National Library of Energy BETA

Sample records for type j1772 test

  1. Lessons learned during Type A Packaging testing

    SciTech Connect (OSTI)

    O`Brien, J.H.; Kelly, D.L.

    1995-11-01

    For the past 6 years, the US Department of Energy (DOE) Office of Facility Safety Analysis (EH-32) has contracted Westinghouse Hanford Company (WHC) to conduct compliance testing on DOE Type A packagings. The packagings are tested for compliance with the U.S. Department of Transportation (DOT) Specification 7A, general packaging, Type A requirements. The DOE has shared the Type A packaging information throughout the nuclear materials transportation community. During testing, there have been recurring areas of packaging design that resulted in testing delays and/or initial failure. The lessons learned during the testing are considered a valuable resource. DOE requested that WHC share this resource. By sharing what is and can be encountered during packaging testing, individuals will hopefully avoid past mistakes.

  2. Low-voltage switchgear and controlgear assemblies: part 1: type-tested and partially type-tested assemblies

    E-Print Network [OSTI]

    International Electrotechnical Commission. Geneva

    2004-01-01

    Low-voltage switchgear and controlgear assemblies: part 1: type-tested and partially type-tested assemblies

  3. FRC Performance Comparison: Direct Tensile Test, FRC Performance Comparison: Direct Tensile Test, BeamBeamType Bending Test, and Round Panel TestType Bending Test, and Round Panel Test

    E-Print Network [OSTI]

    Chao, Shih-Ho

    FRC Performance Comparison: Direct Tensile Test, FRC Performance Comparison: Direct Tensile Test, BeamBeamType Bending Test, and Round Panel TestType Bending Test, and Round Panel Test ShihShihHo ChaoTo compare the performance of FRC materials when evaluated by three major types of material tests (Unia ial

  4. Results from the Operational Testing of the Eaton Smart Grid Capable Electric Vehicle Supply Equipment

    SciTech Connect (OSTI)

    Bennett, Brion

    2014-10-01

    The Idaho National Laboratory conducted testing and analysis of the Eaton smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from Eaton for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the Eaton smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

  5. Results from the Operational Testing of the General Electric Smart Grid Capable Electric Vehicle Supply Equipment (EVSE)

    SciTech Connect (OSTI)

    Richard Barney Carlson; Don Scoffield; Brion Bennett

    2013-12-01

    The Idaho National Laboratory conducted testing and analysis of the General Electric (GE) smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from GE for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the GE smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

  6. Long Duration Testing of Type C Thermocouples at 1500 °C

    SciTech Connect (OSTI)

    Joy L. Rempe; Darrell L. Knudson; J. E. Daw; S. C. Wilkins

    2008-04-01

    Experience with Type C thermocouples operating for long periods in the 1400 to 1600 °C temperature range indicate that significant decalibration occurs, often leading to expensive downtime and material waste. As part of an effort to understand the mechanisms causing drift in these thermocouples, the Idaho National Laboratory conducted a long duration test at 1500 °C containing eight Type C thermocouples. As report in this document, results from this long duration test were adversely affected due to oxygen ingress. Nevertheless, results provide key insights about the impact of precipitate formation on thermoelectric response. Post-test examinations indicate that thermocouple signal was not adversely impacted by the precipitates detected after 1,000 hours of heating at 1,500 °C and suggest that the signal would not have been adversely impacted by these precipitates for longer durations (if oxygen ingress had not occurred in this test).

  7. EARLY TESTS OF DRUM TYPE PACKAGINGS - THE LEWALLEN REPORT

    SciTech Connect (OSTI)

    Smith, A.

    2010-07-29

    The need for robust packagings for radioactive materials (RAM) was recognized from the earliest days of the nuclear industry. The U.S. Department of Energy (DOE) Rocky Flats Plant developed a packaging for shipment of Pu in the early 1960's, which became the U.S. Department of Transportation (DOT) 6M specification package. The design concepts were employed in other early packagings. Extensive tests of these at Savannah River Laboratory (now Savannah River National Laboratory) were performed in 1969 and 1970. The results of these tests were reported in 'Drum and Board-Type Insulation Overpacks of Shipping Packages for Radioactive Materials', by E. E. Lewallen. The Lewallen Report was foundational to design of subsequent drum type RAM packaging. This paper summarizes this important early study of drum type packagings. The Lewallen Report demonstrated the ability packagings employing drum and insulation board overpacks and engineered containment vessels to meet the Type B package requirements. Because of the results of the Lewallen Report, package designers showed high concern for thermal protection of 'Celotex'. Subsequent packages addressed this by following strategies like those recommended by Lewallen and by internal metal shields and supplemental, encapsulated insulation disks, as in 9975. The guidance provide by the Lewallen Report was employed in design of a large number of drum size packagings over the following three decades. With the increased public concern over transportation of radioactive materials and recognition of the need for larger margins of safety, more sophisticated and complex packages have been developed and have replaced the simple packagings developed under the Lewallen Report paradigm.

  8. Apparatus for tensile testing plate-type ceramic specimens

    DOE Patents [OSTI]

    Liu, K.C.

    1993-08-24

    Apparatus is described for gripping a plate-type tensile specimen having generally T-shaped end regions in a dynamic tension fatigue testing apparatus comprising an annular housing having an open-ended elongated cavity therein, a plurality of hydraulic piston means supported by the housing in a spaced array about the cavity, and a specimen-supporting plate means overlying the piston means at one end of the elongated cavity and displaceable by said piston means in a longitudinal direction with respect to the longitudinal axis of the cavity, said apparatus for gripping a flat plate-type tensile specimen comprising: a pair of elongated pull rods each having oppositely disposed first and second end regions; a pair of mounting means carried by said plate means with each mounting means for pivotally attaching the first end region of each of said pull rods in a central region of said plate means for supporting said pair of elongated pull rods in a side-by-side relationship along a common longitudinal centerline within said cavity; recess means in the second end region of each of said pull rods in adjacently disposed surface regions thereof with said recess means facing one another and each adapted to receive one side of one of the generally T-shaped end regions of the plate-type tensile specimen; and load-bearing means positionable in each of said recess means and adapted to bear against a shoulder on each side of the generally T-shaped end region of the plate-type tensile specimen when a tensile loading is applied thereon.

  9. Testing Doppler type shift for an accelerated source and determination of the universal maximal acceleration

    E-Print Network [OSTI]

    Yaakov Friedman

    2010-06-10

    An experiment for testing Doppler type shift for an accelerated source and determination of the universal maximal acceleration is proposed.

  10. SPERT Destructive Test - I on Aluminum, Highly Enriched Plate Type Core

    SciTech Connect (OSTI)

    2011-04-05

    SPERT - Special Power Excursion Reactor Tests Destructive Test number 1 On Aluminum, Highly Enriched Plate Type Core. A test studying the behavior of the reactor under destructive conditions on a light water moderated pool-type reactor with a plate-type core.

  11. SPERT Destructive Test - I on Aluminum, Highly Enriched Plate Type Core

    ScienceCinema (OSTI)

    None

    2014-05-07

    SPERT - Special Power Excursion Reactor Tests Destructive Test number 1 On Aluminum, Highly Enriched Plate Type Core. A test studying the behavior of the reactor under destructive conditions on a light water moderated pool-type reactor with a plate-type core.

  12. Supporting dependently typed functional programming with proof automation and testing 

    E-Print Network [OSTI]

    Wilson, Sean

    2011-06-30

    Dependent types can be used to capture useful properties about programs at compile time. However, developing dependently typed programs can be difficult in current systems. Capturing interesting program properties usually ...

  13. GHZ-type and W-type entangled coherent states: generation and Bell-type inequality tests without photon counting

    E-Print Network [OSTI]

    Hyunseok Jeong; Nguyen Ba An

    2006-07-12

    We study GHZ-type and W-type three-mode entangled coherent states. Both the types of entangled coherent states violate Mermin's version of the Bell inequality with threshold photon detection (i.e., without photon counting). Such an experiment can be performed using linear optics elements and threshold detectors with significant Bell violations for GHZ-type entangled coherent states. However, to demonstrate Bell-type inequality violations for W-type entangled coherent states, additional nonlinear interactions are needed. We also propose an optical scheme to generate W-type entangled coherent states in free-traveling optical fields. The required resources for the generation are a single-photon source, a coherent state source, beam splitters, phase shifters, photodetectors, and Kerr nonlinearities. Our scheme does not necessarily require strong Kerr nonlinear interactions, i.e., weak nonlinearities can be used for the generation of the W-type entangled coherent states. Furthermore, it is also robust against inefficiencies of the single-photon source and the photon detectors.

  14. Corrosion testing of Type 304L stainless steel for waste tank applications

    SciTech Connect (OSTI)

    Wiersma, B.J.; Mickalonis, J.I.

    1991-01-01

    AISI Type 304L stainless steel will be the material of construction for hazardous waste storage tanks. The corrosion behavior of 304L was characterized in simulated waste solutions using potentiodynamic polarization, electrochemical impedance spectroscopy and long term immersion tests. The results were correlated to assess the use of corrosion characteristics determined by electrochemical techniques for predicting long term corrosion behavior. The corrosion behaviors of Type A537 carbon steel and Incoloy 825 were also evaluated. A good correlation was found between the results from the electrochemical techniques and the immersion tests.

  15. Corrosion testing of Type 304L stainless steel for waste tank applications

    SciTech Connect (OSTI)

    Wiersma, B.J.; Mickalonis, J.I.

    1991-12-31

    AISI Type 304L stainless steel will be the material of construction for hazardous waste storage tanks. The corrosion behavior of 304L was characterized in simulated waste solutions using potentiodynamic polarization, electrochemical impedance spectroscopy and long term immersion tests. The results were correlated to assess the use of corrosion characteristics determined by electrochemical techniques for predicting long term corrosion behavior. The corrosion behaviors of Type A537 carbon steel and Incoloy 825 were also evaluated. A good correlation was found between the results from the electrochemical techniques and the immersion tests.

  16. 9978 AND 9975 TYPE B PACKAGING INTERNAL DATA COLLECTION FEASIBILITY TESTING

    SciTech Connect (OSTI)

    Fogle, R.

    2012-05-07

    The objective of this report is to document the findings from a series of proof-of-concept tests performed by Savannah River National Laboratory (SRNL) R and D Engineering, for the DOE Packaging Certification Program to determine if a viable radio link could be established from within the stainless steel confines of several drum-style DOE certified Type B radioactive materials packagings. Two in-hand, off-the-shelf radio systems were tested. The first system was a Wi-Fi Librestream Onsight{trademark} camera with a Fortress ES820 Access Point and the second was the On-Ramp Wireless Ultra-Link Processing{trademark} (ULP) radio system. These radio systems were tested within the Model 9975 and 9978 Type B packagings at the SRNL. This report documents the test methods and results. A path forward will also be recommended.

  17. Generalized Multivariate Rank Type Test Statistics via Spatial U-Quantiles

    E-Print Network [OSTI]

    Serfling, Robert

    Generalized Multivariate Rank Type Test Statistics via Spatial U-Quantiles Weihua Zhou1 University for location have been extended over the years to the multivariate setting, including recent robust rotation invariant "spatial" versions. Here we introduce a broad class of rotation invariant multivariate spatial

  18. Test and evaluation document for DOT Specification 7A Type A Packaging. Revision 3

    SciTech Connect (OSTI)

    1996-01-30

    The US Department of Energy (DOE) has been conducting, through several of its operating contractors, an evaluation and testing program to qualify Type A radioactive material packagings per US Department of Transportation (DOT) Specification 7A (DOT-7A) of the Code of Federal Regulations (CFR), Title 49, Part 178 (49 CFR 178). The program is currently administered by the DOE, Office of Facility Safety Analysis, DOE/EH-32, at DOE-Headquarters (DOE-HQ) in Germantown, Maryland. This document summarizes the evaluation and testing performed for all of the packagings successfully qualified in this program.

  19. Irradiation tests of ITER candidate Hall sensors using two types of neutron spectra

    SciTech Connect (OSTI)

    Duran, I. [Institute of Plasma Physics AS CR, v. v. i., Association EURATOM/IPP.CR, 182 00 Prague 8 (Czech Republic); Bolshakova, I.; Holyaka, R. [Magnetic Sensor Laboratory, Lviv Polytechnic National University, 790 31 Lviv (Ukraine); Viererbl, L.; Lahodova, Z. [Nuclear Research Institute plc., 250 68 Husinec-Rez (Czech Republic); Sentkerestiova, J. [Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, 115 19 Prague 1 (Czech Republic); Bem, P. [Nuclear Physics Institute AS CR, v. v. i., 250 68 Husinec-Rez (Czech Republic)

    2010-10-15

    We report on irradiation tests of InSb based Hall sensors at two irradiation facilities with two distinct types of neutron spectra. One was a fission reactor neutron spectrum with a significant presence of thermal neutrons, while another one was purely fast neutron field. Total neutron fluence of the order of 10{sup 16} cm{sup -2} was accumulated in both cases, leading to significant drop of Hall sensor sensitivity in case of fission reactor spectrum, while stable performance was observed at purely fast neutron spectrum. This finding suggests that performance of this particular type of Hall sensors is governed dominantly by transmutation. Additionally, it further stresses the need to test ITER candidate Hall sensors under neutron flux with ITER relevant spectrum.

  20. Fabrication and Performance Tests of a Segmented P-Type HPGe Detector

    E-Print Network [OSTI]

    George S. King III; Frank T. Avignone III; Christopher E. Cox; Todd W. Hossbach; Wayne Jennings; James H. Reeves

    2007-05-31

    A p-type HPGe detector has been segmented by cutting, with a diamond saw, and etching six circumferential grooves through the Li-diffused dead layer. The degree of segmentation was tested with the 88 keV gamma rays from a well-collimated source of 109Cd. The fraction of events, recognized as occurring in more than one segment, and rejected from the energy interval 2038 +/- 5 keV, was measured as 0.59.

  1. Test and evaluation document for DOT Specification 7A type A packaging. Volume 1

    SciTech Connect (OSTI)

    Kelly, D L

    1997-08-04

    The US Department of Energy (DOE) has been conducting, through several of its operating contractors, an evaluation and testing program to qualify Type A radioactive material packagings per US Department of Transportation (DOT) Specification 7A (DOT-7A) of the Code of Federal Regulations (CFR), Title 49, Part 178 (49 CFR 178). This document summarizes the evaluation and testing performed for all of the packagings successfully qualified in this program. This document supersedes DOE Evaluation Document for DOT-7A Type A Packaging (Edling 1987), originally issued in 1987 by Monsanto Research Corporation Mound Laboratory (MLM), Miamisburg, Ohio, for the Department of Energy, Security Evaluation Program (I)P-4. Mound Laboratory issued four revisions to the document between November 1988 and December 1989. In September 1989, the program was transferred to Westinghouse Hanford Company (Westinghouse Hanford) in Richland, Washington. One additional revision was issued in March 1990 by Westinghouse Hanford. This revision reflects the earlier material and incorporates a number of changes. Evaluation and testing activities on 1208 three DOT-7A Program Dockets resulted in the qualification of three new packaging configurations, which are incorporated herein and summarized. This document presents approximately 300 different packagings that have been determined to meet the requirements for a DOT-7A, type A packaging per 49 CFR 178.350.

  2. Development and test of a rectangular CERN ConFlat-type flange

    E-Print Network [OSTI]

    Miarnau Marin, Ana; Veness, Raymond

    2015-01-01

    Standard circular ConFlat® (CF) flanges are widely used in industry due to their high sealing reliability after being subjected to a bakeout process. The Beam Gas Ionisation (BGI) instrument for the CERN Proton Synchrotron accelerator will require a CF-like rectangular sealing system. Although rectangular CF-type flanges with plastically deforming metal seals have been used, no published designs with validated tests for bakeout under UHV conditions are available. Existing circular CERN CF flanges were compared and a design for a rectangular CF flange was proposed. Two prototypes were manufactured along with copper gaskets. The flanges and gaskets were cleaned and prepared for extensive vacuum testing after bakeout cycles up to 350 °C. This paper summarises the design, analysis and manufacturing process and describes the testing procedures and results. Additionally, the limitations when designing a flange of any shape were explored.

  3. Test Plan for Westinghouse Hanford Company`s Hedgehog Shielded Container, Docket 94-39-7A, Type A Container

    SciTech Connect (OSTI)

    Kelly, D.L.

    1995-02-27

    This report documents the US Department of Transportation Specification 7A Type A (DOT-7A) compliance testing to be followed for qualification of the Westinghouse Hanford Company`s Hedgehog Shielded Container for use as a Type A packaging. The packaging configurations being tested are intended for liquids and solids, and for air transportation.

  4. TEST & EVALUATION REPORT FOR THE HEDGEHOG-II PACKAGING SYSTEMS DOT-7A TYPE A CONTAINER

    SciTech Connect (OSTI)

    KELLY, D.L.

    2003-12-29

    This report documents the US. Department of Transportation Specification 7A (DOT-7A) Type A compliance test and evaluation results for the Hedgehog-II packaging systems. The approved Hedgehog-II packaging configurations provide primary and secondary containment. The approved packaging configurations described within this report are designed to ship Type A quantities of radioactive materials, normal form. Contents may be in solid or liquid form. Liquids transported in the approved 1 L glass bottle assembly shall have a specific gravity of less than or equal to 1.6. Liquids transported in all other approved configurations shall have a specific gravity of less than or equal to 2.0. The solid contents, including packaging, are limited in weight to the gross weight of the as-tested liquids and bottles. The approved Hedgehog-II packaging configurations described in this report may be transported by air, and have been evaluated as meeting the applicable International Air Transport Association/International Civil Aviation Organization (IATA/ICAO) Dangerous Goods Regulations in addition to the DOT requirements.

  5. A Test for the Nature of the Type Ia Supernova Explosion Mechanism

    E-Print Network [OSTI]

    Philip A. Pinto; Ronald G. Eastman; Tamara Rogers

    2000-08-21

    Currently popular models for Type Ia supernovae (SNe Ia) fall into two general classes. The first comprises explosions of nearly pure carbon/oxygen (C/O) white dwarfs at the Chandrasekhar limit which ignite near their centers. The second consists of lower-mass C/O cores which are ignited by the detonation of an accreted surface helium layer. Explosions of the latter type produce copious Fe, Co and Ni K-alpha emission from 56Ni and 56Co decay in the detonated surface layers, emission which is much weaker from Chandrasekhar-mass models. The presence of this emission provides a simple and unambiguous discriminant between these two models for SNe Ia. Both mechanisms may produce 0.1-0.6 solar masses of 56Ni, making them bright gamma-ray line emitters. The time to maximum brightness of 56Ni decay lines is distinctly shorter in the sub-Chandrasekhar mass class of model (approximately 15 days) than in the Chandrasekhar mass model (approximately 30 days), making gamma-ray line evolution another direct test of the explosion mechanism. It should just be possible to detect K-shell emission from a sub-Chandrasekhar explosion from SNe Ia as far away as the Virgo cluster with the XMM Observatory. A 1 to 2 square meter X-ray telescope such as the proposed Con-X Observatory could observe K-alpha emission from sub-Chandrasekhar mass SNe Ia in the Virgo cluster, providing not just a detection, but high-accuracy flux and kinematic information.

  6. A Test of Tully-Fisher Distance Estimates Using Cepheids and Type Ia Supernovae

    E-Print Network [OSTI]

    T. Shanks

    1999-01-24

    We update and extend the results of Shanks (1997, MNRAS, 290, L77) by making a direct test of Tully-Fisher distance estimates to thirteen spiral galaxies with HST Cepheid distances and to ten spiral galaxies with Type Ia supernova (SNIa) distances. The results show that the Tully-Fisher distance moduli are too short with respect to the Cepheid distances by 0.46+-0.11mag and too short with respect to the SNIa distances by 0.49+-0.18mag. Combining the HST Cepheid and the best SNIa data suggests that, overall, previous Tully-Fisher distances at v~1000 kms-1 were too short by 0.43+-0.09mag, a result which is significant at the 4.6 sigma level. These data therefore indicate that previous Tully-Fisher distances should be revised upwards by 22+-5% implying, for example, a Virgo distance of 19.0+-1.8Mpc. The value of Ho from Tully-Fisher estimates is correspondingly revised downwards from Ho=84+-10kms-1Mpc-1 to Ho=69+-8kms-1Mpc-1. There is evidence that the Tully-Fisher relation at large distances is affected by Malmquist bias. In this case, we argue that Ho<50kms-1Mpc-1 cannot be ruled out by Tully-Fisher considerations.

  7. MyUni Tests Tests.............................................................................................................................................. 2

    E-Print Network [OSTI]

    Balasuriya, Sanjeeva

    MyUni ­ Tests Tests.............................................................................................................................................. 2 Test question types.................................................................................................................... 2 Create a test

  8. A Multiplex PCR Test for Determination of Mating Type Applied to the Plant Pathogens Tapesia

    E-Print Network [OSTI]

    Pappu, Hanu R.

    mating type (Coppin et al., 1997; Po¨ggeler and Ku¨ck, 2000). These idiomorphs are flanked by regions

  9. Final evaluation & test report for the standard waste box (docket 01-53-7A) type A packaging

    SciTech Connect (OSTI)

    KELLY, D L

    2001-10-15

    This report documents the U.S. Department of Transportation Specification 7A Type A compliance test and evaluation results of the Standard Waste Box. Testing and evaluation activities documented herein are on behalf of the U.S. Department of Energy-Headquarters, Office of Safety, Health and Security (EM-5), Germantown, Maryland. Duratek Federal Services, Inc., Northwest Operations performed an evaluation of the changes as documented herein under Docket 01-53-7A.

  10. Final evaluation & test report for the standard waste box (docket 01-53-7A) type A packaging

    SciTech Connect (OSTI)

    KELLY, D.L.

    2001-08-15

    This report documents the U.S. Department of Transportation Specification 7A Type A (DOT-7A) compliance test and evaluation results of the Standard Waste Box (SWB). Testing and evaluation activities documented herein are on behalf of the U.S. Department of Energy-Headquarters (DOE-HQ), Office of Safety, Health and Security (EM-5), Germantown, Maryland. Dwatek Federal Services, Inc., Northwest Operations (DFSNW) performed an evaluation of the changes as documented herein under Docket 01-53-7A.

  11. Analysis of side end pressurized bump type gas foil bearings: a model anchored to test data 

    E-Print Network [OSTI]

    Kim, Tae Ho

    2009-05-15

    Comprehensive modeling of gas foil bearings (GFBs) anchored to reliable test data will enable the widespread usage of GFBs into novel turbomachinery applications, such as light weight business aircraft engines, hybrid fuel cell-turbine power systems...

  12. Test Plan for Lockheed Idaho Technologies Company (LITCO), ARROW-PAK Packaging, Docket 95-40-7A, Type A Container

    SciTech Connect (OSTI)

    Kelly, D.L.

    1995-10-23

    This report documents the U.S. Department of Transportation Specification 7A Type A (DOT-7A) compliance testing to be followed for qualification of the Lockheed Idaho Technologies Company, ARROW-PAK, for use as a Type A Packaging. The packaging configuration being tested is intended for transportation of radioactive solids, Form No. 1, Form No. 2, and Form No. 3.

  13. Crack-arrest tests on two irradiated high-copper welds. Phase 2: Results of duplex-type experiments

    SciTech Connect (OSTI)

    Iskander, S.K.; Corwin, W.R.; Nanstad, R.K. [Oak Ridge National Lab., TN (United States)

    1994-03-01

    The objective of the Heavy-Section Steel Irradiation Program Sixth Irradiation Series is to determine the effect of neutron irradiation on the shift and shape of the lower-bound curve to crack-arrest toughness data. Two submerged-arc welds with copper contents of 0.23 and 0.31 wt % were commercially fabricated in 220-mm-thick plate. Crack-arrest specimens fabricated from these welds were irradiated at a nominal temperature of 288{degrees}C to an average fluence of 1.9 {times} 10{sup 19} neutrons/cm{sup 2} (>1 MeV). This is the second report giving the results of the tests on irradiated duplex-type crack-arrest specimens. A previous report gave results of tests on irradiated weld-embrittled-type specimens. Charpy V-notch (CVN) specimens irradiated in the same capsules as the crack-arrest specimens were also tested, and a 41-J transition temperature shift was determined from these specimens. {open_quotes}Mean{close_quote} curves of the same form as the American Society of Mechanical Engineers (ASME) K{sub la} curve were fit to the data with only the {open_quotes}reference temperature{close_quotes} as a parameter. The shift between the mean curves agrees well with the 41-J transition temperature shift obtained from the CVN specimen tests. Moreover, the four data points resulting from tests on the duplex crack-arrest specimens of the present study did not make a significant change to mean curve fits to either the previously obtained data or all the data combined.

  14. TESTING THE METAL OF LATE-TYPE KEPLER PLANET HOSTS WITH IRON-CLAD METHODS

    SciTech Connect (OSTI)

    Mann, Andrew W.; Hilton, Eric J.; Gaidos, Eric; Kraus, Adam

    2013-06-10

    It has been shown that F, G, and early K dwarf hosts of Neptune-sized planets are not preferentially metal-rich. However, it is less clear whether the same holds for late K and M dwarf planet hosts. We report metallicities of Kepler targets and candidate transiting planet hosts with effective temperatures below 4500 K. We use new metallicity calibrations to determine [Fe/H] from visible and near-infrared spectra. We find that the metallicity distribution of late K and M dwarfs monitored by Kepler is consistent with that of the solar neighborhood. Further, we show that hosts of Earth- to Neptune-sized planets have metallicities consistent with those lacking detected planets and rule out a previously claimed 0.2 dex offset between the two distributions at 6{sigma} confidence. We also demonstrate that the metallicities of late K and M dwarfs hosting multiple detected planets are consistent with those lacking detected planets. Our results indicate that multiple terrestrial and Neptune-sized planets can form around late K and M dwarfs with metallicities as low as 0.25 solar. The presence of Neptune-sized planets orbiting such low-metallicity M dwarfs suggests that accreting planets collect most or all of the solids from the disk and that the potential cores of giant planets can readily form around M dwarfs. The paucity of giant planets around M dwarfs compared to solar-type stars must be due to relatively rapid disk evaporation or a slower rate of planet accretion, rather than insufficient solids to form a core.

  15. Test plan for the M-100 container, (model M-101/7A/12/90) docket 96-43-7A, type A container. Revision 1

    SciTech Connect (OSTI)

    Kelly, D.L.

    1997-07-22

    This report concerns the packaging configurations being tested by the U.S. DOE and its contractors, and according to U.S. DOT specification 7A Type A (DOT-7A) requirements. The objective of this Test Plan is to describe the testing for the qualification of the M-100 Container, Model M-101/7A/12/90 as a DOT-7A Type A packaging. This packaging system is designed to ship Type A solid radioactive materials, normal form, Form Number 1, Form Number 2, and Form Number 3.

  16. Test and evaluation report for Westinghouse Hanford Company`s 1-L liquid shipper, docket 95-41-7A, Type A container

    SciTech Connect (OSTI)

    Kelly, D.L.

    1996-03-13

    This report incorporates the U.S. Department of Energy, Office of Facility Safety Analysis (DOE/EH-32) approval letter for packaging use. This report documents the U.S. Department of Transportation Specification 7A Type A (DOT-7A) compliance test results of the 1-L Liquid Shipper packaging. The approved packaging system is designed to ship Type A quantities of radioactive materials, normal form. Contents may be liquid or solid form. Liquid contents must have a specific gravity {lt}2. Solid materials are limited in weight, to include packaging, to the gross weight of the as-tested liquids and bottles.

  17. Closure Strategy for a Waste Disposal Facility with Multiple Waste Types and Regulatory Drivers at the Nevada Test Site

    SciTech Connect (OSTI)

    L. Desotell; D. Wieland; V. Yucel; G. Shott; J. Wrapp

    2008-03-01

    The U.S. Department of Energy, National Security Administration Nevada Site Office (NNSA/NSO) is planning to close the 92-Acre Area of the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada Test Site (NTS), which is about 65 miles northwest of Las Vegas, Nevada. Closure planning for this facility must take into account the regulatory requirements for a diversity of waste streams, disposal and storage configurations, disposal history, and site conditions. This paper provides a brief background of the Area 5 RWMS, identifies key closure issues, and presents the closure strategy. Disposals have been made in 25 shallow excavated pits and trenches and 13 Greater Confinement Disposal (GCD) boreholes at the 92-Acre Area since 1961. The pits and trenches have been used to dispose unclassified low-level waste (LLW), low-level mixed waste (LLMW), and asbestiform waste, and to store classified low-level and low-level mixed materials. The GCD boreholes are intermediate-depth disposal units about 10 feet (ft) in diameter and 120 ft deep. Classified and unclassified high-specific activity LLW, transuranic (TRU), and mixed TRU are disposed in the GCD boreholes. TRU waste was also disposed inadvertently in trench T-04C. Except for three disposal units that are active, all pits and trenches are operationally covered with 8-ft thick alluvium. The 92-Acre Area also includes a Mixed Waste Disposal Unit (MWDU) operating under Resource Conservation and Recovery Act (RCRA) Interim Status, and an asbestiform waste unit operating under a state of Nevada Solid Waste Disposal Site Permit. A single final closure cover is envisioned over the 92-Acre Area. The cover is the evapotranspirative-type cover that has been successfully employed at the NTS. Closure, post-closure care, and monitoring must meet the requirements of the following regulations: U.S. Department of Energy Order 435.1, Title 40 Code of Federal Regulations (CFR) Part 191, Title 40 CFR Part 265, Nevada Administrative Code (NAC) 444.743, RCRA requirements as incorporated into NAC 444.8632, and the Federal Facility Agreement and Consent Order (FFACO). A grouping of waste disposal units according to waste type, location, and similarity in regulatory requirements identified six closure units: LLW Unit, Corrective Action Unit (CAU) 111 under FFACO, Asbestiform LLW Unit, Pit 3 MWDU, TRU GCD Borehole Unit, and TRU Trench Unit. The closure schedule of all units is tied to the closure schedule of the Pit 3 MWDU under RCRA.

  18. Type B Accident Investigation Board Report on the August 5, 1998, Load Haul Dump Accident at U16b Tunnel, Nevada Test Site

    Broader source: Energy.gov [DOE]

    Thisis theType B Accident Investigation Board report of an industrial accident at the Nevada Test site (NTS), U16b tunnel in which a Bechtel Nevada (BN) employee suffered a compressed skull fracture as a result of being struck onthe head by a valve and fitting assembly on the end of a hose whichhad been broken from a water pipe by a moving piece of construction equipment.

  19. Test plan for the M-100 container model M-101/7A/12/90 Docket 96-43-7A, type A container

    SciTech Connect (OSTI)

    Kelly, D.L.

    1997-05-30

    This document describes the test plan for the M-100 Container, Model M-101/7A/12/90. This packaging system is designed to ship Type A solid, radioactive materials, normal form, Form Nos. 1, 2, and 3. The nominal overall dimensions, including risers, of the M-100 Container are 79 x 54 x 42 inches. The capacity of the container is approximately 89.9 ft. The estimated gross weight of the packaging and contents is 9,000 lb.

  20. Responses of Conventional Ring Closures of Drum Type Packages to Regulatory Drop Tests with Application to the 9974/9975 Package

    SciTech Connect (OSTI)

    Blanton, P.S.

    2002-05-31

    DOT, DOE and NRC Type A and Type B radioactive material (RAM) transport packages routinely use industrial or military specification drums with conventional clamp ring closures as an overpack. Considerable testing has been performed on these type packages over the past 30 years. Observations from test data have resulted in various design changes and recommendations to the standard drum specification and use, enhancing the reliability of the overpack. Recently, performance capability of the 9975 conventional clamp ring closure design was questioned by the Regulatory Authority. This paper highlights the observations of recent 9974 and 9975 package testing that led to redesign of the 9975, replacing the standard clamp ring closure with a bolted ring closure. In the course of this review and redesign effort, 18 package designs and approximately 100 Hypothetical Accident Condition (HAC) drops of various size and weight drum packages were evaluated. A trend was observed with respect to overpack lid failures for packages utilizing conventional ring closure. Based on this trend, a limit on the ratio of the content weight to total package weight was identified, beyond which clamp ring closure failure may be expected.

  1. The use of U/sub 3/Si/sub 2/ dispersed in aluminum in plate-type fuel elements for research and test reactors

    SciTech Connect (OSTI)

    Snelgrove, J.L.; Domagala, R.F.; Hofman, G.L.; Wiencek, T.C.; Copeland, G.L.; Hobbs, R.W.; Senn, R.L.

    1987-10-01

    A high-density fuel based on U/sub 3/Si/sub 2/ dispersed in aluminum has been developed and tested for use in converting plate-type research and test reactors from the use of highly enriched uranium to the use of low-enriched uranium. Results of preirradiation testing and the irradiation and postirradiation examination of miniature fuel plates and full-sized fuel elements are summarized. Swelling of the U/sub 3/Si/sub 2/ fuel particles is a linear function of the fission density in the particle to well beyond the fission density achievable in low-enriched fuels. U/sub 3/Si/sub 2/ particle swelling rate is approximately the same as that of the commonly used UAl/sub x/ fuel particle. The presence of minor amounts of U/sub 3/Si or uranium solid solution in the fuel result in greater, but still acceptable, fuel swelling. Blister threshold temperatures are at least as high as those of currently used fuels. An exothermic reaction occurs near the aluminum melting temperature, but the measured energy releases were low enough not to substantially worsen the consequences of an accident. U/sub 3/Si/sub 2/-aluminum dispersion fuel with uranium densities up to at least 4.8 Mg/m/sup 3/ is a suitable LEU fuel for typical plate-type research and test reactors. 42 refs., 28 figs., 7 tabs.

  2. Exploring the effects of a factory-type test-bed on a painted slate defect detection system.

    E-Print Network [OSTI]

    Whelan, Paul F.

    conveyor and operating at production line speeds. Laboratory test bed proven image sensing methods to detect visual defects on painted slates using an automated visual inspection system. The inspection work by a manufacturing environment. We describe the production prototype built to replicate factory conditions including

  3. Test and evaluation report for Lockheed Idaho Technologies Company, arrow-pak packaging, docket 95-40-7A, type A container

    SciTech Connect (OSTI)

    Kelly, D.L.

    1996-03-14

    This report incorporates the U.S. Department of Energy, Office of Facility Safety Analysis (DOE/EH-32) approval letter for packaging use. This report documents the U.S. Department of Transportation Specification 7A Type A (DOT-7A) compliance test results of the Arrow-Pak packaging. The Arrow-Pak packaging system consists of Marlex M-8000 Driscopipe, manufactured by Phillips-Driscopipe, Inc., and is sealed with two dome-shaped end caps manufactured from the same materials. The patented sealing process involves the use of electrical energy to heat opposing faces of the pipe and end caps, and hydraulic rams to press the heated surfaces together. This fusion process produces a homogeneous bonding of the end cap to the pipe. The packaging may be used with or without the two internal plywood spacers. This packaging configuration described in this report is designed to ship Type A quantities of solid radioactive materials.

  4. Apparatus for pre-stress-straining rod-type specimens in tension for in-situ passive fracture testing

    DOE Patents [OSTI]

    Wang, John Jy-an (Oak Ridge, TN); Liu, Ken C. (Oak Ridge, TN); Feng, Zhili (Knoxville, TN)

    2013-07-31

    A stress-strain testing apparatus imposes a stress-strain on a specimen while disposed in a controlled environment. Each end of the specimen is fastened to an end cap and a strain gage is attached to the specimen. An adjusting mechanism and a compression element are disposed between the end caps forming a frame for applying forces to the end caps and thereby stress-straining the specimen. The adjusting mechanism may be extended or retracted to increase or decrease the imposed stress-strain on the specimen, and the stress-strain is measured by the strain gage on the specimen while the apparatus is exposed to an environment such as high pressure hydrogen. Strain gages may be placed on the frame to measure stress-strains in the frame that may be caused by the environment.

  5. Test and evaluation report for Westinghouse Hanford Company`s 1-L Liquid Shipper, Docket 95-41-7A, Type A container

    SciTech Connect (OSTI)

    Kelly, D.L.

