Powered by Deep Web Technologies
Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Transmission Electron Microscope and Scanning Electron Microscopes -  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Facilities > Transmission Electron Facilities > Transmission Electron Microscope and Scanning Electron Microscopes FACILITIES Transmission Electron Microscope and Scanning Electron Microscopes Overview Other Facilities Work with Argonne Contact us For Employees Site Map Help Join us on Facebook Follow us on Twitter NE on Flickr Transmission Electron Microscope and Scanning Electron Microscopes The research activities of the Corrosion and Mechanics of Materials Section are supported by complete metallography/sample preparation rooms equipped with several optical and electron microscopes: a Transmission Electron Microscope and two Scanning Electron Microscopes. Bookmark and Share Transmission electron microscope (TEM) Detail of JEOL 100CXII TEM Figure 1: Detail of JEOL 100CXII TEM. Click on image to view larger image.

2

Electron microscopy and microanalysis Two transmission electron microscopes  

E-Print Network [OSTI]

Electron microscopy and microanalysis Two transmission electron microscopes (TEM) and three scanning electron micro- scopes (SEM) are operated by the De- partment. Attachments for TEM include energy dispersive X-ray spectrometer (EDS), scanning transmission attachment, serial electron energy loss

3

Instrument Series: Microscopy Environmental Transmission Electron Microscope  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Environmental Transmission Environmental Transmission Electron Microscope EMSL's environmental transmission electron microscope (ETEM) provides in situ capabilities that enable atomic-resolution imaging and spectroscopic studies of materials under dynamic operating conditions. In contrast to traditional operation of TEM under high vacuum, EMSL's ETEM uniquely allows imaging within high- temperature and gas environments-with a gas pressure up to 20 Torr. With a spherical aberration corrector for the objective lens, the ETEM captures atomic-level processes as they occur, enabling vital research across a range of scientific fields. Research Applications Chemical science and engineering - providing in situ observation of catalytic processes with atomic-level resolution Materials science and engineering - allowing

4

Ponderomotive phase plate for transmission electron microscopes  

DOE Patents [OSTI]

A ponderomotive phase plate system and method for controllably producing highly tunable phase contrast transfer functions in a transmission electron microscope (TEM) for high resolution and biological phase contrast imaging. The system and method includes a laser source and a beam transport system to produce a focused laser crossover as a phase plate, so that a ponderomotive potential of the focused laser crossover produces a scattering-angle-dependent phase shift in the electrons of the post-sample electron beam corresponding to a desired phase contrast transfer function.

Reed, Bryan W. (Livermore, CA)

2012-07-10T23:59:59.000Z

5

A transmission electron microscope for lecture demonstrations  

Science Journals Connector (OSTI)

A simple transmission electron microscope (TEM) suitable for lecture demonstrations is described. In this TEM electrons are created in a glow discharge between two parallel electrodes in air at a reduced pressure. The electrons are collimated by a small hole in the anode focused by a solenoid that acts as an electromagnetic lens and imaged on a thin layer of phosphor deposited inside an Erlenmeyer flask. An image of a biological sample placed between the source and the lens can be magnified about 20 times. The microscope uses inexpensive components that can be quickly assembled during a demonstration. The TEM provides a visual and memorable display that highlights phenomena such as mean-free-path charged particle optics electrical discharges and cathodoluminescence.

J. A. Panitz; Gertrude Rempfer

2006-01-01T23:59:59.000Z

6

Dynamics of a nanodroplet under a transmission electron microscope  

SciTech Connect (OSTI)

We investigate the cyclical stick-slip motion of water nanodroplets on a hydrophilic substrate viewed with and stimulated by a transmission electron microscope. Using a continuum long wave theory, we show how the electrostatic stress imposed by non-uniform charge distribution causes a pinned convex drop to deform into a toroidal shape, with the shape characterized by the competition between the electrostatic stress and the surface tension of the drop, as well as the charge density distribution which follows a Poisson equation. A horizontal gradient in the charge density creates a lateral driving force, which when sufficiently large, overcomes the pinning induced by surface heterogeneities in the substrate disjoining pressure, causing the drop to slide on the substrate via a cyclical stick-slip motion. Our model predicts step-like dynamics in drop displacement and surface area jumps, qualitatively consistent with experimental observations.

Leong, Fong Yew, E-mail: leongfy@ihpc.a-star.edu.sg [A-STAR Institute of High Performance Computing, 1 Fusionopolis Way, Connexis, Singapore 138632 (Singapore); Mirsaidov, Utkur M. [Department of Physics, National University of Singapore, 2 Science Drive 3, Singapore 117551 (Singapore); Center for BioImaging Sciences, National University of Singapore, Science Drive 4, Singapore 117543 (Singapore); Matsudaira, Paul [Center for BioImaging Sciences, National University of Singapore, Science Drive 4, Singapore 117543 (Singapore); MechanoBiology Institute, National University of Singapore, 5A Engineering Drive 1, Singapore 117411 (Singapore); Department of Biological Sciences, National University of Singapore, 14 Science Drive 4, Singapore 117543 (Singapore); Singapore-MIT Alliance for Research and Technology Center, Science Drive 2, Singapore 117543 (Singapore); Mahadevan, L. [School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138, USA and Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States)

2014-01-15T23:59:59.000Z

7

CFN | Hitachi HD2700C Scanning Transmission Electron Microscope  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

spectroscopy (EELS) can be as small as 0.35 eV, due to its cold field emission electron gun (FEG) and the presence of a high-resolution parallel EELS detector (Gatan Enfina-ER)....

8

Quantifying Transient States in Materials with the Dynamic Transmission Electron Microscope  

SciTech Connect (OSTI)

The Dynamic Transmission Electron Microscope (DTEM) offers a means of capturing rapid evolution in a specimen through in-situ microscopy experiments by allowing 15 ns electron micrograph exposure times. The rapid exposure time is enabled by creating a burst of electrons at the emitter by ultraviolet pulsed laser illumination. This burst arrives a specified time after a second laser initiates the specimen reaction. The timing of the two Q-switched lasers is controlled by high-speed pulse generators with a timing error much less than the pulse duration. Both diffraction and imaging experiments can be performed, just as in a conventional TEM. The brightness of the emitter and the total current control the spatial and temporal resolutions. We have demonstrated 7 nm spatial resolution in single 15 ns pulsed images. These single-pulse imaging experiments have been used to study martensitic transformations, nucleation and crystallization of an amorphous metal, and rapid chemical reactions. Measurements have been performed on these systems that are possible by no other experimental approaches currently available.

Campbell, G; LaGrange, T; Kim, J; Reed, B; Browning, N

2009-09-21T23:59:59.000Z

9

Development of a surface conductivity measurement system for ultrahigh vacuum transmission electron microscope  

SciTech Connect (OSTI)

The surface conductivity measurement system using a micro-four-point probe (M4PP) had been developed for the ultrahigh vacuum transmission electron microscope (UHV-TEM). Since the current distribution in the sample crystals during the current voltage measurement by the M4PP is localized within the depth of several micrometers from the surface, the system is sensitive to the surface conductivity, which is related with the surface superstructure. It was installed in the main chamber of the TEM and the surface conductivity can be measured in situ. The surface structures were observed by reflection electron microscopy and diffraction (REM-RHEED). REM-RHEED enables us to observe the surface superstructures and their structure defects such as surface atomic steps and domain boundaries of the surface superstructure. Thus the effects of the defects on the surface conductivity can be investigated. In the present paper we present the surface conductivity measurement system and its application to the Si(111)-{radical}(3)x{radical}(3)-Ag surface prepared on the Si(111) vicinal surfaces. The result clearly showed that the surface conductivity was affected by step configuration.

Minoda, H. [Department of Applied Physics, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi, Saitama 332-0012 (Japan); Hatano, K.; Yazawa, H. [Department of Applied Physics, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 (Japan)

2009-11-15T23:59:59.000Z

10

Towards 0.1 nm resolution with the first spherically corrected transmission electron microscope  

Science Journals Connector (OSTI)

......defocus-modulation image processing. Ultramiaysco/y'41: 323-333. means of an appropriate monochromator. 24 Thust A, Overwijk M H, Coene W M J, and Lentzen M (1996) M. Haider et al. Corrected electron microscope 405 Numerical correction of lenaberrations......

Maximilian Haider; Herald Rose; Stephan Uhlemann; Bernd Kabius; Knut Urban

1998-01-01T23:59:59.000Z

11

Microcalorimeter-type energy dispersive X-ray spectrometer for a transmission electron microscope  

Science Journals Connector (OSTI)

......Microscopy (1986) New York: Plenum Press. 4...Garratt-Reed A J , Bell D C. Energy-Dispersive X-ray...Microscopy (1996) New York: Plenum Press. 19...Microcalorimeter-type energy dispersive X-ray...electron microscope. | A new energy dispersive......

Toru Hara; Keiichi Tanaka; Keisuke Maehata; Kazuhisa Mitsuda; Noriko Y. Yamasaki; Mitsuaki Ohsaki; Katsuaki Watanabe; Xiuzhen Yu; Takuji Ito; Yoshihiro Yamanaka

2010-02-01T23:59:59.000Z

12

High precision two-dimensional strain mapping in semiconductor devices using nanobeam electron diffraction in the transmission electron microscope  

SciTech Connect (OSTI)

A classical method used to characterize the strain in modern semiconductor devices is nanobeam diffraction (NBD) in the transmission electron microscope. One challenge for this method lies in the fact that the smaller the beam becomes, the more difficult it becomes to analyze the resulting diffraction spot pattern. We show that a carefully designed fitting algorithm enables us to reduce the sampling area for the diffraction patterns on the camera chip dramatically (?1/16) compared to traditional settings without significant loss of precision. The resulting lower magnification of the spot pattern permits the presence of an annular dark field detector, which in turn makes the recording of images for drift correction during NBD acquisition possible. Thus, the reduced sampling size allows acquisition of drift corrected NBD 2D strain maps of up to 3000 pixels while maintaining a precision of better than 0.07%. As an example, we show NBD strain maps of a modern field effect transistor (FET) device. A special filtering feature used in the analysis makes it is possible to measure strain in silicon devices even in the presence of other crystalline materials covering the probed area, which is important for the characterization of the next generation of devices (Fin-FETs).

Baumann, Frieder H., E-mail: fhbauman@us.ibm.com [IBM Microelectronics Division, 2070 Route 52, Hopewell Junction, New York 12533 (United States)

2014-06-30T23:59:59.000Z

13

Real-time studies of battery electrochemical reactions inside a transmission electron microscope.  

SciTech Connect (OSTI)

We report the development of new experimental capabilities and ab initio modeling for real-time studies of Li-ion battery electrochemical reactions. We developed three capabilities for in-situ transmission electron microscopy (TEM) studies: a capability that uses a nanomanipulator inside the TEM to assemble electrochemical cells with ionic liquid or solid state electrolytes, a capability that uses on-chip assembly of battery components on to TEM-compatible multi-electrode arrays, and a capability that uses a TEM-compatible sealed electrochemical cell that we developed for performing in-situ TEM using volatile battery electrolytes. These capabilities were used to understand lithiation mechanisms in nanoscale battery materials, including SnO{sub 2}, Si, Ge, Al, ZnO, and MnO{sub 2}. The modeling approaches used ab initio molecular dynamics to understand early stages of ethylene carbonate reduction on lithiated-graphite and lithium surfaces and constrained density functional theory to understand ethylene carbonate reduction on passivated electrode surfaces.

Leung, Kevin; Hudak, Nicholas S.; Liu, Yang; Liu, Xiaohua H.; Fan, Hongyou; Subramanian, Arunkumar; Shaw, Michael J.; Sullivan, John Patrick; Huang, Jian Yu

2012-01-01T23:59:59.000Z

14

Background, status and future of the Transmission Electron Aberration-corrected Microscope project  

Science Journals Connector (OSTI)

...Microscope project Recent advances in aberration-correcting...DOEs) Office of Science to jointly design...great interest for aerospace and cryogenic applications...be possible to advance to a new level...heart of materials science. At this level...

2009-01-01T23:59:59.000Z

15

Quantifying transient states in materials with the dynamic transmission electron microscope  

Science Journals Connector (OSTI)

......Engineering and Materials Science and Department...interest to the materials scientist. It has...Computer-controlled, active-feedback pointing...at the microscope cathode. The cathode is...specimen and the cathode laser fires at a...comparison to models of materials evolution. Image......

Geoffrey H. Campbell; Thomas LaGrange; Judy S. Kim; Bryan W. Reed; Nigel D. Browning

2010-08-01T23:59:59.000Z

16

Transmission-mode imaging in the environmental scanning electron microscope (ESEM)  

E-Print Network [OSTI]

sources function by heating a material until it starts to emit electrons (by increasing the energy of free electrons to above the Fermi surface of the material) and field-emission sources function by applying an electric field strong enough that electrons... obtained from studying E. coli, C. necator, and S. Typhimurium (Chapter 8) have been accepted for publication in Scanning, titled “The application of STEM and in-situ controlled dehydration to bac- terial systems using ESEM”. i Acknowledgements This project...

Staniewicz, Lech Thomas Leif

2012-02-07T23:59:59.000Z

17

Electron Microscope Facility  

ScienceCinema (OSTI)

Brookhaven Lab is home to one of only a few Scanning Transmision Electron Microscope (STEM) machines in the world and one of the few that can image single heavy atoms.

None

2010-01-08T23:59:59.000Z

18

Improvement of windowed type environmental-cell transmission electron microscope for in situ observation of gas-solid interactions  

SciTech Connect (OSTI)

We have developed an improved, windowed type environmental-cell (E-cell) transmission electron microscope (TEM) for in situ observation of gas-solid interactions, such as catalytic reactions at atmospheric pressure. Our E-cell TEM includes a compact E-cell specimen holder with mechanical stability, resulting in smoother introduction of the desired gases compared with previous E-cell TEMs. In addition, the gas control unit was simplified by omitting the pressure control function of the TEM pre-evacuation chamber. This simplification was due to the successful development of remarkably tough thin carbon films as the window material. These films, with a thickness of <10 nm, were found to withstand pressure differences >2 atm. Appropriate arrangement of the specimen position inside the E-cell provided quantitatively analyzable TEM images, with no disturbances caused by the windowed films. As an application, we used this E-cell TEM to observe the dynamic shape change in a catalytic gold nanoparticle supported on TiO{sub 2} during the oxidation of CO gas.

Kawasaki, Tadahiro [Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa, Nagoya 464-8603 (Japan); PRESTO-JST, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012 (Japan); Ueda, Kouta [Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa, Nagoya 464-8603 (Japan); Ichihashi, Mikio; Tanji, Takayoshi [EcoTopia Science Institute, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

2009-11-15T23:59:59.000Z

19

In situ redox cycle of a nickelYSZ fuel cell anode in an environmental transmission electron microscope  

E-Print Network [OSTI]

of a nickel/yttria-stabilized zirconia solid oxide fuel cell anode. The results reveal that the transfer transmission electron microscopy (ETEM); Solid oxide fuel cell (SOFC); Reduction; Oxidation; Density functional theory (DFT) 1. Introduction Solid oxide fuel cell (SOFC) technology is a promising energy conversion

Dunin-Borkowski, Rafal E.

20

High resolution electron microscopic studies on ferrosilite III  

Science Journals Connector (OSTI)

High resolution transmission electron microscopic (HRTEM) studies on ferrosilite (Fs) III confirmed the periodicity nine (p=9) of the tetrahedral chains in this silicate. Various chain periodicit...

M. Czank; B. Simons

1983-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

A way to higher resolution: spherical-aberration correction in a 200 kV transmission electron microscope  

Science Journals Connector (OSTI)

......micrographs, ultramicroscopy 15: 151-172. rical pole-piece dimensions. The 200 kV spherical-aberra- 8 Thust A, Overwijk M H F, coene w M J. and Lentzen M (1996) tion-COrreCted microscope avoids the radiation damage Numerical correction of......

Knut Urban; Bernd Kabius; Max Haider; Harald Rose

1999-01-01T23:59:59.000Z

22

Electron microscope studies  

SciTech Connect (OSTI)

This year our laboratory has continued to make progress in the design of electron-optical systems, in the study of structure-function relationships of large multi-subunit proteins, in the development of new image processing software and in achieving a workable sub-angstrom STEM. We present an algebraic approach to the symmetrical Einzel (unipotential) lens wherein we simplify the analysis by specifying a field shape that meets some preferred set of boundary or other conditions and then calculate the fields. In a second study we generalize this approach to study of three element electrostatic lenses of which the symmetrical Einzel lens is a particular form. The purpose is to develop a method for assisting in the design of a lens for a particular purpose. In our biological work we study a stable and functional dodecameric complex of globin chains from the hemoglobin of Lumbricus terrestris. This is a complex lacking the linker'' subunit first imaged in this lab and required for maintenance of the native structure. In addition, we do a complete work-up on the hemoglobin of the marine polychaete Eudistylia vancouverii demonstrating the presence of a hierarchy of globin complexes. We demonstrate stable field-emission in the sub-angstrom STEM and the preliminary alignment of the beam. We continue our exploration of a algorithms for alignment of sequences of protein and DNA. Our computer facilities now include four second generation RISC workstations and we continue to take increasing advantage of the floating-point and graphical performance of these devices.

Crewe, A.V.; Kapp, O.H.

1991-06-01T23:59:59.000Z

23

Dynamic Transmission Electron Microscopy  

SciTech Connect (OSTI)

Dynamic transmission electron microscopy (DTEM) combines the benefits of high spatial resolution electron microscopy with the high temporal resolution of ultrafast lasers. The incorporation of these two components into a single instrument provides a perfect platform for in situ observations of material processes. However, previous DTEM applications have focused on observing structural changes occurring in samples exposed to high vacuum. Therefore, in order to expand the pump-probe experimental regime to more natural environmental conditions, in situ gas and liquid chambers must be coupled with Dynamic TEM. This chapter describes the current and future applications of in situ liquid DTEM to permit time-resolved atomic scale observations in an aqueous environment, Although this chapter focuses mostly on in situ liquid imaging, the same research potential exists for in situ gas experiments and the successful integration of these techniques promises new insights for understanding nanoparticle, catalyst and biological protein dynamics with unprecedented spatiotemporal resolution.

Evans, James E.; Jungjohann, K. L.; Browning, Nigel D.

2012-10-12T23:59:59.000Z

24

Mapping the Valence States of Transition-Metal Elements Using Energy-Filtered Transmission Electron Microscopy  

E-Print Network [OSTI]

spectrum of MnO2 acquired at 200 kV using a Hitachi HF-2000 transmission electron microscope equipped lines observed in electron energy-loss spectroscopy in a transmission electron microscope (TEMMapping the Valence States of Transition-Metal Elements Using Energy-Filtered Transmission Electron

Wang, Zhong L.

25

Attainable Resolution of Energy-Selecting Image Using High-Voltage Electron Microscope  

Science Journals Connector (OSTI)

......mapping using an imaging energy filter: Image formation...elemental mapping In an energy filtering transmission...Egerton RF: Electron energy-loss spectroscopy In the electron microscope. New York and London: Plenum Press......

Hiroki Kurata; Sakumi Moriguchi; Seiji Isoda; Takashi Kobayashi

1996-02-01T23:59:59.000Z

26

NCEM National Center for Electron Microscopy: Microscopes and Facilities:  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

0.5 0.5 The TEAM 0.5 microscope is a double-aberration-corrected (scanning) transmission electron microscope (STEM/TEM) capable of producing images with 50 pm resolution. The basic instrument is a modified FEI Titan 80-300 microscope equipped with a special high-brightness Schottky-field emission electron source, a gun monochromator, a high-resolution GIF Tridiem energy-filter, and two CEOS hexapole-type spherical aberration correctors. The illumination aberration corrector corrects coherent axial aberrations up to 4th order, as well as 5th order spherical aberration and six-fold astigmatism. The imaging aberration corrector fully corrects for coherent axial aberrations up to 3rd order and partially compensates for 4th and 5th order aberrations. The microscope has two 2048x2048 slow-scan CCD

27

Directly correlated transmission electron microscopy and atom...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Directly correlated transmission electron microscopy and atom probe tomography of grain boundary oxidation in a Ni-Al binary Directly correlated transmission electron microscopy...

28

High-energy-resolution monochromator for aberration-corrected scanning transmission electron microscopy/electron energy-loss spectroscopy  

Science Journals Connector (OSTI)

...R. F. 1996 Electron energy-loss spectroscopy in...microscope, 2nd edn. New York, NYPlenum. Egerton...Transmission electron energy loss spectrometry in materials...energy-gain spectroscopy. New J. Phys. 10, 1367-2630...

2009-01-01T23:59:59.000Z

29

Cryo-Transmission Electron Microscope (TEM) | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

film consisting of glucose oxidasePtfunctional graphene sheetschitosan (GODPtFGSchitosan) for glucose sensing was... Multiplexed Electrochemical Immunoassay of...

30

The early history of the scanning electron microscope  

Science Journals Connector (OSTI)

The article begins with an account of prewar German work particularly that of von Ardenne who established the theoretical basis of a scanning electron microscope and constructed an instrument which was primarily intended to overcome chromatic aberration when relatively thick specimens were examined by transmission. Neither this microscope nor a different one built a few years later in the U. S. A. attained sufficient resolution to gain acceptance and the reasons for this are examined. The remainder of the article deals with work carried out in the Cambridge University Engineering Department over the years from 1948 to about 1965 when the first successful commercial instrument was produced. The contributions made by successive research students are explained as are also the nonscientific factors which influenced the course of the development.

C. W. Oatley

1982-01-01T23:59:59.000Z

31

Integrated windows-based control system for an electron microscope  

SciTech Connect (OSTI)

A Windows application has been developed for management and operation of beam instruments such as electron or ion microscopes. It provides a facility that allows an operator to manage a complicated instrument with minimal effort, primarily under mouse control. The hardware control components used on similar instruments (e.g., the scanning transmission electron microscopes in our lab), such as toggles, buttons, and potentiometers for adjustments on various scales, are all replaced by the controls of the Windows application and are addressable on a single screen. The new controls in this program (via adjustable software settings) offer speed of response and smooth operation providing tailored control of various instrument parameters. Along with the controls offering single parameter adjustment, a two-dimensional control was developed that allows two parameters to be coupled and addressed simultaneously. This capability provides convenience for such tasks as finding the beam'' and directing it to a location of interest on the specimen. Using an icon-based display, this Windows application provides better integrated and more robust information for monitoring instrument status than the indicators and meters of the traditional instrument controls. As a Windows application, this program is naturally able to share the resources of the Windows system and is thus able to link to many other applications such as our image acquisition and processing programs. Computer control provides automatic protection and instant diagnostics for the experimental instrument. This Windows application is fully functional and is in daily use to control a new type of electron microscope developed in our lab.

Ruan, S. (The Enrico Fermi Institute, The University of Chicago, Chicago, Illinois 60637 (United States)); Kapp, O.H. (The Department of Radiology and The Enrico Fermi Institute, The University of Chicago, Chicago, Illinois 60637 (United States))

1994-12-01T23:59:59.000Z

32

Iran Thomas Auditorium, 8600 Environmental Transmission Electron...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

April 26, 2012 11:00 am Iran Thomas Auditorium, 8600 Environmental Transmission Electron Microscopy for Catalysis Research: The Example of Carbon Nanotubes Eric A. Stach Center for...

33

Simultaneous STM and UHV electron microscope observation of silicon nanowires extracted from Si(111) surface  

Science Journals Connector (OSTI)

......research-article Articles Simultaneous STM and UHV electron microscope observation of silicon...silicon|tungsten| Simultaneous STM and UHV electron microscope observation of silicon...Semiconductor Special Issue Simultaneous STM and UHV electron microscope observation of silicon......

Y. Naitoh; K. Takayanagi; Y. Oshima; H. Hirayama

2000-01-01T23:59:59.000Z

34

In-situ Transmission Electron Microscopy and Spectroscopy Studies...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission Electron Microscopy and Spectroscopy Studies of Interfaces in Li-ion Batteries: Challenges and In-situ Transmission Electron Microscopy and Spectroscopy Studies of...

35

Human Prostatic Carcinoma: An Electron Microscope Study  

Science Journals Connector (OSTI)

...knives on a Porter-Blum micro tome. The ultrathin...believe that these droplets arc of heterogeneous nature...15. - ". Fatty Acid Oxidation in Normal and Neoplastic...Sectioning in Electron Micros copy. Stain Technol...Sections for Electron Micros copy. J. Biophys...

Peter Mao; Komei Nakao; and Alfred Angrist

1966-05-01T23:59:59.000Z

36

Vibration Proof Construction of 1000kV Electron Microscope  

Science Journals Connector (OSTI)

......University Press 1970 other ORIGINAL Vibration Proof Construction of 1000kV Electron...with the center of gravity. That is, a vibration proof hanging console was made as a method...protecting a 1000kV Electron Microscope from vibration, and this allowed the whole instrument......

Yoshio SAKITANI; Susumu OZASA

1970-01-01T23:59:59.000Z

37

Nanomanipulation of biological samples using a compact atomic force microscope under scanning electron microscope observation  

Science Journals Connector (OSTI)

......Leakage of the EB current to the micro-electric circuit of the piezo-resistive sensor...Science and Technology, Development of elementary techniques for electron microscope in...Superfine R, Washburn S. In situ resistance measurements of strained carbon nanotubes......

Futoshi Iwata; Yuya Mizuguchi; Hideyuki Ko; Tatsuo Ushiki

2011-12-01T23:59:59.000Z

38

In-Situ Electrochemical Transmission Electron Microscopy for Battery Research  

SciTech Connect (OSTI)

The recent development of in-situ liquid stages for (scanning) transmission electron microscopes now makes it possible for us to study the details of electrochemical processes under operando conditions. As electrochemical processes are complex, care must be taken to calibrate the system before any in-situ/operando observations. In addition, as the electron beam can cause effects that look similar to electrochemical processes at the electrolyte/electrode interface, an understanding of the role of the electron beam in modifying the operando observations must also be understood. In this paper we describe the design, assembly, and operation of an in-situ electrochemical cell, paying particular attention to the method for controlling and quantifying the experimental parameters. The use of this system is then demonstrated for the lithiation/delithiation of silicon nanowires.

Mehdi, Beata L [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Gu, Meng [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Parent, Lucas [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Xu, WU [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Nasybulin, Eduard [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Chen, Xilin [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Unocic, Raymond R [ORNL] [ORNL; Xu, Pinghong [University of California, Davis] [University of California, Davis; Welch, David [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Abellan, Patricia [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Zhang, Ji-Guang [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Liu, Jun [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Wang, Chongmin [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Arslan, Ilke [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Evans, James E [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL); Browning, Nigel [Pacific Northwest National Laboratory (PNNL)] [Pacific Northwest National Laboratory (PNNL)

2014-01-01T23:59:59.000Z

39

Measurement of Semiconductor Surface Potential using the Scanning Electron Microscope  

SciTech Connect (OSTI)

We calibrate the secondary electron signal from a standard scanning electron microscope to voltage, yielding an image of the surface or near-surface potential. Data on both atomically abrupt heterojunction GaInP/GaAs and diffused homojunction Si solar cell devices clearly show the expected variation in potential with position and applied bias, giving depletion widths and locating metallurgical junctions to an accuracy better than 10 nm. In some images, distortion near the p-n junction is observed, seemingly consistent with the effects of lateral electric fields (patch fields). Reducing the tube bias removes this distortion. This approach results in rapid and straightforward collection of near-surface potential data using a standard scanning electron microscope.

Heath, J. T.; Jiang, C. S.; Al-Jassim, M. M.

2012-02-15T23:59:59.000Z

40

E-Print Network 3.0 - analytical electron microscope Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

two-contact electrical biasing specimen holder for electron holography and electron tomography of semiconductor devices Summary: in an electron microscope", which allows high...

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

NCEM National Center for Electron Microscopy: Microscopes and Facilities:  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AEM AEM AEME The Analytical Electron Microscope is optimized for elemental microanalysis. The basic instrument is a JEOL 200CX microscope with a side-entry double-tilt goniometer stage and an assortment of specimen holders. This machine can be operated at between 80 and 200 kV in the TEM or STEM mode. Electron energy loss and x-ray signals for elemental microanalysis or spectral imaging can be collected either separately or simultaneously using probe diameters from 6nm to 100nm. Diffraction modes include convergent beam diffraction for three-dimensional structure information and micro-diffraction with a minimum probe size of 20nm. For updates or details, contact Zonghoon Lee or Velimir Radmilovic. The instrument is equipped with two Kevex EDXS detectors and a Gatan PEELS

42

TRANSMISSION ELECTRON MICROSCOPY OF WEAKLY DEFORMED ALKALI HALIDE CRYSTALS  

E-Print Network [OSTI]

377 TRANSMISSION ELECTRON MICROSCOPY OF WEAKLY DEFORMED ALKALI HALIDE CRYSTALS H. STRUNK Max'importance croissante du durcissement de la solution solide. Abstract. 2014 Transmission electron microscopy (TEM Abstracts 7j66 - 7 I' 1. Introduction. - It is only some years ago that transmission electron microscopy

Boyer, Edmond

43

NCEM National Center for Electron Microscopy: Microscopes and Facilities:  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

LIBRA LIBRA The 200kV Zeiss monochromated LIBRA 200MC is designed to produce high contrast imaging for TEM and STEM and either convergent beam or parallel beam diffraction using Koehler illumination.In addition, the incorporation of a monochromator into the field emission gun enables energy resolution of ~0.15eV for electron energy loss spectroscopy. The dedicated in-column Omega Filter implemented in this microscope also can be used for both spectroscopic analysis and energy-filtered imaging with a 2048x2048 CCD camera. The high tilt capability of the stage and pole piece accepts various types of analytical holders.This microscope is optimized for soft materials applications that require either the high contrast imaging performance or analytical methods such as EF-TEM and STEM.( Instrument

44

Nonlinear transmission line based electron beam driver  

SciTech Connect (OSTI)

Gated field emission cathodes can provide short electron pulses without the requirement of laser systems or cathode heating required by photoemission or thermionic cathodes. The large electric field requirement for field emission to take place can be achieved by using a high aspect ratio cathode with a large field enhancement factor which reduces the voltage requirement for emission. In this paper, a cathode gate driver based on the output pulse train from a nonlinear transmission line is experimentally demonstrated. The application of the pulse train to a tufted carbon fiber field emission cathode generates short electron pulses. The pulses are approximately 2 ns in duration with emission currents of several mA, and the train contains up to 6 pulses at a frequency of 100 MHz. Particle-in-cell simulation is used to predict the characteristic of the current pulse train generated from a single carbon fiber field emission cathode using the same technique.

French, David M.; Hoff, Brad W.; Tang Wilkin; Heidger, Susan; Shiffler, Don [Directed Energy Directorate, Air Force Research Laboratory, Kirtland AFB, New Mexico 87117 (United States); Allen-Flowers, Jordan [Program in Applied Mathematics, University of Arizona, Tucson, Arizona 85721 (United States)

2012-12-15T23:59:59.000Z

45

In situ laser processing in a scanning electron microscope  

SciTech Connect (OSTI)

Laser delivery probes using multimode fiber optic delivery and bulk focusing optics have been constructed and used for performing materials processing experiments within scanning electron microscope/focused ion beam instruments. Controlling the current driving a 915-nm semiconductor diode laser module enables continuous or pulsed operation down to sub-microsecond durations, and with spot sizes on the order of 50 {micro}m diameter, achieving irradiances at a sample surface exceeding 1 MW/cm{sup 2}. Localized laser heating has been used to demonstrate laser chemical vapor deposition of Pt, surface melting of silicon, enhanced purity, and resistivity via laser annealing of Au deposits formed by electron beam induced deposition, and in situ secondary electron imaging of laser induced dewetting of Au metal films on SiO{sub x}.

Roberts, Nicholas [University of Tennessee, Knoxville (UTK); Fowlkes, Jason Davidson [ORNL; Rack, Prof. Philip [University of Tennessee, Knoxville (UTK); Moore, Tom [OmniProbe, Inc.; Magel, Greg [OmniProbe, Inc.; Hartfield, Cheryl [OmniProbe, Inc.

2012-01-01T23:59:59.000Z

46

In situ laser processing in a scanning electron microscope  

SciTech Connect (OSTI)

Laser delivery probes using multimode fiber optic delivery and bulk focusing optics have been constructed and used for performing materials processing experiments within scanning electron microscope/focused ion beam instruments. Controlling the current driving a 915-nm semiconductor diode laser module enables continuous or pulsed operation down to sub-microsecond durations, and with spot sizes on the order of 50 {mu}m diameter, achieving irradiances at a sample surface exceeding 1 MW/cm{sup 2}. Localized laser heating has been used to demonstrate laser chemical vapor deposition of Pt, surface melting of silicon, enhanced purity, and resistivity via laser annealing of Au deposits formed by electron beam induced deposition, and in situ secondary electron imaging of laser induced dewetting of Au metal films on SiO{sub x}.

Roberts, Nicholas A.; Magel, Gregory A.; Hartfield, Cheryl D.; Moore, Thomas M.; Fowlkes, Jason D.; Rack, Philip D. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, Tennessee 37996 (United States) and Omniprobe, Inc., an Oxford Instruments Company, 10410 Miller Rd., Dallas, Texas 75238 (United States); Omniprobe, Inc., an Oxford Instruments Company, 10410 Miller Rd., Dallas, Texas 75238 (United States); Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Department of Materials Science and Engineering, University of Tennessee, Knoxville, Tennessee 37996 (United States) and Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

2012-07-15T23:59:59.000Z

47

Miniature self-contained vacuum compatible electronic imaging microscope  

DOE Patents [OSTI]

A vacuum compatible CCD-based microscopic camera with an integrated illuminator. The camera can provide video or still feed from the microscope contained within a vacuum chamber. Activation of an optional integral illuminator can provide light to illuminate the microscope subject. The microscope camera comprises a housing with a objective port, modified objective, beam-splitter, CCD camera, and LED illuminator.

Naulleau, Patrick P. (Oakland, CA); Batson, Phillip J. (Alameda, CA); Denham, Paul E. (Crockett, CA); Jones, Michael S. (San Francisco, CA)

2001-01-01T23:59:59.000Z

48

New Developments in Transmission Electron Microscopy for Nanotechnology**  

E-Print Network [OSTI]

New Developments in Transmission Electron Microscopy for Nanotechnology** By Zhong Lin Wang* 1. Electron Microscopy and Nanotechnology Nanotechnology, as an international initiative for science manufacturing are the foundation of nanotechnology. Tracking the historical background of why nanotechnology

Wang, Zhong L.

49

NCEM National Center for Electron Microscopy: Microscopes and Facilities:  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Specimen Preparation Specimen Preparation Preparation of samples with large transparent areas and flat surfaces is a key element of electron microscopy. In particular, the interpretation of lattice or holographic images is often limited by the sample's geometry and surface roughness. These parameters are largely determined by a particular sample preparation procedure. The increasing demand for microscopes with a spatial resolution of better than 1Ã… increases the need for improved sample preparation techniques. A substantial effort at NCEM is devoted to the development of reliable and specialized thinning techniques. Current programs explore the application of chemicals to shape the surfaces of thin films, the use of nanospheres for observation of small particles, and the

50

Low-energy electron microscope of novel design  

Science Journals Connector (OSTI)

We describe the design of an electron emission microscope capable of imaging a sample surface with low-energy electrons reflected from it or with UV photoelectrons. In the primary beam column provision is made to compensate the energy dispersion of the beam-separating magnet and to be able to choose different primary and secondary beam energies for Auger analysis. The secondary beam column comprises a spherical condenser sector field as energy filter. In order to avoid image aberrations caused by the two sector fields, linked imaging is provided so that intermediate surface images are formed in the deflection centers of the sector fields, while the energy selection is done at pupil positions. The emission lens is an electrostatic tetrode. The electrodes are shaped so as to accommodate an optical Schwarzschild-type mirror objective for visual in-situ observation or UV irradiation of the sample surface. A lateral resolution of about 10 nm is expected with UV photoemission microscopy and somewhat better with reflected electron microscopy.

H. Liebl; B. Senftinger

1991-01-01T23:59:59.000Z

51

Gas mixing system for imaging of nanomaterials under dynamic environments by environmental transmission electron microscopy  

SciTech Connect (OSTI)

A gas mixing manifold system that is capable of delivering a stable pressure stream of a desired composition of gases into an environmental transmission electron microscope has been developed. The system is designed to provide a stable imaging environment upon changes of either the composition of the gas mixture or upon switching from one gas to another. The design of the system is described and the response of the pressure inside the microscope, the sample temperature, and sample drift in response to flow and composition changes of the system are reported.

Akatay, M. Cem [School of Materials Engineering and Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907 (United States)] [School of Materials Engineering and Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907 (United States); Zvinevich, Yury; Ribeiro, Fabio H., E-mail: fabio@purdue.edu, E-mail: estach@bnl.gov [Forney Hall of Chemical Engineering, Purdue University, West Lafayette, Indiana 47907 (United States); Baumann, Philipp [Computer Sciences, University of Applied Sciences of Northeastern Switzerland, 4132 Muttenz, Switzerland and Department of Physics, Yeshiva University, New York, New York 10016 (United States)] [Computer Sciences, University of Applied Sciences of Northeastern Switzerland, 4132 Muttenz, Switzerland and Department of Physics, Yeshiva University, New York, New York 10016 (United States); Stach, Eric A., E-mail: fabio@purdue.edu, E-mail: estach@bnl.gov [Center for Functional Nanomaterials, Brookhaven National Laboratory, Upton, New York 11973 (United States)

2014-03-15T23:59:59.000Z

52

Imaging and microanalysis of thin ionomer layers by scanning transmission electron microscopy  

SciTech Connect (OSTI)

Improved conditions for imaging and spectroscopic mapping of thin perfluorosulfonic acid (PFSA) ionomer layers in fuel cell electrodes by scanning transmission electron microscopy (STEM) have been investigated. These conditions are first identified on model systems of Nafion ionomer-coated nanostructured thin films and nanoporous Si. The optimized conditions are then applied in a quantitative study of the ionomer through-layer loading for two typical electrode catalyst coatings using electron energy loss and energy dispersive X-ray spectroscopy in the transmission electron microscope. The e-beam induced damage to the perfluorosulfonic acid (PFSA) ionomer is quantified by following the fluorine mass loss with electron exposure and is then mitigated by a few orders of magnitude using cryogenic specimen cooling and a higher incident electron voltage. Multivariate statistical analysis is also applied to the analysis of spectrum images for data denoising and unbiased separation of independent components related to the catalyst, ionomer, and support.

Cullen, David A [ORNL; Koestner, Roland [General Motors Corporation; Kukreja, Ratan [General Motors Corporation; Minko, Sergiy [Clarkson University, Potsdam, NY; Trotsenko, Oleksandr [Clarkson University, Potsdam, NY; Tokarev, Alexander V [ORNL; Guetaz, Laure [French Atomic Energy Commission (CEA), Grenoble; Meyer III, Harry M [ORNL; Parish, Chad M [ORNL; More, Karren Leslie [ORNL

2014-01-01T23:59:59.000Z

53

Compact cryogenic Kerr microscope for time-resolved studies of electron spin transport in microstructures  

E-Print Network [OSTI]

Compact cryogenic Kerr microscope for time-resolved studies of electron spin transport A compact cryogenic Kerr microscope for operation in the small volume of high-field magnets is described-temperature optical microscope, elec- tromagnet and cryogenic cell with cold finger to measure continuous-wave cw

van der Wal, Caspar H.

54

Fast Image Drift Compensation in Scanning Electron Microscope Using Image Registration  

E-Print Network [OSTI]

Fast Image Drift Compensation in Scanning Electron Microscope Using Image Registration Naresh Marturi, Sounkalo Demb´el´e and Nadine Piat Abstract-- Scanning Electron Microscope (SEM) image ac analysis and characterization of materials to recover their structural, mechanical, electrical and optical

Boyer, Edmond

55

Preparation of Micro-grid for the Electron Microscopic Observation with High Magnification  

Science Journals Connector (OSTI)

......1958 letter LETTER Preparation of Micro-grid for the Electron Microscopic Observation...Japan L E T T E R Preparation of Micro-grid for the Electron Microscopic Observation...call this collodion net-work a micro-grid. Procedure of preparation (1......

S. Sakata

1958-01-01T23:59:59.000Z

56

Research and Design of a Sample Heater for Beam Line 6-2c Transmission X-ray Microscope  

SciTech Connect (OSTI)

There exists a need for environmental control of samples to be imaged by the Transmission X-Ray Microscope (TXM) at the SSRLs Beam Line 6-2c. In order to observe heat-driven chemical or morphological changes that normally occur in situ, microscopes require an additional component that effectively heats a given sample without heating any of the microscope elements. The confinement of the heat and other concerns about the heaters integrity limit which type of heater is appropriate for the TXM. The bulk of this research project entails researching different heating methods used previously in microscopes, but also in other industrial applications, with the goal of determining the best-fitting method, and finally in designing a preliminary sample heater.

Policht, Veronica; /Loyola U., Chicago /SLAC

2012-08-27T23:59:59.000Z

57

Four generations of high-voltage electron microscopes  

Science Journals Connector (OSTI)

......microscopes 307 Table 3 Edge lengths of elementary cubes. a0, and separations...data were obtained by electrical resistance measurements [41,42], those...measure- ment of the residual electric resistance using 'conven- tional' accelerator......

Alfred Seeger

1999-01-01T23:59:59.000Z

58

2013 R&D 100 Award: Movie-mode electron microscope captures nanoscale  

ScienceCinema (OSTI)

A new instrument developed by LLNL scientists and engineers, the Movie Mode Dynamic Transmission Electron Microscope (MM-DTEM), captures billionth-of-a-meter-scale images with frame rates more than 100,000 times faster than those of conventional techniques. The work was done in collaboration with a Pleasanton-based company, Integrated Dynamic Electron Solutions (IDES) Inc. Using this revolutionary imaging technique, a range of fundamental and technologically important material and biological processes can be captured in action, in complete billionth-of-a-meter detail, for the first time. The primary application of MM-DTEM is the direct observation of fast processes, including microstructural changes, phase transformations and chemical reactions, that shape real-world performance of nanostructured materials and potentially biological entities. The instrument could prove especially valuable in the direct observation of macromolecular interactions, such as protein-protein binding and host-pathogen interactions. While an earlier version of the technology, Single Shot-DTEM, could capture a single snapshot of a rapid process, MM-DTEM captures a multiframe movie that reveals complex sequences of events in detail. It is the only existing technology that can capture multiple electron microscopy images in the span of a single microsecond.

Lagrange, Thomas; Reed, Bryan

2014-07-21T23:59:59.000Z

59

2013 R&D 100 Award: Movie-mode electron microscope captures nanoscale  

SciTech Connect (OSTI)

A new instrument developed by LLNL scientists and engineers, the Movie Mode Dynamic Transmission Electron Microscope (MM-DTEM), captures billionth-of-a-meter-scale images with frame rates more than 100,000 times faster than those of conventional techniques. The work was done in collaboration with a Pleasanton-based company, Integrated Dynamic Electron Solutions (IDES) Inc. Using this revolutionary imaging technique, a range of fundamental and technologically important material and biological processes can be captured in action, in complete billionth-of-a-meter detail, for the first time. The primary application of MM-DTEM is the direct observation of fast processes, including microstructural changes, phase transformations and chemical reactions, that shape real-world performance of nanostructured materials and potentially biological entities. The instrument could prove especially valuable in the direct observation of macromolecular interactions, such as protein-protein binding and host-pathogen interactions. While an earlier version of the technology, Single Shot-DTEM, could capture a single snapshot of a rapid process, MM-DTEM captures a multiframe movie that reveals complex sequences of events in detail. It is the only existing technology that can capture multiple electron microscopy images in the span of a single microsecond.

Lagrange, Thomas; Reed, Bryan

2014-04-03T23:59:59.000Z

60

Optical design of electron microscope lenses and energy filters  

Science Journals Connector (OSTI)

......Two-stage elearon energy analyzer Czech Republic...Academic Press New York) piece for a transmission...Academic Press, New York). 47 Tang T T...T.!.!.2 : Energy-filtering Transmission...Proposal of a new energy filter for TEM......

