New energy efficient torchieres ready for hot torchiere market  

Science Conference Proceedings (OSTI)

The extraordinary market growth of the high power halogen torchiere (halogen uplighter) presents significant global energy savings opportunities for energy efficient alternatives. Extensive developed of prototype designs of energy efficient torchiere systems using compact fluorescent lamps (CFLs) has lead directly to the production and commercialization of CFL torchieres. This paper analyzes the current global market for torchieres and compares the electrical and photometric characteristics of one of the new CFL torchieres to standard tungsten halogen torchieres. Power assessments and photometric data indicate that the new CFL torchiere provides significant energy savings over the standard tungsten halogen torchiere while producing more luminous flux. The energy savings is jointly due to the high source efficacy of the CFLs and the poor performance of many cheaply made halogen lamps. Laboratory and in-situ experiments indicate that the CFL torchieres use 65 Watts to produce 25% more light than the 300 W tungsten halogen torchieres they are designed to replace. Additionally, the CFL torchieres have the benefit of a cooler lamp operating temperature, making them safer luminaires (Brooks, 1997; New York Times, 1997). This safety benefit, coupled with the potential for significant reductions in global greenhouse gas emissions, has prompted the insurance industry to form a unique alliance with energy conservation groups to promote energy efficient torchieres.

Page, E.; Mills, E.; Siminovitch, M.

1997-11-01T23:59:59.000Z

2

Photometric assessment of energy efficient torchieres  

SciTech Connect

Extensive development of designs and prototyping of energy efficient torchiere systems using compact fluorescent lamps (CFLs) has led directly to the production of CFL torchieres by a major US manufacturer. This paper compares the electrical and photometric characteristics of one of the new CFL torchieres to standard tungsten halogen torchieres (halogen uplighters). Power assessments and gonio-photometric data indicate that the new CFL torchiere provides significant energy savings over the standard tungsten halogen torchiere while producing more luminous flux. The energy savings is jointly due to the high source efficacy of the CFLs and the poor performance . of the imported halogen lamps. The paper also presents results from a test site in the student dormitories at Stanford University where a torchiere "lamp swap" program was initiated in which students voluntarily traded their halogen torchieres for CFL torchieres. Out of the 500 torchieres involved in the lamp swap, a random sample of nearly 100 halogen lamps (seasoned in the field and considered to represent a typical population) were collected and photometrically and electrically characterized in the laboratory. These laboratory results indicate that the CFL torchieres use 65 watts to produce 25 percent more light than the 300 W tungsten halogen torchieres they are designed to replace. Additionally, the CFL torchieres have the benefit of a cooler lamp operating temperature, making them safer luminaires.

Page, Erik; Siminovitch, Michael

1997-06-01T23:59:59.000Z

3

Contract No. DE-AC03-76SF00098. New Energy Efficient Torchieres Ready For Hot Torchiere Market ABSTRACT  

E-Print Network (OSTI)

The extraordinary market growth of the high power halogen torchiere (halogen uplighter) presents significant global energy savings opportunities for energy efficient alternatives. Extensive development of prototype designs of energy efficient torchiere systems using compact fluorescent lamps (CFLs) has lead directly to the production and commercialization of CFL torchieres. This paper analyzes the current global market for torchieres and compares the electrical and photometric characteristics of one of the new CFL torchieres to standard tungsten halogen torchieres. Power assessments and photometric data indicate that the new CFL torchiere provides significant energy savings over the standard tungsten halogen torchiere while producing more luminous flux. The energy savings is jointly due to the high source efficacy of the CFLs and the poor performance of many cheaply made halogen lamps. Laboratory and in-situ experiments indicate that the CFL torchieres use 65 Watts to produce 25 percent more light than the 300 W tungsten halogen torchieres they are designed to replace. Additionally, the CFL torchieres have the benefit of a cooler lamp operating temperature, making them safer luminaires (Brooks, 1997; New York Times, 1997). This safety benefit, coupled with the potential for significant reductions in global greenhouse gas emissions, has prompted the insurance industry to form a unique alliance with energy conservation groups to promote energy efficient torchieres.

Evan Mills; Michael Siminovitch; Evan Mills; Michael Siminovitch

1998-01-01T23:59:59.000Z

4

Energy-Efficient Torchieres for Residential Applications  

NLE Websites -- All DOE Office Websites (Extended Search)

up a consortium between large lamp, ballast and fixture companies to produce a dedicated CFL torchiere which uses only 55 Watts of power, but produces more light than its 300 Watt...

5

Photometric assessment of energy efficient torchieres  

E-Print Network (OSTI)

performance of a high-efficiency CFL torchiere in comparisonCFL - Half Halogen - Full Halogen - Half Actual Wattage Lamp Fixture Fixture Lumens Efficiencyefficiency and conservation issues to date. The LBNL-designed energy efficient CFL

Page, Erik; Siminovitch, Michael

1997-01-01T23:59:59.000Z

6

Energy efficient alternatives to halogen torchieres  

Science Conference Proceedings (OSTI)

A series of novel energy efficient torchiere systems have been developed using compact fluorescent lamps (CFLs). These systems were studied photometrically and compared with the performance of traditional commercially available tungsten halogen sources. Gonio-photometric data and power assessments indicate that significant lighting energy savings can be obtained by utilizing CFL sources instead of standard tungsten halogen sources. This energy savings is jointly due to the higher source efficacy of the CFLs and the surprisingly poor performance of the imported 300 Watt halogen lamps. Experimental data shows that a 50 to 60 Watt CFL will effectively lumen match a variety of 300 Watt tungsten halogen sources with 5 to 10 times the efficacy. CFL torchieres have additional benefits of higher power quality and cooler lamp operating temperature, making them safer fixtures.

Siminovitch, M.; Marr, L.; Mitchell, J.; Page, E.

1997-03-01T23:59:59.000Z

7

Water-heating dehumidifier  

DOE Patents (OSTI)

A water-heating dehumidifier includes a refrigerant loop including a compressor, at least one condenser, an expansion device and an evaporator including an evaporator fan. The condenser includes a water inlet and a water outlet for flowing water therethrough or proximate thereto, or is affixed to the tank or immersed into the tank to effect water heating without flowing water. The immersed condenser design includes a self-insulated capillary tube expansion device for simplicity and high efficiency. In a water heating mode air is drawn by the evaporator fan across the evaporator to produce cooled and dehumidified air and heat taken from the air is absorbed by the refrigerant at the evaporator and is pumped to the condenser, where water is heated. When the tank of water heater is full of hot water or a humidistat set point is reached, the water-heating dehumidifier can switch to run as a dehumidifier.

Tomlinson, John J. (Knoxville, TN)

2006-04-18T23:59:59.000Z

8

Performance optimization of rotary dehumidifiers  

SciTech Connect

A rotary dehumidifier consists of a rotating porous matrix made of a desiccant with mechanically supporting materials. The dehumidification performance of a rotary dehumidifier wheel depends on its rotational speed, the sorption properties of the desiccant, the heat and mass transfer characteristics of the matrix, and the size of the dehumidifier. The effect of the rotational speed on the dehumidification performance of a rotary dehumidifier has been investigated by Zheng, Worek, and Novosel (1993). this paper extends that previous work and investigates the effects of desiccant sorption properties, the heat and mass transfer characteristics, and the size of the rotary dehumidifier on the dehumidification performance. The results show that the using desiccant materials in a rotary dehumidifier with different adsorption characteristics results in a wide variation in dehumidification performance. However, the maximum performance of a rotary dehumidifier occurs for a desiccant material having an isotherm shape that can be characterized to have a separation factor of 0.07. Also, as the desiccant moisture uptake increases, the dehumidifier performance also increases. However, the performance improvement for a desiccant matrix having a maximum moisture uptake of larger than 0.25 by weight is not significant. The heat and mass transfer properties and the size of rotary dehumidifier are characterized by the number of transfer units NTU. Generally, the larger the NTU, the better dehumidification performance. However, similar to the maximum moisture uptake, when the NTU is larger than 12, the performance will not improve significantly. Also, the dehumidifier with the most favorable adsorption characteristic has a slower rotational speed, which results in lower power requirements to rotate the desiccant wheel and smaller carry-over losses.

Zheng, W.; Worek, W.M. [Univ. of Chicago, IL (United States). Dept. of Mechanical Engineering; Novosel, D. [Gas Research Inst., Chicago, IL (United States)

1995-02-01T23:59:59.000Z

9

Solar powered dehumidifier apparatus  

SciTech Connect

A thermally insulated light transmitting housing forms a chamber containing a desiccant and having a first gas port open to the ambient and a second gas port connected by a two way valve to a volume to be dried. Solar energy transmitted through the housing heats and dries the desiccant. The increased air pressure due to the heating of the volume to be dried causes the air from the volume to be expelled through the valve into the chamber. The desiccant is then cooled by shielding it from solar energy before the volume cools thereby increasing its moisture absorbing capacity. Then the volume is allowed to cool drawing dehumidified air through the desiccant and the valve into the volume to be dried. This cycle is then repeated.

Jebens, Robert W. (Skillman, NJ)

1980-12-30T23:59:59.000Z

10

Building Technologies Office: Residential Dishwashers, Dehumidifiers, and  

NLE Websites -- All DOE Office Websites (Extended Search)

Residential Residential Dishwashers, Dehumidifiers, and Cooking Products, and Commercial Clothes Washers ANOPR Public Meeting to someone by E-mail Share Building Technologies Office: Residential Dishwashers, Dehumidifiers, and Cooking Products, and Commercial Clothes Washers ANOPR Public Meeting on Facebook Tweet about Building Technologies Office: Residential Dishwashers, Dehumidifiers, and Cooking Products, and Commercial Clothes Washers ANOPR Public Meeting on Twitter Bookmark Building Technologies Office: Residential Dishwashers, Dehumidifiers, and Cooking Products, and Commercial Clothes Washers ANOPR Public Meeting on Google Bookmark Building Technologies Office: Residential Dishwashers, Dehumidifiers, and Cooking Products, and Commercial Clothes Washers ANOPR

11

List of Dehumidifiers Incentives | Open Energy Information  

Open Energy Info (EERE)

Dehumidifiers Incentives Dehumidifiers Incentives Jump to: navigation, search The following contains the list of 159 Dehumidifiers Incentives. CSV (rows 1 - 159) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio (Gas) - Residential Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Residential Building Insulation Ceiling Fan Central Air conditioners Custom/Others pending approval Dehumidifiers Duct/Air sealing Heat pumps Lighting Motors Programmable Thermostats Windows Yes Alexandria Light and Power - Residential Energy Efficiency Rebate Program (Minnesota) Utility Rebate Program Minnesota Residential Central Air conditioners Clothes Washers Dehumidifiers Dishwasher Energy Mgmt. Systems/Building Controls Heat pumps Lighting

12

Dehumidifying Heat Pipes | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Dehumidifying Heat Pipes Dehumidifying Heat Pipes Dehumidifying Heat Pipes June 24, 2012 - 4:32pm Addthis In order to make a room comfortable in hot, humid climates, an air conditioner must lower the indoor humidity level as well as the air temperature. If an air conditioner fails to lower the humidity adequately, the air will be cool, but will feel uncomfortably damp. Inappropriately sized air conditioners are prone to this problem; large units quickly cool the air, but cycle off before they can properly dehumidify it. In extremely humid climates, even correctly sized air conditioning equipment could fail to maintain a home at a comfortable humidity level. One technology that addresses this problem is the dehumidifying heat pipe, a device that enables an air conditioner to dehumidify better and still

13

Experimental Results on Advanced Rotary Desiccant Dehumidifiers  

E-Print Network (OSTI)

The Solar Energy Research Institute (SERI) has developed the Cyclic Test Facility (CTF) to develop and validate analytical methods for evaluating and predicting the performance of advanced rotary dehumidifiers. This paper describes the CTF, the dehumidifiers tested at the CTF, and the analytical methods used. The results reported provide an engineering data base and a design tool for evaluating rotary dehumidifiers for desiccant cooling applications.

Barathan, D.; Parsons, J. M.; MaClaine-Cross, I.

1986-01-01T23:59:59.000Z

14

Experimental results on advanced rotary desiccant dehumidifiers  

DOE Green Energy (OSTI)

The Solar Energy Research Institute (SERI) has developed the Cyclic Test Facility (CTF) to develop and validate analytical methods for evaluating and predicting the performance of advanced rotary dehumidifiers. This paper describes the CTF, the dehumidifiers tested at the CTF, and the analytical methods used. The results reported provide an engineering data base and a design tool for evaluating rotary dehumidifiers for desiccant cooling applications.

Bharathan, D.; Parsons, J.; Maclaine-cross, I.

1986-08-01T23:59:59.000Z

15

Water-heating dehumidifier - Energy Innovation Portal  

A water-heating dehumidifier includes a refrigerant loop including a compressor, at least one condenser, an expansion device and an evaporator including an evaporator ...

16

Laboratory Performance Testing of Residential Dehumidifiers  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Laboratory Performance Laboratory Performance Testing of Residential Dehumidifiers Building America Stakeholders Meeting Jon Winkler March 2, 2012 2 Motivation * Solution: Performance map across a variety of operating conditions Dehumidifier Manufacturer Data ( ) in in RH T f e Performanc , = 80 F 60% RH Normalized Energy Factor Entering Drybulb Temperature (°C) Simulation Tool Input ? 3 ENERGY STAR Efficiency Criteria 1 2 3 4 0 30 60 90 120 150 Energy Factor (L/kWh) Dehumidifier Capacity (pints/day) ENERGY STAR v2.0 Efficiency Criteria Dehumidifiers Tested ENERGY STAR Products Non ENERGY STAR Products v3.0 Criteria 4 NREL Technical Report Laboratory Test Report for Six ENERGY STAR® Dehumidifiers Jon Winkler, Dane Christensen, and Jeff Tomerlin NREL/TP-5500-52791 December 2011

17

Dehumidifying Air for Cooling & Refrigeration: Nanotechnology Membrane-based Dehumidifier  

SciTech Connect

Broad Funding Opportunity Announcement Project: Dais is developing a product called NanoAir which dehumidifies the air entering a building to make air conditioning more energy efficient. The system uses a polymer membrane that allows moisture but not air to pass through it. A vacuum behind the membrane pulls water vapor from the air, and a second set of membranes releases the water vapor outside. The membranes high selectivity translates into reduced energy consumption for dehumidification. Dais design goals for NanoAir are the use of proprietary materials and processes and industry-standard installation techniques. NanoAir is also complementary to many other energy saving strategies, including energy recovery.

None

2010-10-01T23:59:59.000Z

18

NREL Tests Dehumidifiers, Defines Simplified Simulation Model (Fact Sheet)  

Science Conference Proceedings (OSTI)

Study of residential dehumidifiers results in practical performance curves for use in whole-building simulation tools.

Not Available

2012-05-01T23:59:59.000Z

19

Performance of cross-cooled desiccant dehumidifiers  

DOE Green Energy (OSTI)

A cross-cooled silica gel desiccant dehumidifier model was designed, built and tested. The performance of the unit was studied as a function of inlet process stream dew point, process stream and cooling stream flowrates and regeneration stream temperature and dew point. The tests were also simulated by a computer program and were compared to the experimental results.

Mei, V.C.; Lavan, Z.

1980-01-01T23:59:59.000Z

20

Laboratory Performance Testing of Residential Dehumidifiers (Presentation)  

SciTech Connect

Six residential vapor compression cycle dehumidifiers spanning the available range of capacities and efficiencies were tested in the National Renewable Energy Laboratory's Heating, Ventilating, and Air-Conditioning Systems Laboratory. Each was tested under a wide range of indoor air conditions to facilitate the development of performance curves for use in whole-building simulation tools.

Winkler, J.

2012-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Assessment of dehumidifier geometries for desiccant cooling systems  

DOE Green Energy (OSTI)

Five dehumidifier designs are evaluated in this report - three from existing prototype cooling systems (from AiResearch, IGT, and IIT) and two (from UCLA and SERI) that have not yet been tested in a complete cooling system. The basic principles of heat and mass regenerators and the requirements of the solar cooling application have been combined to generate a list of desirable characteristics for dehumidifiers. The five designs are described and compared quantitatively; compared characteristics are related directly to the list of desirable characteristics. System performance is considered as well as isolated dehumidifier parameters. Preliminary simulations indicate that a system using the SERI dehumidifier design could achieve a design-point COP greater than unity without causing significant increases in parasitic power, system size, or system cost, compared with existing prototypes. Because of the high potential of the wound-ribbon design, it is recommended that a research program be carried out to fully characterize this type of dehumidifier.

Barlow, R.S.

1983-06-01T23:59:59.000Z

22

Experimental study of an advanced silica gel dehumidifier  

DOE Green Energy (OSTI)

This report contains results of work done to experimentally characterize the performance of an advanced, rotary, desiccant dehumidifier and to develop and validate analytical methods for evaluating its performance in air-conditioning systems. A facility, the Cyclic Test Facility, and a test and analysis procedure were developed to evaluate the performance of the dehumidifier. A series of tests was undertaken to understand the simultaneous heat- and mass-transfer processes. An advanced dehumidifier test article was tested under cyclic operation to fully characterize its performance. Brief accounts of this facility, with its hardware and instrumentation, and detailed accounts of the test data and data reduction and analysis methods are presented. The data provide an engineering data base for evaluating rotary dehumidifiers for cooling applications. The dehumidifier's performance, as measured by the effectiveness, agreed with theory to within plus or minus 10%. 16 refs., 16 figs., 1 tab.

Bharathan, D.; Parsons, J.M.; Maclaine-cross, I.L.

1987-11-01T23:59:59.000Z

23

A desiccant dehumidifier for electric vehicle heating  

DOE Green Energy (OSTI)

Vehicle heating requires a substantial amount of energy. Engines in conventional cars produce enough waste heat to provide comfort heating and defogging/defrosting, even under very extreme conditions. Electric vehicles (EVs), however, generate little waste heat. Using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. Water vapor generated by the vehicle passengers is in large part responsible for the high heating loads existing in vehicles. In cold climates, the generation of water vapor inside the car may result in water condensation on the windows, diminishing visibility. Two strategies are commonly used to avoid condensation on windows: windows are kept warm, and a large amount of ambient air is introduced in the vehicle. Either strategy results in a substantial heating load. These strategies are often used in combination, and a trade-off exists between them. If window temperature is decreased, ventilation rate has to be increased. Reducing the ventilation rate requires an increase of the temperature of the windows to prevent condensation. An alternative solution is a desiccant dehumidifier, which adsorbs water vapor generated by the passengers. Window temperatures and ventilation rates can then be reduced, resulting in a substantially lower heating load. This paper explores the dehumidifier heating concept. The first part shows the energy savings that could be obtained by using this technology. The second part specifies the required characteristics and dimensions of the system. The results indicate that the desiccant system can reduce the steady-state heating load by 60% or more under typical conditions. The reduction in heating load is such that waste heat may be enough to provide the required heating under most ambient conditions. Desiccant system dimensions and weight appear reasonable for packaging in an EV.

Aceves, S.M.; Smith, J.R.

1996-09-01T23:59:59.000Z

24

Performance predictions of silica-gel desiccant dehumidifiers  

DOE Green Energy (OSTI)

The analysis of a cross-cooled desiccant dehumidifier using silica gel in the form of sheets is described. This unit is the principal component of solar powered desiccant air conditioning system. The mathematical model has first been formulated describing the dynamics of the dehumidifier. The model leads to a system of nonlinear coupled heat and mass transfer equations for the sorption processes and linear heat transfer equations for the purging processes. The model accounts for the gas film resistance and for the moisture diffusion in the desiccant. The governing equations are solved by a finite difference scheme to obtain periodic steady state solutions. The accuracy of the theoretical predictions is ascertained by comparing them with the experimental results. The performance of the dehumidifier, for a chosen set of initial conditions and dehumidifier parameters, has also been given.

Mathiprakasam, B.; Lavan, Z.

1980-01-01T23:59:59.000Z

25

Development of a solar desiccant dehumidifier. Third technical progress report  

DOE Green Energy (OSTI)

This program is aimed at the development of a solar desiccant dehumidifier featuring a rotary bed of granular silica gel and a rotary regenerator. Design, fabrication, performance, commercialization studies, and test stand development are described in detail. (WHK)

Gunderson, M.E.

1979-06-12T23:59:59.000Z

26

Heat and mass transfer analysis of a desiccant dehumidifier matrix  

DOE Green Energy (OSTI)

This report documents the SERI Single-Blow Test Facility's design, fabrication, and testing for characterizing desiccant dehumidifiers for solar cooling applications. The first test article, a silica-gel parallel-plate dehumidifier with highly uniform passages, was designed and fabricated. Transient heat and mass transfer data and pressure drop data across the dehumidifier were obtained. Available heat and mass transfer models were extended to the parallel-place geometry, and the experimental data were compared with model predictions. Pressure drop measurements were also compared with model predictions of the fully developed laminar flow theory. The comparisons between the lumped-capacitance model and the experimental data were satisfactory. The pressure drop data compared satisfactorily with the theory (within 15%). A solid-side resistance model that is more detailed and does not assume symmetrical diffusion in particles was recommended for performance. This study has increased our understanding of the heat and mass transfer in silica gel parallel-plate dehumidifiers.

Pesaran, A.A.

1986-07-01T23:59:59.000Z

27

Aperture lamp  

DOE Patents (OSTI)

A discharge lamp includes means for containing a light emitting fill, the fill being capable of absorbing light at one wavelength and re-emitting the light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill; means for exciting the fill to cause the fill to emit light; and means for reflecting some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length. Another discharge lamp includes an envelope; a fill which emits light when excited disposed in the envelope; a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light; and a reflective ceramic structure disposed around the envelope and defining an light emitting opening, wherein the structure comprises a sintered body built up directly on the envelope and made from a combination of alumina and silica.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD)

2003-01-01T23:59:59.000Z

28

Experimental Investigation of the Padding Tower for Air Dehumidifier  

E-Print Network (OSTI)

Air conditioning with all fresh air is founded on the principle of dehumidifying by liquid desiccant. It has the characteristics of being clean, power-saving, easy to operate, and requiring low-grade heat. It is suitable for applying waste heat, and solar power as the heat source for regeneration. Hence, this system has a great latent potential for energy savings and environmental protection. The system chooses the padding tower as a dehumidifier and regenerator, which are often used in petrochemical industry. The system chooses a padding tower as a dehumidifier, and LiCl-Water as a liquid desiccant. The vapor in the air is absorbed by the spray of the LiCl solution, and then the absorbed vapor will be released by heating the absorbent. These processes form the circle of absorptive refrigeration operating in atmospheric pressure. This paper describes studies on the theory and experiment of the padding tower of the dehumidifying air conditioning, including selecting different padding and measuring the speed of the air flow and the solution flow and the pressure drop between the layers of the padding. The experimental and computational results indicate that the design parameters of the padding tower significantly influence the characteristics of the liquid desiccant air conditioning. Of these design parameters, the framework of the padding tower, ratio of the air and the concentration of the inlet solution is largest through the tower, the temperature and effects of the dehumidifying capability of the tower.

Wang, J.; Liu, J.; Li, C.; Zhang, G.; An, S.

2006-01-01T23:59:59.000Z

29

Performance of a cross-cooled desiccant dehumidifier prototype  

DOE Green Energy (OSTI)

The cross-cooled dehumidifier prototype was constructed in the form of a cube with a side dimension of 0.6 m. The cross-cooling was achieved by passing air through rectangular channels perpendicular to process channels which are lined with desiccant sheets consisting of 9..mu..m Syloid 63/sup TM/ silica gel held in a Teflon web. The process for the manufacture of the silica gel sheets was developed at the Illinois Institute of Technology. The dehumidifier prototype was installed in a test system that simulated the performance of a cross-cooled desiccant cooling system and monitored the performance of the prototype. The dehumidifier prototype was operated over a wide range of operating conditions which would be typically encountered in the field installation of such a system. Variables measured were the moisture cycled, cooling capacity, total cooling capacity and coefficient of performance.

Worek, W.M.; Lavan, Z.

1981-08-01T23:59:59.000Z

30

Lamp Divisions  

Office of Legacy Management (LM)

--- --- /A;; i :' r%i;in~house ilEc;' i:Z3:~cra:ion Lamp Divisions , _.. (I +i. 0 :,,,rg. . I . . -= i?e p/q! qe)-' &se pw E.rcale?l iev, Je!sey 07m March 20, 1 gs? ::r . J. A. Jones I ti. 5. Muclear Regulatory Commission .> = ..- haterials Licensing Branch -s - ,.I, - - Division of Fuel Cycle and hateri al Safety LY. , $2 - _ . ' -' . 3 _- - Yeshington, C. C. 2@555 - :_ :--, =-- -- .-?J -.: y...., : :- 7 Dear Mr. Jones : y-- --, ? . *I 2=15 2 r; X -P The following is our final report of the decontamination efZor?s takz in our Bui Iding 7 basement and wi 11 also serve to update our report i& November 12, 1980. As stated in NRC' s report of December 22, 1983, two closeout inspect ions were conducted by your King of Prussia off i ce on November 21 and December 2,

31

LED lamp  

SciTech Connect

There is herein described a lamp for providing white light comprising a plurality of light sources positioned on a substrate. Each of said light sources comprises a blue light emitting diode (LED) and a dome that substantially covers said LED. A first portion of said blue light from said LEDs is transmitted through said domes and a second portion of said blue light is converted into a red light by a first phosphor contained in said domes. A cover is disposed over all of said light sources that transmits at least a portion of said red and blue light emitted by said light sources. The cover contains a second phosphor that emits a yellow light in response to said blue light. The red, blue and yellow light combining to form the white light and the white light having a color rendering index (CRI) of at least about 80.

Galvez, Miguel; Grossman, Kenneth; Betts, David

2013-11-12T23:59:59.000Z

32

Laboratory Test Report for Six ENERGY STAR Dehumidifiers  

Science Conference Proceedings (OSTI)

This report documents the measured performance of six residential ENERGY STAR vapor compression dehumidifiers. The performance of each was measured over a wide range of inlet air conditions and fit to a numerical model for capacity and efficiency. Performance curves were developed for use in EnergyPlus. Test data from all six dehumidifiers were also fit to generic performance curves. This work can be used by energy modelers and equipment manufacturers to understand how current products will operate in a wide range of environments, and to develop advanced space conditioning systems for efficient, safe, durable and healthy homes.

Winkler, J.; Christensen, D.; Tomerlin, J.

2011-12-01T23:59:59.000Z

33

Statistical analysis of a silica gel rotary dehumidifier  

SciTech Connect

A regression analysis was conducted on experimental data obtained during the testing of a solid desiccant dehumidifier at the Solar Energy Research Institute (SERI has since been renamed the National Renewable Energy Laboratory). The data obtained was studied using statistical techniques to determine the regression equation for the temperature and humidity at the processed air outlet of the dehumidifier. These variables determine the cooling capacity and efficiency (Coefficient of Performance) of any desiccant cooling cycle. The analysis is used to determine the relative impact the input parameters have on the outlet temperature and humidity.

Kini, A.; Waugaman, D.G.; Kettleborough, C.F. (Texas A and M Univ., College Station (United States))

1993-01-01T23:59:59.000Z

34

Analysis of a Fabric/Desiccant Window Cavity Dehumidifier  

E-Print Network (OSTI)

This paper presents the results of an exploratory study of a fabric/desiccant window cavity dehumidifier system for possible use in commercial buildings. The objective was to evaluate fabrics commonly used in buildings, and system concepts that employ these fabrics, which can be used to dehumidify room air. We developed a first-order energy/mass balance model to determine the performance of a window cavity dehumidifier that uses silica gel encapsulated in a fabric matrix rotating on a belt alternately through dehumidification and regeneration chambers; the modeling effort was supplemented by environmental chamber measurements of the moisture absorption characteristics of 16 fabric/desiccant combinations. We ran the model for a typical office building module, for outside air design conditions characteristic of the most difficult humidity regime in Texas. Two flow configurations, outside air and return air, were evaluated to determine the capability of such a system to dehumidify the air streams under consideration. Issues addressed included the physical limitations on the amount of desiccant that can be included in this configuration and the degree of dehumidification achievable.

Hunn, B. D.; Grasso, M. M.; Vadlamani, V.

1994-01-01T23:59:59.000Z

35

Development of an Energy Efficient Desiccant Dehumidifier : Final Report.  

SciTech Connect

Humidity control in space conditioning has received a good deal of attention in the past twenty or so years. Perhaps the most familiar application is the use of humidifiers in the winter months. Of equal concern is the use of air conditions and dehumidifiers in the summer months. High humidity levels in summer months require lower coil temperatures in order to achieve human comfort levels, and may result in significant product and property damage if humidity levels are not controlled at appropriate level. This study addresses the solid desiccant dehumidifier using IR heaters as an energy efficient desiccant dehumidifier (EEDD). The study is divided into two phases; Phase 1 -- Application assessment; and Phase 2: Prototype design, manufacture, and testing. Phase 1 addresses the total electrical energy usage by all possible applications of the EEDD and evaluates the energy performance of the EEDD in terms of its percentage energy savings compared to the conventional vapor compression cooling and also with the state-of-the-art desiccant dehumidifiers. During Phase 2, a functional EEDD prototype unit was designed and manufactured. The work of Phase 2 was divided into four tasks: Task 1, conceptual design; Task 2, mechanical (blueprint) design; Task 3, manufacture and factory testing; and Task 4, performance testing. 17 refs., 21 figs., 30 tabs.

Relwani, Suresh M.; Moschandreas, Demetrios J.

1990-04-01T23:59:59.000Z

36

Facility design for cyclic testing of advanced solid desiccant dehumidifiers  

DOE Green Energy (OSTI)

The development of high performance components is required to reach the goal of desiccant cooling system cost-competitiveness with conventional vapor compensation air conditioning systems. SERI has designed a laminar flow, parallel passage dehumidifier that has this potential. The goal of SERI's desiccant cooling research program is to fully characterize experimentally the performance of the parallel passage dehumidifier under a wide range of operating conditions, investigate improvements in design, and verify existing models of dehumidifier performance against experimental results. This report documents the design of the SERI Desiccant Cooling Test Facility for performing the above testing. With slight modifications, the testing can be used for testing other desiccant cooling system components. The dehumidifier processes and the parameters and variables needed to control and characterize its performance are presented. The physical layout of the test loop and instrumentation for monitoring the operating conditions and dehumidifer performance and the controls for maintaining the operating conditions are specified. The computerized data acquisition system conversion equations and an error analysis of measurement variables are also presented.

Schlepp, D.; Schultz, K.; Zangrando, F.

1984-08-01T23:59:59.000Z

37

Shutdown Protection of Steam Turbines Using Dehumidified Air  

Science Conference Proceedings (OSTI)

EPRI research has determined that proper protection of the steam turbine during shutdown periods is essential to the prevention of damage by stress corrosion cracking and corrosion fatigue. This report provides information on both the incipient damage of improper shutdown and techniques for assessing and applying dehumidified air for shutdown protection.

2008-03-26T23:59:59.000Z

38

Laboratory Test Report for Six ENERGY STAR Dehumidifiers  

NLE Websites -- All DOE Office Websites (Extended Search)

Test Report for Six Test Report for Six ENERGY STAR ® Dehumidifiers Jon Winkler, Ph.D., Dane Christensen, Ph.D., and Jeff Tomerlin Technical Report NREL/TP-5500-52791 December 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308 Laboratory Test Report for Six ENERGY STAR ® Dehumidifiers Jon Winkler, Ph.D., Dane Christensen, Ph.D., and Jeff Tomerlin Prepared under Task No. BE11.0201 Technical Report NREL/TP-5500-52791 December 2011 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government.

39

High-performance dehumidifier for solar desiccant cooling systems  

DOE Green Energy (OSTI)

An advanced-design, one-tenth-scale dehumidifier for use in residential solar desiccant-cooling systems has been built and tested. The new dehumidifier was designed using a parallel-passage geometry, where air flows through channels formed by walls coated with fine-ground silica gel desiccant. This concept has a high heat and mass transfer effectiveness and promises to double the coefficient of performance of the desiccant cooling system to 1.1 kW cooling output/kW thermal input. The parallel-passage design was found to have very low pressure drop, typically 20 Pa (.08 in. water) at design conditions. The low fan power required to drive such low pressure drop components indicates that electrical COP's in the range of 8.0 to 8.2 kW cooling output/kW electrical input are possible. Results presented include parametric studies of the effect of conditions such as temperature and humidity and design parameters such as desiccant particle size and channel spacing on dehumidifier performance.

Schlepp, D.

1983-05-01T23:59:59.000Z

40

Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

Electric lighting constitutes approximately 21-23 % of the electric grid load in the United States. The higher energy and maintenance costs of incandescent lamps, combined with the favorable economics of high-efficiency compact fluorescent lamps (CFLs), are making CFLs the increasingly popular choice for both residential and commercial lighting. Utility incentive and rebate programs to stimulate CFL use and the beginnings of a ban on incandescent lamps are enhancing CFL penetration levels in these enviro...

2009-12-17T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Development of a solar desiccant dehumidifier. Second technical progress report  

SciTech Connect

Research and development of a solar desiccant dehumidifier featuring a rotary bed of granular silica gel and a rotary regenerator for air conditioning is described. The results of the system optimization studies are presented. The studies involved an extensive investigation of the energy saving potential and economic viability of the solar desiccant dehumidifier in different locations in the United States. Conventional electric vapor compression, and solar absorption and Rankine systems also were investigated for comparison. In general, it was found that the solar desiccant equipment, either by itself or in a hybrid system with an electric vapor compression air conditioner, is economically viable for all three locations considered. Substantial energy savings can be effected as well. Seal tests done at AiResearch to develop practical dynamic air seals are described. Leakage and friction tests were performed on a variety of material combinations and configurations. Dacron felt and silicone rubber were found to give an acceptable combination of leakage, friction, and cost characteristics. As part of the commercialization studies for the desiccant equipment, a questionnaire was sent to residential air conditioning equipment distributors. The results of the questionnaire are presented. The specifications and drawings for the 1.5-ton prototype are included. (WHK)

Gunderson, M.E.; Hwang, K.C.; Railing, S.M.; Rousseau, J.

1978-11-10T23:59:59.000Z

42

Jacketed lamp bulb envelope  

DOE Patents (OSTI)

A jacketed lamp bulb envelope includes a ceramic cup having an open end and a partially closed end, the partially closed end defining an aperture, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material at least partially covering a portion of the bulb not abutting the aperture. The reflective ceramic material may substantially fill an interior volume of the ceramic cup not occupied by the bulb. The ceramic cup may include a structural feature for aiding in alignment of the jacketed lamp bulb envelope in a lamp. The ceramic cup may include an external flange about a periphery thereof. One example of a jacketed lamp bulb envelope includes a ceramic cup having an open end and a closed end, a ceramic washer covering the open end of the ceramic cup, the washer defining an aperture therethrough, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material filling an interior volume of the ceramic cup not occupied by the bulb. A method of packing a jacketed lamp bulb envelope of the type comprising a ceramic cup with a lamp bulb disposed therein includes the steps of filling the ceramic cup with a flowable slurry of reflective material, and applying centrifugal force to the cup to pack the reflective material therein.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Gitsevich, Aleksandr (Gaithersburg, MD); Bass, Gary K. (Mt. Airy, MD); Dolan, James T. (Frederick, MD); Kipling, Kent (Gaithersburg, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Leng, Yongzhang (Damascus, MD); Levin, Izrail (Silver Spring, MD); Roy, Robert J. (Frederick, MD); Shanks, Bruce (Gaithersburg, MD); Smith, Malcolm (Alexandria, VA); Trimble, William C. (Columbia, MD); Tsai, Peter (Olney, MD)

2001-01-01T23:59:59.000Z

43

Performance Test and Energy Saving Analysis of a Heat Pipe Dehumidifier  

E-Print Network (OSTI)

Heat pipe technology applied to ventilation, dryness, and cooling and heating radiator in a building is introduced in this paper. A new kind of heat pipe dehumidifier is designed and tested. The energy-saving ratio with the heat pipe dehumidifier ranges from 11.81% to 30.34% compared with the normal dehumidifier, according to the performance testing. The dehumidification capacity and the surface cooler power increases, but the energy saving ratio is reduced with the increase of air relative humidity, dry bulb temperature and air quantity

Zhao, X.; Li, Q.; Yun, C.

