1

Air China will conduct China's first biofuel test flight (photo: Boeing announces major initiatives to develop, commercialize and fly sustainable jet biofuels in China  

E-Print Network [OSTI]

Air China will conduct China's first biofuel test flight (photo: Boeing) Boeing announces major initiatives to develop, commercialize and fly sustainable jet biofuels in China Fri 28 May 2010 ­ Boeing a sustainable aviation biofuels industry in the country. The US aircraft manufacturer says the strategic

2

NASA Boeing 757 HIRF test series low power on-the-ground tests  

SciTech Connect (OSTI)

The data acquisition phase of a program intended to provide data for the validation of computational, analytical, and experimental techniques for the assessment of electromagnetic effects in commercial transports; for the checkout of instrumentation for following test programs; and for the support of protection engineering of airborne systems has been completed. Funded by the NASA Fly-By-Light/ Power-By-Wire Program, the initial phase involved on-the-ground electromagnetic measurements using the NASA Boeing 757 and was executed in the LESLI Facility at the USAF Phillips Laboratory. The major participants in this project were LLNL, NASA Langley Research Center, Phillips Laboratory, and UIE, Inc. The tests were performed over a five week period during September through November, 1994. Measurements were made of the fields coupled into the aircraft interior and signals induced in select structures and equipment under controlled illumination by RF fields. A characterization of the ground was also performed to permit ground effects to be included in forthcoming validation exercises. This report and the associated test plan that is included as an appendix represent a definition of the overall on-the-ground test program. They include descriptions of the test rationale, test layout, and samples of the data. In this report, a detailed description of each executed test is provided, as is the data identification (data id) relating the specific test with its relevant data files. Samples of some inferences from the data that will be useful in protection engineering and EM effects mitigation are also presented. The test plan which guided the execution of the tests, a test report by UIE Inc., and the report describing the concrete pad characterization are included as appendices.

Poggio, A.J.; Pennock, S.T.; Zacharias, R.A.; Avalle, C.A.; Carney, H.L. [National Aeronautics and Space Administration, Langley AFB, VA (United States). Langley Research Center] [National Aeronautics and Space Administration, Langley AFB, VA (United States). Langley Research Center

1996-08-01T23:59:59.000Z

3

PROJECT BOEING SGS  

SciTech Connect (OSTI)

Boeing and its partner, PJM Interconnection, teamed to bring advanced “defense-grade” technologies for cyber security to the US regional power grid through demonstration in PJM’s energy management environment. Under this cooperative project with the Department of Energy, Boeing and PJM have developed and demonstrated a host of technologies specifically tailored to the needs of PJM and the electric sector as a whole. The team has demonstrated to the energy industry a combination of processes, techniques and technologies that have been successfully implemented in the commercial, defense, and intelligence communities to identify, mitigate and continuously monitor the cyber security of critical systems. Guided by the results of a Cyber Security Risk-Based Assessment completed in Phase I, the Boeing-PJM team has completed multiple iterations through the Phase II Development and Phase III Deployment phases. Multiple cyber security solutions have been completed across a variety of controls including: Application Security, Enhanced Malware Detection, Security Incident and Event Management (SIEM) Optimization, Continuous Vulnerability Monitoring, SCADA Monitoring/Intrusion Detection, Operational Resiliency, Cyber Range simulations and hands on cyber security personnel training. All of the developed and demonstrated solutions are suitable for replication across the electric sector and/or the energy sector as a whole. Benefits identified include: • Improved malware and intrusion detection capability on critical SCADA networks including behavioral-based alerts resulting in improved zero-day threat protection • Improved Security Incident and Event Management system resulting in better threat visibility, thus increasing the likelihood of detecting a serious event • Improved malware detection and zero-day threat response capability • Improved ability to systematically evaluate and secure in house and vendor sourced software applications • Improved ability to continuously monitor and maintain secure configuration of network devices resulting in reduced vulnerabilities for potential exploitation • Improved overall cyber security situational awareness through the integration of multiple discrete security technologies into a single cyber security reporting console • Improved ability to maintain the resiliency of critical systems in the face of a targeted cyber attack of other significant event • Improved ability to model complex networks for penetration testing and advanced training of cyber security personnel

Bell, Thomas

2014-12-31T23:59:59.000Z

4

Solutions to Test 1  

E-Print Network [OSTI]

Math 373. Spring 2013. Test 1. February 12, 2013. 1. Tracy is receiving an annuity immediate with quarterly payments of 250 for 10 years. Tracy invests each ...

Owner

2014-03-06T23:59:59.000Z

5

Solutions to Test 1  

E-Print Network [OSTI]

STAT 479. Spring 2014. Test 1. February 18, 2014. 1. You are given the following empirical distribution of losses: 300 500 700 800 1000 1400. An insurance ...

jeffb_000

2014-03-04T23:59:59.000Z

6

Solutions to Test 2  

E-Print Network [OSTI]

Jan 14, 2015 ... Test 2. Fall 2014. October 28, 2014. 1. Joon is going to buy a 10 year callable bond. The bond matures for 15,000 and pays semi-annual.

Microsoft account

2015-01-14T23:59:59.000Z

7

Solutions to Test 3  

E-Print Network [OSTI]

Math 373. Test 3. Spring 2014. April 8, 2014. 1. Yujin can buy each of the following bonds for a price of P . The bonds are: a. A 10 year zero coupon bond ...

jeffb_000

2014-08-16T23:59:59.000Z

8

Solutions to Test 1  

E-Print Network [OSTI]

MATH 373. Spring 2014. Test 1. February 18, 2013. 1. Amar wants to accumulate 1 million (1,000,000) by the time that he is 50 years old. Amar is currently 20 ...

jeffb_000

2014-08-16T23:59:59.000Z

9

Solutions to Test 2  

E-Print Network [OSTI]

STAT 479. Test 2. Spring 2014. April 1, 2014. 1. (5 points) You are given the following grouped data: Amount of claims. Number of Claims. 0 to 1000. 8. 1000 to ...

jeffb_000

2014-04-14T23:59:59.000Z

10

Solutions to Test 1  

E-Print Network [OSTI]

Test 1. STAT 47201. Fall 2014. October 7, 2014. 1. You are given: i. Mortality follows the illustrative life table ii. 6% i = Calculate: a. The actuarial present value

Microsoft account

2014-10-24T23:59:59.000Z

11

Solutions to Test 1  

E-Print Network [OSTI]

Test 1. September 26, 2013. 1. Zach buys a billiards table for his apartment. The cost of the table is 4000 and he uses a loan to pay for the table. The loan will be ...

jeffb_000

2014-02-16T23:59:59.000Z

12

Solutions to Test 2  

E-Print Network [OSTI]

Test 2. Spring 2013. March 5, 2013. 1. Jana purchased a 20 year zero coupon bond for 20,000. The bond matures for 70,000. Christian borrowed 50,000 to be ...

13

Solutions to Test 1  

E-Print Network [OSTI]

March 9, 2014. Math 373. Test 1. Fall 2012. September 27, 2012. 1. Meng takes out a loan to buy a new motorcycle. The amount of the loan is 12,500. Meng will.

Owner

2014-03-09T23:59:59.000Z

14

Solutions to Test 2  

E-Print Network [OSTI]

March 27, 2014. Math 373. Test 2. Fall 2013. October 17, 2013. 1. You are given the following table of interest rates: Year 1. Year 2. Year 3. Portfolio. Year. 2007.

jeffb_000

2014-03-26T23:59:59.000Z

15

Solutions to Test 3  

E-Print Network [OSTI]

April 5, 2014. Math 373. Test 3. Fall 2013. November 7, 2013. 1. You are given the following spot interest rate curve: Time t. Spot Rate tr. 0.5. 3.2%. 1.0. 3.5%. 1.5.

jeffb_000

2014-04-05T23:59:59.000Z

16

CORROSION TESTING IN SIMULATED TANK SOLUTIONS  

SciTech Connect (OSTI)

Three simulated waste solutions representing wastes from tanks SY-102 (high nitrate, modified to exceed guidance limits), AN-107, and AY-102 were supplied by PNNL. Out of the three solutions tested, both optical and electrochemical results show that carbon steel samples corroded much faster in SY-102 (high nitrate) than in the other two solutions with lower ratios of nitrate to nitrite. The effect of the surface preparation was not as strong as the effect of solution chemistry. In areas with pristine mill-scale surface, no corrosion occurred even in the SY-102 (high nitrate) solution, however, corrosion occurred in the areas where the mill-scale was damaged or flaked off due to machining. Localized corrosion in the form of pitting in the vapor space of tank walls is an ongoing challenge to overcome in maintaining the structural integrity of the liquid waste tanks at the Savannah River and Hanford Sites. It has been shown that the liquid waste condensate chemistry influences the amount of corrosion that occurs along the walls of the storage tanks. To minimize pitting corrosion, an effort is underway to gain an understanding of the pitting response in various simulated waste solutions. Electrochemical testing has been used as an accelerated tool in the investigation of pitting corrosion. While significant effort has been undertaken to evaluate the pitting susceptibility of carbon steel in various simulated waste solutions, additional effort is needed to evaluate the effect of liquid waste supernates from six Hanford Site tanks (AY-101, AY-102, AN-102, AN-107, SY-102 (high Cl{sup -}), and SY-102 (high nitrate)) on carbon steel. Solutions were formulated at PNNL to replicate tank conditions, and in the case of SY-102, exceed Cl{sup -} and NO{sub 3}{sup -} conditions, respectively, to provide a contrast between in and out of specification limits. The majority of previous testing has been performed on pristine polished samples. To evaluate the actual tank carbon steel surface, efforts are needed to compare the polished surfaces to corroded and mill-scale surfaces, which are more likely to occur in application. Additionally, due to the change in liquid waste levels within the tanks, salt deposits are highly likely to be present along the tank wall. When the level of the tank decreases, a salt deposit will form as the solution evaporates. The effects of this pre-existing salt, or supernate deposit, are unknown at this time on the corrosion effect and thus require investigation. Additionally, in the presence of radiation, moist air undergoes radiolysis, forming a corrosive nitric acid condensate. This condensate could accelerate the corrosion process in the vapor space. To investigate this process, an experimental apparatus simulating the effects of radiation was designed and constructed to provide gamma irradiation while coupons are exposed to a simulate tank solution. Additionally, ammonia vapors will also be introduced to further represent the tank environment.

Hoffman, E.

2010-12-09T23:59:59.000Z

17

Sandia National Laboratories: ECIS, Boeing, Caltrans, and Others...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

ClimateECResearch & CapabilitiesCapabilitiesECIS, Boeing, Caltrans, and Others: Fuel-Cell-Powered Mobile Lighting Applications ECIS, Boeing, Caltrans, and Others: Fuel-Cell-Powered...

18

Boeing Co | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectricEnergyCTBarre BiomassTHIS PAGE ISJumpSphere CorpBlundell 1BobcatBoeing Co

19

Atlas Material Testing Solutions | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectricEnergyCT BiomassArnprior, Ontario: EnergyAskjaAtlas Material Testing

20

The Boeing Company Project Fuel Tank Design Project Recap  

E-Print Network [OSTI]

The Boeing Company Project Fuel Tank Design Project Recap The Boeing Company came. Using solid baffles helps to separate the tank into separate and smaller sub tanks which helps to distribute and minimize the force of the slosh on the fuel tank. The problem in using solid baffles

Demirel, Melik C.

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Experience in testing of a solution mined storage cavern  

SciTech Connect (OSTI)

Recertification tests were made of the U.S. Department of Energy/Strategic Petroleum Reserve oil storage cavern No. 6 in the West Hackberry, LA, salt dome. The cavern has a volume of 8,600,000 bbl. Tests included hydrostatic tests of the brine filled cavern and nitrogen leak tests of the 3 wells entering the cavern. Test procedures are described and test results are discussed.

Goin, K.L.

1982-01-01T23:59:59.000Z

22

MECHANICAL TEST LAB CAPABILITIES  

E-Print Network [OSTI]

MECHANICAL TEST LAB CAPABILITIES · Static and cyclic testing (ASTM and non-standard) · Impact drop testing · Slow-cycle fatigue testing · High temperature testing to 2500°F · ASTM/ Boeing/ SACMA standard testing · Ability to design and fabricate non-standard test fixtures and perform non-standard tests

23

Cosmological solutions in bimetric gravity and their observational tests  

SciTech Connect (OSTI)

We obtain the general cosmological evolution equations for a classically consistent theory of bimetric gravity. Their analytic solutions are demonstrated to generically allow for a cosmic evolution starting out from a matter dominated FLRW universe and relaxing towards a de Sitter (anti-de Sitter) phase at late cosmic time. In particular, we examine a subclass of models which contain solutions that are able to reproduce the expansion history of the cosmic concordance model inspite of the nonlinear couplings of the two metrics. This is demonstrated explicitly by fitting these models to observational data from Type Ia supernovae, Cosmic Microwave Background and Baryon Acoustic Oscillations. In the appendix we comment on the relation to massive gravity.

Strauss, Mikael von; Schmidt-May, Angnis; Enander, Jonas; Mörtsell, Edvard; Hassan, S.F., E-mail: mvs@fysik.su.se, E-mail: angnis.schmidt-may@fysik.su.se, E-mail: enander@fysik.su.se, E-mail: edvard@fysik.su.se, E-mail: fawad@fysik.su.se [Department of Physics and The Oskar Klein Centre for Cosmoparticle Physics, Stockholm University, AlbaNova University Centre, SE-106 91 Stockholm (Sweden)

2012-03-01T23:59:59.000Z

24

Summary of Tests to Determine Effectiveness of Gelatin Strike on SS{ampersand}C Dissolver Solutions  

SciTech Connect (OSTI)

The solutions from the dissolution of sand, slag, and crucible (SS&C) material are sufficiently different from previous solutions processed via the F-Canyon Purex process that the effectiveness of individual process steps needed to be ascertained. In this study, the effectiveness of gelatin strike was tested under a variety of conditions. Specifically, several concentrations of silica, fluoride, nitric acid (HNO{sub 3}), boric acid (H{sub 3}BO{sub 3}), and aluminium nitrate nonahydrate (ANN) were studied. The disengagement times of surrogate and plant SS&C dissolver solutions from plant solvent also were measured. The results of the tests indicate that gelatin strike does not coagulate the silica at the low concentration of silica ({tilde 30} ppm) expected in the SS&C dissolver solutions because the silicon is complexed with fluoride ions (e.g., SiF{sub 6}{sup -2}). The silicon fluoride complex is expected to remain with the aqueous phase during solvent extraction. The disengagement times of the dissolver solutions from the plant solvent were not affected by the presence of low concentrations of silica and no third phase formation was observed in the disengagement phase with the low silica concentrations. Tests of surrogate SS&C dissolver solutions with higher concentration of silica (less than 150 ppm) did show that gelatin strike followed by centrifugation resulted in good phase disengagement of the surrogate SS{ampersand}C dissolver solution from the plant dissolver solution. At the higher silica concentrations, there is not sufficient fluoride to complex with the silica, and the silica must be entrained by the gelatin and removed from the dissolver solution prior to solvent extraction.

Murray, A.M. [Westinghouse Savannah River Company, AIKEN, SC (United States); Karraker, D.G.

1998-05-01T23:59:59.000Z

25

Sandia National Laboratories: Thermal Pulses for Boeing Test Article  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassiveSubmitted for USMaterials ProgramProtected: Tech Reference

26

File:EIA-Williston-NE-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100UP-LIQ.pdfWyoming Thrust Belt ByBOE

27

Classic tests of General Relativity described by brane-based spherically symmetric solutions  

E-Print Network [OSTI]

We discuss a way to obtain information about higher dimensions from observations by studying a brane-based spherically symmetric solution. The three classic tests of General Relativity are analyzed in details: the perihelion shift of the planet Mercury, the deflection of light by the Sun, and the gravitational redshift of atomic spectral lines. The braneworld version of these tests exhibits an additional parameter $b$ related to the fifth-coordinate. This constant $b$ can be constrained by comparison with observational data for massive and massless particles.

R. R. Cuzinatto; P. J. Pompeia; M. de Montigny; F. C. Khanna; J. M. Hoff da Silva

2014-09-03T23:59:59.000Z

28

An examination of Boeing's supply chain management practices within the context of the global aerospace industry  

E-Print Network [OSTI]

This thesis examines the supply chain management practices of the Boeing Commercial Airplane Company within the context of the global aerospace industry. The methodology used for this study includes a study of emerging ...

Çizmeci, DaÄŸ lar

2005-01-01T23:59:59.000Z

29

Site Environmental Report for Calendar Year 1999. DOE Operations at The Boeing Company, Rocketdyne  

SciTech Connect (OSTI)

OAK A271 Site Environmental Report for Calendar Year 1999. DOE Operations at The Boeing Company, Rocketdyne. This Annual Site Environmental Report (ASER) for 1999 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of the Rocketdyne Santa Susana Field Laboratory (SSFL). In the past, these operations included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials under the former Atomics International Division. Other activities included the operation of large-scale liquid metal facilities for testing of liquid metal fast breeder components at the Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility within Area IV. All nuclear work was terminated in 1988, and subsequently, all radiological work has been directed toward decontamination and decommissioning (D&D) of the previously used nuclear facilities and associated site areas. Large-scale D&D activities of the sodium test facilities began in 1996. This Annual Site Environmental Report provides information showing that there are no indications of any potential impact on public health and safety due to the operations conducted at the SSFL. All measures and calculations of off-site conditions demonstrate compliance with applicable regulations, which provide for protection of human health and the environment.

None

2000-09-01T23:59:59.000Z

30

Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade plutonium nitrate solutions  

E-Print Network [OSTI]

1.1 These test methods cover procedures for the chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade plutonium nitrate solutions to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Plutonium by Controlled-Potential Coulometry Plutonium by Amperometric Titration with Iron(II) Plutonium by Diode Array Spectrophotometry Free Acid by Titration in an Oxalate Solution 8 to 15 Free Acid by Iodate Precipitation-Potentiometric Titration Test Method 16 to 22 Uranium by Arsenazo I Spectrophotometric Test Method 23 to 33 Thorium by Thorin Spectrophotometric Test Method 34 to 42 Iron by 1,10-Phenanthroline Spectrophotometric Test Method 43 to 50 Impurities by ICP-AES Chloride by Thiocyanate Spectrophotometric Test Method 51 to 58 Fluoride by Distillation-Spectrophotometric Test Method 59 to 66 Sulfate by Barium Sulfate Turbidimetric Test Method 67 to 74 Isotopic Composition by Mass Spectrom...

American Society for Testing and Materials. Philadelphia

2010-01-01T23:59:59.000Z

31

A field test of electromagnetic geophysical techniques for locating simulated in situ mining leach solution  

SciTech Connect (OSTI)

The US Bureau of Mines, The University of Arizona, Sandia National Laboratories, and Zonge Engineering and Research Organization, Inc., conducted cooperative field tests of six electromagnetic (EM) geophysical methods to compare their effectiveness in locating a brine solution simulating in situ leach solution or a high-conductivity plume of contamination. The brine was approximately 160 m below the surface. The testsite was the University's San Xavier experimental mine near Tucson, AZ. Geophysical surveys using surface and surface-borehole, time-domain electromagnetic (TEM) induction; surface controlled-source audiofrequency magnetotellurics (CSAMT); surface-borehole, frequency-domain electromagnetic (FEM) induction; crosshole FEM; and surface magnetic field ellipticity were conducted before and during brine injection. The surface TEM data showed a broad decrease in resistivity. CSAMT measurements with the conventional orientation did not detect the brine, but measurements with another orientation indicated some decrease in resistivity. The surface-borehole and crosshole methods located a known fracture and other fracture zones inferred from borehole induction logs. Surface magnetic field ellipticity data showed a broad decrease in resistivity at depth following brine injection.

Tweeton, D.R.; Hanson, J.C.; Friedel, M.J.; Sternberg, B.K.; Dahl, L.J.

1994-01-01T23:59:59.000Z

32

Standard test method for nondestructive analysis of special nuclear materials in homogeneous solutions by Gamma-Ray spectrometry  

E-Print Network [OSTI]

1.1 This test method covers the determination of the concentration of gamma-ray emitting special nuclear materials dissolved in homogeneous solutions. The test method corrects for gamma-ray attenuation by the solution and its container by measurement of the transmission of a beam of gamma rays from an external source (Refs. (1), (2), and (3)). 1.2 Two solution geometries, slab and cylinder, are considered. The solution container that determines the geometry may be either a removable or a fixed geometry container. This test method is limited to solution containers having walls or a top and bottom of equal transmission through which the gamma rays from the external transmission correction source must pass. 1.3 This test method is typically applied to radionuclide concentrations ranging from a few milligrams per litre to several hundred grams per litre. The assay range will be a function of the specific activity of the nuclide of interest, the physical characteristics of the solution container, counting equip...

American Society for Testing and Materials. Philadelphia

2010-01-01T23:59:59.000Z

33

Portal solution for external test system Each year a number of driven and dedicated students write their thesis in collaboration with  

E-Print Network [OSTI]

: Test & Verifications Services Position: Student Skills Methodology: System design, user interface design, software testing analysis. Techniques: Experience from web development, good programming skillsPortal solution for external test system Each year a number of driven and dedicated students write

34

Model-based testing in the automotive industry challenges and solutions  

E-Print Network [OSTI]

Test specification System integration testing ­ model-based Test executionTest model Documentation... Requirements System integration testing ­ model-based SUT Sensors/busses Input interfaces Actors/busses Output interfaces #12;9 Overview 1. Model-based system integration testing 2. Integrating external models in the HW

Peleska, Jan - Fachbereich 3

35

Standard test method for isotopic analysis of hydrolyzed uranium hexafluoride and uranyl nitrate solutions by thermal ionization mass spectrometry  

E-Print Network [OSTI]

1.1 This method applies to the determination of isotopic composition in hydrolyzed nuclear grade uranium hexafluoride. It covers isotopic abundance of 235U between 0.1 and 5.0 % mass fraction, abundance of 234U between 0.0055 and 0.05 % mass fraction, and abundance of 236U between 0.0003 and 0.5 % mass fraction. This test method may be applicable to other isotopic abundance providing that corresponding standards are available. 1.2 This test method can apply to uranyl nitrate solutions. This can be achieved either by transforming the uranyl nitrate solution to a uranyl fluoride solution prior to the deposition on the filaments or directly by depositing the uranyl nitrate solution on the filaments. In the latter case, a calibration with uranyl nitrate standards must be performed. 1.3 This test method can also apply to other nuclear grade matrices (for example, uranium oxides) by providing a chemical transformation to uranyl fluoride or uranyl nitrate solution. 1.4 This standard does not purport to address al...

American Society for Testing and Materials. Philadelphia

2005-01-01T23:59:59.000Z

36

Experience in testing of a solution mined storage cavern. [Strategic Petroleum Reserve  

SciTech Connect (OSTI)

Recertification tests were made of the Department of Energy/Strategic Petroleum Reserve oil storage cavern number 6 in the West Hackberry, Louisiana Salt Dome. The cavern has a volume of 8,600,000 barrels. Tests included hydrostatic tests of the brine filled cavern and nitrogen leak tests of the three wells entering the cavern. Test procedures are described and test results are discussed.

Goin, K.L.

1982-01-01T23:59:59.000Z

37

Department of Energy Engineering Spring 2011 Boeing #2 Mechanical Energy Storage  

E-Print Network [OSTI]

PENNSTATE Department of Energy Engineering Spring 2011 Boeing #2 ­ Mechanical Energy Storage Overview The project was meant to show how well a mechanical energy storage system could compete of mechanical energy storage vs. battery storage is to provide a lower environmental impact. This would be due

Demirel, Melik C.

38

100-NR-2 Apatite Treatability Test FY09 Status: High Concentration Calcium-Citrate-Phosphate Solution Injection for In Situ Strontium-90 Immobilization  

SciTech Connect (OSTI)

100-NR-2 Apatite Treatability Test FY09 Status: High Concentration Calcium-Citrate-Phosphate Solution Injection for In Situ Strontium-90 Immobilization INTERIM LETTER REPORT

Vermeul, Vincent R.; Fritz, Brad G.; Fruchter, Jonathan S.; Szecsody, James E.; Williams, Mark D.

2009-12-16T23:59:59.000Z

39

Standard test method for isotopic abundance analysis of uranium hexa?uoride and uranyl nitrate solutions by multi-collector, inductively coupled plasma-mass spectrometry  

E-Print Network [OSTI]

Standard test method for isotopic abundance analysis of uranium hexa?uoride and uranyl nitrate solutions by multi-collector, inductively coupled plasma-mass spectrometry

American Society for Testing and Materials. Philadelphia

2008-01-01T23:59:59.000Z

40

Aerosol tests conducted at Aberdeen Proving Grounds MD.  

SciTech Connect (OSTI)

Test data are reported that demonstrate the deposition from a spray dispersion system (Illinois Tool Works inductively charging rotary atomization nozzle) for application of decontamination solution to various surfaces in the passenger cabin of a Boeing 737 aircraft. The decontamination solution (EnviroTru) was tagged with a known concentration of fluorescein permitting determination of both airborne decontaminant concentration and surface deposited decontaminant solution so that the effective deposition rates and surface coverage could be determined and correlated with the amount of material sprayed. Six aerosol dispersion tests were conducted. In each test, aluminum foil deposition coupons were set out throughout the passenger area and the aerosol was dispersed. The aerosol concentration was measured with filter samplers as well as with optical techniques Average aerosol deposition ranged from 3 to 15 grams of decontamination solution per square meter. Some disagreement was observed between various instruments utilizing different measurement principles. These results demonstrate a potentially effective method to disperse decontaminant to interior surfaces of a passenger aircraft.

Brockmann, John E.; Lucero, Daniel A.; Servantes, Brandon Lee; Hankins, Matthew Granholm

2012-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

A comparative analysis of supply chain management practices by Boeing and Airbus : long-term strategic implications  

E-Print Network [OSTI]

The goal of this research is to develop an improved understanding of supply chain management strategies and practices being pursued by Boeing and Airbus in the 787 Dreamliner and the A380 Navigator programs, respectively, ...

Horng, Tzu-Ching

2007-01-01T23:59:59.000Z

42

Testing large mixing MSW solutions of the solar neutrino problem through Earth regeneration effects  

E-Print Network [OSTI]

Large mixing MSW solutions to the solar neutrino problem appear to be currently favored by the data. We discuss the possibility of discriminating them by means of present and future experiments. In particular, we show that the study of energy and time dependence of the Earth regeneration effect can be useful in this respect.

Antonio Palazzo

2001-03-02T23:59:59.000Z

43

Testing of Dark Energy and a Solution of the Cosmological Constant Problem  

E-Print Network [OSTI]

A probable solution of the cosmological constant problem was recently found. We propose that dark energy of the Universe is vacuum energy. Our Universe during its expansion is spending its vacuum energy for creation of new quantum states, but in the quantum regime phase transitions were more effective in reducing the vacuum energy than creation of new quantum states. Here we show how the 123 crisis orders of the vacuum energy are reduced by conventional physical processes in both the quantum and classical regimes of the Universe evolution. Numeral estimates of dark energy evolution are also presented.

Vladimir Burdyuzha

2014-01-19T23:59:59.000Z

44

NREL Delivers In-Home HVAC Efficiency Testing Solutions (Fact Sheet)  

SciTech Connect (OSTI)

Researchers at the National Renewable Energy Laboratory (NREL) have recently developed two simple in-home efficiency test methods that can be used by technicians, researchers, or interested homeowners to verify the correct operation and energy efficiency of a home's air conditioning equipment. An efficiency validation method for mini-split heat pumps (MSHPs) - highly efficient refrigerant-based air conditioning and heating systems that permit room-by-room conditioning and control - will enable building researchers to easily explore the installed performance of this class of equipment. MSHPs are very popular overseas and are gaining market share in energy efficient home upgrades throughout the United States. Yet, because MSHPs have multiple variable-speed components that work in tandem, their performance is challenging to measure in a real home. NREL researchers developed a field evaluation method including test equipment, methods, and data analysis to determine the installed performance of this equipment in occupied homes. A field test was conducted to validate the method. When testing a home's operation, it is often important to simulate occupancy within an unoccupied home. That way, the researcher will know the actual usage profiles for heat and moisture generation; this removes the uncertainty associated with real occupants. The second test method details a standardized protocol for generating heat and moisture loads, to mimic occupants and their activities by using heaters and humidifiers. Realistic heat and moisture loads can be used to drive air conditioning systems, evaluate air distribution systems, and examine building enclosure technologies. These loads are drawn from the Building America House Simulation Protocols. Proper application of the method will result in better comparison between performance of the test home and its simulated analogue. This method is also validated by field testing. These test methods are now available in two technical reports. The methods can be used widely by the building research community to confirm proper operation of space conditioning equipment in homes, thereby improving thermal comfort, building health, and durability. National objectives for cost-effective energy savings in the residential sector can be met more quickly and with greater consistency.

Not Available

2012-01-01T23:59:59.000Z

45

Corrosion tests of 316L and Hastelloy C-22 in simulated tank waste solutions  

SciTech Connect (OSTI)

Both the 316L stainless steel and Hastelloy{reg_sign} C-22 gave satisfactory corrosion performance in the simulated test environments. They were subjected to 100 day weight loss corrosion tests and electrochemical potentiodynamic evaluation. This activity supports confirmation of the design basis for the materials of construction of process vessels and equipment used to handle the feed to the LAW-melter evaporator. BNFL process and mechanical engineering will use the information derived from this task to select material of construction for process vessels and equipment.

MJ Danielson; SG Pitman

2000-02-23T23:59:59.000Z

46

DOE/Boeing Sponsored Projects in Aviation Fuel Cell Technology...  

Broader source: Energy.gov (indexed) [DOE]

DOEBoeing will fund the build and field-test of 6 units for the purpose of duration and environmental testing: Current Funding and Plans We have an offer from the State of...

47

Line formation in the inner winds of classical T Tauri stars: testing the conical wind solution  

E-Print Network [OSTI]

We present the emission line profile models of hydrogen and helium based on the results from axisymmetric magnetohydrodynamics (MHD) simulations of the wind formed near the disk-magnetosphere boundary of classical T Tauri stars (CTTSs). We extend the previous outflow models of `the conical wind' by Romanova et al. to include a well defined magnetospheric accretion funnel flow which is essential for modelling the optical and near-infrared hydrogen and helium lines of CTTSs. Our MHD model shows outflows in conical shape with a half opening angle about 35 degrees. The flow properties such as the maximum outflow speed in the conical wind, maximum inflow speed in the accretion funnel, mass-accretion and mass-loss rates are comparable to those found in a typical CTTS. The density, velocity and temperature from the MHD simulations are used in a separate radiative transfer model to predict the line profiles and test the consistency of the MHD models with observations. The line profiles are computed with various combi...

Kurosawa, Ryuichi

2012-01-01T23:59:59.000Z

48

Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade uranyl nitrate solutions  

E-Print Network [OSTI]

1.1 These test methods cover procedures for the chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade uranyl nitrate solution to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Determination of Uranium 7 Specific Gravity by Pycnometry 15-20 Free Acid by Oxalate Complexation 21-27 Determination of Thorium 28 Determination of Chromium 29 Determination of Molybdenum 30 Halogens Separation by Steam Distillation 31-35 Fluoride by Specific Ion Electrode 36-42 Halogen Distillate Analysis: Chloride, Bromide, and Iodide by Amperometric Microtitrimetry 43 Determination of Chloride and Bromide 44 Determination of Sulfur by X-Ray Fluorescence 45 Sulfate Sulfur by (Photometric) Turbidimetry 46 Phosphorus by the Molybdenum Blue (Photometric) Method 54-61 Silicon by the Molybdenum Blue (Photometric) Method 62-69 Carbon by Persulfate Oxidation-Acid Titrimetry 70 Conversion to U3O8 71-74 Boron by ...

American Society for Testing and Materials. Philadelphia

1999-01-01T23:59:59.000Z

49

Standard test method for gamma energy emission from fission products in uranium hexafluoride and uranyl nitrate solution  

E-Print Network [OSTI]

1.1 This test method covers the measurement of gamma energy emitted from fission products in uranium hexafluoride (UF6) and uranyl nitrate solution. It is intended to provide a method for demonstrating compliance with UF6 specifications C 787 and C 996 and uranyl nitrate specification C 788. 1.2 The lower limit of detection is 5000 MeV Bq/kg (MeV/kg per second) of uranium and is the square root of the sum of the squares of the individual reporting limits of the nuclides to be measured. The limit of detection was determined on a pure, aged natural uranium (ANU) solution. The value is dependent upon detector efficiency and background. 1.3 The nuclides to be measured are106Ru/ 106Rh, 103Ru,137Cs, 144Ce, 144Pr, 141Ce, 95Zr, 95Nb, and 125Sb. Other gamma energy-emitting fission nuclides present in the spectrum at detectable levels should be identified and quantified as required by the data quality objectives. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its us...

American Society for Testing and Materials. Philadelphia

2005-01-01T23:59:59.000Z

50

Standard test method for evaluating stress-corrosion cracking of stainless alloys with different nickel content in boiling acidified sodium chloride solution  

E-Print Network [OSTI]

1.1 This test method describes a procedure for conducting stress-corrosion cracking tests in an acidified boiling sodium chloride solution. This test method is performed in 25% (by mass ) sodium chloride acidified to pH 1.5 with phosphoric acid. This test method is concerned primarily with the test solution and glassware, although a specific style of U-bend test specimen is suggested. 1.2 This test method is designed to provide better correlation with chemical process industry experience for stainless steels than the more severe boiling magnesium chloride test of Practice G36. Some stainless steels which have provided satisfactory service in many environments readily crack in Practice G36, but have not cracked during interlaboratory testing using this sodium chloride test method. 1.3 This boiling sodium chloride test method was used in an interlaboratory test program to evaluate wrought stainless steels, including duplex (ferrite-austenite) stainless and an alloy with up to about 33% nickel. It may also b...

American Society for Testing and Materials. Philadelphia

2000-01-01T23:59:59.000Z

51

Wide-Range Robust Control of Combustion Instability BOE-SHONG HONG, ASOK RAY, and VIGOR YANG*  

E-Print Network [OSTI]

time V Volume of combustion chamber Un Control input of nth mode vg Velocity of gas phase z AxialWide-Range Robust Control of Combustion Instability BOE-SHONG HONG, ASOK RAY, and VIGOR YANG This paper presents the concept and design of a two-layer robust control system for suppression of combustion

Ray, Asok

52

Underwater Unmanned Vehicle Boeing gave us the opportunity to compete against the Electrical Engineering Dept. The competition was  

E-Print Network [OSTI]

Underwater Unmanned Vehicle Overview Boeing gave us the opportunity to compete against Underwater Unmanned Vehicles. Basically we had to build remote controlled submarines from the ground up. Objectives To design a Underwater Unmanned Vehicle that meets the following Specs: Has an internal Ballast

Demirel, Melik C.

53

Commercial Aircraft Corporation of China (Comac) attempts to break the Airbus-Boeing duopoly, will it succeed? : an industry analysis framework applied  

E-Print Network [OSTI]

Using an industry analysis framework, this thesis analyzes whether the recently established Commercial Aircraft Corporation of China (Comac) is likely to break the Boeing-Airbus duopoly in the industry of large commercial ...

Fuentes, Jose L., S.M. Massachusetts Institute of Technology

2011-01-01T23:59:59.000Z

54

Civil aircraft accident Report on the Accident to Boeing 707-465 G-Arwe at Heathrow Airport, London on 8th April 1968   

E-Print Network [OSTI]

A3.C.A.P. 324 Civil aircraft accident Report on the Accident to Boeing 707-465 G-Arwe at Heathrow Airport, London on 8th April 1968...

Anonymous

1969-01-01T23:59:59.000Z

55

The Impact of the Item Types and Number of Solution Steps of Multiple-Choice Items on Item Difficulty and Discrimination and Test Reliability  

E-Print Network [OSTI]

The Impact of the Item Types and Number of Solution Steps of Multiple-Choice Items on Item Difficulty and Discrimination and Test Reliability By Erkan Hasan Atalmis Submitted to the graduate degree program in the Department of Psychology... ________________________________ Bruce Frey ________________________________ Marianne Perie ________________________________ Argun Saatcioglu ________________________________ William Skorupski Date Defended: 5/5/14 The Dissertation Committee for Erkan Hasan...

