Powered by Deep Web Technologies
Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

STANDARD OPERATING PROCEDURE Location(s): ___________________________________________________  

E-Print Network (OSTI)

of as hazardous waste. 8. Decontamination: Specific instructions: For light contamination of small areas or items12.1 STANDARD OPERATING PROCEDURE for PHENOL Location(s): ___________________________________________________ Chemical(s): Phenol Specific Hazards: May be fatal if inhaled. Harmful if absorbed through skin. Harmful

Pawlowski, Wojtek

2

Chapter 7 - LNG Plant and Regasification Terminal Operations  

Science Journals Connector (OSTI)

Abstract A liquefied natural gas (LNG) production plant is designed to meet the production target with specifications that meet the contractual agreement while satisfying the emission and environmental regulations. The LNG liquefaction plant is a complex process, and for this reason, it is important to understand the design limitations and the process interaction among the different units for plant operation. The focus of this chapter is to discuss the process parameters and typical pitfalls that an operator may encounter in a day-to-day operation. Note that only the major process units that are critical to the LNG plant and regasification operation are addressed in the following sections. The generic units such as NGL fractionation units, condensate hydrotreating unit, refrigeration unit, and nitrogen rejection unit are left to the reader. This chapter also briefly addresses the general guidelines on the startup and shutdown of the LNG plant and the regasification terminal.

2014-01-01T23:59:59.000Z

3

Second Line of Defense, Port of Buenos Aires and Exolgan Container Terminal Operational Testing and Evaluation Plan, Buenos Aires, Argentina  

SciTech Connect

The Office of the Second Line of Defense (SLD) Megaports project team for Argentina will conduct operational testing and evaluation (OT&E) at Exolgan Container Terminal at the Port of Dock Sud from July 16-20, 2012; and at the Port of Buenos Aires from September 3-7, 2012. SLD is installing radiation detection equipment to screen export, import, and transshipment containers at these locations. The purpose of OT&E is to validate and baseline an operable system that meets the SLD mission and to ensure the system continues to perform as expected in an operational environment with Argentina Customs effectively adjudicating alarms.

Roberts, Bryan W.

2012-08-23T23:59:59.000Z

4

Second Line of Defense Megaports Initiative Operational Testing and Evaluation Plan - Kingston Container Terminal, Port of Kingston, Jamaica  

SciTech Connect

Operational Testing and Evaluation Plan - Kingston Container Terminal, Port of Kingston, Jamaica was written for the Second Line of Defense Megaports Initiative. The purpose of the Operational Testing and Evaluation (OT&E) phase of the project is to prepare for turnover of the Megaports system supplied by U.S. Department of Energy/National Nuclear Security Administration (DOE/NNSA) located at the Kingston Container Terminal (KCT) of the Port of Kingston, Jamaica to the Government of Jamaica (GOJ). Activities conducted during the OT&E phase must demonstrate that the Megaports system can be operated effectively in real time by Jamaica Customs and KCT personnel to the satisfaction of the DOE/NNSA. These activities will also determine if the Megaports system, as installed and accepted, is performing according to the Megaports Program objectives such that the system is capable of executing the mission of the Second Line of Defense Megaports Initiative. The OT&E phase of the project also provides an opportunity to consider potential improvements to the system and to take remedial action if performance deficiencies are identified during the course of evaluation. Changes to the system should be considered under an appropriate change-control process. DOE/NNSA will determine that OT&E is complete by examining whether the Megaports system is performing as intended and that the GOJ is fully capable of operating the system independently without continued onsite support from the U.S. team.

Deforest, Thomas J.; VanDyke, Damon S.

2012-03-01T23:59:59.000Z

5

Terminal Box Airflow Reset: An Effective Operation and Control Strategy for Comfort Improvement and Energy Conservation  

E-Print Network (OSTI)

terminal boxes, the maximum potential zone load during unoccupied hours must be considered. The airflow reset may be implemented using the terminal box controller only. However, central control systems may have to be used for most of the existing... control systems. One method is to develop two control schedules (occupied and unoccupied). Based on the time, the central control system automatically switch between two schedules. (downloads the un-occupied schedule to the terminal box controller...

Liu, M.; Abbas, M.; Zhu, Y.; Claridge, D. E.

2002-01-01T23:59:59.000Z

6

SIMULATION FOR THE EVALUATION OF OPTIMISED OPERATIONS POLICIES IN A CONTAINER TERMINAL  

E-Print Network (OSTI)

allocation policies, the load and unload scheduling policies. With the aid of the ISO 9001 documentation of the terminal is designed, implemented and validated. The simulation model is used to test the policies

Gambardella, Luca Maria

7

Exploring mathematical approximation for the time spans of transfer operations in parcel transshipment terminals  

Science Journals Connector (OSTI)

The parcel delivery industry (PDI) is a very labor intensive industry, from the drivers of the pickup and delivery vans, to the unloaders, sorters, and loaders in the transshipment terminals. The labor efficiency is a key performance measure in the PDI. ... Keywords: Cross-docking, Parcel delivery, Scheduling, Transportation

Douglas L. Mcwilliams; Maranda E. Mcbride

2013-01-01T23:59:59.000Z

8

Minimizing the completion time of the transfer operations in a central parcel consolidation terminal with unequal-batch-size inbound trailers  

Science Journals Connector (OSTI)

This paper addresses the scheduling of inbound trailers to unload docks at central parcel consolidation terminals in the parcel delivery industry, an industry that operates in a time-critical environment. The scheduling function can have a significant ... Keywords: Consolidation terminals, Distribution, Genetic algorithms, Parcel, Simulation-based scheduling

Douglas L. McWilliams; Paul M. Stanfield; Christopher D. Geiger

2008-05-01T23:59:59.000Z

9

Scale formation at various locations in a geothermal operation due to injection of imported waters  

SciTech Connect

The injection of waters that are not native to a geothermal formation generates various physical and chemical problems. The major chemical problem resulting from such injections is the formation of sulfate scales (particularly CaSO4, BaSO4 and SrSO4) at various locations starting from the injection well through the production well to the surface facilities of any geothermal operation. One of the ways to prevent this type of scale formation is by reducing the sulfate concentration of the injection waters. The effect of sulfate deionization on scale formation at various locations of the geothermal operations is studied. Some experimental results on the CaSO4 scale formation in porous media upon heating an injection water with and without addition of scale inhibitors are also given.

Vetter, O.J.; Kandarpa, V.

1982-06-22T23:59:59.000Z

10

Second Line of Defense Megaports Initiative Operational Testing and Evaluation Plan Colon Container Terminal (CCT) Panama  

SciTech Connect

Report on the Operational Testing and Evaluation to validate and baseline an operable system that meets the Second Line of Defense (SLD) mission requirements. An SLD system is defined as the detection technology and associated equipment, the system operators from the host country, the standard operating procedures (SOPs), and other elements such as training and maintenance which support long-term system sustainment. To this end, the activities conducted during the OT&E phase must demonstrate that the Megaports System can be operated effectively in real-time by Panama Direccion General de Aduanas (DGA Panama Customs) personnel to the standards of the U.S. Department of Energy/National Nuclear Security Administration (DOE/NNSA).

Newhouse, Robert N.

2010-01-01T23:59:59.000Z

11

Project Project Funding Operational & Maintenance Costs Univ. Project Title GSF Brief Description of Project Location Amount Source  

E-Print Network (OSTI)

Project Project Funding Operational & Maintenance Costs Univ. Project Title GSF Brief Description of Project Location Amount Source UF Minor Projects for UF 50,000 Minor projects for facilities located and education. Typical projects consist of Gainesville/ Typical projects other funding greenhouses, general

Slatton, Clint

12

Thermodynamic-Analysis-Based Design and Operation for Boil-Off Gas Flare Minimization at LNG Receiving Terminals  

Science Journals Connector (OSTI)

The LNG (liquefied natural gas) receiving terminal is an important component of the entire LNG value chain. ... Corpus Christi, TX, U.S. ...

Chaowei Liu; Jian Zhang; Qiang Xu; John L. Gossage

2010-07-14T23:59:59.000Z

13

The effect of weaving maneuvers on operation of a free right-turn lane at ramp terminals  

E-Print Network (OSTI)

-turn vehicles on a departure leg. If the ramp terminal is closely followed by the next downstream intersection, weaving maneuvers will occur since some vehicles make a right turn at the ramp terminal and make a left turn at the downstream intersection...

Park, Minchul

2006-04-12T23:59:59.000Z

14

Applications of Automatic Vehicle Location systems towards improving service reliability and operations planning in London  

E-Print Network (OSTI)

Technological advances in the transit industry, such as the introduction of Automatic Vehicle Location (AVL) systems, have provided agencies with robust data collection and measurement systems and enabled the development ...

Ehrlich, Joseph Emanuel

2010-01-01T23:59:59.000Z

15

Termination unit  

DOE Patents (OSTI)

This invention relates to a termination unit comprising an end-section of a cable. The end section of the cable defines a central longitudinal axis and comprising end-parts of N electrical phases, an end-part of a neutral conductor and a surrounding thermally insulation envelope adapted to comprising a cooling fluid. The end-parts of the N electrical phases and the end-part of the neutral conductor each comprising at least one electrical conductor and being arranged in the cable concentrically around a core former with a phase 1 located relatively innermost, and phase N relatively outermost in the cable, phase N being surrounded by the neutral conductor, electrical insulation being arrange between neighboring electrical phases and between phase N and the neutral conductor, and wherein the end-parts of the neutral conductor and the electrical phases each comprise a contacting surface electrically connected to at least one branch current lead to provide an electrical connection: The contacting surfaces each having a longitudinal extension, and being located sequentially along the longitudinal extension of the end-section of the cable. The branch current leads being individually insulated from said thermally insulation envelope by individual electrical insulators.

Traeholt, Chresten [Frederiksberg, DK; Willen, Dag [Klagshamn, SE; Roden, Mark [Newnan, GA; Tolbert, Jerry C [Carrollton, GA; Lindsay, David [Carrollton, GA; Fisher, Paul W [Heiskell, TN; Nielsen, Carsten Thidemann [Jaegerspris, DK

2014-01-07T23:59:59.000Z

16

Leak Testing and Implications of Operations to Locate Leak Horizons at West Hackberry Well 108  

SciTech Connect

The Strategic Petroleum Reserve site at West Hackberry, Louisiana has historically experienced casing leaks. Numerous West Hackberry oil storage caverns have wells exhibiting communication between the interior 10 3/4 x 20-inch (oil) annulus and the ''outer cemented'' 20 x 26-inch annulus. Well 108 in Cavern 108 exhibits this behavior. It is thought that one, if not the primary, cause of this communication is casing thread leaks at the 20-inch casing joints combined with microannuli along the cement casing interfaces and other cracks/flaws in the cemented 20 x 26-inch annulus. An operation consisting of a series of nitrogen leak tests, similar to cavern integrity tests, was performed on Cavern 108 in an effort to determine the leak horizons and to see if these leak horizons coincided with those of casing joints. Certain leaky, threaded casing joints were identified between 400 and 1500 feet. A new leak detection procedure was developed as a result of this test, and this methodology for identifying and interpreting such casing joint leaks is presented in this report. Analysis of the test data showed that individual joint leaks could be successfully identified, but not without some degree of ambiguity. This ambiguity is attributed to changes in the fluid content of the leak path (nitrogen forcing out oil) and possibly to very plausible changes in characteristics of the flow path during the test. These changes dominated the test response and made the identification of individual leak horizons difficult. One consequence of concern from the testing was a progressive increase in the leak rate measured during testing due to nitrogen cleaning small amounts of oil out of the leak paths and very likely due to the changes of the leak path during the flow test. Therefore, careful consideration must be given before attempting similar tests. Although such leaks have caused no known environmental or economic problems to date, the leaks may be significant because of the potential for future problems. To mitigate future problems, some repair scenarios are discussed including injection of sealants.

SATTLER, ALLAN R.; EHGARTNER, BRIAN L.; PIECHOCKI, ALAN

2002-06-01T23:59:59.000Z

17

Terminal structure  

DOE Patents (OSTI)

A terminal structure (2) for a superconducting cable (1) is described. It consists of a conductor (2a) and an insulator (2b) that surrounds the conductor (2a), wherein the superconducting cable (1) has a core with a superconducting conductor (5) and a layer of insulation that surrounds the conductor (5), and wherein the core is arranged in such a way that it can move longitudinally in a cryostat. The conductor (2a) of the terminal structure (2) is electrically connected with the superconducting conductor (5) or with a normal conductor (6) that is connected with the superconducting conductor (5) by means of a tubular part (7) made of an electrically conductive material, wherein the superconducting conductor (5) or the normal conductor (6) can slide in the part (7) in the direction of the superconductor.

Schmidt, Frank (Langenhagen, DE); Allais, Arnaud (Hannover, DE); Mirebeau, Pierre (Villebon sur Yvette, FR); Ganhungu, Francois (Vieux-Reng, FR); Lallouet, Nicolas (Saint Martin Boulogne, FR)

2009-10-20T23:59:59.000Z

18

The location of two-hand trip devices on full revolution mechanical power presses with regard to operator safety  

E-Print Network (OSTI)

, , Point of operation. Flywheel dl ive and single geared trans- m1 8'-' lo l 12 Accepted safe openings between the bottom edg of. a guard and feed table at various distances from the point of operation. . . . . . . 21 Timing arrangemen't used by Lobl...' cal presses I s I, h(l conversion of rotary motion of a flywheel to rcl i J)F oca. ? ting motion of the pre. , s ram by means of an eccentric. The most common form of eccentricity used on mech;)ni. cal 2 presses is the crankshaf*. Other forms...

Masters, Randall Wayne

2012-06-07T23:59:59.000Z

19

Categorical Exclusion Determinations: Idaho Operations Office | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Idaho Operations Office Idaho Operations Office Categorical Exclusion Determinations: Idaho Operations Office Categorical Exclusion Determinations issued by Idaho Operations Office. DOCUMENTS AVAILABLE FOR DOWNLOAD July 11, 2013 CX-010699: Categorical Exclusion Determination North Boulevard Annex Lease Termination CX(s) Applied: B1.24 Date: 07/11/2013 Location(s): Idaho Offices(s): Idaho Operations Office July 11, 2013 CX-010698: Categorical Exclusion Determination Modeling and Validation of Sodium Plugging for Heat Exchangers in Sodium-cooled Fast Reactor Systems CX(s) Applied: B3.6 Date: 07/11/2013 Location(s): Illinois Offices(s): Idaho Operations Office June 25, 2013 CX-010701: Categorical Exclusion Determination Materials and Fuels Complex Diversion Dam CX(s) Applied: B2.5 Date: 06/25/2013

20

Improving Building Comfort and Energy Savings of the McKenzie Airport Terminal by Maintaining and Improving Pneumatic Control Systems  

E-Print Network (OSTI)

McKenzie Airport Terminal is located at Easterwood Airport, which is owned and operated by Texas A&M University. It was built in 1988. Most all HVAC equipment, which includes boiler, chiller, pumps, AHUs and exhaust fans, due to lack of maintenance...

Liu, C.; Bruner, H. L.; Deng, S.; Brundidge, T.; Turner, W. D.; Claridge, D. E.

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Stillwell Avenue Terminal Train Shed  

New York, NY Coney Island's Stillwell Avenue Terminal is the largest above-ground station in New York City's subway system. After years of deferred maintenance, the 90-year-old station was redesigned by New York City Transit's in-house design staff. The train shed's new arched-truss structure covers four platforms and eight tracks. The train shed was designed to meet demanding maintenance, durability, and operations requirements.

22

International land rig locator  

SciTech Connect

Mechanical specifications, ratings, locations, and status are listed for each of the 5,000 contract rotary drilling rigs operated by the more than 700 independent drilling contractors throughout the Free World.

Not Available

1984-03-01T23:59:59.000Z

23

International land rig locator  

SciTech Connect

Mechanical specifications, ratings, locations, and status are listed for each of the 5,000 contract rotary drilling rigs operated by more than 700 independent drilling contractors throughout the Free World.

Not Available

1983-09-01T23:59:59.000Z

24

Tiltrotor Acoustic Flight Test: Terminal Area Operations  

Science Journals Connector (OSTI)

This paper provides a comprehensive description of an acoustic flight test of the XV-15 Tiltrotor Aircraft with Advanced Technology Blades (ATB) conducted in August and September 1991 at Crows Landing, California. The purpose of this cooperative research ...

Maria O. L. Santa; Wellman J. B.; Conner D. A.; Rutledge C. K.

1992-06-01T23:59:59.000Z

25

Controls modelling and verification for the Pacific Intertie HVDC 4 terminal scheme  

SciTech Connect

A detailed digital model for the actual control system of the Pacific Intertie HVDC scheme is presented. The scheme is operated as multi-terminal bipole HVDC with four terminals in parallel. Each pole comprises two separately located converter station with independent converter controls at each end of the transmission line. The control model includes bipole, pole, station and converter control systems. Special control techniques for providing safe and stable operation of the parallel converters are described. The techniques also result in fast recovery of the HVDC transmission scheme following severe ac and dc system disturbances. Verification of the completeness and accuracy of the model are made using field tests made on the actual HVDC scheme.

Hammad, A.; Minghetti, R.; Hasler, J.; Eicher, P. (ABB Power Systems, Baden (Switzerland)); Bunch, R.; Goldsworthy, D. (Bonneville Power Administration, Portland, OR (United States))

1993-01-01T23:59:59.000Z

26

Termination and Recovery  

Directives, Delegations, and Requirements

This volume defines event Termination and determination of when it is appropriate to cease emergency response activities and of associated notifications. Canceled by DOE G 151.1-4.

1997-08-21T23:59:59.000Z

27

SECURITY TERMINATION STATEMENT | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SECURITY TERMINATION STATEMENT SECURITY TERMINATION STATEMENT Form provides an individual's statement in connection with the termination of access authorization (security...

28

Calibration and operational data for a compact photodiode detector useful for monitoring the location of moving sources of positron emitting radioisotopes  

SciTech Connect

D-Pace has developed a compact cost-effective gamma detector system based on technology licensed from TRIUMF. These photodiode detectors are convenient for detecting the presence of positron emitting radioisotopes, particularly for the case of transport of radioisotopes from a PET cyclotron to hotlab, or from one location to another in an automated radiochemistry processing unit. This paper describes recent calibration experiments undertaken at the Turku PET Centre for stationary and moving sources of F18 and C11 in standard setups. The practical diagnostic utility of using several of these devices to track the transport of radioisotopes from the cyclotron to hotlab is illustrated. For example, such a detector system provides: a semi-quantitative indication of total activity, speed of transport, location of any activity lost en route and effectiveness of follow-up system flushes, a means of identifying bolus break-up, feedback useful for deciding when to change out tubing.

Marsland, M. G.; Dehnel, M. P.; Theroux, J.; Christensen, T.; Hollinger, C. [D-Pace, Inc. P.O. Box 201, Nelson, B.C., V1L 5P9 (Canada); Johansson, S.; Rajander, J.; Solin, O. [Turku PET Center, Abo Akademi University, Porthansgatan 3, Turku FI-20500 (Finland); Stewart, T. M. [D-Pace, Inc. P.O. Box 201, Nelson, B.C., V1L 5P9 (Canada)

2013-04-19T23:59:59.000Z

29

Reversible micromachining locator  

DOE Patents (OSTI)

This invention provides a device which includes a locator, a kinematic mount positioned on a conventional tooling machine, a part carrier disposed on the locator and a retainer ring. The locator has disposed therein a plurality of steel balls, placed in an equidistant position circumferentially around the locator. The kinematic mount includes a plurality of magnets which are in registry with the steel balls on the locator. In operation, a blank part to be machined is placed between a surface of a locator and the retainer ring (fitting within the part carrier). When the locator (with a blank part to be machined) is coupled to the kinematic mount, the part is thus exposed for the desired machining process. Because the locator is removably attachable to the kinematic mount, it can easily be removed from the mount, reversed, and reinserted onto the mount for additional machining. Further, the locator can likewise be removed from the mount and placed onto another tooling machine having a properly aligned kinematic mount. Because of the unique design and use of magnetic forces of the present invention, positioning errors of less than 0.25 micrometer for each machining process can be achieved. 7 figs.

Salzer, L.J.; Foreman, L.R.

1999-08-31T23:59:59.000Z

30

Optimization Control Strategies for HVAC Terminal Boxes  

E-Print Network (OSTI)

The HVAC terminal boxes are one of the major building HVAC components. They directly impact the building room comfort conditions and the energy costs. How to operate the box in a highly energy efficient way and maintain the room comfort level...

Zhu, Y.; Batten, T.; Noboa, H.; Claridge, D. E.; Turner, W. D.; Liu, M.; Zhou, J.; Cameron, C.; Keeble, D.; Hirchak, R.

2000-01-01T23:59:59.000Z

31

Shipboard regasification terminal  

SciTech Connect

Mobil Technology Company and Mobil Shipping and Transportation Company have jointly developed a new combination of existing proven equipment to regasify LNG. Advantages of this Shipboard Regasification Terminal (SRT) include accelerated initial gas delivery schedule, low capital cost, delivery of smaller quantities of LNG at a competitive price and shorter term of LNG purchase and improved financing options. These advantages benefit both the supplier of LNG and the purchaser. SRT can be used as an interim supply to developing markets allowing the demand to grow while developing downstream infrastructure. This concept does not involve offshore transfer of cryogenic fluids while delivering near-ambient temperature pipeline quality gas at typical pipeline pressures. During times when gas is not required, the SRT ship can easily be returned to the trade of transporting and delivering LNG to conventional land based terminals. This paper will discuss the merits of Shipboard Regasification Terminals in general, cover the development of this concept and review the factors guiding the use of SRT vs. an onshore terminal.

Campbell, G.; Zednik, J.

1999-07-01T23:59:59.000Z

32

Generalized Terminal Modeling of Electromagnetic Interference  

SciTech Connect

Terminal models have been used for various applications. In this paper, a three-terminal model is proposed for electromagnetic-interference (EMI) characterization. The model starts with a power electronic system at a particular operating condition and creates a unique linearized equivalent circuit. Impedances and current/voltage sources define the noise throughout the entire EMI frequency spectrum. All parameters needed to create the model are clearly defined to ensure convergence and maximize accuracy. In addition, the accuracy of the model is confirmed up to 100 MHz for a dc-dc boost converter using both simulation and experimental validation.

Baisden, Andrew Carson [IEEE Industrial Applications Society; Boroyevich, Dushan [Virginia Polytechnic Institute and State University (Virginia Tech); Wang, Fei [ORNL

2010-01-01T23:59:59.000Z

33

Entrance Maze Locations  

NLE Websites -- All DOE Office Websites (Extended Search)

Entrance Maze Locations Entrance Maze Locations for the Storage Ring Tunnel Martin Knott LS-83 2/17/87 The Purpose of this note is to document the locations and decision rationale of the entrance mazes for the APS storage ring. There are a total of seven entrance mazes, four on the infield side and three on the operating floor side of the ring. Three of the infield mazes are associated with infield buildings, one in the Extraction Building and one each in the two RF Buildings. These three were located to provide convenient passage between the technical buildings and the storage ring components associated with those buildings. The Extraction Building maze allows passage between the positron beam transfer area and the storage ring two sectors upstream of the injection

34

Terminal area flight path generation using parallel constraint propagation  

E-Print Network (OSTI)

A Flight Path Generator is defined as the module of an automated Air Traffic Control system which plans aircraft trajectories in the terminal area with respect to operational constraints. The flight path plans have to be ...

Sadoune, Michel

1989-01-01T23:59:59.000Z

35

Section 5 -Termination of Occupancy A. Involuntary Termination of Occupancy  

E-Print Network (OSTI)

Section 5 - Termination of Occupancy A. Involuntary Termination of Occupancy 1. Housing and Dining number of credits at UAA as stipulated in Section 2 - Eligibility, and for non-payment of Housing charges. 2. The University may terminate this agreement without cause with ten days written notice. 3

Pantaleone, Jim

36

Performance testing of the Sandy Pond HVDC converter terminal  

SciTech Connect

Results of several performance tests for the 1,800 MW Sandy Pond HVDC converter terminal are presented and discussed. The work progressed during 1990 and 1991 and included tests for power line carrier interference, audible sound, ac and dc line faults and dc harmonic performance. The testing was conducted as part of the commissioning program for the first stage of the Quebec-New England Phase 2 multi-terminal system. In this stage, the Radisson (Quebec) and Sandy Pond (New England) terminals are operational.

Donahue, J.A.; Fisher, D.A.; Railing, B.D.; Tatro, P.J. (New England Power Service Co., Westborough, MA (United States))

1993-01-01T23:59:59.000Z

37

A two-stage supply chain DEA model for measuring container-terminal efficiency  

Science Journals Connector (OSTI)

Despite the growing amount of research into container-port operations and efficiency, much of the literature on the subject treats container ports and terminals as black box systems without examining the structure of their transformation and production processes. Research on the network and multi-stage structure of container-terminal operating systems is scarce and its applications in the context of port performance and benchmarking are even scarcer. In this paper, we argue that the container terminal production would be best modelled as a network of interrelated sub-processes and operating sites and develop a supply chain DEA model aimed at capturing the transformational process within the container-terminal system and across its sub-systems. We start by modelling container terminal operations as a container-flow process and analyse their site-specific and combined efficiency before formalising a two-stage supply chain DEA model to measure the efficiencies of both individual and network container terminal operations. Although, due to the unavailability of detailed operational data, this study is limited to container export flows only, the results provide further insight on the network structure of container-terminal operating systems and confirm the existence of disproportionate performances and efficiency levels between container-terminal operating sites and sub-processes.

Khalid Bichou

2011-01-01T23:59:59.000Z

38

MOBILE-TERMINATED DATA User's Guide  

E-Print Network (OSTI)

MOBILE-TERMINATED DATA User's Guide Iridium Satellite LLC Rev. 2; February 1, 2002 #12;MOBILE................................................................................................................................3 1.1 IRIDIUM MOBILE TERMINATED DATA CONNECTIVITY ..........................................................................................................................7 4 Mobile Terminated Call Scenarios

Ashley, Michael C. B.

39

Vacuum State/Refiner/Location  

U.S. Energy Information Administration (EIA) Indexed Site

Vacuum Vacuum State/Refiner/Location Barrels per Atmospheric Crude Oil Distillation Capacity Barrels per Operating Idle Operating Idle Downstream Charge Capacity Thermal Cracking Delayed Fluid Coking Visbreaking Other/Gas Calendar Day Stream Day Distillation Coking Oil Table 3. Capacity of Operable Petroleum Refineries by State as of January 1, 2013 (Barrels per Stream Day, Except Where Noted) ......................................................... Alabama 120,100 0 130,000 0 48,000 32,000 0 0 0 Goodway Refining LLC 4,100 0 5,000 0 0 0 0 0 0 ....................................................................................................................................................................................................

40

Modeling of Electronically Commutated Motor Controlled Fan-powered Terminal Units  

E-Print Network (OSTI)

Feet Per Minute ECM Electronically Commutated Motor FPTU Fan Powered Terminal Unit Pdown Downstream Static Pressure PF Power Factor Pup Upstream Static Pressure SCR Silicon Controlled Rectifier THD Total Harmonic Distortion VAV Variable Air... parallel unit pressurizes the FPTU causing some of the primary air to leak out of the unit. Another difference between them is that series terminal units allow the primary air system to operate at a lower static pressure because the terminal unit fan...

Edmondson, Jacob Lee

2011-02-22T23:59:59.000Z

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Terminals and Ports Jan C. Willems  

E-Print Network (OSTI)

)+···+Vp(t)Ip(t) dt. These expressions for power and energy are not valid unless the set of terminals forms a port. We conclude that terminals are for interconnection, and ports are for energy transfer. We formulate terminals, while energy transfer happens via ports. We consider systems that interact through terminals

42

Library Locations Locations other than Main Library  

E-Print Network (OSTI)

Library Locations Locations other than Main Library Example: Feminist Studies HQ1410 .U54 2009 University of California, Santa Barbara Library www.library.ucsb.edu Updated 3-2014 A - B.......................................6 Central M - N..................................................Arts Library (Music Building) P

43

Robust door assignment in less-than-truckload terminals  

Science Journals Connector (OSTI)

The assignment of incoming trailers to strip doors is one of the critical decisions that affect the performance of cross docking operations in less-than-truckload terminals. This paper introduces a mixed integer quadratic model with the objective of ... Keywords: Cross docking, Door assignment, Less-than-truckload, Transportation, Uncertainty

Korhan Acar; Ali Yalcin; Daniel Yankov

2012-12-01T23:59:59.000Z

44

Three-terminal semiconductor laser for wave mixing  

E-Print Network (OSTI)

-terminal design has been recently pro- posed to obtain a dual-wavelength operation of an InxGa12xN light emitting diode ~LED! @6#. In that work, a strongly doped p11/n11 tunnel junction layer was intro- duced between two MQW segments that were emitting at two...

Belyanin, Alexey; Kocharovsky, V.; Kocharovsky, V.; Scully, Marlan O.

2002-01-01T23:59:59.000Z

45

Vehicle Dispatching Problem at the Container Terminal with Tandem Lift Quay Cranes  

E-Print Network (OSTI)

, the tandem lift operations bring new challenges to the vehicle dispatching at terminals and this has become a big issue in the application of tandem lift QCs. The vehicle dispatching at terminals is to enhance the QCs productivities by coordinating the QCs...

Xing, Yao

2013-07-09T23:59:59.000Z

46

Termination-Insensitive Computational Indistinguishability  

E-Print Network (OSTI)

indistinguishability: termination-insensitive computational indistinguishability (tic-indistinguishability). Tic in a formula will provide information on its definition. Try it and click here: M tic. (On slower computers. Contents 1 Introduction 2 1.1 Defining tic-indistinguishability 3 1.2 Machine model independence 5 1

47

Universal null DTE (data terminal equipment)  

DOE Patents (OSTI)

A communication device in the form of data terminal equipment permits two data communication equipments, each having its own master clock and operating at substantially the same nominal clock rate, to communicate with each other in a multi-segment circuit configuration of a general communication network even when phase or frequency errors exist between the two clocks. Data transmitted between communication equipments of two segments of the communication network is buffered. A variable buffer fill circuit is provided to fill the buffer to a selectable extent prior to initiation of data output clocking. Selection switches are provided to select the degree of buffer preload. A dynamic buffer fill circuit may be incorporated for automatically selecting the buffer fill level as a function of the difference in clock frequencies of the two equipments. Controllable alarm circuitry is provided for selectively generating an underflow or an overflow alarm to one or both of the communicating equipments. 5 figs.

George, M.; Pierson, L.G.; Wilkins, M.E.

1987-11-09T23:59:59.000Z

48

DOE Terminated Federal Advisory Committees  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

TERMINATED FEDERAL ADVISORY COMMITTEES Date Committee Name/Web Site Terminated Federal Energy Management Advisory Committee 06/08/07 Web Site: (Environmental Management Site-Specific Advisory Board) Fernald 09/30/06 Web Site: (Environmental Management Site-Specific Advisory Board) Rocky Flats 09/30/06 Web Site: Secretary of Energy Advisory Board 05/20/06 Web Site: http://www.seab.energy.gov/ Electricity Advisory Board 02/10/06 Web Site: http://www.eab.doe.gov/ American Statistical Association Advisory Committee on Energy Statistics 03/24/05 Web Site: Workers' Compensation Assistance Advisory Committee 06/29/04 Web Site: National Nuclear Security Administration Advisory Committee 06/25/03 Web Site: Commission on Fire Safety and Preparedness 01/09/03

49

Clothes Dryer Automatic Termination Evaluation  

SciTech Connect

Volume 2: Improved Sensor and Control Designs Many residential clothes dryers on the market today provide automatic cycles that are intended to stop when the clothes are dry, as determined by the final remaining moisture content (RMC). However, testing of automatic termination cycles has shown that many dryers are susceptible to over-drying of loads, leading to excess energy consumption. In particular, tests performed using the DOE Test Procedure in Appendix D2 of 10 CFR 430 subpart B have shown that as much as 62% of the energy used in a cycle may be from over-drying. Volume 1 of this report shows an average of 20% excess energy from over-drying when running automatic cycles with various load compositions and dryer settings. Consequently, improving automatic termination sensors and algorithms has the potential for substantial energy savings in the U.S.

TeGrotenhuis, Ward E.

2014-10-01T23:59:59.000Z

50

Terminal Operations for Tube Trailer and Liquid Tanker Filling...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

and Liquid Tanker Filling: Status, Challenges and R&D Needs 1 Linde covers the entire hydrogen value chain LH 2 storage SupplyStorage CompressionTransfer Dispenser Onsite SMR...

51

Petroleum Refining Operations: Key Issues, Advances, and Opportunities  

Science Journals Connector (OSTI)

A typical petroleum industry supply chain is composed of an exploration phase at the wellhead, crude procurement and storage logistics, transportation to the refineries, refinery operations, and distribution and delivery of its products (Figure 1). ... This network is used to transport crude from wellhead to refinery for processing, to transport intermediates between multisite refining facilities, and to transport finished products from product storage tanks to distribution centers and finally to the customers. ... In common-carrier pipelines, however, several refineries located at different sites use the same trunk line for shipping refined petroleum products to downstream output terminals. ...

Nikisha K. Shah; Zukui Li; Marianthi G. Ierapetritou

2010-12-10T23:59:59.000Z

52

ARM - Instrument Location Table  

NLE Websites -- All DOE Office Websites (Extended Search)

govInstrumentsLocation Table govInstrumentsLocation Table Instruments Location Table Contacts Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Instrument Locations Site abbreviations explained in the key. Instrument Name Abbreviation NSA SGP TWP AMF C1 C2 EF BF CF EF IF C1 C2 C3 EF IF Aerosol Chemical Speciation Monitor ACSM Atmospheric Emitted Radiance Interferometer AERI Aethalometer AETH Ameriflux Measurement Component AMC Aerosol Observing System AOS Meteorological Measurements associated with the Aerosol Observing System AOSMET Broadband Radiometer Station BRS

53

The Terminal-Oriented Ship Stowage Planning Problem  

Science Journals Connector (OSTI)

Abstract The Ship Stowage Planning Problem is the problem of determining the optimal position of containers to be stowed in a containership. In this paper we address the problem considering the objectives of the terminal management that are mainly related to the yard and transport operations. We propose a Binary Integer Program and a two-step heuristic algorithm. An extensive computational experience shows the efficiency and effectiveness of our approach. A classification scheme for stowage planning problems is also provided.

Maria Flavia Monaco; Marcello Sammarra; Gregorio Sorrentino

2014-01-01T23:59:59.000Z

54

Monitored Geologic Repository Operations Monitoring and Control System Description Document  

SciTech Connect

The Monitored Geologic Repository Operations Monitoring and Control System provides supervisory control, monitoring, and selected remote control of primary and secondary repository operations. Primary repository operations consist of both surface and subsurface activities relating to high-level waste receipt, preparation, and emplacement. Secondary repository operations consist of support operations for waste handling and treatment, utilities, subsurface construction, and other selected ancillary activities. Remote control of the subsurface emplacement operations, as well as, repository performance confirmation operations are the direct responsibility of the system. In addition, the system monitors parameters such as radiological data, air quality data, fire detection status, meteorological conditions, unauthorized access, and abnormal operating conditions, to ensure a safe workplace for personnel. Parameters are displayed in a real-time manner to human operators regarding surface and subsurface conditions. The system performs supervisory monitoring and control for both important to safety and non-safety systems. The system provides repository operational information, alarm capability, and human operator response messages during emergency response situations. The system also includes logic control to place equipment, systems, and utilities in a safe operational mode or complete shutdown during emergency response situations. The system initiates alarms and provides operational data to enable appropriate actions at the local level in support of emergency response, radiological protection response, evacuation, and underground rescue. The system provides data communications, data processing, managerial reports, data storage, and data analysis. This system's primary surface and subsurface operator consoles, for both supervisory and remote control activities, will be located in a Central Control Center (CCC) inside one of the surface facility buildings. The system consists of instrument and control equipment and components necessary to provide human operators with sufficient information to monitor and control the operation of the repository in an efficient and safe manner. The system consists of operator consoles and workstations, multiple video display terminals, communications and interfacing equipment, and instrument and control software with customized configuration to meet the needs of the Monitored Geologic Repository (MGR). Process and logic controllers and the associated input/output units of each system interfaced with this system will be configured into Remote Terminal Units (RTU) and located close to the systems to be monitored and controlled. The RTUs are configured to remain operational should communication with CCC operations be lost. The system provides closed circuit television to selectively view systems, operations, and equipment areas and to aid in the operation of mechanical systems. Control and monitoring of site utility systems will be located in the CCC. Site utilities include heating, ventilation, and air conditioning equipment; plant compressed air; plant water; firewater; electrical systems; and inert gases, such as nitrogen, if required. This system interfaces with surface and subsurface systems that either generate output data or require remote control input. The system interfaces with the Site Communications System for bulk storage of operational data, on-site and off-site communication, and a plant-wide public announcement system. The system interfaces with the Safeguards and Security System to provide operational status and emergency alarm indications. The system interfaces with the Site Operation System to provide site wide acquisition of data for analysis and reports, historical information for trends, utility information for plant operation, and to receive operating plans and procedures.

E.F. Loros

2000-06-29T23:59:59.000Z

55

Novel techniques for fault location, voltage profile calculation and visualization of transients  

E-Print Network (OSTI)

This dissertation addresses three different problems in power systems. The first problem is related to the fault location in complex topologies such as three terminal circuits with series compensation and mutually coupled line sections...