    1995-11-01

    This report documents the U.S. Department of Transportation Specification 7A Type A (DOT-7A) compliance test results of the 1-L Liquid Shipper packaging. The 1-L Liquid Shipper consists of the 3M SafeSend polyethylene canister base and cap with integral sorbent material, a quad ring gasket, a plastic bag, and six foam inserts. A 1-L narrow-mouth, Teflon bottle with Tefzel lid holds contents. The inner bottle is placed inside the SafeSend container. The inner bottle content weight cannot exceed 2000 g (4.4 lb). Total bottle weight, including contents cannot exceed 2167.5 g (4.78 lb). The nominal gross weight of the assembled packaging is to be no more that 3830.5 g (8.4 lb). The approved packaging system is designed to ship Type A quantities of radioactive materials, normal form. Contents may be liquid or solid form. Liquid contents may have a specific gravity less than or equal to (<2). Solid materials are limited in weight, to include packaging, to the gross weight of the as-tested liquids and bottles.

  6. Static load cycle testing of a low-aspect-ratio four-inch wall, TRG-type structure, TRG-5-4 (1. 0, 0. 56)

    SciTech Connect (OSTI)

    Farrar, C.R.; Bennett, J.G.; Dunwoody, W.E. (Los Alamos National Lab., NM (USA)); Baker, W.E. (New Mexico Univ., Albuquerque, NM (USA))

    1990-11-01

    This report is the second in a series of test reports that details the quasi-static cyclic testing of low height-to-length aspect ratio reinforced concrete structures. The test structures were designed according to the recommendations of a technical review group for the US Nuclear Regulatory Commission sponsored Seismic Category I Structures Program. The structure tested and reported here had 4-in.-thick shear and end walls, and the elastic deformation was dominated by shear. The background of the program and previous results are given for completeness. Details of the geometry, material property tests, construction history, ultrasonic testing, and modal testing to find the undamaged dynamic characteristics of the structures are given. Next, the static test procedure and results in terms of stiffness and load deformation behavior are given. Finally, results are shown relative to other known results, and conclusions are presented. 33 refs., 140 figs., 13 tabs.

  7. Test Comparability

    E-Print Network [OSTI]

    Keller, Christine; Shulenburger, David E.

    2010-01-01

    stream_size 3106 stream_content_type text/plain stream_name Test Comparability ChangeJuly (2).pdf.txt stream_source_info Test Comparability ChangeJuly (2).pdf.txt Content-Encoding UTF-8 Content-Type text/plain; charset=UTF-8... KU ScholarWorks | http://kuscholarworks.ku.edu Test Comparability 2010 by Christine Keller and David Shulenburger This work has been made available by the University of Kansas Libraries’ Office of Scholarly Communication and Copyright. Please share...

  8. Apparatuses for prestressing rod-type specimens in torsion for in-situ passive fracture toughness testing in an extremely high-pressure environment of hydrogen

    DOE Patents [OSTI]

    Wang, Jy-an (Oak Ridge, TN); Liu, Ken C. (Oak Ridge, TN); Feng, Zhili (Knoxville, TN)

    2012-05-15

    An in-situ specimen fixture particularly adapted for prestressing rod-type SNTT-type specimens comprising a tube and end cap wherein the specimen is secured at one end to the tube, and at the opposite end to the end cap. The end cap is rotatable relative to the tube, and may be fixedly secured for creating a torsional force prestressing the specimen enclosed within the tube.

  9. Test Preparation Options Free Test Prep Websites

    E-Print Network [OSTI]

    Stowell, Michael

    Test Preparation Options Free Test Prep Websites ACT: http: http://www.collegeboard.com/student/testing/sat/prep_one/test.html http://www.number2.com://testprep.princetonreview.com/CourseSearch/Search.aspx?itemCode=17&productType=F&rid=1&zip=803 02 Test Prep Classes Front Range Community College: Classes

  10. Type B Accident Investigation of the Serious Personal Injury while Doble Testing at the Western Area Power Administration Hayden Substation, May 19, 1999

    Broader source: Energy.gov [DOE]

    On May 19, 1999, at 10:31 a.m., four Western Area Power Administration (Western) employees were performing Doble testing on a circuit breaker at Hayden Substation in Routt County, Colorado. Three electricians were injured when the high-voltage lead (HVL) of the Doble test set encroached on the minimum approach distance to an energized part outside clearance boundaries, drawing arcing faults.

  11. Test Automation Test Automation

    E-Print Network [OSTI]

    Mousavi, Mohammad

    Test Automation Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2013 Mousavi: Test Automation #12;Test Automation Outline Test Automation Mousavi: Test Automation #12;Test Automation Why? Challenges of Manual Testing Test-case design: Choosing inputs

  12. TYPE OF OPERATION R Research & Development T& Facility Type

    Office of Legacy Management (LM)

    -- R Research & Development T& Facility Type 0 Production scale testing a Pilat scale Y-. Bench Scale Process i Theoretical Studies Sample & Analysis 0 Productian 0 Disposal...

  13. Plug-In Electric Vehicles' Charging Dr. Alireza Khaligh

    E-Print Network [OSTI]

    Zeng, Ning

    type Price Battery On-Board Charger E-Range Connector type Level 2 Nissan leaf EV $21,300 24kWh LiWh Li-ion 3.3 kW OBC 68 mi SAE J1772 6 hrs Tesla Model S 60kWh EV $71,000 60 kWh Li-ion 10 kW OBC 208 mi battery voltage 320 V ~ 420 V Maximum output power 1 kW Output voltage ripple

  14. Blood Types

    E-Print Network [OSTI]

    Hacker, Randi; Tsutsui, William

    2007-03-14

    Sox spent a hundred mil to acquire pitcher Daisuke Matsuzaka; they probably weren't even aware that he is a Type O and that they make the best bankers, politicians and... you guessed it... professional baseball players. #ceas #hacker #japan #tsutsuien...

  15. GAP TESTS; COMPARISON BETWEEN UN GAP TEST AND CARD GAP TEST

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    98-36 GAP TESTS; COMPARISON BETWEEN UN GAP TEST AND CARD GAP TEST by R. BRANKA and C. MICHOT, FRANCE (tel.: 33 3 44 55 65 19, fax: 33 3 44 55 65 10) ABSTRACT: UN gap test, type 1(a) or 2(a), is the recommended test in the acceptance procedure for transport of explosives in class 1. Up to the revision

  16. Derived Types What Are Derived Types?

    E-Print Network [OSTI]

    Collett Jr., Jeffrey L.

    Derived Types #12;What Are Derived Types? As usual, a hybrid of two, unrelated concepts C++, Python orientation comes in #12;Simple Derived Types TYPE Wheel INTEGER :: spokes REAL :: diameter, width CHARACTER(LEN=15) :: material END TYPE Wheel That defines a derived type Wheel Using derived types needs a special

  17. Derived Types What Are Derived Types?

    E-Print Network [OSTI]

    Collett Jr., Jeffrey L.

    Derived Types #12;What Are Derived Types? As usual, a hybrid of two, unrelated concepts C object orientation comes in This course will only describe the former. #12;Simple Derived Types TYPE That defines a derived type Wheel Using derived types needs a special syntax TYPE(Wheel) :: w1 #12;More

  18. Type: Renewal

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankADVANCEDInstallers/ContractorsPhotovoltaicsStateof Energy TwoEvent at the Pu Facility,Type IV COPV1

  19. Type A Accident Investigation Board Report of the July 28, 1998, Fatality and Multiple Injuries Resulting from Release of Carbon Dioxide at Building 648, Test Reactor Area, Idaho National Engineering and Environmental Laboratory

    Broader source: Energy.gov [DOE]

    This report is an independent product of the Type A Accident Investigation Board appointed by Peter N. Brush, Acting Assistant Secretary for Environment, Safety and Health (EH-1).

  20. Fuel Tank Manufacturing, Testing, Field Performance, and Certification...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Documents & Publications Tank Manufacturing, Testing, Deployment and Field Performance CNG and Hydrogen Tank Safety, R&D, and Testing Type 4 Tank Testing, Certification and Field...

  1. MATERIAL TESTING OF LIQUID METAL

    E-Print Network [OSTI]

    Huang, Wei

    with the development and improvement of renewable energy technology. On a more personal note, he enjoys most shades vacuum chamber at NASA Langley Research Center. Two types of LMSGs were tested: indium-gallium and mercury. Testing showed that both types were functional after being subjected to extreme vacuum

  2. STUDY TYPES What is a "Study Type"?

    E-Print Network [OSTI]

    Dorf, Martin E.

    #12;STUDY TYPES What is a "Study Type"? A Study Type is a defined business process. Study Types work together to streamline workflow, track data & keep users informed. There are 2 Study Types in eCOMS: COMS and IACUC. The COMS Study: The COMS Study is an online form that a Principal Investigator fills

  3. Software Robustness Testing A Ballista Retrospective

    E-Print Network [OSTI]

    Koopman, Philip

    Software Robustness Testing A Ballista Retrospective Phil Koopman koopman@cmu.edu http://ballista & training #12;3 Ballista Software Testing Overview Abstracts testing to the API/Data type level · Most test UNDER TEST ROBUST OPERATION REPRODUCIBLE FAILURE UNREPRODUCIBLE FAILURE #12;4 Ballista: Test Generation

  4. Assignment Types UTS LIBRARY

    E-Print Network [OSTI]

    University of Technology, Sydney

    Assignment Types UTS LIBRARY February 2013 Academic Writing Guide Part 2 ­ Assignment Types: This section outlines the basic types of written assignments, providing structural elements and examples. #12;2 II. Assignment Types 1. Essay Writing

  5. A Typed Operational Semantics for Type Theory 

    E-Print Network [OSTI]

    Goguen, Healfdene

    Untyped reduction provides a natural operational semantics for type theory. Normalization results say that such a semantics is sound. However, this reduction does not take type information into account and gives no information ...

  6. Testing of the structural evaluation test unit

    SciTech Connect (OSTI)

    Ammerman, D.J.; Bobbe, J.G.

    1995-12-31

    In the evaluation of the safety of radioactive material transportation it is important to consider the response of Type B packages to environments more severe than that prescribed by the hypothetical accident sequence in Title 10 Part 71 of the Code of Federal Regulations (NRC 1995). The impact event in this sequence is a 9-meter drop onto an essentially unyielding target, resulting in an impact velocity of 13.4 m/s. The behavior of 9 packages when subjected to impacts more severe than this is not well known. It is the purpose of this program to evaluate the structural response of a test package to these environments. Several types of structural response are considered. Of primary importance is the behavior of the package containment boundary, including the bolted closure and 0-rings. Other areas of concern are loss of shielding capability due to lead slump and the deceleration loading of package contents, that may cause damage to them. This type of information is essential for conducting accurate risk assessments on the transportation of radioactive materials. Currently very conservative estimates of the loss of package protection are used in these assessments. This paper will summarize the results of a regulatory impact test and three extra-regulatory impact tests on a sample package.

  7. Test Images

    E-Print Network [OSTI]

    Test Images. I hope to have a set of test images for the course soon. Some images are available now; some will have to wait until I can find another 100-200

  8. Meatiness Testing 

    E-Print Network [OSTI]

    Unknown

    2011-08-17

    The purpose of this research was to investigate the ignition phenomena of selected polymeric materials using the Hot Wire Ignition Test. This test is prescribed by Underwriters Laboratories as one of various requirements ...

  9. Verification Testing Test Driven Development Testing with JUnit Verification

    E-Print Network [OSTI]

    Peters, Dennis

    Verification Testing Test Driven Development Testing with JUnit Verification Any activity should be verified. #12;Verification Testing Test Driven Development Testing with JUnit Approaches to verification 1 Testing 2 Static Analysis · Peer review · Insepction/Walk-through/Structured review · Formal

  10. Types of Commissioning

    Broader source: Energy.gov [DOE]

    Several commissioning types exist to address the specific needs of equipment and systems across both new and existing buildings. The following commissioning types provide a good overview.

  11. Postdoc Appointment Types

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Appointment Types Postdoc Appointment Types Most postdocs will be offered a postdoctoral research associate appointment. Each year, approximately 30 Postdoctoral Fellow...

  12. Types of Lights Types of Lights

    E-Print Network [OSTI]

    1 Types of Lights Types of Lights q So far we have studied point lights ­ Radiate in all direc7ons q Other lights ­ Direc7onal lights (posi7on-independent) ­ Spotlights #12;2 Direc1onal Lights q Shine in a single, uniform direc7on q All rays

  13. Testing for PV Reliability (Presentation)

    SciTech Connect (OSTI)

    Kurtz, S.; Bansal, S.

    2014-09-01

    The DOE SUNSHOT workshop is seeking input from the community about PV reliability and how the DOE might address gaps in understanding. This presentation describes the types of testing that are needed for PV reliability and introduces a discussion to identify gaps in our understanding of PV reliability testing.

  14. Type B Accident Investigation Board Report on the October 15...

    Energy Savers [EERE]

    15, 2001, Grout Injection Operator Injury at the Cold Test Pit South, Idaho National Engineering and Environmental Laboratory Type B Accident Investigation Board Report on the...

  15. Type B Accident Investigation Board Report on the October 15...

    Office of Environmental Management (EM)

    Type B Accident Investigation Board Report on the October 15, 2001, Grout Injection Operator Injury at the Cold Test Pit South, Idaho National Engineering and Environmental...

  16. Types of Reuse

    Broader source: Energy.gov [DOE]

    The following provides greater detail regarding the types of reuse pursued for LM sites. It should be noted that many actual reuses combine several types of the uses listed below.

  17. Analysis of Senate Bill 1245: Cervical Cancer Screening Test

    E-Print Network [OSTI]

    California Health Benefits Review Program (CHBRP)

    2006-01-01

    Pap=Papanicolaou (Pap) test Table B-1b. Triage Studies Name,of the human papillomavirus test and Papanicolaou smear as aManagement of women who test positive for high-risk types of

  18. Test Automation Ant JUnit Test Automation

    E-Print Network [OSTI]

    Mousavi, Mohammad

    Test Automation Ant JUnit Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2012 Mousavi: Test Automation #12;Test Automation Ant JUnit Outline Test Automation Ant JUnit Mousavi: Test Automation #12;Test Automation Ant JUnit Why? Challenges of Manual Testing

  19. Diesel Engine Idling Test

    SciTech Connect (OSTI)

    Larry Zirker; James Francfort; Jordon Fielding

    2006-02-01

    In support of the Department of Energy’s FreedomCAR and Vehicle Technology Program Office goal to minimize diesel engine idling and reduce the consumption of millions of gallons of diesel fuel consumed during heavy vehicle idling periods, the Idaho National Laboratory (INL) conducted tests to characterize diesel engine wear rates caused by extended periods of idling. INL idled two fleet buses equipped with Detroit Diesel Series 50 engines, each for 1,000 hours. Engine wear metals were characterized from weekly oil analysis samples and destructive filter analyses. Full-flow and the bypass filter cartridges were removed at four stages of the testing and sent to an oil analysis laboratory for destructive analysis to ascertain the metals captured in the filters and to establish wear rate trends. Weekly samples were sent to two independent oil analysis laboratories. Concurrent with the filter analysis, a comprehensive array of other laboratory tests ascertained the condition of the oil, wear particle types, and ferrous particles. Extensive ferrogram testing physically showed the concentration of iron particles and associated debris in the oil. The tests results did not show the dramatic results anticipated but did show wear trends. New West Technologies, LLC, a DOE support company, supplied technical support and data analysis throughout the idle test.

  20. Modal test optimization using VETO (Virtual Environment for Test Optimization)

    SciTech Connect (OSTI)

    Klenke, S.E.; Reese, G.M.; Schoof, L.A.; Shierling, C.

    1996-01-01

    We present a software environment integrating analysis and test-based models to support optimal modal test design through a Virtual Environment for Test Optimization (VETO). A goal in developing this software tool is to provide test and analysis organizations with a capability of mathematically simulating the complete test environment in software. Derived models of test equipment, instrumentation and hardware can be combined within the VETO to provide the user with a unique analysis and visualization capability to evaluate new and existing test methods. The VETO assists analysis and test engineers in maximizing the value of each modal test. It is particularly advantageous for structural dynamics model reconciliation applications. The VETO enables an engineer to interact with a finite element model of a test object to optimally place sensors and exciters and to investigate the selection of data acquisition parameters needed to conduct a complete modal survey. Additionally, the user can evaluate the use of different types of instrumentation such as filters, amplifiers and transducers for which models are available in the VETO. The dynamic response of most of the virtual instruments (including the device under test) is modeled in the state space domain. Design of modal excitation levels and appropriate test instrumentation are facilitated by the VETO`s ability to simulate such features as unmeasured external inputs, A/D quantization effects, and electronic noise. Measures of the quality of the experimental design, including the Modal Assurance Criterion, and the Normal Mode Indicator Function are available.

  1. TYPES OF NONIMMIGRANT VISAS Type Description

    E-Print Network [OSTI]

    for pleasure and cannot receive any type of payments. C-1*, Aliens in travel status while travelling directly through the C-2*, United States. C-3* D-1 Alien crewman on shore leave or transferring to another vessel is grounds for deportation. E-1 Aliens who conduct trade or inventories between the United States

  2. F-type Tests for Linear Models with Functional Responses

    E-Print Network [OSTI]

    Zhang, Jin-Ting

    ), Ergonomics data (Faraway 1997), and Children growth curves (Zhang, Liang and Xiao 2010) among others-reduction involved. Drawback: may lose of some power 5 #12;' & $ % Introduction Motivating Example: the Ergonomics The Ergonomics Data 0 0.2 0.4 0.6 0.8 1 120 140 160 180 Curve 1 0 0.2 0.4 0.6 0.8 1 120 130 140 150 160 Curve 6 0

  3. Type 4 Tank Testing, Certification and Field Performance Data

    Broader source: Energy.gov [DOE]

    These slides were presented at the International Hydrogen Fuel and Pressure Vessel Forum on September 27 – 29, 2010, in Beijing, China.

  4. Property:Hydrodynamic Testing Facility Type | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmental Jump to: navigation,PropertyPartner7Website JumpHeatSource Jump

  5. Category:Hydrodynamic Testing Facility Type | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmentalBowerbank,CammackFLIR Jump to: navigation,Ground Gravity Survey Jump to:Help Jump

  6. Verifying Test Hypotheses -HOL/TestGen Verifying Test Hypotheses -HOL/TestGen

    E-Print Network [OSTI]

    Verifying Test Hypotheses - HOL/TestGen Verifying Test Hypotheses - HOL/TestGen An Experiment in Test and Proof Thomas Malcher January 20, 2014 1 / 20 #12;Verifying Test Hypotheses - HOL/TestGen HOL/TestGen Outline Introduction Test Hypotheses HOL/TestGen - Demo Verifying Test Hypotheses Conclusion 2 / 20 #12

  7. Typed Self-Optimization

    E-Print Network [OSTI]

    Brown, Matt

    2013-01-01

    type T y[O]. The operator IsIs is self-applicative, in thatargument t is any of Is[O] or IsIs, and otherwise behavesproof constant introduced by IsIs proves that the type of t

  8. Good Test Cases Copyright Cem Kaner 2003. All rights reserved. Page 1 What Is a Good Test Case?

    E-Print Network [OSTI]

    Good Test Cases Copyright © Cem Kaner 2003. All rights reserved. Page 1 What Is a Good Test Case of the National Science Foundation (NSF). Abstract Designing good test cases is a complex art. The complexity comes from three sources: Test cases help us discover information. Different types of tests are more

  9. Hybrid type checking

    E-Print Network [OSTI]

    Flanagan, C

    2006-01-01

    O’Callahan and J. -D. Choi. Hybrid dynamic data race detec-subtyping is sound, the hybrid compilation algorithmHybrid Type Checking Cormac Flanagan Department of Computer

  10. Fejer-type inequalities

    E-Print Network [OSTI]

    Mitroi, F C

    2011-01-01

    The aim of this paper is to present some new Fejer-type results for convex functions. Improvements of Young's inequality (the arithmetic-geometric mean inequality) and other applications to special means are pointed as well.

  11. Prototype to Test WHY prototype to test

    E-Print Network [OSTI]

    Prinz, Friedrich B.

    Prototype to Test METHOD WHY prototype to test HOW to prototype to test Prototyping to test or design space. The fundamental way you test your prototypes is by letting users experience them and react to them. In creating prototypes to test with users you have the opportunity to examine your solution

  12. Testing with JUnit Testing with JUnit

    E-Print Network [OSTI]

    Peters, Dennis

    Testing with JUnit Testing with JUnit Running a test case: 1 Get the component to a known state (set up). 2 Cause some event (the test case). 3 Check the behaviour. · Record pass/fail · Track statistics · Typically we want to do a lot of test cases so it makes sense to automate. · Test cases

  13. A Systematic Method for Modifying March Tests for Bit-Oriented Memories into Tests

    E-Print Network [OSTI]

    application. The tests for WOMs to detect coupling faults (CFs) [2], [3], [1] used different types of DBs for intraword CFs. This paper presents an improved, systematic method to convert march tests for BOMs into march introduced tests for intraword CFs and describes the influence the memory organization has on the to

  14. Pressure Change Measurement Leak Testing Errors

    SciTech Connect (OSTI)

    Pryor, Jeff M; Walker, William C

    2014-01-01

    A pressure change test is a common leak testing method used in construction and Non-Destructive Examination (NDE). The test is known as being a fast, simple, and easy to apply evaluation method. While this method may be fairly quick to conduct and require simple instrumentation, the engineering behind this type of test is more complex than is apparent on the surface. This paper intends to discuss some of the more common errors made during the application of a pressure change test and give the test engineer insight into how to correctly compensate for these factors. The principals discussed here apply to ideal gases such as air or other monoatomic or diatomic gasses; however these same principals can be applied to polyatomic gasses or liquid flow rate with altered formula specific to those types of tests using the same methodology.

  15. Notice Type: Presolicitation

    E-Print Network [OSTI]

    -- Computer and Electronic Product Manufacturing/334515 -- Instrument Manufacturing for Measuring and Testing Polarization P/N: WS-AA-2000S-ZZ-H. (Microsoft IE required). Additional specifications and opening and closing

  16. Type Ia Supernovae

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired SolarAbout /Two Electron Holes in HematiteType Ia Supernovae Type Ia

  17. Agreement Type Union

    National Nuclear Security Administration (NNSA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefield Municipal Gas &SCE-SessionsSouthReporteeo | National Nucleara min [Type the abstract of theType

  18. Orion Flight Test Exploration Flight Test-1

    E-Print Network [OSTI]

    Rathbun, Julie A.

    Orion Flight Test Exploration Flight Test-1 PRESS KIT/December 2014 www.nasa.gov NP-2014-11-020-JSC National Aeronautics and Space Administration #12;#12;Orion Flight Test December 2014 Contents Section Page ........................................................................................... 28 i #12;Orion Flight Test ii December 2014 #12;Orion Flight Test December 2014 Flight Overview

  19. Test and Test Equipment Joshua Lottich

    E-Print Network [OSTI]

    Patel, Chintan

    Test and Test Equipment Joshua Lottich CMPE 640 11/23/05 #12;Testing Verifies that manufactured chip meets design specifications. Cannot test for every potential defect. Modeling defects as faults allows for passing and failing of chips. Ideal test would capture all defects and pass only chips

  20. Basics, types Evolution

    E-Print Network [OSTI]

    Crenshaw, Michael

    to nuclear fusion. · Novae radiate primarily in the UV to X-ray region. · Types: ­ Classical Novae: only one is hot enough for explosive fusion. For classical novae, this happens on a time scale of 103 ­ 105 years. · Thermonuclear runaway (TNR): capture of protons by heavy elements (CNO cycle), happens in seconds #12;5 Novae

  1. Propagation testing multi-cell batteries.

    SciTech Connect (OSTI)

    Orendorff, Christopher J.; Lamb, Joshua; Steele, Leigh Anna Marie; Spangler, Scott Wilmer

    2014-10-01

    Propagation of single point or single cell failures in multi-cell batteries is a significant concern as batteries increase in scale for a variety of civilian and military applications. This report describes the procedure for testing failure propagation along with some representative test results to highlight the potential outcomes for different battery types and designs.

  2. Test plan/procedure for the SPM-1 shipping container system. Revision 0

    SciTech Connect (OSTI)

    Flanagan, B.D.

    1995-07-01

    The 49 CFR 173.465 Type A packaging tests will verify that SPM-1 will provide adequate protection and pass as a Type A package. Test will determine that the handle of the Pig will not penetrate through the plywood spacer and rupture the shipping container. Test plan/procedure provides planning, pre-test, setup, testing, and post-testing guidelines and procedures for conducting the {open_quotes}Free Drop Test{close_quotes} procedure for the SPM-1 package.

  3. DOT-7A packaging test procedure

    SciTech Connect (OSTI)

    Kelly, D.L.

    1995-01-23

    This test procedure documents the steps involved with performance testing of Department of Transportation Specification 7A (DOT-7A) Type A packages. It includes description of the performance tests, the personnel involved, appropriate safety considerations, and the procedures to be followed while performing the tests. Westinghouse Hanford Company (WHC) is conducting the evaluation and testing discussed herein for the Department of Energy-Headquarters, Division of Quality Verification and Transportation Safety (EH-321). Please note that this report is not in WHC format. This report is being submitted through the Engineering Documentation System so that it may be used for reference and information purposes.

  4. Energy.gov Page Types

    Broader source: Energy.gov [DOE]

    Learn about the standard page types available in the Energy.gov Drupal content management system. For information about other available page types, or to request a new kind of page type, contact...

  5. Practical pluggable types for Java

    E-Print Network [OSTI]

    Papi, Matthew M

    2008-01-01

    This paper introduces the Checker Framework, which supports adding pluggable type systems to the Java language in a backward-compatible way. A type system designer defines type qualifiers and their semantics, and a compiler ...

  6. Window Types | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    aluminum or vinyl cladding reduces maintenance requirements. Types of Window Glazing or Glass In addition to choosing a frame type, you will need to consider what type of glazing...

  7. Intro Temporal Tests Declustering Methods Tests on SCEC data Spatiotemporal Test Discussion Testing for Poisson Behavior

    E-Print Network [OSTI]

    Stark, Philip B.

    Intro Temporal Tests Declustering Methods Tests on SCEC data Spatiotemporal Test Discussion Testing Seismological Society of America Annual Meeting San Diego, CA #12;Intro Temporal Tests Declustering Methods Tests on SCEC data Spatiotemporal Test Discussion Quake Physics versus Quake Statistics · Distribution

  8. Paired t testsPaired t tests Paired (dependent) t-testPaired (dependent) t test

    E-Print Network [OSTI]

    Wolverton, Steve

    Paired t testsPaired t tests #12;Paired (dependent) t-testPaired (dependent) t test · Compares test means from matched pairsCompares test means from matched pairs or two different samples from the same individualsindividuals ­ e.g., pretest & post test scores for the same group of students Ho: d = 0 d is thedifference

  9. Dust around Type Ia supernovae

    E-Print Network [OSTI]

    Wang, Lifan

    2005-01-01

    Dust around Type Ia supernovae Lifan Wang 1,2 LawrenceIa. Subject headings: Supernovae: General, Dust, Extinctionline) bands for Type Ia supernovae. (a), upper panel, shows

  10. CNP_TEST_SUITE

    Energy Science and Technology Software Center (OSTI)

    002854MLTPL00 Automated Nuclear Data Test Suite  file:///usr/gapps/CNP_src/us/RR/test_suite_cz/cnp_test_suite 

  11. Reactor Material Program Fracture Toughness of Type 304 Stainless Steel

    SciTech Connect (OSTI)

    Awadalla, N.G.

    2001-03-28

    This report describes the experimental procedure for Type 304 Stainless Steel fracture toughness measurements and the application of results. Typical toughness values are given based on the completed test program for the Reactor Materials Program (RMP). Test specimen size effects and limitations of the applicability in the fracture mechanics methodology are outlined as well as a brief discussion on irradiation effects.

  12. CMVO Drug Testing Program Reasonable Suspicion Testing

    E-Print Network [OSTI]

    Sin, Peter

    CMVO Drug Testing Program Reasonable Suspicion Testing CMVO Revised Suspicion Form (Revised 6/08) Guidelines for Reasonable Suspicion Drug and Alcohol Testing: A supervisor, trained in accordance with 49 CFR involved in an incident that requires drug/alcohol testing as set forth in 382.307. Remember: Reasonable

  13. TEST STATION SALE OF PERFORMANCE TESTED BULLS

    E-Print Network [OSTI]

    Tennessee, University of

    in the test had to meet minimum performance requirements. Those were: CREEP NON-CREEP Adj 205 day wt. 560 520AS-B428 U T BULL TEST STATION SALE OF PERFORMANCE TESTED BULLS THURSDAY, MARCH 8, 2012 12:00 NOON IN GREENEVILLE AND KNOXVILLE LIVESTOCK CENTER http://animalscience.ag.utk.edu/ (For video) #12;UT BULL TEST

  14. Bull Test ID 1181 2013 Florida Bull Test

    E-Print Network [OSTI]

    Jawitz, James W.

    Bull Test ID 1181 2013 Florida Bull Test #12;Bull Test ID 1182 2013 Florida Bull Test #12;Bull Test ID 1183 2013 Florida Bull Test #12;Bull Test ID 1184 2013 Florida Bull Test #12;Bull Test ID 1185 2013 Florida Bull Test #12;Bull Test ID 1186 2013 Florida Bull Test #12;Bull Test ID 1187 2013 Florida

  15. Bull Test ID 1140 2013 Florida Bull Test

    E-Print Network [OSTI]

    Jawitz, James W.

    Bull Test ID 1140 2013 Florida Bull Test #12;Bull Test ID 1141 2013 Florida Bull Test #12;Bull Test ID 1142 2013 Florida Bull Test #12;Bull Test ID 1143 2013 Florida Bull Test #12;Bull Test ID 1144 2013 Florida Bull Test #12;Bull Test ID 1145 2013 Florida Bull Test #12;Bull Test ID 1146 2013 Florida

  16. Bull Test ID 1077 2013 Florida Bull Test

    E-Print Network [OSTI]

    Jawitz, James W.

    14th Annual Florida Bull Test #12;Bull Test ID 1077 2013 Florida Bull Test #12;Bull Test ID 1078 2013 Florida Bull Test #12;Bull Test ID 1079 2013 Florida Bull Test #12;Bull Test ID 1080 2013 Florida Bull Test #12;Bull Test ID 1081 2013 Florida Bull Test #12;Bull Test ID 1082 2013 Florida Bull Test #12

  17. Bull Test ID 1098 2013 Florida Bull Test

    E-Print Network [OSTI]

    Jawitz, James W.

    Bull Test ID 1098 2013 Florida Bull Test #12;Bull Test ID 1099 2013 Florida Bull Test #12;Bull Test ID 1100 2013 Florida Bull Test #12;Bull Test ID 1101 2013 Florida Bull Test #12;Bull Test ID 1102 2013 Florida Bull Test #12;Bull Test ID 1103 2013 Florida Bull Test #12;Bull Test ID 1104 2013 Florida

  18. Bull Test ID 1118 2013 Florida Bull Test

    E-Print Network [OSTI]

    Jawitz, James W.

    Bull Test ID 1118 2013 Florida Bull Test #12;Bull Test ID 1119 2013 Florida Bull Test #12;Bull Test ID 1120 2013 Florida Bull Test #12;Bull Test ID 1121 2013 Florida Bull Test #12;Bull Test ID 1122 2013 Florida Bull Test #12;Bull Test ID 1123 2013 Florida Bull Test #12;Bull Test ID 1124 2013 Florida

  19. Bull Test ID 1160 2013 Florida Bull Test

    E-Print Network [OSTI]

    Jawitz, James W.

    Bull Test ID 1160 2013 Florida Bull Test #12;Bull Test ID 1161 2013 Florida Bull Test #12;Bull Test ID 1162 2013 Florida Bull Test #12;Bull Test ID 1163 2013 Florida Bull Test #12;Bull Test ID 1164 2013 Florida Bull Test #12;Bull Test ID 1165 2013 Florida Bull Test #12;Bull Test ID 1166 2013 Florida

  20. Unit Testing Discussion C

    E-Print Network [OSTI]

    Massachusetts at Amherst, University of

    Unit Testing Discussion C #12;Unit Test public Method is smallest unit of code Input/output transformation Test if the method does what it claims Not exactly black box testing #12;Test if (actual result Expected Computed Input #12;Functionality Computation ­ Easy to test Time based Asynchronous interaction

  1. Pluggable type-checking for custom type qualifiers in Java

    E-Print Network [OSTI]

    Papi, Matthew M.

    2007-09-17

    We have created a framework for adding custom type qualifiers to the Javalanguage in a backward-compatible way. The type system designer definesthe qualifiers and creates a compiler plug-in that enforces theirsemantics. ...

  2. PICTURE GROUPS OF FINITE TYPE AND COHOMOLOGY IN TYPE An

    E-Print Network [OSTI]

    Igusa, Kiyoshi

    PICTURE GROUPS OF FINITE TYPE AND COHOMOLOGY IN TYPE An KIYOSHI IGUSA, KENT ORR, GORDANA TODOROV a picture group. We construct a finite CW complex which is shown in another paper [10] to be a K(, 1) for this picture group. In [5] another independent proof was given for this fact in the special case of type

  3. Abstract Data Types 5 Algebraic Theory of Abstract Data Types

    E-Print Network [OSTI]

    Berger, Ulrich

    stack top: stack elts The following is an algebra for the signature STACK. Algebra SeqN Carriers N, N43 Part II Abstract Data Types #12;44 5 Algebraic Theory of Abstract Data Types An Abstract Data Type (ADT) is a collection of objects and functions, that is, an algebra, where one ignores how

  4. Pittsburg: Immune Myopathy Testing Tests performed

    E-Print Network [OSTI]

    Baloh, Bob

    . Packaging will include a sealed watertight primary vessel as well as a watertight secondary vesselPittsburg: Immune Myopathy Testing Tests performed Myositis associated antibodies: Jo-1; PL-12; PL for autoantibody testing. For adults: please draw two 10 ml red top or serum separator tubes. For children

  5. Tornado type wind turbines

    DOE Patents [OSTI]

    Hsu, Cheng-Ting (Ames, IA)

    1984-01-01

    A tornado type wind turbine has a vertically disposed wind collecting tower with spaced apart inner and outer walls and a central bore. The upper end of the tower is open while the lower end of the structure is in communication with a wind intake chamber. An opening in the wind chamber is positioned over a turbine which is in driving communication with an electrical generator. An opening between the inner and outer walls at the lower end of the tower permits radially flowing air to enter the space between the inner and outer walls while a vertically disposed opening in the wind collecting tower permits tangentially flowing air to enter the central bore. A porous portion of the inner wall permits the radially flowing air to interact with the tangentially flowing air so as to create an intensified vortex flow which exits out of the top opening of the tower so as to create a low pressure core and thus draw air through the opening of the wind intake chamber so as to drive the turbine.

  6. Annotated Type Systems Program Analysis

    E-Print Network [OSTI]

    Palsberg, Jens

    Danish Summary xi 1 Introduction 1 1.1 The Standard Type System . . . . . . . . . . . . . . . . . 3 1 . . . . . . . . . . . . . . . . . . 36 2.1.3 The Conjunction Type System . . . . . . . . . . . . 37 2.2 The Power of tAnnotated Type Systems for Program Analysis Kirsten Lackner Solberg Computer Science Department

  7. PROGRAMMING WITH TYPES A Dissertation

    E-Print Network [OSTI]

    Weirich, Stephanie

    WITH TYPES Stephanie Claudene Weirich, Ph.D. Cornell University 2002 Run-time type analysis, facilities to support type analysis often require complicated language semantics that allow little freedom to list. Steve's parents Arthur and Deborah Zdancewic have encouraged me as long as I have known them. I

  8. Integrated Recycling Test Fuel Fabrication

    SciTech Connect (OSTI)

    R.S. Fielding; K.H. Kim; B. Grover; J. Smith; J. King; K. Wendt; D. Chapman; L. Zirker

    2013-03-01

    The Integrated Recycling Test is a collaborative irradiation test that will electrochemically recycle used light water reactor fuel into metallic fuel feedstock. The feedstock will be fabricated into a metallic fast reactor type fuel that will be irradiation tested in a drop in capsule test in the Advanced Test Reactor on the Idaho National Laboratory site. This paper will summarize the fuel fabrication activities and design efforts. Casting development will include developing a casting process and system. The closure welding system will be based on the gas tungsten arc burst welding process. The settler/bonder system has been designed to be a simple system which provides heating and controllable impact energy to ensure wetting between the fuel and cladding. The final major pieces of equipment to be designed are the weld and sodium bond inspection system. Both x-radiography and ultrasonic inspection techniques have been examine experimentally and found to be feasible, however the final remote system has not been designed. Conceptual designs for radiography and an ultrasonic system have been made.