Atalmis, Erkan Hasan

2014-08-31T23:59:59.000Z

56

Solutions to Test 1 Review Problems 1. Here are two sound waves. Identify which is periodic. For the periodic wave, sketch a  

E-Print Network [OSTI]

Solutions to Test 1 Review Problems 1. Here are two sound waves. Identify which is periodic. Sound wave = You hear a sound that fades in, then gets quiet, then gets louder, and inally fades out. The width of the sound wave corresponds to intensity. (b) Suppose a 1000 Hz tone and a 1008 Hz tone

Hall, Rachel W.

57

100-NR-2 Apatite Treatability Test: High-Concentration Calcium-Citrate-Phosphate Solution Injection for In Situ Strontium-90 Immobilization  

SciTech Connect (OSTI)

Following an evaluation of potential strontium-90 (90Sr) treatment technologies and their applicability under 100-NR-2 hydrogeologic conditions, the U.S. Department of Energy (DOE), Fluor Hanford, Inc. (now CH2M Hill Plateau Remediation Company [CHPRC]), Pacific Northwest National Laboratory, and the Washington State Department of Ecology agreed that the long-term strategy for groundwater remediation at the 100-N Area should include apatite as the primary treatment technology. This agreement was based on results from an evaluation of remedial alternatives that identified the apatite permeable reactive barrier (PRB) technology as the approach showing the greatest promise for reducing 90Sr flux to the Columbia River at a reasonable cost. This letter report documents work completed to date on development of a high-concentration amendment formulation and initial field-scale testing of this amendment solution.

Vermeul, Vincent R.; Fritz, Brad G.; Fruchter, Jonathan S.; Szecsody, James E.; Williams, Mark D.

2010-09-01T23:59:59.000Z

58

Interim Report: 100-NR-2 Apatite Treatability Test: Low Concentration Calcium Citrate-Phosphate Solution Injection for In Situ Strontium-90 Immobilization  

SciTech Connect (OSTI)

Following an evaluation of potential Sr-90 treatment technologies and their applicability under 100-NR-2 hydrogeologic conditions, U.S. Department of Energy, Fluor Hanford, Inc., Pacific Northwest National Laboratory, and the Washington Department of Ecology agreed that the long-term strategy for groundwater remediation at 100-N Area will include apatite sequestration as the primary treatment, followed by a secondary treatment if necessary (most likely phytoremediation). Since then, the agencies have worked together to agree on which apatite sequestration technology has the greatest chance of reducing Sr-90 flux to the river at a reasonable cost. In July 2005, aqueous injection, (i.e., the introduction of apatite-forming chemicals into the subsurface) was endorsed as the interim remedy and selected for field testing. Studies are in progress to assess the efficacy of in situ apatite formation by aqueous solution injection to address both the vadose zone and the shallow aquifer along the 300 ft of shoreline where Sr-90 concentrations are highest. This report describes the field testing of the shallow aquifer treatment.

Williams, Mark D.; Fritz, Brad G.; Mendoza, Donaldo P.; Rockhold, Mark L.; Thorne, Paul D.; Xie, YuLong; Bjornstad, Bruce N.; Mackley, Rob D.; Newcomer, Darrell R.; Szecsody, James E.; Vermeul, Vincent R.

2008-07-11T23:59:59.000Z

59

The in-situ decontamination of sand and gravel aquifers by chemically enhanced solubilization of multiple-compound DNAPLs with surfactant solutions: Phase 1 -- Laboratory and pilot field-scale testing and Phase 2 -- Solubilization test and partitioning and interwell tracer tests. Final report  

SciTech Connect (OSTI)

Laboratory, numerical simulation, and field studies have been conducted to assess the potential use of micellar-surfactant solutions to solubilize chlorinated solvents contaminating sand and gravel aquifers. Ninety-nine surfactants were screened for their ability to solubilize trichloroethene (TCE), perchloroethylene (PCE), and carbon tetrachloride (CTET). The field test was conducted in the alluvial aquifer which is located 20 to 30 meters beneath a vapor degreasing operation at Paducah Gaseous Diffusion Plant. This aquifer has become contaminated with TCE due to leakage of perhaps 40,000 liters of TCE, which has generated a plume of dissolved TCE extending throughout an area of approximately 3 km{sup 2} in the aquifer. Most of the TCE is believed to be present in the overlying lacustrine deposits and in the aquifer itself as a dense, non-aqueous phase liquid, or DNAPL. The objective of the field test was to assess the efficacy of the surfactant for in situ TCE solubilization. Although the test demonstrated that sorbitan monooleate was unsuitable as a solubilizer in this aquifer, the single-well test was demonstrated to be a viable method for the in situ testing of surfactants or cosolvents prior to proceeding to full-scale remediation.

NONE

1997-10-24T23:59:59.000Z

60

Prototype to Test WHY prototype to test  

E-Print Network [OSTI]

Prototype to Test METHOD WHY prototype to test HOW to prototype to test Prototyping to test or design space. The fundamental way you test your prototypes is by letting users experience them and react to them. In creating prototypes to test with users you have the opportunity to examine your solution

Prinz, Friedrich B.

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Sandia National Laboratories: Boeing  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 -the Mid-Infrared0Energy Advanced NuclearBASFBoeing Patent Awarded for the Fuel Cell

62

Test Automation Test Automation  

E-Print Network [OSTI]

Test Automation Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2013 Mousavi: Test Automation #12;Test Automation Outline Test Automation Mousavi: Test Automation #12;Test Automation Why? Challenges of Manual Testing Test-case design: Choosing inputs

Mousavi, Mohammad

63

Building America Technology Solutions for New and Existing Homes...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Homes: Field Testing of Compartmentalization Methods for Multifamily Construction Building America Technology Solutions for New and Existing Homes: Field Testing of...

64

MATH 507: TEST 1.1 SOLUTIONS 1. Test 1.1 Solutions  

E-Print Network [OSTI]

(v1, . . . , vn) spans V . We define T(v) = a1w1 + . . . + anwn, which is well-defined because note that T is surjective, because (w1, . . . , wn) spans W, so every vector is of the form a1w1 + . . . + anwn = T(v) for some v in V . And T is injective, because if T(v) = a1w1 + . . . + anwn = 0, then all

Karagueuzian, Dikran

65

THE DAYLIGHTING SOLUTION  

E-Print Network [OSTI]

1980, pp.l4-20 THE DAYLIGHTING SOLUTION Stephen SelkowitzEEB-W·-80-19 W-74 THE DAYLIGHTING SOLUTION Stephen Selkowitz

Selkowitz, Stephen

2013-01-01T23:59:59.000Z

66

Financing Solutions | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solution Center Financing Solutions Financing Solutions Transitioning to a clean energy economy requires innovative financing solutions that enable state, local, and tribal...

67

PIA - Savannah River Nuclear Solution (SRNS) MedGate Occupational...  

Office of Environmental Management (EM)

Occupational Health and Safety Medical System (OHS) (Includes the Drug and Alcohol Testing System (Assistant)) PIA - Savannah River Nuclear Solution (SRNS) MedGate...

68

PIA - Savannah River Nuclear Solution (SRNS) Procurement Cycle...  

Energy Savers [EERE]

Occupational Health and Safety Medical System (OHS) (Includes the Drug and Alcohol Testing System (Assistant)) PIA - Savannah River Nuclear Solution (SRNS) Energy Employees...

69

PIA - Savannah River Nuclear Solution (SRNS) Energy Employees...  

Energy Savers [EERE]

Occupational Health and Safety Medical System (OHS) (Includes the Drug and Alcohol Testing System (Assistant)) PIA - Savannah River Nuclear Solution (SRNS) Procurement Cycle...

70

Sustainable Energy Solutions Task 4.2: UV Degradation Prevention on Fiber-Reinforced Composite Blades  

SciTech Connect (OSTI)

EXECUTIVE SUMARRY Use of wind energy has expanded very quickly because of the energy prices, environmental concerns and improved efficiency of wind generators. Rather than using metal and alloy based wind turbine blades, larger size fiber (glass and carbon) reinforced composite blades have been recently utilized to increase the efficiency of the wind energy in both high and low wind potential areas. In the current composite manufacturing, pre-preg and vacuum-assisted/heat sensitive resin transfer molding and resin infusion methods are employed. However, these lighter, stiffer and stronger composite blades experience ultraviolet (UV) light degradation where polymers (epoxies and hardeners) used for the blades manufacturing absorb solar UV lights, and cause photolytic, thermo-oxidative and photo-oxidative reactions resulting in breaking of carbon-hydrogen bonds, polymer degradation and internal and external stresses. One of the main reasons is the weak protective coatings/paints on the composite blades. This process accelerates the aging and fatigue cracks, and reduces the overall mechanical properties of the blades. Thus, the lack of technology on coatings for blade manufacturing is forcing many government agencies and private companies (local and national windmill companies) to find a better solution for the composite wind blades. Kansas has a great wind potential for the future energy demand, so efficient wind generators can be an option for continuous energy production. The research goal of the present project was to develop nanocomposite coatings using various inclusions against UV degradation and corrosion, and advance the fundamental understanding of degradation (i.e., physical, chemical and physiochemical property changes) on those coatings. In pursuit of the research goal, the research objective of the present program was to investigate the effects of UV light and duration on various nanocomposites made mainly of carbon nanotubes and graphene nanoflakes, contribute the valuable information to this emerging field of advanced materials and manufacturing and advance the Kansas economy through creation of engineering knowledge and products in the wind energy. The proposed work was involved in a multidisciplinary research program that incorporates nanocomposite fabrication, advanced coating, characterization, surface and colloidal chemistry, physicochemistry, corrosion science, and analysis with a simple and effective testing methodology. The findings were closely related to our hypothesis and approaches that we proposed in this proposal. The data produced in the study offered to advance the physical understanding of the behavior of nanostructured materials for the prevention of UV light at different exposure time and salt fogging. Founding of this proposal enabled the first UV resistive nanocomposite corrosion coating effort in Kansas to impact the local and national wind mill industry. Results of this program provided valuable opportunities for the multidisciplinary training of undergraduate and graduate students at Wichita State University (WSU), as well as a number of aircraft companies (e.g., Cessna, Hawker Beechcraft, Spirit, Boeing and Bombardier/Learjet) and other local and regional industries.

Janet M. Twomey, PhD

2010-04-30T23:59:59.000Z

71

Future Climate Engineering Solutions  

E-Print Network [OSTI]

Future Climate Engineering Solutions Joint report 13 engineering participating engeneering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Engineering Solutions ­ A Climate call from engineers. . . . . . . . . . . . . . . . . . . . .23 Summaries of National Reports . . . . . . . . . . . . . . . . . . . .25 Summary of The Climate Plan

72

Solution deposition assembly  

DOE Patents [OSTI]

Methods and devices are provided for improved deposition systems. In one embodiment of the present invention, a deposition system is provided for use with a solution and a substrate. The system comprises of a solution deposition apparatus; at least one heating chamber, at least one assembly for holding a solution over the substrate; and a substrate curling apparatus for curling at least one edge of the substrate to define a zone capable of containing a volume of the solution over the substrate. In another embodiment of the present invention, a deposition system for use with a substrate, the system comprising a solution deposition apparatus; at heating chamber; and at least assembly for holding solution over the substrate to allow for a depth of at least about 0.5 microns to 10 mm.

Roussillon, Yann; Scholz, Jeremy H; Shelton, Addison; Green, Geoff T; Utthachoo, Piyaphant

2014-01-21T23:59:59.000Z

73

Mixed oxide solid solutions  

DOE Patents [OSTI]

The present invention is a mixed oxide solid solution containing a tetravalent and a pentavalent cation that can be used as a support for a metal combustion catalyst. The invention is furthermore a combustion catalyst containing the mixed oxide solid solution and a method of making the mixed oxide solid solution. The tetravalent cation is zirconium(+4), hafnium(+4) or thorium(+4). In one embodiment, the pentavalent cation is tantalum(+5), niobium(+5) or bismuth(+5). Mixed oxide solid solutions of the present invention exhibit enhanced thermal stability, maintaining relatively high surface areas at high temperatures in the presence of water vapor.

Magno, Scott (Dublin, CA); Wang, Ruiping (Fremont, CA); Derouane, Eric (Liverpool, GB)

2003-01-01T23:59:59.000Z

74

Dispersant solutions for dispersing hydrocarbons  

DOE Patents [OSTI]

A dispersant solution includes a hydrocarbon dispersing solution derived from a bacterium from ATCC 75527, ATCC 75529, or ATCC 55638.

Tyndall, Richard L. (Clinton, TN)

1997-01-01T23:59:59.000Z

75

Dispersant solutions for dispersing hydrocarbons  

DOE Patents [OSTI]

A dispersant solution includes a hydrocarbon dispersing solution derived from a bacterium from ATCC 75527, ATCC 75529, or ATCC 55638.

Tyndall, R.L.

1997-03-11T23:59:59.000Z

76

Retained Gas Sampler Calibration and Simulant Tests  

SciTech Connect (OSTI)

This test plan provides a method for calibration of the retained gas sampler (RGS) for ammonia gas analysis. Simulant solutions of ammonium hydroxide at known concentrations will be diluted with isotopically labeled 0.04 M ammonium hydroxide solution. Sea sand solids will also be mixed with ammonium hydroxide solution and diluent to determine the accuracy of the system for ammonia gas analysis.

CRAWFORD, B.A.

2000-01-05T23:59:59.000Z

77

Well performance under solutions gas drive  

SciTech Connect (OSTI)

A fully implicit black-oil simulator was written to predict the drawdown and buildup responses for a single well under Solution Gas Drive. The model is capable of handling the following reservoir behaviors: Unfractured reservoir, Double-Porosity system, and Double Permeability-Double Porosity model of Bourdet. The accuracy of the model results is tested for both single-phase liquid flow and two-phase flow. The results presented here provide a basis for the empirical equations presented in the literature. New definitions of pseudopressure and dimensionless time are presented. By using these two definitions, the multiphase flow solutions correlate with the constant rate liquid flow solution for both transient and boundary-dominated flow. For pressure buildup tests, an analogue for the liquid solution is constructed from the drawdown pseudopressure, similar to the reservoir integral of J. Jones. The utility of using the producing gas-oil ration at shut in to compute pseudopressures and pseudotimes is documented. The influence of pressure level and skin factor on the Inflow Performance Relationship (IPR) of wells producing solution gas drive systems is examined. A new definition of flow efficiency that is based on the structure of the deliverability equations is proposed. This definition avoids problems that result when the presently available methods are applied to heavily stimulated wells. The need for using pseudopressures to analyze well test data for fractured reservoirs is shown. Expressions to compute sandface saturations for fractured systems are presented.

Camacho-Velazquez, R.G.

1987-01-01T23:59:59.000Z

78

Exact Solutions of Einstein's Field Equations  

E-Print Network [OSTI]

We examine various well known exact solutions available in the literature to investigate the recent criterion obtained in ref. [20] which should be fulfilled by any static and spherically symmetric solution in the state of hydrostatic equilibrium. It is seen that this criterion is fulfilled only by (i) the regular solutions having a vanishing surface density together with the pressure, and (ii) the singular solutions corresponding to a non-vanishing density at the surface of the configuration . On the other hand, the regular solutions corresponding to a non-vanishing surface density do not fulfill this criterion. Based upon this investigation, we point out that the exterior Schwarzschild solution itself provides necessary conditions for the types of the density distributions to be considered inside the mass, in order to obtain exact solutions or equations of state compatible with the structure of general relativity. The regular solutions with finite centre and non-zero surface densities which do not fulfill the criterion [20], in fact, can not meet the requirement of the `actual mass' set up by exterior Schwarzschild solution. The only regular solution which could be possible in this regard is represented by uniform (homogeneous) density distribution. The criterion [20] provides a necessary and sufficient condition for any static and spherical configuration (including core-envelope models) to be compatible with the structure of general relativity. Thus, it may find application to construct the appropriate core-envelope models of stellar objects like neutron stars and may be used to test various equations of state for dense nuclear matter and the models of relativistic stellar structures like star clusters.

P. S. Negi

2004-01-08T23:59:59.000Z

79

Materials Solutions for Hydrogen Delivery in Pipelines  

E-Print Network [OSTI]

Materials Solutions for Hydrogen Delivery in Pipelines Dr. Subodh K. Das Secat, Inc. September of new pipeline infrastructure Develop barrier coatings for minimizing hydrogen permeation in pipelines;NACE Hydrogen Induced Cracking (HIC) Test Evaluates resistance of pipeline and pressure vessel

80

Strategic Biomass Solutions (Mississippi)  

Broader source: Energy.gov [DOE]

The Strategic Biomass Solutions (SBS) was formed by the Mississippi Technology Alliance in June 2009. The purpose of the SBS is to provide assistance to existing and potential companies, investors...

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Solution to Quiz 1  

E-Print Network [OSTI]

Sep 5, 2013 ... over the next four years: Cash Flow at End of Year Amount of Cash Flow. 1. 1 Million. 2 ... project is 8%. Calculate X . Solution: By definition, the ...

jeffb_000

2014-01-14T23:59:59.000Z

82

Solutions of Penrose's Equation  

E-Print Network [OSTI]

The computational use of Killing potentials which satisfy Penrose's equation is discussed. Penrose's equation is presented as a conformal Killing-Yano equation and the class of possible solutions is analyzed. It is shown that solutions exist in spacetimes of Petrov type O, D or N. In the particular case of the Kerr background, it is shown that there can be no Killing potential for the axial Killing vector.

E. N. Glass; Jonathan Kress

1998-09-27T23:59:59.000Z

83

Prematurely terminated slug tests  

SciTech Connect (OSTI)

A solution of the well response to a prematurely terminated slug test (PTST) is presented. The advantages of a PTST over conventional slug tests are discussed. A systematized procedure of a PTST is proposed, where a slug test is terminated in the midpoint of the flow point, and the subsequent shut-in data is recorded and analyzed. This method requires a downhole shut-in device and a pressure transducer, which is no more than the conventional deep-well slug testing. As opposed to slug tests, which are ineffective when a skin is present, more accurate estimate of formation permeability can be made using a PTST. Premature termination also shortens the test duration considerably. Because in most cases no more information is gained by completing a slug test to the end, the author recommends that conventional slug tests be replaced by the premature termination technique. This study is part of an investigation of the feasibility of geologic isolation of nuclear wastes being carried out by the US Department of Energy and the National Cooperative for the Storage of Radioactive Waste of Switzerland.

Karasaki, K. (Lawrence Berkeley Lab., CA (USA))

1990-07-01T23:59:59.000Z

84

Geothermal: Sponsored by OSTI -- A closed-form analytical solution...  

Office of Scientific and Technical Information (OSTI)

A closed-form analytical solution for thermal single-well injection withdrawal tests Geothermal Technologies Legacy Collection HelpFAQ | Site Map | Contact Us HomeBasic Search...

85

Test Images  

E-Print Network [OSTI]

Test Images. I hope to have a set of test images for the course soon. Some images are available now; some will have to wait until I can find another 100-200

86

Senior Systems Analyst-PeopleSoft Campus Solutions Posting Details  

E-Print Network [OSTI]

and emerging technologies. This position may lead and coordinate the design, development, and implementation assurance and testing activities required to maintain business solutions. This position reportsSenior Systems Analyst-PeopleSoft Campus Solutions Posting Details Posting Details Position Title

Liblit, Ben

87

Fissile solution measurement apparatus  

DOE Patents [OSTI]

An apparatus for determining the content of a fissile material within a solution by detecting delayed fission neutrons emitted by the fissile material after it is temporarily irradiated by a neutron source. The apparatus comprises a container holding the solution and having a portion defining a neutron source cavity centrally disposed within the container. The neutron source cavity temporarily receives the neutron source. The container has portions defining a plurality of neutron detector ports that form an annular pattern and surround the neutron source cavity. A plurality of neutron detectors count delayed fission neutrons emitted by the fissile material. Each neutron detector is located in a separate one of the neutron detector ports.

Crane, T.W.; Collinsworth, P.R.

1984-06-11T23:59:59.000Z

88

Offshore Renewable Energy Solutions  

E-Print Network [OSTI]

power ­ to meet its target of achieving 15% of energy consumption from renewable sources by 2020. CefasOffshore Renewable Energy Solutions #12;Cefas: meeting complex requirements The Centre and maximise resource input on field and lab-based studies ­ saving you time and money.Recognised expertise

89

MA373 S12 Test 4 Solutions.pdf  

E-Print Network [OSTI]

May 1, 2012 ... (6 points) The current spot price of the stock of Johnson Corporation is .... Profit =

Owner

2014-05-01T23:59:59.000Z

90

Corrosion Testing of Carbon Steel in Acid Cleaning Solutions  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation Proposed Newcatalyst phases on γ-Al2O3. |ID#: 19834 Title: Correlation ofBurn89

91

Better Buildings Residential Program Solution Center Demonstration...  

Energy Savers [EERE]

Better Buildings Residential Program Solution Center Demonstration Better Buildings Residential Program Solution Center Demonstration Better Buildings Residential Program Solution...

92

Evaporation of Enriched Uranium Solutions Containing Organophosphates  

SciTech Connect (OSTI)

The Savannah River Site has enriched uranium (EU) solution which has been stored for almost 10 years since being purified in the second uranium cycle of the H area solvent extraction process. The preliminary SRTC data, in conjunction with information in the literature, is promising. However, very few experiments have been run, and none of the results have been confirmed with repeat tests. As a result, it is believed that insufficient data exists at this time to warrant Separations making any process or program changes based on the information contained in this report. When this data is confirmed in future testing, recommendations will be presented.

Pierce, R.A.

1999-03-18T23:59:59.000Z

93

Hollow cylinder dynamic pressurization and radial flow through permeability tests for cementitous materials  

E-Print Network [OSTI]

pressurization test is a potential solution for measuring concrete permeability. The hollow cylinder dynamic pressurization (HDP) test is compared with the radial flow through (RFT) test and the solid cylinder dynamic pressurization (SDP) test to assess...

Jones, Christopher Andrew

2009-05-15T23:59:59.000Z

94

Implementation and Test of Numerical Optimization  

E-Print Network [OSTI]

performance tests, and it is found that libopti is fast compared to scripting based solutions, and as much in its class. #12;ii #12;Summary (Danish) MÃ¥let for denne afhandling er at beskrive dobbelt-dimensional problems, their solution time is very large.[JN00] Because of this, optimization as we know it today did

95

Bearwall Energy Efficient Solutions  

E-Print Network [OSTI]

CATEE Conference November 20, 2014 ENERGY EFFICIENT SOLUTIONS ESL-KT-14-11-06 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 Brief History of Bearwall… Who We Are: ? Manuel Sovero ? Luis Osorio Energy Conservation... Experience: ESL-KT-14-11-06 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 Energy Programs… ESL-KT-14-11-06 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 Bearwall Methodology… Introduction...

Sovero,M.

2014-01-01T23:59:59.000Z

96

Cyanide Solution | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation Proposed Newcatalyst phases onOrganization FY 2012 FYCustomer-Comments SignCyanide Solution

97

Review: Greenhouse Solutions with Sustainable Energy  

E-Print Network [OSTI]

Solutions with Sustainable Energy By Mark DiesendorfSolutions with Sustainable Energy. Sydney, NSW: University

Hamilton-Smith, Elery

2009-01-01T23:59:59.000Z

98

Test Comparability  

E-Print Network [OSTI]

KU ScholarWorks | http://kuscholarworks.ku.edu Test Comparability 2010 by Christine Keller and David Shulenburger This work has been made available by the University of Kansas Libraries’ Office of Scholarly Communication and Copyright. Please... and Shulenburger, David. “Test comparability,” with Christine Keller in the Letters section of Change, September/October 2010, p. 6. Published version: http://www.changemag.org/Archives/Back%20 Issues/September-October%202010/letters-to-editor.html Terms of Use...

Keller, Christine; Shulenburger, David E.

2010-01-01T23:59:59.000Z

99

Software Testing and Maintenance 1 Regression Testing  

E-Print Network [OSTI]

1 Software Testing and Maintenance 1 Regression Testing Introduction Test Selection Test Minimization Test Prioritization Summary Software Testing and Maintenance 2 What is it? Regression testing refers to the portion of the test cycle in which a program is tested to ensure that changes do not affect

Lei, Jeff Yu

100

Test Automation Ant JUnit Test Automation  

E-Print Network [OSTI]

Test Automation Ant JUnit Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2012 Mousavi: Test Automation #12;Test Automation Ant JUnit Outline Test Automation Ant JUnit Mousavi: Test Automation #12;Test Automation Ant JUnit Why? Challenges of Manual Testing

Mousavi, Mohammad

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Singlehole GPR reflection imaging of solute transport in a granitic aquifer  

E-Print Network [OSTI]

Singlehole GPR reflection imaging of solute transport in a granitic aquifer Caroline Dorn,1 Niklas mmaperture fractures. A dipole tracer test was performed in a granitic aquifer by injecting a saline solution of solute transport in a granitic aquifer, Geophys. Res. Lett., 38, L08401, doi:10.1029/ 2011GL047152. 1

Paris-Sud XI, Université de

102

Soil Remediation Test  

SciTech Connect (OSTI)

Soils contaminated with petroleum by-products can now be effectively remediated using a variety of technologies. Among these are in-situ bioremediation, land farming, and landfill/replacing of soil. The range of efficiencies and cost effectiveness of these technologies has been well documented. Exsorbet Plus is showing promise as an in-situ bioremediation agent. It is made of naturally grown Spaghnum Peat Moss which has been activated for encapsulation and blended with nitrogen-rich fertilizer. In its initial field test in Caracas, Venezuela, it was able to remediate crude oil-contaminated soil in 90 days at less than half of the cost of competing technologies. Waste Solutions, Corp and the US Department of Energy signed a Cooperative Research and Development Agreement to test Exsorbet Plus at the Rocky Mountain Oilfield Testing Center near Casper, Wyoming. As part of the test, soil contaminated with crude oil was treated with Exsorbet Plus to aid the in-situ bioremediation process. Quantitative total petroleum hydrocarbon (TPH) measurements were acquired comparing the performance of Exsorbet Plus with an adjacent plot undergoing unaided in-situ bioremediation.

Manlapig, D. M.; Williamsws

2002-04-01T23:59:59.000Z

103

Verification Testing Test Driven Development Testing with JUnit Verification  

E-Print Network [OSTI]

Verification Testing Test Driven Development Testing with JUnit Verification Any activity should be verified. #12;Verification Testing Test Driven Development Testing with JUnit Approaches to verification 1 Testing 2 Static Analysis · Peer review · Insepction/Walk-through/Structured review · Formal

Peters, Dennis

104

PIA - Savannah River Nuclear Solutions Electronic Safeguards...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Solutions Electronic Safeguards Security System (E3S) PIA - Savannah River Nuclear Solutions Electronic Safeguards Security System (E3S) PIA - Savannah River Nuclear Solutions...

105

Verifying Test Hypotheses -HOL/TestGen Verifying Test Hypotheses -HOL/TestGen  

E-Print Network [OSTI]

Verifying Test Hypotheses - HOL/TestGen Verifying Test Hypotheses - HOL/TestGen An Experiment in Test and Proof Thomas Malcher January 20, 2014 1 / 20 #12;Verifying Test Hypotheses - HOL/TestGen HOL/TestGen Outline Introduction Test Hypotheses HOL/TestGen - Demo Verifying Test Hypotheses Conclusion 2 / 20 #12

106

Microgrid Testing  

SciTech Connect (OSTI)

With the publication of IEEE 1574.4 Guide for Design, Operation, and Integration of Distributed Resource Island Systems with Electric Power Systems, there is an increasing amount of attention on not only the design and operations of microgrids, but also on the proper operation and testing of these systems. This standard provides alternative approaches and good practices for the design, operation, and integration of microgrids. This includes the ability to separate from and reconnect to part of the utility grid while providing power to the islanded power system. This presentation addresses the industry need to develop standardized testing and evaluation procedures for microgrids in order to assure quality operation in the grid connected and islanded modes of operation.

Shirazi, M.; Kroposki, B.

2012-01-01T23:59:59.000Z

107

NSTAR (Electric)- Business Solutions Program  

Broader source: Energy.gov [DOE]

The Business Solutions Program offers NSTAR's non-residential customers incentives for a variety of energy efficient retrofit and new construction projects. Prescriptive rebates are available for...

108

Is Nuclear Energy the Solution?  

E-Print Network [OSTI]

009-0270-y Is Nuclear Energy the Solution? Milton H. Saier &in the last 50 years, nuclear energy subsidies have totaledadministration, the Global Nuclear Energy Partnership (GNEP)

Saier, Milton H.; Trevors, Jack T.

2010-01-01T23:59:59.000Z

109

Enhanced safeguards via solution monitoring  

SciTech Connect (OSTI)

Solution monitoring is defined as the essentially continuous monitoring of solution level, density, and temperature in all tanks in the process that contain, or could contain, safeguards-significant quantities of nuclear material. This report describes some of the enhancements that solution monitoring could make to international safeguards. The focus is on the quantifiable benefits of solution monitoring, but qualitatively, solution monitoring can be viewed as a form of surveillance. Quantitatively, solution monitoring can in some cases improve diversion detection probability. For example, the authors show that under certain assumptions, solution monitoring can be used to reduce the standard deviation of the annual material balance, {sigma}{sub MB}, from approximately 17 kg to approximately 4 kg. Such reduction in {sigma}{sub MB} will not always be possible, as they discuss. However, in all cases, solution monitoring would provide assurance that the measurement error models are adequate so that one has confidence in his estimate of {sigma}{sub MB}. Some of the results in this report were generated using data that were simulated with prototype solution monitoring software that they are developing. An accompanying document describes that software.

Burr, T.; Wangen, L.

1996-09-01T23:59:59.000Z

110

High conductivity electrolyte solutions and rechargeable cells incorporating such solutions  

DOE Patents [OSTI]

This invention relates generally to electrolyte solvents for use in liquid or rubbery polymer electrolyte solutions as are used, for example, in electrochemical devices. More specifically, this invention relates to sulfonyl/phospho-compound electrolyte solvents and sulfonyl/phospho-compound electrolyte solutions incorporating such solvents. 9 figs.

Angell, C.A.; Zhang, S.S.; Xu, K.

1998-10-20T23:59:59.000Z

111

Microfluidic-Based Robotic Sampling System for Radioactive Solutions  

SciTech Connect (OSTI)

A novel microfluidic based robotic sampling system has been developed for sampling and analysis of liquid solutions in nuclear processes. This system couples the use of a microfluidic sample chip with a robotic system designed to allow remote, automated sampling of process solutions in-cell and facilitates direct coupling of the microfluidic sample chip with analytical instrumentation. This system provides the capability for near real time analysis, reduces analytical waste, and minimizes the potential for personnel exposure associated with traditional sampling methods. A prototype sampling system was designed, built and tested. System testing demonstrated operability of the microfluidic based sample system and identified system modifications to optimize performance.

Jack D. Law; Julia L. Tripp; Tara E. Smith; Veronica J. Rutledge; Troy G. Garn; John Svoboda; Larry Macaluso

2014-02-01T23:59:59.000Z

112

Better Buildings Residential Program Solution Center Demonstration...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Program Solution Center Demonstration Webinar Transcript Better Buildings Residential Program Solution Center Demonstration Webinar Transcript The Better Buildings Residential...

113

Conference Agenda: Residential Energy Efficiency Solutions 2012...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Conference Agenda: Residential Energy Efficiency Solutions 2012 Conference Agenda: Residential Energy Efficiency Solutions 2012 Presents conference agenda including a general...

114

Presentation: Better Buildings Residential Program Solution Center...  

Energy Savers [EERE]

Presentation: Better Buildings Residential Program Solution Center Presentation: Better Buildings Residential Program Solution Center Presentation: Better Buildings Residential...

115

Better Buildings Residential Program Solution Center Demonstration...  

Energy Savers [EERE]

Better Buildings Residential Program Solution Center Demonstration Webinar Better Buildings Residential Program Solution Center Demonstration Webinar Demonstration webinar slides...

116

Toroidal solutions in Horava Gravity  

E-Print Network [OSTI]

Recently a new four-dimensional non relativistic renormalizable theory of gravity was proposed by Horava. This gravity reduces to Einstein gravity at large distances. In this paper by using the new action for gravity we present different toroidal solutions to the equations of motion. Our solutions describe the near horizon geometry with slow rotating parameter.

Ahmad Ghodsi

2011-02-24T23:59:59.000Z

117

Standard test method for static leaching of monolithic waste forms for disposal of radioactive waste  

E-Print Network [OSTI]

1.1 This test method provides a measure of the chemical durability of a simulated or radioactive monolithic waste form, such as a glass, ceramic, cement (grout), or cermet, in a test solution at temperatures radioactive waste forms in various leachants under the specific conditions of the test based on analysis of the test solution. Data from this test are used to calculate normalized elemental mass loss values from specimens exposed to aqueous solutions at temperatures <100°C. 1.3 The test is conducted under static conditions in a constant solution volume and at a constant temperature. The reactivity of the test specimen is determined from the amounts of components released and accumulated in the solution over the test duration. A wide range of test conditions can be used to study material behavior, includin...

American Society for Testing and Materials. Philadelphia

2010-01-01T23:59:59.000Z

118

Testing with JUnit Testing with JUnit  

E-Print Network [OSTI]

Testing with JUnit Testing with JUnit Running a test case: 1 Get the component to a known state (set up). 2 Cause some event (the test case). 3 Check the behaviour. · Record pass/fail · Track statistics · Typically we want to do a lot of test cases so it makes sense to automate. · Test cases

Peters, Dennis

119

Ryan T. Ratliff The Boeing Company,  

E-Print Network [OSTI]

@ceat.okstate.edu Design and Analysis of a Disk Drive Actuator for Commutational Ramp Loading A voice-coil motor actuator suspension spring constant, actuator angular velocity, and the ramp incline 5 . The suspension spring force

Pagilla, Prabhakar R.

120

BOE Technology Group | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 EastMaine: EnergyAustin Energy Place:Guidance DocumentsOperations | OpenBMETechnology

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Is Nuclear Energy the Solution?  

E-Print Network [OSTI]

10.1007/s11270-009-0270-y Is Nuclear Energy the Solution?MHS) attended a lecture on “Nuclear Responsibility” on theof the Alliance for Nuclear Responsibility. The information

Saier, Milton H.; Trevors, Jack T.

2010-01-01T23:59:59.000Z

122

Negative Energy Solutions and Symmetries  

E-Print Network [OSTI]

We revisit the negative energy solutions of the Dirac equation, which become relevant at very high energies and study several symmetries which follow therefrom. The consequences are briefly examined.

Burra G. Sidharth

2011-04-01T23:59:59.000Z

123

Dynamic Response Testing in an Electrically Heated Reactor Test Facility  

SciTech Connect (OSTI)

Non-nuclear testing can be a valuable tool in the development of a space nuclear power or propulsion system. In a non-nuclear test bed, electric heaters are used to simulate the heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system, but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and fueled nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response characteristics, and assess potential design improvements at a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE-100a heat pipe (HP) cooled, electrically heated reactor and heat exchanger hardware, utilizing a one-group solution to the point kinetics equations to simulate the expected neutronic response of the system. Reactivity feedback calculations were then based on a bulk reactivity feedback coefficient and measured average core temperature. This paper presents preliminary results from similar dynamic testing of a direct drive gas cooled reactor system (DDG), demonstrating the applicability of the testing methodology to any reactor type and demonstrating the variation in system response characteristics in different reactor concepts. Although the HP and DDG designs both utilize a fast spectrum reactor, the method of cooling the reactor differs significantly, leading to a variable system response that can be demonstrated and assessed in a non-nuclear test facility. Planned system upgrades to allow implementation of higher fidelity dynamic testing are also discussed. Proposed DDG testing will utilize a higher fidelity point kinetics model to control core power transients, and reactivity feedback will be based on localized feedback coefficients and several independent temperature measurements taken within the core block. This paper presents preliminary test results and discusses the methodology that will be implemented in follow-on DDG testing and the additional instrumentation required to implement high fidelity dynamic testing.

Bragg-Sitton, Shannon M. [NASA Marshall Space Flight Center, Nuclear and Advanced Propulsion Branch, ER-11, MSFC, AL 35812 (United States); Morton, T. J. [Department of Chemical and Nuclear Engineering, University of New Mexico, Albuquerque, NM 87131 (United States)

2006-01-20T23:59:59.000Z

124

SciTech Connect: A Solution for Solution-Produced [beta]-FeSe...  

Office of Scientific and Technical Information (OSTI)

A Solution for Solution-Produced beta-FeSe: Elucidating and Overcoming Factors that Prevent Superconductivity Citation Details In-Document Search Title: A Solution for...

