National Library of Energy BETA

Sample records for time zone 7

  1. WIPP Concludes Zone Recovery Activities for Panel 7 Disposal...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Activities for Panel 7 Disposal Pathway After months of catch-up rock bolting and contamination mitigation, zone recovery activities along the pathway to Panel 7 have been...

  2. A Time-Domain Electromagnetic Survey of the East Rift Zone Kilauea...

    Open Energy Info (EERE)

    of the East Rift Zone Kilauea Volcano, HawaiiThesisDissertation Author Catherine King Skokan Organization Colorado School of Mines Published Publisher Not Provided, 1974 DOI...

  3. Fault zone structure determined through the analysis of earthquake arrival times

    SciTech Connect (OSTI)

    Michelini, A.

    1991-10-01

    This thesis develops and applies a technique for the simultaneous determination of P and S wave velocity models and hypocenters from a set of arrival times. The velocity models are parameterized in terms of cubic B-splines basis functions which permit the retrieval of smooth models that can be used directly for generation of synthetic seismograms using the ray method. In addition, this type of smoothing limits the rise of instabilities related to the poor resolving power of the data. V{sub P}/V{sub S} ratios calculated from P and S models display generally instabilities related to the different ray-coverages of compressional and shear waves. However, V{sub P}/V{sub S} ratios are important for correct identification of rock types and this study introduces a new methodology based on adding some coupling (i.e., proportionality) between P and S models which stabilizes the V{sub P}/V{sub S} models around some average preset value determined from the data. Tests of the technique with synthetic data show that this additional coupling regularizes effectively the resulting models.

  4. Property:Buildings/ModelClimateZone | Open Energy Information

    Open Energy Info (EERE)

    Climate Zone 7A Climate Zone 7B Climate Zone 8A Climate Zone 8B Pages using the property "BuildingsModelClimateZone" Showing 12 pages using this property. G General Merchandise...

  5. WORKING DRAFT Last Modified 7/13/2014 9:34 PM Pacific Standard Time

    Gasoline and Diesel Fuel Update (EIA)

    DRAFT Last Modified 7/13/2014 9:34 PM Pacific Standard Time Printed 7/13/2014 9:36 PM Pacific Standard Time China Energy Demand Perspective EIA presentation July 2014 CONFIDENTIAL AND PROPRIETARY Any use of this material without specific permission of McKinsey & Company is strictly prohibited Last Modified 7/13/2014 9:34 PM Pacific Standard Time Printed 7/13/2014 9:36 PM Pacific Standard Time McKinsey & Company | 1 Key Points On Asian Energy Demand We have developed a granular view of

  6. Characterization of Vadose Zone Sediment: Borehole C3103 Located in the 216-B-7A Crib Near the B Tank Farm

    SciTech Connect (OSTI)

    Lindenmeier, Clark W.; Serne, R JEFFREY.; Bjornstad, Bruce N.; Last, George V.; Lanigan, David C.; Lindberg, Michael J.; Clayton, Ray E.; Legore, Virginia L.; Kutnyakov, Igor V.; Baum, Steven R.; Geiszler, Keith N.; Valenta, Michelle M.; Vickerman, Tanya S.

    2002-12-01

    This report summarizes data collected from samples in borehole C3103. Borehole C3103 was completed to further characterize the nature and extent of vadose zone contaminants supplied by intentional liquid discharges into the crib 216-B7A/7B between 1954 and 1967. These cribs received dilute waste streams from the bismuth phosphate fuel reprocessing program in the 1950's and decontamination waste in the 1960's. Elevated concentrations of several constituents were primarily measured at different depth intervals. The primary radionuclides present in this borehole are cesium-137 and uranium near the top of the borehole. Chemical characteristics attributed to wastewater-soil interaction at different locations within this zone are elevated pH, sodium, fluoride, carbonate nitrate, and sulphate

  7. Detonation Reaction Zones in Condensed Explosives

    SciTech Connect (OSTI)

    Tarver, C M

    2005-07-14

    Experimental measurements using nanosecond time resolved embedded gauges and laser interferometric techniques, combined with Non-Equilibrium Zeldovich--von Neumann--Doring (NEZND) theory and Ignition and Growth reactive flow hydrodynamic modeling, have revealed the average pressure/particle velocity states attained in reaction zones of self-sustaining detonation waves in several solid and liquid explosives. The time durations of these reaction zone processes is discussed for explosives based on pentaerythritol tetranitrate (PETN), nitromethane, octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), triaminitrinitrobenzene(TATB) and trinitrotoluene (TNT).

  8. ZPR-6 assembly 7 high {sup 240} PU core : a cylindrical assemby with mixed (PU, U)-oxide fuel and a central high {sup 240} PU zone.

    SciTech Connect (OSTI)

    Lell, R. M.; Schaefer, R. W.; McKnight, R. D.; Tsiboulia, A.; Rozhikhin, Y.; Nuclear Engineering Division; Inst. of Physics and Power Engineering

    2007-10-01

    Over a period of 30 years more than a hundred Zero Power Reactor (ZPR) critical assemblies were constructed at Argonne National Laboratory. The ZPR facilities, ZPR-3, ZPR-6, ZPR-9 and ZPPR, were all fast critical assembly facilities. The ZPR critical assemblies were constructed to support fast reactor development, but data from some of these assemblies are also well suited to form the basis for criticality safety benchmarks. Of the three classes of ZPR assemblies, engineering mockups, engineering benchmarks and physics benchmarks, the last group tends to be most useful for criticality safety. Because physics benchmarks were designed to test fast reactor physics data and methods, they were as simple as possible in geometry and composition. The principal fissile species was {sup 235}U or {sup 239}Pu. Fuel enrichments ranged from 9% to 95%. Often there were only one or two main core diluent materials, such as aluminum, graphite, iron, sodium or stainless steel. The cores were reflected (and insulated from room return effects) by one or two layers of materials such as depleted uranium, lead or stainless steel. Despite their more complex nature, a small number of assemblies from the other two classes would make useful criticality safety benchmarks because they have features related to criticality safety issues, such as reflection by soil-like material. The term 'benchmark' in a ZPR program connotes a particularly simple loading aimed at gaining basic reactor physics insight, as opposed to studying a reactor design. In fact, the ZPR-6/7 Benchmark Assembly (Reference 1) had a very simple core unit cell assembled from plates of depleted uranium, sodium, iron oxide, U3O8, and plutonium. The ZPR-6/7 core cell-average composition is typical of the interior region of liquid-metal fast breeder reactors (LMFBRs) of the era. It was one part of the Demonstration Reactor Benchmark Program,a which provided integral experiments characterizing the important features of demonstration-size LMFBRs. As a benchmark, ZPR-6/7 was devoid of many 'real' reactor features, such as simulated control rods and multiple enrichment zones, in its reference form. Those kinds of features were investigated experimentally in variants of the reference ZPR-6/7 or in other critical assemblies in the Demonstration Reactor Benchmark Program.

  9. LOS ALAMOS, New Mexico, March 7, 2012-Former New York Times reporter...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    more than 30 years and also worked at Esquire and Time. He was twice awarded the George Polk Award for National Reporting and for Foreign Affairs Reporting. Now a consulting...

  10. Campaign 1.7 Pu Aging. Development of Time of Flight Secondary Ion Mass Spectroscopy

    SciTech Connect (OSTI)

    Venhaus, Thomas J.

    2015-09-09

    The first application of Time-of-Flight Secondary Ion Mass Spectroscopy (ToF-SIMS) to an aged plutonium surface has resulted in a rich set of surface chemistry data, as well as some unexpected results. FY15 was highlighted by not only the first mapping of hydrogen-containing features within the metal, but also a prove-in series of experiments using the system’s Sieverts Reaction Cell. These experiments involved successfully heating the sample to ~450 oC for nearly 24 hours while the sample was dosed several times with hydrogen, followed by an in situ ToF-SIMS analysis. During this year, the data allowed for better and more consistent identification of the myriad peaks that result from the SIMS sputter process. In collaboration with the AWE (U.K), the system was also fully aligned for sputter depth profiling for future experiments.

  11. Zone separator for multiple zone vessels

    DOE Patents [OSTI]

    Jones, John B. (Grand Junction, CO)

    1983-02-01

    A solids-gas contact vessel, having two vertically disposed distinct reaction zones, includes a dynamic seal passing solids from an upper to a lower zone and maintaining a gas seal against the transfer of the separate treating gases from one zone to the other, and including a stream of sealing fluid at the seal.

  12. Saturated Zone Colloid Transport

    SciTech Connect (OSTI)

    H. S. Viswanathan

    2004-10-07

    This scientific analysis provides retardation factors for colloids transporting in the saturated zone (SZ) and the unsaturated zone (UZ). These retardation factors represent the reversible chemical and physical filtration of colloids in the SZ. The value of the colloid retardation factor, R{sub col} is dependent on several factors, such as colloid size, colloid type, and geochemical conditions (e.g., pH, Eh, and ionic strength). These factors are folded into the distributions of R{sub col} that have been developed from field and experimental data collected under varying geochemical conditions with different colloid types and sizes. Attachment rate constants, k{sub att}, and detachment rate constants, k{sub det}, of colloids to the fracture surface have been measured for the fractured volcanics, and separate R{sub col} uncertainty distributions have been developed for attachment and detachment to clastic material and mineral grains in the alluvium. Radionuclides such as plutonium and americium sorb mostly (90 to 99 percent) irreversibly to colloids (BSC 2004 [DIRS 170025], Section 6.3.3.2). The colloid retardation factors developed in this analysis are needed to simulate the transport of radionuclides that are irreversibly sorbed onto colloids; this transport is discussed in the model report ''Site-Scale Saturated Zone Transport'' (BSC 2004 [DIRS 170036]). Although it is not exclusive to any particular radionuclide release scenario, this scientific analysis especially addresses those scenarios pertaining to evidence from waste-degradation experiments, which indicate that plutonium and americium may be irreversibly attached to colloids for the time scales of interest. A section of this report will also discuss the validity of using microspheres as analogs to colloids in some of the lab and field experiments used to obtain the colloid retardation factors. In addition, a small fraction of colloids travels with the groundwater without any significant retardation. Radionuclides irreversibly sorbed onto this fraction of colloids also transport without retardation. The transport times for these radionuclides will be the same as those for nonsorbing radionuclides. The fraction of nonretarding colloids developed in this analysis report is used in the abstraction of SZ and UZ transport models in support of the total system performance assessment (TSPA) for the license application (LA). This analysis report uses input from two Yucca Mountain Project (YMP) analysis reports. This analysis uses the assumption from ''Waste Form and In-Drift Colloids-Associated Radionuclide Concentrations: Abstraction and Summary'' that plutonium and americium are irreversibly sorbed to colloids generated by the waste degradation processes (BSC 2004 [DIRS 170025]). In addition, interpretations from RELAP analyses from ''Saturated Zone In-Situ Testing'' (BSC 2004 [DIRS 170010]) are used to develop the retardation factor distributions in this analysis.

  13. Climate Zone 7B | Open Energy Information

    Open Energy Info (EERE)

    Colorado Grand County, Colorado Gunnison County, Colorado Hinsdale County, Colorado Jackson County, Colorado Lake County, Colorado Lincoln County, Wyoming Mineral County,...

  14. Climate Zone 7A | Open Energy Information

    Open Energy Info (EERE)

    Minnesota Polk County, Minnesota Price County, Wisconsin Ramsey County, North Dakota Red Lake County, Minnesota Renville County, North Dakota Rolette County, North Dakota...

  15. Climate Zone Number 7 | Open Energy Information

    Open Energy Info (EERE)

    Prince of Wales-Outer Ketchikan Census Area, Alaska Ramsey County, North Dakota Red Lake County, Minnesota Renville County, North Dakota Rio Grande County, Colorado...

  16. ASHRAE Climate Zones | Open Energy Information

    Open Energy Info (EERE)

    navigation, search Subtype A Subtype B Subtype C Climate Zone Number 1 Zone 1A Zone 1B NA Climate Zone Number 2 Zone 2A Zone 2B NA Climate Zone Number 3 Zone 3A Zone 3B Zone...

  17. Renewable Energy Renaissance Zones

    Broader source: Energy.gov [DOE]

    For the purposes of renaissance zone designation, “renewable energy facility” means a facility that creates energy, fuels, or chemicals directly from the wind, the sun, trees, grasses, bio-solids,...

  18. Daylight Savings Time Starts

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Daylight Savings Time Starts Daylight Savings Time Starts WHEN: Mar 08, 2015 3:00 AM - 11:59 PM WHERE: World Time Zones CATEGORY: Holiday INTERNAL: Calendar Login Daylight Savings...

  19. Deep Vadose Zone - Hanford Site

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Long-Range Deep Vadose Zone Program Plan, (Rev. 0) - (PDF) Implementation Plan for the Deep Vadose Zone Applied Field Research Center (DVZ-AFRC) - (PDF) Ecology's groundwater...

  20. Vadose zone water fluxmeter

    DOE Patents [OSTI]

    Faybishenko, Boris A.

    2005-10-25

    A Vadose Zone Water Fluxmeter (WFM) or Direct Measurement WFM provides direct measurement of unsaturated water flow in the vadose zone. The fluxmeter is a cylindrical device that fits in a borehole or can be installed near the surface, or in pits, or in pile structures. The fluxmeter is primarily a combination of tensiometers and a porous element or plate in a water cell that is used for water injection or extraction under field conditions. The same water pressure measured outside and inside of the soil sheltered by the lower cylinder of the fluxmeter indicates that the water flux through the lower cylinder is similar to the water flux in the surrounding soil. The fluxmeter provides direct measurement of the water flow rate in the unsaturated soils and then determines the water flux, i.e. the water flow rate per unit area.

  1. Enterprise Zone | Open Energy Information

    Open Energy Info (EERE)

    Zone Jump to: navigation, search This article is a stub. You can help OpenEI by expanding it. Retrieved from "http:en.openei.orgwindex.php?titleEnterpriseZone&oldid542697"...

  2. Contaminants in Vadose Zone Environments

    Broader source: Energy.gov [DOE]

    The Deep Vadose Zone – Applied Field Research Initiative (DVZ-AFRI) partnered with the Vadose Zone Journal to create a special section of the journal's November 2012 issue.

  3. Renewable liquid reflecting zone plate

    DOE Patents [OSTI]

    Toor, Arthur; Ryutov, Dmitri D.

    2003-12-09

    A renewable liquid reflecting zone plate. Electrodes are operatively connected to a dielectric liquid in a circular or other arrangement to produce a reflecting zone plate. A system for renewing the liquid uses a penetrable substrate.

  4. Radiant zone heated particulate filter

    DOE Patents [OSTI]

    Gonze, Eugene V [Pinckney, MI

    2011-12-27

    A system includes a particulate matter (PM) filter including an upstream end for receiving exhaust gas and a downstream end. A radiant zoned heater includes N zones, where N is an integer greater than one, wherein each of the N zones includes M sub-zones, where M is an integer greater than or equal to one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones, restricts exhaust gas flow in a portion of the PM filter that corresponds to the selected one of the N zones, and deactivates non-selected ones of the N zones.

  5. Santa Clara County- Zoning Ordinance

    Broader source: Energy.gov [DOE]

    Santa Clara County's Zoning Ordinance includes standards for wind and solar structures for residential, agricultural, and commercial uses.

  6. Liquid zone seal

    DOE Patents [OSTI]

    Klebanoff, Leonard E. (Dublin, CA)

    2001-01-01

    A seal assembly that provides a means for establishing multiple pressure zones within a system. The seal assembly combines a plate extending from the inner wall of a housing or inner enclosure that intersects with and is immersed in the fluid contained in a well formed in a tray contained within the enclosure. The fluid is a low vapor pressure oil, chemically inert and oxidation resistant. The use of a fluid as the sealing component provides a seal that is self-healing and mechanically robust not subject to normal mechanical wear, breakage, and formation of cracks or pinholes and decouples external mechanical vibrations from internal structural members.

  7. Breathing zone air sampler

    DOE Patents [OSTI]

    Tobin, John (Bethel Park, PA)

    1989-01-01

    A sampling apparatus is provided which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

  8. City of Austin- Zoning Code

    Broader source: Energy.gov [DOE]

    The Zoning Code also allows for preservation plans in historic districts to incorporate sustainability measures such as solar technologies and other energy generation and efficiency measures.

  9. Western Renewable Energy Zones (Presentation)

    SciTech Connect (OSTI)

    Hein, J.

    2011-06-01

    This presentation summarizes recent developments and trends pertaining to competitive renewable energy zones, transmission planning and the integration of renewable generation resources.

  10. Deep Vadose Zone Field Activities

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    HANFORD ADVISORY BOARD, RAP March 6, 2013 Presented by: John Morse DEEP VADOSE ZONE ACTIVITIES Page 2 Deep Vadose Zone Areas Page 3 Deep Vadose Zone Field Activities FY 2014 Fieldwork Began in 2011 Page 4 Deep Vadose Zone Field Activities, Continued Page 5 0 20,000 40,000 60,000 80,000 100,000 120,000 0 500 1,000 1,500 2,000 2,500 3,000 Cumulative Gallons Removed Weekly Gallons Removed Perched Water Removal Shut down to address increased contamination levels and replace submersible pump Page 6 0

  11. Quasiparticle dynamics across the full Brillouin zone of Bi2Sr2CaCu2O8+ÎŽ traced with ultrafast time and angle-resolved photoemission spectroscopy

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Dakovski, Georgi L.; Durakiewicz, Tomasz; Zhu, Jian-Xin; Riseborough, Peter S.; Gu, Genda; Gilbertson, Steve M.; Taylor, Antoinette; Rodriguez, George

    2015-10-12

    A hallmark in the cuprate family of high-temperature superconductors is the nodal-antinodal dichotomy. In this regard, angle-resolved photoemission spectroscopy (ARPES) has proven especially powerful, providing band structure information directly in energy-momentum space. Time-resolved ARPES (trARPES) holds great promise of adding ultrafast temporal information, in an attempt to identify different interaction channels in the time domain. Previous studies of the cuprates using trARPES were handicapped by the low probing energy which significantly limits the accessible momentum space. Using 20.15eV, 12 fs pulses we show for the first time the evolution of quasiparticles in the antinodal region of Bi2Sr2CaCu2O8+Ύ and demonstrate thatmore »nonmonotonic relaxation dynamics dominates above a certain fluence threshold. The dynamics is heavily influenced by transient modification of the electron-phonon interaction and phase space restrictions, in severe contrast to the monotonic relaxation in the nodal and off-nodal regions.« less

  12. Quasiparticle dynamics across the full Brillouin zone of Bi2Sr2CaCu2O8+ÎŽ traced with ultrafast time and angle-resolved photoemission spectroscopy

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Dakovski, Georgi L.; Durakiewicz, Tomasz; Zhu, Jian-Xin; Riseborough, Peter S.; Gu, Genda; Gilbertson, Steve M.; Taylor, Antoinette; Rodriguez, George

    2015-10-12

    A hallmark in the cuprate family of high-temperature superconductors is the nodal-antinodal dichotomy. In this regard, angle-resolved photoemission spectroscopy (ARPES) has proven especially powerful, providing band structure information directly in energy-momentum space. Time-resolved ARPES (trARPES) holds great promise of adding ultrafast temporal information, in an attempt to identify different interaction channels in the time domain. Previous studies of the cuprates using trARPES were handicapped by the low probing energy which significantly limits the accessible momentum space. Using 20.15eV, 12 fs pulses we show for the first time the evolution of quasiparticles in the antinodal region of Bi2Sr2CaCu2O8+Ύ and demonstrate thatmore » nonmonotonic relaxation dynamics dominates above a certain fluence threshold. The dynamics is heavily influenced by transient modification of the electron-phonon interaction and phase space restrictions, in severe contrast to the monotonic relaxation in the nodal and off-nodal regions.« less

  13. Climate Zones | Department of Energy

    Office of Environmental Management (EM)

    Building America » Climate Zones Climate Zones Building America determines building practices based on climate zones to achieve the most energy savings in a home. This page offers some general guidelines on the definitions of the various climate regions based on heating degree-days, average temperatures, and precipitation. You can also view the Guide to Determining Climate Regions by County. Hot-Humid A hot-humid climate is generally defined as a region that receives more than 20 in. (50 cm) of

  14. Reveal the True Biology: Exploiting Single-Molecule Real-Time DNA Sequencing for Improved Microbial Assembly and Methylome Analysis ( 7th Annual SFAF Meeting, 2012)

    ScienceCinema (OSTI)

    Turner, Steve [Pacific Biosciences

    2013-03-22

    Steve Turner's talk "Reveal the True Biology" at the 2012 Sequencing, Finishing, Analysis in the Future Meeting held June 5-7, 2012 in Santa Fe, New Mexico.

  15. A Low-Velocity Zone in the Basement Beneath the Valles Caldera...

    Open Energy Info (EERE)

    Zone in the Basement Beneath the Valles Caldera, New Mexico Abstract We present quantitative results of forward modeling applied to a suite of travel time delays observed...

  16. Climate Zone 1B | Open Energy Information

    Open Energy Info (EERE)

    Zone Subtype B. Climate Zone 1B is defined as Dry with IP Units 9000 < CDD50F and SI Units 5000 < CDD10C . The following places are categorized as class 1B climate zones:...

  17. Cohesive Zone Model User Element

    Energy Science and Technology Software Center (OSTI)

    2007-04-17

    Cohesive Zone Model User Element (CZM UEL) is an implementation of a Cohesive Zone Model as an element for use in finite element simulations. CZM UEL computes a nodal force vector and stiffness matrix from a vector of nodal displacements. It is designed for structural analysts using finite element software to predict crack initiation, crack propagation, and the effect of a crack on the rest of a structure.

  18. Method for processing seismic data to identify anomalous absorption zones

    DOE Patents [OSTI]

    Taner, M. Turhan

    2006-01-03

    A method is disclosed for identifying zones anomalously absorptive of seismic energy. The method includes jointly time-frequency decomposing seismic traces, low frequency bandpass filtering the decomposed traces to determine a general trend of mean frequency and bandwidth of the seismic traces, and high frequency bandpass filtering the decomposed traces to determine local variations in the mean frequency and bandwidth of the seismic traces. Anomalous zones are determined where there is difference between the general trend and the local variations.

  19. GridZone | Open Energy Information

    Open Energy Info (EERE)

    search Name: GridZone Sector: Efficiency, Services, Transmission Technology: Smart Grid, Energy Storage, Energy Security ParentHolding Organization: GridZone Limited Company...

  20. Transition Zone Geothermal Region | Open Energy Information

    Open Energy Info (EERE)

    Unknown Planned Capacity 1 Geothermal Areas within the Transition Zone Geothermal Region Energy Generation Facilities within the Transition Zone Geothermal Region Geothermal Power...

  1. Wetlands and Riparian Zones | Open Energy Information

    Open Energy Info (EERE)

    Wetlands and Riparian Zones Jump to: navigation, search Retrieved from "http:en.openei.orgwindex.php?titleWetlandsandRiparianZones&oldid612217...

  2. Applied Field Research Initiative Deep Vadose Zone

    Office of Environmental Management (EM)

    in vadose zone environments * Overcomes heterogeneous distribution * Penetrates low-permeability, contaminant source zones Use of Foam Delivery Technology in the subsurface (not to...

  3. December 7

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 December 7 PDSF Users Meeting 12/7/10 Attending: Eric, Katie and Jay from NERSC and users Andrei, Yushu, Thomas, Jeff P., Craig, Joanna Cluster status: Cluster has been full most of the time and is full today. STAR and ALICE running a steady stream of grid jobs. Outages: Yesterday there were GPFS problems related to the kernal issue on some nodes that had not yet been upgraded. This prevented interactive logins for a while. Upcoming downtimes: At some point there will be downtime for home and

  4. Adams County, Washington ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Adams County, Washington ASHRAE Standard ASHRAE 169-2006 Climate Zone Number Climate Zone...

  5. Baroclinic instability in stellar radiation zones

    SciTech Connect (OSTI)

    Kitchatinov, L. L.

    2014-03-20

    Surfaces of constant pressure and constant density do not coincide in differentially rotating stars. Stellar radiation zones with baroclinic stratification can be unstable. Instabilities in radiation zones are of crucial importance for angular momentum transport, mixing of chemical species, and, possibly, for magnetic field generation. This paper performs linear analysis of baroclinic instability in differentially rotating stars. Linear stability equations are formulated for differential rotation of arbitrary shape and then solved numerically for rotation nonuniform in radius. As the differential rotation increases, r- and g-modes of initially stable global oscillations transform smoothly into growing modes of baroclinic instability. The instability can therefore be interpreted as stability loss to r- and g-modes excitation. Regions of stellar parameters where r- or g-modes are preferentially excited are defined. Baroclinic instability onsets at a very small differential rotation of below 1%. The characteristic time of instability growth is about 1000 rotation periods. Growing disturbances possess kinetic helicity. Magnetic field generation by the turbulence resulting from baroclinic instability in differentially rotating radiation zones is therefore possible.

  6. A SUPER-EARTH-SIZED PLANET ORBITING IN OR NEAR THE HABITABLE ZONE AROUND A SUN-LIKE STAR

    SciTech Connect (OSTI)

    Barclay, Thomas; Burke, Christopher J.; Howell, Steve B.; Rowe, Jason F.; Huber, Daniel; Jenkins, Jon M.; Quintana, Elisa V.; Still, Martin; Twicken, Joseph D.; Bryson, Stephen T.; Borucki, William J.; Caldwell, Douglas A.; Clarke, Bruce D.; Christiansen, Jessie L; Coughlin, Jeffrey L.; Ciardi, David; Fischer, Debra A.; and others

    2013-05-10

    We present the discovery of a super-Earth-sized planet in or near the habitable zone of a Sun-like star. The host is Kepler-69, a 13.7 mag G4V-type star. We detect two periodic sets of transit signals in the 3-year flux time series of Kepler-69, obtained with the Kepler spacecraft. Using the very high precision Kepler photometry, and follow-up observations, our confidence that these signals represent planetary transits is >99.3%. The inner planet, Kepler-69b, has a radius of 2.24{sup +0.44}{sub -0.29} R{sub Circled-Plus} and orbits the host star every 13.7 days. The outer planet, Kepler-69c, is a super-Earth-sized object with a radius of 1.7{sup +0.34}{sub -0.23} R{sub Circled-Plus} and an orbital period of 242.5 days. Assuming an Earth-like Bond albedo, Kepler-69c has an equilibrium temperature of 299 {+-} 19 K, which places the planet close to the habitable zone around the host star. This is the smallest planet found by Kepler to be orbiting in or near the habitable zone of a Sun-like star and represents an important step on the path to finding the first true Earth analog.

  7. Vadose Zone Transport Field Study: Summary Report

    SciTech Connect (OSTI)

    Ward, Andy L.; Conrad, Mark E.; Daily, William D.; Fink, James B.; Freedman, Vicky L.; Gee, Glendon W.; Hoversten, Gary M.; Keller, Jason M.; Majer, Ernest L.; Murray, Christopher J.; White, Mark D.; Yabusaki, Steven B.; Zhang, Z. F.

    2006-07-31

    From FY 2000 through FY 2003, a series of vadose zone transport field experiments were conducted as part of the U.S. Department of Energy’s Groundwater/Vadose Zone Integration Project Science and Technology Project, now known as the Remediation and Closure Science Project, and managed by the Pacific Northwest National Laboratory (PNNL). The series of experiments included two major field campaigns, one at a 299-E24-11 injection test site near PUREX and a second at a clastic dike site off Army Loop Road. The goals of these experiments were to improve our understanding of vadose zone transport processes; to develop data sets to validate and calibrate vadose zone flow and transport models; and to identify advanced monitoring techniques useful for evaluating flow-and-transport mechanisms and delineating contaminant plumes in the vadose zone at the Hanford Site. This report summarizes the key findings from the field studies and demonstrates how data collected from these studies are being used to improve conceptual models and develop numerical models of flow and transport in Hanford’s vadose zone. Results of these tests have led to a better understanding of the vadose zone. Fine-scale geologic heterogeneities, including grain fabric and lamination, were observed to have a strong effect on the large-scale behavior of contaminant plumes, primarily through increased lateral spreading resulting from anisotropy. Conceptual models have been updated to include lateral spreading and numerical models of unsaturated flow and transport have revised accordingly. A new robust model based on the concept of a connectivity tensor was developed to describe saturation-dependent anisotropy in strongly heterogeneous soils and has been incorporated into PNNL’s Subsurface Transport Over Multiple Phases (STOMP) simulator. Application to field-scale transport problems have led to a better understanding plume behavior at a number of sites where lateral spreading may have dominated waste migration (e.g. BC Cribs and Trenches). The improved models have been also coupled with inverse models and newly-developed parameter scaling techniques to allow estimation of field-scale and effective transport parameters for the vadose zone. The development and utility of pedotransfer functions for describing fine-scale hydrogeochemical heterogeneity and for incorporating this heterogeneity into reactive transport models was explored. An approach based on grain-size statistics appears feasible and has been used to describe heterogeneity in hydraulic properties and sorption properties, such as the cation exchange capacity and the specific surface area of Hanford sediments. This work has also led to the development of inverse modeling capabilities for time-dependent, subsurface, reactive transport with transient flow fields using an automated optimization algorithm. In addition, a number of geophysical techniques investigated for their potential to provide detailed information on the subtle changes in lithology and bedding surfaces; plume delineation, leak detection. High-resolution resistivity is now being used for detecting saline plumes at several waste sites at Hanford, including tank farms. Results from the field studies and associated analysis have appeared in more than 46 publications generated over the past 4 years. These publications include test plans and status reports, in addition to numerous technical notes and peer reviewed papers.

  8. Deep Vadose Zone | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Deep Vadose Zone Deep Vadose Zone The Mission of the Deep Vadose Zone Applied Field Research Initiative is to protect water resources across the DOE complex over the long-term by developing effective solutions to solve DOE's most challenging deep vadose zone characterization, remediation, monitoring, and prediction challenges. PDF icon Deep Vadose Zone More Documents & Publications Remediation of Mercury and Industrial Contaminants Hanford Site C Tank Farm Meeting Summary - May 2010 Advanced

  9. Zoning and Permitting Resources | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Zoning and Permitting Resources Zoning and Permitting Resources Zoning and permitting is commonly controlled by local governments and may be applicable to both residential and commercial properties. However, the state may regulate the scope of local zoning laws. For instance, some states have passed laws limiting the ability of local governments to prohibit or unreasonably regulate the installation and operation of renewable energy systems. Zoning laws may also be structured to encourage energy

  10. Overlap zoned electrically heated particulate filter

    DOE Patents [OSTI]

    Gonze, Eugene V [Pinckney, MI; Chapman, Mark R [Brighton, MI

    2011-07-19

    A system includes a particulate matter (PM) filter that includes an upstream end for receiving exhaust gas and a downstream end. A zoned heater is arranged spaced from the upstream end and comprises N zones, where N is an integer greater than one, wherein each of the N zones comprises M sub-zones, where M is an integer greater than or equal to one, and wherein the N zones and the M sub-zones are arranged in P layers, where P is an integer greater than one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones and deactivates non-selected ones of the N zones.

  11. Unsaturated Zone and Saturated Zone Transport Properties (U0100)

    SciTech Connect (OSTI)

    J. Conca

    2000-12-20

    This Analysis/Model Report (AMR) summarizes transport properties for the lower unsaturated zone hydrogeologic units and the saturated zone at Yucca Mountain and provides a summary of data from the Busted Butte Unsaturated Zone Transport Test (UZTT). The purpose of this report is to summarize the sorption and transport knowledge relevant to flow and transport in the units below Yucca Mountain and to provide backup documentation for the sorption parameters decided upon for each rock type. Because of the complexity of processes such as sorption, and because of the lack of direct data for many conditions that may be relevant for Yucca Mountain, data from systems outside of Yucca Mountain are also included. The data reported in this AMR will be used in Total System Performance Assessment (TSPA) calculations and as general scientific support for various Process Model Reports (PMRs) requiring knowledge of the transport properties of different materials. This report provides, but is not limited to, sorption coefficients and other relevant thermodynamic and transport properties for the radioisotopes of concern, especially neptunium (Np), plutonium (Pu), Uranium (U), technetium (Tc), iodine (I), and selenium (Se). The unsaturated-zone (UZ) transport properties in the vitric Calico Hills (CHv) are discussed, as are colloidal transport data based on the Busted Butte UZTT, the saturated tuff, and alluvium. These values were determined through expert elicitation, direct measurements, and data analysis. The transport parameters include information on interactions of the fractures and matrix. In addition, core matrix permeability data from the Busted Butte UZTT are summarized by both percent alteration and dispersion.

  12. Sandia defines solar variability zones

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    defines solar variability zones - Sandia Energy Energy Search Icon Sandia Home Locations Contact Us Employee Locator Energy & Climate Secure & Sustainable Energy Future Stationary Power Energy Conversion Efficiency Solar Energy Wind Energy Water Power Supercritical CO2 Geothermal Natural Gas Safety, Security & Resilience of the Energy Infrastructure Energy Storage Nuclear Power & Engineering Grid Modernization Battery Testing Nuclear Fuel Cycle Defense Waste Management Programs

  13. TASK 2: QUENCH ZONE SIMULATION

    SciTech Connect (OSTI)

    Fusselman, Steve

    2015-09-30

    Aerojet Rocketdyne (AR) has developed an innovative gasifier concept incorporating advanced technologies in ultra-dense phase dry feed system, rapid mix injector, and advanced component cooling to significantly improve gasifier performance, life, and cost compared to commercially available state-of-the-art systems. A key feature of the AR gasifier design is the transition from the gasifier outlet into the quench zone, where the raw syngas is cooled to ~ 400°C by injection and vaporization of atomized water. Earlier pilot plant testing revealed a propensity for the original gasifier outlet design to accumulate slag in the outlet, leading to erratic syngas flow from the outlet. Subsequent design modifications successfully resolved this issue in the pilot plant gasifier. In order to gain greater insight into the physical phenomena occurring within this zone, AR developed a cold flow simulation apparatus with Coanda Research & Development with a high degree of similitude to hot fire conditions with the pilot scale gasifier design, and capable of accommodating a scaled-down quench zone for a demonstration-scale gasifier. The objective of this task was to validate similitude of the cold flow simulation model by comparison of pilot-scale outlet design performance, and to assess demonstration scale gasifier design feasibility from testing of a scaled-down outlet design. Test results did exhibit a strong correspondence with the two pilot scale outlet designs, indicating credible similitude for the cold flow simulation device. Testing of the scaled-down outlet revealed important considerations in the design and operation of the demonstration scale gasifier, in particular pertaining to the relative momentum between the downcoming raw syngas and the sprayed quench water and associated impacts on flow patterns within the quench zone. This report describes key findings from the test program, including assessment of pilot plant configuration simulations relative to actual results on the pilot plant gasifier and demonstration plant design recommendations, based on cold flow simulation results.

  14. Farmland Security Zone | Open Energy Information

    Open Energy Info (EERE)

    Security Zone Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- OtherOther: Farmland Security ZoneLegal Abstract California Department of...

  15. Pellet Zone Ltd | Open Energy Information

    Open Energy Info (EERE)

    Pellet Zone Ltd Jump to: navigation, search Name: Pellet Zone Ltd Place: England, United Kingdom Zip: NR19 1AE Sector: Biomass Product: UK based biomass pellet trading firm....

  16. Climate Zone Number 5 | Open Energy Information

    Open Energy Info (EERE)

    Climate Zone Number 5 Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard. Climate Zone Number 5 is defined as Cool- Humid(5A) with IP Units 5400...

  17. Climate Zone 8B | Open Energy Information

    Open Energy Info (EERE)

    Subtype B. Climate Zone 8B is defined as Subarctic with IP Units 12600 < HDD65F and SI Units 7000 < HDD18C . The following places are categorized as class 8B climate zones:...

  18. Climate Zone 8A | Open Energy Information

    Open Energy Info (EERE)

    A. Climate Zone Number 8A is defined as Subarctic with IP Units 12600 < HDD65F and SI Units 7000 < HDD18C . The following places are categorized as class 8A climate zones:...

  19. Climate Zone 1A | Open Energy Information

    Open Energy Info (EERE)

    A. Climate Zone 1A is defined as Very Hot - Humid with IP Units 9000 < CDD50F and SI Units 5000 < CDD10C . The following places are categorized as class 1A climate zones:...

  20. Zero Zone Comment | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Zero Zone Comment Zero Zone Comment These comments are submitted by Zero Zone Inc., a manufacturer of CRE equipment, in response to the U.S. Department of Energy's (DOE) notice in the July 3, 2014 Federal Register requesting information to assist DOE in reviewing existing regulations and in making its regulatory program more effective and less burdensome. PDF icon Zero Zone comments More Documents & Publications Regulatory Burden RFI Executive Order 13563 certification, compliance and

  1. MAGNETIZED ACCRETION AND DEAD ZONES IN PROTOSTELLAR DISKS

    SciTech Connect (OSTI)

    Dzyurkevich, Natalia; Henning, Thomas; Turner, Neal J.; Kley, Wilhelm

    2013-03-10

    The edges of magnetically dead zones in protostellar disks have been proposed as locations where density bumps may arise, trapping planetesimals and helping form planets. Magneto-rotational turbulence in magnetically active zones provides both accretion of gas on the star and transport of mass to the dead zone. We investigate the location of the magnetically active regions in a protostellar disk around a solar-type star, varying the disk temperature, surface density profile, and dust-to-gas ratio. We also consider stellar masses between 0.4 and 2 M{sub Sun }, with corresponding adjustments in the disk mass and temperature. The dead zone's size and shape are found using the Elsasser number criterion with conductivities including the contributions from ions, electrons, and charged fractal dust aggregates. The charged species' abundances are found using the approach proposed by Okuzumi. The dead zone is in most cases defined by the ambipolar diffusion. In our maps, the dead zone takes a variety of shapes, including a fish tail pointing away from the star and islands located on and off the midplane. The corresponding accretion rates vary with radius, indicating locations where the surface density will increase over time, and others where it will decrease. We show that density bumps do not readily grow near the dead zone's outer edge, independently of the disk parameters and the dust properties. Instead, the accretion rate peaks at the radius where the gas-phase metals freeze out. This could lead to clearing a valley in the surface density, and to a trap for pebbles located just outside the metal freezeout line.

  2. Atkinson County, Georgia ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Atkinson County, Georgia ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Atkinson County, Georgia ASHRAE Standard ASHRAE 169-2006 Climate Zone...

  3. Barron County, Wisconsin ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Barron County, Wisconsin ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Barron County, Wisconsin ASHRAE Standard ASHRAE 169-2006 Climate Zone...

  4. Becker County, Minnesota ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Becker County, Minnesota ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Becker County, Minnesota ASHRAE Standard ASHRAE 169-2006 Climate Zone...

  5. Alfalfa County, Oklahoma ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Alfalfa County, Oklahoma ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Alfalfa County, Oklahoma ASHRAE Standard ASHRAE 169-2006 Climate Zone...

  6. Adams County, Mississippi ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Adams County, Mississippi ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Adams County, Mississippi ASHRAE Standard ASHRAE 169-2006 Climate Zone...

  7. Central Nevada Seismic Zone Geothermal Region | Open Energy Informatio...

    Open Energy Info (EERE)

    Central Nevada Seismic Zone Geothermal Region (Redirected from Central Nevada Seismic Zone) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Central Nevada Seismic Zone...

  8. Anderson County, Kentucky ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Anderson County, Kentucky ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Anderson County, Kentucky ASHRAE Standard ASHRAE 169-2006 Climate Zone...

  9. Dead Zones in LX-17 and PBX 9502

    SciTech Connect (OSTI)

    Souers, P C; Andreski, H G; Batteux, J; Bratton, B; Cabacungan, C; Cook, III, C F; Fletcher, S; Garza, R; Grimsley, D; Handly, J; Hernandez, A; McMaster, P; Molitoris, J D; Palmer, R; Prindiville, J; Rodriguez, J; Schneberk, D; Wong, B; Vitello, P

    2005-09-06

    Pin and X-ray corner-turning data have been taken on ambient LX-17 and PBX 9052, and the results are listed in tables as an aid to future modeling. The results have been modeled at 4 zones/mm with a reactive flow approach that varies the burn rate as a function of pressure. A single rate format is used to simulate failure and detonation in different pressure regimes. A pressure cut-off must also be reached to initiate the burn. Corner-turning and failure are modeled using an intermediate pressure rate region, and detonation occurs at high pressure. The TATB booster is also modeled using reactive flow, and X-ray tomography is used to partition the ram-pressed hemisphere into five different density regions. The model reasonably fits the bare corner-turning experiment but predicts a smaller dead zone with steel confinement, in contradiction with experiment. The same model also calculates the confined and unconfined cylinder detonation velocities and predicts the failure of the unconfined cylinder at 3.75 mm radius. The PBX 9502 shows a smaller dead zone than LX-17. An old experiment that showed a large apparent dead zone in Comp B was repeated with X-ray transmission and no dead zone was seen. This confirms the idea that a variable burn rate is the key to modeling. The model also produces initiation delays, which are shorter than those found in time-to-detonation.

  10. U.S. Climate Zones Map for Commercial Buildings

    U.S. Energy Information Administration (EIA) Indexed Site

    Past Climate Zones U. S. Climate Zones for 1979-1999 CBECS: climate zone map Return to Climate Zones for 2003 CBECS Return to CBECS Home Page Note:Map updated with corrections,...

  11. Property:ASHRAE 169 Climate Zone Subtype | Open Energy Information

    Open Energy Info (EERE)

    A + Adair County, Oklahoma ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A + Adams County, Colorado ASHRAE 169-2006 Climate Zone + Climate Zone Subtype B + Adams County,...

  12. Property:ASHRAE 169 Climate Zone Number | Open Energy Information

    Open Energy Info (EERE)

    5 + Adair County, Oklahoma ASHRAE 169-2006 Climate Zone + Climate Zone Number 3 + Adams County, Colorado ASHRAE 169-2006 Climate Zone + Climate Zone Number 5 + Adams County,...

  13. U.S. Climate Zones Map for Commercial Buildings

    U.S. Energy Information Administration (EIA) Indexed Site

    U.S. Climate Zone U. S. Climate Zones for 2003 CBECS: climate zones map Note:Map updated with corrections, February 2012 Further Explanation on How Climate Zones are Defined...

  14. Coastal Zone Management Act | Open Energy Information

    Open Energy Info (EERE)

    and the National Estuarine Research Reserve System. The 34 coastal programs aim to balance competing land and water issues in the coastal zone, while estuarine reserves serve...

  15. Mapping Hydrothermal Upwelling and Outflow Zones: Preliminary...

    Open Energy Info (EERE)

    temperature anomaly has been mapped. A group of subtle temperature anomalies along Simpson Pass, south of the current production area, are interpreted as an upwelling zone with...

  16. Coastal Zone Management Act and Regulations (NOAA)

    Broader source: Energy.gov [DOE]

    The Coastal Zone Management Act (CZMA) of 1972 provides for the management of the nation’s coastal resources, including the Great Lakes.

  17. Vadose Zone Microbiology: Science and Applications

    SciTech Connect (OSTI)

    Brockman, Fred J.; Bradley, Stephen D.; Kieft, Thomas L.

    2002-03-12

    Brockman FJ, SN Bradley and TL Kieft. 2002. Vadose zone microbiology. In Encyclopedia of Environmental Microbiology, volume 6, pp. 3236-3246. John Wiley and Sons, New York.

  18. Maricopa County- Renewable Energy Systems Zoning Ordinance

    Broader source: Energy.gov [DOE]

    The Maricopa County Zoning Ordinance contains provisions for siting renewable energy systems. The ordinance defines renewable energy as "energy derived primarily from sources other than fossil...