  9. ZiaTest

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ZiaTest ZiaTest Description This test executes a new proposed standard benchmark method for MPI startup that is intended to provide a realistic assessment of both launch and wireup...

  10. Major Partner Test Sites

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Major Test Partners Once a technology is ready to be tested at pilot or commercial scale, the cost of building a test facility becomes significant -- often beyond the funding...

  11. Directed random testing

    E-Print Network [OSTI]

    Pacheco, Carlos, Ph.D. Massachusetts Institute of Technology

    2009-01-01

    Random testing can quickly generate many tests, is easy to implement, scales to large software applications, and reveals software errors. But it tends to generate many tests that are illegal or that exercise the same parts ...

  12. Sandia Energy - Experimental Testing

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Experimental Testing Home Stationary Power Nuclear Fuel Cycle Nuclear Energy Safety Technologies Experimental Testing Experimental TestingTara Camacho-Lopez2015-05-11T18:46:46+00:0...

  13. Sandia Energy - Mechanical Testing

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Mechanical Testing Home Stationary Power Nuclear Fuel Cycle Advanced Nuclear Energy Nuclear Energy Systems Laboratory (NESL) Brayton Lab Mechanical Testing Mechanical...

  14. Vendor System Vulnerability Testing Test Plan

    SciTech Connect (OSTI)

    James R. Davidson

    2005-01-01

    The Idaho National Laboratory (INL) prepared this generic test plan to provide clients (vendors, end users, program sponsors, etc.) with a sense of the scope and depth of vulnerability testing performed at the INL’s Supervisory Control and Data Acquisition (SCADA) Test Bed and to serve as an example of such a plan. Although this test plan specifically addresses vulnerability testing of systems applied to the energy sector (electric/power transmission and distribution and oil and gas systems), it is generic enough to be applied to control systems used in other critical infrastructures such as the transportation sector, water/waste water sector, or hazardous chemical production facilities. The SCADA Test Bed is established at the INL as a testing environment to evaluate the security vulnerabilities of SCADA systems, energy management systems (EMS), and distributed control systems. It now supports multiple programs sponsored by the U.S. Department of Energy, the U.S. Department of Homeland Security, other government agencies, and private sector clients. This particular test plan applies to testing conducted on a SCADA/EMS provided by a vendor. Before performing detailed vulnerability testing of a SCADA/EMS, an as delivered baseline examination of the system is conducted, to establish a starting point for all-subsequent testing. The series of baseline tests document factory delivered defaults, system configuration, and potential configuration changes to aid in the development of a security plan for in depth vulnerability testing. The baseline test document is provided to the System Provider,a who evaluates the baseline report and provides recommendations to the system configuration to enhance the security profile of the baseline system. Vulnerability testing is then conducted at the SCADA Test Bed, which provides an in-depth security analysis of the Vendor’s system.b a. The term System Provider replaces the name of the company/organization providing the system being evaluated. This can be the system manufacturer, a system user, or a third party organization such as a government agency. b. The term Vendor (or Vendor’s) System replaces the name of the specific SCADA/EMS being tested.

  15. University of Alberta SafeType: Detecting Type Violations for Type-Based Alias

    E-Print Network [OSTI]

    Amaral, José Nelson

    University of Alberta SafeType: Detecting Type Violations for Type-Based Alias Analysis of C Edmonton, Alberta Permission is hereby granted to the University of Alberta Libraries to reproduce single, the University of Alberta will advise potential users of the thesis of these terms. The author reserves all other

  16. FUEL ASSEMBLY SHAKER TEST SIMULATION

    SciTech Connect (OSTI)

    Klymyshyn, Nicholas A.; Sanborn, Scott E.; Adkins, Harold E.; Hanson, Brady D.

    2013-05-30

    This report describes the modeling of a PWR fuel assembly under dynamic shock loading in support of the Sandia National Laboratories (SNL) shaker test campaign. The focus of the test campaign is on evaluating the response of used fuel to shock and vibration loads that a can occur during highway transport. Modeling began in 2012 using an LS-DYNA fuel assembly model that was first created for modeling impact scenarios. SNL’s proposed test scenario was simulated through analysis and the calculated results helped guide the instrumentation and other aspects of the testing. During FY 2013, the fuel assembly model was refined to better represent the test surrogate. Analysis of the proposed loads suggested the frequency band needed to be lowered to attempt to excite the lower natural frequencies of the fuel assembly. Despite SNL’s expansion of lower frequency components in their five shock realizations, pretest predictions suggested a very mild dynamic response to the test loading. After testing was completed, one specific shock case was modeled, using recorded accelerometer data to excite the model. Direct comparison of predicted strain in the cladding was made to the recorded strain gauge data. The magnitude of both sets of strain (calculated and recorded) are very low, compared to the expected yield strength of the Zircaloy-4 material. The model was accurate enough to predict that no yielding of the cladding was expected, but its precision at predicting micro strains is questionable. The SNL test data offers some opportunity for validation of the finite element model, but the specific loading conditions of the testing only excite the fuel assembly to respond in a limited manner. For example, the test accelerations were not strong enough to substantially drive the fuel assembly out of contact with the basket. Under this test scenario, the fuel assembly model does a reasonable job of approximating actual fuel assembly response, a claim that can be verified through direct comparison of model results to recorded test results. This does not offer validation for the fuel assembly model in all conceivable cases, such as high kinetic energy shock cases where the fuel assembly might lift off the basket floor to strike to basket ceiling. This type of nonlinear behavior was not witnessed in testing, so the model does not have test data to be validated against.a basis for validation in cases that substantially alter the fuel assembly response range. This leads to a gap in knowledge that is identified through this modeling study. The SNL shaker testing loaded a surrogate fuel assembly with a certain set of artificially-generated time histories. One thing all the shock cases had in common was an elimination of low frequency components, which reduces the rigid body dynamic response of the system. It is not known if the SNL test cases effectively bound all highway transportation scenarios, or if significantly greater rigid body motion than was tested is credible. This knowledge gap could be filled through modeling the vehicle dynamics of a used fuel conveyance, or by collecting acceleration time history data from an actual conveyance under highway conditions.

  17. ZEST flight test experiments, Kauai Test Facility, Hawaii. Test report

    SciTech Connect (OSTI)

    Cenkci, M.J.

    1991-07-01

    The Strategic Defense Initiative Organization (SDIO) is proposing to execute two ZEST flight experiments to obtain information related to the following objectives: validation of payload modeling; characterization of a high energy release cloud; and documentation of scientific phenomena that may occur as a result of releasing a high energy cloud. The proposed action is to design, develop, launch, and detonate two payloads carrying high energy explosives. Activities required to support this proposal include: (1) execution of component assembly tests at Space Data Division (SDD) in Chandler, Arizona and Los Alamos National Laboratory (LANL) in Los Alamos, New Mexico, and (2) execution of pre-flight flight test activities at Kauai Test Facility.

  18. Accelerated Stress Testing, Qualification Testing, HAST, Field...

    Office of Environmental Management (EM)

    Testing, HAST, Field Experience This presentation, which was the opening session of the NREL 2013 Photovoltaic Module Reliability Workshop held on February 26, 2013 in Golden, CO,...

  19. Standard test method for creep-fatigue crack growth testing

    E-Print Network [OSTI]

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of creep-fatigue crack growth properties of nominally homogeneous materials by use of pre-cracked compact type, C(T), test specimens subjected to uniaxial cyclic forces. It concerns fatigue cycling with sufficiently long loading/unloading rates or hold-times, or both, to cause creep deformation at the crack tip and the creep deformation be responsible for enhanced crack growth per loading cycle. It is intended as a guide for creep-fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. Therefore, this method requires testing of at least two specimens that yield overlapping crack growth rate data. The cyclic conditions responsible for creep-fatigue deformation and enhanced crack growth vary with material and with temperature for a given material. The effects of environment such as time-dependent oxidation in enhancing the crack growth ra...

  20. Dynamometer Testing (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2010-11-01

    This fact sheet describes the dynamometer and its testing capabilities at the National Wind Technology Center.

  1. Heun equation, Teukolsky equation, and type-D metrics

    E-Print Network [OSTI]

    D. Batic; H. Schmid

    2007-01-15

    Starting with the whole class of type-D vacuum backgrounds with cosmological constant we show that the separated Teukolsky equation for zero rest-mass fields with spin $s=\\pm 2$ (gravitational waves), $s=\\pm 1$ (electromagnetic waves) and $s=\\pm 1/2$ (neutrinos) is an Heun equation in disguise.

  2. Maintenance Types | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    requirements of any physical asset within its operating context. Chapter 5 of the Federal Energy Management Program's O&M Best Practices Guide outlines these maintenance types in...

  3. Portfolio Manager Space Type Discussion

    Broader source: Energy.gov [DOE]

    This presentation, given through the DOE's Technical Assistance Program (TAP), provides a discussion about space/type in regards to the Portfolio Manager Initiative.

  4. Window Types | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    its U-factor. There are advantages and disadvantages to all types of frame materials, but vinyl, wood, fiberglass, and some composite frame materials provide greater...

  5. Portfolio Manager Space Type Discussion

    Broader source: Energy.gov [DOE]

    This presentation, given through the DOE's Technical Assitance Program (TAP), provides a discussion about space/type in regards to the Portfolio Manager Initiative.

  6. Long-term corrosion testing pan.

    SciTech Connect (OSTI)

    Wall, Frederick Douglas; Brown, Neil R. (Los Alamos National Laboratory, Los Alamos, NM)

    2008-08-01

    This document describes the testing and facility requirements to support the Yucca Mountain Project long-term corrosion testing needs. The purpose of this document is to describe a corrosion testing program that will (a) reduce model uncertainty and variability, (b) reduce the reliance upon overly conservative assumptions, and (c) improve model defensibility. Test matrices were developed for 17 topical areas (tasks): each matrix corresponds to a specific test activity that is a subset of the total work performed in a task. A future document will identify which of these activities are considered to be performance confirmation activities. Detailed matrices are provided for FY08, FY09 and FY10 and rough order estimates are provided for FY11-17. Criteria for the selection of appropriate test facilities were developed through a meeting of Lead Lab and DOE personnel on October 16-17, 2007. These criteria were applied to the testing activities and recommendations were made for the facility types appropriate to carry out each activity. The facility requirements for each activity were assessed and activities were identified that can not be performed with currently available facilities. Based on this assessment, a total of approximately 10,000 square feet of facility space is recommended to meet all future testing needs, given that all testing is consolidated to a single location. This report is a revision to SAND2007-7027 to address DOE comments and add a series of tests to address NWTRB recommendations.

  7. Transport Test Problems for Hybrid Methods Development

    SciTech Connect (OSTI)

    Shaver, Mark W.; Miller, Erin A.; Wittman, Richard S.; McDonald, Benjamin S.

    2011-12-28

    This report presents 9 test problems to guide testing and development of hybrid calculations for the ADVANTG code at ORNL. These test cases can be used for comparing different types of radiation transport calculations, as well as for guiding the development of variance reduction methods. Cases are drawn primarily from existing or previous calculations with a preference for cases which include experimental data, or otherwise have results with a high level of confidence, are non-sensitive, and represent problem sets of interest to NA-22.

  8. Check for peroxides every 6 months. opened test 1 test 2 test 3

    E-Print Network [OSTI]

    Pawlowski, Wojtek

    Check for peroxides every 6 months. opened test 1 test 2 test 3 date initials Check for peroxides every 6 months. opened test 1 test 2 test 3 date initials Check for peroxides every 6 months. Test strips can be obtained from EH&S, 5-8200 opened test 1 test 2 test 3 date initials Check for peroxides

  9. C-106 tank process ventilation test

    SciTech Connect (OSTI)

    Bailey, J.W.

    1998-07-20

    Project W-320 Acceptance Test Report for tank 241-C-106, 296-C-006 Ventilation System Acceptance Test Procedure (ATP) HNF-SD-W320-012, C-106 Tank Process Ventilation Test, was an in depth test of the 296-C-006 ventilation system and ventilation support systems required to perform the sluicing of tank C-106. Systems involved included electrical, instrumentation, chiller and HVAC. Tests began at component level, moved to loop level, up to system level and finally to an integrated systems level test. One criteria was to perform the test with the least amount of risk from a radioactive contamination potential stand point. To accomplish this a temporary configuration was designed that would simulate operation of the systems, without being connected directly to the waste tank air space. This was done by blanking off ducting to the tank and connecting temporary ducting and an inlet air filter and housing to the recirculation system. This configuration would eventually become the possible cause of exceptions. During the performance of the test, there were points where the equipment did not function per the directions listed in the ATP. These events fell into several different categories. The first and easiest problems were field configurations that did not match the design documentation. This was corrected by modifying the field configuration to meet design documentation and reperforming the applicable sections of the ATP. A second type of problem encountered was associated with equipment which did not operate correctly, at which point an exception was written against the ATP, to be resolved later. A third type of problem was with equipment that actually operated correctly but the directions in the ATP were in error. These were corrected by generating an Engineering Change Notice (ECN) against the ATP. The ATP with corrected directions was then re-performed. A fourth type of problem was where the directions in the ATP were as the equipment should operate, but the design of the equipment was not correct for that type of operation. To correct this problem an ECN was generated against the design documents, the equipment modified accordingly, and the ATP re-performed. The last type of problem was where the equipment operated per the direct ions in the ATP, agreed with the design documents, yet violated requirements of the Basis of Interim Operation (BIO). In this instance a Non Conformance Report (NCR) was generated. To correct problems documented on an NCR, an ECN was generated to modify the design and field work performed, followed by retesting to verify modifications corrected noted deficiencies. To expedite the completion of testing and maintain project schedules, testing was performed concurrent with construct on, calibrations and the performance of other ATP`s.

  10. Nitrate Salt Surrogate Blending Scoping Test Plan

    SciTech Connect (OSTI)

    Anast, Kurt Roy

    2015-11-13

    Test blending equipment identified in the “Engineering Options Assessment Report: Nitrate Salt Waste Stream Processing”. Determine if the equipment will provide adequate mixing of zeolite and surrogate salt/Swheat stream; optimize equipment type and operational sequencing; impact of baffles and inserts on mixing performance; and means of validating mixing performance

  11. Test of Genuine Multipartite Nonlocality Without Inequality

    E-Print Network [OSTI]

    Qing Chen; Sixia Yu; Chengjie Zhang; C. H. Lai; C. H. Oh

    2013-05-20

    In this letter we propose a set of conditions on the joint probabilities as a test of genuine multipartite nonlocality without inequality. Our test is failed by all non-signaling local models in which even nonlocal correlations among some observables (not all) are allowed as long as these correlations respect the non-signaling principle. A pass of our test by a state therefore indicates that this state cannot be simulated by any non-signaling local models, i.e., the state exhibits genuine multipartite nonlocality. It turns out that all entangled symmetric n-qubit ($n \\geq 3$) states pass our test and therefore are n-way nonlocal. Also we construct two Bell-type inequalities from our proposed test whose violations indicate genuine multipartite nonlocal correlations.

  12. Nominalization, Predication and Type Containment

    E-Print Network [OSTI]

    Kamareddine, Fairouz

    of Eindhoven, for their nancial support and hospitality during the academic year 1991{92. yKlein's work has by the uk Economic and Social Research Council. 1 #12;Abstract In an attempt to accommodate natural language, by assigning each expression a family of types. Another line of work has moved in the direction of type

  13. Archived Reference Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  14. Archived Reference Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  15. New approaches for modeling type Ia supernovae

    E-Print Network [OSTI]

    Zingale, Michael; Almgren, Ann S.; Bell, John B.; Day, Marcus S.; Rendleman, Charles A.; Woosley, Stan

    2007-01-01

    runaway in Type Ia supernovae: How to run away? oIgnition in Type Ia Supernovae. II. A Three- dimensionalnumber modeling of type Ia supernovae. I. hydrodynamics.

  16. A combined cycle engine test facility

    SciTech Connect (OSTI)

    Engers, R.; Cresci, D.; Tsai, C.

    1995-09-01

    Rocket-Based Combined-Cycle (RBCC) engines intended for missiles and/or space launch applications incorporate features of rocket propulsion systems operating in concert with airbreathing engine cycles. Performance evaluation of these types of engines, which are intended to operate from static sea level take-off to supersonic cruise or accerlerate to orbit, requires ground test capabilities which integrate rocket component testing with airbreathing engine testing. A combined cycle engine test facility has been constructed in the General Applied Science Laboratories, Inc. (GASL) Aeropropulsion Test Laboratory to meet this requirement. The facility was designed to support the development of an innovative combined cycle engine concept which features a rocket based ramjet combustor. The test requirements included the ability to conduct tests in which the propulsive force was generated by rocket only, the ramjet only and simultaneous rocket and ramjet power (combined cycle) to evaluate combustor operation over the entire engine cycle. The test facility provides simulation over the flight Mach number range of 0 to 8 and at various trajectories. The capabilities of the combined cycle engine test facility are presented.

  17. Tonopah Test Range capabilities: technical manual

    SciTech Connect (OSTI)

    Manhart, R.L.

    1982-11-01

    This manual describes Tonopah Test Range (TTR), defines its testing capabilities, and outlines the steps necessary to schedule tests on the Range. Operated by Sandia National Laboratories, TTR is a major test facility for DOE-funded weapon programs. The Range presents an integrated system for ballistic test vehicle tracking and data acquisition. Multiple radars, optical trackers, telemetry stations, a central computer complex, and combined landline/RF communications systems assure full Range coverage for any type of test. Range operations are conducted by a department within Sandia's Field Engineering Directorate. While the overall Range functions as a complete system, it is operationally divided into the Test Measurements, Instrumentation Development, and Range Operations divisions. The primary function of TTR is to support DOE weapons test activities. Management, however, encourages other Government agencies and their contractors to schedule tests on the Range which can make effective use of its capabilities. Information concerning Range use by organizations outside of DOE is presented. Range instrumentation and support facilities are described in detail. This equipment represents the current state-of-the-art and reflects a continuing commitment by TTR management to field the most effective tracking and data acquisition system available.

  18. Long-term corrosion testing plan.

    SciTech Connect (OSTI)

    Wall, Frederick Douglas; Brown, Neil R. (Los Alamos National Laboratory, Los Alamos, NM)

    2009-02-01

    This document describes the testing and facility requirements to support the Yucca Mountain Project long-term corrosion testing program. The purpose of this document is to describe a corrosion testing program that will (a) reduce model uncertainty and variability, (b) reduce the reliance upon overly conservative assumptions, and (c) improve model defensibility. Test matrices were developed for 17 topical areas (tasks): each matrix corresponds to a specific test activity that is a subset of the total work performed in a task. A future document will identify which of these activities are considered to be performance confirmation activities. Detailed matrices are provided for FY08, FY09 and FY10 and rough order estimates are provided for FY11-17. Criteria for the selection of appropriate test facilities were developed through a meeting of Lead Lab and DOE personnel on October 16-17, 2007. These criteria were applied to the testing activities and recommendations were made for the facility types appropriate to carry out each activity. The facility requirements for each activity were assessed and activities were identified that can not be performed with currently available facilities. Based on this assessment, a total of approximately 10,000 square feet of facility space is recommended to accommodate all future testing, given that all testing is consolidated to a single location. This report is a revision to SAND2008-4922 to address DOE comments.

  19. MA 266 Practice Test

    E-Print Network [OSTI]

    2015-04-12

    Spring 2015. Test 2: April 15, 2015. INSTRUCTIONS in the Test. 1. Do not open this exam booklet until told to do so. 2. There are 6 or 7 problems - one per page.

  20. MA 266 Practice Test

    E-Print Network [OSTI]

    2015-02-26

    Test 1: March 4, 2015. INSTRUCTIONS in the Test. 1. Do not open this exam booklet until told to do so. 2. There are 6 or 7 problems - one per page. 3. Show all ...

  1. High Explosives Testing

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    at Los Alamos. August 1, 2013 The design and testing for "Little Boy" took place at Gun Site The design and testing for "Little Boy" took place at Gun Site. RELATED IMAGES...

  2. Blade Testing Trends (Presentation)

    SciTech Connect (OSTI)

    Desmond, M.

    2014-08-01

    As an invited guest speaker, Michael Desmond presented on NREL's NWTC structural testing methods and capabilities at the 2014 Sandia Blade Workshop held on August 26-28, 2014 in Albuquerque, NM. Although dynamometer and field testing capabilities were mentioned, the presentation focused primarily on wind turbine blade testing, including descriptions and capabilities for accredited certification testing, historical methodology and technology deployment, and current research and development activities.

  3. Coaxial test fixture

    DOE Patents [OSTI]

    Praeg, W.F.

    1984-03-30

    This invention pertains to arrangements for performing electrical tests on contact material samples, and in particular for testing contact material test samples in an evacuated environment under high current loads. Frequently, it is desirable in developing high-current separable contact material, to have at least a preliminary analysis of selected candidate conductor materials. Testing of material samples will hopefully identify materials unsuitable for high current electrical contact without requiring incorporation of the materials into a completed and oftentimes complex structure.

  4. P-type gallium nitride

    DOE Patents [OSTI]

    Rubin, Michael (Berkeley, CA); Newman, Nathan (Montara, CA); Fu, Tracy (Berkeley, CA); Ross, Jennifer (Pleasanton, CA); Chan, James (Berkeley, CA)

    1997-01-01

    Several methods have been found to make p-type gallium nitride. P-type gallium nitride has long been sought for electronic devices. N-type gallium nitride is readily available. Discovery of p-type gallium nitride and the methods for making it will enable its use in ultraviolet and blue light-emitting diodes and lasers. pGaN will further enable blue photocathode elements to be made. Molecular beam epitaxy on substrates held at the proper temperatures, assisted by a nitrogen beam of the proper energy produced several types of p-type GaN with hole concentrations of about 5.times.10.sup.11 /cm.sup.3 and hole mobilities of about 500 cm.sup.2 /V-sec, measured at 250.degree. K. P-type GaN can be formed of unintentionally-doped material or can be doped with magnesium by diffusion, ion implantation, or co-evaporation. When applicable, the nitrogen can be substituted with other group III elements such as Al.

  5. P-type gallium nitride

    DOE Patents [OSTI]

    Rubin, M.; Newman, N.; Fu, T.; Ross, J.; Chan, J.

    1997-08-12

    Several methods have been found to make p-type gallium nitride. P-type gallium nitride has long been sought for electronic devices. N-type gallium nitride is readily available. Discovery of p-type gallium nitride and the methods for making it will enable its use in ultraviolet and blue light-emitting diodes and lasers. pGaN will further enable blue photocathode elements to be made. Molecular beam epitaxy on substrates held at the proper temperatures, assisted by a nitrogen beam of the proper energy produced several types of p-type GaN with hole concentrations of about 5{times}10{sup 11} /cm{sup 3} and hole mobilities of about 500 cm{sup 2} /V-sec, measured at 250 K. P-type GaN can be formed of unintentionally-doped material or can be doped with magnesium by diffusion, ion implantation, or co-evaporation. When applicable, the nitrogen can be substituted with other group III elements such as Al. 9 figs.

  6. Testing Monotonicity Oded Goldreich

    E-Print Network [OSTI]

    Goldreich, Oded

    to query an unknown function f : {0, 1}n {0, 1} at arguments of its choice, the test always accepts of the function to any monotone function. 1.1 Perspective Property Testing, as explicitly defined by Rubinfeld), and that such tests can be defined and performed also for other error-correcting codes such as the Hadamard code [ALM

  7. SOFTWARE TESTING Tester's Job

    E-Print Network [OSTI]

    Kundu, Sukhamay

    allows multiple different acceptable outputs for some inputs. #12;8.4 BLACK-BOX TESTING · Based a requirement of category 5 w.r.t this test case. #define WORDLEN 20 void WordCharCounts(FILE *inFile) { int iSOFTWARE TESTING Tester's Job: · Find as many faults of different kinds as he can. · Certify some

  8. Gas Test Loop Booster Fuel Hydraulic Testing

    SciTech Connect (OSTI)

    Gas Test Loop Hydraulic Testing Staff

    2006-09-01

    The Gas Test Loop (GTL) project is for the design of an adaptation to the Advanced Test Reactor (ATR) to create a fast-flux test space where fuels and materials for advanced reactor concepts can undergo irradiation testing. Incident to that design, it was found necessary to make use of special booster fuel to enhance the neutron flux in the reactor lobe in which the Gas Test Loop will be installed. Because the booster fuel is of a different composition and configuration from standard ATR fuel, it is necessary to qualify the booster fuel for use in the ATR. Part of that qualification is the determination that required thermal hydraulic criteria will be met under routine operation and under selected accident scenarios. The Hydraulic Testing task in the GTL project facilitates that determination by measuring flow coefficients (pressure drops) over various regions of the booster fuel over a range of primary coolant flow rates. A high-fidelity model of the NW lobe of the ATR with associated flow baffle, in-pile-tube, and below-core flow channels was designed, constructed and located in the Idaho State University Thermal Fluids Laboratory. A circulation loop was designed and constructed by the university to provide reactor-relevant water flow rates to the test system. Models of the four booster fuel elements required for GTL operation were fabricated from aluminum (no uranium or means of heating) and placed in the flow channel. One of these was instrumented with Pitot tubes to measure flow velocities in the channels between the three booster fuel plates and between the innermost and outermost plates and the side walls of the flow annulus. Flow coefficients in the range of 4 to 6.5 were determined from the measurements made for the upper and middle parts of the booster fuel elements. The flow coefficient for the lower end of the booster fuel and the sub-core flow channel was lower at 2.3.

  9. Section 8.1 Hypotheses and Test Procedures June 1, 2015 1 8 Tests of Hypotheses Based on a

    E-Print Network [OSTI]

    Arnold, Elizabeth A.

    that peanut oil causes colon cancer. Example: State the hypotheses for testing the claim that peanut oil and in medical terminology. Describe the Type II error in regular English and in medical terminology

  10. DOT-7A Type A packaging design guide

    SciTech Connect (OSTI)

    Kelly, D.L.

    1995-01-23

    The purpose of this Design Guide is to provide instruction for designing a U.S. Department of Transportation Specification 7A (DOT-7A) Type A packaging. Another purpose for this Design Guide is to support the evaluation and testing activities that are performed on new designs by a U.S. Department of Energy (DOE) test facility. This evaluation and testing program is called the DOT-7A Program. When an applicant has determined that a DOT-7A packaging is needed and not commercially available, a design may be created according to this document. The design should include a packaging drawing, specifications, analysis report, operating instructions, and a Packaging Qualification Checklist; all of which should be forwarded to a DOE/HQ approved test facility for evaluation and testing. This report is being submitted through the Engineering Documentation System so that it may be used for reference and information purposes.

  11. Drum drop test report

    SciTech Connect (OSTI)

    McBeath, R.S.

    1995-02-28

    Testing was performed to determine actual damage to drums when dropped from higher than currently stacked elevations. The drum configurations were the same as they are placed in storage; single drums and four drums banded to a pallet. Maximum drop weights were selected based on successful preliminary tests. Material was lost from each of the single drum tests while only a small amount of material was lost from one of the pelletized drums. The test results are presented in this report. This report also provides recommendations for further testing to determine the appropriate drum weight which can be stored on a fourth tier.

  12. Limited Test Ban Treaty

    National Nuclear Security Administration (NNSA)

    Satellite Carrying NNSA-provided Nuclear Detonation Detection Sensors http:www.nnsa.energy.govmediaroompressreleasesafsatellite

    type-date...

  13. Issues in Type IIA Uplifting

    E-Print Network [OSTI]

    Renata Kallosh; Masoud Soroush

    2007-06-09

    Moduli stabilization in the type IIA massive string theory so far was achieved only in the AdS vacua. The uplifting to dS vacua has not been performed as yet: neither the analogs of type IIB anti-D3 brane at the tip of the conifold, nor the appropriate D-terms have been identified. The hope was recently expressed that the F-term uplifting may work. We investigate this possibility in the context of a simplified version of the type IIA model developed in hep-th/0505160 and find that the F-term does not uplift the AdS vacua to dS vacua with positive CC. Thus it remains a challenging task to find phenomenologically acceptable vacua in the type IIA string theory.

  14. Pendulum detector testing device

    DOE Patents [OSTI]

    Gonsalves, J.M.

    1997-09-30

    A detector testing device is described which provides consistent, cost-effective, repeatable results. The testing device is primarily constructed of PVC plastic and other non-metallic materials. Sensitivity of a walk-through detector system can be checked by: (1) providing a standard test object simulating the mass, size and material content of a weapon or other contraband, (2) suspending the test object in successive positions, such as head, waist and ankle levels, simulating where the contraband might be concealed on a person walking through the detector system; and (3) swinging the suspended object through each of the positions, while operating the detector system and observing its response. The test object is retained in a holder in which the orientation of the test device or target can be readily changed, to properly complete the testing requirements. 5 figs.

  15. Sample Proficiency Test exercise

    SciTech Connect (OSTI)

    Alcaraz, A; Gregg, H; Koester, C

    2006-02-05

    The current format of the OPCW proficiency tests has multiple sets of 2 samples sent to an analysis laboratory. In each sample set, one is identified as a sample, the other as a blank. This method of conducting proficiency tests differs from how an OPCW designated laboratory would receive authentic samples (a set of three containers, each not identified, consisting of the authentic sample, a control sample, and a blank sample). This exercise was designed to test the reporting if the proficiency tests were to be conducted. As such, this is not an official OPCW proficiency test, and the attached report is one method by which LLNL might report their analyses under a more realistic testing scheme. Therefore, the title on the report ''Report of the Umpteenth Official OPCW Proficiency Test'' is meaningless, and provides a bit of whimsy for the analyses and readers of the report.

  16. Summary of NREL's Recent Class 8 Tractor Trailer Platooning Testing (Presentation)

    SciTech Connect (OSTI)

    Lammert, M.; Kelly, K.; Walkowicz, K.

    2014-08-01

    This presentation summarizes NREL's recent class 8 tractor trailer platooning testing, including analysis of SAE J1321 Type II fuel consumption testing, fuel consumption improvement, fuel economy and platooning position accuracy.

  17. A SOLAR TEST COLLECTOR FOR EVALUATION OF BOTH SELECTIVE AND NON-SELECTIVE ABSORBERS

    E-Print Network [OSTI]

    Lampert, C.M.

    2011-01-01

    Standards for ~sting Solar Collectors and Thermal StorageLBL-6974 Rev. e. ' A SOLAR TEST COLLECTOR FOR EVALUATION OF+ 0.66 Fig. L r2 r2 Solar test collector flow chart. Type

  18. 2007 Nissan Altima-7982 Hybrid Electric Vehicle Battery Test Results

    SciTech Connect (OSTI)

    Tyler Grey; Chester Motloch; James Francfort

    2010-01-01

    The U.S. Department of Energy's Advanced Vehicle Testing Activity conducts several different types of tests on hybrid electric vehicles, including testing hybrid electric vehicles batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of accelerated testing. This report documents the battery testing performed and battery testing results for the 2007 Nissan Altima hybrid electric vehicle (Vin Number 1N4CL21E27C177982). Testing was performed by the Electric Transportation Engineering Corporation. The Advanced Vehicle Testing Activity is part of the U.S. Department of Energy's Vehicle Technologies Program. The Idaho National Laboratory and the Electric Transportation Engineering Corporation conduct Advanced Vehicle Testing Activity for the U.S. Department of Energy.

  19. 2006 Toyota Highlander-5681 Hybrid Electric Vehicle Battery Test Results

    SciTech Connect (OSTI)

    Tyler Gray; Chester Motloch; James Francfort

    2010-01-01

    The U.S. Department of Energy's Advanced Vehicle Testing Activity conducts several different types of tests on hybrid electric vehicles, including testing hybrid electric vehicles batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of accelerated testing. This report documents the battery testing performed and battery testing results for the 2007 Toyota Highlander hybrid electric vehicle (Vin Number JTEDW21A860005681). Testing was performed by the Electric Transportation Engineering Corporation. The Advanced Vehicle Testing Activity is part of the U.S. Department of Energy's Vehicle Technologies Program. The Idaho National Laboratory and the Electric Transportation Engineering Corporation conduct Advanced Vehicle Testing Activity for the U.S. Department of Energy.

  20. 2006 Toyota Highlander-6395 Hyrid Electric Vehicle Battery Test Results

    SciTech Connect (OSTI)

    Tyler Gray; Chester Motloch; James Francfort

    2010-01-01

    The U.S. Department of Energy's Advanced Vehicle Testing Activity conducts several different types of tests on hybrid electric vehicles, including testing hybrid electric vehicles batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of accelerated testing. This report documents the battery testing performed and battery testing results for the 2007 Toyota Highlander hybrid electric vehicle (Vin Number JTEDW21A160006395). Testing was performed by the Electric Transportation Engineering Corporation. The Advanced Vehicle Testing Activity is part of the U.S. Department of Energy's Vehicle Technologies Program. The Idaho National Laboratory and the Electric Transportation Engineering Corporation conduct Advanced Vehicle Testing Activity for the U.S. Department of Energy.

  1. 2007 Toyota Camry-7129 Hybrid Electric Vehicle Battery Test Results

    SciTech Connect (OSTI)

    Tyler Gray; Chester Motloch; James Francfort

    2010-01-01

    The U.S. Department of Energy's Advanced Vehicle Testing Activity conducts several different types of tests on hybrid electric vehicles, including testing hybrid electric vehicles batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of accelerated testing. This report documents the battery testing performed and battery testing results for the 2007 Toyota Camry hybrid electric vehicle (Vin Number JTNBB46K773007129). Testing was performed by the Electric Transportation Engineering Corporation. The Advanced Vehicle Testing Activity is part of the U.S. Department of Energy's Vehicle Technologies Program. The Idaho National Laboratory and the Electric Transportation Engineering Corporation conduct Advanced Vehicle Testing Activity for the U.S. Department of Energy.

  2. STRUCTURES AND MATERIALS TEST LABORATORY

    E-Print Network [OSTI]

    Russell, Jeffrey S.

    of the test program described here was to measure the shrinkage and creep characteristics of SCC mixes used. Creep tests ................................................. 4 3. Other tests ........................... 13 Shrinkage Test Results ................................... 16 Creep test Results

  3. Partition Testing versus Random Testing: the Influence of Uncertainty

    E-Print Network [OSTI]

    Gutjahr, Walter

    detection, partition test­ ing, program testing, random testing, software testing. I. Introduction Few topics in software testing methodology seem to be more controversial than the question whetherPartition Testing versus Random Testing: the Influence of Uncertainty Walter J. Gutjahr Department

  4. Integral testing of relays and circuit breakers

    SciTech Connect (OSTI)

    Bandyopadhyay, K.K.

    1993-12-31

    Among all equipment types considered for seismic qualification, relays have been most extensively studied through testing due to a wide variation of their designs and seismic capacities. A temporary electrical discontinuity or ``chatter`` is the common concern for relays. A chatter duration of 2 milliseconds is typically used as an acceptance criterion to determine the seismic capability of a relay. Many electrical devices, on the other hand, receiving input signals from relays can safely tolerate a chatter level much greater than 2 ms. In Phase I of a test program, Brookhaven National Laboratory performed testing of many relay models using the 2-ms chatter criterion. In Phase II of the program, the factors influencing the relay chatter criterion, and impacts of relay chatter on medium and low voltage circuit breakers and lockout relays were investigated. This paper briefly describes the Phase II tests and presents the important observations.

