Powered by Deep Web Technologies
Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Adaptive GPC Structures for Temperature and Relative Humidity Control of a Nonlinear  

E-Print Network [OSTI]

12 Adaptive GPC Structures for Temperature and Relative Humidity Control of a Nonlinear Passive Air and quality when outside air conditions are not favourable. Climate control accuracy may help optimize of climate-controlled greenhouses and growth chambers makes it possible to maintain high crop productivity

Boyer, Edmond

2

SRNL PHASE II SHELF LIFE STUDIES - SERIES 1 ROOM TEMPERATURE AND HIGH RELATIVE HUMIDITY  

SciTech Connect (OSTI)

The Savannah River National Laboratory (SRNL) Phase II, Series 1 shelf-life corrosion testing for the Department of Energy Standard 3013 container is presented and discussed in terms of the localized corrosion behavior of Type 304 stainless steel in contact with moist plutonium oxide and chloride salt mixtures and the potential impact to the 3013 inner container. This testing was designed to address the influence of temperature, salt composition, initial salt moisture, residual stress and type of oxide/salt contact on the relative humidity inside a 3013 container and the initiation and propagation of localized corrosion, especially stress corrosion cracking. The integrated plan is being conducted by Los Alamos National Laboratory and SRNL. SRNL is responsible for conducting a corrosion study in small scale vessels containing plutonium oxide and chloride salts under conditions of humidity, temperature and oxide/salt compositions both within the limits of 3013 storage conditions as well as beyond the 3013 storage requirements to identify margins for minimizing the initiation of stress corrosion cracking. These worst case conditions provide data that bound the material packaged in 3013 containers. Phase I of this testing was completed in 2010. The Phase II, Series 1 testing was performed to verify previous results from Phase I testing and extend our understanding about the initiation of stress corrosion cracking and pitting that occur in 304L under conditions of room temperature, high humidity, and a specific plutonium oxide/salt chemistry. These results will aid in bounding the safe storage conditions of plutonium oxides in 3013 containers. A substantial change in the testing was the addition of the capability to monitor relative humidity during test exposure. The results show that under conditions of high initial moisture ({approx}0.5 wt%) and room temperature stress corrosion cracking occurred in 304L teardrop coupons in contact with the oxide/salt mixture at times as short as 85 days. In all cases, the cracking appeared to be associated with pitting or localized general corrosion. Crack initiation at other sites, such as surface imperfections or inclusions, cannot be excluded. Cracks appear in most cases to initiate through an intergranular mode and transition to a transgranular mode.

Mickalonis, J.; Duffey, J.

2012-09-12T23:59:59.000Z

3

Lead Research and Development Activity for DOE's High Temperature, Low Relative Humidity Membrane Program (Topic 2)  

SciTech Connect (OSTI)

The Department of Energy’s High Temperature, Low Relative Humidity Membrane Program was begun in 2006 with the Florida Solar Energy Center (FSEC) as the lead organization. During the first three years of the program, FSEC was tasked with developing non-Nafion® proton exchange membranes with improved conductivity for fuel cells. Additionally, FSEC was responsible for developing protocols for the measurement of in-plane conductivity, providing conductivity measurements for the other funded teams, developing a method for through-plane conductivity and organizing and holding semiannual meetings of the High Temperature Membrane Working Group (HTMWG). The FSEC membrane research focused on the development of supported poly[perfluorosulfonic acid] (PFSA) – Teflon membranes and a hydrocarbon membrane, sulfonated poly(ether ether ketone). The fourth generation of the PFSA membrane (designated FSEC-4) came close to, but did not meet, the Go/No-Go milestone of 0.1 S/cm at 50% relative humidity at 120 °C. In-plane conductivity of membranes provided by the funded teams was measured and reported to the teams and DOE. Late in the third year of the program, DOE used this data and other factors to decide upon the teams to continue in the program. The teams that continued provided promising membranes to FSEC for development of membrane electrode assemblies (MEAs) that could be tested in an operating fuel cell. FSEC worked closely with each team to provide customized support. A logic flow chart was developed and discussed before MEA fabrication or any testing began. Of the five teams supported, by the end of the project, membranes from two of the teams were easily manufactured into MEAs and successfully characterized for performance. One of these teams exceeded performance targets, while the other requires further optimization. An additional team developed a membrane that shows great promise for significantly reducing membrane costs and increasing membrane lifetime.

James Fenton, PhD; Darlene Slattery, PhD; Nahid Mohajeri, PhD

2012-09-05T23:59:59.000Z

4

Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect (OSTI)

An update is given on the work of the PV Quality Assurance Task Force; Group 3: studying the effects of humidity, temperature, and voltage bias.

Wohlgemuth, J.

2012-03-01T23:59:59.000Z

5

Effect of Changes in Relative Humidity and Temperature on Ultrathin Chitosan Films  

E-Print Network [OSTI]

of infrared absorption measurements of chitosan films collected before and after heating indicate an increase neutralizing the films, they readily absorbed water in the presence of high humidity. Heating of the films in the degree of acetylation with heating. Collectively, these observations are consistent with the release

Dutcher, John

6

ARM - Relative Humidity Calculations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUC :ProductsSCM Forcing Data DerivedInstruments Related LinksCalculatorsRelative

7

Theoretical full power correction factors as related to changes in ambient temperature, pressure and absolute humidity for aircraft turbine engines  

E-Print Network [OSTI]

IN AMBIENT TEMPERATURE, PRESSURF. AND ABSOLUTE HUMIDITY FOR AIRCRAFT TURBINE ENGINES (August 1969) Michael Antoun Raphael B. S. (Mechanical Engineering) Texas A&M University Directed by: Professor Stanley H, Lowy ABSTRACT Power losses in aircraft gas... rated at standard atmospheric conditions (i. e, ambient temperature 69 F 3'Fend atmospheric pressure 29. 92 in. Hg. dry) . Obviously this same turbine will not be exposed to such standard conditions; therefore we have a change in power directly...

Raphael, Michel Antoun

1969-01-01T23:59:59.000Z

8

Group 3: Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect (OSTI)

Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-05-01T23:59:59.000Z

9

Group 3: Humidity, Temperature, and Voltage  

Broader source: Energy.gov [DOE]

This PowerPoint presentation, focused on humidity, temperature and voltage testing, was originally presented by John Wohlgemuth at the NREL 2013 PV Module Reliability Workshop on Feb. 26-27, 2013 in Denver, CO. It summarizes the activities of a working group chartered to develop accelerated stress tests that can be used as comparative predictors of module life versus stresses associated with humidity, temperature and voltage.

10

Group 3: Humidity, Temperature and Voltage (Presentation)  

SciTech Connect (OSTI)

This is a summary of the work of Group 3 of the International PV QA Task Force. Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-09-01T23:59:59.000Z

11

Influence of Sea Surface Temperature on Humidity and Temperature in the Outflow of Tropical Deep Convection  

E-Print Network [OSTI]

-Service Aircraft (MOZAIC) project are analyzed in the vicinity of deep convective outflow to study the variationsInfluence of Sea Surface Temperature on Humidity and Temperature in the Outflow of Tropical Deep upper-tropospheric temperature and humidity by the Mea- surement of Ozone and Water Vapor by Airbus In

Johnson, Richard H.

12

Integrated Temperature and Humidity Control: A Unique Approach  

E-Print Network [OSTI]

as in Singapore. The results presented herein are from one of these sites, consisting of two adjacent unoccupied guest rooms in a hotel, each equipped with chilled- water fan coil units. The two, virtually identical adja- cent rooms were selected primarily... for comparing the operation and performance of the ITHC with that of a dry-bulb temperature controller (DBTC) under the exact same conditions (solar, outdoor temperature and humidity, internal loads, etc.). To obtain com- parative results, the fan coil unit...

Shah, D. J.

2000-01-01T23:59:59.000Z

13

Building America Indoor Temperature and Humidity Measurement Protocol  

SciTech Connect (OSTI)

When modeling homes using simulation tools, the heating and cooling set points can have a significant impact on home energy use. Every 4 years the Energy Information Administration (EIA) Residential Energy Consumption Survey (RECS) asks homeowners about their heating and cooling set points. Unfortunately, no temperature data is measured, and most of the time, the homeowner may be guessing at this number. Even one degree Fahrenheit difference in heating set point can make a 5% difference in heating energy use! So, the survey-based RECS data cannot be used as the definitive reference for the set point for the 'average occupant' in simulations. The purpose of this document is to develop a protocol for collecting consistent data for heating/cooling set points and relative humidity so that an average set point can be determined for asset energy models in residential buildings. This document covers the decision making process for researchers to determine how many sensors should be placed in each home, where to put those sensors, and what kind of asset data should be taken while they are in the home. The authors attempted to design the protocols to maximize the value of this study and minimize the resources required to achieve that value.

Engebrecht-Metzger, C.; Norton, P.

2014-02-01T23:59:59.000Z

14

Problem 7-3: The air enters with a dry-bulb temperature of 50 o F and, at 50% relative humidity, with a wet-  

E-Print Network [OSTI]

cooling water leaves the condenser at To = 8 o F below the temperature of the condensing steam water, leaving the cooling tower and entering the condenser at TCWin = 70 o F, this amount of heat requires a temperature rise in the condenser and corresponding temperature drop in the cooling tower

15

Warm Humid Climate: Methodology to Study Air Temperature Distribution: Mobile Phones Base Stations as Viable Alternative for Fixed Points  

E-Print Network [OSTI]

October to March (considered the summer period). The winter period is rainy, with mild temperatures, high relative humidity and the highest wind speed with predominance in the southeast quadrant. In the first hours of the day, mainly, the wind direction... varies south – southwest. The summer period, from October to March is characterized by higher temperatures, lower relative humidity and relatively low wind speeds with southeast predominance, presenting small variations in the direction east...

Araujo, V.; Costa, A.; Labaki, L.

2006-01-01T23:59:59.000Z

16

High Temperature, Low Relative Humidity, Polymer-type Membranes Based on Disulfonated Poly(arylene ether) Block and Random Copolymers Optionally Incorporating Protonic Conducting Layered Water insoluble Zirconium Fillers  

SciTech Connect (OSTI)

Our research group has been engaged in the past few years in the synthesis of biphenol based partially disulfonated poly(arylene ether sulfone) random copolymers as potential PEMs. This series of polymers are named as BPSH-xx, where BP stands for biphenol, S stands for sulfonated, H stands for acidified and xx represents the degree of disulfonation. All of these sulfonated copolymers phase separate to form nano scale hydrophilic and hydrophobic morphological domains. The hydrophilic phase containing the sulfonic acid moieties causes the copolymer to absorb water. Water confined in hydrophilic pores in concert with the sulfonic acid groups serve the critical function of proton (ion) conduction and water transport in these systems. Both Nafion and BPSH show high proton conductivity at fully hydrated conditions. However proton transport is especially limited at low hydration level for the BPSH random copolymer. It has been observed that the diffusion coefficients of both water and protons change with the water content of the pore. This change in proton and water transport mechanisms with hydration level has been attributed to the solvation of the acid groups and the amount of bound and bulk-like water within a pore. At low hydration levels most of the water is tightly associated with sulfonic groups and has a low diffusion coefficient. This tends to encourage isolated domain morphology. Thus, although there may be significant concentrations of protons, the transport is limited by the discontinuous morphological structure. Hence the challenge lies in how to modify the chemistry of the polymers to obtain significant protonic conductivity at low hydration levels. This may be possible if one can alter the chemical structure to synthesize nanophase separated ion containing block copolymers. Unlike the BPSH copolymers, where the sulfonic acid groups are randomly distributed along the chain, the multiblock copolymers will feature an ordered sequence of hydrophilic and hydrophobic segments. If, like in Nafion, connectivity is established between the hydrophilic domains in these multiblock copolymers, they will not need as much water, and hence will show much better protonic conductivity than the random copolymers (with similar degree of sulfonation, or IEC) at partially hydrated conditions. The goal of this research is to develop a material suitable for use as a polymer electrolyte membrane which by the year 2010 will meet all the performance requirements associated with fuel cell operation at high temperatures and low relative humidity, and will out-perform the present standard Nafion{reg_sign}. In particular, it is our objective to extend our previous research based on the use of thermally, oxidatively, and hydrolytically, ductile, high Tg ion containing polymers based on poly(arylene ethers) to the production of polymer electrolyte membranes which will meet all the performance requirements in addition to having an areal resistance of < 0.05 ohm-cm{sup 2} at a temperature of up to 120 C, relative humidity of 25 to 50%, and up to 2.5 atm total pressure. In many instances, our materials already out performs Nafion{reg_sign}, and it is expected that with some modification by either combining with conductive inorganic fillers and/or synthesizing as a block copolymer it will meet the performance criteria at high temperatures and low relative humidity. A key component in improving the performance of the membranes (and in particular proton conductivity) and meeting the cost requirements of $40/m{sup 2} is our development of a film casting process, which shows promise for generation of void free thin films of uniform thickness with controlled polymer alignment and configuration.

McGrath, James E.; Baird, Donald G.

2010-06-03T23:59:59.000Z

17

RELATIVE HUMIDITY TESTS IN SUPPORT OF THE 3013 STORAGE AND SURVEILLANCE PROGRAM  

SciTech Connect (OSTI)

Techniques to control the initial relative humidity over oxide/salt mixtures have been developed using cerium oxide as a surrogate for plutonium oxide. Such control is required to validate certain assumptions in the Department of Energy Standard DOE-STD-3013, and to provide essential information to support field surveillance at the storage sites for excess plutonium oxides. Concern over the validity of the assumption that corrosion induced degradation in 3013 containers could be controlled by assuring that the moisture content of any stored oxide/salt mixture was below 0.5 w t% arose when stress corrosion cracks were found in test samples exposed at room temperature to plutonium oxide/salt mixtures having a moisture content only marginally above 0.5 wt %. Additionally, analysis of the stress corrosion cracking observations suggests that the initial relative humidity over the oxide/salt mixture may play a major role in the cracking process. The investigations summarized in this report provide the procedures necessary to control the initial relative humidity to selected values within the range of 16 to 50% by controlling the loading relative humidity (18 to 60%) and the oxide/salt mixture water content (0.05 to 0.45 wt %). The studies also demonstrated that the initial relative humidity may be estimated by calculations using software EQ3/6. Cerium oxide/salt mixtures were used in this study because qualification tests with non-radioactive materials will reduce costs while increasing the breadth of the test programs required to support field surveillances of stored 3013 containers.

Mickalonis, J.; Duffey, J.

2011-08-01T23:59:59.000Z

18

High Temperature/Low Humidity Polymer Electrolytes Derived from Ionic Liquids  

Broader source: Energy.gov [DOE]

Presentation on High Temperature/Low Humidity Polymer Electrolytes Derived from Ionic Liquids to the High Temperature Membrane Working Group Meeting held in Arlington, Virginia, May 26,2005.

19

Understanding the Temperature and Humidity Environment Inside a PV Module (Presentation), NREL (National Renewable Energy Laboratory)  

Broader source: Energy.gov [DOE]

This PowerPoint presentation was originally given by Michael Kempe of NREL in February 2013 detailing a project funded by the SunShot Initiative. Understanding the Temperature and Humidity Environment Inside a PV Module aims to show that by choosing humidity conditions that more closely match the use environment, one can minimize the uncertainty associated with moisture induced degradation modes.

20

An Experimental Evaluation of HVAC-Grade Carbon-Dioxide Sensors: Part 3, Humidity, Temperature, and Pressure Sensitivity Test Results  

SciTech Connect (OSTI)

This is the third paper in a four-part series reporting on the test and evaluation of typical carbon-dioxide sensors used in building HVAC applications. Fifteen models of NDIR HVAC-grade CO2 sensors were tested and evaluated to determine the humidity, temperature, and pressure sensitivity of the sensors. This paper reports the performance of the sensors at various relative humidity, temperature, and pressure levels common to building HVAC applications and provides a comparison with manufacturer specifications. Among the 15 models tested, eight models have a single-lamp, single-wavelength configuration, four models have a dual-lamp, single-wavelength configuration, and three models have a single-lamp, dual-wavelength configuration. The sensors were tested in a chamber specifically fabricated for this research. A description of the apparatus and the method of test are described in Part 1 (Shrestha and Maxwell 2009). The test result showed a wide variation in humidity, temperature, and pressure sensitivity of CO2 sensors among manufacturers. In some cases, significant variations in sensor performance exist between sensors of the same model. Even the natural variation in relative humidity could significantly vary readings of some CO2 sensor readings. The effects of temperature and pressure variation on NDIR CO2 sensors are unavoidable without an algorithm to compensate for the changes. For the range of temperature and pressure variation in an air-conditioned space, the effect of pressure variation is more significant compared to the effect of temperature variation.

Shrestha, Som S [ORNL; Maxwell, Dr. Gregory [Iowa State University

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Simulation and Optimization of the Temperature and Humidity Independent Control Showcase  

E-Print Network [OSTI]

A new kind of showcase with temperature and humidity independent control is introduced in this paper to reduce the energy consumption of the showcase's air-conditioning system. Computational Fluid Dynamics was employed to investigate this new...

Hou, H.; Yu, L.; Wan, X.; Chen, H.

2006-01-01T23:59:59.000Z

22

Effects of Sodium Chloride Particles, Ozone, UV, and Relative Humidity on Atmospheric Corrosion of Silver  

E-Print Network [OSTI]

Effects of Sodium Chloride Particles, Ozone, UV, and Relative Humidity on Atmospheric Corrosion The corrosion of Ag contaminated with NaCl particles in gaseous environments containing humidity and ozone analyzed using a coulometric reduction technique. The atmospheric corrosion of Ag was greatly accelerated

23

Temperature and humidity control during cooling and dehumidifying by compressor and evaporator fan speed variation  

SciTech Connect (OSTI)

The accurate control of temperature and relative humidity during cooling and dehumidifying air-conditioning processes may be achieved by compressor and evaporator fan speed variation. Proportional-integral-differential (PID) control methods are shown to be suitable for attaining compressor and evaporator fan speeds such that the sensible and latent components of the refrigeration system capacity equal the sensible and latent components of the system load. The feasibility of the control method has been verified experimentally. A numerical model of an environmental control system, including refrigeration, space, and PID control subsystems, has been developed. The model is suitable for determining system response to variations of PID coefficient values and to variations of system loads.

Krakow, K.I.; Lin, S.; Zeng, Z.S. [Concordia Univ., Montreal, Quebec (Canada). Dept. of Mechanical Engineering

1995-08-01T23:59:59.000Z

24

Comparison of temperature and humidity profiles with elastic-backscatter lidar data  

SciTech Connect (OSTI)

This contribution analyzes elastic-backscatter lidar data and temperature and humidity profiles from radiosondes acquired in Barcelona in July 1992. Elastic-backscatter lidar data reveal the distribution of aerosols within the volume of atmosphere scanned. By comparing this information with temperature and humidity profiles of the atmosphere at a similar time, we are able to asses de relationship among aerosol distribution and atmospheric stability or water content, respectively. Comparisons have shown how lidar`s revealed layers of aerosols correspond to atmospheric layers with different stability condition and water content.

Soriano, C. [Universidad Politecnica de Cataluna, Barcelona (Spain)]|[Los Alamos National Lab., NM (United States); Buttler, W.T. [Los Alamos National Lab., NM (United States); Baldasano, J.M. [Universidad Politecnica de Cataluna, Barcelona (Spain)

1995-04-01T23:59:59.000Z

25

Maintaining Space Temperature and Humidity in the Digital Switch Environment  

E-Print Network [OSTI]

the humidifier if Case A-l is used, Btu/lb Dhjj = enthalpy difference across the humidifier if Case A-2 is used, Btu/lb Dhcnjner = enthalpy difference across the sensible cooling process, case A-2, Btu/lb Case B: The outside air dry bulb temperature is higher.... Isothermal humidification (steam generator or infrared heater). b. Adiabatic humidification (evaporative cooler or ultrasonic humidification). METHODOLOGY 1. Obtain the bin data for the location (see Table 1 below for sample bin data). Table 1. Temperature...

Saman, N. F.; Johnson, H.

26

A theoretical model for adsorption capacities of charcoal beds: I, Relative humidity effects  

SciTech Connect (OSTI)

Water vapor is the major interferent in the adsorption of other vapors from air when that air is passed through an activated charcoal bed. A limited amount of data (published and unpublished) is available on the magnitudes of capacity (or service life) reduction as a function of relative humidity (water vapor concentration) and preadsorbed water. A simple equilibrium model has been developed which quantitatively explains observed humidity effects and allows extrapolation of data to untested conditions. 9 refs., 4 figs., 2 tabs.

Wood, G.O.

1987-01-01T23:59:59.000Z

27

Effects of Temperature and Humidity on the Characterization of C-4 Explosive Threats  

SciTech Connect (OSTI)

The amount of time that an explosive is present on the surface of a material is dependent upon the original amount of explosive on the surface, adhesive forces, temperature and humidity, as well as other environmental factors. This laboratory study focused on evaluating RDX crystal morphology changes resulting from variations in temperature and humidity conditions of the sample. The temperature and humidity conditions were controlled using a Tenney THRJ environmental chamber and a Tenney T11RC-1.5 environmental chamber. These chambers allow the temperature and humidity to be held within ±3°C and ±5% RH. The temperature and humidity conditions used for this test series were: 40°F/40%RH, ~70°F/20%RH (samples left on benchtop), 70°F/70%RH, 70°F/95%RH, 95°F/40%RH, 95°F/70%RH, and 95°F/95%RH. These temperature and humidity set points were chosen to represent a wide range of conditions that may be found in real world scenarios. C-4 (RDX crystals and binder material) was deposited on the surface of one of six substrates by placing a fingerprint from the explosive block onto the matrix surface. The substrates were chosen to provide a range of items that are commonly used. Six substrate types were used during these tests: 50% cotton/50% polyester as found in T-shirts, 100% cotton with a smooth surface such as that found in a cotton dress shirt, 100% cotton on a rough surface such as that found on canvas or denim, suede leather such as might be found on jackets, purses, or shoes, painted metal obtained from a junked car hood, and a computer diskette. The samples were not pre-cleaned prior to testing and contained sizing agents, and in the case of the metal: oil, dirt, scratches, and rust spots. The substrates were photographed at various stages of testing, using a Zeiss Discover V12 stereoscope with Axiocam ICc1 3 megapixel digital camera, to determine any changes in the crystalline morphology. Some of the samples were examined using scanning electron microscopy (SEM) and atomic force microscopy (AFM) in an attempt to determine how the explosive was bound to the substrate.

C. J. Miller

2012-06-01T23:59:59.000Z

28

Analytical determination of PID coefficients for temperature and humidity control during cooling and dehumidifying by compressor and evaporator fan speed variation  

SciTech Connect (OSTI)

A linearized analysis of temperature and relative humidity control using proportional-integral-differential (PID) controls to vary compressor motor speed and evaporator fan speed enables analytical determination of suitable PID coefficients. The PID coefficients are related to refrigeration system performance parameters and the volume of the conditioned space. Analytical determination of coefficients may eliminate or supplement trial-and-error methods. System response characteristics--damping ratios and periods--are related to PID coefficients, sampling intervals, performance parameters of a refrigeration system, and the volume of a conditioned space. Two control strategies are possible in order to control space temperature and relative humidity simultaneously. One strategy controls temperature by varying compressor speed and controls relative humidity by varying evaporator fan speed. The other strategy controls temperature by varying evaporator fan speed and controls relative humidity by varying compressor fan speed The first strategy was successfully implemented experimentally as well as by simulation. The second strategy was not successfully implemented due to an adverse interaction between the two control systems.

Krakow, K.I.; Lin, S.; Zeng, Z.S. [Concordia Univ., Montreal, Quebec (Canada). Dept. of Mechanical Engineering

1995-08-01T23:59:59.000Z

29

IEC Quality Assurance Task Group 5: UV, Temperature, and Humidity (Presentation)  

SciTech Connect (OSTI)

Taskgroup 5 (TG5) is concerned with a comparative aging standard incorporating factors including ultraviolet radiation, temperature, and humidity. Separate experiments are being conducted in support of a test standard via the regional sub-groups in Asia, Europe, and the United States. The authors will describe the objectives and timeline for TG5 as well as providing an update on the experiments in progress.

Miller, D.; Bath, J.; Kohl, M.; Shioda, T.

2014-03-01T23:59:59.000Z

30

Modeling Effects of Relative Humidity, Moisture, and Extreme Environmental Conditions on Power Electronic Performance  

E-Print Network [OSTI]

this knowledge during the design phase can improve the reliability of the equipment, thereby reducing failures and dropping maintenance costs. Some of the environmental conditions affecting electronic equipment and systems]. For instance in a data center or computer room, relative humidity has to be maintained between 45% and 55

Lehman, Brad

31

Development of empirical temperature and humidity-based degraded-condition indicators for low-tonnage air conditioners  

E-Print Network [OSTI]

A split-system direct-expansion air conditioner was used to empirically determine temperature and return-air humidity indicators that could detect performance degradation resulting from degraded conditions. The air conditioner test bench...

Watt, James Bonner

1997-01-01T23:59:59.000Z

32

The Temperature and Relative Humidity Control in Cushing Library  

E-Print Network [OSTI]

humidifier, and heat recovery. The chilled water to the standard cooling coil is served by the chilled water loop on the campus. There is a glycol chiller for the glycol cooling coil for added dehumidification ability. Because of programming problems...

Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D.; Bruner, H., Jr.

2002-01-01T23:59:59.000Z

33

Humidity-resistant ambient-temperature solid-electrolyte amperometric sensing apparatus  

DOE Patents [OSTI]

Apparatus and methods for detecting selected chemical compounds in air or other gas streams at room or ambient temperature includes a liquid-free humidity-resistant amperometric sensor comprising a sensing electrode and a counter and reference electrode separated by a solid electrolyte. The sensing electrode preferably contains a noble metal, such as Pt black. The electrolyte is water-free, non-hygroscopic, and substantially water-insoluble, and has a room temperature ionic conductivity [>=]10[sup [minus]4] (ohm-cm)[sup [minus]1], and preferably [>=]0.01 (ohm-cm)[sup [minus]1]. The conductivity may be due predominantly to Ag[sup +] ions, as in Ag[sub 2]WO[sub 4], or to F[sup [minus

Zaromb, S.

1994-06-21T23:59:59.000Z

34

Natural and accelerated CO{sub 2} binding kinetics in cement paste at different relative humidities  

SciTech Connect (OSTI)

Natural carbonation and accelerated carbonation are compared in terms of CO{sub 2} combination. Thermogravimetrical analysis, neutron diffraction and weight measurements were used to quantify the amounts of CO{sub 2} in samples exposed to different CO{sub 2} and relative humidity (RH) conditions. An exponential equation is proposed to describe temporal evolution: combination rates and maximum values are obtained both for natural and accelerated processes. The influence of RH in these parameters is analyzed. At 100% CO{sub 2} an increase of RH from 53 to 75% diminishes the combination rate considerably, but increases slightly the maximum CO{sub 2} binding. At 0.5% CO{sub 2} both the rate and the maximum are higher for intermediate RH, with a linear relation between both variables. Equivalences between the different processes have been calculated: the amount of CO{sub 2} combined in 1 h at 100% CO{sub 2} and 65% RH carbonation is equivalent to approximately 36 days of natural exposure outside and 54 days inside.

