-2f7e82bccf95 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Contemporary aluminum pole Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

222

Data:780b7783-57f3-4f68-ae9f-2dabf87ccf2e | Open Energy Information  

Open Energy Info (EERE)

783-57f3-4f68-ae9f-2dabf87ccf2e 783-57f3-4f68-ae9f-2dabf87ccf2e No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Pendent Lamp Fixture - Ornamental Pole - Company Owned - Residential Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

223

Data:097bd602-838d-4236-a421-3869e589b008 | Open Energy Information  

Open Energy Info (EERE)

bd602-838d-4236-a421-3869e589b008 bd602-838d-4236-a421-3869e589b008 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixture - Ornamental Metal Post Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

224

Data:15c8e854-dabc-4fe0-9199-a4234ddd31a5 | Open Energy Information  

Open Energy Info (EERE)

e854-dabc-4fe0-9199-a4234ddd31a5 e854-dabc-4fe0-9199-a4234ddd31a5 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Breakaway Base Contemporary Aluminum Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

225

Data:1930475c-e431-4492-94ce-c461d1003207 | Open Energy Information  

Open Energy Info (EERE)

5c-e431-4492-94ce-c461d1003207 5c-e431-4492-94ce-c461d1003207 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Mastarm Lamp Fixtures - Standard Steel/Concrete Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

226

Data:D914f14b-f2d3-4f6b-afe7-b3592ca41c4e | Open Energy Information  

Open Energy Info (EERE)

f14b-f2d3-4f6b-afe7-b3592ca41c4e f14b-f2d3-4f6b-afe7-b3592ca41c4e No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Contemporary Aluminum Pole - Residential Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

227

Data:8cd7d13a-9cc8-4a48-b3c2-36fa2423c2d3 | Open Energy Information  

Open Energy Info (EERE)

cd7d13a-9cc8-4a48-b3c2-36fa2423c2d3 cd7d13a-9cc8-4a48-b3c2-36fa2423c2d3 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Contemporary Aluminum Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

228

Data:Bce07014-bc93-4029-9f9c-757c54b71d14 | Open Energy Information  

Open Energy Info (EERE)

Bce07014-bc93-4029-9f9c-757c54b71d14 Bce07014-bc93-4029-9f9c-757c54b71d14 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Breakaway Base Steel/Concrete Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

229

Data:42b77f49-c689-4baf-94c8-fd4bf6c1b030 | Open Energy Information  

Open Energy Info (EERE)

f49-c689-4baf-94c8-fd4bf6c1b030 f49-c689-4baf-94c8-fd4bf6c1b030 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Lamp Fixtures - Ornamental Metal Pole Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

230

Data:2ca26386-c34a-418e-98b6-65135a256cfa | Open Energy Information  

Open Energy Info (EERE)

6386-c34a-418e-98b6-65135a256cfa 6386-c34a-418e-98b6-65135a256cfa No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Pendant Lamp Fixtures - Breakaway Base Standard Ornamental Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

231

Data:632c1b2a-49c4-48cc-bbbf-ef05c119725f | Open Energy Information  

Open Energy Info (EERE)

c1b2a-49c4-48cc-bbbf-ef05c119725f c1b2a-49c4-48cc-bbbf-ef05c119725f No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Mastarm Lamp Fixtures - Breakaway Base Standard Steel/Concrete Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

232

Data:6ce9733d-9d7d-4c16-b949-7ee57e287371 | Open Energy Information  

Open Energy Info (EERE)

ce9733d-9d7d-4c16-b949-7ee57e287371 ce9733d-9d7d-4c16-b949-7ee57e287371 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Ornamental Metal Post Pole Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

233

Data:C9bbb27c-f90a-4133-9c21-25fbb0ff0fa7 | Open Energy Information  

Open Energy Info (EERE)

bbb27c-f90a-4133-9c21-25fbb0ff0fa7 bbb27c-f90a-4133-9c21-25fbb0ff0fa7 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - MV Lamp Fixtures Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

234

Data:B0993536-b649-466f-b2b7-92bd7d6d30f2 | Open Energy Information  

Open Energy Info (EERE)

536-b649-466f-b2b7-92bd7d6d30f2 536-b649-466f-b2b7-92bd7d6d30f2 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Pendant Lamp Fixtures - Ornamental Pole - Residential Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

235

Data:16c12927-1686-4cc5-83a9-58827bff3a72 | Open Energy Information  

Open Energy Info (EERE)

927-1686-4cc5-83a9-58827bff3a72 927-1686-4cc5-83a9-58827bff3a72 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixture - Contemporary Aluminum Pole - Company Owned - Residential Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

236

Data:Afc304bc-e37c-4bb4-9604-0a625c3b1007 | Open Energy Information  

Open Energy Info (EERE)

Afc304bc-e37c-4bb4-9604-0a625c3b1007 Afc304bc-e37c-4bb4-9604-0a625c3b1007 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Pendent Lamp Fixtures - Standard Ornamental Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

237

Data:5d9bd42f-6353-4e87-8e65-9d378f3363f6 | Open Energy Information  

Open Energy Info (EERE)

bd42f-6353-4e87-8e65-9d378f3363f6 bd42f-6353-4e87-8e65-9d378f3363f6 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Mastarm Lamp Fixtures -Contemporary aluminum pole Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

238

Data:Af9d2db7-299a-4f61-a63e-eaa291e2ec6c | Open Energy Information  

Open Energy Info (EERE)

d2db7-299a-4f61-a63e-eaa291e2ec6c d2db7-299a-4f61-a63e-eaa291e2ec6c No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Lamp Fixture - Ornamental Metal Post Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

239

Data:F18470dd-5838-40ef-af68-8513b32b31f7 | Open Energy Information  

Open Energy Info (EERE)

8470dd-5838-40ef-af68-8513b32b31f7 8470dd-5838-40ef-af68-8513b32b31f7 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Mastarm Lamp Fixtures -Breakaway Contemporary aluminum pole Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

240

Data:01d32474-b6d4-4449-8c25-1ce0f2e3378a | Open Energy Information  

Open Energy Info (EERE)

474-b6d4-4449-8c25-1ce0f2e3378a 474-b6d4-4449-8c25-1ce0f2e3378a No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Breakaway Base Standard Steel Pole Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Data:025c3c33-5b22-4554-83b2-fc205f6331e0 | Open Energy Information  

Open Energy Info (EERE)

c33-5b22-4554-83b2-fc205f6331e0 c33-5b22-4554-83b2-fc205f6331e0 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Pendant Lamp Fixtures - Breakaway Base Standard Ornamental Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

242

Data:F9f56f8f-0094-4ff5-a7d7-29815c11045a | Open Energy Information  

Open Energy Info (EERE)

f8f-0094-4ff5-a7d7-29815c11045a f8f-0094-4ff5-a7d7-29815c11045a No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Mastarm Lamp Fixtures - Breakaway Base Contemporary Aluminum Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

243

Data:Ff8d6c70-5b8c-49ca-ba4a-650b80d3a10b | Open Energy Information  

Open Energy Info (EERE)

d6c70-5b8c-49ca-ba4a-650b80d3a10b d6c70-5b8c-49ca-ba4a-650b80d3a10b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Pendent Lamp Fixtures - Breakaway Base Ornamental Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

244

Data:B01ce61b-e9d8-49ee-ab97-5e762ab49bed | Open Energy Information  

Open Energy Info (EERE)

ce61b-e9d8-49ee-ab97-5e762ab49bed ce61b-e9d8-49ee-ab97-5e762ab49bed No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Lamp Fixtures - Standard Steel/Concrete Pole - Company Owned Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

245

Lighting in Residential and Commercial Buildings (1993 and 1995 Data)  

U.S. Energy Information Administration (EIA) Indexed Site

Types > 1995 CBECS Lighting Equipment Types > 1995 CBECS Lighting Equipment 1995 CBECS Lighting Equipment Profile Lighting Equipment - Type and Characteristics of Equipment Emits Found In Incandescent Incandescent Light Bulb Produces light by electrically heating a tungsten filament Includes energy-efficient incandescent bulbs, such as Reflector or R-Lamps (accent and task lighting), Parabolic Aluminized Reflector (PAR) lamps (flood and spot lighting), and Ellipsoidal Reflector (ER) lamps (recessed lighting) Highly inefficient because much of the energy is lost as heat 14-18 Lumens Per Watt (LPW) 14% of Lit Commercial Floorspace Standard Fluorescent Lighting with Magnetic Ballast Standard Fluorescent with Magnetic Ballast Produces light by passing electricity through mercury vapor, causing the fluorescent coating to glow or fluoresce

246

Light Portal  

Science Journals Connector (OSTI)

The Light Portal was designed to organize and mark the pedestrian paths that circumnavigate the rectangle of the...

2006-01-01T23:59:59.000Z

247

Light's twist  

Science Journals Connector (OSTI)

...equal to the optical power divided by the speed of light, and hence go unnoticed in our everyday lives...approaching object equal to the power in the light beam (P) divided by the speed of light. The movement of the approaching object does...

2014-01-01T23:59:59.000Z

248

Light Properties Light travels at the speed of light `c'  

E-Print Network (OSTI)

LIGHT!! #12;Light Properties Light travels at the speed of light `c' C = 3 x 108 m/s Or 190.nasa.gov #12;The speed of light The speed of light `c' is equal to the frequency ` times the wavelength,000 miles/second!! Light could travel around the world about 8 times in one second #12;What is light?? Light

Mojzsis, Stephen J.

249

Vapor Pressures and Vaporization, Sublimation, and Fusion Enthalpies of Some Fatty Acids  

E-Print Network (OSTI)

Vapor Pressures and Vaporization, Sublimation, and Fusion Enthalpies of Some Fatty Acids Joe A. Wilson and James S. Chickos* Department of Chemistry and Biochemistry, University of MissouriSt. Louis, St. Louis, Missouri 63121, United States *S Supporting Information ABSTRACT: Sublimation enthalpies

Chickos, James S.

250

Vapor Pressures and Vaporization Enthalpies of a Series of Dialkyl Phthalates by Correlation Gas Chromatography  

E-Print Network (OSTI)

Chromatography Chase Gobble and James Chickos* Department of Chemistry and Biochemistry University of Missouri-St. Louis, St. Louis Missouri 63121, United States Sergey P. Verevkin Department of Physical Chemistry: Experimental vapor pressures, vaporization, fusion and sublimation enthalpies of a number of dialkyl

Chickos, James S.

251

Lighting Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Purple LED lamp Purple LED lamp Lighting Systems Lighting research is aimed at improving the energy efficiency of lighting systems in buildings and homes across the nation. The goal is to reduce lighting energy consumption by 50% over twenty years by improving the efficiency of light sources, and controlling and delivering illumination so that it is available, where and when needed, and at the required intensity. Research falls into four main areas: Sources and Ballasts, Light Distribution Systems, Controls and Communications, and Human Factors. Contacts Francis Rubinstein FMRubinstein@lbl.gov (510) 486-4096 Links Lighting Research Group Batteries and Fuel Cells Buildings Energy Efficiency Applications Commercial Buildings Cool Roofs and Heat Islands Demand Response Energy Efficiency Program and Market Trends

252

Metal organic chemical vapor deposition of 111-v compounds on silicon  

DOE Patents (OSTI)

Expitaxial composite comprising thin films of a Group III-V compound semiconductor such as gallium arsenide (GaAs) or gallium aluminum arsenide (GaAlAs) on single crystal silicon substrates are disclosed. Also disclosed is a process for manufacturing, by chemical deposition from the vapor phase, epitaxial composites as above described, and to semiconductor devices based on such epitaxial composites. The composites have particular utility for use in making light sensitive solid state solar cells.

Vernon, Stanley M. (Wellesley, MA)

1986-01-01T23:59:59.000Z

253

Edison Revisited: Should we use DC circuits for lighting in commercial buildings?  

Science Journals Connector (OSTI)

We examine the economic feasibility of using dedicated DC circuits to operate lighting in commercial buildings. We compare light-emitting diodes (LEDs) and fluorescents that are powered by either a central DC power supply or traditional AC grid electricity, with and without solar photovoltaics (PV) and battery back-up. Using DOE performance targets for \\{LEDs\\} and solar PV, we find that by 2012 \\{LEDs\\} have the lowest levelized annualized cost (LAC). If a DC voltage standard were developed, so that each LED fixture's driver could be eliminated, \\{LACs\\} could decrease, on average, by 5% compared to AC \\{LEDs\\} with a driver in each fixture. DC circuits in grid-connected PV-powered LED lighting systems can lower the total unsubsidized capital costs by 4–21% and \\{LACs\\} by 2–21% compared to AC grid-connected PV LEDs. Grid-connected PV \\{LEDs\\} may match the LAC of grid-powered fluorescents by 2013. This outcome depends more on manufacturers' ability to produce \\{LEDs\\} that follow DOE's lamp production cost and efficacy targets, than on reducing power electronics costs for DC building circuits and voltage standardization. Further work is needed to better understand potential safety risks with DC distribution and to remove design, installation, permitting, and regulatory barriers.

Brinda A. Thomas; Inês L. Azevedo; Granger Morgan

2012-01-01T23:59:59.000Z

254

ARM - Field Campaign - Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

govCampaignsWater Vapor IOP govCampaignsWater Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Water Vapor IOP 1996.09.10 - 1996.09.30 Lead Scientist : Henry Revercomb For data sets, see below. Summary SCHEDULE This IOP will be conducted from September 10 - 30, 1996 (coincident with the Fall ARM-UAV IOP). Instruments that do not require supervision will be operated continuously during this period. Instruments that do require supervision are presently planned to be operated for 8-hour periods each day. Because it is necessary to cover as broad a range of environmental conditions as possible, the daily 8-hour period will be shifted across the diurnal cycle as deemed appropriate during the IOP (but will be maintained as a contiguous 8-hour block).

255

atmospheric water vapor | OpenEI  

Open Energy Info (EERE)

atmospheric water vapor atmospheric water vapor Dataset Summary Description (Abstract): Monthly Average Solar Resource for 2-axis tracking concentrating collectors for Mexico, Central America, and the Caribbean Islands. (Purpose): Provide information on the solar resource potential for the data domain. The insolation values represent the average solar energy available to a concentrating collector, such as a dish collector, which tracks the sun continuously. Source NREL Date Released July 31st, 2006 (8 years ago) Date Updated October 30th, 2007 (7 years ago) Keywords atmospheric water vapor Carribean Islands Central America DNI GIS Mexico NREL GEF solar SWERA UNEP Data application/zip icon Download Shapefile (zip, 247.8 KiB) text/csv icon Download Data (csv, 370.6 KiB) Quality Metrics Level of Review Some Review

256

atmoshperic water vapor | OpenEI  

Open Energy Info (EERE)

atmoshperic water vapor atmoshperic water vapor Dataset Summary Description (Abstract): Monthly Average Solar Resource for flat-plate collectors tilted at latitude for China. Source NREL Date Released April 12th, 2005 (9 years ago) Date Updated October 30th, 2007 (7 years ago) Keywords atmoshperic water vapor China GEF GIS NREL solar SWERA TILT UNEP Data application/zip icon Download Shapefile (zip, 625.6 KiB) text/csv icon Download Data (csv, 704.1 KiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Time Period 01/01/1985 - 12/31/1991 License License Open Data Commons Public Domain Dedication and Licence (PDDL) Comment Rate this dataset Usefulness of the metadata Average vote Your vote Usefulness of the dataset Average vote Your vote Ease of access

257

Vapor characterization of Tank 241-C-103  

SciTech Connect

The Westinghouse Hanford Company Tank Vapor Issue Resolution Program has developed, in cooperation with Northwest Instrument Systems, Inc., Oak Ridge National Laboratory, Oregon Graduate Institute of Science and Technology, Pacific Northwest Laboratory, and Sandia National Laboratory, the equipment and expertise to characterize gases and vapors in the high-level radioactive waste storage tanks at the Hanford Site in south central Washington State. This capability has been demonstrated by the characterization of the tank 241-C-103 headspace. This tank headspace is the first, and for many reasons is expected to be the most problematic, that will be characterized (Osborne 1992). Results from the most recent and comprehensive sampling event, sample job 7B, are presented for the purpose of providing scientific bases for resolution of vapor issues associated with tank 241-C-103. This report is based on the work of Clauss et al. 1994, Jenkins et al. 1994, Ligotke et al. 1994, Mahon et al. 1994, and Rasmussen and Einfeld 1994. No attempt has been made in this report to evaluate the implications of the data presented, such as the potential impact of headspace gases and vapors to tank farm workers health. That and other issues will be addressed elsewhere. Key to the resolution of worker health issues is the quantitation of compounds of toxicological concern. The Toxicology Review Panel, a panel of Pacific Northwest Laboratory experts in various areas, of toxicology, has chosen 19 previously identified compounds as being of potential toxicological concern. During sample job 7B, the sampling and analytical methodology was validated for this preliminary list of compounds of toxicological concern. Validation was performed according to guidance provided by the Tank Vapor Conference Committee, a group of analytical chemists from academic institutions and national laboratories assembled and commissioned by the Tank Vapor Issue Resolution Program.

Huckaby, J.L. [Westinghouse Hanford Co., Richland, WA (United States); Story, M.S. [Northwest Instrument Systems, Inc. Richland, WA (United States)

1994-06-01T23:59:59.000Z

258

Thermal electric vapor trap arrangement and method  

DOE Patents (OSTI)

A technique for trapping vapor within a section of a tube is disclosed herein. This technique utilizes a conventional, readily providable thermal electric device having a hot side and a cold side and means for powering the device to accomplish this. The cold side of this device is positioned sufficiently close to a predetermined section of the tube and is made sufficiently cold so that any condensable vapor passing through the predetermined tube section is condensed and trapped, preferably within the predetermined tube section itself. 4 figs.

Alger, T.

1988-03-15T23:59:59.000Z

259

Dimension-sensitive optical responses of electromagnetically induced transparency vapor in a waveguide  

Science Journals Connector (OSTI)

A three-level EIT (electromagnetically induced transparency) vapor is used to manipulate the transparency and absorption properties of the probe light in a waveguide. The most remarkable feature of the present scheme is such that the optical responses resulting from both electromagnetically induced transparency and large spontaneous emission enhancement are very sensitive to the frequency detunings of the probe light as well as to the small changes of the waveguide dimension. The potential applications of the dimension- and dispersion-sensitive EIT responses are discussed, and the sensitivity limits of some waveguide-based sensors, including electric absorption modulator, optical switch, wavelength sensor, and sensitive magnetometer, are analyzed.

Jian Qi Shen and Sailing He

2006-12-28T23:59:59.000Z

260

Lighting Renovations  

Energy.gov (U.S. Department of Energy (DOE))

When undertaking a lighting renovation in a Federal building, daylighting is the primary renewable energy opportunity. Photovoltaics (PV) also present an excellent opportunity. While this guide...

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Cerenkov Light  

ScienceCinema (OSTI)

The bright blue glow from nuclear reactors is Cerenkov light. Karl Slifer describes how nuclear physicists can use this phenomenon to study the nucleus of the atom.

Slifer, Karl

2014-05-22T23:59:59.000Z

262

Eastern Iowa Light & Power Coop | Open Energy Information  

Open Energy Info (EERE)

Coop Coop Jump to: navigation, search Name Eastern Iowa Light & Power Coop Place Iowa Utility Id 5605 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes ISO MISO Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100W High Pressure Sodium Lighting 175W Mercury Vapor Lighting 250W High Pressure Sodium Lighting 400W Mercury Vapor Lighting Heat Plus Space Heating Service Commercial Large General Service Commercial Large General Service- Time of Use Commercial Large Power Service Industrial

263

Environmental Chemistry at Vapor/Water Interfaces  

E-Print Network (OSTI)

Environmental Chemistry at Vapor/Water Interfaces: Insights from Vibrational Sum Frequency Generation Spectroscopy Aaron M. Jubb, Wei Hua, and Heather C. Allen Department of Chemistry, The Ohio State/0505-0107$20.00 Keywords salts, lipids, atmospheric chemistry, ion binding, oxidation Abstract The chemistry that occurs

264

Advancing Explosives Detection Capabilities: Vapor Detection  

ScienceCinema (OSTI)

A new, PNNL-developed method provides direct, real-time detection of trace amounts of explosives such as RDX, PETN and C-4. The method selectively ionizes a sample before passing the sample through a mass spectrometer to detect explosive vapors. The method could be used at airports to improve aviation security.

Atkinson, David

2014-07-24T23:59:59.000Z

265

Program performs vapor-liquid equilibrium calculations  

SciTech Connect

A program designed for the Hewlett-Packard HP-41CV or 41C calculators solves basic vapor-liquid equilibrium problems, including figuring the dewpoint, bubblepoint, and equilibrium flash. The algorithm uses W.C. Edmister's method for predicting ideal-solution K values.

Rice, V.L.

1982-06-28T23:59:59.000Z

266

Synchroton X-Ray Studies of Liquid-Vapor Interfaces  

Science Journals Connector (OSTI)

The variation of density across the liquid-vapor interface from essentially zero density far out in the vapor phase to a homogeneous density deep in the liquid phase can be determined by X-ray reflectivity mea...