K Tsuno

1999-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

A Transmission Electron Microscopy Study of Presolar Hibonite  

Science Journals Connector (OSTI)

We report isotopic and microstructural data on five presolar hibonite grains (KH1, KH2, KH6, KH15, and KH21) identified in an acid residue of the Krymka LL3.1 ordinary chondrite. Isotopic measurements by secondary ion mass spectrometry (SIMS) verified a presolar circumstellar origin for the grains. Transmission electron microscopy (TEM) examination of the crystal structure and chemistry of the grains was enabled by in situ sectioning and lift-out with a focused-ion-beam scanning-electron microscope (FIB-SEM). Comparisons of isotopic compositions with models indicate that four of the five grains formed in low-mass stars that evolved through the red giant/asymptotic giant branches (RGBs/AGBs), whereas one grain formed in the ejecta of a Type II supernova. Selected-area electron-diffraction patterns show that all grains are single crystals of hibonite. Some grains contain minor structural perturbations (stacking faults) and small spreads in orientation that can be attributed to a combination of growth defects and mechanical processing by grain-grain collisions. The similar structure of the supernova grain to those from RGB/AGB stars indicates a similarity in the formation conditions. Radiation damage (e.g., point defects), if present, occurs below our detection limit. Of the five grains we studied, only one has the pure hibonite composition of CaAl12O19. All others contain minor amounts of Mg, Si, Ti, and Fe. The microstructural data are generally consistent with theoretical predictions, which constrain the circumstellar condensation temperature to a range of 1480-1743 K, assuming a corresponding total gas pressure between 1 ? 10–6 and 1 ? 10–3 atm. The TEM data were also used to develop a calibration for SIMS determination of Ti contents in oxide grains. Grains with extreme 18O depletions, indicating deep mixing has occurred in their parent AGB stars, are slightly Ti enriched compared with grains from stars without deep mixing, most likely reflecting differences in grain condensation conditions.

Thomas J. Zega; Conel M. O'D. Alexander; Larry R. Nittler; Rhonda M. Stroud

2011-01-01T23:59:59.000Z

62

Scanning Transmission Electron Microscopy Investigations of Complex Oxides  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Scanning Transmission Electron Microscopy Investigations of Complex Oxides Scanning Transmission Electron Microscopy Investigations of Complex Oxides Monday, May 23, 2011 - 3:30pm SSRL Conference room 137-322 Professor Tom Vogt, NanoCenter & Department of Chemistry, University of South Carolina High-Angle-Annular-Dark-Field/Scanning Transmission Electron Microscopy (HAADF/STEM) is a technique uniquely suited for detailed studies of the structure and composition of complex oxides. The HAADF detector collects electrons which have interact inelastically with the potentials of the atoms in the specimen and therefore resembles the better known Z2 (Z is atomic number) Rutherford scattering. One class of important catalysts consists of bronzes based on pentagonal {Mo6O21} building units; these include Mo5O14 and Mo17O47. In the last 20 years, new materials doped with

63

ELECTRON MICROSCOPE STUDIES OF THE MECHANISM OF NUCLEATION AND GROWTH OF Cu Au II FROM THE DISORDERED STATE  

E-Print Network [OSTI]

846. ELECTRON MICROSCOPE STUDIES OF THE MECHANISM OF NUCLEATION AND GROWTH OF Cu Au II FROM the electron microscope. The alloy is disordered by annealing at 450 °C, and the nucleation and growth with the electron microscope by Ogawa and al. [1], and subsequently by Pashley and co-workers [2], [3], [4

Boyer, Edmond

64

Power electronics in electric utilities: HVDC power transmission systems  

SciTech Connect (OSTI)

High Voltage Direct Current (HVDC) power transmission systems constitute an important application of power electronics technology. This paper reviews salient aspects of this growing industry. The paper summarizes the history of HVDC transmission and discusses the economic and technical reasons responsible for development of HVDC systems. The paper also describes terminal design and basic configurations of HVDC systems, as well as major equipments of HVDC transmission system. In this regard, the state-of-the-art technology in the equipments constructions are discussed. Finally, the paper reviews future developments in the HVDC transmission systems, including promising technologies, such as multiterminal configurations, Gate Turn-Off (GTO) devices, forced commutation converters, and new advances in control electronics.

Nozari, F.; Patel, H.S.

1988-04-01T23:59:59.000Z

65

Nanoprobe cathodoluminescence scanning electron microscope as applied to synthesized diamond  

Science Journals Connector (OSTI)

......attention to applications in active and passive electronics...electron gun of thermionic cathode. Since the light emitted...FESEM are: (i) the cathode is operated at room temperature...light emission from the cathode; and (ii) an electron...photon counting system. materials emitting weak CL so long......

Hiroshi Matsuo; Shogo Awata; Yoshihide Kimura; Ryuichi Shimizu

1999-01-01T23:59:59.000Z

66

NCEM National Center for Electron Microscopy: Microscopes and Facilities:  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

CM 200 FEG CM 200 FEG AEME The Philips CM200/FEG is a versatile instrument that is designed for analysis of the physical, chemical and magnetic microstructure at high spatial resolution. In addition to high resolution imaging capability, the machine is optimized for analytical electron microscopy and Lorentz imaging, under normal as well as dynamic conditions of variable temperature (77K - 1250K) and applied magnetic fields. Spatially resolved compositional analysis by X-ray emission spectroscopy (Z > 5), local electronic structure measurements by electron energy-loss spectroscopy (Z > 2), convergent beam electron diffraction for three-dimensional structure information, and energy-filtered imaging at the nanometer scale are some of the techniques available on this instrument. In addition, a TEM differential phase

67

NCEM National Center for Electron Microscopy: Microscopes and Facilities:  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

SPLEEM SPLEEM Publications Imaging Spin Reorientation Transitions in Consecutive Atomic Co layers, Farid El Gabaly, Silvia Gallego, M. Carmen Munoz, Laszlo Szunyogh, Peter Weinberger, Kevin F. McCarty, Christof Klein, Andreas K. Schmid, Juan de la Figuera, submitted Direct imaging of spin-reorientation transitions in ultra-thin Ni films by spin-polarized low-energy electron microscopy, C. Klein, A. K. Schmid, R. Ramchal, and M. Farle, submitted Controlling the kinetic order of spin-reorientation transitions in Ni/Cu(100) films by tuning the substrate step-structure, C. Klein, R. Ramchal, A.K. Schmid, M. Farle, submitted Self-organization and magnetic domain microstructure of Fe nanowire arrays, N. Rougemaille and A.K. Schmid, submitted Self-Assembled Nanofold Network Formation on Layered Crystal Surfaces

68

A new Scanning Transmission X-ray Microscope at the ALS for operation up to 2500eV  

SciTech Connect (OSTI)

We report on the design and construction of a higher energy Scanning Transmission X-ray Microscope on a new bend magnet beam line at the Advanced Light Source. Previously we have operated such an instrument on a bend magnet for C, N and O 1s NEXAFS spectroscopy. The new instrument will have similar performance at higher energies up to and including the S 1s edge at 2472eV. A new microscope configuration is planned. A more open geometry will allow a fluorescence detector to count emitted photons from the front surface of the sample. There will be a capability for zone plate scanning in addition to the more conventional sample scanning mode. This will add the capability for imaging a massive sample at high resolution over a limited field of view, so that heavy reaction cells may be used to study processes in-situ, exploiting the longer photon attenuation length and the longer zone plate working distances available at higher photon energy. The energy range will extend down to include the C1s edge at 300eV, to allow high energy NEXAFS microscopic studies to correlate with the imaging of organics in the same sample region of interest.

Kilcoyne, David; Ade, Harald; Attwood, David; Hitchcock, Adam; McKean, Pat; Mitchell, Gary; Monteiro, Paulo; Tyliszczak, Tolek; Warwick, Tony

2010-01-31T23:59:59.000Z

69

materials analysis of inorganic, organic, and bioma-terials. See ELECTRON MICROSCOPE.  

E-Print Network [OSTI]

28 Plaster materials analysis of inorganic, organic, and bioma- terials. See ELECTRON MICROSCOPE: The next chip-scale technology, Mater. Today, 9:20­27, 2006. Plaster A plastic mixture of solids and water plaster is also used in the industry to designate plaster of paris. Plaster is usually applied in one

Anderson, Peter M.

70

Development of a new 3 MV ultra-high voltage electron microscope at Osaka University  

Science Journals Connector (OSTI)

......shown in Fig. 3 and the main specifications are summarized in Table 1...CW-rircuits at 3MV Main specifications of 3MV electron microscope...stage XI38 stages (at 3MV) InsuLation gas : SFft (4 atoms) Illuminating...This helps to minimize thermal drift of the specimen during......

Akio Takaoka; Katsumi Ura; Hirotaro Mori; Teiji Katsuta; Isao Matsui; Soichiro Hayashi

1997-01-01T23:59:59.000Z

71

Atomic-Scale Imaging and Spectroscopy for In Situ Liquid Scanning Transmission Electron Microscopy  

SciTech Connect (OSTI)

Observation of growth, synthesis, dynamics and electrochemical reactions in the liquid state is an important yet largely unstudied aspect of nanotechnology. The only techniques that can potentially provide the insights necessary to advance our understanding of these mechanisms is simultaneous atomic-scale imaging and quantitative chemical analysis (through spectroscopy) under environmental conditions in the transmission electron microscope (TEM). In this study we describe the experimental and technical conditions necessary to obtain electron energy loss (EEL) spectra from a nanoparticle in colloidal suspension using aberration corrected scanning transmission electron microscopy (STEM) combined with the environmental liquid stage. At a fluid path length below 400 nm, atomic resolution images can be obtained and simultaneous compositional analysis can be achieved. We show that EEL spectroscopy can be used to quantify the total fluid path length around the nanoparticle, and demonstrate characteristic core-loss signals from the suspended nanoparticles can be resolved and analyzed to provide information on the local interfacial chemistry with the surrounding environment. The combined approach using aberration corrected STEM and EEL spectra with the in situ fluid stage demonstrates a plenary platform for detailed investigations of solution based catalysis and biological research.

Jungjohann, K. L.; Evans, James E.; Aguiar, Jeff; Arslan, Ilke; Browning, Nigel D.

2012-06-04T23:59:59.000Z

72

Three-Dimensional Aberration-Corrected Scanning Transmission Electron Microscopy for Biology  

SciTech Connect (OSTI)

Recent instrumental developments have enabled greatly improved resolution of scanning transmission electron microscopes (STEM) through aberration correction. An additional and previously unanticipated advantage of aberration correction is the greatly improved depth sensitivity that has led to the reconstruction of a three-dimensional (3D) image from a focal series. In this chapter the potential of aberration-corrected 3D STEM to provide major improvements in the imaging capabilities for biological samples will be discussed. This chapter contains a brief overview ofthe various high-resolution 3D imaging techniques, a historical perspective of the development of STEM, first estimates of the dose-limited axial and lateral resolution on biological samples and initial experiments on stained thin sections.

De Jonge, Niels [ORNL; Sougrat, Rachid [ORNL; Pennycook, Stephen J [ORNL; Peckys, Diana B [ORNL; Lupini, Andrew R [ORNL

2007-01-01T23:59:59.000Z

73

Interaction of electrons with light metal hydrides in the transmission electron microscope  

Science Journals Connector (OSTI)

......light elements are partially subject to this limitation. To achieve a high hydrogen capacity (see http://energy.gov/eere/fuelcells/hydrogen-storage and http://www.nedo.go.jp/activities/FF_00518.html ), the majority of currently......

Yongming Wang; Takenobu Wakasugi; Shigehito Isobe; Naoyuki Hashimoto; Somei Ohnuki

2014-10-01T23:59:59.000Z

74

Combined Scanning Transmission Electron Microscopy Tilt- and Focal Series  

SciTech Connect (OSTI)

In this study, a combined tilt- and focal series is proposed as a new recording scheme for high-angle annular dark-field scanning transmission electron microscopy (STEM) tomography. Three-dimensional (3D) data were acquired by mechanically tilting the specimen, and recording a through-focal series at each tilt direction. The sample was a whole-mount macrophage cell with embedded gold nanoparticles. The tilt focal algebraic reconstruction technique (TF-ART) is introduced as a new algorithm to reconstruct tomograms from such combined tilt- and focal series. The feasibility of TF-ART was demonstrated by 3D reconstruction of the experimental 3D data. The results were compared with a conventional STEM tilt series of a similar sample. The combined tilt- and focal series led to smaller missing wedge artifacts, and a higher axial resolution than obtained for the STEM tilt series, thus improving on one of the main issues of tilt series-based electron tomography.

Dahmen, Tim [German Research Center for Artificial Intelligence (DFKI), Germany] [German Research Center for Artificial Intelligence (DFKI), Germany; Baudoin, Jean-Pierre G [ORNL] [ORNL; Lupini, Andrew R [ORNL] [ORNL; Kubel, Christian [Karlsruhe Institute of Technology, Leopoldshafen, Germany] [Karlsruhe Institute of Technology, Leopoldshafen, Germany; Slusallek, Phillip [German Research Center for Artificial Intelligence (DFKI), Germany] [German Research Center for Artificial Intelligence (DFKI), Germany; De Jonge, Niels [ORNL] [ORNL

2014-01-01T23:59:59.000Z

75

Effectiveness of electron-cyclotron and transmission resonance heating in inductively coupled plasmas  

E-Print Network [OSTI]

Effectiveness of electron-cyclotron and transmission resonance heating in inductively coupled October 2005 The electron-cyclotron and transmission resonances in magnetically enhanced low-pressure one. It is shown that, for a high discharge frequency, the plasma resistance is greatly enhanced at electron-cyclotron

Economou, Demetre J.

76

A new approach to nuclear microscopy: The ion-electron emission microscope  

SciTech Connect (OSTI)

A new multidimensional high lateral resolution ion beam analysis technique, Ion-Electron Emission Microscopy or IEEM is described. Using MeV energy ions, IEEM is shown to be capable of Ion Beam Induced Charge Collection (IBICC) measurements in semiconductors. IEEM should also be capable of microscopically and multidimensionally mapping the surface and bulk composition of solids. As such, IIEM has nearly identical capabilities as traditional nuclear microprobe analysis, with the advantage that the ion beam does not have to be focused. The technique is based on determining the position where an individual ion enters the surface of the sample by projection secondary electron emission microscopy. The x-y origination point of a secondary electron, and hence the impact coordinates of the corresponding incident ion, is recorded with a position sensitive detector connected to a standard photoemission electron microscope (PEEM). These signals are then used to establish coincidence with IBICC, atomic, or nuclear reaction induced ion beam analysis signals simultaneously caused by the incident ion.

Doyle, B.L.; Vizkelethy, G.; Walsh, D.S. [Sandia National Labs., Albuquerque, NM (United States); Senftinger, B. [Staib Instrumente GmbH, Langenbach (Germany); Mellon, M. [Quantar Technologies Inc., Santa Cruz, CA (United States)

1998-11-01T23:59:59.000Z

77

HIGH-POWER MILLIMETREWAVE TRANSMISSION SYSTEMS AND COMPONENTS FOR ELECTRON CYCLOTRON HEATING OF FUSION PLASMAS  

Science Journals Connector (OSTI)

At the Institute for Plasma Research at the University of Stuttgart, high-power millimetre wave transmission systems for electron cyclotron heating (ECRH) and current drive (ECCD)...

W. Kasparek; G. Dammertz; V. Erckmann…

2005-01-01T23:59:59.000Z

78

Tailoring of electron flow current in magnetically insulated transmission lines J. P. Martin,2,3  

E-Print Network [OSTI]

Tailoring of electron flow current in magnetically insulated transmission lines J. P. Martin,2,3 M of the drive pulse. It is clear that neither fixed gap nor constant-impedance transmission lines are optimal the impedance profiles developed in a radial disk magnetically insulated transmission line geometry. The input

79

E-Print Network 3.0 - atomic resolution transmission Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Colorado at Boulder Collection: Physics 38 Spectroscopic Imaging of Single AtomsWithin a Bulk Solid S. D. Findlay,2 Summary: transmission electron microscope (STEM) allows not...

80

PROOF COPY 034509PHP Effectiveness of electron-cyclotron and transmission resonant heating  

E-Print Network [OSTI]

PROOF COPY 034509PHP PROOF COPY 034509PHP Effectiveness of electron-cyclotron and transmission resonant heating in inductively coupled plasmas Oleg V. Polomarov and Constantine E. Theodosiou University June 2005 The electron-cyclotron and transmission resonances in magnetically enhanced low-pressure one

Kaganovich, Igor

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Fabrication of curved-line nanostructures on membranes for transmission electron microscopy investigations of domain walls  

E-Print Network [OSTI]

Fabrication of curved-line nanostructures on membranes for transmission electron microscopy, Cambridge CB2 3QZ, United Kingdom Available online 28 February 2006 Abstract We have fabricated curved-line ferromagnetic nanostructures on membranes for transmission electron microscopy investigations of the equilibrium

Dunin-Borkowski, Rafal E.

82

E-Print Network 3.0 - analytical scanning electron Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Electron Microscope Philips CM20 Analytical Scanning... during formation of the carbide particles. 12;Philips CM20 Analytical Scanning Transmission Electron... at SCSAM ...

83

Transmission electron microscopy assisted in-situ joule heat dissipation study of individual InAs nanowires  

SciTech Connect (OSTI)

Managing heat transport at nanoscale is an important and challenging task for nanodevice applications and nanostructure engineering. Herein, through in-situ engineering nanowire (NW)-electrode contacts with electron beam induced carbon deposition in a transmission electron microscope, Joule heat dissipation along individual suspended Indium Arsenide NWs is well managed to obtain pre-designed temperature profiles along NWs. The temperature profiles are experimentally determined by the breakdown site of NWs under Joule heating and breakdown temperature measurement. A model with NW-electrode contacts being well considered is proposed to describe heat transport along a NW. By fitting temperature profiles with the model, thermal conductance at NW-electrode contacts is obtained. It is found that, the temperature profile along a specific NW is mainly governed by the relative thermal conductance at the two NW-electrode contacts, which is engineered in experiments.

Xu, T. T.; Wei, X. L., E-mail: weixl@pku.edu.cn, E-mail: qingchen@pku.edu.cn; Shu, J. P.; Chen, Q., E-mail: weixl@pku.edu.cn, E-mail: qingchen@pku.edu.cn [Key Laboratory for the Physics and Chemistry of Nanodevices and Department of Electronics, Peking University, Beijing 100871 (China)

2013-11-04T23:59:59.000Z

84

Model-independent quantitative measurement of nanomechanical oscillator vibrations using electron-microscope linescans  

SciTech Connect (OSTI)

Nanoscale mechanical resonators are highly sensitive devices and, therefore, for application as highly sensitive mass balances, they are potentially superior to micromachined cantilevers. The absolute measurement of nanoscale displacements of such resonators remains a challenge, however, since the optical signal reflected from a cantilever whose dimensions are sub-wavelength is at best very weak. We describe a technique for quantitative analysis and fitting of scanning-electron microscope (SEM) linescans across a cantilever resonator, involving deconvolution from the vibrating resonator profile using the stationary resonator profile. This enables determination of the absolute amplitude of nanomechanical cantilever oscillations even when the oscillation amplitude is much smaller than the cantilever width. This technique is independent of any model of secondary-electron emission from the resonator and is, therefore, applicable to resonators with arbitrary geometry and material inhomogeneity. We demonstrate the technique using focussed-ion-beam–deposited tungsten cantilevers of radius ?60–170 nm inside a field-emission SEM, with excitation of the cantilever by a piezoelectric actuator allowing measurement of the full frequency response. Oscillation amplitudes approaching the size of the primary electron-beam can be resolved. We further show that the optimum electron-beam scan speed is determined by a compromise between deflection of the cantilever at low scan speeds and limited spatial resolution at high scan speeds. Our technique will be an important tool for use in precise characterization of nanomechanical resonator devices.

Wang, Huan; Fenton, J. C.; Chiatti, O. [London Centre for Nanotechnology, University College London, 17–19 Gordon Street, London WC1H 0AH (United Kingdom)] [London Centre for Nanotechnology, University College London, 17–19 Gordon Street, London WC1H 0AH (United Kingdom); Warburton, P. A. [London Centre for Nanotechnology, University College London, 17–19 Gordon Street, London WC1H 0AH (United Kingdom) [London Centre for Nanotechnology, University College London, 17–19 Gordon Street, London WC1H 0AH (United Kingdom); Department of Electronic and Electrical Engineering, University College London, Torrington Place, London WC1E 7JE (United Kingdom)

2013-07-15T23:59:59.000Z

85

Electronically controllable transmission line design for traveling wave array antenna feed network  

E-Print Network [OSTI]

In this thesis, an electronically controllable transmission line (ECTL) is presented. By modulating the conductivity of a doped Si modulator in the ECTL, the wave propagation constant in the ECTL is controlled. Measured results show a phase...

Shin, Chang-Seok

2012-06-07T23:59:59.000Z

86

Transmission and Backscattering of 4.0- to 12.0-MeV Electrons  

Science Journals Connector (OSTI)

Transmission and backscattering coefficients were measured for 4.0- to 12.0-MeV monoenergetic electrons normally incident on solid targets of C, Al, Cu, Ag, Ta, and U. Transmitted and backscattered electrons were collected by biased Faraday cups, each subtending ?90% of 2? sr. Number transmission coefficients at 10 MeV agree with Berger and Seltzer's Monte Carlo results, and saturation backscattering coefficients generally agree with Tabata's results to within ±10%. Empirical formulas for determining the extrapolated range and both the transmission and backscattering coefficients as a function of Z, energy, and thickness have been developed.

P. J. Ebert, A. F. Lauzon, and E. M. Lent

1969-07-10T23:59:59.000Z

87

The In situ Compression of Annealed Molybdenum Nanopillars in the Transmission Electron Microscope  

E-Print Network [OSTI]

lengths in finite samples. Scr. Mater. 56, 313-316 (2007).prismatic slip orientation. Scr. Mater. 65, 473-476, doi:using a new technique. Scr. Mater. 57, 397-400, doi:

Lowry, Matthew

2011-01-01T23:59:59.000Z

88

Dynamic studies of catalysts for biofuel synthesis in an Environmental Transmission Electron Microscope  

E-Print Network [OSTI]

4. Institute for Microstructure Research, Research Centre Juelich, D-52425 Juelich, Germany ldld resources requires new and better production paths. One approach involves the use of biogas to synthesize

Dunin-Borkowski, Rafal E.

89

The In situ Compression of Annealed Molybdenum Nanopillars in the Transmission Electron Microscope  

E-Print Network [OSTI]

records both load and deflection data as the compressiongathering both load and displacement data. Each of theseacquisition of both load and displacement data during a

Lowry, Matthew

2011-01-01T23:59:59.000Z

90

The In situ Compression of Annealed Molybdenum Nanopillars in the Transmission Electron Microscope  

E-Print Network [OSTI]

funded by the U.S. Department of Energy, Office of Science,Office of Basic Energy Sciences. The author also

Lowry, Matthew

2011-01-01T23:59:59.000Z

91

The In situ Compression of Annealed Molybdenum Nanopillars in the Transmission Electron Microscope  

E-Print Network [OSTI]

GPa; the load drop once again occurs following the escape ofload drop seen in the mechanical data (Fig. 4.25) at 2.40 GPa occurs immediately following

Lowry, Matthew

2011-01-01T23:59:59.000Z

92

Transmission electron microscope as an ultimate tool for nanomaterial property studies  

Science Journals Connector (OSTI)

......for proton exchange membrane fuel cells: multiarmed starlike...high-performance lithium ion batteries. Chem. Commun. (2011...High-performance lithium battery anodes using silicon nanowires...high-performance lithium ion batteries. Chem. Commun. (2011......

Naoyuki Kawamoto; Dai-Ming Tang; Xianlong Wei; Xi Wang; Masanori Mitome; Yoshio Bando; Dmitri Golberg

2013-02-01T23:59:59.000Z

93

Development of a nanostructure thermal property measurement platform compatible with a transmission electron microscope  

E-Print Network [OSTI]

Measurements of the electrical and thermal transport properties of one-dimensional nanostructures (e.g., nanotubes and nanowires) typically are obtained without detailed knowledge of the specimen's atomicscale structure ...

Harris, C. Thomas (Charles Thomas)

2010-01-01T23:59:59.000Z

94

Electron microscopic investigations and indexing studies of psorosis and citrus ringspot virus of citrus / by Margaret Atchison Barkley  

E-Print Network [OSTI]

on 2%%u uranyl acetate for 5 minutes and on lead citrate for 1 minute. Two to three grids were made from each cap- sule. A11 sections were examined with a Hitachi HS-7S electron microscope. 14 CHAPTER IV RESULTS AND DISCUSSION During the spring...

Barkley, Margaret Atchison

1979-01-01T23:59:59.000Z

95

Advanced electron microscopic techniques applied to the characterization of irradiation effects and fission product identification of irradiated TRISO coated particles from the AGR-1 experiment  

SciTech Connect (OSTI)

Preliminary electron microscopy of coated fuel particles from the AGR-1 experiment was conducted using characterization techniques such as scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and wavelength dispersive spectroscopy (WDS). Microscopic quantification of fission-product precipitates was performed. Although numerous micro- and nano-sized precipitates observed in the coating layers during initial SEM characterization of the cross-sections, and in subsequent TEM diffraction patterns, were indexed as UPd{sub 2}Si{sub 2}, no Ag was conclusively found. Additionally, characterization of these precipitates highlighted the difficulty of measuring low concentrations of Ag in precipitates in the presence of significantly higher concentrations of Pd and U. The electron microscopy team followed a multi-directional and phased approach in the identification of fission products in irradiated TRISO fuel. The advanced electron microscopy techniques discussed in this paper, not only demonstrate the usefulness of the equipment (methods) as relevant research tools, but also provide relevant scientific results which increase the knowledge about TRISO fuel particles microstructure and fission products transport.

Rooyen, I.J. van; Lillo, T.M.; Trowbridge, T.L.; Madden, J.M. [Idaho National Laboratory, Idaho Falls, ID 83415-6188 (United States); Wu, Y.Q. [Boise State University, Boise, ID 83725-2090 (United States); Center for Advanced Energy Studies, Idaho Falls, ID 83401 (United States); Goran, D. [Brucker Nano Gmbh, Berlin, 12489 (Germany)

2013-07-01T23:59:59.000Z

96

Transmission  

Broader source: Energy.gov (indexed) [DOE]

Transmission Transmission ,... ,...vc- "' ""'\ S I r;. Dr. Jerry Pell, CCM Principal NEP A Document Manager Permitting, Siting, and Analysis (OE-20) Office of Electricity Delivery and Energy Reliability U.S. Department of Energy 1 000 Independence A venue SW Washington, D.C. 20585-0001 Subject: Champlain Hudson Power Express Project Submittal of Amendment Application Dear Dr. Pell: February 28, 2012 On January 25, 2010, Transmission Developers, Inc. ("TDI") submitted on behalf of Champlain Hudson Power Express, Inc. ("CHPEI") an application to the U.S. Department of Energy ("DOE") for a Presidential Permit ("Application) in connection with the Champlain Hudson Power Express project ("Project"). The Application proposed to connect clean sources

97

Electron microscopic evidence for a tribologically induced phase transformation as the origin of wear in diamond  

SciTech Connect (OSTI)

Tribological testing of a coarse-grained diamond layer, deposited by plasma-enhanced chemical vapor deposition, was performed on a ring-on-ring tribometer with a diamond counterpart. The origin of the wear of diamond and of the low friction coefficient of 0.15 was studied by analyzing the microstructure of worn and unworn regions by transmission and scanning electron microscopy. In the worn regions, the formation of an amorphous carbon layer with a thickness below 100?nm is observed. Electron energy loss spectroscopy of the C-K ionization edge reveals the transition from sp{sup 3}-hybridized C-atoms in crystalline diamond to a high fraction of sp{sup 2}-hybridized C-atoms in the tribo-induced amorphous C-layer within a transition region of less than 5?nm thickness. The mechanically induced phase transformation from diamond to the amorphous phase is found to be highly anisotropic which is clearly seen at a grain boundary, where the thickness of the amorphous layer above the two differently oriented grains abruptly changes.

Zhang, Xinyi; Schneider, Reinhard; Müller, Erich; Gerthsen, Dagmar [Laboratory for Electron Microscopy, Karlsruhe Institute of Technology (KIT), Engesserstr. 7, D-76131 Karlsruhe (Germany); Mee, Manuel; Meier, Sven [Fraunhofer Institute for Mechanics of Materials IWM, Wöhlerstr. 11, D-79108 Freiburg (Germany); Gumbsch, Peter [Fraunhofer Institute for Mechanics of Materials IWM, Wöhlerstr. 11, D-79108 Freiburg (Germany); Institute for Applied Materials IAM, Karlsruhe Institute of Technology (KIT), Kaiserstr. 12, D-76131 Karlsruhe (Germany)

2014-02-14T23:59:59.000Z

98

Transmission electron energy-loss spectroscopy study of carbon nanotubes upon high temperature treatment  

E-Print Network [OSTI]

Transmission electron energy-loss spectroscopy study of carbon nanotubes upon high temperature electron energy-loss spectroscopy study of carbon nanotubes upon high temperature treatment B. W. Reed, M of carbon nanotube materials, grown with a pulsed-laser deposition technique but purified and heat treated

Bertsch George F.

99

Scanning electron microscopic study of laser-induced morphologic changes of a coated enamel surface  

SciTech Connect (OSTI)

A low-energy Nd:YAG laser was used to irradiate extracted human teeth coated with a black energy-absorbent laser initiator in a study to determine the extent of the morphologic changes produced in the enamel surface. The laser initiator was applied to a cleaned enamel surface and irradiated at an energy output of 30 mJ or 75 mJ. Both energy levels produced morphologic changes of the surface. There was a sharp line of demarcation between the coated, irradiated area and the surrounding noncoated enamel surface. The scanning electron microscope view at the lower energy level showed that the surface had melted and reformed with numerous small, bubble-like inclusions. The 75 mJ energy level showed individual impact craters with shallow centers and raised edges containing numerous pores and large, bubble-like inclusions. Etching is a dental procedure in which an acid is normally used to remove a thin outer layer of the tooth structure. This is necessary to create a roughened, irregular surface in order to provide mechanical retention for dental restorative materials. The changes produced by the laser in this study suggest a simple, effective, and controlled method of etching the enamel surface of a tooth by altering its surface characteristics.

Hess, J.A. (Univ. of Detroit School of Dentistry, MI (USA))

1990-01-01T23:59:59.000Z

100

Visualizing Macromolecular Complexes with In Situ Liquid Scanning Transmission Electron Microscopy  

SciTech Connect (OSTI)

A central focus of biological research is understanding the structure/function relationship of macromolecular protein complexes. Yet conventional transmission electron microscopy techniques are limited to static observations. Here we present the first direct images of purified macromolecular protein complexes using in situ liquid scanning transmission electron microscopy. Our results establish the capability of this technique for visualizing the interface between biology and nanotechnology with high fidelity while also probing the interactions of biomolecules within solution. This method represents an important advancement towards allowing future high-resolution observations of biological processes and conformational dynamics in real-time.

Evans, James E.; Jungjohann, K. L.; Wong, Peony C. K.; Chiu, Po-Lin; Dutrow, Gavin H.; Arslan, Ilke; Browning, Nigel D.

2012-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Light and electron microscopic studies of the nanobenthic diatom, Nitzschia ovalis Arnott, Section Lanceolatae, as compared to related forms, and the effect of temperature and salinity on its growth rate  

E-Print Network [OSTI]

and the National Mar'ne Fisheries Service for the use of their Hitachi Transmission Electron Microscope under the auspices of Dr. N. H. Clark, Jr. This study was supported in part by a work ? study program provided by 5'~AA. Sincere gratitude is expressed... in Microdol-X (1:3), and printed on Kodabromide paper. , For TFM examinations, cleaned frustules were pipetted onto a formvar coated grid and air dried or critical point dried as previously described. The specimens were examined ?ith an Hitachi HS-8...

Medlin, Linda Karen

1977-01-01T23:59:59.000Z

102

In situ transmission electron microscopy observation of silver oxidation in ionized/atomic gas.  

SciTech Connect (OSTI)

The interaction between silver and ionized and atomic gas was observed directly by in situ transmission electron microscopy with an environmental cell for the first time. The electron beam provides dual functions as the source of both gas ionization and imaging. The concentration of ionized gas was tuned via adjusting the current density of the electron beam. Oxidation of the silver is observed in situ, indicating the presence of ionized and/or atomic oxygen. The evolution of microstructure and phase constituents was characterized. Then the oxidation rate was measured, and the relationships among grain size, mass transport rate, and electron flux were characterized. The role of the electron beam is discussed, and the results are rationalized with respect to ex situ results from the literature.

Sun, L.; Noh, K. W.; Wen, J-G.; Dillon, S. J. (Materials Science Division); (Massachusetts Inst. Tech.); (Univ. Illinois - Urbana)

2011-10-17T23:59:59.000Z

103

A Novel Method for Passive Digital Image Acquisition from a Scanning Electron Microscope  

E-Print Network [OSTI]

.............................................................................................................. 7 4.1 Frame Grabbing .................................................................................................. 8 4.2 Analog to Digital Converter Sampling ............................................................... 9 4.3 Digitally... generated in one of two methods. An inefficient method for electron beam generation is thermionic emission. In thermionic emission, electrons are emitted by passing electronic current through a heating element, which is usually made from tungsten. A...

Makarewicz, Joseph Sylvester

2009-01-01T23:59:59.000Z

104

Complex modes and new amplification regimes in periodic multi transmission lines interacting with an electron beam  

E-Print Network [OSTI]

We show the existence of a new regime of operation for travelling wave tubes (TWTs) composed of slow-wave periodic structures that support two or more electromagnetic modes, with at least two synchronized with an electron beam. The interaction between the slow-wave structure and an electron beam is quantified using a multi transmission line approach (MTL) and transfer matrix analysis leading to the identification of modes with complex Bloch wavenumber. In particular, we report a new operation condition for TWTs based on an electron beam synchronous to two modes exhibiting a degeneracy condition near a band edge in a MTL slow-wave periodic structure. We show a phenomenological change in the band structure of periodic TWT where we observe at least two growing modal cooperating solutions as opposed to a uniform MTL interacting with an electron beam where there is strictly only one growing mode solution.

Othman, Mohamed; Capolino, Filippo

2014-01-01T23:59:59.000Z

105

Extension of Pierce model to multiple transmission lines interacting with an electron beam  

E-Print Network [OSTI]

A possible route towards achieving high power microwave devices is through the use of novel slow-wave structures employing multiple coupled transmission lines (MTLs) whose behavior when coupled to electron beams have not been sufficiently explored. We present the extension of the one-dimensional linearized Pierce theory to MTLs coupled to a single electron beam. We develop multiple formalisms to calculate the k-{\\omega} dispersion relation of the system and find that the existence of a growing wave solution is always guaranteed if the electron propagation constant is larger than or equal to the largest propagation constant of the MTL system. We verify our findings with illustrative examples which bring to light unique properties of the system in which growing waves were found to exist within finite bands of the electron propagation constant and discuss possible approach to improve the gain. By treating the beam-MTL interaction as distributed dependent current generators in the MTL, we derive relations charact...

Tamma, Venkata Ananth

2013-01-01T23:59:59.000Z

106

New carbon cone nanotip for use in a highly coherent cold field emission electron microscope  

E-Print Network [OSTI]

1 New carbon cone nanotip for use in a highly coherent cold field emission electron Jeanne Marvig, BP 94347, TOULOUSE, Cedex 4, FRANCE Abstract A new cathode for cold-field emission gun using a pyrolytic carbon-cone supported onto a carbon nanotube as the electron emitting tip has been

Paris-Sud XI, Université de

107

In-situ Study of Dynamic Phenomena at Metal Nanosolder Interfaces Using Aberration Corrected Scanning Transmission Electron Microcopy.  

SciTech Connect (OSTI)

Controlling metallic nanoparticle (NP) interactions plays a vital role in the development of new joining techniques (nanosolder) that bond at lower processing temperatures but remain viable at higher temperatures. The pr imary objective of this project is t o develop a fundamental understanding of the actual reaction processes, associated atomic mechanisms, and the resulting microstructure that occur during thermally - driven bond formation concerning metal - metal nano - scale (<50nm) interfaces. In this LDRD pr oject, we have studied metallic NPs interaction at the elevated temperatures by combining in - situ transmission electron microscopy (TEM ) using an aberration - corrected scanning transmission electron microscope (AC - STEM) and atomic - scale modeling such as m olecular dynamic (MD) simulations. Various metallic NPs such as Ag, Cu and Au are synthesized by chemical routines. Numerous in - situ e xperiments were carried out with focus of the research on study of Ag - Cu system. For the first time, using in - situ STEM he ating experiments , we directly observed t he formation of a 3 - dimensional (3 - D) epitaxial Cu - Ag core - shell nanoparticle during the thermal interaction of Cu and Ag NPs at elevated temperatures (150 - 300 o C). The reaction takes place at temperatures as low as 150 o C and was only observed when care was taken to circumvent the effects of electron beam irradiation during STEM imaging. Atomic - scale modeling verified that the Cu - Ag core - shell structure is energetically favored, and indicated that this phenomenon is a nano - scale effect related to the large surface - to - volume ratio of the NPs. The observation potentially can be used for developing new nanosolder technology that uses Ag shell as the %22glue%22 that stic ks the particles of Cu together. The LDRD has led to several journal publications and numerous conference presentations, and a TA. In addition, we have developed new TEM characterization techniques and phase - field modeling tools that can be used for future materials research at Sandia. Acknowledgeme nts This work was supported by the Laboratory Directed Research and Development (LDRD) program of Sandia National Laboratories. Sandia National Laboratories is a multi - program laboratory managed and operated by Sandia Corporation, a wholly owned subsidia ry of Lockheed Martin Corporation, for the US Department of Energy's National Nuclear Security Administration under contract DE - AC04 - 94AL85000.

Lu, Ping

2014-10-01T23:59:59.000Z

108

Young’s double-slit interference experiment with electrons  

Science Journals Connector (OSTI)

In this short Note we report a method for producing samples containing two nano-sized slits suitable for demonstrating to undergraduate and graduate students the double-slit electron interference experiment in a conventional transmission electron microscope.

S. Frabboni; G. C. Gazzadi; G. Pozzi

2007-01-01T23:59:59.000Z

109

Electron microscope studies. Progress report, June 1, 1992--November 1, 1993  

SciTech Connect (OSTI)

During the past year we have continued our work on the mirror-corrected high resolution STEM. We have made significant progress in the design and fabrication of the various microscope sub-systems and have completed a new display system. Additional calculations and computer simulations have been performed to confirm the original theory of mirror correctors. In our biological work we have made a careful study of the structure of globins, vertebrate and invertebrate, using the accumulated information contained in the Brookhaven Data Bank (3D structures), the Protein Identification Resource (ID sequences) and the data we have obtained with the STEM. Statistical templates have been generated to predict various classes of globins.

Crewe, A.V.; Kapp, O.H.

1993-11-01T23:59:59.000Z

110

Electron Microscopy | Center for Functional Nanomaterials  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Electron Microscopy Facility Electron Microscopy Facility Electron Microscopy This facility consists of four top-of-the line transmission electron microscopes, two of which are highly specialized instruments capable of extreme levels of resolution, achieved through spherical aberration correction. The facility is also equipped with extensive sample-preparation capabilities. The scientific interests of the staff focus on understanding the microscopic origin of the physical and chemical behavior of materials, with specific emphasis on in-situ studies of materials in native, functional environments. Capabilities Atomic-resolution imaging of internal materials structure with scanning transmission and transmission electron microscopy Spectroscopic characterization with energy dispersive x-ray

111

Detailed microscopic calculation of stellar electron and positron capture rates on $^{24}$Mg for O+Ne+Mg core simulations  

E-Print Network [OSTI]

Few white dwarfs, located in binary systems, may acquire sufficiently high mass accretion rates resulting in the burning of carbon and oxygen under nondegenerate conditions forming a O+Ne+Mg core. These O+Ne+Mg cores are gravitationally less bound than more massive progenitor stars and can release more energy due to the nuclear burning. They are also amongst the probable candidates for low entropy r-process sites. Recent observations of subluminous Type II-P supernovae (e.g., 2005cs, 2003gd, 1999br, 1997D) were able to rekindle the interest in 8 -- 10 M$_{\\odot}$ which develop O+Ne+Mg cores. Microscopic calculations of capture rates on $^{24}$Mg, which may contribute significantly to the collapse of O+Ne+Mg cores, using shell model and proton-neutron quasiparticle random phase approximation (pn-QRPA) theory, were performed earlier and comparisons made. Simulators, however, may require these capture rates on a fine scale. For the first time a detailed microscopic calculation of the electron and positron captur...

Nabi, Jameel-Un

2014-01-01T23:59:59.000Z

112

Microwave Transmission Measurements of the Electron Cloud density In the Positron Ring of PEP-II  

SciTech Connect (OSTI)

Clouds of electrons in the vacuum chambers of accelerators of positively charged particle beams present a serious limitation for operation of these machines at high currents. Because of the size of these accelerators, it is difficult to probe the low energy electrons clouds over substantial lengths of the beam pipe. We applied a novel technique to directly measure the electron cloud density via the phase shift induced in a TE wave which is independently excited and transmitted over a straight section of the accelerator. The modulation in the wave transmission which appears to increase in depth when the clearing solenoids are switched off, seem to be directly correlated to the electron cloud density in the section. Furthermore, we expect a larger phase shift of a wave transmitted through magnetic dipole field regionsif the transmitted wave couples with the gyration motion of the electrons. We have used this technique to measure the average electron cloud density (ECD) specifically for the first time in magnetic field regions of a new 4-dipole chicane in the positron ring of the PEP-II collider at SLAC. In this paper we present and discuss the measurements taken in the Low Energy Ring (LER) between 2006 and 2008.

Pivi, Mauro T.F.; Krasnykh, Anatoly K.; Byrd, John; De Santis, Stefano; Sonnaad, Kiran G.; Caspers, Fritz; Kroyer, Tom

2008-06-18T23:59:59.000Z

113

Scanning photoelectron microscope for nanoscale three-dimensional spatial-resolved electron spectroscopy for chemical analysis  

E-Print Network [OSTI]

spectroscopy for chemical analysis K. Horiba, Y. Nakamura, N. Nagamura, S. Toyoda, H. Kumigashira et al-level alignment at noble metal/organic interfaces Appl. Phys. Lett. 99, 183302 (2011) Note: Heated sample platform three-dimensional spatial-resolved electron spectroscopy for chemical analysis K. Horiba,1,2,3,a) Y

Miyashita, Yasushi

114

In situ transmission electron microscopy analysis of conductive filament during solid electrolyte resistance switching  

SciTech Connect (OSTI)

An in situ transmission electron microscopy (TEM) analysis of a solid electrolyte, Cu-GeS, during resistance switching is reported. Real-time observations of the filament formation and disappearance process were performed in the TEM instrument and the conductive-filament-formation model was confirmed experimentally. Narrow conductive filaments were formed corresponding to resistance switching from high- to low-resistance states. When the resistance changed to high-resistance state, the filament disappeared. It was also confirmed by use of selected area diffractometry and energy-dispersive x-ray spectroscopy that the conductive filament was made of nanocrystals composed mainly of Cu.

Fujii, Takashi; Arita, Masashi; Takahashi, Yasuo [Graduate School of Information Science and Technology, Hokkaido University, Sapporo 060-0814 (Japan); Fujiwara, Ichiro [Semiconductor Technology Academic Research Center, 3-17-2 Shinyokohama, Kohoku-ku, Yokohama 222-0033 (Japan)

2011-05-23T23:59:59.000Z

115

Structural defects in GaN revealed by Transmission Electron Microscopy  

SciTech Connect (OSTI)

This paper reviews the various types of structural defects observed by Transmission Electron Microscopy in GaN heteroepitaxial layers grown on foreign substrates and homoepitaxial layers grown on bulk GaN substrates. The structural perfection of these layers is compared to the platelet self-standing crystals grown by High Nitrogen Pressure Solution. Defects in undoped and Mg doped GaN are discussed. Some models explaining the formation of inversion domains in heavily Mg doped layers that are possible defects responsible for the difficulties of p-doping in GaN are also reviewed.

