Powered by Deep Web Technologies
Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

A Bright Idea: New Efficiency Standards for Incandescent and...  

Broader source: Energy.gov (indexed) [DOE]

A Bright Idea: New Efficiency Standards for Incandescent and Fluorescent Lights A Bright Idea: New Efficiency Standards for Incandescent and Fluorescent Lights July 21, 2009 -...

2

2014-04-11 Issuance: Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps; Notice of Proposed Rulemaking  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of proposed rulemaking regarding energy conservation standards for general service fluorescent lamps and incandescent reflectors lamps, as issued by the Assistant Secretary for Energy Efficiency and Renewable Energy on April 11, 2014.

3

Potential Environmental Impacts from the Metals in Incandescent, Compact Fluorescent Lamp (CFL), and Light-Emitting Diode (LED)  

E-Print Network [OSTI]

the lighting products are to be categorized as hazardous waste under existing U.S. federal and California state in lighting products without compromising their performance and useful lifespan. INTRODUCTION The U.S. Energy to increase energy efficiency for general lighting. Therefore, consumers are replacing incandescent light

Short, Daniel

4

Max Tech and Beyond: Fluorescent Lamps  

E-Print Network [OSTI]

Fluorescent Lamps and Incandescent Reflector Lamps; Finalmany end- use applications. Incandescent Outdoor Stationaryof color compared with the incandescent reference source is

Scholand, Michael

2012-01-01T23:59:59.000Z

5

Photonically Engineered Incandescent Emitter  

DOE Patents [OSTI]

A photonically engineered incandescence is disclosed. The emitter materials and photonic crystal structure can be chosen to modify or suppress thermal radiation above a cutoff wavelength, causing the emitter to selectively emit in the visible and near-infrared portions of the spectrum. An efficient incandescent lamp is enabled thereby. A method for fabricating a three-dimensional photonic crystal of a structural material, suitable for the incandescent emitter, is also disclosed.

Gee, James M. (Albuquerque, NM); Lin, Shawn-Yu (Albuquerque, NM); Fleming, James G. (Albuquerque, NM); Moreno, James B. (Albuquerque, NM)

2005-03-22T23:59:59.000Z

6

High efficiency incandescent lighting  

DOE Patents [OSTI]

Incandescent lighting structure. The structure includes a thermal emitter that can, but does not have to, include a first photonic crystal on its surface to tailor thermal emission coupled to, in a high-view-factor geometry, a second photonic filter selected to reflect infrared radiation back to the emitter while passing visible light. This structure is highly efficient as compared to standard incandescent light bulbs.

Bermel, Peter; Ilic, Ognjen; Chan, Walker R.; Musabeyoglu, Ahmet; Cukierman, Aviv Ruben; Harradon, Michael Robert; Celanovic, Ivan; Soljacic, Marin

2014-09-02T23:59:59.000Z

7

Energy-efficient incandescent lamp: Final report  

E-Print Network [OSTI]

of Energy Conserving Incandescent Lamps", J . Brett, R.July 1981. "Filaments for Incandescent Lamps with Radiation20-22 "Energy Saving Incandescent Lamps with Infrared

Verderber, R.

2010-01-01T23:59:59.000Z

8

The incandescent disposal system  

SciTech Connect (OSTI)

The electrotechnology device being introduced to the low-level waste market is an Incandescent Disposal System (IDS) for volume reduction and vitrification. The process changes the composition of the waste material, usually long molecular chains, into simple molecules and elements. It renders the volume of low-level wastes to a manageable solid vitrified residue, carbon black, and a water discharge. The solid material, which has been vitrified if silica is introduced into the waste stream, is an ideal inert filler. The carbon black is non-leaching and is readily available for vitrification as it comes out of the IDS.

Smith, R.G.

1996-03-01T23:59:59.000Z

9

Cost effectiveness of long life incandescent lamps and energy buttons  

SciTech Connect (OSTI)

Long-life replacement lamps for the incandescent lamp have been evaluated with regard to their cost effectiveness. The replacements include the use of energy buttons that extend lamp life as well as an adaptive fluorescent circline lamp that will fit into existing incandescent lamp sockets. The initial, operating, and replacement costs for one million lumen hours are determined for each lamp system. It is found that the most important component lighting cost is the operating cost. Using lamps that are less efficient or devices that cause lamps to operate less efficiently are not cost-effective. The adaptive fluorescent circline lamp, even at an initial unit cost of $20.00, is the most cost-effective source of illumination compared to the incandescent lamp and lamp systems examined.

Verderber, R.; Morse, O.

1980-04-07T23:59:59.000Z

10

Underwater Lighting by Submerged Lasers and Incandescent Sources  

E-Print Network [OSTI]

and collimated underwater incandescent projector. The laser-collimated underwater incandescent projector used for beamBY SUBMERGED LASERS and Incandescent Sources DESCRIPTIVE

Duntley, Seibert Q

1971-01-01T23:59:59.000Z

11

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network [OSTI]

as any 1ong-li incandescent lamp or system evaluated in thisEFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGYEFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY

Verderber, Rudy

2013-01-01T23:59:59.000Z

12

General service incandescent lamp with improved efficiency  

SciTech Connect (OSTI)

A high efficiency general service incandescent lamp is disclosed. The disclosed improved general service incandescent lamp has an outer and an inner envelope. The inner envelope has a relatively small housing containing a halogen gas and a relatively high pressure efficient fill-gas and in which a low voltage filament is spatially disposed therein.

Berlec, I.

1985-06-18T23:59:59.000Z

13

Dual LED/incandescent security fixture  

DOE Patents [OSTI]

A dual LED and incandescent security lighting system uses a hybrid approach to LED illumination. It combines an ambient LED illuminator with a standard incandescent lamp on a motion control sensor. The LED illuminator will activate with the onset of darkness (daylight control) and typically remain on during the course of the night ("always on"). The LED illumination, typically amber, is sufficient to provide low to moderate level lighting coverage to the wall and ground area adjacent to and under the fixture. The incandescent lamp is integrated with a motion control circuit and sensor. When movement in the field of view is detected (after darkness), the incandescent lamp is switched on, providing an increased level of illumination to the area. Instead of an "always on" LED illuminator, the LEDs may also be switched off when the incandescent lamp is switched on.

Gauna, Kevin Wayne

2005-06-21T23:59:59.000Z

14

Visible Spectrum Incandescent Selective Emitter  

SciTech Connect (OSTI)

The purpose of the work performed was to demonstrate the feasibility of a novel bi-layer selective emitter. Selective emitters are incandescent radiant bodies with emissivities that are substantially larger in a selected part of the radiation spectrum, thereby significantly shifting their radiated spectral distribution from that of a blackbody radiating at the same temperature. The major research objectives involved answering the following questions: (1) What maximum VIS/NIR radiant power and emissivity ratios can be attained at 2650 K? (2) What is the observed emitter body life and how does its performance vary with time? (3) What are the design tradeoffs for a dual heating approach in which both an internally mounted heating coil and electrical resistance self-heating are used? (4) What are the quantitative improvements to be had from utilizing a bi-layer emitter body with a low emissivity inner layer and a partially transmissive outer layer? Two approaches to obtaining selective emissivity were investigated. The first was to utilize large optical scattering within an emitter material with a spectral optical absorption that is much greater within the visible spectrum than that within the NIR. With this approach, an optically thick emitter can radiate almost as if optically thin because essentially, scattering limits the distance below the surface from which significant amounts of internally generated radiation can emerge. The performance of thin emitters was also investigated (for optically thin emitters, spectral emissivity is proportional to spectral absorptivity). These emitters were fabricated from thin mono-layer emitter rods as well as from bi-layer rods with a thin emitter layer mounted on a substrate core. With an initially estimated energy efficiency of almost three times that of standard incandescent bulbs, a number of energy, economic and environmental benefits such as less energy use and cost, reduced CO{sub 2} emissions, and no mercury contamination was initially projected. The work performed provided answers to a number of important questions. The first is that, with the investigated approaches, the maximum sustained emitter efficiencies are about 1.5 times that of a standard incandescent bulb. This was seen to be the case for both thick and thin emitters, and for both mono-layer and bi-layer designs. While observed VIS/NIR ratios represent improvements over standard incandescent bulbs, it does not appear sufficient to overcome higher cost (i.e. up to five times that of the standard bulb) and ensure commercial success. Another result is that high temperatures (i.e. 2650 K) are routinely attainable without platinum electrodes. This is significant for reducing material costs. A novel dual heating arrangement and insulated electrodes were used to attain these temperatures. Another observed characteristic of the emitter was significant grain growth soon after attaining operating temperatures. This is an undesirable characteristic that results in substantially less optical scattering and spectral selectivity, and which significantly limits emitter efficiencies to the values reported. Further work is required to address this problem.

Sonsight Inc.

2004-04-30T23:59:59.000Z

15

Tungsten wire for incandescent lamps  

SciTech Connect (OSTI)

Tungsten wire for incandescent lamp filaments must operate at high temperatures and for long times. To meet these requirements, the grain morphology of the wire must be controlled to reduce the propensity for grain boundary sliding. The morphology is a function of the distribution of very small pockets of potassium in the wire and the mechanical processing from ingot to wire. The behavior of the filament is directly related to the grain morphology. This paper describes the mechanism by which the potassium is incorporated into and distributed in the ingot. The elongation and spheroidization of the bubbles during hot rolling and swaging is also examined and related to the grain morphology of wire. Some indications of the relationship between grain morphology and filament behavior are also given.

Walter, J.L.; Briant, C.L. (General Electric Corporate Research and Development, Schenectady, NY (USA))

1990-09-01T23:59:59.000Z

16

Comprehensive Pyrometry of Incandescent Multiwalled Carbon Nanotubes and Graphene in the Visible and Near Infrared  

E-Print Network [OSTI]

4.17 Image of incandescent tungsten ?to collect data from incandescent MWCNTs. An illustration ofand of Carbon at Incandescent Temper- atures,” Physical

Singer, Scott

2012-01-01T23:59:59.000Z

17

DOE Requires Manufacturer and Labeler to Cease Sale of Incandescent...  

Broader source: Energy.gov (indexed) [DOE]

Manufacturer and Labeler to Cease Sale of Incandescent Reflector Lamps DOE Requires Manufacturer and Labeler to Cease Sale of Incandescent Reflector Lamps June 24, 2010 - 2:40pm...

18

Residential Electricity Demand in China -- Can Efficiency Reverse the Growth?  

E-Print Network [OSTI]

2000: Lighting Type Incandescent Fluorescent CFL Percentagescenario, we assume that incandescent bulbs are graduallyW 60W 15W Fluorescent Lamps Incandescent Lamps CFL We then

Letschert, Virginie

2010-01-01T23:59:59.000Z

19

Energy Management A Program of Energy Conservation for the Community College Facility  

E-Print Network [OSTI]

whenever possible) Lamps Type (incandescent, fluorescent,are as follows: Lamp Type Incandescent FI uorescent Mercurylumens/watt lumens/watt Incandescent Mercury Metal Additive

Authors, Various

2011-01-01T23:59:59.000Z

20

Incandescent Lighting Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA,Fermi NationalBusiness PlanPosting of| Department ofTheseIncandescent

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Operating temperatures for a convectively cooled recessed incandescent light fixture  

SciTech Connect (OSTI)

Test results are given for the operation of a recessed incandescent light fixture intended for residential use. The fixture is labeled for use in direct contact with attic thermal insulation. Temperature control of the powered fixture is provided by convective heat transfer from the ceiling side of the fixture. The fixture was operated at power levels up to two times the rated power of 75 watts and under thermal insulations up to R-40. In all operating configurations tested the fixture surface in contact with attic insulation was found to be less than 175/sup 0/C. The observed surface temperatures are judged to be safe for operation in contact with loose-fill or batt-type insulations. It was observed that the power leads inside one fixture configuration are exposed to temperatures as high as 168/sup 0/C. The electrical insulation could, therefore, have a limited life. The properties of the internal fixture wiring were not, however, studied in detail.

Yarbrough, D.W.; Toor, I.

1980-12-01T23:59:59.000Z

22

AN ANALYTICAL AND QUANTITATIVE ANALYSIS OF THE LASER-INDUCED INCANDESCENCE OF SOOT  

E-Print Network [OSTI]

AN ANALYTICAL AND QUANTITATIVE ANALYSIS OF THE LASER-INDUCED INCANDESCENCE OF SOOT A Thesis-INDUCED INCANDESCENCE OF SOOT Approved: _________________________ Jerry M. Seitzman, Chairman

Seitzman, Jerry M.

23

Global Potential of Energy Efficiency Standards and Labeling Programs  

E-Print Network [OSTI]

lighting (replacement of incandescent lamps with CFLs) withof each type of lamp: incandescent; fluorescent tubes; andless consumptive than incandescent bulbs. Second, it impacts

McNeil, Michael A

2008-01-01T23:59:59.000Z

24

The effects of supply harmonics on the performance of compact fluorescent lamps  

SciTech Connect (OSTI)

This paper describes a performance evaluation of ten compact fluorescent lighting systems operated with sinusoidal and distorted voltage waveform conditions. The lamps were either provided with an electronic ballast, a magnetic core ballast or a magnetic core ballast with a power factor correction circuit. The test results show that the electrical performance of the compact fluorescent lamps for both sinusoidal and distorted voltage waveform operation is related to the different types of ballast used. The cost of operation of these compact fluorescent lamps was calculated and compared to the cost of a conventional 60 W incandescent lamp.

Arseneau, R.; Ouellette, M.

1993-04-01T23:59:59.000Z

25

How Energy-Efficient Light Bulbs Compare with Traditional Incandescent...  

Broader source: Energy.gov (indexed) [DOE]

could save you about 50 per year in energy costs when you replace 15 traditional incandescent bulbs in your home. Energy-efficient light bulbs are available today and could save...

26

Assessment of soot particle vaporization effects during laser-induced incandescence with  

E-Print Network [OSTI]

Assessment of soot particle vaporization effects during laser-induced incandescence with time-induced incandescence (LII) has been successfully used for soot volume fraction and particle size measurements

Hahn, David W.

27

Compact fluorescent lamp applications in luxury hotels  

SciTech Connect (OSTI)

Over the past several years, consumers, lighting designers, and energy conservationists have paid increasing attention to the special characteristics of compact fluorescent lamps (CFLs). CFLs can typically be used to replace incandescent lamps of three to four times their own wattage, and their color rendering indices (CRIs)-80 to 85-make them virtually indistinguishable from incandescents. The typical 10,0000-hour life of a CFL often makes savings in labor its most desirable feature when compared to a shorter-lived incandescent lamp.

Gilleskie, R.J.

1996-01-01T23:59:59.000Z

28

Metallic photonic-band-gap filament architectures for optimized incandescent lighting Sajeev John and Rongzhou Wang  

E-Print Network [OSTI]

Metallic photonic-band-gap filament architectures for optimized incandescent lighting Sajeev John occur 3,4 . Tra- ditionally incandescent lighting filaments, despite being driven from equilibrium the blackbody spectrum. This suggests the pos- sibility of higher efficiency incandescent lighting, through

John, Sajeev

29

Molecular Dynamics Simulations of Laser Induced Incandescence Dr. Adri van Duin  

E-Print Network [OSTI]

Molecular Dynamics Simulations of Laser Induced Incandescence (LII) Dr. Adri van Duin Associate of Engineering. Laser Induced Incandescence (LII) is a popular method to estimate the properties of soot. Molecular Dynamics Simulations of Laser-Induced Incandescence of Soot Using an Extended ReaxFF Reactive

Bjørnstad, Ottar Nordal

30

L'EMISSION ELECTRIQUE DU PLATINE INCANDESCENT DANS UNE ATMOSPHRE D'IODE  

E-Print Network [OSTI]

L'EMISSION ELECTRIQUE DU PLATINE INCANDESCENT DANS UNE ATMOSPH�RE D'IODE par M. S. KALANDYK influence devient nulle aux températures de chauffage élevées. 3. Pour une faible incandescence du platine approximativement linéaire; aux fortes incandescences, cette variation offre un caractère beaucoup plus compliqué. 1

Paris-Sud XI, Université de

31

Compact light source performance in recessed type luminaires  

SciTech Connect (OSTI)

Photometric comparisons were made with an indoor, recessed, type luminaire using incandescent, high intensity discharge and compact fluorescent lamps. The test results show substantial performance advantages, as expected, for the discharge light sources where the efficacy gains can be in the order for 400% even when including the ballast losses associated with the discharge lamps. The candlepower distribution patterns emerging from these luminaries are also different from those associated with the baseline incandescent lamps, and which are in some ways, even more desirable from a uniformity of illuminance perspective. A section on fluorescent lamp starting is also included which describes a system having excellent starting characteristics in terms of electrode starting temperature (RH/RC technique), proper operating frequency to minimize unwanted IR interactions, and satisfactory current crest factor values to help insure life performance.

Hammer, E.E.

1998-11-01T23:59:59.000Z

32

Introduction The Sun is a mass of incandescent gas  

E-Print Network [OSTI]

Chapter 1 Introduction The Sun is a mass of incandescent gas A gigantic nuclear furnace Building that our bodies contain atoms that, like most elements and their isotopes in the Solar System, were part of the molecular cloud from which the Solar System condensed, and were trapped in primitive

Nittler, Larry R.

33

Residential and Transport Energy Use in India: Past Trend and Future Outlook  

E-Print Network [OSTI]

type of lighting bulb (incandescent, fluorescent), number ofof incandescent bulbs and fluorescent tubes per household,incandescent bulbs of 60W and 2.1 fluorescent tubes of 40W

de la Rue du Can, Stephane

2009-01-01T23:59:59.000Z

34

J.-A. FLEMING. 2014 On the characteristic curves and surfaces of incandescence lamps (Courbes caractristiques des lampes incandescence) ; Phil. Mag.,  

E-Print Network [OSTI]

80 J.-A. FLEMING. 2014 On the characteristic curves and surfaces of incandescence lamps (Courbes caractéristiques des lampes à incandescence) ; Phil. Mag., 5e série, t. XIX, p. 368; I885. L'auteur étudie les résistance correspondant à la force électromotrice vo à laquelle l'incandescence commence à se produire, et r

Paris-Sud XI, Université de

35

Convection venting lensed reflector-type compact fluorescent lamp system  

DOE Patents [OSTI]

Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures. 12 figs.

Pelton, B.A.; Siminovitch, M.

1997-07-29T23:59:59.000Z

36

Energy Savings and NOx Emissions Reduction Potential from the 2012 Federal Legislation to Phase Out Incandescent Lamps in Texas  

E-Print Network [OSTI]

Lamps in Texas Description Value Reference Total Housing Units in Texas in 2013: 10,204,056 Real Estate Center, Texas A&M University3, U.S. Census Bureau4 5 Average Lighting Electricity Usage per House: 1,946 kWh/yr NREL Building America Program6... Savings in Texas: 10,424,973 MWh/yr OSD CFL Savings in Texas: 28,562 MWh/day By 2013, it is estimated that total savings of 10,424,973 MWh/yr would be achieved from replacing incandescent lamps with compact fluorescent lamps (CFL) in residential...

Liu, Zi; Baltazar, Juan Carlos; Haberl, Jeff; Soman, Rohit

37

L'MISSION LECTRIQUE DU PLATINE INCANDESCENT DANS UNE ATMOSPHRE D'IODE  

E-Print Network [OSTI]

L'�MISSION �LECTRIQUE DU PLATINE INCANDESCENT DANS UNE ATMOSPH�RE D'IODE par M. PIERRE JEZ],du platine incandescent ~dans une atmosphère d'iode en fonction : 1, de la température ; 2, du temps; 3, de électrodes, d'un grillage métallique pour éviter les influences extérieures. L'incandescence des électrodes s

Paris-Sud XI, Université de

38

LE RAYONNEMENT DES MANCHONS A INCANDESCENCE ; Par M. H. RUBENS1).  

E-Print Network [OSTI]

306 LE RAYONNEMENT DES MANCHONS A INCANDESCENCE ; Par M. H. RUBENS1). 1. - INTRODUCTION. Les remarquables propriétés du manchon à incandescence Auer ont dès l'origine excité au plus haut point l été entreprises par Langley pour la lampe à incandescence au pétrole avec l'aide de ses bolomètres

Paris-Sud XI, Université de

39

PROCD RAPIDE POUR LA PHOTOMTRIE DES BECS A INCANDESCENCE PAR LE GAZ (1) ;  

E-Print Network [OSTI]

469 PROC�D� RAPIDE POUR LA PHOTOM�TRIE DES BECS A INCANDESCENCE PAR LE GAZ (1) ; Par P. LAURIOL. Les essais des becs à incandescence par le gaz destinés à l'éclai- rage public comportent un très pendant une série de mesures. On emploie une lampe à incandescence électrique dont on #12;471 maintint la

Paris-Sud XI, Université de

40

MISSION CATHODIQUE A L'INTRIEUR DES LAMPES A INCANDESCENCE ; par M. L. HOULLEVIGUE (1).  

E-Print Network [OSTI]

523 �MISSION CATHODIQUE A L'INT�RIEUR DES LAMPES A INCANDESCENCE ; par M. L. HOULLEVIGUE (1). I. Lorsqu'on survolte fortement une lampe à incandescence à filament de charbon, par exemple en mettant sous incandescent. ' , Fic.. 1. Tous ces effets peuvent être attribués, en première analyse, aux électrons émanés du

Boyer, Edmond

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

EA-1911: Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps  

Broader source: Energy.gov [DOE]

This EA will evaluate the environmental impacts of a proposal to amend energy conservation standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps.

42

STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE AND FIELD INSPECTION CHECKLIST  

E-Print Network [OSTI]

Watts: 1. Type of luminaire (i.e.: post top, wall pack, surface, shoe box); for non-incandescent luminaires, indicate nominal lamp wattage and lamp type ( i.e.: fluorescent, incandescent, HID); ballast type. For incandescent luminaires, the lum

43

How to upgrade your incandescent light bulbs Many people are choosing replacements for their standard incandescent light bulbs to save money or energy, because they've heard of new LED  

E-Print Network [OSTI]

How to upgrade your incandescent light bulbs Many people are choosing replacements for their standard incandescent light bulbs to save money or energy, because they've heard of new LED options, or in anticipation of the phase-out of standard incandescent bulbs in the U.S. starting in 2012. If you've shopped

Bystroff, Chris

44

Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings  

E-Print Network [OSTI]

Appliance type Standard technology DC-internal best technology Lighting Incandescent, fluorescent, LED Incandescent Electronic Heating Heater Electric resistance Cooling Motor (& compressor,

Garbesi, Karina

2012-01-01T23:59:59.000Z

45

Apparatus to facilitate lengthening the life of incandescent lamps  

SciTech Connect (OSTI)

An energizing circuit is described for an incandescent bulb comprising a transformer having a primary winding connectable to an AC mains source and first and second secondary windings for producing first and second voltages. The first secondary winding is connected to an input of a first full-wave rectifier means and the second secondary winding is connected to an input of a second full-wave rectifier means, the full-wave rectifier means having outputs connected in parallel across the bulb. The first voltage is sufficient to fully illuminate the bulb and the second voltage is sufficient to maintain the bulb warm but with little or no light output, a first switch being connected between the first secondary winding and the first rectifier means whereby, when the first switch is open, the bulb is energized solely by the second voltage.

Spissinger, F.H.

1987-03-17T23:59:59.000Z

46

Energy Consumption, Efficiency, Conservation, and Greenhouse Gas Mitigation in Japan's Building Sector  

E-Print Network [OSTI]

and a washroom with bulb-type fluorescent lamps, (5) closingusing incandescent bulbs to fluorescent lamps. This switch

2006-01-01T23:59:59.000Z

47

L'MISSION LECTRIQUE DU TUNGSTNE INCANDESCENT DANS UNE ATMOSPHRE D'IODE.  

E-Print Network [OSTI]

L'�MISSION �LECTRIQUE DU TUNGST�NE INCANDESCENT DANS UNE ATMOSPH�RE D'IODE. par S. KALANDYK'émission négative du tungstène; l'influence de l'iode est prépondérante aux basses températures d'incandescence 3. L vapeur d'iode augmente l'émis sion électrique négative du platine incandescent. L'influence de l'iode se

Paris-Sud XI, Université de

48

Residential and Transport Energy Use in India: Past Trend and Future Outlook  

E-Print Network [OSTI]

type of lighting bulb (incandescent, fluorescent), number ofhouseholds possessed 3.2 incandescent bulbs of 60W and 2.1areas versus only 2.1 incandescent bulbs of 60W and 1.5

de la Rue du Can, Stephane

2009-01-01T23:59:59.000Z

49

Thermally efficient compact fluorescent fixture systems  

SciTech Connect (OSTI)

Compact fluorescent lamps that can be inserted into conventional light fixtures are rapidly gaining acceptance as both a viable retrofit and new design approach to reducing lighting loads. Ideally, the compact fluorescent lamp should have the same light output as the incandescent lamp it replaces, but overheating inside typically small enclosed fixtures can reduce lumen output and hence lighting fixture efficiency by 15 to 20 percent. Fortunately, simple fixture modifications can erase this efficiency penalty, so that the full efficiency benefit of replacing incandescent lamps with fluorescent lamps can be realized. The paper describes such modifications and presents experimental data documenting the potential efficiency enhancement associated with thermal control systems. 4 refs., 7 figs.

Siminovitch, M.J.; Rubinstein, F.M.; Packer, M.

1991-04-01T23:59:59.000Z

50

Energy-efficient compact screw-in fluorescent lamp. Final report  

SciTech Connect (OSTI)

A compact fluorescent lamp has been designed and constructed which can replace an incandescent lamp. The lamp is slightly larger than a standard lamp (8 3/4 in. x 3 1/4 in.), but is designed to fit a majority of portable lamp applications. This version, with a core-coil ballast, results in a system efficacy of 54 lumens per watt, with a light output of more than 1800 lumens. This compares favorably with a 100-watt incandescent (17.5 lumens per watt and 1750 lumens light output). The color temperature of 3000/sup 0/K is compatible with an incandescent lamp (2800/sup 0/K). The color rendition index (CRI) is 84. With a solid-state ballast, the efficacy and light output could be increased by 20% (65 l/w, 2200 lumens) and could provide a direct replacement for a three-way, 150-watt incandescent lamp (15 l/w, 2200 lumens).

Morton, E.W.

1982-11-01T23:59:59.000Z

51

Fluorescent properties of c-type cytochromes reveal their potential role as an extracytoplasmic electron  

E-Print Network [OSTI]

via fluorescence microscopy, and the cyto- chromes in a G. sulfurreducens biofilm, remotely excited communities have indi- cated that Geobacter species are the predominant metal-reducing microorganisms

Lovley, Derek

52

Table Set-up with Materials near Lamp Stand (below) Target Audience: Parents of elementary school students (grades 3-6) and Middle and High School Students  

E-Print Network [OSTI]

spectrum with different light sources; compact fluorescent, LED, incandescent. 5. Discuss light bulb. Observe difference of color spectrum with different light sources; compact fluorescent, LED, incandescent type of bulb at different horizontal level. Electromagnetic Spectrum handouts that includes spectrum

Linhardt, Robert J.

53

Perceptions of compact fluorescent lamps in the residential market  

SciTech Connect (OSTI)

Compact fluorescent lamps offer significant energy savings over other forms of residential lighting and last up to 10 times longer than conventional incandescent bulbs. In order to better understand existing barriers to acceptance and future opportunities for growth of compact fluorescent lighting in the residential retrofit sector, a three stage research project was designed and conducted by MACRO Consulting, Inc. Assessment of whether or not the benefits of compact fluorescent lamps are sufficient to overcome price resistance was one of the major purposes of this project. Residential customers were interviewed in focus group sessions to help determine key issues and motivating forces in the lighting/energy saving/cost saving equation. Residential customers in 5 major market areas were contacted by telephone, and data about their awareness, knowledge and use of compact fluorescent lighting were collected. These customers also participated in an attribute rating exercise in which compact fluorescent lamps were compared with fluorescent tubes and incandescent bulbs on a series of product attributes. A price elasticity exercise was also conducted. Teleconferences with retailers of compact fluorescent lamps were conducted in order to explore their knowledge of and attitudes towards compact fluorescent lamps. Customers agree that energy savings and longer life are both positive attributes for residential lighting products, but they are not yet ready to make the switch away from inexpensive, versatile and readily available incandescent bulbs to compact fluorescent lamps. Compact fluorescent lamps are rated poorly (even by satisfied'' users) on each of seven positive attributes of home lighting. Major barriers to increased use of compact fluorescent lamps include price, convenience, and performance. Prices above $10 are considered outrageous''. Product improvements are needed for appearance, light output and versatility.

Weiner, J.; Campbell, C.J. (Macro Consulting, Inc., Mountain View, CA (United States))

1992-07-01T23:59:59.000Z

54

Creating markets for new products to replace incandescent lamps: The international experience  

SciTech Connect (OSTI)

Since the summer of 1995, several organizations have been in pursuit of what many consider the Holy Grail of lighting technology--a low-cost, drop-in, energy-efficient replacement for the incandescent lamp. This paper summarizes the international experience in attempting to catalyze the commercialization of a mass-market, replacement product that could have major impact on residential lighting energy consumption in US and EU homes. The technology procurement effort was originally spearheaded by US Federal Government through a loose collaboration between the Department of Defense (DoD), the Environmental Protection Agency (EPA) and the Department of Energy (DOE). The DoD agreed to serve as the anchor buyer for a low-cost, drop-in replacement product for standard-sized light bulbs that provide at least 30 percent energy savings compared to traditional incandescent lamps. In parallel to the US effort, the International Energy Agency launched a co-operative technology procurement effort by assembling large buyers' groups in Finland, the Netherlands, Sweden, and the United Kingdom to pull a similar efficient lighting product into the European market. The lukewarm response from lamp manufacturers to these two technology procurement efforts illustrates the challenges of transforming residential lighting from incandescent to efficient lighting.

Rubinstein, F.; Borg, N.; Horowitz, N.; Narel, T.; Morehouse, E.T. Jr.

1998-07-01T23:59:59.000Z

55

A theoretical study of the incandescent filament lamp performance under voltage flicker  

SciTech Connect (OSTI)

Incandescent filament lamp flicker, produced by voltage fluctuation, is a power quality problem that caused engineering concern since the onset of electrical illumination technology. The flicker phenomenon was analyzed and explained in early studies. Standards dealing with acceptable flicker levels are well known, nevertheless, today the discussion about flicker continues to be a top priority topic due to the fact that steady-state and transient voltage waveform distortion is a growing problem in low and medium voltage systems. In many situations voltage flicker is caused by subharmonics and interharmonics of voltage. Cycloconverters, welders and arc furnaces, eccentrically operating tools and integral cycle controlled power equipment are notorious for producing voltage flicker. The goal of this paper is to provide solid mathematical basis for the analytical modeling of incandescent filament lamp flicker when the voltage is nonsinusoidal. A mathematical model that enables the evaluation of the luminous flux modulation caused by noninteger harmonics (subharmonics and interharmonics) is presented. Three situations are detailed: square-wave voltage modulation, sinusoidal modulation and the case of noninteger harmonics with nearly contiguous frequencies.

Peretto, L. [Univ. of Bologna (Italy)] [Univ. of Bologna (Italy); Emanuel, A.E. [Worcester Polytechnic Inst., MA (United States)] [Worcester Polytechnic Inst., MA (United States)

1997-01-01T23:59:59.000Z

56

Linings with optimum heat-emission surfaces for cars receiving and transporting incandescent coke  

SciTech Connect (OSTI)

The least reliable components of the cars which receive and transport incandescent coke are the lining plates. This applies to both the quenching cars used for wet quenching and the hot-coke cars used in the dry cooling process. Technical advances have been described whereby the life of car linings is prolonged by increasing heat emission from the lining plate surfaces. As the heat emission level is enhanced the mean plate temperature is lowered and the lining life thereby prolonged; moreover, the between-servicings period is prolonged. This involves providing fins on the non-working (outer) plate surfaces. The problem of optimizing the size and shape of the fins with reference to heat emission remains unsolved: the requirement is maximum heat emission from plates of a given weight, or conversely minimum plate weight for a given heat emission level. 6 refs., 3 figs.

Kotlyar, B.D.; Pleshkov, P.I.; Gadyatskii, V.G. [and others

1992-12-31T23:59:59.000Z

57

Assessing the Performance of 5mm White LED Light Sources for Developing-Country Applications  

E-Print Network [OSTI]

performance variations. Incandescent and fluorescent lightbetter than the common incandescent lamp. Off-grid lighting

Mills, Evan

2007-01-01T23:59:59.000Z

58

Acting Globally: Potential Carbon Emissions Mitigation Impacts from an International Standards and Labelling Program  

E-Print Network [OSTI]

both fluorescent and incandescent), standby power (forFluorescent Tubes Incandescent Lamps All % of CFL variableRefrigerator Savings Incandescent Lamp Savings Fluorescent

Letschert, Virginie E.

2010-01-01T23:59:59.000Z

59

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network [OSTI]

38 TWh, 10% of which was for incandescent lighting (Fig. 3).The electricity consumed in incandescent lighting can be300 and 400 million incandescent lamps in the country. Let

Gadgil, A.J.

2008-01-01T23:59:59.000Z

60

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network [OSTI]

also additional benefits from avoided costs of environmentalpremium for India)) - (avoided annual cost of incandescents)electricity) + (avoided annual cost of incandescents) - (

Gadgil, A.J.

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

ENERGY EFFICIENT LIGHTING PROGRAM. CHAPTER FROM THE ENERGY AND ENVIRONMENT DIVISION ANNUAL REPORT 1979  

E-Print Network [OSTI]

socket for a standard incandescent lamp. Once the diffuserwhether the lamp is fluorescent or incandescent, Comparedto the incandescent lamp, the circline fluorescent improves

Berman, S.

2013-01-01T23:59:59.000Z

62

Synthesis and luminescence properties of rare earth activated phosphors for near UV-emitting LEDs for efficacious generation of white light  

E-Print Network [OSTI]

lighting using incandescent lights and fluorescent lamps, asenergy used for the incandescent lamp is wasted as infraredsource to replace incandescent and fluorescent lighting [2].

Han, Jinkyu

2013-01-01T23:59:59.000Z

63

Assessing the Performance of LED-Based Flashlights Available in the Kenyan Off-Grid Lighting Market  

E-Print Network [OSTI]

have largely displaced incandescent flashlights in retailinvolving the use of incandescent lighting, unless there areFluorescent Flashlight C Incandescent SPX 50 Fluorescent y x

Tracy, Jennifer

2010-01-01T23:59:59.000Z

64

,,,"Incandescent","Standard Fluorescent","Compact Fluorescent","High-Intensity Discharge","Halogen"  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQProved Reserves, Reserves Changes, and Production" ,"Click worksheet name or tabUpcoming8. Energy38.

65

,,,"Incandescent","Standard Fluorescent","Compact Fluorescent","High-Intensity Discharge","Halogen"  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQProved Reserves, Reserves Changes, and Production" ,"Click worksheet name or tabUpcoming8.

66

Comparison of 60-Hz electric fields and incandescent light as aversive stimuli controlling the behavior of rats  

SciTech Connect (OSTI)

Rats were exposed to two procedures which enabled them to press a lever to turn off a 90 or 100 kV/m 60-Hz electric field or, later in the study, illumination from an incandescent lamp. Under one procedure, a response turned off the stimulus for a fixed duration, after which the stimulus was turned on again. A response during the off-period restarted the fixed duration. None of the rats turned the field off reliably. Next, under an alternative procedure, pressing one lever turned the field off; pressing the other lever turned it back on; responding under those conditions differed little from that seen at 0 kV/m. Under both procedures, when illumination from an incandescent lamp served as the stimulus, each rat did turn the stimulus off, and performances varied with stimulus intensity. The results show that a 100 kV/m 60-Hz electric field is not sufficient to function as an aversive stimulus under two procedures where illumination from a lamp does function as an aversive stimulus.

Stern, S.; Laties, V.G.

1989-01-01T23:59:59.000Z

67

Comparison of Test Procedures and Energy Efficiency Criteria in Selected International Standards and Labeling Programs for Clothes Washers, Water Dispensers, Vending Machines and CFLs  

E-Print Network [OSTI]

top_runner//tr_fluorescent_light_bulb_jul.2009.pdf NiskinSubcommittee Final Report (bulb type fluorescent lamp). ”Fluorescent Lamps (CFLs) are an efficient lighting alternative to traditional incandescent light bulbs

Fridley, David

2010-01-01T23:59:59.000Z

68

Theoretical and experimental investigations into the particular features of the process of converting coal gas hydrocarbons on incandescent coke  

SciTech Connect (OSTI)

The prospects of the use of reducing gases in ferrous metallurgy and the possibilities for using them as a basis for coke production have been presented by the authors of the present article in the past. In the present report, the authors present certain results of theoretical and experimental investigations into the process of converting coal gas hydrocarbons on incandescent coke. The modification of the present-day method of thermodynamically calculating stable compositions of coking products, which was developed by the authors, has made it possible to apply it to specific chemical systems and process conditions not met with before, such as the conversion of hydrocarbons in mixtures of actual industrial gases (coal gas and blast furnace gas) in the presence of carbon and considerable amounts of hydrogen.