125

Accelerated Testing Validation  

E-Print Network [OSTI]

the University of California. Accelerated Testing Validationmaterials requires relevant Accelerated Stress Tests (ASTs),

Mukundan, Rangachary

2013-01-01T23:59:59.000Z

126

Test Preparation Options Free Test Prep Websites  

E-Print Network [OSTI]

Test Preparation Options Free Test Prep Websites ACT: http: http://www.collegeboard.com/student/testing/sat/prep_one/test.html http://www.number2.com://testprep.princetonreview.com/CourseSearch/Search.aspx?itemCode=17&productType=F&rid=1&zip=803 02 Test Prep Classes Front Range Community College: Classes

Stowell, Michael

127

Test and Test Equipment Joshua Lottich  

E-Print Network [OSTI]

Test and Test Equipment Joshua Lottich CMPE 640 11/23/05 #12;Testing Verifies that manufactured chip meets design specifications. Cannot test for every potential defect. Modeling defects as faults allows for passing and failing of chips. Ideal test would capture all defects and pass only chips

Patel, Chintan

128

Orion Flight Test Exploration Flight Test-1  

E-Print Network [OSTI]

Orion Flight Test Exploration Flight Test-1 PRESS KIT/December 2014 www.nasa.gov NP-2014-11-020-JSC National Aeronautics and Space Administration #12;#12;Orion Flight Test December 2014 Contents Section Page ........................................................................................... 28 i #12;Orion Flight Test ii December 2014 #12;Orion Flight Test December 2014 Flight Overview

Waliser, Duane E.

129

Solar System tests of Ho?ava-Lifshitz black holes  

E-Print Network [OSTI]

In the present paper we consider the possibility of observationally testing Horava gravity at the scale of the Solar System, by considering the classical tests of general relativity (perihelion precession of the planet Mercury, deflection of light by the Sun and the radar echo delay) for the Kehagias-Sfetsos asymptotically flat black hole solution of Horava-Lifshitz gravity. All these gravitational effects can be fully explained in the framework of the vacuum solution of Horava gravity, and it is shown that the analysis of the classical general relativistic tests severely constrain the free parameter of the solution.

Francisco S. N. Lobo; Tiberiu Harko; Zoltán Kovács

2010-01-20T23:59:59.000Z

130

Modeling precipitation from concentrated solutions with the EQ3/6 chemical speciation codes  

SciTech Connect (OSTI)

One of the more important uncertainties of using chemical speciation codes to study dissolution and precipitation of compounds is the results of modeling which depends on the particular thermodynamic database being used. The authors goal is to investigate the effects of different thermodynamic databases on modeling precipitation from concentrated solutions. They used the EQ3/6 codes and the supplied databases to model precipitation in this paper. One aspect of this goal is to compare predictions of precipitation from ideal solutions to similar predictions from nonideal solutions. The largest thermodynamic databases available for use by EQ3/6 assume that solutions behave ideally. However, two databases exist that allow modeling nonideal solutions. The two databases are much less extensive than the ideal solution data, and they investigated the comparability of modeling ideal solutions and nonideal solutions. They defined four fundamental problems to test the EQ3/6 codes in concentrated solutions. Two problems precipitate Ca(OH){sub 2} from solutions concentrated in Ca{sup ++}. One problem tests the precipitation of Ca(OH){sub 2} from high ionic strength (high concentration) solutions that are low in the concentrations of precipitating species (Ca{sup ++} in this case). The fourth problem evaporates the supernatant of the problem with low concentrations of precipitating species. The specific problems are discussed.

Brown, L.F.; Ebinger, M.H.

1995-01-13T23:59:59.000Z

131

Project Management Plan Solution Stabilization  

SciTech Connect (OSTI)

This plan presents the overall objectives, description, justification and planning for the Plutonium Finishing Plant (PFP) Solutions Stabilization subproject. The intent of this plan is to describe how this project will be managed and integrated with other facility stabilization and deactivation activities. This plan supplements the overall integrated plan presented in the Integrated Project Management Plan (IPMP) for the Plutonium Finishing Plant Stabilization and Deactivation Project, HNF-3617. This project plan is the top-level definitive project management document for the PFP Solution Stabilization subproject. It specifies the technical, schedule, requirements and the cost baselines to manage the execution of the Solution Stabilization subproject. Any deviations to the document must be authorized through the appropriate change control process.

SATO, P.K.

1999-08-31T23:59:59.000Z

132

Interested Parties - Energy Solutions | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

- Energy Solutions EnergySolutions.pdf More Documents & Publications Interested Parties - NRG Energy Interested Parties - Myriant Interested Parties - 1603 Program Discussion...

133

Funding Opportunity Webinar - Advancing Solutions To Improve...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Funding Opportunity Webinar - Advancing Solutions To Improve the Energy Efficiency of US Commercial Buildings Funding Opportunity Webinar - Advancing Solutions To Improve the...

134

ITP Aluminum: Aluminum Industry Vision: Sustainable Solutions...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Aluminum Industry Vision: Sustainable Solutions for a Dynamic World ITP Aluminum: Aluminum Industry Vision: Sustainable Solutions for a Dynamic World alumvision.pdf More Documents...

135

Webinar Presentation: Energy Storage Solutions for Microgrids...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Presentation: Energy Storage Solutions for Microgrids (November 2012) Webinar Presentation: Energy Storage Solutions for Microgrids (November 2012) On November 7, 2012, Clean...

136

Blueprint for Sustainability - Sustainable Solutions for Every...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Blueprint for Sustainability - Sustainable Solutions for Every Consumer Blueprint for Sustainability - Sustainable Solutions for Every Consumer Highlights of Ford's near, mid, and...

137

Effective Darcy-scale contact angles in porous media imbibing solutions of various surface tensions  

E-Print Network [OSTI]

Effective Darcy-scale contact angles in porous media imbibing solutions of various surface tensions was to develop and test a methodology to determine whether these surface tension effects predictably alter of 25° for the NaNO3 solution solely on the basis of surface tension contrast. The results of this study

Selker, John

138

On an inverse problem: the recovery of non-smooth solutions to backward heat equation  

E-Print Network [OSTI]

On an inverse problem: the recovery of non-smooth solutions to backward heat equation Fabien Ternat solu- tions of backward heat equation. In this paper, we test the viability of using these techniques to recover non-smooth solutions of backward heat equation. In particular, we numerically integrate

Daripa, Prabir

139

Impact of delayed neutron precursor mobility in fissile solution systems  

SciTech Connect (OSTI)

A research version of the Monte Carlo software package MCNP6 is modified to incorporate advection and diffusion of delayed neutron precursors, resulting in the emission of delayed neutrons at locations different from the original fission sites. Results of two test problems, a pipe carrying flowing fissile solution and a sphere of fissile solution with precursor diffusion, show that the fission product mobility tends to perturb the fundamental mode, has a negative reactivity effect, and, perhaps most importantly, causes a decrease in the effective delayed neutron fraction. (authors)

Kiedrowski, B. C. [X-Computational Physics Div., Los Alamos National Laboratory, MS A143, P.O. Box 1663, Los Alamos, NM 87545 (United States)

2012-07-01T23:59:59.000Z

140

High frequency titration of amines in nonaqueous solutions  

E-Print Network [OSTI]

results for the aliphatkc amines and nitrogen hetero- cyclic compounds tested and fair results for some ef the aromatic compounds. An attempt to determine the individual amounts of two bases with one titration was unsuccessful. TABLE OF C05TE5TS I5... may be extended to include the titration of amines in nonaqueous solutions. The quantitative determination of amines in non- aqueous solutions is a field in which only a relatively small amount of work has been done, the major portion of which has...

Witmer, William Byron

1958-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Gravitational duality and rotating solutions  

SciTech Connect (OSTI)

We study how gravitational duality acts on rotating solutions, using the Kerr-NUT black hole as an example. After properly reconsidering how to take into account both electric (i.e. masslike) and magnetic (i.e. NUT-like) sources in the equations of general relativity, we propose a set of definitions for the dual Lorentz charges. We then show that the Kerr-NUT solution has nontrivial such charges. Further, we clarify in which respect Kerr's source can be seen as a mass M with a dipole of NUT charges.

Argurio, Riccardo; Dehouck, Francois [Physique Theorique et Mathematique and International Solvay Institutes, Universite Libre de Bruxelles, C.P. 231, 1050 Bruxelles (Belgium)

2010-03-15T23:59:59.000Z

142

Solution of simultaneous partial differential equations using dynamic ADI: Solution of the streamlined Darwin field equations  

SciTech Connect (OSTI)

We apply a particular version of ADI called Dynamic ADI (DADI) to the strongly coupled 2nd-order partial differential equations that arise from the streamlined Darwin field (SDF) equations. The DADI method a applied in a form that we show is guaranteed to converge to the desired solution of the finite difference equation. We give overviews of our test case, the SDF problem and the DADI method, with some justification for our choice of operator splitting. Finally, we apply DADI to the strongly coupled SDF equations and present the results from our test case. Our implementation requires a factor of 7 less storage and has proven to be a factor of 4 (in the worst case) to several orders of magnitude faster than competing methods. 13 refs., 3 figs., 5 tabs.

Hewett, D.W.; Larson, D.J.; Doss, S. (Lawrence Livermore National Lab., Livermore, CA (United States))

1992-07-01T23:59:59.000Z

143

Past Test One  

E-Print Network [OSTI]

MA 366: Introduction to Di?'erential Equations. Fall 2001, Test One. Instructor: Yip o This test booklet has FIVE QUESTIONS, totaling 50 points for the whole test.

144

Test Advising Framework.  

E-Print Network [OSTI]

??Test cases are represented in various formats depending on the process, the technique or the tool used to generate the tests. While different test case… (more)

Wang, Yurong

2013-01-01T23:59:59.000Z

145

Directed Test Suite Augmentation.  

E-Print Network [OSTI]

??Test suite augmentation techniques are used in regression testing to identify code elements affected by changes and to generate test cases to cover those elements.… (more)

Xu, Zhihong

2013-01-01T23:59:59.000Z

146

Solutions  

E-Print Network [OSTI]

Feb 16, 2012 ... Calculate the accumulated value of this annuity at the end of 5 years .... The Net Present Value of this project at 10% interest is 280,026.06 .

147

Solutions  

E-Print Network [OSTI]

10000= yields 2133.18 (Using BA 35 Solar keystrokes are AC/ON (to clear registers) ... In this question, first layer gives a value of 1/i (=PV of level perpetuity of 1 ...

CJordan

2005-09-19T23:59:59.000Z

148

Short communication: a larger clique for a DIMACS test  

E-Print Network [OSTI]

Abstract: In the DIMACS benchmark suite for the maximum clique problem, the best known solution for test C2000.9 is a 78 nodes clique; optimality is not proved

Andrea Grosso

149

Advanced Vehicle Testing - Beginning-of-Test Battery Testing...  

Broader source: Energy.gov (indexed) [DOE]

2.5 V Thermal Mgmt.: Passive, Vacuum-Sealed Unit Pack Weight: 294 kg BATTERY LABORATORY TEST RESULTS SUMMARY Vehicle Mileage and Testing Date Vehicle Odometer: 6,696 mi Date of...

150

Ozone decomposition in water solutions  

E-Print Network [OSTI]

. Hewes, III; B. S. , Texas ASH University Directed by Dr. R. R. Davison The rate of the decomposition of ozone in water solutions at various pH's and temperatures were ob- tained by an iodometrical method. The orders of the reactions and the reaction...

Hewes, Cecil Grayson

1969-01-01T23:59:59.000Z

151

Kampung Capacity Local Solutions for  

E-Print Network [OSTI]

Kampung Capacity Local Solutions for Sustainable Rural Energy in the Baram River Basin, Sarawak with a large-scale hydropower plan for the river basin. Keywords: South East Asia, Malaysia, Rural Energy In this study we explore the potential for rural renewable energy supply through a focus on villages

Kammen, Daniel M.

152

Active Waste Materials Corrosion and Decontamination Tests  

SciTech Connect (OSTI)

Stainless steel alloys, 304L and 316L, were corrosion tested in representative radioactive samples of three actual Hanford tank waste solutions (Tanks AW-101, C-104, AN-107). Both the 304L and 316L exhibited good corrosion performance when immersed in boiling waste solutions. The maximum general corrosion rate was 0.015 mm/y (0.60 mils per year). Generally, the 304L had a slightly higher rate than the 316L. No localized attack was observed after 122 days of testing in the liquid phase, liquid/vapor phase, or vapor phase. Radioactive plate-out decontamination tests indicated that a 24-hour exposure to 1 {und M} HNO{sub 3} could remove about 99% of the radioactive components in the metal film when exposed to the C-104 and AN-107 solutions. The decontamination results are less certain for the AW-101 solution, since the initial contamination readings exceeded the capacity of the meter used for this test.

MJ Danielson; MR Elmore; SG Pitman

2000-08-15T23:59:59.000Z

153

Introduction Statistical Tests  

E-Print Network [OSTI]

Introduction Statistical Tests Experiment Summary Statistical Significance Testing Machine Learning Lab, ASU Surendra Singhi April 29, 2005 Surendra Singhi Statistical Significance Testing #12;Introduction Statistical Tests Experiment Summary Outline 1 Introduction Preliminary Stuff Sources of Variation

Liu, Huan

154

Testing dynamically reconfigurable FPGAs  

E-Print Network [OSTI]

In this work, testing methods are proposed to test the ics. logic resources and the interconnect structure of dynamically reconfigurable FPGAS. Testing methods are also proposed for testing the dedicated CPU interface in these FPGAS. A BIST...

Ruiwale, Sameer Jagadish

1998-01-01T23:59:59.000Z

155

Bull Test ID 1140 2013 Florida Bull Test  

E-Print Network [OSTI]

Bull Test ID 1140 2013 Florida Bull Test #12;Bull Test ID 1141 2013 Florida Bull Test #12;Bull Test ID 1142 2013 Florida Bull Test #12;Bull Test ID 1143 2013 Florida Bull Test #12;Bull Test ID 1144 2013 Florida Bull Test #12;Bull Test ID 1145 2013 Florida Bull Test #12;Bull Test ID 1146 2013 Florida

Jawitz, James W.

156

Bull Test ID 1098 2013 Florida Bull Test  

E-Print Network [OSTI]

Bull Test ID 1098 2013 Florida Bull Test #12;Bull Test ID 1099 2013 Florida Bull Test #12;Bull Test ID 1100 2013 Florida Bull Test #12;Bull Test ID 1101 2013 Florida Bull Test #12;Bull Test ID 1102 2013 Florida Bull Test #12;Bull Test ID 1103 2013 Florida Bull Test #12;Bull Test ID 1104 2013 Florida

Jawitz, James W.

157

Bull Test ID 1181 2013 Florida Bull Test  

E-Print Network [OSTI]

Bull Test ID 1181 2013 Florida Bull Test #12;Bull Test ID 1182 2013 Florida Bull Test #12;Bull Test ID 1183 2013 Florida Bull Test #12;Bull Test ID 1184 2013 Florida Bull Test #12;Bull Test ID 1185 2013 Florida Bull Test #12;Bull Test ID 1186 2013 Florida Bull Test #12;Bull Test ID 1187 2013 Florida

Jawitz, James W.

158

Bull Test ID 1160 2013 Florida Bull Test  

E-Print Network [OSTI]

Bull Test ID 1160 2013 Florida Bull Test #12;Bull Test ID 1161 2013 Florida Bull Test #12;Bull Test ID 1162 2013 Florida Bull Test #12;Bull Test ID 1163 2013 Florida Bull Test #12;Bull Test ID 1164 2013 Florida Bull Test #12;Bull Test ID 1165 2013 Florida Bull Test #12;Bull Test ID 1166 2013 Florida

Jawitz, James W.

159

Bull Test ID 1118 2013 Florida Bull Test  

E-Print Network [OSTI]

Bull Test ID 1118 2013 Florida Bull Test #12;Bull Test ID 1119 2013 Florida Bull Test #12;Bull Test ID 1120 2013 Florida Bull Test #12;Bull Test ID 1121 2013 Florida Bull Test #12;Bull Test ID 1122 2013 Florida Bull Test #12;Bull Test ID 1123 2013 Florida Bull Test #12;Bull Test ID 1124 2013 Florida

Jawitz, James W.

160

Bull Test ID 1077 2013 Florida Bull Test  

E-Print Network [OSTI]

14th Annual Florida Bull Test #12;Bull Test ID 1077 2013 Florida Bull Test #12;Bull Test ID 1078 2013 Florida Bull Test #12;Bull Test ID 1079 2013 Florida Bull Test #12;Bull Test ID 1080 2013 Florida Bull Test #12;Bull Test ID 1081 2013 Florida Bull Test #12;Bull Test ID 1082 2013 Florida Bull Test #12

Jawitz, James W.

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Energy solutions?Director Eric Isaacs  

ScienceCinema (OSTI)

Argonne's Director Eric Isaacs talks about the laboratory's efforts for creating new, clean energy solutions.

Eric ISaacs

2013-06-05T23:59:59.000Z

162

Energy solutions—Director Eric Isaacs  

SciTech Connect (OSTI)

Argonne's Director Eric Isaacs talks about the laboratory's efforts for creating new, clean energy solutions.

Eric ISaacs

2012-08-08T23:59:59.000Z

163

Unit Testing Discussion C  

E-Print Network [OSTI]

Unit Testing Discussion C #12;Unit Test public Method is smallest unit of code Input/output transformation Test if the method does what it claims Not exactly black box testing #12;Test if (actual result Expected Computed Input #12;Functionality Computation ­ Easy to test Time based Asynchronous interaction

Massachusetts at Amherst, University of

164

Concolic Testing Koushik Sen  

E-Print Network [OSTI]

Concolic testing automates test input generation by com­ bining the concrete and symbolic (concolic) execution of the code under test. Traditional test input generation tech­ niques use either (1) concrete test inputs from these constraints. In contrast, concolic testing tightly couples both concrete

Sen, Koushik

165

Concolic Testing Koushik Sen  

E-Print Network [OSTI]

Concolic testing automates test input generation by com- bining the concrete and symbolic (concolic) execution of the code under test. Traditional test input generation tech- niques use either (1) concrete test inputs from these constraints. In contrast, concolic testing tightly couples both concrete

Sen, Koushik

166

An evaluation of spot tests for boron and the development of a superior spot test for boron  

E-Print Network [OSTI]

also to express his thanks to his wife, without whose help, understanding and en- couragement, this problem and thesis could not have been completed. COi& 2 nt) stract ~ ~ ~ ~ ~ s ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ * ~ * ~ ~ ~ lni;roduction e. 1 . iterature.... of concentxated. sulfuric acid is added to 1 or 2 drops of test solution followed by 1 or 2 dxops of the hydroxy- anthraquinone reagent, and the solution warmed. The color shift as described. above is the test for boron. Chromotro e 28& This reagent [ 4, 5...

Van Tuyl, Dixon Peacock

1954-01-01T23:59:59.000Z

167

A Behavioral Model of a Built-in Current Sensor for IDDQ Testing  

E-Print Network [OSTI]

IDDQ testing is one of the most effective methods for detecting defects in integrated circuits. Higher leakage currents in more advanced semiconductor technologies have reduced the resolution of IDDQ test. One solution is to use built-in current...

Gharaibeh, Ammar

2010-01-14T23:59:59.000Z

168

TESTING VAPOR SPACE AND LIQUID-AIR INTERFACE CORROSION IN SIMULATED ENVIRONMENTS OF HANFORD DOUBLE-SHELLED TANKS  

SciTech Connect (OSTI)

Electrochemical coupon testing were performed on 6 Hanford tank solution simulants and corresponding condensate simulants to evaluate the susceptibility of vapor space and liquid/air interface corrosion. Additionally, partial-immersion coupon testing were performed on the 6 tank solution simulants to compliment the accelerated electrochemical testing. Overall, the testing suggests that the SY-102 high nitrate solution is the most aggressive of the six solution simulants evaluated. Alternatively, the most passive solution, based on both electrochemical testing and coupon testing, was AY-102 solution. The presence of ammonium nitrate in the simulants at the lowest concentration tested (0.001 M) had no significant effect. At higher concentrations (0.5 M), ammonium nitrate appears to deter localized corrosion, suggesting a beneficial effect of the presence of the ammonium ion. The results of this research suggest that there is a threshold concentration of ammonium ions leading to inhibition of corrosion, thereby suggesting the need for further experimentation to identify the threshold.

Hoffman, E.

2013-05-30T23:59:59.000Z

169

Test Series 2. 3 detailed test plan  

SciTech Connect (OSTI)

Test Series 2.3 is chronologically the second of the five sub-series of tests which comprise Test Series 2, the second major Test Series as part of the combustion research phase to be carried out at the Grimethorpe Experimental Pressurised Fluidised Bed Combustion Facility. Test Series 2.3 will consist of 700 data gathering hours which is expected to require some 1035 coal burning hours. The tests will be performed using US supplied coal and dolomite. This will be the first major series of tests on the Facility with other than the UK datum coal and dolomite. The document summarises the background to the facility and the experimental program. Described are modifications which have been made to the facility following Test Series 2.1 and a series of Screening Tests. Detailed test objectives are specified as are the test conditions for the experiments which comprise the test series. The test results will provide information on the effects of the bed temperature, excess air level, Ca/S ratio, number of coal feed lines, and combustion efficiency and sulphur retention. A significant aspect of the test series will be part load tests which will investigate the performance of the facility under conditions of turn down which simulate load following concepts specified for two combined cycle concepts, i.e., their CFCC combined cycle and a turbo charged combined cycle. The material test plan is also presented. The principal feature of the materials programme is the planned exposure of a set of static turbine blade specimens in a cascade test loop to the high temperature, high pressure flue gas. A schedule for the programme is presented as are contingency plans.

Not Available

1983-12-01T23:59:59.000Z

170

Fissile solution dynamics: Student research  

SciTech Connect (OSTI)

There are two research projects in criticality safety at the University of Arizona: one in dynamic simulation of hypothetical criticality accidents in fissile solutions, and one in criticality benchmarks using transport theory. We have used the data from nuclear excursions in KEWB, CRAC, and SILENE to help in building models for solution excursions. An equation of state for liquids containing gas bubbles has been developed and coupled to point-reactor dynamics in an attempt to predict fission rate, yield, pressure, and kinetic energy. It appears that radiolytic gas is unimportant until after the first peak, but that it does strongly affect the shape of the subsequent power decrease and also the dynamic pressure.

Hetrick, D.L.

1994-09-01T23:59:59.000Z

171

Electrochromic Salts, Solutions, and Devices  

DOE Patents [OSTI]

Electrochromic salts. Electrochromic salts of dicationic viologens such as methyl viologen and benzyl viologen associated with anions selected from bis(trifluoromethylsulfonyl)imide, bis(perfluoroethylsulfonyl)imide, and tris(trifluoromethylsulfonyl)methide are produced by metathesis with the corresponding viologen dihalide. They are highly soluble in molten quarternary ammonium salts and together with a suitable reductant provide electrolyte solutions that are used in electrochromic windows.

Burrell, Anthony K. (Los Alamos, NM); Warner, Benjamin P. (Los Alamos, NM); McClesky, T. Mark (Los Alamos, NM)

2008-10-14T23:59:59.000Z

172

Electrochromic Salts, Solutions, and Devices  

DOE Patents [OSTI]

Electrochromic salts. Electrochromic salts of dicationic viologens such as methyl viologen and benzyl viologen associated with anions selected from bis(trifluoromethylsulfonyl)imide, bis(perfluoroethylsulfonyl)imide, and tris(trifluoromethylsulfonyl)methide are produced by metathesis with the corresponding viologen dihalide. They are highly soluble in molten quarternary ammonium salts and together with a suitable reductant provide electrolyte solutions that are used in electrochromic windows.

Burrell, Anthony K. (Los Alamos, NM); Warner, Benjamin P. (Los Alamos, NM); McClesky, T. Mark (Los Alamos, NM)

2008-11-11T23:59:59.000Z

173

Electrochromic salts, solutions, and devices  

DOE Patents [OSTI]

Electrochromic salts. Electrochromic salts of dicationic viologens such as methyl viologen and benzyl viologen associated with anions selected from bis(trifluoromethylsulfonyl)imide, bis(perfluoroethylsulfonyl)imide, and tris(trifluoromethylsulfonyl)methide are produced by metathesis with the corresponding viologen dihalide. They are highly soluble in molten quarternary ammonium salts and together with a suitable reductant provide electrolyte solutions that are used in electrochromic windows.

Burrell, Anthony K. (Los Alamos, NM); Warner, Benjamin P. (Los Alamos, NM); McClesky,7,064,212 T. Mark (Los Alamos, NM)

2006-06-20T23:59:59.000Z

174

Clean Energy Solutions Center (Presentation)  

SciTech Connect (OSTI)

The Clean Energy Ministerial launched the Clean Energy Solutions Center in April, 2011 for major economy countries, led by Australia and U.S. with other CEM partners. Partnership with UN-Energy is extending scope to support all developing countries: 1. Enhance resources on policies relating to energy access, small to medium enterprises (SMEs), and financing programs; 2. Offer expert policy assistance to all countries; 3. Expand peer to peer learning, training, and deployment and policy data for developing countries.

Reategui, S.

2012-07-01T23:59:59.000Z

175

Final Scientific Report - Wireless and Sensing Solutions Advancing Industrial Efficiency  

SciTech Connect (OSTI)

The project team's goal for the Wireless and Sensing Solution Advancing Industrial Efficiency award (DE-FC36-04GO14002) was to develop, demonstrate, and test a number of leading edge technologies that could enable the emergence of wireless sensor and sampling systems for the industrial market space. This effort combined initiatives in advanced sensor development, configurable sampling and deployment platforms, and robust wireless communications to address critical obstacles in enabling enhanced industrial efficiency.

Budampati, Rama; McBrady, Adam; Nusseibeh, Fouad

2009-09-28T23:59:59.000Z

176

Electrochemical Recovery of Sodium Hydroxide from Alkaline Salt Solution  

SciTech Connect (OSTI)

A statistically designed set of tests determined the effects of current density, temperature, and the concentrations of nitrate/nitrite, hydroxide and aluminate on the recovery of sodium as sodium hydroxide (caustic) from solutions simulating those produced from the Savannah River Site (SRS) In-Tank Precipitation process. These tests included low nitrate and nitrite concentrations which would be produced by electrolytic nitrate/nitrite destruction. The tests used a two compartment electrochemical cell with a Nafion Type 324 ion-exchange membrane. Caustic was successfully recovered from the waste solutions. Evaluation of the testing results indicated that the transport of sodium across the membrane was not significantly affected by any of the varied parameters. The observed variance in the sodium flux is attributed to experimental errors and variations in the performance characteristics of individual pieces of the organic-based Nafion membrane.Additional testing is recommended to determine the maximum current density, to evaluate the chemical durability of the organic membrane as a function of current density and to compare the durability and performance characteristics of the organic-based Nafion membrane with that of other commercially available organic membranes and the inorganic class of membranes under development by Ceramatec and PNNL.

Hobbs, D.T. [Westinghouse Savannah River Company, AIKEN, SC (United States); Edwards, T.B.

1996-10-01T23:59:59.000Z

177

Stability of exact force-free electrodynamic solutions and scattering from spacetime curvature  

E-Print Network [OSTI]

Recently, a family of exact force-free electrodynamic (FFE) solutions was discovered by Brennan, Gralla and Jacobson, which generalizes earlier solutions by Menon and Dermer, Michel, and other authors. These solutions have been proposed as useful models for describing the outer magnetosphere of conducting stars. As with any exact analytical solution that aspires to describe actual physical systems, it is vitally important that the solution possesses the necessary stability. In this paper, we show via fully nonlinear numerical simulations that the aforementioned FFE solutions, despite being highly special in their properties, are nonetheless stable under small perturbations. Through this study, we also introduce a three dimensional pseudo-spectral relativistic FFE code that achieves exponential convergence for smooth test cases, as well as two additional well-posed FFE evolution systems in the appendix that have desirable mathematical properties. Furthermore, we provide an explicit analysis that demonstrates h...

Zhang, Fan; Pfeiffer, Harald P

2015-01-01T23:59:59.000Z

178

Commercial Lighting Solutions Webtool Peer Review Report, Office Solutions  

SciTech Connect (OSTI)

The Commercial Lighting Solutions (CLS) project directly supports the U.S. Department of Energy’s Commercial Building Energy Alliance efforts to design high performance buildings. CLS creates energy efficient best practice lighting designs for widespread use, and they are made available to users via an interactive webtool that both educates and guides the end user through the application of the Lighting Solutions. This report summarizes the peer review of the CLS webtool for offices. The methodology for the peer review process included data collection (stakeholder input), analysis of the comments, and organization of the input into categories for prioritization of the comments against a set of criteria. Based on this process, recommendations were developed for the release of version 2.0 of the webtool at the Lightfair conference in Las Vegas in May 2010. The report provides a list of the top ten most significant and relevant improvements that will be made within the webtool for version 2.0 as well as appendices containing the comments and short-term priorities in additional detail. Peer review comments that are considered high priority by the reviewers and the CLS team but cannot be completed for Version 2.0 are listed as long-term recommendations.

Beeson, Tracy A.; Jones, Carol C.

2010-02-01T23:59:59.000Z

179

Training & Technology Solutions Queens College ~ Office of Converging Technologies ~ Training & Technology Solutions  

E-Print Network [OSTI]

Training & Technology Solutions Queens College ~ Office of Converging Technologies ~ Training & Technology Solutions 718-997-4875 ~ training@qc.cuny.edu ~ I-Bldg 214 Advisor Center Navigation: Login #12;Training & Technology Solutions Queens College ~ Office of Converging Technologies ~ Training

Johnson Jr.,, Ray

180

Equilibria in aqueous iodine solutions  

E-Print Network [OSTI]

for the determination of pH and. 1odide concentration. This instrument, reads pH to 0. 001 pH units and millivolts to F 1 mv. An Orion Specific Ion Electrode, Iodide Model 94-53, was used in the iodide determination. A Corning Triple Purpose pH glass elect- rode... with such electrodes fully confirms this statement. The optimum concentration of Solution I was found to be between 5 x 10 and 10 H iodide. Error in ZIIF Although short-term reproducibility to within 0. 001 26 pH unit can in principle be achieved. with the glass...

Burger, Joanne Denise

1970-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Singlet exciton fission in solution  

E-Print Network [OSTI]

Physics 135, 214508 (2011). 25. Sheraw, C. D., Jackson, T. N., Eaton, D. L. & Anthony, J. E. Functionalized Pentacene Active Layer Organic Thin-Film Transistors. Advanced Materials 15, 2009–2011 (2003). 26. Giri, G. et al. Tuning charge transport... in solution-sheared organic semiconductors using lattice strain. Nature 480, 504–8 (2011). 27. Gundlach, D. J. et al. Contact-induced crystallinity for high-performance soluble acene-based transistors and circuits. Nature Materials 7, 216–21 (2008). 28...

Walker, Brian J.; Musser, Andrew J.; Beljonne, David; Friend, Richard H.

2013-11-17T23:59:59.000Z

182

New Solutions Require New Thinking  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalanced Scorecard Federal2Energy SecondWellsWinsRules HelpSolutions Require

183

Soy Solutions | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to:Seadov Pty Ltd JumpGTZHolland, Illinois:5717551°Farms LtdLLC JumpSouthwoodSoy Solutions

184

Directed random testing  

E-Print Network [OSTI]

Random testing can quickly generate many tests, is easy to implement, scales to large software applications, and reveals software errors. But it tends to generate many tests that are illegal or that exercise the same parts ...

Pacheco, Carlos, Ph.D. Massachusetts Institute of Technology

2009-01-01T23:59:59.000Z

185

Test Herrera Report Template  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

development are described in detail in the following section. The model was run in six test sites: Test Site 1 is along the Cowlitz River (Segment 3); Test Site 2 includes the...

186

ZiaTest  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

ZiaTest ZiaTest Description This test executes a new proposed standard benchmark method for MPI startup that is intended to provide a realistic assessment of both launch and...

187

2015 Midwest Energy Solutions | Department of Energy  

Office of Environmental Management (EM)

2015 Midwest Energy Solutions 2015 Midwest Energy Solutions January 28, 2015 9:00AM EST to January 30, 2015 5:00PM EST Chicago, Illinois Learn more....

188

Correction-solution partielle des Feuilles 1 8 Exercice 1.1 : Solutions  

E-Print Network [OSTI]

STIA3 Correction-solution partielle des Feuilles 1 à 8 Exercice 1.1 : Solutions : Df = R+ Dg = Rn 5

Mas, André

189

Semianalytical Solutions of Radioactive or Reactive Tracer Transport in Layered Fractured Media  

SciTech Connect (OSTI)

In this paper, semianalytical solutions are developed for the problem of transport of radioactive or reactive tracers (solutes or colloids) through a layered system of heterogeneous fractured media with misaligned fractures. The tracer transport equations in the matrix account for (a) diffusion, (b) surface diffusion (for solutes only), (c) mass transfer between the mobile and immobile water fractions, (d) linear kinetic or equilibrium physical, chemical, or combined solute sorption or colloid filtration, and (e) radioactive decay or first order chemical reactions. Any number of radioactive decay daughter products (or products of a linear, first-order reaction chain) can be tracked. The tracer-transport equations in the fractures account for the same processes, in addition to advection and hydrodynamic dispersion. Additionally, the colloid transport equations account for straining and velocity adjustments related to the colloidal size. The solutions, which are analytical in the Laplace space, are numerically inverted to provide the solution in time and can accommodate any number of fractured and/or porous layers. The solutions are verified using analytical solutions for limiting cases of solute and colloid transport through fractured and porous media. The effect of important parameters on the transport of {sup 3}H, {sup 237}Np and {sup 239}Pu (and its daughters) is investigated in several test problems involving layered geological systems of varying complexity. {sup 239}Pu colloid transport problems in multilayered systems indicate significant colloid accumulations at straining interfaces but much faster transport of the colloid than the corresponding strongly sorbing solute species.

G.J. Moridis; G. S. Bodvarsson

2001-10-01T23:59:59.000Z

190

Vendor System Vulnerability Testing Test Plan  

SciTech Connect (OSTI)

The Idaho National Laboratory (INL) prepared this generic test plan to provide clients (vendors, end users, program sponsors, etc.) with a sense of the scope and depth of vulnerability testing performed at the INL’s Supervisory Control and Data Acquisition (SCADA) Test Bed and to serve as an example of such a plan. Although this test plan specifically addresses vulnerability testing of systems applied to the energy sector (electric/power transmission and distribution and oil and gas systems), it is generic enough to be applied to control systems used in other critical infrastructures such as the transportation sector, water/waste water sector, or hazardous chemical production facilities. The SCADA Test Bed is established at the INL as a testing environment to evaluate the security vulnerabilities of SCADA systems, energy management systems (EMS), and distributed control systems. It now supports multiple programs sponsored by the U.S. Department of Energy, the U.S. Department of Homeland Security, other government agencies, and private sector clients. This particular test plan applies to testing conducted on a SCADA/EMS provided by a vendor. Before performing detailed vulnerability testing of a SCADA/EMS, an as delivered baseline examination of the system is conducted, to establish a starting point for all-subsequent testing. The series of baseline tests document factory delivered defaults, system configuration, and potential configuration changes to aid in the development of a security plan for in depth vulnerability testing. The baseline test document is provided to the System Provider,a who evaluates the baseline report and provides recommendations to the system configuration to enhance the security profile of the baseline system. Vulnerability testing is then conducted at the SCADA Test Bed, which provides an in-depth security analysis of the Vendor’s system.b a. The term System Provider replaces the name of the company/organization providing the system being evaluated. This can be the system manufacturer, a system user, or a third party organization such as a government agency. b. The term Vendor (or Vendor’s) System replaces the name of the specific SCADA/EMS being tested.

James R. Davidson

2005-01-01T23:59:59.000Z

191

TRUEX Radiolysis Testing Using the INL Radiolysis Test Loop: FY-2012 Status Report  

SciTech Connect (OSTI)

The INL radiolysis test loop has been used to evaluate the affect of radiolytic degradation upon the efficacy of the strip section of the TRUEX flowsheet for the recovery of trivalent actinides and lanthanides from acidic solution. The nominal composition of the TRUEX solvent used in this study is 0.2 M CMPO and 1.4 M TBP dissolved in n-dodecane and the nominal composition of the TRUEX strip solution is 1.5 M lactic acid and 0.050 M diethylenetriaminepentaacetic acid. Gamma irradiation of a mixture of TRUEX process solvent and stripping solution in the test loop does not adversely impact flowsheet performance as measured by stripping americium ratios. The observed increase in americium stripping distribution ratios with increasing absorbed dose indicates the radiolytic production of organic soluble degradation compounds.