Galan, Isabel, E-mail: isabelgalan@abdn.ac.uk [University of Aberdeen, Department of Chemistry, Meston Walk, AB24 3UE (United Kingdom)] [University of Aberdeen, Department of Chemistry, Meston Walk, AB24 3UE (United Kingdom); Andrade, Carmen; Castellote, Marta [Eduardo Torroja Institute CSIC, Serrano Galvache 4, 28033 Madrid (Spain)] [Eduardo Torroja Institute CSIC, Serrano Galvache 4, 28033 Madrid (Spain)

2013-07-15T23:59:59.000Z

35

Understanding the Temperature and Humidity Environment Inside a PV Module (Presentation)  

SciTech Connect (OSTI)

This presentation addresses moisture-driven degradation processes in PV modules and the conditions to use for accelerated stress testing. Here we show that by choosing humidity conditions that more closely match the use environment, one can minimize the uncertainty associated with moisture induced degradation modes.

Kempe, M.

2013-06-01T23:59:59.000Z

36

Diagnosis of Zonal Mean Relative Humidity Changes in a Warmer Climate JONATHON S. WRIGHT* AND ADAM SOBEL  

E-Print Network [OSTI]

gases and one with doubled CO2. A set of last saturation tracers is applied within the tracer transport relative humidity response to a doubling of CO2 in a climate model is examined using a global climate model JOSEPH GALEWSKY Department of Earth and Planetary Sciences, University of New Mexico, Albuquerque, New

Sobel, Adam

37

A logical extension of the ASTM Standard E96 to determine the dependence of water vapor transmission on relative humidity  

SciTech Connect (OSTI)

It is well known that the water vapor transmission properties of hygroscopic building materials depend on the local relative humidities(rh). Traditionally, the ASTM Standard E96 specifies only two conditions of rh. The dry cup method in the standard corresponds to a mean rh of 25% and the wet cup to 75%. This information is not enough to describe the behavior of the material through the entire range of rh. European Standards have already proposed an extension of the existing standard to address this issue. ASTM standard should follow this change. A logical extension of the E96 standard to include the effect of rh on water vapor transmission properties has been proposed and is being discussed by one of the C16 Committee Task Groups. This paper presents the application of the proposed extension to several common building materials. The details include the operating principles of a constant temperature-rh chamber and the effects on the test results, of the vapor resistance offered by still air inside the cup, the surface resistances and buoyancy. The experimental data were used to critically assess the above effects. The data as well as the analyses of the data are expected to provide guidance to refine the existing ASTM Standard.

Lackey, J.C.; Marchand, R.G.; Kumaran, M.K. [National Research Council of Canada, Ottawa, Ontario (Canada). Inst. for Research in Construction

1997-11-01T23:59:59.000Z

38

IEEE GEOSCIENCE AND REMOTE SENSING LETTERS 1 Assessment of Temperature and Humidity Changes  

E-Print Network [OSTI]

IEEEProof IEEEProof IEEE GEOSCIENCE AND REMOTE SENSING LETTERS 1 Assessment of Temperature multiple satellite7 remote sensing data sets and meteorological information, we assess8 the distribution observed at some15 locations. Between the surface and 2-km level, temperature data16 show a cooling of 10

Christopher, Sundar A.

39

The herbicidal effectiveness of 2,4-dichlorophenoxyacetic acid and 2,3,6,-trichlorobenzoic acid on beans as influenced by relative humidity and droplet size  

E-Print Network [OSTI]

, the author, would like to acknowledge the suggestions of Mr. Wayne G. McCully and Dr. Robert A. Darrow which led to the origination of this study. The advise and help of Mr. McCully during the preparation and experimentation were invaluable... established that relative humidity influences plant growth (Nightingale and Mitchell, 1934) . Tomatoes grown at 35% relative humidity had less chlorophyll, thicker cell walls, higher total carbohydrates and a slower growth rate than plants grown at 95...

Morgan, Page Wesley

1958-01-01T23:59:59.000Z

40

IEC Quality Assurance Task Group 5: UV, Temperature, and Humidity (Presentation)  

SciTech Connect (OSTI)

Taskgroup 5 (TG5) is concerned with a comparative aging standard incorporating factors including ultraviolet radiation and temperature. Separate experiments are being conducted in support of a test standard via the regional sub-groups in Asia, Europe, and the United States. The authors will describe the objectives and timeline for TG5 as well as providing an update on the experiments in progress.

Miller, D.; Bath, J.; K& ouml; hl, M.; Shioda, T.

2014-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

A FULLY COUPLED THERMO-HYDRO MECHANICAL ANALYSIS OF THE IMPACT OF TEMPERATURE AND HUMIDITY VARIATION ON THE STATE OF HISTORICAL STONE  

E-Print Network [OSTI]

A FULLY COUPLED THERMO-HYDRO MECHANICAL ANALYSIS OF THE IMPACT OF TEMPERATURE AND HUMIDITY Keywords: Thermo-hydro-mechanical coupling, modelling, inverse problem, tuffeau, monument, in situ measures initiation and growth due to the variation of climate conditions; thermo-hydro-mechanical incompatibility

Paris-Sud XI, Université de

42

The determination of interference levels of temperature and humidity on continuous monitoring of diisocyanate  

E-Print Network [OSTI]

to standard conditions of 25 C and 760 mm Hg: Vs VX P X 760 T + 273 where: Vs V P T volume of air(L) 9 25 C and 760 mm Hg volume of air(L) as measured barometric pressure in mm Hg temperature of air in degree centrigrade Appendix p Equipment... of Analysis 28 Experimental Procedure . . . . . . . . . 29 RESULTS AND DISCUSSION ~ ~ ~ ~ 5 1 x1 Qmyz, IS rqw SPIC, 0 0 Qs PL 0-- T QX S CQQ l' t D g %70% S, Qg DD jJ D ~vSwg D( , ZS 2 4a 46 ~PP:"NDIX e ":xperimen+al Condi+ions fo" &umidity...

Ryan, Donald Arden

2012-06-07T23:59:59.000Z

43

Humidity Control in Residences  

E-Print Network [OSTI]

. By introducing a separate vapor compression unit to pre-condition outside air, indoor relative humidity can be controlled. This new air conditioning system combines a ventilation unit with a conventional recirculation air conditioning unit. Although successful...

Trowbridge, J.; Peterson, J.

1994-01-01T23:59:59.000Z

44

20th Century Reanalysis Project Ensemble Gateway: 56 Estimates of World Temperature, Pressure, Humidity, and Wind, 1871-2010  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

This site provides data from the 20th Century Reanalysis Project, offering temperature, pressure, humidity, and wind predictions in 200 km sections all around the earth from 1871 to 2010, every 6 hours, based on historical data. The ensemble mean and standard deviation for each value were calculated over a set of 56 simulations. Data for each of the 56 ensemble members are included here. The dataset consists of files in netCDF 4 format that are available for download from the National Energy Research. The goal of the 20th Century Reanalysis Project is to use a Kalman filter-based technique to produce a global trophospheric circulation dataset at four-times-daily resolution back to 1871. The only dataset available for the early 20th century consists of error-ridden hand-drawn analyses of the mean sea level pressure field over the Northern Hemisphere. Modern data assimilation systems have the potential to improve upon these maps, but prior to 1948, few digitized upper-air sounding observations are available for such a reanalysis. The global tropospheric circulation dataset will provide an important validation check on the climate models used to make 21st century climate projections....[copied from http://portal.nersc.gov/project/20C_Reanalysis/

45

The use of data from the NIMBUS II satellite to determine the mean relative humidity in the layer below 500 mb  

E-Print Network [OSTI]

THE USE OF DATA FROM THE NIMBUS II SATELLITE TO DETERMINE THE MEAN RELATIVE HUMIDITY IX THE LAYER BELOW 500 MB A Thesis JOHN FRAJVCIS MORRISSETTE Major, USAF Submitted to the Graduate College of the Texas ARM University in partial fulfillment... as to style and content by: (Ch rrman of Committee) (Head of Departme & (Member) (Member) (Member) May 1967 ABSTRACT The Use of Data From the NIMBUS II Satellite to Determine the Mean Relative Humidity in the Layer Below 500 mb. (May 1967) John Francis...

Morrissette, John Francis

1967-01-01T23:59:59.000Z

46

Evaluation of ANSI N42-17A by investigating the effects of temperature and humidity on the response of radiological instruments  

SciTech Connect (OSTI)

The American National Standards Institute (ANSI) N42.17A-1989 standard`s performance criteria and test methods has been evaluated by investigating the effects of temperature and humidity on the response of 105 portable direct-reading radiological instruments (45 beta-gamma survey meters, 32 neutron rem meters, 1O alpha contamination and 18 tritium-in-air monitors). The US Department of Energy (DOE) mandates the use of ANSI standards for the calibration and performance testing of radiological instruments, and requires that instruments be appropriate for existing environmental conditions. Random tests conducted in an environmental chamber determined the effects of temperatures ranging from {minus}10{degree}C to 50{degree}C and humidity at levels of 40% RH and 95% RH on the response of a cross section of instruments used in routine health physics operations at Los Alamos. The following instruments were tested: Eberline RO-2 and RO-C ionization chambers, Eberline E-530 survey meter with the Model HP-C stainless steel Geiger-Muller (G) wall probe, Eberline PIC-6A and PIC-6B ion chambers, Eberline ESP-1 survey meter with the Model HP-260 pancake G detector, Ludlum 3 survey meter with the Model 44-6 stainless steel G wall probe, Eberline ESP-1, ESP-2 and PAR-4 survey meters with the neutron rem detector, Health Physics Instruments 2080 survey meter with the moderator detector, Ludlum 139 survey meter with the Model 43-32 air-proportional alpha detector, and the Overhoff 394-C, Johnston J-111 and J-110 tritium monitors. Experimental results encompass 1128 temperature tests (1269-hours exposure in the chamber) and 735 humidity tests (1890-hours exposure in the chamber). The study shows the standard`s test requirement for temperature at or near the extreme conditions, and the standard`s test requirement for humidity at 95% RH may be too restrictive for instruments used in the work environment.

Clement, R.S.

1995-06-01T23:59:59.000Z

47

Light Absorption by Secondary Organic Aerosol from ?-Pinene: Effects of Oxidants, Seed Aerosol Acidity, and Relative Humidity  

SciTech Connect (OSTI)

It is well known that light absorption from dust and black carbon aerosols has a warming effect on climate while light scattering from sulfate, nitrate, and sea salt aerosols has a cooling effect. However, there are large uncertainties associated with light absorption and scattering by different types of organic aerosols, especially in the near-UV and UV spectral regions. In this paper, we present the results from a systematic laboratory study focused on measuring light absorption by secondary organic aerosols (SOA) generated from ozonolysis or NO3 oxidation of ?-pinene in the presence of neutral and acidic sulfate seed aerosols. Light absorption was monitored using photoacoustic spectrometers at four different wavelengths: 355, 405, 532 and 870 nm. Light absorption at 355 and 405 nm was observed by SOA generated from oxidation of ?-pinene in the presence of acidic sulfate seed aerosols, under dry conditions. No absorption was observed when the relative humidity was elevated to greater than 27%, or in the presence of neutral sulfate seed aerosols. The light-absorbing compounds are speculated to be aldol condensation oligomers with organosulfate and organic nitrate groups. The results of this study also indicate that organic nitrates from ?-pinene SOA formed in the presence of neutral sulfate seed aerosols do not appear to absorb near-UV and UV radiation.

Song, Chen; Gyawali, Madhu S.; Zaveri, Rahul A.; Shilling, John E.; Arnott, W. Patrick

2013-10-25T23:59:59.000Z

48

Humidity requirements in WSCF Laboratories  

SciTech Connect (OSTI)

The purpose of this paper is to develop and document a position on Relative Humidity (RH) requirements in the WSCF Laboratories. A current survey of equipment vendors for Organic, Inorganic and Radiochemical laboratories indicate that 25% - 80% relative humidity may meet the environmental requirements for safe operation and protection of all the laboratory equipment.

Evans, R.A.

1994-10-01T23:59:59.000Z

49

The effect of temperature and relative humidity levels upon charcoal tube sampling for vinyl choloride  

E-Print Network [OSTI]

their cooperation, this research would not have been possible. I also wish to express my appreciation to the National Institute for Occupational Safety and Health which prov ided an educational grant. DEDICATION To Ann, Your love, words of encouragement... of their employees from angiosarcoma to prolonged vinyl chloride monomer (UCM) exposure. (I) The government immediately stepped in, and by Febr uary 1974, the National Institute for Occupational Safety and Health (NIOSH) had issued a set of recommendations...

McCaskill, Gerald Daniel

1983-01-01T23:59:59.000Z

50

The frequency of tropopause-level thick and thin cirrus clouds as observed by CALIPSO and the relationship to relative humidity and outgoing longwave radiation  

E-Print Network [OSTI]

schematic of the location of the SPCZ and the ITCZ in the Pacific Ocean................................................... 40 3 Three month average of outgoing longwave radiation (OLR) for DJF provided by the NOAA/OAR/ESRL PSD... THE FREQUENCY OF TROPOPAUSE-LEVEL THICK AND THIN CIRRUS CLOUDS AS OBSERVED BY CALIPSO AND THE RELATIONSHIP TO RELATIVE HUMIDITY AND OUTGOING LONGWAVE RADIATION A Thesis by ALLISON L. CARDONA Submitted to the Office of Graduate...

Cardona, Allison Leanne

2008-10-10T23:59:59.000Z

51

Measure Guideline: Supplemental Dehumidification in Warm-Humid Climates  

SciTech Connect (OSTI)

This document covers a description of the need and applied solutions for supplemental dehumidification in warm-humid climates, especially for energy efficient homes where the sensible cooling load has been dramatically reduced. In older homes in warm-humid climates, cooling loads are typically high and cooling equipment runs a lot to cool the air. The cooling process also removes indoor moisture, reducing indoor relative humidity. However, at current residential code levels, and especially for above-code programs, sensible cooling loads have been so dramatically reduced that the cooling system does not run a lot to cool the air, resulting in much less moisture being removed. In these new homes, cooling equipment is off for much longer periods of time especially during spring/fall seasons, summer shoulder months, rainy periods, some summer nights, and some winter days. In warm-humid climates, those long off periods allow indoor humidity to become elevated due to internally generated moisture and ventilation air change. Elevated indoor relative humidity impacts comfort, indoor air quality, and building material durability. Industry is responding with supplemental dehumidification options, but that effort is really in its infancy regarding year-round humidity control in low-energy homes. Available supplemental humidity control options are discussed. Some options are less expensive but may not control indoor humidity as well as more expensive and comprehensive options. The best performing option is one that avoids overcooling and avoids adding unnecessary heat to the space by using waste heat from the cooling system to reheat the cooled and dehumidified air to room-neutral temperature.

Rudd, A.

2014-10-01T23:59:59.000Z

52

High-temperature thermocouples and related methods  

DOE Patents [OSTI]

A high-temperature thermocouple and methods for fabricating a thermocouple capable of long-term operation in high-temperature, hostile environments without significant signal degradation or shortened thermocouple lifetime due to heat induced brittleness.

Rempe, Joy L. (Idaho Falls, ID); Knudson, Darrell L. (Firth, ID); Condie, Keith G. (Idaho Falls, ID); Wilkins, S. Curt (Idaho Falls, ID)

2011-01-18T23:59:59.000Z

53

Mean Radiant Cooling in a Hot-Humid Climate  

E-Print Network [OSTI]

degree F the mean radiant temperam of surrounding interior wall surfaces is lowered, air temperature may be increased 1.4 degrees F and thermal comfort will still be maintained." For example at the same relative humidity an interior room with the MRT...-circulate internal air e 250 fpm- piaster r-8 insulatio- 8' conc. wall ---, fiashinq~' r 18 slab insul \\ .. S::ar rnduced ventilation d I I Tin = 82'F fig. 1. Thermal Grounding ivith u deep foundation beam Hot-humid climates usually have early morning...

Garrison, M.

1996-01-01T23:59:59.000Z

54

Evaluation of Energy Efficiency Measures in Hot and Humid Climates  

E-Print Network [OSTI]

Hot and humid climates present some of the most complex challenges for sustainable building designs. High temperatures coupled with high humidity create extreme comfort problems and exacerbate the potential for condensation, mold and mildew...

Zhao, Y.; Erwine, B.; Leonard, P.; Pease, B.; Dole, A.; Lee, A.

55

Development of a Humid Climate Definition  

E-Print Network [OSTI]

located in humid climates. The draft standard included a definition of humid climate: where, during the warmest six consecutive months of a typical year, the wetbulb temperature is 19°C (67°F) or higher for 3500 hours or more, or 23°C (73°F) or higher...

Hedrick, R. L.; Shirey, D. B.

1998-01-01T23:59:59.000Z

56

Humidity variations in the atmospheric surface layer  

E-Print Network [OSTI]

anemometer system used in this study, computed for five different wind speeds. 15 View from micrometeorologi cal tower towards the direction from which the wind was blowing for most of the runs select- ed. The left hand side is roughly 230' and the right... ASM Department of Meteorology by the Climatro- nics Corporation. The system consists of three sets of fast response wind, temperature, and relative humidity sensors, as well as a data acquisition system and a tape drive to store the data on magnetic...

Humphrey, Scott Richard

2012-06-07T23:59:59.000Z

57

Temperature-Dependent Chemical Properties of  

E-Print Network [OSTI]

Silberstein #12;What is a fuel cell? #12;Polymer Electrolyte Membrane Two phase ionomer (ionic polymer temperatures (thermal history) and relative humidities Temperatures 150o C for 1 hour 100o C, 90o C, 80o C, 70o

Petta, Jason

58

Considerations for Energy Efficient Showers in Hot-Humid Climates  

E-Print Network [OSTI]

CONSIDERATIONS FOR ENERGY EFFICIENT SHOWERS IN HOT-HUMID CLIMATES D. E. Claridge and W.D. Turner Energy Systems Laboratory Department of Mechanical Engineering Texas ALM University ABSTRACT Measurements have been conducted on four low... for typical operation in Texas. This has significant implications for everyone who purchases or uses showerheads; this is particularly true in hot climates where supply water temperatures are relatively high. TESTS CONDUCTED Showerheads Tested Two...

Claridge, D. E.; Turner, W. D.

1989-01-01T23:59:59.000Z

59

Case Study: Sick Building Syndrome in a Humid Climate  

E-Print Network [OSTI]

and evaluation; formaldehyde sampling; particulate sampling; bioaerosol sampling (consisting of nonviable and viable fungi spore sampling); carbon monoxide, carbon dioxide, temperature and relative humidity levels to be monitored over 12-hour periods on two... to the outside" (25). To date, no single satisfactory method is available to measure the amount of cigarette smoke present in a work space. Carbon monoxide and formaldehyde levels were monitored throughout the second and fourth floors to attempt...

Shaughnessy, R. J.; Levetin, E.

1990-01-01T23:59:59.000Z

60

The effect of temperature on relative permeability of unconsolidated sand  

E-Print Network [OSTI]

THE EFFECT OF TEMPERATURE ON RELATIVE PERMEABILITY OF UNCONSOLIDATED SAND A Thesis By SIMON YSRAEL Submitted to the Graduate College of the Texas A%M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE.... Summary of Water Flood at 150 F VII. Summary of Water Flood at 293 F 48 49 50 ABSTRACT The purpose of this work was to investigate the effect of temperature on relative permeability of unconsolidated sand. The present work was performed...

Ysrael, Simon

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Demand Controlled Ventilation for Improved Humidity Control  

E-Print Network [OSTI]

only C02, the systems now being installed also monitor dew point (and relative humidity). The capability of including VOC monitoring has also been demonstrated in a recent installation. Other IAQ parameters such as CO, ozone, formaldehyde and SOX...

Rogers, J. K.

1996-01-01T23:59:59.000Z

62

Novel Approaches to Immobilized Heteropoly Acid Systems for High Temperature, Low Relative Humidity Polymer-Type Membranes - Final Report  

SciTech Connect (OSTI)

Original research was carried out at the CSM and the 3M Company from March 2007 through September 2011. The research was aimed at developing new to the world proton electrolyte materials for use in hydrogen fuel cells, in particular with high proton conductivity under hot and dry conditions (>100mS/cm at 120°C and 50%RH). Broadly stated, the research at 3M and between 3M and CSM that led to new materials took place in two phases: In the first phase, hydrocarbon membranes that could be formed by photopolymerization of monomer mixtures were developed for the purpose of determining the technical feasibility of achieving the program's Go/No-Go decision conductivity target of >100mS/cm at 120°C and 50%RH. In the second phase, attempts were made to extend the achieved conductivity level to fluorinated material systems with the expectation that durability and stability would be improved (over the hydrocarbon material). Highlights included: Multiple lots of an HPA-immobilized photocurable terpolymer derived from di-vinyl-silicotungstic acid (85%), n-butyl acrylate, and hexanediol diacrylate were prepared at 3M and characterized at 3M to exhibit an initial conductivity of 107mS/cm at 120°C and 47%RH (PolyPOM85v) using a Bekktech LLC sample fixture and TestEquity oven. Later independent testing by Bekktech LLC, using a different preheating protocol, on the same material, yielded a conductivity value of approximately 20mS/cm at 120°C and 50%RH. The difference in measured values is likely to have been the result of an instability of properties for the material or a difference in the measurement method. A dispersed catalyst fuel cell was fabricated and tested using a 150¼m thick HPA-based photocurable membrane (above, PolyPOM75v), exhibiting a current density of greater than 300mA/cm2 at 0.5V (H2/Air 800/1800sccm 70°C/75%RH ambient outlet pressure). Multiple lots of a co-polymer based on poly-trifluorovinylether (TFVE) derived HPA were synthesized and fabricated into films, Generation II films. These materials showed proton conductivities as high as 1 S/cm under high RH conditions. However, the materials suffered from compromised properties due to impure monomers and low molecular weights. Multiple lots of an HPA-immobilized fluoropolymer derived from preformed PVDF-HFP (Generation III films) were synthesized and formed into membranes at 3M and characterized at 3M to exhibit conductivity reaching approximately 75mS/cm at 120°C/40%RH using a Bekktech sample fixture and TestEquity oven (optimized membrane, at close of program). Initial fuel cell fabrication and testing for this new class of membrane yielded negative results (no measureable proton conductivity); however, the specific early membrane that was used for the two 5cm2 MEAs was later determined to have <1 mS/cm at 80°C/80%RH using the Bekktech fixture, vs. ca. 200 mS/cm at 80°C/80%RH for samples of the later-optimized type described above. Future work in this area (beyond the presently reported contract) should include additional attempts to fabricate and test fuel cells based on the later-optimized Generation II and III polymer. A manufacturing study was performed which predicted no difficulties in any future scale up of the materials.

Herring, Andrew M; Horan, James L; Aieta, Niccolo V; Sachdeva, Sonny; Kuo, Mei-Chen; Ren, Hui; Lingutla, Anitha; Emery, Michael; Haugen, Gregory M; Yandrasits, Michael A; Sharma, Neeraj; Coggio, William D; Hamrock, Steven J; Frey, Matthew H

2012-05-20T23:59:59.000Z

63

Polyimide Capacitive Humidity Sensors  

E-Print Network [OSTI]

to actiMta a switch are still widely used in residential a~plications. These humidity aontrollers an reliable anl trrublefree, but onnot be ansidered precision cmtmls because of variatiom in materials anl in manufacturing tolera~e~. In a...

Lofgren, H.; Mills, F.

1988-01-01T23:59:59.000Z

64

Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates  

E-Print Network [OSTI]

An experimental study was conducted to quantify the effect of return air leakage from hot/humid attic spaces on the performance of a residential air conditioner. Tests were conducted in psychrometric facilities where temperatures and humidities...

O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

1996-01-01T23:59:59.000Z

65

Evaluation of Humidity Control Options in Hot-Humid Climate Homes (Fact Sheet)  

SciTech Connect (OSTI)

This technical highlight describes NREL research to analyze the indoor relative humidity in three home types in the hot-humid climate zone, and examine the impacts of various dehumidification equipment and controls. As the Building America program researches construction of homes that achieve greater source energy savings over typical mid-1990s construction, proper modeling of whole-house latent loads and operation of humidity control equipment has become a high priority. Long-term high relative humidity can cause health and durability problems in homes, particularly in a hot-humid climate. In this study, researchers at the National Renewable Energy Laboratory (NREL) used the latest EnergyPlus tool equipped with the moisture capacitance model to analyze the indoor relative humidity in three home types: a Building America high-performance home; a mid-1990s reference home; and a 2006 International Energy Conservation Code (IECC)-compliant home in hot-humid climate zones. They examined the impacts of various dehumidification equipment and controls on the high-performance home where the dehumidification equipment energy use can become a much larger portion of whole-house energy consumption. The research included a number of simulated cases: thermostat reset, A/C with energy recovery ventilator, heat exchanger assisted A/C, A/C with condenser reheat, A/C with desiccant wheel dehumidifier, A/C with DX dehumidifier, A/C with energy recovery ventilator, and DX dehumidifier. Space relative humidity, thermal comfort, and whole-house source energy consumption were compared for indoor relative humidity set points of 50%, 55%, and 60%. The study revealed why similar trends of high humidity were observed in all three homes regardless of energy efficiency, and why humidity problems are not necessarily unique in the high-performance home. Thermal comfort analysis indicated that occupants are unlikely to notice indoor humidity problems. The study confirmed that supplemental dehumidification is needed to maintain space relative humidity (RH) below 60% in a hot-humid climate home. Researchers also concluded that while all the active dehumidification options included in the study successfully controlled space relative humidity excursions, the increase in whole-house energy consumption was much more sensitive to the humidity set point than the chosen technology option. In the high-performance home, supplemental dehumidification equipment results in a significant source energy consumption penalty at 50% RH set point (12.6%-22.4%) compared to the consumption at 60% RH set point (1.5%-2.7%). At 50% and 55% RH set points, A/C with desiccant wheel dehumidifier and A/C with ERV and high-efficiency DX dehumidifier stand out as the two cases resulting in the smallest increase of source energy consumption. At an RH set point of 60%, all explicit dehumidification technologies result in similar insignificant increases in source energy consumption and thus are equally competitive.

Not Available

2011-12-01T23:59:59.000Z

66

Humidity effects on wire insulation breakdown strength.  

SciTech Connect (OSTI)

Methods for the testing of the dielectric breakdown strength of insulation on metal wires under variable humidity conditions were developed. Two methods, an ASTM method and the twisted pair method, were compared to determine if the twisted pair method could be used for determination of breakdown strength under variable humidity conditions. It was concluded that, although there were small differences in outcomes between the two testing methods, the non-standard method (twisted pair) would be appropriate to use for further testing of the effects of humidity on breakdown performance. The dielectric breakdown strength of 34G copper wire insulated with double layer Poly-Thermaleze/Polyamide-imide insulation was measured using the twisted pair method under a variety of relative humidity (RH) conditions and exposure times. Humidity at 50% RH and below was not found to affect the dielectric breakdown strength. At 80% RH the dielectric breakdown strength was significantly diminished. No effect for exposure time up to 140 hours was observed at 50 or 80%RH.