Zubilin, I.G.; Umanskii, V.E.

1984-01-01T23:59:59.000Z

69

Zinc Oxide and Nitride Nanowire Based Light Emitting Diodes  

E-Print Network [OSTI]

only be able to find incandescent lightbulbs and fluorescent10: Output spectra of incandescent light bulb, fluorescentemission spectra. The incandescent light bulb for example

Lai, Elaine Michelle

2009-01-01T23:59:59.000Z

70

Estimate of Technical Potential for Minimum Efficiency Performance Standards in 13 Major World Economies  

E-Print Network [OSTI]

for typical wattage of incandescent bulbs and hours of usagefor which we assume that incandescent bulbs gradually getsimilar to that of incandescent or fluorescent bulbs. These

Letschert, Virginie

2013-01-01T23:59:59.000Z

71

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2011  

E-Print Network [OSTI]

Fluorescent Lamps and Incandescent Reflector Lamps EPACTBallasts and Fixtures General Service Incandescent Lamps,Intermediate Base Incandescent Lamps and Candelabra Base

Meyers, Stephen

2013-01-01T23:59:59.000Z

72

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 through 2012  

E-Print Network [OSTI]

Fluorescent Lamps and Incandescent Reflector Lamps EPACTBallasts and Fixtures General Service Incandescent Lamps,Intermediate Base Incandescent Lamps and Candelabra Base

Meyers, Stephen

2013-01-01T23:59:59.000Z

73

Controls for Solid-State Lighting  

E-Print Network [OSTI]

very high would replace incandescent and halogen A modernmotion sensor, the incandescent lamp switches on providing awork with fluorescent and incandescent lighting as well as

Rubinstein, Francis

2007-01-01T23:59:59.000Z

74

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2010  

E-Print Network [OSTI]

Fluorescent Lamps and Incandescent Reflector Lamps MediumBallasts and Fixtures General Service Incandescent Lamps,Intermediate Base Incandescent Lamps and Candelabra Base

Meyers, Stephen

2013-01-01T23:59:59.000Z

75

Managing Your Energy: An ENERGY STAR(R) Guide for Identifying Energy Savings in Manufacturing Plants  

E-Print Network [OSTI]

fluorescent (CFL), and incandescent lights are typicallyhours) Applications Incandescent Task Halogen Task CFL TaskCenter of Wisconsin. Replace incandescent lamps with compact

Worrell, Ernst

2010-01-01T23:59:59.000Z

76

Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings  

E-Print Network [OSTI]

52LPW assuming 80% incandescent @14LPW goes to CFL @52LPWthan the traditional incandescent lighting it is replacingbest technology Lighting Incandescent, fluorescent, LED

Garbesi, Karina

2012-01-01T23:59:59.000Z

77

Design and Predictive Control of a Net Zero Energy Home  

E-Print Network [OSTI]

the same amount of light as traditional incandescent bulbs with less energy. Incandescent bulbs are inherently inefficient as most of the energy they consume goes towards heat generation. Compact fluorescent (CFL) and light emitting diode (LED) bulbs... as heat [1]. Compact fluorescent lamps (CFLs) and Light Emitting Diodes (LEDs) were analyzed in comparison with incandescent lamps. To determine the most energy efficient bulb, energy consumption for each type of bulb is needed. To do this, the amount...

Morelli, F.; Abbarno, N.; Boese, E.; Bullock, J.; Carter, B.; Edwards, R.; Lapite, O.; Mann, D.; Mulvihill, C.; Purcell, E.; Stein, M. IV; Rasmussen, B. P.

2013-01-01T23:59:59.000Z

78

Optimized Magnetic Components Improve Efficiency of Compact Fluorescent Lamps  

E-Print Network [OSTI]

xtures (designed for incandescent bulbs) has allowed residential and small commercial electric customers of incandescent lamps and last 10 times longer [1]. High-frequency electronic ballasts are used to power CFLs

79

Development of a fluorescent cryocooler  

SciTech Connect (OSTI)

Recent work at Los Alamos National Laboratory has demonstrated the physical principles for a new type of solid-state cryocooler based on anti-Stokes fluorescence. Design studies indicate that a vibration-free, low-mass ``fluorescent cryocooler`` could operate for years with efficiencies and cooling powers comparable to current commercial systems. This paper presents concepts for a fluorescent cryocooler, design considerations and expected performance.

Edwards, B.C.; Buchwald, M.I.; Epstein, R.I.; Gosnell, T.R.; Mungan, C.E.

1995-10-01T23:59:59.000Z

80

THE HISTORY AND TECHNICAL EVOLUTION OF HIGH FREQUENCY FLUORESCENT LIGHTING  

E-Print Network [OSTI]

B L U E , G R E E N , INCANDESCENT FORM OF LAMPS OF VARIOUSTHE E F F I C I E N C Y INCANDESCENT A P P L I C A T I O N SI M E S , DEPENDING THE THE INCANDESCENT GENERAL LAMPS. THE

Campbell, John H.

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines  

SciTech Connect (OSTI)

We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

Yoon, Phil S. [Experimental Facility Division, NSLS-II, Brookhaven National Laboratory, Upton, NY 11973 (United States); Siddons, D. Peter [Experimental Systems, NSLS, Brookhaven National Laboratory, Upton, NY 11973 (United States)

2010-06-23T23:59:59.000Z

82

Zinc Oxide and Nitride Nanowire Based Light Emitting Diodes  

E-Print Network [OSTI]

of incandescent light bulb, fluorescent lamp, and blue lightof incandescent light bulb, fluorescent lamp, and blue lightincandescent bulb and is on the same order as fluorescent

Lai, Elaine Michelle

2009-01-01T23:59:59.000Z

83

Sleep, mood, and circadian responses to bright green light during sleep  

E-Print Network [OSTI]

white light from fluorescent bulbs, as point sources mightthan incandescent bulbs. Also, fluorescent light is easier

Grandner, Michael Andrew

2007-01-01T23:59:59.000Z

84

Electrical and Optical Enhancement in Internally Nanopatterned Organic Light-Emitting Diodes  

E-Print Network [OSTI]

incandescent bulbs and fluorescent bulbs). Solid-stateindex (CRI) than fluorescent bulbs. Common examples where

Fina, Michael Dane

2012-01-01T23:59:59.000Z

85

High Hats, Swiss Cheese, and Fluorescent Lighting?  

SciTech Connect (OSTI)

For DOE, PNNL is conducting a competitive procurement to promote market introduction of new residential recessed downlights (also known as ''recessed cans'' or ''high hats'') that are airtight, rated for insulated ceilings, and hard-wired for CFLs. This paper discusses the potential energy savings of new high-efficiency downlights, and the results of product testing to date. Recessed downlights are the most popular residential lighting fixtures in the United States, with 21.7 million fixtures sold in 2000. An estimated 350 million are currently installed in American homes. Recessed cans are relatively inexpensive, and provide an unobtrusive, directed source of light for kitchens, hallways, and living rooms. Recessed cans are energy-intensive in three ways. First, virtually all recessed cans currently installed in the residential sector use incandescent light sources, typically reflector-type lamps drawing 65-150 watts. Second, heat from incandescent lamps adds to air-conditioning loads. Third, most installed recessed cans are not airtight, so they allow conditioned air to escape from the living area into unconditioned spaces such as attics. Addressing both lighting energy use and air leakage in recessed cans has proven challenging. Lighting energy efficiency is greatly improved by using CFLs. Air leakage can be addressed by making fixtures airtight. But when CFLs are used in an airtight recessed can, heat generated by the lamp and ballast is trapped within the fixture. Excessive heat causes reduced light output and shorter lifespan of the CFL. The procurement was designed to overcome these technical challenges and make new products available in the marketplace.

McCullough, Jeffrey J.; Gordon, Kelly L.

2002-08-30T23:59:59.000Z

86

NEXT GENERATION ENERGY EFFICIENT FLUORESCENT LIGHTING PRODUCT  

SciTech Connect (OSTI)

This is the Final Report of the Next-Generation Energy Efficient Fluorescent Lighting Products program, Department of Energy (DOE). The overall goal of this three-year program was to develop novel phosphors to improve the color rendition and efficiency of compact and linear fluorescent lamps. The prime technical approach was the development of quantum-splitting phosphor (QSP) to further increase the efficiency of conventional linear fluorescent lamps and the development of new high color rendering phosphor blends for compact fluorescent lamps (CFLs) as potential replacements for the energy-hungry and short-lived incandescent lamps in market segments that demand high color rendering light sources. We determined early in the project that the previously developed oxide QSP, SrAl{sub 12}O{sub 19}:Pr{sup 3+}, did not exhibit an quantum efficiency higher than unity under excitation by 185 nm radiation, and we therefore worked to determine the physical reasons for this observation. From our investigations we concluded that the achievement of quantum efficiency exceeding unity in SrAl{sub 12}O{sub 19}:Pr{sup 3+} was not possible due to interaction of the Pr{sup 3+} 5d level with the conduction band of the solid. The interaction which gives rise to an additional nonradiative decay path for the excitation energy is responsible for the low quantum efficiency of the phosphor. Our work has led to the development of a novel spectroscopic method for determining photoionzation threshold of luminescent centers in solids. This has resulted in further quantification of the requirements for host phosphor lattice materials to optimize quantum efficiency. Because of the low quantum efficiency of the QSP, we were unable to demonstrate a linear fluorescent lamp with overall performance exceeding that of existing mercury-based fluorescent lamps. Our work on the high color rendering CFLs has been very successful. We have demonstrated CFLs that satisfies the EnergyStar requirement with color rendering index (CRI) greater than 90; the CRI of current commercial CFLs are in the low 80s. In this report we summarize the technical work completed under the Program, summarize our findings about the performance limits of the various technologies we investigated, and outline promising paths for future work.

Alok Srivastava; Anant Setlur

2003-04-01T23:59:59.000Z

87

Compact Fluorescent Plug-In Ballast-in-a-Socket  

SciTech Connect (OSTI)

The primary goal of this program was to develop a ballast system for plug-in CFLs (compact fluorescent lamps) that will directly replace standard metal shell, medium base incandescent lampholders (such as Levition No. 6098) for use with portable lamp fixtures, such as floor, table and desk lamps. A secondary goal was to identify a plug-in CFL that is optimized for use with this ballast. This Plug-in CFL Ballastin-a-Socket system will allow fixture manufacturers to easily manufacture CFL-based high-efficacy portable fixtures that provide residential and commercial consumers with attractive, cost-effective, and energy-efficient fixtures for use wherever portable incandescent fixtures are used today. The advantages of this proposed system over existing CFL solutions are that the fixtures can only be used with high-efficacy CFLs, and they will be more attractive and will have lower life-cycle costs than screw-in or adapter-based CFL retrofit solutions. These features should greatly increase the penetration of CFL's into the North American market. Our work has shown that using integrated circuits it is quite feasible to produce a lamp-fixture ballast of a size comparable to the current Edison-screw 3-way incandescent fixtures. As for price points for BIAS-based fixtures, end-users polled by the Lighting Research Institute at RPI indicated that they would pay as much as an additional $10 for a lamp containing such a ballast. The ballast has been optimized to run with a 26 W amalgam triple biax lamp in the base-down position, yet can accept non-amalgam versions of the lamp. With a few part alterations, the ballast can be produced to support 32 W lamps as well. The ballast uses GE's existing L-Comp[1] power topology in the circuit so that the integrated circuit design would be a design that could possibly be used by other CFL and EFL products with minor modifications. This gives added value by reducing cost and size of not only the BIAS, but also possibly other integral CFL and future dimmable integral and plug-in versions of the EFL products.

Rebecca Voelker

2001-12-21T23:59:59.000Z

88

Market Trial: Selling Off-Grid Lighting Products in Rural Kenya  

E-Print Network [OSTI]

people reported using an incandescent dry cell flashlightpurchasers. Type of Light  Incandescent  LED dry cell  LED LED rechargeable, and incandescent dry cell flashlights were

Tracy, Jennifer

2012-01-01T23:59:59.000Z

89

The Boom of Electricity Demand in the Residential Sector in the Developing World and the Potential for Energy Efficiency  

E-Print Network [OSTI]

for fluorescent and incandescent lamps. Estimates of thein Table 3. Table 3 – Incandescent, Fluorescent and CFL lampthe surveys is 60W for incandescent bulb, 15W for CFLs and

Letschert, Virginie

2010-01-01T23:59:59.000Z

90

Bottom-Up Energy Analysis System - Methodology and Results  

E-Print Network [OSTI]

Documents U.S. Rulemaking Documents TSL 4 PHP IncandescentLamps Incandescent Lamps Fluorescent Lamp Ballasts kWh/yrand T5 fluorescent tubes, incandescent lamps, CFLs, Halogen

McNeil, Michael A.

2013-01-01T23:59:59.000Z

91

Type of Space Bulb Type #/House Fixture Style Greenhouse #  

E-Print Network [OSTI]

841 360 8 F 32 T8/TL 841 360 9 F 32 T8/TL 841 360 MTPS 216 Ch. 1 F 72 T12 CW/VHO 72 1 Incandescent 60w 72 2 F 72 T12 CW/VHO 72 2 Incandescent 60w 72 5 F 72 T12 CW/VHO 72 5 Incandescent 60w 72 10 F 72 T12 CW/VHO 72 10 Incandescent 60w 72 #12;DR 1009 Ch. 27 F 032/431 4 Seed Chamber Ch. 28 F40T12/ADV 41 6

Pawlowski, Wojtek

92

EA-1664: Final Environmental Assessment  

Broader source: Energy.gov [DOE]

10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps

93

Sustainable LED Fluorescent Light Replacement Technology  

SciTech Connect (OSTI)

Ilumisys and the National Center for Manufacturing Sciences (NCMS) partnered on a three-year project awarded by the United States (U.S.) Department of Energy (DOE), to quantify the impacts of LED lamps, incandescent lamps and fluorescent benchmark lamps over a product lifecycle – i.e. to develop a sustainable design and manufacturing strategy that addresses product manufacturing, use, recycling and disposal scenarios for LED-based lighting. Based on the knowledge gained from extensive product tear-down studies of fluorescent and screw-in lighting products, lifecycle assessment tools, and accelerated lifecycle testing protocols, an interactive Sustainable LED Design Guide has been developed to aid architectural and lighting designers and engineers in making design decisions that consider three important environmental impacts (greenhouse gas emissions, energy use and mercury emission) across all phases of the life of an LED lighting product. Critical information developed for the lifecycle analysis and product feature comparisons is the useful life of the lighting product as well as its performance. The Design Guide is available at www.ncms.org, and was developed based on operational and durability testing of a variety of lighting products including power consumption, light output, and useful life of a lamp in order to allow a more realistic comparison of lamp designs. This report describes the main project tasks, results and innovative features of the lifecycle assessment (LCA)-based design tools, and the key considerations driving the sustainable design of LED lighting systems. The Design Guide incorporates the following three novel features for efficiently evaluating LED lighting features in value-chains: • Bill-of-Materials (BOM) Builder – Designers may import process data for each component and supply functional data for the product, including power, consumption, lumen output and expected useful life. • Environmental Impact Review – Designs are comparable across lifecycle phases, subsystems, and environmental impact category, and can be normalized to a userdefined functional unit. • Drill-down Review – These provide an indepth look at individual lamp designs with the ability to review across subsystem or lifecycle phase.

None

2011-06-30T23:59:59.000Z

94

Spatial assessment of net mercury emissions from the use of fluorescent bulbs  

SciTech Connect (OSTI)

While fluorescent lighting is an important technology for reducing electrical energy demand, mercury used in the bulbs is an ongoing concern. Using state and country level data, net emissions of mercury from the marginal use of fluorescent lightbulbs are examined for a base year of 2004 for each of the 50 United States and 130 countries. Combustion of coal for electric power generation is generally the largest source of atmospheric mercury pollution; reduction in electricity demand from the substitution of incandescent bulbs with fluorescents leads to reduced mercury emissions during the use of the bulb. This analysis considers the local mix of power sources, coal quality, thermal conversion efficiencies, distribution losses, and any mercury control technologies that might be in place. Emissions of mercury from production and end-of-life treatment of the bulbs are also considered, providing a life-cycle perspective. Net reductions in mercury over the entire life cycle range from -1.2 to 97 mg per bulb depending on the country. The consequences for atmospheric mercury emissions of several policy scenarios are also discussed. 46 refs., 4 figs., 3 tabs.

Matthew J. Eckelman; Paul T. Anastas; Julie B. Zimmerman [Yale University, New Haven, CT (United States). Department of Chemical Engineering

2008-11-15T23:59:59.000Z

95

Incandescent Lighting | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power.pdf11-161-LNG | Department ofHTS CableDepartment ofDepartment ofDepartmentInauguration

96

Fluorescent Tube Lamps  

Broader source: Energy.gov [DOE]

FEMP temporarily suspended its energy efficiency requirements for fluorescent tube lamps as it evaluates the market impact of the pending 2012 minimum efficiency standards for fluorescent lamps. The program will issue updated energy efficiency requirements when the market distribution of this product category stabilizes and when doing so has the potential to result in significant Federal energy savings.

97

Fluorescent filtered electrophosphorescence  

DOE Patents [OSTI]

The present invention relates to organic light emitting devices (OLEDs), and more specifically to OLEDS that emit light using a combination of fluorescent emitters and phosphorescent emitters for the efficient utilization of all of the electrically generated excitons.

Forrest, Stephen (Ann Arbor, MI); Sun, Yiru (Princeton, NJ); Giebink, Noel (Ann Arbor, MI); Thompson, Mark E. (Anaheim Hills, CA)

2010-08-03T23:59:59.000Z

98

Fluorescent filtered electrophosphorescence  

DOE Patents [OSTI]

The present invention relates to organic light emitting devices (OLEDs), and more specifically to OLEDS that emit light using a combination of fluorescent emitters and phosphorescent emitters for the efficient utilization of all of the electrically generated excitons.

Forrest, Stephen R. (Princeton, NJ); Sun, Yiru (Princeton, NJ); Giebink, Noel (Princeton, NJ); Thompson, Mark E. (Anaheim Hills, CA)

2009-01-06T23:59:59.000Z

99

Fluorescence analyzer for lignin  

SciTech Connect (OSTI)

An apparatus for measuring lignin concentration with time resolved fluorescence in an undiluted wood pulp or black liquor sample, on a real-time, in situ basis is described, comprising: light source means for applying excitation light pulses at a selected wavelength and at known time intervals to the undiluted sample for causing the lignin concentration to produce fluorescent emission light with a fluorescence intensity that monotonically decreases in a quenched fluorescence regime; light detector means for measuring the emission light at the known time intervals and establishing signals indicative thereof; switching means for turning said light detector means on at precise specified time intervals after each excitation light pulse; and signal processing means connected to the light source means and the light detector means for comparing intensities of the emission light from the lignin in the quenched fluorescence regime to the intensities of the excitation light pulses on a time resolved basis for providing a measurement of the lignin concentration in the undiluted sample as a function of the time resolved emission light intensity.

Berthold, J.W.; Malito, M.L.; Jeffers, L.

1993-06-01T23:59:59.000Z

100

Fluorescent image tracking velocimeter  

DOE Patents [OSTI]

A multiple-exposure fluorescent image tracking velocimeter (FITV) detects and measures the motion (trajectory, direction and velocity) of small particles close to light scattering surfaces. The small particles may follow the motion of a carrier medium such as a liquid, gas or multi-phase mixture, allowing the motion of the carrier medium to be observed, measured and recorded. The main components of the FITV include: (1) fluorescent particles; (2) a pulsed fluorescent excitation laser source; (3) an imaging camera; and (4) an image analyzer. FITV uses fluorescing particles excited by visible laser light to enhance particle image detectability near light scattering surfaces. The excitation laser light is filtered out before reaching the imaging camera allowing the fluoresced wavelengths emitted by the particles to be detected and recorded by the camera. FITV employs multiple exposures of a single camera image by pulsing the excitation laser light for producing a series of images of each particle along its trajectory. The time-lapsed image may be used to determine trajectory and velocity and the exposures may be coded to derive directional information.

Shaffer, Franklin D. (Library, PA)

1994-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

DSM Electricity Savings Potential in the Buildings Sector in APP Countries  

E-Print Network [OSTI]

150 million compact fluorescent light bulbs in 2010. (ChinaCleaners Incandescent Bulbs Fluorescent Lamps Ballasts forincandescent bulbs with compact fluorescent lamps. Consumers

McNeil, MIchael

2011-01-01T23:59:59.000Z

102

Fluorescent Protein Applications in Microscopy  

E-Print Network [OSTI]

. The Identification of Green Fluorescent Protein III. Formation of the GFP Chromophore IV. The Structure of GFP V environment. II. The Identification of Green Fluorescent Protein The isolation of green fluorescent protein of Aequorea, Shimomura et al. noted that the lumines- cence from aequorin was blue rather than the green

Straight, Aaron

103

Recommendations to Reduce Light Pollution and Energy Costs on the  

E-Print Network [OSTI]

(PAT18, PAT19, PAT27, PAT28, PAT29 - CL14): #12;· Change class #15, and class #20, incandescent bulbs with exterior fluorescent bulbs: · Change class #18 incandescent flood-light bulbs with fluorescent flood

104

Renewable Surface Fluorescence Sandwich Immunoassay Biosensor...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Renewable Surface Fluorescence Sandwich Immunoassay Biosensor for Rapid Sensitive Botulinum Toxin Detection in an Automated Renewable Surface Fluorescence Sandwich Immunoassay...

105

The Air-Fluorescence Yield  

E-Print Network [OSTI]

Detection of the air-fluorescence radiation induced by the charged particles of extensive air showers is a well-established technique for the study of ultra-high energy cosmic rays. Fluorescence telescopes provide a nearly calorimetric measure of the primary energy. Presently the main source of systematic uncertainties comes from our limited accuracy in the fluorescence yield, that is, the number of fluorescence photons emitted per unit of energy deposited in the atmosphere by the shower particles. In this paper the current status of our knowledge on the fluorescence yield both experimental an theoretical will be discussed.

F. Arqueros; F. Blanco; D. Garcia-Pinto; M. Ortiz; J. Rosado

2008-07-30T23:59:59.000Z

106

CX-011406: Categorical Exclusion Determination | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Categorical Exclusion Determination Notice of Proposed Rulemaking for Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps...

107

4024 Inorg. Chem. 1987, 26, 4024-4029 Contribution from the Departments of Chemistry, Colgate University, Hamilton, New York 13346,  

E-Print Network [OSTI]

and laboratory fluorescent light and during nights to light from a 150-W incandescent bulb 20 cm from the pair

Herbert, Bruce

108

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in China  

E-Print Network [OSTI]

Commercial and Industrial End Uses Incandescent Lamps Refrigerators Residential AC (Including Heat Pumps) Washing Machines Fluorescent Ballasts Electric Water Heaters

McNeil, Michael A.

2012-01-01T23:59:59.000Z

109

Magnetic fluorescent lamp  

DOE Patents [OSTI]

The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly is enhanced by providing means for establishing a magnetic field with lines of force along the path of electron flow through the bulb of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

Berman, S.M.; Richardson R.W.

1983-12-29T23:59:59.000Z

110

Fluorescent temperature sensor  

DOE Patents [OSTI]

The present invention is a fluorescent temperature sensor or optical thermometer. The sensor includes a solution of 1,3-bis(1-pyrenyl)propane within a 1-butyl-1-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ionic liquid solvent. The 1,3-bis(1-pyrenyl)propane remains unassociated when in the ground state while in solution. When subjected to UV light, an excited state is produced that exists in equilibrium with an excimer. The position of the equilibrium between the two excited states is temperature dependent.

Baker, Gary A [Los Alamos, NM; Baker, Sheila N [Los Alamos, NM; McCleskey, T Mark [Los Alamos, NM

2009-03-03T23:59:59.000Z

111

Fluorescence analyzer for lignin  

SciTech Connect (OSTI)

A method and apparatus for measuring lignin concentration in a sample of wood pulp or black liquor comprises a light emitting arrangement for emitting an excitation light through optical fiber bundles into a probe which has an undiluted sensing end facing the sample. The excitation light causes the lignin concentration to produce fluorescent emission light which is then conveyed through the probe to analyzing equipment which measures the intensity of the emission light. Measures a This invention was made with Government support under Contract Number DOE: DE-FC05-90CE40905 awarded by the Department of Energy (DOE). The Government has certain rights in this invention.

Berthold, John W. (Salem, OH); Malito, Michael L. (Hubbard, OH); Jeffers, Larry (Alliance, OH)

1993-01-01T23:59:59.000Z

112

X-ray fluorescence mapping  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

biololgical cells, over the measurement of impurities in solar cells, to the rare earth content of geological materials. A somewhat 'typical' layout for a X-ray fluorescence...

113

Identification of Nucleotides with Identical Fluorescent Labels Based on Fluorescence  

E-Print Network [OSTI]

Identification of Nucleotides with Identical Fluorescent Labels Based on Fluorescence Polarization for discriminating among the four DNA nucleotides la- beled identically with tetramethylrhodamine is described and demonstrated. Labeled nucleotides were dissolved in buffered surfactant solutions. In room temperature 4.5 m

Myrick, Michael Lenn

114

Nuclear Resonance Fluorescence for Materials Assay  

E-Print Network [OSTI]

clandestine material with nuclear resonance fluorescence”.E. Norman, UC Berkeley Dept. of Nuclear Engineering, privatepp. 349. G. Warren et al. “Nuclear Resonance Fluorescence of

Quiter, Brian

2010-01-01T23:59:59.000Z

115

DOE/LX/07-0087&D1 Secondary Document DMSA C-333-41 Solid Waste...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

included welding rods, solder, a Nissen metal marker, fluorescent light starters, incandescent light bulbs and ends, fluorescent light bulb ends, miscellaneous lead pieces, and...

116

JY Tsao Evolution of Solid-State Lighting: Market Pull and Technology Push Xiamen 2005 Apr 13 Evolution of Solid-State Lighting  

E-Print Network [OSTI]

and Technology Push · Xiamen · 2005 Apr 13 0 20 40 60 80 100 0.1 1.0 10.0 100.0 Incandescent (12%) Fluorescent Fluorescent Standard Incandescent · So let's start with traditional lighting. · Here, I've plotted the 26 and Eugene Hong of Navigant Consulting. The lamps fall into three overall families: incandescent, in green

117

Solid-State lighting ReSeaRch & development at Sandia national laboRatoRieS  

E-Print Network [OSTI]

illumination via interface with microelectronics. MASSIVE ENERGY SAVINGS Incandescent and fluorescent lamps% efficient. Today's commercially available white LEDs are already five times as efficient as incandescent--or 10-15 times that of incandescent bulbs and 2-3 times that of fluorescents. BIG BOTTOM-LINE PAYOFF

118

Article #11, May 23, 2006 AJ's Technical Tips: Technologies for Lighting in Rural Africa  

E-Print Network [OSTI]

/a 30 lumens 0.1 Incandescent Bulb 15 W 225 lumens 15 Fluorescent Tube Lamp 10 W 500 lumens 50 White LED Lamp 1 W 30 lumens 30 The data in Table 1 show that incandescent bulbs and fluorescent tubes generate incandescent bulbs are about 150 times more efficient. In other words, electric lights are not only brighter

Jacobson, Arne

119

GREEN FLUORESCENT PROTEIN The green revolution  

E-Print Network [OSTI]

GREEN FLUORESCENT PROTEIN The green revolution Green fluorescent protein allows gene expression a fluorescent product when expressed. Just such a molecule, green fluorescent protein (GFP), has recently green light when disturbed (often seen when riding in a boat at night). In Aequorea, the green

Stearns, Tim

120

Nuclear Resonance Fluorescence for Nuclear Materials Assay  

E-Print Network [OSTI]

Potential of Nuclear Resonance Fluorescence . . . . . . . .2.9.1 Nuclear ThomsonSections . . . . . . . . . . . . . . . Nuclear Resonance

Quiter, Brian Joseph

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

September 2007 21 commonplace," predicted Shinichiro  

E-Print Network [OSTI]

enough and their lifetime is longer than those of conventional incandescent lamps and fluorescent lights." Also, he noted, LEDs' power efficiency is greater than that of incandescent lamps and about same

Lu, Chenyang

122

Funding Sustainable Initiatives: Should Williams Implement a Revolving Loan Fund?  

E-Print Network [OSTI]

to replace its incandescent light bulbs with more efficient compact fluorescent (CFL) light bulbs. These light bulbs use 2/3 less energy than #12;Terra 4 standard incandescent bulbs, but they are more

Aalberts, Daniel P.

123

Geaux Green: GREEN GUIDE  

E-Print Network [OSTI]

account. Make a switch Replace incandescent light bulbs with energy-efficient compact fluorescent lights. Remember: You should always turn your lights off regardless if they are incandescent bulbs or CFLs. Take

Harms, Kyle E.

124

Radioactivity-Synchronized Fluorescence Enhancement Using a Radionuclide Fluorescence-Quenched Dye  

E-Print Network [OSTI]

Radioactivity-Synchronized Fluorescence Enhancement Using a Radionuclide Fluorescence-Quenched Dye that demonstrates the feasibility of altering the fluorescence properties of an organic dye as a function effect on the dye fluorescence. Correlation of the radionuclide decay with the dye fluorescence

Larson-Prior, Linda

125

FIND A BIN, IT ALL GOES IN all types of paper  

E-Print Network [OSTI]

containers · ceramics, mirrors, windows, pyrex · incandescent light bulbs HAZARDOUS WASTE & CONFIDENTIAL: flatten next to containers, or place in marked dumpsters SPECIAL RECYCLING ITEMS: containers located

Thaxton, Christopher S.

126

Ceramic Mugs & Dishes Incandescent Light Bulbs  

E-Print Network [OSTI]

, MU East Rock Hall/19-B CELL PHONES - EYEGLASSES 654 Minnesota Street Room 208, copy room CVRI Helen. Zion Cancer Research Building N423 Parnassus Campus: eyeglasses "I" level, Optometry Store, MU West

Yamamoto, Keith

127

Energy-Saving Incandescents | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelinesProvedDecember 2005DepartmentDecember 2011District |Department

128

Energy-Saving Incandescents | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: TopEnergyIDIQBusinessinSupporting JobsClean EnergyAcross U.S. Industry

129

The National Energy Policy Act and lamp replacement options  

SciTech Connect (OSTI)

The National Policy Act of 1992 involves the creation of energy efficiency standards for a wide range of products including fluorescent and incandescent lamps. Minimum efficacy (lumens per watt) and color rendering index (CRI) standards are mandated for the popular fluorescent lamps: four-foot medium bi-pin, two-foot U-bent, eight-foot slimline and eight-foot high output. Minimum efficacies are mandated for specific incandescent R and PAR reflector lamps. These standards will affect selected colors and designs of fluorescent lamps, the most significant being the standard lamps in the cool white and warm white colors. The incandescent reflector lamps will include the R-30, R-40, PAR-38 lamps above 40 watts, excluding the halogen types. These efficiency and color rendering standards will require end-users and specifiers to select replacement fluorescent lamps from a range of performance characteristics (lumen output, efficacy, CRI and price). The choice of replacement for the R and PAR incandescent lamps will include the halogen designs and compact fluorescent designs. In this paper, replacement options will be analyzed and discussed and the effect of these options on the performance of the lighting system will be explored in detail.

Ryerson, C.

1995-06-01T23:59:59.000Z

130

Fluorescent Lighting | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power.pdf Flash2006-14.pdfattachment.pdf6.pdf5.pdfFluorescent Lighting Fluorescent Lighting

131

Covered Product Category: Fluorescent Ballasts  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including fluorescent ballasts, which are a FEMP-designated product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

132

Covered Product Category: Fluorescent Luminaires  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including fluorescent luminaires. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

133

Capacitive sensing with a fluorescent lamp  

E-Print Network [OSTI]

This work presents a modified fluorescent lamp that can be used as a capacitive sensing system. The lamp sensor measures changes in the electric fields emitted from the fluorescent bulbs in order to deduce the presence and ...

Cooley, John Jacob

2007-01-01T23:59:59.000Z

134

LED-Induced Fluorescence System for Tea Classification and Quality Assessment  

E-Print Network [OSTI]

A fluorescence system is developed by using several light emitting diodes (LEDs) with different wavelengths as excitation light sources. The fluorescence detection head consists of multi LED light sources and a multimode fiber for fluorescence collection, where the LEDs and the corresponding filters can be easily chosen to get appropriate excitation wavelengths for different applications. By analyzing fluorescence spectra with the principal component analysis method, the system is utilized in the classification of four types of green tea beverages and two types of black tea beverages. Qualities of the Xihu Longjing tea leaves of different grades, as well as the corresponding liquid tea samples, are studied to further investigate the ability and application of the system in the evaluation of classification/quality of tea and other foods.

Dong, Yongjiang; Mei, Liang; Feng, Chao; Yan, Chunsheng; He, Sailing

2013-01-01T23:59:59.000Z

135

Supplementary Material for: Application of Synchrotron Radiation for Measurement of Iron Red-ox  

E-Print Network [OSTI]

@engr.wisc.edu #12;Incandescent Light Bulb Spectrum Figure 1 Visible Light Fluorescent Light Bulb Spectrum #12;Figure 2 Visible Light Incandescent Light Bulb Spectrum #12;Figure 3 Unmodified XANES Spectrum February 14 of the incandescent lights used for aging the atmospheric aerosols. The units are in m / S / m2 / nm. Figure 3

Meskhidze, Nicholas

136

How Many CASTLE Bulbs Would You Need To Match the Brightness of the Sun?  

E-Print Network [OSTI]

;Suppose that you have two household incandescent bulbs: one is labeled "60W," the other "100W." If you try incandescent bulb and a 9W fluorescent bulb. Which one makes your room brighter? It's not what you might expect... in fact, they look about the same! The incandescent bulb emits a broad spectrum of visible and infrared

Collar, Juan I.

137

PipelineJuly 2012 Volume 4, Issue 4 (From President Kaler's June 14 e-mail)  

E-Print Network [OSTI]

the LightEnergy Management seeks incandescent and T12 lamps Energy Management Senior Engineer Alicia inefficient light sources. Although the vast majority of the campus's number one offenders -- incandescent fluorescent lamps and classic incandescent A-lamps. T12's can be identified by their "fat" appearance (1

Webb, Peter

138

EK101 Engineering Light Project: Evaluate Residential Lighting  

E-Print Network [OSTI]

for residential lighting (LED, Compact Fluorescent, Incandescent). Develop a plan of experiments to be conducted, CF, and Incandescent bulbs for the past ten years. (try the wayback time machine if other sources fail). Discuss the key challenges associated with a transition from incandescent lighting

Bifano, Thomas

139

Phys. Med. Biol. 43 (1998) 24072412. Printed in the UK PII: S0031-9155(98)90934-4 Effects of read-out light sources and ambient light on  

E-Print Network [OSTI]

laser, light emitting diode (LED) and incandescent read-out light sources produce an equivalent dose, fluorescent light and incandescent ambient light produce an equivalent dose coloration of 30 cGy h-1, 18 cGy h the optical density of Gafchromic films include, helium neon lasers, ultrabright diodes, incandescent

Yu, K.N.

140

Chromosome characterization using single fluorescent dye  

DOE Patents [OSTI]

Chromosomes are characterized by fluorescent emissions from a single fluorescent dye that is excited over two different wavelengths. A mixture containing chromosomes is stained with a single dye selected from the group consisting of TOTO and YOYO and the stained chromosomes are placed in a flow cytometer. The fluorescent dye is excited sequentially by a first light having a wavelength in the ultraviolet range to excite the TOTO or YOYO to fluoresce at a first intensity and by a second light having a wavelength effective to excite the TOTO or YOYO dye to fluoresce at a second intensity. Specific chromosomes may be identified and sorted by intensity relationships between the first and second fluorescence emissions.

Crissman, Harry A. (Los Alamos, NM); Hirons, Gregory T. (Irvine, CA)

1995-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Saccharide sensing molecules having enhanced fluorescent properties  

DOE Patents [OSTI]

The present invention provides formulae for fluorescent compounds that have a number of properties which make them uniquely suited for use in sensors of analytes such as saccharides. The advantageous fluorescent properties include favorable excitation wavelengths, emission wavelengths, fluorescence lifetimes, and photostability. Additional advantageous properties include enhanced aqueous solubility, as well as temperature and pH sensitivity. The compound comprises an aryl or a substituted phenyl botonic acid that acts as a substrate recognition component, a fluorescence switch component, and a fluorophore. Fluorescent compounds are described that are excited at wavelengths greater than 400 nm and emit at wavelengths greater than 450 nm, which is advantageous for optical transmission through skin. The fluorophore is typically selected from transition metal-ligand complexes and thiazine, oxazine, oxazone, or oxazine-one as well as anthracene compounds. The fluorescent compound can be immobilized in a glucose permeable biocompatible polymer matrix that is implantable below the skin.