Dean R. Peterman; Lonnie G. Olson; Richard D. Tillotson; Rocklan G. McDowell; Jack D. Law

2012-09-01T23:59:59.000Z

192

Engineering report (conceptual design) PFP solution stabilization  

SciTech Connect (OSTI)

This Engineering Report (Conceptual Design) addresses remediation of the plutonium-bearing solutions currently in inventory at the Plutonium Finishing Plant (PFP). The recommendation from the Environmental Impact Statement (EIS) is that the solutions be treated thermally and stabilized as a solid for long term storage. For solutions which are not discardable, the baseline plan is to utilize a denitration process to stabilize the solutions prior to packaging for storage.

Witt, J.B.

1997-07-17T23:59:59.000Z

193

Clean Energy Solutions Center Services (Fact Sheet)  

SciTech Connect (OSTI)

The Clean Energy Solutions Center (Solutions Center) helps governments, advisors and analysts create policies and programs that advance the deployment of clean energy technologies. The Solutions Center partners with international organizations to provide online training, expert assistance, and technical resources on clean energy policy.

Not Available

2014-04-01T23:59:59.000Z

194

IBM Software Solution Brief Safeguarding the cloud  

E-Print Network [OSTI]

IBM Software Solution Brief Safeguarding the cloud with IBM Security solutions Maintain visibility and control with proven security solutions for public, private and hybrid clouds Highlights Address cloud internal and external users, data, applications and workloads as they move to and from the cloud Regain

195

Internship -Fall 2011 Search Solutions Digital Media  

E-Print Network [OSTI]

Internship - Fall 2011 Search Solutions Digital Media SSdigitalmedia.com About us: Search Solutions Search Solutions Digital Media 1500 N. Stephenson HWY Royal Oak, MI 48067 Amanda are a full service digital advertising agency. We build custom web packages to meet our clients' exact needs

Cinabro, David

196

SLUG TESTING IN WELLS WITH FINITE-THICKNESS SKIN  

SciTech Connect (OSTI)

We present an analysis of the slug test in a well surrounded by an annulus of altered material, which is treated as a skin of finite thickness. By assuming the skin has a thickness, the storage capacity of the altered material is included in the analysis. The problem is solved in the Laplace domain. The solution is found in terms of well-bore storage and the thickness, hydraulic conductivity, and specific storage of the skin. Type curves are generated by numerical inversion of the Laplace transform solution. We find that standard methods of analysis, involving a skin of infinitesimal thickness, are adequate for open-well or drill-stem tests. However, for pressurized tests the response may differ markedly from standard slug-test solutions.

Moench, A.F.; Hsieh

1985-01-22T23:59:59.000Z

197

Structural Testing: An Introduction Flow Graphs Path Testing Conclusions Path Testing  

E-Print Network [OSTI]

Structural Testing: An Introduction Flow Graphs Path Testing Conclusions Path Testing Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing, 2013 Mousavi: Path Testing #12;Structural Testing: An Introduction Flow Graphs Path Testing Conclusions Outline Structural

Mousavi, Mohammad

198

Structural Testing: An Introduction Flow Graphs Path Testing Conclusions Path Testing  

E-Print Network [OSTI]

Structural Testing: An Introduction Flow Graphs Path Testing Conclusions Path Testing Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing, 2012 Mousavi: Path Testing #12;Structural Testing: An Introduction Flow Graphs Path Testing Conclusions Outline Structural

Mousavi, Mohammad

199

Solar system tests of Ho?ava-Lifshitz gravity  

E-Print Network [OSTI]

Recently, a renormalizable gravity theory with higher spatial derivatives in four dimensions was proposed by Ho\\v{r}ava. The theory reduces to Einstein gravity with a non-vanishing cosmological constant in IR, but it has improved UV behaviors. The spherically symmetric black hole solutions for an arbitrary cosmological constant, which represent the generalization of the standard Schwarzschild-(A)dS solution, has also been obtained for the Ho\\v{r}ava-Lifshitz theory. The exact asymptotically flat Schwarzschild type solution of the gravitational field equations in Ho\\v{r}ava gravity contains a quadratic increasing term, as well as the square root of a fourth order polynomial in the radial coordinate, and it depends on one arbitrary integration constant. The IR modified Ho\\v{r}ava gravity seems to be consistent with the current observational data, but in order to test its viability more observational constraints are necessary. In the present paper we consider the possibility of observationally testing Ho\\v{r}ava gravity at the scale of the Solar System, by considering the classical tests of general relativity (perihelion precession of the planet Mercury, deflection of light by the Sun and the radar echo delay) for the spherically symmetric black hole solution of Ho\\v{r}ava-Lifshitz gravity. All these gravitational effects can be fully explained in the framework of the vacuum solution of the gravity. Moreover, the study of the classical general relativistic tests also constrain the free parameter of the solution.

Tiberiu Harko; Zoltan Kovács; Francisco S. N. Lobo

2010-10-28T23:59:59.000Z

200

Moving from software to solutions  

SciTech Connect (OSTI)

Like other industries, oil and gas companies are looking to computer-aided technologies to contribute to their bottom line. The question is, what can and should software vendors offer the oil and gas industry for them to achieve this goal? In order to answer this, the paper looks at the enablers of change that today's geoscience software vendors can exploit to meet these challenges, as well as at the future role of software vendors. The era of computer-aided exploration tools has somewhat changed. The oil and gas industry's concerns for cost-effectiveness demand a more holistic approach--geoscience software and services that optimize the reservoir's full life cycle. Recent advances in computing technologies and geoscience justify the oil and gas industry's expectations that software vendors deliver next-generation reservoir management solutions.

Weiss, E.

2000-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Solution synthesis of germanium nanocrystals  

SciTech Connect (OSTI)

A method for providing a route for the synthesis of a Ge(0) nanometer-sized material from. A Ge(II) precursor is dissolved in a ligand heated to a temperature, generally between approximately 100.degree. C. and 400.degree. C., sufficient to thermally reduce the Ge(II) to Ge(0), where the ligand is a compound that can bond to the surface of the germanium nanomaterials to subsequently prevent agglomeration of the nanomaterials. The ligand encapsulates the surface of the Ge(0) material to prevent agglomeration. The resulting solution is cooled for handling, with the cooling characteristics useful in controlling the size and size distribution of the Ge(0) materials. The characteristics of the Ge(II) precursor determine whether the Ge(0) materials that result will be nanocrystals or nanowires.

Gerung, Henry (Albuquerque, NM); Boyle, Timothy J. (Kensington, MD); Bunge, Scott D. (Cuyahoga Falls, OH)

2009-09-22T23:59:59.000Z

202

Regional Transmission Projects: Finding Solutions  

SciTech Connect (OSTI)

The Keystone Center convened and facilitated a year-long Dialogue on "Regional Transmission Projects: Finding Solutions" to develop recommendations that will help address the difficult and contentious issues related to expansions of regional electric transmission systems that are needed for reliable and economic transmission of power within and across regions. This effort brought together a cross-section of affected stakeholders and thought leaders to address the problem with the collective wisdom of their experience and interests. Transmission owners sat at the table with consumer advocates and environmental organizations. Representatives from regional transmission organizations exchanged ideas with state and federal regulators. Generation developers explored common interests with public power suppliers. Together, the Dialogue participants developed consensus solutions about how to begin unraveling some of the more intractable issues surrounding identification of need, allocation of costs, and reaching consensus on siting issues that can frustrate the development of regional transmission infrastructure. The recommendations fall into three broad categories: 1. Recommendations on appropriate institutional arrangements and processes for achieving regional consensus on the need for new or expanded transmission infrastructure 2. Recommendations on the process for siting of transmission lines 3. Recommendations on the tools needed to support regional planning, cost allocation, and siting efforts. List of Dialogue participants: List of Dialogue Participants: American Electric Power American Transmission Company American Wind Energy Association California ISO Calpine Corporation Cinergy Edison Electric Institute Environmental Defense Federal Energy Regulatory Commission Great River Energy International Transmission Company ISO-New England Iowa Public Utility Board Kanner & Associates Midwest ISO National Association of Regulatory Utility Commissioners National Association of State Utility Consumer Advocates National Grid Northeast Utilities PA Office of Consumer Advocates Pacific Gas & Electric Corporation Pennsylvania Public Utility Commission PJM Interconnection The Electricity Consumers Resource Council U.S. Department of Energy US Department of the Interior Van Ness Feldman Western Interstate Energy Board Wind on the Wires Wisconsin Public Service Commission Xcel Energy

The Keystone Center

2005-06-15T23:59:59.000Z

203

Characterising Vainshtein Solutions in Massive Gravity  

E-Print Network [OSTI]

We study static, spherically symmetric solutions in a recently proposed ghost-free model of non-linear massive gravity. We focus on a branch of solutions where the helicity-0 mode can be strongly coupled within certain radial regions, giving rise to the Vainshtein effect. We truncate the analysis to scales below the gravitational Compton wavelength, and consider the weak field limit for the gravitational potentials, while keeping all non-linearities of the helicity-0 mode. We determine analytically the number and properties of local solutions which exist asymptotically on large scales, and of local (inner) solutions which exist on small scales. We find two kinds of asymptotic solutions, one of which is asymptotically flat, while the other one is not, and also two types of inner solutions, one of which displays the Vainshtein mechanism, while the other exhibits a self-shielding behaviour of the gravitational field. We analyse in detail in which cases the solutions match in an intermediate region. The asymptotically flat solutions connect only to inner configurations displaying the Vainshtein mechanism, while the non asymptotically flat solutions can connect with both kinds of inner solutions. We show furthermore that there are some regions in the parameter space where global solutions do not exist, and characterise precisely in which regions of the phase space the Vainshtein mechanism takes place.

Fulvio Sbisa'; Gustavo Niz; Kazuya Koyama; Gianmassimo Tasinato

2014-06-17T23:59:59.000Z

204

Solderability test system  

DOE Patents [OSTI]

A new test method to quantify capillary flow solderability on a printed wiring board surface finish. The test is based on solder flow from a pad onto narrow strips or lines. A test procedure and video image analysis technique were developed for conducting the test and evaluating the data. Feasibility tests revealed that the wetted distance was sensitive to the ratio of pad radius to line width (l/r), solder volume, and flux predry time. 11 figs.

Yost, F.; Hosking, F.M.; Jellison, J.L.; Short, B.; Giversen, T.; Reed, J.R.

1998-10-27T23:59:59.000Z

205

Solderability test system  

DOE Patents [OSTI]

A new test method to quantify capillary flow solderability on a printed wiring board surface finish. The test is based on solder flow from a pad onto narrow strips or lines. A test procedure and video image analysis technique were developed for conducting the test and evaluating the data. Feasibility tests revealed that the wetted distance was sensitive to the ratio of pad radius to line width (l/r), solder volume, and flux predry time.

Yost, Fred (Cedar Crest, NM); Hosking, Floyd M. (Albuquerque, NM); Jellison, James L. (Albuquerque, NM); Short, Bruce (Beverly, MA); Giversen, Terri (Beverly, MA); Reed, Jimmy R. (Austin, TX)

1998-01-01T23:59:59.000Z

206

Robotic Efficiency Solutions for Ductwork  

E-Print Network [OSTI]

is possible. ? In practice, however, ducts leak more than they should. Measurements made by Lawrence Berkeley National Laboratory (LBNL) of commercial building duct systems found , on average, duct leakage exceeded the ASHRAE recommended leakage classes... by roughly a factor of 20. ? Standards in regards to duct leakage: ? Historically visual ? Moving towards required testing with maximum leakage allowed Duct Leakage ? 2 billion dollars in energy loss through leaky ductwork in commercial buildings...

Forrest, F.

2012-01-01T23:59:59.000Z

207

Concentrator E-F11 water test  

SciTech Connect (OSTI)

This document is the Process Test Report for performing operation testing with water of the modified E-F11 concentrator in PUREX on water. The test was performed to determine the effects of the following concentrator modifications; routing concentrator off-gasses via the PUREX air tunnel to the main stack, blanking of condenser cooling water, blanking of process condensate route to a crib, restricting flow to steam tube bundles, and routing of steam condensate to TK-F12. The test was successful. Concentrator boil-off rates of 6--7 gpm were achieved while the overheads exited the PUREX plant in vapor form. With minor recommended modifications, this process is recommended for use in processing PUREX deactivation flush solutions and other miscellaneous wastes accumulated during the completion of the deactivation project.

Ethington, P.R.

1994-02-25T23:59:59.000Z

208

Electrochemical Corrosion Testing of Neutron Absorber Materials  

SciTech Connect (OSTI)

This report summarizes the results of crevice-corrosion tests for six alloys in solutions representative of ionic compositions inside the Yucca Mountain waste package should a breech occur. The alloys in these tests are Neutronit A978a (ingot metallurgy, hot rolled), Neutrosorb Plus 304B4 Grade Ab (powder metallurgy, hot rolled), Neutrosorb Plus 304B5 Grade Ab (powder metallurgy, hot rolled), Neutrosorb Plus 304B6 Grade Ab (powder metallurgy, hot rolled), Ni-Cr-Mo-Gd alloy2 (ingot metallurgy, hot rolled), and Alloy 22 (ingot metallurgy, hot rolled).

Tedd Lister; Ron Mizia; Arnold Erickson; Tammy Trowbridge

2007-05-01T23:59:59.000Z

209

Check for peroxides every 6 months. opened test 1 test 2 test 3  

E-Print Network [OSTI]

Check for peroxides every 6 months. opened test 1 test 2 test 3 date initials Check for peroxides every 6 months. opened test 1 test 2 test 3 date initials Check for peroxides every 6 months. Test strips can be obtained from EH&S, 5-8200 opened test 1 test 2 test 3 date initials Check for peroxides

Pawlowski, Wojtek

210

Self limiting features of accidental criticality in a solution system  

SciTech Connect (OSTI)

Experience with the SHEBA solution critical assembly during validation testing of accidental criticality alarm detectors provided several insights into the character of potential accidental excursions. Two observations were of particular interest. First, it is nearly impossible to maintain a solution system, particularly one employing low-enrichment material, in a constant state. If super-critical, the system will heat up, expand (or form bubbles), return to a sub-critical state, and shut down of its own accord without going into short period oscillations. Second, a very slow change in the system could produce a long ''pulse'' resulting in lengthy exposures, a high dose, but a low dose rate. The experiments dramatically contradicted the popular contention that accidental criticality is characterized by a blue flash, a clap of thunder, and violet expulsion of material. 5 refs., 3 figs., 4 tabs.

Malenfant, R.E.

1988-01-01T23:59:59.000Z

211

Automatic Test Factoring for Java  

E-Print Network [OSTI]

Test factoring creates fast, focused unit tests from slow system-widetests; each new unit test exercises only a subset of the functionalityexercised by the system test. Augmenting a test suite with factoredunit tests ...

Saff, David

2005-06-08T23:59:59.000Z

212

Manufactured solutions for the three-dimensional Euler equations with relevance to Inertial Confinement Fusion  

SciTech Connect (OSTI)

We present a set of manufactured solutions for the three-dimensional (3D) Euler equations. The purpose of these solutions is to allow for code verification against true 3D flows with physical relevance, as opposed to 3D simulations of lower-dimensional problems or manufactured solutions that lack physical relevance. Of particular interest are solutions with relevance to Inertial Confinement Fusion (ICF) capsules. While ICF capsules are designed for spherical symmetry, they are hypothesized to become highly 3D at late time due to phenomena such as Rayleigh–Taylor instability, drive asymmetry, and vortex decay. ICF capsules also involve highly nonlinear coupling between the fluid dynamics and other physics, such as radiation transport and thermonuclear fusion. The manufactured solutions we present are specifically designed to test the terms and couplings in the Euler equations that are relevant to these phenomena. Example numerical results generated with a 3D Finite Element hydrodynamics code are presented, including mesh convergence studies.

Waltz, J., E-mail: jwaltz@lanl.gov [Computational Physics Division, Los Alamos National Laboratory, Los Alamos, NM (United States); Canfield, T.R. [Theoretical Division, Los Alamos National Laboratory, Los Alamos, NM (United States); Morgan, N.R. [Computational Physics Division, Los Alamos National Laboratory, Los Alamos, NM (United States); Risinger, L.D.; Wohlbier, J.G. [Computational and Computer Sciences Division, Los Alamos National Laboratory, Los Alamos, NM (United States)

2014-06-15T23:59:59.000Z

213

Weak-Field Spherically Symmetric Solutions in $f(T)$ gravity  

E-Print Network [OSTI]

We study weak-field solutions having spherical symmetry in $f(T)$ gravity; to this end, we solve the field equations for a non diagonal tetrad, starting from Lagrangian in the form $f(T)=T+\\alpha T^{n}$, where $\\alpha$ is a small constant, parameterizing the departure of the theory from GR. We show that the classical spherically symmetric solutions of GR, i.e. the Schwarzschild and Schwarzschild-de Sitter solutions, are perturbed by terms in the form $\\propto r^{2-2n}$ and discuss the impact of these perturbations in observational tests.

Ruggiero, Matteo Luca

2015-01-01T23:59:59.000Z

214

Animal Health Diagnostic Center Test and Fee Schedule Test Name Test Fee Discipline Test Days Lag** Samples Container Coolant Comments  

E-Print Network [OSTI]

Animal Health Diagnostic Center Test and Fee Schedule Test Name Test Fee Discipline Test Days Lag** Samples Container Coolant Comments Feline Tests Feline Tests Acid Fast Stain (for bacteria) M-F 1-2 days 1 Tests, Equine Cushings Tests , Feline Adrenal Function Tests, or Appendix C. Endocrinology22.00 ACTH

Keinan, Alon

215

Sandia National Laboratories: Mechanical Testing  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

EnergyNuclear Energy Systems Laboratory (NESL) Brayton LabMechanical Testing Mechanical Testing Mechanical Testing Overview Mechanical 1-2 (2008). Standard Test Methods for...

216

New knotted solutions of Maxwell's equations  

E-Print Network [OSTI]

In this note we have further developed the study of topologically non-trivial solutions of vacuum electrodynamics. We have discovered a novel method of generating such solutions by applying conformal transformations with complex parameters on known solutions expressed in terms of Bateman's variables. This has enabled us to get a wide class of solutions from the basic configuration like constant electromagnetic fields and plane-waves. We have introduced a covariant formulation of the Bateman's construction and discussed the conserved charges associated with the conformal group as well as a set of four types of conserved helicities. We have also given a formulation in terms of quaternions. This led to a simple map between the electromagnetic knotted and linked solutions into flat connections of $SU(2)$ gauge theory. We have computed the corresponding CS charge in a class of solutions and it takes integer values.

Hoyos, Carlos; Sonnenschein, Jacob

2015-01-01T23:59:59.000Z

217

Corrosion property of 9Cr-ODS steel in nitric acid solution for spent nuclear fuel reprocessing  

SciTech Connect (OSTI)

Corrosion tests of oxide dispersion strengthened with 9% Cr (9Cr-ODS) steel, which is one of the desirable materials for cladding tube of sodium-cooled fast reactors, in pure nitric acid solution, spent FBR fuel solution, and its simulated solution were performed to understand the corrosion behavior in a spent nuclear fuel reprocessing. In this study, the 9Cr-ODS steel with lower effective chromium content was evaluated to understand the corrosion behavior conservatively. As results, the tube-type specimens of the 9Cr-ODS steels suffered severe weight loss owing to active dissolution at the beginning of the immersion test in pure nitric acid solution in the range from 1 to 3.5 M. In contrast, the weight loss was decreased and they showed a stable corrosion in the higher nitric acid concentration, the dissolved FBR fuel solution, and its simulated solution by passivation. The corrosion rates of the 9Cr-ODS steel in the dissolved FBR fuel solution and its simulated solution were 1-2 mm/y and showed good agreement with each other. The passivation was caused by the shift of corrosion potential to noble side owing to increase in nitric acid concentration or oxidative ions in the dissolved FBR fuel solution and the simulated spent fuel solution. (authors)

Takeuchi, M.; Koizumi, T. [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan); Inoue, M.; Koyama, S.I. [Japan Atomic Energy Agency, Oarai-machi, Higashi-ibaraki-gun, Ibaraki 311-1393 (Japan)

2013-07-01T23:59:59.000Z

218

I/O Test  

E-Print Network [OSTI]

IO TEST is intended as a hardware testing and debugging aid for use with the PDP-6 and its associated input multiplexer (analog to digital converter) and output multiplexer (digital to analog converter). While all characters ...

Beeler, Michael

1967-10-01T23:59:59.000Z

219

Robinson-Trautman solution with scalar hair  

E-Print Network [OSTI]

Explicit Robinson-Trautman solution with minimally coupled free scalar field is derived and analyzed. It is shown that this solution contains curvature singularity which is initially naked but later the horizon envelopes it. We use quasilocal horizon definition and prove its existence in later retarded times using sub- and supersolution method combined with growth estimates. We show that the solution is generally of algebraic type II but reduces to type D in spherical symmetry.

T. Tahamtan; O. Svitek

2015-03-31T23:59:59.000Z

220

Robinson-Trautman solution with scalar hair  

E-Print Network [OSTI]

Explicit Robinson-Trautman solution with minimally coupled free scalar field is derived and analyzed. It is shown that this solution contains curvature singularity which is initially naked but later the horizon envelopes it. We use quasilocal horizon definition and prove its existence in later retarded times using sub- and supersolution method combined with growth estimates. We show that the solution is generally of algebraic type II but reduces to type D in spherical symmetry.

Tahamtan, T

2015-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Articles about Testing  

Broader source: Energy.gov [DOE]

Stories about testing facilities, capabilities, and certification featured by the U.S. Department of Energy (DOE) Wind Program.

222

Coaxial test fixture  

DOE Patents [OSTI]

This invention pertains to arrangements for performing electrical tests on contact material samples, and in particular for testing contact material test samples in an evacuated environment under high current loads. Frequently, it is desirable in developing high-current separable contact material, to have at least a preliminary analysis of selected candidate conductor materials. Testing of material samples will hopefully identify materials unsuitable for high current electrical contact without requiring incorporation of the materials into a completed and oftentimes complex structure.

Praeg, W.F.

1984-03-30T23:59:59.000Z

223

AGCO Biomass Solutions: Biomass 2014 Presentation  

Broader source: Energy.gov [DOE]

Plenary IV: Advances in Bioenergy Feedstocks—From Field to Fuel AGCO Biomass Solutions: Biomass 2014 Presentation Glenn Farris, Marketing Manager Biomass, AGCO Corporation

224

Engineered Solutions: Order (2010-CE-2112)  

Broader source: Energy.gov [DOE]

DOE issued an Order after entering into a Compromise Agreement with Engineered Solutions, Inc. to resolve a case involving the failure to certify dehumidifier basic model SD109.

225

Engineered Solutions: Proposed Penalty (2010-CE-2112)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that Engineered Solutions, Inc. failed to certify a dehumidifier as compliant with the applicable energy conservation standards.

226

Black Hole Solutions in $R^2$ Gravity  

E-Print Network [OSTI]

We find static spherically symmetric solutions of scale invariant $R^2$ gravity. The latter has been shown to be equivalent to General Relativity with a positive cosmological constant and a scalar mode. Therefore, one expects that solutions of the $R^2$ theory will be identical to that of Einstein theory. Indeed, we find that the solutions of $R^2$ gravity are in one-to-one correspondence with solutions of General Relativity in the case of non-vanishing Ricci scalar. However, scalar-flat $R=0$ solutions are global minima of the $R^2$ action and they cannot in general be mapped to solutions of the Einstein theory. As we will discuss, the $R=0$ solutions arise in Einstein gravity as solutions in the tensionless, strong coupling limit $M_P\\rightarrow 0$. As a further result, there is no corresponding Birkhoff theorem and the Schwarzschild black hole is by no means unique in this framework. In fact, $R^2$ gravity has a rich structure of vacuum static spherically symmetric solutions partially uncovered here. We al...

Kehagias, Alex; Lust, Dieter; Riotto, Antonio

2015-01-01T23:59:59.000Z

227

Optimization Online - Solution Analysis for the Pseudomonotone ...  

E-Print Network [OSTI]

Nov 18, 2014 ... Solution Analysis for the Pseudomonotone Second-order Cone Linear Complementarity Problem. Yang Wei Hong(whyang ***at*** ...

Yang Wei Hong

2014-11-18T23:59:59.000Z

228

NFWF Environmental Solutions for Communities Grant  

Broader source: Energy.gov [DOE]

Wells Fargo and the National Fish and Wildlife Foundation (NFWF) are accepting applications for approximately $2.5 million in Environmental Solutions for Communities grants.

229

El Paso Electric Company- Residential Solutions Program  

Broader source: Energy.gov [DOE]

'''The El Paso Electric Residential Solutions Program funding has been expended in Texas for 2012. New funding will be available January 1, 2013. '''

230

Home Energy Solutions for Existing Homes  

Broader source: Energy.gov [DOE]

Energy Trust of Oregon offers a variety of incentives and services through their Home Energy Solutions program. All equipment eligible for incentives needs to meet the efficiency requirements...

231

Independent Activity Report, Washington River Protection Solutions...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Solutions, LLC Industrial Hygiene Program Strategy and Implementation of the Hanford Concerns Council Recommendations HIAR-ORP-2011-10-26 This Independent Activity...

232

TVA- Energy Right Solutions for Business  

Broader source: Energy.gov [DOE]

TVA offers the Energy Right Solutions Program to commercial and industrial facilities. In addition to prescriptive rebates for lighting, motors, HVAC, and kitchen equipment, administrators take a...

233

TVA- Energy Right Solutions for Business (Virginia)  

Broader source: Energy.gov [DOE]

The Tennessee Valley Authority (TVA) offers the Energy Right Solutions Program for commercial and industrial facilities. Prescriptive rebates are available for lighting, motors, HVAC, and kitchen...

234

TVA- Energy Right Solutions for Business (Georgia)  

Broader source: Energy.gov [DOE]

TVA offers the Energy Right Solutions Program to commercial and industrial facilities. In addition to prescriptive rebates for lighting, motors, HVAC, and kitchen equipment, administrators take a...

235

Advanced Combustion Concepts - Enabling Systems and Solutions...  

Broader source: Energy.gov (indexed) [DOE]

Evaluation Meeting ace066yilmaz2013o.pdf More Documents & Publications Advanced Combustion Concepts - Enabling Systems and Solutions (ACCESS) for High Efficiency Light Duty...

236

Gas Test Loop Booster Fuel Hydraulic Testing  

SciTech Connect (OSTI)

The Gas Test Loop (GTL) project is for the design of an adaptation to the Advanced Test Reactor (ATR) to create a fast-flux test space where fuels and materials for advanced reactor concepts can undergo irradiation testing. Incident to that design, it was found necessary to make use of special booster fuel to enhance the neutron flux in the reactor lobe in which the Gas Test Loop will be installed. Because the booster fuel is of a different composition and configuration from standard ATR fuel, it is necessary to qualify the booster fuel for use in the ATR. Part of that qualification is the determination that required thermal hydraulic criteria will be met under routine operation and under selected accident scenarios. The Hydraulic Testing task in the GTL project facilitates that determination by measuring flow coefficients (pressure drops) over various regions of the booster fuel over a range of primary coolant flow rates. A high-fidelity model of the NW lobe of the ATR with associated flow baffle, in-pile-tube, and below-core flow channels was designed, constructed and located in the Idaho State University Thermal Fluids Laboratory. A circulation loop was designed and constructed by the university to provide reactor-relevant water flow rates to the test system. Models of the four booster fuel elements required for GTL operation were fabricated from aluminum (no uranium or means of heating) and placed in the flow channel. One of these was instrumented with Pitot tubes to measure flow velocities in the channels between the three booster fuel plates and between the innermost and outermost plates and the side walls of the flow annulus. Flow coefficients in the range of 4 to 6.5 were determined from the measurements made for the upper and middle parts of the booster fuel elements. The flow coefficient for the lower end of the booster fuel and the sub-core flow channel was lower at 2.3.

Gas Test Loop Hydraulic Testing Staff

2006-09-01T23:59:59.000Z

237

Soil Testing and Research  

E-Print Network [OSTI]

Soil Testing and Research Analytical Laboratory Copyright © 2014 University of Minnesota Soil Testing and Research Analytical Laboratory Department of Soil, Water and Climate College of Food payable to the University of Minnesota We also accept the following credit cards: Soil Testing

Ciocan-Fontanine, Ionut

238

SMVCIR Dimensionality Test  

E-Print Network [OSTI]

the dimensionality test and testing it. The dimensionality test is based on the singular values of the kernel of the spanning set of the vector space. The asymptotic distribution of the spanning set is found by using the central limit theorem, delta method...

Lindsey, Charles D.

2011-08-08T23:59:59.000Z

239

Systems and methods for laser assisted sample transfer to solution for chemical analysis  

SciTech Connect (OSTI)

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

Van Berkel, Gary J.; Kertesz, Vilmos; Ovchinnikova, Olga S.

2014-06-03T23:59:59.000Z

240

Systems and methods for laser assisted sample transfer to solution for chemical analysis  

DOE Patents [OSTI]

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

Van Berkel, Gary J; Kertesz, Vilmos; Ovchinnikova, Olga S

2013-08-27T23:59:59.000Z

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Technical solutions to nonproliferation challenges  

SciTech Connect (OSTI)

The threat of nuclear terrorism is real and poses a significant challenge to both U.S. and global security. For terrorists, the challenge is not so much the actual design of an improvised nuclear device (IND) but more the acquisition of the special nuclear material (SNM), either highly enriched uranium (HEU) or plutonium, to make the fission weapon. This paper provides two examples of technical solutions that were developed in support of the nonproliferation objective of reducing the opportunity for acquisition of HEU. The first example reviews technologies used to monitor centrifuge enrichment plants to determine if there is any diversion of uranium materials or misuse of facilities to produce undeclared product. The discussion begins with a brief overview of the basics of uranium processing and enrichment. The role of the International Atomic Energy Agency (IAEA), its safeguard objectives and how the technology evolved to meet those objectives will be described. The second example focuses on technologies developed and deployed to monitor the blend down of 500 metric tons of HEU from Russia's dismantled nuclear weapons to reactor fuel or low enriched uranium (LEU) under the U.S.-Russia HEU Purchase Agreement. This reactor fuel was then purchased by U.S. fuel fabricators and provided about half the fuel for the domestic power reactors. The Department of Energy established the HEU Transparency Program to provide confidence that weapons usable HEU was being blended down and thus removed from any potential theft scenario. Two measurement technologies, an enrichment meter and a flow monitor, were combined into an automated blend down monitoring system (BDMS) and were deployed to four sites in Russia to provide 24/7 monitoring of the blend down. Data was downloaded and analyzed periodically by inspectors to provide the assurances required.

Satkowiak, Lawrence [Director, Nonproliferation, Safeguards and Security Programs, Oak Ridge National Laboratory, Oak Ridge, Tennessee (United States)

2014-05-09T23:59:59.000Z

242

Decontamination by cleaning with fluorocarbon surfactant solutions  

SciTech Connect (OSTI)

In the nuclear industry, facilities and their components inevitably become contaminated with radioactive materials. This report documents the application of a novel particle-removal process developed by Entropic Systems, Inc. (ESI), to decontaminate critical instruments and parts that are contaminated with small radioactive particles that adhere to equipment surfaces. The tests were performed as a cooperative effort between ESI and the Chemical Technology Division of the Oak Ridge National Laboratory (ORNL). ESI developed a new, environmentally compatible process to remove small particles from solid surfaces that is more effective than spraying or sonicating with CFC-113. This process uses inert perfluorinated liquids as working media; the liquids have zero ozone-depleting potential, are nontoxic and nonflammnable, and are generally recognized as nonhazardous materials. In the ESI process, parts to be cleaned are first sprayed or sonicated with a dilute solution of a high-molecular-weight fluorocarbon surfactant in an inert perfluorinated liquid to effect particle removal. The parts are then rinsed with the perfluorinated liquid to remove the fluorocarbon surfactant applied in the first step, and the residual rinse liquid is then evaporated from the parts into an air or nitrogen stream from which it is recovered. Nuclear contamination is inherently a surface phenomenon. The presence of radioactive particles is responsible for all ``smearable`` contamination and, if the radioactive particles are small enough, for some of the fixed contamination. Because radioactivity does not influence the physical chemistry of particle adhesion, the ESI process should be just as effective in removing radioactive particles as it is in removing nonradioactive particles.

Kaiser, R. [Entropic Systems, Inc., Winchester, MA (United States); Benson, C.E.; Meyers, E.S. [Oak Ridge National Lab., TN (United States); Vaughen, V.C.A. [Chemical Engineering and Safety Consulting Services, Knoxville, TN (United States)

1994-02-01T23:59:59.000Z

243

Texas A&M University Counseling and Testing Center data processing system  

E-Print Network [OSTI]

University Counseling and Testing Center. The system does not attempt to be the solution to the general question of reporting test results. The ma)ority of the techniques and procedures designed to solve the Counseling and Testing Center's specific... applicable to policies, procedures, and techniques that appear to be the most effective in specific circumstances. & 3 Fundamental Research in Administration, p. 41. The Counseling and Testing Center is required to report test results and to prepare...

Burwell, Edward Marshall

1964-01-01T23:59:59.000Z

244

Pendulum detector testing device  

DOE Patents [OSTI]

A detector testing device which provides consistent, cost-effective, repeatable results. The testing device is primarily constructed of PVC plastic and other non-metallic materials. Sensitivity of a walk-through detector system can be checked by: 1) providing a standard test object simulating the mass, size and material content of a weapon or other contraband, 2) suspending the test object in successive positions, such as head, waist and ankle levels, simulating where the contraband might be concealed on a person walking through the detector system; and 3) swinging the suspended object through each of the positions, while operating the detector system and observing its response. The test object is retained in a holder in which the orientation of the test device or target can be readily changed, to properly complete the testing requirements.

Gonsalves, John M. (Modesto, CA)

1997-01-01T23:59:59.000Z

245

Pendulum detector testing device  

DOE Patents [OSTI]

A detector testing device is described which provides consistent, cost-effective, repeatable results. The testing device is primarily constructed of PVC plastic and other non-metallic materials. Sensitivity of a walk-through detector system can be checked by: (1) providing a standard test object simulating the mass, size and material content of a weapon or other contraband, (2) suspending the test object in successive positions, such as head, waist and ankle levels, simulating where the contraband might be concealed on a person walking through the detector system; and (3) swinging the suspended object through each of the positions, while operating the detector system and observing its response. The test object is retained in a holder in which the orientation of the test device or target can be readily changed, to properly complete the testing requirements. 5 figs.

Gonsalves, J.M.

1997-09-30T23:59:59.000Z

246

Energy Technology Solutions: Public-Private Partnerships Transforming...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Solutions: Public-Private Partnerships Transforming Industry, November 2010 Energy Technology Solutions: Public-Private Partnerships Transforming Industry, November 2010...

247

Slug Test Data Analysis in Reservoirs with Double Porosity Behaviour  

SciTech Connect (OSTI)

Pressure analysis for a slug test which corresponds to the flow period of a Drill Stem test is extended to wells in reservoirs with double-porosity behaviour. Solutions are obtained for either pseudo-steady state or transient interporosity flow. The distinctive specific features of both solutions are identified. Results presented are applicable to both naturally-fractured and layered reservoirs with the more permeable layer connecting to the wellbore. Type curves based on the pseudo-steady or transient interporosity flow are presented. These type curves are similar to the existing homogenous single layer type curve with addition of interporosity flow lines indicating double-porosity behaviour.

Mateen, Khalid; Ramey, Henry J. Jr.

1983-12-15T23:59:59.000Z

248

Exercise Session 7 (with solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 7 (with solutions) Alessandro Abate a.abate@tudelft.nl Aleksandar Haber a Session 7 ­ sc4026 #12;A. Abate, A. Haber Solution to state space models Find the output response Sem. Q1 ­ Exercise Session 7 ­ sc4026 1 #12;A. Abate, A. Haber The output is Y (t) = CX(t) + DU

Abate, Alessandro

249

Exercise Session 7 (with solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 7 (with solutions) Alessandro Abate a.abate@tudelft.nl Marco Forgione m Session 7 ­ sc4026 #12;A. Abate, M. Forgione Solution to state space models Find the output response Sem. Q1 ­ Exercise Session 7 ­ sc4026 1 #12;A. Abate, M. Forgione The output is Y (t) = CX(t) + DU

Abate, Alessandro

250

The general double-dust solution  

E-Print Network [OSTI]

The gravitational field of two identical rotating and counter-moving dust beams is found in full generality. The solution depends on an arbitrary function and a parameter. Some of its properties are studied. Previous particular solutions are derived as subcases.

