Powered by Deep Web Technologies
Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Electric Transmission System Workshop  

Broader source: Energy.gov (indexed) [DOE]

Lauren Azar Lauren Azar Senior Advisor to Secretary Chu November 2, 2012 Electric Transmission System Workshop We all have "visions," in one form or another: * Corporations call them strategic plans * RTOs ... transmission expansion plans or Order 1000 plans * State PUCs ... integrated resource plans * Employees ... career goals Visions for the Future Artist: Paolo Frattesi Artist: Paolo Frattesi Uncertainty = changing industry Changes in technology, threats and policies Can we make decisions in the face of change? .......How can we not? Can we agree on several key design attributes for the future grid? Taking Action in the Face of Uncertainty Step 1: Establish common ground on key design attributes GTT's Proposed Key Design Attributes:

2

DOE Electricity Transmission System Workshop  

Broader source: Energy.gov (indexed) [DOE]

TRANSMISSION SYSTEM WORKSHOP TRANSMISSION SYSTEM WORKSHOP Mapping Challenges and Opportunities to Help Guide DOE R&D Investments over the Next Five Years DoubleTree Crystal City, 300 Army Navy Drive, Arlington, VA November 1-2, 2012 AGENDA Thursday, November 1, 2012 8:00-8:10 Welcome and Kickoff David Sandalow, Acting Undersecretary of Energy 8:10-8:30 Introduction to the Grid Tech Team (GTT), Vision, and Framework Distribution Workshop Summary Dr. Anjan Bose, Grid Tech Team Lead 8:30-8:50 OE Vision, Activities, and Issues Patricia A. Hoffman, Assistant Secretary for the Office of Electricity Delivery and Energy Reliability (OE) 8:50-9:10 EERE Vision, Activities, and Issues Dr. David Danielson, Assistant Secretary for the Office of Energy Efficiency and Renewable Energy (EERE)

3

DOE Transmission System Integration Workshop  

Broader source: Energy.gov (indexed) [DOE]

Heyeck, AEP, Sr. Vice President, Transmission Heyeck, AEP, Sr. Vice President, Transmission and Chair, EPRI Power Delivery & Utilization Sector Council November 01-02, 2012 DoubleTree Hotel, Crystal City Washington D.C. DOE Transmission System Integration Workshop 2 © 2012 Electric Power Research Institute, Inc. All rights reserved. Near-Zero Emissions Long-Term Operations Renewable Integration Water Management Electric Vehicles Demand Response & Efficiency Renewable Energy Energy Storage Sensors & Control Cyber Security Supply = Demand The Power System Supply to Demand Requires a full portfolio of innovative technologies. Tomorrow's Power System One size does not fit all 3 © 2012 Electric Power Research Institute, Inc. All rights reserved. Grid Transformation to Ensure Reliability, Efficiency, Resiliency and Security

4

Transmission Workshop  

Broader source: Energy.gov (indexed) [DOE]

WORKSHOP WORKSHOP DOUBLETREE CRYSTAL CITY NOVEMBER 1-2, 2012 Anjan Bose, Grid Tech Team U.S. Department of Energy DOE Grid Tech Team (GTT)  The Grid Tech Team (GTT), established by the Office of the Undersecretary of Energy, was tasked with coordinating grid-related activities across the Department and accelerating modernization of the electric power system.  Currently, the GTT comprise of representatives from OE, EERE, ARPA-E, Fossil Energy, Science, Policy and International Affairs, CFO, and the Office of the Secretary of Energy. Vision of the Future Grid A seamless, cost-effective electricity system, from generation to end- use, capable of meeting all clean energy demands and capacity requirements, while allowing consumer participation and electricity

5

Electricity Transmission System Workshop: EERE Issues and Opportunities  

Broader source: Energy.gov (indexed) [DOE]

Electricity Transmission System Electricity Transmission System Workshop: EERE Issues and Opportunities November 1, 2012 Dr. David Danielson Assistant Secretary for the Office of Energy Efficiency and Renewable Energy eere.energy.gov "If you can't solve a problem, expand it." - Dwight D. Eisenhower eere.energy.gov eere.energy.gov Stationary Energy Demand Transport Energy Supply Deploy Clean Electricity Deploy Alternative Hydrocarbon Fuels Modernize the Grid Electrify the Fleet Increase Building and Industrial Efficiency Increase Vehicle Efficiency Source: DOE ,Quadrennial Technology Review, September 2011 eere.energy.gov Rapid Growth in Renewable Electricity Since 2008, the U.S. has doubled renewable energy generation from wind, solar, and

6

Registration Contact List: Electricity Transmission System Workshop  

Broader source: Energy.gov (indexed) [DOE]

11/2/2012 11/2/2012 First Name Last Name Title Company Address1 Address2 City State/Province Zip Country Work Phone Sandy Aivaliotis , Valley Group, a Nexans 3A Trowbridge Drive Bethel CT 6801 United States 416-648-4382 Robert Anders Management U.S. Department of Energy / EERE Rm 6A-067 1000 Independence Ave., SW Washington DC 20585 United States 202-586-4716 Phillip Anderson g g Project Leader Idaho Power 1221 W. Idaho St. Boise ID 83702 United States 208-484-2024 Mihai Anitescu Dr. Argonne National Laboratory 9700 S Cas Avenue Argonne IL 60439 United States 16302524172 Sam Baldwin Officer USDOE/EERE 1000 Independence Ave., SW Washington DC 20585 United States 202-586-0927 Thomas Baldwin Energy Lead Idaho National Laboratory P.O. Box 1655 Idaho Falls ID 83415-3810 United States 208-526-1864 Venkat Banunarayanan g Transmission Department of Energy

7

Transmission Workshop | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

DOE Grid Tech Team » Activities/Outreach » GTT DOE Grid Tech Team » Activities/Outreach » GTT Activities » Transmission Workshop Transmission Workshop Transmission Workshop GTT Transmission Workshop - November 1-2, 2012 On November 1-2, 2012, the GTT presented a workshop on grid integration on the transmission system at the DoubleTree Crystal City near Washington, DC. A draft of the DOE Action Plan Addressing the Electricity Transmission System was discussed during the workshop, which addressed the challenges and opportunities presented by the integration of 21st century energy technologies into the electricity transmission system. Parallel sessions addressed the challenges and opportunities of modernizing the grid and drilled down into key technology areas associated with each of these: System visibility: what advances are needed to "see" the state of

8

Electricity Distribution System Workshop  

Broader source: Energy.gov (indexed) [DOE]

Discussion Summary Discussion Summary Electricity Transmission System Workshop 1 Grid Tech Team Discussion Summary Electricity Transmission System Workshop 2 Table of Contents INTRODUCTION ............................................................................................................................................. 3 EXECUTIVE SUMMARY .................................................................................................................................. 4 Process ...................................................................................................................................................... 4 Synthesized Challenges ............................................................................................................................. 5

9

National Electric Transmission Congestion Study Workshops | Department...  

Broader source: Energy.gov (indexed) [DOE]

National Electric Transmission Congestion Study Workshops National Electric Transmission Congestion Study Workshops DOE hosted four regional pre-study workshops to receive input...

10

Hydrogen Transmission and Distribution Workshop  

Broader source: Energy.gov [DOE]

Proceedings from the Hydrogen Transmission and Distribution Workshop held February 25-26, 2014, in Golden, Colorado. The objective was to discuss and share information on the research, development, and demonstration needs and challenges for low-cost, effective hydrogen transmission and distribution from centralized production facilities to the point of use.

11

2009 National Electric Transmission Congestion Study - Hartford Workshop |  

Broader source: Energy.gov (indexed) [DOE]

2009 National Electric Transmission Congestion Study - Hartford 2009 National Electric Transmission Congestion Study - Hartford Workshop 2009 National Electric Transmission Congestion Study - Hartford Workshop On July 9, 2008, DOE hosted a regional pre-study workshop in Hartford, CT to receive input and suggestions concerning the 2009 National Electric Transmission Congestion Study. The agenda, full transcript, and documents submitted for consideration for the 2009 study are available below. 7-09-08 Congestion Workshop Agenda - Hartford, CT.pdf Transcript - 2009 National Electric Transmission Congestion Study Hartford Workshop.pdf Comments of the New York Independent System Operator, submitted at 2009 Congestion Study Hartford workshop_0.pdf Prepared Remarks of Brian Forshaw, Connecticut Municipal Electric Energy Cooperative, submitted at 2009 Congestion Study Hartford workshop_0.pdf

12

GTT 2012 Transmission Workshop - Documents | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Transmission Workshop - Documents Transmission Workshop - Documents GTT 2012 Transmission Workshop - Documents Use the links below to download documents from the GTT's Transmission Workshop, held November 1-2, 2012 Agenda Roster of Attendees Presentation - Overview - Anjan Bose, DOE Presentation - EERE Issues and Opportunities - David Danielson, DOE Presentation - Vision for the Future - Lauren Azar, DOE Presentation - Tomorrow's Power System - Michael Heyeck, EPRI Presentation - FERC Overview - Cheryl LaFleur, FERC Presentation - ISO/RTO Challenges and Opportunities - Carl Monroe, Southwest Power Pool Product - Future Vision & Grid Challenges: Summary Results of Breakout Group Discussions Product - Opportunities to Overcome Key Challenges: Summary Results of Breakout Group Discussions Product - Final Discussion Summary Report

13

National Electric Transmission Congestion Study- Portland Workshop  

Broader source: Energy.gov [DOE]

On December 13, 2011, DOE hosted a regional pre-study workshop in Portland, OR to receive input and suggestions concerning the National Electric Transmission Congestion Study. The workshop flyer, agenda, presentations, and full transcript are available below.

14

2009 National Electric Transmission Congestion Study - Chicago Workshop |  

Broader source: Energy.gov (indexed) [DOE]

Chicago Chicago Workshop 2009 National Electric Transmission Congestion Study - Chicago Workshop On September 17, 2008, DOE hosted a regional pre-study workshop in Chicago, IL to receive input and suggestions concerning the 2009 National Electric Transmission Congestion Study. The agenda, full transcript, and documents submitted for consideration for the 2009 study are available below. 9-17-08 Congestion Workshop Agenda - Chicago, IL.pdf Transcript - 2009 National Electric Transmission Congestion Study Chicago Workshop.pdf Statement of Michael J. Kormos, PJM Interconnection, submitted at 2009 Congestion Study Chicago workshop.pdf More Documents & Publications Blackout 2003: Electric System Working Group Technical Conference - Comments and Recommendations 2009 National Electric Transmission Congestion Study - San Francisco

15

2009 National Electric Transmission Congestion Study - Atlanta Workshop |  

Broader source: Energy.gov (indexed) [DOE]

2009 National Electric Transmission Congestion Study - Atlanta 2009 National Electric Transmission Congestion Study - Atlanta Workshop 2009 National Electric Transmission Congestion Study - Atlanta Workshop On July 29, 2008, DOE hosted a regional pre-study workshop in Atlanta, GA to receive input and suggestions concerning the 2009 National Electric Transmission Congestion Study. The agenda and full transcript are available below. 7-29-08 Congestion Workshop Agenda - Atlanta, GA.pdf Transcript - 2009 National Electric Transmission Congestion Study Atlanta Workshop.pdf More Documents & Publications 2009 National Electric Transmission Congestion Study - San Francisco Workshop 2012 National Electric Transmission Congestion Study - St. Louis Workshop 2009 National Electric Transmission Congestion Study - Las Vegas Workshop

16

2009 National Electric Transmission Congestion Study - Las Vegas Workshop |  

Broader source: Energy.gov (indexed) [DOE]

2009 National Electric Transmission Congestion Study - Las Vegas 2009 National Electric Transmission Congestion Study - Las Vegas Workshop 2009 National Electric Transmission Congestion Study - Las Vegas Workshop On August 6, 2008, DOE hosted a regional pre-study workshop in Las Vegas, NV to receive input and suggestions concerning the 2009 National Electric Transmission Congestion Study. The agenda and full transcript available below. 8-06-08 Congestion Workshop Agenda - Las Vegas, NV.pdf Transcript - 2009 National Electric Transmission Congestion Study Las Vegas Workshop.pdf More Documents & Publications 2009 National Electric Transmission Congestion Study - San Francisco Workshop 2009 National Electric Transmission Congestion Study - Chicago Workshop 2012 National Electric Transmission Congestion Study - San Diego Workshop

17

Systems Analysis Workshop Purpose  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

National Renewable Energy Laboratory National Renewable Energy Laboratory DOE Hydrogen Program DOE Hydrogen Program Systems Analysis Workshop Systems Analysis Workshop Systems Integration Production Delivery Conversion Application Education Codes & Standards Safety Tech Validation Storage Systems Integration Production Delivery Conversion Application Education Codes & Standards Safety Tech Validation Storage Washington D.C. 28-29 Jul 04 Dale Gardner Systems Integration Operated for the U.S. Department of Energy by Midwest Research Institute * Battelle 2 Systems Analysis Workshop Topics * Meeting Goals * Systems Integration * Roles/Responsibilities of Analysis Participants * Systems Analysis * From this Workshop * Capability Presentations 3 Systems Analysis Workshop Meeting Goals 1) Understand the roles and activities of the DOE Technology Analyst,

18

Hydrogen Delivery Technologies and Systems - Pipeline Transmission...  

Broader source: Energy.gov (indexed) [DOE]

Technologies and Systems Pipeline Transmission of Hydrogen Strategic Initiatives for Hydrogen Delivery Workshop May 7- 8, 2003 U.S. Department of Energy Hydrogen, Fuel Cells,...

19

2009 National Electric Transmission Congestion Study - Chicago Workshop |  

Broader source: Energy.gov (indexed) [DOE]

Chicago Chicago Workshop 2009 National Electric Transmission Congestion Study - Chicago Workshop On September 17, 2008, DOE hosted a regional pre-study workshop in Chicago, IL to receive input and suggestions concerning the 2009 National Electric Transmission Congestion Study. The agenda, full transcript, and documents submitted for consideration for the 2009 study are available below. 9-17-08 Congestion Workshop Agenda - Chicago, IL.pdf Transcript - 2009 National Electric Transmission Congestion Study Chicago Workshop.pdf Statement of Michael J. Kormos, PJM Interconnection, submitted at 2009 Congestion Study Chicago workshop.pdf More Documents & Publications 2009 National Electric Transmission Congestion Study - San Francisco Workshop 2009 National Electric Transmission Congestion Study - Las Vegas Workshop

20

2012 National Electric Transmission Congestion Study Workshops | Department  

Broader source: Energy.gov (indexed) [DOE]

Transmission Planning » Transmission Planning » Congestion Studies » 2012 National Electric Transmission Congestion Study Workshops 2012 National Electric Transmission Congestion Study Workshops DOE hosted four regional pre-study workshops in early December 2011 to receive input and suggestions concerning the 2012 National Electric Transmission Congestion Study. For details, please select a workshop, below. Agendas, presentations, and transcripts are available on the individual workshop pages; please select a workshop from the list below. Note: The November 10, 2011 Federal Register notice incorrectly stated that the four regional workshops would be simulcast over the Internet and that advanced registration for the Webcasts was required. The workshops were not simulcast. The Department requested, but did not require, those who

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

National Electric Transmission Congestion Study 2012 Workshops | Department  

Broader source: Energy.gov (indexed) [DOE]

Transmission Congestion Study 2012 Workshops Transmission Congestion Study 2012 Workshops National Electric Transmission Congestion Study 2012 Workshops DOE will host four regional pre-study workshops in early December 2011 to receive input and suggestions concerning the National Electric Transmission Congestion Study 2012. For details, please see the pdfs, below. Online registration for these workshops is now available. Agendas are available below. Note: The November 10, 2011 Federal Register notice incorrectly stated that the four regional workshops will be simulcast over the Internet and that advanced registration for the Webcasts is required. The workshops will not be simulcast. The Department requests, but does not require, those who are planning to attend the workshops in person to pre-register using the link

22

Regulatory Roadmap Workshop for Federal Bulk Transmission Regulations...  

Open Energy Info (EERE)

Regulatory Roadmapping Pgower's picture Submitted by Pgower(45) Member 7 August, 2014 - 13:19 One-day workshop to review regulatory roadmaps for bulk transmission. Date:...

23

2009 National Electric Transmission Congestion Study Workshops | Department  

Broader source: Energy.gov (indexed) [DOE]

Services » Technology Development » Transmission Planning » Services » Technology Development » Transmission Planning » Congestion Studies » 2009 Congestion Study » 2009 National Electric Transmission Congestion Study Workshops 2009 National Electric Transmission Congestion Study Workshops DOE hosted six regional pre-study workshops in mid-2008 to receive input and suggestions concerning the 2009 National Electric Transmission Congestion Study, including comments on practical metrics for gauging levels and significance of transmission congestion. Each workshop featured a panel of invited speakers to present their views and comments. For details, including agendas, transcripts, and documents submitted for consideration for the 2009 study, please select a workshop, below. June 11, 2008 San Francisco, CA June 18, 2008 Oklahoma City, OK

24

Systems Analysis Workshop Agenda  

Broader source: Energy.gov [DOE]

Agenda from DOE Systems Analysis Workshop held in Washington, D.C. July 28-29, 2004 to discuss and define role of systems analysis in DOE Hydrogen Program.

25

Notice of Technical Workshop in Support of 2009 Electric Transmission  

Broader source: Energy.gov (indexed) [DOE]

Notice of Technical Workshop in Support of 2009 Electric Notice of Technical Workshop in Support of 2009 Electric Transmission Congestion Study: Federal Register Volume 74, No. 32 - Feb. 19, 2009 Notice of Technical Workshop in Support of 2009 Electric Transmission Congestion Study: Federal Register Volume 74, No. 32 - Feb. 19, 2009 The Department of Energy's (DOE) Office of Electricity Delivery and Energy Reliability (OE) conducted a Technical Workshop to receive input from subject matter experts on the historical transmission data in the Western and Eastern Interconnections and on studies of future transmission projections within the two Interconnections. Technical Workshop in Support of 2009 Electric Transmission Congestion Study - Federal Register Vol 74 No. 32 - Feb. 19, 2009.pdf More Documents & Publications

26

Notice of Technical Workshop in Support of 2009 Electric Transmission  

Broader source: Energy.gov (indexed) [DOE]

Notice of Technical Workshop in Support of 2009 Electric Notice of Technical Workshop in Support of 2009 Electric Transmission Congestion Study: Federal Register Volume 74, No. 32 - Feb. 19, 2009 Notice of Technical Workshop in Support of 2009 Electric Transmission Congestion Study: Federal Register Volume 74, No. 32 - Feb. 19, 2009 The Department of Energy's (DOE) Office of Electricity Delivery and Energy Reliability (OE) conducted a Technical Workshop to receive input from subject matter experts on the historical transmission data in the Western and Eastern Interconnections and on studies of future transmission projections within the two Interconnections. Technical Workshop in Support of 2009 Electric Transmission Congestion Study - Federal Register Vol 74 No. 32 - Feb. 19, 2009.pdf More Documents & Publications

27

Electricity Distribution System Workshop  

Broader source: Energy.gov (indexed) [DOE]

Grid Tech Team Grid Tech Team Discussion Summary Electricity Distribution System Workshop 2 Table of Contents INTRODUCTION ............................................................................................................................................. 3 EXECUTIVE SUMMARY .................................................................................................................................. 4 Process ...................................................................................................................................................... 4 Common Themes ...................................................................................................................................... 5 Discussion Topic Tables ............................................................................................................................. 8

28

2012 National Electric Transmission Congestion Study - St. Louis Workshop |  

Broader source: Energy.gov (indexed) [DOE]

St. Louis St. Louis Workshop 2012 National Electric Transmission Congestion Study - St. Louis Workshop On December 8, 2011, DOE hosted a regional pre-study workshop in St. Louis, MO to receive input and suggestions concerning the 2012 National Electric Transmission Congestion Study. The workshop flyer, agenda, presentations, and full transcript are available below. National Electric Transmission Congestion Study 2012 Eastern Workshops 12-08-11 Congestion Workshop Agenda - St Louis (final).pdf Introduction by David Meyer, DOE Presentation by Kevin Gunn, MO PSC.pdf Presentation by Jerry Lein, ND PSC.pdf Presentation by Tom Sloan, KS Legislature.pdf Presentation by Maureen Borkowski, Ameren.pdf Presentation by Laureen L Ross McCalib, Great River Energy.pdf Presentation by Dale Osborn, MISO.pdf

29

2012 National Electric Transmission Congestion Study - Portland Workshop |  

Broader source: Energy.gov (indexed) [DOE]

Portland Portland Workshop 2012 National Electric Transmission Congestion Study - Portland Workshop On December 13, 2011, DOE hosted a regional pre-study workshop in Portland, OR to receive input and suggestions concerning the 2012 National Electric Transmission Congestion Study. The workshop flyer, agenda, presentations, and full transcript are available below. National Electric Transmission Congestion Study 2012 Western Workshops.pdf 12-13-11 CONGESTION WORKSHOP AGENDA - PORTLAND (final).pdf Introduction by David Meyer, DOE .pdf Presentation by Steve Oxley, WY PSC.pdf Presentation by Rich Bayless, NTTG.pdf Presentation by Susan Henderson, Xcel Energy.pdf Presentation by Marv Landauer, ColumbiaGrid.pdf Presentation by Steve Metague, PGE.pdf Presentation by Bradley Nickell, WECC.pdf

30

Remarks for DOE Workshop Regarding Transmission Congestion Study  

Broader source: Energy.gov (indexed) [DOE]

6, 2011 6, 2011 Remarks for DOE Workshop Regarding Transmission Congestion Study Thank you for the opportunity to speak today. I am Ed Finley and I chair the North Carolina Utilities Commission. By way of background, with the exception of a very small portion of the State - the northeast - North Carolina does not participate in a regional transmission organization, or RTO, and our electric utilities remain vertically integrated. North Carolina's electric utilities are required to plan their systems on a least-cost, integrated basis, considering generation and transmission costs, as well as energy efficiency and demand-side management. There is no retail competition in North Carolina. Regulation in North Carolina follows the "command and control" model. The NC Commission must

31

2014 Hydrogen Transmission and Distribution Workshop Summary...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

and other applications). The workshop drew on experts from the industrial gas and energy industries, national laboratories, academia, and the National Institute of...

32

Advanced Supply System Validation Workshop  

Broader source: Energy.gov [DOE]

The Bioenergy Technologies Office (BETO) is hosting the Advanced Supply System Validation Workshop on February 3-4, 2015, in Golden, Colorado. The purpose of the workshop is to bring together a...

33

Advanced Supply System Validation Workshop  

Broader source: Energy.gov [DOE]

The Bioenergy Technologies Office (BETO) is hosting the Advanced Supply System Validation Workshop on February 3-4, 2015, in Golden, Colorado. The purpose of the workshop is to bring together a diverse group of stakeholders to examine, discuss, and validate analysis assumptions used to move beyond current feedstock supply systems designed to support the agriculture and forestry industries. Participants will discuss assumptions relating to volume and transportation logistics, biomass quality, and operational risks. The outcome of the workshop will include a report summarizing the expert opinions shared during the workshop.

34

DOE Electricity Transmission System Workshop  

Energy Savers [EERE]

Forward Looking Panel Presentation & Discussion Moderator: Jay Caspary, Senior Policy Advisor, OE * FERC * ISORTO * Government Utility * Investor-Owned Utility Cheryl LaFleur,...

35

NREL: Energy Systems Integration - Integrated Deployment Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Integrated Deployment Workshop Integrated Deployment Workshop The Energy Systems Integration Facility workshop, Integrated Deployment, was held August 21 - 23, 2012 at the National Renewable Energy Laboratory in Golden, Colorado. Each day of the workshop, which included a tour of the Energy Systems Integration Facility, focused on a different topic: Day 1: Utility-Scale Renewable Integration Day 2: Distribution-Level Integration Day 3: Isolated and Islanded Grid Systems The agenda and presentations from the workshop are below. Agenda Energy Systems Integration Facility Overview ESIF Technology Partnerships Integrated Deployment Model Integrated Deployment and the Energy Systems Integration Facility: Workshop Proceedings Printable Version Energy Systems Integration Home Research & Development

36

Audio Transmission Systems  

Science Journals Connector (OSTI)

Audio transmission systems are the means by which audio signals are routed, processed, and assigned to the desired monitor and recording output channels. In the early days of electrical recording, rarely more ...

John Eargle

1986-01-01T23:59:59.000Z

37

DOE Electricity Distribution System Workshop  

Broader source: Energy.gov (indexed) [DOE]

DISTRIBUTION SYSTEM WORKSHOP DISTRIBUTION SYSTEM WORKSHOP Mapping Challenges and Opportunities to Help Guide DOE R&D Investments over the Next Five Years Sheraton Crystal City, 1800 Jefferson Davis Hwy, Arlington, Virginia September 24-26, 2012 AGENDA Monday, September 24, 2012 1:00-1:30 Welcome and Introduction to the Grid Tech Team (GTT), Vision, and Framework The GTT synchronizes all grid-related activities across the DOE Dr. Anjan Bose, Grid Tech Team Lead 1:30-1:50 OE Vision, Activities, and Issues Patricia A. Hoffman, Assistant Secretary for the Office of Electricity Delivery and Energy Reliability (OE) 1:50-2:10 EERE Vision, Activities, and Issues Dr. David Danielson, Assistant Secretary for the Office of Energy Efficiency and Renewable Energy (EERE) 2:10-2:40 Open Q&A Rich Scheer,

38

Safety System Oversight: 2010 Safety System Oversight Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Safety System Oversight Workshop Safety System Oversight Workshop May 12 - 13, 2010 Las Vegas, NV 2010 Facility Representative and Safety System Oversight Workshops Summary: PDF SSO Steering Committee Meeting Minutes: PDF 2009 Safety System Oversight Annual Award Workshop Agenda: PDF Workshop Presentations: Panel Discussion on the Integration of Facility Representatives and Safety System Oversight Personnel at Site Programs Presentation Panel Highlights Introduction, Goals, and Objectives for SSO Workshop Community Update Demographic Survey Results Introduction of the Safety System Oversight Steering Committee Earl Hughes Presentation Oak Ridge Fire Protection SSO Program Pat Smith, Oak Ridge Office Presentation Commercial Grade Dedication Fran Lemieux, NSTec, Nevada Test Site Presentation

39

Component and System Qualification Workshop Proceedings  

Broader source: Energy.gov [DOE]

Proceedings from the U.S. DOE Hydrogen Component and System Qualification Workshop, held at Sandia National Laboratory in Livermore, CA, on November 4, 2010.

40

Systems Analysis Workshop Welcome & Introductions  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DOE Hydrogen Program DOE Hydrogen Program Systems Analysis Workshop Systems Analysis Workshop Welcome & Introductions Welcome & Introductions Washington D.C. 28-29 Jul 04 Dale Gardner Systems Integration 2 Systems Analysis Workshop Administrative Items Elevators Glass Doors - NREL sign Large Conf Room Elevators Glass Doors - NREL sign Large Conf Room M W Kitchenette Copier/Fax Wanda 202-646-5278/5050 202-646-7790 fax Visitor Offices Restrooms 3 Systems Analysis Workshop Agenda Wednesday, 28 July Welcome & Introduction Dale Gardner 8:00 - 8:10 Role of Analysis in the Hydrogen Program Steve Chalk 8:10 - 8:30 NRC Analysis Recommendations Bob Hirsch 8:30 - 9:00 Systems Analysis Workshop (SAW) Purpose Dale Gardner 9:00 - 9:45 Break 9:45 - 10:00 Capability Briefings Participants 10:00 - 12:00

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Hydrogen Delivery Technologies and Systems - Pipeline Transmission...  

Broader source: Energy.gov (indexed) [DOE]

Hydrogen Delivery Technologies and Systems - Pipeline Transmission of Hydrogen Hydrogen Delivery Technologies and Systems - Pipeline Transmission of Hydrogen Hydrogen Delivery...

42

Technical Workshop: Resilience Metrics for Energy Transmission and Distribution Infrastructure  

Broader source: Energy.gov [DOE]

During this workshop, EPSA invited technical experts from industry, national laboratories, and NGOs to discuss the need for resilience metrics and how they vary by natural gas, liquid fuels and electric grid infrastructures.

43

2015 Wind Energy Systems Engineering Workshop  

Broader source: Energy.gov [DOE]

The National Renewable Energy Laboratory is partnering with the Technical University of Denmarks Department of Wind Energy to co-host the third biennial Wind Energy Systems Engineering Workshop...

44

2014 University Turbine Systems Research Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

University Turbine Systems Research Workshop October 21-24, 2014 Accommodations Union Club Hotel 101 N. Grant Street West Lafayette, IN 47907 The Union Club Hotel will be the...

45

Direct current power transmission systems  

SciTech Connect (OSTI)

This book represents text on HVDC transmission available. It deals with the various aspects of the state of the art in HVDC transmission technology. This book presents many aspects of interactions of AC/DC systems. Modeling and analysis of DC systems are also discussed in detail.

Padiyar, K.R.

1991-01-01T23:59:59.000Z

46

Registration Contact List: Electricity Transmission System Workshop  

Energy Savers [EERE]

NW, Suite 330N Suite 600 Washington DC 20036 United States 202-828-4590 Jay Caspary y Advisor US DOE OE SPP Forrestal Building, 8G-024 1000 Independence Ave, SW Washington DC...

47

Downhole Data Transmission System  

DOE Patents [OSTI]

A system for transmitting data through a string of down-hole components. In accordance with one aspect, the system includes a plurality of downhole components, such as sections of pipe in a drill string. Each downhole component includes a pin end and a box end, with the pin end of one downhole component being adapted to be connected to the box end of another. Each pin end includes external threads and an internal pin face distal to the external threads. Each box end includes an internal shoulder face with internal threads distal to the internal shoulder face. The internal pin face and the internal shoulder face are aligned with and proximate each other when the pin end of the one component is threaded into a box end of the other component.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David (Lehi, UT); Dahlgren, Scott (Provo, UT); Fox, Joe (Spanish Fork, UT)

2004-04-06T23:59:59.000Z

48

Downhole Data Transmission System  

DOE Patents [OSTI]

A system for transmitting data through a string of downhole components. In one aspect, the system includes first and second magnetically conductive, electrically insulating elements at both ends of the component. Each element includes a first U-shaped trough with a bottom, first and second sides and an opening between the two sides. Electrically conducting coils are located in each trough. An electrical conductor connects the coils in each component. In operation, a varying current applied to a first coil in one component generates a varying magnetic field in the first magnetically conductive, electrically insulating element, which varying magnetic field is conducted to and thereby produces a varying magnetic field in the second magnetically conductive, electrically insulating element of a connected component, which magnetic field thereby generates a varying electrical current in the second coil in the connected component.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David (Lehi, UT); Dahlgren, Scott (Provo, UT); Fox, Joe (Spanish Fork, UT)

2003-12-30T23:59:59.000Z

49

Career Map: Power Systems/Transmission Engineer  

Broader source: Energy.gov [DOE]

The Wind Program's Career Map provides job description information for Power Systems and Transmission Engineer positions.

50

Hydrogen Delivery Technologies and Systems - Pipeline Transmission of Hydrogen  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Technologies and Technologies and Systems Pipeline Transmission of Hydrogen Strategic Initiatives for Hydrogen Delivery Workshop May 7- 8, 2003 U.S. Department of Energy ■ Hydrogen, Fuel Cells, and Infrastructure Technologies Program Pipeline Transmission of Hydrogen --- 2 Copyright: Design & Operation Standards Relevant Design and Operating Standards ANSI/ASME B31.8 49 CFR 192 CGA H 2 Pipeline Standard (in development) Pipeline Transmission of Hydrogen --- 3 Copyright: Future H 2 Infrastructure Wind Powered Electrolytic Separation Local Reformers Users Stationary Power Sources Vehicle Fueling Stations Distance from Source to User (Miles) <500 0-5 <2,000 <50 Off-peak Hydroelectric Powered Electrolytic Separation Large Reformers (scale economies) Pipeline Transmission of Hydrogen

51

Workshops  

Broader source: Energy.gov [DOE]

Presentations, video and audio files, and other information related to AMO workshops are available for review.

52

Abstract --Under a context of transmission open access, a methodology to define a common transmission trunk system  

E-Print Network [OSTI]

Terms--Transmission systems, Transmission pricing, Cooperative games, Shapley value, Transmission open

Catholic University of Chile (Universidad Católica de Chile)

53

Systems Analysis Workshop List of Attendees  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Attendee List: Systems Analysis Workshop July 28-29, 2004 Attendee List: Systems Analysis Workshop July 28-29, 2004 DOE HFCIT-Chalk, Steven Steven.Chalk@hq.doe.gov HFCIT-Devlin, Pete * PETER.DEVLIN@ee.doe.gov HFCIT-Milliken, JoAnn JoAnn.Milliken@ee.doe.gov HFCIT-Satyapal, Sunita sunita.satyapal@ee.doe.gov PBA-Patterson, Philip Philip.Patterson@hq.doe.gov PBA-Dowd, Jeff Jeff.Dowd@hq.doe.gov SC-Kung, Harriet * Harriet.Kung@science.doe.gov NE-Henderson, David David.Henderson@hq.doe.gov NE-Sink, Carl carl.sink@nuclear.energy.gov FE-Miller, Lowell LOWELL.MILLER@HQ.DOE.GOV HFCIT-Anderson, Arlene arelene.anderson@ee.doe.gov HFCIT - Gronich, Sig Sig.gronich@ee.doe.gov HFCIT-Epping, Kathi Kathi.epping@ee.doe.gov HFCIT-Lightner, Valri Valri.lightner@ee.doe.gov NREL Systems Integration

54

Workshop title: Transmission and Utility Scale Solar Opportunities "South of Phoenix" (or should we say "in Arizona" if we inc  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Purpose: A stakeholder communication with transmission customers, Tribes, developers, state Purpose: A stakeholder communication with transmission customers, Tribes, developers, state and federal agencies, and utilities about Western Area Power Administration's (Western) Rocky Mountain Region (RMR) and its Transmission Planning and Business Unit. The workshop will provide an overview of Western RMR's transmission planning and services and provide an opportunity for open discussion on overcoming transmission challenges in the region. The workshop will also meet the local transmission planning process requirements for FERC Order 890 as outlined in Western's Open Access Transmission Tariff.

55

Electric Transmission Line Flashover Prediction System  

E-Print Network [OSTI]

Center since 1996 PSERC #12;Power Systems Engineering Research Center Electric Transmission LineElectric Transmission Line Flashover Prediction System Ph.D. Thesis and Final Project Report Power@asu.edu Power Systems Engineering Research Center This is a project report from the Power Systems Engineering

56

Cryogenic Hydrogen Storage Systems Workshop Agenda  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Tuesday, February 15, 2011 - Cryogenic Hydrogen Storage Systems Tuesday, February 15, 2011 - Cryogenic Hydrogen Storage Systems Purpose: Identify R&D needs and technical pathways associated with the continued development and validation of cryo-compressed and cryo-sorption hydrogen storage technologies, highlighting those aspects common to both technologies as well as identifying their unique requirements and issues that should be addressed. 8:30 Welcome/Introductions/Workshop objectives/Recap of previous day Ned Stetson, DOE 9:00 OEM Perspective on Cryogenic H 2 Storage (20 min presentation/20 min discussion) Tobias Brunner, BMW 9:40 Performance Comparison and Cost Review (20 min presentation/20 min discussion) Rajesh Ahluwalia, ANL 10:20 Break (10 minutes) 10:30 Expert Panel Discussion (Members will each have 15 minutes for presentations)

57

Transmission | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Transmission Transmission Transmission Below are resources for Tribes on transmission. Transmission 101 Presentation from the National Council on Electricity Policy's Transmissions Technologies workshop. Includes information on transmission technology, costs, and how to plan the system. Transmission on Tribal Land Basics The Tribal Energy and Environmental Information Clearinghouse provides resources for development on tribal lands. Topics covered include transmission technology basics, potential impacts, law and regulations, and tribal incentives. Transmission Pre-Feasibility Study for Tribes Presentation on the components of a pre-feasibility study including generation location, sizing, and desirability, ability and cost to deliver, capacity versus energy, time of delivery versus peak, request for

58

Workshops  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

NASA Tools for Remote-Sensing in Ecology Research NASA Tools for Remote-Sensing in Ecology Research NASA Tools for Remote-Sensing in Ecology Research Ecological Society of America Annual Meeting WK 2 Pittsburgh, PA - July 31, 2010 Abstract Land remote sensing data can be effectively used by ecologists to understand ecosystem dynamics and to expand site measurements to larger scales. These data can be used to improve our understanding of processes occurring on land and in the lower atmosphere, and play a vital role tin the development of global interactive Earth system models used to predict global change. However, most remote sensing products require special knowledge and software packages to extract information useful for ecologists. This workshop will focus on NASA's MODIS (Moderate Resolution Imaging Spectroradiometer) which views the Earth's surface every 2 to 8

59

2012 National Electric Transmission Congestion Study Workshop … December 13, 2011  

Broader source: Energy.gov (indexed) [DOE]

National Electric Transmission Congestion Study Portland Workshop December 13, 2011 Steve Oxley Deputy Chairman Wyoming Public Service Commission 2 There are two kinds of congestion Type 1: Competitive access to least-cost energy, many sellers vying to serve lucrative markets. Type 2: "Real" physical congestion - characterized by the inability to transmit all available generation. (Type 2a: We can expect the cumulative effect of new EPA rules to make a significant difference on where and how much* congestion we will see. * probably more of each 3 Wyoming is an energy and electron exporting state We are concerned with Type II congestion. We are energy rich, with high quality wind, natural gas and low sulfur coal resources, but . .

60

11.520 Workshop on Geographic Information Systems, Fall 2002  

E-Print Network [OSTI]

This class uses lab exercises and a workshop setting to help students develop a solid understanding of the planning and public management uses of geographic information systems (GIS). The goals are to help students: Acquire ...

Ferreira, Joseph

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

The Electricity Transmission System Future Vision & Grid Challenges  

Broader source: Energy.gov (indexed) [DOE]

Future Vision & Grid Challenges Future Vision & Grid Challenges Summary Results of Breakout Group Discussions Electricity Transmission Workshop Double Tree Crystal City, Arlington, Virginia November 1, 2012 Breakout Group Discussion Overview Future Vision and Grid Challenges Each of the four breakout groups identified the key challenges facing the grid as it integrates all of the various technologies that are (or will be) deployed while ensuring a safe, reliable, and cost-effective system as described in the Future Vision. Utilizing the Grid Tech Team framework, each group identified integration challenges through a systems-based discussion that addressed all of the following topics: * Grid Visibility What challenges in the informational domain (sensors and relays, AMIs, PMUs, end-use energy

62

Safety System Oversight: 2010 Safety System Oversight Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Safety System Oversight Office of Nuclear Safety Home Safety System Oversight Home Annual SSO/FR Workshop DOE Safety Links › ORPS Info › Operating Experience Summary › DOE Lessons Learned › Accident Investigation Program Assessment Tools › SSO CRADS Subject Matter Links General Program Information › Program Mission Statement › SSO Program Description › SSO Annual Award Program › SSO Annual Award › SSO Steering Committee › SSO Program Assessment CRAD SSO Logo Items Site Leads and Steering Committee Archive Facility Representative Contact Us HSS Logo SSO SSO 2012 SAFETY SYSTEM OVERSIGHT ANNUAL AWARD Congratulations to Ronnie Alderson, Nevada Field Office, the Winner of the 2012 DOE Safety System Oversight Annual Award! 2012 NOMINEES: Charles Maggart Idaho Operations Office

63

Optimizing Storages for Transmission System Operation  

Science Journals Connector (OSTI)

Abstract A growing amount of congestions is expected for future operation of electrical transmission grids in Europe. Within this context, storages can be used to assist transmission system operators in daily operation and to avoid costly redispatch measures. In this paper, a research methodology to evaluate impact and interdependencies between market operation of storages and participation in redispatch measures is presented. Furthermore, a methodology for the evaluation of benefits by storages solely administrated by TSO is introduced. The methods are evaluated in a case study for the German electricity system in the year 2020.