  5. A test for second order stationarity of a time series based on the Discrete Fourier Transform

    E-Print Network [OSTI]

    Subba Rao, Suhasini

    A test for second order stationarity of a time series based on the Discrete Fourier Transform property, we construct a Portmanteau type test statistic for testing stationarity of the time series. It is shown that under the null of stationarity, the test statistic is approximately a chi square distribution

  6. MODEL COMPENSATION FOR NOISES IN TRAINING AND TEST DATA

    E-Print Network [OSTI]

    MODEL COMPENSATION FOR NOISES IN TRAINING AND TEST DATA Driss Matrouf and Jean-Luc Gauvain LIMSI on a channel model generally assume that the training data is noise-free, and the test data is noisy[1, 2, 3, 4 the channel type or the background noise characteristics is available, model com- pensation has

  7. TESTS FOR NORMALITY BASED ON DENSITY ESTIMATORS OF CONVOLUTIONS

    E-Print Network [OSTI]

    Wefelmeyer, Wolfgang

    TESTS FOR NORMALITY BASED ON DENSITY ESTIMATORS OF CONVOLUTIONS ANTON SCHICK, YISHI WANG-type kernel density estimator, goodness-of-fit test. Anton Schick was supported by NSF Grant DMS0906551. 1 #12;2 ANTON SCHICK, YISHI WANG AND WOLFGANG WEFELMEYER Instead of comparing distribution functions, we can

  8. Advanced Technology Vehicle Testing

    SciTech Connect (OSTI)

    James Francfort

    2004-06-01

    The goal of the U.S. Department of Energy's Advanced Vehicle Testing Activity (AVTA) is to increase the body of knowledge as well as the awareness and acceptance of electric drive and other advanced technology vehicles (ATV). The AVTA accomplishes this goal by testing ATVs on test tracks and dynamometers (Baseline Performance testing), as well as in real-world applications (Fleet and Accelerated Reliability testing and public demonstrations). This enables the AVTA to provide Federal and private fleet managers, as well as other potential ATV users, with accurate and unbiased information on vehicle performance and infrastructure needs so they can make informed decisions about acquiring and operating ATVs. The ATVs currently in testing include vehicles that burn gaseous hydrogen (H2) fuel and hydrogen/CNG (H/CNG) blended fuels in internal combustion engines (ICE), and hybrid electric (HEV), urban electric, and neighborhood electric vehicles. The AVTA is part of DOE's FreedomCAR and Vehicle Technologies Program.

  9. Hybrid Power Test Bed

    SciTech Connect (OSTI)

    NONE

    1996-06-01

    This document describes efforts by the National Renewable Energy Laboratory to simulate hybrid power systems. Hybrid power systems combine multiple power sources such as wind turbines, photovoltaic (PV) arrays, diesel generators, and battery storage systems. They typically are used in remote areas, away from major electric grids. The Hybrid Power Test Bed is designed to assist the U.S. wind industry in developing and testing hybrid power generation systems. Test bed capabilities, features, and equipment are described.

  10. Wind Technology Testing Center Acquires New Blade Fatigue Test...

    Broader source: Energy.gov (indexed) [DOE]

    multimegawatt wind turbine blade flap fatigue test. Addthis Related Articles DOE's New Large Blade Test Facility in Massachusetts Completes First Commercial Blade Tests...

  11. Eight plane IPND mechanical testing.

    SciTech Connect (OSTI)

    Zhao, A.; Guarino, V.; Wood, K.; Nephew, T.; Ayres, D.; Lee, A.; High Energy Physics; FNAL

    2008-03-18

    A mechanical test of an 8 plane IPND mechanical prototype, which was constructed using extrusions from the testing/tryout of the 16 cell prototype extrusion die in Argonne National Laboratory, was conducted. There were 4 vertical and 4 horizontal planes in this 8 plane IPND prototype. Each vertical plane had four 16 cell extrusions, while each horizontal plane had six 16 cell extrusions. Each plane was glued together using the formulation of Devcon adhesive, Devcon 60. The vertical extrusions used in the vertical planes shares the same dimensions as the horizontal extrusions in the horizontal planes with the average web thickness of 2.1 mm and the average wall thickness of 3.1 mm. This mechanical prototype was constructed with end-seals on the both ends of the vertical extrusions. The gaps were filled with epoxy between extrusions and end-seals. The overall dimension of IPND is 154.8 by 103.1 by 21.7 inches with the weight of approximately 1200 kg, as shown in a figure. Two similar mechanical tests of 3 layer and 11 layer prototypes have been done in order to evaluate the strength of the adhesive joint between extrusions in the NOvA detector. The test showed that the IPND prototype was able to sustain under the loading of weight of itself and scintillator. Two FEA models were built to verify the measurement data from the test. The prediction from FEA slice model seems correlated reasonably well to the test result, even under a 'rough' estimated condition for the wall thickness (from an untuned die) and an unknown property of 'garage type' extrusion. A full size of FEA 3-D model also agrees very well with the test data from strain gage readings. It is worthy to point out that the stress distribution of the structure is predominantly determined by the internal pressure, while the buckling stability relies more on the loading weight from the extrusions themselves and scintillate. Results of conducted internal pressure tests, including 3- cell, 11-cell and the IPND prototypes, have been correlated to the FEA analysis very well. The authors believe they have quite good understanding of response of the NOvA structures subjected to the internal pressure, while the understanding of buckling stability is far behind. Therefore, more effect should be laid to improve the buckling considering that the FEA analysis usually is not able accurately modeling the stability as good as the stress analysis. The IPND structure was mostly built using 'scrape' piece extrusions (whatever available in shop). Therefore, a future test should be more focus on by using a actual real extrusions, for example like Nova -27 (if a final choice is made) and extrusion from a tuned die (very important). The authors should/will repeat 11 layers test with an actual thicker piece for the vertical to verify the adhesive joint and similar large scale prototype with a symmetry case, either 9 or 11 layers with the dial indicator on the both side.

  12. Regional Test Centers (RTCs)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    has established five Regional Test Centers (RTCs) across the United States to independently validate the performance and reliability of photovoltaic (PV) systems in different...

  13. Leak test fitting

    DOE Patents [OSTI]

    Pickett, Patrick T. (Kettering, OH)

    1981-01-01

    A hollow fitting for use in gas spectrometry leak testing of conduit joints is divided into two generally symmetrical halves along the axis of the conduit. A clip may quickly and easily fasten and unfasten the halves around the conduit joint under test. Each end of the fitting is sealable with a yieldable material, such as a piece of foam rubber. An orifice is provided in a wall of the fitting for the insertion or detection of helium during testing. One half of the fitting also may be employed to test joints mounted against a surface.

  14. Test 1 Solutions

    E-Print Network [OSTI]

    Microsoft account

    2015-03-03

    Mar 1, 2015 ... Test 1. Spring 2015. February 18, 2015. 1. (30 points) Christian has started to work today at Spears Corporation. Today is Christian's 42nd.

  15. The Phenix ultimate natural convection test

    SciTech Connect (OSTI)

    Gauthe, P.; Pialla, D.; Tenchine, D.; Vasile, A.; Rochwerger, D.

    2012-07-01

    The French sodium cooled fast reactor Phenix was shut down in 2009 after 35 years of operation. Before decommissioning, a final set of tests were performed by the CEA during 9 months. Several topics were involved such as thermal hydraulics, core physics and fuel behaviour. Among these ultimate experiments, two thermal hydraulic tests were performed: an asymmetrical test consisting in a trip of one secondary pump and a natural convection test in the primary circuit. Recognizing the unique opportunity offered by these Phenix ultimate tests, IAEA decided in 2007 to launch a Coordinated Research Project (CRP) devoted to benchmarking analyses with system codes on the Phenix natural convection test. One objective of the natural convection test in Phenix reactor is the assessment of the CATHARE system code for safety studies on future and advanced sodium cooled fast reactors. The aim of this paper is to describe this test, which was performed on June 22-23, 2009, and the associated benchmark specifications for the CRP work. The paper reminds briefly the Phenix reactor with the main physical parameters and the instrumentation used during the natural convection test. After that, the test scenario is described: - initial state at a power of 120 MWth, - test beginning resulting from a manual dry out of the two steam generators, - manual scram, - manual trip on the three primary pumps without back-up by pony motors, - setting and development of natural convection in the primary circuit, in a first phase without significant heat sink in the secondary circuits and in a second phase with significant heat sink in the secondary circuits, by opening the casing of steam generators to create an efficient heat sink, by air natural circulation in the steam generators casing. The benchmark case ends after this second phase, which corresponds to the experimental test duration of nearly 7 hours. The paper presents also the benchmark specifications data supplied by the CEA to all participants of this CRP in order to perform calculations (core, primary circuit, primary pumps, IHX, shutdown system, operating parameters, test scenario and real test conditions). Finally, main test results and analyses are presented including the evolution of the core and of the heat exchangers inlet and outlet temperatures, and some local temperature measurements. The natural convection has been easily set up in the pool type reactor Phenix with different boundary conditions at the secondary side, with or without heat sink. The data obtained during this unique test represent some very useful and precious results for the development of SFR in a wide range of thematic such as numerical methods dedicated to thermal-hydraulics safety analyses (system codes, CFD codes and coupling system and CFD codes) and instrumentation. (authors)

  16. Type Checking Type Classes Tobias Nipkow and Christian Prehofer

    E-Print Network [OSTI]

    . The judgement : fC1 ::: Cng is a compact form of the conjunction : C1 ^ ::: ^ : Cn. Alternatively we may think of fC1 ::: Cng as a notation for C1 \\ :::\\ Cn, the intersection of the types belonging to the classes C

  17. Type Ia Supernova Explosion Models

    E-Print Network [OSTI]

    W. Hillebrandt; J. C. Niemeyer

    2000-06-21

    Because calibrated light curves of Type Ia supernovae have become a major tool to determine the local expansion rate of the Universe and also its geometrical structure, considerable attention has been given to models of these events over the past couple of years. There are good reasons to believe that perhaps most Type Ia supernovae are the explosions of white dwarfs that have approached the Chandrasekhar mass, M_ch ~ 1.39 M_sun, and are disrupted by thermonuclear fusion of carbon and oxygen. However, the mechanism whereby such accreting carbon-oxygen white dwarfs explode continues to be uncertain. Recent progress in modeling Type Ia supernovae as well as several of the still open questions are addressed in this review. Although the main emphasis will be on studies of the explosion mechanism itself and on the related physical processes, including the physics of turbulent nuclear combustion in degenerate stars, we also discuss observational constraints.

  18. Dark matter ignition of type Ia supernovae

    E-Print Network [OSTI]

    Bramante, Joseph

    2015-01-01

    Recent studies of low redshift type Ia supernovae (SNIa) indicate that half explode from less than Chandrasekhar mass white dwarfs, implying ignition must proceed from something besides the canonical criticality of Chandrasekhar mass SNIa progenitors. We show that $0.1-10$ PeV mass asymmetric dark matter, with imminently detectable nucleon scattering interactions, can accumulate to the point of self-gravitation in a white dwarf and collapse, shedding gravitational potential energy by scattering off nuclei, thereby heating the white dwarf and igniting the flame front that precedes SNIa. We combine data on SNIa masses with data on the ages of SNIa-adjacent stars. This combination reveals a $ 3 \\sigma$ inverse correlation between SNIa masses and ignition ages, which could result from increased capture of dark matter in 1.4 versus 1.1 solar mass white dwarfs. Future studies of SNIa in galactic centers will provide additional tests of dark-matter-induced type Ia ignition. Remarkably, both bosonic and fermionic SNI...

  19. Standard Test Method for Sandwich Corrosion Test

    E-Print Network [OSTI]

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  20. Role of inflammation and endothelial dysfunction of coronary arterioles in type 2 diabetes 

    E-Print Network [OSTI]

    Yang, Ji Yeon

    2009-05-15

    . The interaction between TNFa and monocyte chemoattractant protein-1 (MCP-1) may contribute to the evolution of vascular inflammation and endothelial dysfunctionin coronary arterioles in type 2 diabetes. To test this hypothesis, endothelium...

  1. Type curve analysis for naturally fractured reservoirs (infinite-acting reservoir case): a new approach 

    E-Print Network [OSTI]

    Angel Restrepo, Juan Alejandro

    2000-01-01

    . The objectives of this work are as follows: First, we generated new type curves for the analysis of pressure drawdown and buildup tests performed in naturally fractured reservoirs. Next, we develop a systematic approach for the analysis and interpretation...

  2. Coaxial test fixture

    DOE Patents [OSTI]

    Praeg, Walter F. (Palos Park, IL)

    1986-01-01

    An assembly is provided for testing one or more contact material samples in a vacuum environment. The samples are positioned as an inner conductive cylinder assembly which is mounted for reciprocal vertical motion as well as deflection from a vertical axis. An outer conductive cylinder is coaxially positioned around the inner cylinder and test specimen to provide a vacuum enclosure therefor. A power source needed to drive test currents through the test specimens is connected to the bottom of each conductive cylinder, through two specially formed conductive plates. The plates are similar in form, having a plurality of equal resistance current paths connecting the power source to a central connecting ring. The connecting rings are secured to the bottom of the inner conductive assembly and the outer cylinder, respectively. A hydraulic actuator is also connected to the bottom of the inner conductor assembly to adjust the pressure applied to the test specimens during testing. The test assembly controls magnetic forces such that the current distribution through the test samples is symmetrical and that contact pressure is not reduced or otherwise disturbed.

  3. Advanced Test Reactor Tour

    SciTech Connect (OSTI)

    Miley, Don

    2011-01-01

    The Advanced Test Reactor at Idaho National Laboratory is the foremost nuclear materials test reactor in the world. This virtual tour describes the reactor, how experiments are conducted, and how spent nuclear fuel is handled and stored. For more information about INL research, visit http://www.facebook.com/idahonationallaboratory.

  4. Testing for Subcellular Randomness

    E-Print Network [OSTI]

    Babatunde O. Okunoye

    2008-01-29

    Statistical tests were conducted on 1,000 numbers generated from the genome of Bacteriophage T4, obtained from GenBank with accession number AF158101.The numbers passed the non-parametric, distribution-free tests.Deoxyribonucleic acid was discovered to be a random number generator, existent in nature.

  5. Advanced Test Reactor Tour

    ScienceCinema (OSTI)

    Miley, Don

    2013-05-28

    The Advanced Test Reactor at Idaho National Laboratory is the foremost nuclear materials test reactor in the world. This virtual tour describes the reactor, how experiments are conducted, and how spent nuclear fuel is handled and stored. For more information about INL research, visit http://www.facebook.com/idahonationallaboratory.

  6. Dark fleshed varieties (Bing type) in regular type, light fleshed varieties (Rainier type) in italics Sweet Cherries

    E-Print Network [OSTI]

    Dark fleshed varieties (Bing type) in regular type, light fleshed varieties (Rainier type and Royalton. For more information about these and other varieties, visit our web site at www

  7. Kauai Test Facility

    SciTech Connect (OSTI)

    Hay, R.G.

    1982-01-01

    The Kauai Test Facility (KTF) is a Department of Energy rocket launch facility operated by Sandia National Laboratories. Originally it was constructed in support of the high altitude atmospheric nuclear test phase of operation Dominic in the early 1960's. Later, the facility went through extensive improvement and modernization to become an integral part of the Safeguard C readiness to resume nuclear testing program. Since its inception and build up, in the decade of the sixties and the subsequent upgrades of the seventies, range test activities have shifted from full scale test to emphasis on research and development of materials and components, and to making high altitude scientific measurements. Primarily, the facility is intended to be utilized in support of development programs at the DOE weapons laboratories, however, other organizations may make use of the facility on a non-interface basis. The physical components at KTF and their operation are described.

  8. Nanomechanical testing system

    DOE Patents [OSTI]

    Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David

    2014-07-08

    An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.

  9. Edit Test Options Page 1 Edit Test Options

    E-Print Network [OSTI]

    Xu, Shouhuai

    Edit Test Options Page 1 Edit Test Options Format Test Information 1. Enter a Name for the Test. 2. Choose a color for the title text of the Test. (Optional) 3. Enter a Description in the Text Box. The description is visible to Students before they click on the link to take the Test. (Optional) 4. If you want

  10. Report on PV Test Sites and Test Prepared for the

    E-Print Network [OSTI]

    Report on PV Test Sites and Test Protocols Prepared for the U.S. Department of Energy Office`i Distributed Energy Resource Technologies for Energy Security Revised Task 8 Deliverable PV Test Sites and Test. #12;1 Report on PV Test Sites and Test Protocols Table of Contents 1. Introduction

  11. CC Pressure Test

    SciTech Connect (OSTI)

    Dixon, K.; /Fermilab

    1990-07-12

    The inner vessel heads including bypass and beam tubes had just been welded into place and dye penetrant checked. The vacuum heads were not on at this time but the vacuum shell was on covering the piping penetrating into the inner vessel. Signal boxes with all feed through boards, the instrumentation box, and high voltage boxes were all installed with their pump outs capped. All 1/4-inch instrumentation lines were terminated at their respective shutoff valves. All vacuum piping used for pumping down the inner vessel was isolated using o-ring sealed blind flanges. PV215A (VAT Series 12), the 4-inch VRC gate valve isolating the cyropump, and the rupture disk had to be removed and replaced with blind flanges before pressurizing due to their pressure limitations. Stresses in plates used as blind flanges were checked using Code calcualtions. Before the CC test, vacuum style blanks and clamps were hydrostatically pressure tested to 150% of the maximum test pressure, 60 psig. The Code inspector and Research Division Safety had all given their approval to the test pressure and procedure prior to filling the vessel with argon. The test was a major success. Based on the lack of any distinguishable pressure drop indicated on the pressure gages, the vessel appeared to be structurally sound throughout the duration of the test (approx. 3 hrs.). A major leak in the instrumentation tubing was discovered at half of the maximum test pressure and was quickly isolated by crimping and capping with a compression fitting. There were some slight deviations in the actual procedure used. The 44 psig relief valve located just outside the cleanroom had to be capped until the pressure in the vessel indicated 38 psi. This was to allow higher supply pressures and hence, higher flows through the pressurizing line. Also, in order to get pressure readings at the cryostat without exposing any personnel to the potentially dangerous stored energy near the maximum test pressure, a camera was installed at the top of the vessel to view the indicator mounted there. The monitor was viewed at the ante room adjacent to the cleanroom. The holding pressure of 32 psig (4/5 of the maximum test pressure) was only maintained for about 20 minutes instead of the half hour recommendation in the procedure. We felt that this was sufficient time to Snoop test and perform the pressure drop test. After the test was completed, the inspector for CBI Na-Con and the Research Divison Safety Officer signed all of required documentation.

  12. Rapid prototype and test

    SciTech Connect (OSTI)

    Gregory, D.L.; Hansche, B.D.

    1996-06-01

    In order to support advanced manufacturing, Sandia has acquired the capability to produce plastic prototypes using stereolithography. Currently, these prototypes are used mainly to verify part geometry and ``fit and form`` checks. This project investigates methods for rapidly testing these plastic prototypes, and inferring from prototype test data actual metal part performance and behavior. Performances examined include static load/stress response, and structural dynamic (modal) and vibration behavior. The integration of advanced non-contacting measurement techniques including scanning laser velocimetry, laser holography, and thermoelasticity into testing of these prototypes is described. Photoelastic properties of the epoxy prototypes to reveal full field stress/strain fields are also explored.

  13. Types of JavaO Types: Types A, B, C are

    E-Print Network [OSTI]

    Börger, Egon

    .Meth(Exps) | super.Meth(Exps) Copyright c 2002 Robert F. St¨ark, Computer Science Department, ETH Z[ ] Serializable. If A B and A, B are reference types, then A[ ] B[ ]. Copyright c 2002 Robert F. St¨ark, Computer not equal (references) Copyright c 2002 Robert F. St¨ark, Computer Science Department, ETH Z

  14. Operational Semantics and Polymorphic Type Inference 

    E-Print Network [OSTI]

    Tofte, Mads

    1988-01-01

    Three languages with polymorphic type disciplines are discussed, namely the ?-calculus with Milner's polymorphic type discipline; a language with imperative features (polymorphic references); and a skeletal module language ...

  15. Tridiagonal pairs of Krawtchouk type

    E-Print Network [OSTI]

    Ito, Tatsuro

    2007-01-01

    Let $K$ denote an algebraically closed field with characteristic 0 and let $V$ denote a vector space over $K$ with finite positive dimension. Let $A,A^*$ denote a tridiagonal pair on $V$ with diameter $d$. We say that $A,A^*$ has Krawtchouk type whenever the sequence $\\lbrace d-2i\\rbrace_{i=0}^d$ is a standard ordering of the eigenvalues of $A$ and a standard ordering of the eigenvalues of $A^*$. Assume $A,A^*$ has Krawtchouk type. We show that there exists a nondegenerate symmetric bilinear form $$ on $V$ such that $= $ and $= $ for $u,v\\in V$. We show that the following tridiagonal pairs are isomorphic: (i) $A,A^*$; (ii) $-A,-A^*$; (iii) $A^*,A$; (iv) $-A^*,-A$. We give a number of related results and conjectures.

  16. Soil Testing Lab 

    E-Print Network [OSTI]

    Unknown

    2011-08-17

    Friction factor data are important for better prediction of leakage and rotordynamic coefficients of gas annular seals. A flat-plate test rig is used to determine friction factor of hole-pattern/honeycomb flat-plate surfaces ...

  17. Solutions to Test 3

    E-Print Network [OSTI]

    jeffb_000

    2014-08-16

    Math 373. Test 3. Spring 2014. April 8, 2014. 1. Yujin can buy each of the following bonds for a price of P . The bonds are: a. A 10 year zero coupon bond ...

  18. Solutions to Test 2

    E-Print Network [OSTI]

    Microsoft account

    2015-08-05

    Math 373. Spring 2015. Test 2. March 10, 2015. 1. Linhan borrows 100,000 at an annual effective interest rate of 5%. Linhan will repay the loan with level annual ...

  19. Testing existence of antigravity

    E-Print Network [OSTI]

    Dragan Slavkov Hajdukovic

    2006-02-12

    After a brief review of arguments in favor of antigravity (as gravitational repulsion between matter and antimatter) we present a simple idea for an experimental test using antiprotons. Different experimental realizations of the same basic idea are considered

  20. Solutions to Test 2

    E-Print Network [OSTI]

    Microsoft account

    2015-01-14

    Jan 14, 2015 ... Test 2. Fall 2014. October 28, 2014. 1. Joon is going to buy a 10 year callable bond. The bond matures for 15,000 and pays semi-annual.

  1. Solutions to Test 3

    E-Print Network [OSTI]

    Microsoft account

    2015-04-02

    Apr 2, 2015 ... Test 3. Fall 2014. November 18, 2014. 1. The preferred stock of Oldham Company pays a quarterly dividend of 8. The next dividend is due in 1 ...

  2. Solutions to Test 1

    E-Print Network [OSTI]

    Microsoft account

    2015-08-05

    Math 373. Test 1. Spring 2015. February 17, 2015. 1. Hannah is the beneficiary of a trust that will pay her an annual payment of 10,000 with the first payment ...

  3. Type Ia Supernovae: Spectroscopic Surprises

    E-Print Network [OSTI]

    David Branch

    2003-10-23

    Recent observations have extended the range of diversity among spectra of Type Ia supernovae. I briefly discuss SN Ia explosion models in the spectroscopic context, the observed diversity, and some recent results from direct analysis with the Synow code for one normal and two peculiar SNe Ia. Relating the observational manifestations of diversity to their physical causes is looking like an ever more challenging problem.

  4. see Type I decision error see Type II decision error

    E-Print Network [OSTI]

    . M ALARA 2-5; 5-52; 8-21, 27; C-8 to 10 alpha () radiation 4-6, 7; 7-15 analysis 7-22 detection background (radiation) activity 5-10, 11 decommissioning 4-13 detection sensitivity 6-37, 39 to 49 ground to 21; A-5 background radiation 4-13 data points 5-25 to 31 P 5-27 r relative shift WRS test 5

  5. Testing of GFL Geosiphon

    SciTech Connect (OSTI)

    Steimke, J.L.

    2001-07-10

    A full-scale, transparent replica of a GeoSiphon was constructed in the TFL to test a new concept, using a solar powered vacuum pump to remove accumulated gases from the air chamber. It did not have a treatment cell containing iron filings as do the actual TNX GeoSiphons in the field, but it was accurate in all other respects. The gas generation that is observed in an actual GeoSiphon was simulated by air injection at the inlet of the TFL GeoSiphon. After facility shakedown, three stages of testing were conducted: verification testing, parametric testing and long term testing. In verification testing, the TFL GeoSiphon was used to reproduce a particular test at TNX in which the water flowrate decreased gradually as the result of air accumulation at the crest of a siphon without an air chamber. For this test the vacuum pump was not used and the air chamber was initially filled with air rather than water. Agreement between data from the TNX GeoSiphon and the TFL GeoSiphon was good, which gave confidence that the TFL GeoSiphon was a good hydraulic representation of the TNX GeoSiphon. For the remaining tests, the solar powered vacuum pump and air chamber were used. In parametric testing, steady state runs were made for water flowrates ranging from 1 gpm to 19 gpm, air injection rates ranging from 0 to 77 standard cc/min and outfall line angles ranging from vertical to 60 degrees from vertical. In all cases, the air chamber and vacuum pump removed nearly all of the air and the GeoSiphon operated without problems. In long term testing, the GeoSiphon was allowed to run continuously for 21 days at one set of conditions. During this time the solar cell kept the storage battery fully charged at all times and the control circuit for the vacuum pump operated reliably. The solar panel was observed to have a large excess capacity when used with the vacuum pump. With two changes, the concept of using a solar powered vacuum pump attached to an air chamber should be ready for long term use in the field. Those changes are to insulate the air chamber of the GeoSiphon so it will not freeze in the winter and to make the tank from steel rather than transparent plastic.

  6. Low Power Test-Compression for High Test-Quality and Low Test-Data Volume

    E-Print Network [OSTI]

    Low Power Test-Compression for High Test-Quality and Low Test-Data Volume Vasileios Tenentes,kabousia}@cs.uoi.gr Abstract--Test data decompressors targeting low power scan testing introduce significant amount. In addition, low power decompression needs additional control data which increase the overall volume of test

  7. Architectures of Test Automation 1 High Volume Test AutomationHigh Volume Test Automation

    E-Print Network [OSTI]

    Architectures of Test Automation 1 High Volume Test AutomationHigh Volume Test Automation Cem Kaner Institute of Technology October 2003 #12;Architectures of Test Automation 2 Acknowledgements developed a course on test automation architecture, and in the Los Altos Workshops on Software Testing

  8. 2007 Toyota Camry-6330 Hybrid Electric Vehicle Battery Test Results

    SciTech Connect (OSTI)

    Tyler Gray; Chester Motloch; James Francfort

    2010-01-01

    The U.S. Department of Energy's Advanced Vehicle Testing Activity (AVTA) conducts several different types of tests on hybrid electric vehicles (HEVs), including testing hybrid electric vehicles batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of accelerated testing. This report documents the battery testing performed and battery testing results for the 2007 Toyota Camry hybrid electric vehicle (Vin Number JTNBB46K673006330). Testing was performed by the Electric Transportation Engineering Corporation. The AVTA is part of the U.S. Department of Energy's Vehicle Technologies Program. The Idaho National Laboratory and the Electric Transportation Engineering Corporation conduct AVTA for the U.S. Department of Energy.

  9. 2007 Nissan Altima-2351 Hybrid Electric Vehicle Battery Test Results

    SciTech Connect (OSTI)

    Tyler Gray; Chester Motloch; James Francfort

    2010-01-01

    The U.S. Department of Energy's (DOE) Advanced Vehicle Testing Activity (AVTA) conducts several different types of tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of on-road accelerated testing. This report documents the battery testing performed and the battery testing results for the 2007 Nissan Altima HEV, number 2351 (VIN 1N4CL21E87C172351). The battery testing was performed by the Electric Transportation Engineering Corporation (eTec). The Idaho National Laboratory and eTec conduct the AVTA for DOE’s Vehicle Technologies Program.

  10. Baseline Test Specimen Machining Report

    SciTech Connect (OSTI)

    mark Carroll

    2009-08-01

    The Next Generation Nuclear Plant (NGNP) Project is tasked with selecting a high temperature gas reactor technology that will be capable of generating electricity and supplying large amounts of process heat. The NGNP is presently being designed as a helium-cooled high temperature gas reactor (HTGR) with a large graphite core. The graphite baseline characterization project is conducting the research and development (R&D) activities deemed necessary to fully qualify nuclear-grade graphite for use in the NGNP reactor. Establishing nonirradiated thermomechanical and thermophysical properties by characterizing lot-to-lot and billet-to-billet variations (for probabilistic baseline data needs) through extensive data collection and statistical analysis is one of the major fundamental objectives of the project. The reactor core will be made up of stacks of graphite moderator blocks. In order to gain a more comprehensive understanding of the varying characteristics in a wide range of suitable graphites, any of which can be classified as “nuclear grade,” an experimental program has been initiated to develop an extensive database of the baseline characteristics of numerous candidate graphites. Various factors known to affect the properties of graphite will be investigated, including specimen size, spatial location within a graphite billet, specimen orientation within a billet (either parallel to [P] or transverse to [T] the long axis of the as-produced billet), and billet-to-billet variations within a lot or across different production lots. Because each data point is based on a certain position within a given billet of graphite, particular attention must be paid to the traceability of each specimen and its spatial location and orientation within each billet. The evaluation of these properties is discussed in the Graphite Technology Development Plan (Windes et. al, 2007). One of the key components in the evaluation of these graphite types will be mechanical testing on specimens drawn from carefully controlled sections of each billet. To this end, this report will discuss the machining of the first set of test specimens that will be evaluated in this program through tensile, compressive, and flexural testing. Validation that the test specimens have been produced to the tolerances required by the applicable ASTM standards, and to the quality control levels required by this program, will demonstrate the viability of sending graphite to selected suppliers that will provide valuable and certifiable data to future data sets that are integral to the NGNP program and beyond.

  11. Test Anxiety Tips to Ease Your Test Anxiety

    E-Print Network [OSTI]

    Kunkle, Tom

    Test Anxiety Tips to Ease Your Test Anxiety Adapted from: Study Guides and Strategies website, Overcoming test anxiety Test taking can be overwhelming and can cause a lot of anxiety. Try these tips to ease your anxiety through the testing process! Before Approach the exam with confidence Be prepared

  12. Regulatory compliance guide for DOT-7A type A packaging design

    SciTech Connect (OSTI)

    Kelly, D.L.

    1996-06-04

    The purpose of this guide is to provide instruction for assuring that the regulatory design requirements for a DOT-7A Type A packaging are met. This guide also supports the testing and evaluation activities that are performed on new packaging designs by a DOE-approved test facility through the DOE`s DOT-7A Test Program. This Guide was updated to incorporate regulatory changes implemented by HM-169A (49 CFR, `Transportation`).

  13. Mining Test Cases To Improve Software Maintenance

    E-Print Network [OSTI]

    Ziftci, Celal

    Finding TestTracing Features to Test Cases . . . . . . . . . . . . . . .5.4.2 Finding Test Intents Using

  14. Corrosion testing using isotopes

    DOE Patents [OSTI]

    Hohorst, F.A.

    1995-12-05

    A method is described for determining the corrosion behavior of a material with respect to a medium in contact with the material by: implanting a substantially chemically inert gas in a matrix so that corrosion experienced by the material causes the inert gas to enter the medium; placing the medium in contact with the material; and measuring the amount of inert gas which enters the medium. A test sample of a material whose resistance to corrosion by a medium is to be tested is described composed of: a body of the material, which body has a surface to be contacted by the medium; and a substantially chemically inert gas implanted into the body to a depth below the surface. A test sample of a material whose resistance to corrosion by a medium is to be tested is described composed of: a substrate of material which is easily corroded by the medium, the substrate having a surface; a substantially chemically inert gas implanted into the substrate; and a sheet of the material whose resistance to corrosion is to be tested, the sheet being disposed against the surface of the substrate and having a defined thickness. 3 figs.

  15. Wheel-type magnetic refrigerator

    DOE Patents [OSTI]

    Barclay, J.A.

    1982-01-20

    The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load.

  16. Wheel-type magnetic refrigerator

    DOE Patents [OSTI]

    Barclay, J.A.

    1983-10-11

    The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load. 7 figs.

  17. Window Types | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirley Ann Jackson About1996HowFOAShowingFuelWeatherize » AirareAbout Key ActivitiesWindow Types

  18. Window Types | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative FuelsofProgram: Report1538-1950DepartmentWaveWind Program R&DResearchWindow Types

  19. Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Pilot-Scale Test Results

    SciTech Connect (OSTI)

    Gary M. Blythe

    2006-03-01

    This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, ''Field Testing of a Wet FGD Additive.'' The objective of the project is to demonstrate the use of a flue gas desulfurization (FGD) additive, Degussa Corporation's TMT-15, to prevent the reemissions of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate that the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine TMT salt that can be separated from the FGD liquor and bulk solid byproducts for separate disposal. The project will conduct pilot and full-scale tests of the TMT-15 additive in wet FGD absorbers. The tests are intended to determine required additive dosage requirements to prevent Hg{sup 0} reemissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Power River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, TXU Generation Company LP, Southern Company, and Degussa Corporation. TXU Generation has provided the Texas lignite/PRB co-fired test site for pilot FGD tests, Monticello Steam Electric Station Unit 3. Southern Company is providing the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot and full-scale jet bubbling reactor (JBR) FGD systems to be tested. A third utility, to be named later, will provide the high-sulfur Eastern bituminous coal full-scale FGD test site. Degussa Corporation is providing the TMT-15 additive and technical support to the test program. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves management and reporting. The other four tasks involve field testing on FGD systems, either at pilot or full scale. The four tasks include: Task 2 - Pilot Additive Testing in Texas Lignite Flue Gas; Task 3 - Full-scale FGD Additive Testing in High Sulfur Eastern Bituminous Flue Gas; Task 4 - Pilot Wet Scrubber Additive Tests at Yates; and Task 5 - Full-scale Additive Tests at Plant Yates. This topical report presents the results from the Task 2 and Task 4 pilot-scale additive tests. The Task 3 and Task 5 full-scale additive tests will be conducted later in calendar year 2006.

  20. Pseudofunctional Delay Tests For High Quality Small Delay Defect Testing 

    E-Print Network [OSTI]

    Lahiri, Shayak

    2012-02-14

    Testing integrated circuits to verify their operating frequency, known as delay testing, is essential to achieve acceptable product quality. The high cost of functional testing has driven the industry to automatically-generated ...

  1. Directed Random Testing Carlos Pacheco

    E-Print Network [OSTI]

    testing can quickly generate many tests, is easy to implement, scales to large software applications, and reveals software errors. But it tends to generate many tests that are illegal or that exercise the same approach to test generation that overcomes these limitations, by combining a bottom-up generation of tests

  2. RF test bench automation Description

    E-Print Network [OSTI]

    Dobigeon, Nicolas

    RF test bench automation Description: Callisto would like to implement automated RF test bench. Three RF test benches have to be studied and automated: LNA noise temperature test bench LNA gain phase of the test benches and an implementation of the automation phase. Tasks: Noise temperature

  3. TESTING SERVICES 1600 Holloway Avenue

    E-Print Network [OSTI]

    TESTING SERVICES 1600 Holloway Avenue SSB One Stop San Francisco, CA 94132 Tel: 415/338-2271 Fax: 415/338-0589 e-mail: testing@sfsu.edu web: www.sfsu.edu/~testing TESTING ACCOMMODATIONS REQUEST FORM) Email Address: Social Security or SF State ID: (not both) Name of Test to be Taken

  4. Brine migration test for Asse Mine, Federal Republic of Germany: final test plan

    SciTech Connect (OSTI)

    Not Available

    1983-07-01

    The United States and the Federal Republic of Germany (FRG) will conduct a brine migration test in the Asse Salt Mine in the FRG as part of the US/FRG Cooperative Radioactive Waste Management Agreement. Two sets of two tests each will be conducted to study both liquid inclusion migration and vapor migration in the two salt types chosen for the experiments: (1) pure salt, for its characteristics similar to the salt that might occur in potential US repositories, and (2) transitional salt, for its similarity to the salt that might occur in potential repositories in Germany.

  5. COMPARISON OF SHEAR STRENGTH OF CERAMIC JOINTS DETERMINED BY VARIOUS TEST METHODS WITH SMALL SPECIMENS

    SciTech Connect (OSTI)

    Shih, Chunghao Phillip; Katoh, Yutai; Kiggans Jr, James O; Koyanagi, Takaaki; Khalifa, Hesham; Back, Christina A.; Hinoki, Tatsuya; Ferraris, Monica

    2015-01-01

    Four different shear test methods i.e. doubled notched shear test, asymmetrical four point bend test, Iosipescu test, and torsion test, were investigated for their ability to evaluate one standard SiC to SiC ceramic brittle joint while using small size specimens. Double notched shear test showed higher stress concentration at the notch base and a lower nominal shear strength. Both asymmetrical four point bend test and Iosipescu test utilized epoxy jointed metal extensors, which failed during test and caused misalignment and tensile type of failure. Torsion test can deliver true shear loading. However, base material failure was observed for the torsion joint samples in this study. None of the tests can successfully induce true shear failure of the joint because the joint is stronger and tougher than the SiC substrate. Torsion test appears to be promising because of the pure shear loading, less stress concentration, and easy alignment.