B. V. Ivanov

2003-02-04T23:59:59.000Z

251

Decomposing Linear Programs for Parallel Solution?  

E-Print Network [OSTI]

Decomposing Linear Programs for Parallel Solution? Ali P nar, Umit V. Catalyurek, Cevdet Aykanat in the solution of Linear Programming (LP) problems with block angular constraint matrices has been exploited industrial applications and the advent of powerful computers have in- creased the users' ability to formulate

�atalyürek, �mit V.

252

Decomposing Linear Programs for Parallel Solution ?  

E-Print Network [OSTI]

Decomposing Linear Programs for Parallel Solution ? Ali Pinar, ¨ Umit V. C¸ ataly¨urek, Cevdet in the solution of Linear Programming (LP) problems with block angular constraint matrices has been exploited with successful industrial applications and the advent of powerful computers have in­ creased the users' ability

�atalyürek, �mit V.

253

Kampung Capacity Local Solutions for Sustainable  

E-Print Network [OSTI]

Kampung Capacity Local Solutions for Sustainable Rural Energy in the Baram River Basin, Sarawak for the river basin. Keywords: South East Asia, Malaysia, Rural Energy Access, Local Solutions #12;RAEL Report, Malaysia Rebekah Shirley Daniel Kammen University of California ­ Berkeley Renewable and Appropriate Energy

Kammen, Daniel M.

254

DWPF Recycle Evaporator Simulant Tests  

SciTech Connect (OSTI)

Testing was performed to determine the feasibility and processing characteristics of an evaporation process to reduce the volume of the recycle stream from the Defense Waste Processing Facility (DWPF). The concentrated recycle would be returned to DWPF while the overhead condensate would be transferred to the Effluent Treatment Plant. Various blends of evaporator feed were tested using simulants developed from characterization of actual recycle streams from DWPF and input from DWPF-Engineering. The simulated feed was evaporated in laboratory scale apparatus to target a 30X volume reduction. Condensate and concentrate samples from each run were analyzed and the process characteristics (foaming, scaling, etc) were visually monitored during each run. The following conclusions were made from the testing: Concentration of the ''typical'' recycle stream in DWPF by 30X was feasible. The addition of DWTT recycle streams to the typical recycle stream raises the solids content of the evaporator feed considerably and lowers the amount of concentration that can be achieved. Foaming was noted during all evaporation tests and must be addressed prior to operation of the full-scale evaporator. Tests were conducted that identified Dow Corning 2210 as an antifoam candidate that warrants further evaluation. The condensate has the potential to exceed the ETP WAC for mercury, silicon, and TOC. Controlling the amount of equipment decontamination recycle in the evaporator blend would help meet the TOC limits. The evaporator condensate will be saturated with mercury and elemental mercury will collect in the evaporator condensate collection vessel. No scaling on heating surfaces was noted during the tests, but splatter onto the walls of the evaporation vessels led to a buildup of solids. These solids were difficult to remove with 2M nitric acid. Precipitation of solids was not noted during the testing. Some of the aluminum present in the recycle streams was converted from gibbsite to aluminum oxide during the evaporation process. The following recommendations were made: Recycle from the DWTT should be metered in slowly to the ''typical'' recycle streams to avoid spikes in solids content to allow consistent processing and avoid process upsets. Additional studies should be conducted to determine acceptable volume ratios for the HEME dissolution and decontamination solutions in the evaporator feed. Dow Corning 2210 antifoam should be evaluated for use to control foaming. Additional tests are required to determine the concentration of antifoam required to prevent foaming during startup, the frequency of antifoam additions required to control foaming during steady state processing, and the ability of the antifoam to control foam over a range of potential feed compositions. This evaluation should also include evaluation of the degradation of the antifoam and impact on the silicon and TOC content of the condensate. The caustic HEME dissolution recycle stream should be neutralized to at least pH of 7 prior to blending with the acidic recycle streams. Dow Corning 2210 should be used during the evaporation testing using the radioactive recycle samples received from DWPF. Evaluation of additional antifoam candidates should be conducted as a backup for Dow Corning 2210. A camera and/or foam detection instrument should be included in the evaporator design to allow monitoring of the foaming behavior during operation. The potential for foam formation and high solids content should be considered during the design of the evaporator vessel.

Stone, M

2005-04-05T23:59:59.000Z

255

Advanced Technology Vehicle Testing  

SciTech Connect (OSTI)

The light-duty vehicle transportation sector in the United States depends heavily on imported petroleum as a transportation fuel. The Department of Energy’s Advanced Vehicle Testing Activity (AVTA) is testing advanced technology vehicles to help reduce this dependency, which would contribute to the economic stability and homeland security of the United States. These advanced technology test vehicles include internal combustion engine vehicles operating on 100% hydrogen (H2) and H2CNG (compressed natural gas) blended fuels, hybrid electric vehicles, neighborhood electric vehicles, urban electric vehicles, and electric ground support vehicles. The AVTA tests and evaluates these vehicles with closed track and dynamometer testing methods (baseline performance testing) and accelerated reliability testing methods (accumulating lifecycle vehicle miles and operational knowledge within 1 to 1.5 years), and in normal fleet environments. The Arizona Public Service Alternative Fuel Pilot Plant and H2-fueled vehicles are demonstrating the feasibility of using H2 as a transportation fuel. Hybrid, neighborhood, and urban electric test vehicles are demonstrating successful applications of electric drive vehicles in various fleet missions. The AVTA is also developing electric ground support equipment (GSE) test procedures, and GSE testing will start during the fall of 2003. All of these activities are intended to support U.S. energy independence. The Idaho National Engineering and Environmental Laboratory manages these activities for the AVTA.

James Francfort

2003-11-01T23:59:59.000Z

256

Compatibility of Einstein minimally coupled self interacting scalar field theory with the solar system tests of gravity  

E-Print Network [OSTI]

We examine the compatibility of the Einstein minimally coupled self-interacting scalar field theory with the local tests of gravity. We find that apart from the trivial case of the Schwarzschild-de Sitter solution with constant scalar field the theory does not admit any other static solution, which is consistent with the solar system tests of gravity.

A. Bhadra

2008-10-06T23:59:59.000Z

257

Training & Technology Solutions Queens College ~ Office of Converging Technologies ~ Training & Technology Solutions  

E-Print Network [OSTI]

Training & Technology Solutions Queens College ~ Office of Converging Technologies ~ Training & Technology Solutions 718-997-4875 ~ training@qc.cuny.edu ~ I-Bldg 214 DegreeWorks 4.09 Student Manual Degree is the same account you used when applying to Queens College. #12;Training & Technology Solutions Queens

Johnson Jr.,, Ray

258

Training & Technology Solutions Queens College ~ Office of Converging Technologies ~ Training & Technology Solutions  

E-Print Network [OSTI]

Training & Technology Solutions Queens College ~ Office of Converging Technologies ~ Training & Technology Solutions 718-997-4875 ~ training@qc.cuny.edu ~ I-Bldg 214 How To Navigate the Finance Section the payment history) · Pending Financial Aid #12;Training & Technology Solutions Queens College ~ Office

Johnson Jr.,, Ray

259

Training & Technology Solutions Queens College ~ Office of Converging Technologies ~ Training & Technology Solutions  

E-Print Network [OSTI]

Training & Technology Solutions Queens College ~ Office of Converging Technologies ~ Training & Technology Solutions 718-997-4875 ~ training@qc.cuny.edu ~ I-Bldg 214 CUNYfirst Faculty Center Navigation;Training & Technology Solutions Queens College ~ Office of Converging Technologies ~ Training & Technology

Johnson Jr.,, Ray

260

Finite State Machines Testing problems Conformance Testing Machine Identification FSM-Based Testing  

E-Print Network [OSTI]

Finite State Machines Testing problems Conformance Testing Machine Identification FSM-Based Testing Mousavi: FSM-Based Testing Part II #12;Finite State Machines Testing problems Conformance Testing Machine Identification Outline Finite State Machines Testing problems Conformance Testing Machine Identification Mousavi

Mousavi, Mohammad

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

The production characteristics of a solution gas-drive reservoir as measured on a centrifugal model  

E-Print Network [OSTI]

Mixtures and Cetus Oil - Natural Gas Mixtures Reservoir Pez&ormance Characteristics for Test Number 17 Through Well Number Three with Fluid Number One Reservoir Perfozmanco Characteristics for Test Number 32 Through Well Number One with Fluid Number.... recoveries were obtained vhen the fluid was produced through a central weAl than when production was through a well in the extreme end of the reservoir. Lower viscosity gave substantially higher recoveries~ but larger amounts of gas in solution had...

Goodwin, Robert Jennings

1955-01-01T23:59:59.000Z

262

Dark energy perturbations and a possible solution to the coincidence problem  

E-Print Network [OSTI]

We analyze some generic properties of the dark energy (DE) perturbations, in the case of a self-conserved DE fluid. We also apply a simple test (the "F-test") to compare a model to the data on large scale structure (LSS) under the assumption of negligible DE perturbations. We exemplify our discussions by means of the LXCDM model, showing that it provides a viable solution to the cosmological coincidence problem.

Javier Grande; Ana Pelinson; Joan Sola

2009-05-04T23:59:59.000Z

263

Advanced Technology Vehicle Testing  

SciTech Connect (OSTI)

The goal of the U.S. Department of Energy's Advanced Vehicle Testing Activity (AVTA) is to increase the body of knowledge as well as the awareness and acceptance of electric drive and other advanced technology vehicles (ATV). The AVTA accomplishes this goal by testing ATVs on test tracks and dynamometers (Baseline Performance testing), as well as in real-world applications (Fleet and Accelerated Reliability testing and public demonstrations). This enables the AVTA to provide Federal and private fleet managers, as well as other potential ATV users, with accurate and unbiased information on vehicle performance and infrastructure needs so they can make informed decisions about acquiring and operating ATVs. The ATVs currently in testing include vehicles that burn gaseous hydrogen (H2) fuel and hydrogen/CNG (H/CNG) blended fuels in internal combustion engines (ICE), and hybrid electric (HEV), urban electric, and neighborhood electric vehicles. The AVTA is part of DOE's FreedomCAR and Vehicle Technologies Program.

James Francfort

2004-06-01T23:59:59.000Z

264

Improved parallel solution techniques for the integral transport matrix method  

SciTech Connect (OSTI)

Alternative solution strategies to the parallel block Jacobi (PBJ) method for the solution of the global problem with the integral transport matrix method operators have been designed and tested. The most straightforward improvement to the Jacobi iterative method is the Gauss-Seidel alternative. The parallel red-black Gauss-Seidel (PGS) algorithm can improve on the number of iterations and reduce work per iteration by applying an alternating red-black color-set to the subdomains and assigning multiple sub-domains per processor. A parallel GMRES(m) method was implemented as an alternative to stationary iterations. Computational results show that the PGS method can improve on the PBJ method execution by up to {approx}50% when eight sub-domains per processor are used. However, compared to traditional source iterations with diffusion synthetic acceleration, it is still approximately an order of magnitude slower. The best-performing case are opticaUy thick because sub-domains decouple, yielding faster convergence. Further tests revealed that 64 sub-domains per processor was the best performing level of sub-domain division. An acceleration technique that improves the convergence rate would greatly improve the ITMM. The GMRES(m) method with a diagonal block preconditioner consumes approximately the same time as the PBJ solver but could be improved by an as yet undeveloped, more efficient preconditioner.

Zerr, Robert J [Los Alamos National Laboratory; Azmy, Yousry Y [NORTH CAROLINA STATE UNIV.

2010-11-23T23:59:59.000Z

265

Inflow performance relationships for solution-gas-drive reservoirs  

SciTech Connect (OSTI)

In this theoretical study, a numerical model was used to examine the influence of pressure level and skin factor on the inflow performance relationships (IPR's) of wells producing under solution-gas-drive systems. Examination of the synthetic deliverability curves suggests that the exponent of the deliverability curve is a function of time and that the exponent is usually greater than unity. The implication of this observation to field data is discussed. The accuracy of procedures given in the literature to predict oilwell deliverabilities is also examined. It is shown that these methods can be used to predict future performance provided that the exponent of the deliverability curve is known and that extrapolations over large time ranges are avoided. If single-point tests are used to predict future performance (such tests assume that the exponent of the deliverability curve is constant), then errors in predictions will be minimized. Although relative permeability and fluid property data are required, the Muskat material-balance equation and the assumption that GOR is independent of distance can be used to predict future production rates. This method avoids problems associated with other methods in the literature and always yields reliable results. New methods to modify the IPR curve to incorporate changes in skin factor are presented. A new flow-efficiency definition based on the structure of the deliverability equations for solution-gas-drive reservoirs is proposed. This definition avoids problems that result when the currently available methods are applied to heavily stimulated wells.

Camacho-V, R.G.; Raghavan, R.

1989-05-01T23:59:59.000Z

266

Optimum Statistical Test Procedure  

E-Print Network [OSTI]

In this paper we obtain a test which minimizes the sum of the two error probabilities irrespective of whether $\\sigma^2$ is known or unknown.

Rajesh Singh; Jayant Singh; Florentin Smarandache

2009-04-10T23:59:59.000Z

267

MITG Test Plan  

SciTech Connect (OSTI)

The plan presented is for the testing of a prototypical slice of the Modular Isotopic Thermoelectric Generator (MITG). Cross Reference T48-1.

Eck, Marshall B.

1981-08-01T23:59:59.000Z

268

Are Simple Real Pole Solutions Physical?  

E-Print Network [OSTI]

We consider exact solutions generated by the inverse scattering technique, also known as the soliton transformation. In particular, we study the class of simple real pole solutions. For quite some time, those solutions have been considered interesting as models of cosmological shock waves. A coordinate singularity on the wave fronts was removed by a transformation which induces a null fluid with negative energy density on the wave front. This null fluid is usually seen as another coordinate artifact, since there seems to be a general belief that that this kind of solution can be seen as the real pole limit of the smooth solution generated with a pair of complex conjugate poles in the transformation. We perform this limit explicitly, and find that the belief is unfounded: two coalescing complex conjugate poles cannot yield a solution with one real pole. Instead, the two complex conjugate poles go to a different limit, what we call a ``pole on a pole''. The limiting procedure is not unique; it is sensitive to how quickly some parameters approach zero. We also show that there exists no improved coordinate transformation which would remove the negative energy density. We conclude that negative energy is an intrinsic part of this class of solutions.

M Berg; M Bradley

2000-02-11T23:59:59.000Z

269

Summary of Test Results for the Interagency Field Test &Evaluation...  

Broader source: Energy.gov (indexed) [DOE]

Summary of Test Results for the Interagency Field Test &Evaluation of Wind Turbine - Radar Interference Mitigation Technologies Summary of Test Results for the Interagency Field...

270

Detonability of DMSO/LX-10-1 and DMSO/PBX-9404 solutions  

SciTech Connect (OSTI)

Although Lawrence Livermore National Laboratory has been involved in weapons disassembly since its involvement in weapons design, the Lab was recently requested by the Department of Energy to extend its responsibility for LLNL-designed weapons to include dismantlement of some systems in the cold war arsenal. Dissolution of LX-10-1 and PBX-9404 explosive from two artillery fired atomic projectiles (AFAPs) can be accomplished using dimethyl sulfoxide. The composition of LX-10-1 and PBX-9404 are given. The authors have evaluated the detonability of solutions of these two plastic bonded explosives in dimethyl sulfoxide (DMSO) under shock and thermal scenarios based on the UN ``Recommendations on the Transport of Dangerous Goods - Tests and Criteria`` (ST/SG/AC.10/11) and US Army Technical Bulletin 700-2. Prior to the relatively large scale shock and thermal sensitivity testing, small scale safety tests and thermochemical code calculations were used as a preliminary estimate of the detonability and hazards associated with up to 33% of these explosives in DMSO. Thermochemical calculations, small scale safety testing, and gap testing all indicate that these solutions are not detonable. They are currently in the process of evaluating these solutions using the small scale cookoff bomb (SCB) test.

Helm, F.; Hoffman, D.M.

1994-06-29T23:59:59.000Z

271

Blending of Radioactive Salt Solutions in Million Gallon Tanks - 13002  

SciTech Connect (OSTI)

Research was completed at Savannah River National Laboratory (SRNL) to investigate processes related to the blending of radioactive, liquid waste, salt solutions in 4920 cubic meter, 25.9 meter diameter storage tanks. One process was the blending of large salt solution batches (up to 1135 - 3028 cubic meters), using submerged centrifugal pumps. A second process was the disturbance of a settled layer of solids, or sludge, on the tank bottom. And a third investigated process was the settling rate of sludge solids if suspended into slurries by the blending pump. To investigate these processes, experiments, CFD models (computational fluid dynamics), and theory were applied. Experiments were performed using simulated, non-radioactive, salt solutions referred to as supernates, and a layer of settled solids referred to as sludge. Blending experiments were performed in a 2.44 meter diameter pilot scale tank, and flow rate measurements and settling tests were performed at both pilot scale and full scale. A summary of the research is presented here to demonstrate the adage that, 'One good experiment fixes a lot of good theory'. Experimental testing was required to benchmark CFD models, or the models would have been incorrectly used. In fact, CFD safety factors were established by this research to predict full-scale blending performance. CFD models were used to determine pump design requirements, predict blending times, and cut costs several million dollars by reducing the number of required blending pumps. This research contributed to DOE missions to permanently close the remaining 47 of 51 SRS waste storage tanks. (authors)

Leishear, Robert A.; Lee, Si Y.; Fowley, Mark D.; Poirier, Michael R. [Savannah River National Laboratory, Aiken. S.C., 29808 (United States)] [Savannah River National Laboratory, Aiken. S.C., 29808 (United States)

2013-07-01T23:59:59.000Z

272

Blending Of Radioactive Salt Solutions In Million Gallon Tanks  

SciTech Connect (OSTI)

Research was completed at Savannah River National Laboratory (SRNL) to investigate processes related to the blending of radioactive, liquid waste, salt solutions in 4920 cubic meter, 25.9 meter diameter storage tanks. One process was the blending of large salt solution batches (up to 1135 ? 3028 cubic meters), using submerged centrifugal pumps. A second process was the disturbance of a settled layer of solids, or sludge, on the tank bottom. And a third investigated process was the settling rate of sludge solids if suspended into slurries by the blending pump. To investigate these processes, experiments, CFD models (computational fluid dynamics), and theory were applied. Experiments were performed using simulated, non-radioactive, salt solutions referred to as supernates, and a layer of settled solids referred to as sludge. Blending experiments were performed in a 2.44 meter diameter pilot scale tank, and flow rate measurements and settling tests were performed at both pilot scale and full scale. A summary of the research is presented here to demonstrate the adage that, ?One good experiment fixes a lot of good theory?. Experimental testing was required to benchmark CFD models, or the models would have been incorrectly used. In fact, CFD safety factors were established by this research to predict full-scale blending performance. CFD models were used to determine pump design requirements, predict blending times, and cut costs several million dollars by reducing the number of required blending pumps. This research contributed to DOE missions to permanently close the remaining 47 of 51 SRS waste storage tanks.

Leishear, Robert A.; Lee, Si Y.; Fowley, Mark D.; Poirier, Michael R.

2012-12-10T23:59:59.000Z

273

Standard test methods for arsenic in uranium hexafluoride  

E-Print Network [OSTI]

1.1 These test methods are applicable to the determination of total arsenic in uranium hexafluoride (UF6) by atomic absorption spectrometry. Two test methods are given: Test Method A—Arsine Generation-Atomic Absorption (Sections 5-10), and Test Method B—Graphite Furnace Atomic Absorption (Appendix X1). 1.2 The test methods are equivalent. The limit of detection for each test method is 0.1 ?g As/g U when using a sample containing 0.5 to 1.0 g U. Test Method B does not have the complete collection details for precision and bias data thus the method appears as an appendix. 1.3 Test Method A covers the measurement of arsenic in uranyl fluoride (UO2F2) solutions by converting arsenic to arsine and measuring the arsine vapor by flame atomic absorption spectrometry. 1.4 Test Method B utilizes a solvent extraction to remove the uranium from the UO2F2 solution prior to measurement of the arsenic by graphite furnace atomic absorption spectrometry. 1.5 Both insoluble and soluble arsenic are measured when UF6 is...

American Society for Testing and Materials. Philadelphia

2005-01-01T23:59:59.000Z

274

Standard Test Method for Sandwich Corrosion Test  

E-Print Network [OSTI]

1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

American Society for Testing and Materials. Philadelphia

2009-01-01T23:59:59.000Z

275

Properties of lead-lithium solutions  

SciTech Connect (OSTI)

Lead-lithium solutions are of interest to liquid metal wall ICF reactor designers because Pb may be present to some extent in both heavy ion beam and laser-driven ICF targets; therefore, Pb will be present as an impurity in a flowing lithium wall. In addition, Pb-Li solutions containing approx. 80 a/o Pb are a strong candidate for a heavy ion beam driven HYLIFE converter and a viable alternative to a pure Li wall for a laser driven converter. The properties of Pb-Li solutions including the effect of hydrogen impurities are reviewed, and the reactor design implications are discussed.

Hoffman, N.J.; Darnell, A.; Blink, J.A.

1980-10-01T23:59:59.000Z

276

Stabilization of polyaniline solutions through additives  

DOE Patents [OSTI]

A stabilized non-conductive polyaniline solution comprising from about 1 to about 10 percent by weight polyaniline or a polyaniline derivative, from about 90 to about 99 percent by weight N-methylpyrrolidone, and from about 0.5 percent by weight to about 15 percent by weight of a solution stabilizing additive selected from the group consisting of hindered amine light stabilizers, polymeric amines, and dialkylamines, percent by weight of additive based on the total weight of polyaniline or polyaniline derivative is provided together with a method for stabilizing a polyaniline solution. 4 figs.

Wrobleski, D.A.; Benicewicz, B.C.

1996-12-10T23:59:59.000Z

277

Stabilization of polyaniline solutions through additives  

DOE Patents [OSTI]

A stabilized non-conductive polyaniline solution comprising from about 1 to bout 10 percent by weight polyaniline or a polyaniline derivative, from about 90 to about 99 percent by weight N-methylpyrrolidone, and from about 0.5 percent by weight to about 15 percent by weight of a solution stabilizing additive selected from the group consisting of hindered amine light stabilizers, polymeric amines, and dialkylamines, percent by weight of additive based on the total weight of polyaniline or polyaniline derivative is provided together with a method for stabilizing a polyaniline solution.

Wrobleski, Debra A. (Los Alamos, NM); Benicewicz, Brian C. (Los Alamos, NM)

1996-01-01T23:59:59.000Z

278

Animal Health Diagnostic Center Test and Fee Schedule Test Name Test Fee Discipline Test Days Lag** Samples Container Coolant Comments  

E-Print Network [OSTI]

Animal Health Diagnostic Center Test and Fee Schedule Test Name Test Fee Discipline Test Days Lag** Samples Container Coolant Comments Equine Tests Equine Tests Acid Fast Stain (for bacteria) M-F 1-2 days 1 4 hours for equine. For more information, see Equine Cushing's Tests or AppendixC. For Equine only

Keinan, Alon

279

Animal Health Diagnostic Center Test and Fee Schedule Test Name Test Fee Discipline Test Days Lag** Samples Container Coolant Comments  

E-Print Network [OSTI]

Animal Health Diagnostic Center Test and Fee Schedule Test Name Test Fee Discipline Test Days Lag** Samples Container Coolant Comments Canine Tests Canine Tests Acid Fast Stain (for bacteria) M-F 1-2 days 1 in insulated container with ice pack. For more information, see Canine Adrenal & Pituitary Function Tests

Keinan, Alon

280

Solar system tests of brane world models  

E-Print Network [OSTI]

The classical tests of general relativity (perihelion precession, deflection of light, and the radar echo delay) are considered for the Dadhich, Maartens, Papadopoulos and Rezania (DMPR) solution of the spherically symmetric static vacuum field equations in brane world models. For this solution the metric in the vacuum exterior to a brane world star is similar to the Reissner-Nordstrom form of classical general relativity, with the role of the charge played by the tidal effects arising from projections of the fifth dimension. The existing observational solar system data on the perihelion shift of Mercury, on the light bending around the Sun (obtained using long-baseline radio interferometry), and ranging to Mars using the Viking lander, constrain the numerical values of the bulk tidal parameter and of the brane tension.

Christian G. Boehmer; Tiberiu Harko; Francisco S. N. Lobo

2008-02-05T23:59:59.000Z

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

UrbanSolutionsCenter Evaluation of Best Management Practices (BMPs) for Reducing Non-Point  

E-Print Network [OSTI]

water bodies. · Reduced erosion from agricultural and urban lands will help sustain soil fertilityUrbanSolutionsCenter Evaluation of Best Management Practices (BMPs) for Reducing Non-Point Source of the reservoir cannot be achieved without identifying, testing and implementing appropriate best management

282

On exact and perturbation solutions to nonlinear equations for heat transfer models  

E-Print Network [OSTI]

We analyze some exact and approximate solutions to nonlinear equations for heat transfer models. We prove that recent results derived from a method based on Lie algebras are either trivial or wrong. We test a simple analytical expression based on the hypervirial theorem and also discuss earlier perturbation results.

Francisco M. Fernández

2009-11-03T23:59:59.000Z

283

Advanced Test Reactor Tour  

SciTech Connect (OSTI)

The Advanced Test Reactor at Idaho National Laboratory is the foremost nuclear materials test reactor in the world. This virtual tour describes the reactor, how experiments are conducted, and how spent nuclear fuel is handled and stored. For more information about INL research, visit http://www.facebook.com/idahonationallaboratory.

Miley, Don

2011-01-01T23:59:59.000Z

284

Advanced Test Reactor Tour  

ScienceCinema (OSTI)

The Advanced Test Reactor at Idaho National Laboratory is the foremost nuclear materials test reactor in the world. This virtual tour describes the reactor, how experiments are conducted, and how spent nuclear fuel is handled and stored. For more information about INL research, visit http://www.facebook.com/idahonationallaboratory.

Miley, Don

2013-05-28T23:59:59.000Z

285

Cylinder Test Specification  

SciTech Connect (OSTI)

The purpose of the cylinder testis two-fold: (1) to characterize the metal-pushing ability of an explosive relative to that of other explosives as evaluated by the E{sub 19} cylinder energy and the G{sub 19} Gurney energy and (2) to help establish the explosive product equation-of-state (historically, the Jones-Wilkins-Lee (JWL) equation). This specification details the material requirements and procedures necessary to assemble and fire a typical Los Alamos National Laboratory (LANL) cylinder test. Strict adherence to the cylinder. material properties, machining tolerances, material heat-treatment and etching processes, and high explosive machining tolerances is essential for test-to-test consistency and to maximize radial wall expansions. Assembly and setup of the cylinder test require precise attention to detail, especially when placing intricate pin wires on the cylinder wall. The cylinder test is typically fired outdoors and at ambient temperature.

Richard Catanach; Larry Hill; Herbert Harry; Ernest Aragon; Don Murk

1999-10-01T23:59:59.000Z

286

Hypersonic flight testing  

SciTech Connect (OSTI)

As part of the design process for a hypersonic vehicle, it is necessary to predict the aerodynamic and aerothermodynamic environment for flight conditions. This involves combining results obtained from ground testing with analytical modeling to predict the aerodynamics and heating for all conditions of interest. The question which always arises is, how well will these models predict what is actually seen in a flight environment This paper will briefly address ground-testing and analytical modeling and discuss where each is appropriate, and the associated problems with each area. It will then describe flight test options as well as instrumentation currently available and show how flight tests can be used to validate or improve models. Finally, several results will be shown to indicate areas where ground testing and modeling alone are inadequate to accurately predict hypersonic aerodynamics and aerothermodynamics.

Williamson, W.E.

1992-01-01T23:59:59.000Z

287

Nanomechanical testing system  

DOE Patents [OSTI]

An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.

Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David

2014-07-08T23:59:59.000Z

288

En beskrivning av manuellt test.  

E-Print Network [OSTI]

?? Test is an area in system development. Test can be performed manually or automated. Test activities can be supported by Word documents and Excel… (more)

Artursson Wissa, Ulrika

2011-01-01T23:59:59.000Z

289

Wind Technology Testing Center Acquires New Blade Fatigue Test...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Technology Testing Center Acquires New Blade Fatigue Test System Wind Technology Testing Center Acquires New Blade Fatigue Test System August 1, 2013 - 4:33pm Addthis This is an...

290

SOFTWARE TESTING, VERIFICATION AND RELIABILITY Softw. Test. Verif. Reliab. (2014)  

E-Print Network [OSTI]

. An industrial case study using reactor protection system software shows that the automatically generated test defined by the International Electrotechnical Commission (IEC). Industrial FBD testing relies mostlySOFTWARE TESTING, VERIFICATION AND RELIABILITY Softw. Test. Verif. Reliab. (2014) Published online

291

Glass bead micromodel study of solute transport  

E-Print Network [OSTI]

This study presents the quantification of glass bead micromodel experiments through a combination of computational modeling and experimental analysis. The computational model simulates two-dimensional solute flow through porous media using a finite...

Fedirchuk, Paula Diane

1995-01-01T23:59:59.000Z

292

STAT 416 Fall 2014 Homework 6 Solutions  

E-Print Network [OSTI]

Nov 3, 2014 ... STAT 416 Fall 2014. Homework 6 Solutions ... 4.35 Let X denote the winnings. P (X = 1.1) = P (both marbles red) + P (both marbles blue) = 2. (5.

2014-11-03T23:59:59.000Z

293

Concentrating aqueous acetate solutions with tertiary amines  

E-Print Network [OSTI]

Water may be extracted from aqueous calcium acetate or sodium acetate solutions using low miscibility, low molecular weight tertiary amines, e.g. triethylamine (TEA) and N,N- dietliylmethylaniine (DEMA). This novel extraction technology...

Lee, Champion

1993-01-01T23:59:59.000Z

294

IID Energy- PV Solutions Rebate Program  

Broader source: Energy.gov [DOE]

'''''IID accepted applications for the 2013 PV Solutions Program from Jan. 2, 2013 – Jan. 31, 2013. Winners were determined via lottery. The program is now closed for the remainder of 2013, but...

295

Removal of metal ions from aqueous solution  

DOE Patents [OSTI]

A method of removing heavy metals from aqueous solution, a composition of matter used in effecting said removal, and apparatus used in effecting said removal. One or more of the polypeptides, poly (.gamma.-glutamylcysteinyl)glycines, is immobilized on an inert material in particulate form. Upon contact with an aqueous solution containing heavy metals, the polypeptides sequester the metals, removing them from the solution. There is selectivity of poly (.gamma.-glutamylcysteinyl)glycines having a particular number of monomer repeat unit for particular metals. The polypeptides are easily regenerated by contact with a small amount of an organic acid, so that they can be used again to remove heayv metals from solution. This also results in the removal of the metals from the column in a concentrated form.

Jackson, Paul J. (both Los Alamos, NM); Delhaize, Emmanuel (both Los Alamos, NM); Robinson, Nigel J. (Durham, GB2); Unkefer, Clifford J. (Los Alamos, NM); Furlong, Clement (Seattle, WA)

1990-11-13T23:59:59.000Z

296

Removal of metal ions from aqueous solution  

DOE Patents [OSTI]

A method of removing heavy metals from aqueous solution, a composition of matter used in effecting said removal, and apparatus used in effecting said removal. One or more of the polypeptides, poly (.gamma.-glutamylcysteinyl)glycines, is immobilized on an inert material in particulate form. Upon contact with an aqueous solution containing heavy metals, the polypeptides sequester the metals, removing them from the solution. There is selectivity of poly (.gamma.-glutamylcysteinyl)glycines having a particular number of monomer repeat units for particular metals. The polypeptides are easily regenerated by contact with a small amount of an organic acid, so that they can be used again to remove heavy metals from solution. This also results in the removal of the metals from the column in a concentrated form.

Jackson, Paul J. (Los Alamos, NM); Delhaize, Emmanuel (Los Alamos, NM); Robinson, Nigel J. (Durham, GB2); Unkefer, Clifford J. (Los Alamos, NM); Furlong, Clement (Seattle, WA)

1990-01-01T23:59:59.000Z

297

Generating Geodesic Flows and Supergravity Solutions  

E-Print Network [OSTI]

We consider the geodesic motion on the symmetric moduli spaces that arise after timelike and spacelike reductions of supergravity theories. The geodesics correspond to timelike respectively spacelike $p$-brane solutions when they are lifted over a $p$-dimensional flat space. In particular, we consider the problem of constructing \\emph{the minimal generating solution}: A geodesic with the minimal number of free parameters such that all other geodesics are generated through isometries. We give an intrinsic characterization of this solution in a wide class of orbits for various supergravities in different dimensions. We apply our method to three cases: (i) Einstein vacuum solutions, (ii) extreme and non-extreme D=4 black holes in N=8 supergravity and their relation to N=2 STU black holes and (iii) Euclidean wormholes in $D\\geq 3$. In case (iii) we present an easy and general criterium for the existence of regular wormholes for a given scalar coset.

E. Bergshoeff; W. Chemissany; A. Ploegh; M. Trigiante; T. Van Riet

2008-10-30T23:59:59.000Z

298

EIS-0219: F-Canyon Plutonium Solutions  

Broader source: Energy.gov [DOE]

This EIS evaluates the potential environmental impacts of processing the plutonium solutions to metal form using the F-Canyon and FB-Line facilities at the Savannah River Site.

299

Lightweight Steel Solutions for Automotive Industry  

SciTech Connect (OSTI)

Recently, improvement in fuel efficiency and safety has become the biggest issue in worldwide automotive industry. Although the regulation of environment and safety has been tightened up more and more, the majority of vehicle bodies are still manufactured from stamped steel components. This means that the optimized steel solutions enable to demonstrate its ability to reduce body weight with high crashworthiness performance instead of expensive light weight materials such as Al, Mg and composites. To provide the innovative steel solutions for automotive industry, POSCO has developed AHSS and its application technologies, which is directly connected to EVI activities. EVI is a technical cooperation program with customer covering all stages of new car project from design to mass production. Integrated light weight solutions through new forming technologies such as TWB, hydroforming and HPF are continuously developed and provided for EVI activities. This paper will discuss the detailed status of these technologies especially light weight steel solutions based on innovative technologies.

Lee, Hong Woo; Kim, Gyosung; Park, Sung Ho [Technical Research Laboratories, POSCO, 699, Gumho-dong, Gwangyang-si, Jeonnam, 545-090 (Korea, Republic of)

2010-06-15T23:59:59.000Z

300

one was tested, all reaction mixtures were supple-mented with an appropriate amount of ethanol  

E-Print Network [OSTI]

one was tested, all reaction mixtures were supple- mented with an appropriate amount of ethanol (5% v/v), because the menadione was dissolved in ethanol as a stock solution. The reaction was ini

Moorcroft, Paul R.

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Missing solution in a Cornell potential  

SciTech Connect (OSTI)

Missing bound-state solutions for fermions in the background of a Cornell potential consisting of a mixed scalar–vector–pseudoscalar coupling is examined. Charge-conjugation operation, degeneracy and localization are discussed. -- Highlights: •The Dirac equation with scalar–vector–pseudoscalar Cornell potential is investigated. •The isolated solution from the Sturm–Liouville problem is found. •Charge-conjugation operation, degeneracy and localization are discussed.

Castro, L.B., E-mail: luis.castro@pgfsc.ufsc.br [Departamento de Física, CFM, Universidade Federal de Santa Catarina, 88040-900, Florianópolis - SC (Brazil); Castro, A.S. de, E-mail: castro@pq.cnpq.br [Departamento de Física e Química, Campus de Guaratinguetá, Universidade Estadual Paulista, 12516-410, Guaratinguetá - SP (Brazil)] [Departamento de Física e Química, Campus de Guaratinguetá, Universidade Estadual Paulista, 12516-410, Guaratinguetá - SP (Brazil)

2013-11-15T23:59:59.000Z

302

Solutions of systems of ordinary differential equations  

E-Print Network [OSTI]

SOLUTIONS OF SYSTEMS OF ORDINARY DIFFERENTIAL EQUATIONS A Thesis By CLAUDE EVANS KITCHENS Submitted to the Graduate College of the Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE May 1967... Major Subject: Mathematics SOLUTIONS OF SYSTEMS OF ORDINARY DIFFERENTIAL EQUATIONS A Thesis By CLAUDE EVANS KITCHENS Approved as to style and content by: (Chairman of Commi e) (Nember (Hea of Departmen (H er May 1967 ACKNOWLEDGMENTS I wish...