Evrenosoglu, Cansin Yaman

2009-05-15T23:59:59.000Z

56

SSA Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Area Operations (SSA-Ops) Area Operations (SSA-Ops) "BOREAS Ops" was located at the Snodrifters Lodge, in Candle Lake, Saskatchewan. Radiosonde balloon launch at Ops The NASA Helicopter lands at Ops A meeting at the Snodrifter's Lodge Release of a radiosonde at the SSA operations center in Candle Lake. Back to the BOREAS Photo Page Index Other Sites: NSA Photos ||NSA-BP Photos | NSA-Fen Photos | NSA-OA Photos | NSA-OBS Photos | NSA-OJP Photos | NSA-UBS Photos | NSA-YJP Photos | NSA-Ops Photos SSA Photos || SSA-Airport Photos | SSA-Fen Photos | SSA-Mix Photos | SSA-OA Photos | SSA-OBS Photos | SSA-OJP Photos | SSA-YA Photos | SSA-YJP Photos | SSA-Ops Photos | ORNL DAAC Home || ORNL Home || NASA || Privacy, Security, Notices || Data Citation || Rate Us || Help | User Services - Tel: +1 (865) 241-3952 or E-mail: uso@daac.ornl.gov

57

EIS-0493: Corpus Christi LNG Terminal and Pipeline Project, Nueces and San  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3: Corpus Christi LNG Terminal and Pipeline Project, Nueces 3: Corpus Christi LNG Terminal and Pipeline Project, Nueces and San Patricio Counties, Texas EIS-0493: Corpus Christi LNG Terminal and Pipeline Project, Nueces and San Patricio Counties, Texas SUMMARY The Federal Energy Regulatory Commission (FERC) is preparing, with DOE as a cooperating agency, an EIS to analyze the potential environmental impacts of a proposal to construct and operate a liquefied natural gas export and import terminal on the north shore of Corpus Christi Bay in Nueces and San Patricio Counties, Texas; a marine berth connecting the terminal to the adjacent La Quinta Channel; and an approximately 23-mile-long natural gas transmission pipeline and associated facilities. In June 2012, FERC issued a notice of intent to prepare an EA; in October 2012, FERC announced that

58

Our Locations | National Nuclear Security Administration  

NLE Websites -- All DOE Office Websites (Extended Search)

Locations | National Nuclear Security Administration Locations | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Our Locations Home > About Us > Our Locations Our Locations The NNSA's nuclear security enterprise spans eight sites, including three national laboratories, with more than six decades of cutting-edge nuclear security experience. That history and technical expertise enables NNSA to

59

Our Locations | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Locations | National Nuclear Security Administration Locations | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Our Locations Home > About Us > Our Locations Our Locations The NNSA's nuclear security enterprise spans eight sites, including three national laboratories, with more than six decades of cutting-edge nuclear security experience. That history and technical expertise enables NNSA to

60

Helicopter magnetic survey conducted to locate wells  

SciTech Connect

A helicopter magnetic survey was conducted in August 2007 over 15.6 sq mi at the Naval Petroleum Reserve No. 3s (NPR-3) Teapot Dome Field near Casper, Wyoming. The surveys purpose was to accurately locate wells drilled there during more than 90 years of continuous oilfield operation. The survey was conducted at low altitude and with closely spaced flight lines to improve the detection of wells with weak magnetic response and to increase the resolution of closely spaced wells. The survey was in preparation for a planned CO2 flood for EOR, which requires a complete well inventory with accurate locations for all existing wells. The magnetic survey was intended to locate wells missing from the well database and to provide accurate locations for all wells. The ability of the helicopter magnetic survey to accurately locate wells was accomplished by comparing airborne well picks with well locations from an intense ground search of a small test area.

Veloski, G.A.; Hammack, R.W.; Stamp, V. (Rocky Mountain Oilfield Testing Center); Hall, R. (Rocky Mountain Oilfield Testing Center); Colina, K. (Rocky Mountain Oilfield Testing Center)

2008-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Operating System Resource Management  

E-Print Network (OSTI)

Operating System Resource Management Date: Monday, September 27, 2010 Time: 2:00 ­ 3:00 pm Location allocation and de-allocation by an operating system of processor cores, memory pages, and various types constrained. This talk will propose a scheme for addressing the operating system resource management problem

62

Reading Room Locations  

NLE Websites -- All DOE Office Websites (Extended Search)

FOIA Offices and Reading Rooms FOIA Offices and Reading Rooms FOIA Office Locations Our FOIA Officers are located at various sites throughout the DOE complex, each with responsibility for records located at or under the jurisdiction of the site. We recommend that you send your request directly to that specific site. This will shorten the processing time. However, if you do not know which location has responsive records, you may either call the Headquarters FOIA office at (202) 586-5955 to determine the appropriate office, or mail the request to the Headquarters FOIA office. Other records are publicly available in the facilities listed below: Headquarters U.S. Department of Energy FOIA/Privacy Act Group 1000 Independence Avenue, SW Washington, D.C. 20585 Phone: 202-586-5955 Fax: 202-586-0575

63

Location linked information  

E-Print Network (OSTI)

This work builds an infrastructure called Location Linked Information that offers a means to associate digital information with public, physical places. This connection creates a hybrid virtual/physical space, called glean ...

Mankins, Matthew William David, 1975-

2003-01-01T23:59:59.000Z

64

Lower Bounding Procedures for the Single Allocation Hub Location ...  

E-Print Network (OSTI)

[9] O'Kelly, M. E., A quadratic integer program for the location of interacting hub facilities, European Journal of Operational Research 32 (1987), pp. 393404.

2014-11-30T23:59:59.000Z

65

Wind Turbine Manufacturers in the U. S.: Locations and Local...  

Wind Powering America (EERE)

Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Wind Turbine Manufacturers in the U.S.: Locations and Local Impacts WINDPOWER 2010 Conference...

66

STANDARD OPERATING PROCEDURE ACIDS CONTAINING PHOSPHOROUS  

E-Print Network (OSTI)

12.1 STANDARD OPERATING PROCEDURE for ACIDS CONTAINING PHOSPHOROUS Location(s): ___________________________________________________ Chemical(s): Hypophosphorous acid, methylphosphonic acid, phosphonic acid, phosphoric acid, phosphorous

Pawlowski, Wojtek

67

Categorical Exclusion Determinations: Other Location | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Other Location Other Location Categorical Exclusion Determinations: Other Location Location Categorical Exclusion Determinations issued for actions in other locations. DOCUMENTS AVAILABLE FOR DOWNLOAD September 28, 2011 CX-006938: Categorical Exclusion Determination Developing Lithium-Ion Cells for Electric Vehicle Batteries CX(s) Applied: B3.6 Date: 09/28/2011 Location(s): Daejeon, South Korea, Other Location Office(s): Energy Efficiency and Renewable Energy, Savannah River Operations Office September 28, 2011 CX-006922: Categorical Exclusion Determination Amerigon Waste Heat Recovery Program for Passenger Vehicles CX(s) Applied: A9, B3.6 Date: 09/28/2011 Location(s): Germany, California, Indiana, Michigan Office(s): Energy Efficiency and Renewable Energy, Savannah River Operations Office

68

Power line carrier interference from HVDC converter terminals  

SciTech Connect

Power line carrier (PLC) equipment typically operates in the frequency range from 25 kHz to 300 kHz. Interference studies for HVDC converters usually concentrate on interference from noise sources within this frequency range. However, operating experience at the Sandy Pond converter terminal has indicated that PLC equipment is also susceptible to interference from sources of power system harmonics below the PLC frequency range. Extensive field testing and analytical studies have shown that each PLC circuit has a resonant frequency below the operating frequency. If excited at this resonant frequency, high voltages may exist within the PLC circuit. The resulting saturation of PLC components leads to local generation of radio frequency (RF) noise that interferes with proper operation of PLC circuits. Sources of power system harmonics in the 3-10 kHz range, such as line commutated dc converters, are potential sources of this type of interference.

Tatro, P.J.; Adamson, K.A. (New England Power Service Co., Westborough, MA (United States)); Eitzmann, M.A.; Smead, M. (GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.)

1993-07-01T23:59:59.000Z

69

Fast Neighbor Discovery with Lightweight Termination Detection in Heterogeneous Cognitive Radio Networks  

E-Print Network (OSTI)

the congestion within the frequency spectrum. A cognitive radio transceiver can operate over a wide range of the spectrum that the CR node can operate on may be allocated to licensed users who are known as primary usersFast Neighbor Discovery with Lightweight Termination Detection in Heterogeneous Cognitive Radio

Mittal, Neeraj

70

EIS-0493: Corpus Christi LNG Terminal and Pipeline Project, Nueces and San Patricio Counties, Texas  

Energy.gov (U.S. Department of Energy (DOE))

The Federal Energy Regulatory Commission (FERC) is preparing, with DOE as a cooperating agency, an EIS to analyze the potential environmental impacts of a proposal to construct and operate a liquefied natural gas export and import terminal on the north shore of Corpus Christi Bay in Nueces and San Patricio Counties, Texas; a marine berth connecting the terminal to the adjacent La Quinta Channel; and an approximately 23-mile-long natural gas transmission pipeline and associated facilities.

71

a r r i o r BUILDING# NAME LOCATION BUILDING# NAME LOCATION OTHER BUILDINGS LOCATION SORORITIES LOCATION  

E-Print Network (OSTI)

Admissions Parking Palmer Lake B l a c k W a r r i o r R i v e r BUILDING# NAME LOCATION BUILDING# NAME LOCATION OTHER BUILDINGS LOCATION SORORITIES LOCATION 7046 70127012 1155 10331033 1150 1039 1038

Carver, Jeffrey C.

72

location | OpenEI  

Open Energy Info (EERE)

location location Dataset Summary Description No description given. Source Oak Ridge National Laboratory Date Released November 30th, 2009 (5 years ago) Date Updated Unknown Keywords biodiesel ethanol location production capacity transportation Data application/zip icon Biorefineries.zip (zip, 7 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Time Period License License Other or unspecified, see optional comment below Comment Rate this dataset Usefulness of the metadata Average vote Your vote Usefulness of the dataset Average vote Your vote Ease of access Average vote Your vote Overall rating Average vote Your vote Comments Login or register to post comments If you rate this dataset, your published comment will include your rating.

73

Pine Tree Growth Locations  

NLE Websites -- All DOE Office Websites (Extended Search)

Pine Tree Growth Locations Pine Tree Growth Locations Name: Amielee Location: N/A Country: N/A Date: N/A Question: Why do pine trees not grow south of the equator? Replies: Dear Amielee, The natural distribution of the pines is the northern hemisphere: http://phylogeny.arizona.edu/tree/eukaryotes/green_plants/embryophytes/conif ers/pinaceae/pinus/pinus.html However, pines have become introduced into the southern hemisphere through cultivation: http://www.woodweb.com/~treetalk/Radiata_Pine/wowhome.html Sincerely, Anthony R. Brach, Ph.D. Hi Amielee Some pine trees do live south of the equator but we (I live in Australia) do not have the huge forests of native conifers that you have in the northern hemisphere. Even in the northern hemisphere conifers are only found in two forest types: 1. Tiaga

74

UNIT NAME -C-340 PCB Spill Site REGULATORY STATUS CERCLA LOCATION  

NLE Websites -- All DOE Office Websites (Extended Search)

NAME -C-340 PCB Spill Site REGULATORY STATUS CERCLA LOCATION C-340 Transformer area (Map locat1on 74 )- APPROXIMATE DIMENSIDNS Unnown - FUNCTION Scill site- OPERATIONAL STATUS NA...

75

University Location Project Description  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Location Project Description Location Project Description Boise State University Boise, Idaho Boise State University has undertaken a study of the structural setting and geothermal potential at Neal Hot Springs that will integrate geology, geochemistry, and geophysics to analyze the site on the western Snake River plain. Boise State will determine if Neal Hot Springs sustains the necessary rock dilation and conduit pathways for hydrothermal fluid flow and successful geothermal development. The result will be new data acquisition, including a deep geophysical survey and fault surface data. Colorado School of Mines Golden, Colorado Colorado School of Mines will conduct an investigation near Homedale, Idaho, an area that straddles volcanic rock and unconsolidated sediments.

76

Lower Columbia River Terminal Fisheries Research Project : Final Environmental Assessment.  

SciTech Connect

This notice announces BPA`S`s decision to fund the Oregon Department of Fish and Wildlife (ODFW), the Washington Department of Fish and Wildlife (WDFW), and the Clatsop Economic Development Committee for the Lower Columbia River Terminal Fisheries Research Project (Project). The Project will continue the testing of various species/stocks, rearing regimes, and harvest options for terminal fisheries, as a means to increase lower river sport and commercial harvest of hatchery fish, while providing both greater protection of weaker wild stocks and increasing the return of upriver salmon runs to potential Zone 6 Treaty fisheries. The Project involves relocating hatchery smolts to new, additional pen locations in three bays/sloughs in the lower Columbia River along both the Oregon and Washington sides. The sites are Blind Slough and Tongue Point in Clatsop County, Oregon, and Grays Bay/Deep River, Wahkiakum County, Washington. The smolts will be acclimated for various lengths of time in the net pens and released from these sites. The Project will expand upon an existing terminal fisheries project in Youngs Bay, Oregon. The Project may be expanded to other sites in the future, depending on the results of this initial expansion. BPA`S has determined the project is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, the preparation of an environmental impact statement is not required, and BPA`S is issuing this FONSI.

United States. Bonneville Power Administration.

1995-04-01T23:59:59.000Z

77

Computer Lab Information Location  

E-Print Network (OSTI)

M340 Computer Lab Information · Location: The computer labs accessible to you are Weber 205 it is recommended that you save your files on a floppy when you are finished. · There is another directory, g:\\m340 to the saved files you have to add the directory to the Matlab path. To do this type addpath g:\\m340

Dangelmayr, Gerhard

78

Property:EIA/861/NercLocation | Open Energy Information  

Open Energy Info (EERE)

NercLocation NercLocation Jump to: navigation, search This is a property of type String. Description: Nerc Location NERC Location: The North American Electric Reliability Corporation (NERC) region where the utility has its primary business operations (service territory), electrical generation, transmission, and distribution equipment, and its administrative headquarters. Some utilities have business operations and service areas in more than one NERC region. Power marketers, because they generally have only office equipment, can have business operations in any NERC region. FRCC = Florida Reliability Coordinating Council; MRO = Midwest Reliability Organization; NPCC = Northeast Power Coordinating Council; RFC = Reliability First Corporation (formerly MAAC, MAIN and ECAR); SERC = SERC Reliability Corporation; SPP =

79

traveladvisory Terminal Roadway Closure 6-23 to 7-01-2010  

E-Print Network (OSTI)

to Central Parking. · Parking Passport Gold will be located on Level 2. PUBLIC TRANSPORTATION MBTA BLUE LINE SERVICE · Massport's courtesy shuttle bus service to the MBTA Blue Line Airport Station will pick up & drop off on the upper levels of Terminals A & B. Shuttle Bus #22 MBTA SILVER LINE SERVICE · Silver Line

Paulsson, Johan

80

Clean Cities: Coalition Locations  

NLE Websites -- All DOE Office Websites (Extended Search)

Locations Locations Clean Cities coalitions are primarily located in major metropolitan areas throughout the United States. Select the dots on the map for information about individual coalitions. See also the list of coalitions by designation date. United States map showing Clean Cities Coalition locations. Philadelphia State of Delaware Capitol Clean Cities of Connecticut Connecticut Southwestern Area New Haven Norwich Red River Valley (Grand Forks, Winnipeg, Manitoba, Canada) Silicon Valley (San Jose) East Bay (Oakland) San Francisco Sacramento Granite State State of Vermont Northeast Ohio Clean Transportation (Cleveland) Detroit Clean Communities of Western New York (Buffalo) Central New York (Syracuse) Capital District (Albany) Empire Clean Cities State of Maryland Washington DC Metropolitan South Shore Western Riverside County Southern California Association of Governments (SCAG) Atlanta Alabama Denver Philadelphia State of Delaware Las Vegas Washington DC Metropolitan Massachusetts Clean Cities Lone Star Clean Fuels Alliance (Austin) Southeast Florida Chicago Land of Enchantment Wisconsin-Southeast Area Southern Colorado Clean Cities Coalition Long Beach Antelope Valley Utah Clean Cities State of Maryland Kentucky Clean Cities Partnership Coalition Rogue Valley State of West Virginia San Joaquin Valley San Francisco Columbia-Willamette St. Louis Central New York (Syracuse) Dallas/Ft. Worth Honolulu Central Arkansas Pittsburgh Southern California Association of Governments (SCAG) Los Angeles Coachella Valley Region Northern Colorado Central Oklahoma (Oklahoma City) Virginia Clean Cities Coalition San Diego Regional Clean Cities Coalition Greater Long Island Maine Clean Communities Tulsa Valley of the Sun (Phoenix) Western Riverside County New Jersey Genesee Region (Rochester) Western Washington Clean Cities (Seattle) Ocean State Connecticut Connecticut2 Kansas City Regional Coalition Greater Indiana Clean Cities Coalition Capital District (Albany) Tucson Central Florida Clean Cities Coalition Alamo Area (San Antonio) Greater Baton Rouge Clean Cities Coalition Triangle (Raleigh, Durham, Chapel Hill) Twin Cities Clean Fuels Ohio Yellowstone-Teton Clean Energy Coalition Greater Lansing Palmetto State Houston-Galveston Middle Tennessee East Tennessee Clean Fuels Coalition Centralina Clean Fuels Coalition State of Iowa Treasure Valley Central Coast Southeast Louisiana Clean Fuels Partnership Land of Sky Coalition

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Clean Cities: Coalition Locations  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Locations Locations Clean Cities coalitions are primarily located in major metropolitan areas throughout the United States. Select the dots on the map for information about individual coalitions. See also the list of coalitions by designation date. United States map showing Clean Cities Coalition locations. Philadelphia State of Delaware Capitol Clean Cities of Connecticut Connecticut Southwestern Area New Haven Norwich Red River Valley (Grand Forks, Winnipeg, Manitoba, Canada) Silicon Valley (San Jose) East Bay (Oakland) San Francisco Sacramento Granite State State of Vermont Northeast Ohio Clean Transportation (Cleveland) Detroit Clean Communities of Western New York (Buffalo) Central New York (Syracuse) Capital District (Albany) Empire Clean Cities State of Maryland Washington DC Metropolitan South Shore Western Riverside County Southern California Association of Governments (SCAG) Atlanta Alabama Denver Philadelphia State of Delaware Las Vegas Washington DC Metropolitan Massachusetts Clean Cities Lone Star Clean Fuels Alliance (Austin) Southeast Florida Chicago Land of Enchantment Wisconsin-Southeast Area Southern Colorado Clean Cities Coalition Long Beach Antelope Valley Utah Clean Cities State of Maryland Kentucky Clean Cities Partnership Coalition Rogue Valley State of West Virginia San Joaquin Valley San Francisco Columbia-Willamette St. Louis Central New York (Syracuse) Dallas/Ft. Worth Honolulu Central Arkansas Pittsburgh Southern California Association of Governments (SCAG) Los Angeles Coachella Valley Region Northern Colorado Central Oklahoma (Oklahoma City) Virginia Clean Cities Coalition San Diego Regional Clean Cities Coalition Greater Long Island Maine Clean Communities Tulsa Valley of the Sun (Phoenix) Western Riverside County New Jersey Genesee Region (Rochester) Western Washington Clean Cities (Seattle) Ocean State Connecticut Connecticut2 Kansas City Regional Coalition Greater Indiana Clean Cities Coalition Capital District (Albany) Tucson Central Florida Clean Cities Coalition Alamo Area (San Antonio) Greater Baton Rouge Clean Cities Coalition Triangle (Raleigh, Durham, Chapel Hill) Twin Cities Clean Fuels Ohio Yellowstone-Teton Clean Energy Coalition Greater Lansing Palmetto State Houston-Galveston Middle Tennessee East Tennessee Clean Fuels Coalition Centralina Clean Fuels Coalition State of Iowa Treasure Valley Central Coast Southeast Louisiana Clean Fuels Partnership Land of Sky Coalition

82

Russian Locations | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Locations | National Nuclear Security Administration Locations | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog The National Nuclear Security Administration Russian Locations Home > About Us > Our Programs > Defense Programs > Future Science & Technology Programs > Office of Advanced Simulation and Computing and Institutional R&D Programs > Russia Tri-Lab S&T Collaborations > Travel

83

Termination of a Major Normal Fault | Open Energy Information  

Open Energy Info (EERE)

Termination of a Major Normal Fault: Major normal fault terminations or tip-lines sometimes split into multiple closely-spaced faults that result in increased...

84

Chapter 5 Terminal Lake Level Variability and Man's Attempts to Cope it with them  

Science Journals Connector (OSTI)

Publisher Summary Terminal lakes are usually located in the arid, lightly populated regions. The lack of understanding about the nature of terminal lakes is not only unfortunate but also potentially dangerous and costly to structures, agricultural undertakings, and utilization of such lakes as chemical sources, transportation links, or recreation areas. Because closed lakes have no outlet, their level, surface area, and volume are dependent on the drainage and evaporation rate of their closed environment. The size of terminal lakes is, thus, dependent on the weather or more accurately its long-term effect, climate. Because the essence of weather and climate is change, it follows that the essence of terminal lakes is also change. Man interferes with terminal lakes and their mechanisms, thereby upsetting the balance regulated by nature. Two of the best known examples of problem-plagued terminal lakes and man's efforts to utilize, control, and regulate them are found today in the Soviet Union's Caspian Sea and the Great Salt Lake in the United States.

D.C. Greer

1980-01-01T23:59:59.000Z

85

Test Cell Location  

NLE Websites -- All DOE Office Websites (Extended Search)

Mazda 3 i-Stop Mazda 3 i-Stop Test Cell Location APRF- 4WD Vehicle Setup Information Downloadable Dynamometer Database (D 3 )- Test Summary Sheet Vehicle Architecture Conventional- Start Stop Vehicle Dynamometer Input Document Date 11/20/2012 Advanced Powertrain Research Facility Test weight [lb] 3250 Vehicle Dynamometer Input Document Date 11/20/2012 Revision Number 1 Advanced Powertrain Research Facility Test weight [lb] Target A [lb] 3250 31.2 Target B [lb/mph] Target C [lb/mph^2] 0.462 0.014 Test Fuel Information - Vehicle equipped with with i-Stop package - Manual Transmission - All tests completed in ECO mode - EPA shift schedule modified based on vehicle shift light activity Revision Number 1 Notes: Fuel type EPA Tier II EEE Gasoline Test Fuel Information - Vehicle equipped with with i-Stop package

86

Locations Everyone: Lights, Camera, Action!  

Science Journals Connector (OSTI)

Locations Everyone: Lights, Camera, Action! ... Harvard Institute of Proteomics Harvard Medical School ...

Robert F. Murphy; Joshua LaBaer

2008-12-05T23:59:59.000Z

87

Optimal fault location  

E-Print Network (OSTI)

for the pre-selected time out to pass and initiate reclosing again. If after selected number of attempts of reclosing, fault is still present, breaker lockout is taking place. There will be no more attempts to reclose automatically the breaker again....2: Trip and reclose sequences on a single breaker In the case of breaker lockout the assumption taken by the operators is that fault is permanent. Special order is issued to the maintenance for the breaker to be closed back in 4 again once...

Knezev, Maja

2009-05-15T23:59:59.000Z

88

Optimal fault location  

E-Print Network (OSTI)

for the pre-selected time out to pass and initiate reclosing again. If after selected number of attempts of reclosing, fault is still present, breaker lockout is taking place. There will be no more attempts to reclose automatically the breaker again....2: Trip and reclose sequences on a single breaker In the case of breaker lockout the assumption taken by the operators is that fault is permanent. Special order is issued to the maintenance for the breaker to be closed back in 4 again once...

Knezev, Maja

2008-10-10T23:59:59.000Z

89

PCs and Computer Terminals in Commercial Buildings  

U.S. Energy Information Administration (EIA) Indexed Site

Special Topics and Data Reports > PC's and Computer Terminals Special Topics and Data Reports > PC's and Computer Terminals Picture of a personal computer Personal Computers and Computer Terminals in Commercial Buildings PCs and Computer Terminals in 1995 Changes Between 1992 and 1995 How the Number of PCs and Computer Terminals Were Estimated References and Additional Links Over the past 10 to 15 years, the use of personal computers (PCs) has risen dramatically. The energy consumed by PCs and other types of office equipment has become a significant component of electricity consumption in commercial buildings -- 13 percent (98 billion kWh) of all electricity consumed in 1995. That amount was nearly as much as the amount used to air condition these buildings. The Energy Information Administration's 1999 Annual Energy Outlook[1] forecasts that, for the next two decades, electricity consumption for office equipment (3.2 percent annually) will grow over twice as fast as electricity use as a whole (1.4 percent annually).

90

Feedthrough terminal for high-power cell  

DOE Patents (OSTI)

A feedthrough terminal for a high power electrochemical storage cell providing low resistance coupling to the conductive elements therein while isolating the terminal electrode from the highly corrosive environment within the cell is disclosed. A large diameter, cylindrical copper electrode is enclosed in a stainless steel tube with a BN powder feedthrough seal maintained around the stainless steel tube by means of facing insulative bushings and an outer sleeve. One end of the copper conductor is silver-brazed directly to a flat, butterfly bus bar within the cell, with the adjacent end of the surrounding outer feedthrough sleeve welded to the bus bar. A threaded seal is fixedly positioned on a distal portion of the stainless steel tube immediately adjacent the distal insulative bushing so as to compress the feedthrough seal in tight fitting relation around the stainless steel tube in providing a rugged, leak-proof electrical feedthrough terminal for the power cell.

Kaun, T.D.

1982-05-28T23:59:59.000Z

91

Operations Information  

NLE Websites -- All DOE Office Websites (Extended Search)

Standards BPA Operations Information (OPI) Transmission Services operates and plans for regional and national system needs. Transmission Services coordinates system operation and...

92

Test Cell Location  

NLE Websites -- All DOE Office Websites (Extended Search)

Chrysler 300 Chrysler 300 Test Cell Location 2WD Vehicle Setup Information Downloadable Dynamometer Database (D 3 )- Test Summary Sheet Vehicle Architecture Conventional Vehicle Dynamometer Input Document Date 8/7/2013 Advanced Powertrain Research Facility Test weight [lb] Target A [lb] 4250 38.61 Target B [lb/mph] Target C [lb/mph^2] 0.8894 0.01105 3.6L VVT Port-injected V-6 8 speed Transmission Revision Number 3 Notes: Test Fuel Information 3.6L VVT Port-injected V-6 8 speed Transmission Fuel type Tier II EEE HF437 3.6L VVT Port-injected V-6 8 speed Transmission Fuel density [g/ml] Fuel Net HV [BTU/lbm] 0.743 18490 T e s t I D [ # ] C y c l e C o l d s t a r t ( C S t ) H o t s t a r t [ H S t ] D a t e T e s t C e l l T e m p [ C ] T e s t C e l l R H [ % ] T e s t C e l l B a r o [ i n / H g ] V e h i c l e c o o l i n g f a n s p e e d : S p e e d M a t c h [ S M ] o r c o n s t a n t s p e e d [ C S ] S

93

Sandia National Laboratories: Locations: Livermore, California: Visiting  

NLE Websites -- All DOE Office Websites (Extended Search)

California California Livermore, California administration building Our location and hours of operation Sandia/California is located at 7011 East Avenue in Livermore, Calif., a suburban community about 45 miles east of San Francisco. Positioned at the eastern edge of the San Francisco Bay Area, Sandia is within easy commuting distance of many affordable housing communities in San Joaquin County and the Central Valley. The official hours of operation at Sandia/California are from 7:30 a.m. to 4 p.m. PST, Monday through Friday. General inquiries can be made by calling (925) 294-3000. See our contacts page for additional information. Getting here All three major airports in the San Francisco Bay Area provide access to Sandia/California. Oakland International Airport is the closest airport to

94

Guide to the Library Locations  

E-Print Network (OSTI)

Guide to the Libraries #12;Library Locations W.E.B. DU BOIS LIBRARY www.library.umass.edu 154 Hicks Way (413) 545-0150, (413) 545-2622 The Du Bois Library is the primary location for resources machine, and a fax machine. Quiet study space is located on Floors 2 and 3 and throughout the upper floors

Massachusetts at Amherst, University of

95

Spring loaded locator pin assembly  

DOE Patents (OSTI)

This invention deals with spring loaded locator pins. Locator pins are sometimes referred to as captured pins. This is a mechanism which locks two items together with the pin that is spring loaded so that it drops into a locator hole on the work piece.

Groll, Todd A. (Idaho Falls, ID); White, James P. (Pocatelo, ID)

1998-01-01T23:59:59.000Z

96

Spring loaded locator pin assembly  

DOE Patents (OSTI)

This invention deals with spring loaded locator pins. Locator pins are sometimes referred to as captured pins. This is a mechanism which locks two items together with the pin that is spring loaded so that it drops into a locator hole on the work piece. 5 figs.

Groll, T.A.; White, J.P.

1998-03-03T23:59:59.000Z

97

Off-line ion source terminal for ISAC at TRIUMF  

SciTech Connect

The off-line ion source (OLIS) terminal consists of a microwave cusp ion source, either a surface ion source or a hybrid surface-arc discharge ion source and an electrostatic switch that allows selecting any one of the sources without mechanical intervention. These sources provide variety of beams to ISAC experiments, for commissioning the accelerators, for setting up the radioactive experiments, and for tuning the beam lines. The microwave ion source has been operational since 1995 and provides singly and doubly charged beams from various stable isotopes for many ISAC experiments at high and low energy areas. Originally its prime goal was to provide beams from gaseous elements, but later two ovens and a sputtering system were added in order to provide beams from liquids and from solids. The surface ion source installed in 2002 can provide low energy spread beams from alkali and semialkali elements. It also has three separate ovens and an ionizer. Therefore, it can provide three different temperature regions simultaneously to provide different beams to ISAC. It is mainly used for laser spectroscopy experiments and other experiments, which require a finite beam quality. A hybrid surface-arc discharge ion source was also developed and installed in order to meet specific demands from experiments. This source terminal is now automated for start up and for mass selection. It is capable of providing stable beams for months without maintenance and it is also capable of providing negative ion beams if required. To date, over 40 different isotopes including many rear isotopes were delivered to various experiments from the OLIS source terminal. Performances of the ion sources and some of the results are discussed.

Jayamanna, K.; Ames, F.; Cojocaru, G.; Baartman, R.; Bricault, P.; Dube, R.; Laxdal, R.; Marchetto, M.; MacDonald, M.; Schmor, P.; Wight, G.; Yuan, D. [TRIUMF, 4004 Wesbrook Mall, Vancouver BC V6T 2A3 (Canada)

2008-02-15T23:59:59.000Z

98

Cost reduction ideas for LNG terminals  

SciTech Connect

LNG projects are highly capital intensive and this has long been regarded as being inevitable. However, recent developments are forcing the LNG industry to aggressively seek cost reductions. For example, the gas-to-liquids (GTL) process is increasingly seen as a potential rival technology and is often being touted as an economically superior alternative fuel source. Another strong driving force behind needed cost reductions is the low crude oil price which seems to have settled in the $10--13/bb. range. LNG is well positioned as the fuel of choice for environmentally friendly new power projects. As a result of the projected demand for power especially in the Pacific Rim countries several LNG terminal projects are under consideration. Such projects will require a new generation of LNG terminal designs emphasizing low cost, small scale and safe and fully integrated designs from LNG supply to power generation. The integration of the LNG terminal with the combined cycle gas turbine (CCGT) power plant offers substantial cost savings opportunities for both plants. Various cost reduction strategies and their impact on the terminal design are discussed including cost reduction due to integration.

Habibullah, A.; Weldin, F.

1999-07-01T23:59:59.000Z

99

eRA Training Team1 Terminations  

E-Print Network (OSTI)

eRA Training Team1 xTrain Terminations Electronic Research Administration Sponsored by: The National Institutes of Health, Office of Extramural Research March 2012 #12;eRA Training Team2 xTrain General Information xTrain Overview The following section provides general information on the xTrain

Baker, Chris I.

100

eRA Training Team1 Terminations  

E-Print Network (OSTI)

eRA Training Team1 xTrain Terminations Electronic Research Administration Sponsored by: The National Institutions of Health, Office of Extramural Research April 2010 #12;eRA Training Team2 xTrain General Information xTrain Overview The following section provides general information on the xTrain

Baker, Chris I.

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Mobile Alternative Fueling Station Locator  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Alternative Fueling Station Locator Alternative Fueling Station Locator Fuel Type Biodiesel (B20 and above) Compressed Natural Gas Electric Ethanol (E85) Hydrogen Liquefied Natural Gas (LNG) Liquefied Petroleum Gas (Propane) Location Enter a city, postal code, or address Include private stations Not all stations are open to the public. Choose this option to also search private fueling stations. Search Caution: The AFDC recommends that users verify that stations are open, available to the public, and have the fuel prior to making a trip to that location. Some stations in our database have addresses that could not be located by the Station Locator application. This may result in the station appearing in the center of the zip code area instead of the actual location. If you're having difficulty, please contact the technical response team at

102

LOCATION: Johnson County Sheriff's Office  

NLE Websites -- All DOE Office Websites (Extended Search)

LOCATION: Johnson County Sheriff's Office Criminalistics Laboratory 11890 Sunset Drive Olathe, Kansas 66061 DATE: JULY 15TH - JULY 18TH, 2013 TUITION: MAFS MEMBERS: 550 Non-MAFS...

103

Declaration of Termination of Domestic Partnership Form  

NLE Websites -- All DOE Office Websites (Extended Search)

DPT (01-2012) DPT (01-2012) SANDIA PROPRIETARY INFORMATION PERSONALLY IDENTIFIABLE INFORMATION (PII) (WHEN COMPLETE) Declaration of Termination of Domestic Partnership Form To be completed by the employee and submitted to the Sandia Benefits Customer Service Center at the address above. Please keep a copy for your records. Sworn Affidavit We, __________________________________________ and _____________________________________________ Employee Domestic Partner __________________________________________ _____________________________________________ Employee Social Security Number Domestic Partner Social Security Number __________________________________________ _____________________________________________ Employee Date of Birth Domestic Partner Date of Birth

104

Termination of Safeguards for Accountable Nuclear Materials at the Idaho National Laboratory  

SciTech Connect

Termination of safeguards ends requirements of Nuclear Material Control and Accountability (MC&A) and thereby removes the safeguards basis for applying physical protection requirements for theft and diversion of nuclear material, providing termination requirements are met as described. Department of Energy (DOE) M 470.4 6 (Nuclear Material Control and Accountability [8/26/05]) stipulates: 1. Section A, Chapter I (1)( q) (1): Safeguards can be terminated on nuclear materials provided the following conditions are met: (a) 'If the material is special nuclear material (SNM) or protected as SNM, it must be attractiveness level E and have a measured value.' (b) 'The material has been determined by DOE line management to be of no programmatic value to DOE.' (c) 'The material is transferred to the control of a waste management organization where the material is accounted for and protected in accordance with waste management regulations. The material must not be collocated with other accountable nuclear materials.' Requirements for safeguards termination depend on the safeguards attractiveness levels of the material. For attractiveness level E, approval has been granted from the DOE Idaho Operations Office (DOE ID) to Battelle Energy Alliance, LLC (BEA) Safeguards and Security (S&S). In some cases, it may be necessary to dispose of nuclear materials of attractiveness level D or higher. Termination of safeguards for such materials must be approved by the Departmental Element (this is the DOE Headquarters Office of Nuclear Energy) after consultation with the Office of Security.

Michael Holzemer; Alan Carvo

2012-04-01T23:59:59.000Z

105

Chapter 9 -Forklift Operations Forklift Operations Safety Rules  

E-Print Network (OSTI)

, or hazardous locations. 19. Operators should not put their fingers, arms, or legs between the uprights that horn, lights, brakes, tires, gas supply, hydraulic lines, etc. are in safe working condition. Employees

106

Simulation of proton radiography terminal at IMP  

E-Print Network (OSTI)

Proton radiography is used for advanced hydrotesting as a new type radiography technology due to its powerful penetration capability and high detection efficiency. A new proton radiography terminal will be developed to radiograph static samples at Institute of Modern Physics of Chinese Academy of Science (IMP-CAS). The proton beam with the maximum energy of 2.6 GeV will be produced by Heavy Ion Research Facility in Lanzhou-Cooling Storage Ring (HIRFL-CSR). The proton radiography terminal consists of the matching magnetic lens and the Zumbro lens system. In this paper, the design scheme and all optic parameters of this beam terminal for 2.6GeV proton energy are presented by simulating the beam optics using WINAGILE code. My-BOC code is used to test the particle tracking of proton radiography beam line. Geant4 code and G4beamline code are used for simulating the proton radiography system. The results show that the transmission efficiency of proton without target is 100%, and the effect of secondary particles ca...

Yan, Yan; Huang, Zhi-Wu; Wang, Jie; Yao, Ze-En; Wang, Jun-Run; Wei, Zheng; Yang, Jian-Cheng; Yuan, You-Jin

2015-01-01T23:59:59.000Z

107

Mobile Alternative Fueling Station Locator  

SciTech Connect

The Department of Energy's Alternative Fueling Station Locator is available on-the-go via cell phones, BlackBerrys, or other personal handheld devices. The mobile locator allows users to find the five closest biodiesel, electricity, E85, hydrogen, natural gas, and propane fueling sites using Google technology.

Not Available

2009-04-01T23:59:59.000Z

108

emergency operations | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Recapitalizing Our Infrastructure Countering Nuclear Terrorism About Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Congressional...