  6. Certification testing of the Los Alamos National Laboratory Heat Source/Radioisotopic Thermoelectric Generator shipping container

    SciTech Connect (OSTI)

    Bronowski, D.R.; Madsen, M.M.

    1991-09-01

    The Heat Source/Radioisotopic Thermoelectric Generator shipping counter is a Type B packaging currently under development by Los Alamos National Laboratory. Type B packaging for transporting radioactive material is required to maintain containment and shielding after being exposed to normal and hypothetical accident environments defined in Title 10 of the Code of Federal Regulations Part 71. A combination of testing and analysis is used to verify the adequacy of this packaging design. This report documents the testing portion of the design verification. Six tests were conducted on a prototype package: a water spray test, a 4-foot normal conditions drop test, a 30-foot drop test, a 40-inch puncture test, a 30-minute thermal test, and an 8-hour immersion test.

  7. Alternative Neutron Detection Testing Summary

    SciTech Connect (OSTI)

    Kouzes, Richard T.; Ely, James H.; Erikson, Luke E.; Kernan, Warnick J.; Lintereur, Azaree T.; Siciliano, Edward R.; Stromswold, David C.; Woodring, Mitchell L.

    2010-04-08

    Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. Most currently deployed radiation portal monitors (RPMs) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large area neutron detector. This type of neutron detector is used in the TSA and other RPMs installed in international locations and in the Ludlum and Science Applications International Corporation RPMs deployed primarily for domestic applications. There is a declining supply of 3He in the world and, thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride-filled proportional counters, 2) Boron-lined proportional counters, 3) Lithium-loaded glass fibers, and 4) Coated wavelength-shifting plastic fibers. Reported here is a summary of the testing carried out at Pacific Northwest National Laboratory on these technologies to date, as well as measurements on 3He tubes at various pressures. Details on these measurements are available in the referenced reports. Sponsors of these tests include the Department of Energy (DOE), Department of Homeland Security (DHS), and the Department of Defense (DoD), as well as internal Pacific Northwest National Laboratory funds.

  8. Request for Information: Operation of Regional Test Center Test...

    Broader source: Energy.gov (indexed) [DOE]

    Contact Us Offices Solicitation Title: Request for Information: Operation of Regional Test Center Test Bed Located at SolarTAC Funding Number: DE-FOA-0001454 Description: The...

  9. Side-by-Side Testing of Water Heating Systems: Results from the 2009-2010 Evaluation

    Broader source: Energy.gov [DOE]

    The performance of seven differing types of residential water heating systems was compared in a side-by-side test configuration over a full year period. The Hot Water System Laboratory (HWS Lab) test facility at the Florida Solar Energy Center (FSEC) in Cocoa, FL was used for the tests.

  10. Pulse Jet Mixing Tests With Noncohesive Solids

    SciTech Connect (OSTI)

    Meyer, Perry A.; Bamberger, Judith A.; Enderlin, Carl W.; Fort, James A.; Wells, Beric E.; Sundaram, S. K.; Scott, Paul A.; Minette, Michael J.; Smith, Gary L.; Burns, Carolyn A.; Greenwood, Margaret S.; Morgen, Gerald P.; Baer, Ellen BK; Snyder, Sandra F.; White, Michael; Piepel, Gregory F.; Amidan, Brett G.; Heredia-Langner, Alejandro; Bailey, Sharon A.; Bower, John C.; Denslow, Kayte M.; Eakin, David E.; Elmore, Monte R.; Gauglitz, Phillip A.; Guzman, Anthony D.; Hatchell, Brian K.; Hopkins, Derek F.; Hurley, David E.; Johnson, Michael D.; Kirihara, Leslie J.; Lawler, Bruce D.; Loveland, Jesse S.; Mullen, O Dennis; Pekour, Mikhail S.; Peters, Timothy J.; Robinson, Peter J.; Russcher, Michael S.; Sande, Susan; Santoso, Christian; Shoemaker, Steven V.; Silva, Steve M.; Smith, Devin E.; Su, Yin-Fong; Toth, James J.; Wiberg, John D.; Yu, Xiao-Ying; Zuljevic, Nino

    2009-05-11

    This report summarizes results from pulse jet mixing (PJM) tests with noncohesive solids in Newtonian liquid conducted during FY 2007 and 2008 to support the design of mixing systems for the Hanford Waste Treatment and Immobilization Plant (WTP). Tests were conducted at three geometric scales using noncohesive simulants. The test data were used to independently develop mixing models that can be used to predict full-scale WTP vessel performance and to rate current WTP mixing system designs against two specific performance requirements. One requirement is to ensure that all solids have been disturbed during the mixing action, which is important to release gas from the solids. The second requirement is to maintain a suspended solids concentration below 20 weight percent at the pump inlet. The models predict the height to which solids will be lifted by the PJM action, and the minimum velocity needed to ensure all solids have been lifted from the floor. From the cloud height estimate we can calculate the concentration of solids at the pump inlet. The velocity needed to lift the solids is slightly more demanding than "disturbing" the solids, and is used as a surrogate for this metric. We applied the models to assess WTP mixing vessel performance with respect to the two perform¬ance requirements. Each mixing vessel was evaluated against these two criteria for two defined waste conditions. One of the wastes was defined by design limits and one was derived from Hanford waste characterization reports. The assessment predicts that three vessel types will satisfy the design criteria for all conditions evaluated. Seven vessel types will not satisfy the performance criteria used for any of the conditions evaluated. The remaining three vessel types provide varying assessments when the different particle characteristics are evaluated. The assessment predicts that three vessel types will satisfy the design criteria for all conditions evaluated. Seven vessel types will not satisfy the performance criteria used for any of the conditions evaluated. The remaining three vessel types provide varying assessments when the different particle characteristics are evaluated. The HLP-022 vessel was also evaluated using 12 m/s pulse jet velocity with 6-in. nozzles, and this design also did not satisfy the criteria for all of the conditions evaluated.

  11. Irradiation Test of Advanced PWR Fuel in Fuel Test Loop at HANARO

    SciTech Connect (OSTI)

    Yang, Yong Sik; Bang, Je Geon; Kim, Sun Ki; Song, Kun Woo; Park, Su Ki; Seo, Chul Gyo

    2007-07-01

    A new fuel test loop has been constructed in the research reactor HANARO at KAERI. The main objective of the FTL (Fuel Test Loop) is an irradiation test of a newly developed LWR fuel under PWR or Candu simulated conditions. The first test rod will be loaded within 2007 and its irradiation test will be continued until a rod average their of 62 MWd/kgU. A total of five test rods can be loaded into the IPS (In-Pile Section) and fuel centerline temperature, rod internal pressure and fuel stack elongation can be measured by an on-line real time system. A newly developed advanced PWR fuel which consists of a HANA{sup TM} alloy cladding and a large grain UO{sub 2} pellet was selected as the first test fuel in the FTL. The fuel cladding, the HANA{sup TM} alloy, is an Nb containing Zirconium alloy that has shown better corrosion and creep resistance properties than the current Zircaloy-4 cladding. A total of six types of HANA{sup TM} alloy were developed and two or three of these candidate alloys will be used as test rod cladding, which have shown a superior performance to the others. A large-grain UO{sub 2} pellet has a 14{approx}16 micron 2D diameter grain size for a reduction of a fission gas release at a high burnup. In this paper, characteristics of the FTL and IPS are introduced and the expected operation and irradiation conditions are summarized for the test periods. Also the preliminary fuel performance analysis results, such as the cladding oxide thickness, fission gas release and rod internal pressure, are evaluated from the test rod safety analysis aspects. (authors)

  12. Duct Leakage Repeatability Testing

    SciTech Connect (OSTI)

    Walker, Iain; Sherman, Max

    2014-08-01

    The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the two duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.

  13. Micromachine friction test apparatus

    DOE Patents [OSTI]

    deBoer, Maarten P. (Albuquerque, NM); Redmond, James M. (Albuquerque, NM); Michalske, Terry A. (Cedar Crest, NM)

    2002-01-01

    A microelectromechanical (MEM) friction test apparatus is disclosed for determining static or dynamic friction in MEM devices. The friction test apparatus, formed by surface micromachining, is based on a friction pad supported at one end of a cantilevered beam, with the friction pad overlying a contact pad formed on the substrate. A first electrostatic actuator can be used to bring a lower surface of the friction pad into contact with an upper surface of the contact pad with a controlled and adjustable force of contact. A second electrostatic actuator can then be used to bend the cantilevered beam, thereby shortening its length and generating a relative motion between the two contacting surfaces. The displacement of the cantilevered beam can be measured optically and used to determine the static or dynamic friction, including frictional losses and the coefficient of friction between the surfaces. The test apparatus can also be used to assess the reliability of rubbing surfaces in MEM devices by producing and measuring wear of those surfaces. Finally, the friction test apparatus, which is small in size, can be used as an in situ process quality tool for improving the fabrication of MEM devices.

  14. TEAM PROJECT: USER TESTING

    E-Print Network [OSTI]

    TEAM PROJECT: USER TESTING Due: Wed April 21 (section 2) Thu April 22 (section 1) Now that you have: usability inspection, Neilsen's heuristic evaluation, pluralistic walk through, or GOMS analysis (without part of your project. You might consider a joint session with another team! Format: 3-4 page report

  15. Audiometry (hearing test)

    Broader source: Energy.gov [DOE]

    The audiogram is an evaluation of how well an individual can hear. Sounds are presented to the individual through earphones during the test. These sounds are presented at different levels of frequency and intensity. The human ear responds to the frequency or pitch of a sound and the intensity or loudness of the sound.

  16. Bell Tests for Histories

    E-Print Network [OSTI]

    Jodan Cotler; Frank Wilczek

    2015-03-22

    We describe a procedure to create entangled history states and measurements that would enable one to check for temporal entanglement. The checks take the form of inequalities among observable quantities. They are similar in spirit, but different in detail, to Bell tests for ordinary entanglement.

  17. SMVCIR Dimensionality Test 

    E-Print Network [OSTI]

    Lindsey, Charles D.

    2011-08-08

    : : 134 13 Ex. 5.C.1, Tests for d, n = 5000 : : : : : : : : : : : : : : : : : : : : : 135 14 Output: SMVCIR D1-D4 Correlation : : : : : : : : : : : : : : : : : : 135 15 Output: SMVCIR Eigenvectors : : : : : : : : : : : : : : : : : : : : : 137 16 d = 0..., Normal : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 149 17 d = 0, T10 : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 149 18 d = 0, Standardized Exponential(1) : : : : : : : : : : : : : : : : : : : 150 19 d = 1...

  18. Copyright (c) Cem Kaner, Automated Testing. 1 Software Test Automation:Software Test Automation

    E-Print Network [OSTI]

    Copyright (c) Cem Kaner, Automated Testing. 1 Software Test Automation:Software Test Automation: A RealA Real--World ProblemWorld Problem Cem Kaner, Ph.D., J.D. #12;Copyright (c) Cem Kaner, Automated Testing. 2 This TalkThis Talk The most widely used class of automated testing tools leads senior software

  19. A test for second order stationarity of a time series based on the Discrete Fourier Transform -Technical report

    E-Print Network [OSTI]

    Subba Rao, Suhasini

    A test for second order stationarity of a time series based on the Discrete Fourier Transform stationary. Exploiting this important property, we construct a Portmanteau type test statistic for testing stationarity of the time series. It is shown that under the null of stationarity, the test statistic has

  20. Hydrogen in Type Ic Supernovae?

    E-Print Network [OSTI]

    David Branch; David J. Jeffery; Timothy R. Young; E. Baron

    2006-05-09

    By definition, a Type Ic supernova (SN Ic) does not have conspicuous lines of hydrogen or helium in its optical spectrum. SNe Ic usually are modelled in terms of the gravitational collapse of bare carbon-oxygen cores. We consider the possibility that the spectra of ordinary (SN 1994I-like) SNe Ic have been misinterpreted, and that SNe Ic eject hydrogen. An absorption feature usually attributed to a blend of Si II 6355 and C II 6580 may be produced by H-alpha. If SN 1994I-like SNe Ic eject hydrogen, the possibility that hypernova (SN 1998bw-like) SNe Ic, some of which are associated with gamma-ray bursts, also eject hydrogen should be considered. The implications of hydrogen for SN Ic progenitors and explosion models are briefly discussed.

  1. Laser-Based Nondestructive Testing

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Research Projects Laser-Based Nondestructive Testing High speed, non-contact NDT for bridging the gap between traditional nondestructive testing and embedded structural health...

  2. SPECTR System Operational Test Report

    SciTech Connect (OSTI)

    W.H. Landman Jr.

    2011-08-01

    This report overviews installation of the Small Pressure Cycling Test Rig (SPECTR) and documents the system operational testing performed to demonstrate that it meets the requirements for operations. The system operational testing involved operation of the furnace system to the design conditions and demonstration of the test article gas supply system using a simulated test article. The furnace and test article systems were demonstrated to meet the design requirements for the Next Generation Nuclear Plant. Therefore, the system is deemed acceptable and is ready for actual test article testing.

  3. Hanford Tank Farms Waste Certification Flow Loop Test Plan

    SciTech Connect (OSTI)

    Bamberger, Judith A.; Meyer, Perry A.; Scott, Paul A.; Adkins, Harold E.; Wells, Beric E.; Blanchard, Jeremy; Denslow, Kayte M.; Greenwood, Margaret S.; Morgen, Gerald P.; Burns, Carolyn A.; Bontha, Jagannadha R.

    2010-01-01

    A future requirement of Hanford Tank Farm operations will involve transfer of wastes from double shell tanks to the Waste Treatment Plant. As the U.S. Department of Energy contractor for Tank Farm Operations, Washington River Protection Solutions anticipates the need to certify that waste transfers comply with contractual requirements. This test plan describes the approach for evaluating several instruments that have potential to detect the onset of flow stratification and critical suspension velocity. The testing will be conducted in an existing pipe loop in Pacific Northwest National Laboratory’s facility that is being modified to accommodate the testing of instruments over a range of simulated waste properties and flow conditions. The testing phases, test matrix and types of simulants needed and the range of testing conditions required to evaluate the instruments are described

  4. Test probe for surface mounted leadless chip carrier

    DOE Patents [OSTI]

    Meyer, Kerry L. (Raytown, MO); Topolewski, John (Lenexa, KS)

    1989-05-23

    A test probe for a surface mounted leadless chip carrier is disclosed. The probed includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe.

  5. Test-aware Combinatorial Interaction Testing Cemal Yilmaz

    E-Print Network [OSTI]

    Yanikoglu, Berrin

    a configuration model that defines the valid configuration space for the software under test. This model typicallyTest-aware Combinatorial Interaction Testing Cemal Yilmaz Faculty of Engineering and Natural interaction testing (CIT) approaches system- atically sample a given configuration space and select a set

  6. Structured Testing: A Testing Methodology Using the Cyclomatic Complexity Metric

    E-Print Network [OSTI]

    Riabov, Vladimir V.

    The purpose of this document is to describe the structured testing methodology for software testing, also uses the control flow structure of software to establish path cover- age criteria. The resultant testCabe, object oriented, software development, software diagnostic, software metrics, software testing

  7. SOFTWARE TESTING, VERIFICATION AND RELIABILITY Softw. Test. Verif. Reliab. (2014)

    E-Print Network [OSTI]

    2014-01-01

    SOFTWARE TESTING, VERIFICATION AND RELIABILITY Softw. Test. Verif. Reliab. (2014) Published online. INTRODUCTION As software evolves, engineers regression test it to validate new features and detect whether new in Wiley Online Library (wileyonlinelibrary.com). DOI: 10.1002/stvr.1562 Directed test suite augmentation

  8. Test Access Mechanism Optimization, Test Scheduling, and Tester Data Volume

    E-Print Network [OSTI]

    Chakrabarty, Krishnendu

    Test Access Mechanism Optimization, Test Scheduling, and Tester Data Volume Reduction for System Marinissen, Senior Member, IEEE Abstract--We describe an integrated framework for system-on-chip (SOC) test automation. Our framework is based on a new test access mechanism (TAM) architecture consisting of flexible

  9. INVERSE-SQUARE LAW TESTS 1 TESTS OF THE GRAVITATIONAL

    E-Print Network [OSTI]

    Washington at Seattle, University of - Department of Physics, Electroweak Interaction Research Group

    INVERSE-SQUARE LAW TESTS 1 TESTS OF THE GRAVITATIONAL INVERSE-SQUARE LAW E.G.Adelberger, B-1560 KEYWORDS: gravitation, experimental tests of inverse-square law, quantum gravity, extra dimensions ABSTRACT: We review recent experimental tests of the gravitational inverse-square law, and the wide variety

  10. Measuring Test Case Similarity to Support Test Suite Understanding

    E-Print Network [OSTI]

    Zaidman, Andy

    Measuring Test Case Similarity to Support Test Suite Understanding Michaela Greiler, Arie van.e.zaidman}@tudelft.nl Abstract. In order to support test suite understanding, we investigate whether we can automatically derive relations between test cases. In par- ticular, we search for trace-based similarities between (high

  11. Sparkr Blade Test Centre Static tests of wind turbine blades

    E-Print Network [OSTI]

    Sparkær Blade Test Centre Static tests of wind turbine blades Static blade tests are performed down- and up-wind direction, and in the rotor thrust direction and opposite to that, respectively-4000 Roskilde Denmark www.risoe.dk Wind Energy Department Sparkær Blade test Centre vea@risoe.dk Tel

  12. Test factoring with amock: generating readable unit tests from system tests

    E-Print Network [OSTI]

    Glasser, David Samuel

    2007-01-01

    Automated unit tests are essential for the construction of reliable software, but writing them can be tedious. If the goal of test generation is to create a lasting unit test suite (and not just to optimize execution of ...

  13. Soil Testing Lab 

    E-Print Network [OSTI]

    Unknown

    2011-08-17

    Panels To enhance apparent thermal conductivity we have chosen to use aluminium fins under the form of honeycombs to ensure efficient heat conduction and good PCM incorporation. Commercial honeycomb panels were provided by the SMCI Company.... Honeycombs were 2 cm deep, and after being carefully filled covered with a 1 mm thick aluminium sheet (Figure 2) stuck on the honeycomb tips. Test samples with 15 cm x 15 cm dimension were realized together with a box of identical volume filled with water...

  14. Tests of CPT

    E-Print Network [OSTI]

    Shmuel Nussinov

    2009-07-17

    The ongoing experimental efforts in the high energy and high precision communities keep providing evidence for CPT, a fundamental symmetry holding in any local Lorentz invariant theory. We suggest possible interconnections between different CPT violating parameters. Specifically, the very precise test of CPT in the $K^0-\\bar K^0$ system suggests--though definitely does not imply--that CPT violations in other observable parameters (mass, width, charge, magnetic moments, etc.) are much smaller than the directly measured bounds.

  15. Alfalfa Seed Testing

    E-Print Network [OSTI]

    Ball, O. M. (Oscar Melville)

    1905-01-01

    ....................................... Curled Dock 9 .................... Seeds Sometin~es Used As Adultera~lts 9 Bur Clover ....................................... 10 Sweet Clover ....................................... 10 ............................... Samples Tested for Purity I I... development during the past year or two of the use of falfa as a forage crop makes the matter of purity of the seed to be kwn of peculiar importance to the planter. Alfalfa seed, like those clover, timothy and other similar forage plants, are very small...

  16. Parameter estimation with Sandage-Loeb test

    E-Print Network [OSTI]

    Jia-Jia Geng; Jing-Fei Zhang; Xin Zhang

    2014-11-28

    The Sandage-Loeb (SL) test directly measures the expansion rate of the universe in the redshift range of $2\\lesssim z\\lesssim 5$ by detecting redshift drift in the spectra of Lyman-$\\alpha$ forest of distant quasars. We discuss the impact of the future SL test data on parameter estimation for the $\\Lambda$CDM, the $w$CDM, and the $w_0w_a$CDM models. To avoid the potential inconsistency with other observational data, we take the best-fitting dark energy model constrained by the current observations as the fiducial model to produce 30 mock SL test data. The SL test data provide an important supplement to the other dark energy probes, since they are extremely helpful in breaking the existing parameter degeneracies. We show that the strong degeneracy between $\\Omega_m$ and $H_0$ in all the three dark energy models is well broken by the SL test. Compared to the current combined data of type Ia supernovae, baryon acoustic oscillation, cosmic microwave background, and Hubble constant, the 30-yr observation of SL test could improve the constraints on $\\Omega_m$ and $H_0$ by more than 60\\% for all the three models. But the SL test can only moderately improve the constraint on the equation of state of dark energy. We show that a 30-yr observation of SL test could help improve the constraint on constant $w$ by about 25\\%, and improve the constraints on $w_0$ and $w_a$ by about 20\\% and 15\\%, respectively. We also quantify the constraining power of the SL test in the future high-precision joint geometric constraints on dark energy. The mock future supernova and baryon acoustic oscillation data are simulated based on the space-based project JDEM. We find that the 30-yr observation of SL test would help improve the measurement precision of $\\Omega_m$, $H_0$, and $w_a$ by more than 70\\%, 20\\%, and 60\\%, respectively, for the $w_0w_a$CDM model.

  17. Parameter estimation with Sandage-Loeb test

    SciTech Connect (OSTI)

    Geng, Jia-Jia; Zhang, Jing-Fei; Zhang, Xin E-mail: jfzhang@mail.neu.edu.cn

    2014-12-01

    The Sandage-Loeb (SL) test directly measures the expansion rate of the universe in the redshift range of 2 ?< z ?< 5 by detecting redshift drift in the spectra of Lyman-? forest of distant quasars. We discuss the impact of the future SL test data on parameter estimation for the ?CDM, the wCDM, and the w{sub 0}w{sub a}CDM models. To avoid the potential inconsistency with other observational data, we take the best-fitting dark energy model constrained by the current observations as the fiducial model to produce 30 mock SL test data. The SL test data provide an important supplement to the other dark energy probes, since they are extremely helpful in breaking the existing parameter degeneracies. We show that the strong degeneracy between ?{sub m} and H{sub 0} in all the three dark energy models is well broken by the SL test. Compared to the current combined data of type Ia supernovae, baryon acoustic oscillation, cosmic microwave background, and Hubble constant, the 30-yr observation of SL test could improve the constraints on ?{sub m} and H{sub 0} by more than 60% for all the three models. But the SL test can only moderately improve the constraint on the equation of state of dark energy. We show that a 30-yr observation of SL test could help improve the constraint on constant w by about 25%, and improve the constraints on w{sub 0} and w{sub a} by about 20% and 15%, respectively. We also quantify the constraining power of the SL test in the future high-precision joint geometric constraints on dark energy. The mock future supernova and baryon acoustic oscillation data are simulated based on the space-based project JDEM. We find that the 30-yr observation of SL test would help improve the measurement precision of ?{sub m}, H{sub 0}, and w{sub a} by more than 70%, 20%, and 60%, respectively, for the w{sub 0}w{sub a}CDM model.

  18. Archive Reference Buildings by Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  19. Higher order integral stark-type conjectures

    E-Print Network [OSTI]

    Emmons, Caleb J.

    2006-01-01

    D . Popescu. Rubin's integral refinement of the abelianS A N DIEGO Higher Order Integral Stark-Type Conjectures ADISSERTATION Higher Order Integral Stark-Type Conjectures by

  20. New approaches for modeling type Ia supernovae

    E-Print Network [OSTI]

    Zingale, Michael; Almgren, Ann S.; Bell, John B.; Day, Marcus S.; Rendleman, Charles A.; Woosley, Stan

    2007-01-01

    ich and J. Stein. On the thermonuclear runaway in Type IaSmall-Scale Stability of Thermonuclear Flames o in Type IaS. E. Woosley. The thermonuclear explosion of chandrasekhar

  1. Archive Reference Buildings by Building Type: Supermarket

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  2. MULTIVARIATE OUTLYINGNESS FUNCTIONS MAHALANOBIS TYPE OUTLYINGNESS FUNCTIONS

    E-Print Network [OSTI]

    Serfling, Robert

    OUTLINE MULTIVARIATE OUTLYINGNESS FUNCTIONS MAHALANOBIS TYPE OUTLYINGNESS FUNCTIONS ADDITION MULTIVARIATE OUTLYINGNESS FUNCTIONS MAHALANOBIS TYPE OUTLYINGNESS FUNCTIONS ADDITION AND REPLACEMENT BREAKDOWN Criterion Robert Serfling NONPARAMETRIC OUTLIER IDENTIFICATION #12;OUTLINE MULTIVARIATE OUTLYINGNESS

  3. Ideal bandpasses for type Ia supernova cosmology

    E-Print Network [OSTI]

    Davis, Tamara M.; Schmidt, Brian P.; Kim, Alex G.

    2005-01-01

    diversity of type Ia Supernovae, in preparation. Kim, A.error in measurements of supernovae depends on a periodicABSTRACT To use type Ia supernovae as standard candles for

  4. 2015 Soil Testing Form -Commercial Plant Tissue Test Instructions

    E-Print Network [OSTI]

    New Hampshire, University of

    TOTAL COST: If you have recently applied fertilizer, lime or wood ash, please specify the type, date

  5. Rates and progenitors of type Ia supernovae

    E-Print Network [OSTI]

    Wood-Vasey, William Michael

    2004-01-01

    Supernovae . . . . . . . . . . . . . . . . . . . .Supernovae Found 5.1 Introduction . . . . . . . . . . . .1.2 Non-Type Ia Supernovae . . . . . . . . . . . . . . . 1.3

  6. Crystal of GTP Cyclohydrolase Type IB

    DOE Patents [OSTI]

    Swairjo, Manal A.; Iwata-Reuyl, Dirk; de Crecy-Lagard, Valerie

    2012-12-11

    This invention relates to a novel, bacterial GTP Cyclohydrolase Type IB enzyme, and the crystal structure thereof.

  7. The cone penetrometer test 

    E-Print Network [OSTI]

    Miran, Jerome

    1990-01-01

    for the data (Fig. 3. 1). These procedures are described below; one exists for the subtracting cone and one for the tension cone. 3. 1. 2 Subtracting Penetrometer Tip The 2 load cells in this type of penetrometer tip are calibrated simultaneously by loading.... 1. 2 Cone Resistance qr 5. 1. 3 Friction Resistance j, 5. 1. 4 Friction Ratio Rr 5. 2 Data Presentation and Report 5. 2. 1 Data Presentation 5. 2. 2 Report 5. 3 Importante Characteristics of the q, Profile . . . 31 33 34 34 34 36 37 5...

  8. Testing the CMB Data for Systematic Effects

    E-Print Network [OSTI]

    Griffiths, L M; Griffiths, Louise M.; Lineweaver, Charles H.

    2004-01-01

    Under the assumption that the concordance Lambda-cold dark matter (CDM) model is the correct model, we test the cosmic microwave background (CMB) anisotropy data for systematic effects by examining the band pass temperature residuals with respect to this model. Residuals are analysed as a function of angular scale l, galactic latitude, frequency, calibration source, instrument type and several other variables that may be associated with potential systematic effects. Our main result is that we find no significant systematic errors associated with these variables. However, we do find marginal evidence for a trend associated with galactic latitude indicative of galactic contamination.

  9. Fusion Test Facilities John Sheffield

    E-Print Network [OSTI]

    Fusion Test Facilities John Sheffield ISSE - University of Tennessee FPA meeting Livermore December Stambaugh, and their colleagues #12;Destructive Testing · It is common practice to test engineered components to destruction prior to deployment of a system e.g., - Automobile crash tests - Airplane wing

  10. Hydroshear Simulation Lab Test 2

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Bauer, Steve

    2014-08-01

    This data file is for test 2. In this test a sample of granite with a pre cut (man made fracture) is confined, heated and differential stress is applied. max temperature in this this system development test is 95C. test details on the spreadsheets--note thta there are 2 spreadsheets

  11. Online Test Proctoring Request Procedures

    E-Print Network [OSTI]

    Stuart, Steven J.

    Online Test Proctoring Request Procedures #12;Documentation last updated: Friday, January 17, 2014 Page | 2 of 10 Online Test Proctoring Request Form Procedures Contents Test Proctoring Center (TPC............................................................................................................................... 10 #12;Documentation last updated: Friday, January 17, 2014 Page | 3 of 10 Test Proctoring Center

  12. CERTS Microgrid Laboratory Test Bed

    E-Print Network [OSTI]

    Lasseter, R. H.

    2010-01-01

    design and testing of power converters and direct-drive permanent magnet generator technology for wind

  13. Hydroshear Simulation Lab Test 2

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Bauer, Steve

    This data file is for test 2. In this test a sample of granite with a pre cut (man made fracture) is confined, heated and differential stress is applied. max temperature in this this system development test is 95C. test details on the spreadsheets--note thta there are 2 spreadsheets

  14. Placement Testing with Justin Gray

    E-Print Network [OSTI]

    Placement Testing with LON-CAPA Justin Gray Dept. of Mathematics SFU #12;Problem Develop reliable placement tests for students who wish to challenge prerequisites for calculus (Calculus Readiness Test) and other quantitative courses (Q Placement Test). #12;Stages Selecting an assessment system Developing

  15. Advanced Vehicle Testing and Evaluation

    SciTech Connect (OSTI)

    Garetson, Thomas

    2013-03-31

    The objective of the United States (U.S.) Department of Energy?s (DOEs) Advanced Vehicle Testing and Evaluation (AVTE) project was to provide test and evaluation services for advanced technology vehicles, to establish a performance baseline, to determine vehicle reliability, and to evaluate vehicle operating costs in fleet operations. Vehicles tested include light and medium-duty vehicles in conventional, hybrid, and all-electric configurations using conventional and alternative fuels, including hydrogen in internal combustion engines. Vehicles were tested on closed tracks and chassis dynamometers, as well as operated on public roads, in fleet operations, and over prescribed routes. All testing was controlled by procedures developed specifically to support such testing. Testing and evaluations were conducted in the following phases: ? Development of test procedures, which established testing procedures; ? Baseline performance testing, which established a performance baseline; ? Accelerated reliability testing, which determined vehicle reliability; ? Fleet testing, used to evaluate vehicle economics in fleet operation, and ? End of test performance evaluation. Test results are reported by two means and posted by Idaho National Laboratory (INL) to their website: quarterly progress reports, used to document work in progress; and final test reports. This final report documents work conducted for the entirety of the contract by the Clarity Group, Inc., doing business as ECOtality North America (ECOtality). The contract was performed from 1 October 2005 through 31 March 2013. There were 113 light-duty on-road (95), off-road (3) and low speed (15) vehicles tested.

  16. Type Ia Supernova Carbon Footprints

    E-Print Network [OSTI]

    Thomas, R C; Aragon, C; Antilogus, P; Bailey, S; Baltay, C; Bongard, S; Buton, C; Canto, A; Childress, M; Chotard, N; Copin, Y; Fakhouri, H K; Gangler, E; Hsiao, E Y; Kerschhaggl, M; Kowalski, M; Loken, S; Nugent, P; Paech, K; Pain, R; Pecontal, E; Pereira, R; Perlmutter, S; Rabinowitz, D; Rigault, M; Rubin, D; Runge, K; Scalzo, R; Smadja, G; Tao, C; Weaver, B A; Wu, C; Brown, P J; Milne, P A

    2011-01-01

    We present convincing evidence of unburned carbon at photospheric velocities in new observations of 5 Type Ia supernovae (SNe Ia) obtained by the Nearby Supernova Factory. These SNe are identified by examining 346 spectra from 124 SNe obtained before +2.5 d relative to maximum. Detections are based on the presence of relatively strong C II 6580 absorption "notches" in multiple spectra of each SN, aided by automated fitting with the SYNAPPS code. Four of the 5 SNe in question are otherwise spectroscopically unremarkable, with ions and ejection velocities typical of SNe Ia, but spectra of the fifth exhibits high-velocity (v > 20,000 km/s) Si II and Ca II features. On the other hand, the light curve properties are preferentially grouped, strongly suggesting a connection between carbon-positivity and broad band light curve/color behavior: Three of the 5 have relatively narrow light curves but also blue colors, and a fourth may be a dust-reddened member of this family. Accounting for signal-to-noise and phase, we ...

  17. Nucleosynthesis in Type Ia Supernovae

    E-Print Network [OSTI]

    K. Nomoto; K. Iwamoto; N. Nakasato; F. -K. Thielemann; F. Brachwitz; T. Tsujimoto; Y. Kubo; N. Kishimoto

    1997-06-03

    Among the major uncertainties involved in the Chandrasekhar mass models for Type Ia supernovae are the companion star of the accreting white dwarf (or the accretion rate that determines the carbon ignition density) and the flame speed after ignition. We present nucleosynthesis results from relatively slow deflagration (1.5 - 3 % of the sound speed) to constrain the rate of accretion from the companion star. Because of electron capture, a significant amount of neutron-rich species such as ^{54}Cr, ^{50}Ti, ^{58}Fe, ^{62}Ni, etc. are synthesized in the central region. To avoid the too large ratios of ^{54}Cr/^{56}Fe and ^{50}Ti/^{56}Fe, the central density of the white dwarf at thermonuclear runaway must be as low as \\ltsim 2 \\e9 \\gmc. Such a low central density can be realized by the accretion as fast as $\\dot M \\gtsim 1 \\times 10^{-7} M_\\odot yr^{-1}$. These rapidly accreting white dwarfs might correspond to the super-soft X-ray sources.

  18. Implementation Techniques for Inductive Types in Plastic ?

    E-Print Network [OSTI]

    Luo, Zhaohui

    Implementation Techniques for Inductive Types in Plastic ? Paul Callaghan and Zhaohui Luo://www.dur.ac.uk/CARG fP.C.Callaghan, Zhaohui.Luog@durham.ac.uk Abstract. In the context of Plastic, a proof assistant the reduction mechanisms of Plastic, and briefly considers optimisations for inductive types. Key words: type

  19. Challenges in Type Systems Research Martin Odersky

    E-Print Network [OSTI]

    Odersky, Martin

    Challenges in Type Systems Research Martin Odersky University of Karlsruhe ______________________________________________________________________ Type systems are one backbones of programming language design and implementatio* *n. Current research. ______________________________________________________________________ Over the last 20 years, type systems have developed into a backbone of pro- gramming language research

  20. Semicontinuous Sized Types and Termination Andreas Abel #

    E-Print Network [OSTI]

    Abel, Andreas

    , and classical applications are total correctness and termination of partial evaluation. In languagesSemi­continuous Sized Types and Termination Andreas Abel # Institut für Informatik Ludwig to termination uses sized types: an ordinal bound for the size of a data structure is stored in its type

  1. VERSION CORRIGE CORRECTED VERSION The influence of kinetic test type on the geochemical response of low

    E-Print Network [OSTI]

    Aubertin, Michel

    Industrial NSERC Polytechnique-UQAT Chair on Environment and Mine Waste Management, UQAT, 445 University blvd on Environment and Mine Waste Management, École Polytechnique, C.P. 6079, Succ. Centre-Ville, Montréal, Québec, Rouyn-Noranda, Québec, Canada, J9X 5E4. Michel Aubertin Industrial NSERC Polytechnique-UQAT Chair

  2. Preparation of carbide-type, advanced LMFBR fuel pellets for irradiation testing

    SciTech Connect (OSTI)

    Gutierrez, R.L.; Herbst, R.J.

    1980-06-01

    A carbothermic reduction process was established to fabricate single- and two-phase uranium-plutonium carbide fuel on a production basis. Sintering temperatures of 1550 and 1800/sup 0/C were used to prepare fuel densities of 98, 87, and 81% of theoretical.

  3. Analysis of well test data influenced by multiple reservoir boundaries using pressure derivative type curves 

    E-Print Network [OSTI]

    Buzarde, Charles Brett

    1991-01-01

    Well No-Flow Boundary Image Well Figure 2. 2 Real Well and Image Well Pressure Drwadown Patterns After an Extended Flow Period. Real well ~ L rw I m age w e I 1 L ~ rw Figure 2. 3 Single Linear No-flow Barrier Image Well Configuration 22 Apr.... 1 At early times the value of tD will be large while our value of tDL will be small (because rw2 ?L2) Therefore at early times the exponent terms in Eq. 3. 1 have the following values -I p(4t ) -I and exp( ? ) ~ 0 tDL This is the middle time...

  4. Laboratory Tests Indicate Conditions that Could Potentially Impact Certain Type of HEPA Filter Performance

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankADVANCED MANUFACTURING OFFICE INDUSTRIALU.S. DepartmentJeanKeyLANLLG:KAHUKULaboratory2 August 2013

  5. Micro-tensile testing system

    DOE Patents [OSTI]

    Wenski, Edward G.