J. Als-Nielsen

1988-01-01T23:59:59.000Z

267

Vapor intrusion modeling : limitations, improvements, and value of information analyses  

E-Print Network (OSTI)

Vapor intrusion is the migration of volatile organic compounds (VOCs) from a subsurface source into the indoor air of an overlying building. Vapor intrusion models, including the Johnson and Ettinger (J&E) model, can be ...

Friscia, Jessica M. (Jessica Marie)

2014-01-01T23:59:59.000Z

268

Estimating the Atmospheric Water Vapor Content from Sun Photometer Measurements  

Science Journals Connector (OSTI)

The differential absorption technique for estimating columnar water vapor values from the analysis of sunphotometric measurements with wide- and narrowband interferential filters centered near 0.94 ?m is discussed and adapted. Water vapor line ...

Artemio Plana-Fattori; Michel Legrand; Didier Tanré; Claude Devaux; Anne Vermeulen; Philippe Dubuisson

1998-08-01T23:59:59.000Z

269

OPTIMIZATION OF INJECTION INTO VAPOR-DOMINATED GEOTHERMAL  

E-Print Network (OSTI)

given by U.S. Department of Energy, Geothermal Division. #12;vii Table of Contents ABSTRACTOPTIMIZATION OF INJECTION INTO VAPOR-DOMINATED GEOTHERMAL RESERVOIRS CONSIDERING ADSORPTION governing the behavior of vapor- dominated geothermal reservoirs. These mechanisms affect both

Stanford University

270

Residential Lighting End-Use Consumption Study: Estimation Framework and Initial Estimates  

SciTech Connect

The U.S. DOE Residential Lighting End-Use Consumption Study is an initiative of the U.S. Department of Energy’s (DOE’s) Solid-State Lighting Program that aims to improve the understanding of lighting energy usage in residential dwellings. The study has developed a regional estimation framework within a national sample design that allows for the estimation of lamp usage and energy consumption 1) nationally and by region of the United States, 2) by certain household characteristics, 3) by location within the home, 4) by certain lamp characteristics, and 5) by certain categorical cross-classifications (e.g., by dwelling type AND lamp type or fixture type AND control type).

Gifford, Will R.; Goldberg, Miriam L.; Tanimoto, Paulo M.; Celnicker, Dane R.; Poplawski, Michael E.

2012-12-01T23:59:59.000Z

271

Northern Lights  

NLE Websites -- All DOE Office Websites (Extended Search)

Northern Lights Northern Lights Nature Bulletin No. 178-A February 6, 1965 Forest Preserve District of Cook County Seymour Simon, President Roland F. Eisenbeis, Supt. of Conservation NORTHERN LIGHTS To a person seeing the Aurora Borealis or "northern lights" for the first time, it is an uncanny awe-inspiring spectacle. Sometimes it begins as a glow of red on the northern horizon, ominously suggesting a great fire, gradually changing to a curtain of violet-white, or greenish-yellow light extending from east to west. Some times this may be transformed to appear as fold upon fold of luminous draperies that march majestically across the sky; sometimes as a vast multitude of gigantic flaming swords furiously slashing at the heavens; sometimes as a flowing crown with long undulating colored streamers fanning downward and outward.

272

Apparent Temperature Dependence on Localized Atmospheric Water Vapor  

E-Print Network (OSTI)

Apparent Temperature Dependence on Localized Atmospheric Water Vapor Matthew Montanaroa, Carl), hence water vapor is the primary constituent of concern. The tower generates a localized water vapor, Office B108, Aiken, SC, USA ABSTRACT The atmosphere is a critical factor in remote sensing. Radiance from

Salvaggio, Carl

273

Fusion bonding and alignment fixture  

DOE Patents (OSTI)

An improved vacuum fusion bonding structure and process for aligned bonding of large area glass plates, patterned with microchannels and access holes and slots, for elevated glass fusion temperatures. Vacuum pumpout of all the components is through the bottom platform which yields an untouched, defect free top surface which greatly improves optical access through this smooth surface. Also, a completely non-adherent interlayer, such as graphite, with alignment and location features is located between the main steel platform and the glass plate pair, which makes large improvements in quality, yield, and ease of use, and enables aligned bonding of very large glass structures.

Ackler, Harold D. (Sunnyvale, CA); Swierkowski, Stefan P. (Livermore, CA); Tarte, Lisa A. (Livermore, CA); Hicks, Randall K. (Stockton, CA)

2000-01-01T23:59:59.000Z

274

Advanced Membrane Systems: Recovering Wasteful and Hazardous Fuel Vapors at the Gasoline Tank  

Energy.gov (U.S. Department of Energy (DOE))

Case study covering Compact Membrane Systems, Inc. and its membrane vapor processor that recovers fuel vapors from gasoline refueling.

275

Table lamp with dynamically controlled lighting distribution and uniformly illuminated luminous shade  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) or other lamps arranged vertically, i.e. one lamp above the other, with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum ensures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. In a particular configuration, the reflective septum is bowl shaped, with the upper CFL sitting in the bowl, and a luminous shade hanging down from the bowl. The lower CFL provides both task lighting and uniform shade luminance. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. However, other types of lamps, including incandescent, halogen, and LEDs can also be used in the fixture. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2002-01-01T23:59:59.000Z

276

Techniques for optically compressing light intensity ranges  

DOE Patents (OSTI)

A pin hole camera assembly for use in viewing an object having a relatively large light intensity range, for example a crucible containing molten uranium in an atomic vapor laser isotope separator (AVLIS) system is disclosed herein. The assembly includes means for optically compressing the light intensity range appearing at its input sufficient to make it receivable and decipherable by a standard video camera. A number of different means for compressing the intensity range are disclosed. These include the use of photogray glass, the use of a pair of interference filters, and the utilization of a new liquid crystal notch filter in combination with an interference filter.

Rushford, Michael C. (Livermore, CA)

1989-01-01T23:59:59.000Z

277

Techniques for optically compressing light intensity ranges  

DOE Patents (OSTI)

A pin hole camera assembly for use in viewing an object having a relatively large light intensity range, for example a crucible containing molten uranium in an atomic vapor laser isotope separator (AVLIS) system is disclosed herein. The assembly includes means for optically compressing the light intensity range appearing at its input sufficient to make it receivable and decipherable by a standard video camera. A number of different means for compressing the intensity range are disclosed. These include the use of photogray glass, the use of a pair of interference filters, and the utilization of a new liquid crystal notch filter in combination with an interference filter. 18 figs.

Rushford, M.C.

1989-03-28T23:59:59.000Z

278

Solid-State Lighting: LED Lighting Facts  

NLE Websites -- All DOE Office Websites (Extended Search)

Market-Based Programs Printable Version Share this resource Send a link to Solid-State Lighting: LED Lighting Facts to someone by E-mail Share Solid-State Lighting: LED Lighting Facts on Facebook Tweet about Solid-State Lighting: LED Lighting Facts on Twitter Bookmark Solid-State Lighting: LED Lighting Facts on Google Bookmark Solid-State Lighting: LED Lighting Facts on Delicious Rank Solid-State Lighting: LED Lighting Facts on Digg Find More places to share Solid-State Lighting: LED Lighting Facts on AddThis.com... LED Lighting Facts CALiPER Program Standards Development Technical Information Network Gateway Demonstrations Municipal Consortium Design Competitions LED Lighting Facts LED lighting facts - A Program of the U.S. DOE DOE's LED Lighting Facts® program showcases LED products for general

279

Precision micro drilling with copper vapor lasers  

SciTech Connect

The authors have developed a copper vapor laser based micro machining system using advanced beam quality control and precision wavefront tilting technologies. Micro drilling has been demonstrated through percussion drilling and trepanning using this system. With a 30 W copper vapor laser running at multi-kHz pulse repetition frequency, straight parallel holes with size varying from 500 microns to less than 25 microns and with aspect ratio up to 1:40 have been consistently drilled on a variety of metals with good quality. For precision trepanned holes, the hole-to-hole size variation is typically within 1% of its diameter. Hole entrance and exit are both well defined with dimension error less than a few microns. Materialography of sectioned holes shows little (sub-micron scale) recast layer and heat affected zone with surface roughness within 1--2 microns.

Chang, J.J.; Martinez, M.W.; Warner, B.E.; Dragon, E.P.; Huete, G.; Solarski, M.E.

1994-09-02T23:59:59.000Z

280

Copper vapor laser modular packaging assembly  

DOE Patents (OSTI)

A modularized packaging arrangement for one or more copper vapor lasers and associated equipment is disclosed herein. This arrangement includes a single housing which contains the laser or lasers and all their associated equipment except power, water and neon, and means for bringing power, water, and neon which are necessary to the operation of the lasers into the container for use by the laser or lasers and their associated equipment.

Alger, Terry W. (Tracy, CA); Ault, Earl R. (Dublin, CA); Moses, Edward I. (Castro Valley, CA)

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

EECBG Success Story: Lighting Retrofit Improving Visibility, Saving Energy  

Energy.gov (U.S. Department of Energy (DOE))

Muscatine, Iowa is replacing 300 high-pressure sodium cobra head streetlights with LED fixtures, thanks to an Energy Efficiency and Conservation Block Grant. Learn more.

282

Data:Aadf309e-0c12-4dcc-aee7-866d020b663a | Open Energy Information  

Open Energy Info (EERE)

Aadf309e-0c12-4dcc-aee7-866d020b663a Aadf309e-0c12-4dcc-aee7-866d020b663a No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Independence, Missouri (Utility Company) Effective date: 2013/07/01 End date if known: Rate name: Public Street Lighting Service - HPSV Double Mastarm Lamp - Standard Steel/Concrete Pole Sector: Lighting Description: To the City of Independence for all Public Street Lighting Service under which the street lighting pole/fixtures were originally installed by the Department prior to May 1, 1999. When (a) existing Mercury Vapor street lighting fixtures are converted to High Pressure Sodium Vapor fixtures or (b) existing Mercury Vapor and High Pressure Sodium Vapor street lighting pole/fixtures are replaced

283

Development of Nb{sub 3}Sn Cavity Vapor Diffusion Deposition System  

SciTech Connect

Nb{sub 3}Sn is a BCS superconductors with the superconducting critical temperature higher than that of niobium, so theoretically it surpasses the limitations of niobium in RF fields. The feasibility of technology has been demonstrated at 1.5 GHz with Nb{sub 3}Sn vapor deposition technique at Wuppertal University. The benefit at these frequencies is more pronounced at 4.2 K, where Nb{sub 3}Sn coated cavities show RF resistances an order of magnitude lower than that of niobium. At Jefferson Lab we started the development of Nb{sub 3}Sn vapor diffusion deposition system within an R\\&D development program towards compact light sources. Here we present the current progress of the system development.

Eremeev, Grigory V.; Macha, Kurt M.; Clemens, William A.; Park, HyeKyoung; Williams, R. Scott

2014-02-01T23:59:59.000Z

284

Application of atomic vapor laser isotope separation to the enrichment of mercury  

SciTech Connect

Workers at GTE/Sylvania have shown that the efficiency of fluorescent lighting may be markedly improved using mercury that has been enriched in the /sup 196/Hg isotope. A 5% improvement in the efficiency of fluorescent lighting in the United States could provide a savings of approx. 1 billion dollars in the corresponding reduction of electrical power consumption. We will discuss the results of recent work done at our laboratory to develop a process for enriching mercury. The discussion will center around the results of spectroscopic measurements of excited state lifetimes, photoionization cross sections and isotope shifts. In addition, we will discuss the mercury separator and supporting laser mesurements of the flow properties of mercury vapor. We will describe the laser system which will provide the photoionization and finally discuss the economic details of producing enriched mercury at a cost that would be attractive to the lighting industry.

Crane, J.K.; Erbert, G.V.; Paisner, J.A.; Chen, H.L.; Chiba, Z.; Beeler, R.G.; Combs, R.; Mostek, S.D.

1986-09-01T23:59:59.000Z

285

Data:4bfd510c-3f22-483c-a328-13250b69d47a | Open Energy Information  

Open Energy Info (EERE)

Data Data Edit with form History Facebook icon Twitter icon » Data:4bfd510c-3f22-483c-a328-13250b69d47a No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Sulphur Springs Valley E C Inc Effective date: 2013/03/18 End date if known: Rate name: Street Lighting: 150 Watt HPS - Single/Wood * Sector: Lighting Description: Customer provided Facilities and Cooperative Owned and Maintained Lighting Service. Applies only to lights presently installed. All new street lighting installed shall be H.P. Sodium. As ordinary replacement of Incandescent and Mercury Vapor fixtures is required, they shall be replaced with comparable Sodium fixtures. All fixtures installed shall be subject to meeting municipal or county lighting ordinances.

286

Data:86292828-2f51-4762-87e9-1d89693ca6b3 | Open Energy Information  

Open Energy Info (EERE)

Data Data Edit with form History Facebook icon Twitter icon » Data:86292828-2f51-4762-87e9-1d89693ca6b3 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Sulphur Springs Valley E C Inc Effective date: 2013/03/18 End date if known: Rate name: Street Lighting: 175 Watt MV - Double/Steel * Sector: Lighting Description: Customer provided Facilities and Cooperative Owned and Maintained Lighting Service. Applies only to lights presently installed. All new street lighting installed shall be H.P. Sodium. As ordinary replacement of Incandescent and Mercury Vapor fixtures is required, they shall be replaced with comparable Sodium fixtures. All fixtures installed shall be subject to meeting municipal or county lighting ordinances.

287

Data:D3f812da-815b-4586-9486-b29e0092bbd7 | Open Energy Information  

Open Energy Info (EERE)

Data Data Edit with form History Facebook icon Twitter icon » Data:D3f812da-815b-4586-9486-b29e0092bbd7 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Sulphur Springs Valley E C Inc Effective date: 2013/03/18 End date if known: Rate name: Street Lighting: 175 Watt MV - Single/Wood Sector: Lighting Description: Cooperative provided Facilities and Cooperative Owned and Maintained Lighting Service. Applies only to lights presently installed. All new street lighting installed shall be H.P. Sodium. As ordinary replacement of Incandescent and Mercury Vapor fixtures is required, they shall be replaced with comparable Sodium fixtures. All fixtures installed shall be subject to meeting municipal or county lighting ordinances.

288

Data:Dc5d06f3-dd89-4d36-bbe1-fd8b2a3981f7 | Open Energy Information  

Open Energy Info (EERE)

Data Data Edit with form History Facebook icon Twitter icon » Data:Dc5d06f3-dd89-4d36-bbe1-fd8b2a3981f7 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Sulphur Springs Valley E C Inc Effective date: 2013/03/18 End date if known: Rate name: Street Lighting: 175 Watt MV - Single/Steel Sector: Lighting Description: Customer provided Facilities and Cooperative Owned and Maintained Lighting Service. Applies only to lights presently installed. All new street lighting installed shall be H.P. Sodium. As ordinary replacement of Incandescent and Mercury Vapor fixtures is required, they shall be replaced with comparable Sodium fixtures. All fixtures installed shall be subject to meeting municipal or county lighting ordinances.

289

Long-term evaluation of solid oxide fuel cell candidate materials in a 3-cell generic stack test fixture, part III: Stability and microstructure of Ce-(Mn,Co)-spinel coating, AISI441 interconnect, alumina coating, cathode and anode  

Science Journals Connector (OSTI)

Abstract A generic solid oxide fuel cell stack test fixture was developed to evaluate candidate materials and processing under realistic conditions. Part III of the work investigated the stability of Ce-(Mn,Co) spinel coating, AISI441 metallic interconnect, alumina coating, and cell's degradation. After 6000 h test, the spinel coating showed densification with some diffusion of Cr. At the metal interface, segregation of Si and Ti was observed, however, no continuous layer formed. The alumina coating for perimeter sealing areas appeared more dense and thick at the air side than the fuel side. Both the spinel and alumina coatings remained bonded. EDS analysis of Cr within the metal showed small decrease in concentration near the coating interface and would expect to cause no issue of Cr depletion. Inter-diffusion of Ni, Fe, and Cr between spot-welded Ni wire and AISI441 interconnect was observed and Cr-oxide scale formed along the circumference of the weld. The microstructure of the anode and cathode was discussed relating to degradation of the top and middle cells. Overall, the Ce-(Mn,Co) spinel coating, alumina coating, and AISI441 steel showed the desired long-term stability and the developed generic stack fixture proved to be a useful tool to validate candidate materials for SOFC.

Yeong-Shyung Chou; Jeffry W. Stevenson; Jung-Pyung Choi

2014-01-01T23:59:59.000Z

290

Evaluation of a single cell and candidate materials with high water content hydrogen in a generic solid oxide fuel cell stack test fixture, Part II: materials and interface characterization  

SciTech Connect

A generic solid oxide fuel cell (SOFC) test fixture was developed to evaluate candidate materials under realistic conditions. A commerical 50 mm x 50 mm NiO-YSZ anode supported thin YSZ electrolyte cell with lanthanum strontium manganite (LSM) cathode was tested to evaluate the stability of candidate materials. The cell was tested in two stages at 800oC: stage I of low (~3% H2O) humidity and stage II of high (~30% H2O) humidity hydrogen fuel at constant voltage or constant current mode. Part I of the work was published earlier with information of the generic test fixture design, materials, cell performance, and optical post-mortem analysis. In part II, detailed microstructure and interfacial characterizations are reported regarding the SOFC candidate materials: (Mn,Co)-spinel conductive coating, alumina coating for sealing area, ferritic stainless steel interconnect, refractory sealing glass, and their interactions with each other. Overall, the (Mn,Co)-spinel coating was very effective in minimizing Cr migration. No Cr was identified in the cathode after 1720h at 800oC. Aluminization of metallic interconnect also proved to be chemically compatible with alkaline-earth silicate sealing glass. The details of interfacial reaction and microstructure development are discussed.

Chou, Y. S.; Stevenson, Jeffry W.; Choi, Jung-Pyung

2013-01-01T23:59:59.000Z

291

Federal Energy Management Program: Covered Product Category: Luminaires  

NLE Websites -- All DOE Office Websites (Extended Search)

Luminaires (Light Fixtures) to someone by E-mail Luminaires (Light Fixtures) to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Luminaires (Light Fixtures) on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Luminaires (Light Fixtures) on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Luminaires (Light Fixtures) on Google Bookmark Federal Energy Management Program: Covered Product Category: Luminaires (Light Fixtures) on Delicious Rank Federal Energy Management Program: Covered Product Category: Luminaires (Light Fixtures) on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Luminaires (Light Fixtures) on AddThis.com... Energy-Efficient Products Federal Requirements

292

Data:Af639f2b-ec48-4602-87ed-873b3ae13d31 | Open Energy Information  

Open Energy Info (EERE)

Box Fixture- 31 Foot pole) Sector: Lighting Description: *One Shoe Box Fixture with 31 Foot Fiberglass pole. All Decorative Lighting is subject to a ten year minimum contract...

293

Data:E28b0165-9de0-4e49-b99b-543ccbaeb9a8 | Open Energy Information  

Open Energy Info (EERE)

Box Fixtures- 31 Foot pole) Sector: Lighting Description: *Two Shoe Box Fixtures with 31 Foot Fiberglass pole. All Decorative Lighting is subject to a ten year minimum contract...

294

Data:F2257f25-b98e-45fd-b0ec-e07448329e91 | Open Energy Information  

Open Energy Info (EERE)

Fixture- 12 Foot Fluted pole) Sector: Lighting Description: *One Acorn Fixture with 12 Foot Fluted pole. All Decorative Lighting is subject to a ten year minimum contract...

295

Data:74c53d26-7282-470d-9c7e-774d73bff051 | Open Energy Information  

Open Energy Info (EERE)

if known: Rate name: Security Lighting- Decorative- HPS 100 Watt (Traditional Fixture- 15 Foot pole) Sector: Lighting Description: *Traditional Fixture with 15 Foot Fiberglass...

296

Data:898e47db-d45a-4017-bcf5-33c1739730b5 | Open Energy Information  

Open Energy Info (EERE)

if known: Rate name: Security Lighting- Decorative- HPS 100 Watt (Traditional Fixture- 24 Foot pole) Sector: Lighting Description: *Traditional Fixture with 24 Foot Fiberglass...

297

Data:C717fdbe-3b9f-4ba4-aa4c-96cd9afbcfed | Open Energy Information  

Open Energy Info (EERE)

Box Fixtures-31 Foot pole) Sector: Lighting Description: *Three Shoe Box Fixtures with 31 Foot Fiberglass pole. All Decorative Lighting is subject to a ten year minimum contract...

298

Data:6eea9c97-9e14-4783-a37e-f0922fd77e99 | Open Energy Information  

Open Energy Info (EERE)

Acorn Fixture- 15 Foot pole) Sector: Lighting Description: *One Acorn Fixture with 15 Foot Fiberglass pole. All Decorative Lighting is subject to a ten year minimum contract...

299

Data:Ba3dc825-fd8e-411d-84ca-8c371e29a92e | Open Energy Information  

Open Energy Info (EERE)

Box Fixtures- 31 Foot pole) Sector: Lighting Description: *Four Shoe Box Fixtures with 31 Foot Fiberglass pole. All Decorative Lighting is subject to a ten year minimum contract...