109

Termination of Safeguards on ULWBR Material  

SciTech Connect

The Department of Energy (DOE), Office of Environmental Management, has approved the disposition of 31 metric tons of Unirradiated Light Water Breeder Reactor (ULWBR) material in canisters stored within dry wells of the Underground Fuel Storage Facility at the Idaho Nuclear Technology and Engineering Center (INTEC). This unirradiated material consists primarily of ceramic pellets of thorium oxide in stainless steel cladding, but it also contains 300 kilograms of uranium that is 98 wt% U-233. The ULWBR material was not processed at the INTEC because it was incompatible with prior chemical separation schemes. Other economical recovery options have not been identified, and expressions of interest for consolidating the material with existing projects at other DOE sites have not been received. The U-233 could be used for producing the medical isotope Actinium-225, but the proof-of-principle demonstration and follow-on pilot program have not been developed to the point of requiring production quantities of U-233. Consequently, the selected disposition of the ULWBR material was burial as Low Level Waste at the Nevada Test Site (NTS), which required terminating safeguards controls for the contained Category II quantity of Attractiveness Level D special nuclear material (SNM). The requested termination followed the twelve point evaluation criteria of the Historical Defense Program Discard Guidance and included a security analysis for evaluating the risks of theft, diversion, and radiological sabotage associated with the material. Continuity of knowledge in the book inventory was assured by documenting that the original shippers measurements accurately reflected the quantities of materials received and that the ULWBR materials had remained under adequate physical protection and had been subject to periodic physical inventories. The method selected for substantiating the book values as the basis for terminating safeguards was the nondestructive assay used during physical inventories. Shipping arrangements included refurbishing a licensed cask to be reused over the duration of the termination process. An accompanying batching plan and shipping schedule were developed to accommodate multiple commercial shipments of Category III quantities of SNM in the selected cask, such that all canisters would be received at NTS prior to the expiration of the nonrenewable cask license.

Ivan R. Thomas; Ernest L. Laible

2008-07-01T23:59:59.000Z

110

Location-aware active signage  

E-Print Network (OSTI)

Three-dimensional route maps, which depict a path from one location to another, can be powerful tools for visualizing and communicating directions. This thesis presents a client-server architecture for generating and ...

Nichols, Patrick James, 1981-

2004-01-01T23:59:59.000Z

111

Integrated risk assessment for LNG terminals  

Science Journals Connector (OSTI)

Abstract This paper presents an integrated risk assessment framework for Liquefied Natural Gas (LNG) terminals. The basic steps for risk assessment are the following: a) hazard identification, b) accident sequence modeling, where logic models such as Event Trees and Fault Trees are developed c) data acquisition and parameter estimation, used to estimate frequencies of the initiating events, component unavailability and probabilities of human actions, d) accident sequence quantification, where all accident sequences are assessed, e) consequence assessment, where release, evaporation rate, radiation levels and overpressure owing to immediate or delayed ignition of LNG is performed and f) integration of results where risk indices are assessed. Risk assessment of an onshore and an offshore LNG terminal is performed, according to the basic methodological steps, and the distances where individual risk levels equal to 10?510?7/yr are assessed and presented in the form of individual contours. A section dedicated to I.A. Papazoglou, pioneer in Quantitative Risk Assessment both in the nuclear and chemical industry is also provided.

O.N. Aneziris; I.A. Papazoglou; M. Konstantinidou; Z. Nivolianitou

2014-01-01T23:59:59.000Z

112

Terminating Safeguards on Excess Special Nuclear Material: Defense TRU Waste Clean-up and Nonproliferation - 12426  

SciTech Connect

The Department of Energy (DOE) and the National Nuclear Security Administration (NNSA) manages defense nuclear material that has been determined to be excess to programmatic needs and declared waste. When these wastes contain plutonium, they almost always meet the definition of defense transuranic (TRU) waste and are thus eligible for disposal at the Waste Isolation Pilot Plant (WIPP). The DOE operates the WIPP in a manner that physical protections for attractiveness level D or higher special nuclear material (SNM) are not the normal operating condition. Therefore, there is currently a requirement to terminate safeguards before disposal of these wastes at the WIPP. Presented are the processes used to terminate safeguards, lessons learned during the termination process, and how these approaches might be useful for future defense TRU waste needing safeguards termination prior to shipment and disposal at the WIPP. Also described is a new criticality control container, which will increase the amount of fissile material that can be loaded per container, and how it will save significant taxpayer dollars. Retrieval, compliant packaging and shipment of retrievably stored legacy TRU waste has dominated disposal operations at WIPP since it began operations 12 years ago. But because most of this legacy waste has successfully been emplaced in WIPP, the TRU waste clean-up focus is turning to newly-generated TRU materials. A major component will be transuranic SNM, currently managed in safeguards-protected vaults around the weapons complex. As DOE and NNSA continue to consolidate and shrink the weapons complex footprint, it is expected that significant quantities of transuranic SNM will be declared surplus to the nation's needs. Safeguards termination of SNM varies due to the wide range of attractiveness level of the potential material that may be directly discarded as waste. To enhance the efficiency of shipping waste with high TRU fissile content to WIPP, DOE designed an over-pack container, similar to the pipe component, called the criticality control over-pack, which will significantly enhance the efficiency of disposal. Hundreds of shipments of transuranic SNM, suitably packaged to meet WIPP waste acceptance criteria and with safeguards terminated have been successfully emplaced at WIPP (primarily from the Rocky Flats site clean-up) since WIPP opened. DOE expects that thousands more may eventually result from SNM consolidation efforts throughout the weapons complex. (authors)

Hayes, Timothy [Los Alamos National Laboratory, Carlsbad Operations Group (United States); Nelson, Roger [Department Of Energy, Carlsbad Operations Office (United States)

2012-07-01T23:59:59.000Z

113

Operations | National Nuclear Security Administration  

NLE Websites -- All DOE Office Websites (Extended Search)

| National Nuclear Security Administration | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Operations Home > About Us > Our Programs > Emergency Response > Responding to Emergencies > Operations Operations NNSA's Emergency Response Operations program acts as the headquarters command and control, functioning as the coordinating focal point for all

114

Operations | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

| National Nuclear Security Administration | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Operations Home > About Us > Our Programs > Emergency Response > Responding to Emergencies > Operations Operations NNSA's Emergency Response Operations program acts as the headquarters command and control, functioning as the coordinating focal point for all

115

OPERATIONS (OPS)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

OPS) OPS) OBJECTIVE OPS.1 The formality and discipline of operations is adequate to conduct work safely and programs are in place to maintain this formality and discipline. (CR 13) Scope: The Conduct of Operations Program was evaluated during the recent KE Basin FTS ORR and was found to be adequately implemented. Based on this result and the subsequent program enhancements, the scope of the review is to be limited to the SWS operating and maintenance evolutions. Criteria * Programmatic elements of conduct of operations are in place for SWS operations. (DOE Order 5480.19) * The SWS operations personnel adequately demonstrate the principles of conduct of operations requirements during the shift performance period. (DOE Order 5480.19)

116

Operation Diagnostics: Use of Visualization Techniques and Operation  

NLE Websites -- All DOE Office Websites (Extended Search)

Operation Diagnostics: Use of Visualization Techniques and Operation Operation Diagnostics: Use of Visualization Techniques and Operation Patterns to Verify and Optimize Dynamic Building and System Operation Speaker(s): Oliver Baumann Date: December 7, 2004 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Peng Xu Building automation systems (BAS) and building energy management systems (BEMS) have been used in modern edifices for the last 2 decades. These systems measure, process, and monitor a huge amount of data to operate the building and systems more or less properly. Often, the data is only used to signal failures or break-downs of systems or components. Further information of the data to analyze and diagnose the building operation is not used due to the lack of analysis methods and tools. Within the Operation Diagnostics, different visualization techniques are applied to

117

Reducing Heavy-Haul Railcar Maintenance Costs and Improving Terminal Performance Using Technology: A Lean Production Approach  

E-Print Network (OSTI)

operations. This research applies Lean Manufacturing methods to the railcar maintenance process industries to improve production and manufacturing efficiency. In the 2000s, various production management with terminal dwell [3,4]. In addition, Logan suggested that for every 15% reduction in systemwide average

Illinois at Urbana-Champaign, University of

118

IEEE TRANSACTIONS ON COMPUTERS, VOL. 47, NO. 10, OCTOBER 1998 1073 The InfoPad Multimedia Terminal: A Portable  

E-Print Network (OSTI)

designed for portable stand-alone operation. The requirements to reduce the weight and energy consumption- sary to reduce the energy consumption, weight and cost of the end-user device as much a the terminal to have the port- ability of a paper notebook (1 lb, 8.5" x 11") while still being able to support

Han, Richard Y.

119

Location logistics of industrial facilities  

E-Print Network (OSTI)

is not growing rapidly or 1s very small, they may not carry a staff from wh1ch the necessary people for a 25 s1te selection team can be drawn. Also, quite possibly, a company may not be involved in the site selection process for expansion. Instead, they may... location and site selection. This data was gathered through library research, atten- dance of various industr1al development conferences, sol1citation of mater1als from individuals currently involved with industrial facil1ties location, and various...

Hammack, William Eugene

2012-06-07T23:59:59.000Z

120

Major DOE Biofuels Project Locations  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Biofuels Project Locations Biofuels Project Locations BlueFire Ethanol Biochemical Municipal Solid Waste (Mecca, CA) Poet Biochemical Corn Cob/Corn Fiber (Emmetsburg, IA) Lignol Biochemical Woody Biomass- Ag Residues (Grand Junction, CO) ICM Biochemical Switchgrass, Forage Sorghum, Stover (St. Joseph, MO) Abengoa Biochemica Agricultural Residue (Hugoton, KS) DOE Joint Bioenergy Institute (Berkeley, CA) DOE Great Lakes Bioenergy Research Center (Madison, WI) DOE Bioenergy Science Center (Oak Ridge, TN) NewPage Thermochemical Woody Biomass - Mill Residues (Wisconsin Rapids, WI) Range Fuels Thermochemical Woody Waste (Soperton, GA) DSM Innovation Center Biochemical Various (Parsippany, NJ) Novozymes Biochemical Various (Davis, CA) Genencor Biochemical Various (Palo Alto, CA) Verenium Corp Biochemical Various (San Diego, CA)

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Nevada Operations Office  

Office of Legacy Management (LM)

Nevada Operations Office Nevada Operations Office t' . 0. Box 14100, Las Vegas, NV 89114-4100 Lt. Col. Kent J. Rohlof; USAF Commander 554th Civil Engineering Support Squadron (TAC) Nellis Air Force Base, NV 89191 DISPOSAL OF LIQUID RADIOACTIVE WASTE--NELLIS AIR FORCE BASE Layton O'Neill and Thomas Graham of my office recently visited two sites at Nellis AFB, Area II, identified as locations for burial of radioactive waste. The purpose of this visit was to visually inspect the physical status of the sites, one identified as the location of the subject liquid wastes. Numerous readings were made with a hand-held Ludlum Model 125 Micro-R meter, for the purpose of personnel radiation protection walking into the controlled, posted radioactive waste compounds. No readings were above background.

122

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

June 20, 2011 June 20, 2011 CX-006372: Categorical Exclusion Determination Well Installations at R-Area Operable Unit CX(s) Applied: B3.1 Date: 06/20/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office June 15, 2011 CX-006373: Categorical Exclusion Determination Connect 735-11A to the Central Plant Chilled Water System CX(s) Applied: B1.3 Date: 06/15/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office June 14, 2011 CX-006375: Categorical Exclusion Determination Replace Transfer Lines with Spare Lines CX(s) Applied: B1.3 Date: 06/14/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office June 14, 2011 CX-006374: Categorical Exclusion Determination

123

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

March 15, 2013 March 15, 2013 CX-010126: Categorical Exclusion Determination Operation of Induction Furnace Fabrication Lab CX(s) Applied: B3.6 Date: 03/15/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office March 15, 2013 CX-010125: Categorical Exclusion Determination Microfluidics for Advanced Separation and Ultrasensitive Detection CX(s) Applied: B3.6 Date: 03/15/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office March 15, 2013 CX-010131: Categorical Exclusion Determination Replacement of the 254-13H Safety Significant (SS) Standby Diesel Generator CX(s) Applied: B1.25 Date: 03/15/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office March 15, 2013 CX-010130: Categorical Exclusion Determination Mechanical Isolation of Plant Air System at TNX

124

Categorical Exclusion Determinations: Idaho Operations Office | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

January 25, 2011 January 25, 2011 CX-005187: Categorical Exclusion Determination Hex Block Shipment Project CX(s) Applied: B3.6 Date: 01/25/2011 Location(s): Idaho Office(s): Nuclear Energy, Idaho Operations Office January 5, 2011 CX-004926: Categorical Exclusion Determination Radioactive Waste Management Complex ? Analytical Laboratory Operations CX(s) Applied: B3.1 Date: 01/05/2011 Location(s): Idaho Office(s): Nuclear Energy, Idaho Operations Office December 10, 2010 CX-004645: Categorical Exclusion Determination CPP-663 Heating, Ventilation and Air Conditioning Systems Upgrade CX(s) Applied: B2.1 Date: 12/10/2010 Location(s): Idaho Office(s): Idaho Operations Office November 16, 2010 CX-004561: Categorical Exclusion Determination Idaho Nuclear Technology and Engineering Center - Light Water Breeder

125

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

August 11, 2009 August 11, 2009 CX-000513: Categorical Exclusion Determination Cone Penetration Test sampling at ECODS (Early Construction and Operational Disposal Sites) B3 and B5 CX(s) Applied: B3.1 Date: 08/11/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office August 5, 2009 CX-000511: Categorical Exclusion Determination Isolation of Domestic Water Line, 782-4G CX(s) Applied: B1.3 Date: 08/05/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office August 5, 2009 CX-000512: Categorical Exclusion Determination Tree Removal and Chipping at P-Area Ash Basin and R-Area Ash Basin and P-007 Outfall Date: 08/05/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office

126

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

9, 2012 9, 2012 CX-008639: Categorical Exclusion Determination Establish Laydown Yard East of 281-3F CX(s) Applied: B1.15 Date: 05/29/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office May 29, 2012 CX-008638: Categorical Exclusion Determination Excavate to Repair Underground Domestic Water Leak between Tanks 5 and 7 CX(s) Applied: B1.3 Date: 05/29/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office May 29, 2012 CX-008637: Categorical Exclusion Determination Operation and Maintenance of Inductively Coupled Plasma Mass Spectrometry Method in 773, B142 CX(s) Applied: B3.6 Date: 05/29/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office May 29, 2012 CX-008636: Categorical Exclusion Determination Analysis of Organic Species by Gas Chromatography (GC) and Gas

127

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

May 21, 2013 May 21, 2013 CX-010489: Categorical Exclusion Determination Salt Batch 7 Qualification CX(s) Applied: B3.6 Date: 05/21/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office May 14, 2013 CX-010497: Categorical Exclusion Determination Electrical Operations to Perform Yard Maintenance in Electrical Substations CX(s) Applied: B1.3 Date: 05/14/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office May 14, 2013 CX-010496: Categorical Exclusion Determination Corrosion Tests on Carbon Steel Exposed to Oxalic Acid and a Sludge Simulant CX(s) Applied: B3.6 Date: 05/14/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office May 14, 2013 CX-010495: Categorical Exclusion Determination Advanced Fuel Cycle Initiative (AFCI) Am/Cm Separations

128

Do not exceed the operating input power, voltage, and current level and signal type appropriate for the instrument being used, refer to  

E-Print Network (OSTI)

operation. - Instrument generates high temperature or electrical shock during operation. - Power cable, plug below, immediately terminate operation and disconnect the power cable. Contact your local Agilent;Herstellerbescheinigung GER AUSCHEMISSION LpA Manufacturer

Anlage, Steven

129

Building Address Locations -Assumes entire  

E-Print Network (OSTI)

Housman Building 80 E. Concord St R BU School of Medicine, Instructional Building 80 E. Concord St L BU JBuilding Address Locations - Assumes entire building unless noted Designation Submit through* 560, 4 BU Crosstown Center 801 Massachusetts Ave Floor 1, 2 BMC BCD Building 800 Harrison Avenue BCD BMC

Guenther, Frank

130

The impact on transmission line terminations on radiated emissions.  

E-Print Network (OSTI)

??Terminating transmission lines at either the source or the load end with a damping resistor is frequently used to improve the signal integrity of clock (more)

Wong, Wei-Juet

2007-01-01T23:59:59.000Z

131

Self-terminating diffraction gates femtosecond X-ray nanocrystallograp...  

NLE Websites -- All DOE Office Websites (Extended Search)

Self-terminating diffraction gates femtosecond X-ray nanocrystallography measurements Authors: Barty, A., Caleman, C., Aquila, A., Timneanu, N., Lomb, L., White, T. A., Andreasson,...

132

Application of the Continuous Commissioning Process at a K-12 School Distrcit Located in Cental Texas  

E-Print Network (OSTI)

-10-09 Proceedings of the 13th International Conference for Enhanced Building Operations, Montreal, Quebec, October 8-11, 2013 distributed HVAC systems. Air-side systems generally include various types of air handling units (AHUs), fan coil units (FCUs), terminal...

Shah, M.; Sun, Y.; Lander, W.; Yagua, C.; Watt, J.; Oh, S.; Claridge, D.

2013-01-01T23:59:59.000Z

133

SPEAR Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Interface 1113 N. Kurita J. Langton Vacuum TSP's 1120 J. Corbett A. Terebilo MATLAB Applications - Basics 1121 F. Rafael Booster Kicker Upgrade, Operation Manual 1121...

134

operations center  

National Nuclear Security Administration (NNSA)

1%2A en Operations Center http:nnsa.energy.govaboutusourprogramsemergencyoperationscounterterrorismoperationscenter

...

135

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savannah River Operations Savannah River Operations Office Categorical Exclusion Determinations: Savannah River Operations Office Categorical Exclusion Determinations issued by Savannah River Operations Office. DOCUMENTS AVAILABLE FOR DOWNLOAD September 10, 2013 CX-010669: Categorical Exclusion Determination 484-17D Coal Yard Remediation CX(s) Applied: B6.1 Date: 06/07/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 1, 2013 CX-010837: Categorical Exclusion Determination Disassembly, Relocation, and Reassembly of a Metal-framed Quonset Hut CX(s) Applied: B1.22 Date: 08/01/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 1, 2013 CX-010836: Categorical Exclusion Determination Subcontractor Roof Repair at 717-12S CX(s) Applied: B1.3

136

Battery system including batteries that have a plurality of positive terminals and a plurality of negative terminals  

DOE Patents (OSTI)

A lithium battery for use in a vehicle includes a container, a plurality of positive terminals extending from a first end of the lithium battery, and a plurality of negative terminals extending from a second end of the lithium battery. The plurality of positive terminals are provided in a first configuration and the plurality of negative terminals are provided in a second configuration, the first configuration differing from the second configuration. A battery system for use in a vehicle may include a plurality of electrically connected lithium cells or batteries.

Dougherty, Thomas J; Symanski, James S; Kuempers, Joerg A; Miles, Ronald C; Hansen, Scott A; Smith, Nels R; Taghikhani, Majid; Mrotek, Edward N; Andrew, Michael G

2014-01-21T23:59:59.000Z

137

station locations | OpenEI  

Open Energy Info (EERE)

00 00 Varnish cache server Browse Upload data GDR 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142288500 Varnish cache server station locations Dataset Summary Description Alternative fueling stations are located throughout the United States and their availability continues to grow. The Alternative Fuels Data Center (AFDC) maintains a website where you can find alternative fuels stations near you or on a route, obtain counts of alternative fuels stations by state, Source Alternative Fuels Data Center Date Released December 13th, 2010 (4 years ago) Date Updated December 13th, 2010 (4 years ago) Keywords alt fuel alternative fuels alternative fuels stations biodiesel CNG compressed natural gas E85 Electricity ethanol

138

Isolated fungal promoters and gene transcription terminators and methods of protein and chemical production in a fungus  

DOE Patents (OSTI)

The present invention encompasses isolated gene regulatory elements and gene transcription terminators that are differentially expressed in a native fungus exhibiting a first morphology relative to the native fungus exhibiting a second morphology. The invention also encompasses a method of utilizing a fungus for protein or chemical production. A transformed fungus is produced by transforming a fungus with a recombinant polynucleotide molecule. The recombinant polynucleotide molecule contains an isolated polynucleotide sequence linked operably to another molecule comprising a coding region of a gene of interest. The gene regulatory element and gene transcription terminator may temporally and spatially regulate expression of particular genes for optimum production of compounds of interest in a transgenic fungus.

Dai, Ziyu (Richland, WA); Lasure, Linda L. (Fall City, WA); Magnuson, Jon K. (Pasco, WA)

2008-11-11T23:59:59.000Z

139

Isolated Fungal Promoters and Gene Transcription Terminators and Methods of Protein and Chemical Production in a Fungus  

DOE Patents (OSTI)

The present invention encompasses isolated gene regulatory elements and gene transcription terminators that are differentially expressed in a native fungus exhibiting a first morphology relative to the native fungus exhibiting a second morphology. The invention also encompasses a method of utilizing a fungus for protein or chemical production. A transformed fungus is produced by transforming a fungus with a recombinant polynucleotide molecule. The recombinant polynucleotide molecule contains an isolated polynucleotide sequence linked operably to another molecule comprising a coding region of a gene of interest. The gene regulatory element and gene transcription terminator may temporally and spatially regulate expression of particular genes for optimum production of compounds of interest in a transgenic fungus.

Dai, Ziyu (Richland, WA); Lasure, Linda L. (Fall City, WA); Magnuson, Jon K. (Pasco, WA)

2008-11-11T23:59:59.000Z

140

Environmental Assessment on the leasing of the Strategic Petroleum Reserve, St. James Terminal, St. James Parish, Louisiana  

SciTech Connect

The US Department of Energy (DOE) proposes to lease the Strategic Petroleum Reserve`s (SPR) St. James Terminal to private industry. The St. James Terminal consists of six storage tanks, a pumping station, two maine docks and ancillary facilities. DOE believes that the St. James Terminal presents an opportunity to establish a government- industry arrangement that could more effectively use this asset to serve the nations`s oil distribution needs, reduce the operational cost of the SPR, and provide a source of revenue for the Government. DOE solicited interest in leasing its distribution facilities in a notice published March 16, 1994. In response, industry has expressed interest in leasing the St. James Terminal, as well as several DOE pipelines, to enhance the operation of its own facilities or to avoid having to construct new ones. Under such a lease, industry use would be subordinate to DOE use in the event of a national energy emergency. This Environmental Assessment describes the proposed leasing operation, its alternatives, and potential environmental impacts. Based on this analyses, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) OF 1969 and has issued the Finding of No Significant Impact (FONSI).

NONE

1995-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Visual Simulation of Offshore Liquefied Natural Gas (LNG) Terminals  

E-Print Network (OSTI)

Visual Simulation of Offshore Liquefied Natural Gas (LNG) Terminals in a Decision-Making Context1, Berkeley. 3/ Liquified Natural Gas Act Stats, 1977, Chap. 855, Page 2506 (effective Sept. 17, 1977 potential offshore Liquified Natural Gas (LNG) sites and the types of terminals that might occupy those

Standiford, Richard B.

142

Columbia River : Terminal Fisheries Research Report : Annual Report 1994.  

SciTech Connect

In 1993 the Northwest Power Planning Council recommended in its Strategy for Salmon that terminal fishing sites be identified and developed. The Council called on the Bonneville Power Administration to fund a 10-year study to investigate the feasibility of creating and expanding terminal known stock fisheries in the Columbia River Basin.

Hirose, Paul; Miller, Marc; Hill, Jim

1996-12-01T23:59:59.000Z

143

LM79XX Series 3-Terminal Negative Regulators  

E-Print Network (OSTI)

LM79XX Series 3-Terminal Negative Regulators General Description The LM79XX series of 3-terminal external component -- a compensation ca- pacitor at the output. The LM79XX series is packaged in the TO-220 conditions. Low ground pin current of the LM79XX series allows output voltage to be easily boosted above

Berns, Hans-Gerd

144

Termination of Just/Fair Computations in Term Rewriting  

E-Print Network (OSTI)

Termination of Just/Fair Computations in Term Rewriting Salvador Lucas a Jos´e Meseguer b a for prov- ing termination of concurrent systems under fairness assumptions. Specifically, Salvador Lucas-02-1-0715 and NSF Grant CCR-0234524. Email addresses: slucas@dsic.upv.es (Salvador Lucas), meseguer@cs.uiuc.edu (Jos

Lucas, Salvador

145

Performance of ECM controlled VAV fan powered terminal units  

E-Print Network (OSTI)

2006). The airflow and power consumption performance models had an R2 equal to 0.990 or greater for every terminal unit tested. An air leakage model was employed to account for leakage in the parallel designed VAV terminal units when the internal fan...

Cramlet, Andrew Charles

2009-05-15T23:59:59.000Z

146

Density of neutral interstellar hydrogen at the termination shock from Ulysses pickup ion observations  

E-Print Network (OSTI)

By reevaluating a 13-month stretch of Ulysses SWICS H pickup ion measurements near 5 AU close to the ecliptic right after the previous solar minimum, this paper presents a determination of the neutral interstellar H density at the solar wind termination shock and implications for the density and ionization degree of hydrogen in the LIC. The density of neutral interstellar hydrogen at the termination shock was determined from the local pickup ion production rate as obtained close to the cut-off in the distribution function at aphelion of Ulysses. As shown in an analytical treatment for the upwind axis and through kinetic modeling of the pickup ion production rate at the observer location, with variations in the ionization rate, radiation pressure, and the modeling of the particle behavior, this analysis turns out to be very robust against uncertainties in these parameters and the modeling. Analysis using current heliospheric parameters yields the H density at the termination shock equal to $0.087\\pm0.022$ cm$^{-3}$, including observational and modeling uncertainties.

M. Bzowski; E. Moebius; S. Tarnopolski; V. Izmodenov; G. Gloeckler

2007-10-08T23:59:59.000Z

147

Tunable atomic termination in nano-necklace BiFeO{sub 3}  

SciTech Connect

We investigate the growth kinetics of BiFeO{sub 3} (BFO) nano-necklace based on first principles modeling and electrospinning experiments. A two-step layered growth mechanism is proposed to control the atomic termination of each nano-necklace. X-ray diffraction (XRD) results agree well with our model predictions; (1) samples calcined at 500 and 550?C consist of FeO{sub 2} (F-F) terminated nano-necklace, (2) samples calcined at 650?C consist of either BiO (B-B) or BiO and FeO{sub 2} (B-F) terminated ones. The XRD diffraction peaks are located at lower 2? values with a magnetic moment of 3.0?emu/g for the former and at higher 2? values with a decrease in the magnetic moment to 0.4?emu/g for the later samples. The activation energy associated with the growth of the nano-necklaces was experimentally determined to be 0.37?eV/atom. This study provides fundamental understanding for the long-sought layer-by-layer assembly of BFO nanostructures.

Sobhan, Mushtaq; Xu, Qiang; Yang, Qian; Anariba, Franklin; Wu, Ping, E-mail: wuping@sutd.edu.sg [Entropic Interface Group (EIG), Engineering Product Development, Singapore University of Technology and Design (SUTD), 20 Dover Drive (Singapore)

2014-02-03T23:59:59.000Z

148

A survey of computational location privacy  

Science Journals Connector (OSTI)

This is a literature survey of computational location privacy, meaning computation-based privacy mechanisms that treat location data as geometric information. This definition includes privacy-preserving algorithms like anonymity and obfuscation as well ... Keywords: Context, Location, Privacy

John Krumm

2009-08-01T23:59:59.000Z

149

Location and Hours | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Location and Hours Location The ORNL Research Library is located off the central corridor of Bldg. 4500N on the main ORNL campus. Hours The library is open 24 hours, seven days a...

150

Design operators  

E-Print Network (OSTI)

Design operators is a thesis that investigates the nature and characteristics of the design process by examining the interaction of computation with architectural design. The effects of the introduction of these media in ...

Dritsas, Stylianos, 1978-

2004-01-01T23:59:59.000Z

151

Business Operations  

Office of Energy Efficiency and Renewable Energy (EERE)

The Office of Business Operations is the central organization for all Office of Energy Efficiency and Renewable Energy (EERE) business products, processes, and systems. The three main offices of...

152

Operating Costs  

Directives, Delegations, and Requirements

This chapter is focused on capital costs for conventional construction and environmental restoration and waste management projects and examines operating cost estimates to verify that all elements of the project have been considered and properly estimated.

1997-03-28T23:59:59.000Z

153

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

November 29, 2012 November 29, 2012 CX-009607: Categorical Exclusion Determination 772-F Low-Activity Drain (LAD) Discharge Header Modification CX(s) Applied: B1.3 Date: 11/29/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office November 29, 2012 CX-008651: Categorical Exclusion Determination Dismantle and Remove (D&R) and Replace 773-A D-Wing Air Handling and Condensing Units CX(s) Applied: B1.3 Date: 05/17/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office November 29, 2012 CX-009608: Categorical Exclusion Determination Refurbish 607-53C Sanitary Sewer Lift Station CX(s) Applied: B1.3 Date: 11/29/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office November 27, 2012 CX-009611: Categorical Exclusion Determination

154

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

June 23, 2009 June 23, 2009 CX-000497: Categorical Exclusion Determination F-Canyon Complex Deactivation CX(s) Applied: B1.28 Date: 06/23/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office June 15, 2009 CX-000495: Categorical Exclusion Determination M-Area Chemical Oxidation (MACO) - Installation of Southern Sector Coreholes and Monitoring Wells Date: 06/15/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office June 15, 2009 CX-000496: Categorical Exclusion Determination F Area Hazardous Waste Management Facility Silver Chloride Solution Injection Wells CX(s) Applied: B6.2 Date: 06/15/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office

155

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

July 31, 2013 July 31, 2013 CX-010844: Categorical Exclusion Determination Subcontractor Repair of Leak Over Entry Door #1 at 703-B CX(s) Applied: B1.3 Date: 07/31/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office July 30, 2013 CX-010846: Categorical Exclusion Determination Install Stud, Shims, and Nut in the L-Basin 70-Ton Cask Lid Support Structure CX(s) Applied: B2.5 Date: 07/30/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office July 23, 2013 CX-010850: Categorical Exclusion Determination Install Well Pump into the F-Tank Farm Catch Tank FL-241901-WTS-TK-1 CX(s) Applied: B1.3 Date: 07/23/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office July 23, 2013 CX-010849: Categorical Exclusion Determination

156

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

September 2, 2009 September 2, 2009 CX-000521: Categorical Exclusion Determination Cut and Cap #325 Steam Supply Header, 261-H Consolidated Incineration Facility CX(s) Applied: B1.27 Date: 09/02/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office September 2, 2009 CX-000520: Categorical Exclusion Determination 690-N (Ford Building) Fire System Isolation and Sanitary Sewer Grouting CX(s) Applied: B1.27 Date: 09/02/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office September 1, 2009 CX-000519: Categorical Exclusion Determination E-Area Box Remediation Project CX(s) Applied: B6.6 Date: 09/01/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office

157

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

August 13, 2013 August 13, 2013 CX-011158: Categorical Exclusion Determination Subcontractor Repair of Roof Leaks at 717-11A CX(s) Applied: B1.3 Date: 08/13/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 13, 2013 CX-011157: Categorical Exclusion Determination Subcontractor Roof Repairs in Telecom Room at 702-C CX(s) Applied: B1.3 Date: 08/13/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 8, 2013 CX-011163: Categorical Exclusion Determination Subcontractor Repair of Roof Leaks at 730-4B CX(s) Applied: B1.3 Date: 08/08/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 8, 2013 CX-011162: Categorical Exclusion Determination Subcontractor Repair of Roof Leaks at 730-1B CX(s) Applied: B1.3

158

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

August 9, 2010 August 9, 2010 CX-003633: Categorical Exclusion Determination Install Platform and Stairs at F-10 Outfall CX(s) Applied: B2.3 Date: 08/09/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office August 4, 2010 CX-003635: Categorical Exclusion Determination D-Area Chemical Truck Unloading Station CX(s) Applied: B2.5 Date: 08/04/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office August 4, 2010 CX-003636: Categorical Exclusion Determination 484-D Sump Discharge Line Installation CX(s) Applied: B1.3 Date: 08/04/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office July 30, 2010 CX-003640: Categorical Exclusion Determination Howard T. Ricketts Laboratory (HTRL) Lab 134 CX(s) Applied: B3.6

159

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

April 20, 2011 April 20, 2011 CX-005766: Categorical Exclusion Determination Filter Testing with Static Test Cell CX(s) Applied: B3.6 Date: 04/20/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office April 19, 2011 CX-005769: Categorical Exclusion Determination Dismantle and Removal (D&R) and Enhance Chemical Cleaning (ECC) on Waste Tank 8F (General) CX(s) Applied: B1.28 Date: 04/19/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office April 15, 2011 CX-005771: Categorical Exclusion Determination Install Alternate Diesel Generator and Tie-In Connection for HB-Line CX(s) Applied: B2.5 Date: 04/15/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office

160

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

April 16, 2013 April 16, 2013 CX-010322: Categorical Exclusion Determination Research and Development Welding and Brazing Sample Preparation and Activities in Building 723-A CX(s) Applied: B3.6 Date: 04/16/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office April 16, 2013 CX-010321: Categorical Exclusion Determination Destructive Evaluation of Plutonium Storage Can Bundles CX(s) Applied: B3.6 Date: 04/16/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office April 16, 2013 CX-010320: Categorical Exclusion Determination Corrosion Testing in Aqueous Solutions CX(s) Applied: B3.6 Date: 04/16/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office April 15, 2013 CX-010324: Categorical Exclusion Determination 772-F Chase 174 Sprinkler Modification

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

February 23, 2010 February 23, 2010 CX-001128: Categorical Exclusion Determination Closure of 607-10G Septic Tank (Served 661-G) CX(s) Applied: B1.27 Date: 02/23/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office February 23, 2010 CX-001127: Categorical Exclusion Determination Ballistic Resistant Enclosure Hatch Counterbalance CX(s) Applied: B2.5 Date: 02/23/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office February 23, 2010 CX-000878: Categorical Exclusion Determination 293-F Stack Risk Reduction Project CX(s) Applied: B1.28 Date: 02/23/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office February 23, 2010

162

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

July 24, 2012 July 24, 2012 CX-009067: Categorical Exclusion Determination Deactivation and Decommissioning of the D-Area Detritiation Cells and Relocation of Associated Handi-Houses CX(s) Applied: B1.23 Date: 07/24/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office July 24, 2012 CX-009066: Categorical Exclusion Determination Characterization of Downgradient Volatile Organic Compounds Plume and Installation of Monitoring Well CX(s) Applied: B3.1 Date: 07/24/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office July 24, 2012 CX-009065: Categorical Exclusion Determination Installation of Sentinel Wells ASB011B/011C for A-2 Air Stripper Shutdown CX(s) Applied: B3.1 Date: 07/24/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office

163

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

October 25, 2010 October 25, 2010 CX-004445: Categorical Exclusion Determination Waste Treatment Plant Secondary Waste Radioactive Fluidized Bed Steam Reforming (Module A) CX(s) Applied: B3.6 Date: 10/25/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office October 15, 2010 CX-004450: Categorical Exclusion Determination Plutonium Glass Sectioning CX(s) Applied: B3.6 Date: 10/15/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office October 15, 2010 CX-004449: Categorical Exclusion Determination Bench Scale Testing to Provide Data on Precipitation Control in the Cesium Nitric Acid Recovery Process CX(s) Applied: B3.6 Date: 10/15/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office October 15, 2010

164

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

December 10, 2010 December 10, 2010 CX-004837: Categorical Exclusion Determination Measurement of Compressive Strength CX(s) Applied: B3.6 Date: 12/10/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office December 7, 2010 CX-004826: Categorical Exclusion Determination Piezometer Well Installation for 1,4-Dioxane Monitoring CX(s) Applied: B3.1 Date: 12/07/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office December 7, 2010 CX-004824: Categorical Exclusion Determination Dismantle and Remove Tank 6 Riser 7 for Waste Determination (WD) Sampling CX(s) Applied: B1.3 Date: 12/07/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office December 7, 2010 CX-004823: Categorical Exclusion Determination Consolidation of K- and L-Area Heavy Water in C-Area

165

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

January 24, 2011 January 24, 2011 CX-005090: Categorical Exclusion Determination Stairway to FM-1H CX(s) Applied: B2.3 Date: 01/24/2011 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office January 21, 2011 CX-005109: Categorical Exclusion Determination Y589, Mobile Digital Radiography Identification System - Station CX(s) Applied: B1.15 Date: 01/21/2011 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office January 20, 2011 CX-005108: Categorical Exclusion Determination Thin Films for Whisker Growth CX(s) Applied: B3.6 Date: 01/20/2011 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office January 19, 2011 CX-005107: Categorical Exclusion Determination Karl Fisher Titration CX(s) Applied: B3.6 Date: 01/19/2011

166

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

November 29, 2010 November 29, 2010 CX-004808: Categorical Exclusion Determination Flowsheet Evaluation for the Neutralization of High Aluminum ? Low Uranium Used Nuclear Fuel (UNF) Solution CX(s) Applied: B3.6 Date: 11/29/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office November 29, 2010 CX-004809: Categorical Exclusion Determination Reactive Gas Reprocessing of Used Nuclear Fuel Simulants CX(s) Applied: B3.6 Date: 11/29/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office November 29, 2010 CX-004806: Categorical Exclusion Determination Volume Measurement of Solids by Gas Pycnometry CX(s) Applied: B3.6 Date: 11/29/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office November 12, 2010 CX-004805: Categorical Exclusion Determination

167

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

December 11, 2009 December 11, 2009 CX-000815: Categorical Exclusion Determination Hydrogen Technology Laboratory 140 - Chromatography, Wet Laboratory CX(s) Applied: B3.6 Date: 12/11/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office December 8, 2009 CX-000819: Categorical Exclusion Determination Thin-Film Development Laboratory CX(s) Applied: B3.6 Date: 12/08/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office December 8, 2009 CX-000820: Categorical Exclusion Determination Vacuum Induction Melting of Metals CX(s) Applied: B3.6 Date: 12/08/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office December 8, 2009 CX-000818: Categorical Exclusion Determination