    2006-01-10

    A micro-tensile testing system providing a stand-alone test platform for testing and reporting physical or engineering properties of test samples of materials having thicknesses of approximately between 0.002 inch and 0.030 inch, including, for example, LiGA engineered materials. The testing system is able to perform a variety of static, dynamic, and cyclic tests. The testing system includes a rigid frame and adjustable gripping supports to minimize measurement errors due to deflection or bending under load; serrated grips for securing the extremely small test sample; high-speed laser scan micrometers for obtaining accurate results; and test software for controlling the testing procedure and reporting results.

  6. Micro-tensile testing system

    DOE Patents [OSTI]

    Wenski, Edward G. (Lenexa, KS)

    2007-07-17

    A micro-tensile testing system providing a stand-alone test platform for testing and reporting physical or engineering properties of test samples of materials having thicknesses of approximately between 0.002 inch and 0.030 inch, including, for example, LiGA engineered materials. The testing system is able to perform a variety of static, dynamic, and cyclic tests. The testing system includes a rigid frame and adjustable gripping supports to minimize measurement errors due to deflection or bending under load; serrated grips for securing the extremely small test sample; high-speed laser scan micrometers for obtaining accurate results; and test software for controlling the testing procedure and reporting results.

  7. Micro-tensile testing system

    DOE Patents [OSTI]

    Wenski, Edward G. (Lenexa, KS)

    2007-08-21

    A micro-tensile testing system providing a stand-alone test platform for testing and reporting physical or engineering properties of test samples of materials having thicknesses of approximately between 0.002 inch and 0.030 inch, including, for example, LiGA engineered materials. The testing system is able to perform a variety of static, dynamic, and cyclic tests. The testing system includes a rigid frame and adjustable gripping supports to minimize measurement errors due to deflection or bending under load; serrated grips for securing the extremely small test sample; high-speed laser scan micrometers for obtaining accurate results; and test software for controlling the testing procedure and reporting results.

  8. Pompano subsea development -- Testing program

    SciTech Connect (OSTI)

    Nelson, R.; Berger, R.; Tyer, C.

    1996-12-31

    System reliability is essential for the economic success of any subsea oil and gas development. Testing programs can be developed to prove system reliability while still adhering to cost and schedule constraints. This paper describes a three-tiered equipment testing program that was employed for the Pompano Phase 2 subsea system. Program objectives, test descriptions, procedure development and test execution are discussed in detail. Lessons learned throughout the tests are also presented.

  9. CERTS Microgrid Laboratory Test Bed

    E-Print Network [OSTI]

    Lasseter, R. H.

    2010-01-01

    and direct-drive permanent magnet generator technology forsystem. The generator is liquid-cooled permanent magnet type

  10. Fire testing of bare uranium hexafluoride cylinders

    SciTech Connect (OSTI)

    Pryor, W.A. [PAI Corp., Oak Ridge, TN (United States)

    1991-12-31

    In 1965, the Oak Ridge Gaseous Diffusion Plant (ORGDP), now the K-25 Site, conducted a series of tests in which bare cylinders of uranium hexafluoride (UF{sub 6}) were exposed to engulfing oil fires for the US Atomic Energy Commission (AEC), now the US Department of Energy (DOE). The tests are described and the results, conclusions, and observations are presented. Two each of the following types of cylinders were tested: 3.5-in.-diam {times} 7.5-in.-long cylinders of Monel (Harshaw), 5.0-in.-diam {times} x 30-in.-long cylinders of Monel, and 8-in.-diam {times} 48-in.-long cylinders of nickel. The cylinders were filled approximately to the standard UF{sub 6} fill limits of 5, 55, and 250 lb, respectively, with a U-235 content of 0.22%. The 5-in.- and 8-in.-diam cylinders were tested individually with and without their metal valve covers. For the 3.5-in.-diam Harshaw cylinders and the 5.0-in.-diam cylinder without a valve cover, the valves failed and UF{sub 6} was released. The remaining 6 cylinders ruptured explosively in time intervals ranging from about 8.5 to 11 min.

  11. Fire testing of bare uranium hexafluoride cylinders

    SciTech Connect (OSTI)

    Pryor, W.A. [PAI Corp., Oak Rige, TN (United States)

    1991-12-31

    In 1965, the Oak Ridge Gaseous Diffusion Plant (ORGDP), now the K-25 Site, conducted a series of tests in which bare cylinders of uranium hexafluoride (UF{sub 6}) were exposed to engulfing oil fires for the US Atomic Energy Commission (AEC), now the US Department of Energy (DOE). The tests are described and the results, conclusions, and observations are presented. Two each of the following types of cylinders were tested: 3.5-in.-diam {times} 7.5-in.-long cylinders of Monel (Harshaw), 5.0-in.-diam {times} 30-in.-long cylinders of Monel, and 8-in.-diam {times} 48-in.-long cylinders of nickel. The cylinders were filled approximately to the standard UF{sub 6} fill limits of 5, 55, and 250 lb, respectively, with a U-235 content of 0.22%. The 5-in.- and 8-in.-diam cylinders were tested individually with and without their metal valve covers. For the 3.5-in.-diam Harshaw cylinders and the 5.0-in.-diam cylinder without a valve cover the valves failed and UF{sub 6} was released. The remaining cylinders ruptured explosively in time intervals ranging from about 8.5 to 11 min.

  12. Bomb tests attack the food chain

    SciTech Connect (OSTI)

    Ruff, T. )

    1990-03-01

    Ciguatera poisoning, the most common type of fish poisoning in the world, has become a major public health problem in some parts of the South Pacific. This area has always been the site of periodic outbreaks, especially after severe storms or natural disasters that damage core reefs. But since World War II it has become evident that military activities and major construction projects that wreak havoc on corals also lead to ciguatera outbreaks. Extraordinarily high rates of ciguatera poisoning have occurred on the small Pacific islands that have been used for nuclear tests and on the islands that host the military infrastructures and activities that accompany the tests. This is true for both the Marshall Islands near Bikini and Eniwetok, where U.S. tests took place, and in French Polynesia, in the area around Moruroa Atoll where the French government continues to test. Ciguatera poisoning has a disastrous effect on people who depend on fishing as a way of life and on fish as the major source of protein. 10 refs.

  13. Surveillance test interval optimization

    SciTech Connect (OSTI)

    Cepin, M.; Mavko, B. [Institut Jozef Stefan, Ljublijana (Slovenia)

    1995-12-31

    Technical specifications have been developed on the bases of deterministic analyses, engineering judgment, and expert opinion. This paper introduces our risk-based approach to surveillance test interval (STI) optimization. This approach consists of three main levels. The first level is the component level, which serves as a rough estimation of the optimal STI and can be calculated analytically by a differentiating equation for mean unavailability. The second and third levels give more representative results. They take into account the results of probabilistic risk assessment (PRA) calculated by a personal computer (PC) based code and are based on system unavailability at the system level and on core damage frequency at the plant level.

  14. Resonance test system

    DOE Patents [OSTI]

    Musial, Walter (Boulder, CO); White, Darris (Superior, CO)

    2011-05-31

    An apparatus (10) for applying at least one load to a specimen (12) according to one embodiment of the invention may comprise a mass (18). An actuator (20) mounted to the specimen (12) and operatively associated with the mass (18) moves the mass (18) along a linear displacement path (22) that is perpendicular to a longitudinal axis of the specimen (12). A control system (26) operatively associated with the actuator (20) operates the actuator (20) to reciprocate the mass (18) along the linear displacement path (22) at a reciprocating frequency, the reciprocating frequency being about equal to a resonance frequency of the specimen (12) in a test configuration.

  15. Reversal bending fatigue testing

    DOE Patents [OSTI]

    Wang, Jy-An John; Wang, Hong; Tan, Ting

    2014-10-21

    Embodiments for apparatuses for testing reversal bending fatigue in an elongated beam are disclosed. Embodiments are configured to be coupled to first and second end portions of the beam and to apply a bending moment to the beam and create a pure bending condition in an intermediate portion of the beam. Embodiments are further configured to cyclically alternate the direction of the bending moment applied to the beam such that the intermediate portion of the beam cyclically bends in opposite directions in a pure bending condition.

  16. Sculpt test problem analysis.

    SciTech Connect (OSTI)

    Sweetser, John David

    2013-10-01

    This report details Sculpt's implementation from a user's perspective. Sculpt is an automatic hexahedral mesh generation tool developed at Sandia National Labs by Steve Owen. 54 predetermined test cases are studied while varying the input parameters (Laplace iterations, optimization iterations, optimization threshold, number of processors) and measuring the quality of the resultant mesh. This information is used to determine the optimal input parameters to use for an unknown input geometry. The overall characteristics are covered in Chapter 1. The speci c details of every case are then given in Appendix A. Finally, example Sculpt inputs are given in B.1 and B.2.

  17. Test Circuit Service

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired Solar FuelTechnologyTel: Name: Rm. Tel:Test Circuit Service Network

  18. Test NIMROD Pictures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired Solar FuelTechnologyTel: Name: Rm. Tel:Test Circuit Service Network The

  19. Nuclear testing continues

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration wouldMass map shinesSolarNewsusceptometer under pressureNavy TurnsNuclearNuclear >testing

  20. High Volume Test Automation 1 High Volume Test AutomationHigh Volume Test Automation

    E-Print Network [OSTI]

    High Volume Test Automation 1 High Volume Test AutomationHigh Volume Test Automation Keynote Automation 2 AcknowledgementsAcknowledgements · Many of the ideas in this presentation were initially jointly developed with Doug Hoffman,as we developed a course on test automation architecture, and in the Los Altos

  1. High Temperature Evaluation of Tantalum Capacitors - Test 1

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Cieslewski, Grzegorz

    2014-09-28

    Tantalum capacitors can provide much higher capacitance at high-temperatures than the ceramic capacitors. This study evaluates selected tantalum capacitors at high temperatures to determine their suitability for you in geothermal field. This data set contains results of the first test where three different types of capacitors were evaluated at 260C.

  2. Design and Test of Tube & Shell Heat Exchangers for Potential

    E-Print Network [OSTI]

    of double-tube heat exchangers #12;Company Logo Experimental apparatus Metal Type Ti SUS304 Al Cu Al 15m AlDesign and Test of Tube & Shell Heat Exchangers for Potential OTEC Application Jeong-Tae Kwon1 exchanger #12;Company Logo Cross-Counter -1 heat exchanger Cross-Counter -2 heat exchanger Double tube heat

  3. The UC Davis Emerging Lithium Battery Test Project

    E-Print Network [OSTI]

    Burke, Andy; Miller, Marshall

    2009-01-01

    graphite/NiCoMn chemistry. In general, it is possible to design high power batteries (graphite/NiCoMn chemistry. In general, it seems possible to design high power batteries (Batteries tested -manufacturers, technology, and characteristics Manufacturer K2 EIG A123 Technology type Iron phosphate Iron phosphate Iron phosphate Iron Phosphate Graphite/

  4. High Temperature Evaluation of Tantalum Capacitors - Test 1

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Cieslewski, Grzegorz

    Tantalum capacitors can provide much higher capacitance at high-temperatures than the ceramic capacitors. This study evaluates selected tantalum capacitors at high temperatures to determine their suitability for you in geothermal field. This data set contains results of the first test where three different types of capacitors were evaluated at 260C.

  5. Activated carbon testing for the 200 area effluent treatment facility

    SciTech Connect (OSTI)

    Wagner, R.N.

    1997-01-17

    This report documents pilot and laboratory scale testing of activated carbon for use in the 200 Area Effluent Treatment Facility peroxide decomposer columns. Recommendations are made concerning column operating conditions and hardware design, the optimum type of carbon for use in the plant, and possible further studies.

  6. n-Linear Algebra of type II

    E-Print Network [OSTI]

    W. B. Vasantha Kandasamy; Florentin Smarandache

    2009-02-01

    This book is a continuation of the book n-linear algebra of type I and its applications. Most of the properties that could not be derived or defined for n-linear algebra of type I is made possible in this new structure: n-linear algebra of type II which is introduced in this book. In case of n-linear algebra of type II we are in a position to define linear functionals which is one of the marked difference between the n-vector spaces of type I and II. However all the applications mentioned in n-linear algebras of type I can be appropriately extended to n-linear algebras of type II. Another use of n-linear algebra (n-vector spaces) of type II is that when this structure is used in coding theory we can have different types of codes built over different finite fields whereas this is not possible in the case of n-vector spaces of type I. Finally in the case of n-vector spaces of type II, we can obtain n-eigen values from distinct fields; hence, the n-characteristic polynomials formed in them are in distinct different fields. An attractive feature of this book is that the authors have suggested 120 problems for the reader to pursue in order to understand this new notion. This book has three chapters. In the first chapter the notion of n-vector spaces of type II are introduced. This chapter gives over 50 theorems. Chapter two introduces the notion of n-inner product vector spaces of type II, n-bilinear forms and n-linear functionals. The final chapter suggests over a hundred problems. It is important that the reader is well-versed not only with linear algebra but also n-linear algebra of type I.

  7. Marginal evidence for cosmic acceleration from Type Ia supernovae

    E-Print Network [OSTI]

    Jeppe Trøst Nielsen; Alberto Guffanti; Subir Sarkar

    2015-06-09

    The "standard" model of cosmology is founded on the basis that the expansion rate of the universe is accelerating at present --- as was inferred originally from the Hubble diagram of Type Ia supernovae. There exists now a much bigger database of supernovae so we can perform rigorous statistical tests to check whether these "standardisable candles" indeed indicate cosmic acceleration. Taking account of the empirical procedure by which corrections are made to their absolute magnitudes to allow for the varying shape of the light curve and extinction by dust, we find, rather surprisingly, that the data are still quite consistent with a constant rate of expansion.

  8. Marginal evidence for cosmic acceleration from Type Ia supernovae

    E-Print Network [OSTI]

    Nielsen, Jeppe Trøst; Sarkar, Subir

    2015-01-01

    The `standard' model of cosmology is founded on the basis that the expansion rate of the universe is accelerating at present --- as was inferred originally from the Hubble diagram of Type Ia supernovae. There exists now a much bigger database of supernovae so we can perform rigorous statistical tests to check whether these `standardisable candles' indeed indicate cosmic acceleration. Taking account of the empirical procedure by which corrections are made to their absolute magnitudes to allow for the varying shape of the light curve and extinction by dust, we find, rather surprisingly, that the data are still quite consistent with a constant rate of expansion.

  9. Documentation and verification required for type A packaging use

    SciTech Connect (OSTI)

    O`Brien, J.H.

    1997-07-30

    This document furnishes knowledge and methods for verifying compliance with the U.S. Department of Transportation (DOT) packaging requirements for shipping Type A quantities of radioactive material. The primary emphasis is on the requirements identified in 49 CFR 173.415(a), which states, ``Each offeror of a Specification 7A package must maintain on file for at least one year after the shipment, and shall provide to DOT on request, complete documentation of tests and an engineering evaluation of comparative data showing that the construction methods, packaging design, and materials of construction comply with that specification.`` This guidance document uses a checklist to show compliance.

  10. TYPE A FISSILE PACKAGING FOR AIR TRANSPORT PROJECT OVERVIEW

    SciTech Connect (OSTI)

    Eberl, K.; Blanton, P.

    2013-10-11

    This paper presents the project status of the Model 9980, a new Type A fissile packaging for use in air transport. The Savannah River National Laboratory (SRNL) developed this new packaging to be a light weight (<150-lb), drum-style package and prepared a Safety Analysis for Packaging (SARP) for submission to the DOE/EM. The package design incorporates unique features and engineered materials specifically designed to minimize packaging weight and to be in compliance with 10CFR71 requirements. Prototypes were fabricated and tested to evaluate the design when subjected to Normal Conditions of Transport (NCT) and Hypothetical Accident Conditions (HAC). An overview of the design details, results of the regulatory testing, and lessons learned from the prototype fabrication for the 9980 will be presented.

  11. A new hydrodynamics code for Type Ia Supernovae

    E-Print Network [OSTI]

    Leung, S -C; Lin, L -M

    2015-01-01

    A two-dimensional hydrodynamics code for Type Ia supernovae (SNIa) simulations is presented. The code includes a fifth-order shock-capturing scheme WENO, detailed nuclear reaction network, flame-capturing scheme and sub-grid turbulence. For post-processing we have developed a tracer particle scheme to record the thermodynamical history of the fluid elements. We also present a one-dimensional radiative transfer code for computing observational signals. The code solves the Lagrangian hydrodynamics and moment-integrated radiative transfer equations. A local ionization scheme and composition dependent opacity are included. Various verification tests are presented, including standard benchmark tests in one and two dimensions. SNIa models using the pure turbulent deflagration model and the delayed-detonation transition model are studied. The results are consistent with those in the literature. We compute the detailed chemical evolution using the tracer particles' histories, and we construct corresponding bolometric...

  12. Psychrometric Testing Facility Restoration and Cooling Capacity Testing 

    E-Print Network [OSTI]

    Cline, Vincent E.

    2010-10-12

    The Psychrometric Testing Facility at the Riverside Energy Efficiency Laboratory at Texas AandM University has not been operational for several years. The goal of this project was to restore the testing facility to a fully ...

  13. Standard test method for creep-fatigue testing

    E-Print Network [OSTI]

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  14. Sandia Energy - Test Site Operations & Maintenance Safety

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Test Site Operations & Maintenance Safety Home Stationary Power Energy Conversion Efficiency Wind Energy SWiFT Facility & Testing Test Site Operations & Maintenance Safety Test...

  15. Comparing the host galaxies of type Ia, type II, and type Ibc supernovae

    SciTech Connect (OSTI)

    Shao, X.; Liang, Y. C.; Chen, X. Y.; Zhong, G. H.; Deng, L. C.; Zhang, B.; Shi, W. B.; Zhou, L. [Key Laboratory of Optical Astronomy, National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, Chaoyang District, Beijing 100012 (China); Dennefeld, M. [Institut d'Astrophysique de Paris, CNRS, and Universite P. et M. Curie, 98bis Bd Arago, F-75014 Paris (France); Hammer, F.; Flores, H., E-mail: xshao@bao.ac.cn, E-mail: ycliang@bao.ac.cn [GEPI, Observatoire de Paris-Meudon, F-92195 Meudon (France)

    2014-08-10

    We compare the host galaxies of 902 supernovae (SNe), including SNe Ia, SNe II, and SNe Ibc, which are selected by cross-matching the Asiago Supernova Catalog with the Sloan Digital Sky Survey (SDSS) Data Release 7. We selected an additional 213 galaxies by requiring the light fraction of spectral observations to be >15%, which could represent well the global properties of the galaxies. Among these 213 galaxies, 135 appear on the Baldwin-Phillips-Terlevich diagram, which allows us to compare the hosts in terms of whether they are star-forming (SF) galaxies, active galactic nuclei (AGNs; including composites, LINERs, and Seyfert 2s) or absorption-line galaxies (Absorps; i.e., their related emission lines are weak or non-existent). The diagrams related to the parameters D{sub n}(4000), H?{sub A}, stellar masses, star formation rates (SFRs), and specific SFRs for the SNe hosts show that almost all SNe II and most of the SNe Ibc occur in SF galaxies, which have a wide range of stellar masses and low D{sub n}(4000). The SNe Ia hosts as SF galaxies following similar trends. A significant fraction of SNe Ia occurs in AGNs and absorption-line galaxies, which are massive and have high D{sub n}(4000). The stellar population analysis from spectral synthesis fitting shows that the hosts of SNe II have a younger stellar population than hosts of SNe Ia. These results are compared with those of the 689 comparison galaxies where the SDSS fiber captures less than 15% of the total light. These comparison galaxies appear biased toward higher 12+log(O/H) (?0.1 dex) at a given stellar mass. Therefore, we believe the aperture effect should be kept in mind when the properties of the hosts for different types of SNe are discussed.

  16. STORAGE OPERATORS and -POSITIVE TYPES in TTR TYPE Karim NOUR 1

    E-Print Network [OSTI]

    Nour, Karim

    STORAGE OPERATORS and -POSITIVE TYPES in TTR TYPE SYSTEM Karim NOUR 1 LAMA - Equipe de Logique the notion of storage operator to simulate "call by value" in the "call by name" strategy. J.L. Krivine has for the storage operators in AF2 type system. This paper studies the -positive types (the universal second order

  17. Testing for Lead Poisoning Are we testing the right kids?

    E-Print Network [OSTI]

    Testing for Lead Poisoning Are we testing the right kids? City of Atlanta 2005 September 25, 2006September 25, 2006 Ambarish Vaidyanathan, MSEnvE Forrest Staley, MUP, MPHc #12;Objective To assess lead testing of children at high risk for lead poisoning in the city of Atlanta #12;Rationale · Childhood Lead

  18. SOFTWARE TESTING, VERIFICATION AND RELIABILITY Softw. Test. Verif. Reliab. (2014)

    E-Print Network [OSTI]

    2014-01-01

    June 2014; Accepted 8 August 2014 KEY WORDS: automated test case generation; function block diagram defined by the International Electrotechnical Commission (IEC). Industrial FBD testing relies mostly criteria defined by Jee et al. [1]. Given a unit FBD program, test requirements expressed in logical

  19. AEC PHOTOVOLTAIC TEST FACILITY FIRST YEAR TEST DATA James Krumsick

    E-Print Network [OSTI]

    Oregon, University of

    AEC PHOTOVOLTAIC TEST FACILITY ­ FIRST YEAR TEST DATA James Krumsick Alternative Energy Consortium@uoregon.edu ABSTRACT Alternative Energy Consortium's Photovoltaic test facility (AEC PV) came on line in August, 2004 is to evaluate different photovoltaic products and to monitor the performance of these products under different

  20. Methodology for testing metal detectors using variables test data

    SciTech Connect (OSTI)

    Spencer, D.D.; Murray, D.W.

    1993-08-01

    By extracting and analyzing measurement (variables) data from portal metal detectors whenever possible instead of the more typical ``alarm``/``no-alarm`` (attributes or binomial) data, we can be more informed about metal detector health with fewer tests. This testing methodology discussed in this report is an alternative to the typical binomial testing and in many ways is far superior.

  1. Solutions for Biomedical Testing SolutionsforBiomedicalTesting

    E-Print Network [OSTI]

    Sniadecki, Nathan J.

    . As technology evolves, researchers and manufacturers face the enduring task of delivering biomaterials.instron.com SolutionsforBiomedicalTesting DentalTesting Pages32 -33 Spine Testing Pages28 -31 Biom echanics & Kinesiology properties and performance across a vast spectrum of biomaterials and medical products. Instron has

  2. Film Coating Process Research and Characterization of TiN Coated Racetrack-type Ceramic Pipe

    E-Print Network [OSTI]

    Wang, Jie; Zhang, Bo; Wei, Wei; Fan, Le; Pei, Xiangtao; Hong, Yuanzhi; Wang, Yong

    2015-01-01

    TiN film was coated on the internal face of racetrack-type ceramic pipe by three different methods: radio-frequency sputtering, DC sputtering and DC magnetron sputtering. The deposition rates of TiN film under different coating methods were compared. According to the AFM, SEM, XPS test results,these properties were analyzed, such as TiN film roughness and surface morphology. At the same time, the deposition rates were studied under two types' cathode, Ti wires and Ti plate. According to the SEM test results, Ti plate cathode can improve the TiN/Ti film deposition rate obviously.

  3. Infrared source test

    SciTech Connect (OSTI)

    Ott, L.

    1994-11-15

    The purpose of the Infrared Source Test (IRST) is to demonstrate the ability to track a ground target with an infrared sensor from an airplane. The system is being developed within the Advance Technology Program`s Theater Missile Defense/Unmanned Aerial Vehicle (UAV) section. The IRST payload consists of an Amber Radiance 1 infrared camera system, a computer, a gimbaled mirror, and a hard disk. The processor is a custom R3000 CPU board made by Risq Modular Systems, Inc. for LLNL. The board has ethernet, SCSI, parallel I/O, and serial ports, a DMA channel, a video (frame buffer) interface, and eight MBytes of main memory. The real-time operating system VxWorks has been ported to the processor. The application code is written in C on a host SUN 4 UNIX workstation. The IRST is the result of a combined effort by physicists, electrical and mechanical engineers, and computer scientists.

  4. Accelerated Testing Validation

    SciTech Connect (OSTI)

    Mukundan, Rangachary; James, Greg; Davey, John; Langlois, David; Torraco, Dennis; Yoon, Wonseok; Weber, Adam Z; Borup, Rodney L.

    2011-07-01

    The DOE Fuel Cell technical team recommended ASTs were performed on 2 different MEAs (designated P5 and HD6) from Ballard Power Systems. These MEAs were also incorporated into stacks and operated in fuel cell bus modules that were either operated in the field (three P5 buses) in Hamburg, or on an Orange county transit authority drive cycle in the laboratory (HD6 bus module). Qualitative agreement was found in the degradation mechanisms and rates observed in the AST and in the field. The HD6 based MEAs exhibited lower voltage degradation rates (due to catalyst corrosion) and slower membrane degradation rates in the field as reflected by their superior performance in the high potential hold and open-circuit potential AST tests. The quantitative correlation of the degradation rates will have to take into account the various stressors in the field including temperature, relative humidity, start/stops and voltage cycles.

  5. Relay test program. Series 2 tests: Integral testing of relays and circuit breakers

    SciTech Connect (OSTI)

    Bandyopadhyay, K.K.; Kunkel, C.; Shteyngart, S. [Brookhaven National Lab., Upton, NY (United States)

    1994-02-01

    This report presents the results of a relay test program conducted by Brookhaven National Laboratory (BNL) under the sponsorship of the US Nuclear Regulatory Commission (NRC). The program is a continuation of an earlier test program the results of which were published in NUREG/CR-4867. The current program was carried out in two phases: electrical testing and vibration testing. The objective was primarily to focus on the electrical discontinuity or continuity of relays and circuit breaker tripping mechanisms subjected to electrical pulses and vibration loads. The electrical testing was conducted by KEMA-Powertest Company and the vibration testing was performed at Wyle Laboratories, Huntsville, Alabama. This report discusses the test procedures, presents the test data, includes an analysis of the data and provides recommendations regarding reliable relay testing.

  6. Voluntary Participation in Organizational Decision-Making: A Model and an Experimental Test 

    E-Print Network [OSTI]

    McMahon, Anne; Camilleri, Santo F

    2015-08-11

    -Type text/plain; charset=UTF-8 by Anne McMahon Stanford University and Santo F. Camilleri Michigan State University VOLUNTARY PARTICIPATION IN ORGANIZATIONAL DECISION-MAKING: A MODEL AND AN EXPERIMENTAL TEST* Technical Report No. 44 1972...

  7. DOT Specification 7A Type A packaging certification study: getting ready for July 1, 1985

    SciTech Connect (OSTI)

    Edling, D.A.

    1985-01-01

    The Department of Energy has funded Mound to revise the Type A Packaging Certification Study originally issued in June 1975. An updated document is necessary because, effective July 1, 1985, 49 CFR 173.412(b) requires that any Spec. 7A packaging designed, manufactured, or certified after that date must be certified according to the Type A packaging test given in 173.465. As a result, shippers of Spec. 7A packagings must test and analyze their packaging and prepare a certification document before July 1985 in order to continue uninterrupted operation. (It should be noted that existing Spec. 7A packages manufactured and certified prior to July 1, 1985, may be used as long as the packagings continue to meet the Spec. 7A requirements. However, a Type A packaging designed, manufactured, or certified after July 1, 1985, must meet the requirements of 49 CFR effective on July 1, 1985.) Mound will identify those Type A packagings commonly used by DOE contractors and will begin a testing and analysis program to determine which packagings meet the new Type A requirement. Those packagings certified as DOE Spec. 7A Type A packagings will be featured in a document for all of DOE to use. 5 tabs.

  8. Preface: The Dalmarnock Fire Tests 

    E-Print Network [OSTI]

    Torero, Jose L; Carvel, Ricky O

    2007-11-14

    Given the current state of the art, the vibrancy of the profession and existing data from numerous large scale tests, why are new large scale experiments like the Dalmarnock Tests important or, indeed, even necessary?

  9. Federal Substance Abuse Testing Program

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2014-01-30

    The Order establishes the requirements and responsibilities for the DOE Federal Substance Abuse Testing Program which covers drug and alcohol testing. Supersedes DOE O 3792.3 Chg 1.

  10. GUI Testing Using Computer Vision

    E-Print Network [OSTI]

    Chang, Tsung-Hsiang

    Testing a GUI's visual behavior typically requires human testers to interact with the GUI and to observe whether the expected results of interaction are presented. This paper presents a new approach to GUI testing using ...

  11. Photovoltaic Module Qualification Plus Testing

    SciTech Connect (OSTI)

    Kurtz, S.; Wohlgemuth, J.; Kempe, M.; Bosco, N.; Hacke, P.; Jordan, D.; Miller, D. C.; Silverman, T. J.; Phillips, N.; Earnest, T.; Romero, R.

    2013-12-01

    This report summarizes a set of test methods that are in the midst of being incorporated into IEC 61215 for certification of a module design or other tests that go beyond certification to establish bankability.

  12. Generic air sampler probe tests

    SciTech Connect (OSTI)

    Glissmeyer, J.A.; Ligotke, M.W.

    1995-11-01

    Tests were conducted to determine the best nozzle and probe designs for new air sampling systems to be installed in the ventilation systems of some of the waste tanks at the Hanford Site in Richland, Washington. Isokinetic nozzle probes and shrouded probes were tested. The test aerosol was sodium-fluorescein-tagged oleic acid. The test parameters involved particle sizes from 1 to 15 {mu}m, air velocities from 3 to 15 m/s. The results of the tests show that shrouded probes can deliver samples with significantly less particle-size bias then the isokinetic nozzle probes tested. Tests were also conducted on two sample flow splitters to determine particle loss as a function of aerodynamic particle size. The particle size range covered in these tests was 5 to 15 {mu}m. The results showed little particle loss, but did show a bias in particle concentration between the two outlets of each splitter for the larger particle sizes.

  13. TEST PROCEDURE VALIDATION TEST OF A DISCRIMINATING TRITIUM MONITOR...

    Office of Environmental Management (EM)

    from the low concentration of other materials being measured. WE NOTE THAT Most ionizing radiation detector types exhibit significant cross talk when presented with multiple...

  14. Types of Lighting | Department of Energy

    Energy Savers [EERE]

    For a technical comparison of the different types of lighting, visit Energy Basics. External Resources Find a Lighting Designer - International Association of Lighting...

  15. Nested Refinement Types for JavaScript /

    E-Print Network [OSTI]

    Chugh, Ravi

    2013-01-01

    Pierce. Types and Programming Languages. MIT Press, 2002. [In Principles of Programming Languages (POPL), 1999. [105]In Functional Programming Languages and Architecture (FPCA),

  16. Nutritional systems biology of type 2 diabetes

    E-Print Network [OSTI]

    Zhao, Y; Barrere-Cain, RE; Yang, X

    2015-01-01

    HF (2015) Circadian systems biology in Metazoa. BriefingsNutritional systems biology: defini- tions and approaches.PAPER Nutritional systems biology of type 2 diabetes Yuqi

  17. Types of Lighting | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    selection. Types of lighting include: Fluorescent Incandescent Outdoor solar Light-emitting diode (LED) Also learn how energy-efficient lightbulbs compare to traditional...

  18. Psoriasis and psoriatic arthritis, axial type

    E-Print Network [OSTI]

    White, Katherine L.

    2001-01-01

    Psoriasis and psoriatic arthritis, axial type Katherine L.has a 20-year history of psoriasis, progressive psoriaticof psoriatic arthritis and psoriasis: a randomized trial.

  19. Turbulent Combustion in Type Ia Supernova Models

    E-Print Network [OSTI]

    F. K. Roepke; W. Hillebrandt

    2006-09-15

    We review the astrophysical modeling of type Ia supernova explosions and describe numerical methods to implement numerical simulations of these events. Some results of such simulations are discussed.

  20. Systematic Testing Henrik Brbak Christensen

    E-Print Network [OSTI]

    Christensen, Henrik Bærbak

    not enough. We need to define some commonly accepted measurable quantity that we can use as yardstick. To test the System.abs(int a) you could define a test case like Input: -37 Expected Output: +37 The notionSystematic Testing Henrik Bærbak Christensen Department of Computer Science University of Aarhus

  1. December 2000 A STATISTICAL TEST

    E-Print Network [OSTI]

    December 2000 A STATISTICAL TEST SUITE FOR RANDOM AND PSEUDORANDOM NUMBER GENERATORS challenges in authentication protocols. NIST Special Publication (SP) 800-22, A Statistical Test Suite testing of random number and pseudorandom number generators (RNGs and PRNGs) that may be used for many

  2. ONTOLOGY OF TEST Larisa Soldatova

    E-Print Network [OSTI]

    Mizoguchi, Riichiro

    In the present paper design of test generation systems (TGS) based on test ontology and student's knowledge model is discussed. Main functions and regimes of TGS are described. Student's knowledge base is divided into two SYSTEM Users of information system for test generation TGS are: a professor or an instructor, who would

  3. TRT meeting Feb 03 Pauline Gagnon Indiana University 1 Acceptance tests for barrel modules

    E-Print Network [OSTI]

    Gagnon, Pauline

    tension 90% 80% 100% stringing 80% 100% not tested HV checks 100% 20% not done HV conditioning in design 20% not done gain mapping designed 100% not done #12;TRT meeting ­ Feb 03 Pauline Gagnon ­ Indiana Circulate ventilation through 3 modules: type 1,2 3 Active gas in series through 2 modules of the same type

  4. WASTE DESCRIPTION TYPE OF PROJECT POUNDS REDUCED,

    E-Print Network [OSTI]

    for reduction in mixed waste generation Pump Oil Substitution 51 Hazardous Waste / Industrial Waste $3,520 $6 with the subsequent clean up costs ($15,000). Hydraulic Oil Product Substitution 3,000 Industrial Waste $26,000 $0 $26WASTE DESCRIPTION TYPE OF PROJECT POUNDS REDUCED, REUSED, RECYCLED OR CONSERVED IN 2003 WASTE TYPE

  5. WASTE DESCRIPTION TYPE OF PROJECT POUNDS REDUCED,

    E-Print Network [OSTI]

    reflect avoided waste disposal costs and lower material purchase costs ($6000) Hydraulic Oil ProductWASTE DESCRIPTION TYPE OF PROJECT POUNDS REDUCED, REUSED, RECYCLED OR CONSERVED IN 2002 WASTE TYPE DESCRIPTION DETAILS * Electrophoretic Mini-Gels Microscale Chemical Use 2,200 Hazardous Waste - Lab Pack $10

  6. WASTE DESCRIPTION TYPE OF PROJECT POUNDS REDUCED,

    E-Print Network [OSTI]

    . Removed grit and sludge are mixed with the waste oil. Photon-counting spectrofluorimeter Substitution 54 or composted at the stump dump. Plant Engineering grounds vehicle wash system * Waste minimization 8,000 OilsWASTE DESCRIPTION TYPE OF PROJECT POUNDS REDUCED, REUSED, RECYCLED OR CONSERVED IN 2007 WASTE TYPE

  7. Serum markers for type II diabetes mellitus

    DOE Patents [OSTI]

    Metz, Thomas O; Qian, Wei-Jun; Jacobs, Jon M; Polpitiya, Ashoka D; Camp, II, David G; Smith, Richard D

    2014-03-18

    A method for identifying persons with increased risk of developing type 2 diabetes mellitus utilizing selected biomarkers described hereafter either alone or in combination. The present invention allows for broad based, reliable, screening of large population bases and provides other advantages, including the formulation of effective strategies for characterizing, archiving, and contrasting data from multiple sample types under varying conditions.

  8. Archived Reference Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  9. Archived Reference Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  10. Archived Reference Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  11. Archived Reference Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  12. Typing Progress in Communication-Centred Systems

    E-Print Network [OSTI]

    Vasconcelos, Vasco Thudichum

    Typing Progress in Communication-Centred Systems Hugo Torres Vieira and Vasco Thudichum Vasconcelos for the analysis of progress in session-based communication centred systems. Our development is car- ried out LaSIGE, Faculdade de Ci^encias, Universidade de Lisboa, Portugal Abstract. We present a type system

  13. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  14. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  15. Archived Reference Building Type: Outpatient health care

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  16. Archived Reference Building Type: Outpatient health care

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  17. Spatial Data Types: Conceptual Foundation for

    E-Print Network [OSTI]

    Güting, Ralf Hartmut

    are necessary to model geometry and to suitably represent geometric data in data- base systems. These data types. Their definition is to a large degree responsible for a successful design of spatial data models-oriented, or some other kind of data model. Hence, the definition and implementation of spatial data types

  18. Some Properties of Type I' String Theory

    E-Print Network [OSTI]

    John H. Schwarz

    1999-07-26

    The T-dual formulation of Type I superstring theory, sometimes called Type I' theory, has a number of interesting features. Here we review some of them including the role of D0-branes and D8-branes in controlling possible gauge symmetry enhancement.

