Powered by Deep Web Technologies
Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and  

E-Print Network [OSTI]

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and HID (high-intensity discharge) lamps and all other mercury containing labeled for shipment to a recycling plant for mercury, glass and aluminum recovery. The beneficial re

Baker, Chris I.

2

All mercury lamps contain small amounts of mercury. An electric current passes through the lamp and vaporizes the mercury to generate light. Recycling mercury containing lamps protects human health and our environment from heavy  

E-Print Network [OSTI]

All mercury lamps contain small amounts of mercury. An electric current passes through the lamp and vaporizes the mercury to generate light. Recycling mercury containing lamps protects human health and our the environment by recycling universal wastes, contact EH&S at (949) 824-6200 or visit: www.ehs.uci.edu Mercury

George, Steven C.

3

Mercury Vapor Release from Broken Compact Fluorescent Lamps and In Situ Capture by New Nanomaterial Sorbents  

Science Journals Connector (OSTI)

There is one report of Hg poisoning (acrodynia) in a child exposed to broken tube-type fluorescents in a detailed case study presented by Tunnessen et al. (6). ... Similar release patterns but lower amounts were seen for spent bulbs (example result 90 ?g in 24 h) or from the fracture site of a new bulb after glass removal to simulate cleanup. ... Artificial lighting systems are transitioning from incandescent to compact fluorescent lamp (CFL) and light-emitting diode (LED) bulbs in response to the U.S. Energy Independence and Security Act and the EU Ecodesign Directive, which leads to energy ... ...

Natalie C. Johnson; Shawn Manchester; Love Sarin; Yuming Gao; Indrek Kulaots; Robert H. Hurt

2008-06-27T23:59:59.000Z

4

Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg.sup.196 enrichment  

DOE Patents [OSTI]

The present invention is directed to a method of eliminating the cold spot zones presently used on Hg.sup.196 isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

Grossman, Mark W. (Belmont, MA)

1993-01-01T23:59:59.000Z

5

Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg[sup 196] enrichment  

DOE Patents [OSTI]

The present invention is directed to a method of eliminating the cold spot zones presently used on Hg[sup 196] isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

Grossman, M.W.

1993-02-16T23:59:59.000Z

6

Beyond Tesla and Edison: Other Luminaries from the Age of Electricity |  

Broader source: Energy.gov (indexed) [DOE]

Tesla and Edison: Other Luminaries from the Age of Tesla and Edison: Other Luminaries from the Age of Electricity Beyond Tesla and Edison: Other Luminaries from the Age of Electricity November 25, 2013 - 1:30pm Addthis Electricity pioneer Charles Proteus Steinmetz (center in light-colored suit) poses with Albert Einstein (immediate left) and other inventors at the RCA Brunswick, New Jersey, wireless station in 1921. | Photo courtesy of Franklin Township Public Library Archive. Electricity pioneer Charles Proteus Steinmetz (center in light-colored suit) poses with Albert Einstein (immediate left) and other inventors at the RCA Brunswick, New Jersey, wireless station in 1921. | Photo courtesy of Franklin Township Public Library Archive. Rob Roberts Rob Roberts Director of Digital Strategy More Tesla vs. Edison:

7

Beyond Tesla and Edison: Other Luminaries from the Age of Electricity |  

Broader source: Energy.gov (indexed) [DOE]

Beyond Tesla and Edison: Other Luminaries from the Age of Beyond Tesla and Edison: Other Luminaries from the Age of Electricity Beyond Tesla and Edison: Other Luminaries from the Age of Electricity November 25, 2013 - 1:30pm Addthis Electricity pioneer Charles Proteus Steinmetz (center in light-colored suit) poses with Albert Einstein (immediate left) and other inventors at the RCA Brunswick, New Jersey, wireless station in 1921. | Photo courtesy of Franklin Township Public Library Archive. Electricity pioneer Charles Proteus Steinmetz (center in light-colored suit) poses with Albert Einstein (immediate left) and other inventors at the RCA Brunswick, New Jersey, wireless station in 1921. | Photo courtesy of Franklin Township Public Library Archive. Rob Roberts Rob Roberts Director of Digital Strategy More Tesla vs. Edison:

8

Data:95c46391-13dd-4d17-9534-7b547a7e4397 | Open Energy Information  

Open Energy Info (EERE)

Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to...

9

Data:2f76408d-5e25-40c1-b703-d0f2e9d2a46b | Open Energy Information  

Open Energy Info (EERE)

Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to...

10

Data:A55b88b8-16f4-4a41-8e5e-e4e6ee726743 | Open Energy Information  

Open Energy Info (EERE)

Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to...

11

Lamp Divisions  

Office of Legacy Management (LM)

--- --- /A;; i :' r%i;in~house ilEc;' i:Z3:~cra:ion Lamp Divisions , _.. (I +i. 0 :,,,rg. . I . . -= i?e p/q! qe)-' &se pw E.rcale?l iev, Je!sey 07m March 20, 1 gs? ::r . J. A. Jones I ti. 5. Muclear Regulatory Commission .> = ..- haterials Licensing Branch -s - ,.I, - - Division of Fuel Cycle and hateri al Safety LY. , $2 - _ . ' -' . 3 _- - Yeshington, C. C. 2@555 - :_ :--, =-- -- .-?J -.: y...., : :- 7 Dear Mr. Jones : y-- --, ? . *I 2=15 2 r; X -P The following is our final report of the decontamination efZor?s takz in our Bui Iding 7 basement and wi 11 also serve to update our report i& November 12, 1980. As stated in NRC' s report of December 22, 1983, two closeout inspect ions were conducted by your King of Prussia off i ce on November 21 and December 2,

12

Assessing the Risk of Mercury in Drinking Water after UV Lamp Breaks Page 1 Assessing the Risk of Mercury in Drinking Water after UV Lamp Breaks  

E-Print Network [OSTI]

Assessing the Risk of Mercury in Drinking Water after UV Lamp Breaks Page 1 Assessing the Risk of Mercury in Drinking Water after UV Lamp Breaks Heidi Borchers University of New Hampshire, Environmental Ultraviolet (UV) lamps generate ultraviolet light through the vaporization of elemental mercury, by using

13

Turning on LAMP  

ScienceCinema (OSTI)

Christoph Bostedt, a senior staff scientist at SLAC's Linac Coherent Light Source X-ray laser, provides a sneak peek of a powerful new instrument, called LAMP, that is now available for experiments that probe the atomic and molecular realm. LAMP replaces and updates the first instrument at LCLS, dubbed CAMP, which will be installed at an X-ray laser in Germany.

Bostedt, Christoph

2014-07-16T23:59:59.000Z

14

Turning on LAMP  

SciTech Connect (OSTI)

Christoph Bostedt, a senior staff scientist at SLAC's Linac Coherent Light Source X-ray laser, provides a sneak peek of a powerful new instrument, called LAMP, that is now available for experiments that probe the atomic and molecular realm. LAMP replaces and updates the first instrument at LCLS, dubbed CAMP, which will be installed at an X-ray laser in Germany.

Bostedt, Christoph

2014-06-30T23:59:59.000Z

15

Fluorescent Tube Lamps  

Broader source: Energy.gov [DOE]

FEMP temporarily suspended its energy efficiency requirements for fluorescent tube lamps as it evaluates the market impact of the pending 2012 minimum efficiency standards for fluorescent lamps. The program will issue updated energy efficiency requirements when the market distribution of this product category stabilizes and when doing so has the potential to result in significant Federal energy savings.

16

Magnetic fluorescent lamp  

DOE Patents [OSTI]

The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly is enhanced by providing means for establishing a magnetic field with lines of force along the path of electron flow through the bulb of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

Berman, S.M.; Richardson R.W.

1983-12-29T23:59:59.000Z

17

Energy-efficient incandescent lamp: Final report  

E-Print Network [OSTI]

of Energy Conserving Incandescent Lamps", J . Brett, R.July 1981. "Filaments for Incandescent Lamps with Radiation20-22 "Energy Saving Incandescent Lamps with Infrared

Verderber, R.

2010-01-01T23:59:59.000Z

18

Retail Replacement Lamps  

Broader source: Energy.gov [DOE]

Annual CALiPER testing of A19, G25, candelabra, night light, MR16/PAR16, PAR20, and PAR30 replacement lamps – purchased directly from store shelves – offers insights on performance trends from year to year. The report findings offer valuable insights for manufacturers and retailers alike.

19

LED MR16 Lamps  

Broader source: Energy.gov [DOE]

The following CALiPER report provides detailed analysis of LED MR16 lamp performance, covering basic performance characteristics as well as subjective evaluation of beam, shadow, and color quality. Pending reports will offer analysis on performance attributes that are not captured by LM-79 testing. These reports are intended to educate the industry on market trends, potential issues, and important areas for improvement.

20

LED PAR38 Lamps  

Broader source: Energy.gov [DOE]

The following CALiPER reports provide detailed analysis of LED PAR38 lamp performance, covering basic performance characteristics as well as subjective evaluation of beam, shadow, and color quality. Pending reports will offer analysis on flicker, dimming and power quality characteristics; stress testing; and lumen and chromaticity maintenance. These reports are intended to educate the industry on market trends, potential issues, and important areas for improvement.

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Max Tech and Beyond: Fluorescent Lamps  

E-Print Network [OSTI]

Fluorescent Lamps and Incandescent Reflector Lamps; Finalmany end- use applications. Incandescent Outdoor Stationaryof color compared with the incandescent reference source is

Scholand, Michael

2012-01-01T23:59:59.000Z

22

Energy Cost Calculator for Compact Fluorescent Lamps | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

project. Modify the default values to suit your project requirements. Existing incandescent lamp wattage Watts Incandescent lamp cost dollars Incandescent lamp life 1000 hours...

23

Health Implications of New Lamp Technology Progress with Lamp Safety  

E-Print Network [OSTI]

: ­ ACGIH Threshold Limit Values, UV, lasers, etc. ­ ANSI Z136.1 for lasers with MPEs 0.1 ps -30 ks ­ ANSI RP 27.1 to ANSI RP 27.3 Lamp Safety · Internationally: ­ International Commission on Non

California at Davis, University of

24

Capacitive sensing with a fluorescent lamp  

E-Print Network [OSTI]

This work presents a modified fluorescent lamp that can be used as a capacitive sensing system. The lamp sensor measures changes in the electric fields emitted from the fluorescent bulbs in order to deduce the presence and ...

Cooley, John Jacob

2007-01-01T23:59:59.000Z

25

Integrated starting and running amalgam assembly for an electrodeless fluorescent lamp  

DOE Patents [OSTI]

An integrated starting and running amalgam assembly for an electrodeless SEF fluorescent lamp includes a wire mesh amalgam support constructed to jointly optimize positions of a starting amalgam and a running amalgam in the lamp, thereby optimizing mercury vapor pressure in the lamp during both starting and steady-state operation in order to rapidly achieve and maintain high light output. The wire mesh amalgam support is constructed to support the starting amalgam toward one end thereof and the running amalgam toward the other end thereof, and the wire mesh is rolled for friction-fitting within the exhaust tube of the lamp. The positions of the starting and running amalgams on the wire mesh are jointly optimized such that high light output is achieved quickly and maintained, while avoiding any significant reduction in light output between starting and running operation.

Borowiec, Joseph Christopher (Schenectady, NY); Cocoma, John Paul (Clifton Park, NY); Roberts, Victor David (Burnt Hills, NY)

1998-01-01T23:59:59.000Z

26

LED Linear Lamps and Troffer Lighting  

Broader source: Energy.gov [DOE]

The CALiPER program performed a series of investigations on linear LED lamps. Each report in the series covers the performance of up to 31 linear LED lamps, which were purchased in late 2012 or 2013. The first report focuses on bare lamp performance of LED T8 replacement lamps and subsequent reports examine performance in various troffers, as well as cost-effectiveness. There is also a concise guidance document that describes the findings of the Series 21 studies and provides practical advice to manufacturers, specifiers, and consumers (Report 21.4: Summary of Linear (T8) LED Lamp Testing , 5 pages, June 2014).

27

Max Tech and Beyond: Fluorescent Lamps  

E-Print Network [OSTI]

varies by watts of power per foot of electrical arc in theFoot Linear Fluorescent Lamps Efficacy Life Lumens Type Base Power

Scholand, Michael

2012-01-01T23:59:59.000Z

28

Covered Product Category: Compact Fluorescent Lamps  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including compact fluorescent lamps (CFLs), which are an ENERGY STAR-qualified product category.

29

Energy saving controller for fluorescent lamps.  

E-Print Network [OSTI]

??Although fluorescent lamp is a very efficient lighting device in daily life, still the high harmonic distortion and low power factor cause unnecessary energy consumption.… (more)

Cheong, Zhi Xiong

2010-01-01T23:59:59.000Z

30

LED Replacements for Linear Fluorescent Lamps Webcast  

Broader source: Energy.gov [DOE]

In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting...

31

Energy conservation treatment in Exxon's “the lamp  

Science Journals Connector (OSTI)

In this article, Mary Ann Ferguson-DeThorne examines The Lamp, a publication sponsored by Exxon, to determine when and to what extent Exxon informed The Lamp's audience about an impending energy shortage and possible energy conservation methods, to learn if The Lamp's energy conservation messages reflected Exxon's stated conservation positions, and to compare The Lamp to mass-circulation news magazines in terms of how well it alerted its audience to the impending energy shortage. The crucial period of study here is 1971–1973; prior to the Arab oil boycott and the 1974 Congressional investigation of charges that the large oil companies had contrived shortages to eliminate competition.

Mary Ann Ferguson-DeThorne

1978-01-01T23:59:59.000Z

32

General Service LED Lamps | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

DOE SSL technology fact sheet that compares general service LED light bulbs with incandescent and CFL bulbs. ledgeneral-service-lamps.pdf More Documents & Publications LED...

33

A SPICE Compatible Model of High Intensity Discharge Lamps  

E-Print Network [OSTI]

from the arc's * Corresponding author behavior of HID lamps. This model are derived from the arc-linear resistance of the lamp, is the global specific conductance of the plasma, V is the volume of the plasma, L is the length of plasma and S is the cross section. ~ Vin G1 Lamp Model Ballast v(lamp) i(lamp) Analytical

34

General service incandescent lamp with improved efficiency  

SciTech Connect (OSTI)

A high efficiency general service incandescent lamp is disclosed. The disclosed improved general service incandescent lamp has an outer and an inner envelope. The inner envelope has a relatively small housing containing a halogen gas and a relatively high pressure efficient fill-gas and in which a low voltage filament is spatially disposed therein.

Berlec, I.

1985-06-18T23:59:59.000Z

35

Portable lamp with dynamically controlled lighting distribution  

DOE Patents [OSTI]

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) arranged vertically with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum insures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2001-01-01T23:59:59.000Z

36

LED T8 Replacement Lamps | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

T8 Replacement Lamps LED T8 Replacement Lamps This documents provides an overview of LED T8 replacement lamps and helps define a reasonable minimum performance level for the...

37

Solid-state lamp with integral occupancy sensor  

E-Print Network [OSTI]

Previous work demonstrated a retrofit proximity detector for fluorescent lamps using the lamp's own stray electric fields. This paper extends the retrofit sensor system to a solid-state (LED) lamp. The design and implementation ...

Cooley, John J.

38

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network [OSTI]

as any 1ong-li incandescent lamp or system evaluated in thisEFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGYEFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY

Verderber, Rudy

2013-01-01T23:59:59.000Z

39

DuraLamp USA: Order (2010-CE-0912)  

Broader source: Energy.gov [DOE]

DOE ordered DuraLamp USA, Inc. to pay a $2,500 civil penalty after finding DuraLamp USA had failed to certify that model PAR 30, an incandescent reflector lamp, complies with the applicable energy conservation standards.

40

Tungsten wire for incandescent lamps  

SciTech Connect (OSTI)

Tungsten wire for incandescent lamp filaments must operate at high temperatures and for long times. To meet these requirements, the grain morphology of the wire must be controlled to reduce the propensity for grain boundary sliding. The morphology is a function of the distribution of very small pockets of potassium in the wire and the mechanical processing from ingot to wire. The behavior of the filament is directly related to the grain morphology. This paper describes the mechanism by which the potassium is incorporated into and distributed in the ingot. The elongation and spheroidization of the bubbles during hot rolling and swaging is also examined and related to the grain morphology of wire. Some indications of the relationship between grain morphology and filament behavior are also given.

Walter, J.L.; Briant, C.L. (General Electric Corporate Research and Development, Schenectady, NY (USA))

1990-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Power factor and harmonic distortion characteristics of energy efficient lamps  

SciTech Connect (OSTI)

This paper evaluates the performance of a new class of lamps which are generally classified as the energy-saving lamps. It is shown that, when compared with the incandescent lamps, these lamps indeed consume less real power and have higher relative illumination. However, the energy-saving lamps operate at a low power factor and produce current distortion which are much higher than the distortion produced by the traditional incandescent lamps.

Etezadi-Amoli, M.; Florence, T.

1989-07-01T23:59:59.000Z

42

Cost effectiveness of long life incandescent lamps and energy buttons  

SciTech Connect (OSTI)

Long-life replacement lamps for the incandescent lamp have been evaluated with regard to their cost effectiveness. The replacements include the use of energy buttons that extend lamp life as well as an adaptive fluorescent circline lamp that will fit into existing incandescent lamp sockets. The initial, operating, and replacement costs for one million lumen hours are determined for each lamp system. It is found that the most important component lighting cost is the operating cost. Using lamps that are less efficient or devices that cause lamps to operate less efficiently are not cost-effective. The adaptive fluorescent circline lamp, even at an initial unit cost of $20.00, is the most cost-effective source of illumination compared to the incandescent lamp and lamp systems examined.

Verderber, R.; Morse, O.

1980-04-07T23:59:59.000Z

43

Lamp system for uniform semiconductor wafer heating  

DOE Patents [OSTI]

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

2001-01-01T23:59:59.000Z

44

Compact fluorescent lamp applications in luxury hotels  

SciTech Connect (OSTI)

Over the past several years, consumers, lighting designers, and energy conservationists have paid increasing attention to the special characteristics of compact fluorescent lamps (CFLs). CFLs can typically be used to replace incandescent lamps of three to four times their own wattage, and their color rendering indices (CRIs)-80 to 85-make them virtually indistinguishable from incandescents. The typical 10,0000-hour life of a CFL often makes savings in labor its most desirable feature when compared to a shorter-lived incandescent lamp.

Gilleskie, R.J.

1996-01-01T23:59:59.000Z

45

LED lamp power management system and method  

DOE Patents [OSTI]

An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.

2013-03-19T23:59:59.000Z

46

MagLab - Arc Lamp Tutorial  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

with 2,000 cells to create an arc across a 4-inch (100 millimeter) gap. When suitable electric generators became available in the late 1870s, the practical use of arc lamps began....

47

CALiPER Retail Lamps Study 3  

SciTech Connect (OSTI)

The CALiPER program first began investigating LED lamps sold at retail stores in 2010, purchasing 33 products from eight retailers and covering six product categories. The findings revealed a fragmented marketplace, with large disparities in performance of different products, accuracy of manufacturer claims, and offerings from different retail outlets. Although there were some good products, looking back many would not be considered viable competitors to other available options, with too little lumen output, not high enough efficacy, or poor color quality. CALiPER took another look in late 2011purchasing 38 products of five different types from nine retailers and the improvement was marked. Performance was up; retailer claims were more accurate; and the price per lumen and price per unit efficacy were down, although the price per product had not changed much. Nonetheless, there was still plenty of room for improvement, with the performance of LED lamps not yet reaching that of well-established classes of conventional lamps (e.g., 75 W incandescent A19 lamps). Since the second retail lamp study was published in early 2012, there has been substantial progress in all aspects of LED lamps available from retailers. To document this progress, CALiPER again purchased a sample of lamps from retail stores 46 products in total, focusing on A19, PAR30, and MR16 lamps but instead of a random sample, sought to select products to answer specific hypotheses about performance. These hypotheses focused on expanding ranges of LED equivalency, the accuracy of lifetime claims, efficacy and price trends, as well as changes to product designs. Among other results, key findings include: There are now very good LED options to compete with 60 W, 75 W, and 100 W incandescent A19 lamps, and 75 W halogen PAR30 lamps. MR16 lamps have shown less progress, but there are now acceptable alternatives to 35 W, 12 V halogen MR16 lamps and 50 W, 120 V halogen MR16 lamps for some applications. Other uses, such as in enclosed luminaires, may require more development. At the same price point, lamps purchased in 2013 tended to have higher output and slightly higher efficacy than in 2011 or 2010. Over 30% of the products purchased in 2013 exceeded the maximum efficacy measured in 2011 (71 lm/W), with the most efficacious product measured at 105 lm/W. There appears to be increasing consistency in color quality, with a vast majority of products having a CCT of 2700 K or 3000 K and a CRI between 80 and 85. There were also fewer poor performing products tested and more high-performing products available in 2013 than in previous years. The accuracy of equivalency and performance claims was better than in 2011, but remains a concern, with 43% of tested products failing to completely meet their equivalency claim and 20% of products failing to match the manufacturer’s performance data. Although progress has been substantial, on average LED lamps remain more expensive than other energy efficiency lighting technologies -- although some aspects can be superior. Although not universal to all product lines or all product types, the issue of insufficient lumen output from LED lamps is waning. Thus, manufacturers can focus on other issues, such as reducing cost, improving electrical/dimmer compatibility, eliminating flicker, or improving color quality. While these issues are not inherent to all products, they remain a concern for the broader market.

Royer, Michael P.; Beeson, Tracy A.

2014-02-01T23:59:59.000Z

48

Building Technologies Office: Fluorescent and Incandescent Lamps Public  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Fluorescent and Fluorescent and Incandescent Lamps Public Meeting to someone by E-mail Share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Facebook Tweet about Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Twitter Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Google Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Delicious Rank Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Digg Find More places to share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on AddThis.com... About Standards & Test Procedures Implementation, Certification & Enforcement

49

Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps.  

SciTech Connect (OSTI)

To date, all three reports in the retail lamps series have focused on basic performance parameters, such as lumen output, efficacy, and color quality. This report goes a step further, examining the photoelectric characteristics (i.e., dimming and flicker) of a subset of lamps from CALiPER Retails Lamps Study 3. Specifically, this report focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers. The results demonstrate notable variation across the various lamps, but little variation between the four dimmers. Overall, the LED lamps: ~tended to have higher relative light output compared to the incandescent and halogen benchmark at the same dimmer output signal (RMS voltage). The lamps’ dimming curves (i.e., the relationship between control signal and relative light output) ranged from linear to very similar to the square-law curve typical of an incandescent lamp. ~generally exhibited symmetrical behavior—the same dimming curve—when measured proceeding from maximum to minimum or minimum to maximum control signal. ~mostly dimmed below 10% of full light output, with some exceptions for specific lamp and dimmer combinations ~exhibited a range of flicker characteristics, with many comparing favorably to the level typical of a magnetically-ballasted fluorescent lamp through at least a majority of the dimming range. ~ always exceeded the relative (normalized) efficacy over the dimming range of the benchmark lamps, which rapidly decline in efficacy when they are dimmed. This report generally does not attempt to rank the performance of one product compared to another, but instead focuses on the collective performance of the group versus conventional incandescent or halogen lamps, the performance of which is likely to be the baseline for a majority of consumers. Undoubtedly, some LED lamps perform better—or more similar to conventional lamps—than others. Some perform desirably for one characteristic, but not others. Consumers (and specifiers) may have a hard time distinguishing better-performing lamps from one another; at this time, physical experimentation is likely the best evaluation tool.

Royer, Michael P.; Poplawski, Michael E.; Brown, Charles C.

2014-12-14T23:59:59.000Z

50

Optical monitor for water vapor concentration  

DOE Patents [OSTI]

A system for measuring and monitoring water vapor concentration in a sample uses as a light source an argon discharge lamp, which inherently emits light with a spectral line that is close to a water vapor absorption line. In a preferred embodiment, the argon line is split by a magnetic field parallel to the direction of light propagation from the lamp into sets of components of downshifted and upshifted frequencies of approximately 1575 Gauss. The downshifted components are centered on a water vapor absorption line and are thus readily absorbed by water vapor in the sample; the upshifted components are moved away from that absorption line and are minimally absorbed. A polarization modulator alternately selects the upshifted components or downshifted components and passes the selected components to the sample. After transmission through the sample, the transmitted intensity of a component of the argon line varies as a result of absorption by the water vapor. The system then determines the concentration of water vapor in the sample based on differences in the transmitted intensity between the two sets of components. In alternative embodiments alternate selection of sets of components is achieved by selectively reversing the polarity of the magnetic field or by selectively supplying the magnetic field to the emitting plasma. 5 figs.

Kebabian, P.

1998-06-02T23:59:59.000Z

51

Optical monitor for water vapor concentration  

DOE Patents [OSTI]

A system for measuring and monitoring water vapor concentration in a sample uses as a light source an argon discharge lamp, which inherently emits light with a spectral line that is close to a water vapor absorption line. In a preferred embodiment, the argon line is split by a magnetic field parallel to the direction of light propagation from the lamp into sets of components of downshifted and upshifted frequencies of approximately 1575 Gauss. The downshifted components are centered on a water vapor absorption line and are thus readily absorbed by water vapor in the sample; the upshifted components are moved away from that absorption line and are minimally absorbed. A polarization modulator alternately selects the upshifted components or downshifted components and passes the selected components to the sample. After transmission through the sample, the transmitted intensity of a component of the argon line varies as a result of absorption by the water vapor. The system then determines the concentration of water vapor in the sample based on differences in the transmitted intensity between the two sets of components. In alternative embodiments alternate selection of sets of components is achieved by selectively reversing the polarity of the magnetic field or by selectively supplying the magnetic field to the emitting plasma.

Kebabian, Paul (Acton, MA)

1998-01-01T23:59:59.000Z

52

Energy Cost Calculator for Compact Fluorescent Lamps | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Compact Fluorescent Lamps Compact Fluorescent Lamps Energy Cost Calculator for Compact Fluorescent Lamps October 8, 2013 - 2:18pm Addthis This tool calculates the payback period for your calc retrofit project. Modify the default values to suit your project requirements. Existing incandescent lamp wattage Watts Incandescent lamp cost dollars Incandescent lamp life 1000 hours calc wattage Watts calc cost dollars calc life (6000 hours for moderate use, 10000 hours for high use) 8000 hours Number of lamps in retrofit project Hours operating per week hours Average cost of electricity 0.06 $/kWh Relamper labor costs $/hr Time taken to retrofit all lamps in this project min Time taken to relamp one lamp min Type of Relamping Practiced: Group Relamping: Calculate Simple Payback Period months

53

Comparison of technologies for new energy-efficient lamps  

SciTech Connect (OSTI)

Energy-efficient light bulbs are being developed to replace the incandescent lamp where they can satisfy the design criteria and be used in sockets that have long hours of annual use. The four technologies discussed here include the compact fluorescent lamp, coated-filament lamp, electrodeless fluorescent lamp, and compact high-intensity discharge lamp. The systems demonstrate efficacy improvements of two to four times that of their incandescent counterparts. These new lamps have required considerable advances in lamp technology. They offer the potential for achieving efficacies close to 80 lumens per watt. These new lamps will reduce the energy used annually by incandescent lamps (190 BkWh) by more than 50% in the 1990s, at which times they will be commonly employed.

Verderber, R.R.; Rubinstein, F.R.

1983-06-01T23:59:59.000Z

54

Comparison of technologies for new energy-efficient lamps  

SciTech Connect (OSTI)

Energy-efficient light bulbs are being developed to replace the incandescent lamp where they can satisfy the design criteria and be used in sockets that have long hours of annual use. The four technologies discussed include the compact fluorescent lamp, coated-filament lamp, electrodeless fluorescent lamp, and compact high-intensity discharge lamp. The systems demonstrate efficacy improvements of two to four times that of their incandescent counterparts. These new lamps have required considerable advances in lamp technology. They offer the potential for achieving efficacies close to 80 lm/W. These new lamps will reduce the energy used annually by incandescent lamps (190 billion kWh) by more than 50 percent in the 1990's, at which times they will be commonly employed.

Verderber, R.R.; Rubinstein, F.M.

1984-09-01T23:59:59.000Z

55

Laboratory Evaluation of LED T8 Replacement Lamp Products  

SciTech Connect (OSTI)

A report on a lab setting analysis involving LED lamps intended to directly replace T8 fluorescent lamps (4') showing light output, power, and economic comparisons with other fluorescent options.

Richman, Eric E.; Kinzey, Bruce R.; Miller, Naomi J.

2011-05-23T23:59:59.000Z

56

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network [OSTI]

formation of the electric discharge arc and the metals emitdefined as electric discharge lamps in which the arc tubelamp - an electric discharge lamp in which the arc tube wall

Scholand, Michael

2012-01-01T23:59:59.000Z

57

Text-Alternative Version: LED Replacements for Linear Fluorescent Lamps  

Broader source: Energy.gov [DOE]

Below is the text-alternative version of the "LED Replacements for Linear Fluorescent Lamps" webcast, held June 20, 2011.

58

Medium Base Compact Fluorescent Lamps | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Templates for Reporting Test Results mediumbasecfltestreporttemplatev1.1.xlsx More Documents & Publications Fluorescent Lamp Ballasts Showerheads Beverage Vending Machines...

59

Lighting Group: Sources and Ballasts: LED Reflector Lamp  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

LED Reflector Lamp LED Reflector Lamp LED Reflector Lamp Objective LED reflector lamp The goal of this project is to develop a revolutionary new reflector lamp which offers many advantages over current incandescent reflector lamps, including: three times greater efficiency ten times the rated life greater optical and performance properties use of light emitting diodes (LEDs) to generate the light. Although LEDs have been commercially available since the late 1960Â’s, recent dramatic improvements in LED technology have led to white light devices with efficiencies that meet or exceed those of a standard incandescent lamp. This project will build upon these improvements to develop a new type of source for focusing light. Contact Information For more information on this project, please contact:

60

LED lamp color control system and method  

SciTech Connect (OSTI)

An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A.M.

2013-02-05T23:59:59.000Z

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Fluorescent ballast and lamp disposal issues  

SciTech Connect (OSTI)

All around the world, governments, utility companies, and private businesses are attempting to reduce the amount of energy consumed. In the US alone, new economic strategies and programs are being created to facilitate this process. For instance, the recent enactment of the National Energy Policy Act, the Environmental Protection Agency`s (EPA) Green Lights Program, and a surge of utility involvement in Demand Side Management (DSM) Commercial/Industrial Direct Install and Rebate Programs. Many of these problems target commercial/industrial lighting system retrofits as one of the most cost effective avenues for reducing the consumption of energy. Due to this trend, hundreds of millions of lighting ballasts and lamps are being discarded. The benefits of these programs result in enormous reductions in fossil fuels (and subsequent carbon dioxide, sulfur dioxide, and nitrogen oxide emissions) required to generate the displaced electricity. Throughout the US, however, there is an increasing concern for the environmental impacts surrounding the accelerated disposal of both lighting ballasts and lamps. Regulations initially established were for a one by one, retirement (failure) process rather than promoted obsolescence and forced retirement of lamp groups or entire systems (truckloads of old technologies). Recognizing this trend and the potential negative environmental effects, federal, state, and local regulators are reevaluating the impacts and are being asked to promulgate policies to specifically address this situation.

Leishman, D.L. [Alta Resource Management Services, Inc., Springfield, MA (United States)

1996-12-01T23:59:59.000Z

62

Influence of gas composition on wafer temperature in a tungsten chemical vapor deposition reactor: Experimental measurements, model  

E-Print Network [OSTI]

Influence of gas composition on wafer temperature in a tungsten chemical vapor deposition reactor-wafer, lamp-heated chemical vapor deposition system were used to study the wafer temperature response to gas composition. A physically based simulation procedure for the process gas and wafer temperature was developed

Rubloff, Gary W.

63

RF driven sulfur lamp having driving electrodes arranged to cool the lamp  

DOE Patents [OSTI]

A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.

Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.

1998-10-20T23:59:59.000Z

64

The National Energy Policy Act and lamp replacement options  

SciTech Connect (OSTI)

The National Policy Act of 1992 involves the creation of energy efficiency standards for a wide range of products including fluorescent and incandescent lamps. Minimum efficacy (lumens per watt) and color rendering index (CRI) standards are mandated for the popular fluorescent lamps: four-foot medium bi-pin, two-foot U-bent, eight-foot slimline and eight-foot high output. Minimum efficacies are mandated for specific incandescent R and PAR reflector lamps. These standards will affect selected colors and designs of fluorescent lamps, the most significant being the standard lamps in the cool white and warm white colors. The incandescent reflector lamps will include the R-30, R-40, PAR-38 lamps above 40 watts, excluding the halogen types. These efficiency and color rendering standards will require end-users and specifiers to select replacement fluorescent lamps from a range of performance characteristics (lumen output, efficacy, CRI and price). The choice of replacement for the R and PAR incandescent lamps will include the halogen designs and compact fluorescent designs. In this paper, replacement options will be analyzed and discussed and the effect of these options on the performance of the lighting system will be explored in detail.

Ryerson, C.

1995-06-01T23:59:59.000Z

65

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network [OSTI]

of color compared with the incandescent reference source isin this report. Standard Incandescent Halogen Low-Pressure:value equivalent to an incandescent filament lamp. Taking

Scholand, Michael

2012-01-01T23:59:59.000Z

66

Lamp for generating high power ultraviolet radiation  

DOE Patents [OSTI]

The apparatus is a gas filled ultraviolet generating lamp for use as a liquid purifier. The lamp is powred by high voltage AC, but has no metallic electrodes within or in contact with the gas enclosure which is constructed as two concentric quartz cylinders sealed together at their ends with the gas fill between the cylinders. Cooling liquid is pumped through the volume inside the inner quartz cylinder where an electrically conductive pipe spaced from the inner cylinder is used to supply the cooling liquid and act as the high voltage electrode. The gas enclosure is enclosed within but spaced from a metal housing which is connected to operate as the ground electrode of the circuit and through which the treated fluid flows. Thus, the electrical circuit is from the central pipe, and through the cooling liquid, the gas enclosure, the treated liquid on the outside of the outer quartz cylinder, and to the housing. The high voltage electrode is electrically isolated from the source of cooling liquid by a length of insulated hose which also supplies the cooling liquid.

Morgan, Gary L. (Elkridge, MD); Potter, James M. (Los Alamos, NM)

2001-01-01T23:59:59.000Z

67

DEFINING THE EFFECTIVENESS OF UV LAMPS  

Office of Scientific and Technical Information (OSTI)

ARTI-21CR/610-40030-01 ARTI-21CR/610-40030-01 DEFINING THE EFFECTIVENESS OF UV LAMPS INSTALLED IN CIRCULATING AIR DUCTWORK Final Report Date Published - November 2002 Douglas VanOsdell and Karin Foarde RTI P.O. Box 12194 Research Triangle Park, NC 27709-2194 Prepared for the AIR-CONDITIONING AND REFRIGERATION TECHNOLOGY INSTITUTE 4100 N. Fairfax Drive, Suite 200, Arlington, Virginia 22203 Distribution A - Approved for public release; further dissemination unlimited. DISCLAIMER This report was prepared as an account of work sponsored by the Air-Conditioning and Refrigeration Technology Institute (ARTI) under its "HVAC&R Research for the 21 st Century" (21-CR) program. Neither ARTI, the financial supporters of the 21-CR program, or any agency

68

Application Summary Report 22: LED MR16 Lamps  

SciTech Connect (OSTI)

This report analyzes the independently tested photometric performance of 27 LED MR16 lamps. It describes initial performance based on light output, efficacy, distribution, color quality, electrical characteristics, and form factor, with comparisons to a selection of benchmark halogen MR16s and ENERGY STAR qualification thresholds. Three types of products were targeted. First, CALiPER sought 3000 K lamps with the highest rated lumen output (i.e., at least 500 lm) or a claim of equivalency to a 50 W halogen MR16 or higher. The test results indicate that while the initial performance of LED MR16s has improved across the board, market-available products still do not produce the lumen output and center beam intensity of typical 50 W halogen MR16 lamps. In fact, most of the 18 lamps in this category had lower lumen output and center beam intensity than a typical 35 W halogen MR16 lamp. Second, CALiPER sought lamps with a CRI of 90 or greater. Only four manufacturers were identified with a product in this category. CALiPER testing confirmed the performance of these lamps, which are a good option for applications where high color fidelity is needed. A vast majority of the LED MR16 lamps have a CRI in the low 80s; this is generally acceptable for ambient lighting, but may not always be acceptable for focal lighting. For typical LED packages, there is a fundamental tradeoff between CRI and efficacy, but the lamps in the high-CRI group in this report still offer comparable performance to the rest of the Series 22 products in other performance areas. Finally, CALiPER sought lamps with a narrow distribution, denoted as a beam angle less than 15°. Five such lamps were purchased. Notably, no lamp was identified as having high lumen output (500 lumens or greater), high CRI (90 or greater), a narrow distribution (15° or less), and an efficacy greater than 60 lm/W. This would be an important achievement for LED MR16s especially if output could reach approximately 700 800 lumens, or the approximate equivalent of a 50 W halogen MR16 lamp. Many factors beyond photometric performance should be considered during specification. For example, performance over time, transformer and dimmer compatibility, and total system performance are all critical to a successful installation. Subsequent CALiPER reports will investigate more complex issues.

Royer, Michael P.

2014-07-23T23:59:59.000Z

69

Highly Efficient Small Form Factor LED Retrofit Lamp  

SciTech Connect (OSTI)

This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent power quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40{sup o} and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.

