National Library of Energy BETA

Sample records for type incandescent fluorescent

  1. A Bright Idea: New Efficiency Standards for Incandescent and Fluorescent

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Lights | Department of Energy A Bright Idea: New Efficiency Standards for Incandescent and Fluorescent Lights A Bright Idea: New Efficiency Standards for Incandescent and Fluorescent Lights July 21, 2009 - 5:18pm Addthis John Lippert Pretty soon, lighting is going to get a lot more efficient. New standards for incandescent reflector bulbs, general purpose fluorescent bulbs, and regular incandescent bulbs are going into effect beginning in approximately three years. You may be curious about

  2. CALiPER Benchmark Report: Performance of Incandescent A Type and Decorative Lamps and LED Replacements

    SciTech Connect (OSTI)

    Lingard, R. D.; Myer, M. A.; Paget, M. L.

    2008-11-01

    This benchmark report addresses common omnidirectional incandescent lamps - A-type and small decorative, candelabra-type lamps - and their commercially available light-emitting diode (LED) replacements.

  3. Incandescent Lighting | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Lighting » Incandescent Lighting Incandescent Lighting Incandescent lighting is the most common, and least energy efficient, type of lighting used in homes. | Photo courtesy of ©iStockphoto/TokenPhoto. Incandescent lighting is the most common, and least energy efficient, type of lighting used in homes. | Photo courtesy of ©iStockphoto/TokenPhoto. Incandescent lamps are often considered the least energy efficient type of electric lighting commonly found in residential buildings. Although

  4. ,,,"Incandescent","Standard Fluorescent","Compact Fluorescent","High-Intensity Discharge","Halogen"

    U.S. Energy Information Administration (EIA) Indexed Site

    B39. Lighting Equipment, Floorspace, 1999" ,"Total Floorspace (million square feet)" ,"All Buildings","All Lit Buildings","Lighting Equipment (more than one may apply)" ,,,"Incandescent","Standard Fluorescent","Compact Fluorescent","High-Intensity Discharge","Halogen" "All Buildings ................",67338,64321,38156,60344,20666,19223,17926 "Building Floorspace" "(Square

  5. ,,,"Incandescent","Standard Fluorescent","Compact Fluorescent","High-Intensity Discharge","Halogen"

    U.S. Energy Information Administration (EIA) Indexed Site

    8. Lighting Equipment, Number of Buildings, 1999" ,"Number of Buildings (thousand)" ,"All Buildings","All Lit Buildings","Lighting Equipment (more than one may apply)" ,,,"Incandescent","Standard Fluorescent","Compact Fluorescent","High-Intensity Discharge","Halogen" "All Buildings ................",4657,4172,2193,3778,607,430,572 "Building Floorspace" "(Square Feet)"

  6. 2014-04-11 Issuance: Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps; Notice of Proposed Rulemaking

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register notice of proposed rulemaking regarding energy conservation standards for general service fluorescent lamps and incandescent reflectors lamps, as issued by the Assistant Secretary for Energy Efficiency and Renewable Energy on April 11, 2014.

  7. Incandescent Lighting | Department of Energy

    Office of Environmental Management (EM)

    courtesy of iStockphotoTokenPhoto. Incandescent lamps are often considered the least energy efficient type of electric lighting commonly found in residential buildings....

  8. Types of Lighting | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    selection. Types of lighting include: Fluorescent Incandescent Outdoor solar Light-emitting diode (LED) Also learn how energy-efficient lightbulbs compare to traditional...

  9. Photonically Engineered Incandescent Emitter

    DOE Patents [OSTI]

    Gee, James M.; Lin, Shawn-Yu; Fleming, James G.; Moreno, James B.

    2005-03-22

    A photonically engineered incandescence is disclosed. The emitter materials and photonic crystal structure can be chosen to modify or suppress thermal radiation above a cutoff wavelength, causing the emitter to selectively emit in the visible and near-infrared portions of the spectrum. An efficient incandescent lamp is enabled thereby. A method for fabricating a three-dimensional photonic crystal of a structural material, suitable for the incandescent emitter, is also disclosed.

  10. Photonically engineered incandescent emitter

    DOE Patents [OSTI]

    Gee, James M.; Lin, Shawn-Yu; Fleming, James G.; Moreno, James B.

    2003-08-26

    A photonically engineered incandescence is disclosed. The emitter materials and photonic crystal structure can be chosen to modify or suppress thermal radiation above a cutoff wavelength, causing the emitter to selectively emit in the visible and near-infrared portions of the spectrum. An efficient incandescent lamp is enabled thereby. A method for fabricating a three-dimensional photonic crystal of a structural material, suitable for the incandescent emitter, is also disclosed.

  11. High efficiency incandescent lighting

    DOE Patents [OSTI]

    Bermel, Peter; Ilic, Ognjen; Chan, Walker R.; Musabeyoglu, Ahmet; Cukierman, Aviv Ruben; Harradon, Michael Robert; Celanovic, Ivan; Soljacic, Marin

    2014-09-02

    Incandescent lighting structure. The structure includes a thermal emitter that can, but does not have to, include a first photonic crystal on its surface to tailor thermal emission coupled to, in a high-view-factor geometry, a second photonic filter selected to reflect infrared radiation back to the emitter while passing visible light. This structure is highly efficient as compared to standard incandescent light bulbs.

  12. Fluorescent Lighting | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Electricity & Fuel » Lighting » Fluorescent Lighting Fluorescent Lighting Fluorescent Lighting Fluorescent lamps use 25%-35% of the energy used by incandescent products to provide a similar amount of light. They also last about 10 times longer (7,000-24,000 hours). The two general types of fluorescent lamps are: Compact fluorescent lamps (CFLs) -- commonly found with integral ballasts and screw bases, these are popular lamps often used in household fixtures Fluorescent tube and circline

  13. Laser-induced incandescence (LII)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    induced incandescence (LII) - Sandia Energy Energy Search Icon Sandia Home Locations Contact Us Employee Locator Energy & Climate Secure & Sustainable Energy Future Stationary Power Energy Conversion Efficiency Solar Energy Wind Energy Water Power Supercritical CO2 Geothermal Natural Gas Safety, Security & Resilience of the Energy Infrastructure Energy Storage Nuclear Power & Engineering Grid Modernization Battery Testing Nuclear Energy Defense Waste Management Programs Advanced

  14. Energy-Saving Incandescents | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    lightbulbs - high-resolution EPS (2.15 MB) More Documents & Publications Energy-Saving Incandescents CFL Lightbulbs CFL Lightbulbs

  15. Incandescent Lighting Basics | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Incandescent Lighting Basics Incandescent Lighting Basics August 16, 2013 - 10:00am Addthis Incandescent lamps consist of a wire filament inside a glass bulb that is usually filled with inert gas, and they produce light when an electric current heats the filament to a high temperature. Incandescent lamps have a low efficacy (10-17 lumens per watt) compared with other lighting options-because most of the energy released is in the form of heat rather than light-and a short average operating life

  16. How Energy-Efficient Light Bulbs Compare with Traditional Incandescent...

    Office of Environmental Management (EM)

    Energy-Efficient Light Bulbs Compare with Traditional Incandescents How Energy-Efficient Light Bulbs Compare with Traditional Incandescents November 5, 2014 - 11:39pm Addthis By...

  17. Dual LED/incandescent security fixture

    DOE Patents [OSTI]

    Gauna, Kevin Wayne

    2005-06-21

    A dual LED and incandescent security lighting system uses a hybrid approach to LED illumination. It combines an ambient LED illuminator with a standard incandescent lamp on a motion control sensor. The LED illuminator will activate with the onset of darkness (daylight control) and typically remain on during the course of the night ("always on"). The LED illumination, typically amber, is sufficient to provide low to moderate level lighting coverage to the wall and ground area adjacent to and under the fixture. The incandescent lamp is integrated with a motion control circuit and sensor. When movement in the field of view is detected (after darkness), the incandescent lamp is switched on, providing an increased level of illumination to the area. Instead of an "always on" LED illuminator, the LEDs may also be switched off when the incandescent lamp is switched on.

  18. Fluorescent Lighting | Department of Energy

    Office of Environmental Management (EM)

    - by far the most common form of fluorescent lighting but rarely found in residential buildings -- are much more energy efficient than incandescent lamps and are ideally suited...

  19. Energy-Saving Incandescents | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    lighbulbs - high-resolution JPG (3.85 MB) More Documents & Publications Energy-Saving Incandescents CFL Lightbulbs Which Bulb Is Right for You? (High-Resolution JPG Billboard)

  20. Energy Cost Calculator for Compact Fluorescent Lamps | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Compact Fluorescent Lamps Energy Cost Calculator for Compact Fluorescent Lamps This tool calculates the payback period for your calc retrofit project. Modify the default values to suit your project requirements. Existing incandescent lamp wattage Watts Incandescent lamp cost dollars Incandescent lamp life 1000 hours calc wattage Watts calc cost dollars calc life (6000 hours for moderate use, 10000 hours for high use) 8000 hours Number of lamps in retrofit project Hours operating per week hours

  1. Operating temperatures for a convectively cooled recessed incandescent light fixture

    SciTech Connect (OSTI)

    Yarbrough, D.W.; Toor, I.

    1980-12-01

    Test results are given for the operation of a recessed incandescent light fixture intended for residential use. The fixture is labeled for use in direct contact with attic thermal insulation. Temperature control of the powered fixture is provided by convective heat transfer from the ceiling side of the fixture. The fixture was operated at power levels up to two times the rated power of 75 watts and under thermal insulations up to R-40. In all operating configurations tested the fixture surface in contact with attic insulation was found to be less than 175/sup 0/C. The observed surface temperatures are judged to be safe for operation in contact with loose-fill or batt-type insulations. It was observed that the power leads inside one fixture configuration are exposed to temperatures as high as 168/sup 0/C. The electrical insulation could, therefore, have a limited life. The properties of the internal fixture wiring were not, however, studied in detail.

  2. How Energy-Efficient Light Bulbs Compare with Traditional Incandescents |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Electricity & Fuel » Lighting » How Energy-Efficient Light Bulbs Compare with Traditional Incandescents How Energy-Efficient Light Bulbs Compare with Traditional Incandescents By replacing your home's five most frequently used light fixtures or bulbs with models that have earned the ENERGY STAR, you can save $75 each year. By replacing your home's five most frequently used light fixtures or bulbs with models that have earned the ENERGY STAR, you can save $75 each

  3. Fluorescent Lighting | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    They also last about 10 times longer (7,000-24,000 hours). The two general types of ... Although CFLs cost a bit more than comparable incandescent bulbs, they last 6-15 times as ...

  4. Convection venting lensed reflector-type compact fluorescent lamp system

    DOE Patents [OSTI]

    Pelton, B.A.; Siminovitch, M.

    1997-07-29

    Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures. 12 figs.

  5. Convection venting lensed reflector-type compact fluorescent lamp system

    DOE Patents [OSTI]

    Pelton, Bruce A.; Siminovitch, Michael

    1997-01-01

    Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures.

  6. EA-1911: Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps

    Broader source: Energy.gov [DOE]

    This EA will evaluate the environmental impacts of a proposal to amend energy conservation standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps.

  7. DOE Publishes Final Rule for the Request for Exclusion of 100 Watt R20 Short Incandescent Reflector Lamps from Energy Conservation Standards

    Broader source: Energy.gov [DOE]

    The Department of Energy has published a final rule regarding the request for exclusion of 100 Watt R20 short incandescent reflector lamps from energy conservation standards.

  8. Effects of repetitive pulsing on multi-kHz planar laser-induced incandescence imaging in laminar and turbulent flames

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Michael, James B.; Venkateswaran, Prabhakar; Shaddix, Christopher R.; Meyer, Terrence R.

    2015-04-08

    Planar laser-induced incandescence (LII) imaging is reported at repetition rates up to 100 kHz using a burst-mode laser system to enable studies of soot formation dynamics in highly turbulent flames. Furthermore, to quantify the accuracy and uncertainty of relative soot volume fraction measurements, the temporal evolution of the LII field in laminar and turbulent flames is examined at various laser operating conditions. Under high-speed repetitive probing, it is found that LII signals are sensitive to changes in soot physical characteristics when operating at high laser fluences within the soot vaporization regime. For these laser conditions, strong planar LII signals aremore » observed at measurement rates up to 100 kHz but are primarily useful for qualitative tracking of soot structure dynamics. However, LII signals collected at lower fluences allow sequential planar measurements of the relative soot volume fraction with a sufficient signal-to-noise ratio at repetition rates of 10–50 kHz. Finally, guidelines for identifying and avoiding the onset of repetitive probe effects in the LII signals are discussed, along with other potential sources of measurement error and uncertainty.« less

  9. Effects of aggregate morphology and size on laser-induced incandescence and scattering from black carbon (mature soot)

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Bambha, Ray P.; Michelsen, Hope A.

    2015-07-03

    We have used a Single-Particle Soot Photometer (SP2) to measure time-resolved laser-induced incandescence (LII) and laser scatter from combustion-generated mature soot with a fractal dimension of 1.88 extracted from a burner. We have also made measurements on restructured mature-soot particles with a fractal dimension of 2.3–2.4. We reproduced the LII and laser-scatter temporal profiles with an energy- and mass-balance model, which accounted for heating of particles passed through a CW-laser beam over laser–particle interaction times of ~10 μs. Furthermore, the results demonstrate a strong influence of aggregate size and morphology on LII and scattering signals. Conductive cooling competes with absorptivemore » heating on these time scales; the effects are reduced with increasing aggregate size and fractal dimension. These effects can lead to a significant delay in the onset of the LII signal and may explain an apparent low bias in the SP2 measurements for small particle sizes, particularly for fresh, mature soot. The results also reveal significant perturbations to the measured scattering signal from LII interference and suggest rapid expansion of the aggregates during sublimation.« less

  10. Quantification of online removal of refractory black carbon using laser-induced incandescence in the single particle soot photometer

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Aiken, Allison C.; McMeeking, Gavin R.; Levin, Ezra J. T.; Dubey, Manvendra K.; DeMott, Paul J.; Kreidenweis, Sonia M.

    2016-04-05

    Refractory black carbon (rBC) is an aerosol that has important impacts on climate and human health. rBC is often mixed with other species, making it difficult to isolate and quantify its important effects on physical and optical properties of ambient aerosol. To solve this measurement challenge, a new method to remove rBC was developed using laser-induced incandescence (LII) by Levin et al. in 2014. Application of the method with the Single Particle Soot Photometer (SP2) is used to determine the effects of rBC on ice nucleating particles (INP). Here, we quantify the efficacy of the method in the laboratory usingmore » the rBC surrogate Aquadag. Polydisperse and mobility-selected samples (100–500 nm diameter, 0.44–36.05 fg), are quantified by a second SP2. Removal rates are reported by mass and number. For the mobility-selected samples, the average percentages removed by mass and number of the original size are 88.9 ± 18.6% and 87.3 ± 21.9%, respectively. Removal of Aquadag is efficient for particles >100 nm mass-equivalent diameter (dme), enabling application for microphysical studies. However, the removal of particles ≤100 nm dme is less efficient. Absorption and scattering measurements are reported to assess its use to isolate brown carbon (BrC) absorption. Scattering removal rates for the mobility-selected samples are >90% on average, yet absorption rates are 53% on average across all wavelengths. Therefore, application to isolate effects of microphysical properties determined by larger sizes is promising, but will be challenging for optical properties. Lastly, the results reported also have implications for other instruments employing internal LII, e.g., the Soot Particle Aerosol Mass Spectrometer (SP-AMS).« less

  11. Fluorescent refrigeration

    DOE Patents [OSTI]

    Epstein, Richard I.; Edwards, Bradley C.; Buchwald, Melvin I.; Gosnell, Timothy R.

    1995-01-01

    Fluorescent refrigeration is based on selective radiative pumping, using substantially monochromatic radiation, of quantum excitations which are then endothermically redistributed to higher energies. Ultimately, the populated energy levels radiatively deexcite emitting, on the average, more radiant energy than was initially absorbed. The material utilized to accomplish the cooling must have dimensions such that the exciting radiation is strongly absorbed, but the fluorescence may exit the material through a significantly smaller optical pathlength. Optical fibers and mirrored glasses and crystals provide this requirement.

  12. Fluorescent refrigeration

    DOE Patents [OSTI]

    Epstein, R.I.; Edwards, B.C.; Buchwald, M.I.; Gosnell, T.R.

    1995-09-05

    Fluorescent refrigeration is based on selective radiative pumping, using substantially monochromatic radiation, of quantum excitations which are then endothermically redistributed to higher energies. Ultimately, the populated energy levels radiatively deexcite emitting, on the average, more radiant energy than was initially absorbed. The material utilized to accomplish the cooling must have dimensions such that the exciting radiation is strongly absorbed, but the fluorescence may exit the material through a significantly smaller optical pathlength. Optical fibers and mirrored glasses and crystals provide this requirement. 6 figs.

  13. Untitled

    Gasoline and Diesel Fuel Update (EIA)

    0. Number of Lights by Bulb Type by Room, 1993 Bulb Type Incandescent Fluorescent Other Room Total Low Medium High Unknown Short Long Compact Halogen Other unknown Total 4,196 431...

  14. Compact Fluorescent Plug-In Ballast-in-a-Socket

    SciTech Connect (OSTI)

    Rebecca Voelker

    2001-12-21

    The primary goal of this program was to develop a ballast system for plug-in CFLs (compact fluorescent lamps) that will directly replace standard metal shell, medium base incandescent lampholders (such as Levition No. 6098) for use with portable lamp fixtures, such as floor, table and desk lamps. A secondary goal was to identify a plug-in CFL that is optimized for use with this ballast. This Plug-in CFL Ballastin-a-Socket system will allow fixture manufacturers to easily manufacture CFL-based high-efficacy portable fixtures that provide residential and commercial consumers with attractive, cost-effective, and energy-efficient fixtures for use wherever portable incandescent fixtures are used today. The advantages of this proposed system over existing CFL solutions are that the fixtures can only be used with high-efficacy CFLs, and they will be more attractive and will have lower life-cycle costs than screw-in or adapter-based CFL retrofit solutions. These features should greatly increase the penetration of CFL's into the North American market. Our work has shown that using integrated circuits it is quite feasible to produce a lamp-fixture ballast of a size comparable to the current Edison-screw 3-way incandescent fixtures. As for price points for BIAS-based fixtures, end-users polled by the Lighting Research Institute at RPI indicated that they would pay as much as an additional $10 for a lamp containing such a ballast. The ballast has been optimized to run with a 26 W amalgam triple biax lamp in the base-down position, yet can accept non-amalgam versions of the lamp. With a few part alterations, the ballast can be produced to support 32 W lamps as well. The ballast uses GE's existing L-Comp[1] power topology in the circuit so that the integrated circuit design would be a design that could possibly be used by other CFL and EFL products with minor modifications. This gives added value by reducing cost and size of not only the BIAS, but also possibly other integral

  15. Fluorescent Nanoparticles for Radiation DetectionFluorescent...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Find More Like This Return to Search Fluorescent Nanoparticles for Radiation DetectionFluorescent Nanoparticles for Radiation Detection Oak Ridge National Laboratory Contact ORNL ...

  16. Adoption of Light-Emitting Diodes in Common Lighting Applications

    SciTech Connect (OSTI)

    Yamada, Mary; Chwastyk, Dan

    2013-05-01

    Report estimating LED energy savings in nine applications where LEDs compete with traditional lighting sources such as incandescent, halogen, high-pressure sodium, and certain types of fluorescent. The analysis includes indoor lamp, indoor luminaire, and outdoor luminaire applications.

  17. PowerPoint Presentation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    41 51 61 INCANDESCENT HALOGEN CFL LED 0 500 1,000 1,500 2,000 2,500 COUNCIL BASELINE MARKET AVERAGE TYPE: CURRENT PRACTICE BASELINE EFFICACY Linear Fluorescent Lamps, 4ft...

  18. Fluorescence detection: SPIE volume 743

    SciTech Connect (OSTI)

    Menzel, E.R.

    1987-01-01

    This book contains proceedings arranged into four sessions. They are: Fluorescence spectroscopic techniques; Fluorescence in analysis and materials characterization; Fluorescence in medicine and biochemistry; and Fluorescence in criminalistics.

  19. EA-1664: Final Environmental Assessment

    Office of Energy Efficiency and Renewable Energy (EERE)

    10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps

  20. Energy 101: Lighting Choices | Department of Energy

    Energy Savers [EERE]

    but with higher efficiencies-so they save you money. Upgrading 15 of the inefficient incandescent light bulbs in your home to energy-saving incandescent, compact fluorescent ...

  1. Sustainable LED Fluorescent Light Replacement Technology

    SciTech Connect (OSTI)

    2011-06-30

    Ilumisys and the National Center for Manufacturing Sciences (NCMS) partnered on a three-year project awarded by the United States (U.S.) Department of Energy (DOE), to quantify the impacts of LED lamps, incandescent lamps and fluorescent benchmark lamps over a product lifecycle – i.e. to develop a sustainable design and manufacturing strategy that addresses product manufacturing, use, recycling and disposal scenarios for LED-based lighting. Based on the knowledge gained from extensive product tear-down studies of fluorescent and screw-in lighting products, lifecycle assessment tools, and accelerated lifecycle testing protocols, an interactive Sustainable LED Design Guide has been developed to aid architectural and lighting designers and engineers in making design decisions that consider three important environmental impacts (greenhouse gas emissions, energy use and mercury emission) across all phases of the life of an LED lighting product. Critical information developed for the lifecycle analysis and product feature comparisons is the useful life of the lighting product as well as its performance. The Design Guide is available at www.ncms.org, and was developed based on operational and durability testing of a variety of lighting products including power consumption, light output, and useful life of a lamp in order to allow a more realistic comparison of lamp designs. This report describes the main project tasks, results and innovative features of the lifecycle assessment (LCA)-based design tools, and the key considerations driving the sustainable design of LED lighting systems. The Design Guide incorporates the following three novel features for efficiently evaluating LED lighting features in value-chains: • Bill-of-Materials (BOM) Builder – Designers may import process data for each component and supply functional data for the product, including power, consumption, lumen output and expected useful life. • Environmental Impact Review – Designs are

  2. Fluorescent optical position sensor

    DOE Patents [OSTI]

    Weiss, Jonathan D.

    2005-11-15

    A fluorescent optical position sensor and method of operation. A small excitation source side-pumps a localized region of fluorescence at an unknown position along a fluorescent waveguide. As the fluorescent light travels down the waveguide, the intensity of fluorescent light decreases due to absorption. By measuring with one (or two) photodetectors the attenuated intensity of fluorescent light emitted from one (or both) ends of the waveguide, the position of the excitation source relative to the waveguide can be determined by comparing the measured light intensity to a calibrated response curve or mathematical model. Alternatively, excitation light can be pumped into an end of the waveguide, which generates an exponentially-decaying continuous source of fluorescent light along the length of the waveguide. The position of a photodetector oriented to view the side of the waveguide can be uniquely determined by measuring the intensity of the fluorescent light emitted radially at that location.

  3. Safe biodegradable fluorescent particles

    DOE Patents [OSTI]

    Martin, Sue I.; Fergenson, David P.; Srivastava, Abneesh; Bogan, Michael J.; Riot, Vincent J.; Frank, Matthias

    2010-08-24

    A human-safe fluorescence particle that can be used for fluorescence detection instruments or act as a safe simulant for mimicking the fluorescence properties of microorganisms. The particle comprises a non-biological carrier and natural fluorophores encapsulated in the non-biological carrier. By doping biodegradable-polymer drug delivery microspheres with natural or synthetic fluorophores, the desired fluorescence can be attained or biological organisms can be simulated without the associated risks and logistical difficulties of live microorganisms.

  4. Incandescent Lighting | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    These lamps produce visible light by heating a tiny coil or filament of tungsten wire that glows when it is heated by an electrical current. "Long-life" lamps are an example of ...

  5. Laser-induced incandescence (LII)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Mountain Gondola to see the amazing views of the mountain and the lake at the top. ... folklore, statistics, landmarks, beaches, movies, and secret sports of Lake Tahoe. ...

  6. Types of Lighting in Commercial Buildings - Lighting Types

    U.S. Energy Information Administration (EIA) Indexed Site

    is termed fluorescence). A ballast is required to regulate and control the current and voltage. Two types of ballasts are used, magnetic and electronic. Electronic ballasts have...

  7. Fluorescent fiber diagnostics

    DOE Patents [OSTI]

    Toeppen, John S.

    1994-10-04

    A fluorescent fiber (13) having a doped core (16) is pumped (11) by light (18) of a relatively short wavelength to produce fluorescence at a longer wavelength that is detected by detector (24). The level of fluorescence is monitored (26) and evaluated to provide information as to the excitation of the fiber (13) or the environment thereof. In particular, the level of intensity of the detected fluorescence may be used to measure the intensity of a light beam (18) passing axially through an optical fiber system (12) (FIG. 1 ), or the intensity of a light beam (46) passing radially through a fluorescent fiber (13) (FIG. 2 ), or the level of a fluid (32) in a tank (31) (FIG. 3 ), or a scintillation event (37) in a fluorescent fiber (13) pumped to produce amplification of the scintillation event (FIG. 4 ).

  8. Fluorescent fiber diagnostics

    DOE Patents [OSTI]

    Toeppen, John S.

    1994-01-01

    A fluorescent fiber (13) having a doped core (16) is pumped (11) by light (18) of a relatively short wavelength to produce fluorescence at a longer wavelength that is detected by detector (24). The level of fluorescence is monitored (26) and evaluated to provide information as to the excitation of the fiber (13) or the environment thereof. In particular, the level of intensity of the detected fluorescence may be used to measure the intensity of a light beam (18) passing axially through an optical fiber system (12) (FIG. 1 ), or the intensity of a light beam (46) passing radially through a fluorescent fiber (13) (FIG. 2 ), or the level of a fluid (32) in a tank (31) (FIG. 3 ), or a scintillation event (37) in a fluorescent fiber (13) pumped to produce amplification of the scintillation event (FIG. 4 ).

  9. Organimetallic Fluorescent Complex Polymers For Light Emitting Applications

    DOE Patents [OSTI]

    Shi, Song Q.; So, Franky

    1997-10-28

    A fluorescent complex polymer with fluorescent organometallic complexes connected by organic chain spacers is utilized in the fabrication of light emitting devices on a substantially transparent planar substrate by depositing a first conductive layer having p-type conductivity on the planar surface of the substrate, depositing a layer of a hole transporting and electron blocking material on the first conductive layer, depositing a layer of the fluorescent complex polymer on the layer of hole transporting and electron blocking material as an electron transporting emissive layer and depositing a second conductive layer having n-type conductivity on the layer of fluorescent complex polymer.

  10. Fluorescent Tube Lamps

    Broader source: Energy.gov [DOE]

    FEMP temporarily suspended its energy efficiency requirements for fluorescent tube lamps as it evaluates the market impact of the pending 2012 minimum efficiency standards for fluorescent lamps. The program will issue updated energy efficiency requirements when the market distribution of this product category stabilizes and when doing so has the potential to result in significant Federal energy savings.

  11. Highly thermostable fluorescent proteins

    DOE Patents [OSTI]

    Bradbury, Andrew M.; Waldo, Geoffrey S.; Kiss, Csaba

    2011-03-22

    Thermostable fluorescent proteins (TSFPs), methods for generating these and other stability-enhanced proteins, polynucleotides encoding such proteins, and assays and method for using the TSFPs and TSFP-encoding nucleic acid molecules are provided. The TSFPs of the invention show extremely enhanced levels of stability and thermotolerance. In one case, for example, a TSFP of the invention is so stable it can be heated to 99.degree. C. for short periods of time without denaturing, and retains 85% of its fluorescence when heated to 80.degree. C. for several minutes. The invention also provides a method for generating stability-enhanced variants of a protein, including but not limited to fluorescent proteins.

  12. Highly thermostable fluorescent proteins

    DOE Patents [OSTI]

    Bradbury, Andrew M.; Waldo, Geoffrey S.; Kiss, Csaba

    2011-11-29

    Thermostable fluorescent proteins (TSFPs), methods for generating these and other stability-enhanced proteins, polynucleotides encoding such proteins, and assays and method for using the TSFPs and TSFP-encoding nucleic acid molecules are provided. The TSFPs of the invention show extremely enhanced levels of stability and thermotolerance. In one case, for example, a TSFP of the invention is so stable it can be heated to 99.degree. C. for short periods of time without denaturing, and retains 85% of its fluorescence when heated to 80.degree. C. for several minutes. The invention also provides a method for generating stability-enhanced variants of a protein, including but not limited to fluorescent proteins.

  13. Highly thermostable fluorescent proteins

    DOE Patents [OSTI]

    Bradbury, Andrew M.; Waldo, Geoffrey S.; Kiss, Csaba

    2012-05-01

    Thermostable fluorescent proteins (TSFPs), methods for generating these and other stability-enhanced proteins, polynucleotides encoding such proteins, and assays and method for using the TSFPs and TSFP-encoding nucleic acid molecules are provided. The TSFPs of the invention show extremely enhanced levels of stability and thermotolerance. In one case, for example, a TSFP of the invention is so stable it can be heated to 99.degree. C. for short periods of time without denaturing, and retains 85% of its fluorescence when heated to 80.degree. C. for several minutes. The invention also provides a method for generating stability-enhanced variants of a protein, including but not limited to fluorescent proteins.

  14. Fluorescent filtered electrophosphorescence

    DOE Patents [OSTI]

    Forrest, Stephen; Sun, Yiru; Giebink, Noel; Thompson, Mark E.

    2010-08-03

    The present invention relates to organic light emitting devices (OLEDs), and more specifically to OLEDS that emit light using a combination of fluorescent emitters and phosphorescent emitters for the efficient utilization of all of the electrically generated excitons.

  15. Fluorescent filtered electrophosphorescence

    DOE Patents [OSTI]

    Forrest, Stephen R.; Sun, Yiru; Giebink, Noel; Thompson, Mark E.

    2009-01-06

    The present invention relates to organic light emitting devices (OLEDs), and more specifically to OLEDS that emit light using a combination of fluorescent emitters and phosphorescent emitters for the efficient utilization of all of the electrically generated excitons.

  16. Recombinant fluorescent protein microsphere calibration standard

    DOE Patents [OSTI]

    Nolan, John P.; Nolan, Rhiannon L.; Ruscetti, Teresa; Lehnert, Bruce E.

    2001-01-01

    A method for making recombinant fluorescent protein standard particles for calibration of fluorescence instruments.

  17. Fluorescent image tracking velocimeter

    DOE Patents [OSTI]

    Shaffer, Franklin D.

    1994-01-01

    A multiple-exposure fluorescent image tracking velocimeter (FITV) detects and measures the motion (trajectory, direction and velocity) of small particles close to light scattering surfaces. The small particles may follow the motion of a carrier medium such as a liquid, gas or multi-phase mixture, allowing the motion of the carrier medium to be observed, measured and recorded. The main components of the FITV include: (1) fluorescent particles; (2) a pulsed fluorescent excitation laser source; (3) an imaging camera; and (4) an image analyzer. FITV uses fluorescing particles excited by visible laser light to enhance particle image detectability near light scattering surfaces. The excitation laser light is filtered out before reaching the imaging camera allowing the fluoresced wavelengths emitted by the particles to be detected and recorded by the camera. FITV employs multiple exposures of a single camera image by pulsing the excitation laser light for producing a series of images of each particle along its trajectory. The time-lapsed image may be used to determine trajectory and velocity and the exposures may be coded to derive directional information.

  18. Electric Power | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    From incandescent bulbs to fluorescents to LEDs, learn more about the long history of the light bulb. From incandescent bulbs to fluorescents to LEDs,...

  19. Simultaneous neuron- and astrocyte-specific fluorescent marking

    SciTech Connect (OSTI)

    Schulze, Wiebke; Hayata-Takano, Atsuko; Kamo, Toshihiko; Nakazawa, Takanobu; Nagayasu, Kazuki; Kasai, Atsushi; Seiriki, Kaoru; Shintani, Norihito; Ago, Yukio; Farfan, Camille; and others

    2015-03-27

    Systematic and simultaneous analysis of multiple cell types in the brain is becoming important, but such tools have not yet been adequately developed. Here, we aimed to generate a method for the specific fluorescent labeling of neurons and astrocytes, two major cell types in the brain, and we have developed lentiviral vectors to express the red fluorescent protein tdTomato in neurons and the enhanced green fluorescent protein (EGFP) in astrocytes. Importantly, both fluorescent proteins are fused to histone 2B protein (H2B) to confer nuclear localization to distinguish between single cells. We also constructed several expression constructs, including a tandem alignment of the neuron- and astrocyte-expression cassettes for simultaneous labeling. Introducing these vectors and constructs in vitro and in vivo resulted in cell type-specific and nuclear-localized fluorescence signals enabling easy detection and distinguishability of neurons and astrocytes. This tool is expected to be utilized for the simultaneous analysis of changes in neurons and astrocytes in healthy and diseased brains. - Highlights: • We develop a method for the specific fluorescent labeling of neurons and astrocytes. • Neuron-specific labeling is achieved using Scg10 and synapsin promoters. • Astrocyte-specific labeling is generated using the minimal GFAP promoter. • Nuclear localization of fluorescent proteins is achieved with histone 2B protein.

  20. Integrated fluorescence analysis system

    DOE Patents [OSTI]

    Buican, Tudor N.; Yoshida, Thomas M.

    1992-01-01

    An integrated fluorescence analysis system enables a component part of a sample to be virtually sorted within a sample volume after a spectrum of the component part has been identified from a fluorescence spectrum of the entire sample in a flow cytometer. Birefringent optics enables the entire spectrum to be resolved into a set of numbers representing the intensity of spectral components of the spectrum. One or more spectral components are selected to program a scanning laser microscope, preferably a confocal microscope, whereby the spectrum from individual pixels or voxels in the sample can be compared. Individual pixels or voxels containing the selected spectral components are identified and an image may be formed to show the morphology of the sample with respect to only those components having the selected spectral components. There is no need for any physical sorting of the sample components to obtain the morphological information.

  1. Magnetic fluorescent lamp

    DOE Patents [OSTI]

    Berman, S.M.; Richardson R.W.

    1983-12-29

    The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly is enhanced by providing means for establishing a magnetic field with lines of force along the path of electron flow through the bulb of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

  2. Laser-Induced Fluorescence

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Induced Fluorescence - Sandia Energy Energy Search Icon Sandia Home Locations Contact Us Employee Locator Energy & Climate Secure & Sustainable Energy Future Stationary Power Energy Conversion Efficiency Solar Energy Wind Energy Water Power Supercritical CO2 Geothermal Natural Gas Safety, Security & Resilience of the Energy Infrastructure Energy Storage Nuclear Power & Engineering Grid Modernization Battery Testing Nuclear Energy Defense Waste Management Programs Advanced Nuclear

  3. Types of Lighting in Commercial Buildings - Changes

    U.S. Energy Information Administration (EIA) Indexed Site

    of lit buildings to more than 20 percent (Figure 17 and Table 5). The use of halogen lamps nearly doubled, from 7 percent to 13 percent of lit buildings. Use of incandescent...

  4. Fluorescent microthermographic imaging

    SciTech Connect (OSTI)

    Barton, D.L.

    1993-09-01

    In the early days of microelectronics, design rules and feature sizes were large enough that sub-micron spatial resolution was not needed. Infrared or IR thermal techniques were available that calculated the object`s temperature from infrared emission. There is a fundamental spatial resolution limitation dependent on the wavelengths of light being used in the image formation process. As the integrated circuit feature sizes began to shrink toward the one micron level, the limitations imposed on IR thermal systems became more pronounced. Something else was needed to overcome this limitation. Liquid crystals have been used with great success, but they lack the temperature measurement capabilities of other techniques. The fluorescent microthermographic imaging technique (FMI) was developed to meet this need. This technique offers better than 0.01{degrees}C temperature resolution and is diffraction limited to 0.3 {mu}m spatial resolution. While the temperature resolution is comparable to that available on IR systems, the spatial resolution is much better. The FMI technique provides better spatial resolution by using a temperature dependent fluorescent film that emits light at 612 nm instead of the 1.5 {mu}m to 12 {mu}m range used by IR techniques. This tutorial starts with a review of blackbody radiation physics, the process by which all heated objects emit radiation to their surroundings, in order to understand the sources of information that are available to characterize an object`s surface temperature. The processes used in infrared thermal imaging are then detailed to point out the limitations of the technique but also to contrast it with the FMI process. The FMI technique is then described in detail, starting with the fluorescent film physics and ending with a series of examples of past applications of FMI.

  5. Fluorescence analyzer for lignin

    DOE Patents [OSTI]

    Berthold, John W.; Malito, Michael L.; Jeffers, Larry

    1993-01-01

    A method and apparatus for measuring lignin concentration in a sample of wood pulp or black liquor comprises a light emitting arrangement for emitting an excitation light through optical fiber bundles into a probe which has an undiluted sensing end facing the sample. The excitation light causes the lignin concentration to produce fluorescent emission light which is then conveyed through the probe to analyzing equipment which measures the intensity of the emission light. Measures a This invention was made with Government support under Contract Number DOE: DE-FC05-90CE40905 awarded by the Department of Energy (DOE). The Government has certain rights in this invention.

  6. Fluorescent temperature sensor

    DOE Patents [OSTI]

    Baker, Gary A [Los Alamos, NM; Baker, Sheila N [Los Alamos, NM; McCleskey, T Mark [Los Alamos, NM

    2009-03-03

    The present invention is a fluorescent temperature sensor or optical thermometer. The sensor includes a solution of 1,3-bis(1-pyrenyl)propane within a 1-butyl-1-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ionic liquid solvent. The 1,3-bis(1-pyrenyl)propane remains unassociated when in the ground state while in solution. When subjected to UV light, an excited state is produced that exists in equilibrium with an excimer. The position of the equilibrium between the two excited states is temperature dependent.

  7. X-ray fluorescence mapping

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    X-Ray Microscopy and Imaging: X-ray Fluorescence Mapping Of increasing scientific interest is the detection, quantification and mapping of elemental content of samples, often down...

  8. Untitled

    U.S. Energy Information Administration (EIA) Indexed Site

    position of the fixture affect the actual output of compact fluorescent bulbs, and the quality of the light may differ between compact fluorescents and incandescents....

  9. Fluorescent fluid interface position sensor

    DOE Patents [OSTI]

    Weiss, Jonathan D.

    2004-02-17

    A new fluid interface position sensor has been developed, which is capable of optically determining the location of an interface between an upper fluid and a lower fluid, the upper fluid having a larger refractive index than a lower fluid. The sensor functions by measurement, of fluorescence excited by an optical pump beam which is confined within a fluorescent waveguide where that waveguide is in optical contact with the lower fluid, but escapes from the fluorescent waveguide where that waveguide is in optical contact with the upper fluid.

  10. Types of Lighting in Commercial Buildings - Table L3

    U.S. Energy Information Administration (EIA) Indexed Site

    Any Lighting Lighted Area Only Area Lit by Each Type of Light Incan- descent Standard Fluor-escent Compact Fluor- escent High Intensity Discharge Halogen All...

  11. Types of Lighting in Commercial Buildings - Table L1

    U.S. Energy Information Administration (EIA) Indexed Site

    Any Lighting Lighted Area Only Area Lit by Each Type of Light Incan- descent Standard Fluor-escent Compact Fluor- escent High Intensity Discharge Halogen All...

  12. Types of Lighting in Commercial Buildings - Table L2

    U.S. Energy Information Administration (EIA) Indexed Site

    Any Lighting Lighted Area Only Area Lit by Each Type of Light Incan- descent Standard Fluor-escent Compact Fluor- escent High Intensity Discharge Halogen All Buildings*...

  13. Fluorescent Lighting Basics | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fluorescent Lighting Basics Fluorescent Lighting Basics October 17, 2013 - 5:39pm Addthis Light from a fluorescent lamp is first created by an electric current conducted through an inert gas producing ultraviolet light that is invisible to the human eye. The ultraviolet light in turn interacts with special blends of phosphors coating the interior surface of the fluorescent lamp tube that efficiently converts the invisible light into useful white light. Fluorescent lamps require a special power

  14. Fluorescent Lighting Basics | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fluorescent Lighting Basics Fluorescent Lighting Basics October 17, 2013 - 5:39pm Addthis Light from a fluorescent lamp is first created by an electric current conducted through an inert gas producing ultraviolet light that is invisible to the human eye. The ultraviolet light in turn interacts with special blends of phosphors coating the interior surface of the fluorescent lamp tube that efficiently converts the invisible light into useful white light. Fluorescent lamps require a special power

  15. Covered Product Category: Fluorescent Luminaires

    Broader source: Energy.gov [DOE]

    FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including fluorescent luminaires. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  16. 2014-12-30 Issuance: Energy Conservation Standard for General Service

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fluorescent Lamps and Incandescent Reflector Lamps; Final Rule | Department of Energy 30 Issuance: Energy Conservation Standard for General Service Fluorescent Lamps and Incandescent Reflector Lamps; Final Rule 2014-12-30 Issuance: Energy Conservation Standard for General Service Fluorescent Lamps and Incandescent Reflector Lamps; Final Rule This document is a pre-publication Federal Register final rule regarding energy conservation standards for general service fluorescent lamps and

  17. Covered Product Category: Fluorescent Luminaires | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Luminaires," using IESNA LM-41, ANSI C82.2-2002 for fluorescent ballasts, and ANSI C78.81-2005 for fluorescent lamps. Finding the Luminaire Efficacy Rating LERs should be...

  18. Long wave fluorophore sensor compounds and other fluorescent sensor compounds in polymers

    DOE Patents [OSTI]

    Walsh, Joseph C.; Heiss, Aaron M.; Noronha, Glenn; Vachon, David J.; Lane, Stephen M.; Satcher, Jr., Joe H.; Peyser, Thomas A.; Van Antwerp, William Peter; Mastrototaro, John Joseph

    2004-07-20

    Fluorescent biosensor molecules, fluorescent biosensors and systems, as well as methods of making and using these biosensor molecules and systems are described. Embodiments of these biosensor molecules exhibit fluorescence emission at wavelengths greater than about 650 nm. Typical biosensor molecules include a fluorophore that includes an iminium ion, a linker moiety that includes a group that is an anilinic type of relationship to the fluorophore and a boronate substrate recognition/binding moiety, which binds glucose. The fluorescence molecules modulated by the presence or absence of polyhydroxylated analytes such as glucose. This property of these molecules of the invention, as well as their ability to emit fluorescent light at greater than about 650 nm, renders these biosensor molecules particularly well-suited for detecting and measuring in-vivo glucose concentrations.

  19. Fluorescent optical liquid level sensor

    DOE Patents [OSTI]

    Weiss, Jonathan D. (Albuquerque, NM)

    2001-01-01

    A liquid level sensor comprising a transparent waveguide containing fluorescent material that is excited by light of a first wavelength and emits at a second, longer wavelength. The upper end of the waveguide is connected to a light source at the first wavelength through a beveled portion of the waveguide such that the input light is totally internally reflected within the waveguide above an air/liquid interface in a tank but is transmitted into the liquid below this interface. Light is emitted from the fluorescent material only in those portions of the waveguide that are above the air/liquid interface, to be collected at the upper end of the waveguide by a detector that is sensitive only to the second wavelength. As the interface moves down in the tank, the signal strength from the detector will increase.

  20. Fluorescence based chemical sensors for corrosion detection

    SciTech Connect (OSTI)

    Johnson, R.E.; Agarwala, V.S.

    1997-12-01

    Several fluorescent materials have been identified as possible corrosion sensing coatings. These are either redox or metal ion complex materials. The redox materials are nonfluorescent in the reduced state and become fluorescent upon oxidation. Incorporated into paint coatings, they provide an early warning of corrosive conditions at the metal or alloy surface. The metal ion complex materials only fluoresce when the organic compound complexes with metal ions such as those generated in corrosion reactions. Fluorescent materials have been incorporated into paint coatings and on metal surfaces for the detection of corrosion. Oxine reacts with aluminum oxide on corroded aluminum to give a fluorescence that can be photographed in UV light. Several other materials were found to have good fluorescence but cannot be reversibly oxidized or reduced at the present time. More work will be done with these compounds as well as with Schiff bases to develop new fluorescent chemical sensing materials for smart coating on alloy surfaces.

  1. Compact fast analyzer of rotary cuvette type

    DOE Patents [OSTI]

    Thacker, Louis H.

    1976-01-01

    A compact fast analyzer of the rotary cuvette type is provided for simultaneously determining concentrations in a multiplicity of discrete samples using either absorbance or fluorescence measurement techniques. A rigid, generally rectangular frame defines optical passageways for the absorbance and fluorescence measurement systems. The frame also serves as a mounting structure for various optical components as well as for the cuvette rotor mount and drive system. A single light source and photodetector are used in making both absorbance and fluorescence measurements. Rotor removal and insertion are facilitated by a swing-out drive motor and rotor mount. BACKGROUND OF THE INVENTION The invention relates generally to concentration measuring instruments and more specifically to a compact fast analyzer of the rotary cuvette type which is suitable for making either absorbance or fluorescence measurements. It was made in the course of, or under, a contract with the U.S. Atomic Energy Commission.

  2. Saccharide sensing molecules having enhanced fluorescent properties

    DOE Patents [OSTI]

    Satcher Jr., Joe H.; Lane, Stephen M.; Darrow, Christopher B.; Cary, Douglas R.; Tran, Joe Anh

    2004-01-06

    The present invention provides formulae for fluorescent compounds that have a number of properties which make them uniquely suited for use in sensors of analytes such as saccharides. The advantageous fluorescent properties include favorable excitation wavelengths, emission wavelengths, fluorescence lifetimes, and photostability. Additional advantageous properties include enhanced aqueous solubility, as well as temperature and pH sensitivity. The compound comprises an aryl or a substituted phenyl botonic acid that acts as a substrate recognition component, a fluorescence switch component, and a fluorophore. Fluorescent compounds are described that are excited at wavelengths greater than 400 nm and emit at wavelengths greater than 450 nm, which is advantageous for optical transmission through skin. The fluorophore is typically selected from transition metal-ligand complexes and thiazine, oxazine, oxazone, or oxazine-one as well as anthracene compounds. The fluorescent compound can be immobilized in a glucose permeable biocompatible polymer matrix that is implantable below the skin.

  3. Chromosome characterization using single fluorescent dye

    DOE Patents [OSTI]

    Crissman, Harry A.; Hirons, Gregory T.