Jonas Eickmann; Tim Drees; Jens D. Sprey; Albert Moser

2014-01-01T23:59:59.000Z

64

EIS-0285: Transmission System Vegetation Management Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

February 20, 2003 February 20, 2003 EIS-0285-SA-123: Supplement Analysis Transmission System Vegetation Management Program February 19, 2003 EIS-0285-SA-126: Supplement Analysis Transmission System Vegetation Management Program February 18, 2003 EIS-0285-SA-125: Supplement Analysis Transmission System Vegetation Management Program February 18, 2003 EIS-0285-SA-124: Supplement Analysis Transmission System Vegetation Management Program February 12, 2003 EIS-0285-SA-121: Supplement Analysis Transmission System Vegetation Management Program February 10, 2003 EIS-0285-SA-120: Supplement Analysis Transmission System Vegetation Management Program, Benton County, Washington January 16, 2003 EIS-0285-SA-117: Supplement Analysis Transmission System Vegetation Management Program December 24, 2002

65

EIS-0285: Transmission System Vegetation Management Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

July 19, 2002 July 19, 2002 EIS-0285-SA-96: Supplement Analysis Transmission System Vegetation Management Program, Snohomish District Substations July 19, 2002 EIS-0285-SA-70: Supplement Analysis Transmission System Vegetation Management Program July 9, 2002 EIS-0285-SA-81: Supplement Analysis Transmission System Vegetation Management Program July 1, 2002 EIS-0285-SA-84: Supplement Analysis Transmission System Vegetation Management Program July 1, 2002 EIS-0285-SA-80: Supplement Analysis Transmission System Vegetation Management Program July 1, 2002 EIS-0285-SA-78: Supplement Analysis Transmission System Vegetation Management Program June 21, 2002 EIS-0285-SA-75: Supplement Analysis Transmission System Vegetation Management Program May 31, 2002 EIS-0285-SA-58: Supplement Analysis

66

Steps to Establish a Real-Time Transmission Monitoring System...  

Broader source: Energy.gov (indexed) [DOE]

that must be taken to establish a system to make available to all transmission owners and Regional Transmission Organizations (RTOs) within the Eastern and Western Interconnections...

67

EA-1982: Parker-Davis Transmission System Programmatic Operations...  

Energy Savers [EERE]

on Western's Parker-Davis Transmission System. These actions would occur on existing transmission line and access road rights-of-way, and at substations and maintenance...

68

Methods and systems for micro transmissions  

DOE Patents [OSTI]

Methods and systems for micro transmissions for a micro machine may comprise an input shaft assembly coupled to a micro actuator, an output shaft assembly coupled to a micro shaft, and one or more power conversion elements operable to convert a first type of movement from the micro actuator into a second, disparate type of movement for the micro shaft.

Stalford, Harold L

2014-12-23T23:59:59.000Z

69

Downhole transmission system comprising a coaxial capacitor  

DOE Patents [OSTI]

A transmission system in a downhole component comprises a plurality of data transmission elements. A coaxial cable having an inner conductor and an outer conductor is disposed within a passage in the downhole component such that at least one capacitor is disposed in the passage and having a first terminal coupled to the inner conductor and a second terminal coupled to the outer conductor. Preferably the transmission element comprises an electrically conducting coil. Preferably, within the passage a connector is adapted to electrically connect the inner conductor of the coaxial cable and the lead wire. The coaxial capacitor may be disposed between and in electrically communication with the connector and the passage. In another embodiment a connector is adapted to electrical connect a first and a second portion of the inner conductor of the coaxial cable and a coaxial capacitor is in electrical communication with the connector and the passage.

Hall, David R. (Provo, UT); Pixton, David S. (Lehi, UT); Johnson, Monte L. (Orem, UT); Bartholomew, David B. (Springville, UT); Hall, Jr., H. Tracy (Provo, UT); Rawle, Michael (Springville, UT)

2011-05-24T23:59:59.000Z

70

Data transmission system with distributed microprocessors  

DOE Patents [OSTI]

A data transmission system having a common request line and a special request line in addition to a transmission line. The special request line has priority over the common request line. A plurality of node stations are multi-drop connected to the transmission line. Among the node stations, a supervising station is connected to the special request line and takes precedence over other slave stations to become a master station. The master station collects data from the slave stations. The station connected to the common request line can assign a master control function to any station requesting to be assigned the master control function within a short period of time. Each station has an auto response control circuit. The master station automatically collects data by the auto response controlling circuit independently of the microprocessors of the slave stations.

Nambu, Shigeo (Fuchu, JP)

1985-01-01T23:59:59.000Z

71

Single transmission line data acquisition system  

DOE Patents [OSTI]

A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensors monitor specific process variables and transmit measurement values over the single transmission line to a master station when addressed by the master station. Power for all remote stations (up to 980) is provided by driving the line with constant voltage supplied from the master station and automatically maintained independent of the number of remote stations directly connected to the line. The transmission line can be an RG-62 coaxial cable with lengths up to about 10,000 feet with branches up to 500 feet. The remote stations can be attached randomly along the line. The remote stations can be scanned at rates up to 980 channels/second.

Fasching, George E. (Morgantown, WV)

1984-01-01T23:59:59.000Z

72

Report on the Workshop on Operational Text Classification Systems  

E-Print Network [OSTI]

, user needs, personnel and training, resource demands, maintaining effectiveness over time, and inteReport on the Workshop on Operational Text Classification Systems (OTC-01) David D. Lewis on Operational Text Classification (OTC-01), occurred September 13, 2001 in New Orleans, Louisiana, US. It was co

Sebastiani, Fabrizio

73

The Electricity Transmission System Opportunities to Overcome Key Challenges  

Broader source: Energy.gov (indexed) [DOE]

Opportunities to Overcome Key Challenges Opportunities to Overcome Key Challenges Summary Results of Breakout Group Discussions Electricity Transmission Workshop Double Tree Crystal City, Arlington, Virginia November 2, 2012 Breakout Group Discussion Overview Opportunities to Overcome Key Challenges Each of the four breakout groups prioritized the critical issues facing the grid from the list of synthesized challenges identified in the first breakout session of the workshop. Focusing on these top priorities, each group proposed specific R&D activities and initiatives that DOE can pursue to overcome these challenges and address existing gaps. Summary of Synthesized Challenges A. Need improved understanding of the availability, utility, maintenance, exchange, and security of data and associated requirements.

74

Research and Development Strategies for Compressed & Cryo-Hydrogen Storage Systems- Workshop Summary Report  

Broader source: Energy.gov [DOE]

Summary report from the Compressed and Cryo-Hydrogen Storage Systems Workshops held February 14-15, 2011, in Crystal City, Virginia. Report summarizes the discussions that took place in the breakout sessions and describes major findings of the workshops.

75

GTT Tranmission Workshop- Documents  

Broader source: Energy.gov [DOE]

Use the links below to download documents from the GTT Transmission Workshop, held November 1-2, 2012.

76

Request for Travel Funds for Systems Radiation Biology Workshop  

SciTech Connect (OSTI)

The 3rd International Systems Radiation Biology Workshop brought together the major European, US and Japanese research programs on radiation risk as well as selected experts representing systems biological approaches to discuss how the new methodologies could be best exploited for low dose research. A significant part of the workshop was devoted to discussions organised as breakout group sessions. To facilitate discussions number of participants was limited to 60 persons. To achieve the goals of this symposium in this international conference, support from DOE is vital. Hence, this proposal requested support in the amount of $15,000 to cover the travel expenses of international experts and radiation biology scientists from the United States. This supporting mechanism was clearly identified to the selected US participants as a conference support award from the DOE (See attached PDF). The workshop was an outstanding opportunity to strengthen interactions between leading experts in the emerging areas of radiation sciences, and will also provide opportunities for younger scientists to meet with experts and discuss their results. This workshop was designed to endorse active engagement in international collaboration. A major objective of this conference was to effectively communicate research results, in order to ensure that current thinking reflects sound science of radiation biology. Further, this international event addressed the use and success of scientific initiatives in radiation biology for policymakers, standard-setters, and the general public.

Barcellos-Hoff, Mary Helen [NYU School of Medicine

2014-03-22T23:59:59.000Z

77

NETL Publications: 2011 University Turbine Systems Research Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2011 University Turbine Systems Research Workshop 2011 University Turbine Systems Research Workshop October 25-27, 2011 PRESENTATIONS Tuesday, October 25, 2011 H2 Turbine Development for IGCC with CCS: Project Overviews and Technical Issues [PDF-1.12MB] Susan Scofield, Siemens Energy, Inc. GE Energy's DOE Advanced IGCC/Hydrogen Gas Turbine Program [PDF-1.16MB] Roger Schonewald, GE Energy DOE FE Hydrogen Turbine Program Overview [PDF-1.66MB] Richard Dennis, U.S. Department of Energy, National Energy Technology Laboratory Natural Gas Combined Cycle Power Generation [PDF-1.56MB] Robert Steele, Electric Power Research Institute Overview of Gas Turbine R&D at The Ohio State University [PDF-6.02MB] Meyer (Mike) Benzakein, Director of The Ohio State University's Center for Propulsion and Power An Experimental and Chemical Kinetics Study of the Combustion of Syngas and High Hydrogen Content Fuels [PDF-1.61MB]

78

Research and Development Strategies for Compressed & Cryo-Hydrogen Storage Systems - Workshop Summary Report  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and Development and Development Strategies for Compressed & Cryo-Hydrogen Storage Systems Workshop Summary Report Prepared by: Fuel Cell Technologies Program Compressed & Cryo-Hydrogen Storage Systems Workshops February 14-15, 2011 Crystal City, Virginia Compressed and Cryo-Hydrogen Storage Systems Workshop Summary Report 2 Research and Development Strategies for Compressed & Cryo- Hydrogen Storage Systems Summary: On February 14-15, 2011, the Systems Integration group of the National Renewable Energy Laboratory, in conjunction with the Hydrogen Storage team of the EERE Fuel Cell Technologies Program, hosted two days of workshops on compressed and cryo- hydrogen storage systems in Crystal City, VA. The overarching objective was to

79

GTO thyristor applications for HVDC transmission systems  

SciTech Connect (OSTI)

The development of a large capacity gate turn off thyristor (GTO) has made it possible to manufacture self-commutated convertors employing GTO for power applications. In this paper, conceptual designs for convertor station equipment for a HVDC transmission system employing current as well as voltage source type GTO convertors (simply referred to as VSTGC and CSTGC) are presented. The study result indicates that the VSTGC is preferable over the CSTGC. Also presented in this paper is a preliminary economic comparison between two HVDC system alternatives for applying power to a weak ac system, one employing a self-commutated GTO convertor and the other employing a combination of line-commutated convertor and a synchronous condenser. The result indicates that the two HVDC convertor station alternatives cost about the same.

Yamada, H.; Sampei, M. (Electric Power Development Co. Ltd., Tokyo (Japan)); Kashiwazaki, H.; Tanaka, C. (Hitachi Ltd., Tokyo (Japan)); Takahashi, T.; Horivchi, T. (Toshiba Corp., Tokyo (JP))

1990-07-01T23:59:59.000Z

80

DOE Action Plan Addressing the Electricity Transmission System  

Broader source: Energy.gov (indexed) [DOE]

U.S. DEPARTMENT OF ENERGY U.S. DEPARTMENT OF ENERGY ACTION PLAN ADDRESSING THE ELECTRICITY TRANSMISSION SYSTEM ~DRAFT~ DOE Action Plan Addressing the Electricity Transmission System 1 Table of Contents * INTRODUCTION ................................................................................................................... 2 The Grid Tech Team ...................................................................................................... 2 Focus on Transmission .................................................................................................. 3 Roadmap Goals ............................................................................................................. 4 * PROCESS OVERVIEW ........................................................................................................... 5

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Multi-transmission-line-beam interactive system  

SciTech Connect (OSTI)

We construct here a Lagrangian field formulation for a system consisting of an electron beam interacting with a slow-wave structure modeled by a possibly non-uniform multiple transmission line (MTL). In the case of a single line we recover the linear model of a traveling wave tube due to J. R. Pierce. Since a properly chosen MTL can approximate a real waveguide structure with any desired accuracy, the proposed model can be used in particular for design optimization. Furthermore, the Lagrangian formulation provides: (i) a clear identification of the mathematical source of amplification, (ii) exact expressions for the conserved energy and its flux distributions obtained from the Noether theorem. In the case of uniform MTLs we carry out an exhaustive analysis of eigenmodes and find sharp conditions on the parameters of the system to provide for amplifying regimes.

Figotin, Alexander; Reyes, Guillermo [Department of Mathematics, University of California at Irvine, Irvine, California 92697-3875 (United States)] [Department of Mathematics, University of California at Irvine, Irvine, California 92697-3875 (United States)

2013-11-15T23:59:59.000Z

82

Multi-transmission-line-beam interactive system  

E-Print Network [OSTI]

We construct here a Lagrangian field formulation for a system consisting of an electron beam interacting with a slow-wave structure modeled by a possibly non-uniform multiple transmission line (MTL). In the case of a single line we recover the linear model of a traveling wave tube (TWT) due to J.R. Pierce. Since a properly chosen MTL can approximate a real waveguide structure with any desired accuracy, the proposed model can be used in particular for design optimization. Furthermore, the Lagrangian formulation provides for: (i) a clear identification of the mathematical source of amplification, (ii) exact expressions for the conserved energy and its flux distributions obtained from the Noether theorem. In the case of uniform MTLs we carry out an exhaustive analysis of eigenmodes and find sharp conditions on the parameters of the system to provide for amplifying regimes.

Alexander Figotin; Guillermo Reyes

2013-04-19T23:59:59.000Z

83

U.S. Department of Energy Hydrogen Component and System Qualification Workshop- Presentations  

Broader source: Energy.gov [DOE]

These presentations were given at the U.S. Department of Energy Hydrogen Component and System Qualification Workshop held November 4, 2010 in Livermore, CA.

84

Category:Smart Grid Projects - Electric Transmission Systems | Open Energy  

Open Energy Info (EERE)

Transmission Systems category. Transmission Systems category. Pages in category "Smart Grid Projects - Electric Transmission Systems" The following 10 pages are in this category, out of 10 total. A American Transmission Company LLC II Smart Grid Project American Transmission Company LLC Smart Grid Project D Duke Energy Carolinas, LLC Smart Grid Project E Entergy Services, Inc. Smart Grid Project I ISO New England, Incorporated Smart Grid Project M Midwest Energy Inc. Smart Grid Project Midwest Independent Transmission System Operator Smart Grid Project N New York Independent System Operator, Inc. Smart Grid Project P PJM Interconnection, LLC Smart Grid Project W Western Electricity Coordinating Council Smart Grid Project Retrieved from "http://en.openei.org/w/index.php?title=Category:Smart_Grid_Projects_-_Electric_Transmission_Systems&oldid=214227

85

Workshop: Systems Integration Vision Challenges and Opportunities  

Broader source: Energy.gov [DOE]

Even after achieving the SunShot Initiatives cost targets for solar energy, successful systems integration will remain as the key barrier to enable significantly higher levels of penetration and...

86

Workshop: Systems Integration Vision Challenges and Opportunities...  

Broader source: Energy.gov (indexed) [DOE]

and Opportunities May 22, 2014 2:30PM to 5:30PM PDT Pacific A Even after achieving the SunShot Initiative's cost targets for solar energy, successful systems integration will...

87

Second IEEE Workshop on Agile Cooperative Process-Aware Information Systems (ProGility 2007) -Workshop Report  

E-Print Network [OSTI]

Second IEEE Workshop on Agile Cooperative Process-Aware Information Systems (ProGility 2007 an interest in agile cooperative process-aware information systems. The vision is to be able to rapidly im with each other in networks that are dynamic, flex- ible, ad-hoc, and adaptive. Thus enterprises are develop

Ulm, Universität

88

Boost type PWM HVDC transmission system  

SciTech Connect (OSTI)

This paper reports that conventional HVdc is built around the mercury arc rectifier or the thyristor which requires line commutation. The advances of fast, high power GTO's and future devices such as MCT's with turn off capabilities, are bringing PWM techniques within the range of HVdc applications. By combining PWM techniques to the boost type bridge topology, one has an alternate system of HVdc Transmission. On the ac side, the converter station has active controls over: the voltage amplitude, the voltage angle and the frequency. On the dc side, parallel connections facilitate multi-terminal load sharing by simple local controls so that redundant communication channels are not required. Bidirectional power through each station is accomplished by the reversal of the direction of dc current flow. These claims have been substantiated by experimental results from laboratory size multi-terminal models.

Ooi, B.T.; Wang, X. (McGill Univ., Montreal, PQ (Canada). Dept. of Electrical Engineering)

1991-10-01T23:59:59.000Z

89

Heavy Vehicle Essential Power Systems Workshop  

SciTech Connect (OSTI)

Essential power is a crosscutting technology area that addresses the efficient and practical management of electrical and thermal requirements on trucks. Essential Power Systems: any function on the truck, that is not currently involved in moving the truck, and requires electrical or mechanical energy; Truck Lights; Hotel Loads (HVAC, computers, appliances, lighting, entertainment systems); Pumps, starter, compressor, fans, trailer refrigeration; Engine and fuel heating; and Operation of power lifts and pumps for bulk fluid transfer. Transition from ''belt and gear driven'' to auxiliary power generation of electricity - ''Truck Electrification'' 42 volts, DC and/ or AC; All electrically driven auxiliaries; Power on demand - manage electrical loads; Benefits include: increased fuel efficiency, reduced emission both when truck is idling and moving down the road.

Susan Rogers

2001-12-12T23:59:59.000Z

90

Proceedings of the National Renewable Energy Laboratory Wind Energy Systems Engineering Workshop  

SciTech Connect (OSTI)

The second National Renewable Energy Laboratory (NREL) Wind Energy Systems Engineering Workshop was held in Broomfield, Colorado, from January 29 to February 1, 2013. The event included a day-and-a-half workshop exploring a wide variety of topics related to system modeling and design of wind turbines and plants. Following the workshop, 2 days of tutorials were held at NREL, showcasing software developed at Sandia National Laboratories, the National Aeronautics and Space Administration's Glenn Laboratories, and NREL. This document provides a brief summary of the various workshop activities and includes a review of the content and evaluation results from attendees.

Dykes, K.

2014-12-01T23:59:59.000Z

91

GRC Workshop: The Power of the National Geothermal Data System | Department  

Broader source: Energy.gov (indexed) [DOE]

GRC Workshop: The Power of the National Geothermal Data System GRC Workshop: The Power of the National Geothermal Data System GRC Workshop: The Power of the National Geothermal Data System October 2, 2013 (All day) Flyer for the National Geothermal Data System workshop at the Geothermal Resources Council Annual Meeting on October 2, 2013 in Las Vegas. Drilling Down: How Legacy and New Research Data Can Advance Geothermal Development-The Power of the National Geothermal Data System (NGDS) A workshop at the Geothermal Resources Council Annual Meeting in Las Vegas, Nevada Abstract: The National Geothermal Data System's (NGDS) launch in 2014 will provide open access to millions of datasets, sharing technical geothermal-relevant data across the geosciences to propel geothermal development and production forward. By aggregating findings from the Energy Department's RD&D projects

92

Performance Metrics for Intelligent Systems Workshop March 20-22, 2012  

E-Print Network [OSTI]

) - Smart Grid - Space Robotics - Medical & Healthcare Systems and Devices The Proceedings of Per) Workshop will be the eleventh in a series of workshops dedicated to defining measures and methodologies of evaluating performance of intelligent systems. Started in 2000, the PerMIS series focuses on applications

Perkins, Richard A.

93

Hydrogen Delivery Technologies and Systems- Pipeline Transmission of Hydrogen  

Broader source: Energy.gov [DOE]

Hydrogen Delivery Technologies and Systems - Pipeline Transmission of Hydrogen. Design and operations standards and materials for hydrogen and natural gas pipelines.

94

Definition: Transmission Line Monitoring System | Open Energy Information  

Open Energy Info (EERE)

Monitoring System Monitoring System Jump to: navigation, search Dictionary.png Transmission Line Monitoring System Hardware, software, including sensors for voltage, current, temperature, mechanical load, wind speed, or other electrical or environmental parameters, including synchrophasors. These systems are designed to provide precise information that determine the operating conditions and ratings of transmission lines. Such a system can monitor line conditions and alert grid operators of trouble.[1] Related Terms transmission lines, transmission line References ↑ https://www.smartgrid.gov/category/technology/transmission_line_monitoring_system [[Ca LikeLike UnlikeLike You like this.Sign Up to see what your friends like. tegory: Smart Grid Definitionssmart grid,smart grid, |Template:BASEPAGENAME]]smart grid,smart grid,

95

PROCEEDINGS OF THE WORKSHOP ON LHC INTERACTION REGION CORRECTION SYSTEMS  

SciTech Connect (OSTI)

The Workshop on LHC Interaction Region Correction Systems was held at Brookhaven National Laboratory, Upton, New York, on 6 and 7 May 1999. It was attended by 25 participants from 5 institutions. The performance of the Large Hadron Collider (LHC) at collision energy is limited by the field quality of the interaction region quadrupoles and dipoles. In three sessions the workshop addressed the field quality of the these magnets, reviewed the principles and efficiency of global and local correction schemes and finalized a corrector layout. The session on Field Quality Issues, chaired by J. Strait (FNAL), discussed the progress made by KEK and FNAL in achieving the best possible field quality in the interaction region quadrupoles. Results of simulation studies were presented that assess the effects of magnetic field errors with simulation studies. Attention was given to the uncertainties in predicting and measuring field errors. The session on Global Correction, chaired by J.-P. Koutchouk (CERN), considered methods of reducing the nonlinear detuning or resonance driving terms in the accelerator one-turn map by either sorting or correcting. The session also discussed the crossing angle dependence of the dynamic aperture and operational experience from LEP. The session on Local Correction, chaired by T. Taylor (CERN), discussed the location, strength and effectiveness of multipole correctors in the interaction regions for both proton and heavy ion operation. Discussions were based on technical feasibility considerations and dynamic aperture requirements. The work on linear corrections in the interaction regions was reviewed.

FISCHER,W.; WEI,J.

1999-09-02T23:59:59.000Z

96

American Transmission Systems Inc | Open Energy Information  

Open Energy Info (EERE)

for 2010 - File1a1 EIA Form 861 Data Utility Id 56162 Utility Location Yes Ownership T NERC Location RFC NERC RFC Yes ISO MISO Yes Activity Transmission Yes This article is a...

97

Radio frequency communication system utilizing radiating transmission lines  

DOE Patents [OSTI]

A radio communication system for use in tunnels, mines, buildings or other shielded locations in which a pair of radiating transmission lines (30), (31) extend through such location in spaced coextensive relation to each other. Each transmission line (30), (31) has at least one unidirectional amplifier (32), (33) interposed therein with the sense of the unidirectional amplifier (32) of one transmission line (30) being opposite to the sense of the unidirectional amplifier (33) of the other transmission line (31). Each of the amplifiers (32), (33) has a gain which is less than the coupling loss between the transmission lines (30), (31). Two or more mobile transceivers (35) in the location served by the system are coupled to the transmission lines (30), (31) by electromagnetic wave propagation in space in order to communicate directly with each other at a given radio frequency within the frequency range of the system.

Struven, Warren C. (San Carlos, CA)

1984-01-01T23:59:59.000Z

98

1 Introduction Danish transmission system operator  

E-Print Network [OSTI]

a new 400 kV transmission line between the cities Aarhus and Aalborg, app 90 km. This line at the 150 kV transmission level and intended to be used at 400 kV more than just for this line. Can of the dynamic behavior of a shunt reactor compensated 400 kV combined cable/overhead line. This is accomplished

Bak, Claus Leth

99

The Economic Case for Bulk Energy Storage in Transmission Systems  

E-Print Network [OSTI]

The Economic Case for Bulk Energy Storage in Transmission Systems with High Percentages to Engineer the Future Electric Energy System #12;#12;The Economic Case for Bulk Energy Storage Economic Case for Bulk Energy Storage in Transmission Sys- tems with High Percentages of Renewable

100

1 BPP II Workshop May 1-3 2001 Ion Cyclotron Systems for Burning Plasma Experiments*  

E-Print Network [OSTI]

Laboratory managed by UT-Battelle. #12;2 BPP II Workshop May 1-3 2001 Introduction Ion cyclotron heating Information in this section is from the ITER Design Description Document for the Ion Cyclotron Heating1 BPP II Workshop May 1-3 2001 Ion Cyclotron Systems for Burning Plasma Experiments* D. A

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Distribution Workshop  

Broader source: Energy.gov [DOE]

On September 24-26, 2012, the GTT presented a workshop on grid integration on the distribution system at the Sheraton Crystal City near Washington, DC.

102

EIS-0285: Transmission System Vegetation Management Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

285: Transmission System Vegetation Management Program 285: Transmission System Vegetation Management Program EIS-0285: Transmission System Vegetation Management Program SUMMARY Bonneville Power Administration (Bonneville) is responsible for maintaining a network of 24,000 kilometers (km) or 15,000 miles (mi.) of electric transmission lines and 350 substations. This electric transmission system operates in seven states of the Pacific Northwest. (See Figure I-1). The seven states offer a great diversity of vegetation. This vegetation can interfere with electric power flow, pose safety problems for us and neighboring members of the public, and interfere with our ability to maintain these facilities. We need to keep vegetation a safe distance away from our electric power facilities and control noxious weeds at our

103

Safety of Gas Transmission and Distribution Systems (Maine) | Department of  

Broader source: Energy.gov (indexed) [DOE]

Safety of Gas Transmission and Distribution Systems (Maine) Safety of Gas Transmission and Distribution Systems (Maine) Safety of Gas Transmission and Distribution Systems (Maine) < Back Eligibility Agricultural Commercial Construction Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Program Info State Maine Program Type Safety and Operational Guidelines Provider Public Utilities Commission These regulations describe requirements for the participation of natural gas utilities in the Underground Utility Damage Prevention Program,

104

1 Introduction Danish transmission system operator  

E-Print Network [OSTI]

400 kV transmission line between the cities Aarhus and Aalborg, app. 90 km. This line is constructed reactor compensated 400 kV combined cable/overhead line. This is accomplished by means of theoretical-phase autoreclosure ARC in such a combined cable/OHL line. Keywords -- 400 kV cable, single-phase autoreclosure, shunt

Bak, Claus Leth

105

Application for presidential permit OE Docket No. PP-230-4 International Transmission Company: Supplemental Comments of the Midwest Independent Transmission System Operator  

Broader source: Energy.gov [DOE]

Supplemental comments of the Midwest Independent Transmission System Operaton on the application from International Transmission Company to construct, operate, and maintain electric transmission...

106

Power electronics in electric utilities: HVDC power transmission systems  

SciTech Connect (OSTI)

High Voltage Direct Current (HVDC) power transmission systems constitute an important application of power electronics technology. This paper reviews salient aspects of this growing industry. The paper summarizes the history of HVDC transmission and discusses the economic and technical reasons responsible for development of HVDC systems. The paper also describes terminal design and basic configurations of HVDC systems, as well as major equipments of HVDC transmission system. In this regard, the state-of-the-art technology in the equipments constructions are discussed. Finally, the paper reviews future developments in the HVDC transmission systems, including promising technologies, such as multiterminal configurations, Gate Turn-Off (GTO) devices, forced commutation converters, and new advances in control electronics.

Nozari, F.; Patel, H.S.

1988-04-01T23:59:59.000Z

107

Integrated System Transmission and Ancillary Services Rate Calculation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission Rate 10 4.00 MillsKWh (L5 * 1000) 730 hours per month 7 RATE FOR SCHEDULING, SYSTEM CONTROL AND DISPATCH SERVICE FOR 2015 A. Fixed Charge Rate 21.652% (1)...

108

THE PUSH TOWARD GRID REGIONALIZATION IN OPEN ACCESS TRANSMISSION SYSTEMS  

E-Print Network [OSTI]

THE PUSH TOWARD GRID REGIONALIZATION IN OPEN ACCESS TRANSMISSION SYSTEMS ProfessorGeorge Gross Universityof Illinois atUrbana-Champaign USA E-mail:gross@uiuc.edu ExtendedSummary Keywords:RTO, ISO

Gross, George

109

AC transmission system planning choosing lines from a discrete set  

E-Print Network [OSTI]

Transmission system planning (TSP) is a difficult nonlinear optimization problem involving non-convex quadratic terms, as well as discrete variables. We extend prior results for linear relaxations, drawing on a preliminary ...

Gilbertson, Eric W.

2013-04-24T23:59:59.000Z

110

///COUNTER : an artistic system for the transmission of cultural energy  

E-Print Network [OSTI]

My thesis introduces ///COUNTER as an artistic system for the transmission of cultural energy. The underlying concepts of ///COUNTER are derived directly from my work on energy access as developed through the eWheel and ...

Vincent de Paul, Jegan Joyston

2009-01-01T23:59:59.000Z

111

Transmission  

Broader source: Energy.gov (indexed) [DOE]

Transmission Transmission ,... ,...vc- "' ""'\ S I r;. Dr. Jerry Pell, CCM Principal NEP A Document Manager Permitting, Siting, and Analysis (OE-20) Office of Electricity Delivery and Energy Reliability U.S. Department of Energy 1 000 Independence A venue SW Washington, D.C. 20585-0001 Subject: Champlain Hudson Power Express Project Submittal of Amendment Application Dear Dr. Pell: February 28, 2012 On January 25, 2010, Transmission Developers, Inc. ("TDI") submitted on behalf of Champlain Hudson Power Express, Inc. ("CHPEI") an application to the U.S. Department of Energy ("DOE") for a Presidential Permit ("Application) in connection with the Champlain Hudson Power Express project ("Project"). The Application proposed to connect clean sources

112

EV Everywhere Workshop: Traction Drive Systems Breakout Group Report  

Broader source: Energy.gov [DOE]

Presentation given at the EV Everywhere Grand Challenge - Electric Drive (Power Electronics and Electric Machines) Workshop on July 24, 2012 held at the Doubletree O'Hare, Chicago, IL.

113

Wind Mills and Transmission System Interaction.  

E-Print Network [OSTI]

??This thesis report focuses on different kinds of power system disturbances and their impact on voltage profile at the point of wind power connection. The (more)

Akwarandu, John

2006-01-01T23:59:59.000Z

114

High Penetration of Photovoltaic (PV) Systems into the Distribution Grid, Workshop Report, February 24-25, 2009  

SciTech Connect (OSTI)

Outcomes from the EERE Solar Energy Technologies Program workshop on high penetration of photovoltaic (PV) systems into the distribution grid, Feb. 24-25, 2009, Ontario, Calif.

Not Available

2009-06-01T23:59:59.000Z

115

Single transmission line interrogated multiple channel data acquisition system  

DOE Patents [OSTI]

A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensor circuits each monitors a specific process variable and each transmits measurement values over a single transmission line to a master interrogating station when addressed by said master interrogating station. Typically, as many as 330 remote stations may be parallel connected to the transmission line which may exceed 7,000 feet. The interrogation rate is typically 330 stations/second. The master interrogating station samples each station according to a shared, charging transmit-receive cycle. All remote station address signals, all data signals from the remote stations/sensors and all power for all of the remote station/sensors are transmitted via a single continuous terminated coaxial cable. A means is provided for periodically and remotely calibrating all remote sensors for zero and span. A provision is available to remotely disconnect any selected sensor station from the main transmission line.

Fasching, George E. (Morgantown, WV); Keech, Jr., Thomas W. (Morgantown, WV)

1980-01-01T23:59:59.000Z

116

DRAFT Parker-Davis Transmission System  

Office of Environmental Management (EM)

system. 3.13.1.1 Sensitive Receptors Some land uses are considered more sensitive to air pollution than others due to the types of population groups or activities involved....

117

Cryogenics Vision Workshop for High-Temperature Superconducting Electric Power Systems Proceedings  

SciTech Connect (OSTI)

The US Department of Energy's Superconductivity Program for Electric Systems sponsored the Cryogenics Vision Workshop, which was held on July 27, 1999 in Washington, D.C. This workshop was held in conjunction with the Program's Annual Peer Review meeting. Of the 175 people attending the peer review meeting, 31 were selected in advance to participate in the Cryogenics Vision Workshops discussions. The participants represented cryogenic equipment manufactures, industrial gas manufacturers and distributors, component suppliers, electric power equipment manufacturers (Superconductivity Partnership Initiative participants), electric utilities, federal agencies, national laboratories, and consulting firms. Critical factors were discussed that need to be considered in describing the successful future commercialization of cryogenic systems. Such systems will enable the widespread deployment of high-temperature superconducting (HTS) electric power equipment. Potential research, development, and demonstration (RD and D) activities and partnership opportunities for advancing suitable cryogenic systems were also discussed. The workshop agenda can be found in the following section of this report. Facilitated sessions were held to discuss the following specific focus topics: identifying Critical Factors that need to be included in a Cryogenics Vision for HTS Electric Power Systems (From the HTS equipment end-user perspective) identifying R and D Needs and Partnership Roles (From the cryogenic industry perspective) The findings of the facilitated Cryogenics Vision Workshop were then presented in a plenary session of the Annual Peer Review Meeting. Approximately 120 attendees participated in the afternoon plenary session. This large group heard summary reports from the workshop session leaders and then held a wrap-up session to discuss the findings, cross-cutting themes, and next steps. These summary reports are presented in this document. The ideas and suggestions raised during the Workshop will be used by the DOE Superconductivity Program for Electric Systems in preparing subsequent planning and strategy documents such as a Cryogenic Technology Development Roadmap.

Energetics, Inc.

2000-01-01T23:59:59.000Z

118

2012 Facility Representative/Safety System Oversight/Fire Safety Workshop Agenda  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Facility Representative  Safety System Oversight  Fire Safety Facility Representative  Safety System Oversight  Fire Safety Overall Workshop Agenda May 14-18, 2012  Alexis Park Hotel  Las Vegas, Nevada Monday, May 14, 2012 8:00 a.m. - 5:00 p.m. SAF-271, SSO Assessments (Day 1) Zeus B Quality Assurance Overview for FR/SSO Personnel Zeus A 5:00 p.m. - 7:00 p.m. Workshop Registration Zeus Foyer Tuesday, May 15, 2012 8:00 a.m. - 5:00 p.m. Fire Safety Workshop Track Begins (see track agenda) Parthenon 4 SAF-271, SSO Assessments (Day 2) Zeus B . Safety Culture Workshop Zeus A Federal Technical Capability Panel Parthenon 2 5:00 p.m. - 7:00 p.m. Workshop Registration Zeus Foyer Wednesday, May 16, 2012 6:30 a.m. - 7:45 a.m. Workshop Registration Zeus Foyer 8:00 a.m. - 11:30 a.m. FR/SSO Tracks Begin; Plenary session with Fire Safety Track Parthenon 2 & 4

119

Cryogenic System for a High Temperature Superconducting Power Transmission Cable  

SciTech Connect (OSTI)

High-temperature superconducting (HTS) cable systems for power transmission are under development that will use pressurized liquid nitrogen to provide cooling of the cable and termination hardware. Southwire Company and Oak Ridge National Laboratory have been operating a prototype HTS cable system that contains many of the typical components needed for a commercial power transmission application. It is being used to conduct research in the development of components and systems for eventual commercial deployment. The cryogenic system was built by Air Products and Chemicals, Allentown, Pennsylvania, and can circulate up to 0.35 kg/s of liquid nitrogen at temperatures as low as 67 K at pressures of 1 to 10 bars. Sufficient cooling is provided for testing a 5-m-long HTS transmission cable system that includes the terminations required for room temperature electrical connections. Testing of the 5-m HTS transmission cable has been conducted at the design ac conditions of 1250 A and 7.5 kV line to ground. This paper contains a description of the essential features of the HTS cable cryogenic system and performance results obtained during operation of the system. The salient features of the operation that are important in large commercial HTS cable applications will be discussed.

Demko, J.A.; Gouge, M.J.; Hughey, R.L.; Lue, J.W.; Martin, R.; Sinha, U.; Stovall, J.P.

1999-07-12T23:59:59.000Z

120

Data Transmission System For A Downhole Component  

DOE Patents [OSTI]

The invention is a system for transmitting data through a string of downhole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. Each component has a first and second end, with a first communication element located at the first end and a second communication element located at the second end. Each communication element includes a first contact and a second contact. The system also includes a coaxial cable running between the first and second communication elements, the coaxial cable having a conductive tube and a conductive core within it. The system also includes a first and second connector for connecting the first and second communication elements respectively to the coaxial cable. Each connector includes a conductive sleeve, lying concentrically within the conductive tube, which fits around and makes electrical contact with the conductive core. The conductive sleeve is electrically isolated from the conductive tube. The conductive sleeve of the first connector is in electrical contact with the first contact of the first communication element, the conductive sleeve of the second connector is in electrical contact with the first contact of the second communication element, and the conductive tube is in electrical contact with both the second contact of the first communication element and the second contact of the second communication element.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David (Lehi, UT); Dahlgren, Scott (Provo, UT); Sneddon, Cameron (Provo, UT); Fox, Joe (Spanish Fork, UT); Briscoe, Michael (Lehi, UT)

2005-01-18T23:59:59.000Z

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Commutation failures in HVDC transmission systems  

SciTech Connect (OSTI)

This paper provides a formulation for the initiation or onset mechanism of commutation failures in line-commutated thyristor converters, assuming infinite (zero impedance) ac systems. A theoretical development and a parametric analysis is given. Theory validation by simulation and comparison to actual field experience data is also given.

Thio, C.V.; Davies, J.B.; Kent, K.L. [Manitoba Hydro, Winnipeg, Manitoba (Canada)] [Manitoba Hydro, Winnipeg, Manitoba (Canada)

1996-04-01T23:59:59.000Z

122

Transmission Pricing of Distributed Multilateral Energy Transactions to Ensure System Security and Guide Economic Dispatch  

E-Print Network [OSTI]

Transmission Pricing of Distributed Multilateral Energy Transactions to Ensure System Security and Guide Economic Dispatch...

Ilic, Marija; Hsieh, Eric; Remanan, Prasad

2004-06-16T23:59:59.000Z

123

Reliability modeling and evaluation of HVDC power transmission systems  

SciTech Connect (OSTI)

The objective of this paper is to present an improved computational method for evaluating the reliability indices of HVdc transmission systems. The developed models and computational techniques are described. These can be used to simulate the operational practices and characteristics of a system under study efficiently and realistically. This method is based on the failure modes and effects analysis and uses the event tree method and the minimal cut set approach to represent the system's operational behavior and deduce the appropriate system's failure modes. A set of five reliability indices is evaluated for each output node being analyzed together with the probability and frequency of encountering particular regions of system performance levels. The analysis of an assumed HVdc bipolar transmission system is also included.