Steven Allen; Fred Palmer; Ming Li

2011-09-11T23:59:59.000Z

70

Maintaining optimum fluorescent lamp performance under elevated temperature conditions  

SciTech Connect (OSTI)

This paper describes a new technique for optimizing fluorescent lamp performance under elevated temperature conditions. This approach uses a thermo-electric Peltier device to produce a localized cold spot temperature of approximately 40/sup 0/C, allowing the lamps to maintain maximum light output and efficacy independent of prevailing ambient temperatures inside a luminaire. Experimental data show that a 20% increase in light output and a 10% increase in efficacy over typical lamp performance in a warm fixture environment can be obtained using this device. Only 0.25 watts must be supplied to the Peltier device to produce these results.

Siminovitch, M.J.; Rubinstein, F.M.; Clark, T.A.; Verderber, R.R.

1986-04-01T23:59:59.000Z

71

Covered Product Category: Compact Fluorescent Lamps | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps October 7, 2013 - 10:48am Addthis ENERGY STAR Qualified Products Federal Energy Management Program (FEMP) provides acquisition guidance across a variety of product categories, including compact fluorescent lamps (CFLs), which are an ENERGY STAR-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR.

72

Information Resources: LED Replacements for Linear Fluorescent Lamps  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Replacements for Linear Fluorescent Lamps Webcast Replacements for Linear Fluorescent Lamps Webcast In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting Facts-listed products as well as products evaluated in the latest CALiPER reports. Eric Richman, also of PNNL, reported on a recently completed GATEWAY demonstration project, in which LED and fluorescent lamps were installed in a variety of recessed troffer luminaires for comparison in an office environment. The presentation concluded with a discussion of specifications listed in a newly updated technology fact sheet. View presentation slides View the text-alternative version View the webcast (WMV 16 MB) Download Windows Media Player

73

Burst Radio-Frequency Excited Pulsed Hollow-Cathode Lamp  

Science Journals Connector (OSTI)

Transient emission characteristics of a hollow-cathode lamp driven by a pulsed current in combination with a radio-frequency burst signal are described. The radio-frequency field...

Araki, Tsutomu; Walters, John P; Minami, Shigeo

1980-01-01T23:59:59.000Z

74

DOE Publishes Long-Term Testing Investigation of Retail Lamps  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy's CALiPER program has released another special report on LED lamps that are available through the retail marketplace and targeted toward general consumers. CALiPER...

75

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network [OSTI]

38 TWh, 10% of which was for incandescent lighting (Fig. 3).The electricity consumed in incandescent lighting can be300 and 400 million incandescent lamps in the country. Let

Gadgil, A.J.

2008-01-01T23:59:59.000Z

76

Optimized Magnetic Components Improve Efficiency of Compact Fluorescent Lamps  

E-Print Network [OSTI]

xtures (designed for incandescent bulbs) has allowed residential and small commercial electric customers of incandescent lamps and last 10 times longer [1]. High-frequency electronic ballasts are used to power CFLs

77

DOE Publishes New CALiPER Report on Retail Lamps  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy's CALiPER program has released a special report on LED lamps available through the retail marketplace and targeted toward general consumers. While previous reports in...

78

Magnetic fluorescent lamp having reduced ultraviolet self-absorption  

DOE Patents [OSTI]

The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly (10) is enhanced by providing means (30) for establishing a magnetic field with lines of force along the path of electron flow through the bulb (12) of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

Berman, Samuel M. (San Francisco, CA); Richardson, Robert W. (Pelham, NY)

1985-01-01T23:59:59.000Z

79

Perceptions of compact fluorescent lamps in the residential market  

SciTech Connect (OSTI)

Compact fluorescent lamps offer significant energy savings over other forms of residential lighting and last up to 10 times longer than conventional incandescent bulbs. In order to better understand existing barriers to acceptance and future opportunities for growth of compact fluorescent lighting in the residential retrofit sector, a three stage research project was designed and conducted by MACRO Consulting, Inc. Assessment of whether or not the benefits of compact fluorescent lamps are sufficient to overcome price resistance was one of the major purposes of this project. Residential customers were interviewed in focus group sessions to help determine key issues and motivating forces in the lighting/energy saving/cost saving equation. Residential customers in 5 major market areas were contacted by telephone, and data about their awareness, knowledge and use of compact fluorescent lighting were collected. These customers also participated in an attribute rating exercise in which compact fluorescent lamps were compared with fluorescent tubes and incandescent bulbs on a series of product attributes. A price elasticity exercise was also conducted. Teleconferences with retailers of compact fluorescent lamps were conducted in order to explore their knowledge of and attitudes towards compact fluorescent lamps. Customers agree that energy savings and longer life are both positive attributes for residential lighting products, but they are not yet ready to make the switch away from inexpensive, versatile and readily available incandescent bulbs to compact fluorescent lamps. Compact fluorescent lamps are rated poorly (even by satisfied'' users) on each of seven positive attributes of home lighting. Major barriers to increased use of compact fluorescent lamps include price, convenience, and performance. Prices above $10 are considered outrageous''. Product improvements are needed for appearance, light output and versatility.

Weiner, J.; Campbell, C.J. (Macro Consulting, Inc., Mountain View, CA (United States))

1992-07-01T23:59:59.000Z

80

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

DOE Patents [OSTI]

A novel design is described for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment. 9 figs.

Siminovitch, M.

1998-02-10T23:59:59.000Z

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

E-Print Network [OSTI]

standard for linear fluorescent lamps Length (mm) Minimum efficacy (lm/W) Efficacy for energy conservation

Lin, Jiang

2002-01-01T23:59:59.000Z

82

Calibrated vapor generator source  

DOE Patents [OSTI]

A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet. 10 figs.

Davies, J.P.; Larson, R.A.; Goodrich, L.D.; Hall, H.J.; Stoddard, B.D.; Davis, S.G.; Kaser, T.G.; Conrad, F.J.

1995-09-26T23:59:59.000Z

83

ARM Water Vapor IOP  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

ARM Water Vapor IOP The SGP CART site will host the third ARM water vapor IOP on September 18-October 8, 2000. The CART site is home to a powerful array of instruments capable of...

84

2014-12-30 Issuance: Energy Conservation Standard for General Service Fluorescent Lamps and Incandescent Reflector Lamps; Final Rule  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register final rule regarding energy conservation standards for general service fluorescent lamps and incandescent reflector lamps, as issued by the Deputy Assistant Secretary for Energy Efficiency on December 30, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

85

Confirmation of the chromosomal localization of human lamp genes and their exclusion as candidate genes for Salla disease  

Science Journals Connector (OSTI)

Salla disease is an inherited lysosomal storage disorder caused by accumulation of free sialic acid in the lysosomes. Lamp genes, lamp A and lamp B (lysosome associated membrane proteins), are the first known ...

Johanna Schleutker; Leena Haataja; Martin Renlund; Lea Puhakka…

1991-11-01T23:59:59.000Z

86

Low-pressure microwave plasma ultraviolet lamp for water purification  

Science Journals Connector (OSTI)

Low-pressure mercury lamps are commonly used for germicidal applications. The germicidal effect is due to the emission of light at 254 nm, which leads to the destruction of the most waterborne bacteria and viruses. The microwave plasma ultraviolet (UV) lamp (MPUVL) is a new technology for generating a high-intensity UV light and that can be also controlled to operate at 185 nm; irradiation is in air at this wavelength produces ozone. The microwave power is injected into a resonant cavity and the surface wave excitation takes place within the cavity through that part of the discharge tube (fused silica) protruding inside it. The MPUVL has many advantages over conventional lamps, which are limited to an output power in the region of 30 W m-1, while MPUVL can deliver any amount of power per unit length and the tube can be of any shape, length or diameter. This paper describes the design of the MPUVL and compares its efficiency with that of conventional lamps through spectral analysis. Other results, which include the effects of temperature and different power inputs, are also discussed.

A I Al-Shamma'a; I Pandithas; J Lucas

2001-01-01T23:59:59.000Z

87

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry Speaker(s): Francis Rubinstein Date: February 14, 2008 - 12:00pm Location: 90-3122 Fluorescent lamp ballasts are subject to DOE appliance standards and rulemaking. But currently, only ballasts for older fluorescent lamp types, such as T-12 lamps are subject to minimum efficacy limits. The majority of fluorescent lamps now being shipped (T-8 and T-5 types) type are operated by ballasts that will not be subject to DOE rule until 2011. The metric used by DOE for characterizing the electrical efficiency of the fluorescent lamp-ballast system is called Ballast Efficacy Factor (BEF). Because BEF is not normalized, it is of limited utility for rulemaking and is useless for procurement. But by normalizing BEF to the total lamp power, I have

88

Solid-State Lighting: LED Replacement Lamps: Current Performance and the  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

LED Replacement Lamps: Current LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® to someone by E-mail Share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Facebook Tweet about Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Twitter Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Google Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Delicious Rank Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Digg Find More places to share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on

89

LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR®  

Broader source: Energy.gov [DOE]

This May 19, 2009 webcast summarized CALiPER's recent benchmark testing of common omnidirectional incandescent lamps (e.g., A-lamps), and provided an update on ENERGY STAR criteria for LED integral...

90

DOE Publishes CALiPER Report on Cost-Effectiveness of Linear (T8) LED Lamps  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy's CALiPER program has released Report 21.3, which is part of a series of investigations on linear LED lamps. Report 21.3 details a set of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38W total power draw) or fluorescent lamps (51W total power draw) over a 10-year study period.

91

Transport phenomena in metal-halide lamps a poly-diagnostic study  

E-Print Network [OSTI]

/ spectroscopie. Subject headings: gas discharges / metal-halide lamps / plasma diagnostics / plasma properties-halide arc lamps . . . . . . . . . . . 7 1.3 Scope of ThesisTransport phenomena in metal-halide lamps a poly-diagnostic study Tanya Nimalasuriya #12;Copyright

Eindhoven, Technische Universiteit

92

Vapor spill monitoring method  

DOE Patents [OSTI]

Method for continuous sampling of liquified natural gas effluent from a spill pipe, vaporizing the cold liquified natural gas, and feeding the vaporized gas into an infrared detector to measure the gas composition. The apparatus utilizes a probe having an inner channel for receiving samples of liquified natural gas and a surrounding water jacket through which warm water is flowed to flash vaporize the liquified natural gas.

Bianchini, Gregory M. (Livermore, CA); McRae, Thomas G. (Livermore, CA)

1985-01-01T23:59:59.000Z

93

DuraLamp USA: Proposed Penalty (2010-CE-0912) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) September 9, 2010 DOE alleged in a Notice of Proposed Civil Penalty that DuraLamp USA, Inc. failed to certify a variety of general service fluorescent lamps as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. DuraLamp USA: Proposed Penalty (2010-CE-0912) More Documents & Publications DuraLamp USA: Order (2010-CE-0912)

94

Energy-efficient compact screw-in fluorescent lamp. Final report  

SciTech Connect (OSTI)

A compact fluorescent lamp has been designed and constructed which can replace an incandescent lamp. The lamp is slightly larger than a standard lamp (8 3/4 in. x 3 1/4 in.), but is designed to fit a majority of portable lamp applications. This version, with a core-coil ballast, results in a system efficacy of 54 lumens per watt, with a light output of more than 1800 lumens. This compares favorably with a 100-watt incandescent (17.5 lumens per watt and 1750 lumens light output). The color temperature of 3000/sup 0/K is compatible with an incandescent lamp (2800/sup 0/K). The color rendition index (CRI) is 84. With a solid-state ballast, the efficacy and light output could be increased by 20% (65 l/w, 2200 lumens) and could provide a direct replacement for a three-way, 150-watt incandescent lamp (15 l/w, 2200 lumens).

Morton, E.W.

1982-11-01T23:59:59.000Z

95

Sulfur Lamps-The Next Generation of Efficient Light?  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

5 5 Sulfur Lamps-The Next Generation of Efficient Light? The figure above is a schematic of the system installed at the National Air and Space Museum and the DOE headquarters in Washington, D.C., Light from the sulfur lamp is focused by a parabolic reflector so that it enters the light pipe within a small angular cone. Light travels down the pipe, reflecting off the prismatic film (A) that lines the outer acrylic tube. The prismatic film reflects the light through total internal reflection (C), an intrinsically efficient process. Some of the light striking the film (at A) is not reflected and "leaks out" of the pipe walls (B), giving the pipe a glowing appearance. A light ray that travels all the way down the pipe will strike the mirror at the end (D) and return back up the pipe.

96

L Prize Competition Winner 60W Incandesent Replacement Lamp Update  

Broader source: Energy.gov (indexed) [DOE]

Technology Deployment Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International May 23, 2012 Philips Wins First L Prize 2 * August 3, 2011: Philips announced as winner of 60W replacement bulb category * Product distributed thru commercial and retail channels Image courtesy of Philips -...[O]nce an award is made the authorizing Act directs General Services Administration to develop federal purchasing schedules for solid-state lamps that meet or exceed the specifications laid out in the prize category-so long as it is cost effective. I hope the GSA begins this process soon.‖

97

ARM - Water Vapor  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Water Vapor Outreach Home Room News Publications Traditional Knowledge Kiosks Barrow, Alaska Tropical Western Pacific Site Tours Contacts Students Study Hall About ARM Global...

98

ISSUANCE 2014-12-29: Energy Conservation Program: Clarification for Energy Conservation Standards and Test Procedures for Fluorescent Lamp Ballasts  

Broader source: Energy.gov [DOE]

Energy Conservation Program: Clarification for Energy Conservation Standards and Test Procedures for Fluorescent Lamp Ballasts

99

Photovoltaic experiment using light from a solar simulator lamp  

Science Journals Connector (OSTI)

A photovoltaic cellexperiment utilizing the convenience of a solar simulating type lamp is described. The circuit for obtaining the cell characteristic drives an X?Y plotter to graph continuously the characteristics from short circuit current to the open circuit voltage. Calibration methods and their limitation are discussed for estimating the irradiance to determine the light conversion efficiency of the cell. The diode junction nature of the cell is clearly supported by the agreement between experiment and theory. The experiment should be exceptionally suitable for an undergraduate physics laboratory experiment.

R. H. Chow

1980-01-01T23:59:59.000Z

100

Lumen and Chromaticity Maintenance of LED PAR38 Lamps Operated in Steady-State Conditions  

SciTech Connect (OSTI)

The lumen depreciation and color shift of 38 different lamps (32 LED, 2 CFL, 1 ceramic metal halide [CMH], 3 halogen) were monitored in a specially developed automated long-term test apparatus (ALTA2) for nearly 14,000 hours. Five samples of each lamp model were tested, with measurements recorded on a weekly basis. The lamps were operated continuously at a target ambient temperature between 44°C and 45°C.

Royer, Michael P.

2014-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Text-Alternative Version: CALiPER Series 21 on LED Linear Lamps and Troffer Lighting  

Broader source: Energy.gov [DOE]

Following is a text version of a video about CALiPER Application Report Series 21 on LED Linear Lamps and Troffer Lighting.

102

Text-Alternative Version: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR®  

Broader source: Energy.gov [DOE]

Below is the text-alternative version of the LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® webcast.

103

DOE Publishes Special CALiPER Report on Retail Lamps | Department...  

Broader source: Energy.gov (indexed) [DOE]

retail marketplace and targeted toward general consumers. The report follows similar reports published in 2011 and 2012. LED replacement lamps are available through many retail...

104

LED Linear Lamps and Troffer Lighting: CALiPER Report Series 21  

SciTech Connect (OSTI)

Video about CALiPER Report Series 21 on LED Linear Lamps and Troffer Lighting, featuring interviews with Tracy Beeson and Naomi Miller of Pacific Northwest National Laboratory.

Beeson, Tracy; Miller, Naomi

2014-06-17T23:59:59.000Z

105

The effects of supply harmonics on the performance of compact fluorescent lamps  

SciTech Connect (OSTI)

This paper describes a performance evaluation of ten compact fluorescent lighting systems operated with sinusoidal and distorted voltage waveform conditions. The lamps were either provided with an electronic ballast, a magnetic core ballast or a magnetic core ballast with a power factor correction circuit. The test results show that the electrical performance of the compact fluorescent lamps for both sinusoidal and distorted voltage waveform operation is related to the different types of ballast used. The cost of operation of these compact fluorescent lamps was calculated and compared to the cost of a conventional 60 W incandescent lamp.

Arseneau, R.; Ouellette, M.

1993-04-01T23:59:59.000Z

106

EA-1911: Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps  

Broader source: Energy.gov [DOE]

This EA will evaluate the environmental impacts of a proposal to amend energy conservation standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps.

107

J.-A. FLEMING. 2014 On the characteristic curves and surfaces of incandescence lamps (Courbes caractristiques des lampes incandescence) ; Phil. Mag.,  

E-Print Network [OSTI]

80 J.-A. FLEMING. 2014 On the characteristic curves and surfaces of incandescence lamps (Courbes caractéristiques des lampes à incandescence) ; Phil. Mag., 5e série, t. XIX, p. 368; I885. L'auteur étudie les résistance correspondant à la force électromotrice vo à laquelle l'incandescence commence à se produire, et r

Paris-Sud XI, Université de

108

Gasoline vapor recovery  

SciTech Connect (OSTI)

In a gasoline distribution network wherein gasoline is drawn from a gasoline storage tank and pumped into individual vehicles and wherein the gasoline storage tank is refilled periodically from a gasoline tanker truck, a method of recovering liquid gasoline from gasoline vapor that collects in the headspace of the gasoline storage tank as the liquid gasoline is drawn therefrom, said method comprising the steps of: (a) providing a source of inert gas; (b) introducing inert gas into the gasoline storage tank as liquid gasoline is drawn therefrom so that liquid gasoline drawn from the tank is displaced by inert gas and gasoline vapor mixes with the inert gas in the headspace of the tank; (c) collecting the inert gas/gasoline vapor mixture from the headspace of the gasoline storage tank as the tank is refilled from a gasoline tanker truck; (d) cooling the inert gas/gasoline vapor mixture to a temperature sufficient to condense the gasoline vapor in the mixture to liquid gasoline but not sufficient to liquify the inert gas in the mixture; (e) separating the condensed liquid gasoline from the inert gas; and delivering the condensed liquid gasoline to a remote location for subsequent use.

Lievens, G.; Tiberi, T.P.

1993-06-22T23:59:59.000Z

109

Spatial and time-dependent distribution of plasma parameters in the metal-halide arc lamp.  

E-Print Network [OSTI]

Spatial and time-dependent distribution of plasma parameters in the metal-halide arc lamp. A. Khakhaev, L. Luizova, K. Ekimov and A. Soloviev Petrozavodsk State University, Russia The metal-halide arc lamp is an effective light source and its investigation has a long history, but even at present some

Paris-Sud XI, Université de

110

Demonstration Of A Monitoring Lamp To Visualize The Energy Consumption In Houses  

E-Print Network [OSTI]

Demonstration Of A Monitoring Lamp To Visualize The Energy Consumption In Houses Christophe Gisler1://www.unipg.it Abstract. We report on the development of a wireless lamp dedicated to the feedback of energy consumption is a good solution to make people gain awareness of their energy consumption and hence reduce it [1

Paris-Sud XI, Université de

111

Spectral irradiance model for tungsten halogen lamps in 340-850 nm wavelength range  

SciTech Connect (OSTI)

We have developed a physical model for the spectral irradiance of 1 kW tungsten halogen incandescent lamps for the wavelength range 340-850 nm. The model consists of the Planck's radiation law, published values for the emissivity of tungsten, and a residual spectral correction function taking into account unknown factors of the lamp. The correction function was determined by measuring the spectra of a 1000 W, quartz-halogen, tungsten coiled filament (FEL) lamp at different temperatures. The new model was tested with lamps of types FEL and 1000 W, 120 V quartz halogen (DXW). Comparisons with measurements of two national standards laboratories indicate that the model can account for the spectral irradiance values of lamps with an agreement better than 1% throughout the spectral region studied. We further demonstrate that the spectral irradiance of a lamp can be predicted with an expanded uncertainty of 2.6% if the color temperature and illuminance values for the lamp are known with expanded uncertainties of 20 K and 2%, respectively. In addition, it is suggested that the spectral irradiance may be derived from resistance measurements of the filament with lamp on and off.

Ojanen, Maija; Kaerhae, Petri; Ikonen, Erkki

2010-02-10T23:59:59.000Z

112

CALiPER Report 20.3: Robustness of LED PAR38 Lamps  

SciTech Connect (OSTI)

Three samples of 40 of the Series 20 PAR38 lamps underwent multi-stress testing, whereby samples were subjected to increasing levels of simultaneous thermal, humidity, electrical, and vibrational stress. The results do not explicitly predict expected lifetime or reliability, but they can be compared with one another, as well as with benchmark conventional products, to assess the relative robustness of the product designs. On average, the 32 LED lamp models tested were substantially more robust than the conventional benchmark lamps. As with other performance attributes, however, there was great variability in the robustness and design maturity of the LED lamps. Several LED lamp samples failed within the first one or two levels of the ten-level stress plan, while all three samples of some lamp models completed all ten levels. One potential area of improvement is design maturity, given that more than 25% of the lamp models demonstrated a difference in failure level for the three samples that was greater than or equal to the maximum for the benchmarks. At the same time, the fact that nearly 75% of the lamp models exhibited better design maturity than the benchmarks is noteworthy, given the relative stage of development for the technology.

Poplawski, Michael E.; Royer, Michael P.; Brown, Charles C.

2014-12-31T23:59:59.000Z

113

Table lamp with dynamically controlled lighting distribution and uniformly illuminated luminous shade  

DOE Patents [OSTI]

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) or other lamps arranged vertically, i.e. one lamp above the other, with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum ensures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. In a particular configuration, the reflective septum is bowl shaped, with the upper CFL sitting in the bowl, and a luminous shade hanging down from the bowl. The lower CFL provides both task lighting and uniform shade luminance. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. However, other types of lamps, including incandescent, halogen, and LEDs can also be used in the fixture. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2002-01-01T23:59:59.000Z

114

The evolving price of household LED lamps: Recent trends and historical comparisons for the US market  

SciTech Connect (OSTI)

In recent years, household LED light bulbs (LED A lamps) have undergone a dramatic price decline. Since late 2011, we have been collecting data, on a weekly basis, for retail offerings of LED A lamps on the Internet. The resulting data set allows us to track the recent price decline in detail. LED A lamp prices declined roughly exponentially with time in 2011-2014, with decline rates of 28percent to 44percent per year depending on lumen output, and with higher-lumen lamps exhibiting more rapid price declines. By combining the Internet price data with publicly available lamp shipments indices for the US market, it is also possible to correlate LED A lamp prices against cumulative production, yielding an experience curve for LED A lamps. In 2012-2013, LED A lamp prices declined by 20-25percent for each doubling in cumulative shipments. Similar analysis of historical data for other lighting technologies reveals that LED prices have fallen significantly more rapidly with cumulative production than did their technological predecessors, which exhibited a historical decline of 14-15percent per doubling of production.

Gerke, Brian F.; Ngo, Allison T.; Alstone, Andrea L.; Fisseha, Kibret S.

2014-10-14T23:59:59.000Z

115

Performance of "Ultra-High" Efficient Electronic Ballast for HID Lamps  

E-Print Network [OSTI]

. Index Terms--Electronic ballast, HID lamps, resonant inverter, power loss modeling, Silicon Carbide (Si of >95% for the ballast. Diode bridge rectifier EMI filter Resonant Inverter Power Factor Correction 75423, USA Abstract--A new electronic ballast circuit for High Intensity Discharge (HID) lamps

Tolbert, Leon M.

116

Photo-Electric Ionization of Caesium Vapor  

Science Journals Connector (OSTI)

Measurement of photo-electric ionization in gases.—The current from a filament, normally limited by space change, is increased by the presence of positive ions. As shown by Kingdon this effect may be greatly magnified if a small cathode is practically enclosed by the anode so that the ions are imprisoned. This method was used for the detection of photo-electric ionization. Besides possessing extreme sensitivity it is unaffected by photo-electric emission from the electrodes.Photo-electric effect in caesium vapor.—The change in thermionic current with the unresolved radiation from a mercury arc was measured as functions of the applied voltage, filament temperature, and vapor pressure. Then the photo-electric effect as a function of wave-length was studied using a monochromatic illuminator to disperse light from the arc or a Mazda lamp. The ionization per unit flux was found to increase with increasing wave-length to a sharp maximum at the limit 1s=3184A of the principal series, as is required by the Bohr theory. For longer wave-lengths the ionization decreased to about 10 percent at 3400A. Photo-excitation. The simple theory does not admit of ionization by wave-lengths greater than 3184A but the data are in qualitative agreement with the hypothesis that such radiation produces excited atoms which upon collision with other atoms acquire sufficient additional energy to become ionized. Hence, unlike an x-ray limit, the photo-ionization effect for a valence electron is not sharply discontinuous at the true threshold for direct ionization.Photo-ionization photometer and intensitometer. A tube of the type described, with suitable gases for the range of wave-length involved, may be used as a photometer or may be calibrated to measure intensity of radiation directly.

Paul D. Foote and F. L. Mohler

1925-08-01T23:59:59.000Z

117

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

SciTech Connect (OSTI)

Lighting has been one of the fastest growing electric end-uses in China over the last twenty years, with an average annual growth rate of 14%. Fluorescent lighting provides a significant portion of China's lighting need. In 1998, China produced 680 million fluorescent lamps, of which 420 million were linear fluorescent lamps of various diameters (T8 to T12). There are substantial variations both in energy efficiency and lighting performance among locally produced fluorescent lamps. Such variations present a perfect opportunity for policy intervention through efficiency standards to promote the adoption of more efficient fluorescent lamps in China. This paper analyzes China's proposed minimum efficiency standard for fluorescent lamps and presents an assessment of its likely impacts on China's lighting energy consumption and GHG emissions.

Lin, Jiang

2002-04-11T23:59:59.000Z

118

Electrolyte vapor condenser  

DOE Patents [OSTI]

A system is disclosed for removing electrolyte from a fuel cell gas stream. The gas stream containing electrolyte vapor is supercooled utilizing conventional heat exchangers and the thus supercooled gas stream is passed over high surface area passive condensers. The condensed electrolyte is then drained from the condenser and the remainder of the gas stream passed on. The system is particularly useful for electrolytes such as phosphoric acid and molten carbonate, but can be used for other electrolyte cells and simple vapor separation as well. 3 figs.

Sederquist, R.A.; Szydlowski, D.F.; Sawyer, R.D.

1983-02-08T23:59:59.000Z

119

Electrolyte vapor condenser  

DOE Patents [OSTI]

A system is disclosed for removing electrolyte from a fuel cell gas stream. The gas stream containing electrolyte vapor is supercooled utilizing conventional heat exchangers and the thus supercooled gas stream is passed over high surface area passive condensers. The condensed electrolyte is then drained from the condenser and the remainder of the gas stream passed on. The system is particularly useful for electrolytes such as phosphoric acid and molten carbonate, but can be used for other electrolyte cells and simple vapor separation as well.

Sederquist, Richard A. (Newington, CT); Szydlowski, Donald F. (East Hartford, CT); Sawyer, Richard D. (Canton, CT)

1983-01-01T23:59:59.000Z

120

190 IEEE TRANSACTIONS ON PLASMA SCIENCE, VOL. 30, NO. 1, FEBRUARY 2002 Gap Closure in a Cold Metal Halide Lamp  

E-Print Network [OSTI]

lamp has been investigated using a two-dimensional, plasma transport model. Im- ages are presented- charge devices, lighting, plasma applications. METAL halide high-intensity-discharge (HID) lamps op- erate as high-pressure thermal arcs [1]. The cold fills of HID lamps are typically 50­100 torr of a rare

Kushner, Mark

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Organic vapor jet printing system  

SciTech Connect (OSTI)

An organic vapor jet printing system includes a pump for increasing the pressure of an organic flux.

Forrest, Stephen R

2012-10-23T23:59:59.000Z

122

CALiPER Report 21.3: Cost-Effectiveness of Linear (T8) LED Lamps  

SciTech Connect (OSTI)

Meeting performance expectations is important for driving adoption of linear LED lamps, but cost-effectiveness may be an overriding factor in many cases. Linear LED lamps cost more initially than fluorescent lamps, but energy and maintenance savings may mean that the life-cycle cost is lower. This report details a series of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38 W total power draw) or fluorescent lamps (51 W total power draw) over a 10-year study period. Variables included LED system cost ($40, $80, or $120), annual operating hours (2,000 hours or 4,000 hours), LED installation time (15 minutes or 30 minutes), and melded electricity rate ($0.06/kWh, $0.12/kWh, $0.18/kWh, or $0.24/kWh). A full factorial of simulations allows users to interpolate between these values to aid in making rough estimates of economic feasibility for their own projects. In general, while their initial cost premium remains high, linear LED lamps are more likely to be cost-effective when electric utility rates are higher than average and hours of operation are long, and if their installation time is shorter.

Miller, Naomi J.; Perrin, Tess E.; Royer, Michael P.

2014-05-27T23:59:59.000Z

123

Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)  

DOE Patents [OSTI]

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

1999-01-01T23:59:59.000Z

124

Mercury Vapor | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor Mercury Vapor Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Mercury Vapor Details Activities (23) Areas (23) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Lab Analysis Techniques Exploration Sub Group: Fluid Lab Analysis Parent Exploration Technique: Fluid Lab Analysis Information Provided by Technique Lithology: Stratigraphic/Structural: Anomalously high concentrations can indicate high permeability or conduit for fluid flow Hydrological: Field wide soil sampling can generate a geometrical approximation of fluid circulation Thermal: High concentration in soils can be indicative of active hydrothermal activity Dictionary.png Mercury Vapor: Mercury is discharged as a highly volatile vapor during hydrothermal

125

Apparatus for isotopic alteration of mercury vapor  

DOE Patents [OSTI]

An apparatus for enriching the isotopic Hg content of mercury is provided. The apparatus includes a reactor, a low pressure electric discharge lamp containing a fill including mercury and an inert gas. A filter is arranged concentrically around the lamp. In a preferred embodiment, constant mercury pressure is maintained in the filter by means of a water-cooled tube that depends from it, the tube having a drop of mercury disposed in it. The reactor is arranged around the filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of a material which is transparent to ultraviolet light.

Grossman, Mark W. (Belmont, MA); George, William A. (Gloucester, MA); Marcucci, Rudolph V. (Danvers, MA)

1988-01-01T23:59:59.000Z

126

Stratified vapor generator  

DOE Patents [OSTI]

A stratified vapor generator (110) comprises a first heating section (H.sub.1) and a second heating section (H.sub.2). The first and second heating sections (H.sub.1, H.sub.2) are arranged so that the inlet of the second heating section (H.sub.2) is operatively associated with the outlet of the first heating section (H.sub.1). A moisture separator (126) having a vapor outlet (164) and a liquid outlet (144) is operatively associated with the outlet (124) of the second heating section (H.sub.2). A cooling section (C.sub.1) is operatively associated with the liquid outlet (144) of the moisture separator (126) and includes an outlet that is operatively associated with the inlet of the second heating section (H.sub.2).

Bharathan, Desikan (Lakewood, CO); Hassani, Vahab (Golden, CO)

2008-05-20T23:59:59.000Z

127

Is the light emitting diode (LED) an ultimate lamp?  

Science Journals Connector (OSTI)

Simple diagrams are used to show the transformation of a thin “slab” of intrinsic semiconductor (direct gap k elec =k hole ) from an ideal “flat-band” photopumped recombination-radiation light source into an ultimate lamp a p–n junctionlight emitting diode(LED). A photoexcited intrinsic slab of semiconductor can be regarded as an ideal (“flat-band”) light source with however the photogenerated carriers and voltage available externally instead of as recombination radiation (light) if the slab is converted to half p type (one side) and half n type (the other side) i.e. to a p–n junction. If an equal a “bucking ” external voltage is applied resulting in an input current when the photoexcitation is removed the slab becomes again (remains) an ideal “flat-band” light source a p–n junctionLED. In practice the LED takes the form of a p–n heterostructure in order to improve electron–hole injection reduce the absorption of recombination radiation and to make possible—with proper geometries—improved photon escape.

N. Holonyak Jr.

2000-01-01T23:59:59.000Z

128

LED Linear Lamps and Troffer Lighting: CALiPER Report Series 21  

Broader source: Energy.gov [DOE]

View the video about CALiPER Report Series 21 on LED Linear Lamps and Troffer Lighting, featuring interviews with Tracy Beeson and Naomi Miller of Pacific Northwest National Laboratory.

129

DOE Publishes CALiPER Report on Lumen and Chromaticity Maintenance of LED PAR38 Lamps  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy's CALiPER program has released Report 20.4, which is part of a series of investigations on LED PAR38 lamps. Report 20.4 focuses on lumen maintenance, chromaticity...

130

DOE Publishes CALiPER Snapshot Report on LED A Lamps  

Broader source: Energy.gov [DOE]

DOE's CALiPER program has released a Snapshot Report on LED A lamps, which utilizes the LED Lighting Facts program's extensive product database to help industry stakeholders understand the current state and trajectory of the market for that class

131

DOE Publishes New CALiPER Report on Subjective Evaluation of LED PAR38 Lamps  

Broader source: Energy.gov [DOE]

DOE has published the first in a series of four special investigations intended to extend the findings of CALiPER Application Summary Report 20: LED PAR38 Lamps, which was published late last year.

132

Text-Alternative Version: CALiPER Report Series 20 on LED PAR38 Lamps  

Broader source: Energy.gov [DOE]

Michael Royer, Lighting Engineer, Pacific Northwest National Laboratory: The CALiPER program looks at typical LED lamp performance attributes. As we've gone through the progression of reports, we...

133

MISSION CATHODIQUE A L'INTRIEUR DES LAMPES A INCANDESCENCE ; par M. L. HOULLEVIGUE (1).  

E-Print Network [OSTI]

523 �MISSION CATHODIQUE A L'INT�RIEUR DES LAMPES A INCANDESCENCE ; par M. L. HOULLEVIGUE (1). I. Lorsqu'on survolte fortement une lampe à incandescence à filament de charbon, par exemple en mettant sous incandescent. ' , Fic.. 1. Tous ces effets peuvent être attribués, en première analyse, aux électrons émanés du

Boyer, Edmond

134

ISSUANCE 2015-01-26: Energy Conservation Program: Energy Conservation Standards for High-Intensity Lamps, Notice to Reopen Comment Period  

Broader source: Energy.gov [DOE]

Energy Conservation Program: Energy Conservation Standards for High-Intensity Lamps, Notice to Reopen Comment Period

135

Demonstration of LED Retrofit Lamps at the Jordan Schnitzer Museum of Art  

SciTech Connect (OSTI)

The Jordan Schnitzer Museum of Art in Eugene, Oregon, houses a remarkable permanent collection of Asian art and antiquities, modern art, and sculpture, and also hosts traveling exhibitions. In the winter and spring of 2011, a series of digital photographs by artist Chris Jordan, titled "Running the Numbers," was exhibited in the Coeta and Donald Barker Special Exhibitions Gallery. These works graphically illustrate waste (energy, money, health, consumer objects, etc.) in contemporary culture. The Bonneville Power Administration and the Eugene Water and Electricity Board provided a set of Cree 12W light-emitting diode (LED) PAR38 replacement lamps (Cree LRP38) for the museum to test for accent lighting in lieu of their standard Sylvania 90W PAR38 130V Narrow Flood lamps (which draw 78.9W at 120V). At the same time, the museum tested LED replacement lamps from three other manufacturers, and chose the Cree lamp as the most versatile and most appropriate color product for this exhibit. The lamps were installed for the opening of the show in January 2011. This report describes the process for the demonstration, the energy and economic results, and results of a survey of the museum staff and gallery visitors on four similar clusters of art lighted separately by four PAR38 lamps.

Miller, Naomi J.

2011-09-01T23:59:59.000Z

136

Vapor Barriers or Vapor Diffusion Retarders | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Home Air Sealing for New Home Construction Insulation Types of Insulation Insulation and Air Sealing Products and Services External Resources Find a Local AirVapor Barrier...

137

Vapor spill pipe monitor  

DOE Patents [OSTI]

The invention is a method and apparatus for continually monitoring the composition of liquefied natural gas flowing from a spill pipe during a spill test by continually removing a sample of the LNG by means of a probe, gasifying the LNG in the probe, and sending the vaporized LNG to a remote ir gas detector for analysis. The probe comprises three spaced concentric tubes surrounded by a water jacket which communicates with a flow channel defined between the inner and middle, and middle and outer tubes. The inner tube is connected to a pump for providing suction, and the probe is positioned in the LNG flow below the spill pipe with the tip oriented partly downward so that LNG is continuously drawn into the inner tube through a small orifice. The probe is made of a high thermal conductivity metal. Hot water is flowed through the water jacket and through the flow channel between the three tubes to provide the necessary heat transfer to flash vaporize the LNG passing through the inner channel of the probe. The gasified LNG is transported through a connected hose or tubing extending from the probe to a remote ir sensor which measures the gas composition.

Bianchini, G.M.; McRae, T.G.