300

Replacement Costs and Cleaning & Service Charges for ResidenceHalls  

E-Print Network (OSTI)

Incandescent Light Fixture $130.00 each Incandescent Light Fixture Globe $82.00 each Exit Sign $440.00 each

Shyy, Wei

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Light's twist  

Science Journals Connector (OSTI)

...Glasgow G12 8QQ, UK An invited Perspective to mark the election of Miles Padgett to the fellowship of the Royal Society in 2014. That...energy and momentum flow within light beams can twist to form vortices such as eddies in a stream. These...

2014-01-01T23:59:59.000Z

302

ARM - Field Campaign - Fall 1997 Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

Water Vapor IOP Water Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Fall 1997 Water Vapor IOP 1997.09.15 - 1997.10.05 Lead Scientist : Henry Revercomb For data sets, see below. Summary The Water Vapor IOP was conducted as a follow-up to a predecessor IOP on water vapor held in September 1996. This IOP relied heavily on both ground-based guest and CART instrumentation and in-situ aircraft and tethered sonde/kite measurements. Primary operational hours were from 6 p.m. Central until at least midnight, with aircraft support normally from about 9 p.m. until midnight when available. However, many daytime measurements were made to support this IOP. The first Water Vapor IOP primarily concentrated on the atmosphere's lowest

303

G-Band Vapor Radiometer Profiler (GVRP) Handbook  

SciTech Connect

The G-Band Vapor Radiometer Profiler (GVRP) provides time-series measurements of brightness temperatures from 15 channels between 170 and 183.310 GHz. Atmospheric emission in this spectral region is primarily due to water vapor, with some influence from liquid water. Channels between 170.0 and 176.0 GHz are particularly sensitive to the presence of liquid water. The sensitivity to water vapor of the 183.31-GHz line is approximately 30 times higher than at the frequencies of the two-channel microwave radiometer (MWR) for a precipitable water vapor (PWV) amount of less than 2.5 mm. Measurements from the GVRP instrument are therefore especially useful during low-humidity conditions (PWV < 5 mm). In addition to integrated water vapor and liquid water, the GVRP can provide low-resolution vertical profiles of water vapor in very dry conditions.

Caddeau, MP

2010-06-23T23:59:59.000Z

304

Vapor port and groundwater sampling well  

DOE Patents (OSTI)

A method and apparatus has been developed for combining groundwater monitoring wells with unsaturated-zone vapor sampling ports. The apparatus allows concurrent monitoring of both the unsaturated and the saturated zone from the same well at contaminated areas. The innovative well design allows for concurrent sampling of groundwater and volatile organic compounds (VOCs) in the vadose (unsaturated) zone from a single well, saving considerable time and money. The sample tubes are banded to the outer well casing during installation of the well casing.

Hubbell, Joel M. (Idaho Falls, ID); Wylie, Allan H. (Idaho Falls, ID)

1996-01-01T23:59:59.000Z

305

Chemical vapor deposition of epitaxial silicon  

DOE Patents (OSTI)

A single chamber continuous chemical vapor deposition (CVD) reactor is described for depositing continuously on flat substrates, for example, epitaxial layers of semiconductor materials. The single chamber reactor is formed into three separate zones by baffles or tubes carrying chemical source material and a carrier gas in one gas stream and hydrogen gas in the other stream without interaction while the wafers are heated to deposition temperature. Diffusion of the two gas streams on heated wafers effects the epitaxial deposition in the intermediate zone and the wafers are cooled in the final zone by coolant gases. A CVD reactor for batch processing is also described embodying the deposition principles of the continuous reactor.

Berkman, Samuel (Florham Park, NJ)

1984-01-01T23:59:59.000Z

306

Recovery of benzene in an organic vapor monitor  

E-Print Network (OSTI)

solid adsorbents available (silica gel, activated alumina, etc. ), activated charcoal is most frequently utilized. Activated charcoal has retentivity for sorbed vapors several times that of silica gel and it displays a selectivity for organic vapors... (diffusion rate) of the vapor molecules to the sur- face of the adsorbent. The adsorption process determine how effective the adsorbent collects and holds the contam- inant on the surface of the activated charcoal. Recovery of the contaminant from...

Krenek, Gregory Joel

2012-06-07T23:59:59.000Z

307

Texas Electric Lighting Report  

NLE Websites -- All DOE Office Websites (Extended Search)

electric lighting electric lighting The SNAP House's lighting design aims for elegant simplicity in concept, use, and maintenance. Throughout the house, soft, ambient light is juxtaposed with bright, direct task lighting. All ambient and most task lighting is integrated directly into the architectural design of the house. An accent light wall between the bedroom and bathroom provides a glowing light for nighttime navigation.

308

Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) | Open Energy  

Open Energy Info (EERE)

Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) Exploration Activity Details Location Haleakala Volcano Area Exploration Technique Mercury Vapor Activity Date Usefulness not indicated DOE-funding Unknown Notes The field survey program on the northwest rift zone consisted of soil mercury and radon emanometry surveys, groundwater temperature and chemistry studies, Schlumberger resistivity soundings and self-potential profiles. Geophysical and geochemical surveys along this rift (southwest) were limited by difficult field conditions and access limitations. The geophysical program consisted of one Schlumberger sounding, one

309

Mercury Vapor At Vale Hot Springs Area (Varekamp & Buseck, 1983...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Vale Hot Springs Area (Varekamp & Buseck, 1983) Exploration Activity Details...

310

Mercury Vapor At Breitenbush Hot Springs Area (Varekamp & Buseck...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Breitenbush Hot Springs Area (Varekamp & Buseck, 1983) Exploration Activity...

311

Mercury Vapor At Mickey Hot Springs Area (Varekamp & Buseck,...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Mickey Hot Springs Area (Varekamp & Buseck, 1983) Exploration Activity...

312

Mercury Vapor At Desert Peak Area (Varekamp & Buseck, 1983) ...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Desert Peak Area (Varekamp & Buseck, 1983) Exploration Activity Details...

313

Mercury Vapor At Socorro Mountain Area (Kooten, 1987) | Open...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Socorro Mountain Area (Kooten, 1987) Exploration Activity Details Location...

314

Mercury Vapor At Lassen Volcanic National Park Area (Varekamp...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Lassen Volcanic National Park Area (Varekamp & Buseck, 1983) Exploration...

315

Thermal Performance of a Double-Tube Type Lng Vaporizer  

Science Journals Connector (OSTI)

This report concerns the confirmed test results and method of analysis of the thermal performance of a double-tube type LNG vaporizer (DTV). The DTV is a...

Y. Miyata; T. Miura; S. Kasahara; H. Shohtani…

1994-01-01T23:59:59.000Z

316

Optimal Control of Vapor Extraction of Heavy Oil.  

E-Print Network (OSTI)

??Vapor extraction (Vapex) process is an emerging technology for viscous oil recovery that has gained much attention in the oil industry. However, the oil production… (more)

Muhamad, Hameed (Author)

2012-01-01T23:59:59.000Z

317

Geographic Information System At Cove Fort Area - Vapor (Nash...  

Open Energy Info (EERE)

navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Geographic Information System At Cove Fort Area - Vapor (Nash, Et Al., 2002) Exploration Activity Details...

318

Raman Lidar Measurements of Aerosols and Water Vapor During the...  

NLE Websites -- All DOE Office Websites (Extended Search)

modifications reduced but could not eliminate these adverse effects. The Raman lidar water vapor (aerosol extinction) measurements produced by these modified algorithms were,...

319

Thermal Gradient Holes At Cove Fort Area - Vapor (Warpinski,...  

Open Energy Info (EERE)

Warpinski, Et Al., 2004) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Thermal Gradient Holes At Cove Fort Area - Vapor (Warpinski, Et Al.,...

320

Ground Magnetics At Cove Fort Area - Vapor (Warpinski, Et Al...  

Open Energy Info (EERE)

Vapor (Warpinski, Et Al., 2004) Exploration Activity Details Location Cove Fort Geothermal Area Exploration Technique Ground Magnetics Activity Date Usefulness useful DOE-funding...

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Spray structures and vaporizing characteristics of a GDI fuel spray  

Science Journals Connector (OSTI)

The spray structures and distribution characteristics of liquid and vapor phases in non-evaporating and evaporating Gasoline Direct Injection (GDI) fuel sprays were investigated using Laser Induced...

Dong-Seok Choi; Gyung-Min Choi; Duck-Jool Kim

2002-07-01T23:59:59.000Z

322

McMinnville Water and Light - Commercial Energy Efficiency Rebate Programs  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

McMinnville Water and Light - Commercial Energy Efficiency Rebate McMinnville Water and Light - Commercial Energy Efficiency Rebate Programs McMinnville Water and Light - Commercial Energy Efficiency Rebate Programs < Back Eligibility Commercial Industrial Savings Category Appliances & Electronics Commercial Lighting Lighting Manufacturing Program Info State Oregon Program Type Utility Rebate Program Rebate Amount McMinnville Water and Light Company Provider McMinnville Water and Light McMinnville Water and Light Company offers a variety of rebates for commercial and industrial customers to make energy efficient improvements to eligible facilities. MW&L offers rebates in three categories: Lighting retrofits, motor replacements, and process efficiency. Past lighting projects have included fluorescent lighting retrofits, mercury vapor

323

Integration of Global Positioning System and Scanning Water Vapor Radiometers for Precipitable Water Vapor and Cloud Liquid Path Estimates  

NLE Websites -- All DOE Office Websites (Extended Search)

Integration of Global Positioning System and Scanning Integration of Global Positioning System and Scanning Water Vapor Radiometers for Precipitable Water Vapor and Cloud Liquid Path Estimates V. Mattioli and P. Basili Department of Electronic and Information Engineering University of Perugia Perugia, Italy E. R. Westwater Cooperative Institute for Research in Environmental Sciences University of Colorado National Oceanic and Atmospheric Administration Environmental Technology Laboratory Boulder, Colorado Introduction In recent years the Global Positioning System (GPS) has proved to be a reliable instrument for measuring precipitable water vapor (PWV) (Bevis et al. 1992), offering an independent source of information on water vapor when compared with microwave radiometers (MWRs), and/or radiosonde

324

Vapor and gas sampling of Single-Shell Tank 241-T-111 using the vapor sampling system  

SciTech Connect

This document presents sampling data resulting from the January 20, 1995, sampling of SST 241-T-111 using the vapor sampling system.

Caprio, G.S.

1995-09-01T23:59:59.000Z

325

Vapor and gas sampling of single-shell tank 241-BY-112 using the vapor sampling system  

SciTech Connect

This document presents sampling data from the November 18, 1994, sampling of SST 241-BY-112 using the vapor sampling system.

Caprio, G.S.

1995-09-20T23:59:59.000Z

326

Energy Star Lighting Verification Program (Program for the Evaluation and Analysis of Residential Lighting)  

SciTech Connect

The Program for the Evaluation and Analysis of Residential Lighting (PEARL) is a watchdog program. It was created in response to complaints received by utility program managers about the performance of certain Energy Star lighting products being promoted within their service territories and the lack of a self-policing mechanism within the lighting industry that would ensure the reliability of these products and their compliance with ENERGY STAR specifications. To remedy these problems, PEARL purchases and tests products that are available to the consumers in the marketplace. The Lighting Research Center (LRC) tests the selected products against the corresponding Energy Star specifications. This final report summarizes the experimental procedure and results of all cycles (Cycles 1 through 8) of PEARL program from the beginning of year 2000 to the end of 2007, along with the description of apparatus used, equipment calibration process, experimental methodology, and research findings from the testing. In each cycle of PEARL program, PEARL Board selects a list of Compact Fluorescent Lamp (CFL) and Residential Lighting Fixture (RLF) models that are Energy Star qualified. In Cycle 5, Cycle 7, and Cycle 8, no fixture models were selected. After that PEARL sponsors procure product samples for each selected model from different stores and locations in the retail market and send them to LRC for testing. LRC then receive and select the samples, and test them against Energy Star specifications. After the testing LRC analyze and report the results to PEARL Board. Totally 185 models of CFL and 52 models of RLF were tested in PEARL program. Along with the evolution of the Energy Star specifications from year 2000 to 2003, parameters that were required by Energy Star changed during the eight years of PEARL program. The testing parameters and number of samples tested in PEARL program also changed during this time. For example, in Cycle 1, three samples of each models were tested for their photometric and electrical parameters only; in Cycle 2, 1000-hour Lumen Maintenance and the Rapid Cycle Stress Test was added and an additional set of six samples of each models were tested for Rapid Cycle Stress Test. Also, Cycle 2 data analysis included the testing and verification results against both the 'then existing' specification dated 2000 and the 'then new' specification dated 8/9/2001. In Cycle 3, Lumen Maintenance at 40% life was added and the number of samples for photometric and electrical testing was increased to five. In Cycle 6, the number of samples for photometric and electrical testing increased again to ten so that five of them were tested in base-up position and five in base-down position. A total of 2375 CFL samples were tested in PEARL program, out of the more than 3000 CFL samples that were purchased for the testing purpose of this program.

Conan O'Rourke; Yutao Zhou

2007-12-31T23:59:59.000Z

327

Informal Report . VAPOR DETECTION OF TRAFFICKING OF CONTRABAND MONEY-  

E-Print Network (OSTI)

I BNL- 62834 Informal Report . VAPOR DETECTION OF TRAFFICKING OF CONTRABAND MONEY-· [D VAPOR DETECTION OF TRAFFICKING OF CONTRABAND MONEY- A DISCUSSION OF TECHNICAL FEASIBILITY Concept MONEY --A DISCUSSION OF TECHNICAL FEASffiILITY Russell N. Dietz, Head Tracer Technology Center

328

RESONANT FARADAY ROTATION IN A HOT LITHIUM VAPOR  

E-Print Network (OSTI)

RESONANT FARADAY ROTATION IN A HOT LITHIUM VAPOR By SCOTT RUSSELL WAITUKAITIS A Thesis Submitted: #12;Abstract I describe a study of Faraday rotation in a hot lithium vapor. I begin by dis- cussing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.3 The Lithium Oven and Solenoid . . . . . . . . . . . . . . . . . 7 3 Theoretical Framework

Cronin, Alex D.

329

FLAMMABILITY CHARACTERISTICS OF COMBUSTIBLE GASES AND VAPORS  

Office of Scientific and Technical Information (OSTI)

Bulletin 627 Bulletin 627 BUREAU o b MINES FLAMMABILITY CHARACTERISTICS OF COMBUSTIBLE GASES AND VAPORS By Michael G. Zabetakis DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency Thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement,

330

New Regenerative Cycle for Vapor Compression Refrigeration  

Office of Scientific and Technical Information (OSTI)

SCIENTIFIC REPORT SCIENTIFIC REPORT Title Page Project Title: New Regenerative Cycle for Vapor Compression Refrigeration DOE Award Number: DE-FG36-04GO14327 Document Title: Final Scientific Report Period Covered by Report: September 30, 2004 to September 30, 2005 Name and Address of Recipient Organization: Magnetic Development, Inc., 68 Winterhill Road, Madison, CT 06443, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Contact Information: Mark J. Bergander, Ph.D., P.E., Principal Investigator, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Project Objective (as stated in the proposal): The main objective of this project is to confirm on a well-instrumented prototype the theoretically derived claims of higher efficiency and coefficient

331

Chemical vapor deposition of group IIIB metals  

DOE Patents (OSTI)

Coatings of Group IIIB metals and compounds thereof are formed by chemical vapor deposition, in which a heat decomposable organometallic compound of the formula given in the patent where M is a Group IIIB metal, such as lanthanum or yttrium and R is a lower alkyl or alkenyl radical containing from 2 to about 6 carbon atoms, with a heated substrate which is above the decomposition temperature of the organometallic compound. The pure metal is obtained when the compound of the formula 1 is the sole heat decomposable compound present and deposition is carried out under nonoxidizing conditions. Intermetallic compounds such as lanthanum telluride can be deposited from a lanthanum compound of formula 1 and a heat decomposable tellurium compound under nonoxidizing conditions.

Erbil, A.

1989-11-21T23:59:59.000Z

332

Lighting Test Facilities  

NLE Websites -- All DOE Office Websites (Extended Search)

Custom Projects Lighting Test Facilities SSL Guidelines Industrial Federal Agriculture LED Street and Area Lighting Field Test of Exterior LED Down Lights Abstract Outdoor...

333

Light Water Reactor Sustainability  

NLE Websites -- All DOE Office Websites (Extended Search)

4 Light Water Reactor Sustainability ACCOMPLISHMENTS REPORT 2014 Accomplishments Report | Light Water Reactor Sustainability 2 T he mission of the Light Water Reactor...

334

Gas Separation Using Organic-Vapor-Resistent Membranes In Conjunctin With Organic-Vapor-Selective Membranes  

DOE Patents (OSTI)

A process for treating a gas mixture containing at least an organic compound gas or vapor and a second gas, such as natural gas, refinery off-gas or air. The process uses two sequential membrane separation steps, one using membrane selective for the organic compound over the second gas, the other selective for the second gas over the organic vapor. The second-gas-selective membranes use a selective layer made from a polymer having repeating units of a fluorinated polymer, and demonstrate good resistance to plasticization by the organic components in the gas mixture under treatment, and good recovery after exposure to liquid aromatic hydrocarbons. The membrane steps can be combined in either order.

Baker, Richard W. (Palo Alto, CA); Pinnau, Ingo (Palo Alto, CA); He, Zhenjie (Fremont, CA); Da Costa, Andre R. (Menlo Park, CA); Daniels, Ramin (San Jose, CA); Amo, Karl D. (Mountain View, CA); Wijmans, Johannes G. (Menlo Park, CA)

2003-06-03T23:59:59.000Z

335

Hybrid Vapor Compression Adsorption System: Thermal Storage Using Hybrid Vapor Compression Adsorption System  

SciTech Connect

HEATS Project: UTRC is developing a new climate-control system for EVs that uses a hybrid vapor compression adsorption system with thermal energy storage. The targeted, closed system will use energy during the battery-charging step to recharge the thermal storage, and it will use minimal power to provide cooling or heating to the cabin during a drive cycle. The team will use a unique approach of absorbing a refrigerant on a metal salt, which will create a lightweight, high-energy-density refrigerant. This unique working pair can operate indefinitely as a traditional vapor compression heat pump using electrical energy, if desired. The project will deliver a hot-and-cold battery that provides comfort to the passengers using minimal power, substantially extending the driving range of EVs.

None

2012-01-04T23:59:59.000Z

336

E-Print Network 3.0 - atomic vapor laser Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

with the exception of pagination. IEEE TRANSACTIONS ON PLASMA SCIENCE 1 Summary: vapor, atomic physics and vapor ionization, absorption reflection in a heated plasma layer, and...

337

E-Print Network 3.0 - atom vapor cells Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

rotation in the vapor cell due to inten- sity-induced birefringence in the rubidium atomic vapor. While... Super efficient absorption filter for quantum memory using atomic...

338

Light Bodies: Exploring Interactions with Responsive Lights  

E-Print Network (OSTI)

reinterpretation of street lighting. Before fixed infrastructure illuminated cities at night, people carried Urban street lighting today is a networked, fixed infrastructure that relies on the electrical grid. WeLight Bodies: Exploring Interactions with Responsive Lights Susanne Seitinger MIT Media Laboratory

Hunt, Galen

339

Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting Lighting Lighting When you're shopping for lightbulbs, compare lumens and use the Lighting Facts label to be sure you're getting the amount of light, or level of brightness, you want. You can save money and energy while lighting your home and still maintaining good light quantity and quality. Consider energy-efficient lighting options to use the same amount of light for less money. Learn strategies for comparing and buying lighting products and using them efficiently. Featured Lighting Choices to Save You Money Light your home for less money while using the same amount of light. How Energy-Efficient Light Bulbs Compare with Traditional Incandescents Energy-efficient light bulbs are available today and could save you about $50 per year in energy costs when you replace 15 traditional incandescent bulbs in your home.

340

Preliminary assessment of halogenated alkanes as vapor-phase tracers  

SciTech Connect

New tracers are needed to evaluate the efficiency of injection strategies in vapor-dominated environments. One group of compounds that seems to meet the requirements for vapor-phase tracing are the halogenated alkanes (HCFCs). HCFCs are generally nontoxic, and extrapolation of tabulated thermodynamic data indicate that they will be thermally stable and nonreactive in a geothermal environment. The solubilities and stabilities of these compounds, which form several homologous series, vary according to the substituent ratios of fluorine, chlorine, and hydrogen. Laboratory and field tests that will further define the suitability of HCFCs as vapor-phase tracers are under way.