168

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

July 20, 2012 July 20, 2012 CX-009070: Categorical Exclusion Determination A-Area Alternate Fire Water Supply CX(s) Applied: B1.3 Date: 07/20/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office July 20, 2012 CX-009069: Categorical Exclusion Determination Remove and Dispose of 107 A & B Tanks and Support Structure CX(s) Applied: B6.1 Date: 07/20/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office July 20, 2012 CX-009068: Categorical Exclusion Determination Hydrogen Charging Tritium Contaminated Metals CX(s) Applied: B3.6 Date: 07/20/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office July 16, 2012 CX-009077: Categorical Exclusion Determination F-Area Infrasturcture Improvement CX(s) Applied: B1.23 Date: 07/16/2012

169

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

August 30, 2012 August 30, 2012 CX-009100: Categorical Exclusion Determination Cooling Tower Water Sampling and Analysis for Legionella Pneumophila Density CX(s) Applied: B3.6 Date: 08/30/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office August 29, 2012 CX-009106: Categorical Exclusion Determination Dismantle/Remove Vacuum System and Related Equipment in 772-F CX(s) Applied: B1.3 Date: 08/29/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office August 29, 2012 CX-009105: Categorical Exclusion Determination 284-H Track Coal Hopper Pit Modifications CX(s) Applied: B1.28 Date: 08/29/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office August 29, 2012 CX-009104: Categorical Exclusion Determination Infrastructure Modification for the Mobile Plutonium Facility (MPF) at the

170

Categorical Exclusion Determinations: Idaho Operations Office | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

March 15, 2010 March 15, 2010 CX-001231: Categorical Exclusion Determination Test Reactor Area-653 Heating, Ventilation, Air Conditioning Modifications CX(s) Applied: B2.1, B2.5 Date: 03/15/2010 Location(s): Idaho Office(s): Idaho Operations Office, Nuclear Energy March 15, 2010 CX-001230: Categorical Exclusion Determination Replace 200,000 Gallon Water Storage Tank at Material Fuels Complex CX(s) Applied: B1.15 Date: 03/15/2010 Location(s): Idaho Office(s): Idaho Operations Office, Nuclear Energy March 11, 2010 CX-001229: Categorical Exclusion Determination Characterization of Fluidized Beds by Pressure Fluctuation Analysis CX(s) Applied: B3.6 Date: 03/11/2010 Location(s): Idaho Office(s): Idaho Operations Office, Nuclear Energy February 23, 2010 CX-000865: Categorical Exclusion Determination

171

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

June 20, 2013 June 20, 2013 CX-010655: Categorical Exclusion Determination Roof Repair on Crane Maintenance Area Roof CX(s) Applied: B1.3 Date: 06/20/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office June 18, 2013 CX-010657: Categorical Exclusion Determination Western Sector Treatment System Soil Vapor Extraction Wells CX(s) Applied: B3.1 Date: 06/18/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office June 18, 2013 CX-010656: Categorical Exclusion Determination Stormwater Drainage Repair CX(s) Applied: B1.3 Date: 06/18/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office June 17, 2013 CX-010662: Categorical Exclusion Determination Reroute Diesel Water Cooling Line at 241-125H CX(s) Applied: B1.3 Date: 06/17/2013

172

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

March 10, 2010 March 10, 2010 CX-001373: Categorical Exclusion Determination Analytical Development Tritium Support Laboratory for Mass Spectroscopy, Infrared Spectroscopy, and Raman CX(s) Applied: B3.6 Date: 03/10/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office March 10, 2010 CX-001372: Categorical Exclusion Determination On-Dock Rail Straddle Portal Prototype Project, Y580 CX(s) Applied: B3.6 Date: 03/10/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office March 4, 2010 CX-001129: Categorical Exclusion Determination Cut and Cap Firewater Line Tap-Off Near 714-7N CX(s) Applied: B1.3 Date: 03/04/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office

173

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

July 20, 2011 July 20, 2011 CX-006620: Categorical Exclusion Determination Relocate Hydroburst System from 238-H to 234-7H CX(s) Applied: B1.31 Date: 07/20/2011 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office July 18, 2011 CX-006619: Categorical Exclusion Determination Install Seventeen Monitoring Wells Around 715-D CX(s) Applied: B3.1 Date: 07/18/2011 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office July 18, 2011 CX-006618: Categorical Exclusion Determination Disable F-Tank Farm (FTF) Air Compressor Sequencer CX(s) Applied: B1.3 Date: 07/18/2011 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office July 18, 2011 CX-006617: Categorical Exclusion Determination E Area Fire Water Extension CX(s) Applied: B1.15

174

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

June 27, 2012 June 27, 2012 CX-008614: Categorical Exclusion Determination Repair Culvert on Road 3 CX(s) Applied: B1.3 Date: 06/27/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office June 27, 2012 CX-008613: Categorical Exclusion Determination Replace Awning, Building 735-A CX(s) Applied: B1.3 Date: 06/27/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office June 26, 2012 CX-008618: Categorical Exclusion Determination Evaluation of Sorbent/Ion Exchangers for Radiochemical and Metal Separations CX(s) Applied: B3.6 Date: 06/26/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office June 26, 2012 CX-008617: Categorical Exclusion Determination Savannah River National Laboratory Building 735-13A Power Addition CX(s) Applied: B1.15

175

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

January 17, 2012 January 17, 2012 CX-007642: Categorical Exclusion Determination Parking Lot Construction North of Pad 717-14F CX(s) Applied: B1.15 Date: 01/17/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office January 4, 2012 CX-007646: Categorical Exclusion Determination Insulation removal work in F-Tank Farm CX(s) Applied: B1.3 Date: 01/04/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office January 4, 2012 CX-007645: Categorical Exclusion Determination Nonproliferation Technology Section - Nanomaterials Research CX(s) Applied: B3.6 Date: 01/04/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office December 29, 2011 CX-007650: Categorical Exclusion Determination Control Room Consolidation CX(s) Applied: B2.2

176

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

April 16, 2010 April 16, 2010 CX-002207: Categorical Exclusion Determination Thin Films for Whisker Growth CX(s) Applied: B3.6 Date: 04/16/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office April 16, 2010 CX-002206: Categorical Exclusion Determination Real-Waste Testing of Enhanced Chemical Cleaning for Sludge Heel Removal CX(s) Applied: B3.6 Date: 04/16/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office April 16, 2010 CX-002208: Categorical Exclusion Determination Monitor Instruments Mass Spectrometer at Aiken County Technology Laboratory CX(s) Applied: B3.6 Date: 04/16/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office

177

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

November 1, 2012 November 1, 2012 CX-009620: Categorical Exclusion Determination Next Generation Solvent (NGS) Real Waste Testing CX(s) Applied: B3.6 Date: 11/01/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office October 31, 2012 CX-009624: Categorical Exclusion Determination High Activity Waste Trailer (HAWT) Disposition CX(s) Applied: B3.1 Date: 10/31/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office October 31, 2012 CX-009623: Categorical Exclusion Determination Technetium Precipitation Batch Testing CX(s) Applied: B3.6 Date: 10/31/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office October 25, 2012 CX-009625: Categorical Exclusion Determination Preparation and Temperature-Time Settling Treatment of Rheology Samples

178

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

February 7, 2012 February 7, 2012 CX-007967: Categorical Exclusion Determination Electrochemical Fluorination in Molten Fluoride Salts CX(s) Applied: B3.6 Date: 02/07/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office February 7, 2012 CX-007966: Categorical Exclusion Determination Sampling of Legacy Material for Material, Control & Accountability (MC&A) Verification CX(s) Applied: B3.6 Date: 02/07/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office February 7, 2012 CX-007965: Categorical Exclusion Determination Grout Formulation & Variability Testing CX(s) Applied: B3.6 Date: 02/07/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office February 6, 2012 CX-007971: Categorical Exclusion Determination

179

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

November 7, 2011 November 7, 2011 CX-007671: Categorical Exclusion Determination Heat Exchanger Removal and Disposition CX(s) Applied: B6.1 Date: 11/07/2011 Location(s): South Carolina Offices(s): Savannah River Operations Office November 7, 2011 CX-007670: Categorical Exclusion Determination Maintenance Excavation of the B-07 Outfall Ditch CX(s) Applied: B1.3 Date: 11/07/2011 Location(s): South Carolina Offices(s): Savannah River Operations Office November 7, 2011 CX-007669: Categorical Exclusion Determination Vegetative Response to Metal Exposure in a Growing Media CX(s) Applied: B3.6 Date: 11/07/2011 Location(s): South Carolina Offices(s): Savannah River Operations Office October 27, 2011 CX-007672: Categorical Exclusion Determination Sampling of Nuclear Fuel Assembly CX(s) Applied: B3.6

180

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

February 24, 2011 February 24, 2011 CX-005504: Categorical Exclusion Determination Analytical Methods for Radiochemical Measurements CX(s) Applied: B3.6 Date: 02/24/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office February 24, 2011 CX-005503: Categorical Exclusion Determination Drain Line Replacement West of 735-A CX(s) Applied: B1.3 Date: 02/24/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office February 24, 2011 CX-005502: Categorical Exclusion Determination Implement Savannah River National Laboratory Defense Nuclear Facilities Safety Board 2004-2 Gap Closure Activity CX(s) Applied: B2.3 Date: 02/24/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

July 20, 2010 July 20, 2010 CX-003668: Categorical Exclusion Determination Subsurface Soils Exploration for Potential Pit Disassembly and Conversion Project Sandfilter Footprint CX(s) Applied: B3.1 Date: 07/20/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office July 7, 2010 CX-003670: Categorical Exclusion Determination Improvements to L Area Sidewalks CX(s) Applied: B1.3 Date: 07/07/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office July 7, 2010 CX-002984: Categorical Exclusion Determination Improvements to L Area Sidewalks CX(s) Applied: B1.3 Date: 07/07/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office June 25, 2010 CX-003671: Categorical Exclusion Determination

182

Experimental Verification of a Voltage Droop Control for Grid Integration of Offshore Wind Farms Using Multi-terminal HVDC  

Science Journals Connector (OSTI)

Abstract This paper presents an experimental verification of a voltage droop control for a multi-terminal HVDC system for the grid integration of offshore wind farms. The laboratory setup is composed by four voltage-source converter terminals which aim to emulate behavior of the future power grid in the North Sea, where Norway, Germany and the UK are interconnected together with an offshore wind farm. Two main scenarios have been performed to test the robustness of the droop-control strategy: variation in wind power, including changes in the parameters of the droop line, and the sudden disconnection of converter terminal during full wind production. In all performed cases, the implemented system was able to ensure that the voltage stays within its steady state limits and to reach a stable operation point.

Raymundo E. Torres-Olguin; Atle R. rdal; Hanne Stylen; Atsede G. Endegnanew; Kjell Ljkelsy; John Olav Tande

2014-01-01T23:59:59.000Z

183

Mobile Truck Stop Electrification Site Locator  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Mobile Truck Stop Electrification Site Locator Location Enter a city, postal code, or address Search Caution: The AFDC recommends that users verify that sites are open prior to...

184

Energy Department Launches Alternative Fueling Station Locator...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Launches Alternative Fueling Station Locator App Energy Department Launches Alternative Fueling Station Locator App November 7, 2013 - 11:16am Addthis As part of the Obama...

185

Persistent Uniform Resource Locators (PURLs) | Scientific and Technical  

Office of Scientific and Technical Information (OSTI)

Persistent Uniform Resource Locators (PURLs) Persistent Uniform Resource Locators (PURLs) Print page Print page Email page Email page PURLs (Persistent Uniform Resource Locators) are Web addresses that act as permanent identifiers in the face of a dynamic and changing Web infrastructure. Instead of resolving directly to Web resources, PURLs describe an intermediate location that allows the underlying Web addresses of resources to change over time without negatively affecting systems that depend on them. This capability provides continuity of references to network resources that may migrate from machine to machine for various reasons. Operation PURLs look just like URLs because they are valid URLs. A PURL has three parts: the protocol used to access the PURL resolver, the resolver IP address or domain, and a user-assigned name.

186

Realities of Chiller Plant Operation: Utility Impacts on Owner Operating  

NLE Websites -- All DOE Office Websites (Extended Search)

Realities of Chiller Plant Operation: Utility Impacts on Owner Operating Realities of Chiller Plant Operation: Utility Impacts on Owner Operating Costs and Societal Environmental Issues Speaker(s): Don Aumann Date: March 21, 2000 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Satkartar K. Kinney Don Aumann, a Senior Consultant from BKi in Oakland, will present an overview of two projects he completed for the electric utility industry. The first, a case study evaluation of a hybrid chiller plant in Jefferson City, Missouri, demonstrates the importance of carefully evaluating the impact of utility rate structures on plant operating costs. The building owner, another engineering consultant, and the local utility representatives were confused by the rates and missed an opportunity to cut chiller-plant operating costs by about 20%, totaling $15,000 per year. In

187

Intrinsically disordered C-terminal segments of voltage-activated potassium channels: a possible fishing rod-like mechanism for channel binding to scaffold proteins  

Science Journals Connector (OSTI)

Membrane-embedded voltage-activated potassium channels (Kv) bind intracellular scaffold proteins, such as the Post Synaptic Density 95 (PSD-95) protein, using a conserved PDZ-binding motif located at the channels' C-terminal tip. This interaction underlies ...

Elhanan Magidovich; Sarel J. Fleishman; Ofer Yifrach

2006-07-01T23:59:59.000Z

188

Lease Operations Environmental Guidance Document  

SciTech Connect

This report contains discussions in nine different areas as follows: (1) Good Lease Operating Practices; (2) Site Assessment and Sampling; (3) Spills/Accidents; (4) Containment and Disposal of Produced Waters; (5) Restoration of Hydrocarbon Impacted Soils; (6) Restoration of Salt Impacted Soils; (7) Pit Closures; (8) Identification, Removal and Disposal of Naturally Occurring Radioactive Materials (NORM); and (9) Site Closure and Construction Methods for Abandonment Wells/Locations. This report is primary directed towards the operation of oil and gas producing wells.

Bureau of Land Management

2001-02-14T23:59:59.000Z

189

Infrastructure and Operations | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Operations | National Nuclear Security Administration Operations | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Infrastructure and Operations Home > About Us > Our Operations > Infrastructure and Operations Infrastructure and Operations NNSA's missions require a secure production and laboratory infrastructure meeting immediate and long term needs. The Associate Administrator for

190

BOREAS Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Study Area Operations/Thompson Airport (NSA-Ops) Study Area Operations/Thompson Airport (NSA-Ops) NSA Operations (NSA-Ops) The Keewatin Air Hanger: site of BOREAS Ops 1994 Dr. Piers Sellers working in Ops, 1994 BOREAS "Air Force" The NASA C-130 The University of Wyoming King Air The NASA Helicopter The NRC Twin Otter The NCAR Electra The Ontario Chieftain Back to the BOREAS Photo Page Index Other Sites: NSA Photos ||NSA-BP Photos | NSA-Fen Photos | NSA-OA Photos | NSA-OBS Photos | NSA-OJP Photos | NSA-UBS Photos | NSA-YJP Photos | NSA-Ops Photos SSA Photos || SSA-Airport Photos | SSA-Fen Photos | SSA-Mix Photos | SSA-OA Photos | SSA-OBS Photos | SSA-OJP Photos | SSA-YA Photos | SSA-YJP Photos | SSA-Ops Photos | ORNL DAAC Home || ORNL Home || NASA || Privacy, Security, Notices || Data Citation || Rate Us || Help |

191

Major DOE Biofuels Project Locations  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Biofuels Biofuels Project Locations Pacific Ethanol (Boardman, OR) BlueFire Ethanol (Corona, CA) POET (Emmetsburg, IA) Lignol Innovations (Commerce City, CO) ICM (St. Joseph, MO) Abengoa (Hugoton, KS) DOE Joint Bioenergy Institute (Berkeley, CA) DOE Great Lakes Bioenergy Research Center (Madison, WI) DOE Bioenergy Science Center (Oak Ridge, TN) NewPage (Wisconsin Rapids, WI) Range Fuels (Soperton, GA) DSM Innovation Center (Parsippany, NJ) Novozymes (Davis, CA) Genencor (Palo Alto, CA) Verenium Corp (San Diego, CA) Dupont (Wilmington, DE) Mascoma (Lebanon, NH) Cargill Inc (Minneapolis, MN) Regional Partnerships South Dakota State University, Brookings, SD Cornell University, Ithaca, NY University of Tennessee, Knoxville, TN Oklahoma State University, Stillwater, OK Oregon State University, Corvallis, OR

192

Stratigraphic Profiles for Selected Hanford Site Seismometer Stations and Other Locations  

SciTech Connect

Stratigraphic profiles were constructed for eight selected Hanford Site seismometer stations, five Hanford Site facility reference locations, and seven regional three-component broadband seismometer stations. These profiles provide interpretations of the subsurface layers to support estimation of ground motions from past earthquakes, and the prediction of ground motions from future earthquakes. In most cases these profiles terminated at the top of the Wanapum Basalt, but at selected sites profiles were extended down to the top of the crystalline basement. The composite one-dimensional stratigraphic profiles were based primarily on previous interpretations from nearby boreholes, and in many cases the nearest deep borehole is located kilometers away.

Last, George V.

2014-02-01T23:59:59.000Z

193

Substation Operation  

Science Journals Connector (OSTI)

... THIS book is intended to help the workman to understand the principles of substation operation. It is a good attempt at giving somewhat advanced technical knowledge in such ... ." We are told not to use water to put out a fire at a substation before the station has been made completely " dead." The reason given for this ...

1925-08-01T23:59:59.000Z

194

Calculation and Use of Peaking Factors for Remote Terminal Emulation  

Science Journals Connector (OSTI)

An important goal of the remote terminal emulator-driven tests described here was obtaining a representative test workload. Reaching this goal depended on (i) imposing the test workload in a representative manner, (ii) using representative types of user ...

William A. Ward, Jr.; David Langan

2000-03-01T23:59:59.000Z

195

Calculation and Use of Peaking Factors for Remote Terminal Emulation  

Science Journals Connector (OSTI)

An important goal of the remote terminal emulator-driven tests described here was obtaining a representative test workload. Reaching this goal depended on (i) imposing the test workload in a representative man...

William A. Ward Jr.; David D. Langan

2000-01-01T23:59:59.000Z

196

A Power Optimized Display Memory Organization for Handheld User Terminals  

Science Journals Connector (OSTI)

Today's handheld devices become more and more multimedia capable. One subsystem of a multimedia terminal that accounts for a considerable amount of the total power consumption is the display unit. The backlight is the major culprit there. As new display ...

Lieven Hollevoet; Andy Dewilde; Kristof Denolf; Francky Catthoor; Filip Louagie

2004-02-01T23:59:59.000Z

197

California's LNG Terminals: The Promise of New Gas Supplies  

Energy.gov (U.S. Department of Energy (DOE))

Presentation covers California's LNG terminals and is given at the Federal Utility Partnership Working Group (FUPWG) Fall Meeting, held on November 28-29, 2007 in San Diego, California.

198

Transfer passenger needs at airports : human factors in terminal design  

E-Print Network (OSTI)

This thesis analyzes the needs of particular users of airport: transfer passengers. The object of this work has been to produce a set of design guidelines for terminals. these guidelines are framed upon a user-need survey ...

Brillembourg, Marie-Claire

1982-01-01T23:59:59.000Z

199

began at the PC4 facility, which is located  

NLE Websites -- All DOE Office Websites (Extended Search)

began at the PC4 facility, which is located at the Alabama Power Gaston began at the PC4 facility, which is located at the Alabama Power Gaston Power Plant Unit 5 (an 880-megawatt [MW] supercritical pulverized coal unit), when researchers used a monoethanolamine (MEA) solvent to capture CO 2 from a slipstream of flue gas from the plant. To date, the MEA solvent has exceeded the expected 90 percent CO 2 capture; the unit is now in steady operation, capturing approximately 10 tons

200

The Department's Fleet Vehicle Sustainability Initiatives at Selected Locations  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Department's Fleet Vehicle Department's Fleet Vehicle Sustainability Initiatives at Selected Locations DOE/IG-0896 October 2013 U.S. Department of Energy Office of Inspector General Office of Audits and Inspections Department of Energy Washington, DC 20585 October 24, 2013 MEMORANDUM FOR THE SECRETARY FROM: Gregory H. Friedman Inspector General SUBJECT: INFORMATION: Audit Report on "The Department's Fleet Vehicle Sustainability Initiatives at Selected Locations" BACKGROUND In Fiscal Year (FY) 2012, the Department of Energy's fleet consisted of 14,457 vehicles operated at an annual cost of approximately $131 million. Nearly 72 percent of the vehicles were leased through the General Services Administration (GSA), with the remaining Department-owned and

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

San Francisco Operations Office  

Office of Legacy Management (LM)

San Francisco Operations Office San Francisco Operations Office 1333 Broadway Oakland, California 94612 Dr. Joseph 0. Ward, Chief Radiological Health Section Department of Health Services 744 P Street Sacramento, California, 95814 SUBJECT: Certification Docket of Gilman Hall Dear Dr. Ward: The Department of Energy (DOE) has completed and reviewed the remedial ac- tions of Gilman Hall located at the University of California, Berkeley, California. Based on this review, DOE certifies that the condition of Gilman Hall is radiologically acceptable for restricted use under the con- trols of the University of California's State General License 1333-62 pro- vided that the University's Office of Environmental Health and Safety con- tinues to survey Gilman Hall and monitor whenever remodeling or renovation

202

User Operation Manual  

NLE Websites -- All DOE Office Websites (Extended Search)

SNS-NSSD-TOF-TD-0002 - R00 SNS-NSSD-TOF-TD-0002 - R00 1 SEQUOIA Operations Manual for Users G.E. Granroth SEQUOIA Lead Instrument Scientist A.I. Kolesnikov SEQUOIA Instrument Scientist L.M. DeBeer-Schmitt SEQUOIA Scientific Associate T.E. Sherline Sample Environment Scientist Revised - May 13, 2013 SNS-NSSD-TOF-TD-0002 - R00 2 Abstract The SEQUOIA Operations Manual for Users presents a description of the SEQUOIA spectrometer located at beamline 17 (BL17) of the Spallation Neutron Source (SNS). It is the intent of this manual to inform the user regarding the SEQUOIA spectrometer and available sample environment, to run experiments, to access and analyze the collected data, and to provide the user with other potentially useful information. The first section serves to describe the components of which the instrument is comprised.

203

NASA/Army/Bell XV-15 Tiltrotor Low-Noise Terminal Area Operations Flight Research Program  

Science Journals Connector (OSTI)

To evaluate the noise reduction potential for tiltrotor aircraft, a series of three XV-15 acoustic flight tests were conducted over a five-year period by a NASA/Army/Bell Helicopter team. Lower hemispherical noise characteristics for a wide range of ...

Edwards Bryan D.; Conner David A.; Decker William A.; Marcolini Michael A.; Klein Peter D.

2001-03-01T23:59:59.000Z

204

LNG Operations Risk Analyses: Evaluation and Comparison of Techniques and Results  

Science Journals Connector (OSTI)

This paper surveys the results and compares the techniques that have been employed in LNG risk analysis for three prospective sites of large scale LNG import terminals. Risks may arise from LNG vessel operations ...

Lloyd L. Philipson

1980-01-01T23:59:59.000Z

205

OPERATIONAL PERFORMANCES DEMONSTRATION OF POLYMER-CERAMIC EMBEDDED CAPACITORS FOR MMIC APPLICATIONS  

E-Print Network (OSTI)

coefficient and the thermal conductivity between the ceramic dielectric, the terminations, the solderOPERATIONAL PERFORMANCES DEMONSTRATION OF POLYMER- CERAMIC EMBEDDED CAPACITORS FOR MMIC candidates for dielectric materials applied for embedded passives are polymer- ceramic nanocomposites

Boyer, Edmond

206

Table 1. Personal Computers and Computer Terminals in Commercial Buildings,  

U.S. Energy Information Administration (EIA) Indexed Site

1 PC's and Computer Terminals 1 PC's and Computer Terminals Table 1. Personal Computers and Computer Terminals in Commercial Buildings, 1995 Buildings (thousand) Floorspace (million sq.ft.) Employees (thousand) PCs and Terminals (thousand) PCs and Terminals per Million Sq.Ft. PCs and Terminals per Thousand Employees All Buildings 4,579 58,772 75,262 43,003 732 571 Principal Building Activity Assembly 596 6,740 6,840 1,763 262 258 Education 309 7,740 9,495 8,046 1,039 847 Food Sales 137 642 652 206 321 316 Food Service 285 1,353 2,342 276 204 118 Health Care 105 2,333 4,483 2,549 1,092 569 Lodging 158 3,618 2,748 1,296 358 472 Mercantile and Service 1,289 12,728 13,049 4,021 316 308 Office 705 10,478 26,564 21,173 2,021 797

207

,"U.S. Refinery, Bulk Terminal, and Natural Gas Plant Stocks...  

U.S. Energy Information Administration (EIA) Indexed Site

Stocks at Refineries, Bulk Terminals, and Natural Gas Plants (Thousand Barrels)","U.S. Gasoline Blending Components Stocks at Refineries, Bulk Terminals, and Natural Gas Plants...

208

2014-03-06 Issuance: Test Procedures for Packaged Terminal Air...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3-06 Issuance: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps; Notice of Proposed Rulemaking 2014-03-06 Issuance: Test Procedures for...

209

NordhausGaddum bounds for locating domination  

Science Journals Connector (OSTI)

Abstract A dominating set S of graph G is called metric-locatingdominating if it is also locating, that is, if every vertex v is uniquely determined by its vector of distances to the vertices in S . If moreover, every vertex v not in S is also uniquely determined by the set of neighbors of v belonging to S , then it is said to be locatingdominating. Locating, metric-locatingdominating and locatingdominating sets of minimum cardinality are called ? -codes, ? -codes and ? -codes, respectively. A NordhausGaddum bound is a tight lower or upper bound on the sum or product of a parameter of a graph G and its complement G . In this paper, we present some NordhausGaddum bounds for the location number ? , the metric-locationdomination number ? and the locationdomination number ? . Moreover, in each case, the graph family attaining the corresponding bound is fully characterized.

C. Hernando; M. Mora; I.M. Pelayo

2014-01-01T23:59:59.000Z

210

Operation Poorman  

SciTech Connect

The objectives of Operation Poorman were to design and build a portable seismic system and to set up and use this system in a cold-weather environment. The equipment design uses current technology to achieve a low-power, lightweight system that is configured into three modules. The system was deployed in Alaska during wintertime, and the results provide a basis for specifying a mission-ready seismic verification system.

Pruvost, N.; Tsitouras, J.

1981-03-18T23:59:59.000Z

211

Inventory pre-positioning for humanitarian operations  

E-Print Network (OSTI)

This research examines the impact of inventory pre-positioning on humanitarian operations. The study identifies optimal locations for warehousing non-consumable inventories required for initial deployment of aid. These ...

Akkihal, Anup Roop

2006-01-01T23:59:59.000Z

212

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

December 17, 2009 December 17, 2009 CX-000810: Categorical Exclusion Determination Ceramic Synthesis and Gas Permeation Measurements in 735-11A CX(s) Applied: B3.6 Date: 12/17/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office December 17, 2009 CX-000809: Categorical Exclusion Determination Cut, Remove and Replace Off-Gas Exhaust Fan #2 and #3 foundation and Replace Air Monitor Fan #1 and #2 CX(s) Applied: B1.3 Date: 12/17/2009 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office December 17, 2009 CX-000808: Categorical Exclusion Determination Howard T. Ricketts Regional Biocontainment Laboratory 134 CX(s) Applied: B3.6 Date: 12/17/2009 Location(s): Aiken, South Carolina

213

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

May 16, 2011 May 16, 2011 CX-006405: Categorical Exclusion Determination 707-C Storm Drain Repairs CX(s) Applied: B1.3 Date: 05/16/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office May 13, 2011 CX-006406: Categorical Exclusion Determination Silver Chloride Injection at the F Area Hazardous Waste Management Facilities Barrier Wall CX(s) Applied: B6.9 Date: 05/13/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office May 12, 2011 CX-006407: Categorical Exclusion Determination Removal of Inactive Chromate Water Isolation Valves CRW-V-170 and CRW-V-175 and Installation of 3 Inch Blind Flanges for F-area New Hill CX(s) Applied: B1.3 Date: 05/12/2011 Location(s): Aiken, South Carolina

214

DHS/National Operations Center | National Nuclear Security Administrat...  

NLE Websites -- All DOE Office Websites (Extended Search)

Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Countering Nuclear Terrorism About Our History Who We Are Our Leadership Our Locations Budget Our Operations...

215

Location Based Security for Smart Grid Applications  

Science Journals Connector (OSTI)

Abstract Smart Grid (SG) promises efficient, sustainable, green and reliable electrical delivery by combining the existing electrical distribution network assets with modern information and communications technologies (ICT) in order to transfer information and energy in both directions. Introduction of these intelligent devices will help the grid monitor, protect, and automatically optimise the operation of interconnected elements, in addition to interaction between energy suppliers and consumers. However, this exposes the future grid to new security challenges and risks. In this paper, a framework for protecting Smart Grid applications using geographic location of the devices connected to it is proposed. With this framework, each device on the grid adds an extra layer of security. The proposed scheme is not application or device specific which means it can be implemented on any communication node on the grid. The scheme uses an algebraic code based cryptosystems known as GPT (Gabidulin -Paramonov-Trejtakov), which provides a very strong protection while utilising the smallest key size as compared to other cryptosystems based on algebraic codes. As with other code based cryptosystems, the proposed security framework protects grid information against cyber threats as well as against channel impairments in the form of error protection codes.

Eraj Khan; Bamidele Adebisi; Bahram Honary

2013-01-01T23:59:59.000Z

216

SAPLE: Sandia Advanced Personnel Locator Engine.  

SciTech Connect

We present the Sandia Advanced Personnel Locator Engine (SAPLE) web application, a directory search application for use by Sandia National Laboratories personnel. SAPLE's purpose is to return Sandia personnel 'results' as a function of user search queries, with its mission to make it easier and faster to find people at Sandia. To accomplish this, SAPLE breaks from more traditional directory application approaches by aiming to return the correct set of results while placing minimal constraints on the user's query. Two key features form the core of SAPLE: advanced search query interpretation and inexact string matching. SAPLE's query interpretation permits the user to perform compound queries when typing into a single search field; where able, SAPLE infers the type of field that the user intends to search on based on the value of the search term. SAPLE's inexact string matching feature yields a high-quality ranking of personnel search results even when there are no exact matches to the user's query. This paper explores these two key features, describing in detail the architecture and operation of SAPLE. Finally, an extensive analysis on logged search query data taken from an 11-week sample period is presented.

Procopio, Michael J.

2010-04-01T23:59:59.000Z

217

Homodyne impulse radar hidden object locator  

DOE Patents (OSTI)

An electromagnetic detector is designed to locate an object hidden behind a separator or a cavity within a solid object. The detector includes a PRF generator for generating 2 MHz pulses, a homodyne oscillator for generating a 2 kHz square wave, and for modulating the pulses from the PRF generator. A transmit antenna transmits the modulated pulses through the separator, and a receive antenna receives the signals reflected off the object. The receiver path of the detector includes a sample and hold circuit, an AC coupled amplifier which filters out DC bias level shifts in the sample and hold circuit, and a rectifier circuit connected to the homodyne oscillator and to the AC coupled amplifier, for synchronously rectifying the modulated pulses transmitted over the transmit antenna. The homodyne oscillator modulates the signal from the PRF generator with a continuous wave (CW) signal, and the AC coupled amplifier operates with a passband centered on that CW signal. The present detector can be used in several applications, including the detection of metallic and non-metallic objects, such as pipes, studs, joists, nails, rebars, conduits and electrical wiring, behind wood wall, ceiling, plywood, particle board, dense hardwood, masonry and cement structure. The detector is portable, light weight, simple to use, inexpensive, and has a low power emission which facilitates the compliance with Part 15 of the FCC rules.

McEwan, Thomas E. (Livermore, CA)

1996-01-01T23:59:59.000Z

218

Emergency Operations Training Academy | National Nuclear Security  

National Nuclear Security Administration (NNSA)

Operations Training Academy | National Nuclear Security Operations Training Academy | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Emergency Operations Training Academy Home > About Us > Our Programs > Emergency Response > Training > Emergency Operations Training Academy Emergency Operations Training Academy Rotating image showing pictures of Classroom, Online and Hands on trainings

219

STANDARD OPERATING PROCEDURE DIMETHYL SULFOXIDE (DMSO)  

E-Print Network (OSTI)

be handled as hazardous waste. 8. Decontamination: Specific instructions: Wash items/surfaces with light12.1 STANDARD OPERATING PROCEDURE for DIMETHYL SULFOXIDE (DMSO) Location(s): ___________________________________________________ Chemical(s): Dimethyl Sulfoxide (DMSO) Specific Hazards: Combustible liquid, transport across skin barrier

Pawlowski, Wojtek

220

Morphisms of ANN and the Computation of Least Fixed Points of Semantic Operators  

E-Print Network (OSTI)

consequence operator TP can be computed by the colimit of a family of neural networks determined by P. 1 is the computation by ANN of the operators P , such as the immediate consequence operator TP , de- termined the structure of ANN, and one should expect iso- morphic ANN to compute the same function. (Alternatively, one

Seda, Anthony Karel

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Welcome to Berkeley! Locations and Orientation  

E-Print Network (OSTI)

Golden Gate Bridge · Take SF's bus, MUNI (40-50 min from Transbay Bus Terminal) · Ground-breaking project · Worth walking on · Great in photos *Golden Gate Bridge is far from Golden Gate Park *Visit Gate Bridge, ferry back ($30-70) · Motor karts are also available · Safety first! Helmet! *Cross over

Jacobs, Lucia

222

New Location for Solar Decathlon 2011 Announced | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Location for Solar Decathlon 2011 Announced Location for Solar Decathlon 2011 Announced New Location for Solar Decathlon 2011 Announced February 23, 2011 - 5:00pm Addthis Ginny Simmons Ginny Simmons Former Managing Editor for Energy.gov, Office of Public Affairs What are the key facts? Sept. 23-Oct. 2, 2011 The National Mall -- West Potomac Park in Washington, D.C. This year's U.S. Department of Energy Solar Decathlon competition will be held at the National Mall's West Potomac Park. Specifically, between the Franklin Delano Roosevelt Memorial and the Potomac River. The Solar Decathlon challenges 20 teams to design, build and operate solar-powered houses that are cost-effective, energy-efficient and attractive. The first Solar Decathlon was held in 2002. Since then, they've been held biennially in 2005, 2007, 2009 and this year. The 2011 event will be held

223

LOCATION OF THUNDERSTORMS BY RADIO METHODS  

Science Journals Connector (OSTI)

... systems are well known, and the exact location can be determined when the line or substation is afterwards inspected. Thus power supply system statistics provide reliable evidence of the location ...

1943-03-06T23:59:59.000Z

224

Determining Mountaintop Mining Locations in West Virginia Using Elevation Datasets  

E-Print Network (OSTI)

Determining Mountaintop Mining Locations in West Virginia Using Elevation Datasets Danny Rowland Haskell Indian Nations University Image from: http://www.colorado.edu/geography/cartpro/cartography2/spring2006/syphers.../projects/westvirginia/whatis.htm Image from: http://washingtonindependent.com/49008/congress-takes-on-mountaintop-mining Mountaintop Mining Operation 2 Elevation datasets: NED & SRTM West Virginia NED SRTM Elevation Change Over ~30 Year Period 20021970s SRTM Subtracted from...

Rowland, Danny

2009-11-18T23:59:59.000Z

225

Retrofit design of a boil-off gas handling process in liquefied natural gas receiving terminals  

Science Journals Connector (OSTI)

Generation of Boil-off gas (BOG) in liquefied natural gas (LNG) receiving terminals considerably affects operating costs and the safety of the facility. For the above reasons, a proper BOG handling process is a major determinant in the design of a LNG receiving terminal. This study proposes the concept of a retrofit design for a BOG the handling process using a fundamental analysis. A base design was determined for a minimum send-out case in which the BOG handling becomes the most difficult. In the proposed design, the cryogenic energy of the LNG stream is used to cool other streams inside the process. It leads to a reduction in the operating costs of the compressors in the BOG handling process. Design variables of the retrofit design were optimized with non-linear programming to maximize profitability. Optimization results were compared with the base design to show the effect of the proposed design. The proposed design provides a 22.7% energy saving ratio and a 0.176 year payback period.

Chansaem Park; Kiwook Song; Sangho Lee; Youngsub Lim; Chonghun Han

2012-01-01T23:59:59.000Z

226

Time-Domain Absorbing Boundary Terminations for Waveguide Ports Based on State-Space Models  

E-Print Network (OSTI)

Absorbing boundary conditions for waveguide ports in time domain are important elements of transient approaches to treat RF structures. A successful way to implement these termination conditions is the decomposition of the transient fields in the absorbing plane in terms of modal field patterns. The absorbing condition is then accomplished by transferring the wave impedances (or admittances) of the modes to time domain, which leads to convolution operations involving Bessel functions and integrals of Bessel functions. This paper presents a new alternative approach: the convolution operations are approximated by appropriate state-space models whose system responses can be conveniently computed by standard integration schemes. These schemes are indispensable for transient simulations anyhow. Sufficiently far away from the cutoff frequency, a wideband match is achieved.

Flisgen, T; van Rienen, U

2014-01-01T23:59:59.000Z

227

Analysis of the AirTouch automatic vehicle location system's ability to locate moving vehicles  

E-Print Network (OSTI)

Automatic vehicle location systems are becoming more prevalent in diverse transportation applications. Their ability to locate vehicles can assist in locating emergency and public transit vehicles for better real-time dispatching as well...

Henry, Tracy Lynn

2012-06-07T23:59:59.000Z

228

Function of transcription termination factor .rho. in a model transcription system using synthetic DNA as template  

Science Journals Connector (OSTI)

Function of transcription termination factor .rho. in a model transcription system using synthetic DNA as template ...