1983-06-23T23:59:59.000Z

138

Hydrogen Cars and Water Vapor  

E-Print Network [OSTI]

. This cycle is currently under way with hydrogen fuel cells. As fuel cell cars are suggested as a solutionHydrogen Cars and Water Vapor D.W.KEITHANDA.E.FARRELL'S POLICY FORUM "Rethinking hydrogen cars" (18 misidentified as "zero-emissions vehicles." Fuel cell vehicles emit water vapor. A global fleet could have

Colorado at Boulder, University of

139

Energy-Efficient, High-Color-Rendering LED Lamps Using Oxyfluoride and Fluoride Phosphors  

SciTech Connect (OSTI)

LED lamps using phosphor downconversion can be designed to replace incandescent or halogen sources with a 'warm-white' correlated color temperature (CCT) of 2700-3200 K and a color rendering index (CRI) greater than 90. However, these lamps have efficacies of {approx}70% of standard 'cool-white' LED packages (CCT = 4500-6000 K; CRI = 75-80). In this report, we describe structural and luminescence properties of fluoride and oxyfluoride phosphors, specifically a (Sr,Ca){sub 3}(Al,Si)O{sub 4}(F,O):Ce{sup 3+} yellow-green phosphor and a K{sub 2}TiF{sub 6}:Mn{sup 4+} red phosphor, that can reduce this gap and therefore meet the spectral and efficiency requirements for high-efficacy LED lighting. LED lamps with a warm-white color temperature (3088 K), high CRI (90), and an efficacy of {approx}82 lm/W are demonstrated using these phosphors. This efficacy is {approx}85% of comparable cool-white lamps using typical Y{sub 3}Al{sub 5}O{sub 12}:Ce{sup 3+}-based phosphors, significantly reducing the efficacy gap between warm-white and cool-white LED lamps that use phosphor downconversion.

Setlur, A.; Radkov, E; Henderson, C; Her, J; Srivastava, A; Karkada, N; Kishore, M; Kumar, N; Aesram, D; et al.

2010-01-01T23:59:59.000Z

140

DOE Publishes Notice of Public Meeting and Availability of the Framework Document for General Service Lamps Energy Conservation Standards  

Broader source: Energy.gov [DOE]

The Department of Energy has published a Federal Register notice of public meeting and availability of the framework document regarding energy conservation standards for general service lamps.

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Fuel vapor control device  

SciTech Connect (OSTI)

A fuel vapor control device is described having a valve opening and closing a passage connecting a carburetor and a charcoal canister according to a predetermined temperature. A first coil spring formed by a ''shape memory effect'' alloy is provided to urge the valve to open the passage when the temperature is high. A second coil spring urges the valve to close the passage. A solenoid is provided to urge an armature against the valve to close the passage against the force of the first coil spring when the engine is running. The solenoid heats the first coil spring to generate a spring force therein when the engine is running. When the engine is turned off, the solenoid is deactivated, and the force of the first spring overcomes the force of the second spring to open the passage until such time as the temperature of the first spring drops below the predetermined temperature.

Ota, I.; Nishimura, Y.; Nishio, S.; Yogo, K.

1987-10-20T23:59:59.000Z

142

The Dust Settles on Water Vapor Feedback  

Science Journals Connector (OSTI)

...To understand water vapor feedback...shifts in the atmospheric circulation...caused a positive water vapor feedback...temperature. Condensation, evaporation...shifts in the atmospheric circulation...caused a positive water vapor feedback...temperature. Condensation, evaporation...

Anthony D. Del Genio

2002-04-26T23:59:59.000Z

143

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

Broader source: Energy.gov (indexed) [DOE]

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

144

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

145

Category:Mercury Vapor | Open Energy Information  

Open Energy Info (EERE)

search GEOTHERMAL ENERGYGeothermal Home Geothermalpower.jpg Looking for the Mercury Vapor page? For detailed information on Mercury Vapor as exploration techniques,...

146

Pump-lamp firing-pulse generator for solid-state lasers  

SciTech Connect (OSTI)

This paper describes a generator that provides, with maximum output-pulse amplitude, sequential or external firing of four INP16/250 (IFP-8000) lamps at a frequency of 1 Hz. The energy and time characteristics of the generator are improved as compared with similar devices, which provides a time instability of the delay between a generator-trigger pulse and the optical pumping pulse of + or - 1 usec. The output-pulse amplitude can be varied according to the type and number of lamps fired. Measures are taken to reduce the supply noise produced in firing-pulse generation and to increase the operating safety of the device.

Denishchik, Y.S.

1985-12-01T23:59:59.000Z

147

Filter for isotopic alteration of mercury vapor  

DOE Patents [OSTI]

A filter for enriching the .sup.196 Hg content of mercury, including a reactor, a low pressure electric discharge lamp containing a fill of mercury and an inert gas. A filter is arranged concentrically around the lamp. The reactor is arranged around said filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of quartz, and are transparent to ultraviolet light. The .sup.196 Hg concentration in the mercury fill is less than that which is present in naturally occurring mercury, that is less than about 0.146 atomic weight percent. Hydrogen is also included in the fill and serves as a quenching gas in the filter, the hydrogen also serving to prevent disposition of a dark coating on the interior of the filter.

Grossman, Mark W. (Belmont, MA); George, William A. (Gloucestor, MA)

1989-01-01T23:59:59.000Z

148

Filter for isotopic alteration of mercury vapor  

DOE Patents [OSTI]

A filter is described for enriching the [sup 196]Hg content of mercury, including a reactor, a low pressure electric discharge lamp containing a fill of mercury and an inert gas. A filter is arranged concentrically around the lamp. The reactor is arranged around said filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of quartz, and are transparent to ultraviolet light. The [sup 196]Hg concentration in the mercury fill is less than that which is present in naturally occurring mercury, that is, less than about 0.146 atomic weight percent. Hydrogen is also included in the fill and serves as a quenching gas in the filter, the hydrogen also serving to prevent disposition of a dark coating on the interior of the filter. 9 figs.

Grossman, M.W.; George, W.A.

1989-06-13T23:59:59.000Z

149

Vapor deposition of hardened niobium  

DOE Patents [OSTI]

A method of coating ceramic nuclear fuel particles containing a major amount of an actinide ceramic in which the particles are placed in a fluidized bed maintained at ca. 800.degree. to ca. 900.degree. C., and niobium pentachloride vapor and carbon tetrachloride vapor are led into the bed, whereby niobium metal is deposited on the particles and carbon is deposited interstitially within the niobium. Coating apparatus used in the method is also disclosed.

Blocher, Jr., John M. (Columbus, OH); Veigel, Neil D. (Columbus, OH); Landrigan, Richard B. (Columbus, OH)

1983-04-19T23:59:59.000Z

150

The Fuzzy Design of the Intelligent System for the Energy-Saving Lamps  

Science Journals Connector (OSTI)

In the paper, a intelligent system was proposed. It consists of variable converter and intelligent controller. Variable reactor which concludes variable reactance converter and power converter has wide applications in the soft starting, speed controlling ... Keywords: fuzzy control, variable reactor, intelligent control, power converter, Energy-Saving Lamps

Youxin Yuan; Kaihua Cui; Yiping Xiao; Tieliang Xu

2008-12-01T23:59:59.000Z

151

RF driven sulfur lamp having driving electrodes which face each other  

DOE Patents [OSTI]

A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.

Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.

1999-06-22T23:59:59.000Z

152

15 KJ FLASH LAMP, POWER CONDITIONING UNIT DESIGNED FOR SAFTY, RELIABILITY & MANUFACTURABILITY*  

SciTech Connect (OSTI)

A 15kJoule, Flash Lamp Power Conditioning Unit has been successfully designed, developed, and deployed in the National Ignition Facility (NIF) Preamplifier Modules (PAM). The primary design philosophy of this power conditioning unit (PCU) is safety, reliability, and manufacturability. Cost reduction over commercially equivalent systems was also achieved through an easily manufactured packaging design optimized to meet NIF requirements. While still maintaining low cost, the PCU design includes a robust control system, fault diagnostic system, and safety features. The pulsed power design includes 6 PFN modules, each including a dual series injection trigger transformer, that drive a total of 12 flash lamp loads. The lamps are individually triggered via a 20kV pulse produced by a 1kV, MCT switched capacitive discharge unit on the primary side of the trigger transformer. The remote control interface includes an embedded controller that captures flash lamp current wave forms and fault status for each shot. The embedded controller provides the flexibility of remotely adjusting both the main drive voltage from 1.6 to 2.5 kV and the trigger voltage from 0 to 20 kV.

James, G; Merritt, B; Dreifuerst, G; Strickland, S

2007-08-07T23:59:59.000Z

153

Laboratory for Advanced Materials Processing University of Maryland http://www.enma.umd.edu/LAMP  

E-Print Network [OSTI]

) = Rs x (L / W), with Rs: sheet resistance of a layer of this material The sheet resistance is expressedLaboratory for Advanced Materials Processing � University of Maryland http Operating Procedure for LAMP four point probe sheet resistance measurements Overview of 4 point probe

Rubloff, Gary W.

154

Report 20.3: Stress Testing of LED PAR38 Lamps  

Broader source: Energy.gov [DOE]

A small sample of each of the Application Summary Report 20 PAR38 lamp types underwent stress testing that included substantial temperature and humidity changes, electrical variation, and vibration. The results do not directly address expected lifetime, but can be compared with one another, as well as with benchmark conventional products, to assess the relative robustness of the product designs. (24 pages, December 2014)

155

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents [OSTI]

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp.

Simpson, James E. (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

156

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents [OSTI]

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp. 18 figs.

Simpson, J.E.

1999-06-08T23:59:59.000Z

157

Predicted Pulsed-Power/Flash-Lamp Performance of the NIF Main Amplifier  

SciTech Connect (OSTI)

The laser glass for the National Ignition Facility (NIF) Main Amplifier system is pumped by a system of 192 pulsed power/flash lamp assemblies. Each of these 192 assemblies consists of a 1.6 MJ (nominal) capacitor bank working with a Pre-Ionization/Lamp Check (PILC) pulser to drive an array of 40 flash lamps. This paper describes the predicted performance of these Power Conditioning System (PCS) modules in concert with flashlamp assemblies in NIF. Each flashlamp assembly consists of 20 parallel sets of lamps in series pairs. The sensitivity of system performance to various design parameters of the PILC pulser and the main capacitor bank is described. Results of circuit models are compared to sub-scale flashlamp tests and to measurements taken in tests of a PCS module driving a flashlamp assembly in the First Article NIF Test Module facility at Sandia National Laboratories. Also included are predictions from a physics-based, semi-empirical amplifier gain code.

Fulkerson, E. Steven; Hammond, Jud; Harjes, Henry C.; Moore, William B.S.; Smith, David L.; Wilson, J. Michael

1999-06-22T23:59:59.000Z

158

Issues, Models and Solutions for Triac Modulated Phase Dimming of LED Lamps  

E-Print Network [OSTI]

greater than incandescent lamps [1,2]. In fact, recent technological breakthroughs [3-7] in the high of LED lighting: An incandescent source produces 10 ­ 20 lumens/watt, while several manufacturers have? Incandescent bulbs primarily utilize phase modulating dimming through triac switches to control the power sent

Lehman, Brad

159

Hands On Science with NOAA TITLE: Plate Tectonics and Lava Lamps  

E-Print Network [OSTI]

and geological events?" Answer = heat from radioactive decay · Compare the light bulb in lava to Earth's internal in the lava lamp. · Plot recent earthquakes and volcanic activity on a world map and compare to the location.education.noaa.gov/Ocean_and_Coasts/Ocean_Floor_Features.html USGS Earthquake Hazards - http

160

Chemical vapor deposition sciences  

SciTech Connect (OSTI)

Chemical vapor deposition (CVD) is a widely used method for depositing thin films of a variety of materials. Applications of CVD range from the fabrication of microelectronic devices to the deposition of protective coatings. New CVD processes are increasingly complex, with stringent requirements that make it more difficult to commercialize them in a timely fashion. However, a clear understanding of the fundamental science underlying a CVD process, as expressed through computer models, can substantially shorten the time required for reactor and process development. Research scientists at Sandia use a wide range of experimental and theoretical techniques for investigating the science of CVD. Experimental tools include optical probes for gas-phase and surface processes, a range of surface analytic techniques, molecular beam methods for gas/surface kinetics, flow visualization techniques and state-of-the-art crystal growth reactors. The theoretical strategy uses a structured approach to describe the coupled gas-phase and gas-surface chemistry, fluid dynamics, heat and mass transfer of a CVD process. The software used to describe chemical reaction mechanisms is easily adapted to codes that model a variety of reactor geometries. Carefully chosen experiments provide critical information on the chemical species, gas temperatures and flows that are necessary for model development and validation. This brochure provides basic information on Sandia`s capabilities in the physical and chemical sciences of CVD and related materials processing technologies. It contains a brief description of the major scientific and technical capabilities of the CVD staff and facilities, and a brief discussion of the approach that the staff uses to advance the scientific understanding of CVD processes.

NONE

1992-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

The Vaporization Enthalpies and Vapor Pressures of Some Primary Amines of Pharmaceutical Importance by Correlation Gas  

E-Print Network [OSTI]

by Correlation Gas Chromatography Chase Gobble, Nigam Rath, and James Chickos* Department of Chemistry Information ABSTRACT: Vapor pressures, vaporization, and sublimation enthalpies of several pharmaceuticals and boiling temperatures when available. Sublimation enthalpies and vapor pressures are also evaluated for 1

Chickos, James S.

162

Data:208f7ef3-cfb5-4748-a8d8-d569f0491c16 | Open Energy Information  

Open Energy Info (EERE)

f7ef3-cfb5-4748-a8d8-d569f0491c16 f7ef3-cfb5-4748-a8d8-d569f0491c16 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Foley Board of Utilities Effective date: 1990/01/01 End date if known: Rate name: Unmetered Outdoor Lighting- 400W Mercury Vapor -With Pole Sector: Lighting Description: Dusk to dawn unmetered service is covered by charges set forth below which also cover initial installation of overhead lines, poles (where applicable), fixture assembly including four foot mounting hardware for standard luminaries and two foot mounting hardware for flood lights, and maintenance including lamp replacements due to burn outs. Such charges do not cover replacement of lamps, luminaries, brackets or overhead lines which are damaged or destroyed due to vandalism or any other cause beyond the Utility's control, such facilities damaged or destroyed under such circumstances to be replaced by the Utility at the Consumer's expense. Lamp renewals and required maintenance will be performed only during regular daytime working hours as soon as practical after notification by the Consumer of the necessity.

163

Data:7db38318-eb0e-4353-a5ba-5bf16d3e63e4 | Open Energy Information  

Open Energy Info (EERE)

db38318-eb0e-4353-a5ba-5bf16d3e63e4 db38318-eb0e-4353-a5ba-5bf16d3e63e4 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Foley Board of Utilities Effective date: 1990/01/01 End date if known: Rate name: Unmetered Outdoor Lighting- 175W Mercury Vapor -With Pole Sector: Lighting Description: Dusk to dawn unmetered service is covered by charges set forth below which also cover initial installation of overhead lines, poles (where applicable), fixture assembly including four foot mounting hardware for standard luminaries and two foot mounting hardware for flood lights, and maintenance including lamp replacements due to burn outs. Such charges do not cover replacement of lamps, luminaries, brackets or overhead lines which are damaged or destroyed due to vandalism or any other cause beyond the Utility's control, such facilities damaged or destroyed under such circumstances to be replaced by the Utility at the Consumer's expense. Lamp renewals and required maintenance will be performed only during regular daytime working hours as soon as practical after notification by the Consumer of the necessity.

164

Data:4ed3157d-7ba5-4c44-afbe-dbfad0390461 | Open Energy Information  

Open Energy Info (EERE)

157d-7ba5-4c44-afbe-dbfad0390461 157d-7ba5-4c44-afbe-dbfad0390461 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Foley Board of Utilities Effective date: 1990/01/01 End date if known: Rate name: Unmetered Outdoor Lighting- 400W Mercury Vapor -Without Pole Sector: Lighting Description: Dusk to dawn unmetered service is covered by charges set forth below which also cover initial installation of overhead lines, poles (where applicable), fixture assembly including four foot mounting hardware for standard luminaries and two foot mounting hardware for flood lights, and maintenance including lamp replacements due to burn outs. Such charges do not cover replacement of lamps, luminaries, brackets or overhead lines which are damaged or destroyed due to vandalism or any other cause beyond the Utility's control, such facilities damaged or destroyed under such circumstances to be replaced by the Utility at the Consumer's expense. Lamp renewals and required maintenance will be performed only during regular daytime working hours as soon as practical after notification by the Consumer of the necessity.

165

Data:A720c823-97ef-4e50-8ed2-e8187e45df59 | Open Energy Information  

Open Energy Info (EERE)

c823-97ef-4e50-8ed2-e8187e45df59 c823-97ef-4e50-8ed2-e8187e45df59 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Foley Board of Utilities Effective date: 1990/01/01 End date if known: Rate name: Unmetered Outdoor Lighting- 175W Mercury Vapor -Without Pole Sector: Lighting Description: Dusk to dawn unmetered service is covered by charges set forth below which also cover initial installation of overhead lines, poles (where applicable), fixture assembly including four foot mounting hardware for standard luminaries and two foot mounting hardware for flood lights, and maintenance including lamp replacements due to burn outs. Such charges do not cover replacement of lamps, luminaries, brackets or overhead lines which are damaged or destroyed due to vandalism or any other cause beyond the Utility's control, such facilities damaged or destroyed under such circumstances to be replaced by the Utility at the Consumer's expense. Lamp renewals and required maintenance will be performed only during regular daytime working hours as soon as practical after notification by the Consumer of the necessity.

166

Energy Savings and NOx Emissions Reduction Potential from the 2012 Federal Legislation to Phase Out Incandescent Lamps in Texas  

E-Print Network [OSTI]

Lamps in Texas Description Value Reference Total Housing Units in Texas in 2013: 10,204,056 Real Estate Center, Texas A&M University3, U.S. Census Bureau4 5 Average Lighting Electricity Usage per House: 1,946 kWh/yr NREL Building America Program6... Savings in Texas: 10,424,973 MWh/yr OSD CFL Savings in Texas: 28,562 MWh/day By 2013, it is estimated that total savings of 10,424,973 MWh/yr would be achieved from replacing incandescent lamps with compact fluorescent lamps (CFL) in residential...

Liu, Zi; Baltazar, Juan Carlos; Haberl, Jeff; Soman, Rohit

167

VAPORIZATION THERMODYNAMICS OF KCl. COMBINING VAPOR PRESSURE AND GRAVIMETRIC DATA  

E-Print Network [OSTI]

.B. Department of Chemistry, Moscow State University, Moscow, 119899, Russia Bonnell D.W., Hastie J.W. National temperature chemistry situations, vapor pressures are typically less than 100 kPa. The molar volume is p = 101325 Pa). The subscript trs denotes that the changeisfor a transition, typically sublimation

Rudnyi, Evgenii B.

168

LED lamp or bulb with remote phosphor and diffuser configuration with enhanced scattering properties  

DOE Patents [OSTI]

An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and an optical cavity. The optical cavity comprises a phosphor carrier having a conversions material and arranged over an opening to the cavity. The phosphor carrier comprises a thermally conductive transparent material and is thermally coupled to the heat sink structure. An LED based light source is mounted in the optical cavity remote to the phosphor carrier with light from the light source passing through the phosphor carrier. A diffuser dome is included that is mounted over the optical cavity, with light from the optical cavity passing through the diffuser dome. The properties of the diffuser, such as geometry, scattering properties of the scattering layer, surface roughness or smoothness, and spatial distribution of the scattering layer properties may be used to control various lamp properties such as color uniformity and light intensity distribution as a function of viewing angle.

Tong, Tao; Le Toquin, Ronan; Keller, Bernd; Tarsa, Eric; Youmans, Mark; Lowes, Theodore; Medendorp, Jr., Nicholas W; Van De Ven, Antony; Negley, Gerald

2014-11-11T23:59:59.000Z

169

Xenon flash lamp pumped self-frequency doubling NYAB pulsed laser  

Science Journals Connector (OSTI)

Neodymium doped yttrium aluminum borate (NYAB) crystals with sizes up to 45mm have been grown successfully. NYAB rod of 4 ? 12mm was pumped by xenon flash lamp, and several mJ of 0.53?m green laser output was obtained. The oscillation threshold, the pulse duration, the laser beam polarization, and the laser beam divergence were measured to be 78mJ, 100ns, 90% and 2mrad, respectively.

Luo Zundu; Jiang Aidong; Huang Yichuan; Qiu Minwang

1989-01-01T23:59:59.000Z

170

2015-01-28 Issuance: Test Procedure for Fluorescent Lamp Ballasts; Final Rule Correction  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register final rule correction regarding test procedures for fluorescent lamp ballasts, as issued by the Deputy Assistant Secretary for Energy Efficiency on January 28, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

171

Household Light Makes Global Heat: High Black Carbon Emissions From Kerosene Wick Lamps  

Science Journals Connector (OSTI)

(3) Lighting is another component of this household energy challenge, with millions of households still relying on simple liquid-fueled lamps, but little is known of the associated environmental and health impacts. ... For laboratory tests, CO2 and CO concentrations were measured in real-time with a Li-COR 6252 (Li-COR Biosciences, Lincoln, NE) and Horiba AIA-220 (Horiba, Kyoto, Japan) nondispersive infrared (NDIR) analyzer, respectively. ...

Nicholas L. Lam; Yanju Chen; Cheryl Weyant; Chandra Venkataraman; Pankaj Sadavarte; Michael A. Johnson; Kirk R. Smith; Benjamin T. Brem; Joseph Arineitwe; Justin E. Ellis; Tami C. Bond

2012-11-19T23:59:59.000Z

172

Vacuum vapor deposition gun assembly  

DOE Patents [OSTI]

A vapor deposition gun assembly includes a hollow body having a cylindrical outer surface and an end plate for holding an adjustable heat sink, a hot hollow cathode gun, two magnets for steering the plasma from the gun into a crucible on the heat sink, and a shutter for selectively covering and uncovering the crucible.

Zeren, Joseph D. (Boulder, CO)

1985-01-01T23:59:59.000Z

173

Creating markets for new products to replace incandescent lamps: The international experience  

SciTech Connect (OSTI)

Since the summer of 1995, several organizations have been in pursuit of what many consider the Holy Grail of lighting technology--a low-cost, drop-in, energy-efficient replacement for the incandescent lamp. This paper summarizes the international experience in attempting to catalyze the commercialization of a mass-market, replacement product that could have major impact on residential lighting energy consumption in US and EU homes. The technology procurement effort was originally spearheaded by US Federal Government through a loose collaboration between the Department of Defense (DoD), the Environmental Protection Agency (EPA) and the Department of Energy (DOE). The DoD agreed to serve as the anchor buyer for a low-cost, drop-in replacement product for standard-sized light bulbs that provide at least 30 percent energy savings compared to traditional incandescent lamps. In parallel to the US effort, the International Energy Agency launched a co-operative technology procurement effort by assembling large buyers' groups in Finland, the Netherlands, Sweden, and the United Kingdom to pull a similar efficient lighting product into the European market. The lukewarm response from lamp manufacturers to these two technology procurement efforts illustrates the challenges of transforming residential lighting from incandescent to efficient lighting.

Rubinstein, F.; Borg, N.; Horowitz, N.; Narel, T.; Morehouse, E.T. Jr.

1998-07-01T23:59:59.000Z

174

Performance of a novel LED lamp arrangement to reduce SNR fluctuation for multi-user visible light communication systems  

Science Journals Connector (OSTI)

This paper investigates the performance of our recently proposed LED lamp arrangement to reduce the SNR fluctuation from different locations in the room for multi-user visible light...

Wang, Zixiong; Yu, Changyuan; Zhong, Wen-De; Chen, Jian; Chen, Wei

2012-01-01T23:59:59.000Z

175

LNG Vaporizer Utilizing Vacuum Steam Condensing  

Science Journals Connector (OSTI)

This report concerns the field test results of a new type of peak-shaving LNG vaporizer (VSV) whose heat source is ... heat of vacuum steam to vaporize and superheat LNG within heat transfer tubes. Prior to the.....

Y. Miyata; M. Hanamure; H. Kujirai; Y. Sato…

1991-01-01T23:59:59.000Z

176

Running-Film Vaporizer for LNG  

Science Journals Connector (OSTI)

Advances in welding technology and steel fabrication techniques have permitted the development of a new concept in cryogenic vaporizers—the running-film plate vaporizer. Although similar in heat transfer philosop...

H. H. West; G. L. Puckett

1975-01-01T23:59:59.000Z

177

Vapor Retarder Classification- Building America Top Innovation  

Broader source: Energy.gov [DOE]

This Building America Innovations profile describes research in vapor retarders. Since 2006 the IRC has permitted Class III vapor retarders like latex paint (see list above) in all climate zones under certain conditions thanks to research by Building America teams.

178

Vapor phase modifiers for oxidative coupling  

DOE Patents [OSTI]

Volatilized metal compounds retard vapor phase alkane conversion reactions in oxidative coupling processes that convert lower alkanes to higher hydrocarbons.

Warren, Barbara K. (Charleston, WV)

1991-01-01T23:59:59.000Z

179

A New Rb Lamp Exciter Circuit for Rb atomic clocks and Studies on Transition from Ring to Red mode  

E-Print Network [OSTI]

In this paper we describe the development of novel RF exciter circuit for electrode less Rb lamp. The lamp exciter circuit is a RF oscillator with a a new configuration operating at 60 to 65 MHz frequency with 3 to 4 watt power. The Rb lamp is used in exciting the ground state hyperfine transitions in Rb atom in a glass cell placed inside a tuned microwave cavity, As the frequency of these hyperfine transitions is very stable it is used in the development of Rb atomic clock by phase locking the oven controlled crystal oscillator (OCXO) to this atomic transition frequency. The details of the Rb lamp exciter are presented in the paper.The Lamp is ideally operated in ring mode as in this mode the linewidth is narrow and there is no self reversal. However, high temperature and RF excitation power may drive the Rb lamp to red mode which gives rise to line broadening and self reversal. It is the experience that mode change from ring to red deteriorates the atomic signal strength and S/N. In this paper the reasons of mode change are also discussed.

Savita Singh; Bikash Ghosal; G M Saxena

2010-11-10T23:59:59.000Z

180

Impending U.S. lighting standards will boost market for halogen-infrared lamps: New product line expanding  

SciTech Connect (OSTI)

Many of the incandescent floodlights and spotlights manufactured today will not meet lighting efficiency standards taking effect in the US in 1995. As these models cease production, demand will grow for higher efficiency units to fill this huge market, which now totals about 100 million lamps per year. One prime contender is a new class of halogen lamps that use a spectrally selective coating to reflect heat back onto the filament, reducing the amount of electricity needed to generate light. GE Lighting`s Halogen-IR line is the only series of such lamps currently available to replace the conventional floodlights and spotlights that will be banned by the new standards. Other manufacturers may adopt the technology, however, and the Japanese producer Ushio already sells in the US a line of smaller halogen lamps with a similar heat-reflective coating. In terms of efficacy and lifetime, Halogen-IR lamps out perform standard incandescents and standard halogens, but fall far short of fluorescent, metal halide, and high-pressure sodium sources. These other lighting systems are more appropriate and cost-effective than incandescents for many ambient lighting applications. For accent lighting and other tasks that are best suited to incandescent lighting, however, the Halogen-IR lamp is often a superior choice.

Sardinsky, R.; Shepard, M.

1993-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Vapor Pressures and Heats of Vaporization of Primary Coal Tars  

Office of Scientific and Technical Information (OSTI)

/ PC92544-18 / PC92544-18 VAPOR PRESSURES AND HEATS OF VAPORIZATION OF PRIMARY COAL TARS FINAL REPORT Grant Dates: August, 1992 - November, 1996 Principal Authors: Eric M. Suuberg (PI) and Vahur Oja Report Submitted: April, 1997 Revised: July, 1997 Grant Number: DE-FG22-92PC92544 Report Submitted by: ERIC M. SUUBERG DIVISION OF ENGINEERING BROWN UNIVERSITY PROVIDENCE, RI 02912 TEL. (401) 863-1420 Prepared For: U. S. DEPT. OF ENERGY FEDERAL ENERGY TECHNOLOGY CENTER P.O. BOX 10940 PITTSBURGH, PA 15236 DR. KAMALENDU DAS, FETC, MORGANTOWN , WV TECHNICAL PROJECT OFFICER "US/DOE Patent Clearance is not required prior to the publication of this document" ii United States Government Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any

182

Vapor deposition of tantalum and tantalum compounds  

SciTech Connect (OSTI)

Tantalum, and many of its compounds, can be deposited as coatings with techniques ranging from pure, thermal chemical vapor deposition to pure physical vapor deposition. This review concentrates on chemical vapor deposition techniques. The paper takes a historical approach. The authors review classical, metal halide-based techniques and current techniques for tantalum chemical vapor deposition. The advantages and limitations of the techniques will be compared. The need for new lower temperature processes and hence new precursor chemicals will be examined and explained. In the last section, they add some speculation as to possible new, low-temperature precursors for tantalum chemical vapor deposition.

Trkula, M. [Los Alamos National Lab., NM (United States). Materials Science and Technology Div.

1996-04-01T23:59:59.000Z

183

Means and method for vapor generation  

DOE Patents [OSTI]

A liquid, in heat transfer contact with a surface heated to a temperature well above the vaporization temperature of the liquid, will undergo a multiphase (liquid-vapor) transformation from 0% vapor to 100% vapor. During this transition, the temperature driving force or heat flux and the coefficients of heat transfer across the fluid-solid interface, and the vapor percentage influence the type of heating of the fluid--starting as "feedwater" heating where no vapors are present, progressing to "nucleate" heating where vaporization begins and some vapors are present, and concluding with "film" heating where only vapors are present. Unstable heating between nucleate and film heating can occur, accompanied by possibly large and rapid temperature shifts in the structures. This invention provides for injecting into the region of potential unstable heating and proximate the heated surface superheated vapors in sufficient quantities operable to rapidly increase the vapor percentage of the multiphase mixture by perhaps 10-30% and thereby effectively shift the multiphase mixture beyond the unstable heating region and up to the stable film heating region.

Carlson, Larry W. (Oswego, IL)

1984-01-01T23:59:59.000Z

184

2014-10-14 Issuance: Test Procedures Correction for Fluorescent Lamp Ballasts; Notice of Proposed Rulemaking  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of proposed rulemaking regarding test procedures for fluorescent lamp ballasts, as issued by the Deputy Assistant Secretary for Energy Efficiency on October 14, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

185

Influence of the lamp filling on the pumping conditions in a pulsed YAG:Nd3+ laser  

Science Journals Connector (OSTI)

The pumping conditions in pulsed YAG:Nd3+ lasers are determined, to a great extent, by the filling and the discharge conditions in the pump lamps. It is reported that the highest efficiency under free-oscillation conditions was obtained when krypton discharge lamps were used. These lamps had a discharge gap 60 mm long and 5 mm in diameter. They emitted flashes of about 200 ?sec duration. The best results were obtained when the initial gas pressure was ~1000 torr and the discharge energy was W ~ 100–150 J. The efficiency was lower when the value of W was either larger or smaller. The nature of the filling had little effect on the laser efficiency when xenon and krypton lamps were used to provide energies W close to the nominal value of 250 J. The pumping conditions could not be improved significantly by the use of other fillings (inert gases or their mixtures were used). The principal results obtained were valid also when the lamps were operated at a repetition frequency of ? ? 10 Hz.

Vitalii M Podgaetskii; B V Skvortsov; A N Tokareva

1971-01-01T23:59:59.000Z

186

DOE Publishes Final Rule for the Request for Exclusion of 100 Watt R20 Short Incandescent Reflector Lamps from Energy Conservation Standards  

Broader source: Energy.gov [DOE]

The Department of Energy has published a final rule regarding the request for exclusion of 100 Watt R20 short incandescent reflector lamps from energy conservation standards.

187

Wick for metal vapor laser  

DOE Patents [OSTI]

An improved wick for a metal vapor laser is made of a refractory metal cylinder, preferably molybdenum or tungsten for a copper laser, which provides the wicking surface. Alternately, the inside surface of the ceramic laser tube can be metalized to form the wicking surface. Capillary action is enhanced by using wire screen, porous foam metal, or grooved surfaces. Graphite or carbon, in the form of chunks, strips, fibers or particles, is placed on the inside surface of the wick to reduce water, reduce metal oxides and form metal carbides.

Duncan, David B. (Livermore, CA)

1992-01-01T23:59:59.000Z

188

Non-Vapor Compression HVAC Technologies Report  

Broader source: Energy.gov [DOE]

While vapor-compression technologies have served heating, ventilation, and air-conditioning (HVAC) needs very effectively, and have been the dominant HVAC technology for close to 100 years, the conventional refrigerants used in vapor-compression equipment contribute to global climate change when released to the atmosphere. The Building Technologies Office is evaluating low-global warming potential (GWP) alternatives to vapor-compression technologies.

189

A theoretical study of the incandescent filament lamp performance under voltage flicker  

SciTech Connect (OSTI)

Incandescent filament lamp flicker, produced by voltage fluctuation, is a power quality problem that caused engineering concern since the onset of electrical illumination technology. The flicker phenomenon was analyzed and explained in early studies. Standards dealing with acceptable flicker levels are well known, nevertheless, today the discussion about flicker continues to be a top priority topic due to the fact that steady-state and transient voltage waveform distortion is a growing problem in low and medium voltage systems. In many situations voltage flicker is caused by subharmonics and interharmonics of voltage. Cycloconverters, welders and arc furnaces, eccentrically operating tools and integral cycle controlled power equipment are notorious for producing voltage flicker. The goal of this paper is to provide solid mathematical basis for the analytical modeling of incandescent filament lamp flicker when the voltage is nonsinusoidal. A mathematical model that enables the evaluation of the luminous flux modulation caused by noninteger harmonics (subharmonics and interharmonics) is presented. Three situations are detailed: square-wave voltage modulation, sinusoidal modulation and the case of noninteger harmonics with nearly contiguous frequencies.

Peretto, L. [Univ. of Bologna (Italy)] [Univ. of Bologna (Italy); Emanuel, A.E. [Worcester Polytechnic Inst., MA (United States)] [Worcester Polytechnic Inst., MA (United States)

1997-01-01T23:59:59.000Z

190

Mercury Vapor (Kooten, 1987) | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor (Kooten, 1987) Mercury Vapor (Kooten, 1987) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor (Kooten, 1987) Exploration Activity Details Location Unspecified Exploration Technique Mercury Vapor Activity Date Usefulness useful DOE-funding Unknown Notes Surface soil-mercury surveys are an inexpensive and useful exploration tool for geothermal resources. ---- Surface geochemical surveys for mercury were conducted in 16 areas in 1979-1981 by ARCO Oil and Gas Company as part of its geothermal evaluation program. Three techniques used together have proved satisfactory in evaluating surface mercury data. These are contouring, histograms and cumulative frequency plots of the data. Contouring geochemical data and constructing histograms are standard

191

Vapor phase modifiers for oxidative coupling  

DOE Patents [OSTI]

Volatilized metal compounds are described which are capable of retarding vapor phase alkane conversion reactions in oxidative coupling processes that convert lower alkanes to higher hydrocarbons.

Warren, B.K.

1991-12-17T23:59:59.000Z

192

Near real time vapor detection and enhancement using aerosol adsorption  

SciTech Connect (OSTI)

A vapor sample detection method where the vapor sample contains vapor and ambient air and surrounding natural background particles. The vapor sample detection method includes the steps of generating a supply of aerosol that have a particular effective median particle size, mixing the aerosol with the vapor sample forming aerosol and adsorbed vapor suspended in an air stream, impacting the suspended aerosol and adsorbed vapor upon a reflecting element, alternatively directing infrared light to the impacted aerosol and adsorbed vapor, detecting and analyzing the alternatively directed infrared light in essentially real time using a spectrometer and a microcomputer and identifying the vapor sample.

Novick, Vincent J.; Johnson, Stanley A.

1997-12-01T23:59:59.000Z

193

Near real time vapor detection and enhancement using aerosol adsorption  

DOE Patents [OSTI]

A vapor sample detection method is described where the vapor sample contains vapor and ambient air and surrounding natural background particles. The vapor sample detection method includes the steps of generating a supply of aerosol that have a particular effective median particle size, mixing the aerosol with the vapor sample forming aerosol and adsorbed vapor suspended in an air stream, impacting the suspended aerosol and adsorbed vapor upon a reflecting element, alternatively directing infrared light to the impacted aerosol and adsorbed vapor, detecting and analyzing the alternatively directed infrared light in essentially real time using a spectrometer and a microcomputer and identifying the vapor sample. 13 figs.

Novick, V.J.; Johnson, S.A.

1999-08-03T23:59:59.000Z

194

Near real time vapor detection and enhancement using aerosol adsorption  

DOE Patents [OSTI]

A vapor sample detection method where the vapor sample contains vapor and ambient air and surrounding natural background particles. The vapor sample detection method includes the steps of generating a supply of aerosol that have a particular effective median particle size, mixing the aerosol with the vapor sample forming aerosol and adsorbed vapor suspended in an air stream, impacting the suspended aerosol and adsorbed vapor upon a reflecting element, alternatively directing infrared light to the impacted aerosol and adsorbed vapor, detecting and analyzing the alternatively directed infrared light in essentially real time using a spectrometer and a microcomputer and identifying the vapor sample.

Novick, Vincent J. (Downers Grove, IL); Johnson, Stanley A. (Countryside, IL)

1999-01-01T23:59:59.000Z

195

G-Band Vapor Radiometer Precipitable Water Vapor (GVRPWV) Value-Added Product  

SciTech Connect (OSTI)

The G-Band Vapor Radiometer Precipitable Water Vapor (GVRPWV) value-added product (VAP) computes precipitable water vapor using neural network techniques from data measured by the GVR. The GVR reports time-series measurements of brightness temperatures for four channels located at 183.3 ± 1, 3, 7, and 14 GHz.