Adams, Michael C.; Moore, Joseph N.; Hirtz, Paul

1991-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Mercury Vapor At Medicine Lake Area (Kooten, 1987) | Open Energy  

Open Energy Info (EERE)

Kooten, 1987) Kooten, 1987) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Medicine Lake Area (Kooten, 1987) Exploration Activity Details Location Medicine Lake Area Exploration Technique Mercury Vapor Activity Date Usefulness could be useful with more improvements DOE-funding Unknown References Gerald K. Van Kooten (1987) Geothermal Exploration Using Surface Mercury Geochemistry Retrieved from "http://en.openei.org/w/index.php?title=Mercury_Vapor_At_Medicine_Lake_Area_(Kooten,_1987)&oldid=386431" Category: Exploration Activities What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation:

342

Catalytic Reactor For Oxidizing Mercury Vapor  

DOE Patents (OSTI)

A catalytic reactor (10) for oxidizing elemental mercury contained in flue gas is provided. The catalyst reactor (10) comprises within a flue gas conduit a perforated corona discharge plate (30a, b) having a plurality of through openings (33) and a plurality of projecting corona discharge electrodes (31); a perforated electrode plate (40a, b, c) having a plurality of through openings (43) axially aligned with the through openings (33) of the perforated corona discharge plate (30a, b) displaced from and opposing the tips of the corona discharge electrodes (31); and a catalyst member (60a, b, c, d) overlaying that face of the perforated electrode plate (40a, b, c) opposing the tips of the corona discharge electrodes (31). A uniformly distributed corona discharge plasma (1000) is intermittently generated between the plurality of corona discharge electrode tips (31) and the catalyst member (60a, b, c, d) when a stream of flue gas is passed through the conduit. During those periods when corona discharge (1000) is not being generated, the catalyst molecules of the catalyst member (60a, b, c, d) adsorb mercury vapor contained in the passing flue gas. During those periods when corona discharge (1000) is being generated, ions and active radicals contained in the generated corona discharge plasma (1000) desorb the mercury from the catalyst molecules of the catalyst member (60a, b, c, d), oxidizing the mercury in virtually simultaneous manner. The desorption process regenerates and activates the catalyst member molecules.

Helfritch, Dennis J. (Baltimore, MD)

1998-07-28T23:59:59.000Z

343

Laser techniques for studying chemical vapor deposition  

SciTech Connect

Chemical vapor deposition (CVD) is widely used to produce thin films for microelectronics, protective coatings and other materials processing applications. Despite the large number of applications, however, little is known about the fundamental chemistry and physics of most CVD processes. CVD recipes have generally been determined empirically, but as process requirements become more stringent, a more basic understanding will be needed to improve reactor design and speed process optimization. In situ measurements of the reacting gas are important steps toward gaining such an understanding, both from the standpoint of characterizing the reactor and testing models of a CVD process. Our work, a coordinated program of experimental and theoretical research in the fundamental mechanisms of CVD, illustrates the application of laser techniques to the understanding of a CVD system. We have used a number of laser-based techniques to probe CVD systems and have compared our measurements with predictions from computer models, primarily for the silane CVD system. The silane CVD model solves the two-dimensional, steady-state boundary layer equations of fluid flow coupled to 26 elementary chemical reactions describing the thermal decomposition of silane and the subsequent reactions of intermediate species that result in the deposition of a silicon film.

Ho, P.; Breiland, W.G.; Coltrin, M.E.

1990-01-01T23:59:59.000Z

344

Architectural Lighting Analysis in Virtual Lighting Laboratory  

NLE Websites -- All DOE Office Websites (Extended Search)

Architectural Lighting Analysis in Virtual Lighting Laboratory Architectural Lighting Analysis in Virtual Lighting Laboratory Speaker(s): Mehlika Inanici Date: July 7, 2003 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Satkartar K. Kinney Virtual Lighting Laboratory is a Radiance-based lighting analysis tool and methodology that proposes transformations in the utilization of computer visualization in lighting analysis and design decision-making. It is a computer environment, where the user has been provided with matrices of illuminance and luminance values extracted from high dynamic range images. The principal idea is to provide the laboratory to the designer and researcher to explore various lighting analysis techniques instead of imposing limited number of predetermined metrics. In addition, it introduces an analysis approach for temporal and spatial lighting

345

Method and apparatus for simulating atomospheric absorption of solar energy due to water vapor and CO.sub.2  

DOE Patents (OSTI)

A method and apparatus for improving the accuracy of the simulation of sunlight reaching the earth's surface includes a relatively small heated chamber having an optical inlet and an optical outlet, the chamber having a cavity that can be filled with a heated stream of CO.sub.2 and water vapor. A simulated beam comprising infrared and near infrared light can be directed through the chamber cavity containing the CO.sub.2 and water vapor, whereby the spectral characteristics of the beam are altered so that the output beam from the chamber contains wavelength bands that accurately replicate atmospheric absorption of solar energy due to atmospheric CO.sub.2 and moisture.

Sopori, Bhushan L. (Denver, CO)

1995-01-01T23:59:59.000Z

346

Method and apparatus for simulating atmospheric absorption of solar energy due to water vapor and CO{sub 2}  

DOE Patents (OSTI)

A method and apparatus for improving the accuracy of the simulation of sunlight reaching the earth`s surface includes a relatively small heated chamber having an optical inlet and an optical outlet, the chamber having a cavity that can be filled with a heated stream of CO{sub 2} and water vapor. A simulated beam comprising infrared and near infrared light can be directed through the chamber cavity containing the CO{sub 2} and water vapor, whereby the spectral characteristics of the beam are altered so that the output beam from the chamber contains wavelength bands that accurately replicate atmospheric absorption of solar energy due to atmospheric CO{sub 2} and moisture. 8 figs.

Sopori, B.L.

1995-06-20T23:59:59.000Z

347

ARM - Field Campaign - Arctic Winter Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

govCampaignsArctic Winter Water Vapor IOP govCampaignsArctic Winter Water Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Arctic Winter Water Vapor IOP 2004.03.09 - 2004.04.09 Lead Scientist : Ed Westwater Data Availability http://www.etl.noaa.gov/programs/2004/wviop/data will contain quicklooks of all of the data. For data sets, see below. Summary During the IOP, the Ground-based Scanning Radiometer of NOAA/ETL, and the ARM MicroWave Radiometer and Microwave Profiler, yielded excellent data over a range of conditions. In all, angular-scanned and calibrated radiometric data from 22.345 to 380 GHz were taken. The Precipitable Water Vapor varied about an order of magnitude from 1 to 10 mm, and surface temperatures varied from about -10 to -40 deg. Celcius. Vaisala RS90

348

Overview of the ARM/FIRE Water Vapor Experiment (AFWEX)  

NLE Websites -- All DOE Office Websites (Extended Search)

Overview of the ARM/FIRE Water Vapor Overview of the ARM/FIRE Water Vapor Experiment (AFWEX) D. C. Tobin, H. E. Revercomb, and D. D. Turner University of Wisconsin-Madison Madison, Wisconsin Introduction An overview of the ARM/FIRE Water Vapor Experiment (AFWEX) is given. This field experiment was conducted during November-December 2000 near the central ground-based Atmospheric Radiation Measurement (ARM) site in north central Oklahoma, and was sponsored jointly by the ARM, the National Aeronautics and Space Administration (NASA) First ISCCP Regional Experiment (FIRE), and the National Polar-orbiting Operational Environmental Satellite System (NPOESS) programs. Its primary goal was to collect accurate measurements of upper-level (~8 to 12 km) water vapor near the ground-based ARM site. These data are being used to determine the accuracy of measurements that are

349

Initiated chemical vapor deposition of functional polyacrylic thin films  

E-Print Network (OSTI)

Initiated chemical vapor deposition (iCVD) was explored as a novel method for synthesis of functional polyacrylic thin films. The process introduces a peroxide initiator, which can be decomposed at low temperatures (<200?C) ...

Mao, Yu, 1975-

2005-01-01T23:59:59.000Z

350

Low Level Heat Recovery Through Heat Pumps and Vapor Recompression  

E-Print Network (OSTI)

The intent of this paper is to examine the methods and economics of recovering low level heat through heat pumps and vapor recompression. Actual commercially available equipment is considered to determine the near-term and future economic viability...

Gilbert, J.

1980-01-01T23:59:59.000Z

351

Applications of Mechanical Vapor Recompression to Evaporation and Crystallization  

E-Print Network (OSTI)

there is no boiler plant available or when electrical power is priced competitively in comparison to steam. Vapor recompression is accomplished using centrifugal, axial-flow, or positive displacement compressors and these compressors can be powered by electricity...

Outland, J. S.

352

Enabling integration of vapor-deposited polymer thin films  

E-Print Network (OSTI)

Initiated Chemical Vapor Deposition (iCVD) is a versatile, one-step process for synthesizing conformal and functional polymer thin films on a variety of substrates. This thesis emphasizes the development of tools to further ...

Petruczok, Christy D. (Christy Danielle)

2014-01-01T23:59:59.000Z

353

Hyperfine Studies of Lithium Vapor using Saturated Absorption Spectroscopy  

E-Print Network (OSTI)

the frequency of a laser with respect to an atomic spectral feature.[20] As such, saturated absorptionHyperfine Studies of Lithium Vapor using Saturated Absorption Spectroscopy? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 3.3 Broadening Mechanisms . . . . . . . . . . . . . . . . . . . . . 15 3.4 Saturated Absorption

Cronin, Alex D.

354

All graphene electromechanical switch fabricated by chemical vapor deposition  

E-Print Network (OSTI)

We demonstrate an electromechanical switch comprising two polycrystalline graphene films; each deposited using ambient pressure chemical vapor deposition. The top film is pulled into electrical contact with the bottom film ...

Milaninia, Kaveh M.

355

Systems and methods for generation of hydrogen peroxide vapor  

DOE Patents (OSTI)

A system according to one embodiment includes a moisture trap for drying air; at least one of a first container and a second container; and a mechanism for at least one of: bubbling dried air from the moisture trap through a hydrogen peroxide solution in the first container for producing a hydrogen peroxide vapor, and passing dried air from the moisture trap into a headspace above a hydrogen peroxide solution in the second container for producing a hydrogen peroxide vapor. A method according one embodiment includes at least one of bubbling dried air through a hydrogen peroxide solution in a container for producing a first hydrogen peroxide vapor, and passing dried air from the moisture trap into a headspace above the hydrogen peroxide solution in a container for producing a second hydrogen peroxide vapor. Additional systems and methods are also presented.

Love, Adam H; Eckels, Joel Del; Vu, Alexander K; Alcaraz, Armando; Reynolds, John G

2014-12-02T23:59:59.000Z

356

Optical Precursors in Rubidium Vapor and Their Relation to Superradiance  

E-Print Network (OSTI)

Optical precursor is the sharp optical pulse front that does not show delay in absorptive media. In this thesis, optical precursor behavior in rubidium (Rb) vapor was investigated in the picoseconds regime. An amplified femtosecond laser was shaped...

Yang, Wenlong

2012-10-19T23:59:59.000Z

357

Photocoupling of Methane in Water Vapor to Saturated Hydrocarbons  

Science Journals Connector (OSTI)

Methane can be converted into alkanes (from C2 to C6) continuously by ultraviolet (185 nm) irradiation in the presence of water vapor. The products from this reaction are alkanes, which is different from the comp...

JunePyo Oh; Taketoshi Matsumoto; Junji Nakamura

2008-08-01T23:59:59.000Z

358

Mercury Vapor At Kawaihae Area (Thomas, 1986) | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor At Kawaihae Area (Thomas, 1986) Mercury Vapor At Kawaihae Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Kawaihae Area (Thomas, 1986) Exploration Activity Details Location Kawaihae Area Exploration Technique Mercury Vapor Activity Date Usefulness not useful DOE-funding Unknown Notes The soil geochemistry yielded quite complex patterns of mercury concentrations and radonemanation rates within the survey area (Cox and Cuff, 1981c). Mercury concentrations (Fig. 38) showed a general minimum along the Kawaihae-Waimea roads and a broad trend of increasing mercury concentrations toward both the north and south. There is no correlation apparent between the mercury patterns and either the resistivity sounding data or the surface geology in the area. The radon emanometry data (Fig.

359

Mercury Vapor At Lualualei Valley Area (Thomas, 1986) | Open Energy  

Open Energy Info (EERE)

Mercury Vapor At Lualualei Valley Area (Thomas, 1986) Mercury Vapor At Lualualei Valley Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Lualualei Valley Area (Thomas, 1986) Exploration Activity Details Location Lualualei Valley Area Exploration Technique Mercury Vapor Activity Date Usefulness useful DOE-funding Unknown Notes Soil mercury and radon emanation surveys were performed over much of the accessible surface of Lualualei Valley (Cox and Thomas, 1979). The results of these surveys (Figs 7 and 8) delineated several areas in which soil mercury concentrations or radon emanation rates were substantially above normal background values. Some of these areas were apparently coincident with the mapped fracture systems associated with the caldera boundaries.

360

Data:99932d14-ff6b-456d-bcb8-d5c0d20372d1 | Open Energy Information  

Open Energy Info (EERE)

32d14-ff6b-456d-bcb8-d5c0d20372d1 32d14-ff6b-456d-bcb8-d5c0d20372d1 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Sulphur Springs Valley E C Inc Effective date: 2013/03/18 End date if known: Rate name: Security Lighting: 175 Watt MVL on existing pole Sector: Lighting Description: Applies only to lights presently installed. No additional Mercury Vapor security lights shall be installed. As ordinary replacement of Mercury Vapor fixtures is required, they shall be replaced with an appropriate lighting fixture. Source or reference: http://www.ssvec.org/wp-content/uploads/downloads/2013/03/SSVEC-Rates-03.18.13.pdf

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Advanced Chemical Heat Pumps Using Liquid-Vapor Reactions  

E-Print Network (OSTI)

ically feasible systems have significant potential advantage over conventional tech nology. An electric drive reactive heat pump can use smaller heat exchangers and compressor than a vapor-compression machine, and have more flexible operating... are discussed, and performance is bounded. A discussion on liquid-vapor equilibria is included as introduction to the systems I- considered. The electric drive heat pump and TA are promising systems; the TA has potential for higher COP than absorption...

Kirol, L.

362

D/sup -/ production by charge transfer in metal vapors  

SciTech Connect

Fast D/sup -/ ions can be produced from D/sup +/ by multiple charge-transfer collisions in a metal-vapor target. Experimental cross sections and thick-target D/sup -/ yields are presented and discussed. The high D/sup -/ yield experimentally observed from charge transfer in cesium vapor is consistent with recent low-energy cross-section calculations and measurements.

Schlachter, A.S.

1980-10-01T23:59:59.000Z

363

Injection locked oscillator system for pulsed metal vapor lasers  

DOE Patents (OSTI)

An injection locked oscillator system for pulsed metal vapor lasers is disclosed. The invention includes the combination of a seeding oscillator with an injection locked oscillator (ILO) for improving the quality, particularly the intensity, of an output laser beam pulse. The present invention includes means for matching the first seeder laser pulses from the seeding oscillator to second laser pulses of a metal vapor laser to improve the quality, and particularly the intensity, of the output laser beam pulse.

Warner, Bruce E. (Livermore, CA); Ault, Earl R. (Dublin, CA)

1988-01-01T23:59:59.000Z

364

Tank 241-S-102 headspace gas and vapor characterization results for samples collected in March 1995  

SciTech Connect

Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

Huckaby, J.L. [Pacific Northwest Lab., Richland, WA (United States); Bratzel, D.R. [Westinghouse Hanford Co., Richland, WA (United States)

1995-09-26T23:59:59.000Z

365

investigating the source, transport, and isotope fractionation of water vapor in the atmospheric boundary layer  

E-Print Network (OSTI)

investigating the source, transport, and isotope fractionation of water vapor in the atmospheric cospectral similarity for temperature and water vapor isotope fluxes. mixing ratio generator Routine field use in water vapor isotope research. The unit generates a stable water vapor mixing ratio by measuring

Minnesota, University of

366

Calculating the vapor pressure of water from the second law of thermodynamics  

Science Journals Connector (OSTI)

Calculating the vapor pressure of water from the second law of thermodynamics ... Thermodynamics ...

M. H. Everdell

1969-01-01T23:59:59.000Z

367

The growth of vapor bubble and relaxation between two-phase bubble flow  

Science Journals Connector (OSTI)

This paper presents the behavior of the bubble growth and relaxation between vapor and superheated...

S. Mohammadein; Rama Subba Reddy Gorla

2003-01-01T23:59:59.000Z

368

Tank Vapor Characterization Project: Annual status report for FY 1996  

SciTech Connect

In Fiscal Year 1996, staff at the Vapor Analytical Laboratory at Pacific Northwest National Laboratory performed work in support of characterizing the vapor composition of the headspaces of radioactive waste tanks at the Hanford Site. Work performed included support for technical issues and sampling methodologies, upgrades for analytical equipment, analytical method development, preparation of unexposed samples, analyses of tank headspaces samples, preparation of data reports, and operation of the tank vapor database. Progress made in FY 1996 included completion and issuance of 50 analytical data reports. A sampling system comparison study was initiated and completed during the fiscal year. The comparison study involved the vapor sampling system (VSS), a truck-based system, and the in situ vapor sampling system (ISVS), a cart-based system. Samples collected during the study were characterized for inorganic, permanent gases, total non-methane organic compounds and organic speciation by SUMMA{trademark} and TST methods. The study showed comparable sampling results between the systems resulting in the program switching from the VSS to the less expensive ISVS methodology in late May 1996. A temporal study was initiated in January 1996 in order to understand the influences seasonal temperatures changes have on the vapors in the headspace of Hanford waste tanks. A holding time study was initiated in the fourth quarter of FY 1996. Samples were collected from tank S-102 and rushed to the laboratory for time zero analysis. Additional samples will be analyzed at 1, 2, 4, 8, 16, and 32 weeks.

Silvers, K.L.; Fruchter, J.S.; Huckaby, J.L.; Almeida, T.L.; Evans, J.C. Jr.; Pool, K.H.; Simonen, C.A.; Thornton, B.M.

1997-01-01T23:59:59.000Z

369

Mobile lighting apparatus  

DOE Patents (OSTI)

A mobile lighting apparatus includes a portable frame such as a moveable trailer or skid having a light tower thereon. The light tower is moveable from a stowed position to a deployed position. A hydrogen-powered fuel cell is located on the portable frame to provide electrical power to an array of the energy efficient lights located on the light tower.

Roe, George Michael; Klebanoff, Leonard Elliott; Rea, Gerald W; Drake, Robert A; Johnson, Terry A; Wingert, Steven John; Damberger, Thomas A; Skradski, Thomas J; Radley, Christopher James; Oros, James M; Schuttinger, Paul G; Grupp, David J; Prey, Stephen Carl

2013-05-14T23:59:59.000Z

370

Light-emitting nanocrystalline silicon by low-pressure chemical-vapor deposition of disilane  

Science Journals Connector (OSTI)

Porous silicon is an attractive material for silicon optoelectronics. The great advantage of porous silicon lies on the simple way of production which makes silicon nanostructures easily available. After sever...

C. Manfredotti; F. Fizzotti; G. Amato

1996-10-01T23:59:59.000Z

371

Light Old and New  

Science Journals Connector (OSTI)

The Sun, Moon and stars have been our lights since the earliest times. We have learned ... have much more recently filled our homes and streets with artificial lighting. We are, however, in danger of...natural lights

Bob Mizon

2002-01-01T23:59:59.000Z

372

Specific light in sculpture  

E-Print Network (OSTI)

Specific light is defined as light from artificial or altered natural sources. The use and manipulation of light in three dimensional sculptural work is discussed in an historic and contemporary context. The author's work ...

Powell, John William

1989-01-01T23:59:59.000Z

373

Natural lighting and skylights  

E-Print Network (OSTI)

There are many physiological and psychological factors which enter into the proper design of space for human occupancy. One of these elements is light. Both natural light and manufactured light are basic tools with which any designer must work...

Evans, Benjamin Hampton

1961-01-01T23:59:59.000Z

374

Parametric light generation  

Science Journals Connector (OSTI)

...potential to deliver coherent light with high spectral purity...universal constants such as the speed of light. Single- frequency CW...assessment of optical switching speeds in telecommunication technology...A (2003) Parametric light generation 2749 ment of...

2003-01-01T23:59:59.000Z

375

Data:86080fd2-d7f0-470b-8485-ac01338b1d2d | Open Energy Information  

Open Energy Info (EERE)

0fd2-d7f0-470b-8485-ac01338b1d2d 0fd2-d7f0-470b-8485-ac01338b1d2d No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Piedmont Electric Member Corp Effective date: 2011/01/01 End date if known: Rate name: OUTDOOR LIGHTING SERVICE 175 Watt Mercury Vapor Lamp Sector: Lighting Description: 1. The Cooperative shall furnish and install a wooden pole if required for the outdoor light, within 150 feet of existing secondary circuits. If an additional wood pole is required, other than for mounting the lighting fixture, there will be a contribution-in-aid of construction of $125.00 per pole. The contribution-in-aid of construction for the decorative post top fixture on the decorative fluted fiberglass pole with a twelve (12) foot mounting height will be $1,125.00. 2.The charge for the purchased power related costs shall be 3.904¢ times the estimated average monthly kWh usage. 3. Consumer requested conversion of an existing, properly operating Security light fixture will require the following one time service charge(s): Conversion of fixture on same pole, same location: $ 36.00 Conversion of fixture requiring removal of a pole: $36.00

376

Apparatus for isotopic alteration of mercury vapor  

DOE Patents (OSTI)

An apparatus for enriching the isotopic Hg content of mercury is provided. The apparatus includes a reactor, a low pressure electric discharge lamp containing a fill including mercury and an inert gas. A filter is arranged concentrically around the lamp. In a preferred embodiment, constant mercury pressure is maintained in the filter by means of a water-cooled tube that depends from it, the tube having a drop of mercury disposed in it. The reactor is arranged around the filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of a material which is transparent to ultraviolet light.