  19. Coastal Zone Management Act and Regulations

    Broader source: Energy.gov [DOE]

    The Coastal Zone Management Act (CZMA) of 1972 provides for the management of the nation’s coastal resources, including the Great Lakes.

  20. Climate Zone 2B | Open Energy Information

    Open Energy Info (EERE)

    are categorized as class 2B climate zones: Bandera County, Texas Dimmit County, Texas Edwards County, Texas Frio County, Texas Imperial County, California Kinney County, Texas La...

  1. Washington Coastal Zone Management Regulatory Handbook | Open...

    Open Energy Info (EERE)

    to library PermittingRegulatory Guidance - GuideHandbook: Washington Coastal Zone Management Regulatory HandbookPermittingRegulatory GuidanceGuideHandbook Author Washington...

  2. Near-field/altered-zone models report

    SciTech Connect (OSTI)

    Hardin, E. L., LLNL

    1998-03-01

    The U.S. Department of Energy is studying Yucca Mountain as the possible site for the first underground repository for permanent disposal of spent fuel from commercial nuclear reactors as well as for other types high-level nuclear waste. Emplacement of high-level radioactive waste, especially commercial spent nuclear fuel (CSNF), in Yucca Mountain will release a large amount of heat into the rock above and below the repository. The heating rate will decrease with time, creating a thermal pulse. Over a period of several thousand years, the rock temperature will rise initially, then drop when the production of decay heat falls below the rate at which heat escapes from the hot zone. Besides raising the rock temperature, much of this heat will vaporize water, which will then condense in cooler regions. The condensate is likely to form a gravity-driven heat pipe above the repository, creating the possibility that water may drain back onto the waste packages (WPs) or that it may ''shed'' through the pillars between emplacement drifts. The long-term importance of these effects has been investigated through the development, testing, and application of thermohydrologic (TH) models. Other effects, such coupled chemical and mechanical processes, may also influence the movement of water above, within, and below the emplacement drifts. A recent report on thermally driven coupled processes (Hardin and Chesnut, 1997) provides a qualitative assessment of the probable significance of these processes for the Yucca Mountain Site Characterization Project (YMSCP) and is the phenomenological framework for the present report. This report describes the conceptual and numerical models that have been developed to predict the thermal, mechanical, hydrologic, and chemical responses to the cumulative heat production of the potential host rock at Yucca Mountain. As proposed, the repository horizon will be situated within the Topopah Spring tuff, in the adjacent middle nonlithophysal and lower lithophysal units. These units are made up of moderately to densely welded, devitrified, fractured tuff. The rock's chemical composition is comparable to that of typical granite, but has textural features and mineralogical characteristics of large-scale, silicic volcanism. Because the repository horizon will be approximately 300 m below the ground surface and 200 m above the water table, the repository will be partially saturated. The welded tuff matrix in the host units is highly impermeable, but water and gas flow readily through fractures. The degree of fracturing in these units is highly variable, and the hydrologic significance of fracturing is an important aspect of site investigation. This report describes the characterization and modeling of a region around the potential repository--the altered zone--a region in which the temperature will be increased significantly by waste-generated heat. Numerical simulation has shown that, depending on the boundary conditions, rock properties, and repository design features incorporated in the models, the altered zone (AZ) may extend from the water table to the ground surface. This report also describes models of the near field, the region comprising the repository emplacement drifts and the surrounding rock, which are critical to the performance of engineered components. Investigations of near-field and altered-zone (NF/AZ) processes support the design of underground repository facilities and engineered barriers and also provide constraint data for probabilistic calculations of waste-isolation performance (i.e., performance assessment). The approach to investigation, which is an iterative process involving hypothesis testing and experimentation, has relied on conceptualizing engineered barriers and on performance analysis. This report is a collection, emphasizing conceptual and numerical models, of the recent results contributed from studies of NF/AZ processes and of quantitative measures of NF/AZ performance. The selection and presentation of contributions are intended to show the iterative development of understand

  3. How Do You Reduce the Time You Spend Idling? | Department of Energy

    Energy Savers [EERE]

    Reduce the Time You Spend Idling? How Do You Reduce the Time You Spend Idling? November 4, 2010 - 7:30am Addthis On Tuesday, Shannon discussed some efforts by Clean Cities, parents, and students to reduce the time that parents spend idling in school parking lots. Some schools have even become idle-free zones. The Alternative Fuels and Advanced Vehicles Data Center offers a few tips for reducing idling, including turning off your engine if you are parked for more than a minute, switching to a

  4. Treating tar sands formations with karsted zones

    DOE Patents [OSTI]

    Vinegar, Harold J. (Bellaire, TX); Karanikas, John Michael (Houston, TX)

    2010-03-09

    Methods for treating a tar sands formation are described herein. The tar sands formation may have one or more karsted zones. Methods may include providing heat from one or more heaters to one or more karsted zones of the tar sands formation to mobilize fluids in the formation. At least some of the mobilized fluids may be produced from the formation.

  5. Table HC9.6 Air Conditioning Characteristics by Climate Zone, 2005

    Gasoline and Diesel Fuel Update (EIA)

    6 Air Conditioning Characteristics by Climate Zone, 2005 Million U.S. Housing Units Total......................................................................... 111.1 10.9 26.1 27.3 24.0 22.8 Do Not Have Cooling Equipment........................... 17.8 3.2 4.7 3.6 5.5 0.9 Have Cooling Equipment........................................ 93.3 7.7 21.4 23.7 18.5 21.9 Use Cooling Equipment......................................... 91.4 7.6 21.0 23.4 17.9 21.7 Have Equipment But Do Not Use

  6. 7Be

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7Be(EC); measured decay products, E, I; deduced precise T12 values for different materials. Measurements for Branching Ratios 1938RU01: 7Be. 1948KU10: 7Be; measured E....

  7. Confined zone dispersion flue gas desulfurization demonstration

    SciTech Connect (OSTI)

    Not Available

    1992-02-27

    The confined zone dispersion (CZD) process involves flue gas post-treatment, physically located between a boiler's outlet and its particulate collector, which in the majority of cases is an electrostatic precipitator. The features that distinguish this process from other similar injection processes are: Injection of an alkaline slurry directly into the duct, instead of injection of dry solids into the duct ahead of a fabric filter. Use of an ultrafine calcium/magnesium hydroxide, type S pressure-hydrated dolomitic lime. This commercial product is made from plentiful, naturally occurring dolomite. Low residence time, made possible by the high effective surface area of the Type S lime. Localized dispersion of the reagent. Slurry droplets contact only part of the gas while the droplets are drying, to remove up to 50 percent of the S0{sub 2} and significant amounts of NO{sub x}. The process uses dual fluid rather than rotary atomizers. Improved electrostatic precipitator performance via gas conditioning from the increased water vapor content, and lower temperatures. Supplemental conditioning with S0{sub 3} is not believed necessary for satisfactory removal of particulate matter.

  8. 7He

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    He Ground-State Decay Evaluated Data Measured Ground-State Γcm for 7He Adopted value: 150 ± 20 keV (2002TI10) Measured Mass Excess for 7He Adopted value: 26101 ± 17 keV (2003AU02) Measurements 1960BA51: 7He; measured not abstracted; deduced nuclear properties. 1965DE08: 7He; measured not abstracted; deduced nuclear properties. 1967ST04: 7He; measured not abstracted; deduced nuclear properties. 1969ST02: 7Li(t, 3He), E = 22 MeV; measured Q, σ(E(3He), Ξ). 7He deduced ground-state level-width.

  9. Mobile machine hazardous working zone warning system

    DOE Patents [OSTI]

    Schiffbauer, William H. (Connellsville, PA); Ganoe, Carl W. (Pittsburgh, PA)

    1999-01-01

    A warning system is provided for a mobile working machine to alert an individual of a potentially dangerous condition in the event the individual strays into a hazardous working zone of the machine. The warning system includes a transmitter mounted on the machine and operable to generate a uniform magnetic field projecting beyond an outer periphery of the machine in defining a hazardous working zone around the machine during operation thereof. A receiver, carried by the individual and activated by the magnetic field, provides an alarm signal to alert the individual when he enters the hazardous working zone of the machine.

  10. DOE - NNSA/NFO -- Kids Zone

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ZONE NNSA/NFO Language Options U.S. DOE/NNSA - Nevada Field Office Cartoon drawing of science girl Kids Zone Welcome K-12 students and teachers! The NNSA/NFO Kids Zone contains information regarding the Nevada Regional Science Bowl, the Environmental Management Kids Display/Activity Book, Student Forum, and lots of photos. Teachers - You can also request a speaker for your classroom or school by filling out the Speakers Bureau Request Form. Feel free to browse the site and come back often as we

  11. Mobile machine hazardous working zone warning system

    DOE Patents [OSTI]

    Schiffbauer, W.H.; Ganoe, C.W.

    1999-08-17

    A warning system is provided for a mobile working machine to alert an individual of a potentially dangerous condition in the event the individual strays into a hazardous working zone of the machine. The warning system includes a transmitter mounted on the machine and operable to generate a uniform magnetic field projecting beyond an outer periphery of the machine in defining a hazardous working zone around the machine during operation. A receiver, carried by the individual and activated by the magnetic field, provides an alarm signal to alert the individual when he enters the hazardous working zone of the machine. 3 figs.

  12. Coiled tubing isolates zones, fractures wells with single trip service

    SciTech Connect (OSTI)

    Silverman, S.A.

    1999-04-01

    A system has been devised that combines high pressure coiled tubing (CT) and a selective isolation technique to frac multiple zones in a single operation. Multiple zones in one well can be individually isolated, fractured and flowed back simultaneously which results in reduced exposure to kill fluids and therefore higher retained conductivity for newly created fractures. The technique has been named CoilFRAC{trademark} by Dowell. The key benefits to the entire operation are reduced rig and operations time compared to conventional fracturing processes. Time savings, increased production, and environmental benefits are the economic drivers that result in rapid return on investment for production operators. The single trip concept for perforating and stimulation crews also brings additional benefits over multiple mobilizations. Wells which previously had only major zones perforated and stimulated and which are currently depleted can be revived economically using this system, giving the well a second life. The paper describes the equipment and its safety and contingency features, optimized shallow gas production in Alberta, and results from a South Texas oil well fracturing.

  13. Metagenome of a Versatile Chemolithoautotroph from Expanding Oceanic Dead Zones

    SciTech Connect (OSTI)

    Walsh, David A.; Zaikova, Elena; Howes, Charles L.; Song, Young; Wright, Jody; Tringe, Susannah G.; Tortell, Philippe D.; Hallam, Steven J.

    2009-07-15

    Oxygen minimum zones (OMZs), also known as oceanic"dead zones", are widespread oceanographic features currently expanding due to global warming and coastal eutrophication. Although inhospitable to metazoan life, OMZs support a thriving but cryptic microbiota whose combined metabolic activity is intimately connected to nutrient and trace gas cycling within the global ocean. Here we report time-resolved metagenomic analyses of a ubiquitous and abundant but uncultivated OMZ microbe (SUP05) closely related to chemoautotrophic gill symbionts of deep-sea clams and mussels. The SUP05 metagenome harbors a versatile repertoire of genes mediating autotrophic carbon assimilation, sulfur-oxidation and nitrate respiration responsive to a wide range of water column redox states. Thus, SUP05 plays integral roles in shaping nutrient and energy flow within oxygen-deficient oceanic waters via carbon sequestration, sulfide detoxification and biological nitrogen loss with important implications for marine productivity and atmospheric greenhouse control.

  14. Systematic investigation of effects of exciton–acoustic-phonon scattering on photoluminescence rise times of free excitons in GaAs/Al{sub 0.3}Ga{sub 0.7}As single quantum wells

    SciTech Connect (OSTI)

    Nakayama, Masaaki Ohno, Tatsuya; Furukawa, Yoshiaki

    2015-04-07

    We have systematically investigated the photoluminescence (PL) dynamics of free excitons in GaAs/Al{sub 0.3}Ga{sub 0.7}As single quantum wells, focusing on the energy relaxation process due to exciton–acoustic-phonon scattering under non-resonant and weak excitation conditions as a function of GaAs-layer thickness from 3.6 to 12.0 nm and temperature from 30 to 50 K. The free exciton characteristics were confirmed by observation that the PL decay time has a linear dependence with temperature. We found that the free exciton PL rise rate, which is the reciprocal of the rise time, is inversely linear with the GaAs-layer thickness and linear with temperature. This is consistent with a reported theoretical study of the exciton–acoustic-phonon scattering rate in the energy relaxation process in quantum wells. Consequently, it is conclusively verified that the PL rise rate is dominated by the exciton–acoustic-phonon scattering rate. In addition, from quantitative analysis of the GaAs-layer thickness and temperature dependences, we suggest that the PL rise rate reflects the number of exciton–acoustic-phonon scattering events.

  15. Category:ASHRAE Climate Zones | Open Energy Information

    Open Energy Info (EERE)

    Category Edit History Category:ASHRAE Climate Zones Jump to: navigation, search Climate Zones defined in the ASHRAE 169-2006 standards. Pages in category "ASHRAE Climate Zones" The...

  16. China-Low Carbon Development Zones | Open Energy Information

    Open Energy Info (EERE)

    China-Low Carbon Development Zones (Redirected from E3G-China-Low Carbon Development Zones) Jump to: navigation, search Name China-Low Carbon Development Zones AgencyCompany...

  17. Local Option- Rural Renewable Energy Development Zones

    Broader source: Energy.gov [DOE]

    Commercial renewable energy property in these zones are eligible for a 3 to 5 year local property tax exemption. Eligible property includes either wind, geothermal, solar, biomass, or other uncon...

  18. Climate Zone 5C | Open Energy Information

    Open Energy Info (EERE)

    C. Climate Zone 5C is defined as Marine with IP Units 5400 < HDD65F 7200 and SI Units 3000 < HDD18C 4000 . The following places are categorized as class 5C...

  19. Vadose Zone Transport Field Study: Status Report

    SciTech Connect (OSTI)

    Gee, Glendon W.; Ward, Anderson L.

    2001-11-30

    Studies were initiated at the Hanford Site to evaluate the process controlling the transport of fluids in the vadose zone and to develop a reliable database upon which vadose-zone transport models can be calibrated. These models are needed to evaluate contaminant migration through the vadose zone to underlying groundwaters at Hanford. A study site that had previously been extensively characterized using geophysical monitoring techniques was selected in the 200 E Area. Techniques used previously included neutron probe for water content, spectral gamma logging for radionuclide tracers, and gamma scattering for wet bulk density. Building on the characterization efforts of the past 20 years, the site was instrumented to facilitate the comparison of nine vadose-zone characterization methods: advanced tensiometers, neutron probe, electrical resistance tomography (ERT), high-resolution resistivity (HRR), electromagnetic induction imaging (EMI), cross-borehole radar (XBR), and cross-borehole seismic (XBS). Soil coring was used to obtain soil samples for analyzing ionic and isotopic tracers.

  20. A=7 Nuclides

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 Publications: revised manuscripts of: Evaluations PDF HTML TUNL evaluation (2002) A = 7 7H, 7He, 7Li, 7Be, 7B FAS evaluation (1988) A = 7 7H, 7He, 7Li, 7Be, 7B FAS evaluation (1984) A = 7 7H, 7He, 7Li, 7Be, 7B, 7C FAS evaluation (1979) A = 7 7n, 7H, 7He, 7Li, 7Be, 7B FAS evaluation (1974) A = 7 7H, 7He, 7Li, 7Be, 7B FAS evaluation (1966) A = 7 7He, 7Li, 7Be, 7B FAS evaluation (1959) A = 7 7He, 7Li, 7Be Tables of Adopted Levels: 7He, 7Li, 7Be Energy Level Diagrams: 7He, 7Li, 7Be, isobar diagram

  1. Treating nahcolite containing formations and saline zones

    DOE Patents [OSTI]

    Vinegar, Harold J

    2013-06-11

    A method for treating a nahcolite containing subsurface formation includes removing water from a saline zone in or near the formation. The removed water is heated using a steam and electricity cogeneration facility. The heated water is provided to the nahcolite containing formation. A fluid is produced from the nahcolite containing formation. The fluid includes at least some dissolved nahcolite. At least some of the fluid is provided to the saline zone.

  2. Zone heated diesel particulate filter electrical connection

    DOE Patents [OSTI]

    Gonze, Eugene V. (Pinckney, MI); Paratore, Jr., Michael J. (Howell, MI)

    2010-03-30

    An electrical connection system for a particulate filter is provided. The system includes: a particulate filter (PF) disposed within an outer shell wherein the PF is segmented into a plurality of heating zones; an outer mat disposed between the particulate filter and the outer shell; an electrical connector coupled to the outer shell of the PF; and a plurality of printed circuit connections that extend along the outer surface of the PF from the electrical connector to the plurality of heating zones.

  3. 7B

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    B Ground-State Decay Evaluated Data Measured Ground-State Γcm for 7B Adopted value: 801 ± 20 keV (2011CH32) Measured Mass Excess for 7B Adopted value: 27677 ± 25 keV (2012WA38) Measurements 1965DE08: 7B; measured not abstracted; deduced nuclear properties. 1967MC14: 7B; measured not abstracted; deduced nuclear properties. 2000DR19: 7Li(π+, π-), E = 30 - 90 MeV; measured σ(E, Ξ); deduced energy and mass dependence features. 2002LE16: 7Li(14N, 14B), E = 30 MeV/nucleon; measured particle

  4. Montana Streamside Management Zone Law Webpage | Open Energy...

    Open Energy Info (EERE)

    Zone Law Webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Montana Streamside Management Zone Law Webpage Abstract Provides information on...

  5. Alameda County, California ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Alameda County, California ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Alameda County, California ASHRAE Standard ASHRAE 169-2006 Climate...

  6. Longyang Zone Hongqiang Hydroelectric Power Development Co Ltd...

    Open Energy Info (EERE)

    Longyang Zone Hongqiang Hydroelectric Power Development Co Ltd Jump to: navigation, search Name: Longyang Zone Hongqiang Hydroelectric Power Development Co., Ltd. Place: Baoshan...

  7. Future Energy Zone Private Ltd FEZ | Open Energy Information

    Open Energy Info (EERE)

    Zone Private Ltd FEZ Jump to: navigation, search Name: Future Energy Zone Private Ltd (FEZ) Place: Chennai, Tamil Nadu, India Sector: Renewable Energy Product: Focused on building...

  8. Belknap County, New Hampshire ASHRAE 169-2006 Climate Zone |...

    Open Energy Info (EERE)

    Help Apps Datasets Community Login | Sign Up Search Page Edit History Belknap County, New Hampshire ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone...

  9. Androscoggin County, Maine ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Apps Datasets Community Login | Sign Up Search Page Edit History Androscoggin County, Maine ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place...

  10. DOE New Madrid Seismic Zone Electric Utility Workshop Summary...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    New Madrid Seismic Zone Electric Utility Workshop Summary Report - August 2010 DOE New Madrid Seismic Zone Electric Utility Workshop Summary Report - August 2010 The DOE New Madrid...

  11. Adams County, Pennsylvania ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Adams County, Pennsylvania ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Adams County, Pennsylvania ASHRAE Standard ASHRAE 169-2006 Climate...

  12. Bernalillo County, New Mexico ASHRAE 169-2006 Climate Zone |...

    Open Energy Info (EERE)

    Bernalillo County, New Mexico ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Bernalillo County, New Mexico ASHRAE Standard ASHRAE 169-2006...

  13. An Updated Site Scale Saturated Zone Ground Water Transport Model...

    Office of Scientific and Technical Information (OSTI)

    An Updated Site Scale Saturated Zone Ground Water Transport Model for Yucca Mountain. Citation Details In-Document Search Title: An Updated Site Scale Saturated Zone Ground Water ...

  14. Walker-Lane Transition Zone Geothermal Region | Open Energy Informatio...

    Open Energy Info (EERE)

    At Walker-Lane Transitional Zone Region (Coolbaugh, Et Al., 2005 - 2) Direct-Current Resistivity Survey At Walker-Lane Transitional Zone Region (Pritchett,...

  15. Berkeley County, South Carolina ASHRAE 169-2006 Climate Zone...

    Open Energy Info (EERE)

    Berkeley County, South Carolina ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Berkeley County, South Carolina ASHRAE Standard ASHRAE 169-2006...

  16. Berkeley County, West Virginia ASHRAE 169-2006 Climate Zone ...

    Open Energy Info (EERE)

    Berkeley County, West Virginia ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Berkeley County, West Virginia ASHRAE Standard ASHRAE 169-2006...

  17. Haleakala SW Rift Zone Exploration | Open Energy Information

    Open Energy Info (EERE)

    SW Rift Zone Exploration Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Development Project: Haleakala SW Rift Zone Exploration Project Location Information...

  18. Geodetic Survey At Walker-Lane Transitional Zone Region (Blewitt...

    Open Energy Info (EERE)

    Zone Region (Blewitt Et Al, 2005) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Geodetic Survey Activity Date...

  19. Field Mapping At Walker-Lane Transitional Zone Region (Blewitt...

    Open Energy Info (EERE)

    Zone Region (Blewitt Et Al, 2005) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Field Mapping Activity Date Usefulness...

  20. Teleseismic-Seismic Monitoring At Walker-Lane Transitional Zone...

    Open Energy Info (EERE)

    Zone Region (Biasi, Et Al., 2009) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Teleseismic-Seismic Monitoring Activity...

  1. Compound and Elemental Analysis At Walker-Lane Transitional Zone...

    Open Energy Info (EERE)

    Zone Region (Laney, 2005) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Compound and Elemental Analysis...

  2. Isotopic Analysis At Walker-Lane Transitional Zone Region (Laney...

    Open Energy Info (EERE)

    Zone Region (Laney, 2005) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Isotopic Analysis- Fluid Activity Date...

  3. Teleseismic-Seismic Monitoring At Walker-Lane Transitional Zone...

    Open Energy Info (EERE)

    Zone Region (Biasi, Et Al., 2008) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Teleseismic-Seismic Monitoring Activity...

  4. Geographic Information System At Walker-Lane Transitional Zone...

    Open Energy Info (EERE)

    Zone Region (Laney, 2005) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Geographic Information System Activity...

  5. Geothermometry At Walker-Lane Transitional Zone Region (Laney...

    Open Energy Info (EERE)

    Zone Region (Laney, 2005) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Geothermometry Activity Date Usefulness...

  6. Alleghany County, North Carolina ASHRAE 169-2006 Climate Zone...

    Open Energy Info (EERE)

    Alleghany County, North Carolina ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Alleghany County, North Carolina ASHRAE Standard ASHRAE 169-2006...

  7. Alamance County, North Carolina ASHRAE 169-2006 Climate Zone...

    Open Energy Info (EERE)

    Alamance County, North Carolina ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Alamance County, North Carolina ASHRAE Standard ASHRAE 169-2006...

  8. Alexander County, North Carolina ASHRAE 169-2006 Climate Zone...

    Open Energy Info (EERE)

    Alexander County, North Carolina ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Alexander County, North Carolina ASHRAE Standard ASHRAE 169-2006...

  9. Central Nevada Seismic Zone Geothermal Region | Open Energy Informatio...

    Open Energy Info (EERE)

    Central Nevada Seismic Zone Geothermal Region Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Central Nevada Seismic Zone Geothermal Region Details Areas (3) Power...

  10. LADOL Integrated Logistics Free Zone Enterprise LILE | Open Energy...

    Open Energy Info (EERE)

    LADOL Integrated Logistics Free Zone Enterprise LILE Jump to: navigation, search Name: LADOL Integrated Logistics Free Zone Enterprise (LILE) Place: Lagos, Nigeria Product:...

  11. Anderson County, Tennessee ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Anderson County, Tennessee ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Anderson County, Tennessee ASHRAE Standard ASHRAE 169-2006 Climate...

  12. Anderson County, South Carolina ASHRAE 169-2006 Climate Zone...

    Open Energy Info (EERE)

    Anderson County, South Carolina ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Anderson County, South Carolina ASHRAE Standard ASHRAE 169-2006...

  13. Baxter County, Arkansas ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Baxter County, Arkansas ASHRAE Standard ASHRAE 169-2006 Climate Zone Number Climate Zone...

  14. Adams County, Colorado ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Adams County, Colorado ASHRAE Standard ASHRAE 169-2006 Climate Zone Number Climate Zone...

  15. As you prepare for your upcoming beam time, please be aware that construction is planned to update SLAC Gate 17 with RFID proximity card access hardware and to change the stairs next to the Security hut to an ADA compliant ramp. Please forward this to your proposal collaborators (and ensure that all users have registered and completed training before they arrive). This construction is scheduled to begin Tuesday 5/28 and be completed by 6/28. During this construction, access to the LCLS and SSRL buildings and experimental facilities will be provided as follows: VEHICLES ONLY THROUGH GATE 17 5/28-6/28 0600-1530 (6 am-3:30 pm) Construction Zone. Only VEHICLE traffic will be allowed access through Gate 17 and flagman will provide traffic control. 1530-1800 (3:30-6:00 pm) Assumes construction will have stopped for the day; both traffic lanes will be open for vehicles. 1800-0600 (6 pm-6 am) As now, Gate 17 will be closed or barricaded overnight. PEDESTRIANS ONLY THROUGH GATE 16 5/28-6/28 The pedestrian turnstile at Gate 16A will not change. The turnstile is available for pedestrian use 24/7 as long as the individual has a valid SLAC ID badge (and there is a guard at Gate 30 to 'buzz' them through). 0700-1600 (6 am-4 pm) Pedestrians who would normally walk through Gate 17 will instead follow the detour to Gate 16 swing gate which will be unlocked and staffed by Security. A valid SLAC ID badge is needed to enter; new users without IDs will be allowed to proceed for check-in and badging after confirmation with the User Research Administration Office (see detour map attached). FYI - After the construction is completed and proximity card readers are fully functional, users and staff will enter Gates 17 and 30 using an activated RFID proximity card. More details to follow.

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Automated Proximity Access at Gate 17 and Sector 30 New SLAC ID badges with embedded RFID are used to activate these gates and for off-hours access at the main entrance off Sand Hill Road as well as Alpine Road (gates will be accessible 24/7) . New user badges include this proximity gate activation feature, but older photo IDs need to be updated. Users are advised to register, complete training and contact the User Research Administration (URA) office before arrival for beam time to help

  16. Measurement of the ratio of the production cross sections times branching fractions of Bc± ? J/??±and B± ? J/? K± and B(Bc±? J/? ?±?±?-/+)/B(Bc± ? J/? ?±) in pp collisions at ?s = 7 TeV

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Khachatryan, V.

    2015-01-13

    The ratio of the production cross sections times branching fractions (?(Bc±) B(Bc± ? J/??±))/(?(B±) B(B± ? J/?K±) is studied in proton-proton collisions at a center-of-mass energy of 7 TeV with the CMS detector at the LHC. The kinematic region investigated requires Ba,sub>c± and B±mesons with transverse momentum p? > 15 GeV and rapidity |y| -1. The ratio is determined to be [0.48 ± 0.05 (stat) ± 0.03(syst) ± 0.05 (?Bc)]% The J/??±?±?-/+ decay mode is also observed in the same data sample. Using a model-independent method developed tomore »measure the efficiency given the presence of resonant behaviour in the three-pion system, the ratio of the branching fractions J/? ?±?±?-/+)/B(Bc± is measured to be 2.55 ± 0.80(stat) ± 0.33(syst) +0.04-0.01 (?Bc), consistent with the previous LHCb result.« less

  17. Table HC9.11 Home Electronics Characteristics by Climate Zone, 2005

    Gasoline and Diesel Fuel Update (EIA)

    11 Home Electronics Characteristics by Climate Zone, 2005 Million U.S. Housing Units Total................................................................... 111.1 10.9 26.1 27.3 24.0 22.8 Personal Computers Do Not Use a Personal Computer ............... 35.5 3.2 8.3 8.9 7.7 7.5 Use a Personal Computer............................. 75.6 7.8 17.8 18.4 16.3 15.3 Number of Desktop PCs 1.............................................................. 50.3 5.1 12.4 11.9 10.5 10.4

  18. Zoned electrical heater arranged in spaced relationship from particulate filter

    DOE Patents [OSTI]

    Gonze, Eugene V [Pinckney, MI

    2011-11-15

    A system comprises a particulate matter (PM) filter that comprises an upstream end for receiving exhaust gas and a downstream end. A zoned heater is arranged spaced from the upstream end and comprises N zones, where N is an integer greater than one, wherein each of the N zones comprises M sub-zones, where M is an integer greater than one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones and deactivates non-selected ones of the N zones.

  19. Innovation and Success in Planning and Zoning | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Planning and Zoning Innovation and Success in Planning and Zoning This document summarizes several successful initiatives to implement solar-friendly planes and zoning codes. PDF icon webinar_072413_planning_zoning.pdf More Documents & Publications webinar_innovation_planning_zoning.doc SunShot Vision Study: February 2012 (Book), SunShot, Energy Efficiency & Renewable Energy (EERE) The SunShot Vision Study

  20. Yucca Mountain Area Saturated Zone Dissolved Organic Carbon Isotopic Data

    SciTech Connect (OSTI)

    Thomas, James; Decker, David; Patterson, Gary; Peterman, Zell; Mihevc, Todd; Larsen, Jessica; Hershey, Ronald

    2007-06-25

    Groundwater samples in the Yucca Mountain area were collected for chemical and isotopic analyses and measurements of water temperature, pH, specific conductivity, and alkalinity were obtained at the well or spring at the time of sampling. For this project, groundwater samples were analyzed for major-ion chemistry, deuterium, oxygen-18, and carbon isotopes of dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC). The U.S. Geological Survey (USGS) performed all the fieldwork on this project including measurement of water chemistry field parameters and sample collection. The major ions dissolved in the groundwater, deuterium, oxygen-18, and carbon isotopes of dissolved inorganic carbon (DIC) were analyzed by the USGS. All preparation and processing of samples for DOC carbon isotopic analyses and geochemical modeling were performed by the Desert Research Institute (DRI). Analysis of the DOC carbon dioxide gas produced at DRI to obtain carbon-13 and carbon-14 values was conducted at the University of Arizona Accelerator Facility (a NSHE Yucca Mountain project QA qualified contract facility). The major-ion chemistry, deuterium, oxygen-18, and carbon isotopes of DIC were used in geochemical modeling (NETPATH) to determine groundwater sources, flow paths, mixing, and ages. The carbon isotopes of DOC were used to calculate groundwater ages that are independent of DIC model corrected carbon-14 ages. The DIC model corrected carbon-14 calculated ages were used to evaluate groundwater travel times for mixtures of water including water beneath Yucca Mountain. When possible, groundwater travel times were calculated for groundwater flow from beneath Yucca Mountain to down gradient sample sites. DOC carbon-14 groundwater ages were also calculated for groundwaters in the Yucca Mountain area. When possible, groundwater travel times were estimated for groundwater flow from beneath Yucca Mountain to down gradient groundwater sample sites using the DOC calculated groundwater ages. The DIC calculated groundwater ages were compared with DOC calculated groundwater ages and both of these ages were compared to travel times developed in ground-water flow and transport models. If nuclear waste is stored in Yucca Mountain, the saturated zone is the final barrier against the release of radionuclides to the environment. The most recent rendition of the TSPA takes little credit for the presence of the saturated zone and is a testament to the inadequate understanding of this important barrier. If radionuclides reach the saturated zone beneath Yucca Mountain, then there is a travel time before they would leave the Yucca Mountain area and flow down gradient to the Amargosa Valley area. Knowing how long it takes groundwater in the saturated zone to flow from beneath Yucca Mountain to down gradient areas is critical information for potential radionuclide transport. Radionuclide transport in groundwater may be the quickest pathway for radionuclides in the proposed Yucca Mountain repository to reach land surface by way of groundwater pumped in Amargosa Valley. An alternative approach to ground-water flow and transport models to determine the travel time of radionuclides from beneath Yucca Mountain to down gradient areas in the saturated zone is by carbon-14 dating of both inorganic and organic carbon dissolved in the groundwater. A standard method of determining ground-water ages is to measure the carbon-13 and carbon-14 of DIC in the groundwater and then correct the measured carbon-14 along a flow path for geochemical reactions that involve carbon containing phases. These geochemical reactions are constrained by carbon-13 and isotopic fractionations. Without correcting for geochemical reactions, the ground-water ages calculated from only the differences in carbon-14 measured along a flow path (assuming the decrease in carbon-14 is due strictly to radioactive decay) could be tens of thousands of years too old. The computer program NETPATH, developed by the USGS, is the best geochemical program for correcting carbon-14 activities for geochemical r

  1. Injectivity Testing for Vapour Dominated Feed Zones

    SciTech Connect (OSTI)

    Clotworthy, A.W.; Hingoyon, C.S.

    1995-01-01

    Wells with vapor dominated feed zones yield abnormal pressure data. This is caused by the condensation of vapor during water injection. A revised injectivity test procedure currently applied by PNOC at the Leyte Geothermal Power Project has improved the injectivity test results.

  2. Climate Zone Number 1 | Open Energy Information

    Open Energy Info (EERE)

    Zone Number 1 is defined as Very Hot - Humid(1A) with IP Units 9000 < CDD50F and SI Units 5000 < CDD10C Dry(1B) with IP Units 9000 < CDD50F and SI Units 5000 < CDD10C...

  3. Archived Reference Climate Zone: 8 Fairbanks, Alaska

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  4. Archived Reference Climate Zone: 8 Fairbanks, Alaska

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  5. Site-Scale Saturated Zone Flow Model

    SciTech Connect (OSTI)

    G. Zyvoloski

    2003-12-17

    The purpose of this model report is to document the components of the site-scale saturated-zone flow model at Yucca Mountain, Nevada, in accordance with administrative procedure (AP)-SIII.lOQ, ''Models''. This report provides validation and confidence in the flow model that was developed for site recommendation (SR) and will be used to provide flow fields in support of the Total Systems Performance Assessment (TSPA) for the License Application. The output from this report provides the flow model used in the ''Site-Scale Saturated Zone Transport'', MDL-NBS-HS-000010 Rev 01 (BSC 2003 [162419]). The Site-Scale Saturated Zone Transport model then provides output to the SZ Transport Abstraction Model (BSC 2003 [164870]). In particular, the output from the SZ site-scale flow model is used to simulate the groundwater flow pathways and radionuclide transport to the accessible environment for use in the TSPA calculations. Since the development and calibration of the saturated-zone flow model, more data have been gathered for use in model validation and confidence building, including new water-level data from Nye County wells, single- and multiple-well hydraulic testing data, and new hydrochemistry data. In addition, a new hydrogeologic framework model (HFM), which incorporates Nye County wells lithology, also provides geologic data for corroboration and confidence in the flow model. The intended use of this work is to provide a flow model that generates flow fields to simulate radionuclide transport in saturated porous rock and alluvium under natural or forced gradient flow conditions. The flow model simulations are completed using the three-dimensional (3-D), finite-element, flow, heat, and transport computer code, FEHM Version (V) 2.20 (software tracking number (STN): 10086-2.20-00; LANL 2003 [161725]). Concurrently, process-level transport model and methodology for calculating radionuclide transport in the saturated zone at Yucca Mountain using FEHM V 2.20 are being carried out in the model report, ''Site-Scale Saturated Zone Transport'', MDL-NBS-HS-000010 Rev 01 (BSC 2003 [162419]). The velocity fields are calculated by the flow model, described herein, independent of the transport processes, and are then used as inputs to the transport model. Justification for this abstraction is presented in the model report, ''Saturated Zone Flow and Transport Model Abstraction'', MDL-NBS-HS-000021 (BSC 2003 [164870]).

  6. Spin waves throughout the Brillouin zone and magnetic exchange coupling in ferromagnetic metallic manganites La$_{1-x}$Ca$_{x}$MnO$_3$ ($x=0.25,0.30$)

    SciTech Connect (OSTI)

    Ye, Feng; Dai, Pengcheng; Fernandez-Baca, Jaime A; Adroja, D. T.; Perring, T. G.; Tomioka, Y.; Tokura, Y.

    2007-01-01

    Using time-of-flight and triple-axis inelastic neutron spectroscopy, we determine spin wave excitations throughout the Brillouin zone for ferromagnetic manganites La$_{1-x}$Ca$_x$MnO$_3$ ($x=0.25,0.3$) in their low temperature metallic states. While spin wave excitations in the long wavelength limit (spin stiffness $D$) have similar values for both compounds, the excitations near the Brillouin zone boundary of La$_{0.7}$Ca$_{0.3}$MnO$_3$ are considerable softened in all symmetry directions compared to that of La$_{0.75}$Ca$_{0.25}$MnO$_3$. A Heisenberg model with the nearest neighbor and the fourth neighbor exchange interactions can describe the overall dispersion curves fairly well. We compare the data with various theoretical models describing the spin excitations of ferromagnetic manganites.

  7. Spin waves throughout the Brillouin zone and magnetic exchange coupling in the ferromagnetic metallic manganites La1−xCaxMnO3 (x=0.25, 0.30)

    SciTech Connect (OSTI)

    Ye, Feng; Dai, Pengcheng; Fernandez-Baca, Jaime A; Adroja, D. T.; Perring, T. G.; Tomioka, Y.; Tokura, Y.

    2007-01-01

    Using time-of-flight and triple-axis inelastic neutron spectroscopy, we determine spin-wave excitations throughout the Brillouin zone for ferromagnetic manganites La1−xCaxMnO3 (x=0.25, 0.3) in their lowtemperature metallic states. While spin-wave excitations in the long-wavelength limit spin stiffness D have similar values for both compounds, the excitations near the Brillouin-zone boundary of La0.7Ca0.3MnO3 are considerably softened in all symmetry directions compared to that of La0.75Ca0.25MnO3. A Heisenberg model with the nearest neighbor and the fourth neighbor exchange interactions can describe the overall dispersion curves fairly well. We compare the data with various theoretical models describing the spin excitations of ferromagnetic manganites.

  8. High exhaust temperature, zoned, electrically-heated particulate matter filter

    DOE Patents [OSTI]

    Gonze, Eugene V.; Paratore, Jr., Michael J.; Bhatia, Garima

    2015-09-22

    A system includes a particulate matter (PM) filter, an electric heater, and a control circuit. The electric heater includes multiple zones, which each correspond to longitudinal zones along a length of the PM filter. A first zone includes multiple discontinuous sub-zones. The control circuit determines whether regeneration is needed based on an estimated level of loading of the PM filter and an exhaust flow rate. In response to a determination that regeneration is needed, the control circuit: controls an operating parameter of an engine to increase an exhaust temperature to a first temperature during a first period; after the first period, activates the first zone; deactivates the first zone in response to a minimum filter face temperature being reached; subsequent to deactivating the first zone, activates a second zone; and deactivates the second zone in response to the minimum filter face temperature being reached.

  9. Lecture 7

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7.12 shows the structure of a stoichiometric methane-air flame, computed using the GRI-Mech 3.0 (G. P. Smith, D. M. Golden, M. Frenklach, N. W. Moriarty, B. Eiteneer, M....

  10. Amendment 7

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 Date: March 13, 2008 ISSUED BY: National Renewable Energy Laboratory 1617 Cole Blvd. Golden, CO 80401-3393 PROJECT NAME & LOCATION DesignBuild Subcontract for the Research...

  11. CHAPTER 7

    Energy Savers [EERE]

    December 2014 7-1 CHAPTER 7 ADVANCES, PREPAID EXPENSES, AND OTHER ASSETS 1. INTRODUCTION Purpose and Scope. The Chapter discusses the accounting treatment and financial controls for advances, prepaid expenses, and other assets. This chapter should not be used as a reference for determining whether it is appropriate to make an advance payment or prepay expenses, but it does provide references to the appropriate criteria for making that determination. This chapter supplements the Treasury

  12. ARM - Time in ARM NetCDF Files

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    govDataTime in ARM NetCDF Files Page Contents Introduction Time Zones Epoch Time Time Variables Conversion Examples and Hints Perl Example C Example Fortran Example IDL Example Notes on Generating Epoch Times Contact Information Time in ARM NetCDF Files Introduction This document explains most of the issues related to the use of time in ARM netCDF data files. Time Zones All ARM netCDF files are in UTC. Note that this has some implications for solar-based data; we tend to split our files at

  13. Analysis of offsite emergency planning zones project

    SciTech Connect (OSTI)

    Petrocchi, A.J.; Armstrong, C.E. . Rocky Flats Plant); McKinney, J.M.; Verholek, M.G.; Fraser, P.J.; Dalfonso, P.H. )

    1991-07-18

    The Rocky Flats Plant maintains and uses significant nonradioactive chemically hazardous material (HAZMAT) inventories. Some of these materials are used in sufficient quantities to represent a credible risk to the offsite public in the event of an emergency at the facility. In Phase 2 of this project, the EG G Rocky Flats, Inc. and TENERA, L.P. Task Team (Task Team) produced an initial screening-level modeling analysis study and an Emergency Planning Zone (EPZ) encompassing the Vulnerable Zones (VZs) for hazardous materials stored at the facility. The screening-level analysis will be supplemented with more refined evaluations during subsequent phases of the project. The existence of these chemicals in the Rocky Flats Plant Occupational Health Information System (OHIS) chemical inventory database was verified. All liquid and gaseous chemicals were considered as potential hazardous material source terms for further screening analysis. Hazards associated with solid substances were not considered in this phase of the project. 2 figs., 13 tabs.

  14. Capillary zone electrophoresis-mass spectrometer interface

    DOE Patents [OSTI]

    D`Silva, A.

    1996-08-06

    A device for providing equal electrical potential between two loci unconnected by solid or liquid electrical conductors is provided. The device comprises a first electrical conducting terminal, a second electrical conducting terminal connected to the first terminal by a rigid dielectric structure, and an electrically conducting gas contacting the first and second terminals. This device is particularly suitable for application in the electrospray ionization interface between a capillary zone electrophoresis apparatus and a mass spectrometer. 1 fig.

  15. Diesel particulate filter with zoned resistive heater

    DOE Patents [OSTI]

    Gonze, Eugene V [Pinckney, MI

    2011-03-08

    A diesel particulate filter assembly comprises a diesel particulate filter (DPF) and a heater assembly. The DPF filters a particulate from exhaust produced by an engine. The heater assembly has a first metallic layer that is applied to the DPF, a resistive layer that is applied to the first metallic layer, and a second metallic layer that is applied to the resistive layer. The second metallic layer is etched to form a plurality of zones.

  16. June 7

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 June 7 Attending: Eric, Jay and Katie from NERSC and users Andrei, Jeff A. and Jeff P. Utilization: Cluster tends to be running at about 50% of capacity on average the past month. Recent Downtimes/Outages: 6/1: SWO for most of the day: /home migration to new hardware was completed, updated BestMan on pdsfdtn1. This upgrade will hopefully address some timeout bug that had affected STAR transfers. Upcoming Downtimes: No clusterwide outages planned but eliza3 needs a reboot. This shouldn't

  17. Archive Reference Buildings by Climate Zone: 3A Atlanta, Georgia...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Archive Reference Buildings by Climate Zone: 3A Atlanta, Georgia Archive Reference Buildings by Climate Zone: 3A Atlanta, Georgia Here you will find past versions of the reference ...

  18. Gulf of California Rift Zone Geothermal Region | Open Energy...

    Open Energy Info (EERE)

    Projects (0) Techniques (0) Map: Name The Gulf of California rift zone is a complex transition zone between the dextral (right-lateral) motion of the San Andreas transform...

  19. Time Off

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Time Off Time Off A comprehensive benefits package with plan options for health care and retirement to take care of our employees today and tomorrow. Contact Benefits Office (505)...

  20. Formation of the compression zone in a plasma flow generated by a magnetoplasma compressor

    SciTech Connect (OSTI)

    Solyakov, D. G. Petrov, Yu. V.; Garkusha, I. E.; Chebotarev, V. V.; Ladygina, M. S.; Cherednichenko, T. N.; Morgal’, Ya. I.; Kulik, N. V.; Stal’tsov, V. V.; Eliseev, D. V.