Katsuya Shigesada; Mutsuo Imai

1982-11-01T23:59:59.000Z

229

Alternative Fueling Station Locator | Open Energy Information  

Open Energy Info (EERE)

Alternative Fueling Station Locator Alternative Fueling Station Locator Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Alternative Fueling Station Locator Agency/Company /Organization: United States Department of Energy Partner: National Renewable Energy Laboratory Sector: Energy Focus Area: Fuels & Efficiency, Transportation Phase: Evaluate Options, Prepare a Plan Topics: Datasets Resource Type: Online calculator User Interface: Website Website: www.afdc.energy.gov/afdc/locator/stations/ Web Application Link: www.afdc.energy.gov/afdc/locator/stations/ Cost: Free OpenEI Keyword(s): Featured References: National Renewable Energy Laboratory Advanced Vehicles and Fuels Research: Data and Resources[1] Logo: Alternative Fueling Station Locator The alternative fuel station locator uses an address based search to find

230

A study on the control method of single duct VAV terminal unit through the determination of proper minimum air flow  

Science Journals Connector (OSTI)

Abstract The objective of this study was proposed a control method for the minimum air flow rate of a VAV terminal unit at an office building. The minimum air flow rate of the VAV terminal unit is the key factor affecting the thermal comfort, indoor air quality (IAQ), stratification and energy consumption, depending on the operating mode of the VAV system. Therefore, selecting the proper minimum air flow is very important. In this study, an algorithm was proposed considering the IAQ and stratification. The vertical air temperature was analyzed to find the supply air temperature that did not cause stratification. The integrated control algorithm with an air flow increase model in the VAV terminal unit and outdoor air intake rate increase model in the AHU was developed by comparing the energy consumption. Finally, the existing and proposed control algorithms were compared through a simulation. The proposed method was found to be more effective than the existing control method. The proposed VAV terminal unit control method satisfies all the conditions of indoor thermal comfort, IAQ and stratification issue. As a result of the energy comparison with the existing control method, the method satisfies not only the indoor thermal comfort, IAQ and stratification issue, but also reduces the energy consumption.

Su-Hyun Kang; Hyo-Jun Kim; Young-Hum Cho

2014-01-01T23:59:59.000Z

231

Tri-Met's Experience With Automatic Passenger Counter and Automatic Vehicle Location Systems  

E-Print Network (OSTI)

Tri-Met's Experience With Automatic Passenger Counter and Automatic Vehicle Location Systems James includes Automatic Vehicle Location (AVL) using a satellite-based global positioning system (GPS); · Voice for temporary data storage, a vehicle control head displaying schedule adherence to operators, detection

Bertini, Robert L.

232

A valiant little terminal: A VLT user's manual  

SciTech Connect

VLT came to be used at SLAC (Stanford Linear Accelerator Center), because SLAC wanted to assess the Amiga's usefulness as a color graphics terminal and T{sub E}X workstation. Before the project could really begin, the people at SLAC needed a terminal emulator which could successfully talk to the IBM 3081 (now the IBM ES9000-580) and all the VAXes on the site. Moreover, it had to compete in quality with the Ann Arbor Ambassador GXL terminals which were already in use at the laboratory. Unfortunately, at the time there was no commercial program which fit the bill. Luckily, Willy Langeveld had been independently hacking up a public domain VT100 emulator written by Dave Wecker et al. and the result, VLT, suited SLAC's purpose. Over the years, as the program was debugged and rewritten, the original code disappeared, so that now, in the present version of VLT, none of the original VT100 code remains.

Weinstein, A.

1992-08-01T23:59:59.000Z

233

Probing the nuclear energy functional at band termination  

Science Journals Connector (OSTI)

A systematic study of terminating states in the A~50 mass region using the self-consistent Skyrme-Hartree-Fock model is presented. The objective of this study is to demonstrate that the terminating states, due to their intrinsic simplicity, offer unique and so far unexplored opportunities to study different aspects of the effective NN interaction or nuclear local energy density functional. In particular, we show that the agreement of the calculations to the data depends on the spin fields and the spin-orbit term which, in turn, allows us to constrain the appropriate Landau parameters and the strength of the spin-orbit potential. The present study reveals that the structure and energy of terminating states can be used as a tool to differentiate among the many Skyrme force parametrizations.

Honorata Zdu?czuk; Wojciech Satu?a; Ramon A. Wyss

2005-02-09T23:59:59.000Z

234

New San Antonio Airport Terminal Generating Clean Power | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

San Antonio Airport Terminal Generating Clean Power San Antonio Airport Terminal Generating Clean Power New San Antonio Airport Terminal Generating Clean Power January 27, 2011 - 2:03pm Addthis The new photovoltaic system at the San Antonio International Airport. The new photovoltaic system at the San Antonio International Airport. Todd G. Allen Project Officer, Golden Field Office What are the key facts? The City of San Antonio's EECBG proram staff awarded a block grant for a solar photovoltaic (PV) system at the airport, designed and built the project, and complied with all local and federal regulations... all in seven months. In early 2010, the City of San Antonio's Energy Efficiency and Conservation Block Grant (EECBG) program staff quickly realized a golden opportunity lay right at their fingertips. The opening of the new San

235

Integrating VAV zone requirements with supply fan operation. [Variable Air Volume  

SciTech Connect

The use of communicating direct digital controls (DDC) with distributed intelligence offers new opportunities for energy conservation while maintaining occupant comfort in commercial buildings. Integrating control within a single DDC panel improves performance. Integrating control by communications between multiple controllers can further enhance system operation. One example is a DDC static pressure reset strategy for supply fan operation in variable air volume (VAV) supply air distribution systems. This strategy integrates the requirements of the VAV terminal units serving the building zones to minimize fan energy use. This article describes terminal unit operation, supply fan control, concurrent polling, operational data and power savings.

Warren, M.L. (ASI Controls, San Ramon, CA (United States)); Norford, L.K. (Massachusetts Inst. of Tech., Cambridge (United States))

1993-04-01T23:59:59.000Z

236

Major DOE Biofuels Project Locations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Major DOE Biofuels Project Locations Major DOE Biofuels Project Locations Major DOE Biofuels Project Locations More Documents & Publications Major DOE Biofuels Project Locations...

237

Role of chemical termination in edge contact to graphene  

SciTech Connect

Edge contacts to graphene can offer excellent contact properties. Role of different chemical terminations is examined by using ab initio density functional theory and quantum transport simulations. It is found that edge termination by group VI elements O and S offers considerably lower contact resistance compared to H and group VII element F. The results can be understood by significantly larger binding energy and shorter binding distance between the metal contact and these group VI elements, which results in considerably lower interface potential barrier and larger transmission. The qualitative conclusion applies to a variety of contact metal materials.

Gao, Qun; Guo, Jing, E-mail: guoj@ufl.edu [Department of Electrical and Computer Engineering, University of Florida, Gainesville, Florida 32611 (United States)

2014-05-01T23:59:59.000Z

238

Base drive circuit for a four-terminal power Darlington  

DOE Patents (OSTI)

A high power switching circuit which utilizes a four-terminal Darlington transistor block to improve switching speed, particularly in rapid turn-off. Two independent reverse drive currents are utilized during turn off in order to expel the minority carriers of the Darlington pair at their own charge sweep-out rate. The reverse drive current may be provided by a current transformer, the secondary of which is tapped to the base terminal of the power stage of the Darlington block. In one application, the switching circuit is used in each power switching element in a chopper-inverter drive of an electric vehicle propulsion system.

Lee, Fred C. (Blacksburg, VA); Carter, Roy A. (Salem, VA)

1983-01-01T23:59:59.000Z

239

Static power reduction for midpoint-terminated busses  

DOE Patents (OSTI)

A memory system is disclosed which is comprised of a memory controller and addressable memory devices such as DRAMs. The invention provides a programmable register to control the high vs. low drive state of each bit of a memory system address and control bus during periods of bus inactivity. In this way, termination voltage supply current can be minimized, while permitting selected bus bits to be driven to a required state. This minimizes termination power dissipation while not affecting memory system performance. The technique can be extended to work for other high-speed busses as well.

Coteus, Paul W. (Yorktown Heights, NY); Takken, Todd (Brewster, NY)

2011-01-18T23:59:59.000Z

240

Microsoft Word - CX-RossTransformerOilTerminalUpgradeFY12_WEB.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4, 2012 4, 2012 REPLY TO ATTN OF: KEP-4 SUBJECT: Environmental Clearance Memorandum Brett Sherer Project Manager - KEP-4 Proposed Action: Ross Transformer Oil Terminal Upgrade Work Order #: 00298659 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6, Additions or modifications to electric power transmission facilities Location: Ross Complex, Township 2 North, Range 1 East, Section 14 of Clark County, Washington Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to install four new horizontal, double walled, 20,000 gallon insulating oil storage tanks at BPA's Ross Complex. In addition, BPA would install a railcar oil pumping and transfer system as well as a truck oil transfer pad. Both the

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Locating-total domination in graphs  

Science Journals Connector (OSTI)

In this paper, we continue the study of locating-total domination in graphs. A set S of vertices in a graph G is a total dominating set in G if every vertex of G is adjacent to a vertex in S . We consider total dominating sets S which have the additional property that distinct vertices in V ( G ) ? S are totally dominated by distinct subsets of the total dominating set. Such a set S is called a locating-total dominating set in G , and the locating-total domination number of G is the minimum cardinality of a locating-total dominating set in G . We obtain new lower and upper bounds on the locating-total domination number of a graph. Interpolation results are established, and the locating-total domination number in special families of graphs, including cubic graphs and grid graphs, is investigated.

Michael A. Henning; Nader Jafari Rad

2012-01-01T23:59:59.000Z

242

Community Detection from Location-Tagged Networks  

E-Print Network (OSTI)

Many real world systems or web services can be represented as a network such as social networks and transportation networks. In the past decade, many algorithms have been developed to detect the communities in a network using connections between nodes. However in many real world networks, the locations of nodes have great influence on the community structure. For example, in a social network, more connections are established between geographically proximate users. The impact of locations on community has not been fully investigated by the research literature. In this paper, we propose a community detection method which takes locations of nodes into consideration. The goal is to detect communities with both geographic proximity and network closeness. We analyze the distribution of the distances between connected and unconnected nodes to measure the influence of location on the network structure on two real location-tagged social networks. We propose a method to determine if a location-based community detection...

Liu, Zhi

2015-01-01T23:59:59.000Z

243

GARS Operations Newsletter G  

NLE Websites -- All DOE Office Websites (Extended Search)

1 1 GARS Operations Newsletter G l o b a l a n d R e g i o n a l S o l u t i o n s D i r e c t o r a t e V OLUME 2 , ISSUE 1 Safety Solutions and Pollution Prevention Proposals Congratulations to Barbara Roland of the Nonproliferation and National Security Dept.! Barbara's Safety Solution proposal has been funded. To improve personnel safety in Building 197 during emergency situations, she suggested that pathway markers be positioned on the hallway walls to help locate the Indoor Assembly Areas and Evacuation routes. Light mo- tion detectors for "common areas" in several of our buildings was also funded. This idea sprung from a suggestion received during our Director- ate Safety Stand Down in 2009. This will improve safety and conserve energy too. Remember to send us your suggestions for next year!

244

Location-dependent communications using quantum entanglement  

SciTech Connect

The ability to unconditionally verify the location of a communication receiver would lead to a wide range of new security paradigms. However, it is known that unconditional location verification in classical communication systems is impossible. In this work we show how unconditional location verification can be achieved with the use of quantum communication channels. Our verification remains unconditional irrespective of the number of receivers, computational capacity, or any other physical resource held by an adversary. Quantum location verification represents an application of quantum entanglement that delivers a feat not possible in the classical-only channel. It gives us the ability to deliver real-time communications viable only at specified geographical coordinates.

Malaney, Robert A. [School of Electrical Engineering and Telecommunications, University of New South Wales, New South Wales 2052 (Australia)

2010-04-15T23:59:59.000Z

245

Implementing Rational Surface Locations Measured From Thomson...  

NLE Websites -- All DOE Office Websites (Extended Search)

Rational Surface Locations Measured From Thomson Scattering Into MSTfit by Curtis A. Johnson Senior Thesis (Physics) at the University of Wisconsin-Madison 2014 i Abstract...

246

Stochastic p-Robust Location Problems  

E-Print Network (OSTI)

We present p-robust models based on two classical facility location problems, ... University, Department of Industrial Engineering and Management Sciences,...

2004-08-03T23:59:59.000Z

247

Regenerator Location Problem in Flexible Optical Networks  

E-Print Network (OSTI)

Nov 22, 2014 ... Abstract: In this study we introduce the regenerator location problem in flexible optical networks (RLP-FON). With a given traffic demand,...

BARIS YILDIZ

2014-11-22T23:59:59.000Z

248

Procurement Information by Location | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Procurement Information by Location Procurement Information by Location Procurement Information by Location As part of our Small Business Opportunity Tool, we are offering information about historical procurement by location. Find historical procurement data by state - check out the list of states below, and click on the state's name to learn more about their current programs and past procurement needs. Click on the state to learn more about our current procurement activity: California Colorado District of Columbia Georgia Idaho Illinois Iowa Louisana Maryland Missouri Nevada New Jersey New Mexico New York Ohio Oklahoma Oregon Pennsylvania South Carolina Tennessee Texas Virginia West Virginia Washington Wyoming

249

Optimization Online - Public Facility Location Using Dispersion ...  

E-Print Network (OSTI)

Jan 27, 2013 ... Our results show close collaboration with the p-median solution when decision makers restrict location to demand points, and use parameter...

Rajan Batta

2013-01-27T23:59:59.000Z

250

CMS FNAL Remote Operations Center  

NLE Websites -- All DOE Office Websites (Extended Search)

LHC@FNAL Remote Operations Center (ROC) at Fermilab is located on the first floor of Wilson Hall. From the ROC, shifters perform real-time monitoring of the data recorded by the CMS Experiment. LHC@FNAL Remote Operations Center (ROC) at Fermilab is located on the first floor of Wilson Hall. From the ROC, shifters perform real-time monitoring of the data recorded by the CMS Experiment. ROC WBM / WBM Twiki FNAL ELog Mailing List Agendas / ROC Presentations & Notes WBM Publications Runs CVS SiTracker / MTCC AEM / AEM help Screen Snapshot Service FAQ Accounts & Nodes New User Instructions WebCams CMS Workbook Directories / Glossaries Photos Vidyo / EVO Google / Wikipedia LHC@FNAL Computing Console Map Documents Mailing List One East Mtg Schedule rocshare Telephones To Do List Video Conferencing CMS Shifter CSC DAQ DataOps DQM / FNAL ROC ECAL Event Display HCAL Pixel Trigger Global Run Calendar CMS Live Contact List DAQ Status DAS

251

LM137/LM337 3-Terminal Adjustable Negative Regulators  

E-Print Network (OSTI)

LM137/LM337 3-Terminal Adjustable Negative Regulators General Description The LM137/LM337 design has been opti- mized for excellent regulation and low thermal transients. Further, the LM137 virtually blowout-proof against overloads. The LM137/LM337 serve a wide variety of applications in- cluding

Ravikumar, B.

252

LM137/LM337 3-Terminal Adjustable Negative Regulators  

E-Print Network (OSTI)

LM137/LM337 3-Terminal Adjustable Negative Regulators General Description The LM137/LM337. The circuit design has been opti- mized for excellent regulation and low thermal transients. Further, the LM them virtually blowout-proof against overloads. The LM137/LM337 serve a wide variety of applications in

Berns, Hans-Gerd

253

Truck scheduling at zero-inventory cross docking terminals  

Science Journals Connector (OSTI)

Handling freight at cross docking terminals constitutes a complex planning task which comprises several executive steps as shipments delivered by inbound trucks are to be unloaded, sorted according to their designated destinations, moved across the dock ... Keywords: Cross docking, Dynamic programming, Food industry, Logistics, Truck scheduling

Nils Boysen

2010-01-01T23:59:59.000Z

254

Propionic-Acid-Terminated Silicon Nanoparticles: Synthesis and Optical Characterization  

E-Print Network (OSTI)

producing water-dispersible, propionic-acid-terminated particles. From transmission electron microscope (TEM oxidation of the nanocrystals. The silicon nanocrystals could be transferred into water or methanol in acrylic acid, water, and methanol and showed essentially the same optical properties in all three solvents

Swihart, Mark T.

255

Highly Z-Selective Metathesis Homocoupling of Terminal Olefins  

E-Print Network (OSTI)

Mo and W MonoAryloxide-Pyrrolide (MAP) olefin metathesis catalysts can couple terminal olefins to give as high as >98% Z-products in moderate to high yields with as little as 0.2% catalyst. Results are reported for 1-hexene, ...

Jiang, Annie J.

256

Department of Mechanical Engineering Spring 2012 Synthetic Cable Termination  

E-Print Network (OSTI)

PENNSTATE Department of Mechanical Engineering Spring 2012 Synthetic Cable Termination Overview NAVAIR is attempting to replace their existing metallic purchase cable with a new, synthetic cable. The synthetic cable is currently not able to be tensile tested because there is no way for the ends

Demirel, Melik C.

257

Risks to VDT operators  

Science Journals Connector (OSTI)

... on the surface of video-display-terminal (VDT) screens. He attributes these activities to radon progeny deposition due to high levels of electrostatic charge on the screen, and suggests ... the submicron fraction comprises only about 4 per cent.

WALTER C. WEDBERG

1991-07-18T23:59:59.000Z

258

Columbia River: Terminal fisheries research project. 1994 Annual report  

SciTech Connect

Columbia River terminal fisheries have been conducted in Youngs Bay, Oregon, since the early 1960`s targeting coho salmon produced at the state facility on the North Fork Klaskanine River. In 1977 the Clatsop County Economic Development Council`s (CEDC) Fisheries Project began augmenting the Oregon Department of Fish and Wildlife production efforts. Together ODFW and CEDC smolt releases totaled 5,060,000 coho and 411,300 spring chinook in 1993 with most of the releases from the net pen acclimation program. During 1980-82 fall commercial terminal fisheries were conducted adjacent to the mouth of Big Creek in Oregon. All past terminal fisheries were successful in harvesting surplus hatchery fish with minimal impact on nonlocal weak stocks. In 1993 the Northwest Power Planning Council recommended in its` Strategy for Salmon that terminal fishing sites be identified and developed. The Council called on the Bonneville Power Administration to fund a 10-year study to investigate the feasibility of creating and expanding terminal known stock fisheries in the Columbia River Basin. The findings of the initial year of the study are included in this report. The geographic area considered for study extends from Bonneville Dam to the river mouth. The initial year`s work is the beginning of a 2-year research stage to investigate potential sites, salmon stocks, and methodologies; a second 3-year stage will focus on expansion in Youngs Bay and experimental releases into sites with greatest potential; and a final 5-year phase establishing programs at full capacity at all acceptable sites. After ranking all possible sites using five harvest and five rearing criteria, four sites in Oregon (Tongue Point, Blind Slough, Clifton Channel and Wallace Slough) and three in Washington (Deep River, Steamboat Slough and Cathlamet Channel) were chosen for study.

Hirose, P.; Miller, M.; Hill, J.

1996-12-01T23:59:59.000Z

259

FINDING OF NO SIGNIFICANT IMPACT ENVIRONMENTAL ASSESSMENT FOR THE FUTURE LOCATION  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

30, 2002 DOEIEA-1438 . 30, 2002 DOEIEA-1438 . FINDING OF NO SIGNIFICANT IMPACT ENVIRONMENTAL ASSESSMENT FOR THE FUTURE LOCATION OF HEAT SOURCEfRADIOISOTOPE POWER SYSTEM: ASSEMBLY AND TEST OPERATIONS CURRENTLY LOCATED AT THE MOUND SITE AGENCY: U.S. Department of Energy ACTION: Finding of No Significant Impact SUMMARY: The U.S. Department of Energy (the Department) has completed an Environmental Assessment for the Future Location of the Reat SourcelRadioisotope Power System Assembly and Test Operations Currently Located at the Mound Site. Based on the analysis in the environmental assessment, the Department has determined that the proposed action, the relocation of the Department's heat source and radioisotope power system operations, does not constitute' a major Federal action significantly affecting the

260

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

October 3, 2011 October 3, 2011 CX-006944: Categorical Exclusion Determination Remove Insulation from High Point Flush Pump Drain Valve CX(s) Applied: B1.3 Date: 10/03/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, National Energy Technology Laboratory September 29, 2011 CX-006946: Categorical Exclusion Determination Operation of Accredited Industrial Hygiene (IH) Laboratory in Building 772-F, Revision 1 CX(s) Applied: B3.6 Date: 09/29/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, National Energy Technology Laboratory September 28, 2011 CX-006955: Categorical Exclusion Determination Repair Radiological Fixative Coatings in F Tank Farm CX(s) Applied: B1.3 Date: 09/28/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Sandia Site Office

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

RECYCLING PROGRAM TYPE LOCATION ALLOWED NOT ALLOWED  

E-Print Network (OSTI)

RECYCLING PROGRAM TYPE LOCATION ALLOWED NOT ALLOWED Batteries, toner, ink cartridges & cell phones and recycling is an important part of that effort. Below is a guide to on-campus recycling at RSMAS: Visit http://www.rsmas.miami.edu/msgso/ for map of recycling bin locations. NOTE: This is not an exhaustive list. If unauthorized items are found

Miami, University of

262

Property:UtilityLocation | Open Energy Information  

Open Energy Info (EERE)

UtilityLocation UtilityLocation Jump to: navigation, search Property Name UtilityLocation Property Type Boolean Description Indicates this is the "mailing" location of the Utility. Usually is Yes if the information from EIA Form 861 File1_a is on the page. Pages using the property "UtilityLocation" Showing 25 pages using this property. (previous 25) (next 25) 3 3 Phases Energy Services + true + 4 4-County Electric Power Assn + true + A A & N Electric Coop (Virginia) + true + AEP Generating Company + true + AEP Texas Central Company + true + AEP Texas North Company + true + AES Eastern Energy LP + true + AGC Division of APG Inc + true + AP Holdings LLC + true + APN Starfirst, L.P. + true + APNA Energy + true + Accent Energy Holdings, LLC + true +

263

Property:Event/Location | Open Energy Information  

Open Energy Info (EERE)

Location Location Jump to: navigation, search Property Name Event/Location Property Type String Description The location in which an event will occur. Examples: 'Golden, Colorado' or 'Prestigious Hotel: 11 Rue Leroy, Paris, France'. Pages using the property "Event/Location" Showing 25 pages using this property. (previous 25) (next 25) 1 11th Annual Workshop on Greenhouse Gas Emission Trading + Paris, France + 11th Annual Workshop on Greenhouse Gas Emission Trading Day 2 + Paris, France + 15th International Business Forum: Low Carbon High Growth - Business Models for a Changing Climate + Pretoria, South Africa + 18th Africa Partnership Forum + Paris, France + 2 2012 Bonn Climate Change Conference + Bonn, Germany + 7 7th Asia Clean Energy Forum + Manila, Philippines +

264

Formal Specification of Operating System Operations  

E-Print Network (OSTI)

Formal Specification of Operating System Operations Dan Zhou Department of Computer Science.black@nist.gov This paper describes the development of a formal specification for a secure operating system architecture operations. We also provide a uniform environment for system commands that change the security state

Black, Paul E.

265

A flexible location management scheme for mobile computing  

E-Print Network (OSTI)

&rib?ted Database Manage- ment. System (DDBMS) is the clevelopirient, p)atlo& m, and we are using Proc"'C with el&lbeddi (I SQL. Though t, he two Viv&IX workstation& are accessing thi. san&e ORA- CLE server at SparcServer l000, they are using indcpen&leut dat, a..., objects. In fact, , these data objects can he distributed among s&vcral network hosts usiug OKACLE SQL NET ivithoiit any modihcation of the codes foi thc location operations. The Chent (UltraSparc: dasher) Client (UltraSparc: dancer) ORACLE Server...

Zhang, Ying

1996-01-01T23:59:59.000Z

266

WEBtop (Operating Systems on Web)  

Science Journals Connector (OSTI)

WebOS (Web based operating system) is a new form of Operating Systems. You can use your desktop as a virtual desktop on the web accessible via a browser with multiple integrated built?in applications that allow the user to easily manage and organize her data from any location. Desktop on web can be named as WEBtop. This paper starts with a introduction of WebOS and its benefits. For this paper We have reviewed some most interesting WebOS available nowadays and tried to provide a detailed description of their features. We have identified some parameters as comparison criteria among them. A technical review is given with research design and future goals to design better web based operating systems is a part of this study. Findings of the study conclude this paper.

M. K. Sharma; Rajeev Kumar

2011-01-01T23:59:59.000Z

267

California's LNG Terminals: The Promise of New Gas Supplies  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

LNG Terminals: The LNG Terminals: The Promise of New Gas Supplies November 28, 2007 © 2005 San Diego Gas and Electric and Southern California Gas Company. All copyright and trademark rights reserved What is LNG? LNG is natural gas that has been liquefied, by cooling it to a temperature of -260°F, so it can be shipped across oceans. The gas is then re-vaporized and delivered to customers. 2 Why Do We Need LNG? California Energy Commission * 2007 Integrated Energy Policy Report -North American gas demand to increase at annual rate of 2.1% over next decade -Domestic production expected to remain flat -LNG imports to US expected to increase 14% annually by 2017 3 4 Benefits of LNG * Reduced energy costs for customers * Increased competition between gas suppliers * Improved reliability for customers

268

Completion of decommissioning: Monitoring for site release and license termination  

SciTech Connect

To request termination of a license upon completion of dismantling or decommissioning activities, documenting any residual radioactivity to show that the levels are environmentally acceptable will be necessary. When the regulators approve the decommissioning plan, they establish what the release criteria for the decommissioned site will be at the time of the site release and license termination. The criteria are numeric guidelines for direct radiation in soils and on surfaces. If the regulatory body finds that the measured on-site values are below the guidelines, the site will be acceptable for unrestricted release (no radiological controls or future use). If areas are found above those values, more decontamination or cleanup of these areas may be required unless the regulatory body grants an exemption.

Boing, L.E.

1997-08-01T23:59:59.000Z

269

Categorical Exclusion Determinations: Idaho Operations Office | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

November 28, 2011 November 28, 2011 CX-007774: Categorical Exclusion Determination Rensselaer Infrastructure Upgrade to Enhance Research and Education in Nuclear Engineering - Rensselaer Polytechnic Institute CX(s) Applied: B3.6 Date: 11/28/2011 Location(s): New York Offices(s): Nuclear Energy, Idaho Operations Office November 28, 2011 CX-007773: Categorical Exclusion Determination An Integrated Upgrade of Scientific Equipment for Strengthening the Research and Education in Nuclear Energy at the Ohio State University CX(s) Applied: B1.2, B3.6 Date: 11/28/2011 Location(s): Ohio Offices(s): Nuclear Energy, Idaho Operations Office November 28, 2011 CX-007772: Categorical Exclusion Determination Idaho National Laboratory Asphalt Repair Project - North Wind Services, LLC CX(s) Applied: B1.3

270

Categorical Exclusion Determinations: Idaho Operations Office | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

May 22, 2012 May 22, 2012 CX-008744: Categorical Exclusion Determination Implementation of a Low-Level Gamma-Ray Counting Facility - University of Texas at Austin CX(s) Applied: B3.6 Date: 05/22/2012 Location(s): Idaho Offices(s): Idaho Operations Office May 22, 2012 CX-008738: Categorical Exclusion Determination Determination of Microstructure and Chemical State Changes in Ion-Irradiated Fuels and Structural Components with a High Kinetic Energy Electron Detector - Illinois Institute of Technology CX(s) Applied: B3.6 Date: 05/22/2012 Location(s): Idaho Offices(s): Idaho Operations Office May 22, 2012 CX-008737: Categorical Exclusion Determination Building Calorimetric and Thermogravimetric Analytical Instrumentation Capability at Oregon State University CX(s) Applied: B3.6 Date: 05/22/2012

271

LM340/LM78MXX Series 3-Terminal Positive Regulators  

E-Print Network (OSTI)

LM340/LM78MXX Series 3-Terminal Positive Regulators General Description The LM140/LM340A/LM340/LM. The LM340A/LM340/LM7800C series is available in the TO-220 plastic power package, and the LM340-5.0 is available in the SOT-223 package, as well as the LM340-5.0 and LM340-12 in the surface-mount TO-263 package

Ravikumar, B.

272

LM340/LM78XX Series 3-Terminal Positive Regulators  

E-Print Network (OSTI)

LM340/LM78XX Series 3-Terminal Positive Regulators General Description The LM140/LM340A/LM340/LM. The LM340A/LM340/LM7800C series is available in the TO-220 plastic power package, and the LM340-5.0 is available in the SOT-223 package, as well as the LM340-5.0 and LM340-12 in the surface-mount TO-263 package

Goldwasser, Shafi

273

United States National Waste Terminal Storage argillaceous rock studies  

SciTech Connect

The past and present argillaceous rock studies for the US National Waste Terminal Storage Program consist of: (1) evaluation of the geological characteristics of several widespread argillaceous formations in the United States; (2) laboratory studies of the physical and chemical properties of selected argillaceous rock samples; and (3) two full-scale in situ surface heater experiments that simulate the emplacement of heat-generating radioactive waste in argillaceous rock.

Brunton, G.D.

1981-01-01T23:59:59.000Z

274

(sanitary) landfill operator  

Science Journals Connector (OSTI)

(sanitary) landfill operator, Mllkippenbetreiber m, Mlldeponiebetreiber, Kippenbetreiber, Deponiebetreiber

2014-08-01T23:59:59.000Z

275

AG Plus Co operative | Open Energy Information  

Open Energy Info (EERE)

Plus Co operative Plus Co operative Jump to: navigation, search Name AG Plus Co-operative Place SE Kindred, North Dakota Zip 58051 Product Cooperative offering membership stock to agricultural producers. Set up to assist with the financing of a soybean crushing plant in the town of Kindred. References AG Plus Co-operative[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. AG Plus Co-operative is a company located in SE Kindred, North Dakota . References ↑ "AG Plus Co-operative" Retrieved from "http://en.openei.org/w/index.php?title=AG_Plus_Co_operative&oldid=341858" Categories: Clean Energy Organizations Companies Organizations Stubs What links here Related changes

276

Export.gov - Export.gov - Locations  

NLE Websites -- All DOE Office Websites (Extended Search)

Locations Locations Print | E-mail Page Locations 800.872.8723 Domestic Offices International Offices Locations 800.872.8723 Call: 800.872.8723 (1-800-USA-TRAD(E)) Email: tic@trade.gov between 8:30 AM and 6 PM EST to receive immediate answers to your exporting questions on: Tariff and Tax Information Country-specific General Export Information Region-specific Export Information (Middle East, China, Latin America, EU, etc.) International Documentation, Regulations and Standards Logistics and Finance (HS/Schedule B numbers, Freight Forwarders, partners) Free Trade Agreements (qualifying products for FTA benefits, Certificates of origin.) Trade Data Export-related information offered by federal, state and local entities Export-related information related to other USG agencies Note for Importers: Please contact U.S. Customs at 877.227.5511

277

Addressing endogeneity in residential location models  

E-Print Network (OSTI)

Some empirical residential location choice models have reported dwelling-unit price estimated parameters that are small, not statistically significant, or even positive. This would imply that households are non-sensitive ...

Guevara-Cue, Cristin Angelo

2005-01-01T23:59:59.000Z

278

Location privacy in mobile computing environments  

Science Journals Connector (OSTI)

In general, privacy can be viewed as the right to be left alone when desired (solitude), the right to remain anonymous (anonymity), and the right to confidentiality (secrecy of information). More specifically, location privacy is the ability to ...

John P. Baugh; Jinhua Guo

2006-09-01T23:59:59.000Z

279

Data semantics in location-based services  

Science Journals Connector (OSTI)

As location-based applications become part of our everyday life, ranging from traffic prediction systems to services over mobile phones providing us with information about our surroundings, the call for more semantics and accurate services is emerging. ...

Nectaria Tryfona; Dieter Pfoser

2005-01-01T23:59:59.000Z

280

Alternative Fueling Station Locator | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alternative Fueling Station Locator Alternative Fueling Station Locator Alternative Fueling Station Locator Find Stations Plan a Route Location: Go Start: End: Go Fuel: All Fuels Biodiesel (B20 and above) Compressed Natural Gas Electric Ethanol (E85) Hydrogen Liquefied Natural Gas (LNG) Liquefied Petroleum Gas (Propane) more search options close × More Search Options Include private stations Include planned stations Owner All Private Federal State Local Utility Payment All American Express Discover MasterCard VISA Cash Checks CFN Clean Energy Fuel Man Gas Card PHH Services Voyager WEX Electric charger types Include level 1 Include level 2 Include DC fast Include legacy chargers Limit results to within 5 miles Limit results to within 5 miles 12,782 alternative fuel stations in the United States Excluding private stations

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Location-Aware Instant Search Ruicheng Zhong  

E-Print Network (OSTI)

to find a gas station nearby, she can issue a keyword query "gas station" to a LBS system, which returns the relevant gas stations by considering the user's location and keywords. Traditional spatial keyword search

Li, Guoliang

282

Operations Directorate (OPS Directorate)  

NLE Websites -- All DOE Office Websites (Extended Search)

Operations Directorate (OPS Directorate) Operations Directorate (OPS Directorate) Purpose A group chartered by the Associate Laboratory Director for the Advanced Photon Source that includes the responsible Division Directors and other appropriate APS operations personnel. The Operations Directorate collectively coordinates operating decisions that affect the facility as a whole and establishes both long- and short-term schedules, including scheduled maintenance and facility improvement periods. The Operations Directorate is the APS forum in which decisions regarding operations are discussed: These include, but are not limited to: Safety issues related to operations Operational Schedule Global operating parameters within the defined and approved operational and safety envelopes, such as energy, maximum circulating beam

283

Challenges of Advanced Utilization of LNG Cold in Osaka Gas Senboku LNG Terminals  

Science Journals Connector (OSTI)

In this paper, we report the outline of the Senboku LNG terminals, with a focus on Terminal 1, and the facilities using the LNG cold. In addition, by evaluating the ... we consider the vision to improve utilizati...

Takayuki Yamamoto; Yukio Fujiwara

2012-01-01T23:59:59.000Z

284

Alpha Emission Near 100Sn and the Termination of the rp Process  

NLE Websites -- All DOE Office Websites (Extended Search)

Alpha Emission Near 100 Sn and the Termination of the rp Process The astrophysical rp-process is thought to reach a termination point in the region of 100 Sn, via the...

285

E-Print Network 3.0 - affects response termination Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

response is for the new terminal to suspend... transmission scheduling, when a terminal boots and is ready to join the network it has no knowledge... of the network's current...

286

Graphene flakes with defective edge terminations: Universal and topological aspects, and one-dimensional quantum behavior  

E-Print Network (OSTI)

Graphene flakes with defective edge terminations: Universal and topological aspects, and one graphene nanoflakes with reconstructed zigzag edges, where a succes- sion of pentagons and heptagons these spectra. The electronic spectra of trigonal graphene nanoflakes with reczag edge terminations exhibit

Yannouleas, Constantine

287

Ran's C-terminal, Basic Patch, and Nucleotide Exchange Mechanisms in Light of a Canonical  

E-Print Network (OSTI)

Ran's C-terminal, Basic Patch, and Nucleotide Exchange Mechanisms in Light of a Canonical Structure's basic patch and C-terminal switch to nucleotide exchange and effector binding. Other core components

Liu, Jun

288

E-Print Network 3.0 - amino-terminal fragment 1-431 Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

for: amino-terminal fragment 1-431 Page: << < 1 2 3 4 5 > >> 1 Proc. Natl. Acad. Sci. USA Vol. 84, pp. 4791-4795, July 1987 Summary: Da amino-terminal heparin-binding fragment,...

289

Hermitian Young operators  

SciTech Connect

Starting from conventional Young operators, we construct Hermitian operators which project orthogonally onto irreducible representations of the (special) unitary group.

Keppeler, Stefan, E-mail: stefan.keppeler@uni-tuebingen.de [Mathematisches Institut, Universitt Tbingen, Auf der Morgenstelle 10, 72076 Tbingen (Germany)] [Mathematisches Institut, Universitt Tbingen, Auf der Morgenstelle 10, 72076 Tbingen (Germany); Sjdahl, Malin, E-mail: malin.sjodahl@thep.lu.se [Department of Astronomy and Theoretical Physics, Lund University, Slvegatan 14A, 22362 Lund (Sweden)] [Department of Astronomy and Theoretical Physics, Lund University, Slvegatan 14A, 22362 Lund (Sweden)

2014-02-15T23:59:59.000Z

290

Locating and identifying codes in circulant networks  

Science Journals Connector (OSTI)

A set S of vertices of a graph G is a dominating set of G if every vertex u of G is either in S or it has a neighbour in S. In other words, S is dominating if the sets S@?N[u] where u@?V(G) and N[u] denotes the closed neighbourhood of u in G, are all ... Keywords: Circulant network, Domination, Identifying code, Locating code, Locating-dominating set

M. Ghebleh; L. Niepel

2013-09-01T23:59:59.000Z

291

Personal Digital Assistant PDA ----Location Based  

E-Print Network (OSTI)

, xur],[ ybl, yur ]) k k=100 K k k- AminAmin kLk k Amax TmaxTmax kAminLocation Anonymization ConstraintsAmax TmaxLocation Service Quality Constraints 3.3 3.3.1 id, loc, query id loc (x,y)query GPS / l- l- k- l- k l- l l- l- m-invariant 2 29 #12;[22] A B C D E F R1 R2 R3 6 Outlier 6

292

Environmental Impact Of Lng Terminals In The Gulf Of Trieste (Northern Adriatic)  

Science Journals Connector (OSTI)

The environmental impact of the proposed offshore gas terminal of LNG (Liquid Natural Gas) in the centre...