Dialynas, E.N.; Koskolos, N.C. (National Technical Univ., Athens (Greece). Dept. of Electrical and Computer Engineering)

1994-04-01T23:59:59.000Z

124

Integrating Renewable Energy into the Transmission and Distribution System  

Broader source: Energy.gov (indexed) [DOE]

Integrating Renewable Energy into the Transmission and Distribution Integrating Renewable Energy into the Transmission and Distribution System of the U.S. Virgin Islands Integrating Renewable Energy into the Transmission and Distribution System of the U.S. Virgin Islands This report describes one area in which islands may lead: integrating a high percentage of renewable energy resources into an isolated grid. In addition, it explores the challenges, feasibility, and potential benefits of interconnecting the USVI grids with the much larger Puerto Rican grid. 51294.pdf More Documents & Publications USVI Energy Road Map: Charting the Course to a Clean Energy Future (Brochure), EDIN (Energy Development in Island Nations), U.S. Virgin Islands U.S. Virgin Islands Energy Road Map: Analysis Waste-to-Energy Evaluation: U.S. Virgin Islands

125

3rd Workshop on System-level Virtualization for High Performance Computing (HPCVirt) 2009, Nuremberg, Germany, March 30, 2009  

E-Print Network [OSTI]

3rd Workshop on System-level Virtualization for High Performance Computing (HPCVirt) 2009 for High Performance Computing (HPCVirt) 2009, Nuremberg, Germany, March 30, 2009 Outline · Background work #12;3/193rd Workshop on System-level Virtualization for High Performance Computing (HPCVirt) 2009

Engelmann, Christian

126

Fifth Workshop on Software Engineering for Adaptive and Self-Managing Systems (SEAMS 2010)  

Science Journals Connector (OSTI)

The Software Engineering for Adaptive and Self-managing Systems (SEAMS) workshop has consolidated the interest in the software engineering community on self-adaptive and self-managing systems. SEAMS provides a forum for researchers and practitioners ... Keywords: adaptive software, autonomic computing

Betty H. C. Cheng; Rogrio de Lemos; David Garlan; Holger Giese; Marin Litoiu; Jeff Magee; Hausi A. Mller; Mauro Pezz; Richard Taylor

2010-05-01T23:59:59.000Z

127

Research and Practice in Federated Information Systems Report of the EFIS '2000 International Workshop  

E-Print Network [OSTI]

for federated system integration, and the use of meta- directories in building federations. DetailsResearch and Practice in Federated Information Systems Report of the EFIS '2000 International Workshop W. Hasselbring W.-J. van den Heuvel y G.J. Houben z R.-D. Kutsche x B. Rieger M. Roantree k K

Houben, Geert-Jan

128

Planning considerations for the intermountain HVDC transmission system  

SciTech Connect (OSTI)

Planning of an HVDC transmission system embedded into an existing ac network may require unique control and converter equipment capability in order to satisfy stability requirements of the network. The planning and design of the Intermountain Power Project HVDC transmission system are based on unique control performance features for power transfers during terminal ac faults, rapid power recovery following fault clearing and utilization of exceptionally high transient overload capability of 2 per unit during the post-fault period to maintain system stability. The Department, in its efforts to meet the Western Systems Coordinating Council's (WSCC) reliability criteria, developed and incorporated into its HVDC specifications very rigorous reliability and availability requirements. One objective of this project was to attain the unusually low bipolar converter system outage frequency goal of one outage in five years to achieve a bipole performance rating equivalent to two ac circuits of similar capability. The reliability goals of this project have provided one of the impetus for revisions to the WSCC Reliability Criteria for System Design. The reliability goals and other features adopted for the Intermountain HVDC transmission system are discussed in this paper and study results are included to demonstrate the effectiveness of various controls implemented as stability enhancement techniques.

Lee, R.L.; Beshir, M.J.; Gee, J.H.

1986-01-01T23:59:59.000Z

129

Complex dynamics of blackouts in power transmission systems  

Science Journals Connector (OSTI)

In order to study the complex global dynamics of a series of blackouts in power transmission systems a dynamical model of such a system has been developed. This model includes a simple representation of the dynamical evolution by incorporating the growth of power demand the engineering response to system failures and the upgrade of generator capacity. Two types of blackouts have been identified each having different dynamical properties. One type of blackout involves the loss of load due to transmission lines reaching their load limits but no line outages. The second type of blackout is associated with multiple line outages. The dominance of one type of blackout over the other depends on operational conditions and the proximity of the system to one of its two critical points. The model displays characteristics such as a probability distribution of blackout sizes with power tails similar to that observed in real blackout data from North America.

B. A. Carreras; V. E. Lynch; I. Dobson; D. E. Newman

2004-01-01T23:59:59.000Z

130

2012 Facility Representative/Safety System Oversight/Fire Safety Workshop - Registrants  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Facility Representative / Safety System Oversight Workshop Facility Representative / Safety System Oversight Workshop DOE Fire Safety Workshop Federal Technical Capability Panel (FTCP) Meeting May 14 - 18, 2012, at the Alexis park Resort Hotel, Las Vegas, NV Registrants As of 5/15/2012 Total Number: 218 First Name Last Name Government /Contractor Agency Secretarial Office Site Position Training Course FTCP FS 5/15 FS 5/16 FR/SSO Plenary FR Track SSO Track Fire Safety Training Tour Ron Alderson Government Employee DOE NNSA Nevada SSO SAF-271 No No No Yes No Yes No No Josh Allen Government Employee DOE EM Richland FR No No No No Yes Yes No No No Mark Alsdorf Government Employee DOE HSS Headquarters NTC Safety Training Manager SAF-271 Yes No No Yes No No No No Xavier Aponte Government Employee

131

Call for Student Demos and Posters on Unmanned Aerial Systems AIAA workshop on "Airborne Networks and Communications"  

E-Print Network [OSTI]

Call for Student Demos and Posters on Unmanned Aerial Systems AIAA workshop on "Airborne Networks, this workshop will also include a session on student posters and demonstrations of unmanned aerial vehicles. Undergraduate and graduate students whose posters and demos are selected for presentation will be provided

Namuduri, Kamesh

132

Midwest Independent Transmission System Operator Smart Grid Project | Open  

Open Energy Info (EERE)

Operator Smart Grid Project Operator Smart Grid Project Jump to: navigation, search Project Lead Midwest Independent Transmission System Operator Country United States Headquarters Location Carmel, Indiana Additional Benefit Places Iowa, Illinois, Michigan, Minnesota, Missouri, Montana, North Dakota, Ohio, Pennsylvania, South Dakota, Wisconsin Recovery Act Funding $17,271,738.00 Total Project Value $34,543,476.00 Coverage Area Coverage Map: Midwest Independent Transmission System Operator Smart Grid Project Coordinates 39.978371°, -86.1180435° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

133

Linkage to Previous International PV Module QA Task Force Workshops: Proposal for Rating System  

Broader source: Energy.gov [DOE]

This PowerPoint presentation, focused on humidity, temperature and voltage testing, was originally presented at the NREL 2013 PV Module Reliability Workshop on Feb. 26-27, 2013 in Denver, CO. It summarizes the efforts of previous QA task forces and proposes a QA rating system to differentiate the relative durability of model designs.

134

IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems Corresponding author: P. Leblay  

E-Print Network [OSTI]

3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems Corresponding author: P on the refrigerant side and louver fins on the air side. The flat tubes are grouped within a header, to use the heat exchangers with round tubes, such as charge reduction and higher heat transfer efficiency. But a reduced

Paris-Sud XI, Université de

135

Performance Metrics for Intelligent Systems Workshop March 20-22, 2012  

E-Print Network [OSTI]

will be the eleventh in a series of workshops dedicated to defining measures and methodologies of evaluating) - Intelligent Systems and Robots for Hazardous Environments (e.g. nuclear remediation) - Smart Grid - Space measures to applied problems in commercial, industrial, homeland security, and military applications. Per

Perkins, Richard A.

136

Princeton Power Systems (TRL 5 6 Component)- Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage  

Broader source: Energy.gov [DOE]

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage

137

Request for Comments on the Electric Grid Integration Technical Workshops  

Broader source: Energy.gov (indexed) [DOE]

Request for Comments on the Electric Grid Integration Technical Request for Comments on the Electric Grid Integration Technical Workshops Summaries: Federal Register Notice Volume 78, No. 35 - Feb. 21, 2013 Request for Comments on the Electric Grid Integration Technical Workshops Summaries: Federal Register Notice Volume 78, No. 35 - Feb. 21, 2013 Notice is hereby given that two documents are publicly available and the Department of Energy is requesting public comments. The documents are the Electricity Distribution System Workshop Discussion Summary and the Electricity Transmission System Workshop Discussion Summary. Written comments are to be received no later than March 25, 2013. For details on how to submit comments, please view the Federal Register Notice, below. Request for Comments on the Electric Grid Integration Technical Workshops

138

Request for Comments on the Electric Grid Integration Technical Workshops  

Broader source: Energy.gov (indexed) [DOE]

for Comments on the Electric Grid Integration Technical for Comments on the Electric Grid Integration Technical Workshops Summaries: Federal Register Notice Volume 78, No. 35 - Feb. 21, 2013 Request for Comments on the Electric Grid Integration Technical Workshops Summaries: Federal Register Notice Volume 78, No. 35 - Feb. 21, 2013 Notice is hereby given that two documents are publicly available and the Department of Energy is requesting public comments. The documents are the Electricity Distribution System Workshop Discussion Summary and the Electricity Transmission System Workshop Discussion Summary. Written comments are to be received no later than March 25, 2013. For details on how to submit comments, please view the Federal Register Notice, below. Request for Comments on the Electric Grid Integration Technical Workshops

139

STEPS TO ESTABLISH A REAL-TIME TRANSMISSION MONITORING SYSTEM FOR TRANSMISSION OWNERS AND OPERATORS WITHIN THE  

Broader source: Energy.gov (indexed) [DOE]

STEPS TO ESTABLISH A REAL-TIME TRANSMISSION MONITORING STEPS TO ESTABLISH A REAL-TIME TRANSMISSION MONITORING SYSTEM FOR TRANSMISSION OWNERS AND OPERATORS WITHIN THE EASTERN AND WESTERN INTERCONNECTIONS A REPORT TO CONGRESS PURSUANT TO SECTION 1839 OF THE ENERGY POLICY ACT OF 2005 Prepared by United States Department of Energy & Federal Energy Regulatory Commission February 3, 2006 Report to Congress Joint Report by the Department of Energy and Federal Energy Regulatory Commission on Steps to Establish a Real-Time Transmission Monitoring System for Transmission Owners and Operators within the Eastern and Western Interconnections February 2006 Executive Summary In August 2003, an electrical outage in one state precipitated a cascading blackout across seven other states and as far north as a province in Canada, leaving more than 50 million

140

Analysis of the ITER LFS Reflectometer Transmission Line System  

SciTech Connect (OSTI)

A critical issue in the design of the ITER Low Field Side (LFS) reflectometer is the transmission line (TL) system. A TL connects each launcher to a diagnostic instrument. Each TL will typically consist of ~42 m of corrugated waveguide and up to 10 miter bends. Important issues for the performance of the TL system are mode conversion and reflections. Minimizing mode conversion and reflections in the waveguide are critical to minimizing standing waves and phase errors in the reflectometer-measured phase. The performance of the corrugated waveguide and miter bends is analyzed and recommendations given.

Hanson, Gregory R [ORNL; Wilgen, John B [ORNL; Bigelow, Tim S [ORNL; Diem, Stephanie J [ORNL; Biewer, Theodore M [ORNL

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

ECEN 720 High-Speed Links Circuits and Systems Lab1 -Transmission Lines  

E-Print Network [OSTI]

1 ECEN 720 High-Speed Links Circuits and Systems Lab1 - Transmission Lines Objective To learn transmission lines and time-domain refectometer (TDR). Introduction Wires are used to transmit clocks and data data communication chip design, the wires are often treated as transmission lines. Proper transmission

Palermo, Sam

142

Number and propagation of line outages in cascading events in electric power transmission systems  

E-Print Network [OSTI]

Number and propagation of line outages in cascading events in electric power transmission systems of transmission lines. We estimate from observed utility data how transmission line outages propagate, and obtain of transmission lines. The multiple mechanisms involved these cascading outages are many and varied, and the power

Dobson, Ian

143

Transmission of the size of units of quantities and verification conditions as applied to measurement systems  

Science Journals Connector (OSTI)

The meaning of transmission of the size of units of quantities and verification conditions applied to measurement systems is considered.

A. A. Danilov

2007-05-01T23:59:59.000Z

144

Summary Report of the INL-JISEA Workshop on Nuclear Hybrud Energy Systems  

SciTech Connect (OSTI)

Hybrid energy systems utilize two or more energy resources as inputs to two or more physically coupled subsystems to produce one or more energy commodities as outputs. Nuclear hybrid energy systems can be used to provide load-following electrical power to match diurnal to seasonal-scale changes in power demand or to compensate for the variability of renewable wind or solar generation. To maintain economical, full rate operation of the nuclear reactor, its thermal energy available when power demand is low could be diverted into making synthetic vehicle fuels of various types. The Institute for Nuclear Energy Science and Technology (INEST) and the Joint Institute for Strategic Energy Analysis (JISEA) co-sponsored an international workshop to identify research topics important in advancing the potential use of hybrid systems with a specific focus on nuclear-renewable hybrid systems. The workshop included presentations ranging from energy challenges and research and development (R&D) directions being pursued by nations to multiple options for hybrid systems. Those options include one that is being commercialized to other opportunities and analysis results quantifying them. The workshop also involved two breakout sessions - one focused on thermal energy management issues especially at unit-operation scale and the second focused on system operations issues including system controls, regulatory issues, technical and economic analysis, and market challenges. A discussion involving the full group focused on more general issues such as societal involvement and participation. Key criteria for selecting hybrid energy system projects and metrics for comparing them were also identified by the full group. The workshop's findings are being used initially by INEST to define topics for a research preproposal solicitation.

Mark Antkowiak; Richard Boardman; Shannon Bragg-Sitton; Robert Cherry; Mark Ruth

2012-07-01T23:59:59.000Z

145

DOE Grid Tech Team Issues Request for Public Comments on Workshop Summaries  

Broader source: Energy.gov (indexed) [DOE]

Grid Tech Team Issues Request for Public Comments on Workshop Grid Tech Team Issues Request for Public Comments on Workshop Summaries DOE Grid Tech Team Issues Request for Public Comments on Workshop Summaries February 21, 2013 - 2:35pm Addthis DOE's Grid Tech Team issued a notice of availability and request for comments on the Electrical Grid Integration Technical Workshop summaries. Public comments on summaries from the distribution system and transmission system workshops will be accepted until March 25, 2013. The complete Federal Register Notice, including details on how to submit comments, is available for download. Addthis Related Articles DOE Convenes Multi-stakeholder Process to Address Privacy for Data Enabled by Smart Grid Technologies Extension of Comment Period on the Draft Integrated, Interagency Pre-Application (IIP) Process for Electric Transmission Projects Requiring

146

Summary Report of the INL-JISEA Workshop on Nuclear Hybrid Energy Systems  

SciTech Connect (OSTI)

The Institute for Nuclear Energy Science and Technology (INEST) and the Joint Institute for Strategic Energy Analysis (JISEA) co-sponsored an international workshop to identify research topics important in advancing the potential use of hybrid systems with a specific focus on nuclear-renewable hybrid systems. The workshop included presentations ranging from energy challenges and research and development directions being pursued by nations to multiple options for hybrid systems. Those options include one that is being commercialized to other opportunities and analysis results quantifying them. The workshop also involved two breakout sessions--one focused on thermal energy management issues especially at unit-operation scale and the second focused on system operations issues including system controls, regulatory issues, technical and economic analysis, and market challenges. A discussion involving the full group focused on more general issues such as societal involvement and participation. Key criteria for selecting hybrid energy system projects and metrics for comparing them were also identified by the full group.

Antkowiak, M.; Ruth, M.; Boardman, R.; Bragg-Sitton, S.; Cherry, R.; Shunn, L.

2012-07-01T23:59:59.000Z

147

US Recovery Act Smart Grid Projects - Electric Transmission Systems | Open  

Open Energy Info (EERE)

American_Transmission_Company_LLC_II_Smart_Grid_Project\" American_Transmission_Company_LLC_II_Smart_Grid_Project\" title=\"American Transmission Company LLC II Smart Grid Project\">American Transmission Company LLC II Smart Grid Project","title":"American Transmission Company LLC II Smart Grid Project","link":null,"lat":43.0116784,"lon":-88.2314813,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""},{"text":"Transmission_Company_LLC_Smart_Grid_Project\" title=\"American Transmission Company LLC Smart Grid Project\">American

148

Roadmap to Secure Control Systems in the Energy Sector 2006- Presentation to the 2008 ieRoadmap Workshop  

Broader source: Energy.gov [DOE]

Presentation by Hank Kenchington on the 2006 roadmap to secure control systems in the energy sector at the ieRoadmap Workshop in Chicago, May 28-29, 2008.

149

Proceedings of the Technology Roadmap Workshop on Communication and Control Systems for Distributed Energy Implementation and Testing, May 2002  

Broader source: Energy.gov [DOE]

This report presents the proceedings of a technical workshop on communication and control systems for the implementation and testing of distributed energy devises such as microturbines, fuel cells, and photovoltaic arrays.

150

Steps to Establish a Real-Time Transmission Monitoring System for  

Broader source: Energy.gov (indexed) [DOE]

Steps to Establish a Real-Time Transmission Monitoring System for Steps to Establish a Real-Time Transmission Monitoring System for Transmission Owners and Operators within the Eastern and Western Interconnections Steps to Establish a Real-Time Transmission Monitoring System for Transmission Owners and Operators within the Eastern and Western Interconnections Steps to establish a real-time transmission monitoring system for transmission owners and operators within the Eastern and Western interconnections: a report to congress pursuant to section 1839 of the Energy Policy Act of 2005. Section 1839 of the Energy Policy Act of 2005 (EPAct 2005) directs the Secretary of Energy (DOE) and the Federal Energy Regulatory Commission (Commission) to study and report to Congress on the steps that must be taken to establish a system to make available to all transmission owners

151

AN INFINITE DIMENSIONAL DESCRIPTOR SYSTEM MODEL FOR ELECTRICAL CIRCUITS WITH TRANSMISSION LINES  

E-Print Network [OSTI]

AN INFINITE DIMENSIONAL DESCRIPTOR SYSTEM MODEL FOR ELECTRICAL CIRCUITS WITH TRANSMISSION LINES TIMO REIS Abstract. In this paper a model of linear electrical circuits with transmission lines is de-coupled with the telegraph equations who describe the behavior of the transmission lines. The resulting system of equations

Reis, Timo

152

Hydrogen Storage Materials Workshop Proceedings Workshop, October...  

Broader source: Energy.gov (indexed) [DOE]

Materials Workshop Proceedings Workshop, October 16th, 2002 Hydrogen Storage Materials Workshop Proceedings Workshop, October 16th, 2002 A workshop on compressed and liquefied...

153

Experimental Breeder Reactor-II Primary Tank System Wash Water Workshop  

Broader source: Energy.gov (indexed) [DOE]

Pre-Developmental Pre-Developmental INL EBR-II Wash Water Treatment Technologies (PBS # ADSHQTD0100 (0003199)) EBR-II Wash Water Workshop - The majority of the sodium has been removed, remaining material is mostly passivated. Similar closure projects have been successfully completed. Engineering needs to be developed to apply the OBA path. Page 1 of 2 Idaho National Laboratory Idaho Experimental Breeder Reactor-II Primary Tank System Wash Water Workshop Challenge In 1994 Congress ordered the shutdown of the Experimental Breeder Reactor-II (EBR-II) and a closure project was initiated. The facility was placed in cold shutdown, engineering began on sodium removal, the sodium was drained in 2001 and the residual sodium chemically passivated to render it less reactive in 2005. Since that time, approximately 700 kg of metallic sodium and 3500 kg of sodium bicarbonate remain in the facility. The

154

ECEN 720 High-Speed Links: Circuits and Systems Lab1 -Transmission Lines  

E-Print Network [OSTI]

1 ECEN 720 High-Speed Links: Circuits and Systems Lab1 - Transmission Lines Objective To learn about transmission lines and time-domain reflectometer (TDR). Introduction Wires are used to transmit. In high speed data communication chip design, the wires are often treated as transmission lines. Proper

Palermo, Sam

155

Rock Mechanics and Enhanced Geothermal Systems: A DOE-sponsored Workshop to Explore Research Needs  

SciTech Connect (OSTI)

This workshop on rock mechanics and enhanced geothermal systems (EGS) was held in Cambridge, Mass., on June 20-21 2003, before the Soil and Rock America 2003 International Conference at MIT. Its purpose was to bring together experts in the field of rock mechanics and geothermal systems to encourage innovative thinking, explore new ideas, and identify research needs in the areas of rock mechanics and rock engineering applied to enhanced geothermal systems. The agenda is shown in Appendix A. The workshop included experts in the fields of rock mechanics and engineering, geological engineering, geophysics, drilling, the geothermal energy production from industry, universities and government agencies, and laboratories. The list of participants is shown is Appendix B. The first day consisted of formal presentations. These are summarized in Chapter 1 of the report. By the end of the first day, two broad topic areas were defined: reservoir characterization and reservoir performance. Working groups were formed for each topic. They met and reported in plenary on the second day. The working group summaries are described in Chapter 2. The final session of the workshop was devoted to reaching consensus recommendations. These recommendations are given in Chapter 3. That objective was achieved. All the working group recommendations were considered and, in order to arrive at a practical research agenda usable by the workshop sponsors, workshop recommendations were reduced to a total of seven topics. These topics were divided in three priority groups, as follows. First-priority research topics (2): {sm_bullet} Define the pre-existing and time-dependent geometry and physical characteristics of the reservoir and its fracture network. That includes the identification of hydraulically controlling fractures. {sm_bullet} Characterize the physical and chemical processes affecting the reservoir geophysical parameters and influencing the transport properties of fractures. Incorporate those processes in reservoir simulators. Second-priority research topics (4): {sm_bullet} Implement and proof-test enhanced fracture detection geophysical methods, such as 3-D surface seismics, borehole seismics, and imaging using earthquake data. {sm_bullet} Implement and proof-test enhanced stress measurement techniques, such as borehole breakout analysis, tilt-meters, and earthquake focal mechanism analysis. {sm_bullet} Implement and proof-test high-temperature down-hole tools for short-term and long-term diagnostics, such as borehole imaging, geophone arrays, packers, and electrical tools.

Francois Heuze; Peter Smeallie; Derek Elsworth; Joel L. Renner

2003-10-01T23:59:59.000Z

156

Transmission and Grid Integration: Electricity, Resources, & Building Systems Integration (Fact Sheet)  

SciTech Connect (OSTI)

Factsheet developed to describe the activites of the Transmission and Grid Integration Group within NREL's Electricity, Resources, and Buildings Systems Integration center.

Not Available

2009-09-01T23:59:59.000Z

157

HIGH-POWER MILLIMETREWAVE TRANSMISSION SYSTEMS AND COMPONENTS FOR ELECTRON CYCLOTRON HEATING OF FUSION PLASMAS  

Science Journals Connector (OSTI)

At the Institute for Plasma Research at the University of Stuttgart, high-power millimetre wave transmission systems for electron cyclotron heating (ECRH) and current drive (ECCD)...

W. Kasparek; G. Dammertz; V. Erckmann

2005-01-01T23:59:59.000Z

158

Enhanced Geothermal Systems (EGS) with CO2as Heat Transmission Fluid  

Broader source: Energy.gov [DOE]

The overall objective of the research is to explore the feasibility of operating enhanced geothermal systems (EGS) with CO2as heat transmission fluid.

159

Control system and method for a power delivery system having a continuously variable ratio transmission  

DOE Patents [OSTI]

A control system and method for a power delivery system, such as in an automotive vehicle, having an engine coupled to a continuously variable ratio transmission (CVT). Totally independent control of engine and transmission enable the engine to precisely follow a desired operating characteristic, such as the ideal operating line for minimum fuel consumption. CVT ratio is controlled as a function of commanded power or torque and measured load, while engine fuel requirements (e.g., throttle position) are strictly a function of measured engine speed. Fuel requirements are therefore precisely adjusted in accordance with the ideal characteristic for any load placed on the engine.

Frank, Andrew A. (1034 Hillside Ave., Madison, WI 53705)

1984-01-01T23:59:59.000Z

160

Abstract--Three known use-based allocation methods for payments of electricity transmission systems are compared.  

E-Print Network [OSTI]

, transmission pricing, transmission use, wheeling allocation, distribution factors. I. INTRODUCTION he worldwide to relate transmission pricing to use of system factors was made by Hugh Rudnick, Rodrigo Palma and Enrique

Catholic University of Chile (Universidad Católica de Chile)

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

HVDC Workshop - April 22, 2013 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

HVDC Workshop - April 22, 2013 HVDC Workshop - April 22, 2013 HVDC Workshop - April 22, 2013 On April 22, 2013, the GTT hosted a workshop to discuss high-voltage direct current (HVDC) transmission technologies and their application in the North American electric grid. Through a series of presentations and group discussions, the workshop also considered technical and institutional challenges to greater deployment. The workshop materials are available below. Return to GTT Activities Workshop Agenda Presentation - Overview - Anjan Bose, DOE Presentation - Keynote - Nari Hingorani Presentation - State of HVDC: Siemens - Peter Kohnstam Presentation - State of HVDC: Alstom - Neil Kirby Presentation - State of HVDC: ABB - Le Tang Presentation - US Case Studies: Anbaric Northeast Transmission Development

162

EA-1982: Parker-Davis Transmission System Programmatic Operations and Maintenance Project; Arizona, California, and Nevada  

Broader source: Energy.gov [DOE]

Western Area Power Administration (Western) is preparing an EA to assess potential environmental impacts of the proposed continuation of operations and maintenance activities and implementation of a vegetation management program on Westerns Parker-Davis Transmission System. These actions would occur on existing transmission line and access road rights-of-way, and at substations and maintenance facilities associated with the transmission system.

163

Installation of PV systems in GreeceReliability improvement in the transmission and distribution system  

Science Journals Connector (OSTI)

Photovoltaic (PV) power systems are becoming one of the most developing investment areas in the field of Renewable Energy Sources (RES). A statement of the status quo of PV power systems in Greece, and their contribution towards the improvement of power system reliability, is the scope of the present paper. Siting and installation of PV power systems is performed according to a recent Greek law, along with environmental and geographical constraints. Meteorological data are computed, formulated and imported to appropriate software in order to simulate the PV units and generate their power output. Data for unserved loads, resulting from load shedding during peak hours, are compared to the above estimated power production. Assuming that a proportion of the eventually unsupplied power could be provided by the accessed power generation of the PV units, the reliability of both transmission and distribution system is improved. The impact on the transmission system is shown by an improvement of LOLP and LOEP indices, whereas peak shaving for the Interconnected Greek Transmission System (IGTS) is also illustrated. For the distribution system the impact is quantified using the distribution system reliability indices SAIDI, SAIFI, and CAIDI. Finally, the resulting improvement is also expressed in financial terms.

Aggelos S. Bouhouras; Antonios G. Marinopoulos; Dimitris P. Labridis; Petros S. Dokopoulos

2010-01-01T23:59:59.000Z

164

EIS-0484: Montana-to-Washington Transmission System Upgrade Project in  

Broader source: Energy.gov (indexed) [DOE]

4: Montana-to-Washington Transmission System Upgrade Project 4: Montana-to-Washington Transmission System Upgrade Project in Washington, Idaho, and Montana EIS-0484: Montana-to-Washington Transmission System Upgrade Project in Washington, Idaho, and Montana SUMMARY This EIS will evaluate the environmental impacts of a proposal to replace roughly 12 miles of transmission line on the Taft-Dworshak 500-kV transmission line, install new series capacitors on the Garrison-Taft 500-kV transmission line, and perform various upgrades to Bell, Hatwai, Dworshak, Garrison, and Hot Springs substations. The project website is http://efw.bpa.gov/environmental_services/Document_Library/M2W/. PUBLIC COMMENT OPPORTUNITIES None available at this time. DOCUMENTS AVALABLE FOR DOWNLOAD May 3, 2012 EIS-0484: Notice of Intent to Prepare an Environmental Impact Statement

165

NIF Workshops  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

NIF Workshops Laser Safety Laser Safety Officer Workshop 2014 For individuals with laser safety responsibility and interest in a research, industrial or academic setting who want...

166

Testing of the Data Transmission System Monika Grothe, Ariane Frey, Massimiliano Turri, Max Wilder  

E-Print Network [OSTI]

Testing of the Data Transmission System Components Monika Grothe, Ariane Frey, Massimiliano Turri August 1999 Abstract This note provides a description of the set­up for testing the data transmission system electronics for the BaBar Silicon Vertex Tracker. #12; Contents 1 List of tested Components 3 2

California at Santa Cruz, University of

167

Procceedings IFIP IEEE International Workshop on Distributed Systems: Operations and Management, October 15-16 1991, Santa Barbara, CA  

E-Print Network [OSTI]

Procceedings IFIP IEEE International Workshop on Distributed Systems: Operations and Management that the security o cer of each component system has discretion regarding the trust invested in other component points of security control. #12;2 THE SCHEMATIC PROTECTION MODEL GMU researchers have been active

Sandhu, Ravi

168

EMTP modeling of CIGRE benchmark based HVDC transmission system operating with weak AC systems  

SciTech Connect (OSTI)

An EMTP based study of a CIGRE benchmark based HVDC system operating with weak ac systems is carried out. The modeled system provides a starting point for (a) educators teaching HVDC transmission courses and (b) for utility planners to develop their own low-cost dedicated digital simulators for training purposes. In this paper, modeling details of the ac-dc system, dc converters and control are presented. To validate the control schemes presented, the HVDC system is tested under ac-dc fault conditions. Results obtained from an EMTP-based study under these fault conditions are also presented in this paper.

Sood, V.K. [Hydro-Quebec, Varennes, Quebec (Canada); Khatri, V.; Jin, H. [Concordia Univ., Montreal, Quebec (Canada). Dept. of Electrical and Computer Engineering

1995-12-31T23:59:59.000Z

169

Department of Energy`s Wire Development Workshop - Superconductivity program for electric systems  

SciTech Connect (OSTI)

The 1996 High-Temperature Superconducting Wire Development Workshop was held on January 31--February 1 at the Crown Plaza Tampa Westshore in Tampa, Florida. The meeting was hosted by Tampa Electric Company and sponsored by the Department of Energy`s Superconductivity Program for Electric Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. Tampa Electric`s Greg Ramon began the meeting by giving a perspective on the changes now occurring in the utility sector. Major program wire development accomplishments during the past year were then highlighted, particularly the world record achievements at Los Alamos and Oak Ridge National Laboratories. The meeting then focussed on three priority technical issues: thallium conductors; AC losses in HTS conductors; and coated conductors on textured substrates. Following in-depth presentations, working groups were formed in each technology area to discuss and critique the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

NONE

1996-06-01T23:59:59.000Z

170

Sensor Technologies for a Smart Transmission System An EPRI White Paper  

Broader source: Energy.gov (indexed) [DOE]

Sensor Technologies for a Smart Transmission System Sensor Technologies for a Smart Transmission System An EPRI White Paper December 2009 December 2009 Page 2 An EPRI White Paper Sensor Technologies for a Smart Transmission System Aging equipment and tight O&M budgets are putting the squeeze on transmission line and substation managers. A new gen- eration of low-cost sensors can help diag- nose equipment health to optimize mainte- nance and prevent catastrophic failures. Power delivery systems are among the largest and most diverse, remotely located investments. There are a num- ber of challenges that utilities face with their transmis- sion line and substation assets: * Existing transmission lines and substations are aging while the required reliability is increasing and the availability of clearance to perform maintenance is

171

Virtual Pipeline System Testbed to Optimize the U.S. Natural Gas Transmission Pipeline System  

SciTech Connect (OSTI)

The goal of this project is to develop a Virtual Pipeline System Testbed (VPST) for natural gas transmission. This study uses a fully implicit finite difference method to analyze transient, nonisothermal compressible gas flow through a gas pipeline system. The inertia term of the momentum equation is included in the analysis. The testbed simulate compressor stations, the pipe that connects these compressor stations, the supply sources, and the end-user demand markets. The compressor station is described by identifying the make, model, and number of engines, gas turbines, and compressors. System operators and engineers can analyze the impact of system changes on the dynamic deliverability of gas and on the environment.

Kirby S. Chapman; Prakash Krishniswami; Virg Wallentine; Mohammed Abbaspour; Revathi Ranganathan; Ravi Addanki; Jeet Sengupta; Liubo Chen

2005-06-01T23:59:59.000Z

172

SAXS Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

pople_title.jpg (17023 bytes) pople_title.jpg (17023 bytes) A workshop to be held at the Stanford Synchrotron Radiation Laboratory In conjunction with the 26th Annual Users' Conference Date: Tuesday October 12, 1999 Time: 1:30 - 5:00PM This workshop is designed as a series of relatively informal lectures in which users in the small-angle X-ray scattering (SAXS) community will share their experience in their particular application of SAXS techniques. Fields which will be reviewed include materials science applications: where selective doping produces novel rheological characteristics within elastomeric polypropylene; materials synthesis: where living polymerization techniques permit construction of dendrimer structures for drug delivery systems; and biological applications: in the determination of

173

Frequency selection of an inductive contactless power transmission system for ocean observing  

Science Journals Connector (OSTI)

Inductive Contactless Power Transmission (ICPT) may suffer considerable power loss due to eddy currents in seawater when applied undersea rather than on land. The loss of power, which is harmful to transmission efficiency, is closely related to the transmission frequency. However, the relationship between the transmission frequency and the efficiency has rarely been studied. In this paper, we analytically deduce the power transmission efficiency in air and the power loss of ICPT in seawater. Based on the theoretical calculation and analysis, guidelines are provided to select the optimum frequency to maximise the efficiency. A case study is then performed to numerically determine the optimum frequency for an undersea ICPT system. Laboratory experiments are conducted to confirm the theoretical results. A prototype ICPT system power is designed and built. A lake trial demonstrates that the designed system is able to transmit power contactless to actual undersea observation network equipment underwater with an efficiency of approximately 85% and a 5mm gap distance.

Jie Zhou; De-jun Li; Ying Chen

2013-01-01T23:59:59.000Z

174

Webinar: Understanding the Interconnection and Transmission Service...  

Broader source: Energy.gov (indexed) [DOE]

Tribal Energy Sufficiency and Economic Development U.S. Department of Energy Schedules Regional Workshops to Provide Expert Input on 2009 Transmission Congestion Study U.S....

175

Transmission | Open Energy Information  

Open Energy Info (EERE)

Transmission Lattice.jpg High-voltage transmission lines form the backbone of electricity systems. Transmission lines are designed to carry large amounts of electricity at...

176

Proceedings of the Department of Energy advanced gas turbine central power systems workshop  

SciTech Connect (OSTI)

The basic objective of the DOE Central Power Systems group is the development of technology for increasing the use of coal in central station electric power generation in an economical and environmentally acceptable manner. The two major research and development areas of this program are the Open Cycle Gas Turbine System and the Closed Cycle Gas Turbine System. Recognizing that the ultimate success of the DOE program is measured by end-user acceptance of the technology developed, the workshop was held to obtain utility industry comments and suggestions on the development of these systems and their potential use by electric power utilities. Representatives of equipment manufacturers, architect and engineering firms, and universities were also invited as participants to provide a comprehensive review of the technology development and implementation process. The 65 participants and observers examined the following topics: technical considerations of the Open Cycle and of the Closed Cycle Gas Turbine program; commercialization of both systems; and regulatory impacts on the development of both systems. Each group evaluated the existing program, indicating R and D objectives that they supported and cited recommendations for modifications and expansion of future R and D work.

D'Angelo, S. (ed.)

1980-04-01T23:59:59.000Z

177

Adaptive neurofuzzy inference system-based pollution severity prediction of polymeric insulators in power transmission lines  

Science Journals Connector (OSTI)

This paper presents the prediction of pollution severity of the polymeric insulators used in power transmission lines using adaptive neurofuzzy inference system (ANFIS) model. In this work, laboratory-based pollution performance tests were carried out ...

C. Muniraj; S. Chandraseka

2011-01-01T23:59:59.000Z

178

On the Efficiency of the New York Independent System Operator Market for Transmission  

E-Print Network [OSTI]

-8061, USA, Chris Marnay, Staff Scientist, Electricity Market Studies, Environmental Energy Technologies 947208061, USA.; Emily S. Bartholomew, Senior Research Associate, Electricity Market Studies, EnvironmentalOn the Efficiency of the New York Independent System Operator Market for Transmission Congestion

179

Security analysis of the interaction between the UK gas and electricity transmission systems  

E-Print Network [OSTI]

Natural gas has become the UKs foremost primary energy source, providing some 39% of our energy needs. The National Transmission System (NTS) has developed from its humble beginnings when natural gas was first discovered ...

Whiteford, James Raymond George

2012-06-25T23:59:59.000Z

180

On adaptive transmission, signal detection and channel estimation for multiple antenna systems  

E-Print Network [OSTI]

This research concerns analysis of system capacity, development of adaptive transmission schemes with known channel state information at the transmitter (CSIT) and design of new signal detection and channel estimation schemes with low complexity...

Xie, Yongzhe

2004-11-15T23:59:59.000Z

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

100 Meter Time of Flight System for Transmission Experiments Michael Rapp, Yaron Danon, Robert Block  

E-Print Network [OSTI]

100 Meter Time of Flight System for Transmission Experiments Michael Rapp, Yaron Danon, Robert of the detectors was chosen to take advantage of the neutron beam geometry at the detector location, 100 meters

Danon, Yaron

182

Reliability analysis of urban gas transmission and distribution system based on FMEA and correlation operator  

Science Journals Connector (OSTI)

In order to improve the safety management of urban gas transmission and distribution system, failure mode and effects analysis (FMEA) was used to construct the reliability analysis ... the risk priority number (R...

Su Li; Weiguo Zhou

2014-12-01T23:59:59.000Z

183

Low pressure electrospray ionization system and process for effective transmission of ions  

DOE Patents [OSTI]

A system and method are disclosed that provide up to complete transmission of ions between coupled stages with low effective ion losses. A novel "interfaceless" electrospray ionization system is further described that operates the electrospray at a reduced pressure such that standard electrospray sample solutions can be directly sprayed into an electrodynamic ion funnel which provides ion focusing and transmission of ions into a mass analyzer.

Tang, Keqi (Richland, WA); Page, Jason S. (Kennewick, WA); Kelly, Ryan T. (Wet Richland, WA); Smith, Richard D. (Richland, WA)

2010-03-02T23:59:59.000Z

184

Low pressure electrospray ionization system and process for effective transmission of ions  

DOE Patents [OSTI]

Systems and methods that provide up to complete transmission of ions between coupled stages with low effective ion losses. An "interfaceless" electrospray ionization system is further described that operates an electrospray at a reduced pressure such that standard electrospray sample solutions can be directly sprayed into an electrodynamic ion funnel which provides ion focusing and transmission of ions into a mass analyzer. Furthermore, chambers maintained at different pressures can allow for more optimal operating conditions for an electrospray emitter and an ion guide.

Tang, Keqi (Richland, WA); Page, Jason S (Kennewick, WA); Kelly, Ryan T (West Richland, WA); Smith, Richard D (Richland, WA)

2012-05-08T23:59:59.000Z

185

July 31 Webinar to Provide Guidance on Transmission Feasibility and System  

Broader source: Energy.gov (indexed) [DOE]

July 31 Webinar to Provide Guidance on Transmission Feasibility and July 31 Webinar to Provide Guidance on Transmission Feasibility and System Impact Studies July 31 Webinar to Provide Guidance on Transmission Feasibility and System Impact Studies July 24, 2013 - 10:32am Addthis The U.S. Department of Energy (DOE) Office of Indian Energy, the DOE Office of Energy Efficiency and Renewable Energy's Tribal Energy Program, and the Western Area Power Administration (WAPA) will present the next Tribal Renewable Energy Series webinar, "Conducting Transmission Feasibility and System Impact Studies," on Wednesday, July 31, 2013, from 1:00 p.m. to 2:30 p.m. Eastern Time. The development of more renewable energy resources raises challenges and opportunities for the electric grid relating to upgrades and potential new construction. Likewise, commercial-scale renewable energy development

186

Enhanced Geothermal Systems (EGS) with CO2as Heat Transmission...  

Broader source: Energy.gov (indexed) [DOE]

precipitation with spatial and temporal flow variations in CO2brinerock systems Tracer Methods for Characterizing Fracture Stimulation in Engineered Geothermal Systems (EGS)...

187

Electrical Collection and Transmission Systems for Offshore Wind Power: Preprint  

SciTech Connect (OSTI)

The electrical systems needed for offshore wind farms to collect power from wind turbines--and transmit it to shore--will be a significant cost element of these systems. This paper describes the development of a simplified model of the cost and performance of such systems.

Green, J.; Bowen, A.; Fingersh, L.J.; Wan, Y.