    2013-12-15

    Processes occurring in a plasma flow generated by a magnetoplasma compressor (MPC) during the formation of the compression zone are discussed. The paper presents results of measurements of the spatial distribution of the electric current in the plasma flow, the temporal and spatial (along the flow) distributions of the plasma density, and the profiles of the velocity of individual flow layers along the system axis. The spatial distribution of the electromagnetic force in the flow is analyzed. It is shown that the plasma flow is decelerated when approaching the compression zone and reaccelerated after passing it. In this case, the plasma flow velocity decreases from ? = (2–3) Ś 10{sup 7} cm/s at the MPC output to ? < 10{sup 6} cm/s in the region of maximum compression and then again increases to 10{sup 7} cm/s at a distance of 15–17 cm from the MPC output. In some MPC operating modes, a displacement of the magnetic field from the compression zone and the formation of toroidal electric current vortices in the plasma flow after passing the compression zone were detected.

  1. Alleghanian development of the Goat Rock fault zone, southernmost Appalachians: Temporal compatibility with the master decollement

    SciTech Connect (OSTI)

    Steltenpohl, M.G. (Auburn Univ., AL (United States)); Goldberg, S.A. (Univ. of North Carolina, Chapel Hill (United States)); Hanley, T.B. (Columbus College, GA (United States)); Kunk, M.J. (Geological Survey, Reston, VA (United States))

    1992-09-01

    The Goat Rock and associated Bartletts Ferry fault zones, which mark the eastern margin of the Pine Mountain Grenville basement massif, are controversial due to the suggestion that they are rare exposed segments of the late Paleozoic southern Appalachian master decollement. The controversy in part stems from reported middle Paleozoic (Acadian) radiometric dates postulated as the time of movement along these fault zones. Ultramylonite samples from the type area at Goat Rock Dam yield a 287 [plus minus] 15 Ma Rb-Sr isochron interpreted as the time of Sr isotopic rehomgenization during mylonitization. This date is corroborated by Late Pennsylvanian-Early Permian [sup 40]Ar/[sup 39]Ar mineral ages on hornblende (297-288 Ma) and muscovite (285-278 Ma) from neomineralized and dynamically recrystallized rocks within and straddling the fault zone. These Late Pennsylvanian-Early Permian dates indicate the time of right-slip movement (Alleghenian) along the Goat Rock fault zone, which is compatible with the timing suggested by COCORP for thrusting along the southern Appalachian master decollement.

  2. SATURATED ZONE IN-SITU TESTING

    SciTech Connect (OSTI)

    P.W. REIMUS

    2004-11-08

    The purpose of this scientific analysis is to document the results and interpretations of field experiments that test and validate conceptual flow and radionuclide transport models in the saturated zone (SZ) near Yucca Mountain, Nevada. The test interpretations provide estimates of flow and transport parameters used in the development of parameter distributions for total system performance assessment (TSPA) calculations. These parameter distributions are documented in ''Site-Scale Saturated Zone Flow Model (BSC 2004 [DIRS 170037]), Site-Scale Saturated Zone Transport'' (BSC 2004 [DIRS 170036]), Saturated Zone Colloid Transport (BSC 2004 [DIRS 170006]), and ''Saturated Zone Flow and Transport Model Abstraction'' (BSC 2004 [DIRS 170042]). Specifically, this scientific analysis contributes the following to the assessment of the capability of the SZ to serve as part of a natural barrier for waste isolation for the Yucca Mountain repository system: (1) The bases for selection of conceptual flow and transport models in the saturated volcanics and the saturated alluvium located near Yucca Mountain. (2) Results and interpretations of hydraulic and tracer tests conducted in saturated fractured volcanics at the C-wells complex near Yucca Mountain. The test interpretations include estimates of hydraulic conductivities, anisotropy in hydraulic conductivity, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, matrix diffusion coefficients, fracture apertures, and colloid transport parameters. (3) Results and interpretations of hydraulic and tracer tests conducted in saturated alluvium at the Alluvial Testing Complex (ATC) located at the southwestern corner of the Nevada Test Site (NTS). The test interpretations include estimates of hydraulic conductivities, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, and colloid transport parameters. (4) Comparisons of sorption parameter estimates for a reactive solute tracer (lithium ion) derived from the C-wells field tracer tests and laboratory tests using C-wells core samples. (5) Sorption parameter estimates for lithium ion derived from laboratory tests using alluvium samples from ATC well NC-EWDP-19D. These estimates will allow a comparison of laboratory- and field-derived sorption parameters to be made in saturated alluvium if cross-hole tracer tests are conducted at the ATC.

  3. Modeling-Computer Simulations At Central Nevada Seismic Zone...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Modeling-Computer Simulations At Central Nevada Seismic Zone Region (Pritchett, 2004) Exploration...

  4. Turkey Near-Zero Zone | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Turkey Near-Zero Zone Turkey Near-Zero Zone The U.S. Department of Energy and Turkey's Ministry of Energy, with interagency support from the U.S. Trade and Development Agency, the Overseas Private Investment Corporation and the State Department, developed the Near-Zero Zone (NZZ) - an industrial energy efficiency project at the Ataturk Organized Industrial Zone in Izmir, Turkey. NZZ was designed to reduce Turkey's dependence on energy imports, bolster energy security, cut carbon emissions, and

  5. Development of Characterization Technology for Fault Zone Hydrology

    SciTech Connect (OSTI)

    Karasaki, Kenzi; Onishi, Tiemi; Gasperikova, Erika; Goto, Junichi; Tsuchi, Hiroyuki; Miwa, Tadashi; Ueta, Keiichi; Kiho, Kenzo; MIyakawa, Kimio

    2010-08-06

    Several deep trenches were cut, and a number of geophysical surveys were conducted across the Wildcat Fault in the hills east of Berkeley, California. The Wildcat Fault is believed to be a strike-slip fault and a member of the Hayward Fault System, with over 10 km of displacement. So far, three boreholes of ~;; 150m deep have been core-drilled and borehole geophysical logs were conducted. The rocks are extensively sheared and fractured; gouges were observed at several depths and a thick cataclasitic zone was also observed. While confirming some earlier, published conclusions from shallow observations about Wildcat, some unexpected findings were encountered. Preliminary analysis indicates that Wildcat near the field site consists of multiple faults. The hydraulic test data suggest the dual properties of the hydrologic structure of the fault zone. A fourth borehole is planned to penetrate the main fault believed to lie in-between the holes. The main philosophy behind our approach for the hydrologic characterization of such a complex fractured system is to let the system take its own average and monitor a long term behavior instead of collecting a multitude of data at small length and time scales, or at a discrete fracture scale and to ?up-scale,? which is extremely tenuous.

  6. Vadose Zone Characterization Techniques Developed by EMSP Research

    SciTech Connect (OSTI)

    Guillen, Donna P.

    2003-02-24

    This paper discusses research contributions made by Environmental Management Science Program (EMSP) research in the area of geophysical characterization of the subsurface. The goal of these EMSP research projects is to develop combined high-resolution measurement and interpretation packages that provide accurate, timely information needed to characterize the vadose zone. Various types of geophysical imaging techniques can be used to characterize the shallow subsurface. Since individual geophysical characterization tools all have specific limitations, many different techniques are being explored to provide more widespread applicability over a range of hydrogeologic settings. A combination of laboratory, field, theoretical, and computational studies are necessary to develop our understanding of how contaminants move through the vadose zone. This entails field tests with field-hardened systems, packaging and calibration of instrumentation, data processing and analysis algorithms, forward and inverse modeling, and so forth. DOE sites are seeking to team with EMSP researchers to leverage the basic science research investment and apply these advances to address subsurface contamination issues that plague many U.S. Department of Energy (DOE) sites.

  7. Zoning for Distributed Wind Power - Breaking Down Barriers: Preprint

    SciTech Connect (OSTI)

    Green, J.; Sagrillo, M.

    2005-08-01

    Zoning regulations for the use of small wind turbines vary from state to state and from one local jurisdiction to the next. This paper examines the zoning experiences of small wind turbine owners, options for local actions, and examples of state and federal limited preemption of local zoning authority as a means of promoting the implementation of new technologies.

  8. Multi-Zone Modeling of the Pulsar Win Nebula HESS J1825-137

    SciTech Connect (OSTI)

    Van Etten, Adam; Romani, Roger W.; /Stanford U., Phys. Dept.

    2011-11-08

    The pulsar wind nebula associated with PSR J1826-1334, HESS J1825-137, is a bright very high energy source with an angular extent of {approx} 1{sup o} and spatially-resolved spectroscopic TeV measurements. The gamma-ray spectral index is observed to soften with increasing distance from the pulsar, likely the result of cooling losses as electrons traverse the nebula. We describe analysis of X-ray data of the extended nebula, as well as 3-D time-dependent spectral energy distribution modeling, with emphasis on the spatial variations within HESS J1825-137. The multi-wavelength data places significant constraints on electron injection, transport, and cooling within the nebula. The large size and high nebular energy budget imply a relatively rapid initial pulsar spin period of 13 {+-} 7 ms and an age of 40 {+-} 9 kyr. The relative fluxes of each VHE zone can be explained by advective particle transport with a radially decreasing velocity profile with v(r) {proportional_to} r{sup -0.5}. The evolution of the cooling break requires an evolving magnetic field which also decreases radially from the pulsar, B(r, t) {proportional_to} r{sup -0.7} E(t){sup 1/2}. Detection of 10 TeV flux {approx} 80 pc from the pulsar requires rapid diffusion of high energy particles with {tau}{sub esc} {approx} 90 (R/10 pc){sup 2}(E{sub e}/100TeV){sup -1} year, contrary to the common assumption of toroidal magnetic fields with strong magnetic confinement. The model predicts a rather uniform Fermi LAT surface brightness out to {approx} 1{sup o} from the pulsar, in good agreement with the recently discovered LAT source centered 0.5{sup o} southwest of PSR J1826-1334 with extension 0.6 {+-} 0.1{sup o}.

  9. Table 7

    Gasoline and Diesel Fuel Update (EIA)

    1 Table 7 Created on: 2/24/2016 8:11:36 AM Table 7. Marketed production of natural gas in selected states and the Federal Gulf of Mexico, 2010-2015 (million cubic feet) Year and Month Alaska Arkansas California Colorado Kansas Louisiana Montana New Mexico North Dakota Ohio 2010 Total 374,226 926,639 286,841 1,578,379 324,720 2,210,099 87,539 1,292,185 81,837 78,122 2011 Total 356,225 1,072,212 250,177 1,637,576 309,124 3,029,206 74,624 1,237,303 97,102 78,858 2012 Total 351,259 1,146,168 246,822

  10. December 7

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Eric, Katie and Jay from NERSC and users Andrei, Yushu, Thomas, Jeff P., Craig, Joanna Cluster status: Cluster has been full most of the time and is full today. STAR and ALICE...

  11. Table HC1-1a. Housing Unit Characteristics by Climate Zone,

    Gasoline and Diesel Fuel Update (EIA)

    a. Housing Unit Characteristics by Climate Zone, Million U.S. Households, 2001 Housing Unit Characteristics RSE Column Factor: Total Climate Zone 1 RSE Row Factors Fewer than 2,000 CDD and -- 2,000 CDD or More and Fewer than 4,000 HDD More than 7,000 HDD 5,500 to 7,000 HDD 4,000 to 5,499 HDD Fewer than 4,000 HDD 0.4 1.8 1.0 1.1 1.2 1.1 Total ............................................... 107.0 9.2 28.6 24.0 21.0 24.1 8.0 Census Region and Division Northeast

  12. "Table HC9.10 Home Appliances Usage Indicators by Climate Zone, 2005"

    U.S. Energy Information Administration (EIA) Indexed Site

    0 Home Appliances Usage Indicators by Climate Zone, 2005" " Million U.S. Housing Units" ,,"Climate Zone1" ,,"Less than 2,000 CDD and --",,,,"2,000 CDD or More and Less than 4,000 HDD" ,"Housing Units (millions)" ,,"Greater than 7,000 HDD","5,500 to 7,000 HDD","4,000 to 5,499 HDD","Less than 4,000 HDD" "Home Appliances Characteristics" "Total",111.1,10.9,26.1,27.3,24,22.8

  13. Adams County, Wisconsin ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Adams County, Wisconsin ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Adams County, Wisconsin ASHRAE Standard ASHRAE 169-2006 Climate Zone...

  14. Anderson County, Kansas ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Anderson County, Kansas ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Anderson County, Kansas ASHRAE Standard ASHRAE 169-2006 Climate Zone...

  15. Seismological investigation of earthquakes in the New Madrid Seismic Zone. Final report, September 1986--December 1992

    SciTech Connect (OSTI)

    Herrmann, R.B.; Nguyen, B.

    1993-08-01

    Earthquake activity in the New Madrid Seismic Zone had been monitored by regional seismic networks since 1975. During this time period, over 3,700 earthquakes have been located within the region bounded by latitudes 35{degrees}--39{degrees}N and longitudes 87{degrees}--92{degrees}W. Most of these earthquakes occur within a 1.5{degrees} x 2{degrees} zone centered on the Missouri Bootheel. Source parameters of larger earthquakes in the zone and in eastern North America are determined using surface-wave spectral amplitudes and broadband waveforms for the purpose of determining the focal mechanism, source depth and seismic moment. Waveform modeling of broadband data is shown to be a powerful tool in defining these source parameters when used complementary with regional seismic network data, and in addition, in verifying the correctness of previously published focal mechanism solutions.

  16. Variable residence time vortex combustor

    DOE Patents [OSTI]

    Melconian, Jerry O.

    1987-01-01

    A variable residence time vortex combustor including a primary combustion chamber for containing a combustion vortex, and a plurality of louvres peripherally disposed about the primary combustion chamber and longitudinally distributed along its primary axis. The louvres are inclined to impel air about the primary combustion chamber to cool its interior surfaces and to impel air inwardly to assist in driving the combustion vortex in a first rotational direction and to feed combustion in the primary combustion chamber. The vortex combustor also includes a second combustion chamber having a secondary zone and a narrowed waist region in the primary combustion chamber interconnecting the output of the primary combustion chamber with the secondary zone for passing only lower density particles and trapping higher density particles in the combustion vortex in the primary combustion chamber for substantial combustion.

  17. Moq--7

    Office of Legacy Management (LM)

    - .A. Moq--7 . ) >C\ * \ : ' 4 T!iTERIM PzPxi lUDIc:LOGICAL SURVEY OF THE PRCFERTY .' .T 92CC LAY-i-Y AVEXIJE, li.~ZEL~v00D, MISSOURI 2. 14'. Legget: P. T. ? ercixe F. F. iiayood .h:* T. Ryar: E. ii. h;zgner c. J. Sarton hiork performed by Health and Safety Research Division 022 Ridge Nztional Laboratop Oak Ridge, Tennessee 37550 September 1977 for the DEPAR'NE.hY' OF E?lERGY as p2it 01 The Radiological Surveys of Former Mariiatran Engineering Districtj Atomic EnerE Comuiission Sites DOE _..-

  18. Quasiparticle dynamics across the full Brillouin zone of Bi2Sr2CaCu2O8+ÎŽ

    Office of Scientific and Technical Information (OSTI)

    traced with ultrafast time and angle-resolved photoemission spectroscopy (Journal Article) | SciTech Connect Quasiparticle dynamics across the full Brillouin zone of Bi2Sr2CaCu2O8+ÎŽ traced with ultrafast time and angle-resolved photoemission spectroscopy Citation Details In-Document Search Title: Quasiparticle dynamics across the full Brillouin zone of Bi2Sr2CaCu2O8+ÎŽ traced with ultrafast time and angle-resolved photoemission spectroscopy A hallmark in the cuprate family of

  19. X Time Series

    Energy Savers [EERE]

    11 Figure 5-11: 1-Hour Ozone Time Series Observed (C506) v. Predicted (CAMx) for WRF AACOG Base Case Run 3, 2006 5-12 5.3.2 Hourly NO X Time Series Time series plots of modeled and predicted hourly NO X for each monitor located in the San Antonio MSA were constructed. The model over predicted NO X emissions at the C58 monitor on almost every day during the June 2006 episode. The average predicted hourly NO X was 7.3 ppb, while the average observed hourly NO X was only 3.9 ppb. Likewise, the

  20. Table HC9.4 Space Heating Characteristics by Climate Zone, 2005

    Gasoline and Diesel Fuel Update (EIA)

    4 Space Heating Characteristics by Climate Zone, 2005 Million U.S. Housing Units Total......................................................................... 111.1 10.9 26.1 27.3 24.0 22.8 Do Not Have Space Heating Equipment................ 1.2 Q Q N 0.3 0.8 Have Main Space Heating Equipment.................... 109.8 10.9 26.0 27.3 23.7 22.0 Use Main Space Heating Equipment..................... 109.1 10.9 26.0 27.3 23.2 21.7 Have Equipment But Do Not Use It........................ 0.8 N N Q

  1. Anderson County, Texas ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Anderson County, Texas ASHRAE Standard ASHRAE 169-2006 Climate Zone Number Climate Zone Number...

  2. DEAD, UNDEAD, AND ZOMBIE ZONES IN PROTOSTELLAR DISKS AS A FUNCTION OF STELLAR MASS

    SciTech Connect (OSTI)

    Mohanty, Subhanjoy; Ercolano, Barbara; Turner, Neal J. E-mail: ercolano@usm.lmu.de

    2013-02-10

    We investigate the viability of the magnetorotational instability (MRI) in X-ray ionized viscous accretion disks around both solar-type stars and very low mass stars. In particular, we determine the disk regions where the MRI can be shut off either by Ohmic resistivity (the so-called dead and undead zones) or by ambipolar diffusion (a region we term the zombie zone). We consider two stellar masses: M {sub *} = 0.7 M {sub Sun} and 0.1 M {sub Sun }. In each case, we assume that: the disk surface density profile is that of a scaled Minimum Mass Solar Nebula, with M {sub disk}/M {sub *} = 0.01 as suggested by current data; disk ionization is driven primarily by stellar X-rays, complemented by cosmic rays and radionuclides; and the stellar X-ray luminosity scales with bolometric luminosity as L{sub X} /L {sub *} Almost-Equal-To 10{sup -3.5}, as observed. Ionization rates are calculated with the MOCCASIN Monte Carlo X-ray transport code, and ionization balance determined using a simplified chemical network, including well-mixed 0.1 {mu}m grains at various levels of depletion. We find that (1) ambipolar diffusion is the primary factor controlling MRI activity in disks around both solar-type and very low mass classical T Tauri stars. Assuming that the MRI yields the maximum possible field strength at each radius, we further find that: (2) the MRI-active layer constitutes only {approx}5%-10% of the total disk mass; (3) the accretion rate ( M-dot ) varies radially in both magnitude and sign (inward or outward), implying time-variable accretion as well as the creation of disk gaps and overdensities, with consequences for planet formation and migration; (4) achieving the empirical accretion rates in solar-type and very low mass stars requires a depletion of well-mixed small grains (via grain growth and/or settling) by a factor of 10-1000 relative to the standard dust-to-gas mass ratio of 10{sup -2}; and (5) the current non-detection of polarized emission from field-aligned grains in the outer disk regions is consistent with active MRI at those radii.

  3. Tank 241-AX-104 upper vadose zone cone penetrometer demonstration sampling and analysis plan

    SciTech Connect (OSTI)

    FIELD, J.G.

    1999-02-02

    This sampling and analysis plan (SAP) is the primary document describing field and laboratory activities and requirements for the tank 241-AX-104 upper vadose zone cone penetrometer (CP) demonstration. It is written in accordance with Hanford Tank Initiative Tank 241-AX-104 Upper Vadose Zone Demonstration Data Quality Objective (Banning 1999). This technology demonstration, to be conducted at tank 241-AX-104, is being performed by the Hanford Tanks Initiative (HTI) Project as a part of Tank Waste Remediation System (TWRS) Retrieval Program (EM-30) and the Office of Science and Technology (EM-50) Tanks Focus Area. Sample results obtained as part of this demonstration will provide additional information for subsequent revisions to the Retrieval Performance Evaluation (RPE) report (Jacobs 1998). The RPE Report is the result of an evaluation of a single tank farm (AX Tank Farm) used as the basis for demonstrating a methodology for developing the data and analyses necessary to support making tank waste retrieval decisions within the context of tank farm closure requirements. The RPE includes a study of vadose zone contaminant transport mechanisms, including analysis of projected tank leak characteristics, hydrogeologic characteristics of tank farm soils, and the observed distribution of contaminants in the vadose zone in the tank farms. With limited characterization information available, large uncertainties exist as to the nature and extent of contaminants that may exist in the upper vadose zone in the AX Tank Farm. Traditionally, data has been collected from soils in the vadose zone through the installation of boreholes and wells. Soil samples are collected as the bore hole is advanced and samples are screened on site and/or sent to a laboratory for analysis. Some in-situ geophysical methods of contaminant analysis can be used to evaluate radionuclide levels in the soils adjacent to an existing borehole. However, geophysical methods require compensation for well casing interference and soil moisture content and may not be successful in some conditions. In some cases the level of interference must be estimated due to uncertainties regarding the materials used in well construction and soil conditions, Well casing deployment used for many in-situ geophysical methods is relatively expensive and geophysical methods do not generally provide real time values for contaminants. In addition, some of these methods are not practical within the boundaries of the tank farm due to physical constraints, such as underground piping and other hardware. The CP technologies could facilitate future characterization of vadose zone soils by providing vadose zone data in near real-time, reducing the number of soil samples and boreholes required, and reducing characterization costs.

  4. EVALUATION OF VADOSE ZONE TREATMENT TECHNOLOGIES TO IMMOBILIZE TECHNETIUM-99

    SciTech Connect (OSTI)

    PETERSEN, S.W.

    2006-03-15

    The Hanford Site End State Vision document (DOE/RL-2003-59) states: ''There should be an aggressive plan to develop technology for remediation of the contamination that could get to the groundwater (particularly the technetium [{sup 99}Tc])''. In addition, there is strong support from the public and regulatory agencies for the above statement, with emphasis on investigation of treatment alternatives. In July 2004, PNNL completed a preliminary evaluation of remediation technologies with respect to their effectiveness and implementability for immobilization of {sup 99}Tc beneath the BC Cribs in the 200 West Area (Truex, 2004). As a result of this evaluation, PNNL recommended treatability testing of in situ soil desiccation, because it has the least uncertainty of those technologies evaluated in July 2004 (Treatability Test Outline, September 30, 2004). In 2005, DOE-RL and Fluor Hanford convened an independent technical panel to review alternative remediation technologies, including desiccation, at a three-day workshop in Richland, Washington. The panel was composed of experts in vadose-zone transport, infiltration control, hydrology, geochemistry, environmental engineering, and geology. Their backgrounds include employment in academia, government laboratories, industry, and consulting. Their review, presented in this document, is based upon written reports from Hanford, oral presentations from Hanford staff, and each panel members' years of experience in their particular field of expertise. The purpose of this report is to document the panel's evaluation of various treatment alternatives with potential for minimizing contaminant migration in the deep vadose zone at the Department of Energy Hanford Site. The panel was tasked with assessing the most viable and practical approach and making recommendations for testing. The evaluation of vadose-zone treatment alternatives was conducted to be broadly applicable at a variety of locations at Hanford. However, because of limitations of time, the panel was asked to focus on one example, {sup 99}Tc contamination below the BC Cribs and Trenches. It is well recognized that conditions at BC Cribs and Trenches are not the same as those at other Hanford locations, but it was selected so that the panel could develop an understanding of site conditions at one location. The recommendations in this report are not intended to address the regulatory decision process for this site.

  5. Webinar: EISPC Energy Zones Mapping Tool Demonstration | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Webinar: EISPC Energy Zones Mapping Tool Demonstration Webinar: EISPC Energy Zones Mapping Tool Demonstration June 23, 2014 - 10:40am Addthis Argonne National Laboratory has organized a webinar demonstration of the Eastern Interconnection States' Planning Council (EISPC) Energy Zones (EZ) Mapping Tool, a free online mapping tool for identifying areas in all 39 EISPC states that may be suitable for new clean power generation. The tool is maintained by Argonne National Laboratory with

  6. Central Plateau Groundwater and Deep Vadose Zone Strategy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Vadose Zone Executive Council Hanford Advisory Board River and Plateau Committee Briant L. Charboneau DOE-RL, Soil and Groundwater Federal Project Director October 9, 2012 1 Discussion Topics * Purpose of the Executive Council - Why was this established? * Who participates? * What are the integration topics of interest to the Council? * Examples of groundwater and vadose zone integration - Deep Vadose Zone treatability testing leading to evaluation of measures to protect groundwater - B complex

  7. Eastern Energy Zones Mapping Tool | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Eastern Energy Zones Mapping Tool Eastern Energy Zones Mapping Tool The Eastern Interconnection States' Planning Council (EISPC) has released the Energy Zones (EZ) Mapping Tool, a free, web-based interactive tool that will help states and other stakeholders in the Eastern Interconnection identify geographic areas suitable for the development of clean energy resources (natural gas, sequestration or utilitization locations for C02 from coal, nuclear, and renewable) which can potentially provide

  8. Eastern Energy Zones Mapping Tool Now Available | Department of Energy

    Office of Environmental Management (EM)

    Eastern Energy Zones Mapping Tool Now Available Eastern Energy Zones Mapping Tool Now Available May 3, 2013 - 12:08pm Addthis The Eastern Interconnection States' Planning Council (EISPC) has released the Energy Zones (EZ) Mapping Tool, a free, web-based interactive tool that will help states and other stakeholders in the Eastern Interconnection identify geographic areas suitable for the development of clean energy resources (natural gas, sequestration or utilitization locations for C02 from

  9. Geothermal Literature Review At Walker-Lane Transitional Zone...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Geothermal Literature Review At Walker-Lane Transitional Zone Region (Laney, 2005) Exploration Activity...

  10. Gradient zone boundary control in salt gradient solar ponds

    DOE Patents [OSTI]

    Hull, John R.

    1984-01-01

    A method and apparatus for suppressing zone boundary migration in a salt gradient solar pond includes extending perforated membranes across the pond at the boundaries, between the convective and non-convective zones, the perforations being small enough in size to prevent individual turbulence disturbances from penetrating the hole, but being large enough to allow easy molecular diffusion of salt thereby preventing the formation of convective zones in the gradient layer. The total area of the perforations is a sizable fraction of the membrane area to allow sufficient salt diffusion while preventing turbulent entrainment into the gradient zone.

  11. Compound and Elemental Analysis At Central Nevada Seismic Zone...

    Open Energy Info (EERE)

    Nevada Seismic Zone Geothermal Region Exploration Technique Compound and Elemental Analysis Activity Date Usefulness not indicated DOE-funding Unknown Notes Geochemical...

  12. Isotopic Analysis At Central Nevada Seismic Zone Region (Laney...

    Open Energy Info (EERE)

    Location Central Nevada Seismic Zone Geothermal Region Exploration Technique Isotopic Analysis- Fluid Activity Date Usefulness not indicated DOE-funding Unknown Notes...

  13. Tectonic analysis of the Rio Grande Rift Zone, central Colorado...

    Open Energy Info (EERE)

    Rift Zone, central ColoradoThesisDissertation Abstract Abstract unavailable. Author D.H. Knepper Organization Colorado School of Mines Published Publisher Not Provided, 1974...

  14. Field Mapping At Central Nevada Seismic Zone Region (Blewitt...

    Open Energy Info (EERE)

    to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Field Mapping At Central Nevada Seismic Zone Region (Blewitt Et Al, 2005) Exploration Activity...

  15. Baltimore County, Maryland ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Baltimore County, Maryland ASHRAE 169-2006 Climate Zone Jump to: navigation, search County...

  16. Baltimore City County, Maryland ASHRAE 169-2006 Climate Zone...

    Open Energy Info (EERE)

    Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Baltimore City County, Maryland ASHRAE 169-2006 Climate Zone Jump to: navigation, search...

  17. Washington Coastal Zone Management Webpage | Open Energy Information

    Open Energy Info (EERE)

    Webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Washington Coastal Zone Management Webpage Abstract Provides overview of Washington's coastal...

  18. Community Wind Handbook/Understand Permitting & Zoning | Open...

    Open Energy Info (EERE)

    Permitting & Zoning < Community Wind Handbook Jump to: navigation, search WIND ENERGY STAKEHOLDER ENGAGEMENT & OUTREACHCommunity Wind Handbook WindTurbine-icon.png...

  19. Water Sampling At Central Nevada Seismic Zone Region (Laney,...

    Open Energy Info (EERE)

    Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Water Sampling At Central Nevada Seismic Zone Region (Laney, 2005) Exploration Activity...

  20. Water Sampling At Walker-Lane Transitional Zone Region (Laney...

    Open Energy Info (EERE)

    Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Water Sampling At Walker-Lane Transitional Zone Region (Laney, 2005) Exploration Activity...

  1. EPA Coastal Zone Act Reauthorization Amendments (CZARA) Section...

    Open Energy Info (EERE)

    Section 6217 Webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: EPA Coastal Zone Act Reauthorization Amendments (CZARA) Section 6217 Webpage...

  2. AltaRock Energy Announces Successful Multiple-Zone Stimulation...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Stimulation of Well at the Newberry Enhanced Geothermal Systems Demonstration AltaRock Energy Announces Successful Multiple-Zone Stimulation of Well at the Newberry ...

  3. Drone Zone at Los Alamos ScienceFest

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Drone Zone at Los Alamos ScienceFest Drone Zone at Los Alamos ScienceFest WHEN: Jul 18, 2015 11:00 AM - 3:00 PM WHERE: Ashley Pond Downtown Los Alamos, New Mexico CONTACT: Jessica Privette 505 667-0375 CATEGORY: Bradbury INTERNAL: Calendar Login Drone Zone at Los Alamos ScienceFest Event Description An interactive event offering learning and competition as part of the Los Alamos ScienceFest. Join us at the Drone Zone at Los Alamos ScienceFest where you can bring your own drone or try flying a

  4. Data Acquisition-Manipulation At Central Nevada Seismic Zone...

    Open Energy Info (EERE)

    - 2) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Data Acquisition-Manipulation At Central Nevada Seismic Zone Region (Coolbaugh, Et Al., 2005...

  5. Walker-Lane Transition Zone Geothermal Region | Open Energy Informatio...

    Open Energy Info (EERE)

    Geothermal Area Wilson Hot Spring Geothermal Area Winnemucca Dry Lake Geothermal Area Energy Generation Facilities within the Walker-Lane Transition Zone Geothermal Region...

  6. Production from multiple zones of a tar sands formation

    DOE Patents [OSTI]

    Karanikas, John Michael; Vinegar, Harold J

    2013-02-26

    A method for treating a tar sands formation includes providing heat to at least part of a hydrocarbon layer in the formation from a plurality of heaters located in the formation. The heat is allowed to transfer from the heaters to at least a portion of the formation. Fluids are produced from the formation through at least one production well that is located in at least two zones in the formation. The first zone has an initial permeability of at least 1 darcy. The second zone has an initial of at most 0.1 darcy. The two zones are separated by a substantially impermeable barrier.

  7. Eastern Energy Zones Mapping Tool | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    The Eastern Interconnection States' Planning Council (EISPC) has released the Energy Zones (EZ) Mapping Tool, a free, web-based interactive tool that will help states and other ...

  8. Variation in sericite composition from fracture zones within...

    Open Energy Info (EERE)

    found in drillhole samples within the geothermal system at Coso Hot Springs. Low-permeability zones of the crystalline basement contain coarse-grained relict muscovite, whereas...

  9. Data Acquisition-Manipulation At Walker-Lane Transitional Zone...

    Open Energy Info (EERE)

    (Coolbaugh, Et Al., 2005 - 2) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Data Acquisition-Manipulation Activity...

  10. Field Mapping At Walker-Lane Transitional Zone Region (Shevenell...

    Open Energy Info (EERE)

    Region (Shevenell, Et Al., 2008) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Field Mapping Activity Date Usefulness...

  11. Geothermometry At Walker-Lane Transitional Zone Region (Shevenell...

    Open Energy Info (EERE)

    (Shevenell & De Rocher, 2005) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Geothermometry Activity Date Usefulness...

  12. Refraction Survey At Walker-Lane Transitional Zone Region (Heimgartner...

    Open Energy Info (EERE)

    Region (Heimgartner, Et Al., 2005) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Refraction Survey Activity Date...

  13. Deep Vadose Zone Applied Field Research Initiative (DVZ-AFRI...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Located on the Hanford Site in Richland, Washington, the Deep Vadose Zone Applied Field Research Initiative (DVZ AFRI) was established to protect water resources by addressing the ...

  14. Modeling-Computer Simulations At Walker-Lane Transitional Zone...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Modeling-Computer Simulations At Walker-Lane Transitional Zone Region (Laney, 2005) Exploration...

  15. Modeling-Computer Simulations At Walker-Lane Transitional Zone...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Modeling-Computer Simulations At Walker-Lane Transitional Zone Region (Pritchett, 2004) Exploration...

  16. Modeling-Computer Simulations At Central Nevada Seismic Zone...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Modeling-Computer Simulations At Central Nevada Seismic Zone Region (Biasi, Et Al., 2009) Exploration...

  17. Modeling-Computer Simulations At Walker-Lane Transitional Zone...

    Open Energy Info (EERE)

    navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Modeling-Computer Simulations At Walker-Lane Transitional Zone Region (Biasi, Et Al., 2009) Exploration...

  18. Geodetic Survey At Central Nevada Seismic Zone Region (Blewitt...

    Open Energy Info (EERE)

    Geodetic Survey At Central Nevada Seismic Zone Region (Blewitt Et Al, 2005) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Geodetic Survey At...

  19. Geothermometry At Central Nevada Seismic Zone Region (Shevenell...

    Open Energy Info (EERE)

    Geothermometry At Central Nevada Seismic Zone Region (Shevenell & De Rocher, 2005) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Geothermometry...

  20. Teleseismic-Seismic Monitoring At Central Nevada Seismic Zone...

    Open Energy Info (EERE)

    Teleseismic-Seismic Monitoring At Central Nevada Seismic Zone Region (Biasi, Et Al., 2008) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity:...

  1. Geodetic Survey At Central Nevada Seismic Zone Region (Laney...

    Open Energy Info (EERE)

    Laney, 2005) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Geodetic Survey At Central Nevada Seismic Zone Region (Laney, 2005) Exploration...

  2. Geodetic Survey At Walker-Lane Transitional Zone Region (Laney...

    Open Energy Info (EERE)

    Laney, 2005) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Geodetic Survey At Walker-Lane Transitional Zone Region (Laney, 2005) Exploration...

  3. Diffusion releases through one and two finite planar zones from...

    Office of Scientific and Technical Information (OSTI)

    Diffusion releases through one and two finite planar zones from a nuclear waste package Citation Details In-Document Search Title: Diffusion releases through one and two finite...

  4. Diffusion releases through one and two finite planar zones from...

    Office of Scientific and Technical Information (OSTI)

    Technical Report: Diffusion releases through one and two finite planar zones from a nuclear waste package Citation Details In-Document Search Title: Diffusion releases through one...

  5. DOE New Madrid Seismic Zone Electric Utility Workshop Summary Report

    Office of Environmental Management (EM)

    DOE New Madrid Seismic Zone Electric Utility Workshop Summary Report August 25, 2010 I In nt tr ro od du uc ct ti io on n The DOE New Madrid Seismic Zone Electric Utilities Workshop, held in Memphis, TN for the electric utilities in the seismic zone was a chance to bring together a diverse set of industry partners to discuss the potential effects of an earthquake in the New Madrid and Wabash Valley seismic zones. The electric sector was well represented by Independent Transmission System

  6. Baoding High Tech Industry Development Zone | Open Energy Information

    Open Energy Info (EERE)

    Name: Baoding High-Tech Industry Development Zone Place: China Product: Government & NGO ( State-owned commercial entity ) References: Baoding High-Tech Industry Development...

  7. Effects of ion-neutral collisions on Alfven waves: The presence of forbidden zone and heavy damping zone

    SciTech Connect (OSTI)

    Weng, C. J.; Lee, L. C.; Kuo, C. L.; Wang, C. B.

    2013-03-15

    Alfven waves are low-frequency transverse waves propagating in a magnetized plasma. We define the Alfven frequency {omega}{sub 0} as {omega}{sub 0}=kV{sub A}cos{theta}, where k is the wave number, V{sub A} is the Alfven speed, and {theta} is the angle between the wave vector and the ambient magnetic field. There are partially ionized plasmas in laboratory, space, and astrophysical plasma systems, such as in the solar chromosphere, interstellar clouds, and the earth ionosphere. The presence of neutral particles may modify the wave frequency and cause damping of Alfven waves. The effects on Alfven waves depend on two parameters: (1) {alpha}=n{sub n}/n{sub i}, the ratio of neutral density (n{sub n}), and ion density (n{sub i}); (2) {beta}={nu}{sub ni}/{omega}{sub 0}, the ratio of neutral collisional frequency by ions {nu}{sub ni} to the Alfven frequency {omega}{sub 0}. Most of the previous studies examined only the limiting case with a relatively large neutral collisional frequency or {beta} Much-Greater-Than 1. In the present paper, the dispersion relation for Alfven waves is solved for all values of {alpha} and {beta}. Approximate solutions in the limit {beta} Much-Greater-Than 1 as well as {beta} Much-Less-Than 1 are obtained. It is found for the first time that there is a 'forbidden zone (FZ)' in the {alpha}-{beta} parameter space, where the real frequency of Alfven waves becomes zero. We also solve the wavenumber k from the dispersion equation for a fixed frequency and find the existence of a 'heavy damping zone (HDZ).' We then examine the presence of FZ and HDZ for Alfven waves in the ionosphere and in the solar chromosphere.

  8. TECHNICAL BASIS FOR EVALUATING SURFACE BARRIERS TO PROTECT GROUNDWATER FROM DEEP VADOSE ZONE CONTAMINATION

    SciTech Connect (OSTI)

    FAYER JM; FREEDMAN VL; WARD AL; CHRONISTER GB

    2010-02-24

    The U.S. DOE and its predecessors released nearly 2 trillion liters (450 billion gallons) of contaminated liquid into the vadose zone at the Hanford Site. Some of the contaminants currently reside in the deeper parts of the vadose zone where they are much less accessible to characterization, monitoring, and typical remediation activities. The DOE Richland Operations Office (DOE-RL) prepared a treatability test plan in 2008 to examine remediation options for addressing contaminants in the deep vadose zone; one of the technologies identified was surface barriers (also known as engineered barriers, covers, and caps). In the typical configuration, the contaminants are located relatively close to the surface, generally within 15 m, and thus they are close to the base of the surface barrier. The proximity of the surface barrier under these conditions yielded few concerns about the effectiveness of the barrier at depth, particularly for cases in which the contaminants were in a lined facility. At Hanford, however, some unlined sites have contaminants located well below depths of 15 m. The issue raised about these sites is the degree of effectiveness of a surface barrier in isolating contaminants in the deep vadose zone. Previous studies by Hanford Site and PNNL researchers suggest that surface barriers have the potential to provide a significant degree of isolation of deep vadose zone contaminants. The studies show that the actual degree of isolation is site-specific and depends on many factors, including recharge rates, barrier size, depth of contaminants, geohydrologic properties ofthe sediments, and the geochemical interactions between the contaminants and the sediments. After the DOE-RL treatability test plan was published, Pacific Northwest National Laboratory was contracted to review the information available to support surface barrier evaluation for the deep vadose zone, identify gaps in the information and outcomes necessary to fill the data gaps, and outline tasks to achieve those outcomes. Full understanding of contaminant behavior in the deep vadose zone is constrained by four key data gaps: limited access; limited data; limited time; and the lack of an accepted predictive capability for determining whether surface barriers can effectively isolate deep vadose zone contaminants. Activities designed to fill these data gaps need to have these outcomes: (1) common evaluation methodology that provides a clear, consistent, and defensible basis for evaluating groundwater impacts caused by placement of a surface barrier above deep vadose zone contamination; (2) deep vadose zone data that characterize the lithology, the spatial distribution of moisture and contaminants, the physical, chemical, and biological process that affect the mobility of each contaminant, and the impacts to the contaminants following placement of a surface barrier; (3) subsurface monitoring to provide subsurface characterization of initial conditions and changes that occur during and following remediation activities; and (4) field observations that span years to decades to validate the evaluation methodology. A set of six proposed tasks was identified to provide information needed to address the above outcomes. The proposed tasks are: (1) Evaluation Methodology - Develop common evaluation methodology that will provide a clear, consistent, and defensible basis for evaluating groundwater impacts caused by placement of a surface barrier above deep vadose zone contamination. (2) Case Studies - Conduct case studies to demonstrate the applicability ofthe common evaluation methodology and provide templates for subsequent use elsewhere. Three sites expected to have conditions that would yield valuable information and experience pertinent to deep vadose zone contamination were chosen to cover a range of conditions. The sites are BC Cribs and Trenches, U Plant Cribs, and the T Farm Interim Cover. (3) Subsurface Monitoring Technologies - Evaluate minimally invasive geophysical approaches for delineating subsurface plumes and monitoring their migration in the deep

  9. Zone Freezing Study for Pyrochemical Process Waste Minimization

    SciTech Connect (OSTI)

    Ammon Williams

    2012-05-01

    Pyroprocessing technology is a non-aqueous separation process for treatment of used nuclear fuel. At the heart of pyroprocessing lies the electrorefiner, which electrochemically dissolves uranium from the used fuel at the anode and deposits it onto a cathode. During this operation, sodium, transuranics, and fission product chlorides accumulate in the electrolyte salt (LiCl-KCl). These contaminates change the characteristics of the salt overtime and as a result, large volumes of contaminated salt are being removed, reprocessed and stored as radioactive waste. To reduce the storage volumes and improve recycling process for cost minimization, a salt purification method called zone freezing has been proposed at Korea Atomic Energy Research Institute (KAERI). Zone freezing is melt crystallization process similar to the vertical Bridgeman method. In this process, the eutectic salt is slowly cooled axially from top to bottom. As solidification occurs, the fission products are rejected from the solid interface and forced into the liquid phase. The resulting product is a grown crystal with the bulk of the fission products near the bottom of the salt ingot, where they can be easily be sectioned and removed. Despite successful feasibility report from KAERI on this process, there were many unexplored parameters to help understanding and improving its operational routines. Thus, this becomes the main motivation of this proposed study. The majority of this work has been focused on the CsCl-LiCl-KCl ternary salt. CeCl3-LiCl-KCl was also investigated to check whether or not this process is feasible for the trivalent species—surrogate for rare-earths and transuranics. For the main part of the work, several parameters were varied, they are: (1) the retort advancement rate—1.8, 3.2, and 5.0 mm/hr, (2) the crucible lid configurations—lid versus no-lid, (3) the amount or size of mixture—50 and 400 g, (4) the composition of CsCl in the salt—1, 3, and 5 wt%, and (5) the temperature differences between the high and low furnace zones—200 and 300 ?C. During each experiment, the temperatures at selected locations around the crucible were measured and recorded to provide temperature profiles. Following each experiment, samples were collected and elemental analysis was done to determine the composition of iii the salt. Several models—non-mixed, well-mixed, Favier, and hybrid—were explored to describe the zone freezing process. For CsCl-LiCl-KCl system, experimental results indicate that through this process up to 90% of the used salt can be recycled, effectively reducing waste volume by a factor of ten. The optimal configuration was found to be a 5.0 mm/hr rate with a lid configuration and a ?T of 200°C. The larger 400 g mixtures had recycle percentages similar to the 50 g mixtures; however, the throughput per time was greater for the 400 g case. As a result, the 400 g case is recommended. For the CeCl3-LiCl-KCl system, the result implies that it is possible to use this process to separate the rare-earth and transuranics chlorides. Different models were applied to only CsCl ternary system. The best fit model was the hybrid model as a result of a solute transport transition from non- mixed to well-mixed throughout the growing process.