Koontz, A; Cadeddu, M

2012-12-05T23:59:59.000Z

196

Data:F6fe3d2b-9a67-4661-aab9-906f806c7860 | Open Energy Information  

Open Energy Info (EERE)

fe3d2b-9a67-4661-aab9-906f806c7860 fe3d2b-9a67-4661-aab9-906f806c7860 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 250W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Open',WoodPole(2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

197

Data:C77c3d84-c745-414a-9bf4-64461174d5f5 | Open Energy Information  

Open Energy Info (EERE)

d84-c745-414a-9bf4-64461174d5f5 d84-c745-414a-9bf4-64461174d5f5 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 250W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',Wood Pole (2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

198

Data:5d47e2c5-b74e-42a0-8742-f681cf68d808 | Open Energy Information  

Open Energy Info (EERE)

b74e-42a0-8742-f681cf68d808 b74e-42a0-8742-f681cf68d808 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 175 Mercury vapor with Underground Wiring- (Type - 'MV-Open', Wood Pole) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

199

Data:A0610d5a-0d14-40dc-98f2-5ff2f1d0d0f9 | Open Energy Information  

Open Energy Info (EERE)

d14-40dc-98f2-5ff2f1d0d0f9 d14-40dc-98f2-5ff2f1d0d0f9 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 100W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Open',Wood Pole (2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

200

Data:D2f0bffd-3563-4d8e-81ec-163f1d467c90 | Open Energy Information  

Open Energy Info (EERE)

bffd-3563-4d8e-81ec-163f1d467c90 bffd-3563-4d8e-81ec-163f1d467c90 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 100W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',Wood Pole (1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Data:D7d3063f-e70a-42c6-bb24-1ba43357e1f1 | Open Energy Information  

Open Energy Info (EERE)

63f-e70a-42c6-bb24-1ba43357e1f1 63f-e70a-42c6-bb24-1ba43357e1f1 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 1000W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',WoodPole(2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

202

Data:00dd7c09-314c-462d-a80f-e04bf442d845 | Open Energy Information  

Open Energy Info (EERE)

dd7c09-314c-462d-a80f-e04bf442d845 dd7c09-314c-462d-a80f-e04bf442d845 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 250W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',FiberglassPole(3)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

203

Data:720229fa-4def-4aff-a9ea-d618d5d26d85 | Open Energy Information  

Open Energy Info (EERE)

29fa-4def-4aff-a9ea-d618d5d26d85 29fa-4def-4aff-a9ea-d618d5d26d85 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 100W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Open',WoodPole(2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

204

Data:Dd205841-ee54-42f5-9926-1bb2cb44a1df | Open Energy Information  

Open Energy Info (EERE)

1-ee54-42f5-9926-1bb2cb44a1df 1-ee54-42f5-9926-1bb2cb44a1df No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 400W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',Wood Pole (2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

205

Data:C3d85855-db40-41bb-bed9-897e00363be0 | Open Energy Information  

Open Energy Info (EERE)

db40-41bb-bed9-897e00363be0 db40-41bb-bed9-897e00363be0 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 250W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Open',Wood Pole (1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

206

Data:Ffb4a356-232a-4dcd-aa77-4fc9428a66aa | Open Energy Information  

Open Energy Info (EERE)

Ffb4a356-232a-4dcd-aa77-4fc9428a66aa Ffb4a356-232a-4dcd-aa77-4fc9428a66aa No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 100W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',Wood Pole (2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

207

Data:1154ef1b-9514-41f3-a8c6-19b81b300d6b | Open Energy Information  

Open Energy Info (EERE)

b-9514-41f3-a8c6-19b81b300d6b b-9514-41f3-a8c6-19b81b300d6b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 150W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',Wood Pole (1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

208

Data:E08b82a8-7a08-491e-acd6-cfdf7c886863 | Open Energy Information  

Open Energy Info (EERE)

a8-7a08-491e-acd6-cfdf7c886863 a8-7a08-491e-acd6-cfdf7c886863 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 400W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'MH-Flood',Wood Pole (2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

209

Data:De0184f8-cc77-48a2-86d5-44057ee7338b | Open Energy Information  

Open Energy Info (EERE)

184f8-cc77-48a2-86d5-44057ee7338b 184f8-cc77-48a2-86d5-44057ee7338b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 150W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Open',Wood Pole (2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

210

Data:29df3e4a-5e2a-44a8-b357-1257fedeefef | Open Energy Information  

Open Energy Info (EERE)

e4a-5e2a-44a8-b357-1257fedeefef e4a-5e2a-44a8-b357-1257fedeefef No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 1000W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',Wood Pole (1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

211

Data:D696c0f7-a829-41b4-a2b4-ee1249954159 | Open Energy Information  

Open Energy Info (EERE)

f7-a829-41b4-a2b4-ee1249954159 f7-a829-41b4-a2b4-ee1249954159 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 150W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Open',Wood Pole (1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

212

Data:C3f5d03b-97da-4746-b120-870bc162ff36 | Open Energy Information  

Open Energy Info (EERE)

3b-97da-4746-b120-870bc162ff36 3b-97da-4746-b120-870bc162ff36 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 400W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',FiberglassPole(3)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

213

Data:A81693b8-f594-43ef-91a0-13196a1745fd | Open Energy Information  

Open Energy Info (EERE)

693b8-f594-43ef-91a0-13196a1745fd 693b8-f594-43ef-91a0-13196a1745fd No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 100W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',FiberglassPole(3)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

214

Data:5668e93c-dce4-45e6-b300-7dd65b9388ca | Open Energy Information  

Open Energy Info (EERE)

dce4-45e6-b300-7dd65b9388ca dce4-45e6-b300-7dd65b9388ca No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 400W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',Wood Pole (2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

215

Data:E95973fd-5bd0-4882-8630-22f0ab0d61f8 | Open Energy Information  

Open Energy Info (EERE)

973fd-5bd0-4882-8630-22f0ab0d61f8 973fd-5bd0-4882-8630-22f0ab0d61f8 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 150W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',WoodPole(2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

216

Data:5276e5ae-2759-4a8f-b7aa-b2cb352dd958 | Open Energy Information  

Open Energy Info (EERE)

2759-4a8f-b7aa-b2cb352dd958 2759-4a8f-b7aa-b2cb352dd958 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 400W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',Wood Pole (1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

217

Data:4611d636-a211-412b-a0c7-846b1cea86fe | Open Energy Information  

Open Energy Info (EERE)

6-a211-412b-a0c7-846b1cea86fe 6-a211-412b-a0c7-846b1cea86fe No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 400W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'MH-Flood',Wood Pole (1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

218

Data:Cb5db7ec-7824-4bcd-9eb4-db5ebc499985 | Open Energy Information  

Open Energy Info (EERE)

ec-7824-4bcd-9eb4-db5ebc499985 ec-7824-4bcd-9eb4-db5ebc499985 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 250W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',Wood Pole (1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

219

Data:A31d1215-ebc0-411c-a794-8ed5351d7bf2 | Open Energy Information  

Open Energy Info (EERE)

15-ebc0-411c-a794-8ed5351d7bf2 15-ebc0-411c-a794-8ed5351d7bf2 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 250W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',Wood Pole (1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

220

Data:A0b4aae3-b1b4-409c-94cb-438e452edc70 | Open Energy Information  

Open Energy Info (EERE)

aae3-b1b4-409c-94cb-438e452edc70 aae3-b1b4-409c-94cb-438e452edc70 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 100W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',WoodPole(2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Data:47ef0a4b-1249-421a-872c-1b88da72666a | Open Energy Information  

Open Energy Info (EERE)

a4b-1249-421a-872c-1b88da72666a a4b-1249-421a-872c-1b88da72666a No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 250W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',FiberglassPole(3)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

222

Data:2565df0a-e218-496f-ba53-356852cec5f1 | Open Energy Information  

Open Energy Info (EERE)

df0a-e218-496f-ba53-356852cec5f1 df0a-e218-496f-ba53-356852cec5f1 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 1000W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',FiberglassPole(3)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

223

Data:913556b2-1c60-478c-95cc-befbed81a632 | Open Energy Information  

Open Energy Info (EERE)

b2-1c60-478c-95cc-befbed81a632 b2-1c60-478c-95cc-befbed81a632 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 250W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Open',Wood Pole (2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

224

Data:8cf92623-bb67-44fd-be96-4e50bcd00d83 | Open Energy Information  

Open Energy Info (EERE)

623-bb67-44fd-be96-4e50bcd00d83 623-bb67-44fd-be96-4e50bcd00d83 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 400W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',WoodPole(2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

225

Data:E75422b7-2867-40a1-8949-46d94a802771 | Open Energy Information  

Open Energy Info (EERE)

2b7-2867-40a1-8949-46d94a802771 2b7-2867-40a1-8949-46d94a802771 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 400W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'MH-Flood',WoodPole(2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

226

Data:Eb047549-4371-48e9-b11c-b75d3f056969 | Open Energy Information  

Open Energy Info (EERE)

49-4371-48e9-b11c-b75d3f056969 49-4371-48e9-b11c-b75d3f056969 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 175 Existing mercury vapor with Overhead Wiring - (Type - 'MV-Open', Additional Overhead - Wood Pole(2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

227

Data:D76f1eb3-e7ee-4110-a076-a58b42c300c1 | Open Energy Information  

Open Energy Info (EERE)

eb3-e7ee-4110-a076-a58b42c300c1 eb3-e7ee-4110-a076-a58b42c300c1 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 400W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',Wood Pole (1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

228

Data:8a7dcaeb-4963-41ff-bab8-e5ffe262ab35 | Open Energy Information  

Open Energy Info (EERE)

dcaeb-4963-41ff-bab8-e5ffe262ab35 dcaeb-4963-41ff-bab8-e5ffe262ab35 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 150W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',FiberglassPole(3)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

229

Data:7b64a4da-0bf0-42cc-a127-e98af1315dbc | Open Energy Information  

Open Energy Info (EERE)

da-0bf0-42cc-a127-e98af1315dbc da-0bf0-42cc-a127-e98af1315dbc No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 100W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Open',Wood Pole (1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

230

Data:Db3ae22d-d126-4247-99c6-d30aa5fc1ee6 | Open Energy Information  

Open Energy Info (EERE)

2d-d126-4247-99c6-d30aa5fc1ee6 2d-d126-4247-99c6-d30aa5fc1ee6 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 250W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Open',Wood Pole (1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

231

Data:48b7a0b2-636f-43f4-aecf-81d528578d22 | Open Energy Information  

Open Energy Info (EERE)

b2-636f-43f4-aecf-81d528578d22 b2-636f-43f4-aecf-81d528578d22 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 150W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',Wood Pole (2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

232

Data:4c2db101-0719-4488-91b5-0c10305b4ae2 | Open Energy Information  

Open Energy Info (EERE)

-0719-4488-91b5-0c10305b4ae2 -0719-4488-91b5-0c10305b4ae2 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 175 Existing mercury vapor with Overhead Wiring - (Type - 'MV-Open', Existing Overhead - Wood Pole(1)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

233

Data:26f8315a-f068-43a6-8731-d726fb8fea9e | Open Energy Information  

Open Energy Info (EERE)

f068-43a6-8731-d726fb8fea9e f068-43a6-8731-d726fb8fea9e No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 250W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',Wood Pole (2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

234

Data:1eed3a36-f12a-4353-b92b-d5c5c0281e45 | Open Energy Information  

Open Energy Info (EERE)

eed3a36-f12a-4353-b92b-d5c5c0281e45 eed3a36-f12a-4353-b92b-d5c5c0281e45 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 175 Mercury vapor with Underground Wiring- (Type - 'MV-Open', Fiberglass Pole) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

235

Data:658f281c-9aff-4718-97d0-9fcf9f780d6f | Open Energy Information  

Open Energy Info (EERE)

c-9aff-4718-97d0-9fcf9f780d6f c-9aff-4718-97d0-9fcf9f780d6f No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 1000W Overhead Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',Wood Pole (2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

236

Data:62025b45-1476-40b8-9979-e21c1b18a721 | Open Energy Information  

Open Energy Info (EERE)

b45-1476-40b8-9979-e21c1b18a721 b45-1476-40b8-9979-e21c1b18a721 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 400W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'MH-Flood',FiberglassPole(3)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

237

Quantitative organic vapor-particle sampler  

DOE Patents [OSTI]

A quantitative organic vapor-particle sampler for sampling semi-volatile organic gases and particulate components. A semi-volatile organic reversible gas sorbent macroreticular resin agglomerates of randomly packed microspheres with the continuous porous structure of particles ranging in size between 0.05-10 .mu.m for use in an integrated diffusion vapor-particle sampler.

Gundel, Lara (Berkeley, CA); Daisey, Joan M. (Walnut Creek, CA); Stevens, Robert K. (Cary, NC)

1998-01-01T23:59:59.000Z

238

LNG fire and vapor control system technologies  

SciTech Connect (OSTI)

This report provides a review of fire and vapor control practices used in the liquefied natural gas (LNG) industry. Specific objectives of this effort were to summarize the state-of-the-art of LNG fire and vapor control; define representative LNG facilities and their associated fire and vapor control systems; and develop an approach for a quantitative effectiveness evaluation of LNG fire and vapor control systems. In this report a brief summary of LNG physical properties is given. This is followed by a discussion of basic fire and vapor control design philosophy and detailed reviews of fire and vapor control practices. The operating characteristics and typical applications and application limitations of leak detectors, fire detectors, dikes, coatings, closed circuit television, communication systems, dry chemicals, water, high expansion foam, carbon dioxide and halogenated hydrocarbons are described. Summary descriptions of a representative LNG peakshaving facility and import terminal are included in this report together with typical fire and vapor control systems and their locations in these types of facilities. This state-of-the-art review identifies large differences in the application of fire and vapor control systems throughout the LNG industry.

Konzek, G.J.; Yasutake, K.M.; Franklin, A.L.

1982-06-01T23:59:59.000Z

239

The Model 5000-16C 1000 WATT FEL Lamp Standard pro-vides absolute calibration of spectral irradiance from 250 nm to  

E-Print Network [OSTI]

The Model 5000-16C 1000 WATT FEL Lamp Standard pro- vides absolute calibration of spectral. It has been selected by the National Institute of Standards and Technology to replace the 1000 watt, DXW-pin 1000 watt lamp that is adapted by Gamma Scientific into a bi-post configuration. It is used

240

ARM - Field Campaign - Water Vapor IOP  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

govCampaignsWater Vapor IOP govCampaignsWater Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Water Vapor IOP 2000.09.18 - 2000.10.08 Lead Scientist : Henry Revercomb Data Availability Yes For data sets, see below. Description Scientific hypothesis: 1. Microwave radiometer (MWR) observations of the 22 GHz water vapor line can accurately constrain the total column amount of water vapor (assuming a calibration accuracy of 0.5 degC or better, which translates into 0.35 mm PWV). 2. Continuous profiling by Raman lidar provides a stable reference for handling sampling problems and observes a fixed column directly above the site only requiring a single height- independent calibration factor. 3. Agreement between the salt-bath calibrated in-situ probes, chilled

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Effect of helium addition on discharge characteristics in a flat fluorescent lamp  

SciTech Connect (OSTI)

The discharge characteristics of a multielectrode dual coplanar in a mercury-free flat fluorescent lamp were investigated using brightness-efficiency measurement and the infrared (IR) spectrum and intensified charge coupled device (ICCD) characteristics. The level of brightness was above 14 900 cd/m{sup 2} under the conditions of neon--50% xenon-8% He gas composition, 150 Torr pressure, and 20 kHz alternating current pulse. The ICCD results revealed a faster and wider discharge with a Ne-50% Xe-8% He gas composition. The effect of adding helium (He) to Ne-50% Xe revealed a faster peak emission, as confirmed by ICCD images. From the gated IR emission spectrum, the intensity ratio of I{sub 823nm}/I{sub 828nm} was {approx}8% higher with Ne-50% Xe-8% He than with Ne-50% Xe under the same pressure and applied voltage conditions.

Lee, Seong-Eui; Lee, Ho-Nyeon; Park, Hyoung-Bin; Lee, Kyo Sung; Choi, Kyung Cheol [Materials and Devices Research Center, Samsung Advanced Institute of Technology, Suwon 440-600 (Korea, Republic of); Department of Electronics Engineering, Sejong University, Seoul 143-747 (Korea, Republic of); Department of Electrical Engineering and Computer Science, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 305-701 (Korea, Republic of)

2005-11-01T23:59:59.000Z

242

A Novel High-Power-Factor LED-Lamp Driver Based on a Single-Stage Power Conversion  

Science Journals Connector (OSTI)

This paper proposes a novel single-stage driver for supplying a T8-type light-emitting diode (LED) lamp with high power factor. The presented driver integrates a dual buck-boost converter with coupled inductors and a half-bridge series-resonant converter ... Keywords: converter, driver, light-emitting diode (LED)

Chun An Cheng, En Chih Chang, Ching Shien Tseng, Tsung Yuan Chung

2014-06-01T23:59:59.000Z

243

New Energy Efficiency Standards for Metal Halide Lamp Fixtures to Save on Energy Bills and Reduce Carbon Pollution  

Office of Energy Efficiency and Renewable Energy (EERE)

As part of the Energy Department’s efforts to develop efficiency standards that cut carbon pollution and save money by saving energy, U.S. Energy Secretary Ernest Moniz announced that the Department has finalized new energy efficiency standards for metal halide lamp fixtures.

244

Energy balance in laser-irradiated vaporizing droplets  

Science Journals Connector (OSTI)

The interactions of vaporizing aerosols with a high energy laser beam are analyzed in the diffusive vaporization regime. This is the regime in which diffusive mass transport and...

Zardecki, Andrew; Armstrong, Robert L

1988-01-01T23:59:59.000Z

245

Ground Gravity Survey At Cove Fort Area - Vapor (Warpinski, Et...  

Open Energy Info (EERE)

Vapor (Warpinski, Et Al., 2004) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Gravity Survey At Cove Fort Area - Vapor (Warpinski, Et...

246

Hydrogen-Bond Acidic Polymers for Chemical Vapor Sensing. | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Acidic Polymers for Chemical Vapor Sensing. Hydrogen-Bond Acidic Polymers for Chemical Vapor Sensing. Abstract: A review with 171 references. Hydrogen-bond acidic polymers for...

247

Recovering hydrocarbons from hydrocarbon-containing vapors  

DOE Patents [OSTI]

Values are recovered from a hydrocarbon-containing vapor by contacting the vapor with quench liquid consisting essentially of hydrocarbons to form a condensate and a vapor residue, the condensate and quench fluid forming a combined liquid stream. The combined liquid stream is mixed with a viscosity-lowering liquid to form a mixed liquid having a viscosity lower than the viscosity of the combined liquid stream to permit easy handling of the combined liquid stream. The quench liquid is a cooled portion of the mixed liquid. Viscosity-lowering liquid is separated from a portion of the mixed liquid and cycled to form additional mixed liquid.

Mirza, Zia I. (La Verne, CA); Knell, Everett W. (Los Alamitos, CA); Winter, Bruce L. (Danville, CA)

1980-09-30T23:59:59.000Z

248

DOE CALiPER Program, Report 21.2: Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers  

SciTech Connect (OSTI)

Although lensed troffers are numerous, there are many other types of optical systems as well. This report looked at the performance of three linear (T8) LED lamps chosen primarily based on their luminous intensity distributions (narrow, medium, and wide beam angles) as well as a benchmark fluorescent lamp in five different troffer types. Also included are the results of a subjective evaluation. Results show that linear (T8) LED lamps can improve luminaire efficiency in K12-lensed and parabolic-louvered troffers, effect little change in volumetric and high-performance diffuse-lensed type luminaires, but reduce efficiency in recessed indirect troffers. These changes can be accompanied by visual appearance and visual comfort consequences, especially when LED lamps with clear lenses and narrow distributions are installed. Linear (T8) LED lamps with diffuse apertures exhibited wider beam angles, performed more similarly to fluorescent lamps, and received better ratings from observers. Guidance is provided on which luminaires are the best candidates for retrofitting with linear (T8) LED lamps.

Miller, Naomi J.; Perrin, Tess E.; Royer, Michael P.; Wilkerson, Andrea M.; Beeson, Tracy A.

2014-05-20T23:59:59.000Z

249

Aerogel composites using chemical vapor infiltration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Aerogel composites using chemical vapor infiltration Aerogel composites using chemical vapor infiltration Title Aerogel composites using chemical vapor infiltration Publication Type Journal Article Year of Publication 1995 Authors Hunt, Arlon J., Michael R. Ayers, and Wanqing Cao Journal Journal of Non-Crystalline Solids Volume 185 Pagination 227-232 Abstract A new method to produce novel composite materials based on the use of aerogels as a starting material is described. Using chemical vapor infiltration, a variety of solid materials were thermally deposited into the open pore structure of aerogel. The resulting materials possess new and unusual properties including photoluminescence, magnetism and altered optical properties. An important characteristic of this preparation process is the very small size of the deposits that gives rise to new behaviors. Silicon deposits exhibit photoluminescence, indicating quantum confinement. Two or more phases may be deposited simultaneously and one or both chemically or thermally reacted to produce new structures.

250

Chemical vapor detection using nanomechanical platform  

Science Journals Connector (OSTI)

For high sensitive and multiplexed chemical analysis, an opto-mechanical detection platform has been built. To check the performance of the platform, we performed water vapor response measurements for ... sensors...

S. H. Lim

2007-11-01T23:59:59.000Z

251

Chemical vapor deposition of functionalized isobenzofuran polymers  

E-Print Network [OSTI]

This thesis develops a platform for deposition of polymer thin films that can be further tailored by chemical surface modification. First, we explore chemical vapor deposition of functionalized isobenzofuran films using ...

Olsson, Ylva Kristina

2007-01-01T23:59:59.000Z

252

Vapor Power Systems MAE 4263 Final Exam  

E-Print Network [OSTI]

Vapor Power Systems MAE 4263 Final Exam Wednesday, May 5, 2004 Prof. P.M. Moretti Key Instructions, then think, then write! 1. What is the dewpoint of the exhaust of your car, if the gasoline consists2 so that the mole fraction of water vapor is yH2 O = 9 9 + 8 + 47 = 0:14063 pH2 O = 0:14063 14

253

Color stable phosphors for LED lamps and methods for preparing them  

SciTech Connect (OSTI)

An LED lamp includes a light source configured to emit radiation with a peak intensity at a wavelength between about 250 nm and about 550 nm; and a phosphor composition configured to be radiationally coupled to the light source. The phosphor composition includes particles of a phosphor of formula I, said particles having a coating composition disposed on surfaces thereof; ((Sr.sub.1-zM.sub.z).sub.1-(x+w)A.sub.wCe.sub.x).sub.3(Al.sub.1-ySi.sub.y-)O.sub.4+y+3(x-w)F.sub.1-y-3(x-w) I wherein the coating composition comprises a material selected from aluminum oxide, magnesium oxide, calcium oxide, barium oxide, strontium oxide, zinc oxide, aluminum hydroxide, magnesium hydroxide, calcium hydroxide, barium hydroxide, strontium hydroxide, zinc hydroxide, aluminum phosphate, magnesium phosphate, calcium phosphate, barium phosphate, strontium phosphate, and combinations thereof; and A is Li, NA, K, or Rb, or a combination thereof; M is Ca, Ba, Mg, Zn, or a combination thereof; and 0

Murphy, James Edward; Setlur, Anant Achyut; Camardello, Samuel Joseph

2013-11-26T23:59:59.000Z

254

Iterative Boltzmann plot method for temperature and pressure determination in a xenon high pressure discharge lamp  

SciTech Connect (OSTI)

The Boltzmann plot method allows to calculate plasma temperatures and pressures if absolutely calibrated emission coefficients of spectral lines are available. However, xenon arcs are not very well suited to be analyzed this way, as there are only a limited number of lines with atomic data available. These lines have high excitation energies in a small interval between 9.8 and 11.5 eV. Uncertainties in the experimental method and in the atomic data further limit the accuracy of the evaluation procedure. This may result in implausible values of temperature and pressure with inadmissible uncertainty. To omit these shortcomings, an iterative scheme is proposed that is making use of additional information about the xenon fill pressure. This method is proved to be robust against noisy data and significantly reduces the uncertainties. Intentionally distorted synthetic data are used to illustrate the performance of the method, and measurements performed on a laboratory xenon high pressure discharge lamp are analyzed resulting in reasonable temperatures and pressures with significantly reduced uncertainties.

Zalach, J.; Franke, St. [INP Greifswald, Felix-Hausdorff-Str. 2, 17489 Greifswald (Germany)

2013-01-28T23:59:59.000Z

255

Analysis of Na and Ba in an atomic fluorescence method with excitation by a pulsed dye laser with lamp pumping  

SciTech Connect (OSTI)

Among the laser methods used in atomic spectroscopy, atomic fluorescence resonance spectroscopy together with an atomic ionization technique make it possible to work with individual atoms. This paper reports on the determination of Na and Ba in aqueous solutions of their salts with atomic fluorescence analysis performed wih a dye laser and lamp pumping, the pulse of generation having a length of 1-2 usec. The detection limit of elements in atomic fluorescence analysis performed wih dye lasers with lamp pumping can be reduced by increasing the spectral density of the laser radiation through narrowing the line of generation, by employing other dyes to excite lines of greater intensity, by improving the recording system of the fluorescence spectra, and by improving the atomization of the samples to be analyzed.

Kukvshim, V.G.

1986-04-01T23:59:59.000Z

256

Design and Realize of the Graphics Platform for LED Lamps’ Layout Based on GDI+ and Dual-Buffer  

Science Journals Connector (OSTI)

Based on the GDI+ class library and dual-buffer technology of .NET framework, the software for LED lamps’ layout is developed. On the basis of determining the scheme of layout platform, the metafile class library model by Composite design-set and the process of calling the LED pixels metafile symbol interface are designed firstly. The design method of realizing the LED pixels metafile visual editing on the drawn LED logical pixel based on GDI+ is analyzed. The dual-buffer technology is used to solve the problem of flicker when fast refreshing. The testing results show that the platform can meet the basic function requirements of engineering application, and realize partial adjust on the process of LED lamps layout without distortion.

Wen Yuanmei; Nie Xinming; Liu Guixiong

2012-01-01T23:59:59.000Z

257

Vapor Pressures and Vaporization, Sublimation, and Fusion Enthalpies of Some Fatty Acids  

E-Print Network [OSTI]

Vapor Pressures and Vaporization, Sublimation, and Fusion Enthalpies of Some Fatty Acids Joe A. Wilson and James S. Chickos* Department of Chemistry and Biochemistry, University of MissouriSt. Louis, St. Louis, Missouri 63121, United States *S Supporting Information ABSTRACT: Sublimation enthalpies

Chickos, James S.

258

Vapor Pressures and Vaporization Enthalpies of a Series of Dialkyl Phthalates by Correlation Gas Chromatography  

E-Print Network [OSTI]

Chromatography Chase Gobble and James Chickos* Department of Chemistry and Biochemistry University of Missouri-St. Louis, St. Louis Missouri 63121, United States Sergey P. Verevkin Department of Physical Chemistry: Experimental vapor pressures, vaporization, fusion and sublimation enthalpies of a number of dialkyl

Chickos, James S.

259

Mechanical design of PlayLamp : a minimally intrusive device for recording the behavior of children at-risk of developmental disorders  

E-Print Network [OSTI]

This thesis paper documents the design process, decisions, and outcomes of the design of the physical form factor of PlayLamp, a device for video and audio recording the development of children at-risk of having developmental ...

Steger, Stephen Andrew

2008-01-01T23:59:59.000Z

260

CALiPER Report 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps  

Broader source: Energy.gov [DOE]

This December 3, 2013 webinar explored the findings of CALiPER 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps and discussed what attributes to...

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Local Resistance Profiling of Ultra Shallow Junction Annealed with Combination of Spike Lamp and Laser Annealing Processes using Scanning Spreading Resistance Microscope  

SciTech Connect (OSTI)

Local resistance profiles of ultra shallow boron and arsenic implanted into silicon with energies of 2.0 and 4.0 keV and doses of 2.0x10{sup 15} and 1.0x10{sup 15} ions/cm{sup 2} activated by a combination of conventional spike lamp and laser annealing processes were measured by scanning spreading resistance microscope (SSRM) with a depth resolution of less than 10 nm. The lowest local resistance at the low resistance region in 2.0 keV boron implanted silicon with 1050 deg. C spike lamp annealing followed by 0.35 kW/mm{sup 2} laser annealing was half of that without laser annealing. The lowest local resistance at the low resistance region in the arsenic implanted silicon activated by 1050 deg. C spike lamp annealing followed by 0.39 kW/mm{sup 2} laser annealing was 74% lower than that followed by 0.36 kW/mm{sup 2} laser annealing. The lowest local resistances at the low resistance regions in the arsenic implanted silicon with 0.36 and 0.39 kW/mm{sup 2} laser annealing followed by 1050 deg. C spike lamp annealing were 41 and 33% lower than those with spike lamp annealing followed by laser annealing. Laser annealing followed by spike lamp annealing could suppress the diffusion of the impurities and was suitable for making the ultra shallow and low resistance regions.

Abo, Satoshi; Nishikawa, Kazuhisa; Ushigome, Naoya; Wakaya, Fujio; Takai, Mikio [Center for Quantum Science and Technology under Extreme Conditions, Osaka University, 1-3, Machikaneyama, Toyonaka, Osaka, 560-8531 (Japan); Iwamatsu, Toshiaki; Oda, Hidekazu [Advanced Device Technology Department, Production and Technology Unit, Devices and Analysis Technology Division, Renesas Electronics Corporation, 751, Horiguchi, Hitachinaka, Ibaraki, 312-8504 (Japan)

2011-01-07T23:59:59.000Z

262

ARM - Field Campaign - Water Vapor IOP  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

govCampaignsWater Vapor IOP govCampaignsWater Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Water Vapor IOP 1996.09.10 - 1996.09.30 Lead Scientist : Henry Revercomb For data sets, see below. Summary SCHEDULE This IOP will be conducted from September 10 - 30, 1996 (coincident with the Fall ARM-UAV IOP). Instruments that do not require supervision will be operated continuously during this period. Instruments that do require supervision are presently planned to be operated for 8-hour periods each day. Because it is necessary to cover as broad a range of environmental conditions as possible, the daily 8-hour period will be shifted across the diurnal cycle as deemed appropriate during the IOP (but will be maintained as a contiguous 8-hour block).

263

atmospheric water vapor | OpenEI  

Open Energy Info (EERE)

atmospheric water vapor atmospheric water vapor Dataset Summary Description (Abstract): Monthly Average Solar Resource for 2-axis tracking concentrating collectors for Mexico, Central America, and the Caribbean Islands. (Purpose): Provide information on the solar resource potential for the data domain. The insolation values represent the average solar energy available to a concentrating collector, such as a dish collector, which tracks the sun continuously. Source NREL Date Released July 31st, 2006 (8 years ago) Date Updated October 30th, 2007 (7 years ago) Keywords atmospheric water vapor Carribean Islands Central America DNI GIS Mexico NREL GEF solar SWERA UNEP Data application/zip icon Download Shapefile (zip, 247.8 KiB) text/csv icon Download Data (csv, 370.6 KiB) Quality Metrics Level of Review Some Review

264

atmoshperic water vapor | OpenEI  

Open Energy Info (EERE)

atmoshperic water vapor atmoshperic water vapor Dataset Summary Description (Abstract): Monthly Average Solar Resource for flat-plate collectors tilted at latitude for China. Source NREL Date Released April 12th, 2005 (9 years ago) Date Updated October 30th, 2007 (7 years ago) Keywords atmoshperic water vapor China GEF GIS NREL solar SWERA TILT UNEP Data application/zip icon Download Shapefile (zip, 625.6 KiB) text/csv icon Download Data (csv, 704.1 KiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Time Period 01/01/1985 - 12/31/1991 License License Open Data Commons Public Domain Dedication and Licence (PDDL) Comment Rate this dataset Usefulness of the metadata Average vote Your vote Usefulness of the dataset Average vote Your vote Ease of access

265

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

SciTech Connect (OSTI)

Creation of light for work, socializing, and general illumination is a fundamental application of technology around the world. For those who lack access to electricity, an emerging and diverse range of LED based lighting products hold promise for replacing and/or augmenting their current fuel-based lighting sources that are costly and dirty. Along with analysis of environmental factors, economic models for total cost-ofownership of LED lighting products are an important tool for studying the impacts of these products as they emerge in markets of developing countries. One important metric in those models is the minimum illuminance demanded by end-users for a given task before recharging the lamp or replacing batteries. It impacts the lighting service cost per unit time if charging is done with purchased electricity, batteries, or charging services. The concept is illustrated in figure 1: LED lighting products are generally brightest immediately after the battery is charged or replaced and the illuminance degrades as the battery is discharged. When a minimum threshold level of illuminance is reached, the operational time for the battery charge cycle is over. The cost to recharge depends on the method utilized; these include charging at a shop at a fixed price per charge, charging on personal grid connections, using solar chargers, and purchasing dry cell batteries. This Research Note reports on the observed"charge-triggering" illuminance level threshold for night market vendors who use LED lighting products to provide general and task oriented illumination. All the study participants charged with AC power, either at a fixed-price charge shop or with electricity at their home.

Johnstone, Peter; Jacobson, Arne; Mills, Evan; Radecsky, Kristen

2009-03-21T23:59:59.000Z

266

Vapor characterization of Tank 241-C-103  

SciTech Connect (OSTI)

The Westinghouse Hanford Company Tank Vapor Issue Resolution Program has developed, in cooperation with Northwest Instrument Systems, Inc., Oak Ridge National Laboratory, Oregon Graduate Institute of Science and Technology, Pacific Northwest Laboratory, and Sandia National Laboratory, the equipment and expertise to characterize gases and vapors in the high-level radioactive waste storage tanks at the Hanford Site in south central Washington State. This capability has been demonstrated by the characterization of the tank 241-C-103 headspace. This tank headspace is the first, and for many reasons is expected to be the most problematic, that will be characterized (Osborne 1992). Results from the most recent and comprehensive sampling event, sample job 7B, are presented for the purpose of providing scientific bases for resolution of vapor issues associated with tank 241-C-103. This report is based on the work of Clauss et al. 1994, Jenkins et al. 1994, Ligotke et al. 1994, Mahon et al. 1994, and Rasmussen and Einfeld 1994. No attempt has been made in this report to evaluate the implications of the data presented, such as the potential impact of headspace gases and vapors to tank farm workers health. That and other issues will be addressed elsewhere. Key to the resolution of worker health issues is the quantitation of compounds of toxicological concern. The Toxicology Review Panel, a panel of Pacific Northwest Laboratory experts in various areas, of toxicology, has chosen 19 previously identified compounds as being of potential toxicological concern. During sample job 7B, the sampling and analytical methodology was validated for this preliminary list of compounds of toxicological concern. Validation was performed according to guidance provided by the Tank Vapor Conference Committee, a group of analytical chemists from academic institutions and national laboratories assembled and commissioned by the Tank Vapor Issue Resolution Program.

Huckaby, J.L. [Westinghouse Hanford Co., Richland, WA (United States); Story, M.S. [Northwest Instrument Systems, Inc. Richland, WA (United States)

1994-06-01T23:59:59.000Z

267

Thermal electric vapor trap arrangement and method  

DOE Patents [OSTI]

A technique for trapping vapor within a section of a tube is disclosed herein. This technique utilizes a conventional, readily providable thermal electric device having a hot side and a cold side and means for powering the device to accomplish this. The cold side of this device is positioned sufficiently close to a predetermined section of the tube and is made sufficiently cold so that any condensable vapor passing through the predetermined tube section is condensed and trapped, preferably within the predetermined tube section itself. 4 figs.

Alger, T.

1988-03-15T23:59:59.000Z

268

Diode pumped alkali vapor fiber laser  

DOE Patents [OSTI]

A method and apparatus is provided for producing near-diffraction-limited laser light, or amplifying near-diffraction-limited light, in diode pumped alkali vapor photonic-band-gap fiber lasers or amplifiers. Laser light is both substantially generated and propagated in an alkali gas instead of a solid, allowing the nonlinear and damage limitations of conventional solid core fibers to be circumvented. Alkali vapor is introduced into the center hole of a photonic-band-gap fiber, which can then be pumped with light from a pump laser and operated as an oscillator with a seed beam, or can be configured as an amplifier.

Payne, Stephen A. (Castro Valley, CA); Beach, Raymond J. (Livermore, CA); Dawson, Jay W. (Livermore, CA); Krupke, William F. (Pleasanton, CA)

2006-07-26T23:59:59.000Z

269

Diode pumped alkali vapor fiber laser  

DOE Patents [OSTI]

A method and apparatus is provided for producing near-diffraction-limited laser light, or amplifying near-diffraction-limited light, in diode pumped alkali vapor photonic-band-gap fiber lasers or amplifiers. Laser light is both substantially generated and propagated in an alkali gas instead of a solid, allowing the nonlinear and damage limitations of conventional solid core fibers to be circumvented. Alkali vapor is introduced into the center hole of a photonic-band-gap fiber, which can then be pumped with light from a pump laser and operated as an oscillator with a seed beam, or can be configured as an amplifier.