Satcher Jr., Joe H.; Lane, Stephen M.; Darrow, Christopher B.; Cary, Douglas R.; Tran, Joe Anh

2004-01-06T23:59:59.000Z

142

Scanning fluorescent microthermal imaging apparatus and method  

DOE Patents [OSTI]

A scanning fluorescent microthermal imaging (FMI) apparatus and method is disclosed, useful for integrated circuit (IC) failure analysis, that uses a scanned and focused beam from a laser to excite a thin fluorescent film disposed over the surface of the IC. By collecting fluorescent radiation from the film, and performing point-by-point data collection with a single-point photodetector, a thermal map of the IC is formed to measure any localized heating associated with defects in the IC. 1 fig.

Barton, D.L.; Tangyunyong, P.

1998-01-06T23:59:59.000Z

143

Scanning fluorescent microthermal imaging apparatus and method  

DOE Patents [OSTI]

A scanning fluorescent microthermal imaging (FMI) apparatus and method is disclosed, useful for integrated circuit (IC) failure analysis, that uses a scanned and focused beam from a laser to excite a thin fluorescent film disposed over the surface of the IC. By collecting fluorescent radiation from the film, and performing point-by-point data collection with a single-point photodetector, a thermal map of the IC is formed to measure any localized heating associated with defects in the IC.

Barton, Daniel L. (Albuquerque, NM); Tangyunyong, Paiboon (Albuquerque, NM)

1998-01-01T23:59:59.000Z

144

Portable spotter for fluorescent contaminants on surfaces  

DOE Patents [OSTI]

A portable fluorescence-based spotter for polynuclear aromatic hydrocarbon contamination on personnel and work area surfaces under ambient lighting conditions is provided. This instrument employs beam modulation and phase sensitive detection for discriminating between fluorescence from organic materials from reflected background light and inorganic fluorescent material. The device uses excitation and emission filters to provide differentiation between classes of aromatic organic compounds. Certain inorganic fluorescent materials, including heavy metal compounds, may also be distinguished from the organic compounds, despite both having similar optical properties.

Schuresko, Daniel D. (Oak Ridge, TN)

1980-01-01T23:59:59.000Z

145

LED Replacements for Linear Fluorescent Lamps Webcast  

Broader source: Energy.gov [DOE]

In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting...

146

Covered Product Category: Compact Fluorescent Lamps  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including compact fluorescent lamps (CFLs), which are an ENERGY STAR-qualified product category.

147

Quantitative microscopic spectral fluorescence measurement of crude oil, bitumen, kerogen, and coal  

SciTech Connect (OSTI)

Ten samples each of black shale (kerogen and bitumen fractions) from Lias epsilon, coal from Western Canada and nine crude oil and condensate samples from Alaska and northern Germany have been studied using quantitative microscopic spectral fluorescence. The parameters used are lambda/sub max/, red/green quotient (Q), and alteration of fluorescence emission intensity under UV excitation. Using the same parameters, the data show that kerogen and crude oil have opposite maturation trends. Autochthonous bitumens include both kerogen and crude oil characters. Immature, biodegraded, or normal crude oil of different maturity can be characterized using these parameters. Quantitative spectral fluorescence microscopy yields more accurate maturation parameters for the Type I and II kerogens than vitrinite reflectance because the fluorescence of liptinites are used (i.e., the main oil-generating macerals). This method may become the most suitable inexpensive scanning technique for the characterization of crude oil, condensate, and autochthonous/allochthonous source rock bitumens.

Mukhopadhyay, P.K.; Rullkoetter, J.

1986-05-01T23:59:59.000Z

148

Guide to Red Fluorescent Proteins and Biosensors for Flow Cytometry  

E-Print Network [OSTI]

CHAPTER 17 Guide to Red Fluorescent Proteins and Biosensors for Flow Cytometry Kiryl D. PiatkevichH Stability of Fluorescence F. Optimization of Nucleotide and Amino Acid Sequences III. Modern Advanced Red-Shifted FPs A. Orange Fluorescent Proteins B. Red Fluorescent Proteins C. Far-Red Fluorescent Proteins IV

Verkhusha, Vladislav V.

149

2014-12-30 Issuance: Energy Conservation Standard for General...  

Energy Savers [EERE]

2014-12-30 Issuance: Energy Conservation Standard for General Service Fluorescent Lamps and Incandescent Reflector Lamps; Final Rule 2014-12-30 Issuance: Energy Conservation...

150

2014-04-11 Issuance: Energy Conservation Standards for General...  

Broader source: Energy.gov (indexed) [DOE]

Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps; Notice of Proposed Rulemaking 2014-04-11 Issuance: Energy Conservation...

151

Fabrication of color tunable organic light-emitting diodes by an alignment free mask patterning method  

E-Print Network [OSTI]

that of the incandescent bulb and comparable with that of the fluorescent tube. OLEDs are a true sur- face/area lighting

152

U.S. Energy Information Administration (EIA) - Sector  

Gasoline and Diesel Fuel Update (EIA)

replacement of incandescent bulbs with more efficient compact fluorescent lighting and light-emitting diode (LED) lamps. Among electric end-use services in the residential...

153

Semiconductor Science and Technology  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

controlled illumination via interface with microelectronics. MASSIVE ENERGY SAVINGS Incandescent and fluorescent lamps convert less than 20% of electrical energy into visible...

154

Educators: Are You Ready to Teach Energy Literacy? Join our August...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

pedal for power and experience the difference in physical effort necessary to power incandescent, compact fluorescent, and LED lighting. This lesson highlighted Energy Principle 4,...

155

--No Title--  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

alike can also reduce power demand, and thus carbon emissions, by replacing the incandescent bulbs in their homes with energy-saving compact fluorescent bulbs. That's a handy...

156

--No Title--  

Broader source: Energy.gov (indexed) [DOE]

out fixtures to accommodate compact fluorescent bulbs instead of relying on incandescent bulbs. Energy Efficiency and Conservation Block Grants Native Village of Stevens...

157

CX-003584: Categorical Exclusion Determination | Department of...  

Broader source: Energy.gov (indexed) [DOE]

community facilities and based on the results of the audits, change fixtures from incandescent to fluorescent lighting. In addition, the IRHA proposes to conduct mechanical...

158

Energy Efficiency and Conservation Block Grant Program  

Broader source: Energy.gov (indexed) [DOE]

retrofits throughout the Village. These lighting retrofits would involve upgrading incandescent light fixtures to those that will accommodate compact fluorescent bulbs. In...

159

DOE/LX/07-0242&D1 Secondary Document DMSA C-400-05 Solid Waste...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

fuses, three capacitors, three circuit boards, sixteen vacuum tubes, thirty-two incandescent light bulbs or fluorescent light bulbs, gallon of nitric acid, five aerosol...

160

CX-000133: Categorical Exclusion Determination | Department of...  

Broader source: Energy.gov (indexed) [DOE]

the funding permits. Residences for the retrofits will be selected based on need. Incandescent bulbs would be replaced with compact fluorescent bulbs. Power consumption would be...

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

--No Title--  

Broader source: Energy.gov (indexed) [DOE]

until funds are expended. Retrofits will consist of changing fixtures from incandescent to fluorescent lighting. Recent experience with lighting retrofits in the region...

162

CX-000139: Categorical Exclusion Determination | Department of...  

Broader source: Energy.gov (indexed) [DOE]

until funds are expended. Retrofits will consist of changing fixtures from incandescent to fluorescent lighting. Recent experience with lighting retrofits in the region...

163

EA-1664: Finding of No Significant Impact | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps The U.S. Department of Energy has determined that the adoption of energy...

164

CX-000136: Categorical Exclusion Determination | Department of...  

Broader source: Energy.gov (indexed) [DOE]

retrofits for bathrooms of 42 residences. These retrofits would involve upgrading incandescent light fixtures to those that will accommodate compact fluorescent bulbs. It is...

165

--No Title--  

Broader source: Energy.gov (indexed) [DOE]

retrofits for bathrooms of 42 residences. These retrofits would involve upgrading incandescent light fixtures to those that will accommodate compact fluorescent bulbs. It is...

166

Energy Efficiency and Conservation Block Grant Program  

Broader source: Energy.gov (indexed) [DOE]

community facilities and based on the results of the audits, change fixtures from incandescent to fluorescent lighting. In addition, the IRHA proposes to conduct mechanical...

167

CX-000137: Categorical Exclusion Determination | Department of...  

Broader source: Energy.gov (indexed) [DOE]

out fixtures to accommodate compact fluorescent bulbs instead of relying on incandescent bulbs. DOCUMENT(S) AVAILABLE FOR DOWNLOAD CX-000137.pdf More Documents &...

168

--No Title--  

Broader source: Energy.gov (indexed) [DOE]

the funding permits. Residences for the retrofits will be selected based on need. Incandescent bulbs would be replaced with compact fluorescent bulbs. Power consumption would be...

169

CX-003246: Categorical Exclusion Determination | Department of...  

Broader source: Energy.gov (indexed) [DOE]

retrofits throughout the Village. These lighting retrofits would involve upgrading incandescent light fixtures to those that will accommodate compact fluorescent bulbs. In...

170

Understanding Drooping Light Emitting Diodes CEEM | U.S. DOE...  

Office of Science (SC) Website

Impact Understanding "droop" may result in cheaper, more efficient LEDs; LEDs are more energy efficient, smaller, and longer-lived than incandescent lamps or fluorescent...

171

Buying an Appliance this Holiday Season? ENERGY STAR Products...  

Office of Environmental Management (EM)

Freezers Room air conditioners Televisions Clothes washers Dishwashers Battery chargers Water heaters Fluorescent lamp ballasts Incandescent reflector lamps If your appliance has...

172

A novel fluorescence detection method for organosilanes  

SciTech Connect (OSTI)

Quinones such as phenanthraquinone and anthraquinone react with organosilanes giving persistent, strongly fluorescent radicals. The reactions are photochemically initiated, rapid, and facile; detection of concentrations of silanes in the 10{sup {minus}7} M range are readily achieved. The staring materials do not fluorescence making the procedure simple, selective and specific.

Yang, H.X.; Craw, M.T.; Depew, M.C.; Wan, J.K.S. (Queen's Univ., Kingston, Ontario (Canada))

1989-02-01T23:59:59.000Z

173

Applications of Nuclear Resonance Fluorescence  

SciTech Connect (OSTI)

Nuclear Resonance Fluorescence (NRF) has the potential of addressing a wide variety of applications, which require isotopic and/or elemental information about a sample. We have investigated a variety of non-proliferation applications that may be addressed by NRF. From these applications, we have selected two, measuring uranium enrichment in UF6 cylinders and material verification in dismantlement, to investigate in more detail. Analytical models have been developed to evaluate these applications, and test measurements have been conducted to validate those models. We found that it is unlikely with current technology to address the requirements for UF6 cylinder enrichment measurements. In contrast, NRF is a very promising approach for material verification for dismantlement.

Warren, Glen A.; Detwiler, Rebecca S.; Peplowski, Patrick N.

2010-11-11T23:59:59.000Z

174

Excitation-emission spectra and fluorescence quantum yields for...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Excitation-emission spectra and fluorescence quantum yields for fresh and aged biogenic secondary organic aerosols. Excitation-emission spectra and fluorescence quantum yields for...

175

Hard X-ray Fluorescence Measurements of Heteroepitaxial Solid...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Hard X-ray Fluorescence Measurements of Heteroepitaxial Solid Oxide Fuel Cell Cathode Materials. Hard X-ray Fluorescence Measurements of Heteroepitaxial Solid Oxide Fuel Cell...

176

Hiding patterns with daylight fluorescent inks  

E-Print Network [OSTI]

We propose a method for hiding patterns within printed images by making use of classical and of two daylight fluorescent magenta and yellow inks. Under the D65 illuminant we establish in the CIELAB space the gamut of a classical cmyk printer and the gamut of the same printer using a combination of classical inks with daylight fluorescent inks. These gamuts show that a significant part of the classical ink gamut can be reproduced by combining classical inks with daylight fluorescent inks. By printing parts of images with a combination of classical and daylight fluorescent inks instead of using classical inks only, we can hide security patterns within printed images. Under normal daylight, we do not see any difference between the parts printed with classical inks only and the parts printed with daylight fluorescent inks and classical inks. By changing the illumination, e.g. by viewing the printed image under a tungsten lamp or under a UV lamp, the daylight fluorescent inks change their colors and reveal the security pattern formed by combinations of classical inks and of daylight fluorescent inks.

Romain Rossier; Roger D. Hersch; School Of Computer; Communication Sciences; Ecole Polytechnique; Fédérale Lausanne

177

Glucose sensing molecules having selected fluorescent properties  

DOE Patents [OSTI]

An analyte sensing fluorescent molecule that employs intramolecular electron transfer is designed to exhibit selected fluorescent properties in the presence of analytes such as saccharides. The selected fluorescent properties include excitation wavelength, emission wavelength, fluorescence lifetime, quantum yield, photostability, solubility, and temperature or pH sensitivity. The compound comprises an aryl or a substituted phenyl boronic acid that acts as a substrate recognition component, a fluorescence switch component, and a fluorophore. The fluorophore and switch component are selected such that the value of the free energy for electron transfer is less than about 3.0 kcal mol.sup.-1. Fluorescent compounds are described that are excited at wavelengths greater than 400 nm and emit at wavelengths greater than 450 nm, which is advantageous for optical transmission through skin. The fluorophore is typically selected from transition metal-ligand complexes and thiazine, oxazine, oxazone, or oxazine-one as well as anthracene compounds. The fluorescent compound can be immobilized in a glucose permeable biocompatible polymer matrix that is implantable below the skin.

Satcher Jr., Joe H.; Lane, Stephen M.; Darrow, Christopher B.; Cary, Douglas R.; Tran, Joe Anh

2004-01-27T23:59:59.000Z

178

Effect of Combining Far-Red Light with Shorter Wave Light on the Excitation of Fluorescence  

E-Print Network [OSTI]

of Fluorescence in Chlorella Recent experiments on the rate of photosyn- thesis in far-red light alone that the quantum yield of Auo- rescence in Chlorella drops when excitation is achieved by light above 680 ml* (10- teen experiments of this type are summarized in Table I. Chlorella pyrenoidosa Strain 3 were used

Govindjee

179

Epi-Fluorescence Inverted Microscope (Zeiss,  

E-Print Network [OSTI]

Epi-Fluorescence Inverted Microscope (Zeiss, Observer Z1) April 2013 #12;Start Up cont. · Turn) #12;Using the Microscope cont. · On an inverted microscope samples on a glass slide are usually viewed

Subramanian, Venkat

180

Probing the denatured state ensemble with fluorescence  

E-Print Network [OSTI]

around the original tryptophan substitutions in RNase Sa. Regardless of the denaturant, ?max for the proteins and model compounds differed very little, 349.3 ± 1.2 nm. However, significant differences were observed in the fluorescence intensity at ?max...

Alston, Roy Willis

2004-09-30T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

ELIZABETH H. AMARAL and H. ARNOLD CARR Experimental Fishing for Squid  

E-Print Network [OSTI]

south- ern California became dependent upon lamps, principally the incandescent type, combined under I,OOO-watt incandescent lights!. However, the squid never Introduction July-A ugusl 1980 51 #12

182

COMBINED FLUORESCENT AND GOLD PROBES FOR MICROSCOPIC AND MORPHOLOGICAL INVESTIGATIONS.  

SciTech Connect (OSTI)

Nanogold{reg_sign}, a gold cluster with a core of gold atoms 1.4 nm in diameter, has proven to be a superior probe label for electron microscopy (EM), giving both higher labeling density and improved access to previously hindered or restricted antigens. It may be visualized by autometallography (AMG) for use in light microscopy (LM): silver-and gold-amplified Nanogold detection has proven to be one of the most sensitive methods available for the detection of low copy number targets such as viral DNA in cells and tissue specimens. AMG enhancement has also made Nanogold an effective detection label in blots and gels. The following protocols will be described: Labeling of nuclear components in cells. Protocol for in situ hybridization and detection with fluorescein-Nanogold--or Cy3{trademark}-Nanogold-labeled streptavidin. Nanogold is an inert molecule, and generally does not interact with biological molecules unless a specific chemical reactivity is introduced into the molecule. Conjugates are prepared using site-specific chemical conjugation through reactive chemical functionalities introduced during Nanogold preparation, which allows the gold label to be attached to a specific site on the conjugate biomolecule. For example, a maleimido-Nanogold derivative, which is specific for thiol binding, is frequently attached to the hinge region of an antibody at a unique thiol site generated by selective reduction of a hinge disulfide. This site is remote from the antigen combining region, and the Nanogold, therefore, does not compromise target binding. Nanogold may also be prepared with specific reactivity towards amines or other unique chemical groups. This mode of attachment enables the preparation of probes labeled with both Nanogold and fluorescent labels. Different chemical reactivities are used to attach the Nanogold and the fluorescent groups to different sites in the conjugate biomolecule, as shown in Figure 7.1. In this manner, the two labels are spaced sufficiently far apart that fluorescent resonance energy transfer does not quench the fluorescent signal, and the probes may be used to label specimens for fluorescent and EM observation in a single staining procedure. This reduces the complexity of the staining procedure, allowing less specimen perturbation, and also enables a higher degree of correlation between the fluorescence and EM localization of the target, thus increasing the usefulness of the complementary data sets. Since gold and fluorescent-labeled probes are often used at different concentrations under different conditions, optimum procedures for the use of fluorescent and gold probes may entail some degree of compromise between the most appropriate conditions for the two types of probes. However, the chemical stability of the Nanogold label means that it is generally stable to a wide range of use conditions, and the following protocols have been found to be effective for labeling specimens with combined fluorescein and Nanogold-labeled antibody Fab' probes and with combined Cy3 and Nanogold-labeled streptavidin.

POWELL,R.D.HAINFELD,J.F.

2002-04-17T23:59:59.000Z

183

Multiplexed fluorescence detector system for capillary electrophoresis  

DOE Patents [OSTI]

A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis. 14 figures.

Yeung, E.S.; Taylor, J.A.

1994-06-28T23:59:59.000Z

184

Multiplexed fluorescence detector system for capillary electrophoresis  

DOE Patents [OSTI]

A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis. 14 figs.

Yeung, E.S.; Taylor, J.A.

1996-03-12T23:59:59.000Z

185

Research Focus High-throughput screens for fluorescent dye discovery  

E-Print Network [OSTI]

Research Focus High-throughput screens for fluorescent dye discovery Vebjorn Ljosa and Anne E of a combinatorial library of fluorescent compounds discovered fluorescent dyes that were able to distinguish myoblasts from differentiated myotubes. New fluorescent dyes that respond to biologically relevant changes

Carpenter, Anne E.

186

Ultratrace analysis of transuranic actinides by laser-induced fluorescence  

DOE Patents [OSTI]

Ultratrace quantities of transuranic actinides are detected indirectly by their effect on the fluorescent emissions of a preselected fluorescent species. Transuranic actinides in a sample are coprecipitated with a host lattice material containing at least one preselected fluorescent species. The actinide either quenches or enhances the laser-induced fluorescence of the preselected fluorescent species. The degree of enhancement or quenching is quantitatively related to the concentration of actinide in the sample.

Miller, S.M.

1983-10-31T23:59:59.000Z

187

Real-time Fourier transform spectrometry for fluorescence imaging and flow cytometry  

SciTech Connect (OSTI)

We present a Fourier transform (FT) spectrometer that is suitable for real-time spectral analysis in fluorescence imaging and flow cytometry. The instrument consists of a novel type of interferometer that can be modulated at frequencies of up to 100 kHz and has a high light throughput; and a dedicated, parallel array processor for the real-time computation of spectral parameters. The data acquisition array processor can be programmed by a host computer to perform any desired linear transform on the interferogram and can thus separate contributions from multiple fluorescence microscopy. The integration of a flow cytometer and a spectral imaging fluorescence microscope is discussed, and the concepts of direct and reversed virtual sorting'' are introduced. 9 refs., 8 figs.

Buican, T.N.

1990-01-01T23:59:59.000Z

188

Supercontinuum Stimulated Emission Depletion Fluorescence Lifetime Imaging  

SciTech Connect (OSTI)

Supercontinuum (SC) stimulated emission depletion (STED) fluorescence lifetime imaging is demonstrated by using time-correlated single-photon counting (TCSPC) detection. The spatial resolution of the developed STED instrument was measured by imaging monodispersed 40-nm fluorescent beads and then determining their fwhm, and was 36 ± 9 and 40 ± 10 nm in the X and Y coordinates, respectively. The same beads measured by confocal microscopy were 450 ± 50 and 430 ± 30 nm, which is larger than the diffraction limit of light due to underfilling the microscope objective. Underfilling the objective and time gating the signal were necessary to achieve the stated STED spatial resolution. The same fluorescence lifetime (2.0 ± 0.1 ns) was measured for the fluorescent beads by using confocal or STED lifetime imaging. The instrument has been applied to study Alexa Fluor 594-phalloidin labeled F-actin-rich projections with dimensions smaller than the diffraction limit of light in cultured cells. Fluorescence lifetimes of the actin-rich projections range from 2.2 to 2.9 ns as measured by STED lifetime imaging.

Lesoine, Michael; Bose, Sayantan; Petrich, Jacob; Smith, Emily

2012-06-13T23:59:59.000Z

189

Fluorescence energy transfer enhancement in aluminum nanoapertures  

E-Print Network [OSTI]

Zero-mode waveguides (ZMWs) are confining light into attoliter volumes, enabling single molecule fluorescence experiments at physiological micromolar concentrations. Among the fluorescence spectroscopy techniques that can be enhanced by ZMWs, F\\"{o}rster resonance energy transfer (FRET) is one of the most widely used in life sciences. Combining zero-mode waveguides with FRET provides new opportunities to investigate biochemical structures or follow interaction dynamics at micromolar concentration with single molecule resolution. However, prior to any quantitative FRET analysis on biological samples, it is crucial to establish first the influence of the ZMW on the FRET process. Here, we quantify the FRET rates and efficiencies between individual donor-acceptor fluorophore pairs diffusing in aluminum zero-mode waveguides. Aluminum ZMWs are important structures thanks to their commercial availability and the large literature describing their use for single molecule fluorescence spectroscopy. We also compare the ...

de Torres, Juan; Moparthi, Satish Babu; Grigoriev, Victor; Wenger, Jérome

2015-01-01T23:59:59.000Z

190

System Architecture Directions for a Software-Defined Lighting Infrastructure  

E-Print Network [OSTI]

spectrum of an outdoor environment and a typical fluorescent tube-lit office space. Indoor spectrum to incandescent and fluorescent lights. Unfortunately, the remarkable march of semiconductor technology a renaissance. The staple of illumi- nation for one and a half centuries, the incandescent bulb, is being phased

Dutta, Prabal

191

Fluorescence relaxation dynamics of CdSe and CdSe/CdS core/shell quantum dots  

SciTech Connect (OSTI)

Time-resolved fluorescence spectra for colloidal CdSe and CdSe/CdS core/shell quantum dots have been investigated to know their electron relaxation dynamics at the maximum steady state fluorescence intensity. CdSe core and CdSe/CdS type I core-shell materials with different shell (CdS) thicknesses have been synthesized using mercaptoacetic acid as a capping agent. Steady state absorption and emission studies confirmed successful synthesis of CdSe and CdSe/CdS core-shell quantum dots. The fluorescence shows a tri-exponential decay with lifetimes 57.39, 7.82 and 0.96 ns for CdSe quantum dots. The lifetime of each recombination decreased with growth of CdS shell over the CdSe core, with maximum contribution to fluorescence by the fastest transition.

Kaur, Gurvir; Kaur, Harmandeep [Centre of Advanced Study in Physics, Department of Physics, Panjab University, Chandigarh-160014 (India); Tripathi, S. K., E-mail: surya@pu.ac.in [Centre of Advanced Study in Physics, Panjab University, Chandigarh- 160014 (India)

2014-04-24T23:59:59.000Z

192

Fluorescent labels and their use in separations  

DOE Patents [OSTI]

Compositions are provided comprising sets of fluorescent labels carrying pairs of donor and acceptor dye molecules, designed for efficient excitation of the donors at a single wavelength and emission from the acceptor in each of the pairs at different wavelengths. The different molecules having different donor-acceptor pairs can be modified to have substantially the same mobility under separation conditions, by varying the distance between the donor and acceptor in a given pair. Particularly, the fluorescent compositions find use as labels in sequencing nucleic acids.

Mathies, Richard A. (El Cerrito, CA); Glazer, Alexander (Orinda, CA); Ju, Jingyue (Berkeley, CA)

1997-01-01T23:59:59.000Z

193

Ultrabright fluorescent OLEDS using triplet sinks  

DOE Patents [OSTI]

A first device is provided. The first device further comprises an organic light emitting device. The organic light emitting device further comprises an anode, a cathode, and an emissive layer disposed between the anode and the cathode. The emissive layer further comprises an organic host compound, an organic emitting compound capable of fluorescent emission at room temperature, and an organic dopant compound. The triplet energy of the dopant compound is lower than the triplet energy of the host compound. The dopant compound does not strongly absorb the fluorescent emission of the emitting compound.

Zhang, Yifan; Forrest, Stephen R; Thompson, Mark

2013-06-04T23:59:59.000Z

194

CODED SPECTROSCOPY FOR ETHANOL DETECTION IN DIFFUSE, FLUORESCENT MEDIA  

E-Print Network [OSTI]

ABSTRACT CODED SPECTROSCOPY FOR ETHANOL DETECTION IN DIFFUSE, FLUORESCENT MEDIA by Scott Thomas Mc FOR ETHANOL DETECTION IN DIFFUSE, FLUORESCENT MEDIA by Scott Thomas McCain Department of Electrical

195

Text-Alternative Version: LED Replacements for Linear Fluorescent Lamps  

Broader source: Energy.gov [DOE]

Below is the text-alternative version of the "LED Replacements for Linear Fluorescent Lamps" webcast, held June 20, 2011.

196

Red fluorescent proteins: chromophore formation and cellular applications  

E-Print Network [OSTI]

Red fluorescent proteins: chromophore formation and cellular applications Atsushi Miyawaki1,2 , Daria M Shcherbakova3,4 and Vladislav V Verkhusha3,4 In the last decade, a number of red fluorescent proteins (RFPs) that emit orange, red, and far-red fluorescence have been isolated from anthozoans (corals

Verkhusha, Vladislav V.

197

LIGHT-INDUCED CHANGES IN THE FLUORESCENCE YIELD OF  

E-Print Network [OSTI]

OF PREILLUMINATION ON THE FLUORESCENCE TRANSIENT OF Chlorella pyrenoidosa JOHN C. MUNDAY, JR., and GOVINDJEE From Mexico 88330. ABSTRACT The fluorescence transient of Chlorella pyrenoidosa, excited by saturat- ing blue Chlorella pyrenoidosa the fluorescence transient exhibits a base level 0, a hump I at 50 msec. (at 1.5 X 104

Govindjee

198

LIGHT-INDUCED CHANGES IN THE FLUORESCENCE YIELD OF  

E-Print Network [OSTI]

LIGHT-INDUCED CHANGES IN THE FLUORESCENCE YIELD OF CHLOROPHYLL a IN VIVO II. CHLORELLA PYRENOIDOSA in Chlorella pyrenoidosa consists of a fast rise of the fluorescence yield from the level S (of the first wave photophosphorylation. INTRODUCTION The long-term fluorescence induction in Chlorella pyrenoidosa (second wave

Govindjee

199

Brief Communication 809 Photoactivation turns green fluorescent protein red  

E-Print Network [OSTI]

Brief Communication 809 Photoactivation turns green fluorescent protein red Michael B. Elowitz gene was first cloned, the Aequorea victoria green fluorescent protein (GFP) has become a powerful tool- wavelength (red) fluorescence has remained elusive. Here we describe a red-emitting, green

Elowitz, Michael

200

Abstract The typing of single nucleotide polymorphisms (SNPs) located throughout the mitochondrial genome  

E-Print Network [OSTI]

Abstract The typing of single nucleotide polymorphisms (SNPs) located throughout the mitochondrialGenome and subsequent primer extension. By enzymatically incorporating fluorescently labeled dideoxy- nucleotides (dd extension · Single nucleotide polymorphism · Multiplex PCR Introduction The increasing use of mitochondrial

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Preliminary evaluation of a fluorescence and radioisotope nuclear smuggling deterrence tag - final report (IL500E)  

SciTech Connect (OSTI)

This report summarizes the efforts completed in identifying candidate fluorescence compounds and radioisotopes for a developing tagging system. The tagging system is being developed as a deterrent to nuclear smuggling, by providing a means of: (1) tracing materials and pilferers to the facility of origin for any recovered special nuclear materials, (2) inventory control of long-term stored items containing special nuclear materials, and (3) tracking materials transferred between facilities. The system uses three types of materials to cover a range of applications intended to prevent the pilfering of special nuclear materials. One material, fluorescent compounds which are invisible without ultraviolet or near-infrared detection systems, is marked on controlled items with a tracking pattern that corresponds to a specified item in a specified location in the data control system. The tagging system uses an invisible, fluorescent dusting powder to mark equipment and personnel who inappropriately handle the tagged material. The tagging system also uses unique combinations of radionuclides to identify the facility of origin for any special nuclear material. This report also summarizes the efforts completed in identifying hardware that will be used for the tagging system. This hardware includes the devices for applying the tagging materials, the commercially available fluorescence detection systems, and gamma ray detection systems assembled from existing, commercially available technologies.

Hartenstein, S.D.; Aryaeinejad, R.; Delmastro, J.R. [and others

1997-04-01T23:59:59.000Z

202

Industrial Lighting Techniques and New Developments  

E-Print Network [OSTI]

families customarily categorized in three major groupings Incandescent, Fluorescent, and High Intensity Discharge sources. In the incandescent family, halogen capsule 'technology has led to many new general lighting sources the 90-Watt and 45-Watt... Par 38 lamps deliver the same light output in the beam as conventional 150- and 75-Watt incandescent Par sources while using 40\\ less wattage and maintaining lamp life. By reducing voltage to the filament in halogen ~apsule sources, lamps can...

Colotti, M. A.

203

Lighting Options for Homes.  

SciTech Connect (OSTI)

This report covers many aspects of various lighting options for homes. Types of light sources described include natural light, artificial light, incandescent lamps, fluorescent lamps, and high intensity discharge lamps. A light source selection guide gives the physical characteristics of these, design considerations, and common applications. Color, strategies for efficient lighting, and types of lighting are discussed. There is one section giving tips for various situations in specific rooms. Rooms and types of fixtures are shown on a matrix with watts saved by using the recommended type lighting for that room and room location. A major emphasis of this report is saving energy by utilizing the most suitable, recommended lighting option. (BN)

Baker, W.S.

1991-04-01T23:59:59.000Z

204

ECE 466: LED Lighting Systems -Incandescent lightings rise and  

E-Print Network [OSTI]

versus cost - Power Electronic Drives for CFL and LED light sources to achieve dimmable operation - Basic electric AC and DC circuits at Sophomore level or equivalents Absolutes Lighting System Requirements index as a metric of a light source - Power Electronic Energy sources driving light sources in a compact

Schumacher, Russ

205

Underwater Lighting by Submerged Lasers and Incandescent Sources  

E-Print Network [OSTI]

books. For eX3.I11ple, equation (5.49.1) on page 107 of Glastone and Edlund's, "Elements of Nuclear Reactor

Duntley, Seibert Q

1971-01-01T23:59:59.000Z

206

How Energy-Efficient Light Bulbs Compare with Traditional Incandescents |  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-SeriesFlickr FlickrGuidedCH2MLLC HistoryVeterans | UpdatesHowGetDoes a

207

Replacing Incandescent Lightbulbs and Ballasts | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassive Solar HomePromisingStories » Removing nuclear waste,

208

DOE Requires Manufacturer and Labeler to Cease Sale of Incandescent  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana. DOCUMENTSof Energy DOEDOEAVAILABLEDepartment ofHeld

209

Replacing Incandescent Lightbulbs and Ballasts | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |EnergyonSupport0.pdf5Post-Holiday HolidayProcessRateofofRenewable EnergyRenewable

210

Fluorescent Lamp Ballasts | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecordFederal7.pdfFlash_2010_-24.pdfOverview Flow Cells forFluorescent Lamp

211

Solid state laser media driven by remote nuclear powered fluorescence  

DOE Patents [OSTI]

An apparatus is provided for driving a solid state laser by a nuclear powered fluorescence source which is located remote from the fluorescence source. A nuclear reaction produced in a reaction chamber generates fluorescence or photons. The photons are collected from the chamber into a waveguide, such as a fiber optic waveguide. The waveguide transports the photons to the remote laser for exciting the laser.

Prelas, Mark A. (Columbia, MO)

1992-01-01T23:59:59.000Z

212

Optical Nanofibers for Manipulating and Probing Single-Atom Fluorescence  

E-Print Network [OSTI]

We demonstrate how optical nanofibers can be used to manipulate and probe single-atom fluorescence. We show that fluorescence photons from a very small number of atoms, average atom number of less than 0.1, around the nanofiber can readily be observed through single-mode optical fiber under resonant laser irradiation. We show also that optical nanofibers enable us to probe the van der Waals interaction between atoms and surface with high precision by observing the fluorescence excitation spectrum.

K. P. Nayak; P. N. Melentiev; M. Morinaga; Fam Le Kien; V. I. Balykin; K. Hakuta

2006-10-17T23:59:59.000Z

213

Optical Nanofibers for Manipulating and Probing Single-Atom Fluorescence  

E-Print Network [OSTI]

We demonstrate how optical nanofibers can be used to manipulate and probe single-atom fluorescence. We show that fluorescence photons from a very small number of atoms, average atom number of less than 0.1, around the nanofiber can readily be observed through single-mode optical fiber under resonant laser irradiation. We show also that optical nanofibers enable us to probe the van der Waals interaction between atoms and surface with high precision by observing the fluorescence excitation spectrum.

Nayak, K P; Morinaga, M; Le Kien, F; Balykin, V I; Hakuta, K; Kien, Fam Le

2006-01-01T23:59:59.000Z

214

Using fluorescence lifetime for discriminating detector afterpulsing in fluorescence-correlation spectroscopy  

E-Print Network [OSTI]

ACF , i.e., the second- order correlation function of the fluorescence intensity sig- nal. The physical meaning of the ACF is that it is propor- tional to the probability to detect, on average, a photon- nique, although the analysis does not explicitly identify single molecule detection events. On different

Enderlein, Jörg

215

Super-Resolution Fluorescence Nanoscopy Applied to Image Core...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

state of the photoswitching dyes do not absorb at wavelength of the fluorescence excitation. As a result, almost all the interfering fluorophores can be photobleached by the...

216

Time-resolved fluorescence decay measurements for flowing particles  

DOE Patents [OSTI]

Time-resolved fluorescence decay measurements for flowing particles. An apparatus and method for the measurement and analysis of fluorescence for individual cells and particles in flow are described, wherein the rapid measurement capabilities of flow cytometry and the robust measurement and analysis procedures of time-domain fluorescence lifetime spectroscopy are combined. A pulse-modulated cw laser is employed for excitation of the particles. The characteristics and the repetition rate of the excitation pulses can be readily adjusted to accommodate for fluorescence decays having a wide range of lifetimes.

Deka, Chiranjit (Miami, FL); Steinkamp, John A. (Los Alamos, NM)

1999-01-01T23:59:59.000Z

217

Time-resolved fluorescence decay measurements for flowing particles  

DOE Patents [OSTI]

Time-resolved fluorescence decay measurements are disclosed for flowing particles. An apparatus and method for the measurement and analysis of fluorescence for individual cells and particles in flow are described, wherein the rapid measurement capabilities of flow cytometry and the robust measurement and analysis procedures of time-domain fluorescence lifetime spectroscopy are combined. A pulse-modulated CW laser is employed for excitation of the particles. The characteristics and the repetition rate of the excitation pulses can be readily adjusted to accommodate for fluorescence decays having a wide range of lifetimes. 12 figs.

Deka, C.; Steinkamp, J.A.

1999-06-01T23:59:59.000Z

218

Fluorescent Multiblock ?-Conjugated Polymer Nanoparticles for In Vivo Tumor Targeting  

E-Print Network [OSTI]

Highly fluorescent multiblock conjugated polymer nanoparticles with folic acid surface ligands are highly effective for bioimaging and in vivo tumor targeting. The targeted nanoparticles were preferentially localized in ...

Ahmed, Eilaf

219

Fluorescent Pigments for High-Performance Cool Roofing and Facades...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

3 Berkeley Lab Heat Island Group physicist Paul Berdahl inserts precursor solution into a furnace. After boiling and then combustion, a fluorescent red pigment is formed. Image:...

220

aequorea green fluorescent: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

plants. Jim Haseloff Biology and Medicine Websites Summary: light, and an accessory green fluorescent protein (GFP), which accepts energy from aequorin and reImaging green...