2006-01-01T23:59:59.000Z

44

LiCl Dehumidifier LiBr absorption chiller hybrid air conditioning system with energy recovery  

SciTech Connect

This invention relates to a hybrid air conditioning system that combines a solar powered LiCl dehumidifier with a LiBr absorption chiller. The desiccant dehumidifier removes the latent load by absorbing moisture from the air, and the sensible load is removed by the absorption chiller. The desiccant dehumidifier is coupled to a regenerator and the desiccant in the regenerator is heated by solar heated hot water to drive the moisture therefrom before being fed back to the dehumidifier. The heat of vaporization expended in the desiccant regenerator is recovered and used to partially preheat the driving fluid of the absorption chiller, thus substantially improving the overall COP of the hybrid system.

Ko, Suk M. (Huntsville, AL)

1980-01-01T23:59:59.000Z

45

Analysis of a Flat-Plate, Liquid-Desiccant, Dehumidifier and Regenerator.  

E-Print Network (OSTI)

??A numerical model for isothermal and non-isothermal flat-plate liquid-desiccant dehumidifiers and regenerators was developed and implemented. The two-dimensional model takes into account the desiccant, water (more)

Mesquita, Lucio Cesar De Souza

2008-01-01T23:59:59.000Z

46

Performance predictions of silica-gel desiccant dehumidifiers. Technical report No. 3  

SciTech Connect

The analysis of a cross-cooled desiccant dehumidifier using silica gel in the form of sheets is described. This unit is the principal component of solar powered desiccant air conditioning system. The mathematical model has first been formulated describing the dynamics of the dehumidifier. The model leads to a system of nonlinear coupled heat and mass transfer equations for the sorption processes and linear heat transfer equations for the purging processes. The model accounts for the gas film resistance and for the moisture diffusion in the desiccant. The governing equations are solved by a finite difference scheme to obtain periodic steady state solutions. The accuracy of the theoretical predictions is ascertained by comparing them with the experimental results. The performance of the dehumidifier, for a chosen set of initial conditions and dehumidifier parameters, has also been given.

Mathiprakasam, B.; Lavan, Z.

1980-01-01T23:59:59.000Z

47

Fluorescent lamp ballast  

SciTech Connect

An electronic ballast is described having at least a first and second terminal for engaging the filaments of at least one fluorescent lamp which requires a breakdown voltage to ignite the lamp and a maintaining voltage for maintaining ionization therewithin, the electronic ballast comprising: a direct current voltage source; a transistor; a transformer having a primary winding separated into a first winding, a second winding, a third winding, and a fourth winding; the first winding connected between the voltage source and the first terminal; the second winding connected between the two terminals; the third winding connected between the second terminal and to both the transistor and to ground; the fourth winding connected between ground and the transistor; the lamp being parallel to the second winding when the lamp filaments engages the ballast terminals.

Ureche, A.

1987-08-25T23:59:59.000Z

48

Electronic Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses the fastest growing energy efficient light source the electronic compact fluorescent lamp (CFL). Business and technical market factors (Chapter 2) explain the past and future growth of the CFL market while emphasizing future technical improvements along with discussion of the importance of utility involvement in helping their customers make the switch from incandescent lamps to CFLs. The basic CFL technology is covered in Chapter 3 including test results for selected ...

2007-12-18T23:59:59.000Z

49

Magnetic fluorescent lamp  

DOE Patents (OSTI)

The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly is enhanced by providing means for establishing a magnetic field with lines of force along the path of electron flow through the bulb of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

Berman, S.M.; Richardson R.W.

1983-12-29T23:59:59.000Z

50

NREL Tests Dehumidifiers, Defines Simplified Simulation Model (Fact Sheet), NREL Highlights, Research & Development, NREL (National Renewable Energy Laboratory)  

NLE Websites -- All DOE Office Websites (Extended Search)

residential dehumidifiers residential dehumidifiers results in practical performance curves for use in whole-building simulation tools. Dehumidifiers remove moisture from a home's indoor environment, thereby increasing occupant comfort, improving air quality, and reducing the likelihood of mold, rot, and dust mites. To help energy professionals more easily evaluate this technology for the market, National Renewable Energy Laboratory (NREL) researchers tested the efficiency and capacity of a variety of dehumidifiers and developed a generalized approach to simulate any residential dehumidifier. The test results and modeling method are documented in a new report. Typically, dehumidifiers are only rated at a single temperature and humidity, so rating data alone cannot determine whether a product will meet the moisture removal

51

Fluorescent lamp ballast  

SciTech Connect

This patent describes an electronic ballast unit for a fluorescent lamp comprising: a circuit assembly having a pair of voltage input terminal and a first inductor and a capacitor in series relationship with each other to form a series resonant circuit. The circuit is adapted to be coupled to a fluorescent lamp to provide a starting voltage for the lamp; and a second inductor connected in shunt relationship to the first inductor and connected to the other input terminal. There is a core on which the first inductor and the second inductor are mounted. The core inductively couples the inductors with each other and are shaped to reduce core losses to minimize the increase of temperature of the core; the core is of a generally H-shaped configuration, and means of opposite ends of the H-shaped core to complete the magnetic flux path for each inductor, respectively.

Boyd, G.D.

1987-03-31T23:59:59.000Z

52

Convective heat and mass transfer in compact regenerative dehumidifiers  

Science Conference Proceedings (OSTI)

Regular-density silica gel is identified as the candidate desiccant for regenerative dehumidification of humid air operating at low-regeneration temperatures and high-process humidities. The literature on the equilibrium sorption uptake of water vapor by R. D. silica gel is reviewed in this work, and a large number of experimental sorption data is collected from various technical reports. The Dubinin-Polanyi sorption theory for microporous adsorbents is discussed and applied to the sorptive data. A graphical presentation of the experimental data establishes the characteristic curve for the sorption of water vapor on silica gel. The Dubinin-Astakhov correlation is used to represent the equilibrium sorption isotherm and values for the characteristic sorption energies are determined by curve fitting with the experimental data. An accurate, generalized isotherm equation for the sorption of water vapor on regular density silica gel is presented in the first part of this work. The second part of this work presents an analytical and experimental investigation of the transient heat and mass transfer in laminar flow of humid air over a silica gel surface. Experimental results are presented for the transient response of a parallel-plate dehumidifier matrix in single-blow type experiments.

Van den Buick, E.

1987-01-01T23:59:59.000Z

53

Cross-cooled dehumidifier model test results and computer simulations  

DOE Green Energy (OSTI)

Research on the development of a solar operated cross-cooled desiccant cooling system is described. A 15 cm x 15 cm x 15 cm (6'' x 6'' x 6'') cross-cooled silica gel desiccant dehumidifier model was designed, built and tested. The process of producing the silica gel sheets, the design and construction of the unit, the test setup and the test procedures are described in detail. A total of twenty tests were performed to determine the effect of inlet process stream dew point, process stream and cooling stream flowrates and regeneration stream temperature and dew point, on the performance of the unit. The test results show that the unit performance improves with increasing regeneration temperature, process stream flowrate and process air inlet dew point. The unit performance decreases with increase of the regeneration stream dew point. The results clearly show that the process stream inlet dew point is the dominating factor and that the concept of cross-cooling works very well. With moderate cross-cooling, the unit performance can increase over 50%. All tests were simulated by a computer program. The experimental and theoretical results are in very good agreement.

Mei, V.; Lavan, Z.

1979-11-01T23:59:59.000Z

54

2X Incandescent Lamp Technology  

Science Conference Proceedings (OSTI)

The incandescent lamp was developed during the 1800s, largely reaching the design of the traditional incandescent lamp as we know it by the late 1800s.This lamp remained largely unchanged for years, providing most commercial and residential lighting demands into the 1950s and residential lighting into the 2000s. Asnew lighting technologies became available, the low efficacy, measured in lumens per watt, of the traditional incandescent lamp became an issue which many wanted to ...

2012-11-01T23:59:59.000Z

55

Facilities for testing desiccant materials and geometries of dehumidifiers for solar-regenerated desiccant cooling systems  

SciTech Connect

Four experimental test facilities for characterizing the performance of solid desiccant materials and dehumidifier matrices which have the potential to be used in solar-regenerated desiccant cooling systems are reviewed. The water equilibrium capacity and sorption rates of desiccant materials, depending on their form, can be either measured with a quartz crystal microbalance or a desiccant sorption test facility. Pressure drop, heat- and mass-transfer rates and transient equilibrium dehumidification capacity of a dehumidifier matrices are measured in a desiccant heat and mass transfer test facility. The performance and steady state dehumidification capabilities of prototype dehumidifier components under realistic conditions are measured in a desiccant cyclic test facility. The description of the test apparatus, experimental procedure, measurement errors, and typical results for the four test facilities are presented here. 15 refs., 9 figs., 1 tab.

Pesaran, A.A.; Bingham, C.E.

1988-12-01T23:59:59.000Z

56

Testing of a solar powered cooling system using cross-cooled desiccant dehumidifiers  

DOE Green Energy (OSTI)

A solar powered desiccant cooling system using two fixed bed silica gel dehumidifiers has been designed, built and is being tested. The dehumidifiers, 0.6 x 0.6 x 0.6 m each, are constructed of 80 channels lined with 64 m/sup 2/ of 1.5 mm thick silica gel sheets. The bed is cooled by air flowing in an equal number of perpendicular channels. Both sets of channels are two mm wide, the dehumidifiers undergo adsorption, preheating, desorption and precooling in a cyclic fashion. The cooling capacity of the experimental system is one ton at ARI design conditions. The system has a high cooling capacity, high COP, low parasitic power consumption and requires low regeneration temperatures.

Monnier, J.B.; Worek, W.M.; Lavan, Z.

1981-01-01T23:59:59.000Z

57

Fluorescent lamp dimming adaptor kit  

SciTech Connect

An add-on fluorescent lamp dimming adaptor is described for connecting to a conventional nondimming ballast in a fluorescent lighting system, the system including a source of ac voltage. The ballast has terminals for connecting to a fluorescent lamp, the adaptor comprising: a switching module adapted to be coupled to the terminals for switching current from the lamp, the switching module being connected in parallel with the lamp to divert current from the lamp when the switching module conducts; and a level control coupled to the switching module, the level control controlling the conductive state of the switching module to vary the current in the lamp according to a dimming control signal supplied to the level control, the level control causing the switching module to switch at a frequency in the range of 300 hertz and higher during times that the lamp current is being varied.

Alley, R.P.

1987-07-21T23:59:59.000Z

58

Flash Lighting with Fluorescent Lamp.  

E-Print Network (OSTI)

??A flash lighting circuit with the fluorescent lamp is designed to produce lighting flicker by means of controlling the operating frequency and the duty-ratio of (more)

Hsieh, Horng

2005-01-01T23:59:59.000Z

59

Fixture conditions affect lamp performance  

SciTech Connect

This article discusses the major parameters that affect fluorescent lamp performance under fixture conditions. These parameters include fixture type, and HVAC integration, which directly determine the minimum lamp wall temperature (MLWT), and therefore, the resulting light output of the lamp/ballast system. Experimental data is presented showing that the lumen output of the lamp/ballast system can vary by as much as 20% and that the system efficacy can vary by 10% depending upon the type of fixture and HVAC system employed. 4 refs., 5 figs., 1 tab.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.

1986-11-01T23:59:59.000Z

60

Experimental studies of heat and mass exchange in parallel-passage rotary desiccant dehumidifiers for solar cooling applications  

DOE Green Energy (OSTI)

This report presents results of work done to experimentally characterize the performance of rotary desiccant dehumidifiers and to develop and validate analytical methods for evaluating their performance in air-conditioning systems. A facility, the Cyclic Test Facility, and a test-and-analysis procedure were developed to evaluate the performance of the rotary dehumidifiers. Experiments were performed to develop a basic understanding of the simultaneous heat- and mass-transfer processes in the dehumidifiers. Two test articles were tested under cyclic operation to characterize their performance. Detailed accounts of the Cyclic Test Facility, its hardware and instrumentation, the two test articles, and data reduction and analysis methods are provided. The data provide an engineering data base for evaluating rotary desiccant dehumidifiers for cooling applications. 46 refs., 26 figs., 3 tabs.

Bharathan, D.; Parsons, J.M.; Maclaine-cross, I.L.

1987-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Inductive tuners for microwave driven discharge lamps  

DOE Patents (OSTI)

An RF powered electrodeless lamp utilizing an inductive tuner in the waveguide which couples the RF power to the lamp cavity, for reducing reflected RF power and causing the lamp to operate efficiently.

Simpson, James E. (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

62

Information Resources: LED Replacement Lamps: Current Performance...  

NLE Websites -- All DOE Office Websites (Extended Search)

incandescent lamps (e.g., A-lamps), and provided an update on ENERGY STAR criteria for LED integral replacement lamps - currently in its second draft. Robert Lingard of Pacific...

63

A projective LED dental lamp design.  

E-Print Network (OSTI)

??Halogen lamps are mostly applied as a light source to the traditional lamp for medical treatment due to its proper color temperature, but it has (more)

Chung, Yu-Lin

2011-01-01T23:59:59.000Z

64

On the use of the parabolic concentration profile assumption for a rotary desiccant dehumidifier  

SciTech Connect

The current work describes a model for a desiccant dehumidifier which uses a parabolic concentration profile assumption to model the diffusion resistance inside the desiccant particle. The relative merits of the parabolic concentration profile model compared with widely utilized rotary desiccant wheel models are discussed. The periodic steady-state parabolic concentration profile model developed is efficient and can accommodate a variety of materials. These features make it an excellent tool for design studies requiring repetitive desiccant wheel simulations. A quartic concentration profile assumption was also investigated which yielded a 2.8 percent average improvement in prediction error over the parabolic model.

Chant, E.E. [Univ. of Turabo, Gurabo (Puerto Rico); Jeter, S.M. [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

1995-02-01T23:59:59.000Z

65

Comparison of the performance of open cycle air conditioners utilizing rotary desiccant dehumidifiers  

DOE Green Energy (OSTI)

This paper presents the results of an investigation of open cycle cooling systems using rotary desiccant dehumidifiers. Three systems, the ventilation, recirculation, and Dunkle cycles have been modeled. The performance of these systems coupled with an air-based solar system has been determined using TRNSYS simulations of system operation in four representative US climates. The system COP, fraction of the total cooling load met by the desiccant system, and fraction of the thermal energy provided by solar energy are compared. An assessment of the effect of climate and system parameters on the relative performance of the three system configurations is made. It is shown that in order to meet residential loads of 7 to 11 kW with a COP on the order of unity, systems with high effectiveness must be employed. These systems were also found to perform well when operated solely with a solar thermal input.

Jurinak, J.J.; Beckman, W.A.

1985-01-01T23:59:59.000Z

66

SERI Desiccant Cooling Test Facility. Status report. Preliminary data on the performance of a rotary parallel-passage silica-gel dehumidifier  

DOE Green Energy (OSTI)

This report describes the SERI Desiccant Cooling Test Facility. The facility can test bench-scale rotary dehumidifiers over a wide range of controlled conditions. We constructed and installed in the test loop a prototype parallel-passage rotary dehumidifier that has spirally wound polyester tape coated with silica gel. The initial tests gave satisfactory results indicating that approximately 90% of the silica gel was active and the overall Lewis number of the wheel was near unity. The facility has several minor difficulties including an inability to control humidity satisfactorily and nonuniform and highly turbulent inlet velocities. To completely validate the facility requires a range of dehumidifier designs. Several choices are available including constructing a second parallel-passage dehumidifier with the passage spacing more uniform.

Schultz, K.J.

1986-04-01T23:59:59.000Z

67

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

certain lighting system components, but with only minor exceptions (torchieres, ceiling fan light kits, exit signs, traffic signals, and metal halide lamp fixtures), has not...

68

Lamp bulb with integral reflector  

SciTech Connect

An improved electrodeless discharge lamp bulb includes an integral ceramic reflector as a portion of the bulb envelope. The bulb envelope further includes two pieces, a reflector portion or segment is cast quartz ceramic and a light transmissive portion is a clear fused silica. In one embodiment, the cast quartz ceramic segment includes heat sink fins or stubs providing an increased outside surface area to dissipate internal heat. In another embodiment, the quartz ceramic segment includes an outside surface fused to eliminate gas permeation by polishing.

Levin, Izrail (Silver Spring, MD); Shanks, Bruce (Gaithersburg, MD); Sumner, Thomas L. (Wheaton, MD)

2001-01-01T23:59:59.000Z

69

Design and testing a solar cooling system employing liquid desiccants: Dehumidifier experiments in Colorado State University Solar House II: Final report, 1986--1987  

DOE Green Energy (OSTI)

A nominal 3-ton (10.5-kW) lithium bromide, open-cycle desiccant cooling system has been designed, installed, and operated. This experimental system dehumidifies ambient air in a packed bed utilizing an aqueous solution of lithium bromide. The absorbent solution is distributed by spray nozzles and flows countercurrent to the air. The dilute solution exiting the dehumidifier is concentrated in a packed bed regenerator by solar heated air. The strong solution is cooled by two heat exchangers before reentering the dehumidifier. Provisions to simulate conditions of high ambient humidity and temperature have been made. Experiments on the dehumidifier operating in a decoupled mode (without countercurrent regenerator operation) have been carried out. Cooling capacities in the range of 1.0--4.0 refrigeration tons have been achieved, depending upon the operating conditions. The effect of different independent variables on the capacity of the dehumidifier has been studied. An empirical equation correlating the variables have been obtained by statistical analysis of the data. The equation obtained indicates that the capacity of the dehumidifier depends strongly on the solution concentration, solution flow rate, air inlet temperature and the air humidity. Two other variables studied, the solution inlet temperature and the air flow rate, did not affect the cooling capacity greatly. The dependence of condensation rate on each of the variables is analyzed. 22 refs., 17 figs., 3 tabs.

Lenz, T.G.; Loef, G.O.G.; Patnaik, S.

1987-12-01T23:59:59.000Z

70

Energy saving controller for fluorescent lamps.  

E-Print Network (OSTI)

??Although fluorescent lamp is a very efficient lighting device in daily life, still the high harmonic distortion and low power factor cause unnecessary energy consumption. (more)

Cheong, Zhi Xiong

2010-01-01T23:59:59.000Z

71

Discharge lamp with reflective jacket  

DOE Patents (OSTI)

A discharge lamp includes an envelope, a fill which emits light when excited disposed in the envelope, a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed around the envelope and defining an opening, the reflector being configured to reflect some of the light emitted by the fill back into the fill while allowing some light to exit through the opening. The reflector may be made from a material having a similar thermal index of expansion as compared to the envelope and which is closely spaced to the envelope. The envelope material may be quartz and the reflector material may be either silica or alumina. The reflector may be formed as a jacket having a rigid structure which does not adhere to the envelope. The lamp may further include an optical clement spaced from the envelope and configured to reflect an unwanted component of light which exited the envelope back into the envelope through the opening in the reflector. Light which can be beneficially recaptured includes selected wavelength regions, a selected polarization, and selected angular components.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Kipling, Kent (Gaithersburg, MD)

2001-01-01T23:59:59.000Z

72

Development of a solar desiccant dehumidifier. Volume 1. Summary. Volume 2. Detailed technical information. Technical progress report  

DOE Green Energy (OSTI)

Research and development work aimed at the development of a solar desiccant dehumidifier is described in detail. The system features a rotary bed of granular silica gel and a rotary regenerator. The dehumidifier can be used for air conditioning through adiabatic saturation of the process airstream. Detailed technical information is presented in the appendices: (A) management, (B) review of the literature: state-of-the-art survey and SERI meeting, (C) review of the literature: adsorbent survey, (D) design requirements and evaluation criteria, (E) design requirements and evaluation criteria, single-family house model, (F) design requirements and evaluation criteria, economic model, (G) design requirements and evaluation criteria: conventional system models for comparison, (H) candidate cooling subsystems, (I) subsystem computer model, (J) subsystem performance map, and (K) subsystem preliminary design. (WHK)

Gunderson, M.E.; Hwang, K.C.; Railing, S.M.

1978-03-31T23:59:59.000Z

73

Portable lamp with dynamically controlled lighting distribution  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) arranged vertically with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum insures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2001-01-01T23:59:59.000Z

74

DuraLamp USA: Order (2010-CE-0912)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered DuraLamp USA, Inc. to pay a $2,500 civil penalty after finding DuraLamp USA had failed to certify that model PAR 30, an incandescent reflector lamp, complies with the applicable energy conservation standards.

75

Solid-state lamp with integral occupancy sensor  

E-Print Network (OSTI)

Previous work demonstrated a retrofit proximity detector for fluorescent lamps using the lamp's own stray electric fields. This paper extends the retrofit sensor system to a solid-state (LED) lamp. The design and implementation ...

Cooley, John J.

76

Driver Circuit for White LED Lamps with TRIAC Dimming Control.  

E-Print Network (OSTI)

??An efficient Light Emitting Diode (LED) lamp driver circuit is proposed for retrofitting the conventionally used incandescent lamps with existing TRIAC dimmer. The dimming feature (more)

Weng, Szu-Jung

2012-01-01T23:59:59.000Z

77

Compact Fluorescent Lamps : Technologies : From the Lab to the...  

NLE Websites -- All DOE Office Websites (Extended Search)

process. (Left) Compact Fluorescent Lamp; (Right) Cover of the 'Lighting Retrofit Workbook' (Left) Compact Fluorescent Lamp (CFL) (Right) Retrofitting national parks...

78

Lamp system for uniform semiconductor wafer heating  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

2001-01-01T23:59:59.000Z

79

LED lamp power management system and method  

DOE Patents (OSTI)

An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.

2013-03-19T23:59:59.000Z

80

Long-Term Performance of Screwbase Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

The packaging material for compact fluorescent lamps normally includes some claim regarding expected lamp lifetime. This claimed lifetime is generally not obtained through rigorous testing. This study shows how different operating cycles, components, and lamp and ballast designs affect screwbase compact fluorescent lamp (SCFL) life.

2000-04-11T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

High frequency inductive lamp and power oscillator  

DOE Patents (OSTI)

A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and/or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to match the driving frequency of the oscillator to a plurality of tuning states of the lamp.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Dolan, James T. (Frederick, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Leng, Yongzhang (Damascus, MD)

2000-01-01T23:59:59.000Z

82

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Torchieres Torchieres Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of torchieres since 2005. A torchiere, or torch lamp, is a lamp fixture with a tall (such as 5 foot) stand of wood or metal. Torchiere lamps use fluorescent or halogen incandescent light bulbs. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates There are no recent updates for this product. Standards for Torchieres The following content summarizes the energy conservation standards of DOE's regulations. The text is not an official reproduction of the Code of Federal Regulations and should not be used for legal research or citation.

83

Building Technologies Office: Fluorescent and Incandescent Lamps Public  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent and Fluorescent and Incandescent Lamps Public Meeting to someone by E-mail Share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Facebook Tweet about Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Twitter Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Google Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Delicious Rank Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Digg Find More places to share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on AddThis.com... About Standards & Test Procedures Implementation, Certification & Enforcement

84

Assessing Consumer Values and the Supply-Chain Market for the Integrated Water Heater/Dehumidifier  

SciTech Connect

This paper presents a case study of the potential market for the dual-service residential integrated water heater/dehumidifier (WHD). Its principal purpose is to evaluate the extent to which this integrated appliance might penetrate the residential market sector, given current market trends, producer and consumer attributes, and technical parameters. The report's secondary purpose is to gather background information leading to a generic framework for conducting market analyses of technologies. This framework can be used to assess market readiness as well as factor preferred product attributes into the design to drive consumer demand for this product. This study also supports analysis for prototype design. A full market analysis for potential commercialization should be conducted after prototype development. The integrated WHD is essentially a heat-pump water heater (HPWH) with components and controls that allow dedicated dehumidification. Adequate residential humidity control is a growing issue for newly constructed residential homes, which are insulated so well that mechanical ventilation may be necessary to meet fresh air requirements. Leveraging its successful experience with the energy-efficient design improvement for the residential HPWH, the Oak Ridge National Laboratory's (ORNL's) Engineering Science and Technology Division's (ESTD's) Building Equipment Group designed a water-heating appliance that combines HPWH efficiency with dedicated dehumidification. This integrated appliance could be a low-cost solution for dehumidification and efficient electric water heating. ORNL is partnering with Western Carolina University, Asheville-Buncombe Technical Community College, American Carolina Stamping Company, and Clemson University to develop this appliance and assess its market potential. For practical purposes, consumers are indifferent to how water is heated but are very interested in product attributes such as initial first cost, operating cost, performance, serviceability, product size, and installation costs. The principal drivers for penetrating markets are demonstrating reliability, leveraging the dehumidification attributes of the integrated WHD, and creating programs that embrace first-cost and life-cycle cost principles.

Ashdown, BG

2005-01-11T23:59:59.000Z

85

Max Tech and Beyond: Fluorescent Lamps  

Science Conference Proceedings (OSTI)

Fluorescent lamps are the most widely used artificial light source today, responsible for approximately 70% of the lumens delivered to our living spaces globally. The technology was originally commercialized in the 1930's, and manufacturers have been steadily improving the efficacy of these lamps over the years through modifications to the phosphors, cathodes, fill-gas, operating frequency, tube diameter and other design attributes. The most efficient commercially available fluorescent lamp is the 25 Watt T5 lamp. This lamp operates at 114-116 lumens per watt while also providing good color rendering and more than 20,000 hours of operating life. Industry experts interviewed indicated that while this lamp is the most efficient in the market today, there is still a further 10 to 14% of potential improvements that may be introduced to the market over the next 2 to 5 years. These improvements include further developments in phosphors, fill-gas, cathode coatings and ultraviolet (UV) reflective glass coatings. The commercialization of these technology improvements will combine to bring about efficacy improvements that will push the technology up to a maximum 125 to 130 lumens per watt. One critical issue raised by researchers that may present a barrier to the realization of these improvements is the fact that technology investment in fluorescent lamps is being reduced in order to prioritize research into light emitting diodes (LEDs) and ceramic metal halide high intensity discharge (HID) lamps. Thus, it is uncertain whether these potential efficacy improvements will be developed, patented and commercialized. The emphasis for premium efficacy will continue to focus on T5 lamps, which are expected to continue to be marketed along with the T8 lamp. Industry experts highlighted the fact that an advantage of the T5 lamp is the fact that it is 40% smaller and yet provides an equivalent lumen output to that of a T8 or T12 lamp. Due to its smaller form factor, the T5 lamp contains less material (i.e., glass, fill gas and phosphor), and has a higher luminance, enabling fixtures to take advantage of the smaller lamp size to improve the optics and provide more efficient overall system illuminance. In addition to offering the market a high-quality efficacious light source, another strong value proposition of fluorescent lighting is its long operating life. In today's market, one manufacturer is offering fluorescent lamps that have a rated life of 79,000 hours - which represents 18 years of service at 12 hours per day, 365 days per year. These lamps, operated using a long-life ballast specified by the manufacturer, take advantage of improvements in cathode coatings, fill gas chemistry and pressure to extend service life by a factor of four over conventional fluorescent lamps. It should be noted that this service life is also longer (approximately twice as long) as today's high-quality LED products. The fluorescent market is currently focused on the T5 and T8 lamp diameters, and it is not expected that other diameters would be introduced. Although T8 is a more optimal diameter from an efficacy perspective, the premium efficiency and optimization effort has been focused on T5 lamps because they are 40% smaller than T8, and are designed to operate at a higher temperature using high-frequency electronic ballasts. The T5 lamp offers savings in terms of materials, packaging and shipping, as well as smaller fixtures with improved optical performance. Manufacturers are actively researching improvements in four critical areas that are expected to yield additional efficacy improvements of approximately 10 to 14 percent over the next five years, ultimately achieving approximately 130 lumens per watt by 2015. The active areas of research where these improvements are anticipated include: (1) Improved phosphors which continue to be developed and patented, enabling higher efficacies as well as better color rendering and lumen maintenance; (2) Enhanced fill gas - adjusting proportions of argon, krypton, neon and xenon to optimize performance, while also m

Scholand, Michael

2012-04-01T23:59:59.000Z

86

High frequency inductive lamp and power oscillator  

DOE Patents (OSTI)

A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and I or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to adjust the driving frequency of the oscillator.

MacLennan, Donald A. (Gaithersburg, MD); Dymond, Jr., Lauren E. (North Potomac, MD); Gitsevich, Aleksandr (Montgomery Village, MD); Grimm, William G. (Silver Spring, MD); Kipling, Kent (Gaithersburg, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Ola, Samuel A. (Silver Spring, MD); Simpson, James E. (Gaithersburg, MD); Trimble, William C. (Columbia, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

2001-01-01T23:59:59.000Z

87

Energy Cost Calculator for Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Compact Fluorescent Lamps Compact Fluorescent Lamps Energy Cost Calculator for Compact Fluorescent Lamps October 8, 2013 - 2:18pm Addthis This tool calculates the payback period for your calc retrofit project. Modify the default values to suit your project requirements. Existing incandescent lamp wattage Watts Incandescent lamp cost dollars Incandescent lamp life 1000 hours calc wattage Watts calc cost dollars calc life (6000 hours for moderate use, 10000 hours for high use) 8000 hours Number of lamps in retrofit project Hours operating per week hours Average cost of electricity 0.06 $/kWh Relamper labor costs $/hr Time taken to retrofit all lamps in this project min Time taken to relamp one lamp min Type of Relamping Practiced: Group Relamping: Calculate Simple Payback Period months

88

Assessing Consumer Values and the Supply-Chain Market for the Integrated Water Heater/Dehumidifier  

SciTech Connect

This paper presents a case study of the potential market for the dual-service residential integrated water heater/dehumidifier (WHD). Its principal purpose is to evaluate the extent to which this integrated appliance might penetrate the residential market sector, given current market trends, producer and consumer attributes, and technical parameters. The report's secondary purpose is to gather background information leading to a generic framework for conducting market analyses of technologies. This framework can be used to assess market readiness as well as factor preferred product attributes into the design to drive consumer demand for this product. This study also supports analysis for prototype design. A full market analysis for potential commercialization should be conducted after prototype development. The integrated WHD is essentially a heat-pump water heater (HPWH) with components and controls that allow dedicated dehumidification. Adequate residential humidity control is a growing issue for newly constructed residential homes, which are insulated so well that mechanical ventilation may be necessary to meet fresh air requirements. Leveraging its successful experience with the energy-efficient design improvement for the residential HPWH, the Oak Ridge National Laboratory's (ORNL's) Engineering Science and Technology Division's (ESTD's) Building Equipment Group designed a water-heating appliance that combines HPWH efficiency with dedicated dehumidification. This integrated appliance could be a low-cost solution for dehumidification and efficient electric water heating. ORNL is partnering with Western Carolina University, Asheville-Buncombe Technical Community College, American Carolina Stamping Company, and Clemson University to develop this appliance and assess its market potential. For practical purposes, consumers are indifferent to how water is heated but are very interested in product attributes such as initial first cost, operating cost, performance, serviceability, product size, and installation costs. The principal drivers for penetrating markets are demonstrating reliability, leveraging the dehumidification attributes of the integrated WHD, and creating programs that embrace first-cost and life-cycle cost principles.

Ashdown, BG

2005-01-11T23:59:59.000Z

89

Survivability of Electronic Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This EPRI Technical Report addresses the fastest growing energy efficient light source8212the electronic compact fluorescent lamp (CFL). Because some of the failure modes for screw-in CFLs are different than those for plug-in CFLs, a cursory review of the difference between the two types of CFLs is provided in the first part of Chapter 2. A broad definition of shortened-life CFLs is also provided in Chapter 2 with an emphasis on revisiting mortality curves, the 10-minute lamp start, other relevant defini...

2008-03-31T23:59:59.000Z

90

Energy Performance of Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents the results of tests performed at the Worcester Polytechnic Institute, in contract with the EPRI Power Electronics Applications Center (PEAC), to determine the light output, power consumption, efficiency, and power factor of off-the-shelf electronic and magnetic compact fluorescent lamps.

2003-12-31T23:59:59.000Z

91

Laboratory Evaluation of LED T8 Replacement Lamp Products  

Science Conference Proceedings (OSTI)

A report on a lab setting analysis involving LED lamps intended to directly replace T8 fluorescent lamps (4') showing light output, power, and economic comparisons with other fluorescent options.

Richman, Eric E.; Kinzey, Bruce R.; Miller, Naomi J.

2011-05-23T23:59:59.000Z

92

The Effects of Table Lamp Shade Shape and Compact Fluorescent...  

NLE Websites -- All DOE Office Websites (Extended Search)

The Effects of Table Lamp Shade Shape and Compact Fluorescent Lamp Burning Position on Visual Comfort Speaker(s): Zaidi Abdullah Date: March 15, 2001 - 12:00pm Location: Bldg. 90...

93

Light Flicker in Compact Fluorescent Lamps Caused by Voltage Fluctuations  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the EPRI Power Electronics Applications Center (PEAC) Power Quality Test Facility to characterize the light output of an incandescent lamp and compact fluorescent lamps during voltage fluctuations.

2003-12-31T23:59:59.000Z

94

Improving Comfort in Hot-Humid Climates with a Whole-House Dehumidifier, Windermere, Florida (Fact Sheet)  

SciTech Connect

Maintaining comfort in a home can be challenging in hot-humid climates. At the common summer temperature set point of 75 degrees F, the perceived air temperature can vary by 11 degrees F because higher indoor humidity reduces comfort. Often the air conditioner (AC) thermostat set point is lower than the desirable cooling level to try to increase moisture removal so that the interior air is not humid or "muggy." However, this method is not always effective in maintaining indoor relative humidity (RH) or comfort. In order to quantify the performance of a combined whole-house dehumidifier (WHD) AC system, researchers from the U.S. Department of Energy's Building America team Consortium of Advanced Residential Buildings (CARB) monitored the operation of two Lennox AC systems coupled with a Honeywell DH150 TrueDRY whole-house dehumidifier for a six-month period. By using a WHD to control moisture levels (latent cooling) and optimizing a central AC to control temperature (sensible cooling), improvements in comfort can be achieved while reducing utility costs. Indoor comfort for this study was defined as maintaining indoor conditions at below 60% RH and a humidity ratio of 0.012 lbm/lbm while at common dry bulb set point temperatures of 74 degrees -80 degrees F. In addition to enhanced comfort, controlling moisture to these levels can reduce the risk of other potential issues such as mold growth, pests, and building component degradation. Because a standard AC must also reduce dry bulb air temperature in order to remove moisture, a WHD is typically needed to support these latent loads when sensible heat removal is not desired.

Not Available

2013-11-01T23:59:59.000Z

95

Novel Nanophosphors for High Efficiency Fluorescent Lamps  

SciTech Connect

This is the Final Report of the Novel Nanophosphors for High Efficiency Fluorescent Lamps, Department of Energy (DOE). The overall goal of this three-year program is to develop novel hybrid phosphors by coating commercially available lamp phosphors with highly stable wide band-gap nanocrystalline phosphors (NCP). The prime technical approach is the development of NCP quantum-splitting phosphor (QSP) and ultra-violet (UV) emitting phosphors with quantum efficiencies exceeding that of the conventional phosphors at 185 nm. The novel hybrid phosphors will increase the efficiency of the fluorescent lamps by up to 32%, enabling total energy savings of 0.26 quads, the reduction in the U.S. energy bill by $6.5 billion and the reduction of the annual carbon emission by 4.1 billion kilogram. Our work started by investigating through modeling calculations the requirement for the particle size of the NCP. Our work to develop suitable nanocrystalline phosphors started with the known oxide quantum splitting and UV emitting phosphors. We demonstrated several synthesis techniques for the production of high quality nanocrystalline materials that crystallizes in the desired phase and with the desired particle size. In collaboration with our subcontractor we demonstrated the feasibility for the manufacture of NC phosphors. We also demonstrated novel techniques of coating the NCP on the surface of micron sized phosphors. Our chief achievement pertains to the successful testing of the coated hybrid phosphor systems in linear fluorescent lamps. In linear fluorescent lamp tests, we have demonstrated up to 7% increase in the efficacy of hybrid phosphors over the conventional (uncoated) phosphors. We have also demonstrated the improvement in the lumen maintenance of the coated phosphors. A hybrid phosphor system based on the commercial red emitting phosphor, Y{sub 2}O{sub 3}:Eu{sup 3+} did not show the anticipated improvement in lamp efficacy. We explored the reasons for this observation, which are detailed in this report. Within the program we have carried out fundamental investigations into the physical processes that determine the quantum splitting behavior of the Pr{sup 3+} ion in solids. Specifically, we have investigated the quantum splitting luminescence of this ion in the LaPO{sub 4}, SrAl{sub 12}O{sub 19} and LiLaP{sub 4}O{sub 12} host lattices. In this final report we summarize the technical work completed under the Program, summarize our findings about the performance limits of the various technologies we investigated, and outline promising paths for future work.