Payne, Stephen A. (Castro Valley, CA); Beach, Raymond J. (Livermore, CA); Dawson, Jay W. (Livermore, CA); Krupke, William F. (Pleasanton, CA)

2007-10-23T23:59:59.000Z

270

Data:D905872b-352a-4ed8-a723-ea5cdb786d8a | Open Energy Information  

Open Energy Info (EERE)

b-352a-4ed8-a723-ea5cdb786d8a b-352a-4ed8-a723-ea5cdb786d8a No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Ocmulgee Electric Member Corp Effective date: 1999/05/01 End date if known: Rate name: 150W Type -'HPS-Sidelite', kWh-60 Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Corporation's specifications. Service will be rendered only at locations that, solely in the opinion of the Corporation, are readily accessible for installation and maintenance. Source or reference: ISU Documentation

271

Data:1373f291-f0ee-45f7-8abb-710bcedb969b | Open Energy Information  

Open Energy Info (EERE)

f0ee-45f7-8abb-710bcedb969b f0ee-45f7-8abb-710bcedb969b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Ocmulgee Electric Member Corp Effective date: 1999/05/01 End date if known: Rate name: 250W Type -'HPS-Flood', kWh-100 Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Corporation's specifications. Service will be rendered only at locations that, solely in the opinion of the Corporation, are readily accessible for installation and maintenance. Source or reference: ISU Documentation

272

Data:361821e3-113c-4a40-a9b1-becf02d08bae | Open Energy Information  

Open Energy Info (EERE)

e3-113c-4a40-a9b1-becf02d08bae e3-113c-4a40-a9b1-becf02d08bae No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Colquitt Electric Membership Corp Effective date: 1993/06/01 End date if known: Rate name: 150W Existing HPS-Cobra, UNDERGROUND WIRING, Metal or Fiberglass Pole Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW):

273

Data:3ae057df-d560-421f-a823-9f083fbaf24e | Open Energy Information  

Open Energy Info (EERE)

57df-d560-421f-a823-9f083fbaf24e 57df-d560-421f-a823-9f083fbaf24e No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Colquitt Electric Membership Corp Effective date: 1993/06/01 End date if known: Rate name: 175W Existing MV-Open, OVERHEAD WIRING, Wood Pole Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Source or reference: ISU Documentation Source Parent: Comments Not available for new installations after April 1, 1984. Additional $1.50 will be charged for mounted on 30 foot wood pole

274

Data:C251fa67-9544-43dd-8774-478976beffc5 | Open Energy Information  

Open Energy Info (EERE)

fa67-9544-43dd-8774-478976beffc5 fa67-9544-43dd-8774-478976beffc5 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Ocmulgee Electric Member Corp Effective date: 1999/05/01 End date if known: Rate name: 400W Type -'HPS-Open/Cobra' Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Corporation's specifications. Service will be rendered only at locations that, solely in the opinion of the Corporation, are readily accessible for installation and maintenance. Source or reference: ISU Documentation

275

Data:F6c81748-c99d-473d-9bb0-8b34f12f6580 | Open Energy Information  

Open Energy Info (EERE)

-c99d-473d-9bb0-8b34f12f6580 -c99d-473d-9bb0-8b34f12f6580 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Ocmulgee Electric Member Corp Effective date: 1999/05/01 End date if known: Rate name: 250W Type -'HPS-Open/Cobra', kWh-100 Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Corporation's specifications. Service will be rendered only at locations that, solely in the opinion of the Corporation, are readily accessible for installation and maintenance. Source or reference: ISU Documentation

276

Data:Def7b2f6-1ad6-43cc-b7fd-cd187ca97229 | Open Energy Information  

Open Energy Info (EERE)

f6-1ad6-43cc-b7fd-cd187ca97229 f6-1ad6-43cc-b7fd-cd187ca97229 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Colquitt Electric Membership Corp Effective date: 1993/06/01 End date if known: Rate name: 100W Existing HPS-Open, OVERHEAD WIRING, Metal or Fiberglass Pole Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months):

277

Data:653f2c78-bc47-49c7-bdd9-d4c8e8eb7a19 | Open Energy Information  

Open Energy Info (EERE)

c78-bc47-49c7-bdd9-d4c8e8eb7a19 c78-bc47-49c7-bdd9-d4c8e8eb7a19 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Ocmulgee Electric Member Corp Effective date: 1999/05/01 End date if known: Rate name: 175W Type -'MV-Open', kWh-70 Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Corporation's specifications. Service will be rendered only at locations that, solely in the opinion of the Corporation, are readily accessible for installation and maintenance. Source or reference: ISU Documentation

278

Data:7e93c11b-775f-465e-9235-9ddca638a215 | Open Energy Information  

Open Energy Info (EERE)

1b-775f-465e-9235-9ddca638a215 1b-775f-465e-9235-9ddca638a215 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Colquitt Electric Membership Corp Effective date: 1993/06/01 End date if known: Rate name: 150W Existing HPS-Cobra, OVERHEAD WIRING, Wood Pole Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Source or reference: ISU Documentation Source Parent: Comments Additional $1.50 will be charged for mounted on 30 foot wood pole Applicability

279

Data:Bd229c1e-67e3-4b51-b72b-25179dcb22ac | Open Energy Information  

Open Energy Info (EERE)

Bd229c1e-67e3-4b51-b72b-25179dcb22ac Bd229c1e-67e3-4b51-b72b-25179dcb22ac No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Ocmulgee Electric Member Corp Effective date: 1999/05/01 End date if known: Rate name: 1000W Type -'MH-Flood', kWh-500 Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Corporation's specifications. Service will be rendered only at locations that, solely in the opinion of the Corporation, are readily accessible for installation and maintenance.

280

Data:51533f61-6dd5-42c9-be64-0463d5f141db | Open Energy Information  

Open Energy Info (EERE)

-6dd5-42c9-be64-0463d5f141db -6dd5-42c9-be64-0463d5f141db No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Colquitt Electric Membership Corp Effective date: 1993/06/01 End date if known: Rate name: 175W Existing MV-Open, UNDERGROUND WIRING, Wood Pole Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Source or reference: ISU Documentation Source Parent: Comments Lighting mounted on 30 foot wood pole Applicability Demand (kW) Minimum (kW):

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Data:515de3b2-c165-4c4c-9d32-349a503492a7 | Open Energy Information  

Open Energy Info (EERE)

b2-c165-4c4c-9d32-349a503492a7 b2-c165-4c4c-9d32-349a503492a7 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Colquitt Electric Membership Corp Effective date: 1993/06/01 End date if known: Rate name: 1000W Existing MH-Flood, OVERHEAD WIRING, Wood Pole Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Source or reference: ISU Documentation Source Parent: Comments Additional $1.50 will be charged for mounted on 30 foot wood pole Applicability

282

Data:4ec729e0-aec3-4564-a4a8-dab996005797 | Open Energy Information  

Open Energy Info (EERE)

aec3-4564-a4a8-dab996005797 aec3-4564-a4a8-dab996005797 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Ocmulgee Electric Member Corp Effective date: 1999/05/01 End date if known: Rate name: 100W Type -'HPS-Open', kWh-40 Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Corporation's specifications. Service will be rendered only at locations that, solely in the opinion of the Corporation, are readily accessible for installation and maintenance. Source or reference: ISU Documentation

283

Data:9859aa63-0c3f-4c01-8e4c-e2eb958b89df | Open Energy Information  

Open Energy Info (EERE)

0c3f-4c01-8e4c-e2eb958b89df 0c3f-4c01-8e4c-e2eb958b89df No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Ocmulgee Electric Member Corp Effective date: 1999/05/01 End date if known: Rate name: 250W Type -'HPS-Flood', kWh-Metered Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Corporation's specifications. Service will be rendered only at locations that, solely in the opinion of the Corporation, are readily accessible for installation and maintenance. Source or reference: ISU Documentation

284

Data:D2ef18c1-d6bd-4a8f-accc-deb2cd0d7e93 | Open Energy Information  

Open Energy Info (EERE)

8c1-d6bd-4a8f-accc-deb2cd0d7e93 8c1-d6bd-4a8f-accc-deb2cd0d7e93 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Colquitt Electric Membership Corp Effective date: 1993/06/01 End date if known: Rate name: 100W Existing HPS-Open, OVERHEAD WIRING, Wood Pole Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Source or reference: ISU Documentation Source Parent: Comments Additional $1.50 will be charged for mounted on 30 foot wood pole Applicability

285

Data:7d97de30-230e-4b2f-8e91-abbd647e170c | Open Energy Information  

Open Energy Info (EERE)

0-230e-4b2f-8e91-abbd647e170c 0-230e-4b2f-8e91-abbd647e170c No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Ocmulgee Electric Member Corp Effective date: 1999/05/01 End date if known: Rate name: 250W Type -'HPS-Open/Cobra', kWh-Metered Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Corporation's specifications. Service will be rendered only at locations that, solely in the opinion of the Corporation, are readily accessible for installation and maintenance.

286

Data:Ef128562-8ee4-4ab9-9f47-8beedba3b42c | Open Energy Information  

Open Energy Info (EERE)

2-8ee4-4ab9-9f47-8beedba3b42c 2-8ee4-4ab9-9f47-8beedba3b42c No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Colquitt Electric Membership Corp Effective date: 1993/06/01 End date if known: Rate name: 175W Existing MV-Open, UNDERGROUND WIRING, Metal or Fiberglass Pole Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months):

287

Data:F2261ff3-3f9a-4c89-bddd-bd9f9f141a18 | Open Energy Information  

Open Energy Info (EERE)

ff3-3f9a-4c89-bddd-bd9f9f141a18 ff3-3f9a-4c89-bddd-bd9f9f141a18 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Ocmulgee Electric Member Corp Effective date: 1999/05/01 End date if known: Rate name: 400W Type -'HPS-Open/Cobra', kWh-160 Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Corporation's specifications. Service will be rendered only at locations that, solely in the opinion of the Corporation, are readily accessible for installation and maintenance.

288

Data:08944301-8344-4cae-9c5f-4c64c872f0ec | Open Energy Information  

Open Energy Info (EERE)

8344-4cae-9c5f-4c64c872f0ec 8344-4cae-9c5f-4c64c872f0ec No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Ocmulgee Electric Member Corp Effective date: 1999/05/01 End date if known: Rate name: 100W Type -'HPS-Open', kWh-Metered Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Corporation's specifications. Service will be rendered only at locations that, solely in the opinion of the Corporation, are readily accessible for installation and maintenance. Source or reference: ISU Documentation

289

Data:46508929-c87a-4a1a-ba7e-719d960b69d7 | Open Energy Information  

Open Energy Info (EERE)

-c87a-4a1a-ba7e-719d960b69d7 -c87a-4a1a-ba7e-719d960b69d7 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Colquitt Electric Membership Corp Effective date: 1993/06/01 End date if known: Rate name: 100W Existing HPS-Open, UNDERGROUND WIRING, Metal or Fiberglass Pole Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months):

290

Data:2306b541-b9e7-4cbf-997f-cc35f2517ba6 | Open Energy Information  

Open Energy Info (EERE)

41-b9e7-4cbf-997f-cc35f2517ba6 41-b9e7-4cbf-997f-cc35f2517ba6 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Colquitt Electric Membership Corp Effective date: 1993/06/01 End date if known: Rate name: 175W Existing MV-Open, OVERHEAD WIRING, Metal or Fiberglass Pole Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months):

291

Environmental Chemistry at Vapor/Water Interfaces  

E-Print Network [OSTI]

Environmental Chemistry at Vapor/Water Interfaces: Insights from Vibrational Sum Frequency Generation Spectroscopy Aaron M. Jubb, Wei Hua, and Heather C. Allen Department of Chemistry, The Ohio State/0505-0107$20.00 Keywords salts, lipids, atmospheric chemistry, ion binding, oxidation Abstract The chemistry that occurs

292

Advancing Explosives Detection Capabilities: Vapor Detection  

ScienceCinema (OSTI)

A new, PNNL-developed method provides direct, real-time detection of trace amounts of explosives such as RDX, PETN and C-4. The method selectively ionizes a sample before passing the sample through a mass spectrometer to detect explosive vapors. The method could be used at airports to improve aviation security.

Atkinson, David

2014-07-24T23:59:59.000Z

293

Program performs vapor-liquid equilibrium calculations  

SciTech Connect (OSTI)

A program designed for the Hewlett-Packard HP-41CV or 41C calculators solves basic vapor-liquid equilibrium problems, including figuring the dewpoint, bubblepoint, and equilibrium flash. The algorithm uses W.C. Edmister's method for predicting ideal-solution K values.

Rice, V.L.

1982-06-28T23:59:59.000Z

294

Synchroton X-Ray Studies of Liquid-Vapor Interfaces  

Science Journals Connector (OSTI)

The variation of density across the liquid-vapor interface from essentially zero density far out in the vapor phase to a homogeneous density deep in the liquid phase can be determined by X-ray reflectivity mea...

J. Als-Nielsen

1988-01-01T23:59:59.000Z

295

Vapor intrusion modeling : limitations, improvements, and value of information analyses  

E-Print Network [OSTI]

Vapor intrusion is the migration of volatile organic compounds (VOCs) from a subsurface source into the indoor air of an overlying building. Vapor intrusion models, including the Johnson and Ettinger (J&E) model, can be ...

Friscia, Jessica M. (Jessica Marie)

2014-01-01T23:59:59.000Z

296

Estimating the Atmospheric Water Vapor Content from Sun Photometer Measurements  

Science Journals Connector (OSTI)

The differential absorption technique for estimating columnar water vapor values from the analysis of sunphotometric measurements with wide- and narrowband interferential filters centered near 0.94 ?m is discussed and adapted. Water vapor line ...

Artemio Plana-Fattori; Michel Legrand; Didier Tanré; Claude Devaux; Anne Vermeulen; Philippe Dubuisson

1998-08-01T23:59:59.000Z

297

OPTIMIZATION OF INJECTION INTO VAPOR-DOMINATED GEOTHERMAL  

E-Print Network [OSTI]

given by U.S. Department of Energy, Geothermal Division. #12;vii Table of Contents ABSTRACTOPTIMIZATION OF INJECTION INTO VAPOR-DOMINATED GEOTHERMAL RESERVOIRS CONSIDERING ADSORPTION governing the behavior of vapor- dominated geothermal reservoirs. These mechanisms affect both

Stanford University

298

Spatial and time-dependent distribution of plasma parameters in the metal-halide arc lamp  

E-Print Network [OSTI]

It was shown by several authors that closed high pressure arc a.c. discharge in mercury vapors with addition of metal halide cannot be described in frames of the local thermodynamic equilibrium (LTE) model. However some plasma parameters (electron and high lying excited states densities as well as Hg metastable levels densities) are assumed to be in equilibrium with electron temperature and these assumptions are applied in plasma diagnostics. To verify these supposition the method of local plasma spectroscopy based on spatial and temporal distribution of spectral line profiles was developed. The experimental set up is based on diffraction spectrometer with large aperture, spatial scanning device and photodetector, which allows to carry out the measurements in chosen phases of current period. The software for data acquisition and processing is based on LabVIEW system. The original method of joint data processing was applied to data arrays containing spatial, spectral and temporal distribution of a source surfa...

Khakhaev, A; Ekimov, K; Soloviev, A; Khakhaev, Anatoly; Luizova, Lidia; Ekimov, Konstantin; Soloviev, Alexey

2004-01-01T23:59:59.000Z

299

Glass and glass-derivative seals for use in energy-efficient fuel cells and lamps  

SciTech Connect (OSTI)

For solid oxide fuel cells (SOFC), a series of 18 sealing glasses have been prepared and characterized. From the whole design space, several glasses were ''downselected'' and studied in detail to describe their behaviors in simulated fuel cell environments. One of the glasses was found to outperform all others, including the well-known G18 sealant developed at Pacific Northwest National Laboratory. The new glass composition showed lower bulk electrical conductivity, excellent sealing and wetting behavior when sealing under applied load, and qualitatively superior performance when exposed to wet hydrogen for 800 hours. Traditional melting was used to prepare all of the glasses that were studied in detail. The sol-gel approach was used to synthesize several compositions, but it was found that the glasses crystallized very rapidly during heating, precluding sealing. The glass characterization included measurements of the viscosity and thermal expansion of the glasses, as well as the thermal expansion of the partly crystalline glass ceramics. In addition, the wetting and sintering behavior of all glasses has been measured, as well as the crystallization behavior. The time and temperature at which crystalline phases form from the glasses has been determined for all of the glasses. Each glass ceramic contains at least two crystalline phases, and most of the crystalline phases have been positively identified. The body of fundamental data provides a platform for future developments for high temperature sealants, and the newly-developed glass compositions appear promising for large-scale testing. The second component of the work, focused on seals for higher-temperature discharge lighting, has focused on determining the phase relations in the yttria-alumina-silica system at various silica levels. Functional testing of one of the candidate sealants demonstrated that it performs well in current HID lighting applications. Further testing is required to evaluate its performance in next-generation lamps that operate at higher temperatures, but the baseline phase equilibria and crystallization behavior has been established for additional development. Again, traditional melting and sol-gel synthesis have been employed, and the sol-gel method was successful for preparing new phases that were discovered during the work. Four new phases have been identified and synthesized in pure form, from which full structure solutions were obtained as well as the anisotropic thermal expansion for each phase.

Scott Misture; Arun Varshineya; Matthew Hall; Sylvia DeCarr; Steve Bancheri

2005-07-28T23:59:59.000Z

300

Apparent Temperature Dependence on Localized Atmospheric Water Vapor  

E-Print Network [OSTI]

Apparent Temperature Dependence on Localized Atmospheric Water Vapor Matthew Montanaroa, Carl), hence water vapor is the primary constituent of concern. The tower generates a localized water vapor, Office B108, Aiken, SC, USA ABSTRACT The atmosphere is a critical factor in remote sensing. Radiance from

Salvaggio, Carl

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Potential Environmental Impacts from the Metals in Incandescent, Compact Fluorescent Lamp (CFL), and Light-Emitting Diode (LED) Bulbs  

Science Journals Connector (OSTI)

Artificial lighting systems are transitioning from incandescent to compact fluorescent lamp (CFL) and light-emitting diode (LED) bulbs in response to the U.S. Energy Independence and Security Act and the EU Ecodesign Directive, which leads to energy savings and reduced greenhouse gas emissions. ... The CFLs and LEDs have higher resource depletion and toxicity potentials than the incandescent bulb due primarily to their high aluminum, copper, gold, lead, silver, and zinc. ... mercury pollution; redn. in electricity demand from the substitution of incandescent bulbs with fluorescents leads to reduced mercury emissions during the use of the bulb. ...

Seong-Rin Lim; Daniel Kang; Oladele A. Ogunseitan; Julie M. Schoenung

2012-12-13T23:59:59.000Z

302

2014-05-05 Issuance: Test Procedures for High-Intensity Discharge Lamps; Supplemental Notice of Proposed Rulemaking  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register supplemental notice of proposed rulemaking regarding test procedures for high-intesity discharge lamps, as issued by the Deputy Assistant Secretary for Energy Efficiency on May 5, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

303

2015-01-26 Issuance: Energy Conservation Standards for General Service Lamps; Extension of Public Comment Period  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register extension of comment period regarding energy conservation standards for general service lamps, as issued by the Deputy Assistant Secretary for Energy Efficiency on January 26, 2015. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

304

Advanced Membrane Systems: Recovering Wasteful and Hazardous Fuel Vapors at the Gasoline Tank  

Broader source: Energy.gov [DOE]

Case study covering Compact Membrane Systems, Inc. and its membrane vapor processor that recovers fuel vapors from gasoline refueling.

305

Precision micro drilling with copper vapor lasers  

SciTech Connect (OSTI)

The authors have developed a copper vapor laser based micro machining system using advanced beam quality control and precision wavefront tilting technologies. Micro drilling has been demonstrated through percussion drilling and trepanning using this system. With a 30 W copper vapor laser running at multi-kHz pulse repetition frequency, straight parallel holes with size varying from 500 microns to less than 25 microns and with aspect ratio up to 1:40 have been consistently drilled on a variety of metals with good quality. For precision trepanned holes, the hole-to-hole size variation is typically within 1% of its diameter. Hole entrance and exit are both well defined with dimension error less than a few microns. Materialography of sectioned holes shows little (sub-micron scale) recast layer and heat affected zone with surface roughness within 1--2 microns.

Chang, J.J.; Martinez, M.W.; Warner, B.E.; Dragon, E.P.; Huete, G.; Solarski, M.E.

1994-09-02T23:59:59.000Z

306

Copper vapor laser modular packaging assembly  

DOE Patents [OSTI]

A modularized packaging arrangement for one or more copper vapor lasers and associated equipment is disclosed herein. This arrangement includes a single housing which contains the laser or lasers and all their associated equipment except power, water and neon, and means for bringing power, water, and neon which are necessary to the operation of the lasers into the container for use by the laser or lasers and their associated equipment.

Alger, Terry W. (Tracy, CA); Ault, Earl R. (Dublin, CA); Moses, Edward I. (Castro Valley, CA)

1992-01-01T23:59:59.000Z

307

ARM - Field Campaign - Fall 1997 Water Vapor IOP  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Water Vapor IOP Water Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Fall 1997 Water Vapor IOP 1997.09.15 - 1997.10.05 Lead Scientist : Henry Revercomb For data sets, see below. Summary The Water Vapor IOP was conducted as a follow-up to a predecessor IOP on water vapor held in September 1996. This IOP relied heavily on both ground-based guest and CART instrumentation and in-situ aircraft and tethered sonde/kite measurements. Primary operational hours were from 6 p.m. Central until at least midnight, with aircraft support normally from about 9 p.m. until midnight when available. However, many daytime measurements were made to support this IOP. The first Water Vapor IOP primarily concentrated on the atmosphere's lowest

308

G-Band Vapor Radiometer Profiler (GVRP) Handbook  

SciTech Connect (OSTI)

The G-Band Vapor Radiometer Profiler (GVRP) provides time-series measurements of brightness temperatures from 15 channels between 170 and 183.310 GHz. Atmospheric emission in this spectral region is primarily due to water vapor, with some influence from liquid water. Channels between 170.0 and 176.0 GHz are particularly sensitive to the presence of liquid water. The sensitivity to water vapor of the 183.31-GHz line is approximately 30 times higher than at the frequencies of the two-channel microwave radiometer (MWR) for a precipitable water vapor (PWV) amount of less than 2.5 mm. Measurements from the GVRP instrument are therefore especially useful during low-humidity conditions (PWV < 5 mm). In addition to integrated water vapor and liquid water, the GVRP can provide low-resolution vertical profiles of water vapor in very dry conditions.

Caddeau, MP

2010-06-23T23:59:59.000Z

309

A numerical study of the supply mode effects on high-pressure mercury discharge lamp dynamic thermal behavior  

SciTech Connect (OSTI)

This paper presents a numerical study of the dynamic behavior of high-pressure mercury discharge lamp as a function of supply mode. Bidimensional time-dependent equations have been solved by using a semi-implicit finite-element code. The model has been developed in the frame of the local thermodynamic equilibrium hypothesis. After validation by using experimental data from the literature, this model was applied to analyze the effects of some key parameters such as frequency for an ac arc current and the ratio cycle parameter for square arc-current wave form on the convective process. The results obtained have been used to analyze the dynamic thermal behavior of high-pressure mercury plasma (pressure equal to 0.3 MPa) working under currents widely different in frequency and wave form.

Kaziz, S.; Ahmed, R. Ben; Araoud, Z.; Gazzah, M.H.; Charrada, K.; Said, R. [EMIR, IPEIM, route de Skanes, 5019 Monastir (Tunisia); FSM, avenue de l'environnement, 5019 Monastir (Tunisia); EMIR, IPEIM, route de Skanes, 5019 Monastir (Tunisia)

2005-06-15T23:59:59.000Z

310

Vapor port and groundwater sampling well  

DOE Patents [OSTI]

A method and apparatus has been developed for combining groundwater monitoring wells with unsaturated-zone vapor sampling ports. The apparatus allows concurrent monitoring of both the unsaturated and the saturated zone from the same well at contaminated areas. The innovative well design allows for concurrent sampling of groundwater and volatile organic compounds (VOCs) in the vadose (unsaturated) zone from a single well, saving considerable time and money. The sample tubes are banded to the outer well casing during installation of the well casing.

Hubbell, Joel M. (Idaho Falls, ID); Wylie, Allan H. (Idaho Falls, ID)

1996-01-01T23:59:59.000Z

311

Chemical vapor deposition of epitaxial silicon  

DOE Patents [OSTI]

A single chamber continuous chemical vapor deposition (CVD) reactor is described for depositing continuously on flat substrates, for example, epitaxial layers of semiconductor materials. The single chamber reactor is formed into three separate zones by baffles or tubes carrying chemical source material and a carrier gas in one gas stream and hydrogen gas in the other stream without interaction while the wafers are heated to deposition temperature. Diffusion of the two gas streams on heated wafers effects the epitaxial deposition in the intermediate zone and the wafers are cooled in the final zone by coolant gases. A CVD reactor for batch processing is also described embodying the deposition principles of the continuous reactor.

Berkman, Samuel (Florham Park, NJ)

1984-01-01T23:59:59.000Z

312

Storing images in warm atomic vapor  

E-Print Network [OSTI]

Reversible and coherent storage of light in atomic medium is a key-stone of future quantum information applications. In this work, arbitrary two-dimensional images are slowed and stored in warm atomic vapor for up to 30 $\\mu$s, utilizing electromagnetically induced transparency. Both the intensity and the phase patterns of the optical field are maintained. The main limitation on the storage resolution and duration is found to be the diffusion of atoms. A techniqueanalogous to phase-shift lithography is employed to diminish the effect of diffusion on the visibility of the reconstructed image.

M. Shuker; O. Firstenberg; R. Pugatch; A. Ron; N. Davidson

2008-06-17T23:59:59.000Z

313

Recovery of benzene in an organic vapor monitor  

E-Print Network [OSTI]

solid adsorbents available (silica gel, activated alumina, etc. ), activated charcoal is most frequently utilized. Activated charcoal has retentivity for sorbed vapors several times that of silica gel and it displays a selectivity for organic vapors... (diffusion rate) of the vapor molecules to the sur- face of the adsorbent. The adsorption process determine how effective the adsorbent collects and holds the contam- inant on the surface of the activated charcoal. Recovery of the contaminant from...

Krenek, Gregory Joel

2012-06-07T23:59:59.000Z

314

Jade Sky Technologies Partners with CLTC on LED Replacement Lamp Upgrade Project UC Davis' California Lighting Technology Center will utilize Jade Sky Technologies' driver ICs to help spur  

E-Print Network [OSTI]

Jade Sky Technologies Partners with CLTC on LED Replacement Lamp Upgrade Project UC Davis of cost-effective, easy-to-use LED lighting solutions Milpitas, Calif. ­ October 15, 2013 ­ Jade Sky Technologies (JST), a clean-tech start-up manufacturer of driver ICs for LED lighting applications, announces

California at Davis, University of

315

Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) | Open Energy  

Open Energy Info (EERE)

Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) Exploration Activity Details Location Haleakala Volcano Area Exploration Technique Mercury Vapor Activity Date Usefulness not indicated DOE-funding Unknown Notes The field survey program on the northwest rift zone consisted of soil mercury and radon emanometry surveys, groundwater temperature and chemistry studies, Schlumberger resistivity soundings and self-potential profiles. Geophysical and geochemical surveys along this rift (southwest) were limited by difficult field conditions and access limitations. The geophysical program consisted of one Schlumberger sounding, one

316

Mercury Vapor At Vale Hot Springs Area (Varekamp & Buseck, 1983...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Vale Hot Springs Area (Varekamp & Buseck, 1983) Exploration Activity Details...

317

Mercury Vapor At Breitenbush Hot Springs Area (Varekamp & Buseck...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Breitenbush Hot Springs Area (Varekamp & Buseck, 1983) Exploration Activity...

318

Mercury Vapor At Mickey Hot Springs Area (Varekamp & Buseck,...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Mickey Hot Springs Area (Varekamp & Buseck, 1983) Exploration Activity...

319

Mercury Vapor At Desert Peak Area (Varekamp & Buseck, 1983) ...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Desert Peak Area (Varekamp & Buseck, 1983) Exploration Activity Details...

320

Mercury Vapor At Socorro Mountain Area (Kooten, 1987) | Open...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Socorro Mountain Area (Kooten, 1987) Exploration Activity Details Location...

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Mercury Vapor At Lassen Volcanic National Park Area (Varekamp...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Lassen Volcanic National Park Area (Varekamp & Buseck, 1983) Exploration...

322

Thermal Performance of a Double-Tube Type Lng Vaporizer  

Science Journals Connector (OSTI)

This report concerns the confirmed test results and method of analysis of the thermal performance of a double-tube type LNG vaporizer (DTV). The DTV is a...

Y. Miyata; T. Miura; S. Kasahara; H. Shohtani…

1994-01-01T23:59:59.000Z

323

Optimal Control of Vapor Extraction of Heavy Oil.  

E-Print Network [OSTI]

??Vapor extraction (Vapex) process is an emerging technology for viscous oil recovery that has gained much attention in the oil industry. However, the oil production… (more)

Muhamad, Hameed (Author)

2012-01-01T23:59:59.000Z

324

Geographic Information System At Cove Fort Area - Vapor (Nash...  

Open Energy Info (EERE)

navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Geographic Information System At Cove Fort Area - Vapor (Nash, Et Al., 2002) Exploration Activity Details...

325

Raman Lidar Measurements of Aerosols and Water Vapor During the...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

modifications reduced but could not eliminate these adverse effects. The Raman lidar water vapor (aerosol extinction) measurements produced by these modified algorithms were,...

326

Thermal Gradient Holes At Cove Fort Area - Vapor (Warpinski,...  

Open Energy Info (EERE)

Warpinski, Et Al., 2004) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Thermal Gradient Holes At Cove Fort Area - Vapor (Warpinski, Et Al.,...

327

Ground Magnetics At Cove Fort Area - Vapor (Warpinski, Et Al...  

Open Energy Info (EERE)

Vapor (Warpinski, Et Al., 2004) Exploration Activity Details Location Cove Fort Geothermal Area Exploration Technique Ground Magnetics Activity Date Usefulness useful DOE-funding...

328

Spray structures and vaporizing characteristics of a GDI fuel spray  

Science Journals Connector (OSTI)

The spray structures and distribution characteristics of liquid and vapor phases in non-evaporating and evaporating Gasoline Direct Injection (GDI) fuel sprays were investigated using Laser Induced...

Dong-Seok Choi; Gyung-Min Choi; Duck-Jool Kim

2002-07-01T23:59:59.000Z

329

Integration of Global Positioning System and Scanning Water Vapor Radiometers for Precipitable Water Vapor and Cloud Liquid Path Estimates  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Integration of Global Positioning System and Scanning Integration of Global Positioning System and Scanning Water Vapor Radiometers for Precipitable Water Vapor and Cloud Liquid Path Estimates V. Mattioli and P. Basili Department of Electronic and Information Engineering University of Perugia Perugia, Italy E. R. Westwater Cooperative Institute for Research in Environmental Sciences University of Colorado National Oceanic and Atmospheric Administration Environmental Technology Laboratory Boulder, Colorado Introduction In recent years the Global Positioning System (GPS) has proved to be a reliable instrument for measuring precipitable water vapor (PWV) (Bevis et al. 1992), offering an independent source of information on water vapor when compared with microwave radiometers (MWRs), and/or radiosonde

330

Vapor and gas sampling of Single-Shell Tank 241-T-111 using the vapor sampling system  

SciTech Connect (OSTI)

This document presents sampling data resulting from the January 20, 1995, sampling of SST 241-T-111 using the vapor sampling system.

Caprio, G.S.

1995-09-01T23:59:59.000Z

331

Vapor and gas sampling of single-shell tank 241-BY-112 using the vapor sampling system  

SciTech Connect (OSTI)

This document presents sampling data from the November 18, 1994, sampling of SST 241-BY-112 using the vapor sampling system.

Caprio, G.S.

1995-09-20T23:59:59.000Z

332

Informal Report . VAPOR DETECTION OF TRAFFICKING OF CONTRABAND MONEY-  

E-Print Network [OSTI]

I BNL- 62834 Informal Report . VAPOR DETECTION OF TRAFFICKING OF CONTRABAND MONEY-· [D VAPOR DETECTION OF TRAFFICKING OF CONTRABAND MONEY- A DISCUSSION OF TECHNICAL FEASIBILITY Concept MONEY --A DISCUSSION OF TECHNICAL FEASffiILITY Russell N. Dietz, Head Tracer Technology Center

333

RESONANT FARADAY ROTATION IN A HOT LITHIUM VAPOR  

E-Print Network [OSTI]

RESONANT FARADAY ROTATION IN A HOT LITHIUM VAPOR By SCOTT RUSSELL WAITUKAITIS A Thesis Submitted: #12;Abstract I describe a study of Faraday rotation in a hot lithium vapor. I begin by dis- cussing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.3 The Lithium Oven and Solenoid . . . . . . . . . . . . . . . . . 7 3 Theoretical Framework

Cronin, Alex D.

334

FLAMMABILITY CHARACTERISTICS OF COMBUSTIBLE GASES AND VAPORS  

Office of Scientific and Technical Information (OSTI)

Bulletin 627 Bulletin 627 BUREAU o b MINES FLAMMABILITY CHARACTERISTICS OF COMBUSTIBLE GASES AND VAPORS By Michael G. Zabetakis DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency Thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement,

335

New Regenerative Cycle for Vapor Compression Refrigeration  

Office of Scientific and Technical Information (OSTI)

SCIENTIFIC REPORT SCIENTIFIC REPORT Title Page Project Title: New Regenerative Cycle for Vapor Compression Refrigeration DOE Award Number: DE-FG36-04GO14327 Document Title: Final Scientific Report Period Covered by Report: September 30, 2004 to September 30, 2005 Name and Address of Recipient Organization: Magnetic Development, Inc., 68 Winterhill Road, Madison, CT 06443, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Contact Information: Mark J. Bergander, Ph.D., P.E., Principal Investigator, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Project Objective (as stated in the proposal): The main objective of this project is to confirm on a well-instrumented prototype the theoretically derived claims of higher efficiency and coefficient

336

Chemical vapor deposition of group IIIB metals  

DOE Patents [OSTI]

Coatings of Group IIIB metals and compounds thereof are formed by chemical vapor deposition, in which a heat decomposable organometallic compound of the formula given in the patent where M is a Group IIIB metal, such as lanthanum or yttrium and R is a lower alkyl or alkenyl radical containing from 2 to about 6 carbon atoms, with a heated substrate which is above the decomposition temperature of the organometallic compound. The pure metal is obtained when the compound of the formula 1 is the sole heat decomposable compound present and deposition is carried out under nonoxidizing conditions. Intermetallic compounds such as lanthanum telluride can be deposited from a lanthanum compound of formula 1 and a heat decomposable tellurium compound under nonoxidizing conditions.

Erbil, A.

1989-11-21T23:59:59.000Z

337

Kinetics of wet sodium vapor complex plasma  

SciTech Connect (OSTI)

In this paper, we have investigated the kinetics of wet (partially condensed) Sodium vapor, which comprises of electrons, ions, neutral atoms, and Sodium droplets (i) in thermal equilibrium and (ii) when irradiated by light. The formulation includes the balance of charge over the droplets, number balance of the plasma constituents, and energy balance of the electrons. In order to evaluate the droplet charge, a phenomenon for de-charging of the droplets, viz., evaporation of positive Sodium ions from the surface has been considered in addition to electron emission and electron/ion accretion. The analysis has been utilized to evaluate the steady state parameters of such complex plasmas (i) in thermal equilibrium and (ii) when irradiated; the results have been graphically illustrated. As a significant outcome irradiated, Sodium droplets are seen to acquire large positive potential, with consequent enhancement in the electron density.

Mishra, S. K., E-mail: nishfeb@rediffmail.com [Institute for Plasma Research (IPR), Gandhinagar 382428 (India); Sodha, M. S. [Centre of Energy Studies, Indian Institute of Technology Delhi (IITD), New Delhi 110016 (India)] [Centre of Energy Studies, Indian Institute of Technology Delhi (IITD), New Delhi 110016 (India)

2014-04-15T23:59:59.000Z

338

Gas Separation Using Organic-Vapor-Resistent Membranes In Conjunctin With Organic-Vapor-Selective Membranes  

DOE Patents [OSTI]

A process for treating a gas mixture containing at least an organic compound gas or vapor and a second gas, such as natural gas, refinery off-gas or air. The process uses two sequential membrane separation steps, one using membrane selective for the organic compound over the second gas, the other selective for the second gas over the organic vapor. The second-gas-selective membranes use a selective layer made from a polymer having repeating units of a fluorinated polymer, and demonstrate good resistance to plasticization by the organic components in the gas mixture under treatment, and good recovery after exposure to liquid aromatic hydrocarbons. The membrane steps can be combined in either order.

Baker, Richard W. (Palo Alto, CA); Pinnau, Ingo (Palo Alto, CA); He, Zhenjie (Fremont, CA); Da Costa, Andre R. (Menlo Park, CA); Daniels, Ramin (San Jose, CA); Amo, Karl D. (Mountain View, CA); Wijmans, Johannes G. (Menlo Park, CA)

2003-06-03T23:59:59.000Z

339

Hybrid Vapor Compression Adsorption System: Thermal Storage Using Hybrid Vapor Compression Adsorption System  

SciTech Connect (OSTI)

HEATS Project: UTRC is developing a new climate-control system for EVs that uses a hybrid vapor compression adsorption system with thermal energy storage. The targeted, closed system will use energy during the battery-charging step to recharge the thermal storage, and it will use minimal power to provide cooling or heating to the cabin during a drive cycle. The team will use a unique approach of absorbing a refrigerant on a metal salt, which will create a lightweight, high-energy-density refrigerant. This unique working pair can operate indefinitely as a traditional vapor compression heat pump using electrical energy, if desired. The project will deliver a hot-and-cold battery that provides comfort to the passengers using minimal power, substantially extending the driving range of EVs.

None

2012-01-04T23:59:59.000Z

340

E-Print Network 3.0 - atomic vapor laser Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

with the exception of pagination. IEEE TRANSACTIONS ON PLASMA SCIENCE 1 Summary: vapor, atomic physics and vapor ionization, absorption reflection in a heated plasma layer, and...