  10. Reference Buildings by Climate Zone and Representative City: 7 Duluth, Minnesota

    Broader source: Energy.gov [DOE]

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  11. Directly imaging steeply-dipping fault zones in geothermal fields with multicomponent seismic data

    SciTech Connect (OSTI)

    Chen, Ting; Huang, Lianjie

    2015-07-30

    For characterizing geothermal systems, it is important to have clear images of steeply-dipping fault zones because they may confine the boundaries of geothermal reservoirs and influence hydrothermal flow. Elastic reverse-time migration (ERTM) is the most promising tool for subsurface imaging with multicomponent seismic data. However, conventional ERTM usually generates significant artifacts caused by the cross correlation of undesired wavefields and the polarity reversal of shear waves. In addition, it is difficult for conventional ERTM to directly image steeply-dipping fault zones. We develop a new ERTM imaging method in this paper to reduce these artifacts and directly image steeply-dipping fault zones. In our new ERTM method, forward-propagated source wavefields and backward-propagated receiver wavefields are decomposed into compressional (P) and shear (S) components. Furthermore, each component of these wavefields is separated into left- and right-going, or downgoing and upgoing waves. The cross correlation imaging condition is applied to the separated wavefields along opposite propagation directions. For converted waves (P-to-S or S-to-P), the polarity correction is applied to the separated wavefields based on the analysis of Poynting vectors. Numerical imaging examples of synthetic seismic data demonstrate that our new ERTM method produces high-resolution images of steeply-dipping fault zones.

  12. Directly imaging steeply-dipping fault zones in geothermal fields with multicomponent seismic data

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Chen, Ting; Huang, Lianjie

    2015-07-30

    For characterizing geothermal systems, it is important to have clear images of steeply-dipping fault zones because they may confine the boundaries of geothermal reservoirs and influence hydrothermal flow. Elastic reverse-time migration (ERTM) is the most promising tool for subsurface imaging with multicomponent seismic data. However, conventional ERTM usually generates significant artifacts caused by the cross correlation of undesired wavefields and the polarity reversal of shear waves. In addition, it is difficult for conventional ERTM to directly image steeply-dipping fault zones. We develop a new ERTM imaging method in this paper to reduce these artifacts and directly image steeply-dipping fault zones.more » In our new ERTM method, forward-propagated source wavefields and backward-propagated receiver wavefields are decomposed into compressional (P) and shear (S) components. Furthermore, each component of these wavefields is separated into left- and right-going, or downgoing and upgoing waves. The cross correlation imaging condition is applied to the separated wavefields along opposite propagation directions. For converted waves (P-to-S or S-to-P), the polarity correction is applied to the separated wavefields based on the analysis of Poynting vectors. Numerical imaging examples of synthetic seismic data demonstrate that our new ERTM method produces high-resolution images of steeply-dipping fault zones.« less

  13. Two-zone countercurrent smelter system and process

    DOE Patents [OSTI]

    Cox, J.H.; Fruehan, R.J.; Elliott, J.F.

    1995-01-03

    A process for continuously smelting iron ore by use of coal to yield molten iron or semi-steel is disclosed. The process comprises the steps of establishing a melt covered by slag; inducing the slag and the molten iron to flow countercurrently to one another, toward opposite ends of the smelter; maintaining iron oxide-reducing conditions in that zone of the smelter towards which the slag flows; maintaining carbon-oxidizing conditions in that zone of the smelter towards which the molten iron flows; continuously or semicontinuously tapping the slag from the reducing zone end of the smelter; continuously or semicontinuously tapping the molten iron from the oxidizing zone end of the smelter; and adding to both zones iron ore, coal, oxygen, and flux at addition rates sufficient to keep the molten iron in the reducing zone substantially saturated with carbon, maintain in the slag being tapped an FeO content of about 5 weight percent or less, and maintain in the molten iron being tapped a carbon content of about 0.5 to 5 weight percent. A slag dam preferably is included in the smelter, to impede the backflow of the slag from the reducing zone to the oxidizing zone. A metal bath dam with one or more flow-through portals also is preferably used, submerged below the slag dam, to impede the backflow of the hot metal. 8 figures.

  14. Two-zone countercurrent smelter system and process

    DOE Patents [OSTI]

    Cox, James H. (Toronto, CA); Fruehan, Richard J. (Murrysville, PA); Elliott, deceased, John F. (late of Winchester, MA)

    1995-01-01

    A process for continuously smelting iron ore by use of coal to yield molten iron or semi-steel is disclosed. The process comprises the steps of establishing a melt covered by slag; inducing the slag and the molten iron to flow countercurrently to one another, toward opposite ends of the smelter; maintaining iron oxide-reducing conditions in that zone of the smelter towards which the slag flows; maintaining carbon-oxidizing conditions in that zone of the smelter towards which the molten iron flows; continuously or semicontinuously tapping the slag from the reducing zone end of the smelter; continuously or semicontinuously tapping the molten iron from the oxidizing zone end of the smelter; and adding to both zones iron ore, coal, oxygen, and flux at addition rates sufficient to keep the molten iron in the reducing zone substantially saturated with carbon, maintain in the slag being tapped an FeO content of about 5 weight percent or less, and maintain in the molten iron being tapped a carbon content of about 0.5 to 5 weight percent. A slag dam preferably is included in the smelter, to impede the backflow of the slag from the reducing zone to the oxidizing zone. A metal bath dam with one or more flow-through portals also is preferably used, submerged below the slag dam, to impede the backflow of the hot metal.

  15. Deep Vadose Zone Applied Field Research Initiative (DVZ AFRI) - Overview

    SciTech Connect (OSTI)

    2011-02-01

    The Deep Vadoze Zone Applied Field Research Initiative (DVZ AFRI) was established to protect water resources and to address the challenge of preventing contamination in the deep vadose zone from reaching groundwater. This factsheet provides an overview of the initiative and the approach to integrate basic science and needs-driven applied research activities with cleanup operations.

  16. Significance of Soft Zone Sediments at the SRS

    SciTech Connect (OSTI)

    Aadland, R.K.

    2000-02-03

    The purpose of this report is to provide information on the origin, extent and stability of ''soft zones'' in the carbonate bearing strata at the Savannah River Site (SRS). As part of this study, a comprehensive historical compendium of how soft zones have been addressed during the past 47 years at SRS is reviewed.

  17. Category:County Climate Zones | Open Energy Information

    Open Energy Info (EERE)

    zone information in the United States of America. Contents: Top - 0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Pages in category "County Climate Zones" The following...

  18. Direct measurement and characterization of active photosynthesis zones

    Office of Scientific and Technical Information (OSTI)

    inside biofuel producing and wastewater remediating microalgal biofilms (Journal Article) | SciTech Connect Journal Article: Direct measurement and characterization of active photosynthesis zones inside biofuel producing and wastewater remediating microalgal biofilms Citation Details In-Document Search Title: Direct measurement and characterization of active photosynthesis zones inside biofuel producing and wastewater remediating microalgal biofilms Abstract: Microalgal biofilm based

  19. Combustion Air Zone (CAZ) Best Practices | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Combustion Air Zone (CAZ) Best Practices Combustion Air Zone (CAZ) Best Practices This webinar covered combustion safety testing, several tests, national standards, and implementing combustion safety testing in programs. PDF icon Presentation More Documents & Publications Quality Assurance for Residential Retrofit Programs How to Design and Market Energy Efficiency Programs to Specific Neighborhoods Effective O&M Policy in Public Buildings

  20. Day/Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Day/Time Mon, 12:00 - 6:00 pm Mon, 5:00 pm Mon, 7:00 pm Tues, 7:00 am Tues, 8:00 am Tues, 8:10 am Tues, 8:25 am Tues, 9:25 am Tues, 9:45 am Tues, 11:15 am Tues, 3:45 pm Tues, 4:05 pm Tues, 6:00 pm Wednesday, March 30th Wed, 7:00 am Tues, 7:45 am Tues, 8:00 am Wed, 8:30 am Wed, 12:20 pm Wed, 4:10 pm Wed, 4:30 pm Thursday, March 31st Thurs, 7:00 am Thurs, 11:00 am Thurs, 11:20 am Thurs, 12:30 pm Thurs, 1:00 pm - 4:00 pm P o s t e r s D i s p l a y e d Continental Breakfast / Posters (Salon Del Ray

  1. HYDROGEN GREENHOUSE PLANETS BEYOND THE HABITABLE ZONE

    SciTech Connect (OSTI)

    Pierrehumbert, Raymond; Gaidos, Eric E-mail: gaidos@hawaii.edu

    2011-06-10

    We show that collision-induced absorption allows molecular hydrogen to act as an incondensible greenhouse gas and that bars or tens of bars of primordial H{sub 2}-He mixtures can maintain surface temperatures above the freezing point of water well beyond the 'classical' habitable zone defined for CO{sub 2} greenhouse atmospheres. Using a one-dimensional radiative-convective model, we find that 40 bars of pure H{sub 2} on a three Earth-mass planet can maintain a surface temperature of 280 K out to 1.5 AU from an early-type M dwarf star and 10 AU from a G-type star. Neglecting the effects of clouds and of gaseous absorbers besides H{sub 2}, the flux at the surface would be sufficient for photosynthesis by cyanobacteria (in the G star case) or anoxygenic phototrophs (in the M star case). We argue that primordial atmospheres of one to several hundred bars of H{sub 2}-He are possible and use a model of hydrogen escape to show that such atmospheres are likely to persist further than 1.5 AU from M stars, and 2 AU from G stars, assuming these planets have protecting magnetic fields. We predict that the microlensing planet OGLE-05-390Lb could have retained an H{sub 2}-He atmosphere and be habitable at {approx}2.6 AU from its host M star.

  2. High gain photoconductive semiconductor switch having tailored doping profile zones

    DOE Patents [OSTI]

    Baca, Albert G. (Albuquerque, NM); Loubriel, Guillermo M. (Albuquerque, NM); Mar, Alan (Albuquerque, NM); Zutavern, Fred J (Albuquerque, NM); Hjalmarson, Harold P. (Albuquerque, NM); Allerman, Andrew A. (Albuquerque, NM); Zipperian, Thomas E. (Edgewood, NM); O'Malley, Martin W. (Edgewood, NM); Helgeson, Wesley D. (Albuquerque, NM); Denison, Gary J. (Sandia Park, NM); Brown, Darwin J. (Albuquerque, NM); Sullivan, Charles T. (Albuquerque, NM); Hou, Hong Q. (Albuquerque, NM)

    2001-01-01

    A photoconductive semiconductor switch with tailored doping profile zones beneath and extending laterally from the electrical contacts to the device. The zones are of sufficient depth and lateral extent to isolate the contacts from damage caused by the high current filaments that are created in the device when it is turned on. The zones may be formed by etching depressions into the substrate, then conducting epitaxial regrowth in the depressions with material of the desired doping profile. They may be formed by surface epitaxy. They may also be formed by deep diffusion processes. The zones act to reduce the energy density at the contacts by suppressing collective impact ionization and formation of filaments near the contact and by reducing current intensity at the contact through enhanced current spreading within the zones.

  3. Deficiencies in Vadose Zone Understanding at the INEEL

    SciTech Connect (OSTI)

    Wood, Thomas Ronald; Bates, Dona Louise; Bishop, Carolyn Wagoner; Heard, Robert Eugene; Hubbell, Joel Michael; Hull, Laurence Charles; Lehman, Richard Michael; Magnuson, Swen O; Mattson, Earl Douglas; Mccarthy, James Michael; Porro, Indrek; Ritter, Paul David; Roddy, Michael Scott; Singler, Robert Edward; Smith, Richard Paul

    2000-08-01

    Subsurface contamination in the vadose zone, that portion of the subsurface pathway between land surface and an underlying aquifer, poses environmental problems at the Idaho National Engineering and Environmental Laboratory (INEEL) in eastern Idaho and across the U.S. Department of Energy complex. Assessing potential adverse impacts from these contaminated sites requires an understanding of the mechanisms controlling contaminant transport. Currently, vadose zone experts at the INEEL cannot with confidence predict the movement of water and contaminants in the complex, heterogeneous, fractured subsurface at the INEEL, especially within the vadose zone. In the draft version (Revision 1) of the Vadose Zone Deficiencies document, deficiencies in scientific understanding of flow and transport processes in the vadose zone at the INEEL were identified and grouped into 13 categories and recommendations were provided to address each of the deficiencies. The draft document provided the basis for an INEEL Vadose Zone Workshop that was conducted October 20 and 21, 1999, in Idaho Falls, Idaho. The workshop was conducted to group and rank the previously identified deficiencies and for the subsequent development of science plans to address the deficiencies that limit reliable predictions of water and contaminant movement in the subsurface. The workshop participants, comprising INEEL and scientists and project managers and non-INEEL scientists knowledgeable about the vadose zone, developed science- and technology-based recommendations derived through a series of technical sessions at the workshop. In this document, the final version of the Vadose Zone Deficiencies document, the draft document has been incorporated, largely intact, as well as the results from the workshop. The workshop participants grouped the deficiencies in vadose zone understanding at the INEEL into seven categories. These seven categories will be the focus areas of five science plans that are being developed to address the deficiencies. This document lays the foundation for the INEEL Site-wide vadose zone roadmap.

  4. A new estimate of the chondrule cooling rate deduced from an analysis of compositional zoning of relict olivine

    SciTech Connect (OSTI)

    Miura, H.; Yamamoto, T.

    2014-03-01

    Compositional zoning in chondrule phenocrysts records the crystallization environments in the early solar nebula. We modeled the growth of olivine phenocrysts from a silicate melt and proposed a new fractional crystallization model that provides a relation between the zoning profile and the cooling rate. In our model, we took elemental partitioning at a growing solid-liquid interface and time-dependent solute diffusion in the liquid into consideration. We assumed a local equilibrium condition, namely, that the compositions at the interface are equal to the equilibrium ones at a given temperature. We carried out numerical simulations of the fractional crystallization in one-dimensional planar geometry. The simulations revealed that under a constant cooling rate the growth velocity increases exponentially with time and a linear zoning profile forms in the solid as a result. We derived analytic formulae of the zoning profile, which reproduced the numerical results for wide ranges of crystallization conditions. The formulae provide a useful tool to estimate the cooling rate from the compositional zoning. Applying the formulae to low-FeO relict olivine grains in type II porphyritic chondrules observed by Wasson and Rubin, we estimate the cooling rate to be ?200-2000 K s{sup –1}, which is greater than that expected from furnace-based experiments by orders of magnitude. Appropriate solar nebula environments for such rapid cooling conditions are discussed.

  5. Western Renewable Energy Zones, Phase 1: QRA Identification Technical Report

    SciTech Connect (OSTI)

    Pletka, R.; Finn, J.

    2009-10-01

    This report describes the Western Renewable Energy Zones (WREZ) Initiative Phase 1 Qualified Resource Area identification process, including the identification and economic analysis of Qualified Resource Areas (QRAs) and 'non-REZ' resources. These data and analyses will assist the Western US in its renewable energy transmission planning goals. The economic analysis in this report produced the input data for the WREZ Generation and Transmission model, which is a screening-level model to determine the optimal routing for and cost of delivering renewable energy from QRAs to load centers throughout the Western Interconnection. In June 2009, the Western Governors' Association accepted the Western Governors' Association WREZ Phase 1 Report in which the QRAs were mapped and the entire WREZ Phase 1 process was explained in general. That same month the Lawrence Berkeley National Laboratory released the WREZ Generation and Transmission Model (GTM), which was also developed by Black & Veatch. This report details the assumptions and methodologies that were used to produce the maps and resource analyses in the WGA report as well as the economic data used by the WREZ GTM. This report also provides the results of the non-REZ resource analysis for the first time in the WREZ initiative.

  6. Zoning for earth sheltered buildings. A guide for Minnesota communities

    SciTech Connect (OSTI)

    Not Available

    1983-08-01

    Background information on earth sheltered buildings and the zoning issues related to this construction techniques is provided. Ways to develop goals and policies on earth sheltering and integrate them into existing planning documents are outlined. Ways to eliminate prohibitions and barriers to earth-sheltered buildings from zoning language are explained. Subdivision and planned unit development (PUD) regulations designed to facilitate and encourage new developments of earth sheltered homes are considered. Model language on planning, zoning, and subdivisions and planned unit developments and a summary of the various recommendations made throughout the guidebook are included. (MHR)

  7. Electrically heated particulate filter with zoned exhaust flow control

    DOE Patents [OSTI]

    Gonze, Eugene V [Pinckney, MI

    2012-06-26

    A system includes a particulate matter (PM) filter that includes X zones. An electrical heater includes Y heater segments that are associated with respective ones of the X zones. The electrical heater is arranged upstream from and proximate with the PM filter. A valve assembly includes Z sections that are associated with respective ones of the X zones. A control module adjusts flow through each of the Z sections during regeneration of the PM filter via control of the valve assembly. X, Y and Z are integers.

  8. Table HC9.9 Home Appliances Characteristics by Climate Zone, 2005

    Gasoline and Diesel Fuel Update (EIA)

    9 Home Appliances Characteristics by Climate Zone, 2005 Million U.S. Housing Units Total U.S............................................................ 111.1 10.9 26.1 27.3 24.0 22.8 Cooking Appliances Conventional Ovens Use an Oven............................................... 109.6 10.9 25.7 27.1 23.4 22.4 1.............................................................. 103.3 10.2 24.3 25.3 22.2 21.3 2 or More................................................. 6.2 0.6 1.5 1.8 1.2 1.1 Do Not Use

  9. An Analysis of Dual Zone Loading for Shipping Spent Nuclear Fuel

    SciTech Connect (OSTI)

    Allen, William Christopher; Yim, Man-Sung

    2007-07-01

    The bumps current fuel assembly designs can achieve exceeds the fuel assembly burnups the current fleet of shipping casks can ship. One method of handling this situation which has been proposed is regionalized loading. This concept involves administratively separating the fuel basket of a shipping cask into two or more regions and loading fuel with different burnup, cooling times and enrichments into these regions. To evaluate how regionalized loading patterns might affect shipping spent nuclear fuel in comparison to uniform loading, a test case study was performed using fuel assemblies discharged from an actual nuclear plant and a shipping cask licensed by the NRC. Using the same fuel assemblies and shipping cask, results were obtained assuming a uniform loading pattern and compared to the results obtained assuming a dual zone loading pattern. Source terms for the analysis were generated using SAS2 and the dose levels were calculated using MCNPS. The analysis showed that the dual zone loading reduced the amount of time required to ship the given quantity of fuel by roughly thirty percent compared to the uniform loading. The average dose rate to the transportation workers and the public due to the implementation of dual zone loading increased. Implications of these increases are discussed. (authors)

  10. Saturated Zone In-Situ Testing

    SciTech Connect (OSTI)

    P. W. Reimus; M. J. Umari

    2003-12-23

    The purpose of this scientific analysis is to document the results and interpretations of field experiments that have been conducted to test and validate conceptual flow and radionuclide transport models in the saturated zone (SZ) near Yucca Mountain. The test interpretations provide estimates of flow and transport parameters that are used in the development of parameter distributions for Total System Performance Assessment (TSPA) calculations. These parameter distributions are documented in the revisions to the SZ flow model report (BSC 2003 [ 162649]), the SZ transport model report (BSC 2003 [ 162419]), the SZ colloid transport report (BSC 2003 [162729]), and the SZ transport model abstraction report (BSC 2003 [1648701]). Specifically, this scientific analysis report provides the following information that contributes to the assessment of the capability of the SZ to serve as a barrier for waste isolation for the Yucca Mountain repository system: (1) The bases for selection of conceptual flow and transport models in the saturated volcanics and the saturated alluvium located near Yucca Mountain. (2) Results and interpretations of hydraulic and tracer tests conducted in saturated fractured volcanics at the C-wells complex near Yucca Mountain. The test interpretations include estimates of hydraulic conductivities, anisotropy in hydraulic conductivity, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, matrix diffusion coefficients, fracture apertures, and colloid transport parameters. (3) Results and interpretations of hydraulic and tracer tests conducted in saturated alluvium at the Alluvium Testing Complex (ATC), which is located at the southwestern corner of the Nevada Test Site (NTS). The test interpretations include estimates of hydraulic conductivities, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, and colloid transport parameters. (4) Comparisons of sorption parameter estimates for a reactive solute tracer (lithium ion) derived from both the C-wells field tracer tests and laboratory tests using C-wells core samples. (5) Sorption parameter estimates for lithium ion derived from laboratory tests using alluvium samples from NC-EWDP-19D1 (one of the wells at the ATC) so that a comparison of laboratory- and field-derived sorption parameters can be made in saturated alluvium if cross-hole tracer tests are conducted at the ATC.

  11. app_c7

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 Description of Input and Final Waste Streams C.7-iii DOE/EIS-0287 Idaho HLW & FD EIS TABLE OF CONTENTS Section Page Appendix C.7 Description of Input and Final Waste Streams C.7-1 LIST OF TABLES Table Page C.7-1 Waste processing alternative inputs. C.7-1 C.7-2 Bin set total chemical inventory (fission and activation species decayed to 2016). C.7-2 C.7-3 Bin set total inventory of radionuclides (decayed to 2016). C.7-3 C.7-4 Calculated radionuclides activities for SBW (curies per liter)

  12. The Use of Radar Methods to Determine Moisture Content in the Vadose Zone

    SciTech Connect (OSTI)

    Rosemary Knight

    2003-12-28

    Water content is a critical parameter affecting both liquid-phase and vapor-phase contaminant transport in the vadose zone. This means that accurate estimate of in situ water content must be obtained in order to design for the appropriate handling or remediation of a contaminated region of the vadose zone. Traditional methods of sampling the subsurface by drilling and/or direct sampling are very time consuming, limited in terms of spatial coverage, and have the associated risk of contacting and increasing the size of the contaminated area. One solution is to use geophysical methods which can provide a high-resolution, non-invasive means of sampling or imagin the subsurface.

  13. Barrow County, Georgia ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Barrow County, Georgia ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Barrow County, Georgia ASHRAE Standard ASHRAE 169-2006 Climate Zone Number...

  14. Ben Hill County, Georgia ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Ben Hill County, Georgia ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Ben Hill County, Georgia ASHRAE Standard ASHRAE 169-2006 Climate Zone...

  15. Bacon County, Georgia ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Bacon County, Georgia ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Bacon County, Georgia ASHRAE Standard ASHRAE 169-2006 Climate Zone Number...

  16. Baca County, Colorado ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Baca County, Colorado ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Baca County, Colorado ASHRAE Standard ASHRAE 169-2006 Climate Zone Number...

  17. Apache County, Arizona ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Apache County, Arizona ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Apache County, Arizona ASHRAE Standard ASHRAE 169-2006 Climate Zone Number...

  18. Adams County, Indiana ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Adams County, Indiana ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Adams County, Indiana ASHRAE Standard ASHRAE 169-2006 Climate Zone Number...

  19. Adams County, Idaho ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Adams County, Idaho ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Adams County, Idaho ASHRAE Standard ASHRAE 169-2006 Climate Zone Number...

  20. Adams County, Illinois ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Adams County, Illinois ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Adams County, Illinois ASHRAE Standard ASHRAE 169-2006 Climate Zone Number...

  1. Adams County, Nebraska ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Adams County, Nebraska ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Adams County, Nebraska ASHRAE Standard ASHRAE 169-2006 Climate Zone Number...

  2. Adams County, Ohio ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Adams County, Ohio ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Adams County, Ohio ASHRAE Standard ASHRAE 169-2006 Climate Zone Number Climate...

  3. Bates County, Missouri ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Bates County, Missouri ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Bates County, Missouri ASHRAE Standard ASHRAE 169-2006 Climate Zone Number...

  4. Certification of Consistency with Washington's Coastal Zone Management...

    Open Energy Info (EERE)

    Zone Management Program for Federally Licensed or Permitted ActivitiesLegal Published NA Year Signed or Took Effect The date "NA" was not understood.The date "NA" was not...

  5. Certification of Consistency with Washington's Coastal Zone Management...

    Open Energy Info (EERE)

    Coastal Zone Management Program for Federally Funded ActivitiesLegal Published NA Year Signed or Took Effect The date "NA" was not understood.The date "NA" was not...

  6. Carbon Dioxide Emissions From Vegetation-Kill Zones Around The...

    Open Energy Info (EERE)

    Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Carbon Dioxide Emissions From Vegetation-Kill Zones Around The Resurgent Dome Of Long Valley...

  7. Fluid Stratigraphy and Permeable Zones of the Coso Geothermal...

    Open Energy Info (EERE)

    zones can be targeted in the future Authors Dilley, L. M.; Norman, D.I.; Moore, J.; McCulloch and J. Published Geothermal Resource Council Transactions 2006, 112006 DOI...

  8. Solar-Powered, School-Zone Safety | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Solar-powered flashing LED beacons are making Bethany, OK, schoolchildren safer by reminding drivers to abide by posted school-zone speeds. | Photo Courtesy of Bethany, OK | Solar-...

  9. Montana Guide to the Streamside Management Zone Law & Rules Webpage...

    Open Energy Info (EERE)

    Guide to the Streamside Management Zone Law & Rules Webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Montana Guide to the Streamside Management...

  10. Varying heating in dawsonite zones in hydrocarbon containing formations

    DOE Patents [OSTI]

    Vinegar, Harold J. (Bellaire, TX); Xie, Xueying (Houston, TX); Miller, David Scott (Katy, TX)

    2009-07-07

    A method for treating an oil shale formation comprising dawsonite includes assessing a dawsonite composition of one or more zones in the formation. Heat from one or more heaters is provided to the formation such that different amounts of heat are provided to zones with different dawsonite compositions. The provided heat is allowed to transfer from the heaters to the formation. Fluids are produced from the formation.

  11. Characterization of microstructural strengthening in the heat-affected zone

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of a blast-resistant naval steel | Energy Frontier Research Centers microstructural strengthening in the heat-affected zone of a blast-resistant naval steel Home Author: X. Yu, J. Caron, S. S. Babu, J. C. Lippold, D. Isheim, D. N. Seidman Year: 2010 Abstract: The influence of simulated heat-affected zone thermal cycles on the microstructural evolution in a blast-resistant naval steel was investigated by dilatometry, microhardness testing, optical microscopy, electron backscatter diffraction

  12. Uncertainty quantification for evaluating the impacts of fracture zone on

    Office of Scientific and Technical Information (OSTI)

    pressure build-up and ground surface uplift during geological CO₂ sequestration (Journal Article) | SciTech Connect Uncertainty quantification for evaluating the impacts of fracture zone on pressure build-up and ground surface uplift during geological CO₂ sequestration Citation Details In-Document Search Title: Uncertainty quantification for evaluating the impacts of fracture zone on pressure build-up and ground surface uplift during geological CO₂ sequestration A series of numerical

  13. Review of Literature on Terminal Box Control, Occupancy Sensing Technology and Multi-zone Demand Control Ventilation (DCV)

    SciTech Connect (OSTI)

    Liu, Guopeng; Dasu, Aravind R.; Zhang, Jian

    2012-03-01

    This report presents an overall review of the standard requirement, the terminal box control, occupancy sensing technology and DCV. There is system-specific guidance for single-zone systems, but DCV application guidance for multi-zone variable air volume (VAV) systems is not available. No real-world implementation case studies have been found using the CO2-based DCV. The review results also show that the constant minimum air flow set point causes excessive fan power consumption and potential simultaneous heating and cooling. Occupancy-based control (OBC) is needed for the terminal box in order to achieve deep energy savings. Key to OBC is a technology for sensing the actual occupancy of the zone served in real time. Several technologies show promise, but none currently fully meets the need with adequate accuracy and sufficiently low cost.

  14. Aroostook County, Maine ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Help Apps Datasets Community Login | Sign Up Search Page Edit History Aroostook County, Maine ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place...

  15. InSAR At Walker-Lane Transitional Zone Region (Laney, 2005) ...

    Open Energy Info (EERE)

    Zone Region (Laney, 2005) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique InSAR Activity Date Usefulness useful...

  16. A Micro-Variable Circular Orifice (MVCO) Fuel Injector for Zoned...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    A Micro-Variable Circular Orifice (MVCO) Fuel Injector for Zoned Low Temperature Combustion A Micro-Variable Circular Orifice (MVCO) Fuel Injector for Zoned Low Temperature ...

  17. Fiscal Year 2007 Phased Construction Completion Report for the Zone 2 Soils, Slabs, and Subsurface Structures at East Tennessee Technology Park, Oak Ridge, Tennessee

    SciTech Connect (OSTI)

    RSI

    2008-03-01

    The purpose of this Phased Construction Completion Report (PCCR) is to present the fiscal year (FY) 2007 results of characterization activities and recommended remedial actions (RAs) for 11 exposure units (EUs) in Zone 2 (Z2-01, Z2-03, Z2-08, Z2-23, Z2-24, Z2-28, Z2-34, Z2-37, Z2-41, Z2-43, and Z2-44) at the East Tennessee Technology Park (ETTP), which is located in the northwest corner of the U.S. Department of Energy (DOE) Oak Ridge Reservation in Oak Ridge, Tennessee (Fig. 1). ETTP encompasses a total land area of approximately 5000 acres that has been subdivided into three zones--Zone 1 ({approx}1400 acres), Zone 2 ({approx}800 acres), and the Boundary Area ({approx}2800 acres). Zone 2, which encompasses the highly industrialized portion of ETTP shown in Fig. 1, consists of all formerly secured areas of the facility, including the large processing buildings and direct support facilities; experimental laboratories and chemical and materials handling facilities; materials storage and waste disposal facilities; secure document records libraries; and shipping and receiving warehouses. The Zone 2 Record of Decision for Soil, Buried Waste, and Subsurface Structure Actions in Zone 2, East Tennessee Technology Park, Oak Ridge, Tennessee (DOE 2005) (Zone 2 ROD) specifies the future end use for Zone 2 acreage as uncontrolled industrial for the upper 10 ft of soils. Characterization activities in these areas were conducted in compliance with the Zone 2 ROD and the Dynamic Verification Strategy (DVS) and data quality objectives (DQOs) presented in the Remedial Design Report/Remedial Action Work Plan for Zone 2 Soils, Slabs, and Subsurface Structures, East Tennessee Technology Park, Oak Ridge, Tennessee (DOE 2007) (Zone 2 RDR/RAWP). The purpose of this PCCR is to address the following: (1) Document DVS characterization results for the accessible EUs in FY 2007; (2) Describe and document the risk evaluation for each EU, and determine if the EU met the Zone 2 ROD requirements for unrestricted industrial use to 10 ft bgs; (3) Identify additional areas not defined in the Zone 2 ROD that require remediation based on the DVS evaluation results; and (4) Describe the RAs performed in Zone 2. The Zone 2 ROD divided the Zone 2 area into 7 geographic areas and 44 EUs. To facilitate the DQOs of the DVS process, the Zone 2 RDR/RAWP regrouped the 44 EUs into 12 DQO scoping EU groups. These groups facilitated the DQO process by placing similar facilities and their support facilities together and allowed identification of data gaps. The EU groups were no longer pertinent after DQO planning was completed, and characterization was conducted as areas became accessible. As the opportunity to complete characterization became available, the planned DVS program was executed and completed in FY 2007 for the 11 EUs addressed in this document. The main body of this report describes both the DVS process and scope of work performed and the RAs completed. The scope and approach for performing DVS activities performed in FY 2007 that lead to action/no further action decisions are presented in Sects. 2 through 4. RAs performed in FY 2007 are presented in Sects. 5 through 10. Future land use is described in Sect. 11, and the status of all Zone 2 EUs as of this PCCR is presented in Sect. 12.

  18. EnergyPlus Version 7

    Energy Science and Technology Software Center (OSTI)

    2011-11-01

    EnergyPlus is a whole building energy simulation program that engineers, architects and researchers use to model energy and water use in buildings. Modeling the performance of a building with EnergyPlus enables building professionals to optimize the building design to use less energy and water. Each version of EnergyPlus is tested extensively before release. EnergyPlus models heating, cooling, lighting, ventilation, other energy flows, and water use. EnergyPlus includes many innovation simulation capabilities: time-steps less than anmore » hour, modular systems and plant integrated with heat balance-based zone simulation, multizone air flow, thermal comfort, water use, natural ventilation, and photovoltaic systems. EnergyPlus runs on the Windows, Macintosh, and Linux platforms. Free add-ons and other third party software products are available for use with EnergyPlus.« less

  19. Deep Vadose Zone-Applied Field Research Initiative Fiscal Year 2011 Annual Report

    SciTech Connect (OSTI)

    Wellman, Dawn M.; Johnson, Timothy C.; Smith, Ronald M.; Truex, Michael J.; Matthews, Hope E.

    2011-10-01

    This annual report describes the background of the Deep Vadose Zone-Applied Field Research Initiative, and some of the programmatic approaches and transformational technologies in groundwater and deep vadose zone remediation developed during fiscal year 2011. The Department of Energy (DOE) Office of Technology Innovation and Development's (OTID) mission is to transform science into viable solutions for environmental cleanup. In 2010, OTID developed the Impact Plan, Science and Technology to Reduce the Life Cycle Cost of Closure to outline the benefits of research and development of the lifecycle cost of cleanup across the DOE complex. This plan outlines OTID's ability to reduce by $50 billion, the $200 billion life-cycle cost in waste processing, groundwater and soil, nuclear materials, and deactivation and decommissioning. The projected life-cycle costs and return on investment are based on actual savings realized from technology innovation, development, and insertion into remedial strategies and schedules at the Fernald, Mound, and Ashtabula sites. To achieve our goals, OTID developed Applied Field Research Initiatives to facilitate and accelerate collaborative development and implementation of new tools and approaches that reduce risk, cost and time for site closure. The primary mission of the Deep Vadose Zone-Applied Field Research Initiative (DVZ-AFRI) is to protect our nation's water resources, keeping them clean and safe for future generations. The DVZ-AFRI was established for the DOE to develop effective, science-based solutions for remediating, characterizing, monitoring, and predicting the behavior and fate of deep vadose zone contamination. Subsurface contaminants include radionuclides, metals, organics, and liquid waste that originated from various sources, including legacy waste from the nation's nuclear weapons complexes. The DVZ-AFRI project team is translating strategy into action by working to solve these complex challenges in a collaborative environment that leverages technology and scientific expertise from DOE, Pacific Northwest National Laboratory, CH2M HILL Plateau Remediation Company, and the broad scientific research community. As project manager for the DVZ-AFRI, I have had the privilege this past year to team with creative, talented members of the scientific community nationwide to develop effective long-term solutions to address deep vadose zone contamination. This report highlights how the DVZ-AFRI project team is delivering results by achieving significant programmatic accomplishments, and developing and field-testing transformational technologies to address the nation's most pressing groundwater and vadose zone contamination problems.

  20. Attachment C7

    Office of Environmental Management (EM)

    C7 TRU WASTE CONFIRMATION Waste Isolation Pilot Plant Hazardous Waste Permit March 13, 2013 (This page intentionally blank) Waste Isolation Pilot Plant Hazardous Waste Permit March 13, 2013 PERMIT ATTACHMENT C7 Page C7-i ATTACHMENT C7 TRU WASTE CONFIRMATION TABLE OF CONTENTS Introduction ................................................................................................................................. 1 C7-1 Permittee Confirmation of TRU Mixed Waste

  1. Genepool Time Heatmaps

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Genepool Time Heatmaps Heatmap of Time and Slots Requested vs Time Waited (in hours) | Queue: All | Last 7 Days Time Requested Slots <1h 1-2h 2-6h 6-12h 12-24h 24-36h 36-48h 48h-1wk >1wk Job Count Longest Wait 1 23.0 (233) 0.37 (1819) 27.54 (49888) 5.85 (124593) 1.23 (39835) 0.34 (732) 0 0.4 (224) 0.02 (1) 217325 538.96 2 0 0.01 (19) 2.54 (78) 0.2 (140) 0.99 (2683) 0 0 0 0 2920 9.1 4 0.08 (1) 0 2.82 (141) 0.36 (143) 1.07 (12) 0.06 (5) 0.01 (5) 0.06 (1) 1.3 (5) 313 20.48 6 0.01 (2) 0 0.09

  2. Effects of Porous Medium Heterogeneity on Vadose Zone Desiccation: Intermediate-scale Laboratory Experiments and Simulations

    SciTech Connect (OSTI)

    Oostrom, Martinus; Freedman, Vicky L.; Wietsma, Thomas W.; Dane, Jacob H.; Truex, Michael J.

    2012-11-01

    Soil desiccation (drying), involving water evaporation induced by dry gas injection, is a potentially robust vadose zone remediation process to limit contaminant transport through the vadose zone. A series of four intermediate-scale flow cell experiments was conducted in homogeneous and simple layered heterogeneous porous medium systems to investigate the effects of heterogeneity on desiccation of unsaturated porous media. The permeability ratios of porous medium layers ranged from about five to almost two orders of magnitude. The insulated flow cell was equipped with twenty humidity and temperature sensors and a dual-energy gamma system was used to determine water saturations at various times. The multiphase code STOMP was used to simulate the desiccation process. Results show that injected dry gas flowed predominantly in the higher permeability layer and delayed water removal from the lower permeability material. For the configurations tested, water vapor diffusion from the lower to the higher permeability zone was considerable over the duration of the experiments, resulting in much larger relative humidity values of the outgoing air than based on permeability ratios alone. Acceptable numerical matches with the experimental data were obtained when an extension of the saturation-capillary pressure relation below the residual water saturation was used. The agreements between numerical and experimental results suggest that the correct physics are implemented in the simulator and that the thermal and hydraulic properties of the porous media, flow cell wall and insulation materials were properly represented.

  3. Hydrogeology of the unsaturated zone, North Ramp area of the Exploratory Studies Facility, Yucca Mountain, Nevada

    SciTech Connect (OSTI)

    Rousseau, J.P.; Kwicklis, E.M.; Gillies, D.C.

    1999-03-01

    Yucca Mountain, in southern Nevada, is being investigated by the US Department of Energy as a potential site for a repository for high-level radioactive waste. This report documents the results of surface-based geologic, pneumatic, hydrologic, and geochemical studies conducted during 1992 to 1996 by the US Geological Survey in the vicinity of the North Ramp of the Exploratory Studies Facility (ESF) that are pertinent to understanding multiphase fluid flow within the deep unsaturated zone. Detailed stratigraphic and structural characteristics of the study area provided the hydrogeologic framework for these investigations. Shallow infiltration is not discussed in detail in this report because the focus in on three major aspects of the deep unsaturated-zone system: geologic framework, the gaseous-phase system, and the aqueous-phase system. However, because the relation between shallow infiltration and deep percolation is important to an overall understanding of the unsaturated-zone flow system, a summary of infiltration studies conducted to date at Yucca Mountain is provided in the section titled Shallow Infiltration. This report describes results of several Site Characterization Plan studies that were ongoing at the time excavation of the ESF North Ramp began and that continued as excavation proceeded.

  4. Visualizing Life Zone Boundary Sensitivities Across Climate Models and Temporal Spans

    SciTech Connect (OSTI)

    Sisneros, Roberto R; Huang, Jian; Ostrouchov, George; Hoffman, Forrest M

    2011-01-01

    Life zones are a convenient and quantifiable method for delineating areas with similar plant and animal communities based on bioclimatic conditions. Such ecoregionalization techniques have proved useful for defining habitats and for studying how these habitats may shift due to environmental change. The ecological impacts of climate change are of particular interest. Here we show that visualizations of the geographic projection of life zones may be applied to the investigation of potential ecological impacts of climate change using the results of global climate model simulations. Using a multi-factor classification scheme, we show how life zones change over time based on quantitative model results into the next century. Using two straightforward metrics, we identify regions of high sensitivity to climate changes from two global climate simulations under two different greenhouse gas emissions scenarios. Finally, we identify how preferred human habitats may shift under these scenarios. We apply visualization methods developed for the purpose of displaying multivariate relationships within data, especially for situations that involve a large number of concurrent relationships. Our method is based on the concept of multivariate classification, and is implemented directly in VisIt, a production quality visualization package.

  5. Controlled short residence time coal liquefaction process

    DOE Patents [OSTI]

    Anderson, Raymond P. (Overland Park, KS); Schmalzer, David K. (Englewood, CO); Wright, Charles H. (Overland Park, KS)

    1982-05-04

    Normally solid dissolved coal product and a distillate liquid product are produced by continuously passing a feed slurry comprising raw feed coal and a recycle solvent oil and/or slurry together with hydrogen to a preheating-reaction zone (26, alone, or 26 together with 42), the hydrogen pressure in the preheating-reaction zone being at least 1500 psig (105 kg/cm.sup.2), reacting the slurry in the preheating-reaction zone (26, or 26 with 42) at a temperature in the range of between about 455.degree. and about 500.degree. C. to dissolve the coal to form normally liquid coal and normally solid dissolved coal. A total slurry residence time is maintained in the reaction zone ranging from a finite value from about 0 to about 0.2 hour, and reaction effluent is continuously and directly contacted with a quenching fluid (40, 68) to substantially immediately reduce the temperature of the reaction effluent to below 425.degree. C. to substantially inhibit polymerization so that the yield of insoluble organic matter comprises less than 9 weight percent of said feed coal on a moisture-free basis. The reaction is performed under conditions of temperature, hydrogen pressure and residence time such that the quantity of distillate liquid boiling within the range C.sub.5 -455.degree. C. is an amount at least equal to that obtainable by performing the process under the same conditions except for a longer total slurry residence time, e.g., 0.3 hour. Solvent boiling range liquid is separated from the reaction effluent and recycled as process solvent.

  6. 7Li Cross Section

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7Li(, '): emission yield 1.0 - 3.4 1 01182012 2011YA02 7Li(, ): elastic scattering differential 1.0 - 4.5 cm 170 07192011 7Li(, p): differential...

  7. Potential for Microbial Stimulation in Deep Vadose Zone Sediments by Gas-Phase Nutrients

    SciTech Connect (OSTI)

    Li, S.W.; Plymale, A. E.; Brockman, F.J.

    2006-04-05

    Viable microbial populations are low, typically 10{sup 4} cells per gram, in deep vadose zones in arid climates. There is evidence that microbial distribution in these environments is patchy. In addition, infiltration or injection of nutrient-laden water has the potential to spread and drive contaminants downward to the saturated zone. For these reasons, there are uncertainties regarding the feasibility of bioremediation of recalcitrant contaminants in deep vadose zones. The objectives of this study were to investigate the occurrence of denitrifying activity and gaseous carbon-utilizing activity in arid-climate deep vadose zone sediments contaminated with, and/or affected by past exposure to, carbon tetrachloride (CT). These metabolisms are known to degrade CT and/or its breakdown product chloroform under anoxic conditions. A second objective was to determine if CT would be degraded in these sediments under unsaturated, bulk-phase aerobic incubation conditions. Both denitrifier population (determined by MPN) and microbial heterotrophic activity (measured by mineralization of 14-C labeled glucose and acetate) were relatively low and the sediments with greater in situ moisture (10-21% versus 2-7%) tended to have higher activities. When sediments were amended with gaseous nutrients (nitrous oxide and triethyl/tributyl phosphate) and gaseous C sources (a mixture of methane, ethane, propylene, propane, and butane) and incubated for 6 months, approximately 50% of the samples showed removal of one or more gaseous C sources, with butane most commonly used (44% of samples), followed by propylene (42%), propane (31%), ethane (22%), and methane (4%). Gaseous N and gaseous P did not stimulate removal of gaseous C substrates compared to no addition of N and P. CT and gaseous C sources were spiked into the sediments that removed gaseous C sources to determine if hydrocarbon-degraders have the potential to degrade CT under unsaturated conditions. In summary, gaseous C sources--particularly butane and propylene--have promise for increasing the numbers and activity of indigenous microbial populations in arid-climate deep vadose zone sediments.