Appelhans, Leah

2013-08-01T23:59:59.000Z

67

Proceedings: Electric dehumidification: State-of-the-art humidity control for supermarkets seminar  

SciTech Connect (OSTI)

On October 9--10 1990, EPRI sponsored a conference in New Orleans, Louisiana on Electric Dehumidification: State of the Art Humidity Control for Supermarkets. The conference was attended by 124 electric utility, manufacturer, supermarket industry and consultant representatives. Attendees heard 17 speakers address efficient electric technologies for controlling relative humidity, and the importance of humidity control in the supermarket environment. Speakers addressed efficient electric technologies as well as gas desiccant systems. The management of energy use in supermarkets is a complex task. Energy costs are a major part of the supermarket operating budget, and the supermarket business is one where small differences in operating costs can make the difference between profit and loss. Energy use is dominated by refrigeration and HVAC, and the control of energy costs is dependent on the successful management of the interaction between these two systems. Humidity control in supermarkets is critical because of the presence of refrigerated display cases. Excess humidity causes display case fixture sweating and refrigeration coil and product frosting, requires frequent defrosting, and increased energy use for antisweat heaters and refrigeration. The conventional approach to dehumidification in an all-electric system is overcooling to condense moisture and reheat to bring the air to a comfortable temperature. This approach, while effective in less demanding environments, results in high electric energy costs for the humidity control necessary in supermarkets. Speakers in the introductory session of the conference explained the importance of electric energy for the supermarket; discussed modern refrigeration systems; and set the stage for more detailed discussion of specific dehumidification systems.

Not Available

1992-10-01T23:59:59.000Z

68

Ultrahigh humidity sensitivity of graphene oxide  

E-Print Network [OSTI]

Humidity sensors have been extensively used in various fields, and numerous problems are encountered when using humidity sensors, including low sensitivity, long response and recovery times, and narrow humidity detection ...

Bi, Hengchang

69

Tower Temperature and Humidity Sensors (TWR) Handbook  

SciTech Connect (OSTI)

Three tall towers are installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility: a 60-meter triangular tower at the Southern Great Plains (SGP) Central Facility (CF), a 21-meter walkup scaffolding tower at the SGP Okmulgee forest site (E21), and a 40-meter triangular tower at the North Slope of Alaska (NSA) Barrow site. The towers are used for meteorological, radiological, and other measurements.

Cook, DR

2010-02-01T23:59:59.000Z

70

QA TG5 UV, temperature and humidity  

Broader source: Energy.gov (indexed) [DOE]

February 27, 11:00 11:15 Task-Force coordinated by: Michael Khl, Fraunhofer ISE, Germany michael.koehl@ise.fraunhofer.de Kusato Hirota, Toray Industries, Inc., Japan * Kusato...

71

Group 3: Humidity, Temperature, and Voltage  

Broader source: Energy.gov (indexed) [DOE]

lines, interconnect r ibbons, s older bonds) will likely corrode if exposed to liquid water. * So even if our contacts can survive moisture in the encapsulant they are n ot...

72

Comparing Wind, Temperature, Pressure, and Humidity  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation Proposed New SubstationCleanCommunity Involvement and MakingYersiniae.Shewanella genus .How

73

Temperature and pressure dependences of the Copper-related Green...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

(PL) from tetrapod-like ZnO micro-rods. The temperature dependence of the green emission energy follows the changes in the band gap from 10-200 K, but deviates from...

74

Ceramic thick film humidity sensor based on MgTiO{sub 3} + LiF  

SciTech Connect (OSTI)

Graphical abstract: - Highlights: • The fabricated sensor based on MgTiO{sub 3} + LiF materials used the spin coating technology. • The response time is 70 s to detect variation between 5 and 95% relative humidity. • The addition of Scleroglucan controls the viscosity and decreases the roughness of thick film surface. • This humidity sensor is a promising, low-cost, high-quality, reliable ceramic films, that is highly sensitive to humidity. - Abstract: The feasibility of humidity sensor, consisting of a thick layer of MgTiO{sub 3}/LiF materials on alumina substrate, was studied. The thermal analysis TGA-DTGA and dilatometric analysis worked out to confirm the sintering temperature. An experimental plan was applied to describe the effects of different parameters in the development of the thick film sensor. Structural and microstructural characterizations of the developed thick film were made. Rheological study with different amounts of a thickener (scleroglucan “sclg”), showing the behavior variation, as a function of sclg weight % was illustrated and rapprochement with the results of thickness variation as a function of angular velocity applied in the spin coater. The electrical and dielectric measurements confirmed the sensitivity of the elaborated thick film against moisture, along with low response time.

Kassas, Ahmad, E-mail: a.kassas.mcema@ul.edu.lb [Faculty of Agricultural Engineering and Veterinary Medicine, Laboratory of Materials, Catalysis, Environment and Analytical Methods (MCEMA), Faculty of Sciences and Doctoral School of Sciences and Technology (EDST), Lebanese University, Hariri Campus, Hadath, Beirut (Lebanon); Laboratoire Universitaire des Sciences Appliquées de Cherbourg (LUSAC), 50130 Cherbourg-Octeville (France); Bernard, Jérôme; Lelièvre, Céline; Besq, Anthony; Guhel, Yannick; Houivet, David; Boudart, Bertrand [Laboratoire Universitaire des Sciences Appliquées de Cherbourg (LUSAC), 50130 Cherbourg-Octeville (France); Lakiss, Hassan [Faculty of Agricultural Engineering and Veterinary Medicine, Laboratory of Materials, Catalysis, Environment and Analytical Methods (MCEMA), Faculty of Sciences and Doctoral School of Sciences and Technology (EDST), Lebanese University, Hariri Campus, Hadath, Beirut (Lebanon); Faculty of Engineering, Section III, Hariri Campus, Hadath, Beirut (Lebanon); Hamieh, Tayssir [Faculty of Agricultural Engineering and Veterinary Medicine, Laboratory of Materials, Catalysis, Environment and Analytical Methods (MCEMA), Faculty of Sciences and Doctoral School of Sciences and Technology (EDST), Lebanese University, Hariri Campus, Hadath, Beirut (Lebanon)

2013-10-15T23:59:59.000Z

75

Phase relation between global temperature and atmospheric carbon dioxide  

E-Print Network [OSTI]

The primary ingredient of Anthropogenic Global Warming hypothesis is the assumption that atmospheric carbon dioxide variations are the cause for temperature variations. In this paper we discuss this assumption and analyze it on basis of bi-centenary measurements and using a relaxation model which causes phase shifts and delays.

Stallinga, Peter

2013-01-01T23:59:59.000Z

76

Improving Comfort in Hot-Humid Climates with a Whole-House Dehumidifier, Windermere, Florida (Fact Sheet)  

SciTech Connect (OSTI)

Maintaining comfort in a home can be challenging in hot-humid climates. At the common summer temperature set point of 75 degrees F, the perceived air temperature can vary by 11 degrees F because higher indoor humidity reduces comfort. Often the air conditioner (AC) thermostat set point is lower than the desirable cooling level to try to increase moisture removal so that the interior air is not humid or "muggy." However, this method is not always effective in maintaining indoor relative humidity (RH) or comfort. In order to quantify the performance of a combined whole-house dehumidifier (WHD) AC system, researchers from the U.S. Department of Energy's Building America team Consortium of Advanced Residential Buildings (CARB) monitored the operation of two Lennox AC systems coupled with a Honeywell DH150 TrueDRY whole-house dehumidifier for a six-month period. By using a WHD to control moisture levels (latent cooling) and optimizing a central AC to control temperature (sensible cooling), improvements in comfort can be achieved while reducing utility costs. Indoor comfort for this study was defined as maintaining indoor conditions at below 60% RH and a humidity ratio of 0.012 lbm/lbm while at common dry bulb set point temperatures of 74 degrees -80 degrees F. In addition to enhanced comfort, controlling moisture to these levels can reduce the risk of other potential issues such as mold growth, pests, and building component degradation. Because a standard AC must also reduce dry bulb air temperature in order to remove moisture, a WHD is typically needed to support these latent loads when sensible heat removal is not desired.

Not Available

2013-11-01T23:59:59.000Z

77

Active Humidity Control Through Gas-Fired Desiccant Humidity Pump  

E-Print Network [OSTI]

to regenerate the desiccant. Field experiments of two humidity pumps on existing commercial buildings have been initiated. Each system dehumidifies 5000 scfm of make-up air to meet all the latent loads, which is then fed to conventional, electric-driven HVAC...

Novosel, D.; Griffiths, W. C.

1988-01-01T23:59:59.000Z

78

Effects of larval nutrition, relative humidity, and temperature on survival, rate of development, and fecundity of the bollworm, Heliothis zea (Boddie  

E-Print Network [OSTI]

). These authors noted that the ef f sct of' drought conditions on the crop may cause a high mortality among the developing insects. Pearson and Plax- well-Darling (1958) found that in AFrica the abundance or scarcity of squares and flowers serving as food... throughout the entire growing season pearson and Maxwell-Darling (1958) Pound that in Africa Heliothis spp. larvae fed on developing Pruits of a variety , - of crop plants with maize being particularly favored. A ?devastating bollworm attack might...

Fisher, Michael Kilpatrick

1968-01-01T23:59:59.000Z

79

Direct effects: Quantity related to precipitation Direct effects: Quantity related to precipitation and temperature  

E-Print Network [OSTI]

) Adequate and sufficient water supply: (storage, snow pack reservoir and groundwater levels)snow pack temperature extremes, heat waves and heavy precipitation. Precipitation increases in high latitudes and decreases in most sub-tropical land regions. Increases in annual river runoff and water availability

Fay, Noah

80

THE LOW-TEMPERATURE THRESHOLD FOR PINK SALMON EGGS IN RELATION TO A PROPOSED HYDROELECTRIC INSTALLATION  

E-Print Network [OSTI]

THE LOW-TEMPERATURE THRESHOLD FOR PINK SALMON EGGS IN RELATION TO A PROPOSED HYDROELECTRIC INSTALLATION JACK E. BAILEY' AND DALE R. EVANS' ABSTRACT A proposed hydroelectric installation in southeastern hydroelectric installation could result in temperatures as low as 4.5 0 C during spawning and initial incubation

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

The relative importance of deforestation, precipitation change, and temperature sensitivity in determining the  

E-Print Network [OSTI]

The relative importance of deforestation, precipitation change, and temperature sensitivity human disturbances ­ two of the most important of which are deforestation and climate change of deforestation as well as the response of species to changes in temperature, precipitation, and atmospheric

Malhi, Yadvinder

82

STATISTICAL METHODS FOR RELATING TEMPERATURE EXTREMES TO LARGE-SCALE METEOROLOGICAL PATTERNS  

E-Print Network [OSTI]

1 STATISTICAL METHODS FOR RELATING TEMPERATURE EXTREMES TO LARGE-SCALE METEOROLOGICAL PATTERNS Rick Extreme Value Analysis: Block Maxima (3) Conditional Extreme Value Analysis: Peaks over Threshold (4) Application to California Temperature Extremes (5) Remaining Work #12;3 #12;4 #12;5 (1) Introduction

Katz, Richard

83

Temperature effects on oil-water relative permeabilities for unconsolidated sands  

SciTech Connect (OSTI)

This study presents an experimental investigation of temperature effects on relative permeabilities of oil- water systems in unconsolidated sands. The fluids used in this study were refined mineral oil and distilled water. A rate sensitivity study was done on residual oil saturation and oil and water relative permeabilities. The temperature sensitivity study of relative permeabilities was conducted in 2 parts. The first was to investigate changes in residual oil saturation with temperature where the cores were 100% saturated with oil at the start of the waterflood. The second part continued the floods for a longer time until the water-cut was virtually 100%. Under these conditions, little change in residual oil saturation was observed with temperature. A study on viscous instabilities also was performed. This verified the existence of viscous fingers during waterflooding. It also was observed that tubing volume after the core could cause fingering, resulting in lower apparent breakthrough oil recoveries.

Sufi, A.H.

1983-03-01T23:59:59.000Z

84

CVEN 6960 master's project, investigation of a cooling coil in high humidity conditions. Master's thesis  

SciTech Connect (OSTI)

The primary purpose of this project is to validate the HVAC*2 Toolkit calculations for a cooling coil in high humidity conditions. A total of 19 experimental runs at different entering air temperature and humidity conditions were performed at the Joint Center for Energy Management HVAC Laboratory that exposed a cooling coil to temperature and humidity conditions that are typically found in the southern United States. The inlet conditions and manufacturer's coil rating data was used as input to the HVAC*2 Toolkit simple cooling coil subroutine (CCSIM). The predicted results from the toolkit were then compared to the experimental results.

Sloop, R.E.

1993-12-10T23:59:59.000Z

85

The importance of the glass transition temperature in relation to the low-temperature fracture resistance of asphalt and sulphlex pavement binders  

E-Print Network [OSTI]

THE IMPORTANCE DF THE GLASS TRANSITION TEMPERATURE IN RELATION TO THE LOW-TEMPERATURE FRACTURE RESISTANCE OF ASPHALT AND SULPHLEX PAVEMENT BINDERS A Thesis by DOUGLAS LEE SMITH Submitted to the Graduate College of Texas ASM University... of the Glass Transition Temperature in Relation to the Low-Temperature Fracture Resistance of Asphalt and Sulphlex Pavement Binders. (May 1985) Douglas Lee Smith, B. S. , Texas A&M University Chairman of Advisory Committee; Dr. Donald Saylak A quartz tube...

Smith, Douglas Lee

1985-01-01T23:59:59.000Z

86

Temperature-extended Jarzynski relation: Application to the numerical calculation of the surface tension  

E-Print Network [OSTI]

We consider a generalization of the Jarzynski relation to the case where the system interacts with a bath for which the temperature is not kept constant but can vary during the transformation. We suggest to use this relation as a replacement to the thermodynamic perturbation method or the Bennett method for the estimation of the order-order surface tension by Monte Carlo simulations. To demonstrate the feasibility of the method, we present some numerical data for the 3D Ising model.

Christophe Chatelain

2007-04-05T23:59:59.000Z

87

Phononic pairing glue in cuprates and related high-temperature superconductors  

E-Print Network [OSTI]

Along with some other researches we have realised that the true origin of high-temperature superconductivity should be found in the strong Coulomb repulsion combined with a significant electronphonon interaction. Both interactions are strong (on the order of 1 eV) compared with the low Fermi energy of doped carries which makes the conventional BCS-Eliashberg theory inapplicable in cuprates and related doped insulators. Based on our recent analytical and numerical results I argue that high-temperature superconductivity from repulsion is impossible for any strength of the Coulomb interaction. Major steps of our alternative polaronic theory are outlined starting from the generic Hamiltonian with the unscreened (bare) Coulomb and electron-phonon interactions accounting for critical temperatures of high-temperature superconductors without any adjustable parameters.

A. S. Alexandrov

2011-12-16T23:59:59.000Z

88

Temperature effects on oil-water relative permeabilities for unconsolidated sands  

SciTech Connect (OSTI)

This study presents an experimental investigation of temperature effects on relative permeabilities of oil-water systems in unconsolidated sands. The fluids used in this study were refined mineral oil and distilled water. A rate sensitivity study was done on residual oil saturation (S/sub or/) and oil and water relative permeabilities. The temperature sensitivity study of relative permeabilities was conducted in two parts. The first was to investigate changes in S/sub or/ with temperature where the cores were 100% saturated with oil at the start of the waterflood. Runs were terminated when the water-cut exceeded 99.8%. For these experiments, S/sub or/ decreased from 0.31 at 70/sup 0/F to 0.09 at 250/sup 0/F. The second part continued the floods for a longer time until the water-cut was virtually 100%. Under these conditions, little change in S/sub or/ was observed with temperature; (0.11 at 70/sup 0/F and 0.085 at 186/sup 0/F). Temperature effects on irreducible water saturations were studied. A small increase in irreducibile water saturation was observed upon increasing the temperature. However, the same magnitude of change was observed by changing the flowrate. Upon increasing the oil flowrate, immediate water production was observed from the core indicating a change in the capillary end effect. By comparing the change in irreducible water saturation with rate and temperature, it was determined that the change was caused mainly by a change in the viscous force across the core. A study on viscous instabilities was also performed. This verified the existence of viscous fingers during waterflooding. It was also observed that tubing volume after the core could cause fingering, resulting in lower apparent breakthrough oil recoveries.

Sufi, A.H.

1982-01-01T23:59:59.000Z

89

Test Plan to Evaluate the Relationship Among IAQ, Comfort, Moisture, and Ventilation in Humid Climates  

SciTech Connect (OSTI)

This experimental plan describes research being conducted by Pacific Northwest National Laboratory (PNNL), in coordinatation with Florida Solar Energy Center (FSEC), Florida HERO, and Lawrence Berkeley National Laboratory (LBNL) to evaluate the impact of ventilation rate on interior moisture levels, temperature distributions, and indoor air contaminant concentrations. Specifically, the research team will measure concentrations of indoor air contaminants, ventilation system flow rates, energy consumption, and temperature and relative humidity in ten homes in Gainesville, FL to characterize indoor pollutant levels and energy consumption associated with the observed ventilation rates. PNNL and FSEC have collaboratively prepared this experimental test plan, which describes background and context for the proposed study; the experimental design; specific monitoring points, including monitoring equipment, and sampling frequency; key research questions and the associated data analysis approach; experimental logistics, including schedule, milestones, and team member contact information; and clearly identifies the roles and responsibilities of each team in support of project objectives.

Widder, Sarah H.; Martin, Eric

2013-03-15T23:59:59.000Z

90

An empirical expression to relate aerodynamic and surface temperatures for use within1 single-source energy balance models2  

E-Print Network [OSTI]

1 n.1 An empirical expression to relate aerodynamic and surface temperatures for use within1 single that the14 reference temperature for the estimation of convective fluxes, the aerodynamic temperature, is15 between the aerodynamic22 and the air temperatures and the difference between the surface and the air

Paris-Sud XI, Université de

91

EFFECT OF HUMIDITY LEVEL ON THE CREEP PROPERTIES OF ALLOY 903 AT 650 C  

SciTech Connect (OSTI)

Alloy 903 (FeNiCo+Nb) is currently used for certain components in industrial gas turbines for low coefficient of thermal expansion applications. A variance in creep behavior for material quality control evaluations suggested a possible effect of moisture level on stress rupture properties. To investigate the role of water vapor on the creep properties of alloy 903, controlled laboratory experiments were conducted at 650 C with 0 to 100% relative humidity. The water content was controlled by flowing dry air through a water bath at a constant temperature. A significant decrease of lifetime was observed in the presence of water vapor, which is likely related to grain boundary embrittlement by the inward diffusion of hydrogen. The increase of the microstructure grain aspect ratio by different forging processes generally improved the rupture lifetime and elongation in air. However, all specimens had reduced lifetime in the presence of water vapor despite the microstructure grain aspect ratios.

Dryepondt, Sebastien N [ORNL; Pint, Bruce A [ORNL; Mitchell, Ryan D [Solar Turbines, Inc.

2012-01-01T23:59:59.000Z

92

Problems associated with the use of urea-formaldehyde foam for residential insulation. Part II. The effects of temperature and humidity on free formaldehyde, extractable formaldehyde, formaldehyde emission, and physical characteristics of the foam  

SciTech Connect (OSTI)

Results of testing with two products of urea-formaldehyde based foams are described. Results of three products have previously been reported. Methods for detection and quantitative determination of formaldehyde, design of the experimental chambers, and the procedures are described. Samples of Product D were monitored for about 29 days and samples of Product E were monitored for 60 days in chambers and results are tabulated for formaldehyde emission. Additional tests performed on the two products are: extractable formaldehyde (high and low temperature conditions); free formaldehyde (high and low temperature conditions); comparison of free formaldehyde concentration; density (high and low temperature conditions); shrinkage (high and low temperature conditions). Control panels were constructed to simulate a wall in a home and observations were made and compared with results of the experimental products.

Schutte, W.C.; Cole, R.S.; Frank, C.W.; Long, K.R.

1981-02-01T23:59:59.000Z

93

MHTGR (modular high-temperature gas-cooled reactor) control: A non-safety related system  

SciTech Connect (OSTI)

The modular high-temperature gas-cooled reactor (MHTGR) design meets stringent top-level safety regulatory criteria and user requirements that call for high plant availability and no disruption of the public's day to day activities during normal and off-normal operation of the plant. These requirements lead to a plant design that relies mainly on physical properties and passive design features to ensure plant safety regardless of operator actions, plus simplicity and automation to ensure high plant availability and lower cost of operations. The plant does not require safety-related operator actions, and it does not require the control room to be safety related.

Rodriguez, C.; Swart, F.

1988-06-01T23:59:59.000Z

94

Building America Expert Meeting: Recommended Approaches to Humidity...  

Energy Savers [EERE]

Building America Expert Meeting: Recommended Approaches to Humidity Control in High Performance Homes Building America Expert Meeting: Recommended Approaches to Humidity Control in...

95

Infrared behavior of the dispersion relations in high-temperature scalar QED  

E-Print Network [OSTI]

We investigate the infrared properties of the next-to-leading-order dispersion relations in scalar quantum electrodynamics at high temperature in the context of hard-thermal-loop perturbation theory. Specifically, we determine the damping rate and the energy for scalars with ultrasoft momenta. We show by explicit calculations that an early external-momentum expansion, before the Matsubara sum is performed, gives exactly the same result as a late one. The damping rate is obtained up to fourth order included in the ultrasoft momentum and the energy up to second order. The damping rate is found sensitive in the infrared whereas the energy not.

A. Abada; K. Bouakaz

2005-10-25T23:59:59.000Z

96

HUMID AIR TURBINE CYCLE TECHNOLOGY DEVELOPMENT PROGRAM  

SciTech Connect (OSTI)

The Humid Air Turbine (HAT) Cycle Technology Development Program focused on obtaining HAT cycle combustor technology that will be the foundation of future products. The work carried out under the auspices of the HAT Program built on the extensive low emissions stationary gas turbine work performed in the past by Pratt & Whitney (P&W). This Program is an integral part of technology base development within the Advanced Turbine Systems Program at the Department of Energy (DOE) and its experiments stretched over 5 years. The goal of the project was to fill in technological data gaps in the development of the HAT cycle and identify a combustor configuration that would efficiently burn high moisture, high-pressure gaseous fuels with low emissions. The major emphasis will be on the development of kinetic data, computer modeling, and evaluations of combustor configurations. The Program commenced during the 4th Quarter of 1996 and closed in the 4th Quarter of 2001. It teamed the National Energy Technology Laboratory (NETL) with P&W, the United Technologies Research Center (UTRC), and a subcontractor on-site at UTRC, kraftWork Systems Inc. The execution of the program started with bench-top experiments that were conducted at UTRC for extending kinetic mechanisms to HAT cycle temperature, pressure, and moisture conditions. The fundamental data generated in the bench-top experiments was incorporated into the analytical tools available at P&W to design the fuel injectors and combustors. The NETL then used the hardware to conduct combustion rig experiments to evaluate the performance of the combustion systems at elevated pressure and temperature conditions representative of the HAT cycle. The results were integrated into systems analysis done by kraftWork to verify that sufficient understanding of the technology had been achieved and that large-scale technological application and demonstration could be undertaken as follow-on activity. An optional program extended the experimental combustion evaluations to several specific technologies that can be used with HAT technology. After 5 years of extensive research and development, P&W is pleased to report that the HAT Technology Development Program goals have been achieved. With 0 to 10 percent steam addition, emissions achieved during this program featured less than 8 ppm NO{sub x}, less than 16 ppm CO, and unburned hydrocarbons corrected to 15 percent O{sub 2} for an FT8 engine operating between 0 and 120 F with 65 to 100 percent power at any day.

Richard Tuthill

2002-07-18T23:59:59.000Z

97

Lanthanide-halide based humidity indicators  

DOE Patents [OSTI]

The present invention discloses a lanthanide-halide based humidity indicator and method of producing such indicator. The color of the present invention indicates the humidity of an atmosphere to which it is exposed. For example, impregnating an adsorbent support such as silica gel with an aqueous solution of the europium-containing reagent solution described herein, and dehydrating the support to dryness forms a substance with a yellow color. When this substance is exposed to a humid atmosphere the water vapor from the air is adsorbed into the coating on the pore surface of the silica gel. As the water content of the coating increases, the visual color of the coated silica gel changes from yellow to white. The color change is due to the water combining with the lanthanide-halide complex on the pores of the gel.

Beitz, James V. (Hinsdale, IL); Williams, Clayton W. (Chicago, IL)

2008-01-01T23:59:59.000Z

98

Variation in rectal temperature, respiratory rate, and pulse rate of cattle as related to variations in solar radiation, air temperature, wind velocity, and vapor pressure  

E-Print Network [OSTI]

VARIATION IN RECTAL TEMPERATURE, RESPIRATORY RATE, AND PULSE RATE GF CATTLE AS RELATED TO VARIATIONS IN SOLAR RADIATION, AIR TEMPERATURE, WIND VELOCITY, AND VAPOR PRESSURE A Dissertation By Mohammad Fazlur Rahim Quazi Approved as to style... Dissertation By Mohammad Fazlur Rahim tyiazi Submitted to the Graduate School of the Agricultural and Mechanical College of Texas in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY May 1955 Major Subject: Genetics ? ?4...

Quazi, Mohammad Fazlur Rahim

1955-01-01T23:59:59.000Z

99

Voltage sensing systems and methods for passive compensation of temperature related intrinsic phase shift  

DOE Patents [OSTI]

A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. In crystals that introduce a phase differential attributable to temperature, a compensating crystal is provided to cancel the effect of temperature on the phase differential of the input beam. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

Davidson, James R. (Idaho Falls, ID); Lassahn, Gordon D. (Idaho Falls, ID)

2001-01-01T23:59:59.000Z

100

Corrosion product identification and relative rates of corrosion of candidate metals in an irradiated air-steam environment  

SciTech Connect (OSTI)

Previously reported work by others indicates that dicopper trihydroxide nitrate, Cu{sub 2}NO{sub 3}(OH){sub 3}, forms on copper and copper alloys subjected to irradiated moist air near room temperature. We have performed experiments over a range of temperature and humidity, and have found that this species is formed at temperatures up to at least 150{degree}C if low to intermediate relative humidities are present. At 150{degree}C and 100% relative humidity, only Cu{sub 2}O and CuO were observed. The relative general corrosion rates of the copper materials tested in 1-month experiments at dose rates of 0.7 and 2.0 kGy/h were Cu > 70/30 Cu--Ni > Al-bronze. High-nickel alloy 825 showed no observable corrosion. 29 refs., 4 tabs.

Reed, D.T.; Swayambunathan, V.; Tani, B.S. (Argonne National Lab., IL (USA)); Van Konynenburg, R.A. (Lawrence Livermore National Lab., CA (USA))

1989-11-03T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Response of tropical sea surface temperature, precipitation, and tropical cyclone-related variables to changes in global and local forcing  

E-Print Network [OSTI]

A single-column model is used to estimate the equilibrium response of sea surface temperature (SST), precipitation, and several variables related to tropical cyclone (TC) activity to changes in both local and global forcing. ...