Kitchens, Claude Evans

1967-01-01T23:59:59.000Z

303

Embeddings for solutions of Einstein equations  

E-Print Network [OSTI]

We study isometric embeddings of some solutions of the Einstein equations with suffciently high symmetries into a flat ambient space. We briefly describe a method for constructing surfaces with a given symmetry. We discuss all minimal embeddings of the Schwarzschild metric obtained using this method and show how the method can be used to construct all minimal embeddings for the Friedmann models. We classify all the embeddings in terms of realizations of symmetries of the corresponding solutions.

S. A. Paston; A. A. Sheykin

2013-06-20T23:59:59.000Z

304

GELATIN SUBBED SLIDES (SOP-21) GELATIN SOLUTION  

E-Print Network [OSTI]

GELATIN SUBBED SLIDES (SOP-21) GELATIN SOLUTION · Warm 1000 ml dH2O to 70° C (Do not heat water. Solution may be stored in the refrigerator for up to l week. CLEANING SLIDES · Fill a staining dish with 1:1 mixture of 95 % (v/v) ethanol and glacial acetic acid. · Soak slides placed in large metal slide rack

Kleinfeld, David

305

Solution dewatering with concomitant ion removal  

DOE Patents [OSTI]

One of the biggest needs in the separations and waste handling and reduction area is a method for dewatering ion-containing solutions. Unexpectedly, it has been found that phosphazene polymers can discriminate between water and metal ions, allowing water to pass through the membrane while retaining the ions. This unexpected result, along with the inherent chemical and thermal stability of the phosphazene polymers, yields a powerful tool for separating and dewatering metal-ion-containing solutions.

Peterson, Eric S.; Marshall, Douglas W.; Stone, Mark L.

2003-08-05T23:59:59.000Z

306

Community Renewable Solutions LLC | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentratingRenewable Solutions LLC Jump to: navigation, search Name: Community Renewable Solutions

307

Water Research 38 (2004) 33313339 Testing a surface tension-based model to predict the salting  

E-Print Network [OSTI]

Water Research 38 (2004) 3331­3339 Testing a surface tension-based model to predict the salting out associated with transferring solutes from water to a salt solution to the difference in surface tensions likely reflects the inability of the simple surface tension model to account for all interactions among

Herbert, Bruce

308

Advancing Toward Test Automation through Effective Manual Testing  

E-Print Network [OSTI]

. This paper will walk through a best practice scenario for using Manual Tester to more naturally organize test Automation through Effective Manual Testing Bob Levy, Lead Product Manager ­ Functional Test Dennis ElenburgAdvancing Toward Test Automation through Effective Manual Testing May 2005 Advancing Toward Test

309

Edit Test Options Page 1 Edit Test Options  

E-Print Network [OSTI]

Edit Test Options Page 1 Edit Test Options Format Test Information 1. Enter a Name for the Test. 2. Choose a color for the title text of the Test. (Optional) 3. Enter a Description in the Text Box. The description is visible to Students before they click on the link to take the Test. (Optional) 4. If you want

Xu, Shouhuai

310

Thermal test options  

SciTech Connect (OSTI)

Shipping containers for radioactive materials must be qualified to meet a thermal accident environment specified in regulations, such at Title 10, Code of Federal Regulations, Part 71. Aimed primarily at the shipping container design, this report discusses the thermal testing options available for meeting the regulatory requirements, and states the advantages and disadvantages of each approach. The principal options considered are testing with radiant heat, furnaces, and open pool fires. The report also identifies some of the facilities available and current contacts. Finally, the report makes some recommendations on the appropriate use of these different testing methods.

Koski, J.A.; Keltner, N.R.; Sobolik, K.B.

1993-02-01T23:59:59.000Z

311

THE FINAL SERIES OF OILS TESTED AS A POTENTIAL SOLUTION TO THE GALVESTON FERRY  

E-Print Network [OSTI]

two other diesel engines that are used for auxiliary power generation, and none of those dieselDOT) began using an ultra-low sulfur diesel fuel, Texas Low Emission Diesel (TxLED), in all of its diesel manufacturer, ElectroMotive Diesels (EMD), with one exception. This unapproved oil contained zinc

Texas at Austin, University of

312

MA373 F13 Test 4-1 Solutions.pdf  

E-Print Network [OSTI]

Dec 10, 2013 ... which is less that the real forward price of. 75.12. ... European-style call options on Conway Corporation with the following strike prices and call.

jeffb_000

2014-04-29T23:59:59.000Z

313

Rotordynamic coefficients for shrouded pump impellers: comparisons between a new computer solution and test results  

E-Print Network [OSTI]

a, = f ? NiH (Mk) dV 4i k Jv() P a 12):f MkP (Nj) dV a14), =f M?G (N. ) dV ait), =f MkH(N ) dV 20 d) f, ()d-(i. (4 ) dd 0 f+d, 'Qd, , )dd 1=1 20 d ) f()=ddt. ( )dd 0 f d Qdd )dd 1=1 b, ) =f (), Ni (n vw) dS In the above equations: a. (e..., to be used as input to the perturbation analysis, are included in Appendix A. The assembled form of these equations can be written in the following compact form: [~] [g) =[a) (12) where [A] is the matrix of influence coefficients [I) is the vector...

Daniel, Arul Sathyasundar

1992-01-01T23:59:59.000Z

314

Chem 3411 test #2 solutions out of 30 marks. Problem 1 10 marks  

E-Print Network [OSTI]

required is 1.35 times that for reversible operation. What electrical power (in watts) must be supplied to go from H2O(liquid, 288 K) H2O(solid, 273 K) at constant pressure? Cooling the liquid takes qJ. To produce this amount of ice (ie. transfer this amount of heat) every minute, the electrical power supplied

Nielsen, Steven O.

315

SATURATED ZONE IN-SITU TESTING  

SciTech Connect (OSTI)

The purpose of this scientific analysis is to document the results and interpretations of field experiments that test and validate conceptual flow and radionuclide transport models in the saturated zone (SZ) near Yucca Mountain, Nevada. The test interpretations provide estimates of flow and transport parameters used in the development of parameter distributions for total system performance assessment (TSPA) calculations. These parameter distributions are documented in ''Site-Scale Saturated Zone Flow Model (BSC 2004 [DIRS 170037]), Site-Scale Saturated Zone Transport'' (BSC 2004 [DIRS 170036]), Saturated Zone Colloid Transport (BSC 2004 [DIRS 170006]), and ''Saturated Zone Flow and Transport Model Abstraction'' (BSC 2004 [DIRS 170042]). Specifically, this scientific analysis contributes the following to the assessment of the capability of the SZ to serve as part of a natural barrier for waste isolation for the Yucca Mountain repository system: (1) The bases for selection of conceptual flow and transport models in the saturated volcanics and the saturated alluvium located near Yucca Mountain. (2) Results and interpretations of hydraulic and tracer tests conducted in saturated fractured volcanics at the C-wells complex near Yucca Mountain. The test interpretations include estimates of hydraulic conductivities, anisotropy in hydraulic conductivity, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, matrix diffusion coefficients, fracture apertures, and colloid transport parameters. (3) Results and interpretations of hydraulic and tracer tests conducted in saturated alluvium at the Alluvial Testing Complex (ATC) located at the southwestern corner of the Nevada Test Site (NTS). The test interpretations include estimates of hydraulic conductivities, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, and colloid transport parameters. (4) Comparisons of sorption parameter estimates for a reactive solute tracer (lithium ion) derived from the C-wells field tracer tests and laboratory tests using C-wells core samples. (5) Sorption parameter estimates for lithium ion derived from laboratory tests using alluvium samples from ATC well NC-EWDP-19D. These estimates will allow a comparison of laboratory- and field-derived sorption parameters to be made in saturated alluvium if cross-hole tracer tests are conducted at the ATC.

P.W. REIMUS

2004-11-08T23:59:59.000Z

316

Saturated Zone In-Situ Testing  

SciTech Connect (OSTI)

The purpose of this scientific analysis is to document the results and interpretations of field experiments that have been conducted to test and validate conceptual flow and radionuclide transport models in the saturated zone (SZ) near Yucca Mountain. The test interpretations provide estimates of flow and transport parameters that are used in the development of parameter distributions for Total System Performance Assessment (TSPA) calculations. These parameter distributions are documented in the revisions to the SZ flow model report (BSC 2003 [ 162649]), the SZ transport model report (BSC 2003 [ 162419]), the SZ colloid transport report (BSC 2003 [162729]), and the SZ transport model abstraction report (BSC 2003 [1648701]). Specifically, this scientific analysis report provides the following information that contributes to the assessment of the capability of the SZ to serve as a barrier for waste isolation for the Yucca Mountain repository system: (1) The bases for selection of conceptual flow and transport models in the saturated volcanics and the saturated alluvium located near Yucca Mountain. (2) Results and interpretations of hydraulic and tracer tests conducted in saturated fractured volcanics at the C-wells complex near Yucca Mountain. The test interpretations include estimates of hydraulic conductivities, anisotropy in hydraulic conductivity, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, matrix diffusion coefficients, fracture apertures, and colloid transport parameters. (3) Results and interpretations of hydraulic and tracer tests conducted in saturated alluvium at the Alluvium Testing Complex (ATC), which is located at the southwestern corner of the Nevada Test Site (NTS). The test interpretations include estimates of hydraulic conductivities, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, and colloid transport parameters. (4) Comparisons of sorption parameter estimates for a reactive solute tracer (lithium ion) derived from both the C-wells field tracer tests and laboratory tests using C-wells core samples. (5) Sorption parameter estimates for lithium ion derived from laboratory tests using alluvium samples from NC-EWDP-19D1 (one of the wells at the ATC) so that a comparison of laboratory- and field-derived sorption parameters can be made in saturated alluvium if cross-hole tracer tests are conducted at the ATC.

P. W. Reimus; M. J. Umari

2003-12-23T23:59:59.000Z

317

Hanford Tank Farms Waste Certification Flow Loop Test Plan  

SciTech Connect (OSTI)

A future requirement of Hanford Tank Farm operations will involve transfer of wastes from double shell tanks to the Waste Treatment Plant. As the U.S. Department of Energy contractor for Tank Farm Operations, Washington River Protection Solutions anticipates the need to certify that waste transfers comply with contractual requirements. This test plan describes the approach for evaluating several instruments that have potential to detect the onset of flow stratification and critical suspension velocity. The testing will be conducted in an existing pipe loop in Pacific Northwest National Laboratory’s facility that is being modified to accommodate the testing of instruments over a range of simulated waste properties and flow conditions. The testing phases, test matrix and types of simulants needed and the range of testing conditions required to evaluate the instruments are described

Bamberger, Judith A.; Meyer, Perry A.; Scott, Paul A.; Adkins, Harold E.; Wells, Beric E.; Blanchard, Jeremy; Denslow, Kayte M.; Greenwood, Margaret S.; Morgen, Gerald P.; Burns, Carolyn A.; Bontha, Jagannadha R.

2010-01-01T23:59:59.000Z

318

ISOPAR L RELEASE RATES FROM SALTSTONE USING SIMULATED SALT SOLUTIONS  

SciTech Connect (OSTI)

The Modular Caustic-Side Solvent Extraction (CSSX) Unit (MCU) and the Salt Waste Processing Facility (SWPF) will produce a Decontaminated Salt Solution (DSS) that will go to the Saltstone Production Facility (SPF). Recent information indicates that solvent entrainment in the DSS is larger than expected. The main concern is with Isopar{reg_sign} L, the diluent in the solvent mixture, and its flammability in the saltstone vault. If it is assumed that all the Isopar{reg_sign} L is released instantaneously into the vault from the curing grout before each subsequent pour, the Isopar{reg_sign} L in the vault headspace is well mixed, and each pour displaces an equivalent volume of headspace, the maximum concentration of Isopar{reg_sign} L in the DSS to assure 25% of the lower flammable limit is not exceeded has been determined to be about 4 ppm. The amount allowed would be higher if the release from grout were significantly less. The Savannah River National Laboratory was tasked with determining the release of Isopar{reg_sign} L from saltstone prepared with a simulated DSS with Isopar{reg_sign} L concentrations ranging from 50 to 200 mg/L in the salt fraction and with test temperatures ranging from ambient to 95 C. The results from the curing of the saltstone showed that the amount of Isopar{reg_sign} L released versus time can be treated as a percentage of initial amount present; there was no statistically significant dependence of the release rate on the initial concentration. The majority of the Isopar{reg_sign} L that was released over the test duration was released in the first few days. The release of Isopar{reg_sign} L begins immediately and the rate of release decreases over time. At higher temperatures the immediate release rate is larger than at lower temperatures. Initial curing temperature was found to be very important as slight variations during the first few hours or days had a significant effect on the amount of Isopar{reg_sign} L released. Short scoping tests at 95 C with solvent containing all components (Isopar{reg_sign} L, suppressor trioctylamine (TOA), and modifier Cs-7SB) except the BOBCalixC6 extractant released less Isopar{reg_sign} L than the tests run with Isopar{reg_sign} L/TOA. Based on these scoping tests, the Isopar{reg_sign} L releases reported herein are conservative. Isopar{reg_sign} L release was studied for a two-month period and average cumulative release rates were determined from three sets of tests each at 95 and 75 C and at ambient conditions. The overall average releases at were estimated for each temperature. For the 95 and 75 C data, at a 5% significance level, the hypothesis that the three test sets at each temperature had the same average percent release can be rejected, suggesting that there was a statistically significant difference among the three averages seen in the three experimental tests conducted. An upper confidence limit on the mean percent release required incorporation of variation from two sources: test-to-test variation as well as the variation within a test. An analysis of variance that relies on a random effects model was used to estimate the two variance components. The test-to-test variance and the within test (or residual) variance were both calculated. There is no indication of a statistically significant linear correlation between the percent Isopar{reg_sign} L release and the Isopar{reg_sign} L initial concentration. From the analysis of variance, upper confidence limits at confidences of 80-95% were calculated for the data at 95 and 75 C. The mean Isopar{reg_sign} L percent releases were 67.33% and 13.17% at 95 and 75 C, respectively.

Zamecnik, J; Michael Bronikowski, M; Alex Cozzi, A; Russell Eibling, R; Charles Nash, C

2008-07-31T23:59:59.000Z

319

Laboratory testing of repellents to prevent nutria damage to seismic cable  

E-Print Network [OSTI]

. The adhesive used was Rhoplex AC-33, manufactured by the Rohm and Haas Company. This excellent adhesive is highly flexible, and has good weathering characteristics. The type of cable used to test the chemical repellents was two-conductor geophone strings... cable, chemically treated test cables, and internally armored cable. Bio-Met 12 and its derivation were tested in the form made available by the manufacturer. R-55 and Gustafson 425 were tested at the 10% solution of active ingredients in association...

Gunn, Scott Jeter

1980-01-01T23:59:59.000Z

320

CASL Test Stand Experience  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Test Stand concept was included in the CASL proposal to the US Department of Energy (DoE) as an important means to achieve early deployment of the M&S technology and...

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

MA 266 Practice Test  

E-Print Network [OSTI]

Feb 18, 2015 ... INSTRUCTIONS in the Test. 1. Do not open this exam booklet until told to do so. 2. There are 6 or 7 problems - one per page. 3. Show all your ...

2015-02-10T23:59:59.000Z

322

CALiPER Testing  

Broader source: Energy.gov [DOE]

The CALiPER (Commercially Available LED Product Evaluation and Reporting) program was launched by DOE in 2006 to support testing of a representative array of solid-state lighting products for general illumination, using industry-approved test procedures carried out by qualified test labs. The program has evolved right along with the SSL market and serves multiple needs. CALiPER testing and analysis identify trends, indicate SSL's suitability for particular applications, and detect secondary issues that require further scrutiny – such as glare, flicker, physical format, and reliability concerns. The program not only guides DOE planning and helps discourage low-quality products and inflated claims, but also serves as a useful tool for manufacturers seeking to improve their products, and for municipalities, utilities, and energy-efficiency programs seeking to make informed program decisions.

323

Schwarzschild-type solution in an effective gravitational theory with local Galilean invariance  

E-Print Network [OSTI]

We construct a Schwarzschild-type exact external solution for a theory of gravity admitting local Galilean invariance. In order to realize the Galilean invariance we need to adopt a five-dimensional manifold. The solution for the gravitational field equations obeys a Birkhoff-like theorem. Three classic tests of general relativity are analyzed in detail: the perihelion shift of the planet Mercury, the deflection of light by the Sun, and the gravitational redshift of atomic spectral lines. The Galilean version of these tests exhibits an additional parameter $b$ related to the fifth-coordinate. This constant $b$ can be estimated by a comparison with observational data. We observe that the Galilean theory is able to reproduce the results traditionally predicted by general relativity in the limit of negligible $b$. This shows that the tests are not specifically Lorentz invariant.

R. R. Cuzinatto; P. J. Pompeia; M. de Montigny; F. C. Khanna

2014-09-04T23:59:59.000Z

324

Investigation of ALEGRA shock hydrocode algorithms using an exact free surface jet flow solution.  

SciTech Connect (OSTI)

Computational testing of the arbitrary Lagrangian-Eulerian shock physics code, ALEGRA, is presented using an exact solution that is very similar to a shaped charge jet flow. The solution is a steady, isentropic, subsonic free surface flow with significant compression and release and is provided as a steady state initial condition. There should be no shocks and no entropy production throughout the problem. The purpose of this test problem is to present a detailed and challenging computation in order to provide evidence for algorithmic strengths and weaknesses in ALEGRA which should be examined further. The results of this work are intended to be used to guide future algorithmic improvements in the spirit of test-driven development processes.

Hanks, Bradley Wright.; Robinson, Allen Conrad

2014-01-01T23:59:59.000Z

325

Advanced Duct Sealing Testing  

SciTech Connect (OSTI)

Duct leakage has been identified as a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums or branches in the duct system. At each of these connections a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have typically shown that these seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory has been testing sealant durability for several years. Typical duct tape (i.e. fabric backed tapes with natural rubber adhesives) was found to fail more rapidly than all other duct sealants. This report summarizes the results of duct sealant durability testing of five UL 181B-FX listed duct tapes (three cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The first test involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars, and sheet metal ''collar-to-plenum joints'' pressurized with 200 F (93 C) air. The second test consisted of baking duct tape specimens in a constant 212 F (100 C) oven following the UL 181B-FX ''Temperature Test'' requirements. Additional tests were also performed on only two tapes using sheet metal collar-to-plenum joints. Since an unsealed flexible duct joint can have a variable leakage depending on the positioning of the flexible duct core, the durability of the flexible duct joints could not be based on the 10% of unsealed leakage criteria. Nevertheless, the leakage of the sealed specimens prior to testing could be considered as a basis for a failure criteria. Visual inspection was also documented throughout the tests. The flexible duct core-to-collar joints were inspected monthly, while the sheet metal collar-to-plenum joints were inspected weekly. The baking test specimens were visually inspected weekly, and the durability was judged by the observed deterioration in terms of brittleness, cracking, flaking and blistering (the terminology used in the UL 181B-FX test procedure).

Sherman, Max H.; Walker, Iain S.

2003-08-01T23:59:59.000Z

326

Duct Tape Durability Testing  

SciTech Connect (OSTI)

Duct leakage is a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums, or branches in the duct system. At each of these connections, a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have shown that taped seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory (LBNL) has been testing sealant durability for several years using accelerated test methods and found that typical duct tape (i.e., cloth-backed tapes with natural rubber adhesives) fails more rapidly than other duct sealants. This report summarizes the results of duct sealant durability testing over two years for four UL 181B-FX listed duct tapes (two cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The tests involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars. Periodic air leakage tests and visual inspection were used to document changes in sealant performance. After two years of testing, the flex-to-collar connections showed little change in air leakage, but substantial visual degradation from some products. A surprising experimental result was failure of most of the clamps used to mechanically fasten the connections. This indicates that the durability of clamps also need to be addressed ensure longevity of the duct connection. An accelerated test method developed during this study has been used as the basis for an ASTM standard (E2342-03).

Sherman, Max H.; Walker, Iain S.

2004-04-01T23:59:59.000Z

327

Standard test method for exfoliation corrosion susceptibility in 2XXX and 7XXX Series Aluminum Alloys (EXCO Test)  

E-Print Network [OSTI]

1.1 This test method covers a procedure for constant immersion exfoliation corrosion (EXCO) testing of high-strength 2XXX and 7XXX series aluminum alloys. Note 1—This test method was originally developed for research and development purposes; however, it is referenced, in specific material specifications, as applicable for evaluating production material (refer to Section 14 on Precision and Bias). 1.2 This test method applies to all wrought products such as sheet, plate, extrusions, and forgings produced from conventional ingot metallurgy process. 1.3 This test method can be used with any form of specimen or part that can be immersed in the test solution. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

American Society for Testing and Materials. Philadelphia

2007-01-01T23:59:59.000Z

328

Diesel Engine Idling Test  

SciTech Connect (OSTI)

In support of the Department of Energy’s FreedomCAR and Vehicle Technology Program Office goal to minimize diesel engine idling and reduce the consumption of millions of gallons of diesel fuel consumed during heavy vehicle idling periods, the Idaho National Laboratory (INL) conducted tests to characterize diesel engine wear rates caused by extended periods of idling. INL idled two fleet buses equipped with Detroit Diesel Series 50 engines, each for 1,000 hours. Engine wear metals were characterized from weekly oil analysis samples and destructive filter analyses. Full-flow and the bypass filter cartridges were removed at four stages of the testing and sent to an oil analysis laboratory for destructive analysis to ascertain the metals captured in the filters and to establish wear rate trends. Weekly samples were sent to two independent oil analysis laboratories. Concurrent with the filter analysis, a comprehensive array of other laboratory tests ascertained the condition of the oil, wear particle types, and ferrous particles. Extensive ferrogram testing physically showed the concentration of iron particles and associated debris in the oil. The tests results did not show the dramatic results anticipated but did show wear trends. New West Technologies, LLC, a DOE support company, supplied technical support and data analysis throughout the idle test.

Larry Zirker; James Francfort; Jordon Fielding

2006-02-01T23:59:59.000Z

329

Solution generating theorems: perfect fluid spheres and the TOV equation  

E-Print Network [OSTI]

We report several new transformation theorems that map perfect fluid spheres into perfect fluid spheres. In addition, we report new ``solution generating'' theorems for the TOV, whereby any given solution can be ``deformed'' to a new solution.

Petarpa Boonserm; Matt Visser; Silke Weinfurtner

2006-09-22T23:59:59.000Z

330

Jim Duckworth, WPI Verilog for Testing -Module 61 Test Benches (Test Fixtures)  

E-Print Network [OSTI]

Jim Duckworth, WPI Verilog for Testing - Module 61 Test Benches (Test Fixtures) Verilog for Testing #12;Jim Duckworth, WPI Verilog for Testing - Module 62 Overview · We have concentrated on Verilog for synthesis · Can also use Verilog as a test language · Very important to conduct comprehensive verification

Huang, Xinming

331

The Modified Sudden Death Test: Planning Life Tests with a Limited Number of Test Positions  

E-Print Network [OSTI]

The Modified Sudden Death Test: Planning Life Tests with a Limited Number of Test Positions Francis for Nondestructive Evaluation Iowa State University Ames, IA 50011 ABSTRACT: We present modified sudden death test (MSDT) plans to address the problem of limited testing positions in life tests. A single MSDT involves

332

The Modi ed Sudden Death Test: Planning Life Tests with a Limited Number of Test Positions  

E-Print Network [OSTI]

The Modi ed Sudden Death Test: Planning Life Tests with a Limited Number of Test Positions Francis for Nondestructive Evaluation Iowa State University Ames, IA 50011 ABSTRACT: We present modi ed sudden death test (MSDT) plans to address the problem of limited testing positions in life tests. A single MSDT involves

333

Architectures of Test Automation 1 High Volume Test AutomationHigh Volume Test Automation  

E-Print Network [OSTI]

Architectures of Test Automation 1 High Volume Test AutomationHigh Volume Test Automation Cem Kaner Institute of Technology October 2003 #12;Architectures of Test Automation 2 Acknowledgements developed a course on test automation architecture, and in the Los Altos Workshops on Software Testing

334

Five-Dimensional Cosmological Scaling Solution  

E-Print Network [OSTI]

A five-dimensional Ricci-flat cosmological solution is studied by assuming that the induced 4D matter contains two components: the usual fluid for dark matter as well as baryons and a scalar field with an exponential potential for dark energy. With use of the phase-plane analysis it is shown that there exist two late-time attractors one of which corresponds to a universe dominated by the scalar field alone and the other is a scaling solution in which the energy density of the scalar field remains proportional to that of the dark matter. It is furthermore shown that for this 5D scaling solution the universe expands with the same rate as in the 4D FRW models and not relies on which 4D hypersurface the universe is located in the 5D manifold.

Baorong Chang; Hongya Liu; Huanying Liu; Lixin Xu

2005-05-08T23:59:59.000Z

335

Building America Whole-House Solutions for New Homes: Transformations...  

Energy Savers [EERE]

Building America Whole-House Solutions for New Homes: Transformations, Inc. Net Zero Energy Communities (Fact Sheet) Building America Whole-House Solutions for New Homes:...

336

PIA - Savannah River Nuclear Solutions (SRNS) Human Resource...  

Office of Environmental Management (EM)

Solutions (SRNS) Human Resource Management System (HRMS) PIA - Savannah River Nuclear Solutions (SRNS) Human Resource Management System (HRMS) PIA - Savannah River Nuclear...

337

Cost Effectiveness of Technology Solutions for Future Vehicle...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Cost Effectiveness of Technology Solutions for Future Vehicle Systems Cost Effectiveness of Technology Solutions for Future Vehicle Systems Explores the economics of CO2 emission...

338

Coordination and Hydrolysis of Plutonium Ions in Aqueous Solution...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Hydrolysis of Plutonium Ions in Aqueous Solution using Car-Parrinello Molecular Dynamics Free Energy Coordination and Hydrolysis of Plutonium Ions in Aqueous Solution using...

339

Building America Technology Solutions for New and Existing Homes...  

Energy Savers [EERE]

Technology Solutions for New and Existing Homes: Buried and Encapsulated Ducts, Jacksonville, Florida (Fact Sheet) Building America Technology Solutions for New and Existing Homes:...

340

PIA - Savannah River Nuclear Solution SRNS ProRad Environment...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

SRNS ProRad Environment Management PIA - Savannah River Nuclear Solution SRNS ProRad Environment Management PIA - Savannah River Nuclear Solution SRNS ProRad Environment Management...

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

United States Department of Energy Solution Center for Renewable...  

Open Energy Info (EERE)

Solution Center for Renewable Energy and Energy Efficiency Jump to: navigation, search Tool Summary LAUNCH TOOL Name: United States Department of Energy Solution Center for...

342

Energy Department's New Buildings Solution Center Shares Proven...  

Office of Environmental Management (EM)

Department's New Buildings Solution Center Shares Proven Strategies for Energy Efficiency Programs Energy Department's New Buildings Solution Center Shares Proven Strategies for...

343

Formation of Supercooled Liquid Solutions from Nanoscale Amorphous...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Supercooled Liquid Solutions from Nanoscale Amorphous Solid Films of Methanol and Ethanol. Formation of Supercooled Liquid Solutions from Nanoscale Amorphous Solid Films of...

344

Probing the Degradation Mechanisms in Electrolyte Solutions for...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Degradation Mechanisms in Electrolyte Solutions for Li-ion Batteries by In-Situ Transmission Electron Microscopy. Probing the Degradation Mechanisms in Electrolyte Solutions for...

345

Building America Technology Solutions for New and Existing Homes...  

Energy Savers [EERE]

America Technology Solutions for New and Existing Homes: Foundation Heat Exchanger, Oak Ridge, Tennessee Building America Technology Solutions for New and Existing Homes:...

346

A Solution NMR Investigation into the Early Events of Amelogenin...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Solution NMR Investigation into the Early Events of Amelogenin Nanosphere Self-Assembly Initiated with Sodium Chloride or A Solution NMR Investigation into the Early Events of...

347

A solution NMR investigation into the impaired self-assembly...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

solution NMR investigation into the impaired self-assembly properties of two murine amelogenins containing the point mutations A solution NMR investigation into the impaired...

348

Electrodeposition From Acidic Solutions of Nickel Bis(benzenedithiolat...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

From Acidic Solutions of Nickel Bis(benzenedithiolate) Produces a Hydrogen-Evolving Ni-S Film on Glassy Carbon Electrodeposition From Acidic Solutions of Nickel...

349

Energy Storage Solutions Industrial Symposium | ornl.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy Storage Solutions Industrial Symposium Sep 04 2013 09:00 AM - 05:30 PM Energy Storage Solutions Industrial Symposium - Wednesday September 4, 2013 CONTACT : Email: Phone:...

350

Project Profile: CSP Energy Storage Solutions - Multiple Technologies...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Energy Storage Solutions - Multiple Technologies Compared Project Profile: CSP Energy Storage Solutions - Multiple Technologies Compared US Solar Holdings logo US Solar Holdings,...

351

Building America Technology Solutions for New and Existing Homes...  

Energy Savers [EERE]

Building America Technology Solutions for New and Existing Homes: Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes Building America Technology Solutions...

352

Breakout Session: Bringing Solutions to the Solar Industry: Startups...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Bringing Solutions to the Solar Industry: Startups, Technology Development and Market Entry Breakout Session: Bringing Solutions to the Solar Industry: Startups, Technology...

353

Innovative Financing Solutions: Finding Money for Your Energy...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Innovative Financing Solutions: Finding Money for Your Energy Efficiency Projects Innovative Financing Solutions: Finding Money for Your Energy Efficiency Projects Provides an...

354

PIA - Savannah River Nuclear Solutions Training Records and Informatio...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Nuclear Solutions Training Records and Information Network (TRAIN) PIA - Savannah River Nuclear Solutions Training Records and Information Network (TRAIN) PIA - Savannah River...

355

Building America Whole-House Solutions for Existing Homes: Passive...  

Broader source: Energy.gov (indexed) [DOE]

Whole-House Solutions for Existing Homes: Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet) Building America Whole-House Solutions for Existing Homes: Passive...

356

PIA - Savannah River Nuclear Solutions Badge Request and Site...  

Office of Environmental Management (EM)

Solutions Badge Request and Site Personnel Roster Systems PIA - Savannah River Nuclear Solutions Badge Request and Site Personnel Roster Systems PIA - Savannah River Nuclear...

357

Building America Whole-House Solutions for New Homes: Hydronic...  

Broader source: Energy.gov (indexed) [DOE]

Building America Whole-House Solutions for New Homes: Hydronic Heating Coil Versus Propane Furnace (Fact Sheet) Building America Whole-House Solutions for New Homes: Hydronic...

358

Test Anxiety Tips to Ease Your Test Anxiety  

E-Print Network [OSTI]

Test Anxiety Tips to Ease Your Test Anxiety Adapted from: Study Guides and Strategies website, Overcoming test anxiety Test taking can be overwhelming and can cause a lot of anxiety. Try these tips to ease your anxiety through the testing process! Before Approach the exam with confidence Be prepared

Kasman, Alex

359

Model-Based Testing : The Test of Formal Models  

E-Print Network [OSTI]

Model-Based Testing : The Test of Formal Models Jan Tretmans ESI & Radboud University Nijmegen #12;2 Testing (Software) Testing: checking or measuring some quality characteristics of an executing object by performing experiments in a controlled way w.r.t. a specification tester specification SUT System Under Test

360

Office of Evaluation and Testing Test Day Tips  

E-Print Network [OSTI]

Office of Evaluation and Testing Test Day Tips Get plenty of rest the night before the test. The best thing to do the evening before the test is to get a good night's sleep. You've covered the content and you've perfected the skills. Now it's time to get in test mode -- calm, rested, confident, and ready

Brinkmann, Peter

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Sparkr Blade Test Centre Fatigue tests of wind turbine blades  

E-Print Network [OSTI]

Sparkær Blade Test Centre Fatigue tests of wind turbine blades Flapwise fatigue tests of 3 blades wind load. By turning and oscillating the blade in the horzontal direction, an R-ratio of ­1 running at the Sparkær Centre Blade Test Facilities. Fatigue blade tests are performed in order

362

Corrosion testing using isotopes  

DOE Patents [OSTI]

A method is described for determining the corrosion behavior of a material with respect to a medium in contact with the material by: implanting a substantially chemically inert gas in a matrix so that corrosion experienced by the material causes the inert gas to enter the medium; placing the medium in contact with the material; and measuring the amount of inert gas which enters the medium. A test sample of a material whose resistance to corrosion by a medium is to be tested is described composed of: a body of the material, which body has a surface to be contacted by the medium; and a substantially chemically inert gas implanted into the body to a depth below the surface. A test sample of a material whose resistance to corrosion by a medium is to be tested is described composed of: a substrate of material which is easily corroded by the medium, the substrate having a surface; a substantially chemically inert gas implanted into the substrate; and a sheet of the material whose resistance to corrosion is to be tested, the sheet being disposed against the surface of the substrate and having a defined thickness. 3 figs.

Hohorst, F.A.

1995-12-05T23:59:59.000Z

363

Corrosion testing using isotopes  

DOE Patents [OSTI]

A method for determining the corrosion behavior of a material with respect to a medium in contact with the material by: implanting a substantially chemically inert gas in a matrix so that corrosion experienced by the material causes the inert gas to enter the medium; placing the medium in contact with the material; and measuring the amount of inert gas which enters the medium. A test sample of a material whose resistance to corrosion by a medium is to be tested, composed of: a body of the material, which body has a surface to be contacted by the medium; and a substantially chemically inert gas implanted into the body to a depth below the surface. A test sample of a material whose resistance to corrosion by a medium is to be tested, composed of: a substrate of material which is easily corroded by the medium, the substrate having a surface; a substantially chemically inert gas implanted into the substrate; and a sheet of the material whose resistance to corrosion is to be tested, the sheet being disposed against the surface of the substrate and having a defined thickness.

Hohorst, Frederick A. (Idaho Falls, ID)

1995-12-05T23:59:59.000Z

364

Radioluminescence of curium(III) in solutions  

SciTech Connect (OSTI)

The radioluminescence of curium(III) under the action of the intrinsic ..cap alpha..-radiation was studied in aqueous, heavy water, and organic solutions. The luminescence maximum falls at lambda approx. 600 nm. The yield of radioluminescence G is proportional to the concentration (or electronic fraction) of curium, and for a 10/sup -2/ M aqueous solution of Cm(NO/sub 3/)/sub 3/, G approx. 5 x 10/sup -4/ quanta per 100 eV of absorbed energy. In dilute acids the yield of radioluminescence is the same as in neutral solution, but in concentrated acid it is substantially changed. In the presence of ligands (formate, acetate, citrate ions, and others), the yield of the radioluminescence of curium in aqueous solutions increases, which is associated with complex formation, leading to a decrease in the quenching of excited curium by water molecules. The intensification of the radioluminescence of curium in the presence of sodium paratungstate is especially great; it is suggested that in this case a significant role is played by energy transfer from the ligand to curium. H/sub 2/O/sub 2/, NH/sub 2/NH/sub 2/, NH/sub 2/OH, Ce/sup (IV)/, and uranium, neptunium, and plutonium ions in various oxidation states have no great influence on the radioluminescence of curium. Its quenching by NpO/sub 2//sup +/ ions is somewhat greater than by other actinide ions and is associated with the formation of cation-cation complexes of NpO/sub 2//sup 2 +/ with Cm/sup 3 +/. In heavy water and organic solutions, a substantial increase in the radioluminescence yield of curium is observed, which is in good agreement with the data on photoluminescence. The results obtained suggest that the radioluminescence of curium in solutions (in the absence of energy-donor ligands) is excited mainly directly, while the role of energy transfer to curium from the solvent or its radiolysis products is negligible.

Yusov, A.B.; Perminov, V.P.; Krot, N.N.; Kazakov, V.P.

1987-01-01T23:59:59.000Z

365

Contrast enhancing solution for use in confocal microscopy  

DOE Patents [OSTI]

A method of optically detecting a tumor during surgery. The method includes imaging at least one test point defined on the tumor using a first optical imaging system to provide a first tumor image. The method further includes excising a first predetermined layer of the tumor for forming an in-vivo defect area. A predetermined contrast enhancing solution is disposed on the in-vivo defect area, which is adapted to interact with at least one cell anomaly, such as basal cell carcinoma, located on the in-vivo defect area for optically enhancing the cell anomaly. Thereafter the defect area can be optically imaged to provide a clear and bright representation of the cell anomaly to aid a surgeon while surgically removing the cell anomaly.