    1995-01-01

    Chromosomes are characterized by fluorescent emissions from a single fluorescent dye that is excited over two different wavelengths. A mixture containing chromosomes is stained with a single dye selected from the group consisting of TOTO and YOYO and the stained chromosomes are placed in a flow cytometer. The fluorescent dye is excited sequentially by a first light having a wavelength in the ultraviolet range to excite the TOTO or YOYO to fluoresce at a first intensity and by a second light having a wavelength effective to excite the TOTO or YOYO dye to fluoresce at a second intensity. Specific chromosomes may be identified and sorted by intensity relationships between the first and second fluorescence emissions.

  4. Scanning fluorescent microthermal imaging apparatus and method

    DOE Patents [OSTI]

    Barton, Daniel L.; Tangyunyong, Paiboon

    1998-01-01

    A scanning fluorescent microthermal imaging (FMI) apparatus and method is disclosed, useful for integrated circuit (IC) failure analysis, that uses a scanned and focused beam from a laser to excite a thin fluorescent film disposed over the surface of the IC. By collecting fluorescent radiation from the film, and performing point-by-point data collection with a single-point photodetector, a thermal map of the IC is formed to measure any localized heating associated with defects in the IC.

  5. Scanning fluorescent microthermal imaging apparatus and method

    DOE Patents [OSTI]

    Barton, D.L.; Tangyunyong, P.

    1998-01-06

    A scanning fluorescent microthermal imaging (FMI) apparatus and method is disclosed, useful for integrated circuit (IC) failure analysis, that uses a scanned and focused beam from a laser to excite a thin fluorescent film disposed over the surface of the IC. By collecting fluorescent radiation from the film, and performing point-by-point data collection with a single-point photodetector, a thermal map of the IC is formed to measure any localized heating associated with defects in the IC. 1 fig.

  6. Buying an Appliance this Holiday Season? ENERGY STAR Products...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Refrigerators Freezers Room air conditioners Televisions Clothes washers Dishwashers Battery chargers Water heaters Fluorescent lamp ballasts Incandescent reflector lamps If your ...

  7. Save Energy With A Picnic! | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    the physical effort it takes to power incandescent, compact fluorescent and LED light bulbs. Students from Churchill Road Elementary School in Virginia recently pedaled for...

  8. APPLIANCE STANDARDS

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Equipment General Service Incandescent Lamps General Service Fluorescent Lamps Small Electric Motors Electric Motors Water Heaters Furnace Fans Distribution Transformers Water...

  9. 2014-04-11 Issuance: Energy Conservation Standards for General...

    Energy Savers [EERE]

    Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps; Notice of Proposed Rulemaking 2014-04-11 Issuance: Energy Conservation ...

  10. Peering into a Quantum Well | U.S. DOE Office of Science (SC...

    Office of Science (SC) Website

    to this potentially energy-saving alternative to conventional incandescent and fluorescent lighting. At issue, in particular, are the blue (and green) nitride-based ...

  11. Fluorescent Optical Position Sensor - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Technologies Find More Like This Return to Search Fluorescent Optical Position Sensor Sandia National Laboratories Contact SNL About This Technology Publications: PDF...

  12. Fermentative Method for Making Nonoxide Fluorescent Nanoparticles...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Fermentative Method for Making Nonoxide Fluorescent Nanoparticles (Quantum Dots) Oak Ridge National Laboratory Contact ORNL About This Technology Incubation of quantum dots...

  13. Optical gating of perylene bisimide fluorescence usingdithienylcyclop...

    Office of Scientific and Technical Information (OSTI)

    The emission of millions of fluorescence photons from a chromophore is controlled by the absorption of a few tens of photons in a photochromic molecule. The parameters that ...

  14. Portable spotter for fluorescent contaminants on surfaces

    DOE Patents [OSTI]

    Schuresko, Daniel D.

    1980-01-01

    A portable fluorescence-based spotter for polynuclear aromatic hydrocarbon contamination on personnel and work area surfaces under ambient lighting conditions is provided. This instrument employs beam modulation and phase sensitive detection for discriminating between fluorescence from organic materials from reflected background light and inorganic fluorescent material. The device uses excitation and emission filters to provide differentiation between classes of aromatic organic compounds. Certain inorganic fluorescent materials, including heavy metal compounds, may also be distinguished from the organic compounds, despite both having similar optical properties.

  15. LED Replacements for Linear Fluorescent Lamps Webcast

    Broader source: Energy.gov [DOE]

    In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting...

  16. National Lighting Energy Consumption

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Lighting Energy National Lighting Energy Consumption Consumption 390 Billion kWh used for lighting in all 390 Billion kWh used for lighting in all commercial buildings in commercial buildings in 2001 2001 LED (<.1% ) Incandescent 40% HID 22% Fluorescent 38% Lighting Energy Consumption by Lighting Energy Consumption by Breakdown of Lighting Energy Breakdown of Lighting Energy Major Sector and Light Source Type Major Sector and Light Source Type Source: Navigant Consulting, Inc., U.S. Lighting

  17. Lighting In the Library: A Student Energy Audit

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Homes & Buildings » Lighting & Daylighting » Lighting Basics Lighting Basics August 15, 2013 - 5:12pm Addthis Text Version There are many different types of artificial lights (formally called "lamps" in the lighting industry,) which have different applications and uses. Types of lighting include: Fluorescent Lighting High-intensity Discharge Lighting Incandescent Lighting LED Lighting. New lamp designs that use energy-efficient technology are now readily available in the

  18. Lighting Basics | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Homes & Buildings » Lighting & Daylighting » Lighting Basics Lighting Basics August 15, 2013 - 5:12pm Addthis Text Version There are many different types of artificial lights (formally called "lamps" in the lighting industry,) which have different applications and uses. Types of lighting include: Fluorescent Lighting High-intensity Discharge Lighting Incandescent Lighting LED Lighting. New lamp designs that use energy-efficient technology are now readily available in the

  19. Applications of Nuclear Resonance Fluorescence

    SciTech Connect (OSTI)

    Warren, Glen A.; Detwiler, Rebecca S.; Peplowski, Patrick N.

    2010-11-11

    Nuclear Resonance Fluorescence (NRF) has the potential of addressing a wide variety of applications, which require isotopic and/or elemental information about a sample. We have investigated a variety of non-proliferation applications that may be addressed by NRF. From these applications, we have selected two, measuring uranium enrichment in UF6 cylinders and material verification in dismantlement, to investigate in more detail. Analytical models have been developed to evaluate these applications, and test measurements have been conducted to validate those models. We found that it is unlikely with current technology to address the requirements for UF6 cylinder enrichment measurements. In contrast, NRF is a very promising approach for material verification for dismantlement.

  20. Fiber optical assembly for fluorescence spectrometry

    DOE Patents [OSTI]

    Carpenter, II, Robert W.; Rubenstein, Richard; Piltch, Martin; Gray, Perry

    2010-12-07

    A system for analyzing a sample for the presence of an analyte in a sample. The system includes a sample holder for containing the sample; an excitation source, such as a laser, and at least one linear array radially disposed about the sample holder. Radiation from the excitation source is directed to the sample, and the radiation induces fluorescent light in the sample. Each linear array includes a plurality of fused silica optical fibers that receive the fluorescent light and transmits a fluorescent light signal from the first end to an optical end port of the linear array. An end port assembly having a photo-detector is optically coupled to the optical end port. The photo-detector detects the fluorescent light signal and converts the fluorescent light signal into an electrical signal.

  1. Glucose sensing molecules having selected fluorescent properties

    DOE Patents [OSTI]

    Satcher, Jr., Joe H.; Lane, Stephen M.; Darrow, Christopher B.; Cary, Douglas R.; Tran, Joe Anh

    2004-01-27

    An analyte sensing fluorescent molecule that employs intramolecular electron transfer is designed to exhibit selected fluorescent properties in the presence of analytes such as saccharides. The selected fluorescent properties include excitation wavelength, emission wavelength, fluorescence lifetime, quantum yield, photostability, solubility, and temperature or pH sensitivity. The compound comprises an aryl or a substituted phenyl boronic acid that acts as a substrate recognition component, a fluorescence switch component, and a fluorophore. The fluorophore and switch component are selected such that the value of the free energy for electron transfer is less than about 3.0 kcal mol.sup.-1. Fluorescent compounds are described that are excited at wavelengths greater than 400 nm and emit at wavelengths greater than 450 nm, which is advantageous for optical transmission through skin. The fluorophore is typically selected from transition metal-ligand complexes and thiazine, oxazine, oxazone, or oxazine-one as well as anthracene compounds. The fluorescent compound can be immobilized in a glucose permeable biocompatible polymer matrix that is implantable below the skin.

  2. Rigidifying Fluorescent Linkers by Metal-Organic Framework Formation...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Rigidifying Fluorescent Linkers by Metal-Organic Framework Formation for Fluorescence Blue Shift and Quantum Yield Enhancement Previous Next List Zhangwen Wei, Zhi-Yuan Gu, Ravi K. ...

  3. Product Standards for Fluorescent Lighting (Japan) | Open Energy...

    Open Energy Info (EERE)

    Fluorescent Lighting (Japan) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Product Standards for Fluorescent Lighting (Japan) Focus Area: Appliances & Equipment...

  4. 2014-10-14 Issuance: Test Procedures Correction for Fluorescent...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    4 Issuance: Test Procedures Correction for Fluorescent Lamp Ballasts; Notice of Proposed Rulemaking 2014-10-14 Issuance: Test Procedures Correction for Fluorescent Lamp Ballasts; ...

  5. Simultaneous cryo X-ray ptychographic and fluorescence microscopy...

    Office of Scientific and Technical Information (OSTI)

    Accepted Manuscript: Simultaneous cryo X-ray ptychographic and fluorescence microscopy of green algae Prev Next Title: Simultaneous cryo X-ray ptychographic and fluorescence ...

  6. Fluorescent single walled nanotube/silica composite materials...

    Office of Scientific and Technical Information (OSTI)

    Title: Fluorescent single walled nanotubesilica composite materials Fluorescent composites of surfactant-wrapped single-walled carbon nanotubes (SWNTs) were prepared by exposing ...

  7. Fluorescent Pigments for High-Performance Cool Roofing and Facades...

    Energy Savers [EERE]

    After boiling and then combustion, a fluorescent red pigment is formed. Image: University ... After boiling and then combustion, a fluorescent red pigment is formed. Image: University ...

  8. " A Heterodyne Laser-induced Fluorescence Technique to Determine...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    A Heterodyne Laser-induced Fluorescence Technique to Determine Simultaneously the Bulk ... molecule velocity distribution using a heterodyne laser induced fluorescence technique. ...

  9. Multiplexed fluorescence detector system for capillary electrophoresis

    DOE Patents [OSTI]

    Yeung, E.S.; Taylor, J.A.

    1996-03-12

    A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis. 14 figs.

  10. Multiplexed fluorescence detector system for capillary electrophoresis

    DOE Patents [OSTI]

    Yeung, E.S.; Taylor, J.A.

    1994-06-28

    A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis. 14 figures.

  11. Development of fluorescence lifetime diagnostic. Project accomplishments

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    summary (Attachment 1), Revision 1 (Technical Report) | SciTech Connect Technical Report: Development of fluorescence lifetime diagnostic. Project accomplishments summary (Attachment 1), Revision 1 Citation Details In-Document Search Title: Development of fluorescence lifetime diagnostic. Project accomplishments summary (Attachment 1), Revision 1 × You are accessing a document from the Department of Energy's (DOE) SciTech Connect. This site is a product of DOE's Office of Scientific and

  12. Multiplexed fluorescence detector system for capillary electrophoresis

    DOE Patents [OSTI]

    Yeung, Edward S.; Taylor, John A.

    1994-06-28

    A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis.

  13. Multiplexed fluorescence detector system for capillary electrophoresis

    DOE Patents [OSTI]

    Yeung, Edward S.; Taylor, John A.

    1996-03-12

    A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis.

  14. Laser excited confocal microscope fluorescence scanner and method

    DOE Patents [OSTI]

    Mathies, Richard A.; Peck, Konan

    1992-01-01

    A fluorescent scanner for scanning the fluorescence from a fluorescence labeled separated sample on a sample carrier including a confocal microscope for illuminating a predetermined volume of the sample carrier and/or receiving and processing fluorescence emissions from said volume to provide a display of the separated sample.

  15. Laser excited confocal microscope fluorescence scanner and method

    DOE Patents [OSTI]

    Mathies, R.A.; Peck, K.

    1992-02-25

    A fluorescent scanner is designed for scanning the fluorescence from a fluorescence labeled separated sample on a sample carrier. The scanner includes a confocal microscope for illuminating a predetermined volume of the sample carrier and/or receiving and processing fluorescence emissions from the volume to provide a display of the separated sample. 8 figs.

  16. Ultratrace analysis of transuranic actinides by laser-induced fluorescence

    DOE Patents [OSTI]

    Miller, S.M.

    1983-10-31

    Ultratrace quantities of transuranic actinides are detected indirectly by their effect on the fluorescent emissions of a preselected fluorescent species. Transuranic actinides in a sample are coprecipitated with a host lattice material containing at least one preselected fluorescent species. The actinide either quenches or enhances the laser-induced fluorescence of the preselected fluorescent species. The degree of enhancement or quenching is quantitatively related to the concentration of actinide in the sample.

  17. Ultratrace analysis of transuranic actinides by laser-induced fluorescence

    DOE Patents [OSTI]

    Miller, Steven M.

    1988-01-01

    Ultratrace quantities of transuranic actinides are detected indirectly by their effect on the fluorescent emissions of a preselected fluorescent species. Transuranic actinides in a sample are coprecipitated with a host lattice material containing at least one preselected fluorescent species. The actinide either quenches or enhances the laser-induced fluorescence of the preselected fluorescent species. The degree of enhancement or quenching is quantitatively related to the concentration of actinide in the sample.

  18. Award Types

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Awards Team (505) 667-7824 Email Types of Awards The Awards Office, sponsored by the Technology Transfer Division and the Science and Technology Base Program Office, coordinates...

  19. Ultrabright fluorescent OLEDS using triplet sinks

    DOE Patents [OSTI]

    Zhang, Yifan; Forrest, Stephen R; Thompson, Mark

    2013-06-04

    A first device is provided. The first device further comprises an organic light emitting device. The organic light emitting device further comprises an anode, a cathode, and an emissive layer disposed between the anode and the cathode. The emissive layer further comprises an organic host compound, an organic emitting compound capable of fluorescent emission at room temperature, and an organic dopant compound. The triplet energy of the dopant compound is lower than the triplet energy of the host compound. The dopant compound does not strongly absorb the fluorescent emission of the emitting compound.

  20. Buildings Energy Data Book: 5.6 Lighting

    Buildings Energy Data Book [EERE]

    7 2003 Lighted Floorspace for the Stock of Commercial Buildings, by Type of Lamp (1) Type of Lamp (Billion SF) (2) Standard Fluorescent 59.7 96% Incandescent 38.5 62% Compact Fluorescent 27.6 44% High-Intensity Discharge 20.6 33% Halogen 17.7 29% Note(s): Source(s): EIA, 2003 Commercial Buildings Energy Consumption Survey: Building Characteristics Tables, June 2006, Table B44, p. 220. Lighted Floorspace Percent of Total Lighted Floorspace: 62.06 Billion SF Lighted Floorspace 1) Mall buildings

  1. DNA sequencing using fluorescence background electroblotting membrane

    DOE Patents [OSTI]

    Caldwell, K.D.; Chu, T.J.; Pitt, W.G.

    1992-05-12

    A method for the multiplex sequencing on DNA is disclosed which comprises the electroblotting or specific base terminated DNA fragments, which have been resolved by gel electrophoresis, onto the surface of a neutral non-aromatic polymeric microporous membrane exhibiting low background fluorescence which has been surface modified to contain amino groups. Polypropylene membranes are preferably and the introduction of amino groups is accomplished by subjecting the membrane to radio or microwave frequency plasma discharge in the presence of an aminating agent, preferably ammonia. The membrane, containing physically adsorbed DNA fragments on its surface after the electroblotting, is then treated with crosslinking means such as UV radiation or a glutaraldehyde spray to chemically bind the DNA fragments to the membrane through amino groups contained on the surface. The DNA fragments chemically bound to the membrane are subjected to hybridization probing with a tagged probe specific to the sequence of the DNA fragments. The tagging may be by either fluorophores or radioisotopes. The tagged probes hybridized to the target DNA fragments are detected and read by laser induced fluorescence detection or autoradiograms. The use of aminated low fluorescent background membranes allows the use of fluorescent detection and reading even when the available amount of DNA to be sequenced is small. The DNA bound to the membranes may be reprobed numerous times. No Drawings

  2. DNA sequencing using fluorescence background electroblotting membrane

    DOE Patents [OSTI]

    Caldwell, Karin D.; Chu, Tun-Jen; Pitt, William G.

    1992-01-01

    A method for the multiplex sequencing on DNA is disclosed which comprises the electroblotting or specific base terminated DNA fragments, which have been resolved by gel electrophoresis, onto the surface of a neutral non-aromatic polymeric microporous membrane exhibiting low background fluorescence which has been surface modified to contain amino groups. Polypropylene membranes are preferably and the introduction of amino groups is accomplished by subjecting the membrane to radio or microwave frequency plasma discharge in the presence of an aminating agent, preferably ammonia. The membrane, containing physically adsorbed DNA fragments on its surface after the electroblotting, is then treated with crosslinking means such as UV radiation or a glutaraldehyde spray to chemically bind the DNA fragments to the membrane through said smino groups contained on the surface thereof. The DNA fragments chemically bound to the membrane are subjected to hybridization probing with a tagged probe specific to the sequence of the DNA fragments. The tagging may be by either fluorophores or radioisotopes. The tagged probes hybridized to said target DNA fragments are detected and read by laser induced fluorescence detection or autoradiograms. The use of aminated low fluorescent background membranes allows the use of fluorescent detection and reading even when the available amount of DNA to be sequenced is small. The DNA bound to the membrances may be reprobed numerous times.

  3. Size-dependent fluorescence of bioaerosols: Mathematical model using fluorescing and absorbing molecules in bacteria

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Hill, Steven C.; Williamson, Chatt C.; Doughty, David C.; Pan, Yong-Le; Santarpia, Joshua L.; Hill, Hanna H.

    2015-02-02

    This paper uses a mathematical model of fluorescent biological particles composed of bacteria and/or proteins (mostly as in Hill et al., 2013 [23]) to investigate the size-dependence of the total fluorescence emitted in all directions. The model applies to particles which have negligible reabsorption of fluorescence within the particle. The specific particles modeled here are composed of ovalbumin and of a generic Bacillus. The particles need not be spherical, and in some cases need not be homogeneous. However, the results calculated in this paper are for spherical homogeneous particles. Light absorbing and fluorescing molecules included in the model are aminomore » acids, nucleic acids, and several coenzymes. Here the excitation wavelength is 266 nm. The emission range, 300 to 370 nm, encompasses the fluorescence of tryptophan. The fluorescence cross section (CF) is calculated and compared with one set of published measured values. We investigate power law (Ady) approximations to CF, where d is diameter, and A and y are parameters adjusted to fit the data, and examine how y varies with d and composition, including the fraction as water. The particle's fluorescence efficiency (QF=CF/geometric-cross-section) can be written for homogeneous particles as QabsRF, where Qabs is the absorption efficiency, and RF, the fraction of the absorbed light emitted as fluorescence, is independent of size and shape. When QF is plotted vs. mid or mi(mr-1)d, where m=mr+imi is the complex refractive index, the plots for different fractions of water in the particle tend to overlap.« less

  4. Size-dependent fluorescence of bioaerosols: Mathematical model using fluorescing and absorbing molecules in bacteria

    SciTech Connect (OSTI)

    Hill, Steven C.; Williamson, Chatt C.; Doughty, David C.; Pan, Yong-Le; Santarpia, Joshua L.; Hill, Hanna H.

    2015-02-02

    This paper uses a mathematical model of fluorescent biological particles composed of bacteria and/or proteins (mostly as in Hill et al., 2013 [23]) to investigate the size-dependence of the total fluorescence emitted in all directions. The model applies to particles which have negligible reabsorption of fluorescence within the particle. The specific particles modeled here are composed of ovalbumin and of a generic Bacillus. The particles need not be spherical, and in some cases need not be homogeneous. However, the results calculated in this paper are for spherical homogeneous particles. Light absorbing and fluorescing molecules included in the model are amino acids, nucleic acids, and several coenzymes. Here the excitation wavelength is 266 nm. The emission range, 300 to 370 nm, encompasses the fluorescence of tryptophan. The fluorescence cross section (CF) is calculated and compared with one set of published measured values. We investigate power law (Ady) approximations to CF, where d is diameter, and A and y are parameters adjusted to fit the data, and examine how y varies with d and composition, including the fraction as water. The particle's fluorescence efficiency (QF=CF/geometric-cross-section) can be written for homogeneous particles as QabsRF, where Qabs is the absorption efficiency, and RF, the fraction of the absorbed light emitted as fluorescence, is independent of size and shape. When QF is plotted vs. mid or mi(mr-1)d, where m=mr+imi is the complex refractive index, the plots for different fractions of water in the particle tend to overlap.

  5. Apparatus for eliminating background interference in fluorescence measurements

    DOE Patents [OSTI]

    Martin, J.C.; Jett, J.H.

    1986-03-04

    The disclosure is directed to an apparatus for eliminating background interference during fluorescence measurements in a multiple laser flow cytometer. A biological particle stained with fluorescent dyes is excited by a laser. A fluorescence detector detects the fluorescence. The particle scatters light and a gate signal is generated and delayed until the biological particle reaches the next laser. The delayed signal turns on this next laser, which excites a different stained component of the same biological particle. 8 figs.

  6. Apparatus for eliminating background interference in fluorescence measurements

    DOE Patents [OSTI]

    Martin, John C.; Jett, James H.

    1986-01-01

    The disclosure is directed to an apparatus for eliminating background interference during fluorescence measurements in a multiple laser flow cytometer. A biological particle stained with fluorescent dyes is excited by a laser. A fluorescence detector detects the fluorescence. The particle scatters light and a gate signal is generated and delayed until the biological particle reaches the next laser. The delayed signal turns on this next laser, which excites a different stained component of the same biological particle.

  7. Apparatus for eliminating background interference in fluorescence measurements

    DOE Patents [OSTI]

    Martin, J.C.; Jett, J.H.

    1984-01-06

    The disclosure is directed to an apparatus for eliminating background interference during fluorescence measurements in a multiple laser flow cytometer. A biological particle stained with fluorescent dyes is excited by a laser. A fluorescence detector detects the fluorescence. The particle scatters light and a gate signal is generated and delayed until the biological particle reaches the next laser. The delayed signal turns on this next laser which excites a different stained component of the same biological particle.

  8. A Bright Idea: New Efficiency Standards for Incandescent and...

    Office of Environmental Management (EM)

    July 21, 2009 - 5:18pm Addthis John Lippert Pretty soon, lighting is going to get a lot ... trying to adopt more energy-efficient lighting; it has also spurred media articles ...

  9. How Energy-Efficient Light Bulbs Compare with Traditional Incandescent...

    Energy Savers [EERE]

    Light Bulbs Compare with Traditional ... The table below compares a 60 watt (W) traditional ... *Based on 2 hrsday of usage, an electricity rate of 11 ...

  10. DOE Requires Manufacturer and Labeler to Cease Sale of Incandescent...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Non-Compliance Determination to Westinghouse Lighting Corporation and Fuzhou Sunlight Lighting Electrical Appliance Company requiring that they halt the sale of 8 basic...

  11. Type: Renewal

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1 INCITE Awards Type: Renewal Title: -Ab Initio Dynamical Simulations for the Prediction of Bulk Properties‖ Principal Investigator: Theresa Windus, Iowa State University Co-Investigators: Brett Bode, Iowa State University Graham Fletcher, Argonne National Laboratory Mark Gordon, Iowa State University Monica Lamm, Iowa State University Michael Schmidt, Iowa State University Scientific Discipline: Chemistry: Physical INCITE Allocation: 10,000,000 processor hours Site: Argonne National

  12. Facility Type!

    Office of Legacy Management (LM)

    ITY: --&L~ ----------- srct-r~ -----------~------~------- if yee, date contacted ------------- cl Facility Type! i I 0 Theoretical Studies Cl Sample 84 Analysis ] Production 1 Diepasal/Storage 'YPE OF CONTRACT .--------------- 1 Prime J Subcontract&- 1 Purchase Order rl i '1 ! Other information (i.e., ---------~---~--~-------- :ontrait/Pirchaee Order # , I C -qXlJ- --~-------~~-------~~~~~~ I I ~~~---~~~~~~~T~~~ FONTRACTING PERIODi IWNERSHIP: ,I 1 AECIMED AECMED GOVT GOUT &NTtiAC+OR

  13. Invisible-fluorescent identification tags for materials

    SciTech Connect (OSTI)

    Lewis, Linda A.; Allgood, Glenn O.; Smithwick, III, Robert W.

    2013-03-26

    A taggant composition including a taggant material that is invisible in light of the visible spectrum and fluoresces under a non-visible excitation energy, a binder, and a solvent in which the taggant material and the binder are dissolved. The taggant composition can be printed or otherwise applied to a material such as fabric to provide a detectable and identifiable indicium. A method and apparatus for detecting and decoding the taggant indicium are also provided.

  14. Fluorescent lighting with aluminum nitride phosphors

    DOE Patents [OSTI]

    Cherepy, Nerine J.; Payne, Stephen A.; Seeley, Zachary M.; Srivastava, Alok M.

    2016-05-10

    A fluorescent lamp includes a glass envelope; at least two electrodes connected to the glass envelope; mercury vapor and an inert gas within the glass envelope; and a phosphor within the glass envelope, wherein the phosphor blend includes aluminum nitride. The phosphor may be a wurtzite (hexagonal) crystalline structure Al.sub.(1-x)M.sub.xN phosphor, where M may be drawn from beryllium, magnesium, calcium, strontium, barium, zinc, scandium, yttrium, lanthanum, cerium, praseodymium, europium, gadolinium, terbium, ytterbium, bismuth, manganese, silicon, germanium, tin, boron, or gallium is synthesized to include dopants to control its luminescence under ultraviolet excitation. The disclosed Al.sub.(1-x)M.sub.xN:Mn phosphor provides bright orange-red emission, comparable in efficiency and spectrum to that of the standard orange-red phosphor used in fluorescent lighting, Y.sub.2O.sub.3:Eu. Furthermore, it offers excellent lumen maintenance in a fluorescent lamp, and does not utilize "critical rare earths," minimizing sensitivity to fluctuating market prices for the rare earth elements.

  15. Type here

    Office of Environmental Management (EM)

    Injury at the Savannah River National Laboratory | Department of Energy January 10, 2006, Flash Fire and Injury at the Savannah River National Laboratory Type B Accident Investigation of the January 10, 2006, Flash Fire and Injury at the Savannah River National Laboratory February 1, 2006 On January 10, 2006, at approximately 7:47 a.m., a first-line manager (FLM) at the Savannah River National Laboratory (SRNL) received first- and second-degree burns to his head, face, neck, and left hand

  16. Preliminary evaluation of a fluorescence and radioisotope nuclear smuggling deterrence tag - final report (IL500E)

    SciTech Connect (OSTI)

    Hartenstein, S.D.; Aryaeinejad, R.; Delmastro, J.R.

    1997-04-01

    This report summarizes the efforts completed in identifying candidate fluorescence compounds and radioisotopes for a developing tagging system. The tagging system is being developed as a deterrent to nuclear smuggling, by providing a means of: (1) tracing materials and pilferers to the facility of origin for any recovered special nuclear materials, (2) inventory control of long-term stored items containing special nuclear materials, and (3) tracking materials transferred between facilities. The system uses three types of materials to cover a range of applications intended to prevent the pilfering of special nuclear materials. One material, fluorescent compounds which are invisible without ultraviolet or near-infrared detection systems, is marked on controlled items with a tracking pattern that corresponds to a specified item in a specified location in the data control system. The tagging system uses an invisible, fluorescent dusting powder to mark equipment and personnel who inappropriately handle the tagged material. The tagging system also uses unique combinations of radionuclides to identify the facility of origin for any special nuclear material. This report also summarizes the efforts completed in identifying hardware that will be used for the tagging system. This hardware includes the devices for applying the tagging materials, the commercially available fluorescence detection systems, and gamma ray detection systems assembled from existing, commercially available technologies.

  17. Superior optical nonlinearity of an exceptional fluorescent stilbene dye

    SciTech Connect (OSTI)

    He, Tingchao; Sreejith, Sivaramapanicker; Zhao, Yanli; Gao, Yang; Grimsdale, Andrew C.; Lin, Xiaodong E-mail: hdsun@ntu.edu.sg; Sun, Handong E-mail: hdsun@ntu.edu.sg

    2015-03-16

    Strong multiphoton absorption and harmonic generation in organic fluorescent chromophores are, respectively, significant in many fields of research. However, most of fluorescent chromophores fall short of the full potential due to the absence of the combination of such different nonlinear upconversion behaviors. Here, we demonstrate that an exceptional fluorescent stilbene dye could exhibit efficient two- and three-photon absorption under the excitation of femtosecond pulses in solution phase. Benefiting from its biocompatibility and strong excited state absorption behavior, in vitro two-photon bioimaging and superior optical limiting have been exploited, respectively. Simultaneously, the chromophore could generate efficient three-photon excited fluorescence and third-harmonic generation (THG) when dispersed into PMMA film, circumventing the limitations of classical fluorescent chromophores. Such chromophore may find application in the production of coherent light sources of higher photon energy. Moreover, the combination of three-photon excited fluorescence and THG can be used in tandem to provide complementary information in biomedical studies.

  18. Lighting the Way with Compact Fluorescent Lighting | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Lighting the Way with Compact Fluorescent Lighting Lighting the Way with Compact Fluorescent Lighting April 28, 2009 - 5:00am Addthis John Lippert There is a major push today to get homeowners to adopt compact fluorescent lamp (CFL) light bulbs. They have been on the market for nearly three decades, and many homeowners still do not use them widely. But the tide is definitely turning. Their availability and the percentage of homeowners familiar with the technology and purchasing them for their

  19. Purchasing Energy-Efficient Ceiling-Mounted Fluorescent Luminaires |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Ceiling-Mounted Fluorescent Luminaires Purchasing Energy-Efficient Ceiling-Mounted Fluorescent Luminaires The Federal Energy Management Program (FEMP) provides acquisition guidance for ceiling-mounted fluorescent luminaires, a product category covered by FEMP efficiency requirements. Federal laws and requirements mandate that agencies purchase ENERGY STAR-qualified or FEMP-designated products in all product categories covered by these programs and in any acquisition

  20. Purchasing Energy-Efficient Fluorescent Ballasts | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fluorescent Ballasts Purchasing Energy-Efficient Fluorescent Ballasts The Federal Energy Management Program (FEMP) provides acquisition guidance for fluorescent ballasts, a product category covered by FEMP efficiency requirements. Federal laws and requirements mandate that agencies purchase ENERGY STAR-qualified or FEMP-designated products in all product categories covered by these programs and in any acquisition actions that are not specifically exempted by law. FEMP's acquisition guidance and

  1. Purchasing Energy-Efficient General Service Fluorescent Lamps | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy Purchasing Energy-Efficient General Service Fluorescent Lamps Purchasing Energy-Efficient General Service Fluorescent Lamps The Federal Energy Management Program (FEMP) provides acquisition guidance for general service fluorescent lamps (GSFLs), a product category covered by FEMP efficiency requirements. Federal laws and requirements mandate that agencies purchase ENERGY STAR qualified or FEMP designated products in all product categories covered by these programs and in any

  2. Purchasing Energy-Efficient Suspended Fluorescent Luminaires | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy Products & Technologies » Energy-Efficient Products » Purchasing Energy-Efficient Suspended Fluorescent Luminaires Purchasing Energy-Efficient Suspended Fluorescent Luminaires The Federal Energy Management Program (FEMP) provides acquisition guidance for suspended fluorescent luminaires, a product category covered by FEMP efficiency requirements. Federal laws and requirements mandate that agencies purchase ENERGY STAR-qualified or FEMP-designated products in all product

  3. Solid state laser media driven by remote nuclear powered fluorescence

    DOE Patents [OSTI]

    Prelas, Mark A.

    1992-01-01

    An apparatus is provided for driving a solid state laser by a nuclear powered fluorescence source which is located remote from the fluorescence source. A nuclear reaction produced in a reaction chamber generates fluorescence or photons. The photons are collected from the chamber into a waveguide, such as a fiber optic waveguide. The waveguide transports the photons to the remote laser for exciting the laser.

  4. Yellow fluorescent protein phiYFPv (Phialidium): structure and structure-based mutagenesis

    SciTech Connect (OSTI)

    Pletneva, Nadya V.; Pletnev, Vladimir Z. Souslova, Ekaterina; Chudakov, Dmitry M.; Lukyanov, Sergey; Martynov, Vladimir I.; Arhipova, Svetlena; Artemyev, Igor; Wlodawer, Alexander; Dauter, Zbigniew; Pletnev, Sergei

    2013-06-01

    The yellow fluorescent protein phiYFPv with improved folding has been developed from the spectrally identical wild-type phiYFP found in the marine jellyfish Phialidium. The yellow fluorescent protein phiYFPv (λ{sub em}{sup max} ≃ 537 nm) with improved folding has been developed from the spectrally identical wild-type phiYFP found in the marine jellyfish Phialidium. The latter fluorescent protein is one of only two known cases of naturally occurring proteins that exhibit emission spectra in the yellow–orange range (535–555 nm). Here, the crystal structure of phiYFPv has been determined at 2.05 Å resolution. The ‘yellow’ chromophore formed from the sequence triad Thr65-Tyr66-Gly67 adopts the bicyclic structure typical of fluorophores emitting in the green spectral range. It was demonstrated that perfect antiparallel π-stacking of chromophore Tyr66 and the proximal Tyr203, as well as Val205, facing the chromophore phenolic ring are chiefly responsible for the observed yellow emission of phiYFPv at 537 nm. Structure-based site-directed mutagenesis has been used to identify the key functional residues in the chromophore environment. The obtained results have been utilized to improve the properties of phiYFPv and its homologous monomeric biomarker tagYFP.

  5. Simultaneous cryo X-ray ptychographic and fluorescence microscopy...

    Office of Scientific and Technical Information (OSTI)

    ptychographic and fluorescence microscopy of green algae You are accessing a document from the Department of Energy's (DOE) Public Access Gateway for Energy & Science (PAGES). ...

  6. Stable and responsive fluorescent carbon nanotube silica gels...

    Office of Scientific and Technical Information (OSTI)

    silica nanocomposite gels doped with fluorescent single walled carbon nanotubes (SWNT). ... of highly luminescent SWNTsilica composite materials that are potentially useful ...

  7. Simultaneous cryo X-ray ptychographic and fluorescence microscopy...

    Office of Scientific and Technical Information (OSTI)

    and fluorescence microscopy of green algae Citation Details In-Document Search ... Visit OSTI to utilize additional information resources in energy science and technology. A ...

  8. Better Fluorescent Lighting Through Physics | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    National Labs are working with industry to make fluorescent lighting more environmentally friendly by reducing the need for rare earth elements. | iStock photo. National Labs are ...

  9. Mapping protein collapse with single molecule fluorescence and...

    Office of Scientific and Technical Information (OSTI)

    spectroscopy Citation Details In-Document Search Title: Mapping protein collapse with single molecule fluorescence and kinetic synchrotron radiation circular dichroism spectroscopy ...

  10. Time-resolved fluorescence decay measurements for flowing particles

    DOE Patents [OSTI]

    Deka, Chiranjit; Steinkamp, John A.

    1999-01-01

    Time-resolved fluorescence decay measurements for flowing particles. An apparatus and method for the measurement and analysis of fluorescence for individual cells and particles in flow are described, wherein the rapid measurement capabilities of flow cytometry and the robust measurement and analysis procedures of time-domain fluorescence lifetime spectroscopy are combined. A pulse-modulated cw laser is employed for excitation of the particles. The characteristics and the repetition rate of the excitation pulses can be readily adjusted to accommodate for fluorescence decays having a wide range of lifetimes.

  11. Time-resolved fluorescence decay measurements for flowing particles

    DOE Patents [OSTI]

    Deka, C.; Steinkamp, J.A.

    1999-06-01

    Time-resolved fluorescence decay measurements are disclosed for flowing particles. An apparatus and method for the measurement and analysis of fluorescence for individual cells and particles in flow are described, wherein the rapid measurement capabilities of flow cytometry and the robust measurement and analysis procedures of time-domain fluorescence lifetime spectroscopy are combined. A pulse-modulated CW laser is employed for excitation of the particles. The characteristics and the repetition rate of the excitation pulses can be readily adjusted to accommodate for fluorescence decays having a wide range of lifetimes. 12 figs.

  12. CMI-funded research creates better fluorescent lighting | The...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    CMI-funded research creates better fluorescent lighting General Electric (GE), Lawrence Livermore National Laboratory (LLNL) and Oak Ridge National Laboratory (ORNL) have created...

  13. Site-Specific Synthesis and In Situ Immobilization of Fluorescent...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Site-Specific Synthesis and In Situ Immobilization of Fluorescent Silver Nanoclusters on DNA Nanoscaffolds by Use of the Tollens Reaction Authors: Pal, S., Varghese, R., Deng, Z.,...

  14. Fluorescent tracking of nickel ions in human cultured cells ...

    Office of Scientific and Technical Information (OSTI)

    Fluorescent tracking of nickel ions in human cultured cells Citation Details In-Document ... B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International ...

  15. Max Tech and Beyond: Fluorescent Lamps

    SciTech Connect (OSTI)

    Scholand, Michael

    2012-04-01

    Fluorescent lamps are the most widely used artificial light source today, responsible for approximately 70% of the lumens delivered to our living spaces globally. The technology was originally commercialized in the 1930's, and manufacturers have been steadily improving the efficacy of these lamps over the years through modifications to the phosphors, cathodes, fill-gas, operating frequency, tube diameter and other design attributes. The most efficient commercially available fluorescent lamp is the 25 Watt T5 lamp. This lamp operates at 114-116 lumens per watt while also providing good color rendering and more than 20,000 hours of operating life. Industry experts interviewed indicated that while this lamp is the most efficient in the market today, there is still a further 10 to 14% of potential improvements that may be introduced to the market over the next 2 to 5 years. These improvements include further developments in phosphors, fill-gas, cathode coatings and ultraviolet (UV) reflective glass coatings. The commercialization of these technology improvements will combine to bring about efficacy improvements that will push the technology up to a maximum 125 to 130 lumens per watt. One critical issue raised by researchers that may present a barrier to the realization of these improvements is the fact that technology investment in fluorescent lamps is being reduced in order to prioritize research into light emitting diodes (LEDs) and ceramic metal halide high intensity discharge (HID) lamps. Thus, it is uncertain whether these potential efficacy improvements will be developed, patented and commercialized. The emphasis for premium efficacy will continue to focus on T5 lamps, which are expected to continue to be marketed along with the T8 lamp. Industry experts highlighted the fact that an advantage of the T5 lamp is the fact that it is 40% smaller and yet provides an equivalent lumen output to that of a T8 or T12 lamp. Due to its smaller form factor, the T5 lamp

  16. Nuclear Resonance Fluorescence for Materials Assay

    SciTech Connect (OSTI)

    Quiter, Brian J.; Ludewigt, Bernhard; Mozin, Vladimir; Prussin, Stanley

    2009-06-29

    This paper discusses the use of nuclear resonance fluorescence (NRF) techniques for the isotopic and quantitative assaying of radioactive material. Potential applications include age-dating of an unknown radioactive source, pre- and post-detonation nuclear forensics, and safeguards for nuclear fuel cycles Examples of age-dating a strong radioactive source and assaying a spent fuel pin are discussed. The modeling work has ben performed with the Monte Carlo radiation transport computer code MCNPX, and the capability to simulate NRF has bee added to the code. Discussed are the limitations in MCNPX?s photon transport physics for accurately describing photon scattering processes that are important contributions to the background and impact the applicability of the NRF assay technique.

  17. Nuclear Resonance Fluorescence for Materials Assay

    SciTech Connect (OSTI)

    Quiter, Brian; Ludewigt, Bernhard; Mozin, Vladimir; Prussin, Stanley

    2009-06-05

    This paper discusses the use of nuclear resonance fluorescence (NRF) techniques for the isotopic and quantitative assaying of radioactive material. Potential applications include age-dating of an unknown radioactive source, pre- and post-detonation nuclear forensics, and safeguards for nuclear fuel cycles Examples of age-dating a strong radioactive source and assaying a spent fuel pin are discussed. The modeling work has ben performed with the Monte Carlo radiation transport computer code MCNPX, and the capability to simulate NRF has bee added to the code. Discussed are the limitations in MCNPX's photon transport physics for accurately describing photon scattering processes that are important contributions to the background and impact the applicability of the NRF assay technique.

  18. Radioiodine detector based on laser induced fluorescence

    DOE Patents [OSTI]

    McDonald, Jimmie R.; Baronavski, Andrew P.

    1980-01-01

    The invention involves the measurement of the concentration of the radioisotope .sup.129 I.sub.2 in the presence of a gas. The invention uses a laser to excite a sample of the .sup.129 I.sub.2 in a sample gas chamber and a reference sample of a known concentration of .sup.129 I.sub.2 in a reference gas chamber. The .sup.129 I.sub.2 in the sample and reference gas chamber each gives off fluorescence emissions which are received by photomultipliers which provide signals to a detector. The detector uses a ratioing technique to determine the concentration of .sup.129 I.sub.2 in the sample gas chamber.

  19. Untitled

    U.S. Energy Information Administration (EIA) Indexed Site

    descriptions of the amount of electricity used for lighting and variations in households' consumption of electricity for lighting. Types of Lights Dominance of Incandescent Lights...

  20. Fluorescent lamp unit with magnetic field generating means

    DOE Patents [OSTI]

    Grossman, Mark W.; George, William A.

    1989-01-01

    A fluorescent lamp unit having a magnetic field generating means for improving the performance of the fluorescent lamp is disclosed. In a preferred embodiment the fluorescent lamp comprises four longitudinally extending leg portions disposed in substantially quadrangular columnar array and joined by three generally U-shaped portions disposed in different planes. In another embodiment of the invention the magnetic field generating means comprises a plurality of permanent magnets secured together to form a single columnar structure disposed within a centrally located region defined by the shape of lamp envelope.

  1. Fluorescent lamp unit with magnetic field generating means

    DOE Patents [OSTI]

    Grossman, M.W.; George, W.A.

    1989-08-08

    A fluorescent lamp unit having a magnetic field generating means for improving the performance of the fluorescent lamp is disclosed. In a preferred embodiment the fluorescent lamp comprises four longitudinally extending leg portions disposed in substantially quadrangular columnar array and joined by three generally U-shaped portions disposed in different planes. In another embodiment of the invention the magnetic field generating means comprises a plurality of permanent magnets secured together to form a single columnar structure disposed within a centrally located region defined by the shape of lamp envelope. 4 figs.

  2. Ultrahigh resolution multicolor colocalization of single fluorescent probes

    DOE Patents [OSTI]

    Weiss, Shimon; Michalet, Xavier; Lacoste, Thilo D.

    2005-01-18

    A novel optical ruler based on ultrahigh-resolution colocalization of single fluorescent probes is described. Two unique families of fluorophores are used, namely energy-transfer fluorescent beads and semiconductor nanocrystal (NC) quantum dots, that can be excited by a single laser wavelength but emit at different wavelengths. A novel multicolor sample-scanning confocal microscope was constructed which allows one to image each fluorescent light emitter, free of chromatic aberrations, by scanning the sample with nanometer scale steps using a piezo-scanner. The resulting spots are accurately localized by fitting them to the known shape of the excitation point-spread-function of the microscope.

  3. Integrated ultrasonic particle positioning and low excitation light fluorescence imaging

    SciTech Connect (OSTI)

    Bernassau, A. L.; Al-Rawhani, M.; Beeley, J.; Cumming, D. R. S. [School of Engineering, University of Glasgow, Glasgow, G12 8LT (United Kingdom)] [School of Engineering, University of Glasgow, Glasgow, G12 8LT (United Kingdom)

    2013-12-09

    A compact hybrid system has been developed to position and detect fluorescent micro-particles by combining a Single Photon Avalanche Diode (SPAD) imager with an acoustic manipulator. The detector comprises a SPAD array, light-emitting diode (LED), lenses, and optical filters. The acoustic device is formed of multiple transducers surrounding an octagonal cavity. By stimulating pairs of transducers simultaneously, an acoustic landscape is created causing fluorescent micro-particles to agglomerate into lines. The fluorescent pattern is excited by a low power LED and detected by the SPAD imager. Our technique combines particle manipulation and visualization in a compact, low power, portable setup.

  4. System and method for measuring fluorescence of a sample

    DOE Patents [OSTI]

    Riot, Vincent J

    2015-03-24

    The present disclosure provides a system and a method for measuring fluorescence of a sample. The sample may be a polymerase-chain-reaction (PCR) array, a loop-mediated-isothermal amplification array, etc. LEDs are used to excite the sample, and a photodiode is used to collect the sample's fluorescence. An electronic offset signal is used to reduce the effects of background fluorescence and the noises from the measurement system. An integrator integrates the difference between the output of the photodiode and the electronic offset signal over a given period of time. The resulting integral is then converted into digital domain for further processing and storage.

  5. Optical Control of Fluorescence through plasmonic eigenmode extinction

    SciTech Connect (OSTI)

    Xu, Xiaoying; Lin, Shih-Che; Li, Quanshui; Zhang, Zhili; Ivanov, Ilia N.; Li, Yuan; Wang, Wenbin; Gu, Baohua; Zhang, Zhenyu; Hsueh, C. H.; Snijders, Paul C.; Seal, Katyayani

    2015-04-30

    We introduce the concept of optical control of the fluorescence yield of CdSe quantum dots through plasmon-induced structural changes in random semicontinuous nanostructured gold films. We demonstrate that the wavelength- and polarization dependent coupling between quantum dots and the semicontinuous films, and thus the fluorescent emission spectrum, can be controlled and significantly increased through the optical extinction of a selective band of eigenmodes in the films. This optical method of effecting controlled changes in the metal nanostructure allows for versatile functionality in a single sample and opens a pathway to in situ control over the fluorescence spectrum.