Alok Srivatava

2007-03-31T23:59:59.000Z

96

Controlling the vapor pressure of a mercury lamp  

DOE Patents (OSTI)

The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled.

Grossman, Mark W. (Belmont, MA); George, William A. (Rockport, MA)

1988-01-01T23:59:59.000Z

97

Controlling the vapor pressure of a mercury lamp  

DOE Patents (OSTI)

The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled. 2 figs.

Grossman, M.W.; George, W.A.

1988-05-24T23:59:59.000Z

98

LED lamp color control system and method  

DOE Patents (OSTI)

An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A.M.

2013-02-05T23:59:59.000Z

99

Lighting Group: Sources and Ballasts: LED Reflector Lamp  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Reflector Lamp LED Reflector Lamp LED Reflector Lamp Objective LED reflector lamp The goal of this project is to develop a revolutionary new reflector lamp which offers many advantages over current incandescent reflector lamps, including: three times greater efficiency ten times the rated life greater optical and performance properties use of light emitting diodes (LEDs) to generate the light. Although LEDs have been commercially available since the late 1960’s, recent dramatic improvements in LED technology have led to white light devices with efficiencies that meet or exceed those of a standard incandescent lamp. This project will build upon these improvements to develop a new type of source for focusing light. Contact Information For more information on this project, please contact:

100

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible is disclosed. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture. 20 figs.

MacLennan, D.A.; Turner, B.; Kipling, K.

1999-05-11T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture.

MacLennan, Donald A. (Butler, PA); Turner, Brian (Damascus, MD); Kipling, Kent (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

102

High output lamp with high brightness  

DOE Patents (OSTI)

An ultra bright, low wattage inductively coupled electrodeless aperture lamp is powered by a solid state RF source in the range of several tens to several hundreds of watts at various frequencies in the range of 400 to 900 MHz. Numerous novel lamp circuits and components are disclosed including a wedding ring shaped coil having one axial and one radial lead, a high accuracy capacitor stack, a high thermal conductivity aperture cup and various other aperture bulb configurations, a coaxial capacitor arrangement, and an integrated coil and capacitor assembly. Numerous novel RF circuits are also disclosed including a high power oscillator circuit with reduced complexity resonant pole configuration, parallel RF power FET transistors with soft gate switching, a continuously variable frequency tuning circuit, a six port directional coupler, an impedance switching RF source, and an RF source with controlled frequency-load characteristics. Numerous novel RF control methods are disclosed including controlled adjustment of the operating frequency to find a resonant frequency and reduce reflected RF power, controlled switching of an impedance switched lamp system, active power control and active gate bias control.

Kirkpatrick, Douglas A. (Great Falls, VA); Bass, Gary K. (Mt. Airy, MD); Copsey, Jesse F. (Germantown, MD); Garber, Jr., William E. (Poolesville, MD); Kwong, Vincent H. (Vancouver, CA); Levin, Izrail (Silver Spring, MD); MacLennan, Donald A. (Gaithersburg, MD); Roy, Robert J. (Frederick, MD); Steiner, Paul E. (Olney, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

2002-01-01T23:59:59.000Z

103

High intensity discharge lamp self-adjusting ballast system sensitive to the radiant energy or heat of the lamp  

SciTech Connect

This patent describes a self-adjusting ballast system for mercury vapor, high intensity discharge lamps having outputs of 100 watts or greater, comprising: a direct current source; a lamp circuit containing a high intensity discharge lamp; sensing means for sensing the radiant energy output of the lamp; a pulse width modulator which, in response to the output of the sensing means, varies the width of the pulses that power the lamp during warm-up of the lamp; a high frequency oscillator; a DC to AC converter that converts current from the direct source to pulses of alternating current for powering the lamp, the converter comprising: at least one switch for gating current to the lamp; a switch control means, responsive to the high frequency oscillator, for controlling the switch and controlling the frequency of the alternating current pulses that power the lamp; current sensing means for sensing the current being supplied to the lamp; and current control means for limiting the current through the lamp to a predetermined safe level when the current sensed by the current sensing means exceeds a reference value.

Kuhnel, D.S.; Ottenstein, S.A.

1987-07-21T23:59:59.000Z

104

Photometric assessment of energy efficient torchieres  

E-Print Network (OSTI)

and Renewable Energy, Office of Building Technology, State andand Renewable Energy, Office of Building Technology, State and

Page, Erik; Siminovitch, Michael

1997-01-01T23:59:59.000Z

105

Open cycle liquid desiccant dehumidifier and hybrid solar/electric absorption refrigeration system. Annual report, January 1993--December 1993. Calendar year 1993  

DOE Green Energy (OSTI)

This annual report presents work performed during calendar year 1993 by the Florida Solar Energy Center under contract to the US Department of Energy. Two distinctively different solar powered indoor climate control systems were analyzed: the open cycle liquid desiccant dehumidifier, and an improved efficiency absorption system which may be fired by flat plate solar collectors. Both tasks represent new directions relative to prior FSEC research in Solar Cooling and Dehumidification.

Nimmo, B.G.; Thornbloom, M.D.

1995-04-01T23:59:59.000Z

106

Hybrid electronic ballast operating the HPS lamp at constant power  

SciTech Connect

A hybrid solid-state ballast that operates high-pressure sodium (HPS) lamps at main frequency with constant power through rated life is described. The system utilizes two inductors connected in series and a bidirectional semiconductor switch connected in parallel to one of them. A lamp-starting circuit has also been included in the ballast. The static switch, with phase angle control provided by power feedback, actuates on lamp current compensating variations of the main voltage and increases of lamp arc voltage. The system offers the following: (1) increase of lamp life and system lumen maintenance; (2) power factor and total harmonic distortion of line current comparable to conventional lag ballast; and (3) operating cost savings, both in terms of energy cost and lamp replacement cost.

Kaiser, W. [Univ. de Sao Paulo (Brazil)

1998-03-01T23:59:59.000Z

107

Compact microwave lamp having a tuning block and a dielectric located in a lamp cavity  

DOE Patents (OSTI)

A microwave lamp having a compact structure utilizing a coupling slot which has a dielectric member extending therethrough and a tuning block adjoining the coupling slot. A non-conventional waveguide is used which has about the width of a WR-284 waveguide and about the length of a WR-340 waveguide.

Simpson, James E. (Gaithersburg, MD)

2000-01-01T23:59:59.000Z

108

LED LAMP OR BULB WITH REMOTE PHOSPHOR AND DIFFUSER ...  

An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and an optical cavity. The optical cavity comprises a phosphor ...

109

Heat transfer assembly for a fluorescent lamp and fixture  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.

Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.

1992-12-29T23:59:59.000Z

110

Fluorescent lamp unit with magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp unit having a magnetic field generating means for improving the performance of the fluorescent lamp is disclosed. In a preferred embodiment the fluorescent lamp comprises four longitudinally extending leg portions disposed in substantially quadrangular columnar array and joined by three generally U-shaped portions disposed in different planes. In another embodiment of the invention the magnetic field generating means comprises a plurality of permanent magnets secured together to form a single columnar structure disposed within a centrally located region defined by the shape of lamp envelope. 4 figs.

Grossman, M.W.; George, W.A.

1989-08-08T23:59:59.000Z

111

Development and characterization of a high CRI LED lamp.  

E-Print Network (OSTI)

??The aim of this thesis is to realize a high CRI LED lamp using the color mixing technique. We start from a high efficiency white (more)

Meneghesso , Matteo

2012-01-01T23:59:59.000Z

112

Stadiums and arenas use efficient, high wattage lamps - Today ...  

U.S. Energy Information Administration (EIA)

Other lighting types, such as light-emitting diode (LED), incandescent, and halogen lamps, are used in applications like signals, signage, ...

113

Heat transfer assembly for a fluorescent lamp and fixture  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure.

Siminovitch, Michael J. (Richmond, CA); Rubenstein, Francis M. (Berkeley, CA); Whitman, Richard E. (Richmond, CA)

1992-01-01T23:59:59.000Z

114

Fluorescent lamp with static magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed.

Moskowitz, Philip E. (Peabody, MA); Maya, Jakob (Brookline, MA)

1987-01-01T23:59:59.000Z

115

Fluorescent lamp with static magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed. 2 figs.

Moskowitz, P.E.; Maya, J.

1987-09-08T23:59:59.000Z

116

Convection venting lensed reflector-type compact fluorescent lamp system  

DOE Patents (OSTI)

Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures. 12 figs.

Pelton, B.A.; Siminovitch, M.

1997-07-29T23:59:59.000Z

117

An Electrical Cathode Model of a High Pressure Sodium Lamp  

Science Conference Proceedings (OSTI)

An electrical cathode model (ECM) of a high pressure sodium lamp (HPS) based on physical laws has been developed. The proposed ECM calculates the instantaneous voltage drop in a cathode sheath and the temperature distribution inside the cathode using ... Keywords: cathode model, HPS lamp ballast designs

Jose Luis Tapia; Joel O. Pacheco Sotelo; Eduardo Diaz Rodriguez; Yulia Nikolaevna Ledeneva; Rene Arnulfo Garcia Hernandez

2010-09-01T23:59:59.000Z

118

Convection venting lensed reflector-type compact fluorescent lamp system  

SciTech Connect

Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures.

Pelton, Bruce A. (825 Manor Rd., El Sobrante, CA 94803); Siminovitch, Michael (829 Manor Rd., El Sobrante, CA 94803)

1997-01-01T23:59:59.000Z

119

DEFINING THE EFFECTIVENESS OF UV LAMPS  

Office of Scientific and Technical Information (OSTI)

ARTI-21CR/610-40030-01 ARTI-21CR/610-40030-01 DEFINING THE EFFECTIVENESS OF UV LAMPS INSTALLED IN CIRCULATING AIR DUCTWORK Final Report Date Published - November 2002 Douglas VanOsdell and Karin Foarde RTI P.O. Box 12194 Research Triangle Park, NC 27709-2194 Prepared for the AIR-CONDITIONING AND REFRIGERATION TECHNOLOGY INSTITUTE 4100 N. Fairfax Drive, Suite 200, Arlington, Virginia 22203 Distribution A - Approved for public release; further dissemination unlimited. DISCLAIMER This report was prepared as an account of work sponsored by the Air-Conditioning and Refrigeration Technology Institute (ARTI) under its "HVAC&R Research for the 21 st Century" (21-CR) program. Neither ARTI, the financial supporters of the 21-CR program, or any agency

120

Contrast between the vertical and horizontal mercury discharge lamps  

SciTech Connect

This paper discusses the thermal behavior of a high pressure mercury lamp in a horizontal position, compared with that of a vertical lamp. The model adopted is three-dimensional, steady, and powered DC. After the model validation, we analyzed temperature fields and velocities for the case of the lamp in a horizontal position by comparing it with those of a lamp in vertical position. This setting initially fixed the wall temperature equal to 1000 K. However, the morphology of the temperature profile in the case of the horizontal lamp indicates that the temperature of the wall cannot be uniform. Thus, we have, in a second time, performed an energy balance at the wall to calculate its temperature. This aims to understand the influence of convection on the thermal properties of the source.

Ben Hamida, M. B.; Helali, H.; Araoud, Z.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

2011-06-15T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Effect of filament power removal on a fluorescent lamp system  

SciTech Connect

Two techniques are used to measure the effects of removing the filament power from a two-lamp, F-40, rapid-start fluorescent lamp system. The changes are measured for a standard CBM core-coil ballast and for a solid-state ballast operating the lamp at high frequency. There is a 4 tp 6% increase in system efficacy when the filament power is removed. Removal of filament power also decreases filament temperature from 1000/sup 0/C to below 700/sup 0/C in lamps operated at 60 Hz, and from above 600/sup 0/C to 300/sup 0/C in lamps operated at high frequency. The study shows that the arc current and anode fall also determine filament temperature.

Verderber, R.R.; Morse, O.; Rubinstein, F.M.

1985-07-01T23:59:59.000Z

122

Compatibility testing of fluorescent lamp and ballast systems  

SciTech Connect

The rapid growth in the use of electronic ballasts for fluorescent lighting systems, and the corresponding increase in the number of new products and new manufacturers in the market, has raised a number of questions regarding the compatibility of the lamps and ballasts used in fluorescent systems. Because many of the new products start and operate lamps differently than previous products, the relevant American National Standards Institute requirements may no longer be adequate for addressing compatibility concerns. The impacts on system performance of the newer products of a parametric study designed to test key hypotheses regarding the impact of ballast parameters on fluorescent lamp life. In this study, samples of 4-ft T8 fluorescent lamps were operated on duty cycles of 5 min on and 5 min off, using seven different ballast types. The results of the study indicate which parameters seem to have the biggest effect on lamp life, and can be used in establishing new performance standards for fluorescent systems.

Ji, Y.; Davis, R.; O' Rourke, C.; Chui, E.W.M.

1999-12-01T23:59:59.000Z

123

The effects of fixture type and HVAC integration on fluorescent lamp/ballast performance  

SciTech Connect

This paper describes the effects of fixture type and lamp compartment air extract characteristics on lamp/ballast performance. A luminaire/plenum/HVAC simulator was used to measure minimum lamp wall temperature inside four fixture types while varying lamp-compartment extract conditions. Experimental data show that the lumen output of the lamp/ballast system varies by 20% and system efficacy by 10%, depending on the type of fixture and lamp-compartment extract technique employed.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.; Clark, T.A.

1986-06-01T23:59:59.000Z

124

Max Tech and Beyond: High-Intensity Discharge Lamps  

Science Conference Proceedings (OSTI)

High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable operating conditions, and this necessitates additional power beyond that used by the lamp itself. HID lamps offer important advantages compared to other lighting technologies, making them well suited for certain applications. HID lamps can be very efficient, have long operating lives, are relatively temperature-insensitive and produce a large quantity of light from a small package. For these reasons, HID lamps are often used when high levels of illumination are required over large areas and where operating and maintenance costs must be kept to a minimum. Furthermore, if the installation has a significant mounting height, high-power HID lamps can offer superior optical performance luminaires, reducing the number of lamps required to illuminate a given area. The indoor environments best suited to HID lamps are those with high ceilings, such as those commonly found in industrial spaces, warehouses, large retail spaces, sports halls and large public areas. Research into efficacy improvements for HID lighting technologies has generally followed market demand for these lamps, which is in decline for MV and LPS, has reached a plateau for HPS and is growing for MH. Several manufacturers interviewed for this study indicated that although solid-state lighting was now receiving the bulk of their company's R&D investment, there are still strong HID lamp research programs, which concentrate on MH technologies, with some limited amount of investment in HPS for specific niche applications (e.g., agricultural greenhouses). LPS and MV lamps are no longer being researched or improved in terms of efficacy or other performance attributes, although some consider MH HID lamps to be the next-generation MV lamp. Thus, the efficacy values of commercially available MV, LPS and HPS lamps are not expected to increase in the next 5 to 10 years. MH lamps, and more specifically, ceramic MH lamps are continuing to improve in efficacy as well as light quality, manufacturability and lamp life. Within an HID lamp, the light-producing plasma must be heated to sufficiently high temperatures to achieve high efficiencie

Scholand, Michael

2012-04-01T23:59:59.000Z

125

Highly Efficient Small Form Factor LED Retrofit Lamp  

SciTech Connect

This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent power quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40{sup o} and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.

Steven Allen; Fred Palmer; Ming Li

2011-09-11T23:59:59.000Z

126

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

An electrodeless microwave discharge lamp includes an envelope with a discharge forming fill disposed therein which emits light, the fill being capable of absorbing light at one wavelength and re-emitting the absorbed light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill, a source of microwave energy coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed within the microwave cavity and configured to reflect at least some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD)

2001-01-01T23:59:59.000Z

127

Covered Product Category: Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps October 7, 2013 - 10:48am Addthis ENERGY STAR Qualified Products Federal Energy Management Program (FEMP) provides acquisition guidance across a variety of product categories, including compact fluorescent lamps (CFLs), which are an ENERGY STAR-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR.

128

Information Resources: LED Replacements for Linear Fluorescent Lamps  

NLE Websites -- All DOE Office Websites (Extended Search)

Replacements for Linear Fluorescent Lamps Webcast Replacements for Linear Fluorescent Lamps Webcast In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting Facts-listed products as well as products evaluated in the latest CALiPER reports. Eric Richman, also of PNNL, reported on a recently completed GATEWAY demonstration project, in which LED and fluorescent lamps were installed in a variety of recessed troffer luminaires for comparison in an office environment. The presentation concluded with a discussion of specifications listed in a newly updated technology fact sheet. View presentation slides View the text-alternative version View the webcast (WMV 16 MB) Download Windows Media Player

129

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

the reason industry started by developing ceramic MH lampsceramic metal halide lamps, which are the focus of industryindustry had invested in the development of very low wattage ceramic

Scholand, Michael

2012-01-01T23:59:59.000Z

130

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

button, a 100 watt (130 volt) lamp, a 100 watt long lifeFluorescent Watt L I ltage (volts) cu ge ic in s) ative ( 1the diode energy button (83 volts) was obtained by dividing

Verderber, Rudy

2013-01-01T23:59:59.000Z

131

The LAMP QPF Products. Part I: Model Development  

Science Conference Proceedings (OSTI)

The Local AWIPS (Advanced Weather Interactive Processing System) MOS (model output statistics) Program (LAMP) quantitative precipitation forecast (QPF) system produces 122-h forecasts of precipitation over the conterminous United States. The ...

Jerome P. Charba

1998-12-01T23:59:59.000Z

132

One piece microwave container screens for electrodeless lamps  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. Replacing mesh material by solid metal material as part of the screen unit significantly reduces leakage of microwave energy from the lamp. The solid section has multiple compliant fingers defined therein for engaging the periphery of a flange on the waveguide unit so that a hose clamp can easily secure the screen to the assembly. Screen units of this type having different mesh section configurations can be interchanged in the lamp assembly to produce different respective illumination patterns.

Turner, Brian (Myersville, MD); Ury, Michael (Bethesda, MD)

1998-01-01T23:59:59.000Z

133

Electronic Radio-Frequency (Electrodeless) Induction Lamps: A Fluorescent Technology  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses an expanding energy efficient light source electronic radio-frequency (electrodeless) induction lamps. Business and technical market factors (Chapter 2) use the past and future growth of the CFL market to illustrate the potential for the induction lighting market while emphasizing future technical improvements. Discussion of the importance of utility involvement in helping their customers consider induction lamps for high-efficiency fluorescent applications with long-...

2007-12-20T23:59:59.000Z

134

An ultraviolet barrier-discharge OH molecular lamp  

Science Conference Proceedings (OSTI)

The energy and spectral parameters of a barrier discharge in a mixture of argon with hydroxyl {sup .}OH are studied experimentally. A sealed lamp with the radiation intensity maximum at {lambda} = 309.2 nm, an emitting surface area of {approx}700 cm{sup 2}, and a radiant excitance of 1.5 mW cm{sup -2} has been fabricated. The radiant power of the lamp is 1.1 W. (laser applications and other topics in quantum electronics)

Sosnin, E A; Erofeev, M V; Avdeev, S M; Panchenko, Aleksei N; Panarin, V A; Skakun, V S; Tarasenko, Viktor F; Shitts, D V [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

2006-10-31T23:59:59.000Z

135

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

DOE Patents (OSTI)

A novel design is described for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment. 9 figs.

Siminovitch, M.

1998-02-10T23:59:59.000Z

136

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

SciTech Connect

A novel design for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment.

Siminovitch, Michael (El Sobrante, CA)

1998-01-01T23:59:59.000Z

137

Studies on Temperature Dependence of Rubidium Lamp for Atomic Frequency Standard  

Science Conference Proceedings (OSTI)

Rb lamp is a very critical component of the Rb atomic clock's Physics Package. The Rb lamp's performance is very sensitive to temperature and its stability. In this paper we discuss the behaviors of Rb Lamp with temperature. The Rb lamp exciter power and temperature of Rb bulb are very important parameters in controlling the performance of the Rb Lamp. It is observed that at temperatures beyond 110 deg. C, the lamp mode changes from the ring to red mode resulting in abnormal broadening of emission lines and self reversal. The results of our studies on spectral analysis of Rb lamp under various operating conditions are reported in the paper.

Ghosal, Bikash; Banik, Alak; Vats, Vaibhav; Pal, Sukamal; Bahl, R. K [Space Applications Centre, ISRO, Ahmedabad-380015 (India)

2011-10-20T23:59:59.000Z

138

Dehumidifiers | Open Energy Information  

Open Energy Info (EERE)

source History View New Pages Recent Changes All Special Pages Semantic SearchQuerying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook...

139

Very high efficacy electrodeless high intensity discharge lamps  

DOE Patents (OSTI)

An electrodeless arc lamp comprises an outer jacket hermetically sealing and thermally protecting an arc tube inside which has an upwardly convex bottom center section. The absence of chemically reactive electrode material makes it possible to use metal halides other than iodides. The tube contains chlorides, bromides or a mixture thereof of scandium and sodium in a nearly equimolar relationship in addition to mercury and an inert gas. Good color balance can be obtained at reduced reservoir temperature and with less power loss. Reduction in wall temperature makes it possible to attain longer lamp life.

Johnson, P.D.

1985-10-03T23:59:59.000Z

140

New LED light sources and lamps for general illumination  

E-Print Network (OSTI)

of light source compared to traditional light sources like incandescent bulbs and fluorescent tubes bulb. LEDs emit colored light with a narrow spectral band of 20-30 nm, colors covering the spectralNew LED light sources and lamps for general illumination Carsten Dam-Hansen, Birgitte Thestrup

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry  

NLE Websites -- All DOE Office Websites (Extended Search)

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry Speaker(s): Francis Rubinstein Date: February 14, 2008 - 12:00pm Location: 90-3122 Fluorescent lamp ballasts are subject to DOE appliance standards and rulemaking. But currently, only ballasts for older fluorescent lamp types, such as T-12 lamps are subject to minimum efficacy limits. The majority of fluorescent lamps now being shipped (T-8 and T-5 types) type are operated by ballasts that will not be subject to DOE rule until 2011. The metric used by DOE for characterizing the electrical efficiency of the fluorescent lamp-ballast system is called Ballast Efficacy Factor (BEF). Because BEF is not normalized, it is of limited utility for rulemaking and is useless for procurement. But by normalizing BEF to the total lamp power, I have

142

Solid-State Lighting: LED Replacement Lamps: Current Performance and the  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Replacement Lamps: Current LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® to someone by E-mail Share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Facebook Tweet about Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Twitter Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Google Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Delicious Rank Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Digg Find More places to share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on

143

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

E-Print Network (OSTI)

the economics of fuel-based and LED lighting technology fordata logger equipped rechargeable LED lamps, monitoring theadoption of the LED lamps, and a follow-up survey. 1 Figure

Johnstone, Peter

2009-01-01T23:59:59.000Z

144

Information on the Fate of Mercury From Fluorescent Lamps Disposed in Landfills  

Science Conference Proceedings (OSTI)

Mercury is contained in energy-efficient fluorescent, mercury-vapor, metal halide, and high-pressure sodium lamps. This report presents information on the potential for air and groundwater contamination when mercury lamps are disposed in municipal landfills.

1995-04-19T23:59:59.000Z

145

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and  

E-Print Network (OSTI)

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium light tubes are recycled. They are made from aluminum and metal. Aluminum is a silver-white metal and is very light in weight and strong. Because aluminum is ductile, it can be drawn into wires or pressed

Ungerleider, Leslie G.

146

Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface.

Siminovitch, Michael J. (Richmond, CA)

1992-01-01T23:59:59.000Z

147

Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface. 12 figs.

Siminovitch, M.J.

1992-11-10T23:59:59.000Z

148

Inrush related problems caused by lamps with electronic drivers and their mitigation  

Science Conference Proceedings (OSTI)

New types of appliances sometimes bring unexpected power quality problems. On several locations it was reported that energy-saving lamps cause random false tripping of circuit breakers. In all of these cases these lamps had electronic drivers. An investigation ... Keywords: energy-saving lamp, false tripping, inrush, mitigation, power quality

Vladimir ?uk; Joseph F. G. Cobben; Wil L. Kling

2011-07-01T23:59:59.000Z

149

Sulfur Lamps-The Next Generation of Efficient Light?  

NLE Websites -- All DOE Office Websites (Extended Search)

5 5 Sulfur Lamps-The Next Generation of Efficient Light? The figure above is a schematic of the system installed at the National Air and Space Museum and the DOE headquarters in Washington, D.C., Light from the sulfur lamp is focused by a parabolic reflector so that it enters the light pipe within a small angular cone. Light travels down the pipe, reflecting off the prismatic film (A) that lines the outer acrylic tube. The prismatic film reflects the light through total internal reflection (C), an intrinsically efficient process. Some of the light striking the film (at A) is not reflected and "leaks out" of the pipe walls (B), giving the pipe a glowing appearance. A light ray that travels all the way down the pipe will strike the mirror at the end (D) and return back up the pipe.

150

L Prize Competition Winner 60W Incandesent Replacement Lamp Update  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technology Deployment Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International May 23, 2012 Philips Wins First L Prize 2 * August 3, 2011: Philips announced as winner of 60W replacement bulb category * Product distributed thru commercial and retail channels Image courtesy of Philips -...[O]nce an award is made the authorizing Act directs General Services Administration to develop federal purchasing schedules for solid-state lamps that meet or exceed the specifications laid out in the prize category-so long as it is cost effective. I hope the GSA begins this process soon.‖

151

DuraLamp USA: Proposed Penalty (2010-CE-0912) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) September 9, 2010 DOE alleged in a Notice of Proposed Civil Penalty that DuraLamp USA, Inc. failed to certify a variety of general service fluorescent lamps as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. DuraLamp USA: Proposed Penalty (2010-CE-0912) More Documents & Publications DuraLamp USA: Order (2010-CE-0912)

152

Energy-efficient compact screw-in fluorescent lamp. Final report  

SciTech Connect

A compact fluorescent lamp has been designed and constructed which can replace an incandescent lamp. The lamp is slightly larger than a standard lamp (8 3/4 in. x 3 1/4 in.), but is designed to fit a majority of portable lamp applications. This version, with a core-coil ballast, results in a system efficacy of 54 lumens per watt, with a light output of more than 1800 lumens. This compares favorably with a 100-watt incandescent (17.5 lumens per watt and 1750 lumens light output). The color temperature of 3000/sup 0/K is compatible with an incandescent lamp (2800/sup 0/K). The color rendition index (CRI) is 84. With a solid-state ballast, the efficacy and light output could be increased by 20% (65 l/w, 2200 lumens) and could provide a direct replacement for a three-way, 150-watt incandescent lamp (15 l/w, 2200 lumens).

Morton, E.W.

1982-11-01T23:59:59.000Z

153

Performance of electronic ballasts and lighting controllers with 34-W fluorescent lamps: Final report  

SciTech Connect

This study has measured the performance of energy-saving 34-watt F40, T-12, rapid-start, lite white fluorescent lamps being operated by solid-state ballasts and lighting control equipment. The performances of these lamps are compared with those of 40-watt F40, T-12 rapid-start cool white fluorescent lamp systems studied in the prior phase of this project. With the 34-watt F40 lamps and various solid-state ballasts, system efficacy ranged from 67 to 84 lumens per watt and ballast factor from 0.756 to 0.908. Average system efficacy using the 34-watt lamps exceeded that of systems using 40-watt lamps and the same solid-state ballasts by only 1 percent even though the 34-watt lamps is about 6 percent more efficacious than the 40-watt lamp. This apparent discrepancy is due to increased ballast losses when operating the 34-watt lamps. However, the system efficacy of the 34-watt lamps used with a solid-state ballast exceeded that of a 34-watt, two-lamp system using the standard core-coil ballast by as much as 29 percent. A T-8 fluorescent lamp system with a smaller lamp diameter was also included in the study. Operating this lamp with a solid-state ballast produced a high system efficacy of 90 lumens per watt, a 39 percent improvement over the efficacy of a 40-watt F40 system using the standard core-coil ballast. The use of static controllers with 34-watt F40 lamps can result in excessive flickering (46 percent) and the generation of a second harmonic as high as 96 percent of the fundamental frequency. The dynamic controllers, when used to dim the 34-watt lamps generally cannot be dimmed as low as the 40-watt lamp system without flickering. In general, the 34-watt energy-saving lamps are appropriate as a retrofit to reduce illumination levels. However, for new construction, the 40-watt F40 argon filled lamps cost less, perform better, and provide a more reliable system. 5 refs., 27 figs., 9 tabs.

Verderber, R.R.

1988-06-01T23:59:59.000Z

154

Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps CALiPER Benchmark Report  

Science Conference Proceedings (OSTI)

The Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) Program was established in 2006 to investigate the performance of light-emitting diode (LED) based luminaires and replacement lamps. To help users better compare LED products with conventional lighting technologies, CALiPER has also performed benchmark research and testing of traditional (i.e., non-LED) lamps and fixtures. This benchmark report addresses standard 4-foot fluorescent lamps (i.e., T12 and T8) and the 2-foot by 4-foot recessed troffers in which they are commonly used. This report also examines available LED replacements for T12 and T8 fluorescent lamps, and their application in fluorescent troffers. The construction and operation of linear fluorescent lamps and troffers are discussed, as well as fluorescent lamp and fixture performance, based on manufacturer data and CALiPER benchmark testing. In addition, the report describes LED replacements for linear fluorescent lamps, and compares their bare lamp and in situ performance with fluorescent benchmarks on a range of standard lighting measures, including power usage, light output and distribution, efficacy, correlated color temperature, and the color rendering index. Potential performance and application issues indicated by CALiPER testing results are also examined.

Myer, Michael; Paget, Maria L.; Lingard, Robert D.

2009-01-16T23:59:59.000Z

155

Conservation potential of compact fluorescent lamps in India and Brazil  

SciTech Connect

We evaluate the conservation potential of compact fluorescent lamps (CFLs) for managing the rapidly increasing electrical energy and peak demand in India and Brazil. Using very conservative assumptions, we find that the cost of conserved energy using 16 W CFLs is 4 and 6 times less than the long range marginal cost of electricity for the two countries. The cost of avoided peak installed capacity is 6 and 9.5 times less than the cost of new installed capacity for India and Brazil. The analysis is undertaken from the three separate perspectives of the national economies, the consumers, and the utilities. We find that because residential electricity is subsidized, the consumers have little or no incentive to purchase and install the CFLs, unless they too are subsidized. However, the benefits of CFL installation to the utility are so large that subsidizing them is a paying proposition for the utility are so large that subsidizing them is a paying proposition for the utility in almost all cases. As an illustration of a gradual introduction strategy for CFLs, we calculate a scenario where national savings of the order of US $1.2 million per day for India and US $2.5 million per day for Brazil are reached in 10 years by a small and gradual transfer of subsidy from residential electricity to CFLs. We then explore the barriers to immediate large scale introduction of these lamps in the two countries. Specific technical and marketing problems are identified and discussed, which would require solution before such an introduction can be attempted. Lastly, we discuss the range of policy instruments, in addition to a subsidy scheme, that can be used for promoting the diffusion of these lamps in the domestic and commercial sector. 47 refs., 15 figs., 2 tabs.

Gadgil, A.; Martino Jannuzzi, G. de (Lawrence Berkeley Lab., CA (USA); Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia)

1989-07-01T23:59:59.000Z

156

Energy efficiency lighting on board naval ships: Phase 2 (The T-8 lamp system)  

SciTech Connect

This report describes the development and performance of the T-8 fluorescent lamp-ballast system. Similar to the Phase I effort, the cooperation of the lamp and ballast companies (GTE, North American Philips Lighting, and IOTA Engineering) were required for the successful result. The above companies submitted prototype lamps and ballasts to the Lawrence Berkeley Laboratory Lighting Group to evaluate. The lamp designs were modified as required and the optimum system selected. Two-lamp designs and one ballast were chosen and tested to determine if they met the Navy specifications. The second section describes the lamp-ballast specifications. This section includes the measured thermal performance from an ambient of 10/degree/C to 60/degree/C. 1 ref., 8 figs., 11 tabs.

Verderber, R.R.

1987-01-31T23:59:59.000Z

157

Microwave lamp with multi-purpose rotary motor  

DOE Patents (OSTI)

In a microwave powered electrodeless lamp, a single rotary motor is used to (a) rotate the bulb and (b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooler for providing cooling gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement. 8 figs.

Ury, M.G.; Turner, B.; Wooten, R.D.

1999-02-02T23:59:59.000Z

158

Microwave lamp with multi-purpose rotary motor  

DOE Patents (OSTI)

In a microwave powered electrodeless lamp, a single rotary motor is used to a) rotate the bulb and b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooling for providing cooler gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement.

Ury, Michael G. (Bethesda, MD); Turner, Brian (Myersville, MD); Wooten, Robert D. (Rockville, MD)

1999-01-01T23:59:59.000Z

159

Low pressure arc discharge lamp apparatus with magnetic field generating means  

DOE Patents (OSTI)

A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25 C. 3 figs.

Grossman, M.W.; George, W.A.; Maya, J.

1987-10-06T23:59:59.000Z

160

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

E-Print Network (OSTI)

for Small Businesses in Kenya." Lumina Project Technicalfor Night Market Vendors in Kenya who use LED Lamps Petermany people and businesses in Kenya who participated in this

Johnstone, Peter

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Guidance Concerning Enforcement of EISA 2007 Standards Candelabra Base and Intermediate Base Lamps  

Energy.gov (U.S. Department of Energy (DOE))

The Energy Independence and Security Act of 2007 (EISA 2007) imposed energy conservation standards for candelabra and intermediate base lamps, and those provisions became effective with the statute.

162

Demonstration of LED Retrofit Lamps at the Smithsonian American Art Museum, Washington, DC  

Science Conference Proceedings (OSTI)

This report documents observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy GATEWAY Solid-State Lighting (SSL) Technology Demonstration Program at the Smithsonain American Art Museum in Washington, DC. LED Lamp samples were tested in the museum workshop, temporarily installed in a gallery for feedback, and ultimately replaced all traditional incandescent lamps in one gallery of modernist art at the American Art Museum and partially replacing lamps in two galleries at the Musesum's Renwick Gallery. This report describes the selection and testing process, technology challenges, perceptions, economics, energy use, and mixed results of usign LED replacement lamps in art galleries housing national treasures.

Miller, Naomi J.; Rosenfeld, Scott M.

2012-06-22T23:59:59.000Z

163

EA-1911: Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps  

Energy.gov (U.S. Department of Energy (DOE))

This EA will evaluate the environmental impacts of a proposal to amend energy conservation standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps.

164

Dimming of Compact Fluorescent Lamps Caused By Cold-Air Drafts  

Science Conference Proceedings (OSTI)

This Case Study documents the investigation performed by the New York Port Authority (PA) of the dimming of compact fluorescent lamps (CFLs) in the World Trade Center.

2003-12-31T23:59:59.000Z

165

Power control architectures for cold cathode fluorescent lamp and light emitting diode based light sources.  

E-Print Network (OSTI)

?? In this dissertation, two different energy efficient power supply topologies are introduced for controlling cold cathode fluorescent lamp (CCFL) and high-brightness light emitting diode (more)

Doshi, Montu V.

2010-01-01T23:59:59.000Z

166

A new optimized fluorescent lamp and ballast for low-energy general lighting applications  

SciTech Connect

A new fluorescent lamp and ballast system has been developed which minimizes system input power while maintaining light output close to values provided by conventional lamps and ballasts. The 28-WT-12 lamp designed for the new system utilizes a redesigned electrode structure which allows the lamp to be started in the rapid start manner but operated in an instant start mode to maximize the discharge efficacy (lumens/watt) while reducing lamp cathode power requirements. A matching two-lamp ballast incorporates a solid-state switching device to turn off the cathode heating circuit automatically once the lamps have started. Both lamps and ballasts are physically interchangeable with conventional equipment so that existing luminaires can be converted without luminaire, lampholder, and wiring modifications. This new lamp/ballast system can achieve efficacy values exceeding 80 lm/W--more than 25 percent better than the performance of conventional fluorescent systems of the early 1970's-along with the excellent life and reliability characteristics typical of electromagnetically ballasted systems. Economic analyses indicate that the new system is appropriate for many new commercial general lighting installations, although it is particularly suitable as a retrofit system for installations where power reductions are essential but where conversion costs must be minimized and illumination levels preserved.