2007-03-01T23:59:59.000Z

188

Spring 2009 Technical Workshop  

Broader source: Energy.gov (indexed) [DOE]

Spring 2009 Technical Workshop Spring 2009 Technical Workshop in Support of U.S. Department of Energy 2009 Congestion Study Webcast, transcript, and presentations available at: http://www.congestion09.anl.gov/ Crowne Plaza Chicago O'Hare Hotel & Conference Center March 25-26, 2009 Agenda Day 1 - Wednesday, March 25, 2009 9:00 a.m. Registration Check-In & Continental Breakfast 10:00 a.m. DOE Welcome/Purpose of Workshop David Meyer, Senior Policy Advisor, Office of Electricity Delivery and Energy Reliability, U.S. Department of Energy (DOE-OE) 10:15 a.m. Session 1 - Historic Congestion in the Western Interconnection The Western Electric Coordinating Council Transmission Expansion Planning and Policy Committee has conducted an analysis of historic congestion in the Western

189

Application of multi-variable control for automatic frequency controller of HVDC transmission system  

SciTech Connect (OSTI)

In an HVDC transmission system that links two ac power systems, the automatic frequency controller (AFC) calculates power to be interchanged between the two ac systems according to their frequencies thereby improving the frequency characteristics of the two power systems. This paper introduces a newly developed dc AFC system, which applies a multi-variable control to the dc system-based frequency control. It is capable of controlling the frequencies of the two ac systems optimally while maintaining their stability. This system was developed for one of Japan's HVDC transmission facilities and produced good results in a combined test using a power system simulator. The field installation will be completed in March 1993, when the AFC system will enter service.

Sanpei, Masatoshi (Electric Power Development Co., Tokyo (Japan)); Kakehi, Atsuyuki; Takeda, Hideo (Toshiba Corp., Tokyo (Japan))

1994-04-01T23:59:59.000Z

190

Workshop on environmental assessment. [Regulation of applications of nuclear energy and related ancillary systems  

SciTech Connect (OSTI)

Objectives of the workshop were: to review and evaluate the state-of-the-art of environmental impact assessments as applied to the regulation of applications of nuclear energy and related ancillary systems; to identify areas where existing technology allows establishing acceptable methods or standard practices that will meet the requirements of the NRC regulations, standards and guides for both normal operations and off-standard conditions including accident considerations; to illuminate topics where existing models or analytical methods are deficient because of unverified assumptions, a paucity of empirical data, conflicting results reported in the literature or a need for observation of operation systems; to compile, analyze and synthesize a prioritized set of research needs to advance the state-of-the-art to the level which will meet all of the requirements of the Commission's regulations, standards and guides; and to develop bases for maintaining the core of regulatory guidance at the optimum level balancing technical capabilities with practical considerations of cost and value to the regulatory process. The discussion held in small group sessions on aquatic, atmospheric, and terrestrial pathways are presented. The following research needs were identified as common to all three groups: validation of models; characterization of source terms; development of screening techniques; basis for de minimis levels of contamination; and updating of objectives for environmental monitoring programs.

Watson, E.C. (comp.)

1982-07-01T23:59:59.000Z

191

Impact of Utility-Scale Distributed Wind on Transmission-Level System Operations  

SciTech Connect (OSTI)

This report presents a new renewable integration study that aims to assess the potential for adding distributed wind to the current power system with minimal or no upgrades to the distribution or transmission electricity systems. It investigates the impacts of integrating large amounts of utility-scale distributed wind power on bulk system operations by performing a case study on the power system of the Independent System Operator-New England (ISO-NE).

Brancucci Martinez-Anido, C.; Hodge, B. M.

2014-09-01T23:59:59.000Z

192

Analysis of transmission system faults in the phase domain  

E-Print Network [OSTI]

the zero, positive and negative sequences. d) Calculate the post-fault line current ij 2 2 2 ij j ij z VI ?= (2.15) where ij is the primitive impedance element between nodes i and j. After all these sequence quantities... in Figure 5. The data of this system is listed in Tables 1, 2, and 3. Figure 5. System diagram for the 3-bus system Table 1 Generator data (3 Bus system) Generator impedance(p.u.) # Gen. connection P N Z 1 Y-grounded 0.05j 0.05j 0.15j 2...

Zhu, Jun

2004-11-15T23:59:59.000Z

193

PKI Workshop | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

PKI Workshop PKI Workshop PKI Workshop.pdf More Documents & Publications ICAM Workshop Radio and Spectrum Management Ad Hoc Meetings...

194

The Reliability Investigation on ACSR Splice Connector Systems Used in Overhead Power transmission Lines  

SciTech Connect (OSTI)

Due to material discontinuity and inherited forming mechanism from a crimped-type splice connector, the associated conductor-connector system is highly sensitive to system components aging, especially during high-temperature operations. Furthermore, due to the increase in power demand and limited investment in new infrastructure, existing overhead power transmission lines often need to operate at temperatures higher than the original designed values. This has led to the accelerated aging and degradation of conductor-connector systems. The implications of connector aging are two-fold: (1) significant increase in resistivity of the splice connector and (2) significant reduction in the connector clamping strength. Therefore, splice connectors are one of the weakest links in the electric power transmission infrastructure. In this paper we will discuss the reliability of splice connector systems, including both single stage and two stage splice connectors, used in ACSR conductor of transmission lines under high temperature operations.

Wang, Jy-An John [ORNL] [ORNL; Jiang, Hao [ORNL] [ORNL; Ren, Fei [ORNL] [ORNL

2012-01-01T23:59:59.000Z

195

Summary of the Geographic Information System workshop, held in Chicago, Illinois, May 29--30, 1991. Final report, December 1989--December 1991  

SciTech Connect (OSTI)

The Gas Research Institute, in conjunction with Argonne National Laboratory, sponsored a workshop on May 29--30, 1991, in Chicago, Illinois, to give gas utilities the opportunity to learn about the availability, applications, and benefits of Geographic Information Systems (GISs). This report is a synopsis of that workshop and contains brief discussions, followed by copies of the viewgraphs shown at the workshop, for the following GIS topics: (1) introduction to GIS, (2) data development, (3) analytical functions, (4) use for gas pipeline right-of-way applications, and (5)video imaging and simulation.

Thompson, P J; Sullivan, R G; Sundell, R C; Messersmith, J [Argonne National Lab., IL (United States)] [Argonne National Lab., IL (United States)

1991-12-01T23:59:59.000Z

196

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-35)  

Broader source: Energy.gov (indexed) [DOE]

14, 2001 14, 2001 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-35) James Jellison - TFO/Olympia Natural Resource Specialist Proposed Action: Vegetation Management along the Chehalis-Mayfield No. 1 230 kV Transmission Line ROW and the Mossy Rock-Chehalis Transmission Line ROW, between 7/1 to 27/10. The proposed work will be accomplished in the indicated sections of the transmission line corridor with an average corridor width of 162 feet. Location: The ROW is located in Lewis County, WA, being in the Olympia Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-ways

197

Multiannual patterns of influenza A transmission in Chinese live bird market systems  

E-Print Network [OSTI]

Multiannual patterns of influenza A transmission in Chinese live bird market systems Kim M. Pepin and emergence in humans is confounded by insufficient empirical data on the ecology and dynamics of AIV in poultry systems. To address this gap, we quantified incidence patterns for 13 hemagglutinin subtypes

Webb, Colleen

198

Enhanced Geothermal Systems (EGS) with CO2as Heat Transmission...  

Broader source: Energy.gov (indexed) [DOE]

study heat extraction from hot porous systems by injection of cold CO 2 . * Reactive chemistry experiments for CO 2 -brine-rock are being assembled (INL). 6 | US DOE Geothermal...

199

Nonlinear control of a coupled PDE/ODE system modeling a switched power converter with a transmission line  

E-Print Network [OSTI]

with a transmission line Jamal Daafouz, Marius Tucsnak and Julie Valein Avril 2014 Abstract We consider an infinite dimensional system modeling a boost converter connected to a load via a transmission line. The governing.tucsnak@univ-lorraine.fr, julie.valein@univ-lorraine.fr 1 #12;converters connected to transmission lines is a very difficult task

Valein, Julie - Institut de Mathématiques ?lie Cartan, Université Henri Poincaré

200

Sensor, method and system of monitoring transmission lines  

SciTech Connect (OSTI)

An apparatus, method, and system for measuring the magnetic field produced by phase conductors in multi-phase power lines. The magnetic field measurements are used to determine the current load on the conductors. The magnetic fields are sensed by coils placed sufficiently proximate the lines to measure the voltage induced in the coils by the field without touching the lines. The x and y components of the magnetic fields are used to calculate the conductor sag, and then the sag data, along with the field strength data, can be used to calculate the current load on the line and the phase of the current. The sag calculations of this invention are independent of line voltage and line current measurements. The system applies a computerized fitter routine to measured and sampled voltages on the coils to accurately determine the values of parameters associated with the overhead phase conductors.

Syracuse, Steven J.; Clark, Roy; Halverson, Peter G.; Tesche, Frederick M.; Barlow, Charles V.

2012-10-02T23:59:59.000Z

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Reliability modeling of transmission and distribution systems including dependent failures  

E-Print Network [OSTI]

is considered. Therefore, the trans i t ion rate mat r i x of the entire system need not be generated. Th i s method is compared wi th the sequential method for normal and stormy weather condit ions, and is then extended to include m weather conditions... . 9 E . Cut -Set Equations 10 III M A R K O V C U T - S E T M E T H O D 13 A . Basic Approach 13 B . Markov Cut -Set Me thod 13 C . Examp le 18 D . Compar ison wi th the Sequential Me thod 22 E . Cut-Sets w i th m Weather States 24 F . Extens...

Beydoun, Rami Sami

2012-06-07T23:59:59.000Z

202

2012 National Electric Transmission Congestion Study - Philadelphia  

Broader source: Energy.gov (indexed) [DOE]

Philadelphia Philadelphia Workshop 2012 National Electric Transmission Congestion Study - Philadelphia Workshop On December 6, 2011, DOE hosted a regional pre-study workshop in Philadelphia, PA to receive input and suggestions concerning the 2012 National Electric Transmission Congestion Study. The workshop flyer, agenda, presentations, and full transcript are available below. National Electric Transmission Congestion Study 2012 Eastern Workshops.pdf 12-06-11 Congestion Workshop Agenda - Philadelphia (final).pdf Introduction by David Meyer, DOE.pdf Presentation by Edward Finley, NCUC.pdf Presentation by Betty Ann Kane, DC PSC.pdf Presentation by Robert Bradish, American Electric Power.pdf Presentation by John Buechler, NYISO.pdf Presentation by Jim Busbin, Southern Company.pdf

203

2012 Microgrid Workshop Summary Released  

Broader source: Energy.gov [DOE]

The Department of Energy has released the summary report from the July 30-31, 2012 Microgrid Workshop presented by the Office of Electricity Delivery and Energy Reliability at the Illinois Institute of Technology in Chicago. The workshop was held in response to discussions at the preceding DOE Microgrid Workshop, held in August 2011, which called for sharing lessons learned and best practices for system integration from existing projects in the U.S. (including military microgrids) and internationally.

204

An optimally designed stack effluent sampling system with transpiration for active transmission enhancement  

E-Print Network [OSTI]

for which there is no true real-time measurement is particulate mass. A light attenuation system that is based on the opacity of the stack gas is used in an attempt to fill this void. Though this system provides monitoring on a real time basis...AN OPTIMALLY DESIGNED STACK EFFLUENT SAMPLING SYSTEM WITH TRANSPIRATION FOR ACTIVE TRANSMISSION ENHANCEMENT TROY J. SCHROEDER Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements...

Schroeder, Troy J.

1995-01-01T23:59:59.000Z

205

Honda Transmission Technical Center  

High Performance Buildings Database

Russells Point, OH The Honda Transmission Technical Center is located on the Honda of America Manufacturing Plant facility site in Russells Point, Ohio. This facility is used for product engineering and market quality testing and analysis of automatic transmissions. The building contains a large workshop area for ten cars, a future dynamometer, two laboratories, an open office area, three conference rooms, a break room, restrooms, and related support areas.

206

Workshop on data acquisition and trigger system simulations for high energy physics  

SciTech Connect (OSTI)

This report discusses the following topics: DAQSIM: A data acquisition system simulation tool; Front end and DCC Simulations for the SDC Straw Tube System; Simulation of Non-Blocklng Data Acquisition Architectures; Simulation Studies of the SDC Data Collection Chip; Correlation Studies of the Data Collection Circuit & The Design of a Queue for this Circuit; Fast Data Compression & Transmission from a Silicon Strip Wafer; Simulation of SCI Protocols in Modsim; Visual Design with vVHDL; Stochastic Simulation of Asynchronous Buffers; SDC Trigger Simulations; Trigger Rates, DAQ & Online Processing at the SSC; Planned Enhancements to MODSEM II & SIMOBJECT -- an Overview -- R.; DAGAR -- A synthesis system; Proposed Silicon Compiler for Physics Applications; Timed -- LOTOS in a PROLOG Environment: an Algebraic language for Simulation; Modeling and Simulation of an Event Builder for High Energy Physics Data Acquisition Systems; A Verilog Simulation for the CDF DAQ; Simulation to Design with Verilog; The DZero Data Acquisition System: Model and Measurements; DZero Trigger Level 1.5 Modeling; Strategies Optimizing Data Load in the DZero Triggers; Simulation of the DZero Level 2 Data Acquisition System; A Fast Method for Calculating DZero Level 1 Jet Trigger Properties and Physics Input to DAQ Studies.

NONE

1992-12-31T23:59:59.000Z

207

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-09)  

SciTech Connect (OSTI)

BPA proposes to clear unwanted vegetation from the rights of way and access roads for BPA's McNary-Santiam No. 1 Transmission Line, beginning in the summer of 2000 and ending in July, 2001. This Supplemental Analysis finds that: (1) the proposed actions are substantially consistent with the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285) and ROD; and (2) there are no new circumstances or information relevant to environmental concerns and bearing on the proposed actions or their impacts. Therefore, no further NEPA documentation is required.

N /A

2001-05-01T23:59:59.000Z

208

EA-1982: Parker-Davis Transmission System Routine Operation and Maintenance Project and Proposed Integrated Vegetation Management Plan  

Broader source: Energy.gov [DOE]

Western Area Power Administration (Western) is preparing an EA to assess potential environmental impacts of the proposed continuation of operations and maintenance activities and implementation of a vegetation management program on Westerns Parker-Davis Transmission System. These actions would occur on existing transmission line and access road rights-of-way, and at substations and maintenance facilities associated with the transmission system.

209

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-40)  

Broader source: Energy.gov (indexed) [DOE]

9, 2002 9, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-40) William T. Erickson - TFP/Walla Walla Natural Resource Specialist Proposed Action: Vegetation Management along the Allston-Keeler 500 kV Transmission Line ROW exclusive to BLM lands between 8/4 through 27/4. The proposed work will be accomplished in the indicated sections of the transmission line corridor with an average corridor width of 150 feet. Location: The ROW is located in Washington and Columbia County, in the State of Oregon, Olympia Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-ways

210

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-06)  

SciTech Connect (OSTI)

BPA proposes to apply selected herbicides to control annual weeds that are competing with native grasses that were seeded two years ago. Herbicides will also be applied at the base of the existing wooden transmission line poles located in the pasture area. BPA would conduct the vegetation control with the goal of promoting native grass growth and to provide fire protection for the wooden transmission line poles. The pasture area is, for the most part, flat with elevation increasing towards the northwest corner. Slopes are not steep in that area. This project meets the standards and guidelines for the Transmission System Vegetation Management Program Final Environmental Impact Statement (FEIS) and Record of Decision (ROD).

N /A

2001-04-13T23:59:59.000Z

211

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-11)  

SciTech Connect (OSTI)

BPA proposes to clear unwanted vegetation in the rights-of-ways and around tower structures that may impede the operation and maintenance of the subject transmission line. Also, access road clearing will be conducted. All work will be in accordance with the National Electrical Safety Code and BPA standards. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA's overall goal is to have low-growing plant communities along the rights-of-way to control the development of potentially threatening vegetation. This project meets the standards and guidelines for the Transmission System Vegetation Management Program Final Environmental Impact Statement (FEIS) and Record of Decision (ROD).

N /A

2001-05-15T23:59:59.000Z

212

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-12)  

SciTech Connect (OSTI)

BPA proposes to clear unwanted vegetation in the rights-of-ways and around tower structures that may impede the operation and maintenance of the subject transmission line. Also, access road clearing will be conducted. All work will be in accordance with the National Electrical Safety Code and BPA standards. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA's overall goal is to have low-growing plant communities along the rights-of-way to control the development of potentially threatening vegetation. This project meets the standards and guidelines for the Transmission System Vegetation Management Program Final Environmental Impact Statement (FEIS) and Record of Decision (ROD).

N /A

2001-05-15T23:59:59.000Z

213

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-13)  

SciTech Connect (OSTI)

BPA proposes to clear unwanted vegetation in the rights-of-ways and around tower structures that may impede the operation and maintenance of the subject transmission line. Also, access road clearing will be conducted. All work will be in accordance with the National Electrical Safety Code and BPA standards. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA's overall goal is to have low-growing plant communities along the rights-of-way to control the development of potentially threatening vegetation. This project meets the standards and guidelines for the Transmission System Vegetation Management Program Final Environmental Impact Statement (FEIS) and Record of Decision (ROD).

N /A

2001-06-06T23:59:59.000Z

214

2009 National Electric Transmission Congestion Study - San Francisco  

Broader source: Energy.gov (indexed) [DOE]

San San Francisco Workshop 2009 National Electric Transmission Congestion Study - San Francisco Workshop On June 11, 2008, DOE hosted a regional pre-study workshop in San Francisco, CA to receive input and suggestions concerning the 2009 National Electric Transmission Congestion Study. The agenda, full transcript, and documents submitted for consideration for the 2009 study are available below. 6-11-08 Congestion Workshop Agenda - San Francisco, CA.pdf Transcript - 2009 National Electric Transmission Congestion Study San Francisco Workshop.pdf California Initiatives To Be Considered in DOE's 2009 Congestion Study, submitted at 2009 Congestion Study San Francisco workshop.pdf Arizona Renewable Transmission Task Force BTA Response, submitted at 2009 Congestion Study San Francisco workshop.pdf

215

2009 National Electric Transmission Congestion Study - San Francisco  

Broader source: Energy.gov (indexed) [DOE]

San San Francisco Workshop 2009 National Electric Transmission Congestion Study - San Francisco Workshop On June 11, 2008, DOE hosted a regional pre-study workshop in San Francisco, CA to receive input and suggestions concerning the 2009 National Electric Transmission Congestion Study. The agenda, full transcript, and documents submitted for consideration for the 2009 study are available below. 6-11-08 Congestion Workshop Agenda - San Francisco, CA.pdf Transcript - 2009 National Electric Transmission Congestion Study San Francisco Workshop.pdf California Initiatives To Be Considered in DOE's 2009 Congestion Study, submitted at 2009 Congestion Study San Francisco workshop.pdf Arizona Renewable Transmission Task Force BTA Response, submitted at 2009 Congestion Study San Francisco workshop.pdf

216

Vice President, Transmission Marketing & Sales  

Broader source: Energy.gov [DOE]

Within Transmission Services at Bonneville Power Administration (BPA), Transmission Marketing and Sales (TS) provides open access to the Federal Transmission System (FTS) consistent with...

217

Agenda for San Francisco Workshop  

Broader source: Energy.gov (indexed) [DOE]

Transmission Congestion Study Workshop Transmission Congestion Study Workshop Skirvin Hilton Hotel Oklahoma City, Oklahoma June 18, 2008 AGENDA 12:00 - 1:00 pm Registration 1:00 - 1:05 pm Welcome The Honorable Bob Anthony, Commissioner Oklahoma Corporation Commission 1:05 - 1:15 pm DOE Presentation: Plans for the 2009 Congestion Study and Objectives of Workshop 1:15 - 2:30 pm Panel I The Honorable Tom Sloan, Representative, 45 th District, Kansas House of Representatives The Honorable Susan Wefald, President, North Dakota Public Service Commission The Honorable Lauren Azar, Commissioner, Public Service Commission of Wisconsin Sandy Hochstetter, Vice President, Arkansas Electric Cooperative Corporation Mike Proctor, Chief Utility Economist, Missouri Public Service Commission

218

Evaluation of power system security and development of transmission pricing method  

E-Print Network [OSTI]

benefits in transmission services. The proposed method shows the transmission transaction cost of reliability benefits when transmission line capacities are considered. The ratio between allocation by transmission line capacity-use and allocation...

Kim, Hyungchul

2004-11-15T23:59:59.000Z

219

Cost-Effectivenessof PhotovoltaicGenerationIn A Transmission-Constrained Load Area of An InterconnectedSystem  

E-Print Network [OSTI]

stations and then deliver that energy through the interconnected transmission and distribution systems are important factors for electricity enterprises to consider in their planning activities. One new important Abstract: Electric power systems of today are experiencing a difficulty of constrained transmission lines

Gross, George

220

Impact of Distribution-Connected Large-Scale Wind Turbines on Transmission System Stability during Large Disturbances: Preprint  

SciTech Connect (OSTI)

This work examines the dynamic impacts of distributed utility-scale wind power during contingency events on both the distribution system and the transmission system. It is the first step toward investigating high penetrations of distribution-connected wind power's impact on both distribution and transmission stability.

Zhang, Y.; Allen, A.; Hodge, B. M.

2014-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Summary Report on Stakeholder Workshop  

E-Print Network [OSTI]

: Devon Manz Electric Power and Propulsion Systems Lab One Research Circle, Niskayuna, NY, 12309 PhoneSummary Report on Stakeholder Workshop Prepared for U.S. Department of Energy Office of Electricity on Stakeholder Workshop By GE Global Research Niskayuna, New York And University of Hawaii Hawaii Natural Energy

222

The design of high-speed data transmission method for a small nuclear physics DAQ system  

E-Print Network [OSTI]

A large number of data need to be transmitted in high-speed between Field Programmable Gate Array (FPGA) and Advanced RISC Machines 11 micro-controller (ARM11) when we design a small data acquisition (DAQ) system for nuclear experiments. However, it is a complex problem to beat the target. In this paper, we will introduce a method which can realize the high-speed data transmission. By this way, FPGA is designed to acquire massive data from Front-end electronics (FEE) and send it to ARM11, which will transmit the data to other computer through the TCP/IP protocol. This paper mainly introduces the interface design of the high-speed transmission between FPGA and ARM11, the transmission logic of FPGA and the driver program of ARM11. The research shows that the maximal transmission speed between FPGA and ARM11 by this way can reach 50MB/s theoretically, while in nuclear physics experiment, the system can acquire data with the speed of 2.2MB/s.

Zhou, Wenxiong; Nan, Gangyang; Zhang, Jianchuan

2013-01-01T23:59:59.000Z

223

The electric delivery system-a complex network of transmission and distribu  

Broader source: Energy.gov (indexed) [DOE]

electric delivery system-a complex network of transmission and distribu- electric delivery system-a complex network of transmission and distribu- tion lines, substations, and electrical components-is aging. To deliver more electricity and ensure reliability, the grid needs to be modernized. As the grid is being upgraded, it is also being challenged by increased needs to integrate variable renewable energy resources such as solar and wind, the potential growth of electric vehicles and related charging infrastructure, and the potential development of new electricity market designs and operating practices. To help decision makers better understand how these changes and challenges are shaping electricity delivery systems, as well as provide the industry with the tools necessary to cope with the new designs, the Reliability and Markets activ-

224

Electricity Transmission, A Primer | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Transmission, A Primer Electricity Transmission, A Primer This primer on electric transmission is intended to help policymakers understand the physics of the transmission system,...

225

Gas mixing system for imaging of nanomaterials under dynamic environments by environmental transmission electron microscopy  

SciTech Connect (OSTI)

A gas mixing manifold system that is capable of delivering a stable pressure stream of a desired composition of gases into an environmental transmission electron microscope has been developed. The system is designed to provide a stable imaging environment upon changes of either the composition of the gas mixture or upon switching from one gas to another. The design of the system is described and the response of the pressure inside the microscope, the sample temperature, and sample drift in response to flow and composition changes of the system are reported.

Akatay, M. Cem [School of Materials Engineering and Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907 (United States)] [School of Materials Engineering and Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907 (United States); Zvinevich, Yury; Ribeiro, Fabio H., E-mail: fabio@purdue.edu, E-mail: estach@bnl.gov [Forney Hall of Chemical Engineering, Purdue University, West Lafayette, Indiana 47907 (United States); Baumann, Philipp [Computer Sciences, University of Applied Sciences of Northeastern Switzerland, 4132 Muttenz, Switzerland and Department of Physics, Yeshiva University, New York, New York 10016 (United States)] [Computer Sciences, University of Applied Sciences of Northeastern Switzerland, 4132 Muttenz, Switzerland and Department of Physics, Yeshiva University, New York, New York 10016 (United States); Stach, Eric A., E-mail: fabio@purdue.edu, E-mail: estach@bnl.gov [Center for Functional Nanomaterials, Brookhaven National Laboratory, Upton, New York 11973 (United States)

2014-03-15T23:59:59.000Z

226

Impact of Transmission on Resource Adequacy in Systems with Wind and Solar Power: Preprint  

SciTech Connect (OSTI)

Variable generation is on track to become a significant contributor to electric power systems worldwide. Thus, it is important to analyze the effect that renewables will have on the reliability of systems. In this paper we present a new tool being implemented at the National Renewable Energy Laboratory, which allows the inclusion of variable generation in the power system resource adequacy. The tool is used to quantify the potential contribution of transmission to reliability in highly interconnected systems and an example is provided using the Western Interconnection footprint.

Ibanez, E.; Milligan, M.

2012-02-01T23:59:59.000Z

227

Modeling Interregional Transmission Congestion in the NationalEnergy Modeling System  

SciTech Connect (OSTI)

Congestion analysis using National Energy Modeling National Energy Modeling System (NEMS) or NEMS-derivatives, such as LBNL-NEMS, is subject to significant caveats because the generation logic inherent in NEMS limits the extent to which interregional transmission can be utilized and intraregional transmission is not represented at all. The EMM is designed primarily to represent national energy markets therefore regional effects may be simplified in ways that make congestion analysis harder. Two ways in particular come to mind. First, NEMS underutilizes the capability of the traditional electric grid as it builds the dedicated and detached grid. Second, it also undervalues the costs of congestion by allowing more transmission than it should, due to its use of a transportation model rather than a transmission model. In order to evaluate benefits of reduced congestion using LBNL-NEMS, Berkeley Lab identified three possible solutions: (1) implement true simultaneous power flow, (2) always build new plants within EMM regions even to serve remote load, and (3) the dedicated and detached grid should be part of the known grid. Based on these findings, Berkeley Lab recommends the following next steps: (1) Change the build logic that always places new capacity where it is needed and allow the transmission grid to be expanded dynamically. (2) The dedicated and detached grid should be combined with the traditional grid. (3) Remove the bias towards gas fired combine cycle and coal generation, which are the only types of generation currently allowed out of region. (4) A power flow layer should be embedded in LBNL-NEMS to appropriately model and limit transmission.

Gumerman, Etan; Chan, Peter; Lesieutre, Bernard; Marnay, Chris; Wang, Juan

2006-05-25T23:59:59.000Z

228

Proceedings: Commercial Refrigeration Research Workshop  

SciTech Connect (OSTI)

Improving refrigeration systems for commercial use can enhance both utility load factors and supermarket profits. This workshop has pinpointed research needs in commercial refrigeration and systems integration for a supermarket environment.

None

1984-10-01T23:59:59.000Z

229

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-15)  

SciTech Connect (OSTI)

BPA proposes to clear unwanted vegetation in the rights-of-ways and around tower structures that may impede the operation and maintenance of the subject transmission lines. Work also includes clearing of a small (<1/4 mile) section of access road. All work will be in accordance with the National Electrical Safety Code and BPA standards. See Section 1.1 of the attached checklist for detailed information on each section of the referenced transmission lines. BPA will conduct the vegetation control with the goal of removing tall-growing vegetation that is currently or will soon be a hazard to the transmission lines and where possible to promote low-growing plant communities in the right-of-way. This project meets the standards and guidelines for the Transmission System Vegetation Management Program Final Environmental Impact Statement (FEIS) and Record of Decision (ROD). The vegetation needing control is mainly Douglas Fir, Alder, and blackberries as indicated in Section 1.2 of the attached checklist. The work involved in the ROW includes: clearing tall growing vegetation that is currently or will soon pose a hazard to the lines; treating the associated stumps and re-sprouts with herbicide to ensure that the roots are killed preventing new sprouts; and selectively eliminating tall growing vegetation before it reaches a height or density to begin competing with low-growing vegetation. All work will take place in existing rights-of-ways and around transmission structures. All work will be accomplished by selective vegetation control methods to assure that there is little potential harm to non-target vegetation and to low-growing plants. The work will provide system reliability and fire protection. Also, all off right-of-way trees that are potentially unstable and will fall within a minimum distance or into the zone where the conductors swing will be removed. Access roads will be treated using mowing and herbicide applications. The work will provide system reliability. The subject transmission lines range from 115kV to 230kV and are made up of accompanying access roads, steel and wooden transmission line structures and associated switching platforms. The minimum clearance ranges from 21 feet for 115kV lines to 23 feet for 230kV lines. ROW easement widths vary along the length of the project. Vegetation control for this project is designed to provide a 3 year maintenance free interval. In summary, the overall vegetation management scheme will be to selectively remove tall growing vegetation then apply selective herbicide treatment using cut stump applications.

N /A

2001-06-19T23:59:59.000Z

230

Reliability evaluation for large-scale bulk transmission systems: Volume 1, Comparative evaluation, method development, and recommendations: Final report  

SciTech Connect (OSTI)

This volume (1 of 2) contains a comparative evaluation of existing transmission system reliability programs (SYREL, GATOR, RECS) and relevant mathematical methods for transmission reliability analysis. Several new and enhanced methods in the areas of network analysis, contingency selection, remedial action, and reliability index calculation, developed and tested during the project, are described. Recommendations for methods to be used in a production grade transmission reliability assessment program are presented. 69 figs., 41 tabs.

Lam, B.P.; Lawrence, D.J.; Reppen, N.D.; Ringlee, R.J.

1988-01-01T23:59:59.000Z

231

Natural Gas Infrastructure R&D and Methane Emissions Mitigation Workshop  

Broader source: Energy.gov [DOE]

The Advanced Manufacturing Office (AMO) at the U.S. Department of Energy (DOE)s Office of Energy Efficiency and Renewable Energy and the Office of Fossil Energy (FE) hosted a workshop, November 12-13, 2014, in Coraopolis, Pennsylvania, as a follow-up to the Presidents Climate Action Plan and the DOE meeting series on reducing methane emissions from natural gas pipeline systems. The workshop is part of the larger Administration Strategy to Reduce Methane Emissions associated with natural gas transmission and distribution infrastructure.

232

Integrating Renewable Energy into the Transmission and Distribution System of the U.S. Virgin Islands  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Renewable Energy Renewable Energy into the Transmission and Distribution System of the U.S. Virgin Islands Kari Burman, Dan Olis, Vahan Gevorgian, Adam Warren, and Robert Butt National Renewable Energy Laboratory Peter Lilienthal and John Glassmire HOMER Energy LLC Technical Report NREL/TP-7A20-51294 September 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Contract No. DE-AC36-08GO28308 National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Technical Report NREL/TP-7A20-51294 September 2011 Integrating Renewable Energy into the Transmission and Distribution System of the

233

Development of a thyristor valve for next generation 500kV HVDC transmission systems  

SciTech Connect (OSTI)

A high voltage thyristor valve is the basic component of an HVDC transmission system. Development of a 500kV valve for next generation HVDC transmission systems is described. First, the power loss of the valve is analyzed to decide a reasonable wafer size for the light triggered thyristor. From these results, a six inch diameter wafer size is selected. The light triggered thyristor, with ratings of 8kV and 3.5kA, is developed using the six inch wafer. The designing of the valve employing the thyristor and test results with the prototype valve prove that a 500kV valve can be realized by the design method.

Hasegawa, T. [Kansai Electric Power Co., Inc., Osaka (Japan)] [Kansai Electric Power Co., Inc., Osaka (Japan); Yamaji, K. [Shikoku Electric Power Co., Inc., Takamatsu (Japan)] [Shikoku Electric Power Co., Inc., Takamatsu (Japan); Irokawa, H. [Electric Power Development Co., Ltd., Tokyo (Japan)] [Electric Power Development Co., Ltd., Tokyo (Japan); Shirahama, H.; Tanaka, C.; Akabane, K.

1996-10-01T23:59:59.000Z

234

Enhanced Geothermal Systems (EGS) with CO2 as Heat Transmission Fluid  

Open Energy Info (EERE)

with CO2 as Heat Transmission Fluid with CO2 as Heat Transmission Fluid Geothermal Lab Call Project Jump to: navigation, search Last modified on July 22, 2011. Project Title Enhanced Geothermal Systems (EGS) with CO2 as Heat Transmission Fluid Project Type / Topic 1 Laboratory Call for Submission of Applications for Research, Development and Analysis of Geothermal Technologies Project Type / Topic 2 Supercritical Carbon Dioxide / Reservoir Rock Chemical Interactions Project Description Previous and current attempts to develop EGS in the U.S., Japan, Europe and Australia have all employed water as a heat transmission fluid. Water has many properties that make it a favorable medium for heat extraction, but it also has serious drawbacks. The use of supercritical CO2 (scCO2) instead of water as heat extraction fluid was suggested by Donald Brown of Los Alamos National Laboratory as a "game changing" alternative that can avoid the problems of aqueous fluids, make heretofore inaccessible energy resources available for human use, and provide ancillary benefits by using and storing CO2.

235

A robust coordinated control scheme for HVDC transmission with parallel AC systems  

SciTech Connect (OSTI)

This paper introduces a practical control philosophy for HVDC transmission in parallel operation to an AC system with particular emphasis on coordination of both transient and dynamic stability. Systematic development of the control scheme on the basis of on-line identification, optimal control and rule-based bang-optimal coordination principles is presented. Verification tests of the scheme on a physical HVDC/AC system simulator show that the simple control computer algorithm is practical and robust. The controller can successfully distinguish between different system fault severities and adapts its output signals to provide maximum synchronizing torque and ensure optimal damping of power oscillations.

To, K.W.V.; David, A.K. (Hong Kong Polytechnic (Hong Kong). Dept. of Electrical Engineering); Hammad, A.E. (N.E. Swiss Power Co., Baden (Switzerland))

1994-07-01T23:59:59.000Z

236

Gasification Workshop  

Science Journals Connector (OSTI)

The workshop was organised to discuss why so many gasifier projects have failed throughout the world in the last few decades. The reasons offered are economic, technical, institutional and social, but there is st...

T. B. Reed; T. R. Miles Jr.

1988-01-01T23:59:59.000Z

237

Natural gas transmission and distribution model of the National Energy Modeling System  

SciTech Connect (OSTI)

The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of Integrated Analysis and Forecasting of the Energy Information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. From 1982 through 1993, the Intermediate Future Forecasting System (IFFS) was used by the EIA for its analyses, and the Gas Analysis Modeling System (GAMS) was used within IFFS to represent natural gas markets. Prior to 1982, the Midterm Energy Forecasting System (MEFS), also referred to as the Project Independence Evaluation System (PIES), was employed. NEMS was developed to enhance and update EIA`s modeling capability by internally incorporating models of energy markets that had previously been analyzed off-line. In addition, greater structural detail in NEMS permits the analysis of a broader range of energy issues. The time horizon of NEMS is the midterm period (i.e., through 2015). In order to represent the regional differences in energy markets, the component models of NEMS function at regional levels appropriate for the markets represented, with subsequent aggregation/disaggregation to the Census Division level for reporting purposes.

NONE

1997-02-01T23:59:59.000Z

238

2009 National Electric Transmission Congestion Study - Oklahoma City  

Broader source: Energy.gov (indexed) [DOE]

Oklahoma Oklahoma City Workshop 2009 National Electric Transmission Congestion Study - Oklahoma City Workshop On June 18, 2008, DOE hosted a regional pre-study workshop in Oklahoma City, OK to receive input and suggestions concerning the 2009 National Electric Transmission Congestion Study. The agenda, full transcript, and documents submitted for consideration for the 2009 study are available below. 6-18-08 Congestion Workshop Agenda - Oklahoma City, OK.pdf Transcript - 2009 National Electric Transmission Congestion Study Oklahoma City Workshop.pdf Independent Market Monitor Monthly Market Metrics Report, May 2008, submitted at 2009 Congestion Study Oklahoma City workshop.pdf Comments of the Missouri Public Service Missouri Commission, submitted at 2009 Congestion Study Oklahoma City workshop.pdf

239

(DOE/EIS-0285/SA-37): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 1/17/03  

Broader source: Energy.gov (indexed) [DOE]

17, 2002 17, 2002 REPLY TO ATTN OF: KEPR/Covington SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-37) Don Atkinson - TFN/Snohomish Bob Sweet - TFNF/Snohomish Proposed Action: Vegetation Management along the Monroe-Custer No.1 Transmission Line ROW from 29/1+915 to 45/4+975. The transmission line is 500 kV single circuit transmission line. Project includes adjacent Monroe-Custer No.2 and Arlington-Bellingham single circuit transmission lines having a combined ROW width of 421.5 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor. Location: The ROW is located in Snohomish and Skagit Counties, WA. Proposed by: Snohomish Regional Headquarters, Bonneville Power Administration (BPA).

240

(DOE/EIS-0285/SA-37): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 1/17/03  

Broader source: Energy.gov (indexed) [DOE]

17, 2002 17, 2002 REPLY TO ATTN OF: KEPR/Covington SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-37) Don Atkinson - TFN/Snohomish Bob Sweet - TFNF/Snohomish Proposed Action: Vegetation Management along the Monroe-Custer No.1 Transmission Line ROW from 29/1+915 to 45/4+975. The transmission line is 500 kV single circuit transmission line. Project includes adjacent Monroe-Custer No.2 and Arlington-Bellingham single circuit transmission lines having a combined ROW width of 421.5 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor. Location: The ROW is located in Snohomish and Skagit Counties, WA. Proposed by: Snohomish Regional Headquarters, Bonneville Power Administration (BPA).

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

ICAM Workshop | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

ICAM Workshop ICAM Workshop DOE ICAM Workshop 43.pdf More Documents & Publications Radio and Spectrum Management Ad Hoc Meetings PKI...

242

Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1  

SciTech Connect (OSTI)

The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. Subsequent chapters of this report provide: an overview of NGTDM; a description of the interface between the NEMS and NGTDM; an overview of the solution methodology of the NGTDM; the solution methodology for the Annual Flow Module; the solution methodology for the Distributor Tariff Module; the solution methodology for the Capacity Expansion Module; the solution methodology for the Pipeline Tariff Module; and a description of model assumptions, inputs, and outputs.

NONE

1998-01-01T23:59:59.000Z

243

Analysis of operations and cyber security policies for a system of cooperating Flexible Alternating Current Transmission System (FACTS) devices.  

SciTech Connect (OSTI)

Flexible Alternating Current Transmission Systems (FACTS) devices are installed on electric power transmission lines to stabilize and regulate power flow. Power lines protected by FACTS devices can increase power flow and better respond to contingencies. The University of Missouri Rolla (UMR) is currently working on a multi-year project to examine the potential use of multiple FACTS devices distributed over a large power system region in a cooperative arrangement in which the FACTS devices work together to optimize and stabilize the regional power system. The report describes operational and security challenges that need to be addressed to employ FACTS devices in this way and recommends references, processes, technologies, and policies to address these challenges.

Phillips, Laurence R.; Tejani, Bankim; Margulies, Jonathan; Hills, Jason L.; Richardson, Bryan T.; Baca, Micheal J.; Weiland, Laura

2005-12-01T23:59:59.000Z

244

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-70)  

Broader source: Energy.gov (indexed) [DOE]

(8-89) memorandum DATE: 7/19/02 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-70) Bill Erickson - TFP/Walla Walla Natural Resource Specialist TO: Proposed Action: Vegetation Management on sections of the McNary-Ross, McNary-Horse Heaven, Horse Heaven-Harvarlum, Harvarlum-Big Eddy, and Hanford-John Day Transmission lines. The treatment areas are identified in Step 1 of the Planning Steps shown below. The work will involve the control of noxious weeds in the subject rights-of-ways (ROWs). Location: The ROWs are located in Umatilla and Sherman Counties, Oregon and Benton and Klickitat Counties, Washington, all being in the Walla Walla and Redmond Regions.