  6. Life-Cycle Assessment of Energy and Environmental Impacts of...

    Energy Savers [EERE]

    Life-Cycle Assessment of Energy and Environmental Impacts of LED Lighting Products Part I: Review of the Life-Cycle Energy Consumption of Incandescent, Compact Fluorescent, and LED ...

  7. School Energy Survey Student Guide

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of 40 new power plants. INCANDESCENT BULB HALOGEN COMPACT FLUORESCENT (CFL) LIGHT EMITTING DIODE (LED) Brightness 850 lumens 850 lumens 850 lumens 850 lumens Life of Bulb 1,000...

  8. School Energy Survey Teacher Guide

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Key Student Guide Page 20 INCANDESCENT BULB HALOGEN COMPACT FLUORESCENT (CFL) LIGHT EMITTING DIODE (LED) Number of bulbs to get 25,000 hours 25 8.3 2.5 1 Cost of bulbs for 25,000...

  9. Energy Savings Forecast of Solid-State Lighting in General Illumination Applications

    Broader source: Energy.gov [DOE]

    Report forecasting the U.S. energy savings of LED white-light sources compared to conventional white-light sources (i.e., incandescent, halogen, fluorescent, and high-intensity discharge) over the...

  10. Crystallographic study of red fluorescent protein eqFP578 and its far-red variant Katushka reveals opposite pH-induced isomerization of chromophore

    SciTech Connect (OSTI)

    Pletneva, Nadya V.; Pletnev, Vladimir Z.; Shemiakina, Irina I.; Chudakov, Dmitriy M.; Artemyev, Igor; Wlodawer, Alexander; Dauter, Zbigniew; Pletnev, Sergei

    2012-08-10

    The wild type red fluorescent protein eqFP578 (from sea anemone Entacmaea quadricolor, {lambda}{sub ex} = 552 nm, {lambda}{sub em} = 578 nm) and its bright far-red fluorescent variant Katushka ({lambda}{sub ex} = 588 nm, {lambda}{sub em} = 635 nm) are characterized by the pronounced pH dependence of their fluorescence. The crystal structures of eqFP578f (eqFP578 with two point mutations improving the protein folding) and Katushka have been determined at the resolution ranging from 1.15 to 1.85 {angstrom} at two pH values, corresponding to low and high level of fluorescence. The observed extinguishing of fluorescence upon reducing pH in eqFP578f and Katushka has been shown to be accompanied by the opposite trans-cis and cis-trans chromophore isomerization, respectively. Asn143, Ser158, His197 and Ser143, Leu174, and Arg197 have been shown to stabilize the respective trans and cis fluorescent states of the chromophores in eqFP578f and Katushka at higher pH. The cis state has been suggested as being primarily responsible for the observed far-red shift of the emission maximum of Katushka relative to that of eqFP578f.

  11. Calibration of fluorescence resonance energy transfer in microscopy

    DOE Patents [OSTI]

    Youvan, Dougalas C.; Silva, Christopher M.; Bylina, Edward J.; Coleman, William J.; Dilworth, Michael R.; Yang, Mary M.

    2003-12-09

    Imaging hardware, software, calibrants, and methods are provided to visualize and quantitate the amount of Fluorescence Resonance Energy Transfer (FRET) occurring between donor and acceptor molecules in epifluorescence microscopy. The MicroFRET system compensates for overlap among donor, acceptor, and FRET spectra using well characterized fluorescent beads as standards in conjunction with radiometrically calibrated image processing techniques. The MicroFRET system also provides precisely machined epifluorescence cubes to maintain proper image registration as the sample is illuminated at the donor and acceptor excitation wavelengths. Algorithms are described that pseudocolor the image to display pixels exhibiting radiometrically-corrected fluorescence emission from the donor (blue), the acceptor (green) and FRET (red). The method is demonstrated on samples exhibiting FRET between genetically engineered derivatives of the Green Fluorescent Protein (GFP) bound to the surface of Ni chelating beads by histidine-tags.

  12. Calibration of fluorescence resonance energy transfer in microscopy

    DOE Patents [OSTI]

    Youvan, Douglas C.; Silva, Christopher M.; Bylina, Edward J.; Coleman, William J.; Dilworth, Michael R.; Yang, Mary M.

    2002-09-24

    Imaging hardware, software, calibrants, and methods are provided to visualize and quantitate the amount of Fluorescence Resonance Energy Transfer (FRET) occurring between donor and acceptor molecules in epifluorescence microscopy. The MicroFRET system compensates for overlap among donor, acceptor, and FRET spectra using well characterized fluorescent beads as standards in conjunction with radiometrically calibrated image processing techniques. The MicroFRET system also provides precisely machined epifluorescence cubes to maintain proper image registration as the sample is illuminated at the donor and acceptor excitation wavelengths. Algorithms are described that pseudocolor the image to display pixels exhibiting radiometrically-corrected fluorescence emission from the donor (blue), the acceptor (green) and FRET (red). The method is demonstrated on samples exhibiting FRET between genetically engineered derivatives of the Green Fluorescent Protein (GFP) bound to the surface of Ni chelating beads by histidine-tags.

  13. Protein subcellular localization assays using split fluorescent proteins

    DOE Patents [OSTI]

    Waldo, Geoffrey S.; Cabantous, Stephanie

    2009-09-08

    The invention provides protein subcellular localization assays using split fluorescent protein systems. The assays are conducted in living cells, do not require fixation and washing steps inherent in existing immunostaining and related techniques, and permit rapid, non-invasive, direct visualization of protein localization in living cells. The split fluorescent protein systems used in the practice of the invention generally comprise two or more self-complementing fragments of a fluorescent protein, such as GFP, wherein one or more of the fragments correspond to one or more beta-strand microdomains and are used to "tag" proteins of interest, and a complementary "assay" fragment of the fluorescent protein. Either or both of the fragments may be functionalized with a subcellular targeting sequence enabling it to be expressed in or directed to a particular subcellular compartment (i.e., the nucleus).

  14. Method and apparatus for detection of fluorescently labeled materials

    DOE Patents [OSTI]

    Stern, David; Fiekowsky, Peter

    2004-05-25

    Fluorescently marked targets bind to a substrate 230 synthesized with polymer sequences at known locations. The targets are detected by exposing selected regions of the substrate 230 to light from a light source 100 and detecting the photons from the light fluoresced therefrom, and repeating the steps of exposure and detection until the substrate 230 is completely examined. The resulting data can be used to determine binding affinity of the targets to specific polymer sequences.

  15. Assessment of Nuclear Resonance Fluorescence for Spent Nuclear Fuel Assay

    SciTech Connect (OSTI)

    Quiter, Brian; Ludewigt, Bernhard; Ambers, Scott

    2011-06-30

    In nuclear resonance fluorescence (NRF) measurements, resonances are excited by an external photon beam leading to the emission of gamma rays with specific energies that are characteristic of the emitting isotope. NRF promises the unique capability of directly quantifying a specific isotope without the need for unfolding the combined responses of several fissile isotopes as is required in other measurement techniques. We have analyzed the potential of NRF as a non-destructive analysis technique for quantitative measurements of Pu isotopes in spent nuclear fuel (SNF). Given the low concentrations of 239Pu in SNF and its small integrated NRF cross sections, the main challenge in achieving precise and accurate measurements lies in accruing sufficient counting statistics in a reasonable measurement time. Using analytical modeling, and simulations with the radiation transport code MCNPX that has been experimentally tested recently, the backscatter and transmission methods were quantitatively studied for differing photon sources and radiation detector types. Resonant photon count rates and measurement times were estimated for a range of photon source and detection parameters, which were used to determine photon source and gamma-ray detector requirements. The results indicate that systems based on a bremsstrahlung source and present detector technology are not practical for high-precision measurements of 239Pu in SNF. Measurements that achieve the desired uncertainties within hour-long measurements will either require stronger resonances, which may be expressed by other Pu isotopes, or require quasi-monoenergetic photon sources with intensities that are approximately two orders of magnitude higher than those currently being designed or proposed.This work is part of a larger effort sponsored by the Next Generation Safeguards Initiative to develop an integrated instrument, comprised of individual NDA techniques with complementary features, that is fully capable of

  16. LucY: A versatile new fluorescent reporter protein

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Auldridge, Michele E.; Cao, Hongnan; Sen, Saurabh; Franz, Laura P.; Bingman, Craig A.; Yennamalli, Ragothaman M.; Phillips, Jr., George N.; Mead, David; Steinmetz, Eric J.; Michnick, Stephen W.

    2015-04-23

    We report on the discovery, isolation, and use of a novel yellow fluorescent protein. Lucigen Yellow (LucY) binds one FAD molecule within its core, thus shielding it from water and maintaining its structure so that fluorescence is 10-fold higher than freely soluble FAD. LucY displays excitation and emission spectra characteristic of FAD, with 3 excitation peaks at 276nm, 377nm, and 460nm and a single emission peak at 530nm. These excitation and emission maxima provide the large Stokes shift beneficial to fluorescence experimentation. LucY belongs to the MurB family of UDP-N-acetylenolpyruvylglucosamine reductases. The high resolution crystal structure shows that in contrastmore » to other structurally resolved MurB enzymes, LucY does not contain a potentially quenching aromatic residue near the FAD isoalloxazine ring, which may explain its increased fluorescence over related proteins. Using E. coli as a system in which to develop LucY as a reporter, we show that it is amenable to circular permutation and use as a reporter of protein-protein interaction. Fragmentation between its distinct domains renders LucY non-fluorescent, but fluorescence can be partially restored by fusion of the fragments to interacting protein domains. Thus, LucY may find application in Protein-fragment Complementation Assays for evaluating protein-protein interactions.« less

  17. Rigidifying Fluorescent Linkers by Metal-Organic Framework Formation for Fluorescence Blue Shift and Quantum Yield Enhancement

    SciTech Connect (OSTI)

    Wei, ZW; Gu, ZY; Arvapally, RK; Chen, YP; McDougald, RN; Ivy, JF; Yakovenko, AA; Feng, DW; Omary, MA; Zhou, HC

    2014-06-11

    We demonstrate that rigidifying the structure of fluorescent linkers by structurally constraining them in metal-organic frameworks (MOFs) to control their conformation effectively tunes the fluorescence energy and enhances the quantum yield. Thus, a new tetraphenylethylene-based zirconium MOF exhibits a deep-blue fluorescent emission at 470 nm with a unity quantum yield (99.9 +/- 0.5%) under Ar, representing ca. 3600 cm(-1) blue shift and doubled radiative decay efficiency vs the linker precursor. An anomalous increase in the fluorescence lifetime and relative intensity takes place upon heating the solid MOF from cryogenic to ambient temperatures. The origin of these unusual photoluminescence properties is attributed to twisted linker conformation, intramolecular hindrance, and framework rigidity.

  18. Rigidifying Fluorescent Linkers by Metal–Organic Framework Formation for Fluorescence Blue Shift and Quantum Yield Enhancement

    SciTech Connect (OSTI)

    Wei, Zhangwen; Gu, Zhi-Yuan; Arvapally, Ravi K.; Chen, Ying-Pin; Ivy, Joshua F.; Yakovenko, Andrey A.; Feng, Dawei; Omary, Mohammad A.; Zhou, Hong-Cai

    2014-06-11

    We demonstrate that rigidifying the structure of fluorescent linkers by structurally constraining them in metal–organic frameworks (MOFs) to control their conformation effectively tunes the fluorescence energy and enhances the quantum yield. Thus, a new tetraphenylethylene-based zirconium MOF exhibits a deep-blue fluorescent emission at 470 nm with a unity quantum yield (99.9 ± 0.5%) under Ar, representing ca. 3600 cm⁻¹ blue shift and doubled radiative decay efficiency vs the linker precursor. An anomalous increase in the fluorescence lifetime and relative intensity takes place upon heating the solid MOF from cryogenic to ambient temperatures. The origin of these unusual photoluminescence properties is attributed to twisted linker conformation, intramolecular hindrance, and framework rigidity.

  19. Technical description of candidate fluorescence compounds and radioisotopes for a nuclear smuggling deterrence tag (IL500E)

    SciTech Connect (OSTI)

    Hartenstein, S.D.; Aryaeinejad, R.

    1996-03-01

    This report summarizes the efforts completed in identifying candidate fluorescence compounds and radioisotopes for a developing tagging system. The tagging system is being developed as a deterrent to nuclear smuggling, by providing a means of: (1) tracing materials and pilferers to the facility of origin for any recovered special nuclear materials; (2) inventory control of long-term stored items containing special nuclear materials; and (3) tracking materials transferred between facilities. The tagging system uses four types of tagging materials to cover a range of applications intended to prevent the pilfering of special nuclear materials. One material, fluorescent compounds which are invisible without ultraviolet or near-infrared detection systems, is marked on controlled items with a tracking pattern that corresponds to a specified item in a specified location in the data control system. The tagging system uses an invisible, fluorescent dusting powder to mark equipment and personnel who inappropriately handle the tagged material. The tagging system also uses unique combinations of radionuclides to identify the facility of origin for any special nuclear material. Currently, 18 long-lived radioisotopes, 38 short-live radioisotopes and 10 fluorescent compounds have been selected as candidate materials for the tagging system.

  20. Study: Environmental Benefits of LEDs Greater Than CFLs | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Study: Environmental Benefits of LEDs Greater Than CFLs Study: Environmental Benefits of LEDs Greater Than CFLs December 9, 2013 - 4:13pm Addthis A three-part Energy Department-funded study indicates LEDs are more environmentally friendly than compact fluorescent and incandescent lights. | Energy Department graphic A three-part Energy Department-funded study indicates LEDs are more environmentally friendly than compact fluorescent and incandescent lights. | Energy Department graphic

  1. Total reflection x-ray fluorescence: Determination of an optimum geometry

    SciTech Connect (OSTI)

    Koo, Y.M.; Chang, C.H.; Padmore, H.A.

    1997-04-01

    Total reflection X-Ray Fluorescence (TXRF) is a widely used technique in which the normal trace element detection capability of hard x-ray fluorescence (XRF) is enhanced by use of an x-ray reflective substrate. TXRF is more sensitive than normal photon induced XRF due to the reduction of the substrate scattering and fluorescence signals. This reduction comes about because in total external reflection, the photon field only penetrates about 20 {angstrom} into the surface, instead of typically 50 {mu}m for a silicon substrate at normal incidence for 10 KeV photons. The technique is used in many fields of trace element analysis, and is widely used in the determination of metal impurity concentrations on and in the surface of silicon wafers. The Semiconductor Industry Association roadmap (SIA) indicates a need for wafer contamination detection at the 10{sup 7}atoms/cm{sup 2} level in the next few years. Current commercial systems using rotating anode x-ray sources presently routinely operate with a sensitivity level of around 10{sup 10} atoms/cm{sup 2} and this has led to interest in the use of synchrotron radiation to extend the sensitivity by three orders of magnitude. The pioneering work of Pianetta and co-workers at SSRL has clearly shown that this should be possible, using a fully optimized source and detector. The purpose of this work is to determine whether ALS would be a suitable source for this type of highly sensitive wafer TXRF. At first look it appears improbable as the SSRL work used a high flux multipole wiggler source, and it is clear that the detected fluorescence for relevant concentrations is small. In addition, SSRL operates at 3.0 GeV rather than 1.9 GeV, and is therefore more naturally suited to hard x-ray experiments. The aim of this work was therefore to establish a theoretical model for the scattering and fluorescence processes, so that one could predict the differences between alternative geometries and select an optimum configuration.

  2. Cyanine-based probe\\tag-peptide pair fluorescence protein imaging and fluorescence protein imaging methods

    DOE Patents [OSTI]

    Mayer-Cumblidge, M. Uljana; Cao, Haishi

    2013-01-15

    A molecular probe comprises two arsenic atoms and at least one cyanine based moiety. A method of producing a molecular probe includes providing a molecule having a first formula, treating the molecule with HgOAc, and subsequently transmetallizing with AsCl.sub.3. The As is liganded to ethanedithiol to produce a probe having a second formula. A method of labeling a peptide includes providing a peptide comprising a tag sequence and contacting the peptide with a biarsenical molecular probe. A complex is formed comprising the tag sequence and the molecular probe. A method of studying a peptide includes providing a mixture containing a peptide comprising a peptide tag sequence, adding a biarsenical probe to the mixture, and monitoring the fluorescence of the mixture.

  3. ARM - Measurement - Cloud type

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Measurement : Cloud type Cloud type such as cirrus, stratus, cumulus etc Categories Cloud Properties Instruments The above measurement is considered scientifically relevant for the...

  4. Nuclear Resonance Fluorescence for Safeguards Applications

    SciTech Connect (OSTI)

    Ludewigt, Bernhard A; Quiter, Brian J; Ambers, Scott D

    2011-02-04

    In nuclear resonance fluorescence (NRF) measurements, resonances are excited by an external photon beam leading to the emission of {gamma} rays with specific energies that are characteristic of the emitting isotope. The promise of NRF as a non-destructive analysis technique (NDA) in safeguards applications lies in its potential to directly quantify a specific isotope in an assay target without the need for unfolding the combined responses of several fissile isotopes as often required by other NDA methods. The use of NRF for detection of sensitive nuclear materials and other contraband has been researched in the past. In the safeguards applications considered here one has to go beyond mere detection and precisely quantify the isotopic content, a challenge that is discussed throughout this report. Basic NRF measurement methods, instrumentation, and the analytical calculation of NRF signal strengths are described in Section 2. Well understood modeling and simulation tools are needed for assessing the potential of NRF for safeguards and for designing measurement systems. All our simulations were performed with the radiation transport code MCNPX, a code that is widely used in the safeguards community. Our initial studies showed that MCNPX grossly underestimated the elastically scattered background at backwards angles due to an incorrect treatment of Rayleigh scattering. While new, corrected calculations based on ENDF form factors showed much better agreement with experimental data for the elastic scattering of photons on an uranium target, the elastic backscatter is still not rigorously treated. Photonuclear scattering processes (nuclear Thomson, Delbruck and Giant Dipole Resonance scattering), which are expected to play an important role at higher energies, are not yet included. These missing elastic scattering contributions were studied and their importance evaluated evaluated against data found in the literature as discussed in Section 3. A transmission experiment

  5. Fluorescent single walled nanotube/silica composite materials

    DOE Patents [OSTI]

    Dattelbaum, Andrew M.; Gupta, Gautam; Duque, Juan G.; Doorn, Stephen K.; Hamilton, Christopher E.; DeFriend Obrey, Kimberly A.

    2013-03-12

    Fluorescent composites of surfactant-wrapped single-walled carbon nanotubes (SWNTs) were prepared by exposing suspensions of surfactant-wrapped carbon nanotubes to tetramethylorthosilicate (TMOS) vapor. Sodium deoxycholate (DOC) and sodium dodecylsulphate (SDS) were the surfactants. No loss in emission intensity was observed when the suspension of DOC-wrapped SWNTs were exposed to the TMOS vapors, but about a 50% decrease in the emission signal was observed from the SDS-wrapped SWNTs nanotubes. The decrease in emission was minimal by buffering the SDS/SWNT suspension prior to forming the composite. Fluorescent xerogels were prepared by adding glycerol to the SWNT suspensions prior to TMOS vapor exposure, followed by drying the gels. Fluorescent aerogels were prepared by replacing water in the gels with methanol and then exposing them to supercritical fluid drying conditions. The aerogels can be used for gas sensing.

  6. High lumen compact fluorescents boost light output in new fixtures

    SciTech Connect (OSTI)

    1992-12-31

    Some compact fluorescent lamps aren`t so compact. General Electric (GE), OSRAM, and Philips have been expanding offerings in longer, more powerful, hard wired CFLs that generate enough light to serve applications once limited to conventional fluorescents and metal halide systems. All three of these manufacturers have for some time offered 18- to 40-watt high-output CFLs, which use a fluorescent tube doubled back on itself to produce a lot of light in a compact source. Now GE has introduced an even larger, more powerful 50-watt unit, and OSRAM is soon to follow suit with a 55-watt lamp. These new entries to the field of turbocharged CFLs can provide general lighting at ceiling heights of 12 feet or more as well as indirect lighting, floodlighting, and wall washing. They are such a concentrated source of light that they can provide the desired illumination using fewer lamps and fixtures than would be needed with competing sources.

  7. Engineering and Characterization of a Superfolder Green Fluorescent Protein

    SciTech Connect (OSTI)

    Pedelacq,J.; Cabantous, S.; Tran, T.; Terwilliger, T.; Waldo, G.

    2006-01-01

    Existing variants of green fluorescent protein (GFP) often misfold when expressed as fusions with other proteins. We have generated a robustly folded version of GFP, called 'superfolder' GFP, that folds well even when fused to poorly folded polypeptides. Compared to 'folding reporter' GFP, a folding-enhanced GFP containing the 'cycle-3' mutations and the 'enhanced GFP' mutations F64L and S65T, superfolder GFP shows improved tolerance of circular permutation, greater resistance to chemical denaturants and improved folding kinetics. The fluorescence of Escherichia coli cells expressing each of eighteen proteins from Pyrobaculum aerophilum as fusions with superfolder GFP was proportional to total protein expression. In contrast, fluorescence of folding reporter GFP fusion proteins was strongly correlated with the productive folding yield of the passenger protein. X-ray crystallographic structural analyses helped explain the enhanced folding of superfolder GFP relative to folding reporter GFP.

  8. Biochip Image Grid Normalization Absolute Signal Fluorescence Measurement Using

    Energy Science and Technology Software Center (OSTI)

    2001-04-17

    This software was developed to measure absolute fluorescent intensities of gel pads on a microchip in units defined by a standard fluorescent slide. It can accomodate varying measurement conditions (e.g. exposure time, sensitivity of detector, resolution of detector, etc.) as well as fluorescent microscopes with non-uniform sensitivity across their field of view allowing the user to compare measurements done on different detectors with varying exposure times, sensitivities, and resolutions. The software is designed both tomore » operate Roper Scientific, Inc. cameras and to use image files produced by the program supplied with that equipment for its calculations. the intensity of the gel pad signal is computed so as to reduce background influence.« less

  9. Laser-induced differential normalized fluorescence method for cancer diagnosis

    DOE Patents [OSTI]

    Vo-Dinh, Tuan; Panjehpour, Masoud; Overholt, Bergein F.

    1996-01-01

    An apparatus and method for cancer diagnosis are disclosed. The diagnostic method includes the steps of irradiating a tissue sample with monochromatic excitation light, producing a laser-induced fluorescence spectrum from emission radiation generated by interaction of the excitation light with the tissue sample, and dividing the intensity at each wavelength of the laser-induced fluorescence spectrum by the integrated area under the laser-induced fluorescence spectrum to produce a normalized spectrum. A mathematical difference between the normalized spectrum and an average value of a reference set of normalized spectra which correspond to normal tissues is calculated, which provides for amplifying small changes in weak signals from malignant tissues for improved analysis. The calculated differential normalized spectrum is correlated to a specific condition of a tissue sample.

  10. Laser-induced differential normalized fluorescence method for cancer diagnosis

    DOE Patents [OSTI]

    Vo-Dinh, T.; Panjehpour, M.; Overholt, B.F.

    1996-12-03

    An apparatus and method for cancer diagnosis are disclosed. The diagnostic method includes the steps of irradiating a tissue sample with monochromatic excitation light, producing a laser-induced fluorescence spectrum from emission radiation generated by interaction of the excitation light with the tissue sample, and dividing the intensity at each wavelength of the laser-induced fluorescence spectrum by the integrated area under the laser-induced fluorescence spectrum to produce a normalized spectrum. A mathematical difference between the normalized spectrum and an average value of a reference set of normalized spectra which correspond to normal tissues is calculated, which provides for amplifying small changes in weak signals from malignant tissues for improved analysis. The calculated differential normalized spectrum is correlated to a specific condition of a tissue sample. 5 figs.

  11. Fluorescence spectra and biological activity of aerosolized bacillus spores and MS2 bacteriophage exposed to ozone at different relative humidities in a rotating drum

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Ratnesar-Shumate, Shanna; Pan, Yong-Le; Hill, Steven C.; Kinahan, Sean; Corson, Elizabeth; Eshbaugh, Jonathan; Santarpia, Joshua L.

    2015-10-14

    Biological aerosols (bioaerosols) released into the environment may undergo physical and chemical transformations when exposed to atmospheric constituents such as solar irradiation, reactive oxygenated species, ozone, free radicals, water vapor and pollutants. Aging experiments were performed in a rotating drum chamber subjecting bioaerosols, Bacillus thuringiensis Al Hakam (BtAH) spores and MS2 bacteriophages to ozone at 0 and 150 ppb, and relative humidities (RH) at 10%, 50%, and 80+%. Fluorescence spectra and intensities of the aerosols as a function of time in the reaction chamber were measured with a single particle fluorescence spectrometer (SPFS) and an Ultra-Violet Aerodynamic Particle Sizer® Spectrometermore » (UV-APS). Losses in biological activity were measured by culture and quantitative polymerase chain reaction (q-PCR) assay. For both types of aerosols the largest change in fluorescence emission was between 280 and 400 nm when excited at 263 nm followed by fluorescence emission between 380 and 700 nm when excited at 351 nm. The fluorescence for both BtAH and MS2 were observed to decrease significantly at high ozone concentration and high RH when excited at 263 nm excitation. The decreases in 263 nm excited fluorescence are indicative of hydrolysis and oxidation of tryptophan in the aerosols. Fluorescence measured with the UV-APS (355-nm excitation) increased with time for both BtAH and MS2 aerosols. A two log loss of MS2 bacteriophage infectivity was observed in the presence of ozone at ~50% and 80% RH when measured by culture and normalized for physical losses by q-PCR. Viability of BtAH spores after exposure could not be measured due to the loss of genomic material during experiments, suggesting degradation of extracelluar DNA attributable to oxidation. The results of these studies indicate that the physical and biological properties of bioaerosols change significantly after exposure to ozone and water vapor.« less

  12. Fluorescence spectra and biological activity of aerosolized bacillus spores and MS2 bacteriophage exposed to ozone at different relative humidities in a rotating drum

    SciTech Connect (OSTI)

    Ratnesar-Shumate, Shanna; Pan, Yong-Le; Hill, Steven C.; Kinahan, Sean; Corson, Elizabeth; Eshbaugh, Jonathan; Santarpia, Joshua L.

    2015-10-14

    Biological aerosols (bioaerosols) released into the environment may undergo physical and chemical transformations when exposed to atmospheric constituents such as solar irradiation, reactive oxygenated species, ozone, free radicals, water vapor and pollutants. Aging experiments were performed in a rotating drum chamber subjecting bioaerosols, Bacillus thuringiensis Al Hakam (BtAH) spores and MS2 bacteriophages to ozone at 0 and 150 ppb, and relative humidities (RH) at 10%, 50%, and 80+%. Fluorescence spectra and intensities of the aerosols as a function of time in the reaction chamber were measured with a single particle fluorescence spectrometer (SPFS) and an Ultra-Violet Aerodynamic Particle Sizer® Spectrometer (UV-APS). Losses in biological activity were measured by culture and quantitative polymerase chain reaction (q-PCR) assay. For both types of aerosols the largest change in fluorescence emission was between 280 and 400 nm when excited at 263 nm followed by fluorescence emission between 380 and 700 nm when excited at 351 nm. The fluorescence for both BtAH and MS2 were observed to decrease significantly at high ozone concentration and high RH when excited at 263 nm excitation. The decreases in 263 nm excited fluorescence are indicative of hydrolysis and oxidation of tryptophan in the aerosols. Fluorescence measured with the UV-APS (355-nm excitation) increased with time for both BtAH and MS2 aerosols. A two log loss of MS2 bacteriophage infectivity was observed in the presence of ozone at ~50% and 80% RH when measured by culture and normalized for physical losses by q-PCR. Viability of BtAH spores after exposure could not be measured due to the loss of genomic material during experiments, suggesting degradation of extracelluar DNA attributable to oxidation. The results of these studies indicate that the physical and biological properties of bioaerosols change significantly after exposure to ozone and water vapor.

  13. Fluorescence dye tagging scheme for mercury quantification and speciation

    DOE Patents [OSTI]

    Jiao, Hong; Catterall, Hannah

    2015-09-22

    A fluorescent dye or fluorophore capable of forming complexes with mercury comprises 6,8-difluoro-7-hydroxy-2-oxo-2H-chromene-3-carboxylate amide, wherein the amide is formed by reacting the succinimidyl ester (Pacific Blue.TM.) with an amino acid containing a thiol group, such as cysteine or glutathione. Mercury complexes of the fluorophore fluoresce when excited by a UV or violet laser diode, and the detected intensity can be calibrated to quantify the concentration of mercury in a sample reacted with the fluorophore.

  14. Heat transfer assembly for a fluorescent lamp and fixture

    DOE Patents [OSTI]

    Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.

    1992-12-29

    In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.

  15. Heat transfer assembly for a fluorescent lamp and fixture

    DOE Patents [OSTI]

    Siminovitch, Michael J.; Rubenstein, Francis M.; Whitman, Richard E.

    1992-01-01

    In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure.

  16. Digital optical phase conjugation of fluorescence in turbid tissue

    SciTech Connect (OSTI)

    Vellekoop, Ivo M.; Cui Meng; Yang Changhuei

    2012-08-20

    We demonstrate a method for phase conjugating fluorescence. Our method, called reference free digital optical phase conjugation, can conjugate extremely weak, incoherent optical signals. It was used to phase conjugate fluorescent light originating from a bead covered with 0.5 mm of light-scattering tissue. The phase conjugated beam refocuses onto the bead and causes a local increase of over two orders of magnitude in the light intensity. Potential applications are in imaging, optical trapping, and targeted photochemical activation inside turbid tissue.

  17. Synchrotron Radiation {mu}-X Ray Fluorescence on Multicellular Tumor Spheroids

    SciTech Connect (OSTI)

    Burattini, E.; Cinque, G.; Bellisola, G.; Fracasso, G.; Colombatti, M.; Monti, F.

    2003-01-24

    Synchrotron Radiation micro X-Ray Fluorescence (SR {mu}-XRF) was applied for the first time to map the trace element content on Multicellular Tumor Spheroids (MTS), i.e. human cell clusters used as an in vitro model for testing micrometastases responses to antitumoral drugs. In particular, immunotoxin molecules composed of a carrier protein (Transferrin) bound to a powerful cytotoxin (Ricin A), were here considered as representatives of a class of therapheutic macromolecules used in cancer theraphy. Spheroids included in polyacrylamide gel and placed inside quartz capillaries were studied at the ESRF ID22 beamline using a 15 keV monochromatic photon microbeam. Elemental maps (of Fe, Cu, Zn and Pb) on four groups of spheroids grown under different conditions were studied: untreated, treated only with the carrier molecule or with the toxin alone, and with the complete immunotoxin molecule (carrier+toxin). The results indicate that the distribution of Zn and, to some extent, Cu in the spheroid cells is homogeneous and independent of the treatment type. Total Reflection X-Ray Fluorescence (TR-XRF) was also applied to quantify the average trace element content in the spheroids. Future developments of the technique are finally outlined on the basis of these preliminary results.

  18. 3D optical sectioning with a new hyperspectral confocal fluorescence imaging system.

    SciTech Connect (OSTI)

    Nieman, Linda T.; Sinclair, Michael B.; Davidson, George S.; Van Benthem, Mark Hilary; Haaland, David Michael; Timlin, Jerilyn Ann; Sasaki, Darryl Yoshio; Bachand, George David; Jones, Howland D. T.

    2007-02-01

    A novel hyperspectral fluorescence microscope for high-resolution 3D optical sectioning of cells and other structures has been designed, constructed, and used to investigate a number of different problems. We have significantly extended new multivariate curve resolution (MCR) data analysis methods to deconvolve the hyperspectral image data and to rapidly extract quantitative 3D concentration distribution maps of all emitting species. The imaging system has many advantages over current confocal imaging systems including simultaneous monitoring of numerous highly overlapped fluorophores, immunity to autofluorescence or impurity fluorescence, enhanced sensitivity, and dramatically improved accuracy, reliability, and dynamic range. Efficient data compression in the spectral dimension has allowed personal computers to perform quantitative analysis of hyperspectral images of large size without loss of image quality. We have also developed and tested software to perform analysis of time resolved hyperspectral images using trilinear multivariate analysis methods. The new imaging system is an enabling technology for numerous applications including (1) 3D composition mapping analysis of multicomponent processes occurring during host-pathogen interactions, (2) monitoring microfluidic processes, (3) imaging of molecular motors and (4) understanding photosynthetic processes in wild type and mutant Synechocystis cyanobacteria.

  19. Fluorescent lamp with static magnetic field generating means

    DOE Patents [OSTI]

    Moskowitz, P.E.; Maya, J.

    1987-09-08

    A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed. 2 figs.

  20. An Analog Filter Approach to Frequency Domain Fluorescence Spectroscopy

    SciTech Connect (OSTI)

    Trainham, Clifford P.; O'Neill, Mary D.; McKenna, Ian J.

    2015-04-24

    The rate equations found in frequency domain fluorescence spectroscopy are the same as those found in electronics under analog filter theory. Laplace transform methods are a natural way to solve the equations, and the methods can provide solutions for arbitrary excitation functions. The fluorescence terms can be modeled as circuit components and cascaded with drive and detection electronics to produce a global transfer function. Electronics design tools such as Spicea can be used to model fluorescence problems. In applications, such as remote sensing, where detection electronics are operated at high gain and limited bandwidth, a global modeling of the entire system is important, since the filter terms of the drive and detection electronics affect the measured response of the fluorescence signals. The techniques described here can be used to separate signals from fast and slow fluorophores emitting into the same spectral band, and data collection can be greatly accelerated by means of a frequency comb driver waveform and appropriate signal processing of the response.

  1. An analog filter approach to frequency domain fluorescence spectroscopy

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Trainham, Clifford P.; O'Neill, Mary D.; McKenna, Ian J.

    2015-10-01

    The rate equations found in frequency domain fluorescence spectroscopy are the same as those found in electronics under analog filter theory. Laplace transform methods are a natural way to solve the equations, and the methods can provide solutions for arbitrary excitation functions. The fluorescence terms can be modeled as circuit components and cascaded with drive and detection electronics to produce a global transfer function. Electronics design tools such as Spicea can be used to model fluorescence problems. In applications, such as remote sensing, where detection electronics are operated at high gain and limited bandwidth, a global modeling of the entiremore » system is important, since the filter terms of the drive and detection electronics affect the measured response of the fluorescence signals. Furthermore, the techniques described here can be used to separate signals from fast and slow fluorophores emitting into the same spectral band, and data collection can be greatly accelerated by means of a frequency comb driver waveform and appropriate signal processing of the response.« less

  2. Fluorescence photon migration by the boundary element method

    SciTech Connect (OSTI)

    Fedele, Francesco; Eppstein, Margaret J. . E-mail: maggie.eppstein@uvm.edu; Laible, Jeffrey P.; Godavarty, Anuradha; Sevick-Muraca, Eva M.

    2005-11-20

    The use of the boundary element method (BEM) is explored as an alternative to the finite element method (FEM) solution methodology for the elliptic equations used to model the generation and transport of fluorescent light in highly scattering media, without the need for an internal volume mesh. The method is appropriate for domains where it is reasonable to assume the fluorescent properties are regionally homogeneous, such as when using highly specific molecularly targeted fluorescent contrast agents in biological tissues. In comparison to analytical results on a homogeneous sphere, BEM predictions of complex emission fluence are shown to be more accurate and stable than those of the FEM. Emission fluence predictions made with the BEM using a 708-node mesh, with roughly double the inter-node spacing of boundary nodes as in a 6956-node FEM mesh, match experimental frequency-domain fluorescence emission measurements acquired on a 1087 cm{sup 3} breast-mimicking phantom at least as well as those of the FEM, but require only 1/8 to 1/2 the computation time.

  3. Automated hybridization/imaging device for fluorescent multiplex DNA sequencing

    DOE Patents [OSTI]

    Weiss, R.B.; Kimball, A.W.; Gesteland, R.F.; Ferguson, F.M.; Dunn, D.M.; Di Sera, L.J.; Cherry, J.L.

    1995-11-28

    A method is disclosed for automated multiplex sequencing of DNA with an integrated automated imaging hybridization chamber system. This system comprises an hybridization chamber device for mounting a membrane containing size-fractionated multiplex sequencing reaction products, apparatus for fluid delivery to the chamber device, imaging apparatus for light delivery to the membrane and image recording of fluorescence emanating from the membrane while in the chamber device, and programmable controller apparatus for controlling operation of the system. The multiplex reaction products are hybridized with a probe, the enzyme (such as alkaline phosphatase) is bound to a binding moiety on the probe, and a fluorogenic substrate (such as a benzothiazole derivative) is introduced into the chamber device by the fluid delivery apparatus. The enzyme converts the fluorogenic substrate into a fluorescent product which, when illuminated in the chamber device with a beam of light from the imaging apparatus, excites fluorescence of the fluorescent product to produce a pattern of hybridization. The pattern of hybridization is imaged by a CCD camera component of the imaging apparatus to obtain a series of digital signals. These signals are converted by the controller apparatus into a string of nucleotides corresponding to the nucleotide sequence an automated sequence reader. The method and apparatus are also applicable to other membrane-based applications such as colony and plaque hybridization and Southern, Northern, and Western blots. 9 figs.

  4. Automated hybridization/imaging device for fluorescent multiplex DNA sequencing

    DOE Patents [OSTI]

    Weiss, Robert B.; Kimball, Alvin W.; Gesteland, Raymond F.; Ferguson, F. Mark; Dunn, Diane M.; Di Sera, Leonard J.; Cherry, Joshua L.

    1995-01-01

    A method is disclosed for automated multiplex sequencing of DNA with an integrated automated imaging hybridization chamber system. This system comprises an hybridization chamber device for mounting a membrane containing size-fractionated multiplex sequencing reaction products, apparatus for fluid delivery to the chamber device, imaging apparatus for light delivery to the membrane and image recording of fluorescence emanating from the membrane while in the chamber device, and programmable controller apparatus for controlling operation of the system. The multiplex reaction products are hybridized with a probe, then an enzyme (such as alkaline phosphatase) is bound to a binding moiety on the probe, and a fluorogenic substrate (such as a benzothiazole derivative) is introduced into the chamber device by the fluid delivery apparatus. The enzyme converts the fluorogenic substrate into a fluorescent product which, when illuminated in the chamber device with a beam of light from the imaging apparatus, excites fluorescence of the fluorescent product to produce a pattern of hybridization. The pattern of hybridization is imaged by a CCD camera component of the imaging apparatus to obtain a series of digital signals. These signals are converted by the controller apparatus into a string of nucleotides corresponding to the nucleotide sequence an automated sequence reader. The method and apparatus are also applicable to other membrane-based applications such as colony and plaque hybridization and Southern, Northern, and Western blots.

  5. Fluorescent lamp with static magnetic field generating means

    DOE Patents [OSTI]

    Moskowitz, Philip E.; Maya, Jakob

    1987-01-01

    A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed.

  6. Types of Reuse

    Broader source: Energy.gov [DOE]

    The following provides greater detail regarding the types of reuse pursued for LM sites. It should be noted that many actual reuses combine several types of the uses listed below.

  7. Types of Radiation Exposure

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    External Irradiation Contamination Incorporation Biological Effects of Acute, Total Body Irradiation Managing Radiation Emergencies Procedure Demonstration Types of radiation ...

  8. Postdoc Appointment Types

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Appointment Types Postdoc Appointment Types Most postdocs will be offered a postdoctoral research associate appointment. Each year, approximately 30 Postdoctoral Fellow appointments, including the Distinguished Fellows, are awarded. Postdoc appointment types offer world of possibilities Meet the current LANL Distinguished Postdocs Research Associates Research Associates pursue research as part of ongoing LANL science and engineering programs. Sponsored postdoctoral candidate packages are

  9. Ruby and Sm:YAG fluorescence pressure gauges up to 120 GPa and...

    Office of Scientific and Technical Information (OSTI)

    Ruby and Sm:YAG fluorescence pressure gauges up to 120 GPa and 700 K Citation Details In-Document Search Title: Ruby and Sm:YAG fluorescence pressure gauges up to 120 GPa and 700 K ...

  10. DNA complexes with dyes designed for energy transfer as fluorescent markers

    DOE Patents [OSTI]

    Glazer, A.N.; Benson, S.C.

    1995-03-28

    Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated. 4 figures.

  11. DNA complexes with dyes designed for energy transfer as fluorescent markers

    DOE Patents [OSTI]

    Glazer, Alexander N.; Benson, Scott C.

    1997-01-01

    Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.

  12. DNA complexes with dyes designed for energy transfer as fluorescent markers

    DOE Patents [OSTI]

    Glazer, Alexander M.; Benson, Scott C.

    1999-01-01

    Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.

  13. DNA complexes with dyes designed for energy transfer as fluorescent markers

    DOE Patents [OSTI]

    Glazer, Alexander N.; Benson, Scott C.

    1995-01-01

    Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.

  14. DNA complexes with dyes designed for energy transfer as fluorescent markers

    DOE Patents [OSTI]

    Glazer, A.N.; Benson, S.C.

    1997-07-08

    Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated. 4 figs.

  15. DNA complexes with dyes designed for energy transfer as fluorescent markers

    DOE Patents [OSTI]

    Glazer, A.M.; Benson, S.C.

    1998-06-16

    Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated. 4 figs.

  16. DNA complexes with dyes designed for energy transfer as fluorescent markers

    DOE Patents [OSTI]

    Glazer, Alexander M.; Benson, Scott C.

    1998-01-01

    Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.

  17. Exchange of Type II Dockerin-Containing Subunits of the C. thermocellum Cellulosome as Revealed by SNAP-tags

    SciTech Connect (OSTI)

    Waller, Benjamin; Olson, Daniel G.; Currie, Devin; Guss, Adam M; Lynd, Lee R

    2013-01-01

    Clostridium thermocellum is a thermophilic anaerobic bacterium which efficiently hydrolyzes and metabolizes cellulose to ethanol through the action of its cellulosome, a multiprotein enzymatic complex. A fluorescent protein probe, consisting of a type II dockerin module fused to a SNAP-tag, was developed in order to gain insight into the quaternary configuration of the cellulosome and to investigate the effect of deleting cipA, the protein scaffold on which the cellulosome is built. Fluorescence microscopy suggested that the probe had localized to polycellulosomal protuberances on the cell surface. Surprisingly, fluorescence intensity did not substantially change in the cipA deletion mutants. Sequential labeling experiments suggested that this was a result of bound type II dockerins from CipA being replaced by unbound type II dockerins from the fluorophore-SNAP-XDocII probe. This mechanism of dockerin exchange could represent an efficient means for modifying cellulosome composition.

  18. Fluorescence-based video profile beam diagnostics: Theory and experience

    SciTech Connect (OSTI)

    Sandoval, D.; Gilpatrick, D.; Shinas, M.; Garcia, R.; Yuan, V.; Zander, M.

    1994-05-01

    Inelastic collisions between accelerated particles and residual gas in the accelerator vessel can cause the residual gas to fluoresce. The gas fluorescence intensity is proportional to the current density of the particle beam. This process provides the foundation for a video diagnostic system to measure the profile and position of accelerated particle beams. This, in fact, has proven to be a useful diagnostic at several installations. This paper describes the light production process resulting from beam -- residual gas interactions and gives formulas for estimating the beam radiance for various conditions. Ground Test Accelerator (GTA) radiance calculations will be used as an example. In addition, measurement experiences with the GTA video diagnostics system will be discussed.

  19. Fluorescence-based video profile beam diagnostics: Theory and experience

    SciTech Connect (OSTI)

    Sandoval, D.P.; Garcia, R.C.; Gilpatrick, J.D.; Shinas, M.A.; Wright, R.; Yuan, V.; Zander, M.E. )

    1994-10-10

    Inelastic collisions between accelerated particles and residual gas in the accelerator vessel can cause the residual gas to fluoresce. The gas fluorescence intensity is proportional to the current density of the particle beam. This process provides the foundation for a video diagnostics system to measure the profile and position of accelerated particle beams. This, in fact, has proven to be a useful diagnostic at several installations. This paper describes the light production process resulting from beam-residual gas interactions and gives formulas for estimating the beam radiance for various conditions. Ground Test Accelerator (GTA) radiance calculations will be used as an example. In addition, measurement experiences with the GTA video diagnostics system will be discussed.

  20. Development of real time detector for fluorescent particles

    SciTech Connect (OSTI)

    Prevost, C.; Vendel, J.; Seigneur, A.

    1997-08-01

    Aerosols tagged by a fluorescent dye are a worthwhile tool within the framework of ventilation and filtration studies. The detection in real time of a specific particulate tracer allows characterization of ventilation behaviour such as air change rate, the determination of a good or bad mixing zone and transfer coefficient, or the determination of the decontamination factor for High Efficiency Particulate Air (HEPA) filters. Generally, these tests require specific aerosols in order to get rid of the atmospheric aerosol background. Until now the principle of fluorescent aerosol concentration measuring has only allowed an integral response with a time lag by means of sampling on filters and a fluorimetric analysis after specific conditioning of these filters. 5 refs., 13 figs.

  1. DNA fragment sizing and sorting by laser-induced fluorescence

    DOE Patents [OSTI]

    Hammond, Mark L.; Jett, James H.; Keller, Richard A.; Marrone, Babetta L.; Martin, John C.

    1996-01-01

    A method is provided for sizing DNA fragments using high speed detection systems, such as flow cytometry to determine unique characteristics of DNA pieces from a sample. In one characterization the DNA piece is fragmented at preselected sites to produce a plurality of DNA fragments. The DNA piece or the resulting DNA fragments are treated with a dye effective to stain stoichiometrically the DNA piece or the DNA fragments. The fluorescence from the dye in the stained fragments is then examined to generate an output functionally related to the number of nucleotides in each one of the DNA fragments. In one embodiment, the intensity of the fluorescence emissions from each fragment is linearly related to the fragment length. The distribution of DNA fragment sizes forms a characterization of the DNA piece for use in forensic and research applications.