Grossman, Mark W. (Belmont, MA); George, William A. (Gloucester, MA); Marcucci, Rudolph V. (Danvers, MA)

1988-01-01T23:59:59.000Z

377

Lighting Group: Links  

NLE Websites -- All DOE Office Websites (Extended Search)

Links Links Links Organizations Illuminating Engineering Society of North America (IESNA) International Commission on Illumination (CIE) International Association of Lighting Designers (IALD) International Association of Energy-Efficient Lighting Lightfair International Energy Agency - Task 21: Daylight in Buildings: Design Tools and Performance Analysis International Energy Agency - Task 31: Daylighting Buildings in 21st Century National Association on Qualifications for the Lighting Professions (NCQLP) National Association of Independent Lighting Distributors (NAILD) International Association of Lighting Management Companies (NALMCO) Research Centers California Lighting Technology Center Lighting Research Center Lighting Research at Canada Institute for Research in Construction

378

Advanced Demand Responsive Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Demand Responsive Lighting Host: Francis Rubinstein Demand Response Research Center Technical Advisory Group Meeting August 31, 2007 10:30 AM - Noon Meeting Agenda * Introductions (10 minutes) * Main Presentation (~ 1 hour) * Questions, comments from panel (15 minutes) Project History * Lighting Scoping Study (completed January 2007) - Identified potential for energy and demand savings using demand responsive lighting systems - Importance of dimming - New wireless controls technologies * Advanced Demand Responsive Lighting (commenced March 2007) Objectives * Provide up-to-date information on the reliability, predictability of dimmable lighting as a demand resource under realistic operating load conditions * Identify potential negative impacts of DR lighting on lighting quality Potential of Demand Responsive Lighting Control

379

Modeling LED street lighting  

Science Journals Connector (OSTI)

LED luminaires may deliver precise illumination patterns to control light pollution, comfort, visibility, and light utilization efficiency. Here, we provide simple equations to...

Moreno, Ivan; Avendaño-Alejo, Maximino; Saucedo-A, Tonatiuh; Bugarin, Alejandra

2014-01-01T23:59:59.000Z

380

Lighting | Open Energy Information  

Open Energy Info (EERE)

TODO: Add description List of Lighting Incentives Retrieved from "http:en.openei.orgwindex.php?titleLighting&oldid267174" Category: Articles with outstanding TODO tasks...

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Light Duty Combustion Research: Advanced Light-Duty Combustion...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Light Duty Combustion Research: Advanced Light-Duty Combustion Experiments Light Duty Combustion Research: Advanced Light-Duty Combustion Experiments 2009 DOE Hydrogen Program and...

382

Oxidation of zirconium alloys in 2.5 kPa water vapor for tritium readiness.  

SciTech Connect

A more reactive liner material is needed for use as liner and cruciform material in tritium producing burnable absorber rods (TPBAR) in commercial light water nuclear reactors (CLWR). The function of these components is to convert any water that is released from the Li-6 enriched lithium aluminate breeder material to oxide and hydrogen that can be gettered, thus minimizing the permeation of tritium into the reactor coolant. Fourteen zirconium alloys were exposed to 2.5 kPa water vapor in a helium stream at 300 C over a period of up to 35 days. Experimental alloys with aluminum, yttrium, vanadium, titanium, and scandium, some of which also included ternaries with nickel, were included along with a high nitrogen impurity alloy and the commercial alloy Zircaloy-2. They displayed a reactivity range of almost 500, with Zircaloy-2 being the least reactive.

Mills, Bernice E.

2007-11-01T23:59:59.000Z

383

Mercury Source Zone Identification using Soil Vapor Sampling and Analysis  

SciTech Connect

Development and demonstration of reliable measurement techniqes that can detect and help quantify the nature and extent of elemental mercury (Hg(0)) in the subsurface are needed to reduce certainties in the decision making process and increase the effectiveness of remedial actions. We conducted field tests at the Y-12 National Security Complex (NSC) in Oak Ridge, TN, to determine if sampling and analysis of Hg(0) vapors in the shallow subsurface (<0.3 m depth) can be used to as an indicator of the location and extent of Hg(0) releases in the subsurface. We constructed a rigid PVC pushprobe assembly, which was driven into the ground. Soil gas samples were collected through a sealed inner tube of the assembly and analyzed immediately in the field with a Lumex and/or Jerome Hg(0) analyzer. Time-series sampling showed that Hg vapor concentrations were fairly stable over time suggesting that the vapor phase Hg(0) was not being depleted and that sampling results were not dependent on the soil gas purge volume. Hg(0) vapor data collected at over 200 pushprobe locations at 3 different release sites correlated well to areas of known Hg(0) contamination. Vertical profiling of Hg(0) vapor concentrations conducted at 2 locations provided information on the vertical distribution of Hg(0) contamination in the subsurface. We concluded from our studies that soil gas sampling and analysis can be conducted rapidly and inexpensively at a large scale to help identify areas contaminated with Hg(0).

Watson, David B [ORNL] [ORNL; Miller, Carrie L [ORNL] [ORNL; Lester, Brian P [ORNL] [ORNL; Lowe, Kenneth Alan [ORNL] [ORNL; Southworth, George R [ORNL] [ORNL; Bogle, Mary Anna [ORNL] [ORNL; Liang, Liyuan [ORNL] [ORNL; Pierce, Eric M [ORNL] [ORNL

2014-01-01T23:59:59.000Z

384

Vapor etching of nuclear tracks in dielectric materials  

DOE Patents (OSTI)

A process involving vapor etching of nuclear tracks in dielectric materials for creating high aspect ratio (i.e., length much greater than diameter), isolated cylindrical holes in dielectric materials that have been exposed to high-energy atomic particles. The process includes cleaning the surface of the tracked material and exposing the cleaned surface to a vapor of a suitable etchant. Independent control of the temperatures of the vapor and the tracked materials provide the means to vary separately the etch rates for the latent track region and the non-tracked material. As a rule, the tracked regions etch at a greater rate than the non-tracked regions. In addition, the vapor-etched holes can be enlarged and smoothed by subsequent dipping in a liquid etchant. The 20-1000 nm diameter holes resulting from the vapor etching process can be useful as molds for electroplating nanometer-sized filaments, etching gate cavities for deposition of nano-cones, developing high-aspect ratio holes in trackable resists, and as filters for a variety of molecular-sized particles in virtually any liquid or gas by selecting the dielectric material that is compatible with the liquid or gas of interest.

Musket, Ronald G. (Danville, CA); Porter, John D. (Berkeley, CA); Yoshiyama, James M. (Fremont, CA); Contolini, Robert J. (Lake Oswego, OR)

2000-01-01T23:59:59.000Z

385

PHASE BEHAVIOR OF LIGHT GASES IN HYDROCARBON AND AQUEOUS SOLVENTS  

SciTech Connect

Under previous support from the Department of Energy, an experimental facility has been established and operated to measure valuable vapor-liquid equilibrium data for systems of interest in the production and processing of coal fluids. To facilitate the development and testing of models for prediction of the phase behavior for such systems, we have acquired substantial amounts of data on the equilibrium phase compositions for binary mixtures of heavy hydrocarbon solvents with a variety of supercritical solutes, including hydrogen, methane, ethane, carbon monoxide, and carbon dioxide. The present project focuses on measuring the phase behavior of light gases and water in Fischer-Tropsch (F-T) type solvents at conditions encountered in indirect liquefaction processes and evaluating and developing theoretically-based correlating frameworks to predict the phase behavior of such systems. Specific goals of the proposed work include (a) developing a state-of-the-art experimental facility to permit highly accurate measurements of equilibrium phase compositions (solubilities) of challenging F-T systems, (b) measuring these properties for systematically-selected binary, ternary and molten F-T wax mixtures to provide critically needed input data for correlation development, (c) developing and testing models suitable for describing the phase behavior of such mixtures, and (d) presenting the modeling results in generalized, practical formats suitable for use in process engineering calculations. During the present period, the Park-Gasem-Robinson (PGR) equation of state (EOS) has been modified to improve its volumetric and equilibrium predictions. Specifically, the attractive term of the PGR equation was modified to enhance the flexibility of the model, and a new expression was developed for the temperature dependence of the attractive term in this segment-segment interaction model. The predictive capability of the modified PGR EOS for vapor pressure, and saturated liquid and vapor densities was evaluated for selected normal paraffins, normal alkenes, cyclo-paraffins, light aromatics, argon, carbon dioxide and water. The generalized EOS constants and substance-specific characteristic parameters in the modified PGR EOS were obtained from the pure component vapor pressures, and saturated liquid and vapor molar volumes. The calculated phase properties were compared to those of the Peng-Robinson (PR), the simplified-perturbed-hard-chain theory (SPHCT) and the original PGR equations. Generally, the performance of the proposed EOS was better than the PR, SPHCT and original PGR equations in predicting the pure fluid properties (%AAD of 1.3, 2.8 and 3.7 for vapor pressure, saturated liquid and vapor densities, respectively).

KHALED A.M. GASEM; ROBERT L. ROBINSON, JR.

1998-08-31T23:59:59.000Z

386

Filter for isotopic alteration of mercury vapor  

DOE Patents (OSTI)

A filter for enriching the .sup.196 Hg content of mercury, including a reactor, a low pressure electric discharge lamp containing a fill of mercury and an inert gas. A filter is arranged concentrically around the lamp. The reactor is arranged around said filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of quartz, and are transparent to ultraviolet light. The .sup.196 Hg concentration in the mercury fill is less than that which is present in naturally occurring mercury, that is less than about 0.146 atomic weight percent. Hydrogen is also included in the fill and serves as a quenching gas in the filter, the hydrogen also serving to prevent disposition of a dark coating on the interior of the filter.

Grossman, Mark W. (Belmont, MA); George, William A. (Gloucestor, MA)

1989-01-01T23:59:59.000Z

387

Filter for isotopic alteration of mercury vapor  

DOE Patents (OSTI)

A filter is described for enriching the [sup 196]Hg content of mercury, including a reactor, a low pressure electric discharge lamp containing a fill of mercury and an inert gas. A filter is arranged concentrically around the lamp. The reactor is arranged around said filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of quartz, and are transparent to ultraviolet light. The [sup 196]Hg concentration in the mercury fill is less than that which is present in naturally occurring mercury, that is, less than about 0.146 atomic weight percent. Hydrogen is also included in the fill and serves as a quenching gas in the filter, the hydrogen also serving to prevent disposition of a dark coating on the interior of the filter. 9 figs.

Grossman, M.W.; George, W.A.

1989-06-13T23:59:59.000Z

388

Validation of TES Temperature and Water Vapor Retrievals with ARM  

NLE Websites -- All DOE Office Websites (Extended Search)

Validation of TES Temperature and Water Vapor Retrievals with ARM Validation of TES Temperature and Water Vapor Retrievals with ARM Observations Cady-Pereira, Karen Atmospheric and Environmental Research, Inc. Shephard, Mark Atmospheric and Environmental Research, Inc. Clough, Shepard Atmospheric and Environmental Research Mlawer, Eli Atmospheric & Environmental Research, Inc. Turner, David University of Wisconsin-Madison Category: Atmospheric State and Surface The primary objective of the TES (Tropospheric Emission Spectrometer) instrument on the Aura spacecraft is the retrieval of trace gases, especially water vapor and ozone. The TES retrievals extremely useful for global monitoring of the atmospheric state, but they must be validated. The ARM sites are well instrumented and provide continuous measurements, which

389

VAPORIZATION OF TUNGSTEN-METAL IN STEAM AT HIGH TEMPERATURES.  

SciTech Connect

The vaporization of tungsten from the APT spallation target dominates the radiological source term for unmitigated target overheating accidents. Chemical reactions of tungsten with steam which persist to tungsten temperatures as low as 800 C result in the formation of a hydrated tungsten-oxide which has a high vapor pressure and is readily convected in a flowing atmosphere. This low-temperature vaporization reaction essentially removes the oxide film that forms on the tungsten-metal surface as soon as it forms, leaving behind a fresh metallic surface for continued oxidation and vaporization. Experiments were conducted to measure the oxidative vaporization rates of tungsten in steam as part of the effort to quantify the MT radiological source term for severe target accidents. Tests were conducted with tungsten rods (1/8 inch diameter, six inches long) heated to temperatures from approximately 700 C to 1350 C in flowing steam which was superheated to 140 C. A total of 19 experiments was conducted. Fifteen tests were conducted by RF induction heating of single tungsten rods held vertical in a quartz glass retort. Four tests were conducted in a vertically-mounted tube furnace for the low temperature range of the test series. The aerosol which was generated and transported downstream from the tungsten rods was collected by passing the discharged steam through a condenser. This procedure insured total collection of the steam along with the aerosol from the vaporization of the rods. The results of these experiments revealed a threshold temperature for tungsten vaporization in steam. For the two tests at the lowest temperatures which were tested, approximately 700 C, the tungsten rods were observed to oxidize without vaporization. The remainder of the tests was conducted over the temperature range of 800 C to 1350 C. In these tests, the rods were found to have lost weight due to vaporization of the tungsten and the missing weight was collected in the downstream condensate system. The aerosol formed a fine white smoke of tungsten-oxide which was visible to the eye as it condensed in the laminar boundary layer of steam which flowed along the surface of the rod. The aerosol continued to flow as a smoke tube downstream of the rod, flowing coaxially along the centerline axis of the quartz glass tube and depositing by impaction along the outside of a bend and at sudden area contractions in the piping. The vaporization rate data from the 17 experiments which exceeded the vaporization threshold temperature are shown in Figure 5 in the form of vaporization rates (g/cm{sup 2} s) vs. inverse temperature (K{sup {minus}1}). Two correlations to the present data are presented and compared to a published correlation by Kilpatrick and Lott. The differences are discussed.

GREENE,G.A.; FINFROCK,C.C.

2000-10-01T23:59:59.000Z

390

Phase effects for electrons in liquid water and water vapor  

SciTech Connect

The objective of these studies is to compare transport, energy loss, and other phenomena for electrons in water in the liquid and vapor phases. Understanding the differences and similarities is an interesting physics problem in its own right. It is also important for applying the relatively large body of experimental data available for the vapor to the liquid, which is of greater relevance in radiobiology. This paper presents a summary of results from a series of collaborative studies carried out by the authors at Oak Ridge National Laboratory (ORNL) and the Gesellschaft fuer Strahlen- und Umweltforschung (GSF). 14 figs.

Turner, J.E.; Paretzke, H.G.; Wright, H.A.; Hamm, R.N.; Ritchie, R.H.

1988-01-01T23:59:59.000Z

391

Growth of manganese filled carbon nanofibers in the vapor phase  

Science Journals Connector (OSTI)

We report the vapor phase growth of partially filled graphitic fibers, 20-30 nm in diameter and up to a micron in length, during a manganese catalyzed carbon electric arc discharge. The fiber morphology resembles that of catalytic chemical vapor deposited carbon filaments but the inside hollow contains intermittent precipitates and continuous filling of Mn that at times occupy >50% of fiber lengths. Transmission electron microscopy and electron energy loss line spectra show that the fillings form as solid cores and may correspond to pure metal.

P. M. Ajayan; C. Colliex; J. M. Lambert; P. Bernier; L. Barbedette; M. Tence; O. Stephan

1994-03-14T23:59:59.000Z

392

The development of a passive dosimeter for airborne aniline vapors  

E-Print Network (OSTI)

passive sampl1ng dosimeter was designed to measure concen- trat1ons of aniline vapor in air. Diffus1on tubes of 1. 5, 3. 0 and 4. 5 cm lengths were tested under controlled conditions of relative humid1ty, air temperature and vapor concentrations. A... of Measured vs Calculated Concentrations APPENDIX D-Student-t Test on Slopes of Measured vs Calculated Data . APPENDIX E-Statistical Analysis of Four Hour Time- Weighted Average Study on 3. 0 cm Dosimeter VITA ~pa e 42 45 48 59 62 63 65 70 73...

Campbell, James Evan

1977-01-01T23:59:59.000Z

393

Solid–Liquid–Vapor Equilibrium Models for Cryogenic Biogas Upgrading  

Science Journals Connector (OSTI)

In cryogenic upgrading processes involving dry ice formation, accurate predictions of solid–liquid, solid–vapor, and solid–liquid–vapor equilibria are fundamental for a correct design of the heat exchanger surface in order to achieve the desired biomethane purity. ... Moreover, the liquefied biogas production process, particularly interesting for cryogenic upgrading processes due to the low temperature of the obtained biomethane, requires an accurate knowledge of carbon dioxide solubility in liquid methane to avoid solid deposition. ... For some applications demanding a high energy content gas, namely vehicle fuels and injection in the natural gas grid, the biogas has to be upgraded into biomethane. ...

Mauro Riva; Marco Campestrini; Joseph Toubassy; Denis Clodic; Paolo Stringari

2014-10-13T23:59:59.000Z

394

Spectrally Enhanced Lighting  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

November 2007 November 2007 AfterImage + s p a c e 1 Spectrally Enhanced Lighting Spectrally Enhanced Lighting Brian Liebel, PE, LC Brian Liebel, PE, LC November 29, 2007 November 29, 2007 Federal Utilities Partnership Working Group Federal Utilities Partnership Working Group November 29, 2007 November 29, 2007 29 November 2007 AfterImage + s p a c e 2 Spectrally Enhanced Lighting Spectrally Enhanced Lighting Spectrally Enhanced Lighting Spectrally Enhanced Lighting This is not a technology; just a This is not a technology; just a different way to quantify light based on different way to quantify light based on well established scientific findings well established scientific findings Can be used in conjunction with ANY Can be used in conjunction with ANY type of lighting design to gain

395

Data:Fd4a1d85-7f5c-46aa-90b2-bccb09df9df3 | Open Energy Information  

Open Energy Info (EERE)

-7f5c-46aa-90b2-bccb09df9df3 -7f5c-46aa-90b2-bccb09df9df3 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Crisp County Power Comm Effective date: 2012/01/01 End date if known: Rate name: Rental Light Service-Parking Lot Shoebox- One Fixture (350/400 W MH/HPS) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide. Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh):

396

Data:7d6e144f-1ee4-4317-9d4d-5000bbb042b0 | Open Energy Information  

Open Energy Info (EERE)

4f-1ee4-4317-9d4d-5000bbb042b0 4f-1ee4-4317-9d4d-5000bbb042b0 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Crisp County Power Comm Effective date: 2012/01/01 End date if known: Rate name: Rental Light Service-Parking Lot Shoebox- Two Fixture (350/400 W MH/HPS) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide. Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh):

397

Data:Ce257723-a06c-4647-a520-102fafcf2c22 | Open Energy Information  

Open Energy Info (EERE)

Ce257723-a06c-4647-a520-102fafcf2c22 Ce257723-a06c-4647-a520-102fafcf2c22 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Crisp County Power Comm Effective date: 2012/01/01 End date if known: Rate name: Rental Light Service-Post Top Fixtures- (Traditional MH 150/175W) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide. Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh):

398

Data:957488aa-519a-412c-aab9-de57c307d0ba | Open Energy Information  

Open Energy Info (EERE)

aa-519a-412c-aab9-de57c307d0ba aa-519a-412c-aab9-de57c307d0ba No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Crisp County Power Comm Effective date: 2012/01/01 End date if known: Rate name: Rental Light Service-Post Top Fixtures- (Galleria HPS 150W) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide. Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months):

399

Data:1ed95e55-77c3-4ba5-a97f-2ae396b39928 | Open Energy Information  

Open Energy Info (EERE)

5-77c3-4ba5-a97f-2ae396b39928 5-77c3-4ba5-a97f-2ae396b39928 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Crisp County Power Comm Effective date: 2012/01/01 End date if known: Rate name: Rental Light Service-Post Top Fixtures- (Torch MH 250W) Sector: Lighting Description: Applicable only to outdoor lighting by ballast operated vapor lamp fixtures, either Mercury Vapor, Pressure Sodium, or Metal Halide. Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months):

400

UNCORRECTEDPROOF 2 Vaporization, fusion and sublimation enthalpies of the  

E-Print Network (OSTI)

UNCORRECTEDPROOF 2 Vaporization, fusion and sublimation enthalpies of the 3 dicarboxylic acids from of Chemistry and Biochemistry, University of Missouri-St. Louis, 8001 Natural Bridge, St. Louis, MO 63121, USA observed previously in the sublimation enthalpies of these compounds. The results are dis- 16 cussed

Chickos, James S.

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Vapor-side corrosion in thermal desalination plants  

SciTech Connect

This article reports the results of vapor-size corrosion monitoring studies carried out in multistage flash (MSF) desal unit No. 100 of Al-Khafji power and Desalination Plant in Saudi Arabia. Corrosion behavior of 70/30 Cu-Ni alloy, carbon steel (CS), and type 316L stainless steel (SS) was studied in vents and in the vapor size of distillers for 2,000, 4,000, and 9,000 h. Analyses of the experimental data indicated that in addition to O{sub 2}, S-containing compounds evolved during flashing of seawater reacted more with Cu-Ni alloy than with CS and type 316L SS. Explanations for comparatively higher corrosion of alloys exposed to the vapors of the first three (1 to 3) and middle (11 to 13) stages of the MSF plant are given with experimental results. Type 316L SS was found to be the alloy most resistant to vapor-side corrosion in all stages of distillers.