Sobel, Adam

102

Vertical distribution of larval stages of the horn fly, Haematobia irritans irritans (L.), in relation to manure pat temperature gradients  

E-Print Network [OSTI]

VERTICAL DISTRISUTION OF LARVAL STAGES OF THE HORN FLY, HAEMATOBIA IRRITANS IRRITANS (L. ), IN RELATION TO MANURE PAT TEMPERATURE GRADIENTS A Thesis by PHILIP ANDERSON MARCH Submitted to the Graduate College of Texas AijM University... in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE May 1981 Major Subject: Entomology VERTICAL DISTRIBUTION OF LARVAL STAGES OF THE HORN FLY, HAEMATOBIA IRRITANS IRRITANS (L. ), IN RELATION TO MANURE PAT TEMPERATURE GRADIENTS...

March, Philip Anderson

1981-01-01T23:59:59.000Z

103

Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles  

E-Print Network [OSTI]

temperature at supply air temperature setpoint. Mechanical cooling is always required when outside air temperature is higher than the supply air temperature setpoint. Generally the supply air temperature setpoint is set at 55°F for space humidity control...

Xu, K.; Liu, M.; Wang, G.; Wang, Z.

2007-01-01T23:59:59.000Z

104

Coil Condensation Detection For Humidity Control  

E-Print Network [OSTI]

of an enthalpy economizer. A spreadsheet simulation of enthalpy economizer use showed that the savings available are heavily dependent on the ability to avoid its use on very hot, humid days. A newly-designed condensation sensor was developed for this project...

Kaneb, Charles Peckitt

2014-05-12T23:59:59.000Z

105

Data Center Economizer Contamination and Humidity Study  

E-Print Network [OSTI]

and potential loss of humidity control. Concerns about equipment failure from airborne pollutants lead 42 #12;Executive Summary Data centers require continuous air conditioning to address high internal levels for computers. Air economizer cycles, which bring in large amounts of outside air to cool internal

106

The effect of temperature and humidity on respirator fit  

E-Print Network [OSTI]

Industry Standards. 2. ) ANSI 288. 2 (1980). 3. ) (NIOSH/MSHA) Title 3OCFR Part II. III. Respirator selection: 1. ) Proper device for the specific hazard. 2. ) Limitations of the device. IV. Fit test methods: 1. ) Negative Pressure. 2. ) Positive... respirator fit testing with isoamyl acetate (banana oil) is used extensively by industry to comply with current Federal safety and health standards. This test is required to help ensure that the respirator's integrity is not reduced by an improper fit...

Niekerk, Gary

1986-01-01T23:59:59.000Z

107

Main-Sequence Effective Temperatures from a Revised Mass-Luminosity Relation Based on Accurate Properties  

E-Print Network [OSTI]

The mass-luminosity (M-L), mass-radius (M-R) and mass-effective temperature ($M-T_{eff}$) diagrams for a subset of galactic nearby main-sequence stars with masses and radii accurate to $\\leq 3\\%$ and luminosities accurate to $\\leq 30\\%$ (268 stars) has led to a putative discovery. Four distinct mass domains have been identified, which we have tentatively associated with low, intermediate, high, and very high mass main-sequence stars, but which nevertheless are clearly separated by three distinct break points at 1.05, 2.4, and 7$M_{\\odot}$ within the mass range studied of $0.38-32M_{\\odot}$. Further, a revised mass-luminosity relation (MLR) is found based on linear fits for each of the mass domains identified. The revised, mass-domain based MLRs, which are classical ($L \\propto M^{\\alpha}$), are shown to be preferable to a single linear, quadratic or cubic equation representing as an alternative MLR. Stellar radius evolution within the main-sequence for stars with $M>1M_{\\odot}$ is clearly evident on the M-R d...

Eker, Z; Soydugan, E; Bilir, S; Gokce, E Yaz; Steer, I; Tuysuz, M; Senyuz, T; Demircan, O

2015-01-01T23:59:59.000Z

108

Correlating Humidity-Dependent Ionically Conductive Surface Area with Transport Phenomena in Proton-Exchange Membranes  

SciTech Connect (OSTI)

The objective of this effort was to correlate the local surface ionic conductance of a Nafion? 212 proton-exchange membrane with its bulk and interfacial transport properties as a function of water content. Both macroscopic and microscopic proton conductivities were investigated at different relative humidity levels, using electrochemical impedance spectroscopy and current-sensing atomic force microscopy (CSAFM). We were able to identify small ion-conducting domains that grew with humidity at the surface of the membrane. Numerical analysis of the surface ionic conductance images recorded at various relative humidity levels helped determine the fractional area of ion-conducting active sites. A simple square-root relationship between the fractional conducting area and observed interfacial mass-transport resistance was established. Furthermore, the relationship between the bulk ionic conductivity and surface ionic conductance pattern of the Nafion? membrane was examined.

He, Qinggang; Kusoglu, Ahmet; Lucas, Ivan T.; Clark, Kyle; Weber, Adam Z.; Kostecki, Robert

2011-08-01T23:59:59.000Z

109

Exploring Maximum Humidity Control and Energy Conservation Opportunities with Single Duct Single Zone Air-Handling Units  

E-Print Network [OSTI]

Humidity control for single-duct single-zone (SDSZ) constant volume air handling units is known to be a challenge. The operation of these systems is governed by space temperature only. Under mild weather conditions, discharge air temperature can get...

Zhou, J.; Wei, G.; Turner, W. D.; Deng, S.; Claridge, D.

2006-01-01T23:59:59.000Z

110

Prediction of spring subterranean termite swarms in Texas with relation to temperature and precipitation  

E-Print Network [OSTI]

Research was conducted in order to determine predictive correlations among temperature (heat units), precipitation, and springtime subterranean termite swarming in Texas. Heat units were accumulated from December 21 through the date of the initial...

Furman, Barry Daine

2000-01-01T23:59:59.000Z

111

An Analytical Model for Tropical Relative Humidity DAVID M. ROMPS  

E-Print Network [OSTI]

the distribution of water vapor will change with warming. Water vapor is the atmosphere's most powerful greenhouse gas, and changes in its distribution can have significant implications for radiative forcing. A first

Romps, David M.

112

PDO-Related Heat and Temperature Budget Changes in a Model of the North Pacific JORDAN T. DAWE  

E-Print Network [OSTI]

in the Pacific. The PDO index shows significant correlations with a wide variety of climate indices, including between a variety of Indian and Pacific tropical climate indices and the PDO. Since atmospheric signalsPDO-Related Heat and Temperature Budget Changes in a Model of the North Pacific JORDAN T. DAWE

Thompson, LuAnne

113

Effect of Humidity on the Composition of Isoprene Photooxidation Secondary Organic Aerosol  

SciTech Connect (OSTI)

The effect of relative humidity (RH) on the composition and concentrations of gas-phase products and secondary organic aerosol (SOA) generated from the photooxidation of isoprene under high-NOx conditions was investigated. The yields of most gas-phase products were the same regardless of initial water vapor concentration with exception of hydroxyacetone and glycolaldehyde, which were considerably affected by RH. A significant change was observed in the SOA composition, with many unique condensed-phase products formed under humid (90% RH) vs. dry (<2% RH) conditions, without any observable effect on the rate and extent of the SOA mass growth.

Nguyen, Tran B.; Roach, Patrick J.; Laskin, Julia; Laskin, Alexander; Nizkorodov, Serguei

2011-07-18T23:59:59.000Z

114

Moisture performance of sealed attics in the mixed-humid climate  

SciTech Connect (OSTI)

Oak Ridge National Laboratory studied 8 homes in the mixed-humid climate, 4 with vented attics and 4 with sealed attics. ORNL wanted to understand the moisture performance of the sealed attic and how it affected the interior environment. We found that the attic and interior of sealed attic homes were more humid than the attic and interior observed in vented attic homes. This is due to the lack of ventilation in the sealed attic. Historically attics have been vented to dehumidify the attic and interior of the home. A sealed attic design greatly reduces the venting potential and thus this drying pathway and can cause elevated interior moisture over a vented attic home. Despite the elevated attic and interior moisture in the sealed attic homes, so far no mold or material degradation has been found. The roof sheathing moisture content has stayed below 20%, indicating low potential for material degradation. Also the relative humidity at the roof sheathing has stayed within the ASHRAE 160 design criteria except for a short time during the 2011/2012 winter. This was due to a combination of the sealed attic design (minimal venting to the outside) and the duct work not being operated in the attic which usually provides a dehumidification pathway. It was also found that when the humidity was controlled using the HVAC system, it resulted in 7% more cooling energy consumption. In the mixed-humid climate this reduces the cost effectiveness of the sealed attic design as a solution for bringing ducts into a semi-conditioned space. Because of this we are recommending the other alternatives be used to bringing ducts into the conditioned space in both new construction and retrofit work in the mixed-humid climate.

Boudreaux, Philip R [ORNL; Pallin, Simon B [ORNL; Jackson, Roderick K [ORNL

2013-12-01T23:59:59.000Z

115

Electric Field and Humidity Trigger Contact Electrification  

E-Print Network [OSTI]

Here, we study the old problem of why identical insulators can charge one another on contact. We perform several experiments showing that, if driven by a preexisting electric field, charge is transferred between contacting insulators. This happens because the insulator surfaces adsorb small amounts of water from a humid atmosphere. We believe the electric field then separates positively from negatively charged ions prevailing within the water, which we believe to be hydronium and hydroxide ions, such that at the point of contact, positive ions of one insulator neutralize negative ions of the other one, charging both of them. This mechanism can explain for the first time the observation made four decades ago that wind-blown sand discharges in sparks if and only if a thunderstorm is nearby.

Zhang, Yanzhen; Liu, Yonghong; Wang, Xiaolong; Zhang, Rui; Shen, Yang; Ji, Renjie; Cai, Baoping

2015-01-01T23:59:59.000Z

116

Electric Field and Humidity Trigger Contact Electrification  

E-Print Network [OSTI]

Here, we study the old problem of why identical insulators can charge one another on contact. We perform several experiments showing that, if driven by a preexisting electric field, charge is transferred between contacting insulators. This happens because the insulator surfaces adsorb small amounts of water from a humid atmosphere. We believe the electric field then separates positively from negatively charged ions prevailing within the water, which we believe to be hydronium and hydroxide ions, such that at the point of contact, positive ions of one insulator neutralize negative ions of the other one, charging both of them. This mechanism can explain for the first time the observation made four decades ago that wind-blown sand discharges in sparks if and only if a thunderstorm is nearby.

Yanzhen Zhang; Thomas Pähtz; Yonghong Liu; Xiaolong Wang; Rui Zhang; Yang Shen; Renjie Ji; Baoping Cai

2015-01-14T23:59:59.000Z

117

R&D on an Ultra-Thin Composite Membrane for High-Temperature Operation in PEMFC. Final Report  

SciTech Connect (OSTI)

FuelCell Energy developed a novel high-temperature proton exchange membrane for PEM fuel cells for building applications. The laboratory PEM fuel cell successfully operated at 100-400{supdegree}C and low relative humidity to improve CO tolerance, mitigate water and thermal management challenges, and reduce membrane cost. The developed high-temperature membrane has successfully completed 500h 120C endurance testing.

Yuh, C.-Y.

2003-10-06T23:59:59.000Z

118

Can ASHRAE Standard 62-1989 Requirements be Satisfied while Maintaining Moisture Control using Stock HVAC Equipment in Hot, Humid Climates?  

E-Print Network [OSTI]

energy costs. Increased ventilation rates create real capital and operating costs for building owners and operators, with implications beyond energy costs relating to increased ventilation requirements. In hot, humid climates, increased ventilation rates...

Turner, S. C.

1996-01-01T23:59:59.000Z

119

AC System Equipment Specification, Installation and Operational Options for Improved Indoor Humidity Control  

E-Print Network [OSTI]

of 80?F (26.7?C) dry-bulb temperature and 67?F (19.4?C) wet-bulb temperature air entering the indoor unit (AHRI 2006), the equipment SHRs range from 0.67 to 0.8. Thus, the dehumidification fraction (one minus SHR) varies from 0.2 (20%) to 0.33 (33... Building Systems in Hot and Humid Climates, Plano, TX, December 15-17, 2008 Figure 3. Latent Capacity Degradation with Supply Air Fan Overrun at Reduced Air Flow compressor on cycle (Shirey et al. 2006). The plotted lines are results from a...

Shirey, D. B.

120

Three Case Studies: Moisture Control in a Hot, Humid Climate  

E-Print Network [OSTI]

as analysis of the problems, and recommendations for correction. Each of these projects would be classified an airconditioned building in a hot, humid climate, and subject to the problems and design issues concomitant with these types of projects. The first...

French, W. R.

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

A tropical grammar : an architectural grammar for hot humid climates  

E-Print Network [OSTI]

This thesis considers the viability of an architectural grammar based on traditional Caribbean architecture as an aid to designing climatically responsive architecture in hot humid climates. It argues that since traditional ...

Beamish, Anne, 1954-

1993-01-01T23:59:59.000Z

122

argentine humid pampa: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

XI, Universit de 197 Humidity effects on ,,001... BaTiO3 single crystal surface water adsorption L. J. Qiao,1,a Engineering Websites Summary: with kinetic cutoff energy...

123

Effect of Humidity on the Composition of Isoprene Photooxidation...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

effect on the rate and extent of the SOA mass growth. Citation: Nguyen TB, PJ Roach, J Laskin, A Laskin, and S Nizkorodov.2011."Effect of Humidity on the Composition of...

124

PRESERVATION OF H2 PRODUCTION ACTIVITY IN NANOPOROUS LATEX COATINGS OF RHODOPSEUDOMONAS PALUSTRIS CGA009 DURING DRY STORAGE AT AMBIENT TEMPERATURES  

SciTech Connect (OSTI)

To assess the applicability of latex cell coatings as an "off-the-shelf' biocatalyst, the effect of osmoprotectants, temperature, humidity and O{sub 2} on preservation of H{sub 2} production in Rhodopseudomonas palustris coatings was evaluated. Immediately following latex coating coalescence (24 h) and for up to 2 weeks of dry storage, rehydrated coatings containing different osmoprotectants displayed similar rates of H{sub 2} production. Beyond 2 weeks of storage, sorbitol- treated coatings lost all H{sub 2} production activity, whereas considerable H{sub 2} production was still detected in sucrose- and trehalose-stabilized coatings. The relative humidity level at which the coatings were stored had a significant impact on the recovery and subsequent rates of H{sub 2} production. After 4 weeks storage under air at 60% humidity, coatings produced only trace amounts of H{sub 2} (0-0.1% headspace accumulation), whereas those stored at <5% humidity retained 27-53% of their H{sub 2} production activity after 8 weeks of storage. When stored in argon at <5% humidity and room temperature, R. palustris coatings retained full H{sub 2} production activity for 3 months, implicating oxidative damage as a key factor limiting coating storage. Overall, the results demonstrate that biocatalytic latex coatings are an attractive cell immobilization platform for preservation of bioactivity in the dry state.

Milliken, C.; Piskorska, M.; Soule, T.; Gosse, J.; Flickinger, M.; Smith, G.; Yeager, C.

2012-08-27T23:59:59.000Z

125

american temperature record: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

temperature, pressure, cloud, humidity and wind. The calibrated soil temperature data recorded at 1 foot30 cm and 4 foot100 cm depth 125 Call for Papers NEW Graduate...

126

Humidity effects on tip-induced polarization switching in lithium niobate  

SciTech Connect (OSTI)

In the last several decades, ferroelectrics have attracted much attention as perspective materials for nonlinear optics and data storage devices. Scanning probe microscopy (SPM) has emerged as a powerful tool both for studies of domain structures with nanoscale spatial resolution and for writing the isolated nanodomains by local application of the electric field. Quantitative analysis of the observed behavior requires understanding the role of environmental factors on imaging and switching process. Here we study the influence of the relative humidity in the SPM chamber on tip-induced polarization switching. The observed effects are attributed to existence of a water meniscus between the tip and the sample surface in humid atmosphere. These results are important for a deeper understanding of complex investigations of ferroelectric materials and their applications, and suggest the necessity for fundamental studies of electrocapillary phenomena at the tip-surface junction and their interplay with bias-induced materials responses.

Ievlev, Anton [ORNL] [ORNL; Morozovska, A. N. [National Academy of Science of Ukraine, Kiev, Ukraine] [National Academy of Science of Ukraine, Kiev, Ukraine; Shur, Vladimir Ya. [Ural Federal University, Russia] [Ural Federal University, Russia; Kalinin, Sergei V [ORNL] [ORNL

2014-01-01T23:59:59.000Z

127

Relationalism  

E-Print Network [OSTI]

This article contributes to the debate of the meaning of relationalism and background independence, which has remained of interest in theoretical physics from Newton versus Leibniz through to foundational issues for today's leading candidate theories of quantum gravity. I contrast and compose the substantially different Leibniz--Mach--Barbour (LMB) and Rovelli--Crane (RC) uses of the word `relational'. Leibniz advocated primary timelessness and Mach that `time is to be abstracted from change'. I consider 3 distinct viewpoints on Machian time: Barbour's, Rovelli's and my own. I provide four expansions on Barbour's taking configuration space to be primary: to (perhaps a weakened notion of) phase space, categorizing, perspecting and propositioning. Categorizing means considering not only object spaces but also the corresponding morphisms and then functors between such pairs. Perspecting means considering the set of subsystem perspectives; this is an arena in which the LMB and Rovelli approaches make contact. By propositioning, I mean considering the set of propositions about a physical (sub)system. I argue against categorization being more than a formal pre-requisite for quantization in general; however, perspecting is a categorical operation, and propositioning leads one to considering topoi, with Isham and Doering's work represents one possibility for a mathematically sharp implementation of propositioning. Further applications of this article are arguing for Ashtekar variables as being relational in LMB as well as just the usually-ascribed RC sense, relationalism versus supersymmetry, string theory and M-theory. The question of whether scale is relational is also considered, with quantum cosmology in mind.

Edward Anderson

2014-07-15T23:59:59.000Z

128

Shut Down Schedule Optimization with Outdoor Humidity Level  

E-Print Network [OSTI]

areas such as Portland and San Diego exhibit a large amount of hours wherein this scheme could be implemented. Table 4. Number of Hours That Satisfy AHU Shutdown Criteria for 16 U.S. Cities Hours that Fit All Three Criteria Location Total Hours... 6155 3055 886 3941 San Diego 6317 3331 853 4184 Portland 7167 3544 1035 4579 For hot and humid climates, such as Houston, the air is often too humid in the summer, and the methodology will work best during the fall, spring, and winter as seen...

Chen, H.; Deng, S.; Turner, W. D.; Claridge, D. E.; Clingenpeel, K.

2006-01-01T23:59:59.000Z

129

What Global Warming Looks Like The July 2010 global map of surface temperature anomalies (Figure 1), relative to the average  

E-Print Network [OSTI]

What Global Warming Looks Like The July 2010 global map of surface temperature anomalies (Figure 1 anomalies an example of what we can expect global warming to look like? Maps of temperature anomalies, such as Figure 1, are useful for helping people understand the role of global warming in extreme events

130

Internal Microclimate Resulting From Ventilated Attics in Hot and Humid Regions  

E-Print Network [OSTI]

, in multiple positions at the ridge vent, and three other locations along the roof decking of the attic. The placement of some of the various sensors can be seen in Figure 2. Data were recorded every 15 minutes for the entire year. During... S Roof Sub Shingle - Upper 0 50 100 150 200 250 Ho ur s ESL-HH-10-08-10 4 Figure 5. Monthly averages of relative humidity at various points The data collected in this study offer a complete view of the average microclimatic...

Mooney, B. L.; Porter, W. A.

131

Environmental conditions and responses of circus elephants transported by truck and railcar during relatively high and low temperatures  

E-Print Network [OSTI]

, and solar radiation were continuously measured during both extremes. Concentrations of ammonia and carbon monoxide during transport were also determined. Body temperature from a sample of elephants for each circus or exhibitor was also measured...

Toscano, Michael Jeffrey

2001-01-01T23:59:59.000Z

132

Corrosion-induced degradation of GaAs PHEMTs under operation in high humidity conditions  

E-Print Network [OSTI]

We have comprehensively investigated the degradation mechanism of AlGaAs/InGaAs pseudomorphic high-electron-mobility transistors (PHEMTs) under operation in high humidity conditions. PHEMTs degradation under high humidity ...

Hisaka, Takayuki

133

ASSESSMENT OF THE EFFECTIVENESS AND ENERGY EFFICIENCY OF HUMIDITY CONTROL APPROACHES IN VACANT FLORIDA HOMES  

E-Print Network [OSTI]

In a hot and humid climate such as Florida, “snowbirds” that leave their homes for extended summer periods need guidance on effective and energy efficient methods of humidity control. Experiments were performed in seven residences to evaluate...

Cummings, J. B.; Withers, C. R.

134

Building for the Pacific Rim Countries. Energy-efficient building strategies for hot, humid climates  

SciTech Connect (OSTI)

This book has been published by the Solar Energy Industries Association (SEIA), the US trade association of the solar thermal, photovoltaic, and passive solar manufacturers, distributors, and component suppliers. Its purpose is to help architects, builders, and developers construct energy-efficient homes in hot humid climates like the Pacific Rim Countries, and to allow occupants of these homes to enjoy enhanced comfort without reliance on mechanical air-conditioning systems. Two important factors are addressed in this book. First, the past few years have seen a tremendous increase in practical applications of new research. The current popularity of ceiling paddle fans, attic radiant barriers and natural daylighting attest to the importance of keeping up with the latest concepts in energy-reduction and comfort-awareness. Professionals who have been in the field for the past few years may be unaware of the latest research findings--some of which dramatically alter prior thinking on such subjects as natural ventilation or mechanical air conditioning. The second factor is the importance of site-specific characteristics, which greatly affect building strategies and designs. A thorough understanding of the climate is a prerequisite to good building design. Such factors as temperature, humidity, wind speed and direction, and solar radiation must be understood and properly integrated into the design for the home to be truly energy-efficient.

Sheinkopf, K. [ed.

1991-09-01T23:59:59.000Z

135

Performance Evaluation of a Hot-Humid Climate Community  

SciTech Connect (OSTI)

Project Home Again is a development in New Orleans, LA created to provide new homes to victims of Hurricane Katrina. Building Science Corporation acted as a consultant for the project, advocating design strategies for durability, flood resistance, occupant comfort, and low energy use while maintaining cost effectiveness. These techniques include the use of high density spray foam insulation, LoE3 glazing, and supplemental dehumidification to maintain comfortable humidity levels without unnecessary cooling.

Osser, R.; Kerrigan, P.

2012-02-01T23:59:59.000Z

136

alternating temperature preculture: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

A; Moi, L 2013-01-01 3 Warm Humid Climate: Methodology to Study Air Temperature Distribution: Mobile Phones Base Stations as Viable Alternative for Fixed Points Texas A&M...

137

The design, construction, and instrumentation of a chamber to study heat, mass, and momentum transfer from humid air to metal under conditions of frosting and free convection  

E-Print Network [OSTI]

THE DESIGN? CONSTRUCTION? AND INSTRUMENTATION OF A CEAMSER TO STUDY HEAT, MASS? AND MOSNTUM TRANSFER FROM HUMID AIR TO METAL UNDER CONDITIONS OF FROSTING AND FREE CONVECTION A Thesis By James P. Hutchison Submitted to the Graduate School... temperatures a cryogenic pump wss necessary. The sire of the pump was computed on the basis of maintaining a one degree Fahrenheit drop of the coolant temperature through the supply systms. The greatest heat load on the supply system being 3718 BTU per hour...

Hutchison, James P

1961-01-01T23:59:59.000Z

138

Optimize the Supply Air Temperature Reset Schedule for a Single-Duct VAV System  

E-Print Network [OSTI]

air temperature. However, resetting the supply air temperature not only impacts the cooling and heating energy consumption, but also the fan power consumption. If reset improperly, it may cause indoor air humidity problems or result in a fan power...

Wei, G.; Claridge, D. E.; Liu, M.

2000-01-01T23:59:59.000Z

139

Creating a Global Humidity DatasetCreating a Global Humidity Dataset Progress with the Marine ComponentProgress with the Marine Component  

E-Print Network [OSTI]

Creating a Global Humidity DatasetCreating a Global Humidity Dataset ­­ Progress with the Marine PROJECT SUMMARY CLIMATOLOGIES Create a global gridded monthly mean dataset of surface vapour pressure, Exeter, UK ­ CASE sponsors ICOADS, NCDC ­ for providing the marine dataset Philip Brohan, Hadley Centre

Feigon, Brooke

140

METEOROLOGY OF SO CLOUD REGIMES WORKSHOP ON SOUTHERN OCEAN CLOUDS & AND  

E-Print Network [OSTI]

regimes Regime meteorology Vertical pressure velocity Potential temperature Relative humidity Wind speed regimes Regime meteorology Vertical pressure velocity Potential temperature Relative humidity Wind speed Regime meteorology Vertical pressure velocity Potential temperature Relative humidity Wind speed

Jakob, Christian

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

BC TIPS - Hot-Humid Climate: New Orleans  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd: Scope ChangeL-01-06Hot-Humid Climate: New Orleans Building

142

Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate, Cocoa, Florida (Fact Sheet)  

SciTech Connect (OSTI)

Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season. ?

Not Available

2014-04-01T23:59:59.000Z

143

A study of winter precipitation areas in relation to several indicators of vertical motion  

E-Print Network [OSTI]

is moving over sloping terrain obtains an induced vertical component of velocity. The magnitude of t' he vertical com- ponent is directly related to the wind speed near the ground and to the angle of inclination of the slope in the direction of flow...) Relative Humidity: Values at 25-mb intervals were obtained by interpolation of data given at the contact points. A 107. rms error is likely in the data. The error would appear also in dew- point temperatures which were provided on the tape. 5) Wind...

Fuelberg, Henry Ernest

2012-06-07T23:59:59.000Z

144

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate  

SciTech Connect (OSTI)

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate t

Munk, Jeffrey D [ORNL; Gehl, Anthony C [ORNL; Jackson, Roderick K [ORNL

2012-04-01T23:59:59.000Z

145

ARM Energy Balance Bowen Ratio (EBBR) station: surf. heat flux and related data, 30-min  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

The Energy Balance Bowen Ratio (EBBR) system produces 30-min estimates of the vertical fluxes of sensible and latent heat at the local surface. Flux estimates are calculated from observations of net radiation, soil surface heat flux, and the vertical gradients of temperature and relative humidity. Meteorological data collected by the EBBR are used to calculate bulk aerodynamic fluxes, which are used in the Bulk Aerodynamic Technique (BA) EBBR value-added product (VAP) to replace sunrise and sunset spikes in the flux data. A unique aspect of the system is the automatic exchange mechanism (AEM), which helps to reduce errors from instrument offset drift.