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Modeling of highly loaded fluorescent lamps  

SciTech Connect (OSTI)

Numerical modeling of the positive column of fluorescent lamps under conditions of high current density are of current interest, particularly in view of recent developments in electrodeless lamps. Current models tend to overestimate radiation output, and consequently the maintenance electric field in these discharges. Under highly loaded conditions, mercury-rare gas fluorescent lamps exhibit strong mercury depletion on axis (cataphoresis), and an understanding of resonance radiation transport under these conditions is therefore vital to the development of models with a predictive capability. The authors have explored the effect of radial cataphoresis on resonance radiation trapping for situations in which the radiation transport is dominated by foreign gas broadening, Doppler broadening, or resonance collisional broadening of the spectral line. Several different production rates per unit volume of resonance (excited) atoms have also been studied. It is advantageous in many cases to parameterize the trapped decay rate in terms of the total number of ground state atoms in the positive column independent of their radial distribution. The results of this work have been included in a numerical model of the positive column and the predicted influence on discharge parameters will be presented for cases of interest to highly loaded lamps.

Lister, G.G.; Lawler, J.E.; Curry, J.J.

1999-07-01T23:59:59.000Z

222

High-performance CFL downlights: The best and the brightest  

SciTech Connect (OSTI)

Downlight fixtures -- often referred to as ``recessed cans`` -- are among the most common lighting fixtures in commercial and residential settings. As such, they represent one of the most promising targets for improving lighting energy efficiency. The authors estimate that downlight fixtures account for more than one-fifth of the 2.8 billion incandescent lighting sockets in the US, and represent about 8 percent of total direct lighting energy use. Over 30 million new fixtures of this type are sold each year in the US. With existing and foreseeable technology, nearly two-thirds of the incandescent downlights in the US are candidates for retrofit or replacement with compact fluorescent lamps (CFLs) or fixtures. The remaining one-third, however, are unlikely to ever be replaceable with CFL technology because of constraints on light output, lighting quality, size, and cost-effectiveness of CFL alternatives. High performance downlight systems using compact fluorescent lamps and incorporating advanced optical, thermal, and ballast designs use up to 75 percent less energy than conventional incandescent downlight fixtures. Many CFL downlight fixtures, however, perform poorly. In this report, the authors explore ways in which various elements of fixture design influence performance. They also describe exemplary elements of high-performance designs, and evaluate several emerging or experimental technologies that promise to further improve efficiency.

Sardinsky, R.; Hawthorne, S.; Newcomb, J.

1993-12-31T23:59:59.000Z

223

Max Tech and Beyond: Fluorescent Lamps  

SciTech Connect (OSTI)

Fluorescent lamps are the most widely used artificial light source today, responsible for approximately 70% of the lumens delivered to our living spaces globally. The technology was originally commercialized in the 1930's, and manufacturers have been steadily improving the efficacy of these lamps over the years through modifications to the phosphors, cathodes, fill-gas, operating frequency, tube diameter and other design attributes. The most efficient commercially available fluorescent lamp is the 25 Watt T5 lamp. This lamp operates at 114-116 lumens per watt while also providing good color rendering and more than 20,000 hours of operating life. Industry experts interviewed indicated that while this lamp is the most efficient in the market today, there is still a further 10 to 14% of potential improvements that may be introduced to the market over the next 2 to 5 years. These improvements include further developments in phosphors, fill-gas, cathode coatings and ultraviolet (UV) reflective glass coatings. The commercialization of these technology improvements will combine to bring about efficacy improvements that will push the technology up to a maximum 125 to 130 lumens per watt. One critical issue raised by researchers that may present a barrier to the realization of these improvements is the fact that technology investment in fluorescent lamps is being reduced in order to prioritize research into light emitting diodes (LEDs) and ceramic metal halide high intensity discharge (HID) lamps. Thus, it is uncertain whether these potential efficacy improvements will be developed, patented and commercialized. The emphasis for premium efficacy will continue to focus on T5 lamps, which are expected to continue to be marketed along with the T8 lamp. Industry experts highlighted the fact that an advantage of the T5 lamp is the fact that it is 40% smaller and yet provides an equivalent lumen output to that of a T8 or T12 lamp. Due to its smaller form factor, the T5 lamp contains less material (i.e., glass, fill gas and phosphor), and has a higher luminance, enabling fixtures to take advantage of the smaller lamp size to improve the optics and provide more efficient overall system illuminance. In addition to offering the market a high-quality efficacious light source, another strong value proposition of fluorescent lighting is its long operating life. In today's market, one manufacturer is offering fluorescent lamps that have a rated life of 79,000 hours - which represents 18 years of service at 12 hours per day, 365 days per year. These lamps, operated using a long-life ballast specified by the manufacturer, take advantage of improvements in cathode coatings, fill gas chemistry and pressure to extend service life by a factor of four over conventional fluorescent lamps. It should be noted that this service life is also longer (approximately twice as long) as today's high-quality LED products. The fluorescent market is currently focused on the T5 and T8 lamp diameters, and it is not expected that other diameters would be introduced. Although T8 is a more optimal diameter from an efficacy perspective, the premium efficiency and optimization effort has been focused on T5 lamps because they are 40% smaller than T8, and are designed to operate at a higher temperature using high-frequency electronic ballasts. The T5 lamp offers savings in terms of materials, packaging and shipping, as well as smaller fixtures with improved optical performance. Manufacturers are actively researching improvements in four critical areas that are expected to yield additional efficacy improvements of approximately 10 to 14 percent over the next five years, ultimately achieving approximately 130 lumens per watt by 2015. The active areas of research where these improvements are anticipated include: (1) Improved phosphors which continue to be developed and patented, enabling higher efficacies as well as better color rendering and lumen maintenance; (2) Enhanced fill gas - adjusting proportions of argon, krypton, neon and xenon to optimize performance, while also m

Scholand, Michael

2012-04-01T23:59:59.000Z

224

Improved ``Optical Highlighter'' Probes Derived from Discosoma Red Fluorescent Protein  

E-Print Network [OSTI]

, Minneapolis, Minnesota ABSTRACT The tetrameric red fluorescent protein, DsRed, undergoes a rapid red to green-emitting species of DsRed and an enhancement of emission from the ``immature'' green species, likely caused by dequenching of fluorescence resonance energy transfer occurring within the protein tetramer. Here, we have

Marchant, Jonathan

225

A monomeric red fluorescent protein Robert E. Campbell*, Oded Tour*  

E-Print Network [OSTI]

A monomeric red fluorescent protein Robert E. Campbell*, Oded Tour* , Amy E. Palmer*, Paul A, and the obligate tetramerization of the red fluorescent protein from Discosoma (DsRed). Although the weak, the obligate tet- ramerization of DsRed has greatly hindered its use as a genetically encoded fusion tag. We

Tsien, Roger Y.

226

Gregorio Weber International Prize in Biological Fluorescence 2008  

E-Print Network [OSTI]

Gregorio Weber International Prize in Biological Fluorescence 2008 The Gregorio Weber International Prize in Biological Fluorescence (Weber Prize) is awarded for research related to a doctoral (or finalists. Weber Prizes were awarded in 2002 and 2005. The third Weber Prize will be awarded in 2008

Weber, David J.

227

Fluorescent Sensors for Zn2+ Based on a Fluorescein Platform  

E-Print Network [OSTI]

Fluorescent Sensors for Zn2+ Based on a Fluorescein Platform: Synthesis, Properties fluorescent sensors for Zn2+ that utilize fluorescein as a reporting group, Zinpyr-1 and Zinpyr-2, have been. Both Zinpyr sensors have excitation and emission wavelengths in the visible range (500 nm

Tsien, Roger Y.

228

Development and Application of Fluorescent SDF-1 Derivatives Ryo Masuda,  

E-Print Network [OSTI]

#12;1 Development and Application of Fluorescent SDF-1 Derivatives Ryo Masuda, Shinya Oishi of Medicine, 2-1 Seiryocho, Aoba-ku, Sendai 980-8575, Japan. #12;2 Abstract Background: SDF-1/CXCR4 signaling, structure-activity relationship analyses of fluorescent SDF-1 derivatives were carried out. Results: Several

Takada, Shoji

229

Multicontrast photoacoustic in vivo imaging using near-infrared fluorescent  

E-Print Network [OSTI]

Multicontrast photoacoustic in vivo imaging using near-infrared fluorescent proteins Arie Krumholz1 the application of two spectrally distinct near-infrared fluorescent proteins, iRFP670 and iRFP720, engineered-tissue PAT, probes absorbing in the near-infrared (NIR) spectral range are desirable. In the NIR optical

Verkhusha, Vladislav V.

230

Full-wavelet approach for fluorescence diffuse optical tomography  

E-Print Network [OSTI]

Full-wavelet approach for fluorescence diffuse optical tomography with structured illumination Leonardo da Vinci 32, I-20133 Milan, Italy 3 Centre for Medical Image Computing, University College London); published October 28, 2010 We present a fast reconstruction method for fluorescence optical tomography

Boyer, Edmond

231

Application of Quantitative Fluorescence and Absorption-Edge  

E-Print Network [OSTI]

Application of Quantitative Fluorescence and Absorption-Edge Computed Microtomography to Image, Chicago, Illinois 60637 This paper shows that synchrotron-based fluorescence and absorption-edge computed, which had a well-correlated metal coating. Absorption-edge CMT showed the three-dimensional distribution

Sparks, Donald L.

232

Fluorescence in nonlocal dissipative periodic structures  

E-Print Network [OSTI]

We present an approach for the description of fluorescence from optically active material embedded in layered periodic structures. Based on an exact electromagnetic Green's tensor analysis, we determine the radiative properties of emitters such as the local photonic density of states, Lamb shifts, line widths etc. for a finite or infinite sequence of thin alternating plasmonic and dielectric layers. In the effective medium limit, these systems may exhibit hyperbolic dispersion relations so that the large wave-vector characteristics of all constituents and processes become relevant. These include the finite thickness of the layers, the nonlocal properties of the constituent metals, and local-field corrections associated with an emitter's dielectric environment. In particular, we show that the corresponding effects are non-additive and lead to considerable modifications of an emitter's luminescence properties.

Francesco Intravaia; Kurt Busch

2015-02-24T23:59:59.000Z

233

SIMULTANEOUS MEASUREMENT OF CIRCULAR DICHROISM AND FLUORESCENCE POLARIZATION ANISOTROPY.  

SciTech Connect (OSTI)

Circular dichroism and fluorescence polarization anisotropy are important tools for characterizing biomolecular systems. Both are used extensively in kinetic experiments involving stopped- or continuous flow systems as well as titrations and steady-state spectroscopy. This paper presents the theory for determining circular dichroism and fluorescence polarization anisotropy simultaneously, thus insuring the two parameters are recorded under exactly the same conditions and at exactly the same time in kinetic experiments. The approach to measuring circular dichroism is that used in almost all conventional dichrographs. Two arrangements for measuring fluorescence polarization anisotropy are described. One uses a single fluorescence detector and signal processing with a lock-in amplifier that is similar to the measurement of circular dichroism. The second approach uses classic ''T'' format detection optics, and thus can be used with conventional photon-counting detection electronics. Simple extensions permit the simultaneous measurement of the absorption and excitation intensity corrected fluorescence intensity.

SUTHERLAND,J.C.

2002-01-19T23:59:59.000Z

234

SIM - Structured Illumination Super Resolution Fluorescence Microscope...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

induced obesity and concomitant development of insulin resistance (IR) and type 2 diabetes mellitus have been linked to... Identification of widespread adenosine nucleotide...

235

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and  

E-Print Network [OSTI]

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and HID (high-intensity discharge) lamps and all other mercury containing labeled for shipment to a recycling plant for mercury, glass and aluminum recovery. The beneficial re

Baker, Chris I.

236

Air Fluorescence Relevant for Cosmic-Ray Detection - Summary of the 5th Fluorescence Workshop, El Escorial 2007  

E-Print Network [OSTI]

High-energy cosmic rays with energies exceeding $10^{17}$ eV are frequently observed by measurements of the fluorescence light induced by air showers. A major contribution to the systematic uncertainties of the absolute energy scale of such experiments is the insufficient knowledge of the fluorescence light yield of electrons in air. The aim of the 5th Fluorescence Workshop was to bring together experimental and theoretical expertise to discuss the latest progress on the investigations of the fluorescence light yield. The results of the workshop will be reviewed as well as the present status of knowledge in this field. Emphasis is given to the fluorescence light yield important for air shower observations and its dependence on atmospheric parameters, like pressure, temperature, and humidity. The effects of the latest results on the light observed from air showers will be discussed.

Fernando Arqueros; Joerg R. Hoerandel; Bianca Keilhauer

2008-07-24T23:59:59.000Z

237

X-Ray Fluorescence (XRF) Analysis of Obsidian Artifacts from Shoofly Ruin, Central Arizona  

E-Print Network [OSTI]

X-RAY FLUORESCENCE (XRF) ANALYSIS OF OBSIDIAN ARTIFACTS FROM62:426-437. SOUTHWEST XRF PAPER Table 1. X-ray fluorescence

Shackley, M. Steven

1986-01-01T23:59:59.000Z

238

A Red Cy3-Based Biarsenical Fluorescent Probe Targeted to a Complement...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Red Cy3-Based Biarsenical Fluorescent Probe Targeted to a Complementary Binding Peptide. A Red Cy3-Based Biarsenical Fluorescent Probe Targeted to a Complementary Binding Peptide....

239

E-Print Network 3.0 - angle fluorescence interference Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

both the excitation and fluorescence detection bands of WIBS. Interference filters were avoided... A low-cost multi-channel aerosol fluorescence sensor for networked deployment...

240

E-Print Network 3.0 - albumin fluorescence study Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of tryptophan fluorescence decay in proteins using a subnanosecond 295 nm light-emitting diode Summary: . Fluorescence decay and anisotropy decay measurements of human serum...

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

E-Print Network 3.0 - activated delayed fluorescence Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

69 Rapid Communication Fluorescence Resonance Energy Transfer Analysis of Summary: Rapid Communication Fluorescence Resonance Energy Transfer Analysis of Cell Surface Receptor......

242

Crystallographic study of red fluorescent protein eqFP578 and its far-red variant Katushka reveals opposite pH-induced isomerization of chromophore  

SciTech Connect (OSTI)

The wild type red fluorescent protein eqFP578 (from sea anemone Entacmaea quadricolor, {lambda}{sub ex} = 552 nm, {lambda}{sub em} = 578 nm) and its bright far-red fluorescent variant Katushka ({lambda}{sub ex} = 588 nm, {lambda}{sub em} = 635 nm) are characterized by the pronounced pH dependence of their fluorescence. The crystal structures of eqFP578f (eqFP578 with two point mutations improving the protein folding) and Katushka have been determined at the resolution ranging from 1.15 to 1.85 {angstrom} at two pH values, corresponding to low and high level of fluorescence. The observed extinguishing of fluorescence upon reducing pH in eqFP578f and Katushka has been shown to be accompanied by the opposite trans-cis and cis-trans chromophore isomerization, respectively. Asn143, Ser158, His197 and Ser143, Leu174, and Arg197 have been shown to stabilize the respective trans and cis fluorescent states of the chromophores in eqFP578f and Katushka at higher pH. The cis state has been suggested as being primarily responsible for the observed far-red shift of the emission maximum of Katushka relative to that of eqFP578f.

Pletneva, Nadya V.; Pletnev, Vladimir Z.; Shemiakina, Irina I.; Chudakov, Dmitriy M.; Artemyev, Igor; Wlodawer, Alexander; Dauter, Zbigniew; Pletnev, Sergei (Russ. Acad. Sci.); (SAIC); (NCI)

2012-08-10T23:59:59.000Z

243

Fluorescent lamp unit with magnetic field generating means  

DOE Patents [OSTI]

A fluorescent lamp unit having a magnetic field generating means for improving the performance of the fluorescent lamp is disclosed. In a preferred embodiment the fluorescent lamp comprises four longitudinally extending leg portions disposed in substantially quadrangular columnar array and joined by three generally U-shaped portions disposed in different planes. In another embodiment of the invention the magnetic field generating means comprises a plurality of permanent magnets secured together to form a single columnar structure disposed within a centrally located region defined by the shape of lamp envelope. 4 figs.

Grossman, M.W.; George, W.A.

1989-08-08T23:59:59.000Z

244

Integrated ultrasonic particle positioning and low excitation light fluorescence imaging  

SciTech Connect (OSTI)

A compact hybrid system has been developed to position and detect fluorescent micro-particles by combining a Single Photon Avalanche Diode (SPAD) imager with an acoustic manipulator. The detector comprises a SPAD array, light-emitting diode (LED), lenses, and optical filters. The acoustic device is formed of multiple transducers surrounding an octagonal cavity. By stimulating pairs of transducers simultaneously, an acoustic landscape is created causing fluorescent micro-particles to agglomerate into lines. The fluorescent pattern is excited by a low power LED and detected by the SPAD imager. Our technique combines particle manipulation and visualization in a compact, low power, portable setup.

Bernassau, A. L.; Al-Rawhani, M.; Beeley, J.; Cumming, D. R. S. [School of Engineering, University of Glasgow, Glasgow, G12 8LT (United Kingdom)] [School of Engineering, University of Glasgow, Glasgow, G12 8LT (United Kingdom)

2013-12-09T23:59:59.000Z

245

Fluorescence Imaging for Nuclear Arms Control Verification  

E-Print Network [OSTI]

grade Pu typically contains more than 90% 239Pu.10 Additionally, the fissile material must be in metallic form. There are many different nuclear warhead designs, but there are three general warhead types: gun-type, implosion and thermonuclear. In a... into a supercritical configuration. A thermonuclear device combines an implosion device, known as the primary, with a secondary fusion device composed of uranium and lithium deuteride. Most modern weapons contain a thermonuclear warhead. Gun...

Feener, Jessica S

2014-08-14T23:59:59.000Z

246

THE HISTORY AND TECHNICAL EVOLUTION OF HIGH FREQUENCY FLUORESCENT LIGHTING  

E-Print Network [OSTI]

Dec. 1953. "Hi-Volt-Cycle Lighting ~ Launched i n a Hi-Wide2, F e b r u a r y , 19 53. "Lighting Your Plant with Highg h Frequency Fluorescent Lighting John H. Campbell December

Campbell, John H.

2011-01-01T23:59:59.000Z

247

REDUCING INCIDENTAL FLUORESCENCE IN LIVE CELL IMAGING A. Altinok 1  

E-Print Network [OSTI]

, the technique is based on staining bio molecules selectively with proteins carrying fluorescence dyes of known. For instance, length measurements in Fig.1 would lack accuracy since the ends of the objects are blurry within

California at Santa Barbara, University of

248

LIGHT-INDUCED CHANGES IN THE FLUORESCENCE YIELD OF  

E-Print Network [OSTI]

a in system II, the system which sensitizes the oxygen-evolving reaction (7-14). The factor controlling fluorescence intensity is the redox state of Q, the electron acceptor in the system It reaction center (9). Fig

Govindjee

249

Calibration of fluorescence resonance energy transfer in microscopy  

DOE Patents [OSTI]

Imaging hardware, software, calibrants, and methods are provided to visualize and quantitate the amount of Fluorescence Resonance Energy Transfer (FRET) occurring between donor and acceptor molecules in epifluorescence microscopy. The MicroFRET system compensates for overlap among donor, acceptor, and FRET spectra using well characterized fluorescent beads as standards in conjunction with radiometrically calibrated image processing techniques. The MicroFRET system also provides precisely machined epifluorescence cubes to maintain proper image registration as the sample is illuminated at the donor and acceptor excitation wavelengths. Algorithms are described that pseudocolor the image to display pixels exhibiting radiometrically-corrected fluorescence emission from the donor (blue), the acceptor (green) and FRET (red). The method is demonstrated on samples exhibiting FRET between genetically engineered derivatives of the Green Fluorescent Protein (GFP) bound to the surface of Ni chelating beads by histidine-tags.

Youvan, Dougalas C.; Silva, Christopher M.; Bylina, Edward J.; Coleman, William J.; Dilworth, Michael R.; Yang, Mary M.

2003-12-09T23:59:59.000Z

250

Exploring the mechanome with optical tweezers and single molecule fluorescence  

E-Print Network [OSTI]

The combination of optical tweezers and single molecule fluorescence into an instrument capable of making combined, coincident measurements adds an observable dimension that allows for the examination of the localized ...

Brau, Ricardo R. (Ricardo Rafael), 1979-

2008-01-01T23:59:59.000Z

251

Protein subcellular localization assays using split fluorescent proteins  

DOE Patents [OSTI]

The invention provides protein subcellular localization assays using split fluorescent protein systems. The assays are conducted in living cells, do not require fixation and washing steps inherent in existing immunostaining and related techniques, and permit rapid, non-invasive, direct visualization of protein localization in living cells. The split fluorescent protein systems used in the practice of the invention generally comprise two or more self-complementing fragments of a fluorescent protein, such as GFP, wherein one or more of the fragments correspond to one or more beta-strand microdomains and are used to "tag" proteins of interest, and a complementary "assay" fragment of the fluorescent protein. Either or both of the fragments may be functionalized with a subcellular targeting sequence enabling it to be expressed in or directed to a particular subcellular compartment (i.e., the nucleus).

Waldo, Geoffrey S. (Santa Fe, NM); Cabantous, Stephanie (Los Alamos, NM)

2009-09-08T23:59:59.000Z

252

Calibration of fluorescence resonance energy transfer in microscopy  

DOE Patents [OSTI]

Imaging hardware, software, calibrants, and methods are provided to visualize and quantitate the amount of Fluorescence Resonance Energy Transfer (FRET) occurring between donor and acceptor molecules in epifluorescence microscopy. The MicroFRET system compensates for overlap among donor, acceptor, and FRET spectra using well characterized fluorescent beads as standards in conjunction with radiometrically calibrated image processing techniques. The MicroFRET system also provides precisely machined epifluorescence cubes to maintain proper image registration as the sample is illuminated at the donor and acceptor excitation wavelengths. Algorithms are described that pseudocolor the image to display pixels exhibiting radiometrically-corrected fluorescence emission from the donor (blue), the acceptor (green) and FRET (red). The method is demonstrated on samples exhibiting FRET between genetically engineered derivatives of the Green Fluorescent Protein (GFP) bound to the surface of Ni chelating beads by histidine-tags.

Youvan, Douglas C. (San Jose, CA); Silva, Christopher M. (Sunnyvale, CA); Bylina, Edward J. (San Jose, CA); Coleman, William J. (Moutain View, CA); Dilworth, Michael R. (Santa Cruz, CA); Yang, Mary M. (San Jose, CA)

2002-09-24T23:59:59.000Z

253

Technical description of candidate fluorescence compounds and radioisotopes for a nuclear smuggling deterrence tag (IL500E)  

SciTech Connect (OSTI)

This report summarizes the efforts completed in identifying candidate fluorescence compounds and radioisotopes for a developing tagging system. The tagging system is being developed as a deterrent to nuclear smuggling, by providing a means of: (1) tracing materials and pilferers to the facility of origin for any recovered special nuclear materials; (2) inventory control of long-term stored items containing special nuclear materials; and (3) tracking materials transferred between facilities. The tagging system uses four types of tagging materials to cover a range of applications intended to prevent the pilfering of special nuclear materials. One material, fluorescent compounds which are invisible without ultraviolet or near-infrared detection systems, is marked on controlled items with a tracking pattern that corresponds to a specified item in a specified location in the data control system. The tagging system uses an invisible, fluorescent dusting powder to mark equipment and personnel who inappropriately handle the tagged material. The tagging system also uses unique combinations of radionuclides to identify the facility of origin for any special nuclear material. Currently, 18 long-lived radioisotopes, 38 short-live radioisotopes and 10 fluorescent compounds have been selected as candidate materials for the tagging system.

Hartenstein, S.D.; Aryaeinejad, R.

1996-03-01T23:59:59.000Z

254

Rapid identification of bacteria using an umbelliferone fluorescent assay  

E-Print Network [OSTI]

RAPID IDENTIFICATION OF BACTERIA USING AN UMBELLIFERONE FLUORESCENT ASSAY A Thesis by RICHARD THOMAS CHAMBLIN, JR, Submitted to the Graduate College of' Texas A&M University in partial fulfillment of the requirement for the degree of MASTER... OF SCIENCE August 1983 Major Subject: Veterinary Microbiology RAPID IDENTIFICATION OF BACTERIA USING AN UMBELLIFERONE FLUORESCENT ASSAY A Thesis by RICHARD THOMAS CHAMBLIN, JR ~ Approved as to style and content by ( -Chairman of Committee) John M...

Chamblin, Richard Thomas

1983-01-01T23:59:59.000Z

255

Development of laser excited atomic fluorescence and ionization methods  

SciTech Connect (OSTI)

Progress report: May 1, 1988 to December 31, 1991. The research supported by DE-FG05-88ER13881 during the past (nearly) 3 years can be divided into the following four categories: (1) theoretical considerations of the ultimate detection powers of laser fluorescence and laser ionization methods; (2) experimental evaluation of laser excited atomic fluorescence; (3) fundamental studies of atomic and molecular parameters in flames and plasmas; (4) other studies.

Winefordner, J.D.

1991-01-01T23:59:59.000Z

256

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

E-Print Network [OSTI]

standard for linear fluorescent lamps Length (mm) Minimum efficacy (lm/W) Efficacy for energy conservation

Lin, Jiang

2002-01-01T23:59:59.000Z

257

Application of fluorescence microscopy to coal-derived resid characterization  

SciTech Connect (OSTI)

This study evaluates the usefulness of a fluorescence microscopy methodology to analyze coal-derived resids and interpret the data in the light of liquefaction processing conditions, process response, the inferred resid reactivity, and in relation to results of other analytical data. The fluorescence technique utilized has been widely applied to coal and kerogen characterization, albeit with some modifications, but is novel in its application to the characterization of coal liquids. Fluorescence is the emission of light energy which occurs when electrons, having been excited to a higher energy orbital, return to their lower energy ground state. The majority of organic molecules that fluoresce are those with conjugated double bonds (chromophores), such as aromatics, characterized by pi-electrons less strongly bound within the molecule than sigma electrons, that can be excited to anti-bonding pi-orbitals. Increasing the extent of pi-bond conjugation (i.e. larger molecular size) generally imparts a shift in absorption and emission spectra to longer wavelengths. Resid fluorescence largely depends on the concentration and degree of conjugation of aromatic chromophores in the high molecular weight liquids, possibly with ancillary effects from oxygen functionalities. In this context, fluorescence analysis of liquefaction resids can potentially evaluate process performance, since direct liquefaction processes endeavor to break down the macromolecular structure of coal, and reduce the molecular weight of polycondensed aromatics through hydrogenation, the opening of ring structures, and heteroatom removal.

Rathbone, R.F.; Hower, J.C.; Derbyshire, F.J.

1991-01-01T23:59:59.000Z

258

Application of fluorescence microscopy to coal-derived resid characterization  

SciTech Connect (OSTI)

This study evaluates the usefulness of a fluorescence microscopy methodology to analyze coal-derived resids and interpret the data in the light of liquefaction processing conditions, process response, the inferred resid reactivity, and in relation to results of other analytical data. The fluorescence technique utilized has been widely applied to coal and kerogen characterization, albeit with some modifications, but is novel in its application to the characterization of coal liquids. Fluorescence is the emission of light energy which occurs when electrons, having been excited to a higher energy orbital, return to their lower energy ground state. The majority of organic molecules that fluoresce are those with conjugated double bonds (chromophores), such as aromatics, characterized by pi-electrons less strongly bound within the molecule than sigma electrons, that can be excited to anti-bonding pi-orbitals. Increasing the extent of pi-bond conjugation (i.e. larger molecular size) generally imparts a shift in absorption and emission spectra to longer wavelengths. Resid fluorescence largely depends on the concentration and degree of conjugation of aromatic chromophores in the high molecular weight liquids, possibly with ancillary effects from oxygen functionalities. In this context, fluorescence analysis of liquefaction resids can potentially evaluate process performance, since direct liquefaction processes endeavor to break down the macromolecular structure of coal, and reduce the molecular weight of polycondensed aromatics through hydrogenation, the opening of ring structures, and heteroatom removal.

Rathbone, R.F.; Hower, J.C.; Derbyshire, F.J.

1991-12-31T23:59:59.000Z

259

Development of rapid microbial methods for lysine quantification in feed ingredients based on green fluorescent protein fluorescence  

E-Print Network [OSTI]

fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY Approved by: Chair of Committee, Steven C. Ricke Committee Members, Deborah Siegele Jean Gould Dorothy Shippen Chair of Molecular... on Green Fluorescent Protein Fluorescence. (December 2005) Vesela I. Chalova-Zhekova, Diplom., Higher Institute of Food and Flavor Industries Chair of Advisory Committee: Dr. Steven Ricke Lysine is one of the more limiting amino acids in protein...

Chalova-Zhekova, Vesela I.

2007-04-25T23:59:59.000Z

260

Design and implementation of a solar power system in rural Haiti  

E-Print Network [OSTI]

This paper describes the design and implementation of a solar power system for a school and health center in Petit-Anse, Haiti. The end-use applications are lighting via a set of fluorescent and incandescent bulbs, and a ...

Hussam, Shaheer M. (Shaheer Muqtasid), 1981-

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Plant Physiol. (1983) 73, 4504510 0032-0889/83/73/0450/02/$00.50/0  

E-Print Network [OSTI]

wrapped around 20-w cool white fluorescent tubes. For far-red light (730 nm peak, 15 nm half band width-w incandescent bulb was filtered through No. 2025 Plexiglas (Rohm and Hass, Inc.). Irradiance levels

Decoteau, Dennis R.

262

Energy 101: Lighting Choices | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

in your home to energy-saving incandescent, compact fluorescent lamp (CFL), or light emitting diode (LED) bulbs could save you about 50 per year. For more information on lighting...

263

Resolve to Save Energy This Year | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

STAR bulbs, you could save 75 a year in energy costs. Compared to traditional incandescent bulbs, compact fluorescent bulbs can yield as much as 75 percent energy savings and...

264

Commercialization of gallium nitride nanorod arrays on silicon for solid-state lighting  

E-Print Network [OSTI]

One important component in energy usage is lighting, which is currently dominated by incandescent and fluorescent lamps. However, due to potentially higher efficiencies and thus higher energy savings, solid-state lighting ...

Wee, Qixun

2008-01-01T23:59:59.000Z

265

2 Masers and Lasers January 31, 2008  

E-Print Network [OSTI]

, a candle, an incandescent bulb, or a fluorescent source, is the result of incoherent emission of light from of Radiation) that extended the existence of coherent sources right into the ultraviolet spectrum

Thouless, David

266

2011 Rutgers Faraday Children's Lecture Crew ReichertJon  

E-Print Network [OSTI]

;Continuous "black body spectrum" from incandescent light bulb hydrogen fluorescent light What they saw. ROY G. Disk jumps out of changing magnetic field region. Induced current lights bulb. #12;Prof. Chuck Keeton

Glashausser, Charles

267

Lesson Summary In this lesson, students will find and calculate the angle  

E-Print Network [OSTI]

white light source (incandescent light bulb, not fluorescent) · Copies of Astronomy Today or Sky of electromagnetic spectrum · Understanding of light and prisms · Experience with angle measurements · Experience

Mojzsis, Stephen J.

268

The Hazards of Use and Disposal of Compact Fluorescent Bulbs Compact fluorescent lights (aka. CFLs) work by exciting a phosphorous coating within the tube to emit  

E-Print Network [OSTI]

The Hazards of Use and Disposal of Compact Fluorescent Bulbs Compact fluorescent lights (aka. CFLs FLUORESCENT BULB? Because there is such a small amount of mercury in CFLs, the greatest hazard exposure the bulb to be an efficient light source. By comparison, older home thermometers contain 500 milligrams

Maroncelli, Mark

269

Cyanine-based probe\\tag-peptide pair fluorescence protein imaging and fluorescence protein imaging methods  

DOE Patents [OSTI]

A molecular probe comprises two arsenic atoms and at least one cyanine based moiety. A method of producing a molecular probe includes providing a molecule having a first formula, treating the molecule with HgOAc, and subsequently transmetallizing with AsCl.sub.3. The As is liganded to ethanedithiol to produce a probe having a second formula. A method of labeling a peptide includes providing a peptide comprising a tag sequence and contacting the peptide with a biarsenical molecular probe. A complex is formed comprising the tag sequence and the molecular probe. A method of studying a peptide includes providing a mixture containing a peptide comprising a peptide tag sequence, adding a biarsenical probe to the mixture, and monitoring the fluorescence of the mixture.

Mayer-Cumblidge, M. Uljana; Cao, Haishi

2013-01-15T23:59:59.000Z

270

Fluorescence-based optical glucose sensing  

E-Print Network [OSTI]

illustrated FITC/TRITC emission peaks . 15 23 24 Optical excitation and detection system featuring a light emitting diode source 27 pH effects on fluorophore peak emission intensities . . Temperature effects on individual fluorophores... restrictive; only lasers and a few light emitting diodes (LEDs) fall within this type of spectral output. A more general approach to defining the 16 source spectrum would be useful for those experimental setups with an arc lamp or other white light source...

Meledeo, Michael Adam

2012-06-07T23:59:59.000Z

271

Types of Costs Types of Cost Estimates  

E-Print Network [OSTI]

· Types of Costs · Types of Cost Estimates · Methods to estimate capital costs MIN E 408: Mining% accuracy. ­ 2-5% of pre-production capital Types of Cost Estimates #12;3. Definitive ­ Based on definitive-even $ Production Level Fixed Cost Break-even $ Production Level Cost-Revenue Relationships · Capital Costs (or

Boisvert, Jeff

272

Nuclear Resonance Fluorescence for Safeguards Applications  

SciTech Connect (OSTI)

In nuclear resonance fluorescence (NRF) measurements, resonances are excited by an external photon beam leading to the emission of {gamma} rays with specific energies that are characteristic of the emitting isotope. The promise of NRF as a non-destructive analysis technique (NDA) in safeguards applications lies in its potential to directly quantify a specific isotope in an assay target without the need for unfolding the combined responses of several fissile isotopes as often required by other NDA methods. The use of NRF for detection of sensitive nuclear materials and other contraband has been researched in the past. In the safeguards applications considered here one has to go beyond mere detection and precisely quantify the isotopic content, a challenge that is discussed throughout this report. Basic NRF measurement methods, instrumentation, and the analytical calculation of NRF signal strengths are described in Section 2. Well understood modeling and simulation tools are needed for assessing the potential of NRF for safeguards and for designing measurement systems. All our simulations were performed with the radiation transport code MCNPX, a code that is widely used in the safeguards community. Our initial studies showed that MCNPX grossly underestimated the elastically scattered background at backwards angles due to an incorrect treatment of Rayleigh scattering. While new, corrected calculations based on ENDF form factors showed much better agreement with experimental data for the elastic scattering of photons on an uranium target, the elastic backscatter is still not rigorously treated. Photonuclear scattering processes (nuclear Thomson, Delbruck and Giant Dipole Resonance scattering), which are expected to play an important role at higher energies, are not yet included. These missing elastic scattering contributions were studied and their importance evaluated evaluated against data found in the literature as discussed in Section 3. A transmission experiment was performed in September 2009 to test and demonstrate the applicability of the method to the quantitative measurement of an isotope of interest embedded in a thick target. The experiment, data analysis, and results are described in Section 4. The broad goal of our NRF studies is to assess the potential of the technique in safeguards applications. Three examples are analyzed in Section 5: the isotopic assay of spent nuclear fuel (SNF), the measurement of {sup 235}U enrichment in UF{sub 6} cylinders, and the determination of {sup 239}Pu in mixed oxide (MOX) fuel. The study of NRF for the assay of SNF assemblies was supported by the Next Generation Safeguards Initiative (NGSI) of the U.S. Department of Energy as part of a large multi-lab/university effort to quantify the plutonium (Pu) mass in spent nuclear fuel assemblies and to detect the diversion of pins with non-destructive assay (NDA) methods. NRF is one of 14 NDA techniques being researched. The methodology for performing and analyzing quantitative NRF measurements was developed for determining Pu mass in SNF and is extensively discussed in this report. The same methodology was applied to the assessment of NRF for the measurement of {sup 235}U enrichment and the determination of {sup 239}Pu in MOX fuel. The analysis centers on determining suitable NRF measurement methods, measurement capabilities that could be realized with currently available instrumentation, and photon source and detector requirements for achieving useful NDA capabilities.