Asrar, N.; Malik, A.U.; Ahmed, S. [Saline Water Conversion Corp. (Saudi Arabia); Al-Khalidi, M.; Al-Moaili, K. [Al-Khafji Desalination Plant (Saudi Arabia)

1999-04-01T23:59:59.000Z

402

Fatigue Resistance of Asphalt Mixtures Affected by Water Vapor Movement  

E-Print Network (OSTI)

This dissertation has two key objectives: the first objective is to develop a method of predicting and quantifying the amount of water that can enter into a pavement system by vapor transport; the second objective is to identify to which extent...

Tong, Yunwei

2013-11-08T23:59:59.000Z

403

The chemical vapor deposition of zirconium carbide onto ceramic substrates  

SciTech Connect

Zirconium carbide is an attractive ceramic material due to its unique properties such as high melting point, good thermal conductivity, and chemical resistance. The controlled preparation of zirconium carbide films of superstoichiometric, stoichiometric, and substoichiometric compositions has been achieved utilizing zirconium tetrachloride and methane precursor gases in an atmospheric pressure high temperature chemical vapor deposition system.

Glass, John A, Jr.; Palmisiano, Nick, Jr.; Welsh, R. Edward

1999-07-01T23:59:59.000Z

404

A transient model for a cesium vapor thermionic converter. [Cs  

SciTech Connect

This paper presents an analytical model for simulating the transient and steady-state operation of cesium vapor thermionic converters. A parametric analysis is performed to assess the transient response of the converter to changes in fission power and width of interelectrode gap. The model optimizes the converter performance for maximum electric power to the load.(AIP)

El-Genk, M.S.; Murray, C.S.; Chaudhuri, S. (Institute for Space Nuclear Power Studies, Department of Chemical and Nuclear Engineering, The University of New Mexico, Albuquerque, New Mexico (USA))

1991-01-10T23:59:59.000Z

405

Experimental Study of Water Vapor Adsorption on Geothermal  

E-Print Network (OSTI)

Geothermal Program under Department of Energy Grant No. DE-FG07-90IDI2934,and by the Department of PetroleumSGP-TR-148 Experimental Study of Water Vapor Adsorption on Geothermal Reservoir Rocks Shubo Shang Engineering, Stanford University Stanford Geothermal Program Interdisciplinary Research in Engineering

Stanford University

406

CVD CNT CNT (Vapor-grown carbon fiber, VGCF)  

E-Print Network (OSTI)

CNT CNT CVD CNT CNT (Vapor-grown carbon fiber, VGCF) 10001300 CNT CVD Smalley CO 24 CCVD 1 #12; 27 mm 3% 200 sccm 800 10 10 Torr 300 sccm Ethanol tank Hot bath boat Ar/H2 Ar or Ethanol tank Hot bath Ethanol tank Hot bath Pressure gauge Maindraintube Subdraintube

Maruyama, Shigeo

407

Method for removing metal vapor from gas streams  

DOE Patents (OSTI)

A process for cleaning an inert gas contaminated with a metallic vapor, such as cadmium, involves withdrawing gas containing the metallic contaminant from a gas atmosphere of high purity argon; passing the gas containing the metallic contaminant to a mass transfer unit having a plurality of hot gas channels separated by a plurality of coolant gas channels; cooling the contaminated gas as it flows upward through the mass transfer unit to cause contaminated gas vapor to condense on the gas channel walls; regenerating the gas channels of the mass transfer unit; and, returning the cleaned gas to the gas atmosphere of high purity argon. The condensing of the contaminant-containing vapor occurs while suppressing contaminant particulate formation, and is promoted by providing a sufficient amount of surface area in the mass transfer unit to cause the vapor to condense and relieve supersaturation buildup such that contaminant particulates are not formed. Condensation of the contaminant is prevented on supply and return lines in which the contaminant containing gas is withdrawn and returned from and to the electrorefiner and mass transfer unit by heating and insulating the supply and return lines.

Ahluwalia, R. K. (6440 Hillcrest Dr., Burr Ridge, IL 60521); Im, K. H. (925 Lehigh Cir., Naperville, IL 60565)

1996-01-01T23:59:59.000Z

408

Sorption and Diffusion of Organic Vapors in Two Fluoroelastomers  

E-Print Network (OSTI)

Sorption and Diffusion of Organic Vapors in Two Fluoroelastomers PING WANG,* NATHANIEL S. SCHNEIDER of II in polar liquids: over 100% (wt/wt) in two ketones and a phosphate ester. Sorption isotherms deter determined from sorption kinetics, corrected for nonisothermal effects, and converted to solvent self

Wang, Ping

409

High-resolution terahertz atmospheric water vapor continuum measurements  

E-Print Network (OSTI)

High-resolution terahertz atmospheric water vapor continuum measurements David M. Slocum,* Thomas M such as pollution monitoring and the detection of energetic chemicals using remote sensing over long path lengths through the atmosphere. Although there has been much attention to atmospheric effects over narrow

Massachusetts at Lowell, University of

410

Method and apparatus to measure vapor pressure in a flow system  

DOE Patents (OSTI)

The present invention is directed to a method for determining, by a condensation method, the vapor pressure of a material with a known vapor pressure versus temperature characteristic, in a flow system particularly in a mercury isotope enrichment process.

Grossman, Mark W. (Belmont, MA); Biblarz, Oscar (Swampscott, MA)

1991-01-01T23:59:59.000Z

411

Tropical Water Vapor and Cloud Feedbacks in Climate Models: A Further Assessment Using Coupled Simulations  

Science Journals Connector (OSTI)

By comparing the response of clouds and water vapor to ENSO forcing in nature with that in Atmospheric Model Intercomparison Project (AMIP) simulations by some leading climate models, an earlier evaluation of tropical cloud and water vapor ...

De-Zheng Sun; Yongqiang Yu; Tao Zhang

2009-03-01T23:59:59.000Z

412

Metalorganic chemical vapor deposition of carbon-free ZnO using...  

NLE Websites -- All DOE Office Websites (Extended Search)

Metalorganic chemical vapor deposition of carbon-free ZnO using the bis(2,2,6,6-tetramethyl-3,5-heptanedionato)zinc precursor. Metalorganic chemical vapor deposition of carbon-free...

413

Economic and Technical Tradeoffs Between Open and Closed Cycle Vapor Compression Evaporators  

E-Print Network (OSTI)

and solute. Evaporation tends to be a very energy intensive process. Approximately 1000 BTUs of energy are required to vaporize one pound of water. Many techniques have been developed to reuse energy Within an evaporation system so as to vaporize... Recompression A schematic of an open cycle vapor recompression evaporator is shown in Figure 2. This method uses the vapor in an open cycle for both heating and cooling. Rather than being condensed after the last effect, steam is compressed to a slightly...

Timm, M. L.

414

Solid-State Lighting: Solid-State Lighting  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solid-State Lighting Search Solid-State Lighting Search Search Help Solid-State Lighting HOME ABOUT THE PROGRAM R&D PROJECTS MARKET-BASED PROGRAMS SSL BASICS INFORMATION RESOURCES FINANCIAL OPPORTUNITIES EERE » Building Technologies Office » Solid-State Lighting Printable Version Share this resource Send a link to Solid-State Lighting: Solid-State Lighting to someone by E-mail Share Solid-State Lighting: Solid-State Lighting on Facebook Tweet about Solid-State Lighting: Solid-State Lighting on Twitter Bookmark Solid-State Lighting: Solid-State Lighting on Google Bookmark Solid-State Lighting: Solid-State Lighting on Delicious Rank Solid-State Lighting: Solid-State Lighting on Digg Find More places to share Solid-State Lighting: Solid-State Lighting on AddThis.com... Pause/Resume Photo of a large room with people standing around poster boards.

415

Lighting Group: Overview  

NLE Websites -- All DOE Office Websites (Extended Search)

Overview Overview Overview of the Lighting Research Group The Lighting Research Group at Lawrence Berkeley National Laboratory performs research aimed at improving the energy efficiency of lighting systems in buildings and homes, throughout the State of California and across the Nation. The goal is to reduce lighting energy consumption by 50% over twenty years by improving the efficiency of light sources, and controlling and delivering illumination so that it is available, where and when needed, and at the required intensity. Research in the Lighting Group falls into three main areas: Sources and Ballasts, Light Distribution Systems and Controls and Communications. Click on a link below for more information about each of these research areas. Sources and Ballasts investigates next generation light sources, such as

416

Smart street lighting management  

Science Journals Connector (OSTI)

In this work, we propose a new street lighting energy management system in order to reduce ... demand” meaning that energy, in this case light, is provided only when needed. In ... demand model, which in the case...

S. Pizzuti; M. Annunziato; F. Moretti

2013-08-01T23:59:59.000Z

417

Adaptive Street Lighting Controls  

Energy.gov (U.S. Department of Energy (DOE))

This two-part DOE Municipal Solid-State Street Lighting Consortium webinar focused on LED street lighting equipped with adaptive control components. In Part I, presenters Amy Olay of the City of...

418

Kyler Nelson Light Timer  

E-Print Network (OSTI)

designated by the user, the Arduino board will dim the light to save energy. The user designates the time instance, the light is dimmed using pulse width modulation (PWM) in the Arduino's pin number 11

Kachroo, Pushkin

419

Quantitative Analysis of Ternary Vapor Mixtures Using a Microcantilever-Based Electronic Nose  

SciTech Connect

The authors report the identification and quantification of the components of a ternary vapor mixture using a microcantilever-based electronic nose. An artificial neural network was used for pattern recognition. Dimethyl methyl phosphonate vapor in ppb concentrations and water and ethanol vapors in ppm concentrations were quantitatively identified either individually or in binary and ternary mixtures at varying concentrations.

Pinnaduwage, Lal A [ORNL; Zhao, Weichang [ORNL; Gehl, Anthony C [ORNL; Allman, Steve L [ORNL

2007-01-01T23:59:59.000Z

420

Sample Vapor Introduction Techniques for Use with Cryofocusing GC Inlet Systems  

Science Journals Connector (OSTI)

......the vapor generator was operated at atmospheric pressure for...condensed water. Other studies...Because the water vapor was...tail of the water peak. Thus...obtained from an atmospheric pressure source...the vapor generator over a 1......

Christine L. Rankin; Richard D. Sacks

1994-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Measurements of atmospheric water vapor above Mauna Kea using an infrared radiometer  

E-Print Network (OSTI)

Measurements of atmospheric water vapor above Mauna Kea using an infrared radiometer David A in atmospheric water vapor that distort the phase coherence of incoming celestial signals. The signal received water vapor, this paper presents results obtained with a second generation IRMA operating at the James

Naylor, David A.

422

Outdoor Lighting Resources  

Energy.gov (U.S. Department of Energy (DOE))

DOE offers a variety of resources to guide municipalities, utilities, and others in their evaluation of LED street lighting products.

423

Light emitting device comprising phosphorescent materials for white light generation  

DOE Patents (OSTI)

The present invention relates to phosphors for energy downconversion of high energy light to generate a broadband light spectrum, which emit light of different emission wavelengths.

Thompson, Mark E.; Dapkus, P. Daniel

2014-07-22T23:59:59.000Z

424

Resonant energy transfer in light harvesting and light emitting applications.  

E-Print Network (OSTI)

??The performance of light emitting and light harvesting devices is improved by utilising resonant energy transfer. In lighting applications, the emission energy of a semiconductor… (more)

Chanyawadee, Soontorn

2009-01-01T23:59:59.000Z

425

Solid-State Lighting: Solid-State Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting Lighting Printable Version Share this resource Send a link to Solid-State Lighting: Solid-State Lighting to someone by E-mail Share Solid-State Lighting: Solid-State Lighting on Facebook Tweet about Solid-State Lighting: Solid-State Lighting on Twitter Bookmark Solid-State Lighting: Solid-State Lighting on Google Bookmark Solid-State Lighting: Solid-State Lighting on Delicious Rank Solid-State Lighting: Solid-State Lighting on Digg Find More places to share Solid-State Lighting: Solid-State Lighting on AddThis.com... Pause/Resume Photo of a large room with people standing around poster boards. Register Now for DOE's 11th Annual SSL R&D Workshop January 28-30, join other SSL R&D professionals from industry, government, and academia to learn, share, and shape the future of lighting.

426

Solid-State Lighting: Solid-State Lighting Contacts  

NLE Websites -- All DOE Office Websites (Extended Search)

About the About the Program Printable Version Share this resource Send a link to Solid-State Lighting: Solid-State Lighting Contacts to someone by E-mail Share Solid-State Lighting: Solid-State Lighting Contacts on Facebook Tweet about Solid-State Lighting: Solid-State Lighting Contacts on Twitter Bookmark Solid-State Lighting: Solid-State Lighting Contacts on Google Bookmark Solid-State Lighting: Solid-State Lighting Contacts on Delicious Rank Solid-State Lighting: Solid-State Lighting Contacts on Digg Find More places to share Solid-State Lighting: Solid-State Lighting Contacts on AddThis.com... Contacts Partnerships Solid-State Lighting Contacts For information about Solid-State Lighting, contact James Brodrick Lighting Program Manager Building Technologies Office U.S. Department of Energy

427

Solid-State Lighting: Adaptive Street Lighting Controls  

NLE Websites -- All DOE Office Websites (Extended Search)

Adaptive Street Lighting Adaptive Street Lighting Controls to someone by E-mail Share Solid-State Lighting: Adaptive Street Lighting Controls on Facebook Tweet about Solid-State Lighting: Adaptive Street Lighting Controls on Twitter Bookmark Solid-State Lighting: Adaptive Street Lighting Controls on Google Bookmark Solid-State Lighting: Adaptive Street Lighting Controls on Delicious Rank Solid-State Lighting: Adaptive Street Lighting Controls on Digg Find More places to share Solid-State Lighting: Adaptive Street Lighting Controls on AddThis.com... Conferences & Meetings Presentations Publications Webcasts Videos Tools Adaptive Street Lighting Controls This two-part DOE Municipal Solid-State Street Lighting Consortium webinar focused on LED street lighting equipped with adaptive control components.

428

Control of light speed: From slow light to superluminal light  

E-Print Network (OSTI)

A scheme for controlling light speed from slower-than-c to faster-than-c in an atomic system is presented in this paper. The scheme is based on far detuning Raman effect. Two far detuning coupling fields with small frequency difference will produce two absorptive peaks for the probe field in a $\\Lambda$ structure, and an optical pump between the two ground states can change the absorptive peaks into enhanced peaks, which makes the normal dispersion between the two peaks change into anomalous dispersion, so the probe field can change from slow light to superluminal propagation.

Qun-Feng Chen; Yong-Sheng Zhang; Bao-Sen Shi; Guang-Can Guo

2008-07-01T23:59:59.000Z

429

Theory and Experiments Relating to the Striated Glow Discharge in Mercury Vapor  

Science Journals Connector (OSTI)

Theory of the glow discharge in a monatomic gas.—For the case of parallel plane electrodes with a hot cathode as source of electrons, the potential distribution and ion concentration in the Crookes dark space, negative glow, Faraday dark space and positive column are shown to be predictable from considerations of space charge and of ionization and excitation of the gas. While with weak currents there is a negative space charge throughout, sufficiently intense ionization is shown to lead to a cathode drop, followed by a region of reversed electric field in which positive ions and electrons both move toward the anode by diffusion, owing to their large concentration gradient. Still farther from the cathode the field changes to its normal direction and increases up to the positive column. In the positive column the field and concentration are uniform unless atoms excited by electron impacts in certain layers are prevented from diffusing between the layers, when striations may be obtained with periodic changes of field and of concentration. The cathode edge of each striation has a positive space charge. The theory of the arc discharge is essentially the same, the arc being simply the negative glow of the longer glow discharge.Glow discharge in mercury vapor.—Various predictions of the above theory were verified by experiments with Hg vapor in vacuum tubes provided with hot cathodes. (1) Potential distribution and ion concentration were investigated by Langmuir's modified probe method and found to agree with the theoretical deductions, except that the concentration of positive ions in the positive column comes out too large. This result indicates the presence of negative mercury ions. (2) The distribution of velocities of electrons is Maxwellian except between striations. (3) The emission of light seems associated more with excitation by electron collision than with ionization and recombination. (4) Conditions for existence of striations. Striations are not found in pure Hg vapor unless the current is small or some substance like H2 is introduced to remove excited atoms. (5) The presence of atomic hydrogen which should be produced in the process of removing excited Hg atoms was proved by use of tungsten oxide. (6) Introduction of He, which cannot remove excited atoms, does not tend to produce striations. (7) The relative concentrations of excited atoms was determined from the optical absorption of subordinate series Hg lines. It was found that excited atoms exist in striations but not in the regions between, and are more numerous if the amount of H2 impurity is reduced.Band spectrum of HgH seems associated with the action of excited Hg atoms on hydrogen, and is emitted as a result of inelastic collisions in striations.

K. T. Compton; Louis A. Turner; W. H. McCurdy

1924-12-01T23:59:59.000Z

430

Emerging Lighting Technology  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emerging Lighting Technology Emerging Lighting Technology Bruce Kinzey Pacific Northwest National Laboratory FUPWG - Portland, OR April 20, 2011 www.ssl.energy.gov 2 | Solid-State Lighting Program GATEWAY Demonstration Program * Purpose: demonstrate new SSL products in real-world applications that save energy, match or improve illumination, and are cost- effective * Demos generate critical field experience providing: - Feedback to manufacturers - Data for utility incentives - Market readiness of specific applications to users - Advancement in lighting knowledge Central Park, NY Photo: Ryan Pyle Smithsonian American Art Museum, Washington, D.C. Photo: Scott Rosenfeld www.ssl.energy.gov 3 | Solid-State Lighting Program LED Product Explosion www.ssl.energy.gov 4 | Solid-State Lighting Program LEDs are Not a Universal Lighting

431

Method for the generation of variable density metal vapors which bypasses the liquidus phase  

DOE Patents (OSTI)

The present invention provides a method for producing a metal vapor that includes the steps of combining a metal and graphite in a vessel to form a mixture; heating the mixture to a first temperature in an argon gas atmosphere to form a metal carbide; maintaining the first temperature for a period of time; heating the metal carbide to a second temperature to form a metal vapor; withdrawing the metal vapor and the argon gas from the vessel; and separating the metal vapor from the argon gas. Metal vapors made using this method can be used to produce uniform powders of the metal oxide that have narrow size distribution and high purity.

Kunnmann, Walter (Stony Brook, NY); Larese, John Z. (Rocky Point, NY)

2001-01-01T23:59:59.000Z

432

SMART LIGHTING SYSTEMS ULTIMATE LIGHTING The Smart Lighting  

E-Print Network (OSTI)

Integration (Holistic Integrated Design) · Sensors as important as LEDs · Interconnected systems (human, building, grid) · Artistic Design Freedom · Lighting is Health, Entertainment, Information and Illumination Cost at any brightness · Chip level integrated electronics THE ERC RESEARCH COVERS THE ENTIRE SUPPLY

Linhardt, Robert J.

433

Mercury Vapor At Mokapu Penninsula Area (Thomas, 1986) | Open Energy  

Open Energy Info (EERE)

Mokapu Penninsula Area (Thomas, 1986) Mokapu Penninsula Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Mokapu Penninsula Area (Thomas, 1986) Exploration Activity Details Location Mokapu Penninsula Area Exploration Technique Mercury Vapor Activity Date Usefulness not useful DOE-funding Unknown Notes The high degree of cultural activity (e.g. residential areas, streets, jet runways, etc.) on Mokapu both limited the extent of the soil geochemical surveys performed and rendered their interpretation much more difficult. Soil mercury concentrations and radon emanometry data on the peninsula showed a few localized high values (Figs 13, 14), but no consistent correlation between the anomalous zones and geologic features could be

434

Detonation wave driven by condensation of supersaturated carbon vapor  

Science Journals Connector (OSTI)

An experimental observation of a detonation wave driven by the energy of condensation of supersaturated carbon vapor is reported. The carbon vapor was formed by the thermal decay of unstable carbon suboxide C3O2 behind shock waves in mixtures containing 10–30% C3O2 in Ar. In the mixture 10% C3O2+Ar the insufficient heat release resulted in a regime of overdriven detonation. In the mixture 20% C3O2+Ar measured values of the pressure and wave velocity coincident with calculated Chapman-Jouguet parameters were attained. In the richest mixture 30% C3O2+Ar an excess heat release caused the slowing down of the condensation rate and the regime of underdriven detonation was observed.

A. Emelianov; A. Eremin; V. Fortov; H. Jander; A. Makeich; H. Gg. Wagner

2009-03-10T23:59:59.000Z

435

Fabrication of solid oxide fuel cell by electrochemical vapor deposition  

DOE Patents (OSTI)

In a high temperature solid oxide fuel cell (SOFC), the deposition of an impervious high density thin layer of electrically conductive interconnector material, such as magnesium doped lanthanum chromite, and of an electrolyte material, such as yttria stabilized zirconia, onto a porous support/air electrode substrate surface is carried out at high temperatures (approximately 1100.degree.-1300.degree. C.) by a process of electrochemical vapor deposition. In this process, the mixed chlorides of the specific metals involved react in the gaseous state with water vapor resulting in the deposit of an impervious thin oxide layer on the support tube/air electrode substrate of between 20-50 microns in thickness. An internal heater, such as a heat pipe, is placed within the support tube/air electrode substrate and induces a uniform temperature profile therein so as to afford precise and uniform oxide deposition kinetics in an arrangement which is particularly adapted for large scale, commercial fabrication of SOFCs.