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

E-Print Network 3.0 - atom vapor cells Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

rotation in the vapor cell due to inten- sity-induced birefringence in the rubidium atomic vapor. While... Super efficient absorption filter for quantum memory using atomic...

342

Facility for high-heat flux testing of irradiated fusion materials and components using infrared plasma arc lamps  

Science Journals Connector (OSTI)

A new high-heat flux testing (HHFT) facility using water-wall stabilized high-power high-pressure argon plasma arc lamps (PALs) has been developed for fusion applications. It can accommodate irradiated plasma facing component materials and sub-size mock-up divertor components. Two PALs currently available at Oak Ridge National Laboratory can provide maximum incident heat fluxes of 4.2 and 27 MW m?2, which are prototypic of fusion steady state heat flux conditions, over a heated area of 9 ? 12 and 1 ? 10 cm2, respectively. The use of PAL permits the heat source to be environmentally separated from the components of the test chamber, simplifying the design to accommodate safe testing of low-level irradiated articles and materials under high-heat flux. Issues related to the operation and temperature measurements during testing of tungsten samples are presented and discussed. The relative advantages and disadvantages of this photon-based HHFT facility are compared to existing e-beam and particle beam facilities used for similar purposes.

Adrian S Sabau; Evan K Ohriner; Jim Kiggans; David C Harper; Lance L Snead; Charles R Schaich

2014-01-01T23:59:59.000Z

343

Facility for high heat flux testing of irradiated fusion materials and components using infrared plasma arc lamps  

SciTech Connect (OSTI)

A new high-heat flux testing facility using water-wall stabilized high-power high-pressure argon Plasma Arc Lamps (PALs) has been developed for fusion applications. It can handle irradiated plasma facing component materials and mock-up divertor components. Two PALs currently available at ORNL can provide maximum incident heat fluxes of 4.2 and 27 MW/m2 over a heated area of 9x12 and 1x10 cm2, respectively, which are fusion-prototypical steady state heat flux conditions. The facility will be described and the main differences between the photon-based high-heat flux testing facilities, such as PALs, and the e-beam and particle beam facilities more commonly used for fusion HHF testing are discussed. The components of the test chamber were designed to accommodate radiation safety and materials compatibility requirements posed by high-temperature exposure of low levels irradiated tungsten articles. Issues related to the operation and temperature measurements during testing are presented and discussed.

Sabau, Adrian S [ORNL] [ORNL; Ohriner, Evan Keith [ORNL] [ORNL; Kiggans, Jim [ORNL] [ORNL; Harper, David C [ORNL] [ORNL; Snead, Lance Lewis [ORNL] [ORNL; Schaich, Charles Ross [ORNL] [ORNL

2014-01-01T23:59:59.000Z

344

DOE CALiPER Program, Report 20.1 Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps  

SciTech Connect (OSTI)

This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members ranking of color quality did not always match the rank according to the color rendering index (CRI).

Royer, Michael P.; Poplawski, Michael E.; Miller, Naomi J.

2013-10-01T23:59:59.000Z

345

Results from the Carbon-Land Model Intercomparison Project (C-LAMP) and Availability of the Data on the Earth System Grid (ESG)  

SciTech Connect (OSTI)

This paper describes the Carbon-Land Model Intercomparison Project (C-LAMP) being carried out through a collaboration between the Community Climate System Model (CCSM) Biogeochemistry Working Group, a DOE SciDAC-2 project, and the DOE Program for Climate Model Diagnosis and Intercomparison (PCMDI). The goal of the project is to intercompare terrestrial biogeochemistry models running within the CCSM framework to determine the best set of processes to include in future versions of CCSM. As a part of the project, observational datasets are being collected and used to score the scientific performance of these models following a well-defined set of metrics. In addition, metadata standards for terrestrial biosphere models are being developed to support archival and distribution of the C-LAMP model output via the Earth System Grid (ESG). Progress toward completion of this project and preliminary results from the first set of experiments are reported.

Hoffman, Forrest M [ORNL; Covey, Curtis [Lawrence Livermore National Laboratory (LLNL); Fung, Inez [University of California, Berkeley; Randerson, Jim [University of California, Irvine; Thornton, Peter [National Center for Atmospheric Research (NCAR); Lee, Jeff [National Center for Atmospheric Research (NCAR); Rosenbloom, Nan [National Center for Atmospheric Research (NCAR); Stockli, Reto [Colorado State University, Fort Collins; Running, Steven [University of Montana, Missoula; Bernholdt, David E [ORNL; Williams, Dean [Lawrence Livermore National Laboratory (LLNL)

2007-01-01T23:59:59.000Z

346

DOE/EA-1664: Environmental Assessment for 10 CFR 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps (June 2009)  

Broader source: Energy.gov (indexed) [DOE]

4 4 Environmental Assessment for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps June 2009 16-i CHAPTER 16. ENVIRONMENTAL ASSESSMENT TABLE OF CONTENTS 16.1 INTRODUCTION ......................................................................................................... 16-1 16.2 AIR EMISSIONS ANALYSIS...................................................................................... 16-1 16.2.1 Air Emissions Descriptions............................................................................................ 16-1 16.2.2 Air Quality Regulation................................................................................................... 16-3 16.2.3 Global Climate Change..................................................................................................

347

Preliminary assessment of halogenated alkanes as vapor-phase tracers  

SciTech Connect (OSTI)

New tracers are needed to evaluate the efficiency of injection strategies in vapor-dominated environments. One group of compounds that seems to meet the requirements for vapor-phase tracing are the halogenated alkanes (HCFCs). HCFCs are generally nontoxic, and extrapolation of tabulated thermodynamic data indicate that they will be thermally stable and nonreactive in a geothermal environment. The solubilities and stabilities of these compounds, which form several homologous series, vary according to the substituent ratios of fluorine, chlorine, and hydrogen. Laboratory and field tests that will further define the suitability of HCFCs as vapor-phase tracers are under way.

Adams, Michael C.; Moore, Joseph N.; Hirtz, Paul

1991-01-01T23:59:59.000Z

348

Mercury Vapor At Medicine Lake Area (Kooten, 1987) | Open Energy  

Open Energy Info (EERE)

Kooten, 1987) Kooten, 1987) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Medicine Lake Area (Kooten, 1987) Exploration Activity Details Location Medicine Lake Area Exploration Technique Mercury Vapor Activity Date Usefulness could be useful with more improvements DOE-funding Unknown References Gerald K. Van Kooten (1987) Geothermal Exploration Using Surface Mercury Geochemistry Retrieved from "http://en.openei.org/w/index.php?title=Mercury_Vapor_At_Medicine_Lake_Area_(Kooten,_1987)&oldid=386431" Category: Exploration Activities What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation:

349

Catalytic Reactor For Oxidizing Mercury Vapor  

DOE Patents [OSTI]

A catalytic reactor (10) for oxidizing elemental mercury contained in flue gas is provided. The catalyst reactor (10) comprises within a flue gas conduit a perforated corona discharge plate (30a, b) having a plurality of through openings (33) and a plurality of projecting corona discharge electrodes (31); a perforated electrode plate (40a, b, c) having a plurality of through openings (43) axially aligned with the through openings (33) of the perforated corona discharge plate (30a, b) displaced from and opposing the tips of the corona discharge electrodes (31); and a catalyst member (60a, b, c, d) overlaying that face of the perforated electrode plate (40a, b, c) opposing the tips of the corona discharge electrodes (31). A uniformly distributed corona discharge plasma (1000) is intermittently generated between the plurality of corona discharge electrode tips (31) and the catalyst member (60a, b, c, d) when a stream of flue gas is passed through the conduit. During those periods when corona discharge (1000) is not being generated, the catalyst molecules of the catalyst member (60a, b, c, d) adsorb mercury vapor contained in the passing flue gas. During those periods when corona discharge (1000) is being generated, ions and active radicals contained in the generated corona discharge plasma (1000) desorb the mercury from the catalyst molecules of the catalyst member (60a, b, c, d), oxidizing the mercury in virtually simultaneous manner. The desorption process regenerates and activates the catalyst member molecules.

Helfritch, Dennis J. (Baltimore, MD)

1998-07-28T23:59:59.000Z

350

Laser techniques for studying chemical vapor deposition  

SciTech Connect (OSTI)

Chemical vapor deposition (CVD) is widely used to produce thin films for microelectronics, protective coatings and other materials processing applications. Despite the large number of applications, however, little is known about the fundamental chemistry and physics of most CVD processes. CVD recipes have generally been determined empirically, but as process requirements become more stringent, a more basic understanding will be needed to improve reactor design and speed process optimization. In situ measurements of the reacting gas are important steps toward gaining such an understanding, both from the standpoint of characterizing the reactor and testing models of a CVD process. Our work, a coordinated program of experimental and theoretical research in the fundamental mechanisms of CVD, illustrates the application of laser techniques to the understanding of a CVD system. We have used a number of laser-based techniques to probe CVD systems and have compared our measurements with predictions from computer models, primarily for the silane CVD system. The silane CVD model solves the two-dimensional, steady-state boundary layer equations of fluid flow coupled to 26 elementary chemical reactions describing the thermal decomposition of silane and the subsequent reactions of intermediate species that result in the deposition of a silicon film.

Ho, P.; Breiland, W.G.; Coltrin, M.E.

1990-01-01T23:59:59.000Z

351

ARM - Field Campaign - Arctic Winter Water Vapor IOP  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

govCampaignsArctic Winter Water Vapor IOP govCampaignsArctic Winter Water Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Arctic Winter Water Vapor IOP 2004.03.09 - 2004.04.09 Lead Scientist : Ed Westwater Data Availability http://www.etl.noaa.gov/programs/2004/wviop/data will contain quicklooks of all of the data. For data sets, see below. Summary During the IOP, the Ground-based Scanning Radiometer of NOAA/ETL, and the ARM MicroWave Radiometer and Microwave Profiler, yielded excellent data over a range of conditions. In all, angular-scanned and calibrated radiometric data from 22.345 to 380 GHz were taken. The Precipitable Water Vapor varied about an order of magnitude from 1 to 10 mm, and surface temperatures varied from about -10 to -40 deg. Celcius. Vaisala RS90

352

Overview of the ARM/FIRE Water Vapor Experiment (AFWEX)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Overview of the ARM/FIRE Water Vapor Overview of the ARM/FIRE Water Vapor Experiment (AFWEX) D. C. Tobin, H. E. Revercomb, and D. D. Turner University of Wisconsin-Madison Madison, Wisconsin Introduction An overview of the ARM/FIRE Water Vapor Experiment (AFWEX) is given. This field experiment was conducted during November-December 2000 near the central ground-based Atmospheric Radiation Measurement (ARM) site in north central Oklahoma, and was sponsored jointly by the ARM, the National Aeronautics and Space Administration (NASA) First ISCCP Regional Experiment (FIRE), and the National Polar-orbiting Operational Environmental Satellite System (NPOESS) programs. Its primary goal was to collect accurate measurements of upper-level (~8 to 12 km) water vapor near the ground-based ARM site. These data are being used to determine the accuracy of measurements that are

353

Initiated chemical vapor deposition of functional polyacrylic thin films  

E-Print Network [OSTI]

Initiated chemical vapor deposition (iCVD) was explored as a novel method for synthesis of functional polyacrylic thin films. The process introduces a peroxide initiator, which can be decomposed at low temperatures (<200?C) ...

Mao, Yu, 1975-

2005-01-01T23:59:59.000Z

354

Low Level Heat Recovery Through Heat Pumps and Vapor Recompression  

E-Print Network [OSTI]

The intent of this paper is to examine the methods and economics of recovering low level heat through heat pumps and vapor recompression. Actual commercially available equipment is considered to determine the near-term and future economic viability...

Gilbert, J.

1980-01-01T23:59:59.000Z

355

Applications of Mechanical Vapor Recompression to Evaporation and Crystallization  

E-Print Network [OSTI]

there is no boiler plant available or when electrical power is priced competitively in comparison to steam. Vapor recompression is accomplished using centrifugal, axial-flow, or positive displacement compressors and these compressors can be powered by electricity...

Outland, J. S.

356

Enabling integration of vapor-deposited polymer thin films  

E-Print Network [OSTI]

Initiated Chemical Vapor Deposition (iCVD) is a versatile, one-step process for synthesizing conformal and functional polymer thin films on a variety of substrates. This thesis emphasizes the development of tools to further ...

Petruczok, Christy D. (Christy Danielle)

2014-01-01T23:59:59.000Z

357

Hyperfine Studies of Lithium Vapor using Saturated Absorption Spectroscopy  

E-Print Network [OSTI]

the frequency of a laser with respect to an atomic spectral feature.[20] As such, saturated absorptionHyperfine Studies of Lithium Vapor using Saturated Absorption Spectroscopy? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 3.3 Broadening Mechanisms . . . . . . . . . . . . . . . . . . . . . 15 3.4 Saturated Absorption

Cronin, Alex D.

358

All graphene electromechanical switch fabricated by chemical vapor deposition  

E-Print Network [OSTI]

We demonstrate an electromechanical switch comprising two polycrystalline graphene films; each deposited using ambient pressure chemical vapor deposition. The top film is pulled into electrical contact with the bottom film ...

Milaninia, Kaveh M.

359

Systems and methods for generation of hydrogen peroxide vapor  

DOE Patents [OSTI]

A system according to one embodiment includes a moisture trap for drying air; at least one of a first container and a second container; and a mechanism for at least one of: bubbling dried air from the moisture trap through a hydrogen peroxide solution in the first container for producing a hydrogen peroxide vapor, and passing dried air from the moisture trap into a headspace above a hydrogen peroxide solution in the second container for producing a hydrogen peroxide vapor. A method according one embodiment includes at least one of bubbling dried air through a hydrogen peroxide solution in a container for producing a first hydrogen peroxide vapor, and passing dried air from the moisture trap into a headspace above the hydrogen peroxide solution in a container for producing a second hydrogen peroxide vapor. Additional systems and methods are also presented.

Love, Adam H; Eckels, Joel Del; Vu, Alexander K; Alcaraz, Armando; Reynolds, John G

2014-12-02T23:59:59.000Z

360

Optical Precursors in Rubidium Vapor and Their Relation to Superradiance  

E-Print Network [OSTI]

Optical precursor is the sharp optical pulse front that does not show delay in absorptive media. In this thesis, optical precursor behavior in rubidium (Rb) vapor was investigated in the picoseconds regime. An amplified femtosecond laser was shaped...

Yang, Wenlong

2012-10-19T23:59:59.000Z

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Photocoupling of Methane in Water Vapor to Saturated Hydrocarbons  

Science Journals Connector (OSTI)

Methane can be converted into alkanes (from C2 to C6) continuously by ultraviolet (185 nm) irradiation in the presence of water vapor. The products from this reaction are alkanes, which is different from the comp...

JunePyo Oh; Taketoshi Matsumoto; Junji Nakamura

2008-08-01T23:59:59.000Z

362

Mercury Vapor At Kawaihae Area (Thomas, 1986) | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor At Kawaihae Area (Thomas, 1986) Mercury Vapor At Kawaihae Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Kawaihae Area (Thomas, 1986) Exploration Activity Details Location Kawaihae Area Exploration Technique Mercury Vapor Activity Date Usefulness not useful DOE-funding Unknown Notes The soil geochemistry yielded quite complex patterns of mercury concentrations and radonemanation rates within the survey area (Cox and Cuff, 1981c). Mercury concentrations (Fig. 38) showed a general minimum along the Kawaihae-Waimea roads and a broad trend of increasing mercury concentrations toward both the north and south. There is no correlation apparent between the mercury patterns and either the resistivity sounding data or the surface geology in the area. The radon emanometry data (Fig.

363

Mercury Vapor At Lualualei Valley Area (Thomas, 1986) | Open Energy  

Open Energy Info (EERE)

Mercury Vapor At Lualualei Valley Area (Thomas, 1986) Mercury Vapor At Lualualei Valley Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Lualualei Valley Area (Thomas, 1986) Exploration Activity Details Location Lualualei Valley Area Exploration Technique Mercury Vapor Activity Date Usefulness useful DOE-funding Unknown Notes Soil mercury and radon emanation surveys were performed over much of the accessible surface of Lualualei Valley (Cox and Thomas, 1979). The results of these surveys (Figs 7 and 8) delineated several areas in which soil mercury concentrations or radon emanation rates were substantially above normal background values. Some of these areas were apparently coincident with the mapped fracture systems associated with the caldera boundaries.

364

Advanced Chemical Heat Pumps Using Liquid-Vapor Reactions  

E-Print Network [OSTI]

ically feasible systems have significant potential advantage over conventional tech nology. An electric drive reactive heat pump can use smaller heat exchangers and compressor than a vapor-compression machine, and have more flexible operating... are discussed, and performance is bounded. A discussion on liquid-vapor equilibria is included as introduction to the systems I- considered. The electric drive heat pump and TA are promising systems; the TA has potential for higher COP than absorption...

Kirol, L.

365

D/sup -/ production by charge transfer in metal vapors  

SciTech Connect (OSTI)

Fast D/sup -/ ions can be produced from D/sup +/ by multiple charge-transfer collisions in a metal-vapor target. Experimental cross sections and thick-target D/sup -/ yields are presented and discussed. The high D/sup -/ yield experimentally observed from charge transfer in cesium vapor is consistent with recent low-energy cross-section calculations and measurements.

Schlachter, A.S.

1980-10-01T23:59:59.000Z

366

Injection locked oscillator system for pulsed metal vapor lasers  

DOE Patents [OSTI]

An injection locked oscillator system for pulsed metal vapor lasers is disclosed. The invention includes the combination of a seeding oscillator with an injection locked oscillator (ILO) for improving the quality, particularly the intensity, of an output laser beam pulse. The present invention includes means for matching the first seeder laser pulses from the seeding oscillator to second laser pulses of a metal vapor laser to improve the quality, and particularly the intensity, of the output laser beam pulse.

Warner, Bruce E. (Livermore, CA); Ault, Earl R. (Dublin, CA)

1988-01-01T23:59:59.000Z

367

Tank 241-S-102 headspace gas and vapor characterization results for samples collected in March 1995  

SciTech Connect (OSTI)

Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

Huckaby, J.L. [Pacific Northwest Lab., Richland, WA (United States); Bratzel, D.R. [Westinghouse Hanford Co., Richland, WA (United States)

1995-09-26T23:59:59.000Z

368

investigating the source, transport, and isotope fractionation of water vapor in the atmospheric boundary layer  

E-Print Network [OSTI]

investigating the source, transport, and isotope fractionation of water vapor in the atmospheric cospectral similarity for temperature and water vapor isotope fluxes. mixing ratio generator Routine field use in water vapor isotope research. The unit generates a stable water vapor mixing ratio by measuring

Minnesota, University of

369

Calculating the vapor pressure of water from the second law of thermodynamics  

Science Journals Connector (OSTI)

Calculating the vapor pressure of water from the second law of thermodynamics ... Thermodynamics ...

M. H. Everdell

1969-01-01T23:59:59.000Z

370

The growth of vapor bubble and relaxation between two-phase bubble flow  

Science Journals Connector (OSTI)

This paper presents the behavior of the bubble growth and relaxation between vapor and superheated...

S. Mohammadein; Rama Subba Reddy Gorla

2003-01-01T23:59:59.000Z

371

Tank Vapor Characterization Project: Annual status report for FY 1996  

SciTech Connect (OSTI)

In Fiscal Year 1996, staff at the Vapor Analytical Laboratory at Pacific Northwest National Laboratory performed work in support of characterizing the vapor composition of the headspaces of radioactive waste tanks at the Hanford Site. Work performed included support for technical issues and sampling methodologies, upgrades for analytical equipment, analytical method development, preparation of unexposed samples, analyses of tank headspaces samples, preparation of data reports, and operation of the tank vapor database. Progress made in FY 1996 included completion and issuance of 50 analytical data reports. A sampling system comparison study was initiated and completed during the fiscal year. The comparison study involved the vapor sampling system (VSS), a truck-based system, and the in situ vapor sampling system (ISVS), a cart-based system. Samples collected during the study were characterized for inorganic, permanent gases, total non-methane organic compounds and organic speciation by SUMMA{trademark} and TST methods. The study showed comparable sampling results between the systems resulting in the program switching from the VSS to the less expensive ISVS methodology in late May 1996. A temporal study was initiated in January 1996 in order to understand the influences seasonal temperatures changes have on the vapors in the headspace of Hanford waste tanks. A holding time study was initiated in the fourth quarter of FY 1996. Samples were collected from tank S-102 and rushed to the laboratory for time zero analysis. Additional samples will be analyzed at 1, 2, 4, 8, 16, and 32 weeks.

Silvers, K.L.; Fruchter, J.S.; Huckaby, J.L.; Almeida, T.L.; Evans, J.C. Jr.; Pool, K.H.; Simonen, C.A.; Thornton, B.M.

1997-01-01T23:59:59.000Z

372

Data:81d91b19-1a87-4a5b-8715-5651a041a938 | Open Energy Information  

Open Energy Info (EERE)

1b19-1a87-4a5b-8715-5651a041a938 1b19-1a87-4a5b-8715-5651a041a938 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Columbia River Peoples Ut Dist Effective date: 2011/10/01 End date if known: Rate name: Outdoor Area Lighting 250w Sodium Vapor Flood Light Style Sector: Lighting Description: Applicability To outdoor area lighting service on Customer property. Character of Service Lighting service from dusk to dawn daily, by means of PUD-owned luminaries mounted on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably possible after notification by the Customer and subject to the PUD's operating schedules and requirements.

373

Data:56e44dc6-465e-4aae-af68-4af7ee096040 | Open Energy Information  

Open Energy Info (EERE)

e44dc6-465e-4aae-af68-4af7ee096040 e44dc6-465e-4aae-af68-4af7ee096040 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Columbia River Peoples Ut Dist Effective date: 2011/10/01 End date if known: Rate name: Outdoor Area Lighting 100w Sodium Vapor Area Light Style Sector: Lighting Description: Applicability To outdoor area lighting service on Customer property. Character of Service Lighting service from dusk to dawn daily, by means of PUD-owned luminaries mounted on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably possible after notification by the Customer and subject to the PUD's operating schedules and requirements.

374

Data:2b347101-f363-4d6c-ba46-1ad209dccab2 | Open Energy Information  

Open Energy Info (EERE)

b347101-f363-4d6c-ba46-1ad209dccab2 b347101-f363-4d6c-ba46-1ad209dccab2 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Columbia River Peoples Ut Dist Effective date: 2011/10/01 End date if known: Rate name: Outdoor Area Lighting 70w Sodium Vapor Sector: Lighting Description: Applicability To outdoor area lighting service on Customer property. Character of Service Lighting service from dusk to dawn daily, by means of PUD-owned luminaries mounted on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably possible after notification by the Customer and subject to the PUD's operating schedules and requirements.

375

Data:95957a4b-7e2b-41fe-a642-51703e1fc5fa | Open Energy Information  

Open Energy Info (EERE)

a4b-7e2b-41fe-a642-51703e1fc5fa a4b-7e2b-41fe-a642-51703e1fc5fa No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Columbia River Peoples Ut Dist Effective date: 2011/10/01 End date if known: Rate name: Outdoor Area Lighting 150w Sodium Vapor Area Light Style Sector: Lighting Description: Applicability To outdoor area lighting service on Customer property. Character of Service Lighting service from dusk to dawn daily, by means of PUD-owned luminaries mounted on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably possible after notification by the Customer and subject to the PUD's operating schedules and requirements.

376

Data:80545bfb-07c5-460a-8c4e-7e636f22ff83 | Open Energy Information  

Open Energy Info (EERE)

bfb-07c5-460a-8c4e-7e636f22ff83 bfb-07c5-460a-8c4e-7e636f22ff83 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Columbia River Peoples Ut Dist Effective date: 2011/10/01 End date if known: Rate name: Outdoor Area Lighting 100w Sodium Vapor Flood Light Style Sector: Lighting Description: Applicability To outdoor area lighting service on Customer property. Character of Service Lighting service from dusk to dawn daily, by means of PUD-owned luminaries mounted on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably possible after notification by the Customer and subject to the PUD's operating schedules and requirements.

377

Data:1a84a6ea-bfe8-403c-8f22-c85e8a48f3c3 | Open Energy Information  

Open Energy Info (EERE)

4a6ea-bfe8-403c-8f22-c85e8a48f3c3 4a6ea-bfe8-403c-8f22-c85e8a48f3c3 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Columbia River Peoples Ut Dist Effective date: 2011/10/01 End date if known: Rate name: Outdoor Area Lighting 200w Sodium Vapor Cobra Head Light Style Sector: Lighting Description: Applicability To outdoor area lighting service on Customer property. Character of Service Lighting service from dusk to dawn daily, by means of PUD-owned luminaries mounted on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably possible after notification by the Customer and subject to the PUD's operating schedules and requirements.

378

Data:8dfc12b7-8f92-41cf-ae09-58d9cb37a86b | Open Energy Information  

Open Energy Info (EERE)

2b7-8f92-41cf-ae09-58d9cb37a86b 2b7-8f92-41cf-ae09-58d9cb37a86b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Columbia River Peoples Ut Dist Effective date: 2011/10/01 End date if known: Rate name: Outdoor Area Lighting 100w Sodium Vapor Cobra Head Light Style Sector: Lighting Description: Applicability To outdoor area lighting service on Customer property. Character of Service Lighting service from dusk to dawn daily, by means of PUD-owned luminaries mounted on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably possible after notification by the Customer and subject to the PUD's operating schedules and requirements.

379

Data:Ea602702-2777-4ed7-a00e-c41af30caa64 | Open Energy Information  

Open Energy Info (EERE)

02-2777-4ed7-a00e-c41af30caa64 02-2777-4ed7-a00e-c41af30caa64 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Columbia River Peoples Ut Dist Effective date: 2011/10/01 End date if known: Rate name: Outdoor Area Lighting 175w Mercury Vapor Sector: Lighting Description: Applicability To outdoor area lighting service on Customer property. Character of Service Lighting service from dusk to dawn daily, by means of PUD-owned luminaries mounted on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably possible after notification by the Customer and subject to the PUD's operating schedules and requirements.

380

Data:5f4a0f12-fe92-4a3d-ab4c-d7fd2b5872ba | Open Energy Information  

Open Energy Info (EERE)

a0f12-fe92-4a3d-ab4c-d7fd2b5872ba a0f12-fe92-4a3d-ab4c-d7fd2b5872ba No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Columbia River Peoples Ut Dist Effective date: 2011/10/01 End date if known: Rate name: Outdoor Area Lighting 1000w Mercury Vapor Sector: Lighting Description: Applicability To outdoor area lighting service on Customer property. Character of Service Lighting service from dusk to dawn daily, by means of PUD-owned luminaries mounted on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably possible after notification by the Customer and subject to the PUD's operating schedules and requirements.

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Data:4d4a3bb2-d0d6-4d47-8afa-7003bd06f9b9 | Open Energy Information  

Open Energy Info (EERE)

d4a3bb2-d0d6-4d47-8afa-7003bd06f9b9 d4a3bb2-d0d6-4d47-8afa-7003bd06f9b9 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Columbia River Peoples Ut Dist Effective date: 2011/10/01 End date if known: Rate name: Outdoor Area Lighting 400w Sodium Vapor Flood Light Style Sector: Lighting Description: Applicability To outdoor area lighting service on Customer property. Character of Service Lighting service from dusk to dawn daily, by means of PUD-owned luminaries mounted on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably possible after notification by the Customer and subject to the PUD's operating schedules and requirements.

382

Data:1a8d6ca0-0e6e-484a-a960-41e34138aa76 | Open Energy Information  

Open Energy Info (EERE)

d6ca0-0e6e-484a-a960-41e34138aa76 d6ca0-0e6e-484a-a960-41e34138aa76 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Columbia River Peoples Ut Dist Effective date: 2011/10/01 End date if known: Rate name: Outdoor Area Lighting 400w Mercury Vapor Sector: Lighting Description: Applicability To outdoor area lighting service on Customer property. Character of Service Lighting service from dusk to dawn daily, by means of PUD-owned luminaries mounted on PUD-owned poles. Maintenance by the PUD includes lamp, photo cell and fixture replacement as needed. Individual lamps will be replaced on burnout as soon as reasonably possible after notification by the Customer and subject to the PUD's operating schedules and requirements.

383

Phosphors for LED lamps  

SciTech Connect (OSTI)

A phosphor, a phosphor blend including the phosphor, a phosphor prepared by a process, and a lighting apparatus including the phosphor blend are disclosed. The phosphor has the formula (Ca.sub.1-p-qCe.sub.pK.sub.q).sub.xSc.sub.y(Si.sub.1-rGa.sub.r).sub.zO.su- b.12+.delta. or derived from a process followed using disclosed amounts of reactants. In the formula, (0

Murphy, James Edward; Manepalli, Satya Kishore; Kumar, Prasanth Nammalwar

2013-08-13T23:59:59.000Z

384

The Carbon-Land Model Intercomparison Project (C-LAMP): A Model-Data Comparison System for Evaluation of Coupled Biosphere-Atmosphere Models  

SciTech Connect (OSTI)

The need to capture important climate feebacks in general circulation models (GCMs) has resulted in new efforts to include atmospheric chemistry and land and ocean biogeochemistry into the next generation of production climate models, now often referred to as Earth System Models (ESMs). While many terrestrial and ocean carbon models have been coupled to GCMs, recent work has shown that such models can yield a wide range of results, suggesting that a more rigorous set of offline and partially coupled experiments, along with detailed analyses of processes and comparisons with measurements, are warranted. The Carbon-Land Model Intercomparison Project (C-LAMP) provides a simulation protocol and model performance metrics based upon comparisons against best-available satellite- and ground-based measurements (Hoffman et al., 2007). C-LAMP provides feedback to the modeling community regarding model improvements and to the measurement community by suggesting new observational campaigns. C-LAMP Experiment 1 consists of a set of uncoupled simulations of terrestrial carbon models specifically designed to examine the ability of the models to reproduce surface carbon and energy fluxes at multiple sites and to exhibit the influence of climate variability, prescribed atmospheric carbon dioxide (CO{sub 2}), nitrogen (N) deposition, and land cover change on projections of terrestrial carbon fluxes during the 20th century. Experiment 2 consists of partially coupled simulations of the terrestrial carbon model with an active atmosphere model exchanging energy and moisture fluxes. In all experiments, atmospheric CO{sub 2} follows the prescribed historical trajectory from C{sup 4}MIP. In Experiment 2, the atmosphere model is forced with prescribed sea surface temperatures (SSTs) and corresponding sea ice concentrations from the Hadley Centre; prescribed CO{sub 2} is radiatively active; and land, fossil fuel, and ocean CO{sub 2} fluxes are advected by the model. Both sets of experiments have been performed using two different terrestrial biogeochemistry modules coupled to the Community Land Model version 3 (CLM3) in the Community Climate System Model version 3 (CCSM3): The CASA model of Fung, et al., and the carbon-nitrogen (CN) model of Thornton. Comparisons against Ameriflus site measurements, MODIS satellite observations, NOAA flask records, TRANSCOM inversions, and Free Air CO{sub 2} Enrichment (FACE) site measurements, and other datasets have been performed and are described in Randerson et al. (2009). The C-LAMP diagnostics package was used to validate improvements to CASA and CN for use in the next generation model, CLM4. It is hoped that this effort will serve as a prototype for an international carbon-cycle model benchmarking activity for models being used for the Inter-governmental Panel on Climate Change (IPCC) Fifth Assessment Report. More information about C-LAMP, the experimental protocol, performance metrics, output standards, and model-data comparisons from the CLM3-CASA and CLM3-CN models are available at http://www.climatemodeling.org/c-lamp.

Hoffman, Forrest M [ORNL; Randerson, Jim [University of California, Irvine; Thornton, Peter E [ORNL; Mahowald, Natalie [Cornell University; Bonan, Gordon [National Center for Atmospheric Research (NCAR); Running, Steven [University of Montana, Missoula; Fung, Inez [University of California, Berkeley

2009-01-01T23:59:59.000Z

385

Mercury Source Zone Identification using Soil Vapor Sampling and Analysis  

SciTech Connect (OSTI)

Development and demonstration of reliable measurement techniqes that can detect and help quantify the nature and extent of elemental mercury (Hg(0)) in the subsurface are needed to reduce certainties in the decision making process and increase the effectiveness of remedial actions. We conducted field tests at the Y-12 National Security Complex (NSC) in Oak Ridge, TN, to determine if sampling and analysis of Hg(0) vapors in the shallow subsurface (<0.3 m depth) can be used to as an indicator of the location and extent of Hg(0) releases in the subsurface. We constructed a rigid PVC pushprobe assembly, which was driven into the ground. Soil gas samples were collected through a sealed inner tube of the assembly and analyzed immediately in the field with a Lumex and/or Jerome Hg(0) analyzer. Time-series sampling showed that Hg vapor concentrations were fairly stable over time suggesting that the vapor phase Hg(0) was not being depleted and that sampling results were not dependent on the soil gas purge volume. Hg(0) vapor data collected at over 200 pushprobe locations at 3 different release sites correlated well to areas of known Hg(0) contamination. Vertical profiling of Hg(0) vapor concentrations conducted at 2 locations provided information on the vertical distribution of Hg(0) contamination in the subsurface. We concluded from our studies that soil gas sampling and analysis can be conducted rapidly and inexpensively at a large scale to help identify areas contaminated with Hg(0).

Watson, David B [ORNL] [ORNL; Miller, Carrie L [ORNL] [ORNL; Lester, Brian P [ORNL] [ORNL; Lowe, Kenneth Alan [ORNL] [ORNL; Southworth, George R [ORNL] [ORNL; Bogle, Mary Anna [ORNL] [ORNL; Liang, Liyuan [ORNL] [ORNL; Pierce, Eric M [ORNL] [ORNL

2014-01-01T23:59:59.000Z

386

Vapor etching of nuclear tracks in dielectric materials  

DOE Patents [OSTI]

A process involving vapor etching of nuclear tracks in dielectric materials for creating high aspect ratio (i.e., length much greater than diameter), isolated cylindrical holes in dielectric materials that have been exposed to high-energy atomic particles. The process includes cleaning the surface of the tracked material and exposing the cleaned surface to a vapor of a suitable etchant. Independent control of the temperatures of the vapor and the tracked materials provide the means to vary separately the etch rates for the latent track region and the non-tracked material. As a rule, the tracked regions etch at a greater rate than the non-tracked regions. In addition, the vapor-etched holes can be enlarged and smoothed by subsequent dipping in a liquid etchant. The 20-1000 nm diameter holes resulting from the vapor etching process can be useful as molds for electroplating nanometer-sized filaments, etching gate cavities for deposition of nano-cones, developing high-aspect ratio holes in trackable resists, and as filters for a variety of molecular-sized particles in virtually any liquid or gas by selecting the dielectric material that is compatible with the liquid or gas of interest.

Musket, Ronald G. (Danville, CA); Porter, John D. (Berkeley, CA); Yoshiyama, James M. (Fremont, CA); Contolini, Robert J. (Lake Oswego, OR)

2000-01-01T23:59:59.000Z

387

2014-12-05 Issuance: Energy Conservation Standard for General Service Lamps; Notice of Public Meeting and Availability of the Preliminary Technical Support Document  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of public meeting and availability of the preliminary technical support document regarding energy conservation standards for general service lamps, as issued by the Deputy Assistant Secretary for Energy Efficiency on December 5, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

388

Tungsten and tungsten alloy powder metallurgy: Powder production and applications excluding lamps. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search  

SciTech Connect (OSTI)

The bibliography contains citations of selected patents concerning the preparation of metallic and ceramic powders of tungsten and tungsten alloys, including applications of these materials. The hydrogen reduction of tungsten compounds together with alloying element compounds produce forms with characteristics of high density, hardness, wear resistance, high melting points, and abrasiveness. Topics include production of cathodes, heaters, filament wires, electrical contacts, acoustic absorbers, high-density sheets and coatings, hard penetrators, and tungsten carbide and metallized ceramics. Tungsten halogen lamps are examined in a separate bibliography.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

NONE

1997-01-01T23:59:59.000Z

389

Tungsten and tungsten alloy powder metallurgy: Powder production and applications excluding lamps. (Latest citations from the US Patent database). Published Search  

SciTech Connect (OSTI)

The bibliography contains citations of selected patents concerning the preparation of metallic and ceramic powders of tungsten and tungsten alloys, including applications of these materials. The hydrogen reduction of tungsten compounds together with alloying element compounds produce forms with characteristics of high density, hardness, wear resistance, high melting points, and abrasiveness. Topics include production of cathodes, heaters, filament wires, electrical contacts, acoustic absorbers, high-density sheets and coatings, hard penetrators, and tungsten carbide and metallized ceramics. Tungsten halogen lamps are examined in a separate bibliography. (Contains a minimum of 97 citations and includes a subject term index and title list.)