Ludewigt, Bernhard A; Quiter, Brian J; Ambers, Scott D

2011-02-04T23:59:59.000Z

273

Fluorescent single walled nanotube/silica composite materials  

DOE Patents [OSTI]

Fluorescent composites of surfactant-wrapped single-walled carbon nanotubes (SWNTs) were prepared by exposing suspensions of surfactant-wrapped carbon nanotubes to tetramethylorthosilicate (TMOS) vapor. Sodium deoxycholate (DOC) and sodium dodecylsulphate (SDS) were the surfactants. No loss in emission intensity was observed when the suspension of DOC-wrapped SWNTs were exposed to the TMOS vapors, but about a 50% decrease in the emission signal was observed from the SDS-wrapped SWNTs nanotubes. The decrease in emission was minimal by buffering the SDS/SWNT suspension prior to forming the composite. Fluorescent xerogels were prepared by adding glycerol to the SWNT suspensions prior to TMOS vapor exposure, followed by drying the gels. Fluorescent aerogels were prepared by replacing water in the gels with methanol and then exposing them to supercritical fluid drying conditions. The aerogels can be used for gas sensing.

Dattelbaum, Andrew M.; Gupta, Gautam; Duque, Juan G.; Doorn, Stephen K.; Hamilton, Christopher E.; DeFriend Obrey, Kimberly A.

2013-03-12T23:59:59.000Z

274

BIOCOMPATIBLE FLUORESCENT MICROSPHERES: SAFE PARTICLES FOR MATERIAL PENETRATION STUDIES  

SciTech Connect (OSTI)

Biocompatible polymers with hydrolyzable chemical bonds have been used to produce safe, non-toxic fluorescent microspheres for material penetration studies. The selection of polymeric materials depends on both biocompatibility and processability, with tailored fluorescent properties depending on specific applications. Microspheres are composed of USFDA-approved biodegradable polymers and non-toxic fluorophores and are therefore suitable for tests where human exposure is possible. Micropheres were produced which contain unique fluorophores to enable discrimination from background aerosol particles. Characteristics that affect dispersion and adhesion can be modified depending on use. Several different microsphere preparation methods are possible, including the use of a vibrating orifice aerosol generator (VOAG), a Sono-Tek atomizer, an emulsion technique, and inkjet printhead. Applications for the fluorescent microspheres include challenges for biodefense system testing, calibrants for biofluorescence sensors, and particles for air dispersion model validation studies.

Farquar, G; Leif, R

2009-07-15T23:59:59.000Z

275

Laser-induced differential normalized fluorescence method for cancer diagnosis  

DOE Patents [OSTI]

An apparatus and method for cancer diagnosis are disclosed. The diagnostic method includes the steps of irradiating a tissue sample with monochromatic excitation light, producing a laser-induced fluorescence spectrum from emission radiation generated by interaction of the excitation light with the tissue sample, and dividing the intensity at each wavelength of the laser-induced fluorescence spectrum by the integrated area under the laser-induced fluorescence spectrum to produce a normalized spectrum. A mathematical difference between the normalized spectrum and an average value of a reference set of normalized spectra which correspond to normal tissues is calculated, which provides for amplifying small changes in weak signals from malignant tissues for improved analysis. The calculated differential normalized spectrum is correlated to a specific condition of a tissue sample. 5 figs.

Vo-Dinh, T.; Panjehpour, M.; Overholt, B.F.

1996-12-03T23:59:59.000Z

276

Laser-induced differential normalized fluorescence method for cancer diagnosis  

DOE Patents [OSTI]

An apparatus and method for cancer diagnosis are disclosed. The diagnostic method includes the steps of irradiating a tissue sample with monochromatic excitation light, producing a laser-induced fluorescence spectrum from emission radiation generated by interaction of the excitation light with the tissue sample, and dividing the intensity at each wavelength of the laser-induced fluorescence spectrum by the integrated area under the laser-induced fluorescence spectrum to produce a normalized spectrum. A mathematical difference between the normalized spectrum and an average value of a reference set of normalized spectra which correspond to normal tissues is calculated, which provides for amplifying small changes in weak signals from malignant tissues for improved analysis. The calculated differential normalized spectrum is correlated to a specific condition of a tissue sample.

Vo-Dinh, Tuan (Knoxville, TN); Panjehpour, Masoud (Knoxville, TN); Overholt, Bergein F. (Knoxville, TN)

1996-01-01T23:59:59.000Z

277

A versatile detector for total fluorescence and electron yield experiments  

SciTech Connect (OSTI)

The combination of a non-coated silicon photodiode with electron repelling meshes makes a versatile detector for total fluorescence yield and electron yield techniques highly suitable for x-ray absorption spectroscopy. In particular, a copper mesh with a bias voltage allows to suppress or transmit the electron yield signal. The performance of this detection scheme has been characterized by near edge x-ray absorption fine structure studies of thermal oxidized silicon and sapphire. The results show that the new detector probes both electron yield and for a bias voltage exceeding the maximum photon energy the total fluorescence yield.

Thielemann, N. [Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Institut fuer Physik, Humboldt-Universitaet zu Berlin, Newtonstrasse 15, 12489 Berlin (Germany); Hoffmann, P. [Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Foehlisch, A. [Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Institut fuer Physik und Astronomie, Universitaet Potsdam, Karl-Liebknecht-Strasse 24-25, 14476 Potsdam (Germany)

2012-09-15T23:59:59.000Z

278

Heat transfer assembly for a fluorescent lamp and fixture  

DOE Patents [OSTI]

In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure.

Siminovitch, Michael J. (Richmond, CA); Rubenstein, Francis M. (Berkeley, CA); Whitman, Richard E. (Richmond, CA)

1992-01-01T23:59:59.000Z

279

Heat transfer assembly for a fluorescent lamp and fixture  

DOE Patents [OSTI]

In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.

Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.

1992-12-29T23:59:59.000Z

280

3D optical sectioning with a new hyperspectral confocal fluorescence imaging system.  

SciTech Connect (OSTI)

A novel hyperspectral fluorescence microscope for high-resolution 3D optical sectioning of cells and other structures has been designed, constructed, and used to investigate a number of different problems. We have significantly extended new multivariate curve resolution (MCR) data analysis methods to deconvolve the hyperspectral image data and to rapidly extract quantitative 3D concentration distribution maps of all emitting species. The imaging system has many advantages over current confocal imaging systems including simultaneous monitoring of numerous highly overlapped fluorophores, immunity to autofluorescence or impurity fluorescence, enhanced sensitivity, and dramatically improved accuracy, reliability, and dynamic range. Efficient data compression in the spectral dimension has allowed personal computers to perform quantitative analysis of hyperspectral images of large size without loss of image quality. We have also developed and tested software to perform analysis of time resolved hyperspectral images using trilinear multivariate analysis methods. The new imaging system is an enabling technology for numerous applications including (1) 3D composition mapping analysis of multicomponent processes occurring during host-pathogen interactions, (2) monitoring microfluidic processes, (3) imaging of molecular motors and (4) understanding photosynthetic processes in wild type and mutant Synechocystis cyanobacteria.

Nieman, Linda T.; Sinclair, Michael B.; Davidson, George S.; Van Benthem, Mark Hilary; Haaland, David Michael; Timlin, Jerilyn Ann; Sasaki, Darryl Yoshio; Bachand, George David; Jones, Howland D. T.

2007-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Spotlights on Recent JACS Publications FLUORESCENT PROBES LIGHT UP AMYLOID  

E-Print Network [OSTI]

the conductance, or transport, of ions across the membrane. Researchers have exploited the efficient transport investigated the mechanism of ion transport through several structural variants of fluorescent oligoester: the channel's ion transport activity slowly decreased over time. The researchers used steady-state and time

Theodorakis, Emmanuel

282

A genetically encoded fluorescent reporter of ATP:ADP ratio  

E-Print Network [OSTI]

A genetically encoded fluorescent reporter of ATP:ADP ratio Jim Berg1,2, Yin Pun Hung1 & Gary's affinity for Mg-ATP was o100 nM, as seen for other members of the bacterial PII regulator family, a surprisingly high affinity given that normal intracellular ATP concentration is in the millimolar range. ADP

Yellen, Gary

283

Stepwise Quenching of Exciton Fluorescence in Carbon Nanotubes  

E-Print Network [OSTI]

1 Stepwise Quenching of Exciton Fluorescence in Carbon Nanotubes by Single Molecule Reactions with individual single-walled carbon nanotubes are observed, and luminescence quenching analysis reveals the diffusional range of excitons in semiconducting nanotubes. *To whom correspondence should be addressed

Paris-Sud XI, Université de

284

Automated hybridization/imaging device for fluorescent multiplex DNA sequencing  

DOE Patents [OSTI]

A method is disclosed for automated multiplex sequencing of DNA with an integrated automated imaging hybridization chamber system. This system comprises an hybridization chamber device for mounting a membrane containing size-fractionated multiplex sequencing reaction products, apparatus for fluid delivery to the chamber device, imaging apparatus for light delivery to the membrane and image recording of fluorescence emanating from the membrane while in the chamber device, and programmable controller apparatus for controlling operation of the system. The multiplex reaction products are hybridized with a probe, the enzyme (such as alkaline phosphatase) is bound to a binding moiety on the probe, and a fluorogenic substrate (such as a benzothiazole derivative) is introduced into the chamber device by the fluid delivery apparatus. The enzyme converts the fluorogenic substrate into a fluorescent product which, when illuminated in the chamber device with a beam of light from the imaging apparatus, excites fluorescence of the fluorescent product to produce a pattern of hybridization. The pattern of hybridization is imaged by a CCD camera component of the imaging apparatus to obtain a series of digital signals. These signals are converted by the controller apparatus into a string of nucleotides corresponding to the nucleotide sequence an automated sequence reader. The method and apparatus are also applicable to other membrane-based applications such as colony and plaque hybridization and Southern, Northern, and Western blots. 9 figs.

Weiss, R.B.; Kimball, A.W.; Gesteland, R.F.; Ferguson, F.M.; Dunn, D.M.; Di Sera, L.J.; Cherry, J.L.

1995-11-28T23:59:59.000Z

285

Automated hybridization/imaging device for fluorescent multiplex DNA sequencing  

DOE Patents [OSTI]

A method is disclosed for automated multiplex sequencing of DNA with an integrated automated imaging hybridization chamber system. This system comprises an hybridization chamber device for mounting a membrane containing size-fractionated multiplex sequencing reaction products, apparatus for fluid delivery to the chamber device, imaging apparatus for light delivery to the membrane and image recording of fluorescence emanating from the membrane while in the chamber device, and programmable controller apparatus for controlling operation of the system. The multiplex reaction products are hybridized with a probe, then an enzyme (such as alkaline phosphatase) is bound to a binding moiety on the probe, and a fluorogenic substrate (such as a benzothiazole derivative) is introduced into the chamber device by the fluid delivery apparatus. The enzyme converts the fluorogenic substrate into a fluorescent product which, when illuminated in the chamber device with a beam of light from the imaging apparatus, excites fluorescence of the fluorescent product to produce a pattern of hybridization. The pattern of hybridization is imaged by a CCD camera component of the imaging apparatus to obtain a series of digital signals. These signals are converted by the controller apparatus into a string of nucleotides corresponding to the nucleotide sequence an automated sequence reader. The method and apparatus are also applicable to other membrane-based applications such as colony and plaque hybridization and Southern, Northern, and Western blots.

Weiss, Robert B. (Salt Lake City, UT); Kimball, Alvin W. (Salt Lake City, UT); Gesteland, Raymond F. (Salt Lake City, UT); Ferguson, F. Mark (Salt Lake City, UT); Dunn, Diane M. (West Valley City, UT); Di Sera, Leonard J. (Salt Lake City, UT); Cherry, Joshua L. (Salt Lake City, UT)

1995-01-01T23:59:59.000Z

286

REGULAR PAPER Modulation of the fluorescence yield in heliobacterial cells  

E-Print Network [OSTI]

. They are thought to use a light-driven cyclic electron transport pathway to pump protons, and thereby phos brief flashes is inversely correlated to the variable fluorescence. Using pump-probe spectros- copy), or conversion to heat. When photosynthetic systems are operating efficiently, photochemistry dominates

287

Actin Polymerization Overshoots and Hydrolysis as Assayed by Pyrene Fluorescence  

E-Print Network [OSTI]

Actin Polymerization Overshoots and Hydrolysis as Assayed by Pyrene Fluorescence F. J. Brooks and A observed in the flu- orescence intensity of pyrene-labeled actin during rapid polymerization. We show the true polymerization kinetics. We show that there is an optimal range of hydrolysis and phosphate

Carlsson, Anders

288

Optical gating of perylene bisimide fluorescence using dithienylcyclopentene photochromic switches  

SciTech Connect (OSTI)

The emission of millions of fluorescence photons from a chromophore is controlled by the absorption of a few tens of photons in a photochromic molecule. The parameters that determine the efficiency of this process are investigated, providing insights for the development of an all-optical gate.

Pärs, Martti; Köhler, Jürgen, E-mail: juergen.koehler@uni-bayreuth.de [Experimental Physics IV, University of Bayreuth, 95440 Bayreuth (Germany)] [Experimental Physics IV, University of Bayreuth, 95440 Bayreuth (Germany); Gräf, Katja; Bauer, Peter; Thelakkat, Mukundan [Applied Functional Polymers, University of Bayreuth, 95440 Bayreuth (Germany)] [Applied Functional Polymers, University of Bayreuth, 95440 Bayreuth (Germany)

2013-11-25T23:59:59.000Z

289

Classification of Protein Localization Patterns Obtained via Fluorescence Light Microscopy  

E-Print Network [OSTI]

of the microscope. They should also be in- sensitive to the wide variability in cell morphology that is present in fluores- cence light microscope images of mammalian cells. Such images are generated on a regular basis by labeling one or more subcellular structures with fluorescent dyes and then collecting images

Gordon, Geoffrey J.

290

Fluorescent lamp with static magnetic field generating means  

DOE Patents [OSTI]

A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed. 2 figs.

Moskowitz, P.E.; Maya, J.

1987-09-08T23:59:59.000Z

291

BIOCOMPATIBLE FLUORESCENT MICROSPHERES: SAFE PARTICLES FOR MATERIAL PENETRATION STUDIES  

SciTech Connect (OSTI)

Biocompatible polymers with hydrolyzable chemical bonds are being used to produce safe, non-toxic fluorescent microspheres for material penetration studies. The selection of polymeric materials depends on both biocompatibility and processability, with tailored fluorescent properties depending on specific applications. Microspheres are composed of USFDA-approved biodegradable polymers and non-toxic fluorophores and are therefore suitable for tests where human exposure is possible. Micropheres are being produced which contain unique fluorophores to enable discrimination from background aerosol particles. Characteristics that affect dispersion and adhesion can be modified depending on use. Several different microsphere preparation methods are possible, including the use of a vibrating orifice aerosol generator (VOAG), a Sono-Tek atomizer, an emulsion technique, and inkjet printhead. The advantages and disadvantages of each method will be presented and discussed in greater detail along with fluorescent and charge properties of the aerosols. Applications for the fluorescent microspheres include challenges for biodefense system testing, calibrants for biofluorescence sensors, and particles for air dispersion model validation studies.

farquar, G; Leif, R

2008-09-12T23:59:59.000Z

292

Cellubrevin-targeted Fluorescence Uncovers Heterogeneity in the Recycling Endosomes*  

E-Print Network [OSTI]

Cellubrevin-targeted Fluorescence Uncovers Heterogeneity in the Recycling Endosomes* (Received, University of California, Berkeley, California 94720-3200 The pH and trafficking of recycling endosomes have-enriched recycling endosomes (pHCb) and FITC-transferrin to measure the pH of transferrin- enriched recycling

Machen, Terry E.

293

Fluorescent Amino Acids: Modular Building Blocks for the Assembly of New Tools for Chemical Biology  

E-Print Network [OSTI]

Fluorescence spectroscopy is a powerful tool for probing complex biological processes. The ubiquity of peptide–protein and protein–protein interactions in these processes has made them important targets for fluorescence ...

Krueger, Andrew T.

294

Extending the utility of enzymes for site-specific targeting of fluorescent probes  

E-Print Network [OSTI]

Genetically encodable fluorescence reporters such as the green fluorescent protein (GFP) are useful for studying protein expression, localization, and dynamics in a variety of biological systems. GFP and its related variants, ...

Liu, Daniel S. (Daniel Shao-Chen)

2014-01-01T23:59:59.000Z

295

Understanding Zinc Quantification with Existing and Advanced Ditopic Fluorescent Zinpyr Sensors  

E-Print Network [OSTI]

Treatment of aqueous zinc solutions with incremental additions of a ditopic fluorescent sensor of the Zinpyr family, based on pyridine/pyrazine-containing metal recognition units, affords a fluorescence titration curve ...

Buccella, Daniela

296

Seminaphthofluorescein-Based Fluorescent Probes for Imaging Nitric Oxide in Live Cells  

E-Print Network [OSTI]

Fluorescent turn-on probes for nitric oxide based on seminaphthofluorescein scaffolds were prepared and spectroscopically characterized. The Cu(II) complexes of these fluorescent probes react with NO under anaerobic ...

Pluth, Michael D.

297

Detection of counterfeit U.S. paper money using intrinsic fluorescence lifetime  

E-Print Network [OSTI]

-photon spectral and lifetime fluorescence microscopy," Appl. Opt. 43(27), 5173­5182 (2004). #118121 - $15.00 USD

Levene, Michael J.

298

Types of Costs Types of Cost Estimates  

E-Print Network [OSTI]

05-1 · Types of Costs · Types of Cost Estimates · Methods to estimate capital costs MIN E 408-Revenue Relationships · Capital Costs (or first cost or capital investment): ­ Expenditures made to acquire or develop capital assets ­ Three main classes of capital costs: 1. Depreciable Investment: · Investment allocated

Boisvert, Jeff

299

Fluorescent Probe Solubilization in the Headgroup and Core Regions of Micelles: Fluorescence Lifetime and Orientational Relaxation Measurements  

E-Print Network [OSTI]

the microheterogeneous medium under investigation. To ascertain that the probe is located in the target environment in the hydrocarbon core region of the micelle. In this environment the chromophores have a considerably longer to be applied successfully, the fluorescent molecule must be tailored to probe the desired environment within

Fayer, Michael D.

300

Fluorescence quenching of water-soluble porphyrins. A novel fluorescence quenching of anionic porphyrin by anionic anthraquinone  

SciTech Connect (OSTI)

The fluorescence quenching of 5-phenyl-10,15,20-tris(p-sulfonatophenyl)porphine (TPPS/sup 3 -/) and 5,10,15,20-tetrakis(4-N-methylpyridyl)porphine (TMPyP/sup 4 +/) has been studied in water (pH 8.0) by using 9,10-anthra-quinone-2,6-disulfonate (AQDS/sup 2 -/) and methyl viologen (MV/sup 2 +/) as quenchers. While electrostatic repulsion is expected, AQDS/sup 2 -/ quenched the TPPS/sup 3 -/ fluorescence more efficiently than MV/sup 2 +/. The steady-state and time-resolved fluorescence measurements indicated that static quenching took place in the TPPS/sup 3 -/-AQDS/sup 2 -/ system. Studies on the absorption spectra and the effects of ionic strength on the fluorescence quenching indicated the formation of the ground-state complex of TPPS/sup 3 -/ and AQDS/sup 2 -/. The thermodynamic parameters (..delta..H and ..delta..S) suggested that the ground-state complex was formed via van der Walls interaction.

Kano, K.; Sato, T.; Yamada, S.; Ogawa, T.

1983-02-17T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

428 BIOCHIMICAET BIOPHYSICAACTA pH CONTROL OF THE CHLOROPHYLL a FLUORESCENCE IN ALGAE  

E-Print Network [OSTI]

428 BIOCHIMICAET BIOPHYSICAACTA BBA 46126 pH CONTROL OF THE CHLOROPHYLL a FLUORESCENCE IN ALGAE on the "slow" (min) time course of Chlorophyll a fluorescence yield in the green alga Chlorella pyrenoidosa and in the blue-green alga Anacystis nidulans. In Chlorella, the decay of fluorescence yield, in the I- to 5-rain

Govindjee

302

Caged Molecular Fluorescence Velocimetry to measure meso-to micro-scale thermal flow fields  

E-Print Network [OSTI]

(CPL). The system utilizes a microscope objective lens, caged molecular fluorescence probes, Nd:YAG laser for UV light source, Ar-ion laser for 488 nm fluorescence pumping, and a color CCD camera to record a series of fluorescent images. Caged...

Park, Jaesung

2000-01-01T23:59:59.000Z

303

DNA complexes with dyes designed for energy transfer as fluorescent markers  

DOE Patents [OSTI]

Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.

Glazer, Alexander M. (Orinda, CA); Benson, Scott C. (Albany, CA)

1999-01-01T23:59:59.000Z

304

Bioluminescent and Red-Fluorescent Lures in a Deep-Sea Siphonophore  

E-Print Network [OSTI]

Bioluminescent and Red-Fluorescent Lures in a Deep-Sea Siphonophore Steven H. D. Haddock,1 * Casey stalk (Fig. 1, B and C). The transpar- ent stalk terminates in a bulb containing white spots, historical surrounded by red fluorescent material (Fig. 1C). This substance produced a multimodal fluorescence emis

Dunn, Casey

305

RAPID COMMUNICATION An Integral Membrane Green Fluorescent Protein Marker, Us9-GFP,  

E-Print Network [OSTI]

RAPID COMMUNICATION An Integral Membrane Green Fluorescent Protein Marker, Us9-GFP described GFP-spectrin, a membrane- localized derivative of the green fluorescent protein that can proteins employed in this assay. © 1999 Academic Press Key Words: green fluorescent protein; cell cycle

306

Fluorescence Behavioral Imaging (FBI) Tracks Identity in Heterogeneous Groups of Drosophila  

E-Print Network [OSTI]

Fluorescence Behavioral Imaging (FBI) Tracks Identity in Heterogeneous Groups of Drosophila Pavan describe Fluorescence Behavioral Imaging (FBI), a toolkit that uses transgenic fluorescence to discriminate-source software for automated, high-accuracy determination of genetic identity. Using FBI, we measure courtship

Floreano, Dario

307

On the advantages of using green light to study fluorescence yield changes in leaves  

E-Print Network [OSTI]

) and the Benson and Calvin cycle involved in the fixation of CO2 (see e.g. [5]). The large variety of parameters the fluorescence increase reflecting the full reduction of the plastoquinone pool. We ascribe this plateau of the light-induced changes of fluorescence yield. In order to detect fluorescence emission, the sample has

308

RPI students supporting education outreach Target Audience: Elementary school students (grades 3-6)  

E-Print Network [OSTI]

) Lowe's or Home Depot Approx. $22.00 each Compact Fluorescent Bulb 40 Lumen equivalent (GE) Lowe Introduction and Bulb Comparison; LED, Compact Fluorescent, Incandescent Bulb Comparison #12;Resistor Kit (incl (top position), compact fluorescent (middle position), LED Bulb (lower position). Computer set up

Linhardt, Robert J.

309

The Problem Conventional office lighting typically consists of bright fluo-  

E-Print Network [OSTI]

and undercabinet lights combined with incandescent or fluorescent task lights. This approach is not very energy-friendly, high-quality light- ing with a number of benefits. Reduced waste from fluorescent lights. Fluorescent, an already-efficient lighting system can save even more energy. If an employee leaves the office and forgets

310

DNA fragment sizing and sorting by laser-induced fluorescence  

DOE Patents [OSTI]

A method is provided for sizing DNA fragments using high speed detection systems, such as flow cytometry to determine unique characteristics of DNA pieces from a sample. In one characterization the DNA piece is fragmented at preselected sites to produce a plurality of DNA fragments. The DNA piece or the resulting DNA fragments are treated with a dye effective to stain stoichiometrically the DNA piece or the DNA fragments. The fluorescence from the dye in the stained fragments is then examined to generate an output functionally related to the number of nucleotides in each one of the DNA fragments. In one embodiment, the intensity of the fluorescence emissions from each fragment is linearly related to the fragment length. The distribution of DNA fragment sizes forms a characterization of the DNA piece for use in forensic and research applications.

Hammond, Mark L. (Angier, NC); Jett, James H. (Los Alamos, NM); Keller, Richard A. (Los Alamos, NM); Marrone, Babetta L. (Los Alamos, NM); Martin, John C. (Los Alamos, NM)

1996-01-01T23:59:59.000Z

311

Fluorescence quenching of CdSe quantum dots on graphene  

SciTech Connect (OSTI)

We studied systematically the fluorescence quenching of CdSe quantum dots (QDs) on graphene and its multilayers, as well as graphene oxide (GO) and reduced graphene oxide (rGO). Raman intensity of QDs was used as a quantitatively measurement of its concentration in order to achieve a reliable quenching factor (QF). It was found that the QF of graphene (?13.1) and its multilayers is much larger than rGO (?4.4), while GO (?1.5) has the lowest quenching efficiency, which suggests that the graphitic structure is an important factor for quenching the fluorescence of QDs. It was also revealed that the QF of graphene is not strongly dependent on its thicknesses.

Guo, Xi Tao; Hua Ni, Zhen, E-mail: zhni@seu.edu.cn; Yan Nan, Hai; Hui Wang, Wen [Department of Physics and Key Laboratory of MEMS of the Ministry of Education, Southeast University, Nanjing 211189 (China)] [Department of Physics and Key Laboratory of MEMS of the Ministry of Education, Southeast University, Nanjing 211189 (China); Yan Liao, Chun [Physics Department, National Photoelectric Technology and Functional Materials and Application of Science and Technology International Cooperation Base, Northwest University, Xi'an 710069 (China)] [Physics Department, National Photoelectric Technology and Functional Materials and Application of Science and Technology International Cooperation Base, Northwest University, Xi'an 710069 (China); Zhang, Yan; Wei Zhao, Wei [Jiangsu Key Laboratory for Design and Fabrication of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing 211189 (China)] [Jiangsu Key Laboratory for Design and Fabrication of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing 211189 (China)

2013-11-11T23:59:59.000Z

312

Magnetic fluorescent lamp having reduced ultraviolet self-absorption  

DOE Patents [OSTI]

The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly (10) is enhanced by providing means (30) for establishing a magnetic field with lines of force along the path of electron flow through the bulb (12) of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

Berman, Samuel M. (San Francisco, CA); Richardson, Robert W. (Pelham, NY)

1985-01-01T23:59:59.000Z

313

Dynamic fluorescence imaging with molecular agents for cancer detection  

E-Print Network [OSTI]

emission computed tomography SUV standard uptake values SLN sentinel lymph node TK tyrosine kinase TBR target to background ratio Symbols ? pharmacokinetic parameter ? pharmacokinetic parameter )(tC BOUND concentration of dye... bound to integrin receptor either in the vascular or extravascular compartments )(tC LAREXTRAVASCU concentration of dye in extravascular space )(tC VASCULAR concentration of dye in vascular space 0 I background fluorescence intensity c k...

Kwon, Sun Kuk

2009-05-15T23:59:59.000Z

314

Photon statistics of atomic fluorescence after {pi}-pulse excitation  

SciTech Connect (OSTI)

The photon statistics of atomic fluorescence after {pi}-pulse excitation is investigated in a system in which the input and output ports are connected to an atom. Since spontaneous decay during input pulse excitation occurs, the output pulse generally contains a multiphoton component with a certain probability. We quantitatively evaluate the probability of the output pulse containing multiple photons and determine the conditions for ideal single-photon generation.

Yoshimi, Kazuyoshi [College of Liberal Arts and Sciences, Tokyo Medical and Dental University, Ichikawa, Chiba 272-0827 (Japan); Koshino, Kazuki [College of Liberal Arts and Sciences, Tokyo Medical and Dental University, Ichikawa, Chiba 272-0827 (Japan); PRESTO, Japan Science and Technology Agency, Kawaguchi, Saitama 332-0012 (Japan)

2010-09-15T23:59:59.000Z

315

Development of a fluorescent antibody test for equine infectious anemia  

E-Print Network [OSTI]

. Moore The development of a direct fluorescent antibody technique for a reliable laboratory and diagnostic test for equine infectious anemia (EIA) was described. A specific antiserum was produced by inoculation of goats with EIA virus derived from... the Texas and Illinois strains of EIA virus in cell culture and in known infected horses and against the Wyoming strain of EIA virus in inoculated horses. Its specificity was further substantiated by testing it against heterologous viruses including...

Lester, Thomas Lee

1972-01-01T23:59:59.000Z

316

Microwave-Assisted Synthesis of Fluorescent Carbon Nanoparticles  

E-Print Network [OSTI]

MICROWAVE-ASSITED SYNTHESIS OF FLUORESCENT CARBON NANOPARTICLES A Thesis by BONNIE CHEN Submitted to the Office of Graduate and Professional Studies of Texas A&M University in partial fulfillment of the requirements for the degree...-(hydroxymethyl) furfural (5- HMF) derivatives, which are major products of glucose decomposition. iv ACKNOWLEDGEMENTS This thesis was completed in my fourth year at Texas A&M University as a master's student, and analyzes, discusses and displays...

Chen, Bonnie

2014-08-19T23:59:59.000Z

317

Types of Reuse  

Broader source: Energy.gov [DOE]

The following provides greater detail regarding the types of reuse pursued for LM sites. It should be noted that many actual reuses combine several types of the uses listed below.

318

Enhanced detection of fluorescence quenching in labeled cells  

DOE Patents [OSTI]

A method is provided for quantifying BrdU labeled DNA in cells. The BrdU is substituted onto the DNA and the DNA is stained with a first fluorochrome having a fluorescence which is quenchable by BrdU. The first fluorochrome is preferably a thymidine base halogen analogue, such as a Hoechst fluorochrome. The DNA is then stained with a second fluorochrome having a fluorescence which is substantially uneffected by BrdU. The second fluorochrome may be selected from the group consisting of mithramycin, chromomycin A3, olivomycin, propidium iodide and ethidium bromine. The fluorescence from the first and second fluorochromes is then measured to obtain first and second output signals, respectively. The first output signal is subtracted from the second output signal to obtain a difference signal which is functionally related to the quantity of BrdU incorporated into DNA. The technique is particularly useful for quantifying the synthesis of DNA during the S-phase of the cell cycle. 2 figs.

Crissman, H.A.; Steinkamp, J.A.

1987-11-30T23:59:59.000Z

319

Lighting Market Sourcebook for the U.S.  

E-Print Network [OSTI]

2.1.4. Residential Lamp Types 2.1.5. Wattage, Hours of Use,all lamp types (mostly incandescent) in all other wattageWattage Category Energy Use (hours per day) lamp types)

Vorsatz, D.; Shown, L.; Koomey, J.; Moezzi, M.; Denver, A.; Atkinson, B.

1997-01-01T23:59:59.000Z

320

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

SciTech Connect (OSTI)

Lighting has been one of the fastest growing electric end-uses in China over the last twenty years, with an average annual growth rate of 14%. Fluorescent lighting provides a significant portion of China's lighting need. In 1998, China produced 680 million fluorescent lamps, of which 420 million were linear fluorescent lamps of various diameters (T8 to T12). There are substantial variations both in energy efficiency and lighting performance among locally produced fluorescent lamps. Such variations present a perfect opportunity for policy intervention through efficiency standards to promote the adoption of more efficient fluorescent lamps in China. This paper analyzes China's proposed minimum efficiency standard for fluorescent lamps and presents an assessment of its likely impacts on China's lighting energy consumption and GHG emissions.

Lin, Jiang

2002-04-11T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

X-ray fluorescence spectroscopy from ions at charged vapor/water interfaces  

E-Print Network [OSTI]

X-ray fluorescence spectra from monovalent ions (Cs+) that accumulate from dilute solutions to form an ion-rich layer near a charged Langmuir monolayer are presented. For the salt solution without the monolayer, the fluorescence signals below the critical angle are significantly lower than the detection sensitivity and only above the critical angle signals from the bulk are observed. In the presence of a monolayer that provides surface charges, strong fluorescence signals below the critical angle are observed. Ion density accumulated at the interface are determined from the fluorescence. The fluorescent spectra collected as a function of incident x-ray energy near the LIII edge yield the extended absorption spectra from the ions, and are compared to recent independent results. The fluorescence data from divalent Ba2+ with and without monolayer are also presented.

Wei Bu; David Vaknin

2009-05-04T23:59:59.000Z

322

Nanoscale fluorescence lifetime imaging with a single diamond NV center  

E-Print Network [OSTI]

Solid-state quantum emitters, such as artificially engineered quantum dots or naturally occurring defects in solids, are being investigated for applications ranging from quantum information science and optoelectronics to biomedical imaging. Recently, these same systems have also been studied from the perspective of nanoscale metrology. In this letter we study the near-field optical properties of a diamond nanocrystal hosting a single nitrogen vacancy center. We find that the nitrogen vacancy center is a sensitive probe of the surrounding electromagnetic mode structure. We exploit this sensitivity to demonstrate nanoscale fluorescence lifetime imaging microscopy (FLIM) with a single nitrogen vacancy center by imaging the local density of states of an optical antenna.

Ryan Beams; Dallas Smith; Timothy W. Johnson; Sang-Hyun Oh; Lukas Novotny; Nick Vamivakas

2013-03-05T23:59:59.000Z

323

Quantum Process Tomography by 2D Fluorescence Spectroscopy  

E-Print Network [OSTI]

Reconstruction of the dynamics (quantum process tomography) of the single-exciton manifold in energy transfer systems is proposed here on the basis of two-dimensional fluorescence spectroscopy (2D-FS) with phase-modulation. The quantum-process-tomography protocol introduced here benefits from, e.g., the sensitivity enhancement and signal-to-noise ratio ascribed to 2D-FS. Although the isotropically averaged spectroscopic signals depend on the quantum yield parameter $\\Gamma$ of the doubly-excited-exciton manifold, it is shown that the reconstruction of the dynamics is insensitive to this parameter. Applications to foundational and applied problems, as well as further extensions, are discussed.

Leonardo A. Pachon; Andrew H. Marcus; Alan Aspuru-Guzik

2015-02-09T23:59:59.000Z

324

Quantum Process Tomography by 2D Fluorescence Spectroscopy  

E-Print Network [OSTI]

Reconstruction of the dynamics (quantum process tomography) of the single-exciton manifold in energy transfer systems is proposed here on the basis of two-dimensional fluorescence spectroscopy (2D-FS) with phase-modulation. The quantum-process-tomography protocol introduced here benefits from, e.g., the sensitivity enhancement and signal-to-noise ratio ascribed to 2D-FS. Although the isotropically averaged spectroscopic signals depend on the quantum yield parameter $\\Gamma$ of the doubly-excited-exciton manifold, it is shown that the reconstruction of the dynamics is insensitive to this parameter. Applications to foundational and applied problems, as well as further extensions, are discussed.

Pachon, Leonardo A; Aspuru-Guzik, Alan

2015-01-01T23:59:59.000Z

325

Blue-green phosphor for fluorescent lighting applications  

DOE Patents [OSTI]

A fluorescent lamp including a phosphor layer including Sr.sub.4 Al.sub.14 O.sub.25 :Eu.sup.2+ (SAE) and at least one of each of a red, green and blue emitting phosphor. The phosphor layer can optionally include an additional, deep red phosphor and a yellow emitting phosphor. The resulting lamp will exhibit a white light having a color rendering index of 90 or higher with a correlated color temperature of from 2500 to 10000 Kelvin. The use of SAE in phosphor blends of lamps results in high CRI light sources with increased stability and acceptable lumen maintenance over, the course of the lamp life.

Srivastava, Alok; Comanzo, Holly; Manivannan, Venkatesan; Setlur, Anant Achyut

2005-03-15T23:59:59.000Z

326

Feedback control of the squeezing of the fluorescence light  

E-Print Network [OSTI]

Among the formulations of the theory of quantum measurements in continuous time, quantum trajectory theory is very suitable for the introduction of measurement based feedback and closed loop control of quantum systems. In this paper we present such a construction in the concrete case of a two-level atom stimulated by a coherent, monochromatic laser. In particular, we show how fast feedback \\`a la Wiseman and Milburn can be introduced in the formulation of the theory. Then, the spectrum of the free fluorescence light is studied and typical quantum phenomena, squeezing and sub-natural line-narrowing, are presented.

Alberto Barchielli; Matteo Gregoratti

2009-10-09T23:59:59.000Z

327

Fluorescent Pigments for High-Performance Cool Roofing  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecordFederal7.pdfFlash_2010_-24.pdfOverview Flow Cells forFluorescent

328

Fluorescence of [Fe II] in H II regions  

E-Print Network [OSTI]

A study of [Fe II] lines at various positions within the H II regions M42 and M43 is presented. The relative intensities of selected optical [Fe II] lines are shown to be correlated with the intensity of the apparent nebular continuous spectrum. Since the continuum of H II regions is known to be mostly stellar radiation scattered by dust intermixed with the emitting gas, these correlations provide direct evidence for the existence of fluorescent excitation in the formation process of the [Fe II] lines, irrespective of the prevailing physical state.