Hammer, E.E.; McGowan, T.K.

1983-07-01T23:59:59.000Z

167

The effects of supply harmonics on the performance of compact fluorescent lamps  

SciTech Connect

This paper describes a performance evaluation of ten compact fluorescent lighting systems operated with sinusoidal and distorted voltage waveform conditions. The lamps were either provided with an electronic ballast, a magnetic core ballast or a magnetic core ballast with a power factor correction circuit. The test results show that the electrical performance of the compact fluorescent lamps for both sinusoidal and distorted voltage waveform operation is related to the different types of ballast used. The cost of operation of these compact fluorescent lamps was calculated and compared to the cost of a conventional 60 W incandescent lamp.

Arseneau, R.; Ouellette, M.

1993-04-01T23:59:59.000Z

168

High Efficiency LED Lamp for Solid-State Lighting  

SciTech Connect

This report contains a summary of technical achievements during a three-year project to demonstrate high efficiency, solid-state lamps based on gallium nitride/silicon carbide light-emitting diodes. Novel chip designs and fabrication processes are described for a new type of nitride light-emitting diode with the potential for very high efficiency. This work resulted in the demonstration of blue light-emitting diodes in the one watt class that achieved up to 495 mW of light output at 350 mA drive current, corresponding to quantum and wall plug efficiencies of 51% and 45%, respectively. When combined with a phosphor in Cree's 7090 XLamp package, these advanced blue-emitting devices resulted in white light-emitting diodes whose efficacy exceeded 85 lumens per watt. In addition, up to 1040 lumens at greater than 85 lumens per watt was achieved by combining multiple devices to make a compact white lamp module with high optical efficiency.

James Ibbetson

2006-12-31T23:59:59.000Z

169

Spectral irradiance model for tungsten halogen lamps in 340-850 nm wavelength range  

Science Conference Proceedings (OSTI)

We have developed a physical model for the spectral irradiance of 1 kW tungsten halogen incandescent lamps for the wavelength range 340-850 nm. The model consists of the Planck's radiation law, published values for the emissivity of tungsten, and a residual spectral correction function taking into account unknown factors of the lamp. The correction function was determined by measuring the spectra of a 1000 W, quartz-halogen, tungsten coiled filament (FEL) lamp at different temperatures. The new model was tested with lamps of types FEL and 1000 W, 120 V quartz halogen (DXW). Comparisons with measurements of two national standards laboratories indicate that the model can account for the spectral irradiance values of lamps with an agreement better than 1% throughout the spectral region studied. We further demonstrate that the spectral irradiance of a lamp can be predicted with an expanded uncertainty of 2.6% if the color temperature and illuminance values for the lamp are known with expanded uncertainties of 20 K and 2%, respectively. In addition, it is suggested that the spectral irradiance may be derived from resistance measurements of the filament with lamp on and off.

Ojanen, Maija; Kaerhae, Petri; Ikonen, Erkki

2010-02-10T23:59:59.000Z

170

Table lamp with dynamically controlled lighting distribution and uniformly illuminated luminous shade  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) or other lamps arranged vertically, i.e. one lamp above the other, with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum ensures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. In a particular configuration, the reflective septum is bowl shaped, with the upper CFL sitting in the bowl, and a luminous shade hanging down from the bowl. The lower CFL provides both task lighting and uniform shade luminance. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. However, other types of lamps, including incandescent, halogen, and LEDs can also be used in the fixture. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2002-01-01T23:59:59.000Z

171

Research on Active Power Factor Correction of the Electronic Ballast for High-Pressure Sodium Lamps Based on L6563  

Science Conference Proceedings (OSTI)

In the recent years, there has been a growing interest in the design of high-pressure sodium lamp electronic ballast. Two measures are proposed to improve the power factor of high-pressure sodium lamp electronic ballasts from the definition of harmonic ... Keywords: high-pressure sodium lamps, electronic ballast, active power factor correction, L6563

Sun Jing

2010-06-01T23:59:59.000Z

172

Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

1999-01-01T23:59:59.000Z

173

Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO{sub 2}) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, L.E.; Hackel, L.

1999-10-26T23:59:59.000Z

174

Identification of lamp ballasts containing PCBs. Revised edition. Report no. EPS 2/CC/2  

SciTech Connect

Fluorescent lamp ballast capacitors are among the products that may contain polychlorinated biphenyls (PCBs). Questions about lamp ballasts concern the potential for leakage, the risk of heating and exploding, how to identify a ballast which contains PCBs, and the risk to human health. This study identifies those ballasts containing PCB-filled capacitors; the domestic and foreign manufacturers of PCB-containing ballasts; the total quantity of PCBs used in ballasts; and any potential problems. The study does not identify the risks of human health arising from the use of PCB-ballasts in fluorescent lamps.

1991-01-01T23:59:59.000Z

175

Miniature UV lamp excited by subnanosecond voltage pulses  

SciTech Connect

Energy, time, and spectral characteristics of emission of the second positive system of N{sub 2} molecules in gaseous nitrogen, Ar - N{sub 2} mixture, and air are investigated. An FPG-10 generator with voltage pulse FWHM of 200 and 400 ps and matched-load amplitudes of 14 and 6 kV, respectively, is used to excite gases. It is shown that excitation can be performed in two regimes using this generator. In the first regime a diffuse discharge is formed at atmospheric pressure, which opens ways to design miniature nanosecond UV lamps. A diffuse discharge is formed due to the generation of runaway electrons, with the aid of electrodes having a small radius of curvature and voltage pulses with a sharp leading edge. In the second regime an elevated average radiation power is obtained under excitation by a barrier discharge. However, the operating pressure is lower in this case, and the sizes of the emitting region and the UV pulse width significantly increase. (laser applications and other topics in quantum electronics)

Erofeev, M V; Baksht, E Kh; Tarasenko, Viktor F; Shut'ko, Yu V [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

2010-08-27T23:59:59.000Z

176

Integrated starting and running amalgam assembly for an electrodeless fluorescent lamp  

DOE Patents (OSTI)

An integrated starting and running amalgam assembly for an electrodeless SEF fluorescent lamp includes a wire mesh amalgam support constructed to jointly optimize positions of a starting amalgam and a running amalgam in the lamp, thereby optimizing mercury vapor pressure in the lamp during both starting and steady-state operation in order to rapidly achieve and maintain high light output. The wire mesh amalgam support is constructed to support the starting amalgam toward one end thereof and the running amalgam toward the other end thereof, and the wire mesh is rolled for friction-fitting within the exhaust tube of the lamp. The positions of the starting and running amalgams on the wire mesh are jointly optimized such that high light output is achieved quickly and maintained, while avoiding any significant reduction in light output between starting and running operation.

Borowiec, Joseph Christopher (Schenectady, NY); Cocoma, John Paul (Clifton Park, NY); Roberts, Victor David (Burnt Hills, NY)

1998-01-01T23:59:59.000Z

177

On the Brightness of the Thomson Lamp: A Prolegomenon to Quantum Recursion Theory  

Science Conference Proceedings (OSTI)

Some physical aspects related to the limit operations of the Thomson lamp are discussed. Regardless of the formally unbounded and even infinite number of "steps" involved, the physical limit has an operational meaning in agreement with the Abel sums ...

Karl Svozil

2009-09-01T23:59:59.000Z

178

Demonstration of LED Retrofit Lamps at the Jordan Schnitzer Museum of Art  

SciTech Connect

The Jordan Schnitzer Museum of Art in Eugene, Oregon, houses a remarkable permanent collection of Asian art and antiquities, modern art, and sculpture, and also hosts traveling exhibitions. In the winter and spring of 2011, a series of digital photographs by artist Chris Jordan, titled "Running the Numbers," was exhibited in the Coeta and Donald Barker Special Exhibitions Gallery. These works graphically illustrate waste (energy, money, health, consumer objects, etc.) in contemporary culture. The Bonneville Power Administration and the Eugene Water and Electricity Board provided a set of Cree 12W light-emitting diode (LED) PAR38 replacement lamps (Cree LRP38) for the museum to test for accent lighting in lieu of their standard Sylvania 90W PAR38 130V Narrow Flood lamps (which draw 78.9W at 120V). At the same time, the museum tested LED replacement lamps from three other manufacturers, and chose the Cree lamp as the most versatile and most appropriate color product for this exhibit. The lamps were installed for the opening of the show in January 2011. This report describes the process for the demonstration, the energy and economic results, and results of a survey of the museum staff and gallery visitors on four similar clusters of art lighted separately by four PAR38 lamps.

Miller, Naomi J.

2011-09-01T23:59:59.000Z

179

X-ray Methods in High-Intensity Discharges and Metal-Halide Lamps: X-ray Induced Fluorescence  

SciTech Connect

We describe the use of x-ray induced fluorescence to study metal-halide high-intensity discharge lamps and to measure equilibrium vapor pressures of metal-halide salts. The physical principles of metal-halide lamps, relevant aspects of x-ray-atom interactions, the experimental method using synchrotron radiation, and x-ray induced fluorescence measurements relevant to metal-halide lamps are covered.

Curry, John J.; Lapatovich, Walter P.; Henins, Albert (NIST)

2011-12-09T23:59:59.000Z

180

Determination of the cathode and anode voltage drops in high power low-pressure amalgam lamps  

Science Conference Proceedings (OSTI)

For the first time, cathode and anode drops of powerful low-pressure amalgam lamps were measured. The lamp discharge current is 3.2 A, discharge current frequency is 43 kHz, linear electric power is 2.4 W/cm. The method of determination of a cathode drop is based on the change of a lamp operating voltage at variation of the electrode filament current at constant discharge current. The total (cathode plus anode) drop of voltage was measured by other, independent ways. The maximum cathode fall is 10.8 V; the anode fall corresponding to the maximal cathode fall is 2.4 V. It is shown that in powerful low pressure amalgam lamps the anode fall makes a considerable contribution (in certain cases, the basic one) to heating of electrodes. Therefore, the anode fall cannot be neglected, at design an electrode and ballast of amalgam lamps with operating discharge current frequency of tens of kHz.

Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation); Vasiliev, A. I., E-mail: vasiliev@npo.lit.ru; Kostyuchenko, S. V.; Sokolov, D. V.; Startsev, A. Yu. [Joint Stock Company NPO LIT (Russian Federation); Kudryavtsev, N. N. [Moscow Institute of Physics and Technology (State University) (Russian Federation)

2011-12-15T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Energy-Efficient, High-Color-Rendering LED Lamps Using Oxyfluoride and Fluoride Phosphors  

Science Conference Proceedings (OSTI)

LED lamps using phosphor downconversion can be designed to replace incandescent or halogen sources with a 'warm-white' correlated color temperature (CCT) of 2700-3200 K and a color rendering index (CRI) greater than 90. However, these lamps have efficacies of {approx}70% of standard 'cool-white' LED packages (CCT = 4500-6000 K; CRI = 75-80). In this report, we describe structural and luminescence properties of fluoride and oxyfluoride phosphors, specifically a (Sr,Ca){sub 3}(Al,Si)O{sub 4}(F,O):Ce{sup 3+} yellow-green phosphor and a K{sub 2}TiF{sub 6}:Mn{sup 4+} red phosphor, that can reduce this gap and therefore meet the spectral and efficiency requirements for high-efficacy LED lighting. LED lamps with a warm-white color temperature (3088 K), high CRI (90), and an efficacy of {approx}82 lm/W are demonstrated using these phosphors. This efficacy is {approx}85% of comparable cool-white lamps using typical Y{sub 3}Al{sub 5}O{sub 12}:Ce{sup 3+}-based phosphors, significantly reducing the efficacy gap between warm-white and cool-white LED lamps that use phosphor downconversion.

Setlur, A.; Radkov, E; Henderson, C; Her, J; Srivastava, A; Karkada, N; Kishore, M; Kumar, N; Aesram, D; et al.

2010-01-01T23:59:59.000Z

182

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

NLE Websites -- All DOE Office Websites (Extended Search)

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

183

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

184

Magical Mystery Devices or Not: How do LED Lamps and Luminaires Really Measure-Up?  

SciTech Connect

Solid-state lighting products for general lighting applications are now gaining a market presence, and more and more people are asking, Which of these are good products? Do they perform as claimed? How do they compare? Light Emitting Diodes (LEDs) differ from other light sources enough to require new procedures for measuring their performance and comparing to other lighting options, so both manufacturers and buyers are facing a learning curve. The energy-efficiency community has traditionally compared light sources based on system efficacy: rated lamp lumens divided by power into the system. This doesnt work for LEDs because there are no standard LED lamp packages and no lamp ratings, and because LED performance depends heavily on thermal, electrical, and optical design of complete lighting unit or luminaire. Luminaire efficacy is the preferred metric for LEDs because it measures the net light output from the luminaire divided by power into the system.

Paget, Maria L.; McCullough, Jeffrey J.; Steward, Heidi E.

2008-08-15T23:59:59.000Z

185

Selecting effective fluorescent lamp and ballast for retrofit in the continental United States. Final report  

SciTech Connect

Electrical lighting is a major contributor to daytime peak energy demand, accounting for about 30 percent of total electricity consumption in most Army facilities. Some of this energy may be wasted because many existing lighting systems at Army Installations use outmoded technologies. While recent technology has improved the energy efficiency of all lighting systems, fluorescent lighting-the most widely used interior building lighting-has shown the greatest efficiency gains. Retrofits using high-efficiency fluorescent lamps and ballasts can yield significant operating cost savings. High-efficiency fluorescent lighting systems are widely available, but current information on their performance characteristics is highly technical and not easily accessible to Army facility managers considering retrofit options. This report provides a single, accessible source that summarizes fluorescent lamp and ballast performance characteristics and outlines selection procedures. Fluorescent lamp, Retrofit, Ballast, Lighting. Energy conservation.

Taylor, W.R.

1993-08-01T23:59:59.000Z

186

Spectral distribution of dimmed HID lamps in a plant growth facility  

SciTech Connect

A commercial dimming ballast system for high intensity discharge (HID) lamps has been tested for use in plant growth chambers. The dimming ballast system can be controlled either manually at the dimming panel or by a d.c. voltage from a programmer or computer. Using the dimming system, photosynthetically active radiation can be continuously varied from about 200 to about 2000 ..mu..E m/sup -2/s/sup -1/. This paper shows the effects of dimming on the spectral intensity (400 to 750 nm) of three types of HID lamps measured individually and in combination to achieve a better spectral mix. The lamps used in this study were 400 w metal halide, mercury vapor and high pressure sodium.

Bingham, G.E.; Coyne, P.I.

1979-05-01T23:59:59.000Z

187

Nature of the effect of the ballast volumes of flash lamps on their emission  

SciTech Connect

The cause of the decrease in laser efficiency during pumping by flash lamps with increased ballast volumes is the unproductive loss of radiation, originating from the ballast volumes, and the associated change in the radiation brightness distribution along the length of the lamp. The increase radiation brightness at the electrodes of the light source is not the result of constriction of the discharge or the luminescence of the electrode plasma erosion, but is due to the slowing down of the plasma flows by the surface of the electrodes and to the slowing down of the ionized gas moving from the ballast volumes when it meets the denser plasma of the discharge zone. The profile of the current lines at the electrodes is established and the frequency of the axial oscillations of the plasma in the lamp is determined.

Basov, Yu.G.; Makarov, V.N.; Narkhova, G.I.

1975-11-01T23:59:59.000Z

188

Potential Environmental Impacts from the Metals in Incandescent, Compact Fluorescent Lamp (CFL), and Light-Emitting Diode (LED)  

E-Print Network (OSTI)

), and Light-Emitting Diode (LED) Bulbs Seong-Rin Lim, Daniel Kang, Oladele A. Ogunseitan,,§ and Julie M sources with compact fluorescent lamp (CFL) and light-emitting diode (LED) bulbs that use about 70% and 85 lighting systems are transitioning from incandes- cent to compact fluorescent lamp (CFL) and light

Short, Daniel

189

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

SciTech Connect

Lighting has been one of the fastest growing electric end-uses in China over the last twenty years, with an average annual growth rate of 14%. Fluorescent lighting provides a significant portion of China's lighting need. In 1998, China produced 680 million fluorescent lamps, of which 420 million were linear fluorescent lamps of various diameters (T8 to T12). There are substantial variations both in energy efficiency and lighting performance among locally produced fluorescent lamps. Such variations present a perfect opportunity for policy intervention through efficiency standards to promote the adoption of more efficient fluorescent lamps in China. This paper analyzes China's proposed minimum efficiency standard for fluorescent lamps and presents an assessment of its likely impacts on China's lighting energy consumption and GHG emissions.

Lin, Jiang

2002-04-11T23:59:59.000Z

190

High frequency transformerless electronics ballast using double inductor-capacitor resonant power conversion for gas discharge lamps  

SciTech Connect

A novel high frequency LCLC double resonant electronic ballast has been developed for gas discharge lamp applications. The ballast consists of a half-bridge inverter which switches at zero voltage crossing and an LCLC resonant circuit which converts a low ac voltage to a high ac voltage. The LCLC resonant circuit has two LC stages. The first LC stage produces a high voltage before the lamp is ignited. The second LC stage limits lamp current with the circuit inductance after the lamp is ignited. In another embodiment a filament power supply is provided for soft start up and for dimming the lamp. The filament power supply is a secondary of the second resonant inductor. 27 figs.

Lai, J.S.

1995-06-20T23:59:59.000Z

191

15 KJ FLASH LAMP, POWER CONDITIONING UNIT DESIGNED FOR SAFTY, RELIABILITY & MANUFACTURABILITY*  

SciTech Connect

A 15kJoule, Flash Lamp Power Conditioning Unit has been successfully designed, developed, and deployed in the National Ignition Facility (NIF) Preamplifier Modules (PAM). The primary design philosophy of this power conditioning unit (PCU) is safety, reliability, and manufacturability. Cost reduction over commercially equivalent systems was also achieved through an easily manufactured packaging design optimized to meet NIF requirements. While still maintaining low cost, the PCU design includes a robust control system, fault diagnostic system, and safety features. The pulsed power design includes 6 PFN modules, each including a dual series injection trigger transformer, that drive a total of 12 flash lamp loads. The lamps are individually triggered via a 20kV pulse produced by a 1kV, MCT switched capacitive discharge unit on the primary side of the trigger transformer. The remote control interface includes an embedded controller that captures flash lamp current wave forms and fault status for each shot. The embedded controller provides the flexibility of remotely adjusting both the main drive voltage from 1.6 to 2.5 kV and the trigger voltage from 0 to 20 kV.

James, G; Merritt, B; Dreifuerst, G; Strickland, S

2007-08-07T23:59:59.000Z

192

A Local AFOS MOS Program (LAMP) and its Application to Wind Prediction  

Science Conference Proceedings (OSTI)

The Techniques Development Laboratory has a project called the local AFOS MOS Program (LAMP). Its purpose is the development of a system which can produce at any hour of the day in a Weather Service Forecast Office (WSFO) environment Model Output ...

Harry R. Glahn; David A. Unger

1986-07-01T23:59:59.000Z

193

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents (OSTI)

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp.

Simpson, James E. (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

194

RF driven sulfur lamp having driving electrodes which face each other  

DOE Patents (OSTI)

A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.

Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.

1999-06-22T23:59:59.000Z

195

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents (OSTI)

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp. 18 figs.

Simpson, J.E.

1999-06-08T23:59:59.000Z

196

The Fuzzy Design of the Intelligent System for the Energy-Saving Lamps  

Science Conference Proceedings (OSTI)

In the paper, a intelligent system was proposed. It consists of variable converter and intelligent controller. Variable reactor which concludes variable reactance converter and power converter has wide applications in the soft starting, speed controlling ... Keywords: fuzzy control, variable reactor, intelligent control, power converter, Energy-Saving Lamps

Youxin Yuan; Kaihua Cui; Yiping Xiao; Tieliang Xu

2008-12-01T23:59:59.000Z

197

Issues, Models and Solutions for Triac Modulated Phase Dimming of LED Lamps  

E-Print Network (OSTI)

/a 30 lumens 0.1 Incandescent Bulb 15 W 225 lumens 15 Fluorescent Tube Lamp 10 W 500 lumens 50 White LED bulbs, and fluorescent lights, produce light that is radiated in all directions, LEDs produce a focused especially on the potential of white LED lights, which are an important and newly emerging lighting

Lehman, Brad

198

Energy Performance and Emissions of Electronic Ballasts Powering 4-Foot Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the Worcester Polytechnic Institute, in contract with the EPRI Power Electronics Applications Center (PEAC) to determine the average efficacy (lumens per watt), displacement power factor, total power factor, and current harmonic distortion of modern electronic ballasts powering fluorescent lamps.

2003-12-31T23:59:59.000Z

199

High frequency electronic ballast for HID lamps. Technical progress report, October 1, 1993--December 31, 1994  

SciTech Connect

Electronic Ballast Systems Corp. has been working on the development of highly efficient (94%) electronic ballast for HID lamps (35W,...,400W) providing energy savings of up to thirty five percent (35%) as compared to the only available alternative, the standard core and coil HID ballasts currently on the market.

1995-03-01T23:59:59.000Z

200

Electronic screw-in ballast and improved circline lamp phase I. Final report  

SciTech Connect

A solid state ballast has been designed for the efficient operation of a 10 in circline fluorescent lamp. The circuit can be manufactured using power hybrid technology. Eight discrete component versions of the ballasts have been delivered to LBL for testing. The results show the solid state fluorescent ballast system is more efficient than the core-coil ballasted systems on the market.

Kohler, T.P.

1980-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

A Comparative Verification of Localized Aviation Model Output Statistics Program (LAMP) and Numerical Weather Prediction (NWP) Model Forecasts of Ceiling Height and Visibility  

Science Conference Proceedings (OSTI)

In an effort to support aviation forecasting, the National Weather Services Meteorological Development Laboratory (MDL) has recently redeveloped the Localized Aviation Model Output Statistics (MOS) Program (LAMP) system. LAMP is designed to run ...

David E. Rudack; Judy E. Ghirardelli

2010-08-01T23:59:59.000Z

202

Stress Testing of the Philips 60W Replacement Lamp L Prize Entry  

SciTech Connect

The Pacific Northwest National Laboratory, operated by Battelle for the U.S. Department of Energy, worked with Intertek to develop a procedure for stress testing medium screw-base light sources. This procedure, composed of alternating stress cycles and performance evaluation, was used to qualitatively compare and contrast the durability and reliability of the Philips 60W replacement lamp L Prize entry with market-proven compact fluorescent lamps (CFLs) with comparable light output and functionality. The stress cycles applied simultaneous combinations of electrical, thermal, vibration, and humidity stresses of increasing magnitude. Performance evaluations measured relative illuminance, x chromaticity and y chromaticity shifts after each stress cycle. The Philips L Prize entry lamps appear to be appreciably more durable than the incumbent energy-efficient technology, as represented by the evaluated CFLs, and with respect to the applied stresses. Through the course of testing, all 15 CFL samples permanently ceased to function as a result of the applied stresses, while only 1 Philips L Prize entry lamp exhibited a failure, the nature of which was minor, non-destructive, and a consequence of a known (and resolved) subcontractor issue. Given that current CFL technology appears to be moderately mature and no Philips L Prize entry failures could be produced within the stress envelope causing 100 percent failure of the benchmark CFLs, it seems that, in this particular implementation, light-emitting diode (LED) technology would be much more durable in the field than current CFL technology. However, the Philips L Prize entry lamps used for testing were carefully designed and built for the competition, while the benchmark CFLs were mass produced for retail salea distinction that should be taken into consideration. Further reliability testing on final production samples would be necessary to judge the extent to which the results of this analysis apply to production versions of the Philips L Prize entry.

Poplawski, Michael E.; Ledbetter, Marc R.; Smith, Mark

2012-04-24T23:59:59.000Z

203

Treatability study for removal of leachable mercury in crushed fluorescent lamps  

SciTech Connect

Nonserviceable fluorescent lamps removed from radiological control areas at the Oak Ridge Department of Energy facilities have been crushed and are currently managed as mixed waste (hazardous and radiologically contaminated). We present proposed treatment flowsheets and supporting treatability study data for conditioning this solid waste residue so that it can qualify for disposal in a sanitary landfill. Mercury in spent fluorescent lamps occurs primarily as condensate on high-surface-area phosphor material. It can be solubilized with excess oxidants (e.g., hypochlorite solution) and stabilized by complexation with halide ions. Soluble mercury in dechlorinated saline solution is effectively removed by cementation with zero-valent iron in the form of steel wool. In packed column dynamic flow testing, soluble mercury was reduced to mercury metal and insoluble calomel, loading > 1.2 g of mercury per grain of steel wool before an appreciable breakthrough of soluble mercury in the effluent.

Bostick, W.D.; Beck, D.E.; Bowser, K.T. [and others

1996-02-01T23:59:59.000Z

204

Determination of mercury distribution inside spent compact fluorescent lamps by atomic absorption spectrometry  

Science Conference Proceedings (OSTI)

Highlights: Black-Right-Pointing-Pointer New treatments for CFL are required considering the aim of Directive 202/96/CE. Black-Right-Pointing-Pointer It is shown that most of the mercury introduced into a CFL is in the phosphor powder. Black-Right-Pointing-Pointer Experimental conditions for microwave-assisted sample digestion followed by AAS measurements are described. Black-Right-Pointing-Pointer By washing the glass it is possible to reduce the concentration below legal limits. - Abstract: In this study, spent compact fluorescent lamps were characterized to determine the distribution of mercury. The procedure used in this research allowed mercury to be extracted in the vapor phase, from the phosphor powder, and the glass matrix. Mercury concentration in the three phases was determined by the method known as cold vapor atomic absorption spectrometry. Median values obtained in the study showed that a compact fluorescent lamp contained 24.52 {+-} 0.4 ppb of mercury in the vapor phase, 204.16 {+-} 8.9 ppb of mercury in the phosphor powder, and 18.74 {+-} 0.5 ppb of mercury in the glass matrix. There are differences in mercury concentration between the lamps since the year of manufacture or the hours of operation affect both mercury content and its distribution. The 85.76% of the mercury introduced into a compact fluorescent lamp becomes a component of the phosphor powder, while more than 13.66% is diffused through the glass matrix. By washing and eliminating all phosphor powder attached to the glass surface it is possible to classified the glass as a non-hazardous waste.

Rey-Raap, Natalia [Departamento de Ingenieria Mecanica y Construccion, Universitat Jaume I de Castellon, Av. de Vicent Sos Baynat s/n, 12071 Castellon de la Plana, Espana (Spain); Gallardo, Antonio, E-mail: gallardo@emc.uji.es [Departamento de Ingenieria Mecanica y Construccion, Universitat Jaume I de Castellon, Av. de Vicent Sos Baynat s/n, 12071 Castellon de la Plana, Espana (Spain)

2012-05-15T23:59:59.000Z

205

Integrated-circuit control for two-lamp electronic ballast. Final report  

SciTech Connect

Circuitry is described for a solid-state, high-frequency fluorescent ballast designed to operate two F40 T-12 rapid-start lamps. The circuits are designed to be produced by hybrid integrated circuit (IC) technology. The signal components are produced on a single IC chip; the power transistors are attached to an alumina substrate. The initial IC version reduces the component count by about 50%. The cost of each IC in 500K lots is $0.70, replacing discrete parts costing $2.25. Additional savings of more than $1.00 per unit are realized by the decreased assembly time and improved reliability of the ICs. The system performance (two-lamp F40) was compared to the discrete version of the ballast and to an efficient core-coil ballast and found to be 6% less and 20% more efficient, respectively. The decrease in efficiency relative to the discrete version of the ballast is due to retaining some power to the filaments during operation in order to maintain normal lamp life.

Kohler, T.P.

1982-11-01T23:59:59.000Z

206

Experimental and theoretical investigations on the warm-up of a high-pressure mercury discharge lamp  

SciTech Connect

Modern high-pressure discharge lamps are forced to provide instant light and hot relight capabilities - if possible at lower power units. A detailed understanding of the warm-up of high-pressure discharge lamps is therefore required. Complex fluid model codes were developed for the past years including more and more processes like two-dimensional treatment of convection trying to provide a more comprehensive and consistent description of high-pressure discharge lamps. However, there is a lack of experimental data to examine the performance of these models. This work provides a very complete set of geometrical, electrical, spectroscopic, and thermographic data according to the warm-up of a high-pressure mercury discharge lamp that is compared to the results of a state of the art fluid code. Quantitative agreement is achieved for single parameters like wall temperatures. But the paper also reveals the need for further investigations and improvements of the code.

Zalach, J.; Franke, St.; Schoepp, H. [Leibniz Institute for Plasma Science and Technology, Felix-Hausdorff-Str. 2, D-17489 Greifswald (Germany); Araoud, Z.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, rte de Kairouan, 5019 Monastir (Tunisia); Zissis, G. [Laboratoire Plasma et Conversion d'Energie, 118 rte Narbonne, Bat3R2, 31062 Toulouse (France)

2011-03-15T23:59:59.000Z

207

Performance of electronic ballasts and other new lighting equipment: (Phase 2, The 34-watt F40 rapid start T-12 fluorescent lamp): Final report  

SciTech Connect

This study has measured the performance of energy-saving 34-watt F40, T-12, rapid-start, lite white fluorescent lamps being operated by solid-state ballasts and lighting control equipment. The performances of these lamp systems are compared with those of 40-watt F40, T-12 rapid-start cool white fluorescent lamp systems studied in the prior phase of this project. With the 34-watt F40 lamps and various solid-state ballasts, system efficacy ranged from 67 to 84 lumens per watt and ballast factor from 0.756 to 0.908. Average system efficacy using the 34-watt lamps exceeded that of systems using 40-watt lamps and the same solid-state ballasts by only 1 percent even though the 34-watt lamps is about 6 percent more efficacious than the 40-watt lamp. This apparent discrepancy is due to increased ballast losses when operating the 34-watt lamps. However, the systems efficacy of the 34-watt lamps used with a solid-state ballast exceeded that of a 34-watt, two-lamp system using the standard core-coil ballast by as much as 29 percent. A T-8 fluorescent lamp system with a smaller lamp diameter was also included in the study. Operating this lamp with a solid-state ballast produced a high system efficacy of 90 lumens per watt, a 39 percent improvement over the efficacy of a 40-watt F40 system using the standard core-coil ballast. The use of static controllers with 34-watt F40 lamps can result in excessive flickering (46 percent) and the generation of a second harmonic as high as 96 percent of the fundamental frequency. The dynamic controllers, when used to dim the 34-watt lamps generally cannot be dimmed as low as the 40-watt lamp system without flickering. In general, the 34-watt energy-saving lamps are appropriate as a retrofit to reduce illumination levels. However, for new construction, the 40-watt F40 argon filled lamps cost less, perform better, and provide a more reliable system. 5 refs., 27 figs., 9 tabs.

Verderber, R.R.; Morse, O.

1988-02-01T23:59:59.000Z

208

A New Rb Lamp Exciter Circuit for Rb atomic clocks and Studies on Transition from Ring to Red mode  

E-Print Network (OSTI)

In this paper we describe the development of novel RF exciter circuit for electrode less Rb lamp. The lamp exciter circuit is a RF oscillator with a a new configuration operating at 60 to 65 MHz frequency with 3 to 4 watt power. The Rb lamp is used in exciting the ground state hyperfine transitions in Rb atom in a glass cell placed inside a tuned microwave cavity, As the frequency of these hyperfine transitions is very stable it is used in the development of Rb atomic clock by phase locking the oven controlled crystal oscillator (OCXO) to this atomic transition frequency. The details of the Rb lamp exciter are presented in the paper.The Lamp is ideally operated in ring mode as in this mode the linewidth is narrow and there is no self reversal. However, high temperature and RF excitation power may drive the Rb lamp to red mode which gives rise to line broadening and self reversal. It is the experience that mode change from ring to red deteriorates the atomic signal strength and S/N. In this paper the reasons of mode change are also discussed.

Savita Singh; Bikash Ghosal; G M Saxena

2010-11-10T23:59:59.000Z

209

The Jamming point street-lamp in the world of granular media  

E-Print Network (OSTI)

The Jamming of soft spheres at zero temperature, the J-point, has been extensively studied both numerically and theoretically and can now be considered as a safe location in the space of models, where a street lamp has been lit up. However, a recent work by Ikeda et al, 2013 reveals that, in the Temperature/Packing fraction parameter space, experiments on colloids are actually rather far away from the scaling regime illuminated by this lamp. Is it that the J-point has little to say about real system? What about granular media? Such a-thermal, frictional, systems are a-priori even further away from the idealized case of thermal soft spheres. In the past ten years, we have systematically investigated horizontally shaken grains in the vicinity of the Jamming transition. We discuss the above issue in the light of very recent experimental results. First, we demonstrate that the contact network exhibits a remarkable dynamics, with strong heterogeneities, which are maximum at a packing fraction phi star, distinct and smaller than the packing fraction phi dagger, where the average number of contact per particle starts to increase. The two cross-overs converge at point J in the zero mechanical excitation limit. Second, a careful analysis of the dynamics on time scales ranging from a minute fraction of the vibration cycle to several thousands of cycles allows us to map the behaviors of this shaken granular system onto those observed for thermal soft spheres and demonstrate that some light of the J-point street-lamp indeed reaches the granular universe.

Corentin Coulais; Robert P. Behringer; Olivier Dauchot

2013-05-03T23:59:59.000Z

210

A high-efficiency indirect lighting system utilizing the solar 1000 sulfur lamp  

SciTech Connect

High-lumen light sources represent unique challenges and opportunities for the design of practical and efficient interior lighting systems. High-output sources require a means of large-scale distribution and avoidance of high-luminance glare while providing efficient delivery. An indirect lighting system has been developed for use with a 1,000 Watt sulfur lamp that efficiently utilizes the high-output source to provide quality interior lighting. This paper briefly describes the design and initial testing of this new system.

Siminovitch, M.; Gould, C.; Page, E.

1997-06-01T23:59:59.000Z

211

Super-radiance in the sodium resonance lines from sodium iodide arc lamps  

Science Conference Proceedings (OSTI)

Super-radiance observed within the centers of the sodium resonance D lines emitted by arc lamps containing sodium iodide as additive in a high-pressure mercury plasma environment was studied by high-resolution emission spectroscopy. The spectral radiance of these self-reversed lines including super-radiance was simulated by considering a local enhancement of the source function due to the presence of an additional source of radiation near the arc wall. Causes of this hitherto unrecognized source of radiation are given.

Karabourniotis, D. [Department of Physics, Institute of Plasma Physics, University of Crete, 71003 Heraklion (Greece); Drakakis, E. [Department of Electrical Engineering, Technological Educational Institute, Heraklion (Greece)

2010-08-09T23:59:59.000Z

212

Experimental methodology for determining the system performance of fluorescent lamp, ballast, fixture combinations operating under realistic application conditions  

SciTech Connect

To meet the need for accurate performance data, an experimental method for determining the performance of lamp, ballast, and luminaire combinations operating under a broad range of realistic conditions was developed. The methodology employs a two-part experimental procedure. The first part uses a temperature-controlled luminous flux integrator to characterize the thermal performance of each lamp/ballast combination. This performance characterization is expressed in terms of light output and efficacy as a function of variations in minimum lamp wall temperature (MLWT) and is generated for the range of temperatures typically encountered in interior lighting applications. The second procedure uses a luminaire/plenum simulator to determine the specific MLWT that exists in a particular luminaire application as a function of luminaire type, mounting configuration, plenum integration, and room air temperature. The MLWTs thus measured may be used in conjunction with the lamp/ballast performance data to determine application-specific values of light output and efficacy for a given lamp/ballast/luminaire system.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.

1984-11-01T23:59:59.000Z

213

Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg.sup.196 enrichment  

DOE Patents (OSTI)

The present invention is directed to a method of eliminating the cold spot zones presently used on Hg.sup.196 isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

Grossman, Mark W. (Belmont, MA)

1993-01-01T23:59:59.000Z

214

Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg[sup 196] enrichment  

DOE Patents (OSTI)

The present invention is directed to a method of eliminating the cold spot zones presently used on Hg[sup 196] isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

Grossman, M.W.