V. Mala?I?; J. Faganeli; A. Malej

2008-01-01T23:59:59.000Z

293

Cool heliosheath plasma and deceleration of the upstream solar wind at the termination shock  

E-Print Network (OSTI)

with respect to the ther- mal ions downstream of the termination shock. Most of the solar wind energy

Richardson, John

294

The Value of Flexibility in Robust Location-Transportation Problem  

E-Print Network (OSTI)

production and distribution of products can be delayed until actual orders are ... such as hub locations, supplier locations, air freight hub locations, railway station

2014-11-24T23:59:59.000Z

295

Regenerator Location Problem in Flexible Optical Networks  

E-Print Network (OSTI)

Using real world network topologies, we conduct extensive numerical .... it to the operations research literature, proving its NP-completeness and showing.

2014-11-22T23:59:59.000Z

296

Nonlinear Control Design and Analysis of a Multi-Terminal VSC-HVDC System  

E-Print Network (OSTI)

Nonlinear Control Design and Analysis of a Multi-Terminal VSC-HVDC System Yijing Chen1, Jing Dai1-terminal voltage- source converter based high-voltage direct current (multi- terminal VSC-HVDC) system-Source Converter based High-Voltage Direct Current (VSC-HVDC) multipoint networks could be a good solution

Paris-Sud XI, Université de

297

2:00-2:30 Beverages, 2:30-4 PM Seminar Chevron operates two refineries on the west coast of California. Large parcels of  

E-Print Network (OSTI)

4/18/2014 2:00-2:30 Beverages, 2:30-4 PM Seminar Abstract Chevron operates two refineries fuel must be moved between the refineries by ship to balance production. The El Segundo Marine Terminal these vapors are returned to the refinery for processing via a vapor return pipeline. El Segundo's terminal

298

Medford Operation Biomass Facility | Open Energy Information  

Open Energy Info (EERE)

Medford Operation Biomass Facility Medford Operation Biomass Facility Jump to: navigation, search Name Medford Operation Biomass Facility Facility Medford Operation Sector Biomass Location Jackson County, Oregon Coordinates 42.334535°, -122.7646577° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.334535,"lon":-122.7646577,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

299

Systems simulation of oil additives to grain at terminal elevators  

E-Print Network (OSTI)

in Missouri and Texas. Several of these elevators are using oil additives on a regular basis. In addition to grain samples, operating data such as equipment capacities, operating hours and volume of grain handled were obtained. The grain samples were... in Missouri and Texas. Several of these elevators are using oil additives on a regular basis. In addition to grain samples, operating data such as equipment capacities, operating hours and volume of grain handled were obtained. The grain samples were...

Goforth, Kerry James

2012-06-07T23:59:59.000Z

300

Alternative Fueling Station Locations | OpenEI  

Open Energy Info (EERE)

Alternative Fueling Station Locations Alternative Fueling Station Locations Dataset Summary Description Alternative fueling stations are located throughout the United States and their availability continues to grow. The Alternative Fuels Data Center (AFDC) maintains a website where you can find alternative fuels stations near you or on a route, obtain counts of alternative fuels stations by state, view U.S. maps, and more. Access up-to-date fuel station data here: http://www.afdc.energy.gov/afdc/data_download The dataset available for download here provides a "snapshot" of the alternative fueling station information for: compressed natural gas (CNG), E85 (85% ethanol, 15% gasoline), propane/liquefied petroleum gas (LPG), biodiesel, electricity, hydrogen, and liquefied natural gas

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Open neighborhood locatingdominating in trees  

Science Journals Connector (OSTI)

For a graph G that models a facility or a multiprocessor network, detection devices can be placed at the vertices so as to identify the location of an intruder such as a thief or saboteur or a faulty processor. Open neighborhood locatingdominating sets are of interest when the intruder/fault at a vertex precludes its detection at that location. The parameter OLD ( G ) denotes the minimum cardinality of a vertex set S ? V ( G ) such that for each vertex v in V ( G ) its open neighborhood N ( v ) has a unique non-empty intersection with S . For a tree T n of order n we have ? n / 2 ? + 1 ? OLD ( T n ) ? n ? 1 . We characterize the trees that achieve these extremal values.

Suk J. Seo; Peter J. Slater

2011-01-01T23:59:59.000Z

302

The pipeline and valve location problem  

Science Journals Connector (OSTI)

This paper, proposes an exact algorithm for the problem of locating a pipeline between two points of a network, as well as a set of safety valves which help control the damage caused by possible spills along the pipeline. A labelling approach is developed to determine simultaneously the optimal pipeline and valve locations, with the objective of optimising an impact measure that depends on the average number of accidents and their cost. Computational experiments on grid and random instances are presented in order to evaluate the algorithm's performance and to compare its results to the solutions provided by sequential approaches. [Received 11 May 2010; Revised 10 October 2010; Accepted 21 November 2010

Gilbert Laporte; Marta M.B. Pascoal

2012-01-01T23:59:59.000Z

303

Driver expectancy in locating automotive controls  

E-Print Network (OSTI)

to determine if any of these factors had any effect on the distributions of control locations. In the final phase of the study McGrath measured response time and errors in locating controls in two cars, one was a 1973 Toyota and the other a 1973 Buick..., Chrysler, and Dodge. Also included were the following far eastern car makes: Toyota, Honda, Mazda, Hyundai, Isuzu, Nissan, and Geo. The automobiles were divided into six groups: 14 1. Foreign-make, small, mid-size, and sports cars. 2. Foreign...

Francis, Dawn Suzette

1990-01-01T23:59:59.000Z

304

Experiences with a two terminal-pair digital impedance bridge  

E-Print Network (OSTI)

This paper describes the realization of a two terminal-pair digital impedance bridge and the test measurements performed with it. The bridge, with a very simple architecture, is based on a commercial two-channel digital signal synthesizer and a synchronous detector. The bridge can perform comparisons between impedances having arbitrary phase and magnitude ratio: its balance is achieved automatically in less than a minute. $R$-$C$ comparisons with calibrated standards, at kHz frequency and 100 kohm magnitude level, give ratio errors of the order of $10^{-6}$, with potential for further improvements.

Callegaro, Luca; Kampik, Marian; Kim, Dan Bee; Ortolano, Massimo; Pourdanesh, Faranak

2014-01-01T23:59:59.000Z

305

Computers & Operations Research 32 (2005) 22552269 www.elsevier.com/locate/dsw  

E-Print Network (OSTI)

) scheduling rule to determine the order of serving data packets. This scheduling rule does not provide quality-Cheng Lai, Toni Farley Information and Systems Assurance Laboratory, Arizona State University, P.O. Box priorities and the enhancement of routing performance. We develop a scheduling rule called Weighted Shortest

Lai, Ying-Cheng

306

Location-based advertising in an emerging market: a study of Mongolian mobile phone users  

Science Journals Connector (OSTI)

With the advances in communication and location-based technology, location-based advertising has been used frequently for mobile advertising. However, scholarly works regarding location-based advertising are still few and far between. This study examines the significance of association between format of advertisement, product involvement, privacy, and brand credibility and consumers' attitudes towards the location-based advertising. The relationship between attitudes towards the location-based advertising and attitudes towards brands is also investigated. The experimental design with web surveys was conducted on 464 staff members of MobiCom Corporation, the largest mobile phone operator in Mongolia. Results show that animated location-based advertising, less personal information embedded advertisement message and foreign-brand products advertised through location-based advertising are significant contributors to a positive attitude towards location-based advertising. Moreover, there is a statistically significant relationship between attitude towards the location-based advertising and attitude towards brands. The implications of the findings are provided.

Jengchung V. Chen; Bo-chiuan Su; David C. Yen

2014-01-01T23:59:59.000Z

307

Rack Locations (24) Hatch and Berthing  

E-Print Network (OSTI)

Rack Locations (24) Hatch and Berthing Mechanism Endcone Airflow and Plumbing Crossover Corner requirements of 24 equipment racks. Approximately half of these are for accommodation and control of ISS ) Width 4.3 m diameter (14 ft) Mass 14,515 kg (32,000 lb) 24,023 kg (52,962 lb) with all racks

308

Transportation Networks and Location A Geometric Approach  

E-Print Network (OSTI)

Transportation Networks and Location A Geometric Approach Belén Palop1,2 1Departamento de March 2009 Florida State University #12;Belén Palop, UVa, SUNY Outline Transportation Network Model;Transportation Network Model Belén Palop, UVa, SUNY Outline Transportation Network Model Network placement

Palop del Río, Belén

309

Forecasting the Locational Dynamics of Transnational Terrorism  

E-Print Network (OSTI)

Forecasting the Locational Dynamics of Transnational Terrorism: A Network Analytic Approach Bruce A-0406 Fax: (919) 962-0432 Email: skyler@unc.edu Abstract--Efforts to combat and prevent transnational terror of terrorism. We construct the network of transnational terrorist attacks, in which source (sender) and target

Massachusetts at Amherst, University of

310

Recycling Bin Guide Locations and prices  

E-Print Network (OSTI)

Recycling Bin Guide Locations and prices Metal Bins Deskside Bins with Side Saddle Rubbermaid Bins.58 for auxiliaries. And Non-Public Areas Public Offices Non-Public Recyclables Recyclables RecyclablesTrash Trash Trash #12;New Recycling Bin Guidelines Frequently Asked Questions (as of December 2008) · Why

Kirschner, Denise

311

Location management and Moving Objects Databases  

E-Print Network (OSTI)

wolfson@cs.uic.edu #12;2 Location based services Examples: Where closest gas station? How do I get there;13 Applications-- Summary · Geographic resource discovery-- e.g. "Closest gas station" · Digital Battlefield/trigger examples: · During the past year, how many times was bus#5 late by more than 10 minutes at station 20

Wolfson, Ouri E.

312

Therapy: location-aware assessment and tasks  

Science Journals Connector (OSTI)

In this paper, we present a system that allows therapists to assess and engage patients' in activities triggered by specific stressing contexts. The system is composed by: 1) a web application that the therapist uses to specify the activities and its ... Keywords: location based services, physiological recording, therapy

Lus Carrio; Marco de S; Lus Duarte; Tiago Antunes

2012-03-01T23:59:59.000Z

313

JLF Conduct of Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Jupiter Laser Facility (JLF) Conduct Of Operations The Conduct of Operations is a set of procedures and guidelines that are put in place to ensure operational safety and security...

314

Heat Transfer Operators Associated with Quantum Operations  

E-Print Network (OSTI)

Any quantum operation applied on a physical system is performed as a unitary transformation on a larger extended system. If the extension used is a heat bath in thermal equilibrium, the concomitant change in the state of the bath necessarily implies a heat exchange with it. The dependence of the average heat transferred to the bath on the initial state of the system can then be found from the expectation value of a hermitian operator, which is named as the heat transfer operator (HTO). The purpose of this article is the investigation of the relation between the HTOs and the associated quantum operations. Since, any given quantum operation on a system can be realized by different baths and unitaries, many different HTOs are possible for each quantum operation. On the other hand, there are also strong restrictions on the HTOs which arise from the unitarity of the transformations. The most important of these is the Landauer erasure principle. This article is concerned with the question of finding a complete set of restrictions on the HTOs that are associated with a given quantum operation. An answer to this question has been found only for a subset of quantum operations. For erasure operations, these characterizations are equivalent to the generalized Landauer erasure principle. For the case of generic quantum operations however, it appears that the HTOs obey further restrictions which cannot be obtained from the entropic restrictions of the generalized Landauer erasure principle.

. Aksak; S. Turgut

2011-04-14T23:59:59.000Z

315

Modal Analysis for Grid Operation  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Presenter: Ning Zhou Pacific Northwest National Laboratory ning.zhou@pnnl.gov 27/28 June 2013 Washington, DC DOE/OE Transmission Reliability Program Past Oscillation Event - 1996/08/10 [bitmap version 1100 1200 1300 1400 1500 15:42:03 15:48:51 15:47:36 Power (MW) August 10, 1996 Western Power System Breakup California-Oregon Intertie Time Domain ~ -3.1% < ~3.5% Damping ~ 8.4% Early Warning ~6 minutes Freq Domain Project Objective  Ways to Improve Damping - Power System Stabilizer (PSS): parameters pre-tuned based on off-line scenarios - Reactive Support: locations pre-selected based on off-line scenarios - Adjustment of Operator Controllable Variables : operator actions determined with the on-line scenarios  Objective of this Project:

316

Transmission of sound through suspended ceilings from HVAC terminal units  

Science Journals Connector (OSTI)

An ASHRAE project to investigate factors determining the sound pressure levels in rooms below ceilings concealing air?terminal units has been completed. Four terminal units installed close to the six ceiling types used were the major noise sources. They were supplemented by two simulators powered by loudspeakers. Sound power was measured for each device in the 156 cubic meter test room in its reverberant condition. The levels in the room were measured for each combination of source and ceiling tile. Sound pressure level was measured as a function of distance from two sources in the room below. The main intent of the project was to validate ARI Standard 885 which provides a calculation method for such situations. Differences among ceiling types were less than expected; leakage around the edges of each panel is a dominant transmission path. Ceiling attenuations at low frequencies were found to depend on the area of the lower face of the units. Sound levels in the room were essentially uniform when the source was above the ceiling. The decay of sound with distance from the sources below the ceiling was found to depend on the inverse of the room reverberation time.

Alf Warnock

1998-01-01T23:59:59.000Z

317

STANDARD OPERATING PROCEDURE HEAVY METAL SALTS (selected)  

E-Print Network (OSTI)

MSDS ___Special training provided by the department/supervisor ___Review of the OSHA Lab Standard ___Review of the departmental safety manual ___Review of the Chemical Hygiene Plan ___Safety meetings12.1 STANDARD OPERATING PROCEDURE for HEAVY METAL SALTS (selected) Location

Pawlowski, Wojtek

318

Employer Handbook Co-operative Education Program  

E-Print Network (OSTI)

1 Employer Handbook Co-operative Education Program Faculty of Arts University of Calgary #12. This handbook is your guide to the Co-op process at the University of Calgary and should ensure a rewarding management resources Provide connections to Career Services on campus The physical location and mailing

Habib, Ayman

319

Chance-Constrained Multi-Terminal Network Design Problems  

E-Print Network (OSTI)

May 7, 2014 ... Department of Statistical Sciences and Operations Research, Virginia ...... We conduct our computational experiments using the branch-and-cut...

2014-05-07T23:59:59.000Z

320

OPTIMALSENSOR PLACEMENT METHODOLOGY FOR OPERATIONAL MODALSYSTEM IDENTIFICATION OFA  

E-Print Network (OSTI)

vibration testing (also called operational modal analysis (OMA)). In OMA, the measurement locations field vibration test. The singularity and importance of such structure require easier, quicker and cheaper monitoring methods. Vibration- based health monitoring methods determine the modal characteristics

Boyer, Edmond

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

On -locatingdominating sets in paths  

Science Journals Connector (OSTI)

Assume that G = ( V , E ) is a simple undirected graph, and C is a nonempty subset of V . For every v ? V , we define I r ( v ) = { u ? C ? d G ( u , v ) ? r } , where d G ( u , v ) denotes the number of edges on any shortest path between u and v . If the sets I r ( v ) for v ? C are pairwise different, and none of them is the empty set, we say that C is an r -locatingdominating set in G . It is shown that the smallest 2-locatingdominating set in a path with n vertices has cardinality ? ( n + 1 ) / 3 ? , which coincides with the lower bound proved earlier by Bertrand, Charon, Hudry and Lobstein. Moreover, we give a general upper bound which improves a result of Bertrand, Charon, Hudry and Lobstein.

Iiro Honkala

2009-01-01T23:59:59.000Z

322

Human immunodeficiency virus long terminal repeat responds to T-cell activation signals  

SciTech Connect

Human immunodeficiency virus (HIV), the causative agent of AIDS, infects and kills lymphoid cells bearing the CD4 antigen. In an infected cell, a number of cellular as well as HIV-encoded gene products determine the levels of viral gene expression and HIV replication. Efficient HIV replication occurs in activated T cells. Utilizing transient expression assays, the authors show that gene expression directed by the HIV long terminal repeat (LTR) increases in response to T-cell activation signals. The effects of T-cell activation and of the HIV-encoded trans-activator (TAT) are multiplicative. Analysis of mutations and deletions in the HIV LTR reveals that the region responding to T-cell activation signals is located at positions -105 to -80. These sequences are composed of two direct repeats, which are homologous to the core transcriptional enhancer elements in the simian virus 40 genome. The studies reveal that these elements function as the HIV enhancer. By acting directly on the HIV LTR, T-cell activation may play an important role in HIV gene expression and in the activation of latent HIV.

Tong-Starksen, S.E.; Luciw, P.A.; Peterlin, B.M.

1987-10-01T23:59:59.000Z

323

Automated Fault Location In Smart Distribution Systems  

E-Print Network (OSTI)

measured at the power substation during a single phase to ground fault clearance [17] .............................................. 111 Figure 26 Analyzed signal using wavelet transform from phase B current during a fault [17..., but are not limited to, substation and feeder relay, intelligent controllers for capacitor bank switches or reclosers, Automatic Meter Reading (AMR) systems installed at the customer sites, power quality meters installed at strategic locations in the system, low...

Lotfifard, Saeed

2012-10-19T23:59:59.000Z

324

Truckstop Electrification Locator | Open Energy Information  

Open Energy Info (EERE)

Truckstop Electrification Locator Truckstop Electrification Locator Jump to: navigation, search Tool Summary Name: Truckstop Electrification Locator Agency/Company /Organization: United States Department of Energy Phase: "Evaluate Options and Determine Feasibility" is not in the list of possible values (Bring the Right People Together, Create a Vision, Determine Baseline, Evaluate Options, Develop Goals, Prepare a Plan, Get Feedback, Develop Finance and Implement Projects, Create Early Successes, Evaluate Effectiveness and Revise as Needed) for this property., "Perpare a Plan" is not in the list of possible values (Bring the Right People Together, Create a Vision, Determine Baseline, Evaluate Options, Develop Goals, Prepare a Plan, Get Feedback, Develop Finance and Implement Projects, Create Early Successes, Evaluate Effectiveness and Revise as Needed) for this property., "Implement the Plan" is not in the list of possible values (Bring the Right People Together, Create a Vision, Determine Baseline, Evaluate Options, Develop Goals, Prepare a Plan, Get Feedback, Develop Finance and Implement Projects, Create Early Successes, Evaluate Effectiveness and Revise as Needed) for this property.

325

Locating and identifying codes in circulant networks  

Science Journals Connector (OSTI)

Abstract A set S of vertices of a graph G is a dominating set of G if every vertex u of G is either in S or it has a neighbour in S . In other words, S is dominating if the sets S ? N [ u ] where u ? V ( G ) and N [ u ] denotes the closed neighbourhood of u in G , are all nonempty. A set S ? V ( G ) is called a locating code in G , if the sets S ? N [ u ] where u ? V ( G ) ? S are all nonempty and distinct. A set S ? V ( G ) is called an identifying code in G , if the sets S ? N [ u ] where u ? V ( G ) are all nonempty and distinct. We study locating and identifying codes in the circulant networks C n ( 1 , 3 ) . For an integer n ? 7 , the graph C n ( 1 , 3 ) has vertex set Z n and edges x y where x , y ? Z n and | x ? y | ? { 1 , 3 } . We prove that a smallest locating code in C n ( 1 , 3 ) has size ? n / 3 ? + c , where c ? { 0 , 1 } , and a smallest identifying code in C n ( 1 , 3 ) has size ? 4 n / 11 ? + c ? , where c ? ? { 0 , 1 } .

M. Ghebleh; L. Niepel

2013-01-01T23:59:59.000Z

326

Mission Operations & Data Systems  

E-Print Network (OSTI)

Mission Operations & Data Systems The LASP Mission Operations & Data Systems (MO&DS) group staffs and instruments. Operational software acts like the health systems in a body, ensuring that temperature, energy. The software monitors the health of on-board systems; anything unusual is flagged and sent to mission operators

Mojzsis, Stephen J.

327

Laser Controlled Area Standard Operating Procedure (SOP)  

NLE Websites -- All DOE Office Websites (Extended Search)

PS-ESH-0025 PS-ESH-0025 01 Effective: Page 1 of 13 03/09/2012 Subject: Laser Safety Program Documentation X17C The only official copy of this file is the one on-line in the NSLS ESH website. Before using a printed copy, verify that it is the most current version by checking the document issue date on the NSLS ESH website. BROOKHAVEN NATIONAL LABORATORY LASER CONTROLLED AREA STANDARD OPERATING PROCEDURE (SOP) X17C Laser System System description: There is one laser at X17C: Diode-Pumped Solid State Laser (Class 3B) that has two uses: - Measurement of diamond anvil pressure from ruby fluorescence - Raman spectrum measurements Location: The DPSS laser system is located in NSLS room 1-134C LINE MANAGEMENT RESPONSIBILITIES The Owner/Operator for this laser is listed below. The Owner/Operator is the Line Manager of the system

328

ARM - SGP Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Operations Operations SGP Related Links Facilities and Instruments Central Facility Boundary Facility Extended Facility Intermediate Facility Radiometric Calibration Facility Geographic Information ES&H Guidance Statement Operations Science Field Campaigns Visiting the Site Fact Sheet Images Information for Guest Scientists Contacts SGP Operations Routine Operations SGP central facility offices. SGP central facility offices. The overwhelming majority of the measurements with the highest priority, on which the existing experimental designs are based, are regular routine observations, as specified in the ARM Program Plan, 1990 (U.S. Department of Energy 1990). Scientifically and logistically, routine operations also serve as the basis and background for all nonroutine operations, including

329

Multi-terminal Subsystem Model Validation for Pacific DC Intertie  

SciTech Connect

this paper proposes to validate dynamic model of Pacific DC Intertie with the concept of hybrid simulation by combing simulation with PMU measurements. The Playback function available in GE PSLF is adopted for hybrid simulation. It is demonstrated for the first time the feasibility of using Playback function on multi-terminal subsystem. Sensitivity studies are also presented as a result of common PMU measurement quality problem, ie, offset noise and time synchronization. Results indicate a good tolerance of PDCI model generally. It is recommended that requirements should apply to phasor measurements in model validation work to ensure better analysis. Key parameters are identified based on impact of value change to model behavior. Two events are employed for preliminary model validation with PMU measurements. Suggestions are made for PDCI model validation work in the future.

Yang, Bo; Huang, Zhenyu; Kosterev, Dmitry

2008-07-20T23:59:59.000Z

330

Hyperreal Waves on Transfinte, Terminated, Distortionless and Lossless, Transmission Lines  

E-Print Network (OSTI)

A prior work (see Chapter 8 of the book, ``Graphs and Networks: Transfinite and Nonstandard,'' Birkhauser-Boston, Cambridge, Mass., USA, 2004) examined the propagation of an electromagnetic wave on a transfinite transmission line, transfinite in the sense that infinitely many one-way infinite transmission lines are connected in cascade. That there are infinitely many such one-way infinite lines results in the wave propagating without ever reflecting at some discontinuity. The present work examines the cascade where the cascade terminates after only finitely many one-way infinite transmission lines, with the result that reflected waves are now produced at both the far end as well as at the initial end of the transfinite transmission line. The question of whether the reflected waves are infini tesimal or appreciable and whether they sum to an infinitesimal or appreciable amount are resolved for both distortionless and lossless lines. Finally, the generalizations to higher ranks of transfiniteness is briefly summarized.

A. H. Zemanian

2004-06-10T23:59:59.000Z

331

Table 2. Change in the Number of Personal Computers and Computer Terminals  

U.S. Energy Information Administration (EIA) Indexed Site

2 PC's and Computer Terminals 2 PC's and Computer Terminals Table 2. Change in the Number of Personal Computers and Computer Terminals in Commercial Buildings, 1992 to 1995 PCs and Terminals (thousand) PCs and Terminals per Thousand Employees PCs and Terminals per Million Sq. Ft. 1992 1995 Change (percent) 1992 1995 Change (percent) 1992 1995 Change (percent) All Buildings 29,752 43,003 45 431 571 32 463 732 58 Principal Building Activity Assembly 845 1,763 109 167 258 54 102 262 157 Education 6,004 8,046 34 877 847 -3 710 1,039 46 Food Sales 85 206 142 101 316 213 113 321 184 Food Service 146 276 89 65 118 82 98 204 108 Health Care 1,128 2,549 126 334 569 70 641 1,092 70 Lodging 651 1,296 99 322 472 47 225 358 59

332

U-027: RSA Key Manager Appliance Session Logout Bug Fails to Terminate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7: RSA Key Manager Appliance Session Logout Bug Fails to 7: RSA Key Manager Appliance Session Logout Bug Fails to Terminate Sessions U-027: RSA Key Manager Appliance Session Logout Bug Fails to Terminate Sessions November 4, 2011 - 8:00am Addthis PROBLEM: RSA Key Manager Appliance Session Logout Bug Fails to Terminate Sessions. PLATFORM: RSA Key Manager Appliance 2.7 Service Pack 1 ABSTRACT: A remote authenticated user session may not terminate properly. reference LINKS: SecurityTracker Alert ID: 1026276 SecurityFocus Bug Traq Seclists: ESA-2011-035 CVE-2011-2740 IMPACT ASSESSMENT: Medium Discussion: A vulnerability was reported in RSA Key Manager Appliance. A remote authenticated user session may not terminate properly. When using Firefox 4 and 5, an authenticated user session is not terminated properly when logging out.

333

Analysis Of Comptel Gamma-Ray Burst Locations And Spectra  

E-Print Network (OSTI)

. In its first three years of operation, the COMPTEL instrument on the Compton Gamma-Ray Observatory has measured the locations (mean accuracy 1 ffi ) and spectra (0.75--30 MeV) of 18 gamma-ray bursts and continues to observe new events at a rate of 1/month. With good angular resolution and sensitivity at MeV energies, the growing COMPTEL burst catalog is an important new piece of evidence in the on-going GRB mystery. The COMPTEL burst locations are consistent with an isotropic distribution of sources, yet the spatial coincidence of two of the bursts indicates the possibility of repetition. The COMPTEL burst spectra are in most cases consistent with a single power law model with spectral index in the range 2--3. However, two bursts show evidence of a spectral break in the MeV range. Measurement of rapid variability at MeV energies in the stronger bursts provides evidence that either the sources are nearby (within the Galaxy) or the gamma-ray emission is relativistically beamed. W...

Kippen Ryan; J. Ryan; A. Connors; M. Mcconnell; C. Winkler; L. O. Hanlon; J. Greiner; M. Varendorff; W. Collmar; W. Hermsen; L. Kuiper

334

Separation and Volatility of Locational Marginal Prices in Restructured Wholesale Power Markets  

E-Print Network (OSTI)

Test Bed I. INTRODUCTION THE wholesale power market design proposed by the U.S. Federal Energy1 Separation and Volatility of Locational Marginal Prices in Restructured Wholesale Power Markets (LMPs) in an ISO-managed restructured wholesale power market operating over an AC transmission grid

Tesfatsion, Leigh

335

Discrete Mathematics 233 (2001) 175182 www.elsevier.com/locate/disc  

E-Print Network (OSTI)

Discrete Mathematics 233 (2001) 175­182 www.elsevier.com/locate/disc Some remarks on cycles on cycles of graphs and directed graphs of the following form: `Does there exist a set of cycles with a property P that generates all the cycles by operation O?'. c 2001 Published by Elsevier Science B.V. 1

Matamala, Martín

336

What Really Matters in Locating Shared Humanitarian Stockpiles: Evidence from the WASH Cluster  

E-Print Network (OSTI)

as the water piping system will be deteriorated; if local water supply is still operational, water purification (e.g. bladder tanks, pipes, tanks, pumps and water purification items). The other are sanitation (e@Oxfam.org.uk Abstract. Through a case study of locating shared stockpiles at the United Nations Water Sanitation

Boyer, Edmond

337

The role of SCADA in developing a lean enterprise for municipal wastewater operations  

E-Print Network (OSTI)

Central to optimizing a wastewater system's operations is the collection of alarm and operational data from various remote locations throughout a municipality, hence the basic need for supervisory control and data acquisition ...

Prutz, Stanley J

2005-01-01T23:59:59.000Z

338

Idaho Operations Office  

NLE Websites -- All DOE Office Websites (Extended Search)

';b "* orl'W'f l - '75 ' Z' ' "Wi'ttrto% NEPA Document Title, Location, Document Number No MAPs anticipated Annual NEPA Planning Summary Mitigation Action Plan...

339

Positron Scanner for Locating Brain Tumors  

DOE R&D Accomplishments (OSTI)

A system is described that makes use of positron emitting isotopes for locating brain tumors. This system inherently provides more information about the distribution of radioactivity in the head in less time than existing scanners which use one or two detectors. A stationary circular array of 32 scintillation detectors scans a horizontal layer of the head from many directions simultaneously. The data, consisting of the number of counts in all possible coincidence pairs, are coded and stored in the memory of a Two-Dimensional Pulse-Height Analyzer. A unique method of displaying and interpreting the data is described that enables rapid approximate analysis of complex source distribution patterns. (auth)

Rankowitz, S.; Robertson, J. S.; Higinbotham, W. A.; Rosenblum, M. J.

1962-03-00T23:59:59.000Z

340

Alternative Fuels Data Center: Hydrogen Fueling Station Locations  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Hydrogen Hydrogen Printable Version Share this resource Send a link to Alternative Fuels Data Center: Hydrogen Fueling Station Locations to someone by E-mail Share Alternative Fuels Data Center: Hydrogen Fueling Station Locations on Facebook Tweet about Alternative Fuels Data Center: Hydrogen Fueling Station Locations on Twitter Bookmark Alternative Fuels Data Center: Hydrogen Fueling Station Locations on Google Bookmark Alternative Fuels Data Center: Hydrogen Fueling Station Locations on Delicious Rank Alternative Fuels Data Center: Hydrogen Fueling Station Locations on Digg Find More places to share Alternative Fuels Data Center: Hydrogen Fueling Station Locations on AddThis.com... More in this section... Hydrogen Basics Benefits & Considerations Stations Locations

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Alternative Fuels Data Center: Propane Fueling Station Locations  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane Propane Printable Version Share this resource Send a link to Alternative Fuels Data Center: Propane Fueling Station Locations to someone by E-mail Share Alternative Fuels Data Center: Propane Fueling Station Locations on Facebook Tweet about Alternative Fuels Data Center: Propane Fueling Station Locations on Twitter Bookmark Alternative Fuels Data Center: Propane Fueling Station Locations on Google Bookmark Alternative Fuels Data Center: Propane Fueling Station Locations on Delicious Rank Alternative Fuels Data Center: Propane Fueling Station Locations on Digg Find More places to share Alternative Fuels Data Center: Propane Fueling Station Locations on AddThis.com... More in this section... Propane Basics Benefits & Considerations Stations Locations Infrastructure Development

342

Major DOE Biofuels Project Locations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Major DOE Biofuels Project Locations More Documents & Publications Major DOE Biofuels Project Locations Slide 1 The Current State of Technology for Cellulosic Ethanol...

343

Alternative Fuels Data Center: Alternative Fueling Station Locator  

NLE Websites -- All DOE Office Websites (Extended Search)

Locate Stations Printable Version Share this resource Send a link to Alternative Fuels Data Center: Alternative Fueling Station Locator to someone by E-mail Share Alternative Fuels...

344

PARSII - New Reports and Reports With New Reporting Folder Location...  

Energy Savers (EERE)

- New Reports and Reports With New Reporting Folder Location More Documents & Publications PARSII - New Reports and Reports With New Reporting Folder Location Slide 1 Slide 1...

345

Alternative Fuels Data Center: Electric Vehicle Charging Station Locations  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Electric Vehicle Electric Vehicle Charging Station Locations to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Charging Station Locations on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Charging Station Locations on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Charging Station Locations on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Charging Station Locations on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Charging Station Locations on Digg Find More places to share Alternative Fuels Data Center: Electric Vehicle Charging Station Locations on AddThis.com... More in this section... Electricity Basics Benefits & Considerations Stations Locations Infrastructure Development

346

Conservation of Heat Energy at Hot Petroleum Products Terminals  

E-Print Network (OSTI)

optimum operating procedures to compare with present practices. 3. Develop a heat energy management information system. 4. Develop energy conservation expense/capital investment projects in order of attractiveness. STUDY APPROACH Comparison... REQUI REr1ENTS Additional effort will be required in 1981 to accomplish the overall objectives of this task force. The group will concentrate on changes in operating procedures to conserve fuel and on the development of an energy management...

Powell, J. C.; Graham, R. M.

1981-01-01T23:59:59.000Z

347

CONDUCT OF OPERATIONS (CO)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CONDUCT OF OPERATIONS (CO) CONDUCT OF OPERATIONS (CO) OBJECTIVE TA-55 SST Facility NNSA ORR Implementation Plan 1 1 CO.1 The formality and discipline of operations is adequate to conduct work safely and programs are inplace to maintain this formality and discipline. (Core Requirement 13) Criteria 1. Programmatic elements of conduct of operations are in place for TA-55 SST operations. 2. The TA-55 SST operations personnel adequately demonstrate the principles of conduct ofoperations requirements during the shift performance period. Approach Record Reviews: Review procedures and other facility documents to verify compliance with conduct of operations principles. Interviews: Interview a sampling of the TA-55 SST associated personnel to validate their understanding of the conduct of operations principles (e.g., procedure usage,

348

Transforming Commercial Building Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Transforming Commercial Building Operations Transforming Commercial Building Operations Transforming Commercial Building Operations Ron Underhill Pacific Northwest National Laboratory ronald.underhill@pnnl.gov (509)375-9765 April 4, 2013 2 | Building Technologies Office eere.energy.gov * Most buildings are not commissioned (Cx) before occupancy, including HVAC and lighting systems * Buildings often are poorly operated and maintained leading to significant energy waste of 5 to 20%, even when they have building automation systems (BASs)

349

Transforming Commercial Building Operations  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Transforming Commercial Building Operations Transforming Commercial Building Operations Transforming Commercial Building Operations Ron Underhill Pacific Northwest National Laboratory ronald.underhill@pnnl.gov (509)375-9765 April 4, 2013 2 | Building Technologies Office eere.energy.gov * Most buildings are not commissioned (Cx) before occupancy, including HVAC and lighting systems * Buildings often are poorly operated and maintained leading to significant energy waste of 5 to 20%, even when they have building automation systems (BASs)

350

Quantum Operations and Measurement  

E-Print Network (OSTI)

the Stinespring dilation form of E . 6 #12; II: operator­sum representation E(#) = Tr env # U(## # env )U

Seevinck, Michiel

351

Challenge # 3 ? Operational Issues  

Energy.gov (U.S. Department of Energy (DOE))

Fernando Preto presentation on May 9, 2012, at the Pyrolysis Oil Workshop on Challenge #3 Operational Issues.

352

Operations and maintenance philosophy  

SciTech Connect

This Operations and Maintenance (O&M) Philosophy document is intended to establish a future O&M vision, with an increased focus on minimizing worker exposure, ensuring uninterrupted retrieval operations, and minimizing operation life-cycle cost. It is intended that this document would incorporate O&M lessons learned into on-going and future project upgrades.

DUNCAN, G.P.

1999-10-28T23:59:59.000Z

353

Title, Location, Document Number Estimated Cost Description  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Moody to Lev, SUBJECT: NEPA 2012 APS for DOE-SRS, Dated: JAN 25 2012 Moody to Lev, SUBJECT: NEPA 2012 APS for DOE-SRS, Dated: JAN 25 2012 Title, Location, Document Number Estimated Cost Description EA Determination Date: uncertain Transmittal to State: uncertain EA Approval: uncertain FONSI: uncertain EA Determination Date: uncertain Transmittal to State: uncertain EA Approval: uncertain FONSI: uncertain Total Estimated Cost $65,000 Annual NEPA Planning Summary NEPA Reviews of Proposals to Implement Enterprise SRS Initiatives unknown The Savannah River Site Strategic Plan for 2011 - 2015 describes 12 initiatives that Enterprise SRS will pursue by applying SRS's management core competencies in nuclear materials. Implementation of new missions resulting from this effort will likely require NEPA review. However, until firm proposals are developed

354

Design of Bulk Railway Terminals for the Shale Oil and Gas Industry C. Tyler Dick1  

E-Print Network (OSTI)

Page 1 Design of Bulk Railway Terminals for the Shale Oil and Gas Industry C. Tyler Dick1 , P.E., M: Railway transportation is playing a key role in the development of many new shale oil and gas reserves in North America. In the rush to develop new shale oil and gas plays, sites for railway transload terminals

Barkan, Christopher P.L.

355

LM140/LM340A/LM340/LM7800C Series 3-Terminal Positive Regulators  

E-Print Network (OSTI)

LM140/LM340A/LM340/LM7800C Series 3-Terminal Positive Regulators General Description The LM140/LM340A/LM340/LM7800C monolithic 3-terminal positive voltage regulators employ internal current. The LM340A/LM340/LM7800C series is available in the TO-220 plastic power package, and the LM340

Wedeward, Kevin

356

Policies and Procedures for Creation, Review and Termination of Centers and Institutes  

E-Print Network (OSTI)

and Procedures have been adopted to provide a standard process for creating, review and terminating centersPolicies and Procedures for Creation, Review and Termination of Centers and Institutes March 3: The name of the new center or institute A mission statement and strategic plan, including a description

Escher, Christine

357

Econometric Modelling of World Oil Supplies: Terminal Price and the Time to Depletion  

E-Print Network (OSTI)

This paper develops a novel approach by which to identify the price of oil at the time of depletion; the so-called terminal price of oil. It is shown that while the terminal price is independent of both GDP growth and the price elasticity of energy...