Brian, Riley (Willimantic, CT); Szreders, Bernard E. (Oakdale, CT)

1989-01-01T23:59:59.000Z

436

Fabrication of solid oxide fuel cell by electrochemical vapor deposition  

DOE Patents (OSTI)

In a high temperature solid oxide fuel cell (SOFC), the deposition of an impervious high density thin layer of electrically conductive interconnector material, such as magnesium doped lanthanum chromite, and of an electrolyte material, such as yttria stabilized zirconia, onto a porous support/air electrode substrate surface is carried out at high temperatures (/approximately/1100/degree/ /minus/ 1300/degree/C) by a process of electrochemical vapor deposition. In this process, the mixed chlorides of the specific metals involved react in the gaseous state with water vapor resulting in the deposit of an impervious thin oxide layer on the support tube/air electrode substrate of between 20--50 microns in thickness. An internal heater, such as a heat pipe, is placed within the support tube/air electrode substrate and induces a uniform temperature profile therein so as to afford precise and uniform oxide deposition kinetics in an arrangement which is particularly adapted for large scale, commercial fabrication of SOFCs.

Riley, B.; Szreders, B.E.

1988-04-26T23:59:59.000Z

437

Specific Mass Estimates for A Vapor Core Reactor With MHD  

SciTech Connect

This study investigated the development of a system concept for space power generation and nuclear electric propulsion based on a vapor core reactor (VCR) with magnetohydrodynamic (MHD) power conversion system, coupled to a magnetoplasma-dynamic (MPD) thruster. The VCR is a liquid-vapor core reactor concept operating with metallic uranium or uranium tetrafluoride (UF{sub 4}) vapor as the fissioning fuel and alkali metals or their fluorides as working fluid in a closed Rankine cycle with MHD energy conversion. Gaseous and liquid-vapor core reactors can potentially provide the highest reactor and cycle temperature among all existing or proposed fission reactor designs. This unique feature makes this reactor concept a very natural and attractive candidate for very high power (10 to 1000 MWe) and low specific mass (0.4 to 5 kg/kWe) nuclear electric propulsion (NEP) applications since the MHD output could be coupled with minimal power conditioning to MPD thrusters or other types of thruster for producing thrust at very high specific impulse (I{sub sp} 1500 to 10,000 s). The exceptional specific mass performance of an optimized VCRMHD- NEP system could lead to a dramatic reduction in the cost and duration of manned or robotic interplanetary as well as interstellar missions. The VCR-MHD-NEP system could enable very efficient Mars cargo transfers or short (<8 month) Mars round trips with less initial mass in low Earth orbit (IMLEO). The system could also enable highly efficient lunar cargo transfer and rapid missions to other destinations throughout the solar system. (authors)

Knight, Travis; Smith, Blair; Anghaie, Samim [Innovative Nuclear Space Power and Propulsion Institute (INSPI), PO Box 116502, University of Florida, Gainesville, FL 32611-6502 (United States)

2002-07-01T23:59:59.000Z

438

Heat Recovery in Distillation by Mechanical Vapor Recompression  

E-Print Network (OSTI)

be classified generally into two types,.aerodynamic and positive displacement (Figure 5). Among the various types of compressors, centrifugal, reciprocating, lobe and screw have been used for vapor recompression. I AXIAL AERODYNAMIC I I CENTRIFUGAL I... speeds of centri fugal compressors make them highly susceptible to erosion from entrained liquid droplets. This ero sion can reduce the efficiency and cause dynamic instability from rotor imbalance and mechanical failure. Next, it is important...

Becker, F. E.; Zakak, A. I.

439

High average power magnetic modulator for metal vapor lasers  

DOE Patents (OSTI)

A three-stage magnetic modulator utilizing magnetic pulse compression designed to provide a 60 kV pulse to a copper vapor laser at a 4.5 kHz repetition rate is disclosed. This modulator operates at 34 kW input power. The circuit includes a step up auto transformer and utilizes a rod and plate stack construction technique to achieve a high packing factor.

Ball, Don G. (Livermore, CA); Birx, Daniel L. (Oakley, CA); Cook, Edward G. (Livermore, CA); Miller, John L. (Livermore, CA)

1994-01-01T23:59:59.000Z

440

Lighting the Night: Technology, Urban Life and the Evolution of Street Lighting [Light in Place  

E-Print Network (OSTI)

May 1912), 783. 8. "New Street Lights Increase Trade 3 5 Perlight, including street light, became part of America'sBeautiful-inspired street­ lights graced wealthy residen­

Holden, Alfred

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Methanol vaporization and injection system for internal combustion engine  

SciTech Connect

An engine equipped with an alcohol vaporization injection system operates as a four stroke cycle diesel engine that transfers the heat of exiting exhaust gases and cylinder head walls to the fuel. The engine runs on alcohol. The alcohol becomes vaporized and its pressure is high enough so that when a valve is opened between the high pressure fuel line and the combustion chamber (when it is at the peak of its compression ratio) enough alcohol will enter the combustion chamber to allow proper combustion. The overall advantages to this type of alcohol vaporization injection system is that it adds relatively few new mechanisms to the spark ignition four cycle internal combustion engine to enable it to operate as a diesel engine with a high thermal efficiency. This alcohol injection system exploits the engine's need for greater volumes of alcohol caused by the alcohol's relatively low heat of combustion (When compared to gasoline) by using this greater volume of fuel to return greater quantities of heat back to the engine to a much greater degree than other fuels can.

Bayley, R.I.

1980-05-06T23:59:59.000Z

442

Program plan for the resolution of tank vapor issues  

SciTech Connect

Since 1987, workers at the Hanford Site waste tank farms in Richland, Washington, have reported strong odors emanating from the large, underground high-level radioactive waste storage tanks. Some of these workers have complained of symptoms (e.g., headaches, nausea) related to the odors. In 1992, the U.S. Department of Energy, which manages the Hanford Site, and Westinghouse Hanford Company determined that the vapor emissions coming from the tanks had not been adequately characterized and represented a potential health risk to workers in the immediate vicinity of the tanks. At that time, workers in certain areas of the tank farms were required to use full-face, supplied-breathing-air masks to reduce their exposure to the fugitive emissions. While use of supplied breathing air reduced the health risks associated with the fugitive emissions, it introduced other health and safety risks (e.g., reduced field of vision, air-line tripping hazards, and heat stress). In 1992, an aggressive program was established to assure proper worker protection while reducing the use of supplied breathing air. This program focuses on characterization of vapors inside the tanks and industrial hygiene monitoring in the tank farms. If chemical filtration systems for mitigation of fugitive emissions are deemed necessary, the program will also oversee their design and installation. This document presents the plans for and approach to resolving the Hanford Site high-level waste tank vapor concerns. It is sponsored by the Department of Energy Office of Environmental Restoration and Waste Management.

Osborne, J.W.; Huckaby, J.L.

1994-05-01T23:59:59.000Z

443

Buildings Energy Data Book: 5.6 Lighting  

Buildings Energy Data Book (EERE)

9 9 Typical Efficacies and Lifetimes of Lamps (1) Current Technology CRI (2) Incandescent 10 - 19 97 Halogen 14 - 20 99 Fluorescent - T5 25 - 55 52 - 75 Fluorescent - T8 35 - 87 7,500 - 20,000 52 - 90 Fluorescent - T12 35 - 92 7,500 - 20,000 50 - 92 Compact Fluorescent 40 - 70 82 Mercury Vapor 25 - 50 15 - 50 Metal Halide 65 - 70 High-Pressure Sodium 22 Low-Pressure Sodium 0 Solid State Lighting 33-97 Note(s): Source(s): 18 - 180 18,000 20 - 100 15,000 - 50,000 1) Theoretical maximum luminous efficacy of white light is 220 lumens/Watt. 2) CRI = Color Rendering Index, which indicates a lamp's ability to show natural colors. 3) The DOE Solid State Lighting program has set an efficacy goal twice that of fluorescent lights (160 lumen per Watt). DOE, EERE, Building Technology Program/Navigant Consulting, U.S. Lighting Market Characterization, Volume I: National Lighting Inventory and Energy

444

Solid-State Lighting: Pedestrian-Friendly Nighttime Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

Pedestrian-Friendly Nighttime Pedestrian-Friendly Nighttime Lighting to someone by E-mail Share Solid-State Lighting: Pedestrian-Friendly Nighttime Lighting on Facebook Tweet about Solid-State Lighting: Pedestrian-Friendly Nighttime Lighting on Twitter Bookmark Solid-State Lighting: Pedestrian-Friendly Nighttime Lighting on Google Bookmark Solid-State Lighting: Pedestrian-Friendly Nighttime Lighting on Delicious Rank Solid-State Lighting: Pedestrian-Friendly Nighttime Lighting on Digg Find More places to share Solid-State Lighting: Pedestrian-Friendly Nighttime Lighting on AddThis.com... Conferences & Meetings Presentations Publications Webcasts Videos Tools Pedestrian-Friendly Nighttime Lighting This November 19, 2013 webinar presented issues and considerations related to pedestrian-friendly nighttime lighting, such as color rendering, safety,

445

Data:1c312b9d-31a5-42ac-9124-09670fe92d64 | Open Energy Information  

Open Energy Info (EERE)

d-31a5-42ac-9124-09670fe92d64 d-31a5-42ac-9124-09670fe92d64 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Norcross, Georgia (Utility Company) Effective date: 2008/04/01 End date if known: Rate name: Security Lighting Service (High Pressure Sodium Vapor 1,000W Lamp) Sector: Lighting Description: To property owners and tenants in the proximity of low voltage distribution lines of the City of Norcross. Service may be used to illuminate public thoroughfares and/or private outdoor areas, including, but not limited to, roadways, parking lots and yards. Fixture type: High Pressure Sodium Vapor Lamp Wattage: 1,000 Monthly Rate: $28.00 per fixture

446

Data:0f15a162-c64e-4472-9840-ef468a1f41b1 | Open Energy Information  

Open Energy Info (EERE)

5a162-c64e-4472-9840-ef468a1f41b1 5a162-c64e-4472-9840-ef468a1f41b1 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Norcross, Georgia (Utility Company) Effective date: 2008/04/01 End date if known: Rate name: Security Lighting Service (High Pressure Sodium Vapor 400W Lamp) Sector: Lighting Description: To property owners and tenants in the proximity of low voltage distribution lines of the City of Norcross. Service may be used to illuminate public thoroughfares and/or private outdoor areas, including, but not limited to, roadways, parking lots and yards. Fixture type: High Pressure Sodium Vapor Lamp Wattage: 400 Monthly Rate: $16.00 per fixture

447

Data:B1edf565-9734-46fa-8177-9f7294ae0587 | Open Energy Information  

Open Energy Info (EERE)

edf565-9734-46fa-8177-9f7294ae0587 edf565-9734-46fa-8177-9f7294ae0587 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Norcross, Georgia (Utility Company) Effective date: 2008/04/01 End date if known: Rate name: Security Lighting Service (Mercury Vapor 400W Lamp) Sector: Lighting Description: To property owners and tenants in the proximity of low voltage distribution lines of the City of Norcross. Service may be used to illuminate public thoroughfares and/or private outdoor areas, including, but not limited to, roadways, parking lots and yards. Fixture type: Mercury Vapor Lamp Wattage: 400 Monthly Rate: $16.00 per fixture

448

Data:C8848f40-2853-49aa-910c-f404d0de3ad4 | Open Energy Information  

Open Energy Info (EERE)

f40-2853-49aa-910c-f404d0de3ad4 f40-2853-49aa-910c-f404d0de3ad4 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Norcross, Georgia (Utility Company) Effective date: 2008/04/01 End date if known: Rate name: Security Lighting Service (High Pressure Sodium Vapor 100W Lamp) Sector: Lighting Description: To property owners and tenants in the proximity of low voltage distribution lines of the City of Norcross. Service may be used to illuminate public thoroughfares and/or private outdoor areas, including, but not limited to, roadways, parking lots and yards. Fixture type: High Pressure Sodium Vapor Lamp Wattage: 100 Monthly Rate: $7.00 per fixture

449

Data:Dfef1652-2729-4b5c-85c5-b5ec5bd650d1 | Open Energy Information  

Open Energy Info (EERE)

Dfef1652-2729-4b5c-85c5-b5ec5bd650d1 Dfef1652-2729-4b5c-85c5-b5ec5bd650d1 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Norcross, Georgia (Utility Company) Effective date: 2008/04/01 End date if known: Rate name: Security Lighting Service (Mercury Vapor 175W Lamp) Sector: Lighting Description: To property owners and tenants in the proximity of low voltage distribution lines of the City of Norcross. Service may be used to illuminate public thoroughfares and/or private outdoor areas, including, but not limited to, roadways, parking lots and yards. Fixture type: Mercury Vapor Lamp Wattage: 175 Monthly Rate: $7.00 per fixture

450

Lighting Group: Software  

NLE Websites -- All DOE Office Websites (Extended Search)

Software Software Lighting Software The Lighting Group has developed several computer programs in the course of conducting research on energy efficient lighting. Several of these programs have proven useful outside the research environment. One of the most popular programs for advanced lighting applications is Radiance. For more information on this program and its availability, click on the link below. RADIANCE Radiance is a suite of programs for the analysis and visualization of lighting in design. The primary advantage of Radiance over simpler lighting calculation and rendering tools is that there are no limitations on the geometry or the materials that may be simulated. Radiance is used by architects and engineers to predict illumination, visual quality and appearance of innovative design spaces, and by researchers to evaluate new

451

The influence of prestrained metalorganic vapor phase epitaxial gallium-nitride templates on hydride vapor phase epitaxial growth  

Science Journals Connector (OSTI)

We have varied the strain situation in metalorganic vapor phase epitaxial (MOVPE) grown gallium-nitride (GaN) by exchanging the nucleation layer and by inserting a submono-Si x N y -interlayer in the first few hundred nanometers of growth on sapphire substrates. The influence on the MOVPE template and subsequent hydride vapor phase epitaxial (HVPE) growth could be shown by in-situ measurements of the sample curvature. Using the results of these investigations we have established a procedure to confine the curvature development in MOVPE and HVPE growth to a minimum. By increasing the layer thickness in HVPE we could create self-separated freestanding GaN layers with small remaining curvature.

2014-01-01T23:59:59.000Z

452

Tank 241-TX-118 headspace gas and vapor characterization results for samples collected in September 1994 and December 1994  

SciTech Connect

Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

Huckaby, J.L. [Pacific Northwest Lab., Richland, WA (United States); Bratzel, D.R. [Westinghouse Hanford Co., Richland, WA (United States)

1995-09-27T23:59:59.000Z

453

National Synchrotron Light Source  

ScienceCinema (OSTI)

A tour of Brookhaven's National Synchrotron Light Source (NSLS), hosted by Associate Laboratory Director for Light Sources, Stephen Dierker. The NSLS is one of the world's most widely used scientific research facilities, hosting more than 2,500 guest researchers each year. The NSLS provides intense beams of infrared, ultraviolet, and x-ray light for basic and applied research in physics, chemistry, medicine, geophysics, environmental, and materials sciences.

BNL

2009-09-01T23:59:59.000Z

454

High efficiency incandescent lighting  

DOE Patents (OSTI)

Incandescent lighting structure. The structure includes a thermal emitter that can, but does not have to, include a first photonic crystal on its surface to tailor thermal emission coupled to, in a high-view-factor geometry, a second photonic filter selected to reflect infrared radiation back to the emitter while passing visible light. This structure is highly efficient as compared to standard incandescent light bulbs.

Bermel, Peter; Ilic, Ognjen; Chan, Walker R.; Musabeyoglu, Ahmet; Cukierman, Aviv Ruben; Harradon, Michael Robert; Celanovic, Ivan; Soljacic, Marin

2014-09-02T23:59:59.000Z

455

Accident Performance of Light Water Reactor Cladding Materials  

SciTech Connect

During a loss of coolant accident as experienced at Fukushima, inadequate cooling of the reactor core forces component temperatures ever higher where they must withstand aggressive chemical environments. Conventional zirconium cladding alloys will readily oxidize in the presence of water vapor at elevated temperatures, rapidly degrading and likely failing. A cladding breach removes the critical barrier between actinides and fission products and the coolant, greatly increasing the probability of the release of radioactivity in the event of a containment failure. These factors have driven renewed international interest in both study and improvement of the materials used in commercial light water reactors. Characterization of a candidate cladding alloy or oxidation mitigation technique requires understanding of both the oxidation kinetics and hydrogen production as a function of temperature and atmosphere conditions. Researchers in the MST division supported by the DOE-NE Fuel Cycle Research and Development program are working to evaluate and quantify these parameters across a wide range of proposed cladding materials. The primary instrument employed is a simultaneous thermal analyzer (STA) equipped with a specialized water vapor furnace capable of maintaining temperatures above 1200 C in a range of atmospheres and water vapor contents. The STA utilizes thermogravimetric analysis and a coupled mass spectrometer to measure in situ oxidation and hydrogen production of candidate materials. This capability is unprecedented in study of materials under consideration for reactor cladding use, and is currently being expanded to investigate proposed coating techniques as well as the effect of coating defects on corrosion resistance.

Nelson, Andrew T. [Los Alamos National Laboratory

2012-07-24T23:59:59.000Z

456

Domestic Lighting and Heating  

Science Journals Connector (OSTI)

... a 14 × 22 feet room with a nice spacious window at each end admitting surreptitious draughts in proportion to the amount of light they let in. ...

M. GHEURY DE BRAY

1926-02-06T23:59:59.000Z

457

Comparing Light Bulbs  

Energy.gov (U.S. Department of Energy (DOE))

In this exercise, students will use a light to demonstrate the difference between being energy-efficient and energy-wasteful, and learn what energy efficiency means.

458

Headspace vapor characterization of Hanford Waste Tank 241-T-110: Results from samples collected on August 31, 1995. Tank Vapor Characterization Project  

SciTech Connect

This report describes the results of vapor samples taken from the headspace of waste storage tank 241-T-110 (Tank T-110) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5056. Samples were collected by WHC on August 31, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

McVeety, B.D.; Thomas, B.L.; Evans, J.C. [and others

1996-05-01T23:59:59.000Z

459

Final Report for ARM Project Measuring 4-D Water Vapor Fields with GPS  

SciTech Connect

Water vapor is a primary element in the Earth’s climate system. Atmospheric water vapor is central to cloud processes, radiation transfer, and the hydrological cycle. Using funding from Department of Energy (DOE) grant DE-FG03-02ER63327, the University Corporation for Atmospheric Research (UCAR) developed new observational techniques to measure atmospheric water vapor and applied these techniques to measure four dimensional water vapor fields throughout the United States Southern Great Plains region. This report summarizes the development of a new observation from ground based Global Positioning System (GPS) stations called Slant Water Vapor (SW) and it’s utilization in retrieving four dimensional water vapor fields. The SW observation represents the integrated amount of water vapor between a GPS station and a transmitting satellite. SW observations provide improved temporal and spatial sampling of the atmosphere when compared to column-integrated quantities such as preciptitable water vapor (PW). Under funding from the DOE Atmospheric Radiation Measurement (ARM) program, GPS networks in the Southern Great Plains (SGP) region were deployed to retrieve SW to improve the characterization of water vapor throughout the region. These observations were used to estimate four dimensional water vapor fields using tomographic approaches and through assimilation into the MM5 numerical weather model.

Braun, John

2006-02-06T23:59:59.000Z

460

Lakeview Light and Power - Commercial Lighting Rebate Program | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lakeview Light and Power - Commercial Lighting Rebate Program Lakeview Light and Power - Commercial Lighting Rebate Program Lakeview Light and Power - Commercial Lighting Rebate Program < Back Eligibility Commercial Fed. Government Local Government Nonprofit State Government Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info Funding Source Funded by Bonneville Power Administration Expiration Date 9/1/2013 State District of Columbia Program Type Utility Rebate Program Rebate Amount Commercial Lighting Installation: Up to 70% of cost Provider Lakeview Light and Power Lakeview Light and Power offers a commercial lighting rebate program. Rebates apply to the installation of energy efficient lighting retrofits in non-residential buildings. The rebate program is funded by BPA and ends in September of 2010 or earlier if the funding is exhausted. Lakeview Light

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Technique for compressing light intensity ranges utilizing a specifically designed liquid crystal notch filter  

DOE Patents (OSTI)

A pin hole camera assembly for use in viewing an object having a relatively large light intensity range, for example a crucible containing molten metal in an atomic vapor laser isotope separation (AVLIS) system is disclosed herein. The assembly includes means for optically compressing the light intensity range appearing at its input sufficient to make it receivable and decipherable by a standard video camera. To accomplish this, the assembly utilizes the combination of interference filter and a liquid crystal notch filter. The latter which preferably includes a cholesteric liquid crystal arrangement is configured to pass light at all wavelengths, except a relatively narrow wavelength band which defines the filter's notch, and includes means for causing the notch to vary to at least a limited extent with the intensity of light at its light incidence surface.