  8. Preliminary result of teleseismic double-difference relocation of earthquakes in the Molucca collision zone with a 3D velocity model

    SciTech Connect (OSTI)

    Shiddiqi, Hasbi Ash E-mail: h.a.shiddiqi@gmail.com; Widiyantoro, Sri; Nugraha, Andri Dian; Ramdhan, Mohamad; Wandono,; Sutiyono,; Handayani, Titi; Nugroho, Hendro

    2015-04-24

    We have relocated hypocenters of earthquakes occurring in the Molucca collision zone and surrounding region taken from the BMKG catalog using teleseismic double-difference relocation algorithm (teletomoDD). We used P-wave arrival times of local, regional, and teleseismic events recorded at 304 recording stations. Over 7,000 earthquakes were recorded by the BMKG seismographicnetworkin the study region from April, 2009 toJune, 2014. We used a 3D regional-global nested velocity modelresulting fromprevious global tomographystudy. In this study, the3D seismic velocity model was appliedto theIndonesian region, whilethe1D seismicvelocity model (ak135)wasused for regions outside of Indonesia. Our relocation results show a better improvement in travel-time RMS residuals comparedto those of the BMKG catalog.Ourresultsalso show that relocation shifts were dominated intheeast-west direction, whichmaybeinfluenced by theexistingvelocity anomaly related to the reversed V-shaped slabbeneaththestudy region. Our eventrelocation results refine the geometry of slabs beneath the Halmahera and Sangihe arcs.

  9. Vadose Zone Transport Field Study: FY 2002 Status Report

    SciTech Connect (OSTI)

    Ward, Anderson L.; Gee, Glendon W.; Zhang, Z. F.; Keller, Jason M.

    2003-01-02

    This work reported here is part of the U. S. Department of Energy’s Science and Technology Initiative to develop improved conceptual models of flow and transport in the vadose zone, particularly for the Hanford Site, Washington. The National Academy of Sciences has identified significant knowledge gaps in conceptual model development as one reason for discovery of subsurface contamination in unexpected places. Inadequate conceptualizations limits, not only the understanding of long-term fate and transport, but also the selection and design of remediation technologies. Current conceptual models are limited partly because they do not account for the random heterogeneity that occurs under the extremes of very nonlinear flow behavior typical of the Hanford vadose zone. A major improvement in conceptual modeling of the Hanford vadose zone includes a better understanding and description of soil anisotropy, a property that appears to control much of the subsurface flow and transport in layered sediments at the Hanford Site.

  10. Coastal-zone biogeochemical dynamics under global warming

    SciTech Connect (OSTI)

    Mackenzie, F.T.; Ver, L.M.; Lerman, A.

    2000-03-01

    The coastal zone, consisting of the continental shelves to a depth of 200 meters, including bays, lagoons, estuaries, and near-shore banks, is an environment that is strongly affected by its biogeochemical and physical interactions with reservoirs in the adjacent domains of land, atmosphere, open ocean, and marine sediments. Because the coastal zone is smaller in volume and area coverage relative to the open ocean, it traditionally has been studied as an integral part of the global oceans. In this paper, the authors show by numerical modeling that it is important to consider the coastal zone as an entity separate from the open ocean in any assessment of future Earth-system response under human perturbation. Model analyses for the early part of the 21st century suggest that the coastal zone plays a significant modifying role in the biogeochemical dynamics of the carbon cycle and the nutrient cycles coupled to it. This role is manifested in changes in primary production, storage, and/or export of organic matter, its remineralization, and calcium carbonate precipitation--all of which determine the state of the coastal zone with respect to exchange of CO{sub 2} with the atmosphere. Under a scenario of future reduced or complete cessation of the thermohaline circulation (THC) of the global oceans, coastal waters become an important sink for atmospheric CO{sub 2}, as opposed to the conditions in the past and present, when coastal waters are believed to be a source of CO{sub 2} to the atmosphere. Profound changes in coastal-zone primary productivity underscore the important role of phosphorus as a limiting nutrient. In addition, calculations indicate that the saturation state of coastal waters with respect to carbonate minerals will decline by {approximately}15% by the year 2030. Any future slowdown in the THC of the oceans will increase slightly the rate of decline in saturation state.

  11. User Experiment Time-Line

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    User Experiment Time-Line Event Target Call for proposal 2 months before proposals are due PAC Proposals Due 7 weeks before PAC meeting TAC Report for PAC Proposals (includes Independent Technical Review) 4 weeks after proposals are due PAC Report Published 1-2 months after PAC

  12. FOAM: NOVEL DELIVERY TECHNOLOGY FOR REMEDIATION OF VADOSE ZONE ENVIRONMENTS

    SciTech Connect (OSTI)

    Jansik, Danielle P.; Wellman, Dawn M.; Mattigod, Shas V.; Zhong, Lirong; Wu, Yuxin; Foote, Martin; Zhang, Z. F.; Hubbard, Susan

    2011-07-05

    Deep vadose zone environments can be a primary source and pathway for contaminant migration to groundwater. These environments present unique characterization and remediation challenges that necessitate scrutiny and research. The thickness, depth, and intricacies of the deep vadose zone, combined with a lack of understanding of the key subsurface processes (e.g., biogeochemical and hydrologic) affecting contaminant migration, make it difficult to create validated conceptual and predictive models of subsurface flow dynamics and contaminant behavior across multiple scales. These factors also make it difficult to design and deploy sustainable remedial approaches and monitor long-term contaminant behavior after remedial actions. Functionally, the methods for addressing contamination must remove and/or reduce transport of contaminants. This problem is particularly challenging in the arid western United States where the vadose zone is hundreds of feet thick, rendering transitional excavation methods exceedingly costly and ineffective. Delivery of remedial amendments is one of the most challenging and critical aspects for all remedy-based approaches. The conventional approach for delivery is through injection of aqueous remedial solutions. However, heterogeneous deep vadose zone environments present hydrologic and geochemical challenges which limit the effectiveness. Because the flow of solution infiltration is dominantly controlled by gravity and suction, injected liquid preferentially percolates through highly permeable pathways, by-passing low-permeability zones which frequently contain the majority of contamination. Moreover, the wetting front can readily mobilize and enhance contaminant transport to the underlying aquifer prior to stabilization. Development of innovative, in-situ technologies may be the only way to meet remedial action objectives and long-term stewardship goals. Surfactants can be used to lower the liquid surface tension and create stabile foams, which readily penetrate low permeability zones. Although surfactant foams have been utilized for subsurface mobilization efforts in the oil and gas industry, so far, the concept of using foams as a delivery mechanism for transporting remedial amendments into deep vadose zone environments to stabilize metal and long-lived radionuclide contaminants has not been explored. Foam flow can be directed by pressure gradients, rather than being dominated by gravity; and, foam delivery mechanisms limit the volume of water (< 5% vol.) required for remedy delivery and emplacement, thus mitigating contaminant mobilization. We will present the results of a numerical modeling and integrated laboratory- / intermediate-scale investigation to simulate, develop, demonstrate, and monitor (i.e. advanced geophysical techniques and advanced predictive biomarkers) foam-based delivery of remedial amendments to remediate metals and radionuclides in vadose zone environments.

  13. Interactive display system having a scaled virtual target zone

    DOE Patents [OSTI]

    Veligdan, James T.; DeSanto, Leonard

    2006-06-13

    A display system includes a waveguide optical panel having an inlet face and an opposite outlet face. A projector and imaging device cooperate with the panel for projecting a video image thereon. An optical detector bridges at least a portion of the waveguides for detecting a location on the outlet face within a target zone of an inbound light spot. A controller is operatively coupled to the imaging device and detector for displaying a cursor on the outlet face corresponding with the detected location of the spot within the target zone.

  14. Particle denuded zones in alumina reinforced aluminum matrix composite weldments

    SciTech Connect (OSTI)

    Chidambaram, A.; Bhole, S.D.

    1996-08-01

    The Welding Institute of Canada (WIC), Ontario, has been studying the weldability of different DURALCAN MMC`s. Research on alumina reinforced (20 vol.%) 6061 Al alloy GTA welds showed satisfactory tensile and yield strengths (0.2% Proof Stress) but the welds failed to pass the bend test requirements with fracture taking place in the relatively brittle heat affected zone (HAZ). Further, the welds were characterized by a region which was devoid of reinforcement particles adjacent to the fusion lines. The present study was undertaken to try and explain the formation of this particle denuded zone (PDZ) at the fusion lines.

  15. A library of prompt detonation reaction zone data

    SciTech Connect (OSTI)

    Souers, P. C., LLNL

    1998-06-01

    Tables are given listing literature data that allows calculation of sonic reaction zones at or near steady-state for promptly detonating explosive cylinders. The data covers homogeneous, heterogeneous, composite, inorganic and binary explosives and allows comparison across the entire explosive field. Table 1 lists detonation front curvatures. Table 2 lists Size Effect data, i.e. the change of detonation velocity with cylinder radius. Table 3 lists failure radii and detonation velocities. Table 4 lists explosive compositions. A total of 51 references dating back into the 1950`s are given. Calculated reaction zones, radii of curvature and growth rate coefficients are listed.

  16. Date Times Group Speakers

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Meetings - Spring 2014 Date Times Group Speakers Tues, 1-13 2:30-3:30pm Faculty Meeting Fri, 1-24 12:30-1:30pm Group Research Meeting Emmanuel Giannelis Fri, 1-31 12:30-1:30pm Student & Postdoc Mtg Apostolos Enotiadis; Nikki Ritzert & Megan Holtz Fri, 2-7 12:30-1:30pm Group Research Meeting CHESS Mon, 2-10 2:30-3:30pm Faculty Meeting Will Dichtel Fri, 2-14 12:30-1:30pm Student & Postdoc Mtg Frank DiSalvo Fri, 2-21 12:30-1:30pm Group Research Meeting Lynden Archer Fri, 2-28

  17. UGE Scheduler Cycle Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    UGE Scheduler Cycle Time UGE Scheduler Cycle Time Genepool Cycle Time Genepool Daily Genepool Weekly Phoebe Cycle Time Phoebe Daily Phoebe Weekly What is the Scheduler Cycle? The...

  18. A saturated zone site-scale flow model for Yucca mountain

    SciTech Connect (OSTI)

    Eddebbarh, Al Aziz

    2008-01-01

    A saturated zone site-scale flow model (YMSZFM) was developed for licensing requirements for the Yucca Mountain nuclear waste repository to incorporate recent data and analyses including recent stratigraphic and water-level data from Nye County wells, single-and multiple-well hydraulic testing data, and recent hydrochemistry data. Analyses include use of data from the 2004 transient Death Valley Regional (ground-water) Flow System (DVRFS) model, the 2003 unsaturated zone flow model, and the latest hydrogeologic framework model (HFM). This model includes: (1) the latest understanding of SZ flow, (2) enhanced model validation and uncertainty analyses, (3) improved locations and definitions of fault zones, (4) refined grid resolution (500-to 250-m grid spacing), and (5) use of new data. The flow model was completed using the three-dimensional, Finite-Element Heat and Mass Transfer computer code (FEHM). The SZ site-scale flow model was calibrated with the commercial parameter estimation code, PEST to achieve a minimum difference between observed water levels and predicted water levels, and also between volumetric/mass flow rates along specific boundary segments as supplied by the DVRFS. A total of 161 water level and head measurements with varied weights were used for calibration. A comparison between measured water-level data and the potentiometric surface yielded an RMSE of 20.7 m (weighted RMSE of 8.8 m). The calibrated model was used to generate flow paths and specific discharge predictions. Model confidence was built by comparing: (l) calculated to observed hydraulic heads, and (2) calibrated to measured permeabilities (and therefore specific discharge). In addition, flowpaths emanating from below the repository footprint are consistent with those inferred both from gradients of measured head and from independent water-chemistry data. Uncertainties in the SZ site-scale flow model were quantified because all uncertainty contributes to inaccuracy in system representation and response. Null space and solution space uncertainties were determined.

  19. MOA-2011-BLG-293LB: First microlensing planet possibly in the habitable zone

    SciTech Connect (OSTI)

    Batista, V.; Gould, A.; Yee, J. C.; Gaudi, B. S. [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Beaulieu, J.-P. [Institut d'Astrophysique de Paris, 98 Bis Boulevard Arago, F-75014 Paris (France); Bennett, D. P. [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN 46556-5670 (United States); Fukui, A. [Okayama Astrophysical Observatory, National Astronomical Observatory of Japan, Asakuchi, Okayama 719-0232 (Japan); Sumi, T. [Department of Earth and Space Science, Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Udalski, A., E-mail: virginie@astronomy.ohio-state.edu, E-mail: gould@astronomy.ohio-state.edu, E-mail: jyee@astronomy.ohio-state.edu, E-mail: beaulieu@iap.fr, E-mail: bennett@nd.edu, E-mail: afukui@oao.nao.ac.jp, E-mail: sumi@ess.sci.osaka-u.ac.jp, E-mail: udalski@astrouw.edu.pl [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland)

    2014-01-01

    We used Keck adaptive optics observations to identify the first planet discovered by microlensing to lie in or near the habitable zone, i.e., at projected separation r = 1.1 ± 0.1 AU from its M{sub L} = 0.86 ± 0.06 M {sub ?} host, being the highest microlensing mass definitely identified. The planet has a mass m{sub p} = 4.8 ± 0.3 M {sub Jup}, and could in principle have habitable moons. This is also the first planet to be identified as being in the Galactic bulge with good confidence: D{sub L} = 7.72 ± 0.44 kpc. The planet/host masses and distance were previously not known, but only estimated using Bayesian priors based on a Galactic model. These estimates had suggested that the planet might be a super-Jupiter orbiting an M dwarf, a very rare class of planets. We obtained high-resolution JHK images using Keck adaptive optics to detect the lens and so test this hypothesis. We clearly detect light from a G dwarf at the position of the event, and exclude all interpretations other than that this is the lens with high confidence (95%), using a new astrometric technique. The calibrated magnitude of the planet host star is H{sub L} = 19.16 ± 0.13. We infer the following probabilities for the three possible orbital configurations of the gas giant planet: 53% to be in the habitable zone, 35% to be near the habitable zone, and 12% to be beyond the snow line, depending on the atmospherical conditions and the uncertainties on the semimajor axis.

  20. Isotope Geochemistry of Calcite Coatings and the Thermal History of the Unsaturated Zone at Yucca Mountain, Nevada

    SciTech Connect (OSTI)

    B.D. Marshall; J.F. Whelan

    2000-07-27

    Calcite and opal coatings found on fracture footwalls and lithophysal cavity bottoms in the volcanic section at Yucca Mountain (exposed in a tunnel) contain a record of gradual chemical and isotopic changes that have occurred in the unsaturated zone. The thin (less than 6 cm) coatings are composed primarily of calcite, opal, chalcedony, and quartz. Fluid inclusions in calcite that homogenize at greater than ambient temperatures provide impetus for geochronologic studies in order to determine the thermal history. In the welded Topopah Spring Tuff (12.7 Ma), U-Pb ages of opal and chalcedony layers provide evidence of a long history of deposition throughout the past 10 m.y. However, these ages can constrain the ages of associated calcite layers only in samples with an easily interpretable microstratigraphy. Strontium isotope ratios in calcite increase with microstratigraphic position from the base up to the outermost surface of the coatings. The strontium incorporated in these coatings records the systematic change in pore-water isotopic composition due to water-rock interaction primarily in the overlying nonwelded tuffs. A one-dimensional advection-reaction model simulates strontium isotope ratios measured in pore water extracted from core in three vertical boreholes adjacent to the tunnel. By calculating the strontium isotope compositions of the rocks at various past times, the model predicts a history of the strontium isotope ratios in the water that matches the record in the calcite and therefore provides approximate ages. Oxygen isotope ratios measured in calcite gradually increase with decreasing model strontium age. Assuming that the oxygen isotope ratio of the percolating water was relatively constant, this trend indicates a gradual cooling of the rocks over millions of years, in agreement with thermal modeling of magma beneath the 12-Ma Timber Mountain caldera just north of Yucca Mountain. This model predicts that temperatures significantly exceeding current geotherm values occurred prior to 6 Ma. We find no evidence for Quaternary or recent thermal perturbations to the cooling rocks.

  1. Vertical Variability in Saturated Zone Hydrochemistry Near Yucca Mountain, Nevada

    SciTech Connect (OSTI)

    G. Patterson; P. Striffler

    2007-02-17

    The differences in the saturated zone hydrochemistry with depth at borehole NC-EWDP-22PC reflect the addition of recharge along Fortymile Wash. The differences in water chemistry with depth at borehole NC-EWDP-19PB appear to indicate that other processes are involved. Water from the lower part of NC-EWDP-19PB possesses chemical characteristics that clearly indicate that it has undergone cation exchange that resulted in the removal of calcium and magnesium and the addition of sodium. This water is very similar to water from the Western Yucca Mountain facies that has previously been thought to flow west of NC-EWDP-19PB. Water from the lower zone in NC-EWDP-19PB also could represent water from the Eastern Yucca Mountain facies that has moved through clay-bearing or zeolitized aquifer material resulting in the altered chemistry. Water chemistry from the upper part of the saturated zone at NC-EWDP-19PB, both zones at NC-EWDP-22PC, and wells in the Fortymile Wash facies appears to be the result of recharge through the alluvium south of Yucca Mountain and within the Fortymile Wash channel.

  2. Archived Reference Climate Zone: 2B Phoenix, Arizona

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  3. Archived Reference Climate Zone: 2B Phoenix, Arizona

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  4. Archived Reference Climate Zone: 3C San Francisco, California

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  5. Archived Reference Climate Zone: 3C San Francisco, California

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  6. Archived Reference Climate Zone: 6B Helena, Montana

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  7. Archived Reference Climate Zone: 6B Helena, Montana

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  8. FORMATION OF CIRCUMBINARY PLANETS IN A DEAD ZONE

    SciTech Connect (OSTI)

    Martin, Rebecca G.; Armitage, Philip J. [JILA, University of Colorado and NIST, UCB 440, Boulder, CO 80309 (United States); Alexander, Richard D. [Department of Physics and Astronomy, University of Leicester, Leicester LE1 7RH (United Kingdom)

    2013-08-10

    Circumbinary planets have been observed at orbital radii where binary perturbations may have significant effects on the gas disk structure, on planetesimal velocity dispersion, and on the coupling between turbulence and planetesimals. Here, we note that the impact of all of these effects on planet formation is qualitatively altered if the circumbinary disk structure is layered, with a non-turbulent midplane layer (dead zone) and strongly turbulent surface layers. For close binaries, we find that the dead zone typically extends from a radius close to the inner disk edge up to a radius of around 10-20 AU from the center of mass of the binary. The peak in the surface density occurs within the dead zone, far from the inner disk edge, close to the snow line, and may act as a trap for aerodynamically coupled solids. We suggest that circumbinary planet formation may be easier near this preferential location than for disks around single stars. However, dead zones around wide binaries are less likely, and hence planet formation may be more difficult there.

  9. Archived Reference Climate Zone: 4A Baltimore, Maryland

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  10. Archived Reference Climate Zone: 4A Baltimore, Maryland

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  11. Archived Reference Climate Zone: 1A Miami, Florida

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  12. Archived Reference Climate Zone: 1A Miami, Florida

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  13. Archived Reference Climate Zone: 3B Los Angeles, California

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  14. Archived Reference Climate Zone: 3B Los Angeles, California

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  15. Archived Reference Climate Zone: 4B Albuquerque, New Mexico

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  16. Archived Reference Climate Zone: 4B Albuquerque, New Mexico

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  17. Archived Reference Climate Zone: 3B Las Vegas, Nevada

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  18. Archived Reference Climate Zone: 3B Las Vegas, Nevada

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  19. Effects of remediation amendments on vadose zone microorganisms

    SciTech Connect (OSTI)

    Miller, Hannah M.; Tilton, Fred A.

    2012-08-10

    Surfactant-based foam delivery technology has been studied to remediate Hanford 200 area deep vadose zone sediment. However, the surfactants and remediation amendments have an unknown effect on indigenous subsurface microorganisms. Microbial populations are important factors to consider in remediation efforts due to their potential to alter soil geochemistry. This project focuses on measuring microbial metabolic responses to remediation amendments in batch and column studies using Deep Vadose Zone Sediments. Initial studies of the microbes from Hanford 200 area deep vadose zone sediment showed surfactants sodium dodecyl sulfate (SDS) and cocamidopropyl betaine (CAPB) and remediation amendment calcium polysulfide (CPS) had no affect on microbial growth using BiologTM Ecoplates. To move towards a more realistic field analog, soil columns were packed with Hanford 200 Area sediment. Once microbial growth in the column was verified by observing growth of the effluent solution on tryptic soy agar plates, remedial surfactants were injected into the columns, and the resulting metabolic diversity was measured. Results suggest surfactant sodium dodecyl sulfate (SDS) stimulates microbial growth. The soil columns were also visualized using X-ray microtomography to inspect soil packing and possibly probe for evidence of biofilms. Overall, BiologTM Ecoplates provide a rapid assay to predict effects of remediation amendments on Hanford 200 area deep vadose zone microorganisms.

  20. CANDIDATE PLANETS IN THE HABITABLE ZONES OF KEPLER STARS

    SciTech Connect (OSTI)

    Gaidos, Eric

    2013-06-20

    A key goal of the Kepler mission is the discovery of Earth-size transiting planets in ''habitable zones'' where stellar irradiance maintains a temperate climate on an Earth-like planet. Robust estimates of planet radius and irradiance require accurate stellar parameters, but most Kepler systems are faint, making spectroscopy difficult and prioritization of targets desirable. The parameters of 2035 host stars were estimated by Bayesian analysis and the probabilities p{sub HZ} that 2738 candidate or confirmed planets orbit in the habitable zone were calculated. Dartmouth Stellar Evolution Program models were compared to photometry from the Kepler Input Catalog, priors for stellar mass, age, metallicity and distance, and planet transit duration. The analysis yielded probability density functions for calculating confidence intervals of planet radius and stellar irradiance, as well as p{sub HZ}. Sixty-two planets have p{sub HZ} > 0.5 and a most probable stellar irradiance within habitable zone limits. Fourteen of these have radii less than twice the Earth; the objects most resembling Earth in terms of radius and irradiance are KOIs 2626.01 and 3010.01, which orbit late K/M-type dwarf stars. The fraction of Kepler dwarf stars with Earth-size planets in the habitable zone ({eta}{sub Circled-Plus }) is 0.46, with a 95% confidence interval of 0.31-0.64. Parallaxes from the Gaia mission will reduce uncertainties by more than a factor of five and permit definitive assignments of transiting planets to the habitable zones of Kepler stars.

  1. An example of mixing-zone dolomite, Middle Eocene Avon Park Formation, Floridan aquifer system

    SciTech Connect (OSTI)

    Cander, H.S. )

    1994-07-01

    A late-formed dolomite cement in a core of the Middle Eocene Avon Park Formation, peninsular Florida, provides an example of dolomite cement from a mixing zone and illustrates how dolomite textural alteration and stabilization can occur at earth-surface conditions. The Avon Park Formation is a pervasively dolomitized peritidal platform carbonate 400 m thick in the Florida aquifer system. Typical Avon Park dolomite is inclusion-rich, fine-grained (< 40 mm), noncathodoluminescent, highly porous (average, 20%), and formed during the Eocene by normal to hypersaline seawater ([delta][sup 18]O = + 3.7[per thousand] PDB; [delta][sup 13]C = + 2.0[per thousand]; [sup 87]Sr/[sup 86]Sr = 0.70778; Sr = 167 ppm). In a 20 m interval in a core from southwest Florida, inclusion-free, cathodoluminescent dolomite overgrows the early-formed noncathodoluminescent marine dolomite. The cathodoluminescent dolomite cement profoundly alters the texture of Avon Park dolomite from typical Cenozoic-like porous, poorly crystalline dolomite to hard, dense, low-porosity, highly crystalline Paleozoic-like dolomite. The dolomite cement is not a replacement of limestone but an overgrowth of early-formed marine dolomite and pore-occluding cement. This study demonstrates that: (1) dolomite precipitated from a 75% seawater mixing-zone fluid that was both calcite saturated and sulfate-rich, and (2) dramatic textural maturation and stabilization in dolomite can occur in the near surface environment, without elevated temperature and burial conditions.

  2. Narrowing of the coherent population trapping resonance under zone pumping in cells with different characteristics of the wall coating

    SciTech Connect (OSTI)

    Kazakov, G A; Litvinov, A N; Matisov, B G [St. Petersburg State Polytechnic University, St. Petersburg (Russian Federation)

    2012-02-28

    It is shown that when coherent population trapping (CPT) resonance is excited by a narrow laser beam, the presence of elastic collisions with the cell wall significantly affects the line shape of the CPT-resonance. We have constructed a theoretical model, which is based on averaging over the random Ramsey sequences of the atom dwell time in the beam and dark zones and takes into account the probability of elastic bounce of an atom from the wall.

  3. Word Pro - S7

    U.S. Energy Information Administration (EIA) Indexed Site

    7. Electricity Figure 7.1 Electricity Overview (Billion ... Trade, 1949-2014 106 U.S. Energy Information Administration ... 200 300 400 500 Industrial 2015 2013 Industrial 2014 1950 ...

  4. Word Pro - S7

    U.S. Energy Information Administration (EIA) Indexed Site

    4 U.S. Energy Information Administration Monthly Energy ... Table 7.3b Consumption of Combustible Fuels for Electricity ... 50,537 7,849 29 220 266 127 2015 January ......

  5. FY 2006 Volume 7

    Energy Savers [EERE]

    7 February 2005 DOE/ME-0052 Volume 7 Interior & Related Agencies Fossil Energy Research & Development Naval Petroleum & Oil Shale Reserves Elk Hills School Lands Fund Energy Conservation Economic Regulation Strategic Petroleum Reserve Energy Information Administration Clean Coal Technology Department of Energy FY 2006 Congressional Budget Request Office of Management, Budget and Evaluation/CFO Volume 7 February 2005 DOE/ME-0052 Volume 7 Interior & Related Agencies Fossil Energy

  6. FY 2007 Volume 7

    Energy Savers [EERE]

    7 DOE/CF-008 Volume 7 Fossil energy and other Fossil energy research and development Naval petroleum & oil shale reserves Elk hills school lands fund Strategic petroleum reserve Clean coal technology Energy information administration Department of Energy FY 2007 Congressional Budget Request February 2006 Office of Chief Financial Officer Volume 7 DOE/CF-008 Volume 7 Printed with soy ink on recycled paper Fossil energy and other Fossil energy research and development Naval petroleum & oil

  7. FY 2008 Volume 7

    Energy Savers [EERE]

    7 DOE/CF-020 Volume 7 Fossil Energy and Other Fossil Energy Research and Development Naval Petroleum & Oil Shale Reserves Elk Hills School Lands Fund Strategic Petroleum Reserve Clean Coal Technology Ultra-Deepwater Unconventional Natural Gas Energy Information Administration Department of Energy FY 2008 Congressional Budget Request February 2007 Office of Chief Financial Officer Volume 7 DOE/CF-020 Volume 7 Fossil Energy and Other Fossil Energy Research and Development Naval Petroleum &

  8. FY 2009 Volume 7

    Energy Savers [EERE]

    7 DOE/CF-030 Volume 7 Fossil Energy Research and Development Naval Petroleum and Oil Shale Reserves Strategic Petroleum Reserve Northeast Home Heating Oil Reserve Clean Coal Technology Ultra-Deepwater Unconventional Natural Gas February 2008 Office of Chief Financial Officer Department of Energy FY 2009 Congressional Budget Request Volume 7 DOE/CF-030 Volume 7 Fossil Energy Research and Development Naval Petroleum and Oil Shale Reserves Strategic Petroleum Reserve Northeast Home Heating Oil

  9. FY 2012 Volume 7

    Energy Savers [EERE]

    3 Volume 7 Department of Energy FY 2012 Congressional Budget Request Nuclear Energy D f N l W t Di l Defense Nuclear Waste Disposal Nuclear Waste Disposal February 2011 Office of Chief Financial Officer Volume 7 Printed with soy ink on recycled paper Department of Energy/ Volume 7 FY 2012 Congressional Budget Volume 7 Table of Contents Page Appropriation Account Summary ........................................................................................................... 3 Nuclear Energy

  10. A = 7 General Tables

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 General Tables The General Table for 7He is subdivided into the following categories: Experimental Theoretical Model Calculations Hypernuclei and Mesons Pions The General Table for 7Li is subdivided into the following categories: Reviews Ground State Properties Shell Model Cluster Model Other Theoretical Work Model Calculations Photodisintegration Polarization Fission and Fusion Elastic and Inelastic Scattering Projectile Fragmentation and Multifragmentation Astrophysical Hyperfine Structure

  11. Extreme-UV lithography vacuum chamber zone seal

    DOE Patents [OSTI]

    Haney, Steven J. (Tracy, CA); Herron, Donald Joe (Manteca, CA); Klebanoff, Leonard E. (San Ramon, CA); Replogle, William C. (Livermore, CA)

    2003-04-15

    Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.

  12. Extreme-UV lithography vacuum chamber zone seal

    DOE Patents [OSTI]

    Haney, Steven J. (Tracy, CA); Herron, Donald Joe (Manteca, CA); Klebanoff, Leonard E. (San Ramon, CA); Replogle, William C. (Livermore, CA)

    2003-04-08

    Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.

  13. Extreme-UV lithography vacuum chamber zone seal

    DOE Patents [OSTI]

    Haney, Steven J. (Tracy, CA); Herron, Donald Joe (Manteca, CA); Klebanoff, Leonard E. (San Ramon, CA); Replogle, William C. (Livermore, CA)

    2001-01-01

    Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.

  14. Zone heated inlet ignited diesel particulate filter regeneration

    DOE Patents [OSTI]

    Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI

    2012-06-26

    An exhaust system that processes exhaust generated by an engine is provided. The system includes: a particulate filter (PF) that is disposed downstream of the engine and that filters particulates from the exhaust; and a grid that includes electrically resistive material that is segmented by non-conductive material into a plurality of zones and wherein the grid is applied to an exterior upstream surface of the PF.

  15. NASA Award for Marginal Ice Zone Observations and Process Experiment

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    (MIZOPEX) Award for Marginal Ice Zone Observations and Process Experiment (MIZOPEX) - Sandia Energy Energy Search Icon Sandia Home Locations Contact Us Employee Locator Energy & Climate Secure & Sustainable Energy Future Stationary Power Energy Conversion Efficiency Solar Energy Wind Energy Water Power Supercritical CO2 Geothermal Natural Gas Safety, Security & Resilience of the Energy Infrastructure Energy Storage Nuclear Power & Engineering Grid Modernization Battery

  16. 1999 vadose zone monitoring plan and guidance for subsequent years

    SciTech Connect (OSTI)

    Horton, D.G.; Reidel, S.P.; Last, G.V.

    1998-08-01

    The US Department of Energy`s Hanford Site has the most diverse and largest amounts of radioactive waste in the US. The majority of the liquid waste was disposed to the soil column where much of it remains today. This document provides the rationale and general framework for vadose zone monitoring at cribs, ditches, trenches and other disposal facilities to detect new sources of contamination and track the movement of existing contamination in the vadose zone for the protection of groundwater. The document provides guidance for subsequent site-specific vadose zone monitoring plans and includes a brief description of past vadose monitoring activities (Chapter 3); the results of the Data Quality Objective process used for this plan (Chapter 4); a prioritization of liquid waste disposal sites for vadose monitoring (Chapter 5 and Appendix B); a general Monitoring and Analysis Plan (Chapter 6); a general Quality Assurance Project Plan (Appendix A), and a description of vadose monitoring activities planned for FY 1999 (Appendix C).

  17. Multi-zone modelling of partially premixed low-temperature combustion in pilot-ignited natural-gas engines

    SciTech Connect (OSTI)

    Krishnan, S. R.; Srinivasan, K. K.

    2010-06-29

    Detailed results from a multi-zone phenomenological simulation of partially premixed advanced-injection low-pilot-ignited natural-gas low-temperature combustion are presented with a focus on early injection timings (the beginning of (pilot) injection (BOI)) and very small diesel quantities (2-3 per cent of total fuel energy). Combining several aspects of diesel and spark ignition engine combustion models, the closed-cycle simulation accounted for diesel autoignition, diesel spray combustion, and natural-gas combustion by premixed turbulent flame propagation. The cylinder contents were divided into an unburned zone, several pilot fuel zones (or 'packets') that modelled diesel evaporation and ignition, a flame zone for natural-gas combustion, and a burned zone. The simulation predicted the onset of ignition, cylinder pressures, and heat release rate profiles satisfactorily over a wide range of BOIs (20-60���° before top dead centre (before TDC)) but especially well at early BOIs. Strong coupling was observed between pilot spray combustion in the packets and premixed turbulent combustion in the flame zone and, therefore, the number of ignition centres (packets) profoundly affected flame combustion. The highest local peak temperatures (greater than 2000 K) were observed in the packets, while the flame zone was much cooler (about 1650 K), indicating that pilot diesel spray combustion is probably the dominant source of engine-out emissions of nitrogen oxide (NO x). Further, the 60���° before TDC BOI yielded the lowest average peak packet temperatures (about 1720 K) compared with the 20���° before TDC BOI (about 2480 K) and 40���° before TDC BOI (about 2700 K). These trends support experimental NO x trends, which showed the lowest NO x emissions for the 60���°, 20���°, and 40���° before TDC BOIs in that order. Parametric studies showed that increasing the intake charge temperature, pilot quantity, and natural-gas equivalence ratio all led to higher peak heat release rates and hotter packets but the pilot quantity and intake temperature affected the potential for NO x formation to a greater extent.

  18. Fact #889: September 7, 2015 Average Diesel Price Lower than...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    9: September 7, 2015 Average Diesel Price Lower than Gasoline for the First Time in Six Years Fact 889: September 7, 2015 Average Diesel Price Lower than Gasoline for the First...

  19. A geochemical model of the Kilauea east rift zone | Open Energy...

    Open Energy Info (EERE)

    rift zone Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: A geochemical model of the Kilauea east rift zone Abstract NA Author Donald Thomas...

  20. Deep Vadose Zone–Applied Field Research Initiative Fiscal Year 2012 Annual Report

    SciTech Connect (OSTI)

    Wellman, Dawn M.; Truex, Michael J.; Johnson, Timothy C.; Bunn, Amoret L.; Golovich, Elizabeth C.

    2013-03-14

    This annual report describes the background of the Deep Vadose Zone-Applied Field Research Initiative, and some of the programmatic approaches and transformational technologies in groundwater and deep vadose zone remediation developed during fiscal year 2012.

  1. Adams County, North Dakota ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Adams County, North Dakota ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Adams County, North Dakota ASHRAE Standard ASHRAE 169-2006 Climate...

  2. Aiken County, South Carolina ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Aiken County, South Carolina ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Aiken County, South Carolina ASHRAE Standard ASHRAE 169-2006 Climate...

  3. Vast Energy Resource in Residual Oil Zones, FE Study Says | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Vast Energy Resource in Residual Oil Zones, FE Study Says Vast Energy Resource in Residual Oil Zones, FE Study Says July 20, 2012 - 1:00pm Addthis Washington, DC - Billions of ...

  4. H.R.S. 205-5 - Zoning | Open Energy Information

    Open Energy Info (EERE)

    05-5 - Zoning Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- StatuteStatute: H.R.S. 205-5 - ZoningLegal Published NA Year Signed or Took Effect...

  5. Anson County, North Carolina ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Anson County, North Carolina ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Anson County, North Carolina ASHRAE Standard ASHRAE 169-2006 Climate...

  6. Ashe County, North Carolina ASHRAE 169-2006 Climate Zone | Open...

    Open Energy Info (EERE)

    Ashe County, North Carolina ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate Zone Place Ashe County, North Carolina ASHRAE Standard ASHRAE 169-2006 Climate...

  7. Energy Level Diagrams A=7

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 Available in the following years: (2002), (1988), (1984), (1979), (1974), (1966), (1959) A=7 Energy Level Diagrams from (2002TI10) GIF (Graphic Interchange Format): 7He (65 KB) 7Li (130 KB) 7Be (65 KB) Isobar Diagram (65 KB) PDF (Portable Document Format): 7He (35 KB) 7Li (65 KB) 7Be (65 KB) Isobar Diagram (65 KB) EPS (Encapsulated Postscript): 7He (1.7 MB) 7Li (1.8 MB) 7Be (1.6 MB) Isobar Diagram (1.6 MB) A=7 Energy Level Diagrams from (1988AJ01) GIF (Graphic Interchange Format): 7Li (80 KB)

  8. East Tennessee Technology Park Zones 1 and 2 | Department of Energy

    Office of Environmental Management (EM)

    Zones 1 and 2 East Tennessee Technology Park Zones 1 and 2 This document discusses the East Tennessee Technology Park's Zone 1 and 2. Topics include: * The area's safety * Any use limitations for the area * History and cleanup background for this area * How DOE's cleanup program addressed the problem PDF icon East Tennessee Technology Park Zone 1 & 2 fact sheet More Documents & Publications OREM Accomplishments Timeline EA-1175: Final Environmental Assessment (Addendum) EA-1640: Final

  9. Heterogeneous slip and rupture models of the San Andreas fault zone based upon three-dimensional earthquake tomography

    SciTech Connect (OSTI)

    Foxall, W.

    1992-11-01

    Crystal fault zones exhibit spatially heterogeneous slip behavior at all scales, slip being partitioned between stable frictional sliding, or fault creep, and unstable earthquake rupture. An understanding the mechanisms underlying slip segmentation is fundamental to research into fault dynamics and the physics of earthquake generation. This thesis investigates the influence that large-scale along-strike heterogeneity in fault zone lithology has on slip segmentation. Large-scale transitions from the stable block sliding of the Central 4D Creeping Section of the San Andreas, fault to the locked 1906 and 1857 earthquake segments takes place along the Loma Prieta and Parkfield sections of the fault, respectively, the transitions being accomplished in part by the generation of earthquakes in the magnitude range 6 (Parkfield) to 7 (Loma Prieta). Information on sub-surface lithology interpreted from the Loma Prieta and Parkfield three-dimensional crustal velocity models computed by Michelini (1991) is integrated with information on slip behavior provided by the distributions of earthquakes located using, the three-dimensional models and by surface creep data to study the relationships between large-scale lithological heterogeneity and slip segmentation along these two sections of the fault zone.

  10. Field evidence for strong chemical separation of contaminants inthe Hanford Vadose Zone

    SciTech Connect (OSTI)

    Conrad, Mark E.; DePaolo, Donald J.; Maher, Katharine; Gee,Glendon W.; Ward, Anderson L.

    2007-04-10

    Water and chemical transport from a point source withinvadose zone sediments at Hanford were examined with a leak testconsisting of five 3800-liter aliquots of water released at 4.5 m depthevery week over a 4-week period. The third aliquot contained bromide, D2Oand 87Sr. Movement of the tracers was monitored for 9 months by measuringpore water compositions of samples from boreholes drilled 2-8 m from theinjection point. Graded sedimentary layers acting as natural capillarybarriers caused significant lateral spreading of the leak water. D2Oconcentrations>50 percent of the concentration in the tracer aliquotwere detected at 9-11 m depth. However, increased water contents, lowerd18O values, and geophysical monitoring of moisture changes at otherdepths signified high concentrations of leak fluids were added where D2Oconcentrations were<3 percent above background, suggesting limitedmixing between different aliquots of the leak fluids. Initially highbromide concentrations decreased more rapidly over time than D2O,suggesting enhanced transport of bromide due to anion exclusion. Nosignificant increase in 87Sr was detected in the sampled pore water,indicating strong retardation of Sr by the sediments. These resultshighlight some of the processes strongly affecting chemical transport inthe vadose zone and demonstrate the significant separation of contaminantplumes that can occur.

  11. Flow and Transport in the Hanford 300 Area Vadose Zone-Aquifer-River System

    SciTech Connect (OSTI)

    Waichler, Scott R.; Yabusaki, Steven B.

    2005-07-13

    Contaminant migration in the 300 Area unconfined aquifer is strongly coupled to fluctuations in the Columbia River stage. To better understand the interaction between the river, aquifer, and vadose zone, a 2-D saturated-unsaturated flow and transport model was developed for a vertical cross-section aligned west-east across the Hanford Site 300 Area, nearly perpendicular to the river. The model was used to investigate water flow and tracer transport in the vadose zone-aquifer-river flow system, in support of the ongoing study of the 300 Area uranium plume. The STOMP simulator was used to model 1-year from 3/1/92 to 2/28/93, a period when hourly data were available for both groundwater and river levels. Net water flow to the river (per 1-meter width of shoreline) was 182 m3/y in the base case, but the cumulative exchange or total flow back and forth across the riverbed was 30 times greater. The low river case had approximately double the net water and Groundwater tracer flux into the river as compared to the base case.

  12. RSE Table 7.7 Relative Standard Errors for Table 7.7

    U.S. Energy Information Administration (EIA) Indexed Site

    7 Relative Standard Errors for Table 7.7;" " Unit: Percents." ,,,"Electricity","Components",,"Natural Gas","Components",,"Steam","Components" " "," ",,,,,,,,,,," " " "," ",,,"Electricity",,,"Natural Gas",,,"Steam" " "," ",,"Electricity","from Sources",,"Natural Gas","from

  13. 7He General Tables

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    He General Table The General Table for 7He is subdivided into the following categories: Experimental Theoretical Model Calculations Hypernuclei and Mesons Pions

  14. Word Pro - S7

    Gasoline and Diesel Fuel Update (EIA)

    7 Table 7.4a Consumption of Combustible Fuels for Electricity Generation and Useful Thermal Output: Total (All Sectors) (Sum of Tables 7.4b and 7.4c) Coal a Petroleum Natural Gas f Other Gases g Biomass Other j Distillate Fuel Oil b Residual Fuel Oil c Other Liquids d Petroleum Coke e Total e Wood h Waste i Thousand Short Tons Thousand Barrels Thousand Short Tons Thousand Barrels Billion Cubic Feet Trillion Btu 1950 Total .................... 91,871 5,423 69,998 NA NA 75,421 629 NA 5 NA NA 1955

  15. ARM - Hangman: Puzzle 7

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 Outreach Home Room News Publications Traditional Knowledge Kiosks Barrow, Alaska Tropical Western Pacific Site Tours Contacts Students Study Hall About ARM Global Warming FAQ Just for Fun Meet our Friends Cool Sites Teachers Teachers' Toolbox Lesson Plans Hangman: Puzzle 7 Clue: An estimate or prediction of future climate conditions

  16. RELAP-7 User's Guide

    SciTech Connect (OSTI)

    Zhang, Hongbin; Zhao, Haihua; Zou, Ling; Andrs, David; Berry, Ray Alden; Martineau, Richard Charles

    2014-12-01

    The document contains a user's guide on how to run the RELAP-7 code. The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory. RELAP-7 will become the main reactor systems simulation toolkit for the LWRS (Light Water Reactor Sustainability) program’s RISMC (Risk Informed Safety Margin Characterization) effort and the next generation tool in the RELAP reactor safety/systems analysis application series. RELAP-7 is written with object oriented programming language C++. A number of example problems and their associated input files are presented in this document to guide users to run the RELAP-7 code starting with simple pipe problems to problems with increasing complexity.