Mohaddes, Kamiar

2012-03-02T23:59:59.000Z

358

Nutrient Management of Conservation-Till Cotton in Terminated-Wheat  

E-Print Network (OSTI)

Nutrient Management of Conservation- Till Cotton in Terminated-Wheat K.F. Bronson, J.W. Keeling, R, respectively. #12;A conservation-till cotton production system using wheat or rye winter cover, terminated (Lascano et al., 1994). Conservation-till cotton in the High Plains can be as productive as and more

Mukhtar, Saqib

359

Confirmed speakers include: THE GLOBAL ROLE OF VIRUSES IN BLOOM TERMINATION, BIODIVERSITY AND MARINE ECOLOGY  

E-Print Network (OSTI)

IN BLOOM TERMINATION, BIODIVERSITY AND MARINE ECOLOGY GUNNAR BRATBAK ­ University of Bergen, NorwayConfirmed speakers include: THE GLOBAL ROLE OF VIRUSES IN BLOOM TERMINATION, BIODIVERSITY AND MARINE ECOLOGY GUNNAR BRATBAK ­ University of Bergen, Norway COLLECTION, PROCESSING AND PRESERVATION

Wilhelm, Steven W.

360

Optimal Design of Remote Terminal Unit (RTU) for Wireless SCADA System for Energy Management  

Science Journals Connector (OSTI)

For energy deficit countries, the design of Supervisory Control and Data Acquisition (SCADA) based energy management systems for optimal distribution is of high interest. Such design involves development of Remote Terminal Unit (RTU) which is considered ... Keywords: Field Programmable Gate Array (FPGA), Programmable Logic Controller (PLC), Remote Terminal Unit (RTU), Supervisory Control and Data Acquisition (SCADA), Tele-Control Interface (TCI), Wireless Communication

Muhammad Aamir; Javier Poncela; Muhammad Aslam Uqaili; B. S. Chowdhry; Nishat Ahmad Khan

2013-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Small-Angle Neutron Scattering Studies of Charged Carboxyl-Terminated Dendrimers in Solutions  

E-Print Network (OSTI)

Small-Angle Neutron Scattering Studies of Charged Carboxyl-Terminated Dendrimers in Solutions Q. R-angle neutron scattering was used to characterize the solution behavior of charged carboxylic acid terminated- copy,16 small-angle X-ray scattering,17 and small-angle neutron scattering (SANS),18-25 have been used

Dubin, Paul D.

362

Instrument Grant Location CCSR 21XX Location CCSR 12XX Location SIM-1 BD FACSCalibur flow cytometer-2 laser/4 color Grant S-348A none none none  

E-Print Network (OSTI)

Instrument Grant Location CCSR 21XX Location CCSR 12XX Location SIM-1 BD FACSCalibur flow cytometer-2 laser/4 color Grant S-348A none none none BD FACScan flow cytometer 1 laser/3 color none CCSR 2121 none none Beckman Spectrophotometer(3) Grant S-348 CCSR 2122 CCSR 1210 none Chemilluminescence and Gel

Kay, Mark A.

363

CA3240, CA3240A Dual, 4.5MHz, BiMOS Operational Amplifier  

E-Print Network (OSTI)

with the industry standard 1458 operational amplifiers in similar packages. Functional Diagram Features · Dual Pb-free material sets; molding compounds/die attach materials and 100% matte tin plate termination1050.6 CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling

Lanterman, Aaron

364

Optimal Control of Airport Operations with Gate Capacity Constraints Harshad Khadilkar and Hamsa Balakrishnan  

E-Print Network (OSTI)

at Boston's Logan International Airport in the US are used to illustrate the advantages of the proposed for Boston Logan International Airport (BOS) is shown in Fig. 1. Gates at each of the four main terminalsOptimal Control of Airport Operations with Gate Capacity Constraints Harshad Khadilkar and Hamsa

Gummadi, Ramakrishna

365

Operational Monitoring of Weather Radar Receiving Chain Using the Sun IWAN HOLLEMAN  

E-Print Network (OSTI)

Operational Monitoring of Weather Radar Receiving Chain Using the Sun IWAN HOLLEMAN Royal, is presented. The ``online'' method is entirely based on the analysis of sun signals in the polar volume data- termining the weather radar antenna pointing at low elevations using sun signals, and it is suited

Stoffelen, Ad

366

Locating a Recycling Center: The General Density Case Jannett Highfill  

E-Print Network (OSTI)

Locating a Recycling Center: The General Density Case Jannett Highfill Department of Economics) 677-3374. #12;2 Locating a Recycling Center: The General Density Case Abstract: The present paper considers a municipality that has a landfill (fixed in location) and plans to optimally locate a "recycling

Mou, Libin

367

AVESTAR® - Operational Excellence for Clean Energy Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Operational Excellence for Clean Energy Systems Operational Excellence for Clean Energy Systems Chart The world-class Advanced Virtual Energy Simulation Training and Research (AVESTAR®) Center at the U.S. Department of Energy's National Energy Technology Laboratory (NETL) is dedicated to accelerating progress toward achieving operational excellence for commercial-scale, clean energy systems from smart plants to smart grid. With two locations in Morgantown, WV, one at the NETL and the other at West Virginia University's National Research Center for Coal and Energy, the AVESTAR Center is accomplishing its vital mission by bringing together: Advanced dynamic simulation, control, and virtual plant technologies Real-time, high-fidelity dynamic simulators with full-scope operator training systems (OTS)

368

Constellation Operating Services | Open Energy Information  

Open Energy Info (EERE)

Operating Services Operating Services Jump to: navigation, search Name Constellation Operating Services Place Fallon, Nevada Zip 89406 Sector Geothermal energy Product Operator of the Soda Lake geothermal plants. Coordinates 39.474905°, -118.777624° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":39.474905,"lon":-118.777624,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

369

NIF's Operations Support Building awarded LEED certification | National  

National Nuclear Security Administration (NNSA)

NIF's Operations Support Building awarded LEED certification | National NIF's Operations Support Building awarded LEED certification | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > NIF's Operations Support Building awarded LEED certification NIF's Operations Support Building awarded LEED certification Posted By Office of Public Affairs

370

V-204: A specially crafted query can cause BIND to terminate abnormally |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

V-204: A specially crafted query can cause BIND to terminate V-204: A specially crafted query can cause BIND to terminate abnormally V-204: A specially crafted query can cause BIND to terminate abnormally July 27, 2013 - 4:35am Addthis PROBLEM: A specially crafted query that includes malformed rdata can cause named to terminate with an assertion failure while rejecting the malformed query. PLATFORM: BIND 9.7 ABSTRACT: A specially crafted query sent to a BIND nameserver can cause it to crash (terminate abnormally). REFERENCE LINKS: ISC Knowledge Base CVE-2013-4854 IMPACT ASSESSMENT: High DISCUSSION: BIND is an implementation of the Domain Name System (DNS) protocols. Authoritative and recursive servers are equally vulnerable. Intentional exploitation of this condition can cause a denial of service in all nameservers running affected versions of BIND 9. Access Control Lists do

371

Alternative Fuels Data Center: Biodiesel Fueling Station Locations  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Station Locations to someone by E-mail Station Locations to someone by E-mail Share Alternative Fuels Data Center: Biodiesel Fueling Station Locations on Facebook Tweet about Alternative Fuels Data Center: Biodiesel Fueling Station Locations on Twitter Bookmark Alternative Fuels Data Center: Biodiesel Fueling Station Locations on Google Bookmark Alternative Fuels Data Center: Biodiesel Fueling Station Locations on Delicious Rank Alternative Fuels Data Center: Biodiesel Fueling Station Locations on Digg Find More places to share Alternative Fuels Data Center: Biodiesel Fueling Station Locations on AddThis.com... More in this section... Biodiesel Basics Benefits & Considerations Stations Locations Infrastructure Development Vehicles Laws & Incentives Biodiesel Fueling Station Locations Find biodiesel (B20 and above) fueling stations near an address or ZIP code

372

Location theory and the location of industry along an interstate highway  

E-Print Network (OSTI)

identified in theory will provide a basis for the "empirical" model or system of classification to be used in tabulating the response to the survey. Of particular interest is the theoretical development of the ms]or forces in plant location; i. e, , cost... identified in theory will provide a basis for the "empirical" model or system of classification to be used in tabulating the response to the survey. Of particular interest is the theoretical development of the ms]or forces in plant location; i. e, , cost...

Miller, James Patterson

2012-06-07T23:59:59.000Z

373

Advanced lightning location interferometer. Final report  

SciTech Connect

In January, 1994, New Mexico Institute for Mining and Technology (NM Tech) was commissioned by Los Alamos National Laboratories (LANL) to develop a three-axis interferometric lightning mapping system to be used in determining the source of certain frequency-dispersed pulse pairs which had been detected by spaceborne sensors. The existing NM Tech VHF Lightning Interferometer was a two axis system operating at 274 MHz with 6 MHz bandwidth. The third axis was to be added to refine estimates of the elevation angle to distant RF sources in that band. The system was to be initially deployed in support of an Air Force Technical Applications Center (AFTAC) effort planned for the Kennedy Space Center/Cape Canaveral AFS area in June-July of 1994. The project was, however, postponed until September of 1994. The interferometer was set up and operated at KSC near the Lightning Detection and Ranging (LDAR) central station. The initial setup was in two-axis configuration, and the third (vertical) axis was added at about mid-project. Though the storms were reduced in frequency and severity over what one would expect in mid-summer, several good data sets were obtained and delivered to AFTAC.

NONE

1995-05-25T23:59:59.000Z

374

PAD District / Refinery Location Total Atmospheric Distillation  

U.S. Energy Information Administration (EIA) Indexed Site

Operable Date of Last Operation Date Shutdown Table 11. New, Shutdown and Reactivated Refineries During 2012 a b REACTIVATED PAD District I 185,000 366,700 Monroe Energy LLC Trainer, PA 185,000 366,700 09/12 c SHUTDOWN PAD District I 80,000 47,000 ChevronUSA Inc Perth Amboy, NJ 80,000 47,000 03/08 07/12 PAD District III 16,800 19,500 Western Refining Southwest Inc Bloomfield, NM 16,800 19,500 12/09 11/12 PAD District VI 500,000 1,086,000 Hovensa LLC Kingshill, VI 500,000 1,086,000 02/12 02/12 a b bbl/cd=Barrels per calendar day. bbl/sd=Barrels per stream day. Sources: Energy Information Administration (EIA) Form EIA-810, "Monthly Refinery Report" and Form EIA-820, "Annual Refinery Report." c Formerly owned by ConocoPhillips Company.

375

Continuity of Operations Plan (COOP)  

NLE Websites -- All DOE Office Websites (Extended Search)

You are here: DOE-ID Home > COOP Continuity of Operations Plan (COOP) Call-In Number: 1-208-526-COOP (2667) or 1-877-DOE-DOE1 (1-877-363-3631) Wait for recording to start then Dial 382: If you are directed or forced to evacuate your current location to an alternate site, please contact us as soon as possible to advise us that you are safe and with a means of contacting you. This toll free or local number can be used by employees or their families to report their whereabouts or the whereabouts of another DOE-ID employee. Email Check-In: In addition to the call-in number, employees and families can report their status via a email check-in system. To access the email please click here. The email based check in system should only be used by DOE ID Employees.

376

Partial Discharge Location using Unsynchronized Radiometer Network for Condition Monitoring in HV Substations - A Proposed Approach  

Science Journals Connector (OSTI)

A location estimation system for online Partial Discharge (PD) detection is proposed as a low-cost approach to real-time condition monitoring, asset management and operation optimization in future smart grid. Some early progress in the development of subsystems (specifically the antenna, radiometer device, PD emulator and PD generator) for a proof-of-principle prototype system is described. The proposed PD Wireless Sensor Network (WSN) uses a novel approach to PD location which obviates the need for synchronization between sensors thereby improving scalability.

J M R de Souza Neto (IEEE member); E C T de Macedo; J S da Rocha Neto (IEEE senior member); E G da Costa; S A Bhatti; I A Glover

2012-01-01T23:59:59.000Z

377

Infrasound source location An automated method to estimate the location of infrasound sources  

E-Print Network (OSTI)

Waterstaat Delft University of Technology (DUT) Department of Earth Observation and Space Systems Acoustic Meteorologisch Instituut (KNMI) and three additional arrays located in Germany and France. The estimated source for a spherical earth. Extensive filtering is applied to clean the data from as much noise and signals from local

Evers, Läslo G.

378

Operations Research Analyst  

Energy.gov (U.S. Department of Energy (DOE))

This position may be located in the Office of Energy Analysis or the Office of Energy Statistics of EIA. This position is established to provide an expert analyst to perform mathematical,...

379

Alternative Fuels Data Center: Ethanol Fueling Station Locations  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Fueling Fueling Station Locations to someone by E-mail Share Alternative Fuels Data Center: Ethanol Fueling Station Locations on Facebook Tweet about Alternative Fuels Data Center: Ethanol Fueling Station Locations on Twitter Bookmark Alternative Fuels Data Center: Ethanol Fueling Station Locations on Google Bookmark Alternative Fuels Data Center: Ethanol Fueling Station Locations on Delicious Rank Alternative Fuels Data Center: Ethanol Fueling Station Locations on Digg Find More places to share Alternative Fuels Data Center: Ethanol Fueling Station Locations on AddThis.com... More in this section... Ethanol Basics Benefits & Considerations Stations Locations Infrastructure Development Vehicles Laws & Incentives Ethanol Fueling Station Locations Find ethanol (E85) fueling stations near an address or ZIP code or along a

380

Categorical Exclusion Determinations: Other Location | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Other Location Other Location Categorical Exclusion Determinations: Other Location Location Categorical Exclusion Determinations issued for actions in other locations. DOCUMENTS AVAILABLE FOR DOWNLOAD September 24, 2013 CX-010914: Categorical Exclusion Determination Pilot Testing of a Highly Efficient Pre-Combustion Sorbent-Based Carbon Capture System (SUMMARY Categorical Exclusion (CX)) CX(s) Applied: A9, A11, B3.6 Date: 09/24/2013 Location(s): Multiple States, China, Canada Offices(s): National Energy Technology Laboratory August 21, 2013 CX-010781: Categorical Exclusion Determination A Geomechanical Model for Gas Shales Based on Integration of Stress CX(s) Applied: A9, A11, B3.6 Date: 08/21/2013 Location(s): Pennsylvania Offices(s): National Energy Technology Laboratory August 16, 2013

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Baywind Energy Co operative Ltd | Open Energy Information  

Open Energy Info (EERE)

Baywind Energy Co operative Ltd Baywind Energy Co operative Ltd Jump to: navigation, search Name Baywind Energy Co-operative Ltd Place Barrow in Furness, Cumbria, United Kingdom Zip LA14 2PN Sector Renewable Energy, Wind energy Product A co-operative which owns 6 wind turbines in Cumbria and is seeking further opportunities to build renewable schemes. References Baywind Energy Co-operative Ltd[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Baywind Energy Co-operative Ltd is a company located in Barrow in Furness, Cumbria, United Kingdom . References ↑ "Baywind Energy Co-operative Ltd" Retrieved from "http://en.openei.org/w/index.php?title=Baywind_Energy_Co_operative_Ltd&oldid=34255

382

Building Operator Certification  

E-Print Network (OSTI)

programmed settings review ? Verify damper settings ? Check static pressure sensor calibration ? Review occupant complaint records and remedies ? Review established temperature set points HVAC Controls Operational Review ESL-KT-13-12-49 CATEE 2013: Clean... Operator Certification Energy Efficiency through Operator Training BOC Has Two Levels Level I: Building Systems Maintenance ? Two or more years experience (5 yrs avg) ? Outcome: Basic understanding of electrical, HVAC and lighting systems...

Lilley, D.

2013-01-01T23:59:59.000Z

383

Operations Cost Allocation Project  

NLE Websites -- All DOE Office Websites (Extended Search)

Operations Consolidation Project Operations Consolidation Project Operations Consolidation Project (OCP) Cost Allocation Presentation - September 20, 2011 OCP Cost Allocation Customer Presentation List of Acronyms OCP Cost Allocation Spreadsheets OCP Cost Allocation Customer Presentation - Questions and Answers - September 19 - 20, 2011 Additional Questions and Answers Customer Comments/Questions and Answers: Arizona Municipal Power Users Association Arizona Power Authority Central Arizona Project Colorado River Commission Colorado River Energy Distributors Association City of Gilbert, AZ Irrigation and Electrical Districts Association of Arizona Town of Marana, AZ City of Mesa, AZ Town of Wickenburg, AZ Western's Final Decision Regarding the Long-Term Cost Allocation Methodology for Operations Staff Costs

384

Business Operations Contacts  

Office of Energy Efficiency and Renewable Energy (EERE)

If you have a question for the Office of Business Operations, you can use this contact information to reach the office you're interested in:

385

Semicausal operations are semilocalizable  

E-Print Network (OSTI)

We prove a conjecture by DiVincenzo, which in the terminology of Preskill et al. [quant-ph/0102043] states that ``semicausal operations are semilocalizable''. That is, we show that any operation on the combined system of Alice and Bob, which does not allow Bob to send messages to Alice, can be represented as an operation by Alice, transmitting a quantum particle to Bob, and a local operation by Bob. The proof is based on the uniqueness of the Stinespring representation for a completely positive map. We sketch some of the problems in transferring these concepts to the context of relativistic quantum field theory.

Eggeling, T; Werner, R F

2002-01-01T23:59:59.000Z

386

Fermilab | Tevatron | Tevatron Operation  

NLE Websites -- All DOE Office Websites (Extended Search)

Operation Fermilab's Accelerator Complex Fermilab's Accelerator Complex has 10 accelerators. The Tevatron, which shuts down on Sept. 30, is one of those accelerators. The...

387

Pipeline Operations Program (Louisiana)  

Energy.gov (U.S. Department of Energy (DOE))

The Pipeline Operations Program regulates the construction, acquisition, abandonment and interconnection of natural gas pipelines, as well as, the transportation and use of natural gas supplies.

388

Richland Operations Office  

NLE Websites -- All DOE Office Websites (Extended Search)

treatment and the data should be available by the end of next week. * Status Conduct of Operations There have been several small incidents recently where observations of work...

389

Challenge # 3 ? Operational Issues  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Potential for a renewable heating oil substitution Challenge 3 - Operational Issues What are the most significant barriers to overcome in each market segment? Fernando Preto The...

390

Hanford Site air operating permit application  

SciTech Connect

The Clean Air Act Amendments of 1990, which amended the Federal Clean Air Act of 1977, required that the US Environmental Protection Agency develop a national Air Operating Permit Program, which in turn would require each state to develop an Air Operating Permit Program to identify all sources of ``regulated`` pollutants. Regulated pollutants include ``criteria`` pollutants (oxides of nitrogen, sulfur oxides, total suspended particulates, carbon monoxide, particulate matter greater than 10 micron, lead) plus 189 other ``Hazardous`` Air Pollutants. The Hanford Site, owned by the US Government and operated by the US Department of Energy, Richland Operations Office, is located in southcentral Washington State and covers 560 square miles of semi-arid shrub and grasslands located just north of the confluence of the Snake and Yakima Rivers with the Columbia River. This land, with restricted public access, provides a buffer for the smaller areas historically used for the production of nuclear materials, waste storage, and waste disposal. About 6 percent of the land area has been disturbed and is actively used. The Hanford Site Air Operating Permit Application consists of more than 1,100 sources and in excess of 300 emission points. Before January 1995, the maintenance and operations contractor and the environmental restoration contractor for the US Department of Energy completed an air emission inventory on the Hanford Site. The inventory has been entered into a database so that the sources and emission points can be tracked and updated information readily can be retrieved. The Hanford Site Air Operating Permit Application contains information current as of April 19, 1995.

NONE

1995-05-01T23:59:59.000Z

391

Alternative Fueling Station Locator - Mobile | Open Energy Information  

Open Energy Info (EERE)

Fueling Station Locator - Mobile Fueling Station Locator - Mobile Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Alternative Fueling Station Locator - Mobile Agency/Company /Organization: United States Department of Energy Partner: National Renewable Energy Laboratory Sector: Energy Focus Area: Transportation Phase: Evaluate Options, Prepare a Plan Resource Type: Online calculator User Interface: Mobile Device Website: www.afdc.energy.gov/afdc/locator/m/stations/ Web Application Link: www.afdc.energy.gov/afdc/locator/m/stations/ Cost: Free References: National Renewable Energy Laboratory Advanced Vehicles and Fuels Research: Data and Resources[1] Logo: Alternative Fueling Station Locator - Mobile Find fueling stations for your alternative fuel vehicle on-the-go with the

392

New standards for mechanical loading of HV air switches to reduce operating problems  

SciTech Connect

The problems inherent in dealing with mechanical forces upon switch terminals of high voltage air disconnect switches could be reduced substantially if proposed new mechanical loading standards were adopted, says Donald L. Lott of Siemens-Allis' Power Switching division. The result would be longer, more reliable service life. Simply stated, current standards do not take into consideration the bending moment exerted on the switch terminal pad, which can lead to improper alignment, misoperation and high stress on terminal pads. Lott says that mechanical loadings on terminal pads of HV substation air disconnect switches dictate the location of bus or cable support insulators and expansion connectors for rigid bus. While horizontal and vertical (weight of the conductor) forces are usually considered in design criteria, the bending moment caused by rigid bus sag is not taken into consideration when span lengths are long. Yet, he warns, this force often may be the most significant and can influence the location of the bus support insulators. The proposed standards would incorporate the effect of such bending moments.

Not Available

1986-02-01T23:59:59.000Z

393

Monitoring Environmental Recovery at Terminated Produced Water Discharge Sites in Coastal Louisiana Waters  

SciTech Connect

This report presents the results of a study of terminated produced water discharge sites in the coastal waters of Louisiana. Environmental recovery at the sites is documented by comparing pre-termination and post-termination (six months and one year) data. Produced water, sediments, and sediment interstitial water samples were analyzed for radionuclides, metals, and hydrocarbons. Benthic infauna were identified from samples collected in the vicinity of the discharge and reference sites. Radium isotope activities were determined in fish and crustacean samples. In addition, an environmental risk assessment is made on the basis of the concentrations of metals and hydrocarbons determined in the samples.

Continental Shelf Associates, Inc.

1999-08-16T23:59:59.000Z

394

Toledo Bend Project Joint Oper | Open Energy Information  

Open Energy Info (EERE)

Bend Project Joint Oper Bend Project Joint Oper Jump to: navigation, search Name Toledo Bend Project Joint Oper Place Texas Utility Id 19048 Utility Location Yes Ownership S NERC Location SERC NERC SERC Yes Operates Generating Plant Yes Activity Generation Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Toledo_Bend_Project_Joint_Oper&oldid=411678"

395

PAD District / Refinery Location Total Atmospheric Distillation  

U.S. Energy Information Administration (EIA) Indexed Site

of Last of Last Operation Date Shutdown Table 13. Refineries Permanently Shutdown By PAD District Between January 1, 1990 and January 1, 2013 PAD District I 542,450 GNC Energy Corp Greensboro, NC 3,000 0 a Primary Energy Corp Richmond, VA 6,100 0 a Saint Mary's Refining Co Saint Mary's, WV 4,000 4,480 02/93 03/93 Cibro Refining Albany, NY 41,850 27,000 07/93 09/93 Calumet Lubricants Co LP Rouseville, PA 12,800 26,820 03/00 06/00 Young Refining Corp. Douglasville, GA 5,400 0 07/04 07/04 Sunoco Inc Westville, NJ 145,000 263,000 11/09 02/10 Western Refining Yorktown Inc Yorktown, VA 66,300 182,600 09/10 12/11 Sunoco Inc Marcus Hook, PA 178,000 278,000 12/11 12/11 ChevronUSA Inc Perth Amboy, NJ 80,000 47,000 03/08 07/12 PAD District II 460,315 Coastal Refining & Mktg El Dorado, KS 0 20,000 b Intercoastal Energy Svcs

396

.JETEQUIPMENT &TOOLS OPERATOR'S MANUAL  

E-Print Network (OSTI)

.JETEQUIPMENT &TOOLS OPERATOR'S MANUAL JDP-14J/14M/17M/14JF/14 MF/17MF DRILL PRESS Stock No. .JET-6000 FAX[253] 939-8001 #12;OPERATINGINSTRUCTIONS Before operating the unit, please read this manual workpiece. 7. MAINTAIN TOOLS WITH CARE. Keep tools sharp and clean for the best and safest performance

Kleinfeld, David

397

An integrated technique for fault location and section identification in distribution systems  

Science Journals Connector (OSTI)

Abstract This paper proposes an integrated impedance and transient-based formulation for fault location in distribution systems. The technique uses an extended apparent impedance analysis in order to estimate the fault distance, taking into account the unbalanced operation, intermediate loads, laterals, and time-varying load profile of distribution systems. The fault distance information is used in calculating characteristic frequencies associated to each possible fault location. A transient analysis is proposed to evaluate the spectral content of the fault-generated traveling wave, thus identifying its most significant frequency components. Based on the timefrequency correlation it is possible to eliminate the multiple estimates obtained from the impedance-based method, thus resulting in a single fault location. Aiming to verify the application of the proposed methodology, simulations were carried out in the ATP/EMTP Software considering a real distribution feeder with 3472 buses.

D.S. Gazzana; G.D. Ferreira; A.S. Bretas; A.L. Bettiol; A. Carniato; L.F.N. Passos; A.H. Ferreira; J.E.M. Silva

2014-01-01T23:59:59.000Z

398

2014-08-28 Issuance: Energy Conservation Standards for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps; Notice of Proposed Rulemaking and Public Meeting  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register notice of proposed rulemaking and public meeting regarding energy conservation standards for packaged terminal air conditioners and packaged terminal heat pumps, as issued by the Assistant Secretary for Energy Efficiency and Renewable Energy on August 28, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

399

Locations of Smart Grid Demonstration and Large-Scale Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Locations of Smart Grid Demonstration and Large-Scale Energy Storage Projects Locations of Smart Grid Demonstration and Large-Scale Energy Storage Projects Map of the United States...

400

Property:News/PrimaryLocation | Open Energy Information  

Open Energy Info (EERE)

PrimaryLocation Jump to: navigation, search This is a property of type Page. Retrieved from "http:en.openei.orgwindex.php?titleProperty:NewsPrimaryLocation&oldid285888"...

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

File:VallesLocationMap.pdf | Open Energy Information  

Open Energy Info (EERE)

VallesLocationMap.pdf Jump to: navigation, search File File history File usage Metadata File:VallesLocationMap.pdf Size of this preview: 800 479 pixels. Full resolution (934...

402

On the Anonymity of Home/Work Location Pairs  

E-Print Network (OSTI)

On the Anonymity of Home/Work Location Pairs Philippe Golle and Kurt Partridge Palo Alto Research population is 1, 21 and 34,980, for locations known at the granularity of a census block, census track

Golle, Philippe

403

A Privacy Conscious Bluetooth Infrastructure for Location Aware Computing  

E-Print Network (OSTI)

We present a low cost and easily deployed infrastructure for location aware computing that is built using standard Bluetooth technologies and personal computers. Mobile devices are able to determine their location to ...

Huang, Albert

404

Energy Department Announces Student Teams, New Location for Solar...  

Energy Savers (EERE)

New Location for Solar Decathlon 2013 Energy Department Announces Student Teams, New Location for Solar Decathlon 2013 January 26, 2012 - 10:56am Addthis WASHINGTON, DC - At an...

405

Relative Location of Seismic Events Using Surface Waves  

Science Journals Connector (OSTI)

......The BOXCAR explosion at the Nevada Test Site was located with surface waves...activity in the Pahute Mesa area, Nevada Test Site, December 8, 1968-June 30...The BOXCAR explosion at the Nevada Test Site was located with surfacewavesusingboth......

David von Seggern

1972-04-01T23:59:59.000Z

406

Operability and Emissions from a Medium-Duty Fleet Operating...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Operability and Emissions from a Medium-Duty Fleet Operating with GTL Fuel and Catalyzed DPFs Operability and Emissions from a Medium-Duty Fleet Operating with GTL Fuel and...

407

Bear Creek: a case study in locating historic site remains in southeast Texas  

E-Print Network (OSTI)

, and Robert and Elaine Burden, for traipsing through the southeast Texas jungle and making it out alive. I further acknowledge the contributions of Phil Wise and Scott Garrett, lease holders and tour guides, and Kenneth Speckmaier for sharing the history... tasks may be time consuming and costly to a project, the more thorough the results, the smoother the survey operates. In terms of historic resources in particular, archival research may be the most crucial approach for locating historic sites especially...

Stahman, Andrea Renee

2006-04-12T23:59:59.000Z

408

Memorandum A. J. Rizzo, Chief TO : Operational Safety Branch  

Office of Legacy Management (LM)

j Memorandum A. J. Rizzo, Chief TO / : Operational Safety Branch Harold Glauberman, ?a FROM : Operational Safety Branch ' I DATE: September 30, 1966 REMOVAL OF CONTAMINATED EQUlPMEHT AT THE CANEL FACILITY SUBJECT: MI DDLETOWN, CONNECT I CUT' INTRODUCTION The decision to terminate AEC contract activities at the CANEL facility introduced the need to dispose of radioactively contaminated equipment and materials so as to permit release of the facilities. As a result, -' . the Operational Safety Branch, NY, was requested to perform thenecessary Health Physics surveillance and monitoring functions during the-disassembly, removal and packaging of the contaminated equipment. The actual removal and handling of contaminated equipment was performed by the' AEC.contractor,

409

On locatingdominating sets in infinite grids  

Science Journals Connector (OSTI)

Determining a malfunctioning component in a processor network gives the motivation for locatingdominating sets. It is shown that the smallest possible density of a locatingdominating set in the king grid equals 1/5 and in the hexagonal mesh 1/3. Moreover, we discuss a natural modification of locatingdominating sets.

Iiro Honkala; Tero Laihonen

2006-01-01T23:59:59.000Z

410

Improved approximation algorithms for a capacitated facility location problem  

E-Print Network (OSTI)

that ordinary randomized rounding rarely generates a feasible solution to the associated set covering problemImproved approximation algorithms for a capacitated facility location problem Fabi'an A. Chudak. There is a set of demand locations that require service from facilities; there is a set of locations at which

Keinan, Alon

411

Location-based Sponsored Search Advertising George Trimponias1  

E-Print Network (OSTI)

Location-based Sponsored Search Advertising George Trimponias1 , Ilaria Bartolini2 , Dimitris unprecedented opportunities for location-based advertising. In this work, we provide models and investigate the market for location-based sponsored search, where advertisers pay the search engine to be displayed

Papadias, Dimitris

412

KJC Operating Company | Open Energy Information  

Open Energy Info (EERE)

KJC Operating Company KJC Operating Company Jump to: navigation, search Name KJC Operating Company Place Boron, California Zip 93516 Sector Solar Product Developed solar thermal electricity generating plants, using Luz technology, in the Mojave Desert. Coordinates 34.99946°, -117.647884° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":34.99946,"lon":-117.647884,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

413

Laser Controlled Area Standard Operating Procedure (SOP)  

NLE Websites -- All DOE Office Websites (Extended Search)

3 3 001 Effective: Page 1 of 11/18/11 11 Subject: Laser Safety Program Documentation Bldg 703 E3/E4 3.1/2g03e011.doc 1 (02/2010) BROOKHAVEN NATIONAL LABORATORY LASER CONTROLLED AREA STANDARD OPERATING PROCEDURE (SOP) This document defines the safety management program for the laser system(s) listed below. All American National Standard Institute (ANSI) Hazard Class 3B and 4 laser systems must be documented, reviewed, and approved through use of this form. Each system must be reviewed annually. Modify the template for this document to fit your particular circumstance. System description: MOS laser curvature measurement system - Thin Film Deposition Lab Location: 703, E2/E4 LINE MANAGEMENT RESPONSIBILITIES The Owner/Operator(s) for this laser is/are listed below. The Owner/Operator is the Line Manager of the

414

An Integrated Approach to Building Operation  

NLE Websites -- All DOE Office Websites (Extended Search)

An Integrated Approach to Building Operation An Integrated Approach to Building Operation Speaker(s): David E. Claridge Date: April 16, 1999 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Richard Sextro Buildings systems have historically been over-sized to minimize contractor/designer call-backs. It is widely recognized that this over-sizing leads to excessive chiller and boiler cycling with an attendant reduction in efficiency. The same design approach routinely leads to reduced efficiencies throughout the building systems. The same mentality pervades the operation of building systems. This customarily increases utility costs by at least 20%. This presentation will present specific examples of the deleterious effects of the "more is better" approach by examining the impact of too much differential pressure across a control

415

California Independent System Operator | Open Energy Information  

Open Energy Info (EERE)

Operator Operator Jump to: navigation, search 200px Name California Independent System Operator Address California ISO P.O. Box 639014 Place Folsom, California Zip 95763-9014 Sector Services Phone number 916-351-4400 Website http://www.caiso.com Coordinates 38.68°, -121.18° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.68,"lon":-121.18,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

416

Laser Controlled Area Standard Operating Procedure (SOP)  

NLE Websites -- All DOE Office Websites (Extended Search)

32 32 004 Effective: Page 1 of 13 12/1/10 Subject: Laser Safety Program Documentation X20C 3.1/2g03e011.doc 1 (02/2010) BROOKHAVEN NATIONAL LABORATORY LASER CONTROLLED AREA STANDARD OPERATING PROCEDURE (SOP) This document defines the safety management program for the laser system(s) listed below. All American National Standard Institute (ANSI) Hazard Class 3B and 4 laser systems must be documented, reviewed, and approved through use of this form. Each system must be reviewed annually. Modify the template for this document to fit your particular circumstance. System description: Time-resolved light scattering Location: X20C Hutch LINE MANAGEMENT RESPONSIBILITIES The Owner/Operator(s) for this laser is/are listed below. The Owner/Operator is the Line Manager of the

417

Apparatus and method for maintaining low temperatures about an object at a remote location. [Patent application  

DOE Patents (OSTI)

The disclosure is directed to an apparatus and method for maintaining a body at cryogenic temperatures at a remote location such as down a borehole for an extended period of time. A housing contains a body comprising a material having a high specific heat at cryogenic temperatures such as between about 2 and 15 K. The body contains an orifice for containing an instrument or instruments operable at superconducting temperatures. The apparatus is precooled at the surface and lowered into a borehole to a desired depth, such as 2 to 3 miles. The instruments are operated, and the apparatus withdrawn, the material of the body maintaining the very low temperatures at which the instrument(s) operate for a sufficient period of time at the remote or downhole location. The material may comprise a rare earth compound, such as Gd/sub 2/O/sub 3/, Gd/sub 2/Se/sub 3/, Gd/sub 2/O/sub 2/S or GdAlO/sub 3/. Monoclinic and C-phase gadolinium oxides work well. A low temperature is maintainable at a remote location for several hours.

Steyert, W.A. Jr.; Overton, W.C. Jr.

1980-10-29T23:59:59.000Z

418

Apparatus and method for maintaining low temperatures about an object at a remote location  

DOE Patents (OSTI)

The disclosure is directed to an apparatus and method for maintaining a body at cryogenic temperatures at a remote location such as down a borehole for an extended period of time. A housing contains a body comprising a material having a high specific heat at cryogenic temperatures such as between about 2 and 15 K. The body contains an orifice for containing an instrument or instruments operable at superconducting temperatures. The apparatus is precooled at the surface and lowered into a borehole to a desired depth, such as 2 to 3 miles. The instruments are operated, and the apparatus withdrawn, the material of the body maintaining the very low temperatures at which the instrument(s) operate for a sufficient period of time at the remote or downhole location. The material may comprise a rare earth compound, such as Gd.sub.2 O.sub.3, Gd.sub.2 Se.sub.3, Gd.sub.2 O.sub.2 S or GdAlO.sub.3. Monoclinic and C-phase gadolinium oxides work well. A low temperature is maintainable at a remote location for several hours.

Steyert, Jr., William A. (Los Alamos, NM); Overton, Jr., William C. (Los Alamos, NM)

1982-01-01T23:59:59.000Z

419

Chromosomes and DNA of Mus: Terminal DNA synthetic sequences in three species  

Science Journals Connector (OSTI)

The DNA replication patterns of the terminal S phase of three species of Mus were analyzed by tritiated thymidine autoradiography. The centromeric heterochromatin of M. fulvidiventris is the latest component to f...

T. C. Hsu; Amara Markvong

420

Modeling of ECM Controlled Series Fan-powered VAV Terminal Units  

E-Print Network (OSTI)

Semi-empirical models for series fan-powered variable air volume terminal units (FPTUs) were developed based on models of the primary, plenum, fan airflow and the fan power consumption. The experimental setups and test procedures were developed...

Yin, Peng

2011-10-21T23:59:59.000Z

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Termination and complexity bounds for SAFE programs Salvador Lucas Ricardo Pe~na  

E-Print Network (OSTI)

Termination and complexity bounds for SAFE programs Salvador Lucas Ricardo Pe~na Dep. de Sistemas partially supported by the EU (FEDER) and the Spanish MEC, under grant TIN 2004-7943- C04. Salvador Lucas

Lucas, Salvador

422

E-Print Network 3.0 - amino-terminal dna binding Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

Nucleic Acid Copying using 2-amino-2, 3- Summary: -labeled-2-amino-terminated DNA primer, 0.5M template (5- GGGUp Up Up -3-primer binding site), 100mM MES... Figure S1. Acid...

423

A linear programming solution to the gate assignment problem at airport terminals  

E-Print Network (OSTI)

This research solves the flight-to-gate assignment problem at airports in such a way as to minimize, or at least reduce, walking distances for passengers inside terminals. Two solution methods are suggested. The first is ...

Mangoubi, Rami

1980-01-01T23:59:59.000Z

424

In-situ ellipsometry: Identification of surface terminations during GaN growth , T. Schmidtling1  

E-Print Network (OSTI)

1 In-situ ellipsometry: Identification of surface terminations during GaN growth C. Cobet1 , T SE, one is not limited to any special bulk or surface symmetry for optical characterisation. In PAMBE

Feenstra, Randall

425

E-Print Network 3.0 - amino-terminal pro-brain natriuretic Sample...  