1993-02-16T23:59:59.000Z

215

Energy Savings and NOx Emissions Reduction Potential from the 2012 Federal Legislation to Phase Out Incandescent Lamps in Texas  

E-Print Network (OSTI)

This report provides detailed information about the potential savings from the 2012 Federal Legislation to phase out incandescent lamps and the NOx emissions reduction from the replacement of incandescent bulbs with Compact Fluorescent Lamps (CFL). In Texas, this analysis includes the savings estimates from both the annual and Ozone Season Day (OSD) NOx reductions. The NOx emissions reduction in this analysis are calculated using estimated emissions factors for 2007 from the US Environmental Protection Agency (US EPA) eGRID database, which had been specially prepared for this purpose.

Liu, Zi; Baltazar, Juan Carlos; Haberl, Jeff; Soman, Rohit

2010-03-01T23:59:59.000Z

216

Water-Heating Dehumidifier - Energy Innovation Portal  

Hydrogen and Fuel Cell; Hydropower, Wave and Tidal; Industrial Technologies; Solar ... When the tank of water heater is full of hot water or a ...

217

THERMAL ANNEALING OF ZNO FILMS USING HIGH-DENSITY PLASMA ARC LAMPS  

Science Conference Proceedings (OSTI)

Nanostructured materials are rarely synthesized with appropriate phase and/or morphology. In this study, critical additional of as-synthesized nanostructured materials, such as annealing and/or activation of dopants, are addressed using infrared plasma arc lamps (PAL) over areas as large as 1,000 cm2. The broad spectral range of the PAL and the spectral variation of light absorption in nanostructured materials make the selection of processing parameters extremely difficult, posing a major technological barrier. In this study, the measurement of the surface temperature using various techniques for ZnO films on crystalline silicon wafers is discussed. An energy transport model for the simulation of rapid thermal processing using PAL is presented. The experimental and computational results show that the surface temperature cannot be measured directly and that computer simulation results are an effective tool for obtaining accurate data on processing temperatures.

Sabau, Adrian S [ORNL; Dinwiddie, Ralph Barton [ORNL; Xu, Jun [ORNL; Angelini, Joseph Attilio [ORNL; Harper, David C [ORNL

2011-01-01T23:59:59.000Z

218

NIST energy related inventions: Electronic starter device for fluorescent lamps. Interim report, August--October, 1997  

SciTech Connect

From the Scope of Work document which accompanied the original proposal, three silicon devices were anticipated for development, simulation, and quality assurance fabrication. The status of these are in the same format as the Scope of Work...Attachment-A-: Task 1--design and simulation; Task 2--prototype tooling; Task 3--test engineering; Task 4--product tooling; Task 5--package tooling/manufacturing design and assembly. It is felt the program will meet it`s stated goals of producing a low cost, high performance fluorescent lamp starter which will lower the acquisition and operating cost of fluorescent technology...thus saving significant amounts of energy. The likelihood of success is even greater, now that the TN22 component has been qualified. The challenges of creating a custom ASIC, while still significant, are within the skill and expertise level or the assigned engineers.

Johnson, S.A.

1997-12-01T23:59:59.000Z

219

Mercury reduction studies to facilitate the thermal decontamination of phosphor powder residues from spent fluorescent lamps  

SciTech Connect

This work investigates the thermal release of mercury from phosphor powder of spent fluorescent lamps. The treatment conditions and the ability of various reducing agents (primarily sodium borohydride) to lower the overall heating temperature required to improve the release of Hg have been evaluated. Hg species in samples were monitored in a thermal desorption atomic absorption spectrometer system, and total mercury was analyzed in a cold vapor atomic absorption spectrometer. Sodium borohydride was the best reducing agent among the ones studied. However, citric acid presented a high capacity to weaken mercury bonds with the matrix. When the sample was crushed with sodium borohydride for 40 min in a mass ratio of 10:1 (sample:reducing agent) and submitted to thermal treatment at 300 deg. C for 2 h, the concentration of mercury in a phosphor powder sample with 103 mg kg{sup -1} of mercury reached 6.6 mg kg{sup -1}.

Alves Durao, Walter [Chemistry Department, Federal University of Minas Gerais (UFMG), Cidade Universitaria 30.123-970 Belo Horizonte, MG (Brazil); Andreva de Castro, Camila [Chemistry Engineering Department, Federal University of Minas Gerais (UFMG) (Brazil); Carvalhinho Windmoeller, Claudia [Chemistry Department, Federal University of Minas Gerais (UFMG), Cidade Universitaria 30.123-970 Belo Horizonte, MG (Brazil)], E-mail: claucw@netuno.lcc.ufmg.br

2008-11-15T23:59:59.000Z

220

Archaeological data visualization in VR: analysis of lamp finds at the great temple of petra, a case study  

Science Conference Proceedings (OSTI)

We present the results of an evaluation of the ARCHAVE system, an immersive virtual reality environment for archaeological research. ARCHAVE is implemented in a Cave. The evaluation studied researchers analyzing lamp and coin finds throughout the excavation ... Keywords: archaeological data analysis, immersive virtual reality interfaces, scientific visualization

Daniel Acevedo; Eileen Vote; David H. Laidlaw; Martha S. Joukowsky

2001-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Application of a three-dimensional model for a study of the energy transfer of a high-pressure mercury horizontal lamp  

Science Conference Proceedings (OSTI)

This paper is devoted to study the dynamics of a discharge lamp with high intensity in a horizontal position. As an example of application, we chose the high-pressure mercury lamp. For this, we realized a three-dimensional model, a stable and powered DC. After the validation of this model, we used it to reproduce the influence of some parameters that have appeared on major transport phenomena of mass and energy in studying the lamp operating in a horizontal position. Indeed, the mass of mercury and the electric current are modified and the effect of convective transport is studied.

Ben Hamida, M. B.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

2012-06-15T23:59:59.000Z

222

Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet. 7 figs.

Ury, M.; Sowers, F.; Harper, C.; Love, W.

1998-11-24T23:59:59.000Z

223

Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet.

Ury, Michael (Bethesda, MD); Sowers, Frank (Frederick, MD); Harper, Curt (Wheaton, MD); Love, Wayne (Olney, MD)

1998-01-01T23:59:59.000Z

224

Mechanical design of PlayLamp : a minimally intrusive device for recording the behavior of children at-risk of developmental disorders  

E-Print Network (OSTI)

This thesis paper documents the design process, decisions, and outcomes of the design of the physical form factor of PlayLamp, a device for video and audio recording the development of children at-risk of having developmental ...

Steger, Stephen Andrew

2008-01-01T23:59:59.000Z

225

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

Science Conference Proceedings (OSTI)

Creation of light for work, socializing, and general illumination is a fundamental application of technology around the world. For those who lack access to electricity, an emerging and diverse range of LED based lighting products hold promise for replacing and/or augmenting their current fuel-based lighting sources that are costly and dirty. Along with analysis of environmental factors, economic models for total cost-ofownership of LED lighting products are an important tool for studying the impacts of these products as they emerge in markets of developing countries. One important metric in those models is the minimum illuminance demanded by end-users for a given task before recharging the lamp or replacing batteries. It impacts the lighting service cost per unit time if charging is done with purchased electricity, batteries, or charging services. The concept is illustrated in figure 1: LED lighting products are generally brightest immediately after the battery is charged or replaced and the illuminance degrades as the battery is discharged. When a minimum threshold level of illuminance is reached, the operational time for the battery charge cycle is over. The cost to recharge depends on the method utilized; these include charging at a shop at a fixed price per charge, charging on personal grid connections, using solar chargers, and purchasing dry cell batteries. This Research Note reports on the observed"charge-triggering" illuminance level threshold for night market vendors who use LED lighting products to provide general and task oriented illumination. All the study participants charged with AC power, either at a fixed-price charge shop or with electricity at their home.

Johnstone, Peter; Jacobson, Arne; Mills, Evan; Radecsky, Kristen

2009-03-21T23:59:59.000Z

226

GLASS AND GLASS-DERIVATIVE SEALS FOR USE IN ENERGY-EFFICIENT FUEL CELLS AND LAMPS  

DOE Green Energy (OSTI)

As the project approaches the end of the first year, the materials screening components of the work are ahead of schedule, while all other tasks are on schedule. For solid oxide fuel cells (SOFC), a series of 16 sealing glasses have been prepared and characterized. Traditional melting was used to prepare all of the glasses, and the sol-gel approach has been used to prepare some of the glasses as well as other compositions that might be viable because of the low processing temperatures afforded by the sol-gel method. The glass characterization included measurements of the viscosity and thermal expansion of the glasses, as well as the thermal expansion of the partly crystalline glass ceramics. In addition, the wetting and sintering behavior of all glasses has been measured, as well as the crystallization behavior. The time and temperature at which crystalline phases form from the glasses has been determined for all of the glasses. Each glass ceramic contains at least two crystalline phases, and most of the crystalline phases have been positively identified. Room temperature leak testing has been completed for all sealants, and experiments are in progress to determine the DC electrochemical degradation and degradation in wet hydrogen. The second component of the work, focused on seals for higher-temperature discharge lighting, has focused on determining the phase relations in the yttria--alumina--silica system at various silica levels. Again, traditional melting and sol-gel synthesis have been employed, and the sol-gel method was successful for preparing new phases that were discovered during the work. High temperature diffraction and annealing studies have clarified the phase relations for the samples studies, although additional work remains. Four new phases have been identified and synthesized in pure form, from which full structure solutions were obtained as well as the anisotropic thermal expansion for each phase. Functional testing of lamps are on on-going and will be analyzed during year 2 of the contract.

Scott Misture; Arun Varshneya; Matthew Hall; Sylvia DeCarr; Steve Bancheri

2004-08-15T23:59:59.000Z

227

Glass and glass-derivative seals for use in energy-efficient fuel cells and lamps  

DOE Green Energy (OSTI)

For solid oxide fuel cells (SOFC), a series of 18 sealing glasses have been prepared and characterized. From the whole design space, several glasses were ''downselected'' and studied in detail to describe their behaviors in simulated fuel cell environments. One of the glasses was found to outperform all others, including the well-known G18 sealant developed at Pacific Northwest National Laboratory. The new glass composition showed lower bulk electrical conductivity, excellent sealing and wetting behavior when sealing under applied load, and qualitatively superior performance when exposed to wet hydrogen for 800 hours. Traditional melting was used to prepare all of the glasses that were studied in detail. The sol-gel approach was used to synthesize several compositions, but it was found that the glasses crystallized very rapidly during heating, precluding sealing. The glass characterization included measurements of the viscosity and thermal expansion of the glasses, as well as the thermal expansion of the partly crystalline glass ceramics. In addition, the wetting and sintering behavior of all glasses has been measured, as well as the crystallization behavior. The time and temperature at which crystalline phases form from the glasses has been determined for all of the glasses. Each glass ceramic contains at least two crystalline phases, and most of the crystalline phases have been positively identified. The body of fundamental data provides a platform for future developments for high temperature sealants, and the newly-developed glass compositions appear promising for large-scale testing. The second component of the work, focused on seals for higher-temperature discharge lighting, has focused on determining the phase relations in the yttria-alumina-silica system at various silica levels. Functional testing of one of the candidate sealants demonstrated that it performs well in current HID lighting applications. Further testing is required to evaluate its performance in next-generation lamps that operate at higher temperatures, but the baseline phase equilibria and crystallization behavior has been established for additional development. Again, traditional melting and sol-gel synthesis have been employed, and the sol-gel method was successful for preparing new phases that were discovered during the work. Four new phases have been identified and synthesized in pure form, from which full structure solutions were obtained as well as the anisotropic thermal expansion for each phase.

Scott Misture; Arun Varshineya; Matthew Hall; Sylvia DeCarr; Steve Bancheri

2005-07-28T23:59:59.000Z

228

Process for environmentally safe disposal of used fluorescent lamp potted ballast assemblies with component part reclamation and/or recycling  

SciTech Connect

A process is described for the environmentally safe and economical disposal of used fluorescent lamp potted ballast housing assemblies comprising removing from the housing the potted assembly with its embedded electrical component assemblies including a component capacitor containing environmentally hazardous material PCB's; after or before such removing, immersing the potted assembly in a cryogenic bath and freezing the same to reader the potting sufficiently brittle to fragment into small pieces upon being impacted; impacting the potting thoroughly to crush and fragment the same into small pieces and to cleanly remove substantially all traces of the potting from all the electrical components and parts embedded therein and without imparting damage to the components and parts; disconnecting the component containing the environmentally hazardous material; and incinerating only the component containing the environmentally hazardous material, leaving all other components and parts including the housing and potting fragments for salvage, re-use and/or recycling.

Nardella, A.; Norian, B.

1993-07-27T23:59:59.000Z

229

Exploration of illumination concepts for underground coal mines. Appendix E. Electronic ballast for the Lucalox high pressure sodium lamp. Final report  

SciTech Connect

The report documents the results of an investigation to develop solid-state ballasts for Lucalox high-pressure sodium lamps. The ballasts were to be used in the modified and new portable and machine-mounted lighting systems designed by the Crouse-Hinds Co., per tasks I through IV of Contract No. H022065.

1976-07-20T23:59:59.000Z

230

Erik Page  

NLE Websites -- All DOE Office Websites (Extended Search)

Michael J. Siminovitch. "New Energy Efficient Torchieres Ready for Hot Torchiere Market." Energy Efficiency in Household Appliances (1997). Download: PDF (461.52 KB) 1 2 next ...

231

Energy efficiency standards for residential and commercial equipment: Additional opportunities  

E-Print Network (OSTI)

washer Dishwashing Dishwasher Lighting Torchiere Spacea higher-efficiency dishwasher. ** This category does notPool pump Ceiling fan Dishwasher Torchiere Refrigerator Room

Rosenquist, Greg; McNeil, Michael; Iyer, Maithili; Meyers, Steve; McMahon, Jim

2004-01-01T23:59:59.000Z

232

Demonstration of LED Retrofit Lamps at an Exhibit of 19th Century Photography at the Getty Museum  

SciTech Connect

This document is a report of observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy (DOE) GATEWAY Demonstration Program. The program supports demonstrations of high-performance solid-state lighting (SSL) products in order to develop empirical data and experience with in-the-field applications of this advanced lighting technology. The DOE GATEWAY Demonstration Program focuses on providing a source of independent, third-party data for use in decision-making by lighting users and professionals; this data should be considered in combination with other information relevant to the particular site and application under examination. Each GATEWAY Demonstration compares SSL products against the incumbent technologies used in that location. Depending on available information and circumstances, the SSL product may also be compared to alternate lighting technologies. Though products demonstrated in the GATEWAY program may have been prescreened for performance, DOE does not endorse any commercial product or in any way guarantee that users will achieve the same results through use of these products. This report reviews the installation and use of LED PAR38 lamps to light a collection of toned albument photographic prints at the J. Paul Getty Museum in Malibu, California. Research results provided by the Getty Conservation Institute are incorporated and discussed.

Miller, Naomi J.; Druzik, Jim

2012-03-02T23:59:59.000Z

233

DOE CALiPER Program, Report 20.1 Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps  

Science Conference Proceedings (OSTI)

This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members ranking of color quality did not always match the rank according to the color rendering index (CRI).

Royer, Michael P.; Poplawski, Michael E.; Miller, Naomi J.

2013-10-01T23:59:59.000Z

234

Atomic gas temperature in a nonequilibrium high-intensity discharge lamp determined from the red wing of the resonance mercury line 254 nm  

Science Conference Proceedings (OSTI)

For developing low-wattage high intensity discharge (HID) lamps, a better understanding of the relatively unexplored nonequilibrium phenomena is essential. This needs interpretation of diagnostic results by methods free from equilibrium assumptions. In this paper, the atomic temperature is determined from the simulation of a quasistatic broadened resonance line by distinguishing between atomic temperature and excitation temperature in the equation of radiative transfer. The proposed method is applied to the red wing of the resonance mercury line 254 nm emitted from a HID lamp working on ac. The experimental results show severe deviation from local thermodynamic equilibrium. More than one thousand degrees difference was obtained between atomic and electron temperatures at the maximum current phase.

Drakakis, E. [Technological Educational Institute, Department of Electrical Engineering, 71004 Heraklion (Greece); Karabourniotis, D. [Institute of Plasma Physics, Department of Physics, University of Crete, 71003 Heraklion (Greece)

2012-09-01T23:59:59.000Z

235

DOE/EA-1664: Environmental Assessment for 10 CFR 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps (June 2009)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4 4 Environmental Assessment for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps June 2009 16-i CHAPTER 16. ENVIRONMENTAL ASSESSMENT TABLE OF CONTENTS 16.1 INTRODUCTION ......................................................................................................... 16-1 16.2 AIR EMISSIONS ANALYSIS...................................................................................... 16-1 16.2.1 Air Emissions Descriptions............................................................................................ 16-1 16.2.2 Air Quality Regulation................................................................................................... 16-3 16.2.3 Global Climate Change..................................................................................................

236

Assessment of Electrical, Efficiency, and Photometric Performance of Advanced Lighting Sources: Dimmable Advanced Lighting Technolog ies -- Electronic (Hot and Cold Cathode) Compact Fluorescent Lamps and Ballasts  

Science Conference Proceedings (OSTI)

This EPRI Technical Update (EPRI report 1018477) is one of four in a series that addresses basic dimming performance of advanced lighting sourceselectronic (hot and cold cathode) compact fluorescent lamps and ballasts Chapter 1 discusses basic lighting control, the importance of considering power quality in lighting control, lighting control methods and parameters, and the advantages and future of lighting control. Chapter 2 addresses in more depth dimming methods used in advanced lighting sources and co...

2008-12-19T23:59:59.000Z

237

Miscellaneous electricity use in U.S. homes  

E-Print Network (OSTI)

efficiency of fans for fuel-fired furnaces, and replacing halogen torchieres with more efficient CFL

Sanchez, Marla C.; Koomey, Jonathan G.; Moezzi, Mithra M.; Meier, Alan; Huber, Wolfgang

1999-01-01T23:59:59.000Z

238

Test and Evaluation of a Hybrid Desiccant Dehumidifier  

Science Conference Proceedings (OSTI)

Dehumidification technology is being investigated for potential savings in building air conditioning systems. The potential for savings lies in separating the sensible and the latent cooling loads to more efficiently address the combined conditioning needs of the space. The Munters DryCool HD combined desiccant/vapor compression system was tested in the EPRI Knoxville psychrometric chambers. The system was tested in the laboratory for a host of indoor and outdoor conditions. The system provides cooling a...

2011-05-09T23:59:59.000Z

239

Analysis and performance of radial flow rotary dessicant dehumidifiers  

SciTech Connect

A model is developed to predict the steady periodic performance of a radial flow desiccant wheel. The model is expressed in terms of the same dimensionless parameters that are commonly used in modeling of the conventional axial flow desiccant wheel. In addition a dimensionless geometrical ratio of the volume of the matrix to the volume of the wheel core is found to affect the performance of the wheel. A finite difference technique on staggered grid is used to discretize the governing dimensionless equations. The discretized equations are solved to predict the performance of the desiccant wheel at given values of operation parameters. A sensitivity study is carried out to investigate the effect of changing any of these parameters on the performance of the wheel. The performance of the radial flow desiccant wheel having the same values of the operation parameters.

Elsayed, M.M.; Chamkha, A.J. [Kuwait Univ., Safat (Kuwait). Mechanical and Industrial Engineering Dept.

1997-02-01T23:59:59.000Z

240

Development of a simplified model for cooling and dehumidifying coils  

E-Print Network (OSTI)

Precise understanding of the cooling coil in air handler units is vital to assure the proper temperature and humidity in conditioned space while minimizing the associated costs of operating the air conditioning system. Several models have been developed in the past to characterize the overall heat transfer coefficient of this component. However, these models require specific details about the coil construction which make them impractical for in-situ applications. A simplified engineering model suitable for application to existing coils in the field is therefore needed in the heating, ventilating, and air conditioning (HVAC) industry. The objective of this study is to develop a simplified model suitable for use with field measured data to characterize the overall heat transfer coefficient of in-situ water-to-air cooling coils. This model uses the electrical resistance analogy to treat the heat transfer process in the coil. Field measured data combined with a theoretical analysis are the basis for the development of the model. Non-linear regressions are applied to the data to trace the heat transfer behavior of the coil. The coefficients obtained from the regressions account for the physical characteristics of the coil under study as well as for the properties of the fluids involved (air and water). The calibration of these parameters to data generated by a coil manufacturer's simulation program allows the application of the resulting model to different types of cooling coils with different characteristics. Correlations are developed to predict the coefficients of the model and make it suitable for application to water cooling coils with a range of physical characteristics. The resulting model is validated by testing it on data from two different buildings at Texas excellent in both cases, predicting the thermal resistance of the coils and the return water temperature with an average deviation of 3.5% and 1.2 'F, respectively. Finally, the model is used to develop algorithms to simulate the two most common chilled water loops in buildings: the two-way valve and the blending station arrangement. These algorithms are incorporated in software developed at the Energy Systems Laboratory at Texas A&M University, College Station, which is used to simulate building heating, cooling and energy consumption based on a simplified air-side model. This addition enhances the capability of the software to simulate the response of the water-side to changes occurring in the space conditioning area, providing, in this way, a clear picture of the heat transfer phenomena that occurs in the cooling coil. The upgraded software was tested on a campus building and there was good agreement between the conditions.

Maldonado, Eliezer

1997-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Phosphors for LED lamps  

DOE Patents (OSTI)

A phosphor, a phosphor blend including the phosphor, a phosphor prepared by a process, and a lighting apparatus including the phosphor blend are disclosed. The phosphor has the formula (Ca.sub.1-p-qCe.sub.pK.sub.q).sub.xSc.sub.y(Si.sub.1-rGa.sub.r).sub.zO.su- b.12+.delta. or derived from a process followed using disclosed amounts of reactants. In the formula, (0

Murphy, James Edward; Manepalli, Satya Kishore; Kumar, Prasanth Nammalwar

2013-08-13T23:59:59.000Z

242

Decontamination Strategy for Large Area and/or Equipment Contaminated with Chemical and Biological Agents using a High Energy Arc Lamp (HEAL)  

Science Conference Proceedings (OSTI)

A strategy for the decontamination of large areas and or equipment contaminated with Biological Warfare Agents (BWAs) and Chemical Warfare Agents (CWAs) was demonstrated using a High Energy Arc Lamp (HEAL) photolysis system. This strategy offers an alternative that is potentially quicker, less hazardous, generates far less waste, and is easier to deploy than those currently fielded by the Department of Defense (DoD). For example, for large frame aircraft the United States Air Force still relies on the combination of weathering (stand alone in environment), air washing (fly aircraft) and finally washing the aircraft with Hot Soapy Water (HSW) in an attempt to remove any remaining contamination. This method is laborious, time consuming (upwards of 12+ hours not including decontamination site preparation), and requires large amounts of water (e.g., 1,600+ gallons for a single large frame aircraft), and generates large amounts of hazardous waste requiring disposal. The efficacy of the HEAL system was demonstrated using diisopropyl methyl phosphonate (DIMP) a G series CWA simulant, and Bacillus globigii (BG) a simulant of Bacillus anthracis. Experiments were designed to simulate the energy flux of a field deployable lamp system that could stand-off 17 meters from a 12m2 target area and uniformly expose a surface at 1360 W/m2. The HEAL system in the absence of a catalyst reduced the amount of B. globigii by five orders of magnitude at a starting concentration of 1.63 x 107 spores. In the case of CWA simulants, the HEAL system in the presence of the catalyst TiO2 effectively degraded DIMP sprayed onto a 100mm diameter Petri dish in 5 minutes.

Schoske, Richard [ORNL; Kennedy, Patrick [ORNL; Duty, Chad E [ORNL; Smith, Rob R [ORNL; Huxford, Theodore J [ORNL; Bonavita, Angelo M [ORNL; Engleman, Greg [ORNL; Vass, Arpad Alexander [ORNL; Griest, Wayne H [ORNL; Ilgner, Ralph H [ORNL; Brown, Gilbert M [ORNL

2009-04-01T23:59:59.000Z

243

Lamps in the Leaping Over  

E-Print Network (OSTI)

dusgser gyi nya mo khor lo bskor bai rgyud chen po: /rang byung lhun grub bras bu n/ /gdod naslhun grub rang char bas/ /byung ba lnga la rag ma pas/ /sku gsung thugs la rten mi cha/ /gsalbyed rig pai sgron ma yi s/ /gter khyim phung po gsal byed... / /longs sku dang nisprul pai sku/ /chu shel sgron mai dpes mtshon kyang/da lta rang la byung ma srid/ /khyung sgoma chag phur mi nus/.14 See TTT 54, p. 504, eigthth chapter of the Byang chub kyi sems rin chen khor lo: /sems nyid rigpai sgron ma yis...

Scheidegger, Daniel

2005-01-01T23:59:59.000Z

244

DOE Opens Investigation into Alleged Lighting Efficiency Violations |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Opens Investigation into Alleged Lighting Efficiency Violations Opens Investigation into Alleged Lighting Efficiency Violations DOE Opens Investigation into Alleged Lighting Efficiency Violations March 24, 2010 - 4:36pm Addthis Today, the U.S. Department of Energy announced it had issued subpoenas to three companies who were identified as selling certain torchiere lamps that failed to meet federal energy efficiency standards. Under the subpoenas, Target Corporation, Adesso, Inc. and Habitex Corporation are required to submit detailed information about the design of these products and how the companies marketed and sold them in the U.S. These investigations are part of the ongoing efforts at the Department of Energy and across the Obama Administration to strengthen and enforce federal energy efficiency standards that will save money for consumers and

245

Department of Energy Opens Investigation into Alleged Lighting Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Opens Investigation into Alleged Lighting Opens Investigation into Alleged Lighting Efficiency Violations Department of Energy Opens Investigation into Alleged Lighting Efficiency Violations March 24, 2010 - 12:00am Addthis WASHINGTON, DC - Today, the U.S. Department of Energy announced it had issued subpoenas to three companies who were identified as selling certain torchiere lamps that failed to meet federal energy efficiency standards. Under the subpoenas, Target Corporation, Adesso, Inc. and Habitex Corporation are required to submit detailed information about the design of these products and how the companies marketed and sold them in the U.S. These investigations are part of the ongoing efforts at the Department of Energy and across the Obama Administration to strengthen and enforce federal energy efficiency standards that will save money for consumers and

246

Development of a solar-desiccant dehumidifier. Phase II second technical progress report  

DOE Green Energy (OSTI)

The solar desiccant air conditioner (SODAC) system and its operation are described, including the characteristics of the major components, the performance at design conditions, and the control schemes for optimum operation in various climates. The system uses granular silica gel as a desiccant. It may operate in either a recirculated mode (no air exchange between the outside and the conditioned space) or a ventilated mode (air exchanged between outside and conditioned space). The test data in the ventilated mode at design flow rates are presented. Data include outdoor and indoor inlet wet and dry bulb temperatures, indoor outlet dry and wet bulb temperatures, capacity, coefficient of performance, air flow rates, hot water temperature, and solar heat used. The effects of indoor, outdoor, and hot water temperatures on the capacity and coefficient of performance are shown graphically, and the recirculated and ventilated modes, performances are compared. (LEW)

Rousseau, J.

1981-10-16T23:59:59.000Z

247

Development of a solar-desiccant dehumidifier. Phase II. Final summary report  

DOE Green Energy (OSTI)

The solar desiccant air conditioner (SODAC), its operation, characteristics of the major components, performance at design conditions, and the control schemes for optimum operation in various climates are described for both recirculated and ventilated configurations, with greater emphasis on the recirculated configuration. The development testing and the determination of the SODAC performance in both configurations over the entire range of interfacing parameters are reported. (LEW)

Rousseau, J.

1982-11-01T23:59:59.000Z

248

Experimental study of the heat and mass transfer in a packed bed liquid desiccant air dehumidifier  

Science Conference Proceedings (OSTI)

Desiccant cooling systems have the ability to provide efficient humidity and temperature control while reducing the electrical energy requirement for air conditioning as compared to a conventional system. Naturally, the desiccant air dehumidification process greatly influences the overall performance of the desiccant system. Therefore, the effects of variables such as air and desiccant flow rates, air temperature and humidity, desiccant temperature and concentration, and the area available for heat and mass transfer are of great interest. Due to the complexity of the dehumidification process, theoretical modeling relies heavily upon experimental studies. However, a limited number of experimental studies are reported in the literature. This paper presents results from a detailed experimental investigation of the heat and mass transfer between a liquid desiccant (triethylene glycol) and air in a packed bed absorption tower using high liquid flow rates. A high performance packing that combines good heat and mass transfer characteristics with low pressure drop is used. The rate of dehumidification, as well as the effectiveness of the dehumidification process are assessed based on the variables listed above. Good agreement is shown to exist between the experimental findings and predictions from finite difference modeling. In addition, a comparison between the findings in the present study and findings previously reported in the literature is made. The results obtained from this study make it possible to characterize the important variables which impact the system design.

Oeberg, V.; Goswami, D.Y. [Univ. of Florida, Gainesville, FL (United States)

1998-11-01T23:59:59.000Z

249

Dynamic performance of packed-bed dehumidifiers: experimental results from the SERI desiccant test loop  

DOE Green Energy (OSTI)

Discussed are the design and construction of a desiccant test loop and results of tests with a silica-gel-packed bed. The test loop consists of two centrifugal fans, two duct heaters, a steam humidifier, 24.4m (80 ft) of 30-cm (12-in.) circular duct, instrumentation, and a test section. The loop is capable of testing adsorption and desorption modes at flow rates up to 0.340 kg/s (600 scfm) and at regeneration temperatures up to 120/sup 0/C (248/sup 0/F). Tests of a 74-cm(29-in.)-diameter, 3.2-cm(1.25-in.)-thick silica gel bed indicated that mass transfer occurs more readily in the adsorption direction than in the desorption direction. Pressure drop data indicated that the resistance of each of the two screens that hold the silica gel in place was equivalent to 2.5-cm(1-in.) of silica gel due to plugging. Results of the tests were also used to validate a SERI desiccant computer model, DESSIM.

Kutscher, C F; Barlow, R S

1982-08-01T23:59:59.000Z

250

Development of a solar desiccant dehumidifier. Phase II. Technical progress report  

DOE Green Energy (OSTI)

The effort reported is a continuation of the development testing of the 1.5-ton solar desiccant air conditioner (SODAC) and is concerned with determination of the SODAC performance in the recirculated and ventilated mode configuration. Test data in the recirculated mode are presented. As originally conceived, the SODAC features two-speed indoor and outdoor fans to permit more efficient operation at reduced capacity. In both full-flow and half-flow cases, the experimental data are compared to computer predictions. The system and its operation are described, as are the system test facility and procedures. The system description includes the characteristics of the major components, the performance at design conditions, and the control schemes for optimum operation in various climates. (LEW)

Rousseau, J.

1981-03-27T23:59:59.000Z

251

Energy efficiency standards for residential and commercial equipment: Additional opportunities  

E-Print Network (OSTI)

Heating Refrigeration Air Conditioning Space Heating EnergyRefrigeration Air Conditioning Space Heating Savings inTorchiere Space heating Air conditioning Electric motors

Rosenquist, Greg; McNeil, Michael; Iyer, Maithili; Meyers, Steve; McMahon, Jim

2004-01-01T23:59:59.000Z

252

Energy efficiency standards for residential and commercial equipment: Additional opportunities  

E-Print Network (OSTI)

Torchiere Space heating Air conditioning Electric motorsCommercial Space heating Air conditioning Ventilation GasResidential End Use: Air conditioning Product: Room air

Rosenquist, Greg; McNeil, Michael; Iyer, Maithili; Meyers, Steve; McMahon, Jim

2004-01-01T23:59:59.000Z

253

Development of a multi-stage bubble column dehumidifier for application in a hymidification dehumidification desalination system  

E-Print Network (OSTI)

The Center for Clean Water and Clean Energy at MIT and KFUPM have been developing many novel desalination systems. One of the new technologies originating from the Lienhard Research Laboratory is the Humidification ...

Lam, Steven, S.B. Massachusetts Institute of Technology

2012-01-01T23:59:59.000Z

254

Buildings Energy Data Book: 2.1 Residential Sector Energy Consumption  

Buildings Energy Data Book (EERE)

6 6 Annual Cost Active Idle Off Active Idle Off ($) (2) Kitchen Coffee Maker 1,000 70 0 38 229 8,493 58 5.6 Dishwasher (3) 365 (4) 120 11.6 Microwave Oven 1,500 3 70 8,690 131 12.6 Toaster Oven 1,051 37 54 5.2 Refrigerator-Freezer 660 63.1 Freezer 470 45.0 Lighting 18-W Compact Fluorescent 18 1,189 20 2.1 60-W Incandescent Lamp 60 672 40 3.9 100-W Incandescent Lamp 100 672 70 6.4 Torchiere Lamp-Halogen 300 1,460 440 42.0 Bedroom and Bathroom Hair Dryer 710 50 40 3.4 Waterbed Heater 350 3,051 1,070 102.7 Laundry Room Clothes Dryer 359 (4) 1,000 96.0 Clothes Washer (3) 392 (4) 110 (3) 10.4 Home Electronics Desktop PCs 75 4 2 2,990 330 5,440 237 22.8 Notebook PCs 25 2 2 2,368 935 5,457 72 6.9 Desktop Computer Monitors 42 1 1 1,865 875 6,020 85 8.2 Stereo Systems 33 30 3 1,510 1,810 5,440 119 11.4 Televisions 97 4 1,860 6,900 222 (7) 21.3 Analog, <40" 86 1,095 (5) 184 17.7 Analog, >40"

255

Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings  

E-Print Network (OSTI)

Torchiere Source: [6]. Energy AC-DC Savings Conv.Effand fans unchanged Energy AC-DC Savings Conv.Eff Solar WaterFigure 10. Appliances energy savings versus direct-DC energy

Garbesi, Karina

2012-01-01T23:59:59.000Z

256

Advanced Lighting Program Development (BG9702800) Final Report  

E-Print Network (OSTI)

because CFL fixtures have much higher efficiencies than theenergy efficiency and longer life of the CFL. Despite thisCFL fixtures . This element aims to replace high-use fixtures (including halogen torchieres) with high-efficiency,

Rubinstein, Francis; Johnson, Steve

1998-01-01T23:59:59.000Z

257

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

in distribution transformers for power factor correction.of the power factors at the distribution transformers, or at

Gadgil, A.J.

2008-01-01T23:59:59.000Z

258

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

certain whether the electrical power is off or on, he may beof light. The electrical input (power, voltage and current)

Verderber, Rudy

2013-01-01T23:59:59.000Z

259

L Prize Competition Winner: 60W Incandescent Replacement Lamp  

NLE Websites -- All DOE Office Websites (Extended Search)

Prize Partners 14 15 Field Assessments: Retail Platte River Power Authority DTE Energy SMUD 16 Additional Opportunities: GATEWAY Demonstrations of LED Outdoor Lighting Reports...

260

NOPM and Availability of Framework Document for HID Lamps  

NLE Websites -- All DOE Office Websites (Extended Search)

8:48 Feb 27, 2012 8:48 Feb 27, 2012 Jkt 226001 PO 00000 Frm 00008 Fmt 4702 Sfmt 4702 E:\FR\FM\28FEP1.SGM 28FEP1 mstockstill on DSK4VPTVN1PROD with PROPOSALS Federal Register / Vol. 77, No. 39 / Tuesday, February 28, 2012 / Proposed Rules 11785 collections for particular program, except where required by statute. III. Questions for Comment The list below includes the questions about these reform ideas that address issues which are of greatest interest to OMB at this stage of the process. Comments addressing any other concerns, and other types of feedback, are also welcome. In addition, as was explained at the beginning of this notice, the public comments received by OMB will be posted on OMB's Web site and at http:// www.regulations.gov. Accordingly, please do not include in your comments

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

demonstration (like street lights) and commercialization andthe dominant light source for street and roadway lighting,has been a popular light source for street lighting because

Scholand, Michael

2012-01-01T23:59:59.000Z

262

Spectroscopy on Metal-Halide Lamps under Varying Gravity Conditions  

E-Print Network (OSTI)

orange street lighting), which has a slightly lower discharge conversion efficiency, but the 589 nm line. They are mainly used for applications where a high light output is desired; examples are shop lighting, street. Haverlag Copromotor: dr.ir. W.W. Stoffels Copyright c 2008 by A.J. Flikweert This research was financially

Eindhoven, Technische Universiteit

263

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

presents the national energy consumption profile for HIDVolume I: National Lighting Inventory and Energy Consumption

Scholand, Michael

2012-01-01T23:59:59.000Z

264

Ancient Lamps, Earrings Yield Their Secrets Under Neutron Imaging...  