Liliental-Weber, Zuzanna

2014-04-18T23:59:59.000Z

116

Defect microstructural evolution in ion irradiated metallic nanofoils: Kinetic Monte Carlo simulation versus cluster dynamics modeling and in situ transmission electron microscopy experiments  

SciTech Connect (OSTI)

Understanding materials degradation under intense irradiation is important for the development of next generation nuclear power plants. Here we demonstrate that defect microstructural evolution in molybdenum nanofoils in situ irradiated and observed on a transmission electron microscope can be reproduced with high fidelity using an object kinetic Monte Carlo (OKMC) simulation technique. Main characteristics of defect evolution predicted by OKMC, namely, defect density and size distribution as functions of foil thickness, ion fluence and flux, are in excellent agreement with those obtained from the in situ experiments and from previous continuum-based cluster dynamics modeling. The combination of advanced in situ experiments and high performance computer simulation/modeling is a unique tool to validate physical assumptions/mechanisms regarding materials response to irradiation, and to achieve the predictive power for materials stability and safety in nuclear facilities.

Xu Donghua; Wirth, Brian D. [Department of Nuclear Engineering, University of Tennessee, Knoxville, Tennessee 37996 (United States); Li Meimei [Division of Nuclear Engineering, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Kirk, Marquis A. [Division of Materials Science, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

2012-09-03T23:59:59.000Z

117

Transmission Electron Microscopy Study of Eu-Doped Y2O3 Nanosheets and Nanotubes  

SciTech Connect (OSTI)

A hydrothermal method was used to synthesize high-purity Eu-doped Y{sub 2}O{sub 3} nanosheets and nanotubes with an approximate molar ratio of (0.1):(1.0) for Eu:Y. High-resolution transmission electron microscopy, energy dispersive X-ray spectroscopy analysis and synchrotron X-ray diffraction were used to characterize these nanomaterials. A body-centered cubic structure was confirmed for the nanotubes. The lattice parameter of Eu-doped Y{sub 2}O{sub 3} nanotubes were 0.12% larger as compared to that of pure Y{sub 2}O{sub 3} which was attributed to the larger ionic radius of Eu{sup 3+} (0.947 {angstrom}) than that of Y{sup 3+} (0.900 {angstrom}). The nanosheets had a similar structure. Nanosheets of approximate dimensions 600 to 800 nm length and width were obtained using a slightly lower pH value, and they were highly textured. The high resolution transmission electron microscopy images showed that the nanotubes are fully crystalline. The nanotubes were typically 1.5-3 {micro}m in length and 50-200 nm in diameter. Using a pH value of approximately 10, stable nanotubes were obtained. It is anticipated that nanosheets might have rolled to form more stable nanotubes.

H Sun; T Chaudhuri; E Kenik; H Zhu; Y Ma

2011-12-31T23:59:59.000Z

118

Detailed microscopic calculation of stellar electron and positron capture rates on $^{24}$Mg for O+Ne+Mg core simulations  

E-Print Network [OSTI]

Few white dwarfs, located in binary systems, may acquire sufficiently high mass accretion rates resulting in the burning of carbon and oxygen under nondegenerate conditions forming a O+Ne+Mg core. These O+Ne+Mg cores are gravitationally less bound than more massive progenitor stars and can release more energy due to the nuclear burning. They are also amongst the probable candidates for low entropy r-process sites. Recent observations of subluminous Type II-P supernovae (e.g., 2005cs, 2003gd, 1999br, 1997D) were able to rekindle the interest in 8 -- 10 M$_{\\odot}$ which develop O+Ne+Mg cores. Microscopic calculations of capture rates on $^{24}$Mg, which may contribute significantly to the collapse of O+Ne+Mg cores, using shell model and proton-neutron quasiparticle random phase approximation (pn-QRPA) theory, were performed earlier and comparisons made. Simulators, however, may require these capture rates on a fine scale. For the first time a detailed microscopic calculation of the electron and positron capture rates on $^{24}$Mg on an extensive temperature-density scale is presented here. This type of scale is more appropriate for interpolation purposes and of greater utility for simulation codes. The calculations are done using the pn-QRPA theory using a separable interaction. The deformation parameter, believed to be a key parameter in QRPA calculations, is adopted from experimental data to further increase the reliability of the QRPA results. The resulting calculated rates are up to a factor of 14 or more enhanced as compared to shell model rates and may lead to some interesting scenario for core collapse simulators.

Jameel-Un Nabi

2014-08-15T23:59:59.000Z

119

Biological Applications and Transmission Electron Microscopy Investigations of Mesoporous Silica Nanoparticles  

SciTech Connect (OSTI)

The research presented and discussed within involves the development of novel biological applications of mesoporous silica nanoparticles (MSN) and an investigation of mesoporous material by transmission electron microscopy (TEM). Mesoporous silica nanoparticles organically functionalized shown to undergo endocytosis in cancer cells and drug release from the pores was controlled intracellularly and intercellularly. Transmission electron microscopy investigations demonstrated the variety of morphologies produced in this field of mesoporous silica nanomaterial synthesis. A series of room-temperature ionic liquid (RTIL) containing mesoporous silica nanoparticle (MSN) materials with various particle morphologies, including spheres, ellipsoids, rods, and tubes, were synthesized. By changing the RTIL template, the pore morphology was tuned from the MCM-41 type of hexagonal mesopores to rotational moire type of helical channels, and to wormhole-like porous structures. These materials were used as controlled release delivery nanodevices to deliver antibacterial ionic liquids against Escherichia coli K12. The involvement of a specific organosiloxane function group, covalently attached to the exterior of fluorescein doped mesoporous silica nanoparticles (FITC-MSN), on the degree and kinetics of endocytosis in cancer and plant cells was investigated. The kinetics of endocystosis of TEG coated FITC-MSN is significantly quicker than FITC-MSN as determined by flow cytometry experiments. The fluorescence confocal microscopy investigation showed the endocytosis of TEG coated-FITC MSN triethylene glycol grafted fluorescein doped MSN (TEG coated-FITC MSN) into both KeLa cells and Tobacco root protoplasts. Once the synthesis of a controlled-release delivery system based on MCM-41-type mesoporous silica nanorods capped by disulfide bonds with superparamagnetic iron oxide nanoparticles was completed. The material was characterized by general methods and the dosage and kinetics of the antioxidant dependent release was measured. Finally, the biological interaction of the material was determined along with TEM measurements. An electron investigation proved that the pore openings of the MSN were indeed blocked by the Fe{sub 3}O{sub 4} nanoparticles. The biological interaction investigation demonstrated Fe{sub 3}O{sub 4}-capped MSN endocytosis into HeLa cells. Not only does the material enter the cells through endocytosis, but it seems that fluorescein was released from the pores most probably caused by disulfide bond reducing molecules, antioxidants. In addition to endocytosis and release, the Fe{sub 3}O{sub 4}-capped MSN propelled the cells across a cuvette upon induction of a magnet force. Finally, an important aspect of materials characterization is transmission electron microscopy. A TEM investigation demonstrated that incorporating different functional groups during the synthesis (co-condensation) changed the particle and pore morphologies.

Brian G. Trewyn

2006-05-01T23:59:59.000Z

120

Correlation between resistance-change effect in transition-metal oxides and secondary-electron contrast of scanning electron microscope images  

SciTech Connect (OSTI)

Conductive atomic-force microscopy (C-AFM) writing is attracting attention as a technique for clarifying the switching mechanism of resistive random-access memory by providing a wide area filled with filaments, which can be regarded as one filament with large radius. The writing area on a nickel-oxide (NiO) film formed by conductive atomic-force microscopy was observed by scanning electron microscope, and a correlation between the contrast in a secondary-electron image (SEI) and the resistance written by C-AFM was revealed. In addition, the dependence of the SEI contrast on the beam accelerating voltage (V{sub accel}) suggests that the resistance-change effect occurs near the surface of the NiO film. As for the effects of electron irradiation and vacuum annealing on the C-AFM writing area, it was shown that the resistance-change effect is caused by exchange of oxygen with the atmosphere at the surface of the NiO film. This result suggests that the low-resistance and high-resistance areas are, respectively, p-type Ni{sub 1+{delta}}O ({delta} < 0) and insulating (stoichiometric) or n-type Ni{sub 1+{delta}}O ({delta}{>=} 0).

Kinoshita, K.; Kishida, S. [Department of Information and Electronics, Graduate School of Engineering, Tottori University, 4-101 Koyama-Minami, Tottori 680-8552 (Japan); Tottori University Electronic Display Research Center, 522-2 Koyama-Kita, Tottori 680-0941 (Japan); Yoda, T. [Department of Information and Electronics, Graduate School of Engineering, Tottori University, 4-101 Koyama-Minami, Tottori 680-8552 (Japan)

2011-09-15T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Crystal structure of Si3N4·Y2O3 examined by a 1 MV high-resolution electron microscope  

Science Journals Connector (OSTI)

The crystal structure of Si3N4·Y2O3...prepared by a hot-press is examined in a 1 MV high-resolution electron microscope. The image contrast reveals that it is isostructural with one of the layered silicates, Akermanite

S. Horiuchi; M. Mitomo

1979-11-01T23:59:59.000Z

122

Electron microscope studies. Progress report, 1 July 1990--1 June 1991  

SciTech Connect (OSTI)

This year our laboratory has continued to make progress in the design of electron-optical systems, in the study of structure-function relationships of large multi-subunit proteins, in the development of new image processing software and in achieving a workable sub-angstrom STEM. We present an algebraic approach to the symmetrical Einzel (unipotential) lens wherein we simplify the analysis by specifying a field shape that meets some preferred set of boundary or other conditions and then calculate the fields. In a second study we generalize this approach to study of three element electrostatic lenses of which the symmetrical Einzel lens is a particular form. The purpose is to develop a method for assisting in the design of a lens for a particular purpose. In our biological work we study a stable and functional dodecameric complex of globin chains from the hemoglobin of Lumbricus terrestris. This is a complex lacking the ``linker`` subunit first imaged in this lab and required for maintenance of the native structure. In addition, we do a complete work-up on the hemoglobin of the marine polychaete Eudistylia vancouverii demonstrating the presence of a hierarchy of globin complexes. We demonstrate stable field-emission in the sub-angstrom STEM and the preliminary alignment of the beam. We continue our exploration of a algorithms for alignment of sequences of protein and DNA. Our computer facilities now include four second generation RISC workstations and we continue to take increasing advantage of the floating-point and graphical performance of these devices.

Crewe, A.V.; Kapp, O.H.

1991-06-01T23:59:59.000Z

123

A scanning electron microscope study on agglomeration in petroleum coke-fired FBC boilers  

Science Journals Connector (OSTI)

Ten samples originating from different boiler FBC systems burning petroleum coke and one laboratory sample were chosen to perform a study on the development, structure, and composition of deposits formed by agglomeration in various locations. The work focused on examination by scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) analysis. The possibility of a contribution of liquid phases in the adherence to solid surfaces and in agglomeration was discussed and checks by SEM, EDX, and analysis by neutron activation were performed; no evidence could be found either for liquid phases or for any role of vanadium or alkaline element compounds. The agglomerations result from the continued sintering of CaSO4 particles until they build up a strong framework that is indefinitely extended, into which particles of different and complex compositions are bound, without contributing to the cohesion. Chemical sintering occurring by the sulphation of CaO into CaSO4 appears to be an important contribution while CaO is still available, but sintering also occurs by mass transfer mechanisms and continues after the depletion of CaO. Deposits formed in regions only reached by fly ash (convection section), and also in in-bed deposits, grow from particles <50 ?m, mostly in the range of 10 ?m or less. In regions collecting bed ash (e.g., J-valves), the deposit grows from the sintering together of particles on the order of 100–300 ?m (originally bed ash particles), which themselves appear as conglomerates of extensively sintered smaller particles.

J.V Iribarne; E.J Anthony; A Iribarne

2003-01-01T23:59:59.000Z

124

E-Print Network 3.0 - analytical transmission electron Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

through a Slit Aperture E... ) We demonstrate optical control over the transmission of terahertz (THz) radiation through a single... can contribute to the transmission. A...

125

Los Alamos: MST-MTM: EML: Electron Microscopy Laboratory  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3000F High Resolution Transmission Electron Microscope 3000F High Resolution Transmission Electron Microscope JEOL 3000F High Resolution Transmission Electron Microscope This is a high-resolution TEM equipped with an electron energy-loss spectrometer and a CCD camera for digital image acquisition. This microscope is used primarily for imaging the atomic structure of defects and interfaces in materials. Field emission electron source. Coherent source with an energy spread of 0.8 eV. Operation at accelerating voltages of up to 300 kV. +/- 10° of eucentric specimen tilt. Point to point resolution of 0.17 nm; 0.10 nm resolution can be extracted by computer processing. Gatan Multiscan CCD Camera for digital image acquisition. Automated microscope alignment: defocus calibration/adjustment, astigmatism correction and beam-tilt correction (automatic coma-free alignment).

126

Characterization of polysilicon films by Raman spectroscopy and transmission electron microscopy: A comparative study  

SciTech Connect (OSTI)

Samples of chemically-vapor-deposited micrometer and sub-micrometer-thick films of polysilicon were analyzed by transmission electron microscopy (TEM) in cross-section and by Raman spectroscopy with illumination at their surface. TEM and Raman spectroscopy both find varying amounts of polycrystalline and amorphous silicon in the wafers. Raman spectra obtained using blue, green and red excitation wavelengths to vary the Raman sampling depth are compared with TEM cross-sections of these films. Films showing crystalline columnar structures in their TEM micrographs have Raman spectra with a band near 497 cm{sup {minus}1} in addition to the dominant polycrystalline silicon band (521 cm{sup {minus}1}). The TEM micrographs of these films have numerous faulted regions and fringes indicative of nanometer-scale silicon structures, which are believed to correspond to the 497cm{sup {minus}1} Raman band.

Tallant, D.R.; Headley, T.J.; Medernach, J.W. [Sandia National Labs., Albuquerque, NM (United States); Geyling, F. [SEMATECH, Austin, TX (United States)

1993-11-12T23:59:59.000Z

127

Novel scheme for the preparation of transmission electron microscopy specimens with a focused ion beam  

Science Journals Connector (OSTI)

A novel scheme is presented for the preparation of cross?section transmission electron microscopy(TEM) specimens with a focused ion beam(FIB). This scheme is particularly suitable for highly structured substrates such as integrated circuits. The specimen is made by cutting a thin slice of material from the substrate by sputtering with the FIB. The position of the specimen can be selected with submicron resolution. The specimen is subsequently removed from the substrate and transported to a standard TEM?specimen holder. A specimen ready for TEM inspection can be prepared within 2 hs. The samples are of excellent quality as is illustrated with cross?section TEM images of FIB?made specimens of an electrically programmable read?only memory.

M. H. F. Overwijk; F. C. van den Heuvel; C. W. T. Bulle?Lieuwma

1993-01-01T23:59:59.000Z

128

Advances in cryogenic transmission electron microscopy for the characterization of dynamic self-assembling nanostructures  

Science Journals Connector (OSTI)

Elucidating the structural information of nanoscale materials in their solvent-exposed state is crucial, as a result, cryogenic transmission electron microscopy (cryo-TEM) has become an increasingly popular technique in the materials science, chemistry, and biology communities. Cryo-TEM provides a method to directly visualize the specimen structure in a solution-state through a thin film of vitrified solvent. This technique complements X-ray, neutron, and light scattering methods that probe the statistical average of all species present; furthermore, cryo-TEM can be used to observe changes in structure over time. In the area of self-assembly, this tool has been particularly powerful for the characterization of natural and synthetic small molecule assemblies, as well as hybrid organic–inorganic composites. In this review, we discuss recent advances in cryogenic TEM in the context of self-assembling systems with emphasis on characterization of transitions observed in response to external stimuli.

Christina J. Newcomb; Tyson J. Moyer; Sungsoo S. Lee; Samuel I. Stupp

2012-01-01T23:59:59.000Z

129

Transmission electron microscopy of oxide dispersion strengthened (ODS) molybdenum: effects of irradiation on material microstructure  

SciTech Connect (OSTI)

Oxide dispersion strengthened (ODS) molybdenum has been characterized using transmission electron microscopy (TEM) to determine the effects of irradiation on material microstructure. This work describes the results-to-date from TEM characterization of unirradiated and irradiated ODS molybdenum. The general microstructure of the unirradiated material consists of fine molybdenum grains (< 5 {micro}m average grain size) with numerous low angle boundaries and isolated dislocation networks. 'Ribbon'-like lanthanum oxides are aligned along the working direction of the product form and are frequently associated with grain boundaries, serving to inhibit grain boundary and dislocation movement. In addition to the 'ribbons', discrete lanthanum oxide particles have also been detected. After irradiation, the material is characterized by the presence of nonuniformly distributed large ({approx} 20 to 100 nm in diameter), multi-faceted voids, while the molybdenum grain size and oxide morphology appear to be unaffected by irradiation.

Baranwal, R. and Burke, M.G.

2003-03-03T23:59:59.000Z

130

Rendering graphene supports hydrophilic with non-covalent aromatic functionalization for transmission electron microscopy  

SciTech Connect (OSTI)

Amorphous carbon films have been routinely used to enhance the preparation of frozen-hydrated samples for transmission electron microscopy (TEM), either in retaining protein concentration, providing mechanical stability or dissipating sample charge. However, strong background signal from the amorphous carbon support obstructs that of the sample, and the insulating properties of thin amorphous carbon films preclude any efficiency in dispersing charge. Graphene addresses the limitations of amorphous carbon. Graphene is a crystalline material with virtually no phase or amplitude contrast and unparalleled, high electrical carrier mobility. However, the hydrophobic properties of graphene have prevented its routine application in Cryo-TEM. This Letter reports a method for rendering graphene TEM supports hydrophilic—a convenient approach maintaining graphene's structural and electrical properties based on non-covalent, aromatic functionalization.

Pantelic, Radosav S., E-mail: pantelic@imbb.forth.gr [National Cancer Institute, 50 South Drive, Building 50, Room 4306, Bethesda, Maryland 20892 (United States); Fu, Wangyang; Schoenenberger, Christian [Department of Physics, University of Basel, Klingelbergstrasse 82, Basel CH-4056 (Switzerland); Stahlberg, Henning [Center for Cellular Imaging and NanoAnalytics, Biozentrum, University of Basel, Mattenstrasse 26, WRO-1058, Basel CH-4058 (Switzerland)

2014-03-31T23:59:59.000Z

131

Transmission electron microscope study of polyphase and discordant monazites: Site-specific specimen preparation using the focused ion beam technique  

Science Journals Connector (OSTI)

...nm thick (for technical details, see Overwijk et al., 1993; Young, 1997; Roberts...Chemical Geology, v. 191p. 89-104. Overwijk, M.H.F., van den Heuvel, F...nm thick (for technical details, see Overwijk et al., 1993; Young, 1997; Roberts...

132

Estimation of wave fields of incident beams in a transmission electron microscope by using a small selected-area aperture  

Science Journals Connector (OSTI)

......analysis at atomic dimensions. Cryst. Res. Technol. (2005) 40:149-160. doi:10.1002/crat.200410318 . 4 Thust A , Overwijk M H F, Coene W M J, Lentzen M. Numerical correction of lens aberrations in phase-retrieval HRTEM. Ultramicroscopy (1996......

Shigeyuki Morishita; Jun Yamasaki; Nobuo Tanaka

2011-04-01T23:59:59.000Z

133

Reading Comprehension - Microscopes  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Microscopes Microscopes It happened over 300 years _________ since ago before after in Holland. Anton van Leeuwenhoek (AN-tun van LAY-vun-hook) had a new microscope that he had _________ made lost previewed delivered . One day he _________ fell broke looked went through it at a drop of lake water. What he saw surprised him. The water was alive with what Leeuwenhoek called "wee beasties." The microscope made tiny organisms look 200 times _________ farther smaller darker larger than life size. Leeuwenhoek was one of the first scientists to see living things that were that _________ life small darker larger . His work was a giant _________ turtle gorilla step tower for science. Today, microscopes are much stronger. An electron microscope can make tiny organisms look 200,000 times _________ small over under life size. A few

134

Beam damage suppression of low- porous Si–O–C films by cryo-electron-energy loss spectroscopy (EELS)  

Science Journals Connector (OSTI)

......plasma processes studied by energy filtered and analytical...Egerton R F . Electron Energy Loss Spectroscopy in the...Microscope (1996) 2nd edn. New York: Plenum. 277-288...Transmission Electron Energy Loss spectrometry in Materials......

Yuji Otsuka; Yumiko Shimizu; Isao Tanaka

2009-04-01T23:59:59.000Z

135

Fish scale deformation analysis using scanning electron microscope: New potential biomarker in aquatic environmental monitoring of aluminum and iron contamination  

SciTech Connect (OSTI)

Fish scale has the potential to be a rapid biomarker due to its structure and high possibility to come into contact with any pollutant in the aquatic environment. The scale structure consists of osteoblastic cells and other bone materials such as collagen where it is possible to form a molecular complex with heavy metals such as aluminum and iron. Hence, aluminum and iron in water could possibly destroy the scale material and marked as a scale deformation that quantitatively could be analyzed by comparing it to the normal scale structure. Water sampling and fish cage experiment were performed between June and July 2011 in Porong river which represented the water body that has high aluminum and iron contamination. The filtered water samples were preserved and extracted using the acid-mixture procedure prior to measurement of the aluminum and iron concentrations using Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), while samples for total suspended solid (TSS) analysis were kept at 4 °C in cool-boxes. The scales were cleaned with sterile water, then dehydrated in 30, 50, 70, and 90% ethanol and dried on filter papers. They were then mounted on an aluminum stub and coated with gold in a sputter coater prior to Scanning Electron Microscope (SEM) observation. According to the SEM analysis, it was found that there were several deformations on the scale samples taken from sites that have high concentrations of aluminum and iron i.e. the increasing number of pits, deformation and decreasing number of spherules and ridges while the control scale exhibited the normal features. However, the site with higher TSS and pH indicated lower aluminum effect. A moderate correlation was found between the number of pits with aluminum (r=0.43) and iron (r=0.41) concentrations. Fish scale deformation using SEM analysis can potentially be a rapid biomarker in aquatic monitoring of aluminum and iron contamination. However, the measurement must be accompanied by pH and TSS observations.

Hidayati, Dewi; Sulaiman, Norela; Othman, Shuhaimi; Ismail, B. S. [School of Environmental and Natural Resource Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia)

2013-11-27T23:59:59.000Z

136

Microstructure of highly strained BiFeO{sub 3} thin films: Transmission electron microscopy and electron-energy loss spectroscopy studies  

SciTech Connect (OSTI)

Microstructure and electronic structure of highly strained bismuth ferrite (BiFeO{sub 3}) thin films grown on lanthanum aluminate substrates are studied using high-resolution transmission and scanning transmission electron microscopies and electron energy loss spectroscopy (EELS). Monoclinic and tetragonal phases were observed in films grown at different temperatures, and a mix of both phases was detected in a film grown at intermediate temperature. In this film, a smooth transition of the microstructure was found between the monoclinic and the tetragonal phases. A considerable increase in the c-axis parameters was observed in both phases compared with the rhombohedral bulk phase. The off-center displacement of iron (Fe) ions was increased in the monoclinic phase as compared with the tetragonal phase. EEL spectra show different electronic structures in the monoclinic and the tetragonal phases. These experimental observations are well consistent with the results of theoretical first-principle calculations performed.

Heon Kim, Young, E-mail: young.h.kim@kriss.re.kr [Max Planck Institute of Microstructure Physics, Weinberg 2, D-06120 Halle (Germany); Korea Research Institute of Standards and Science (KRISS), Daejeon 305-340 (Korea, Republic of); Bhatnagar, Akash; Pippel, Eckhard; Hesse, Dietrich [Max Planck Institute of Microstructure Physics, Weinberg 2, D-06120 Halle (Germany); Alexe, Marin [Max Planck Institute of Microstructure Physics, Weinberg 2, D-06120 Halle (Germany); University of Warwick, Coventry CV4 7AL, West Midlands (United Kingdom)

2014-01-28T23:59:59.000Z

137

Transmission electron microscopy study of the effect of selenium doping on the ordering of GalnP2  

Science Journals Connector (OSTI)

Selenium doped Ga0.51In0.49P films have been grown by metalorganic chemical vapour deposition at 600, 670 and 740° C. The extent of ordering of the Group III sublattice has been monitored by transmission electron...

J. P. Goral; Sarah R. Kurtz; J. M. Olson; A. Kibbler

138

The Engineering Analysis in Support of the ITER Electron Cyclotron Heating and Current Drive Transmission Lines  

Science Journals Connector (OSTI)

Technical Paper / Sixteenth Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Resonance Heating (EC-16)

D. M. S. Ronden; M. A. Henderson; B. Becket; T. Bigelow; J. Caughman; C. Darbos; F. Gandini; C. Nazare; D. Rasmussen; V. Udintsev

139

Spatial resolution limits in electron-beam-induced deposition N. Silvis-Cividjian, C. W. Hagen,a  

E-Print Network [OSTI]

were written in a 200-kV STEM on a 30-nm SiN membrane. © 2005 American Institute of Physics. DOI: 10-beam instruments, such as scanning electron microscopes, scanning transmission electron microscopes STEM of a singular deposited dot or line, always exceeds the diameter of the electron beam. Until recently, no one

Silvis-Cividjian, Natalia

140

TRANSMISSION ELECTRON MICROSCOPY OF Al-RICH SILICATE STARDUST FROM ASYMPTOTIC GIANT BRANCH STARS  

SciTech Connect (OSTI)

We report on transmission electron microscopy (TEM) investigations of two mineralogically unusual stardust silicates to constrain their circumstellar condensation conditions. Both grains were identified by high spatial resolution nano secondary ion mass spectrometry (NanoSIMS) in the Acfer 094 meteorite, one of the most pristine carbonaceous chondrites available for study. One grain is a highly crystalline, highly refractory (Fe content < 0.5 at%), structurally undisturbed orthopyroxene (MgSiO{sub 3}) with an unusually high Al content (1.8 {+-} 0.5 at%). This is the first TEM documentation of a single crystal pyroxene within the complete stardust silicate data set. We interpret the microstructure and chemistry of this grain as being a direct condensate from a gas of locally non-solar composition (i.e., with a higher-than-solar Al content and most likely also a lower-than-solar Mg/Si ratio) at (near)-equilibrium conditions. From the overabundance of crystalline olivine (six reported grains to date) compared to crystalline pyroxene (only documented as a single crystal in this work) we infer that formation of olivine over pyroxene is favored in circumstellar environments, in agreement with expectations from condensation theory and experiments. The second stardust silicate consists of an amorphous Ca-Si rich material which lacks any crystallinity based on TEM observations in which tiny (<20 nm) hibonite nanocrystallites are embedded. This complex assemblage therefore attests to the fast cooling and rapidly changing chemical environments under which dust grains in circumstellar shells form.

Vollmer, Christian [Institute for Mineralogy, University of Muenster, Correnssstr. 24, D-48149 Muenster (Germany); Hoppe, Peter [Max Planck Institute for Chemistry, Particle Chemistry Department, Hahn-Meitner-Weg 1, D-55128 Mainz (Germany); Brenker, Frank E., E-mail: christian.vollmer@wwu.de [Institute of Geoscience/Mineralogy, Goethe-University Frankfurt, Altenhoeferallee 1, D-60438 Frankfurt (Germany)

2013-05-20T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

VOLUME 71, NUMBER 21 PH YSICAL R EV I EW LETTERS 22 NOVEMBER 1993 Structure of Si(100)-(2 x 1) Surface Using UHV Transmission Electron Diffraction  

E-Print Network [OSTI]

) Surface Using UHV Transmission Electron Diffraction Ganesh Jayaram, P. Xu, and L. D. Marks Department) Details of the atomic structure for the Si(100)-(2X1) surface using UHV transmission electron diffraction]), ultrahigh vacuum (UHV) conditions are therefore paramount. In this Letter, we present details

Marks, Laurence D.

142

Instrument Series: Microscopy Aberration-Corrected Scanning/Transmission  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Aberration-Corrected Aberration-Corrected Scanning/Transmission Electron Microscope EMSL's aberration-corrected Titan 80-300(tm) scanning/transmission electron microscope (S/TEM) provides high-resolution imaging with sub-angstrom resolution and spectroscopic capabilities. This state-of-the-art instrument is equipped with a Schottky field-emission electron source, an electron gun monochromator, CEOS hexapole spherical aberration corrector for the probe-forming lens, high-angle annular dark field (HAADF) detector, an X-ray spectrometer (EDS), and a high-resolution Gatan Imaging Filter (GIF). The selection of electron energy between 80 kV and 300 kV enables optimized imaging for a variety of samples, including electron beam sensitive materials. Research Applications

143

Probing the electronic structure of graphene sheets with various thicknesses by scanning transmission X-ray microscopy  

SciTech Connect (OSTI)

The electronic structure of an aggregation of graphene sheets with various thicknesses was probed by scanning transmission X-ray microscopy. A uniform oxidation of the graphene sheets in the flat area was observed regardless of the thickness, while in the folded area the result could be strongly affected by the geometry. Moreover, thick parts of the aggregation showed strong angle-dependence to the incident X-ray, while thin parts showed less angle-dependence, which might be related to the surface wrinkles and ripples. The electronic structure differences due to the geometry and thickness suggest a complicated situation in the aggregation of graphene sheets.

Bai, Lili; Liu, Jinyin; Zhao, Guanqi; Gao, Jing; Sun, Xuhui, E-mail: xhsun@suda.edu.cn, E-mail: jzhong@suda.edu.cn; Zhong, Jun, E-mail: xhsun@suda.edu.cn, E-mail: jzhong@suda.edu.cn [Soochow University-Western University Centre for Synchrotron Radiation Research, Institute of Functional Nano and Soft Materials Laboratory (FUNSOM) and Collaborative Innovation Center of Suzhou Nano Science and Technology, Soochow University, Suzhou 215123 (China)] [Soochow University-Western University Centre for Synchrotron Radiation Research, Institute of Functional Nano and Soft Materials Laboratory (FUNSOM) and Collaborative Innovation Center of Suzhou Nano Science and Technology, Soochow University, Suzhou 215123 (China)

2013-12-16T23:59:59.000Z

144

Electron Microscopy Lab  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Facilities » Facilities » Electron Microscopy Lab Electron Microscopy Lab Focusing on the study of microstructures with electron and ion beam instruments, including crystallographic and chemical techniques. April 12, 2012 Transmission electron microscope Rob Dickerson examines a multiphase oxide scale using the FEI Titan 80-300 transmission electron microscope. Contact Rob Dickerson (505) 667-6337 Email Rod McCabe (505) 606-1649 Email Pat Dickerson (505) 665-3036 Email Tom Wynn (505) 665-6861 Email Dedicated to the characterization of materials through imaging, chemical, and crystallographic analyses of material microstructures in support of Basic Energy Science, Laboratory Directed Research and Development, DoD, DOE, Work for Others, nuclear energy, and weapons programs. Go to full website »

145

High-energy-resolution monochromator for aberration-corrected scanning transmission electron microscopy/electron energy-loss spectroscopy  

Science Journals Connector (OSTI)

...equal to the beam current per unit area per unit solid angle per unit energy interval, CFE electron sources with their...Monochromated, spatially resolved electron energy-loss spectroscopic measurements of gold nanoparticles in the plasmon range...

2009-01-01T23:59:59.000Z

146

The TE Wave Transmission Method for Electron Cloud Measurements at Cesr-TA  

E-Print Network [OSTI]

CLOUD MEASUREMENTS AT CESR-TA* S. De Santis # , J. Byrd,Wave measurements at the Cesr-TA ring at Cornell University.CBP-836 THE TE WAVE TRANSMISSION METHOD FOR

Desantis, S.

2010-01-01T23:59:59.000Z

147

Assembly of Large Three-Dimensional Volumes from Serial-Section Transmission Electron Microscopy  

E-Print Network [OSTI]

Pavel Koshevoy1, Tolga Tasdizen1, Ross Whitaker1, Bryan Jones2 and Robert Marc2 1Scientific Computing size and limited field of view: each section must be assembled from many overlapping tiles, a process, data-driven descriptions of microscopic structures are very important in neurobiology. While neural

Utah, University of

148

New views of materials through aberration-corrected scanning transmission electron microscopy  

Science Journals Connector (OSTI)

......analysis to solving energy problems. Phil...eds. (2007) New York: Springer...and electron energy loss spectroscopy...eds. (2011) New York: Springer...for electron energy loss spectroscopy...can now give new insights into......

S. J. Pennycook; M. Varela

2011-08-01T23:59:59.000Z

149

Room temperature electron transport properties of single C{sub 60} studied using scanning tunneling microscope and reak junctions.  

SciTech Connect (OSTI)

We report the measurements of the electron transport of an individual C{sub 60} molecule through the combination of two experimental efforts. The nanometer-sized junctions were fabricated using electromigration combined with electron beam lithography and shadow effect evaporation. We performed the scanning tunneling microscopy/spectroscopy measurements of dispersed C{sub 60} molecules which were deposited on a highly ordered pyrolytic graphite substrate. The single electron tunneling through a single C{sub 60} molecule due to the Coulomb blockage effect is observed at room temperature.

Cheng, R.; Carvell, J.; Fradin, F. Y.; Indiana Univ.-Purdue Univ. at Indianapolis

2010-09-15T23:59:59.000Z

150

In situ transmission electron microscopy investigation of the interfacial reaction between Ni and Al during rapid heating in a nanocalorimeter  

SciTech Connect (OSTI)

The Al/Ni formation reaction is highly exothermic and of both scientific and technological significance. In this report, we study the evolution of intermetallic phases in this reaction at a heating rate of 830 K/s. 100-nm-thick Al/Ni bilayers were deposited onto nanocalorimeter sensors that enable the measurement of temperature and heat flow during rapid heating. Time-resolved transmission electron diffraction patterns captured simultaneously with thermal measurements allow us to identify the intermetallic phases present and reconstruct the phase transformation sequence as a function of time and temperature. The results show a mostly unaltered phase transformation sequence compared to lower heating rates.

Grapes, Michael D., E-mail: mgrapes1@jhu.edu, E-mail: david.lavan@nist.gov, E-mail: weihs@jhu.edu [Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Material Measurement Laboratory, Materials Measurement Science Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); LaGrange, Thomas; Reed, Bryan W.; Campbell, Geoffrey H. [Lawrence Livermore National Laboratory, Materials Science and Technology Division, Livermore, California 94550 (United States); Woll, Karsten [Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Institute of Applied Materials, Karlsruhe Institute of Technology, 76344 Eggenstein-Leopoldshafen (Germany); LaVan, David A., E-mail: mgrapes1@jhu.edu, E-mail: david.lavan@nist.gov, E-mail: weihs@jhu.edu [Material Measurement Laboratory, Materials Measurement Science Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Weihs, Timothy P., E-mail: mgrapes1@jhu.edu, E-mail: david.lavan@nist.gov, E-mail: weihs@jhu.edu [Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218 (United States)

2014-11-01T23:59:59.000Z

151

Studying Fischer-Tropsch catalysts using transmission electron microscopy and model systems of nanoparticles on planar supports.  

SciTech Connect (OSTI)

Nanoparticle model systems on planar supports form a versatile platform for studying morphological and compositional changes of catalysts due to exposure to realistic reaction conditions. We review examples from our work on iron and cobalt catalysts, which can undergo significant rearrangement in the reactive environment of the Fischer-Tropsch synthesis. The use of specially designed, silicon based supports with thin film SiO{sub 2} enables the application of transmission electron microscopy, which has furnished important insight into e.g. the mechanisms of catalyst regeneration.

Thune, P. C.; Weststrate, C. J.; Moodley, P.; Saib, A. M.; van de Loosdrecht, J.; Miller, J. T.; Niemantsverdriet, J. W. (Chemical Sciences and Engineering Division); (Eindhoven Univ. of Technology); (Sasol Technology)

2011-01-01T23:59:59.000Z

152

Particle analysis for a strengthened safeguards system: Use of a scanning electron microscope equipped with EDXRF and WDXRF spectrometers  

Science Journals Connector (OSTI)

The purpose of this study was twofold: the identification of some uranium compounds and a measurement of mixed U/Pu particles with different ratios of these elements. We used a Philips XL-30 scanning electron ...

A. Ciurapinski; J. Parus; D. Donohue

2002-03-01T23:59:59.000Z

153

Neutron Microscope  

Science Journals Connector (OSTI)

We report successful operation of a neutron microscope using ultracold neutrons at the high-flux reactor at Grenoble. A sharp, achromatic image of an object slit was obtained at a magnification of 50. The measured resolution of 0.1 mm was limited mainly by the available beam intensity, not by aberrations.

P. Herrmann; K. -A. Steinhauser; R. Gähler; A. Steyerl; W. Mampe

1985-05-06T23:59:59.000Z

154

Ultrafast supercontinuum fiber-laser based pump-probe scanning magneto-optical Kerr effect microscope for the investigation of electron spin dynamics in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution  

SciTech Connect (OSTI)

We describe a two-color pump-probe scanning magneto-optical Kerr effect microscope which we have developed to investigate electron spin phenomena in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution. The key innovation of our microscope is the usage of an ultrafast “white light” supercontinuum fiber-laser source which provides access to the whole visible and near-infrared spectral range. Our Kerr microscope allows for the independent selection of the excitation and detection energy while avoiding the necessity to synchronize the pulse trains of two separate picosecond laser systems. The ability to independently tune the pump and probe wavelength enables the investigation of the influence of excitation energy on the optically induced electron spin dynamics in semiconductors. We demonstrate picosecond real-space imaging of the diffusive expansion of optically excited electron spin packets in a (110) GaAs quantum well sample to illustrate the capabilities of the instrument.

Henn, T.; Kiessling, T., E-mail: tobias.kiessling@physik.uni-wuerzburg.de; Ossau, W.; Molenkamp, L. W. [Physikalisches Institut (EP3), Universität Würzburg, 97074 Würzburg (Germany)] [Physikalisches Institut (EP3), Universität Würzburg, 97074 Würzburg (Germany); Biermann, K.; Santos, P. V. [Paul-Drude-Institut für Festkörperelektronik, 10117 Berlin (Germany)] [Paul-Drude-Institut für Festkörperelektronik, 10117 Berlin (Germany)

2013-12-15T23:59:59.000Z

155

Total energy study of the microscopic structure and electronic properties of tetragonal perovskite SrTiO{sub 3}  

SciTech Connect (OSTI)

To study the structural and electronic properties of cubic perovskite SrTiO{sub 3} and its stress-induced tetragonal phase, we have performed total energy calculations and studied the effect of oxygen vacancies on the electronic properties of tetragonal perovskite SrTiO{sub 3}. The method used was the relativistic full-potential linearized augmented plane wave (FLAPW) method. To obtain the geometry that minimizes the total energy, we relaxed the internal atomic sites of the tetragonal cell. As a result of this procedure, we have found that the titanium atoms move toward the plane of the vacancy by 0.03 Å, and the apical oxygen atoms move to the same plane by approximately 0.14 Å. These results are discussed in comparison with experimental data.

Rubio-Ponce, A. [Departamento de Ciencias Básicas, Universidad Autónoma Metropolitana-Azcapotzalco, Av. San Pablo 180, 02200 México, D.F. (Mexico); Olguín, D. [Departamento de Física, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, A.P. 14740, México, D.F. (Mexico)

2014-05-15T23:59:59.000Z

156

Electron Microscopy Center  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

iTEAM iTEAM The in situ Transmission Electron Aberration Corrected Microscope (iTEAM) is a proposed project to develop a microscope with powerful capabilities for in situ studies of materials in their native environment. iTEAM will build on the success of the TEAM project by utilizing both spherical and chromatic aberration correction in an electron microscope to provide unprecedented capabilities to study materials in controlled environments of temperature, pressure, or fluidic states with the high-resolution in imaging, diffraction, and spectroscopy typical of electron probes. The capabilities of iTEAM will lead to new ways to understand the behavior of materials in native environments, with particular relevance to major energy initiatives such as catalysis, solar conversion, fuel cells, and batteries. In addition, iTEAM will provide new capabilities to understand organic/inorganic interfaces, functionalized nanoparticles, and biomaterials under natural conditions.

157

IEEE ELECTRON DEVICE LETTERS, VOL. 30, NO. 5, MAY 2009 433 RF Transmission Line Method for  

E-Print Network [OSTI]

. Jain, J. Yang, X. Hu, and R. Gaska are with Sensor Electronic Technology, Inc., Columbia, SC 29209 USA model (TLM) technique, which em- ploys the C3 electrodes. The technique is applied Polytechnic Institute, Troy, NY 12180 USA (e-mail: shurm13@gmail.com). N. Pala was with Rensselaer Polytechnic

Pala, Nezih

158

Structural Transformations in self-assembled Semiconductor Quantum Dots as inferred by Transmission Electron Microscopy  

E-Print Network [OSTI]

electronic and optoelectronic devices.1-3 ZnO is a promising material for UV optoelectronics due to its of the results have been widely reproduced or resulted in stable optoelectronic devices. p-type ZnO NWs have also

Moeck, Peter

159

Three-dimensional imaging of copper pillars using x-ray tomography within a scanning electron microscope: A simulation study based on synchrotron data  

SciTech Connect (OSTI)

While microelectronic devices are frequently characterized with surface-sensitive techniques having nanometer resolution, interconnections used in 3D integration require 3D imaging with high penetration depth and deep sub-micrometer spatial resolution. X-ray tomography is well adapted to this situation. In this context, the purpose of this study is to assess a versatile and turn-key tomographic system allowing for 3D x-ray nanotomography of copper pillars. The tomography tool uses the thin electron beam of a scanning electron microscope (SEM) to provoke x-ray emission from specific metallic targets. Then, radiographs are recorded while the sample rotates in a conventional cone beam tomography scheme that ends up with 3D reconstructions of the pillar. Starting from copper pillars data, collected at the European Synchrotron Radiation Facility, we build a 3D numerical model of a copper pillar, paying particular attention to intermetallics. This model is then used to simulate physical radiographs of the pillar using the geometry of the SEM-hosted x-ray tomography system. Eventually, data are reconstructed and it is shown that the system makes it possible the quantification of 3D intermetallics volume in copper pillars. The paper also includes a prospective discussion about resolution issues.

Martin, N.; Bertheau, J.; Charbonnier, J.; Hugonnard, P.; Lorut, F. [ST Microelectronics, 850 Rue Jean Monnet, 38920 Crolles (France); Bleuet, P.; Tabary, J. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Laloum, D. [ST Microelectronics, 850 Rue Jean Monnet, 38920 Crolles (France); CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France)

2013-02-15T23:59:59.000Z

160

Electron line shape and transmission function of the KATRIN monitor spectrometer  

SciTech Connect (OSTI)

Knowledge of the neutrino mass is of particular interest in modern neutrino physics. Besides the neutrinoless double beta decay and cosmological observation information about the neutrino mass is obtained from single beta decay by observing the shape of the electron spectrum near the endpoint. The KATRIN ? decay experiment aims to push the limit on the effective electron antineutrino mass down to 0.2 eV/c{sup 2}. To reach this sensitivity several systematic effects have to be under control. One of them is the fluctuations of the absolute energy scale, which therefore has to be continuously monitored at very high precision. This paper shortly describes KATRIN, the technique for continuous monitoring of the absolute energy scale and recent improvements in analysis of the monitoring data.