245

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-42)  

Broader source: Energy.gov (indexed) [DOE]

5, 2002 5, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-42) Don Atkinson - TFN/Snohomish Bob Sweet - TFNF/Snohomish Proposed Action: Vegetation Management along the Snohomish - Murray #1 from str 1\4 to str 18\5. The proposed work will be to remove both danger and reclaim trees outside and inside the right-of-way, respectively. Right-of-way width varies from 125 to 300 feet. Location: The ROW is located in Snohomish County, WA, being in the Snohomish Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to remove both reclaim and danger trees inside and outside the transmission line right of way. BPA crews or contract crews will cut only trees that have

246

Integrating Renewable Energy into the Transmission and Distribution System of the U.S. Virgin Islands  

Broader source: Energy.gov (indexed) [DOE]

Integrating Renewable Energy Integrating Renewable Energy into the Transmission and Distribution System of the U.S. Virgin Islands Kari Burman, Dan Olis, Vahan Gevorgian, Adam Warren, and Robert Butt National Renewable Energy Laboratory Peter Lilienthal and John Glassmire HOMER Energy LLC Technical Report NREL/TP-7A20-51294 September 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Contract No. DE-AC36-08GO28308 National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Technical Report NREL/TP-7A20-51294 September 2011 Integrating Renewable Energy into the Transmission and

247

Montana-to-Washington Transmission System Upgrade Project - M2W  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

an existing BPA transmission line, and the proposed addition of a new series compensation substation along other existing BPA transmission lines. To understand the potential...

248

Active Shooter Training Workshop  

Broader source: Energy.gov [DOE]

The training workshop was based on real-world threats and issues and included a variety of guest lecturers and hands-on practical exercises. Participants utilized both live fire and engagement simulation system weaponry. The exercises were led by NTC instructors at the NTCs Live Fire Range and Integrated Safety and Security Training and Evaluation Complex (ISSTEC).

249

JMLR: Workshop and Conference Proceedings 1: 112-121 Machine Learning in Systems Biology Event based text mining for integrated network construction  

E-Print Network [OSTI]

JMLR: Workshop and Conference Proceedings 1: 112-121 Machine Learning in Systems Biology Event one step further, and use machine learning techniques com- bined with text mining to extract a much) or machine 1. http://pubmed.gov c 2010 Saeys et al.. #12;Event based text mining learning methods have been

Gent, Universiteit

250

A distributed on-line HV transmission condition monitoring information system  

SciTech Connect (OSTI)

China Light and Power Company Ltd. (CLP) is responsible for supplying electricity to the whole of Hong Kong except Hong Kong Island and Lamma Island. In CLP`s Castle Peak power plant, 19 kV and 23 kV electric supplies are generated. The voltage is then stepped up to 400 kV for transmission. The intermediate control between those transformers and the major 400 kV overhead transmission system lies with a standard One and a half Breaker Configuration switch substations. The substation houses single phase encapsulated SF{sub 6} circuit breakers. In the urban centers, 400 kV substations are installed to step down 400 kV to 132 kV or further to 11 kV for distribution. This paper describes the development of a on-line distributed information system for monitoring the conditions of the whole HV transmission system. The system continuously monitors status of each circuit breaker (CB) together with important operational parameters, such as duration during making and breaking, operations of hydraulic pumps and SF{sub 6} gas pressure etc. Each group of CBs is monitored by a standalone microcontroller using a local area network with a baud rate of 9,600. The information can be recorded on the harddisk of an on-site microcomputer and further transmitted back to a remote computer for alarm generation and multi-station supervision. The CLP 400 kV substation and the Tsz Wan Shan 400 kV substation are among the first targets for development.

Chan, W.L. [Hong Kong Polytechnic Univ., Kowloon (Hong Kong)] [Hong Kong Polytechnic Univ., Kowloon (Hong Kong); Pang, S.L.; Chan, T.M. [China Light and Power Co. Ltd., Hong Kong (Hong Kong)] [China Light and Power Co. Ltd., Hong Kong (Hong Kong); So, A.T.P. [City Univ. of Hong Kong, Kowloon (Hong Kong)] [City Univ. of Hong Kong, Kowloon (Hong Kong)

1997-04-01T23:59:59.000Z

251

Magnetohydrodynamic electromagnetic pulse (MHD-EMP) interaction with power transmission and distribution systems  

SciTech Connect (OSTI)

This report discusses the effects of the late-time high-altitude electromagnetic pulse (HEMP) on electrical transmission and distribution (T&D) systems. This environment, known as the magnetohydrodynamic electromagnetic pulse (MHD-EMP), is a very slowly varying electric field induced in the earth`s surface, similar to the field induced by a geomagnetic storm. It can result in the flow of a quasi-dc current in grounded power lines and in the subsequent magnetic saturation of transformers. This saturation, in turn, causes 6-Hz harmonic distortion and an increase in the reactive power required by generation facilities. This report analyzes and discusses these phenomena. The MHD-EMP environment is briefly discussed, and a simplified form of the earth-induced electric field is developed for use in a parametric study of transmission line responses. Various field coupling models are described, and calculated results for the responses of both transmission- and distribution-class power lines are presented. These calculated responses are compared with measurements of transformer operation under dc excitation to infer the MHD-EMP response of these power system components. It is found that the MHD-EMP environment would have a marked effect on a power system by inducing up to several hundreds of amperes of quasi-dc current on power lines. These currents will cause transformers to saturate which could result in excessive harmonic generation, voltage swings, and voltage suppression. The design of critical facilities which are required to operate during and after MHD-EMP events will have to be modified in order to mitigate the effects of these abnormal power system conditions.

Tesche, F.M. [Tesche (F.M.), Dallas, TX (United States); Barnes, P.R. [Oak Ridge National Lab., TN (United States); Meliopoulos, A.P.S. [Georgia Inst. of Tech., Atlanta, GA (United States). Dept. of Electrical Engineering

1992-02-01T23:59:59.000Z

252

An integrated multivariate approach for performance assessment and optimisation of electricity transmission systems  

Science Journals Connector (OSTI)

This article introduces an integrated approach based on data envelopment analysis (DEA) and principal component analysis (PCA) for efficiency assessment, and optimisation in transmission systems that have been responsible for the transmission of electricity in Iran to show its applicability and superiority. Performance of 16 regional electricity companies was evaluated using the non-parametric technique of DEA. The result indicates that the performance of several companies is sub-optimal, suggesting the potential for significant cost reduction and reduction in employee number. The optimisation procedure in this article is followed from two different viewpoints, i.e. input efficiency and -cost. The result of DEA model is verified and validated by PCA through Spearman correlation experiment. Moreover, the proposed approach uses the measure-specific super-efficiency DEA model for sensitivity analysis to determine the critical inputs based on efficiency and cost allocation super-efficiency DEA model to determine the critical inputs based on cost. The unique feature of this study is utilisation of DEA model for assessment and determination of critical inputs and optimisation for the critical inputs from two different viewpoints, i.e. input-efficiency and -cost. This is the first study that introduces a total approach for performance assessment and optimisation of electricity transmission companies.

Ali Azadeh; Somayeh Ahmadi Movaghar

2010-01-01T23:59:59.000Z

253

Certification and Listing Process and Procedures Workshop  

Broader source: Energy.gov [DOE]

Slides from the U.S. Department of Energy Hydrogen Component and System Qualification Workshop held November 4, 2010 in Livermore, CA.

254

CSA International Certification Discussion Hydrogen Technology Workshop  

Broader source: Energy.gov [DOE]

Slides from the U.S. Department of Energy Hydrogen Component and System Qualification Workshop held November 4, 2010 in Livermore, CA.

255

Comparison of reliability performance of group connected and conventional HVDC transmission systems  

SciTech Connect (OSTI)

A group connected HVDC transmission scheme is a variant of the unit connection where instead of a single generator, a group of generators are directly connected to the converter. Studies conducted in the past indicated that significant cost reduction can be achieved using this scheme. This is mainly due to the elimination of many components which results in considerable capital and operating cost savings to the utility. Concerns regarding the reliability performance of unit connected schemes were raised, however, there has not been a detailed reliability study conducted. This paper addresses the reliability evaluation aspect of a group connected scheme and compares the reliability performance of the group connected scheme with that of the conventional common collector system. Reliability models for both schemes were developed using a hypothetical system model based on the Nelson River system. Practical system component outage data was used to examine the reliability performance of both schemes.

Kuruganty, S. [Univ. of North Dakota, Grand Forks, ND (United States). Dept. of Electrical Engineering] [Univ. of North Dakota, Grand Forks, ND (United States). Dept. of Electrical Engineering

1995-10-01T23:59:59.000Z

256

MacroMacro--SystemSystem--Model Overview:Model Overview: DOE H2 Analysis WorkshopDOE H2 Analysis Workshop  

E-Print Network [OSTI]

Cell Cost Models Vehicle Selection Model Gasoline Vehicle Cost Models Environmental Performance Model to analyze components and subsystems of an eventual hydrogen economy, a modeling architecture does not exist that addresses the overarching hydrogen fuel infrastructure as a "system." Such a macro-system model is critical

257

Minimization of the vibration transmission through the propeller?shafting system in a submarine  

Science Journals Connector (OSTI)

Ships and submarines are efficient sources of underwater radiated noise. In the low?frequency range the main sources of ship vibration and noise are the working machinery such as the diesel engines gearboxes and generators and the propeller/propulsion system. Rotation of the propeller results in discrete tonals at the blade passing frequency and its harmonics. In addition in the case of a submarine hydrodynamic forces acting on the propeller due to the fluctuating pressure field are transmitted through the propeller?shaft and thrust bearings resulting in axial excitation of the submarine hull. A hydraulic dynamic absorber also known as a resonant changer is used to minimize the vibration transmission through the propeller?shafting system in order to prevent excitation of the hull axial resonances. The present work is concerned with minimizing the vibration transmission to the hull by optimizing the virtual spring mass and damper parameters associated with the resonant changer in a submarine. The dynamic response of the propeller?shafting system including the propeller shaft thrust bearing thrust block foundation and resonant changer are characterized using four pole parameters.

2004-01-01T23:59:59.000Z

258

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA 150 East Ellensburg Tap  

Broader source: Energy.gov (indexed) [DOE]

5, 2003 5, 2003 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA 150 East Ellensburg Tap Tom Murphy Natural Resource Specialist - TFS/Bell-1 Proposed Action: Vegetation Management for the East Ellensburg Tap, 1/6 to 3/19 Transmission Line ROW. The line is a 115 kV Single Circuit Transmission Line with no easement width. The proposed work will be accomplished in the indicated sections of the transmission line corridor. Location: The ROW is located in Kittatas County, WA being in the Spokane Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to clear unwanted vegetation in the rights-of-ways and around transmission line structures that may impede the operation and maintenance of the

259

(DOE/EIS-0285/SA-127): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 2/19/03  

Broader source: Energy.gov (indexed) [DOE]

KEP/4 KEP/4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-127- Eugene-Alvey#2 Benjamin Tilley - TFE/Alvey Proposed Action: Vegetation Management for the Eugene-Alvey 115 kV transmission line from structure 7/1 through structure 12/2m, and along portions of the following adjacent transmission lines: Hawkins-Alvey 115KV and Alvey-Lane 115KV. Location: The project is located in the BPA Eugene Region in Lane County, Oregon. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of- way, access roads, and around tower structures of the subject transmission line corridor that may impede the operation and maintenance of the identified transmission lines. BPA plans to

260

(DOE/EIS-0285-SA-100): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 8/15/02  

Broader source: Energy.gov (indexed) [DOE]

5, 5, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-100) Joe Johnson Natural Resource Specialist TFS/Kalispell Proposed Action: Vegetation Management along the Libby-Conkelly, 1/2 to 26/4 Transmission Line ROW. The line is a 230kV Double Circuit Transmission Line having an easement width of 125 feet to 250 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor. Location: The ROW is located in both Lincoln and Flathead County, MT, being in the Spokane Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-ways and around tower structures that may impede the operation and maintenance of the subject transmission line. All work will be in

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-34) (12/3/01)  

Broader source: Energy.gov (indexed) [DOE]

3, 2001 3, 2001 REPLY TO ATTN OF: KEP/Z992 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-34) Bill Erickson - TFP/Walla Walla Jim Jellison - TFO/Olympia Proposed Action: Vegetation Management along the McNary-Ross Transmission Line ROW between 152/3+2120 to 153/4. The line is 345 kV Single Circuit Transmission Line (project includes adjacent N. Bonneville-Ross 230 kV Single Circuit Transmission Line) having a combined easement width of 300 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor. Location: The ROW is located in Skamania County, WA, being in the Olympia Region. Proposed by: Bonneville Power Administration (BPA).

262

Linkages between demand-side management and congestion in the European electricity transmission system  

Science Journals Connector (OSTI)

Abstract We evaluate the possibility to reduce congestion in the transmission grid through large-scale implementation of demand-side management (DSM) in the form of load shifting for the EU-27 countries, Norway, and Switzerland for Year 2020. A linear, cost-minimising, dispatch model that includes a DC load-flow description of the transmission system and a general representation of load shifting is used. It is assumed that the EU Member States fulfil the targets for Year 2020 in their national renewable energy action plans. In the model calculations, a reference case without load shifting is compared with cases in which the load shifting is 5%, 10%, 15% or 20% of the load. The possibility to shift load in time is added exogenously and economic incentives for DSM are not evaluated. Three types of congestion are identified: peak-load-hour congestion, low-load-hour congestion and all-hour congestion. Peak-load-hour congestion is reduced as the DSM share of the load increases, whereas low-load-hour congestion, which is typically associated with a high level of wind generation, persists at all the DSM penetration levels investigated. We show that all-hour congestion occurs between systems that have large differences in supply structure, and that the impact of DSM on all-hour congestion is low.

Lisa Gransson; Joel Goop; Thomas Unger; Mikael Odenberger; Filip Johnsson

2014-01-01T23:59:59.000Z

263

Harmonic measurements made on the upgraded New Zealand inter-island HVdc transmission system  

SciTech Connect (OSTI)

This paper introduces the recent upgrade to the New Zealand inter-island HVdc transmission system. It then details the procedure of one of several tests conducted to measure harmonic levels created by the upgraded transmission system. Harmonic levels were measured using the CHART (Continuous Harmonic Analysis in Real-Time) harmonic monitoring instrumentation. The connection of CHART to the high voltage network and its configuration during the test is discussed. A sample of results gathered while monitoring are presented, including characteristic harmonics of the converter, and maximum voltage and current levels up to the 50th harmonic for each of the three a.c. phases. During the tests one of the two a.c. harmonic filters was switched out to observe its effect on harmonic levels. It was found that with both a.c. harmonic filters operating, most harmonic levels were lower than with only one filter operating. However some harmonic levels, namely the 4th harmonic, were larger with both filters operating. The paper is concluded with a discussion of the results and of the difficulties encountered in measuring harmonics of very low level.

Miller, A.J.V.; Dewe, M.B. (Univ. of Canterbury, Christchurch (New Zealand))

1994-07-01T23:59:59.000Z

264

UNDERSTANDING METHANE EMISSIONS SOURCES AND VIABLE MITIGATION MEASURES IN THE NATURAL GAS TRANSMISSION SYSTEMS: RUSSIAN AND U.S. EXPERIENCE  

SciTech Connect (OSTI)

This article will compare the natural gas transmission systems in the U.S. and Russia and review experience with methane mitigation technologies in the two countries. Russia and the United States (U.S.) are the world's largest consumers and producers of natural gas, and consequently, have some of the largest natural gas infrastructure. This paper compares the natural gas transmission systems in Russia and the U.S., their methane emissions and experiences in implementing methane mitigation technologies. Given the scale of the two systems, many international oil and natural gas companies have expressed interest in better understanding the methane emission volumes and trends as well as the methane mitigation options. This paper compares the two transmission systems and documents experiences in Russia and the U.S. in implementing technologies and programs for methane mitigation. The systems are inherently different. For instance, while the U.S. natural gas transmission system is represented by many companies, which operate pipelines with various characteristics, in Russia predominately one company, Gazprom, operates the gas transmission system. However, companies in both countries found that reducing methane emissions can be feasible and profitable. Examples of technologies in use include replacing wet seals with dry seals, implementing Directed Inspection and Maintenance (DI&M) programs, performing pipeline pump-down, applying composite wrap for non-leaking pipeline defects and installing low-bleed pneumatics. The research methodology for this paper involved a review of information on methane emissions trends and mitigation measures, analytical and statistical data collection; accumulation and analysis of operational data on compressor seals and other emission sources; and analysis of technologies used in both countries to mitigate methane emissions in the transmission sector. Operators of natural gas transmission systems have many options to reduce natural gas losses. Depending on the value of gas, simple, low-cost measures, such as adjusting leaking equipment components, or larger-scale measures, such as installing dry seals on compressors, can be applied.

Ishkov, A.; Akopova, Gretta; Evans, Meredydd; Yulkin, Grigory; Roshchanka, Volha; Waltzer, Suzie; Romanov, K.; Picard, David; Stepanenko, O.; Neretin, D.

2011-10-01T23:59:59.000Z

265

Record of Decision for the Transmission System Vegetation Management Program (DOE/EIS-0285) (07/00)  

Broader source: Energy.gov (indexed) [DOE]

SYSTEM VEGETATION SYSTEM VEGETATION MANAGEMENT PROGRAM Record of Decision DOE/EIS-0285 Cooperating Agencies J U L Y 2 0 0 0 Bonneville Power Administration Transmission System Vegetation Management Program Record of Decision Table of Contents Summary of Decision .................................................................................................................................... 1 For Further Information .............................................................................................................................. 2 Background ................................................................................................................................................... 3 Decisions ........................................................................................................................................................

266

(DOE/EIS-0285/SA-41): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 2/27/02  

Broader source: Energy.gov (indexed) [DOE]

February 27, 2002 February 27, 2002 REPLY TO ATTN OF: KEPR-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-41) William Erickson - TPF/Walla Walla Natural Resource Specialist Proposed Action: Vegetation Management around wood poles in Transmission Line ROW's in the Walla Walla Region (see attached checklist for identification). The proposed work will be accomplished in the indicated sections of the transmission line corridors with the easement width ranging from 0 to 200 feet. Location: The ROWs are located in Walla Walla Region (see checklist). Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation around

267

Photovoltaics performance and reliability workshop  

SciTech Connect (OSTI)

This document consists of papers and viewgraphs compiled from the proceedings of a workshop held in September 1992. This workshop was the fifth in a series sponsored by NREL/DOE under the general subject areas of photovoltaic module testing and reliability. PV manufacturers, DOE laboratories, electric utilities and others exchanged technical knowledge and field experience. The topics of cell and module characterization, module and system performance, materials and module durability/reliability research, solar radiation, and applications are discussed.

Mrig, L. (ed.) [ed.

1992-01-01T23:59:59.000Z

268

Renewable Electricity Futures Study. Volume 4: Bulk Electric Power Systems: Operations and Transmission Planning  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Bulk Electric Power Systems: Bulk Electric Power Systems: Operations and Transmission Planning Volume 4 of 4 Volume 2 PDF Volume 3 PDF Volume 1 PDF Volume 4 PDF NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Renewable Electricity Futures Study Edited By Hand, M.M. National Renewable Energy Laboratory Baldwin, S. U.S. Department of Energy DeMeo, E. Renewable Energy Consulting Services, Inc. Reilly, J.M. Massachusetts Institute of Technology Mai, T. National Renewable Energy Laboratory Arent, D. Joint Institute for Strategic Energy Analysis Porro, G. National Renewable Energy Laboratory Meshek, M. National Renewable Energy Laboratory Sandor, D. National Renewable

269

Calculation of transmission system losses for the Taiwan Power Company by the artificial neural network with time decayed weight  

SciTech Connect (OSTI)

For energy conservation and improvement of power system operation efficiency, how to reduce the transmission system losses becomes an important topic of grave concern. To understand the cause, and to evaluate the amount, of the losses are the prior steps to diminish them. To simplify the evaluation procedure without losing too much accuracy, this paper adopts the artificial neural network, which is a model free network, to analyze the transmission system losses. As the artificial neural network with time decayed weight has the capability of learning, memorizing, and forgetting, it is more suitable for a power system with gradually changing characteristics. By using this artificial neural network, the estimation of transmission system losses will be more precise. In this paper, comparison will be made between the results of artificial neural network analysis and polynomial loss equations analysis.

Chu, W.C.; Chen, B.K.; Mo, P.C. [Tatung Inst. of Tech., Taipei (Taiwan, Province of China)

1995-12-31T23:59:59.000Z

270

Interactions between frequencydependent and vertical transmission in hostparasite systems  

Science Journals Connector (OSTI)

...frequency-dependent transmission to the total number...population over time. Solid line represents susceptible...fected via horizontal route and dot-dash-dot line is hosts infected via...coexistence when ver- tical transmission is possible. Including...

1997-01-01T23:59:59.000Z

271

EIS-0484: Montana-to-Washington Transmission System Upgrade Project in Washington, Idaho, and Montana  

Broader source: Energy.gov [DOE]

This EIS will evaluate the environmental impacts of a proposal to replace roughly 12 miles of transmission line on the Taft-Dworshak 500-kV transmission line, install new series capacitors on the Garrison-Taft 500-kV transmission line, and perform various upgrades to Bell, Hatwai, Dworshak, Garrison, and Hot Springs substations.

272

OBSERVERS BASED SYNCHRONIZATION AND INPUT RECOVERY FOR A CLASS OF CHAOTIC SYSTEMS. APPLICATION TO IMAGE TRANSMISSION  

E-Print Network [OSTI]

TO IMAGE TRANSMISSION Estelle Cherrier, , Jos´e Ragot , CRAN UMR 7039 / Nancy-Universit´e, CNRS 2 Avenue transmission as an application of a chaotic cryptosystem. The underlying problem concerns nonlinear state on the message. Efficiency of the proposed approach is shown through an image transmission. 1. INTRODUCTION

Boyer, Edmond

273

State of the art analysis of online fault location on AC cables in underground transmission systems  

E-Print Network [OSTI]

, such as 400 kV transmission lines, will also be undergrounded gradually as more experience is gath- ered of underground cables for the transmission level. In Denmark, as a leading country, the entire 150 kV and 132 kV on transmission level fault location methods have been focused on overhead lines. Because of the very different

Bak, Claus Leth

274

Probabilistic Approach to Quantifying the Contribution of Variable Generation and Transmission to System Reliability: Preprint  

SciTech Connect (OSTI)

The increasing electrical load served by variable generation (VG), such as wind and solar energy, in the United States and many other countries has stimulated an interesting line of research to better quantify the capacity value of these resources. Methods applied traditionally to thermal units based on their average outage rates do not apply to VG because of their uncertain and non-dispatchable nature. The North American Electric Reliability Corporation's Integration of Variable Generation Task Force recently released a report that highlighted the need to develop and benchmark underlying loss-of-load expectation and related metrics that reasonably and fairly calculate the contribution to planning reserves, or capacity value, of solar and wind power. As the fraction of generation coming from VG becomes more significant, their estimated capacity value will have a larger impact on system planning. In this paper, we provide a method to include VG in traditional probabilistic-based adequacy methods. This method has been implemented in the Renewable Energy Probabilistic Resource Assessment tool developed at the National Renewable Energy Laboratory. Through an example based on the U.S. Western Interconnection, this method is applied to assess the effect that transmission can have on resource adequacy. We also analyze the interactions between available transmission and capacity value for VG.

Ibanez, E.; Milligan, M.

2012-09-01T23:59:59.000Z

275

Supplement Analysis for the Transmission System Vegetation Management Program FEIS DOE/EIS-0285/SA-08  

SciTech Connect (OSTI)

Clearing C-trees along the south side of the right-of-way. This project meets the standards and guidelines for the Transmission System Vegetation Management Program Final Environmental Impact Statement (FEIS) and Record of Decision (ROD). The project involves controlling all tall growing trees (C-Trees) within the right-of-way. All work is to be done on the south side of centerline. Target vegetation is the tall growing Firs along the edge of the ROW, all of which is located within the back yards of the property owners along the right-of-way. The density of vegetation is low and consists of C-Trees located within backyards, with the branches growing towards the lines. Due to lack of access and past verbal agreements with the landowners, permission/agreement has been difficult to obtain from the property owners. Permission has now been obtained to remove the C-Trees within their back yards which, will soon be a hazard to our transmission line facility. We are working with the landowners to get them to plant low growing scrubs and ornamentals within the right-of-way and adjacent to the right-of-way. A follow up herbicide treatment is not planned because the trees being cut will not re-sprout. This right-of-way or project area is on a three to four year maintenance schedule. Little or no treatment should be required in the immediate future.

N /A

2001-04-23T23:59:59.000Z

276

Customer system efficiency improvement assessment: Supply curves for transmission and distribution conservation options  

SciTech Connect (OSTI)

This report documents the results of Task 6 in the Customer System Efficiency Improvement (CSEI) Assessment Project. A principal objective of this project is to assess the potential for energy conservation in the transmission and distribution (TandD) systems of electric utilities in the BPA service area. The scope of this assessment covers BPA customers in the Pacific Northwest region and all non-federal TandD systems, including those that currently place no load on the BPA system. Supply curves were developed to describe the conservation resource potentially available from TandD-system efficiency improvements. These supply curves relate the levelized cost of upgrading existing equipment to the estimated amount of energy saved. Stated in this form, the resource represented by TandD loss reductions can be compared with other conservation options and regional electrical generation resources to determine the most cost-effective method of supplying power to the Pacific Northwest. The development of the supply curves required data acquisition and methodology development that are also described in this report. 11 refs., 11 figs., 16 tabs.

Tepel, R.C.; Callaway, J.W.; De Steese, J.G.

1987-11-01T23:59:59.000Z

277

Hydrogen Safety Sensors Workshop  

Broader source: Energy.gov [DOE]

A DOE-sponsored workshop was held in Washington, DC on April 4, 2007 with approximately 50 experts from industry, government, national laboratories, and universities. The workshop included...

278

SSL Market Development Workshop  

Broader source: Energy.gov [DOE]

SSL Market Development Workshop Nov 12-13The 2014 DOE SSL Market Development Workshop gathers perspectives from government, industry, cities, utilities, designers, specifiers, retailers,...

279

NEET Workshop 2010  

Broader source: Energy.gov [DOE]

The Nuclear Energy Enabling Technologies Workshop Report was held in Rockville, MD on July 29, 2010. DOEs primary purposes in convening the NEET workshop were to:

280

Workshop Registration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Workshop Registration Workshop Registration Workshop Registration If you had previously registered for the cancelled October 2013 event, you must submit a new registration for the July 2014 event. Registration Form Last Name: First Name: Institution: Position: Mailing Address: Office Phone Number: Fax: Mobile Number: Email Address: Badging: I have a regular DOE Badge I do not have a regular DOE Badge and will need a Visitor Badge If you are a US citizen and do not have a DOE badge, bring a photo ID. If you are not a US citizen, contact Heath Garrison for more information. EFCOG Member: Is your company a member of EFCOG? If you are not sure, check the website. Yes No If you answered No to the above, were you invited by the Electrical Safety Subgroup Chair? Yes No Note: If you were not invited by the Subgroup Chair, do not submit your registration until you contact Greg Christensen, Idaho - Chair (208-526-5380) for approval to attend.

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

(DOE/EIS-0285/SA-120): Supplement Analysis for the Transmission System Vegetation Management Program FEISq 2/10/03  

Broader source: Energy.gov (indexed) [DOE]

0, 2003 0, 2003 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-120 Hanford-Ostrander Corridor Maintenance William Erickson TFP/Walla Walla Natural Resource Specialist Proposed Action: Vegetation Management for the Hanford-Ostrander Transmission Line Corridor from Tower 10/4 to Tower 17/2 + 770. The line is a 500kV Single Circuit Transmission Line having an easement width of 300 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor as referenced on the attached checklist. Location: The subject right-of-way is located in Benton County, WA. In the Walla Walla Region. Proposed by: Bonneville Power Administration (BPA).

282

(DOE/EIS-0285/SA-119): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 1/29/03  

Broader source: Energy.gov (indexed) [DOE]

9, 2003 9, 2003 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-119 Snohomish-Murray No. 1 Transmission Line Don Atkinson - TFN/Snohomish Proposed Action: Vegetation Management along the Snohomish-Murray No. 1 Transmission Line from structure 2/6 through structure 18/6. Right of way width is 95 feet. Location: The project area is located within Snohomish County, Washington. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of- way, access roads and around tower structures along the subject transmission line corridor. Total right-of-way acreage is approximately 182.8 acres. Approximately 17 miles of access roads will

283

(DOE/EIS-0285/SA-122): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 2/19/03  

Broader source: Energy.gov (indexed) [DOE]

CSB-2 CSB-2 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-122- Bonneville-Alcoa Ed Tompkins, TFO/LMT Proposed Action: Vegetation Management for the Bonneville-Alcoa 115kV transmission line Location: The project is located in the BPA Olympia Region in Skamania and Clark Counties, Washington. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of- way, along access roads and around tower structures along the subject transmission line corridor that may impede the operation and maintenance of the identified transmission lines. All work will be in accordance with the National Electrical Safety Code and BPA standards. BPA plans

284

(DOE/EIS-0285/SA=32): Supplement Analysis for the Transmission System Vegetation Management Program FEIS (11/15/01)  

Broader source: Energy.gov (indexed) [DOE]

November 15, 2001 November 15, 2001 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285-SA-32) Bill Erickson - TPF/Walla Walla Natural Resource Specialist Proposed Action: Re-vegetation Plot Study along the Lower Monumental-McNary Transmission Line ROW. The study area sections are located near structures 38/4 and 39/3. The line is a 500kV Single Circuit Transmission Line having an easement width of 165 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor as indicated on the attached checklist. Location: The ROW is located in Walla Walla County, WA being in the Walla Walla Region. Proposed by: Bonneville Power Administration (BPA).

285

(DOE/EIS-0285/SA-57): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 4/10/02  

Broader source: Energy.gov (indexed) [DOE]

0, 2002 0, 2002 REPLY TO ATTN OF: KEP/Z992 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-57) Jim Jellison - TFO/Olympia Proposed Action: Vegetation Management along the Trojan-Allston Transmission Lines 1 & 2 ROW between 1/1 and 9/1. The lines are 230 kV Single Circuit Transmission Lines having an easement width of 125 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor. Location: The ROW is located in Columbia County, OR, being in the Olympia Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of- ways and around tower structures that may impede the operation and maintenance of the subject

286

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-20)(8/2/01)  

Broader source: Energy.gov (indexed) [DOE]

2, 2001 2, 2001 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-20) Bill Erickson - TFP/Walla Walla - Natural Resource Specialist Jim Jellison - TFO/Olympia - Natural Resource Specialist Proposed Action: Vegetation Management along the McNary-Ross 161/1 to 166/5+346 Transmission Line ROW. The line is a 345kV Single Circuit Transmission Line having an easement width of 175 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor. Location: The ROW is located in Clark County, WA, being in the Olympia Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-ways

287

DOE/EIS-0285-SA-62: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (4/16/02)  

Broader source: Energy.gov (indexed) [DOE]

DATE April 16, 2002 REPLY TO ATTN OF: KEPR/Covington SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-62) Don Atkinson - TFN/Snohomish Proposed Action: Vegetation Management along the Rocky Reach - Maple Valley No. 1 Transmission Line ROW from structure 98/2 to structure 110/1. The transmission line is a 500 kV line. Location: The ROW is located King County, WA. Proposed by: Snohomish Regional Headquarters, Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear targeted vegetation along access roads and around tower structures that may impede the operation and maintenance of the subject transmission line. BPA plans to conduct vegetation management along existing access road and

288

(DOE/EIS-0285-126): Supplement Analysis for the Transmission System Vegetation Management Program 2/19/03  

Broader source: Energy.gov (indexed) [DOE]

KEP-4 KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-126- Alvey Fairview Benjamin Tilley - TFE/Alvey Proposed Action: Vegetation Management for the Alvey Fairview 230kV transmission line from structure 1/1 through structure 64/7. Location: The project is located in the BPA Eugene Region in Coos, Douglas, and Lane Counties, Oregon. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of- way, along access roads and around tower structures along the subject transmission line corridor that may impede the operation and maintenance of the identified transmission lines. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently

289

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285-SA-33)(11/27/01)  

Broader source: Energy.gov (indexed) [DOE]

November 27, 2001 November 27, 2001 REPLY TO ATTN OF: KEP/Z992 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS- 0285/SA-33) Bill Erickson - TFP/Walla Walla Jim Jellison - TFO/Olympia Proposed Action: Vegetation Management along the St Helens-Allston Transmission Line ROW. The line is a 115 kV Single Circuit Transmission Line having an easement width of 100 feet. Location: The ROW is located in Columbia County, OR, being in the Olympia Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear danger trees from varying widths of the indicated transmission line right-of-way that are approaching electrical clearance zones in accordance

290

(DOE/EIS-0285/SA-105): Supplement Analysis for the Transmission System Vegetation Management Program FEIS (08/22/02)  

Broader source: Energy.gov (indexed) [DOE]

2, 2, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA 105 Elbe Tap to Alder-LaGrande No. 1 James Jellison - TFO/Olympia Proposed Action: Vegetation Management along the Elbe Tap to Alder-LaGrande No.1 and 115kV transmission line from structure 1/1 through structure 7/17. Corridor width varies. The project area is located within Whatcom County, Washington. Location: Transmission line is located at and west of Elbe, Pierce County Washington. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of-way, access roads and around tower structures along the subject transmission line corridor. The right-of-way will be treated using selective and non-selective methods that include hand cutting, mowing

291

(DOE/EIS-0285/SA-55): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 4/12/02  

Broader source: Energy.gov (indexed) [DOE]

2, 2002 2, 2002 REPLY TO ATTN OF: KEPR/Covington SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-55) Don Atkinson - TFN/Snohomish Proposed Action: Vegetation Management along the Raver - Paul No. 1 Transmission Line ROW from structure 15/5 to 29/3. The transmission line is a 500 kV line. Location: The ROW is located Pierce County, WA. Proposed by: Snohomish Regional Headquarters, Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of- ways and around tower structures that may impede the operation and maintenance of the subject transmission line, including both Reclaim and Danger Trees. Also, access road clearing will be

292

Technical Workshop: Resilience Metrics for Energy Transmission...  

Energy Savers [EERE]

Metrics J. Mark Drexel Presentation: Risk Assessment for Storm Hardening Anders Johnson Presentation: Natural Gas Transportation Resiliency Christina Sames Presentation:...

293

Hydrogen Infrastructure Market Readiness Workshop: Preliminary Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Hydrogen Infrastructure Market Readiness Hydrogen Infrastructure Market Readiness Workshop: Preliminary Results Marc Melaina, PhD Hydrogen Technologies and Systems Center, NREL Distributed electronically to workshop attendees for review March 24, 2011 Goal of this presentation * This presentation is being disseminated to workshop attendees to convey the aggregate and "raw" feedback collected during the workshop * This feedback will be compiled in a final report * We would like to accomplish two things with these slides: 1. Share the preliminary results with participants 2. Get your feedback now on any corrections or omissions * We are still open to receiving additional feedback on the workshop topic, but will report it as having been received outside of the workshop if it is included in the final report

294

High-power microwave transmission systems for electron-cyclotron-resonance plasma heating  

SciTech Connect (OSTI)

This progress report is for the sixth year of a grant from the US Department of Energy for the design, development, and fabrication of ECRH transmission and mode conversion systems to transport microwave power from a gyrotron to a magnetically confined plasma. The design and low-power testing of new and improved components for such systems and development of underlying theory is the focus of this project. Devising and improving component testing and diagnostic techniques is also an important part of this effort. The development of possible designs for sections of gyrotrons themselves, such as tapers or Vlasov-type launchers, in support of the Varian gyrotron development program is also considered when appropriate. We also provide support to other groups working on ECR heating of magnetically confined plasmas such as the groups at General Atomics, the University of Texas at Austin, and Lawrence Livermore National Laboratory. During the last year, we designed and had fabricated a two-dimensional Vlasov antenna system for a 110 GHz TE{sub 15,2} mode gyrotron for possible use at General Atomics. The system included the launcher section, a visor, main reflector, and focusing reflector. Programs to generate the tool-path profiles to cut the General Atomics'' Vlasov components on a milling machine were developed. We have also developed state-of-the art theory and programs for three-dimensional whispering-gallery-mode Vlasov antenna systems. A design for a 110 GHz TE{sub 01}-TE{sub 15,2} mode converter system for cold testing WGM Vlasov antenna systems was developed and is currently being fabricated also.

Vernon, R.J.

1991-08-01T23:59:59.000Z

295

Microsoft Word - HVDC Workshop Agenda - Final  

Broader source: Energy.gov (indexed) [DOE]

US Department of Energy's Grid Tech Team US Department of Energy's Grid Tech Team hosts Applications for High-Voltage Direct Current Transmission Technologies April 22, 2013 NRECA Conference Center 4301 Wilson Blvd. Arlington, VA 22203 Objective This workshop is aimed at developing a better understanding of the potential for High Voltage Direct Current (HVdc) transmission technologies and its application in the North American electric grid. Through a series of case studies and group discussions, DOE would like to identify the state-of-the-art for HVdc transmission technologies, including performance and benefits. The workshop will also discuss technical and institutional barriers to greater deployment and possible opportunities to address those barriers. Background The advantages of HVdc transmission over conventional High Voltage Alternating Current

296

2014 International Workshop on Grid Simulator Testing  

Broader source: Energy.gov [DOE]

The National Renewable Energy Laboratory (NREL) and Clemson University will host the second International Workshop on Grid Simulator Testing of Energy Systems and Wind Turbine Powertrains at the Duke Energy Electric Grid Research, Innovations and Development Center at 1253 Supply Street, North Charleston, South Carolina. The purpose of the workshop is to discuss the research and testing needs involved in grid compliance testing of utility-scale wind turbine generators. Information regarding the workshop can be found at: http://www.nrel.gov/esi/pdfs/201406_egrid_workshop_flyer.pdf.

297

Training: Process Heating Systems | Department of Energy  

Office of Environmental Management (EM)

Process Heating System Assessment - 1-day workshop Availability: Onsite instructor-led and online self-paced workshop This workshop provides an introduction to process...

298

Development of a surface conductivity measurement system for ultrahigh vacuum transmission electron microscope  

SciTech Connect (OSTI)

The surface conductivity measurement system using a micro-four-point probe (M4PP) had been developed for the ultrahigh vacuum transmission electron microscope (UHV-TEM). Since the current distribution in the sample crystals during the current voltage measurement by the M4PP is localized within the depth of several micrometers from the surface, the system is sensitive to the surface conductivity, which is related with the surface superstructure. It was installed in the main chamber of the TEM and the surface conductivity can be measured in situ. The surface structures were observed by reflection electron microscopy and diffraction (REM-RHEED). REM-RHEED enables us to observe the surface superstructures and their structure defects such as surface atomic steps and domain boundaries of the surface superstructure. Thus the effects of the defects on the surface conductivity can be investigated. In the present paper we present the surface conductivity measurement system and its application to the Si(111)-{radical}(3)x{radical}(3)-Ag surface prepared on the Si(111) vicinal surfaces. The result clearly showed that the surface conductivity was affected by step configuration.

Minoda, H. [Department of Applied Physics, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi, Saitama 332-0012 (Japan); Hatano, K.; Yazawa, H. [Department of Applied Physics, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 (Japan)

2009-11-15T23:59:59.000Z

299

Evaluation of power system security and development of transmission pricing method.  