  2. Rotational order–disorder structure of fluorescent protein FP480

    SciTech Connect (OSTI)

    Pletnev, Sergei; Morozova, Kateryna S.; Verkhusha, Vladislav V.; Dauter, Zbigniew

    2009-09-01

    An analysis of the rotational order–disorder structure of fluorescent protein FP480 is presented. In the last decade, advances in instrumentation and software development have made crystallography a powerful tool in structural biology. Using this method, structural information can now be acquired from pathological crystals that would have been abandoned in earlier times. In this paper, the order–disorder (OD) structure of fluorescent protein FP480 is discussed. The structure is composed of tetramers with 222 symmetry incorporated into the lattice in two different ways, namely rotated 90° with respect to each other around the crystal c axis, with tetramer axes coincident with crystallographic twofold axes. The random distribution of alternatively oriented tetramers in the crystal creates a rotational OD structure with statistically averaged I422 symmetry, although the presence of very weak and diffuse additional reflections suggests that the randomness is only approximate.

  3. Magnetic fluorescent lamp having reduced ultraviolet self-absorption

    DOE Patents [OSTI]

    Berman, Samuel M.; Richardson, Robert W.

    1985-01-01

    The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly (10) is enhanced by providing means (30) for establishing a magnetic field with lines of force along the path of electron flow through the bulb (12) of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

  4. Contraband Detection with Nuclear Resonance Fluorescence: Feasibility and Impact

    SciTech Connect (OSTI)

    Pruet, J; Lange, D

    2007-01-03

    In this report they show that cargo interrogation systems developed to thwart trafficking of illicit nuclear materials could also be powerful tools in the larger fight against contraband smuggling. In particular, in addition to detecting special nuclear materials, cargo scanning systems that exploit nuclear resonance fluorescence to detect specific isotopes can be used to help find: chemical weapons; some drugs as well as some chemicals regulated under the controlled substances act; precious metals; materials regulated under export control laws; and commonly trafficked fluorocarbons.

  5. Operating temperatures of recessed fluorescent fixtures with thermal insulation

    SciTech Connect (OSTI)

    Yarbrough, D.W.; Toor, I.A.

    1981-05-01

    Tests were performed to determine steady state surface temperatures for recessed fluorescent fixtures operated with and without thermal insulation on the top side of the fixture and to identify potential problems associated with the installation of thermal insulation. In addition to measuring temperatures, means were sought by which the fixtures can be thermally insulated and operated without fire hazards or damage to the fixture. (MCW)

  6. Enhanced detection of fluorescence quenching in labeled cells

    DOE Patents [OSTI]

    Crissman, Harry A.; Steinkamp, John A.

    1992-01-01

    A method is provided for quantifying BrdU labeled DNA in cells. The BrdU is incorporated into the DNA and the DNA is stained with a first fluorochrome having a fluorescence which is quenchable by BrdU. The first fluorochrome is preferably a thymidine base halogen analogue, such as a Hoechst fluorochrome. The DNA is then stained with a second fluorochrome having a fluorescence that is substantially uneffected by BrdU. The second fluorochrome may be selected from the group consisting of mithramycin, chromomycin A3, olivomycin, propidium iodide and ethidium bromine. The fluorescence from the first and second fluorochromes is then measured to obtain first and second output signals, respectively. The first output signal is substracted from the second output signal to obtain a difference signal which is functionally related to the quantity of BrdU incorporated into DNA. The technique is particularly useful for quantifying the synthesis of DNA during the S-phase of the cell cycle.

  7. Enhanced detection of fluorescence quenching in labeled cells

    DOE Patents [OSTI]

    Crissman, H.A.; Steinkamp, J.A.

    1987-11-30

    A method is provided for quantifying BrdU labeled DNA in cells. The BrdU is substituted onto the DNA and the DNA is stained with a first fluorochrome having a fluorescence which is quenchable by BrdU. The first fluorochrome is preferably a thymidine base halogen analogue, such as a Hoechst fluorochrome. The DNA is then stained with a second fluorochrome having a fluorescence which is substantially uneffected by BrdU. The second fluorochrome may be selected from the group consisting of mithramycin, chromomycin A3, olivomycin, propidium iodide and ethidium bromine. The fluorescence from the first and second fluorochromes is then measured to obtain first and second output signals, respectively. The first output signal is subtracted from the second output signal to obtain a difference signal which is functionally related to the quantity of BrdU incorporated into DNA. The technique is particularly useful for quantifying the synthesis of DNA during the S-phase of the cell cycle. 2 figs.

  8. The use of fluorescent compounds and complexes of metals as early warning detectors for corrosion

    SciTech Connect (OSTI)

    Johnson, R.E.; Agarwala, V.S.

    1994-12-31

    Several compounds have been identified which change their fluorescent behavior upon oxidation or reduction. These compounds have been investigated to determine the effects of temperature, pH, reduction conditions and re-oxidation behavior on their fluorescence. They have been incorporated into primer paint coatings for aluminum alloys and were found to fluoresce if the coating was scratched and exposed to air and moisture. Another compound was found to fluoresce with aluminum ions and its fluorescence behavior with varying conditions was also investigated. This compound, if added to a primer coating on an aluminum alloy, should fluoresce when aluminum ions begin to form as the alloy corrodes. Both of these methods appear to have potential to be early warning sensors for corrosion. Large surface areas of alloy material, such as are used in aircraft, could be scanned with UV light to detect the fluorescence of these materials indicating possible corrosion sites.

  9. Proton-induced x-ray fluorescence CT imaging

    SciTech Connect (OSTI)

    Bazalova-Carter, Magdalena Xing, Lei; Ahmad, Moiz; Matsuura, Taeko; Takao, Seishin; Shirato, Hiroki; Umegaki, Kikuo; Matsuo, Yuto; Fahrig, Rebecca

    2015-02-15

    Purpose: To demonstrate the feasibility of proton-induced x-ray fluorescence CT (pXFCT) imaging of gold in a small animal sized object by means of experiments and Monte Carlo (MC) simulations. Methods: First, proton-induced gold x-ray fluorescence (pXRF) was measured as a function of gold concentration. Vials of 2.2 cm in diameter filled with 0%–5% Au solutions were irradiated with a 220 MeV proton beam and x-ray fluorescence induced by the interaction of protons, and Au was detected with a 3 × 3 mm{sup 2} CdTe detector placed at 90° with respect to the incident proton beam at a distance of 45 cm from the vials. Second, a 7-cm diameter water phantom containing three 2.2-diameter vials with 3%–5% Au solutions was imaged with a 7-mm FWHM 220 MeV proton beam in a first generation CT scanning geometry. X-rays scattered perpendicular to the incident proton beam were acquired with the CdTe detector placed at 45 cm from the phantom positioned on a translation/rotation stage. Twenty one translational steps spaced by 3 mm at each of 36 projection angles spaced by 10° were acquired, and pXFCT images of the phantom were reconstructed with filtered back projection. A simplified geometry of the experimental data acquisition setup was modeled with the MC TOPAS code, and simulation results were compared to the experimental data. Results: A linear relationship between gold pXRF and gold concentration was observed in both experimental and MC simulation data (R{sup 2} > 0.99). All Au vials were apparent in the experimental and simulated pXFCT images. Specifically, the 3% Au vial was detectable in the experimental [contrast-to-noise ratio (CNR) = 5.8] and simulated (CNR = 11.5) pXFCT image. Due to fluorescence x-ray attenuation in the higher concentration vials, the 4% and 5% Au contrast were underestimated by 10% and 15%, respectively, in both the experimental and simulated pXFCT images. Conclusions: Proton-induced x-ray fluorescence CT imaging of 3%–5% gold solutions in a

  10. Parents and Kids: Energize Your Summer | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Did you know: Incandescent light bulbs only convert about 10 percent of the energy they consume into light and the rest is released as heat. The Energy Department's Energy Bike demonstrates the physical effort it takes to power incandescent, compact fluorescent and LED light bulbs. Students from Churchill Road Elementary School in Virginia recently pedaled for power at their Earth Day assembly, learning firsthand about energy efficiency. | Photo courtesy of the Energy Department. Did you know:

  11. Office Energy Checklist | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Office Energy Checklist Office Energy Checklist This checklist outlines actions that conserve energy at the office. Checkbox Replace incandescent lights with compact fluorescent lights (CFLs) or light-emitting diodes (LEDs) for desk lamps and overhead lighting. Using CFLs instead of comparable incandescent bulbs can save about 50% on your lighting costs. CFLs use only one-fourth the energy and last up to 10 times longer. Checkbox Switch off all unnecessary lights. Use dimmers, motion sensors, or

  12. ISSUANCE 2014-12-29: Energy Conservation Program: Clarification for Energy Conservation Standards and Test Procedures for Fluorescent Lamp Ballasts

    Office of Energy Efficiency and Renewable Energy (EERE)

    Energy Conservation Program: Clarification for Energy Conservation Standards and Test Procedures for Fluorescent Lamp Ballasts

  13. ISSUANCE 2016-03-24: Energy Conservation Program: Clarification of Test Procedures for Fluorescent Lamps Ballasts, Final Rule

    Office of Energy Efficiency and Renewable Energy (EERE)

    Energy Conservation Program: Clarification of Test Procedures for Fluorescent Lamps Ballasts, Final Rule

  14. Efficient and dynamic nuclear localization of green fluorescent protein via RNA binding

    SciTech Connect (OSTI)

    Kitamura, Akira; Nakayama, Yusaku; Kinjo, Masataka

    2015-07-31

    Classical nuclear localization signal (NLS) sequences have been used for artificial localization of green fluorescent protein (GFP) in the nucleus as a positioning marker or for measurement of the nuclear-cytoplasmic shuttling rate in living cells. However, the detailed mechanism of nuclear retention of GFP-NLS remains unclear. Here, we show that a candidate mechanism for the strong nuclear retention of GFP-NLS is via the RNA-binding ability of the NLS sequence. GFP tagged with a classical NLS derived from Simian virus 40 (GFP-NLS{sup SV40}) localized not only in the nucleoplasm, but also to the nucleolus, the nuclear subdomain in which ribosome biogenesis takes place. GFP-NLS{sup SV40} in the nucleolus was mobile, and intriguingly, the diffusion coefficient, which indicates the speed of diffusing molecules, was 1.5-fold slower than in the nucleoplasm. Fluorescence correlation spectroscopy (FCS) analysis showed that GFP-NLS{sup SV40} formed oligomers via RNA binding, the estimated molecular weight of which was larger than the limit for passive nuclear export into the cytoplasm. These findings suggest that the nuclear localization of GFP-NLS{sup SV40} likely results from oligomerization mediated via RNA binding. The analytical technique used here can be applied for elucidating the details of other nuclear localization mechanisms, including those of several types of nuclear proteins. In addition, GFP-NLS{sup SV40} can be used as an excellent marker for studying both the nucleoplasm and nucleolus in living cells. - Highlights: • Nuclear localization signal-tagged GFP (GFP-NLS) showed clear nuclear localization. • The GFP-NLS dynamically localized not only in the nucleoplasm, but also to the nucleolus. • The nuclear localization of GFP-NLS results from transient oligomerization mediated via RNA binding. • Our NLS-tagging procedure is ideal for use in artificial sequestration of proteins in the nucleus.

  15. Occupational exposure in the fluorescent lamp recycling sector in France

    SciTech Connect (OSTI)

    Zimmermann, François Lecler, Marie-Thérèse; Clerc, Frédéric; Chollot, Alain; Silvente, Eric; Grosjean, Jérome

    2014-07-15

    Highlights: • Chemical risks were assessed in the five fluorescent lamp recycling facilities. • The main hazardous agents are mercury vapors and dust containing lead and yttrium. • Exposure and pollutant levels were correlated with steps and processes. • All the stages and processes are concerned by worrying levels of pollutants. • We suggest recommendations to reduce chemical risk. - Abstract: The fluorescent lamp recycling sector is growing considerably in Europe due to increasingly strict regulations aimed at inciting the consumption of low energy light bulbs and their end-of-life management. Chemical risks were assessed in fluorescent lamp recycling facilities by field measurement surveys in France, highlighting that occupational exposure and pollutant levels in the working environment were correlated with the main recycling steps and processes. The mean levels of worker exposure are 4.4 mg/m{sup 3}, 15.4 μg/m{sup 3}, 14.0 μg/m{sup 3}, 247.6 μg/m{sup 3}, respectively, for total inhalable dust, mercury, lead and yttrium. The mean levels of airborne pollutants are 3.1 mg/m{sup 3}, 9.0 μg/m{sup 3}, 9.0 μg/m{sup 3}, 219.2 μg/m{sup 3}, respectively, for total inhalable dust, mercury, lead and yttrium. The ranges are very wide. Surface samples from employees’ skin and granulometric analysis were also carried out. The overview shows that all the stages and processes involved in lamp recycling are concerned by the risk of hazardous substances penetrating into the bodies of employees, although exposure of the latter varies depending on the processes and tasks they perform. The conclusion of this study strongly recommends the development of a new generation of processes in parallel with more information sharing and regulatory measures.

  16. Blue-green phosphor for fluorescent lighting applications

    DOE Patents [OSTI]

    Srivastava, Alok; Comanzo, Holly; Manivannan, Venkatesan; Setlur, Anant Achyut

    2005-03-15

    A fluorescent lamp including a phosphor layer including Sr.sub.4 Al.sub.14 O.sub.25 :Eu.sup.2+ (SAE) and at least one of each of a red, green and blue emitting phosphor. The phosphor layer can optionally include an additional, deep red phosphor and a yellow emitting phosphor. The resulting lamp will exhibit a white light having a color rendering index of 90 or higher with a correlated color temperature of from 2500 to 10000 Kelvin. The use of SAE in phosphor blends of lamps results in high CRI light sources with increased stability and acceptable lumen maintenance over, the course of the lamp life.

  17. Evaluating the variability of ceramics with x-ray fluorescence

    SciTech Connect (OSTI)

    Crown, P.L.; Schwalbe, L.A.; London, J.R.

    1984-01-01

    Our assessment of prehistoric trade in ceramics depends on our ability to identify and distinguish different sources of manufacture. For the American Southwest, archaeologists have proposed various models of ceramic manufacture and exchange. Until recently, conflicting hypotheses were tested mainly on the basis of petrographic analysis of nonplastic tempering materials. We have extended these analyses to include x-ray fluorescence (XRF). XRF provides a fast and inexpensive means of analyzing large numbers of samples. Since 1982, approximately 500 prehistoric sherds and 40 prepared clay and mineral samples have been examined with XRF. Multivariate statistical techniques have been applied to help identify groupings of samples with possible archaeological significance.

  18. A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard

    SciTech Connect (OSTI)

    Lin, Jiang

    2002-04-11

    Lighting has been one of the fastest growing electric end-uses in China over the last twenty years, with an average annual growth rate of 14%. Fluorescent lighting provides a significant portion of China's lighting need. In 1998, China produced 680 million fluorescent lamps, of which 420 million were linear fluorescent lamps of various diameters (T8 to T12). There are substantial variations both in energy efficiency and lighting performance among locally produced fluorescent lamps. Such variations present a perfect opportunity for policy intervention through efficiency standards to promote the adoption of more efficient fluorescent lamps in China. This paper analyzes China's proposed minimum efficiency standard for fluorescent lamps and presents an assessment of its likely impacts on China's lighting energy consumption and GHG emissions.

  19. Calculation of K-shell fluorescence yields for low-Z elements

    SciTech Connect (OSTI)

    Nekkab, M.; Kahoul, A.; Deghfel, B.; Aylikci, N. Küp; Aylikçi, V.

    2015-03-30

    The analytical methods based on X-ray fluorescence are advantageous for practical applications in a variety of fields including atomic physics, X-ray fluorescence surface chemical analysis and medical research and so the accurate fluorescence yields (ω{sub K}) are required for these applications. In this contribution we report a new parameters for calculation of K-shell fluorescence yields (ω{sub K}) of elements in the range of 11≤Z≤30. The experimental data are interpolated by using the famous analytical function (ω{sub k}/(1−ω{sub k})){sup 1/q} (were q=3, 3.5 and 4) vs Z to deduce the empirical K-shell fluorescence yields. A comparison is made between the results of the procedures followed here and those theoretical and other semi-empirical fluorescence yield values. Reasonable agreement was typically obtained between our result and other works.

  20. 2014-10-14 Issuance: Test Procedures Correction for Fluorescent Lamp

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Ballasts; Notice of Proposed Rulemaking | Department of Energy 4 Issuance: Test Procedures Correction for Fluorescent Lamp Ballasts; Notice of Proposed Rulemaking 2014-10-14 Issuance: Test Procedures Correction for Fluorescent Lamp Ballasts; Notice of Proposed Rulemaking This document is a pre-publication Federal Register notice of proposed rulemaking regarding test procedures for fluorescent lamp ballasts, as issued by the Deputy Assistant Secretary for Energy Efficiency on October 14,

  1. INITIAL OPERATION OF THE LEDA BEAM-INDUCED FLUORESCENCE DIAGNOSTIC

    SciTech Connect (OSTI)

    J. KAMPERSCHROER; ET AL

    2000-06-01

    A diagnostic based on beam-induced fluorescence has been developed and used to examine the expanded beam in the High-Energy Beam Transport (HEBT) section of the Low Energy Demonstration Accelerator (LEDA). The system consists of a camera, a gas injector, a spectrometer, and a control system. Gas is injected to provide a medium for the beam to excite, the camera captures the resulting image of the fluorescing gas, and the spectrometer measures the spectrum of the emitted light. EPICS was used to control the camera and acquire and store images. Data analysis is presently being performed offline. A Kodak DCS420m professional CCD camera is the primary component of the optical system. InterScience, Inc. modified the camera with the addition of a gain of 4000 image intensifier, thereby producing an intensified camera with a sensitivity of {approximately}0.5 milli-lux. Light is gathered with a 1 inch format, 16-160 mm, Computar zoom lens. This lens is attached to the camera via a Century Precision Optics relay lens. Images obtained using only hydrogen from the beam stop exhibited features not yet understood. Images with good signal-to-noise ratio were obtained with the injection of sufficient nitrogen to raise the HEBT pressure to 2-8x10{sup {minus}6} torr. Two strong nitrogen lines, believed to be of the first negative group of N{sub 2}{sup +}, were identified at 391 and 428 nm.

  2. Red phosphors for use in high CRI fluorescent lamps

    DOE Patents [OSTI]

    Srivastava, Alok; Comanzo, Holly; Manivannan, Vankatesan; Setlur, Anant Achyut

    2005-11-15

    Novel red emitting phosphors for use in fluorescent lamps resulting in superior color rendering index values compared to conventional red phosphors. Also disclosed is a fluorescent lamp including a phosphor layer comprising blends of one or more of a blue phosphor, a blue-green phosphor, a green phosphor and a red a phosphor selected from the group consisting of SrY.sub.2 O.sub.4 :Eu.sup.3+, (Y,Gd)Al.sub.3 B.sub.4 O.sub.12 :Eu.sup.3+, and [(Y.sub.1-x-y-m La.sub.y)Gd.sub.x ]BO.sub.3 :Eu.sub.m wherein y<0.50 and m=0.001-0.3. The phosphor layer can optionally include an additional deep red phosphor and a yellow emitting phosphor. The resulting lamp will exhibit a white light having a color rendering index of 90 or higher with a correlated color temperature of from 2500 to 10000 Kelvin. The use of the disclosed red phosphors in phosphor blends of lamps results in high CRI light sources with increased stability and acceptable lumen maintenance over the course of the lamp life.

  3. Protein- protein interaction detection system using fluorescent protein microdomains

    DOE Patents [OSTI]

    Waldo, Geoffrey S.; Cabantous, Stephanie

    2010-02-23

    The invention provides a protein labeling and interaction detection system based on engineered fragments of fluorescent and chromophoric proteins that require fused interacting polypeptides to drive the association of the fragments, and further are soluble and stable, and do not change the solubility of polypeptides to which they are fused. In one embodiment, a test protein X is fused to a sixteen amino acid fragment of GFP (.beta.-strand 10, amino acids 198-214), engineered to not perturb fusion protein solubility. A second test protein Y is fused to a sixteen amino acid fragment of GFP (.beta.-strand 11, amino acids 215-230), engineered to not perturb fusion protein solubility. When X and Y interact, they bring the GFP strands into proximity, and are detected by complementation with a third GFP fragment consisting of GFP amino acids 1-198 (strands 1-9). When GFP strands 10 and 11 are held together by interaction of protein X and Y, they spontaneous association with GFP strands 1-9, resulting in structural complementation, folding, and concomitant GFP fluorescence.

  4. Cerenkov emission induced by external beam radiation stimulates molecular fluorescence

    SciTech Connect (OSTI)

    Axelsson, Johan; Davis, Scott C.; Gladstone, David J.; Pogue, Brian W.

    2011-07-15

    Purpose: Cerenkov emission is induced when a charged particle moves faster than the speed of light in a given medium. Both x-ray photons and electrons produce optical Cerenkov photons in everyday radiation therapy of tissue; yet, this phenomenon has never been fully documented. This study quantifies the emissions and also demonstrates that the Cerenkov emission can excite a fluorophore, protoporphyrin IX (PpIX), embedded in biological phantoms. Methods: In this study, Cerenkov emission induced by radiation from a clinical linear accelerator is investigated. Biological mimicking phantoms were irradiated with x-ray photons, with energies of 6 or 18 MV, or electrons at energies 6, 9, 12, 15, or 18 MeV. The Cerenkov emission and the induced molecular fluorescence were detected by a camera or a spectrometer equipped with a fiber optic cable. Results: It is shown that both x-ray photons and electrons, at MeV energies, produce optical Cerenkov photons in tissue mimicking media. Furthermore, we demonstrate that the Cerenkov emission can excite a fluorophore, protoporphyrin IX (PpIX), embedded in biological phantoms. Conclusions: The results here indicate that molecular fluorescence monitoring during external beam radiotherapy is possible.

  5. Analysis of the influence of subcellular localization of the HIV Rev protein on Rev-dependent gene expression by multi-fluorescence live-cell imaging

    SciTech Connect (OSTI)

    Wolff, Horst; Hadian, Kamyar; Ziegler, Manja; Weierich, Claudia; Kramer-Hammerle, Susanne; Kleinschmidt, Andrea; Erfle, Volker; Brack-Werner, Ruth . E-mail: brack@gsf.de

    2006-02-15

    The human immunodeficiency virus Rev protein is a post-transcriptional activator of HIV gene expression. Rev is a nucleocytoplasmic shuttle protein that displays characteristic nuclear/nucleolar subcellular localization in various cell lines. Cytoplasmic localization of Rev occurs under various conditions disrupting Rev function. The goal of this study was to investigate the relationship between localization of Rev and its functional activity in living cells. A triple-fluorescent imaging assay, called AQ-FIND, was established for automatic quantitative evaluation of nucleocytoplasmic distribution of fluorescently tagged proteins. This assay was used to screen 500 rev genes generated by error-prone PCR for Rev mutants with different localization phenotypes. Activities of the Rev mutants were determined with a second quantitative, dual-fluorescent reporter assay. In HeLa cells, the majority of nuclear Rev mutants had activities similar to wild-type Rev. The activities of Rev mutants with abnormal cytoplasmic localization ranged from moderately impaired to nonfunctional. There was no linear correlation between subcellular distribution and levels of Rev activity. In astrocytes, nuclear Rev mutants showed similar impaired activities as the cytoplasmic wild-type Rev. Our data suggest that steady-state subcellular localization is not a primary regulator of Rev activity but may change as a secondary consequence of altered Rev function. The methodologies described here have potential for studying the significance of subcellular localization for functions of other regulatory factors.

  6. Excitation-emission spectra and fluorescence quantum yields for fresh and aged biogenic secondary organic aerosols

    SciTech Connect (OSTI)

    Lee, Hyun Ji; Laskin, Alexander; Laskin, Julia; Nizkorodov, Sergey A.

    2013-05-10

    Certain biogenic secondary organic aerosols (SOA) become absorbent and fluorescent when exposed to reduced nitrogen compounds such as ammonia, amines and their salts. Fluorescent SOA may potentially be mistaken for biological particles by detection methods relying on fluorescence. This work quantifies the spectral distribution and effective quantum yields of fluorescence of SOA generated from two monoterpenes, limonene and a-pinene, and two different oxidants, ozone (O3) and hydroxyl radical (OH). The SOA was generated in a smog chamber, collected on substrates, and aged by exposure to ~100 ppb ammonia vapor in air saturated with water vapor. Absorption and excitation-emission matrix (EEM) spectra of aqueous extracts of aged and control SOA samples were measured, and the effective absorption coefficients and fluorescence quantum yields (~0.005 for 349 nm excitation) were determined from the data. The strongest fluorescence for the limonene-derived SOA was observed for excitation = 420+- 50 nm and emission = 475 +- 38 nm. The window of the strongest fluorescence shifted to excitation = 320 +- 25 nm and emission = 425 +- 38 nm for the a-pinene-derived SOA. Both regions overlap with the excitation-emission matrix (EEM) spectra of some of the fluorophores found in primary biological aerosols. Our study suggests that, despite the low quantum yield, the aged SOA particles should have sufficient fluorescence intensities to interfere with the fluorescence detection of common bioaerosols.

  7. Max Tech and Beyond: Fluorescent Lamps (Technical Report) | SciTech...

    Office of Scientific and Technical Information (OSTI)

    In addition to offering the market a high-quality efficacious light source, another strong value proposition of fluorescent lighting is its long operating life. In today's market, ...

  8. Synthesis and properties of SiN coatings as stable fluorescent...

    Office of Scientific and Technical Information (OSTI)

    aligned carbon nanofibers Citation Details In-Document Search Title: Synthesis and properties of SiN coatings as stable fluorescent markers on vertically aligned carbon ...

  9. Capillary electrophoresis-fluorescence line narrowing system (CE-FLNS) for on-line structural characterization

    DOE Patents [OSTI]

    Jankowiak, R.J.; Small, G.J.; Shields, P.A.

    1999-04-27

    Capillary electrophoresis (CE) is interfaced with low temperature fluorescence line-narrowing (FLN) spectroscopy for on-line structural characterization of separated molecular analytes. 21 figs.

  10. Capillary electrophoresis-fluorescence line narrowing system (CE-FLNS) for on-line structural characterization

    DOE Patents [OSTI]

    Jankowiak, Ryszard J.; Small, Gerald J.; Shields, Peter A.

    1999-04-27

    Capillary electrophoresis (CE) is interfaced with low temperature fluorescence line-narrowing (FLN) spectroscopy for on-line structural characterization of separated molecular analytes.

  11. Nuclear Resonance Fluorescence at MIT | U.S. DOE Office of Science...

    Office of Science (SC) Website

    Resonance Fluorescence at MIT Nuclear Physics (NP) NP Home About Research Facilities Science Highlights Benefits of NP Applications of Nuclear Science Applications of Nuclear Science ...

  12. EA-1881: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts

    Broader source: Energy.gov [DOE]

    This EA evaluates the environmental impacts of a proposal to amend energy conservation standards for various consumer products and certain commercial and industrial equipment, including fluorescent lamp ballasts.

  13. Azimuthal anisotropy of the scattered radiation in grazing incidence X-ray fluorescence

    SciTech Connect (OSTI)

    Das, Gangadhar Tiwari, M. K.; Singh, A. K.; Ghosh, Haranath

    2015-06-24

    The Compton and elastic scattering radiations are the major contributor to the spectral background of an x-ray fluorescence spectrum, which eventually limits the element detection sensitivities of the technique to µg/g (ppm) range. In the present work, we provide a detail mathematical descriptions and show that how polarization properties of the synchrotron radiation influence the spectral background in the x-ray fluorescence technique. We demonstrate our theoretical understandings through experimental observations using total x-ray fluorescence measurements on standard reference materials. Interestingly, the azimuthal anisotropy of the scattered radiation is shown to have a vital role on the significance of the x-ray fluorescence detection sensitivities.

  14. Hyperspectral image reconstruction for x-ray fluorescence tomography

    SciTech Connect (OSTI)

    Grsoy, Do?a; Bier, Tekin; Lanzirotti, Antonio; Newville, Matthew G.; De Carlo, Francesco

    2015-01-01

    A penalized maximum-likelihood estimation is proposed to perform hyperspectral (spatio-spectral) image reconstruction for X-ray fluorescence tomography. The approach minimizes a Poisson-based negative log-likelihood of the observed photon counts, and uses a penalty term that has the effect of encouraging local continuity of model parameter estimates in both spatial and spectral dimensions simultaneously. The performance of the reconstruction method is demonstrated with experimental data acquired from a seed of arabidopsis thaliana collected at the 13-ID-E microprobe beamline at the Advanced Photon Source. The resulting element distribution estimates with the proposed approach show significantly better reconstruction quality than the conventional analytical inversion approaches, and allows for a high data compression factor which can reduce data acquisition times remarkably. In particular, this technique provides the capability to tomographically reconstruct full energy dispersive spectra without compromising reconstruction artifacts that impact the interpretation of results.

  15. Fluorescence Correlation Spectroscopy at Micromolar Concentrations without Optical Nanoconfinement

    SciTech Connect (OSTI)

    Laurence, Ted A.; Ly, Sonny; Bourguet, Feliza; Fischer, Nicholas O.; Coleman, Matthew A.

    2014-08-14

    Fluorescence correlation spectroscopy (FCS) is an important technique for studying biochemical interactions dynamically that may be used in vitro and in cell-based studies. It is generally claimed that FCS may only be used at nM concentrations. We show that this general consensus is incorrect and that the limitation to nM concentrations is not fundamental but due to detector limits as well as laser fluctuations. With a high count rate detector system and applying laser fluctuation corrections, we demonstrate FCS measurements up to 38 μM with the same signal-to-noise as at lower concentrations. Optical nanoconfinement approaches previously used to increase the concentration range of FCS are not necessary, and further increases above 38 μM may be expected using detectors and detector arrays with higher saturation rates and better laser fluctuation corrections. This approach greatly widens the possibilities of dynamic measurements of biochemical interactions using FCS at physiological concentrations.

  16. Hyperspectral image reconstruction for x-ray fluorescence tomography

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Grsoy, Do?a; Bier, Tekin; Lanzirotti, Antonio; Newville, Matthew G.; De Carlo, Francesco

    2015-01-01

    A penalized maximum-likelihood estimation is proposed to perform hyperspectral (spatio-spectral) image reconstruction for X-ray fluorescence tomography. The approach minimizes a Poisson-based negative log-likelihood of the observed photon counts, and uses a penalty term that has the effect of encouraging local continuity of model parameter estimates in both spatial and spectral dimensions simultaneously. The performance of the reconstruction method is demonstrated with experimental data acquired from a seed of arabidopsis thaliana collected at the 13-ID-E microprobe beamline at the Advanced Photon Source. The resulting element distribution estimates with the proposed approach show significantly better reconstruction quality than the conventional analytical inversionmoreapproaches, and allows for a high data compression factor which can reduce data acquisition times remarkably. In particular, this technique provides the capability to tomographically reconstruct full energy dispersive spectra without compromising reconstruction artifacts that impact the interpretation of results.less

  17. Semiconductor Quantum Rods as Single Molecule FluorescentBiological Labels

    SciTech Connect (OSTI)

    Fu, Aihua; Gu, Weiwei; Boussert, Benjamine; Koski, Kristie; Gerion, Daniele; Manna, Liberato; Le Gros, Mark; Larabell, Carolyn; Alivisatos, A. Paul

    2006-05-29

    In recent years, semiconductor quantum dots have beenapplied with great advantage in a wide range of biological imagingapplications. The continuing developments in the synthesis of nanoscalematerials and specifically in the area of colloidal semiconductornanocrystals have created an opportunity to generate a next generation ofbiological labels with complementary or in some cases enhanced propertiescompared to colloidal quantum dots. In this paper, we report thedevelopment of rod shaped semiconductor nanocrystals (quantum rods) asnew fluorescent biological labels. We have engineered biocompatiblequantum rods by surface silanization and have applied them fornon-specific cell tracking as well as specific cellular targeting. Theproperties of quantum rods as demonstrated here are enhanced sensitivityand greater resistance for degradation as compared to quantum dots.Quantum rods have many potential applications as biological labels insituations where their properties offer advantages over quantumdots.

  18. Agreement Type Union

    National Nuclear Security Administration (NNSA)

    Type Union Local #/Name Number of Employees Project Labor Agreement International Association of Heat and Frost Insulators and Allied Workers 135 2 International Brothehood of Boilermakers, Iron Ship Builders, Blacksmith Forgers and Helpers 92 0 International Union of Bricklayers & Allied Craftsmen 13 0 Regional Council of Carpenters 1780 & 1977 13 Operative Plasterers and Cement Mason International Association Operative Plasterers and Cement Mason International Association 1

  19. TYPE OF OPERATION

    Office of Legacy Management (LM)

    ----------------- 0 Research & Development .a Production scale testing 0 Pilat Scale 0 Bench Scale Process 0 Thearetical Studies Cl Sample 84 Analysis 0 Production *i DiaposalKitorage Cl Facility Tybe q Government Sponsored Facility Other R.L- 6:e 14 1 1 ---------- --------- I I I TYPE OF CONTRACT ~-__-----------_ fl Prime *I 0 Subcantractbr Other infuriation (i.e., L.t + fixed fee, kit price, 0 Purchase Order time k mat*iik, gtc) /I -~---------'-t-----------~- ----------II----------------

  20. Oil to soil fluorescence-a vital link

    SciTech Connect (OSTI)

    Calhoun, G.G. )

    1994-03-01

    The aromatic component in oils may prove to be the key to defining oil traps in mature basins as well as pioneer areas. This is a direct indication of vertical oil migration and can precisely duplicate the oil signature in soil samples. This study traces the changes that occur in San Andres oils over the Permian basin. The sequence of sync-scans along the Central Basin platform pictures the gradual changes in the mix of lighter aromatics in the north toward predominately heavier aromatics in the south. This change parallels decreasing depth, freshening of formations waters, and decreased gravity of the oil. A comparison of oils and their source rocks is presented for the Woodford, Pennsylvanian, and Wolfcamp generation-migration systems. The sieving effect of the source shales is evident in the higher concentrations of complex molecules retained in the source rock as compared to the resultant oils trapped in conventional reservoir rocks. Movable oil retained in the source rock is also evident using synchronous scans. Productive areas are reflected at the surface with oil to soil correlation coefficients up to 90%. Barren areas are often evident in soil samples by their close resemblance to the source rock signature. The contrast between productive and barren area is also evident in a 100+% increase in the concentration of the various families of compounds-Benzenes, Naphthalenes, Phenanthrenes-Anthracene, and compounds containing five or more aromatic rings. Any surface geochemical evaluation should include no less than three techniques, and one of these should be soil fluorescence. No other geochemical technique can identify the source of microseeping oil. Only fluorescence cannot only say [open quotes]yes[close quotes] or [open quotes]no,[close quotes] but can also name the objective horizon.

  1. Energy.gov Page Types

    Broader source: Energy.gov [DOE]

    Learn about the standard page types available in the Energy.gov Drupal content management system. For information about other available page types, or to request a new kind of page type, contact...

  2. Studies of the laser-induced fluorescence of explosives and explosive compositions.

    SciTech Connect (OSTI)

    Hargis, Philip Joseph, Jr.; Thorne, Lawrence R.; Phifer, Carol Celeste; Parmeter, John Ethan; Schmitt, Randal L.

    2006-10-01

    Continuing use of explosives by terrorists throughout the world has led to great interest in explosives detection technology, especially in technologies that have potential for standoff detection. This LDRD was undertaken in order to investigate the possible detection of explosive particulates at safe standoff distances in an attempt to identify vehicles that might contain large vehicle bombs (LVBs). The explosives investigated have included the common homogeneous or molecular explosives, 2,4,6-trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), cyclonite or hexogen (RDX), octogen (HMX), and the heterogeneous explosive, ammonium nitrate/fuel oil (ANFO), and its components. We have investigated standard excited/dispersed fluorescence, laser-excited prompt and delayed dispersed fluorescence using excitation wavelengths of 266 and 355 nm, the effects of polarization of the laser excitation light, and fluorescence imaging microscopy using 365- and 470-nm excitation. The four nitro-based, homogeneous explosives (TNT, PETN, RDX, and HMX) exhibit virtually no native fluorescence, but do exhibit quenching effects of varying magnitude when adsorbed on fluorescing surfaces. Ammonium nitrate and fuel oil mixtures fluoresce primarily due to the fuel oil, and, in some cases, due to the presence of hydrophobic coatings on ammonium nitrate prill or impurities in the ammonium nitrate itself. Pure ammonium nitrate shows no detectable fluorescence. These results are of scientific interest, but they provide little hope for the use of UV-excited fluorescence as a technique to perform safe standoff detection of adsorbed explosive particulates under real-world conditions with a useful degree of reliability.

  3. Nucleic acid encoding a self-assembling split-fluorescent protein system

    DOE Patents [OSTI]

    Waldo, Geoffrey S.; Cabantous, Stephanie

    2015-07-14

    The invention provides a protein labeling and detection system based on self-complementing fragments of fluorescent and chromophoric proteins. The system of the invention is exemplified with various combinations of self-complementing fragments derived from Aequorea victoria Green Fluorescent Protein (GFP), which are used to detect and quantify protein solubility in multiple assay formats, both in vitro and in vivo.

  4. Nucleic acid encoding a self-assembling split-fluorescent protein system

    DOE Patents [OSTI]

    Waldo, Geoffrey S; Cabantous, Stephanie

    2014-04-01

    The invention provides a protein labeling and detection system based on self-complementing fragments of fluorescent and chromophoric proteins. The system of the invention is exemplified with various combinations of self-complementing fragments derived from Aequorea victoria Green Fluorescent Protein (GFP), which are used to detect and quantify protein solubility in multiple assay formats, both in vitro and in vivo.

  5. Means and method for capillary zone electrophoresis with laser-induced indirect fluorescence detection

    DOE Patents [OSTI]

    Yeung, Edward S.; Kuhr, Werner G.

    1996-02-20

    A means and method for capillary zone electrphoresis with laser-induced indirect fluorescence detection. A detector is positioned on the capillary tube of a capillary zone electrophoresis system. The detector includes a laser which generates a laser beam which is imposed upon a small portion of the capillary tube. Fluorescence of the elutant electromigrating through the capillary tube is indirectly detected and recorded.

  6. Means and method for capillary zone electrophoresis with laser-induced indirect fluorescence detection

    DOE Patents [OSTI]

    Yeung, Edwards; Kuhr, Werner G.

    1991-04-09

    A means and method for capillary zone electrphoresis with laser-induced indirect fluorescence detection. A detector is positioned on the capillary tube of a capillary zone electrophoresis system. The detector includes a laser which generates a laser beam which is imposed upon a small portion of the capillary tube. Fluorescence of the elutant electromigrating through the capillary tube is indirectly detected and recorded.

  7. Nucleic acid encoding a self-assembling split-fluorescent protein system

    DOE Patents [OSTI]

    Waldo, Geoffrey S.; Cabantous, Stephanie

    2011-06-07

    The invention provides a protein labeling and detection system based on self-complementing fragments of fluorescent and chromophoric proteins. The system of the invention is exemplified with various combinations of self-complementing fragments derived from Aequorea victoria Green Fluorescent Protein (GFP), which are used to detect and quantify protein solubility in multiple assay formats, both in vitro and in vivo.

  8. Directed evolution methods for improving polypeptide folding and solubility and superfolder fluorescent proteins generated thereby

    DOE Patents [OSTI]

    Waldo, Geoffrey S.

    2007-09-18

    The current invention provides methods of improving folding of polypeptides using a poorly folding domain as a component of a fusion protein comprising the poorly folding domain and a polypeptide of interest to be improved. The invention also provides novel green fluorescent proteins (GFPs) and red fluorescent proteins that have enhanced folding properties.

  9. Mapping protein collapse with single molecule fluorescence and...

    Office of Scientific and Technical Information (OSTI)

    Resource Type: Journal Article Resource Relation: Journal Name: Proceedings of the National Academy of Sciences of the United States of America, na, na, December 21, 2006, pp. 105 ...

  10. X-ray optics for scanning fluorescence microscopy and other applications

    SciTech Connect (OSTI)

    Ryon, R.W.; Warburton, W.K.

    1992-05-01

    Scanning x-ray fluorescence microscopy is analogous to scanning electron microscopy. Maps of chemical element distribution are produced by scanning with a very small x-ray beam. Goal is to perform such scanning microscopy with resolution in the range of <1 to 10 {mu}m, using standard laboratory x-ray tubes. We are investigating mirror optics in the Kirkpatrick-Baez (K-B) configuration. K-B optics uses two curved mirrors mounted orthogonally along the optical axis. The first mirror provides vertical focus, the second mirror provides horizontal focus. We have used two types of mirrors: synthetic multilayers and crystals. Multilayer mirrors are used with lower energy radiation such as Cu K{alpha}. At higher energies such as Ag K{alpha}, silicon wafers are used in order to increase the incidence angles and thereby the photon collection efficiency. In order to increase the surface area of multilayers which reflects x-rays at the Bragg angle, we have designed mirrors with the spacing between layers graded along the optic axis in order to compensate for the changing angle of incidence. Likewise, to achieve a large reflecting surface with silicon, the wafers are placed on a specially designed lever arm which is bent into a log spiral by applying force at one end. In this way, the same diffracting angle is maintained over the entire surface of the wafer, providing a large solid angle for photon collection.

  11. DOE Requires Manufacturer and Labeler to Cease Sale of Incandescent Reflector Lamps

    Broader source: Energy.gov [DOE]

    DOE has issued Notices of Non-Compliance Determination to Westinghouse Lighting Corporation and Fuzhou Sunlight Lighting Electrical Appliance Company requiring that they halt the sale of 8 basic...

  12. CALiPER Benchmark Report: Performance of Halogen Incandescent MR16 Lamps and LED Replacement

    SciTech Connect (OSTI)

    Paget, M. L.; Lingard, R. D.; Myer, M. A.

    2008-11-01

    This benchmark report addresses the halogen MR16 lamp and its commercially available light-emitting diode (LED) replacements.

  13. Laser-induced incandescence: Particulate diagnostics for combustion, atmospheric, and industrial applications

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Michelsen, H. A.; Schulz, C.; Smallwood, G. J.; Will, S.

    2015-09-09

    The understanding of soot formation in combustion processes and the optimization of practical combustion systems require in situ measurement techniques that can provide important characteristics, such as particle concentrations and sizes, under a variety of conditions. Of equal importance are techniques suitable for characterizing soot particles produced from incomplete combustion and emitted into the environment. Also, the production of engineered nanoparticles, such as carbon blacks, may benefit from techniques that allow for online monitoring of these processes.

  14. Aerosol Mass Spectrometry via Laser-Induced Incandescence Particle Vaporization Final Report

    SciTech Connect (OSTI)

    Timothy B. Onasch

    2011-10-20

    We have successfully developed and commercialized a soot particle aerosol mass spectrometer (SP-AMS) instrument to measure mass, size, and chemical information of soot particles in ambient environments. The SP-AMS instrument has been calibrated and extensively tested in the laboratory and during initial field studies. The first instrument paper describing the SP-AMS has been submitted for publication in a peer reviewed journal and there are several related papers covering initial field studies and laboratory studies that are in preparation. We have currently sold 5 SP-AMS instruments (either as complete systems or as SP modules to existing AMS instrument operators).

  15. Laser-induced incandescence: Particulate diagnostics for combustion, atmospheric, and industrial applications

    SciTech Connect (OSTI)

    Michelsen, H. A.; Schulz, C.; Smallwood, G. J.; Will, S.

    2015-09-09

    The understanding of soot formation in combustion processes and the optimization of practical combustion systems require in situ measurement techniques that can provide important characteristics, such as particle concentrations and sizes, under a variety of conditions. Of equal importance are techniques suitable for characterizing soot particles produced from incomplete combustion and emitted into the environment. Also, the production of engineered nanoparticles, such as carbon blacks, may benefit from techniques that allow for online monitoring of these processes.

  16. Cyanine-based probe\\tag-peptide pair for fluorescence protein imaging and fluorescence protein imaging methods

    DOE Patents [OSTI]

    Mayer-Cumblidge, M. Uljana; Cao, Haishi

    2010-08-17

    A molecular probe comprises two arsenic atoms and at least one cyanine based moiety. A method of producing a molecular probe includes providing a molecule having a first formula, treating the molecule with HgOAc, and subsequently transmetallizing with AsCl.sub.3. The As is liganded to ethanedithiol to produce a probe having a second formula. A method of labeling a peptide includes providing a peptide comprising a tag sequence and contacting the peptide with a biarsenical molecular probe. A complex is formed comprising the tag sequence and the molecular probe. A method of studying a peptide includes providing a mixture containing a peptide comprising a peptide tag sequence, adding a biarsenical probe to the mixture, and monitoring the fluorescence of the mixture.

  17. CALiPER Benchmark Report: Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps

    SciTech Connect (OSTI)

    Myer, M. A.; Paget, M. L.; Lingard, R. D.

    2009-01-01

    This report examines standard fluorescent lamps, the recessed troffers they are commonly used in, and available LED replacements for T12 and T8 fluorescent lamps and their application in fluorescent troffers.

  18. Another Side of Light - D

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    D. Three quantum phenomena In fluorescence, matter absorbs light waves of a high frequency and then emits light of the same or lower frequency. This process was studied and named by George Gabriel Stokes in the mid-19th century. Today, fluorescence is familiar to us from fluorescent light bulbs. A fluorescent bulb's filament produces ultraviolet light, which is absorbed by the bulb's inner coating, which then emits lower-frequency visible light-more visible light than an incandescent bulb

  19. Raman scattering and red fluorescence in the photochemical transformation of dry tryptophan particles

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Lai, Chih Wei; Schwab, Mark; Hill, Steven C.; Santarpia, Joshua; Pan, Yong -Le

    2016-05-19

    Tryptophan is a fluorescent amino acid common in proteins. Its absorption is largest for wavelengths λ ≲ 290 nm and its fluorescence emissions peak around 300–350 nm, depending upon the local environment. Here we report the observation of red fluorescence near 600 nm emerging from 488-nm continuous-wave (CW) laser photoexcitation of dry tryptophan (Trp) particles. With an excitation intensity below 0.5 kW/cm2, dry Trp particles yield distinctive Raman scattering peaks in the presence of relatively weak and spectrally broad emissions with λ ~500–700 nm, allowing estimation of particle temperature at low excitation intensities. When the photoexcitation intensity is increased tomore » 1 kW/cm2 or more for a few minutes, fluorescence intensity dramatically increases by more than two orders of magnitude. The fluorescence continues to increase in intensity and gradually shift to the red when photoexcitation intensity and the duration of exposure are increased. The resulting products absorb at visible wavelengths and generate red fluorescence with λ ~ 650–800 nm with 633-nm CW laser excitation. In conclusion, we attribute the emergence of orange and red fluorescence in the Trp products to a photochemical transformation that is instigated by weak optical transitions to triplet states in Trp with 488-nm excitation and which may be expedited by a photothermal effect.« less

  20. Total internal reflection fluorescence spectrometer to study dynamic adsorption phenomena at liquid/liquid interfaces

    SciTech Connect (OSTI)

    Tupy, M.J.; Blanch, H.W.; Radke, C.J.