Slezák, M. [Faculty of Mathematics and Physics, Charles University, Ke Karlovu 3, 12116 Prague, Czech Republic and Nuclear Physics Institute, Academy of Sciences of the Czech Republic, Hlavní 130, 25068 ?ež (Czech Republic)

2013-12-30T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

A transmission electron microscopy investigation of inverse melting in Nb{sub 45}Cr{sub 55}  

SciTech Connect (OSTI)

In inverse melting, a supersaturated crystalline phase transforms polymorphously under heat treatment to the amorphous state. Inverse melting of body-centered cubic (bcc) Nb{sub 45}Cr{sub 55} is studied using transmission electron microscopy (TEM) and high resolution TEM (HRTEM). The crystalline to amorphous transformation is heterogeneous, initiating at the bcc grain boundaries. HRTEM reveals 2-3 nm domains with medium range order (MRO) in the amorphous phase. Preferred orientation of MRO domains is found on a scale corresponding to the precursor bcc grain size. Using HRTEM and calorimetry, MRO development in cosputtered Nb{sub 45}Cr{sub 55} films is characterized and compared to that in the amorphous phase produced by inverse melting. {copyright} {ital 1997 Materials Research Society.}

Sinkler, W.; Michaelsen, C.; Bormann, R. [Institute for Materials Research, GKSS Research Center, 21502 Geesthacht (Germany)

1997-07-01T23:59:59.000Z

162

Transmission electron microscopy characterization of laser-clad iron-based alloy on Al-Si alloy  

SciTech Connect (OSTI)

Microstructure characterization is important for controlling the quality of laser cladding. In the present work, a detailed microstructure characterization by transmission electron microscopy was carried out on the iron-based alloy laser-clad on Al-Si alloy and an unambiguous identification of phases in the coating was accomplished. It was found that there is austenite, Cr{sub 7}C{sub 3} and Cr{sub 23}C{sub 6} in the clad region; {alpha}-Al, NiAl{sub 3}, Fe{sub 2}Al{sub 5} and FeAl{sub 2} in the interface region; and {alpha}-Al and silicon in the heat-affected region. A brief discussion was given for their existence based on both kinetic and thermodynamic principles.

Mei, Z. [State Key Lab of Die and Mould Technology, Huazhong University of Science and Technology, Wuhan 430074 (China)]. E-mail: mikemei_99@yahoo.com; Wang, W.Y. [Institute of Materials Science and Engineering, Henan University of Science and Technology, Luoyang 471003 (China); Wang, A.H. [State Key Lab of Die and Mould Technology, Huazhong University of Science and Technology, Wuhan 430074 (China)

2006-04-15T23:59:59.000Z

163

Golden rule kinetics of transfer reactions in condensed phase: The microscopic model of electron transfer reactions in disordered solid matrices  

SciTech Connect (OSTI)

The algorithm for a theoretical calculation of transfer reaction rates for light quantum particles (i.e., the electron and H-atom transfers) in non-polar solid matrices is formulated and justified. The mechanism postulated involves a local mode (an either intra- or inter-molecular one) serving as a mediator which accomplishes the energy exchange between the reacting high-frequency quantum mode and the phonon modes belonging to the environment. This approach uses as a background the Fermi golden rule beyond the usually applied spin-boson approximation. The dynamical treatment rests on the one-dimensional version of the standard quantum relaxation equation for the reduced density matrix, which describes the frequency fluctuation spectrum for the local mode under consideration. The temperature dependence of a reaction rate is controlled by the dimensionless parameter ?{sub 0}=??{sub 0}/k{sub B}T where ?{sub 0} is the frequency of the local mode and T is the temperature. The realization of the computational scheme is different for the high/intermediate (?{sub 0} < 1 ? 3) and for low (?{sub 0}? 1) temperature ranges. For the first (quasi-classical) kinetic regime, the Redfield approximation to the solution of the relaxation equation proved to be sufficient and efficient in practical applications. The study of the essentially quantum-mechanical low-temperature kinetic regime in its asymptotic limit requires the implementation of the exact relaxation equation. The coherent mechanism providing a non-vanishing reaction rate has been revealed when T? 0. An accurate computational methodology for the cross-over kinetic regime needs a further elaboration. The original model of the hopping mechanism for electronic conduction in photosensitive organic materials is considered, based on the above techniques. The electron transfer (ET) in active centers of such systems proceeds via local intra- and intermolecular modes. The active modes, as a rule, operate beyond the kinetic regimes, which are usually postulated in the existing theories of the ET. Our alternative dynamic ET model for local modes immersed in the continuum harmonic medium is formulated for both classical and quantum regimes, and accounts explicitly for the mode/medium interaction. The kinetics of the energy exchange between the local ET subsystem and the surrounding environment essentially determine the total ET rate. The efficient computer code for rate computations is elaborated on. The computations are available for a wide range of system parameters, such as the temperature, external field, local mode frequency, and characteristics of mode/medium interaction. The relation of the present approach to the Marcus ET theory and to the quantum-statistical reaction rate theory [V. G. Levich and R. R. Dogonadze, Dokl. Akad. Nauk SSSR, Ser. Fiz. Khim. 124, 213 (1959); J. Ulstrup, Charge Transfer in Condensed Media (Springer, Berlin, 1979); M. Bixon and J. Jortner, Adv. Chem. Phys. 106, 35 (1999)] underlying it is discussed and illustrated by the results of computations for practically important target systems.

Basilevsky, M. V.; Mitina, E. A. [Photochemistry Center, Russian Academy of Sciences, 7a, Novatorov ul., Moscow (Russian Federation)] [Photochemistry Center, Russian Academy of Sciences, 7a, Novatorov ul., Moscow (Russian Federation); Odinokov, A. V. [Photochemistry Center, Russian Academy of Sciences, 7a, Novatorov ul., Moscow (Russian Federation) [Photochemistry Center, Russian Academy of Sciences, 7a, Novatorov ul., Moscow (Russian Federation); National Research Nuclear University “MEPhI,” 31, Kashirskoye shosse, Moscow (Russian Federation); Titov, S. V. [Karpov Institute of Physical Chemistry, 3-1/12, Building 6, Obuha pereulok, Moscow (Russian Federation)] [Karpov Institute of Physical Chemistry, 3-1/12, Building 6, Obuha pereulok, Moscow (Russian Federation)

2013-12-21T23:59:59.000Z

164

High-power microwave transmission systems for electron-cyclotron-resonance plasma heating  

SciTech Connect (OSTI)

This progress report is for the sixth year of a grant from the US Department of Energy for the design, development, and fabrication of ECRH transmission and mode conversion systems to transport microwave power from a gyrotron to a magnetically confined plasma. The design and low-power testing of new and improved components for such systems and development of underlying theory is the focus of this project. Devising and improving component testing and diagnostic techniques is also an important part of this effort. The development of possible designs for sections of gyrotrons themselves, such as tapers or Vlasov-type launchers, in support of the Varian gyrotron development program is also considered when appropriate. We also provide support to other groups working on ECR heating of magnetically confined plasmas such as the groups at General Atomics, the University of Texas at Austin, and Lawrence Livermore National Laboratory. During the last year, we designed and had fabricated a two-dimensional Vlasov antenna system for a 110 GHz TE{sub 15,2} mode gyrotron for possible use at General Atomics. The system included the launcher section, a visor, main reflector, and focusing reflector. Programs to generate the tool-path profiles to cut the General Atomics'' Vlasov components on a milling machine were developed. We have also developed state-of-the art theory and programs for three-dimensional whispering-gallery-mode Vlasov antenna systems. A design for a 110 GHz TE{sub 01}-TE{sub 15,2} mode converter system for cold testing WGM Vlasov antenna systems was developed and is currently being fabricated also.

Vernon, R.J.

1991-08-01T23:59:59.000Z

165

Dynamic imaging with electron microscopy  

ScienceCinema (OSTI)

Livermore researchers have perfected an electron microscope to study fast-evolving material processes and chemical reactions. By applying engineering, microscopy, and laser expertise to the decades-old technology of electron microscopy, the dynamic transmission electron microscope (DTEM) team has developed a technique that can capture images of phenomena that are both very small and very fast. DTEM uses a precisely timed laser pulse to achieve a short but intense electron beam for imaging. When synchronized with a dynamic event in the microscope's field of view, DTEM allows scientists to record and measure material changes in action. A new movie-mode capability, which earned a 2013 R&D 100 Award from R&D Magazine, uses up to nine laser pulses to sequentially capture fast, irreversible, even one-of-a-kind material changes at the nanometer scale. DTEM projects are advancing basic and applied materials research, including such areas as nanostructure growth, phase transformations, and chemical reactions.

Campbell, Geoffrey; McKeown, Joe; Santala, Melissa

2014-05-30T23:59:59.000Z

166

Dynamic imaging with electron microscopy  

SciTech Connect (OSTI)

Livermore researchers have perfected an electron microscope to study fast-evolving material processes and chemical reactions. By applying engineering, microscopy, and laser expertise to the decades-old technology of electron microscopy, the dynamic transmission electron microscope (DTEM) team has developed a technique that can capture images of phenomena that are both very small and very fast. DTEM uses a precisely timed laser pulse to achieve a short but intense electron beam for imaging. When synchronized with a dynamic event in the microscope's field of view, DTEM allows scientists to record and measure material changes in action. A new movie-mode capability, which earned a 2013 R&D 100 Award from R&D Magazine, uses up to nine laser pulses to sequentially capture fast, irreversible, even one-of-a-kind material changes at the nanometer scale. DTEM projects are advancing basic and applied materials research, including such areas as nanostructure growth, phase transformations, and chemical reactions.

Campbell, Geoffrey; McKeown, Joe; Santala, Melissa

2014-02-20T23:59:59.000Z

167

Probing the Degradation Mechanisms in Electrolyte Solutions for Li-ion Batteries by In-Situ Transmission Electron Microscopy  

SciTech Connect (OSTI)

One of the goals in the development of new battery technologies is to find new electrolytes with increased electrochemical stability. In-situ (scanning) transmission electron microscopy ((S)TEM) using an electrochemical fluid cell provides the ability to rapidly and directly characterize electrode/electrolyte interfacial reactions under battery relevant electrochemical conditions. Furthermore, as the electron beam itself causes a localized electrochemical reaction when it interacts with the electrolyte, the breakdown products that occur during the first stages of battery operation can potentially be simulated and characterized using a straightforward in-situ liquid stage (without electrochemical biasing capabilities). In this paper, we have studied the breakdown of a range of inorganic/salt complexes that are used in state-of-the-art Li-ion battery systems. The results of the in-situ (S)TEM experiments matches with previous stability tests performed during battery operation and the breakdown products and mechanisms are also consistent with known mechanisms. This analysis indicates that in-situ liquid stage (S)TEM observations can be used to directly test new electrolyte designs and provide structural insights into the origin of the solid electrolyte interphase (SEI) formation mechanism.

Abellan Baeza, Patricia; Mehdi, Beata L.; Parent, Lucas R.; Gu, Meng; Park, Chiwoo; Xu, Wu; Zhang, Yaohui; Arslan, Ilke; Zhang, Jiguang; Wang, Chong M.; Evans, James E.; Browning, Nigel D.

2014-02-21T23:59:59.000Z

168

Thermodynamic Prediction of Compositional Phases Confirmed by Transmission Electron Microscopy on Tantalum-Based Alloy Weldments  

SciTech Connect (OSTI)

Tantalum alloys have been used by the U.S. Department of Energy as structural alloys for radioisotope based thermal to electrical power systems since the 1960s. Tantalum alloys are attractive for high temperature structural applications due to their high melting point, excellent formability, good thermal conductivity, good ductility (even at low temperatures), corrosion resistance, and weldability. Tantalum alloys have demonstrated sufficient high-temperature toughness to survive prolonged exposure to the radioisotope power-system working environment. Typically, the fabrication of power systems requires the welding of various components including the structural members made of tantalum alloys. Issues such as thermodynamics, lattice structure, weld pool dynamics, material purity and contamination, and welding atmosphere purity all potentially confound the understanding of the differences between the weldment properties of the different tantalum-based alloys. The objective of this paper is to outline the thermodynamically favorable material phases in tantalum alloys, with and without small amounts of hafnium, during and following solidification, based on the results derived from the FactSage(c) Integrated Thermodynamic Databank. In addition, Transition Electron Microscopy (TEM) data will show for the first time, the changes occurring in the HfC before and after welding, and the data will elucidate the role HfC plays in pinning grain boundaries.

Moddeman, William E.; Birkbeck, Janine C. [BWXT Pantex, Amarillo, Texas 79120-0020 (United States); Barklay, Chadwick D.; Kramer, Daniel P. [University of Dayton Research Institute, Dayton OH 45469-0102 (United States); Miller, Roger G.; Allard, Lawrence F. [Oak Ridge National Laboratory, Oak Ridge, TN 37831-6064 (United States)

2007-01-30T23:59:59.000Z

169

Electronic  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

contribution contribution to friction on GaAs: An atomic force microscope study Yabing Qi, 1,2 J. Y. Park, 2 B. L. M. Hendriksen, 2 D. F. Ogletree, 2 and M. Salmeron 2,3 1 Applied Science and Technology Graduate Group, University of California, Berkeley, California 94720, USA 2 Materials Sciences Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720, USA 3 Department of Materials Sciences and Engineering, University of California, Berkeley, California 94720, USA ͑Received 23 January 2008; revised manuscript received 11 April 2008; published 7 May 2008͒ The electronic contribution to friction at semiconductor surfaces was investigated by using a Pt-coated tip with 50 nm radius in an atomic force microscope sliding against an n-type GaAs͑100͒ substrate. The GaAs surface was covered by an approximately 1 nm thick oxide layer. Charge accumulation

170

Transmission electron microscopy and atom probe specimen preparation from mechanically alloyed powder using the focused ion-beam lift-out technique  

Science Journals Connector (OSTI)

......prepared by consolidation of amorphous powders in the supercooled liquid region. Intermetallics (2004) 12:1109-1113. 6 Overwijk M H F , Van Den Heuvel F C, Bulle-Lieuwma C W T. Novel scheme for the preparation of transmission electron microscopy specimens......

Pyuck-Pa Choi; Young-Soon Kwon; Ji-Soon Kim; Tala?at Al-Kassab

2007-04-01T23:59:59.000Z

171

IEEE TRANSACTIONS ON ELECTRON DEVICES, VOL. 53, NO. 2, FEBRUARY 2006 235 De-Embedding Transmission Line Measurements for  

E-Print Network [OSTI]

of parasitic structures from transmission line measurements is presented and applied to microstrip lines technologies, integrated circuits, interconnect, losses, microstrip lines, slotted ground planes, transmission comparable to on-chip component dimensions. Hence, transmission lines play an in- creasingly vital role

Voinigescu, Sorin Petre

172

Abstract--The increase in use of power electronics in transmission and distribution applications is the driving  

E-Print Network [OSTI]

is the driving force for development of high power devices. Utility applications like FACTS and HVDC require cost and compared for SiC and Si devices. These loss models are integrated with an HVDC transmission system to study of the systems. High Voltage DC (HVDC) transmission and Flexible AC Transmission Systems (FACTS) are the widely

Tolbert, Leon M.

173

E-Print Network 3.0 - automated microscopic characterization...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

characterization problems with the help... in the electron optics, alignment and optimization of electron microscopes. Students will have plenty... of opportunities for hands-on...

174

QUANTITATIVE ELECTRON HOLOGRAPHY OF BIASED SEMICONDUCTOR DEVICES  

E-Print Network [OSTI]

ion beam (FIB) milling (Fig. 1b). Figure 2a shows a 200 kV holographic phase image obtained from transmission electron microscope (FEGTEM)2 . The technique relies on the use of an electrostatic biprism (eg to result from the presence of an electrically dead layer that runs around its entire surface. A line trace

Dunin-Borkowski, Rafal E.

175

Development of a Silicon Based Electron Beam Transmission Window for Use in a KrF Excimer Laser System  

SciTech Connect (OSTI)

The Princeton Plasma Physics Laboratory (PPPL), in collaboration with the Naval Research Laboratory (NRL), is currently investigating various novel materials (single crystal silicon, <100>, <110> and <111>) for use as electron-beam transmission windows in a KrF excimer laser system. The primary function of the window is to isolate the active medium (excimer gas) from the excitation mechanism (field-emission diodes). Chosen window geometry must accommodate electron energy transfer greater than 80% (750 keV), while maintaining structural integrity during mechanical load (1.3 to 2.0 atm base pressure differential, approximate 0.5 atm cyclic pressure amplitude, 5 Hz repetition rate) and thermal load across the entire hibachi area (approximate 0.9 W {center_dot} cm superscript ''-2''). In addition, the window must be chemically resistant to attack by fluorine free-radicals (hydrofluoric acid, secondary). In accordance with these structural, functional, and operational parameters, a 22.4 mm square silicon prototype window, coated with 500 nm thin-film silicon nitride (Si{sub 3}N{sub 4}), has been fabricated. The window consists of 81 square panes with a thickness of 0.019 mm {+-} 0.001 mm. Stiffened (orthogonal) sections are 0.065 mm in width and 0.500 mm thick (approximate). Appended drawing (Figure 1) depicts the window configuration. Assessment of silicon (and silicon nitride) material properties and CAD modeling and analysis of the window design suggest that silicon may be a viable solution to inherent parameters and constraints.

C.A. Gentile; H.M. Fan; J.W. Hartfield; R.J. Hawryluk; F. Hegeler; P.J. Heitzenroeder; C.H. Jun; L.P. Ku; P.H. LaMarche; M.C. Myers; J.J. Parker; R.F. Parsells; M. Payen; S. Raftopoulos; J.D. Sethian

2002-11-21T23:59:59.000Z

176

Separating strain from composition in unit cell parameter maps obtained from aberration corrected high resolution transmission electron microscopy imaging  

SciTech Connect (OSTI)

Based on the evaluation of lattice parameter maps in aberration corrected high resolution transmission electron microscopy images, we propose a simple method that allows quantifying the composition and disorder of a semiconductor alloy at the unit cell scale with high accuracy. This is realized by considering, next to the out-of-plane, also the in-plane lattice parameter component allowing to separate the chemical composition from the strain field. Considering only the out-of-plane lattice parameter component not only yields large deviations from the true local alloy content but also carries the risk of identifying false ordering phenomena like formations of chains or platelets. Our method is demonstrated on image simulations of relaxed supercells, as well as on experimental images of an In{sub 0.20}Ga{sub 0.80}N quantum well. Principally, our approach is applicable to all epitaxially strained compounds in the form of quantum wells, free standing islands, quantum dots, or wires.

Schulz, T.; Remmele, T.; Korytov, M.; Markurt, T.; Albrecht, M. [Leibniz-Institut für Kristallzüchtung, Max-Born-Straße 2, 12489 Berlin (Germany); Duff, A.; Lymperakis, L.; Neugebauer, J. [Max-Planck-Institut für Eisenforschung, Max-Planck-Straße 1, 40237 Düsseldorf (Germany); Chèze, C. [TopGaN Sp. z o.o., Sokolowska 29/37, 01-142 Warsaw (Poland); Skierbiszewski, C. [TopGaN Sp. z o.o., Sokolowska 29/37, 01-142 Warsaw (Poland); Institute of High Pressure Physics, Polish Academy of Sciences, Sokolowska 29/37, 01-142 Warsaw (Poland)

2014-01-21T23:59:59.000Z

177

Atomic-resolution study of polarity reversal in GaSb grown on Si by scanning transmission electron microscopy  

SciTech Connect (OSTI)

The atomic-resolved reversal of the polarity across an antiphase boundary (APB) was observed in GaSb films grown on Si by high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM). The investigation of the interface structure at the origin of the APB reveals that coalescence of two domains with Ga-prelayer and Sb-prelayer causes the sublattice reversal. The local strain and lattice rotation distributions of the APB, attributed to the discordant bonding length at the APB with the surrounding GaSb lattice, were further studied using the geometric phase analysis technique. The crystallographic characteristics of the APBs and their interaction with other planar defects were observed with HAADF-STEM. The quantitative agreement between experimental and simulated images confirms the observed polarities in the acquired HAADF-STEM data. The self-annihilation mechanism of the APBs is addressed based on the rotation induced by anti-site bonds and APBs' faceting.

Hosseini Vajargah, S.; Woo, S. Y.; Botton, G. A. [Department of Materials Science and Engineering, McMaster University, Hamilton, Ontario L8S 4L7 (Canada); Brockhouse Institute for Material Research, McMaster University, Hamilton, Ontario L8S 4M1 (Canada); Canadian Centre for Electron Microscopy, McMaster University, Hamilton, Ontario L8S 4M1 (Canada); Ghanad-Tavakoli, S. [Centre for Emerging Device Technologies, McMaster University, Hamilton, Ontario L8S 4L7 (Canada); Kleiman, R. N.; Preston, J. S. [Brockhouse Institute for Material Research, McMaster University, Hamilton, Ontario L8S 4M1 (Canada); Centre for Emerging Device Technologies, McMaster University, Hamilton, Ontario L8S 4L7 (Canada); Department of Engineering Physics, McMaster University, Hamilton, Ontario L8S 4L7 (Canada)

2012-11-01T23:59:59.000Z

178

Electron  

Science Journals Connector (OSTI)

Absolute grand total cross sections (TCSs) for electron-disilane (Si2H6) scattering have been measured over the energy range from 1 to 370 eV in a linear transmission experiment. The low-energy TCS is dominated by a broad resonant-like enhancement. In the region of the maximum the present grand TCS values appeared to be distinctly lower than previously reported integral elastic cross section data. A comparison of total electron scattering cross sections for the two simplest silicon hydrides and relevant hydrocarbons is given.

Czeslaw Szmytkowski; Pawel Mozejko; Grzegorz Kasperski

2001-01-01T23:59:59.000Z

179

Solid state optical microscope  

DOE Patents [OSTI]

A solid state optical microscope wherein wide-field and high-resolution images of an object are produced at a rapid rate by utilizing conventional optics with a charge-coupled photodiode array. A galvanometer scanning mirror, for scanning in one of two orthogonal directions is provided, while the charge-coupled photodiode array scans in the other orthogonal direction. Illumination light from the object is incident upon the photodiodes, creating packets of electrons (signals) which are representative of the illuminated object. The signals are then processed, stored in a memory, and finally displayed as a video signal. 2 figs.

Young, I.T.

1983-08-09T23:59:59.000Z

180

Solid state optical microscope  

DOE Patents [OSTI]

A solid state optical microscope wherein wide-field and high-resolution images of an object are produced at a rapid rate by utilizing conventional optics with a charge-coupled photodiode array. A galvanometer scanning mirror, for scanning in one of two orthogonal directions is provided, while the charge-coupled photodiode array scans in the other orthogonal direction. Illumination light from the object is incident upon the photodiodes, creating packets of electrons (signals) which are representative of the illuminated object. The signals are then processed, stored in a memory, and finally displayed as a video signal.

Young, Ian T. (Pleasanton, CA)

1983-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Los Alamos: MST-MTM: EML: Electron Microscopy Laboratory  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Electron Microscopy Laboratory, MST-6 Electron Microscopy Laboratory, MST-6 MST-6 Home Home In the MSL FEI Tecnai F30 Analytical TEM/STEM JEOL 6300FXV High Resolution SEM JEOL 3000F High Resolution Transmission Electron Microscope Philips XL30 F Scanning Electron Microscope & Orientation Imaging System Phillips CM30 Transmission Electron Microscope In the Sigma Building JEOL 840 EPMA with Wavelength Dispersive Spectroscopy FEI Strata DB235 FIB/SEM FEI XL30 Environmental Scanning Electron Microscope & Orientation Imaging System CONTACTS Bob Field 665.3938 Pat Dickerson 665.3036 Rob Dickerson 667.6337 Rod McCabe 606.1649 The Electron Microscopy Laboratory's Capabilities The Electron Microscopy Laboratory's Capabilities The Electron Microscopy Laboratory (EML) is part of MST-6, the Materials Technology - Metallurgy Group within the Materials Science and Technology Division at Los Alamos National Laboratory. It is a facility dedicated to the characterization of materials primarily through imaging, chemical, and crystallographic analyses of material microstructures with several electron and ion beam instruments. Accessory characterization techniques and equipment include energy dispersive x-ray analysis (EDS), wavelength dispersive x-ray analysis (WDS), electron backscatter diffraction (EBSD) and orientation imaging microscopy (OIM), and electron energy loss spectroscopy (EELS).

182

Raman and electron microscopic studies of Si{sub 1-x}Ge{sub x} alloy nanowires grown by chemical vapor deposition  

SciTech Connect (OSTI)

Si{sub 1-x}Ge{sub x} alloy nanowires (SiGeNWs) were grown by Au-catalyzed chemical vapor deposition and studied by Raman spectroscopy, transmission electron microscopy (TEM), and energy-dispersive x-ray spectroscopy (EDS) in TEM (TEM-EDS). The relationship between the growth parameters and the structure of the SiGeNWs was clarified by systematically changing the growth conditions over a wide range. Raman and TEM-EDS results demonstrated that the SiGeNWs consist of a lower Ge composition core and a higher Ge composition shell epitaxially grown on the surface of the core. The effects of oxidation on the structure of the SiGeNWs were studied. It was found that oxidation leads to segregation of the Ge atoms at the interface between the SiGeNWs and SiO{sub 2}, which in turn results in a large inhomogeneity in Ge composition. Oxidation at a very low rate in a diluted oxygen gas atmosphere is required to avoid the formation of Ge particles and minimize the inhomogeneity.

Kawashima, Takahiro; Imamura, Goh; Fujii, Minoru; Hayashi, Shinji; Saitoh, Tohru; Komori, Kazunori [Advanced Devices Development Center, Matsushita Electric Industrial Co., Ltd., 3-1-1 Yagumo-Nakamachi, Moriguchi, Osaka 570-8501 (Japan); Department of Electrical and Electronic Engineering, Graduate School of Engineering, Kobe University, 1-1 Rokkodai, Nada, Kobe 657-8501 (Japan); Image Devices Development Center, Matsushita Electric Industrial Co., Ltd., 3-1-1 Yagumo-Nakamachi, Moriguchi, Osaka 570-8501 (Japan)

2007-12-15T23:59:59.000Z

183

FTIR Microscope | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

FTIR Microscope FTIR Microscope Two Bruker Fourier Transform Infrared (FTIR) spectrometers (IFS66 and IFS66V) with visible, near-, mid- and far-infrared (IR) capabilities are...

184

Development of the doppler electron velocimeter: theory.  

SciTech Connect (OSTI)

Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

Reu, Phillip L.

2007-03-01T23:59:59.000Z

185

Spin microscope based on optically detected magnetic resonance  

DOE Patents [OSTI]

The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

Berman, Gennady P. (Los Alamos, NM); Chernobrod, Boris M. (Los Alamos, NM)

2007-12-11T23:59:59.000Z

186

Spin microscope based on optically detected magnetic resonance  

DOE Patents [OSTI]

The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

Berman, Gennady P. (Los Alamos, NM); Chernobrod, Boris M. (Los Alamos, NM)

2010-06-29T23:59:59.000Z

187

Spin microscope based on optically detected magnetic resonance  

DOE Patents [OSTI]

The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of impaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

Berman, Gennady P. (Los Alamos, NM); Chernobrod, Boris M. (Los Alamos, NM)

2009-11-10T23:59:59.000Z

188

Spin microscope based on optically detected magnetic resonance  

DOE Patents [OSTI]

The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

Berman, Gennady P. (Los Alamos, NM); Chernobrod, Boris M. (Los Alamos, NM)

2009-10-27T23:59:59.000Z

189

Towards the quantitative analysis of the electron holographic phase images of electrically biased metal tips  

E-Print Network [OSTI]

were acquired at an accelerating voltage of 300 kV using an FEI Titan field emission gun TEM equipped be carried out quantitatively using off-axis electron holography in the transmission electron microscope (TEM by considering the electrostatic potential generated by a line of charges with a density that increases linearly

Dunin-Borkowski, Rafal E.

190

Magnetic interactions within patterned cobalt nanostructures using off-axis electron holography  

E-Print Network [OSTI]

charge-coupled device camera.3 An additional Lorentz minilens Cs 8 m and 1.2 nm line resolution at 200 kV at 200 kV using a Philips CM200-FEG TEM equipped with a field- emission electron source, an electrostatic holography2 in the transmission electron microscope TEM to investigate the magnetic properties of patterned

Dunin-Borkowski, Rafal E.

191

Investigation of aged organic solar cell stacks by cross-sectional transmission electron microscopy coupled with elemental analysis  

Science Journals Connector (OSTI)

Polymer solar cells are of great interest as candidates for...61...-butyric acid methyl ester (P3HT and PCBM, respectively). Phase segregation of the blend has been extensively investigated by transmission electr...

P. Favia; E. Voroshazi; P. Heremans; H. Bender

2013-04-01T23:59:59.000Z

192

STRUCTURAL AND CHEMICAL STUDIES ON CdTe/CdS THIN FILM SOLAR CELLS WITH ANALYTICAL TRANSMISSION ELECTRON MICROSCOPY  

E-Print Network [OSTI]

STRUCTURAL AND CHEMICAL STUDIES ON CdTe/CdS THIN FILM SOLAR CELLS WITH ANALYTICAL TRANSMISSION, A. N. Tiwari Thin Film Physics Group, Laboratory for Solid State Physics, Technopark ETH-Building, Technoparkstr. 1, CH-8005 Zurich, Switzerland ABSTRACT: CdTe/CdS thin £lm solar cells have been grown by closed

Romeo, Alessandro

193

Spin torque and heating effects in current-induced domain wall motion probed by transmission electron microscopy  

E-Print Network [OSTI]

Spin torque and heating effects in current-induced domain wall motion probed by transmission- ternative to the use of conventional external magnetic fields, therefore opening up a route for simple device fabrication, where no field-generating strip lines are necessary. While current-induced domain

Dunin-Borkowski, Rafal E.

194

Transmission electron microscopy and Monte Carlo simulations of ordering in Au-Cu clusters produced in a laser vaporization source  

Science Journals Connector (OSTI)

Au-Cu bimetallic alloy clusters are produced in a laser vaporization source starting from Au-Cu alloy targets with different stoichiometric compositions. The clusters are deposited on two different substrates—amorphous carbon and crystalline MgO—and are characterized by electron diffraction and high-resolution electron microscopy. The experiments show that the overall chemical composition in the clusters is the same as the chemical composition of the target material; but the crystal structure of the Au-Cu alloy clusters differs from their known bulk crystal structure. Electron microscopy experiments provide evidence that no chemical ordering exists between Au and Cu atoms and that the clusters are solid solutions. Monte Carlo simulations using the second moment tight-binding approximation, however, predict Cu3Au clusters ordered in the core but with a disordered mantle. The possible origins of the differences between experiment and Monte Carlo simulations are discussed.

B. Pauwels; G. Van Tendeloo; E. Zhurkin; M. Hou; G. Verschoren; L. Theil Kuhn; W. Bouwen; P. Lievens

2001-03-27T23:59:59.000Z

195

Helium Ion Microscope | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

other characterization capabilities. User Portal Name: Helium Ion Microscope Instrument ID: 34104 Availability: 10 hours a day, 5 days a week Facility: Quiet Wing Quick Specs...

196

Soft x-ray laser microscope  

SciTech Connect (OSTI)

The program consisted of two phases (Phase I and Phase II). The goal of the Phase I (first year program) was to design and construct the Soft X-ray Laser Contact Microscope. Such microscope was constructed and adapted to PPL's 18.2nm soft X-ray Laser (SXL), which in turn was modified and prepared for microscopy experiments. Investigation of the photoresist response to 18.2nm laser radiation and transmissivity of 0.1m thick silicion-nitride (Si[sub 3]N[sub 4]) windows were important initial works. The goal of the first year of Phase II was to construct X-ray contact microscope in combination with existing optical phase microscope, already used by biologists. In the second year of Phase II study of dehydrated Horeseshoe Crab and Hela cancer cells were performed with COXRALM. Also during Phase II, the Imaging X-Ray Laser Microscope (IXRALM) was designed and constructed. This paper describes the development of each of the microscopes and their application for research.

Suckewer, P.I.

1990-10-01T23:59:59.000Z

197

A transmission electron microscopy study of the deformation behavior underneath nanoindents in nano-scale Al-TiN multilayered composites  

SciTech Connect (OSTI)

Nano-scale multilayered Al-TiN composites were deposited with DC magnetron sputtering technique in two different layer thickness ratios - Al:TiN = 1:1 and Al:TiN = 9:1. The Al layer thickness varied from 2 nm to 450 nm. The hardness of the samples was tested by nanoindentation using a Berkovich tip. Cross-sectional Transmission Electron Microscopy (TEM) was carried out on samples extracted with Focused Ion Beam (FIB) from below the nanoindents. This paper presents the results of the hardness tests in the Al-TiN multilayers with the two different thickness ratios and the observations from the cross-sectional TEM studies of the regions underneath the indents. These studies showed remarkable strength in the multilayers, as well as some very interesting deformation behavior in the TiN layers at extremely small length scales, where the hard TiN layers undergo co-deformation with the Al layers.

Bhattacharyya, Dhriti [Los Alamos National Laboratory; Mara, Nathan A [Los Alamos National Laboratory; Dickerson, Patricia O [Los Alamos National Laboratory; Misra, Amit [Los Alamos National Laboratory; Hoagland, R G [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

198

Quantitative Examination of Reverse-Biased Semiconductor Devices using Off-Axis Electron Holography  

E-Print Network [OSTI]

-machined in the cleaved samples using focused ion beam (FIB) milling (Fig. 1b). Figure 2a shows a 200 kV holographic phase using a field emission gun transmission electron microscope (FEGTEM) [1]. The technique uses layer that runs around its entire surface. A line trace showing the phase profile across the junction

Dunin-Borkowski, Rafal E.

199

SunShot Initiative: Transmission Grid Integration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission Grid Integration to Transmission Grid Integration to someone by E-mail Share SunShot Initiative: Transmission Grid Integration on Facebook Tweet about SunShot Initiative: Transmission Grid Integration on Twitter Bookmark SunShot Initiative: Transmission Grid Integration on Google Bookmark SunShot Initiative: Transmission Grid Integration on Delicious Rank SunShot Initiative: Transmission Grid Integration on Digg Find More places to share SunShot Initiative: Transmission Grid Integration on AddThis.com... Concentrating Solar Power Photovoltaics Systems Integration Research, Development, & Demonstration Distribution Grid Integration Transmission Grid Integration Solar Resource Assessment Technology Validation Power Electronics & Balance of System Hardware Technologies Competitive Awards

200

Solid-state optical microscope  

DOE Patents [OSTI]

A solid state optical microscope is described wherein wide-field and high-resolution images of an object are produced at a rapid rate by utilizing conventional optics with a charge-coupled photodiode array. Means for scanning in one of two orthogonal directions are provided, while the charge-coupled photodiode array scans in the other orthogonal direction. Illumination light from the object is incident upon the photodiodes, creating packets of electrons (signals) which are representative of the illuminated object. The signals are then processed, stored in a memory, and finally displayed as a video signal.

Young, I.T.

1981-01-07T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Astronomy by microscope  

Science Journals Connector (OSTI)

......August 2009 research-article Features Astronomy by microscope Monica M Grady reviews the astronomy revealed in samples of solar system material...of the Natural History Museum, London. Astronomy is the study of stars (and galaxies......

Monica M Grady

2009-08-01T23:59:59.000Z

202

Microscope collision protection apparatus  

DOE Patents [OSTI]

A microscope collision protection apparatus for a remote control microscope which protects the optical and associated components from damage in the event of an uncontrolled collision with a specimen, regardless of the specimen size or shape. In a preferred embodiment, the apparatus includes a counterbalanced slide for mounting the microscope's optical components. This slide replaces the rigid mounts on conventional upright microscopes with a precision ball bearing slide. As the specimen contacts an optical component, the contacting force will move the slide and the optical components mounted thereon. This movement will protect the optical and associated components from damage as the movement causes a limit switch to be actuated, thereby stopping all motors responsible for the collision.

DeNure, Charles R. (Pocatello, ID)

2001-10-23T23:59:59.000Z

203

Uranium-contaminated soils: Ultramicrotomy and electron beam analysis  

SciTech Connect (OSTI)

Uranium contaminated soils from the Fernald Operation Site, Ohio, have been examined by a combination of optical microscopy, scanning electron microscopy with backscattered electron detection (SEM/BSE), and analytical electron microscopy (AEM). A method is described for preparing of transmission electron microscopy (TEM) thin sections by ultramicrotomy. By using these thin sections, SEM and TEM images can be compared directly. Uranium was found in iron oxides, silicates (soddyite), phosphates (autunites), and fluorite. Little uranium was associated with clays. The distribution of uranium phases was found to be inhomogeneous at the microscopic level.

Buck, E.C.; Dietz, N.L.; Bates, J.K.; Cunnane, J.C.

1994-04-01T23:59:59.000Z

204

Infrared microscope inspection apparatus  

DOE Patents [OSTI]

Apparatus and system for inspecting infrared transparents, such as an array of photovoltaic modules containing silicon solar cells, includes an infrared microscope, at least three sources of infrared light placed around and having their axes intersect the center of the object field and means for sending the reflected light through the microscope. The apparatus is adapted to be mounted on an X-Y translator positioned adjacent the object surface. 4 figs.

Forman, S.E.; Caunt, J.W.

1985-02-26T23:59:59.000Z

205

Infrared microscope inspection apparatus  

DOE Patents [OSTI]

Apparatus and system for inspecting infrared transparents, such as an array of photovoltaic modules containing silicon solar cells, includes an infrared microscope, at least three sources of infrared light placed around and having their axes intersect the center of the object field and means for sending the reflected light through the microscope. The apparatus is adapted to be mounted on an X-Y translator positioned adjacent the object surface.

Forman, Steven E. (Framingham, MA); Caunt, James W. (Concord, MA)

1985-02-26T23:59:59.000Z

206

Structural defects in epitaxial graphene layers synthesized on C-terminated 4H-SiC (0001{sup ¯}) surface—Transmission electron microscopy and density functional theory studies  

SciTech Connect (OSTI)

The principal structural defects in graphene multilayers synthesized on the carbon-terminated face of a 4H-SiC (0001{sup ¯}) substrate were investigated using the high-resolution transmission electron microscopy. The analyzed systems include a wide variety of defected structures such as edge dislocations, rotational multilayers, and grain boundaries. It was shown that graphene layers are composed of grains of the size of several nanometres or larger; they differ in a relative rotation by large angles, close to 30°. The structure of graphene multilayers results from the synthesis on a SiC (0001{sup ¯}) surface, which proceeds via intensive nucleation of new graphene layers that coalesce under various angles creating an immense orientational disorder. Structural defects are associated with a built-in strain resulting from a lattice mismatch between the SiC substrate and the graphene layers. The density functional theory data show that the high-angular disorder of AB stacked bi-layers is not restoring the hexagonal symmetry of the lattice.

Borysiuk, J., E-mail: jolanta.borysiuk@ifpan.edu.pl [Institute of Physics, Polish Academy of Sciences, Al. Lotników 32/46, 02-668 Warsaw (Poland); Faculty of Physics, University of Warsaw, Ho?a 69, 00-681 Warsaw (Poland); So?tys, J.; Piechota, J. [Interdisciplinary Centre for Mathematical and Computational Modelling, University of Warsaw, Pawi?skiego 5a, 02-106 Warsaw (Poland); Krukowski, S. [Interdisciplinary Centre for Mathematical and Computational Modelling, University of Warsaw, Pawi?skiego 5a, 02-106 Warsaw (Poland); Institute of High Pressure Physics, Polish Academy of Sciences, Soko?owska 29/37, 01-142 Warsaw (Poland); Baranowski, J. M. [Faculty of Physics, University of Warsaw, Ho?a 69, 00-681 Warsaw (Poland); Institute of Electronic Materials Technology, Wólczy?ska 133, 01-919 Warsaw (Poland); St?pniewski, R. [Faculty of Physics, University of Warsaw, Ho?a 69, 00-681 Warsaw (Poland)

2014-02-07T23:59:59.000Z

207

Atomic Resolution Coordination Mapping in Ca2FeCoO5 Brownmillerite by Spatially Resolved Electron Energy-Loss Spectroscopy  

Science Journals Connector (OSTI)

Using a combination of high-angle annular dark field scanning transmission electron microscopy and atomically resolved electron energy-loss spectroscopy at high energy resolution in an aberration-corrected electron microscope, we demonstrate the capability of coordination mapping in complex oxides. ... (b) Survey image indicating the area used for octahedral (red) and tetrahedral (blue) data summation (3 pixel width). ... B atoms that have energetic preference for tetrahedral coordination geometry are esp. ...

Stuart Turner; Johan Verbeeck; Farshid Ramezanipour; John E. Greedan; Gustaaf Van Tendeloo; Gianluigi A. Botton

2012-04-25T23:59:59.000Z

208

Polarization-preserving confocal microscope for optical experiments in a dilution refrigerator with high magnetic field  

E-Print Network [OSTI]

We present the design and operation of a fiber-based cryogenic confocal microscope. It is designed as a compact cold-finger that fits inside the bore of a superconducting magnet, and which is a modular unit that can be easily swapped between use in a dilution refrigerator and other cryostats. We aimed at application in quantum optical experiments with electron spins in semiconductors and the design has been optimized for driving with, and detection of optical fields with well-defined polarizations. This was implemented with optical access via a polarization maintaining fiber together with Voigt geometry at the cold finger, which circumvents Faraday rotations in the optical components in high magnetic fields. Our unit is versatile for use in experiments that measure photoluminescence, reflection, or transmission, as we demonstrate with a quantum optical experiment with an ensemble of donor-bound electrons in a thin GaAs film.

Maksym Sladkov; M. P. Bakker; A. U. Chaubal; D. Reuter; A. D. Wieck; C. H. van der Wal

2010-10-09T23:59:59.000Z

209

Polarization-preserving confocal microscope for optical experiments in a dilution refrigerator with high magnetic field  

E-Print Network [OSTI]

We present the design and operation of a fiber-based cryogenic confocal microscope. It is designed as a compact cold-finger that fits inside the bore of a superconducting magnet, and which is a modular unit that can be easily swapped between use in a dilution refrigerator and other cryostats. We aimed at application in quantum optical experiments with electron spins in semiconductors and the design has been optimized for driving with, and detection of optical fields with well-defined polarizations. This was implemented with optical access via a polarization maintaining fiber together with Voigt geometry at the cold finger, which circumvents Faraday rotations in the optical components in high magnetic fields. Our unit is versatile for use in experiments that measure photoluminescence, reflection, or transmission, as we demonstrate with a quantum optical experiment with an ensemble of donor-bound electrons in a thin GaAs film.

Sladkov, Maksym; Chaubal, A U; Reuter, D; Wieck, A D; van der Wal, C H

2010-01-01T23:59:59.000Z

210

Polarization-preserving confocal microscope for optical experiments in a dilution refrigerator with high magnetic field  

Science Journals Connector (OSTI)

We present the design and operation of a fiber-based cryogenic confocal microscope. It is designed as a compact cold-finger that fits inside the bore of a superconducting magnet and which is a modular unit that can be easily swapped between use in a dilution refrigerator and other cryostats. We aimed at application in quantum optical experiments with electron spins in semiconductors and the design has been optimized for driving with and detection of optical fields with well-defined polarizations. This was implemented with optical access via a polarization maintaining fiber together with Voigt geometry at the cold finger which circumvents Faraday rotations in the optical components in high magnetic fields. Our unit is versatile for use in experiments that measure photoluminescence reflection or transmission as we demonstrate with a quantum optical experiment with an ensemble of donor-bound electrons in a thin GaAs film.

Maksym Sladkov; M. P. Bakker; A. U. Chaubal; D. Reuter; A. D. Wieck; C. H. van der Wal

2011-01-01T23:59:59.000Z

211

The Reflecting Microscope  

Science Journals Connector (OSTI)

...INVESTIGATION OF CATADIOPTRIC SCHWARZSCHILD SYSTEMS, JOURNAL OF THE OPTICAL...PHYSIOLOGY 32 : 489 ( 1949 ). SCHWARZSCHILD, K, GESELLSCHAFT WISS MP...USE OF REFLECTING SYSTEMS of mirror-pairs in microscope objectives...0.65 with an aspheric mirror-pair of Schwarzsehild...

Robert C. Mellors

1950-10-06T23:59:59.000Z

212

Direct electron detection in transmission electron microscopy  

E-Print Network [OSTI]

Duttweiler, J. Bouwer, S. Peltier, M. Ellisman, P. Denes, F.J. C. Bouwer, S. T. Peltier, M. Ellisman and N. -H. Xuong (J. C. Bouwer, S. T. Peltier, M. H. Ellisman and N. H.

Jin, Liang

2009-01-01T23:59:59.000Z

213

Direct electron detection in transmission electron microscopy  

E-Print Network [OSTI]

a three-stage thermoelectric cooling module was coupled withbetween the thermoelectric cooling module and the backside

Jin, Liang

2009-01-01T23:59:59.000Z

214

Development of High Voltage Electron Microscope  

Science Journals Connector (OSTI)

......Cockcroft Walton Type High Voltage Generator. O Power Line O Fig. 4...pressure in the tank to the atmospheric pressure by removing freon...pump using liquid nitrogen. Water buffer and liquid nitrogen...base plate of high voltage generator. Four poles stand on this......