E-Print Network [OSTI]

??The electric power utility industry is presently undergoing a change towards the deregulated environment. This has resulted in unbundling of generation, transmission and distribution services. (more)

Kim, Hyungchul

2004-01-01T23:59:59.000Z

300

Critical Materials Workshop  

Broader source: Energy.gov [DOE]

Presentations during the Critical Materials Workshop held on April 3, 2012 overviewing critical materials strategies

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Kyoto Workshop  

Broader source: Energy.gov (indexed) [DOE]

Center for Reliable Electric Power Transmission Center for Reliable Electric Power Transmission Alan Mantooth, University of Arkansas 1 1 National Center for Reliable Electric Power Transmission A Center for Advanced Power Electronics Dr. H. Alan Mantooth, Director Dr. Simon Ang, Associate Director Dr. Juan Carlos Balda, Associate Director Dr. Roy McCann, Associate Director University of Arkansas - Fayetteville http://ncrept.eleg.uark.edu Silicon Carbide Research for Reliable Electric Power: Design and Test National Center for Reliable Electric Power Transmission Alan Mantooth, University of Arkansas 2 Research advanced power electronic solutions for grid- connected applications Fault currents continue to rise in urban centers and the use of FCLs provides an attractive way to extend the useful life of

302

DOE/EIS-0285; Bonneville Power Administration Transmission System Vegetation Management Program Final Environmental Impact Statement (May 2000)  

Broader source: Energy.gov (indexed) [DOE]

Statement Statement DOE/EIS-0285 Arrow-leaf Balsamroot Cooperating Agencies Bonneville Power Administration Transmission System Vegetation Management Program Final Environmental Impact Statement (DOE/EIS-0285) Responsible Agency: Bonneville Power Administration (Bonneville), U.S. Department of Energy Cooperating Agencies: U.S. Forest Service (FS), U.S. Department of Agriculture; Bureau of Land Management (BLM), U.S. Department of Interior Title of Proposed Action: Transmission System Vegetation Management Program States Involved: California, Idaho, Montana, Oregon, Utah, Washington, and Wyoming Abstract: Bonneville is responsible for maintaining a network of 24,000 kilometers (km) or 15,000 miles (mi.) of electric transmission lines and 350 substations in a region of diverse vegetation.

303

Microsoft Word - APS_workshop_Final.doc  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

REPORT of the Workshop on the Role of Synchrotron Radiation in Solving Scientific Challenges in Advanced Nuclear Energy Systems January 27 and 28, 2010 Advanced Photon Source Argonne National Laboratory April 2010 iii CONTENTS EXECUTIVE SUMMARY ......................................................................................................... v INTRODUCTION ....................................................................................................................... 1 Workshop Background .......................................................................................................... 1 Representation from Interest Groups ..................................................................................... 2 BREAKOUT SESSION SUMMARIES...................................................................................... 3

304

Workshop to Assess Innovative Solutions to Transportation  

E-Print Network [OSTI]

Workshop to Assess Innovative Solutions to Transportation Needs in the Colonias Workshop Summary SWUTC/04/167151-1 Texas Transportation Institute Texas A&M University System College Station, Texas 77843-3135 Center for HUD's Colonias Program Southwest Region University Transportation Center #12

305

National Transmission Grid Study  

Broader source: Energy.gov (indexed) [DOE]

Grid Study Grid Study U.S. Department of Energy The Honorable Spencer Abraham Secretary of Energy May 2002 ii National Transmission Grid Study National Transmission Grid Study i ii National Transmission Grid Study National Transmission Grid Study iii How This Study Was Conducted The National Energy Policy Plan directed the U.S. Department of Energy (DOE) to conduct a study to examine the benefits of establishing a national electricity transmission grid and to identify transmission bottlenecks and measures to address them. DOE began by conducting an independent analysis of U.S. electricity markets and identifying transmission system bottlenecks using DOE's Policy Office Electricity Modeling System (POEMS). DOE's analysis, presented in Section 2, confirms the central role of the nation's transmission

306

Abstract--As a common tendency, large-scale wind farms are increasingly connected to the transmission system of modern  

E-Print Network [OSTI]

stability I. INTRODUCTION arge-scale wind power plants are increasingly integrated into the transmission regulation. For variable-speed wind turbines which are connected to the power system through power electronic convertors, one advantage is that the output active power and reactive power can be controlled separately

Chen, Zhe

307

Single x-ray transmission system for bone mineral density determination  

SciTech Connect (OSTI)

Bones are the support of the body. They are composed of many inorganic compounds and other organic materials that all together can be used to determine the mineral density of the bones. The bone mineral density is a measure index that is widely used as an indicator of the health of the bone. A typical manner to evaluate the quality of the bone is a densitometry study; a dual x-ray absorptiometry system based study that has been widely used to assess the mineral density of some animals' bones. However, despite the success stories of utilizing these systems in many different applications, it is a very expensive method that requires frequent calibration processes to work properly. Moreover, its usage in small species applications (e.g., rodents) has not been quite demonstrated yet. Following this argument, it is suggested that there is a need for an instrument that would perform such a task in a more reliable and economical manner. Therefore, in this paper we explore the possibility to develop a new, affordable, and reliable single x-ray absorptiometry system. The method consists of utilizing a single x-ray source, an x-ray image sensor, and a computer platform that all together, as a whole, will allow us to calculate the mineral density of the bone. Utilizing an x-ray transmission theory modified through a version of the Lambert-Beer law equation, a law that expresses the relationship among the energy absorbed, the thickness, and the absorption coefficient of the sample at the x-rays wavelength to calculate the mineral density of the bone can be advantageous. Having determined the parameter equation that defines the ratio of the pixels in radiographies and the bone mineral density [measured in mass per unit of area (g/cm{sup 2})], we demonstrated the utility of our novel methodology by calculating the mineral density of Wistar rats' femur bones.

Jimenez-Mendoza, Daniel; Vargas-Vazquez, Damian [Division de Investigacion y Posgrado, Facultad de Ingenieria, Universidad Autonoma de Queretaro, Cerro de las Campanas s/n., C.P. 76010, Queretaro, Qro. (Mexico); Espinosa-Arbelaez, Diego G. [Posgrado en Ciencia e Ingenieria en Materiales, Instituto de Investigaciones en Materiales, Universidad Nacional Autonoma de Mexico, Av. Universidad 3000, C.P. 04510, Coyoacan, Mexico D.F. (Mexico); Departamento de Nanotecnologia, Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico, Campus Juriquilla, Boulevard Juriquilla 3001, C.P. 76230, A.P. 1-1010, Juriquilla, Qro. (Mexico); Giraldo-Betancur, Astrid L. [Centro de Investigacion y de Estudios Avanzados del Instituto Politecnico Nacional, Libramiento Norponiente 2000, C.P. 76230, Fracc. Real de Juriquilla, Qro. (Mexico); Hernandez-Urbiola, Margarita I. [Posgrado en Investigaciones Biomedicas, Universidad Nacional Autonoma de Mexico, Campus Juriquilla, Boulevard Juriquilla 3001, C.P. 76230, A.P. 1-1010, Juriquilla, Qro. (Mexico); Departamento de Nanotecnologia, Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico, Campus Juriquilla, Boulevard Juriquilla 3001, C.P. 76230, A.P. 1-1010, Juriquilla, Qro. (Mexico); Rodriguez-Garcia, Mario E. [Departamento de Nanotecnologia, Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico, Campus Juriquilla, Boulevard Juriquilla 3001, C.P. 76230, A.P. 1-1010, Juriquilla, Qro. (Mexico)

2011-12-15T23:59:59.000Z

308

E-Print Network 3.0 - air system workshop Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Storage, Conversion and Utilization 11 inAir: Measuring and Visualizing Indoor Air Quality Sunyoung Kim & Eric Paulos Summary: visualization to be more user-intuitive. SYSTEM...

309

2007 Nanoelectronics Workshop Summary  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Nanoelectronics Nanoelectronics Co-Organizers: Mark Eriksson, University of Wisconsin-Madison Nikolai Zhitenev, Bell Laboratories The workshop addressed some of the fundamental issues concerning the incorporation of organic and inorganic building blocks as electronic, optical, and mechanical components into nano- and/or mesoscopic devices and systems and their electronic and structural characterization. The materials ranged from short organic molecules and monolayers of macromolecules, to carbon nanotubes, to semiconductors and superconductors. In the keynote presentation, Surprio Datta (Purdue University) reviewed the modern conceptual framework for understanding quantum transport in nanodevices. Prof. Datta highlighted approaches applicable to both equilibrium systems,

310

(DOE/EIS-0285/SA-36): Supplement Analysis for the Transmission System Vegetation Management Program FEIS (01/22/02)  

Broader source: Energy.gov (indexed) [DOE]

24, 2002 24, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-38) Benjamin J. Tilley - TFE/Alvey Proposed Action: Vegetation Management along the Wendson-Tahkenith #1 & #2 1/1-20/4, Tahkenitch-Gardiner #1/1-2/3 and Tahkenitch-Reedsport #1/1-4/2 Transmission Line ROW's. The proposed work will be accomplished in the indicated sections of the transmission line corridor with and average corridor width of 100 feet. Location: The ROW is located in Douglas and Lane County, OR, being in the Eugene Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-ways

311

(DOE/EIS-0285/SA-43): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 2/27/02  

Broader source: Energy.gov (indexed) [DOE]

February 27, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-43) William T. Erickson - TFP/Walla Walla Natural Resource Specialist Proposed Action: Vegetation Management along the Lower Monumental - McNary 57/2 to 63/5, and Radar Tap 0/4 to 0/10 Transmission Line ROW's. The proposed work will be accomplished in the indicated sections of the transmission line corridor with and average corridor width of 165 and 80 feet respectively. Location: The ROW is located in Umatilla and Franklin County, OR, being in the Walla Walla Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-ways

312

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-28)(9/5/01)  

Broader source: Energy.gov (indexed) [DOE]

September 5, 2001 September 5, 2001 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-28) James Jellison - TFO/Olympia Natural Resource Specialist Proposed Action: Vegetation Management along the Port Angeles - Sappo No.1 Transmission Line ROW, from struture 1/1 to structure 42/10. Location: The ROW is located in Clallum County, WA, all in the Olympia Region. Proposed by: Bonneville Power Administration (BPA), Olympia Region. Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-ways and around tower structures that may impede the operation and maintenance of the subject transmission line. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is

313

(DOE/EIS-0285/SA-75): Supplement Analysis for the Transmission System Vegetation Management Program FEIS (06/21/02)  

Broader source: Energy.gov (indexed) [DOE]

June June 21, 2002 REPLY TO ATTN OF: KEP/Z-992 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA- 75-Ross-Lexington. Jim Jellison -- - TFO/Olympia Ed Tompkins -- - TFO/Ross Proposed Action: Vegetation Management for the Ross Lexington Transmission Line. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove danger trees as well as unwanted vegetation in the rights-of-ways, along access roads and around tower structures that may impede the operation and maintenance of the subject transmission line. See Section 1.4 of the attached checklist for a complete description of the proposed action. Analysis: Please see the attached checklist for the resources present. Applicable findings and mitigation measures are discussed below. Planning Steps: 1. Identify facility and

314

(DOE/EIS-0285/SA-103): Supplemental Analysis for Transmission System Vegetation Management Program FEIS (August 12, 2002)  

Broader source: Energy.gov (indexed) [DOE]

2, 2, 2002 REPLY TO ATTN OF: KEP/Z992 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-103-Keeler-Pennwalt). Jim Jellison - TFO/Olympia Ed Tompkins - TFO/Ross Proposed Action: Vegetation Management for the Keeler-Pennwalt transmission line and parts of the St. John-Keeler, Rivergate-Keeler, Keeler-Oregon City, & St. John-St. Helens lines. Location: Washington and Multnomah Counties, Oregon Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to clear targeted vegetation within the Right-of-Ways along access roads and around tower structures that may impede the operation and maintenance of the subject transmission line. See Section 1.4 of the attached checklist for a complete description of the proposed action. Analysis: See the attached checklist for the

315

(DOE/EIS-0285/SA-59): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 4/19/02  

Broader source: Energy.gov (indexed) [DOE]

April 19, 2002 April 19, 2002 REPLY TO ATTN OF: KEP SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-59) James Jellison - TFO/Olympia Natural Resource Specialist Proposed Action: Vegetation Management along the Chehalis Covington/ Raver Paul / Paul Alston 230 and 500 kV Transmission line Corridor ROW 48/2 to 70/6 and 1/1 to 13/4. The proposed work will be accomplished in the indicated sections of the transmission line corridor with a corridor width of 250 to 442 feet. Location: The ROW is located in Thurston County, WA, being in the Olympia Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-ways

316

(DOE/EIS-0285/SA-02): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 3/9/01  

Broader source: Energy.gov (indexed) [DOE]

3/09/01 3/09/01 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-02) Bill Erickson - TFP/Walla Walla Natural Resource Specialist Proposed Action: Danger tree clearing on nine ROWs. Locations are: the Franklin-Badger Canyon #2; Hedges Tap; White Bluffs-Richland; Grandview-Richland; Badger Canyon-Richland; Franklin- Riverview; Taylor Flats Tap; Walla Walla-Pendleton; and McNary-Slatt Transmission lines. Location: All ROWs are located in the Walla Walla Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear danger trees from varying widths of the indicated transmission line rights-of way that are approaching electrical clearance zones in

317

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-22)(8/17/01)  

Broader source: Energy.gov (indexed) [DOE]

August 17, 2001 August 17, 2001 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-22) Donald F. Atkinson - TFN/Snohomish Natural Resource Specialist Proposed Action: Vegetation Management along the Chief Joseph - Snohomish No.3 and 4 Transmission Line ROW. From STR 94/1 to STR 113/1 Location: The ROW is located in King and Snohomish Counties, WA, in the Snohomish Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-ways and around tower structures that may impede the operation and maintenance of the subject transmission line. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is

318

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-23)(8/17/01)  

Broader source: Energy.gov (indexed) [DOE]

DATE: August 17, 2001 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-23) Donald F. Atkinson - TFN/Snohomish Natural Resource Specialist Proposed Action: Vegetation Management along the Schultz - Raver No.1 and 2 from 60/3 to 75/5 and the Olympia - Grand Coulee from 70/2 to 70/5 Transmission Line ROW's. Location: The ROW is located in King County, WA, in the Snohomish Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-ways, around tower structures, and along access roads that may impede the operation and maintenance of the subject transmission line. All work will be executed in accordance with the National Electrical Safety

319

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-26)(9/11/01)  

Broader source: Energy.gov (indexed) [DOE]

11, 2001 11, 2001 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-26) Ben Tilley - TFE/Alvey Natural Resource Specialist Proposed Action: Vegetation Management on Reedsport-Fairview #1 Transmission Line Structure 1/5 to 39/4. Location: All ROW are located in Coos and Douglas Counties, OR, all being in the Eugene Region. Proposed by: Bonneville Power Administration (BPA), Eugene Region. Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-ways and around tower structures that may impede the operation and maintenance of the subject transmission line. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently

320

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-17)(7/24/01)  

Broader source: Energy.gov (indexed) [DOE]

DATE: July 24, 2001 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-17) Donald F. Atkinson - TFN/Snohomish Natural Resource Specialist Proposed Action: Vegetation Management along selected sections of the Schulz - Raver No.1, 2, 3 & 4, Olymplia - Grand Coulee NO. 1 Transmission Line ROW's. Location: The ROW's are located in Pierce and King Counties, WA, in the Snohomish Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-ways and around tower structures that may impede the operation and maintenance of the subject transmission line. All work will be executed in accordance with the National Electrical Safety Code and BPA

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

NREL: Systems Engineering - 2015 Wind Energy Systems Engineering...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Systems Engineering Wind Research Systems Engineering Printable Version 2015 Wind Energy Systems Engineering Workshop The third NREL Wind Energy Systems Engineering Workshop will...

322

Workshop Purpose  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

7454 7454 Science Challenges and Design Concepts for the Next-Generation High-Performance FT-ICR Mass Spectrometer Summary of a workshop held January 16-17, 2008 at the National High Magnetic Field Laboratory, Tallahassee, Florida Jean H. Futrell Alan G. Marshall David W. Koppenaal Ljiljana Paša-Tolić Julie G. Wiley Organized by the National High Magnetic Field Laboratory and Environmental Molecular Sciences Laboratory Sponsored by the National Science Foundation and the U.S. Department of Energy 1 Introduction Mass spectrometry (MS) is among the most sensitive, molecule-specific, and generally applicable analytical techniques currently available. Although there are many important performance metrics, the mass resolving power of an analytical mass spectrometer is the ultimate

323

Catalysis Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Opportunities in Catalysis Research Using Synchrotron Radiation Opportunities in Catalysis Research Using Synchrotron Radiation Stanford Synchrotron Radiation Laboratory October 8-9, 2002 Organizer: Anders Nilsson Chemical catalysis is one of the research areas of enormous importance for the industrial society. There are important challenges to be met in the near future where development of new processes and catalysts are a necessity. We need to find a way to make methanol from methane, split water into hydrogen using sunlight, find replacement of platinum metals, etc. The fundamental understanding of many catalytic processes is still emerging and there seems to be a new opportunity with the recent development in experimental and theoretical methods. The intention of workshop was to bring researchers from many different disciplines together to discuss how synchrotron radiation can be applied to address some fundamental questions in catalysis.

324

A high speed image transmission system for ultra-wideband wireless links  

E-Print Network [OSTI]

Ultra-wideband (UWB) communication is an emerging technology that offers short range, high data rate wireless transmission, with low power consumption and low consumer cost. Operating in the 3.1 GHz - 10.6 GHz frequency ...

Liang, Helen He

2009-01-01T23:59:59.000Z

325

Effects of un-transposed UHV transmission line on fault analysis of power systems  

Science Journals Connector (OSTI)

The conventional fault analysis method based on symmetrical components supposes that the three-phase parameters of un-transposed transmission line are symmetrical in case of fault. The errors caused by the method...

Anning Wang ???; Qing Chen ? ?; Zhanping Zhou ???

2008-06-01T23:59:59.000Z

326

Transmission | Open Energy Information  

Open Energy Info (EERE)

Gateway Gateway Edit History Facebook icon Twitter icon » Transmission (Redirected from Transmission) Jump to: navigation, search Transmission header.png Transmission Dashboard Permitting Atlas Compare States Arizona California Colorado Idaho Montana Nevada New Mexico Oregon Utah Washington Wyoming Resource Library NEPA Database Transmission Lattice.jpg High-voltage transmission lines form the backbone of electricity systems. Transmission lines are designed to carry large amounts of electricity at high voltages, typically 115 to 500 kilovolts (kV), across long distances. Networks of transmission lines transfer electricity from power plants or other interconnections to substations. At substations, the high-voltage electricity is "stepped down" to a lower voltage, which can be carried

327

California Energy Commission Public Interest Energy Research/Energy System Integration -- Transmission-Planning Research & Development Scoping Project  

E-Print Network [OSTI]

stakeholders in transmission-line route planning and sitingan optimal transmission line route-finding tool. This tool

Eto, Joseph H.; Lesieutre, Bernard; Widergren, Steven

2004-01-01T23:59:59.000Z

328

Nuclear Safety Workshop Summary  

Broader source: Energy.gov (indexed) [DOE]

Workshop Summary Workshop Summary September 19-20, 2012 1 Nuclear Safety Workshop Summary On September 19-20, 2012, the U.S. Department of Energy (DOE) held a second Nuclear Safety Workshop covering the results of the Department's actions to improve its posture for analyzing and responding to severe accidents in light of lessons learned from the March 2011 nuclear accident in Japan. Sponsored by DOE and championed by Deputy Secretary of Energy Daniel Poneman, the two-day workshop discussed the lessons learned in a national and international context. The workshop's theme

329

First International Workshop on Rack-scale Computing (WRSC 2014) The Case for the Holistic Language Runtime System  

E-Print Network [OSTI]

First International Workshop on Rack-scale Computing (WRSC 2014) The Case for the Holistic Language will be a rack-sized machine instead of an individual server. At the same time, we expect a shift from commodity. In this paper, we make the case that the software for such custom rack-scale machines should move away from

Asanovi?, Krste

330

International Energy Workshop, Cape Town, June 19-21, 2012 Power system and Carbon capture under Climate policy  

E-Print Network [OSTI]

2013 Author manuscript, published in "International Energy Workshop (IEW), Cap Town : South Africa, distribution, and trade of various energy forms and materials, and their end-uses. TIAM-FR is driven by end on equipment investment and operation, primary energy supply, and energy trade (Loulou and Labriet, 2007).TIAM

Boyer, Edmond

331

IPHE Infrastructure Workshop - Workshop Proceedings, February...  

Broader source: Energy.gov (indexed) [DOE]

station development. The workshop was sponsored by the International Partnership for Hydrogen and Fuel Cells in the Economy (IPHE), in cooperation with the California Fuel...

332

Quadrennial Technology Review Workshop Portfolios | Department...  

Broader source: Energy.gov (indexed) [DOE]

Review Workshop Portfolios Quadrennial Technology Review Workshop Portfolios Department of Energy Quadrennial Technology Review Building & Industrial Efficiency Workshop...

333

Quadrennial Technology Review Workshops | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Workshops Quadrennial Technology Review Workshops Department of Energy Quadrennial Technology Review Building & Industrial Efficiency Workshop Department of Energy Quadrennial...

334

DOE Solar Decathlon: 2007 Consumer Workshops  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

man presents information about energy-efficient buildings to a group of people seated under a canopy at the 2007 Solar Decathlon. man presents information about energy-efficient buildings to a group of people seated under a canopy at the 2007 Solar Decathlon. Workshops on energy efficiency and solar technologies drew large crowds during the 2007 Solar Decathlon. Solar Decathlon 2007 Consumer Workshops Below are descriptions of the consumer workshops offered at the 2007 Solar Decathlon. Energy Efficiency for the Homeowner Presenter: Lew Pratsch, DOE The workshop focuses on ways to reduce energy bills for new and older homes by discussing topics such as energy efficient mortgages and other resources. Solar for the Homeowner Presenter: Glenn Strahs, DOE Are you ready to add a system onto your home and enjoy the benefits of clean, quiet power whose cost will not increase over time? The workshop

335

Workshop for coordinating South Carolina`s pre-college systemic initiatives  

SciTech Connect (OSTI)

The goal of the South Carolina Statewide Systemic Initiative (SC SSI) is to provide quality and effective learning experiences in science and mathematics to all people of South Carolina by affecting systemic change. To accomplish this goal, South Carolina must: (1) coordinate actions among many partners for science and mathematics change; (2) place the instruments of change into the hands of the effectors of change - teachers and schools; and (3) galvanize the support of policy makers, parents, and local communities for change. The SC SSI proposes to establish a network of 13 regional mathematics and science HUBs. The central idea of this plan is the accumulation of Teacher Leaders at each HUB who are prepared in special Curriculum Leadership Institutes to assist other teachers and schools. The HUB becomes a regional nexus for delivering services to schools who request assistance by matching schools with Teacher Leaders. Other initiatives such as the use of new student performance assessments, the integration of instructional technologies into the curriculum, a pilot preservice program, and Family Math and Family Science will be bundled together through the Teacher Leaders in the HUBs. Concurrent policy changes at the state level in teacher and administrator certification and recertification requirements, school regulations and accountability, and the student performance assessment system will enable teachers and schools to support instructional practices that model South Carolina`s new state Curriculum Frameworks in Mathematics and Science.

NONE

1997-03-26T23:59:59.000Z

336

2012 Microgrid Workshop Summary Released | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

2012 Microgrid Workshop Summary Released 2012 Microgrid Workshop Summary Released 2012 Microgrid Workshop Summary Released September 13, 2012 - 2:22pm Addthis The Department of Energy has released the summary report from the July 30-31, 2012 Microgrid Workshop presented by the Office of Electricity Delivery and Energy Reliability at the Illinois Institute of Technology in Chicago. The workshop was held in response to discussions at the preceding DOE Microgrid Workshop, held in August 2011, which called for sharing lessons learned and best practices for system integration from existing projects in the U.S. (including military microgrids) and internationally. In addition, the purpose of the workshop was to determine system integration gap areas in meeting the DOE program 2020 targets for microgrids and to define specific R&D activities for the needed, but unmet,

337

2012 DOE Microgrid Workshop Summary Report (September 2012) | Department of  

Broader source: Energy.gov (indexed) [DOE]

DOE Microgrid Workshop Summary Report (September 2012) DOE Microgrid Workshop Summary Report (September 2012) 2012 DOE Microgrid Workshop Summary Report (September 2012) The July 30-31, 2012 Microgrid Workshop was presented by the Office of Electricity Delivery and Energy Reliability at the Illinois Institute of Technology in Chicago. The workshop was held in response to discussions at the preceding DOE Microgrid Workshop, held in August 2011, which called for sharing lessons learned and best practices for system integration from existing projects in the U.S. (including military microgrids) and internationally. An additional purpose of the workshop was to determine system integration gap areas in meeting the DOE program 2020 targets for microgrids and to define specific R&D activities for the needed, but unmet, functional

338

Alaska Workshop: Workforce Development  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy Office of Indian Energy is hosting two workshops at the Alaska Village Initiatives Rural Small Business Conference on Wednesday, February 12, 2014. Each workshop will...

339

EFRC Workshop Program  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Students Teacher Workshop July 12-15, 2010 Location: Horizon 1, USC Workshop planning led by Martha J. Reifsnider, EFRC Education and Outreach Director gsmjj@vt.edu, phone:...

340

IPHE Infrastructure Workshop Proceedings  

Fuel Cell Technologies Publication and Product Library (EERE)

This proceedings contains information from the IPHE Infrastructure Workshop, a two-day interactive workshop held on February 25-26, 2010, to explore the market implementation needs for hydrogen fuelin

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Hydrogen Compatible Materials Workshop  

Broader source: Energy.gov [DOE]

Summary of the Hydrogen Compatible Materials Workshop held November, 3, 2010, at Sandia National Laboratories in Livermore, California. Summary includes the workshop agenda, an overview of the morning presentations, a discussion of the afternoon meeting, and a list of participants.

342

SSRL29 Workshop Summaries  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Workshop Summaries X-ray Imaging and Spectro-microscopy: the Present and the Future< font> (Chairs: John Miao and Keith Hodgson) This workshop provided a forum to discuss the...

343

Ad Lucem Workshop Welcome  

Broader source: Energy.gov [DOE]

This presentation summarizes the information given by DOE during the DOE Ad Lucem workshop, Feb. 17, 2012.

344

Membrane Technology Workshop  

Broader source: Energy.gov [DOE]

Presentation by Charles Page (Air Products & Chemicals, Inc.) for the Membrane Technology Workshop held July 24, 2012

345

DOE/EIS-0285; Bonneville Power Administration Transmission System Vegetation Management Program Final Environmental Impact Statement (May 2000)  

Broader source: Energy.gov (indexed) [DOE]

Purpose, Need and Issues Purpose, Need and Issues S-1 Summary In this summary: ΠPurpose, Need, and Issues ΠMethods and Their Impacts ΠPlanning Steps ΠProgram Alternatives and Their Impacts Purpose, Need and Issues Bonneville Power Administration (Bonneville) is responsible for maintaining a network of 15,000 miles of electric transmission lines and 350 substations. This electric transmission system operates in seven states of the Pacific Northwest. (See Figure S-1.) Those states offer a great diversity of vegetation (from trees to brush to grasses), which can interfere with electric power flow, pose safety problems for us and neighboring members of the public, or interfere with our ability to maintain our system. We need to keep vegetation a safe distance away from our electric power facilities and control

346

(DOE/EIS-0285/SA-08): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 4/23/01  

Broader source: Energy.gov (indexed) [DOE]

23, 2001 23, 2001 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS DOE/EIS-0285/SA-08 Don Atkinson - TFN/Snohomish Natural Resource Specialist Proposed Action: Clearing C-trees along the south side of the right-of-way. Location: Raver - Covington Line 1, between towers 6/5 and 7/2. Work will be performed in the State of Washington. Proposed by: BPA Snohomish Region. Analysis: This project meets the standards and guidelines for the Transmission System Vegetation Management Program Final Environmental Impact Statement (FEIS) and Record of Decision (ROD). Planning Steps 1. Identify facility and the vegetation management need. The project involves controlling all tall growing trees (C-Trees) within the right-of-way. All

347

XANES Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Absorption Near-Edge Spectra in Analysis of Mixtures Absorption Near-Edge Spectra in Analysis of Mixtures Stanford Synchrotron Radiation Laboratory Wednesday, October 9, 2002 Orange Room, SLAC Organizers: Ingrid Pickering & Graham George A workshop on "X-ray Absorption Near-edge Spectra in Analysis of Mixtures" chaired by Ingrid Pickering (SSRL) and Graham George (SSRL) was held on October 9, 2002. X-ray absorption near-edge spectroscopy is a sensitive probe of local atomic environment, oxidation state and electronic structure, and can thus be used as a fingerprint of particular chemical environments. No special sample preparation is required and the incident x-rays probe a given element regardless of its physical form (solid, liquid or gaseous). Because of this, x-ray absorption near-edge spectroscopy can be a powerful method for analysis of chemical form in complex samples such as mixtures and has already found a wide range of applications. Least-squares fitting can be used to quantitatively determine the abundances of various chemical species in a mixture. In the case of a set of related mixtures, principal component analysis can be used to determine the number of individual components in the set, and target transformation can be used to test whether a given standard spectrum is one of the components.

348

Climate Change Workshop 2007  

E-Print Network [OSTI]

1 Climate Change Workshop 2007 Adaptive Management and Resilience Relevant for the Platte River, UNL Climate Change Workshop 2007 · Resilience ·Why it matters · Adaptive Management ·How it helps ·Adaptive Capacity · What it is Overview Climate Change Workshop 2007 "A public Domain, once a velvet carpet

Nebraska-Lincoln, University of

349

DOE Fuel Cell Pre-Solicitation Workshop - Breakout Group 3: HIGH...  

Broader source: Energy.gov (indexed) [DOE]

DOE Fuel Cell Pre-Solicitation Workshop - Breakout Group 3: HIGH TEMP (SOFC) SYSTEM AND BOP DOE Fuel Cell Pre-Solicitation Workshop - Breakout Group 3: HIGH TEMP (SOFC) SYSTEM AND...

350

SunShot Presentation PV Module Reliabity Workshop Opening Session  

Broader source: Energy.gov (indexed) [DOE]

2013 PV Module Reliability Workshop Feb 26- 27, 2013, Golden, CO * The SunShot Initiative * Systems Integration Technology Validation Activities * 2013 PV Module Reliability...

351

Proceedings of the National Hydrogen Energy Roadmap Workshop...  

Broader source: Energy.gov (indexed) [DOE]

Documents & Publications Proceedings of the Hydrogen Vision Meeting Proceedings of the Technology Roadmap Workshop on Communication and Control Systems for Distributed Energy...

352

GTT 2012 Distribution Workshop - Documents | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Distribution Workshop - Documents Distribution Workshop - Documents GTT 2012 Distribution Workshop - Documents Use the links below to download documents from the GTT's Distribution Workshop, held September 24-26, 2012 Agenda Roster of Attendees Presentation - Welcome and Introduction to the Grid Tech Team, Vision, and Framework - Anjan Bose, DOE Presentation - OE's Smart Grid ACtivities in the Distribution System - Patricia Hoffman, DOE Presentation - Electricity Distribution Systems - Allan Schurr, IBM Presentation - Power Electric Cooperatives, NRECA Presentation - Distribution System Research Priorities - Mark McGranaghan, EPRI Product - Compilation Slides from Technology-Specific Breakout Group Sessions Product - Compliation Slides from Various System-Perspective Breakout Teams Product - Final Discussion Summary Report

353

Transmission | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Gateway Edit History Facebook icon Twitter icon » Transmission Jump to: navigation, search Transmission header.png Transmission Dashboard Permitting Atlas Compare States Arizona California Colorado Idaho Montana Nevada New Mexico Oregon Utah Washington Wyoming Resource Library NEPA Database Transmission Lattice.jpg High-voltage transmission lines form the backbone of electricity systems. Transmission lines are designed to carry large amounts of electricity at high voltages, typically 115 to 500 kilovolts (kV), across long distances. Networks of transmission lines transfer electricity from power plants or other interconnections to substations. At substations, the high-voltage

354

Spring`07SeminarSeriesandWorkshopsSpring`07SeminarSeriesandWorkshops Coordinator: Prof. Jeff Moehlis, Moelis@engineering.ucsb.edu, 893-7513  

E-Print Network [OSTI]

Spring`07SeminarSeriesandWorkshopsSpring`07SeminarSeriesandWorkshops Coordinator: Prof. Jeff Moehlis, Moelis@engineering.ucsb.edu, 893-7513 Center for Control, Dynamical SystemsCenter for Control

Akhmedov, Azer

355

IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 16, NO. 4, NOVEMBER 2001 933 Discussion on "Review of Usage-Based Transmission Cost  

E-Print Network [OSTI]

of Usage-Based Transmission Cost Allocation Methods Under Open Access" Juan Zolezzi, Hugh Rudnick., IEEE Trans. Power Systems, vol. 15, no. 4, pp. 1218­1224, November 2000. Discussion of "Review of Usage comparing a variety of usage-based transmission charges. This discusser would like to make two points about

Catholic University of Chile (Universidad Católica de Chile)

356

IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS--II: EXPRESS BRIEFS, VOL. 55, NO. 9, SEPTEMBER 2008 927 Using Transmission Line Outage Data to  

E-Print Network [OSTI]

Using Transmission Line Outage Data to Estimate Cascading Failure Propagation in an Electric Power transmission line outages recorded over nine years in an electric power system with approx- imately 200 lines. The average amount of propagation of the line outages is estimated from the data. The distribution

Dobson, Ian

357

Coordination of Transmission Line Transfer Capabilities  

E-Print Network [OSTI]

Coordination of Transmission Line Transfer Capabilities Final Project Report Power Systems since 1996 PSERC #12;Power Systems Engineering Research Center Coordination of Transmission Line Summary The maximum power that can be transferred over any transmission line, called the transfer capacity

358

2012 Microgrid Workshop Report  

Broader source: Energy.gov (indexed) [DOE]

and Energy Reliability Smart Grid R&D Program Summary Report: 2012 DOE Microgrid Workshop July 30-31, 2012 Chicago, Illinois 2012 DOE Microgrid Workshop Report Page i Acknowledgment The U.S. Department of Energy (DOE) would like to acknowledge the support provided by the organizations represented on the workshop planning committee in developing the workshop process and sessions. The preparation of this workshop report was coordinated by Energy & Environmental Resources Group, LLC (E2RG). The report content is based on the workshop session discussions, with session summary descriptions taken from the report-out presentations by individual teams during the closing plenary. Contributions to this report by all workshop participants, via expressed viewpoints during the

359

Eastern Wind Integration and Transmission Study -- Preliminary Findings: Preprint  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

05 05 September 2009 Eastern Wind Integration and Transmission Study - Preliminary Findings Preprint D. Corbus, M. Milligan, and E. Ela National Renewable Energy Laboratory M. Schuerger Energy Systems Consulting Services B. Zavadil EnerNex Corp. To be presented at the 8th International Workshop on Large Scale Integration of Wind Power and on Transmission Networks for Offshore Wind Farms Bremen, Germany October 14-15, 2009 NOTICE The submitted manuscript has been offered by an employee of the Alliance for Sustainable Energy, LLC (ASE), a contractor of the US Government under Contract No. DE-AC36-08-GO28308. Accordingly, the US Government and ASE retain a nonexclusive royalty-free license to publish or reproduce the published form of this contribution, or allow others to do so, for US Government purposes.

360

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-25)(9/5/01)  

Broader source: Energy.gov (indexed) [DOE]

5, 2001 5, 2001 REPLY TO ATTN OF: KEP/Z992 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-25) Elizabeth Johnson - TFR/The Dalles Jim Jellison - TFO/Olympia Proposed Action: Vegetation Management along selected ROW sections of the Ostrander-Pearl transmission line. The ROWs include sections of the Ostrander-Pearl 500 kV line; the Ostrander-McLoughlin 500 kV line; the Big Eddy-Chemawa 230 kV line and the Big Eddy- McLoughlin 230 kV line. Location: The ROW is located in Clackamas County, Oregon, within the Olympia Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights- of-way and around tower structures that may impede the operation and maintenance of the

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

(DOE/EIS-0285/SA-04): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 3/27/01  

Broader source: Energy.gov (indexed) [DOE]

March 27, 2001 March 27, 2001 REPLY TO ATTN OF: KEC-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-04) Elizabeth Johnson - TFR/The Dalles Natural Resource Specialist Proposed Action: Vegetation Management on Ponderosa - Pilot Butte 18/2 to 18/4 Relocation Location: The project area is in the City of Bend, OR, in Deschutes County. Proposed by: Bonneville Power Administration Description of the Proposed Action: BPA proposes to clear unwanted vegetation from a section of BPA's Ponderosa - Pilot Butte Transmission Line Right-of-way to facilitate relocation of structure 18/3. Work would begin in mid-March and end in April, 2001. Analysis: 1. Description of right-of-way and vegetation management needed: The project involves

362

(DOE/EIS-0285/SA-52): Supplement Analysis for the Transmission System Vegetation Management Program FEIS (03/22/02)  

Broader source: Energy.gov (indexed) [DOE]

22, 2002 22, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-52) Elizabeth Johnson - TFR/The Dalles Natural Resource Specialist Proposed Action: Vegetation Management on the Ashe-Marion #2 (138/1-150/2), Buckley- Marion (12/1-24/2), McNary-Santiam (109/1-119/3), and John Day-Marion (49/4-50/5) Transmission Line Corridors. Location: The project area lies between Maupin and Pine Grove Oregon, and is in the Redmond Region. The project area begins at on the Ashe-Marion at structure 138/1 and terminates at Wapinitia Road, Pine Grove. Proposed by: Bonneville Power Administration. Description of the Proposed Action: BPA proposes to clear unwanted vegetation from the

363

(DOE/EIS-0285/SA-15): Supplement Analysis for the Transmission System Vegetation Manaement Program FEIS 6/19/01  

Broader source: Energy.gov (indexed) [DOE]

United States Government Department of Energy Bonneville Power Administration DATE: June 19, 2001 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-15) Jim Jellison - TFO/Olympia Natural Resource Specialist Proposed Action: Vegetation management on selected sections of ROWs in the Ross-St. John and Ross-Carborundum transmission line ROWs. The ROWs include sections of the Ross-St. John 230Kv line; the Ross-Rivergate 230Kv line; the Ross-Alcoa 115Kv line; the Ross-Carborundum 115Kv line and the Clark PUD 115Kv line. Location: The ROWs span sections of Vancouver Washington and Portland Oregon and are all

364

(DOE/EIS-0285/SA-07): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 4/18/01  

Broader source: Energy.gov (indexed) [DOE]

18, 2001 18, 2001 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-07) Bill Erickson - TFP/Walla Walla Natural Resource Specialist Proposed Action: Vegetation Management on section of three ROWs. The ROWs include selected sections of the McNary Powerhouse, the present and proposed new sections of the McNary-Roundup and the McNary Switchyard South Transmission lines. Location: All ROW are located east Umatilla, OR., all being in the Walla Walla Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of- ways and around tower structures that may impede the operation and maintenance of the subject

365

(DOE/EIS-0285/SA-123): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 2/20/03  

Broader source: Energy.gov (indexed) [DOE]

20, 2003 20, 2003 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-123 Malin-Hilltop Elizabeth Johnson - TFR/The Dalles Natural Resource Specialist Proposed Action: Vegetation Management on Malin-Hilltop (Structures 20/5-29/1). Location: The project area lies to the southeast of Klamath Falls, OR, and is located in Modoc County, California. Proposed by: Bonneville Power Administrationn (BPA) Description of the Proposed Action: Trees are located under and adjacent to conductors. Should a fire occur, these trees are a hazard to the line and could cause serious damage to the conductors, resulting in significant problems for the transmission grid. BPA plans on

366

Planning and processing of new or upgraded electric transmission systems in New Mexico  

SciTech Connect (OSTI)

RETA has been requested to identify and prioritize renewable energy resource zones in New Mexico that have a potential to support industry development among renewable energy developers for renewable resource generation projects. Moreover, Senate Memorial 44 requests that RETA identify and prioritize the best viable options for potential transmission corridors to accommodate renewable energy export from New Mexico in accordance with a defined time-line and to convene a working group to submit recommendations to the legislature for establishing a process to streamline procedures for establishing renewable energy transmission projects in New Mexico. RETA's July 9, 2009 request for comments outlined seven topical areas of specific value to Senate Memorial 44. This document addresses Topics 1, 3 and 4.