  19. 2006 Lexus RX400h-4807 Hybrid Electric Vehicle Battery Test Results

    SciTech Connect (OSTI)

    Tyler Gray; Chester Motloch; James Francfort

    2010-01-01

    The U.S. Department of Energy's Advanced Vehicle Testing Activity conducts several different types of tests on hybrid electric vehicles, including testing hybrid electric vehicles batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of accelerated testing. This report documents the battery testing performed and battery testing results for the 2007 Lexus RX900h hybrid electric vehicle (Vin Number JTJHW31U660004807). Testing was performed by the Electric Transportation Engineering Corporation. The Advanced Vehicle Testing Activity is part of the U.S. Department of Energy's Vehicle Technologies Program. The Idaho National Laboratory and the Electric Transportation Engineering Corporation conduct Advanced Vehicle Testing Activity for the U.S. Department of Energy.

  20. 2006 Lexus RX400h-2575 Hybrid Electric Vehicle Battery Test Results

    SciTech Connect (OSTI)

    Tyler Gray; Chester Motloch; James Francfort

    2010-01-01

    The U.S. Department of Energy's Advanced Vehicle Testing Activity conducts several different types of tests on hybrid electric vehicles, including testing hybrid electric vehicles batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of accelerated testing. This report documents the battery testing performed and battery testing results for the 2007 Lexus RX900h hybrid electric vehicle (Vin Number JTJHW31U660002575). Testing was performed by the Electric Transportation Engineering Corporation. The Advanced Vehicle Testing Activity is part of the U.S. Department of Energy's Vehicle Technologies Program. The Idaho National Laboratory and the Electric Transportation Engineering Corporation conduct Advanced Vehicle Testing Activity for the U.S. Department of Energy.

  1. Water Loss Test Results for Lateral A Before and After Lining Hidalgo County Irrigation District No. 2 

    E-Print Network [OSTI]

    Leigh, E.; Fipps, G.

    2008-01-01

    for Test SJ14 ? Lateral A-8 (West of Stewart Rd.) District Test ID Hidalgo County Irrigation District No.2 SJ14 Canal Lining Type Lateral A-8 Concrete/GeoLiner Top Width Start Date/Time Finish Date/Time 15.977 feet (avg.) July 26, 2005 Test Length... stream_source_info TR-328 Water Loss Test Results Lateral A - Hidalgo Co. ID No. 2.pdf.txt stream_content_type text/plain stream_size 24542 Content-Encoding ISO-8859-1 stream_name TR-328 Water Loss Test Results Lateral A - Hidalgo Co...

  2. Verifica Formale Generazione Automatica di Test

    E-Print Network [OSTI]

    Robbiano, Lorenzo

    Verifica Formale Testing Generazione Automatica di Test Analisi Sperimentale Conclusioni Generazione Automatica di Test per Analisi di Copertura di Software Safety Critical utilizzando Bounded Model maggio 2011 M.Narizzano #12;Verifica Formale Testing Generazione Automatica di Test Analisi Sperimentale

  3. Types of Utility Energy Service Contracts | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Project Financing Utility Energy Service Contracts Types of Utility Energy Service Contracts Types of Utility Energy Service Contracts Several types of contracts are used as...

  4. Interagency Field Test & Evaluation: Field Test 2 Public Fact Sheet

    SciTech Connect (OSTI)

    Brian Connor

    2013-03-30

    This fact sheet summarizes the second field tests of technologies intended to address wind turbine interference with land-based surveillance radar, which took place in Lubbock, TX.

  5. Membrane-Associated Methane Monooygenase from Type X and Type I Methanotrophs

    SciTech Connect (OSTI)

    Antholine, William E.; DiSpirito, Alan A.

    2009-11-30

    Membrane-Associated Methane Monooxygenases from Type X and Type I Methanotrophs A.A. DiSirito and W.E. Antholine Project Number: DE-FG02-00ER15446 Final project report.

  6. Improving Type Ia Supernova Standard Candle Cosmology Measurements Using Observations of Early-Type Host Galaxies

    E-Print Network [OSTI]

    Meyers, Joshua Evan

    2012-01-01

    Host Galaxies of Type Ia Supernovae Introduction SN Ia Hosts109 C HAPTER 1 Cosmology, Type Ia Supernovae and HostGalaxies Observations of supernovae have played a role in

  7. Fully Reflexive Intensional Type Analysis in Type Erasure Semantics # Bratin Saha Valery Trifonov Zhong Shao

    E-Print Network [OSTI]

    Trifonov, Valery

    Fully Reflexive Intensional Type Analysis in Type Erasure Semantics # Bratin Saha Valery Trifonov Zhong Shao Department of Computer Science Yale University {saha,trifonov,shao}@cs.yale.edu Abstract

  8. Benchmark specifications for EBR-II shutdown heat removal tests

    SciTech Connect (OSTI)

    Sofu, T.; Briggs, L. L.

    2012-07-01

    Argonne National Laboratory (ANL) is hosting an IAEA-coordinated research project on benchmark analyses of sodium-cooled fast reactor passive safety tests performed at the Experimental Breeder Reactor-II (EBR-II). The benchmark project involves analysis of a protected and an unprotected loss of flow tests conducted during an extensive testing program within the framework of the U.S. Integral Fast Reactor program to demonstrate the inherently safety features of EBR-II as a pool-type, sodium-cooled fast reactor prototype. The project is intended to improve the participants' design and safety analysis capabilities for sodium-cooled fast reactors through validation and qualification of safety analysis codes and methods. This paper provides a description of the EBR-II tests included in the program, and outlines the benchmark specifications being prepared to support the IAEA-coordinated research project. (authors)

  9. Model- and calibration-independent test of cosmic acceleration

    E-Print Network [OSTI]

    Marina Seikel; Dominik J. Schwarz

    2009-01-27

    We present a calibration-independent test of the accelerated expansion of the universe using supernova type Ia data. The test is also model-independent in the sense that no assumptions about the content of the universe or about the parameterization of the deceleration parameter are made and that it does not assume any dynamical equations of motion. Yet, the test assumes the universe and the distribution of supernovae to be statistically homogeneous and isotropic. A significant reduction of systematic effects, as compared to our previous, calibration-dependent test, is achieved. Accelerated expansion is detected at significant level (4.3 sigma in the 2007 Gold sample, 7.2 sigma in the 2008 Union sample) if the universe is spatially flat. This result depends, however, crucially on supernovae with a redshift smaller than 0.1, for which the assumption of statistical isotropy and homogeneity is less well established.

  10. Using JULE to Generate a Compliance Test Suite for the UML Standard Panuchart Bunyakiati, Anthony Finkelstein, James Skene and Clovis Chapman

    E-Print Network [OSTI]

    Finkelstein, Anthony

    Using JULE to Generate a Compliance Test Suite for the UML Standard Panuchart Bunyakiati, Anthony certification - test suite generation. The framework uses UML models as the test inputs for the bounded exhaustive-testing approach. Within a size bound for the metamodel types, JULE enumerates only the set of non

  11. Experimental Test of Bell inequalities with Six-Qubit Graph States

    E-Print Network [OSTI]

    Wei-Bo Gao; Xing-Can Yao; Ping Xu; Otfried Gühne; Adán Cabello; Chao-Yang Lu; Tao Yang; Zeng-Bing Chen; Jian-Wei Pan

    2011-01-04

    We report on the experimental realization of two different Bell inequality tests based on six-qubit linear-type and Y-shape graph states. For each of these states, the Bell inequalities tested are optimal in the sense that they provide the maximum violation among all Bell inequalities with stabilizing observables and possess the maximum resistance to noise.

  12. Proceedings of the Sudden Oak Death Third Science Symposium In Vitro Testing of Biological Control

    E-Print Network [OSTI]

    to the biocontrol agents tested. Key words: Phytophthora ramorum, Trichoderma spp., Streptomyces, biological control in response to biocontrol agents among isolates of P. ramorum belonging to different mating types and from for screening of biocontrol agents (BCAs) (table 1). To test the efficacy of biocontrol products in controlling

  13. Identification of Local Clusters for Count Data: A Model-Based Moran's I Test

    E-Print Network [OSTI]

    Zhang, Tonglin

    in detecting local clusters by local association terms with an acceptable type I error probability. When usedIdentification of Local Clusters for Count Data: A Model-Based Moran's I Test Tonglin Zhang and Ge@wvu.edu 0 #12;Identification of Local Clusters for Count Data: A Model-Based Moran's I Test Abstract We set

  14. SEE Tests of the TileCal Optical Interface Board K. Anderson, J. Pilcher

    E-Print Network [OSTI]

    radiation levels of 21 July 2000, the required safety factors, and resulting radiation tolerance criteria. Radiation levels in the extended barrels are similar or smaller. Radiation Type Simulated Level Safety seconds each, at design luminosity. 3. Test Setup The tests were performed on 15 September, 2001

  15. TESLA-FEL 2003-04 Waveguide Monitors -a New Type of Beam Position

    E-Print Network [OSTI]

    TESLA-FEL 2003-04 Waveguide Monitors - a New Type of Beam Position Monitors for the TTF FEL U. Hahn Laser (FEL) at the TESLA Test Facilty (TTF) requires the electron trajectory to be aligned bench in the laboratory and with beam. TTF FEL measurement results are also presented and possible

  16. Testing of Gas Reactor Fuel and Materials in the Advanced Test Reactor

    SciTech Connect (OSTI)

    S. Blaine Grover

    2006-10-01

    The recent growth in interest for high temperature gas reactors has resulted in an increased need for materials and fuel testing for this type of reactor. The Advanced Test Reactor (ATR), located at the US Department of Energy’s Idaho National Laboratory, has long been involved in testing gas reactor fuel and materials, and has facilities and capabilities to provide the right environment for gas reactor irradiation experiments. These capabilities include both passive sealed capsule experiments, and instrumented/actively controlled experiments. The instrumented/actively controlled experiments typically contain thermocouples and control the irradiation temperature, but on-line measurements and controls for pressure and gas environment have also been performed in past irradiations. The ATR has an existing automated gas temperature control system that can maintain temperature in an irradiation experiment within very tight bounds, and has developed an on-line fission product monitoring system that is especially well suited for testing gas reactor particle fuel. The ATR’s control system, which consists primarily of vertical cylinders used to rotate neutron poisons/reflectors toward or away from the reactor core, provides a constant vertical flux profile over the duration of each operating cycle. This constant chopped cosine shaped axial flux profile, with a relatively flat peak at the vertical centre of the core, is more desirable for experiments than a constantly moving axial flux peak resulting from a control system of axially positioned control components which are vertically withdrawn from the core.

  17. Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Task 3 Full-scale Test Results

    SciTech Connect (OSTI)

    Gary Blythe

    2007-05-01

    This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, 'Field Testing of a Wet FGD Additive'. The objective of the project is to demonstrate the use of a flue gas desulfurization (FGD) additive, Degussa Corporation's TMT-15, to prevent the reemission of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate whether the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine TMT salt that can be separated from the FGD liquor and bulk solid byproducts for separate disposal. The project is conducting pilot- and full-scale tests of the TMT-15 additive in wet FGD absorbers. The tests are intended to determine required additive dosages to prevent Hg{sup 0} reemissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Power River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, TXU Generation Company LP, Southern Company, and Degussa Corporation. TXU Generation has provided the Texas lignite/PRB cofired test site for pilot FGD tests, Monticello Steam Electric Station Unit 3. Southern Company is providing the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot- and full-scale jet bubbling reactor (JBR) FGD systems to be tested. IPL, an AES company, provided the high-sulfur Eastern bituminous coal full-scale FGD test site and cost sharing. Degussa Corporation is providing the TMT-15 additive and technical support to the test program as cost sharing. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves management and reporting. The other four tasks involve field testing on FGD systems, either at pilot or full scale. The four tasks include: Task 2 - Pilot Additive Testing in Texas Lignite Flue Gas; Task 3 - Full-scale FGD Additive Testing in High-sulfur Eastern Bituminous Flue Gas; Task 4 - Pilot Wet Scrubber Additive Tests at Plant Yates; and Task 5 - Full-scale Additive Tests at Plant Yates. The pilot-scale tests were completed in 2005 and have been previously reported. This topical report presents the results from the Task 3 full-scale additive tests, conducted at IPL's Petersburg Station Unit 2. The Task 5 full-scale additive tests will be conducted later in calendar year 2007.

  18. Evaluation of Smart Irrigation Controllers: Initial Bench Testing Results 

    E-Print Network [OSTI]

    Swanson, Charles; Fipps, Guy

    2009-01-01

    stream_source_info TR-354 Inital Results-Smart Controller Report 7-16-09.pdf.txt stream_content_type text/plain stream_size 20709 Content-Encoding ISO-8859-1 stream_name TR-354 Inital Results-Smart Controller Report 7-16-09.pdf....txt Content-Type text/plain; charset=ISO-8859-1 COLLEGE OF AGRICULTURE AND LIFE SCIENCES TR-354 2009 Evaluation of Smart Irrigation Controllers: Initial Bench Testing Results July 2009 By Charles Swanson...

  19. The decay of debris disks around solar-type stars

    SciTech Connect (OSTI)

    Sierchio, J. M.; Rieke, G. H.; Su, K. Y. L.; Gáspár, Andras, E-mail: sierchio@mit.edu [Steward Observatory, University of Arizona, Tucson, AZ 85721 (United States)

    2014-04-10

    We present a Spitzer MIPS study of the decay of debris disk excesses at 24 and 70 ?m for 255 stars of types F4-K2. We have used multiple tests, including consistency between chromospheric and X-ray activity and placement on the H-R diagram, to assign accurate stellar ages. Within this spectral type range, at 24 ?m, 13.6% ± 2.8% of the stars younger than 1 Gyr have excesses at the 3? level or more, whereas none of the older stars do, confirming previous work. At 70 ?m, 22.5% ± 3.6% of the younger stars have excesses at ?3? significance, whereas only 4.7{sub ?2.2}{sup +3.7}% of the older stars do. To characterize the far-infrared behavior of debris disks more robustly, we doubled the sample by including stars from the DEBRIS and DUNES surveys. For the F4-K4 stars in this combined sample, there is only a weak (statistically not significant) trend in the incidence of far-infrared excess with spectral type (detected fractions of 21.9{sub ?4.3}{sup +4.8}%, late F; 16.5{sub ?3.3}{sup +3.9}%, G; and 16.9{sub ?5.0}{sup +6.3}%, early K). Taking this spectral type range together, there is a significant decline between 3 and 4.5 Gyr in the incidence of excesses, with fractional luminosities just under 10{sup –5}. There is an indication that the timescale for decay of infrared excesses varies roughly inversely with the fractional luminosity. This behavior is consistent with theoretical expectations for passive evolution. However, more excesses are detected around the oldest stars than are expected from passive evolution, suggesting that there is late-phase dynamical activity around these stars.

  20. Correlation of Simulation Examination to Written Test Scores for Advanced Cardiac Life Support Testing: Prospective Cohort Study

    E-Print Network [OSTI]

    2015-01-01

    simulation evaluation. Mean+SD Multiple choice test Cardiacrhythm test Clinicalmanagement test Mean of three written tests Simulation test

  1. MA303: Practice Test 1

    E-Print Network [OSTI]

    2015-09-29

    MA303: Practice Test 1. Answer all questions, showing your working. Write your name on the question paper and hand it in together with your solutions.

  2. Test Driving the Toyota Mirai

    Broader source: Energy.gov [DOE]

    Watch a video of Energy Secretary Ernest Moniz test driving the Toyota Mirai, the first fuel cell electric vehicle available for sale.

  3. MA303: Practice Test 2

    E-Print Network [OSTI]

    2015-11-06

    MA303: Practice Test 2. Answer all questions, showing your working. Write your name on the question paper and hand it in together with your solutions.

  4. Optimizing Benefits of Testing Efforts

    SciTech Connect (OSTI)

    Kurtz, Sarah

    2015-09-14

    This presentation explores the need to prioritize testing efforts in order to achieve the highest confidence in PV reliability at the lowest cost.

  5. National Spill Test Technology Database

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Sheesley, David [Western Research Institute

    Western Research Institute established, and ACRC continues to maintain, the National Spill Technology database to provide support to the Liquified Gaseous Fuels Spill Test Facility (now called the National HAZMAT Spill Center) as directed by Congress in Section 118(n) of the Superfund Amendments and Reauthorization Act of 1986 (SARA). The Albany County Research Corporation (ACRC) was established to make publicly funded data developed from research projects available to benefit public safety. The founders since 1987 have been investigating the behavior of toxic chemicals that are deliberately or accidentally spilled, educating emergency response organizations, and maintaining funding to conduct the research at the DOEÆs HAZMAT Spill Center (HSC) located on the Nevada Test Site. ACRC also supports DOE in collaborative research and development efforts mandated by Congress in the Clean Air Act Amendments. The data files are results of spill tests conducted at various times by the Silicones Environmental Health and Safety Council (SEHSC) and DOE, ANSUL, Dow Chemical, the Center for Chemical Process Safety (CCPS) and DOE, Lawrence Livermore National Laboratory (LLNL), OSHA, and DOT; DuPont, and the Western Research Institute (WRI), Desert Research Institute (DRI), and EPA. Each test data page contains one executable file for each test in the test series as well as a file named DOC.EXE that contains information documenting the test series. These executable files are actually self-extracting zip files that, when executed, create one or more comma separated value (CSV) text files containing the actual test data or other test information.

  6. Beam test of the SDC barrel EM calorimeter test module

    SciTech Connect (OSTI)

    Balka, L.; Guarino, V.; Hill, N.

    1994-05-01

    The SDC barrel electromagnetic calorimeter test module was exposed to beams of high energy pions and electrons in the MP9 test beam at Fermilab in the fall of 1991. Data were collected on resolution, light yield, signal timing and hermiticity. These data demonstrated that the design met the specifications for the barrel electromagnetic calorimeter of the Solenoidal Detector collaboration (SDC).

  7. Polymer Testing 26 (2007) 614618 Short Communication: Test Method

    E-Print Network [OSTI]

    Natelson, Douglas

    2007-01-01

    rights reserved. Keywords: Non-destructive testing; Terahertz spectroscopy; Polymeric compounds; Additive range between 100 GHz and a few THz is a promising technique for non- destructive testing of polymeric to be a promising non-destructive technique for quality control in compounding processes. r 2007 Elsevier Ltd. All

  8. Life cycle test of the NOXSO process

    SciTech Connect (OSTI)

    Ma, W.T.; Haslbeck, J.L.; Neal, L.G.

    1990-05-01

    This paper summarizes the data generated by the NOXSO Life Cycle Test Unit (LCTU). The NOXSO process is a dry flue gas treatment system that employs a reusable sorbent. The sorbent consists of sodium carbonate impregnated on a high-surface-area gamma alumina. A fluidized bed of sorbent simultaneously removes SO{sub 2} and NO{sub x} from flue gas at a temperature of 250{degrees}F. The spent sorbent is regenerated for reuse by treatment at high temperature with a reducing gas. This regeneration reduces sorbed sulfur compounds to SO{sub 2}, H{sub 2}S, and elemental sulfur. The SO{sub 2} and H{sub 2}S are then converted to elemental sulfur in a Claus-type reactor. The sulfur produced is a marketable by-product of the process. Absorbed nitrogen oxides are decomposed and evolved on heating the sorbent to regeneration temperature.

  9. Test Protocol Document, Hydrogen Safety Sensor Testing; Phase I: Non-Flammable Mixtures

    SciTech Connect (OSTI)

    Burgess, R.; Blake, C.; Tracy, C. E.

    2008-09-01

    This test protocol document includes an overview of hydrogen sensor technologies, test hardware requrements, and an outline of potential testing.

  10. CHARACTERIZATION OF SIALON-TYPE MATERIALS

    E-Print Network [OSTI]

    Spencer, P.N.

    2010-01-01

    an Economical Refractory Material", Industrial Heating, 50-of Sialon-Type Materials Newman Spencer Lawrence BerkeleyEXPERIHENTAL PROCEDURES A. The Material L Ml H2 M3 and M4 B.

  11. On abstract data types presented by multiequations

    E-Print Network [OSTI]

    Rosický, Jirí

    11511, Egypt J. Rosick'y 1 Masaryk University, Jan'aŸckovo n'am. 2a, 662 95 Brno, Czech Republic first illustrate the expressive power of multiequations on concrete examples of algebras and data types

  12. Type Systems For Polynomial-time Computation 

    E-Print Network [OSTI]

    Hofmann, Martin

    This thesis introduces and studies a typed lambda calculus with higher-order primitive recursion over inductive datatypes which has the property that all definable number-theoretic functions are polynomial time computable. ...

  13. Data mining for structure type prediction

    E-Print Network [OSTI]

    Tibbetts, Kevin (Kevin Joseph)

    2004-01-01

    Determining the stable structure types of an alloy is critical to determining many properties of that material. This can be done through experiment or computation. Both methods can be expensive and time consuming. Computational ...

  14. Defining photometric peculiar type Ia supernovae

    SciTech Connect (OSTI)

    González-Gaitán, S.; Pignata, G.; Förster, F.; Gutiérrez, C. P.; Bufano, F.; Galbany, L.; Hamuy, M.; De Jaeger, T. [Millennium Institute of Astrophysics, Casilla 36-D, Santiago (Chile); Hsiao, E. Y.; Phillips, M. M. [Carnegie Observatories, Las Campanas Observatory, Casilla 601, La Serena (Chile); Folatelli, G. [Kavli Institute for the Physics and Mathematics of the Universe, the University of Tokyo, Kashiwa 277-8583 (Kavli IPMU, WPI) (Japan); Anderson, J. P., E-mail: sgonzale@das.uchile.cl [European Southern Observatory, Alonso de Córdova 3107, Casilla 19, Santiago (Chile)

    2014-11-10

    We present a new photometric identification technique for SN 1991bg-like type Ia supernovae (SNe Ia), i.e., objects with light curve characteristics such as later primary maxima and the absence of a secondary peak in redder filters. This method is capable of selecting this sub-group from the normal type Ia population. Furthermore, we find that recently identified peculiar sub-types such as SNe Iax and super-Chandrasekhar SNe Ia have photometric characteristics similar to 91bg-like SNe Ia, namely, the absence of secondary maxima and shoulders at longer wavelengths, and can also be classified with our technique. The similarity of these different SN Ia sub-groups perhaps suggests common physical conditions. This typing methodology permits the photometric identification of peculiar SNe Ia in large upcoming wide-field surveys either to study them further or to obtain a pure sample of normal SNe Ia for cosmological studies.

  15. University of Oregon Libraries Types of Periodicals

    E-Print Network [OSTI]

    Lockery, Shawn

    University of Oregon Libraries Types of Periodicals Scholarly Sources Popular Sources SCHOLARLY American Quarterly RN Automotive News Library Journal Restaurants & Institutions Chemical Engineering News & biographical information Statistics, including forecasts Some book reviews Commentary on political & social

  16. Operations and Maintenance for Major Equipment Types

    Broader source: Energy.gov [DOE]

    Equipment lies at the heart of all operations and maintenance (O&M) activities. This equipment varies greatly across the Federal sector in age, size, type, model, condition, etc.

  17. Faculty Salary Administration Policy Type: Administrative

    E-Print Network [OSTI]

    Hammack, Richard

    Faculty Salary Administration Policy Type: Administrative Responsible Office: Office of the Provost (VCU) and the guidelines to be followed in setting or modifying faculty salaries. Noncompliance) .............................................................................. 8 #12;Faculty Salary Administration - 2 - Approved: 08/12/2014 · PRES

  18. Automatic Utterance Type Detection Using Suprasegmental Features 

    E-Print Network [OSTI]

    Wright, Helen

    The goal of the work presented here is to automatically predict the type of an utterance in spoken dialogue by using automatically extracted suprasegmental information. For this task we present and compare three stochastic algorithms: hidden Markov...

  19. Renewable Energy Opportunities by Renovation Type

    Broader source: Energy.gov [DOE]

    Renewable energy opportunities should be considered and identified in the earliest stages of Federal project planning and the team should assess the renewable energy options based on the type of...

  20. Termination Checking with Types Strong Normalization for

    E-Print Network [OSTI]

    Abel, Andreas

    Termination Checking with Types Strong Normalization a program can be separated into two parts: As the first step, partial correctness is established by verifying that a program matches its specification; then, termination is shown to obtain full correctness

  1. Genomic analysis of control of cell type

    E-Print Network [OSTI]

    Frampton, Garrett M

    2011-01-01

    In mammalian development, a single fertilized egg grows into a complex organism, comprised of organs and tissues made up of hundreds of different specialized cell types. All of these cells contain the same genome, but ...

  2. Test probe for surface mounted leadless chip carrier

    DOE Patents [OSTI]

    Meyer, K.L.; Topolewski, J.

    1987-10-02

    A test probe for a surface mounted leadless chip carrier is disclosed. The probe includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe. 1 fig.

  3. Trace element geochemistry of ordinary chondrite chondrules: the type I/type II chondrule dichotomy

    E-Print Network [OSTI]

    Jacquet, Emmanuel; Gounelle, Matthieu

    2015-01-01

    We report trace element concentrations of silicate phases in chondrules from LL3 ordinary chondrites Bishunpur and Semarkona. Results are similar to previously reported data for carbonaceous chondrites, with rare earth element (REE) concentrations increasing in the sequence olivine ~ 10 K/h) than type I chondrules. Appreciable Na concentrations (3-221 ppm) are measured in olivine from both chondrule types; type II chondrules seem to have behaved as closed systems, which may require chondrule formation in the vicinity of protoplanets or planetesimals. At any rate, higher solid concentrations in type II chondrule forming regions may explain the higher oxygen fugacities they record compared to type I chondrules. Type I and type II chondrules formed in different environments and the correlation between high solid concentrations and/or oxygen fugacities with rapid cooling rates is a key constraint that chondrule formation models must account for.

  4. Transportation Safeguards & Security Test Bed (TSSTB) | ORNL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Transportation Safeguards and Security Test Bed May 30, 2013 The Transportation Safeguards and Security Test Bed consists of a test-bed vehicle and a monitoringlaboratorytraining...

  5. DYNA3D/ParaDyn Regression Test Suite Inventory

    SciTech Connect (OSTI)

    Lin, J I

    2011-01-25

    The following table constitutes an initial assessment of feature coverage across the regression test suite used for DYNA3D and ParaDyn. It documents the regression test suite at the time of production release 10.1 in September 2010. The columns of the table represent groupings of functionalities, e.g., material models. Each problem in the test suite is represented by a row in the table. All features exercised by the problem are denoted by a check mark in the corresponding column. The definition of ''feature'' has not been subdivided to its smallest unit of user input, e.g., algorithmic parameters specific to a particular type of contact surface. This represents a judgment to provide code developers and users a reasonable impression of feature coverage without expanding the width of the table by several multiples. All regression testing is run in parallel, typically with eight processors. Many are strictly regression tests acting as a check that the codes continue to produce adequately repeatable results as development unfolds, compilers change and platforms are replaced. A subset of the tests represents true verification problems that have been checked against analytical or other benchmark solutions. Users are welcomed to submit documented problems for inclusion in the test suite, especially if they are heavily exercising, and dependent upon, features that are currently underrepresented.

  6. Standard practice for modified salt spray (fog) testing

    E-Print Network [OSTI]

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers and sets forth conditions for five modifications in salt spray (fog) testing for specification purposes. These are in chronological order of their development: 1.1.1 Annex A1, acetic acid-salt spray test, continuous. 1.1.2 Annex A2, cyclic acidified salt spray test. 1.1.3 Annex A3, seawater acidified test, cyclic (SWAAT). 1.1.4 Annex A4, SO2 salt spray test, cyclic. 1.1.5 Annex A5, dilute electrolyte cyclic fog dry test. 1.2 This practice does not prescribe the type of modification, test specimen or exposure periods to be used for a specific product, nor the interpretation to be given to the results. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to consult and establish appropriate safety and health practices and determine the applicabilit...

  7. Ground test facility for SEI nuclear rocket engines

    SciTech Connect (OSTI)

    Harmon, C.D.; Ottinger, C.A.; Sanchez, L.C.; Shipers, L.R.

    1992-08-01

    Nuclear Thermal Propulsion (NTP) has been identified as a critical technology in support of the NASA Space Exploration Initiative (SEI). In order to safely develop a reliable, reusable, long-lived flight engine, facilities are required that will support ground tests to qualify the nuclear rocket engine design. Initial nuclear fuel element testing will need to be performed in a facility that supports a realistic thermal and neutronic environment in which the fuel elements will operate at a fraction of the power of a flight weight reactor/engine. Ground testing of nuclear rocket engines is not new. New restrictions mandated by the National Environmental Protection Act of 1970, however, now require major changes to be made in the manner in which reactor engines are now tested. These new restrictions now preclude the types of nuclear rocket engine tests that were performed in the past from being done today. A major attribute of a safely operating ground test facility is its ability to prevent fission products from being released in appreciable amounts to the environment. Details of the intricacies and complications involved with the design of a fuel element ground test facility are presented in this report with a strong emphasis on safety and economy.

  8. Testing Formula Satisfaction Eldar Fischer

    E-Print Network [OSTI]

    Fischer, Eldar

    of testing for properties defined by read once formulae, as instances of massively parametrized propertiesTesting Formula Satisfaction Eldar Fischer Oded Lachish Abstract We study the query complexity, and prove several testability and non-testability results. First we prove that any property accepted

  9. Post Combustion Test Bed Development

    SciTech Connect (OSTI)

    Cabe, James E.; King, Dale A.; Freeman, Charles J.

    2011-12-30

    Pacific Northwest National Laboratory (PNNL) assessment methodology and slip-stream testing platform enables the comprehensive early-stage evaluation of carbon capture solvents and sorbents utilizing a breadth of laboratory experimental capability as well as a testing platform at a nearby 600 MW pulverized coal-fired power plant.

  10. Tests Conducted with Strippable Coatings

    SciTech Connect (OSTI)

    K. E. Archibald; R. L. Demmer

    1999-08-01

    This report details the testing and evaluation of several strippable coatings and their use in decontamination. Pentek 604, Bartlett (TLC), and ALARA 1146 were products examined for their overall effectiveness and ease of use. Conclusions were reached about the effective use of these coatings, and field test examples, with radioactive contamination are incorporated.

  11. Test of Purity by LOCC

    E-Print Network [OSTI]

    Keiji Matsumoto

    2010-09-16

    Given n-copies of unknown bipartite (possiblly mixed) state, our task is to test whether the state is a pure state of not. Allowed to use the global operations, optimal one-sided error test is the projection onto the symmetric subspace, obviously. Is it possible to approximate the globally optimal measurement by LOCC when n is large?

  12. NISTIR 7771 Conformance Test Architecture

    E-Print Network [OSTI]

    by providing technical leadership for the Nation's measurement and standards infrastructure. ITL develops tests of technical, physical, administrative, and management standards and guidelines for the cost-effective security in the standards. Conformance testing captures the technical description of a specification and measures whether

  13. Soil Testing for Environmental Contaminates

    E-Print Network [OSTI]

    Soil Testing for Environmental Contaminates Interpreting Your Heavy Metals Test Results Olivia quantities. Soils have often been the landing spot for heavy metals, chemicals, and wastes as byproducts of industrial and agricultural pollutants. Many of these metals are present in soils natu- rally, usually

  14. SINGLE HEATER TEST FINAL REPORT

    SciTech Connect (OSTI)

    J.B. Cho

    1999-05-01

    The Single Heater Test is the first of the in-situ thermal tests conducted by the U.S. Department of Energy as part of its program of characterizing Yucca Mountain in Nevada as the potential site for a proposed deep geologic repository for the disposal of spent nuclear fuel and high-level nuclear waste. The Site Characterization Plan (DOE 1988) contained an extensive plan of in-situ thermal tests aimed at understanding specific aspects of the response of the local rock-mass around the potential repository to the heat from the radioactive decay of the emplaced waste. With the refocusing of the Site Characterization Plan by the ''Civilian Radioactive Waste Management Program Plan'' (DOE 1994), a consolidated thermal testing program emerged by 1995 as documented in the reports ''In-Situ Thermal Testing Program Strategy'' (DOE 1995) and ''Updated In-Situ Thermal Testing Program Strategy'' (CRWMS M&O 1997a). The concept of the Single Heater Test took shape in the summer of 1995 and detailed planning and design of the test started with the beginning fiscal year 1996. The overall objective of the Single Heater Test was to gain an understanding of the coupled thermal, mechanical, hydrological, and chemical processes that are anticipated to occur in the local rock-mass in the potential repository as a result of heat from radioactive decay of the emplaced waste. This included making a priori predictions of the test results using existing models and subsequently refining or modifying the models, on the basis of comparative and interpretive analyses of the measurements and predictions. A second, no less important, objective was to try out, in a full-scale field setting, the various instruments and equipment to be employed in the future on a much larger, more complex, thermal test of longer duration, such as the Drift Scale Test. This ''shake down'' or trial aspect of the Single Heater Test applied not just to the hardware, but also to the teamwork and cooperation between multiple organizations performing their part in the test.

  15. Experimental Tests of Neutron Shielding for the ATLAS Forward Region

    E-Print Network [OSTI]

    Pospísil, S; Cechák, T; Cermák, P; Jakubek, J; Kluson, J; Konícek, J; Kubasta, J; Linhart, V; Sinor, M; Leroy, C; Dolezal, Z; Leitner, R; Lukianov, G A; Soustruznik, K; Lokajícek, M; Némécek, S; Pálla, G; Sodomka, J

    1999-01-01

    Experimental tests devoted to the optimization of the neutron shielding for the ATLAS forward region were performed at the CERN-PS with a 4 GeV/c proton beam. Spectra of fast neutrons, slow neutrons and gamma rays escaping a block of iron (40$\\times$40$\\times$80 cm$^3$) shielded with different types of neutron and gamma shields (pure polyethylene - PE, borated polyethylene - BPE, lithium filled polyethylene - LiPE, lead, iron) were measured by means of plastic scintillators, a Bonner spectrometer, a HPGe detector and a slow neutron detector. Effectiveness of different types of shielding agaisnt neutrons and $\\gamma$-rays were compared. The idea of a segmented outer layer shielding (iron, BPE, iron, LiPE) for the ATLAS Forward Region was also tested.

  16. Electrochemical Corrosion Testing of Borated Stainless Steel Alloys

    SciTech Connect (OSTI)

    lister, tedd e; Mizia, Ronald E

    2007-05-01

    The Department of Energy Office of Civilian Radioactive Waste Management has specified borated stainless steel manufactured to the requirements of ASTM A 887-89, Grade A, UNS S30464, to be the material used for the fabrication of the fuel basket internals of the preliminary transportation, aging, and disposal canister system preliminary design. The long-term corrosion resistance performance of this class of borated materials must be verified when exposed to expected YMP repository conditions after a waste package breach. Electrochemical corrosion tests were performed on crevice corrosion coupons of Type 304 B4 and Type 304 B5 borated stainless steels exposed to single postulated in-package chemistry at 60°C. The results show low corrosion rates for the test period

  17. Hydrogen ICE Vehicle Testing Activities

    SciTech Connect (OSTI)

    J. Francfort; D. Karner

    2006-04-01

    The Advanced Vehicle Testing Activity teamed with Electric Transportation Applications and Arizona Public Service to develop and monitor the operations of the APS Alternative Fuel (Hydrogen) Pilot Plant. The Pilot Plant provides 100% hydrogen, and hydrogen and compressed natural gas (H/CNG)-blended fuels for the evaluation of hydrogen and H/CNG internal combustion engine (ICE) vehicles in controlled and fleet testing environments. Since June 2002, twenty hydrogen and H/CNG vehicles have accumulated 300,000 test miles and 5,700 fueling events. The AVTA is part of the Department of Energy’s FreedomCAR and Vehicle Technologies Program. These testing activities are managed by the Idaho National Laboratory. This paper discusses the Pilot Plant design and monitoring, and hydrogen ICE vehicle testing methods and results.