M. Rodriguez

1999-06-17T23:59:59.000Z

329

Product Standards for Fluorescent Lighting (Japan) | Open Energy  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth'sOklahoma/GeothermalOrangePeru:JobInformationInformation Fluorescent

330

X-Ray Fluorescence (XRF) | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to:SeadovCooperative JumpWilliamsonWoodsonCounty is a county in NewFluorescence (XRF) Jump

331

Rock types, pore types, and hydrocarbon exploration  

SciTech Connect (OSTI)

A proposed exploration-oriented method of classifying porosity in sedimentary rocks is based on microscopic examination cores or cuttings. Factors include geometry, size, abundance, and connectivity of the pores. The porosity classification is predictive of key petrophysical characteristics: porosity-permeability relationships, capillary pressures, and (less certainly) relative permeabilities. For instance, intercrystalline macroporosity typically is associated with high permeability for a given porosity, low capillarity, and favorable relative permeabilities. This is found to be true whether this porosity type occurs in a sucrosic dolomite or in a sandstone with pervasive quartz overgrowths. This predictive method was applied in three Rocky Mountain oil plays. Subtle pore throat traps could be recognized in the J sandstone (Cretaceous) in the Denver basin of Colorado by means of porosity permeability plotting. Variations in hydrocarbon productivity from a Teapot Formation (Cretaceous) field in the Powder River basin of Wyoming were related to porosity types and microfacies; the relationships were applied to exploration. Rock and porosity typing in the Red River Formation (Ordovician) reconciled apparent inconsistencies between drill-stem test, log, and mud-log data from a Williston basin wildcat. The well was reevaluated and completed successfully, resulting in a new field discovery. In each of these three examples, petrophysics was fundamental for proper evaluation of wildcat wells and exploration plays.

Coalson, E.B.; Hartmann, D.J.; Thomas, J.B.

1985-05-01T23:59:59.000Z

332

Air Fluorescence Relevant for Cosmic-Ray Detection - Review of Pioneering Measurements  

E-Print Network [OSTI]

Cosmic rays with energies exceeding $10^{17}$ eV are frequently registered by measurements of the fluorescence light emitted by extensive air showers. The main uncertainty for the absolute energy scale of the measured air showers is coming from the fluorescence light yield of electrons in air. The fluorescence light yield has been studied in laboratory experiments. Pioneering measurements between 1954 and 2000 are reviewed.

Fernando Arqueros; Joerg R. Hoerandel; Bianca Keilhauer

2008-07-24T23:59:59.000Z

333

Microcavity effects on the generation,fluorescence, and diffusion of excitons in organic solar cells  

E-Print Network [OSTI]

We compute the short-circuit diffusion current of excitons in an organic solar cell, with special emphasis on fluorescence losses. The exciton diffusion length is not uniform but varies with its position within the device, even with moderate fluorescence quantum efficiency. With large quantum efficiencies, the rate of fluorescence can be strongly reduced with proper choices of the geometrical and dielectric parameters. In this way, the diffusion length can be increased and the device performance significantly improved.

Kozyreff, G; Vuong, L T; Silleras, O Nieto; Martorell, J

2013-01-01T23:59:59.000Z

334

Typed Self-Optimization  

E-Print Network [OSTI]

type T y[O]. The operator IsIs is self-applicative, in thatargument t is any of Is[O] or IsIs, and otherwise behavesproof constant introduced by IsIs proves that the type of t

Brown, Matt

2013-01-01T23:59:59.000Z

335

AUTOMATED ELEMENTAL ANALYSIS USING ENERGY DISPERSIVE X-RAY FLUORESCENCE ANALYSIS  

E-Print Network [OSTI]

upon the x-ray fluorescence (XRF) method for the elementalnon-destructive nature of XRF is especially important whereconcentrations are measured in the XRF spectrometer and the

Jaklevic, J.M.

2011-01-01T23:59:59.000Z

336

Shelf life of five meat products displayed under light emitting diode or fluorescent lighting.  

E-Print Network [OSTI]

??Light emitting diode (LED) and fluorescent (FLS) lighting effects on enhanced pork loin chops, beef longissimus dorsi and semimembranosus steaks, ground beef, and ground turkey… (more)

Steele, Kyle Stover

2011-01-01T23:59:59.000Z

337

Power control architectures for cold cathode fluorescent lamp and light emitting diode based light sources.  

E-Print Network [OSTI]

?? In this dissertation, two different energy efficient power supply topologies are introduced for controlling cold cathode fluorescent lamp (CCFL) and high-brightness light emitting diode… (more)

Doshi, Montu V.

2010-01-01T23:59:59.000Z

338

E-Print Network 3.0 - amplified fluorescent transduction Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2 PH.9 MICROSYSTEMS TECHNOLOGY LABORATORIES ANNUAL RESEARCH REPORT 2009 PHotonics Heterojunction Photoconductors for chemical Detection Summary: of a fluorescent polymer-chemical...

339

Graphene Signal Amplification for Sensitive and Real-Time Fluorescence Anisotropy Detection of Small Molecules  

E-Print Network [OSTI]

Graphene Signal Amplification for Sensitive and Real-Time Fluorescence Anisotropy Detection graphene oxide (GO) as the signal amplifier. Because of the extraordinarily larger volume of GO

Tan, Weihong

340

E-Print Network 3.0 - atomic fluorescence determination Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

laboratory investigations of the blue-fluorescence spectrum in algal suspensions of Chlorella Source: Oldenburg, Carl von Ossietzky Universitt - Institut fr Physik, Marine...

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

E-Print Network 3.0 - air fluorescence measurements Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

University Collection: Biology and Medicine ; Environmental Sciences and Ecology 77 Sensors and Actuators B 108 (2005) 9931000 Miniaturized fluorescence detection system to...

342

Volume 20. number 3 FEBS LETTERS February 1972 FLUORESCENCE AND DELAYED LIGHT EMISSION IN  

E-Print Network [OSTI]

: dichloroplenol indophenol; DLE: delayed light emission; NADP+: nicotinamide adenine dinucleotide phosphate; PDA (DLE) that of Jursinic and Govindjee [4]. For mea- surements of the recovery of fluorescence transients

Govindjee

343

EA-1881: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts  

Broader source: Energy.gov [DOE]

This EA evaluates the environmental impacts of a proposal to amend energy conservation standards for various consumer products and certain commercial and industrial equipment, including fluorescent lamp ballasts.

344

E-Print Network 3.0 - atomic fluorescence spectrometric Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of Selenium by Fluorescence Spectrometry Summary: MATERIALS 129 5. Ihnat. M.. Atomic absorption spectrometric determination of selenium with carbon furnace... I...

345

Fluorescence-based detection methodologies for nitric oxide using transition metal scaffolds  

E-Print Network [OSTI]

Chapter 1. Fluorescence-Based Detection Methodologies for Nitric Oxide: A Review. Chapter 2. Cobalt Chemistry with Mixed Aminotroponimine Salicylaldimine Ligands: Synthesis, Characterization, and Nitric Oxide Reactivity. ...

Hilderbrand, Scott A. (Scott Alan), 1976-

2004-01-01T23:59:59.000Z

346

Fluorescence spectrum analysis using Fourier series modeling for Fluorescein solution in Ethanol  

E-Print Network [OSTI]

We have measured the fluorescence spectrum for fluorescein solution in ethanol with concentration 1 {\\times} 10-3 mol/liter at different temperatures from room temperature to freezing point of solvent, (T = 153, 183, 223, 253, and 303 K) using liquid nitrogen. Table curve 2D version 5.01 program has been used to determine the fitting curve and fitting equation for each fluorescence spectrum. Fourier series (3 {\\times} 2) was the most suitable fitting equation for all spectra. Theoretical fluorescence spectrum of fluorescein in ethanol at T = 183K was calculated and compared with experimental fluorescence spectrum at the same temperature. There is a good similarity between them.

Hadi, Mahasin F

2011-01-01T23:59:59.000Z

347

High power light emitting diode based setup for photobleaching fluorescent impurities  

E-Print Network [OSTI]

High power light emitting diode based setup for photobleaching fluorescent impurities Tobias K be photobleached before final sample preparation. The instrument consists of high power light emitting diodes

Kaufman, Laura

348

Nuclear Resonance Fluorescence to Measure Plutonium Mass in Spent Nuclear Fuel  

E-Print Network [OSTI]

and Nuclear Recoil . . . . . . . . . . . . . . . . . . . . .2 Quantitative Measurements using NRF 2.1 Nuclear ResonanceFuture Work A Transmission Nuclear Resonance Fluorescence

Ludewigt, Bernhard A

2011-01-01T23:59:59.000Z

349

Capillary electrophoresis-fluorescence line narrowing system (CE-FLNS) for on-line structural characterization  

DOE Patents [OSTI]

Capillary electrophoresis (CE) is interfaced with low temperature fluorescence line-narrowing (FLN) spectroscopy for on-line structural characterization of separated molecular analytes. 21 figs.

Jankowiak, R.J.; Small, G.J.; Shields, P.A.

1999-04-27T23:59:59.000Z

350

Protein- protein interaction detection system using fluorescent protein microdomains  

DOE Patents [OSTI]

The invention provides a protein labeling and interaction detection system based on engineered fragments of fluorescent and chromophoric proteins that require fused interacting polypeptides to drive the association of the fragments, and further are soluble and stable, and do not change the solubility of polypeptides to which they are fused. In one embodiment, a test protein X is fused to a sixteen amino acid fragment of GFP (.beta.-strand 10, amino acids 198-214), engineered to not perturb fusion protein solubility. A second test protein Y is fused to a sixteen amino acid fragment of GFP (.beta.-strand 11, amino acids 215-230), engineered to not perturb fusion protein solubility. When X and Y interact, they bring the GFP strands into proximity, and are detected by complementation with a third GFP fragment consisting of GFP amino acids 1-198 (strands 1-9). When GFP strands 10 and 11 are held together by interaction of protein X and Y, they spontaneous association with GFP strands 1-9, resulting in structural complementation, folding, and concomitant GFP fluorescence.

Waldo, Geoffrey S. (Santa Fe, NM); Cabantous, Stephanie (Los Alamos, NM)

2010-02-23T23:59:59.000Z

351

Red phosphors for use in high CRI fluorescent lamps  

DOE Patents [OSTI]

Novel red emitting phosphors for use in fluorescent lamps resulting in superior color rendering index values compared to conventional red phosphors. Also disclosed is a fluorescent lamp including a phosphor layer comprising blends of one or more of a blue phosphor, a blue-green phosphor, a green phosphor and a red a phosphor selected from the group consisting of SrY.sub.2 O.sub.4 :Eu.sup.3+, (Y,Gd)Al.sub.3 B.sub.4 O.sub.12 :Eu.sup.3+, and [(Y.sub.1-x-y-m La.sub.y)Gd.sub.x ]BO.sub.3 :Eu.sub.m wherein y<0.50 and m=0.001-0.3. The phosphor layer can optionally include an additional deep red phosphor and a yellow emitting phosphor. The resulting lamp will exhibit a white light having a color rendering index of 90 or higher with a correlated color temperature of from 2500 to 10000 Kelvin. The use of the disclosed red phosphors in phosphor blends of lamps results in high CRI light sources with increased stability and acceptable lumen maintenance over the course of the lamp life.

Srivastava, Alok; Comanzo, Holly; Manivannan, Vankatesan; Setlur, Anant Achyut

2005-11-15T23:59:59.000Z

352

Cerenkov emission induced by external beam radiation stimulates molecular fluorescence  

SciTech Connect (OSTI)

Purpose: Cerenkov emission is induced when a charged particle moves faster than the speed of light in a given medium. Both x-ray photons and electrons produce optical Cerenkov photons in everyday radiation therapy of tissue; yet, this phenomenon has never been fully documented. This study quantifies the emissions and also demonstrates that the Cerenkov emission can excite a fluorophore, protoporphyrin IX (PpIX), embedded in biological phantoms. Methods: In this study, Cerenkov emission induced by radiation from a clinical linear accelerator is investigated. Biological mimicking phantoms were irradiated with x-ray photons, with energies of 6 or 18 MV, or electrons at energies 6, 9, 12, 15, or 18 MeV. The Cerenkov emission and the induced molecular fluorescence were detected by a camera or a spectrometer equipped with a fiber optic cable. Results: It is shown that both x-ray photons and electrons, at MeV energies, produce optical Cerenkov photons in tissue mimicking media. Furthermore, we demonstrate that the Cerenkov emission can excite a fluorophore, protoporphyrin IX (PpIX), embedded in biological phantoms. Conclusions: The results here indicate that molecular fluorescence monitoring during external beam radiotherapy is possible.

Axelsson, Johan; Davis, Scott C.; Gladstone, David J.; Pogue, Brian W. [Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755 (United States); Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire 03766 (United States); Thayer School of Engineering and Department of Physics and Astronomy, Dartmouth College, Hanover, New Hampshire 03755 (United States)

2011-07-15T23:59:59.000Z

353

Table of Contents Page i 2013 Residential Compliance Manual January 2014  

E-Print Network [OSTI]

............................................................................24 6.4.2 Incandescent Luminaires

354

Document Type: Subject Terms  

E-Print Network [OSTI]

Title: Authors: Source: Document Type: Subject Terms: Abstract: Full Text Word Count: ISSN at creating team results. In fact, it's priceless. Managers in Western corporations have received a lifetime

Major, Arkady

355

Nucleic acid encoding a self-assembling split-fluorescent protein system  

DOE Patents [OSTI]

The invention provides a protein labeling and detection system based on self-complementing fragments of fluorescent and chromophoric proteins. The system of the invention is exemplified with various combinations of self-complementing fragments derived from Aequorea victoria Green Fluorescent Protein (GFP), which are used to detect and quantify protein solubility in multiple assay formats, both in vitro and in vivo.

Waldo, Geoffrey S. (Santa Fe, NM); Cabantous, Stephanie (Los Alamos, NM)

2011-06-07T23:59:59.000Z

356

Nucleic acid encoding a self-assembling split-fluorescent protein system  

DOE Patents [OSTI]

The invention provides a protein labeling and detection system based on self-complementing fragments of fluorescent and chromophoric proteins. The system of the invention is exemplified with various combinations of self-complementing fragments derived from Aequorea victoria Green Fluorescent Protein (GFP), which are used to detect and quantify protein solubility in multiple assay formats, both in vitro and in vivo.

Waldo, Geoffrey S; Cabantous, Stephanie

2014-04-01T23:59:59.000Z

357

Fluorescence Assay 2. http://www.tgrbio.com/cancer-cell-lines-primary-cell-  

E-Print Network [OSTI]

hazardous waste. Fluorescence microscopy is a powerful tool with a broad scope of applications easily fluorescence microscopy. In creating an innovative protocol for the 5-HT3a receptor, it is necessary-HT3a Expression Purification/Characterization While creating a protocol for protein expression

Collins, Gary S.

358

Improving the photostability of bright monomeric orange and red fluorescent proteins  

E-Print Network [OSTI]

Improving the photostability of bright monomeric orange and red fluorescent proteins Nathan C illumination. Although fluorescent proteins typically bleach at a substantially slower rate than many small-molecule dyes, in many cases the lack of sufficient photostability remains an important limiting factor

Tsien, Roger Y.

359

FLUORESCENCE CHANGES IN PORPHYRIDIUM EXPOSED TO GREEN LIGHT OF DIFFERENT INTENSITY: A NEW EMISSION  

E-Print Network [OSTI]

FLUORESCENCE CHANGES IN PORPHYRIDIUM EXPOSED TO GREEN LIGHT OF DIFFERENT INTENSITY: A NEW EMISSION supposed to require two light reactions for the transfer of one hydrogen atom from water to carbon dioxide the existence of this second trap. With increase in intensity of green light, I,, the differential fluorescence

Govindjee

360

NOVEL Al2O3:C,Mg FLUORESCENT NUCLEAR TRACK DETECTORS FOR PASSIVE NEUTRON DOSIMETRY  

E-Print Network [OSTI]

NOVEL Al2O3:C,Mg FLUORESCENT NUCLEAR TRACK DETECTORS FOR PASSIVE NEUTRON DOSIMETRY G. Jeff Sykora1 in the development of a fluorescent nuclear track detector (FNTD) for neutron and heavy charged particle dosimetry for neutron dosimetry because they have 100% n/g dis- crimination. For instance, CR-39 plastic nuclear track

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Micro-Raman Spectroscopy of Algae: Composition Analysis and Fluorescence Background Behavior  

E-Print Network [OSTI]

ARTICLE Micro-Raman Spectroscopy of Algae: Composition Analysis and Fluorescence Background performed using Stokes Raman scattering for compositional analysis of algae. Two algal species, Chlorella while acquiring Raman signals from the algae. The time dependence of fluorescence background is char

362

Comparison of Pollen Transfer Dynamics by Multiple Floral Visitors: Experiments with Pollen and Fluorescent Dye  

E-Print Network [OSTI]

and Fluorescent Dye LYNN S. ADLER1,2, * and REBECCA E. IRWIN3,4 1 Division of Entomology, Department of Plant, and the utility of fluorescent dye powder as an analogue for pollen transfer was determined. Key Results Xylocopa pollen, even when visiting legitimately. Dye particles were strongly correlated with pollen grains

Irwin, Rebecca E.

363

60.1 / A. Muravsky 60.1: Optical Rewritable Electronic Paper with Fluorescent Dye  

E-Print Network [OSTI]

60.1 / A. Muravsky 60.1: Optical Rewritable Electronic Paper with Fluorescent Dye Doped Liquid-paper by doping LC with fluorescent dye, which absorb blue light & emit in green with high efficiency. 1 was suggested before by every known photoalignment mechanisms, such as: photo-crosslinking [4], azo-dye

364

Far-Red Fluorescent Protein Excitable with Red Lasers for Flow Cytometry and Superresolution STED Nanoscopy  

E-Print Network [OSTI]

Far-Red Fluorescent Protein Excitable with Red Lasers for Flow Cytometry and Superresolution STED Biology, Yale University School of Medicine, New Haven, Connecticut ABSTRACT Far-red fluorescent proteins are required for deep-tissue and whole-animal imaging and multicolor labeling in the red wavelength range

Verkhusha, Vladislav V.

365

Red-emitting fluorescent Organic Light emitting Diodes with low sensitivity to self-quenching  

E-Print Network [OSTI]

Red-emitting fluorescent Organic Light emitting Diodes with low sensitivity to self-quenching S, France *E-mail : sebastien.forget@univ-paris13.fr Keywords: OLED, quenching, doping, red-emitting organic. We herein report on Organic Light-Emitting Diodes (OLEDs) based on a fluorescent amorphous red

Paris-Sud XI, Université de

366

Characterising nutrient-induced fluorescence transients (NIFTs) in nitrogen-stressed Chlorella emersonii (Chlorophyta)  

E-Print Network [OSTI]

Characterising nutrient-induced fluorescence transients (NIFTs) in nitrogen-stressed Chlorella nutrient- induced fluorescence transients (NIFTs) in nitrogen-stressed Chlorella emersonii (Chlorophyta-starvation in batch cultures of the freshwater chlorophyte Chlorella emersonii was followed and the NIFT responses

McCarthy, T.K.

367

A Behavioral SPICE Compatible Model of an Electrodeless Fluorescent Lamp Sam Ben-Yaakov*1  

E-Print Network [OSTI]

to the plasma. In the case of the lamp with electrodes, coupling is via wires. In the case of the electrodelessA Behavioral SPICE Compatible Model of an Electrodeless Fluorescent Lamp Sam Ben-Yaakov*1 , Moshe, SPICE compatible, model was developed for an electrodeless fluorescent lamp (OSRAM SYLVANIA ICETRON

368

Structure-Dependent Fluorescence Efficiencies of Individual Single-Walled Carbon Nanotubes  

E-Print Network [OSTI]

1 Structure-Dependent Fluorescence Efficiencies of Individual Single-Walled Carbon Nanotubes Dmitri, F-33405 France AUTHOR EMAIL ADDRESS: weisman@rice.edu RECEIVED DATE #12;2 ABSTRACT: Single-nanotube fluorimetric intensities. KEYWORDS: SWNT, carbon nanotubes, fluorescence, microscopy, spectroscopy, emission

Boyer, Edmond

369

Matrix-Induced Intensity Fluctuations in the Fluorescence from Single Oligo(phenylenevinylene) Molecules  

E-Print Network [OSTI]

trajectories, spectral shape and position, and fluorescence lifetimes can be used to investigate the chemical and theoretical reports have demonstrated how a fluctuating dielectric nanoenvironment surrounding a polarizable factors on molecular conforma- tion.15,16 In all of these studies, the fluorescent probe molecule is used

Buratto, Steve

370

[16) Green Fluorescent Protein Chimeras to Probe Protein-Protein Interactions  

E-Print Network [OSTI]

[16) Green Fluorescent Protein Chimeras to Probe Protein-Protein Interactions By SANG-HYUN PARK of reproduction in any form reserved. 0076-6879/00 $30.00 #12;252 A B OTHER APPROACHES USING CHIMERAS c ~S65T GFPHDII M 66 .......... 4S,.!;. 31 ui' 14 ..... [lB) FIG. 1. Green fluorescent protein chimera. (A

Raines, Ronald T.

371

Arrays and Cascades of Fluorescent Liquid-Liquid Waveguides: Broadband Light Sources for  

E-Print Network [OSTI]

Arrays and Cascades of Fluorescent Liquid-Liquid Waveguides: Broadband Light Sources) microchannel waveguides with liquid cores containing fluorescent dyes, excited by incident light from an external halogen bulb. Simultaneous use of multiple fluorophores in a common solution, in a single L2 light

Prentiss, Mara

372

Volume 57, number 3 FEBS LETTERS October 1975 INTERACTIONS OF FLUORESCENT ANALOGS OF ADENINE NUCLEOTIDES  

E-Print Network [OSTI]

NUCLEOTIDES WITH COUPLING FACTOR PROTEIN ISOLATED FROM SPINACH CHLOROPLASTS David L. VANDERMEULEN by Farron [ 151, was used in determining its molarity. The fluorescent nucleotides 1,N6ethenoadenosine mono fluorescent nucleotides (mol. wt. G600) bind to the relatively large (mol. wt. = 325 000), slowly rotating CFI

Govindjee

373

Photocleavable fluorescent nucleotides for DNA sequencing on a chip constructed by site-specific  

E-Print Network [OSTI]

Photocleavable fluorescent nucleotides for DNA sequencing on a chip constructed by site sequencing by synthesis using photocleav- able (PC) fluorescent nucleotides [dUTP-PC-4,4-difluoro-4-bora-3 ,4 nucleotides to identify 7 bases in the DNA template. These results demonstrate that the PC nucleotide

Church, George M.

374

FISH and Chips: Automation of Fluorescent Dot Counting in Interphase Cell Nuclei  

E-Print Network [OSTI]

) in each cell nucleus. This system works with two fluorescent dyes, one for the DNA hybridization dotsFISH and Chips: Automation of Fluorescent Dot Counting in Interphase Cell Nuclei Hans Netten,1 Ian abnormalities in inter- phase cell nuclei. This process is called dot counting. To estimate the distribution

van Vliet, Lucas J.

375

Directed evolution methods for improving polypeptide folding and solubility and superfolder fluorescent proteins generated thereby  

DOE Patents [OSTI]

The current invention provides methods of improving folding of polypeptides using a poorly folding domain as a component of a fusion protein comprising the poorly folding domain and a polypeptide of interest to be improved. The invention also provides novel green fluorescent proteins (GFPs) and red fluorescent proteins that have enhanced folding properties.

Waldo, Geoffrey S. (Santa Fe, NM)

2007-09-18T23:59:59.000Z

376

Near-Infrared Fluorescent pH-Sensitive Probes via Unexpected Barbituric Acid  

E-Print Network [OSTI]

Near-Infrared Fluorescent pH-Sensitive Probes via Unexpected Barbituric Acid Mediated Synthesis achilefus@mir.wustl.edu Received October 13, 2008 ABSTRACT Novel near-infrared pyrimidine-fused p by 2D-NMR. All new compounds are highly fluorescent in the near-infrared region and possess excellent

Larson-Prior, Linda

377

Targeting Beta-3 Integrin Using a Linear Hexapeptide Labeled with a Near-Infrared Fluorescent Molecular  

E-Print Network [OSTI]

Targeting Beta-3 Integrin Using a Linear Hexapeptide Labeled with a Near-Infrared Fluorescent-peptides labeled with a near-infrared fluorescent probe (cypate) showed that rearranging the glycine in a linear, and physiopathologic processes mediated by this protein. Keywords: Integrin; cancer; near-infrared; imaging; molecular

Larson-Prior, Linda

378

Classification with Artificial Neural Networks and Support Vector Machines: application to oil fluorescence spectra  

E-Print Network [OSTI]

(WQI), and to signal predictions in a nuclear power plant (Kim WJ, S H Chang & B H Lee 1993). They haveClassification with Artificial Neural Networks and Support Vector Machines: application to oil, and Oil fluorescence ABSTRACT: This paper reports on oil classification with fluorescence spectroscopy

Oldenburg, Carl von Ossietzky Universität

379

Performance dependence of hybrid x-ray computed tomography/fluorescence molecular  

E-Print Network [OSTI]

Performance dependence of hybrid x-ray computed tomography/fluorescence molecular tomography imaging systems combining x-ray computed tomography (CT) and fluorescence tomography can im- prove Ntziachristos2 1 Department of Electrical and Computer Engineering, Northeastern University, 360 Huntington Ave

Miller, Eric

380

Optical fiber-based fluorescent viscosity sensor Mark A. Haidekker and Walter J. Akers  

E-Print Network [OSTI]

Optical fiber-based fluorescent viscosity sensor Mark A. Haidekker and Walter J. Akers Department bound to a fiber-optic tip without loss of viscosity sensi- tivity. The optical fiber itself may be used to molecular rotors in solution. An optical fiber-based fluorescent vis- cosity sensor may be used in real

Theodorakis, Emmanuel

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Demonstration of Fluorescent RGB Electrowetting Devices for Light Wave Coupling Displays  

E-Print Network [OSTI]

and wasted, instead of recycling the light for use at pixels in the ON state. We present the demonstration-degrade the organic fluorescent oils. Violet light sources include custom developed cold-cathode- fluorescent lamps of a traditional diffuse backlight because (as will be discussed later) it allows for the advantage of recycling

Steckl, Andrew J.

382

X-ray Fluorescence Measurements of Manganese in Petroglyphs and Graffiti in the Bluff, Utah Area  

E-Print Network [OSTI]

X-ray Fluorescence Measurements of Manganese in Petroglyphs and Graffiti in the Bluff, Utah Area the age of rock art using Mn levels, Lytle (2008). In this work we use x-ray fluorescence (XRF) to measure of methods including atomic mass spectroscopy (AMS) measurements of 14 C, Particle-induced X-ray Excitation

383

Fluorescent Functionalized Mesoporous Silica for Radioactive Material Extraction  

SciTech Connect (OSTI)

Mesoporous silica with covalently bound salicylic acid molecules incorporated in the structure was synthesized with a one-pot, co-condensation reaction at room temperature. The as-synthesized material has a large surface area, uniform particle size, and an ordered pore structure as determined by characterization with transmission electron microscopy, thermal gravimetric analysis, and infrared spectra, etc. Using the strong fluorescence and metal coordination capability of salicylic acid, functionalized mesoporous silica (FMS) was developed to track and extract radionuclide contaminants, such as uranyl [U(VI)] ions encountered in subsurface environments. Adsorption measurements showed a strong affinity of the FMS toward U(VI) with a Kd value of 105 mL/g, which is four orders of magnitude higher than the adsorption of U(VI) onto most of the sediments in natural environments. The new materials have a potential for synergistic environmental monitoring and remediation of the radionuclide U(VI) from contaminated subsurface environments.

Li, Juan; Zhu, Kake; Shang, Jianying; Wang, Donghai; Nie, Zimin; Guo, Ruisong; Liu, Chongxuan; Wang, Zheming; Li, Xiaolin; Liu, Jun

2012-08-01T23:59:59.000Z

384

Electronic starter device for fluorescent lamps. Final report  

SciTech Connect (OSTI)

Due to silicon supplier failures to produce the 03/04 triac silicon as specified in the original proposal, the direction of the starter program was migrated to use available off the shelf power semiconductors. This had unexpected positive side effects including a reduction in component price, improved quality, and the refocus of engineering efforts to concentrate on the Super ASIC core technology. The starter program has begun shipments employing this new architecture, and is being well received both in the US and abroad. In its present form, the starter meets original cost projections within 20%. Work is continuing on the 0.8 micron ASIC, which will allow for the starter to sell below $1.00 in volume. Even at the slightly higher price, interest is strong in replacing the low performance glow starter for small fluorescent applications with a high performance alternative.

NONE

1998-06-01T23:59:59.000Z

385

Conjugated polymer fluorescence: Interplay of correlations and alternation  

SciTech Connect (OSTI)

Conjugated polymers can have high conductivity on doping, large nonlinear optical response in semiconducting state, and be used as LEDs. These polymers include polyactylene, polydiacetylenes, polysilanes, polythiophene, poly-p-phenylenevinylene. Polymer fluorescence is related to the lowest singlet excited state S{sub 1}. Polymer and oligomer data are shown for the excitation energy ratio of the two-photon and one-photon gaps. There is a ratio crossover with increasing e-e correlations in any centrosymmetri chain with an insulating ground state. The {pi}-conjugated polymers present various band gaps at constant correlations, and single-particle gaps can be related to the structure. The nature of the lowest singlet excited state depends sensitively on both correlations and alternation. 22 refs, 2 figs.

Soos, Z.G. [Princeton Univ., NJ (United States). Dept. of Chemistry; Galvao, D.S. [Bell Communications Research, Inc., Red Bank, NJ (United States)]|[Universidade Estadual de Campinas, SP (Brazil). Dept. de Fisica Aplicada; Etemad, S. [Bell Communications Research, Inc., Red Bank, NJ (United States); Kepler, R.G. [Sandia National Labs., Albuquerque, NM (United States)

1993-12-31T23:59:59.000Z

386

Algorithms for Fluorescence Lifetime Microscopy and Optical Coherence Tomography Data Analysis: Applications for Diagnosis of Atherosclerosis and Oral Cancer  

E-Print Network [OSTI]

imaging (FLIM) with optical coherence tomography (OCT), for the diagnosis of atherosclerosis and oral cancer. FLIM is a fluorescence imaging technique that is capable of providing information about auto fluorescent tissue biomolecules. OCT on the other...

Pande, Paritosh

2014-05-16T23:59:59.000Z

387

Application of a ratiometric laser induced fluorescence (LIF) thermometry for micro-scale temperature measurement for natural convection flows  

E-Print Network [OSTI]

A ratiometric laser induced fluorescence (LIF) thermometry applied to micro-scale temperature measurement for natural convection flows. To eliminate incident light non-uniformity and imperfection of recording device, two fluorescence dyes are used...

Lee, Heon Ju

2004-11-15T23:59:59.000Z

388

Cavity induced modifications to the resonance fluorescence and probe absorption of a laser-dressed V atom  

E-Print Network [OSTI]

A cavity-modified master equation is derived for a coherently driven, V-type three-level atom coupled to a single-mode cavity in the bad cavity limit. We show that population inversion in both the bare and dressed-state bases may be achieved, originating from the enhancement of the atom-cavity interaction when the cavity is resonant with an atomic dressed-state transition. The atomic populations in the dressed state representation are analysed in terms of the cavity-modified transition rates. The atomic fluorescence spectrum and probe absorption spectrum also investigated, and it is found that the spectral profiles may be controlled by adjusting the cavity frequency. Peak suppression and line narrowing occur under appropriate conditions.

Jin-Sheng Peng; Gao-Xiang Li; Peng Zhou; S. Swain

2000-03-20T23:59:59.000Z

389

High-Efficiency White Organic Light-Emitting Devices Based on a Highly Amorphous Iridium(III) Orange Phosphor  

E-Print Network [OSTI]

- didates as future illumination sources over the conventional incandescent bulbs and fluorescent lamps of the electroluminescence spectrum is observed, with the blue color intensity increasing relative to the orange component been prepared using this stacked concept with both fluorescent12,13 and phosphorescent emitters.14

390

Confocal microphotoluminescence of InGaN-based light-emitting diodes Koichi Okamoto,a  

E-Print Network [OSTI]

for conventional incandescent and fluorescent light bulbs.5 However, luminous efficacies of commercial white LEDs spectrum region, the external quantum efficiency ext of the LED has achieved 20% at room temperature 25 lm/W have been still lower than that of fluorescent tubes 75 lm/W . Thus, the most important re

Okamoto, Koichi

391

theropod dinosaurs. The absence of respiratory turbinates in  

E-Print Network [OSTI]

incandescent bulb (350 to 400 nm)], the dark blue­indigo fluorescence of the liver in Scipionyx is distinct. With, Bile Pigments (Academic Press, New York, 1968)]. Fluorescence of biliverdin includes a primary light emission peak at about 470 nm, which corresponds to the blue region of the spectrum of visible

392

Cyanine-based probe\\tag-peptide pair for fluorescence protein imaging and fluorescence protein imaging methods  

DOE Patents [OSTI]

A molecular probe comprises two arsenic atoms and at least one cyanine based moiety. A method of producing a molecular probe includes providing a molecule having a first formula, treating the molecule with HgOAc, and subsequently transmetallizing with AsCl.sub.3. The As is liganded to ethanedithiol to produce a probe having a second formula. A method of labeling a peptide includes providing a peptide comprising a tag sequence and contacting the peptide with a biarsenical molecular probe. A complex is formed comprising the tag sequence and the molecular probe. A method of studying a peptide includes providing a mixture containing a peptide comprising a peptide tag sequence, adding a biarsenical probe to the mixture, and monitoring the fluorescence of the mixture.

Mayer-Cumblidge, M. Uljana (Richland, WA); Cao, Haishi (Richland, WA)

2010-08-17T23:59:59.000Z

393

Comment on ``Resonance-fluorescence and absorption spectra of a two-level atom driven by a strong bichromatic field''  

E-Print Network [OSTI]

Comment on ``Resonance-fluorescence and absorption spectra of a two-level atom driven by a strong predictions of the resonance fluorescence from a two-level atom driven by a strong bichromatic field J. Opt.50.Hz, 33.50.Dq, 32.80. t In studying the resonance fluorescence from a driven two- level atom, we

Boyd, Robert W.

394

The effect of a synthetic cytokinin, 6-benzylaminopurine, and light quality on Ficus benjamina under low light intensities  

E-Print Network [OSTI]

of artificial light sources, the effects of the different wavelengths have become more important, as artificial light sources do not emi t as wide a spectrum as does natural sunlight. Cool white fluorescent tubes have a high blue licht component, while i... higher dry weight gain than fluorescent plus tungsten plus mercury or fluorescent plus mercury, or fluor scent alone (23). Incandescent bulbs are high in infrared irradiation compared to fluorescent light sources, and it has been found that infrared 1r...

Meadows, Sylvia Elise

1979-01-01T23:59:59.000Z

395

Improved model for the analysis of air fluorescence induced by electrons  

E-Print Network [OSTI]

A model recently proposed for the calculation of air-fluorescence yield excited by electrons is revisited. Improved energy distributions of secondary electrons and a more realistic Monte Carlo simulation including some additional processes have allowed us to obtain more accurate results. The model is used to study in detail the relationship between fluorescence intensity and deposited energy in a wide range of primary energy (keVs - GeVs). In addition, predictions on the absolute value of the fluorescence efficiency in the absence of collisional quenching will be presented and compared with available experimental data.

F. Arqueros; F. Blanco; J. Rosado

2008-07-24T23:59:59.000Z

396

On-site demonstration procedure for solid-state fluorescent ballast  

SciTech Connect (OSTI)

The report was presented to plant engineers and managers who were involved in an on-site demonstration of EETech solid-state ballasts for two 40-watt T12 fluorescent lamps. The report includes a brief review of the operating principles of solid-state fluorescent ballasts and the status of development achieved during the LBL program. The remainder of the test describes the techniques of managing and instrumenting a test area for assessing the performance of solid-state fluorescent ballasts at an occupied site.

Verderber, R.; Morse, O.

1980-09-01T23:59:59.000Z

397

Dust around Type Ia supernovae  

E-Print Network [OSTI]

Dust around Type Ia supernovae Lifan Wang 1,2 LawrenceIa. Subject headings: Supernovae: General, Dust, Extinctionline) bands for Type Ia supernovae. (a), upper panel, shows

Wang, Lifan

2005-01-01T23:59:59.000Z

398

Wolter type i LAMAR  

SciTech Connect (OSTI)

Observational objectives for the LAMAR and their influence on the instrument design are discussed. It is concluded that the most important design parameter is the angular resolution of the LAMAR modules since it so strongly influences sensitivity, optical identifications, source confusion, spectral resolution for objective gratings and the ability to resolve small extended sources. A high resolution Wolter Type I LAMAR module is described, its hardware status discussed, and the performance of a LAMAR observatory presented. A promising technique for enhancing the reflectivity of Wolter Type I X-ray optics in a selected bandpass at high energy has been investigated and the performance of the LAMAR module, utilizing this method, has been calculated.

Catura, R.C.; Joki, E.G.