Toole, Gasper Loren [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

367

NREL: Energy Analysis: Transmission Infrastructure  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission Infrastructure Transmission Infrastructure Grid expansion and planning to allow large scale deployment of renewable generation Large scale deployment of renewable electricity generation will require additional transmission to connect renewable resources, which are wide-spread across the US, but regionally-constrained, to load centers. Long-term transmission planning, based on potential future growth in electric loads and generation resource expansion options, is critical to maintaining the necessary flexibility required for a reliable and robust transmission system. NREL's analyses support transmission infrastructure planning and expansion to enable large-scale deployment of renewable energy in the future. NREL's transmission infrastructure expansion and planning analyses show

368

Facility Representative Program: 2010 Facility Representative Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

10 Facility Representative Workshop 10 Facility Representative Workshop May 12 - 13, 2010 Las Vegas, NV Facility Rep of the Year Award | Attendees | Summary Report Workshop Agenda and Presentations Day 1: Wednesday, May 12, 2010 8:00 a.m. Opening Remarks James Heffner, Facility Representative Program Manager Earl Hughes, Safety System Oversight Program Manager Office of Nuclear Safety Policy and Assistance Office of Health, Safety and Security 8:15 a.m. Welcome from the Nevada Site Office John Mallin, Deputy Assistant Manager for Site Operations Nevada Site Office 8:30 a.m. Workshop Keynote Address Todd Lapointe Chief of Nuclear Safety Central Technical Authority Staff 9:15 a.m. Facility Representative and Safety System Oversight Award Ceremony James Heffner, Facility Representative Program Manager

369

Microgrid Workshop Report August 2011 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Microgrid Workshop Report August 2011 Microgrid Workshop Report August 2011 Microgrid Workshop Report August 2011 The U.S. Department of Energy (DOE) Office of Electricity Delivery and Energy Reliability (OE) held the Microgrid Workshop on August 30-31, 2011, in San Diego, California. The purpose of the workshop was to convene experts and practitioners to assist the DOE in identifying and prioritizing research and development (R&D) areas in the field of microgrids. The targets of the OE microgrid initiative are to develop commercial scale microgrid systems capable of reducing outage time of required loads by >98% while reducing emissions by >20% and improving system energy efficiencies by >20%, by 2020. Microgrid Workshop Report August 2011.pdf More Documents & Publications

370

Fuel Cell Technologies Office: Workshop and Meeting Proceedings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Workshop and Meeting Proceedings Workshop and Meeting Proceedings This page contains links to information from workshops and meetings funded by the U.S. Department of Energy Hydrogen and Fuel Cells Program. Hydrogen Production Hydrogen Delivery Hydrogen Storage Fuel Cells Safety, Codes and Standards Education Market Transformation Manufacturing Systems Integration Systems Analysis Energy Storage Basic Research Vision and Roadmaps Hydrogen Production Biological Hydrogen Production Workshop, September 24-25, 2013. Hydrogen Separations and Purification Working Group Meeting, November 7, 2007. Bio-Derived Liquids to Hydrogen Distributed Reforming Working Group Meeting, November 6, 2007. The DOE Workshop on Hydrogen Production via Direct Fermentation, June 9, 2004. Electrolysis-Utility Integration Workshop Proceedings, September 22-23, 2004.

371

2014 DOE Annual Occupational Medicine Workshop and Webinar (OMWW) |  

Broader source: Energy.gov (indexed) [DOE]

2014 DOE Annual Occupational Medicine Workshop and Webinar (OMWW) 2014 DOE Annual Occupational Medicine Workshop and Webinar (OMWW) 2014 DOE Annual Occupational Medicine Workshop and Webinar (OMWW) March 17-18, 2014 DOE Annual Occupational Medicine Workshop and Webinar (OMWW): Registration, Directions, Lodging, and Access REGISTRATION AND CONFERENCE SYSTEM The 2014 DOE Occupational Medicine Workshop and Webinar will be held March 17-18 in Room 4A-104 of the DOE Forrestal Building in Washington, DC. Register for the 2014 OMWW at http://hsspublic.energy.gov/Workshops/CMO/2014/Registration.aspx. The deadline for registration will be January 17, 2014 in order to comply with conference system requirements. Upon completing the registration, you will immediately receive a confirmatory email. An additional confirmatory email will be sent to registrants shortly after January 17th (once all

372

2nd Workshop on Process-based approaches for Model-Driven Engineering (submission) This work was partially supported by the PCSI program Zero Defect Systems (http://www.auf.org/anglais)  

E-Print Network [OSTI]

2nd Workshop on Process-based approaches for Model-Driven Engineering (submission) This work and traditional verification by simulation is no more practical. Moreover, the increase in integration density would like to emphasize is that refinement (from an abstract model to the point where the system

Boyer, Edmond

373

Lger A., Duval C., Weber P., Levrat E., Farret R. "BAYESIAN NETWORK MODELLING THE RISK ANALYSIS OF COMPLEX SOCIO TECHNICAL SYSTEMS". Submitted to: 4th Workshop on Advanced Control and Diagnosis, Nancy -France, 16 et 17 nov., 2006.  

E-Print Network [OSTI]

, Probabilistic risk assessment. 1. INTRODUCTION In classified installations1 (nuclear power plants, chemical OF COMPLEX SOCIO TECHNICAL SYSTEMS". Submitted to: 4th Workshop on Advanced Control and Diagnosis, Nancy - France, 16 et 17 nov., 2006. BAYESIAN NETWORK MODELLING THE RISK ANALYSIS OF COMPLEX SOCIO TECHNICAL

Boyer, Edmond

374

2005 IEEE Workshop on Applications of Signal Processing to Audio and Acoustics October 16-19, 2005, New Paltz, NY A PROTOTYPE SYSTEM FOR OBJECT CODING OF MUSICAL AUDIO  

E-Print Network [OSTI]

2005 IEEE Workshop on Applications of Signal Processing to Audio and Acoustics October 16-19, 2005, New Paltz, NY A PROTOTYPE SYSTEM FOR OBJECT CODING OF MUSICAL AUDIO Emmanuel Vincent and Mark D coding of musical audio, and more precisely with the extraction of pitched sound objects in polyphonic

Paris-Sud XI, Université de

375

Risk Management Techniques and Practice Workshop Workshop Report  

SciTech Connect (OSTI)

At the request of the Department of Energy (DOE) Office of Science (SC), Lawrence Livermore National Laboratory (LLNL) hosted a two-day Risk Management Techniques and Practice (RMTAP) workshop held September 18-19 at the Hotel Nikko in San Francisco. The purpose of the workshop, which was sponsored by the SC/Advanced Scientific Computing Research (ASCR) program and the National Nuclear Security Administration (NNSA)/Advanced Simulation and Computing (ASC) program, was to assess current and emerging techniques, practices, and lessons learned for effectively identifying, understanding, managing, and mitigating the risks associated with acquiring leading-edge computing systems at high-performance computing centers (HPCCs). Representatives from fifteen high-performance computing (HPC) organizations, four HPC vendor partners, and three government agencies attended the workshop. The overall workshop findings were: (1) Standard risk management techniques and tools are in the aggregate applicable to projects at HPCCs and are commonly employed by the HPC community; (2) HPC projects have characteristics that necessitate a tailoring of the standard risk management practices; (3) All HPCC acquisition projects can benefit by employing risk management, but the specific choice of risk management processes and tools is less important to the success of the project; (4) The special relationship between the HPCCs and HPC vendors must be reflected in the risk management strategy; (5) Best practices findings include developing a prioritized risk register with special attention to the top risks, establishing a practice of regular meetings and status updates with the platform partner, supporting regular and open reviews that engage the interests and expertise of a wide range of staff and stakeholders, and documenting and sharing the acquisition/build/deployment experience; and (6) Top risk categories include system scaling issues, request for proposal/contract and acceptance testing, and vendor technical or business problems. HPC, by its very nature, is an exercise in multi-level risk management. Every aspect of stewarding HPCCs into the petascale era, from identification of the program drivers to the details of procurement actions and simulation environment component deployments, represents unprecedented challenges and requires effective risk management. The fundamental purpose of this workshop was to go beyond risk management processes as such and learn how to weave effective risk management practices, techniques, and methods into all aspects of migrating HPCCs into the next generation of leadership computing systems. This workshop was a follow-on to the Petascale System Integration Workshop hosted by Lawrence Berkeley National Laboratory (LBNL)/NERSC last year. It was intended to leverage and extend the risk management experience of the participants by looking for common best practices and unique processes that have been especially successful. This workshop assessed the effectiveness of tools and techniques that are or could be helpful in HPCC risk management, with a special emphasis on how practice meets process. As the saying goes: 'In theory, there is no difference between theory and practice. In practice there is'. Finally, the workshop brought together a network of experts who shared information as technology moves into the petascale era and beyond.

Quinn, T; Zosel, M

2008-12-02T23:59:59.000Z

376

DOE/EIS-0285; Bonneville Power Administration Transmission System Vegetation Management Program Final Environmental Impact Statement (May 2000)  

Broader source: Energy.gov (indexed) [DOE]

Statement - Appendices Statement - Appendices DOE/EIS-0285 Arrow-leaf Balsamroot Cooperating Agencies Bonneville Power Administration Transmission System Vegetation Management Program Final Environmental Impact Statement DOE/EIS-0285 APPENDICES May 2000 Table of Contents Appendix A - Public Involvement: Publications Appendix B - Biological Weed Control Agents Appendix C - Bonneville Pesticide Applicator Certification Plan Appendix D - Sample Educational Information Appendix E - Clearance Criteria Appendix F - FS Mitigation Measures and Background Appendix G - BLM Mitigation Measures and Background Appendix H - Herbicide Fact Sheets 2,4-D Azafenidin Bromacil Chlorsulfuron Clopyralid Dicamba Dichlobenil Diuron Fosamine Ammonium Glyphosate Halosulfuron-methyl Hexazinone Imazapyr Isoxaben Mefluidide Metsulfuron-methyl

377

Studying Fischer-Tropsch catalysts using transmission electron microscopy and model systems of nanoparticles on planar supports.  

SciTech Connect (OSTI)

Nanoparticle model systems on planar supports form a versatile platform for studying morphological and compositional changes of catalysts due to exposure to realistic reaction conditions. We review examples from our work on iron and cobalt catalysts, which can undergo significant rearrangement in the reactive environment of the Fischer-Tropsch synthesis. The use of specially designed, silicon based supports with thin film SiO{sub 2} enables the application of transmission electron microscopy, which has furnished important insight into e.g. the mechanisms of catalyst regeneration.

Thune, P. C.; Weststrate, C. J.; Moodley, P.; Saib, A. M.; van de Loosdrecht, J.; Miller, J. T.; Niemantsverdriet, J. W. (Chemical Sciences and Engineering Division); (Eindhoven Univ. of Technology); (Sasol Technology)

2011-01-01T23:59:59.000Z

378

Issues arising with the application of optical fiber transmission in class 1E systems in nuclear power plants  

SciTech Connect (OSTI)

The application of fiber optic links and networks in safety-critical systems in the next generation of nuclear power plants, as well as in some digital upgrades in present-day plants, will mean that these links must be highly reliable and able to withstand the effect of environmental stressors present at the installation location. This paper discusses the failure modes and age-related mechanisms of fiber optic transmission components and identifies environmental stressors that could adversely affect their reliability over the long term. Some of the standards that could be used in their qualification for safety-critical applications are also discussed briefly.

Korsah, K. [Oak Ridge National Lab., TN (United States); Antonescu, C. [Nuclear Regulatory Commission, Washington, DC (United States). Office of Nuclear Regulatory Research

1993-12-31T23:59:59.000Z

379

RAPID/BulkTransmission/About | Open Energy Information  

Open Energy Info (EERE)

Contribute Contact Us About Bulk Transmission Lattice.jpg High-voltage transmission lines form the backbone of electricity systems. Transmission lines are designed to carry...

380

Overhead electric power transmission line jumpering system for bundles of five or more subconductors  

DOE Patents [OSTI]

Jumpering of electric power transmission lines at a dead end tower. Two transmission line conductor bundles each contain five or more spaced apart subconductors (5) arranged in the shape of a cylinder having a circular cross section. The ends of each bundle of subconductors are attached with insulators to a dead end tower (1). Jumpering allows the electric current to flow between the two bundles of subconductors using jumper buses, internal jumper conductors, and external jumper conductors. One or more current collecting jumper buses (37) are located inside each bundle of subconductors with each jumper bus being attached to the end of a subconductor. Small-diameter internal jumper conductors (33) are located in the inherently electrically shielded area inside each bundle of subconductors with each subconductor (except ones having an attached jumper bus) having one internal jumper conductor connected between that subconductor's end and a jumper bus. Large-diameter external jumper conductors (9) are located outside each bundle of subconductors with one or more external jumper conductors being connected between the jumper buses in one bundle of subconductors and the jumper buses in the other bundle.

Winkelman, Paul F. (Beaverton, OR)

1982-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

DOE/EIS-0285/SA-134: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (Bandon-Rogue-GoldBeach)(3/24/03)  

Broader source: Energy.gov (indexed) [DOE]

4, 2003 4, 2003 REPLY TO ATTN OF: KEP/4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-134-Bandon-Rogue-GoldBeach) Ben Tilley Natural Resource Specialist - TFE/Alvey Proposed Action: Vegetation Management for the Bandon-Rogue-Gold Beach transmission line corridor. This corridor includes the Bandon-Rogue #1 115 kV transmission line from Bandon Substation to Rogue Substation and the Rogue-Gold Beach #1 and #2 115kV transmission lines, starting at Rogue Substation and ending at Gold Beach Substation. In addition the project includes adjacent portions of the Fairview-Rogue #1 230 kV Transmission Line. Location: The project is located in the BPA Eugene Region, Coos and Curry Counties, Oregon.

382

Tandem mirror theory workshop  

SciTech Connect (OSTI)

The workshop was divided into three sections which were constituted according to subject matter: RF Heating, MHD Equilibrium and Stability, and Transport and Microstability. An overview from Livermore's point of view was given at the beginning of each session. Each session was assigned a secretary to take notes. These notes have been used in preparing this report on the workshop. The report includes the activities, conclusions, and recommendations of the workshop.

None

1981-05-01T23:59:59.000Z

383

Kyoto Workshop  

Broader source: Energy.gov (indexed) [DOE]

of Arkansas 15 15 UA Proposed Solution Multiport converter topology uses common transformer, reducing part count for total system. High frequency transformer link results...

384

Teacher Resource Center: Customized Workshops  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Customized Workshops Customized Workshops TRC Home TRC Fact Sheet Library Curricular Resources Science Fair Resources Bibliographies sciencelines The Best of sciencelines Archives Annotated List of URLs Catalog Teacher's Lounge Full Workshop Catalog Customized Workshops Scheduled Workshops Special Opportunities Teacher Networks Science Lab Fermilab Science Materials Samplers Order Form Science Safety Issues Tech Room Fermilab Web Resources From time to time we receive requests for information about workshops offered through the Fermilab Teacher Resource Center. We have conducted workshops for schools, districts and intermediate service agencies. We work closely with organizers to customize the workshops to their needs—the discussion and collaboration is essential. We receive many requests for

385

QCD Evolution Workshop: Introduction  

SciTech Connect (OSTI)

The introduction talk given at the beginning of QCD Evolution workshop held in Thomas Jefferson National Accelerator Facility (Jefferson Lab) on May 14 -17, 2012.

Alexey Prokudin

2012-12-01T23:59:59.000Z

386

UESC Workshop Materials  

Broader source: Energy.gov [DOE]

Presentation covers the UESC Workshop Materials and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

387

GBTL Workshop Attendees  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Natural Gas-Biomass to Liquids Workshop Attendees Technical Barriers Breakout Track Julio Baez, Lawrence Berkeley National Laboratory Robert Baldwin, National Renewable Energy...

388

STXM Workshop: 2007  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Papers Location Registration Visitor Information Transportation Tourism & Dining Workshop on STXM and X-ray Nanoprobe Capabilities and Needs for Geo-, Environmental, and Biological...

389

GBTL Workshop GHG Emissions  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Advisory Committees Science & Innovation Clean Coal Carbon Capture and Storage Oil & Gas 9 | Natural Gas-Biomass to Liquids Workshop DOE FE Studies Add National Perspective...

390

EV Everywhere Workshop  

Broader source: Energy.gov (indexed) [DOE]

Workshop David Sandalow Under Secretary of Energy (Acting) Assistant Secretary for Policy and International Affairs U.S. Department of Energy Chicago, Illinois July 26...

391

Conferences, workshops, trainings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Conferences aboutassetsimagesicon-70th2.jpg Conferences, workshops, trainings Los Alamos National Lab is situated on a mesatop on the eastern side of the Jemez Mountains, an...

392

Multimaterial Joining Workshop  

Broader source: Energy.gov [DOE]

Agenda for the Multimaterial Joining Workshop held on July 23, 2012 to identify opportunities, challenges, barriers, and actions needed to advance use of multimaterial joining technologies

393

SunShot Initiative: Transmission Grid Integration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission Grid Integration to Transmission Grid Integration to someone by E-mail Share SunShot Initiative: Transmission Grid Integration on Facebook Tweet about SunShot Initiative: Transmission Grid Integration on Twitter Bookmark SunShot Initiative: Transmission Grid Integration on Google Bookmark SunShot Initiative: Transmission Grid Integration on Delicious Rank SunShot Initiative: Transmission Grid Integration on Digg Find More places to share SunShot Initiative: Transmission Grid Integration on AddThis.com... Concentrating Solar Power Photovoltaics Systems Integration Research, Development, & Demonstration Distribution Grid Integration Transmission Grid Integration Solar Resource Assessment Technology Validation Power Electronics & Balance of System Hardware Technologies Competitive Awards

394

Abstract --The need to determine adequate regulations in the transmission activity in deregulated environments does not  

E-Print Network [OSTI]

be followed. Index Terms--Transmission expansion, Transmission planning, Transmission systems, Transmission pricing, Open access. I INTRODUCTION he presence of economies of scale and the specificity

Dixon, Juan

395

Transmission Access Resources  

Broader source: Energy.gov [DOE]

Historically, the addition of new electric generation facilities has been accompanied by new transmission systems. For example, large nuclear and coal plants built in the 1960s and 1970s required...

396

Exploration of Resource and Transmission Expansion Decisions in the Western Renewable Energy Zone Initiative  

E-Print Network [OSTI]

nearest transmission system substation, and are derived fromthe nearest transmission substation, the capacity factor of

Mills, Andrew D

2011-01-01T23:59:59.000Z

397

EM Hosts Used Fuel Management Workshop | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Hosts Used Fuel Management Workshop Hosts Used Fuel Management Workshop EM Hosts Used Fuel Management Workshop September 30, 2013 - 12:00pm Addthis Participants in EM’s Office of Nuclear Materials Disposition workshop with Swedish executives gather for a photo. Participants in EM's Office of Nuclear Materials Disposition workshop with Swedish executives gather for a photo. WASHINGTON, D.C. - EM's Office of Nuclear Materials Disposition held a workshop with Swedish executives earlier this month to learn about their approaches to designing a national waste management program. EM officials met with representatives from SKB International, the consulting arm of SKB, the Swedish nuclear fuel and waste management company. They examined SKB's integrated waste management system, known as KBS-3, and the potential for efficiencies and lifecycle costs reductions

398

Natural Phenomena Hazards (NPH) Workshop | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Natural Phenomena Hazards (NPH) Workshop Natural Phenomena Hazards (NPH) Workshop Natural Phenomena Hazards (NPH) Workshop The Energy Department Natural Phenomena Hazards (NPH) Workshop, sponsored by the Chief of Nuclear Safety and the Chief of Defense Nuclear Safety, was held October 25-26, 2011, in Germantown, Maryland. The workshop brought together approximately 80 experts involved in the characterization of, and mitigation against, natural hazards that can impact nuclear facilities. The workshop featured twenty presentations as well as a breakout session devoted to discussing the status of the commonly used structural analysis code SASSI, a System for Analysis of Soil-Structure Interaction. A Method for Evaluating Fire after Earthquake Scenarios for Single Buildings_1.pdf Addressing Uncertainties in Design Inputs - A Case Study of Probabilistic

399

EM Hosts Used Fuel Management Workshop | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

EM Hosts Used Fuel Management Workshop EM Hosts Used Fuel Management Workshop EM Hosts Used Fuel Management Workshop September 30, 2013 - 12:00pm Addthis Participants in EM’s Office of Nuclear Materials Disposition workshop with Swedish executives gather for a photo. Participants in EM's Office of Nuclear Materials Disposition workshop with Swedish executives gather for a photo. WASHINGTON, D.C. - EM's Office of Nuclear Materials Disposition held a workshop with Swedish executives earlier this month to learn about their approaches to designing a national waste management program. EM officials met with representatives from SKB International, the consulting arm of SKB, the Swedish nuclear fuel and waste management company. They examined SKB's integrated waste management system, known as KBS-3, and the potential for efficiencies and lifecycle costs reductions

400

Natural Phenomena Hazards (NPH) Workshop | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Natural Phenomena Hazards (NPH) Workshop Natural Phenomena Hazards (NPH) Workshop Natural Phenomena Hazards (NPH) Workshop The Energy Department Natural Phenomena Hazards (NPH) Workshop, sponsored by the Chief of Nuclear Safety and the Chief of Defense Nuclear Safety, was held October 25-26, 2011, in Germantown, Maryland. The workshop brought together approximately 80 experts involved in the characterization of, and mitigation against, natural hazards that can impact nuclear facilities. The workshop featured twenty presentations as well as a breakout session devoted to discussing the status of the commonly used structural analysis code SASSI, a System for Analysis of Soil-Structure Interaction. A Method for Evaluating Fire after Earthquake Scenarios for Single Buildings_1.pdf Addressing Uncertainties in Design Inputs - A Case Study of Probabilistic

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

(DOE/EIS-0285/SA-14): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 6/6/01  

Broader source: Energy.gov (indexed) [DOE]

4) 4) Bill Erickson - TFP/ Walla Walla Region Natural Resource Specialist Proposed Action: Vegetation Management at the Teakean Butte Microwave site. Location: Clearwater County, ID, Walla Walla Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to remove 28 danger trees and dense brush from the microwave site in order to provide a 75 -80 foot safety buffer for fire control and Microwave Beam path. The work will protect BPA's investment at the site and provide system reliability. All work will be in accordance with the National Electrical Safety Code and BPA standards. Analysis: This project meets the standards and guidelines for the Transmission System Vegetation Management Program Final Environmental Impact Statement (FEIS) and Record of Decision

402

2011 Alkaline Membrane Fuel Cell Workshop Final Report  

SciTech Connect (OSTI)

A workshop addressing the current state-of-the-art in alkaline membrane fuel cells (AMFCs) was held May 8-9, 2011, at the Crystal Gateway Marriott in Arlington, Virginia. This workshop was the second of its kind, with the first being held December 11-13, 2006, in Phoenix, Arizona. The 2011 workshop and associated workshop report were created to assess the current state of AMFC technology (taking into account recent advances), investigate the performance potential of AMFC systems across all possible power ranges and applications, and identify the key research needs for commercial competitiveness in a variety of areas.

Pivovar, B.

2012-02-01T23:59:59.000Z

403

DOE Transmission Capacity Report | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Transmission Capacity Report Transmission Capacity Report DOE Transmission Capacity Report DOE Transmission Capacity Report: Transmission lines, substations, circuit breakers, capacitors, and other equipment provide more than just a highway to deliver energy and power from generating units to distribution systems. Transmission systems both complement and substitute for generation. Transmission generally enhances reliability; lowers the cost of electricity delivered to consumers; limits the ability of generators to exercise market power; and provides flexibility to protect against uncertainties about future fuel prices, load growth, generator construction, and other factors affecting the electric system. DOE Transmission Capacity Report More Documents & Publications Report to Congress:Impacts of the Federal Energy Regulatory Commission's

404

NEET WORKSHOP REPORT  

Broader source: Energy.gov (indexed) [DOE]

NEET WORKSHOP REPORT Table of Contents Acronyms and Initialisms ................................................................................................... iii 1. Introduction .................................................................................................................... 1 1.1 Key Challenges Facing Nuclear Energy ........................................................................... 1 1.2 DOE Nuclear R&D Objectives ......................................................................................... 2 1.3 NEET Program Workshop Objectives .............................................................................. 3 2. Discussion of Crosscutting Technologies ...................................................................... 5

405

Proceedings IEA Workshop Legionella  

E-Print Network [OSTI]

be not less than 60°C. 95% of thermal Solar panels sys- tems are both for hot water and for water heating of the workshop is to investigate the risk of bacterial growth in solar water heaters and the risk of Legionnaire's disease for future growth of the solar water heaters market. The workshop was divided in three parts

406

QTR Cornerstone Workshop  

Broader source: Energy.gov [DOE]

Tthe Office of the Under Secretary for Science and Energy is hosting a workshop to gain input from leaders in academia, industry, and government. At the workshop, we will explore technology opportunities across the energy spectrumranging from power generation to advanced fuels to next generation manufacturing.

407

Past Meetings and Workshops  

Broader source: Energy.gov [DOE]

Industry workshops help the U.S. Department of Energy (DOE) Solar Energy Technologies Office obtain a wide range of stakeholder feedback to guide the SunShot Initiative. DOE held the workshops below to identify barriers and opportunities associated with the SunShot goals.

408

Critical Materials Workshop  

Broader source: Energy.gov [DOE]

AMO hosted a public workshop on Tuesday, April 3, 2012 in Arlington, VA to provide background information on critical materials assessment, the current research within DOE related to critical materials, and the foundational aspects of Energy Innovation Hubs. Additionally, the workshop solicited input from the critical materials community on R&D gaps that could be addressed by DOE.

409

2012 Congestion Study Workshops to be Held in December; Agendas Now  

Broader source: Energy.gov (indexed) [DOE]

Congestion Study Workshops to be Held in December; Agendas Now Congestion Study Workshops to be Held in December; Agendas Now Available 2012 Congestion Study Workshops to be Held in December; Agendas Now Available November 27, 2011 - 9:34am Addthis The Department is initiating preparations for development of the 2012 National Electric Transmission Congestion Study. The Department is seeking comments on what publicly-available data and analysis should be used to identify and understand the significance and character of transmission congestion. DOE will host four regional pre-study workshops to receive input and suggestions concerning the study: - December 6 in Philadelphia, PA - December 8 in St. Louis, MO - December 13 in Portland, OR - December 15 in San Diego, CA. Agendas for the workshops are available for download. Online registration

410

DOE_UTSR_Workshop'10.pdf  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

& Structures Laboratory & Structures Laboratory - Power Systems and Propulsion Materials Group - UTSR - Annual Workshop 10/20/10 1 Chemical Engineering and Materials Science! Advanced Power and Energy Program (APEP)! University of California, Irvine! Tel: (949) 824-3858; Fax: (949) 824-2541! mumm@uci.edu! 2010 University Turbine Systems Research Workshop! Nittany Lion Inn, University Park, PA; October 19 th - 21 st ! Daniel R. Mumm! U.S. Department of Energy; National Energy Technology Laboratory! Agreement # DE-FE0004727; Project Manager: Dr. Patcharin Burke! Advanced Materials & Structures Laboratory - Power Systems and Propulsion Materials Group - UTSR - Annual Workshop 10/20/10 2  Derive a mechanisms-based understanding of TGO layer and TBC system degradation associated with turbine operation with syngas and HHC fuels!

411

Distribution Workshop  

Broader source: Energy.gov (indexed) [DOE]

SHERATON CRYSTAL CITY SEPTEMBER 24-26, 2012 Grid Tech Team U.S. Department of Energy DOE Grid Tech Team (GTT)  The Grid Tech Team (GTT), established by the Office of the Undersecretary of Energy, was tasked with coordinating grid-related activities across the Department and accelerating modernization of the electric power system.  Currently, the GTT comprise of representatives from OE, EERE, ARPA-E, Fossil Energy, Science, Policy and International Affairs, CFO, and the Office of the Secretary of Energy. Vision of the Future Grid A seamless, cost-effective electricity system, from generation to end- use, capable of meeting all clean energy demands and capacity requirements, while allowing consumer participation and electricity use as desired:

412

Ground Motion Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2nd Advanced ICFA Beam Dynamics Workshop 2nd Advanced ICFA Beam Dynamics Workshop on Ground Motion in Future Accelerators November 6 - 9, 2000 SLAC Coordinators: Andrei Seryi & Tor Raubenheimer Proceedings Updated June 26, 2001 Agenda and Presentations Workshop photos Summaries Useful links Poster Goals Introduction to the problems Structure Registration Registered participants Committees Location, Accommodations and Travel Workshop on Ground Motion in Future Accelerators A workshop was held at SLAC that was devoted to ground motion and its effects on future accelerators. Ground motion and vibration can be a limiting effect in synchrotron light sources, hadron circular colliders, and electron/positron linear colliders. Over the last several years, there has been significant progress in the understanding of the ground motion and its effects, however, there are

413

Workshop Report: Health Physics Journal  

Broader source: Energy.gov [DOE]

Workshop Report on Atomic Bomb Dosimetry Residual Radiation Exposure: Recent Research and Suggestions for Future Studies.

414

K.K. Gan ATLAS Tracker Upgrade Workshop 1 Progress Report on Joint ATLAS/CMS  

E-Print Network [OSTI]

K.K. Gan ATLAS Tracker Upgrade Workshop 1 Progress Report on Joint ATLAS/CMS SLHC Opto ATLAS Tracker Upgrade Workshop 2 Outline Introduction Subgroups activities Summary #12;K.K. Gan ATLAS System #12;K.K. Gan ATLAS Tracker Upgrade Workshop 4 Group A: Lesson Learned and to be Learned from LHC

Gan, K. K.

415

LCCC Workshop -Lund Sweden -December 7, 2011 EfficientlyAttentive Quantized  

E-Print Network [OSTI]

LCCC Workshop - Lund Sweden - December 7, 2011 EfficientlyAttentive Quantized Event Notre Dame, IN, USA #12;LCCC Workshop - Lund Sweden - December 7, 2011 Sampled Data Control System(t) = ^xk for t [sk, sk+1). Minimum Information for Stabilization? #12;LCCC Workshop - Lund Sweden

Lemmon, Michael

416

OREM Hosts Community Workshop | Department of Energy  

Energy Savers [EERE]

OREM Hosts Community Workshop OREM Hosts Community Workshop The Oak Ridge Office of Environmental Management (OREM) hosted a community workshop on June 24. The purpose of the...

417

2014 Program Management Workshop Speaker Biographies | Department...  

Office of Environmental Management (EM)

4 Program Management Workshop Speaker Biographies 2014 Program Management Workshop Speaker Biographies 2014 PM Workshop Speaker Biographies24 Mar 2014.pdf More Documents &...

418

Integrated Safety Management Champions Workshop | Department...  

Broader source: Energy.gov (indexed) [DOE]

Champions Workshop Integrated Safety Management Champions Workshop Integrated Safety Management Champions Workshop Dear colleagues, On behalf of Mr. Glenn Podonsky, Chief Health,...

419

Advanced Magnetic Resonance Workshop Report | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Magnetic Resonance Workshop Report Advanced Magnetic Resonance Workshop Report NMR and EPR Workshop: Mueller KT, Washton NM, Pruski M, Lipton AS. 2013. "Science Drivers and...

420

mhd-workshop | netl.doe.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Conference Proceedings Magnetohydrodynamic Power Generation Workshop Wednesday, October 1 - 2, 2014 Workshop Agenda Session 1: Introduction Workshop Welcome Susan Maley; Technology...

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Reversible Fuel Cells Workshop | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Reversible Fuel Cells Workshop Reversible Fuel Cells Workshop The National Renewable Energy Laboratory hosted a workshop addressing the current state-of-the-art of reversible fuel...

422

Bonneville Power Administration Transmission System Vegetation Management Program - Final Environmental Impact Statement  

SciTech Connect (OSTI)

Bonneville is responsible for maintaining a network of 24,000 kilometers (km) or 15,000 miles (mi.) of electric transmission lines and 350 substations in a region of diverse vegetation. This vegetation can interfere with electric power flow, pose safety problems for us and the public, and interfere with our ability to maintain these facilities. We need to (1) keep vegetation away from our electric facilities; (2) increase our program efficiency and consistency; (3) review herbicide use (under increased public scrutiny); and (4) maximize the range of tools we can use while minimizing environmental impact (Integrated Vegetation Management). This Final Environmental Impact Statement (FEIS) establishes Planning Steps for managing vegetation for specific projects (to be tiered to this Environmental Impact Statement (EIS)). In addition to No Action (current practice), alternatives are presented for Rights-of-way, Electric Yards, and Non-electric Facilities (landscaping, work yards). Four vegetation control methods are analyzed manual, mechanical, herbicide, and biological. Also evaluated are 23 herbicide active ingredients and 4 herbicide application techniques (spot, localized, broadcast, and aerial). For rights-of-way, we consider three sets of alternatives: alternative management approaches (time-driven or establishing low-growing plant communities); alternative method packages; and, if herbicides are in a methods package, alternative vegetation selections (noxious weeds, deciduous, or any vegetation). For electric yards, one herbicide-use alternative is considered. For non-electric facilities, two method package alternatives are considered. For rights-of-way, the environmentally preferred alternative(s) would use manual, mechanical, and biological control methods, as well as spot and localized herbicide applications for noxious and deciduous plant species; the BPA-preferred alternative(s) would add broadcast and aerial herbicide applications, and would use herbicides on any vegetation. Both would favor a management approach that fosters low-growing plant communities.

N /A

2000-06-23T23:59:59.000Z

423

DAMAGE DETECTION STRATEGIES IN STRUCTURAL HEALTH MONITORING OF OVERHEAD POWER TRANSMISSION SYSTEM  

E-Print Network [OSTI]

part of T&D System that goes from the power plant to substations near demand points. "Distribution" refers to the low voltage part of T&D System that connects substations and consumers' switchgear boxes of 245 HV lines that gives a total of 13 053 km of HV lines distributed on the area of 312 679 km2

Boyer, Edmond

424

Cross-layer packet prioritization for error-resilient transmission of IPTV system over wireless network  

Science Journals Connector (OSTI)

This paper proposes a novel cross-layer packet prioritization scheme that overcomes the limitations of conventional video prioritization schemes for IPTV system. In the conventional schemes, the Extend profile or frame unit is used for prioritization ... Keywords: IPTV system, error-resilient video streaming, per-packet prioritization algorithm

Kyungmin Go; Sungwon Kang; Yohaan Yoon; Myungchul Kim; Ben Lee

2014-03-01T23:59:59.000Z

425

Aerospace Power & Electronics Simulation Workshop 2004 Satellite Attitude Control  

E-Print Network [OSTI]

Aerospace Power & Electronics Simulation Workshop 2004 · Satellite Attitude Control System Design Using Reaction Wheels Bhanu Gouda Brian Fast Dan Simon #12;2Aerospace Power & Electronics Simulation;3Aerospace Power & Electronics Simulation Workshop 2004 ADCS ·ADCS: Attitude Determination and Control

Simon, Dan

426

SunShot Presentation PV Module Reliabity Workshop Opening Session  

Broader source: Energy.gov [DOE]

This PowerPoint slide deck was originally presented at the opening session of the 2013 NREL PV Module Reliability Workshop on Feb. 26-27, 2013 in Golden, CO. It provides an overview of the DOE SunShot initiative, discusses systems integration and technology validation activities, and highlighted the goals and key agenda items for the workshop.

427

An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.  

SciTech Connect (OSTI)

References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

Litzenberger, Wayne; Lava, Val

1994-08-01T23:59:59.000Z

428

Microsoft Word - ieRoadmap Workshop_FINAL.doc  

Broader source: Energy.gov (indexed) [DOE]

First-ever ieRoadmap Workshop Reviews Progress in Achieving Roadmap Goals First-ever ieRoadmap Workshop Reviews Progress in Achieving Roadmap Goals On May 28-29, 2008, the first ieRoadmap Workshop was held to assist the energy sector in assessing alignment of current industry projects with the goals outlined in the Roadmap to Secure Control Systems in the Energy Sector. Held in Chicago, Illinois, the workshop was sponsored by the Energy Sector Control Systems Working Group (ESCSWG), made up of private sector and government leaders working to facilitate and guide the implementation of the Roadmap Approximately 50 participants, including asset owners, project leaders, vendors, researchers, and program managers, attended the two-day workshop. Project leads from 25 industry projects focusing on securing energy control systems presented their research

429

U.S. Department of Energy Schedules Regional Workshops to Provide Expert  

Broader source: Energy.gov (indexed) [DOE]

Schedules Regional Workshops to Provide Schedules Regional Workshops to Provide Expert Input on 2009 Transmission Congestion Study U.S. Department of Energy Schedules Regional Workshops to Provide Expert Input on 2009 Transmission Congestion Study May 16, 2008 - 12:00pm Addthis Second Congestion Study to Further Evaluate our Nation's Electricity Reliability in the Face of Growing Energy Demand WASHINGTON, DC - As part of the Bush Administration's comprehensive effort to provide wide-ranging data and thorough statistical analysis in its 2009 National Transmission Congestion Study (Congestion Study), U.S. Department of Energy (DOE) Assistant Secretary for Electricity Delivery and Energy Reliability (OE) Kevin Kolevar today announced that the Department will hold six regional technical workshops across the country, to seek input on

430

U.S. Department of Energy Schedules Regional Workshops to Provide Expert  

Broader source: Energy.gov (indexed) [DOE]

U.S. Department of Energy Schedules Regional Workshops to Provide U.S. Department of Energy Schedules Regional Workshops to Provide Expert Input on 2009 Transmission Congestion Study U.S. Department of Energy Schedules Regional Workshops to Provide Expert Input on 2009 Transmission Congestion Study May 16, 2008 - 1:53pm Addthis Second Congestion Study to Further Evaluate our Nation's Electricity Reliability in the Face of Growing Energy Demand WASHINGTON, DC - As part of the Bush Administration's comprehensive effort to provide wide-ranging data and thorough statistical analysis in its 2009 National Transmission Congestion Study (Congestion Study), U.S. Department of Energy (DOE) Assistant Secretary for Electricity Delivery and Energy Reliability (OE) Kevin Kolevar today announced that the Department will hold six regional technical workshops across the country, to seek input on

431

EIS(DOE/EIS-0285/SA-61) Supplement Analysis for the Transmission System Vegetation Management Program FEIS 4/15/02  

Broader source: Energy.gov (indexed) [DOE]

April 15, 2002 April 15, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-61 Tom Murphy - TFS/Bell-1 - Natural Resource Specialist Proposed Action: Vegetation Management along the Bell-Boundary No.3, 84/4 to 96/1 Transmission Line ROW. The line is a 230kV Double Circuit Transmission Line having an easement width of 100 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor. Location: The ROW is located in both Stevens and Pend Oreille County, WA, being in the Spokane Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of-

432

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-151-Big Eddy-Ostrander 1  

Broader source: Energy.gov (indexed) [DOE]

8, 2003 8, 2003 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-151-Big Eddy-Ostrander 1 Ed Tompkins Natural Resource Specialist-TFO/LMT Proposed Action: Removal of danger trees along the Big Eddy-Ostrander-1 transmission line corridor. This corridor also includes segments of the Big Eddy-Troutdale, Ostrander-Troutdale, Big Eddy-McLoughlin and Bid Eddy-Chemawa transmission lines. Referencing the Big-Eddy- Ostrander-1 transmission line, the project extends from tower 39/3 to 72/2. The portion of the ROW extending from 39/3 west to 44/5+313 falls within the Zigzag Ranger District of the Mt. Hood National Forest, Clackamas County, Oregon. All work conducted

433

(DOE/EIS-0285/SA 84): Supplement Analysis for the Transmission System Vegetation Management Program FEIS Monroe-Custer No.1 7/1/02  

Broader source: Energy.gov (indexed) [DOE]

July July 1, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA 84 Monroe-Custer No.l Don Atkinson -- - TFN/Snohomish Proposed Action: Vegetation Management along the Monroe-Custer No. 1500kV transmission line from structure 61/1 through structure 88/4. This project includes contemporaneous vegetation management along the Monroe-Custer No. 2 500kV and the Arlington-Bellingham 230kV transmission line corridors which run parallel to the subject transmission line. Corridor width varies from 140 to 825 feet. (All structure locations referenced in this SA refer to the Monroe-Custer No. 1.) The project area is located within Whatcom County, Washington. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the

434

(DOE/EIS-0285/SA-06): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 4/13/01  

Broader source: Energy.gov (indexed) [DOE]

4/13/01 4/13/01 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-06) Bill Erickson - TFP/Walla Walla Natural Resource Specialist Proposed Action: Vegetation Management of annual weeds on seven acres of Bonneville Power Administration (BPA) owned pastureland at the Walla Walla Substation. Location: The pastureland is adjacent to the Walla Walla Substation and is located east and north of the fenced substation, all within the BPA property boundary. Proposed by: Bonneville Power Administration. Description of the Proposed Action: BPA proposes to apply selected herbicides to control annual weeds that are competing with native grasses that were seeded two years ago. Herbicides will also

435

(DOE/EIS-0285/SA-81): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 7/9/02  

Broader source: Energy.gov (indexed) [DOE]

July 9,2002 July 9,2002 REPLY TO ATTN OF: KEPR-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-81) Randy Melzer Redmond Deputy Regional Manager - TFR/REDMOND Proposed Action: Vegetation Management for fifteen Substations in The Dalles District. (See list of facilities under planning step 1). Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes total vegetation management (bare ground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within The Dalles District of the Redmond Region. Analysis: The attached checklist shows the resources that were found during this analysis and what

436

(DOE/EIS-0285/SA-74): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 7/1/02  

Broader source: Energy.gov (indexed) [DOE]

2002 2002 REPLY TO ATTN OF: KEPR-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-74) Randy Melzer Redmond Deputy Regional Manager - TFR/REDMOND Proposed Action: Vegetation Management for five Substations in the Malin District. (See list of facilities under planning step 1). Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes total vegetation management (bare ground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Malin District of the Redmond Region. Analysis: The attached checklist shows the resources that were found during this analysis and what mitigation measures are required to protect those resources. In addition,

437

(DOE/EIS-0285/SA-82): Supplemental Analysis for Transmission System Vegetation Management Program FEIS (August 13, 2002)  

Broader source: Energy.gov (indexed) [DOE]

3,2002 3,2002 REPLY TO ATTN OF: KEPR-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-82 Jeffrey Hathhorn Redmond Deputy Regional Manager - TFI/IDAHO FALLS Proposed Action: Vegetation Management for twenty-four Substations in the Burley District. See list of facilities under planning step 1). Location: See list of facilities under Planning Step 1. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes total vegetation management (bare ground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Burley District of the Idaho Falls Region. Analysis: The attached checklist shows the resources that were found during this analysis and what

438

(DOE/EIS-0285/SA-56): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 4/9/02  

Broader source: Energy.gov (indexed) [DOE]

09, 2002 09, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-56) 2ULRQ $OEUR 2O\PSLD 5HJLRQDO 0DQDJHU Proposed Action: Vegetation Management for the following electric yards located in the Ross District: Cape Horn North Bonneville Stevenson Carson Underwood Troutdale Cascade Locks Acton Ross 345kV and J.D. Alcoa Sifton St. Johns Ostrander McLoughlin Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to maintain a weed-free environment in the electrical substations located within the Olympia Region's Ross District. Description of the Proposal: BPA proposes to manage vegetation inside and around electrical

439

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-58) 5/31/02  

Broader source: Energy.gov (indexed) [DOE]

31, 2002 31, 2002 REPLY TO ATTN OF: KEPR-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-58) Bill Erickson - TPF/Walla Walla Natural Resource Specialist Proposed Action: Vegetation Management at the Lines Creek Microwave site. The proposed work will be accomplished within the fenced area of the facility. Location: The Lines Creek Microwave site is located at SWSW Section 33 T44N R2E within Shoshone County, Idaho, Walla Walla Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposed Action: BPA proposes bare ground vegetation management at the microwave site. Bare ground management is needed to prevent fire damage and maintain a vegetation free environment on the site.