Not Available

1993-05-01T23:59:59.000Z

390

Tungsten and tungsten alloy powder metallurgy: Powder production and applications excluding lamps. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search  

SciTech Connect (OSTI)

The bibliography contains citations of selected patents concerning the preparation of metallic and ceramic powders of tungsten and tungsten alloys, including applications of these materials. The hydrogen reduction of tungsten compounds together with alloying element compounds produce forms with characteristics of high density, hardness, wear resistance, high melting points, and abrasiveness. Topics include production of cathodes, heaters, filament wires, electrical contacts, acoustic absorbers, high-density sheets and coatings, hard penetrators, and tungsten carbide and metallized ceramics. Tungsten halogen lamps are examined in a separate bibliography.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

NONE

1995-12-01T23:59:59.000Z

391

Tungsten and tungsten alloy powder metallurgy: Powder production and applications excluding lamps. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search  

SciTech Connect (OSTI)

The bibliography contains citations of selected patents concerning the preparation of metallic and ceramic powders of tungsten and tungsten alloys, including applications of these materials. The hydrogen reduction of tungsten compounds together with alloying element compounds produce forms with characteristics of high density, hardness, wear resistance, high melting points, and abrasiveness. Topics include production of cathodes, heaters, filament wires, electrical contacts, acoustic absorbers, high-density sheets and coatings, hard penetrators, and tungsten carbide and metallized ceramics. Tungsten halogen lamps are examined in a separate bibliography. (Contains a minimum of 115 citations and includes a subject term index and title list.)

NONE

1995-02-01T23:59:59.000Z

392

Validation of TES Temperature and Water Vapor Retrievals with ARM  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Validation of TES Temperature and Water Vapor Retrievals with ARM Validation of TES Temperature and Water Vapor Retrievals with ARM Observations Cady-Pereira, Karen Atmospheric and Environmental Research, Inc. Shephard, Mark Atmospheric and Environmental Research, Inc. Clough, Shepard Atmospheric and Environmental Research Mlawer, Eli Atmospheric & Environmental Research, Inc. Turner, David University of Wisconsin-Madison Category: Atmospheric State and Surface The primary objective of the TES (Tropospheric Emission Spectrometer) instrument on the Aura spacecraft is the retrieval of trace gases, especially water vapor and ozone. The TES retrievals extremely useful for global monitoring of the atmospheric state, but they must be validated. The ARM sites are well instrumented and provide continuous measurements, which

393

VAPORIZATION OF TUNGSTEN-METAL IN STEAM AT HIGH TEMPERATURES.  

SciTech Connect (OSTI)

The vaporization of tungsten from the APT spallation target dominates the radiological source term for unmitigated target overheating accidents. Chemical reactions of tungsten with steam which persist to tungsten temperatures as low as 800 C result in the formation of a hydrated tungsten-oxide which has a high vapor pressure and is readily convected in a flowing atmosphere. This low-temperature vaporization reaction essentially removes the oxide film that forms on the tungsten-metal surface as soon as it forms, leaving behind a fresh metallic surface for continued oxidation and vaporization. Experiments were conducted to measure the oxidative vaporization rates of tungsten in steam as part of the effort to quantify the MT radiological source term for severe target accidents. Tests were conducted with tungsten rods (1/8 inch diameter, six inches long) heated to temperatures from approximately 700 C to 1350 C in flowing steam which was superheated to 140 C. A total of 19 experiments was conducted. Fifteen tests were conducted by RF induction heating of single tungsten rods held vertical in a quartz glass retort. Four tests were conducted in a vertically-mounted tube furnace for the low temperature range of the test series. The aerosol which was generated and transported downstream from the tungsten rods was collected by passing the discharged steam through a condenser. This procedure insured total collection of the steam along with the aerosol from the vaporization of the rods. The results of these experiments revealed a threshold temperature for tungsten vaporization in steam. For the two tests at the lowest temperatures which were tested, approximately 700 C, the tungsten rods were observed to oxidize without vaporization. The remainder of the tests was conducted over the temperature range of 800 C to 1350 C. In these tests, the rods were found to have lost weight due to vaporization of the tungsten and the missing weight was collected in the downstream condensate system. The aerosol formed a fine white smoke of tungsten-oxide which was visible to the eye as it condensed in the laminar boundary layer of steam which flowed along the surface of the rod. The aerosol continued to flow as a smoke tube downstream of the rod, flowing coaxially along the centerline axis of the quartz glass tube and depositing by impaction along the outside of a bend and at sudden area contractions in the piping. The vaporization rate data from the 17 experiments which exceeded the vaporization threshold temperature are shown in Figure 5 in the form of vaporization rates (g/cm{sup 2} s) vs. inverse temperature (K{sup {minus}1}). Two correlations to the present data are presented and compared to a published correlation by Kilpatrick and Lott. The differences are discussed.

GREENE,G.A.; FINFROCK,C.C.

2000-10-01T23:59:59.000Z

394

Phase effects for electrons in liquid water and water vapor  

SciTech Connect (OSTI)

The objective of these studies is to compare transport, energy loss, and other phenomena for electrons in water in the liquid and vapor phases. Understanding the differences and similarities is an interesting physics problem in its own right. It is also important for applying the relatively large body of experimental data available for the vapor to the liquid, which is of greater relevance in radiobiology. This paper presents a summary of results from a series of collaborative studies carried out by the authors at Oak Ridge National Laboratory (ORNL) and the Gesellschaft fuer Strahlen- und Umweltforschung (GSF). 14 figs.

Turner, J.E.; Paretzke, H.G.; Wright, H.A.; Hamm, R.N.; Ritchie, R.H.

1988-01-01T23:59:59.000Z

395

Growth of manganese filled carbon nanofibers in the vapor phase  

Science Journals Connector (OSTI)

We report the vapor phase growth of partially filled graphitic fibers, 20-30 nm in diameter and up to a micron in length, during a manganese catalyzed carbon electric arc discharge. The fiber morphology resembles that of catalytic chemical vapor deposited carbon filaments but the inside hollow contains intermittent precipitates and continuous filling of Mn that at times occupy >50% of fiber lengths. Transmission electron microscopy and electron energy loss line spectra show that the fillings form as solid cores and may correspond to pure metal.

P. M. Ajayan; C. Colliex; J. M. Lambert; P. Bernier; L. Barbedette; M. Tence; O. Stephan

1994-03-14T23:59:59.000Z

396

The development of a passive dosimeter for airborne aniline vapors  

E-Print Network [OSTI]

passive sampl1ng dosimeter was designed to measure concen- trat1ons of aniline vapor in air. Diffus1on tubes of 1. 5, 3. 0 and 4. 5 cm lengths were tested under controlled conditions of relative humid1ty, air temperature and vapor concentrations. A... of Measured vs Calculated Concentrations APPENDIX D-Student-t Test on Slopes of Measured vs Calculated Data . APPENDIX E-Statistical Analysis of Four Hour Time- Weighted Average Study on 3. 0 cm Dosimeter VITA ~pa e 42 45 48 59 62 63 65 70 73...

Campbell, James Evan

1977-01-01T23:59:59.000Z

397

Solid–Liquid–Vapor Equilibrium Models for Cryogenic Biogas Upgrading  

Science Journals Connector (OSTI)

In cryogenic upgrading processes involving dry ice formation, accurate predictions of solid–liquid, solid–vapor, and solid–liquid–vapor equilibria are fundamental for a correct design of the heat exchanger surface in order to achieve the desired biomethane purity. ... Moreover, the liquefied biogas production process, particularly interesting for cryogenic upgrading processes due to the low temperature of the obtained biomethane, requires an accurate knowledge of carbon dioxide solubility in liquid methane to avoid solid deposition. ... For some applications demanding a high energy content gas, namely vehicle fuels and injection in the natural gas grid, the biogas has to be upgraded into biomethane. ...

Mauro Riva; Marco Campestrini; Joseph Toubassy; Denis Clodic; Paolo Stringari

2014-10-13T23:59:59.000Z

398

UNCORRECTEDPROOF 2 Vaporization, fusion and sublimation enthalpies of the  

E-Print Network [OSTI]

UNCORRECTEDPROOF 2 Vaporization, fusion and sublimation enthalpies of the 3 dicarboxylic acids from of Chemistry and Biochemistry, University of Missouri-St. Louis, 8001 Natural Bridge, St. Louis, MO 63121, USA observed previously in the sublimation enthalpies of these compounds. The results are dis- 16 cussed

Chickos, James S.

399

Vapor-side corrosion in thermal desalination plants  

SciTech Connect (OSTI)

This article reports the results of vapor-size corrosion monitoring studies carried out in multistage flash (MSF) desal unit No. 100 of Al-Khafji power and Desalination Plant in Saudi Arabia. Corrosion behavior of 70/30 Cu-Ni alloy, carbon steel (CS), and type 316L stainless steel (SS) was studied in vents and in the vapor size of distillers for 2,000, 4,000, and 9,000 h. Analyses of the experimental data indicated that in addition to O{sub 2}, S-containing compounds evolved during flashing of seawater reacted more with Cu-Ni alloy than with CS and type 316L SS. Explanations for comparatively higher corrosion of alloys exposed to the vapors of the first three (1 to 3) and middle (11 to 13) stages of the MSF plant are given with experimental results. Type 316L SS was found to be the alloy most resistant to vapor-side corrosion in all stages of distillers.

Asrar, N.; Malik, A.U.; Ahmed, S. [Saline Water Conversion Corp. (Saudi Arabia); Al-Khalidi, M.; Al-Moaili, K. [Al-Khafji Desalination Plant (Saudi Arabia)

1999-04-01T23:59:59.000Z

400

Fatigue Resistance of Asphalt Mixtures Affected by Water Vapor Movement  

E-Print Network [OSTI]

This dissertation has two key objectives: the first objective is to develop a method of predicting and quantifying the amount of water that can enter into a pavement system by vapor transport; the second objective is to identify to which extent...

Tong, Yunwei

2013-11-08T23:59:59.000Z

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

The chemical vapor deposition of zirconium carbide onto ceramic substrates  

SciTech Connect (OSTI)

Zirconium carbide is an attractive ceramic material due to its unique properties such as high melting point, good thermal conductivity, and chemical resistance. The controlled preparation of zirconium carbide films of superstoichiometric, stoichiometric, and substoichiometric compositions has been achieved utilizing zirconium tetrachloride and methane precursor gases in an atmospheric pressure high temperature chemical vapor deposition system.

Glass, John A, Jr.; Palmisiano, Nick, Jr.; Welsh, R. Edward

1999-07-01T23:59:59.000Z

402

A transient model for a cesium vapor thermionic converter. [Cs  

SciTech Connect (OSTI)

This paper presents an analytical model for simulating the transient and steady-state operation of cesium vapor thermionic converters. A parametric analysis is performed to assess the transient response of the converter to changes in fission power and width of interelectrode gap. The model optimizes the converter performance for maximum electric power to the load.(AIP)

El-Genk, M.S.; Murray, C.S.; Chaudhuri, S. (Institute for Space Nuclear Power Studies, Department of Chemical and Nuclear Engineering, The University of New Mexico, Albuquerque, New Mexico (USA))

1991-01-10T23:59:59.000Z

403

Experimental Study of Water Vapor Adsorption on Geothermal  

E-Print Network [OSTI]

Geothermal Program under Department of Energy Grant No. DE-FG07-90IDI2934,and by the Department of PetroleumSGP-TR-148 Experimental Study of Water Vapor Adsorption on Geothermal Reservoir Rocks Shubo Shang Engineering, Stanford University Stanford Geothermal Program Interdisciplinary Research in Engineering

Stanford University

404

CVD CNT CNT (Vapor-grown carbon fiber, VGCF)  

E-Print Network [OSTI]

CNT CNT CVD CNT CNT (Vapor-grown carbon fiber, VGCF) 10001300 CNT CVD Smalley CO 24 CCVD 1 #12; 27 mm 3% 200 sccm 800 10 10 Torr 300 sccm Ethanol tank Hot bath boat Ar/H2 Ar or Ethanol tank Hot bath Ethanol tank Hot bath Pressure gauge Maindraintube Subdraintube

Maruyama, Shigeo

405

Method for removing metal vapor from gas streams  

DOE Patents [OSTI]

A process for cleaning an inert gas contaminated with a metallic vapor, such as cadmium, involves withdrawing gas containing the metallic contaminant from a gas atmosphere of high purity argon; passing the gas containing the metallic contaminant to a mass transfer unit having a plurality of hot gas channels separated by a plurality of coolant gas channels; cooling the contaminated gas as it flows upward through the mass transfer unit to cause contaminated gas vapor to condense on the gas channel walls; regenerating the gas channels of the mass transfer unit; and, returning the cleaned gas to the gas atmosphere of high purity argon. The condensing of the contaminant-containing vapor occurs while suppressing contaminant particulate formation, and is promoted by providing a sufficient amount of surface area in the mass transfer unit to cause the vapor to condense and relieve supersaturation buildup such that contaminant particulates are not formed. Condensation of the contaminant is prevented on supply and return lines in which the contaminant containing gas is withdrawn and returned from and to the electrorefiner and mass transfer unit by heating and insulating the supply and return lines.

Ahluwalia, R. K. (6440 Hillcrest Dr., Burr Ridge, IL 60521); Im, K. H. (925 Lehigh Cir., Naperville, IL 60565)

1996-01-01T23:59:59.000Z

406

Sorption and Diffusion of Organic Vapors in Two Fluoroelastomers  

E-Print Network [OSTI]

Sorption and Diffusion of Organic Vapors in Two Fluoroelastomers PING WANG,* NATHANIEL S. SCHNEIDER of II in polar liquids: over 100% (wt/wt) in two ketones and a phosphate ester. Sorption isotherms deter determined from sorption kinetics, corrected for nonisothermal effects, and converted to solvent self

Wang, Ping

407

High-resolution terahertz atmospheric water vapor continuum measurements  

E-Print Network [OSTI]

High-resolution terahertz atmospheric water vapor continuum measurements David M. Slocum,* Thomas M such as pollution monitoring and the detection of energetic chemicals using remote sensing over long path lengths through the atmosphere. Although there has been much attention to atmospheric effects over narrow

Massachusetts at Lowell, University of

408

Data:C6d91e2c-d33f-4ba3-9628-a47acfd4e27d | Open Energy Information  

Open Energy Info (EERE)

d91e2c-d33f-4ba3-9628-a47acfd4e27d d91e2c-d33f-4ba3-9628-a47acfd4e27d No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 250W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',WoodPole(2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

409

Data:D6b9eb6e-d770-4a1b-ab03-1c9c25176bcc | Open Energy Information  

Open Energy Info (EERE)

eb6e-d770-4a1b-ab03-1c9c25176bcc eb6e-d770-4a1b-ab03-1c9c25176bcc No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 250W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Flood',WoodPole(2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

410

Data:Cc8b221c-4d64-4d1f-94d1-1076e23a599b | Open Energy Information  

Open Energy Info (EERE)

b221c-4d64-4d1f-94d1-1076e23a599b b221c-4d64-4d1f-94d1-1076e23a599b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 150W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Ornamental',FiberglassPole(3)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

411

Data:C319b5ab-1712-47c4-8e11-0ec0b1a36ffe | Open Energy Information  

Open Energy Info (EERE)

b5ab-1712-47c4-8e11-0ec0b1a36ffe b5ab-1712-47c4-8e11-0ec0b1a36ffe No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 400W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',FiberglassPole(3)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

412

Data:7a687952-a9c0-4f0f-a05b-4f9fb28b91ea | Open Energy Information  

Open Energy Info (EERE)

952-a9c0-4f0f-a05b-4f9fb28b91ea 952-a9c0-4f0f-a05b-4f9fb28b91ea No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Three Notch Elec Member Corp Effective date: 2012/03/01 End date if known: Rate name: 400W Underground Wiring (Non Mercury vapor fixtures) - (Type - 'HPS-Cobra',WoodPole(2)) Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Cooperative's specifications. Service will be rendered only at locations that, solely in the opinion of the Cooperative, are readily accessible for installation and maintenance.

413

Method and apparatus to measure vapor pressure in a flow system  

DOE Patents [OSTI]

The present invention is directed to a method for determining, by a condensation method, the vapor pressure of a material with a known vapor pressure versus temperature characteristic, in a flow system particularly in a mercury isotope enrichment process.

Grossman, Mark W. (Belmont, MA); Biblarz, Oscar (Swampscott, MA)

1991-01-01T23:59:59.000Z

414

Tropical Water Vapor and Cloud Feedbacks in Climate Models: A Further Assessment Using Coupled Simulations  

Science Journals Connector (OSTI)

By comparing the response of clouds and water vapor to ENSO forcing in nature with that in Atmospheric Model Intercomparison Project (AMIP) simulations by some leading climate models, an earlier evaluation of tropical cloud and water vapor ...

De-Zheng Sun; Yongqiang Yu; Tao Zhang

2009-03-01T23:59:59.000Z

415

Metalorganic chemical vapor deposition of carbon-free ZnO using...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Metalorganic chemical vapor deposition of carbon-free ZnO using the bis(2,2,6,6-tetramethyl-3,5-heptanedionato)zinc precursor. Metalorganic chemical vapor deposition of carbon-free...

416

Economic and Technical Tradeoffs Between Open and Closed Cycle Vapor Compression Evaporators  

E-Print Network [OSTI]

and solute. Evaporation tends to be a very energy intensive process. Approximately 1000 BTUs of energy are required to vaporize one pound of water. Many techniques have been developed to reuse energy Within an evaporation system so as to vaporize... Recompression A schematic of an open cycle vapor recompression evaporator is shown in Figure 2. This method uses the vapor in an open cycle for both heating and cooling. Rather than being condensed after the last effect, steam is compressed to a slightly...

Timm, M. L.

417

Quantitative Analysis of Ternary Vapor Mixtures Using a Microcantilever-Based Electronic Nose  

SciTech Connect (OSTI)

The authors report the identification and quantification of the components of a ternary vapor mixture using a microcantilever-based electronic nose. An artificial neural network was used for pattern recognition. Dimethyl methyl phosphonate vapor in ppb concentrations and water and ethanol vapors in ppm concentrations were quantitatively identified either individually or in binary and ternary mixtures at varying concentrations.

Pinnaduwage, Lal A [ORNL; Zhao, Weichang [ORNL; Gehl, Anthony C [ORNL; Allman, Steve L [ORNL

2007-01-01T23:59:59.000Z

418

Sample Vapor Introduction Techniques for Use with Cryofocusing GC Inlet Systems  

Science Journals Connector (OSTI)

......the vapor generator was operated at atmospheric pressure for...condensed water. Other studies...Because the water vapor was...tail of the water peak. Thus...obtained from an atmospheric pressure source...the vapor generator over a 1......

Christine L. Rankin; Richard D. Sacks

1994-01-01T23:59:59.000Z

419

Measurements of atmospheric water vapor above Mauna Kea using an infrared radiometer  

E-Print Network [OSTI]

Measurements of atmospheric water vapor above Mauna Kea using an infrared radiometer David A in atmospheric water vapor that distort the phase coherence of incoming celestial signals. The signal received water vapor, this paper presents results obtained with a second generation IRMA operating at the James

Naylor, David A.

420

Thorium, uranium and rare earth elements content in lanthanide concentrate (LC) and water leach purification (WLP) residue of Lynas advanced materials plant (LAMP)  

SciTech Connect (OSTI)

Lynas Advanced Materials Plant (LAMP) has been licensed to produce the rare earths elements since early 2013 in Malaysia. LAMP processes lanthanide concentrate (LC) to extract rare earth elements and subsequently produce large volumes of water leach purification (WLP) residue containing naturally occurring radioactive material (NORM). This residue has been rising up the environmental issue because it was suspected to accumulate thorium with significant activity concentration and has been classified as radioactive residue. The aim of this study is to determine Th-232, U-238 and rare earth elements in lanthanide concentrate (LC) and water leach purification (WLP) residue collected from LAMP and to evaluate the potential radiological impacts of the WLP residue on the environment. Instrumental Neutron Activation Analysis and ?-spectrometry were used for determination of Th, U and rare earth elements concentrations. The results of this study found that the concentration of Th in LC was 1289.7 ± 129 ppm (5274.9 ± 527.6Bq/kg) whereas the Th and U concentrations in WLP were determined to be 1952.9±17.6 ppm (7987.4 ± 71.9 Bq/kg) and 17.2 ± 2.4 ppm respectively. The concentrations of Th and U in LC and WLP samples determined by ?- spectrometry were 1156 ppm (4728 ± 22 Bq/kg) and 18.8 ppm and 1763.2 ppm (7211.4 Bq/kg) and 29.97 ppm respectively. This study showed that thorium concentrations were higher in WLP compare to LC. This study also indicate that WLP residue has high radioactivity of {sup 232}Th compared to Malaysian soil natural background (63 - 110 Bq/kg) and come under preview of Act 304 and regulations. In LC, the Ce and Nd concentrations determined by INAA were 13.2 ± 0.6% and 4.7 ± 0.1% respectively whereas the concentrations of La, Ce, Nd and Sm in WLP were 0.36 ± 0.04%, 1.6%, 0.22% and 0.06% respectively. This result showed that some amount of rare earth had not been extracted and remained in the WLP and may be considered to be reextracted.

AL-Areqi, Wadeeah M., E-mail: walareqi@yahoo.com; Majid, Amran Ab., E-mail: walareqi@yahoo.com; Sarmani, Sukiman, E-mail: walareqi@yahoo.com [Nuclear Science Programme, School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi (Malaysia)

2014-02-12T23:59:59.000Z

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Method for the generation of variable density metal vapors which bypasses the liquidus phase  

DOE Patents [OSTI]

The present invention provides a method for producing a metal vapor that includes the steps of combining a metal and graphite in a vessel to form a mixture; heating the mixture to a first temperature in an argon gas atmosphere to form a metal carbide; maintaining the first temperature for a period of time; heating the metal carbide to a second temperature to form a metal vapor; withdrawing the metal vapor and the argon gas from the vessel; and separating the metal vapor from the argon gas. Metal vapors made using this method can be used to produce uniform powders of the metal oxide that have narrow size distribution and high purity.

Kunnmann, Walter (Stony Brook, NY); Larese, John Z. (Rocky Point, NY)

2001-01-01T23:59:59.000Z

422

Mercury Vapor At Mokapu Penninsula Area (Thomas, 1986) | Open Energy  

Open Energy Info (EERE)

Mokapu Penninsula Area (Thomas, 1986) Mokapu Penninsula Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Mokapu Penninsula Area (Thomas, 1986) Exploration Activity Details Location Mokapu Penninsula Area Exploration Technique Mercury Vapor Activity Date Usefulness not useful DOE-funding Unknown Notes The high degree of cultural activity (e.g. residential areas, streets, jet runways, etc.) on Mokapu both limited the extent of the soil geochemical surveys performed and rendered their interpretation much more difficult. Soil mercury concentrations and radon emanometry data on the peninsula showed a few localized high values (Figs 13, 14), but no consistent correlation between the anomalous zones and geologic features could be

423

Detonation wave driven by condensation of supersaturated carbon vapor  

Science Journals Connector (OSTI)

An experimental observation of a detonation wave driven by the energy of condensation of supersaturated carbon vapor is reported. The carbon vapor was formed by the thermal decay of unstable carbon suboxide C3O2 behind shock waves in mixtures containing 10–30% C3O2 in Ar. In the mixture 10% C3O2+Ar the insufficient heat release resulted in a regime of overdriven detonation. In the mixture 20% C3O2+Ar measured values of the pressure and wave velocity coincident with calculated Chapman-Jouguet parameters were attained. In the richest mixture 30% C3O2+Ar an excess heat release caused the slowing down of the condensation rate and the regime of underdriven detonation was observed.

A. Emelianov; A. Eremin; V. Fortov; H. Jander; A. Makeich; H. Gg. Wagner

2009-03-10T23:59:59.000Z

424

Fabrication of solid oxide fuel cell by electrochemical vapor deposition  

DOE Patents [OSTI]

In a high temperature solid oxide fuel cell (SOFC), the deposition of an impervious high density thin layer of electrically conductive interconnector material, such as magnesium doped lanthanum chromite, and of an electrolyte material, such as yttria stabilized zirconia, onto a porous support/air electrode substrate surface is carried out at high temperatures (approximately 1100.degree.-1300.degree. C.) by a process of electrochemical vapor deposition. In this process, the mixed chlorides of the specific metals involved react in the gaseous state with water vapor resulting in the deposit of an impervious thin oxide layer on the support tube/air electrode substrate of between 20-50 microns in thickness. An internal heater, such as a heat pipe, is placed within the support tube/air electrode substrate and induces a uniform temperature profile therein so as to afford precise and uniform oxide deposition kinetics in an arrangement which is particularly adapted for large scale, commercial fabrication of SOFCs.

Brian, Riley (Willimantic, CT); Szreders, Bernard E. (Oakdale, CT)

1989-01-01T23:59:59.000Z

425

Fabrication of solid oxide fuel cell by electrochemical vapor deposition  

DOE Patents [OSTI]

In a high temperature solid oxide fuel cell (SOFC), the deposition of an impervious high density thin layer of electrically conductive interconnector material, such as magnesium doped lanthanum chromite, and of an electrolyte material, such as yttria stabilized zirconia, onto a porous support/air electrode substrate surface is carried out at high temperatures (/approximately/1100/degree/ /minus/ 1300/degree/C) by a process of electrochemical vapor deposition. In this process, the mixed chlorides of the specific metals involved react in the gaseous state with water vapor resulting in the deposit of an impervious thin oxide layer on the support tube/air electrode substrate of between 20--50 microns in thickness. An internal heater, such as a heat pipe, is placed within the support tube/air electrode substrate and induces a uniform temperature profile therein so as to afford precise and uniform oxide deposition kinetics in an arrangement which is particularly adapted for large scale, commercial fabrication of SOFCs.

Riley, B.; Szreders, B.E.

1988-04-26T23:59:59.000Z

426

Data:A21c12f2-72eb-46ad-b220-631458e29409 | Open Energy Information  

Open Energy Info (EERE)

2f2-72eb-46ad-b220-631458e29409 2f2-72eb-46ad-b220-631458e29409 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Springfield, Oregon (Utility Company) Effective date: 2012/04/01 End date if known: Rate name: Private Lighting 175 W MV L-3 Sector: Lighting Description: New Lighting systems shall be overhead construction consisting of wood poles, aerial circuits, and conventional street lighting luminaries with mast arms not longer than ten feet, or floodlighting luminaries with no mast arms. The installed luminaries shall use low-pressure sodium lamps. All equipment used to provide service under this schedule will be furnished, owned, operated and maintained by the Springfield Utility Board.

427

Data:821153d6-7906-4372-af02-5219546dcf65 | Open Energy Information  

Open Energy Info (EERE)

d6-7906-4372-af02-5219546dcf65 d6-7906-4372-af02-5219546dcf65 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Springfield, Oregon (Utility Company) Effective date: 2013/05/01 End date if known: Rate name: Private Lighting 200 W HPS L-3 Sector: Lighting Description: New Lighting systems shall be overhead construction consisting of wood poles, aerial circuits, and conventional street lighting luminaries with mast arms not longer than ten feet, or floodlighting luminaries with no mast arms. The installed luminaries shall use low-pressure sodium lamps. All equipment used to provide service under this schedule will be furnished, owned, operated and maintained by the Springfield Utility Board.

428

Data:868d2639-dc07-45f0-ab24-163991351a24 | Open Energy Information  

Open Energy Info (EERE)

639-dc07-45f0-ab24-163991351a24 639-dc07-45f0-ab24-163991351a24 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Springfield, Oregon (Utility Company) Effective date: 2013/05/01 End date if known: Rate name: Private Lighting 135 W LPS L-3 Sector: Lighting Description: New Lighting systems shall be overhead construction consisting of wood poles, aerial circuits, and conventional street lighting luminaries with mast arms not longer than ten feet, or floodlighting luminaries with no mast arms. The installed luminaries shall use low-pressure sodium lamps. All equipment used to provide service under this schedule will be furnished, owned, operated and maintained by the Springfield Utility Board.

429

Data:88daad39-99db-4255-8509-8288aa8351cf | Open Energy Information  

Open Energy Info (EERE)

daad39-99db-4255-8509-8288aa8351cf daad39-99db-4255-8509-8288aa8351cf No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Springfield, Oregon (Utility Company) Effective date: 2013/05/01 End date if known: Rate name: Private Lighting 400 W MH L-3 Sector: Lighting Description: New Lighting systems shall be overhead construction consisting of wood poles, aerial circuits, and conventional street lighting luminaries with mast arms not longer than ten feet, or floodlighting luminaries with no mast arms. The installed luminaries shall use low-pressure sodium lamps. All equipment used to provide service under this schedule will be furnished, owned, operated and maintained by the Springfield Utility Board.

430

Data:Fdc92dec-4887-4725-bcd1-6ed36c5dbebb | Open Energy Information  

Open Energy Info (EERE)

Fdc92dec-4887-4725-bcd1-6ed36c5dbebb Fdc92dec-4887-4725-bcd1-6ed36c5dbebb No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Springfield, Oregon (Utility Company) Effective date: 2013/05/01 End date if known: Rate name: Private Lighting 250 W HPS L-3 Sector: Lighting Description: New Lighting systems shall be overhead construction consisting of wood poles, aerial circuits, and conventional street lighting luminaries with mast arms not longer than ten feet, or floodlighting luminaries with no mast arms. The installed luminaries shall use low-pressure sodium lamps. All equipment used to provide service under this schedule will be furnished, owned, operated and maintained by the Springfield Utility Board.

431

Data:14ca05f6-f402-47f7-aa65-f7476d864844 | Open Energy Information  

Open Energy Info (EERE)

5f6-f402-47f7-aa65-f7476d864844 5f6-f402-47f7-aa65-f7476d864844 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Springfield, Oregon (Utility Company) Effective date: 2013/05/01 End date if known: Rate name: Private Lighting 250 W MH L-3 Sector: Lighting Description: New Lighting systems shall be overhead construction consisting of wood poles, aerial circuits, and conventional street lighting luminaries with mast arms not longer than ten feet, or floodlighting luminaries with no mast arms. The installed luminaries shall use low-pressure sodium lamps. All equipment used to provide service under this schedule will be furnished, owned, operated and maintained by the Springfield Utility Board.

432

Specific Mass Estimates for A Vapor Core Reactor With MHD  

SciTech Connect (OSTI)

This study investigated the development of a system concept for space power generation and nuclear electric propulsion based on a vapor core reactor (VCR) with magnetohydrodynamic (MHD) power conversion system, coupled to a magnetoplasma-dynamic (MPD) thruster. The VCR is a liquid-vapor core reactor concept operating with metallic uranium or uranium tetrafluoride (UF{sub 4}) vapor as the fissioning fuel and alkali metals or their fluorides as working fluid in a closed Rankine cycle with MHD energy conversion. Gaseous and liquid-vapor core reactors can potentially provide the highest reactor and cycle temperature among all existing or proposed fission reactor designs. This unique feature makes this reactor concept a very natural and attractive candidate for very high power (10 to 1000 MWe) and low specific mass (0.4 to 5 kg/kWe) nuclear electric propulsion (NEP) applications since the MHD output could be coupled with minimal power conditioning to MPD thrusters or other types of thruster for producing thrust at very high specific impulse (I{sub sp} 1500 to 10,000 s). The exceptional specific mass performance of an optimized VCRMHD- NEP system could lead to a dramatic reduction in the cost and duration of manned or robotic interplanetary as well as interstellar missions. The VCR-MHD-NEP system could enable very efficient Mars cargo transfers or short (<8 month) Mars round trips with less initial mass in low Earth orbit (IMLEO). The system could also enable highly efficient lunar cargo transfer and rapid missions to other destinations throughout the solar system. (authors)

Knight, Travis; Smith, Blair; Anghaie, Samim [Innovative Nuclear Space Power and Propulsion Institute (INSPI), PO Box 116502, University of Florida, Gainesville, FL 32611-6502 (United States)

2002-07-01T23:59:59.000Z

433

Heat Recovery in Distillation by Mechanical Vapor Recompression  

E-Print Network [OSTI]

be classified generally into two types,.aerodynamic and positive displacement (Figure 5). Among the various types of compressors, centrifugal, reciprocating, lobe and screw have been used for vapor recompression. I AXIAL AERODYNAMIC I I CENTRIFUGAL I... speeds of centri fugal compressors make them highly susceptible to erosion from entrained liquid droplets. This ero sion can reduce the efficiency and cause dynamic instability from rotor imbalance and mechanical failure. Next, it is important...

Becker, F. E.; Zakak, A. I.

434

High average power magnetic modulator for metal vapor lasers  

DOE Patents [OSTI]

A three-stage magnetic modulator utilizing magnetic pulse compression designed to provide a 60 kV pulse to a copper vapor laser at a 4.5 kHz repetition rate is disclosed. This modulator operates at 34 kW input power. The circuit includes a step up auto transformer and utilizes a rod and plate stack construction technique to achieve a high packing factor.

Ball, Don G. (Livermore, CA); Birx, Daniel L. (Oakley, CA); Cook, Edward G. (Livermore, CA); Miller, John L. (Livermore, CA)

1994-01-01T23:59:59.000Z

435

Methanol vaporization and injection system for internal combustion engine  

SciTech Connect (OSTI)

An engine equipped with an alcohol vaporization injection system operates as a four stroke cycle diesel engine that transfers the heat of exiting exhaust gases and cylinder head walls to the fuel. The engine runs on alcohol. The alcohol becomes vaporized and its pressure is high enough so that when a valve is opened between the high pressure fuel line and the combustion chamber (when it is at the peak of its compression ratio) enough alcohol will enter the combustion chamber to allow proper combustion. The overall advantages to this type of alcohol vaporization injection system is that it adds relatively few new mechanisms to the spark ignition four cycle internal combustion engine to enable it to operate as a diesel engine with a high thermal efficiency. This alcohol injection system exploits the engine's need for greater volumes of alcohol caused by the alcohol's relatively low heat of combustion (When compared to gasoline) by using this greater volume of fuel to return greater quantities of heat back to the engine to a much greater degree than other fuels can.

Bayley, R.I.

1980-05-06T23:59:59.000Z

436

Program plan for the resolution of tank vapor issues  

SciTech Connect (OSTI)

Since 1987, workers at the Hanford Site waste tank farms in Richland, Washington, have reported strong odors emanating from the large, underground high-level radioactive waste storage tanks. Some of these workers have complained of symptoms (e.g., headaches, nausea) related to the odors. In 1992, the U.S. Department of Energy, which manages the Hanford Site, and Westinghouse Hanford Company determined that the vapor emissions coming from the tanks had not been adequately characterized and represented a potential health risk to workers in the immediate vicinity of the tanks. At that time, workers in certain areas of the tank farms were required to use full-face, supplied-breathing-air masks to reduce their exposure to the fugitive emissions. While use of supplied breathing air reduced the health risks associated with the fugitive emissions, it introduced other health and safety risks (e.g., reduced field of vision, air-line tripping hazards, and heat stress). In 1992, an aggressive program was established to assure proper worker protection while reducing the use of supplied breathing air. This program focuses on characterization of vapors inside the tanks and industrial hygiene monitoring in the tank farms. If chemical filtration systems for mitigation of fugitive emissions are deemed necessary, the program will also oversee their design and installation. This document presents the plans for and approach to resolving the Hanford Site high-level waste tank vapor concerns. It is sponsored by the Department of Energy Office of Environmental Restoration and Waste Management.

Osborne, J.W.; Huckaby, J.L.

1994-05-01T23:59:59.000Z

437

The influence of prestrained metalorganic vapor phase epitaxial gallium-nitride templates on hydride vapor phase epitaxial growth  

Science Journals Connector (OSTI)

We have varied the strain situation in metalorganic vapor phase epitaxial (MOVPE) grown gallium-nitride (GaN) by exchanging the nucleation layer and by inserting a submono-Si x N y -interlayer in the first few hundred nanometers of growth on sapphire substrates. The influence on the MOVPE template and subsequent hydride vapor phase epitaxial (HVPE) growth could be shown by in-situ measurements of the sample curvature. Using the results of these investigations we have established a procedure to confine the curvature development in MOVPE and HVPE growth to a minimum. By increasing the layer thickness in HVPE we could create self-separated freestanding GaN layers with small remaining curvature.

2014-01-01T23:59:59.000Z

438

Tank 241-TX-118 headspace gas and vapor characterization results for samples collected in September 1994 and December 1994  

SciTech Connect (OSTI)

Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

Huckaby, J.L. [Pacific Northwest Lab., Richland, WA (United States); Bratzel, D.R. [Westinghouse Hanford Co., Richland, WA (United States)

1995-09-27T23:59:59.000Z

439

Headspace vapor characterization of Hanford Waste Tank 241-T-110: Results from samples collected on August 31, 1995. Tank Vapor Characterization Project  

SciTech Connect (OSTI)

This report describes the results of vapor samples taken from the headspace of waste storage tank 241-T-110 (Tank T-110) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5056. Samples were collected by WHC on August 31, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

McVeety, B.D.; Thomas, B.L.; Evans, J.C. [and others

1996-05-01T23:59:59.000Z

440

Final Report for ARM Project Measuring 4-D Water Vapor Fields with GPS  

SciTech Connect (OSTI)

Water vapor is a primary element in the Earth’s climate system. Atmospheric water vapor is central to cloud processes, radiation transfer, and the hydrological cycle. Using funding from Department of Energy (DOE) grant DE-FG03-02ER63327, the University Corporation for Atmospheric Research (UCAR) developed new observational techniques to measure atmospheric water vapor and applied these techniques to measure four dimensional water vapor fields throughout the United States Southern Great Plains region. This report summarizes the development of a new observation from ground based Global Positioning System (GPS) stations called Slant Water Vapor (SW) and it’s utilization in retrieving four dimensional water vapor fields. The SW observation represents the integrated amount of water vapor between a GPS station and a transmitting satellite. SW observations provide improved temporal and spatial sampling of the atmosphere when compared to column-integrated quantities such as preciptitable water vapor (PW). Under funding from the DOE Atmospheric Radiation Measurement (ARM) program, GPS networks in the Southern Great Plains (SGP) region were deployed to retrieve SW to improve the characterization of water vapor throughout the region. These observations were used to estimate four dimensional water vapor fields using tomographic approaches and through assimilation into the MM5 numerical weather model.