Tannous, Zeina; Torres, Abel; Gonzalez, Salvador

2006-10-31T23:59:59.000Z

366

Plutonium recovery from carbonate wash solutions  

SciTech Connect (OSTI)

Periodically higher than expected levels of plutonium are found in carbonate solutions used to wash second plutonium cycle solvent. The recent accumulation of plutonium in carbonate wash solutions has led to studies to determine the cause of that plutonium accumulation, to evaluate the quality of all canyon solvents, and to develop additional criteria needed to establish when solvent quality is acceptable. Solvent from three canyon solvent extraction cycles was used to evaluate technology required to measure tributyl phosphate (TBP) degradation products and was used to evaluate solvent quality criteria during the development of plutonium recovery processes. 1 fig.

Gray, J.H.; Reif, D.J.; Chostner, D.F.; Holcomb, H.P.

1991-12-31T23:59:59.000Z

367

Cosmological Solutions of Emergent Noncommutative Gravity  

SciTech Connect (OSTI)

Matrix models of the Yang-Mills type lead to an emergent gravity theory, which does not require fine-tuning of a cosmological constant. We find cosmological solutions of the Friedmann-Robertson-Walker type. They generically have a big bounce, and an early inflationlike phase with graceful exit. The mechanism is purely geometrical; no ad hoc scalar fields are introduced. The solutions are stabilized through vacuum fluctuations and are thus compatible with quantum mechanics. This leads to a Milne-like universe after inflation, which appears to be in remarkably good agreement with observation and may provide an alternative to standard cosmology.

Klammer, Daniela; Steinacker, Harold [Fakultaet fuer Physik, Universitaet Wien, A-1090 Wien (Austria)

2009-06-05T23:59:59.000Z

368

Alkali solution treatment on sandstone cores  

E-Print Network [OSTI]

was used for filtering the solution before the injection into the core. Hassler-t e Core Holder A stainless steel core holder was used to hold the core for treatment with the solutions. The core sample was positioned in the center of the core holder... and heat the water in the flask. Electric Heatin Ta e A silicone rubber embedded flexible heating tape was used to wrap the core holder to heat the core sample to the desired temperature. The maximum 0 continuous operating temperature of the tape...

Lee, Suk Jin

2012-06-07T23:59:59.000Z

369

Training & Technology Solutions Queens College ~ Office of Converging Technologies ~ Training & Technology Solutions  

E-Print Network [OSTI]

Training & Technology Solutions Queens College ~ Office of Converging Technologies ~ Training & Technology Solutions 718-997-4875 ~ training@qc.cuny.edu ~ I-Bldg 214 How to Pay Your Tuition Using E be navigated to your Student Center page. John Smith 23145678 John's Student Center #12;Training & Technology

Johnson Jr.,, Ray

370

Rotating equipment shop testing  

SciTech Connect (OSTI)

Poor performance of machinery after commissioning at first draws comments on whether the purchase specification was in order, whether there were any lapses in stage inspection or whether the performance test procedure was inadequate. Attempts are initiated to find out whether there were any deviations in operating conditions from the purchase specifications, inadvertent lapses in operation or any mistakes by the maintenance Dept. It will be of some interest to mention here a difference between operating companies who have taken over existing plants and engineering consulting companies who have engineered and constructed the plants. The specialist rotating machinery group of engineering consultant companies have a good understanding of what can be achieved at the manufacturer's test facility due to repeated dealings with manufacturers. However, operating company understanding varies from one organization to the next. This article gives an overview of rotating machinery with respect to test objectives and field problems.

Godse, A.G. (Kuwait National Petroleum Co., Shuaiba (KW))

1990-01-01T23:59:59.000Z

371

Removal of Pu238 from Neptunium Solution by Anion Exchange  

SciTech Connect (OSTI)

A new anion flowsheet for use in HB-Line was tested in the lab with Reillex{trademark} HPQ for removal of Pu{sup 238} contamination from Np. Significant rejection of Pu{sup 238} was observed by washing with 6 to 12 bed volumes (BV) of reductive wash containing reduced nitric acid concentration along with both ferrous sulfamate (FS) and hydrazine. A shortened-height column was utilized in these tests to match changes in the plant equipment. Lab experiments scaled to plant batch sizes of 1500 to 2200 g Np were observed with modest losses for up-flow washing. Down-flow washing was observed to have high losses. The following are recommended conditions for removing Pu{sup 238} from Np solutions by anion exchange in HB-Line: (1) Feed conditions: Up-flow 6.4-8 M HNO{sub 3}, 0.02 M hydrazine, 0.05 M excess FS, less than 5 days storage of solution after FS addition. (2) Reductive Wash conditions: Up-flow 6-12 BV of 6.4 M HNO{sub 3}, 0.05 M FS, 0.05 M hydrazine. 1.8 mL/min/cm{sup 2} flowrate. (3) Decontamination Wash conditions: Up-flow 1-2 BV of 6.4-8 M HNO{sub 3}, no FS, no hydrazine. (4) Elution conditions: Down-flow 0.17 M HNO{sub 3}, 0.05 M hydrazine, no FS.

KYSER, EDWARD

2003-12-01T23:59:59.000Z

372

Mining Test Cases To Improve Software Maintenance  

E-Print Network [OSTI]

Finding TestTracing Features to Test Cases . . . . . . . . . . . . . . .5.4.2 Finding Test Intents Using

Ziftci, Celal

373

NUMERICAL SOLUTION OF AN INVERSE OBSTACLE ...  

E-Print Network [OSTI]

radar and sonar, geophysical exploration, medical imaging, nondestructive testing ..... Let the measurement height h = 0.15? and noise level ? = 0 be fixed and ...

2014-09-30T23:59:59.000Z

374

Shedding light on LMA-Dark solar neutrino solution by medium baseline reactor experiments: JUNO and RENO-50  

E-Print Network [OSTI]

In the presence of Non-Standard neutral current Interactions (NSI) a new solution to solar neutrino anomaly with $\\cos 2\\theta_{12}<0$ appears. We investigate how this solution can be tested by upcoming intermediate baseline reactor experiments, JUNO and RENO-50. We point out a degeneracy between the two solutions when both hierarchy and the $\\theta_{12}$ octant are flipped. We then comment on how this degeneracy can be partially lifted by long baseline experiments sensitive to matter effects such as the NOvA experiment.

Pouya Bakhti; Yasaman Farzan

2014-07-02T23:59:59.000Z

375

RF test bench automation Description  

E-Print Network [OSTI]

RF test bench automation Description: Callisto would like to implement automated RF test bench. Three RF test benches have to be studied and automated: LNA noise temperature test bench LNA gain phase of the test benches and an implementation of the automation phase. Tasks: Noise temperature

Dobigeon, Nicolas

376

ONTOLOGY OF TEST Larisa Soldatova  

E-Print Network [OSTI]

ONTOLOGY OF TEST Larisa Soldatova Post doctoral researcher Riichiro Mizoguchi Professor ISIR, Osaka In the present paper design of test generation systems (TGS) based on test ontology and student's knowledge model parts: domain independent- and domain-dependant knowledge. Suggested test ontology allows analyzing test

Mizoguchi, Riichiro

377

Test Plan - Solids Accumulation Scouting Studies  

SciTech Connect (OSTI)

This plan documents the highlights of the Solids Accumulations Scouting Studies test; a project, from Washington River Protection Solutions (WRPS), that began on February 1, 2012. During the last 12 weeks considerable progress has been made to design and plan methods that will be used to estimate the concentration and distribution of heavy fissile solids in accumulated solids in the Hanford double-shell tank (DST) 241-AW-105 (AW-105), which is the primary goal of this task. This DST will be one of the several waste feed delivery staging tanks designated to feed the Pretreatment Facility (PTF) of the Waste Treatment and Immobilization Plant (WTP). Note that over the length of the waste feed delivery mission AW-105 is currently identified as having the most fill empty cycles of any DST feed tanks, which is the reason for modeling this particular tank. At SRNL an existing test facility, the Mixing Demonstration Tank, which will be modified for the present work, will use stainless steel particles in a simulant that represents Hanford waste to perform mock staging tanks transfers that will allow solids to accumulate in the tank heel. The concentration and location of the mock fissile particles will be measured in these scoping studies to produce information that will be used to better plan larger scaled tests. Included in these studies is a secondary goal of developing measurement methods to accomplish the primary goal. These methods will be evaluated for use in the larger scale experiments. Included in this plan are the several pretest activities that will validate the measurement techniques that are currently in various phases of construction. Aspects of each technique, e.g., particle separations, volume determinations, topographical mapping, and core sampling, have been tested in bench-top trials, as discussed herein, but the actual equipment to be employed during the full test will need evaluation after fabrication and integration into the test facility.

Duignan, M. R.; Steeper, T. J.; Steimke, J. L.; Fowley, M. D.

2012-05-10T23:59:59.000Z

378

Analysis of Alcove 8/Niche 3 Flow and Transport Tests  

SciTech Connect (OSTI)

The purpose of this report is to document analyses of the Alcove 8/Niche 3 flow and transport tests, with a focus on the large-infiltration-plot tests and compare pre-test model predictions with the actual test observations. The tests involved infiltration that originated from the floor of Alcove 8 (located in the Enhanced Characterization of Repository Block (ECRB) Cross Drift) and observations of seepage and tracer transport at Niche 3 (located in the Main Drift of the Exploratory Studies Facility (ESF)). The test results are relevant to drift seepage and solute transport in the unsaturated zone (UZ) of Yucca Mountain. The main objective of this analysis was to evaluate the modeling approaches used and the importance of the matrix diffusion process by comparing simulation and actual test observations. The pre-test predictions for the large plot test were found to differ from the observations and the reasons for the differences were documented in this report to partly address CR 6783, which concerns unexpected test results. These unexpected results are discussed and assessed with respect to the current baseline unsaturated zone radionuclide transport model in Sections 6.2.4, 6.3.2, and 6.4.

H.H. Liu

2006-09-01T23:59:59.000Z

379

Finding Acceptable Solutions Faster Using Inadmissible Information  

E-Print Network [OSTI]

explicit estimation search (EES), a bounded suboptimal search algorithm that uses unbiased cost(n)+h(n) becomes f (n) = g(n)+w·h(n). The weight, w, increases the importance of h (estimated cost of reaching attempt to find a solution quickly while guaranteeing that its cost does not exceed optimal by more than

Ruml, Wheeler

380

Energy and Society Week 3 Section Solution  

E-Print Network [OSTI]

Wh and the power plant has a conversion efficiency of 30%. Coal has an energy density of 29.3x106 J/kg. Before1 9/7/2014 Energy and Society Week 3 Section Solution 3. ENERGY BASICS AND UNIT ANALYSIS (ONLY to office hours soon. Energy versus Power - Work refers to an activity involving a force and movement

Kammen, Daniel M.

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Workshop to Assess Innovative Solutions to Transportation  

E-Print Network [OSTI]

Workshop to Assess Innovative Solutions to Transportation Needs in the Colonias Workshop Summary SWUTC/04/167151-1 Texas Transportation Institute Texas A&M University System College Station, Texas 77843-3135 Center for HUD's Colonias Program Southwest Region University Transportation Center #12

382

Schwarzschild solution in extended teleparallel gravity  

E-Print Network [OSTI]

Tetrad field, with two unknown functions of radial coordinate and an angle $\\Phi$ which is the polar angle $\\phi$ times a function of the redial coordinate, is applied to the field equation of modified theory of gravity. Exact vacuum solution is derived whose scalar torsion, $T ={T^\\alpha}_{\\mu \

G. G. L. Nashed

2015-01-05T23:59:59.000Z

383

Ankndigung Stellenausschreibung Forschungsprojekt Offshore-Solutions  

E-Print Network [OSTI]

Ankündigung Stellenausschreibung für das Forschungsprojekt Offshore-Solutions - Dienstleistungspotenziale von Werften und Reedereien als Lösungsanbieter während des Betriebs von Offshore Windparks und Reedereien in der Betriebsphase von Offshore-Windparks, ggf. bis zu einer Positionierung als

Berlin,Technische Universität

384

Piping-System Solutions Using Mathcad  

E-Print Network [OSTI]

Piping-System Solutions Using Mathcad B. K. HODGE,1 ROBERT P. TAYLOR2 1 Mechanical Engineering associated with piping systems. Examples include series piping systems, parallel piping systems, and pipingScience (www.interscience.wiley.com.); DOI 10.1002/cae.10010 Keywords: piping systems; Mathcad, Hardy

Kostic, Milivoje M.

385

EPSILON AURIGAE: AN IMPROVED SPECTROSCOPIC ORBITAL SOLUTION  

E-Print Network [OSTI]

A rare eclipse of the mysterious object ? Aurigae will occur in 2009-2011. We report an updated single-lined spectroscopic solution for the orbit of the primary star based on 20 years of monitoring at the CfA, combined ...

Stefanik, Robert P.

386

Robust capacity expansion solutions for telecommunication ...  

E-Print Network [OSTI]

networksX the ™osts of investment —nd the qu—lity of servi™e @ oƒA ...... Robust solutions with 1 ? ? for capacity constraints. Deterministic. Protection ...... tions networks under dem—nd un™ert—intyD in Proceedings of the 6th International.

2010-08-03T23:59:59.000Z

387

Exercise Session 6 (with solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 6 (with solutions) Alessandro Abate a.abate@tudelft.nl Marco Forgione m Session 6 ­ sc4026 #12;A. Abate, M. Forgione Linear Quadratic Regulator, in Theory Consider an object ­ Ac.Yr. 2012/13, 1e Sem. Q1 ­ Exercise Session 6 ­ sc4026 1 #12;A. Abate, M. Forgione it can be easily

Abate, Alessandro

388

Exercise Session 2 (with solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 2 (with solutions) Alessandro Abate a.abate@tudelft.nl Pawel Stano p ­ Exercise Session 2 ­ sc4026 #12;A. Abate, P. Stano Review of Eigenvalues and Eigenvectors Computation Find 1 #12;A. Abate, P. Stano The eigenvectors are found as follows: = 3 : (A - 3I)v = 0 -2 -2 2 -1

Abate, Alessandro

389

Exercise Session 2 (with solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 2 (with solutions) Alessandro Abate a.abate@tudelft.nl Jacopo Antonello j ­ Exercise Session 2 ­ sc4026 #12;A. Abate, J. Antonello Review of Eigenvalues and Eigenvectors Computation 1 #12;A. Abate, J. Antonello The eigenvectors are found as follows: = 3 : (A - 3I)v = 0 -2 -2 2

Abate, Alessandro

390

Exercise Session 3 (with solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 3 (with solutions) Alessandro Abate a.abate@tudelft.nl Marco Forgione m ­ Exercise Session 3 ­ sc4026 #12;A. Abate, M. Forgione Linearization Example In the following diagram, we.Yr. 2012/13, 1e Sem. Q1 ­ Exercise Session 3 ­ sc4026 1 #12;A. Abate, M. Forgione · x, horizontal position

Abate, Alessandro

391

Exercise Session 3 (with solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 3 (with solutions) Alessandro Abate a.abate@tudelft.nl Pawel Stano p ­ Exercise Session 3 ­ sc4026 #12;A. Abate, P. Stano Linearization Example In the following diagram, we have.Yr. 2011/12, 1e Sem. Q1 ­ Exercise Session 3 ­ sc4026 1 #12;A. Abate, P. Stano · x, horizontal position

Abate, Alessandro

392

Exercise Session 5 (with solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 5 (with solutions) Alessandro Abate a.abate@tudelft.nl Aleksandar Haber a Session 5 ­ sc4026 #12;A. Abate, P. Stano Eigenvalue Assignment via Controllable Canonical Form Consider ­ sc4026 1 #12;A. Abate, P. Stano The state space representation is: x1 x2 x3 x4 = -1 -2 -3

Abate, Alessandro

393

Exercise Session 5 (with solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 5 (with solutions) Alessandro Abate a.abate@tudelft.nl Jacopo Antonello j Session 5 ­ sc4026 #12;A. Abate, J. Antonello Eigenvalue Assignment via Controllable Canonical Form ­ sc4026 1 #12;A. Abate, J. Antonello The state space representation is: x1 x2 x3 x4 = -1

Abate, Alessandro

394

cleanenergyfuels.com Natural Gas Solutions  

E-Print Network [OSTI]

1 cleanenergyfuels.com Natural Gas Solutions for Transportation December 7, 2012 #12;2 cleanenergyfuels.com Compressed Natural Gas (CNG) Taxis Airport Vehicles Transit Buses Leading Provider of Natural Gas As a Transportation Fuel About Clean Energy Liquefied Natural Gas (LNG) Port Trucking LNG Station

Minnesota, University of

395

Semi-analytical solutions for multilayer reservoirs  

E-Print Network [OSTI]

Intercept Case 3 aj + bj tD Linear p[wDj(tD)] Case 4 a[j] exp(bj tD) Exponential p[wDj(tD)] Case 5 General formulation: p[wsD(tD)] = [] Total Pressure/Rate Averaging} Our work illustrates the validity of each approximate multilayer solution...

Lolon, Elyezer Pabibak

2012-06-07T23:59:59.000Z

396

Primes Solutions Of Linear Diophantine Equations  

E-Print Network [OSTI]

Let k => 1, m => 1 be small fixed integers, gcd(k, m) = 1. This note develops some techniques for proving the existence of infinitely many primes solutions x = p, and y = q of the linear Diophantine equation y = mx + k.

N. A. Carella

2014-04-03T23:59:59.000Z

397

On unorthodox solutions of the Bloch equations  

E-Print Network [OSTI]

A systematic, rigorous, and complete investigation of the Bloch equations in time-harmonic driving classical field is performed. Our treatment is unique in that it takes full advantage of the partial fraction decomposition over real number field, which makes it possible to find and classify all analytic solutions. Torrey's analytic solution in the form of exponentially damped harmonic oscillations [Phys. Rev. {\\bf 76}, 1059 (1949)] is found to dominate the parameter space, which justifies its use at numerous occasions in magnetic resonance and in quantum optics of atoms, molecules, and quantum dots. The unorthodox solutions of the Bloch equations, which do not have the form of exponentially damped harmonic oscillations, are confined to rather small detunings $\\delta^2\\lesssim (\\gamma-\\gamma_t)^2/27$ and small field strengths $\\Omega^2\\lesssim 8 (\\gamma-\\gamma_t)^2/27$, where $\\gamma$ and $\\gamma_t$ describe decay rates of the excited state (the total population relaxation rate) and of the coherence, respectively. The unorthodox solutions being readily accessible experimentally are characterized by rather featureless time dependence.

Alexander Moroz

2012-08-22T23:59:59.000Z

398

Energy and Society Week 4 Section Solution  

E-Print Network [OSTI]

. What is the main flaw of GDP per capita as the development metric? ANS: Open end question. Main flaw1 9/17/2014 Energy and Society Week 4 Section Solution TOPIC 1: Energy & Development: [iClicker]-1. Influence = B. Energy consumption = (/$) C. Carbon = 2 (/) ANS: [C] Note carbon

Kammen, Daniel M.

399

Storage Solutions for Hawaii's Smart Energy  

E-Print Network [OSTI]

Storage Solutions for Hawaii's Smart Energy Future Presented to CMRU August 12, 2012 University of Hawaii at Manoa Hawaii Natural Energy Institute #12;Current Energy Storage Projects in Hawaii · 15 (2) · Spinning reserve/reserve support (2) #12;· Select and deploy Grid-scale energy storage systems

400

Bifurcation to vortex solutions in superconducting lms  

E-Print Network [OSTI]

Bifurcation to vortex solutions in superconducting #12;lms T. Boeck #3; S.J. Chapman y Mathematical state to a superconducting state in a decreasing magnetic #12;eld is studied for a slab geometry of these behaviours will occur in practice. 1 Introduction If a superconducting body is placed in a suÃ?ciently strong

Chapman, Jon

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Annual Inventory Troubleshooting Checklist Problem Solutions  

E-Print Network [OSTI]

Annual Inventory Troubleshooting Checklist Problem Solutions Duplicate tag number Send email to am-4608 showing date and why returned. If equipment was replaced, has it been inventoried? If so, please notate and property coordinator. If item is listed for another department: 1) If the item should be in your inventory

402

Internship Description Title: Stellar Solutions Engineering Internship  

E-Print Network [OSTI]

Internship Description Title: Stellar Solutions ­ Engineering Internship Job Description: The internship will be held at the Stellar National Reconnaissance Office in Washington, DC. Tasks will require a background in intelligence, and familiar with all-source analysis. This internship is flexible throughout

Virginia Tech

403

Four nontrivial solutions for subcritical exponential equations  

E-Print Network [OSTI]

Four nontrivial solutions for subcritical exponential equations Dimitri Mugnai Dipartimento di@dipmat.unipg.it Abstract We show that a semilinear Dirichlet problem in bounded domains of R2 in presence of subcritical). Equation (3) is a standard example of a subcritical growth, while equation (4) is the model for a critical

Mugnai, Dimitri

404

CIMFUELS: Commercial practice--tools vs. solutions  

SciTech Connect (OSTI)

Continuing the them of CIMFUELS` recent editorials on good management practice, the nature of commercial offerings and practices between CIM providers and their fuel and petrochemical operating company customers and clients also warrants discussion. The commercial practices of the CIMFUELS business in this unstructured, fast changing, high technology global business has suffered unduly from inadequate distinction between tools and solutions.

Latour, P.R.

1997-03-01T23:59:59.000Z

405

Solution generating theorems for perfect fluid spheres  

E-Print Network [OSTI]

The first static spherically symmetric perfect fluid solution with constant density was found by Schwarzschild in 1918. Generically, perfect fluid spheres are interesting because they are first approximations to any attempt at building a realistic model for a general relativistic star. Over the past 90 years a confusing tangle of specific perfect fluid spheres has been discovered, with most of these examples seemingly independent from each other. To bring some order to this collection, we develop several new transformation theorems that map perfect fluid spheres into perfect fluid spheres. These transformation theorems sometimes lead to unexpected connections between previously known perfect fluid spheres, sometimes lead to new previously unknown perfect fluid spheres, and in general can be used to develop a systematic way of classifying the set of all perfect fluid spheres. In addition, we develop new ``solution generating'' theorems for the TOV, whereby any given solution can be ``deformed'' to a new solution. Because these TOV-based theorems work directly in terms of the pressure profile and density profile it is relatively easy to impose regularity conditions at the centre of the fluid sphere.

Petarpa Boonserm; Matt Visser; Silke Weinfurtner

2006-09-20T23:59:59.000Z

406

Solution generating theorems for the TOV equation  

E-Print Network [OSTI]

The Tolman-Oppenheimer-Volkov [TOV] equation constrains the internal structure of general relativistic static perfect fluid spheres. We develop several "solution generating" theorems for the TOV, whereby any given solution can be "deformed" to a new solution. Because the theorems we develop work directly in terms of the physical observables -- pressure profile and density profile -- it is relatively easy to check the density and pressure profiles for physical reasonableness. This work complements our previous article [Phys. Rev. D71 (2005) 124307; gr-qc/0503007] wherein a similar "algorithmic" analysis of the general relativistic static perfect fluid sphere was presented in terms of the spacetime geometry -- in the present analysis the pressure and density are primary and the spacetime geometry is secondary. In particular, our "deformed" solutions to the TOV equation are conveniently parameterized in terms of delta rho_c and delta p_c, the finite shift in the central density and central pressure. We conclude by presenting a new physical and mathematical interpretation of the TOV equation -- as an integrability condition on the density and pressure profiles.

Petarpa Boonserm; Matt Visser; Silke Weinfurtner

2007-07-17T23:59:59.000Z

407

Advanced Vehicle Testing Activity (AVTA) - Vehicle Testing and...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Advanced Vehicle Testing Activity (AVTA) Non-PHEV Evaluations and Data Collection AVTA HEV, NEV, BEV and HICEV Demonstrations and Testing Benchmarking of Advanced HEVs and...

408

Test Facility Daniil Stolyarov, Accelerator Test Facility User...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Development of the Solid-State Laser System for the Accelerator Test Facility Daniil Stolyarov, Accelerator Test Facility User's Meeting April 3, 2009 Outline Motivation for...

409

Micromachine friction test apparatus  

DOE Patents [OSTI]

A microelectromechanical (MEM) friction test apparatus is disclosed for determining static or dynamic friction in MEM devices. The friction test apparatus, formed by surface micromachining, is based on a friction pad supported at one end of a cantilevered beam, with the friction pad overlying a contact pad formed on the substrate. A first electrostatic actuator can be used to bring a lower surface of the friction pad into contact with an upper surface of the contact pad with a controlled and adjustable force of contact. A second electrostatic actuator can then be used to bend the cantilevered beam, thereby shortening its length and generating a relative motion between the two contacting surfaces. The displacement of the cantilevered beam can be measured optically and used to determine the static or dynamic friction, including frictional losses and the coefficient of friction between the surfaces. The test apparatus can also be used to assess the reliability of rubbing surfaces in MEM devices by producing and measuring wear of those surfaces. Finally, the friction test apparatus, which is small in size, can be used as an in situ process quality tool for improving the fabrication of MEM devices.

deBoer, Maarten P. (Albuquerque, NM); Redmond, James M. (Albuquerque, NM); Michalske, Terry A. (Cedar Crest, NM)

2002-01-01T23:59:59.000Z

410

Audiometry (hearing test)  

Broader source: Energy.gov [DOE]

The audiogram is an evaluation of how well an individual can hear. Sounds are presented to the individual through earphones during the test. These sounds are presented at different levels of frequency and intensity. The human ear responds to the frequency or pitch of a sound and the intensity or loudness of the sound.

411

Alfalfa Seed Testing.  

E-Print Network [OSTI]

Texas Agricultural Experiment Stations -- - - -- - - - -- - -- Bulletin - No. 81 BOTANICAL SECTION. DECEMBER, 1905. Alfalfa Seed Testing By 0. M. BALL. Postoff ice: College Station, Brazos County, Texas. TEXAS AGRICULTURAL EXPERIMENT... ...................................... 4 Goocl Alfalfa Seed ...................................... 4 Method of Examining for Purity ........................ 6 Weed Seeds Often Found in Alfalfa ...................... 6 Russian Thistles .................................. 7 Ribdrass...

Ball, O. M. (Oscar Melville)

1905-01-01T23:59:59.000Z

412

Proceedings IEEE International Test Conference, Charlotte, NC, USA, September 30 October 2, 2003 A HYBRID CODING STRATEGY FOR  

E-Print Network [OSTI]

Proceedings IEEE International Test Conference, Charlotte, NC, USA, September 30 ­ October 2, 2003-fold solution: (1) The test data volume can be greatly reduced by simple encoding and decoding procedures. (2 A HYBRID CODING STRATEGY FOR OPTIMIZED TEST DATA COMPRESSION Armin Würtenberger, Christofer S. Tautermann

Hellebrand, Sybille

413

Specific test and evaluation plan  

SciTech Connect (OSTI)

The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made to the 241-AX-B Valve Pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.

Hays, W.H.

1998-03-20T23:59:59.000Z

414

Transition-fault test generation  

E-Print Network [OSTI]

. One way to detect these timing defects is to apply test patterns to the integrated circuit that are generated using the transition-fault model. Unfortunately, industry's current transition-fault test generation schemes produce test sets that are too...

Cobb, Bradley Douglas

2013-02-22T23:59:59.000Z

415

Clean Energy Solutions Center Services (Chinese Translation) (Fact Sheet)  

SciTech Connect (OSTI)

This is the Chinese language translation of the Clean Energy Solutions Center (Solutions Center) fact sheet. The Solutions Center helps governments, advisors and analysts create policies and programs that advance the deployment of clean energy technologies. The Solutions Center partners with international organizations to provide online training, expert assistance, and technical resources on clean energy policy.

Not Available

2014-04-01T23:59:59.000Z

416

Clean Energy Solutions Center Services (Vietnamese Translation) (Fact Sheet)  

SciTech Connect (OSTI)

This is the Vietnamese language translation of the Clean Energy Solutions Center (Solutions Center) fact sheet. The Solutions Center helps governments, advisors and analysts create policies and programs that advance the deployment of clean energy technologies. The Solutions Center partners with international organizations to provide online training, expert assistance, and technical resources on clean energy policy.

Not Available

2014-11-01T23:59:59.000Z

417

Clean Energy Solutions Center Services (Arabic Translation) (Fact Sheet)  

SciTech Connect (OSTI)

This is the Arabic translation of the Clean Energy Solutions Center Services fact sheet. The Clean Energy Solutions Center (Solutions Center) helps governments, advisors and analysts create policies and programs that advance the deployment of clean energy technologies. The Solutions Center partners with international organizations to provide online training, expert assistance, and technical resources on clean energy policy.

Not Available

2014-06-01T23:59:59.000Z

418

Symmetry in CSP solutions Nicoleta Neagu and Boi Faltings  

E-Print Network [OSTI]

Symmetry in CSP solutions Nicoleta Neagu and Boi Faltings Artificial Intelligence Laboratory (LIA for finding symmetric solutions of in a CSP. This method is using local symmetries of the CSP structure and research upon searching CSP solutions but few of them watch the relations between CSP solutions. In certain

Flener, Pierre

419

Static Solutions of Einstein's Equations with Spherical Symmetry  

E-Print Network [OSTI]

The Schwarzschild solution is a complete solution of Einstein's field equations for a static spherically symmetric field. The Einstein's field equations solutions appear in the literature, but in different ways corresponding to different definitions of the radial coordinate. We attempt to compare them to the solutions with nonvanishing energy density and pressure. We also calculate some special cases with changes in spherical symmetry.

Iftikhar Ahmad; Maqsoom Fatima; Najam-ul-Basat

2014-05-02T23:59:59.000Z

420

GAP TESTS; COMPARISON BETWEEN UN GAP TEST AND CARD GAP TEST  

E-Print Network [OSTI]

98-36 GAP TESTS; COMPARISON BETWEEN UN GAP TEST AND CARD GAP TEST by R. BRANKA and C. MICHOT, FRANCE (tel.: 33 3 44 55 65 19, fax: 33 3 44 55 65 10) ABSTRACT: UN gap test, type 1(a) or 2(a), is the recommended test in the acceptance procedure for transport of explosives in class 1. Up to the revision

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Copyright (c) Cem Kaner, Automated Testing. 1 Software Test Automation:Software Test Automation  

E-Print Network [OSTI]

Copyright (c) Cem Kaner, Automated Testing. 1 Software Test Automation:Software Test Automation: A RealA Real--World ProblemWorld Problem Cem Kaner, Ph.D., J.D. #12;Copyright (c) Cem Kaner, Automated Testing. 2 This TalkThis Talk The most widely used class of automated testing tools leads senior software

422

Turing test: an historical perspective  

SciTech Connect (OSTI)

This article explains the turing test of machine intelligence. This test has become the accepted criteria for defining a computer as truly intelligent.

Ahl, D.H.

1983-08-01T23:59:59.000Z

423

SPECTR System Operational Test Report  

SciTech Connect (OSTI)

This report overviews installation of the Small Pressure Cycling Test Rig (SPECTR) and documents the system operational testing performed to demonstrate that it meets the requirements for operations. The system operational testing involved operation of the furnace system to the design conditions and demonstration of the test article gas supply system using a simulated test article. The furnace and test article systems were demonstrated to meet the design requirements for the Next Generation Nuclear Plant. Therefore, the system is deemed acceptable and is ready for actual test article testing.

W.H. Landman Jr.

2011-08-01T23:59:59.000Z

424

AVTA ? PHEV Demonstrations and Testing  

Broader source: Energy.gov (indexed) [DOE]

using dedicated drivers and other methods to accumulate miles and cycles - Fleet testing, uses unstructured vehicle utilization - Different testing methods are used to balance...

425

Laser-Based Nondestructive Testing  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Laser-Based Nondestructive Testing High speed, non-contact NDT for bridging the gap between traditional nondestructive testing and embedded structural health monitoring. Contact...

426

Predictive Control of a Boeing 747 Aircraft using an FPGA  

E-Print Network [OSTI]

are reconfigurable chips that can be customised for a specific application and have the potential to address all of these problems. For this class of devices, transistor scaling is still improving the performance and reducing the cost in every new technology... is min ? ? (?xN ? ?x?) ? 2 P + N?1? k=0 ( ? (?xk ? ?x?) ? 2 Q + ? (?uk ? ?u?) ? 2 R ) (3a) subject to ?x0 = ?xˆ(k) (from observer) (3b) ?xk+1 = A?xk +B?uk +Bdwˆ(k), k ? 0, . . . , N ? 1 (3c) ?umin ? ?uk ? ?umax k ? 0, . . . , N ? 1. (3d) For simplicity...

Hartley, Edward N.; Jerez, Juan L.; Suardi, Andrea; Maciejowski, Jan M.; Kerrigan, Eric C.; Constantinides, George A.

2012-08-24T23:59:59.000Z

427

Sandia National Laboratories: ECIS, Boeing, Caltrans, and Others:  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassive SolarEducation Programs:CRFProvide InsightSystemsNuclearFuel-Cell-Powered

428

File:EIA-BlackWarrior-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 2010 Thumbnailpixels. Full resolution

429

File:EIA-Denver-Mid-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 2010 Thumbnailpixels. FullFile

430

File:EIA-Denver-N-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 2010 Thumbnailpixels.December 2010

431

File:EIA-Denver-S-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 2010 Thumbnailpixels.December 201096,600

432

File:EIA-FL-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100 December 2010 1,650 × 1,275MB,

433

File:EIA-GGR-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100 December 2010 1,650 ×SouthGreater

434

File:EIA-MTB-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100 December 2010 1,650Greater

435

File:EIA-PRB-N-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100 December 2010Montana Thrust

436

File:EIA-PRB-S-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100 December 2010MontanaLiquidsPowder

437

File:EIA-PSJ-NW-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100 DecemberPowder River

438

File:EIA-PSJ-SE-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100 DecemberPowder

439

File:EIA-UP-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100 DecemberPowderGAS.pdf

440

File:EIA-Ventura-E-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100UP-LIQ.pdf Jump to:

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

File:EIA-WTB-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100UP-LIQ.pdf Jumpliquids.pdfWyoming

442

File:EIA-Williston-NW-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100UP-LIQ.pdfWyoming ThrustWilliston

443

File:EIA-Williston-S-BOE.pdf | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdf JumpApschem.pdf Jump to:December 20100UP-LIQ.pdfWyomingWilliston

444

The Boeing Company Smart Grid Demonstration Project | Open Energy  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to:Seadov Pty LtdSteen,Ltd Jump Jump to:Information 'Grand Paris' Project:Beam Jump

445

Semiconductor Bridge Cable Test  

SciTech Connect (OSTI)

The semiconductor bridge (SCB) is an electroexplosive device used to initiate detonators. A C cable is commonly used to connect the SCB to a firing set. A series of tests were performed to identify smaller, lighter cables for firing single and multiple SCBs. This report provides a description of these tests and their results. It was demonstrated that lower threshold voltages and faster firing times can be achieved by increasing the wire size, which reduces ohmic losses. The RF 100 appears to be a reasonable substitute for C cable when firing single SCBs. This would reduce the cable volume by 68% and the weight by 67% while increasing the threshold voltage by only 22%. In general, RG 58 outperforms twisted pair when firing multiple SCBs in parallel. The RG 58's superior performance is attributed to its larger conductor size.

KING, TONY L.

2002-01-01T23:59:59.000Z

446

Test fire environmental testing operations at Mound Applied Technologies  

SciTech Connect (OSTI)

This paper describes Mound Laboratory`s environmental testing operations. The function of environmental testing is to perform quality environmental (thermal, mechanical, spin, resistance, visual) testing/conditioning of inert/explosive products to assure their compliance with specified customer acceptance criteria. Capabilities, organization, equipment specifications, and test facilities are summarized.