    1998-08-01

    Adsorption at oil/water interfaces affects the performance of many industrial systems including oil recovery, extraction processes, cosmetic products, and food technology. However, no technique currently available can monitor adsorption dynamics using molecularly sensitive methods. The authors have constructed a novel total internal reflection fluorescence spectrometer (TIRFS) to follow dynamic adsorption events at the oil/water interface. The TIRFS monitors changes in fluorescence intensity and fluorescence spectra over time by maintaining an optical focus on the fluid interface during adsorption and desorption processes. Kinetic adsorption phenomena are examined by altering the composition of the aqueous phase and recording surface fluorescence response without mechanically disturbing the fluid/fluid interface. The spectrometer captures changes in the fluorescence intensity over tenths of seconds and maintains optical focus for periods of days. Mass transport of fluorescing surface-active material to and from the oil/water interface is accurately modeled using the simple one-dimensional diffusion equation. The geometry designed for this apparatus can be applied to other light-based techniques studying adsorption at liquid/liquid interfaces. Here, the authors apply the TIRFS apparatus to the study of {beta}-casein adsorption and desorption at an aliphatic oil/water interface. The observed increase in interfacial fluorescence due to {beta}-casein adsorption is slower than the diffusive flux, and desorption is found to be very slow if not irreversible. The TIRF spectrum indicates interaction of sorbed {beta}-casein with the oil phase and subsequent rearrangement of the native structure.

  1. Buildings Energy Data Book: 5.6 Lighting

    Buildings Energy Data Book [EERE]

    Residential Commercial Industrial Other (2) Total Incandescent 1640 49% 180 1% 0 0% 50 1% 1870 5% General (A-type, Decorative) 1390 42% 120 0% 0 0% - - 1510 4% Reflector 190 6% 60 ...

  2. Fluorescence Correlation Spectroscopy at Micromolar Concentrations without Optical Nanoconfinement

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Laurence, Ted A.; Ly, Sonny; Bourguet, Feliza; Fischer, Nicholas O.; Coleman, Matthew A.

    2014-08-14

    Fluorescence correlation spectroscopy (FCS) is an important technique for studying biochemical interactions dynamically that may be used in vitro and in cell-based studies. It is generally claimed that FCS may only be used at nM concentrations. We show that this general consensus is incorrect and that the limitation to nM concentrations is not fundamental but due to detector limits as well as laser fluctuations. With a high count rate detector system and applying laser fluctuation corrections, we demonstrate FCS measurements up to 38 μM with the same signal-to-noise as at lower concentrations. Optical nanoconfinement approaches previously used to increase themore » concentration range of FCS are not necessary, and further increases above 38 μM may be expected using detectors and detector arrays with higher saturation rates and better laser fluctuation corrections. This approach greatly widens the possibilities of dynamic measurements of biochemical interactions using FCS at physiological concentrations.« less

  3. Continuous Flow Cryostat for X-Ray Fluorescence

    SciTech Connect (OSTI)

    Weng, T.-C.; Linden, Peter J. E. M. van der; Glatzel, Pieter; Lapras, Christophe; Krzyzowski, Michael

    2010-06-23

    A continuous Helium flow cryostat was designed and built by Cryovac GMbH to specifications given by ESRF beamline ID26. The beamline has constructed a high energy resolution X-ray emission spectrometer using multiple spherically bent analyser crystals, together with the sample and detector on a vertical Rowland circle. The double shrouded cryostat has a low profile designed to fit into the spectrometer setup, the lowest detector position allows for a Bragg angle of 85 degrees with a 1 meter diameter Rowland circle. The cryostat has a temperature range of 5 to 300 Kelvin on the sample holder which is cooled by static Helium exchange gas. The cryostat has triple windows for beam entrance, transmission and fluorescence; the latter offers an opening angle of 80 degrees horizontally and 50 degrees vertically. The cryostat can be configured to work in two different operation modes: translation or rotation. The translation mode offers a displacement of 50 mm to accommodate multiple samples on the sample holder. The rotation mode is used for polarisation studies on single crystals.We show recent results obtained on Chromium containing molecular complexes; data collection was done at a temperature of 10 Kelvin to avoid radiation damage.

  4. High sensitivity fluorescent single particle and single molecule detection apparatus and method

    DOE Patents [OSTI]

    Mathies, Richard A.; Peck, Konan; Stryer, Lubert

    1990-01-01

    Apparatus is described for ultrasensitive detection of single fluorescent particles down to the single fluorescent molecule limit in a fluid or on a substrate comprising means for illuminating a predetermined volume of the fluid or area of the substrate whereby to emit light including background light from the fluid and burst of photons from particles residing in the area. The photon burst is detected in real time to generate output representative signal. The signal is received and the burst of energy from the fluorescent particles is distinguished from the background energy to provide an indication of the number, location or concentration of the particles or molecules.

  5. On-site demonstration procedure for solid-state fluorescent ballast

    SciTech Connect (OSTI)

    Verderber, R.; Morse, O.

    1980-09-01

    The report was presented to plant engineers and managers who were involved in an on-site demonstration of EETech solid-state ballasts for two 40-watt T12 fluorescent lamps. The report includes a brief review of the operating principles of solid-state fluorescent ballasts and the status of development achieved during the LBL program. The remainder of the test describes the techniques of managing and instrumenting a test area for assessing the performance of solid-state fluorescent ballasts at an occupied site.

  6. Tornado type wind turbines

    DOE Patents [OSTI]

    Hsu, Cheng-Ting

    1984-01-01

    A tornado type wind turbine has a vertically disposed wind collecting tower with spaced apart inner and outer walls and a central bore. The upper end of the tower is open while the lower end of the structure is in communication with a wind intake chamber. An opening in the wind chamber is positioned over a turbine which is in driving communication with an electrical generator. An opening between the inner and outer walls at the lower end of the tower permits radially flowing air to enter the space between the inner and outer walls while a vertically disposed opening in the wind collecting tower permits tangentially flowing air to enter the central bore. A porous portion of the inner wall permits the radially flowing air to interact with the tangentially flowing air so as to create an intensified vortex flow which exits out of the top opening of the tower so as to create a low pressure core and thus draw air through the opening of the wind intake chamber so as to drive the turbine.

  7. Electric Power | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Power Electric Power From incandescent bulbs to fluorescents to LEDs, <a href="/node/772396">learn more</a> about the long history of the light bulb. From incandescent bulbs to fluorescents to LEDs, learn more about the long history of the light bulb. Electricity -- the flow of electrical power -- is a secondary energy source, generated by the conversion of primary sources of energy, like fossil, nuclear, wind or solar. Keeping the power flowing to American homes and

  8. Transition-Edge Sensor X-Ray Fluorescence (TES-XRF) for High...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    X-Ray Fluorescence (XRF) is a technique for material identification. A low energy electron gun bombards a thin foil anode to produce a spectrum of x-rays that irradiate a material ...

  9. Deterministically Polarized Fluorescence from Single Dye Molecules Aligned in Liquid Crystal Host

    SciTech Connect (OSTI)

    Lukishova, S.G.; Schmid, A.W.; Knox, R.; Freivald, P.; Boyd, R. W.; Stroud, Jr., C. R.; Marshall, K.L.

    2005-09-30

    We demonstrated for the first time to our konwledge deterministically polarized fluorescence from single dye molecules. Planar aligned nematic liquid crystal hosts provide deterministic alignment of single dye molecules in a preferred direction.

  10. Laser-induced fluorescence-cued, laser-induced breakdown spectroscopy biological-agent detection

    SciTech Connect (OSTI)

    Hybl, John D.; Tysk, Shane M.; Berry, Shaun R.; Jordan, Michael P

    2006-12-01

    Methods for accurately characterizing aerosols are required for detecting biological warfare agents. Currently, fluorescence-based biological agent sensors provide adequate detection sensitivity but suffer from high false-alarm rates. Combining single-particle fluorescence analysis with laser-induced breakdown spectroscopy (LIBS) provides additional discrimination and potentially reduces false-alarm rates. A transportable UV laser-induced fluorescence-cued LIBS test bed has been developed and used to evaluate the utility of LIBS for biological-agent detection. Analysis of these data indicates that LIBS adds discrimination capability to fluorescence-based biological-agent detectors.However, the data also show that LIBS signatures of biological agent simulants are affected by washing. This may limit the specificity of LIBS and narrow the scope of its applicability in biological-agent detection.

  11. Conservation potential of compact fluorescent lamps in India and Brazil

    SciTech Connect (OSTI)

    Gadgil, A.; Martino Jannuzzi, G. de (Lawrence Berkeley Lab., CA (USA); Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia)

    1989-07-01

    We evaluate the conservation potential of compact fluorescent lamps (CFLs) for managing the rapidly increasing electrical energy and peak demand in India and Brazil. Using very conservative assumptions, we find that the cost of conserved energy using 16 W CFLs is 4 and 6 times less than the long range marginal cost of electricity for the two countries. The cost of avoided peak installed capacity is 6 and 9.5 times less than the cost of new installed capacity for India and Brazil. The analysis is undertaken from the three separate perspectives of the national economies, the consumers, and the utilities. We find that because residential electricity is subsidized, the consumers have little or no incentive to purchase and install the CFLs, unless they too are subsidized. However, the benefits of CFL installation to the utility are so large that subsidizing them is a paying proposition for the utility are so large that subsidizing them is a paying proposition for the utility in almost all cases. As an illustration of a gradual introduction strategy for CFLs, we calculate a scenario where national savings of the order of US $1.2 million per day for India and US $2.5 million per day for Brazil are reached in 10 years by a small and gradual transfer of subsidy from residential electricity to CFLs. We then explore the barriers to immediate large scale introduction of these lamps in the two countries. Specific technical and marketing problems are identified and discussed, which would require solution before such an introduction can be attempted. Lastly, we discuss the range of policy instruments, in addition to a subsidy scheme, that can be used for promoting the diffusion of these lamps in the domestic and commercial sector. 47 refs., 15 figs., 2 tabs.

  12. Compact Fluorescent Lighting in America: Lessons Learned on the Way to

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Market | Department of Energy Compact Fluorescent Lighting in America: Lessons Learned on the Way to Market Compact Fluorescent Lighting in America: Lessons Learned on the Way to Market This report reviews efforts to increase market acceptance of CFLs and barriers to that acceptance. cfl_lessons_learned_web.pdf (922.25 KB) More Documents & Publications Consumer Light Bulb Changes: Briefing and Resources for Media and Retailers Life-Cycle Assessment of Energy and Environmental Impacts of

  13. On-line measurement of lignin in wood pulp by color shift of fluorescence

    SciTech Connect (OSTI)

    Jeffers, Larry A.; Malito, Michael L.

    1996-01-01

    Lignin concentrations from wood pulp samples are measured by applying an excitation light at a selected wavelength to the samples in order to cause the lignin to emit fluorescence. A spectral distribution of the fluorescence emission is then determined. The lignin concentration is then calculated based on the spectral distribution signal. The spectral distribution is quantified by either a wavelength centroid method or a band ratio method.

  14. On-line measurement of lignin in wood pulp by color shift of fluorescence

    DOE Patents [OSTI]

    Jeffers, L.A.; Malito, M.L.

    1996-01-23

    Lignin concentrations from wood pulp samples are measured by applying an excitation light at a selected wavelength to the samples in order to cause the lignin to emit fluorescence. A spectral distribution of the fluorescence emission is then determined. The lignin concentration is then calculated based on the spectral distribution signal. The spectral distribution is quantified by either a wavelength centroid method or a band ratio method. 6 figs.

  15. Enhanced multicolor fluorescence in bioimaging using deep-ultraviolet surface plasmon resonance

    SciTech Connect (OSTI)

    Kikawada, Masakazu; Ono, Atsushi; Inami, Wataru; Kawata, Yoshimasa

    2014-06-02

    Enhanced multicolor fluorescence has been achieved using deep-ultraviolet surface plasmon resonance (DUV-SPR) on an aluminum thin film using the Kretschmann configuration. The film thickness and the incident angle of the light were optimized by calculations using the Fresnel equations. The presence of a surface oxide layer was also considered in the calculations. Experimental measurements showed that DUV-SPR led to a strong enhancement of the fluorescence intensity from both quantum dots and dye-labeled cells.

  16. Flow method and apparatus for screening chemicals using micro x-ray fluorescence

    DOE Patents [OSTI]

    Warner, Benjamin P.; Havrilla, George J.; Miller, Thomasin C.; Lewis, Cris; Mahan, Cynthia A.; Wells, Cyndi A.

    2011-04-26

    Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.

  17. Flow method and apparatus for screening chemicals using micro x-ray fluorescence

    DOE Patents [OSTI]

    Warner, Benjamin P.; Havrilla, George J.; Miller, Thomasin C.; Lewis, Cris; Mahan, Cynthia A.; Wells, Cyndi A.

    2009-04-14

    Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow-separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.

  18. Use of Standard Fluorescent UV Weathering Lamps to Perform UV Conditioning

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Tests Prescribed in IEC Qualification Standards | Department of Energy Use of Standard Fluorescent UV Weathering Lamps to Perform UV Conditioning Tests Prescribed in IEC Qualification Standards Use of Standard Fluorescent UV Weathering Lamps to Perform UV Conditioning Tests Prescribed in IEC Qualification Standards Presented at the PV Module Reliability Workshop, February 26 - 27 2013, Golden, Colorado pvmrw13_ps5_qlab_fowler.pdf (691.74 KB) More Documents & Publications Weathering

  19. Organic light-emitting device with a phosphor-sensitized fluorescent emission layer

    DOE Patents [OSTI]

    Forrest, Stephen; Kanno, Hiroshi

    2009-08-25

    The present invention relates to organic light emitting devices (OLEDs), and more specifically to OLEDS that emit light using a combination of fluorescent emitters and phosphorescent emitters. The emissive region of the devices of the present invention comprise at least one phosphor-sensitized layer which has a combined emission from a phosphorescent emitter and a fluorescent emitter. In preferred embodiments, the invention relates to white-emitting OLEDS (WOLEDs).

  20. Solid-immersion fluorescence microscopy with increased emission and super resolution

    SciTech Connect (OSTI)

    Liau, Z. L.; Porter, J. M.; Liau, A. A.; Chen, J. J.; Salmon, W. C.; Sheu, S. S.

    2015-01-07

    We investigate solid-immersion fluorescence microscopy suitable for super-resolution nanotechnology and biological imaging, and have observed limit of resolution as small as 15?nm with microspheres, mitochondria, and chromatin fibers. We have further observed that fluorescence efficiency increases with excitation power density, implicating appreciable stimulated emission and increased resolution. We discuss potential advantages of the solid-immersion microscopy, including combined use with previously established super-resolution techniques for reaching deeper beyond the conventional diffraction limit.

  1. Uranium(VI) coordination polymers with pyromellitate ligand: Unique 1D channel structures and diverse fluorescence

    SciTech Connect (OSTI)

    Zhang, Yingjie; Bhadbhade, Mohan; Karatchevtseva, Inna; Price, Jason R.; Liu, Hao; Zhang, Zhaoming; Kong, Linggen; Čejka, Jiří; Lu, Kim; Lumpkin, Gregory R.

    2015-03-15

    Three new coordination polymers of uranium(VI) with pyromellitic acid (H{sub 4}btca) have been synthesized and structurally characterized. (ED)[(UO{sub 2})(btca)]·(DMSO)·3H{sub 2}O (1) (ED=ethylenediammonium; DMSO=dimethylsulfoxide) has a lamellar structure with intercalation of ED and DMSO. (NH{sub 4}){sub 2}[(UO{sub 2}){sub 6}O{sub 2}(OH){sub 6}(btca)]·~6H{sub 2}O (2) has a 3D framework built from 7-fold coordinated uranyl trinuclear units and btca ligands with 1D diamond-shaped channels (~8.5 Å×~8.6 Å). [(UO{sub 2}){sub 2}(H{sub 2}O)(btca)]·4H{sub 2}O (3) has a 3D network constructed by two types of 7-fold coordinated uranium polyhedron. The unique μ{sub 5}-coordination mode of btca in 3 enables the formation of 1D olive-shaped large channels (~4.5 Å×~19 Å). Vibrational modes, thermal stabilities and fluorescence properties have been investigated. - Graphical abstract: Table of content: three new uranium(VI) coordination polymers with pyromellitic acid (H{sub 4}btca) have been synthesized via room temperature and hydrothermal synthesis methods, and structurally characterized. Two to three dimensional (3D) frameworks are revealed. All 3D frameworks have unique 1D large channels. Their vibrational modes, thermal stabilities and photoluminescence properties have been investigated. - Highlights: • Three new coordination polymers of U(VI) with pyromellitic acid (H{sub 4}btca). • Structures from a 2D layer to 3D frameworks with unique 1D channels. • Unusual µ{sub 5}-(η{sub 1}:η{sub 2}:η{sub 1}:η{sub 2:}η{sub 1}) coordination mode of btca ligand. • Vibrational modes, thermal stabilities and luminescent properties reported.

  2. Window Types | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Window Types Window Types A wood-frame window with insulated window glazing. | Photo courtesy of ©iStockphoto/chandlerphoto A wood-frame window with insulated window glazing. | Photo courtesy of ©iStockphoto/chandlerphoto Windows come in a number of different frame and glazing types. By combining an energy-efficient frame choice with a glazing type tailored to your climate and application, you can customize each of your home's windows. Types of Window Frames Improving the thermal resistance

  3. Feasibility of x ray fluorescence for spent fuel safeguards

    SciTech Connect (OSTI)

    Freeman, Corey Ross; Mozin, Vladimir; Tobin, Stephen J; Fensin, Michael L; White, Julia M; Croft, Stephen; Stafford, Alissa; Charlton, William

    2010-01-01

    Quantifying the Pu content in spent nuclear fuel is necessary for many reasons, in particular to verify that diversion or other illicit activities have not occurred. Therefore, safeguarding the world's nuclear fuel is paramount to responsible nuclear regulation and public acceptance, but achieving this goal presents many difficulties from both a technical and economic perspective. The Next Generation Safeguards Initiative (NGSI) of NA-24 is funding a large collaborative effort between multiple laboratories and universities to improve spent nuclear fuel safeguards methods and equipment. This effort involves the current work of modeling several different nondestructive assay (NDA) techniques. Several are being researched, because no single NDA technique, in isolation, has the potential to properly characterize fuel assemblies and offer a robust safeguards measure. The insights gained from this research, will be used to down-select from the original set a few of the most promising techniques that complement each other. The goal is to integrate the selected instruments to create an accurate measurement system for fuel verification that is also robust enough to detect diversions. These instruments will be fabricated and tested under realistic conditions. This work examines one of the NDA techniques; the feasibility of using x ray emission peaks from Pu and U to gather information about their relative quantities in the spent fuel. X Ray Fluorescence (XRF), is unique compared to the investigated techniques in that it is the only one able to give the elemental ratio of Pu to U, allowing the possibility of a Pu gram quantity for the assembly to be calculated. XRF also presents many challenges, mainly its low penetration, since the low energy x rays of interest are effectively shielded by the first few millimeters of a fuel pin. This paper will explore the results of Monte Carlo N-Particle eXtended (MCNPX) transport code calculations of spent fuel x ray peaks. The MCNPX

  4. Zero energy-storage ballast for compact fluorescent lamps

    DOE Patents [OSTI]

    Schultz, William Newell; Thomas, Robert James

    1999-01-01

    A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast.

  5. DIORAMA Location Type User's Guide

    SciTech Connect (OSTI)

    Terry, James Russell

    2015-01-29

    The purpose of this report is to present the current design and implementation of the DIORAMA location type object (LocationType) and to provide examples and use cases. The LocationType object is included in the diorama-app package in the diorama::types namespace. Abstractly, the object is intended to capture the full time history of the location of an object or reference point. For example, a location may be speci ed as a near-Earth orbit in terms of a two-line element set, in which case the location type is capable of propagating the orbit both forward and backward in time to provide a location for any given time. Alternatively, the location may be speci ed as a xed set of geodetic coordinates (latitude, longitude, and altitude), in which case the geodetic location of the object is expected to remain constant for all time. From an implementation perspective, the location type is de ned as a union of multiple independent objects defi ned in the DIORAMA tle library. Types presently included in the union are listed and described in subsections below, and all conversions or transformation between these location types are handled by utilities provided by the tle library with the exception of the \\special-values" location type.

  6. Window Types | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    its U-factor. There are advantages and disadvantages to all types of frame materials, but vinyl, wood, fiberglass, and some composite frame materials provide greater...

  7. Characterization of energy response for photon-counting detectors using x-ray fluorescence

    SciTech Connect (OSTI)

    Ding, Huanjun; Cho, Hyo-Min; Molloi, Sabee; Barber, William C.; Iwanczyk, Jan S.

    2014-12-15

    Purpose: To investigate the feasibility of characterizing a Si strip photon-counting detector using x-ray fluorescence. Methods: X-ray fluorescence was generated by using a pencil beam from a tungsten anode x-ray tube with 2 mm Al filtration. Spectra were acquired at 90 from the primary beam direction with an energy-resolved photon-counting detector based on an edge illuminated Si strip detector. The distances from the source to target and the target to detector were approximately 19 and 11 cm, respectively. Four different materials, containing silver (Ag), iodine (I), barium (Ba), and gadolinium (Gd), were placed in small plastic containers with a diameter of approximately 0.7 cm for x-ray fluorescence measurements. Linear regression analysis was performed to derive the gain and offset values for the correlation between the measured fluorescence peak center and the known fluorescence energies. The energy resolutions and charge-sharing fractions were also obtained from analytical fittings of the recorded fluorescence spectra. An analytical model, which employed four parameters that can be determined from the fluorescence calibration, was used to estimate the detector response function. Results: Strong fluorescence signals of all four target materials were recorded with the investigated geometry for the Si strip detector. The average gain and offset of all pixels for detector energy calibration were determined to be 6.95 mV/keV and ?66.33 mV, respectively. The detectors energy resolution remained at approximately 2.7 keV for low energies, and increased slightly at 45 keV. The average charge-sharing fraction was estimated to be 36% within the investigated energy range of 2045 keV. The simulated detector output based on the proposed response function agreed well with the experimental measurement. Conclusions: The performance of a spectral imaging system using energy-resolved photon-counting detectors is very dependent on the energy calibration of the detector. The

  8. Fluorescence enhancement in large-scale self-assembled gold nanoparticle double arrays

    SciTech Connect (OSTI)

    Chekini, M.; Bierwagen, J.; Cunningham, A.; Bürgi, T.; Filter, R.; Rockstuhl, C.

    2015-12-21

    Localized surface plasmon resonances excited in metallic nanoparticles confine and enhance electromagnetic fields at the nanoscale. This is particularly pronounced in dimers made from two closely spaced nanoparticles. When quantum emitters, such as dyes, are placed in the gap of those dimers, their absorption and emission characteristics can be modified. Both processes have to be considered when aiming to enhance the fluorescence from the quantum emitters. This is particularly challenging for dimers, since the electromagnetic properties and the enhanced fluorescence sensitively depend on the distance between the nanoparticles. Here, we use a layer-by-layer method to precisely control the distances in such systems. We consider a dye layer deposited on top of an array of gold nanoparticles or integrated into a central position of a double array of gold nanoparticles. We study the effect of the spatial arrangement and the average distance on the plasmon-enhanced fluorescence. We found a maximum of a 99-fold increase in the fluorescence intensity of the dye layer sandwiched between two gold nanoparticle arrays. The interaction of the dye layer with the plasmonic system also causes a spectral shift in the emission wavelengths and a shortening of the fluorescence life times. Our work paves the way for large-scale, high throughput, and low-cost self-assembled functionalized plasmonic systems that can be used as efficient light sources.

  9. Method for detecting point mutations in DNA utilizing fluorescence energy transfer

    DOE Patents [OSTI]

    Parkhurst, Lawrence J.; Parkhurst, Kay M.; Middendorf, Lyle

    2001-01-01

    A method for detecting point mutations in DNA using a fluorescently labeled oligomeric probe and Forster resonance energy transfer (FRET) is disclosed. The selected probe is initially labeled at each end with a fluorescence dye, which act together as a donor/acceptor pair for FRET. The fluorescence emission from the dyes changes dramatically from the duplex stage, wherein the probe is hybridized to the complementary strand of DNA, to the single strand stage, when the probe is melted to become detached from the DNA. The change in fluorescence is caused by the dyes coming into closer proximity after melting occurs and the probe becomes detached from the DNA strand. The change in fluorescence emission as a function of temperature is used to calculate the melting temperature of the complex or T.sub.m. In the case where there is a base mismatch between the probe and the DNA strand, indicating a point mutation, the T.sub.m has been found to be significantly lower than the T.sub.m for a perfectly match probelstand duplex. The present invention allows for the detection of the existence and magnitude of T.sub.m, which allows for the quick and accurate detection of a point mutation in the DNA strand and, in some applications, the determination of the approximate location of the mutation within the sequence.

  10. A fluorescence-based method for rapid and direct determination of polybrominated diphenyl ethers in water

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Shan, Huimei; Liu, Chongxuan; Wang, Zheming; Ma, Teng; Shang, Jianying; Pan, Duoqiang

    2015-01-01

    A new method was developed for rapid and direct measurement of polybrominated diphenyl ethers (PBDEs) in aqueous samples using fluorescence spectroscopy. The fluorescence spectra of tri- to deca-BDE (BDE 28, 47, 99, 153, 190, and 209) commonly found in environment were measured at variable emission and excitation wavelengths. The results revealed that the PBDEs have distinct fluorescence spectral profiles and peak positions that can be exploited to identify these species and determine their concentrations in aqueous solutions. The detection limits as determined in deionized water spiked with PBDEs are 1.71-5.82 ng/L for BDE 28, BDE 47, BDE 190, and BDEmore » 209 and 45.55–69.95 ng/L for BDE 99 and BDE 153. The effects of environmental variables including pH, humic substance, and groundwater chemical composition on PBDEs measurements were also investigated. These environmental variables affected fluorescence intensity, but their effect can be corrected through linear additivity and separation of spectral signal contribution. Compared with conventional GC-based analytical methods, the fluorescence spectroscopy method is more efficient as it only uses a small amount of samples (2-4 mL), avoids lengthy complicated concentration and extraction steps, and has a low detection limit of a few ng/L.« less

  11. A fluorescence-based method for rapid and direct determination of polybrominated diphenyl ethers in water

    SciTech Connect (OSTI)

    Shan, Huimei; Liu, Chongxuan; Wang, Zheming; Ma, Teng; Shang, Jianying; Pan, Duoqiang

    2015-01-01

    A new method was developed for rapid and direct measurement of polybrominated diphenyl ethers (PBDEs) in aqueous samples using fluorescence spectroscopy. The fluorescence spectra of tri- to deca-BDE (BDE 28, 47, 99, 153, 190, and 209) commonly found in environment were measured at variable emission and excitation wavelengths. The results revealed that the PBDEs have distinct fluorescence spectral profiles and peak positions that can be exploited to identify these species and determine their concentrations in aqueous solutions. The detection limits as determined in deionized water spiked with PBDEs are 1.71-5.82 ng/L for BDE 28, BDE 47, BDE 190, and BDE 209 and 45.5569.95 ng/L for BDE 99 and BDE 153. The effects of environmental variables including pH, humic substance, and groundwater chemical composition on PBDEs measurements were also investigated. These environmental variables affected fluorescence intensity, but their effect can be corrected through linear additivity and separation of spectral signal contribution. Compared with conventional GC-based analytical methods, the fluorescence spectroscopy method is more efficient as it only uses a small amount of samples (2-4 mL), avoids lengthy complicated concentration and extraction steps, and has a low detection limit of a few ng/L.

  12. Archived Reference Building Type: Hospital

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  13. Archived Reference Building Type: Hospital

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  14. Archived Reference Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  15. Archived Reference Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  16. Archived Reference Building Type: Supermarket

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  17. Fluorescent and cathodoluminescent phophors structurally related to sodalite

    DOE Patents [OSTI]

    Phillips, Mark L. F.; Shea, Lauren E.

    1998-01-01

    Blue, quantum-confined phosphors for field-emission displays made by reducing metal (M) sulfoaluminates at high temperature. This yields phases of the type M.sub.4 (AlO.sub.2).sub.6 S. Bulk sulfide contaminant mixed with the reduced sulfoaluminate phase is removed by treating it with a chelating agent in nonaqueous solution. A photometric cathodoluminescence efficiency of 9 lumen/watt at 1000 V for Sr.sub.3 PbS(AlO.sub.2).sub.6 is observed. Undoped Sr.sub.4 S(AlO).sub.6 displays 5 lumen/watt at 1000 V, with excellent blue chromatic saturation.

  18. Zero energy-storage ballast for compact fluorescent lamps

    DOE Patents [OSTI]

    Schultz, W.N.; Thomas, R.J.

    1999-08-31

    A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast. 4 figs.

  19. Quantitative measurement of binary liquid distributions using multiple-tracer x-ray fluorescence and radiography

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Halls, Benjamin R.; Meyer, Terrence R.; Kastengren, Alan L.

    2015-01-23

    The complex geometry and large index-of-refraction gradients that occur near the point of impingement of binary liquid jets present a challenging environment for optical interrogation. A simultaneous quadruple-tracer x-ray fluorescence and line-of-sight radiography technique is proposed as a means of distinguishing and quantifying individual liquid component distributions prior to, during, and after jet impact. Two different pairs of fluorescence tracers are seeded into each liquid stream to maximize their attenuation ratio for reabsorption correction and differentiation of the two fluids during mixing. This approach for instantaneous correction of x-ray fluorescence reabsorption is compared with a more time-intensive approach of usingmorestereographic reconstruction of x-ray attenuation along multiple lines of sight. The proposed methodology addresses the need for a quantitative measurement technique capable of interrogating optically complex, near-field liquid distributions in many mixing systems of practical interest involving two or more liquid streams.less

  20. Average M shell fluorescence yields for elements with 70≤Z≤92

    SciTech Connect (OSTI)

    Kahoul, A.; Deghfel, B.; Aylikci, V.; Aylikci, N. K.; Nekkab, M.

    2015-03-30

    The theoretical, experimental and analytical methods for the calculation of average M-shell fluorescence yield (ω{sup ¯}{sub M}) of different elements are very important because of the large number of their applications in various areas of physical chemistry and medical research. In this paper, the bulk of the average M-shell fluorescence yield measurements reported in the literature, covering the period 1955 to 2005 are interpolated by using an analytical function to deduce the empirical average M-shell fluorescence yield in the atomic range of 70≤Z≤92. The results were compared with the theoretical and fitted values reported by other authors. Reasonable agreement was typically obtained between our result and other works.

  1. Hyper-filter-fluorescer spectrometer for x-rays above 120 keV

    DOE Patents [OSTI]

    Wang, Ching L.

    1983-01-01

    An apparatus utilizing filter-fluorescer combinations is provided to measure short bursts of high fluence x-rays above 120 keV energy, where there are no practical absorption edges available for conventional filter-fluorescer techniques. The absorption edge of the prefilter is chosen to be less than that of the fluorescer, i.e., E.sub.PRF E.sub.F. In this way, the response function is virtually zero between E.sub.PRF and E.sub.F and well defined and enhanced in an energy band of less than 1000 keV above the 120 keV energy.

  2. Quantitative measurement of binary liquid distributions using multiple-tracer x-ray fluorescence and radiography

    SciTech Connect (OSTI)

    Halls, Benjamin R.; Meyer, Terrence R.; Kastengren, Alan L.

    2015-01-01

    The complex geometry and large index-of-refraction gradients that occur near the point of impingement of binary liquid jets present a challenging environment for optical interrogation. A simultaneous quadruple-tracer x-ray fluorescence and line-of-sight radiography technique is proposed as a means of distinguishing and quantifying individual liquid component distributions prior to, during, and after jet impact. Two different pairs of fluorescence tracers are seeded into each liquid stream to maximize their attenuation ratio for reabsorption correction and differentiation of the two fluids during mixing. This approach for instantaneous correction of x-ray fluorescence reabsorption is compared with a more time-intensive approach of using stereographic reconstruction of x-ray attenuation along multiple lines of sight. The proposed methodology addresses the need for a quantitative measurement technique capable of interrogating optically complex, near-field liquid distributions in many mixing systems of practical interest involving two or more liquid streams.

  3. Demonstration of x-ray fluorescence imaging of a high-energy-density plasma

    SciTech Connect (OSTI)

    MacDonald, M. J. Gamboa, E. J.; Keiter, P. A.; Fein, J. R.; Klein, S. R.; Kuranz, C. C.; LeFevre, H. J.; Manuel, M. J.-E.; Wan, W. C.; Drake, R. P.; Montgomery, D. S.; Biener, M. M.; Fournier, K. B.; Streit, J.

    2014-11-15

    Experiments at the Trident Laser Facility have successfully demonstrated the use of x-ray fluorescence imaging (XRFI) to diagnose shocked carbonized resorcinol formaldehyde (CRF) foams doped with Ti. One laser beam created a shock wave in the doped foam. A second laser beam produced a flux of vanadium He-α x-rays, which in turn induced Ti K-shell fluorescence within the foam. Spectrally resolved 1D imaging of the x-ray fluorescence provided shock location and compression measurements. Additionally, experiments using a collimator demonstrated that one can probe specific regions within a target. These results show that XRFI is a capable alternative to path-integrated measurements for diagnosing hydrodynamic experiments at high energy density.

  4. Fluorescence measurements for evaluating the application of multivariate analysis techniques to optically thick environments.

    SciTech Connect (OSTI)

    Reichardt, Thomas A.; Timlin, Jerilyn Ann; Jones, Howland D. T.; Sickafoose, Shane M.; Schmitt, Randal L.

    2010-09-01

    Laser-induced fluorescence measurements of cuvette-contained laser dye mixtures are made for evaluation of multivariate analysis techniques to optically thick environments. Nine mixtures of Coumarin 500 and Rhodamine 610 are analyzed, as well as the pure dyes. For each sample, the cuvette is positioned on a two-axis translation stage to allow the interrogation at different spatial locations, allowing the examination of both primary (absorption of the laser light) and secondary (absorption of the fluorescence) inner filter effects. In addition to these expected inner filter effects, we find evidence that a portion of the absorbed fluorescence is re-emitted. A total of 688 spectra are acquired for the evaluation of multivariate analysis approaches to account for nonlinear effects.

  5. Facile method to stain the bacterial cell surface for super-resolution fluorescence microscopy

    SciTech Connect (OSTI)

    Gunsolus, Ian L.; Hu, Dehong; Mihai, Cosmin; Lohse, Samuel E.; Lee, Chang-Soo; Torelli, Marco; Hamers, Robert J.; Murphy, Catherine; Orr, Galya; Haynes, Christy L.

    2014-01-01

    A method to fluorescently stain the surfaces of both Gram-negative and Gram-positive bacterial cells compatible with super-resolution fluorescence microscopy is presented. This method utilizes a commercially-available fluorescent probe to label primary amines at the surface of the cell. We demonstrate efficient staining of two bacterial strains, the Gram-negative Shewanella oneidensis MR-1 and the Gram-positive Bacillus subtilis 168. Using structured illumination microscopy and stochastic optical reconstruction microscopy, which require high quantum yield or specialized dyes, we show that this staining method may be used to resolve the bacterial cell surface with sub-diffraction-limited resolution. We further use this method to identify localization patterns of nanomaterials, specifically cadmium selenide quantum dots, following interaction with bacterial cells.

  6. P-type gallium nitride

    DOE Patents [OSTI]

    Rubin, Michael; Newman, Nathan; Fu, Tracy; Ross, Jennifer; Chan, James

    1997-01-01

    Several methods have been found to make p-type gallium nitride. P-type gallium nitride has long been sought for electronic devices. N-type gallium nitride is readily available. Discovery of p-type gallium nitride and the methods for making it will enable its use in ultraviolet and blue light-emitting diodes and lasers. pGaN will further enable blue photocathode elements to be made. Molecular beam epitaxy on substrates held at the proper temperatures, assisted by a nitrogen beam of the proper energy produced several types of p-type GaN with hole concentrations of about 5.times.10.sup.11 /cm.sup.3 and hole mobilities of about 500 cm.sup.2 /V-sec, measured at 250.degree. K. P-type GaN can be formed of unintentionally-doped material or can be doped with magnesium by diffusion, ion implantation, or co-evaporation. When applicable, the nitrogen can be substituted with other group III elements such as Al.

  7. P-type gallium nitride

    DOE Patents [OSTI]

    Rubin, M.; Newman, N.; Fu, T.; Ross, J.; Chan, J.

    1997-08-12

    Several methods have been found to make p-type gallium nitride. P-type gallium nitride has long been sought for electronic devices. N-type gallium nitride is readily available. Discovery of p-type gallium nitride and the methods for making it will enable its use in ultraviolet and blue light-emitting diodes and lasers. pGaN will further enable blue photocathode elements to be made. Molecular beam epitaxy on substrates held at the proper temperatures, assisted by a nitrogen beam of the proper energy produced several types of p-type GaN with hole concentrations of about 5{times}10{sup 11} /cm{sup 3} and hole mobilities of about 500 cm{sup 2} /V-sec, measured at 250 K. P-type GaN can be formed of unintentionally-doped material or can be doped with magnesium by diffusion, ion implantation, or co-evaporation. When applicable, the nitrogen can be substituted with other group III elements such as Al. 9 figs.

  8. A portable time-domain LED fluorimeter for nanosecond fluorescence lifetime measurements

    SciTech Connect (OSTI)

    Wang, Hongtao; Salthouse, Christopher D.; Qi, Ying; Mountziaris, T. J.; Chemical Engineering Department, University of Massachusetts, Amherst, Massachusetts 01003

    2014-05-15

    Fluorescence lifetime measurements are becoming increasingly important in chemical and biological research. Time-domain lifetime measurements offer fluorescence multiplexing and improved handling of interferers compared with the frequency-domain technique. In this paper, an all solid-state, filterless, and highly portable light-emitting-diode based time-domain fluorimeter (LED TDF) is reported for the measurement of nanosecond fluorescence lifetimes. LED based excitation provides more wavelengths options compared to laser diode based excitation, but the excitation is less effective due to the uncollimated beam, less optical power, and longer latency in state transition. Pulse triggering and pre-bias techniques were implemented in our LED TDF to improve the peak optical power to over 100 mW. The proposed pulsing circuit achieved an excitation light fall time of less than 2 ns. Electrical resetting technique realized a time-gated photo-detector to remove the interference of the excitation light with fluorescence. These techniques allow the LED fluorimeter to accurately measure the fluorescence lifetime of fluorescein down to concentration of 0.5 μM. In addition, all filters required in traditional instruments are eliminated for the non-attenuated excitation/emission light power. These achievements make the reported device attractive to biochemical laboratories seeking for highly portable lifetime detection devices for developing sensors based on fluorescence lifetime changes. The device was initially validated by measuring the lifetimes of three commercial fluorophores and comparing them with reported lifetime data. It was subsequently used to characterize a ZnSe quantum dot based DNA sensor.

  9. Charge transfer fluorescence and 34 nm exciton diffusion length in polymers with electron acceptor end traps

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Zaikowski, Lori; Mauro, Gina; Bird, Matthew; Karten, Brianne; Asaoka, Sadayuki; Wu, Qin; Cook, Andrew R.; Miller, John R.

    2014-12-22

    Photoexcitation of conjugated poly-2,7-(9,9-dihexylfluorene) polyfluorenes with naphthylimide (NI) and anthraquinone (AQ) electron-acceptor end traps produces excitons that form charge transfer states at the end traps. Intramolecular singlet exciton transport to end traps was examined by steady state fluorescence for polyfluorenes of 17 to 127 repeat units in chloroform, dimethylformamide (DMF), tetrahydrofuran (THF), and p-xylene. End traps capture excitons and form charge transfer (CT) states at all polymer lengths and in all solvents. The CT nature of the end-trapped states is confirmed by their fluorescence spectra, solvent and trap group dependence and DFT descriptions. Quantum yields of CT fluorescence are asmore » large as 46%. This strong CT emission is understood in terms of intensity borrowing. Energies of the CT states from onsets of the fluorescence spectra give the depths of the traps which vary with solvent polarity. For NI end traps the trap depths are 0.06 (p-xylene), 0.13 (THF) and 0.19 eV (CHCl3). For AQ, CT fluorescence could be observed only in p-xylene where the trap depth is 0.27 eV. Quantum yields, emission energies, charge transfer energies, solvent reorganization and vibrational energies were calculated. Fluorescence measurements on chains >100 repeat units indicate that end traps capture ~50% of the excitons, and that the exciton diffusion length LD =34 nm, which is much larger than diffusion lengths reported in polymer films or than previously known for diffusion along isolated chains. As a result, the efficiency of exciton capture depends on chain length, but not on trap depth, solvent polarity or which trap group is present.« less

  10. Charge Transfer Fluorescence and 34 nm Exciton Diffusion Length in Polymers with Electron Acceptor End Traps

    SciTech Connect (OSTI)

    Zaikowski, L.; Mauro, G.; Bird, M.; Karten, B.; Asaoka, S.; Wu, Q.; Cook, A. R.; Miller, J.

    2014-12-22

    Photoexcitation of conjugated poly-2,7-(9,9-dihexylfluorene) polyfluorenes with naphthylimide (NI) and anthraquinone (AQ) electron-acceptor end traps produces excitons that form charge transfer states at the end traps. Intramolecular singlet exciton transport to end traps was examined by steady state fluorescence for polyfluorenes of 17 to 127 repeat units in chloroform, dimethylformamide (DMF), tetrahydrofuran (THF), and p-xylene. End traps capture excitons and form charge transfer (CT) states at all polymer lengths and in all solvents. The CT nature of the end-trapped states is confirmed by their fluorescence spectra, solvent and trap group dependence and DFT descriptions. Quantum yields of CT fluorescence are as large as 46%. This strong CT emission is understood in terms of intensity borrowing. Energies of the CT states from onsets of the fluorescence spectra give the depths of the traps which vary with solvent polarity. For NI end traps the trap depths are 0.06 (p-xylene), 0.13 (THF) and 0.19 eV (CHCl3). For AQ, CT fluorescence could be observed only in p-xylene where the trap depth is 0.27 eV. Quantum yields, emission energies, charge transfer energies, solvent reorganization and vibrational energies were calculated. Fluorescence measurements on chains >100 repeat units indicate that end traps capture ~50% of the excitons, and that the exciton diffusion length LD =34 nm, which is much larger than diffusion lengths reported in polymer films or than previously known for diffusion along isolated chains. The efficiency of exciton capture depends on chain length, but not on trap depth, solvent polarity or which trap group is present.

  11. Subunits of highly Fluorescent Protein R-Phycoerythrin as Probes for Cell Imaging and Single-Molecule Detection

    SciTech Connect (OSTI)

    Dragan Isailovic

    2005-12-17

    The purposes of our research were: (1) To characterize subunits of highly fluorescent protein R-Phycoerythrin (R-PE) and check their suitability for single-molecule detection (SMD) and cell imaging, (2) To extend the use of R-PE subunits through design of similar proteins that will be used as probes for microscopy and spectral imaging in a single cell, and (3) To demonstrate a high-throughput spectral imaging method that will rival spectral flow cytometry in the analysis of individual cells. We first demonstrated that R-PE subunits have spectroscopic and structural characteristics that make them suitable for SMD. Subunits were isolated from R-PE by high-performance liquid chromatography (HPLC) and detected as single molecules by total internal reflection fluorescence microscopy (TIRFM). In addition, R-PE subunits and their enzymatic digests were characterized by several separation and detection methods including HPLC, capillary electrophoresis, sodium dodecyl sulfate-polyacrilamide gel electrophoresis (SDS-PAGE) and HPLC-electrospray ionization mass spectrometry (ESI-MS). Favorable absorption and fluorescence of the R-PE subunits and digest peptides originate from phycoerythrobilin (PEB) and phycourobilin (PUB) chromophores that are covalently attached to cysteine residues. High absorption coefficients and strong fluorescence (even under denaturing conditions), broad excitation and emission fluorescence spectra in the visible region of electromagnetic spectrum, and relatively low molecular weights make these molecules suitable for use as fluorescence labels of biomolecules and cells. We further designed fluorescent proteins both in vitro and in vivo (in Escherichia coli) based on the highly specific attachment of PEB chromophore to genetically expressed apo-subunits of R-PE. In one example, apo-alpha and apo-beta R-PE subunits were cloned from red algae Polisiphonia boldii (P. boldii), and expressed in E. coli. Although expressed apo-subunits formed inclusion

  12. Method for detecting binding events using micro-X-ray fluorescence spectrometry

    DOE Patents [OSTI]

    Warner, Benjamin P.; Havrilla, George J.; Mann, Grace

    2010-12-28

    Method for detecting binding events using micro-X-ray fluorescence spectrometry. Receptors are exposed to at least one potential binder and arrayed on a substrate support. Each member of the array is exposed to X-ray radiation. The magnitude of a detectable X-ray fluorescence signal for at least one element can be used to determine whether a binding event between a binder and a receptor has occurred, and can provide information related to the extent of binding between the binder and receptor.

  13. Fast repetition rate (FRR) fluorometer and method for measuring fluorescence and photosynthetic parameters

    DOE Patents [OSTI]

    Kolber, Zbigniew; Falkowski, Paul

    1995-06-20

    A fast repetition rate fluorometer device and method for measuring in vivo fluorescence of phytoplankton or higher plants chlorophyll and photosynthetic parameters of phytoplankton or higher plants by illuminating the phytoplankton or higher plants with a series of fast repetition rate excitation flashes effective to bring about and measure resultant changes in fluorescence yield of their Photosystem II. The series of fast repetition rate excitation flashes has a predetermined energy per flash and a rate greater than 10,000 Hz. Also, disclosed is a flasher circuit for producing the series of fast repetition rate flashes.

  14. Fast repetition rate (FRR) fluorometer and method for measuring fluorescence and photosynthetic parameters

    DOE Patents [OSTI]

    Kolber, Z.; Falkowski, P.