NLE Websites -- All DOE Office Websites (Extended Search)

(3-D) neutron images have been taken of rare archaeological artifacts. Bronze and brass artifacts excavated at the ancient city of Petra, in present day Jordan, were recently...

265

Flash Lamp Curing of Printed Nano-Particle Films  

Science Conference Proceedings (OSTI)

About this Abstract. Meeting, Materials Science & Technology 2009. Symposium, Controlled Processing of Nanoparticle-Based Materials and Nanostructured...

266

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

representative electricity prices, because the residentialand 11. The range of electricity prices shown in the Figs.between mar- ginal electricity prices and residential tariff

Gadgil, A.J.

2008-01-01T23:59:59.000Z

267

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

and commercial electricity tariffs in each country. Noticemar- ginal electricity prices and residential tariff~. Anelectricity prices, because the residential tariff structure

Gadgil, A.J.

2008-01-01T23:59:59.000Z

268

Candelabra and Intermediate Base Lamps Enforcement Policy Statement  

Energy.gov (U.S. Department of Energy (DOE))

The Department issued guidance today advising manufacturers, importers and private labelers that DOE will not enforce the energy conservation standards and compliance certification requirements for...

269

The Therapeutic Lamp: Treating Small-Animal Phobias  

Science Conference Proceedings (OSTI)

We all have an irrational fear or two. Some of us get scared by an unexpected visit from a spider in our house; others get nervous when they look down from a high building. Fear is an evolutionary and adaptive function that can promote self-preservation ... Keywords: Animals,Medical treatment,Games,Visualization,Augmented reality,computer graphics,augmented reality,cockroach phobia,spider phobia,arachnophobia,anxiety,anxiety disorders,phobias,phobia therapy,psychological treatment

Maja Wrzesien, Mariano Alcaniz, Cristina Botella, Jean-Marie Burkhardt, Juana Breton-Lopez, Mario Ortega, Daniel Beneito Brotons

2013-01-01T23:59:59.000Z

270

Zero energy-storage ballast for compact fluorescent lamps  

DOE Patents (OSTI)

A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast. 4 figs.

Schultz, W.N.; Thomas, R.J.

1999-08-31T23:59:59.000Z

271

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

placed into light bulb sockets (Edison sockets) and the lampbe inserted into the same Edison type socket that is usedto injury. In addition, Edison sockets that are hori~

Verderber, Rudy

2013-01-01T23:59:59.000Z

272

Recycling of Fluorescent Lamp Glass into Clayey Ceramic  

Science Conference Proceedings (OSTI)

Designing a Collaborative System for Socio-Environmental Management of ... Oils Post-Consumption Residential and Commercial Clay with Two Brazilian.

273

iLamps: geometrically aware and self-configuring projectors  

Science Conference Proceedings (OSTI)

Projectors are currently undergoing a transformation as they evolve from static output devices to portable, environment-aware, communicating systems. An enhanced projector can determine and respond to the geometry of the display surface, and can be used ... Keywords: ad-hoc clusters, augmented reality, calibration, projector, quadric transfer, seamless display

Ramesh Raskar; Jeroen van Baar; Paul Beardsley; Thomas Willwacher; Srinivas Rao; Clifton Forlines

2005-07-01T23:59:59.000Z

274

iLamps: geometrically aware and self-configuring projectors  

Science Conference Proceedings (OSTI)

Projectors are currently undergoing a transformation as they evolve from static output devices to portable, environment-aware, communicating systems. An enhanced projector can determine and respond to the geometry of the display surface, and can be used ... Keywords: ad-hoc clusters, augmented reality, calibration, projector, quadric transfer, seamless display

Ramesh Raskar; Jeroen van Baar; Paul Beardsley; Thomas Willwacher; Srinivas Rao; Clifton Forlines

2006-07-01T23:59:59.000Z

275

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

1.7% of in- stalled hydroelectric capacity. Op. cit. ref [in Ig86) based on hydroelectric generation, and most of thethe still abundant hydroelectric potential of the country.

Gadgil, A.J.

2008-01-01T23:59:59.000Z

276

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

the functions of generation and distribution are separated,undertake generation, transmission, and distribution (e.g.paid by the distribution utility to the generation utility.

Gadgil, A.J.

2008-01-01T23:59:59.000Z

277

Stadiums and arenas use efficient, high wattage lamps - Today in ...  

U.S. Energy Information Administration (EIA)

Tools; Glossary All Reports ... weather; gasoline; capacity; exports; nuclear; forecast; View All Tags ...

278

Apparatus to facilitate lengthening the life of incandescent lamps  

SciTech Connect

An energizing circuit is described for an incandescent bulb comprising a transformer having a primary winding connectable to an AC mains source and first and second secondary windings for producing first and second voltages. The first secondary winding is connected to an input of a first full-wave rectifier means and the second secondary winding is connected to an input of a second full-wave rectifier means, the full-wave rectifier means having outputs connected in parallel across the bulb. The first voltage is sufficient to fully illuminate the bulb and the second voltage is sufficient to maintain the bulb warm but with little or no light output, a first switch being connected between the first secondary winding and the first rectifier means whereby, when the first switch is open, the bulb is energized solely by the second voltage.

Spissinger, F.H.

1987-03-17T23:59:59.000Z

279

L Prize Competition Winner 60W Incandesent Replacement Lamp Update  

NLE Websites -- All DOE Office Websites (Extended Search)

soon. --Senator Jeff Bingaman, D-NM What's the Buzz? - Would You Buy A 60 Light Bulb That Lasts 20 Years? -game-changing technology L Prize Helps Federal Purchasers:...

280

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

1988. The private sector in Brazil owned (in 1986) 40% ofElectricity Conservation in Brazil: Potential and Pro-electricity consumption in Brazil's residential sector was

Gadgil, A.J.

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Phosphor blends for high-CRI fluorescent lamps  

DOE Patents (OSTI)

A phosphor blend comprises at least two phosphors each selected from one of the groups of phosphors that absorb UV electromagnetic radiation and emit in a region of visible light. The phosphor blend can be applied to a discharge gas radiation source to produce light sources having high color rendering index. A phosphor blend is advantageously includes the phosphor (Tb,Y,LuLa,Gd).sub.x(Al,Ga).sub.yO.sub.12:Ce.sup.3+, wherein x is in the range from about 2.8 to and including 3 and y is in the range from about 4 to and including 5.

Setlur, Anant Achyut (Niskayuna, NY); Srivastava, Alok Mani (Niskayuna, NY); Comanzo, Holly Ann (Niskayuna, NY); Manivannan, Venkatesan (Clifton Park, NY); Beers, William Winder (Chesterland, OH); Toth, Katalin (Pomaz, HU); Balazs, Laszlo D. (Budapest, HU)

2008-06-24T23:59:59.000Z

282

Series Resonant Inverter with Contactless Transformers for Multiple LED Lamps.  

E-Print Network (OSTI)

??A half-bridge series-resonant inverter adopted to realize the quasi current source and the constant current source with a number of contactless transformers in series for (more)

Cheng, Shuen-Wen

2013-01-01T23:59:59.000Z

283

A Study on Electrodes for Capacitive Discharging UV Lamp  

Science Conference Proceedings (OSTI)

J10: Mechanical Properties and Welding Conditions of Monopile and Transition for Offshore Wind Plant J12: Microstructure and Mechanical Properties of...

284

Characterization of Fluorescent Lamp Glass Waste Powders for ...  

Science Conference Proceedings (OSTI)

The glass waste presents favorable characteristics for incorporation into clayey ceramic ... Codin, Located in Campos (RJ), to Produce Soil-Cement Blocks.

285

Zero energy-storage ballast for compact fluorescent lamps  

DOE Patents (OSTI)

A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast.

Schultz, William Newell (Niskayuna, NY); Thomas, Robert James (Rexford, NY)

1999-01-01T23:59:59.000Z

286

Electronic Fluorescent Lamp Ballasts Used in 4-Foot Fixtures  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the EPRI Power Electronics Applications Center (PEAC) Power Quality Test Facility to characterize ballast energy performance, emissions, and immunity from a PQ perspective.

2003-12-31T23:59:59.000Z

287

Miscellaneous electricity use in U.S. homes  

SciTech Connect

Historically, residential energy and carbon saving efforts have targeted conventional end uses such as water heating, lighting and refrigeration. The emergence of new household appliances has transformed energy use from a few large and easily identifiable end uses into a broad array of ''miscellaneous'' energy services. This group of so called miscellaneous appliances has been a major contributor to growth in electricity demand in the past two decades. We use industry shipment data, lifetimes, and wattage and usage estimates of over 90 individual products to construct a bottom-up end use model (1976-2010). The model is then used to analyze historical and forecasted growth trends, and to identify the largest individual products within the miscellaneous end use. We also use the end use model to identify and analyze policy priorities. Our forecast projects that over the period 1996 to 2010, miscellaneous consumption will increase 115 TWh, accounting for over 90 percent of future residential electricity growth. A large portion of this growth will be due to halogen torchiere lamps and consumer electronics, making these two components of miscellaneous electricity a particularly fertile area for efficiency programs. Approximately 20 percent (40 TWh) of residential miscellaneous electricity is ''leaking electricity'' or energy consumed by appliances when they are not performing their principal function. If the standby power of all appliances with a standby mode is reduced to one watt, the potential energy savings equal 21 TWh/yr, saving roughly $1-2 billion annually.

Sanchez, Marla C.; Koomey, Jonathan G.; Moezzi, Mithra M.; Meier, Alan; Huber, Wolfgang

1999-09-30T23:59:59.000Z

288

Supporting Equipment for Heating and Cooling Systems  

Energy.gov (U.S. Department of Energy (DOE))

Thermostats and ducts provide opportunities for saving energy. Dehumidifying heat pipes provide a way to help central air conditioners and heat pumps dehumidify air. Electric and gas meters allow users to track energy use.

289

Duquesne Light Company - Residential Energy Efficiency Program...  

Open Energy Info (EERE)

Central Air conditioners, Clothes Washers, Dehumidifiers, Dishwasher, Furnaces, Heat pumps, Lighting, Lighting ControlsSensors, Pool Pumps, Programmable Thermostats,...

290

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Submitting Public Comments The comment period is closed. Milestones and Documents The residential dehumidifiers energy conservation standards rulemaking docket...

291

Alexandria Light and Power - Residential Energy Efficiency Rebate...  

Open Energy Info (EERE)

Technologies Central Air conditioners, Clothes Washers, Dehumidifiers, Dishwasher, Energy Mgmt. SystemsBuilding Controls, Heat pumps, Lighting, Programmable Thermostats,...

292

Apartment and Condo New Construction Efficiency Services | Open...  

Open Energy Info (EERE)

Insulation, Central Air conditioners, Clothes Washers, Dehumidifiers, Dishwasher, Energy Mgmt. SystemsBuilding Controls, Equipment Insulation, Furnaces, Heat pumps, Heat...

293

Energy manager design for microgrids  

E-Print Network (OSTI)

equipment, absorption and adsorption cooling, desiccantabsorption chillers and desiccant dehumidifiers that use heat to reduce electrical cooling

Firestone, Ryan; Marnay, Chris

2005-01-01T23:59:59.000Z

294

L&E: Participate in a field test for high-efficiency troffer lighting. |  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting & Electrical » Participate Lighting & Electrical » Participate in a field test for high efficiency troffer lighting Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Participate in a field test for high-efficiency troffer lighting 50% of all commercial fluorescent lighting fixtures are recessed troffers in 1'x4', 2'x2' and 2'x4' configurations, in operation for more than 10 hours a day on average and collectively consuming more than 87 TWh of electricity annually. The Lighting & Electrical team supported the market introduction of high-efficiency troffers by developing a specification that allows for

295

L&E - high efficiency lighting for parking structure | The Better Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

structure structure Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt high-efficiency lighting for your parking structure Parking structures and garages are typically lighted by older HID lighting technology without any energy-saving controls. The latest high-efficiency alternatives with energy-saving controls-including light-emitting diode (LED), induction, and fluorescent technology options-can save building owners over 40% on their parking lot lighting bills while delivering additional benefits such as better-lighted spaces. The Lighting & Electrical team developed a performance specification that

296

L&E: Adopt high-efficiency lighting for your parking lot | The Better  

NLE Websites -- All DOE Office Websites (Extended Search)

lot lot Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt high-efficiency lighting for your parking lot Most parking lots are illuminated by older high-intensity discharge (HID) lighting technology without any energy-saving controls. New light-emitting diode (LED) technology can cut parking lot lighting energy bills by 40%, or much more with controls, while delivering additional benefits including long life, reduced maintenance costs, and improved lighting uniformity. The Lighting & Electrical team developed a performance specification to help building owners take advantage of these improved lighting

297

Side-by-Side Testing of Commercial Office Lighting Systems: Two-lamp Fluorescent Fixtures  

E-Print Network (OSTI)

Lighting systems in commercial office buildings are primary determinants of building energy use. In warmer climates, lighting energy use has important implications for building cooling loads as well as those directly associated with illumination tasks. To research the comparative performance of conventional and advanced office lighting systems, Florida Solar Energy Center (FSEC) set up the Lighting Flexible Test Facility (LFTF) which allows side-by-side comparison of lighting options in two otherwise identical 2.7 m x 3.7 m (9' x 12') south facing offices. The ceiling of the LFTF contains 0.61 m x 1.2 m (2' x 4') recessed fluorescent fixtures designed to be easily changed. Differing lighting systems were comparatively tested against each other over weeklong periods. Data on power consumption (watts), power quality (power factor), work-plane interior lighting levels (lux), bulb-wall, fixture and plenum temperatures were recorded every 15 minutes on a multi-channel data logger. This data allows realistic analysis of comparative lighting system performance including interactions with daylighting.

Parker, D. S.; Schrum, L.; Sonne, J. K.; Stedman, T. C.

1996-01-01T23:59:59.000Z

298

A high-efficiency indirect lighting system utilizing the solar 1000 sulfur lamp  

E-Print Network (OSTI)

and Renewable Energy, Office of Building Technology, State andand Renewable Energy, Office of Building Technology, State and

Siminovitch, Michael; Gould, C.; Page, E.

1997-01-01T23:59:59.000Z

299

L&E: Refrigerated Display Case | The Better Buildings Alliance  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting & Electrical » Adopt the Lighting & Electrical » Adopt the refrigerated display case lighting performance specification and start saving on your case lighting costs Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt the refrigerated display case lighting performance specification and start saving on your case lighting costs The LED Refrigerated Display Case Lighting Specification delivers nearly 50% energy savings compared to typical display case lighting. If all retail refrigerated display cases switched today to LED systems, over 2.1 TWh of electricity could be saved annually. LED Refrigerated Display Case Lighting Specification

300

Defining the Effectiveness of UV Lamps Installed in Circulating Air Ductwork  

SciTech Connect

Ultraviolet; UV; UVC; UVGI; HVAC; ductwork; mold; fungus; effectiveness; microbial; dose; irradiance; reflectance; bacillis; aspergillis

Douglas VanOsdell; Karin Foarde

2002-11-30T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

NIST Spectrum of Th-Ar Hollow Cathode Lamps in the 691 nm ...  

Science Conference Proceedings (OSTI)

... such as the Cryogenic High-Resolution IR Echelle Spectrograph ([CRIRES]), ESO's new IR spectrograph at the Very Large Telescope in Chile. ...

2011-12-13T23:59:59.000Z

302

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

E-Print Network (OSTI)

Green Lights Program to promote efficient lighting products through public education, consumer incentives, national product testing, and investments

Lin, Jiang

2002-01-01T23:59:59.000Z

303

Characterization of a high-gain picosecond flash-lamp-pumped Nd:YAG regenerative amplifier  

Science Conference Proceedings (OSTI)

We evaluate the performance of a novel 10-Hz picosecond Nd:YAG regenerative amplifier configured as a self-filtering unstable resonator. Pulse energies of approx.60 mJ in approx.100 psec at 1.06 ..mu..m are achieved using a single 6-mm-diameter Nd:YAG rod, while mode-matching requirements are minimized.

Dawson, M.D.; Schroeder, W.A.; Norwood, D.P.; Smirl, A.L.; Weston, J.; Ettelbrick, R.N.; Aubert, R.

1988-11-01T23:59:59.000Z

304

Contribution to the numerical study of turbulence in high intensity discharge lamps  

SciTech Connect

We present in this paper a comparison between results obtained with a laminar and turbulent models for high-pressure mercury arc. The two models are based on the resolution of bidimensional time-dependent equations by a semi-implicit finite-element code. The numerical computation of turbulent model is solved with large eddy simulation model; this approach takes into account the various scales of turbulence by a filtering method on each scale. The results show the quantitative influence of turbulence on the flow fields and also the difference between laminar and turbulent effects on the dynamic thermal behaviour and on the characteristics of the discharge.

Kaziz, S.; Ben Ahmed, R.; Helali, H.; Gazzah, H.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

2011-07-15T23:59:59.000Z

305

Whole Product Performance for 2X High-Efficiency Incandescent Lamps  

Science Conference Proceedings (OSTI)

FirstEnergy (FE) approached EPRIs Lighting Lab in 2011 to validate the performance of a newly developed 2X incandescent lighting technology developed by a manufacturing company in their service territory. This manufacturer claimed that their product was identical in light output, but twice (2X) as efficient as traditional 100W incandescent bulbs. In collaboration with FE, EPRI conducted a series of tests to independently verify the energy and photometric performance of this ...

2012-11-12T23:59:59.000Z

306

Tungsten Lamps as an Affordable Light Source for Testing of Photovoltaic Cells  

Science Conference Proceedings (OSTI)

An improved Tungsten light source system for photovoltaic cell testing made from low-cost, commercially available materials is presented as an alternative to standard expensive testing equipment. In this work, spectral correction of the Tungsten light ... Keywords: I-V measurement, Light source, Photovoltaic, Testing

Jeydmer Aristizabal; Badr Omrane; Clint Landrock; Sasan Vosoogh-Grayli; Yindar Chuo; Jasbir N. Patel; Bozena Kaminska; Carlo Menon

2011-06-01T23:59:59.000Z

307

RFIG lamps: interacting with a self-describing world via photosensing wireless tags and projectors  

Science Conference Proceedings (OSTI)

This paper describes how to instrument the physical world so that objects become self-describing, communicating their identity, geometry, and other information such as history or user annotation. The enabling technology is a wireless tag which acts as ... Keywords: augmented reality, human-machine communication, image stabilization, projector, radio frequency identification, stucture from motion

Ramesh Raskar; Paul Beardsley; Jeroen van Baar; Yao Wang; Paul Dietz; Johnny Lee; Darren Leigh; Thomas Willwacher

2004-08-01T23:59:59.000Z

308

DOE Requires Manufacturer and Labeler to Cease Sale of Incandescent Reflector Lamps  

Energy.gov (U.S. Department of Energy (DOE))

DOE has issued Notices of Non-Compliance Determination to Westinghouse Lighting Corporation and Fuzhou Sunlight Lighting Electrical Appliance Company requiring that they halt the sale of 8 basic...

309

Research on the Best Market Applications for LightLab Energy-Saving Lamps.  

E-Print Network (OSTI)

?? Nowadays, lighting represents 20% of the global electricity consumption. Light can be produced using different technologies but more than 100 years after its invention, (more)

Vilalta Cea, Raul

2010-01-01T23:59:59.000Z

310

Accurate modelling of Roman lamps in conimbriga using high dynamic range  

Science Conference Proceedings (OSTI)

The Human Visual System has a remarkable ability to acquire colour and contrast of all the things that surround us. This is particularly evident in extreme lighting conditions such as bright light or dark environments. However, it is simply not possible ...

A. Gonalves; L. Magalhes; J. Moura; A. Chalmers

2008-12-01T23:59:59.000Z

311

RFIG lamps: interacting with a self-describing world via photosensing wireless tags and projectors  

Science Conference Proceedings (OSTI)

This paper describes how to instrument the physical world so that objects become self-describing, communicating their identity, geometry, and other information such as history or user annotation. The enabling technology is a wireless tag which acts as ... Keywords: augmented reality, human-machine communication, image stabilization, projector, radio frequency identification, stucture from motion

Ramesh Raskar; Paul Beardsley; Jeroen van Baar; Yao Wang; Paul Dietz; Johnny Lee; Darren Leigh; Thomas Willwacher

2005-07-01T23:59:59.000Z

312

RFIG lamps: interacting with a self-describing world via photosensing wireless tags and projectors  

Science Conference Proceedings (OSTI)

This paper describes how to instrument the physical world so that objects become self-describing, communicating their identity, geometry, and other information such as history or user annotation. The enabling technology is a wireless tag which acts as ... Keywords: augmented reality, human-machine communication, image stabilization, projector, radio frequency identification, stucture from motion

Ramesh Raskar; Paul Beardsley; Jeroen van Baar; Yao Wang; Paul Dietz; Johnny Lee; Darren Leigh; Thomas Willwacher

2006-07-01T23:59:59.000Z

313

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry  

NLE Websites -- All DOE Office Websites (Extended Search)

News Latest News Videos Community Relations Past Projects Rebuilding Together Energy Teams Events Past Events For The Media Seminars Past Seminars Speakers Distinguished...

314

Lumen Maintenance Testing of the Philips 60-Watt Replacement Lamp L Prize Entry  

Science Conference Proceedings (OSTI)

This paper describes testing conducted to evaluate the Philips' L Prize award winning 60-watt LED replacement product's ability to meet the lifetime/lumen maintenance requirement of the competition, which was: "having 70 percent of the lumen value under subparagraph (A) [producing a luminous flux greater than 900 lumens] exceeding 25,000 hours under typical conditions expected in residential use." A custom test apparatus was designed and constructed for this testing and a statistical approach was developed for use in evaluating the test results. This will be the only publicly available, third-party data set of long-term LED product operation.

Gordon, Kelly L.; Hafen, Ryan P.; Hathaway, John E.; McCullough, Jeffrey J.

2012-09-01T23:59:59.000Z

315

LAMP-TR-108 NOVEMBER 2003 UMIACS-TR-2003-109  

E-Print Network (OSTI)

the right sorts of pages - Enter the Altavista search terms - Enter the words that identify sentences structure. Click Proceed to Search. Then enter the description "The ADJer the NP the ADJer the NP" and click to the LSE's My Collections screen. Paste or type the query you copied into the LSE's Altavista Search Terms

Gruner, Daniel S.

316

Phase II report on energy efficient electronic ballasts for a two-40 watt fluorescent lamp system  

SciTech Connect

The Department of Energy (DOE) has established a project aimed at accelerating the commercialization of electronic ballasts. During the Phase I portion of the project a small quantity of ballasts and other hardware were delivered for independent testing. Results verified the claims for energy savings and other unique and advantageous features of the electronic ballast. Phase II, a large scale field demonstration, is reported. The demonstration is being conducted by LBL and the Pacific Gas and Electric Company in the PG and E headquarters building in downtown San Fracisco. The test demonstration hardware is being procured. Included are two models of energy saving ballasts; two dimmer systems that show the potential for additional power savings; and, two models of Automatic Emergency Light Systems. Installation of ballasts and the beginning of actual test operations were originally scheduled for February 1978. However, slippages in hardware deliveries have caused a three-month delay. Testing at PG and E is now scheduled to begin in June 1978. Even though broad scale results from the Phase II demonstration at PG and E are not yet available, performance and versatility advantages of the electronic ballast have been demonstrated. They offer a clear incentive to the industry for development and production of reliable hardware that will be competitively saleable on a long term cost-of-lighting basis.

1978-07-01T23:59:59.000Z

317

Energy Basics: Incandescent Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

The three most common types of incandescent lamps are: Standard incandescent lamps Energy-Saving Incandescent (or Halogen) Reflector lamps Standard Incandescent Lamps Known as...

318

Incandescent Lighting | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

or pear-shaped A-19 lamps Energy-saving or halogen A-19 lamps Reflector or parabolic reflector (PAR) lamps, sometimes called "flood" or "spot" lamps Standard...

319

Over the past decade, lighting became more efficient across ...  

U.S. Energy Information Administration (EIA)

"Other" includes light-emitting diode (LED) lamps as well as other lamps such as fiber optic lights, induction lamps, and lamps of unknown ...

320

Baltimore Gas & Electric Company (Electric) - Residential Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

for Energy Star clothes washers, dehumidifiers, refrigerators, freezers, CFLs, HVAC systems, and Building Insulation. The Home Performance with Energy Star Incentive...

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Baltimore Gas and Electric Company (Electric) - Residential Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

for Energy Star clothes washers, dehumidifiers, refrigerators, freezers, CFLs, HVAC systems, and Building Insulation. The Home Performance with Energy Star Incentive...

322

Wakefield Municipal Gas & Light Department - Residential Conservation...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

include programmable thermostats, clothes washers, dishwashers, room and central AC units, dehumidifiers, and water heaters. All appliances must be Energy Star labeled , with...

323

| Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sears, Roebuck & Co. failed to certify two dehumidifiers as compliant with the applicable energy conservation standards. September 6, 2012 General Counsel Legal Interpretation...

324

Geography Department Safety HandbookSafety HandbookSafety HandbookSafety Handbook  

E-Print Network (OSTI)

.............................................................................................................211 7.1.2. Cooling Towers.2: Mechanical Forced-Draft Cooling Tower ........................................................214 Figure 7.........................................................................................267 Figure 8.10: Sprayed Coil Dehumidifier

Hickman, Mark

325

Overview: Home Cooling Systems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

than earlier models. Dehumidifying heat pipes can help an air conditioner remove humidity and more efficiently cool the air. Radiant Cooling Radiant cooling cools a floor or...

326

Engineered Solutions: Order (2010-CE-2112)  

Energy.gov (U.S. Department of Energy (DOE))

DOE issued an Order after entering into a Compromise Agreement with Engineered Solutions, Inc. to resolve a case involving the failure to certify dehumidifier basic model SD109.

327

Missouri River Energy Services (23 Member Cooperatives) - Residential...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Rebate Program Rebate Amount Ceiling Fan: 25 Clothes Washer: 50 Decorative Light String: 3.50string (6 string limit) Dehumidifier: 10 Dishwasher: 25 Refrigerator: 50...

328

Avista Utilities - Commercial Energy Efficiency Incentives Program...  

Open Energy Info (EERE)

Comprehensive MeasuresWhole Building, CustomOthers pending approval, Dehumidifiers, Energy Mgmt. SystemsBuilding Controls, Equipment Insulation, Lighting, Lighting Controls...

329

City of Palo Alto Utilities - Commercial Energy Efficiency Rebate...  

Open Energy Info (EERE)

MeasuresWhole Building, CustomOthers pending approval, Dehumidifiers, Dishwasher, Energy Mgmt. SystemsBuilding Controls, Equipment Insulation, Furnaces, Heat pumps,...

330

Georgia Environmental Finance Authority - Residential Energy...  

Open Energy Info (EERE)

Air conditioners, Clothes Washers, Dehumidifiers, Dishwasher, Doors, DuctAir sealing, Energy Mgmt. SystemsBuilding Controls, Furnaces, Heat pumps, Refrigerators, Water...

331

City of Plano - Smart Energy Loan Program (Texas) | Open Energy...  

Open Energy Info (EERE)

Washers, CustomOthers pending approval, Dehumidifiers, Dishwasher, DuctAir sealing, Energy Mgmt. SystemsBuilding Controls, Furnaces, Heat pumps, Lighting, Programmable...

332

Avista Utilities (Electric) - Commercial Energy Efficiency Incentives...  

Open Energy Info (EERE)

MeasuresWhole Building, CustomOthers pending approval, Dehumidifiers, Doors, Energy Mgmt. SystemsBuilding Controls, Equipment Insulation, Heat recovery, Motor VFDs,...

333

Renewable Energy and Energy Efficiency Project Financing (Illinois...  

Open Energy Info (EERE)

MeasuresWhole Building, CustomOthers pending approval, Dehumidifiers, Dishwasher, Energy Mgmt. SystemsBuilding Controls, Furnaces, Heat pumps, Lighting, Lighting Controls...

334

Avista Utilities (Electric) - Commercial Energy Efficiency Incentives...  

Open Energy Info (EERE)

MeasuresWhole Building, CustomOthers pending approval, Dehumidifiers, Doors, Energy Mgmt. SystemsBuilding Controls, Equipment Insulation, Heat recovery, Lighting,...

335

Energy Loan Fund | Open Energy Information  

Open Energy Info (EERE)

Chillers, Clothes Washers, CustomOthers pending approval, Dehumidifiers, Dishwasher, Energy Mgmt. SystemsBuilding Controls, Furnaces, Heat pumps, Lighting, Lighting Controls...

336

Cedar Falls Utilities - Commercial Energy Efficiency Rebate Program...  

Open Energy Info (EERE)

Clothes Washers, Compressed air, Dehumidifiers, Dishwasher, DuctAir sealing, Energy Mgmt. SystemsBuilding Controls, Furnaces, Heat pumps, Lighting, Lighting Controls...

337

2.1E Supplement  

E-Print Network (OSTI)

unit with dehumidifier and heat exchanger, with regenerationa dehumdifier plus heat exchanger, as in Mode 1, but withoutoutside air leaving the heat exchanger is exhausted and does

Winkelmann, F.C.

2010-01-01T23:59:59.000Z

338

Energy Basics: Supporting Equipment for Heating and Cooling Systems  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

for Heating and Cooling Systems Thermostats and ducts provide opportunities for saving energy. Dehumidifying heat pipes provide a way to help central air conditioners and heat...

339

Wellesley Municipal Light Plant - Residential Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Refrigerator: 100 Clothes Washing Machine: 75 Central AC: 100 Room AC Unit: 50 Dishwasher: 75 Dehumidifier: 50 Wellesley Municipal Light Plant (WMLP) offers a number of...

340

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Certain Consumer Products (Dishwashers, Dehumidifiers, Microwave Ovens, and Electric and Gas Kitchen Ranges and Ovens) http:energy.govnepadownloadsea-1662-final-environmental...

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Photonics in Industry: Water Disinfection and Contamination Treatment Dr. Gordon Knight  

E-Print Network (OSTI)

lamps, light emitting diodes, and flash lamps. Optimizing the irradiance and wavelength of the light

Czarnecki, Krzysztof

342

Status of Humidification DehumidificationStatus of Humidification Dehumidification Desalination  

E-Print Network (OSTI)

Heater Sea water in, w,i ,To Pure water, pw Carrier gas Packed bed Brine, b Humidifier Dehumidifier Solar Heater Sea water in, w,i ,To Pure water, pw Carrier gas Packed bed Brine, b 5 #12;DESALINATION consumption ­ HDH for larger scale water production ­ For reducing dehumidifier size/cost 6. Potential niche

Lienhard V, John H.

343

DOE Closes Investigation into Alleged Lighting Efficiency Violations |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Closes Investigation into Alleged Lighting Efficiency DOE Closes Investigation into Alleged Lighting Efficiency Violations DOE Closes Investigation into Alleged Lighting Efficiency Violations April 16, 2010 - 10:39am Addthis The U.S. Department of Energy has closed its investigation into the energy efficiency of lighting products manufactured by Habitex Corporation and sold under the Target and Adesso brand names based on test data provided by the companies. The Department requested information from the three companies last month in response to a complaint that these products did not meet the Department's energy efficiency standards for torchieres. Responding promptly to the Department's inquiry, the companies provided test data showing that these products did not meet the Energy Policy and Conservation Act's definition of torchiere and, as a result, did not

344

An interface to aid rural health workers in the preliminary diagnosis of cataract at the slit lamp using LOCS III  

Science Conference Proceedings (OSTI)

In India there is an inequitable distribution of wealth and resources; while 70% of population lives in villages, about 80 % of ophthalmologists practice in cities [4]. India has 1 ophthalmologist per 100,000 of its population [4] and this ratio is even ... Keywords: graphical user interfaces, healthcare, interaction styles, screen design, user-centered design

Satyendra Kumar Nainwal

2007-04-01T23:59:59.000Z

345

STATE OF UTAH CONTRACT NUMBER: MA049 October 06, 2010 Page 1 of 82 Includes Codale Lamp and Ballast  

E-Print Network (OSTI)

) = M0 EwMn Ewv (WT ) T-1 k=0 e- r (Wk, Wk+1) I (T n) Ewf (WT )2 exp (-T) T-1 k=0 r (Wk, Wk+1) I (T n) . Sending n and using monotone convergence we obtain that v (w) / Ewf (WT )2 exp (-T) T-1 k=0 r

Capecchi, Mario R.

346

Solid-state semiconductors are better alternatives to arc-lamps for efficient and uniform illumination in minimal access surgery  

E-Print Network (OSTI)

of technical and ergonomic limitations. White light-emitting diodes (LEDs) are energy-efficient solid- state Illumination Á Light-emitting diode Á Minimal access surgery Á Solid-state semiconductor In the 1950s

Rosso, Lula

347

Demonstration Assessment of Light-Emitting Diode (LED) Retrofit Lamps at Intercontinental Hotel in San Francisco, CA  

SciTech Connect

This document is a report of observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy (DOE) GATEWAY Demonstration Program. The program supports demonstrations of high-performance solid-state lighting (SSL) products in order to develop empirical data and experience with in-the-field applications of this advanced lighting technology. The DOE GATEWAY Demonstration Program focuses on providing a source of independent, third-party data for use in decision-making by lighting users and professionals; this data should be considered in combination with other information relevant to the particular site and application under examination. Each GATEWAY Demonstration compares SSL products against the incumbent technologies used in that location. Depending on available information and circumstances, the SSL product may also be compared to alternate lighting technologies. Though products demonstrated in the GATEWAY program have been prescreened and tested to verify their actual performance, DOE does not endorse any commercial product or in any way guarantee that users will achieve the same results through use of these products.

Miller, Naomi J.; Curry, Ku'Uipo J.

2010-11-01T23:59:59.000Z

348

Demonstration Assessment of Light-Emitting Diode (LED) Retrofit Lamps at the Lobby of the Bonneville Power Administration, Portland, OR  

SciTech Connect

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in the lobby of the Bonneville Power Administration (BPA) headquarters building in Portland, Oregon. The project involved a simple retrofit of 32 track lights used to illuminate historical black-and-white photos and printed color posters from the 1930s and 1940s. BPA is a federal power marketing agency in the Northwestern United States, and selected this prominent location to demonstrate energy efficient light-emitting diode (LED) retrofit options that not only can reduce the electric bill for their customers but also provide attractive alternatives to conventional products, in this case accent lighting for BPA's historical artwork.

Miller, Naomi

2011-07-01T23:59:59.000Z

349

The LAMP-like protein p67 plays an essential role in the lysosome of African trypanosomes  

E-Print Network (OSTI)

: ( ) ( ) ( ) ( ) U c U x U U x p p c x + = d dcw w Note that because U is a function of S, in general

Sheridan, Jennifer

350

Visible Light Digital Camera --Up to 2.3MP resolution with LED lamps provides sharp images  

E-Print Network (OSTI)

regardless of lighting conditions · Fusion Picture in Picture (PIP) -- Displays thermal image super Marker Function · Auto Hot/Cold spot marker function shows a spot within the area that automatically finds the hottest or coldest spot within the box i-Series Features FLIR i60 -- Scalable Fusion picture

Short, Daniel

351

Analysis, design and optimization of the LCC resonant inverter as a high-intensity discharge lamp ballast  

SciTech Connect

A complete study of the clamped-mode (CM) series-parallel (LCC) resonant inverter together with some of the control-to-output characteristics are presented in this paper. Also, a new control method for the CM LCC resonant inverter is introduced. With this method, the inverter is forced to operate with optimum commutations and without handling reactive energy, thus minimizing both switching and conduction losses. The corresponding design procedure is illustrated with a design example. Finally, some experimental results obtained from a prototype at the laboratory are also shown to validate the analysis and evaluate the proposed control method.