Cook, David

146

Surface Temperature and Surface-Layer Turbulence in a Convective Boundary Layer  

E-Print Network [OSTI]

The vertical gradient of horizontal wind-speed was estimateda larger vertical gradient of horizontal wind-speed in thewind speed, direction, temperature, humidity up to 20 km with a vertical

Garai, Anirban; Pardyjak, Eric; Steeneveld, Gert-Jan; Kleissl, Jan

2013-01-01T23:59:59.000Z

147

Fast Response and High Sensitivity ZnO/glass Surface Acoustic Wave Humidity Sensors Using Graphene Oxide Sensing Layer  

E-Print Network [OSTI]

We report ZnO/glass surface acoustic wave (SAW) humidity sensors with high sensitivity and fast response using graphene oxide sensing layer. The frequency shift of the sensors is exponentially correlated to the humidity change, induced mainly...

Xuan, Weipeng; He, Mei; Meng, Nan; He, Xingli; Wang, Wenbo; Chen, Jinkai; Shi, Tianjin; Hasan, Tawfique; Xu, Zhen; Xu, Yang; Luo, J. K.

2014-11-26T23:59:59.000Z

148

The Effect of Humidity on the Reliability of a Surface Micromachined Microengine  

SciTech Connect (OSTI)

Humidity is shown to be a strong factor in the wear of rubbing surfaces in polysilicon micromachines. We demonstrate that very low humidity can lead to very high wear without a significant change in reliability. We show that the volume of wear debris generated is a function of the humidity in an air environment. As the humidity decreases, the wear debris generated increases. For the higher humidity levels, the formation of surface hydroxides may act as a lubricant. The dominant failure mechanism has been identified as wear. The wear debris has been identified as amorphous oxidized silicon. Large slivers (approximately 1 micron in length) of debris observed at the low humidity level were also amorphous oxidized silicon. Using transmission electron microscopy, we observed that the wear debris forms spherical and rod-like shapes. We compared two surface treatment processes: a fluorinated si- lane chain, (FITl) and supercritical C02 dried (SCC02). The microengines using the SCC02 process were found to be less reliable than those released with the FIX process under two humidity levels.

Dugger, M.T.; Eaton, W.P.; Irwin, L.W.; Miller, S.L.; Miller, W.M.; Smith, N.F.; Tanner, D.M.; Walraven, J.A.

1999-02-02T23:59:59.000Z

149

Photooxidation of Alpha-Pinene at High Relative Humidity in the Presence of  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 - September 2006 TheStevenAdministrationPhotometric

150

Posters A Comparison of Model-Simulated Relative Humidity with Satellite-Derived Cloudiness  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 - September 2006PhotovoltaicSeptember 22, 2014SocietyJ. Dudhia51 Posters A

151

SILICON CARBIDE MEMBRANE RELATIVE HUMIDITY SENSOR WITH ALUMINIUM E.J. Connolly, 2  

E-Print Network [OSTI]

, generally with a porous material between the electrodes which absorbs water from the air, thereby changing with, for example on-chip signal electronics, data storage and processing etc. Membrane or thin film that the thin back electrode, even though it is metallic, offers enough resistivity to act a Joule heater

Technische Universiteit Delft

152

Enthalpy Wheels Come of Age: Applying Energy Recovery Ventilation to Hospitality Venues in Hot, Humid Climate  

E-Print Network [OSTI]

ventilation to hospitality venues in hot, humid climates need not be complex. This paper proposes guidelines that can facilitate application of the technology by specifiers or other construction professionals. These guidelines address evaluation of typical...

Wellford, B. W.

2000-01-01T23:59:59.000Z

153

Applications of Commercial Heat Pump Water Heaters in Hot, Humid Climates  

E-Print Network [OSTI]

Heat pump water heaters can provide high-efficiency water heating and supplemental space cooling and dehumidification in commercial buildings throughout the United States. They are particularly attractive in hot, humid areas where cooling loads...

Johnson, K. F.; Shedd, A. C.

154

A passive cooling design for multifamily residences [sic] in hot, humid climates  

E-Print Network [OSTI]

People living in hot, humid climates suffer either from extremely uncomfortable weather conditions or from the great cost of air-conditioning systems for maintaining comfort. Most of the available passive cooling techniques ...

Tang, Joseph C

1983-01-01T23:59:59.000Z

155

Technical and Economic Analysis of Solar Cooling Systems in a Hot and Humid Climate  

E-Print Network [OSTI]

The aim of this paper is to promote efficient and cost effective implementation of advanced solar cooling systems and techniques for the hot and humid climates cities in the United States. After an introduction of basic principles, the development...

Moaveni, H.

156

Better Unitary Equipment Air-Handlers for Efficiency and Humidity Control  

E-Print Network [OSTI]

procedure gives too little credit for advanced air handlers that reduce air conditioning load and facilitate adaptive humidity control through automatic fan speed adjustment. DC permanent magnet variable speed motors have much lower market share than less...

Sachs, H. M.

2002-01-01T23:59:59.000Z

157

Climate regulation of humid tropical hydrology BHS 10th National Hydrology Symposium, Exeter, 2008  

E-Print Network [OSTI]

might influence tropical water resources. Introduction The humid tropics can be defined as the global, Bangladesh, and most of South-east Asia (Fosberg et al., 1961). Its climate contains distinctive dynamics

Chappell, Nick A

158

Facile fabrication of three-dimensional mesoporous Si/SiC composites via one-step magnesiothermic reduction at relative low temperature  

SciTech Connect (OSTI)

Graphical abstract: - Highlights: • The Si/SiC composites were synthesized by one-step magnesiothermic reduction. • The mesoporous composites have a high specific surface area (655.7 m{sup 2} g{sup ?1}). • The composites exhibited a strong photoluminescence and better biocompatibility. • The mechanisms of formation and photoluminescence of sample were discussed. - Abstract: By converting modified silica aerogels to the corresponding silicon/silicon carbide (Si/SiC) without losing its nanostructure, three-dimensional mesoporous (3DM) Si/SiC composites are successfully synthesized via one-step magnesothermic reduction at relative low temperature (650 °C). The phase composition and microstructure of the resulting samples are measured by X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDX), Raman spectra, scanning electron microscopy (SEM) and transmission electron microscopy (TEM). N{sub 2}-sorption isotherms results show that the products have high Brunauer–Emmett–Teller (BET) specific surface areas (up to 656 m{sup 2} g{sup ?1}) and narrow pore-size distributions (1.5–30 nm). The composites exhibit a strong photoluminescence (PL) in blue-green light region (peak centered at 533 nm). We have set out work on the biocompatibility and enhancing PL of samples. As a result of excellent performances of the composites, it can be expected to have significant application in optoelectronics, biosensors, biological tracer and so on.

Jiang, Zhihang; Ma, Yongjun [State Key Laboratory Cultivation Base for Nonmetal Composites and Functional Materials, Southwest University of Science and Technology, Mianyang 621010 (China); Zhou, Yong [Eco-materials and Renewable Energy Research Center (ERERC), School of Physics, National Lab of Solid State Microstructure, ERERC, Nanjing University, Nanjing 210093 (China); Hu, Shanglian [School of Life Science and Engineering, Southwest University of Science and Technology, Mianyang 621010 (China); Han, Chaojiang [State Key Laboratory Cultivation Base for Nonmetal Composites and Functional Materials, Southwest University of Science and Technology, Mianyang 621010 (China); Pei, Chonghua, E-mail: peichonghua@swust.edu.cn [State Key Laboratory Cultivation Base for Nonmetal Composites and Functional Materials, Southwest University of Science and Technology, Mianyang 621010 (China)

2013-10-15T23:59:59.000Z

159

Role of Wind in Vernacular Architecture of Hot and Humid Region of Iran  

E-Print Network [OSTI]

the total framework which underlies architecture. Vernacular architecture in hot and humid regions of Iran has strong bonds with local climate. Shenasil, Taremi and Wind towers are the features that have developed according to climatic considerations... of different climatic elements on the vernacular architecture with a focus on humidity and air currents. Then, natural ventilation and the architectural elements involving it will be discussed. Finally, the wind towers of the region...

Najafabadi, R. A.; Daneshvar, K.; Pakseresht, K.; Pooryousefzadeh, S.

2006-01-01T23:59:59.000Z

160

Expert Meeting: Recommended Approaches to Humidity Control in High Performance Homes  

SciTech Connect (OSTI)

The topic of this Building America expert meeting was 'Recommended Approaches to Humidity Control in High Performance Homes,' which was held on October 16, 2012, in Westford, MA, and brought together experts in the field of residential humidity control to address modeling issues for dehumidification. The presentations and discussions centered on computer simulation and field experience with these systems, with the goal of developing foundational information to support the development of a Building America Measure Guideline on this topic.

Rudd, A.

2013-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Surface reactivity and oxygen migration in amorphous indium-gallium-zinc oxide films annealed in humid atmosphere  

SciTech Connect (OSTI)

An isotope tracer study, i.e., {sup 18}O/{sup 16}O exchange using {sup 18}O{sub 2} and H{sub 2}{sup 18}O, was performed to determine how post-deposition annealing (PDA) affected surface reactivity and oxygen diffusivity of amorphous indium–gallium–zinc oxide (a-IGZO) films. The oxygen tracer diffusivity was very high in the bulk even at low temperatures, e.g., 200?°C, regardless of PDA and exchange conditions. In contrast, the isotope exchange rate, dominated by surface reactivity, was much lower for {sup 18}O{sub 2} than for H{sub 2}{sup 18}O. PDA in a humid atmosphere at 400?°C further suppressed the reactivity of O{sub 2} at the a-IGZO film surface, which is attributable to –OH-terminated surface formation.

Watanabe, Ken, E-mail: Watanabe.Ken@nims.go.jp [International Center for Young Scientists (ICYS-MANA), National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba 305-0044 (Japan)] [International Center for Young Scientists (ICYS-MANA), National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba 305-0044 (Japan); Lee, Dong-Hee [Optical and Electronic Materials Unit, NIMS, 1-1 Namiki, Tsukuba 305-0044 (Japan) [Optical and Electronic Materials Unit, NIMS, 1-1 Namiki, Tsukuba 305-0044 (Japan); Materials and Structures Laboratory (MSL), Tokyo Institute of Technology, Mailbox R3-4, 4259 Nagatsuta, Midori-ku, Yokohama 226-0026 (Japan); Sakaguchi, Isao; Haneda, Hajime [Optical and Electronic Materials Unit, NIMS, 1-1 Namiki, Tsukuba 305-0044 (Japan)] [Optical and Electronic Materials Unit, NIMS, 1-1 Namiki, Tsukuba 305-0044 (Japan); Nomura, Kenji [Frontier Research Center, Tokyo Institute of Technology, Mailbox S2-13, 4259 Nagatsuta, Midori-ku, Yokohama 226-0026 (Japan)] [Frontier Research Center, Tokyo Institute of Technology, Mailbox S2-13, 4259 Nagatsuta, Midori-ku, Yokohama 226-0026 (Japan); Kamiya, Toshio [Materials and Structures Laboratory (MSL), Tokyo Institute of Technology, Mailbox R3-4, 4259 Nagatsuta, Midori-ku, Yokohama 226-0026 (Japan) [Materials and Structures Laboratory (MSL), Tokyo Institute of Technology, Mailbox R3-4, 4259 Nagatsuta, Midori-ku, Yokohama 226-0026 (Japan); Materials Research Center for Element Strategy (MCES), Mailbox S2-13, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama 226-0026 (Japan); Hosono, Hideo [Materials and Structures Laboratory (MSL), Tokyo Institute of Technology, Mailbox R3-4, 4259 Nagatsuta, Midori-ku, Yokohama 226-0026 (Japan) [Materials and Structures Laboratory (MSL), Tokyo Institute of Technology, Mailbox R3-4, 4259 Nagatsuta, Midori-ku, Yokohama 226-0026 (Japan); Frontier Research Center, Tokyo Institute of Technology, Mailbox S2-13, 4259 Nagatsuta, Midori-ku, Yokohama 226-0026 (Japan); Materials Research Center for Element Strategy (MCES), Mailbox S2-13, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama 226-0026 (Japan); Ohashi, Naoki, E-mail: Ohashi.Naoki@nims.go.jp [Optical and Electronic Materials Unit, NIMS, 1-1 Namiki, Tsukuba 305-0044 (Japan) [Optical and Electronic Materials Unit, NIMS, 1-1 Namiki, Tsukuba 305-0044 (Japan); Materials Research Center for Element Strategy (MCES), Mailbox S2-13, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama 226-0026 (Japan)

2013-11-11T23:59:59.000Z

162

Plant and microbial controls on nitrogen retention and loss in a Humid Tropical Forest  

SciTech Connect (OSTI)

Humid tropical forests are generally characterized by the lack of nitrogen (N) limitation to net primary productivity, yet paradoxically have high potential for N loss. We conducted an intensive field experiment with {sup 15}NH{sub 4} and {sup 15}NO{sub 3} additions to highly weathered tropical forest soils to determine the relative importance of N retention and loss mechanisms. Over half of all the NH{sub 4}{sup +} produced from gross mineralization was rapidly converted to NO{sub 3}{sup -} during the process of gross nitrification. During the first 24 h plant roots took up 28 % of the N mineralized, dominantly as NH{sub 4}{sup +}, and were a greater sink for N than soil microbial biomass. Soil microbes were not a significant sink for added {sup 15}NH{sub 4}{sup +} or {sup 15}NO{sub 3}{sup -} during the first 24 hr, and only for {sup 15}NH{sub 4}{sup +} after 7 d. Patterns of microbial community composition, as determined by Terminal Restriction Fragment Length Polymorphism analysis, were weakly, but significantly correlated with nitrification and denitrification to N{sub 2}O. Rates of dissimilatory NO{sub 3}{sup -} reduction to NH{sub 4}{sup +} (DNRA) were high in this forest, accounting for up to 25 % of gross mineralization and 35 % of gross nitrification. DNRA was a major sink for NO{sub 3}{sup -} which may have contributed to the lower rates of N{sub 2}O and leaching losses. Despite considerable N conservation via DNRA and plant NH{sub 4}{sup +} uptake, the fate of approximately 45% of the NO{sub 3}{sup -} produced and 22% of the NH{sub 4}{sup +} produced were not measured in our fluxes, suggesting that other important pathways for N retention and loss (e.g., denitrification to N{sub 2}) are important in this system. The high proportion of mineralized N that was rapidly nitrified and the fates of that NO{sub 3}{sup -} highlight the key role of gross nitrification as a proximate control on N retention and loss in humid tropical forest soils. Furthermore, our results demonstrate the importance of the coupling between DNRA and plant uptake of NH{sub 4}{sup +} as a potential N conserving mechanism within tropical forests.

Templer, P.; Silver, W.; Pett-Ridge, J.; DeAngelis, K.M.; Firestone, M.K.

2009-09-15T23:59:59.000Z

163

The Effects of Test Temperature, Temper, and Alloyed Copper on the Hydrogen-Controlled Crack Growth Rate of an Al-Zn-Mg-(Cu) Alloy  

SciTech Connect (OSTI)

The hydrogen embrittlement controlled stage II crack growth rate of AA 7050 (6.09 wt.% Zn, 2.14 wt% Mg, 2.19 wt.% Cu) was investigated as a function of temper and alloyed copper level in a humid air environment at various temperatures. Three tempers representing the underaged, peak aged, and overaged conditions were tested in 90% relative humidity (RH) air at temperatures between 25 and 90 C. At all test temperatures, an increased degree of aging (from underaged to overaged) produced slower stage II crack growth rates. The stage II crack growth rate of each alloy and temper displayed Arrhenius-type temperature dependence with activation energies between 58 and 99 kJ/mol. For both the normal copper and low copper alloys, the fracture path was predominantly intergranular at all test temperatures (25-90 C) in each temper investigated. Comparison of the stage II crack growth rates for normal (2.19 wt.%) and low (0.06 wt.%) copper alloys in the peak aged and overaged tempers showed the beneficial effect of copper additions on stage II crack growth rate in humid air. In the 2.19 wt.% copper alloy, the significant decrease ({approx} 10 times at 25 C) in stage II crack growth rate upon overaging is attributed to an increase in the apparent activation energy for crack growth. IN the 0.06 wt.% copper alloy, overaging did not increase the activation energy for crack growth but did lower the pre-exponential factor, {nu}{sub 0}, resulting in a modest ({approx} 2.5 times at 25 C) decrease in crack growth rate. These results indicate that alloyed copper and thermal aging affect the kinetic factors that govern stage II crack growth rate. Overaged, copper bearing alloys are not intrinsically immune to hydrogen environment assisted cracking but are more resistant due to an increased apparent activation energy for stage II crack growth.

G.A. Young, Jr.; J.R. Scully

2000-09-17T23:59:59.000Z

164

Innovative HVAC Cycles for Severe Part Load Conditions in the Humid Climate  

E-Print Network [OSTI]

Final Report for Pacific Division of the Naval 1. OESICN DAY 2. TRWBLE RC WITH 80/78 3. TRaBLE PLC WIM 75/69 4. TlEOUBLE Pk WITH 70/65 m mL rnITIONS 1. OESICN DAY 2. TROUEU PLC WITH 80/78 3. TRNBLE PLC WITH 75/69 4. TRCUBCE RC WITH 70/65 CMJ..., Arlington, Texas, 1986. 3. Todd, T., Pate, M., "Passive Humidity Control: A Comparison of Air Conditioning Capaci- ty Control Methods for the Humid Climate ,I1 ASHRAE Far East Conference, Singapore, September, 1987. 4. Meckler, Gershon, "Energy...

Pate, M. E.; Todd, T. R.

1987-01-01T23:59:59.000Z

165

Small Residence Multizone Modeling with Partial Conditioning for Energy Effieiency in Hot and Humid Climates  

E-Print Network [OSTI]

The purpose of this study is to reduce the energy cost of the low-income households in the hot and humid climates of the U.S. and thereby to help them afford comfortable homes. In this perspective, a new HVAC energy saving strategy, i.e. “partial...

Andolsun, Simge

2013-07-30T23:59:59.000Z

166

Energy Wheel Performance and Optimization Opportunities for SDVAV AHU's In a Hot & Humid Climate  

E-Print Network [OSTI]

The HVAC system accounts for 30 to 50 percent of a typical building's energy consumption; in hot & humid climates it is closer to the upper end of that range. Implementing effective energy saving measures for the building HVAC system can reduce...

Zhao, J.; Wang, L.; Watt, J.

2012-01-01T23:59:59.000Z

167

Bio-Char Soil Management on Highly Weathered Soils in the Humid Tropics  

E-Print Network [OSTI]

therefore have to be applied each year to sustain soil productivity. Management of black carbon (C36 Bio-Char Soil Management on Highly Weathered Soils in the Humid Tropics Johannes Lehmann1), ColombiaQ1 CONTENTS 36.1 Bio-Char Management and Soil Nutrient Availability

Lehmann, Johannes

168

THE EFFECTS OF DIFFERENT HUMIDITIES ON THE HATCHING OF THE EGGS OF HONEYBEES  

E-Print Network [OSTI]

. Provision of water inside the hive remedies this condition, and normal broodrearing is resumed. (DOULL and of the remainder, only 2.9 % produced normal larvae. No eggs hatched at humidities below 50 % R.H. Abnormal plane, releasing the hat- ching fluid which dissolves the chorion. If free water is present in the cell

Paris-Sud XI, Université de

169

Safety First Safety Last Safety Always Summer in Minnesota means high humidity and sunny, hot  

E-Print Network [OSTI]

Safety First Safety Last Safety Always Summer in Minnesota means high humidity and sunny, hot days the victim liquids to drink. Treat for shock until professional medical help arrives. Heat Stress Safety Tip the information provided on the reverse side of this safety tip sheet. Please refrain from reading the information

Minnesota, University of

170

Matrix penetration in the bulk:In uence of humidity: Morphological analysis of wood welding  

E-Print Network [OSTI]

Matrix penetration in the bulk:In uence of humidity: Morphological analysis of wood welding.pichelin@b .ch Context: Wood can be welded using linear vibration welding tech- niques similar to the ones in plastic and metal industry[1] . Wood welding allows bonding strength similar to glued joints. However, due

Dalang, Robert C.

171

Air Conditioner Efficiency Under Hot Dry and Hot Humid Conditions - The Utility Perspective  

E-Print Network [OSTI]

Air Conditioner Efficiency under Hot Dry and Hot Humid Conditions - The Utility Perspective Ammi Amarnath Technical Leader, Energy Efficiency & Demand Response Program Electric Power Research Institute 3420 Hillview Avenue Palo Alto, CA... are summarized below. Recommendations ? Establish a utility and energy efficiency agency coordinating council for regional standards; ? Identify regional centers to provide the institutional support; ? Develop recommended best practices for regionally based...

Amarnath, A.

172

Victoria & Albert Museum- Medieval & Renaissance Galleries: A Passive Approach to Humidity Control  

E-Print Network [OSTI]

Victoria & Albert Museum, London Medieval & Renaissance Galleries: A Passive Approach to Humidity Control Andrew Lerpiniere Steve Walker Michael Bingham Associate Director Associate Director Engineer Arup London, UK ABSTRACT The new... usage, running costs and carbon dioxide emissions of the galleries. REFERENCES 1. Victoria & Albert Museum; Medieval & Renaissance; Environmental Analysis of Perimeter galleries; November 2006; Andrew Lerpiniere, Michael Bingham, Steve...

Lerpiniere, A.; Bingham, M.; Walker, S.

2010-01-01T23:59:59.000Z

173

V&A Medieval & Renaissance Galleries: A Passive Approach to Humidity Control  

E-Print Network [OSTI]

Victoria & Albert Museum, London Medieval & Renaissance Galleries: A Passive Approach to Humidity Control Andrew Lerpiniere Steve Walker Michael Bingham Associate Director Associate Director Engineer Arup London, UK ABSTRACT The new... of the galleries. REFERENCES 1. Victoria & Albert Museum; Medieval & Renaissance; Environmental Analysis of Perimeter galleries; November 2006; Andrew Lerpiniere, Michael Bingham, Steve Walker ? Arup 2. Museum Environmental Conditions in an Era...

Lerpiniere, A.

2011-01-01T23:59:59.000Z

174

Dry Bias in Vaisala RS90 Radiosonde Humidity Profiles over Antarctica PENNY M. ROWE  

E-Print Network [OSTI]

measurements made by radio- sondes. Some radiosonde humidity sensors experience a dry bias caused by solar were launched in clear skies at solar zenith angles (SZAs) near 83° and 62°. As part of this field) for SZAs near 83°; they are 20% 6% and 24% 5% for SZAs near 62°. Assuming solar heating is minimal at SZAs

Walden, Von P.

175

QUALIT DES ENSILAGES DE MAS GRAIN HUMIDE PRSERVS PAR L'ACIDE PROPIONIQUE  

E-Print Network [OSTI]

product) and acetic (0,1-0,3 per cent) acids are produced by carbohydrate fermentation. The silage p maïs grain humide, la fermentation des glucides entraîne une pro- duction notable d'acides lactique (0 degradative change is practically inhi- bited after 3 to 8 months : in our assays, lactic and acetic acids

Paris-Sud XI, Université de

176

The fatigue of high-strength fused silica optical fibers in low humidity q  

E-Print Network [OSTI]

the effect of humidity on the kinetics of subcritical crack growth in high strength optical fibers that the rate of subcritical crack growth is given by dc dt ¼ A exp n KI KIC ; ð1� where A and n are fatigue by assuming a simple chemical kinetics model for fatigue in which the reaction rate between water and silica

Matthewson, M. John

177

Relation between hydrogen isotopic ratios of bone collagen and rain  

SciTech Connect (OSTI)

The hydrogen isotopic value ([delta]D) of deer bone collagen is related to both [delta]D of rain during the growing season and growing season relative humidity (RH). With correction for the effects of RH, bone [delta]D is related to growing season rain [delta]D in a simple manner with a slope of 1.0. This indicates that, with RH correction, there are no additional sources of bias in the [delta]D of bone due to unaccounted for biologic or climatic effects. Due to a low sensitivity of bone [delta]D to RH effects, both yearly and growing season rain [delta]D can be estimated with considerable accuracy (R = 0.97 and R = 0.96) from bone collagen [delta]D and [delta][sup 15]N. Here, [delta][sup 15]N is used to correct bone [delta]D for the effects of RH. From these estimates of rain [delta]D, it may then be possible to evaluate temperature since the [delta]D of rain primarily reflects local temperature. Therefore, the measurement of bone collagen [delta]D has good potential for evaluating paleoclimates.

Cormie, A.B.; Schwarcz, H.P. (McMaster Univ., Hamilton, Ontario (Canada)); Gray, J. (Univ. of Alberta, Edmonton (Canada))

1994-01-01T23:59:59.000Z

178

A KNOWLEDGE DISCOVERY STRATEGY FOR RELATING SEA SURFACE TEMPERATURES TO FREQUENCIES OF TROPICAL STORMS AND GENERATING PREDICTIONS OF HURRICANES UNDER 21ST-CENTURY GLOBAL WARMING SCENARIOS  

SciTech Connect (OSTI)

The connections among greenhouse-gas emissions scenarios, global warming, and frequencies of hurricanes or tropical cyclones are among the least understood in climate science but among the most fiercely debated in the context of adaptation decisions or mitigation policies. Here we show that a knowledge discovery strategy, which leverages observations and climate model simulations, offers the promise of developing credible projections of tropical cyclones based on sea surface temperatures (SST) in a warming environment. While this study motivates the development of new methodologies in statistics and data mining, the ability to solve challenging climate science problems with innovative combinations of traditional and state-of-the-art methods is demonstrated. Here we develop new insights, albeit in a proof-of-concept sense, on the relationship between sea surface temperatures and hurricane frequencies, and generate the most likely projections with uncertainty bounds for storm counts in the 21st-century warming environment based in turn on the Intergovernmental Panel on Climate Change Special Report on Emissions Scenarios. Our preliminary insights point to the benefits that can be achieved for climate science and impacts analysis, as well as adaptation and mitigation policies, by a solution strategy that remains tailored to the climate domain and complements physics-based climate model simulations with a combination of existing and new computational and data science approaches.

Race, Caitlin [University of Minnesota; Steinbach, Michael [University of Minnesota; Ganguly, Auroop R [ORNL; Semazzi, Fred [North Carolina State University; Kumar, Vipin [University of Minnesota

2010-01-01T23:59:59.000Z

179

Energy Conservation Experiences with HVAC Systems in the High Humidity Climate, A Case History  

E-Print Network [OSTI]

ENERGY CONSERVATION EXPERIENCES VITH HVAC SYSTEMS IN THE HIGH HUMIDITY CLIMATE. A CASE HISTORY Tom R. Todd Principa 1 Engineering Sciences, Inc. Memphis, Tennessee 38112 The purpose of this paper is to discuss sev- era 1 commonly encountered.... Condensation during normal sys tern opere- tion. It was frequently found that moisture in the room air would condense on cold surfaces around supply air diffusers during normal opera- tion of the system. Direct evidence of this was simply the presence...

Todd, T. R.