    1995-06-20

    A fast repetition rate fluorometer device and method for measuring in vivo fluorescence of phytoplankton or higher plants chlorophyll and photosynthetic parameters of phytoplankton or higher plants is revealed. The phytoplankton or higher plants are illuminated with a series of fast repetition rate excitation flashes effective to bring about and measure resultant changes in fluorescence yield of their Photosystem II. The series of fast repetition rate excitation flashes has a predetermined energy per flash and a rate greater than 10,000 Hz. Also, disclosed is a flasher circuit for producing the series of fast repetition rate flashes. 14 figs.

  15. High efficiency and brightness fluorescent organic light emitting diode by triplet-triplet fusion

    DOE Patents [OSTI]

    Forrest, Stephen; Zhang, Yifan

    2015-02-10

    A first device is provided. The first device further comprises an organic light emitting device. The organic light emitting device further comprises an anode, a cathode, and an emissive layer disposed between the anode and the cathode. The emissive layer may include an organic host compound and at least one organic emitting compound capable of fluorescent emission at room temperature. Various configurations are described for providing a range of current densities in which T-T fusion dominates over S-T annihilation, leading to very high efficiency fluorescent OLEDs.

  16. X-RAY FLUORESCENCE ANALYSIS OF HANFORD LOW ACTIVITY WASTE SIMULANTS METHOD DEVELOPMENT

    SciTech Connect (OSTI)

    Jurgensen, A; David Missimer, D; Ronny Rutherford, R

    2007-08-08

    The x-ray fluorescence laboratory (XRF) in the Analytical Development Directorate (ADD) of the Savannah River National Laboratory (SRNL) was requested to develop an x-ray fluorescence spectrometry method for elemental characterization of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) pretreated low activity waste (LAW) stream to the LAW Vitrification Plant. The WTP is evaluating the potential for using XRF as a rapid turnaround technique to support LAW product compliance and glass former batching. The overall objective of this task was to develop an XRF analytical method that provides rapid turnaround time (<8 hours), while providing sufficient accuracy and precision to determine variations in waste.

  17. Three-dimensional x-ray fluorescence mapping of a gold nanoparticle-loaded phantom

    SciTech Connect (OSTI)

    Ren, Liqiang; Wu, Di; Li, Yuhua; Liu, Hong; Wang, Ge; Wu, Xizeng

    2014-03-15

    Purpose : X-ray fluorescence (XRF) is a promising technique with sufficient specificity and sensitivity for identifying and quantifying features in small samples containing high atomic number (Z) materials such as iodine, gadolinium, and gold. In this study, the feasibility of applying XRF to early breast cancer diagnosis and treatment is studied using a novel approach for three-dimensional (3D) x-ray fluorescence mapping (XFM) of gold nanoparticle (GNP)-loaded objects in a physical phantom at the technical level. Methods : All the theoretical analysis and experiments are conducted under the condition of using x-ray pencil beam and a compactly integrated x-ray spectrometer. The penetrability of the fluorescence x-rays from GNPs is first investigated by adopting a combination of BR12 with 70 mm/50 mm in thickness on the excitation/emission path to mimic the possible position of tumor goldin vivo. Then, a physical phantom made of BR12 is designed to translate in 3D space with three precise linear stages and subsequently the step by step XFM scanning is performed. The experimental technique named as background subtraction is applied to isolate the gold fluorescence from each spectrum obtained by the spectrometer. Afterwards, the attenuations of both the incident primary x-ray beam with energies beyond the gold K-edge energy (80.725 keV) and the isolated gold K{sub α} fluorescence x-rays (65.99 –69.80 keV) acquired after background subtraction are well calibrated, and finally the unattenuated K{sub α} fluorescence counts are used to realize mapping reconstruction and to describe the linear relationship between gold fluorescence counts and corresponding concentration of gold solutions. Results : The penetration results show that the goldK{sub α} fluorescence x-rays have sufficient penetrability for this phantom study, and the reconstructed mapping results indicate that both the spatial distribution and relative concentration of GNPs within the designed BR12 phantom

  18. Measurement of Pressure Dependent Fluorescence Yield of Air: Calibration Factor for UHECR Detectors

    SciTech Connect (OSTI)

    Belz, J.W.; Burt, G.W.; Cao, Z.; Chang, F.Y.; Chen, C.C.; Chen, C.W.; Chen, P.; Field, C.; Findlay, J.; Huntemeyer, Petra; Huang, M.A.; Hwang, W.-Y.P.; Iverson, R.; Jones, B.F.; Jui, C.C.H.; Kirn, M.; Lin, G.-L.; Loh, E.C.; Maestas, M.M.; Manago, N.; Martens, K.; /Montana U. /Utah U. /Taiwan, Natl. Taiwan U. /SLAC /Rutgers U., Piscataway

    2005-07-06

    In a test experiment at the Final Focus Test Beam of the Stanford Linear Accelerator Center, the fluorescence yield of 28.5 GeV electrons in air and nitrogen was measured. The measured photon yields between 300 and 400 nm at 1 atm and 29 C are Y(760 Torr){sup air} = 4.42 {+-} 0.73 and Y(760 Torr){sup N{sub 2}} = 29.2 {+-} 4.8 photons per electron per meter. Assuming that the fluorescence yield is proportional to the energy deposition of a charged particle traveling through air, good agreement with measurements at lower particle energies is observed.

  19. Fluorescent and cathodoluminescent phosphors structurally related to sodalite

    DOE Patents [OSTI]

    Phillips, M.L.F.; Shea, L.E.

    1998-09-29

    Blue, quantum-confined phosphors are disclosed for field-emission displays made by reducing metal (M) sulfoaluminates at high temperature. This yields phases of the type M{sub 4}(AlO{sub 2}){sub 6}S. Bulk sulfide contaminant mixed with the reduced sulfoaluminate phase is removed by treating it with a chelating agent in nonaqueous solution. A photometric cathodoluminescence efficiency of 9 lumen/watt at 1,000 V for Sr{sub 3}PbS(AlO{sub 2}){sub 6} is observed. Undoped Sr{sub 4}S(AlO){sub 6} displays 5 lumen/watt at 1,000 V, with excellent blue chromatic saturation. 2 figs.

  20. High energy resolution five-crystal spectrometer for high quality fluorescence and absorption measurements on an x-ray absorption spectroscopy beamline

    SciTech Connect (OSTI)

    Llorens, Isabelle; Lahera, Eric; Delnet, William; Proux, Olivier; Dermigny, Quentin; Gelebart, Frederic; Morand, Marc; Shukla, Abhay; Bardou, Nathalie; Ulrich, Olivier; and others

    2012-06-15

    Fluorescence detection is classically achieved with a solid state detector (SSD) on x-ray absorption spectroscopy (XAS) beamlines. This kind of detection however presents some limitations related to the limited energy resolution and saturation. Crystal analyzer spectrometers (CAS) based on a Johann-type geometry have been developed to overcome these limitations. We have tested and installed such a system on the BM30B/CRG-FAME XAS beamline at the ESRF dedicated to the structural investigation of very dilute systems in environmental, material and biological sciences. The spectrometer has been designed to be a mobile device for easy integration in multi-purpose hard x-ray synchrotron beamlines or even with a laboratory x-ray source. The CAS allows to collect x-ray photons from a large solid angle with five spherically bent crystals. It will cover a large energy range allowing to probe fluorescence lines characteristic of all the elements from Ca (Z = 20) to U (Z = 92). It provides an energy resolution of 1-2 eV. XAS spectroscopy is the main application of this device even if other spectroscopic techniques (RIXS, XES, XRS, etc.) can be also achieved with it. The performances of the CAS are illustrated by two experiments that are difficult or impossible to perform with SSD and the complementarity of the CAS vs SSD detectors is discussed.

  1. Property:Water Type | Open Energy Information

    Open Energy Info (EERE)

    Type Jump to: navigation, search Property Name Water Type Property Type String Pages using the property "Water Type" Showing 25 pages using this property. (previous 25) (next 25) 1...

  2. Structure of the red fluorescent protein from a lancelet (Branchiostoma lanceolatum): a novel GYG chromophore covalently bound to a nearby tyrosine

    SciTech Connect (OSTI)

    Pletnev, Vladimir Z. Pletneva, Nadya V.; Lukyanov, Konstantin A.; Souslova, Ekaterina A.; Fradkov, Arkady F.; Chudakov, Dmitry M.; Chepurnykh, Tatyana; Yampolsky, Ilia V.; Wlodawer, Alexander; Dauter, Zbigniew; Pletnev, Sergei

    2013-09-01

    The crystal structure of the novel red emitting fluorescent protein from lancelet Branchiostoma lanceolatum (Chordata) revealed an unusual five residues cyclic unit comprising Gly58-Tyr59-Gly60 chromophore, the following Phe61 and Tyr62 covalently bound to chromophore Tyr59. A key property of proteins of the green fluorescent protein (GFP) family is their ability to form a chromophore group by post-translational modifications of internal amino acids, e.g. Ser65-Tyr66-Gly67 in GFP from the jellyfish Aequorea victoria (Cnidaria). Numerous structural studies have demonstrated that the green GFP-like chromophore represents the ‘core’ structure, which can be extended in red-shifted proteins owing to modifications of the protein backbone at the first chromophore-forming position. Here, the three-dimensional structures of green laGFP (λ{sub ex}/λ{sub em} = 502/511 nm) and red laRFP (λ{sub ex}/λ{sub em} ≃ 521/592 nm), which are fluorescent proteins (FPs) from the lancelet Branchiostoma lanceolatum (Chordata), were determined together with the structure of a red variant laRFP-ΔS83 (deletion of Ser83) with improved folding. Lancelet FPs are evolutionarily distant and share only ∼20% sequence identity with cnidarian FPs, which have been extensively characterized and widely used as genetically encoded probes. The structure of red-emitting laRFP revealed three exceptional features that have not been observed in wild-type fluorescent proteins from Cnidaria reported to date: (i) an unusual chromophore-forming sequence Gly58-Tyr59-Gly60, (ii) the presence of Gln211 at the position of the conserved catalytic Glu (Glu222 in Aequorea GFP), which proved to be crucial for chromophore formation, and (iii) the absence of modifications typical of known red chromophores and the presence of an extremely unusual covalent bond between the Tyr59 C{sup β} atom and the hydroxyl of the proximal Tyr62. The impact of this covalent bond on the red emission and the large Stokes shift (

  3. ORISE: Enhancing Energy Efficiency Through Peer Review

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Enhancing Energy Efficiency ORISE scientific peer review helps evaluate technologies that advance renewable energy ORISE Reviews and Evaluates Technologies that Advance Energy Efficiency In addition to renewable energy and changes in individual behavior, energy efficiency is generally achieved through the development of more efficient technologies. Buildings are being constructed with more energy efficient systems, fluorescent light bulbs are replacing incandescent lights, and new vehicle

  4. Today LED Holiday Lights, Tomorrow the World?

    SciTech Connect (OSTI)

    Gordon, Kelly L.

    2004-12-20

    This article for The APEM Advantage, the quarterly newsletter of the Association of Professional Energy Managers (APEM) describes the recent increase in the popularity of light emitting diode (LED) lighting and compares LED light output with that of incandescent and compact fluorescent lighting.

  5. Filter-fluorescer measurement of low-voltage simulator x-ray energy spectra

    SciTech Connect (OSTI)

    Baldwin, G.T.; Craven, R.E.

    1986-01-01

    X-ray energy spectra of the Maxwell Laboratories MBS and Physics International Pulserad 737 were measured using an eight-channel filter-fluorescer array. The PHOSCAT computer code was used to calculate channel response functions, and the UFO code to unfold spectrum.

  6. Simultaneous cryo X-ray ptychographic and fluorescence microscopy of green algae

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Deng, Junjing; Vine, David J.; Chen, Si; Nashed, Youssef S. G.; Jin, Qiaoling; Phillips, Nicholas W.; Peterka, Tom; Ross, Rob; Vogt, Stefan; Jacobsen, Chris J.

    2015-02-24

    Trace metals play important roles in normal and in disease-causing biological functions. X-ray fluorescence microscopy reveals trace elements with no dependence on binding affinities (unlike with visible light fluorophores) and with improved sensitivity relative to electron probes. However, X-ray fluorescence is not very sensitive for showing the light elements that comprise the majority of cellular material. Here we show that X-ray ptychography can be combined with fluorescence to image both cellular structure and trace element distribution in frozen-hydrated cells at cryogenic temperatures, with high structural and chemical fidelity. Ptychographic reconstruction algorithms deliver phase and absorption contrast images at a resolutionmore » beyond that of the illuminating lens or beam size. Using 5.2-keV X-rays, we have obtained sub–30-nm resolution structural images and ~90-nm–resolution fluorescence images of several elements in frozen-hydrated green algae. This combined approach offers a way to study the role of trace elements in their structural context.« less

  7. Dimeric fluorescent energy transfer dyes comprising asymmetric cyanine azole-indolenine chromophores

    DOE Patents [OSTI]

    Glazer, Alexander N.; Benson, Scott C.

    1996-01-01

    Novel fluorescent DNA-staining dyes are provided combining asymmetric cyanine azole-indolenine dyes, which provide for strong DNA affinity, large Stokes shifts and emission in the red region of the spectrum. The dyes find particular application in gel electrophoresis and for labels which may be bound to a variety of compositions in a variety of contexts.

  8. Correlative Electron and Fluorescence Microscopy of Magnetotactic Bacteria in Liquid: Toward In Vivo Imaging

    SciTech Connect (OSTI)

    Woehl, Taylor J.; Kashyap, Sanjay; Firlar, Emre; Perez-Gonzalez, Teresa; Faivre, Damien; Trubitsyn, Denis; Bazylinski, Dennis A.; Prozorov, Tanya

    2014-10-31

    Magnetotactic bacteria biomineralize ordered chains of uniform, membrane-bound magnetite or greigite nanocrystals that exhibit nearly perfect crystal structures and species-specific morphologies. Transmission electron microscopy (TEM) is a critical technique for providing information regarding the organization of cellular and magnetite structures in these microorganisms. However, conventional TEM can only be used to image air-dried or vitrified bacteria removed from their natural environment. Here we present a correlative scanning TEM (STEM) and fluorescence microscopy technique for imaging viable cells of Magnetospirillum magneticum strain AMB-1 in liquid using an in situ fluid cell TEM holder. Fluorescently labeled cells were immobilized on microchip window surfaces and visualized in a fluid cell with STEM, followed by correlative fluorescence imaging to verify their membrane integrity. Notably, the post-STEM fluorescence imaging indicated that the bacterial cell wall membrane did not sustain radiation damage during STEM imaging at low electron dose conditions. We investigated the effects of radiation damage and sample preparation on the bacteria viability and found that approximately 50% of the bacterial membranes remained intact after an hour in the fluid cell, decreasing to ~30% after two hours. These results represent a first step toward in vivo studies of magnetite biomineralization in magnetotactic bacteria.

  9. Correlative Electron and Fluorescence Microscopy of Magnetotactic Bacteria in Liquid: Toward In Vivo Imaging

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Woehl, Taylor J.; Kashyap, Sanjay; Firlar, Emre; Perez-Gonzalez, Teresa; Faivre, Damien; Trubitsyn, Denis; Bazylinski, Dennis A.; Prozorov, Tanya

    2014-10-31

    Magnetotactic bacteria biomineralize ordered chains of uniform, membrane-bound magnetite or greigite nanocrystals that exhibit nearly perfect crystal structures and species-specific morphologies. Transmission electron microscopy (TEM) is a critical technique for providing information regarding the organization of cellular and magnetite structures in these microorganisms. However, conventional TEM can only be used to image air-dried or vitrified bacteria removed from their natural environment. Here we present a correlative scanning TEM (STEM) and fluorescence microscopy technique for imaging viable cells of Magnetospirillum magneticum strain AMB-1 in liquid using an in situ fluid cell TEM holder. Fluorescently labeled cells were immobilized on microchip windowmore » surfaces and visualized in a fluid cell with STEM, followed by correlative fluorescence imaging to verify their membrane integrity. Notably, the post-STEM fluorescence imaging indicated that the bacterial cell wall membrane did not sustain radiation damage during STEM imaging at low electron dose conditions. We investigated the effects of radiation damage and sample preparation on the bacteria viability and found that approximately 50% of the bacterial membranes remained intact after an hour in the fluid cell, decreasing to ~30% after two hours. These results represent a first step toward in vivo studies of magnetite biomineralization in magnetotactic bacteria.« less

  10. Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry

    DOE Patents [OSTI]

    Siminovitch, Michael

    1998-01-01

    A novel design for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment.

  11. Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry

    DOE Patents [OSTI]

    Siminovitch, M.

    1998-02-10

    A novel design is described for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment. 9 figs.

  12. Fluorescence technique for on-line monitoring of state of hydrogen-producing microorganisms

    DOE Patents [OSTI]

    Seibert, Michael; Makarova, Valeriya; Tsygankov, Anatoly A.; Rubin, Andrew B.

    2007-06-12

    In situ fluorescence method to monitor state of sulfur-deprived algal culture's ability to produce H.sub.2 under sulfur depletion, comprising: a) providing sulfur-deprived algal culture; b) illuminating culture; c) measuring onset of H.sub.2 percentage in produced gas phase at multiple times to ascertain point immediately after anerobiosis to obtain H.sub.2 data as function of time; and d) determining any abrupt change in three in situ fluorescence parameters; i) increase in F.sub.t (steady-state level of chlorophyll fluorescence in light adapted cells); ii) decrease in F.sub.m', (maximal saturating light induced fluorescence level in light adapted cells); and iii) decrease in .DELTA.F/F.sub.m'=(F.sub.m'-F.sub.t)/F.sub.m' (calculated photochemical activity of photosystem II (PSII) signaling full reduction of plastoquinone pool between PSII and PSI, which indicates start of anaerobic conditions that induces synthesis of hydrogenase enzyme for subsequent H.sub.2 production that signal oxidation of plastoquinone pool asmain factor to regulate H.sub.2 under sulfur depletion.

  13. Synthesis and preliminary biological evaluations of fluorescent or 149Promethium labeled Trastuzumab-polyethylenimine

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Fitzsimmons, Jonathan; Nayak, Tapan; Cutler, Cathy; Atcher, Robert

    2015-12-30

    Radioimmunotherapy utilize a targeting antibody coupled to a therapeutic isotope to target and treat a tumor or disease. In this study we examine the synthesis and cell binding of a polymer scaffold containing a radiotherapeutic isotope and a targeting antibody. Methods: The multistep synthesis of a fluorescent or 149Promethium-labeled Trastuzumab-polyethyleneimine (PEI), Trastuzumab, or PEI is described. In vitro uptake, internalization and/or the binding affinity to the Her2/neu expressing human breast adenocarcinoma SKBr3 cells was investigated with the labeled compounds. Fluorescent-labeled Trastuzumab-PEI was internalized more into cells at 2 and 18 h than fluorescent-labeled Trastuzumab or PEI. The fluorescent-labeled Trastuzumab wasmore » concentrated on the cell surface at 2 and 18 h and the labeled PEI had minimal uptake. DOTA-PEI was prepared and contained an average of 16 chelates per PEI; the compound was radio-labeled with 149Promethium and conjugated to Trastuzumab. The purified 149Pm-DOTA-PEI-Trastuzumab had a radiochemical purity of 96.7% and a specific activity of 0.118 TBq/g. The compound demonstrated a dissociation constant for the Her2/neu receptor of 20.30 ± 6.91 nM. In conclusion, the results indicate the DOTA-PEI-Trastuzumab compound has potential as a targeted therapeutic carrier, and future in vivo studies should be performed.« less

  14. Sunna 535-nm photo-fluorescent film dosimeter response to different environmental conditions

    SciTech Connect (OSTI)

    Murphy, Mark K.; Kovacs, Andras; Mclaughlin, William L.; Miller, Steven D.); Puhl, James M.

    2003-12-01

    Evaluations on the influence of environmental variabilities on the red fluorescence component of the Sunna Model? photo-fluorescent dosimeter have previously been reported. This present paper describes the environmental effects on the response of the green fluorescence component of the same dosimeter, which is manufactured using the injection molding technique. The results presented include temperature, relative humidity, and light influences both during and after irradiation. The green fluorescence signal shows a significant dependence on irradiation temperature below room temperature at 1%/C. Above room temperature (approximately 24C to 60C), the irradiation temperature effect varies from -0.1-1.0%/C, depending on the absorbed dose level. For facilities with irradiation temperatures between 30-60C and absorbed dose levels above 10 kGy, irradiation temperature effects are minimal. Light-effects results indicate that the dosimeter is influenced by ultraviolet and blue wavelengths during irradiation as well as during the post-irradiation stabilization period (approx. 22 hours), requiring the use of light-tight packaging. Results also show that the dosimeter exhibits negligible effects from ambient moisture during and after irradiation when in the range of 33-95% relative humidity.

  15. Design and evaluation of a device for fast multispectral time-resolved fluorescence spectroscopy and imaging

    SciTech Connect (OSTI)

    Yankelevich, Diego R.; Department of Biomedical Engineering, University of California, 451 Health Sciences Drive, Davis, California 95616 ; Ma, Dinglong; Liu, Jing; Sun, Yang; Sun, Yinghua; Bec, Julien; Marcu, Laura; Elson, Daniel S.

    2014-03-15

    The application of time-resolved fluorescence spectroscopy (TRFS) to in vivo tissue diagnosis requires a method for fast acquisition of fluorescence decay profiles in multiple spectral bands. This study focusses on development of a clinically compatible fiber-optic based multispectral TRFS (ms-TRFS) system together with validation of its accuracy and precision for fluorescence lifetime measurements. It also presents the expansion of this technique into an imaging spectroscopy method. A tandem array of dichroic beamsplitters and filters was used to record TRFS decay profiles at four distinct spectral bands where biological tissue typically presents fluorescence emission maxima, namely, 390, 452, 542, and 629 nm. Each emission channel was temporally separated by using transmission delays through 200 μm diameter multimode optical fibers of 1, 10, 19, and 28 m lengths. A Laguerre-expansion deconvolution algorithm was used to compensate for modal dispersion inherent to large diameter optical fibers and the finite bandwidth of detectors and digitizers. The system was found to be highly efficient and fast requiring a few nano-Joule of laser pulse energy and <1 ms per point measurement, respectively, for the detection of tissue autofluorescent components. Organic and biological chromophores with lifetimes that spanned a 0.8–7 ns range were used for system validation, and the measured lifetimes from the organic fluorophores deviated by less than 10% from values reported in the literature. Multi-spectral lifetime images of organic dye solutions contained in glass capillary tubes were recorded by raster scanning the single fiber probe in a 2D plane to validate the system as an imaging tool. The lifetime measurement variability was measured indicating that the system provides reproducible results with a standard deviation smaller than 50 ps. The ms-TRFS is a compact apparatus that makes possible the fast, accurate, and precise multispectral time-resolved fluorescence

  16. Recovery of yttrium from cathode ray tubes and lamps’ fluorescent powders: experimental results and economic simulation

    SciTech Connect (OSTI)

    Innocenzi, V. De Michelis, I.; Ferella, F.; Vegliò, F.

    2013-11-15

    Highlights: • Fluorescent powder of lamps. • Fluorescent powder of cathode ray rubes. • Recovery of yttrium from fluorescent powders. • Economic simulation for the processes to recover yttrium from WEEE. - Abstract: In this paper, yttrium recovery from fluorescent powder of lamps and cathode ray tubes (CRTs) is described. The process for treating these materials includes the following: (a) acid leaching, (b) purification of the leach liquors using sodium hydroxide and sodium sulfide, (c) precipitation of yttrium using oxalic acid, and (d) calcinations of oxalates for production of yttrium oxides. Experimental results have shown that process conditions necessary to purify the solutions and recover yttrium strongly depend on composition of the leach liquor, in other words, whether the powder comes from treatment of CRTs or lamp. In the optimal experimental conditions, the recoveries of yttrium oxide are about 95%, 55%, and 65% for CRT, lamps, and CRT/lamp mixture (called MIX) powders, respectively. The lower yields obtained during treatments of MIX and lamp powders are probably due to the co-precipitation of yttrium together with other metals contained in the lamps powder only. Yttrium loss can be reduced to minimum changing the experimental conditions with respect to the case of the CRT process. In any case, the purity of final products from CRT, lamps, and MIX is greater than 95%. Moreover, the possibility to treat simultaneously both CRT and lamp powders is very important and interesting from an industrial point of view since it could be possible to run a single plant treating fluorescent powder coming from two different electronic wastes.

  17. Estimate of federal relighting potential and demand for efficient lighting products

    SciTech Connect (OSTI)

    Shankle, S.A.; Dirks, J.A.; Elliott, D.B.; Richman, E.E.; Grover, S.E.

    1993-11-01

    The increasing level of electric utility rebates for energy-efficient lighting retrofits has recently prompted concern over the adequacy of the market supply of energy-efficient lighting products (Energy User News 1991). In support of the U.S. Department of Energy`s Federal Energy Management Program, Pacific Northwest Laboratory (PNL) has developed an estimate of the total potential for energy-efficient lighting retrofits in federally owned buildings. This estimate can be used to address the issue of the impact of federal relighting projects on the supply of energy-efficient lighting products. The estimate was developed in 1992, using 1991 data. Any investments in energy-efficient lighting products that occurred in 1992 will reduce the potential estimated here. This analysis proceeds by estimating the existing stock of lighting fixtures in federally owned buildings. The lighting technology screening matrix is then used to determine the minimum life-cycle cost retrofit for each type of existing lighting fixture. Estimates of the existing stock are developed for (1) four types of fluorescent lighting fixtures (2-, 3-, and 4-lamp, F40 4-foot fixtures, and 2-lamp, F96 8-foot fixtures, all with standard magnetic ballasts); (2) one type of incandescent fixture (a 75-watt single bulb fixture); and (3) one type of exit sign (containing two 20-watt incandescent bulbs). Estimates of the existing stock of lighting fixtures in federally owned buildings, estimates of the total potential demand for energy-efficient lighting products if all cost-effective retrofits were undertaken immediately, and total potential annual energy savings (in MWh and dollars), the total investment required to obtain the energy savings and the present value of the efficiency investment, are presented.

  18. ISSUANCE 2015-06-17: Energy Conservation Standards for Fluorescent Lamp Ballasts, Notice of Public Meeting and Availability of the Framework Document

    Broader source: Energy.gov [DOE]

    Energy Conservation Standards for Fluorescent Lamp Ballasts, Notice of Public Meeting and Availability of the Framework Document

  19. ISSUANCE 2015-08-14: Energy Efficiency Program for Consumer Products: Energy Conservation Standards for Fluorescent Lamp Ballasts, Reopening of the Comment Period

    Broader source: Energy.gov [DOE]

    Energy Efficiency Program for Consumer Products: Energy Conservation Standards for Fluorescent Lamp Ballasts, Reopening of the Comment Period

  20. Distinct roles of the photosystem II protein PsbS and zeaxanthin in the regulation of light harvesting in plants revealed by fluorescence lifetime snapshots

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Sylak-Glassman, Emily J.; Malnoë, Alizée; De Re, Eleonora; Brooks, Matthew D.; Fischer, Alexandra Lee; Niyogi, Krishna K.; Fleming, Graham R.

    2014-10-01

    The photosystem II (PSII) protein PsbS and the enzyme violaxanthin deepoxidase (VDE) are known to influence the dynamics of energy-dependent quenching (qE), the component of nonphotochemical quenching (NPQ) that allows plants to respond to fast fluctuations in light intensity. Although the absence of PsbS and VDE has been shown to change the amount of quenching, there have not been any measurements that can detect whether the presence of these proteins alters the type of quenching that occurs. The chlorophyll fluorescence lifetime probes the excited-state chlorophyll relaxation dynamics and can be used to determine the amount of quenching as well asmore » whether two different genotypes with the same amount of NPQ have similar dynamics of excited-state chlorophyll relaxation. We measured the fluorescence lifetimes on whole leaves of Arabidopsis thaliana throughout the induction and relaxation of NPQ for wild type and the qE mutants, npq4, which lacks PsbS; npq1, which lacks VDE and cannot convert violaxanthin to zeaxanthin; and npq1 npq4, which lacks both VDE and PsbS. These measurements show that although PsbS changes the amount of quenching and the rate at which quenching turns on, it does not affect the relaxation dynamics of excited chlorophyll during quenching. In addition, the data suggest that PsbS responds not only to ΔpH but also to the Δψ across the thylakoid membrane. In contrast, the presence of VDE, which is necessary for the accumulation of zeaxanthin, affects the excited-state chlorophyll relaxation dynamics.« less

  1. Distinct roles of the photosystem II protein PsbS and zeaxanthin in the regulation of light harvesting in plants revealed by fluorescence lifetime snapshots

    SciTech Connect (OSTI)

    Sylak-Glassman, Emily J.; Malnoë, Alizée; De Re, Eleonora; Brooks, Matthew D.; Fischer, Alexandra Lee; Niyogi, Krishna K.; Fleming, Graham R.

    2014-10-01

    The photosystem II (PSII) protein PsbS and the enzyme violaxanthin deepoxidase (VDE) are known to influence the dynamics of energy-dependent quenching (qE), the component of nonphotochemical quenching (NPQ) that allows plants to respond to fast fluctuations in light intensity. Although the absence of PsbS and VDE has been shown to change the amount of quenching, there have not been any measurements that can detect whether the presence of these proteins alters the type of quenching that occurs. The chlorophyll fluorescence lifetime probes the excited-state chlorophyll relaxation dynamics and can be used to determine the amount of quenching as well as whether two different genotypes with the same amount of NPQ have similar dynamics of excited-state chlorophyll relaxation. We measured the fluorescence lifetimes on whole leaves of Arabidopsis thaliana throughout the induction and relaxation of NPQ for wild type and the qE mutants, npq4, which lacks PsbS; npq1, which lacks VDE and cannot convert violaxanthin to zeaxanthin; and npq1 npq4, which lacks both VDE and PsbS. These measurements show that although PsbS changes the amount of quenching and the rate at which quenching turns on, it does not affect the relaxation dynamics of excited chlorophyll during quenching. In addition, the data suggest that PsbS responds not only to ΔpH but also to the Δψ across the thylakoid membrane. In contrast, the presence of VDE, which is necessary for the accumulation of zeaxanthin, affects the excited-state chlorophyll relaxation dynamics.

  2. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology

    SciTech Connect (OSTI)

    Not Available

    1993-11-01

    The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

  3. IMPROVED TYPE OF FUEL ELEMENT

    DOE Patents [OSTI]

    Monson, H.O.

    1961-01-24

    A radiator-type fuel block assembly is described. It has a hexagonal body of neutron fissionable material having a plurality of longitudinal equal- spaced coolant channels therein aligned in rows parallel to each face of the hexagonal body. Each of these coolant channels is hexagonally shaped with the corners rounded and enlarged and the assembly has a maximum temperature isothermal line around each channel which is approximately straight and equidistant between adjacent channels.

  4. The use of fluorescence spectroscopy to monitor operation in petroleum hydrocracking units

    SciTech Connect (OSTI)

    Fetzer, J.C.

    1994-12-31

    The catalytic hydrocracking is used in refineries to convert petroleum-derived feedstocks into motor fuels and lubricating oils. Polycyclic aromatic hydrocarbons (PAHs) are produced as by-products in the process. The PAHs lead to a variety of process and product problems. The specific PAHs produced have been identified through the use of HPLC-DAD and fluorescence and mass spectroscopies. A set of production reactions have been determined that explain the observed PAHs. A synchronous-scanning fluorescence (SSF) method has been used to determine the levels of several kerge PAHs, including dicoronylene. This fifteen-ring PAH is the main cause of plugging in process piping, which necessitates expensive shutdown and cleaning of the process. This PAH is too large to be amenable to chromatographic methods. Its extremely low solubility, in a mixture of other PAHs show the advantages of SSF.

  5. Enhanced-locality fiber-optic two-photon-fluorescence live-brain interrogation

    SciTech Connect (OSTI)

    Fedotov, I. V.; Doronina-Amitonova, L. V.; Sidorov-Biryukov, D. A.; Fedotov, A. B.; Anokhin, K. V.; Kilin, S. Ya.; Sakoda, K.; Zheltikov, A. M.

    2014-02-24

    Two-photon excitation is shown to substantially enhance the locality of fiber-based optical interrogation of strongly scattering biotissues. In our experiments, a high-numerical-aperture, large-core-are fiber probe is used to deliver the 200-fs output of a 100-MHz mode-locked ytterbium fiber laser to samples of live mouse brain, induce two-photon fluorescence of nitrogen–vacancy centers in diamond markers in brain sample. Fiber probes with a high numerical aperture and a large core area are shown to enable locality enhancement in fiber-laser–fiber-probe two-photon brain excitation and interrogation without sacrificing the efficiency of fluorescence response collection.

  6. Highly fluorescent silver nanoclusters in alumina-silica composite optical fiber

    SciTech Connect (OSTI)

    Halder, A.; Chattopadhyay, R.; Majumder, S.; Paul, M. C.; Das, S.; Bhadra, S. K.; Bysakh, S.; Unnikrishnan, M.

    2015-01-05

    An efficient visible fluorescent optical fiber embedded with silver nanoclusters (Ag-NCs) having size ∼1 nm, uniformly distributed in alumina-silica composite core glass, is reported. Fibers are fabricated in a repetitive controlled way through modified chemical vapour deposition process associated with solution doping technique. Fibers are drawn from the transparent preforms by conventional fiber drawing process. Structural characteristics of the doped fibers are studied using transmission electron microscopy and electron probe micro analysis. The oxidation state of Ag within Ag-NCs is investigated by X-ray photo electron spectroscopy. The observed significant fluorescence of the metal clusters in fabricated fibers is correlated with electronic model. The experimentally observed size dependent absorption of the metal clusters in fabricated fibers is explained with the help of reported results calculated by ab-initio density functional theory. These optical fibers may open up an opportunity of realizing tunable wavelength fiber laser without the help of rare earth elements.

  7. Property:DeviceType | Open Energy Information

    Open Energy Info (EERE)

    DeviceType Property Type String Description Used for MHK ISDB Allows Values Instrument;Sensor Pages using the property "DeviceType" Showing 25 pages using this property. (previous...

  8. Nuclear Resonance Fluorescence at MIT | U.S. DOE Office of Science (SC)

    Office of Science (SC) Website

    Resonance Fluorescence at MIT Nuclear Physics (NP) NP Home About Research Facilities Science Highlights Benefits of NP Applications of Nuclear Science Applications of Nuclear Science Archives Small Business Innovation Research / Small Business Technology Transfer Funding Opportunities Nuclear Science Advisory Committee (NSAC) Community Resources Contact Information Nuclear Physics U.S. Department of Energy SC-26/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301)

  9. 2015-01-28 Issuance: Test Procedure for Fluorescent Lamp Ballasts; Final Rule Correction

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register final rule correction regarding test procedures for fluorescent lamp ballasts, as issued by the Deputy Assistant Secretary for Energy Efficiency on January 28, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

  10. Alexa Fluor-labeled Fluorescent Cellulose Nanocrystals for Bioimaging Solid Cellulose in Spatially Structured Microenvironments

    SciTech Connect (OSTI)

    Grate, Jay W.; Mo, Kai-For; Shin, Yongsoon; Vasdekis, Andreas; Warner, Marvin G.; Kelly, Ryan T.; Orr, Galya; Hu, Dehong; Dehoff, Karl J.; Brockman, Fred J.; Wilkins, Michael J.

    2015-03-18

    Cellulose nanocrystal materials have been labeled with modern Alexa Fluor dyes in a process that first links the dye to a cyanuric chloride molecule. Subsequent reaction with cellulose nanocrystals provides dyed solid microcrystalline cellulose material that can be used for bioimaging and suitable for deposition in films and spatially structured microenvironments. It is demonstrated with single molecular fluorescence microscopy that these films are subject to hydrolysis by cellulose enzymes.

  11. Multispectral UV Fluorescence Detection of a Dilute Constituent in an Optically Dense Matrix

    SciTech Connect (OSTI)

    Chan, O.H.; Gray, P.C., Wehlburg, C.M.; Rubenstein, R.; Tisone, G.C.; Wagner, J.S.

    1998-10-15

    Multispectral UV fluorescence measurements were made of an optically dense medium (fetal bovine serum, FBS) spiked with sodium salicylate at concentrate ions from 0.2 to 500 pg/ml . Analysis of the spectra show that, depending on experimental conditions, reasonably good estimates of concentration can be obtained across the entire range of concentrate ions. Experimental conditions required for recovering these estimates are demonstrated.

  12. Relative fluorescent efficiency of sodium salicylate between 90 and 800 eV

    SciTech Connect (OSTI)

    Angel, G.C.; Samson, J.A.R.; Williams, G.

    1986-01-01

    The relative fluorescent quantum efficiency of sodium salicylate was measured between 90 and 800 eV (138 -15 A) by the use of synchrotron radiation. A general increase in efficiency was observed in this spectral range except for abrupt decreases in efficiency at the carbon and oxygen K-edges. Beyond the oxygen K-edge (532 eV) the efficiency increased linearly with the incident photon energy to the limit of the present observations.

  13. Luminescent studies of fluorescent chromophore-doped silica aerogels for flat panel display applications

    SciTech Connect (OSTI)

    Glauser, S.A.C. [California Univ., Davis, CA (United States). Dept. of Applied Science; Lee, H.W.H. [Lawrence Livermore National Lab., CA (United States)

    1997-04-01

    The remarkable optical and electronic properties of doped and undoped silica aerogels establish their utility as unique, mulitfunctional host materials for fluorescent dyes and other luminescent materials for display and imaging applications. We present results on the photoluminescence, absorption, and photoluminescence excitation spectra of undoped silica aerogels and aerogels doped with Er{sup 3+}, rhodamine 6G (R6G), and fluorescein. 4 refs., 12 figs.

  14. Two-photon fluorescence microscopy signal formation in highly scattering media: theoretical and numerical simulation

    SciTech Connect (OSTI)

    Sergeeva, Ekaterina A; Katichev, A R; Kirillin, M Yu

    2011-01-24

    Using the radiative transfer theory and Monte Carlo simulations, we analyse the effect of scattering in a medium and of the size of the detector pinhole on the formation of the fluorescent signal in standard two-photon fluorescence microscopy (TPFM) systems. The theoretical analysis is based on a small-angle diffusion approximation of the radiative transfer equation, adapted to calculate the propagation of focused infrared radiation in media similar to the biological tissues in their optical properties. The accuracy of the model is evaluated by comparing the calculated excitation intensity in a highly scattering medium with the results of Monte Carlo simulations. To simulate a tightly focused Gaussian beam by the Monte Carlo method, the so called 'ray-optics' approach that correctly takes into account the finite size and shape of the beam waist is applied. It is shown that in the combined confocal and two-photon scanning microscopy systems not equipped with an external 'nondescanned' detector, the scattering significantly affects both the nonlinear excitation efficiency in the medium and the fluorescence collection efficiency of the system. In such systems, the rate of the useful TPFM signal in-depth decay is 1.5 - 2 times higher than in systems equipped with a 'nondescanned' detector. (application of lasers and laser-optical methods in life sciences)

  15. Thermal green protein, an extremely stable, nonaggregating fluorescent protein created by structure-guided surface engineering

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Close, Devin W.; Paul, Craig Don; Langan, Patricia S.; Wilce, Matthew C. J.; Traore, Daouda A. K.; Halfmann, Randal; Rocha, Reginaldo C.; Waldo, Geoffery S.; Payne, Riley J.; Rucker, Joseph B.; et al

    2015-05-08

    In this paper, we describe the engineering and X-ray crystal structure of Thermal Green Protein (TGP), an extremely stable, highly soluble, non-aggregating green fluorescent protein. TGP is a soluble variant of the fluorescent protein eCGP123, which despite being highly stable, has proven to be aggregation-prone. The X-ray crystal structure of eCGP123, also determined within the context of this paper, was used to carry out rational surface engineering to improve its solubility, leading to TGP. The approach involved simultaneously eliminating crystal lattice contacts while increasing the overall negative charge of the protein. Despite intentional disruption of lattice contacts and introduction ofmore » high entropy glutamate side chains, TGP crystallized readily in a number of different conditions and the X-ray crystal structure of TGP was determined to 1.9 Å resolution. The structural reasons for the enhanced stability of TGP and eCGP123 are discussed. We demonstrate the utility of using TGP as a fusion partner in various assays and significantly, in amyloid assays in which the standard fluorescent protein, EGFP, is undesirable because of aberrant oligomerization.« less

  16. A method of measuring gold nanoparticle concentrations by x-ray fluorescence for biomedical applications

    SciTech Connect (OSTI)

    Wu Di; Li Yuhua; Wong, Molly D.; Liu Hong

    2013-05-15

    Purpose: This paper reports a technique that enables the quantitative determination of the concentration of gold nanoparticles (GNPs) through the accurate detection of their fluorescence radiation in the diagnostic x-ray spectrum. Methods: Experimentally, x-ray fluorescence spectra of 1.9 and 15 nm GNP solutions are measured using an x-ray spectrometer, individually and within chicken breast tissue samples. An optimal combination of excitation and emission filters is determined to segregate the fluorescence spectra at 66.99 and 68.80 keV from the background scattering. A roadmap method is developed that subtracts the scattered radiation (acquired before the insertion of GNP solutions) from the signal radiation acquired after the GNP solutions are inserted. Results: The methods effectively minimize the background scattering in the spectrum measurements, showing linear relationships between GNP solutions from 0.1% to 10% weight concentration and from 0.1% to 1.0% weight concentration inside a chicken breast tissue sample. Conclusions: The investigation demonstrated the potential of imaging gold nanoparticles quantitatively in vivo for in-tissue studies, but future studies will be needed to investigate the ability to apply this method to clinical applications.

  17. Thermal green protein, an extremely stable, nonaggregating fluorescent protein created by structure-guided surface engineering

    SciTech Connect (OSTI)

    Close, Devin W.; Paul, Craig Don; Langan, Patricia S.; Wilce, Matthew C. J.; Traore, Daouda A. K.; Halfmann, Randal; Rocha, Reginaldo C.; Waldo, Geoffery S.; Payne, Riley J.; Rucker, Joseph B.; Prescott, Mark; Bradbury, Andrew R. M.

    2015-05-08

    In this paper, we describe the engineering and X-ray crystal structure of Thermal Green Protein (TGP), an extremely stable, highly soluble, non-aggregating green fluorescent protein. TGP is a soluble variant of the fluorescent protein eCGP123, which despite being highly stable, has proven to be aggregation-prone. The X-ray crystal structure of eCGP123, also determined within the context of this paper, was used to carry out rational surface engineering to improve its solubility, leading to TGP. The approach involved simultaneously eliminating crystal lattice contacts while increasing the overall negative charge of the protein. Despite intentional disruption of lattice contacts and introduction of high entropy glutamate side chains, TGP crystallized readily in a number of different conditions and the X-ray crystal structure of TGP was determined to 1.9 Å resolution. The structural reasons for the enhanced stability of TGP and eCGP123 are discussed. We demonstrate the utility of using TGP as a fusion partner in various assays and significantly, in amyloid assays in which the standard fluorescent protein, EGFP, is undesirable because of aberrant oligomerization.

  18. Role of excited state solvent fluctuations on time-dependent fluorescence Stokes shift

    SciTech Connect (OSTI)

    Li, Tanping E-mail: revatik@lsu.edu; Kumar, Revati E-mail: revatik@lsu.edu

    2015-11-07

    We explore the connection between the solvation dynamics of a chromophore upon photon excitation and equilibrium fluctuations of the solvent. Using molecular dynamics simulations, fluorescence Stokes shift for the tryptophan in Staphylococcus nuclease was examined using both nonequilibrium calculations and linear response theory. When the perturbed and unperturbed surfaces exhibit different solvent equilibrium fluctuations, the linear response approach on the former surface shows agreement with the nonequilibrium process. This agreement is excellent when the perturbed surface exhibits Gaussian statistics and qualitative in the case of an isomerization induced non-Gaussian statistics. However, the linear response theory on the unperturbed surface breaks down even in the presence of Gaussian fluctuations. Experiments also provide evidence of the connection between the excited state solvent fluctuations and the total fluorescence shift. These observations indicate that the equilibrium statistics on the excited state surface characterize the relaxation dynamics of the fluorescence Stokes shift. Our studies specifically analyze the Gaussian fluctuations of the solvent in the complex protein environment and further confirm the role of solvent fluctuations on the excited state surface. The results are consistent with previous investigations, found in the literature, of solutes dissolved in liquids.

  19. Lighting Control Types | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Lighting Control Types Lighting Control Types Characteristics of the most common lighting controls for offices and other public buildings are outlined below. Also provided is a ...

  20. Principal Types of Volcanoes | Open Energy Information

    Open Energy Info (EERE)

    Types of Volcanoes Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Principal Types of Volcanoes Abstract Abstract unavailable. Author John Watson...

  1. Type C: Caldera Resource | Open Energy Information

    Open Energy Info (EERE)

    C: Caldera Resource Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Type C: Caldera Resource Dictionary.png Type C: Caldera Resource: No definition has been...

  2. Micromolding of a Highly Fluorescent Reticular Coordination Polymer: Solvent-Mediated Reconfigurable Polymerization in a Soft Lithographic Mold

    SciTech Connect (OSTI)

    Y You; H Yang; J Chung; J Kim; Y Jung; S Park

    2011-12-31

    Coordination polymerization of pyridine-based ligands and zinc or silver ions was controlled by soft lithographic micromolding in capillaries. The polymer patterns that are produced are highly fluorescent and supramolecularly structured.

  3. Structural basis for bathochromic shift of fluorescence in far-red fluorescent proteins eqFP650 and eqFP670

    SciTech Connect (OSTI)

    Pletnev, Sergei; Pletneva, Nadya V.; Souslova, Ekaterina A.; Wlodawer, Alexander; Dauter, Zbigniew; Pletnev, Vladimir

    2012-09-01

    The crystal structures of the far-red fluorescent proteins eqFP650 and eqFP670 have been solved at 1.8 and 1.6 Å resolution, respectively. This permitted identification of the structural elements responsible for the bathochromic shift in both considered far-red fluorescent proteins. The crystal structures of the far-red fluorescent proteins (FPs) eqFP650 (λ{sub ex}{sup max}/λ{sub em}{sup max} 592/650 nm) and eqFP670 (λ{sub ex}{sup max}/λ{sub em}{sup max} 605/670 nm), the successors of the far-red FP Katushka (λ{sub ex}{sup max}/λ{sub em}{sup max} 588/635 nm), have been determined at 1.8 and 1.6 Å resolution, respectively. An examination of the structures demonstrated that there are two groups of changes responsible for the bathochromic shift of excitation/emission bands of these proteins relative to their predecessor. The first group of changes resulted in an increase of hydrophilicity at the acylimine site of the chromophore due to the presence of one and three water molecules in eqFP650 and eqFP670, respectively. These water molecules provide connection of the chromophore with the protein scaffold via hydrogen bonds causing an ∼15 nm bathochromic shift of the eqFP650 and eqFP670 emission bands. The second group of changes observed in eqFP670 arises from substitution of both Ser143 and Ser158 by asparagines. Asn143 and Asn158 of eqFP670 are hydrogen bonded with each other, as well as with the protein scaffold and with the p-hydroxyphenyl group of the chromophore, resulting in an additional ∼20 nm bathochromic shift of the eqFP670 emission band as compared to eqFP650. The role of the observed structural changes was verified by mutagenesis.