Alonso, J.M.; Blanco, C.; Lopez, E.; Calleja, A.J.; Rico, M. [Univ. de Oviedo, Gijon (Spain). Dept. de Ingenieria Electrica y Electronica

1998-05-01T23:59:59.000Z

352

Energy-efficient H. I. D. solid-state ballast: Phase II final report. [150 watt high pressure sodium lamp  

SciTech Connect

The following report presents the results of Phase II, Development of Solid State 150 watt High Pressure Sodium Ballasts. Basically, the objectives of the development program were accomplished, i.e., greater than 90% efficiency, greater than 90% power factor, regulation equivalent to ferro-magnetic ballasts, and energy savings sufficient to warrant the further development of the solid-state HPS ballast for commercial production and marketing. 8 figs., 5 tabs.

1983-06-01T23:59:59.000Z

353

Appliance Standard Program - The FY 2003 Priority -Setting Summary...  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent Lamp Ballasts Electric Motors, 1-200HP Fluorescent Lamps Commercial Oil- and Gas-Fired Packaged Boilers Mobile Home Furnaces High-Intensity Discharge Lamps...

354

Section 5.4.1 Linear Fluorescent Lighting: Greening Federal Facilities...  

NLE Websites -- All DOE Office Websites (Extended Search)

and color temperature. When specifying a lighting sys- tem, be sure that the lamp and ballast are electrically matched and the lamp and fixture optically matched. Fluorescent lamp...

355

Analysis of advanced solar hybrid desiccant cooling systems for buildings  

DOE Green Energy (OSTI)

This report describes an assessment of the energy savings possible from developing hybrid desiccant/vapor-compression air conditioning systems. Recent advances in dehumidifier design for solar desiccant cooling systems have resulted in a dehumidifier with a low pressure drop and high efficiency in heat and mass transfer. A recent study on hybrid desiccant/vapor compression systems showed a 30%-80% savings in resource energy when compared with the best conventional systems with vapor compression. A system consisting of a dehumidifier with vapor compression subsystems in series was found to be the simplest and best overall performer.

Schlepp, D.; Schultz, K.

1984-10-01T23:59:59.000Z

356

Analysis of a direct radiation solar dehumidification system  

DOE Green Energy (OSTI)

SERI researchers investigated a desiccant dehumidifier that is regenerated by direct absorption of solar radiation using a simplified numerical model (DESSIM) of the adsorption and desorption processes. This paper presents estimates of the performance of a solar-fired air conditioning system (ventilation cycle) containing the dehumidifier/collector. The researchers also considered the effects of dehumidifier NTUs, heat exchanger performance, and insolation levels. The direct radiation system can operate effectively at low insolation levels and thus may have some advantages in some geographic areas.

Schultz, K.; Barlow, R.; Pesaran, A.; Kreith, F.

1985-06-01T23:59:59.000Z

357

DTE Energy (Gas) - Residential Energy Efficiency Program | Open...  

Open Energy Info (EERE)

Refrigerator Recycling: 40 Clothes Washer: 25 - 50 Dehumidifier and AC Recycling: 20 Home Energy Audit: Up to 75 Furnace: Up to 500 Furnace Tune-up: 50 Boiler: 1000 -...

358

Haier: ENERGY STAR Referral (DE45EK) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ENERGY STAR Referral (DE45EK) Haier: ENERGY STAR Referral (DE45EK) May 10, 2013 DOE referred the matter of Haier-brand dehumidifier, model DE45EK, to the U.S. Environmental...

359

Danby: ENERGY STAR Referral (DDR7009REE) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DDR7009REE) Danby: ENERGY STAR Referral (DDR7009REE) May 10, 2013 DOE referred the matter of Danby-brand dehumidifier, model DDR7009REE, to the U.S. Environmental Protection...

360

Edgestar: ENERGY STAR Referral (DEP400EW) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Edgestar: ENERGY STAR Referral (DEP400EW) Edgestar: ENERGY STAR Referral (DEP400EW) June 7, 2013 DOE referred the matter of Edgestar-brand dehumidifier, model DEP400EW, to the U.S....

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Kenmore: ENERGY STAR Referral (90701) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

90701) Kenmore: ENERGY STAR Referral (90701) May 10, 2013 DOE referred the matter of Kenmore-brand dehumidifier, model number 90701, to the U.S. Environmental Protection Agency,...

362

Energy effectiveness of simultaneous heat and mass exchange devices  

E-Print Network (OSTI)

Simultaneous heat and mass exchange devices such as cooling towers, humidifiers and dehumidifiers are widely used in the power generation, desalination, air conditioning, and refrigeration industries. For design and rating ...

Narayan, G. Prakash

2010-01-01T23:59:59.000Z

363

Design of an axial turbine and thermodynamic analysis and testing of a K03 turbocharger  

E-Print Network (OSTI)

A novel humidification dehumidification desalination system was developed at the Rohseneow Kendall Heat Transfer Laboratory. The HDH system runs by having different pressures in the humidifier and dehumidifier. One of the ...

Perez Zuiga, Yoshio Samaizu

2011-01-01T23:59:59.000Z

364

DOE Solar Decathlon: Product Directory  

NLE Websites -- All DOE Office Websites (Extended Search)

Fixed Lighting Plug-In Lighting MechanicalHVAC Air-to-Air Heat Pump Air-to-Water Heat Pump Absorption chiller Ceiling Fans Centralized Ventilation Systems Dehumidifier...

365

Radiant Cooling | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

be kept dehumidified. In humid climates, simply opening a door could allow enough humidity into the home to allow condensation to occur. The panels cover most of the ceiling,...

366

Whole-House Ventilation | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

into the house to be filtered to remove pollen and dust or dehumidified to provide humidity control Supply ventilation systems work best in hot or mixed climates. Because they...

367

Review of Desiccant Dehumidification Technology  

DOE Green Energy (OSTI)

This paper overviews applications of desiccant technology for dehumidifying commercial and institutional buildings. Because of various market, policy, and regulatory factors, this technology is especially attractive for dehumidification applications in the I990s.

Pesaran, A. A.

1994-10-01T23:59:59.000Z

368

Million U.S. Housing Units Total U.S...........................  

Gasoline and Diesel Fuel Update (EIA)

... 25.8 23.7 22.1 0.6 Q Q 0.6 Auto BlockEngineBattery Heater... 0.8 0.7 0.7 N Q N Q Electric Dehumidifier......

369

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Dishwashers, Dehumidifiers, and Conventional Cooking Products Standby Mode and Off Mode Test Procedure Dishwashers, Dehumidifiers, and Conventional Cooking Products Standby Mode and Off Mode Test Procedure Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is amending its test procedures for residential dishwashers, dehumidifiers, and conventional cooking products (kitchen ranges and ovens) to provide for measurement of standby mode and off mode energy use by these products. This activity is mandated by the Energy Policy and Conservation Act (EPCA). This Rulemaking is related to the Residential Dishwashers and Residential Dehumidifiers Standard and Test Procedure. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information

370

Evaluating the Impact of the  

E-Print Network (OSTI)

simulated using linear fluorescent lamps with correlated color temperatures of 5000K. Yet, the variability among linear fluorescent lamp systems, which include the lamp, ballast and reflector, is great Linear Fluorescent Lamps Fluorescent lamps are produced in many different forms. Linear fluorescent lamps

Zanibbi, Richard

371

Testing and design of solar cooling systems employing liquid dessicants  

DOE Green Energy (OSTI)

An open cycle liquid desiccant cooling system with cooling capacity of 3 tons (10.5 kW) a subject of research at Colorado State University. The system comprises two main units: the dehumidifier and the regenerator. Lithium bromide is the desiccant solution that dehumidifies the air stream during a counter-current, liquid-gas contacting in the packed tower. The regenerator concentrates the lithium bromide solution during a similar gas-liquid contacting using solar heated air with the only difference being that the direction of heat and mass transfer are reversed in this unit. The earlier studies conducted on the dehumidifier revealed significant departures from an energy balance closure. An attempt has been made to provide a realistic energy balance closure to the dehumidifier side. This has resulted in substantial re-calibration of the major instruments involved. Performance data of the entire system with the regenerator and dehumidifier operated in coupled mode have been presented. An optimization scheme to predict operating conditions suited for best performance of the two units, for varying ambient temperature and humidity to the dehumidifier, has been devised. 15 refs., 20 figs., 8 tabs.

Lenz, T.; Loef, G.O.G.; Flaherty, M.; Misra, S.; Patnaik, S.

1989-05-01T23:59:59.000Z

372

AEP Ohio (Gas) - Residential Energy Efficiency Rebate Program | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

(Gas) - Residential Energy Efficiency Rebate Program (Gas) - Residential Energy Efficiency Rebate Program AEP Ohio (Gas) - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Cooling Commercial Heating & Cooling Other Appliances & Electronics Sealing Your Home Ventilation Heat Pumps Commercial Lighting Lighting Manufacturing Windows, Doors, & Skylights Program Info State Ohio Program Type Utility Rebate Program Rebate Amount ENERGY STAR New Homes Program: Contact AEP Ohio In-home Energy Audit: $75 Pin Based CFL Indoor Fixture: $20 Pin Based CFL Outdoor Fixture: $35 CFL Torchieres: $20 Wall Insulation: $75 Air Sealing: $50 Window Film: $45 ENERGY STAR Window Replacement: $75 Attic Insulation: $90 Shower Start/Stop: $25

373

Mechanistic Evaluation of the Pros and Cons of Digital RT-LAMP for HIV1 Viral Load Quantification on a Microfluidic Device and  

E-Print Network (OSTI)

. We learned the following three lessons from this work: (i) digital amplification technologies with HIV, many of whom live in developing countries and under resource-limited conditions.1 As antire- troviral treatment becomes more widely available, viral resistance to first-line antiretroviral drugs

Ismagilov, Rustem F.

374

The effect of the operation modes of a gas discharge low-pressure amalgam lamp on the intensity of generation of 185 nm UV vacuum radiation  

SciTech Connect

The effect of the discharge current, mercury vapor pressure, and the inert gas pressure on the intensity and efficiency of the 185 nm line generation are considered. The spectra of the UV radiation (vacuum ultraviolet) transmission by protective coatings from the oxides of rare earth metals and aluminum are investigated.

Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru [Russian Academy of Sciences, Joint Institute of High Temperatures (Russian Federation); Drozdov, L. A., E-mail: lit@npo.lit.ru; Kostyuchenko, S. V.; Sokolov, D. V. [ZAO LIT (Russian Federation); Kudryavtsev, N. N.; Sobur, D. A., E-mail: soburda@gmail.com [Moscow Institute for Physics and Technology (Russian Federation)

2011-12-15T23:59:59.000Z

375

All products of the future clothes, household devices, lamps will contain electronic units. Graduates in Electronic Design Engineering will be able  

E-Print Network (OSTI)

to design the software and elec- tronics of the future, design energy-friendly systems by using clean tech. Graduates in Electronic Design Engineering will be able to design both electronics and system software hardware and software electronics, as well as mathematics and physics, to prototype cutting-edge projects

376

Assessment of Electrical, Efficiency, and Photometric Performance of Advanced Lighting Sources: Dimmable Advanced Lighting Technolog ies -- Electronic Light-Emitting Diode (LED) Fixtures, Lamps, and Drivers  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses the dimming performance of light-emitting diode (LED) lighting. Chapter 1 provides a discussion of basic lighting control, the importance of considering power quality in lighting control, lighting control methods and parameters, and the advantages and future of lighting control. Chapter 2 addresses in more depth the dimming methods used in advanced lighting sources and controls for incandescent, fluorescent, high-intensity discharge (HID) and LED sources. Chapter 3 ad...

2008-12-19T23:59:59.000Z

377

1995-2011 | LS-LAMP IMPACT REPORT uniVersity of neW orLeAns | new orleans, la  

E-Print Network (OSTI)

.S., mathematics, michigan State University, East Lansing, mI m.S., Statistical Science, Baylor University, waco was the second place winner of the 2010 Joint statistical meetings (Jsm) stat Bowl. she was also named oustanding Graduate stu- dent (2010) by Baylor university's Department of statistical sciences. she has also

Kulp, Mark

378

Advanced Light Sources  

Science Conference Proceedings (OSTI)

In the generation of artificial light using electric lamps, photometric and color performance have been paramount in lamp design, manufacturing, measurement, lighting design, and visual perception. Many designers and researchers have strived to understand how light and color are generated, related, and to improve them. This has stemmed from the development of incandescent lamps, halogen lamps, linear fluorescent lamps, high-intensity discharge (HID) lamps, and compact fluorescent lamps (CFLs) among other...

2008-03-31T23:59:59.000Z

379

Desiccant contamination research: Report on the desiccant contamination test facility  

DOE Green Energy (OSTI)

The activity in the cooling systems research involves research on high performance dehumidifiers and chillers that can operate efficiently with the variable thermal outputs and delivery temperatures associated with solar collectors. It also includes work on advanced passive cooling techniques. This report describes the work conducted to improve the durability of solid desiccant dehumidifiers by investigating the causes of degradation of desiccant materials from airborne contaminants and thermal cycling. The performance of a dehumidifier strongly depends on the physical properties and durability of the desiccant material. To make durable and reliable dehumidifiers, an understanding is needed of how and to what degree the performance of a dehumidifier is affected by desiccant degradation. This report, an account of work under Cooling Systems Research, documents the efforts to design and fabricate a test facility to investigate desiccant contamination based on industry and academia recommendations. It also discusses the experimental techniques needed for obtaining high-quality data and presents plans for next year. Researchers of the Mechanical and Industrial Technology Division performed this work at the Solar Energy Research Institute in FY 1988 for DOE's Office of Solar Heat Technologies. 7 refs., 19 figs., 1 tab.

Pesaran, A.A.; Bingham, C.E.

1991-07-01T23:59:59.000Z

380

Desiccant contamination research: Report on the desiccant contamination test facility  

SciTech Connect

The activity in the cooling systems research involves research on high performance dehumidifiers and chillers that can operate efficiently with the variable thermal outputs and delivery temperatures associated with solar collectors. It also includes work on advanced passive cooling techniques. This report describes the work conducted to improve the durability of solid desiccant dehumidifiers by investigating the causes of degradation of desiccant materials from airborne contaminants and thermal cycling. The performance of a dehumidifier strongly depends on the physical properties and durability of the desiccant material. To make durable and reliable dehumidifiers, an understanding is needed of how and to what degree the performance of a dehumidifier is affected by desiccant degradation. This report, an account of work under Cooling Systems Research, documents the efforts to design and fabricate a test facility to investigate desiccant contamination based on industry and academia recommendations. It also discusses the experimental techniques needed for obtaining high-quality data and presents plans for next year. Researchers of the Mechanical and Industrial Technology Division performed this work at the Solar Energy Research Institute in FY 1988 for DOE's Office of Solar Heat Technologies. 7 refs., 19 figs., 1 tab.

Pesaran, A.A.; Bingham, C.E.

1991-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens  

SciTech Connect

This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

Not Available

1993-11-01T23:59:59.000Z

382

Pre-clinical Measures of Eye Damage (Lens Opacity), Case-control Study of Tuberculosis, and Indicators of Indoor Air Pollution from Biomass Smoke  

E-Print Network (OSTI)

for cooking and heating, and promotion of solar lamps orheating fuel used Main source of light in the house Electricity Kerosene lamp Solarsolar lamps. Key words: biomass fuel, cooking-fuel smoke, heating,

Pokhrel, Amod Kumar

2010-01-01T23:59:59.000Z

383

ComEd - Business Instant Lighting Discounts Program (Illinois...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

lamps include screw-in CFLs, reduced wattage T8 and T5 linear fluorescents, screw-in LED lamps and LED trim kits and reduced wattage ceramic metal halide lamps. All incentives...

384

Barron Electric Cooperative - Energy Star Appliance & Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Terminal Heat Pump: 150ton CFL: 1 -5 Per Lamp CFL Fixtures-Hardwired: 5 Per Unit LED Lamp (least 5 watts): 2 Per Lamp LED Security Lighting: 15 Per Fixture Occupancy...

385

Browse wiki | Open Energy Information  

Open Energy Info (EERE)

for each lighting unit will be computed as: Lamps rated cpacity per lamp including Ballast X 0.097pacity per lamp including Ballast X 0.097 OpenEIUtilityRate...

386

BEFORE THE U.S. DEPARTMENT OF ENERGY  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Engineered Solutions, Inc. 1 Case Number: 20 10-CE-2 1 12 Engineered Solutions, Inc. 1 Case Number: 20 10-CE-2 1 12 (Dehumidifiers) 1 1 NOTICE OF PROPOSED CIVIL PENALTY Date issued: September 8,2010 Number of alleged violations: 2 Maximum possible assessment: $51,382 Proposed civil penalty: $14,600 The Office of the General Counsel of the U.S. Department of Energy (DOE) alleges that Engineered Solutions, Inc. violated certain provisions of the Energy Policy and Conservation Act, 42 U.S.C. fj 6201 et seq., 10 C.F.R. Part 430, or both. Specifically, DOE alleges: 1. Engineered Solutions, Inc. is a manufacturer (importer) of dehumidifiers, including model SD 109. 2. Model ~ ~ 1 0 9 has been in distribution in the U.S. for at least nine months. 3. The dehumidifier referenced in paragraph 1 is a "covered product" as defined by

387

BEFORE THE U.S. DEPARTMENT OF ENERGY  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

General Electric Appliances ) Case Number: 201 0-CE-2 1 13 General Electric Appliances ) Case Number: 201 0-CE-2 1 13 (Dehumidifiers) ) 1 NOTICE OF PROPOSED CIVIL PENALTY Date issued: September 8,201 0 Number of alleged violations: 5 Maximum possible assessment: $252,140 Proposed civil penalty: $36,500 The Office of the General Counsel of the U.S. Department of Energy (DOE) alleges that General Electric Appliances (GE) violated certain provisions of the Energy Policy and Conservation Act, 42 U.S.C. 6201 et seq., 10 C.F.R. Part 430, or both. Specifically, DOE alleges: 1. GE manufactures or privately labels a variety of dehumidifiers, including models ADER30LN; ADER40LN; ADERSOLN; and ADER65LN. 2. These models have been in distribution in the U.S. for at least 365 days. 3. The dehumidifiers referenced in paragraph 1 are "covered products" as defined by

388

Overview of developing programs in solar desiccant cooling for residential buildings  

DOE Green Energy (OSTI)

An overview is provided of the ongoing work in desiccant cooling under the national solar heating and cooling research program. Open cycle adsorption and absorption systems are examined. The different dehumidifier bed configurations are the distinguishing features of these systems. The basic operating principles of each dehumidifier concept are explained along with some discussion of their comparative features. Performance predictions developed by SERI for a solar desiccant solar system employing an axial-flow desiccant wheel dehumidifier are presented. In terms of life-cycle cost and displaced fossil-fuel energy, the results indicate that it should be beneficial to use solar desiccant coolers in residential applications. Although no prototype testing of any of these concepts is currently underway, test results are expected and will be reported within one year.

Not Available

1979-01-01T23:59:59.000Z

389

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

have been required to comply with the Department of Energy (DOE) energy conservation standards for fluorescent lamp ballasts since 1990. Fluorescent lamp ballasts control electric...

390

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2011  

E-Print Network (OSTI)

The Effect of Efficiency Standards on Water Use and Water1989. Lamp Efficiency Standards for Massachusetts: AnalysisNational Efficiency Standards for Lamps, Motors, Showerheads

Meyers, Stephen

2013-01-01T23:59:59.000Z

391

ON-SITE DEMONSTRATION PROCEDURE FOR SOLID-STATE FLUORESCENT BALLAST  

E-Print Network (OSTI)

state ballast supplies electrical power to the lamp at acan transform the input electrical power to the lamp morethe measurement of electrical power, voltage, and current if

Verderber, Rudy

2013-01-01T23:59:59.000Z

392

EA-1881: Energy Conservation Program: Energy Conservation Standards...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts EA-1881: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp...

393

Browse wiki | Open Energy Information  

Open Energy Info (EERE)

of energy-saving Compact Fluorescent Light Bulbs + , solar-powered lights + , LED bulbs + , auto lamps and other speciality lamps. + , Nanhai + , Guangdong Province + ,...

394

Glossary - U.S. Energy Information Administration (EIA)  

U.S. Energy Information Administration (EIA)

Included in this category are the familiar screw-in light bulbs, as well as somewhat more efficient lamps, such as tungsten halogen lamps, reflector ...

395

SSL Roadmap  

NLE Websites -- All DOE Office Websites (Extended Search)

new jobs. For the most part, LEDs will displace point sources such as incandescent lamps (light- bulbs), while OLEDs will displace area sources such as fluorescent lamps. OLEDs...

396

Federal Energy Management Program: Federal Procurement of Energy...  

NLE Websites -- All DOE Office Websites (Extended Search)

industrial luminaires and many types of exterior lighting. ENERGY STAR covers light bulbs, including compact fluorescent lamps and LED lamps, and light fixtures, including a...

397

Catalog of DC Appliances and Power Systems  

E-Print Network (OSTI)

AC LEDs, particularly for lower luminosity bulbs. Efficacy (bulb or tube, a compact fluorescent lamp typically includes an integral ballast, as do HID lamps, and an LED

Garbesi, Karina

2012-01-01T23:59:59.000Z

398

Energy Basics: Fluorescent Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

& Cooling Water Heating Fluorescent Lighting Fluorescent lamps use 25%-35% of the energy used by incandescent lamps to provide the same amount of illumination (efficacy of...

399

NIST Global Standards Information Europe  

Science Conference Proceedings (OSTI)

... and electronic household and office equipment; set-top-boxes; electric motors; wet-rotor pumps; directional lamps, light emitting diode lamps and ...

400

xml version="1.0" encoding="UTF-8"?>  

Science Conference Proceedings (OSTI)

... and electronic household and office equipment; set-top-boxes; electric motors; wet-rotor pumps; directional lamps, light emitting diode lamps and ...

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

NIST Global Standards Information Switzerland  

Science Conference Proceedings (OSTI)

... and electronic household and office equipment; set-top-boxes; electric motors; wet-rotor pumps; directional lamps, light emitting diode lamps and ...

402

Federal Energy Management Program: Federal Energy Efficiency...  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent Tube Lamps FEMP temporarily suspended its energy efficiency requirements for fluorescent tube lamps as it evaluates the market impact of the pending 2012 minimum...

403

U.S. Energy Information Administration (EIA) - Sector  

Annual Energy Outlook 2012 (EIA)

incandescent bulbs. High-performance incandescent, compact fluorescent, and light-emitting diode (LED) lamps continue to replace low-efficacy incandescent lamps. In 2035,...

404

NIST: Atomic Spectroscopy Group - Optogalvanic Reference ...  

Science Conference Proceedings (OSTI)

... Changes in the lamp current that occur when a resonance is achieved are detected by a drop in voltage across the lamp's ballast resistor with a lock ...

2010-10-05T23:59:59.000Z

405

Residential Energy Efficiency Rebate Programs | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Energy Efficiency Rebate Programs Residential Energy Efficiency Rebate Programs Residential Energy Efficiency Rebate Programs < Back Eligibility Residential Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Clothes Washers: $40-$75 Dehumidifiers: $25 Refrigerators: $50 Pool pumps: $200 Provider Efficiency Vermont Efficiency Vermont provides financial incentives for its residential customers to install energy efficient equipment in their homes. Eligible Energy Star equipment includes dehumidifiers (seasonal rebates), refrigerators, clothes washers, and swimming pool pumps. The website provides details on eligible makes and models as well as rebate application

406

EA-1662: Final Environmental Assessment | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

62: Final Environmental Assessment 62: Final Environmental Assessment EA-1662: Final Environmental Assessment 10 CFR Part 430 Energy Conservation Program: EnergyConservation Standards for Certain Consumer Products (Dishwashers, Dehumidifiers, Microwave Ovens, and Electric and Gas Kitchen Ranges and Ovens) This chapter describes potential environmental effects that may result from amended energy conservation standards for residential cooking products and commercial clothes washers. Environmental Assessment for 10 CFR Part 430 Energy Conservation Program: Energy Conservation Standards for Certain Consumer Products (Dishwashers, Dehumidifiers, Microwave Ovens, and Electric and Gas Kitchen Ranges and Ovens) and for Certain Commercial and Industrial Equipment (Commercial Clothes Washers), DOE/EA-1662 (April 2009)

407

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High-Intensity Discharge Lamps High-Intensity Discharge Lamps Sign up for e-mail updates on regulations for this and other products There are currently no energy conservation standards for high-intensity discharge (HID) lamps. HID lamps are electric discharge lamps and include high-pressure sodium, mercury vapor, and metal halide lamps. HID lamps require an HID ballast to start and regulate electric current flow through the lamp. HID lamps are used in street and roadway lighting, area lighting such as for parking lots and plazas, industrial and commercial building interior lighting, security lighting for commercial, industrial, and residential spaces, and landscape lighting. The Standards and Test Procedures for this product are related to Rulemaking for High Intensity Discharge Lamps Energy Conservation Standard and Rulemaking for High Intensity Discharge Lamps Test Procedures.

408

Acoustic features of song categories and their possible implications for communication in the common  

E-Print Network (OSTI)

; redwing, Turdus iliacus, Lampe & Espmark, 1987). Furthermore, playback experiments in several species have

Amrhein, Valentin

409

Preface In recent decades we have witnessed the enormous impact of scientific computing  

E-Print Network (OSTI)

, furniture, lamps, small appliances, curtains, dishes, and more Moon Zoom 813 Pacific Avenue, Santa Cruz 831

Buscaglia, Gustavo C.

410

1.0. Semiconductor Diodes 1 of 27 1.2 Ideal Diode  

E-Print Network (OSTI)

-high efficiency light emitting diode lamps. As an educational institution, DTCC has shown a serious commitment

Allen, Gale

411

GREEN BUILDING GUIDELINES UNIVERSITY OF MASSACHUSETTS AMHERST  

E-Print Network (OSTI)

Engineers (CIBSE) with an average lamp output 55% of the maximum [8]. Proprietary granular lighting control

Massachusetts at Amherst, University of

412

SCHOOl OF THE BUIlT ENVIRONmENT 35128 Undergraduate Prospectus `10  

E-Print Network (OSTI)

recommended by the Char- tered Institution of Building Services Engineers (CIBSE) with an average lamp output

Singer, Jeremy

413

J. Fluid Mech. (2001), vol. 426, pp. 355386. Printed in the United Kingdom c 2001 Cambridge University Press  

E-Print Network (OSTI)

Engineers (CIBSE) with an average lamp output 55% of the maximum [8]. Proprietary granular lighting control

Linden, Paul F.

414

Arnold Schwarzenegger LIGHTING RESEARCH PROGRAM  

E-Print Network (OSTI)

fluorescent task lamp. The prototype used commercially available materials: 1watt light emitting diodes to the mounting board. Development of LightEmitting Diode Task Lamp using Advanced Technologies: Prototype 2 lightemitting diode task lamp. The problem of developing an energy efficient light emitting diode task lamp

415

EA-1881: Finding of No Significant Impact  

Energy.gov (U.S. Department of Energy (DOE))

Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts (October 2011)

416

EA-1881: Final Environmental Assessment  

Energy.gov (U.S. Department of Energy (DOE))

Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts (October 2011)

417

www.ornl.gov Environmental Chambers at ORNL  

E-Print Network (OSTI)

-air HVAC system, heat pump water heaters, a dehumidifying water heater, solid-state lighting, hybrid solar for testing appliances such as residential water heaters and refrigerators. · Two large two-room, side temperature cycles to test heat pump/AC equipment under quasi- field conditions. #12;www.ornl.gov Water Heater

Oak Ridge National Laboratory

418

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Dehumidifiers Dehumidifiers Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of residential dehumidifiers since 2007. Residential dehumidifiers reduce the level of humidity-the amount of water vapor-in the air. The standard mandatory in 2007 will save approximately 0.27 quads of energy and result in approximately $3.14 billion in energy bill savings for products shipped from 2007-2031. The standard will avoid about 14.1 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 2.8 million automobiles. The standard mandatory in 2012 will save approximately 0.3 quads of energy and result in approximately $4.7 billion in energy bill savings for products shipped from 2012-2036. The standard will avoid about 15.6 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 3.1 million automobiles.

419

Performance of the SERI parallel-passage dehumidifer  

DOE Green Energy (OSTI)

The key component in improving the performance of solar desiccant cooling systems is the dehumidifier. A parallel-passage geometry for the desiccant dehumidifier has been identified as meeting key criteria of low pressure drop, high mass transfer efficiency, and compact size. An experimental program to build and test a small-scale prototype of this design was undertaken in FY 1982, and the results are presented in this report. Computer models to predict the adsorption/desorption behavior of desiccant dehumidifiers were updated to take into account the geometry of the bed and predict potential system performance using the new component design. The parallel-passage design proved to have high mass transfer effectiveness and low pressure drop over a wide range of test conditions typical of desiccant cooling system operation. The prototype dehumidifier averaged 93% effectiveness at pressure drops of less than 50 Pa at design point conditions. Predictions of system performance using models validated with the experimental data indicate that system thermal coefficients of performance (COPs) of 1.0 to 1.2 and electrical COPs above 8.5 are possible using this design.

Schlepp, D.; Barlow, R.

1984-09-01T23:59:59.000Z

420

Total U.S......................................................  

U.S. Energy Information Administration (EIA) Indexed Site

... 25.8 2.8 5.8 5.5 3.8 7.9 1.4 5.1 Auto BlockEngineBattery Heater... 0.8 Q 0.2 Q Q 0.3 Q Q Electric Dehumidifier......

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

" Million U.S. Housing Units"  

U.S. Energy Information Administration (EIA) Indexed Site

3,12.3,9.7,0.5,0.6,0.7,0.8 "4 or More",25.8,23.8,0.7,0.5,"Q",0.6 "Auto BlockEngineBattery Heater",0.8,0.7,"Q","Q","N","Q" "Electric Dehumidifier",13.3,11.7,0.8,0.5,0.3,"Q"...

422

New Lighting Technologies  

Science Conference Proceedings (OSTI)

This Electric Power Research Institute (EPRI) technical update continues the technical assessment of advanced lighting technologies in the following product areaslinear LED T8 fluorescent replacements, Edison-based dimmable LED lamps, commercial replacement side-lit LED fixtures, Edison-based reduced-consumption halogen lamps designed to replace 100W incandescent lamps, high bay induction LED lamps, and architectural LED lamps. Many of the products in this years report are designed as ...

2012-10-08T23:59:59.000Z

423

Flicker Performance of Modern Lighting Technologies including Impacts of Dimmers  

Science Conference Proceedings (OSTI)

The existing industry standards on flicker measurement and assessment are based on the response of general purpose incandescent lamps. However, worldwide these lamps are being replaced with more energy efficient lamps including Compact Fluorescent Lamps (CFLs) and Light emitting Diode (LED) lamps. In order to keep the flicker standards relevant, the industry standard bodies on the subject are in need of the evidence that compares the flicker performance of new lighting ...

2012-12-12T23:59:59.000Z

424

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81 - 17290 of 26,764 results. 81 - 17290 of 26,764 results. Download Renewables Portfolio Standards: What Are We Learning? http://energy.gov/oe/downloads/renewables-portfolio-standards-what-are-we-learning Download CX-008000: Categorical Exclusion Determination Crystal Chemistry of Toxic Metal Sequestration CX(s) Applied: B3.6 Date: 02/09/2012 Location(s): Illinois Offices(s): Science, Chicago Office http://energy.gov/nepa/downloads/cx-008000-categorical-exclusion-determination Download Target: Subpoena (2010-SE-2001) DOE issued a Subpoena for Information and Production of Documents to Target Corporation requesting information regarding the compliance of various torchieres Target has distributed in commerce in the U.S. http://energy.gov/gc/downloads/target-subpoena-2010-se-2001 Rebate Forestry Policies (Kentucky)

425

AEP Ohio (Electric) - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

AEP Ohio (Electric) - Residential Energy Efficiency Rebate Program AEP Ohio (Electric) - Residential Energy Efficiency Rebate Program AEP Ohio (Electric) - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Cooling Commercial Heating & Cooling Other Sealing Your Home Ventilation Heat Pumps Appliances & Electronics Commercial Lighting Lighting Manufacturing Windows, Doors, & Skylights Program Info State Ohio Program Type Utility Rebate Program Rebate Amount ENERGY STAR New Homes Program: Contact AEP In-home Energy Audit: $100 Pin Based CFL Indoor Fixture: $20 Pin Based CFL-Outdoor Fixture: $35 CFL Torchieres: $20 Wall Insulation: $200 Air Sealing: $200 ENERGY STAR Window Replacement: $200 Attic Insulation: $200 Shower Start/Stop: $25

426

Adesso Inc. U.S. DEPARTMENT OF ENERGY 1000 INDEPENDENCE A VE., SW  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Adesso Inc. Adesso Inc. U.S. DEPARTMENT OF ENERGY 1000 INDEPENDENCE A VE., SW WASHINGTON, DC 20585 ) ) ) SUBPOENA Case Number: 2010-SE-2002 FOR INFORMATION AND PRODUCTION OF DOCUMENTS To: Margaret Traub, CEO Adesso Inc. 21 Penn Plaza Suite 909 New York, NY 10001 Issued: March 23, 2010 Service by certified mail The U.S. Department of Energy (DOE) issues this Subpoena for Information and Production of Documents to Adesso Inc. (Adesso) pursuant to 42 U.S.C. § 6299 of the Energy Policy and Conservation Act (EPCA) and the regulations promulgated thereunder (10 C.F.R. § 430. 72). As you should be aware, pursuant to EPCA, DOE has established an energy conservation standard applicable to torchieres. See 42 U.S.C. § 6295(x); 10 CFR 430.32(t). Manufacturers and private

427

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology  

SciTech Connect

The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

Not Available

1993-11-01T23:59:59.000Z

428

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Certain Lamps Exempted from General Service Incandescent Lamp Standards Certain Lamps Exempted from General Service Incandescent Lamp Standards Sign up for e-mail updates on regulations for this and other products The information on this page pertains to the Department of Energy's (DOE) analysis of and unit sales forecast for five lamp types, which was mandated by the Energy Independence and Security Act of 2007 (EISA 2007). Among the requirements of subtitle B of title III of EISA 2007 were provisions directing DOE to evaluate and publish within 1 year a benchmark unit sales estimate for five types of incandescent lamps (rough service lamps, vibration service lamps, 3-way incandescent lamps, 2,601-3,300 lumen general service incandescent lamps, and shatter-resistant lamps). These lamp types were not made subject to the regulatory standards for general service incandescent lamps established by EISA 2007. Among the requirements of subtitle B of title III of EISA 2007 were provisions directing DOE to collect, analyze, and monitor unit sales of these five lamp types.

429

EA-1664: Final Environmental Assessment | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

64: Final Environmental Assessment 64: Final Environmental Assessment EA-1664: Final Environmental Assessment 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps The U.S. Department of Energy has determined that the adoption of energy conservation standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps as described in the final rule titled the "energy Conservation Program: Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector lamps," would not be a major federal action significantly affecting the quality of the human environment. Environmental Assessment for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps,

430

Federal Energy Management Program: Energy Cost Calculator for Compact  

NLE Websites -- All DOE Office Websites (Extended Search)

Compact Fluorescent Lamps to someone by E-mail Compact Fluorescent Lamps to someone by E-mail Share Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Facebook Tweet about Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Twitter Bookmark Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Google Bookmark Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Delicious Rank Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Digg Find More places to share Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on AddThis.com... Energy-Efficient Products Federal Requirements Covered Product Categories

431

Find cost-effective investments | ENERGY STAR Buildings & Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

lamps and can save 10 per sign annually in electricity costs. Swap out incandescent light bulbs with ENERGY STAR certified CFLs or LEDs in your desk, task, and floor lamps....

432

Building Technologies Office: Solid-State Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

of two pages from the CALiPER Snapshot Report on A lamps. CALiPER Product Snapshot on LED Light Bulbs Report on the current state of the market for LED A lamp and omnidirectional...