1985-01-01T23:59:59.000Z

180

Development and Analysis of a Sustainable Low Energy House in a Hot and Humid Climate  

E-Print Network [OSTI]

cooling. In cold-climate countries, electricity is often used for space heating as well. Natural gas is mainly Energy Used in Building Demolition Demolition Removal Energy Used in Building Operation Space Cooling Lighting Equipment Water... Lifetime Building Energy Consumption Figure 1: Lifetime Building Energy Consumption Components for a Typical Residence in Thailand. used for only cooking for hot and humid climates such as Thailand. In cold climates, gas is also used for space...

Chulsukon, P.; Haberl, J. S.; Degelman, L. O.; Sylvester, K. E.

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Integrated Hygrothermal Performance of Building Envelopes and Systems in Hot and Humid Climates  

E-Print Network [OSTI]

Technology Center VTT Building Technology, Oak Ridge National Laboratory, Oak Ridge National Laboratory, Espoo, Finland Building Technology Center, Oak Ridge, Tennessee, US Oak Ridge, Tennessee, US ABSTRACT In hot and humid climates the interior... retarders reduce risk of moisture damage, Proceedings of the 4th Symposium, Building Physics in the Nordic Countries, Espoo, Finland, Sept. 9-10, pp.447-454. Karagiozis, A. and Hadjisophocleous G. "Wind- Driven Rain on High-Rise Buildings", Thermal...

Karagiozis, A. N.; Desjarlais, A.; Salonvaara, M.

2000-01-01T23:59:59.000Z

182

Direct-Expansion Air-Conditioning System Performance in Low Humidity Applications: A Case Study  

E-Print Network [OSTI]

DIRECT-EXPANSION AIR-CONDITIONING SYSTEM PERFORMANCE IN LOW HUMIDITY APPLICATIONS: A CASE STUDY MUKESH K. KHATTAR, P.E. DENNIS KEEBAUGH, P.E. Senior Systems Engineer Senior Research Engineer Florida Solar Energy Center Shenandoah Solar Center... warehouse. The flat gravel roof is exposed to sun. The 16' ceiling is insulated with two inch spray foam. Entrance to the warehouse is through sealed and insulated doors located on the west partition wall. The air -conditioning sys tem on this leased...

Khattar, M. K.; Keebaugh, D.

1987-01-01T23:59:59.000Z

183

Energy Master Plans for Sustainable, High Performance HVAC and Associated Systems for Hot and Humid Climates  

E-Print Network [OSTI]

ENERGY MASTER PLANS for SUSTAINABLE, HIGH PERFORMANCE HVAC & ASSOCIATED SYSTEMS for HOT AND HUMID CLIMATES Grahame E. Maisey, P.E. Beverly Milestone Chief Engineer President GEMCO Energy Master Planners GEMCO Energy... net zero energy, high performance productivity and long-life systems for minimal material use. This is achieved by a number of small, easy steps and at a rate and schedule determined by the owner. Projects will eventually reduce HVAC...

Maisey, G. E.; Milestone, B.

2004-01-01T23:59:59.000Z

184

The effect of humidity on the collection efficiency for oxygenated compounds adsorbed on activated charcoal  

E-Print Network [OSTI]

and analyzed by gas chromatography. The National Institute for Occupational Safety and Health (NIOSH) has adopted this technique for more than one hundred individual chemicals. ~ One problem with using any adsorbent as a collection media is its ability...THE EPPECT OP HUMIDITY ON THE COLIECTION EFFICIENCY POR OXYGENATED COMPOUNDS ADSORBED ON ACTIVATED CHARCOAL A Thesis by ROBERT BRUCE WALTON Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment...

Walton, Robert Bruce

1990-01-01T23:59:59.000Z

185

Appropriate Conservation Measures for Single-Family Buildings in Hot, Humid Climates  

E-Print Network [OSTI]

, and skin wetness, and they should be investigated. REFERENCES 1. "Residential Conservation Service Model Audit Manual," Oak Ridge National Laboratory, ORNL/CON-103, October 1983. 2. "WE-2 Reference Manual, Version 2. LA," LBL-8706, Rev. 2, May 1981..., Thermal Comfort, Krieger Publishing Co., Malabar, Florida, 1982. 9. H. A. McLain, J. M. MacDonald, D. Goldenberg, "Appropriate Conservation Measures for Single-Family Buildings in Hot Humid Climates,'' ORNL/CON report, to be issued. 10. R. Messenger...

McLain, H. A.; MacDonald, J. M.; Goldenberg, D.

1985-01-01T23:59:59.000Z

186

An Analysis of Maximum Residential Energy Efficiency in Hot and Humid Climates  

E-Print Network [OSTI]

the high efficiency instantaneous water heater with electronic ignition. The largest equipment energy savings (20%) was achieved from the horizontal-axis clothes washer. Compact fluorescent lamps (CFLs) saved 75% lighting energy use. Among all...AN ANALYSIS OF MAXIMUM RESIDENTIAL ENERGY EFFICIENCY IN HOT AND HUMID CLIMATES Mini Malhotra Graduate Research Assistant Jeff Haberl, Ph.D., P.E. Professor/Associate Director Energy Systems Laboratory, Texas A&M University College...

Malhotra, M.; Haberl, J. S.

2006-01-01T23:59:59.000Z

187

An Analysis of Building Envelope Upgrades for Residential Energy Efficiency in Hot and Humid Climates  

E-Print Network [OSTI]

type, and HV AC and DHW system type were determined from the housing survey data by the National Association of Home Builders (NAHB 2003) and the U.S. Census Bureau (USCB 2002). The characteristics of the building envelope, efficiency of HV AC... of Improved Fenestration for Code-Compliant Residential Buildings in Hot and Humid Climates. M.S. Thesis. College Station, TX: Texas A&M University. NAHB. 2003. The Builders Practices Survey Reports. National Association of Home Builders. Upper Marlboro...

Malhotra, M.; Haberl, J.

188

Effect of Soaking in Hot Saline Solution and Humid Atmosphere on the Passive Film Behavior of a Ni-Cr-Mo Alloy  

SciTech Connect (OSTI)

Alloy 22, a Ni-Cr-Mo alloy, is the candidate material for fabrication of canisters for disposal of high-level and spent nuclear fuel waste in the proposed Yucca Mountain repository in Nevada. This paper investigated the passive film behavior and corrosion properties on Alloy 22 as a function of soaking in hot, saline environments and in hot, humid atmospheres. Environmental parameters include potential, temperature, pH in chloride and multi-species solutions. Hot, humid exposures are planned for temperatures up to 300 C. Soaking times are planned to extend for up to 1000 hours. This work is part of a multi-investigator study to determine the durability of passive films and localized corrosion processes in metal exposed to moist particulate and deposits. Of particular interest are the long-term stability of the passive film and the effects of soaking in aqueous solutions or hot, humid atmospheres. A combination of electrochemical methods measure changes in passive film properties, and a combination of surface analysis techniques are used to characterize the film composition and structure. Electrochemical methods include Potentiodynamic Polarization tests for the general corrosion behavior; along with Electrochemical Impedance Spectroscopy (EIS) and Mott-Schottky (M-S) analysis for electronic properties of the passive films. Alterations in the chemical composition and structure of the passive film are characterized using X-ray Photoelectron Spectroscopy (XPS), Auger Electron Spectroscopy (AES) and Transmission Electron Microscopy (TEM). Results for freshly formed films are shown in figure 1. The EIS results show that the interfacial impedance increased with increasing potential to maximum within the passive range and then decreased as the potential was increased further. interfacial impedance was found to decrease with increasing temperature. Mott-Schottky analysis indicated that the oxide film which is n-type in the passive region changes to p-type in the transpassive region. Figure 2 shows the representative chemical soaking results at 90 C for up to 240 hours; the interfacial impedance increased with soaking time. Results from this work are combined with those from collaborative studies to correlate the passive film properties with the resistance to localized corrosion using multi-crevice assemblies and micro-corrosion cells. The passive film growth and dissolution are interpreted with reference to processes based on the point defect model.

P. Pharkya; J.H. Payer

2006-06-09T23:59:59.000Z

189

Development of Temperature and Humidity-Based Indicators for Diagnosing Problems in Low Tonnage, Split System Air Conditioners  

E-Print Network [OSTI]

of HVAC systems for building optimization, fault detection and diagnosis. October. Finland: Technical Research Center of Finland, Laboratory of Heating and Ventilation, B. 0. Box 206 (Lampomiehenkuja 3) 02150 ESPOO. Kaler. G. 1988. Expert system...

Watt, J. B.; O'Neal, D. L.; Haberl, J. S.

1998-01-01T23:59:59.000Z

190

Factors contributing to the degradation of poly(p-phenylene benzobisoxazole) (PBO) fibers under elevated temperature and humidity conditions  

E-Print Network [OSTI]

accelerated hydrolytic degradation tests that production procedures used to neutralize the acid present in the fibers have a beneficial effect on the hydrolytic performance of the fiber. The data collected in this study was then compared and contrasted...

O'Neil, Joseph M

2006-10-30T23:59:59.000Z

191

Experimental Study in Energy Performance of Temperature and Humidity Independent Control System with Multiple Split Air-Conditioning System  

E-Print Network [OSTI]

? 2? 22 ? 2? 26 ? 2? 27 ? 2? 28 ? ? ? ? ? ? ? ? [k W h/ ? ] (2) Measurements of equipment efficiency and power consumption 0 0.05 0.1 0.15 0.2 0.25 0.3 7? 6? 7? 10 ? 7? 11 ? 7? 12 ? 7? 20 ? 7? 23 ? 7? 24 ? 7? 25 ? 7? 26 ? 7? 27 ? 8? 15 ? 8? 16 ? 8?.../ 27 -0 ? ? ? ? ?k W ) 0 5 10 15 20 25 30 35 12 /3 -0 12 /4 -0 12 /5 -0 12 /6 -0 12 /7 -0 12 /1 0- 0 12 /1 1- 0 12 /1 2- 0 12 /1 3- 0 12 /1 4- 0 12 /1 7- 0 12 /1 8- 0 12 /1 9- 0 12 /2 0- 0 12 /2 1- 0 12 /2 5- 0 12 /2 6- 0 12 /2 7- 0 12 /2 8- 0 1/ 4- 0 1...

Kawano,M.

2014-01-01T23:59:59.000Z

192

The use of a distributed hydrologic model to predict dynamic landslide susceptibility for a humid basin in Puerto Rico  

E-Print Network [OSTI]

This thesis describes the use of a distributed hydrology model in conjunction with a Factor of Safety (FS) algorithm to predict dynamic landslide susceptibility for a humid basin in Puerto Rico. The Mameyes basin, located ...

Kamal, Sameer A. (Sameer Ahmed)

2009-01-01T23:59:59.000Z

193

Natural Ventilation Applications in Hot-humid Climate: A Preliminary Design for the College of Design at NTUST  

E-Print Network [OSTI]

In Taiwan’s humid environment, the application of natural ventilation is an essential passive strategy for high performance buildings. However, conventional architectural design tools are rarely capable of analyzing the unpredictable air currents...

Lin, M. T.; Wei, H. Y.; Lin, Y. J.; Wu, H. F.; Liu, P. H.

194

Roots of Mold Problems and Humidity Control Measures in Institutional Buildings with Pre-Existing Mold Condition  

E-Print Network [OSTI]

Management, and the TAMU Physical Plant, was dispatched to perform Continuous Commissioning on these commercial buildings in order to find viable solutions to the humidity problem. The CC group performed extensive field tests and analysis on building air...

Chen, H.; Deng, S.; Bruner, H.; Garcia, J.

2004-01-01T23:59:59.000Z

195

Simulation of Dehumidification Characteristics of High Efficiency Residential Central Air-Conditioners in Hot and Humid Climates  

E-Print Network [OSTI]

This study assesses the dehumidifying performance of the high efficiency residential central air conditioners (CAC) in hot/humid climates typified by that of Houston and Galveston. The performance study is based on such factors as: (i) weather (ii...

Katipamula, S.; O'Neal, D.; Somasundram, S.

1988-01-01T23:59:59.000Z

196

Low temperature cryoprobe  

DOE Patents [OSTI]

A portable, hand held probe usable within a small confine to produce a point source of nitrogen or helium at a relatively constant temperatures of 77 degrees Kelvin, is discussed. 3 figs.

Sungaila, Z.F.

1988-04-12T23:59:59.000Z

197

Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate  

SciTech Connect (OSTI)

This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA.Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

Kerrigan, P.; Norton, P.

2014-10-01T23:59:59.000Z

198

Pressure &Pressure & TemperatureTemperature  

E-Print Network [OSTI]

to measure atmospheric pressure, and thermometer toprobe to measure atmospheric pressure, and thermometer toprobe to measure atmospheric pressure, and thermometer toprobe to measure atmospheric pressure, and thermometer to measure air temperature.measure air temperature.measure air temperature.measure air temperature

California at Santa Cruz, University of

199

Underground reconnaissance and environmental monitoring related to geologic CO2 sequestration studies at the DUSEL Facility, Homestake Mine, South Dakota  

SciTech Connect (OSTI)

Underground field reconnaissance was carried out in the Deep Underground Science and Engineering Laboratory (DUSEL) to identify potential locations for the planned geologic carbon sequestration experimental facility known as DUSEL CO{sub 2}. In addition, instrumentation for continuous environmental monitoring of temperature, pressure, and relative humidity was installed at various locations within the Homestake mine. The motivation for this work is the need to locate and design the DUSEL CO{sub 2} facility currently being planned to host CO{sub 2} and water flow and reaction experiments in long column pressure vessels over large vertical length scales. Review of existing geologic data and reconnaissance underground revealed numerous potential locations for vertical experimental flow columns, with limitations of existing vertical boreholes arising from limited vertical extent, poor continuity between drifts, and small diameter. Results from environmental monitoring over 46 days reveal spatial and temporal variations related to ventilation, weather, and ongoing dewatering of the mine.

Dobson, Patrick F.; Salve, Rohit

2009-11-20T23:59:59.000Z

200

Energy Retrofit Field Study and Best Practices in a Hot-Humid Climate  

SciTech Connect (OSTI)

Energy efficiency improvement as a component of comprehensive renovation was investigated under U.S. Department of Energy (DOE) funding of the Building America Partnership for Improved Residential Construction (BA-PIRC). Researchers at the Florida Solar Energy Center (FSEC) worked with affordable housing partners renovating foreclosed homes built from the 1950's through the 2000's in the hot-humid climate (within the Southern census region), primarily in Florida. Researchers targeted a 30% improvement in whole-house energy efficiency along with the health and safety, durability, and comfort guidelines outlined in DOE's Builders Challenge Program (Version 1) Quality Criteria.

McIvaine, J.; Sutherland, K.; Martin, E.

2013-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Guides and Case Studies for Mixed-Humid Climates | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAX POLICIES7.pdfFuel Celland Contractors | Department ofMixed-Humid Climates Guides

202

Absorption and translocation of 2,4-D in beans as influenced by relative humidity and soil moisture  

E-Print Network [OSTI]

neoesaax'y for al30orpliion and trinsloca- tion of dorbio10es ln mesquite. Plant's in small irx lp:ted , -, lots within lar~~'e areas oprayed w1th hoxbicides showed no dis- adv' nlj" g~'e ovsx' un'L Ltered plants in basF 1 ortcp Lci]. 1 Con versely, a...

Leinweber, Charles Lee

1953-01-01T23:59:59.000Z

203

808 IEEE TRANSACTIONS ON PLASMA SCIENCE, VOL. 33, NO. 2, APRIL 2005 Effect of Relative Humidity on Electron Distribution  

E-Print Network [OSTI]

unipolar ion source for charging objects, such as particles or surfaces in electrostatic precipitators

Chen, Junhong

204

The flowering and growth response of peanut plants (Arachis hypogaea L. var. Starr) at two different levels of relative humidity  

E-Print Network [OSTI]

-type peanut seeds. Plant Physiol, 4. 5: 268-272. 26. Lyon, C. J. 1965. Auxin transport in geotropic curvalutss of a branched plant. Plant Physiol. 4. 0z 18-24. . 27. Marais, J, Pe y J. L. DeWit and G. V. Quicke. 1966. A critical examination of the Nelson...

Lee, Thomas Alonzo

1970-01-01T23:59:59.000Z

205

Size effect of hematite and corundum inclusions on the efflorescence relative humidities of aqueous ammonium nitrate particles  

E-Print Network [OSTI]

and Structure: Aerosols and particles (0345, 4801); 0345 Atmospheric Composition and Structure: Pollution ammonium nitrate particles Jeong-Ho Han Department of Environmental Chemistry, Atmospheric Science Division by the saturation of the aqueous solution with respect to the solid. INDEX TERMS: 0305 Atmospheric Composition

206

HVAC Design Strategy for a Hot-Humid Production Builder, Houston, Texas (Fact Sheet)  

SciTech Connect (OSTI)

BSC worked directly with the David Weekley Homes - Houston division to redesign three floor plans in order to locate the HVAC system in conditioned space. The purpose of this project is to develop a cost effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses. This is in preparation for the upcoming code changes in 2015. The builder wishes to develop an upgrade package that will allow for a seamless transition to the new code mandate. The following research questions were addressed by this research project: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost? BSC and the builder developed a duct design strategy that employs a system of dropped ceilings and attic coffers for moving the ductwork from the vented attic to conditioned space. The furnace has been moved to either a mechanical closet in the conditioned living space or a coffered space in the attic.

Not Available

2014-03-01T23:59:59.000Z

207

Approaches to 30% Energy Savings at the Community Scale in the Hot-Humid Climate  

SciTech Connect (OSTI)

BA-PIRC has worked with several community-scale builders within the hot humid climate zone to improve performance of production, or community scale, housing. Tommy Williams Homes (Gainesville, FL), Lifestyle Homes (Melbourne, FL), and Habitat for Humanity (various locations, FL) have all been continuous partners of the BA Program and are the subjects of this report to document achievement of the Building America goal of 30% whole house energy savings packages adopted at the community scale. The scope of this report is to demonstrate achievement of these goals though the documentation of production-scale homes built cost-effectively at the community scale, and modeled to reduce whole-house energy use by 30% in the Hot Humid climate region. Key aspects of this research include determining how to evolve existing energy efficiency packages to produce replicable target savings, identifying what builders' technical assistance needs are for implementation and working with them to create sustainable quality assurance mechanisms, and documenting the commercial viability through neutral cost analysis and market acceptance. This report documents certain barriers builders overcame and the approaches they implemented in order to accomplish Building America (BA) Program goals that have not already been documented in previous reports.

Thomas-Rees, S.; Beal, D.; Martin, E.; Fonorow, K.

2013-03-01T23:59:59.000Z

208

Heating, Ventilation, and Air Conditioning Design Strategy for a Hot-Humid Production Builder  

SciTech Connect (OSTI)

BSC worked directly with the David Weekley Homes - Houston division to redesign three floor plans in order to locate the HVAC system in conditioned space. The purpose of this project is to develop a cost effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses. This is in preparation for the upcoming code changes in 2015. The builder wishes to develop an upgrade package that will allow for a seamless transition to the new code mandate. The following research questions were addressed by this research project: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost? BSC and the builder developed a duct design strategy that employs a system of dropped ceilings and attic coffers for moving the ductwork from the vented attic to conditioned space. The furnace has been moved to either a mechanical closet in the conditioned living space or a coffered space in the attic.

Kerrigan, P.

2014-03-01T23:59:59.000Z

209

E-Print Network 3.0 - air monitor operating Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

& Biological Engineering Summary: ASREC Air temperatures and relative humidity, static pressure, heater, fogger and fan operation... economic stability and profitability...

210

Temperature & Nuclear Fusion 4 October 2011  

E-Print Network [OSTI]

Temperature & Nuclear Fusion 4 October 2011 Goals · Review temperature in stars · Practice using the important energy scales for nuclear fusion Temperature 1. For each relation we regularly use in class temperature. #12;temperature & nuclear fusion 2 Nuclear Fusion 2. There are a few different energy scales

Militzer, Burkhard

211

PARAMETRIC STUDY OF GROUND SOURCE HEAT PUMP SYSTEM FOR HOT AND HUMID CLMATE  

SciTech Connect (OSTI)

The U-tube sizes and varied thermal conductivity with different grout materials are studied based on the benchmark residential building in Hot-humid Pensacola, Florida. In this study, the benchmark building is metered and the data is used to validate the simulation model. And a list of comparative simulation cases with varied parameter value are simulated to study the importance of pipe size and grout to the ground source heat pump energy consumption. The simulation software TRNSYS [1] is employed to fulfill this task. The results show the preliminary energy saving based on varied parameters. Future work needs to be conducted for the cost analysis, include the installation cost from contractor and materials cost.

Jiang Zhu; Yong X. Tao

2011-11-01T23:59:59.000Z

212

Reducing Thermal Losses and Gains With Buried and Encapsulated Ducts in Hot-Humid Climates  

SciTech Connect (OSTI)

The Consortium for Advanced Residential Buildings (CARB) monitored three houses in Jacksonville, FL, to investigate the effectiveness of encapsulated and encapsulated/buried ducts in reducing thermal losses and gains from ductwork in unconditioned attics. Burying ductwork beneath loose-fill insulation has been identified as an effective method of reducing thermal losses and gains from ductwork in dry climates, but it is not applicable in humid climates where condensation may occur on the outside of the duct jacket. By encapsulating the ductwork in closed cell polyurethane foam (ccSPF) before burial beneath loose-fill mineral fiber insulation, the condensation potential may be reduced while increasing the R-value of the ductwork.

Shapiro, C.; Magee, A.; Zoeller, W.

2013-02-01T23:59:59.000Z

213

Impact of Residential Mechanical Ventilation on Energy Cost and Humidity Control  

SciTech Connect (OSTI)

The DOE Building America program has been conducting research leading to cost effective high performance homes since the early 1990's. Optimizing whole house mechanical ventilation as part of the program's systems engineered approach to constructing housing has been an important subject of the program's research. Ventilation in residential buildings is one component of an effective, comprehensive strategy for creation and maintenance of a comfortable and healthy indoor air environment. The study described in this white paper is based on building energy modeling with an important focus on the indoor humidity impacts of ventilation. The modeling tools used were EnergyPlus version 7.1 (E+) and EnergyGauge USA (EGUSA). Twelve U.S. cities and five climate zones were represented. A total of 864 simulations (2*2*3*3*12= 864) were run using two building archetypes, two building leakage rates, two building orientations, three ventilation systems, three ventilation rates, and twelve climates.

Martin, E.

2014-01-01T23:59:59.000Z

214

Efficient Multifamily Homes in a Hot-Humid Climate by Atlantic Housing Partners  

SciTech Connect (OSTI)

With assistance from the Florida Solar Energy Center (FSEC) and its Building America Partnership for Improved Residential Construction (BA-PIRC), Atlantic Housing Partners (AHP) has implemented a high performance, systems engineered package of measures. This report demonstrates how the initiative achieves Building America (BA) goals of 30%-50% energy savings. Specifically, the goals are documented as being achieved in the new construction multifamily housing sector in the hot humid climate. Results from energy modeling of the high performance package are presented. The role of utility allowance calculations, used as part of the low-income housing tax credit process, to value those energy savings is discussed, as is customer satisfaction with heat pump water heaters.

Chasar, D.; Martin, E.

2013-04-01T23:59:59.000Z

215

Exploring Cost-Effective, High Performance Residential Retrofits for Affordable Housing in the Hot Humid Climate  

SciTech Connect (OSTI)

In 2009, a Department of Energy Building America team led by the Florida Solar Energy Center began working with partners to find cost-effective paths for improving the energy performance of existing homes in the hot humid climate. A test-in energy audit and energy use modeling of the partner's proposed renovation package was performed for 41 affordable and middle income foreclosed homes in Florida and Alabama. HERS1 Indices ranged from 92 to 184 with modeled energy savings ranging from 3% to 50% (average of 26%). Analyses and recommendations were discussed with partners to encourage more efficient retrofits, highlight health and safety issues, and gather feedback on incremental cost of high performance measures. Ten completed renovations have modeled energy savings ranging from 9% to 48% (average 31%.) This paper presents the project's process including our findings thus far and highlights of the first home to meet the target HERS Index of 70.

McIlvaine, Janet; Sutherland, Karen; Schleith, Kevin; Chandra, Subrato

2010-08-27T23:59:59.000Z

216

Dynamic Analysis of Moisture Transport Through Walls and Associated Cooling Loads in the Hot/Humid Climate of Florianopolis, Brazil  

E-Print Network [OSTI]

on sunny and cloudy days. The weather used was a hot/humid summer period in Florian6polis (South Brazil). It is shown that neglecting moisture migration or assuming that the physical properties of wall materials do not depend on moisture content can result...

Mendes, N.; Winkelmann, F. C.; Lamberts, R.; Philippi, P. C.; Da Cunha, Neto, J. A. B.

1996-01-01T23:59:59.000Z

217

Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control: Report and Summary Report  

SciTech Connect (OSTI)

The primary objective of this project was to demonstrate the capabilities of a new high-performance, liquid-desiccant dedicated outdoor air system (DOAS) to enhance cooling efficiency and comfort in humid climates while substantially reducing electric peak demand at Tyndall Air Force Base (AFB), which is 12 miles east of Panama City, Florida.

Dean, J.; Kozubal, E.; Herrmann, L.; Miller, J.; Lowenstein, A.; Barker, G.; Slayzak, S.

2012-11-01T23:59:59.000Z

218

variability temperature  

E-Print Network [OSTI]

balance benguela biases buoyancy cod comparisons convection cooling energy error estimation fluctuations related relative remote resolution results sampling ships studies validation weather world approach pacificocean phase plankton predictability present principal shelf shift simulated southwest statistics

219

Investigations on Vapour Compression Air Conditioner with Direct Contact Desiccant Loop over Condenser and Evaporator  

E-Print Network [OSTI]

Perceived air quality increases when relative humidity is decreased till about 30% in the range of comfort temperature. In the present scenario, humidity is considered as a pollutant. Hence, a controlled environment not only at low temperature...

Maiya, M. P.; Ravi, J.; Tiwari, S.

2010-01-01T23:59:59.000Z

220

Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot-Humid Climate  

SciTech Connect (OSTI)

This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

Sutherland, K.; Martin, E.

2013-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Kinetics of the reaction of iron blast furnace slag/hydrated lime sorbents with SO{sub 2} at low temperatures: effects of the presence of CO{sub 2}, O{sub 2}, and NOx  

SciTech Connect (OSTI)

The effects of the presence of CO{sub 2}, O{sub 2}, and NOx in the flue gas on the kinetics of the sulfation of blast furnace slag/hydrated lime sorbents at low temperatures were studied using a differential fixed-bed reactor. When O{sub 2} and NOx were not present simultaneously, the reaction kinetics was about the same as that under the gas mixtures containing SO{sub 2}, H{sub 2}O, and N{sub 2} only, being affected mainly by the relative humidity. The sulfation of sorbents can be described by the surface coverage model and the model equations derived for the latter case. When both O{sub 2} and NOx, were present, the sulfation of sorbents was greatly enhanced, forming a great amount of sulfate in addition to sulfite. The surface coverage model is still valid in this case, but the model equations obtained show a more marked effect of relative humidity and negligible effects of SO{sub 2} concentration and temperature on the reaction. The effect of sorbent composition on the reaction kinetics was entirely represented by the effects of the initial specific surface area (S{sub g0}) and the Ca molar content (M{sup -1}) of sorbent. The initial conversion rate of sorbent increased linearly with increasing S{sub g0}, and the ultimate conversion increased linearly with increasing S{sub g0}M{sup -1}. The model equations obtained in this work are applicable to describe the kinetics of the sulfation of the sorbents in the low-temperature dry and semidry fine gas desulfurization processes either with an upstream NOx, removal unit or without.111

Liu, C.F.; Shih, S.M. [Industrial Technological Research Institute, Hsinchu (Taiwan)

2009-09-15T23:59:59.000Z

222

Indoor air movement acceptability and thermal comfort in hot-humid climates  

E-Print Network [OSTI]

and workload. Applied Ergonomics 32: 407- 417. [67]Journal of Industrial Ergonomics 3, 89 – 102. Brager, G.S. ,with equivalent temperatures, Ergonomics, 40, pp. 223 – 234.