  17. Propagation direction reversal of ionization zones in the transition between high and low current magnetron sputtering

    SciTech Connect (OSTI)

    School of Materials Science and Engineering, State Key Lab for Materials Processing and Die & Mold Technology, Huazhong University of Science and Technology, Wuhan 430074, China; Department of Physics, University of California Berkeley, Berkeley, California 94720, USA; Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720, USA; Yang, Yuchen; Liu, Jason; Liu, Lin; Anders, André

    2014-12-11

    Past research has revealed the propagation of dense, asymmetric ionization zones in both high and low current magnetron discharges. Here we report about the direction reversal of ionization zone propagation as observed with fast cameras. At high currents, zones move in the E B direction with velocities of 103 to 104 m/s. However at lower currents, ionization zones are observed to move in the opposite, the -E B direction, with velocities ~;; 103 m/s. It is proposed that the direction reversal is associated with the local balance of ionization and supply of neutrals in the ionization zone.

  18. GLORIA mosaic of the U. S. Hawaiian exclusive economic zone

    SciTech Connect (OSTI)

    Torresan, M.E. )

    1990-06-01

    Digital long-range side-scan sonar reconnaissance surveys using GLORIA have imaged about 65% of the nearly 2.4 million km{sup 2} of the Hawaiian EEZ. The images have been processed and compiled into one mosaic that comprises the EEZ area surrounding the principal Hawaiian islands (from Hawaii to Kauai); extending on the south side of the ridge west to Kure Island, and on the north side to St. Rogatien Bank. The GLORIA images depict a variety of features that include enormous slumps and debris avalanches, lava flows, seafloor spreading fabric, fracture zones, seamounts, and unusual sedimentation patterns with more detail than previously had been possible with typical seismic reflection techniques. Some of these features were unknown before the GLORIA surveys. In particular, the GLORIA images show that the major degradational processes that affect the island and ridge areas are massive, likely tsunamogenic, blocky debris avalanches and slumps. These failures mantle the flanks of the ridge; some extending across the trough and up on to the Hawaiian Arch (up to 230 km from their sources). Over 30 failures are identified, ranging in area from 250 to > 6,000 km{sup 2} and having volumes from 500 to > 5,000 km{sup 3}. Such deposits cover > 125,000 km{sup 3} of the Ridge and adjacent seafloor. Also imaged are large Cenozoic submarine volcanic flow fields situated on the Hawaiian Arch. One such field, the North Arch field, is located north of Oahu between the Molokai and Murray fracture zones, and covers about 200,000 km{sup 2}. Prior to the GLORIA imagery only a small portion of this flow field was mapped. In addition, the imagery depicts the finer details of the Molokai and Murray fracture zones, the Cretaceous seafloor spreading fabric, and tensional faults on the Hawaiian Arch.

  19. Influence of compaction on the interfacial transition zone and the permeability of concrete

    SciTech Connect (OSTI)

    Leemann, Andreas . E-mail: andreas.leemann@empa.ch; Muench, Beat; Gasser, Philippe; Holzer, Lorenz

    2006-08-15

    The interfacial transition zone (ITZ) is regarded as a key feature for the transport properties and the durability of concrete. In this study one self-compacting concrete (SCC) mixture and two conventionally vibrated concrete (CVC) mixtures are studied in order to determine the influence of compaction on the porosity of the ITZ. Additionally oxygen permeability and water conductivity were measured in vertical and horizontal direction. The quantitative analysis of images made with an optical microscope and an environmental scanning electron microscope shows a significantly increased porosity and width of the ITZ in CVC compared to SCC. At the same time oxygen permeability and water conductivity of CVC are increased in comparison to SCC. Moreover, considerable differences in the porosity of the lower, lateral and upper ITZ are observed in both types of concrete. The anisotropic distribution of pores in the ITZ does not necessarily cause anisotropy in oxygen permeability and water conductivity though.

  20. ENVIRONMENTAL RADIATION MONITORING IN THE CHERNOBYL EXCLUSION ZONE - HISTORY AND RESULTS 25 YEARS AFTER

    SciTech Connect (OSTI)

    Farfan, E.; Jannik, T.

    2011-10-01

    This article describes results of the radiation environmental monitoring performed in the Chernobyl Exclusion Zone (ChEZ) during the period following the 1986 Chernobyl Nuclear Power Plant accident. This article presents a brief overview of five comprehensive reports generated under Contract No. DE-AC09-96SR18500 (Washington Savannah River Company LLC, Subcontract No. AC55559N, SOW No. ON8778) and summarizes characteristics of the ChEZ and its post-accident status and the history of development of the radiation monitoring research in the ChEZ is described. This article addresses characteristics of the radiation monitoring in the ChEZ, its major goals and objectives, and changes of these goals and objectives in the course of time, depending on the tasks associated with the phase of mitigation of the ChNPP accident consequences. The results of the radiation monitoring in the ChEZ during the last 25 years are also provided.

  1. T-TY Tank Farm Interim Surface Barrier Demonstration - Vadose Zone Monitoring FY10 Report

    SciTech Connect (OSTI)

    Zhang, Z. F.; Strickland, Christopher E.; Field, Jim G.; Parker, Danny L.

    2011-01-24

    The U.S. Department of Energy’s Office of River Protection has constructed interim surface barriers over a portion of the T and TY tank farms as part of the Interim Surface Barrier Demonstration Project. The interim surface barriers (hereafter referred to as the surface barriers or barriers) are designed to minimize the infiltration of precipitation into the soil zones containing radioactive contaminants and minimize the movement of the contaminants. As part of the demonstration effort, vadose zone moisture is being monitored to assess the effectiveness of the barriers at reducing soil moisture. Solar-powered systems were installed to continuously monitor soil water conditions at four locations in the T (i.e., instrument Nests TA, TB, TC, and TD) and the TY (i.e., instrument Nests TYA and TYB) Farms beneath the barriers and outside the barrier footprint as well as site meteorological conditions. Nests TA and TYA are placed in the area outside the barrier footprint and serve as controls, providing subsurface conditions outside the influence of the surface barriers. Nest TB provides subsurface measurements to assess surface-barrier edge effects. Nests TC, TD, and TYB are used to assess changes in soil-moisture conditions beneath the interim surface barriers. Except for occasional times for TC and TD and planned dates for TYB, during FY10, the battery voltage at the TMS and instrument Nests in both T and TY tank farms remained above 12.0 V, denoting that the battery voltages were sufficient for the stations to remain functional. All the HDUs were functioning normally, but some pressure-head values were greater than the upper measurement limit. The values that exceeded the upper limit may indicate wet soil conditions and/or measurement error, but they do not imply a malfunction of the sensors. Similar to FY07 through FY09, in FY10, the soil under natural conditions in the T Farm (Nest TA) was generally recharged during the winter period (October–March), and they discharged during the summer period (April–September). Soil water conditions above about 1.5-m to 2-m depth from all three types of measurements (i.e., CP, NP, and HDU) showed relatively large variation during the seasonal wetting-drying cycle. For the soil below 2-m depth, the seasonal variation of soil water content was relatively small. The construction of the TISB was completed in April 2008. In the soil below the TISB (Nests TC and TD), the CP-measured water content showed that ? at the soil between 0.6-m and 2.3-m depths was stable, indicating no climatic impacts on soil water conditions beneath the barrier. The NP-measured water content in the soil between about 3.4 m (11 ft) and 12.2 m (40 ft) since the completion of the barrier decreased by 0.007 to 0.014 m3 m-3. The HDU-measured soil-water pressure at 1-m, 2-m, and 5-m depths decreased by 0.7 to 2.4 m, indicating soil water drainage at these depths of the soil. In the soil below the edge of the TISB (Nest TB), the CP-measured water content was relatively stable through the year; the NP-measured water content showed that soil water drainage was occurring in the soil between about 3.4 m (11 ft) and 12.2 m (40 ft) but at a slightly smaller magnitude than in Nests TC and TD; the HDU-measurements show that the pressure head changes at Nest TB since the completion of the barrier were generally less than those at TC and TD, but more than those at TA. These results indicate that the TISB is performing as expected by intercepting the meteoric water from infiltrating into the soil, and the soil is becoming drier gradually. The barrier also had some effects on the soil below the barrier edge, but at a reduced magnitude. There was no significant difference in soil-water regime between the two nests in the TY tank farm because the barrier at the TY Farm was just completed one month before the end of the FY.

  2. TWRS vadose zone contamination issue expert panel report

    SciTech Connect (OSTI)

    Shafer, D.S.

    1997-05-01

    When members were first canvassed for participation in the Vadose Zone Expert Panel the stated purpose for convening the Panel was to review a controversial draft report, the SX Tank Farm Report. This report was produced by a DOE Grand Junction Project Office (GJPO) contractor, RUST Geotech, now MACTEC-ERS, for the DOE Richland Office (DOERL). Three meetings were planned for June, July and August, 1995 to review the draft report and to complete a Panel report by mid-September. The Expert Panel has found its efforts confounded by various non-technical issues. The Expert Panel has chosen to address some of the non-technical issues in this Preface rather than to dilute the technical discussion that follows in the body of this independent expert panel status report (Panel Report). Rather than performing a straightforward manuscript review, the Panel was asked to resolve conflicting interpretations of gamma-ray logging measurements performed in vadose zone boreholes (drywells) surrounding the high-level radioactive wastes of the SX tank farm. There are numerous and complex technical issues that must be evaluated before the vertical and radial extent of contaminant migration at the SX tank farm can be accurately assessed. When the Panel first met in early June, 1996, it quickly became apparent that the scientific and technical issues were obscured by policy and institutional affairs which have polarized discussion among various segments of the Hanford organization. This situation reflects the kinds of institutional problems described separately in reports by the National Research Council of the National Academy of Sciences (NAS/NRC), The Hanford Tanks Environmental Impacts and Policy Choices and BmTiers to Science: Technical Management of the Department of Energy Environmental Remediation Program. The Vadose Zone Characterization Program, appears to be caught between conflicting pressures and organizational mandates, some imposed from outside DOE-RL and some self-imposed. The institutional problems they encountered include having both Tank Waste Remediation System (TWRS), the parent organization of the Vadose Zone Characterization Program and Environmental Restoration (ER), each under different regulatory controls and different organizational units, seeking to defend the status quo and discount many of the Panel`s conclusions and recommendations. The results presented in the SX Tank Farm Report, especially the visualizations, have created concern in the public sector, both on a local, personal level and on a national political level.

  3. Wireless zoned particulate matter filter regeneration control system

    DOE Patents [OSTI]

    Gonze, Eugene V [Pinckney, MI; Kirby, Kevin W [Calabasas Hills, CA; Phelps, Amanda [Malibu, CA

    2011-10-04

    An assembly includes a particulate matter (PM) filter that comprises an upstream end for receiving exhaust gas, a downstream end and multiple zones. An absorbing layer absorbs microwave energy in one of N frequency ranges and is arranged with the upstream end. N is an integer. A frequency selective filter has M frequency selective segments and receives microwave energy in the N frequency ranges. M is an integer. One of the M frequency selective segments permits passage of the microwave energy in one of the N frequency ranges and does not permit passage of microwave energy in the other of the N frequency ranges.

  4. Method for continuously recovering metals using a dual zone chemical reactor

    DOE Patents [OSTI]

    Bronson, Mark C. (Livermore, CA)

    1995-01-01

    A dual zone chemical reactor continuously processes metal-containing materials while regenerating and circulating a liquid carrier. The starting materials are fed into a first reaction zone of a vessel containing a molten salt carrier. The starting materials react to form a metal product and a by-product that dissolves in the molten salt that flows to a second reaction zone in the reaction vessel. The second reaction zone is partitioned from, but in fluid communication with, the first reaction zone. The liquid carrier continuously circulates along a pathway between the first reaction zone and the second reaction zone. A reactive gas is introduced into the second reaction zone to react with the reaction by-product to generate the molten salt. The metal product, the gaseous waste products, and the excess liquid carrier are removed without interrupting the operation of the reactor. The design of the dual zone reactor can be adapted to combine a plurality of liquid carrier regeneration zones in a multiple dual zone chemical reactor for production scale processing.

  5. Method for continuously recovering metals using a dual zone chemical reactor

    DOE Patents [OSTI]

    Bronson, M.C.

    1995-02-14

    A dual zone chemical reactor continuously processes metal-containing materials while regenerating and circulating a liquid carrier. The starting materials are fed into a first reaction zone of a vessel containing a molten salt carrier. The starting materials react to form a metal product and a by-product that dissolves in the molten salt that flows to a second reaction zone in the reaction vessel. The second reaction zone is partitioned from, but in fluid communication with, the first reaction zone. The liquid carrier continuously circulates along a pathway between the first reaction zone and the second reaction zone. A reactive gas is introduced into the second reaction zone to react with the reaction by-product to generate the molten salt. The metal product, the gaseous waste products, and the excess liquid carrier are removed without interrupting the operation of the reactor. The design of the dual zone reactor can be adapted to combine a plurality of liquid carrier regeneration zones in a multiple dual zone chemical reactor for production scale processing. 6 figs.

  6. UGE Scheduler Cycle Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    UGE Scheduler Cycle Time UGE Scheduler Cycle Time Genepool Cycle Time Genepool Daily Genepool Weekly Phoebe Cycle Time Phoebe Daily Phoebe Weekly What is the Scheduler Cycle? The Univa Grid Engine Scheduler cycle performs a number of important tasks, including: Prioritizing Jobs Reserving Resources for jobs requesting more resources (slots / memory) Dispatching jobs or tasks to the compute nodes Evaluating job dependencies The "cycle time" is the length of time it takes the scheduler

  7. Code System Calculate One-Dimensional Vertical Transport Unsaturated Soil Zone

    Energy Science and Technology Software Center (OSTI)

    1989-03-01

    SESOIL, as an integrated screening-level soil compartment model, is designed to simultaneously model water transport, sediment transport, and pollutant fate. SESOIL is a one-dimensional vertical transport model for the unsaturated soil zone. Only one compound at a time can be considered. The model is based on mass balance and equilibrium partitioning of the chemical between different phases (dissolved, sorbed, vapor, and pure). The SESOIL model was designed to perform long-term simulations of chemical transport andmore » transformations in the soil and uses theoretically derived equations to represent water transport, sediment transport on the land surface, pollutant transformation, and migration of the pollutant to the atmosphere and groundwater. Climatic data, compartment geometry, and soil and chemical property data are the major components used in the equations. SESOIL was developed as a screening-level model, utilizing less soil, chemical, and meteorological values as input than most other similar models. Output of SESOIL includes time-varying pollutant concentrations at various soil depths and pollutant loss from the unsaturated zone in terms of surface runoff, percolation to the groundwater, volatilization, and degradation. The February 1995 release corrects an error that caused the code to fail when average monthly air temperature was -10C and includes an improved iteration procedure for the mass balance equations in the model. PLEASE NOTE: The RISKPRO information management software (see OTHER PROG/OPER SYS INFO) was used by the developers of the New SESOIL User''s Guide in their study and revisions of SESOIL. Using RISKPRO in conjunction with SESOIL is an option, and it may provide the easiest way to use SESOIL. The other option, use of SESOIL in stand-alone mode, has been tested and used. The stand-alone option is covered in ''Instructions for Running Stand-Alone SESOIL Code'', and in ''A Seasonal Soil Compartment Model''.« less

  8. Word Pro - S7

    Gasoline and Diesel Fuel Update (EIA)

    9 Table 7.2a Electricity Net Generation: Total (All Sectors) (Sum of Tables 7.2b and 7.2c; Million Kilowatthours) Fossil Fuels Nuclear Electric Power Hydro- electric Pumped Storage e Renewable Energy Total j Coal a Petro- leum b Natural Gas c Other Gases d Conven- tional Hydro- electric Power f Biomass Geo- thermal Solar/ PV i Wind Wood g Waste h 1950 Total .............. 154,520 33,734 44,559 NA 0 f ( ) 100,885 390 NA NA NA NA 334,088 1955 Total .............. 301,363 37,138 95,285 NA 0 f ( )

  9. Word Pro - S7

    Gasoline and Diesel Fuel Update (EIA)

    3 Table 7.3a Consumption of Combustible Fuels for Electricity Generation: Total (All Sectors) (Sum of Tables 7.3b and 7.3c) Coal a Petroleum Natural Gas f Other Gases g Biomass Other j Distillate Fuel Oil b Residual Fuel Oil c Other Liquids d Petroleum Coke e Total e Wood h Waste i Thousand Short Tons Thousand Barrels Thousand Short Tons Thousand Barrels Billion Cubic Feet Trillion Btu 1950 Total .................... 91,871 5,423 69,998 NA NA 75,421 629 NA 5 NA NA 1955 Total ....................

  10. 7Li Cross Section

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    p, X) (Current as of 12162015) NSR Reaction Ep (MeV) Cross Section File X4 Dataset Date Added 1997GO13 7Li(pol. p, ): total , S-factor for capture to third-excited state 0 -...

  11. Word Pro - S7

    U.S. Energy Information Administration (EIA) Indexed Site

    Energy Information Administration Monthly Energy Review February 2016 Table 7.2b Electricity Net Generation: ... 17,304 181,496 3,937,003 2015 January ...... 131,465 ...

  12. Word Pro - S7

    U.S. Energy Information Administration (EIA) Indexed Site

    8 U.S. Energy Information Administration Monthly Energy ... Table 7.4b Consumption of Combustible Fuels for Electricity ... 52,235 8,146 44 251 279 137 2015 January ......

  13. Building America Best Practices Series, Volume 7.3: Guide to Determining

    Energy Savers [EERE]

    Climate Regions by County | Department of Energy Series, Volume 7.3: Guide to Determining Climate Regions by County Building America Best Practices Series, Volume 7.3: Guide to Determining Climate Regions by County This report describes the climate zone designations used by the U.S. Department of Energy Building America Program, and is intended to help builders to identify the appropriate climate designation for the counties in which they are building. PDF icon Guide to Determining Climate

  14. Halloween (+7 Days) | Department of Energy

    Energy Savers [EERE]

    Halloween (+7 Days) Halloween (+7 Days) November 7, 2011 - 1:34pm Addthis Drew Bittner Writer/Editor, Office of Energy Efficiency and Renewable Energy Well, it's now a week after All Hallow's Eve. If you're like my family, most of the candy's been eaten and you're down to that last half-crushed chocolate bar or licorice stick, as well as seeing the discarded bits of costume still here and there-my daughter's having a hard time giving up her night as a superhero. Walking around while my girl went

  15. jul10_Times.indd

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 July 2010 www.y12.doe.gov/news/times.php P.O. Box 2009 Oak Ridge, TN 37831-8245 W H A T ' S I N S I D E Page 2 Want to know about Y-12's budget? Read what Darrel Kohlhorst said. Page 3 Y-12 employees get a LIFE Center Pages 4 and 5 Safeguards, Security and Emergency Services' Sentinel Page 6 Employees raise money for Relay for Life Page 8 Refl ections of Y-12's history B&W Technical Services Y-12, LLC, a partnership between Babcock & Wilcox Technical Services Group Inc. and Bechtel

  16. When did movement begin on the Furnace Creek fault zone

    SciTech Connect (OSTI)

    Reheis, M. )

    1993-04-01

    About 50 km of post-Jurassic right-lateral slip has occurred on the northern part of the Furnace Creek fault zone (FCFZ). The sedimentology, stratigraphy, and structure of Tertiary rocks suggest that movement on the fault began no earlier than 12--8 Ma and possibly as late as 5--4 Ma. Large remnants of erosion surfaces occur on both sides of the FCFZ in the southern White Mountains and Fish Lake Valley and are buried by rhyolite and basalt, mostly 12--10 Ma; the ash flows and welded tuffs were likely erupted from sources at least 40 km to the east. Thus, the area probably had gentle topography, suggesting a lengthy period of pre-late Miocene tectonic stability. On the west side of the FCFZ, Cambrian sedimentary rocks are buried by a fanglomerate with an [sup [minus

  17. Analysis of offsite Emergency Planning Zones for Rocky Flats Plant

    SciTech Connect (OSTI)

    Inger, J.R. ); Brown-Strattan, M.A. . Rocky Flats Plant)

    1991-01-01

    The purpose of this quality assurance program was to ensure the quality and technical adequacy of Phase 2 of the Analysis of Offsite Emergency Planning Zones (EPZ) for the Rocky Flats Plant project. Quality assurance was accomplished by managing and controlling the processes in the development of the product. The quality assurance task team conducted audits, reviews, and surveillances of project and related activities. This process contributed to identifying areas where the quality assurance plan was not fully implemented, areas needing improvement, and/or corrective actions resulting in a improved product. During the reviews and audits, several key areas were identified where quality assurance plan implementation needed to be improved. These areas included maintaining adequate documentation, reviewing technical results, making inputs traceable to technical results, and understanding that all personnel are responsible for quality.

  18. Results of U-xMo (x=7, 10, 12 wt.%) Alloy versus Al-6061 Cladding Diffusion Couple Experiments Performed at 500, 550 and 600 Degrees C

    SciTech Connect (OSTI)

    Emmanuel Perez; Dennis D. Keiser, Jr.; Yongho Sohn

    2013-04-01

    The Reduced Enrichment for Research and Test Reactors (RERTR) program has been developing low enrichment fuel systems encased in Al 6061 for use in research and test reactors. U–Mo alloys in contact with Al and Al alloys can undergo diffusional interactions that can result in the development of interdiffusion zones with complex fine-grained microstructures composed of multiple phases. A monolithic fuel currently being developed by the RERTR program has local regions where the U–Mo fuel plate is in contact with the Al 6061 cladding and, as a result, the program finds information about interdiffusion zone development at high temperatures of interest. In this study, the microstructural development of diffusion couples consisting of U-7wt.%Mo, U-10wt.%Mo, and U-12wt.%Mo vs. Al 6061 (or 6061 aluminum) cladding, annealed at 500, 550, 600 degrees C for 1, 5, 20, 24, or 132 hours, was analyzed by backscatter electron microscopy and x-ray energy dispersive spectroscopy on a scanning electron microscope. Concentration profiles were determined by standardized wavelength dispersive spectroscopy and standardless x-ray energy dispersive spectroscopy. The results of this work shows that the presence of surface layers at the U–Mo/Al 6061 interface can dramatically impact the overall interdiffusion behavior in terms of rate of interaction and uniformity of the developed interdiffusion zones. It further reveals that relatively uniform interaction layers with higher Si concentrations can develop in U–Mo/Al 6061 couples annealed at shorter times and that longer times at temperature result in the development of more non-uniform interaction layers with more areas that are enriched in Al. At longer annealing times and relatively high temperatures, U–Mo/Al 6061 couples can exhibit more interaction compared to U–Mo/pure Al couples. The minor alloying constituents in Al 6061 cladding can result in the development of many complex phases in the interaction layer of U–Mo/Al–6061 cladding couples, and some phases in the interdiffusion zones of U–Mo/Al–6061 cladding couples are likely similar to those observed for U–Mo/pure Al couples.

  19. Domoic acid production near California coastal upwelling zones, June 1998

    SciTech Connect (OSTI)

    Trainer, V L. (National Marine Fisheries Service); Adams, Nicolaus G. (National Marine Fisheries Service); Bill, Brian D. (National Marine Fisheries Service); Stehr, Carla M. (National Marine Fisheries Service); Wekell, John C. (National Marine Fisheries Service); Moeller, Peter (National Ocean Service, Marine Biotoxins Program); Busman, Mark (National Ocean Service, Marine Biotoxins Program); Woodruff, Dana L. (BATTELLE (PACIFIC NW LAB))

    2000-01-01

    Sea lion mortalities in central California during May and June 1998 were traced to their ingestion of sardines and anchovies that had accumulated the neurotoxin domoic acid. The detection of toxin in urine, feces, and stomach contents of several sea lions represents the first proven occurrence of domoic acid transfer through the food chain to a marine mammal. The pennate diatoms, Pseudo-nitzschia multiseries and P. australis, were the dominant, toxin-producing phytoplankton constituting algal blooms near Monterey Bay, Half Moon Bay, and Oceano Dunes, areas where sea lions with neurological symptoms stranded. Toxic Pseudo-nitzschia were also found near Morrow Bay, Point Conception, Point Arguello, and Santa Barbara, demonstrating that these species were widespread along the central California coast in June 1998. Measurements of domoic acid during three cruises in early June showed the highest cellular toxin levels in P. multiseries near Point A?o Nuevo and in P. australis from Morro w Bay. Maximum cellular domoic acid levels were observed within 20 km of the coast between 0 and 5 m depth, although toxin was also measured to depths of 40 m. Hydrographic data indicated that the highest toxin levels and greatest numbers of toxic cells were positioned in water masses associated with upwelling zones near coastal headlands. Nutrient levels at these sites were less than those typically measured during periods of active upwelling, due to the 1998 El Ni?o event. The flow of cells and/or nutrients from coastal headlands into embayments where cells can multiply in a stratified environment is a possible mechanism of bloom development along the central California coast. This coupling of toxic Pseudo-nitzschia growth near upwelling zones with physical processes involved in cell transport will be understood only when long-term measurements are made at several key coastal locations, aiding in our capability to predict domoic-acid producing algal blooms.

  20. Technical and Policy Challenges in Deep Vadose Zone Remediation of Metals and Radionuclides

    SciTech Connect (OSTI)

    Wellman, Dawn M.; Truex, Michael J.; Freshley, Mark D.; Dresel, P. E.; Cantrell, Kirk J.

    2012-03-21

    Deep vadose zone contamination is a significant issue facing the U.S. Department of Energy’s (DOE) Office of Environmental Management (EM). Contamination in the deep vadose zone is isolated from exposure such that direct contact is not a factor in risk to human health and the environment; rather, movement of contamination from the deep vadose zone to the groundwater creates the potential for exposure and risk to receptors. Transport of deep vadose zone contamination and discharge to the groundwater creates the potential for exposure and risk to receptors, so limiting flux to groundwater is key for protection of groundwater resources. Remediation approaches for the deep vadose zone need to be considered within the regulatory context, targeted at mitigating the source of contamination and reduce contaminant flux to groundwater. This paper reviews the processes for deep vadose zone metal and radionuclide remediation as well as challenges and opportunities for implementation.

  1. Variable power distribution for zoned regeneration of an electrically heated particulate filter

    DOE Patents [OSTI]

    Bhatia, Garima [Bangalore, IN; Gonze, Eugene V [Pinckney, MI

    2012-04-03

    A system includes a particulate matter (PM) filter with multiple zones, an electric heater and a control module. The electrical heater includes heater segments, which each correspond with a respective one of the zones. The electrical heater is arranged upstream from and is proximate with the PM filter. The control module selectively applies a first energy level to a first one of the zones via a first one of the heater segments to initiate regeneration in the first zone. The control module also selectively applies a second energy level that is less than the first energy level to a second one of the zones via a second one of the heater segments to initiate regeneration in the second zone.

  2. Exploring the blazar zone in high-energy flares of FSRQs

    SciTech Connect (OSTI)

    Pacciani, L.; Donnarumma, I.; Tavecchio, F.; Stamerra, A.; Carrasco, L.; Recillas, E.; Porras, A.; Uemura, M.

    2014-07-20

    The gamma-ray emission offers a powerful diagnostic tool to probe jets and their surroundings in flat-spectrum radio quasars (FSRQs). In particular, sources emitting at high energies (>10 GeV) give us the strongest constraints. This motivates us to start a systematic study of flares with bright emission above 10 GeV, examining archival data of the Fermi-LAT gamma-ray telescope. At the same time, we began to trigger Target of Opportunity observations to the Swift observatory at the occurrence of high-energy flares, obtaining a wide coverage of the spectral energy distributions (SEDs) for several FSRQs during flares. Among others, we investigate the SED of a peculiar flare of 3C 454.3, showing a remarkably hard gamma-ray spectrum, quite different from the brightest flares of this source, and a bright flare of CTA 102. We modeled the SED in the framework of the one-zone leptonic model, using also archival optical spectroscopic data to derive the luminosity of the broad lines and thus estimate the disk luminosity, from which the structural parameters of the FSRQ nucleus can be inferred. The model allowed us to evaluate the magnetic field intensity in the blazar zone and to locate the emitting region of gamma-rays in the particular case in which gamma-ray spectra show neither absorption from the broad-line region (BLR) nor the Klein-Nishina curvature expected in leptonic models assuming the BLR as the source of seed photons for the External Compton scenario. For FSRQs bright above 10 GeV, we were able to identify short periods lasting less than one day characterized by a high rate of high-energy gamma-rays and hard gamma-ray spectra. We discussed the observed spectra and variability timescales in terms of injection and cooling of energetic particles, arguing that these flares could be triggered by magnetic reconnection events or turbulence in the flow.

  3. Notice of construction for tank waste remediation system vadose zone characterization

    SciTech Connect (OSTI)

    HILL, J.S.

    1999-05-04

    The following description and any attachments and references are provided to the Washington State Department of Health (WDOH), Division of Radiation Protection, Air Emissions & Defense Waste Section as a notice of constriction (NOC) in accordance with Washington Administrative Code (WAC) 246-247, Radiation Protection - Air Emissions. The WAC 246-247-060, ''Applications, registration, and licensing'', states ''This section describes the information requirements for approval to construct, modify, and operate an emission unit. Any NOC requires the submittal of information listed in Appendix A.'' Appendix A (WAC 246-247-1 10) lists the requirements that must be addressed. Additionally, the following description, attachments and references are provided to the U.S. Environmental Protection Agency (EPA) as an NOC, in accordance with Title 40 Code of Federal Regulations (CFR), Part 61, ''National Emission Standards for Hazardous Air Pollutants.'' The information required for submittal to the EPA is specified in 40 CFR 61.07. The potential emissions from this activity are estimated to provide less than 0.1 millirem/year total effective dose equivalent (TEDE) to the hypothetical offsite maximally exposed individual (MEI), and commencement is needed within a short time frame. Therefore, this application is also intended to provide notification of the anticipated date of initial startup in accordance with the requirement listed in 40 CFR 61.09(a)(1), and it is requested that approval of this application will also constitute EPA acceptance of this initial start-up notification. Written notification of the actual date of initial startup, in accordance with the requirement listed in 40 CFR 61.09(a)(2) will be provided at a later date. This NOC covers the activities associated with vadose zone characterization within the Single-Shell Tank Farms located in the 200-East and 200-West Areas of the Hanford Site. Vadose zone characterization activities include the drilling and sampling of soil from the surface to the depth of groundwater.

  4. The Y-12 Times

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    The comings and goings during June Page 7 Y-12's new talent Ray Smith Donna Watson Bill ... than 400 people toured Y-12," said Ray Smith, site historian. "At the end of the day, ...

  5. Time of Flight

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    beam is pulsed, the energy of the neutrons that are produced can be determined by Time-of-Flight (TOF) techniques. Neutron Time-of-Flight Since the LANSCE proton beam is...

  6. Word Pro - S7

    Gasoline and Diesel Fuel Update (EIA)

    5 Table 7.3c Consumption of Selected Combustible Fuels for Electricity Generation: Commercial and Industrial Sectors (Subset of Table 7.3a) Commercial Sector a Industrial Sector b Coal c Petroleum d Natural Gas e Biomass Coal c Petroleum d Natural Gas e Other Gases g Biomass Other i Waste f Wood h Waste f Thousand Short Tons Thousand Barrels Billion Cubic Feet Trillion Btu Thousand Short Tons Thousand Barrels Billion Cubic Feet Trillion Btu 1990 Total .................... 417 953 28 15 10,740

  7. Word Pro - S7

    Gasoline and Diesel Fuel Update (EIA)

    19 Table 7.4c Consumption of Selected Combustible Fuels for Electricity Generation and Useful Thermal Output: Commercial and Industrial Sectors (Subset of Table 7.4a) Commercial Sector a Industrial Sector b Coal c Petroleum d Natural Gas e Biomass Coal c Petroleum d Natural Gas e Other Gases g Biomass Other i Waste f Wood h Waste f Thousand Short Tons Thousand Barrels Billion Cubic Feet Trillion Btu Thousand Short Tons Thousand Barrels Billion Cubic Feet Trillion Btu 1990 Total

  8. Word Pro - S7

    Gasoline and Diesel Fuel Update (EIA)

    7 Table 7.1 Electricity Overview (Billion Kilowatthours) Net Generation a Trade T&D Losses f and Unaccounted for g End Use Electric Power Sector b Com- mercial Sector c Indus- trial Sector d Total Imports e Exports e Net Imports e Retail Sales h Direct Use i Total 1950 Total .................... 329 NA 5 334 2 (s) 2 44 291 NA 291 1955 Total .................... 547 NA 3 550 5 (s) 4 58 497 NA 497 1960 Total .................... 756 NA 4 759 5 1 5 76 688 NA 688 1965 Total ....................

  9. Word Pro - S7

    Gasoline and Diesel Fuel Update (EIA)

    1 Table 7.2c Electricity Net Generation: Commercial and Industrial Sectors (Subset of Table 7.2a; Million Kilowatthours) Commercial Sector a Industrial Sector b Coal c Petro- leum d Natural Gas e Biomass Total g Coal c Petro- leum d Natural Gas e Other Gases h Hydro- electric Power i Biomass Total k Waste f Wood j Waste f 1950 Total .................... NA NA NA NA NA NA NA NA NA 4,946 NA NA 4,946 1955 Total .................... NA NA NA NA NA NA NA NA NA 3,261 NA NA 3,261 1960 Total

  10. Estimation of unsaturated zone traveltimes for Rainier Mesa and Shoshone Mountain, Nevada Test Site, Nevada, using a source-responsive preferential-flow model

    SciTech Connect (OSTI)

    Brian A. Ebel; John R. Nimmo

    2009-09-11

    Traveltimes for contaminant transport by water from a point in the unsaturated zone to the saturated zone are a concern at Rainier Mesa and Shoshone Mountain in the Nevada Test Site, Nevada. Where nuclear tests were conducted in the unsaturated zone, contaminants must traverse hundreds of meters of variably saturated rock before they enter the saturated zone in the carbonate rock, where the regional groundwater system has the potential to carry them substantial distances to a location of concern. The unsaturated-zone portion of the contaminant transport path may cause a significant delay, in addition to the time required to travel within the saturated zone, and thus may be important in the overall evaluation of the potential hazard from contamination. Downward contaminant transport through the unsaturated zone occurs through various processes and pathways; this can lead to a broad distribution of contaminant traveltimes, including exceedingly slow and unexpectedly fast extremes. Though the bulk of mobile contaminant arrives between the time-scale end members, the fastest contaminant transport speed, in other words the speed determined by the combination of possible processes and pathways that would bring a measureable quantity of contaminant to the aquifer in the shortest time, carries particular regulatory significance because of its relevance in formulating the most conservative hazard-prevention scenarios. Unsaturated-zone flow is usually modeled as a diffusive process responding to gravity and pressure gradients as mediated by the unsaturated hydraulic properties of the materials traversed. The mathematical formulation of the diffuse-flow concept is known as Richards' equation, which when coupled to a solute transport equation, such as the advection-dispersion equation, provides a framework to simulate contaminant migration in the unsaturated zone. In recent decades awareness has increased that much fluid flow and contaminant transport within the unsaturated zone takes place as preferential flow, faster than would be predicted by the coupled Richards' and advection-dispersion equations with hydraulic properties estimated by traditional means. At present the hydrologic community has not achieved consensus as to whether a modification of Richards' equation, or a fundamentally different formulation, would best quantify preferential flow. Where the fastest contaminant transport speed is what needs to be estimated, there is the possibility of simplification of the evaluation process. One way of doing so is by a two-step process in which the first step is to evaluate whether significant preferential flow and solute transport is possible for the media and conditions of concern. The second step is to carry out (a) a basic Richards' and advection-dispersion equation analysis if it is concluded that preferential flow is not possible or (b) an analysis that considers only the fastest possible preferential-flow processes, if preferential flow is possible. For the preferential-flow situation, a recently published model describable as a Source-Responsive Preferential-Flow (SRPF) model is an easily applied option. This report documents the application of this two-step process to flow through the thick unsaturated zones of Rainier Mesa and Shoshone Mountain in the Nevada Test Site. Application of the SRPF model involves distinguishing between continuous and intermittent water supply to preferential flow paths. At Rainier Mesa and Shoshone Mountain this issue is complicated by the fact that contaminant travel begins at a location deep in the subsurface, where there may be perched water that may or may not act like a continuous supply, depending on such features as the connectedness of fractures and the nature of impeding layers. We have treated this situation by hypothesizing both continuous and intermittent scenarios for contaminant transport to the carbonate aquifer and reporting estimation of the fastest speed for both of these end members.

  11. Time-Resolved

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and time) three correspond to the three broad categories of synchrotron experimental measurement techniques: spectroscopy (energy), scattering (momentum), and imaging...

  12. DOE to Invest up to $2.3 Million to Identify Renewable Energy Zones in

    Energy Savers [EERE]

    Western States | Department of Energy .3 Million to Identify Renewable Energy Zones in Western States DOE to Invest up to $2.3 Million to Identify Renewable Energy Zones in Western States May 28, 2008 - 12:32pm Addthis The Renewable Energy Zones Initiative will promote regional transmission planning and encourage the development of renewable sources of energy WASHINGTON, DC - U.S. Department of Energy (DOE) Assistant Secretary for Electricity Delivery and Energy Reliability Kevin Kolevar

  13. The Viability of Sustainable, Self-Propping Shear Zones in Ehanced

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Geothermal Systems: Measurement of Reaction Rates at Elevated Temperatures | Department of Energy The Viability of Sustainable, Self-Propping Shear Zones in Ehanced Geothermal Systems: Measurement of Reaction Rates at Elevated Temperatures The Viability of Sustainable, Self-Propping Shear Zones in Ehanced Geothermal Systems: Measurement of Reaction Rates at Elevated Temperatures The Viability of Sustainable, Self-Propping Shear Zones in Ehanced Geothermal Systems: Measurement of Reaction

  14. RELAP-7 Beta Release: Summary of Capabilities

    SciTech Connect (OSTI)

    Martineau, Richard C.; Zhang, Hongbin; Zhao, Haihua

    2014-12-01

    RELAP-7 is a nuclear systems safety analysis code being developed at the Idaho National Laboratory (INL). Building upon the decades of software development at the INL, we began the development of RELAP-7 in 2011 to support the Risk Informed Safety Margins Characterization (RISMC) Pathway. As part of this development, the first lines of RELAP-7 code were committed to the software revision control repository on November 7th, 2011. The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in computer architecture, software design, numerical methods, and physical models in order to provide capabilities needed for the RISMC methodology and to support nuclear power safety analysis. RELAP-7 is built using the INL’s modern scientific software development framework, MOOSE (Multi-physics Object Oriented Simulation Environment). MOOSE provides improved numerical calculations (including higher-order integration in both space and time, yielding converged second-order accuracy). The RELAP-7 code structure is based on multiple physical component models such as pipes, junctions, pumps, etc. Each component can have options for different fluid models such as single- and two-phase flow. This component-based and physics-based software architecture allows RELAP-7 to adopt different physical models for different applications. A relatively new two-phase hydrodynamic model, termed the ''7-Equation model'' for two phasic pressures, velocities, energies, and volumetric fraction, is incorporated into RELAP-7 for liquid-gas (water-steam) flows. This new model allows second-order integration because it is well-posed, which will reduce the numerical error associated with traditional systems analysis codes. In this paper, we provide a RELAP-7 capability list describing analysis features, range of applicability, and reactor components that will be available for the December 15th, 2014 beta release of the software.

  15. Time-of-flight radio location system

    DOE Patents [OSTI]

    McEwan, T.E.

    1996-04-23

    A bi-static radar configuration measures the direct time-of-flight of a transmitted RF pulse and is capable of measuring this time-of-flight with a jitter on the order of about one pico-second, or about 0.01 inch of free space distance for an electromagnetic pulse over a range of about one to ten feet. A transmitter transmits a sequence of electromagnetic pulses in response to a transmit timing signal, and a receiver samples the sequence of electromagnetic pulses with controlled timing in response to a receive timing signal, and generates a sample signal in response to the samples. A timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the sequence of electromagnetic pulses such that the time between transmission of pulses in the sequence and sampling by the receiver sweeps over a range of delays. The receive timing signal sweeps over the range of delays in a sweep cycle such that pulses in the sequence are sampled at the pulse repetition rate, and with different delays in the range of delays to produce a sample signal representing magnitude of a received pulse in equivalent time. Automatic gain control circuitry in the receiver controls the magnitude of the equivalent time sample signal. A signal processor analyzes the sample signal to indicate the time-of-flight of the electromagnetic pulses in the sequence. 7 figs.

  16. Carbon Dioxide Emissions From Vegetation-Kill Zones Around The...

    Open Energy Info (EERE)

    from locations west and east of the plant revealed the presence of isobutane related to plant operations. The 13C values of diffuse CO2 range from - 5.7 to - 3.4, similar...

  17. Alteration And Geochemical Zoning In Bodie Bluff, Bodie Mining...

    Open Energy Info (EERE)

    Banded, epithermal quartz-adularia veins have produced about 1.5 million ounces of gold and 7 million ounces of silver from the Bodie mining district, eastern California. The...

  18. Project Reach Completes Photographic Work in Room 7, Panel 7

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    February 5, 2015 Project Reach Completes Photographic Work in Room 7, Panel 7 Photographic work in support of the Accident Investigation Board (AIB) has been completed in Room 7...

  19. A Catalog of Vadose Zone Hydraulic Properties for the Hanford Site

    SciTech Connect (OSTI)

    Freeman, Eugene J.; Khaleel, Raziuddin; Heller, Paula R.

    2001-09-24

    The purpose of this catalog is to integrate all available soil physics data and information from vadose zone characterization and performance assessments into one useable, scientifically defensible document.

  20. The Viability of Sustainable, Self-Propping Shear Zones in Ehanced...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Viability of Sustainable, Self-Propping Shear Zones in Ehanced Geothermal Systems: Measurement of Reaction Rates at Elevated Temperatures The Viability of Sustainable,...

  1. Adams County, Iowa ASHRAE 169-2006 Climate Zone | Open Energy...

    Open Energy Info (EERE)

    Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Adams County, Iowa ASHRAE 169-2006 Climate Zone Jump to: navigation, search County Climate...

  2. Demonstration of 12 nm resolution Fresnel zone plate lens based soft x-ray microscopy

    SciTech Connect (OSTI)

    Chao, W.; Kim, J.; Rekawa, S.; Fischer, P.; Anderson, E. H.

    2009-06-05

    To extend soft x-ray microscopy to a resolution of order 10 nm or better, we developed a new nanofabrication process for Fresnel zone plate lenses. The new process, based on the double patterning technique, has enabled us to fabricate high quality gold zone plates with 12 nm outer zones. Testing of the zone plate with the full-field transmission x-ray microscope, XM-1, in Berkeley, showed that the lens clearly resolved 12 nm lines and spaces. This result represents a significant step towards 10 nm resolution and beyond.

  3. Gradient zone-boundary control in salt-gradient solar ponds

    DOE Patents [OSTI]

    Hull, J.R.

    1982-09-29

    A method and apparatus for suppressing zone boundary migration in a salt gradient solar pond includes extending perforated membranes across the pond at the boundaries, between the convective and non-convective zones, the perforations being small enough in size to prevent individual turbulence disturbances from penetrating the hole, but being large enough to allow easy molecular diffusion of salt thereby preventing the formation of convective zones in the gradient layer. The total area of the perforations is a sizeable fraction of the membrane area to allow sufficient salt diffusion while preventing turbulent entrainment into the gradient zone.