Shinjiro KATAGIRI; Hirokazu KIMURA; Susumu OZASA; Kazumi SHIRAISHI

1969-01-01T23:59:59.000Z

215

Electron Microscopical Investigations of Organic Solar Cells.  

E-Print Network [OSTI]

??Diese Arbeit behandelt die Analyse der Nanomorphologie von organischen Solarzellen, welchen einen großen Einfluss auf die Effizienz der Zelle hat. Ein breites Spektrum elektronenmikroskopischer Techniken… (more)

Pfaff, Marina

2013-01-01T23:59:59.000Z

216

Ion photon emission microscope  

DOE Patents [OSTI]

An ion beam analysis system that creates microscopic multidimensional image maps of the effects of high energy ions from an unfocussed source upon a sample by correlating the exact entry point of an ion into a sample by projection imaging of the ion-induced photons emitted at that point with a signal from a detector that measures the interaction of that ion within the sample. The emitted photons are collected in the lens system of a conventional optical microscope, and projected on the image plane of a high resolution single photon position sensitive detector. Position signals from this photon detector are then correlated in time with electrical effects, including the malfunction of digital circuits, detected within the sample that were caused by the individual ion that created these photons initially.

Doyle, Barney L. (Albuquerque, NM)

2003-04-22T23:59:59.000Z

217

the microscopic description  

E-Print Network [OSTI]

at the Bragg peak Penetration Energy Stopping power dE/dx Electronic stopping Nuclear stopping Insulator gap How is energy deposited (ions...) Water Relativedose(%) Depth (mm) Energy Dose and dosimetry Energy electronic stopping Low Energy nuclear stopping Direct DNA ionization (photons, electron impact

Giraud, Olivier

218

Electron  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

to measure the electron density gradient and its fluctuations. Two separate laser beams with slight spatial offset and frequency difference are coupled into a single mixer...

219

Fluorescence, Single-Molecule Microscope | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Single-Molecule Microscope Fluorescence, Single-Molecule Microscope The single-molecule optical microscope is designed to study complex reaction dynamics such as enzymatic...

220

A Microscopic Double-Slit Experiment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

A Microscopic Double-Slit A Microscopic Double-Slit Experiment A Microscopic Double-Slit Experiment Print Wednesday, 29 February 2012 00:00 Two centuries ago, Thomas Young performed the classic demonstration of the wave nature of light. He placed a screen with two tiny slits in front of a single light source, effectively converting it into a two-centered source. On a second screen far away, he saw a pattern of light and dark diffraction fringes, a well-known hallmark of wave interference. Along with later studies using particles instead of light, the experiment played a crucial role in establishing the validity of wave-particle duality, a puzzling concept that has ultimately become central to the interpretation of complementarity in quantum mechnanics. In a new twist on this classic experiment, the double slit (with light waves) has been replaced by a diatomic molecule (with electron waves). At ALS Beamline 10.0.1, researchers have shown that diatomic molecules can serve as two-center emitters of electron waves and that traces of electron-wave interference can be directly observed in precise measurements of vibrationally resolved photoionization spectra.

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Atomic Force Microscope  

SciTech Connect (OSTI)

The Atomic Force Microscope (AFM) is a recently developed instrument that has achieved atomic resolution imaging of both conducting and non- conducting surfaces. Because the AFM is in the early stages of development, and because of the difficulty of building the instrument, it is currently in use in fewer than ten laboratories worldwide. It promises to be a valuable tool for obtaining information about engineering surfaces and aiding the .study of precision fabrication processes. This paper gives an overview of AFM technology and presents plans to build an instrument designed to look at engineering surfaces.

Day, R.D.; Russell, P.E.

1988-12-01T23:59:59.000Z

222

A compact scanning soft X-ray microscope  

SciTech Connect (OSTI)

Soft x-ray microscopes operating at wavelengths between 2.3 nm and 4.4 nm are capable of imaging wet biological cells with a resolution many times that of a visible light microscope. Several such soft x-ray microscopes have been constructed. However, with the exception of contact microscopes, all use synchrotrons as the source of soft x-ray radiation and Fresnel zone plates as the focusing optics. These synchrotron based microscopes are very successful but have the disadvantage of limited access. This dissertation reviews the construction and performance of a compact scanning soft x-ray microscope whose size and accessibility is comparable to that of an electron microscope. The microscope uses a high-brightness laser-produced plasma as the soft x-ray source and normal incidence multilayer-coated mirrors in a Schwarzschild configuration as the focusing optics. The microscope operates at a wavelength of 14 nm, has a spatial resolution of 0.5 {mu}m, and has a soft x-ray photon flux through the focus of 10{sup 4}-10{sup 5} s{sup {minus}1} when operated with only 170 mW of average laser power. The complete system, including the laser, fits on a single 4{prime} x 8{prime} optical table. The significant components of the compact microscope are the laser-produced plasma (LPP) source, the multilayer coatings, and the Schwarzschild objective. These components are reviewed, both with regard to their particular use in the current microscope and with regard to extending the microscope performance to higher resolution, higher speed, and operation at shorter wavelengths. Measurements of soft x-ray emission and debris emission from our present LPP source are presented and considerations given for an optimal LPP source. The LPP source was also used as a broadband soft x-ray source for measurement of normal incidence multilayer mirror reflectance in the 10-25 nm spectral region.

Trail, J.A.

1989-01-01T23:59:59.000Z

223

Electron  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Electron thermal transport within magnetic islands in the reversed-field pinch a... H. D. Stephens, 1,b D. J. Den Hartog, 1,3 C. C. Hegna, 1,2 and J. A. Reusch 1 1 Department of...

224

Negative differential transmission in graphene  

Science Journals Connector (OSTI)

By using the Kubo linear response theory with the Keldysh Green function approach, we investigate the mechanism leading to the negative differential transmission in a system with the equilibrium electron density much smaller than the photon-excited one. It is shown that the negative differential transmission can appear at low probe-photon energy (in the order of the scattering rate) or at high energy (much larger than the scattering rate). For the low probe-photon energy case, the negative differential transmission is found to come from the increase of the intraband conductivity due to the large variation of electron distribution after the pumping. As for the high probe-photon energy case, the negative differential transmission is shown to tend to appear with the hot-electron temperature being closer to the equilibrium one and the chemical potential higher than the equilibrium one but considerably smaller than half of the probe-photon energy. We also show that this negative differential transmission can come from both the inter- and the intraband components of the conductivity. Especially, for the interband component, its contribution to the negative differential transmission is shown to come from both the Hartree-Fock self-energy and the scattering. Furthermore, the influence of the Coulomb-hole self-energy is also addressed.

B. Y. Sun and M. W. Wu

2013-12-17T23:59:59.000Z

225

Transmission Investment: A Primer  

SciTech Connect (OSTI)

This primer highlights recent trends in transmission investment, summarizes the division of jurisdictional authority over transmission, and presents four alternative models for transmission ownership. (author)

McGarvey, Joe

2006-10-15T23:59:59.000Z

226

Transmission | Open Energy Information  

Open Energy Info (EERE)

Transmission Lattice.jpg High-voltage transmission lines form the backbone of electricity systems. Transmission lines are designed to carry large amounts of electricity at...

227

Field emission of electrons from a Cs-doped single carbon nanotube of known chiral indices  

E-Print Network [OSTI]

kV. The diffraction pattern Fig. 1 b was recorded on a charge-coupled device camera with the camera carbon nano- tube. Figure 1 a is a transmission electron microscope TEM image which shows a single carbon determined from the ratios of v/u= 2D2-D1 / 2D1-D2 for each shell, where D1 and D2 are the layer line

Qin, Lu-Chang

228

Comparison of four paper imaging techniques;. beta. -radiography, electrography, light transmission, and soft x-radiography  

SciTech Connect (OSTI)

This paper discusses four paper imaging techniques ({beta}-radiography, electrography, light transmission, and soft X-radiography) which were compared in terms of their process parameters and image characteristics (exposure time, spatial variation, contrast, spatial resolution, correlation with mass, and limitation in basis weight range) with the same newsprint samples and the same electron microscope film. Electrography gave a higher spatial resolution, shorter exposure time, and the wider basis weight range than {beta}-radiography. The light transmission image could be obtained in a very short time, but it gave the poorest spatial resolution and correlation with mass. Soft X-radiography gave the biggest spatial resolution but the poorest spatial variation and contrast.

Tomimasu, H. (Mitsubishi Paper Mills, Ltd., Central Research Inst., 1-4-1 Higashi-Kanamachi, Istsushiba-ku, Tokyo 125 (JP)); Kim, D.; Suk, M. (Syracuse Univ., Dept. of Electrical and Computer Engineering, Syracuse, NY (US)); Luner, P. (State Univ. of New York, College of Environmental Science and Forestry, Syracuse, NY (US))

1991-07-01T23:59:59.000Z

229

Soft x-ray laser microscope. Final report  

SciTech Connect (OSTI)

The program consisted of two phases (Phase I and Phase II). The goal of the Phase I (first year program) was to design and construct the Soft X-ray Laser Contact Microscope. Such microscope was constructed and adapted to PPL`s 18.2nm soft X-ray Laser (SXL), which in turn was modified and prepared for microscopy experiments. Investigation of the photoresist response to 18.2nm laser radiation and transmissivity of 0.1m thick silicion-nitride (Si{sub 3}N{sub 4}) windows were important initial works. The goal of the first year of Phase II was to construct X-ray contact microscope in combination with existing optical phase microscope, already used by biologists. In the second year of Phase II study of dehydrated Horeseshoe Crab and Hela cancer cells were performed with COXRALM. Also during Phase II, the Imaging X-Ray Laser Microscope (IXRALM) was designed and constructed. This paper describes the development of each of the microscopes and their application for research.

Suckewer, P.I.

1990-10-01T23:59:59.000Z

230

Optoelectronics 514 Transmission Hologram Transmission Hologram  

E-Print Network [OSTI]

Optoelectronics 514 Transmission Hologram Transmission Hologram Purpose: To learn about making Procedure: 1. HeNe Laser: #12;Optoelectronics 514 Transmission Hologram Mount the laser along the long axis. Development #12;Optoelectronics 514 Transmission Hologram Put the plate in the developer emulsion side up

Collins, Gary S.

231

A Microscopic Double-Slit Experiment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

A Microscopic Double-Slit Experiment Print A Microscopic Double-Slit Experiment Print Two centuries ago, Thomas Young performed the classic demonstration of the wave nature of light. He placed a screen with two tiny slits in front of a single light source, effectively converting it into a two-centered source. On a second screen far away, he saw a pattern of light and dark diffraction fringes, a well-known hallmark of wave interference. Along with later studies using particles instead of light, the experiment played a crucial role in establishing the validity of wave-particle duality, a puzzling concept that has ultimately become central to the interpretation of complementarity in quantum mechnanics. In a new twist on this classic experiment, the double slit (with light waves) has been replaced by a diatomic molecule (with electron waves). At ALS Beamline 10.0.1, researchers have shown that diatomic molecules can serve as two-center emitters of electron waves and that traces of electron-wave interference can be directly observed in precise measurements of vibrationally resolved photoionization spectra.

232

A Microscopic Double-Slit Experiment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

A Microscopic Double-Slit Experiment Print A Microscopic Double-Slit Experiment Print Two centuries ago, Thomas Young performed the classic demonstration of the wave nature of light. He placed a screen with two tiny slits in front of a single light source, effectively converting it into a two-centered source. On a second screen far away, he saw a pattern of light and dark diffraction fringes, a well-known hallmark of wave interference. Along with later studies using particles instead of light, the experiment played a crucial role in establishing the validity of wave-particle duality, a puzzling concept that has ultimately become central to the interpretation of complementarity in quantum mechnanics. In a new twist on this classic experiment, the double slit (with light waves) has been replaced by a diatomic molecule (with electron waves). At ALS Beamline 10.0.1, researchers have shown that diatomic molecules can serve as two-center emitters of electron waves and that traces of electron-wave interference can be directly observed in precise measurements of vibrationally resolved photoionization spectra.

233

In-line electron holography with an atomic focuser source  

Science Journals Connector (OSTI)

The resolution that may be achieved in an image formed by reconstruction from an in-line electron hologram, without aberration correction, is governed by the source size. Computer simulations show that ultrahigh resolution, of better than 0.05 nm for 100 keV electrons, may be possible if the electron source is a crossover formed at the exit face of a thin atomic-focuser crystal when electrons from a beam focused in a scanning transmission electron microscope (STEM) instrument are channeled along a line of atoms through the crystal. Simulations also show that, because of the channeling effect, the resolution of the reconstructed image is not degraded by translations or oscillations of the STEM beam by 0.1 nm or more. We suggest a scheme for removing the unwanted background and conjugate image from the reconstructed image by combining the in-line holography with an off-axis mode.

V. V. Smirnov and J. M. Cowley

2002-01-23T23:59:59.000Z

234

Transmission | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Transmission Transmission Transmission Below are resources for Tribes on transmission. Transmission 101 Presentation from the National Council on Electricity Policy's Transmissions Technologies workshop. Includes information on transmission technology, costs, and how to plan the system. Transmission on Tribal Land Basics The Tribal Energy and Environmental Information Clearinghouse provides resources for development on tribal lands. Topics covered include transmission technology basics, potential impacts, law and regulations, and tribal incentives. Transmission Pre-Feasibility Study for Tribes Presentation on the components of a pre-feasibility study including generation location, sizing, and desirability, ability and cost to deliver, capacity versus energy, time of delivery versus peak, request for

235

Epi-Fluorescence Inverted Microscope (Zeiss,  

E-Print Network [OSTI]

Epi-Fluorescence Inverted Microscope (Zeiss, Observer Z1) April 2013 #12;Start Up cont. · Turn) #12;Using the Microscope cont. · On an inverted microscope samples on a glass slide are usually viewed

Subramanian, Venkat

236

Coherence-controlled holographic microscope  

Science Journals Connector (OSTI)

Transmitted-light coherence-controlled holographic microscope (CCHM) based on an off-axis achromatic interferometer allows us to use light sources of arbitrary degree of temporal and...

Kolman, Pavel; Chmelík, Radim

2010-01-01T23:59:59.000Z

237

Spectro-Microscopic Measurements of Carbonaceous Aerosol Aging in Central California  

SciTech Connect (OSTI)

Carbonaceous aerosols are responsible for large uncertainties in climate models, degraded visibility, and adverse health effects. The Carbonaceous Aerosols and Radiative Effects Study (CARES) was designed to study carbonaceous aerosols in the natural environment of Central Valley, California, and learn more about their atmospheric formation and aging. This paper presents results from spectro-microscopic measurements of carbonaceous particles collected during CARES at the time of pollution accumulation event (June 27-29, 2010), when in situ measurements indicated an increase in the organic carbon content of aerosols as the Sacramento urban plume aged. Computer controlled scanning electron microscopy coupled with an energy dispersive X-ray detector (CCSEM/EDX) and scanning transmission X-ray microscopy coupled with near edge X-ray absorption spectroscopy (STXM/NEXAFS) were used to probe the chemical composition and morphology of individual particles. It was found that the mass of organic carbon on individual particles increased through condensation of secondary organic aerosol. STXM/NEXAFS indicated that the number fraction of homogenous organic particles lacking inorganic inclusions (greater than ~50 nm diameter) increased with plume age as did the organic mass per particle. Comparison of the CARES spectro-microscopic data set with a similar dataset obtained in Mexico City during the MILAGRO campaign showed that individual particles in Mexico City contained twice as much carbon as those sampled during CARES. The number fraction of soot particles at the Mexico City urban site (30%) was larger than at the CARES urban site (10%) and the most aged samples from CARES contained less carbon-carbon double bonds. Differences between carbonaceous particles in Mexico City and California result from different sources, photochemical conditions, gas phase reactants, and secondary organic aerosol precursors. The detailed results provided by these spectro-microscopic measurements will allow for a comprehensive evaluation of aerosol process models used in climate research.

Moffet, Ryan C.; Rodel, Tobias; Kelly, Stephen T.; Yu, Xiao-Ying; Carroll, Gregory; Fast, Jerome D.; Zaveri, Rahul A.; Laskin, Alexander; Gilles, Mary K.

2013-10-29T23:59:59.000Z

238

ADVANCES IN ELECTRONICS AND ELECTRON PHYSICS, VOL. 83 LVSEM for High Resolution Topographic and Density  

E-Print Network [OSTI]

ADVANCES IN ELECTRONICS AND ELECTRON PHYSICS, VOL. 83 LVSEM for High Resolution Topographic Surface-Imaging Scanning Electron Microscope 205 C. Electrons as Probes in Scanning Microscopes 205 D. Limitations Associated with the Use of Electrons as the Probing Radiation 206 E. Response to These Limitations

Pawley, James

239

MICROSCOPIC USES OF NANOGOLD.  

SciTech Connect (OSTI)

Gold has been used for immunocytochemistry since 1971 when Faulk and Taylor discovered adsorption of antibodies to colloidal gold. It is an ideal label for electron microscopy (EM) due to its high atomic number, which scatters electrons efficiently, and the fact that preparative methods have been developed to make uniform particles in the appropriate size range of 5 to 30 nm. Use in light microscopy (LM) generally requires silver enhancement (autometallography; AMG) of these small gold particles. Significant advances in this field since that time have included a better understanding of the conditions for best antibody adsorption, more regular gold size production, adsorption of other useful molecules, like protein A, and advances in silver enhancement. Many studies have also been accomplished showing the usefulness of these techniques to cell biology and biomedical research. A further advance in this field was the development of Nanogold{trademark}, a 1.4 nm gold cluster. A significant difference from colloidal gold is that Nanogold is actually a coordination compound containing a gold core covalently linked to surface organic groups. These in turn may be covalently attached to antibodies. This approach to immunolabeling has several advantages compared to colloidal gold such as vastly better penetration into tissues, generally greater sensitivity, and higher density of labeling. Since Nanogold is covalently coupled to antibodies, it may also be directly coupled to almost any protein, peptide, carbohydrate, or molecule of interest, including molecules which do not adsorb to colloidal gold. This increases the range of probes possible, and expands the applications of gold labeling.

HAINFELD,J.F.POWELL,R.D.FURUYA,F.R.

2003-04-17T23:59:59.000Z

240

Reading Comprehension - Dissecting and Compound Microscopes  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Dissecting and Compound Microscopes Two types of microscopes. _________ Dissecting and Compound Microscopes Two types of microscopes. _________ Dissecting Microscope Compound Microscope _________ eyepiece focus knob light light switch objective stage _________ eyepiece focus knob light light switch objective stage _________ eyepiece focus knob light light switch objective stage _________ eyepiece focus knob light light switch objective stage _________ eyepiece focus knob light light switch objective stage _________ eyepiece focus knob light light switch objective stage _________ Dissecting Microscope Compound Microscope _________ eyepieces focus knob light light switch objective stage _________ eyepieces focus knob light light switch objective stage _________ eyepieces focus knob light light switch objective stage _________ eyepieces focus knob light

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Science, Optics and You: Microscopes and Crystals  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

glass), and the field microscope. (The hand lens and field microscope are in your Science, Optics and You package.) Activity 14 provides instructions for making different...

242

MIAMI: Microscope and ion accelerator for materials investigations  

SciTech Connect (OSTI)

A transmission electron microscope (TEM) with in situ ion irradiation has been built at the University of Salford, U.K. The system consists of a Colutron G-2 ion source connected to a JEOL JEM-2000FX TEM via an in-house designed and constructed ion beam transport system. The ion source can deliver ion energies from 0.5 to 10 keV for singly charged ions and can be floated up to 100 kV to allow acceleration to higher energies. Ion species from H to Xe can be produced for the full range of energies allowing the investigation of implantation with light ions such as helium as well as the effects of displacing irradiation with heavy inert or self-ions. The ability to implant light ions at energies low enough such that they come to rest within the thickness of a TEM sample and to also irradiate with heavier species at energies sufficient to cause large numbers of atomic displacements makes this facility ideally suited to the study of materials for use in nuclear environments. TEM allows the internal microstructure of a sample to be imaged at the nanoscale. By irradiating in situ it is possible to observe the dynamic evolution of radiation damage which can occur during irradiation as a result of competing processes within the system being studied. Furthermore, experimental variables such as temperature can be controlled and maintained throughout both irradiation and observation. This combination of capabilities enables an understanding of the underlying atomistic processes to be gained and thus gives invaluable insights into the fundamental physics governing the response of materials to irradiation. Details of the design and specifications of the MIAMI facility are given along with examples of initial experimental results in silicon and silicon carbide.

Hinks, J. A.; Berg, J. A. van den; Donnelly, S. E. [Centre for Materials and Physics, University of Salford, The Crescent, Salford, Greater Manchester M5 4WT (United Kingdom)

2011-03-15T23:59:59.000Z

243

Strain relief and AlSb buffer layer morphology in GaSb heteroepitaxial films grown on Si as revealed by high-angle annular dark-field scanning transmission electron microscopy  

SciTech Connect (OSTI)

The interfacial misfit (IMF) dislocation array of an epitaxial GaSb film on a Si substrate has been imaged with high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM). The mismatch strain accommodation through dislocation formation has been investigated using geometric phase analysis (GPA) on HAADF-STEM images with atomic resolution to probe the defects' local strain distribution. These measurements indicate that the lattice parameter of the epitaxial film recovers its bulk value within three unit cells from the interface due to the relaxation through IMF dislocations. The atomic number contrast of the HAADF-STEM images and energy dispersive x-ray spectrometry illustrate the formation of islands of AlSb buffer layer along the interface. The role of the AlSb buffer layer in facilitating the GaSb film growth on Si is further elucidated by investigating the strain field of the islands with the GPA.

Vajargah, S. Hosseini; Couillard, M.; Cui, K. [Department of Material Science and Engineering, McMaster University, 1280 Main St. W., Hamilton, Ontario L8S 4M1 (Canada); Tavakoli, S. Ghanad; Robinson, B.; Kleiman, R. N.; Preston, J. S. [Department of Engineering Physics, McMaster University, Hamilton, Ontario L8S 4M1 (Canada); Botton, G. A. [Department of Material Science and Engineering, McMaster University, 1280 Main St. W., Hamilton, Ontario L8S 4M1 (Canada); Canadian Centre for Electron Microscopy, McMaster University, Hamilton, Ontario L8S 4M1 (Canada)

2011-02-21T23:59:59.000Z

244

Survey of Transmission Cost Allocation Methodologies for Regional Transmission Organizations  

SciTech Connect (OSTI)

The report presents transmission cost allocation methodologies for reliability transmission projects, generation interconnection, and economic transmission projects for all Regional Transmission Organizations.

Fink, S.; Porter, K.; Mudd, C.; Rogers, J.

2011-02-01T23:59:59.000Z

245

Microscopy. II. Electron Microscopy: A Review  

Science Journals Connector (OSTI)

...the best image under the lower resolving power of optical microscopes. For example...Experimental Infection with the Virus of Foot and Mouth Disease. J. Exper. Med...Further Improvements in the Resolving Power of the Electron Microscope. J. Appi...

Cecily Cannan Selby

1953-11-01T23:59:59.000Z

246

Transmission Business Unit Manager  

Broader source: Energy.gov [DOE]

(See Frequently Asked Questions for more information). Where would I be working? Western Area Power Administration Rocky Mountain Region Transmission Services, (J7300) Transmission Busiess Unit 615...

247

Installation of the MAXIMUM microscope at the ALS  

SciTech Connect (OSTI)

The MAXIMUM scanning x-ray microscope, developed at the Synchrotron Radiation Center (SRC) at the University of Wisconsin, Madison was implemented on the Advanced Light Source in August of 1995. The microscope`s initial operation at SRC successfully demonstrated the use of multilayer coated Schwarzschild objective for focusing 130 eV x-rays to a spot size of better than 0.1 micron with an electron energy resolution of 250meV. The performance of the microscope was severely limited, because of the relatively low brightness of SRC, which limits the available flux at the focus of the microscope. The high brightness of the ALS is expected to increase the usable flux at the sample by a factor of 1,000. The authors will report on the installation of the microscope on bending magnet beamline 6.3.2 at the ALS and the initial measurement of optical performance on the new source, and preliminary experiments with surface chemistry of HF etched Si will be described.

Ng, W.; Perera, R.C.C.; Underwood, J.H. [Lawrence Berkeley Lab., CA (United States); Singh, S.; Solak, H.; Cerrina, F. [Univ. of Wisconsin, Stoughton, WI (United States). Center for X-ray Lithography

1995-10-01T23:59:59.000Z

248

The History of the Microscope  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

the Microscope the Microscope Nature Bulletin No. 506 November 9, 1957 Forest Preserve District of Cook County Daniel Ryan, President Roberts Mann, Conservation Editor David H. Thompson, Senior Naturalist THE HISTORY OF THE MICROSCOPE During that historic period known as the Renaissance, after the "dark" Middle Ages, there occurred the inventions of printing, gunpowder and the mariner's compass, followed by the discovery of America. Equally remarkable was the invention of the microscope: an instrument that enables the human eye, by means of a lens or combinations of lenses, to observe enlarged images of tiny objects. It made visible the fascinating details of worlds within worlds. Long before, in the hazy unrecorded past, someone picked up a piece of transparent crystal thicker in the middle than at the edges, looked through it, and discovered that it made things look larger. Someone also found that such a crystal would focus the sun's rays and set fire to a piece of parchment or cloth. Magnifiers and "burning glasses" are mentioned in the writings of Seneca and Pliny the Elder, Roman philosophers during the first century A. D., but apparently they were not used much until the invention of spectacles, toward the end of the 13th century. They were named lenses because they are shaped like the seeds of a lentil.

249

Comparison between direct methods for determination of microbial cell volume: electron microscopy and electronic particle sizing.  

Science Journals Connector (OSTI)

...than those processed for electronic particle sizing, reflecting...Electron Microscopy and Electronic Particle Sizing E. MONTESINOS...ofMicrobiology and Institute for Fundamental Biology, Autonomous University...transmission electron microscopy and electronic particle sizing. Statistically...

E Montesinos; I Esteve; R Guerrero

1983-05-01T23:59:59.000Z

250

San Luis Transmission Project  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Luis Transmission Project EIS/EIR Luis Transmission Project EIS/EIR San Luis Transmission Project EIS/EIR Western proposes to construct, own, operate, and maintain a new 230-kilovolt transmission line about 62 miles in length between Western's Tracy Substation and Western's San Luis Substation and a new 70-kV transmission line about 5 miles in length between the San Luis and O'Neill Substations. Western also will consider other transmission construction options including: A new 500-kV transmission line about 62 miles in length operated at 230-kV between Western's Tracy and San Luis Substations; A new 500-kV transmission line operated at 500-kV about 62 miles in length between the Tracy Substation and Pacific Gas and Electric's Los Banos Substation; and A new 230-kV transmission line about 18 miles in length between San Luis Substation and Dos Amigos Substation.

251

Probing the electronic structure and optical response of a graphene quantum disk supported on monolayer graphene  

SciTech Connect (OSTI)

In this paper, we show that a graphene quantum disk (GQD) can be generated on monolayer graphene via structural modification using the electron beam. The electronic structure and local optical responses of the GQD, supported on monolayer graphene, were probed with electron energy-loss spectrum imaging on an aberration-corrected scanning transmission electron microscope. We observe that for small GQD, {approx}1.3 nm in diameter, the electronic structure and optical response are governed by the dominating edge states, and are distinctly different from either monolayer graphene or double-layer graphene. Highly localized plasmon modes are generated at the GQD due to the confinement from the edge of the GQD in all directions. The highly localized optical response from GQDs could find use in designing nanoscale optoelectronic and plasmonic devices based on monolayer graphene.

Zhou, Wu [Vanderbilt University; Pennycook, Stephen J [ORNL; Idrobo Tapia, Juan C [ORNL

2012-01-01T23:59:59.000Z

252

Integrated Dynamic Electron Solutions, Inc. | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Integrated Integrated Dynamic Electron Solutions, Inc. America's Next Top Energy Innovator Challenge 333 likes Integrated Dynamic Electron Solutions, Inc. Lawrence Livermore National Laboratory Dynamic Transmission Electron Microscopes DTEM reveal unprecedented details of the mechanisms underlying a host of nanoscale systems that are at the core of our current and future energy economy. A vast and growing number of materials utilized in the energy sector rely on nanostructured materials and their unique dynamic behaviors. DTEM offers researchers the ability to directly interrogate these materials at time and length scales that to-date have either been impossible to access or required the use of multi-billion dollar synchrotrons. DTEM will fundamentally change the approach to basic and applied research in the

253

Integrated Dynamic Electron Solutions, Inc. | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Integrated Integrated Dynamic Electron Solutions, Inc. America's Next Top Energy Innovator Challenge 333 likes Integrated Dynamic Electron Solutions, Inc. Lawrence Livermore National Laboratory Dynamic Transmission Electron Microscopes DTEM reveal unprecedented details of the mechanisms underlying a host of nanoscale systems that are at the core of our current and future energy economy. A vast and growing number of materials utilized in the energy sector rely on nanostructured materials and their unique dynamic behaviors. DTEM offers researchers the ability to directly interrogate these materials at time and length scales that to-date have either been impossible to access or required the use of multi-billion dollar synchrotrons. DTEM will fundamentally change the approach to basic and applied research in the

254

Integrated Dynamic Electron Solutions, Inc. | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Integrated Integrated Dynamic Electron Solutions, Inc. America's Next Top Energy Innovator Challenge 333 likes Integrated Dynamic Electron Solutions, Inc. Lawrence Livermore National Laboratory Dynamic Transmission Electron Microscopes DTEM reveal unprecedented details of the mechanisms underlying a host of nanoscale systems that are at the core of our current and future energy economy. A vast and growing number of materials utilized in the energy sector rely on nanostructured materials and their unique dynamic behaviors. DTEM offers researchers the ability to directly interrogate these materials at time and length scales that to-date have either been impossible to access or required the use of multi-billion dollar synchrotrons. DTEM will fundamentally change the approach to basic and applied research in the

255

Atomic Force Compound Microscope | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and spectroscopic characterization simultaneously for imaging biological... Intermittent Single-Molecule Interfacial Electron Transfer Dynamics. We report on single molecule...

256

National Transmission Grid Study  

Broader source: Energy.gov (indexed) [DOE]

Grid Study Grid Study U.S. Department of Energy The Honorable Spencer Abraham Secretary of Energy May 2002 ii National Transmission Grid Study National Transmission Grid Study i ii National Transmission Grid Study National Transmission Grid Study iii How This Study Was Conducted The National Energy Policy Plan directed the U.S. Department of Energy (DOE) to conduct a study to examine the benefits of establishing a national electricity transmission grid and to identify transmission bottlenecks and measures to address them. DOE began by conducting an independent analysis of U.S. electricity markets and identifying transmission system bottlenecks using DOE's Policy Office Electricity Modeling System (POEMS). DOE's analysis, presented in Section 2, confirms the central role of the nation's transmission

257

Transmission | Open Energy Information  

Open Energy Info (EERE)

Gateway Gateway Edit History Facebook icon Twitter icon » Transmission (Redirected from Transmission) Jump to: navigation, search Transmission header.png Transmission Dashboard Permitting Atlas Compare States Arizona California Colorado Idaho Montana Nevada New Mexico Oregon Utah Washington Wyoming Resource Library NEPA Database Transmission Lattice.jpg High-voltage transmission lines form the backbone of electricity systems. Transmission lines are designed to carry large amounts of electricity at high voltages, typically 115 to 500 kilovolts (kV), across long distances. Networks of transmission lines transfer electricity from power plants or other interconnections to substations. At substations, the high-voltage electricity is "stepped down" to a lower voltage, which can be carried

258

STRATEGIC TRANSMISSION INVESTMENT PLAN  

E-Print Network [OSTI]

CALIFORNIA ENERGY COMMISSION STRATEGIC TRANSMISSION INVESTMENT PLAN Prepared in Support of the 2007. Blevins #12; i ACKNOWLEDGEMENTS The 2007 Strategic Transmission Investment Plan was prepared Investment Plan. California Energy Commission, Engineering Office. CEC7002007018CTF. #12; ii #12; iii

259

STRATEGIC TRANSMISSION INVESTMENT PLAN  

E-Print Network [OSTI]

CALIFORNIA ENERGY COMMISSION STRATEGIC TRANSMISSION INVESTMENT PLAN Prepared in Support of the 2007 Investment Plan was prepared with contribution from the following Energy Commission staff and consultants Kondoleon, Chuck Najarian. 2007 Strategic Transmission Investment Plan. California Energy Commission

260

Calculations of atomic sputtering and displacement cross-sections in solid elements by electrons with energies from threshold to 1. 5 MV  

SciTech Connect (OSTI)

The kinetics of knock-on collisions of relativistic electrons with nuclei and details of the numerical evaluation of differential, recoil, and total Mott cross-sections are reviewed and discussed. The effects of electron beam induced displacement and sputtering, in the transmission electron microscope (TEM) environment, on microanalysis are analyzed with particular emphasis placed on the removal of material by knock-on sputtering. The mass loss predicted due to transmission knock-on sputtering is significant for many elements under conditions frequently encountered in microanalysis. Total Mott cross-sections are tabulated for all naturally occurring solid elements up to Z = 92 at displacement energies of one, two, four, and five times the sublimation energy and for accelerating voltages accessible in the transmission electron microscope. Fortran source code listings for the calculation of the differential Mott cross-section as a function of electron scattering angle (dMottCS), as a function of nuclear recoil angle (RECOIL), and the total Mott cross-section (TOTCS) are included. 48 refs., 21 figs., 12 tabs.

Bradley, C.R.

1988-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

From electron energy-loss spectroscopy to multi-dimensional and multi-signal electron microscopy  

Science Journals Connector (OSTI)

......4 Colliex C . Electron Energy Loss Spectroscopy in the...eds. (1984) Vol. 9. New York: Academic Press. 65-177. 5 Egerton R . Electron Energy Loss Spectroscopy in the Electron Microscope (1986) New York: Plenum Press. 6 Isaacson......

Christian Colliex

2011-08-01T23:59:59.000Z

262

Transmission Utilization Group (TUG)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Improvement (CBPI) Customer Forum Energy Imbalance Market Generator Interconnection Reform Implementation Intertie Initiatives Intertie Open Season Transmission Utilization...

263

Transmission Commercial Project Integration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Improvement (CBPI) Customer Forum Energy Imbalance Market Generator Interconnection Reform Implementation Network Integration Transmission Service (NT Service) Network Open...

264

Underground Power Transmission  

Science Journals Connector (OSTI)

...The type of transmission line for a particular...will force rt transmission lines to be ground near...history of power transmission shows that d-c...characteristics of a d-c line, it is easy to...Best data fit III II I...

P. H. Rose

1970-10-16T23:59:59.000Z

265

Vice President, Transmission Marketing & Sales  

Broader source: Energy.gov [DOE]

Within Transmission Services at Bonneville Power Administration (BPA), Transmission Marketing and Sales (TS) provides open access to the Federal Transmission System (FTS) consistent with...

266

Spectro-Microscopic Study of Laser-Modified Carbon Nanotubes  

E-Print Network [OSTI]

production through the arc-discharge evaporation method.(1) Using transmission electron microscopy (TEM is an extremely valuable for energy storage.(8) Besides, it is important for nano-electric devices due to its trimming the CNTs array by focused laser, the turn-on electric field decreases and its emission current

Lin, Minn-Tsong

267

Transmission | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Gateway Edit History Facebook icon Twitter icon » Transmission Jump to: navigation, search Transmission header.png Transmission Dashboard Permitting Atlas Compare States Arizona California Colorado Idaho Montana Nevada New Mexico Oregon Utah Washington Wyoming Resource Library NEPA Database Transmission Lattice.jpg High-voltage transmission lines form the backbone of electricity systems. Transmission lines are designed to carry large amounts of electricity at high voltages, typically 115 to 500 kilovolts (kV), across long distances. Networks of transmission lines transfer electricity from power plants or other interconnections to substations. At substations, the high-voltage

268

Identification of Fragile Microscopic Structures during Mineral Transformations in Wet Supercritical CO2  

SciTech Connect (OSTI)

In this study we examine the nature of highly fragile reaction products that form in low water content super critical carbon dioxide (scCO2) using a combination of scanning electron microscopy/focus ion beam (SEM/FIB), confocal Raman spectroscopy, helium ion microscopy (HeIM), and transmission electron microscopy (TEM). HeIM images show these precipitates to be fragile rosettes that can readily decompose even under slight heating from an electron beam. Using the TEM revealed details on the interfacial structure between the newly formed surface precipitates and the underlying initial solid phases. The detailed microscopic analysis revealed that the growth of the precipitates either followed a tip growth mechanism with precipitates forming directly on the forsterite surface if the initial solid was non-porous (natural forsterite) or growth from the surface of the precipitates where fluid was conducted through the porous (nanoforsterite) agglomerates to the growth center. The mechanism of formation of the hydrated/hydroxylated magnesium carbonate compound (HHMC) phases offers insight into the possible mechanisms of carbonate mineral formation from scCO2 solutions which has recently received a great deal of attention as the result of the potential for CO2 to act as an atmospheric greenhouse gas and impact overall global warming. The techniques used here to examine these fragile structures an also be used to examine a wide range of fragile material surfaces. SEM and FIB technologies have now been brought together in a single instrument, which represents a powerful combination for the studies in biological, geological and materials science.

Arey, Bruce W.; Kovarik, Libor; Qafoku, Odeta; Wang, Zheming; Hess, Nancy J.; Felmy, Andrew R.

2013-04-01T23:59:59.000Z

269

High-resolution scanning transmission electron microscopy  

Science Journals Connector (OSTI)

...where, is the brightness of the source and bs/80 is the ratio of the real image of the...im-age (0.61A/a). The quantity bs/80 can be most easily defined in the source...tube can be ac-quired at a reasonable cost and is com-patible with full-color displays...

AV Crewe

1983-07-22T23:59:59.000Z

270

In situ environmental transmission electron microscopy study...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

aqueous electrolytes. 16 Based on previous studies of the oxida- tion behavior of bulk TiC 17-19 in various temperature ranges, and under various oxygen partial pressures, it is...

271

Sensing mode atomic force microscope  

DOE Patents [OSTI]

An atomic force microscope utilizes a pulse release system and improved method of operation to minimize contact forces between a probe tip affixed to a flexible cantilever and a specimen being measured. The pulse release system includes a magnetic particle affixed proximate the probe tip and an electromagnetic coil. When energized, the electromagnetic coil generates a magnetic field which applies a driving force on the magnetic particle sufficient to overcome adhesive forces exhibited between the probe tip and specimen. The atomic force microscope includes two independently displaceable piezo elements operable along a Z-axis. A controller drives the first Z-axis piezo element to provide a controlled approach between the probe tip and specimen up to a point of contact between the probe tip and specimen. The controller then drives the first Z-axis piezo element to withdraw the cantilever from the specimen. The controller also activates the pulse release system which drives the probe tip away from the specimen during withdrawal. Following withdrawal, the controller adjusts the height of the second Z-axis piezo element to maintain a substantially constant approach distance between successive samples.

Hough, Paul V. C. (Port Jefferson, NY); Wang, Chengpu (Upton, NY)

2003-01-01T23:59:59.000Z

272

Los Alamos: MST: MST-6: EML: Electron Microscopy Laboratory  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Strata DB235 FIB/SEM (Focused Ion Beam/High Reolution Scanning Electron Microscope) Strata DB235 FIB/SEM (Focused Ion Beam/High Reolution Scanning Electron Microscope) FEI Strata DB235 FIB/SEM (Focused Ion Beam/High Reolution Scanning Electron Microscope) This is a versatile field emission scanning electron microscope integrated with a focused ion beam column that is used for sophisticated SEM and TEM sample preparation, micromachining, and ultrahigh resolution SEM imaging. The microscope is also equipped for x-ray microanalysis and crystallographic orientation imaging. Microscope consists of a Hexalens SFEG electron beam column, and a Magnum ion beam column with a gallium liquid metal ion source. Imaging with both secondary electrons and ions. Digital image acquisition. Small, stable, high brightness Schottky based field emission electron source provides 1.5 nm resolution at 30 kV. Three electron beam lens modes - normal imaging, high resolution imaging, and EDS imaging.

273

A New Cubic B-C-N Compound Revealed by High-Resolution Analytical Electron Microscopy  

Science Journals Connector (OSTI)

......nitride by electron energy-loss spectroscopy...Egerton RF: Electron energy loss spectroscopy...electron microscope. New York and London: Plenum...electron microscopy. New York: Plenum Press...system by electron energy loss spectroscopy......

Yoshio Bando; Satoshi Nakano; Keiji Kurashima

1996-04-01T23:59:59.000Z

274

Series Transmission Line Transformer  

DOE Patents [OSTI]

A series transmission line transformer is set forth which includes two or more of impedance matched sets of at least two transmissions lines such as shielded cables, connected in parallel at one end ans series at the other in a cascading fashion. The cables are wound about a magnetic core. The series transmission line transformer (STLT) which can provide for higher impedance ratios and bandwidths, which is scalable, and which is of simpler design and construction.

Buckles, Robert A. (Livermore, CA); Booth, Rex (Livermore, CA); Yen, Boris T. (El Cerrito, CA)

2004-06-29T23:59:59.000Z

275

Stream Control Transmission Protocol  

Science Journals Connector (OSTI)

This document describes the Stream Control Transmission Protocol (SCTP). SCTP is designed to transport PSTN signaling messages over IP networks, but is capable of broader applications.

R. Stewart; Q. Xie; K. Morneault; C. Sharp; H. Schwarzbauer; T. Taylor; I. Rytina; M. Kalla; L. Zhang; V. Paxson

2000-10-01T23:59:59.000Z

276

STRATEGIC TRANSMISSION INVESTMENT PLAN  

E-Print Network [OSTI]

CALIFORNIA ENERGY COMMISSION STRATEGIC TRANSMISSION INVESTMENT PLAN Prepared in Support of the 2005............................................................................................ 5 Project Investment Recommendations ............................................................... 6 Actions to Implement Investments

277

STRATEGIC TRANSMISSION INVESTMENT PLAN  

E-Print Network [OSTI]

CALIFORNIA ENERGY COMMISSION STRATEGIC TRANSMISSION INVESTMENT PLAN Prepared in Support of the 2005............................................................................................ 5 Project Investment Recommendations ............................................................... 5 Actions to Implement Investments

278

Quantification of nanoscale density fluctuations using electron microscopy: Light-localization properties of biological cells  

SciTech Connect (OSTI)

We report a study of the nanoscale mass-density fluctuations of heterogeneous optical dielectric media, including nanomaterials and biological cells, by quantifying their nanoscale light-localization properties. Transmission electron microscope images of the media are used to construct corresponding effective disordered optical lattices. Light-localization properties are studied by the statistical analysis of the inverse participation ratio (IPR) of the localized eigenfunctions of these optical lattices at the nanoscale. We validated IPR analysis using nanomaterials as models of disordered systems fabricated from dielectric nanoparticles. As an example, we then applied such analysis to distinguish between cells with different degrees of aggressive malignancy.

Pradhan, Prabhakar; Damania, Dhwanil; Turzhitsky, Vladimir; Subramanian, Hariharan; Backman, Vadim [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 (United States); Joshi, Hrushikesh M.; Dravid, Vinayak P. [Department of Material Science and Engineering, Northwestern University, Evanston, Illinois 60208 (United States); Roy, Hemant K. [Department of Internal Medicine, NorthShore University HealthSystem, Evanston, Illinois 60201 (United States); Taflove, Allen [Department of Electrical Engineering and Computer Science, Northwestern University, Evanston, Illinois 60208 (United States)

2010-12-13T23:59:59.000Z

279

Scanning evanescent electro-magnetic microscope  

DOE Patents [OSTI]

A novel scanning microscope is described that uses near-field evanescent electromagnetic waves to probe sample properties. The novel microscope is capable of high resolution imaging and quantitative measurements of the electrical properties of the sample. The inventive scanning evanescent wave electromagnetic microscope (SEMM) can map dielectric constant, tangent loss, conductivity, complex electrical impedance, and other electrical parameters of materials. The quantitative map corresponds to the imaged detail. The novel microscope can be used to measure electrical properties of both dielectric and electrically conducting materials.