  4. Wheel-type magnetic refrigerator

    DOE Patents [OSTI]

    Barclay, J.A.

    1983-10-11

    The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load. 7 figs.

  5. Wheel-type magnetic refrigerator

    DOE Patents [OSTI]

    Barclay, J.A.

    1982-01-20

    The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load.

  6. Wheel-type magnetic refrigerator

    DOE Patents [OSTI]

    Barclay, John A.

    1983-01-01

    The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load.

  7. Flame front imaging in an internal-combustion engine simulator by laser-induced fluorescence of acetaldehyde

    SciTech Connect (OSTI)

    Arnold, A.; Becker, H.; Suntz, R.; Monkhouse, P.; Wolfrum, J. ); Maly, R.; Pfister, W. )

    1990-08-01

    Acetaldehyde has been used as a fluorescent dopant for two-dimensional imaging of the flame front in an internal-combustion-engine simulator. The molecule was excited with a XeCl-laser-light sheet at 308 nm, and broadband fluorescence centered at 400 nm was detected. In this way, the flame front could be marked by mapping regions of unburned gas. Also, the intake process into the engine could be followed.

  8. CALiPER Report 21.2. Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers

    SciTech Connect (OSTI)

    2014-05-01

    Although lensed troffers are numerous, there are many other types of optical systems as well. This report looks at the performance of three linear (T8) LED lamps—chosen primarily based on their luminous intensity distributions (narrow, medium, and wide beam angles)—as well as a benchmark fluorescent lamp in five different troffer types. Also included are the results of a subjective evaluation. Results show that linear (T8) LED lamps can improve luminaire efficiency in K12-lensed and parabolic-louvered troffers, effect little change in volumetric and high-performance diffuse-lensed type luminaires, but reduce efficiency in recessed indirect troffers. These changes can be accompanied by visual appearance and visual comfort consequences, especially when LED lamps with clear lenses and narrow distributions are installed. Linear (T8) LED lamps with diffuse apertures exhibited wider beam angles, performed more similarly to fluorescent lamps, and received better ratings from observers. Guidance is provided on which luminaires are the best candidates for retrofitting with linear (T8) LED lamps.

  9. High resolution x-ray fluorescence spectroscopy - a new technique for site- and spin-selectivity

    SciTech Connect (OSTI)

    Wang, Xin

    1996-12-01

    X-ray spectroscopy has long been used to elucidate electronic and structural information of molecules. One of the weaknesses of x-ray absorption is its sensitivity to all of the atoms of a particular element in a sample. Through out this thesis, a new technique for enhancing the site- and spin-selectivity of the x-ray absorption has been developed. By high resolution fluorescence detection, the chemical sensitivity of K emission spectra can be used to identify oxidation and spin states; it can also be used to facilitate site-selective X-ray Absorption Near Edge Structure (XANES) and site-selective Extended X-ray Absorption Fine Structure (EXAFS). The spin polarization in K fluorescence could be used to generate spin selective XANES or spin-polarized EXAFS, which provides a new measure of the spin density, or the nature of magnetic neighboring atoms. Finally, dramatic line-sharpening effects by the combination of absorption and emission processes allow observation of structure that is normally unobservable. All these unique characters can enormously simplify a complex x-ray spectrum. Applications of this novel technique have generated information from various transition-metal model compounds to metalloproteins. The absorption and emission spectra by high resolution fluorescence detection are interdependent. The ligand field multiplet model has been used for the analysis of K{alpha} and K{beta} emission spectra. First demonstration on different chemical states of Fe compounds has shown the applicability of site selectivity and spin polarization. Different interatomic distances of the same element in different chemical forms have been detected using site-selective EXAFS.

  10. Fluorescence imaging of viscous materials in the ultraviolet-visible wavelength range

    SciTech Connect (OSTI)

    Murr, Patrik J. Rauscher, Markus S.; Tremmel, Anton; Schardt, Michael; Koch, Alexander W.

    2014-08-15

    This paper presents an approach of an innovative measurement principle for the quality control of viscous materials during a manufacturing process based on fluorescence imaging. The main contribution to the state of the art provided by this measurement system is that three equal fluorescence images of a static or moving viscous object are available in different optical paths. The independent images are obtained by two beam splitters which are connected in series. Based on these images, it is possible to evaluate each image separately. In our case, three optical bandpass filters with different center wavelengths of 405 nm, 420 nm, and 440 nm were used to filter the separate fluorescence images. The developed system is useable for the detection of impurities in the micrometer range. Further, incorrect mixing ratios of particular components and wrong single components in the viscous materials can be detected with the setup. Moreover, it is possible to realize static and dynamic measurements. In this case the maximum speed of the objects was 0.2 m/s for the dynamic measurements. Advantages of this measurement setup are the universality due to the use of optical standard components, the small dimension and the opportunity to integrate it easily into ongoing processes. In addition, the measurement system works on a non-contact basis. Thus, the expense for maintenance is at a very low level compared to currently available measurement setups for the investigated application. Furthermore, the setup provides for the first time a simultaneous analysis of more than one component and the detection of impurities concerning their nature and size in a manufacturing process.

  11. Optimizing detector geometry for trace element mapping by X-ray fluorescence

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Sun, Yue; Gleber, Sophie -Charlotte; Jacobsen, Chris; Kirz, Janos; Vogt, Stefan

    2015-01-01

    We report that trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral responsemore » of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. In conclusion, we conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.« less

  12. Methods and kits for nucleic acid analysis using fluorescence resonance energy transfer

    DOE Patents [OSTI]

    Kwok, Pui-Yan; Chen, Xiangning

    1999-01-01

    A method for detecting the presence of a target nucleotide or sequence of nucleotides in a nucleic acid is disclosed. The method is comprised of forming an oligonucleotide labeled with two fluorophores on the nucleic acid target site. The doubly labeled oligonucleotide is formed by addition of a singly labeled dideoxynucleoside triphosphate to a singly labeled polynucleotide or by ligation of two singly labeled polynucleotides. Detection of fluorescence resonance energy transfer upon denaturation indicates the presence of the target. Kits are also provided. The method is particularly applicable to genotyping.

  13. Impurity detection in the APEX tokamak by in-situ doppler shift laser fluorescence spectroscopy

    SciTech Connect (OSTI)

    Pellin, M.J.; Young, C.E.; Gruen, D.M.; Norem, J.H.

    1981-01-01

    Laser fluorescence spectroscopy (LFS) is a promising impurity atoms generated from surfaces exposed to fusion plasmas. Here the first continuous wave laser fluorescene measurement of impurities generated during a single tokamak pulse is reported. The results point out the promise of LFS as an essentially real time, in-situ diagnostic allowing a detailed comparison of impurity generation and transport with Tokamak parameters and operating conditions. Results presented will include the Zr-atom density and velocity distribution produced from a Zr-metal target during an Apex Tokamak discharge.

  14. Contemporary research with nuclear resonance fluorescence at the S-DALINAC

    SciTech Connect (OSTI)

    Zweidinger, M.; Beck, T.; Beller, J.; Gayer, U.; Mertes, L.; Pai, H.; Pietralla, N.; Ries, P.; Romig, C.; Werner, V.

    2015-02-24

    In the last decades many nuclear resonance fluorescence experiments aiming for low-lying dipole excitations were performed at the Darmstadt High Intensity Photon Setup at S-DALINAC facility. On the electric dipole side, quadrupole-octupole coupled states and the Pygmy Dipole Resonance are of particular interest. On the magnetic dipole side, the so-called scissors mode is in the focus of interest. Furthermore, using the method of resonant self absorption, the decay behavior of J{sup π} = 1{sup −} states was investigated in {sup 140}Ce.

  15. Characterization of supernumerary ring marker chromosomes by fluorescence in situ hybridization (FISH)

    SciTech Connect (OSTI)

    Blennow, E.; Nordenskjoeld, M. ); Asadi, E. ); Anneren, G.; Berggren, E.; Nordenskjoeld, M.

    1993-08-01

    Five cases with small supernumerary ring chromosomes are characterized at the molecular level. Routine chromosome banding analysis was insufficient for identification of the ring chromosomes, and none of them was DA/DAPI positive. Fluorescence in situ hybridization utilizing repetitive centromeric probes for all chromosomes has determined that one of these five ring chromosomes originates in each of chromosomes 4, 7, 8, 9, and 20. Chromosome painting with chromosome-specific libraries has confirmed this and excluded the involvement of additional chromosomes in the rearrangements. 30 refs., 3 figs., 2 tabs.

  16. Simulations of fluorescence solvatochromism in substituted PPV oligomers from excited state molecular dynamics with implicit solvent

    SciTech Connect (OSTI)

    Bjorgaard, J. A.; Nelson, T.; Kalinin, K.; Kuzmenko, V.; Velizhanin, K. A.; Tretiak, S.

    2015-04-28

    In this study, an efficient method of treating solvent effects in excited state molecular dynamics (ESMD) is implemented and tested by exploring the solvatochromic effects in substituted p-phenylene vinylene oligomers. A continuum solvent model is used which has very little computational overhead. This allows simulations of ESMD with solvent effects on the scale of hundreds of picoseconds for systems of up to hundreds of atoms. At these time scales, solvatochromic shifts in fluoresence spectra can be described. Solvatochromic shifts in absorption and fluorescence spectra from ESMD are compared with time-dependent density functional theory calculations and experiments.

  17. Surface extended x-ray absorption fine structure of low-Z absorbates using fluorescence detection

    SciTech Connect (OSTI)

    Stoehr, J.; Kollin, E.B.; Fischer, D.A.; Hastings, J.B.; Zaera, F.; Sette, F.

    1985-05-01

    Comparison of x-ray fluorescence yield (FY) and electron yield surface extended x-ray absorption fine structure spectra above the S K-edge for c(2 x 2) S on Ni(100) reveals an order of magnitude higher sensitivity of the FY technique. Using FY detection, thiophene (C/sub 4/H/sub 4/S) chemisorption on Ni(100) is studied with S coverages down to 0.08 monolayer. The molecule dissociates at temperatures as low as 100K by interaction with fourfold hollow Ni sites. Blocking of these sites by oxygen leaves the molecule intact.

  18. Compact Fluorescent Lighting in America: Lessons Learned on the Way to Market

    SciTech Connect (OSTI)

    Sandahl, Linda J.; Gilbride, Theresa L.; Ledbetter, Marc R.; Steward, Heidi E.; Calwell, Chris

    2006-05-22

    This report describes the history of compact fluorescent lamps (CFLs) in America. CFLs were introduced in the 1970s; however, it has taken more than 20 years for them to gain widespread recognition in the U.S. residential lighting market. This report reviews the development of CFLs, efforts to increase market acceptance of them, and barriers to that acceptance. Lessons to be learned from this study of CFLs are identified in hopes of assisting future market introduction efforts for other promising energy-efficient technologies. This report was prepared by the Pacific Northwest National Laboratory for the U.S. Department of Energy’s Office of Building Technologies, Emerging Technologies Program.

  19. Fluorescence method for enzyme analysis which couples aromatic amines with aromatic aldehydes

    DOE Patents [OSTI]

    Smith, Robert E. [557 Escondido Cir., Livermore, CA 94550; Dolbeare, Frank A. [5178 Diane La., Livermore, CA 94550

    1980-10-21

    Analysis of proteinases is accomplished using conventional amino acid containing aromatic amine substrates. Aromatic amines such as 4-methoxy-2-naphthylamine (4M2NA), 2-naphthylamine, aminoisophthalic acid dimethyl ester, p-nitroaniline, 4-methoxy-1-aminofluorene and coumarin derivatives resulting from enzymatic hydrolysis of the substrate couples with aromatic aldehydes such as 5-nitrosalicylaldehyde (5-NSA), benzaldehyde and p-nitrobenzaldehyde to produce Schiff-base complexes which are water insoluble. Certain Schiff-base complexes produce a shift from blue to orange-red (visible) fluorescence. Such complexes are useful in the assay of enzymes.

  20. Fluorescence method for enzyme analysis which couples aromatic amines with aromatic aldehydes

    DOE Patents [OSTI]

    Smith, Robert E.; Dolbeare, Frank A.

    1979-01-01

    Analysis of proteinases is accomplished using conventional amino acid containing aromatic amine substrates. Aromatic amines such as 4-methoxy-2-naphthylamine (4M2NA), 2-naphthylamine, aminoisophthalic acid dimethyl ester, p-nitroaniline, 5-methoxy-1-aminofluorene and coumarin derivatives resulting from enzymatic hydrolysis of the substrate couples with aromatic aldehydes such as 5-nitrosalicylaldehyde (5-NSA), benzaldehyde and p-nitrobenzaldehyde to produce Schiff-base complexes which are water insoluble. Certain Schiff-base complexes produce a shift from blue to orange-red (visible) fluorescence. Such complexes are useful in the assay of enzymes.

  1. High-efficiency white organic light-emitting diodes using thermally activated delayed fluorescence

    SciTech Connect (OSTI)

    Nishide, Jun-ichi; Hiraga, Yasuhide; Nakanotani, Hajime; Adachi, Chihaya

    2014-06-09

    White organic light-emitting diodes (WOLEDs) have attracted much attention recently, aimed for next-generation lighting sources because of their high potential to realize high electroluminescence efficiency, flexibility, and low-cost manufacture. Here, we demonstrate high-efficiency WOLED using red, green, and blue thermally activated delayed fluorescence materials as emissive dopants to generate white electroluminescence. The WOLED has a maximum external quantum efficiency of over 17% with Commission Internationale de l'Eclairage coordinates of (0.30, 0.38).

  2. Investigations regarding the wet decontamination of fluorescent lamp waste using iodine in potassium iodide solutions

    SciTech Connect (OSTI)

    Tunsu, Cristian Ekberg, Christian; Foreman, Mark; Retegan, Teodora

    2015-02-15

    Highlights: • A wet-based decontamination process for fluorescent lamp waste is proposed. • Mercury can be leached using iodine in potassium iodide solution. • The efficiency of the process increases with an increase in leachant concentration. • Selective leaching of mercury from rare earth elements is achieved. • Mercury is furthered recovered using ion exchange, reduction or solvent extraction. - Abstract: With the rising popularity of fluorescent lighting, simple and efficient methods for the decontamination of discarded lamps are needed. Due to their mercury content end-of-life fluorescent lamps are classified as hazardous waste, requiring special treatment for disposal. A simple wet-based decontamination process is required, especially for streams where thermal desorption, a commonly used but energy demanding method, cannot be applied. In this study the potential of a wet-based process using iodine in potassium iodide solution was studied for the recovery of mercury from fluorescent lamp waste. The influence of the leaching agent’s concentration and solid/liquid ratio on the decontamination efficiency was investigated. The leaching behaviour of mercury was studied over time, as well as its recovery from the obtained leachates by means of anion exchange, reduction, and solvent extraction. Dissolution of more than 90% of the contained mercury was achieved using 0.025/0.05 M I{sub 2}/KI solution at 21 °C for two hours. The efficiency of the process increased with an increase in leachant concentration. 97.3 ± 0.6% of the mercury contained was dissolved at 21 °C, in two hours, using a 0.25/0.5 M I{sub 2}/KI solution and a solid to liquid ratio of 10% w/v. Iodine and mercury can be efficiently removed from the leachates using Dowex 1X8 anion exchange resin or reducing agents such as sodium hydrosulphite, allowing the disposal of the obtained solution as non-hazardous industrial wastewater. The extractant CyMe{sub 4}BTBP showed good removal of mercury

  3. Surface fluorescence method can identify potential oil pay zones in Permian Basin

    SciTech Connect (OSTI)

    Burrows, R. ); Calhoun, G.G.

    1992-09-28

    This paper points out a direct relationship between the fluorescence signature between the oil produced from a well and that found in the soils overlying that oil accumulation. Under the right conditions, an operator can know before drilling which of the potential pays in its prospect is trapped and microseeping to the surface. Some have suggested that half the oil that has been produced was found using visible oil seeps as indictions of traps. With those obvious opportunities on production, only more subtle microseeps remain. Instruments sensitive enough to measure these miniscule amounts of aromatic hydrocarbons have only recently become available.

  4. Quantitative characterization of a nonreacting, supersonic combustor flowfield using unified, laser-induced iodine fluorescence

    SciTech Connect (OSTI)

    Fletcher, D.G.; McDaniel, J.C.

    1989-01-01

    A calibrated, nonintrusive optical technique, laser-induced iodine fluorescence (LIIF) was used to quantify the steady, compressible flowfield of a nonreacting, supersonic combustor. The combustor was configured with single and staged, transverse-air injection into a supersonic-air freestream behind a rearward-facing step. Pressure, temperature, two-velocity components, and injectant mole fraction were measured with high spatial resolution in the three-dimensional flowfields. These experimental results provide a benchmark set of data for validation of computational fluid dynamic (CFD) codes being developed to model supersonic combustor flowfields. 8 refs.

  5. Fluorescence method for enzyme analysis which couples aromatic amines with aromatic aldehydes

    DOE Patents [OSTI]

    Smith, R.E.; Dolbeare, F.A.

    1980-10-21

    Analysis of proteinases is accomplished using conventional amino acid containing aromatic amine substrates. Aromatic amines such as 4-methoxy-2-naphthylamine (4M2NA), 2-naphthylamine, aminoisophthalic acid dimethyl ester, p-nitroaniline, 4-methoxy-1-aminofluorene and coumarin derivatives resulting from enzymatic hydrolysis of the substrate couples with aromatic aldehydes such as 5-nitrosalicylaldehyde (5-NSA), benzaldehyde and p-nitrobenzaldehyde to produce Schiff-base complexes which are water insoluble. Certain Schiff-base complexes produce a shift from blue to orange-red (visible) fluorescence. Such complexes are useful in the assay of enzymes. No Drawings

  6. Type:Epoch | Open Energy Information

    Open Energy Info (EERE)

    Type:Epoch Jump to: navigation, search An Epoch is a measurement for a given length of time. The use of type pages has been deprecated. Please set properties to Quantity and use...

  7. Archive Reference Buildings by Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  8. Property:Geothermal/Type | Open Energy Information

    Open Energy Info (EERE)

    to: navigation, search This is a property of type String. Pages using the property "GeothermalType" Showing 25 pages using this property. (previous 25) (next 25) 4 4 UR Guest...

  9. Method and apparatus for enhanced evanescent fluorescence and color filtering using a high refractive index thin film coating

    DOE Patents [OSTI]

    Kao, Hung Pin; Schoeniger, Joseph; Yang, Nancy

    2001-01-01

    A technique for increasing the excitation and collection of evanescent fluorescence radiation emanating from a fiber optic sensor having a high refractive index (n.sub.r), dielectric thin film coating has been disclosed and described. The invention comprises a clad optical fiber core whose cladding is removed on a distal end, the distal end coated with a thin, non-porous, titanium dioxide sol-gel coating. It has been shown that such a fiber will exhibit increased fluorescence coupling due in part by 1) increasing the intensity of the evanescent field at the fiber core surface by a constructive interference effect on the propagating light, and 2) increasing the depth of penetration of the field in the sample. The interference effect created by the thin film imposes a wavelength dependence on the collection of the fluorescence and also suggests a novel application of thin films for color filtering as well as increasing collected fluorescence in fiber sensors. Collected fluorescence radiation increased by up to 6-fold over that of a bare fused silica fiber having a numerical aperture (N.A.) of O.6.

  10. Crystal of GTP Cyclohydrolase Type IB

    DOE Patents [OSTI]

    Swairjo, Manal A.; Iwata-Reuyl, Dirk; de Crecy-Lagard, Valerie

    2012-12-11

    This invention relates to a novel, bacterial GTP Cyclohydrolase Type IB enzyme, and the crystal structure thereof.

  11. Types of Homes | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Homes Types of Homes Manufactured homes are one type of home that may require special considerations for energy efficiency and renewable energy technologies. | Photo courtesy of Florida Solar Energy Center. Manufactured homes are one type of home that may require special considerations for energy efficiency and renewable energy technologies. | Photo courtesy of Florida Solar Energy Center. Some types of homes may require different considerations when it comes to energy efficiency. You may be

  12. Type B Accident Investigation, Subcontractor Employee Personal...

    Office of Environmental Management (EM)

    Investigation, Subcontractor Employee Personal Protective Equipment Ignition Incident on ... Type B Accident Investigation, Subcontractor Employee Personal Protective Equipment ...

  13. Fluorescent growth bands in irradiated-bitumen nodules: Evidence of episodic hydrocarbon migration

    SciTech Connect (OSTI)

    Rasmussen, B.

    1997-01-01

    Minute rims of solid bitumen ({approximately}40-50 {mu}m thick) surround detrital radioactive grains in the Permian-Triassic sandstones and Arranoo Member of the Kockatea Shale from the northern Perth basin, Australia. The bitumen formed as Th- and U-bearing minerals (monazite, xenotime, zircon, thorite) irradiated and immobilized fluid hydrocarbons coming within range of alpha-particle emissions. using transmitted light and scanning electron microscopy and rims appear compositionally homogeneous, but under blue/violet epifluorescent illumination the bitumen displays complex concentric and contorted banding. These fluorescent textures indicate that multiple influxes of hydrocarbons passed through the reservoir sandstones. Following radiation-induced immobilization of hydrocarbons from the first oil influx, the bitumen nodules grew through a process of swelling and expansion outward form the mineral core during subsequent oil influxes, producing graded fluorescent growth bands. Oil droplets and lamellae also were adsorbed onto the outer portion of the nodules. Such bitumen nodules are a new and potentially important source of data for understanding the movement of hydrocarbons in sedimentary basins, specifically for identifying hydrocarbon pathways, the number of discrete hydrocarbon pulses, and the relative timing of oil migration.

  14. Dual x-ray fluorescence spectrometer and method for fluid analysis

    DOE Patents [OSTI]

    Wilson, Bary W.; Shepard, Chester L.

    2005-02-22

    Disclosed are an X-ray fluorescence (SRF) spectrometer and method for on-site and in-line determination of contaminant elements in lubricating oils and in fuel oils on board a marine vessel. An XRF source block 13 contains two radionuclide sources 16, 17 (e.g. Cd 109 and Fe 55), each oriented 180 degrees from the other to excite separate targets. The Cd 109 source 16 excites sample lube oil flowing through a low molecular weight sample line 18. The Fe 55 source 17 excites fuel oil manually presented to the source beam inside a low molecular weight vial 26 or other container. Two separate detectors A and B are arranged to detect the fluorescent x-rays from the targets, photons from the analyte atoms in the lube oil for example, and sulfur identifying x-rays from bunker fuel oil for example. The system allows both automated in-line and manual on-site analysis using one set of signal processing and multi-channel analyzer electronics 34, 37 as well as one computer 39 and user interface 43.

  15. Raman and fluorescence characteristics of resonant inelastic X-ray scattering from doped superconducting cuprates

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Huang, H. Y.; Jia, C. J.; Chen, Z. Y.; Wohlfeld, K.; Moritz, B.; Devereaux, T. P.; Wu, W. B.; Okamoto, J.; Lee, W. S.; Hashimoto, M.; et al

    2016-01-22

    Measurements of spin excitations are essential for an understanding of spin-mediated pairing for superconductivity; and resonant inelastic X-ray scattering (RIXS) provides a considerable opportunity to probe high-energy spin excitations. However, whether RIXS correctly measures the collective spin excitations of doped superconducting cuprates remains under debate. Here we demonstrate distinct Raman- and fluorescence-like RIXS excitations of Bi1.5Pb0.6Sr1.54CaCu2O8+δ. Combining photon-energy and momentum dependent RIXS measurements with theoretical calculations using exact diagonalization provides conclusive evidence that the Raman-like RIXS excitations correspond to collective spin excitations, which are magnons in the undoped Mott insulators and evolve into paramagnons in doped superconducting compounds. In contrast,more » the fluorescence-like shifts are due primarily to the continuum of particle-hole excitations in the charge channel. Our results show that under the proper experimental conditions RIXS indeed can be used to probe paramagnons in doped high-Tc cuprate superconductors.« less

  16. OH-Planar Fluorescence Measurements of Pressurized, Hydrogen Premixed Flames in the SimVal Combustor

    SciTech Connect (OSTI)

    Strakey, P.A.; Woodruff, S.D.; Williams, T.C.; Schefer, R.W.

    2008-07-01

    Planar laser-induced fluorescence measurements of the hydroxyl radical in lean, premixed natural gas flames augmented with hydrogen are presented. The experiments were conducted in the Simulation Validation combustor at the National Energy Technology Laboratory at operating pressures from 1 to 8 atmospheres. The data, which were collected in a combustor with well-controlled boundary conditions, are intended to be used for validating computational fluid dynamics models under conditions directly relevant to land-based gas turbine engines. The images, which show significant effects of hydrogen on local flame quenching, are discussed in terms of a turbulent premixed combustion regime and nondimensional parameters such as Karlovitz number. Pressure was found to thin the OH region, but only had a secondary effect on overall flame shape compared with the effects of hydrogen addition, which was found to decrease local quenching and shorten the turbulent flame brush. A method to process the individual images based on local gradients of fluorescence intensity is proposed, and results are presented. Finally, the results of several large eddy simulations are presented and compared with the experimental data in an effort to understand the issues related to model validation, especially for simulations that do not include OH as an intermediate species.

  17. Isotopic imaging via nuclear resonance fluorescence with laser-based Thomson radiation

    DOE Patents [OSTI]

    Barty, Christopher P. J.; Hartemann, Frederic V.; McNabb, Dennis P.; Pruet, Jason A.

    2009-07-21

    The present invention utilizes novel laser-based, high-brightness, high-spatial-resolution, pencil-beam sources of spectrally pure hard x-ray and gamma-ray radiation to induce resonant scattering in specific nuclei, i.e., nuclear resonance fluorescence. By monitoring such fluorescence as a function of beam position, it is possible to image in either two dimensions or three dimensions, the position and concentration of individual isotopes in a specific material configuration. Such methods of the present invention material identification, spatial resolution of material location and ability to locate and identify materials shielded by other materials, such as, for example, behind a lead wall. The foundation of the present invention is the generation of quasimonochromatic high-energy x-ray (100's of keV) and gamma-ray (greater than about 1 MeV) radiation via the collision of intense laser pulses from relativistic electrons. Such a process as utilized herein, i.e., Thomson scattering or inverse-Compton scattering, produces beams having diameters from about 1 micron to about 100 microns of high-energy photons with a bandwidth of .DELTA.E/E of approximately 10E.sup.-3.

  18. Synthesis and evaluation of radioactive and fluorescent residualizing labels for identifying sites of plasma protein catabolism

    SciTech Connect (OSTI)

    Maxwell, J.L.; Baynes, J.W.; Thorpe, S.R.

    1986-05-01

    Inulin and lactose were each coupled to tyramine by reductive amination with NaBH/sub 3/CN and the tyramine then labeled with /sup 125/I. Dilactitol-/sup 125/I-tyramine (DLT) and inulin-/sup 125/I-tyramine (InTn) were coupled by reductive amination and cyanuric chloride, respectively, to asialofetuin (ASF), fetuin and rat serum albumin (RSA). Attachment of either label had no effect on the circulating half-lives of the proteins. Radioactivity from labeled ASF was recovered in rat liver (> 90%) by 1 h post-injection and remained in liver with half-lives of 2 and 6 days, respectively, for the DLT and InTn labels. Whole body recoveries of radioactivity from DLT- and InTn labels. Whole body recoveries of radioactivity from DLT- and InTn-labeled RSA were 5 and 6.5 days, respectively, again indicating that the larger glycoconjugate label residualized more efficiently in cells following protein degradation. (Lactitol)/sub 2/-N-CH/sub 2/-CH/sub 2/-NH-fluroescein (DLF) was also coupled to ASF by reductive amination and recovered quantitatively in liver at 1 h post-injection. Native ASF was an effective competitor for clearance of DLF-ASF from the circulation. Fluorescent degradation products were retained in liver with a half-life of 1.2 days. Residualizing fluorescent labels should be useful for identification and sorting of cells active in the degradation of plasma proteins.

  19. Recovery of aluminium, nickel-copper alloys and salts from spent fluorescent lamps

    SciTech Connect (OSTI)

    Rabah, Mahmoud A

    2004-07-01

    This study explores a combined pyro-hydrometallurgical method to recover pure aluminium, nickel-copper alloy(s), and some valuable salts from spent fluorescent lamps (SFLs). It also examines the safe recycling of clean glass tubes for the fluorescent lamp industry. Spent lamps were decapped under water containing 35% acetone to achieve safe capture of mercury vapour. Cleaned glass tubes, if broken, were cut using a rotating diamond disc to a standard shorter length. Aluminium and copper-nickel alloys in the separated metallic parts were recovered using suitable flux to decrease metal losses going to slag. Operation variables affecting the quality of the products and the extent of recovery with the suggested method were investigated. Results revealed that total loss in the glass tube recycling operation was 2% of the SFLs. Pure aluminium meeting standard specification DIN 1712 was recovered by melting at 800 deg. C under sodium chloride/carbon flux for 20 min. Standard nickel-copper alloys with less than 0.1% tin were prepared by melting at 1250 deg. C using a sodium borate/carbon flux. De-tinning of the molten nickel-copper alloy was carried out using oxygen gas. Tin in the slag as oxide was recovered by reduction using carbon or hydrogen gas at 650-700 deg. C. Different valuable chloride salts were also obtained in good quality. Further research is recommended on the thermodynamics of nickel-copper recovery, yttrium and europium recovery, and process economics.

  20. Crystal structure of phototoxic orange fluorescent proteins with α tryptophan-based chromophore

    SciTech Connect (OSTI)

    Pletneva, Nadya V.; Pletnev, Vladimir Z.; Sarkisyan, Karen S.; Gorbachev, Dmitry A.; Egorov, Evgeny S.; Mishin, Alexander S.; Lukyanov, Konstantin A.; Dauter, Zbigniew; Pletnev, Sergei

    2015-12-23

    Phototoxic fluorescent proteins represent a sparse group of genetically encoded photosensitizers that could be used for precise light-induced inactivation of target proteins, DNA damage, and cell killing. Only two such GFP-based fluorescent proteins (FPs), KillerRed and its monomeric variant SuperNova, were described up to date. We present a crystallographic study of their two orange successors, dimeric KillerOrange and monomeric mKiller-Orange, at 1.81 and 1.57 Å resolution, respectively. They are the first orange-emitting protein photosensitizers with a tryptophan-based chromophore (Gln65-Trp66-Gly67). Same as their red progenitors, both orange photosensitizers have a water-filled channel connecting the chromophore to the β-barrel exterior and enabling transport of ROS. In both proteins, Trp66 of the chromophore adopts an unusual trans-cis conformation stabilized by H-bond with the nearby Gln159. This trans-cis conformation along with the water channel was shown to be a key structural feature providing bright orange emission and phototoxicity of both examined orange photosensitizers.

  1. Crystal structure of phototoxic orange fluorescent proteins with α tryptophan-based chromophore

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Pletneva, Nadya V.; Pletnev, Vladimir Z.; Sarkisyan, Karen S.; Gorbachev, Dmitry A.; Egorov, Evgeny S.; Mishin, Alexander S.; Lukyanov, Konstantin A.; Dauter, Zbigniew; Pletnev, Sergei

    2015-12-23

    Phototoxic fluorescent proteins represent a sparse group of genetically encoded photosensitizers that could be used for precise light-induced inactivation of target proteins, DNA damage, and cell killing. Only two such GFP-based fluorescent proteins (FPs), KillerRed and its monomeric variant SuperNova, were described up to date. We present a crystallographic study of their two orange successors, dimeric KillerOrange and monomeric mKiller-Orange, at 1.81 and 1.57 Å resolution, respectively. They are the first orange-emitting protein photosensitizers with a tryptophan-based chromophore (Gln65-Trp66-Gly67). Same as their red progenitors, both orange photosensitizers have a water-filled channel connecting the chromophore to the β-barrel exterior and enablingmore » transport of ROS. In both proteins, Trp66 of the chromophore adopts an unusual trans-cis conformation stabilized by H-bond with the nearby Gln159. This trans-cis conformation along with the water channel was shown to be a key structural feature providing bright orange emission and phototoxicity of both examined orange photosensitizers.« less

  2. Measurement of plutonium in spent nuclear fuel by self-induced x-ray fluorescence

    SciTech Connect (OSTI)

    Hoover, Andrew S; Rudy, Cliff R; Tobin, Steve J; Charlton, William S; Stafford, A; Strohmeyer, D; Saavadra, S

    2009-01-01

    Direct measurement of the plutonium content in spent nuclear fuel is a challenging problem in non-destructive assay. The very high gamma-ray flux from fission product isotopes overwhelms the weaker gamma-ray emissions from plutonium and uranium, making passive gamma-ray measurements impossible. However, the intense fission product radiation is effective at exciting plutonium and uranium atoms, resulting in subsequent fluorescence X-ray emission. K-shell X-rays in the 100 keV energy range can escape the fuel and cladding, providing a direct signal from uranium and plutonium that can be measured with a standard germanium detector. The measured plutonium to uranium elemental ratio can be used to compute the plutonium content of the fuel. The technique can potentially provide a passive, non-destructive assay tool for determining plutonium content in spent fuel. In this paper, we discuss recent non-destructive measurements of plutonium X-ray fluorescence (XRF) signatures from pressurized water reactor spent fuel rods. We also discuss how emerging new technologies, like very high energy resolution microcalorimeter detectors, might be applied to XRF measurements.

  3. Nonflame, source-induced sulfur fluorescence detector for sulfur-containing compounds

    SciTech Connect (OSTI)

    Gage, D.R.; Farwell, S.O.

    1980-12-01

    Results of some preliminary investigations of the fluorescence spectra of S/sub 2/ and the non-flame production of S/sub 2/ from sulfur-containing molecules are reported. Passage of the gas to be analyzed through a catalyst-oven containing a plug of NiO/sub 2//Al/sub 2/O/sub 3/ catalyst containing 10 wt% NiO/sub 2/ and heated to 400/sup 0/C resulted in conversion of H/sub 2/S to S/sub 2/ and elemental sulfur. The S/sub 2/ was detected by measurement of its fluorescence bands at 260 and 310nm, and elemental sulfur condensed on the cool parts of the apparatus. However, determination of sulfur-content of gas mixtures with the apparatus described herein were not as repeatable as desired, and the work is being continued on various facets of the non-flame system with work being directed toward the evaluation of different catalysts, catalyst temperature, design of a smaller detector geometry utilizing a pulsed-light excitation source, a windowless cell, and optical filters instead of monochromators to select the S/sub 2/ excitation and emission wavelengths. (BLM)

  4. Characterization of a new photo-fluorescent film dosimeter for high-radiation dose applications

    SciTech Connect (OSTI)

    Murphy, Mark K. ); Miller, Steven D. ); Kovacs, Andras; Mclaughlin, William L.; Slezsak, Istvan

    2001-12-01

    Characterization studies on one of the first versions of the Sunna fluorescent dosimeter have been published by Kovacs and McLaughlin. This present study describes testing results of a newer version of the dosimeter (Model and 61543;, batch 0399-20). This dosimeter is a 1-cm by 3-cm polymeric film of 0.5 mm thickness that emits a green fluorescence component at intensities almost linear with dose. The manufacturing method (injection molding) allows potential batch sizes on the order of a million while maintaining a signal precision on the order of+/- 1%. Studies include dose response, dose rate dependence, energy dependence, post-irradiation stability, environmental effects, and variation of response within a batch. Data for both food irradiation and sterilization dose levels were obtained. The results indicate that the green signal (0.3-200 kGy) works well for food irradiation dose levels, especially in refrigerated facilities that maintain tight temperature control. The green signal also works well in sterilization facilities because its irradiation temperature coefficient above room temperature is minimal at sterilization doses. If the user requires readout results in less than 22 hours after room temperature irradiation, the user can either calibrate for a specific post-irradiation readout time(s) or simply heat the dosimeters in a small laboratory oven to quickly stabilize the signal.

  5. Filter type rotor for multistation photometer

    DOE Patents [OSTI]

    Shumate, II, Starling E.

    1977-07-12

    A filter type rotor for a multistation photometer is provided. The rotor design combines the principle of cross-flow filtration with centrifugal sedimentation so that these occur simultaneously as a first stage of processing for suspension type fluids in an analytical type instrument. The rotor is particularly useful in whole-blood analysis.

  6. Buildings Energy Data Book: 5.6 Lighting

    Buildings Energy Data Book [EERE]

    9 Typical Efficacies and Lifetimes of Lamps (1) Current Technology CRI (2) Incandescent 10 - 19 97 Halogen 14 - 20 99 Fluorescent - T5 25 - 55 52 - 75 Fluorescent - T8 35 - 87 7,500 - 20,000 52 - 90 Fluorescent - T12 35 - 92 7,500 - 20,000 50 - 92 Compact Fluorescent 40 - 70 82 Mercury Vapor 25 - 50 15 - 50 Metal Halide 65 - 70 High-Pressure Sodium 22 Low-Pressure Sodium 0 Solid State Lighting 33-97 Note(s): Source(s): 18 - 180 18,000 20 - 100 15,000 - 50,000 1) Theoretical maximum luminous

  7. Commissioning and first results of scanning type EXAFS beamline (BL-09) at INDUS-2 synchrotron source

    SciTech Connect (OSTI)

    Poswal, A. K. Agrawal, A. Yadav, A. K. Nayak, C. Basu, S. Bhattachryya, D.; Jha, S. N.; Sahoo, N. K.; Kane, S. R.; Garg, C. K.

    2014-04-24

    An Energy Scanning X-ray Absorption Fine Structure spectroscopy beamline has recently been installed and commissioned at BL-09 bending magnet port of INDUS-2 synchrotron source, Indore. The beamline uses an UHV compatible fixed exit double crystal monochromator (DCM) with two Si (111) crystals. Two grazing incidence cylindrical mirrors are also used in this beamline; the pre-mirror is used as a collimating mirror while the post mirror is used for vertical focusing and higher harmonic rejection. In this beamline it is possible to carry out EXAFS measurements both in transmission and fluorescence mode on various types of samples, using Ionization chamber detectors and solid state drift detector respectively. In this paper, results from first experiments of the Energy Scanning EXAFS beamline are presented.

  8. Comparing the host galaxies of type Ia, type II, and type Ibc supernovae

    SciTech Connect (OSTI)

    Shao, X.; Liang, Y. C.; Chen, X. Y.; Zhong, G. H.; Deng, L. C.; Zhang, B.; Shi, W. B.; Zhou, L.; Dennefeld, M.; Hammer, F.; Flores, H. E-mail: ycliang@bao.ac.cn

    2014-08-10

    We compare the host galaxies of 902 supernovae (SNe), including SNe Ia, SNe II, and SNe Ibc, which are selected by cross-matching the Asiago Supernova Catalog with the Sloan Digital Sky Survey (SDSS) Data Release 7. We selected an additional 213 galaxies by requiring the light fraction of spectral observations to be >15%, which could represent well the global properties of the galaxies. Among these 213 galaxies, 135 appear on the Baldwin-Phillips-Terlevich diagram, which allows us to compare the hosts in terms of whether they are star-forming (SF) galaxies, active galactic nuclei (AGNs; including composites, LINERs, and Seyfert 2s) or absorption-line galaxies (Absorps; i.e., their related emission lines are weak or non-existent). The diagrams related to the parameters D{sub n}(4000), H?{sub A}, stellar masses, star formation rates (SFRs), and specific SFRs for the SNe hosts show that almost all SNe II and most of the SNe Ibc occur in SF galaxies, which have a wide range of stellar masses and low D{sub n}(4000). The SNe Ia hosts as SF galaxies following similar trends. A significant fraction of SNe Ia occurs in AGNs and absorption-line galaxies, which are massive and have high D{sub n}(4000). The stellar population analysis from spectral synthesis fitting shows that the hosts of SNe II have a younger stellar population than hosts of SNe Ia. These results are compared with those of the 689 comparison galaxies where the SDSS fiber captures less than 15% of the total light. These comparison galaxies appear biased toward higher 12+log(O/H) (?0.1 dex) at a given stellar mass. Therefore, we believe the aperture effect should be kept in mind when the properties of the hosts for different types of SNe are discussed.

  9. Near-infrared fluorescence glucose sensing based on glucose/galactose-binding protein coupled to 651-Blue Oxazine

    SciTech Connect (OSTI)

    Khan, Faaizah; Pickup, John C.

    2013-08-30

    Highlights: We showed that the NIR fluorophore, 651-Blue Oxazine, is solvatochromic (polarity sensitive). Blue Oxazine was covalently attached to mutants of glucose/galactose-binding protein (GBP). Fluorescence intensity of GBP-Blue Oxazine increased with addition of glucose. Fluorescence from bead-immobilised GBP-Blue Oxazine was detectable through skin in vitro. This shows proof-of-concept for non-invasive glucose sensing using GBP-Blue Oxazine. -- Abstract: Near-infrared (NIR) fluorescent dyes that are environmentally sensitive or solvatochromic are useful tools for protein labelling in in vivo biosensor applications such as glucose monitoring in diabetes since their spectral properties are mostly independent of tissue autofluorescence and light scattering, and they offer potential for non-invasive analyte sensing. We showed that the fluorophore 651-Blue Oxazine is polarity-sensitive, with a marked reduction in NIR fluorescence on increasing solvent polarity. Mutants of glucose/galactose-binding protein (GBP) used as the glucose receptor were site-specifically and covalently labelled with Blue Oxazine using click chemistry. Mutants H152C/A213R and H152C/A213R/L238S showed fluorescence increases of 15% and 21% on addition of saturating glucose concentrations and binding constants of 6 and 25 mM respectively. Fluorescence responses to glucose were preserved when GBP-Blue Oxazine was immobilised to agarose beads, and the beads were excited by NIR light through a mouse skin preparation studied in vitro. We conclude GBP-Blue Oxazine shows proof-of-concept as a non-invasive continuous glucose sensing system.

  10. Simultaneous determination of thorium, niobium, lead, and zinc by photon-induced x-ray fluorescence of lateritic material

    SciTech Connect (OSTI)

    LaBrecque, J.J.; Adames, D.; Parker, W.C.

    1981-01-01

    A rapid method is presented for the simultaneous determinations of thorium, niobium, lead, and zinc in lateritic material from Cerro Impacto, Estado Bolivar, Venezuela. This technique uses a PDP - 11/05 processor - based photon induced x-ray fluorescence system. The total variations of approximately 5% for concentrations of approximately 1 and 10% for concentrations of approximately 0.1% were obtained with only 500 s of fluorescent time. The values obtained by this method were in agreement with values measured by conventional flame atomic absorption spectroscopy for lead and zinc. The values for thorium measured were in agreement with the reported values for the reference materials supplied by NBL.

  11. The fluorescence action spectra of some saturated hydrocarbon liquids for excitation energies above and below their ionization thresholds

    SciTech Connect (OSTI)

    Ostafin, A.E.; Lipsky, S. )

    1993-04-01

    Fluorescence action spectra have been obtained for the neat liquids, [ital cis]-decalin, [ital trans]-decalin, bicyclohexyl, cyclohexane, methylcyclohexane, isobutylcyclohexane, 2,3,4-trimethylpentane, 2,3-dimethylbutane, 3-methylhexane, 3-methylpentane, [ital n]-decane, [ital n]-dodecane, and [ital n]-pentadecane at excitation energies, [epsilon], ranging from their absorption onsets (at ca. 7 eV) to 10.3 eV. For all compounds, with the exception of [ital cis]-decalin, the fluorescence quantum yield is observed to monotonically decline with increasing [epsilon], reaching a minimum value at an energy, [epsilon][sub [ital m

  12. Temperature dependence of photoluminescence properties in a thermally activated delayed fluorescence emitter

    SciTech Connect (OSTI)

    Niwa, Akitsugu; Kobayashi, Takashi Nagase, Takashi; Naito, Hiroyoshi; Goushi, Kenichi; Adachi, Chihaya

    2014-05-26

    Using steady-state and time-resolved photoluminescence (PL) spectroscopy, we have investigated the temperature dependence of PL properties of 1,2,3,5-tetrakis(carbazol-9-yl)-4,6-dicyano-benzene (4CzIPN), which have a small energy gap between its singlet and triplet excited states and thus exhibits efficient thermally activated delayed fluorescence [H. Uoyama et al., Nature 492, 235 (2012)]. Below around 100?K, PL quantum efficiency of 4CzIPN thin films is largely suppressed and strong photoexcitation intensity dependence appears. These features can be explained by using rate equations for the densities of singlet and triplet excited states considering a triplet-triplet annihilation process.

  13. Fabrication of fluorescent composite with ultrafast aqueous synthesized high luminescent CdTe quantum dots

    SciTech Connect (OSTI)

    Zhang, Lei, E-mail: mejswu@ust.hk; Chen, Haibin, E-mail: mejswu@ust.hk, E-mail: mejswu@ust.hk; Wu, Jingshen, E-mail: mejswu@ust.hk, E-mail: mejswu@ust.hk [Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong and Fok Ying Tung Graduate School, The Hong Kong University of Science and Technology (Hong Kong); Bi, Xianghong, E-mail: takubatch@gmail.com [Fok Ying Tung Graduate School, The Hong Kong University of Science and Technology (Hong Kong)

    2014-05-15

    Without precursor preparation, inert gas protection and enormous amount of additives and reductants, CdTe quantum dots (QDs) can be rapidly synthesized with high quality. A 600 nm photoluminescence peak wavelength could be obtained within 1 hour's refluxing through minimal addition of 1,2-diaminoethane (DAE). The theoretical design for the experiments are illustrated and further proved by the characterization results with different concentrations and reagents. On the other hand, generation of CdTe QDs was found even under room temperature by applying droplet quantity of DAE. This indicates that QDs can be synthesized with simply a bottle and no enormous additives required. The QDs were mixed into the epoxy matrix through solution casting method with cetyltrimethylammonium (CTA) capping for phase transfer. The acquired epoxy based nanocomposite exhibits good transparency, compatibility and fluorescence.