  4. DOE to Invest up to $2.3 Million to Identify Renewable Energy Zones In

    Office of Environmental Management (EM)

    Western States, May 28, 2008 | Department of Energy to Invest up to $2.3 Million to Identify Renewable Energy Zones In Western States, May 28, 2008 DOE to Invest up to $2.3 Million to Identify Renewable Energy Zones In Western States, May 28, 2008 DOE to Invest up to $2.3 Million to Identify Renewable Energy Zones In Western States. The Renewable Energy Zones Initiative will promote regional transmission planning and encourage the development of renewable sources of energy. PDF icon DOE to

  5. 7Be General Tables

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Be General Table The General Table for 7Be is subdivided into the following categories: Reviews Experimental Work Shell Model Cluster Model Other Theoretical Work Model Calculations Projectile Fragmentation and Multifragmentation Astrophysical b Decay Astrophysical Neutrinos Hypernuclei, Mesons and Other Exotic Particles Applications

  6. FY 2005 Volume 7

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    8 Volume 7 Interior & Related Agencies Interior & Related Agencies Fossil Energy Research & Development Fossil Energy Research & Development Naval Petroleum & Oil Shale Reserves Naval Petroleum & Oil Shale Reserves Elk Hills School Lands Fund Elk Hills School Lands Fund Energy Conservation Energy Conservation Economic Regulation Economic Regulation Strategic Petroleum Reserve Strategic Petroleum Reserve Energy Information Administration Energy Information Administration

  7. Precision timing measurements for high energy photons

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Anderson, Dustin; Apreysan, Artur; Bornheim, Adi; Duarte, Javier; Newman, Harvey; Pena, Cristian; Ronzhin, Anatoly; Spiropulu, Maria; Trevor, Jason; Xie, Si; et al

    2014-11-21

    Particle colliders operating at high luminosities present challenging environments for high energy physics event reconstruction and analysis. We discuss how timing information, with a precision on the order of 10 ps, can aid in the reconstruction of physics events under such conditions. We present calorimeter based timing measurements from test beam experiments in which we explore the ultimate timing precision achievable for high energy photons or electrons of 10 GeV and above. Using a prototype calorimeter consisting of a 1.7Ś1.7Ś1.7 cm3 lutetium–yttrium oxyortho-silicate (LYSO) crystal cube, read out by micro-channel plate photomultipliers, we demonstrate a time resolution of 33.5±2.1 psmore »for an incoming beam energy of 32 GeV. In a second measurement, using a 2.5Ś2.5Ś20 cm3 LYSO crystal placed perpendicularly to the electron beam, we achieve a time resolution of 59±11 ps using a beam energy of 4 GeV. We also present timing measurements made using a shashlik-style calorimeter cell made of LYSO and tungsten plates, and demonstrate that the apparatus achieves a time resolution of 54±5 ps for an incoming beam energy of 32 GeV.« less

  8. Summary of Uranium Solubility Studies in Concrete Waste Forms and Vadose Zone Environments

    SciTech Connect (OSTI)

    Golovich, Elizabeth C.; Wellman, Dawn M.; Serne, R. Jeffrey; Bovaird, Chase C.

    2011-09-30

    One of the methods being considered for safely disposing of Category 3 low-level radioactive wastes is to encase the waste in concrete. Concrete encasement would contain and isolate the waste packages from the hydrologic environment and act as an intrusion barrier. The current plan for waste isolation consists of stacking low-level waste packages on a trench floor, surrounding the stacks with reinforced steel, and encasing these packages in concrete. These concrete-encased waste stacks are expected to vary in size with maximum dimensions of 6.4 m long, 2.7 m wide, and 4 m high. The waste stacks are expected to have a surrounding minimum thickness of 15 cm of concrete encasement. These concrete-encased waste packages are expected to withstand environmental exposure (solar radiation, temperature variations, and precipitation) until an interim soil cover or permanent closure cover is installed and to remain largely intact thereafter. Any failure of concrete encasement may result in water intrusion and consequent mobilization of radionuclides from the waste packages. This report presents the results of investigations elucidating the uranium mineral phases controlling the long-term fate of uranium within concrete waste forms and the solubility of these phases in concrete pore waters and alkaline, circum-neutral vadose zone environments.

  9. Short residence time coal liquefaction process including catalytic hydrogenation

    DOE Patents [OSTI]

    Anderson, R.P.; Schmalzer, D.K.; Wright, C.H.

    1982-05-18

    Normally solid dissolved coal product and a distillate liquid product are produced by continuously passing a feed slurry comprising raw feed coal and a recycle solvent oil and/or slurry together with hydrogen to a preheating-reaction zone, the hydrogen pressure in the preheating-reaction zone being at least 1,500 psig (105 kg/cm[sup 2]), reacting the slurry in the preheating-reaction zone at a temperature in the range of between about 455 and about 500 C to dissolve the coal to form normally liquid coal and normally solid dissolved coal. A total slurry residence time is maintained in the reaction zone ranging from a finite value from about 0 to about 0.2 hour, and reaction effluent is continuously and directly contacted with a quenching fluid to substantially immediately reduce the temperature of the reaction effluent to below 425 C to substantially inhibit polymerization so that the yield of insoluble organic matter comprises less than 9 weight percent of said feed coal on a moisture-free basis. The reaction is performed under conditions of temperature, hydrogen pressure and residence time such that the quantity of distillate liquid boiling within the range C[sub 5]-454 C is an amount at least equal to that obtainable by performing the process under the same condition except for a longer total slurry residence time, e.g., 0.3 hour. Solvent boiling range liquid is separated from the reaction effluent and recycled as process solvent. The amount of solvent boiling range liquid is sufficient to provide at least 80 weight percent of that required to maintain the process in overall solvent balance. 6 figs.

  10. Short residence time coal liquefaction process including catalytic hydrogenation

    DOE Patents [OSTI]

    Anderson, Raymond P. (Overland Park, KS); Schmalzer, David K. (Englewood, CO); Wright, Charles H. (Overland Park, KS)

    1982-05-18

    Normally solid dissolved coal product and a distillate liquid product are produced by continuously passing a feed slurry comprising raw feed coal and a recycle solvent oil and/or slurry together with hydrogen to a preheating-reaction zone (26, alone, or 26 together with 42), the hydrogen pressure in the preheating-reaction zone being at least 1500 psig (105 kg/cm.sup.2), reacting the slurry in the preheating-reaction zone (26, or 26 with 42) at a temperature in the range of between about 455.degree. and about 500.degree. C. to dissolve the coal to form normally liquid coal and normally solid dissolved coal. A total slurry residence time is maintained in the reaction zone ranging from a finite value from about 0 to about 0.2 hour, and reaction effluent is continuously and directly contacted with a quenching fluid (40, 68) to substantially immediately reduce the temperature of the reaction effluent to below 425.degree. C. to substantially inhibit polymerization so that the yield of insoluble organic matter comprises less than 9 weight percent of said feed coal on a moisture-free basis. The reaction is performed under conditions of temperature, hydrogen pressure and residence time such that the quantity of distillate liquid boiling within the range C.sub.5 -454.degree. C. is an amount at least equal to that obtainable by performing the process under the same condition except for a longer total slurry residence time, e.g., 0.3 hour. Solvent boiling range liquid is separated from the reaction effluent (83) and recycled as process solvent (16). The amount of solvent boiling range liquid is sufficient to provide at least 80 weight percent of that required to maintain the process in overall solvent balance.

  11. NUG Webinar Nov. 7, 2013

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7, 2013 NUG Webinar Nov. 7, 2013 November 7, 2013 Remote Connection Info https:nersc-training.webex.com Attendance: 23 Agenda Edison Update NUG 2014 Annual Usage Group Meeting...

  12. TIME-LAPSE SEISMIC MODELING & INVERSION OF CO2 SATURATION FOR SEQUESTRATION AND ENHANCED OIL RECOVERY

    SciTech Connect (OSTI)

    Mark A. Meadows

    2006-03-31

    Injection of carbon dioxide (CO2) into subsurface aquifers for geologic storage/sequestration, and into subsurface hydrocarbon reservoirs for enhanced oil recovery, has become an important topic to the nation because of growing concerns related to global warming and energy security. In this project we developed new ways to predict and quantify the effects of CO2 on seismic data recorded over porous reservoir/aquifer rock systems. This effort involved the research and development of new technology to: (1) Quantitatively model the rock physics effects of CO2 injection in porous saline and oil/brine reservoirs (both miscible and immiscible). (2) Quantitatively model the seismic response to CO2 injection (both miscible and immiscible) from well logs (1D). (3) Perform quantitative inversions of time-lapse 4D seismic data to estimate injected CO2 distributions within subsurface reservoirs and aquifers. This work has resulted in an improved ability to remotely monitor the injected CO2 for safe storage and enhanced hydrocarbon recovery, predict the effects of CO2 on time-lapse seismic data, and estimate injected CO2 saturation distributions in subsurface aquifers/reservoirs. We applied our inversion methodology to a 3D time-lapse seismic dataset from the Sleipner CO2 sequestration project, Norwegian North Sea. We measured changes in the seismic amplitude and traveltime at the top of the Sleipner sandstone reservoir and used these time-lapse seismic attributes in the inversion. Maps of CO2 thickness and its standard deviation were generated for the topmost layer. From this information, we estimated that 7.4% of the total CO2 injected over a five-year period had reached the top of the reservoir. This inversion approach could also be applied to the remaining levels within the anomalous zone to obtain an estimate of the total CO2 injected.

  13. Summary of Vadose -- Zone Conceptual Models for Flow and Contaminant Transport and 1999 - 2003 Progress on Resolving Deficiencies in Understanding the Vadose Zone at the INEEL

    SciTech Connect (OSTI)

    Robert C. Starr; Dana L. Dettmers; Brennon R. Orr; Thomas R. Wood

    2003-12-01

    The thick vadose zone that underlies the Idaho National Engineering and Environmental Laboratory has been recognized both as an avenue through which contaminants disposed at or near the ground surface can migrate to groundwater in the underlying Eastern Snake River Plain aquifer, and as a barrier to the movement of contaminants into the aquifer. Flow and contaminant transport in the vadose zone at the INEEL is complicated by the highly heterogeneous nature of the geologic framework and by the variations in the behavior of different contaminants in the subsurface. The state of knowledge concerning flow and contaminant transport in the vadose zone at and near the INEEL IN 1999 was summarized in Deficiencies in Vadose Zone Understanding at the Idaho National Engineering and Environmental Laboratory (Wood et al., 2000). These authors identified deficiencies in knowledge of flow and contaminant transport processes in the vadose zone, and provided recommendations for additional work that should be conducted to address these deficiencies. In the period since (Wood et al., 2000) was prepared, research has been published that, to some degree, address these deficiencies. This document provides a bibliography of reports, journal articles, and conference proceedings published 1999 through mid-2003 that are relevant to the vadose zone at or near the INEEL and provides a brief description of each work. Publications that address specific deficiencies or recommendations are identified, and pertinent information from selected publications is presented.

  14. Part 7 of 11

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    , E, The Subcontractor shall include the substance of this clause, including this paragraph (E), in each lower-tier subcontract or purchase under this subcontract that may involve international air transportation, * CLAUSE 36 - TERMINATION FOR CONVENIENCE OF NREL/GOVERNMENT (EDUCATIONAL AND OTHER NONPROFIT INSTITUTIONS) (SEP 1996) Derivedfrom FAR 52.249-5 (FD) A. NREL may terminate performance of work under thi s subcontract in whole or, from time to time, in part if the NREL Subcontract

  15. Means and method for capillary zone electrophoresis with laser-induced indirect fluorescence detection

    DOE Patents [OSTI]

    Yeung, Edward S. (Ames, IA); Kuhr, Werner G. (Riverside, CA)

    1996-02-20

    A means and method for capillary zone electrphoresis with laser-induced indirect fluorescence detection. A detector is positioned on the capillary tube of a capillary zone electrophoresis system. The detector includes a laser which generates a laser beam which is imposed upon a small portion of the capillary tube. Fluorescence of the elutant electromigrating through the capillary tube is indirectly detected and recorded.

  16. Means and method for capillary zone electrophoresis with laser-induced indirect fluorescence detection

    DOE Patents [OSTI]

    Yeung, Edwards (Ames, IA); Kuhr, Werner G. (Riverside, CA)

    1991-04-09

    A means and method for capillary zone electrphoresis with laser-induced indirect fluorescence detection. A detector is positioned on the capillary tube of a capillary zone electrophoresis system. The detector includes a laser which generates a laser beam which is imposed upon a small portion of the capillary tube. Fluorescence of the elutant electromigrating through the capillary tube is indirectly detected and recorded.

  17. Potential effects of low-volume effluent discharges on past-practice vadose zone contamination

    SciTech Connect (OSTI)

    Barnett, D.B., Westinghouse Hanford

    1996-07-30

    Collard, L. B., J. D. Davis, D. B. Barnett, 1996, Potential Effects of Low-Volume Effluent Discharges on Past Practice Vadose Zone Contamination: WHC-SD-LEF-ER-001, Westinghouse Hanford Company, Richland Washington. This document estimates the behavior of extremely low-discharges of water in the unsaturated zone in the vicinity of past-practice facilities.

  18. Solid oxide fuel cell systems with hot zones having improved reactant distribution

    DOE Patents [OSTI]

    Poshusta, Joseph C.; Booten, Charles W.; Martin, Jerry L.

    2012-11-06

    A Solid Oxide Fuel Cell (SOFC) system having a hot zone with a center cathode air feed tube for improved reactant distribution, a CPOX reactor attached at the anode feed end of the hot zone with a tail gas combustor at the opposing end for more uniform heat distribution, and a counter-flow heat exchanger for efficient heat retention.

  19. Solid oxide fuel cell systems with hot zones having improved reactant distribution

    DOE Patents [OSTI]

    Poshusta, Joseph C; Booten, Charles W; Martin, Jerry L

    2013-12-24

    A Solid Oxide Fuel Cell (SOFC) system having a hot zone with a center cathode air feed tube for improved reactant distribution, a CPOX reactor attached at the anode feed end of the hot zone with a tail gas combustor at the opposing end for more uniform heat distribution, and a counter-flow heat exchanger for efficient heat retention.

  20. Trace-element zoning in garnets from sheared mantle xenoliths

    SciTech Connect (OSTI)

    Griffin, W.L.; Cousens, D.R.; Ryan, C.G.; Sie, S.H.; Suter, G.F. ); Smith, D. ); Boyd, F.R. )

    1989-02-01

    Proton-microprobe analyses of garnets from sheared high-temperature ultramafic xenoliths reveal marked zonation of trace elements, paralleling trends in major and minor elements. Garnet rims (600-1,000 {mu}m wide) are enriched in Fe, Ti, Zr, Y and Ga, and either enriched or depleted in Cr, relative to cores. Zoning profiles for Ti and Zr are S-shaped and extend further into the grains than the Cr and Ga gradients. The profiles are consistent with the formation of Ti, Zr, Y-enriched garnet overgrowths, followed by diffusive equilibration between rim and core over years to hundreds of years. This enrichment in Fe, Ca, Al and incompatible elements is ascribed to melt infiltration and consequent melt-crystal exchange and garnet growth, shortly before eruption. Zr/Y is 1 to 2 in garnet cores but 4 to 5 in rims, and so the infiltrating melt may have been relatively alkalic. Major and trace element concentrations in such high-temperature sheared xenoliths are not likely to resemble those of primitive mantle or of residual mantle depleted by melt extraction.

  1. Vadose Zone Hydrogeology Data Package for Hanford Assessments

    SciTech Connect (OSTI)

    Last, George V.; Freeman, Eugene J.; Cantrell, Kirk J.; Fayer, Michael J.; Gee, Glendon W.; Nichols, William E.; Bjornstad, Bruce N.; Horton, Duane G.

    2006-06-01

    This data package documents the technical basis for selecting physical and geochemical parameters and input values that will be used in vadose zone modeling for Hanford assessments. This work was originally conducted as part of the Characterization of Systems Task of the Groundwater Remediation Project managed by Fluor Hanford, Inc., Richland, Washington, and revised as part of the Characterization of Systems Project managed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy, Richland Operations Office (DOE-RL). This data package describes the geologic framework, the physical, hydrologic, and contaminant transport properties of the geologic materials, and deep drainage (i.e., recharge) estimates, and builds on the general framework developed for the initial assessment conducted using the System Assessment Capability (SAC) (Bryce et al. 2002). The general approach for this work was to update and provide incremental improvements over the previous SAC data package completed in 2001. As with the previous SAC data package, much of the data and interpreted information were extracted from existing documents and databases. Every attempt was made to provide traceability to the original source(s) of the data or interpretations.

  2. Task Time Tracker

    Energy Science and Technology Software Center (OSTI)

    2013-07-24

    This client-side web app tracks the amount of time spent on arbitrary tasks. It allosw the creation of an unlimited number of arbitrarily named tasks ans via simple interactions, tracks the amount of time spent working on the drfined tasks.

  3. Time varying voltage combustion control and diagnostics sensor

    DOE Patents [OSTI]

    Chorpening, Benjamin T. (Morgantown, WV); Thornton, Jimmy D. (Morgantown, WV); Huckaby, E. David (Morgantown, WV); Fincham, William (Fairmont, WV)

    2011-04-19

    A time-varying voltage is applied to an electrode, or a pair of electrodes, of a sensor installed in a fuel nozzle disposed adjacent the combustion zone of a continuous combustion system, such as of the gas turbine engine type. The time-varying voltage induces a time-varying current in the flame which is measured and used to determine flame capacitance using AC electrical circuit analysis. Flame capacitance is used to accurately determine the position of the flame from the sensor and the fuel/air ratio. The fuel and/or air flow rate (s) is/are then adjusted to provide reduced flame instability problems such as flashback, combustion dynamics and lean blowout, as well as reduced emissions. The time-varying voltage may be an alternating voltage and the time-varying current may be an alternating current.

  4. Digital time delay

    DOE Patents [OSTI]

    Martin, A.D.

    1986-05-09

    Method and apparatus are provided for generating an output pulse following a trigger pulse at a time delay interval preset with a resolution which is high relative to a low resolution available from supplied clock pulses. A first lumped constant delay provides a first output signal at predetermined interpolation intervals corresponding to the desired high resolution time interval. Latching circuits latch the high resolution data to form a first synchronizing data set. A selected time interval has been preset to internal counters and corrected for circuit propagation delay times having the same order of magnitude as the desired high resolution. Internal system clock pulses count down the counters to generate an internal pulse delayed by an internal which is functionally related to the preset time interval. A second LCD corrects the internal signal with the high resolution time delay. A second internal pulse is then applied to a third LCD to generate a second set of synchronizing data which is complementary with the first set of synchronizing data for presentation to logic circuits. The logic circuits further delay the internal output signal with the internal pulses. The final delayed output signal thereafter enables the output pulse generator to produce the desired output pulse at the preset time delay interval following input of the trigger pulse.

  5. Parallel time integration software

    Energy Science and Technology Software Center (OSTI)

    2014-07-01

    This package implements an optimal-scaling multigrid solver for the (non) linear systems that arise from the discretization of problems with evolutionary behavior. Typically, solution algorithms for evolution equations are based on a time-marching approach, solving sequentially for one time step after the other. Parallelism in these traditional time-integrarion techniques is limited to spatial parallelism. However, current trends in computer architectures are leading twards system with more, but not faster. processors. Therefore, faster compute speeds mustmore » come from greater parallelism. One approach to achieve parallelism in time is with multigrid, but extending classical multigrid methods for elliptic poerators to this setting is a significant achievement. In this software, we implement a non-intrusive, optimal-scaling time-parallel method based on multigrid reduction techniques. The examples in the package demonstrate optimality of our multigrid-reduction-in-time algorithm (MGRIT) for solving a variety of parabolic equations in two and three sparial dimensions. These examples can also be used to show that MGRIT can achieve significant speedup in comparison to sequential time marching on modern architectures.« less

  6. Appendix B-7

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 STANDARD TERMS AND CONDITIONS FOR (1) CONSULTANTS, AND (2) TECHNICAL SERVICES (Where Service Contract Act Does Not Apply) JULY 11, 2014 Subcontractor is hereby on notice that the contracting party to this subcontract is the Alliance for Sustainable Energy, LLC, in its capacity as the Managing and Operating Contractor for the National Renewable Energy Laboratory (NREL) under U.S. Department No. DE-AC36-08GO28308. All references to "NREL" in this subcontract shall mean the Alliance for

  7. Word Pro - S7

    Gasoline and Diesel Fuel Update (EIA)

    21 Table 7.5 Stocks of Coal and Petroleum: Electric Power Sector Coal a Petroleum Distillate Fuel Oil b Residual Fuel Oil c Other Liquids d Petroleum Coke e Total e,f Thousand Short Tons Thousand Barrels Thousand Short Tons Thousand Barrels 1950 Year ............................. 31,842 NA NA NA NA 10,201 1955 Year ............................. 41,391 NA NA NA NA 13,671 1960 Year ............................. 51,735 NA NA NA NA 19,572 1965 Year ............................. 54,525 NA NA NA NA

  8. Word Pro - S7

    Gasoline and Diesel Fuel Update (EIA)

    23 Table 7.6 Electricity End Use (Million Kilowatthours) Retail Sales a Direct Use f Total End Use g Discontinued Retail Sales Series Residential Commercial b Industrial c Transpor- tation d Total Retail Sales e Commercial (Old) h Other (Old) i 1950 Total .................... 72,200 E 65,971 146,479 E 6,793 291,443 NA 291,443 50,637 22,127 1955 Total .................... 128,401 E 102,547 259,974 E 5,826 496,748 NA 496,748 79,389 28,984 1960 Total .................... 201,463 E 159,144 324,402 E

  9. set7.pdf

    U.S. Energy Information Administration (EIA) Indexed Site

    Heat Pumps Furnaces Individual Space Heaters District Heat Boilers Packaged Heating Units Other All Buildings ............................................... 67,338 61,602 8,923 14,449 17,349 5,534 19,522 25,743 4,073 Building Floorspace (Square Feet) 1,001 to 5,000 .............................................. 6,774 5,684 679 2,271 1,183 Q 463 1,779 250 5,001 to 10,000 ............................................ 8,238 7,090 745 2,848 1,350 Q 1,040 2,301 Q 10,001 to 25,000

  10. VARIABLE TIME DELAY MEANS

    DOE Patents [OSTI]

    Clemensen, R.E.

    1959-11-01

    An electrically variable time delay line is described which may be readily controlled simuitaneously with variable impedance matching means coupied thereto such that reflections are prevented. Broadly, the delay line includes a signal winding about a magnetic core whose permeability is electrically variable. Inasmuch as the inductance of the line varies directly with the permeability, the time delay and characteristic impedance of the line both vary as the square root of the permeability. Consequently, impedance matching means may be varied similariy and simultaneously w:th the electrically variable permeability to match the line impedance over the entire range of time delay whereby reflections are prevented.

  11. Graduate Program Time Limits and Work Schedules

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Time Limits and Work Schedules Graduate Program Time Limits and Work Schedules Point your career towards Los Alamos Lab: work with the best minds on the planet in an inclusive environment that is rich in intellectual vitality and opportunities for growth. Contact Student Programs (505) 665-0987 Email Time Limits The length of participation in the graduate program is limited as follows: With a bachelor's pursuing a master's degree: 4 years With a bachelor's pursuing a PhD: 7 years With a master's

  12. Drug Retention Times

    SciTech Connect (OSTI)

    Center for Human Reliability Studies

    2007-05-01

    The purpose of this monograph is to provide information on drug retention times in the human body. The information provided is based on plausible illegal drug use activities that might be engaged in by a recreational drug user.

  13. Drug Retention Times

    SciTech Connect (OSTI)

    Center for Human Reliability Studies

    2007-05-01

    The purpose of this monograph is to provide information on drug retention times in the human body. The information provided is based on plausible illegal drug use activities that might be engaged in by a recreational drug user

  14. Time-Resolved

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Ultrafast Spectroscopy of Warm Dense Matter Real-Time Chemical Imaging of Bacterial Biofilm Development Using Light to Control How X Rays Interact with Matter X-Ray Imaging of...

  15. Hydrogeologic characterization of an arid zone Radioactive Waste Management Site

    SciTech Connect (OSTI)

    Ginanni, J.M.; O`Neill, L.J. [USDOE Nevada Operations Office, Las Vegas, NV (United States); Hammermeister, D.P.; Blout, D.O.; Dozier, B.L.; Sully, M.J.; Johnejack, K.R.; Emer, D.F. [Reynolds Electrical and Engineering Co., Inc., Las Vegas, NV (United States); Tyler, S.W. [Nevada Univ., Reno, NV (United States). Desert Research Inst.

    1994-06-01

    An in-depth subsurface site characterization and monitoring program for the soil water migration pathway has been planned, implemented, and completed to satisfy data requirements for a waiver from groundwater monitoring, for an exemption from liner leachate collections systems, and for different regulatory driven performance assessments. A traditional scientific approach has been taken to focus characterization and monitoring efforts. This involved developing a conceptual model of the hydrogeologic system and defining and testing hypotheses about this model. Specific hypotheses tested included: that the system was hydrologically heterogenous and anisotropic, and that recharge was very low or negligible. Mineralogical, physical, and hydrologic data collected to test hypotheses has shown the hydrologic system to be remarkably homogenous and isotropic rather than heterogenous and anisotropic. Both hydrodynamic and environmental tracer approaches for estimating recharge have led to the conclusion that recharge from the Area 5 RWMS is not occurring in the upper region of the vadose zone, and that recharge at depth is extremely small or negligible. This demonstration of ``no migration of hazardous constituents to the water table satisfies a key requirement for both the groundwater monitoring waiver and the exemption from liner leachate collection systems. Data obtained from testing hypotheses concerning the soil water migration pathway have been used to refine the conceptual model of the hydrogeologic system of the site. These data suggest that the soil gas and atmospheric air pathways may be more important for transporting contaminants to the accessible environment than the soil water pathway. New hypotheses have been developed about these pathways, and characterization and monitoring activities designed to collect data to test these hypotheses.

  16. Time Card Entry System

    Energy Science and Technology Software Center (OSTI)

    1996-05-07

    The Time Card Entry System was developed for the Department of Enegy, Idaho Operations Office (DOE-ID) to interface with the DOE headquarters (DOE-HQ) Electronic Time and Attendance (ETA) system for payroll. It features pop-up window pick lists for Work Breakdown Structure numbers and Hour Codes and has extensive processing that ensures that time and attendance reported by the employee fulfills U.S. Government/OMB requirements before Timekeepers process the data at the end of the two weekmore » payroll cycle using ETA. A tour of duty profile (e.g., ten hour day, four day week with Sunday, friday and Saturday off), previously established in the ETA system, is imported into the Time Card Entry System by the timekeepers. An individual''s profile establishes the basis for validation of time of day and number of hours worked per day. At the end of the two cycle, data is exported by the timekeepers from the Time Card Entry System into ETA files.« less

  17. A Markov chain analysis of fish movements to determine entrainment zones

    SciTech Connect (OSTI)

    Johnson, Gary E.; Hedgepeth, J.; Skalski, John R.; Giorgi, Albert E.

    2004-06-01

    The extent of the biological zone of influence (BZI) of a water withdrawal port, such as a cooling water intake or a smolt bypass, directly reflects its local effect on fish. This study produced a new technique to determine the BZI, defined as the region immediately upstream of a portal where the probability of fish movement toward the portal is greater than 90%. We developed and applied the technique at The Dalles Dam on the Columbia River, where the ice/trash sluiceway functions as a surface flow smolt bypass. To map the BZI, we applied a Markov-Chain analysis to smolt movement data collected with an active fish tracking sonar system. Probabilities of fish movement from cell to cell in the sample volume, calculated from tracked fish data, formed a Markov transition matrix. Multiplying this matrix by itself many times with absorption at the boundaries produced estimates of probability of passage out each side of the sample volume from the cells within. The BZI of a sluiceway entrance at The Dalles Dam was approximately 5 m across and extended 6-8 m out from the face of the dam in the surface layer 2-3 m deep. BZI mapping is applicable to many bioengineering efforts to protect fish populations.

  18. Development Of Regional Climate Mitigation Baseline For A DominantAgro-Ecological Zone Of Karnataka, India

    SciTech Connect (OSTI)

    Sudha, P.; Shubhashree, D.; Khan, H.; Hedge, G.T.; Murthy, I.K.; Shreedhara, V.; Ravindranath, N.H.

    2007-06-01

    Setting a baseline for carbon stock changes in forest andland use sector mitigation projects is an essential step for assessingadditionality of the project. There are two approaches for settingbaselines namely, project-specific and regional baseline. This paperpresents the methodology adopted for estimating the land available formitigation, for developing a regional baseline, transaction cost involvedand a comparison of project-specific and regional baseline. The studyshowed that it is possible to estimate the potential land and itssuitability for afforestation and reforestation mitigation projects,using existing maps and data, in the dry zone of Karnataka, southernIndia. The study adopted a three-step approach for developing a regionalbaseline, namely: i) identification of likely baseline options for landuse, ii) estimation of baseline rates of land-use change, and iii)quantification of baseline carbon profile over time. The analysis showedthat carbon stock estimates made for wastelands and fallow lands forproject-specific as well as the regional baseline are comparable. Theratio of wasteland Carbon stocks of a project to regional baseline is1.02, and that of fallow lands in the project to regional baseline is0.97. The cost of conducting field studies for determination of regionalbaseline is about a quarter of the cost of developing a project-specificbaseline on a per hectare basis. The study has shown the reliability,feasibility and cost-effectiveness of adopting regional baseline forforestry sectormitigation projects.

  19. UNSATURATED ZONE CALCITE 813C EVIDENCE OF SOUTHERN NEVADA CLIMATES DURING THE PAST 9 MILLION YEARS

    SciTech Connect (OSTI)

    JOSEPH F. WHELAN AND RICHARD J. MOSCATI

    1998-01-26

    Yucca Mountain, Nevada, is presently the object of intense study as a potential permanent repository for the Nation's high-level radioactive wastes. The mountain consists of a thick sequence of volcanic tuffs in which the depth to the water table ranges from 500 to 700 meters below the land surface. This thick unsaturated zone (UZ), which would host the projected repository, coupled with the present-day arid to semi-arid environment, is considered a positive argument for the site. Evaluation of the site includes defining the relationship between climate variability, as the input function or driver of site- and regional-scale ground-water flow, and the possible transport and release of radionuclides. Secondary calcite and opal have been deposited in the UZ by meteoric waters that infiltrated through overlying soils and percolated through the tuffs. The oxygen isotopic composition ({delta}{sup 18}O values) of these minerals reflect contemporaneous meteoric waters and the {delta}{sup 13}C values reflect soil organic matter, and hence the resident plant community, at the time of infiltration (Whelan et al., 1994). Recent U/Pb age determinations of opal in these occurrences allows the {delta}{sup 13}C values of associated calcite to be used to reconstruct general climate variations during the past 9 M.y.

  20. Technical and Policy Challenges in Deep Vadose Zone Remediation of Metals and Radionuclides - 12025

    SciTech Connect (OSTI)

    Wellman, Dawn M.; Truex, Michael J.; Freshley, Mark; Cantrell, Kirk J.; Dresel, P. Evan

    2012-07-01

    Deep vadose zone contamination is a significant issue facing the U.S. Department of Energy's (DOE) Office of Environmental Management (EM). Contamination in the deep vadose zone is isolated from exposure such that direct contact is not a factor in risk to human health and the environment. Transport of deep vadose zone contamination and discharge to the groundwater creates the potential for exposure and risk to receptors, so limiting flux to groundwater is key for protection of groundwater resources. Remediation approaches for the deep vadose zone need to be considered within the regulatory context, targeted at mitigating the source of contamination and reducing contaminant flux to groundwater. Processes for deep vadose zone metal and radionuclide remediation are discussed, as well as challenges and opportunities for implementation. It may be useful to consider the risk and challenges with leaving contaminants in place as part of a flux-control remedy in comparison with risks associated with contaminant removal and final disposition elsewhere. Understanding and quantifying the ramifications of contaminant removal and disposition options are therefore warranted. While this review suggests that some additional development work is needed for deep vadose zone remediation techniques, the benefits of applying vadose zone remediation for groundwater protection are compelling and worthy of continued development. (authors)

  1. Excitation functions of {sup 6,7}Li+{sup 7}Li reactions at low energies

    SciTech Connect (OSTI)

    Prepolec, L.; Soic, N.; Blagus, S.; Miljanic, D.; Siketic, Z.; Skukan, N.; Uroic, M.; Milin, M.

    2009-08-26

    Differential cross sections of {sup 6,7}Li+{sup 7}Li nuclear reactions have been measured at forward angles (10 deg. and 20 deg.), using particle identification detector telescopes, over the energy range 2.75-10.00 MeV. Excitation functions have been obtained for low-lying residual-nucleus states. The well pronounced peak in the excitation function of {sup 7}Li({sup 7}Li,{sup 4}He){sup 10}Be(3.37 MeV,2{sup +}) at beam energy about 8 MeV, first observed by Wyborny and Carlson in 1971 at 0 deg., has been observed at 10 deg., but is less evident at 20 deg. The cross section obtained for the {sup 7}Li({sup 7}Li,{sup 4}He){sup 10}Be(g.s,0{sup +}) reaction is about ten times smaller. The well pronounced peak in the excitation function of {sup 7}Li({sup 7}Li,{sup 4}He){sup 10}Be(3.37 MeV,2{sup +}) reaction could correspond to excited states in {sup 14}C, at excitation energies around 30 MeV.

  2. L-7 J

    Office of Legacy Management (LM)

    t *G.E; ?$UCLEONICS PROJECT r\ _- P s .- f t-h -_ r* 4 -_ :. i > \ ,' *< I 2 ;.:. - ' - - . i .;, L-7 J ti * _._ -4. _ - s. e_ ,.. -a,: -+ G ,' -x ' * .- I" g ;"_ Clrssification Cancaltd GJ5N l#AJAw.&* 1 \ : #XC J d.?;*c / fi,2,3,4 - F.C. S-chl-er, 1 Richla' nd, Washington ?ecember 15, 1948 By Authod&f u.....-... e -..I. :.,,..e u. 5. aomic J3.m~ coJnraission HanfomNper&ionOXfice ; Rich'frurd, u- A+tiion* ar, P; Ci S&m&, Panag;er - :, I, '/ ." .I: ., .; ~

  3. Notice of Construction for Tank Waste Remediation System Vadose Zone Characterization

    SciTech Connect (OSTI)

    HILL, J.S.

    2000-03-08

    The following description and any attachments and references are provided to the Washington State Department of Health (WDOH), Division of Radiation Protection, Air Emissions & Defense Waste Section as a notice of construction (NOC) in accordance with Washington Administrative Code (WAC) 246-247, Radiation Protection--Air Emissions. The WAC 246-247-060, ''Applications, registration, and licensing'', states ''This section describes the information requirements for approval to construct, modify, and operate an emission unit. Any NOC requires the submittal of information listed in Appendix A,'' Appendix A (WAC 246-247-1 10) lists the requirements that must be addressed. The original NOC was submitted in May of 1999 as DOE/TU-99-34. Additionally, the following description, attachments and references are provided to the U.S. Environmental Protection Agency (EPA) as an NOC, in accordance with Title 40 Code of Federal Regulations (CFR), Part 61, ''National Emission Standards for Hazardous Air Pollutants.'' The information required for submittal to the EPA is specified in 40 CFR 61.07. The potential emissions from this activity are estimated to provide less than 0.1 millirem/year total effective dose equivalent (TEDE) to the hypothetical offsite maximally exposed individual (MEI), and commencement is needed within a short time frame. Therefore, this application is also intended to provide notification of the anticipated date of initial startup in accordance with the requirement listed in 40 CFR 61.09(axl), and it is requested that approval of this application will also constitute EPA acceptance of this initial start-up notification. Written notification of the actual date of initial startup, in accordance with the requirement listed in 40 CFR 61.09(a)(2) will be provided at a later date. This NOC covers the activities associated with vadose zone characterization within the Single-Shell Tank Farms located in the 200-East and 200-West Areas of the Hanford Site. Vadose zone characterization activities include the drilling and sampling of soil from the surface to the depth of groundwater. Boreholes that are drilled to groundwater will be extended into the aquifer a sufficient distance to enable a groundwater sample to be collected. Under extenuating circumstances it may be prudent to complete these characterization boreholes as groundwater monitoring wells.

  4. Notice of Construction for Tank Waste Remediation System Vadose Zone Characterization

    SciTech Connect (OSTI)

    HILL, J.S.

    2000-04-20

    The following description and any attachments and references are provided to the Washington State Department of Health (WDOH), Division of Radiation Protection, Air Emissions and Defense Waste Section as a notice of construction (NOC) in accordance with Washington Administrative Code (WAC) 246-247, Radiation Protection-Air Emissions. The WAC 246-247-060, ''Applications, registration, and licensing'', states ''This section describes the information requirements for approval to construct, modify, and operate an emission unit. Any NOC requires the submittal of information listed in Appendix A.'' Appendix A (WAC 246-247-1 10) lists the requirements that must be addressed. The original NOC was submitted in May of 1999 as DOm-99-34. Additionally, the following description, attachments and references are provided to the U.S. Environmental Protection Agency (EPA) as an NOC, in accordance with Title 40 Code of Federal Regulations (CFR), Part 61, ''National Emission Standards for Hazardous Air Pollutants.'' The information required for submittal to the EPA is specified in 40 CFR 61.07. The potential emissions from this activity are estimated to provide less than 0.1 milliredyear total effective dose equivalent (TEDE) to the hypothetical offsite maximally exposed individual (MEI), and commencement is needed within a short time frame. Therefore, this application is also intended to provide notification of the anticipated date of initial start-up in accordance with the requirement listed in 40 CFR 61.09(a)(1), and it is requested that approval of this application will also constitute EPA acceptance of this initial start-up notification. Written notification of the actual date of initial startup, in accordance with the requirement listed in 40 CFR 61.09(a)(2) will be provided at a later date. This NOC covers the activities associated with vadose zone characterization within the Single-Shell Tank Farms located in the 200-East and 200-West Areas of the Hanford Site. Vadose zone characterization activities include the drilling and sampling of soil from the surface to the depth of groundwater. Boreholes that are drilled to groundwater will be extended into the aquifer a sufficient distance to enable a groundwater sample to be collected. Under extenuating circumstances it may be prudent to complete these characterization boreholes as groundwater monitoring wells.

  5. Geologic Assessment of the Damage Zone from the Second Test at Source Physics Experiment-Nevada (SPE-N)

    SciTech Connect (OSTI)

    Townsend, M. J.; Huckins-Gang, H. E.; Prothro, L. B.; Reed, D. N.

    2012-12-01

    The National Center for Nuclear Security, established by the U.S. Department of Energy, National Nuclear Security Administration (NNSA), is conducting a series of explosive tests at the Nevada National Security Site that are designed to increase the understanding of certain basic physical phenomena associated with underground explosions. These tests will aid in developing technologies that might be used to detect underground nuclear explosions in support of verification activities for the Comprehensive Nuclear-Test-Ban Treaty. The initial project is a series of explosive tests, known collectively as the Source Physics Experiment-Nevada (SPE-N), being conducted in granitic rocks. The SPE-N test series is designed to study the generation and propagation of seismic waves. The results will help advance the seismic monitoring capability of the United States by improving the predictive capability of physics-based modeling of explosive phenomena. The first SPE N (SPE-N-1) test was conducted in May 2011, using 100 kg of explosives at the depth of 54.9 m in the U 15n source hole. SPE-N-2 was conducted in October 2011, using 1,000 kg of explosives at the depth of 45.7 m in the same source hole. The SPE-N-3 test was conducted in the same source hole in July 2012, using the same amount and type of explosive as for SPE-N-2, and at the same depth as SPE-N-2, within the damage zone created by the SPE-N-2 explosion to investigate damage effects on seismic wave propagation. Following the SPE-N-2 shot and prior to the SPE-N-3 shot, the core hole U-15n#10 was drilled at an angle from the surface to intercept the SPE-N-2 shot point location to obtain information necessary to characterize the damage zone. The objective was to determine the position of the damage zone near the shot point, at least on the northeast, where the core hole penetrated it, and obtain information on the properties of the damaged medium. Geologic characterization of the post-SPE-N-2 core hole included geophysical logging, a directional survey, and geologic description of the core to document visual evidence of damage. Selected core samples were provided to Sandia National Laboratories (SNL) for measurement of physical and mechanical properties. A video was also run in the source hole after it was cleaned out. A significant natural fault zone was encountered in the angle core hole between 5.7 and 7.5 m from the shot point. However, several of the fractures observed in the core hole are interpreted as having been caused by the explosion. The fractures are characterized by a “fresh,” mechanically broken look, with uncoated and very irregular surfaces. They tend to terminate against natural fractures and have orientations that differ from the previously defined natural fracture sets; they are common starting at about 5.4 m from the shot point. Within about 3.3 m of the shot point to the end of the recovered core at 1.6 m from the shot point, some of the core samples are softer and lighter in color, but do not appear to be weathered. It is thought this could be indicative of the presence of distributed microfracturing.

  6. Microsoft PowerPoint - Central_Plateau_Inner_Zone.ppt [Compatibility Mode]

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Inner Zone The inner zone of the Central Plateau represents 10 square miles at the center The inner zone of the Central Plateau represents 10 square miles at the center of Hanford. Recovery Act funding will be used to accelerate construction of pump-and-treat systems to improve groundwater cleanup in the 200 West area. In addition funding will be used to prepare the Plutonium Finishing Plant for In addition funding will be used to prepare the Plutonium Finishing Plant for demolition and to tear

  7. Microsoft PowerPoint - Central_Plateau_Outer_Zone.ppt [Compatibility Mode]

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Outer Zone Th t f th C t l Pl t i b t 65 il The outer zone of the Central Plateau is about 65 square miles. Recovery Act funding will be used in this area to support shrinking the active footprint of cleanup to as little as 10 square miles in the center of the site. Work will consist mainly of demolishing facilities and remediating waste sites. Central Plateau, Outer Zone (~65 sq. mi.) * 200 North Area * Demolish spent fuel C o C o * Demolish spent fuel transfer storage facilities (212 N/P/R) *

  8. DOE to Invest up to $2.3 Million to Identify Renewable Energy Zones in

    Office of Environmental Management (EM)

    Western States | Department of Energy to Invest up to $2.3 Million to Identify Renewable Energy Zones in Western States DOE to Invest up to $2.3 Million to Identify Renewable Energy Zones in Western States May 28, 2008 - 1:58pm Addthis The Renewable Energy Zones Initiative will promote regional transmission planning and encourage the development of renewable sources of energy WASHINGTON, DC - U.S. Department of Energy (DOE) Assistant Secretary for Electricity Delivery and Energy Reliability

  9. Flow calculations for Yucca Mountain groundwater travel time (GWTT-95)

    SciTech Connect (OSTI)

    Altman, S.J.; Arnold, B.W.; Barnard, R.W.; Barr, G.E.; Ho, C.K.; McKenna, S.A.; Eaton, R.R.

    1996-09-01

    In 1983, high-level radioactive waste repository performance requirements related to groundwater travel time were defined by NRC subsystem regulation 10 CFR 60.113. Although DOE is not presently attempting to demonstrate compliance with that regulation, understanding of the prevalence of fast paths in the groundwater flow system remains a critical element of any safety analyses for a potential repository system at Yucca Mountain, Nevada. Therefore, this analysis was performed to allow comparison of fast-path flow against the criteria set forth in the regulation. Models developed to describe the conditions for initiation, propagation, and sustainability of rapid groundwater movement in both the unsaturated and saturated zones will form part of the technical basis for total- system analyses to assess site viability and site licensability. One of the most significant findings is that the fastest travel times in both unsaturated and saturated zones are in the southern portion of the potential repository, so it is recommended that site characterization studies concentrate on this area. Results support the assumptions regarding the importance of an appropriate conceptual model of groundwater flow and the incorporation of heterogeneous material properties into the analyses. Groundwater travel times are sensitive to variation/uncertainty in hydrologic parameters and in infiltration flux at upper boundary of the problem domain. Simulated travel times are also sensitive to poorly constrained parameters of the interaction between flow in fractures and in the matrix.

  10. Preliminary 3-D site-scale studies of radioactive colloid transortin the unsaturated zone at Yucca Mountain, Nevada

    SciTech Connect (OSTI)

    Moridis, G.J.; Hu, Q.; Wu, Y.-S.; Bodvarsson, G.S.