440

(DOE/EIS-0285/SA-64): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 4/26/02  

Broader source: Energy.gov (indexed) [DOE]

6, 2002 6, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-64) Truman Conn - TFP Regional Manager, Walla Walla Region Proposed Action: Vegetation Management for Substations and Non-Electric Facilities in the Walla Walla Region (See Attachment A for a complete list of facilities) Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to manage vegetation inside and around electrical substations and associated facilities. Vegetation management within the substation shall include the bare ground management of all graveled areas. These areas shall primarily be maintained with the use of herbicides. The management of vegetation outside the substation and associated facilities

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Tests with a line-commutated converter as a variable inductive load on the Bonneville Power Administration transmission system  

SciTech Connect (OSTI)

A twelve-pulse, line-commutated converter, with a steady-state rating of 2.5 kV and 5.5 kA, formerly used for charging and discharging a superconducting magnet, was reconfigured as a static reactive power load. Tests staged at the Tacoma, WA, substation of the Bonneville Power Administration (BPA) revealed that the converter could be used as a variable inductive load, provided a stable current controller was installed. The unit was modulated as a variable VAR load following a sinusoidal VAR demand signal with an amplitude up to 14.8 MVAR. The total losses at maximum VAR output were 370 kW. This paper explains the necessary modifications of the converter to operate as a variable reactive load. Measured current waveshapes are analyzed. The effects of such a load on the BPA transmission system are presented.

Boenig, H.J.; Hauer, J.F.; Nielsen, R.G.

1986-01-01T23:59:59.000Z

442

(DOE/EIS-0285/SA-78): Supplement Analysis for the Transmission System Vegetation Management Program FEIS (07/01/02)  

Broader source: Energy.gov (indexed) [DOE]

2002 REPLY TO ATTN OF: KEPR-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-78) Randy Melzer Redmond Deputy Regional Manager - TFR/REDMOND Proposed Action: Vegetation Management for ten Substations in the Redmond District. (See list of facilities listed under planning step 1). Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes total vegetation management (bare ground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Redmond District of the Redmond Region. Analysis: The attached checklist shows the resources that were found during this analysis and what mitigation measures are required to protect those resources. In

443

(DOE/EIS-0285/SA-27): Supplement Analysis for the Transmission System Vegetation Management Program FEIS 10/22/01  

Broader source: Energy.gov (indexed) [DOE]

October 22, 2001 October 22, 2001 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-27) Ben Tilley - TFE/Alvey Natural Resource Specialist Proposed Action: Vegetation Management along the Marion-Alvey #1 from structure 14/5 to 64/3 and the Marion-Lane #1 from structure 14/5 to 70/2. Both lines describe the same segment of ROW between structures 14/5 and 45/2. Location: All ROW are located in Marion, Linn, and Lane Counties, OR, all being in the Eugene Region. Proposed by: Bonneville Power Administration (BPA), Eugene Region. Description of the Proposed Action: BPA proposes to clear unwanted vegetation in the rights-of- ways, around tower structures, and associated access roads that may impede the operation and

444

Transmission pricing of distributed multilateral energy transactions to ensure system security and guide economic dispatch  

E-Print Network [OSTI]

In this paper we provide a simulations-based demonstration of a hybrid electricity market that combines the distributed competitive advantages of decentralized markets with the system security guarantees of centralized ...

Ilic, Marija D.

2002-01-01T23:59:59.000Z

445

DC powerline communication system using a transmission line transformer for high degree of freedom applications  

E-Print Network [OSTI]

A new type of powerline communication is developed to reduce cable requirements for robotic, electromechanical, and vehicular systems. A DC power bus line connecting a DC power supply to motor drives and sensor units is ...

Wade, Eric R. (Eric Randolph), 1978-

2004-01-01T23:59:59.000Z

446

NREL: Transmission Grid Integration - Transmission Planning and Analysis  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission Planning and Analysis Transmission Planning and Analysis Thumbnail of map the United States that shows wind resources and transmission lines. Enlarge image This map shows the location of wind resources and transmission lines in the United States. See a larger image or state maps. NREL researchers are engaged in transmission planning and analysis to strengthen the electric power system through the integration of solar and wind power. As demand for electricity increases, electric power system operators must plan for and construct new generation and transmission lines. However, variable generation such as solar and wind power plants are often located far from the loads they serve. They depend on transmission lines to transport the electricity they produce to load centers. NREL is working with industry and utilities to address issues related to

447

Proceedings: commercial refrigeration research workshop. Summary  

SciTech Connect (OSTI)

The purpose of this workshop was to identify the state-of-the-art and determine research needs for improving energy use and demand in commercial refrigeration applications. Workshop attendees included research and development, technical operations and marketing people from manufacturers of supermarket refrigeration, space conditioning, and energy management systems equipment, and from supermarket chains and electric utilities. Presentations were given on best current practice and research needs from the perspective of each of these industry segments. Working groups identified ten important research, development and equipment demonstration projects to improve the efficiency of refrigerating equipment, heating, ventilating and air-conditioning (HVAC) equipment, and other energy-using systems in supermarkets.

Blatt, M.H.

1984-10-01T23:59:59.000Z

448

Thirteenth workshop on geothermal reservoir engineering: Proceedings  

SciTech Connect (OSTI)

PREFACE The Thirteenth Workshop on Geothermal Reservoir Engineering was held at Stanford University on January 19-21, 1988. Although 1987 continued to be difficult for the domestic geothermal industry, world-wide activities continued to expand. Two invited presentations on mature geothermal systems were a keynote of the meeting. Malcolm Grant presented a detailed review of Wairakei, New Zealand and highlighted plans for new development. G. Neri summarized experience on flow rate decline and well test analysis in Larderello, Italy. Attendance continued to be high with 128 registered participants. Eight foreign countries were represented: England, France, Iceland, Italy, New Zealand, Japan, Mexico and The Philippines. A discussion of future workshops produced a strong recommendation that the Stanford Workshop program continue for the future. There were forty-one technical presentations at the Workshop. All of these are published as papers in this Proceedings volume. Four technical papers not presented at the Workshop are also published. In addition to these forty five technical presentations or papers, the introductory address was given by Henry J. Ramey, Jr. from the Stanford Geothermal Program. The Workshop Banquet speaker was Gustavo Calderon from the Inter-American Development Bank. We thank him for sharing with the Workshop participants a description of the Bank???s operations in Costa Rica developing alternative energy resources, specifically Geothermal, to improve the country???s economic basis. His talk appears as a paper in the back of this volume. The chairmen of the technical sessions made an important contribution to the workshop. Other than Stanford faculty members they included: J. Combs, G. T. Cole, J. Counsil, A. Drenick, H. Dykstra, K. Goyal, P. Muffler, K. Pruess, and S. K. Sanyal. The Workshop was organized by the Stanford Geothermal Program faculty, staff and students. We would like to thank Marilyn King, Pat Oto, Terri Ramey, Bronwyn Jones, Yasmin Gulamani, and Rosalee Benelli for their valued help with the meeting arrangements and preparing the Proceedings. We also owe great thanks to our students who arranged and operated the audio-visual equipment, especially Jeralyn Luetkehans. The Thirteenth Workshop was supported by the Geothermal Technology Division of the U.S. Department of Energy through Contract No. DE-AS07-84ID12529. We deeply appreciate this continued support. Henry J. Ramey, Jr. Paul Kruger Roland N. Horne William E. Brigham Frank G. Miller Jean W. Cook

Ramey, H.J. Jr.; Kruger, P.; Horne, R.N.; Brigham, W.E.; Miller, F.G.; Cook, J.W. (Stanford Geothermal Program)

1988-01-21T23:59:59.000Z

449

Fuel Cell Technologies Office: DOE-DOD Shipboard APU Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DOE-DOD Shipboard APU Workshop DOE-DOD Shipboard APU Workshop The U.S. Department of Energy's (DOE) Fuel Cell Technologies Office participated in a Shipboard Auxiliary Power Unit (APU) Workshop hosted by the U.S. Department of Defense's (DOD) Office of Naval Research (ONR) on March 29 in Arlington, Virginia. Workshop objectives were to update the Navy, Military Sea Lift, and Maritime communities on the technical status of fuel cell development applicable to shipboard fuel cells, identify key opportunities for power generation systems, and prioritize associated system characteristics needed for transition. The workshop included an open discussion about user needs, limitations of existing design, and prioritization of next steps. Speakers included Precision Combustion Inc., UTC Power, FuelCell Energy, DOE, DOD, and ONR.

450

Event:Technical Workshop: Measurement, Reporting and Verification (MRV):  

Open Energy Info (EERE)

Workshop: Measurement, Reporting and Verification (MRV): Workshop: Measurement, Reporting and Verification (MRV): Experiences from and for implementation Jump to: navigation, search Calendar.png Technical Workshop: Measurement, Reporting and Verification (MRV): Experiences from and for implementation: on 2012/06/26 "The workshop will deal with MRV issues relevant to negotiators and practitioners from Partnership member countries and aims at contributing to an in-depth understanding of key aspects critical to the implementation of MRV-systems in developing countries. The workshop will focus on the "how" of implementing MRV-systems in a pragmatic, sustainable and cost-efficient way while taking advantage of existing structures and experiences. Thus the event wants to move beyond the political discussions

451

Hydrogen Sensor Workshop Agenda | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Sensor Workshop Agenda Hydrogen Sensor Workshop Agenda Agenda for the Hydrogen Sensor Workshop held June 8, 2011, in Chicago, Illinois.The workshop was hosted by the U.S....

452

Fuel Cells for Portable Power Workshop Proceedings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Fuel Cells for Portable Power Fuel Cells for Portable Power JoAnn Milliken Office of Transportation Technologies Office of Energy Efficiency and Renewable Energy U.S. Department of Energy 1000 Independence Avenue, SW Washington, DC 20585 202-586-2480 JoAnn.Milliken@ee.doe.gov January 15-17, 2002 Phoenix, AZ Presentation Outline * Why are we here? * DOE Transportation Fuel Cell Program * Workshop Objectives * Guidelines for Workshop Product * What have past DOE workshops achieved? Why are we here? Goal 300 10,000 Cost in $/kW 50kW system Today's low volume cost (1 unit) 2002 2010 Gasoline System Cost 50 Today's high volume cost (500,000 units) 1990 3,000 Government: Cost - the primary barrier to commercialization of PEMFCs for automobiles Industry: Business plans include fuel cells or fuel cell powered products

453

Relay coordination and protection failure effects on reliability indices in an interconnected sub-transmission system  

Science Journals Connector (OSTI)

Protection system failure is the main cause of cascading outages. It has been shown that the hidden failures lead to cascading outages. However, the effects of the coordination method as well as the hidden failure of the protection systems have not been investigated yet. In this paper, an algorithm based on sequential Monte Carlo simulation is proposed to find the reliability indices for different overcurrent relay coordination methods. The proposed algorithm is applied to the results of different relay coordination methods of a real network. The indices SAIFI, CAIDI, CAIFI and ENS for the results of different relay coordination methods are obtained strictly based on the contribution of the protection failure issues. Then, a comparison is made between the results of the different relay coordination methods in order to show how the coordination methods affect the reliability indices.

Kazem Mazlumi; Hossein Askarian Abyaneh

2009-01-01T23:59:59.000Z

454

California's electricity system of the future scenario analysis in support of public-interest transmission system R&D planning  

E-Print Network [OSTI]

TVA. Battery and compressed air energy storage systems haveenergy storage devices/methods include batteries, pumped hydro, and compressed air.

Eto, Joseph; Stovall, John P.

2003-01-01T23:59:59.000Z

455

RECIPIENT:Princeton Power Systems STATE: NJ PROJECT Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage  

Broader source: Energy.gov (indexed) [DOE]

Princeton Power Systems Princeton Power Systems STATE: NJ PROJECT Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage TITLE: Funding Opportunity Announcement Number Procurement Instrument Number NEPA Control Number cm Number DE-FOA-0000293 DE-EE0003640 GFO-000364~001 GOO Based on my review of the information concerning the proposed action, as NEPA Compliance Officer (authorized under DOE Order 451.1A), I have made the foUowing determination: CX, EA, EIS APPENDIX AND NUMBER: Description: A9 Information gathering (including, but not limited to, ~terature surveys, inventories, audits), data analysis (including computer modeling), document preparation (such as conceptual design or feasibility studies, analytical energy supply

456

California Energy Commission Public Interest Energy Research/Energy System Integration -- Transmission-Planning Research & Development Scoping Project  

E-Print Network [OSTI]

California Energy Commission Transmission Planning Analysis92, No. 5, Dec. CEC (California Energy Commission). 2004.of MCPs. California Energy Commission. Nov. CERTS PIER

Eto, Joseph H.; Lesieutre, Bernard; Widergren, Steven

2004-01-01T23:59:59.000Z

457

Archeology Workshop Draft Agenda  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

SSRL27 Users' Meeting | Workshops | Registration | SSRL Home Page SSRL27 Users' Meeting | Workshops | Registration | SSRL Home Page Application of Synchrotron Techniques to Materials Issues in Art and Archeology October 18, 2000 Stanford Synchrotron Radiation Laboratory, SLAC Panofsky Auditorium Organizers: Russell Chianelli (University of Texas at El Paso) Nicholas Pingitore (University of Texas at El Paso) Herman Winick (SSRL) Materials -- bones, artifacts, artwork -- lie at the heart of both archaeology and art conservation. Synchrotron radiation techniques provide powerful new ways to interrogate these records of our physical and cultural past -- if we know the right questions to ask and how to ask them. The purpose of this workshop is to discuss and explore the current and potential applications of synchrotron science to problems in archaeology and art conservation. Bringing together key members of the synchrotron and archaeology/art communities, the interdisciplinary workshop will report their latest research accomplishments, highlight ongoing projects, and catalyze new interactions between these fields.

458

Structure Breakdown Workshop Schedule  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Breakdown Breakdown Workshop SLAC, Orange Room August 28 - 30 , 2000 Announcement Workshop Poster Workshop Goals: The Goal of the workshop is to review understanding of warm structure breakdown phenomena, to define common terms for comparing tests and to identify avenues for further study. For a partial bibliography, please view the following URL : http://www-project.slac.stanford.edu/lc/wkshp/RFBreakdwn/references/publist.htm Schedule and Presentations: Monday, August 28 8:30 - Operation Experience and Definition of Problem Moderator - G. Loew (initial questions) Opening remarks and introduction (C. Adolphsen) (15min) CERN Structure Operation Results (W. Wuensch) (30 min) NLCTA Structure Operation Results (C. Adolphsen) (30 min) ASTA Structure Operation Results (R. Loewen) (20 min)

459

Onboard Storage Tank Workshop  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy (DOE) and Sandia National Laboratories co-hosted the Onboard Storage Tank Workshop on April 29th, 2010. Onboard storage tank experts gathered to share lessons learned...

460

NWHA Fall Workshop & Tour  

Broader source: Energy.gov [DOE]

This years Fall Regional Workshop on October 30 will focus on extending the longevity of our legacy hydropower projects through upgrades, refurbishment and life extensions, while meeting needs of...

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Membrane Technology Workshop  

Broader source: Energy.gov [DOE]

At the Membrane Technology Workshop (held July 24, 2012, in Rosemont, IL), stakeholders from industry and academia explored the status of membrane research and development (R&D). Participants...

462

Transportation Management Workshop: Proceedings  

SciTech Connect (OSTI)

This report is a compilation of discussions presented at the Transportation Management Workshop held in Gaithersburg, Maryland. Topics include waste packaging, personnel training, robotics, transportation routing, certification, containers, and waste classification.

Not Available

1993-10-01T23:59:59.000Z

463

Past Workshops and Events  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy (DOE) hosts workshops, conferences, roundtables, and other meetings related to solid-state lighting (SSL) to provide a forum for information exchange and updates on...

464

D&D Workshops  

Broader source: Energy.gov [DOE]

D&D Workshops present a setting for members of the deactivation and decommissioning community of practice to come together to address focused cleanup issues. In their pursuit of innovative...

465

Membrane Technology Workshop  

Broader source: Energy.gov [DOE]

At the Membrane Technology Workshop (held July 24, 2012, in Rosemont, IL), stakeholders from industry and academia explored the status of membrane research and development (R&D). Participants ...

466

Multimaterial Joining Workshop  

Broader source: Energy.gov [DOE]

At the Multimaterial Joining Workshop (held in Chicago, IL, on July 23, 2012), subject matter experts from industry and academia described their views on state-of-the-art technologies, opportuniti...

467

Meetings and Workshops Archive  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Tuesday, June 18, 2013 * Location TBD 9:00 a.m.-17:00 p.m. Workshop to take place during SRI 2013 in Washington, D.C., June 19-21, 2013 2013 IEEE International Symposium on...

468

Quadrennial Technology Review's Alternative Generation Workshop...  

Broader source: Energy.gov (indexed) [DOE]

Workshop Slides Preliminary Slides for Alternative Generation Workshop including Carbon Capture and Sequestration, Nuclear Power, Wind Power, Water Power, Geothermal...

469

International Hydrogen Infrastructure Challenges Workshop Summary...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

International Hydrogen Infrastructure Challenges Workshop Summary - NOW, NEDO, and DOE International Hydrogen Infrastructure Challenges Workshop Summary - NOW, NEDO, and DOE...

470

Demonstration and Deployment Strategy Workshop | Department of...  

Broader source: Energy.gov (indexed) [DOE]

Demonstration and Deployment Strategy Workshop Demonstration and Deployment Strategy Workshop The Bioenergy Technologies Office's (BETO's) Demonstration and Deployment Strategy...

471

NREL: Transmission Grid Integration - Webinars  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Webinars Webinars Want updates about future transmission grid integration webinars and publications? Join our mailing list. NREL periodically offers webinars on transmission grid integration topics to provide insight into its research. Explore the resources below to learn more. Upcoming Webinars Please check back. Details on future meetings and workshops will be posted as they are available. Past Webinars Results from The Western Wind and Solar Integration Study Phase 2: An examination of how wind and solar power affect operations, costs, and emissions from fossil-fueled generators Wednesday, September 25, 2013 at 12:00 EDT (10:00 MDT) The Western Wind and Solar Integration Study Phase 2 (WWSIS-2), launched in 2011, examines the potential impacts of up to 33% wind and solar energy

472

Delay-aware BS Discontinuous Transmission Control and User Scheduling for Energy Harvesting Downlink Coordinated MIMO Systems  

E-Print Network [OSTI]

In this paper, we propose a two-timescale delay-optimal base station Discontinuous Transmission (BS-DTX) control and user scheduling for downlink coordinated MIMO systems with energy harvesting capability. To reduce the complexity and signaling overhead in practical systems, the BS-DTX control is adaptive to both the energy state information (ESI) and the data queue state information (QSI) over a longer timescale. The user scheduling is adaptive to the ESI, the QSI and the channel state information (CSI) over a shorter timescale. We show that the two-timescale delay-optimal control problem can be modeled as an infinite horizon average cost Partially Observed Markov Decision Problem (POMDP), which is well-known to be a difficult problem in general. By using sample-path analysis and exploiting specific problem structure, we first obtain some structural results on the optimal control policy and derive an equivalent Bellman equation with reduced state space. To reduce the complexity and facilitate distributed imp...

Cui, Ying; Wu, Yueping

2012-01-01T23:59:59.000Z

473

Blackout 2003: Transcript of Technical Conference with the Electric System  

Broader source: Energy.gov (indexed) [DOE]

Transcript of Technical Conference with the Electric Transcript of Technical Conference with the Electric System Investigation Team Blackout 2003: Transcript of Technical Conference with the Electric System Investigation Team Electric System Investigation Team: 8 Reliability Recommendation consultation Transcript of the technical conference sponsored by the U.S. Canada task force investigating the August 14, 2003 blackout across Canada and the Northeastern United States. The transcript includes reports and discussions from the Electric System Investigation team on reliability recommendations. ELECTRIC SYSTEM INVESTIGATION TEAM : 8 RELIABILITY RECOMMENDATION CONSULTATION More Documents & Publications 2009 National Electric Transmission Congestion Study - Oklahoma City Workshop 2009 National Electric Transmission Congestion Study - San Francisco

474

1406 IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 22, NO. 4, NOVEMBER 2007 Market-Based Coordination of Transmission  

E-Print Network [OSTI]

with competitive generation capacity planning in electricity markets. The purpose of the model is a holistic simulation of generation and transmission capacity expansion in the market environment. The solution a joint energy and transmission auction market and a capacity mechanism. The joint auction market enables

Fu, Yong

475

NETL Publications: 12th Annual SECA Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

12th Annual SECA Workshop 12th Annual SECA Workshop July 26-28, 2011 Table of Contents Disclaimer Presentations Poster Presentations PRESENTATIONS Plenary Talks Moderator: Heathther Quedenfeld Welcome and Introduction Heather Quedenfeld, Division Director, Power Systems National Energy Technology Laboratory Presentation [PDF-759KB] Overview of DOE SECA Program Shailesh Vora, Technology Manager for Fuel Cells National Energy Technology Laboratory Presentation [PDF-2.07MB] Distributed Generation - A Utility Perspective Ram Sastry, Director - Research & Technology, Customer & Distribution Services American Electric Power Presentation [PDF-2.42MB] Critical Materials for SOFC Jan Thijssen, President, J. Thijssen, LLC Presentation [PDF-922KB] Analysis of SOFC Plant Configurations with CCS

476

PRIVACY IMPACT ASSESSMENT: Integrated Safety Management Workshop  

Broader source: Energy.gov (indexed) [DOE]

Integrated Integrated Safety Management Workshop Registration PIA Template Version 3 - May, 2009 Department of Energy Privacy Impact Assessment (PIA) Guidance is provided in the template. See DOE Order 206.1, Department of Energy Privacy Program, Appendix A, Privacy Impact Assessments, for requirements and additional guidance for conducting a PIA: http://www.directives.doe.gov/pdfs/doe/doetextlneword/206/o2061.pdf Please complete electronically: no hand-written submissions will be accepted. This template may not be modified. MODULE 1- PRIVACY NEEDS ASSESSMENT Date Departmental Element&·Slte 16/Jun/09 Idaho National Laboratory Engineering Research Office Building (EROB) Name of-Information System or IT Project Integrated Safety Management Workshop Registration Exhibit Project UID 207765 NewPIA D Update 0 DOE PIA - ISMS Workshop Finallxw.doc N T "tl I

477

DOE Light Duty Vehicle Workshop  

Broader source: Energy.gov [DOE]

On July 26, 2010, the U.S. Department of Energy (DOE) sponsored a Light Duty Vehicle Workshop in Washington, D.C. Presentations from this workshop appear below as Adobe Acrobat PDFs.

478

Message from the workshop chairs  

Science Journals Connector (OSTI)

A warm welcome to the sixth edition of the IEEE International Workshop on Autonomic and Opportunistic Communications (AOC 2012). This workshop follows the highly successful editions in the past few years, which have made AOC a highly popular event for ...

Chiara Boldrini; Merkouris Karariopoulos

2012-06-01T23:59:59.000Z

479

Tribal Energy NEPA Fundamentals Workshop  

Office of Energy Efficiency and Renewable Energy (EERE)

The Tribal Energy NEPA Fundamentals Workshop is a three-day workshop for tribes to understand how to manage the National Environmental Policy Act (NEPA) process and implement the Council on...

480

Hydrogen Technology Education Workshop Proceedings  

Fuel Cell Technologies Publication and Product Library (EERE)

This document outlines activities for educating key target audiences, as suggested by workshop participants. Held December 4-5, 2002, the Hydrogen Technology Education Workshop kicked off a new educat

Note: This page contains sample records for the topic "transmission system workshop" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Next Generation Light Source Workshops  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Next Generation Light Source Workshops A series of workshops will be held in late August with the goal of refining the scientific drivers for the facility and translating the...

482

Sandia National Laboratories: Transmission Grid Integration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Infrastructure Security, Modeling, Modeling & Analysis, News, News & Events, Renewable Energy, SMART Grid, Systems Analysis, Transmission Grid Integration, Wind Energy Sandia...

483

Open Access Transmission Tariff  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission | OATT Transmission | OATT Skip Navigation Links Transmission Functions Infrastructure projects Interconnection OASIS OATT Western Open Access Transmission Service Tariff Revision Western Area Power Administration submitted its revised Open Access Transmission Service Tariff with the Federal Energy Regulatory Commission on Sept. 30, 2009. The tariff became effective on Dec. 1, 2009, as modified by Western's March 2, 2011 compliance filing. The revised tariff was developed to comply with FERC Order No. 890 and to be consistent with Western's statutory and regulatory requirements. It addresses changes in transmission services and planning. FERC issued an order on Dec. 2, 2010, granting Western's petition for a Declaratory Order approving the tariff as an acceptable reciprocity tariff, subject to Western making a compliance filing within 30 days to address items in Attachment C, Attachment P and Attachment Q. Western made its compliance filing on March 2, 2010, addressing FERC's Dec. 2, 2010, order. FERC accepted Western's March 2, 2011 compliance filing on April 25, 2011. Western has made several ministerial filings to its OATT as part of FERC's eTariff viewer system, the last of these was approved on March 29, 2013. Further detail can be found in the links below.Current OATT

484

Tenth workshop on geothermal reservoir engineering: proceedings  

SciTech Connect (OSTI)

The workshop contains presentations in the following areas: (1) reservoir engineering research; (2) field development; (3) vapor-dominated systems; (4) the Geysers thermal area; (5) well test analysis; (6) production engineering; (7) reservoir evaluation; (8) geochemistry and injection; (9) numerical simulation; and (10) reservoir physics. (ACR)

Not Available

1985-01-22T23:59:59.000Z

485

EERE QC Workshop Agenda December 910, 2013  

E-Print Network [OSTI]

EERE QC Workshop Agenda December 9­10, 2013 NREL, Energy Systems Integration Facility Monday Technologies Laboratory Program Manager, NREL 8:50 EERE welcome: Nancy Garland, FCTO; Joe Cresko, AMO 9 of current QC activities in EERE: Cassidy Houchins, SRA 11:05 Industry panel: Quality control for clean

486

(DOE/EIS-0285-SA-115): Supplement Analysis for the Transmission System Vegetation Management Program FEIS, Shelton-Fairmount # 1-4 12/20/02  

Broader source: Energy.gov (indexed) [DOE]

0, 0, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA 115, Shelton- Fairmount # 1-4. James A. Jellison - TFO/Olympia Proposed Action: Vegetation Management along the Shelton Fairmount # 1-4 230kV & 115kV transmission lines corridor from structure 34/3 through structure 60/2 (reference line ADNO 8354). Right of way width averages 258 feet. Location: The project area is located in Jefferson County, Washington. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of- way, access roads and around tower structures along the subject transmission line corridors. Approximately 26 miles of right-of-way will be treated using selective and non-selective methods that include hand cutting, mowing and

487

(DOE/EIS-0285/SA-121): Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-121): 2/12/03  

Broader source: Energy.gov (indexed) [DOE]

2, 2003 2, 2003 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-121 Murry-Custer No. 1 Don Atkinson - TFN/Snohomish Proposed Action: Vegetation Management along the Murry-Custer No.1 transmission line from structure 1/1 through structure 6/2. Corridor width is 125 feet. Location: The project area is located within Snohomish County, Washington. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of- way, access roads and around tower structures along the subject transmission line corridor. Approximately 77.5 acres of right-of-way, 6 miles of access road, and 48 structure sites will be

488

(DOE/EIS-0285/SA-110): Supplement Analysis for the Transmission System Vegetation Management Program FEIS-Covington-Columbia No. 3) 10/2/02  

Broader source: Energy.gov (indexed) [DOE]

2, 2, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS DOE/EIS-0285/SA-110-Covington-Columbia No. 3 Don Atkinson - TFN/Snohomish Proposed Action: Vegetation Management along the Covington-Columbia No. 3, 230kV transmission lines from structure 1/1 through structure 12/1. Corridor width varies from 150 feet to 537.5 feet. The project area is located within King County, Washington. Location: The project area is located within King County, Washington. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of-way, access roads and around tower structures along the subject transmission line corridor. Approximately 568.4 acres of the right-of-way will be treated using selective and non-selective methods that include

489

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA- 129) Ashe-Marion #2 [Mile 150-157]  

Broader source: Energy.gov (indexed) [DOE]

7, 2003 7, 2003 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA- 129 Ashe-Marion #2 [Mile 150-157] Elizabeth Johnson Natural Resource Specialist- TFR/The Dalles Proposed Action: Vegetation Management for the Ashe-Marion #2 500 kV transmission line from structure 150/2 through structure 157/7 (reference line). The Buckley-Marion #1 transmission line is also present within the proposed corridor. Right of way width averages 135 feet. Location: The project location is within Wasco County, Oregon near the city of Pine Grove, and is within the Redmond Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of-

490

(DOE/EIS-0285/SA-99): Supplement Analysis for the Transmission System Vegetation Management Program FEIS -Olympia-Grand Coulee No.1 8/29/02  

Broader source: Energy.gov (indexed) [DOE]

9, 9, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-99-Olympia-Grand Coulee No. 1 Don Atkinson - TFN/Snohomish Proposed Action: Vegetation Management along the Olympia-Grand Coulee No. 1, 287 kV transmission line from structure 53/4 through structure 64/1. Corridor width is 125 feet. Location: The project area is located within King County, Washington. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of-way, access roads and around tower structures along the subject transmission line corridor. Approximately 163 acres will be treated using selective and non-selective methods that include hand cutting, mowing and herbicide treatments. Vegetation management is required for unimpeded

491

(DOE/EIS-0285/SA-114): Supplement Analysis for the Transmission System Vegetation Management Program EIS (Chehalis-Raymond #1, ADNO 8114) 12/5/02  

Broader source: Energy.gov (indexed) [DOE]

December December 5, 2002 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-114) (Chehalis-Raymond #1, ADNO 8114) Jim Jellison - TFO/Olympia Natural Resource Specialist Proposed Action: Vegetation Management for portion of the Chehalis-Raymond #1 115 kV transmission line Location: Project location is within Lewis and Pacific counties, Washington and is within the Olympia Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to clear targeted vegetation within the Right-of- Ways along access roads and around towers that may impede the operation and maintenance of the subject transmission lines. See Section 1.4 of the attached checklists for a complete description of the proposed action. Analysis: Please see the attached checklist for the resources

492

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-132 (Big Eddy-Ostrander #1)(3/19/03)  

Broader source: Energy.gov (indexed) [DOE]

9, 2003 9, 2003 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-132 (Big Eddy-Ostrander #1) Libby Johnson Natural Resource Specialist - TFR/THE DALLES Proposed Action: Vegetation Management for portion of the Big Eddy - Ostrander #1 500 kV transmission line located from tower structure 31/2 to 39/3. Location: Project location is in BPA Redmond Region in Hood River County, Oregon. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to clear targeted vegetation within the Right-of- Ways along access roads and around towers that may impede the operation and maintenance of the subject transmission lines. See Section 1.4 of the attached checklists for a complete

493

(DOE/EIS-0285/SA-113-1): Supplement Analysis for the Transmission System Vegetation Management Program Updates 9/27/02 SA-113 12/2/02  

Broader source: Energy.gov (indexed) [DOE]

12/02/02 12/02/02 REPLY TO ATTN OF: KEC-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program (DOE/EIS-0285/SA-113-1) Updates 9/27/02 SA-113 Bill Erickson, TFP/Walla Walla Natural Resource Specialist Proposed Action: To perform remedial vegetation management for keeping vegetation a safe distance away from electric power facilities and controlling noxious weeds within a section of BPA's Big Eddy-Ostrander Transmission Corridor. During a site review conducted in late fall of 2001, the inspector observed various species of hardwood trees resprouted from stumps. The new vegetative growth encroached on the required "Minimum Safe Distance" between the top of vegetation and the conductor cables. The management action is necessary to reduce the current and potential future hazards that tall- growing vegetation poses to transmission

494

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-149-Captain Jack-Malin #1)  

Broader source: Energy.gov (indexed) [DOE]

8, 2003 8, 2003 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-149-Captain Jack-Malin #1) Elizabeth Johnson Natural Resource Specialist - TFR/The Dalles Proposed Action: Vegetation Management for the Captain Jack-Malin #1 500 kV transmission line from structure 2/4 to Malin Substation (reference line). Right of way width averages 150 feet. Location: The project location is within Klamath County, Oregon near the city of Malin, and is within the Redmond Region. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of- way, access roads and around tower structures along the subject transmission line corridors.

495

(DOE/EIS-0285/SA 118): Supplement Analysis for the Transmission System Vegetation Management Program EIS, Holcomb-Naselle 115kV)  

Broader source: Energy.gov (indexed) [DOE]

7, 2003 7, 2003 REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-SA 118, Holcomb - Naselle 115 kV. James A. Jellison - TFO/Olympia Proposed Action: Vegetation Management along the Holcomb Naselle 115kV transmission line corridor from structure 1/1 through structure 21/10. Right of way width averages 100 feet. Location: The project area is located in Pacific County, Washington. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of- way, access roads and around tower structures along the subject transmission line corridor. Approximately 21 miles of right-of-way will be treated using selective and non-selective

496

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-130- Keeler-Tillamook)(3/10/03)  

Broader source: Energy.gov (indexed) [DOE]

0, 2003 0, 2003 REPLY TO ATTN OF: KEP/4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-130- Keeler-Tillamook) Mark Newbill Natural Resource Specialist- TFE/Chemawa Proposed Action: Vegetation Management for the Keeler Tillamook 115 kV transmission line from structure 1/7 through structure 58/2, and along adjacent portions of the Keeler-Forest Grove #2 115KV transmission line. In addition the project includes 11miles of the 115KV Timber Tap. Location: The project is located in the BPA Eugene Region, Tillamook and Washington Counties, Oregon. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to remove unwanted vegetation along the right-of-

497

Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-146-Custer-Ingledow No.1&2  

Broader source: Energy.gov (indexed) [DOE]

REPLY TO ATTN OF: KEP-4 SUBJECT: Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-146-Custer-Ingledow No.1&2 Don Atkinson Natural Resource Specialist - TFN/Snohomish Proposed Action: Vegetation Management for portion of the Custer-Ingledow No.1&2 500 kV transmission line located from tower structure 1/4 to 9/6. Location: Project location is in BPA Snohomish Region in Whatcom County, Washington. Proposed by: Bonneville Power Administration (BPA). Description of the Proposal: BPA proposes to clear targeted vegetation within the Right-of- Ways along access roads and around towers that may impede the operation and maintenance of the subject transmission lines. See Section 1.4 of the attached checklists for a complete

498

Workshop: Photovoltaics Research and Development Beyond SunShot...  

Broader source: Energy.gov (indexed) [DOE]

W) for utility-scale systems. The PV R&D Beyond SunShot workshop will include short primer talks on the future of the PV market and PV technology, followed by small and large...

499

Graduate School Grant Workshop Series  

E-Print Network [OSTI]

Graduate School Grant Workshop Series Fall 2012 Quantitative Social Sciences #12;Overview Brief Review from Intro Workshop Goals for This Workshop Steps to Successful Grant Writing The "Writing" Part of Grant Writing Climate for Funding of Social Sciences Research Resources Tips Next Steps #12

Omiecinski, Curtis

500

Federal Register Notice: Plan for Conduct of 2012 Electric Transmission  

Broader source: Energy.gov (indexed) [DOE]

Notice: Plan for Conduct of 2012 Electric Notice: Plan for Conduct of 2012 Electric Transmission Congestion Study Federal Register Notice: Plan for Conduct of 2012 Electric Transmission Congestion Study November 10, 2011 - 1:42pm Addthis The Department has issued a Federal Register Notice initiating preparations for development of the 2012 National Electric Transmission Congestion Study. The Department is seeking comments on what publicly-available data and information should be considered, and what types of analysis should be performed to identify and understand the significance and character of transmission congestion. DOE will host four regional pre-study workshops in early December 2011 to receive input and suggestions concerning the study. Addthis Related Articles 2012 Congestion Study Workshops to be Held in December; Agendas Now