Candido, Christhina Maria

2010-01-01T23:59:59.000Z

223

Temperature & Nuclear Fusion 4 October 2011  

E-Print Network [OSTI]

Temperature & Nuclear Fusion 4 October 2011 Goals · Review temperature in stars · Practice using the important energy scales for nuclear fusion Temperature 1. For each relation we regularly use in class-Boltzmann equation: L = 4R2 T4 . (d) In fusion energy generation: T . #12;temperature & nuclear fusion 2 Nuclear

Militzer, Burkhard

224

Plants for passive cooling. A preliminary investigation of the use of plants for passive cooling in temperate humid climates  

SciTech Connect (OSTI)

The potential of vegetation for cooling small, detached residential and commercial structures in temperate, humid climates is discussed. The results of the research are documented, a critical review of the literature is given, and a brief review of energy transfer processes is presented. A checklist of design objectives for passive cooling, a demonstration of design applications, and a palette of selected plant species suitable for passive cooling are included.

Spirn, A W; Santos, A N; Johnson, D A; Harder, L B; Rios, M W

1981-04-01T23:59:59.000Z

225

The Successful Design Construction and 'Live-ability' of an Energy Efficient Home in a Hot and Humid Climate  

E-Print Network [OSTI]

clothes washer null Energy Star Hunter ceiling fans null 90% of the lighting is fluorescent null Gas fired water heater with solar assist For those ten really cold days in winter we have a wood burning stove with catalytic converter to supplement...The Successful Design, Construction and “Live-ability” of an Energy Efficient Home in a Hot and Humid Climate John C. Gardner, PE Hockley, Texas 77447 ABSTRACT This paper will present a case study of an energy efficient home...

Gardner, J. C.

2006-01-01T23:59:59.000Z

226

Case Study of Stratified Chilled Water Storage Utilization for Comfort and Process Cooling in a Hot, Humid Climate  

E-Print Network [OSTI]

of the system and its operation is followed by presentation of operating data taken during 1997. INTRODUCTION Chilled water thermal energy storage ('TES) in naturally stratified tanks has been shown to be a valuable central cooling plant load management... and humid environment and presents new data on the performance of a large stratified chilled water storage tank. Figure 1. Plant Schematic. SITE The case study site is the Dallas, TX world headquarters of a major semiconductor manufacturer. The 6...

Bahnfleth, W. P.; Musser, A.

1998-01-01T23:59:59.000Z

227

Field Performance of A Compacted Clay Landfill Final cover At A Humid Site  

SciTech Connect (OSTI)

A study was conducted in southern Georgia, USA to evaluate how the hydraulic properties of the compacted clay barrier layer in a landfill final cover changed over a 4-yr service life. The cover was part of a test section constructed in a large drainage lysimeter that allowed CE Database subject headings: landfill, hydrogeology, compacted soils, lysimeters, desiccation continuous monitoring of the water balance. Patterns in the drainage (i.e., flow from the bottom of the cover) record suggest that preferential flow paths developed in the clay barrier soon after construction, apparently in response to desiccation cracking. After four years, the clay barrier was excavated and examined for changes in soil structure and hydraulic conductivity. Tests were conducted in situ with a sealed double-ring infiltrometer and two-stage borehole permeameters and in the laboratory on hand-carved blocks taken during construction and after four years of service. The in situ and laboratory tests indicated that the hydraulic conductivity increased approximately three orders of magnitude (from ? 10-7 to ? 10-4 cm s-1) during the service life. A dye tracer test and soil structure analysis showed that extensive cracking and root development occurred throughout the entire depth of the barrier layer. Laboratory tests on undisturbed specimens of the clay barrier indicated that the hydraulic conductivity of damaged clay barriers can be under-estimated significantly if small specimens (e.g., tube samples) are used for hydraulic conductivity assessment. The findings also indicate that clay barriers must be protected from desiccation and root intrusion if they are expected to function as intended, even at sites in warm, humid locations.

Albright, William H.; Benson, Craig H.; Gee, Glendon W.; Abichou, Tarek; Mcdonald, Eric V.; Tyler, Scott W.; Rock, Steven

2006-11-01T23:59:59.000Z

228

Beamline Temperatures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD)ProductssondeadjustsondeadjustAboutScience ProgramBackground8.0.1 PrintTemperatures Energy: 3.0000 GeV

229

Field-Evaluation of Alternative HVAC Strategies to Meet Ventilation, Comfort and Humidity Control Criteria at Three Full-Serve Restaurants  

E-Print Network [OSTI]

Lighting and ventilation represent the majority of the air conditioning loads in office buildings in hot humid climates. Use of motion sensors is one way to minimize the energy used for these loads. This paper describes the methods used...

Yborra, S. C.; Spears, J. W.

2000-01-01T23:59:59.000Z

230

Public Health-Related Impacts of Climate Change inCalifornia  

SciTech Connect (OSTI)

In June 2005 Governor Arnold Schwarzenegger issued Executive Order S-3-05 that set greenhouse gas emission reduction targets for California, and directed the Secretary of the California Environmental Protection Agency to report to the governor and the State legislature by January 2006 and biannually thereafter on the impacts to California of global warming, including impacts to water supply, public health, agriculture, the coastline, and forestry, and to prepare and report on mitigation and adaptation plans to combat these impacts. This report is a part of the report to the governor and legislature, and focuses on public health impacts that have been associated with climate change. Considerable evidence suggests that average ambient temperature is increasing worldwide, that temperatures will continue to increase into the future, and that global warming will result in changes to many aspects of climate, including temperature, humidity, and precipitation (McMichael and Githeko, 2001). It is expected that California will experience changes in both temperature and precipitation under current trends. Many of the changes in climate projected for California could have ramifications for public health (McMichael and Githeko, 2001), and this document summarizes the impacts judged most likely to occur in California, based on a review of available peer-reviewed scientific literature and new modeling and statistical analyses. The impacts identified as most significant to public health in California include mortality and morbidity related to temperature, air pollution, vector and water-borne diseases, and wildfires. There is considerable complexity underlying the health of a population with many contributing factors including biological, ecological, social, political, and geographical. In addition, the relationship between climate change and changes in public health is difficult to predict for the most part, although more detailed information is available on temperature-related mortality and air pollution effects than the other endpoints discussed in this document. Consequently, these two topics are discussed in greater detail. Where possible, estimates of the magnitude and significance of these impacts are also discussed, along with possible adaptations that could reduce climate-related health impacts. In the context of this review, weather refers to meteorological conditions at a specific place and time over a relatively short time frame, such as up to a year or two. Climate, on the other hand, refers to the same meteorological conditions, but over a longer time frame, such as decades or centuries.

Drechsler, D.M.; Motallebi, N.; Kleeman, M.; Cayan, D.; Hayhoe,K.; Kalkstein, L.S.; Miller, N.L.; Jin, J.; VanCuren, R.A.

2005-12-01T23:59:59.000Z

231

Residential Slab-On-Grade Heat Transfer in Hot Humid Climates  

E-Print Network [OSTI]

Heat transfer through an uninsulated slab on grade is calculated using a simple method developed by Kusuda. The seasonal and annual slab loads are graphed as a function of annual average soil temperature, Tm, for a variety of floor system...

Clark, E.; Ascolese, M.; Collins, W.

1989-01-01T23:59:59.000Z

232

Thermal and lighting performance of toplighting systems in the hot and humid climate of Thailand  

E-Print Network [OSTI]

performance of three toplighting systems were compared. For the thermal performance, total cooling loads, heat gains and losses, and interior temperature were evaluated. The lighting performance parameters examined were daylight factor, illuminance level...

Harntaweewongsa, Siritip

2006-10-30T23:59:59.000Z

233

Quantum Chemistry at Finite Temperature  

E-Print Network [OSTI]

In this article, we present emerging fields of quantum chemistry at finite temperature. We discuss its recent developments on both experimental and theoretical fronts. First, we describe several experimental investigations related to the temperature effects on the structures, electronic spectra, or bond rupture forces for molecules. These include the analysis of the temperature impact on the pathway shifts for the protein unfolding by atomic force microscopy (AFM), the temperature dependence of the absorption spectra of electrons in solvents, and the temperature influence over the intermolecular forces measured by the AFM. On the theoretical side, we review advancements made by the author in the coming fields of quantum chemistry at finite temperature. Starting from the Bloch equation, we have derived the sets of hierarchy equations for the reduced density operators in both canonical and grand canonical ensembles. They provide a law according to which the reduced density operators vary in temperature for the identical and interacting many-body systems. By taking the independent particle approximation, we have solved the equations in the case of a grand canonical ensemble, and obtained an energy eigenequation for the molecular orbitals at finite temperature. The explicit expression for the temperature-dependent Fock operator is also given. They form a mathematical foundation for the examination of the molecular electronic structures and their interplay with finite temperature. Moreover, we clarify the physics concerning the temperature effects on the electronic structures or processes of the molecules, which is crucial for both theoretical understanding and computation. Finally, ....

Liqiang Wei

2006-05-23T23:59:59.000Z

234

Building America Case Study: Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana (Fact Sheet)  

SciTech Connect (OSTI)

This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA. Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

Not Available

2014-11-01T23:59:59.000Z

235

This article was downloaded by: [Adrian Tuck] On: 22 August 2011, At: 11:16  

E-Print Network [OSTI]

://www.tandfonline.com/loi/tres20 Vertical scaling of temperature, wind and humidity fluctuations: dropsondes from 13 km Journal of Remote Sensing iFirst, 2011, 1­28 Vertical scaling of temperature, wind and humidity from research dropsondes for temperature, wind speed and relative humidity during the 800 s it takes

Lovejoy, Shaun

236

Optical Properties of Moderately-Absorbing Organic and Mixed Organic/Inorganic Particles at Very High Humidities  

SciTech Connect (OSTI)

Relative humidity (RH) affects the water content of an aerosol, altering its ability to scatter and absorb light, which is important for aerosol effects on climate and visibility. This project involves in situ measurement and modeling of aerosol optical properties including absorption, scattering and extinction at three visible wavelengths (467, 530, 660 nm), for organic carbon (OC) generated by pyrolysis of biomass, ammonium sulfate and sodium chloride, and their mixtures at controlled RH conditions. Novel components of this project include investigation of: (1) Changes in all three of these optical properties at scanned RH conditions; (2) Optical properties at RH values up to 95%, which are usually extrapolated instead of measured; and (3) Examination of aerosols generated by the pyrolysis of wood, which is representative of primary atmospheric organic carbon, and its mixture with inorganic aerosol. Scattering and extinction values were used to determine light absorption by difference and single scattering albedo values. Extensive instrumentation development and benchmarking with independently measured and modeled values were used to obtain and evaluate these new results. The single scattering albedo value for a dry absorbing polystyrene microsphere benchmark agreed within 0.02 (absolute value) with independently published results at 530 nm. Light absorption by a nigrosin (sample light-absorbing) benchmark increased by a factor of 1.24 +/-0.06 at all wavelengths as RH increased from 38 to 95%. Closure modeling with Mie theory was able to reproduce this increase with the linear volume average (LVA) refractive index mixing rule for this water soluble compound. Absorption by biomass OC aerosol increased by a factor of 2.1 +/- 0.7 and 2.3 +/- 1.2 between 32 and 95% RH at 467 nm and 530 nm, but there was no detectable absorption at 660 nm. Additionally, the spectral dependence of absorption by OC that was observed with filter measurements was confirmed qualitatively in situ at 467 and 530 nm. Closure modeling with the dynamic effective medium approximation (DEMA) refractive index model was able to capture the increasing absorption trend with RH indicating that the droplets were heterogeneously mixed while containing dispersed insoluble absorbing material within those droplets. Seven other refractive index mixing models including LVA did not adequately describe the measurements for OC. Mixing the biomass OC aerosol with select mass fractions of ammonium sulfate ranging from 25 to 36% and sodium chloride ranging from 21 to 30% resulted in an increase in light scattering and extinction with RH and inorganic mass fraction. However, no detectable difference in light absorption behavior in comparison to pure biomass OC was observed. The main finding of this research is a measured increase in absorption with increasing RH, which is currently not represented in radiative transfer models even though biomass burning produces most of the primary OC aerosol in the atmosphere.

Bond, Tami C; Rood, Mark J; Brem, Benjamin T; Mena-Gonzalez, Francisco C; Chen, Yanju

2012-04-16T23:59:59.000Z

237

Apparatus for adjusting and maintaining the humidity of gas at a constant value within a closed system  

DOE Patents [OSTI]

The humidity of a gas within a closed system is maintained at constant level by providing a saturated salt solution within a lower chamber in communication with an upper chamber conjointly defined by upper and lower container sections in sealing contact with each other to establish a closed container. A partition wall separates the salt solution from the test region in the upper chamber. A tube extending through the partition plate allows humidified gas to pass from the lower to the upper chamber. A glass wool plug or membranous material within the tube prevents migration of salt into the test region.

Abernathy, B.R.; Walters, R.R.

1985-08-05T23:59:59.000Z

238

Building a 40% Energy Saving House in the Mixed-Humid Climate  

SciTech Connect (OSTI)

This report describes a home that uses 40% less energy than the energy-efficient Building America standard - a giant step in the pursuit of affordable near-zero-energy housing through the evolution of five near-zero-energy research houses. This four-bedroom, two-bath, 1232-ft2 house has a Home Energy Rating System (HERS) index of 35 (a HERS rating of 0 is a zero-energy house, a conventional new house would have a HERS rating of 100), which qualifies it for federal energy efficiency and solar incentives. The house is leading to the planned construction of a similar home in Greensburg, Kansas, and 21 staff houses in the Walden Reserve, a 7000-unit "deep green" community in Cookville, Tennessee. Discussions are underway for construction of similar houses in Charleston, South Carolina, Seattle, Washington, Knoxville and Oak Ridge, Tennessee, and upstate New York. This house should lead to a 40% and 50% Gate-3, Mixed-Humid-Climate Joule for the DOE Building America Program. The house is constructed with structurally-insulated-panel walls and roof, raised metal-seam roof with infrared reflective coating, airtight envelope (1.65 air changes per hour at 50 Pascal), supply mechanical ventilation, ducts inside the conditioned space, extensive moisture control package, foundation geothermal space heating and cooling system, ZEHcor wall, solar water heater, and a 2.2 kWp grid-connected photovoltaic (PV) system. The detailed specifications for the envelope and the equipment used in ZEH5 compared to all the houses in this series are shown in Tables 1 and 2. Based on a validated computer simulation of ZEH5 with typical occupancy patterns and energy services for four occupants, energy for this all-electric house is predicted to cost only $0.66/day ($0.86/day counting the hookup charges). By contrast, the benchmark house would require $3.56/day, including hookup charges (these costs are based on a 2006 residential rates of $0.07/kWh and solar buyback at $0.15/kWh). The solar fraction for this home located in Lenoir City, Tennessee, is predicted to be as high as 41%(accounting for both solar PV and the solar water heater). This all-electric home is predicted to use 25 kWh/day based on the one year of measured data used to calibrate a whole-building simulation model. Based on two years of measured data, the roof-mounted 2.2 kWp PV system is predicted to generate 7.5 kWh/day. The 2005 cost to commercially construct ZEH5, including builder profit and overhead, is estimated at about $150,000. This cost - for ZEH5's panelized construction, premanufactured utility wall (ZEHcor), foundation geothermal system, and the addition of the walkout lower level, and considering the falling cost for PV - suggests that the construction cost per ft2 for a ZEH5 two-story will be even more cost-competitive. The 2005 construction cost estimate for a finished-out ZEH5 with 2632 ft2 is $222,000 or $85/ft2. The intention of this report is to help builders and homeowners make the decision to build zero-energy-ready homes. Detailed drawings, specifications, and lessons learned in the construction and analysis of data from about 100 sensors monitoring thermal performance for a one-year period are presented. This information should be specifically useful to those considering structural insulated panel walls and roof, foundation geothermal space heating and cooling, solar water heater and roof-mounted, photovoltaic, grid-tied systems.

Christian, Jeffrey E [ORNL; Bonar, Jacob [ORNL

2011-10-01T23:59:59.000Z

239

High Temperatures & Electricity Demand  

E-Print Network [OSTI]

High Temperatures & Electricity Demand An Assessment of Supply Adequacy in California Trends.......................................................................................................1 HIGH TEMPERATURES AND ELECTRICITY DEMAND.....................................................................................................................7 SECTION I: HIGH TEMPERATURES AND ELECTRICITY DEMAND ..........................9 BACKGROUND

240

Drexel University Temperature Sensors  

SciTech Connect (OSTI)

This document summarizes background information and presents results related to temperature measurements in the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) Drexel University Project 31091 irradiation. The objective of this test was to assess the radiation performance of new ceramic materials for advanced reactor applications. Accordingly, irradiations of transition metal carbides and nitrides were performed using the Hydraulic Shuttle Irradiation System (HSIS) in the B-7 position and in static capsules inserted into the A-3 and East Flux Trap Position 5 locations of the ATR.

K. L. Davis; D. L. Knudson; J. L. Rempe; B. M. Chase

2014-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Metal-air low temperature ionic liquid cell  

DOE Patents [OSTI]

The present application relates to an electrochemical metal-air cell in which a low temperature ionic liquid is used.

Friesen, Cody A; Buttry, Daniel A

2014-11-25T23:59:59.000Z

242

Method for measuring surface temperature  

SciTech Connect (OSTI)

The present invention relates to a method for measuring a surface temperature using is a fluorescent temperature sensor or optical thermometer. The sensor includes a solution of 1,3-bis(1-pyrenyl)propane within a 1-butyl-1-1-methyl pyrrolidinium bis(trifluoromethylsulfonyl)imide ionic liquid solvent. The 1,3-bis(1-pyrenyl)propane remains unassociated when in the ground state while in solution. When subjected to UV light, an excited state is produced that exists in equilibrium with an excimer. The position of the equilibrium between the two excited states is temperature dependent.

Baker, Gary A. (Los Alamos, NM); Baker, Sheila N. (Los Alamos, NM); McCleskey, T. Mark (Los Alamos, NM)

2009-07-28T23:59:59.000Z

243

Influence of annual windbreak on the water relations, growth and yield of cotton and peanuts  

E-Print Network [OSTI]

in monitoring of microclimate. Instrument Parameter and Units Manufacturer and Model Anemometer windspeed (ms ~) R. M. Young Gi11 3-cup anemom- eter Model 12102 Pyranometer Temperature Sensor Humidity Sensor Datalogger solar radiation ! Langleys... in turbulence or vertical air movement . Water vapor tr ansfer, heat and gaseous exchanges are affected by both the horizontal and vertical movement of the air. Since wi ndbreaks reduce wi ndspeed and turbulence, the rate of removal of water vapor and heat...

Waweru, Francis Mbote

2012-06-07T23:59:59.000Z

244

Investigation of charge compensation in indium-doped tin dioxide by hydrogen insertion via annealing under humid conditions  

SciTech Connect (OSTI)

The behavior of hydrogen (H) as an impurity in indium (In)-doped tin dioxide (SnO{sub 2}) was investigated by mass spectrometry analyses, with the aim of understanding the charge compensation mechanism in SnO{sub 2}. The H-concentration of the In-doped SnO{sub 2} films increased to (1–2)?×?10{sup 19}?cm{sup ?3} by annealing in a humid atmosphere (WET annealing). The electron concentration in the films also increased after WET annealing but was two orders of magnitude less than their H-concentrations. A self-compensation mechanism, based on the assumption that H sits at substitutional sites, is proposed to explain the mismatch between the electron- and H-concentrations.

Watanabe, Ken, E-mail: Watanabe.Ken@nims.go.jp [National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); International Center for Young Scientists (ICYS-MANA), NIMS, 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); Ohsawa, Takeo; Ross, Emily M., E-mail: emross@hmc.edu; Adachi, Yutaka; Haneda, Hajime [National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); Sakaguchi, Isao; Takahashi, Ryosuke [National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); Department of Applied Science for Electronics and Materials, Kyushu University, 6-1 Kasuga-kouen Kasuga, Fukuoka 816-8580 (Japan); Bierwagen, Oliver, E-mail: bierwagen@pdi-berlin.de [Paul-Drude-Institute, Hausvogteiplatz 5-7, 10117 Berlin (Germany); Materials Department, University of California, Santa Barbara, California 93106 (United States); White, Mark E.; Tsai, Min-Ying; Speck, James S., E-mail: speck@ucsb.edu [Materials Department, University of California, Santa Barbara, California 93106 (United States); Ohashi, Naoki, E-mail: Ohashi.Naoki@nims.go.jp [National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); Department of Applied Science for Electronics and Materials, Kyushu University, 6-1 Kasuga-kouen Kasuga, Fukuoka 816-8580 (Japan); Materials Research Center for Element Strategy (MCES), Mailbox S2-13, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama 226-0026 (Japan)

2014-03-31T23:59:59.000Z

245

Water vapor and temperature inversions near the 0 deg C level over the tropical western Pacific. Master's thesis  

SciTech Connect (OSTI)

During the Intensive Observation Period (IOP), several periods of water vapor and temperature inversions near the 0 deg C level were observed. Satellite and radiosonde data from TOGA COARE are used to document the large-scale conditions and thermodynamic and kinematic structures present during three extended periods in which moisture and temperature inversions near the freezing level were very pronounced. Observations from each case are synthesized into schematics which represent typical structures of the inversion phenomena. Frequency distributions of the inversion phenomena along with climatological humidity and temperature profiles are calculated for the four-month IOP.

Hart, K.A.

1994-01-01T23:59:59.000Z

246

Low-temperature magnetic refrigerator  

DOE Patents [OSTI]

The invention relates to magnetic refrigeration and more particularly to low temperature refrigeration between about 4 and about 20 K, with an apparatus and method utilizing a belt of magnetic material passed in and out of a magnetic field with heat exchangers within and outside the field operably disposed to accomplish refrigeration.

Barclay, J.A.

1983-05-26T23:59:59.000Z

247

High temperature turbine engine structure  

DOE Patents [OSTI]

A high temperature turbine engine includes a rotor portion having axially stacked adjacent ceramic rotor parts. A ceramic/ceramic joint structure transmits torque between the rotor parts while maintaining coaxial alignment and axially spaced mutually parallel relation thereof despite thermal and centrifugal cycling.

Boyd, Gary L. (Tempe, AZ)

1991-01-01T23:59:59.000Z

248

The effect of temperature and time on the mechanical properties of lightly milled rice  

E-Print Network [OSTI]

MATERIALS AND EQUIPMENT Test Apparatus Dynamic Relative Humidity System PROCEDURE Milling and Equilibrating the R1ce Grain Compression Experiments Tension Experiments 10 10 12 14 15 16 Determination of Strength during Noisture Adsorption... TENSION LOADING OF BLUEBELLE LIGHTLY MILLED RICE 2 RESULTS FROM COMPRESSION LOADING OF BLUEBELLE LIGHTLY MILLED RICE 3 RESULTS FROM LOADING OF BLUEBELLE LIGHTLY MILLED RICE IN DIFFERENT POSITIONS 27 28 47 LIST OF FIGURES Figure Page Arrangement...

Maa, Tsorng-Jong

1974-01-01T23:59:59.000Z

249

Relational EPR  

E-Print Network [OSTI]

We study the EPR-type correlations from the perspective of the relational interpretation of quantum mechanics. We argue that these correlations do not entail any form of 'non-locality', when viewed in the context of this interpretation. The abandonment of strict Einstein realism implied by the relational stance permits to reconcile quantum mechanics, completeness, (operationally defined) separability, and locality.

Matteo Smerlak; Carlo Rovelli

2006-04-10T23:59:59.000Z

250

These are practically rainless but persistently cool and humid because of foggy air drifting off the cold offshore current. The California Coast in summer  

E-Print Network [OSTI]

and humid because of foggy air drifting off the cold offshore current. The California Coast in summer is oxidized to red rust. The Welwichia plant is a strange conifer with two giant flat leaves. You can find a couple in the desert section of the Plant Science teaching greenhouse, which we visit on an upcoming

Richerson, Peter J.

251

Analysis of Energy, Environmental and Life Cycle Cost Reduction Potential of Ground Source Heat Pump (GSHP) in Hot and Humid Climate  

Broader source: Energy.gov [DOE]

Project objectives: Gather and analyze independently the available technical, cost, financial incentive data on installed GSHP/HGSHP applications in residential, commercial and schools in hot and humid climate regions, and develop a calibrated baseline and performance period model of new construction and retrofitted buildings in conjunction with the energy simulation program.

252

Bay Ridge Gardens - Mixed-Humid Affordable Multifamily Housing Deep Energy Retrofit  

SciTech Connect (OSTI)

Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a 'base scope' retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a 'DER scope' which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

Lyons, J.; Moore, M.; Thompson, M.

2013-08-01T23:59:59.000Z

253

Achieving Challenge Home in Affordable Housing in the Hot-Humid Climate  

SciTech Connect (OSTI)

The Building America Partnership for Improved Residential Construction (BA-PIRC), one of the Building America research team leads, has partnered with two builders as they work through the Challenge Home certification process in one test home each. The builder partners participating in this cost-shared research are Southeast Volusia County Habitat for Humanity near Daytona, Florida and Manatee County Habitat for Humanity near Tampa, Florida. Both are affiliates of Habitat for Humanity International, a non-profit affordable housing organization. This research serves to identify viable technical pathways to meeting the CH criteria for other builders in the region. A further objective of this research is to identify gaps and barriers in the marketplace related to product availability, labor force capability, code issues, cost effectiveness, and business case issues that hinder or prevent broader adoption on a production scale.

Beal, D.; McIlvaine, J.; Winter, B.; Allnutt, R.