1981-11-01T23:59:59.000Z

399

Definitions: Types of Commissioning  

E-Print Network [OSTI]

Workshop on the Continuous Commissioning® Process Joseph T. Martinez, PCC Carlos Yagua, PE Hiroko Masuda, Juan-Carlos Baltazar, PhD, PE Ahmet Ugursal, PhD Clean Air Through Energy Efficiency (CATEE) Conference, Dallas, Texas. November 18, 2014... 5. Continuous Commissioning Measures 6. Measurement and Verification ESL-KT-14-11-41 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 Definitions: Types of Commissioning Joseph T. Martinez, PCC Carlos Yagua, PE Hiroko...

Martinez, J. T.

2014-01-01T23:59:59.000Z

400

Airborne laser induced fluorescence imaging. Innovative technology summary report  

SciTech Connect (OSTI)

Laser-Induced Fluorescence (LIF) was demonstration as part of the Fernald Environmental Management Project (FEMP) Plant 1 Large Scale Demonstration and Deployment Project (LSDDP) sponsored by the US Department of Energy (DOE) Office of Science and Technology, Deactivation and Decommissioning Focus Area located at the Federal Energy Technology Center (FETC) in Morgantown, West Virginia. The demonstration took place on November 19, 1996. In order to allow the contaminated buildings undergoing deactivation and decommissioning (D and D) to be opened to the atmosphere, radiological surveys of floors, walls and ceilings must take place. After successful completion of the radiological clearance survey, demolition of the building can continue. Currently, this process is performed by collecting and analyzing swipe samples for radiological analysis. Two methods are used to analyze the swipe samples: hand-held frisker and laboratory analysis. For the purpose of this demonstration, the least expensive method, swipe samples analyzed by hand-held frisker, is the baseline technology. The objective of the technology demonstration was to determine if the baseline technology could be replaced using LIF.

NONE

1999-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Diagnostic Implications of the Reactivity of Fluorescence Tracers  

SciTech Connect (OSTI)

Measurements of fuel concentration distributions with planar laser induced fluorescence of tracer molecules that are added to a base fuel are commonly used in combustion research and development. It usually is assumed that the tracer concentration follows the parent fuel concentration if physical properties such as those determining evaporation are matched. As an example to address this general issue a computational study of combustion of biacetyl/iso-octane mixtures was performed to investigate how well the concentration of biacetyl represents the concentration of iso-octane. For premixed mixture conditions with flame propagation the spatial concentration profiles of the two species in the flame front are separated by 110 {micro}m at 1 bar and by 11 {micro}m at 10 bar. For practical applications this spatial separation is insignificantly small. However, for conditions that mimic ignition and combustion in diesel and HCCI-like operation the differences in tracer and fuel concentration can be significant, exceeding hundreds of percent. At low initial temperature biacetyl was found to be more stable whereas at higher temperature (>1000K) iso-octane is more stable. Similar findings were obtained for a multi-component fuel comprised of iso-octane, n-heptane, methylcyclohexane, and toluene. It may be assumed that similar differences can exist for other tracer/fuel combinations. Caution has therefore to be applied when interpreting PLIF measurements in homogeneous reaction conditions such as in HCCI engine studies.

Sick, V; Westbrook, C

2008-07-14T23:59:59.000Z

402

Fluorescence from a quantum dot and metallic nanosphere hybrid system  

SciTech Connect (OSTI)

We present energy absorption and interference in a quantum dot-metallic nanosphere system embedded on a dielectric substrate. A control field is applied to induce dipole moments in the nanosphere and the quantum dot, and a probe field is applied to monitor absorption. Dipole moments in the quantum dot or the metal nanosphere are induced, both by the external fields and by each other's dipole fields. Thus, in addition to direct polarization, the metal nanosphere and the quantum dot will sense one another via the dipole-dipole interaction. The density matrix method was used to show that the absorption spectrum can be split from one peak to two peaks by the control field, and this can also be done by placing the metal sphere close to the quantum dot. When the two are extremely close together, a self-interaction in the quantum dot produces an asymmetry in the absorption peaks. In addition, the fluorescence efficiency can be quenched by the addition of a metal nanosphere. This hybrid system could be used to create ultra-fast switching and sensing nanodevices.

Schindel, Daniel G. [Department of Mathematics and Statistics, University of Winnipeg, 515 Portage Avenue, Winnipeg, MB, R3B 2E9 (Canada); Singh, Mahi R. [Department of Physics and Astronomy, University of Western Ontario, 1151 Richmond Street, London, ON, N6A 3K7 (Canada)

2014-03-31T23:59:59.000Z

403

Comprehensive Pyrometry of Incandescent Multiwalled Carbon Nanotubes and Graphene in the Visible and Near Infrared  

E-Print Network [OSTI]

E. Pop, “Infrared Microscopy of Joule Heating in Graphenenear infrared is attainable through gating and heating of

Singer, Scott

2012-01-01T23:59:59.000Z

404

A calibration-independent laser-induced incandescence technique for soot measurement  

E-Print Network [OSTI]

@nrc.ca), and F. Liu (fèngshan.liu@nrc.ca) are with The Institute for Chemical Process and Environmental levels of particulate matter exacerbates several pulmonary diseases, including asthma, bronchitis is a serious environmental pollutant and a health risk. To assist policy markers in regulating particulate

Gülder, �mer L.

405

Aerosol Mass Spectrometry via Laser-Induced Incandescence Particle Vaporization Final Report  

SciTech Connect (OSTI)

We have successfully developed and commercialized a soot particle aerosol mass spectrometer (SP-AMS) instrument to measure mass, size, and chemical information of soot particles in ambient environments. The SP-AMS instrument has been calibrated and extensively tested in the laboratory and during initial field studies. The first instrument paper describing the SP-AMS has been submitted for publication in a peer reviewed journal and there are several related papers covering initial field studies and laboratory studies that are in preparation. We have currently sold 5 SP-AMS instruments (either as complete systems or as SP modules to existing AMS instrument operators).

Timothy B. Onasch

2011-10-20T23:59:59.000Z

406

Comprehensive Pyrometry of Incandescent Multiwalled Carbon Nanotubes and Graphene in the Visible and Near Infrared  

E-Print Network [OSTI]

of 1990 (ITS-90). ,” Metrologia, vol. 27, p. 3, Mar. 1990. [Wavelength Pyrometry,” Metrologia, vol. 17, p. 103, 1981. [

Singer, Scott

2012-01-01T23:59:59.000Z

407

Fluorescence of curium(III) in solutions of isopoly- and heteropolytungstates  

SciTech Connect (OSTI)

The authors describe the fluorescence of polytungstate complexes of curium (the term polytungstate complexes connotes both curium decatungstate and curium complexes with heteropolytungstate anions). The emitter is the curium(III) ion, which is excited as a result of energy transfer with the ligand. The data obtained permit a supplementation of the picture of the mutual interaction of the spectral and chemical properties of the f-elements with their ability to fluoresce in polytungstate complexes (there is only individual information on this question, pertaining only to the fluorescence of the lanthanides, chiefly Eu, Tb, Sm, and Dy). The fluorescence of curium(III) has also been used as a method of studying its complex formation with heteropolytungstate anions.

Yusov, A.B.; Fedoseev, A.M.; Spitsyn, V.I.; Krot, N.N.

1986-11-01T23:59:59.000Z

408

Non-invasive detection of oral cancer using reflectance and fluorescence spectroscopy  

E-Print Network [OSTI]

In vivo reflectance and fluorescence spectra were collected from patients with oral lesions, as well as healthy volunteers, in order to evaluate the potential of spectroscopy to serve as a non-invasive tool for the detection ...

McGee, Sasha Alanda

2008-01-01T23:59:59.000Z

409

Turn-on fluorescent probes for detecting nitric oxide in biology  

E-Print Network [OSTI]

Chapter 1. Investigating the Biological Roles of Nitric Oxide and Other Reactive Nitrogen Species Using Fluorescent Probes: This chapter presents an overview of recent progress in the field of reactive nitrogen species ...

McQuade, Lindsey Elizabeth, 1981-

2010-01-01T23:59:59.000Z

410

Measurement and model assessment of fluorescence lifetime sensing in multiply scattering media  

E-Print Network [OSTI]

fluorescent dyes, 3,3-diethylthiatricarbocyanine iodide (DTTCI) and Indocynanine Green (ICG), which exhibit distinctly different lifetimes and each exhibits single-exponential decay kinetics, were employed. Measurements of phase-modulation as a function...

Kuwana, Eddy

2005-08-29T23:59:59.000Z

411

Development of a radiative transport based, fluorescence-enhanced, frequency-domain small animal imaging system  

E-Print Network [OSTI]

% intralipid solutions. Through collaboration with Transpire, Inc., a fluorescence-enhanced, frequency-domain, radiative transport equation (RTE) solver was developed. This solver incorporates the discrete ordinates, source iteration with diffusion synthetic...

Rasmussen, John C.

2009-05-15T23:59:59.000Z

412

Metal-based turn-on fluorescent probes for nitric oxide sensing  

E-Print Network [OSTI]

Chapter 1. Metal-Based Turn-On Fluorescent Probes for Sensing Nitric Oxide. Nitric oxide, a reactive free radical, regulates a variety of biological processes. The absence of tools to detect NO directly, rapidly, specifically ...

Lim, Mi Hee

2006-01-01T23:59:59.000Z

413

Synthesis and Characterization of Novel Fluorescent Injectable Micro-Carriers for Tissue Regeneration  

E-Print Network [OSTI]

Specific problem: Our previous study showed that the nanofibrous poly-l-lactic acid (NF-PLLA) microspheres are excellent cell carriers for tissue regeneration. However, these injectable microspheres are not fluorescent biomaterials. Incorporation...

Arora, Akshi

2014-04-28T23:59:59.000Z

414

An improved understanding of fluorescent Zn(II) sensors and their uses in biological settings  

E-Print Network [OSTI]

Chapter 1. An Introduction to Fluorescent Zn(II) Sensors and Their Applications in Biological Systems This chapter opens with an overview of the numerous roles of zinc in biology, with an emphasis on labile Zn(II), that ...

Wong, Brian Alexander

2009-01-01T23:59:59.000Z

415

In vivo biosensing via tissue-localizable near-infrared-fluorescent single-walled carbon nanotubes  

E-Print Network [OSTI]

Single-walled carbon nanotubes are particularly attractive for biomedical applications, because they exhibit a fluorescent signal in a spectral region where there is minimal interference from biological media. Although ...

Iverson, Nicole M.

416

Real-Time Measurements of Actin Filament Polymerization by Total Internal Reflection Fluorescence Microscopy  

E-Print Network [OSTI]

Real-Time Measurements of Actin Filament Polymerization by Total Internal Reflection Fluorescence polymerization and its regulation by associated proteins requires an assay to monitor polymerization dynamics nucleotide. INTRODUCTION Actin polymerization contributes to many cellular processes under the control

417

Computational image analysis of subcellular dynamics in time-lapse fluorescence microscopy  

E-Print Network [OSTI]

The use of image segmentation and motion tracking algorithms was adapted for analyzing time-lapse data of cells with fluorescently labeled protein. Performance metrics were devised and algorithm parameters were matched to ...

Huang, Austin V., 1980-

2005-01-01T23:59:59.000Z

418

Computational Prediction of Absorbance Maxima for a Structurally Diverse Series of Engineered Green Fluorescent Protein Chromophores  

E-Print Network [OSTI]

Fluorescent Protein Chromophores Qadir K. Timerghazin, Haley J. Carlson, Chen Liang, Robert E. Campbell,* and Alex Brown* UniVersity of Alberta, Department of Chemistry, Edmonton, Alberta T6G 2G2, Canada Recei

Campbell, Robert E.

419

A parallel adaptive finite element simplified spherical harmonics approximation solver for frequency domain fluorescence molecular imaging  

E-Print Network [OSTI]

fluorescence molecular imaging Yujie Lu1 , Banghe Zhu1 , Haiou Shen2 , John C Rasmussen1 , Ge Wang2 and Eva M of the domain at excitation and emission wavelengths xf a absorption coefficient of the fluorophore cb light

Virginia Tech

420

E-Print Network 3.0 - anomalous negative fluorescence Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

5 Effect of pH on Aqueous Phenylalanine Studied Using a 265-nm Pulsed Light-emitting Diode Summary: , and approximately 12-nm bandwidth. The LED enables the fluorescence...

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

E-Print Network 3.0 - anomalous x-ray fluorescence Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

in the emission of a fluorescent X-ray. As a rule of thumb 15... Optimization of X-ray energy resolution from a horizontally focused ... Source: Hendrickson, Wayne A. -...

422

Supervised Machine Learning Algorithms for Early Detection of Oral Epithelial Cancer Using Fluorescence Lifetime Imaging Microscopy  

E-Print Network [OSTI]

In this study, the clinical potential of the endogenous multispectral Fluorescence lifetime imaging microscopy (FLIM) was investigated to objectively detect oral cancer. To this end, in vivo FLIM imaging was performed on a hamster cheek pouch model...

Lee, Joohyung

2014-08-06T23:59:59.000Z

423

Optimization of Two-photon Excited Fluorescence Enhancement between Tunable and Broadband Femtosecond Laser Pulse Excitations  

E-Print Network [OSTI]

-beam expanding and focusing, and compound-lens for efficient fluorescence collection with good spectral resolution, ensures accurate TPEF measurements. Differentiated TPEF enhancements of Indo-1 (1.6), FITC (6.7), and TRITC (5.2) proportionally agree...

Wang, Chao

2012-02-14T23:59:59.000Z

424

The Application of Fluorescence Lifetime Imaging Microscopy to Quantitatively Map Mixing and Temperature in Microfluidic Systems   

E-Print Network [OSTI]

The technique of Fluorescence Lifetime Imaging Microscopy (FLIM) has been employed to quantitatively and spatially map the fluid composition and temperature within microfluidic systems. A molecular probe with a ...

Graham, Emmelyn M

2008-01-01T23:59:59.000Z

425

Mechanism of the efficient quenching of tryptophan fluorescence in human gamma crystallin  

E-Print Network [OSTI]

Quenching of the fluorescence of buried tryptophans (Trps) is an important reporter of protein conformation. Human [gamma]D-crystallin (H[gamma]D-Crys) and human [gamma]S-crystallin (H[gamma]S-Crys) are both very stable ...

Chen, Jiejin, Ph. D. Massachusetts Institute of Technology

2008-01-01T23:59:59.000Z

426

Fluorescent Dye Encapsulated ZnO Particles with Cell-specific...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Dye Encapsulated ZnO Particles with Cell-specific Toxicity for Potential use in Biomedical Applications. Fluorescent Dye Encapsulated ZnO Particles with Cell-specific Toxicity...

427

Forecast Technical Document Forecast Types  

E-Print Network [OSTI]

Forecast Technical Document Forecast Types A document describing how different forecast types are implemented in the 2011 Production Forecast system. Tom Jenkins Robert Matthews Ewan Mackie Lesley Halsall #12;PF2011 ­ Forecast Types Background Different `types' of forecast are possible for a specified area

428

Laser induced coal fluorescence. Ninth quarterly technical progress report, October 1-December 31, 1984. [Alginite  

SciTech Connect (OSTI)

The work during this reporting period has included a systematic fluorescence analysis of thirteen New Albany Shale samples of the Illinois basin. Fluorescence spectra obtained by continuous wave (c-w) excitation of 45 alginite macerals were collected for each shale sample. This work is now being continued by collecting the time-resolved data, and preliminary results are reported here. Additional software has been written to simplify the acquisition and manipulation of the time-resolved data. 9 figures, 4 tables.

Borst, W.L.

1984-01-01T23:59:59.000Z

429

BIOCHIMICA ET BIOPHYSICA ACTA 371 FLUORESCENCE SPECTRA OF CHLORELLA IN THE 295-77K RANGE*  

E-Print Network [OSTI]

BIOCHIMICA ET BIOPHYSICA ACTA 371 BBA45950 FLUORESCENCE SPECTRA OF CHLORELLA IN THE 295-77°K RANGE A relation of fluorescence spectra of Chlorella (in the 295-77°K range) to the changes in the phase in the 77-295°K range, is composed of several bands (F7I7 and F725). If Chlorella cells are first cooled

Govindjee

430

Organic light-emitting device with a phosphor-sensitized fluorescent emission layer  

DOE Patents [OSTI]

The present invention relates to organic light emitting devices (OLEDs), and more specifically to OLEDS that emit light using a combination of fluorescent emitters and phosphorescent emitters. The emissive region of the devices of the present invention comprise at least one phosphor-sensitized layer which has a combined emission from a phosphorescent emitter and a fluorescent emitter. In preferred embodiments, the invention relates to white-emitting OLEDS (WOLEDs).

Forrest, Stephen (Ann Arbor, MI); Kanno, Hiroshi (Osaka, JP)

2009-08-25T23:59:59.000Z

431

On-line measurement of lignin in wood pulp by color shift of fluorescence  

DOE Patents [OSTI]

Lignin concentrations from wood pulp samples are measured by applying an excitation light at a selected wavelength to the samples in order to cause the lignin to emit fluorescence. A spectral distribution of the fluorescence emission is then determined. The lignin concentration is then calculated based on the spectral distribution signal. The spectral distribution is quantified by either a wavelength centroid method or a band ratio method. 6 figs.

Jeffers, L.A.; Malito, M.L.

1996-01-23T23:59:59.000Z

432

On-line measurement of lignin in wood pulp by color shift of fluorescence  

DOE Patents [OSTI]

Lignin concentrations from wood pulp samples are measured by applying an excitation light at a selected wavelength to the samples in order to cause the lignin to emit fluorescence. A spectral distribution of the fluorescence emission is then determined. The lignin concentration is then calculated based on the spectral distribution signal. The spectral distribution is quantified by either a wavelength centroid method or a band ratio method.

Jeffers, Larry A. (Washington Township, Stark County, OH); Malito, Michael L. (Liberty Township, Trumbull County, OH)

1996-01-01T23:59:59.000Z

433

Automation of the Laguerre Expansion Technique for Analysis of Time-resolved Fluorescence Spectroscopy Data  

E-Print Network [OSTI]

AUTOMATION OF THE LAGUERRE EXPANSION TECHNIQUE FOR ANALYSIS OF TIME-RESOLVED FLUORESCENCE SPECTROSCOPY DATA A Thesis by ADITI SANDEEP DABIR Submitted to the Office of Graduate Studies of Texas A&M University in partial... fulfillment of the requirements for the degree of MASTER OF SCIENCE December 2009 Major Subject: Biomedical Engineering AUTOMATION OF THE LAGUERRE EXPANSION TECHNIQUE FOR ANALYSIS OF TIME-RESOLVED FLUORESCENCE SPECTROSCOPY DATA A Thesis...

Dabir, Aditi Sandeep

2010-07-14T23:59:59.000Z

434

Flow method and apparatus for screening chemicals using micro x-ray fluorescence  

DOE Patents [OSTI]

Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.

Warner, Benjamin P. (Los Alamos, NM); Havrilla, George J. (Los Alamos, NM); Miller, Thomasin C. (Bartlesville, OK); Lewis, Cris (Los Alamos, NM); Mahan, Cynthia A. (Los Alamos, NM); Wells, Cyndi A. (Los Alamos, NM)

2011-04-26T23:59:59.000Z

435

Flow method and apparatus for screening chemicals using micro x-ray fluorescence  

DOE Patents [OSTI]

Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow-separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.

Warner, Benjamin P. (Los Alamos, NM); Havrilla, George J. (Los Alamos, NM); Miller, Thomasin C. (Bartlesville, OK); Lewis, Cris (Los Alamos, NM); Mahan, Cynthia A. (Los Alamos, NM); Wells, Cyndi A. (Los Alamos, NM)

2009-04-14T23:59:59.000Z

436

N,N,NV,NV-tetramethyl-p-phenylenediamine initiates the appearance of a well-resolved I peak in the kinetics of chlorophyll fluorescence rise  

E-Print Network [OSTI]

fluorescence; Fm (=P)maximum level of chlorophyll fluorescence; Fv (=FmÃ?Fo), variable fluorescence; OEC, oxygen-evolving tissues, the initial fluorescence measured with all reaction centers in open state, Fo (O), rises to a peak level, Fm ( = P), observed when all reaction centers are closed, with two intermediate steps J (I1

Carpentier, Robert

437

Stardust Interstellar Preliminary Examination VI: Quantitative elemental analysis by synchrotron X-ray fluorescence nanoimaging of eight impact features in aerogel  

E-Print Network [OSTI]

-ray fluorescence nanoimaging of eight impact features in aerogel Alexandre S. SIMIONOVICI1* , Laurence LEMELLE2

Nittler, Larry R.

438

Application Of LIF Technique In The Diagnosis Of Some Human Cancer Types  

SciTech Connect (OSTI)

Fluorescence spectroscopy is an evolving technology that can rapidly differentiate between benign and malignant tissues. These differences are thought to be due to endogenous fluorophores, including nicotinamide adenine dinucleotide, flavin adenine dinucleotide, and tryptophan, and absorbers such as {beta}-carotene and hemoglobin. This is a non-invasive diagnostic tool that can identify diseased tissue sites in situ and in real time could have a major impact on the detection and treatment of cancer. This study evaluates the utility of autofluorescence and spectroscopy to distinguish tissue transformation associated with the malignant change in two types of human cancer - colorectal and breast cancer - Fluorescence spectra were obtained using a high-sensitivity fiber optic spectrometer and using two types of excitation sources, Argon laser with an emission at wavelength 488 nm and Xenon lamp. The results showed that the fluorescence intensity changes from normal to malignant tissue samples may be explained in terms of simple collagen, oxidized riboflavins and NAD(P)H intensity changes. In the future, improving our understanding of the biological changes that can be assessed using spectroscopy will not only improve optical techniques but also provide new tools to better understand cancer biology.

El-Hussein, A.; Kasem, A. K.; Harith, M. A. [National Institute of Laser Enhanced Science, Cairo University (Egypt); Ismail, H. [National Cancer Institute, Cairo University (Egypt)

2009-09-27T23:59:59.000Z

439

Conservation potential of compact fluorescent lamps in India and Brazil  

SciTech Connect (OSTI)

We evaluate the conservation potential of compact fluorescent lamps (CFLs) for managing the rapidly increasing electrical energy and peak demand in India and Brazil. Using very conservative assumptions, we find that the cost of conserved energy using 16 W CFLs is 4 and 6 times less than the long range marginal cost of electricity for the two countries. The cost of avoided peak installed capacity is 6 and 9.5 times less than the cost of new installed capacity for India and Brazil. The analysis is undertaken from the three separate perspectives of the national economies, the consumers, and the utilities. We find that because residential electricity is subsidized, the consumers have little or no incentive to purchase and install the CFLs, unless they too are subsidized. However, the benefits of CFL installation to the utility are so large that subsidizing them is a paying proposition for the utility are so large that subsidizing them is a paying proposition for the utility in almost all cases. As an illustration of a gradual introduction strategy for CFLs, we calculate a scenario where national savings of the order of US $1.2 million per day for India and US $2.5 million per day for Brazil are reached in 10 years by a small and gradual transfer of subsidy from residential electricity to CFLs. We then explore the barriers to immediate large scale introduction of these lamps in the two countries. Specific technical and marketing problems are identified and discussed, which would require solution before such an introduction can be attempted. Lastly, we discuss the range of policy instruments, in addition to a subsidy scheme, that can be used for promoting the diffusion of these lamps in the domestic and commercial sector. 47 refs., 15 figs., 2 tabs.

Gadgil, A.; Martino Jannuzzi, G. de (Lawrence Berkeley Lab., CA (USA); Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia)

1989-07-01T23:59:59.000Z

440

Power Quality Improvements in Lighting Systems Mr. Ashish Shrivastava  

E-Print Network [OSTI]

from early incandescent lamps to present generation light emitting diodes (LEDs). Incandescent light

Kumar, M. Jagadesh

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Automated Podosome Identification and Characterization in Fluorescence Microscopy Images  

E-Print Network [OSTI]

B.M. Meddens,1 Bernd Rieger,2 Carl G. Figdor,1 Alessandra Cambi,1,3, * and Koen van den Dries1 1!. They have initially been identified in Src-transformed fibroblasts, and although previously thought to be restricted to only a few cell types, they have now been observed in smooth muscle cells, activated

Rieger, Bernd

442

Mechanism design with approximate types  

E-Print Network [OSTI]

In mechanism design, we replace the strong assumption that each player knows his own payoff type exactly with the more realistic assumption that he knows it only approximately: each player i only knows that his true type ...

Zhu, Zeyuan Allen

2012-01-01T23:59:59.000Z

443

Types of Farming in Texas.  

E-Print Network [OSTI]

.......... .......-.----------------------. 8 Labor -..-.....-----...------------------------------------------------. 9 Land Tenure .--.----....---....--------------------------------- 9 Number and Size of Farms ....----...----.-._--------- 10 Capital... -------------...-------.---------------------------- 21 Hogs -......-....--------------------------------------------------- 22 Poultry .-.---.-.....--.-..------.---------------------------------- 22 Horses and Mules ---..-....---..--..------------------------ 23 Types of Farming and Type-of-farming...

Bonnen, C. A.

1960-01-01T23:59:59.000Z

444

Zero energy-storage ballast for compact fluorescent lamps  

DOE Patents [OSTI]

A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast.

Schultz, William Newell (Niskayuna, NY); Thomas, Robert James (Rexford, NY)

1999-01-01T23:59:59.000Z

445

Hazard analysis of long term viewing of visible laser light off of fluorescent diffuse reflective surfaces (post-it).  

SciTech Connect (OSTI)

A laser hazard analysis is performed to evaluate if the use of fluorescent diffuse reflectors to view incident laser beams (Coherent Verdi 10W) present a hazard based on the ANSI Standard Z136.1-2000, American National Standard for the Safe Use of Lasers. The use of fluorescent diffuse reflectors in the alignment process does not pose an increased hazard because of the fluorescence at a different wavelength than that of the incident laser.

Augustoni, Arnold L.

2006-10-01T23:59:59.000Z

446

Tornado type wind turbines  

DOE Patents [OSTI]

A tornado type wind turbine has a vertically disposed wind collecting tower with spaced apart inner and outer walls and a central bore. The upper end of the tower is open while the lower end of the structure is in communication with a wind intake chamber. An opening in the wind chamber is positioned over a turbine which is in driving communication with an electrical generator. An opening between the inner and outer walls at the lower end of the tower permits radially flowing air to enter the space between the inner and outer walls while a vertically disposed opening in the wind collecting tower permits tangentially flowing air to enter the central bore. A porous portion of the inner wall permits the radially flowing air to interact with the tangentially flowing air so as to create an intensified vortex flow which exits out of the top opening of the tower so as to create a low pressure core and thus draw air through the opening of the wind intake chamber so as to drive the turbine.

Hsu, Cheng-Ting (Ames, IA)

1984-01-01T23:59:59.000Z

447

Method for detecting point mutations in DNA utilizing fluorescence energy transfer  

DOE Patents [OSTI]

A method for detecting point mutations in DNA using a fluorescently labeled oligomeric probe and Forster resonance energy transfer (FRET) is disclosed. The selected probe is initially labeled at each end with a fluorescence dye, which act together as a donor/acceptor pair for FRET. The fluorescence emission from the dyes changes dramatically from the duplex stage, wherein the probe is hybridized to the complementary strand of DNA, to the single strand stage, when the probe is melted to become detached from the DNA. The change in fluorescence is caused by the dyes coming into closer proximity after melting occurs and the probe becomes detached from the DNA strand. The change in fluorescence emission as a function of temperature is used to calculate the melting temperature of the complex or T.sub.m. In the case where there is a base mismatch between the probe and the DNA strand, indicating a point mutation, the T.sub.m has been found to be significantly lower than the T.sub.m for a perfectly match probelstand duplex. The present invention allows for the detection of the existence and magnitude of T.sub.m, which allows for the quick and accurate detection of a point mutation in the DNA strand and, in some applications, the determination of the approximate location of the mutation within the sequence.

Parkhurst, Lawrence J. (Lincoln, NE); Parkhurst, Kay M. (Lincoln, NE); Middendorf, Lyle (Lincoln, NE)

2001-01-01T23:59:59.000Z

448

Optimized scalable stack of fluorescent solar concentrator systems with bifacial silicon solar cells  

SciTech Connect (OSTI)

In this paper, we present a concentrator system based on a stack of fluorescent concentrators (FCs) and a bifacial solar cell. Coupling bifacial solar cells to a stack of FCs increases the performance of the system and preserves its efficiency when scaled. We used an approach to optimize a fluorescent solar concentrator system design based on a stack of multiple fluorescent concentrators (FC). Seven individual fluorescent collectors (20?mm?×?20?mm?×?2?mm) were realized by in-situ polymerization and optically characterized in regard to their ability to guide light to the edges. Then, an optimization procedure based on the experimental data of the individual FCs was carried out to determine the stack configuration that maximizes the total number of photons leaving edges. Finally, two fluorescent concentrator systems were realized by attaching bifacial silicon solar cells to the optimized FC stacks: a conventional system, where FC were attached to one side of the solar cell as a reference, and the proposed bifacial configuration. It was found that for the same overall FC area, the bifacial configuration increases the short-circuit current by a factor of 2.2, which is also in agreement with theoretical considerations.

Martínez Díez, Ana Luisa, E-mail: a.martinez@itma.es [Fundación ITMA, Parque Empresarial Principado de Asturias, C/Calafates, Parcela L-3.4, 33417 Avilés (Spain); Fraunhofer Institute for Solar Energy Systems ISE, Heidenhofstr. 2, 79110 Freiburg (Germany); Gutmann, Johannes; Posdziech, Janina; Rist, Tim; Goldschmidt, Jan Christoph [Fraunhofer Institute for Solar Energy Systems ISE, Heidenhofstr. 2, 79110 Freiburg (Germany); Plaza, David Gómez [Fundación ITMA, Parque Empresarial Principado de Asturias, C/Calafates, Parcela L-3.4, 33417 Avilés (Spain)

2014-10-21T23:59:59.000Z

449

X-Ray Fluorescence (XRF) Analysis of Obsidian Artifacts from AZ AA:8:20 (ASM), Southeastern Arizona  

E-Print Network [OSTI]

Minerologist 62:426-437. SOUTHWEST XRF PAPER Tabl;o:. X-:'~vX-RAY FLUORESCENCE (XRF) ANALYSIS OF OBSIDIAN ARTIFACTS FROM

Shackley, M. Steven

1986-01-01T23:59:59.000Z

450

Comparison of technologies for new energy-efficient lamps  

SciTech Connect (OSTI)

Energy-efficient light bulbs are being developed to replace the incandescent lamp where they can satisfy the design criteria and be used in sockets that have long hours of annual use. The four technologies discussed here include the compact fluorescent lamp, coated-filament lamp, electrodeless fluorescent lamp, and compact high-intensity discharge lamp. The systems demonstrate efficacy improvements of two to four times that of their incandescent counterparts. These new lamps have required considerable advances in lamp technology. They offer the potential for achieving efficacies close to 80 lumens per watt. These new lamps will reduce the energy used annually by incandescent lamps (190 BkWh) by more than 50% in the 1990s, at which times they will be commonly employed.

Verderber, R.R.; Rubinstein, F.R.

1983-06-01T23:59:59.000Z

451

Comparison of technologies for new energy-efficient lamps  

SciTech Connect (OSTI)

Energy-efficient light bulbs are being developed to replace the incandescent lamp where they can satisfy the design criteria and be used in sockets that have long hours of annual use. The four technologies discussed include the compact fluorescent lamp, coated-filament lamp, electrodeless fluorescent lamp, and compact high-intensity discharge lamp. The systems demonstrate efficacy improvements of two to four times that of their incandescent counterparts. These new lamps have required considerable advances in lamp technology. They offer the potential for achieving efficacies close to 80 lm/W. These new lamps will reduce the energy used annually by incandescent lamps (190 billion kWh) by more than 50 percent in the 1990's, at which times they will be commonly employed.

Verderber, R.R.; Rubinstein, F.M.

1984-09-01T23:59:59.000Z

452

Cost effective lighting  

SciTech Connect (OSTI)

Long-life replacement lamps for the incandescent lamp have been evaluated with regard to their cost effectiveness. The replacements include the use of energy buttons that extend lamp life as well as an adaptive fluorescent circline lamp that will fit into existing incandescent lamp sockets. The initial, operating, and replacement costs for one million lumen-hours are determined for each lamp system. We find the most important lighting cost component is the operating cost. Using lamps that are less efficient or devices that cause lamps to operate less efficiently are not cost-effective. The adaptive fluorescent circline lamp, even at an initial cost of $15.00, is the most cost effective source of illumination compared to the incandescent lamp and lamp systems examined. 3 refs., 6 tabs.

Morse, O.; Verderber, R.

1987-07-01T23:59:59.000Z

453

Third Level Trigger for the Fluorescence Telescopes of the Pierre Auger Observatory  

E-Print Network [OSTI]

The trigger system for the Auger fluorescence telescopes is implemented in hard- and software for an efficient selection of fluorescence light tracks induced by high-energy extensive air showers. The algorithm of the third stage uses the multiplicity signal of the hardware for fast rejection of lightning events with above 99% efficiency. In a second step direct muon hits in the camera and random triggers are rejected by analyzing the space-time correlation of the pixels. The trigger algorithm was tested with measured and simulated showers and implemented in the electronics of the fluorescence telescopes. A comparison to a prototype trigger without multiplicity shows the superiority of this approach, e.g. the false rejection rate is a factor 10 lower.

A. Schmidt; T. Asch; H. Gemmeke; M. Kleifges; H. -J. Mathes; A. Menshikov; F. Schüssler; D. Tcherniakhovski

2008-08-01T23:59:59.000Z

454

Third Level Trigger for the Fluorescence Telescopes of the Pierre Auger Observatory  

E-Print Network [OSTI]

The trigger system for the Auger fluorescence telescopes is implemented in hard- and software for an efficient selection of fluorescence light tracks induced by high-energy extensive air showers. The algorithm of the third stage uses the multiplicity signal of the hardware for fast rejection of lightning events with above 99% efficiency. In a second step direct muon hits in the camera and random triggers are rejected by analyzing the space-time correlation of the pixels. The trigger algorithm was tested with measured and simulated showers and implemented in the electronics of the fluorescence telescopes. A comparison to a prototype trigger without multiplicity shows the superiority of this approach, e.g. the false rejection rate is a factor 10 lower.

Schmidt, A; Gemmeke, H; Kleifges, M; Mathes, H -J; Menchikov, A; Schüssler, F; Tcherniakhovski, D

2008-01-01T23:59:59.000Z

455

Demonstration of x-ray fluorescence imaging of a high-energy-density plasma  

SciTech Connect (OSTI)

Experiments at the Trident Laser Facility have successfully demonstrated the use of x-ray fluorescence imaging (XRFI) to diagnose shocked carbonized resorcinol formaldehyde (CRF) foams doped with Ti. One laser beam created a shock wave in the doped foam. A second laser beam produced a flux of vanadium He-? x-rays, which in turn induced Ti K-shell fluorescence within the foam. Spectrally resolved 1D imaging of the x-ray fluorescence provided shock location and compression measurements. Additionally, experiments using a collimator demonstrated that one can probe specific regions within a target. These results show that XRFI is a capable alternative to path-integrated measurements for diagnosing hydrodynamic experiments at high energy density.

MacDonald, M. J., E-mail: macdonm@umich.edu; Gamboa, E. J. [Department of Atmospheric, Oceanic, and Space Sciences, University of Michigan, Ann Arbor, Michigan 48109 (United States); SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Keiter, P. A.; Fein, J. R.; Klein, S. R.; Kuranz, C. C.; LeFevre, H. J.; Manuel, M. J.-E.; Wan, W. C.; Drake, R. P. [Department of Atmospheric, Oceanic, and Space Sciences, University of Michigan, Ann Arbor, Michigan 48109 (United States); Montgomery, D. S. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Biener, M. M.; Fournier, K. B. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Streit, J. [Schafer Corporation, Livermore, California 94551 (United States)

2014-11-15T23:59:59.000Z

456

Fluorescence measurements for evaluating the application of multivariate analysis techniques to optically thick environments.  

SciTech Connect (OSTI)

Laser-induced fluorescence measurements of cuvette-contained laser dye mixtures are made for evaluation of multivariate analysis techniques to optically thick environments. Nine mixtures of Coumarin 500 and Rhodamine 610 are analyzed, as well as the pure dyes. For each sample, the cuvette is positioned on a two-axis translation stage to allow the interrogation at different spatial locations, allowing the examination of both primary (absorption of the laser light) and secondary (absorption of the fluorescence) inner filter effects. In addition to these expected inner filter effects, we find evidence that a portion of the absorbed fluorescence is re-emitted. A total of 688 spectra are acquired for the evaluation of multivariate analysis approaches to account for nonlinear effects.

Reichardt, Thomas A.; Timlin, Jerilyn Ann; Jones, Howland D. T.; Sickafoose, Shane M.; Schmitt, Randal L.