Xiang, Xiao-Dong (Alameda, CA); Gao, Chen (Alameda, CA)

2001-01-01T23:59:59.000Z

280

Magnetically insulated transmission line oscillator  

DOE Patents [OSTI]

A magnetically insulated transmission line oscillator employs self-generated magnetic fields to generate microwave energy. An anode of the oscillator includes slow-wave structures which are formed of a plurality of thin conductive vanes defining cavities therebetween, and a gap is formed between the anode and a cathode of the oscillator. In response to a pulsed voltage applied to the anode and cathode, self-generated magnetic fields arfe produced in a cross-field orientation with respect to the orientation of the electric field between the anode and the cathode. The cross-field magnetic fields insulate the flow of electrons in the gap and confine the flow of electrons within the gap.

Bacon, Larry D. (Albuquerque, NM); Ballard, William P. (Albuquerque, NM); Clark, M. Collins (Albuquerque, NM); Marder, Barry M. (Albuquerque, NM)

1988-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Transmission Line Security Monitor  

SciTech Connect (OSTI)

The Transmission Line Security Monitor is a multi-sensor monitor that mounts directly on high-voltage transmission lines to detect, characterize and communicate terrorist activity, human tampering and threatening conditions around support towers. For more information about INL's critical infrastructure protection research, visit http://www.facebook.com/idahonationallaboratory.

None

2011-01-01T23:59:59.000Z

282

Transmission Line Security Monitor  

ScienceCinema (OSTI)

The Transmission Line Security Monitor is a multi-sensor monitor that mounts directly on high-voltage transmission lines to detect, characterize and communicate terrorist activity, human tampering and threatening conditions around support towers. For more information about INL's critical infrastructure protection research, visit http://www.facebook.com/idahonationallaboratory.

None

2013-05-28T23:59:59.000Z

283

Laboratory-Based Cryogenic Soft X-ray Tomography with Correlative Cryo-Light and Electron Microscopy  

SciTech Connect (OSTI)

Here we present a novel laboratory-based cryogenic soft X-ray microscope for whole cell tomography of frozen hydrated samples. We demonstrate the capabilities of this compact cryogenic microscope by visualizing internal sub-cellular structures of Saccharomyces cerevisiae cells. The microscope is shown to achieve better than 50 nm spatial resolution with a Siemens star test sample. For whole biological cells, the microscope can image specimens up to 5 micrometers thick. Structures as small as 90 nm can be detected in tomographic reconstructions at roughly 70 nm spatial resolution following a low cumulative radiation dose of only 7.2 MGy. Furthermore, the design of the specimen chamber utilizes a standard sample support that permits multimodal correlative imaging of the exact same unstained yeast cell via cryo-fluorescence light microscopy, cryo-soft x-ray microscopy and cryo-transmission electron microscopy. This completely laboratory-based cryogenic soft x-ray microscope will therefore enable greater access to three-dimensional ultrastructure determination of biological whole cells without chemical fixation or physical sectioning.

Carlson, David B.; Gelb, Jeff; Palshin, Vadim; Evans, James E.

2013-02-01T23:59:59.000Z

284

Robotic CCD microscope for enhanced crystal recognition  

DOE Patents [OSTI]

A robotic CCD microscope and procedures to automate crystal recognition. The robotic CCD microscope and procedures enables more accurate crystal recognition, leading to fewer false negative and fewer false positives, and enable detection of smaller crystals compared to other methods available today.

Segelke, Brent W. (San Ramon, CA); Toppani, Dominique (Livermore, CA)

2007-11-06T23:59:59.000Z

285

Microscopic nonequilibrium theory of quantum well solar cells  

Science Journals Connector (OSTI)

We present a microscopic theory of bipolar quantum well structures in the photovoltaic regime, based on the nonequilibrium Green’s function formalism for a multiband tight-binding Hamiltonian. The quantum kinetic equations for the single particle Green’s functions of electrons and holes are self-consistently coupled to Poisson’s equation, including intercarrier scattering on the Hartree level. Relaxation and broadening mechanisms are considered by the inclusion of acoustic and optical electron-phonon interaction in a self-consistent Born approximation of the scattering self-energies. Photogeneration of carriers is described on the same level in terms of a self-energy derived from the standard dipole approximation of the electron-photon interaction. Results from a simple two-band model are shown for the local density of states, spectral response, current spectrum, and current-voltage characteristics for generic single quantum well systems.

U. Aeberhard and R. H. Morf

2008-03-28T23:59:59.000Z

286

Disorder-Induced Microscopic Magnetic Memory  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Disorder-Induced Microscopic Disorder-Induced Microscopic Magnetic Memory Disorder-Induced Microscopic Magnetic Memory Print Wednesday, 26 October 2005 00:00 The magnetic-recording industry deliberately introduces carefully controlled disorder into its materials to obtain the desired magnetic properties. But as the density of magnetic disks climbs, the size of the magnetic domains responsible for storage must decrease, posing new challenges. Beautiful theories based on random microscopic disorder have been developed over the past ten years. To directly compare these theories with precise experiments, an American-European team, led by researchers from the University of Washington, Seattle, first developed and then applied coherent x-ray speckle metrology to microscopic magnetic domains in a series of thin multilayer perpendicular magnetic materials of varying disorder. Their results, at odds with all previous theories, have set a new reference point for future theories.

287

NCEM National Center for Electron Microscopy: Microscopes and Facilities:  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3010 In-Situ 3010 In-Situ AEME The 300 kV JEOL 3010 offers greater specimen penetration than 200kV instruments, with significantly improved spatial resolution and probe forming capabilities. The side-entry stage allows ±45° tilt and can be operated with piezo-drift compensation. A flexible condenser system permits CBED, LACBED, and imaging with hollow cone and Koehler illumination. In addition to a standard film camera, a Gatan Orius CCD, and a Gatan 622 intensified TV camera and VCR are available for recording experiments at video rates. Specific capabilities include: high-resolution imaging at 2.1Å and ±40° tilt during simultaneous heating; very-high-resolution imaging at 1.7 Å and ±10° tilt during simultaneous heating; and high magnification Lorentz and Foucault imaging of magnetic samples. Various

288

COLONIAL GROWTH OF MYCOPLASMA GALLISEPTICUM OBSERVED WITH THE ELECTRON MICROSCOPE  

Science Journals Connector (OSTI)

...Hillier, and Mudd (1948), Reagan, Brueckner, and Delaplane (1951), Reagan, Day, and Brueckner (1953), and White, Wallace, and Alberts...697- 717. REAGAN, R. L., A. L. BRUECKNER, AND J. P. DELAPLANE. 1951. Morphological...

Moshe Shifrine; Jack Pangborn; Henry E. Adler

1962-01-01T23:59:59.000Z

289

Four generations of high-voltage electron microscopes  

Science Journals Connector (OSTI)

......TM' py and Analysis, ed. Nixon , , , , , ,, , , , W C, p. 188, (Institute of Physics Conf. Series Nr. 10, London ceed only if the ballistic exchange rate exceeds the thermal a n d Bristol). rate sufficiently. This implies that the transformation......

Alfred Seeger

1999-01-01T23:59:59.000Z

290

Low Temperature Stage in Electron Microscope for Study on Superconductors  

Science Journals Connector (OSTI)

......superconductors. The elementary magnetic property of superconductors...of the superconducting resistance-transition must be connected...stage to be movable. 2. Electric lead wires Electric lead...experiment by measuring the resistance of the specimen by the......

Tomoyuki MIYAZAKI; Ryozo AOKI; Bunjyu SHINOZAKI; Shigeru YAMASHITA

1980-01-01T23:59:59.000Z

291

Electron microscopic and voltammetric analysis of carbon fibre electrode pretreatments  

Science Journals Connector (OSTI)

The comparison between the differential pulse voltammetric capability of untreated or treated 12 µm or 30 µm diameter carbon fibre electrodes (CFE) to detect electroactive compoundsin vitro...has been analysed. T...

T. J. Self; F. Crespi

1992-11-01T23:59:59.000Z

292

Subject: SPPR Proposed ED5 to Palo Verde Transmission Project  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Date: 832010 4:02 PM Subject: SPPR Proposed ED5 to Palo Verde Transmission Project VIA ELECTRONIC MAIL TO: DSWFPP@wapa.gov August 3, 2010 Mr. Darrick...

293

Subject: SPPR Proposed ED5 to Palo Verde Transmission Project  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Date: 832010 4:04 PM Subject: SPPR Proposed ED5 to Palo Verde Transmission Project VIA ELECTRONIC MAIL TO: DSWFPP@wapa.gov August 3, 2010 Mr. Darrick...

294

EIS-0411: Transmission Agency of Northern California Transmission Project  

Broader source: Energy.gov [DOE]

This EIS is for the Western Area Power Administration construction, operation, and maintenance of the proposed transmission agency of Northern California Transmission Project, California.

295

Foil Electron Multiplier  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Foil Electron Multiplier Foil Electron Multiplier Foil Electron Multiplier An apparatus for electron multiplication by transmission that is designed with at least one foil having a front side for receiving incident particles and a back side for transmitting secondary electrons that are produced from the incident particles transiting through the foil. Available for thumbnail of Feynman Center (505) 665-9090 Email Foil Electron Multiplier An apparatus for electron multiplication by transmission that is designed with at least one foil having a front side for receiving incident particles and a back side for transmitting secondary electrons that are produced from the incident particles transiting through the foil. The foil thickness enables the incident particles to travel through the foil and continue on

296

Transmission Access Resources  

Broader source: Energy.gov [DOE]

Historically, the addition of new electric generation facilities has been accompanied by new transmission systems. For example, large nuclear and coal plants built in the 1960s and 1970s required...

297

Performance Incentives for Transmission  

E-Print Network [OSTI]

The Federal Energy Regulatory Commission's Standard Market Design Notice of Public Rule- making (SMD NOPRPerformance Incentives for Transmission FERC's Standard Market Design should accommodate of California at Berkeley. The research described in this article was supported by National Grid, USA

Oren, Shmuel S.

298

Designing electricity transmission auctions  

E-Print Network [OSTI]

The UK has ambitious plans for exploiting offshore wind for electricity production in order to meet its challenging target under the EU Renewable Energy Directive. This could involve investing up to 20bn in transmission assets to bring electricity...

Greve, Thomas; Pollitt, Michael G.

2012-10-26T23:59:59.000Z

299

Electric Transmission Lines (Iowa)  

Broader source: Energy.gov [DOE]

Electric transmission lines capable of operating at 69 kV or greater cannot be constructed along, across, or over any public highways or grounds outside of cities without a franchise from the...

300

Audio Transmission Systems  

Science Journals Connector (OSTI)

Audio transmission systems are the means by which audio signals are routed, processed, and assigned to the desired monitor and recording output channels. In the early days of electrical recording, rarely more ...

John Eargle

1986-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Transmission Grid Integration  

Broader source: Energy.gov [DOE]

The levels of solar energy penetration envisioned by the DOE SunShot Initiative must be interconnected effectively onto the transmission grid. This interconnection requires an in-depth...

302

Microscopic aspects of the Staebler-Wronski effect  

SciTech Connect (OSTI)

The microscopic origin and the creation mechanisms of metastable, light-induced defects in hydrogenated amorphous silicon are reviewed. Based on excitonic electron-hole pair recombination, a consistent quantitative description of defect creation kinetics can be obtained, including the experimentally observed differences between continuous wave and pulsed illumination as well as the effect of competing recombination pathways in compensated material. High resolution spin resonance spectra obtained by low-field spin-dependent transport are used to examine the interaction of metastable defects with hydrogen.

Stutzmann, M.

1997-07-01T23:59:59.000Z

303

Honda Transmission Technical Center  

High Performance Buildings Database

Russells Point, OH The Honda Transmission Technical Center is located on the Honda of America Manufacturing Plant facility site in Russells Point, Ohio. This facility is used for product engineering and market quality testing and analysis of automatic transmissions. The building contains a large workshop area for ten cars, a future dynamometer, two laboratories, an open office area, three conference rooms, a break room, restrooms, and related support areas.

304

EC Transmission Line Risk Identification and Analysis  

SciTech Connect (OSTI)

The purpose of this document is to assist in evaluating and planning for the cost, schedule, and technical project risks associated with the delivery and operation of the EC (Electron cyclotron) transmission line system. In general, the major risks that are anticipated to be encountered during the project delivery phase associated with the implementation of the Procurement Arrangement for the EC transmission line system are associated with: (1) Undefined or changing requirements (e.g., functional or regulatory requirements) (2) Underperformance of prototype, first unit, or production components during testing (3) Unavailability of qualified vendors for critical components Technical risks associated with the design and operation of the system are also identified.

Bigelow, Tim S [ORNL

2012-04-01T23:59:59.000Z

305

Transmission Right Of Way  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

About SNR > Right Of Way About SNR > Right Of Way Right Of Way Preferred Vegetation List - Redding & Foothills (XLS - 23K) Preferred Vegetation List - Sacramento Valley (XLS - 170K) WESTERN AREA POWER ADMINISTRATION GENERAL GUIDELINES CONCERNING THE USE OF ELECTRIC TRANSMISSION LINE RIGHTS-OF-WAY Western Area Power Administration (Western) owns a right-of-way easement along the length of the transmission line (width varies by transmission line). Western's rights within the easement include the right to construct, reconstruct, operate, maintain, and patrol the transmission line. Rights usually reserved to the landowner include the right to cultivate, occupy, and use the land for any purpose that does not conflict with Western's use of its easement. To avoid potential conflicts, it is Western's policy to review all proposed uses within the transmission line easement. We consider (1) Safety of the public, (2) Safety of our Employees, (3) Restrictions covered in the easement, (4) Western's maintenance requirements, and (5) Protection of the transmission line structures and (6) Road or street crossings.

306

Open Access Transmission Tariff  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission | OATT Transmission | OATT Skip Navigation Links Transmission Functions Infrastructure projects Interconnection OASIS OATT Western Open Access Transmission Service Tariff Revision Western Area Power Administration submitted its revised Open Access Transmission Service Tariff with the Federal Energy Regulatory Commission on Sept. 30, 2009. The tariff became effective on Dec. 1, 2009, as modified by Western's March 2, 2011 compliance filing. The revised tariff was developed to comply with FERC Order No. 890 and to be consistent with Western's statutory and regulatory requirements. It addresses changes in transmission services and planning. FERC issued an order on Dec. 2, 2010, granting Western's petition for a Declaratory Order approving the tariff as an acceptable reciprocity tariff, subject to Western making a compliance filing within 30 days to address items in Attachment C, Attachment P and Attachment Q. Western made its compliance filing on March 2, 2010, addressing FERC's Dec. 2, 2010, order. FERC accepted Western's March 2, 2011 compliance filing on April 25, 2011. Western has made several ministerial filings to its OATT as part of FERC's eTariff viewer system, the last of these was approved on March 29, 2013. Further detail can be found in the links below.Current OATT

307

Colorado/Transmission/Agencies | Open Energy Information  

Open Energy Info (EERE)

Agencies < Colorado | Transmission Jump to: navigation, search Colorado Transmission Roadmap Agency Links Local Regulations State Regulations Summary General Transmission...

308

National Electric Transmission Congestion Study Webinars | Department...  

Broader source: Energy.gov (indexed) [DOE]

National Electric Transmission Congestion Study National Electric Transmission Congestion Study Webinars National Electric Transmission Congestion Study Webinars The Department...

309

Transmission Planning | Department of Energy  

Office of Environmental Management (EM)

Planning Transmission Planning Modernizing America's electricity infrastructure is one of the U.S. Department of Energy's top priorities. The National Transmission Grid Study made...

310

Electricity Transmission, A Primer | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Transmission, A Primer Electricity Transmission, A Primer This primer on electric transmission is intended to help policymakers understand the physics of the transmission system,...

311

Disorder-Induced Microscopic Magnetic Memory  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Disorder-Induced Microscopic Magnetic Memory Print Disorder-Induced Microscopic Magnetic Memory Print The magnetic-recording industry deliberately introduces carefully controlled disorder into its materials to obtain the desired magnetic properties. But as the density of magnetic disks climbs, the size of the magnetic domains responsible for storage must decrease, posing new challenges. Beautiful theories based on random microscopic disorder have been developed over the past ten years. To directly compare these theories with precise experiments, an American-European team, led by researchers from the University of Washington, Seattle, first developed and then applied coherent x-ray speckle metrology to microscopic magnetic domains in a series of thin multilayer perpendicular magnetic materials of varying disorder. Their results, at odds with all previous theories, have set a new reference point for future theories.

312

Disorder-Induced Microscopic Magnetic Memory  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Disorder-Induced Microscopic Magnetic Memory Print Disorder-Induced Microscopic Magnetic Memory Print The magnetic-recording industry deliberately introduces carefully controlled disorder into its materials to obtain the desired magnetic properties. But as the density of magnetic disks climbs, the size of the magnetic domains responsible for storage must decrease, posing new challenges. Beautiful theories based on random microscopic disorder have been developed over the past ten years. To directly compare these theories with precise experiments, an American-European team, led by researchers from the University of Washington, Seattle, first developed and then applied coherent x-ray speckle metrology to microscopic magnetic domains in a series of thin multilayer perpendicular magnetic materials of varying disorder. Their results, at odds with all previous theories, have set a new reference point for future theories.

313

Variable Temperature Scanning Probe Microscope | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

EMSL's ultra-high vacuum, variable-temperature scanning probe microscope system, or UHV VT SPM, is a state-of-the-art surface science tool comprising multiple complementary...

314

Hybrid Transmission Corridor study  

SciTech Connect (OSTI)

Hybrid Transmission Corridors are areas where High Voltage Alternating Current (HVAC) transmission lines and High Voltage Direct Current (HVDC) transmission lines exist in close proximity of each other. Because of the acceptance of HVDC as a means of transporting electric power over long distances and the difficulties associated with obtaining new right-of-ways, HVDC lines may have to share the same transmission corridor with HVAC lines. The interactions between conductors energized with different types of voltages causes changes in the electrical stresses applied to the conductors and insulators. As a result, corona phenomena, field effects and insulation performance can be affected. This report presents the results of an investigation of the HVAC-HVDC interaction and its effect on corona and AC and DC electric field phenomena. The method of investigation was based on calculation methods developed at the EPRI High Voltage Transmission Research Center (HVTRC) and supported by the results of full and reduced-scale line tests. Also, a survey of existing hybrid corridors is given along with the results of measurements made at one of those corridors. A number of examples in which an existing AC corridor may be transformed into a hybrid corridor are discussed. The main result of the research is an analytical/empirical model for predicting the electrical/environmental performance of hybrid corridors, a definition of ACDC interaction and a set of criteria for specifying when the interaction becomes significant, and a set of design rules.

Clairmont, B.A.; Johnson, G.B.; Zaffanella, L.E. (General Electric Co., Lenox, MA (United States))

1992-06-01T23:59:59.000Z

315

X-ray laser microscope apparatus  

DOE Patents [OSTI]

A microscope consisting of an x-ray contact microscope and an optical microscope. The optical, phase contrast, microscope is used to align a target with respect to a source of soft x-rays. The source of soft x-rays preferably comprises an x-ray laser but could comprise a synchrotron or other pulse source of x-rays. Transparent resist material is used to support the target. The optical microscope is located on the opposite side of the transparent resist material from the target and is employed to align the target with respect to the anticipated soft x-ray laser beam. After alignment with the use of the optical microscope, the target is exposed to the soft x-ray laser beam. The x-ray sensitive transparent resist material whose chemical bonds are altered by the x-ray beam passing through the target mater GOVERNMENT LICENSE RIGHTS This invention was made with government support under Contract No. De-FG02-86ER13609 awarded by the Department of Energy. The Government has certain rights in this invention.

Suckewer, Szymon (Princeton, NJ); DiCicco, Darrell S. (Plainsboro, NJ); Hirschberg, Joseph G. (Coral Gables, FL); Meixler, Lewis D. (East Windsor, NJ); Sathre, Robert (Princeton, NJ); Skinner, Charles H. (Lawrenceville, NJ)

1990-01-01T23:59:59.000Z

316

Variable Temperature Ultra-High Vacuum Scanning Tunneling Microscope...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Vacuum Scanning Tunneling Microscope The Omicron variable temperature ultra-high vacuum (UHV) scanning tunneling microscope (VTSTM) is designed to study the structure of both clean...

317

Single-Molecule Flourescence/Patch Clamp Microscope | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Single-Molecule FlourescencePatch Clamp Microscope Single-Molecule FlourescencePatch Clamp Microscope At EMSL, researchers use the single-molecule fluorescencepatch clamp...

318

Highly charged ion based time of flight emission microscope  

DOE Patents [OSTI]

A highly charged ion based time-of-flight emission microscope has been designed, which improves the surface sensitivity of static SIMS measurements because of the higher ionization probability of highly charged ions. Slow, highly charged ions are produced in an electron beam ion trap and are directed to the sample surface. The sputtered secondary ions and electrons pass through a specially designed objective lens to a microchannel plate detector. This new instrument permits high surface sensitivity (10.sup.10 atoms/cm.sup.2), high spatial resolution (100 nm), and chemical structural information due to the high molecular ion yields. The high secondary ion yield permits coincidence counting, which can be used to enhance determination of chemical and topological structure and to correlate specific molecular species.

Barnes, Alan V. (Livermore, CA); Schenkel, Thomas (San Francisco, CA); Hamza, Alex V. (Livermore, CA); Schneider, Dieter H. (Livermore, CA); Doyle, Barney (Albuquerque, NM)

2001-01-01T23:59:59.000Z

319

transmission | OpenEI  

Open Energy Info (EERE)

transmission transmission Dataset Summary Description This dataset represents a historical repository of all the numerical data from the smartgrid.gov website condensed into spreadsheets to enable analysis of the data. Below are a couple of things worth noting: Source Smartgrid.gov Date Released March 04th, 2013 (9 months ago) Date Updated March 04th, 2013 (9 months ago) Keywords AMI costs distribution smart grid transmission Data application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon SmartGrid.gov Quarterly Data Summary 4Q12 (xlsx, 112.1 KiB) application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon SmartGrid.gov Quarterly Data Summary 3Q12 (xlsx, 107.9 KiB) application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon SmartGrid.gov Quarterly Data Summary 2Q12 (xlsx, 111.9 KiB)

320

NREL: Energy Analysis: Transmission Infrastructure  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission Infrastructure Transmission Infrastructure Grid expansion and planning to allow large scale deployment of renewable generation Large scale deployment of renewable electricity generation will require additional transmission to connect renewable resources, which are wide-spread across the US, but regionally-constrained, to load centers. Long-term transmission planning, based on potential future growth in electric loads and generation resource expansion options, is critical to maintaining the necessary flexibility required for a reliable and robust transmission system. NREL's analyses support transmission infrastructure planning and expansion to enable large-scale deployment of renewable energy in the future. NREL's transmission infrastructure expansion and planning analyses show

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Printed circuit dispersive transmission line  

DOE Patents [OSTI]

A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission line between two adjacent periodic intersections to be longer than the other. 5 figures.

Ikezi, H.; Lin-Liu, Y.R.; DeGrassie, J.S.

1991-08-27T23:59:59.000Z

322

Printed circuit dispersive transmission line  

DOE Patents [OSTI]

A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission line between two adjacent periodic intersections to be longer than the other.

Ikezi, Hiroyuki (Rancho Santa Fe, CA); Lin-Liu, Yuh-Ren (San Diego, CA); DeGrassie, John S. (Encinitas, CA)

1991-01-01T23:59:59.000Z

323

Transmission line capital costs  

SciTech Connect (OSTI)

The displacement or deferral of conventional AC transmission line installation is a key benefit associated with several technologies being developed with the support of the U.S. Department of Energy`s Office of Energy Management (OEM). Previous benefits assessments conducted within OEM have been based on significantly different assumptions for the average cost per mile of AC transmission line. In response to this uncertainty, an investigation of transmission line capital cost data was initiated. The objective of this study was to develop a database for preparing preliminary estimates of transmission line costs. An extensive search of potential data sources identified databases maintained by the Bonneville Power Administration (BPA) and the Western Area Power Administration (WAPA) as superior sources of transmission line cost data. The BPA and WAPA data were adjusted to a common basis and combined together. The composite database covers voltage levels from 13.8 to 765 W, with cost estimates for a given voltage level varying depending on conductor size, tower material type, tower frame type, and number of circuits. Reported transmission line costs vary significantly, even for a given voltage level. This can usually be explained by variation in the design factors noted above and variation in environmental and land (right-of-way) costs, which are extremely site-specific. Cost estimates prepared from the composite database were compared to cost data collected by the Federal Energy Regulatory Commission (FERC) for investor-owned utilities from across the United States. The comparison was hampered because the only design specifications included with the FERC data were voltage level and line length. Working within this limitation, the FERC data were not found to differ significantly from the composite database. Therefore, the composite database was judged to be a reasonable proxy for estimating national average costs.

Hughes, K.R.; Brown, D.R.

1995-05-01T23:59:59.000Z

324

Even-odd oscillation and valley polarization of transmission between multilayer graphenes  

SciTech Connect (OSTI)

Electron transmission through a boundary between multi-layer graphenes with Bernal stacking consisting of different number of layers is studied. A valley polarization in transmission probability appears as in monolayer and bilayer systems, exhibits considerable oscillation depending of even or odd layer numbers, and its amplitude gradually decreases with the layer number. The total transmission shows oscillation with much smaller amplitude.

Nakanishi, Takeshi [Nanosystem Research Institute, AIST, 1-1-1 Umezono, Tsukuba 305-8568 (Japan); Ando, Tsuneya [Department of Physics, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8551 (Japan)

2013-12-04T23:59:59.000Z

325

PHYSICAL REVIEW B 87, 144301 (2013) Parametric amplification in Josephson junction embedded transmission lines  

E-Print Network [OSTI]

transmission lines O. Yaakobi,1,* L. Friedland,2 C. Macklin,3 and I. Siddiqi3 1 INRS-EMT, 1650 Boul. Lionel; published 1 April 2013) An electronic transmission line that contains an array of nonlinear elements of the node flux along the transmission line is derived. It is shown that due to the nonlinearity

Friedland, Lazar

326

Enhanced Transmission Line Theory: Frequency-Dependent Line Parameters And Their Insertion in a  

E-Print Network [OSTI]

Enhanced Transmission Line Theory: Frequency- Dependent Line Parameters And Their Insertion in a Classical Transmission Line Equation Solver S. Chabane, P. Besnier IETR: Institute of Electronics--In this paper, a modified enhanced transmission- line theory taking into account higher-order modes is described

Paris-Sud XI, Université de

327

Electric Transmission System Workshop  

Broader source: Energy.gov (indexed) [DOE]

Lauren Azar Lauren Azar Senior Advisor to Secretary Chu November 2, 2012 Electric Transmission System Workshop We all have "visions," in one form or another: * Corporations call them strategic plans * RTOs ... transmission expansion plans or Order 1000 plans * State PUCs ... integrated resource plans * Employees ... career goals Visions for the Future Artist: Paolo Frattesi Artist: Paolo Frattesi Uncertainty = changing industry Changes in technology, threats and policies Can we make decisions in the face of change? .......How can we not? Can we agree on several key design attributes for the future grid? Taking Action in the Face of Uncertainty Step 1: Establish common ground on key design attributes GTT's Proposed Key Design Attributes:

328

10-Yr. Transmission Plan  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Power Marketing Rates Power Marketing Rates 10-Yr Transmission Plan 2012 Customer Meeting Announcement Agenda 120611 CRSP South Projects CRSP South PowerPoint Presentation CRSP South 2009-2011 Capitalized Execution CRSP North Projects CRSP North PowerPoint Presentation CRSP North 2009-2011 Capitalized Execution About Power Marketing Transmission Newsroom Business Policies Products Plan contents OASIS News features Careers No FEAR act Organization chart Plan processes Functions News releases Doing business Privacy policy History General power contract provisions OATT Revisions Fact sheets Energy Services Accessibility Financial information Rates and Repayment Interconnection Publications EPTC Adobe PDF Power projects EPAMP Infrastructure projects Federal Register Notices

329

Transmission SEAB Presentation  

Broader source: Energy.gov (indexed) [DOE]

Overcoming Overcoming Institutional Barriers to Infrastructure Development Lauren Azar Senior Advisor to the Secretary U.S. Department of Energy January 31, 2012 Lauren"s Initiatives 1. Rapid Response Team for Transmission 2. Power Marketing Administrations 3. Project Development in the Southwest 4. Congestion Study and NIETC Designations 5. Miscellaneous  EPA Regulations  Market Power

330

Continuously variable transmission  

SciTech Connect (OSTI)

This patent describes a power transmission apparatus. It comprises: a body, a pinion gear, a cam means, first and second gear rack pairs, preventing means;l first and second rack support means, a rotor mounted for rotation about a rotor axis, the rotor having rotor engaging means for engaging the rack support means so as to transmit power therebetween.

Irvin, P.J.E.

1992-07-14T23:59:59.000Z

331

Autonomous data transmission apparatus  

DOE Patents [OSTI]

A autonomous borehole data transmission apparatus for transmitting measurement data from measuring instruments at the downhole end of a drill string by generating pressure pulses utilizing a transducer longitudinally responsive to magnetic field pulses caused by electrical pulses corresponding to the measured downhole parameters.

Kotlyar, Oleg M. (4675 W. 3825 S, Salt Lake City, UT 84120)

1997-01-01T23:59:59.000Z

332

Borehole data transmission apparatus  

DOE Patents [OSTI]

A borehole data transmission apparatus is described whereby a centrifugal pump impeller(s) is used to provide a turbine stage having substantial pressure characteristics in response to changing rotational speed of a shaft for the pressure pulsing of data from the borehole through the drilling mud to the surface of the earth.

Kotlyar, O.M.

1993-03-23T23:59:59.000Z

333

Markov Random Field Based Automatic Image Alignment for ElectronTomography  

SciTech Connect (OSTI)

Cryo electron tomography (cryo-ET) is the primary method for obtaining 3D reconstructions of intact bacteria, viruses, and complex molecular machines ([7],[2]). It first flash freezes a specimen in a thin layer of ice, and then rotates the ice sheet in a transmission electron microscope (TEM) recording images of different projections through the sample. The resulting images are aligned and then back projected to form the desired 3-D model. The typical resolution of biological electron microscope is on the order of 1 nm per pixel which means that small imprecision in the microscope's stage or lenses can cause large alignment errors. To enable a high precision alignment, biologists add a small number of spherical gold beads to the sample before it is frozen. These beads generate high contrast dots in the image that can be tracked across projections. Each gold bead can be seen as a marker with a fixed location in 3D, which provides the reference points to bring all the images to a common frame as in the classical structure from motion problem. A high accuracy alignment is critical to obtain a high resolution tomogram (usually on the order of 5-15nm resolution). While some methods try to automate the task of tracking markers and aligning the images ([8],[4]), they require user intervention if the SNR of the image becomes too low. Unfortunately, cryogenic electron tomography (or cryo-ET) often has poor SNR, since the samples are relatively thick (for TEM) and the restricted electron dose usually results in projections with SNR under 0 dB. This paper shows that formulating this problem as a most-likely estimation task yields an approach that is able to automatically align with high precision cryo-ET datasets using inference in graphical models. This approach has been packaged into a publicly available software called RAPTOR-Robust Alignment and Projection estimation for Tomographic Reconstruction.

Moussavi, Farshid; Amat, Fernando; Comolli, Luis R.; Elidan, Gal; Downing, Kenneth H.; Horowitz, Mark

2007-11-30T23:59:59.000Z

334

Fast electron microscopy via compressive sensing  

DOE Patents [OSTI]

Various technologies described herein pertain to compressive sensing electron microscopy. A compressive sensing electron microscope includes a multi-beam generator and a detector. The multi-beam generator emits a sequence of electron patterns over time. Each of the electron patterns can include a plurality of electron beams, where the plurality of electron beams is configured to impart a spatially varying electron density on a sample. Further, the spatially varying electron density varies between each of the electron patterns in the sequence. Moreover, the detector collects signals respectively corresponding to interactions between the sample and each of the electron patterns in the sequence.

Larson, Kurt W; Anderson, Hyrum S; Wheeler, Jason W

2014-12-09T23:59:59.000Z

335

High energy-resolution electron energy-loss spectroscopy study of the electric structure of double-walled carbon nanotubes  

Science Journals Connector (OSTI)

......High energy-resolution electron energy-loss spectroscopy study of the...Egerton R F. (1986) Electron Energy-Loss Spectroscopy in the Electron Microscope , Plenum, New York. High energy-resolution electron energy-loss......

Yohei Sato; Masami Terauchi; Yahachi Saito; Riichiro Saito

2006-06-01T23:59:59.000Z

336

Regulations for Electric Transmission and Fuel Gas Transmission Lines Ten  

Broader source: Energy.gov (indexed) [DOE]

Electric Transmission and Fuel Gas Transmission Electric Transmission and Fuel Gas Transmission Lines Ten or More Miles Long (New York) Regulations for Electric Transmission and Fuel Gas Transmission Lines Ten or More Miles Long (New York) < Back Eligibility Commercial Fuel Distributor Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Tribal Government Utility Savings Category Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State New York Program Type Siting and Permitting Provider New York State Public Service Commission Any person who wishes to construct an electric or gas transmission line that is more than ten miles long must file documents describing the construction plans and potential land use and environmental impacts of the proposed transmission line. The regulations describe application and review

337

Transmission Developers Inc.  

Broader source: Energy.gov (indexed) [DOE]

% ~ % ~ Transmission Developers Inc. July 7, 2011 Mr. Anthony J. Como Director, Permitting and Siting Office ofElectricity Delivery and Energy Reliability (OE-20) U.S. Department of Energy 1000 Independence A venue SW, Room 8G-024 Washington, D.C. 20585 Subject: Champlain Hudson Power Express Project U.S. Department of Energy Presidential Permit Application PP-362 Dear Mr. Como: On January 25, 2010, Transmission Developers, Inc. ("TDI'' or "Applicants") submitted on behalf of Champlain Hudson Power Express, Inc. ("CHPEI") an application to the U.S. Department of Energy ("DOE") for a Presidential Permit and an amendment on August 5, 2010 (collectively, the "Application") in connection with the Champlain Hudson Power Express

338

Transmission Siting_071508.indd  

Broader source: Energy.gov (indexed) [DOE]

Coordinating Interstate Electric Coordinating Interstate Electric Transmission Siting: An Introduction to the Debate The National Council on Electricity Policy 2 DISCLAIMER: The National Council on Electricity Policy is funded by the U.S. Department of Energy and the U.S. Environmental Protection Agency. The views and opinions expressed herein are strictly those of the authors and may not necessarily agree with the positions of the National Council on Electricity Policy, its committ ee members or the organizations they represent, the National Council funders, or those who commented on the paper during its draft ing. ACKNOWLEDGMENTS Coordinating Interstate Electric Transmission Siting: An Introduction to the Debate was prepared with the fi nancial assistance of a grant from the U.S. Department of Energy (DOE) Offi ce of Electricity Delivery

339

Drill string transmission line  

DOE Patents [OSTI]

A transmission line assembly for transmitting information along a downhole tool comprising a pin end, a box end, and a central bore traveling between the pin end and the box end, is disclosed in one embodiment of the invention as including a protective conduit. A transmission line is routed through the protective conduit. The protective conduit is routed through the central bore and the ends of the protective conduit are routed through channels formed in the pin end and box end of the downhole tool. The protective conduit is elastically forced into a spiral or other non-linear path along the interior surface of the central bore by compressing the protective conduit to a length within the downhole tool shorter than the protective conduit.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David S. (Lehi, UT); Bradford, Kline (Orem, UT); Fox, Joe (Spanish Fork, UT)

2006-03-28T23:59:59.000Z

340

Patterns of Transmission Investment  

E-Print Network [OSTI]

long term performance contracts with a developer of an HVDC transmission link to expand “interconnection” capacity between TSOs with no or limited interconnections and with large sustained differences in prices. Merchant investments supported... truly separate AC networks. For example, by building HVDC inter-connectors between two separate networks, opportunities to increase trades of power from high price to low priced areas can be exploited. The HVDC link between the England and France...

Joskow, Paul

2006-03-14T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Boardman to Hemingway Transmission Project  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Improvement (CBPI) Customer Forum Energy Imbalance Market Generator Interconnection Reform Implementation Network Integration Transmission Service (NT Service) Network Open...

342

On simulating 3D fluorescent microscope images  

Science Journals Connector (OSTI)

In recent years many various biomedical image segmentation methods have appeared. Though typically presented to be successful the majority of them was not properly tested against ground truth images. The obvious way of testing the quality of new segmentation ... Keywords: convolution, fluorescent optical microscope, procedural texture, simulator, synthetic image

David Svoboda; Marek Kašík; Martin Maška; Jan Hubeny; Stanislav Stejskal; Michal Zimmermann

2007-08-01T23:59:59.000Z

343

Le microscope des mathmaticiens Tribune du Net  

E-Print Network [OSTI]

cette "tribune" Interactif ! Deux parties : 1 les TIC du chercheur TIC = Technologies de l'Information et de la Communication #12;Contenu de cette "tribune" Interactif ! Deux parties : 1 les TIC du chercheur TIC = Technologies de l'Information et de la Communication 2 ordinateur : le microscope des

Theyssier, Guillaume

344

SLAC All Access: X-ray Microscope  

ScienceCinema (OSTI)

SLAC physicists Johanna Nelson and Yijin Liu give a brief overview of the X-ray microscope at the Stanford Synchrotron Radiation Lightsource (SSRL) that is helping improve rechargeable-battery technology by letting researchers peek into the inner workings of batteries as they operate.

Nelson, Johanna; Liu, Yijin

2014-06-13T23:59:59.000Z

345

On the Microscopic Origin of Cholesteric Pitch  

E-Print Network [OSTI]

We present a microscopic analysis of the instability of the nematic phase to chirality when molecular chirality is introduced perturbatively. We show that previously neglected short-range biaxial correlations play a crucial role in determining the cholesteric pitch. We propose an order parameter which quantifies the chirality of a molecule.

A. B. Harris; Randall D. Kamien; T. C. Lubensky

1996-07-11T23:59:59.000Z

346

Free electron laser  

DOE Patents [OSTI]

A high gain, single-pass free electron laser formed of a high brilliance electron injector source, a linear accelerator which imparts high energy to the electron beam, and an undulator capable of extremely high magnetic fields, yet with a very short period. The electron injector source is the first stage (gap) of the linear accelerator or a radial line transformer driven by fast circular switch. The linear accelerator is formed of a plurality of accelerating gaps arranged in series. These gaps are energized in sequence by releasing a single pulse of energy which propagates simultaneously along a plurality of transmission lines, each of which feeds the gaps. The transmission lines are graduated in length so that pulse power is present at each gap as the accelerated electrons pass therethrough. The transmission lines for each gap are open circuited at their ends. The undualtor has a structure similar to the accelerator, except that the transmission lines for each gap are substantially short circuited at their ends, thus converting the electric field into magnetic field. A small amount of resistance is retained in order to generate a small electric field for replenishing the electron bunch with the energy lost as it traverses through the undulator structure.

Villa, Francesco (Alameda, CA)

1990-01-01T23:59:59.000Z

347

Transmission Line Circuit Alexander Glasser  

E-Print Network [OSTI]

Chaos in a Transmission Line Circuit Alexander Glasser Marshal Miller With... Prof. Edward Ott Prof times become shorter, circuit connections behave more and more like transmission lines. Theoretical(t) - Transmission Line (Zo, T) #12;5 Cf/Cr 1000 Vf Capacitance Voltage Cf Cr Model for Nonlinear Capacitor

Anlage, Steven

348

Reversible Hydrogen Storage Materials – Structure, Chemistry, and Electronic Structure  

SciTech Connect (OSTI)

To understand the processes involved in the uptake and release of hydrogen from candidate light-weight metal hydride storage systems, a combination of materials characterization techniques and first principle calculation methods have been employed. In addition to conventional microstructural characterization in the transmission electron microscope, which provides projected information about the through thickness microstructure, electron tomography methods were employed to determine the three-dimensional spatial distribution of catalyst species for select systems both before and after dehydrogenation. Catalyst species identification as well as compositional analysis of the storage material before and after hydrogen charging and discharging was performed using a combination of energy dispersive spectroscopy, EDS, and electron energy loss spectroscopy, EELS. The characterization effort was coupled with first-principles, electronic-structure and thermodynamic techniques to predict and assess meta-stable and stable phases, reaction pathways, and thermodynamic and kinetic barriers. Systems studied included:NaAlH4, CaH2/CaB6 and Ca(BH4)2, MgH2/MgB2, Ni-Catalyzed Magnesium Hydride, TiH2-Catalyzed Magnesium Hydride, LiBH4, Aluminum-based systems and Aluminum

Robertson, Ian M. [University of Wisconsin-Madison; Johnson, Duane D. [Ames Lab., Iowa

2014-06-21T23:59:59.000Z

349

NREL: Transmission Grid Integration - Transmission Planning and Analysis  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission Planning and Analysis Transmission Planning and Analysis Thumbnail of map the United States that shows wind resources and transmission lines. Enlarge image This map shows the location of wind resources and transmission lines in the United States. See a larger image or state maps. NREL researchers are engaged in transmission planning and analysis to strengthen the electric power system through the integration of solar and wind power. As demand for electricity increases, electric power system operators must plan for and construct new generation and transmission lines. However, variable generation such as solar and wind power plants are often located far from the loads they serve. They depend on transmission lines to transport the electricity they produce to load centers. NREL is working with industry and utilities to address issues related to

350

Faculty Position in Materials Electron Microscopy  

E-Print Network [OSTI]

Faculty Position in Materials Electron Microscopy at the Ecole Polytechnique Fédérale de Lausanne in electron microscopy of materials within its Institute of Materials. We seek exceptional individuals who community. Top-level applications are invited from candidates at the cutting edge of electron microscopic

Candea, George

351

Characterization of grain boundary conductivity of spin-sprayed ferrites using scanning microwave microscope  

SciTech Connect (OSTI)

Grain boundary electrical conductivity of ferrite materials has been characterized using scanning microwave microscope. Structural, electrical, and magnetic properties of Fe{sub 3}O{sub 4} spin-sprayed thin films onto glass substrates for different length of growth times were investigated using a scanning microwave microscope, an atomic force microscope, a four-point probe measurement, and a made in house transmission line based magnetic permeameter. The real part of the magnetic permeability shows almost constant between 10 and 300?MHz. As the Fe{sub 3}O{sub 4} film thickness increases, the grain size becomes larger, leading to a higher DC conductivity. However, the loss in the Fe{sub 3}O{sub 4} films at high frequency does not increase correspondingly. By measuring the reflection coefficient s{sub 11} from the scanning microwave microscope, it turns out that the grain boundaries of the Fe{sub 3}O{sub 4} films exhibit higher electric conductivity than the grains, which contributes loss at radio frequencies. This result will provide guidance for further improvement of low loss ferrite materials for high frequency applications.

Myers, J.; Nicodemus, T.; Zhuang, Y., E-mail: yan.zhuang@wright.edu [Department of Electrical Engineering, Wright State University, Dayton, Ohio 45435 (United States); Watanabe, T.; Matsushita, N. [Materials and Structures Laboratory, Tokyo Institute of Technology, Yokohama (Japan); Yamaguchi, M. [Department of Electrical Engineering, Tohoku University, Sendai 980-8579 (Japan)

2014-05-07T23:59:59.000Z

352

Continuous-wave laser annealing of Si-rich oxide: A microscopic picture of macroscopic Si-SiO{sub 2} phase separation  

SciTech Connect (OSTI)

We report on the first observation of the macroscopic (long-range) Si-SiO{sub 2} phase separation in Si-rich oxide SiO{sub x}(x<2) obtained by continuous-wave laser annealing of free-standing SiO{sub x} films. The effect is analyzed by a unique combination of microscopic methods (Raman, transmission, photoluminescence, and infrared spectroscopy, transmission electron microscopy, electron energy loss spectroscopy, and x-ray photoelectron spectroscopy). Three regions can be distinguished on a SiO{sub x} free-standing film after 488 nm laser annealing at intensities above {approx}10{sup 4} W cm{sup -2}: central spot, ring around the central spot, and pristine film outside the irradiated area. In the pristine SiO{sub x} material, small Si nanocrystals (Si-nc) (diameters of a few nanometer) are surrounded by SiO{sub 2} with an addition of residual suboxides, the Si-nc being produced by annealing at 1100 deg. C in a furnace. The central spot of the laser-annealed area (up to {approx}30 {mu}m wide in these experiments) is practically free of Si excess and mainly consists of amorphous SiO{sub 2}. The ring around the central spot contains large spherical Si-nc (diameters up to {approx}100 nm) embedded in amorphous SiO{sub 2} without the presence of suboxides. Laser-induced temperatures in the structurally modified regions presumably exceed the Si melting temperature. The macroscopic Si-SiO{sub 2} phase separation is connected with extensive diffusion in temperature gradient leading to the Si concentration gradient. The present work demonstrates the advantages of high spatial resolution for analysis in materials research.