NONE

1992-03-01T23:59:59.000Z

447

Software Verification and Testing Lecture Notes: Testing I  

E-Print Network [OSTI]

Software Verification and Testing Lecture Notes: Testing I #12;Motivation verification: · powerful · automated techniques rather limited testing: (as "poor man's verification") · can only detect presence mathematical skills 1 #12;Motivation verification vs testing: · verification used often in early stages

Struth, Georg

448

Test Access Mechanism Optimization, Test Scheduling, and Tester Data Volume  

E-Print Network [OSTI]

Test Access Mechanism Optimization, Test Scheduling, and Tester Data Volume Reduction for System Marinissen, Senior Member, IEEE Abstract--We describe an integrated framework for system-on-chip (SOC) test automation. Our framework is based on a new test access mechanism (TAM) architecture consisting of flexible

Chakrabarty, Krishnendu

449

INVERSE-SQUARE LAW TESTS 1 TESTS OF THE GRAVITATIONAL  

E-Print Network [OSTI]

INVERSE-SQUARE LAW TESTS 1 TESTS OF THE GRAVITATIONAL INVERSE-SQUARE LAW E.G.Adelberger, B-1560 KEYWORDS: gravitation, experimental tests of inverse-square law, quantum gravity, extra dimensions ABSTRACT: We review recent experimental tests of the gravitational inverse-square law, and the wide variety

Washington at Seattle, University of - Department of Physics, Electroweak Interaction Research Group

450

Sparkr Blade Test Centre Static tests of wind turbine blades  

E-Print Network [OSTI]

Sparkær Blade Test Centre Static tests of wind turbine blades Static blade tests are performed-4000 Roskilde Denmark www.risoe.dk Wind Energy Department Sparkær Blade test Centre vea@risoe.dk Tel in order to determine the structural properties of a blade including stiffness data and strain distribution

451

Test factoring with amock: generating readable unit tests from system tests  

E-Print Network [OSTI]

Automated unit tests are essential for the construction of reliable software, but writing them can be tedious. If the goal of test generation is to create a lasting unit test suite (and not just to optimize execution of ...

Glasser, David Samuel

2007-01-01T23:59:59.000Z

452

Testing Bulls for Fertility.  

E-Print Network [OSTI]

, but this seasonal dif- ference is not shown by the survey. However, there is a trend toward lower fertility in late summer if the questionable bulls are included with the cull bulls. funnel which reduces breakage and hjui The reproductive organs should... OF THE TESTS --------_-_ 6 Sa~isfactor~ ............................ 6 Questionable ........................... 6 Cull ................................... 6 WHEN TO CHECK FOR FERTILITY -_-_-_----_-- 6 Just Before the Breeding Season ----_--_-_- 6 Soon...

Berry, R. O.; Thompson, U. D.; Sorensen, A. M.; Maddox, L. A. Jr.

1958-01-01T23:59:59.000Z

453

Grayloc seal static tests  

SciTech Connect (OSTI)

A series of evaluation tests was performed on Grayloc seals. Helium service and standard seals, size 292, were used. Measurements were made of axial force and motion, diameter, hoop and axial strain, and helium leak rate. Leak rates were in the 10/sup -6/ atm cc/s range for the helium service seals. Pretest analytical calculations agreed reasonably well with measured makeup forces and deflections.

Leisher, W.B.; Biffle, J.H.

1983-02-01T23:59:59.000Z

454

STK Bladestore Tests  

SciTech Connect (OSTI)

The STK Bladestore is a disk subsystem consisting of ATA disks, fiber channel connectivity, and a RAID controller (LSI manufactured). There are essentially four host connections and four backend fiber connections. The host side ports are 2Gb/sec and with their advertised 400MB/sec bandwidth, the disk side ports are 1GB/sec. Our goal is to test this flavor of disk to see what the real world performance might be.

Heer, T

2003-11-05T23:59:59.000Z

455

Solution-grown crystals for neutron radiation detectors, and methods of solution growth  

DOE Patents [OSTI]

A method according to one embodiment includes growing an organic crystal from solution, the organic crystal exhibiting a signal response signature for neutrons from a radioactive source. A system according to one embodiment includes an organic crystal having physical characteristics of formation from solution, the organic crystal exhibiting a signal response signature for neutrons from a radioactive source; and a photodetector for detecting the signal response of the organic crystal. A method according to another embodiment includes growing an organic crystal from solution, the organic crystal being large enough to exhibit a detectable signal response signature for neutrons from a radioactive source. An organic crystal according to another embodiment includes an organic crystal having physical characteristics of formation from solution, the organic crystal exhibiting a signal response signature for neutrons from a radioactive source, wherein the organic crystal has a length of greater than about 1 mm in one dimension.

Zaitseva, Natalia P.; Hull, Giulia; Cherepy, Nerine J.; Payne, Stephen A.; Stoeffl, Wolfgang

2012-06-26T23:59:59.000Z

456

System and method for laser assisted sample transfer to solution for chemical analysis  

DOE Patents [OSTI]

A system and method for laser desorption of an analyte from a specimen and capturing of the analyte in a suspended solvent to form a testing solution are described. The method can include providing a specimen supported by a desorption region of a specimen stage and desorbing an analyte from a target site of the specimen with a laser beam centered at a radiation wavelength (.lamda.). The desorption region is transparent to the radiation wavelength (.lamda.) and the sampling probe and a laser source emitting the laser beam are on opposite sides of a primary surface of the specimen stage. The system can also be arranged where the laser source and the sampling probe are on the same side of a primary surface of the specimen stage. The testing solution can then be analyzed using an analytical instrument or undergo further processing.

Van Berkel, Gary J; Kertesz, Vilmos

2014-01-28T23:59:59.000Z

457

Evaluation of the Magnesium Hydroxide Treatment Process for Stabilizing PFP Plutonium/Nitric Acid Solutions  

SciTech Connect (OSTI)

This document summarizes an evaluation of the magnesium hydroxide [Mg(OH)2] process to be used at the Hanford Plutonium Finishing Plant (PFP) for stabilizing plutonium/nitric acid solutions to meet the goal of stabilizing the plutonium in an oxide form suitable for storage under DOE-STD-3013-99. During the treatment process, nitric acid solutions bearing plutonium nitrate are neutralized with Mg(OH)2 in an air sparge reactor. The resulting slurry, containing plutonium hydroxide, is filtered and calcined. The process evaluation included a literature review and extensive laboratory- and bench-scale testing. The testing was conducted using cerium as a surrogate for plutonium to identify and quantify the effects of key processing variables on processing time (primarily neutralization and filtration time) and calcined product properties.

Gerber, Mark A.; Schmidt, Andrew J.; Delegard, Calvin H.; Silvers, Kurt L.; Baker, Aaron B.; Gano, Susan R.; Thornton, Brenda M.

2000-09-28T23:59:59.000Z

458

Solutions to the anisotropic quantum Rabi model  

E-Print Network [OSTI]

In this work, the anisotropic quantum Rabi model with different coupling strengths of the rotating-wave and counter-rotating wave terms is studied by using two kinds of extended coherent states (ECS). By the first kind of ECS, we can derive a so-called $G$-function, by which both the regular and exceptional solutions can be given. The exceptional solution are just corresponding to the crossing points of two energy levels with different parities, so is doubly degenerate. By the second kind of ECS, a general scheme for the eigensolutions is derived analytically in a unified way. The zero-order approximation is just the adiabatic approximation, and the first-order approximation is actually a generalized rotating-wave approximation. The algebraic formulae for the eigensolutions are given explicitly in two approximations. The generalized rotating-wave approximations work well in a wide range of two different coupling strengths and the qubit detunings.

Liwei Duan; Qing-Hu Chen

2015-02-02T23:59:59.000Z

459

Fractal powers in Serrin's swirling vortex solutions  

E-Print Network [OSTI]

We consider a modification of the fluid flow model for a tornado-like swirling vortex developed by J. Serrin, where velocity decreases as the reciprocal of the distance from the vortex axis. Recent studies, based on radar data of selected severe weather events, indicate that the angular momentum in a tornado may not be constant with the radius, and thus suggest a different scaling of the velocity/radial distance dependence. Motivated by this suggestion, we consider Serrin's approach with the assumption that the velocity decreases as the reciprocal of the distance from the vortex axis to the power $b$ with a general $b>0$. This leads to a boundary-value problem for a system of nonlinear differential equations. We analyze this problem for particular cases, both with nonzero and zero viscosity, discuss the question of existence of solutions, and use numerical techniques to describe those solutions that we cannot obtain analytically.

Pavel B?lík; Douglas P. Dokken; Kurt Scholz; Mikhail M. Shvartsman

2014-04-28T23:59:59.000Z

460

The Radiolysis of AmVI Solutions  

SciTech Connect (OSTI)

The reduction of bismuthate-produced AmVI by 60Co gamma-rays was measured using post-irradiation UV/Vis spectroscopy. The reduction of AmVI by radiolysis was rapid, producing AmV as the sole product. Relatively low absorbed doses in the ~0.3 kGy range quantitatively reduced a solution of 2.5 x 10-4 M AmVI. The addition of bismuthate to samples during irradiation did not appear to protect AmVI from radiolytic reduction during these experiments. It was also shown here that AmV is very stable toward radiation. The quantitative reduction of the AmVI concentration here corresponds to 1.4 hours of exposure to a process solution, however the actual americium concentrations will be higher and the expected contact times short when using centrifugal contactors. Thus, the reduction rate found in these initial experiments may not be excessive.

Bruce J. Mincher

2013-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Predicting binding free energies in solution  

E-Print Network [OSTI]

Recent predictions of absolute binding free energies of host-guest complexes in aqueous solution using electronic structure theory have been encouraging for some systems, while other systems remain problematic for others. In paper I summarize some of the many factors that could easily contribute 1-3 kcal/mol errors at 298 K: three-body dispersion effects, molecular symmetry, anharmonicity, spurious imaginary frequencies, insufficient conformational sampling, wrong or changing ionization states, errors in the solvation free energy of ions, and explicit solvent (and ion) effects that are not well-represented by continuum models. While the paper is primarily a synthesis of previously published work there are two new results: the adaptation of Legendre transformed free energies to electronic structure theory and a use of water clusters that maximizes error cancellation in binding free energies computed using explicit solvent molecules. While I focus on binding free energies in aqueous solution the approach also a...

Jensen, Jan H

2015-01-01T23:59:59.000Z

462

Alkaline earth cation extraction from acid solution  

DOE Patents [OSTI]

An extractant medium for extracting alkaline earth cations from an aqueous acidic sample solution is described as are a method and apparatus for using the same. The separation medium is free of diluent, free-flowing and particulate, and comprises a Crown ether that is a 4,4'(5')[C.sub.4 -C.sub.8 -alkylcyclohexano]18-Crown-6 dispersed on an inert substrate material.

Dietz, Mark (Elmhurst, IL); Horwitz, E. Philip (Naperville, IL)

2003-01-01T23:59:59.000Z

463

Model of Large Mixing Angle MSW Solution  

E-Print Network [OSTI]

We have obtained the neutrino mass matrix with the large mixing angle (LMA) MSW solution, $\\sin^2 2\\th_\\odot=0.65\\sim 0.97$ and $\\Delta m_{\\odot}^2= 10^{-5}\\sim 10^{-4}\\eV^2$, in the $S_{3L}\\times S_{3R}$ flavor symmetry. The structure of our neutrino mass matrix is found to be stable against radiative corrections.

Morimitsu Tanimoto

2000-02-15T23:59:59.000Z

464

Generating catalogs of transverse matching solutions  

SciTech Connect (OSTI)

Programs such as TRANSPORT or TRACE can find transverse beam matching solutions one at a time when given appropriate starting conditions. In the present work, an algorithm is described which rapidly finds a catalog of approximate transverse beam matching solutions. For a given initial beam, the algorithm finds the gradients of four quadrupole magnets such as to get four Twiss parameters (alpha and beta for horizontal and vertical planes) which are close to a set of desired values at the exit of a constant-energy beam line with no horizontal-vertical cross coupling and no space charge. The beam line may contain bending elements with edge corrections and other elements for which the r matrixes are known. The algorithm transforms the entrance and exit beam specifications to waist specifications, and uses the properties of waist-to-waist transport to reduce the problem from a four dimensional search to a two dimensional search. At the Los Alamos Meson Physics Facility (LAMPF) accelerator, transverse matching is important in the low-energy transport lines (0.75 MeV), where beams from the H/sup +/, H/sup /minus//, and polarized H/sup /minus// sources must be tailored for injection into the drift-tube linac; and in the transition region (100 MeV), where the beam from the drift-tube linac is injected into the side-coupled linac. Space charge has significant effects in the low-energy transport, but it is still valuable to get no-space-charge matching solutions as a starting point for solutions with space charge. 2 refs.

Swain, G.; Busch, P.; Burns, M.

1989-01-01T23:59:59.000Z

465

SOLUTIONS TO EXERCISE SET #4 SCOTT MESSICK  

E-Print Network [OSTI]

is a legal coloring if for each edge e E, |f(e)| > 1, i.e., there exist vertices u, v E such that f(u) = fSOLUTIONS TO EXERCISE SET #4 SCOTT MESSICK Exercise 4.1. (a) Define legal colorings of a hypergraph = (V, E) be a hypergraph. A coloring is a function f : V C where C is the set of "colors" (any set); f

Babai, László

466

Exercise Session 1 (with Solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 1 (with Solutions) Alessandro Abate a.abate@tudelft.nl Pawel Stano p ­ Exercise Session 1 ­ sc4026 #12;A. Abate, P. Stano State-Space Model Consider the third-order model d3q dt32 + 4x1 = u, y = x1. ­ Ac.Yr. 2011/12, 1e Sem. Q1 ­ Exercise Session 1 ­ sc4026 1 #12;A. Abate, P

Abate, Alessandro

467

Exercise Session 6 (with solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 6 (with solutions) Alessandro Abate a.abate@tudelft.nl Aleksandar Haber a Session 6 ­ sc4026 #12;A. Abate, A. Haber Linear Quadratic Regulator, in Theory Consider an object of mass ­ Ac.Yr. 2011/12, 1e Sem. Q1 ­ Exercise Session 6 ­ sc4026 1 #12;A. Abate, A. Haber it can be easily

Abate, Alessandro

468

Exercise Session 4 (with solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 4 (with solutions) Alessandro Abate a.abate@tudelft.nl Aleksandar Haber a Session 4­ sc4026 #12;A. Abate, A. Haber Lyapunov Stability Consider the planar system x = Ax = -2 0 0 -2 = 1 4(x2 1 + x2 2). 2 ­ Ac.Yr. 2011/12, 1e Sem. Q1 ­ Exercise Session 4­ sc4026 1 #12;A. Abate, A

Abate, Alessandro

469

Exercise Session 1 (with Solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 1 (with Solutions) Alessandro Abate a.abate@tudelft.nl Jacopo Antonello j ­ Exercise Session 1 ­ sc4026 #12;A. Abate, J. Antonello State-Space Model Consider the third-order model d3q2 + 4x1 = u, y = x1. ­ Ac.Yr. 2012/13, 1e Sem. Q1 ­ Exercise Session 1 ­ sc4026 1 #12;A. Abate, J

Abate, Alessandro

470

Exercise Session 4 (with solutions) Alessandro Abate  

E-Print Network [OSTI]

sc4026 Exercise Session 4 (with solutions) Alessandro Abate a.abate@tudelft.nl Jacopo Antonello j Session 4­ sc4026 #12;A. Abate, J. Antonello Lyapunov Stability Consider the planar system x = Ax = -2 0 0 = 1 4(x2 1 + x2 2). 2 ­ Ac.Yr. 2012/13, 1e Sem. Q1 ­ Exercise Session 4­ sc4026 1 #12;A. Abate, J

Abate, Alessandro

471

SolSolution | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating Solar PowerstoriesNrelPartnerTypePonsa, Mallorca:upGuidebookSolSolution Jump to:

472

Groom Energy Solutions | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy Resources Jump to: navigation,Ohio:Greer County is a county in Oklahoma.Groom Energy Solutions Jump to:

473

Island Energy Solutions | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating Solar Powerstories on climate compatibleInformation off gridEnergy Solutions Jump

474

Chevron Energy Solutions | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectricEnergyCTBarreisVolcanic National Park | OpenChevron Energy Solutions Jump

475

Composite Tower Solutions | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentratingRenewable Solutions LLC Jump to: navigation, search Name:CXD) Jump23TechnologyTower

476

ConEdison Solutions | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentratingRenewable Solutions LLC Jump to: navigation,Area (Keith, Et Al., 1992)Comverge Jump

477

Conservation Resource Solutions | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentratingRenewable Solutions LLC Jump to: navigation,AreaHighInformationConservation

478

Green Heat Solutions Limited | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy Resources Jump to: navigation,Ohio: EnergyGrasslands RenewableGreatwood,Green Energy WorldHabitsSolutions

479

Public Energy Solutions | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: EnergyPotentialUrbanUtilityScalePVCapacity Jump to:USGSMeanReservoirTemp JumpProterraIntegralesEnergy Solutions

480

Cleantech Solutions (Colorado) | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartmentAUDITOhioOglesby,Sullivan, MissouriWebsterElectric Coop CorpCleanLaunchSolutions

Note: This page contains sample records for the topic "testing solutions boeing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Chemical deposition methods using supercritical fluid solutions  

DOE Patents [OSTI]

A method for depositing a film of a desired material on a substrate comprises dissolving at least one reagent in a supercritical fluid comprising at least one solvent. Either the reagent is capable of reacting with or is a precursor of a compound capable of reacting with the solvent to form the desired product, or at least one additional reagent is included in the supercritical solution and is capable of reacting with or is a precursor of a compound capable of reacting with the first reagent or with a compound derived from the first reagent to form the desired material. The supercritical solution is expanded to produce a vapor or aerosol and a chemical reaction is induced in the vapor or aerosol so that a film of the desired material resulting from the chemical reaction is deposited on the substrate surface. In an alternate embodiment, the supercritical solution containing at least one reagent is expanded to produce a vapor or aerosol which is then mixed with a gas containing at least one additional reagent. A chemical reaction is induced in the resulting mixture so that a film of the desired material is deposited.

Sievers, Robert E. (Boulder, CO); Hansen, Brian N. (Boulder, CO)

1990-01-01T23:59:59.000Z

482

Hypersonic nonequilibrium Navier-Stokes solutions over an ablating graphite nosetip  

SciTech Connect (OSTI)

The general boundary conditions, including mass and energy balances, of chemically equilibrated or nonequilibrated gas adjacent to ablating surfaces have been derived. A computer procedure based on these conditions was developed and interfaced with the Navier-Stokes solver GASP (General Aerodynamics Simulation Program). A test case with a proposed hypersonic test-vehicle configuration and associated freestream conditions was developed. The solutions of the GASP code with various surface boundary conditions were obtained and compared with those of the ASCC (ABRES Shape Change) code, and the effect of nonequilibrium gas as well as surface chemistry on surface heating and ablation rate were examined. 22 refs.

Chen, Y.K.; Henline, W.D. [National Aeronautics and Space Administration, Ames Research Center, Moffett Field, CA (United States)

1994-09-01T23:59:59.000Z

483

RADIOACTIVE HIGH LEVEL WASTE TANK PITTING PREDICTIONS: AN INVESTIGATION INTO CRITICAL SOLUTION CONCENTRATIONS  

SciTech Connect (OSTI)

A series of cyclic potentiodynamic polarization tests was performed on samples of ASTM A537 carbon steel in support of a probability-based approach to evaluate the effect of chloride and sulfate on corrosion the steel?s susceptibility to pitting corrosion. Testing solutions were chosen to systemically evaluate the influence of the secondary aggressive species, chloride, and sulfate, in the nitrate based, high-level wastes. The results suggest that evaluating the combined effect of all aggressive species, nitrate, chloride, and sulfate, provides a consistent response for determining corrosion susceptibility. The results of this work emphasize the importance for not only nitrate concentration limits, but also chloride and sulfate concentration limits.

Hoffman, E.

2012-11-08T23:59:59.000Z

484

NEUTRALIZATIONS OF HIGH ALUMINUM LOW URANIUM USED NUCLEAR FUEL SOLUTIONS CONTAINING GADOLINIUM AS A NEUTRON POISON  

SciTech Connect (OSTI)

H-Canyon will begin dissolving High Aluminum - Low Uranium (High Al/Low U) Used Nuclear Fuel (UNF) following approval by DOE which is anticipated in CY2011. High Al/Low U is an aluminum/enriched uranium UNF with small quantities of uranium relative to aluminum. The maximum enrichment level expected is 93% {sup 235}U. The High Al/Low U UNF will be dissolved in H-Canyon in a nitric acid/mercury/gadolinium solution. The resulting solution will be neutralized and transferred to Tank 39H in the Tank Farm. To confirm that the solution generated could be poisoned with Gd, neutralized, and discarded to the Savannah River Site (SRS) high level waste (HLW) system without undue nuclear safety concerns the caustic precipitation of simulant solutions was examined. Experiments were performed with three simulant solutions representative of the H-Canyon estimated concentrations in the final solutions after dissolution. The maximum U, Gd, and Al concentration were selected for testing from the range of solution compositions provided. Simulants were prepared in three different nitric acid concentrations, ranging from 0.5 to 1.5 M. The simulant solutions were neutralized to four different endpoints: (1) just before a solid phase was formed (pH 3.5-4), (2) the point where a solid phase was obtained, (3) 0.8 M free hydroxide, and (4) 1.2 M free hydroxide, using 50 wt % sodium hydroxide (NaOH). The settling behavior of the neutralized solutions was found to be slower compared to previous studies, with settling continuing over a one week period. Due to the high concentration of Al in these solutions, precipitation of solids was observed immediately upon addition of NaOH. Precipitation continued as additional NaOH was added, reaching a point where the mixture becomes almost completely solid due to the large amount of precipitate. As additional NaOH was added, some of the precipitate began to redissolve, and the solutions neutralized to the final two endpoints mixed easily and had expected densities of typical neutralized waste. Based on particle size and scanning electron microscopy analyses, the neutralized solids were found to be homogeneous and less than 20 microns in size. The majority of solids were less than 4 microns in size. Compared to previous studies, a larger percentage of the Gd was found to precipitate in the partially neutralized solutions (at pH 3.5-4). In addition the Gd:U mass ratio was found to be at least 1.0 in all of the solids obtained after partial or full neutralization. The hydrogen to U (H:U) molar ratios for two accident scenarios were also determined. The first was for transient neutralization and agitator failure. Experimentally this scenario was determined by measuring the H:U ratio of the settled solids. The minimum H:U molar ratio for solids from fully neutralized solutions was 388:1. The second accident scenario is for the solids drying out in an unagitiated pump box. Experimentally, this scenario was determined by measuring the H:U molar ratio in centrifuged solids. The minimum H:U atom ratios for centrifuged precipitated solids was 250:1. It was determined previously that a 30:1 H:Pu atom ratio was sufficient for a 1:1 Gd:Pu mass ratio. Assuming a 1:1 equivalence with {sup 239}Pu, the results of these experiments show Gd is a viable poison for neutralizing U/Gd solutions with the tested compositions.

Taylor-Pashow, K.

2011-06-08T23:59:59.000Z

485

Advanced Vehicle Testing and Evaluation  

SciTech Connect (OSTI)

The objective of the United States (U.S.) Department of Energy?s (DOEs) Advanced Vehicle Testing and Evaluation (AVTE) project was to provide test and evaluation services for advanced technology vehicles, to establish a performance baseline, to determine vehicle reliability, and to evaluate vehicle operating costs in fleet operations. Vehicles tested include light and medium-duty vehicles in conventional, hybrid, and all-electric configurations using conventional and alternative fuels, including hydrogen in internal combustion engines. Vehicles were tested on closed tracks and chassis dynamometers, as well as operated on public roads, in fleet operations, and over prescribed routes. All testing was controlled by procedures developed specifically to support such testing. Testing and evaluations were conducted in the following phases: ? Development of test procedures, which established testing procedures; ? Baseline performance testing, which established a performance baseline; ? Accelerated reliability testing, which determined vehicle reliability; ? Fleet testing, used to evaluate vehicle economics in fleet operation, and ? End of test performance evaluation. Test results are reported by two means and posted by Idaho National Laboratory (INL) to their website: quarterly progress reports, used to document work in progress; and final test reports. This final report documents work conducted for the entirety of the contract by the Clarity Group, Inc., doing business as ECOtality North America (ECOtality). The contract was performed from 1 October 2005 through 31 March 2013. There were 113 light-duty on-road (95), off-road (3) and low speed (15) vehicles tested.

Garetson, Thomas

2013-03-31T23:59:59.000Z

486

Fusion Test Facilities John Sheffield  

E-Print Network [OSTI]

Fusion Test Facilities John Sheffield ISSE - University of Tennessee FPA meeting Livermore December Stambaugh, and their colleagues #12;Destructive Testing · It is common practice to test engineered components to destruction prior to deployment of a system e.g., - Automobile crash tests - Airplane wing

487

Data Flow Testing Neelam Gupta  

E-Print Network [OSTI]

Data Flow Testing Neelam Gupta The University of Arizona, Tucson, Arizona and Rajiv Gupta The University of Arizona, Tucson, Arizona Software testing techniques are designed to execute a program on a set of test cases that provide suÃ?cient coverage under some speci#12;c well-de#12;ned test coverage criterion

Gupta, Rajiv

488

Developing the Right Test Documentation  

E-Print Network [OSTI]

and managing testing and test documentation. Over the past 17 years, we have criticized IEEE standard 829 (onDeveloping the Right Test Documentation Cem Kaner, J.D., Ph.D. Department of Computer Sciences Quality Conference #12;2Test Documentation Copyright © 2001 Cem Kaner and James Bach. All rights reserved

489

Hydroshear Simulation Lab Test 2  

SciTech Connect (OSTI)

This data file is for test 2. In this test a sample of granite with a pre cut (man made fracture) is confined, heated and differential stress is applied. max temperature in this this system development test is 95C. test details on the spreadsheets--note thta there are 2 spreadsheets

Bauer, Steve

2014-08-01T23:59:59.000Z

490

Hydroshear Simulation Lab Test 2  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

This data file is for test 2. In this test a sample of granite with a pre cut (man made fracture) is confined, heated and differential stress is applied. max temperature in this this system development test is 95C. test details on the spreadsheets--note thta there are 2 spreadsheets

Bauer, Steve

491

Inverse hydrochemical models of aqueous extracts tests  

SciTech Connect (OSTI)

Aqueous extract test is a laboratory technique commonly used to measure the amount of soluble salts of a soil sample after adding a known mass of distilled water. Measured aqueous extract data have to be re-interpreted in order to infer porewater chemical composition of the sample because porewater chemistry changes significantly due to dilution and chemical reactions which take place during extraction. Here we present an inverse hydrochemical model to estimate porewater chemical composition from measured water content, aqueous extract, and mineralogical data. The model accounts for acid-base, redox, aqueous complexation, mineral dissolution/precipitation, gas dissolution/ex-solution, cation exchange and surface complexation reactions, of which are assumed to take place at local equilibrium. It has been solved with INVERSE-CORE{sup 2D} and been tested with bentonite samples taken from FEBEX (Full-scale Engineered Barrier EXperiment) in situ test. The inverse model reproduces most of the measured aqueous data except bicarbonate and provides an effective, flexible and comprehensive method to estimate porewater chemical composition of clays. Main uncertainties are related to kinetic calcite dissolution and variations in CO2(g) pressure.

Zheng, L.; Samper, J.; Montenegro, L.

2008-10-10T23:59:59.000Z

492

LWRS ATR Irradiation Testing Readiness Status  

SciTech Connect (OSTI)

The Light Water Reactor Sustainability (LWRS) Program was established by the U.S. Department of Energy Office of Nuclear Energy (DOE-NE) to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the life of the current reactors. The LWRS Program is divided into four R&D Pathways: (1) Materials Aging and Degradation; (2) Advanced Light Water Reactor Nuclear Fuels; (3) Advanced Instrumentation, Information and Control Systems; and (4) Risk-Informed Safety Margin Characterization. This report describes an irradiation testing readiness analysis in preparation of LWRS experiments for irradiation testing at the Idaho National Laboratory (INL) Advanced Test Reactor (ATR) under Pathway (2). The focus of the Advanced LWR Nuclear Fuels Pathway is to improve the scientific knowledge basis for understanding and predicting fundamental performance of advanced nuclear fuel and cladding in nuclear power plants during both nominal and off-nominal conditions. This information will be applied in the design and development of high-performance, high burn-up fuels with improved safety, cladding integrity, and improved nuclear fuel cycle economics

Kristine Barrett

2012-09-01T23:59:59.000Z

493

Investigation of the sulfur and lithium to sulfur ratio threshold in stress corrosion cracking of sensitized alloy 600 in borated thiosulfate solution  

SciTech Connect (OSTI)

The stress corrosion cracking of sensitized Alloy 600 was investigated in aerated solutions of sodium thiosulfate generally containing 1.3% boric acid. The aim of the investigation, among others, was to determine the existence, if any, of a threshold level of sulfur, and lithium to sulfur ratio governing the SCC. Specimens were first solution annealed at 1135/sup 0/C for 45 minutes, water quenched, and then sensitized at 621/sup 0/C for 18 hours. Reverse U-bends were tested at room temperature, whereas slow strain rate and constant load tests were performed at 80/sup 0/C. All tests were performed in solutions open to the atmosphere. The results indicate that in the borated thiosulfate solution containing 7 ppM sulfur, 5 ppM lithium as lithium hydroxide is sufficient to inhibit SCC in U-bends. The occurrence of inhibition seems to correlate to the rapid increase of pH and conductivity of the solution as a result of the lithium hydroxide addition. In the slow strain rate tests in the borated solution containing 0.7 ppM lithium as lithium hydroxide, significant stress corrosion cracking is observed at a sulfur level of 30 ppb, i.e., a lithium to sulfur ratio of 23. In a parallel test in 30 ppb sulfur level but without any lithium hydroxide, the stress corrosion cracking is more severe than that in the lithiated environment, thus implying that lithium hydroxide plays some role in the stress corrosion cracking inhibition.

Bandy, R.; Kelly, K.

1984-07-01T23:59:59.000Z

494

Micro-tensile testing system  

DOE Patents [OSTI]

A micro-tensile testing system providing a stand-alone test platform for testing and reporting physical or engineering properties of test samples of materials having thicknesses of approximately between 0.002 inch and 0.030 inch, including, for example, LiGA engineered materials. The testing system is able to perform a variety of static, dynamic, and cyclic tests. The testing system includes a rigid frame and adjustable gripping supports to minimize measurement errors due to deflection or bending under load; serrated grips for securing the extremely small test sample; high-speed laser scan micrometers for obtaining accurate results; and test software for controlling the testing procedure and reporting results.

Wenski, Edward G. (Lenexa, KS)

2007-07-17T23:59:59.000Z

495

Micro-tensile testing system  

DOE Patents [OSTI]

A micro-tensile testing system providing a stand-alone test platform for testing and reporting physical or engineering properties of test samples of materials having thicknesses of approximately between 0.002 inch and 0.030 inch, including, for example, LiGA engineered materials. The testing system is able to perform a variety of static, dynamic, and cyclic tests. The testing system includes a rigid frame and adjustable gripping supports to minimize measurement errors due to deflection or bending under load; serrated grips for securing the extremely small test sample; high-speed laser scan micrometers for obtaining accurate results; and test software for controlling the testing procedure and reporting results.

Wenski, Edward G. (Lenexa, KS)

2007-08-21T23:59:59.000Z

496

Micro-tensile testing system  

DOE Patents [OSTI]

A micro-tensile testing system providing a stand-alone test platform for testing and reporting physical or engineering properties of test samples of materials having thicknesses of approximately between 0.002 inch and 0.030 inch, including, for example, LiGA engineered materials. The testing system is able to perform a variety of static, dynamic, and cyclic tests. The testing system includes a rigid frame and adjustable gripping supports to minimize measurement errors due to deflection or bending under load; serrated grips for securing the extremely small test sample; high-speed laser scan micrometers for obtaining accurate results; and test software for controlling the testing procedure and reporting results.

Wenski, Edward G.

2006-01-10T23:59:59.000Z

497

Analytic solutions for seismic travel time and ray path geometry through simple velocity models.  

SciTech Connect (OSTI)

The geometry of ray paths through realistic Earth models can be extremely complex due to the vertical and lateral heterogeneity of the velocity distribution within the models. Calculation of high fidelity ray paths and travel times through these models generally involves sophisticated algorithms that require significant assumptions and approximations. To test such algorithms it is desirable to have available analytic solutions for the geometry and travel time of rays through simpler velocity distributions against which the more complex algorithms can be compared. Also, in situations where computational performance requirements prohibit implementation of full 3D algorithms, it may be necessary to accept the accuracy limitations of analytic solutions in order to compute solutions that satisfy those requirements. Analytic solutions are described for the geometry and travel time of infinite frequency rays through radially symmetric 1D Earth models characterized by an inner sphere where the velocity distribution is given by the function V (r) = A-Br{sup 2}, optionally surrounded by some number of spherical shells of constant velocity. The mathematical basis of the calculations is described, sample calculations are presented, and results are compared to the Taup Toolkit of Crotwell et al. (1999). These solutions are useful for evaluating the fidelity of sophisticated 3D travel time calculators and in situations where performance requirements preclude the use of more computationally intensive calculators. It should be noted that most of the solutions presented are only quasi-analytic. Exact, closed form equations are derived but computation of solutions to specific problems generally require application of numerical integration or root finding techniques, which, while approximations, can be calculated to very high accuracy. Tolerances are set in the numerical algorithms such that computed travel time accuracies are better than 1 microsecond.

Ballard, Sanford

2007-12-01T23:59:59.000Z

498

Solvent extraction and recovery of the transuranic elements from waste solutions using the TRUEX process  

SciTech Connect (OSTI)

High-level liquid waste is produced during the processing of irradiated nuclear fuel by the PUREX process. In some cases the treatment of metallurgical scrap to recover the plutonium values also generates a nitric acid waste solution. Both waste solutions contain sufficient concentrations of transuranic elements (mostly /sup 241/Am) to require handling and disposal as a TRU waste. This paper describes a recently developed solvent extraction/recovery process called TRUEX (transuranium extraction) which is designed to reduce the TRU concentration in nitric waste solutions to <100 nCi/g of disposed form (1,2). (In the USA, non-TRU waste is defined as <100 nCi of TRU/g of disposed form.) The process utilizes PUREX process solvent (TBP in a normal paraffinic hydrocarbon or carbon tetrachloride) modified by a small concentration of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (abbrev. CMPO). The presence of CMPO enables the modified PUREX process solvent to extract trivalent actinides as well as tetra- and hexavalent actinides. A major feature of the TRUEX process is that is is applicable to waste solutions containing a wide range of nitric acid, salt, and fission product concentrations and at the same time is very compatible with existing liquid-liquid extraction technology as usually practiced in a fuel reprocessing plant. To date the process has been tested on two different types of synthetic waste solutions. The first solution is a typical high-level nitric acid waste and the second a typical waste solution generated in metallurgical scrap processing. Results are discussed. 4 refs., 1 fig., 4 tabs.

Horwitz, E.P.; Schulz, W.W.

1985-01-01T23:59:59.000Z

499

Long-term testing  

SciTech Connect (OSTI)

Land-based gas turbines are significantly different from automotive gas turbines in that they are designed to operate for 50,000 h or greater (compared to 5,000--10,000 h). The primary goal of this research is to determine the long-term survivability of ceramic materials for industrial gas turbine applications. Research activities in this program focus on the evaluation of the static tensile creep and stress rupture (SR) behavior of three commercially available structural ceramics which have been identified by the gas turbine manufacturers as leading candidates for use in industrial gas turbines. For each material investigated, a minimum of three temperatures and four stresses will be used to establish the stress and temperature sensitivities of the creep and SR behavior. Because existing data for many candidate structural ceramics are limited to testing times less than 2,000 h, this program will focus on extending these data to times on the order of 10,000 h, which represents the lower limit of operating time anticipated for ceramic blades and vanes in gas turbine engines. A secondary goal of the program will be to investigate the possibility of enhancing life prediction estimates by combining interrupted tensile SR tests and tensile dynamic fatigue tests in which tensile strength is measured as a function of stressing rate. The third goal of this program will be to investigate the effects of water vapor upon the SR behavior of the three structural ceramics chosen for the static tensile studies by measuring the flexural strength as a function of stressing rate at three temperatures.

Ferber, M.; Graves, G.A. Jr.

1994-12-31T23:59:59.000Z

500

CALiPER Testing Laboratories  

Broader source: Energy.gov [DOE]

CALiPER is not a testing laboratory or an accreditation organization. DOE established the CALiPER program to provide accurate and comparable data on LED products by arranging for reliable independent testing and data reporting of commercially available products. The CALiPER program established a process for qualifying testing laboratories to do this testing during the period when appropriate test standards such as LM-79 were under development and not yet covered by nationally recognized accreditation processes.