  14. Real-time method and apparatus for measuring the temperature of a fluorescing phosphor

    DOE Patents [OSTI]

    Britton, Jr., Charles L.; Beshears, David L.; Simpson, Marc L.; Cates, Michael R.; Allison, Steve W.

    1999-01-01

    A method for determining the temperature of a fluorescing phosphor is provided, together with an apparatus for performing the method. The apparatus includes a photodetector for detecting light emitted by a phosphor irradiated with an excitation pulse and for converting the detected light into an electrical signal. The apparatus further includes a differentiator for differentiating the electrical signal and a zero-crossing discrimination circuit that outputs a pulse signal having a pulse width corresponding to the time period between the start of the excitation pulse and the time when the differentiated electrical signal reaches zero. The width of the output pulse signal is proportional to the decay-time constant of the phosphor.

  15. 2D laser-collision induced fluorescence in low-pressure argon discharges

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Barnat, E. V.; Weatherford, B. R.

    2015-09-25

    Development and application of laser-collision induced fluorescence (LCIF) diagnostic technique is presented for the use of interrogating argon plasma discharges. Key atomic states of argon utilized for the LCIF method are identified. A simplified two-state collisional radiative model is then used to establish scaling relations between the LCIF, electron density, and reduced electric fields (E/N). The procedure used to generate, detect and calibrate the LCIF in controlled plasma environments is discussed in detail. LCIF emanating from an argon discharge is then presented for electron densities spanning 109 e cm–3 to 1012 e cm–3 and reduced electric fields spanning 0.1 Tdmore » to 40 Td. Lastly, application of the LCIF technique for measuring the spatial distribution of both electron densities and reduced electric field is demonstrated.« less

  16. Dimeric fluorescent energy transfer dyes comprising asymmetric cyanine azole-indolenine chromophores

    DOE Patents [OSTI]

    Glazer, Alexander N.; Benson, Scott C.

    1998-01-01

    Novel fluorescent heterodimeric DNA-staining energy transfer dyes are provided combining asymmetric cyanine azole-indolenine dyes, which provide for strong DNA affinity, large Stokes shifts and emission in the red region of the spectrum. The dyes find particular application in gel electrophoresis and for labels which may be bound to a variety of compositions in a variety of contexts. Kits and individual compounds are provided, where the kits find use for simultaneous detection of a variety of moieties, particularly using a single narrow wavelength irradiation source. The individual compounds are characterized by high donor quenching and high affinity to dsDNA as a result of optimizing the length of the linking group separating the two chromophores.

  17. Functionalization of cubic boron nitride films with rhodamine B and their fluorescent properties

    SciTech Connect (OSTI)

    Liu, W. M.; Zhang, H. Y.; Wang, P. F.; Ye, Q.; Yang, Y.; He, B.; Bello, I.; Lee, S. T.; Zhang, W. J.

    2011-08-08

    Fluorophore-functionalized cubic boron nitride (cBN) films grown by chemical vapor deposition were achieved by immobilizing rhodamine B isothiocyanate onto their surfaces. To perform the immobilization, the cBN substrates were modified with amino groups by photochemical reaction between hydrogen-terminated cBN surfaces and allylamine. The surface analysis of hydrogen-terminated cBN films surfaces and after functionalization with x-ray photoelectron spectroscopy verified that rhodamine B was indeed attached to the cBN surfaces with covalent bonding. The rhodamine B-functionalized cBN surfaces showed significant variation in fluorescent spectra and confocal imaging upon the treatment in acidic or basic solutions.

  18. 100-OL-1 Operable Unit Field Portable X-Ray Fluorescence (XRF) Analyzer Pilot Study Plans

    SciTech Connect (OSTI)

    Bunn, Amoret L.; Fritz, Brad G.; Wellman, Dawn M.

    2014-07-15

    A pilot study is being conducted to support the approval of the Remedial Investigation/Feasibility Study (RI/FS) Work Plan to evaluate the 100-OL-1 Operable Unit (OU) pre-Hanford orchard lands. Based on comments received by the U.S. Environmental Protection Agency (EPA) and Washington State Department of Ecology, the pilot study will evaluate the use of field portable X-ray fluorescence (XRF) spectrometry measurements for evaluating lead and arsenic concentrations on the soil surface as an indicator of past use of lead arsenate pesticide residue in the OU. The work will be performed in the field during the summer of 2014, and assist in the planning for the characterization activities in the RI/FS.

  19. Integrated starting and running amalgam assembly for an electrodeless fluorescent lamp

    DOE Patents [OSTI]

    Borowiec, Joseph Christopher; Cocoma, John Paul; Roberts, Victor David

    1998-01-01

    An integrated starting and running amalgam assembly for an electrodeless SEF fluorescent lamp includes a wire mesh amalgam support constructed to jointly optimize positions of a starting amalgam and a running amalgam in the lamp, thereby optimizing mercury vapor pressure in the lamp during both starting and steady-state operation in order to rapidly achieve and maintain high light output. The wire mesh amalgam support is constructed to support the starting amalgam toward one end thereof and the running amalgam toward the other end thereof, and the wire mesh is rolled for friction-fitting within the exhaust tube of the lamp. The positions of the starting and running amalgams on the wire mesh are jointly optimized such that high light output is achieved quickly and maintained, while avoiding any significant reduction in light output between starting and running operation.

  20. Probing the photoluminescence properties of gold nanoclusters by fluorescence lifetime correlation spectroscopy

    SciTech Connect (OSTI)

    Yuan, C. T. Lin, T. N.; Shen, J. L.; Center for Biomedical Technology, Chung Yuan Christian University, Taiwan ; Lin, C. A.; Chang, W. H.; Department of Biomedical Engineering, Chung Yuan Christian University, Taiwan ; Cheng, H. W.; Tang, J.

    2013-12-21

    Gold nanoclusters (Au NCs) have attracted much attention for promising applications in biological imaging owing to their tiny sizes and biocompatibility. So far, most efforts have been focused on the strategies for fabricating high-quality Au NCs and then characterized by conventional ensemble measurement. Here, a fusion single-molecule technique combining fluorescence correlation spectroscopy and time-correlated single-photon counting can be successfully applied to probe the photoluminescence (PL) properties for sparse Au NCs. In this case, the triplet-state dynamics and diffusion process can be observed simultaneously and the relevant time constants can be derived. This work provides a complementary insight into the PL mechanism at the molecular levels for Au NCs in solution.

  1. Highly efficient electroluminescence from a solution-processable thermally activated delayed fluorescence emitter

    SciTech Connect (OSTI)

    Wada, Yoshimasa; Kubo, Shosei; Suzuki, Katsuaki; Kaji, Hironori; Shizu, Katsuyuki; Tanaka, Hiroyuki; Adachi, Chihaya

    2015-11-02

    We developed a thermally activated delayed fluorescence (TADF) emitter, 2,4,6-tris(4-(9,9-dimethylacridan-10-yl)phenyl)-1,3,5-triazine (3ACR-TRZ), suitable for use in solution-processed organic light-emitting diodes (OLEDs). When doped into 4,4′-bis(carbazol-9-yl)biphenyl (CBP) host at 16 wt. %, 3ACR-TRZ showed a high photoluminescence quantum yield of 98%. Transient photoluminescence decay measurements of the 16 wt. % 3ACR-TRZ:CBP film confirmed that 3ACR-TRZ exhibits efficient TADF with a triplet-to-light conversion efficiency of 96%. This high conversion efficiency makes 3ACR-TRZ attractive as an emitting dopant in OLEDs. Using 3ACR-TRZ as an emitter, we fabricated a solution-processed OLED exhibiting a maximum external quantum efficiency of 18.6%.

  2. X-Ray Fluorescence to Determine Zn in Bolivian Children using Hair Samples

    SciTech Connect (OSTI)

    Tellería Narvaez, C.A.; Fernández Alcázar, S.; Barrientos Zamora, F.G.; Chungara Castro, J.; Luna Lauracia, I.; Mamani Tola, H.; Mita Peralta, E.; Muñoz Gosálvez, A.O.; Romero Bolaños, L.E.; Ramírez Ávila, G.M.

    2014-06-15

    As a first step in the evaluation of nutritional levels in Bolivian children (8–13 years-old), we carried out X-Ray Fluorescence measurements in hair samples of children belonging to different social classes and living either in rural areas or in cities. The aim of this study is to contribute to health policies tending to improve the global health of children and consequently avoid malnutrition. Our method intends to have maximum reliability and at the same time be as simple as possible from an experimental point of view. Additionally, we use this method to determine some other elements such as Fe, Cu, Pb, As and Hg, the latter three considered as contaminants that could be present in children living in areas which neighbor mines and industries. This work will be complemented by some biological and medical tests.

  3. 2D laser-collision induced fluorescence in low-pressure argon discharges

    SciTech Connect (OSTI)

    Barnat, E. V.; Weatherford, B. R.

    2015-09-25

    Development and application of laser-collision induced fluorescence (LCIF) diagnostic technique is presented for the use of interrogating argon plasma discharges. Key atomic states of argon utilized for the LCIF method are identified. A simplified two-state collisional radiative model is then used to establish scaling relations between the LCIF, electron density, and reduced electric fields (E/N). The procedure used to generate, detect and calibrate the LCIF in controlled plasma environments is discussed in detail. LCIF emanating from an argon discharge is then presented for electron densities spanning 109 e cm–3 to 1012 e cm–3 and reduced electric fields spanning 0.1 Td to 40 Td. Lastly, application of the LCIF technique for measuring the spatial distribution of both electron densities and reduced electric field is demonstrated.

  4. Mercury reduction studies to facilitate the thermal decontamination of phosphor powder residues from spent fluorescent lamps

    SciTech Connect (OSTI)

    Alves Durao, Walter; Andreva de Castro, Camila; Carvalhinho Windmoeller, Claudia

    2008-11-15

    This work investigates the thermal release of mercury from phosphor powder of spent fluorescent lamps. The treatment conditions and the ability of various reducing agents (primarily sodium borohydride) to lower the overall heating temperature required to improve the release of Hg have been evaluated. Hg species in samples were monitored in a thermal desorption atomic absorption spectrometer system, and total mercury was analyzed in a cold vapor atomic absorption spectrometer. Sodium borohydride was the best reducing agent among the ones studied. However, citric acid presented a high capacity to weaken mercury bonds with the matrix. When the sample was crushed with sodium borohydride for 40 min in a mass ratio of 10:1 (sample:reducing agent) and submitted to thermal treatment at 300 deg. C for 2 h, the concentration of mercury in a phosphor powder sample with 103 mg kg{sup -1} of mercury reached 6.6 mg kg{sup -1}.

  5. Full-direct method for imaging pharmacokinetic parameters in dynamic fluorescence molecular tomography

    SciTech Connect (OSTI)

    Zhang, Guanglei; Pu, Huangsheng; Liu, Fei; Bai, Jing; He, Wei; Luo, Jianwen

    2015-02-23

    Images of pharmacokinetic parameters (also known as parametric images) in dynamic fluorescence molecular tomography (FMT) can provide three-dimensional metabolic information for biological studies and drug development. However, the ill-posed nature of FMT and the high temporal variation of fluorophore concentration together make it difficult to obtain accurate parametric images in small animals in vivo. In this letter, we present a method to directly reconstruct the parametric images from the boundary measurements based on hybrid FMT/X-ray computed tomography (XCT) system. This method can not only utilize structural priors obtained from the XCT system to mitigate the ill-posedness of FMT but also make full use of the temporal correlations of boundary measurements to model the high temporal variation of fluorophore concentration. The results of numerical simulation and mouse experiment demonstrate that the proposed method leads to significant improvements in the reconstruction quality of parametric images.

  6. Identification Of Natural Dyes On Archaeological Textile Objects Using Laser Induced Fluorescent Technique

    SciTech Connect (OSTI)

    Abdel-Kareem, O.; Eltokhy, A.; Harith, M. A.

    2011-09-22

    This study aims to evaluate the use of Laser Fluorescent as a non-destructive technique for identification of natural dyes on archaeological textile objects. In this study wool textile samples were dyed with 10 natural dyes such as cochineal, cutch, henna, indigo, Lac, madder, safflower, saffron, sumac and turmeric. These dyes common present on archaeological textile objects to be used as standard dyed textile samples. These selected natural dyes will be used as known references that can be used a guide to identify unknown archaeological dyes. The dyed textile samples were investigated with laser radiation in different wavelengths to detect the best wavelengths for identification each dye. This study confirms that Laser Florescent is very useful and a rapid technique can be used as a non-destructive technique for identification of natural dyes on archaeological textile objects. The results obtained with this study can be a guide for all conservators in identification of natural organic dyes on archaeological textile objects.

  7. BIOENERGIZEME INFOGRAPHIC CHALLENGE: Biomass: Types/Characteristics |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Biomass: Types/Characteristics BIOENERGIZEME INFOGRAPHIC CHALLENGE: Biomass: Types/Characteristics BIOENERGIZEME INFOGRAPHIC CHALLENGE: Biomass: Types/Characteristics This infographic was created by students from Albany Academies and Academy of the Holy Names in Albany, NY, as part of the U.S. Department of Energy-BioenergizeME Infographic Challenge. The BioenergizeME Infographic Challenge encourages young people to improve their foundational understanding of bioenergy,

  8. Role of amyloids in type II diabetes

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    July » Role of amyloids in type II diabetes Role of amyloids in type II diabetes A collaboration between Los Alamos, Yale University, and Worcester Polytechnic Institute published research that sheds light on pathological properties of amyloids identified in type II diabetes. July 6, 2016 Schematic of human amyloid (blue) partially removing a lipid bilayer (model membrane) on a solid support. Schematic of human amyloid (blue) partially removing a lipid bilayer (model membrane) on a solid

  9. Types of Fuel Cells | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fuel Cells » Types of Fuel Cells Types of Fuel Cells Fuel cells are classified primarily by the kind of electrolyte they employ. This classification determines the kind of electro-chemical reactions that take place in the cell, the kind of catalysts required, the temperature range in which the cell operates, the fuel required, and other factors. These characteristics, in turn, affect the applications for which these cells are most suitable. There are several types of fuel cells currently under

  10. Types of Hydropower Plants | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Plants Types of Hydropower Plants There are three types of hydropower facilities: impoundment, diversion, and pumped storage. Some hydropower plants use dams and some do not. The images below show both types of hydropower plants. Many dams were built for other purposes and hydropower was added later. In the United States, there are about 80,000 dams of which only 2,400 produce power. The other dams are for recreation, stock/farm ponds, flood control, water supply, and irrigation. Hydropower

  11. Rapid method for measuring clastogenic fingerprints using fluorescence in situ hybridization

    DOE Patents [OSTI]

    Lucas, Joe N.

    2000-01-01

    A method is provided for determining a clastogenic signature of a sample of chromosomes by quantifying a frequency of a first type of chromosome aberration present in the sample; quantifying a frequency of a second, different type of chromosome aberration present in the sample; and comparing the frequency of the first type of chromosome aberration to the frequency of the second type of chromosome aberration. A method is also provided for using that clastogenic signature to identify a clastogenic agent or dosage to which the cells were exposed.

  12. Development of a Cell-Based Fluorescence Resonance Energy Transfer Reporter for Bacillus anthracis Lethal Factor Protease

    SciTech Connect (OSTI)

    Kimura, R H; Steenblock, E R; Camarero, J A

    2007-03-22

    We report the construction of a cell-based fluorescent reporter for anthrax lethal factor (LF) protease activity using the principle of fluorescence resonance energy transfer (FRET). This was accomplished by engineering an Escherichia coli cell line to express a genetically encoded FRET reporter and LF protease. Both proteins were encoded in two different expression plasmids under the control of different tightly controlled inducible promoters. The FRET-based reporter was designed to contain a LF recognition sequence flanked by the FRET pair formed by CyPet and YPet fluorescent proteins. The length of the linker between both fluorescent proteins was optimized using a flexible peptide linker containing several Gly-Gly-Ser repeats. Our results indicate that this FRET-based LF reporter was readily expressed in E. coli cells showing high levels of FRET in vivo in the absence of LF. The FRET signal, however, decreased 5 times after inducing LF expression in the same cell. These results suggest that this cell-based LF FRET reporter may be used to screen genetically encoded libraries in vivo against LF.

  13. Red-shifted fluorescent proteins mPlum and mRaspberry and polynucleotides encoding the same

    DOE Patents [OSTI]

    Tsien, Roger Y.; Wang, Lei

    2008-07-01

    Methods using somatic hypermutation (SHM) for producing polypeptide and nucleic acid variants, and nucleic acids encoding such polypeptide variants are disclosed. Such variants may have desired properties. Also disclosed are novel polypeptides, such as improved fluorescent proteins, produced by the novel methods, and nucleic acids, vectors, and host cells comprising such vectors.

  14. Fluorescence energy transfer efficiency in labeled yeast cytochrome c: a rapid screen for ion biocompatibility in aqueous ionic liquids

    SciTech Connect (OSTI)

    Baker, Sheila N; Zhao, Hua; Pandey, Siddharth; Heller, William T; Bright, Frank; Baker, Gary A

    2011-01-01

    A fluorescence energy transfer de-quenching assay was implemented to follow the equilibrium unfolding behaviour of site-specific tetramethylrhodamine-labelled yeast cytochrome c in aqueous ionic liquid solutions; additionally, this approach offers the prospect of naked eye screening for biocompatible ion combinations in hydrated ionic liquids.

  15. Synthesis and preliminary biological evaluations of fluorescent or 149Promethium labeled Trastuzumab-polyethylenimine

    SciTech Connect (OSTI)

    Fitzsimmons, Jonathan; Nayak, Tapan; Cutler, Cathy; Atcher, Robert

    2015-12-30

    Radioimmunotherapy utilize a targeting antibody coupled to a therapeutic isotope to target and treat a tumor or disease. In this study we examine the synthesis and cell binding of a polymer scaffold containing a radiotherapeutic isotope and a targeting antibody. Methods: The multistep synthesis of a fluorescent or 149Promethium-labeled Trastuzumab-polyethyleneimine (PEI), Trastuzumab, or PEI is described. In vitro uptake, internalization and/or the binding affinity to the Her2/neu expressing human breast adenocarcinoma SKBr3 cells was investigated with the labeled compounds. Fluorescent-labeled Trastuzumab-PEI was internalized more into cells at 2 and 18 h than fluorescent-labeled Trastuzumab or PEI. The fluorescent-labeled Trastuzumab was concentrated on the cell surface at 2 and 18 h and the labeled PEI had minimal uptake. DOTA-PEI was prepared and contained an average of 16 chelates per PEI; the compound was radio-labeled with 149Promethium and conjugated to Trastuzumab. The purified 149Pm-DOTA-PEI-Trastuzumab had a radiochemical purity of 96.7% and a specific activity of 0.118 TBq/g. The compound demonstrated a dissociation constant for the Her2/neu receptor of 20.30 ± 6.91 nM. In conclusion, the results indicate the DOTA-PEI-Trastuzumab compound has potential as a targeted therapeutic carrier, and future in vivo studies should be performed.

  16. Dose Response and Post-irradiation Characteristics of the Sunna 535-nm Photo-Fluorescent Film Dosimeter

    SciTech Connect (OSTI)

    Murphy, Mark K.; Kovacs, Andras; Miller, Steven D.; Mclaughlin, William L.

    2003-06-09

    Results of characterization studies on one of the first versions of the Sunna photo-fluorescent dosimeter ? have previously been reported, and describe the performance of the red fluorescence component. This present paper describes dose response and post-irradiation characteristics of the green fluorescence component from the same dosimeter film (Sunna Model ?), which is manufactured using the injection molding technique. This production method may supply batch sizes on the order of 1 million dosimeter film elements while maintaining a signal precision (1?) on the order of ?1% without the need to correct for variability of film thickness. The dosimeter is a 1-cm by 3-cm polymeric film of 0.5-mm thickness that emits green fluorescence at intensities increasing almost linearly with dose. The data presented include dose response, post-irradiation growth, heat treatment, dosimeter aging, dose rate dependence, energy dependence, dose fractionation, variation of response within a batch, and the stability of the fluorimeter response. The results indicate that, as a routine dosimeter, the green signal provides a broad range of response at food irradiation (0.3 to 5 kGy), medical sterilization (5 to 40 kGy), and polymer cross-linking (40 to 250 kGy) dose levels.

  17. Coligand-regulated assembly, fluorescence, and magnetic properties of Co(II) and Cd(II) complexes with a non-coplanar dicarboxylate

    SciTech Connect (OSTI)

    Xin, Ling-Yun; Liu, Guang-Zhen; Ma, Lu-Fang; Wang, Li-Ya

    2013-10-15

    A non-coplanar dicarboxylate ndca (H{sub 2}ndca=5-norbornene-2,3-dicarboxylic acid), combining with various dipyridyl-typed tectons, constructs six Cd(II)/Co(II) coordination polymers under hydrothermal conditions, namely [Co(ndca)(H{sub 2}O)]{sub n} (1), ([Co(ndca)(bpe)(H{sub 2}O)]·H{sub 2}O){sub n} (2), [Co(ndca)(bpa){sub 0.5}(H{sub 2}O)]{sub n} (3), [Cd(ndca)(bpe)(H{sub 2}O)]{sub n} (4), ([Cd(ndca)(bpa)(H{sub 2}O)]·0.5H{sub 2}O){sub n} (5), and ([Cd(ndca)(bpp) (H{sub 2}O)]·H{sub 2}O){sub n} (6) (bpe=1,2-di(4-pyridyl)ethylene, bpa=1,2-bi(4-pyridyl)ethane, and bpp=1,3-bis(4-pyridyl)propane). All these compounds contain various metal(II)–carboxylate motifs, including carboxylate binuclear (2, 4, 5), carboxylate chain (1, 6) and carboxylate layer (3), which are further extended by dipyridyl-typed coligands to afford a vast diversity of the structures with 2D pyknotic layers (1, 6), 2D open layer (5), 2D→3D interpenetrated networks (2,4), and 3D pillared-layer framework (3), respectively. In addition, fluorescent spectra of Cd(II) complexes and magnetic properties of Co(II) complexes are also given. - Graphical abstract: Six various cadmium(II)/cobalt(II)–organic frameworks were constructed by 5-norbornene-2,3-dicarboxylic acid and different bis(pyridine) rod-like tectons, and Cd (II) complexes exhibit blue–violet emissions, whereas Co (II) complexes show antiferromagnetic behaviours. Display Omitted.

  18. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  19. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  20. Serum markers for type II diabetes mellitus

    DOE Patents [OSTI]

    Metz, Thomas O; Qian, Wei-Jun; Jacobs, Jon M; Polpitiya, Ashoka D; Camp, II, David G; Smith, Richard D

    2014-03-18

    A method for identifying persons with increased risk of developing type 2 diabetes mellitus utilizing selected biomarkers described hereafter either alone or in combination. The present invention allows for broad based, reliable, screening of large population bases and provides other advantages, including the formulation of effective strategies for characterizing, archiving, and contrasting data from multiple sample types under varying conditions.

  1. Archived Reference Building Type: Small Hotel

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  2. Archived Reference Building Type: Large Hotel

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  3. Archived Reference Building Type: Small Hotel

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  4. Archived Reference Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  5. Archived Reference Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  6. Archived Reference Building Type: Outpatient health care

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  7. Archived Reference Building Type: Outpatient health care

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  8. Archived Reference Building Type: Strip mall

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zonesis available for reference.Current versionsare also available.

  9. Archived Reference Building Type: Strip mall

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  10. Archived Reference Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  11. Archived Reference Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  12. Archived Reference Building Type: Large Hotel

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  13. Archived Reference Building Type: Quick service restaurant

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  14. Archived Reference Building Type: Quick service restaurant

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  15. Archived Reference Building Type: Full service restaurant

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  16. Archived Reference Building Type: Full service restaurant

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  17. Archived Reference Building Type: Midrise Apartment

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zonesis available for reference.Current versionsare also available.

  18. Archived Reference Building Type: Midrise Apartment

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  19. Optical and electronic properties of delafossite CuBO{sub 2}p-type transparent conducting oxide

    SciTech Connect (OSTI)

    Ruttanapun, Chesta E-mail: krchesta@kmitl.ac.th

    2013-09-21

    CuBO{sub 2} delafossite was prepared by solid state reaction and calcined/sintered at 1005?C. The optical properties of this p-type transparent conducting oxide were investigated. Its crystal structure, morphology, composition, oxygen decomposition, and optical and electronic properties were characterized by X-ray diffraction, scanning electron microscopy, X-ray photoelectron spectroscopy, thermal gravimetric analysis (TGA), ultraviolet-visible-near-infrared (UV-VIS-NIR) and fluorescence spectroscopies, Seebeck coefficient, and electrical conductivity measurements. CuBO{sub 2} delafossite possesses a hexagonal space group R3{sup }m. TGA indicated a weight loss of 10%, which was attributed to excess oxygen. The positive Seebeck coefficient confirmed p-type behavior. Emission at 355?nm indicated a direct band type transition, and the UV-VIS-NIR spectrum indicated an optical direct gap of 3.6?eV. Activation energies for carrier production and electrical conduction were 0.147 and 0.58?eV, respectively, indicating the thermal activation of carriers. CuBO{sub 2} delafossite is a p-type transparent conducting oxide with a wide band gap and may have potential in industrial p-type electrodes.

  20. Table lamp with dynamically controlled lighting distribution and uniformly illuminated luminous shade

    DOE Patents [OSTI]

    Siminovitch, Michael J.; Page, Erik R.

    2002-01-01

    A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) or other lamps arranged vertically, i.e. one lamp above the other, with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum ensures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. In a particular configuration, the reflective septum is bowl shaped, with the upper CFL sitting in the bowl, and a luminous shade hanging down from the bowl. The lower CFL provides both task lighting and uniform shade luminance. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. However, other types of lamps, including incandescent, halogen, and LEDs can also be used in the fixture. The lighting system may be designed for the home, hospitality, office or other environments.

  1. Nuclear Resonance Fluorescence to Measure Plutonium Mass in Spent Nuclear Fuel

    SciTech Connect (OSTI)

    Ludewigt, Bernhard A; Quiter, Brian J.; Ambers, Scott D.

    2011-01-14

    The Next Generation Safeguard Initiative (NGSI) of the U.S Department of Energy is supporting a multi-lab/university collaboration to quantify the plutonium (Pu) mass in spent nuclear fuel (SNF) assemblies and to detect the diversion of pins with non-destructive assay (NDA) methods. The following 14 NDA techniques are being studied: Delayed Neutrons, Differential Die-Away, Differential Die-Away Self-Interrogation, Lead Slowing Down Spectrometer, Neutron Multiplicity, Passive Neutron Albedo Reactivity, Total Neutron (Gross Neutron), X-Ray Fluorescence, {sup 252}Cf Interrogation with Prompt Neutron Detection, Delayed Gamma, Nuclear Resonance Fluorescence, Passive Prompt Gamma, Self-integration Neutron Resonance Densitometry, and Neutron Resonance Transmission Analysis. Understanding and maturity of the techniques vary greatly, ranging from decades old, well-understood methods to new approaches. Nuclear Resonance Fluorescence (NRF) is a technique that had not previously been studied for SNF assay or similar applications. Since NRF generates isotope-specific signals, the promise and appeal of the technique lies in its potential to directly measure the amount of a specific isotope in an SNF assay target. The objectives of this study were to design and model suitable NRF measurement methods, to quantify capabilities and corresponding instrumentation requirements, and to evaluate prospects and the potential of NRF for SNF assay. The main challenge of the technique is to achieve the sensitivity and precision, i.e., to accumulate sufficient counting statistics, required for quantifying the mass of Pu isotopes in SNF assemblies. Systematic errors, considered a lesser problem for a direct measurement and only briefly discussed in this report, need to be evaluated for specific instrument designs in the future. Also, since the technical capability of using NRF to measure Pu in SNF has not been established, this report does not directly address issues such as cost, size

  2. Membrane-Associated Methane Monooygenase from Type X and Type I Methanotrophs

    SciTech Connect (OSTI)

    Antholine, William E.; DiSpirito, Alan A.

    2009-11-30

    Membrane-Associated Methane Monooxygenases from Type X and Type I Methanotrophs A.A. DiSirito and W.E. Antholine Project Number: DE-FG02-00ER15446 Final project report.

  3. Types of Hydropower Turbines | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Turbines Types of Hydropower Turbines There are two main types of hydro turbines: impulse and reaction. The type of hydropower turbine selected for a project is based on the height of standing water-referred to as "head"-and the flow, or volume of water, at the site. Other deciding factors include how deep the turbine must be set, efficiency, and cost. Terms used on this page are defined in the glossary. Impulse Turbine The impulse turbine generally uses the velocity of the water to

  4. Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps CALiPER Benchmark Report

    SciTech Connect (OSTI)

    Myer, Michael; Paget, Maria L.; Lingard, Robert D.

    2009-01-16

    The Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) Program was established in 2006 to investigate the performance of light-emitting diode (LED) based luminaires and replacement lamps. To help users better compare LED products with conventional lighting technologies, CALiPER has also performed benchmark research and testing of traditional (i.e., non-LED) lamps and fixtures. This benchmark report addresses standard 4-foot fluorescent lamps (i.e., T12 and T8) and the 2-foot by 4-foot recessed troffers in which they are commonly used. This report also examines available LED replacements for T12 and T8 fluorescent lamps, and their application in fluorescent troffers. The construction and operation of linear fluorescent lamps and troffers are discussed, as well as fluorescent lamp and fixture performance, based on manufacturer data and CALiPER benchmark testing. In addition, the report describes LED replacements for linear fluorescent lamps, and compares their bare lamp and in situ performance with fluorescent benchmarks on a range of standard lighting measures, including power usage, light output and distribution, efficacy, correlated color temperature, and the color rendering index. Potential performance and application issues indicated by CALiPER testing results are also examined.

  5. Ultrasound guided fluorescence molecular tomography with improved quantification by an attenuation compensated born-normalization and in vivo preclinical study of cancer

    SciTech Connect (OSTI)

    Li, Baoqiang; Berti, Romain; Abran, Maxime; Lesage, Frédéric; Montreal Heart Institute, Montreal, Quebec H1T 1C8

    2014-05-15

    Ultrasound imaging, having the advantages of low-cost and non-invasiveness over MRI and X-ray CT, was reported by several studies as an adequate complement to fluorescence molecular tomography with the perspective of improving localization and quantification of fluorescent molecular targets in vivo. Based on the previous work, an improved dual-modality Fluorescence-Ultrasound imaging system was developed and then validated in imaging study with preclinical tumor model. Ultrasound imaging and a profilometer were used to obtain the anatomical prior information and 3D surface, separately, to precisely extract the tissue boundary on both sides of sample in order to achieve improved fluorescence reconstruction. Furthermore, a pattern-based fluorescence reconstruction on the detection side was incorporated to enable dimensional reduction of the dataset while keeping the useful information for reconstruction. Due to its putative role in the current imaging geometry and the chosen reconstruction technique, we developed an attenuation compensated Born-normalization method to reduce the attenuation effects and cancel off experimental factors when collecting quantitative fluorescence datasets over large area. Results of both simulation and phantom study demonstrated that fluorescent targets could be recovered accurately and quantitatively using this reconstruction mechanism. Finally, in vivo experiment confirms that the imaging system associated with the proposed image reconstruction approach was able to extract both functional and anatomical information, thereby improving quantification and localization of molecular targets.

  6. DOE CALiPER Program, Report 21.2: Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers

    SciTech Connect (OSTI)

    Miller, Naomi J.; Perrin, Tess E.; Royer, Michael P.; Wilkerson, Andrea M.; Beeson, Tracy A.

    2014-05-20

    Although lensed troffers are numerous, there are many other types of optical systems as well. This report looked at the performance of three linear (T8) LED lamps chosen primarily based on their luminous intensity distributions (narrow, medium, and wide beam angles) as well as a benchmark fluorescent lamp in five different troffer types. Also included are the results of a subjective evaluation. Results show that linear (T8) LED lamps can improve luminaire efficiency in K12-lensed and parabolic-louvered troffers, effect little change in volumetric and high-performance diffuse-lensed type luminaires, but reduce efficiency in recessed indirect troffers. These changes can be accompanied by visual appearance and visual comfort consequences, especially when LED lamps with clear lenses and narrow distributions are installed. Linear (T8) LED lamps with diffuse apertures exhibited wider beam angles, performed more similarly to fluorescent lamps, and received better ratings from observers. Guidance is provided on which luminaires are the best candidates for retrofitting with linear (T8) LED lamps.

  7. Property:CompanyType | Open Energy Information

    Open Energy Info (EERE)

    profit Pages using the property "CompanyType" Showing 4 pages using this property. E Eco Wave Power Ltd. + For Profit + N Nvision.Energy + For Profit + R Rentechno + For Profit...

  8. Renewable Energy Opportunities by Renovation Type

    Broader source: Energy.gov [DOE]

    Renewable energy opportunities should be considered and identified in the earliest stages of Federal project planning and the team should assess the renewable energy options based on the type of...

  9. Development of Osaka gas type planar SOFC

    SciTech Connect (OSTI)

    Iha, M.; Shiratori, A.; Chikagawa, O.

    1996-12-31

    Osaka Gas Co. has been developing a planar type SOFC (OG type SOFC) which has a suitable structure for stacking. Murata Mfg. Co. has begun to develop the OG type SOFC stack through joint program since 1993. Figure 1 shows OG type cell structure. Because each cell is sustained by cell holders acting air manifold, the load of upper cell is not put on the lower cells. Single cell is composed of 3-layered membrane and LaCrO{sub 3} separator. 5 single cells are mounted on the cell holder, connected with Ni felt electrically, and bonded by glassy material sealant. We call the 5-cell stack a unit. Stacking 13 units, we succeeded 870 W generation in 1993. But the power density was low, 0.11 Wcm{sup -2} because of crack in the electrolyte and gas leakage at some cells.

  10. Defining photometric peculiar type Ia supernovae

    SciTech Connect (OSTI)

    González-Gaitán, S.; Pignata, G.; Förster, F.; Gutiérrez, C. P.; Bufano, F.; Galbany, L.; Hamuy, M.; De Jaeger, T.; Hsiao, E. Y.; Phillips, M. M.; Folatelli, G.; Anderson, J. P.

    2014-11-10

    We present a new photometric identification technique for SN 1991bg-like type Ia supernovae (SNe Ia), i.e., objects with light curve characteristics such as later primary maxima and the absence of a secondary peak in redder filters. This method is capable of selecting this sub-group from the normal type Ia population. Furthermore, we find that recently identified peculiar sub-types such as SNe Iax and super-Chandrasekhar SNe Ia have photometric characteristics similar to 91bg-like SNe Ia, namely, the absence of secondary maxima and shoulders at longer wavelengths, and can also be classified with our technique. The similarity of these different SN Ia sub-groups perhaps suggests common physical conditions. This typing methodology permits the photometric identification of peculiar SNe Ia in large upcoming wide-field surveys either to study them further or to obtain a pure sample of normal SNe Ia for cosmological studies.

  11. Types of Insulation | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Weatherize » Insulation » Types of Insulation Types of Insulation In existing homes, cellulose (here) or other loose-fill materials can be installed in building cavities through holes drilled (usually) on the exterior of the house. After the installation, the holes are plugged and finish materials replaced. | Photo courtesy of Cellulose Insulation Manufacturers Association. In existing homes, cellulose (here) or other loose-fill materials can be installed in building cavities through holes

  12. Development of Ta-based Superconducting Tunnel Junction X-ray Detectors for Fluorescence XAS

    SciTech Connect (OSTI)

    Friedrich, S; Drury, O; Hall, J; Cantor, R

    2009-09-23

    We are developing superconducting tunnel junction (STJ) soft X-ray detectors for chemical analysis of dilute samples by fluorescence-detected X-ray absorption spectroscopy (XAS). Our 36-pixel Nb-based STJ spectrometer covers a solid angle {Omega}/4{pi} {approx} 10{sup -3}, offers an energy resolution of {approx}10-20 eV FWHM for energies up to {approx}1 keV, and can be operated at total count rates of {approx}10{sup 6} counts/s. For increased quantum efficiency and cleaner response function, we have now started the development of Ta-based STJ detector arrays. Initial devices modeled after our Nb-based STJs have an energy resolution below 10 eV FWHM for X-ray energies below 1 keV, and pulse rise time discrimination can be used to improve their response function for energies up to several keV. We discuss the performance of the Ta-STJs and outline steps towards the next-generation of large STJ detector arrays with higher sensitivity.

  13. A multi-channel monolithic Ge detector system for fluorescence x-ray absorption spectroscopy

    SciTech Connect (OSTI)

    Bucher, J.J.; Allen, P.G.; Edelstein, N.M.; Shuh, D.K.; Madden, N.W.; Cork, C.; Luke, P.; Pehl, D.; Malone, D.

    1995-03-01

    Construction and performance of a monolithic quad-pixel Ge detector for fluorescence x-ray absorption spectroscopy (XAS) at synchrotron radiation sources are described. The detector semiconductor element has an active surface area of 4.0 cm{sup 2} which is electrically separated into four 1.0 cm{sup 2} pixels, with little interfacial dead volume. Spatial response of the array shows that cross-talk between adjacent pixels is < 10% for 5.9 keV photons that fall within 0.5 mm of the pixel boundaries. The detector electronics system uses pre-amplifiers built at LBNL with commercial Tennelec Model TC 244 amplifiers. Using an {sup 55}Fe test source (MnK{sub {alpha}}, 5.9 keV), energy resolution of better than 200 eV is achieved with a 4 {mu}sec peaking time. At 0.5 {mu}sec peaking time, pulse pileup results in a 75% throughput efficiency for an incoming count rate of 100 kHz. Initial XAS fluoresncece measurements at the beamline 4 wiggler end stations at SSRL show that the detector system has several advantages over commercial x-ray spectrometers for low-concentration counting.

  14. Fluorescence analysis can identify movable oil in self-sourcing reservoirs

    SciTech Connect (OSTI)

    Calhoun, G.G.

    1995-06-05

    The recent surge of activity involving self-sourcing reservoirs and horizontal drilling recognizes a little tapped niche in the domestic energy mix. Such prolific pays as the Cretaceous Bakken and Austin Chalk have drawn research interest and large amounts of investment capital. Fluorescence analysis can discern movable oil--as opposed to exhausted source rock--in such reservoirs with an inexpensive test. Other potential targets are the Cretaceous Mesaverde in the Piceance basin, Devonian New Albany shale in Kentucky, Devonian Antrim shale in the Michigan basin, and the Cretaceous Niobrara, Mancos, and Pierre formations in Colorado and New Mexico. To insure success in this niche this key question must be answered positively: Is movable oil present in the reservoir? Even if tectonic studies verify a system of open fractures, sonic logs confirm overpressuring in the zone, and resistivity logs document the maturity of the source, the ultimate question remains: Is movable oil in the fractures available to flow to the borehole? The paper explains a technique that will answer these questions.

  15. X chromosome aneuploidy in infertile women: Analysis by interphase fluorescent in situ hybridization

    SciTech Connect (OSTI)

    Morris, M.A.; Moix, I.; Mermillod, B.

    1994-09-01

    Up to 1 in 3 couples have a problem of infertility at some time in their lives. Sex chromosome anomalies are found in 5-10% of couples, with mosaic aneuploidy being a common finding in primary infertility. Recurrent spontaneous abortion (RSA), in contrast, is frequently associated with autosomal structural anomalies. We hypothesized that low-level mosaic X chromosome aneuploidy was associated with primary infertility but not with RSA. Three groups were studied: women from couples with primary infertillity (n=26); women with three or more spontaneous abortions (n=22); and age-matched normally fertile women (at least two pregnancies; n=28). Interphase fluorescent in situ hybridization (FISH) was used to determine X chromosome ploidy in 100 nuclei per patient, using a contig of three cosmids from MAO locus (kindly donated by W. Berger, Nijmegen). A control probe (chr. 15 centromere) was simultaneously hybridized, and only nuclei containing two control signals were scored for the X chromosome. The mean numbers of nuclei with two X chromosome signals were the same in all groups (Welch equality of means test: p>0.97). However, there is a significant difference between the variances of the primary infertile and RSA groups (Levene`s test: p=0.025 after Bonferrone correction for multiple testing). This provides preliminary support for the hypothesis of an association between primary infertility and low-level mosaic X chromosome aneuploidy.

  16. Algorithms for a hand-held miniature x-ray fluorescence analytical instrument

    SciTech Connect (OSTI)

    Elam, W.T.; Newman, D.; Ziemba, F.

    1998-12-31

    The purpose of this joint program was to provide technical assistance with the development of a Miniature X-ray Fluorescence (XRF) Analytical Instrument. This new XRF instrument is designed to overcome the weaknesses of spectrometers commercially available at the present time. Currently available XRF spectrometers (for a complete list see reference 1) convert spectral information to sample composition using the influence coefficients technique or the fundamental parameters method. They require either a standard sample with composition relatively close to the unknown or a detailed knowledge of the sample matrix. They also require a highly-trained operator and the results often depend on the capabilities of the operator. In addition, almost all existing field-portable, hand-held instruments use radioactive sources for excitation. Regulatory limits on such sources restrict them such that they can only provide relatively weak excitation. This limits all current hand-held XRF instruments to poor detection limits and/or long data collection times, in addition to the licensing requirements and disposal problems for radioactive sources. The new XRF instrument was developed jointly by Quantrad Sensor, Inc., the Naval Research Laboratory (NRL), and the Department of Energy (DOE). This report describes the analysis algorithms developed by NRL for the new instrument and the software which embodies them.

  17. Heat shock-induced interactions among nuclear HSFs detected by fluorescence cross-correlation spectroscopy

    SciTech Connect (OSTI)

    Pack, Chan-Gi; Ahn, Sang-Gun

    2015-07-31

    The cellular response to stress is primarily controlled in cells via transcriptional activation by heat shock factor 1 (HSF1). HSF1 is well-known to form homotrimers for activation upon heat shock and subsequently bind to target DNAs, such as heat-shock elements, by forming stress granules. A previous study demonstrated that nuclear HSF1 and HSF2 molecules in live cells interacted with target DNAs on the stress granules. However, the process underlying the binding interactions of HSF family in cells upon heat shock remains unclear. This study demonstrate for the first time that the interaction kinetics among nuclear HSF1, HSF2, and HSF4 upon heat shock can be detected directly in live cells using dual color fluorescence cross-correlation spectroscopy (FCCS). FCCS analyses indicated that the binding between HSFs was dramatically changed by heat shock. Interestingly, the recovery kinetics of interaction between HSF1 molecules after heat shock could be represented by changes in the relative interaction amplitude and mobility. - Highlights: • The binding interactions among nuclear HSFs were successfully detected. • The binding kinetics between HSF1s during recovery was quantified. • HSF2 and HSF4 strongly formed hetero-complex, even before heat shock. • Nuclear HSF2 and HSF4 bound to HSF1 only after heat shock.

  18. Highly Fluorescent Group 13 Metal Complexes with Cyclic, Aromatic Hydroxamic Acid Ligands

    SciTech Connect (OSTI)

    Seitz, Michael; Moore, Evan G.; Raymond, Kenneth N.

    2008-02-11

    The neutral complexes of two ligands based on the 1-oxo-2-hydroxy-isoquinoline (1,2-HOIQO) motif with group 13 metals (Al, Ga, In) show bright blue-violet luminescence in organic solvents. The corresponding transition can be attributed to ligand-centered singlet emission, characterized by a small Stokes shifts of only a few nm combined with lifetimes in the range between 1-3 ns. The fluorescence efficiency is high, with quantum yields of up to 37% in benzene solution. The crystal structure of one of the indium(III) complexes (trigonal space group R-3, a = b = 13.0384(15) {angstrom}, c = 32.870(8) {angstrom}, ? = {beta} = 90{sup o}, {gamma} = 120{sup o}, V = 4839.3(14) {angstrom}{sup 3}, Z = 6) shows a six-coordinate geometry around the indium center which is close to trigonal-prismatic, with a twist angle between the two trigonal faces of 20.7{sup o}. Time-dependent density functional theory (TD-DFT) calculations (Al and Ga: B3LYP/6-31G(d)); In: B3LYP/LANL2DZ of the fac and mer isomers with one of the two ligands indicate that there is no clear preference for either one of the isomeric forms of the metal complexes. In addition, the metal centers do not have a significant influence on the electronic structure, and as a consequence, on the predominant intraligand optical transitions.

  19. Note: Design of a full photon-timing recorder down to 1-ns resolution for fluorescence fluctuation measurements

    SciTech Connect (OSTI)

    Nishimura, Goro

    2015-10-15

    A photon timing recorder was realized in a field programmable gate array to capture all timing data of photons on multiple channels with down to a 1-ns resolution and to transfer all data to a host computer in real-time through universal serial bus with more than 10 M events/s transfer rate. The main concept is that photon time series can be regarded as a serial communication data stream. This recorder was successfully applied for simultaneous measurements of fluorescence fluctuation and lifetime of near-infrared dyes in solution. This design is not only limited to the fluorescence fluctuation measurement but also applicable to any kind of photon counting experiments in a nanosecond time range because of the simple and easily modifiable design.

  20. Single and two-photon fluorescence control of Er{sup 3+} ions by phase-shaped femtosecond laser pulse

    SciTech Connect (OSTI)

    Zhang, Shian Ding, Jingxin; Lu, Chenhui; Jia, Tianqing; Sun, Zhenrong; Xu, Shuwu; Qiu, Jianrong

    2014-01-06

    We experimentally demonstrate the control of the single and two-photon fluorescence (SPF and TPF) in Er{sup 3+} ions by shaping the femtosecond laser pulse with a π or square phase modulation. With the low laser intensity (8.4 × 10{sup 10} W/cm{sup 2}), SPF keeps a constant while TPF is effectively suppressed by the two control schemes. With the high laser intensity (1.2 × 10{sup 13} W/cm{sup 2}), both SPF and TPF are simultaneously enhanced or suppressed by the π phase modulation, and SPF is enhanced while TPF is effectively suppressed by the square phase modulation. The up/down-conversion fluorescence enhancement, suppression, or tuning by the optical control method can greatly expand its applications in various related fields.