Khriachtchev, Leonid; Nikitin, Timur; Raesaenen, Markku; Domanskaya, Alexandra [Laboratory of Physical Chemistry, University of Helsinki, P.O. Box 55, FIN-00014 (Finland); Boninelli, Simona; Iacona, Fabio [MATIS IMM CNR, Via Santa Sofia 64, I-95123 Catania (Italy); Engdahl, Anders [MAX-lab, Lund University, P.O. Box 118, 22100 Lund (Sweden); Juhanoja, Jyrki [Top Analytica, Ruukinkatu 4, FIN-20540 Turku (Finland); Novikov, Sergei [Electron Physics Laboratory, Aalto University, P.O. Box 3000, FIN-02015 HUT (Finland)

2010-12-15T23:59:59.000Z

353

Optical data transmission at the superconducting super collider  

SciTech Connect (OSTI)

Digital and analog data transmissions via fiber optics for the Superconducting Super Collider have been investigated. The state of the art of optical transmitters, low loss fiber waveguides, receivers and associated electronics components are reviewed and summarized. Emphasis is placed on the effects of the radiation environment on the performance of an optical data transmission system components. Also, the performance of candidate components of the wide band digital and analog transmission systems intended for deployment of the Superconducting Super Collider Detector is discussed. 27 refs., 15 figs.

Leskovar, B.

1989-02-01T23:59:59.000Z

354

Transmission/Photo Gallery | Open Energy Information  

Open Energy Info (EERE)

Colorado transmission 2.jpg Bird diverters.jpg Transmission insulators.jpg Retrieved from "http:en.openei.orgwindex.php?titleTransmissionPhotoGallery&oldid687595...

355

The Potential for Bayesian Compressive Sensing to Significantly Reduce Electron Dose in High Resolution STEM Images  

SciTech Connect (OSTI)

The use of high resolution imaging methods in the scanning transmission electron microscope (STEM) is limited in many cases by the sensitivity of the sample to the beam and the onset of electron beam damage (for example in the study of organic systems, in tomography and during in-situ experiments). To demonstrate that alternative strategies for image acquisition can help alleviate this beam damage issue, here we apply compressive sensing via Bayesian dictionary learning to high resolution STEM images. These experiments successively reduce the number of pixels in the image (thereby reducing the overall dose while maintaining the high resolution information) and show promising results for reconstructing images from this reduced set of randomly collected measurements. We show that this approach is valid for both atomic resolution images and nanometer resolution studies, such as those that might be used in tomography datasets, by applying the method to images of strontium titanate and zeolites. As STEM images are acquired pixel by pixel while the beam is scanned over the surface of the sample, these post acquisition manipulations of the images can, in principle, be directly implemented as a low-dose acquisition method with no change in the electron optics or alignment of the microscope itself.

Stevens, Andrew J.; Yang, Hao; Carin, Lawrence; Arslan, Ilke; Browning, Nigel D.

2014-02-11T23:59:59.000Z

356

NREL: Transmission Grid Integration - Publications  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Publications Publications Want updates about future transmission grid integration webinars and publications? Join our mailing list. NREL has an extensive collection of publications related to transmission integration research. Explore the resources below to learn more. Selected Project Publications Read selected publications related to these transmission integration projects: Western Wind and Solar Integration Study Eastern Renewable Generation Integration Study Oahu Wind Integration and Transmission Study Flexible Energy Scheduling Tool for Integration of Variable generation (FESTIV) Active power controls Forecasting Grid Simulation. NREL Publications Database NREL's publications database offers a variety of documents related to transmission integration that were written by NREL staff and

357

Electric Transmission Line Siting Compact  

Broader source: Energy.gov (indexed) [DOE]

Electric Transmission Line Siting Compact Electric Transmission Line Siting Compact 1 ______________________________________________________________________________ 2 ARTICLE I 3 PURPOSE 4 5 Siting electric transmission lines across state borders and federal lands is an issue for states, the 6 federal government, transmission utilities, consumers, environmentalists, and other stakeholders. 7 The current, multi-year application review process by separate and equal jurisdictions constitutes 8 a sometimes inefficient and redundant process for transmission companies and complicates the 9 efforts of state and federal policy-makers and other stakeholders to develop more robust 10 economic opportunities, increase grid reliability and security, and ensure the consumers have the 11 lowest cost electricity possible. 12

358

Development of x-ray laminography under an x-ray microscopic condition  

SciTech Connect (OSTI)

An x-ray laminography system under an x-ray microscopic condition was developed to obtain a three-dimensional structure of laterally-extended planar objects which were difficult to observe by x-ray tomography. An x-ray laminography technique was introduced to an x-ray transmission microscope with zone plate optics. Three prototype sample holders were evaluated for x-ray imaging laminography. Layered copper grid sheets were imaged as a laminated sample. Diatomite powder on a silicon nitride membrane was measured to confirm the applicability of this method to non-planar micro-specimens placed on the membrane. The three-dimensional information of diatom shells on the membrane was obtained at a spatial resolution of sub-micron. Images of biological cells on the membrane were also obtained by using a Zernike phase contrast technique.

Hoshino, Masato; Uesugi, Kentaro; Takeuchi, Akihisa; Suzuki, Yoshio; Yagi, Naoto [Japan Synchrotron Radiation Research Institute JASRI/SPring-8, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

2011-07-15T23:59:59.000Z

359

Transmission Workshop | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

DOE Grid Tech Team » Activities/Outreach » GTT DOE Grid Tech Team » Activities/Outreach » GTT Activities » Transmission Workshop Transmission Workshop Transmission Workshop GTT Transmission Workshop - November 1-2, 2012 On November 1-2, 2012, the GTT presented a workshop on grid integration on the transmission system at the DoubleTree Crystal City near Washington, DC. A draft of the DOE Action Plan Addressing the Electricity Transmission System was discussed during the workshop, which addressed the challenges and opportunities presented by the integration of 21st century energy technologies into the electricity transmission system. Parallel sessions addressed the challenges and opportunities of modernizing the grid and drilled down into key technology areas associated with each of these: System visibility: what advances are needed to "see" the state of

360

Terahertz Quantum-Cascade Transmission-Line Metamaterials  

E-Print Network [OSTI]

Terahertz Transmission-Line Metamaterials . . . . . . .CRLH Transmission Lines . . . . . . . . . . . . . . . .Terahertz CRLH Transmission-Line Metamaterials . . . . . . .

Tavallaee, Amir Ali

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Abstract --Under a context of transmission open access, a methodology to define a common transmission trunk system  

E-Print Network [OSTI]

Terms--Transmission systems, Transmission pricing, Cooperative games, Shapley value, Transmission open

Catholic University of Chile (Universidad Católica de Chile)

362

A review of the NRL CARS microscope  

Science Journals Connector (OSTI)

This paper describes a technique that permits molecular specificity in microscopy while retaining good spatial resolution. Specificity is achieved using Raman scattering from characteristic molecular vibrations and high resolution is obtained by imaging the distribution of visible anti?Stokes radiation. Images have been obtained from a variety of pure organic liquids from deuterated water in onion?skin cells deuterated liposomes and other samples. Thermal and dielectric breakdown damage to even fragile biological materials is made negligible by choice of duty cycle and average power. Sample fluorescence is avoided by the choice of anti?Stokes imaging. Imaging through (usually astigmatic) spectrometers is not needed. Deuterium substitution can be used as a general purpose and artifact?free ‘‘stain’’. The combination of high spatial resolution excellent molecular discrimination and digital image processing (background subtraction) provide the CARS microscope with capabilities not found in any other current microscopic imaging technique.

M. D. Duncan; J. Reintjes; T. J. Manuccia

1987-01-01T23:59:59.000Z

363

The Cost of Transmission for Wind Energy: A Review of Transmission Planning Studies  

E-Print Network [OSTI]

Equipment Transmission Lines 765 kV (no description) 500Montana-Alberta Tie 230 kV Transmission Line: TransmissionMontana-Alberta Tie 230 kV Transmission Line: Transmission

Mills, Andrew D.

2009-01-01T23:59:59.000Z

364

National Electric Transmission Congestion Study: Preliminary...  

Broader source: Energy.gov (indexed) [DOE]

National Electric Transmission Congestion Study: Preliminary Findings National Electric Transmission Congestion Study: Preliminary Findings The Department hosted three webinars in...

365

Hydrogen Delivery Technologies and Systems - Pipeline Transmission...  

Broader source: Energy.gov (indexed) [DOE]

Hydrogen Delivery Technologies and Systems - Pipeline Transmission of Hydrogen Hydrogen Delivery Technologies and Systems - Pipeline Transmission of Hydrogen Hydrogen Delivery...

366

Dynamic study of tunable stiffness scanning microscope probe  

E-Print Network [OSTI]

This study examines the dynamic characteristics of the in-plane tunable stiffness scanning microscope probe for an atomic force microscope (AFM). The analysis was carried out using finite element analysis (FEA) methods for ...

Vega González, Myraida Angélica

2005-01-01T23:59:59.000Z

367

AGENDA: PETROLEUM PRODUCT TRANSMISSION & DISTRIBUTION  

Broader source: Energy.gov [DOE]

The agenda for the Quadrennial Energy Review (QER) public stakeholder meeting in New Orleans on petroleum product transmission, distribution, and storage.

368

Transmission Reliability | Department of Energy  

Energy Savers [EERE]

design, long-term supply and transmission investment, renewable integration, demand response, and environmental impacts. Researchers use models and simulations to assess how...

369

NREL: Transmission Grid Integration - Projects  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Projects NREL's transmission integration projects provide data and models that help utilities and policymakers make informed decisions about the integration of variable generation,...

370

Chapter 4 Transmission Adequacy | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Chapter 4 Transmission Adequacy Chapter 4 Transmission Adequacy Chapter 4 Transmission Adequacy Transmission lines are the critical link between the point of electricity generation and consumers. The U.S. transmission grid infrastructure is owned and operated by approximately 3,000 distribution utilities and 500 transmission owners. This structure presents a distinct set of challenges in transmission planning, siting, cost allocation, grid operations and management, technological innovation, financing and construction. The development and deployment of a national strategy on transmission that meets the needs of all parties is extremely complex; however, a solution is desperately needed. Chapter 4 Transmission Adequacy More Documents & Publications Draft Chapter 4: Transmission Adequacy

371

Scanning tip microwave near field microscope  

DOE Patents [OSTI]

A microwave near field microscope has a novel microwave probe structure wherein the probing field of evanescent radiation is emitted from a sharpened metal tip instead of an aperture or gap. This sharpened tip, which is electrically and mechanically connected to a central electrode, extends through and beyond an aperture in an endwall of a microwave resonating device such as a microwave cavity resonator or a microwave stripline resonator. Since the field intensity at the tip increases as the tip sharpens, the total energy which is radiated from the tip and absorbed by the sample increases as the tip sharpens. The result is improved spatial resolution without sacrificing sensitivity.

Xiang, Xiao-Dong (Alameda, CA); Schultz, Peter G. (Oakland, CA); Wei, Tao (Albany, CA)

1998-01-01T23:59:59.000Z

372

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

SciTech Connect (OSTI)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

Yashiro, Wataru; Momose, Atsushi [Department of Advanced Materials Science, Graduate School of Frontier Sciences, University of Tokyo, 5-1-5, Kashiwanoha, Kashiwa, Chiba, 277-8561 (Japan); Takeuchi, Akihisa; Suzuki, Yoshio [Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1, Kouto, Sayo-cho, Sayo-gun, Hyogo, 679-5198 (Japan)

2010-06-23T23:59:59.000Z

373

HVDC power transmission technology assessment  

SciTech Connect (OSTI)

The purpose of this study was to develop an assessment of the national utility system`s needs for electric transmission during the period 1995-2020 that could be met by future reduced-cost HVDC systems. The assessment was to include an economic evaluation of HVDC as a means for meeting those needs as well as a comparison with competing technologies such as ac transmission with and without Flexible AC Transmission System (FACTS) controllers. The role of force commutated dc converters was to be assumed where appropriate. The assessment begins by identifying the general needs for transmission in the U.S. in the context of a future deregulated power industry. The possible roles for direct current transmission are then postulated in terms of representative scenarios. A few of the scenarios are illustrated with the help of actual U.S. system examples. non-traditional applications as well as traditional applications such as long lines and asynchronous interconnections are discussed. The classical ``break-even distance`` concept for comparing HVDC and ac lines is used to assess the selected scenarios. The impact of reduced-cost converters is reflected in terms of the break-even distance. This report presents a comprehensive review of the functional benefits of HVDC transmission and updated cost data for both ac and dc system components. It also provides some provocative thoughts on how direct current transmission might be applied to better utilize and expand our nation`s increasingly stressed transmission assets.

Hauth, R.L.; Tatro, P.J.; Railing, B.D. [New England Power Service Co., Westborough, MA (United States); Johnson, B.K.; Stewart, J.R. [Power Technologies, Inc., Schenectady, NY (United States); Fink, J.L.

1997-04-01T23:59:59.000Z

374

Hydrogen Transmission and Distribution Workshop  

Broader source: Energy.gov [DOE]

Proceedings from the Hydrogen Transmission and Distribution Workshop held February 25-26, 2014, in Golden, Colorado. The objective was to discuss and share information on the research, development, and demonstration needs and challenges for low-cost, effective hydrogen transmission and distribution from centralized production facilities to the point of use.

375

Direct current power transmission systems  

SciTech Connect (OSTI)

This book represents text on HVDC transmission available. It deals with the various aspects of the state of the art in HVDC transmission technology. This book presents many aspects of interactions of AC/DC systems. Modeling and analysis of DC systems are also discussed in detail.

Padiyar, K.R.

1991-01-01T23:59:59.000Z

376

An all-cryogenic THz transmission spectrometer P. J. Burkea)  

E-Print Network [OSTI]

An all-cryogenic THz transmission spectrometer P. J. Burkea) and J. P. Eisenstein Condensed Matter contained in a cryogenic environment. Cyclotron emission from a two-dimensional electron gas 2DEG heated microwave to optical frequencies.2 In this article an all-cryogenic spectrometer is presented that bypasses

Eisenstein, Jim

377

Transmission Reliability | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission Reliability Transmission Reliability Transmission Reliability Modernizing America's electricity infrastructure is one of the U.S. Department of Energy's top priorities. The DOE Strategic Plan states that today's electric grid needs to be more efficient, reliable, and secure. A modern, smarter electric grid may save consumers money, help our economy run more efficiently, allow rapid growth in renewable energy sources, and enhance energy reliability. The Department's research into a variety of tools that will improve advanced system monitoring, visualization, control, operations, and market structure will ultimately modernize the electricity transmission infrastructure to ease congestion, allow for increases in demand, and provide a greater degree of security. The Transmission Reliability Program is aligned with this strategic plan

378

ITC Transmission | Open Energy Information  

Open Energy Info (EERE)

ITC Transmission ITC Transmission Jump to: navigation, search Name ITC Transmission Place Michigan Utility Id 56068 Utility Location Yes Ownership T NERC RFC Yes ISO MISO Yes Activity Transmission Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=ITC_Transmission&oldid=410858" Categories: EIA Utility Companies and Aliases Utility

379

Regional Transmission Projects: Finding Solutions  

SciTech Connect (OSTI)

The Keystone Center convened and facilitated a year-long Dialogue on "Regional Transmission Projects: Finding Solutions" to develop recommendations that will help address the difficult and contentious issues related to expansions of regional electric transmission systems that are needed for reliable and economic transmission of power within and across regions. This effort brought together a cross-section of affected stakeholders and thought leaders to address the problem with the collective wisdom of their experience and interests. Transmission owners sat at the table with consumer advocates and environmental organizations. Representatives from regional transmission organizations exchanged ideas with state and federal regulators. Generation developers explored common interests with public power suppliers. Together, the Dialogue participants developed consensus solutions about how to begin unraveling some of the more intractable issues surrounding identification of need, allocation of costs, and reaching consensus on siting issues that can frustrate the development of regional transmission infrastructure. The recommendations fall into three broad categories: 1. Recommendations on appropriate institutional arrangements and processes for achieving regional consensus on the need for new or expanded transmission infrastructure 2. Recommendations on the process for siting of transmission lines 3. Recommendations on the tools needed to support regional planning, cost allocation, and siting efforts. List of Dialogue participants: List of Dialogue Participants: American Electric Power American Transmission Company American Wind Energy Association California ISO Calpine Corporation Cinergy Edison Electric Institute Environmental Defense Federal Energy Regulatory Commission Great River Energy International Transmission Company ISO-New England Iowa Public Utility Board Kanner & Associates Midwest ISO National Association of Regulatory Utility Commissioners National Association of State Utility Consumer Advocates National Grid Northeast Utilities PA Office of Consumer Advocates Pacific Gas & Electric Corporation Pennsylvania Public Utility Commission PJM Interconnection The Electricity Consumers Resource Council U.S. Department of Energy US Department of the Interior Van Ness Feldman Western Interstate Energy Board Wind on the Wires Wisconsin Public Service Commission Xcel Energy

The Keystone Center

2005-06-15T23:59:59.000Z

380

Fact #850: December 8, 2014 Automatic Transmissions have closed the Fuel Economy Gap with Manual Transmissions  

Broader source: Energy.gov [DOE]

Historically, manual transmissions have delivered better fuel economy than automatic transmissions. However, improvements in the efficiency of automatic transmissions have closed that gap in recent...

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Measuring charge trap occupation and energy level in CdSe/ZnS quantum dots using a scanning tunneling microscope  

E-Print Network [OSTI]

We use a scanning tunneling microscope to probe single-electron charging phenomena in individual CdSe/ZnS (core/shell) quantum dots (QDs) at room temperature. The QDs are deposited on top of a bare Au thin film and form a ...

Bulovic, Vladimir

382

Scanning tunneling microscope tip as a positionable contact: Probing a Josephson-junction array at subkelvin temperatures  

E-Print Network [OSTI]

Scanning tunneling microscope tip as a positionable contact: Probing a Josephson-junction arrayK. The STM enables us to probe the structure, a Josephson-junction array, at various positions. Examples of such systems are two- dimensional electron gases and Josephson junction arrays.1

383

Microscopic model of critical current noise in Josephson-junction qubits: Subgap resonances and Andreev bound states  

E-Print Network [OSTI]

Microscopic model of critical current noise in Josephson-junction qubits: Subgap resonances in Josephson junctions based on individual trapping centers in the tunnel-barrier hybridized with electrons microresonators observed in Josephson-junction qubits R. W. Simmonds et al., Phys. Rev. Lett. 93, 077003 2004

von Delft, Jan

384

Energy Transmission and Infrastructure  

SciTech Connect (OSTI)

The objective of Energy Transmission and Infrastructure Northern Ohio (OH) was to lay the conceptual and analytical foundation for an energy economy in northern Ohio that will: • improve the efficiency with which energy is used in the residential, commercial, industrial, agricultural, and transportation sectors for Oberlin, Ohio as a district-wide model for Congressional District OH-09; • identify the potential to deploy wind and solar technologies and the most effective configuration for the regional energy system (i.e., the ratio of distributed or centralized power generation); • analyze the potential within the district to utilize farm wastes to produce biofuels; • enhance long-term energy security by identifying ways to deploy local resources and building Ohio-based enterprises; • identify the policy, regulatory, and financial barriers impeding development of a new energy system; and • improve energy infrastructure within Congressional District OH-09. This objective of laying the foundation for a renewable energy system in Ohio was achieved through four primary areas of activity: 1. district-wide energy infrastructure assessments and alternative-energy transmission studies; 2. energy infrastructure improvement projects undertaken by American Municipal Power (AMP) affiliates in the northern Ohio communities of Elmore, Oak Harbor, and Wellington; 3. Oberlin, OH-area energy assessment initiatives; and 4. a district-wide conference held in September 2011 to disseminate year-one findings. The grant supported 17 research studies by leading energy, policy, and financial specialists, including studies on: current energy use in the district and the Oberlin area; regional potential for energy generation from renewable sources such as solar power, wind, and farm-waste; energy and transportation strategies for transitioning the City of Oberlin entirely to renewable resources and considering pedestrians, bicyclists, and public transportation as well as drivers in developing transportation policies; energy audits and efficiency studies for Oberlin-area businesses and Oberlin College; identification of barriers to residential energy efficiency and development of programming to remove these barriers; mapping of the solar-photovoltaic and wind-energy supply chains in northwest Ohio; and opportunities for vehicle sharing and collaboration among the ten organizations in Lorain County from the private, government, non-profit, and educational sectors. With non-grant funds, organizations have begun or completed projects that drew on the findings of the studies, including: creation of a residential energy-efficiency program for the Oberlin community; installation of energy-efficient lighting in Oberlin College facilities; and development by the City of Oberlin and Oberlin College of a 2.27 megawatt solar photovoltaic facility that is expected to produce 3,000 megawatt-hours of renewable energy annually, 12% of the College’s yearly power needs. Implementation of these and other projects is evidence of the economic feasibility and technical effectiveness of grant-supported studies, and additional projects are expected to advance to implementation in the coming years. The public has benefited through improved energydelivery systems and reduced energy use for street lighting in Elmore, Oak Harbor, and Wellington; new opportunities for assistance and incentives for residential energy efficiency in the Oberlin community; new opportunities for financial and energy savings through vehicle collaboration within Lorain County; and decreased reliance on fossil fuels and expanded production of renewable energy in the region. The dissemination conference and the summary report developed for the conference also benefited the public, but making the findings and recommendations of the regional studies broadly available to elected officials, city managers, educators, representatives of the private sector, and the general public.

Mathison, Jane

2012-12-31T23:59:59.000Z

385

Full-field Transmission X-ray Microscopy | Stanford Synchrotron Radiation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

BL6-2c / Transmission X-ray Microscopy BL6-2c / Transmission X-ray Microscopy Home Researchers Publications Science Highlights Department of Energy Office of Science Search form Search Search TXM Search Full-field Transmission X-ray Microscopy Capabilities Full-field TXM is an excellent method to examine nanoscale heterogeneties in many materials, including complex hierarchical systems such as catalysts, fuel cells and battery electrodes, and biological and environmental samples, at 30 nm resolution.The transmission X-ray microscope (TXM) on beam line 6-2c at SSRL is capable of 2D imaging and tomography, as well as spectroscopic imaging for 2D and 3D elemental mapping and chemical mapping over tens of microns (up to mm in 2D). The field of view (FOV) is 30 microns, but mosaic images can be collected to

386

Testing of the Data Transmission System Monika Grothe, Ariane Frey, Massimiliano Turri, Max Wilder  

E-Print Network [OSTI]

Testing of the Data Transmission System Components Monika Grothe, Ariane Frey, Massimiliano Turri August 1999 Abstract This note provides a description of the set­up for testing the data transmission system electronics for the BaBar Silicon Vertex Tracker. #12; Contents 1 List of tested Components 3 2

California at Santa Cruz, University of

387

Development of a combined interference microscope objective and scanning probe microscope  

Science Journals Connector (OSTI)

A compact sensor head combining optical interference and scanning probe microscopy in a single instrument has been developed. This instrument is able to perform complementary quantitative measurements combining fast nondestructive three-dimensional surface analysis with high lateral resolution imaging. A custom interference microscopesensor head has been designed as the optical microscope objective and integrated within the architecture of a commercial interference microscope. The combined instrument makes available both the acquisition software and the hardware interface of the commercial microscope. The latter is able to function as a phase-shift interferometer or white light interferometer. Furthermore the use of an optical fiber to transmit light from an external laser: (i) removes a major heat source from the measurement environment and (ii) makes aperture correction unnecessary. The lateral resolution of the instrument has been extended by the addition of a previously developed compact scanning probe microscope(SPM) module to the custom interference microscope objective. This SPM unit is based upon piezoresistive cantilever technology. The “piezolevers” are self-sensing and therefore require no additional systems such as optical beam deflection or fiber interferometry to monitor their displacement. The mechanical simplicity of the piezolever SPM unit allows for a small physical size and can thus be added to the custom optical sensor head without violating constraints on the working distance defined by the optics. A major benefit of the system in terms of a quantitative nanometrology is the possibility to perform a traceable and direct calibration of the SPM module. This calibration is achieved practically by measuring an appropriate sample at a common location using both techniques. Results are presented here for the measurement of two calibration standards and a test sample to demonstrate the increased lateral resolution of the instrument.

James W. G. Tyrrell; Claudio Dal Savio; Rolf Krüger-Sehm; Hans-Ulrich Danzebrink

2004-01-01T23:59:59.000Z

388

Bibliography on transmission access issues  

SciTech Connect (OSTI)

This paper presents a bibliography on issues related to transmission access in electric power systems. There are 233 citations referenced in this bibliography. This bibliography presents a collection of selected literature on issues related to transmission access. It does not contain all of the material available on this subject or the categories contained herein. Some readers may feel that citations within this bibliography should be strictly limited to transmission system issues and not include energy pricing or reliability issues. However, it was the decision of the Subcommittee of the IEEE Task Force on Transmission Access and Nonutility Generation that selected entries relating to reliability and energy pricing, most relevant to transmission access, should be included. This decision was made because certain issues relating to reliability, transmission and energy pricing are perceived by the industry to be critical in the discussion of transmission access. The bibliography has been divided into the following sections or sub-sections: 2.0 Operational (Engineering) Issues, 3.0 Planning, 4.0 Reliability, 5.1 Economics: Costing, 5.2(a) Economics: Location-Differentiated Pricing, 5.2(b) Economics: Time-Differentiated Pricing, 5.3 Economics: Brokering, Bidding, and Auctioning, 6.0 Regulatory, and 7.0 General. Although the content of many publications spanned two or more of these sections, the desire to limit document length required that all publications be placed in the single most appropriate section. Publications are sorted according to author or publication resource.

Lankford, C.B. [Oklahoma Gas and Electric Co., Oklahoma City, OK (United States)] [Oklahoma Gas and Electric Co., Oklahoma City, OK (United States); McCalley, J.D. [Iowa State Univ., Ames, IA (United States)] [Iowa State Univ., Ames, IA (United States); Saini, N.K. [Entergy Services Corp., Metairie, LA (United States)] [Entergy Services Corp., Metairie, LA (United States)

1996-02-01T23:59:59.000Z

389

Polarizer with Nonrectangular Grooves in the HE11 Mode Transmission Line  

Science Journals Connector (OSTI)

This paper presents experimental results on polarizers with nonrectangular grooves to be used in high power millimeter wave transmission lines for electron cyclotron heating (ECH) of fusion plasmas. A low-powe...

K. Nagasaki; Y. Itoh; H. Morioka; T. Obiki

1999-05-01T23:59:59.000Z

390

Electrical transmission line diametrical retainer  

DOE Patents [OSTI]

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within down hole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to with stand the tension and compression of drill pipe during routine drilling cycles.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David (Lehi, UT); Dahlgren, Scott (Provo, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT); Fox, Joe (Spanish Fork, UT)

2004-12-14T23:59:59.000Z

391

Experimental investigations and three-dimensional transmission line matrix simulation of Ca 5 ? x A x B 2 Ti O 12 ( A = Mg , Zn, Ni, and Co; B = Nb and Ta) ceramic resonators  

Science Journals Connector (OSTI)

Temperature-stable low-loss Ca 5 ? x A x B 2 Ti O 12 ( A = Mg Zn Ni and Co; B = Nb and Ta)dielectrics suitable for microwave telecommunication applications were prepared by the conventional solid-state ceramic route. Investigations were made on the structure and microstructure of the ceramics employing x-ray and scanning electron microscopic techniques. The dielectric properties were measured in the 3.5 – 7 GHz frequency range. The time domain simulation of electromagnetic wave interaction with dielectric materials using three-dimensional transmission line matrix modeling methods is presented. Excellent agreement between experimental and simulated values of microwavedielectric properties was observed. The materials are potential candidates for applications in filters oscillators and high efficiency low-loss dielectric antennas working especially at millimeter wave region.

Pazhoor Varghese Bijumon; Mailadil Thomas Sebastian; Pezholil Mohanan

2005-01-01T23:59:59.000Z

392

Long working distance incoherent interference microscope  

DOE Patents [OSTI]

A full-field imaging, long working distance, incoherent interference microscope suitable for three-dimensional imaging and metrology of MEMS devices and test structures on a standard microelectronics probe station. A long working distance greater than 10 mm allows standard probes or probe cards to be used. This enables nanometer-scale 3-dimensional height profiles of MEMS test structures to be acquired across an entire wafer while being actively probed, and, optionally, through a transparent window. An optically identical pair of sample and reference arm objectives is not required, which reduces the overall system cost, and also the cost and time required to change sample magnifications. Using a LED source, high magnification (e.g., 50.times.) can be obtained having excellent image quality, straight fringes, and high fringe contrast.

Sinclair, Michael B. (Albuquerque, NM); De Boer, Maarten P. (Albuquerque, NM)

2006-04-25T23:59:59.000Z

393

Three-dimensional scanning confocal laser microscope  

DOE Patents [OSTI]

A confocal microscope for generating an image of a sample includes a first scanning element for scanning a light beam along a first axis, and a second scanning element for scanning the light beam at a predetermined amplitude along a second axis perpendicular to the first axis. A third scanning element scans the light beam at a predetermined amplitude along a third axis perpendicular to an imaging plane defined by the first and second axes. The second and third scanning element are synchronized to scan at the same frequency. The second and third predetermined amplitudes are percentages of their maximum amplitudes. A selector determines the second and third predetermined amplitudes such that the sum of the percentages is equal to one-hundred percent.

Anderson, R. Rox (Lexington, MA); Webb, Robert H. (Lincoln, MA); Rajadhyaksha, Milind (Charlestown, MA)

1999-01-01T23:59:59.000Z

394

Microscopic study of Ca$+$Ca fusion  

E-Print Network [OSTI]

We investigate the fusion barriers for reactions involving Ca isotopes $\\mathrm{^{40}Ca}+\\mathrm{^{40}Ca}$, $\\mathrm{^{40}Ca}+\\mathrm{^{48}Ca}$, and $\\mathrm{^{48}Ca}+\\mathrm{^{48}Ca}$ using the microscopic time-dependent Hartree-Fock theory coupled with a density constraint. In this formalism the fusion barriers are directly obtained from TDHF dynamics. We also study the excitation of the pre-equilibrium GDR for the $\\mathrm{^{40}Ca}+\\mathrm{^{48}Ca}$ system and the associated $\\gamma$-ray emission spectrum. Fusion cross-sections are calculated using the incoming-wave boundary condition approach. We examine the dependence of fusion barriers on collision energy as well as on the different parametrizations of the Skyrme interaction.

R. Keser; A. S. Umar; V. E. Oberacker

2012-02-17T23:59:59.000Z

395

Single Atom Electron and Ion Sources and Their Applications  

E-Print Network [OSTI]

- energy electron point projection microscope, PPM) (37, 38) 1. (shadow microscopy) (shadow image-walled carbon nanotubes, SWNTs) (111) (pizeo-scanner) X- Y-Z (scanning tunneling microscope) 3. (a on the screen (mm) Intensity(Arb.Units) (c) (a) (b) Q FWHM P (a) (b)Dd sample holder detector-MCP #12;13 98

396

Generalized drift-diffusion for microscopic thermoelectricity  

E-Print Network [OSTI]

Although thermoelectric elements increasingly incorporate nano-scale features in similar material systems as other micro-electronic devices, the former are described in the language of irreversible thermodynamics while ...

Santhanam, Parthiban

2009-01-01T23:59:59.000Z

397

Coordination of Transmission Line Transfer Capabilities  

E-Print Network [OSTI]

Coordination of Transmission Line Transfer Capabilities Final Project Report Power Systems since 1996 PSERC #12;Power Systems Engineering Research Center Coordination of Transmission Line Summary The maximum power that can be transferred over any transmission line, called the transfer capacity

398

Transmission Planning | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Planning Planning Transmission Planning Modernizing America's electricity infrastructure is one of the U.S. Department of Energy's top priorities. The National Transmission Grid Study (PDF 2.0 MB) made clear that without dramatic improvements and upgrades over the next decade our nation's transmission system will fall short of the reliability standards our economy requires, and will result in higher electricity costs to consumers. The Department's research into a variety of tools that will improve advanced system monitoring, visualization, control, operations, and market structure will ultimately modernize the electricity transmission infrastructure to ease congestion, allow for increases in demand, and provide a greater degree of security. The next generation supervisory control and data acquisition (SCADA) and

399

Video transmission over wireless networks  

E-Print Network [OSTI]

Compressed video bitstream transmissions over wireless networks are addressed in this work. We first consider error control and power allocation for transmitting wireless video over CDMA networks in conjunction with multiuser detection. We map a...

Zhao, Shengjie

2005-08-29T23:59:59.000Z

400

National Electric Transmission Congestion Studies  

Broader source: Energy.gov [DOE]

Section 216(a) of the Federal Power Act, as amended by the Energy Policy Act of 2005, directs the U.S. Department of Energy (DOE) to conduct a study every three years on electric transmission congestion and constraints within the Eastern and Western Interconnections. The American Reinvestment and Recovery Act of 2009 (Recovery Act) further directed the Secretary to include in the 2009 Congestion Study an analysis of significant potential sources of renewable energy that are constrained by lack of adequate transmission capacity. Based on this study, and comments concerning it from states and other stakeholders, the Secretary of Energy may designate any geographic area experiencing electric transmission capacity constraints or congestion as a national interest electric transmission corridor (National Corridor).

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

National Transmission Grid Study: 2002  

Broader source: Energy.gov [DOE]

National Transmission Grid Study: The National Energy Policy Plan directed the U.S. Department of Energy (DOE) to conduct a study to examine the benefits of establishing a national electricity...

402

OpenEI Community - transmission  

Open Energy Info (EERE)

black out brown out bulk power system electricity grid future grid grid history security Smart Grid transmission Smart Grid Fri, 31 Oct 2014 17:58:14 +0000 Dc 955 at...

403

In situ electron microscopy study of growth of WO3 and MoO3 nanowhiskers  

Science Journals Connector (OSTI)

WO3 and MoO3 nanowhiskers were grown from nanosize WO3 and MoO3 powders intensely irradiated with electrons in an electron microscope. Solid and hollow nanowhiskers of these materials were observed. A growth mech...

1 R. T. Malkhasyan; R. K. Karakhanyan; M. N. Nazaryan…

2003-05-01T23:59:59.000Z

404

On the microscopic origin of light scattering in tissue  

Science Journals Connector (OSTI)

Understanding the nature of light scattering within tissue is a crucial issue for development of medical imaging techniques. Microscopic measurements of static light-scattering...

Kaplan, Peter; Weissman, Jesse; Hancewicz, Tom; Popp, Alois; Weitz, David

405

A Low-Cost Reflectance FT-IR Microscope  

Science Journals Connector (OSTI)

A Fourier transform infrared spectroscopy (FT-IR) microscope combines microscopy with infrared (IR) spectroscopic molecular characterization. IR microspectroscopy presents a...

Jansen, J A J; Van Der Maas, J H; Posthuma De Boer, A

1991-01-01T23:59:59.000Z

406

Microscopic Reactive Diffusion of Uranium in the Contaminated...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

States. Abstract: Microscopic and spectroscopic analysis of uranium-contaminated sediment cores beneath the BX waste tank farm at the US Department of Energy (DOE) Hanford...

407

A New Interpretation of the Scanning Tunneling Microscope Image...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of Graphite. A New Interpretation of the Scanning Tunneling Microscope Image of Graphite. Abstract: In this work, highly-resolved scanning tunneling microscopy images of graphite...

408

Development of a circularly polarizing microscope with a polarizing undulator  

Science Journals Connector (OSTI)

A circularly polarizing microscope by which we intend to obtain images with CD (circular dichroism) or CIDS (circular intensity differential scattering) in order to observe the structure and distribution of biomolecules has been constructed by using a polarizing undulator as the polarizing light source. The polarizing undulator with crossed and retarded magnetic field having fifteen periods was installed in the electron storage ring NIJI?II in the Electrotechnical Laboratory. A Schwarzschild?type mirror system combined with a convex mirror was developed in order to focus the undulator radiation to a microbeam keeping the quality of polarization of the radiation from the undulator. The beam size was from 0.66 ?m (at wavelength 200 nm) to 0.96 ?m (at 400 nm). Using a scanning sample stage and a photomultiplier which was positioned in the back of the sample some images with transmitted and scattered light from fibrous DNA have been obtained. Attempts have also been made at obtaining images with CD and CIDS from the alternation between right? and left?handed circularly polarized radiation from the undulator.

Toru Yamada; Masatada Yuri; Hideo Onuki; Shozo Ishizaka

1995-01-01T23:59:59.000Z

409

DOE Transmission Capacity Report | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Transmission Capacity Report Transmission Capacity Report DOE Transmission Capacity Report DOE Transmission Capacity Report: Transmission lines, substations, circuit breakers, capacitors, and other equipment provide more than just a highway to deliver energy and power from generating units to distribution systems. Transmission systems both complement and substitute for generation. Transmission generally enhances reliability; lowers the cost of electricity delivered to consumers; limits the ability of generators to exercise market power; and provides flexibility to protect against uncertainties about future fuel prices, load growth, generator construction, and other factors affecting the electric system. DOE Transmission Capacity Report More Documents & Publications Report to Congress:Impacts of the Federal Energy Regulatory Commission's

410

AGENDA: PETROLEUM PRODUCT TRANSMISSION & DISTRIBUTION | Department...  

Broader source: Energy.gov (indexed) [DOE]

AGENDA: PETROLEUM PRODUCT TRANSMISSION & DISTRIBUTION AGENDA: PETROLEUM PRODUCT TRANSMISSION & DISTRIBUTION A Public Meeting on the Quadrennial Energy Review, Hosted by the United...

411

Briefing Memo: Petroleum Product Transmission & Distribution...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Briefing Memo: Petroleum Product Transmission & Distribution Briefing Memo: Petroleum Product Transmission & Distribution Click below to download a PDF of the briefing memo....

412

Natural Gas Transmission and Distribution Module  

Gasoline and Diesel Fuel Update (EIA)

U.S. Energy Information Administration | Assumptions to the Annual Energy Outlook 2013 Natural Gas Transmission and Distribution Module The NEMS Natural Gas Transmission and...

413

Agenda: Natural Gas: Transmission, Storage and Distribution ...  

Broader source: Energy.gov (indexed) [DOE]

Natural Gas: Transmission, Storage and Distribution Agenda: Natural Gas: Transmission, Storage and Distribution A Public Meeting on the Quadrennial Energy Review, Hosted by the...

414

2006 National Electric Transmission Congestion Study Federal...  

Broader source: Energy.gov (indexed) [DOE]

6 National Electric Transmission Congestion Study Federal Register Notice & Comments 2006 National Electric Transmission Congestion Study Federal Register Notice & Comments The...

415

National Electric Transmission Congestion Study | Department...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Study National Electric Transmission Congestion Study National Electric Transmission Congestion Study Section 1221(a) of the Energy Policy Act of 2005, codified at 16 U.S.C....

416

2009 National Electric Transmission Congestion Study | Department...  

Broader source: Energy.gov (indexed) [DOE]

9 National Electric Transmission Congestion Study 2009 National Electric Transmission Congestion Study Section 216(a) of the Federal Power Act, as amended by the Energy Policy Act...

417

Electric Transmission Siting | Open Energy Information  

Open Energy Info (EERE)

navigation, search OpenEI Reference LibraryAdd to library Legal Document- OtherOther: Electric Transmission SitingLegal Abstract Electric Transmission Siting at the California...

418

2006 National Electric Transmission Congestion Study | Department...  

Broader source: Energy.gov (indexed) [DOE]

6 National Electric Transmission Congestion Study 2006 National Electric Transmission Congestion Study Section 216(a) of the Federal Power Act, as amended by the Energy Policy Act...

419

National Electric Transmission Congestion Study Workshops | Department...  

Broader source: Energy.gov (indexed) [DOE]

National Electric Transmission Congestion Study Workshops National Electric Transmission Congestion Study Workshops DOE hosted four regional pre-study workshops to receive input...

420

WINDExchange Offshore Wind Webinar: Transmission Planning and...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Offshore Wind Webinar: Transmission Planning and Interconnection for Offshore Wind WINDExchange Offshore Wind Webinar: Transmission Planning and Interconnection for Offshore Wind...

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Agenda: Electricity Transmission and Distribution - East | Department...  

Broader source: Energy.gov (indexed) [DOE]

Electricity Transmission and Distribution - East Agenda: Electricity Transmission and Distribution - East A Public Meeting on the Quadrennial Energy Review, Hosted by the United...

422

Agenda: Electricity Transmission, Storage and Distribution -...  

Broader source: Energy.gov (indexed) [DOE]

Electricity Transmission, Storage and Distribution - West Agenda: Electricity Transmission, Storage and Distribution - West A Public Meeting on the Quadrennial Energy Review,...

423

Southline Transmission Line | Open Energy Information  

Open Energy Info (EERE)

Impact Statement for the Southline Transmission Line Project General NEPA Document Info Energy Sector Transmission Environmental Analysis Type EIS Applicant Southline...

424

Electron Holography of Magnetic Nanostructures M.R. McCartney, R.E. Dunin-Borkowski, and D.J. Smith  

E-Print Network [OSTI]

.J. Smith Electron holography is an electron microscope imaging technique that permits quan- titative and sensitivity using electron holography. The #12;88 M.R. McCartney, R.E. Dunin-Borkowski, and D.J. Smith

Dunin-Borkowski, Rafal E.

425

Visual Positioning of Previously Defined ROIs on Microscopic Slides  

E-Print Network [OSTI]

1 Visual Positioning of Previously Defined ROIs on Microscopic Slides Grigory Begelman, Michael slide area. Various microscopy related medical applications, such as telepathology and computer aided of interest. In this paper we present a method for image-based auto positioning on a microscope slide

Rivlin, Ehud

426

Multi-transmission-line-beam interactive system  

SciTech Connect (OSTI)

We construct here a Lagrangian field formulation for a system consisting of an electron beam interacting with a slow-wave structure modeled by a possibly non-uniform multiple transmission line (MTL). In the case of a single line we recover the linear model of a traveling wave tube due to J. R. Pierce. Since a properly chosen MTL can approximate a real waveguide structure with any desired accuracy, the proposed model can be used in particular for design optimization. Furthermore, the Lagrangian formulation provides: (i) a clear identification of the mathematical source of amplification, (ii) exact expressions for the conserved energy and its flux distributions obtained from the Noether theorem. In the case of uniform MTLs we carry out an exhaustive analysis of eigenmodes and find sharp conditions on the parameters of the system to provide for amplifying regimes.

Figotin, Alexander; Reyes, Guillermo [Department of Mathematics, University of California at Irvine, Irvine, California 92697-3875 (United States)] [Department of Mathematics, University of California at Irvine, Irvine, California 92697-3875 (United States)

2013-11-15T23:59:59.000Z

427

Multi-transmission-line-beam interactive system  

E-Print Network [OSTI]

We construct here a Lagrangian field formulation for a system consisting of an electron beam interacting with a slow-wave structure modeled by a possibly non-uniform multiple transmission line (MTL). In the case of a single line we recover the linear model of a traveling wave tube (TWT) due to J.R. Pierce. Since a properly chosen MTL can approximate a real waveguide structure with any desired accuracy, the proposed model can be used in particular for design optimization. Furthermore, the Lagrangian formulation provides for: (i) a clear identification of the mathematical source of amplification, (ii) exact expressions for the conserved energy and its flux distributions obtained from the Noether theorem. In the case of uniform MTLs we carry out an exhaustive analysis of eigenmodes and find sharp conditions on the parameters of the system to provide for amplifying regimes.