Rushford, Michael C. (Livermore, CA)

1988-01-01T23:59:59.000Z

462

AIRPORT LIGHTING Session Highlights  

E-Print Network (OSTI)

. These sessions were designed to offer practical-yet-specialized training and information outreach for personnel information on airport lighting and navigational aid equipment selection, funding, maintenance, and operation known as AirTAP, sponsored three airport-lighting training sessions at different locations in Minnesota

Minnesota, University of

463

LED Lighting Facts  

Energy.gov (U.S. Department of Energy (DOE))

DOE's LED Lighting Facts® program showcases LED products for general illumination from manufacturers who commit to testing products and reporting performance results according to industry standards. For lighting buyers, designers, and energy efficiency programs, the program provides information essential to evaluating SSL products.

464

Light intensity compressor  

DOE Patents (OSTI)

In a system for recording images having vastly differing light intensities over the face of the image, a light intensity compressor is provided that utilizes the properties of twisted nematic liquid crystals to compress the image intensity. A photoconductor or photodiode material that is responsive to the wavelength of radiation being recorded is placed adjacent a layer of twisted nematic liquid crystal material. An electric potential applied to a pair of electrodes that are disposed outside of the liquid crystal/photoconductor arrangement to provide an electric field in the vicinity of the liquid crystal material. The electrodes are substantially transparent to the form of radiation being recorded. A pair of crossed polarizers are provided on opposite sides of the liquid crystal. The front polarizer linearly polarizes the light, while the back polarizer cooperates with the front polarizer and the liquid crystal material to compress the intensity of a viewed scene. Light incident upon the intensity compressor activates the photoconductor in proportion to the intensity of the light, thereby varying the field applied to the liquid crystal. The increased field causes the liquid crystal to have less of a twisting effect on the incident linearly polarized light, which will cause an increased percentage of the light to be absorbed by the back polarizer. The intensity of an image may be compressed by forming an image on the light intensity compressor.

Rushford, Michael C. (Livermore, CA)

1990-01-01T23:59:59.000Z

465

Explosively pumped laser light  

DOE Patents (OSTI)

A single shot laser pumped by detonation of an explosive in a shell casing. The shock wave from detonation of the explosive causes a rare gas to luminesce. The high intensity light from the gas enters a lasing medium, which thereafter outputs a pulse of laser light to disable optical sensors and personnel.

Piltch, Martin S. (Los Alamos, NM); Michelotti, Roy A. (Los Alamos, NM)

1991-01-01T23:59:59.000Z

466

Columbia Water and Light - HVAC and Lighting Efficiency Rebates |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Columbia Water and Light - HVAC and Lighting Efficiency Rebates Columbia Water and Light - HVAC and Lighting Efficiency Rebates Columbia Water and Light - HVAC and Lighting Efficiency Rebates < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Lighting: 50% of invoiced cost up to $22,500 Program Info State Missouri Program Type Utility Rebate Program Rebate Amount HVAC Replacements: $570 - $3,770 Lighting: $300/kW reduction or half of project cost Provider Columbia Water and Light Columbia Water and Light (CWL) offers rebates to its commercial and industrial customers for the purchase of high efficiency HVAC installations and efficient lighting. Incentives for certain measures are based upon the

467

Induction Lighting: An Old Lighting Technology Made New Again | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Induction Lighting: An Old Lighting Technology Made New Again Induction Lighting: An Old Lighting Technology Made New Again Induction Lighting: An Old Lighting Technology Made New Again July 27, 2009 - 5:00am Addthis John Lippert Induction lighting is one of the best kept secrets in energy-efficient lighting. Simply stated, induction lighting is essentially a fluorescent light without electrodes or filaments, the items that frequently cause other bulbs to burn out quickly. Thus, many induction lighting units have an extremely long life of up to 100,000 hours. To put this in perspective, an induction lighting system lasting 100,000 hours will last more than 11 years in continuous 24/7 operation, and 25 years if operated 10 hours a day. The technology, however, is far from new. Nikola Tesla demonstrated induction lighting in the late 1890s around the same time that his rival,

468

Mercury Vapor At Salt Wells Area (Henkle, Et Al., 2005) | Open Energy  

Open Energy Info (EERE)

Mercury Vapor At Salt Wells Area (Henkle, Et Al., 2005) Mercury Vapor At Salt Wells Area (Henkle, Et Al., 2005) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Salt Wells Area (Henkle, Et Al., 2005) Exploration Activity Details Location Salt Wells Area Exploration Technique Mercury Vapor Activity Date - 2005 Usefulness useful DOE-funding Unknown Exploration Basis Adsorbed mercury soil geochemical surveys and radiometric geophysical surveys were carried out in conjunction with geologic mapping to test the application of these ground-based techniques to geothermal exploration at three prospects in Nevada by Henkle Jr. et al. in 2005. Mercury soil vapor surveys were not widely used in geothermal exploration in the western US at the time, although the association of mercury vapors with geothermal

469

MEASUREMENTS AND RETRIEVALS FROM A NEW 183-GHz WATER VAPOR RADIOMETER IN  

NLE Websites -- All DOE Office Websites (Extended Search)

MEASUREMENTS AND RETRIEVALS FROM A NEW 183-GHz WATER VAPOR RADIOMETER IN MEASUREMENTS AND RETRIEVALS FROM A NEW 183-GHz WATER VAPOR RADIOMETER IN THE ARCTIC Cadeddu, Maria Argonne National Laboratory Category: Instruments A new G-band (183 GHz) vapor radiometer (GVR), developed and built by Prosensing Inc. (http://www.prosensing.com), was deployed in Barrow, Alaska, in April 2005. The radiometer was deployed as part of the ongoing Atmospheric Radiation Measurement (ARM) program's effort to improve water vapor retrievals in the cold, dry Arctic environment. The instrument measures brightness temperatures from four double sideband channels centered at 1, 3, 7, and 14 GHz from the 183.31-GHz water vapor line. Atmospheric emission in this spectral region is primarily due to water vapor, with some influence from liquid water. The GVR will remain in Barrow

470

Lighting fundamentals handbook: Lighting fundamentals and principles for utility personnel  

SciTech Connect

Lighting accounts for approximately 30% of overall electricity use and demand in commercial buildings. This handbook for utility personnel provides a source of basic information on lighting principles, lighting equipment, and other considerations related to lighting design. The handbook is divided into three parts. Part One, Physics of Light, has chapters on light, vision, optics, and photometry. Part Two, Lighting Equipment and Technology, focuses on lamps, luminaires, and lighting controls. Part Three, Lighting Design Decisions, deals with the manner in which lighting design decisions are made and reviews relevant methods and issues. These include the quantity and quality of light needed for visual tasks, calculation methods for verifying that lighting needs are satisfied, lighting economics and methods for evaluating investments in efficient lighting systems, and miscellaneous design issues including energy codes, power quality, photobiology, and disposal of lighting equipment. The handbook contains a discussion of the role of the utility in promoting the use of energy-efficient lighting. The handbook also includes a lighting glossary and a list of references for additional information. This convenient and comprehensive handbook is designed to enable utility lighting personnel to assist their customers in developing high-quality, energy-efficient lighting systems. The handbook is not intended to be an up-to-date reference on lighting products and equipment.

Eley, C.; Tolen, T. (Eley (Charles) Associates, San Francisco, CA (United States)); Benya, J.R. (Luminae Souter Lighting Design, San Francisco, CA (United States))

1992-12-01T23:59:59.000Z

471

Light and Bread Mold  

NLE Websites -- All DOE Office Websites (Extended Search)

Light and Bread Mold Light and Bread Mold Name: CHASE Location: N/A Country: N/A Date: N/A Question: HOW CAN I EFICTIVELY TEST THE EFFECTS OF LIGHT ON BREAD MOLD? Replies: Hello Chase, In order to test the effects of light on bread mould you need to set up an experiment. There are two things you need to have in your experiment to make it a good experiment: 1. A 'control'. 2. Replicates 1. The 'control' Obviously in order to test the effects of light on bread mold you will need to actually shine some light on some bread mold and see what happens. This is your 'treatment'. However, it is vitally important that you know what would have happened without the treatment (in this case added light). Let's pretend that you do a test a you find that the bread mold under the light actually dies. How do you know if your bread mold died because light was added or because at that time of year all bread mold would die naturally or because by adding light you caused the temperature to rise and that killed the bread mold? The answer is that you do not know unless you have taken the trouble to find out with anouther test called the 'control'. The 'control' is a piece of bread mold, identical to the 'treatment' bread mold, which is placed in identical conditions to the 'treatment' piece of bread mold except that light is removed. Your 'control' piece of bread mold will need to be (to the best of your abillity) at the same temperature, in the same area, at similar humidity, etc. Part of the skill of designing a scientific experiment is being able think of all the possible things which might be affecting the bread mold and keeping them the same in both the 'treatment' and the 'control' (except, of course, for the presence of light) so that when you find a difference between the 'treatment' and the 'control' you are sure that it is the result of the light rather than something else.

472

Chemical vapor deposition of amorphous semiconductor films. Final subcontract report  

SciTech Connect

Chemical vapor deposition (CVD) from higher order silanes has been studied for fabricating amorphous hydrogenated silicon thin-film solar cells. Intrinsic and doped a-Si:H films were deposited in a reduced-pressure, tubular-flow reactor, using disilane feed-gas. Conditions for depositing intrinsic films at growth rates up to 10 A/s were identified. Electrical and optical properties, including dark conductivity, photoconductivity, activation energy, optical absorption, band-gap and sub-band-gap absorption properties of CVD intrinsic material were characterized. Parameter space for depositing intrinsic and doped films, suitable for device analysis, was identified.

Rocheleau, R.E.

1984-12-01T23:59:59.000Z

473

A thermoacoustic oscillator powered by vaporized water and ethanol  

Science Journals Connector (OSTI)

We measure the temperature difference required to drive a thermoacoustic oscillator containing air water vapor and liquid water as the working fluids. The oscillator is composed of a large tube containing an array of narrow tubes connected at one end to a tank of liquid water. When the water is heated the temperature difference across the tube array increases until thermoacoustic oscillations occur. The temperature difference at the onset of oscillation is measured to be 56 ? ° C significantly smaller (by ? 200 ? ° C ) than the temperature measured when the tank is filled with dry air instead of water. The temperature difference can be further reduced to 47 ? ° C by using ethanol instead of water.

Daisuke Noda; Yuki Ueda

2013-01-01T23:59:59.000Z

474

Io - Are vapor explosions responsible for the 5-micron outbursts  

SciTech Connect

It is proposed that a vapor explosion of a submerged pool of liquid sulfur will remove the crust overlying an area of about 50-km diam. Thermal radiation from the exposed liquid sulfur pool with a surface temperature of 600 K is then presumed to be responsible for the 5-micron outbursts that have been observed. The explosive volcanoes are expected to leave black sulfur calderas, which are, indeed, found on the surface. The 5-micron outburst observed by Sinton (1980), on June 11, 1979 (UT), is identified with a new caldera found on Voyager 2 photographs but which had not been present on Voyager 1 pictures.

Sinton, W.M.

1980-01-01T23:59:59.000Z

475

Optical waveguides in SBN by zinc vapor diffusion  

E-Print Network (OSTI)

at 600'C for a 12. 5 i1m Wide 1000'C Zinc Vapor Diffused SBN:60 Waveguide Measured at X = 0. 81 pm. IV. SBN:60 Amplitude Modulator Results . . . . . V. SBN:60 Mach-Zehnder Interferometer Results. . . . VI. Voltage-Length Product Comparison...: (a) extraordinary (TM), (b) 1. 5 x ordinary (TE). 12. Surface damage on SBN:60 diffused at 1000'C with an SiOz diffusion mask. 13. Zinc in-diffusion in SBN:60 25 . . . . . 26 . . . . . 27 . . . . . 28 29 14. Barium out-diffuison in SBN:60...

Quinn, Jeffrey Dale

1991-01-01T23:59:59.000Z

476

Combustion chemical vapor deposited coatings for thermal barrier coating systems  

SciTech Connect

The new deposition process, combustion chemical vapor deposition, shows a great deal of promise in the area of thermal barrier coating systems. This technique produces dense, adherent coatings, and does not require a reaction chamber. Coatings can therefore be applied in the open atmosphere. The process is potentially suitable for producing high quality CVD coatings for use as interlayers between the bond coat and thermal barrier coating, and/or as overlayers, on top of thermal barrier coatings. In this report, the evaluation of alumina and ceria coatings on a nickel-chromium alloy is described.

Hampikian, J.M.; Carter, W.B. [Georgia Institute of Technology, Atlanta, GA (United States). School of Materials Science and Engineering

1995-12-31T23:59:59.000Z

477

Unusual thermopower of inhomogeneous graphene grown by chemical vapor deposition  

SciTech Connect

We report on thermopower (TEP) and resistance measurements of inhomogeneous graphene grown by chemical vapor deposition (CVD). Unlike the conventional resistance of pristine graphene, the gate-dependent TEP shows a large electron-hole asymmetry. This can be accounted for by inhomogeneity of the CVD-graphene where individual graphene regions contribute with different TEPs. At the high magnetic field and low temperature, the TEP has large fluctuations near the Dirac point associated with the disorder in the CVD-graphene. TEP measurements reveal additional characteristics of CVD-graphene, which are difficult to obtain from the measurement of resistance alone.

Nam, Youngwoo, E-mail: youngwoo.nam@chalmers.se [Department of Physics and Astronomy, Seoul National University, Seoul 151-747 (Korea, Republic of); Department of Microtechnology and Nanoscience, Chalmers University of Technology, SE-412 96 Gothenburg (Sweden); Sun, Jie; Lindvall, Niclas; Yurgens, August [Department of Microtechnology and Nanoscience, Chalmers University of Technology, SE-412 96 Gothenburg (Sweden); Jae Yang, Seung; Rae Park, Chong [Department of Materials Science and Engineering, Seoul National University, Seoul 151-747 (Korea, Republic of); Woo Park, Yung [Department of Physics and Astronomy, Seoul National University, Seoul 151-747 (Korea, Republic of)

2014-01-13T23:59:59.000Z

478

Dosimeter for monitoring vapors and aerosols of organic compounds  

DOE Patents (OSTI)

A dosimeter is provided for collecting and detecting vapors and aerosols of organic compounds. The dosimeter comprises a lightweight, passive device that can be conveniently worn by a person as a badge or placed at a stationary location. The dosimeter includes a sample collector comprising a porous web treated with a chemical for inducing molecular displacement and enhancing phosphorescence. Compounds are collected onto the web by molecular diffusion. The web also serves as the sample medium for detecting the compounds by a room temperature phosphorescence technique. 7 figs.

Vo-Dinh, T.

1987-07-14T23:59:59.000Z

479

Data:Dda78296-ecb4-4a4b-b8cc-2417fbc15092 | Open Energy Information  

Open Energy Info (EERE)

8296-ecb4-4a4b-b8cc-2417fbc15092 8296-ecb4-4a4b-b8cc-2417fbc15092 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Bozrah Light & Power Company Effective date: 2013/03/01 End date if known: Rate name: Street and Area Lighting Service Mercury Vapor 250W - Overhead Sector: Lighting Description: For all street lighting fixtures served from, attached to and supported by the Company's existing overhead distribution facilities suitable for supplying the service requested. The Company will furnish, maintain and operate lamps in its standard fixtures. Available only to manufacturers whose Standard Industrial Classification (SIC) codes are between 2000 and 3999 who are exempt from the Connecticut Gross Earnings Tax.

480

Data:22196800-78e9-41ff-b268-f230aa1213e8 | Open Energy Information  

Open Energy Info (EERE)

800-78e9-41ff-b268-f230aa1213e8 800-78e9-41ff-b268-f230aa1213e8 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Bozrah Light & Power Company Effective date: 2013/03/01 End date if known: Rate name: Street and Area Lighting Service Mercury Vapor 175W - Underground Sector: Lighting Description: For all street lighting fixtures served from, attached to and supported by the Company's existing overhead distribution facilities suitable for supplying the service requested. The Company will furnish, maintain and operate lamps in its standard fixtures. Available only to manufacturers whose Standard Industrial Classification (SIC) codes are between 2000 and 3999 who are exempt from the Connecticut Gross Earnings Tax.

Note: This page contains sample records for the topic "vapor light fixtures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Data:83b73748-f24a-4ab2-9fac-07c4b8ab0095 | Open Energy Information  

Open Energy Info (EERE)

8-f24a-4ab2-9fac-07c4b8ab0095 8-f24a-4ab2-9fac-07c4b8ab0095 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Edgecombe-Martin County E M C Effective date: 2006/08/01 End date if known: Rate name: SECURITY LIGHTING SERVICE Mercury Vapor 175 W Sector: Lighting Description: AVAILABILITY: Electric service is available under this schedule for lighting of outdoors areas when the Cooperative owns the fixtures. The Cooperative will install fixtures on its distribution system poles and provide illumination from dusk to dawn. SERVICE: Installation of any security light requires a deposit of $30.

482

Data:Cd7857b7-6677-4007-8432-fabb92878480 | Open Energy Information  

Open Energy Info (EERE)

857b7-6677-4007-8432-fabb92878480 857b7-6677-4007-8432-fabb92878480 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Nashville Electric Service Effective date: 2012/06/01 End date if known: Rate name: Outdoor Lighting Mercury Vapor or Incandescent 175w Sector: Lighting Description: PART B--CHARGES FOR OUTDOOR LIGHTING FOR INDIVIDUAL CUSTOMERS The above charges in this Part B are limited to service from a photoelectrically controlled standard lighting fixture installed on a pole already in place. If the customer wishes to have the fixture installed at a location other than on a pole already in place, Distributor may apply an additional monthly charge.

483

Data:65fcc006-4e32-425d-837d-7dce1ad13c67 | Open Energy Information  

Open Energy Info (EERE)

fcc006-4e32-425d-837d-7dce1ad13c67 fcc006-4e32-425d-837d-7dce1ad13c67 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Nashville Electric Service Effective date: 2012/06/01 End date if known: Rate name: Outdoor Lighting Mercury Vapor or Incandescent 250w Sector: Lighting Description: PART B--CHARGES FOR OUTDOOR LIGHTING FOR INDIVIDUAL CUSTOMERS The above charges in this Part B are limited to service from a photoelectrically controlled standard lighting fixture installed on a pole already in place. If the customer wishes to have the fixture installed at a location other than on a pole already in place, Distributor may apply an additional monthly charge.

484

The Prospects of Alternatives to Vapor Compression Technology for Space Cooling and Food Refrigeration Applications  

SciTech Connect

Five alternatives to vapor compression technology were qualitatively evaluated to determine their prospects for being better than vapor compression for space cooling and food refrigeration applications. The results of the assessment are summarized in the report. Overall, thermoacoustic and magnetic technologies were judged to have the best prospects for competing with vapor compression technology, with thermotunneling, thermoelectric, and thermionic technologies trailing behind in that order.

Brown, Daryl R.; Dirks, James A.; Fernandez, Nicholas; Stout, Tyson E.

2010-03-31T23:59:59.000Z

485

Lighting Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting Basics Lighting Basics Lighting Basics August 15, 2013 - 5:12pm Addthis Text Version There are many different types of artificial lights, all of which have different applications and uses. Types of lighting include: Fluorescent Lighting High-intensity Discharge Lighting Incandescent Lighting LED Lighting Low-pressure Sodium Lighting. Which type is best depends on the application. See the chart below for a comparison of lighting types. Lighting Comparison Chart Lighting Type Efficacy (lumens/watt) Lifetime (hours) Color Rendition Index (CRI) Color Temperature (K) Indoors/Outdoors Fluorescent Straight Tube 30-110 7000-24,000 50-90 (fair to good) 2700-6500 (warm to cold) Indoors/outdoors Compact Fluorescent 50-70 10,000 65-88 (good) 2700-6500 (warm to cold) Indoors/outdoors

486

A thermodynamics based analysis of exergy destruction in vapor compression cycle systems.  

E-Print Network (OSTI)

??In the last few decades, vapor-compression cycle systems (VCSs) have undergone many advances in actuation, allowing for variable aperture valves, variable speed compressors, and variable… (more)

Kania, Megan

2013-01-01T23:59:59.000Z

487

Synthesis and Characterization of Magnetic Nanowires Prepared by Chemical Vapor Deposition.  

E-Print Network (OSTI)

??Various metal silicide and germanide magnetic nanowires were synthesized using a home-built CVD [chemical vapor deposition] system. The morphology, composition, and magnetic properties of the… (more)

Tang, Siwei

2014-01-01T23:59:59.000Z

488

Liquid fuel vaporizer and combustion chamber having an adjustable thermal conductor  

DOE Patents (OSTI)

The efficiency and effectiveness of apparatuses for vaporizing and combusting liquid fuel can be improved using thermal conductors. For example, an apparatus having a liquid fuel vaporizer and a combustion chamber can be characterized by a thermal conductor that conducts heat from the combustion chamber to the vaporizer. The thermal conductor can be a movable member positioned at an insertion depth within the combustion chamber that corresponds to a rate of heat conduction from the combustion chamber to the vaporizer. The rate of heat conduction can, therefore, be adjusted by positioning the movable member at a different insertion depth.

Powell, Michael R; Whyatt, Greg A; Howe, Daniel T; Fountain, Matthew S

2014-03-04T23:59:59.000Z

489