Braun, John

2006-02-06T23:59:59.000Z

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Mercury Vapor At Salt Wells Area (Henkle, Et Al., 2005) | Open Energy  

Open Energy Info (EERE)

Mercury Vapor At Salt Wells Area (Henkle, Et Al., 2005) Mercury Vapor At Salt Wells Area (Henkle, Et Al., 2005) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Salt Wells Area (Henkle, Et Al., 2005) Exploration Activity Details Location Salt Wells Area Exploration Technique Mercury Vapor Activity Date - 2005 Usefulness useful DOE-funding Unknown Exploration Basis Adsorbed mercury soil geochemical surveys and radiometric geophysical surveys were carried out in conjunction with geologic mapping to test the application of these ground-based techniques to geothermal exploration at three prospects in Nevada by Henkle Jr. et al. in 2005. Mercury soil vapor surveys were not widely used in geothermal exploration in the western US at the time, although the association of mercury vapors with geothermal

442

MEASUREMENTS AND RETRIEVALS FROM A NEW 183-GHz WATER VAPOR RADIOMETER IN  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

MEASUREMENTS AND RETRIEVALS FROM A NEW 183-GHz WATER VAPOR RADIOMETER IN MEASUREMENTS AND RETRIEVALS FROM A NEW 183-GHz WATER VAPOR RADIOMETER IN THE ARCTIC Cadeddu, Maria Argonne National Laboratory Category: Instruments A new G-band (183 GHz) vapor radiometer (GVR), developed and built by Prosensing Inc. (http://www.prosensing.com), was deployed in Barrow, Alaska, in April 2005. The radiometer was deployed as part of the ongoing Atmospheric Radiation Measurement (ARM) program's effort to improve water vapor retrievals in the cold, dry Arctic environment. The instrument measures brightness temperatures from four double sideband channels centered at 1, 3, 7, and 14 GHz from the 183.31-GHz water vapor line. Atmospheric emission in this spectral region is primarily due to water vapor, with some influence from liquid water. The GVR will remain in Barrow

443

Chemical vapor deposition of amorphous semiconductor films. Final subcontract report  

SciTech Connect (OSTI)

Chemical vapor deposition (CVD) from higher order silanes has been studied for fabricating amorphous hydrogenated silicon thin-film solar cells. Intrinsic and doped a-Si:H films were deposited in a reduced-pressure, tubular-flow reactor, using disilane feed-gas. Conditions for depositing intrinsic films at growth rates up to 10 A/s were identified. Electrical and optical properties, including dark conductivity, photoconductivity, activation energy, optical absorption, band-gap and sub-band-gap absorption properties of CVD intrinsic material were characterized. Parameter space for depositing intrinsic and doped films, suitable for device analysis, was identified.

Rocheleau, R.E.

1984-12-01T23:59:59.000Z

444

A thermoacoustic oscillator powered by vaporized water and ethanol  

Science Journals Connector (OSTI)

We measure the temperature difference required to drive a thermoacoustic oscillator containing air water vapor and liquid water as the working fluids. The oscillator is composed of a large tube containing an array of narrow tubes connected at one end to a tank of liquid water. When the water is heated the temperature difference across the tube array increases until thermoacoustic oscillations occur. The temperature difference at the onset of oscillation is measured to be 56 ? ° C significantly smaller (by ? 200 ? ° C ) than the temperature measured when the tank is filled with dry air instead of water. The temperature difference can be further reduced to 47 ? ° C by using ethanol instead of water.

Daisuke Noda; Yuki Ueda

2013-01-01T23:59:59.000Z

445

Io - Are vapor explosions responsible for the 5-micron outbursts  

SciTech Connect (OSTI)

It is proposed that a vapor explosion of a submerged pool of liquid sulfur will remove the crust overlying an area of about 50-km diam. Thermal radiation from the exposed liquid sulfur pool with a surface temperature of 600 K is then presumed to be responsible for the 5-micron outbursts that have been observed. The explosive volcanoes are expected to leave black sulfur calderas, which are, indeed, found on the surface. The 5-micron outburst observed by Sinton (1980), on June 11, 1979 (UT), is identified with a new caldera found on Voyager 2 photographs but which had not been present on Voyager 1 pictures.

Sinton, W.M.

1980-01-01T23:59:59.000Z

446

Optical waveguides in SBN by zinc vapor diffusion  

E-Print Network [OSTI]

at 600'C for a 12. 5 i1m Wide 1000'C Zinc Vapor Diffused SBN:60 Waveguide Measured at X = 0. 81 pm. IV. SBN:60 Amplitude Modulator Results . . . . . V. SBN:60 Mach-Zehnder Interferometer Results. . . . VI. Voltage-Length Product Comparison...: (a) extraordinary (TM), (b) 1. 5 x ordinary (TE). 12. Surface damage on SBN:60 diffused at 1000'C with an SiOz diffusion mask. 13. Zinc in-diffusion in SBN:60 25 . . . . . 26 . . . . . 27 . . . . . 28 29 14. Barium out-diffuison in SBN:60...

Quinn, Jeffrey Dale

1991-01-01T23:59:59.000Z

447

Combustion chemical vapor deposited coatings for thermal barrier coating systems  

SciTech Connect (OSTI)

The new deposition process, combustion chemical vapor deposition, shows a great deal of promise in the area of thermal barrier coating systems. This technique produces dense, adherent coatings, and does not require a reaction chamber. Coatings can therefore be applied in the open atmosphere. The process is potentially suitable for producing high quality CVD coatings for use as interlayers between the bond coat and thermal barrier coating, and/or as overlayers, on top of thermal barrier coatings. In this report, the evaluation of alumina and ceria coatings on a nickel-chromium alloy is described.

Hampikian, J.M.; Carter, W.B. [Georgia Institute of Technology, Atlanta, GA (United States). School of Materials Science and Engineering

1995-12-31T23:59:59.000Z

448

Unusual thermopower of inhomogeneous graphene grown by chemical vapor deposition  

SciTech Connect (OSTI)

We report on thermopower (TEP) and resistance measurements of inhomogeneous graphene grown by chemical vapor deposition (CVD). Unlike the conventional resistance of pristine graphene, the gate-dependent TEP shows a large electron-hole asymmetry. This can be accounted for by inhomogeneity of the CVD-graphene where individual graphene regions contribute with different TEPs. At the high magnetic field and low temperature, the TEP has large fluctuations near the Dirac point associated with the disorder in the CVD-graphene. TEP measurements reveal additional characteristics of CVD-graphene, which are difficult to obtain from the measurement of resistance alone.

Nam, Youngwoo, E-mail: youngwoo.nam@chalmers.se [Department of Physics and Astronomy, Seoul National University, Seoul 151-747 (Korea, Republic of); Department of Microtechnology and Nanoscience, Chalmers University of Technology, SE-412 96 Gothenburg (Sweden); Sun, Jie; Lindvall, Niclas; Yurgens, August [Department of Microtechnology and Nanoscience, Chalmers University of Technology, SE-412 96 Gothenburg (Sweden); Jae Yang, Seung; Rae Park, Chong [Department of Materials Science and Engineering, Seoul National University, Seoul 151-747 (Korea, Republic of); Woo Park, Yung [Department of Physics and Astronomy, Seoul National University, Seoul 151-747 (Korea, Republic of)

2014-01-13T23:59:59.000Z

449

Dosimeter for monitoring vapors and aerosols of organic compounds  

DOE Patents [OSTI]

A dosimeter is provided for collecting and detecting vapors and aerosols of organic compounds. The dosimeter comprises a lightweight, passive device that can be conveniently worn by a person as a badge or placed at a stationary location. The dosimeter includes a sample collector comprising a porous web treated with a chemical for inducing molecular displacement and enhancing phosphorescence. Compounds are collected onto the web by molecular diffusion. The web also serves as the sample medium for detecting the compounds by a room temperature phosphorescence technique. 7 figs.

Vo-Dinh, T.

1987-07-14T23:59:59.000Z

450

The Prospects of Alternatives to Vapor Compression Technology for Space Cooling and Food Refrigeration Applications  

SciTech Connect (OSTI)

Five alternatives to vapor compression technology were qualitatively evaluated to determine their prospects for being better than vapor compression for space cooling and food refrigeration applications. The results of the assessment are summarized in the report. Overall, thermoacoustic and magnetic technologies were judged to have the best prospects for competing with vapor compression technology, with thermotunneling, thermoelectric, and thermionic technologies trailing behind in that order.

Brown, Daryl R.; Dirks, James A.; Fernandez, Nicholas; Stout, Tyson E.

2010-03-31T23:59:59.000Z

451

A thermodynamics based analysis of exergy destruction in vapor compression cycle systems.  

E-Print Network [OSTI]

??In the last few decades, vapor-compression cycle systems (VCSs) have undergone many advances in actuation, allowing for variable aperture valves, variable speed compressors, and variable… (more)

Kania, Megan

2013-01-01T23:59:59.000Z

452

Synthesis and Characterization of Magnetic Nanowires Prepared by Chemical Vapor Deposition.  

E-Print Network [OSTI]

??Various metal silicide and germanide magnetic nanowires were synthesized using a home-built CVD [chemical vapor deposition] system. The morphology, composition, and magnetic properties of the… (more)

Tang, Siwei

2014-01-01T23:59:59.000Z

453

Liquid fuel vaporizer and combustion chamber having an adjustable thermal conductor  

DOE Patents [OSTI]

The efficiency and effectiveness of apparatuses for vaporizing and combusting liquid fuel can be improved using thermal conductors. For example, an apparatus having a liquid fuel vaporizer and a combustion chamber can be characterized by a thermal conductor that conducts heat from the combustion chamber to the vaporizer. The thermal conductor can be a movable member positioned at an insertion depth within the combustion chamber that corresponds to a rate of heat conduction from the combustion chamber to the vaporizer. The rate of heat conduction can, therefore, be adjusted by positioning the movable member at a different insertion depth.

Powell, Michael R; Whyatt, Greg A; Howe, Daniel T; Fountain, Matthew S

2014-03-04T23:59:59.000Z

454

Stable-Isotope Studies Of Rocks And Secondary Minerals In A Vapor...  

Open Energy Info (EERE)

Stable-Isotope Studies Of Rocks And Secondary Minerals In A Vapor-Dominated Hydrothermal System At The Geysers, Sonoma County, California Jump to: navigation, search GEOTHERMAL...

455

The Patuha geothermal system: a numerical model of a vapor-dominated system.  

E-Print Network [OSTI]

??The Patuha geothermal system is a vapor-dominated reservoir located about 40 kilometers southwest of Bandung on western Java, Indonesia. The geothermal system consists of a… (more)

Schotanus, M.R.J.

2013-01-01T23:59:59.000Z

456

E-Print Network 3.0 - alkali atom vapor Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

a vapor cell magneto-optical trap. 1999 American... to the vacuum pumps or due to adsorption of the ... Source: Jin, Deborah - JILA, University of Colorado at Boulder...

457

Removal of hydrogen sulfide as ammonium sulfate from hydropyrolysis product vapors  

SciTech Connect (OSTI)

A system and method for processing biomass into hydrocarbon fuels that includes processing a biomass in a hydropyrolysis reactor resulting in hydrocarbon fuels and a process vapor stream and cooling the process vapor stream to a condensation temperature resulting in an aqueous stream. The aqueous stream is sent to a catalytic reactor where it is oxidized to obtain a product stream containing ammonia and ammonium sulfate. A resulting cooled product vapor stream includes non-condensable process vapors comprising H.sub.2, CH.sub.4, CO, CO.sub.2, ammonia and hydrogen sulfide.

Marker, Terry L; Felix, Larry G; Linck, Martin B; Roberts, Michael J

2014-10-14T23:59:59.000Z

458

Response of passive organic vapor dosimeters to a mixed gas exposure  

E-Print Network [OSTI]

of Advisory Comm1ttee: Dr. Richard B. Konzen The effects of the sampling order of two chemicals adsorbed onto a DuPont Pro-Tek Organic Vapor Dosimeters were investigated. The dosimeters were exposed to varying known concentrations of methyl methacrylate...-powered pump to draw a known volume of air through a charcoal packed tube. The charcoal adsorbs the organic vapors and separates the small amount of vapor from a large amount of air. The organic vapors are then desorbed and analyzed by means of gas...

Anderson, Scott Merritt

2012-06-07T23:59:59.000Z

459

Low-Cost, Modular Electrothermal Vaporization System for Inductively Coupled Plasma Atomic Emission Spectrometry  

Science Journals Connector (OSTI)

In this investigation, commercially available tungsten filaments were employed to electrothermally vaporize liquid samples prior to their introduction into an inductively coupled...

Levine, Keith; Wagner, Karl A; Jones, Bradley T

1998-01-01T23:59:59.000Z

460

E-Print Network 3.0 - atomic vapor deposited Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Articles Surfactant-Catalyzed Chemical Vapor Deposition of Copper Thin Films Eui Seong Hwang... and demonstrated for deposition of copper thin films from ... Source:...

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

E-Print Network 3.0 - acoustic wave vapor Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

(6). While previous systems have demonstrated success in chemical... striking visual identification of a range of ligating vapors (including alcohols, amines, ethers... ,...

462

Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems.  

E-Print Network [OSTI]

??The Organic Flash Cycle (OFC) is proposed as a vapor power cycle that could potentially increase power generation and improve the utilization efficiency of renewable… (more)

Ho, Tony

2012-01-01T23:59:59.000Z

463

Towards improved spinnability of chemical vapor deposition generated multi-walled carbon nanotubes  

E-Print Network [OSTI]

P. J. F. 1999 Carbon nanotubes and related structures: newof vapor grown carbon nanotubes and single wall nanotubes, Eto Carbon Materials in Carbon Nanotubes: Preparation and

McKee, Gregg Sturdivant Burke

2008-01-01T23:59:59.000Z

464

Opals infiltrated with a stimuli-responsive hydrogel for ethanol vapor sensing  

Science Journals Connector (OSTI)

We report on a novel class of optical materials for ethanol vapor sensing, based on polystyrene opals infiltrated with an innovative stimuli-responsive hydrogel. We describe the...

Pernice, Riccardo; Adamo, Gabriele; Stivala, Salvatore; Parisi, Antonino; Busacca, Alessandro C; Spigolon, Dario; Sabatino, Maria Antonietta; D’Acquisto, Leonardo; Dispenza, Clelia

2013-01-01T23:59:59.000Z

465

Gas chromatographic-mass spectrometric characterization of an oil aerosol-vapor microbial disinfectant .  

E-Print Network [OSTI]

??"This thesis focuses on chemical characterization studies of disinfectant vapors generated from thermal oxidation of mineral oil and biogenic oil esters. The disinfection technique holds… (more)

Wadhwa, Prakash, 1980-

2005-01-01T23:59:59.000Z

466

Prediction of blast damage from vapor cloud explosions  

SciTech Connect (OSTI)

The process industries handle a wide range of different materials and use them in different types of chemical reaction. Of particular concern is the prospect of damage and injury affecting the general public outside the boundary wall of the chemical plant. It is not wise to permit the construction of homes, schools or hospitals so close to chemical plants that they, and the people within, might be damaged or injured should there be an accidental explosion in the plant. The major hazard outside the plant is over-pressure, a consequence of an accidental explosion in a cloud of flammable gas or vapor (Vapor Cloud Explosion or VCE). It is the responsibility of plant management to ensure that any such accidental explosion is not so large as to endanger the public, and of the local planning authorities to ensure that homes, schools or hospitals are not sited so close to chemical plants that they may be endangered by accidental explosion. A vital tool for such authorities is a simple method of assessing the possible consequences of an accidental VCE. In this paper those methods of assessing the consequences are examined.

Phillips, H. [Phillips (H.), Buxton (United Kingdom)

1995-12-31T23:59:59.000Z

467

Method of physical vapor deposition of metal oxides on semiconductors  

DOE Patents [OSTI]

A process for growing a metal oxide thin film upon a semiconductor surface with a physical vapor deposition technique in a high-vacuum environment and a structure formed with the process involves the steps of heating the semiconductor surface and introducing hydrogen gas into the high-vacuum environment to develop conditions at the semiconductor surface which are favorable for growing the desired metal oxide upon the semiconductor surface yet is unfavorable for the formation of any native oxides upon the semiconductor. More specifically, the temperature of the semiconductor surface and the ratio of hydrogen partial pressure to water pressure within the vacuum environment are high enough to render the formation of native oxides on the semiconductor surface thermodynamically unstable yet are not so high that the formation of the desired metal oxide on the semiconductor surface is thermodynamically unstable. Having established these conditions, constituent atoms of the metal oxide to be deposited upon the semiconductor surface are directed toward the surface of the semiconductor by a physical vapor deposition technique so that the atoms come to rest upon the semiconductor surface as a thin film of metal oxide with no native oxide at the semiconductor surface/thin film interface. An example of a structure formed by this method includes an epitaxial thin film of (001)-oriented CeO.sub.2 overlying a substrate of (001) Ge.

Norton, David P. (Knoxville, TN)

2001-01-01T23:59:59.000Z

468

Data:1d7a94b7-2b0e-4bef-a761-bbb08d023eb0 | Open Energy Information  

Open Energy Info (EERE)

b7-2b0e-4bef-a761-bbb08d023eb0 b7-2b0e-4bef-a761-bbb08d023eb0 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Richland, Washington (Utility Company) Effective date: 2013/01/01 End date if known: Rate name: Schedule 70: Security Lighting Area Lighting - Metered 400 Watt Mercury Vapor Sector: Lighting Description: A. Availability: In all territory served by the City's electric utility. B. Applicability: To all property owners or long-term leasees of property. C. Contract Provisions: The rates in this schedule apply to facilities consisting of overhead construction with mast arms and luminaries mounted on wood poles with lumen output as shown. Lighting facilities supplied under this schedule shall remain the property of the City, and shall be supplied only pursuant to a contract with the customer, the term of which shall be a period of not less than three (3) years. Pole Rental: When an individual wood pole is required on a new installation, the following monthly charges apply: 40 feet or less $ 1.00 Over 40 feet $ 1.00 plus $0.05 per foot Additional charge will be made for lamps installed seventy-five (75) feet or more above the ground.

469

Data:805506cc-4a91-4dce-b520-5e37d8d3f2f2 | Open Energy Information  

Open Energy Info (EERE)

cc-4a91-4dce-b520-5e37d8d3f2f2 cc-4a91-4dce-b520-5e37d8d3f2f2 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Ocmulgee Electric Member Corp Effective date: 1999/05/01 End date if known: Rate name: 100W Type -'Decorative HPS', kWh-40 Sector: Lighting Description: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaries and poles conforming to the Corporation's specifications. Service will be rendered only at locations that, solely in the opinion of the Corporation, are readily accessible for installation and maintenance. Source or reference: ISU Documentation

470

Data:24ee6a21-fec9-4440-9a3d-6659b37706f8 | Open Energy Information  

Open Energy Info (EERE)

a21-fec9-4440-9a3d-6659b37706f8 a21-fec9-4440-9a3d-6659b37706f8 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Richland, Washington (Utility Company) Effective date: 2013/01/01 End date if known: Rate name: Schedule 70: Security Lighting Area Lighting - Unmetered 400 Watt Mercury Vapor Sector: Lighting Description: A. Availability: In all territory served by the City's electric utility. B. Applicability: To all property owners or long-term leasees of property. C. Contract Provisions: The rates in this schedule apply to facilities consisting of overhead construction with mast arms and luminaries mounted on wood poles with lumen output as shown. Lighting facilities supplied under this schedule shall remain the property of the City, and shall be supplied only pursuant to a contract with the customer, the term of which shall be a period of not less than three (3) years. Pole Rental: When an individual wood pole is required on a new installation, the following monthly charges apply: 40 feet or less $ 1.00 Over 40 feet $ 1.00 plus $0.05 per foot Additional charge will be made for lamps installed seventy-five (75) feet or more above the ground.

471

Data:24a46b56-e904-42b4-b36b-763de7336934 | Open Energy Information  

Open Energy Info (EERE)

a46b56-e904-42b4-b36b-763de7336934 a46b56-e904-42b4-b36b-763de7336934 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Richland, Washington (Utility Company) Effective date: 2013/01/01 End date if known: Rate name: Schedule 70: Security Lighting Area Lighting - Unmetered 1,000 Watt Mercury Vapor Sector: Lighting Description: A. Availability: In all territory served by the City's electric utility. B. Applicability: To all property owners or long-term leasees of property. C. Contract Provisions: The rates in this schedule apply to facilities consisting of overhead construction with mast arms and luminaries mounted on wood poles with lumen output as shown. Lighting facilities supplied under this schedule shall remain the property of the City, and shall be supplied only pursuant to a contract with the customer, the term of which shall be a period of not less than three (3) years. Pole Rental: When an individual wood pole is required on a new installation, the following monthly charges apply: 40 feet or less $ 1.00 Over 40 feet $ 1.00 plus $0.05 per foot Additional charge will be made for lamps installed seventy-five (75) feet or more above the ground.

472

Investigation of Pool Spreading and Vaporization Behavior in Medium-Scale LNG Tests  

Science Journals Connector (OSTI)

Abstract A failure of a Liquefied Natural Gas (LNG) tanker can occur due to collision or loading/unloading operation resulting in spillage of LNG on water. Upon release, a spreading liquid can form a pool with rapid vaporization leading to the formation of a flammable vapor cloud. Safety analysis for the protection of public and property involves the determination of consequences of such accidental releases. To address this complex pool spreading and vaporization phenomenon of LNG, an investigation is performed based on the experimental tests that were conducted by the Mary Kay O’Connor Process Safety Center (MKOPSC) in 2007. The 2007 tests are a part of medium-scale experiments carried out at the Brayton Fire Training Field (BFTF), College Station. The dataset represents a semi-continuous spill on water, where LNG is released on a confined area of water for a specified duration of time. The pool spreading and vaporization behavior are validated using empirical models, which involved determination of pool spreading parameters and vaporization rates with respect to time. Knowledge of the pool diameter, pool height and spreading rate are found to be important in calculating the vaporization rates of the liquid pool. The paper also presents a method to determine the vaporization mass flux of LNG using water temperature data that is recorded in the experiment. The vaporization rates are observed to be high initially and tend to decrease once the pool stopped spreading. The results of the analysis indicated that a vaporization mass flux that is varying with time is required for accurate determination of the vaporization rate. Based on the data analysis, sources of uncertainties in the experimental data were identified to arise from ice formation and vapor blocking.

Nirupama Gopalaswami; R. Mentzer; M. Sam Mannan

2014-01-01T23:59:59.000Z

473

Evaluation of the Vaporization, Fusion, and Sublimation Enthalpies of the 1-Alkanols: The Vaporization Enthalpy of 1-, 6-, 7-, and 9-Heptadecanol,  

E-Print Network [OSTI]

Evaluation of the Vaporization, Fusion, and Sublimation Enthalpies of the 1-Alkanols* Department of Chemistry and Biochemistry, University of MissourisSt. Louis, St. Louis, Missouri 63121 sublimation enthalpies. The sublimation enthalpies were compared to existing literature values. Agreement

Chickos, James S.

474

Advanced Membrane Systems: Recovering Wasteful and Hazardous Fuel Vapors at the Gasoline Tank  

Broader source: Energy.gov (indexed) [DOE]

CMS to develop a membrane CMS to develop a membrane vapor processor that recovers fuel vapors from gasoline refueling with 99 percent efficiency. This membrane system enables gasoline stations to surpass environmental regulations while reducing fuel losses. Compact Membrane Systems, Inc. (CMS) was founded in 1993 in Wilmington, DE, with the acquisition of rights to certain DuPont polymer membrane patents. CMS focuses

475

An Examination of the Thermodynamics of Fusion, Vaporization, and Sublimation of Several Parabens by Correlation Gas  

E-Print Network [OSTI]

An Examination of the Thermodynamics of Fusion, Vaporization, and Sublimation of Several Parabens, Kasetsart University, Bangkane, Bangkok 10900, Thailand 2 Department of Chemistry and Biochemistry.com). DOI 10.1002/jps.22423 ABSTRACT: The vaporization, fusion, and sublimation enthalpies of methyl, ethyl

Chickos, James S.

476

Method and apparatus to measure vapor pressure in a flow system  

DOE Patents [OSTI]

The present invention is directed to a method for determining, by a condensation method, the vapor pressure of a material with a known vapor pressure versus temperature characteristic, in a flow system particularly in a mercury isotope enrichment process. 2 figures.

Grossman, M.W.; Biblarz, O.

1991-10-15T23:59:59.000Z

477

Apparatus and method for removing mercury vapor from a gas stream  

DOE Patents [OSTI]

A metallic filter effectively removes mercury vapor from gas streams. The filter captures the mercury which then can be released and collected as product. The metallic filter is a copper mesh sponge plated with a six micrometer thickness of gold. The filter removes up to 90% of mercury vapor from a mercury contaminated gas stream.

Ganesan, Kumar (Butte, MT)

2008-01-01T23:59:59.000Z

478

Determination of effective water vapor diffusion coefficient in pemfc gas diffusion layers  

E-Print Network [OSTI]

route from the cathode catalyst layer to the cathode flow channels. Water can be removed from the cellDetermination of effective water vapor diffusion coefficient in pemfc gas diffusion layers Jacob M: Water vapor diffusion PEMFC Water management GDL Diffusivity MPL a b s t r a c t The primary removal

Kandlikar, Satish

479

Optofluidic ring resonator sensors for rapid DNT vapor detection Greg Frye-Mason,b  

E-Print Network [OSTI]

(OFRR) chemical vapor sensor as a promising platform for explosive detection with the capability and chemical sensing platform.23­27 As illustrated in Fig. 1(A), the OFRR is a thin-walled fused silica shows that the OFRR vapor sensor is a promising platform for the development of a rapid, low

Fan, Xudong "Sherman"

480

Retrieval of water vapor profiles over ocean using SSM/I and SSM/T-2  

E-Print Network [OSTI]

of water vapor profiles, while the SSM/I can be used to retrieve, among other things, the total integrated water vapor (TIWV) in a column of air. It is theoretically possible to use SSM/I data to supplement the SSM/T-2 data, producing more accurate water...

Blankenship, Clay Bruce

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "vapor lamp luminaries" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Researchers develop electrodeposition process to deposit coatings on substrates, eliminate the expensive physical vapor  

E-Print Network [OSTI]

the expensive physical vapor deposition step, and improve device quality. CuIn1-xGaxSe2 (CIGS) solar cells have composition was adjusted by physical vapor deposition method. At present, we are fabricating CIGS-based solar). 2 R. N. Bhattacharya, W. Batchelor, J. F. Hiltner, and J. R. Sites, Appl. Phys. Lett., 75, 1431

482

Indium and tellurium doping of CdS crystals in cadmium vapor and their luminescent properties  

Science Journals Connector (OSTI)

A technique is devised for vapor-phase doping of CdS in the quaternary system Cd-In-Te-S. CdS crystals are doped with In and Te via four-zone ... InTe vapors. The luminescence spectra of the CdS?In,Te?[Cd] crysta...

I. N. Odin; M. V. Chukichev; M. E. Rubina

483

Indium and tellurium doping of CdS crystals in cadmium vapor and their luminescent properties  

Science Journals Connector (OSTI)

—A technique is devised for vapor-phase doping of CdS in the quaternary system Cd—In—Te—S. CdS crystals are doped with In and Te via four-zone ... InTe vapors. The luminescence spectra of the CdS?In,Te?[Cd] cryst...

I. N. Odin; M. V. Chukichev; M. E. Rubina

484

Vapor phase elemental sulfur amendment for sequestering mercury in contaminated soil  

DOE Patents [OSTI]

The process of treating elemental mercury within the soil is provided by introducing into the soil a heated vapor phase of elemental sulfur. As the vapor phase of elemental sulfur cools, sulfur is precipitated within the soil and then reacts with any elemental mercury thereby producing a reaction product that is less hazardous than elemental mercury.

Looney, Brian B.; Denham, Miles E.; Jackson, Dennis G.

2014-07-08T23:59:59.000Z

485

Nickel catalyst faceting in plasma-enhanced direct current chemical vapor deposition of carbon nanofibers  

E-Print Network [OSTI]

1 Nickel catalyst faceting in plasma-enhanced direct current chemical vapor deposition of carbon vapor deposition with Ni catalysts on the top of nanofibers. Transmission electron microscopy was used to study the morphology and crystallography of Ni catalysts, which are essential for the nucleation

Paris-Sud XI, Université de

486

Neural modeling of vapor compression refrigeration cycle with extreme learning machine  

Science Journals Connector (OSTI)

In this paper, a single-hidden layer feed-forward neural network (SLFN) is used to model the dynamics of the vapor compression cycle in refrigeration and air-conditioning systems, based on the extreme learning machine (ELM). It is shown that the assignment ... Keywords: Back propagation, Extreme learning machine, Modeling, Radial basis function, Support vector regression, Vapor compression refrigeration cycle

Lei Zhao; Wen-Jian Cai; Zhi-Hong Man

2014-03-01T23:59:59.000Z

487

Chem. Mater. 1995, 7, 2269-2272 2269 Water Vapor Adsorption on Chemically Treated  

E-Print Network [OSTI]

Chem. Mater. 1995, 7, 2269-2272 2269 Water Vapor Adsorption on Chemically Treated Activated Carbon August 25, 1995@ Water vapor adsorption on activated carbon cloth (ACCBO)which has been oxidized% Cl), and ACCBO (4% N), exhibits sigmoidal isotherms with hysteresis loops of varying magnitudes

Cal, Mark P.

488

Cloud and Aerosol Properties, Precipitable Water, and Profiles of Temperature and Water Vapor from MODIS  

E-Print Network [OSTI]

Cloud and Aerosol Properties, Precipitable Water, and Profiles of Temperature and Water Vapor from such as cloud mask, atmos- pheric profiles, aerosol properties, total precipitable water, and cloud properties vapor amount, aerosol particles, and the subsequently formed clouds [9]. Barnes et al. [2] provide

Sheridan, Jennifer

489

Tunneling characteristics in chemical vapor deposited graphene hexagonal boron nitride graphene junctions  

E-Print Network [OSTI]

1 Tunneling characteristics in chemical vapor deposited graphene ­ hexagonal boron nitride ­ graphene junctions T. Roy1 , L. Liu2 , S. de la Barrera,3 B. Chakrabarti1,4 , Z. R. Hesabi1 , C. A. Joiner1 Abstract: Large area chemical vapor deposited graphene and hexagonal boron nitride was used to fabricate

Feenstra, Randall

490

Computational Analysis and Optimization of a Chemical Vapor Deposition Reactor with  

E-Print Network [OSTI]

Computational Analysis and Optimization of a Chemical Vapor Deposition Reactor with Large and optimization of a three- dimensional model of a horizontal chemical vapor deposition (CVD) reactor used National Laboratories February 9, 2004 Abstract A computational analysis and optimization is presented

491

Optimization of the chemical vapor deposition process for carbon nanotubes fabrication  

E-Print Network [OSTI]

Optimization of the chemical vapor deposition process for carbon nanotubes fabrication M. Grujicica-phase chemistry and surface chemistry model is developed to analyze, at the reactor length scale, chemical vapor (carrier gas) in the presence of cobalt catalytic particles in a cylindrical reactor. The model allows

Grujicic, Mica

492

OPTIMAL DESIGN OF A HIGH PRESSURE ORGANOMETALLIC CHEMICAL VAPOR DEPOSITION REACTOR  

E-Print Network [OSTI]

OPTIMAL DESIGN OF A HIGH PRESSURE ORGANOMETALLIC CHEMICAL VAPOR DEPOSITION REACTOR K.J. BACHMANN of computer simulations as an optimal design tool which lessens the costs in time and effort in experimental vapor deposition (HPOMCVD) reactor for use in thin film crystal growth. The advantages of such a reactor

493

On the optimization of a dc arcjet diamond chemical vapor deposition reactor  

E-Print Network [OSTI]

On the optimization of a dc arcjet diamond chemical vapor deposition reactor S. W. Reevea) and W. A precursor in our dc arcjet reactor.1 Based on conclusions drawn from that work, an optimization strategy diamond film growth in a dc arcjet chemical vapor deposition reactor has been developed. Introducing

Dandy, David

494

Fundamental process and system design issues in CO2 vapor compression systems  

E-Print Network [OSTI]

Fundamental process and system design issues in CO2 vapor compression systems Man-Hoe Kima; CO2 (R-744); Transcritical cycle; Vapor compression system; COP; Air-conditioning; Heat pump recent developments and state of the art for transcritical CO2 cycle technology in various refrigeration

Bahrami, Majid

495

Laser vaporization/ionization interface for coupling microscale separation techniques with mass spectrometry  

DOE Patents [OSTI]

The present invention provides a laser-induced vaporization and ionization interface for directly coupling microscale separation processes to a mass spectrometer. Vaporization and ionization of the separated analytes are facilitated by the addition of a light-absorbing component to the separation buffer or solvent. 8 figs.

Yeung, E.S.; Chang, Y.C.

1999-06-29T23:59:59.000Z

496

Feasibility of UV lasing without inversion in mercury vapor  

E-Print Network [OSTI]

We investigate the feasibility of UV lasing without inversion at a wavelength of $253.7$ nm utilizing interacting dark resonances in mercury vapor. Our theoretical analysis starts with radiation damped optical Bloch equations for all relevant 13 atomic levels. These master equations are generalized by considering technical phase noise of the driving lasers. From the Doppler broadened complex susceptibility we obtain the stationary output power from semiclassical laser theory. The finite overlap of the driving Gaussian laser beams defines an ellipsoidal inhomogeneous gain distribution. Therefore, we evaluate the intra-cavity field inside a ring laser self-consistently with Fourier optics. This analysis confirms the feasibility of UV lasing and reveals its dependence on experimental parameters.

Martin R. Sturm; Benjamin Rein; Thomas Walther; Reinhold Walser

2014-06-27T23:59:59.000Z

497

Chemical vapor deposition of hydrogenated amorphous silicon from disilane  

SciTech Connect (OSTI)

The authors describe hydrogenated amorphous silicon (a-Si:H) thin films deposited at growth rates of 1 to 30 A/s by chemical vapor deposition (CVD) from disilane source gas at 24 torr total pressure in a tubular reactor. The effects of substrate temperature and gas holding time (flow rate) on film growth rate and effluent gas composition were measured at temperatures ranging from 360{sup 0} to 485{sup 0}C and gas holding times from 3 to 62s. Effluent gases determined by gas chromatography included silane, disilane and other higher order silanes. A chemical reaction engineering model, based on a silylene (SiH/sub 2/) insertion gas phase reaction network and film growth from both SiH/sub 2/ and high molecular weight silicon species, Si/sub n/H/sub 2n/, was developed. The model predictions were in good agreement with experimentally determined growth rates and effluent gas compositions.

Bogaert, R.J.; Russell, T.W.F.; Klein, M.T. (Delaware Univ., Newark, DE (USA). Dept. of Chemical Engineering); Rocheleau, R.E.; Baron, B.N. (Delaware Univ., Newark, DE (USA). Inst. of Energy Conversion)

1989-10-01T23:59:59.000Z

498

Chemical vapor deposition of boron-doped hydrogenated amorphous silicon  

SciTech Connect (OSTI)

Deposition conditions and film properties for a variety of boron-doped hydrogenated amorphous silicon films and silicon-carbon films produced by chemical vapor deposition (CVD) are discussed. Deposition gases include monosilane, disilane, trisilane, and acetylene. Two types of optically wide band-gap p layers are obtained. One of these window p layers (without carbon) has been extensively tested in photovoltaic devices. Remarkably, this p layer can be deposited between about 200 to 300 /sup 0/C. A typical open circuit voltage in an all CVD p-i-n device is 0.70--0.72 V, and in a hybrid device where the i and n layers are deposited by glow discharge, 0.8--0.83 V.

Ellis F.B. Jr.; Delahoy, A.E.

1985-07-15T23:59:59.000Z

499

Adsorption and Diffusion of Alcohol Vapors by Argonne Premium Coals  

Science Journals Connector (OSTI)

Adsorption and Diffusion of Alcohol Vapors by Argonne Premium Coals ... Adsorption of methanol, ethanol, n-propanol, and n-butanol by Pocahontas No. 3, Upper Freeport, Illinois No. 6, and Beulah-Zap Argonne premium coals was investigated to clarify the effect of alkyl group bulk on adsorption and to evaluate the micropore and cross-linked structure of coals. ... Coals are thought to have a large surface area with an interconnected network of slitlike pores.1 However, Larsen et al.2 measured the adsorption of various gases on five Argonne Premium coals and, except for Beulah-Zap lignite, found that the very steep dependence of BET surface area was related to the molecular volume of the gas. ...

Toshimasa Takanohashi; Yuki Terao; Takahiro Yoshida; Masashi Iino

2000-06-17T23:59:59.000Z

500

Homogeneous nucleation rate measurements in supersaturated water vapor  

Science Journals Connector (OSTI)

The rate of homogeneous nucleation in supersaturated vapors of water was studied experimentally using a thermal diffusion cloud chamber. Helium was used as a carrier gas. Our study covers a range of nucleation rates from 3 × 10 ? 1 to 3 × 10 2 cm ? 3 s ? 1 at four isotherms: 290 300 310 and 320 K . The molecular content of critical clusters was estimated from the slopes of experimental data. The measured isothermal dependencies of nucleation rate of water on saturation ratio were compared with the prediction of the classical theory of homogeneous nucleation the empirical prediction of Wölk et al. [J. Chem. Phys.117 10 (2002)] the scaled model of Hale [Phys. Rev. A33 4156 (1986)] and the former nucleation onset data.

David Brus; Vladimír Ždímal; Ji?í Smolík

2008-01-01T23:59:59.000Z