    2001-09-01

    The U.S: Department of Energy is actively investigating the technical feasibility of permanent disposal of high-level nuclear waste in a repository to be situated in the unsaturated zone at Yucca Mountain, Nevada. In this study we investigate, by means of numerical simulation, the transport of radioactive colloids under ambient conditions from the potential repository horizon to the water table. The site hydrology and the effects of the spatial distribution of hydraulic and transport properties in the Yucca Mountain subsurface are considered. The study of migration and retardation of colloids accounts for the complex processes in the unsaturated zone of Yucca Mountain, and includes advection, diffusion, hydrodynamic dispersion, kinetic colloid filtration, colloid straining, and radioactive decay. The results of the study indicate that the most important factors affecting colloid transport are the subsurface geology and site hydrology, i.e., the presence of faults (they dominate and control transport), fractures (the main migration pathways), and the relative distribution of zeolitic and vitric tuffs. The transport of colloids is strongly influenced by their size (as it affects diffusion into the matrix, straining at hydrogeologic unit interfaces, and transport velocity) and by the parameters of the kinetic-filtration model used for the simulations. Arrival times at the water table decrease with an increasing colloid size because of smaller diffusion, increased straining, and higher transport velocities. The importance of diffusion as a retardation mechanism increases with a decreasing colloid size, but appears to be minimal in large colloids.

  11. Trace element and isotope geochemistry of geothermal fluids, East Rift Zone, Kilauea, Hawaii

    SciTech Connect (OSTI)

    West, H.B.; Delanoy, G.A.; Thomas, D.M. . Hawaii Inst. of Geophysics); Gerlach, D.C. ); Chen, B.; Takahashi, P.; Thomas, D.M. Evans and Associates, Redwood City, CA )

    1992-01-01

    A research program has been undertaken in an effort to better characterize the composition and the precipitation characteristic of the geothermal fluids produced by the HGP-A geothermal well located on the Kilauea East Rift Zone on the Island of Hawaii. The results of these studies have shown that the chemical composition of the fluids changed over the production life of the well and that the fluids produced were the result of mixing of at least two, and possibly three, source fluids. These source fluids were recognized as: a sea water composition modified by high temperature water-rock reactions; meteoric recharge; and a hydrothermal fluid that had been equilibrated with high temperature reservoir rocks and magmatic volatiles. Although the major alkali and halide elements show clearly increasing trends with time, only a few of the trace transition metals show a similar trend. The rare earth elements, were typically found at low concentrations and appeared to be highly variable with time. Studies of the precipitation characteristics of silica showed that amorphous silica deposition rates were highly sensitive to fluid pH and that increases in fluid pH above about 8.5 could flocculate more than 80% of the suspended colloidal silica in excess of its solubility. Addition of transition metal salts were also found to enhance the recovery fractions of silica from solution. The amorphous silica precipitate was also found to strongly scavenge the alkaline earth and transition metal ions naturally present in the brines; mild acid treatments were shown to be capable of removing substantial fractions of the scavenged metals from the silica flocs yielding a moderately pure gelatinous by-product. Further work on the silica precipitation process is recommended to improve our ability to control silica scaling from high temperature geothermal fluids or to recover a marketable silica by-product from these fluids prior to reinjection.

  12. Fact #889: September 7, 2015 Average Diesel Price Lower than...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fact 889: September 7, 2015 Average Diesel Price Lower than Gasoline for the First Time in Six Years - Dataset Excel file and dataset for Average Diesel Price Lower than Gasoline ...

  13. RAPID/Roadmap/7-CA-e | Open Energy Information

    Open Energy Info (EERE)

    see: Green arrow.PNG 9-FD-a: BLM NEPA Process 7-CA-e.8 - Conduct Environmental, Reliability, and Mitigation Assessments At the same time that the BLM is conducting the Project...

  14. Conceptual Models for Migration of Key Groundwater Contaminants Through the Vadose Zone and Into the Upper Unconfined Aquifer Below the B-Complex

    SciTech Connect (OSTI)

    Serne, R. Jeffrey; Bjornstad, Bruce N.; Keller, Jason M.; Thorne, Paul D.; Lanigan, David C.; Christensen, J. N.; Thomas, Gregory S.

    2010-07-01

    The B-Complex contains 3 major crib and trench disposal sites and 3 SST farms that have released nearly 346 mega-liters of waste liquids containing the following high groundwater risk drivers: ~14,000 kg of CN, 29,000 kg of Cr, 12,000 kg of U and 145 Ci of Tc-99. After a thorough review of available vadose zone sediment and pore water, groundwater plume, field gamma logging, field electrical resistivity studies, we developed conceptual models for which facilities have been the significant sources of the contaminants in the groundwater and estimated the masses of these contaminants remaining in the vadose zone and currently present in the groundwater in comparison to the totals released. This allowed us to make mass balance calculations on how consistent our knowledge is on the current deep vadose zone and groundwater distribution of contaminants. Strengths and weaknesses of the conceptual models are discussed as well as implications on future groundwater and deep vadose zone remediation alternatives. Our hypothesized conceptual models attribute the source of all of the cyanide and most of the Tc-99 currently in the groundwater to the BY cribs. The source of the uranium is the BX-102 tank overfill event and the source of most of the chromium is the B-7-A&B and B-8 cribs. Our mass balance estimates suggest that there are much larger masses of U, CN, and Tc remaining in the deep vadose zone within ~20 ft of the water table than is currently in the groundwater plumes below the B-Complex. This hypothesis needs to be carefully considered before future remediation efforts are chosen. The masses of these groundwater risk drivers in the the groundwater plumes have been increasing over the last decade and the groundwater plumes are migrating to the northwest towards the Gable Gap. The groundwater flow rate appears to flucuate in response to seasonal changes in hydraulic gradient. The flux of contaminants out of the deep vadose zone from the three proposed sources also appears to be transient such that the evolution of the contaminant plumes is transient.

  15. BEAMLINE 7-2

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2 CURRENT STATUS: Open SUPPORTED TECHNIQUES: X-ray scattering X-ray diffraction MAIN SCIENTIFIC DISCIPLINES: Materials / Environmental % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 20-pole, 2-Tesla Wiggler ID End Station BEAM LINE SPECIFICATIONS: energy range resolution DE/E spot size flux angular acceptance focused 4600 - 16500 eV 0.12 x 0.50 mm 0.4 mrad OPTICS: Bent flat (vertical focusing) single crystal Si,

  16. BEAMLINE 7-3

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    3 CURRENT STATUS: Open SUPPORTED TECHNIQUES: X-ray absorption spectroscopy MAIN SCIENTIFIC DISCIPLINES: Structural Biology % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 20-pole, 2-Tesla wiggler, 0.8 mrad beam, side station BEAM LINE SPECIFICATIONS: energy range resolution DE/E spot size (fwhm) flux* angular acceptance unfocused 4600-37000 eV 1 x 10-4 2 x 15 mm2 ~1 x 1012 0.8 mrad *ph/sec @100 mA / 9 keV w 2x15 mm

  17. Time reversal communication system

    DOE Patents [OSTI]

    Candy, James V. (Danville, CA); Meyer, Alan W. (Danville, CA)

    2008-12-02

    A system of transmitting a signal through a channel medium comprises digitizing the signal, time-reversing the digitized signal, and transmitting the signal through the channel medium. The channel medium may be air, earth, water, tissue, metal, and/or non-metal.

  18. Time-Encoded Imagers.

    SciTech Connect (OSTI)

    Marleau, Peter; Brubaker, Erik

    2014-11-01

    This report provides a short overview of the DNN R&D funded project, Time-Encoded Imagers. The project began in FY11 and concluded in FY14. The Project Description below provides the overall motivation and objectives for the project as well as a summary of programmatic direction. It is followed by a short description of each task and the resulting deliverables.

  19. Time and Attendance Reporting

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2004-10-22

    DOE O 535.1 establishes the Department's requirements and responsibilities governing time and attendance reporting. The purpose of this revision is to reflect the transition of payroll processing from the Capital Accounting Center to the Defense Finance and Accounting System. Cancels DOE O 3600.1B. Canceled by DOE O 322.1C.

  20. Energy Literacy Essential Principle #7

    SciTech Connect (OSTI)

    2015-03-11

    Energy Literacy Essential Principle #7: The quality of life of individuals and societies is affected by energy choices.

  1. Microsoft Word - Part 7.doc

    Office of Environmental Management (EM)

    7 Page 7-1 of 6 PART 7 - POST-CLOSURE CARE PLAN 7.1. OVERVIEW This Part specifies the post-closure care requirements for the WIPP facility. Post-closure care requirements are applicable to Underground Hazardous Waste Disposal Units (Underground HWDUs) and include requirements for routine inspection and maintenance of the closed panel entry drifts, and air monitoring as required. Post-closure care requirements apply immediately after certification of closure of each Underground HWDU and continue

  2. ARM - Datastreams - goes7rad

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    rad Documentation XDC documentation Data Quality Plots ARM Data Discovery Browse Data Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Datastream : GOES7RAD GOES-7: radiance, channels 7, 10, 12

  3. H.R.S. 183C - Conservation District Zoning | Open Energy Information

    Open Energy Info (EERE)

    183C - Conservation District Zoning Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- StatuteStatute: H.R.S. 183C - Conservation District...

  4. Control of Well KS-8 in the Kilauea Lower East Rift Zone | Open...

    Open Energy Info (EERE)

    Control of Well KS-8 in the Kilauea Lower East Rift Zone Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Control of Well KS-8 in the Kilauea...

  5. From Fjords to Open Seas: Ecological Genomics of Expanding Oxygen Minimum Zones (2010 JGI User Meeting)

    ScienceCinema (OSTI)

    Hallam, Steven

    2011-04-26

    Steven Hallam of the University of British Columbia talks "From Fjords to Open Seas: Ecological Genomics of Expanding Oxygen Minimum Zones" on March 24, 2010 at the 5th Annual DOE JGI User Meeting

  6. Deep Vadose Zone Treatability Test for the Hanford Central Plateau: Soil Desiccation Pilot Test Results

    SciTech Connect (OSTI)

    Truex, Michael J.; Oostrom, Martinus; Strickland, Christopher E.; Johnson, Timothy C.; Freedman, Vicky L.; Johnson, Christian D.; Greenwood, William J.; Ward, Anderson L.; Clayton, Ray E.; Lindberg, Michael J.; Peterson, John E.; Hubbard, Susan; Chronister, Glen B.; Benecke, Mark W.

    2012-05-01

    This report describes results of a pilot test of soil desiccation conducted as part of the Deep Vadose Zone Treatability Test program. The report is written in CERCLA treatabilty test report format.

  7. AFIP-7 Tomography – 2013 Status Report

    SciTech Connect (OSTI)

    Craft, A. E.; Williams, W. J.; Abir, M. I.K.; Wachs, D. M.

    2013-10-01

    This project seeks to assess the geometric stability of the U-Mo monolithic fuel system by evaluating the radiation-induced changes in the AFIP-7 experiment device. Neutron radiography and computed tomography (CT) provide valuable information about the post-irradiation condition of the fuel specimen. Tomographic reconstructions of the AFIP-7 fuel element will be analyzed to assess the geometric condition of the element after irradiation and provide information regarding the condition of the fuel, including gross geometric defects, bowing, twist, plate buckling, cracks, and other defects. The INL, in collaboration with Oregon State University (OSU), Missouri University of Science and Technology (Missouri S&T), and Real Time Tomography, is developing advanced neutron detector systems and tomographic reconstruction techniques to evaluate the AFIP-7 fuel element. Neutron computed tomography using the current neutron radiography technique available at the Neutron Radiography reactor (NRAD) is impractical due to the long time and high cost to produce a set of images for tomographic reconstruction. Advanced neutron radiography systems such as the micro-channel plate (MCP) detector and neutron computed radiography (CR) may reduce the time and cost of acquiring images for neutron CT.

  8. New Approach to Assess Volatile Contamination in Vadose Zone Provides Path Forward for Site Closure

    Broader source: Energy.gov [DOE]

    RICHLAND, Wash. and LOS ALAMOS, N.M. – Through the Deep Vadose Zone-Applied Field Research Initiative (DVZ-AFRI), scientists and engineers from Pacific Northwest National Laboratory, CH2M HILL Plateau Remediation Company, federal agencies, and the scientific community are collaborating to develop effective, science-based solutions for remediating, characterizing, monitoring, and predicting the behavior and fate of deep vadose zone contamination.

  9. A Micro-Variable Circular Orifice (MVCO) Fuel Injector for Zoned Low

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Temperature Combustion | Department of Energy A Micro-Variable Circular Orifice (MVCO) Fuel Injector for Zoned Low Temperature Combustion A Micro-Variable Circular Orifice (MVCO) Fuel Injector for Zoned Low Temperature Combustion Presentation given at DEER 2006, August 20-24, 2006, Detroit, Michigan. Sponsored by the U.S. DOE's EERE FreedomCar and Fuel Partnership and 21st Century Truck Programs. PDF icon 2006_deer_hou.pdf More Documents & Publications Adaptive PCCI with Variable Orifice

  10. Mobility of Source Zone Heavy Metals and Radionuclides: The Mixed Roles of

    Office of Scientific and Technical Information (OSTI)

    Fermentative Activity on Fate and Transport of U and Cr (Technical Report) | SciTech Connect Mobility of Source Zone Heavy Metals and Radionuclides: The Mixed Roles of Fermentative Activity on Fate and Transport of U and Cr Citation Details In-Document Search Title: Mobility of Source Zone Heavy Metals and Radionuclides: The Mixed Roles of Fermentative Activity on Fate and Transport of U and Cr Predicting the potential migration of metals and radionuclides from waste pits and trenches will

  11. Microbial Activity and Precipitation at Solution-Solution Mixing Zones in

    Office of Scientific and Technical Information (OSTI)

    Porous Media -- Subsurface Biogeochemical Research (Technical Report) | SciTech Connect Microbial Activity and Precipitation at Solution-Solution Mixing Zones in Porous Media -- Subsurface Biogeochemical Research Citation Details In-Document Search Title: Microbial Activity and Precipitation at Solution-Solution Mixing Zones in Porous Media -- Subsurface Biogeochemical Research The goal for this research was to understand how best to add compounds to receptive microbial communities in porous

  12. An Updated Site Scale Saturated Zone Ground Water Transport Model for Yucca

    Office of Scientific and Technical Information (OSTI)

    Mountain. (Conference) | SciTech Connect An Updated Site Scale Saturated Zone Ground Water Transport Model for Yucca Mountain. Citation Details In-Document Search Title: An Updated Site Scale Saturated Zone Ground Water Transport Model for Yucca Mountain. Abstract not provided. Authors: Arnold, Bill Walter ; Kelkar, Sharad ; Ding, Mei ; Chu, Shaoping ; ROBINSON, BRUCE ; Meijer, Arend Publication Date: 2007-09-01 OSTI Identifier: 1147462 Report Number(s): SAND2007-5874C 521772 DOE Contract

  13. Remedy Evaluation Framework for Inorganic, Non-Volatile Contaminants in the Vadose Zone

    SciTech Connect (OSTI)

    Truex, Michael J.; Carroll, Kenneth C.

    2013-05-01

    Contaminants in the vadose zone may act as a potential long-term source of groundwater contamination and need to be considered in remedy evaluations. In many cases, remediation decisions for the vadose zone will need to be made all or in part based on projected impacts to groundwater. Because there are significant natural attenuation processes inherent in vadose zone contaminant transport, remediation in the vadose zone to protect groundwater is functionally a combination of natural attenuation and use of other remediation techniques, as needed, to mitigate contaminant flux to groundwater. Attenuation processes include both hydrobiogeochemical processes that serve to retain contaminants within porous media and physical processes that mitigate the rate of water flux. In particular, the physical processes controlling fluid flow in the vadose zone are quite different and generally have a more significant attenuation impact on contaminant transport relative to those within the groundwater system. A remedy evaluation framework is presented herein that uses an adaptation of the established EPA Monitored Natural Attenuation (MNA) evaluation approach and a conceptual model based approach focused on identifying and quantifying features and processes that control contaminant flux through the vadose zone. A key concept for this framework is to recognize that MNA will comprise some portion of all remedies in the vadose zone. Thus, structuring evaluation of vadose zone waste sites to use an MNA-based approach provides information necessary to either select MNA as the remedy, if appropriate, or to quantify how much additional attenuation would need to be induced by a remedial action (e.g., technologies considered in a feasibility study) to augment the natural attenuation processes and meet groundwater protection goals.

  14. Characterization of Vadose Zone Sediments from C Waste Management Area: Investigation of the C-152 Transfer Line Leak

    SciTech Connect (OSTI)

    Brown, Christopher F.; Serne, R. JEFFREY; Bjornstad, Bruce N.; Valenta, Michelle M.; Lanigan, David C.; Vickerman, Tanya S.; Clayton, Ray E.; Geiszler, Keith N.; Iovin, Cristian; Clayton, Eric T.; Kutynakov, I. V.; Baum, Steven R.; Lindberg, Michael J.; Orr, Robert D.

    2007-02-05

    A geologic/geochemical investigation in the vicinity of UPR-200-E-82 was performed using pairs of cone-penetrometer probe holes. A total of 41 direct-push cone-penetrometer borings (19 pairs to investigate different high moisture zones in the same sampling location and 3 individual) were advanced to characterize vadose zone moisture and the distribution of contaminants. A total of twenty sample sets, containing up to two split-spoon liners and one grab sample, were delivered to the laboratory for characterization and analysis. The samples were collected around the documented location of the C-152 pipeline leak, and created an approximately 120-ft diameter circle around the waste site. UPR-200-E-82 was a loss of approximately 2,600 gallons of Cs-137 Recovery Process feed solution containing an estimated 11,300 Ci of cesium-137 and 5 Ci of technetium-99. Several key parameters that are used to identify subsurface contamination were measured, including: water extract pH, electrical conductivity, nitrate, technetium-99, sodium, and uranium concentrations and technetium-99 and uranium concentrations in acid extracts. All of the parameters, with the exception of electrical conductivity, were elevated in at least some of the samples analyzed as part of this study. Specifically, soil pH was elevated (from 8.69 to 9.99) in five samples collected northeast and southwest of the C-152 pipeline leak. Similarly, samples collected from these same cone-pentrometer holes contained significantly more water-extractable sodium (more than 50 ?g/g of dry sediment), uranium (as much as 7.66E-01 ?g/g of dry sediment), nitrate (up to 30 ?g/g of dry sediment), and technetium-99 (up to 3.34 pCi/g of dry sediment). Most of the samples containing elevated concentrations of water-extractable sodium also had decreased levels of water extractable calcium and or magnesium, indicating that tank-related fluids that were high in sodium did seep into the vadose zone near these probe holes. Several of the samples containing high concentrations of water-leachable uranium also contained high pore water corrected alkalinity (3.26E+03 mg/L as CaCO3), indicating that the elevated water-leachable uranium could be an artifact of uranyl-carbonate complexation of naturally occurring labile uranium. However, a mass scan of the water extract containing the highest concentration of uranium was performed via inductively coupled mass spectrometry over the range of 230 to 240 atomic mass units, and a discernable peak was observed at mass 236. Although the data is considered qualitative, the presence of uranium-236 in the 1:1 sediment:water extract is a clear indication that the sample contains contaminant uranium [Hanford reprocessed fuel waste]. After evaluating all the characterization and analytical data, there is no question that the vadose zone surrounding the C-152 pipeline leak site has been contaminated by waste generally sent to tanks. The two zones or regions that contained the largest amount of contaminants, either in concentration or by occurrence of several key constituents/contaminants of concern, were located: 1) between the 241-C-151 and 241-C-152 Diversion Boxes (near the location of UPR-200-E-82) and 2) directly across the C-152 waste site near the C-153 Diversion Box (near where a pipeline, which connects the two diversion boxes, is shown on old blue prints . Without the use of more sophisticated analytical techniques, such as isotope signature analysis of ruthenium fission product isotopes, it is impossible to determine if the contamination observed at these two locations are from the same waste source or are a result of different leak events.

  15. Tevatron injection timing

    SciTech Connect (OSTI)

    Saritepe, S.; Annala, G.

    1993-06-01

    Bunched beam transfer from one accelerator to another requires coordination and synchronization of many ramped devices. During collider operation timing issues are more complicated since one has to switch from proton injection devices to antiproton injection devices. Proton and antiproton transfers are clearly distinct sequences since protons and antiprotons circulate in opposite directions in the Main Ring (MR) and in the Tevatron. The time bumps are different, the kicker firing delays are different, the kickers and lambertson magnets are different, etc. Antiprotons are too precious to be used for tuning purposes, therefore protons are transferred from the Tevatron back into the Main Ring, tracing the path of antiprotons backwards. This tuning operation is called ``reverse injection.`` Previously, the reverse injection was handled in one supercycle. One batch of uncoalesced bunches was injected into the Tevatron and ejected after 40 seconds. Then the orbit closure was performed in the MR. In the new scheme the lambertson magnets have to be moved and separator polarities have to be switched, activities that cannot be completed in one supercycle. Therefore, the reverse injection sequence was changed. This involved the redefinition of TVBS clock event $D8 as MRBS $D8 thus making it possible to inject 6 proton batches (or coalesced bunches) and eject them one at a time on command, performing orbit closure each time in the MR. Injection devices are clock event driven. The TCLK is used as the reference clock. Certain TCLK events are triggered by the MR beam synchronized clock (MRBS) events. Some delays are measured in terms of MRBS ticks and MR revolutions. See Appendix A for a brief description of the beam synchronized clocks.

  16. Evaluation of Soil Flushing for Application to the Deep Vadose Zone in the Hanford Central Plateau

    SciTech Connect (OSTI)

    Truex, Michael J.; Oostrom, Martinus; Zhang, Z. F.; Carroll, Kenneth C.; Schramke, Janet A.; Wietsma, Thomas W.; Tartakovsky, Guzel D.; Gordon, Kathryn A.; Last, George V.

    2010-11-01

    Soil flushing was included in the Deep Vadose Zone Treatability Test Plan for the Hanford Central Plateau as a technology with the potential to remove contaminants from the vadose zone. Soil flushing operates through the addition of water, and if necessary an appropriate mobilizing agent, to mobilize contaminants and flush them from the vadose zone and into the groundwater where they are subsequently captured by a pump-and-treat system. There are uncertainties associated with applying soil flushing technology to contaminants in the deep vadose zone at the Hanford Central Plateau. The modeling and laboratory efforts reported herein are intended to provide a quantitative assessment of factors that impact water infiltration and contaminant flushing through the vadose zone and into the underlying groundwater. Once in the groundwater, capture of the contaminants would be necessary, but this aspect of implementing soil flushing was not evaluated in this effort. Soil flushing was evaluated primarily with respect to applications for technetium and uranium contaminants in the deep vadose zone of the Hanford Central Plateau.

  17. Colloid Facilitated Transport of Radioactive Cations in the Vadose Zone: Field Experiments Oak Ridge

    SciTech Connect (OSTI)

    James E. Saiers

    2012-09-20

    The overarching goal of this study was to improve understanding of colloid-facilitated transport of radioactive cations through unsaturated soils and sediments. We conducted a suite of laboratory experiments and field experiments on the vadose-zone transport of colloids, organic matter, and associated contaminants of interest to the U.S. Department of Energy (DOE). The laboratory and field experiments, together with transport modeling, were designed to accomplish the following detailed objectives: 1. Evaluation of the relative importance of inorganic colloids and organic matter to the facilitation of radioactive cation transport in the vadose zone; 2. Assessment of the role of adsorption and desorption kinetics in the facilitated transport of radioactive cations in the vadose zone; 3. Examination of the effects of rainfall and infiltration dynamics and in the facilitated transport of radioactive cations through the vadose zone; 4. Exploration of the role of soil heterogeneity and preferential flow paths (e.g., macropores) on the facilitated transport of radioactive cations in the vadose zone; 5. Development of a mathematical model of facilitated transport of contaminants in the vadose zone that accurately incorporates pore-scale and column-scale processes with the practicality of predicting transport with readily available parameters.

  18. Measurement of the ratio of the production cross sections times branching fractions of Bc± ? J/??±and B± ? J/? K± and B(Bc±? J/? ?±?±?-/+)/B(Bc± ? J/? ?±) in pp collisions at ?s = 7 TeV

    SciTech Connect (OSTI)

    Khachatryan, V.

    2015-01-13

    The ratio of the production cross sections times branching fractions (?(Bc±) B(Bc± ? J/??±))/(?(B±) B(B± ? J/?K±) is studied in proton-proton collisions at a center-of-mass energy of 7 TeV with the CMS detector at the LHC. The kinematic region investigated requires Ba,sub>c± and B±mesons with transverse momentum p? > 15 GeV and rapidity |y| < 1.6. The data sample corresponds to an integrated luminosity of 5.1 fb-1. The ratio is determined to be [0.48 ± 0.05 (stat) ± 0.03(syst) ± 0.05 (?Bc)]% The J/??±?±?-/+ decay mode is also observed in the same data sample. Using a model-independent method developed to measure the efficiency given the presence of resonant behaviour in the three-pion system, the ratio of the branching fractions J/? ?±?±?-/+)/B(Bc± is measured to be 2.55 ± 0.80(stat) ± 0.33(syst) +0.04-0.01 (?Bc), consistent with the previous LHCb result.

  19. Measurement of the ratio of the production cross sections times branching fractions of $$B_{c}^{\\pm} \\to J/\\psi \\pi^{\\pm}$$ and $$B^{\\pm} \\to J/\\psi K^{\\pm}$$ and $$\\mathcal{B}(B_{c}^{\\pm} \\to J/\\psi \\pi^{\\pm}\\pi^{\\pm}\\pi^{\\mp})/\\mathcal{B}(B_{c}^{\\pm} \\to J/\\psi \\pi^{\\pm})$$ in pp collisions at $$\\sqrt{s} =$$ 7 TeV

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Khachatryan, Vardan

    2015-01-13

    The ratio of the production cross sections times branching fractions (σ(B±c)B(B±c→J/ψπ±))/(σ(B±)B(B±→J/ψK±)) is studied in proton-proton collisions at a center of-mass energy of 7 TeV with the CMS detector at the LHC. The kinematic region investigated requires B c ± and B± mesons with transverse momentum p T > 15 GeV and rapidity |y|< 1.6. The data sample corresponds to an integrated luminosity of 5.1 fb-1. The ratio is determined to be [0.48±0.05(stat)± 0.03(syst)±0.05 (τBc)]%. The B c ± → J/ψπ ± π ± π ∓ decay is also observed in the same data sample. Using a model-independent method developed tomore » measure the efficiency given the presence of resonant behaviour in the three-pion system, the ratio of the branching fractions B(B±c→J/ψπ±π±π∓)/B(B±c→J/ψπ±) is measured to be 2.55±0.80(stat)±0.33(syst)+0.04-0.01(τBc), consistent with the previous LHCb result.« less

  20. Nov 2010 The Y-12 Times

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    1 November 2010 www.y12.doe.gov/news/times.php P.O. Box 2009 Oak Ridge, TN 37831-8245 W H A T ' S I N S I D E Page 2 Dispositioning weapon components in real time Page 3 Off to sea Page 5 Y-12 through the decades Page 6 Catching up with retiree Sue Paulus Page 6 Exercise 24/7 on-site B&W Technical Services Y-12, LLC, a partnership between Babcock & Wilcox Technical Services Group Inc. and Bechtel National Inc., operates the Y-12 National Security Complex. A newsletter for employees and

  1. Vadose Zone Soil Moisture Wicking Using Super Absorbent Polymers

    SciTech Connect (OSTI)

    Oostrom, Martinus; Smoot, Katherine V.; Wietsma, Thomas W.; Truex, Michael J.; Benecke, Mark W.; Chronister, Glen B.

    2012-11-19

    Super-absorbent polymers (SAPs) have the potential to remove water and associated contaminants from unsaturated sediments in the field. Column and flow cell experiment were conducted to test the ability of four types of SAPs to remove water from unsaturated porous media. Column experiments, with emplacement of a layer of polymer on top of unsaturated porous media, showed the ability of the SAPs to extract up to 80% of the initially emplaced water against gravity into the sorbent over periods up to four weeks. In column experiments where the sorbent was emplaced between layers of unsaturated porous media, gel formation was observed at both the sorbent-porous medium interfaces. The extraction percentages over four weeks of contact time were similar for both column configurations and no obvious differences were observed for the four tested SAPs. Two different flow cells were used to test the wicking behavior of SAPs in two dimensions using three configurations. The largest removal percentages occurred for the horizontal sorbent layer configuration which has the largest sorbent-porous medium interfacial area. In a larger flow cell, a woven nylon “sock” was packed with sorbent and subsequently placed between perforated metal plates, mimicking a well configuration. After one week of contact time the sock was removed and replaced by a fresh sock. The results of this experiment showed that the sorbent was able to continuously extract water from the porous media, although the rate decreased over time. The declining yield during both periods is associated with the sharp reduction in water saturation and relative permeability near the sorbent. It was also observed that the capillary pressure continued to increase over the total contact time of 14 days, indicating that the sorbent remained active over that period. This work has demonstrated the potential of soil moisture wicking using SAPs at the proof-of-principle level.

  2. Aug 2010 Times

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    8 August 2010 www.y12.doe.gov/news/times.php P.O. Box 2009 Oak Ridge, TN 37831-8245 W H A T ' S I N S I D E Page 2 ARRA work continues Page 4 Sharing secrets with the public Page 5 Apprentices are a sure bet Page 6 Need a yo-yo? Stop by JA BizTown's Y-12 booth Page 8 Employees drop the pounds B&W Technical Services Y-12, LLC, a partnership between Babcock & Wilcox Technical Services Group Inc. and Bechtel National Inc., operates the Y-12 National Security Complex. A newsletter for

  3. Dec 09 Times

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2 December 2009 www.y12.doe.gov/news/times.php P.O. Box 2009 Oak Ridge, TN 37831-8245 W H A T ' S I N S I D E Pages 2 and 3 The Top 10 of 2009 Pages 4 and 5 More Q and A with Darrel Kohlhorst: What's ahead for 2010 Page 6 Holiday wishes to you and yours Page 8 Sharing the holiday spirit with those who protect our country B&W Technical Services Y-12, LLC, a partnership between Babcock & Wilcox Technical Services Group Inc. and Bechtel National Inc., operates the Y-12 National Security

  4. Real time Faraday spectrometer

    DOE Patents [OSTI]

    Smith, Jr., Tommy E. (Fremont, CA); Struve, Kenneth W. (Albuquerque, NM); Colella, Nicholas J. (Livermore, CA)

    1991-01-01

    This invention uses a dipole magnet to bend the path of a charged particle beam. As the deflected particles exit the magnet, they are spatially dispersed in the bend-plane of the magnet according to their respective momenta and pass to a plurality of chambers having Faraday probes positioned therein. Both the current and energy distribution of the particles is then determined by the non-intersecting Faraday probes located along the chambers. The Faraday probes are magnetically isolated from each other by thin metal walls of the chambers, effectively providing real time current-versus-energy particle measurements.

  5. Protocadherin-7 induces bone metastasis of breast cancer

    SciTech Connect (OSTI)

    Li, Ai-Min; Tian, Ai-Xian; Zhang, Rui-Xue; Ge, Jie; Key Laboratory of Breast Cancer Prevention and Treatment of the Ministry of Education, Tianjin Medical University Cancer Institute and Hospital, Tianjin ; Sun, Xuan; Cao, Xu-Chen; Key Laboratory of Breast Cancer Prevention and Treatment of the Ministry of Education, Tianjin Medical University Cancer Institute and Hospital, Tianjin

    2013-07-05

    Highlights: •PCDH7 is overexpression in high bone metastatic MDA-MB-231 cells. •PCDH7 is up-regulation in bone metastatic breast cancer tissues. •Suppression of PCDH7 inhibits cell proliferation, migration, and invasion in vitro. •PCDH7 induces breast cancer bone metastasis in vivo. -- Abstract: Breast cancer had a propensity to metastasize to bone, resulting in serious skeletal complications associated with poor outcome. Previous study showed that Protocadherin-7 (PCDH7) play an important role in brain metastatic breast cancer, however, the role of PCDH7 in bone metastatic breast cancer has never been explored. In the present study, we found that PCDH7 expression was up-regulation in bone metastatic breast cancer tissues by real-time PCR and immunohistochemistry assays. Furthermore, suppression of PCDH7 inhibits breast cancer cell proliferation, migration, and invasion in vitro by MTT, scratch, and transwell assays. Most importantly, overexpression of PCDH7 promotes breast cancer cell proliferation and invasion in vitro, and formation of bone metastasis in vivo. These data provide an important insight into the role of PCDH7 in bone metastasis of breast cancer.

  6. Technical Basis for Evaluating Surface Barriers to Protect Groundwater from Deep Vadose Zone Contamination

    SciTech Connect (OSTI)

    Fayer, Michael J.; Ward, Anderson L.; Freedman, Vicky L.

    2010-02-03

    This document presents a strategy for evaluating the effectiveness of surface barriers for site-specific deep vadose zone remediation. The strategy provides a technically defensible approach to determine the depth to which a surface barrier can effectively isolate contaminants in the vadose at a specific site as a function of subsurface properties, contaminant distribution, barrier design, and infiltration control performance. The strategy also provides an assessment of additional data and information needs with respect to surface barrier performance for deep vadose zone applications. The strategy addresses the linkage between surface barriers and deep vadose zone in situ remediation activities, monitoring issues, and emerging science, technology, and regulatory objectives. In short, the report documents the existing knowledge base, identifies knowledge needs (based on data gaps), and suggests tasks whose outcomes will address those knowledge needs. More important, the report serves as a starting point to engage the regulator and stakeholder community on the viability of deploying surface barriers for deep vadose zone contamination. As that engagement unfolds, a systematic methodology can be formalized and instituted. The strategy is focused on deep vadose zone contamination and the methods needed to determine the impact to groundwater from those deep vadose zone contaminants. Processes that affect surface barrier performance, recharge in the areas surrounding the surface barrier, and the near-surface vadose zone beneath the barrier are acknowledged but are not addressed by this strategy. In addition, the collection of site-specific data on contaminant distribution and geologic structure and properties are programmatic responsibilities and are not provided by this strategy.

  7. NERSC-6/7 Benchmarks

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    6/7 Benchmarks NERSC-6/7 Benchmarks The NERSC-6/7 application benchmarks were used in the acquisition process that resulted in the NERSC Cray XE6 ("Hopper") system and the follow on Cray XC30 system ("Edison") . A technical report describing the benchmark programs used in the NERSC-6 acquisition and the science drivers behind them is available here. Last edited: 2016-02-01 08:06:3

  8. Beamline 7.0.2

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7.0.2 Print Surface and Materials Science, Spectromicroscopy Scientific disciplines: Correlated electron system, materials science Endstations: nanoARPES (nARPES) EmicroARPES (Branchline 7.0.2.1) GENERAL BEAMLINE INFORMATION Operational No Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range See endstation tables Monochromator See endstation tables Scientific disciplines Correlated electron system, materials science Website Beamline 7:

  9. Beamline 7.0.2

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7.0.2 Print Surface and Materials Science, Spectromicroscopy Scientific disciplines: Correlated electron system, materials science Endstations: nanoARPES (nARPES) EmicroARPES (Branchline 7.0.2.1) GENERAL BEAMLINE INFORMATION Operational No Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range See endstation tables Monochromator See endstation tables Scientific disciplines Correlated electron system, materials science Website Beamline 7:

  10. Homeland Security Presidential Directive 7

    Office of Environmental Management (EM)

    7, 2003 Homeland Security Presidential Directive/Hspd-7 For Immediate Release Office of the Press Secretary December 17, 2003 December 17, 2003 Homeland Security Presidential Directive/Hspd-7 Subject: Critical Infrastructure Identification, Prioritization, and Protection Purpose (1) This directive establishes a national policy for Federal departments and agencies to identify and prioritize United States critical infrastructure and key resources and to protect them from terrorist attacks.

  11. TRANSIENT CHAOS AND FRACTAL STRUCTURES IN PLANETARY FEEDING ZONES

    SciTech Connect (OSTI)

    Kovács, T. [Also at University of Applied Sciences, Nagy Lajos kir. útja 1-9, H-1148 Budapest, Hungary. (Hungary); Regály, Zs. [Konkoly Observatory of the Hungarian Academy of Sciences, P.O. Box 67, H-1525 Budapest (Hungary)

    2015-01-01

    The circular restricted three-body problem is investigated in the context of accretion and scattering processes. In our model, a large number of identical non-interacting mass-less planetesimals are considered in the planar case orbiting a star-planet system. This description allows us to investigate the gravitational scattering and possible capture of the particles by the forming planetary embryo in a dynamical systems approach. Although the problem serves a large variety of complex motions, the results can be easily interpreted because of the low dimensionality of the phase space. We show that initial conditions define isolated regions of the disk, where planetesimals accrete or escape, which have, in fact, a fractal structure. The fractal geometry of these ''basins'' implies that the dynamics is very complex. Based on the calculated escape rates and escape times, it is also demonstrated that the planetary accretion rate is exponential for short times and follows a power law for longer integration. A new numerical calculation of the maximum mass that a planet can reach (described by the expression of the isolation mass) is also derived.

  12. WIPP UPDATE: April 7, 2014

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7, 2014 EPA to install additional air monitors This week, Environmental Protection Agency (EPA) employees will arrive at the Waste Isolation Pilot Plant (WIPP) to install...

  13. Beamline 7.3.1

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7.3.1 Print Photoemission electron microscope PEEM2 Scientific disciplines: Magnetism, materials, surface science, polymers Note: This beamline is NOT open to general users....

  14. TOUGH2/EOS7CA

    Energy Science and Technology Software Center (OSTI)

    003504MLTPL00 EOS7CA Version 1.0: TOUGH2 Module for Gas Migration in Shallow Subsurface Porous Media Systems   

  15. Wind 7 | Open Energy Information

    Open Energy Info (EERE)

    Name: Wind 7 Place: Eckernfoerde, Schleswig-Holstein, Germany Zip: 24340 Sector: Wind energy Product: Eckernfoerde-based company that develops & operates wind power projects in...

  16. Real time automated inspection

    DOE Patents [OSTI]

    Fant, K.M.; Fundakowski, R.A.; Levitt, T.S.; Overland, J.E.; Suresh, B.R.; Ulrich, F.W.

    1985-05-21

    A method and apparatus are described relating to the real time automatic detection and classification of characteristic type surface imperfections occurring on the surfaces of material of interest such as moving hot metal slabs produced by a continuous steel caster. A data camera transversely scans continuous lines of such a surface to sense light intensities of scanned pixels and generates corresponding voltage values. The voltage values are converted to corresponding digital values to form a digital image of the surface which is subsequently processed to form an edge-enhanced image having scan lines characterized by intervals corresponding to the edges of the image. The edge-enhanced image is thresholded to segment out the edges and objects formed by the edges by interval matching and bin tracking. Features of the objects are derived and such features are utilized to classify the objects into characteristic type surface imperfections. 43 figs.

  17. Real time automated inspection

    DOE Patents [OSTI]

    Fant, Karl M. (Minneapolis, MN); Fundakowski, Richard A. (Saint Paul, MN); Levitt, Tod S. (Minneapolis, MN); Overland, John E. (Plymouth, MN); Suresh, Bindinganavle R. (New Brighton, MN); Ulrich, Franz W. (Minneapolis, MN)

    1985-01-01

    A method and apparatus relating to the real time automatic detection and classification of characteristic type surface imperfections occurring on the surfaces of material of interest such as moving hot metal slabs produced by a continuous steel caster. A data camera transversely scans continuous lines of such a surface to sense light intensities of scanned pixels and generates corresponding voltage values. The voltage values are converted to corresponding digital values to form a digital image of the surface which is subsequently processed to form an edge-enhanced image having scan lines characterized by intervals corresponding to the edges of the image. The edge-enhanced image is thresholded to segment out the edges and objects formed by the edges are segmented out by interval matching and bin tracking. Features of the objects are derived and such features are utilized to classify the objects into characteristic type surface imperfections.

  18. Time encoded radiation imaging

    DOE Patents [OSTI]

    Marleau, Peter; Brubaker, Erik; Kiff, Scott

    2014-10-21

    The various technologies presented herein relate to detecting nuclear material at a large stand-off distance. An imaging system is presented which can detect nuclear material by utilizing time encoded imaging relating to maximum and minimum radiation particle counts rates. The imaging system is integrated with a data acquisition system that can utilize variations in photon pulse shape to discriminate between neutron and gamma-ray interactions. Modulation in the detected neutron count rates as a function of the angular orientation of the detector due to attenuation of neighboring detectors is utilized to reconstruct the neutron source distribution over 360 degrees around the imaging system. Neutrons (e.g., fast neutrons) and/or gamma-rays are incident upon scintillation material in the imager, the photons generated by the scintillation material are converted to electrical energy from which the respective neutrons/gamma rays can be determined and, accordingly, a direction to, and the location of, a radiation source identified.

  19. A hybrid hydrologic-geophysical inverse technique for the assessment and monitoring of leachates in the vadose zone. 1998 annual progress report

    SciTech Connect (OSTI)

    Alumbaugh, D.L.; Glass, R.J.; Yeh, T.C.; LaBrecque, D.

    1998-06-01

    'The objective of this study is to develop and field test a new, integrated Hybrid Hydrologic-Geophysical Inverse Technique (HHGIT) for characterization of the vadose zone at contaminated sites. This new approach to site characterization and monitoring can provide detailed maps of hydrogeological heterogeneity and the extent of contamination by combining information from electric resistivity tomography (ERT) surveys, statistical information about heterogeneity and hydrologic processes, and sparse hydrologic data. Because the electrical conductivity of the vadose zone (from the ERT measurements) can be correlated to the fluid saturation and/or contaminant concentration, the hydrologic and geophysical measurements are related. As of the 21st month of a 36-month project, a three-dimensional stochastic hydrologic inverse model for heterogeneous vadose zones has been developed. This model employs pressure and moisture content measurements under both transient and steady flow conditions to estimate unsaturated hydraulic parameters. In this model, an innovative approach to sequentially condition the estimate using temporal measurements has been incorporated. This allows us to use vast amounts of pressure and moisture content information measured at different times while keeping the computational effort manageable. Using this model the authors have found that the relative importance of the pressure and moisture content measurements in defining the different vadose zone parameters depends on whether the soil is wet or dry. They have also learned that pressure and moisture content measurements collected during steady state flow provide the best characterization of heterogeneity compared to other types of hydrologic data. These findings provide important guidance to the design of sampling scheme of the field experiment described below.'

  20. On the low carrier lifetime edge zone in multicrystalline silicon ingots

    SciTech Connect (OSTI)

    Jiang, Tingting; Yu, Xuegong; Wang, Lei; Gu, Xin; Yang, Deren, E-mail: mseyang@zju.edu.cn [State Key Laboratory of Silicon Materials and Department of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China)

    2014-01-07

    We have demonstrated the cause of low minority carrier lifetime corresponding to the edge zone of casting multicrystalline silicon ingots and its influence on the performance of solar cells. It is found that the concentration of substitutional carbon, interstitial oxygen, and dislocation density have no direct correlation with the low minority carrier lifetime in the edge zone. However, the distribution of interstitial iron exactly coincides with the minority carrier lifetime, indicating that iron contamination is mainly responsible for the lifetime degradation. After phosphorus diffusion gettering process, the low carrier lifetime region became narrower, and the concentration of interstitial iron is reduced by almost one order of magnitude. However, the carrier lifetime in the edge zone cannot be raised to average level. After celling process, the internal quantum efficiency map of the edge zone has a lower response to the long wavelength light, in accordance with the minority carrier lifetime distribution in this region. Therefore, the solar cells based on edge zones exhibit slightly lower efficiency than those conventional ones.