2010-09-01T23:59:59.000Z

457

Fluorescence of PRODAN in Water: a Computational QM/MM MD Study  

SciTech Connect (OSTI)

Fluorescent properties of PRODAN (6-propionyl-2-dimethylaminonaphthalene) in water were studied by means of excited state molecular dynamics simulations employing a combined quantum mechanical and molecular mechanical approach with the time-dependent density functional theory (TD-DFT QM/MM MD). The state of the art coupled cluster method was used to benchmark density functional theory calculations. The influence of the water environment on PRODAN emission was investigated by employing several computational schemes with varying description of the solvent. The issue of the molecular geometry of the excited state PRODAN molecule in water was addressed. The experimental emission spectrum was reproduced for the planar excited state conformer of PRODAN in the extended environment of 300 explicit water molecules. The planar conformer was shown to be predominantly responsible for fluorescence. The twisted isomer is strongly stabilized in water, but rapidly evolve towards a conical intersection, and hence the twisted conformer is fluorescently inactive.

Pederzoli, Marek; Sobek, Lukas; Brabec, Jiri; Kowalski, Karol; Cwiklik, Lukasz; Pittner, Jiri

2014-03-28T23:59:59.000Z

458

Intense Internal and External Fluorescence as Solar Cells Approach the Shockley-Queisser Efficiency Limit  

E-Print Network [OSTI]

Absorbed sunlight in a solar cell produces electrons and holes. But, at the open circuit condition, the carriers have no place to go. They build up in density and, ideally, they emit external fluorescence that exactly balances the incoming sunlight. Any additional non-radiative recombination impairs the carrier density buildup, limiting the open-circuit voltage. At open-circuit, efficient external fluorescence is an indicator of low internal optical losses. Thus efficient external fluorescence is, counter-intuitively, a necessity for approaching the Shockley-Queisser efficiency limit. A great Solar Cell also needs to be a great Light Emitting Diode. Owing to the narrow escape cone for light, efficient external emission requires repeated attempts, and demands an internal luminescence efficiency >>90%.

Miller, Owen D; Kurtz, Sarah R

2012-01-01T23:59:59.000Z

459

Laser-induced fluorescence of fused silica irradiated by ArF excimer laser  

SciTech Connect (OSTI)

Laser-induced fluorescence (LIF) of high-purity fused silica irradiated by ArF excimer laser is studied experimentally. LIF bands of the fused silica centered at 281 nm, 478 nm, and 650 nm are observed simultaneously. Furthermore, the angular distribution of the three fluorescence peaks is examined. Microscopic image of the laser modified fused silica indicates that scattering of the generated fluorescence by laser-induced damage sites is the main reason for the angular distribution of LIF signals. Finally, the dependence of LIF signals intensities of the fused silica on laser power densities is presented. LIF signals show a squared power density dependence, which indicates that laser-induced defects are formed mainly via two-photon absorption processes.

Zhang Haibo [Shanghai Key Laboratory of All Solid-state Laser and Applied Techniques, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Science, Shanghai 201800 (China); Graduate University of Chinese Academy of Science, Beijing 100049 (China); Yuan Zhijun; Zhou Jun; Dong Jingxing; Wei Yunrong; Lou Qihong [Shanghai Key Laboratory of All Solid-state Laser and Applied Techniques, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Science, Shanghai 201800 (China)

2011-07-01T23:59:59.000Z

460

Zero energy-storage ballast for compact fluorescent lamps  

DOE Patents [OSTI]

A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast. 4 figs.

Schultz, W.N.; Thomas, R.J.

1999-08-31T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Fluorescent and cathodoluminescent phophors structurally related to sodalite  

DOE Patents [OSTI]

Blue, quantum-confined phosphors for field-emission displays made by reducing metal (M) sulfoaluminates at high temperature. This yields phases of the type M.sub.4 (AlO.sub.2).sub.6 S. Bulk sulfide contaminant mixed with the reduced sulfoaluminate phase is removed by treating it with a chelating agent in nonaqueous solution. A photometric cathodoluminescence efficiency of 9 lumen/watt at 1000 V for Sr.sub.3 PbS(AlO.sub.2).sub.6 is observed. Undoped Sr.sub.4 S(AlO).sub.6 displays 5 lumen/watt at 1000 V, with excellent blue chromatic saturation.

Phillips, Mark L. F. (Tijeras, NM); Shea, Lauren E. (San Diego, CA)

1998-01-01T23:59:59.000Z

462

Midterm #2 Solutions – EECS 145L Fall 2003 1a Properties that differ Pt resistance thermometer Thermocouple  

E-Print Network [OSTI]

material metal semiconductor R with increasing T linear increase exponential decrease maximum temperature high (800 °C) low (100 °C) [full credit for 2 correct different properties; 2 points off for each missing entry] 1b Properties that differ Incandescent lamp Fluorescent lamp temperature hot (3000K filament) cool mechanism black body radiation discrete energy change of electrons wavelength spectrum broad discrete lines energy efficiency low high [full credit for 2 correct different properties; 2 points off for each missing entry] 1c Properties that differ PIN photodiode Light Emitting Diode (LED) input photons current output current photons electronic transducer type sensor actuator [full credit for 2 correct different properties; 2 points off for each missing entry

unknown authors

463

Subunits of highly Fluorescent Protein R-Phycoerythrin as Probes for Cell Imaging and Single-Molecule Detection  

SciTech Connect (OSTI)

The purposes of our research were: (1) To characterize subunits of highly fluorescent protein R-Phycoerythrin (R-PE) and check their suitability for single-molecule detection (SMD) and cell imaging, (2) To extend the use of R-PE subunits through design of similar proteins that will be used as probes for microscopy and spectral imaging in a single cell, and (3) To demonstrate a high-throughput spectral imaging method that will rival spectral flow cytometry in the analysis of individual cells. We first demonstrated that R-PE subunits have spectroscopic and structural characteristics that make them suitable for SMD. Subunits were isolated from R-PE by high-performance liquid chromatography (HPLC) and detected as single molecules by total internal reflection fluorescence microscopy (TIRFM). In addition, R-PE subunits and their enzymatic digests were characterized by several separation and detection methods including HPLC, capillary electrophoresis, sodium dodecyl sulfate-polyacrilamide gel electrophoresis (SDS-PAGE) and HPLC-electrospray ionization mass spectrometry (ESI-MS). Favorable absorption and fluorescence of the R-PE subunits and digest peptides originate from phycoerythrobilin (PEB) and phycourobilin (PUB) chromophores that are covalently attached to cysteine residues. High absorption coefficients and strong fluorescence (even under denaturing conditions), broad excitation and emission fluorescence spectra in the visible region of electromagnetic spectrum, and relatively low molecular weights make these molecules suitable for use as fluorescence labels of biomolecules and cells. We further designed fluorescent proteins both in vitro and in vivo (in Escherichia coli) based on the highly specific attachment of PEB chromophore to genetically expressed apo-subunits of R-PE. In one example, apo-alpha and apo-beta R-PE subunits were cloned from red algae Polisiphonia boldii (P. boldii), and expressed in E. coli. Although expressed apo-subunits formed inclusion bodies, fluorescent holo-subunits were formed after incubation of E. coli cells with PEB. Spectroscopic characterization of holo-subunits confirmed that the attachment of PEB chromophore to apo-subunits yielded holo-subunits containing both PEB and urobilin (UB). Fluorescence and differential interference contrast (DIC) microscopy showed polar location of holo-subunit inclusion bodies in E. coli cells. In another example, R-PE apo-subunits were genetically fused to cytoplasmic and periplasmic versions of E. coli maltose binding protein (MBP). Fluorescent proteins formed after attachment of PEB to MBP-subunit fusions in vitro and in vivo contained PEB as the sole chromophore, were soluble, and displayed high orange fluorescence. Fluorescence microscopy showed that fusions are located either throughout cells or at cell poles. In addition, cells containing fluorescent holo-subunits or MBP-subunit fusions were up to ten times brighter than control cells as measured by flow cytometry. Results show that the fluorescent proteins formed after non-enzymatic attachment of PEB to R-PE subunit fusions could be used as reporters of gene expression and protein localization in cells as well as fluorescence labels in flow cytometry. Finally, we demonstrated a high-throughput method able to record emission fluorescence spectra of individual cells containing fluorescent proteins. Upon excitation with a 488 mn argon-ion laser many bacterial cells were imaged by a 20X microscope objective while they moved through a capillary tube. Fluorescence was dispersed by a transmission diffraction grating, and an intensified charge-coupled device (ICCD) camera simultaneously recorded the zero and the first orders of the fluorescence from each cell. Single-cell fluorescence spectra were reconstructed from the distance between zero-order and first-order maxima as well as the length and the pixel intensity distribution of the first-order images. By using this approach, the emission spectrum of E. coli cells expressing green fluorescent protein (GFP) was reconstructed. Also, fluorescence spectra of E

Dragan Isailovic

2005-12-17T23:59:59.000Z

464

New maturity indicators based on spectral fluorescence of alginite and bitumen, Monterey Formation, California  

SciTech Connect (OSTI)

Conventional assessment of maturation level in the Monterey has been problematic, since sporinite and vitrinite are rare or absent. Organic matter is largely alginite and amorphous material, and reliable vitrinite reflectance (R{sub o}%) and Thermal Alteration Index (TAI) are difficult to obtain. Large amounts of bitumen often imbedded in the highly fractured Monterey shales cause a suppression of T{sub max} and low values of S{sub 1}S{sub 1} + S{sub 2}. It is often difficult to determine whether bitumen is indigenous or migrated from other more mature strata. Spectral fluorescence measurements of alginite and bitumen have proved useful in assessing the maturity of the Monterey. A maturity scale based on red/green quotient (Q{sub v}) measured as the fluorescence of alginite B when excited by violet-light has been developed and applied to the Monterey. Alginite B is common in the Monterey, and accurate fluorescent measurements can be readily obtained given the highly fluorescent character of alginite B. A total scanning fluorescence technique was used to develop a maturity scale based on bitumen aromatic content and composition. The maturity parameter (R{sub 1}) developed in this study uses the intensity of fluorescence emitted at 360 nm ratioed to that at 320 nm when the solvent-dissolved bitumen is excited at the 270 nm. These parameters allow for the evaluation of the thermal maturity of algal organic matter and bitumen from the Monterey with R{sub o}% {lt} 1. Indigenous bitumen is also indicated by a comparison of maturity based on Q{sub v} (the solid phase) and bitumen maturity (the liquid phase) based on R{sub 1}.

Lee, Chungi; Kennicutt, M.C. II (Texas A and M Univ., College Station (United States)); Lo, H.B. (Exxon Production Research Co., Houston, TX (United States))

1991-03-01T23:59:59.000Z

465

A portable time-domain LED fluorimeter for nanosecond fluorescence lifetime measurements  

SciTech Connect (OSTI)

Fluorescence lifetime measurements are becoming increasingly important in chemical and biological research. Time-domain lifetime measurements offer fluorescence multiplexing and improved handling of interferers compared with the frequency-domain technique. In this paper, an all solid-state, filterless, and highly portable light-emitting-diode based time-domain fluorimeter (LED TDF) is reported for the measurement of nanosecond fluorescence lifetimes. LED based excitation provides more wavelengths options compared to laser diode based excitation, but the excitation is less effective due to the uncollimated beam, less optical power, and longer latency in state transition. Pulse triggering and pre-bias techniques were implemented in our LED TDF to improve the peak optical power to over 100 mW. The proposed pulsing circuit achieved an excitation light fall time of less than 2 ns. Electrical resetting technique realized a time-gated photo-detector to remove the interference of the excitation light with fluorescence. These techniques allow the LED fluorimeter to accurately measure the fluorescence lifetime of fluorescein down to concentration of 0.5 ?M. In addition, all filters required in traditional instruments are eliminated for the non-attenuated excitation/emission light power. These achievements make the reported device attractive to biochemical laboratories seeking for highly portable lifetime detection devices for developing sensors based on fluorescence lifetime changes. The device was initially validated by measuring the lifetimes of three commercial fluorophores and comparing them with reported lifetime data. It was subsequently used to characterize a ZnSe quantum dot based DNA sensor.

Wang, Hongtao; Salthouse, Christopher D., E-mail: salthouse@ecs.umass.edu [Electrical and Computer Engineering Department, University of Massachusetts, Amherst, Massachusetts 01003 (United States); Center for Personalized Health Monitoring, University of Massachusetts, Amherst, Massachusetts 01003 (United States); Qi, Ying; Mountziaris, T. J. [Center for Personalized Health Monitoring, University of Massachusetts, Amherst, Massachusetts 01003 (United States) [Center for Personalized Health Monitoring, University of Massachusetts, Amherst, Massachusetts 01003 (United States); Chemical Engineering Department, University of Massachusetts, Amherst, Massachusetts 01003 (United States)

2014-05-15T23:59:59.000Z

466

On the asymptotic homotopy type of inductive limit Type ...  

E-Print Network [OSTI]

In this note we exhibit large classes of (projeetionless) stable, nuclear C*- algebras whose asymptotic homotopy type is determined by K-theoretical data.

467

Measurement of Pressure Dependent Fluorescence Yield of Air: Calibration Factor for UHECR Detectors  

SciTech Connect (OSTI)

In a test experiment at the Final Focus Test Beam of the Stanford Linear Accelerator Center, the fluorescence yield of 28.5 GeV electrons in air and nitrogen was measured. The measured photon yields between 300 and 400 nm at 1 atm and 29 C are Y(760 Torr){sup air} = 4.42 {+-} 0.73 and Y(760 Torr){sup N{sub 2}} = 29.2 {+-} 4.8 photons per electron per meter. Assuming that the fluorescence yield is proportional to the energy deposition of a charged particle traveling through air, good agreement with measurements at lower particle energies is observed.

Belz, J.W.; Burt, G.W.; Cao, Z.; Chang, F.Y.; Chen, C.C.; Chen, C.W.; Chen, P.; Field, C.; Findlay, J.; Huntemeyer, Petra; Huang, M.A.; Hwang, W.-Y.P.; Iverson, R.; Jones, B.F.; Jui, C.C.H.; Kirn, M.; Lin, G.-L.; Loh, E.C.; Maestas, M.M.; Manago, N.; Martens, K.; /Montana U. /Utah U. /Taiwan, Natl. Taiwan U. /SLAC /Rutgers U., Piscataway

2005-07-06T23:59:59.000Z

468

X-RAY FLUORESCENCE ANALYSIS OF HANFORD LOW ACTIVITY WASTE SIMULANTS METHOD DEVELOPMENT  

SciTech Connect (OSTI)

The x-ray fluorescence laboratory (XRF) in the Analytical Development Directorate (ADD) of the Savannah River National Laboratory (SRNL) was requested to develop an x-ray fluorescence spectrometry method for elemental characterization of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) pretreated low activity waste (LAW) stream to the LAW Vitrification Plant. The WTP is evaluating the potential for using XRF as a rapid turnaround technique to support LAW product compliance and glass former batching. The overall objective of this task was to develop an XRF analytical method that provides rapid turnaround time (<8 hours), while providing sufficient accuracy and precision to determine variations in waste.

Jurgensen, A; David Missimer, D; Ronny Rutherford, R

2007-08-08T23:59:59.000Z

469

Simultaneous two-dimensional laser-induced-fluorescence measurements of argon ions  

SciTech Connect (OSTI)

Recent laser upgrades on the Hot Helicon Experiment at West Virginia University have enabled multiplexed simultaneous measurements of the ion velocity distribution function at a single location, expanding our capabilities in laser-induced fluorescence diagnostics. The laser output is split into two beams, each modulated with an optical chopper and injected perpendicular and parallel to the magnetic field. Light from the crossing point of the beams is transported to a narrow-band photomultiplier tube filtered at the fluorescence wavelength and monitored by two lock-in amplifiers, each referenced to one of the two chopper frequencies.

Hansen, A. K.; Galante, Matthew; McCarren, Dustin; Sears, Stephanie; Scime, E. E. [Department of Physics, West Virginia University, P.O. Box 6315, Morgantown, West Virginia 26506-6315 (United States)

2010-10-15T23:59:59.000Z

470

Investigation and technique in the fluorescent spectra examination of crude oil  

E-Print Network [OSTI]

by chromato- graphy and distillation. The adsorbent was Alcoa activated alumina, chromatographic grade F-20. Support for the adsorbent was Pyrex brand glass fibre and cleaned B 0, A. sea sand. 11 DEVELOPl';, 'EI&T OF TEOHN IQUE Fluorescent intensity..., the cut between 2F2 and 2P$ was exactly between the two bands. The similarity of the fluorescent spectra of 1E1, 1E2, and 1E?i with 2F1, 2P2, and 2F$ (Figures 11, 12, 1B and 19) shows the similarity in the developing power of chloroform and. ether. A...

Chambers, Gilbert Vester

1958-01-01T23:59:59.000Z

471

Method for detecting binding events using micro-X-ray fluorescence spectrometry  

DOE Patents [OSTI]

Method for detecting binding events using micro-X-ray fluorescence spectrometry. Receptors are exposed to at least one potential binder and arrayed on a substrate support. Each member of the array is exposed to X-ray radiation. The magnitude of a detectable X-ray fluorescence signal for at least one element can be used to determine whether a binding event between a binder and a receptor has occurred, and can provide information related to the extent of binding between the binder and receptor.

Warner, Benjamin P. (Los Alamos, NM); Havrilla, George J. (Los Alamos, NM); Mann, Grace (Hong Kong, HK)

2010-12-28T23:59:59.000Z

472

A Review of the Reflector Compact Fluorescent Lights Technology Procurement Program: Conclusions and Results  

SciTech Connect (OSTI)

This report describes a project sponsored by the U.S. Department of Energy (DOE) and implemented by the Pacific Northwest National Laboratory (PNNL), from 2000 to 2007 to improve the performance of reflector type (R-lamp) compact fluorescent lamps (CFLs) and increase their availability throughout the United States by means of a technology development and procurement strategy. In 2000, at the request of the U.S. Department of Energy’s Emerging Technologies Program and its predecessors, the Pacific Northwest National Laboratory undertook a technology procurement seeking R-CFLs that were specifically designed for use in ICAT recessed can fixtures and that met other minimum performance criteria including minimum light output and size restrictions (to ensure they fit in standard residential recessed cans). The technology procurement included two phases. In Phase I, requests for proposals (RFPs) were issued in October 2002 and five manufacturers responded with 12 lamp models. Eight of these models met the minimum requirements and passed the 6-hour short-term test in a simulated ICAT environment. These eight models were subjected to long-term tests of 6,000 or more hours in a simulated ICAT environment. Three of these models passed the short- and long-term tests and were promoted through the program website (www.pnl.gov/rlamps), press releases, and fliers. To increase the number of qualifying models, a second RFP was issued in June 2005. In April 2007, DOE announced that 16 reflector CFL (R-CFL) models by four manufacturers had met all the minimum requirements of Phase 2 of the R-CFL Technology Innovation Competition. PNNL developed both the criteria and the test apparatus design for Elevated Temperature Life Testing (ETLT), which has been included by DOE in its draft ENERGY STAR specifications for the reflector category of CFLs. PNNL promoted the winning lamps through a program website, press releases, and fliers as well as through program partners. PNNL also helped engage distributors including Costco, the Home Depot, Bonneville Power Administration, and utility organizations.

Sandahl, Linda J.; Gilbride, Theresa L.; Ledbetter, Marc R.; McCullough, Jeffrey J.

2008-05-19T23:59:59.000Z

473

Visualization of the African swine fever virus infection in living cells by incorporation into the virus particle of green fluorescent protein-p54 membrane protein chimera  

SciTech Connect (OSTI)

Many stages of African swine fever virus infection have not yet been studied in detail. To track the behavior of African swine fever virus (ASFV) in the infected cells in real time, we produced an infectious recombinant ASFV (B54GFP-2) that expresses and incorporates into the virus particle a chimera of the p54 envelope protein fused to the enhanced green fluorescent protein (EGFP). The incorporation of the fusion protein into the virus particle was confirmed immunologically and it was determined that p54-EGFP was fully functional by confirmation that the recombinant virus made normal-sized plaques and presented similar growth curves to the wild-type virus. The tagged virus was visualized as individual fluorescent particles during the first stages of infection and allowed to visualize the infection progression in living cells through the viral life cycle by confocal microscopy. In this work, diverse potential applications of B54GFP-2 to study different aspects of ASFV infection are shown. By using this recombinant virus it was possible to determine the trajectory and speed of intracellular virus movement. Additionally, we have been able to visualize for first time the ASFV factory formation dynamics and the cytophatic effect of the virus in live infected cells. Finally, we have analyzed virus progression along the infection cycle and infected cell death as time-lapse animations.

Hernaez, Bruno [Departamento de Biotecnologia, INIA, Carretera de la Coruna Km 7, 28040 Madrid (Spain)]. E-mail: hernaez@inia.es; Escribano, Jose M. [Departamento de Biotecnologia, INIA, Carretera de la Coruna Km 7, 28040 Madrid (Spain)]. E-mail: escriban@inia.es; Alonso, Covadonga [Departamento de Biotecnologia, INIA, Carretera de la Coruna Km 7, 28040 Madrid (Spain)]. E-mail: calonso@inia.es

2006-06-20T23:59:59.000Z

474

Fluorescent and cathodoluminescent phosphors structurally related to sodalite  

DOE Patents [OSTI]

Blue, quantum-confined phosphors are disclosed for field-emission displays made by reducing metal (M) sulfoaluminates at high temperature. This yields phases of the type M{sub 4}(AlO{sub 2}){sub 6}S. Bulk sulfide contaminant mixed with the reduced sulfoaluminate phase is removed by treating it with a chelating agent in nonaqueous solution. A photometric cathodoluminescence efficiency of 9 lumen/watt at 1,000 V for Sr{sub 3}PbS(AlO{sub 2}){sub 6} is observed. Undoped Sr{sub 4}S(AlO){sub 6} displays 5 lumen/watt at 1,000 V, with excellent blue chromatic saturation. 2 figs.

Phillips, M.L.F.; Shea, L.E.

1998-09-29T23:59:59.000Z

475

Confocal X-ray Fluorescence (XRF) Microscopy: A New Technique for the Nondestructive Compositional Depth Profiling of Paintings  

E-Print Network [OSTI]

#12;Confocal X-ray Fluorescence (XRF) Microscopy: A New Technique for the Nondestructive tools such as x-ray fluorescence (XRF) [4,5,6,7] and proton-induced x-ray emission (PIXE) [3,8,9] to address the problem of compositional depth profiling of paintings. One XRF method consists of deducing

Gruner, Sol M.

476

Reversible Modification of CdSe-CdS/ZnS Quantum Dot Fluorescence by Surrounding Ca2+  

E-Print Network [OSTI]

Reversible Modification of CdSe-CdS/ZnS Quantum Dot Fluorescence by Surrounding Ca2+ Ions Li Li (3-MPA) coated CdSe-CdS/ZnS core-multishell QDs when free Ca2+ ions were added to and subsequently removed from the QD solution. It was found that QD fluorescence intensity was reduced when Ca2+ ions were

Haviland, David

477

First-Principles Characterization of the Energy Landscape and Optical Spectra of Green Fluorescent Protein along the AIB  

E-Print Network [OSTI]

First-Principles Characterization of the Energy Landscape and Optical Spectra of Green Fluorescent Supporting Information ABSTRACT: Structures and optical spectra of the green fluorescent protein (GFP) forms-form) is lowest in energy, whereas the systems with the anionic chromophore (B- and I-forms) are about 1 kcal

Krylov, Anna I.

478

Single-Molecule Fluorescence Studies of Protein Folding and Conformational Xavier Michalet,* Shimon Weiss, and Marcus Jager*  

E-Print Network [OSTI]

Single-Molecule Fluorescence Studies of Protein Folding and Conformational Dynamics Xavier Michalet. Single-Molecule Fluorescence Studies of Protein Folding and Conformations at Equilibrium 1796 4-Molecule Protein Folding under Nonequilibrium Conditions 1808 6. Conclusion 1809 7. Acknowledgments 1810 8

Michalet, Xavier

479

Global analysis of Fo rster resonance energy transfer in live cells measured by fluorescence lifetime imaging microscopy exploiting  

E-Print Network [OSTI]

Global analysis of Fo¨ rster resonance energy transfer in live cells measured by fluorescence of Fo¨ rster resonance energy transfer (FRET) in live cells using the rise time of acceptor fluorescence those molecules that are involved in the energy-transfer process are monitored. This contrasts

van Stokkum, Ivo

480

Analysis of the methods for the derivation of binary kinetic equations in the theory of fluorescence concentration quenching  

SciTech Connect (OSTI)

In the framework of unified many-particle approach the familiar problem of fluorescence concentration quenching in the presence of pumping (light pulse) of arbitrary intensity is considered. This process is a vivid and the simplest example of multistage bulk reaction including bimolecular irreversible quenching reaction and reversible monomolecular transformation as elementary stages. General relation between the kinetics of multistage bulk reaction and that of the elementary stage of quenching has been established. This allows one to derive general kinetic equations (of two types) for the multistage reaction in question on the basis of general kinetic equations (differential and integro-differential) of elementary stage of quenching. Relying on the same unified many-particle approach we have developed binary approximations with the use of two (frequently employed in the literature) many-particle methods (such as simple superposition approximation and the method of extracting pair channels in three-particle correlation evolution) to the derivation of non-Markovian binary kinetic equations. The possibility of reducing the obtained binary equations to the Markovian equations of formal chemical kinetics has been considered. As an example the exact solution of the problem (for the specific case) is examined, and the applicability of two many particle methods of derivation of binary equations is analyzed.

Doktorov, A. B. [Voevodsky Institute of Chemical Kinetics and Combustion, Siberian Branch of the Russian Academy of Sciences, Novosibirsk 630090, Russia and Physics Department Novosibirsk State University, Novosibirsk 630090 (Russian Federation)

2014-09-14T23:59:59.000Z

Note: This page contains sample records for the topic "type incandescent fluorescent" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Fluorescence Efficiency and Stability of Radio-Pure Tetraphenyl-butadiene Based Coatings for VUV Light Detection in Cryogenic Environments  

E-Print Network [OSTI]

The detection of VUV scintillation light, e.g. in (liquid) argon detectors, commonly includes a reflector with a fluorescent coating, converting UV photons to visible light. The light yield of these detectors depends directly on the conversion efficiency. Several coating/reflector combinations were produced using VM2000, a specular reflecting multi layer polymer, and Tetratex, a diffuse reflecting PTFE fabric, as reflector foils. The efficiency of these coatings was optimised and has been measured in a dedicated liquid argon setup built at the University of Zurich. It employs a small, 1.3 kg LAr cell viewed by a 3-inch, low radioactivity PMT of type R11065-10 from Hamamatsu. The cryogenic stability of these coatings was additionally studied. The optimum reflector/coating combination was found to be Tetratex dip coated with Tetraphenyl-butadiene with a thickness of 0.9 mg/cm$^2$ resulting in a 3.6 times higher light yield compared to uncoated VM2000. Its performance was stable in long term measurements, ran up...

Baudis, Laura; Dressler, Rugard; Piastra, Francesco; Usoltsev, Ilya; Walter, Manuel

2015-01-01T23:59:59.000Z

482

Excitation of sensitized fluorescence of europium and curium in an aqueous solution of thenoyltrifluoroacetone by a nitrogen laser  

SciTech Connect (OSTI)

The fluorescence spectrum of trivalent europium in aqueous solutions of thenoyltrifluoroacetone, excited by a nitrogen laser with emission wavelength 337 nm, exhibits bands at 582, 593, 616, 650, and 695 nm. Two bands appear in the fluorescence spectrum of trivalent curium under the same conditions - at 598 and 607 nm. The times of quenching of the fluorescence of the ions of these elements were measured, both in H/sub 2/O medium and in D/sub 2/O. A linear relationship was found between the fluorescence intensity of europium and curium and their concentration in TTA solution. The limit of determination of europium and curium by the fluorescent method with laser excitation using the bands at 615 and 607 nm proved equal to 0.3 and 0.07 ng/ml, respectively.

Dem'yanova, T.A.; Stepanov, A.V.; Babaev, A.S.; Aleksandruk, V.M.

1987-03-01T23:59:59.000Z

483

Fluorescent silica colloids for study and visualization of skin care products  

E-Print Network [OSTI]

due to long exposures to cold and dry air (7). Different skin care products are used to hy- drate dryFluorescent silica colloids for study and visualization of skin care products Swaminathan Iyer: The efficacy of skin care products depends on the time and dynamics of their absorbance by the skin, and its

Sokolov, Igor

484

Deep-Sea Research I 50 (2003) 417434 Phytoplankton natural fluorescence variability in the  

E-Print Network [OSTI]

capacity and community composi- tion. Solar-stimulated, or ``natural'' fluorescence is a passive of California, Santa Barbara, Santa Barbara, CA 93106-3060, USA Received 10 October 2001; received in revised Science, University of California, Santa Barbara, Santa Barbara, CA 93106-3060, USA. Fax: +1

California at Santa Barbara, University of

485

FOCUS www.rsc.org/loc | Lab on a Chip Improving fluorescence detection in lab on  

E-Print Network [OSTI]

) graft on glass. Two cell populations are separately labeled with live cell dyes and are mixed and seeded and sensitivity, due primarily to sub-optimal light collection. More sensi- tive, higher resolution LOC devices for performing high-sensitivity and high-resolution fluo- rescence detection within LOC devices. Fluorescence

Fygenson, Deborah Kuchnir

486

Hybrid Electrochromic Fluorescent Poly(DNTD)/CdSe@ZnS Composite Films  

E-Print Network [OSTI]

Hybrid Electrochromic Fluorescent Poly(DNTD)/CdSe@ZnS Composite Films Huige Wei, Xingru Yan, Springdale, Arkansas 72764, United States ABSTRACT: Hybrid electrochromic poly(DNTD)/CdSe@ZnS quantum dots of an electrical current after the application of an appropriate electrode potential.15-17 The electrochromic

Guo, John Zhanhu

487

Fluorescent probes for non-invasive bioenergetic studies of whole cyanobacterial cells  

E-Print Network [OSTI]

Fluorescent probes for non-invasive bioenergetic studies of whole cyanobacterial cells Markus of bioenergetic processes in whole cells of the cyanobacterium Synechocystis sp. PCC 6803. Acridine yellow to be created. In sum- mary, bioenergetic £uorescence measurement com- bines the advantages of an easy

Roegner, Matthias

488

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

DOE Patents [OSTI]

A novel design is described for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment. 9 figs.

Siminovitch, M.

1998-02-10T23:59:59.000Z

489

Laboratory investigation of triple marking the parasitoid Gonatocerus ashmeadi with a fluorescent dye and  

E-Print Network [OSTI]

dye and two animal proteins N. A. Irvin1 *, J. R. Hagler2 & M. S. Hoddle1,3 1 Department of Entomology: ELISA, protein marking, dye marking, mark­capture, survival, Hymenoptera, Mymari- dae, glassy in chicken eggs, casein in bovine milk, and SARDI yellow fluorescent dye. Three application treatments

Hoddle, Mark S.

490

Aerial Imaging of Fluorescent Dye in the Near Shore DAVID B. CLARK  

E-Print Network [OSTI]

Aerial Imaging of Fluorescent Dye in the Near Shore DAVID B. CLARK Woods Hole Oceanographic) dye in turbid and optically deep water. Tracer releases near the shoreline of an ocean beach and near of upwelling radiance near the Rhodamine WT excitation and emission peaks varies linearly with the in situ dye

Boss, Emmanuel S.

491

Accretion, fluorescent X-ray emission and flaring magnetic structures in YSOs  

E-Print Network [OSTI]

I present some recent developments on high-energy phenomena in YSOs, concentrating on the new evidence for accretion-induced X-ray emission in YSOs, for Fe 6.4 keV fluorescent emission from the disks of YSOs and for very long magnetic structures responsible for intense X-ray flares, likely connecting the star and the circumstellar disk.

F. Favata

2004-12-20T23:59:59.000Z

492

Dimeric fluorescent energy transfer dyes comprising asymmetric cyanine azole-indolenine chromophores  

DOE Patents [OSTI]

Novel fluorescent DNA-staining dyes are provided combining asymmetric cyanine azole-indolenine dyes, which provide for strong DNA affinity, large Stokes shifts and emission in the red region of the spectrum. The dyes find particular application in gel electrophoresis and for labels which may be bound to a variety of compositions in a variety of contexts.

Glazer, Alexander N. (Orinda, CA); Benson, Scott C. (Albany, CA)

1996-01-01T23:59:59.000Z

493

Improved fluorescence-enhanced optical imaging and tomography by enhanced excitation light rejection  

E-Print Network [OSTI]

match for tomographic reconstruction of one (1 cm3) and two (0.1 cm3) targets in a 1087 cm3 of breast phantom. Ultimately, this work improves the sensitivity of NIR fluorescence imaging by enhancing the rejection of excitation light and shows...

Hwang, Kil Dong

2009-05-15T23:59:59.000Z

494

Sensors and Actuators B 107 (2005) 121125 Two photon fluorescence sensors based on resonant grating  

E-Print Network [OSTI]

Sensors and Actuators B 107 (2005) 121­125 Two photon fluorescence sensors based on resonant the excitation and emission radia- tion reduces the background noise, the static photobleaching.07.040 #12;122 T. Katchalski et al. / Sensors and Actuators B 107 (2005) 121­125 lar, they are compact

Friesem, Asher A.

495

A Microfluidic Device for Temporally Controlled Gene Expression and Long-Term Fluorescent Imaging in  

E-Print Network [OSTI]

A Microfluidic Device for Temporally Controlled Gene Expression and Long-Term Fluorescent Imaging of the cell cycle. Over the past ten years, microfluidic techniques in cell biology have emerged that allow a microfluidic flow cell to grow Saccharomyces Cerevisiae for more than 8 generations (

Siggia, Eric

496

RNA Degradation in Cell Extracts: Real-Time Monitoring by Fluorescence Resonance Energy Transfer (FRET)  

E-Print Network [OSTI]

S1 RNA Degradation in Cell Extracts: Real-Time Monitoring by Fluorescence Resonance Energy TransferM PMSF; we found the pH after dialysis to be 7.6. UV Melting Curves: 1 µM unlabeled or doubly fluorophore wavelength for a UV melting experiment, and the signal at 320 nm was subtracted as background. Temperatures

Walter, Nils G.

497

Intercellular trafficking of a KNOTTED1 green fluorescent protein fusion in the leaf and  

E-Print Network [OSTI]

Intercellular trafficking of a KNOTTED1 green fluorescent protein fusion in the leaf and shoot Jackson¶ Cold Spring Harbor Laboratory, Watson School of Biological Sciences, 1 Bungtown Road, Cold Spring between epidermal cells of Arabidopsis and onion. When expressed in vivo, the GFP KN1 fusion trafficked

Jackson, David

498

Fluorescence technique for on-line monitoring of state of hydrogen-producing microorganisms  

DOE Patents [OSTI]

In situ fluorescence method to monitor state of sulfur-deprived algal culture's ability to produce H.sub.2 under sulfur depletion, comprising: a) providing sulfur-deprived algal culture; b) illuminating culture; c) measuring onset of H.sub.2 percentage in produced gas phase at multiple times to ascertain point immediately after anerobiosis to obtain H.sub.2 data as function of time; and d) determining any abrupt change in three in situ fluorescence parameters; i) increase in F.sub.t (steady-state level of chlorophyll fluorescence in light adapted cells); ii) decrease in F.sub.m', (maximal saturating light induced fluorescence level in light adapted cells); and iii) decrease in .DELTA.F/F.sub.m'=(F.sub.m'-F.sub.t)/F.sub.m' (calculated photochemical activity of photosystem II (PSII) signaling full reduction of plastoquinone pool between PSII and PSI, which indicates start of anaerobic conditions that induces synthesis of hydrogenase enzyme for subsequent H.sub.2 production that signal oxidation of plastoquinone pool asmain factor to regulate H.sub.2 under sulfur depletion.

Seibert, Michael (Lakewood, CO); Makarova, Valeriya (Golden, CO); Tsygankov, Anatoly A. (Pushchino, RU); Rubin, Andrew B. (Moscow, RU)

2007-06-12T23:59:59.000Z

499

Abstract--A low noise optical sensor and biocompatible microscale optical filters for integrated fluorescence sensors  

E-Print Network [OSTI]

Abstract--A low noise optical sensor and biocompatible microscale optical filters for integrated fluorescence sensors were developed and tested. The sensor was fabricated in a 0.5 µm CMOS process. The measured reset noise of the sensor is reduced by a factor of 10 compared to conventional active pixel

Maryland at College Park, University of

500

Video-Rate Scanning Two-Photon Excitation Fluorescence Microscopy and Ratio Imaging with Cameleons  

E-Print Network [OSTI]

Video-Rate Scanning Two-Photon Excitation Fluorescence Microscopy and Ratio Imaging with Cameleons ABSTRACT A video-rate (30 frames/s) scanning two-photon excitation microscope has been successfully tested 690 to 1050 nm, prechirper optics for laser pulse-width compression, resonant galvanometer for video

Tsien, Roger Y.