433

PHASE I FINAL REPORT SUBCONTRACT NO. 2019702 "ENERGY EFFICIENT FLUORESCENT BALLASTS"  

E-Print Network (OSTI)

Stabilize ballast at 235 volts input AC for 60 seconds withI Sec. (Lamp) E Cathode Ckt Volt: Yel Dum. Load Full. L.O.Factor Same lamps used = Watts/Volt-Amps, Approx. accuracy +

Authors, Various

2011-01-01T23:59:59.000Z

434

Illuminated Diagrams: Using Light and Print to Comparative Advantage W. Bradford Paley  

E-Print Network (OSTI)

the representation of information. Raskar's "Shader Lamps," e.g. [4] project onto dioramas to add textures; G. Welch, K-L Low, D. Bandyopadhyay, "Shader Lamps: Animating Real Objects with Image Based

Indiana University

435

May 1999 POV-Ray 3.1g User Documentation Page 1 Persistence of Vision TM Ray-Tracer  

E-Print Network (OSTI)

existing wall and desk surfaces to expand the area of the traditional computer interface. With Shader Lamps. Bandyopadhyay, "Shader lamps: Animating real objects with image-based illumination," in Rendering Techniques

Sherrill, David

436

In Support of Leadership: Robitaille  

E-Print Network (OSTI)

2004), pages 165­172, June 2004. 2 [2] D. Bandyopadhyay, R. Raskar, and H. Fuchs. Dynamic shader lamps. Bandyopadhyay. Shader lamps: Animating real objects with image-based illu- mination. In Rendering Techniques

de Lijser, Peter

437

Journal of Biopharmaceutical Statistics, 19: 641657, 2009 Copyright Taylor & Francis Group, LLC  

E-Print Network (OSTI)

existing wall and desk surfaces to expand the area of the traditional computer interface. With Shader Lamps. Bandyopadhyay, "Shader lamps: Animating real objects with image-based illumination," in Rendering Techniques

Qin, Zhaohui Steve

438

Commercialization-Analysis-&-Roadmap-  

indicated!in!note!13!is!$232.!!Total!energy!cost!=!$2000.!We!used!the!$19!cost!for!30W!germicidal! lamps!from!asltg.com,!although!lamps!were!36!W.!! [17] ...

439

Federal Energy Management Program: Energy Cost Calculator for...  

NLE Websites -- All DOE Office Websites (Extended Search)

8000 hours Number of lamps in retrofit project Hours operating per week hours Average cost of electricity 0.06 kWh Relamper labor costs hr Time taken to retrofit all lamps...

440

Building Technologies Program - 1995 Annual Report  

E-Print Network (OSTI)

CFL fixture achieves the highest fixture efficiency byCFL, and a 22-watt Circline fluorescent lamp, with fixture efficienciesCFL rather than the typical A-Lamp have the possibility of significantly in- creasing fixture efficiency

Selkowitz, S.E.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Solid-State Lighting on a Shoestring Budget: The Economics of Off-Grid Lighting for Small Businesses in Kenya  

E-Print Network (OSTI)

to Charge a 1200 mAh Battery Cost per LED Lamp Charge (Ksh/battery powered LED lamps introduced to the businesses and the costbattery charging services, while solar charging did not involve any ongoing costs.

Radecsky, Kristen

2009-01-01T23:59:59.000Z

442

Energy Basics: Fluorescent Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Fluorescent Lighting Fluorescent lamps use 25%-35% of the energy used by incandescent lamps to provide the same amount of illumination (efficacy of 30-110 lumens per watt). They...

443

Solid-State Lighting: LED Replacements for Linear Fluorescent...  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Replacements for Linear Fluorescent Lamps Webcast to someone by E-mail Share Solid-State Lighting: LED Replacements for Linear Fluorescent Lamps Webcast on Facebook Tweet about...

444

LBNL-5364E  

NLE Websites -- All DOE Office Websites (Extended Search)

as do HID lamps, and an LED lamp includes electronic driver and optics) LED light-emitting diode ix lumen a measure of the power of light perceived by the human eye microgrid A...

445

DOE Solar Decathlon: 2009 Building Industry Workshops  

NLE Websites -- All DOE Office Websites (Extended Search)

workshop addresses an array of energy-efficient lighting options, focusing on light-emitting diode (LED) lamps and compact fluorescent lamps. (PDF 3.7 MB) LEED for Homes: Green...

446

Energy Efficiency Standards and Labels in North America: Opportunities for Harmonization  

E-Print Network (OSTI)

L mc ,S m L ve ** ,S m Dishwashers L mc ,L ve ,S m L mc ,LClothes washers Clothes washers and dryers DishwashersDishwashers Fluorescent lamp ballasts Fluorescent lamp

Wiel, Stephen

2008-01-01T23:59:59.000Z

447

Baltimore Gas & Electric Company (Electric) - Commercial Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lamps: 25 - 30 Lighting Occupancy Sensors: 25-75unit T8T5 Fluorescent Lamp-Ballast: 15-65fixture Fluorescent High-Bay Fixtures: 40 - 85fixture Hard-Wired CFL:...

448

Fluorescent fixtures and ballasts  

SciTech Connect

The basic parameters of a fluorescent lighting system that affect the illumination level are discussed. The parameters include the thermal performance of the fixture and the ballast factor, voltage regulation, and thermal regulation of the ballast/lamp system. Fixtures determine the minimum lamp-wall temperature of the lamps and are described as hot or cold. That is, the lamp-wall temperatures can vary from 39 to 61/sup 0/C. In general, cool fixtures tend to provide higher light levels and are more efficacious for a given ballast/lamp system. Solid-state fluorescent ballast/lamp systems have been measured and show a variation in light output from 6170 to 3780 lumens for the two-lamp, F-40, T-12, rapid-start lamps. Lighting designers must obtain this information in order to accurately predict illumination levels in a space.

Verderber, R.R.

1984-05-01T23:59:59.000Z

449

Browse wiki | Open Energy Information  

Open Energy Info (EERE)

dusk till daylight. Price of lamp per month: (Rated kW capacity of lamp, including ballast x 4000 x 0.0741)12p, including ballast x 4000 x 0.0741)12 OpenEIUtilityRate...

450

Section 5.4.3 Compact Fluorescent Lighting: Greening Federal...  

NLE Websites -- All DOE Office Websites (Extended Search)

2.7 m), wall-wash- ers, and decorative pendants. Retrofit lamps that contain the lamp, ballast, and screw base all in one unit are widely available. As a rule, however, these units...

451

NIST Highlight about spectrally tunable lighting facility  

Science Conference Proceedings (OSTI)

... white light produced by fluorescent lamps? Which spectral combination gives the best color quality and energy efficiency? ...

2012-10-02T23:59:59.000Z

452

(SAN DIEGO ASSOCIATION OF GOVERNMENTS)  

E-Print Network (OSTI)

, or Light Emitting Diode. The lamps were also classified by location in the house, wattage, hardwired vs

453

No Slide Title  

Science Conference Proceedings (OSTI)

... 85 Customers, 400 Lamps George Westinghouse and Nikola Tesla Thomas Edison and Joseph Swan Power Distribution Options -- Battle ...

2012-07-24T23:59:59.000Z

454

Energy Efficiency Indicators Methodology Booklet  

E-Print Network (OSTI)

Kerosene lamp Wood Stove Biogas Stove Charcoal Stove CoalDistrict heating Wood Biogas Charcoal Stove/ Room Coal

Sathaye, Jayant

2010-01-01T23:59:59.000Z

455

RoHS  

Science Conference Proceedings (OSTI)

... Cat 4. Consumer electronics: TVs, DVD players, stereos, video cameras; Cat 5. Lighting: lamps, lighting fixtures, light bulbs; ...

456

After-hours power status of office equipment and energy use of miscellaneous plug-load equipment  

E-Print Network (OSTI)

industrial refrigerator, S freezer incandescent tracklight, 50 lamps each phone/PBX centrex system coffee maker, residential model microwave oven

Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Margaret; Busch, John F.

2004-01-01T23:59:59.000Z

457

UNDERWRITERS' LABORATORIES, INC.  

Science Conference Proceedings (OSTI)

... Key Words - Arrhenius Law, Light Emitting Diode, Light Degradation Rate, Photoelectric ... Light Emitting DiOde (LED) Source Lamps (2) ...

2009-05-05T23:59:59.000Z

458

Advanced Lighting Technologies  

Science Conference Proceedings (OSTI)

This report continues the technical assessment of advanced lighting technologies in the following product areasdimmable light-emitting diode (LED) screw-in replacement lamp, hybrid compact fluorescent lamp/halogen screw-in replacement lamp, replacement recessed can LED downlight, organic LED (OLED) disc, replacement mini high-intensity discharge (HID) lamp and ballast system, and solid-state plasma lighting (miniature HID technology) high-bay fixture. The research in this project helps to demonstrate how...

2011-12-21T23:59:59.000Z

459

OE Summary 2005-14  

NLE Websites -- All DOE Office Websites (Extended Search)

power lines ...1 * Improper modification results in electric arc that shatters lamp lens ... 6 * Good Practice: Use of safety belt...

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Characteristics and Applications of Copper Stamp Sand  

Science Conference Proceedings (OSTI)

The chemical, physical properties and antimicrobial activity of stamp sand were investigated, ... Characterization of Fluorescent Lamp Glass Waste Powders for...

462

BEFORE THE U.S. DEPARTMENT OF ENERGY  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sylvane, Inc. Sylvane, Inc. (dehumidifiers) ) ) ) ) ) Case Number: 2013-CE-36005 NOTICE OF PROPOSED CIVIL PENALTY Date issued: October 16, 2013 Number of alleged violations: 400 (2 basic models; 200 days) Maximum possible assessment: $80,000 Proposed civil penalty: $8,000 The U.S. Department of Energy ("DOE") Office of the General Counsel, Office of Enforcement, alleges that Sylvane, Inc. ("Sylvane") has violated certain provisions of the Energy Policy and Conservation Act, 42 U.S.C. § 6291 et seq. ("the Act"), and 10 C.F.R. § 429.12. Specifically, DOE alleges: 1. Sylvane has manufactured 1 at least two dehumidifier basic models under the PrimeAire brand: PA5010E and PA7010E. 2. Since at least March 31, 2013, Sylvane has distributed, and continues to distribute, basic

463

Heating and Cooling System Support Equipment Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heating and Cooling System Support Equipment Basics Heating and Cooling System Support Equipment Basics Heating and Cooling System Support Equipment Basics July 30, 2013 - 3:28pm Addthis Thermostats and ducts provide opportunities for saving energy. Dehumidifying heat pipes provide a way to help central air conditioners and heat pumps dehumidify air. Electric and gas meters allow users to track energy use. Thermostats Programmable thermostats can store and repeat multiple daily settings. Users can adjust the times heating or air-conditioning is activated according to a pre-set schedule. Visit the Energy Saver website for more information about thermostats and control systems in homes. Ducts Efficient and well-designed duct systems distribute air properly throughout a building, without leaking, to keep all rooms at a comfortable

464

BEFORE THE US. DEPARTMENT OF ENERGY  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

US. DEPARTMENT OF ENERGY US. DEPARTMENT OF ENERGY Washington, D.C. 20585 In the Matter of 1 Basement Systems, Inc. ) ) Case Number: 20 10-CE-2110 (Dehumidifiers) ) 1 NOTICE OF PROPOSED CIVIL PENALTY Date issued: September 8,2010 Number of alleged violations: 2 Maximum possible assessment: $68,510 Proposed civil penalty: $14,600 The Office of the General Counsel of the U.S. Department of Energy (DOE) alleges that Basement Systems, Inc. violated certain provisions of the Energy Policy and Conservation Act, 42 U.S.C. $ 620 1 et seq., 10 C.F.R. Part 430, or both. Specifically, DOE alleges: 1. Basement Systems, Inc. privately labels under its Sanidry label a variety of dehumidifiers, including model SD109, which is imported by Engineered Solutions, Inc. 2. Model SD109 has been in distribution in the U.S. for at least 365 days.

465

U.S. Department of Energy Categorical Exclusion Determination Form  

NLE Websites -- All DOE Office Websites (Extended Search)

Pro-iectTitle: (0289-1530) ADMA Products, Inc. - Pro-iectTitle: (0289-1530) ADMA Products, Inc. - High-Efficiency,on-line MembraneAir Dehumidifier Location: *- Multiple States - OH, WA, TX ProposedAction or Project Description: American Recovery and Reinvestment Act: Funding will support laboratory and bench-scale research and development on a novel air dehumidifier equipped with a highly effective porous metal membrane. The proposed work is consistent with the goal of BEETIT: the development of energy efficient cooling technologies and air conditioners for buildings, to save energy and reduce GHG emissions. Proposed work consists entirely of RD&D work to be completed in ADMA's facilities in Hudson, OH; Pacific Northwest National Laboratory's dedicated labs in Richland, WA; and laboratory facilities on Texas A&M1scampus in College Station, TX. All work to be performed will be limited to

466

De'Longhi USA, Inc.  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

De'Longhi USA, Inc. De'Longhi USA, Inc. (Dehumidifiers) BEFORE THE U.S. DEPARTMENT OF ENERGY Washington, D.C. 20585 ) 1 ) Case Number: 20 10-CE-2114 ) ) NOTICE OF PROPOSED CIVIL PENALTY Date issued: September 8,2010 Number of alleged violations: 13 Maximum possible assessment: $741,820 Proposed civil penalty: $94,900 The Office of the General Counsel of the U.S. Department of Energy (DOE) alleges that De'Longhi USA, Inc. (DeyLonghi) violated certain provisions of the Energy Policy and Conservation Act, 42 U.S.C. $ 6201 et seq., 10 C.F.R. Part 430, or both. Specifically, DOE alleges: 1. DeyLonghi manufactures or privately labels a variety of dehumidifiers, including, models DD40P, DD45, DD45P, DDSOP, DE400, DE400P, DE500, DESOOP, DE650P, DENSOOP, DG50, and DW30M.

467

Frequently Asked Questions | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Frequently Asked Questions Frequently Asked Questions Frequently Asked Questions November 1, 2013 - 11:40am Addthis Frequently asked questions (FAQs) and their corresponding answers regarding industrial distributed energy (DE) and combined heat and power (CHP) are provided below. What is CHP? Why is there so much interest in CHP? Is CHP the same as cogeneration? What is the difference between CHP, CCHP, BCHP, DER, IES? Why can't I use my backup generator for on-site power production? Backup generators have been around for decades, what is new about on-site power generation? What types of power generators can I buy? How are generators classified, what is a kW? What is a recuperator and why is it important? What is an HRSG? What is a desiccant dehumidifier? How do desiccant dehumidifiers use waste heat in a CHP system?

468

High performance solar desiccant cooling system: performance evaluations and research recommendations  

DOE Green Energy (OSTI)

This report presents an assessment of the current status of solar desiccant cooling and makes recommendations for continued research to develop high performance systems competitive with conventional cooling systems. Solid desiccant, liquid desiccant, and hybrid systems combining desiccant dehumidifiers with vapor compressor units are considered. Currently, all desiccant systems fall somewhat short of being competitive with conventional systems. Hybrid systems appear to have the greatest potential in the short term. Solid systems are close to meeting performance goals. Development of high performance solid desiccant dehumidifiers based on parallel passage designs should be pursued. Liquid system collector/generators and efficient absorbers should receive attention. Model development is also indicated. Continued development by hybrid systems is directly tied to the above work.

Schlepp, D.R.; Schultz, K.J.

1984-09-01T23:59:59.000Z

469

Preliminary study of the potential for performance improvements in solar desiccant cooling  

DOE Green Energy (OSTI)

The basic operation of the desiccant cooling system is reviewed, and a preliminary evaluation of the potential for improving desiccant cooling system performance to COPs of 1.0 to 1.2 is performed. A second-law thermodynamic system analysis was carried out, demonstrating that present desiccant systems only achieve 10% to 15% of theoretical maximum performance and that a large potential for improvement exists. Computer simulations have been used to study the effects of improving desiccant properties and increasing the effectiveness of some components of the system. Results have shown that modification of desiccant properties can only produce a limited (10%) increase in COP. Larger increases can be achieved by increasing the effectiveness of the sensible heat exchanger. However, this study indicates that the key to obtaining higher COPs is in the design of the dehumidifier. One design that shows promise is the parallel passage dehumidifier.

Schlepp, D.R.; Barlow, R.

1981-10-01T23:59:59.000Z

470

Improving Gas-Fired Heat Pump Capacity and Performance by Adding a Desiccant Dehumidification Subsystem  

E-Print Network (OSTI)

This paper examines the merits of coupling a desiccant dehumidification subsystem to a gas-engine- driven vapor compression air conditioner. A system is identified that uses a rotary, silica gel, parallel-plate dehumidifier. Dehumidifier data and analysis are based on recent tests. The dehumidification subsystem processes the fresh air portion and handles the latent portion of the load. Adding the desiccant subsystem increases the gas-based coefficient of performance 40% and increases the cooling capacity 50%. Increased initial manufacturing costs are estimated at around $500/ton ($142/kW) for volume production. This cost Level is expected to reduce the total initial cost per ton compared to a system without the desiccant subsystem.

Parsons, B. K.; Pesaran, A. A.; Bharathan, D.; Shelpuk, B. C.

1990-01-01T23:59:59.000Z

471

Overview of Open-Cycle Desiccant Cooling Systems and Materials  

DOE Green Energy (OSTI)

This paper has presented a review of the thermodynamics of three desiccant cooling cycles: the ventilation cycle, the recirculation cycle, and the Dunkle cycle. For the ventilation cycle the qualitative effects of changes in the effectiveness of individual components were analyzed. There are two possible paths to improved dehumidifier performance: changing the design of dehumidifiers using currently available desiccants so as to increase effectiveness without increasing parasitic losses, or developing new desiccants specifically tailored for solar cooling applications. The later part of this paper has considered the second option. A list of desirable desiccant properties was defined, properties of currently used solid and liquid desiccants were compared to this list, and a hypothetical desiccant type that would give improved system performance was discussed.

Collier, R.; Arnold, F.; Barlow, R.

1981-09-01T23:59:59.000Z

472

Desiccant Cooling Systems - A Review  

E-Print Network (OSTI)

Desiccant cooling systems have been investigated extensively during the past decade as alternatives to electrically driven vapor compression systems because regeneration temperatures of the desiccant - about 160F, can be achieved using natural gas or by solar systems. Comfort is achieved by reducing the moisture content of air by a solid or liquid desiccant and then reducing the temperature in an evaporative cooler (direct or indirect). Another system is one where the dehumidifier removes enough moisture to meet the latent portion of the load while the sensible portion is met by a vapor compression cooling system; desiccant regeneration is achieved by using the heat rejected from the condenser together with other thermal sources. At present, residential desiccant cooling systems are in actual operation but are more costly than vapor compression systems, resulting in relatively long payback periods. Component efficiencies need to be improved, particularly the efficiency of the dehumidifier.

Kettleborough, C. F.; Ullah, M. R.; Waugaman, D. G.

1986-01-01T23:59:59.000Z

473

BEFORE THE U.S. DEPARTMENT OF ENERGY  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cloud 9 Marketing, Inc. Cloud 9 Marketing, Inc. d/b/a Winix, Inc. (dehumidifiers) ) ) ) ) ) ) Case Number: 2012-CE-3607 NOTICE OF PROPOSED CIVIL PENALTY Date issued: September 6, 2012 Number of alleged violations: 1460 (4 basic models; 365 days) Maximum possible assessment: $292,000 Proposed civil penalty: $29,200 The U.S. Department of Energy ("DOE") Office of the General CounseJ, Office of Enforcement, alleges that Cloud 9 Marketing, Inc. d/b/a Winix, Inc. ("Winix") has violated ce11ain provisions of the Energy Policy and Conservation Act, 42 U.S.C. § 6291 et seq. ("the Act"), and 10 C.F.R. § 429.12. Specifically, DOE alleges: 1. Winix has manufactured 1 a variety of dehumidifiers, including basic models 2. Winix distributed basic models

474

Undergraduate Handbook 1UNDERGRADUATE HANDBOOK 2013  

E-Print Network (OSTI)

. 1.12. The high-pressure arc lamp studied with x-ray-induced fluorescence consists of a ceramic. The gas under arc- discharge is contained in jackets of ceramic alumina and pyrex, amounting to many. 1.13. X-ray-induced fluorescence spectrum of a 150 W ceramic metal-halide lamp with the lamp off

Waikato, University of

475

Molecular Physics, Vol. 104, Nos. 57, 10 March10 April 2006, 943955 Excited state intramolecular proton transfer  

E-Print Network (OSTI)

in the section "How are LCD Panels Driven?". FIGURE 9: CONTRAST vs. RMS VOLTAGE 100% 90% 10% VOFF VTH VON VRMS of surface on the back of the display requires 2 to 3 watts. FIGURE 10: RESPONSE vs.TEMPERATURE 300 Time LCD panels, such as, incandescent lamps, LEDs, and electrolumi- nescent lamps. Incandescent lamps

Minnesota, University of

476

Hurdling barriers through market uncertainty: Case studies in innovative technology adoption  

E-Print Network (OSTI)

4.5-watt LED lamps replacing the incandescent bulbs. The LEDwatt incandescent bulbs to 4.5 watt LEDs will save 55 kW xLED lamps were compatible with the existing framework of lamp operation they could be used in the same way the incandescent bulbs

Payne, Christopher T.; Radspieler Jr., Anthony; Payne, Jack

2002-01-01T23:59:59.000Z

477

Self-reported Impacts of LED Lighting Technology Compared to Fuel-based Lighting on Night Market Business Prosperity in Kenya  

E-Print Network (OSTI)

s kiosk illuminated by her LED lamp [1/2009] A.N. Market:25 Ksh/night) and Post 07/2008 LED-NiMH lamp (4 Ksh/night) (to charge at a shop) The [LED] lamp is very important and

Johnstone, Peter

2009-01-01T23:59:59.000Z

478

Discussion of Air-Conditioning Energy-Savings in Hot-Summer and Cold-Winter Regions  

E-Print Network (OSTI)

Introducing several kinds of air-conditioning systems energy conservation measures, and according to the climate of the hot-summer and cold-winter region in China, this paper puts forward an overall conception for air-conditioning energy-savings at this area. Namely, we may use the combination of evaporative cooling, dehumidifier and mechanical cooling to save energy for air-conditioning.

Zheng, W.; Gong, F.; Lou, X.; Cheng, J.

2006-01-01T23:59:59.000Z

479

Performance Assessment of an Integrated Cooling/Dehumidification System  

Science Conference Proceedings (OSTI)

This report reviews dehumidification technologies appropriate for residential and commercial building applications with a focus on technologies and system configurations that allow dedicated dehumidification to complement other air conditioning systems, such as direct expansion. One such new technology was tested and is reported on here, the Munters DryCool HD, a small to medium central dehumidifier designed for integration into a ducted air conditioning system. This unit uses both Direct Expansion (DX) ...

2010-11-16T23:59:59.000Z

480

Component- and systems-evaluation study of solar desiccant cooling. Semiannual progress report  

DOE Green Energy (OSTI)

Simulation studies of three system configurations in four different climates have been conducted. These studies have determined some necessary limits for various system parameters. The potential of these systems for providing air conditioning using solar energy only has been examined. The simulation studies are proceeding on schedule. The test facility for experimentally evaluating rotary dehumidifiers performance is under construction at CSIRO. A rotary wheel is being built for use in the tests.

Not Available

1980-07-18T23:59:59.000Z

Note: This page contains sample records for the topic "torchiere lamps dehumidifiers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Hybrid refrigeration/sorption solar-cooling systems  

DOE Green Energy (OSTI)

The hybrid refrigeration/sorption concept is a technically feasible approach to solar cooling which has not yet been systematically evaluated. Various system configurations are possible, each with advantages and disadvantages relative to the others, and with respect to solar cooling systems based on the individual absorption, Rankine, and desiccant technologies. Conventional cooling and dehumidification, sorption dehumidification, and the effects on the refrigeration unit of adding a dehumidifier are discussed.

Curran, H.M.

1981-08-01T23:59:59.000Z

482

Solar air conditioning  

DOE Green Energy (OSTI)

Development of a hybrid solar-assisted air conditioning system that combines a vapor compression section for sensible cooling with a desiccant section for dehumidification and that uses both solar energy and condenser waste heat to drive the dehumidifier has been under way for the last two years (1981 and 1982). The results of this research are included in this report: utilizing solar energy in an economical way has proven quite difficult.

Robison, H.

1981-01-01T23:59:59.000Z

483

Determination of the Transient Dehumidification Characteristics of High Efficiency Central Air Conditioners  

E-Print Network (OSTI)

A series of tests were performed to assesses the dehumidifying performance of residential central air conditioners (CACs). The performance studies were based on factors such as: (i) dynamic performance (ii) the ASHRAE comfort zone, (iii) control strategy and (iv) published performance characteristic of the units. The units were evaluated on their ability to maintain conditions in the ASHRAE comfort zone in a typical residence and typical summer days in Houston, Texas.

Katipamula, S.; O'Neal, D. L.; Somasundaram, S.

1987-01-01T23:59:59.000Z

484

A review of desiccant dehumidification technology  

SciTech Connect

This paper overviews applications of desiccant technology for dehumidifying commercial and institutional buildings. Because of various market, policy, and regulatory factors, this technology is especially attractive for dehumidification applications in the 1990s. After briefly reviewing the principle of operation, the authors present three case studies-for supermarkets, a hotel, and an office building. The authors also discuss recent advances and ongoing research and development activities.

Pesaran, A.A.

1994-10-01T23:59:59.000Z

485

DOE/EA-1662: Environmmental Assessment for Energy Conservation Standards for Cooking Products (April 2009)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Environmental Assessment Environmental Assessment for 10 CFR Part 430 Energy Conservation Program: Energy Conservation Standards for Certain Consumer Products (Dishwashers, Dehumidifiers, Microwave Ovens, and Electric and Gas Kitchen Ranges and Ovens) and for Certain Commercial and Industrial Equipment (Commercial Clothes Washers) April 2009 CHAPTER 16. ENVIRONMENTAL ASSESSMENT TABLE OF CONTENTS 16.1 INTRODUCTION ......................................................................................................... 16-1 16.2 AIR EMISSIONS ANALYSIS...................................................................................... 16-1 16.2.1 Air Emissions Descriptions............................................................................................ 16-1

486

Environmental impacts of lighting technologies - Life cycle assessment and sensitivity analysis  

SciTech Connect

With two regulations, 244/2009 and 245/2009, the European Commission recently put into practice the EuP Directive in the area of lighting devices, aiming to improve energy efficiency in the domestic lighting sector. This article presents a comprehensive life cycle assessment comparison of four different lighting technologies: the tungsten lamp, the halogen lamp, the conventional fluorescent lamp and the compact fluorescent lamp. Taking advantage of the most up-to-date life cycle inventory database available (ecoinvent data version 2.01), all life cycle phases were assessed and the sensitivity of the results for varying assumptions analysed: different qualities of compact fluorescent lamps (production phase), different electricity mixes (use phase), and end-of-life scenarios for WEEE recycling versus municipal solid waste incineration (disposal phase). A functional unit of 'one hour of lighting' was defined and the environmental burdens for the whole life cycle for all four lamp types were calculated, showing a clearly lower impact for the two gas-discharge lamps, i.e. the fluorescent and the compact fluorescent lamp. Differences in the product quality of the compact fluorescent lamps reveal to have only a very small effect on the overall environmental performance of this lamp type; a decline of the actual life time of this lamp type doesn't result in a change of the rank order of the results of the here examined four lamp types. It was also shown that the environmental break-even point of the gas-discharge lamps is reached long before the end of their expected life-span. All in all, it can be concluded that a change from today's tungsten lamp technology to a low-energy-consuming technology such as the compact fluorescent lamp results in a substantial environmental benefit.

Welz, Tobias; Hischier, Roland, E-mail: Roland.Hischier@empa.ch; Hilty, Lorenz M.

2011-04-15T23:59:59.000Z

487

EA-1664: Finding of No Significant Impact | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4: Finding of No Significant Impact 4: Finding of No Significant Impact EA-1664: Finding of No Significant Impact Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps The U.S. Department of Energy has determined that the adoption of energy conservation standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps as described in the final rule titled the "energy Conservation Program: Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector lamps," would not be a major federal action significantly affecting the quality of the human environment. Finding of No Significant Impact for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent

488

History and technical evolution of high frequency fluorescent lighting  

SciTech Connect

This work was performed to accelerate development and commercialization of solid-state, high frequency ballasts for fluorescent lighting systems. The history and development of fluorescent lamps, of ballasts for these fixtures, and of related circuits and equipment are reviewed. The higher lamp efficiency of high-frequency (300 to 3000 Hz) fluorescent lamps as compared with 60 Hz lamps, the development of frequency converter circuits for high-frequency lamps, and uses, electrical characteristics, and economics of these lighting systems are discussed. (LCL)

Campbell, J.H.

1977-12-01T23:59:59.000Z

489

U.S. Department of Energy NEPA Categorical Exclusion Determination Form  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Notice of Proposed Rulemaking for Energy Conservation Standards for Certain Reflector, Elliptical Reflector, Notice of Proposed Rulemaking for Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Reflector Lamps (RIN: 1904-AC15) Program or Field Office:EERE - Buildings Technology Program Location(s} (City/County/State): Nationwide Proposed Action Description: In this NQPR, DOE proposes to adopt new standards for the large diameter Incandescent Reflector Lamps (which will hereafter be referred to as certain "R, ER, and BR IRLs") include: (1) lamps rated 50 watts or less that are ER30, BR30, BR40, or ER40; (2) lamps rated 65 watts that are BR30, BR40, or ER40 lamps; and (3) R20 incandescent reflector lamps rated 45 watts or less. DOE also presents analysis for small diameter lamps and requests further comment on an appropriate standard for these products. The proposed standards, if adopted, would apply to all the

490

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High Intensity Discharge Lamps Test Procedures High Intensity Discharge Lamps Test Procedures Sign up for e-mail updates on regulations for this and other products High-intensity discharge (HID) lamps include mercury vapor (MV), metal halide (MH), and high-pressure sodium (HPS) lamps. The Department of Energy (DOE) is establishing test procedures for HID lamps. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). ( 42 U.S.C. 6291-6309) This Rulemaking is related to the High-Intensity Discharge Lamps Standard and Test Procedure. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of proposed rulemaking regarding test procedures for HID lamps. 76 FR 77914 (Dec. 15, 2011).

491

Lighting Research Group: Facilities: Integrating Sphere  

NLE Websites -- All DOE Office Websites (Extended Search)

Integrating Sphere Integrating Sphere integrating sphere Integrating Sphere Gonio-photometer | Integrating sphere | Power analyzer | Spectro-radiometer The integrating sphere is used to quickly measure the total light output of a lamp. The lamp being tested is placed in the center of the integrating sphere. At one side of the sphere is a light meter which measures the light output of the lamp. Between the lamp and the light meter there is a baffle to prevent the meter from seeing any direct light from the lamp. The inside of the sphere (including the baffle) is coated with a very white paint that reflects all wavelengths equally. This allows us to get very accurate measurements. The light from the lamp bounces around the sphere until it reaches the light meter. It is important that nothing else is in the sphere besides the lamp and the

492

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Metal Halide Lamp Fixtures Metal Halide Lamp Fixtures Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of metal halide lamp fixtures since 2007. A metal halide lamp fixture uses a metal halide lamp and a metal halide lamp ballast. The lamp is the light source and the ballast starts and regulates current. Metal halide fixtures or lighting systems provide lighting for parking lots and streets, flood lighting, athletics facilities, big-box stores, and warehouses. The current standards will save approximately 6.4 quads of energy and result in approximately $9.6 billion in energy bill savings for products shipped from 2009-2038. The standard will avoid about 93.6 million metric tons of carbon dioxide emissions.

493

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Light Emitting Diode Lamps Light Emitting Diode Lamps Sign up for e-mail updates on regulations for this and other products There are currently no energy conservation standards for light emitting diode (LED) lamps.LED lamps are comprised of an LED source, such as LED packages or LED arrays; an LED driver; an American National Standards Institute (ANSI) standard base, and other optical, thermal, mechanical, and electrical components. These LED lamps are primarily used in residential applications as replacement lamps. The Department of Energy (DOE) will conduct an analysis of the energy, emissions, and costs associated with LEDs during any future energy conservation standard rulemakings. The Standards and Test Procedures for this product are related to Rulemaking for Light-Emitting Diode Lamps Test Procedure.

494

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces  

SciTech Connect

This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

Not Available

1993-11-01T23:59:59.000Z

495

Northeastern Rural E M C | Open Energy Information  

Open Energy Info (EERE)

Northeastern Rural E M C Northeastern Rural E M C Jump to: navigation, search Name Northeastern Rural E M C Place Indiana Utility Id 20603 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Outdoor Lighting Energy: Ballasted Lamps 1000W Lighting Outdoor Lighting Energy: Ballasted Lamps 100W Lighting Outdoor Lighting Energy: Ballasted Lamps 150W Lighting Outdoor Lighting Energy: Ballasted Lamps 175W Lighting Outdoor Lighting Energy: Ballasted Lamps 200W Lighting Outdoor Lighting Energy: Ballasted Lamps 250W Lighting

496

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High-Intensity Discharge Lamps Energy Conservation Standard High-Intensity Discharge Lamps Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products High-intensity discharge (HID) lamps include mercury vapor (MV), metal halide (MH), and high-pressure sodium (HPS) lamps. The Department of Energy (DOE) is considering establishing energy conservation standards for certain HID lamps. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). (42 USC 6311-6317) Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of public meeting and availability of interim technical support document regarding energy conservation standards for high-intensity discharge lamps. 78 FR 13566 (February 28, 2013).

497

Lighting Research Group: Facilities: Power Analyzer  

NLE Websites -- All DOE Office Websites (Extended Search)

Power Analyzer Power Analyzer Power Analyzer power analyzer Gonio-photometer | Integrating sphere | Power analyzer | Spectro-radiometer A power analyzer is a very necessary tool for lighting research. With the power analyzer we are able to monitor the input voltage to the lamp as well as the input power and current. The amount of power a lamp or a lamp-ballast combination uses is very important when determining its efficiency. It is also important to monitor the input voltage to make sure it doesn't vary. This can affect the light output of a lamp greatly. With the power analyzer we can also measure things like the power factor, harmonic distortion, and current crest factor of some lamps. These measurements tell us how well a lamp is working. For example, a high power

498

City of Beresford, South Dakota (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Beresford, South Dakota (Utility Company) Beresford, South Dakota (Utility Company) Jump to: navigation, search Name City of Beresford Place South Dakota Utility Id 1601 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Dusk to Dawn Lighting Service- (1000W Lamp) Lighting Dusk to Dawn Lighting Service- (100W Lamp) Lighting Dusk to Dawn Lighting Service- (150W Lamp) Lighting Dusk to Dawn Lighting Service- (250W Lamp) Lighting Dusk to Dawn Lighting Service- (400W Lamp) Lighting Dusk to Dawn Lighting Service- (70W Lamp) Lighting

499

CX-007850: Categorical Exclusion Determination | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

850: Categorical Exclusion Determination 850: Categorical Exclusion Determination CX-007850: Categorical Exclusion Determination Notice of Proposed Rulemaking for Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Reflector Lamps CX(s) Applied: B5.1 Date: 01/09/2012 Location(s): Nationwide Offices(s): Energy Efficiency and Renewable Energy In this Notice of Proposed Rulemaking (NOPR), DOE proposes to adopt new standards for the large diameter Incandescent Reflector Lamps (which will hereafter be referred to as certain "R, ER, and BR IRLs") include: (1) lamps rated 50 watts or less that are ER30, BR30, BR40, or ER40; (2) lamps rated 65 watts that are BR30, BR40, or ER40 lamps; and (3) R20 incandescent reflector lamps rated 45 watts or less. DOE also presents analysis for

500

Quality assurance assessment of new efficient lighting systems for naval ships. Final report. Revision  

SciTech Connect

Ballasts and lamps, which have been selected to replace existing lamp/ballast systems based on improved performance, were tested to determine if they meet standard Naval MIL specifications. Fifty ballasts manufactured by Advance Transformer Corporation and Universal Manufacturing Corporation and 100 lamps manufactured by GTE were tested to determine their quality assurance and durability. These components met all of the MIL specifications that lamp/ballast systems in use must meet. These new systems have an improved system efficacy, 62 lumens per watt, and lower third harmonics, which will reduce the need for generating capacity for lighting on ships. An addendum to the original study describes the assessment of the performance of the advanced ballast system with a new F-17 fluorescent lamp. The results indicate the system performs reliably and shows increased efficacy. This new lamp/ballast system reduces the harmonic content to within Navy limits, and improves the power factor, resulting in a 50% reduction in line current.

Verderber, R.R.; Morse, O.; Dumm, C.

1984-12-01T23:59:59.000Z