NLE Websites -- All DOE Office Websites (Extended Search)

brain natriuretic Search Powered by Explorit Topic List Advanced Search Sample search results for: amino-terminal pro-brain natriuretic Page: << < 1 2 3 4 5 > >> 1 HEDS Discussion...

426

Simulation-based scheduling for parcel consolidation terminals: a comparison of iterative improvement and simulated annealing  

Science Journals Connector (OSTI)

This research explores the application of a simulation-based scheduling algorithm to generate unload schedules for processing feeder trailers in a parcel consolidation terminal. The study compares the performance of iterative improvement and simulated ...

Douglas L. McWilliams

2005-12-01T23:59:59.000Z

427

Bayesian-lopa methodology for risk assessment of an LNG importation terminal  

E-Print Network (OSTI)

instead. By the combination of Bayesian estimation and LOPA procedures, the Bayesian-LOPA methodology was developed and was applied to an LNG importation terminal. The found risk values were compared to the tolerable risk criteria to make risk decisions...

Yun, Geun-Woong

2009-05-15T23:59:59.000Z

428

N-Terminal HIV-1 Tat Nonapeptides as Inhibitors of Dipeptidyl Peptidase IV. Conformational Characterization  

Science Journals Connector (OSTI)

Compared to the N-terminal nonapeptide of the HIV-1 Tat protein as inhibitor of activity of DP ... is supposed to mediate the immunosuppressive effects of HIV-1 Tat, the Ile5 and Leu6 analogues showed strongly re...

Carmen Mrestani-Klaus; Annett Fengler

2002-01-01T23:59:59.000Z

429

The Accuracy of Radar Estimates of Ice Terminal Fall Speed from Vertically Pointing Doppler Radar Measurements  

Science Journals Connector (OSTI)

Doppler radar measurements at different frequencies (50 and 2835 MHz) are used to characterize the terminal fall speed of hydrometeors and the vertical air motion in tropical ice clouds and to evaluate statistical methods for retrieving these two ...

Alain Protat; Christopher R. Williams

2011-10-01T23:59:59.000Z

430

Energy, Shading and Daylighting Analysis for the Austin Bergstrom International Airport Terminal  

E-Print Network (OSTI)

Austin Airport included large glass areas for viewing arriving and departing planes, the sky, and the surrounding terrain. The glass was envisioned to provide quality natural lighting for the terminal during daylight hours in order to improve the quality...

Holder, L. M. III; Holder, L. M. IV

2002-01-01T23:59:59.000Z

431

Supporting Information: Ballistic transport and electrical spin signal amplification in a three-terminal  

E-Print Network (OSTI)

) where is the interface spin-asymmetry coefficient and can be determined for our devices from two-terminal spin valve measurements.1 For the channel lengths and bias voltages employed in #12;4 our devices

Yu, Edward T.

432

Cool heliosheath plasma and deceleration of the upstream solar wind at the termination shock  

Science Journals Connector (OSTI)

... The solar wind blows outward from the Sun and forms a bubble of ... wind blows outward from the Sun and forms a bubble of solar material in the interstellar medium. The termination shock occurs where the ...

John D. Richardson; Justin C. Kasper; Chi Wang; John W. Belcher; Alan J. Lazarus

2008-07-03T23:59:59.000Z

433

Properties of the termination shock observed by Voyager 2 and J. D. Richardson3  

E-Print Network (OSTI)

to the thermal ions downstream of the termination shock, probably due to the fact that most of the solar wind energy is transferred to the pickup ions. Citation: Li, H., C. Wang, and J. D. Richardson (2008

Richardson, John

434

Location-specific weather predictions for Sriharikota (13.72N, 80.22E) through numerical atmospheric models during satellite launch campaigns  

Science Journals Connector (OSTI)

Accurate knowledge of different meteorological parameters over a launch site is very crucial for efficient management of satellite launch operations. Local weather over the Indian satellite launch site located at...

D. Bala Subrahamanyam; Radhika Ramachandran; S. Indira Rani

2012-04-01T23:59:59.000Z

435

Spectrum of the volume integral operator of electromagnetic scattering  

E-Print Network (OSTI)

Spectrum of the volume integral operator of the three-dimensional electromagnetic scattering is analyzed. The operator has both continuous essential spectrum, which dominates at lower frequencies, and discrete eigenvalues, which spread out at higher ones. The explicit expression of the operator's symbol provides exact outline of the essential spectrum for any inhomogeneous anisotropic scatterer with Holder continuous constitutive parameters. Geometrical bounds on the location of discrete eigenvalues are derived for various physical scenarios. Numerical experiments demonstrate good agreement between the predicted spectrum of the operator and the eigenvalues of its discretized version.

Neil V. Budko; Alexander B. Samokhin

2005-05-04T23:59:59.000Z

436

Termination for a superconducting power transmission line including a horizontal cryogenic bushing  

DOE Patents (OSTI)

A termination for a superconducting power transmission line is disclosed which is comprised of a standard air entrance insulated vertical bushing with an elbow, a horizontal cryogenic bushing linking the pressurized cryogenic cable environment to the ambient temperature bushing and a stress cone which terminates the cable outer shield and transforms the large radial voltage gradient in the cable dielectric into a much lower radial voltage gradient in the high density helium coolant at the cold end of the cryogenic bushing.

Minati, Kurt F. (Northport, NY); Morgan, Gerry H. (Patchogue, NY); McNerney, Andrew J. (Shoreham, NY); Schauer, Felix (Upton, NY)

1984-01-01T23:59:59.000Z

437

Motor current signature analysis method for diagnosing motor operated devices  

DOE Patents (OSTI)

A motor current noise signature analysis method and apparatus for remotely monitoring the operating characteristics of an electric motor-operated device such as a motor-operated valve. Frequency domain signal analysis techniques are applied to a conditioned motor current signal to distinctly identify various operating parameters of the motor driven device from the motor current signature. The signature may be recorded and compared with subsequent signatures to detect operating abnormalities and degradation of the device. This diagnostic method does not require special equipment to be installed on the motor-operated device, and the current sensing may be performed at remote control locations, e.g., where the motor-operated devices are used in accessible or hostile environments.

Haynes, Howard D. (Kingston, TN); Eissenberg, David M. (Oak Ridge, TN)

1990-01-01T23:59:59.000Z

438

Site Location of Development Act (Maine) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Location of Development Act (Maine) Location of Development Act (Maine) Site Location of Development Act (Maine) < Back Eligibility Agricultural Commercial Construction Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Maine Program Type Siting and Permitting Provider Department of Environmental Protection The Site Location of Development Act regulates the locations chosen for

439

Building Technologies Office: DOE Challenge Home Partner Locator  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Building Technologies Office Search Building Technologies Office Search Search Help Building Technologies Office HOME ABOUT EMERGING TECHNOLOGIES RESIDENTIAL BUILDINGS COMMERCIAL BUILDINGS APPLIANCE & EQUIPMENT STANDARDS BUILDING ENERGY CODES EERE » Building Technologies Office » Residential Buildings Share this resource Send a link to Building Technologies Office: DOE Challenge Home Partner Locator to someone by E-mail Share Building Technologies Office: DOE Challenge Home Partner Locator on Facebook Tweet about Building Technologies Office: DOE Challenge Home Partner Locator on Twitter Bookmark Building Technologies Office: DOE Challenge Home Partner Locator on Google Bookmark Building Technologies Office: DOE Challenge Home Partner Locator on Delicious Rank Building Technologies Office: DOE Challenge Home Partner

440

Alternative Fuels Data Center: Natural Gas Fueling Station Locations  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Natural Gas Natural Gas Printable Version Share this resource Send a link to Alternative Fuels Data Center: Natural Gas Fueling Station Locations to someone by E-mail Share Alternative Fuels Data Center: Natural Gas Fueling Station Locations on Facebook Tweet about Alternative Fuels Data Center: Natural Gas Fueling Station Locations on Twitter Bookmark Alternative Fuels Data Center: Natural Gas Fueling Station Locations on Google Bookmark Alternative Fuels Data Center: Natural Gas Fueling Station Locations on Delicious Rank Alternative Fuels Data Center: Natural Gas Fueling Station Locations on Digg Find More places to share Alternative Fuels Data Center: Natural Gas Fueling Station Locations on AddThis.com... More in this section... Natural Gas Basics Benefits & Considerations

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Operations Research Analysts  

U.S. Energy Information Administration (EIA) Indexed Site

Operations Research Analysts Operations Research Analysts The U.S. Energy Information Administration (EIA) within the Department of Energy has forged a world-class information program that stresses quality, teamwork, and employee growth. In support of our program, we offer a variety of profes- sional positions, including the Operations Research Analyst, whose work is associated with the development and main- tenance of energy modeling systems. Responsibilities: Operations Research Analysts perform or participate in one or more of the following important functions: * Develop, design, perform, and document a broad range of analyses and studies involving current and projected energy pricing, production, supply, and distribution, and consumption * Using computer programming skills and knowledge of energy industries and markets, designs and develops math-

442

Field Operations Program  

NLE Websites -- All DOE Office Websites (Extended Search)

688 688 May 1999 Field Operations Program Activities Status Report Fiscal Years 1997 through mid-1999 J. E. Francfort D. V. O'Hara L. A. Slezak DOE/ID-10688 Field Operations Program Activities Status Report Fiscal Years 1997 through mid-1999 J. E. Francfort 1 D. V. O'Hara 2 L. A. Slezak 2 Published May 1999 Idaho National Engineering and Environmental Laboratory Automotive Systems and Technology Department Lockheed Martin Idaho Technologies Company Idaho Falls, Idaho 83415 Prepared for the U.S. Department of Energy Idaho Operations Office 1 INEEL/Lockheed Martin Idaho Technologies Co. 2 U.S. Department of Energy iii EXECUTIVE SUMMARY The Field Operations Program is an electric vehicle testing and evaluation program sponsored by U.S. Department of Energy and managed by the Idaho National Engineering and Environmental

443

Operational Area Monitoring Plan  

Office of Legacy Management (LM)

' ' SECTION 11.7B Operational Area Monitoring Plan for the Long -Term H yd rol og ical M o n i to ri ng - Program Off The Nevada Test Site S . C. Black Reynolds Electrical & Engineering, Co. and W. G. Phillips, G. G. Martin, D. J. Chaloud, C. A. Fontana, and 0. G. Easterly Environmental Monitoring Systems Laboratory U. S. Environmental Protection Agency October 23, 1991 FOREWORD This is one of a series of Operational Area Monitoring Plans that comprise the overall Environmental Monitoring Plan for the DOE Field Office, Nevada (DOEINV) nuclear and non- nuclear testing activities associated with the Nevada Test Site (NTS). These Operational Area Monitoring Plans are prepared by various DOE support contractors, NTS user organizations, and federal or state agencies supporting DOE NTS operations. These plans and the parent

444

Operations Research Analyst  

Energy.gov (U.S. Department of Energy (DOE))

A successful candidate in this position will serve as an Operations Research Analyst assigned to CEPE, in Washington, DC and is responsible for conducting independent cost and schedule estimates of...

445

Oak Ridge Operations.  

Office of Legacy Management (LM)

4s - 22 Department of Energy Oak Ridge Operations. SI9J>liB P.O. Box 2001 Oak Ridge. Tennessee 37831-8723 October 21, 1994 Mr. Charles A. Duritsa Regional Director...

446

Operating Oak Ridge's "Calutrons"  

NLE Websites -- All DOE Office Websites (Extended Search)

RIDGE'S CALUTRONS: In this oral history, Theodore Rockwell talks about the Y-12 plant at Oak Ridge where the calutrons were operated by young women, many just out of high school....

447

Oak Ridge Operations YTO  

Office of Legacy Management (LM)

ed States Government Department of Energy Oak Ridge Operations YTO r , , EM-93:Hartman I - CATEGORICAL EXCLUSION (CX) DETERMINATION - RMOVAL ACTION AT M E SPRINGDALE r SITE I -a...

448

Protection Program Operations  

Directives, Delegations, and Requirements

This Order establishes requirements for the management and operation of the Department of Energy (DOE) Federal Protective Forces (FPF), Contractor Protective Forces (CPF), and the Physical Security of property and personnel under the cognizance of DOE.

2014-10-14T23:59:59.000Z

449

Operations Security Program  

Directives, Delegations, and Requirements

To establish policies, responsibilities and authorities for implementing and sustaining the Department of Energy (DOE) Operations Security (OPSEC) Program. Cancels DOE O 5632.3B. Canceled by DOE O 471.2 of 9-28-1995.

1992-04-30T23:59:59.000Z

450

Operations and Maintenance  

Energy.gov (U.S. Department of Energy (DOE))

Lower operations and maintenance (O&M) costs are critical to reducing a solar system's lifecycle cost of ownership. O&M costs are influenced by up-front investments in design, engineering,...

451

Operating plan FY 1998  

SciTech Connect

This document is the first edition of Argonne`s new Operating Plan. The Operating Plan complements the strategic planning in the Laboratory`s Institutional Plan by focusing on activities that are being pursued in the immediate fiscal year, FY 1998. It reflects planning that has been done to date, and it will serve in the future as a resource and a benchmark for understanding the Laboratory`s performance. The heart of the Institutional Plan is the set of major research initiatives that the Laboratory is proposing to implement in future years. In contrast, this Operating Plan focuses on Argonne`s ongoing R&D programs, along with cost-saving measures and other improvements being implemented in Laboratory support operations.

NONE

1997-10-01T23:59:59.000Z

452

CH Packaging Operations Manual  

SciTech Connect

This procedure provides instructions for assembling the CH Packaging Drum payload assembly, Standard Waste Box (SWB) assembly, Abnormal Operations and ICV and OCV Preshipment Leakage Rate Tests on the packaging seals, using a nondestructive Helium (He) Leak Test.

Washington TRU Solutions LLC

2005-06-13T23:59:59.000Z

453

Cogeneration Operational Issues  

E-Print Network (OSTI)

important, however, are the operational Issues which impact the utility and the cogenerator. This paper addresses the utility perspective in regard to possible impact of cogeneration systems on utility service to other customer, safety and substation...

Williams, M.

454

Idaho Operations Office  

NLE Websites -- All DOE Office Websites (Extended Search)

adverse impacts 40 CFR 1508.27 (b)(l): The selected action establishes a capability to conduct outdoor linac operations at higher power and greater standoff distances. The SOX...

455

Crane Operation Training  

NLE Websites -- All DOE Office Websites (Extended Search)

remove power from the crane and inform the facility management or CAMD safety. Place a lockout tag on the remote control unit. All CAMD crane operations are conducted using the...

456

Plant Operations Executive Director  

E-Print Network (OSTI)

Campus North Campus Recycling Operations Materials Human Resources Payroll Misc Svs Special Projects Planning Spray Shop Glass Shop Upholstery Shop Plant IT Painting Services G. Weincouff Human Resources Business Services Estimating Shutdown Coordination Scheduling L. Rastique Human Resources 67398 M

Awtar, Shorya

457

Corporate Operating Experience Program  

Energy.gov (U.S. Department of Energy (DOE))

The DOE Corporate Operating Experience Program helps to prevent the recurrence of significant adverse events/trends by sharing performance information, lessons learned and good practices across the DOE complex.

458

Essays on Retail Operations  

E-Print Network (OSTI)

-fraction and all-or-none inspection. We further perform a case study to identify deficiencies of store operating practices given different risk preferences. Our findings provide practical guidelines for managers to design cost-efficient inspection policy...

Chuang, Hao-Chun

2013-03-12T23:59:59.000Z

459

Transmission and Storage Operations  

Energy Savers (EERE)

to see minimal to none in static or dynamic mode) - Rates are dependent on size, mechanical wear and operating pressures * PM * PdM 5 Methane Release Reduction Can the gas be...

460

Development of Operation System  

Science Journals Connector (OSTI)

We are gradually developing a total hospital information system known as GUNMAS (Gunma University Network for Medical-Hospital- Information Archiving System). an operation system is also being developed as part o...

Seiji Kato M.D.; Yasuharu Kitani M.D.

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Pipeline operation and safety  

SciTech Connect

Safety is central to the prosperity of the pipeline industry and the need to maintain high standards of the safety at all times is of paramount importance. Therefore, a primary concern of pipeline operator is adequate supervision and the control of the operation of pipelines. Clearly defined codes of practice, standards and maintenance schedules are necessary if protection is to be afforded to the pipeline system employees, the public at large, and the environment.

Tadors, M.K. [Petroleum Pipelines Co., Cairo (Egypt)

1996-12-31T23:59:59.000Z

462

Assessment of the 296-S-21 Stack Sampling Probe Location  

SciTech Connect

Tests were performed to assess the suitability of the location of the air sampling probe on the 296-S-21 stack according to the criteria of ANSI N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities. Pacific Northwest National Laboratory conducted most tests on a 3.67:1 scale model of the stack. CH2MHill also performed some limited confirmatory tests on the actual stack. The tests assessed the capability of the air-monitoring probe to extract a sample representative of the effluent stream. The tests were conducted for the practical combinations of operating fans and addressed: (1) Angular Flow--The purpose is to determine whether the velocity vector is aligned with the sampling nozzle. The average yaw angle relative to the nozzle axis should not be more than 20. The measured values ranged from 5 to 11 degrees on the scale model and 10 to 12 degrees on the actual stack. (2) Uniform Air Velocity--The gas momentum across the stack cross section where the sample is extracted should be well mixed or uniform. The uniformity is expressed as the variability of the measurements about the mean, the coefficient of variance (COV). The lower the COV value, the more uniform the velocity. The acceptance criterion is that the COV of the air velocity must be ?20% across the center two-thirds of the area of the stack. At the location simulating the sampling probe, the measured values ranged form 4 to 11%, which are within the criterion. To confirm the validity of the scale model results, air velocity uniformity measurements were made both on the actual stack and on the scale model at the test ports 1.5 stack diameters upstream of the sampling probe. The results ranged from 6 to 8% COV on the actual stack and 10 to 13% COV on the scale model. The average difference for the eight runs was 4.8% COV, which is within the validation criterion. The fact that the scale model results were slightly higher than the actual stack suggests that the other test results on the scale model are conservative relative to the actual stack. (3) Uniform Concentration of Tracer Gases--A uniform contaminant concentration in the sampling plane enables the extraction of samples that represent the true concentration. This was first tested using a tracer gas to represent gaseous effluents. The fan is a good mixer, so injecting the tracer downstream of the fans provides worst-case results. The acceptance criteria are that (1) the COV of the measured tracer gas concentration is ?20% across the center two-thirds of the sampling plane and (2) at no point in the sampling plane does the concentration vary from the mean by >30%. The results on the scale model at the point simulating the sampling probe ranged from 0.3 to 6 %COV, and the maximum single point deviation from the mean was -10%. (4) Uniform Concentration of Tracer Particles--Uniformity in contaminant concentration at the sampling probe was further demonstrated using tracer particles large enough to exhibit inertial effects. Particles of 10-?m aerodynamic diameter were used. The acceptance criterion is that the COV of particle concentration is ?20% across the center two-thirds of the sampling plane. The scale model results ranged form 2 to 9%. Based on these tests, the location of the air sampling probe on the 296-S-21 stack meets the requirements of the ANSI/HPS N13.1-1999 standard.

Glissmeyer, John A.

2006-09-08T23:59:59.000Z

463

Energy Department Management and Operations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Department Management and Operations Energy Department Management and Operations Energy Department Management and Operations January 17, 2013 - 12:00pm Addthis The Energy Departments headquarters is located at the Forrestal Building in Washington, DC. | Energy Department photo, credit Quentin Kruger. The Energy Departments headquarters is located at the Forrestal Building in Washington, DC. | Energy Department photo, credit Quentin Kruger. Melvin G. Williams, Jr. Melvin G. Williams, Jr. Former Associate Deputy Secretary Our main effort is for a sustained commitment to achieve management and operational excellence, which is identified as one of the four strategic goals for the Department. We are focused on the safe, secure, efficient, and effective mission execution, and results/actions are tracked via 52 Measures of Performance

464

Midwest Independent Transmission System Operator Smart Grid Project | Open  

Open Energy Info (EERE)

Operator Smart Grid Project Operator Smart Grid Project Jump to: navigation, search Project Lead Midwest Independent Transmission System Operator Country United States Headquarters Location Carmel, Indiana Additional Benefit Places Iowa, Illinois, Michigan, Minnesota, Missouri, Montana, North Dakota, Ohio, Pennsylvania, South Dakota, Wisconsin Recovery Act Funding $17,271,738.00 Total Project Value $34,543,476.00 Coverage Area Coverage Map: Midwest Independent Transmission System Operator Smart Grid Project Coordinates 39.978371°, -86.1180435° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

465

KCP&L Greater Missouri Operations | Open Energy Information  

Open Energy Info (EERE)

Operations Operations Jump to: navigation, search Name KCP&L Greater Missouri Operations Place Missouri Utility Id 12698 Utility Location Yes Ownership I NERC Location SPP, WECC NERC SPP Yes RTO SPP Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Large General Service-Secondary Commercial Large Power Service-Secondary Commercial

466

Integral cesium reservoir: Design and transient operation  

SciTech Connect

An electrically heated thermionic converter has been designed built and successfully tested in air (Homer et.al., 1995). One of the unique features of this converter was an integral cesium reservoir thermally coupled to the emitter. The reservoir consisted of fifteen cesiated graphite pins located in pockets situated in the emitter lead with thermal coupling to the emitter, collector and the emitter terminal; there were no auxiliary electric heaters on the reservoir. Test results are described for conditions in which the input thermal power to the converter was ramped up and down between 50% and 100% of full power in times as short as 50 sec, with data acquisition occurring every 12 sec. During the ramps the emitter and collector temperature profiles. the reservoir temperature and the electric output into a fixed load resistor are reported. The converter responded promptly to the power ramps without excessive overshoot and with no tendency to develop instabilities. This is the rust demonstration of the performance of a cesium-graphite integral reservoir in a fast transient

Smith, J.N. Jr.; Horner, M.H.; Begg, L.L. [General Atomics, San Diego, CA (United States); Wrobleski, W.J. [Westinghouse Electric Corp., West Mifflin, PA (United States). Bettis Atomic Power Lab.

1995-01-01T23:59:59.000Z

467

Alternative Fueling Station Locator App Provides Info at Your Fingertips |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alternative Fueling Station Locator App Provides Info at Your Alternative Fueling Station Locator App Provides Info at Your Fingertips Alternative Fueling Station Locator App Provides Info at Your Fingertips November 15, 2013 - 10:12am Addthis The Alternative Fueling Station Locator iPhone app helps you find fueling stations that offer electricity, natural gas, biodiesel, E85, propane, or hydrogen. | Energy Department The Alternative Fueling Station Locator iPhone app helps you find fueling stations that offer electricity, natural gas, biodiesel, E85, propane, or hydrogen. | Energy Department Shannon Brescher Shea Communications Manager, Clean Cities Program Smartphone users are familiar with the prompt, "Would you like this site to use your current location?" If you're looking for somewhere to fuel your

468

Establish Building Locations for Greenhouse Gas Mitigation | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Establish Building Locations for Greenhouse Gas Mitigation Establish Building Locations for Greenhouse Gas Mitigation Establish Building Locations for Greenhouse Gas Mitigation October 7, 2013 - 10:53am Addthis YOU ARE HERE Step 2 After estimating greenhouse gas (GHG) emissions by building type, building location is an important consideration in evaluating the relevance of energy-saving strategies due to variations in heating and cooling needs, and the GHG reduction potential due to variability of emissions factors across regions of the grid. If site-level energy use estimates are available for each of the program's key building types, the program can identify building locations with the greatest emission reduction potential by using the benchmarking approach. Locations with the worst energy performance relative to the benchmark are

469

Alternative Fueling Station Locator App Provides Info at Your Fingertips |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alternative Fueling Station Locator App Provides Info at Your Alternative Fueling Station Locator App Provides Info at Your Fingertips Alternative Fueling Station Locator App Provides Info at Your Fingertips November 15, 2013 - 10:12am Addthis The Alternative Fueling Station Locator iPhone app helps you find fueling stations that offer electricity, natural gas, biodiesel, E85, propane, or hydrogen. | Energy Department The Alternative Fueling Station Locator iPhone app helps you find fueling stations that offer electricity, natural gas, biodiesel, E85, propane, or hydrogen. | Energy Department Shannon Brescher Shea Communications Manager, Clean Cities Program Smartphone users are familiar with the prompt, "Would you like this site to use your current location?" If you're looking for somewhere to fuel your

470

General Laser Control Measures Operating instructions for a specific laser are found in the manual for that laser.  

E-Print Network (OSTI)

General Laser Control Measures Operating instructions for a specific laser are found in the manual for that laser. There are several procedures that will reduce the potential for exposure to laser beams. 1. The beam from Class IIIB and Class IV lasers should be terminated in highly absorbent, non specular

Huennekens, John

471

Operations Information for Studies  

NLE Websites -- All DOE Office Websites (Extended Search)

Operations Information for Studies Operations Information for Studies This page contains historical information about hydropower operations. Reclamation UC Region 24-Month Studies FY2009 Load Information (pdf) SLIP total customer loads for Fiscal Year 2009 (Oct, 2008-Sept, 2009) FY2010 Load Information (pdf) SLIP total customer loads for Fiscal Year 2010 (Oct, 2009-Sept, 2010) FY2011 Load Information (pdf) SLIP total customer loads for Fiscal Year 2011 (Oct, 2010-Sept, 2011) FY2012 Load Information (pdf) SLIP total customer loads for Fiscal Year 2012 (Oct, 2011-Sept, 2012) FY2013 Load Information (pdf) SLIP total customer loads for Fiscal Year 2013 (Oct, 2012-Sept, 2013) CRSP Projected Power Releases From USBR (Excel) The most recent file of projected future power releases from CRSP Dams, median projection

472

Storage Ring Operation Modes  

NLE Websites -- All DOE Office Websites (Extended Search)

Longitudinal bunch profile and Up: APS Storage Ring Parameters Longitudinal bunch profile and Up: APS Storage Ring Parameters Previous: Source Parameter Table Storage Ring Operation Modes Standard Operating Mode, top-up Fill pattern: 102 mA in 24 singlets (single bunches) with a nominal current of 4.25 mA and a spacing of 153 nanoseconds between singlets. Lattice configuration: Low emittance lattice with effective emittance of 3.1 nm-rad and coupling of 1%. Bunch length (rms): 33.5 ps. Refill schedule: Continuous top-up with single injection pulses occurring at a minimum of two minute intervals, or a multiple of two minute intervals. Special Operating Mode - 324 bunches, non top-up Fill pattern: 102 mA in 324 uniformly spaced singlets with a nominal single bunch current of 0.31 mA and a spacing of 11.37 nanoseconds between singlets.

473

Automated detection and location of indications in eddy current signals  

DOE Patents (OSTI)

A computer implemented information extraction process that locates and identifies eddy current signal features in digital point-ordered signals, signals representing data from inspection of test materials, by enhancing the signal features relative to signal noise, detecting features of the signals, verifying the location of the signal features that can be known in advance, and outputting information about the identity and location of all detected signal features.

Brudnoy, David M. (Albany, NY); Oppenlander, Jane E. (Burnt Hills, NY); Levy, Arthur J. (Schenectady, NY)

2000-01-01T23:59:59.000Z

474

Safe Chain Saw Operation.  

E-Print Network (OSTI)

Z TA24S.7 8873 NO.1409 B-1409 SAFE CHAIN SAW OPERATION Gary S. Nelson* A chain saw is a portable power cutting machine. Used properly, it will trim or cut down trees, clear land or cut fireplace wood. Improperly used, a chain saw can... ground level , losing balance, shifting chain saw weight while cutting at or above waist level or ex periencing chain saw kickback. Often, loss of balance causes an operator to reach into the running saw blade as he grabs to steady himself. Other...

Nelson, Gary S.

1982-01-01T23:59:59.000Z

475

Determining Optimal Locations for New Wind Energy Development in Iowa.  

E-Print Network (OSTI)

??The purpose of this research is to generate the most accurate model possible for predicting locations most suitable for new wind energy development using a (more)

Mann, David

2011-01-01T23:59:59.000Z

476

GIS and Location Theory Based Bioenergy Systems Planning.  

E-Print Network (OSTI)

??This research is concerned with bioenergy systems planning and optimization modelling in the context of locating biomass power plants and allocating available biomass feedstock to (more)

Dong, Jingyuan

2008-01-01T23:59:59.000Z

477

Policy-aware sender anonymity in Location-based services  

E-Print Network (OSTI)

from attackers who (via hacking or subpoenas) gain access toagainst attackers who, via hacking or subpoenas, gain accessthe location database D 1 (via hacking or subpoena) and is

Vyas, Avinash

2011-01-01T23:59:59.000Z

478

Colorado CRS 29-20-108, Location, Construction, or Improvement...  

Open Energy Info (EERE)

Location, Construction, or Improvement of Major Electrical or Natural Gas Facilities Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document-...

479

Research Site Locations for Current EERE Postdoctoral Awards...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

More Documents & Publications Research Site Locations for Current and Former EERE Postdoctoral Awards EERE: VTO - Red Leaf PNG Image EERE: VTO - Hybrid Bus PNG Image...

480

Open Location-Oriented Services for the Web  

E-Print Network (OSTI)

point of a Service Oriented Architecture (SOA). Technically,the Web Service Oriented Architecture (SOA) ArchitecturalLocation-Oriented Services for the Web architecture based on

Wilde, Erik

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "terminal operator location" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

The Value of Flexibility in Robust Location-Transportation Problem  

E-Print Network (OSTI)

Nov 25, 2014 ... Abstract: Facility location decisions play a critical role in transportation planning. In fact, it has recently become essential to study how such...

Amir Ardestani-Jaafari

2014-11-25T23:59:59.000Z

482

Nanotechnology enterprise in the United States: structure and location.  

E-Print Network (OSTI)

??This thesis investigates the structure and location of the nanotechnology enterprise in the United States. Nanotechnology merits focus because of the high degree of innovative (more)

Bhaskarabhatla, Ajay Sivaram

2006-01-01T23:59:59.000Z

483

p-facility Huff location problem on networks ?  

E-Print Network (OSTI)

sidering the location of two competing facilities on a linear market. ... This perturbs how the market is shared, since the new facilities will ..... Transactions in.

2014-10-30T23:59:59.000Z

484

Reliability Models for Facility Location: The Expected Failure Cost ...  

E-Print Network (OSTI)

Reliability Models for Facility Location: The Expected Failure Cost Case. Lawrence V. Snyder (larry.snyder ***at*** lehigh.edu) Mark S. Daskin (m-daskin *

Lawrence V. Snyder

485

Alternative Fueling Station Locator App Provides Info at Your...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fueling Station Locator website. It provides information on more than 15,000 public and private alternative fueling stations throughout the United States. The app lists where...

486

Optimization Online - THE MULTIFACILITY LOCATION PROBLEM ...  

E-Print Network (OSTI)

Abstract: A generalized Weiszfeld method is proposed for the multifacility location ... Category 1: Applications -- OR and Management Sciences (Other ).

Cem Iyigun

487

Announcement of Change in Public Meeting Location for the Northern...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Announcement of Change in Public Meeting Location for the Northern Pass Transmission Line Project Published in the Federal Register Announcement of Change in Public Meeting...

488

Fault Location and Incipient Fault Detection in Distribution Cables.  

E-Print Network (OSTI)

??A set of fault location algorithms for underground medium voltage cables, two incipient fault detection schemes for distribution cables and a state estimation method for (more)

Xu, Zhihan

2011-01-01T23:59:59.000Z

489

Locating Climate Insecurity: Where Are the Most Vulnerable Places...  

Open Energy Info (EERE)

Insecurity: Where Are the Most Vulnerable Places in Africa? Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Locating Climate Insecurity: Where Are the Most Vulnerable...

490

An Aggressive Reduction Scheme for the Simple Plant Location ...  

E-Print Network (OSTI)

We used routines from the Callable Library of IBM CPLEX version. 12.1 to solve ..... [23] M. Sun (2006) Solving the uncapacitated facility location problem using.

2011-11-26T23:59:59.000Z

491

Updated July 2009 Operations Organization  

E-Print Network (OSTI)

All-Hands, Brown Bags, and COO Open-Door sessions Ongoing Conduct Operations Employee Climate SurveysOperations Strategic Plan Updated July 2009 #12;Operations Organization Chief Operating Officer deliver exceptional operational services in support of the scientific mission of Berkeley Lab. goals

Eisen, Michael

492

Biosecurity Practices for Dairy Operations  

E-Print Network (OSTI)

DiseaseSpreads Diseasespreadsdirectly?fromaninfectedanimaltoasus- ceptibleanimal?andindirectlyfromcontactwithcontami- natedobjects,equipment,insectsorpeople(Table1). Pathogensinfectthroughfiveprimaryroutes: ?Inhalation...:Commondiseasesindairycattle. More information is available at http://aevm.tamu.edu Disease Methodofspreading Commonsymptoms Anthrax Oral, inhalation, blood Staggering, trembling, collapse, terminal convulsions, bloody discharge Bovine brucellosis Oral, reproduction Abortions...

Jordan, Ellen R.; Dement, Angela; Faries Jr., Floron C.

2008-10-06T23:59:59.000Z

493

Electronic states of NO{sub 2}-exposed H-terminated diamond/Al{sub 2}O{sub 3} heterointerface studied by synchrotron radiation photoemission and X-ray absorption spectroscopy  

SciTech Connect

The energy band-lineup and the electronic structure of NO{sub 2}-exposed H-terminated diamond/Al{sub 2}O{sub 3} heterointerface have been investigated by synchrotron radiation photoemission and x-ray absorption near-edge structure (XANES) measurements. It is found that the energy band-lineup is stagger-type, so-called type-II, with its valence band discontinuity of as high as 3.9?eV and its conduction band discontinuity of 2.7?eV. The valence band maximum of the H-terminated diamond surface is positioned at Fermi level as a result of high-density hole accumulation on the diamond side. The XANES measurement has shown that the oxygen-derived interface state locates at about 13?eV above the Fermi level.

Takahashi, Kazutoshi; Imamura, Masaki [Synchrotron Light Application Center, Saga University, Saga 840-8502 (Japan); Hirama, Kazuyuki [NTT Basic Research Laboratories, NTT Corporation, Atsugi 243-0198 (Japan); Kasu, Makoto [Department of Electrical and Electronic Engineering, Saga University, Saga 840-8502 (Japan)

2014-02-17T23:59:59.000Z

494

Hoyte Phifer Facilities Operations  

E-Print Network (OSTI)

battery operated clocks in offices. #12;#12;·Last year, UNCG produced over 1973 tons of solid waste. · 1. , corner of Highland Ave. and Oakland ­ red brick building #12;#12; "All State agencies, universities, and community colleges that have State-owned vehicle fleets shall develop and implement plans to improve

Saidak, Filip

495

Concept of Operations: Essence  

SciTech Connect

This concept of operations is designed to give the reader a brief overview of the National Rural Electric Cooperative Associations Essence project and a description of the Essence device design. The data collected by the device, how the data are used, and how the data are protected are also discussed in this document.

Hutton, William J.

2014-04-01T23:59:59.000Z

496

Conduct of Operations  

Directives, Delegations, and Requirements

This Order defines the requirements for establishing and implementing Conduct of Operations Programs at Department of Energy (DOE), including National Nuclear Security Administration (NNSA), facilities and projects. Cancels DOE O 5480.19. Admin Chg 2, dated 12-3-14, cancels Admin Chg 1.

2010-06-29T23:59:59.000Z

497

RUNWAY OPERATIONAL QUALITY ASSURANCE  

E-Print Network (OSTI)

RUNWAY OPERATIONAL QUALITY ASSURANCE MELANIE BAKER, DARIC MEGERSA & ALFONSO PANLILIO Sponsors: Dr Vortex Separation Rule, for a homogeneous fleet mix, is determined by the time between arriving aircraft Occupancy (SRO) rule, for a non- homogeneous fleet mix, MTC= 3600/ [ROT] [ROT]= = i (pi *ROTi) ROT (in sec

498

Sensitivity of forced air distribution system efficiency to climate, duct location, air leakage and insulation  

E-Print Network (OSTI)

Location, Air Leakage and Insulation Iain S. Walker Energy4 Duct Insulation, Location and Leakageinsulation

Walker, Iain

2001-01-01T23:59:59.000Z

499

Remote arctic drilling operations in Russia, case history of Ardalin field operations, Timan Pechora Basin  

SciTech Connect

In developing the Ardalin field, the Polar Lights Company merged Russian and western expertise to conduct drilling operations in a hostile and ecologically sensitive arctic tundra environment. The field is located above the Arctic Circle in northern Russia. The nearest Russian road system is over 60km away and the nearest railhead is 240 km from the field. Three Russian rigs were constructed with selected western upgrades, twelve development wells were drilled, and three existing Russian wells were worked over within a 24 month period. Operations were supported with a snow road in the winter season and Russian helicopter in the summer season. All materials for one year`s worth of drilling had to be transported to the field prior to break-up (end of trucking activities on the snow roads). Services and equipment were sourced from both inside and outside of the Commonwealth of Independent States (CIS). Temperatures in winter reached -45{degrees}C. The field is located in one of the most ecologically sensitive areas in the world, and numerous precautions were taken for the protection of the environment. Russian operating philosophies were successfully merged with western practices. This paper will focus on the operational criteria initiated and infrastructure system that evolved to support this project.

Reyna, E.M.; Nicholson, S.; Brady, S.

1996-12-31T23:59:59.000Z

500

Emergency Operations Training Academy | National Nuclear Security...  

NLE Websites -- All DOE Office Websites (Extended Search)

Emergency Operations Training Academy Emergency Operations Training Academy Emergency Operations Training Academy The Office of Emergency Operations, NA-40-The Emergency Operations...