  18. Neutron beam testing of triblades

    SciTech Connect (OSTI)

    Michalak, Sarah E [Los Alamos National Laboratory; Du Bois, Andrew J [Los Alamos National Laboratory; Storlie, Curtis B [Los Alamos National Laboratory; Rust, William N [Los Alamos National Laboratory; Du Bois, David H [Los Alamos National Laboratory; Modl, David G [Los Alamos National Laboratory; Quinn, Heather M [Los Alamos National Laboratory; Blanchard, Sean P [Los Alamos National Laboratory; Manuzzato, Andrea [UNIV DEGLI STUDI DI PADOVA ITALY

    2010-12-16

    Four IBM Triblades were tested in the Irradiation of Chips and Electronics facility at the Los Alamos Neutron Science Center. Triblades include two dual-core Opteron processors and four PowerXCell 8i (Cell) processors. The Triblades were tested in their field configuration while running different applications, with the beam aimed at the Cell processor or the Opteron running the application. Testing focused on the Cell processors, which were tested while running five different applications and an idle condition. While neither application nor Triblade was statistically important in predicting the hazard rate, the hazard rate when the beam was aimed at the Opterons was significantly higher than when it was aimed at the Cell processors. In addition, four Cell blades (one in each Triblade) suffered voltage shorts, leading to their inoperability. The hardware tested is the same as that in the Roadrunner supercomputer.

  19. The consistency test on the cosmic evolution

    E-Print Network [OSTI]

    Gong, Yan; Zhang, Shuang-Nan; Chen, Xuelei

    2015-01-01

    We propose a new and robust method to test the consistency of the cosmic evolution given by a cosmological model. It is realized by comparing the combined quantity r_d^CMB/D_V^SN, which is derived from the comoving sound horizon r_d from cosmic microwave background (CMB) measurements and the effective distance D_V derived from low-redshift Type-Ia supernovae (SNe Ia) data, with direct and independent r_d/D_V obtained by baryon acoustic oscillation (BAO) measurements at median redshifts. We apply this test method for the LCDM and wCDM models, and investigate the consistency of the derived value of r_d/D_V from Planck 2015 and the SN Ia data sets of Union2.1 and JLA (z<1.5), and the r_d/D_V directly given by BAO data from six-degree-field galaxy survey (6dFGS), Sloan Digital Sky Survey Data Release 7 Main Galaxy Survey (SDSS-DR7 MGS), DR11 of SDSS-III, WiggleZ and Ly-alpha forecast surveys from Baryon Oscillation Spectroscopic Data (BOSS) DR-11 over 0.1

  20. Low temperature type new TMCP steel plate for LPG carriers

    SciTech Connect (OSTI)

    Suzuki, Shuichi; Bessyo, Kiyoshi; Arimochi, Kazushige; Yajima, Hiroshi; Tada, Masuo; Sakai, Daisuke

    1994-12-31

    New Thermo-Mechanical Control Process (TMCP) steel plate for LPG carriers of completely liquefied type was developed with non-nickel chemistry. The new steel plate has a capability to arrest a long running brittle crack at {minus}46 C (which is the design temperature of the liquefied LPG tanks). A high heat-input one-pass welding can be applied to this steel despite its nickel-less chemistry. These capabilities were enabled by microalloying technology with low aluminum-medium nitrogen-boron, as well as by the advanced Thermo-Mechanical Control Process. This paper describes the new concept of utilizing the trace elements and the evaluation test results as the steel plate for the LPG tank and hull, especially from the standpoints of the fracture safe reliability at high heat input welding and from that of the shop workability.

  1. Heat Pump Water Heater Durabliltiy Testing - Phase II

    SciTech Connect (OSTI)

    Baxter, VAND.

    2004-05-29

    Ten heat pump water heaters (HPWH) were placed in an environmentally controlled test facility and run through a durability test program of approximately 7300 duty cycles (actual cycles accumulated ranged from 6640 to 8324 for the ten units). Five of the units were upgraded integral types (HPWH mounted on storage tank, no pump) from the same manufacturer as those tested in our first durability program in 2001 (Baxter and Linkous, 2002). The other five were ''add-on'' type units (HPWH with circulation pump plumbed to a separate storage tank) from another manufacturer. This durability test was designed to represent approximately 7-10 years of normal operation to meet the hot water needs of a residence. The integral units operated without incident apart from two control board failures. Both of these were caused by inadvertent exposure to very hot and humid (>135 F dry bulb and >120 F dew point) conditions that occurred due to a test loop failure. It is not likely that any residential water heater would be installed where such conditions were expected so these failures are not considered a long-term reliability concern. Two of the integral HPWHs featured a condensate management system (CMS) option that effectively eliminated any need for an evaporator condensate drain, but imposed significant efficiency penalties when operating in high humidity ambient conditions. The add-on units experienced no operational failures (breakdowns with loss of hot water production) during the course of the testing. However, their control systems exhibited some performance degradation under the high temperature, high humidity test conditions--HPWHs would shut off with tank water temperatures 15-20 F lower than when operating under moderate ambient conditions. One unit developed a refrigerant leak during the test program and lost about 50% of its charge resulting in reduced efficiency. Efficiency measurements on all the integral units and four of the add-on units showed significantly higher efficiencies than conventional electric water heaters (EWH). DOE Simulated Use Tests conducted prior to starting the durability testing resulted in energy factors (EF) of about 2.3 for the integral design and 1.4 for the add-on design compared to the minimum value of 0.86 prescribed for EWHs. Based on the experience from this and the previous durability testing, there is no evidence that strongly suggests that any of the HPWHs suffered significant performance degradation after undergoing over 7000 water heat cycles.

  2. Massive Hanford Test Reactor Removed - Plutonium Recycle Test...

    Energy Savers [EERE]

    challenge on the U.S. Department of Energy's (DOE) Hanford Site by removing a 1,082-ton nuclear test reactor from the 300 Area. The River Corridor is a 220-square-mile section of...

  3. Mining Test Cases To Improve Software Maintenance

    E-Print Network [OSTI]

    Ziftci, Celal

    1.4 Software Testing and Using Tests to ImproveTom Badgett. The Art of Software Testing. Wiley Publishing,tional Conference on Software Testing, Washington DC, USA,

  4. Diplomarbeit Test der Dynamik zweier globaler

    E-Print Network [OSTI]

    Jablonowski, Christiane

    Diplomarbeit Test der Dynamik zweier globaler Wettervorhersagemodelle des Deutschen Wetterdienstes: Der Held-Suarez Test vorgelegt von Christiane Jablonowski Bonn, September 1998 Meteorologisches.1 Tests von globalen Zirkulationsmodellen . . . . . . . . . . . . . . . . . . . . . 3 1.1.1 Test von

  5. Method For Testing Properties Of Corrosive Lubricants

    DOE Patents [OSTI]

    Ohi, James (Denver, CO); De La Cruz, Jose L. (San Antonio, TX); Lacey, Paul I. (Wexford, IE)

    2006-01-03

    A method of testing corrosive lubricating media using a wear testing apparatus without a mechanical seal. The wear testing apparatus and methods are effective for testing volatile corrosive lubricating media under pressure and at high temperatures.

  6. Testing at Cryogenic Temperatures: Engineering, Materials, and Testing Support

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankADVANCEDInstallers/ContractorsPhotovoltaics »TanklessResearchEnergy TestTesting

  7. WZ Sge-Type Dwarf Novae

    E-Print Network [OSTI]

    Kato, Taichi

    2015-01-01

    We have summarized the current understanding and recently obtained findings about WZ Sge-type dwarf novae. We also reviewed the historical development of the understanding of these objects, provided the modern criteria, and reviewed the past research in relation to superhumps, early superhumps and the outburst mechanism. We regard that the presence of early superhumps (reflecting the 2:1 resonance) and long or multiple rebrightenings are the best distinguishing properties of WZ Sge-type dwarf novae. We provided the updated list of nearly 100 WZ Sge-type dwarf novae mainly based on the data obtained by the VSNET Collaboration up to Kato et al. (2015, arXiv/1507.05610) and discussed the statistics. We could detect early superhumps with amplitude larger than 0.02 mag in 63% of the studied WZ Sge-type dwarf novae, which makes early superhumps a useful distinguishing feature for WZ Sge-type dwarf novae. Theoretical light curves of early superhumps generally appear to reproduce the existence of many low-amplitude o...

  8. Test Plan: WIPP bin-scale CH TRU waste tests

    SciTech Connect (OSTI)

    Molecke, M.A.

    1990-08-01

    This WIPP Bin-Scale CH TRU Waste Test program described herein will provide relevant composition and kinetic rate data on gas generation and consumption resulting from TRU waste degradation, as impacted by synergistic interactions due to multiple degradation modes, waste form preparation, long-term repository environmental effects, engineered barrier materials, and, possibly, engineered modifications to be developed. Similar data on waste-brine leachate compositions and potentially hazardous volatile organic compounds released by the wastes will also be provided. The quantitative data output from these tests and associated technical expertise are required by the WIPP Performance Assessment (PA) program studies, and for the scientific benefit of the overall WIPP project. This Test Plan describes the necessary scientific and technical aspects, justifications, and rational for successfully initiating and conducting the WIPP Bin-Scale CH TRU Waste Test program. This Test Plan is the controlling scientific design definition and overall requirements document for this WIPP in situ test, as defined by Sandia National Laboratories (SNL), scientific advisor to the US Department of Energy, WIPP Project Office (DOE/WPO). 55 refs., 16 figs., 19 tabs.

  9. ISDSN Sensor System Phase One Test Report

    SciTech Connect (OSTI)

    Gail Heath

    2011-09-01

    This Phase 1 Test Report documents the test activities and results completed for the Idaho National Laboratory (INL) sensor systems that will be deployed in the meso-scale test bed (MSTB) at Florida International University (FIU), as outlined in the ISDSN-MSTB Test Plan. This report captures the sensor system configuration tested; test parameters, testing procedure, any noted changes from the implementation plan, acquired test data sets, and processed results.

  10. Small Wind Independent Testing (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2010-09-01

    This fact sheet describes the Small Wind Independent Testing at the NWTC and the Regional Test Centers project.

  11. Protocol Testing: Review of Methods and Relevance

    E-Print Network [OSTI]

    von Bochmann, Gregor

    Protocol Testing: Review of Methods and Relevance for Software Testing G. v. Bochmann and Alexandre Juin 1994 #12; Protocol Testing: Review of Methods and Relevance for Software Testing Gregor v the existing hardware and software testing methods would be adequate for the testing of communication protocols

  12. Protocol Testing: Review of Methods and Relevance

    E-Print Network [OSTI]

    von Bochmann, Gregor

    Protocol Testing: Review of Methods and Relevance for Software Testing G. v. Bochmann and AlexandreZal Juin 1994 #12;Protocol Testing: Review of Methods and Relevance for Software Testing Gregor v. Bochmann and software testing methods would be adequate for the testing of communication protocols. The purpose

  13. A search for optical variability of type 2 quasars in SDSS stripe 82

    SciTech Connect (OSTI)

    Barth, Aaron J.; Carson, Daniel J.; Voevodkin, Alexey

    2014-01-01

    Hundreds of Type 2 quasars have been identified in Sloan Digital Sky Survey (SDSS) data, and there is substantial evidence that they are generally galaxies with highly obscured central engines, in accord with unified models for active galactic nuclei (AGNs). A straightforward expectation of unified models is that highly obscured Type 2 AGNs should show little or no optical variability on timescales of days to years. As a test of this prediction, we have carried out a search for variability in Type 2 quasars in SDSS Stripe 82 using difference-imaging photometry. Starting with the Type 2 AGN catalogs of Zakamska et al. and Reyes et al., we find evidence of significant g-band variability in 17 out of 173 objects for which light curves could be measured from the Stripe 82 data. To determine the nature of this variability, we obtained new Keck spectropolarimetry observations for seven of these variable AGNs. The Keck data show that these objects have low continuum polarizations (p ? 1% in most cases) and all seven have broad H? and/or Mg II emission lines in their total (unpolarized) spectra, indicating that they should actually be classified as Type 1 AGNs. We conclude that the primary reason variability is found in the SDSS-selected Type 2 AGN samples is that these samples contain a small fraction of Type 1 AGNs as contaminants, and it is not necessary to invoke more exotic possible explanations such as a population of 'naked' or unobscured Type 2 quasars. Aside from misclassified Type 1 objects, the Type 2 quasars do not generally show detectable optical variability over the duration of the Stripe 82 survey.

  14. Translaminar fracture toughness test methods and results from interlaboratory tests of carbon/epoxy laminates

    SciTech Connect (OSTI)

    Underwood, J.H.; Kortschot, M.T.; Lloyd, W.R.; Eidinoff, H.L.; Wilson, D.A.; Ashbaugh, N.

    1995-12-31

    Fracture tests were performed with carbon/polymer laminates and analyzed for the purpose of developing translaminar fracture toughness test and analysis procedures. Notched specimens were tested of two types of symmetrical layups--quasi-isotropic [0/45/90] and [0/90]; two carbon fiber/epoxy materials--a relatively brittle T300 fiber/976 epoxy and a tougher AS4 fiber/977-2 epoxy; two laminate thicknesses--2 mm and 4 mm; and three specimen configurations--the standard three-point bend and compact configurations, and an extended compact specimen with arm-height to specimen-width ratio of 1.9. Stress and displacement expressions were obtained for the extended compact specimen, including those for stress intensity factor, K, and crack mouth opening displacement, V, in terms of relative notch length, a/W, and for a/W in terms of V. Relationships for the bending stresses that control self-similar and off-axis cracking for the extended compact specimen were derived.

  15. Guidelines for Participation in the ETV ESTE Verification Test of Lead Paint Test Kits

    E-Print Network [OSTI]

    Guidelines for Participation in the ETV ESTE Verification Test of Lead Paint Test Kits Revised 09 in the ETV ESTE verification test of lead paint test kits. Test kits must conform to the following guidelines as part of the ETV verification test of lead paint test kits. Testing is scheduled to start by November

  16. Technical bases to consider for performance and demonstration testing of space fission reactors

    SciTech Connect (OSTI)

    Hixson, L. L. (Laurie L.); Houts, M. G. (Michael G.); Clement, S. D. (Steven D.)

    2004-01-01

    Performance and demonstration testing are critical to the success of a space fission reactor program. However, the type and extent to which testing of space reactors should be performed has been a point of discussion within the industry for many years. With regard to full power ground nuclear tests, questions such as: (1) Do the benefits outweigh the risks; (2) Are there equivalent alternatives; (3) Can a test facility be constructed (or modified) in a reasonable amount of time; (4) Will the test article accurately represent the flight system; and (5) Are the costs too restrictive, have been debated for decades. There are obvious benefits of full power ground nuclear testing such as obtaining systems integrated reliability data on a full-scale, complete end-to-end system. But these benefits come at some programmatic risk. In addition, this type of testing does not address safety related issues. This paper will discuss and assess these and other technical considerations essential in deciding which type of performance and demonstration testing to conduct on space fission reactor systems.

  17. Test Two: The ‘Controlled Fire’ 

    E-Print Network [OSTI]

    Cowlard, Adam; Steinhaus, Thomas; Abecassis Empis, Cecilia; Torero, Jose L

    2007-11-14

    The main objective of Test Two was to demonstrate the effectiveness of ventilation changes and smoke management on the growth of a compartment fire and to display the potential for these techniques to be incorporated ...

  18. CCstar and 40gige testing

    SciTech Connect (OSTI)

    fields,parks

    2012-06-29

    This talk covers outlines the history of PaScalbb and then proceeds to outline testing that we need/want to do in order to design future HPC networks here at LANL.

  19. Testing Closeness of Discrete Distributions

    E-Print Network [OSTI]

    Fortnow, Lance

    Given samples from two distributions over an n-element set, we wish to test whether these distributions are statistically close. We present an algorithm which uses sublinear in n, specifically, O(n[superscript 2/3]?[superscript ...

  20. Neutron beam testing of triblades

    SciTech Connect (OSTI)

    Michalak, Sarah E [Los Alamos National Laboratory; Du Bois, Andrew J [Los Alamos National Laboratory; Storlie, Curtis B [Los Alamos National Laboratory; Rust, William N [Los Alamos National Laboratory; Du Bois, David H [Los Alamos National Laboratory; Modl, David G [Los Alamos National Laboratory; Quinn, Heather M [Los Alamos National Laboratory; Blanchard, Sean P [Los Alamos National Laboratory; Manuzzato, Andrea [UNIV DEGLI STUDI DI PADOVA ITALY

    2011-01-31

    PowerXCell 8i processors and Opterons in four IBM Triblades were tested at LANSCE. The hazard rate when the beam was aimed at the Opterons was higher than when it was aimed at the Cell processors.

  1. SOIL TEST INTERPRETATIONS RECOMMENDATIONS HANDBOOK

    E-Print Network [OSTI]

    Noble, James S.

    1 SOIL TEST INTERPRETATIONS AND RECOMMENDATIONS HANDBOOK Originally written 1983 By Daryl D..................................................20 SOIL ACIDITY AND LIMESTONE...............................................27 EXCHANGEABLE MAGNESIUM No. Page No. I. Nitrogen rate adjustments based upon soil texture, organic matter, and time of major

  2. Transition-fault test generation 

    E-Print Network [OSTI]

    Cobb, Bradley Douglas

    2013-02-22

    After an integrated circuit is manufactured, it must be tested to insure that it is not defective. Specifically, timing defects are becoming increasingly important to detect because of the decreasing process geometries and increasing clock rates...

  3. Uniqueness theorems for equations of Keldysh Type

    E-Print Network [OSTI]

    Thomas H. Otway

    2010-05-25

    A fundamental result that characterizes elliptic-hyperbolic equations of Tricomi type, the uniqueness of classical solutions to the open Dirichlet problem, is extended to a large class of elliptic-hyperbolic equations of Keldysh type. The result implies the non-existence of classical solutions to the closed Dirichlet problem for this class of equations. A uniqueness theorem is also proven for a mixed Dirichlet-Neumann problem. A generalized uniqueness theorem for the adjoint operator leads to the existence of distribution solutions to the closed Dirichlet problem in a special case.

  4. Fiber-type dosimeter with improved illuminator

    DOE Patents [OSTI]

    Fox, R.J.

    1985-12-23

    A single-piece, molded plastic, Cassigrainian-type condenser arrangement is incorporated in a tubular-shaped personal pocket dosimeter of the type which combines an ionization chamber with an optically-read fiber electrometer to provide improved illumination of the electrometer fiber. The condenser routes incoming light from one end of the dosimeter tubular housing around a central axis charging pin assembly and focuses the light at low angles to the axis so that it falls within the acceptance angle of the electrometer fiber objective lens viewed through an eyepiece lens disposed in the opposite end of the dosimeter. This results in improved fiber illumination and fiber image contrast.

  5. Fiber-type dosimeter with improved illuminator

    DOE Patents [OSTI]

    Fox, Richard J. (Oak Ridge, TN)

    1987-01-01

    A single-piece, molded plastic, Cassigrainian-type condenser arrangement is incorporated in a tubular-shaped personal pocket dosimeter of the type which combines an ionization chamber with an optically-read fiber electrometer to provide improved illumination of the electrometer fiber. The condenser routes incoming light from one end of the dosimeter tubular housing around a central axis charging pin assembly and focuses the light at low angles to the axis so that it falls within the acceptance angle of the electrometer fiber objective lens viewed through an eyepiece lens disposed in the opposite end of the dosimeter. This results in improved fiber illumination and fiber image contrast.

  6. Transformations of $W$-Type Entangled States

    E-Print Network [OSTI]

    S. K?nta?; S. Turgut

    2010-03-10

    The transformations of $W$-type entangled states by using local operations assisted with classical communication are investigated. For this purpose, a parametrization of the $W$-type states which remains invariant under local unitary transformations is proposed and a complete characterization of the local operations carried out by a single party is given. These are used for deriving the necessary and sufficient conditions for deterministic transformations. A convenient upper bound for the maximum probability of distillation of arbitrary target states is also found.

  7. Property:Water Type | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmental Jump to:EA EIS Report Url JumpTechnology Jump to: navigation,TypeOfType Jump to:

  8. Testing quantum physics in space using optically trapped nanospheres

    E-Print Network [OSTI]

    Rainer Kaltenbaek

    2013-07-26

    Recent developments in space technology like micro-propulsion systems for drag-free control, thermal shielding, ultra-stable laser sources and stable optical cavities set an ideal platform for quantum optomechanical experiments with optically trapped dielectric spheres. Here, we will provide an overview of the results of recent studies aiming at the realization of the space mission MAQRO to test the foundations of quantum physics in a parameter regime orders of magnitude beyond existing experiments. In particular, we will discuss DECIDE, which is an experiment to prepare and then study a Schr\\"odinger-cat-type state, where a dielectric nanosphere of around 100nm radius is prepared in a superposition of being in two clearly distinct positions at the same time. This superposition leads to double-slit-type interference, and the visibility of the interference pattern will be compared to the predictions of quantum theory. This approach allows for testing for possible deviations from quantum theory as our test objects approach macroscopic dimensions. With DECIDE, it will be possible to distinctly test several prominent theoretical models that predict such deviations, for example: the Di\\'osi-Pensrose model, the continuous-spontaneous-localization model of Ghirardi, Rimini, Weber and Pearle, and the model of K\\'arolyh\\'azy.

  9. Thermal well-test method

    DOE Patents [OSTI]

    Tsang, Chin-Fu (Albany, CA); Doughty, Christine A. (Berkeley, CA)

    1985-01-01

    A well-test method involving injection of hot (or cold) water into a groundwater aquifer, or injecting cold water into a geothermal reservoir. By making temperature measurements at various depths in one or more observation wells, certain properties of the aquifer are determined. These properties, not obtainable from conventional well test procedures, include the permeability anisotropy, and layering in the aquifer, and in-situ thermal properties. The temperature measurements at various depths are obtained from thermistors mounted in the observation wells.

  10. Self-testing graph states

    E-Print Network [OSTI]

    Matthew McKague

    2010-10-11

    We give a construction for a self-test for any connected graph state. In other words, for each connected graph state we give a set of non-local correlations that can only be achieved (quantumly) by that particular graph state and certain local measurements. The number of correlations considered is small, being linear in the number of vertices in the graph. We also prove robustness for the test.

  11. Infrastructure Support for Controlled Experimentation with Software Testing and Regression Testing Techniques

    E-Print Network [OSTI]

    Do, Hyunsook

    Infrastructure Support for Controlled Experimentation with Software Testing and Regression Testing@cse.unl.edu January 18, 2004 Abstract Where the development, understanding, and assessment of software testing infrastructure to support controlled experimentation with software testing and regression testing techniques

  12. Infrastructure Support for Controlled Experimentation with Software Testing and Regression Testing Techniques

    E-Print Network [OSTI]

    Do, Hyunsook

    Infrastructure Support for Controlled Experimentation with Software Testing and Regression Testing@cse.unl.edu April 13, 2005 Abstract Where the development, understanding, and assessment of software testing infrastructure to support controlled experimentation with software testing and regression testing techniques

  13. Binary module test. Final report

    SciTech Connect (OSTI)

    Schilling, J.R.; Colley, T.C.; Pundyk, J.

    1980-12-01

    The objective of this project was to design and test a binary loop module representative of and scaleable to commercial size units. The design was based on state-of-the-art heat exchanger technology, and the purpose of the tests was to confirm performance of a supercritical boiling cycle using isobutane and a mixture of isobutane and isopentane as the secondary working fluid. The module was designed as one percent of a 50 MW unit. It was installed at Magma Power's East Mesa geothermal field and tested over a period of approximately 4 months. Most of the test runs were with isobutane but some data were collected for hydrocarbon mixtures. The results of the field tests are reported. In general these results indicate reasonably good heat balances and agreement with overall heat transfer coefficients calculated by current stream analysis methods and available fluid property data; however, measured pressure drops across the heat exchangers were 20 percent higher than estimated. System operation was stable under all conditions tested.

  14. FAFCO Ice Storage test report

    SciTech Connect (OSTI)

    Stovall, T.K.

    1993-11-01

    The Ice Storage Test Facility (ISTF) is designed to test commercial ice storage systems. FAFCO provided a storage tank equipped with coils designed for use with a secondary fluid system. The FAFCO ice storage system was tested over a wide range of operating conditions. Measured system performance during charging showed the ability to freeze the tank fully, storing from 150 to 200 ton-h. However, the charging rate showed significant variations during the latter portion of the charge cycle. During discharge cycles, the storage tank outlet temperature was strongly affected by the discharge rate and tank state of charge. The discharge capacity was dependent upon both the selected discharge rate and maximum allowable tank outlet temperature. Based on these tests, storage tank selection must depend on both charge and discharge conditions. This report describes FAFCO system performance fully under both charging and discharging conditions. While the test results reported here are accurate for the prototype 1990 FAFCO Model 200, currently available FAFCO models incorporate significant design enhancements beyond the Model 200. At least one major modification was instituted as a direct result of the ISTF tests. Such design improvements were one of EPRI`s primary goals in founding the ISTF.

  15. Dynamic Testing of Gasifier Refractory

    SciTech Connect (OSTI)

    Michael D. Mann; Devdutt Shukla; Xi Hong; John P. Hurley

    2004-09-27

    The University of North Dakota (UND) Chemical Engineering Department in conjunction with the UND Energy & Environmental Research Center (EERC) have initiated a program to thoroughly examine the combined chemical (reaction and phase change) and physical (erosion) effects experienced by a variety of refractory materials during both normal operation and thermal cycling under slagging coal gasification conditions. The goal of this work is to devise a mechanism of refractory loss under these conditions. The controlled-atmospheric dynamic corrodent application furnace (CADCAF) is being utilized to simulate refractory/slag interactions under dynamic conditions that more realistically simulate the environment in a slagging coal gasifier than any of the static tests used previously by refractory manufacturers and researchers. Shakedown testing of the CADCAF has been completed. Samples of slag and refractory from the Tampa Electric Polk Power Station have been obtained for testing in the CADCAF. The slag has been dried and sieved to the size needed for our flowing slag corrosion tests. Screening tests are in currently in progress. Detailed analysis of corrosion rates from the first tests is in progress.

  16. Field tests of carbon monitoring methods in forestry projects

    SciTech Connect (OSTI)

    NONE

    1999-07-01

    In response to the emerging scientific consensus on the facts of global climate change, the international Joint Implementation (JI) program provided a pilot phase in which utilities and other industries could finance, among other activities, international efforts to sequester carbon dioxide, a major greenhouse gas. To make JI and its successor mechanisms workable, however, cost-effective methods are needed for monitoring progress in the reduction of greenhouse gas emissions. The papers in this volume describe field test experiences with methods for measuring carbon storage by three types of land use: natural forest, plantation forest, and agroforestry. Each test, in a slightly different land-use situation, contributes to the knowledge of carbon-monitoring methods as experienced in the field. The field tests of the agroforestry guidelines in Guatemala and the Philippines, for example, suggested adaptations in terms of plot size and method of delineating the total area for sampling.

  17. Municipal solid waste combustion: Fuel testing and characterization

    SciTech Connect (OSTI)

    Bushnell, D.J.; Canova, J.H.; Dadkhah-Nikoo, A.

    1990-10-01

    The objective of this study is to screen and characterize potential biomass fuels from waste streams. This will be accomplished by determining the types of pollutants produced while burning selected municipal waste, i.e., commercial mixed waste paper residential (curbside) mixed waste paper, and refuse derived fuel. These materials will be fired alone and in combination with wood, equal parts by weight. The data from these experiments could be utilized to size pollution control equipment required to meet emission standards. This document provides detailed descriptions of the testing methods and evaluation procedures used in the combustion testing and characterization project. The fuel samples will be examined thoroughly from the raw form to the exhaust emissions produced during the combustion test of a densified sample.

  18. Double shell slurry low-temperature corrosion tests

    SciTech Connect (OSTI)

    Divine, J.R.; Bowen, W.M.; McPartland, S.A.; Elmore, R.P.; Engel, D.W.

    1983-09-01

    A series of year-long tests have been completed on potential double shell slurry (DSS) compositions at temperatures up to 100/sup 0/C. These tests have sought data on uniform corrosion, pitting, and stress-corrosion cracking. No indication of the latter two types of corrosion were observed within the test matrix. Corrosion rates after four months were generally below the 1 mpy (25 ..mu..m/y) design limit. By the end of twelve months all results were below this limit and, except for very concentrated mixtures, all were below 0.5 mpy. Prediction equations were generated from a model fitted to the data. The equations provide a rapid means of estimating the corrosion rate for proposed DSS compositions.

  19. Generic Programming With Dependent Types: I Generic Programming in Agda

    E-Print Network [OSTI]

    Weirich, Stephanie

    -typed languages? #12;Why study generic programming in dependently-typed languages? 1 Dependently-typed languages programming in dependently-typed languages? 1 Dependently-typed languages are current research topic and likely component of next-generation languages. 2 Generic programming is a killer-app for dependently

  20. [Type text] Page 1 of 13

    E-Print Network [OSTI]

    Nicholson, Bruce J.

    [Type text] Page 1 of 13 Nguyen, C, April 10, 2009 School of Health Professions Faculty Government BYLAWS OF THE SCHOOL OF HEALTH PROFESSIONS THE UNIVERSITY OF TEXAS HEALTH SCIENCE CENTER AT SAN be the School of Health Professions Faculty Assembly and the School of Health Professions Faculty Council

  1. mathematics Study program cycle and type

    E-Print Network [OSTI]

    ?umer, Slobodan

    mathematics academic study programmm 11 #12;12 #12;· Study program cycle and type: First cycle academic study program. · AAnnttiicciippaatteedd aaccaaddeemmiicc ttiittllee:: Bachelor in Mathematics ggooaallss:: The principal goal of the academic study program in Mathematics is to qualify its graduates

  2. Reference Buildings by Building Type: Primary school

    Broader source: Energy.gov [DOE]

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  3. A Certified Type-Preserving Compiler

    E-Print Network [OSTI]

    Chlipala, Adam

    1 A Certified Type- Preserving Compiler from Lambda Calculus to Assembly Language Adam Chlipala University of California, Berkeley PLDI 2007 #12;2 Why Certified Compilers? Source Code Manual Code Auditing Static Analysis Formal Methods How do we know that these programs have the same behavior? Compiled

  4. Reference Buildings by Building Type: Large office

    Office of Energy Efficiency and Renewable Energy (EERE)

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  5. Reference Buildings by Building Type: Medium office

    Office of Energy Efficiency and Renewable Energy (EERE)

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  6. Reference Buildings by Building Type: Small office

    Office of Energy Efficiency and Renewable Energy (EERE)

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  7. Termination Checking with Types Strong Normalization for

    E-Print Network [OSTI]

    Abel, Andreas

    Termination Checking with Types Strong Normalization for Mendler­Style Course­Of­Value Recursion can be separated into two parts: As the first step, partial correctness is established by verifying that a program matches its specification; then, termination is shown to obtain full correctness. For practical

  8. Termination Checking with Types Strong Normalization for

    E-Print Network [OSTI]

    Abel, Andreas

    Termination Checking with Types Strong Normalization for Mendler-Style Course-Of-Value Recursion can be separated into two parts: As the first step, partial correctness is established by verifying that a program matches its specification; then, termination is shown to obtain full correctness. For practical

  9. Reference Buildings by Building Type: Small Hotel

    Office of Energy Efficiency and Renewable Energy (EERE)

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  10. Reference Buildings by Building Type: Midrise Apartment

    Office of Energy Efficiency and Renewable Energy (EERE)

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  11. Reference Buildings by Building Type: Secondary school

    Office of Energy Efficiency and Renewable Energy (EERE)

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  12. Reference Buildings by Building Type: Warehouse

    Office of Energy Efficiency and Renewable Energy (EERE)

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  13. Reference Buildings by Building Type: Supermarket

    Office of Energy Efficiency and Renewable Energy (EERE)

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  14. Reference Buildings by Building Type: Large Hotel

    Office of Energy Efficiency and Renewable Energy (EERE)

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  15. Reference Buildings by Building Type: Strip mall

    Office of Energy Efficiency and Renewable Energy (EERE)

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  16. Reference Buildings by Building Type: Hospital

    Office of Energy Efficiency and Renewable Energy (EERE)

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  17. Fiber type, meal frequency and colonic cytokinetics 

    E-Print Network [OSTI]

    Zhang, Jianhu

    1993-01-01

    . In vivo cell proliferation was measured by [3H]-thymidine incorporation into DNA. Luminal SCFAs were determined by gas chromatography. ber t e. The pectin and oat bran diets produced higher concentrations of all types of SCFAs and of total SCFA than did...

  18. Testing existing software for safety-related applications. Revision 7.1

    SciTech Connect (OSTI)

    Scott, J.A.; Lawrence, J.D.

    1995-12-01

    The increasing use of commercial off-the-shelf (COTS) software products in digital safety-critical applications is raising concerns about the safety, reliability, and quality of these products. One of the factors involved in addressing these concerns is product testing. A tester`s knowledge of the software product will vary, depending on the information available from the product vendor. In some cases, complete source listings, program structures, and other information from the software development may be available. In other cases, only the complete hardware/software package may exist, with the tester having no knowledge of the internal structure of the software. The type of testing that can be used will depend on the information available to the tester. This report describes six different types of testing, which differ in the information used to create the tests, the results that may be obtained, and the limitations of the test types. An Annex contains background information on types of faults encountered in testing, and a Glossary of pertinent terms is also included. This study is pertinent for safety-related software at reactors.

  19. Rates and progenitors of type Ia supernovae

    SciTech Connect (OSTI)

    Wood-Vasey, William Michael

    2004-08-16

    The remarkable uniformity of Type Ia supernovae has allowed astronomers to use them as distance indicators to measure the properties and expansion history of the Universe. However, Type Ia supernovae exhibit intrinsic variation in both their spectra and observed brightness. The brightness variations have been approximately corrected by various methods, but there remain intrinsic variations that limit the statistical power of current and future observations of distant supernovae for cosmological purposes. There may be systematic effects in this residual variation that evolve with redshift and thus limit the cosmological power of SN Ia luminosity-distance experiments. To reduce these systematic uncertainties, we need a deeper understanding of the observed variations in Type Ia supernovae. Toward this end, the Nearby Supernova Factory has been designed to discover hundreds of Type Ia supernovae in a systematic and automated fashion and study them in detail. This project will observe these supernovae spectrophotometrically to provide the homogeneous high-quality data set necessary to improve the understanding and calibration of these vital cosmological yardsticks. From 1998 to 2003, in collaboration with the Near-Earth Asteroid Tracking group at the Jet Propulsion Laboratory, a systematic and automated searching program was conceived and executed using the computing facilities at Lawrence Berkeley National Laboratory and the National Energy Research Supercomputing Center. An automated search had never been attempted on this scale. A number of planned future large supernovae projects are predicated on the ability to find supernovae quickly, reliably, and efficiently in large datasets. A prototype run of the SNfactory search pipeline conducted from 2002 to 2003 discovered 83 SNe at a final rate of 12 SNe/month. A large, homogeneous search of this scale offers an excellent opportunity to measure the rate of Type Ia supernovae. This thesis presents a new method for analyzing the true sensitivity of a multi-epoch supernova search and finds a Type Ia supernova rate from z {approx} 0.01-0.1 of r{sub V} = 4.26{sub -1.93 -0.10}{sup +1.39 +0.10} h{sup 3} x 10{sup -4} SNe Ia/yr/Mpc{sup 3} from a preliminary analysis of a subsample of the SNfactory prototype search. Several unusual supernovae were found in the course of the SNfactory prototype search. One in particular, SN 2002ic, was the first SN Ia to exhibit convincing evidence for a circumstellar medium and offers valuable insight into the progenitors of Type Ia supernovae.

  20. RestorationFoodTypeTypeCategoryVarietyNameScientificNameRarityStatesFoodshed FishAtikamig

    E-Print Network [OSTI]

    Sprott, Julien Clinton

    RestorationFoodTypeTypeCategoryVarietyNameScientificNameRarityStatesFoodshed FishAtikamig Anishinaabeg WhitefishandroeTGreatLakes FishBass Californiablack seaStereolepisgigasEBCN,BCS,CA,SONMediterraneanCalifornia FishCharBulltroutSalvelinusconfluentusT AK,YT,BC,WA,OR,ID, MT,NV PacificNorthwest,GreatBasinand Rockies