Alexander Figotin; Guillermo Reyes

2013-04-19T23:59:59.000Z

428

Career Map: Power Systems/Transmission Engineer  

Broader source: Energy.gov [DOE]

The Wind Program's Career Map provides job description information for Power Systems and Transmission Engineer positions.

429

DOE Transmission System Integration Workshop  

Broader source: Energy.gov (indexed) [DOE]

Heyeck, AEP, Sr. Vice President, Transmission Heyeck, AEP, Sr. Vice President, Transmission and Chair, EPRI Power Delivery & Utilization Sector Council November 01-02, 2012 DoubleTree Hotel, Crystal City Washington D.C. DOE Transmission System Integration Workshop 2 © 2012 Electric Power Research Institute, Inc. All rights reserved. Near-Zero Emissions Long-Term Operations Renewable Integration Water Management Electric Vehicles Demand Response & Efficiency Renewable Energy Energy Storage Sensors & Control Cyber Security Supply = Demand The Power System Supply to Demand Requires a full portfolio of innovative technologies. Tomorrow's Power System One size does not fit all 3 © 2012 Electric Power Research Institute, Inc. All rights reserved. Grid Transformation to Ensure Reliability, Efficiency, Resiliency and Security

430

Transmission Lines Emulating Moving Media  

E-Print Network [OSTI]

In this paper, we show how the electromagnetic phenomena in moving magnetodielectric media can be emulated using artificial composite structures at rest. In particular, we introduce nonreciprocal periodically loaded transmission lines which support waves obeying the same rules as plane electromagnetic waves in moving media. Because the actual physical structure is at rest, in these transmission lines there are no fundamental limitations on the velocity values, which may take values larger than the speed of light or even complex values (considering complex amplitudes in the time-harmonic regime). An example circuit of a unit cell of a "moving" transmission line is presented and analyzed both numerically and experimentally. The special case of composite right/left handed host line is also studied numerically. Besides the fundamental interest, the study is relevant for potential applications in realizing engineered materials for various transformations of electromagnetic fields.

Vehmas, Joni; Tretyakov, Sergei

2014-01-01T23:59:59.000Z

431

California/Transmission | Open Energy Information  

Open Energy Info (EERE)

California/Transmission California/Transmission < California Jump to: navigation, search CaliforniaTransmissionHeader.png Roadmap Agency Links Local Regulations State Regulations Summary General Transmission Dashboard Permitting Atlas Compare States Arizona California Colorado Idaho Montana Nevada New Mexico Oregon Utah Washington Wyoming Resource Library NEPA Database The electrical grid in California is part of the WestConnect Transmission Planning area and the California Transmission Planning Group. The desert southwest region of California belongs to the Southwest Area Transmission power grid and the northern region of the state belongs to the Sierra Subregional Planning Group. The SWAT provides the technical forum required to complete reliability assessments, develop joint business opportunities and accomplish

432

In Situ Transmission Electron Microscopy Characterization of Nanomaterials  

E-Print Network [OSTI]

on the grain boundary sliding and grain rotation while the grain boundary interacting with dislocations [7-9]. The discoveries of new nanomaterials such as carbon nanotubes, nanowires and graphene have shown large potential impacts in the developments... with nanometer sized width [18]. Next, graphene nanosheet or thin film can be explained as a two dimensional nanostructured material with nanosized thickness [12, 19]. And finally, bulk nanostructed material can be exampled as a three dimensional...

Lee, Joon Hwan 1977-

2012-11-27T23:59:59.000Z

433

In Situ Transmission Electron Microscopy Observation of Microstructure...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

This prototype lithium ion battery was built using a single SnO&8322; nanowire as the anode, an air stable salt: lithium bis(trifluoromethansulfonyl) imide (LiTFSI) in a...

434

Electronic Transmission of Prescriptions Towards Realising the Dream  

E-Print Network [OSTI]

of one of these health care processes ­ the prescription processing system. The UK NHS came into being.W.Chadwick@salford.ac.uk Abstract: The United Kingdom National Health Service (NHS) is about to commence upon major computerisationD in the field of Internet Security. This has involved research (2000-2003) in the development of secure health

Kent, University of

435

The Inherent Inefficiency of Simultaneously Feasible Financial Transmission Rights Auctions  

E-Print Network [OSTI]

transmission right, electricity auction, simultaneous feasibility, transmission pricing. I. INTRODUCTION POINT

436

The Inherent Inefficiency of Simultaneously Feasible Financial Transmission Rights Auctions  

E-Print Network [OSTI]

, transmission pricing. I. INTRODUCTION POINT-TO-POINT financial transmission rights (FTRs) (see [2] and [7

437

Sample mounting and transfer for coupling an ultrahigh vacuum variable temperature beetle scanning tunneling microscope with conventional surface probes  

SciTech Connect (OSTI)

We present a new ultrahigh vacuum (UHV) chamber for surface analysis and microscopy at controlled, variable temperatures. The new instrument allows surface analysis with Auger electron spectroscopy, low energy electron diffraction, quadrupole mass spectrometer, argon ion sputtering gun, and a variable temperature scanning tunneling microscope (VT-STM). In this system, we introduce a novel procedure for transferring a sample off a conventional UHV manipulator and onto a scanning tunneling microscope in the conventional ''beetle'' geometry, without disconnecting the heating or thermocouple wires. The microscope, a modified version of the Besocke beetle microscope, is mounted on a 2.75 in. outer diameter UHV flange and is directly attached to the base of the chamber. The sample is attached to a tripod sample holder that is held by the main manipulator. Under UHV conditions the tripod sample holder can be removed from the main manipulator and placed onto the STM. The VT-STM has the capability of acquiring images between the temperature range of 180--500 K. The performance of the chamber is demonstrated here by producing an ordered array of island vacancy defects on a Pt(111) surface and obtaining STM images of these defects.

Nafisi, Kourosh; Ranau, Werner; Hemminger, John C.

2001-01-01T23:59:59.000Z

438

A soft-X-ray imaging microscope with multilayer-coated Schwarzschild optics  

Science Journals Connector (OSTI)

We constructed a soft-X-ray imaging microscope based on a multilayer-coated Schwarzschild objective. The Schwarzschild objective was designed to have a 50 x magnification and a numerical aperture of 0.25. The mirrors of the objective were coated with a Mo/Si multilayer to reflect the Si L emission. The overall throughput of the objective was 14% at a peak wavelength of 13.3 nm. The 5-?m wide stripe of SiO 2 lithographically patterned was observed under irradiation with an electron beam of 1 ?A.

M. Toyoda; Y. Shitani; M. Yanagihara; T. Ejima; M. Yamamoto; M. Watanabe

2000-01-01T23:59:59.000Z

439

Power superconducting power transmission cable  

DOE Patents [OSTI]

The present invention is for a compact superconducting power transmission cable operating at distribution level voltages. The superconducting cable is a conductor with a number of tapes assembled into a subconductor. These conductors are then mounted co-planarly in an elongated dielectric to produce a 3-phase cable. The arrangement increases the magnetic field parallel to the tapes thereby reducing ac losses.

Ashworth, Stephen P. (Cambridge, GB)

2003-01-01T23:59:59.000Z

440

Power Transmission, Distribution and Plants  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Power Transmission, Distribution and Plants A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Abdel-Aal, Radwan E. - Computer Engineering Department, King Fahd University of...

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

A near-field scanning microwave microscope based on a superconducting resonator for low power measurements  

E-Print Network [OSTI]

We report on the design and performance of a cryogenic (300 mK) near-field scanning microwave microscope. It uses a microwave resonator as the near-field sensor, operating at a frequency of 6 GHz and microwave probing amplitudes down to 100 uV, approaching low enough photon population (N~1000) of the resonator such that coherent quantum manipulation becomes feasible. The resonator is made out of a miniaturized distributed fractal superconducting circuit that is integrated with the probing tip, micromachined to be compact enough such that it can be mounted directly on a quartz tuning-fork, and used for parallel operation as an atomic force microscope (AFM). The resonator is magnetically coupled to a transmission line for readout, and to achieve enhanced sensitivity we employ a Pound-Drever-Hall measurement scheme to lock to the resonance frequency. We achieve a well localized near-field around the tip such that the microwave resolution is comparable to the AFM resolution, and a capacitive sensitivity down to 6.4x10^-20 F/rtHz, limited by mechanical noise. We believe that the results presented here are a significant step towards probing quantum systems at the nanoscale using near-field scanning microwave microscopy.

S. E. de Graaf; A. V. Danilov; A. Adamyan; S. E. Kubatkin

2014-04-02T23:59:59.000Z

442

A near-field scanning microwave microscope based on a superconducting resonator for low power measurements  

E-Print Network [OSTI]

We report on the design and performance of a cryogenic (300 mK) near-field scanning microwave microscope. It uses a microwave resonator as the near-field sensor, operating at a frequency of 6 GHz and microwave probing amplitudes down to 100 uV, approaching low enough photon population (N~1000) of the resonator such that coherent quantum manipulation becomes feasible. The resonator is made out of a miniaturized distributed fractal superconducting circuit that is integrated with the probing tip, micromachined to be compact enough such that it can be mounted directly on a quartz tuning-fork, and used for parallel operation as an atomic force microscope (AFM). The resonator is magnetically coupled to a transmission line for readout, and to achieve enhanced sensitivity we employ a Pound-Drever-Hall measurement scheme to lock to the resonance frequency. We achieve a well localized near-field around the tip such that the microwave resolution is comparable to the AFM resolution, and a capacitive sensitivity down to 6...

de Graaf, S E; Adamyan, A; Kubatkin, S E

2014-01-01T23:59:59.000Z

443

Definition: Network Integration Transmission Service | Open Energy  

Open Energy Info (EERE)

Network Integration Transmission Service Network Integration Transmission Service Jump to: navigation, search Dictionary.png Network Integration Transmission Service Service that allows an electric transmission customer to integrate, plan, economically dispatch and regulate its network reserves in a manner comparable to that in which the Transmission Owner serves Native Load customers.[1] Related Terms transmission lines, transmission customer, transmission line, native load, smart grid References ↑ Glossary of Terms Used in Reliability Standards An inli LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ne Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Network_Integration_Transmission_Service&oldid=502560" Categories: Definitions

444

Optical system for high-speed Atomic Force Microscope  

E-Print Network [OSTI]

This thesis presents the design and development of an optical cantilever deflection sensor for a high speed Atomic Force Microscope (AFM). This optical sensing system is able to track a small cantilever while the X-Y scanner ...

Lim, Kwang Yong, S.M. Massachusetts Institute of Technology

2010-01-01T23:59:59.000Z

445

Department of Mechanical Engineering "Heat Under the Microscope  

E-Print Network [OSTI]

applications ranging from thermoelectric waste heat recovery to radio astronomy. BIOGRAPHY Austin MinnichDepartment of Mechanical Engineering presents "Heat Under the Microscope: Uncovering an essential role in nearly every technological application, ranging from space power generation to consumer

Militzer, Burkhard

446

Lensless digital holographic microscope with light-emitting diode illumination  

Science Journals Connector (OSTI)

We demonstrate the operation of a digital in-line microscope with LED illumination. We show with a practical example that, for typical setups, the limited temporal coherence and the...

Repetto, L; Piano, E; Pontiggia, C

2004-01-01T23:59:59.000Z

447

Design and analysis of a monolithic flexure atomic force microscope  

E-Print Network [OSTI]

This thesis details the design, manufacture, and testing of a sub-nanometer accuracy atomic force microscope. It was made to be integrated into the Sub-Atomic Measuring Machine (SAMM) in collaboration with the University ...

Ljubicic, Dean M

2008-01-01T23:59:59.000Z

448

Development of a Schwarzschild-type x-ray microscope  

Science Journals Connector (OSTI)

A Schwarzschild-type x-ray microscope has been designed, constructed, and tested. Ni/C multilayers were used as the x-ray mirrors, with a thickness (2d) of 7 nm and 30 layer pairs. The...

Kado, M; Yamashita, K; Ohtani, M; Tanaka, K A; Kodama, R; Kitamoto, S; Yamanaka, T; Nakai, S

1991-01-01T23:59:59.000Z

449

Microscopic observations of samples affected by delayed ettringite formation (DEF)  

Science Journals Connector (OSTI)

This article, which deals with the study of the microscopic modifications of DEF-affected materials, has two main objectives. The first one is to study the influence of sample preparation on the microcracks of sp...

Nordine Leklou; Jean-Emmanuel Aubert; Gilles Escadeillas

2009-12-01T23:59:59.000Z

450

Construction of an ultra-low temperature scanning tunneling microscope  

Science Journals Connector (OSTI)

We describe designs and specifications of an ultra-low temperature scanning tunneling microscope developed at ... works over a wide temperature range between 90 mK and 300 K with atomic resolution as...

Hiroshi Fukuyama; Hiroki Tan; Tetsuya Handa…

1996-01-01T23:59:59.000Z

451

Imaging of quantum Hall edge states under quasiresonant excitation by a near-field scanning optical microscope  

SciTech Connect (OSTI)

A high resolution mapping of quantum Hall edge states has been performed by locally creating electrons with small excess energies with a near-field scanning optical microscope in a dilution refrigerator. We have observed fine structures parallel to the edge in photovoltage signals, which appear only at low temperature. The observed fine structures near sample edges have been seen to shift inward with increase in magnetic field in accordance with Chklovskii Shklovskii, and Glazman model.

Ito, H.; Shibata, Y.; Mamyoda, S.; Ootuka, Y.; Nomura, S. [Division of Physics, University of Tsukuba, Tennodai, Tsukuba, 305-8571 (Japan); Kashiwaya, S. [National Institute of Advanced Industrial Science and Technology (AIST), Umezono, Tsukuba, 305-8568 (Japan); Yamaguchi, M.; Akazaki, T.; Tamura, H. [NTT Basic Research Laboratories, NTT Corporation, Morinosato-Wakamiya, Atsugi, 243-0198 (Japan)

2013-12-04T23:59:59.000Z

452

A CCD Camera with Electron Decelerator for Intermediate Voltage Electron Microscopy  

SciTech Connect (OSTI)

Electron microscopists are increasingly turning to Intermediate Voltage Electron Microscopes (IVEMs) operating at 300 - 400 kV for a wide range of studies. They are also increasingly taking advantage of slow-scan charge coupled device (CCD) cameras, which have become widely used on electron microscopes. Under some conditions CCDs provide an improvement in data quality over photographic film, as well as the many advantages of direct digital readout. However, CCD performance is seriously degraded on IVEMs compared to the more conventional 100 kV microscopes. In order to increase the efficiency and quality of data recording on IVEMs, we have developed a CCD camera system in which the electrons are decelerated to below 100 kV before impacting the camera, resulting in greatly improved performance in both signal quality and resolution compared to other CCDs used in electron microscopy. These improvements will allow high-quality image and diffraction data to be collected directly with the CCD, enabling improvements in data collection for applications including high-resolution electron crystallography, single-particle reconstruction of protein structures, tomographic studies of cell ultrastructure and remote microscope operation. This approach will enable us to use even larger format CCD chips that are being developed with smaller pixels.

Downing, Kenneth H; Downing, Kenneth H.; Mooney, Paul E.

2008-03-17T23:59:59.000Z

453

NREL: Transmission Grid Integration - Webinars  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Webinars Webinars Want updates about future transmission grid integration webinars and publications? Join our mailing list. NREL periodically offers webinars on transmission grid integration topics to provide insight into its research. Explore the resources below to learn more. Upcoming Webinars Please check back. Details on future meetings and workshops will be posted as they are available. Past Webinars Results from The Western Wind and Solar Integration Study Phase 2: An examination of how wind and solar power affect operations, costs, and emissions from fossil-fueled generators Wednesday, September 25, 2013 at 12:00 EDT (10:00 MDT) The Western Wind and Solar Integration Study Phase 2 (WWSIS-2), launched in 2011, examines the potential impacts of up to 33% wind and solar energy

454

DOE Electricity Transmission System Workshop  

Broader source: Energy.gov (indexed) [DOE]

TRANSMISSION SYSTEM WORKSHOP TRANSMISSION SYSTEM WORKSHOP Mapping Challenges and Opportunities to Help Guide DOE R&D Investments over the Next Five Years DoubleTree Crystal City, 300 Army Navy Drive, Arlington, VA November 1-2, 2012 AGENDA Thursday, November 1, 2012 8:00-8:10 Welcome and Kickoff David Sandalow, Acting Undersecretary of Energy 8:10-8:30 Introduction to the Grid Tech Team (GTT), Vision, and Framework Distribution Workshop Summary Dr. Anjan Bose, Grid Tech Team Lead 8:30-8:50 OE Vision, Activities, and Issues Patricia A. Hoffman, Assistant Secretary for the Office of Electricity Delivery and Energy Reliability (OE) 8:50-9:10 EERE Vision, Activities, and Issues Dr. David Danielson, Assistant Secretary for the Office of Energy Efficiency and Renewable Energy (EERE)

455

transmission | OpenEI Community  

Open Energy Info (EERE)

21 21 Varnish cache server Home Groups Community Central Green Button Applications Developer Utility Rate FRED: FRee Energy Database More Public Groups Private Groups Features Groups Blog posts Content Stream Documents Discussions Polls Q & A Events Notices My stuff Energy blogs 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142235321 Varnish cache server transmission Home Kyoung's picture Submitted by Kyoung(155) Contributor 12 November, 2012 - 09:17 Legal Reviews are Underway BHFS Legal review permitting power plant roadmap transmission The legal review of the Regulatory Roadmap flowcharts and supporting content is well underway and will continue for the next several months with our legal team at [www.bhfs.com Brownstein Hyatt Farber and Schreck]. The

456

Electronics Engineer  

Broader source: Energy.gov [DOE]

This position is located in Transmission Communications Test and Engergization (TETD) of the Bonneville Power Administration (BPA). Communications Test and Energization (T&E;) provides start-up...

457

Absence of Patient-to-Patient Intrahospital Transmission of Staphylococcus aureus as Determined by Whole-Genome Sequencing  

Science Journals Connector (OSTI)

...infections. The lack of intrahospital transmission may reflect a fundamental difference between day-to-day transmission events in...no further review was performed on that pair. Next, the electronic medical records of both patients in the isolate pair were...

S. Wesley Long; Stephen B. Beres; Randall J. Olsen; James M. Musser

2014-10-01T23:59:59.000Z

458

Recovery Act Interconnection Transmission Planning  

Broader source: Energy.gov [DOE]

Robust and reliable transmission and distribution networks are essential to achieving the Administration's clean energy goals, including the development, integration, and delivery of new renewable and other low-carbon resources in the electricity sector, and the use of these resources to displace petroleum-based fuels in the transportation sector. OE is helping to strengthen the capabilities for long-term analysis and planning in the three interconnections serving the lower 48 United States.

459

Coiled transmission line pulse generators  

DOE Patents [OSTI]

Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

McDonald, Kenneth Fox (Columbia, MO)

2010-11-09T23:59:59.000Z

460

MODIFYING AN INVERTED LABORATORY MICROSCOPE FOR RAMAN Presented in Partial Fulfillment of the Requirements for  

E-Print Network [OSTI]

MODIFYING AN INVERTED LABORATORY MICROSCOPE FOR RAMAN MICROSCOPY A Thesis Presented in Partial modifications a spectroscopic imaging instrument, a Raman microscope, can be constructed from a common inverted

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Definition: Transmission Service | Open Energy Information  

Open Energy Info (EERE)

Service Service Jump to: navigation, search Dictionary.png Transmission Service Services provided to the Transmission Customer by the Transmission Service Provider to move energy from a Point of Receipt to a Point of Delivery.[1] Related Terms transmission lines, Transmission Customer, Transmission Service Provider, transmission line References ↑ Glossary of Terms Used in Reliability Standards An inl LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ine Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Transmission_Service&oldid=480302" Categories: Definitions ISGAN Definitions What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load)

462

Arizona/Transmission/Summary | Open Energy Information  

Open Energy Info (EERE)

Arizona‎ | Transmission Arizona‎ | Transmission Jump to: navigation, search ArizonaTransmissionHeader.png Roadmap Agency Links Local Regulations State Regulations Summary General Transmission Dashboard Permitting Atlas Compare States Arizona California Colorado Idaho Montana Nevada New Mexico Oregon Utah Washington Wyoming Resource Library NEPA Database Transmission Permitting at a Glance In Arizona, the state has the authority to site high-voltage transmission lines. A public service corporation would need to obtain a Certificate of Environmental Compatibility (CEC) from the Arizona Power Plant and Transmission Line Siting Committee that is "affirmed and approved" by the Arizona Corporation Commission (ACC). State Siting Act Arizona Revised Statute (A.R.S.)§ 40-360 et seq. State Preemptive Authority If the Transmission Line Siting Committee (TLSC) finds that compliance with local ordinances, master plan or regulation is unreasonably restrictive and compliance is not feasible in view of technology available, then the TLSC may grant a certificate.[1]

463

Georgia Transmission Corp | Open Energy Information  

Open Energy Info (EERE)

for 2010 - File1a1 EIA Form 861 Data Utility Id 7197 Utility Location Yes Ownership T NERC Location SERC NERC SERC Yes Activity Transmission Yes Activity Buying Transmission...

464

Ebola virus transmission in guinea pigs  

Science Journals Connector (OSTI)

...Rights Reserved. 2014 research-article Ebola virus transmission in guinea pigs Gary...School of Medicine, Philadelphia, PA, USA Ebola virus (EBOV) transmission is currently...movement over short distances. Importance Ebola is generally thought to be spread between...

Gary Wong; Xiangguo Qiu; Jason S. Richardson; Todd Cutts; Brad Collignon; Jason Gren; Jenna Aviles; Carissa Embury-Hyatt; Gary P. Kobinger

2014-11-12T23:59:59.000Z

465

MagLab - Transmission Lines Tutorial  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Tweet Education Home > MagLab U > Interactive Tutorials Arrow Transmission Lines More than half a million miles of high-voltage transmission lines criss-cross the United States. If...

466

Transmission Issues and Power Exchanges in Texas  

E-Print Network [OSTI]

on the transmission owning utilities by several parties, primary distribution cooperatives, cogenerators, and large industrial customers, to grant wider access to the system. This pressure is coming at a time when transmission lines are becoming increasingly difficult...

Hughes, H. L.

467

Vibration Transmission through Symmetric Resonant Couplings  

Science Journals Connector (OSTI)

15 March 1994 research-article Vibration Transmission through Symmetric Resonant Couplings D. J. Allwright...Blakemore P. R. Brazier-Smith J. Woodhouse The transmission of vibration through a symmetric junction is considered. The problem is...

1994-01-01T23:59:59.000Z

468

Estes-Flatiron Transmission Line Rebuild  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Estes-Flatiron Transmission Line Rebuild Estes-Flatiron Transmission Line Rebuild Skip Navigation Links Transmission Functions Infrastructure projects Interconnection OASIS OATT Estes-Flatiron Transmission Line Rebuild Project Western Area Power Administration proposes to rebuild approximately 32 miles of double wood-pole structure 115-kilovolt transmission line that exists between Estes Park and Flatiron Reservoir in Larimer County, Colo. The proposal would remove 16 miles of transmission line, and modernize 16 miles to steel-pole double-circuit 115-kV transmission line. The reduction and modernizing of transmission lines will occur on Federal, state and private lands. The public parcels are administered by the Arapaho and Roosevelt National Forest, which is a cooperating agency in the project.

469

EEI/DOE Transmission Capacity Report  

Broader source: Energy.gov (indexed) [DOE]

TRANSMISSION CAPACITY: TRANSMISSION CAPACITY: PRESENT STATUS AND FUTURE PROSPECTS Eric Hirst Consulting in Electric-Industry Restructuring Bellingham, Washington June 2004 Prepared for Energy Delivery Group Edison Electric Institute Washington, DC Russell Tucker, Project Manager and Office of Electric Transmission and Distribution U.S. Department of Energy Washington, DC Larry Mansueti, Project Manager ii iii CONTENTS Page SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v LIST OF ACRONYMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii 1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. TRANSMISSION CAPACITY: DATA AND PROJECTIONS . . . . . . . . . . . . . . . . . . . 5 HISTORICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 CURRENT CONDITIONS . . . . . . .

470

Mountain States Transmission Intertie (MSTI) Project  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Improvement (CBPI) Customer Forum Energy Imbalance Market Generator Interconnection Reform Implementation Network Integration Transmission Service (NT Service) Network Open...

471

Sandia National Laboratories: Transmission Grid Integration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Infrastructure Security, Modeling, Modeling & Analysis, News, News & Events, Renewable Energy, SMART Grid, Systems Analysis, Transmission Grid Integration, Wind Energy Sandia...

472

Integrated Transmission and Distribution Control  

SciTech Connect (OSTI)

Distributed, generation, demand response, distributed storage, smart appliances, electric vehicles and renewable energy resources are expected to play a key part in the transformation of the American power system. Control, coordination and compensation of these smart grid assets are inherently interlinked. Advanced control strategies to warrant large-scale penetration of distributed smart grid assets do not currently exist. While many of the smart grid technologies proposed involve assets being deployed at the distribution level, most of the significant benefits accrue at the transmission level. The development of advanced smart grid simulation tools, such as GridLAB-D, has led to a dramatic improvement in the models of smart grid assets available for design and evaluation of smart grid technology. However, one of the main challenges to quantifying the benefits of smart grid assets at the transmission level is the lack of tools and framework for integrating transmission and distribution technologies into a single simulation environment. Furthermore, given the size and complexity of the distribution system, it is crucial to be able to represent the behavior of distributed smart grid assets using reduced-order controllable models and to analyze their impacts on the bulk power system in terms of stability and reliability. The objectives of the project were to: • Develop a simulation environment for integrating transmission and distribution control, • Construct reduced-order controllable models for smart grid assets at the distribution level, • Design and validate closed-loop control strategies for distributed smart grid assets, and • Demonstrate impact of integrating thousands of smart grid assets under closed-loop control demand response strategies on the transmission system. More specifically, GridLAB-D, a distribution system tool, and PowerWorld, a transmission planning tool, are integrated into a single simulation environment. The integrated environment allows the load flow interactions between the bulk power system and end-use loads to be explicitly modeled. Power system interactions are modeled down to time intervals as short as 1-second. Another practical issue is that the size and complexity of typical distribution systems makes direct integration with transmission models computationally intractable. Hence, the focus of the next main task is to develop reduced-order controllable models for some of the smart grid assets. In particular, HVAC units, which are a type of Thermostatically Controlled Loads (TCLs), are considered. The reduced-order modeling approach can be extended to other smart grid assets, like water heaters, PVs and PHEVs. Closed-loop control strategies are designed for a population of HVAC units under realistic conditions. The proposed load controller is fully responsive and achieves the control objective without sacrificing the end-use performance. Finally, using the T&D simulation platform, the benefits to the bulk power system are demonstrated by controlling smart grid assets under different demand response closed-loop control strategies.

Kalsi, Karanjit; Fuller, Jason C.; Tuffner, Francis K.; Lian, Jianming; Zhang, Wei; Marinovici, Laurentiu D.; Fisher, Andrew R.; Chassin, Forrest S.; Hauer, Matthew L.

2013-01-16T23:59:59.000Z

473

BPA, Electric Transmission Overview, October 2012  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Electric Transmission Overview Electric transmission Electric transmission is the process by which large amounts of...

474

The real problem with Merchant transmission  

SciTech Connect (OSTI)

Current regulatory policy distinguishes transmission investments that have primarily economic benefits from those that primarily enhance reliability. But no such dichotomy exists; congestion and reliability are inter-related in complex ways. Thus, solving the transmission investment problem is more complex than ''fixing'' merchant transmission; investment in the grid must be treated as a systems problem. (author)

Blumsack, Seth; Lave, Lester B.; Ilic, Marija

2008-03-15T23:59:59.000Z

475

Spectral Theory for Nonconservative Transmission Line Networks  

E-Print Network [OSTI]

Spectral Theory for Nonconservative Transmission Line Networks Robert Carlson Department The global theory of transmission line networks with nonconserva- tive junction conditions is developed from is determined. Specialized results are developed for rational graphs. 1 #12;1 Introduction The transmission line

Carlson, Bob

476

Foil Electron Multiplier  

DOE Patents [OSTI]

An apparatus for electron multiplication by transmission that is designed with at least one foil having a front side for receiving incident particles and a back side for transmitting secondary electrons that are produced from the incident particles transiting through the foil. The foil thickness enables the incident particles to travel through the foil and continue on to an anode or to a next foil in series with the first foil. The foil, or foils, and anode are contained within a supporting structure that is attached within an evacuated enclosure. An electrical power supply is connected to the foil, or foils, and the anode to provide an electrical field gradient effective to accelerate negatively charged incident particles and the generated secondary electrons through the foil, or foils, to the anode for collection.

Funsten, Herbert O. (Los Alamos, NM); Baldonado, Juan R. (Los Alamos, NM); Dors, Eric E. (Los Alamos, NM); Harper, Ronnie W. (Los Alamos, NM); Skoug, Ruth M. (Los Alamos, NM)

2006-03-28T23:59:59.000Z

477

Fact #802: November 4, 2013 Market Share by Transmission Type...  

Energy Savers [EERE]

2: November 4, 2013 Market Share by Transmission Type Fact 802: November 4, 2013 Market Share by Transmission Type The variety of transmission technologies has increased as...

478

Western-UGP Transmission and Ancillary Services Rates Customer...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

80 Percentage of transmission plant included in UMZ Rates (line 79 line 76) TP 1.00000 TRANSMISSION EXPENSES 81 Total transmission expenses (sum lines 41 to 43,...

479

RAPID/BulkTransmission/About | Open Energy Information  

Open Energy Info (EERE)

Contribute Contact Us About Bulk Transmission Lattice.jpg High-voltage transmission lines form the backbone of electricity systems. Transmission lines are designed to carry...

480

RAPID/Geothermal/Transmission Siting & Interconnection/Nevada...  

Open Energy Info (EERE)

Siting Agency: Public Utilities Commission of Nevada Transmission Siting Transmission lines over 200 kV are handled by the state's CPCN process. Siting of transmission lines with...

Note: This page contains sample records for the topic "transmission electron microscope" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Electronic, optical, and mechanical characterization of zero- and one- dimensional nanostructures  

E-Print Network [OSTI]

o f carbon nanotubes by transmission electron energy-losssemiconducting nanotubes, with small energy band gap. (10.5)semiconducting nanotubes have an energy bandgap predicted to

Ni, Chi-Nung

2008-01-01T23:59:59.000Z

482

Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics  

E-Print Network [OSTI]

Transmission Ion Chamber (TIC) Secondary Electron Monitor (Faraday cup (MLFC) Segmented TIC Gafchromic film (GF) TABLEBeam Characterization Tools TIC (dose, uniformity), GF (

McMahan, Margaret A.

2008-01-01T23:59:59.000Z

483

Colorado/Transmission/Roadmap | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Colorado/Transmission/Roadmap < Colorado‎ | Transmission Jump to: navigation, search ColoradoTransmissionHeader.png Roadmap Agency Links Local Regulations State Regulations Summary General Transmission Dashboard Permitting Atlas Compare States Arizona California Colorado Idaho Montana Nevada New Mexico Oregon Utah Washington Wyoming Resource Library NEPA Database The flowcharts listed below cover the major requirements for developing transmission - both interconnects and major, multi-jurisdictional lines - including, land access, siting, and relevant environmental considerations.

484

SunZia Southwest Transmission Project Comments  

Broader source: Energy.gov (indexed) [DOE]

SunZia Southwest Transmission Project SunZia Southwest Transmission Project Comments Provided to the US Department of Energy Office of Electricity Delivery and Energy Reliability Request for Information Relating to the Permitting of Transmission Lines Submitted as of March 28, 2012 2 1.0 Background. SunZia Southwest Transmission Project (SunZia or the Project) is a joint development effort currently underway in Arizona and New Mexico. The Project definition includes licensing, permitting, financing, constructing and operating up to two 500 kilovolt alternating current (AC) transmission lines and up to five interconnecting substations.

485

California/Transmission/Roadmap | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » California/Transmission/Roadmap < California‎ | Transmission Jump to: navigation, search CaliforniaTransmissionHeader.png Roadmap Agency Links Local Regulations State Regulations Summary General Transmission Dashboard Permitting Atlas Compare States Arizona California Colorado Idaho Montana Nevada New Mexico Oregon Utah Washington Wyoming Resource Library NEPA Database The flowcharts listed below cover the major requirements for developing transmission - both interconnects and major, multi-jurisdictional lines - including, land access, siting, and relevant environmental considerations.

486

Arizona/Transmission/Roadmap | Open Energy Information  

Open Energy Info (EERE)

Roadmap Roadmap < Arizona‎ | Transmission Jump to: navigation, search ArizonaTransmissionHeader.png Roadmap Agency Links Local Regulations State Regulations Summary General Transmission Dashboard Permitting Atlas Compare States Arizona California Colorado Idaho Montana Nevada New Mexico Oregon Utah Washington Wyoming Resource Library NEPA Database The flowcharts listed below cover the major requirements for developing transmission - both interconnects and major, multi-jurisdictional lines - including, land access, siting, and relevant environmental considerations. Reading the Roadmap The flowcharts are divided into General, Federal, and State columns to allow for ease of use. To use the flowcharts, start with General Flowchart for Section 8: Transmission. The General Flowchart will lead you to the

487

Relativistic tunneling and accelerated transmission  

E-Print Network [OSTI]

We obtain the solutions for the tunneling zone of a one-dimensional electrostatic potential in the relativistic (Dirac to Klein-Gordon) wave equation regime when the incoming wave packet exhibits the possibility of being almost totally transmitted through the potential barrier. The conditions for the occurrence of accelerated and, eventually, superluminal tunneling transmission probabilities are all quantified and the problematic superluminal interpretation originated from the study based on non-relativistic dynamics of tunneling is overcome. The treatment of the problem suggests revealing insights into condensed-matter experiments using electrostatic barriers in single- and bi-layer graphene, for which the accelerated tunneling effect deserves a more careful investigation.

Alex E. Bernardini

2007-06-26T23:59:59.000Z

488

FPL's Christmas 1991 transmission outages  

SciTech Connect (OSTI)

A record number of contamination related outages occurred on FPL transmission lines during Christmas of 1991 and resulted in an investigation of inservice insulator performance. The field investigation process used was enhanced by recent improvements in outage data recording. Also used in the analysis were weather information, the results of recently completed accelerated aging tests of polymers, and specially conducted tests on the effects of weathering steel stain on porcelain insulators. Specific insulator problems were identified and actions taken to reduce the possibility of recurrence.

Burnham, J.T.; Busch, D.W.; Renowden, J.D. (Florida Power Light Co., Juno Beach, FL (United States). Transmission Line Dept.)

1993-10-01T23:59:59.000Z

489

Pulse shaping with transmission lines  

DOE Patents [OSTI]

A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

Wilcox, Russell B. (Oakland, CA)

1987-01-01T23:59:59.000Z

490

Vibration-Assisted Electron Tunneling in C140 Transistors  

Science Journals Connector (OSTI)

Vibration-Assisted Electron Tunneling in C140 Transistors ... When electrons travel through molecules, vibrational modes of the molecules can affect current flow. ... 1 Recently, effects of vibrations in single molecules have been measured using scanning tunneling microscopes,2 single-molecule transistors,3,4 and mechanical break junctions. ...

A. N. Pasupathy; J. Park; C. Chang; A. V. Soldatov; S. Lebedkin; R. C. Bialczak; J. E. Grose; L. A. K. Donev; J. P. Sethna; D. C. Ralph; P. L. McEuen

2005-01-07T23:59:59.000Z

491

Idaho/Transmission/Roadmap | Open Energy Information  

Open Energy Info (EERE)

Idaho/Transmission/Roadmap Idaho/Transmission/Roadmap < Idaho‎ | Transmission Jump to: navigation, search IdahoTransmissionHeader.png Roadmap Agency Links Local Regulations State Regulations Summary General Transmission Dashboard Permitting Atlas Compare States Arizona California Colorado Idaho Montana Nevada New Mexico Oregon Utah Washington Wyoming Resource Library NEPA Database The flowcharts listed below cover the major requirements for developing transmission - both interconnects and major, multi-jurisdictional lines - including, land access, siting, and relevant environmental considerations. Reading the Roadmap The flowcharts are divided into General, Federal, and State columns to allow for ease of use. To use the flowcharts, start with General Flowchart for Section 8: Transmission. The General Flowchart will lead you to the

492

Idaho/Transmission/Summary | Open Energy Information  

Open Energy Info (EERE)

Idaho‎ | Transmission Idaho‎ | Transmission Jump to: navigation, search IdahoTransmissionHeader.png Roadmap Agency Links Local Regulations State Regulations Summary General Transmission Dashboard Permitting Atlas Compare States Arizona California Colorado Idaho Montana Nevada New Mexico Oregon Utah Washington Wyoming Resource Library NEPA Database Transmission Permitting at a Glance In Idaho, the state's siting authority is limited to siting approvals on state property, and high voltage transmission lines (115kV or greater) within a National Interstate Electric Transmission Corridor (NIETC). Under these circumstances a Route Permit would be required by the Idaho Public Utilities Commission (IPUC); however, no such corridors have been designated and therefore the process has not been tested. Local governments

493

Colorado/Transmission/Summary | Open Energy Information  

Open Energy Info (EERE)

Colorado/Transmission/Summary Colorado/Transmission/Summary < Colorado‎ | Transmission Jump to: navigation, search ColoradoTransmissionHeader.png Roadmap Agency Links Local Regulations State Regulations Summary General Transmission Dashboard Permitting Atlas Compare States Arizona California Colorado Idaho Montana Nevada New Mexico Oregon Utah Washington Wyoming Resource Library NEPA Database Transmission Permitting at a Glance In Colorado, local governments (counties and municipalities) have the authority to site high-voltage transmission lines. The State's authority in siting is limited to a backstop appeal process, by which utilities may submit an appeal to local government decisions to the Colorado Public Utilities Commission (CPUC) for review and resolution. State Siting Act None State Preemptive Authority The CPUC has backstop authority only. If a permit is denied by the local government, the applicant may appeal to the CPUC if certain conditions are met (CRS 29-20-108).

494

Open Access Transmission and Renewable Energy Technologies  

SciTech Connect (OSTI)

In April 1996, the Federal Regulatory Commission (PERC) approved Orders 888 and 889 and released a draft rule for public comment on capacity reservation tariffs (CRTs). Order No. 888 requires electric utilities to file transmission tariffs that would allow transmission access to third parties who want to conduct wholesale transactions, and Order No. 889 requires transmission-owning utilities to set up open access, same-time information systems (OASIS), using commercial software and Internet protocols. This paper discusses these Orders in detail, as well as some of the issues before FERC with implications for renewables, which include: transmission pricing; transmission terms and conditions; reassignment of transmission capacity; defining state and FERC jurisdiction over transmission and distribution; the pricing of ancillary services; and the adoption and implementation of independent system operators.

Porter, K.

1996-09-01T23:59:59.000Z

495

The Cost of Transmission for Wind Energy in the United States: A Review of Transmission Planning Studies.  

E-Print Network [OSTI]

large, but conceptual, transmission lines such as the C/PNW-very conceptual transmission lines that resemble radialand voltage of transmission lines added in the study, as

Wiser, Ryan

2014-01-01T23:59:59.000Z

496

A new scanning photoemission microscope for ELETTRA: SuperMAXIMUM  

Science Journals Connector (OSTI)

High brightness third?generation synchrotrons allow diffraction?limited performance and large flux for scanning photoemission microscopes. A new microscope SuperMAXIMUM is being developed at the University of Wisconsin Center for X ray Lithography in collaboration with the Sincrotrone Trieste. The beamline being built in Trieste uses a variable angle spherical gratingmonochromator (VASGM). A combination of rotation of a plane mirror and rotation of the spherical grating keeps the slit positions and beam directions fixed. The microscope objectives are normal?incidence multilayer?coated Schwarzschild objectives. The project which is nearing completion utilizes novel designs for optics alignment sample rastering mechanics and software control. We will discuss the project status new designs and techniques.

John T. Welnak; H. Solak; J. Wallace; F. Cerrina; F. Barbo; M. Bertolo; A. Bianco; S. Di Fonzo; S. Fontana; W. Jark; F. Mazzolini; R. Rosei; A. Savoia; J.H. Underwood; G. Margaritondo

1996-01-01T23:59:59.000Z

497

A new scanning photoemission microscope for ELETTRA: SuperMAXIMUM  

SciTech Connect (OSTI)

High brightness, third-generation synchrotrons allow diffraction-limited performance and large flux for scanning photoemission microscopes. A new microscope, SuperMAXIMUM, is being developed at the University of Wisconsin Center for X ray Lithography in collaboration with the Sincrotrone Trieste. The beamline, being built in Trieste, uses a variable angle spherical grating monochromator (VASGM). A combination of rotation of a plane mirror and rotation of the spherical grating keeps the slit positions and beam directions fixed. The microscope objectives are normal-incidence, multilayer-coated Schwarzschild objectives. The project, which is nearing completion, utilizes novel designs for optics alignment, sample rastering mechanics, and software control. We will discuss the project status, new designs, and techniques. {copyright} {ital 1996 American Institute of Physics.}

Welnak, J.T.; Solak, H.; Wallace, J.; Cerrina, F.; Barbo, F.; Bertolo, M.; Bianco, A.; Di Fonzo, S.; Fontana, S.; Jark, W.; Mazzolini, F.; Rosei, R.; Savoia, A.; Underwood, J.; Margaritondo, G. [University of WI--Center for X ray Lithography, 3731 Schneider Drive, Stoughton, WI 53589 (United States)] [University of WI--Center for X ray Lithography, 3731 Schneider Drive, Stoughton, WI 53589 (United States); [Sincrotrone Trieste, Padriciano 99, 34012, Trieste (Italy); [Lawrence Berkeley Laboratory, Center for X ray Optics, 1 Cyclotron Road, 80-101, Berkeley, CA 94720 (United States); [Institut de Physique Appliqee, Ecole Polytechnique Federale, CH-1015, Lausanne (Switzerland)

1996-09-01T23:59:59.000Z

498

Near-Field Analysis of Bright and Dark Modes on Plasmonic Metasurfaces Showing Extraordinary Suppressed Transmission  

E-Print Network [OSTI]

Plasmonic metasurfaces are investigated that consist of a sub wavelength line pattern in an ultrathin (~ 10 nm) silver film, designed for extraordinarily suppressed transmission (EOST) in the visible spectral range. Measurements with a near-field scanning optical microscope (NSOM) demonstrate that far field irradiation creates resonant excitations of antenna like (bright) modes that are localized on the metal ridges. In contrast, bound (dark) surface plasmon polaritons (SPPs) launched from an NSOM tip propagate well across the metasurface, preferentially perpendicular to the grating lines.

Dobmann, Sabine; Ploss, Daniel; Peschel, Ulf

2014-01-01T23:59:59.000Z

499

The Cost of Transmission for Wind Energy in the United States: A Review of Transmission Planning Studies.  

E-Print Network [OSTI]

wind with transmission alternative 7b (500 kV AC line fromkV line CAISO - A4 Central California Clean Energy TransmissionTransmission Line: Transmission Development Facilities Application Volume One MATL New 230 kV

Wiser, Ryan

2014-01-01T23:59:59.000Z

500

Superconducting transmission line particle detector  

DOE Patents [OSTI]

A microvertex particle detector for use in a high energy physic collider including a plurality of parallel superconducting thin film strips separated from a superconducting ground plane by an insulating layer to form a plurality of superconducting waveguides. The microvertex particle detector indicates passage of a charged subatomic particle by measuring a voltage pulse measured across a superconducting waveguide caused by the transition of the superconducting thin film strip from a superconducting to a non- superconducting state in response to the passage of a charged particle. A plurality of superconducting thin film strips in two orthogonal planes plus the slow electromagnetic wave propagating in a superconducting transmission line are used to resolve N/sup 2/ ambiguity of charged particle events. 6 figs.

Gray, K.E.

1988-07-28T23:59:59.000Z