2014-08-01T23:59:59.000Z

254

Impact of Relative Humidity on the Survival of Desiccated Salmonella Cells on Surfaces with Peanut Butter Haiping Li, Christina Megalis, Mary Lou Tortorello  

E-Print Network [OSTI]

assessment of current post harvest and nut butter processing practices, and the development of best practices cases. Environmental samples tested positive in two recent outbreaks associated with nuts. In the 2006 Salmonella peanut butter outbreak, two environmental samples, one from a floor swab and another from

Heller, Barbara

255

Curie temperature of multiphase nanostructures  

SciTech Connect (OSTI)

The Curie temperature and the local spontaneous magnetization of ferromagnetic nanocomposites are investigated. The macroscopic character of the critical fluctuations responsible for the onset of ferromagnetic order means that there is only one Curie temperature, independent of the number of magnetic phases present. The Curie temperature increases with the grain size and is, in general, larger than predicted from the volume averages of the exchange constants. However, the Curie-temperature enhancement is accompanied by a relative reduction of the spontaneous magnetization. Due to the quadratic dependence of the permanent-magnet energy product on the spontaneous magnetization, this amounts to a deterioration of the magnets performance. The length scale on which an effective intergranular exchange coupling is realized (coupling length) depends on the Curie-temperature difference between the phases and on the spacial distribution of the local interatomic exchange. As a rule, it is of the order of a few interatomic distances; for much bigger grain sizes the structures mimic an interaction-free ensemble of different ferromagnetic materials. This must be compared to the magnetic-anisotropy coupling length, which is of the order of 10 nm. The difference is explained by the nonrelativistic character of the Curie-temperature problem. (c) 2000 American Institute of Physics.

Skomski, R. [Department of Physics and Astronomy and Center for Materials Research and Analysis, University of Nebraska, Lincoln, Nebraska 68588 (United States)] [Department of Physics and Astronomy and Center for Materials Research and Analysis, University of Nebraska, Lincoln, Nebraska 68588 (United States); Sellmyer, D. J. [Department of Physics and Astronomy and Center for Materials Research and Analysis, University of Nebraska, Lincoln, Nebraska 68588 (United States)] [Department of Physics and Astronomy and Center for Materials Research and Analysis, University of Nebraska, Lincoln, Nebraska 68588 (United States)

2000-05-01T23:59:59.000Z

256

Optimizing Cooling Tower Performance Refrigeration Systems, Chemical Plants, and Power Plants All Have A Resource Quietly Awaiting Exploitation-Cold Water!!  

E-Print Network [OSTI]

requirements before a cooling tower is purchased. This relates to the volume of circulating water, hot water temperature on the tower, cold water discharge, and wet bulb temperature (consisting of ambient temperature and relative humidity). After the tower...

Burger, R.

257

Temperature and electrical memory of polymer fibers  

SciTech Connect (OSTI)

We report in this work studies of the shape memory behavior of polymer fibers loaded with carbon nanotubes or graphene flakes. These materials exhibit enhanced shape memory properties with the generation of a giant stress upon shape recovery. In addition, they exhibit a surprising temperature memory with a peak of generated stress at a temperature nearly equal to the temperature of programming. This temperature memory is ascribed to the presence of dynamical heterogeneities and to the intrinsic broadness of the glass transition. We present recent experiments related to observables other than mechanical properties. In particular nanocomposite fibers exhibit variations of electrical conductivity with an accurate memory. Indeed, the rate of conductivity variations during temperature changes reaches a well defined maximum at a temperature equal to the temperature of programming. Such materials are promising for future actuators that couple dimensional changes with sensing electronic functionalities.

Yuan, Jinkai; Zakri, Cécile; Grillard, Fabienne; Neri, Wilfrid; Poulin, Philippe [Centre de Recherche Paul Pascal - CNRS, University of Bordeaux, Avenue Schweitzer, 33600 Pessac (France)

2014-05-15T23:59:59.000Z

258

Integrated Emissivity And Temperature Measurement  

DOE Patents [OSTI]

A multi-channel spectrometer and a light source are used to measure both the emitted and the reflected light from a surface which is at an elevated temperature relative to its environment. In a first method, the temperature of the surface and emissivity in each wavelength is calculated from a knowledge of the spectrum and the measurement of the incident and reflected light. In the second method, the reflected light is measured from a reference surface having a known reflectivity and the same geometry as the surface of interest and the emitted and the reflected light are measured for the surface of interest. These measurements permit the computation of the emissivity in each channel of the spectrometer and the temperature of the surface of interest.

Poulsen, Peter (Livermore, CA)

2005-11-08T23:59:59.000Z

259

Integrated and Optimized Energy-Efficient Construction Package for a Community of Production Homes in the Mixed-Humid Climate  

SciTech Connect (OSTI)

Selection and integration of high performance home features are two sides of the same coin in energy efficient sustainable construction. Many advanced technologies are available for selection, but it is in the integration of these technologies into an affordable set of features that can be used on a production basis by builders, that ensures whole-house performance meets expectations. This research high performance home analyzes how a set of advanced technologies can be integrated into a durable and energy efficient house in the mixed-humid climate while remaining affordable to homeowners. The technical solutions documented in this report are the cornerstone of the builder's entire business model based on delivering high-performance homes on a production basis as a standard product offering to all price segments of the residential market. Home Innovation Research Labs partnered with production builder Nexus EnergyHomes (CZ 4). The builder plans to adopt the successful components of the energy solution package for all 55 homes in the community. The research objective was to optimize the builder's energy solution package based on energy performance and construction costs. All of the major construction features, including envelope upgrades, space conditioning system, hot water system, and solar electric system were analyzed. The information in this report can be used by builders and designers to evaluate options, and the integration of options, for increasing the efficiency of home designs in climate zone 4. The data also provide a point of reference for evaluating estimates of energy savings and costs for specific features.

Mallay, D.; Wiehagen, J.; Del Bianco, M.

2014-10-01T23:59:59.000Z

260

Performance Verification of Production-Scalable Energy-Efficient Solutions: Winchester/Camberley Homes Mixed-Humid Climate  

SciTech Connect (OSTI)

Winchester/Camberley Homes with the Building America program and its NAHB Research Center Industry Partnership collaborated to develop a new set of high performance home designs that could be applicable on a production scale. The new home designs are to be constructed in the mixed humid climate zone four and could eventually apply to all of the builder's home designs to meet or exceed future energy codes or performance-based programs. However, the builder recognized that the combination of new wall framing designs and materials, higher levels of insulation in the wall cavity, and more detailed air sealing to achieve lower infiltration rates changes the moisture characteristics of the wall system. In order to ensure long term durability and repeatable successful implementation with few call-backs, this report demonstrates through measured data that the wall system functions as a dynamic system, responding to changing interior and outdoor environmental conditions within recognized limits of the materials that make up the wall system. A similar investigation was made with respect to the complete redesign of the heating, cooling, air distribution, and ventilation systems intended to optimize the equipment size and configuration to significantly improve efficiency while maintaining indoor comfort. Recognizing the need to demonstrate the benefits of these efficiency features, the builder offered a new house model to serve as a test case to develop framing designs, evaluate material selections and installation requirements, changes to work scopes and contractor learning curves, as well as to compare theoretical performance characteristics with measured results.

Mallay, D.; Wiehagen, J.

2014-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Temperature behavior in the build section of multilateral wells  

E-Print Network [OSTI]

. The model predicts the temperature profiles in the build sections connecting the laterals to one another or to a main wellbore, thus accounting for the changing well angle relative to the temperature profile in the earth. In addition, energy balance...

Romero Lugo, Analis Alejandra

2005-11-01T23:59:59.000Z

262

Plant Physiology Data, Barrow, Alaska, 2013  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Survey measurements of photosynthetic rate and stomatal conductance together with carbon dioxide concentration, temperature, PAR, and relative humidity for 8 species on the BEO.

Alistair Rogers

263

Demand response enabling technology development  

E-Print Network [OSTI]

global and diffuse solar radiation sensors, wind directionfrom a crude radiation sensor. Solar Radiation Conductiosensor data (Temperature, motion, relative humidity, solar

Arens, Edward; Auslander, David; Huizenga, Charlie

2008-01-01T23:59:59.000Z

264

australian tropical savannas: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

results in warmer and drier climate of tropical savannas increases temperatures and wind speeds and decreases precipitation and relative humidity Jackson, Robert B. 2...

265

THE TEMPERATURES OF RED SUPERGIANTS  

SciTech Connect (OSTI)

We present a re-appraisal of the temperatures of red supergiants (RSGs) using their optical and near-infrared spectral energy distributions (SEDs). We have obtained data of a sample of RSGs in the Magellanic Clouds using VLT+XSHOOTER, and we fit MARCS model atmospheres to different regions of the spectra, deriving effective temperatures for each star from (1) the TiO bands, (2) line-free continuum regions of the SEDs, and (3) the integrated fluxes. We show that the temperatures derived from fits to the TiO bands are systematically lower than the other two methods by several hundred kelvin. The TiO fits also dramatically overpredict the flux in the near-IR, and imply extinctions which are anomalously low compared to neighboring stars. In contrast, the SED temperatures provide good fits to the fluxes at all wavelengths other than the TiO bands, are in agreement with the temperatures from the flux integration method, and imply extinctions consistent with nearby stars. After considering a number of ways to reconcile this discrepancy, we conclude that three-dimensional effects (i.e., granulation) are the most likely cause, as they affect the temperature structure in the upper layers where the TiO lines form. The continuum, however, which forms at much deeper layers, is apparently more robust to such effects. We therefore conclude that RSG temperatures are much warmer than previously thought. We discuss the implications of this result for stellar evolution and supernova progenitors, and provide relations to determine the bolometric luminosities of RSGs from single-band photometry.

Davies, Ben [Astrophysics Research Institute, Liverpool John Moores University, Egerton Wharf, Birkenhead CH41 1LD (United Kingdom)] [Astrophysics Research Institute, Liverpool John Moores University, Egerton Wharf, Birkenhead CH41 1LD (United Kingdom); Kudritzki, Rolf-Peter; Gazak, Zach [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States)] [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States); Plez, Bertrand [Laboratoire Univers et Particules de Montpellier, Universite Montpellier 2, CNRS, F-34095 Montpellier (France)] [Laboratoire Univers et Particules de Montpellier, Universite Montpellier 2, CNRS, F-34095 Montpellier (France); Trager, Scott [Kapteyn Institute, University of Groningen, P.O. Box 800, 9700-AV Groningen (Netherlands)] [Kapteyn Institute, University of Groningen, P.O. Box 800, 9700-AV Groningen (Netherlands); Lancon, Ariane [Observatoire Astronomique and CNRS UMR 7550, Universite de Strasbourg, F-67000 Strasbourg (France)] [Observatoire Astronomique and CNRS UMR 7550, Universite de Strasbourg, F-67000 Strasbourg (France); Bergemann, Maria [Max-Planck-Institute for Astrophysics, Karl-Schwarzschild-Str. 1, D-85741 Garching (Germany)] [Max-Planck-Institute for Astrophysics, Karl-Schwarzschild-Str. 1, D-85741 Garching (Germany); Evans, Chris [UK Astronomy Technology Centre, Royal Observatory Edinburgh, Blackford Hill, Edinburgh EH9 3HJ (United Kingdom)] [UK Astronomy Technology Centre, Royal Observatory Edinburgh, Blackford Hill, Edinburgh EH9 3HJ (United Kingdom); Chiavassa, Andrea [CNRS Laboratoire Lagrange, Universite de Nice Sophia-Antipolis, Observatoire de la Cote d'Azur, BP 4229, F-06304 Nice Cedex 4 (France)] [CNRS Laboratoire Lagrange, Universite de Nice Sophia-Antipolis, Observatoire de la Cote d'Azur, BP 4229, F-06304 Nice Cedex 4 (France)

2013-04-10T23:59:59.000Z

266

The temperature dependence of equilibrium plasma density  

E-Print Network [OSTI]

Temperature dependence of an electron-nuclear plasma equilibrium density is considered basing on known approaches, which are given in (1)(2). It is shown that at a very high temperature, which is characteristic for a star interior, the equilibrium plasma density is almost constant and equals approximately to $10^{25}$ particles per $cm^3$. At a relatively low temperature, which is characteristic for star surface, the equilibrium plasma density is in several orders lower and depends on temperature as $T^{3/2}$.

B. V. Vasiliev

2002-03-17T23:59:59.000Z

267

Strings at finite temperature  

SciTech Connect (OSTI)

We obtain a semiclassical evaluation of the temperature for which the free energy of the strings of spontaneously broken scalar electrodynamics vanishes. We argue that, above this temperature, these objects should play a significant physical role.

Arago C. de; Bazeia, D.; Eboli, O.J.P.; Marques, G.C.

1985-12-15T23:59:59.000Z

268

Complementary Relativity  

E-Print Network [OSTI]

Special theory of relativity has been formulated in a vacuum momentum-energy representation which is equivalent to Einstein special relativity and predicts just the same results as it. Although in this sense such a formulation would be at least classically useless, its consistent extension to noninertial frames produces a momentum-energy metric which behaves as a new dynamical quantity that is here interpreted in terms of a cosmological field. This new field would be complementary to gravity in that its strength varies inversely to as that of gravity does. Using a strong-field approximation, we suggest that the existence of this cosmological field would induce a shift of luminous energy which could justify the existence of all the assumed invisible matter in the universe, so as the high luminousities found in active galactic nuclei and quasars.

P. F. Gonzalez-Diaz

1994-04-07T23:59:59.000Z

269

6, 13011320, 2006 Temperature  

E-Print Network [OSTI]

ACPD 6, 1301­1320, 2006 Temperature climatology and trend estimates over Durban, South Africa H and Physics Discussions Temperature climatology and trend estimates in the UTLS region as observed over Commons License. 1301 #12;ACPD 6, 1301­1320, 2006 Temperature climatology and trend estimates over Durban

Boyer, Edmond

270

Kinetics of combustion related processes at high temperatures  

SciTech Connect (OSTI)

This past year has seen an excursion into perhalomethane dissociation using the laser-schlieren (LS) technique, with work on CCl{sub 4} already published and on CF{sub 3}Cl under analysis. However, the author`s emphasis has again been on the study of relaxation and dissociation of large molecules using the converging/diverging nozzle method to generate very weak (low pressure) shock waves.

Kiefer, J.H. [Univ. of Illinois, Chicago (United States)

1993-12-01T23:59:59.000Z

271

Building America Best Practices Series Volume 15: 40% Whole-House Energy Savings in the Hot-Humid Climate  

SciTech Connect (OSTI)

This best practices guide is the 15th in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-humid climate can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and those requirements are highlighted in the text. Requirements of the 2012 IECC and 2012 IRC are also noted in text and tables throughout the guide. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.; Cole, Pamala C.; Adams, Karen; Noonan, Christine F.

2011-09-01T23:59:59.000Z

272

Building America Best Practices Series Volume 16: 40% Whole-House Energy Savings in the Mixed-Humid Climate  

SciTech Connect (OSTI)

This best practices guide is the 16th in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the mixed-humid climate can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and those requirements are highlighted in the text. Requirements of the 2012 IECC and 2012 IRC are also noted in text and tables throughout the guide. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.; Cole, Pamala C.; Adams, Karen; Butner, Ryan S.; Ortiz, Sallie J.

2011-09-01T23:59:59.000Z

273

Investor Relations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert Southwest Region service area.PortaldefaultIntroducing AuroraInvestor Relations

274

Improvements in Shallow (Two-Meter) Temperature Measurements...  

Open Energy Info (EERE)

to study influences on shallow temperature measurements related to geological and solar radiation factors specifically, slope orientation, ground composition and albedo. In...

275

Temperature compensated photovoltaic array  

DOE Patents [OSTI]

A temperature compensated photovoltaic module comprises a series of solar cells having a thermally activated switch connected in parallel with several of the cells. The photovoltaic module is adapted to charge conventional batteries having a temperature coefficient differing from the temperature coefficient of the module. The calibration temperatures of the switches are chosen whereby the colder the ambient temperature for the module, the more switches that are on and form a closed circuit to short the associated solar cells. By shorting some of the solar cells as the ambient temperature decreases, the battery being charged by the module is not excessively overcharged at lower temperatures. PV module is an integrated solution that is reliable and inexpensive. 2 figs.

Mosher, D.M.

1997-11-18T23:59:59.000Z

276

Temperature compensated photovoltaic array  

DOE Patents [OSTI]

A temperature compensated photovoltaic module (20) comprised of a series of solar cells (22) having a thermally activated switch (24) connected in parallel with several of the cells (22). The photovoltaic module (20) is adapted to charge conventional batteries having a temperature coefficient (TC) differing from the temperature coefficient (TC) of the module (20). The calibration temperatures of the switches (24) are chosen whereby the colder the ambient temperature for the module (20), the more switches that are on and form a closed circuit to short the associated solar cells (22). By shorting some of the solar cells (22) as the ambient temperature decreases, the battery being charged by the module (20) is not excessively overcharged at lower temperatures. PV module (20) is an integrated solution that is reliable and inexpensive.

Mosher, Dan Michael (Plano, TX)

1997-11-18T23:59:59.000Z

277

The bi-variate frequency distribution of two concurrent climatic variables: a study of temperature and dew point  

E-Print Network [OSTI]

for calculation of joint-event probabilities from the bi-variate normal distribution as follows: X and Y are random variables following a bi- variate normal distribution with zero means, unit variances and correlation coefficient p. Then: Pr [X & h, Y 2 k) = L... 1956-1960. Despite many useful applications, the calculation of frequencies or probabilities for specified events is somewhat limited to the class selections of the variables chosen for the study. Moreover, relative humidity is not a good indicator...

Zeitler, Jon William

1991-01-01T23:59:59.000Z

278

Piezoelectricity above the Curie temperature? Combining flexoelectricity and functional grading to enable high-temperature electromechanical coupling  

SciTech Connect (OSTI)

Most technologically relevant ferroelectrics typically lose piezoelectricity above the Curie temperature. This limits their use to relatively low temperatures. In this Letter, exploiting a combination of flexoelectricity and simple functional grading, we propose a strategy for high-temperature electromechanical coupling in a standard thin film configuration. We use continuum modeling to quantitatively demonstrate the possibility of achieving apparent piezoelectric materials with large and temperature-stable electromechanical coupling across a wide temperature range that extends significantly above the Curie temperature. With Barium and Strontium Titanate, as example materials, a significant electromechanical coupling that is potentially temperature-stable up to 900?°C is possible.

Mbarki, R. [Department of Mechanical Engineering, University of Houston, Houston, Texas 77204 (United States); Baccam, N. [Department of Mathematics, Southwestern University, Georgetown, Texas 78626 (United States); Dayal, Kaushik [Department of Civil and Environmental Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Sharma, P. [Department of Mechanical Engineering and Department of Physics, University of Houston, Houston, Texas 77204 (United States)

2014-03-24T23:59:59.000Z

279

Automatic temperature adjustment apparatus  

DOE Patents [OSTI]

An apparatus for increasing the efficiency of a conventional central space heating system is disclosed. The temperature of a fluid heating medium is adjusted based on a measurement of the external temperature, and a system parameter. The system parameter is periodically modified based on a closed loop process that monitors the operation of the heating system. This closed loop process provides a heating medium temperature value that is very near the optimum for energy efficiency.

Chaplin, James E. (66 Overlook Rd., Bloomingdale, NJ 07403)

1985-01-01T23:59:59.000Z

280

Temperature and RH Targets  

Broader source: Energy.gov [DOE]

Presented by Vishal O Mittal of the Florida Solar Energy Center at the High Temperature Membrane Working Group Meeting, San Francisco, September 14, 2006.

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Low temperature joining of ceramic composites  

DOE Patents [OSTI]

A method of joining similar or dissimilar ceramic and ceramic composite materials, such as SiC continuous fiber ceramic composites, at relatively low joining temperatures uses a solventless, three component bonding agent effective to promote mechanical bond toughness and elevated temperature strength to operating temperatures of approximately 1200 C. The bonding agent comprises a preceramic precursor, an aluminum bearing powder, such as aluminum alloy powder, and mixtures of aluminum metal or alloy powders with another powder, and boron powder in selected proportions. The bonding agent is disposed as an interlayer between similar or dissimilar ceramic or ceramic composite materials to be joined and is heated in ambient air or inert atmosphere to a temperature not exceeding about 1200 C to form a strong and tough bond joint between the materials. The bond joint produced is characterized by a composite joint microstructure having relatively soft, compliant aluminum bearing particulate regions dispersed in a ceramic matrix. 3 figs.

Barton, T.J.; Anderson, I.E.; Ijadi-Maghsoodi, S.; Nosrati, M.; Unal, O.

1999-07-13T23:59:59.000Z

282

Finite Temperature Gases of Fermionic Strings  

E-Print Network [OSTI]

We show that in the absence of a Ramond-Ramond sector both the type IIA and type IIB free string gases have a thermal instability due to low temperature tachyon modes. The gas of free IIA strings undergoes a thermal duality transition into a gas of free IIB strings at the self-dual temperature. The free heterotic string gas is a tachyon-free ensemble with gauge symmetry SO(16)$\\times$SO(16) in the presence of a timelike Wilson line background. It exhibits a holographic duality relation undergoing a self-dual phase transition with positive free energy and positive specific heat. The type IB open and closed string ensemble is related by thermal duality to the type I' string ensemble. We identify the order parameter for the Kosterlitz-Thouless phase transition from a low temperature gas of short open strings to a high temperature long string phase at or below T_C. Note Added (Sep 2005).

Shyamoli Chaudhuri

2005-09-12T23:59:59.000Z

283

Low temperature joining of ceramic composites  

DOE Patents [OSTI]

A method of joining similar or dissimilar ceramic and ceramic composite materials, such as SiC continuous fiber ceramic composites, at relatively low joining temperatures uses a solventless, three component bonding agent effective to promote mechanical bond toughness and elevated temperature strength to operating temperatures of approximately 1200 degrees C. The bonding agent comprises a preceramic precursor, an aluminum bearing powder, such as aluminum alloy powder, and mixtures of aluminum metal or alloy powders with another powder, and and boron powder in selected proportions. The bonding agent is disposed as an interlayer between similar or dissimilar ceramic or cermaic composite materials to be joined and is heated in ambient air or inert atmosphere to a temperature not exceeding about 1200 degrees C. to form a strong and tough bond joint between the materials. The bond joint produced is characterized by a composite joint microstructure having relatively soft, compliant aluminum bearing particulate regions dispersed in a ceramic matrix.

Barton, Thomas J. (Ames, IA); Anderson, Iver E. (Ames, IA); Ijadi-Maghsoodi, Sina (Ames, IA); Nosrati, Mohammad (Ames, IA); Unal, Ozer (Ames, IA)

2001-04-10T23:59:59.000Z

284

Low temperature joining of ceramic composites  

DOE Patents [OSTI]

A method of joining similar or dissimilar ceramic and ceramic composite materials, such as SiC continuous fiber ceramic composites, at relatively low joining temperatures uses a solventless, three component bonding agent effective to promote mechanical bond toughness and elevated temperature strength to operating temperatures of approximately 1200 degrees C. The bonding agent comprises a preceramic precursor, an aluminum bearing powder, such as aluminum alloy powder, and mixtures of aluminum metal or alloy powders with another powder, and boron powder in selected proportions. The bonding agent is disposed as an interlayer between similar or dissimilar ceramic or ceramic composite materials to be joined and is heated in ambient air or inert atmosphere to a temperature not exceeding about 1200 degrees C. to form a strong and tough bond joint between the materials. The bond joint produced is characterized by a composite joint microstructure having relatively soft, compliant aluminum bearing particulate regions dispersed in a ceramic matrix. 3 figs.

Barton, T.J.; Anderson, I.E.; Ijadi-Maghsoodi, S.; Nosrati, M.; Unal, O.

1999-01-12T23:59:59.000Z

285

Low temperature joining of ceramic composites  

DOE Patents [OSTI]

A method of joining similar or dissimilar ceramic and ceramic composite materials, such as SiC continuous fiber ceramic composites, at relatively low joining temperatures uses a solventless, three component bonding agent effective to promote mechanical bond toughness and elevated temperature strength to operating temperatures of approximately 1200 degrees C. The bonding agent comprises a preceramic precursor, an aluminum bearing powder, such as aluminum alloy powder, and mixtures of aluminum metal or alloy powders with another powder, and and boron powder in selected proportions. The bonding agent is disposed as an interlayer between similar or dissimilar ceramic or ceramic composite materials to be joined and is heated in ambient air or inert atmosphere to a temperature not exceeding about 1200 degrees C. to form a strong and tough bond joint between the materials. The bond joint produced is characterized by a composite joint microstructure having relatively soft, compliant aluminum bearing particulate regions dispersed in a ceramic matrix.

Barton, Thomas J. (Ames, IA); Anderson, Iver E. (Ames, IA); Ijadi-Maghsoodi, Sina (Ames, IA); Nosrati, Mohammad (Ames, IA); Unal, Ozer (Ames, IA)

1999-07-13T23:59:59.000Z

286

Low temperature joining of ceramic composites  

DOE Patents [OSTI]

A method of joining similar or dissimilar ceramic and ceramic composite materials, such as SiC continuous fiber ceramic composites, at relatively low joining temperatures uses a solventless, three component bonding agent effective to promote mechanical bond toughness and elevated temperature strength to operating temperatures of approximately 1200 degrees C. The bonding agent comprises a preceramic precursor, an aluminum bearing powder, such as aluminum alloy powder, and mixtures of aluminum metal or alloy powders with another powder, and and boron powder in selected proportions. The bonding agent is disposed as an interlayer between similar or dissimilar ceramic or cermaic composite materials to be joined and is heated in ambient air or inert atmosphere to a temperature not exceeding about 1200 degrees C. to form a strong and tough bond joint between the materials. The bond joint produced is characterized by a composite joint microstructure having relatively soft, compliant aluminum bearing particulate regions dispersed in a ceramic matrix.

Barton, Thomas J. (Ames, IA); Anderson, Iver E. (Ames, IA); Ijadi-Maghsoodi, Sina (Ames, IA); Nosrati, Mohammad (Ames, IA); Unal, Ozer (Ames, IA)

1999-01-12T23:59:59.000Z

287

Climate and weather events can impact human health in many ways. Climate trends, such as warming temperatures and changes in precipitation patterns, can affect the distribution of waterborne and vector-borne  

E-Print Network [OSTI]

and mortality. Providing access to relevant climate information is essential to understanding how climate trends. · Using relative humidity and wind speed data to study the relationship between fine particulate air pollution and daily mortality counts. NOAA's National Climatic Data Center Sectoral Engagement Fact Sheet

288

Fiber optic temperature sensor  

SciTech Connect (OSTI)

Our fiber optic temperature measurement sensor and system is a major improvement over methods currently in use in most industrial processes, and it delivers all of the attributes required simplicity, accuracy, and cost efficiency-to help improve all of these processes. Because temperature is a basic physical attribute of nearly every industrial and commercial process, our system can eventually result in significant improvements in nearly every industrial and commercial process. Many finished goods, and the materials that go into them, are critically dependent on the temperature. The better the temperature measurement, the better quality the goods will be and the more economically they can be produced. The production and transmission of energy requires the monitoring of temperature in motors, circuit breakers, power generating plants, and transmission line equipment. The more reliable and robust the methods for measuring these temperature, the more available, stable, and affordable the supply of energy will become. The world is increasingly realizing the threats to health and safety of toxic or otherwise undesirable by products of the industrial economy in the environment. Cleanup of such contamination often depends on techniques that require the constant monitoring of temperature in extremely hazardous environments, which can damage most conventional temperature sensors and which are dangerous for operating personnel. Our system makes such monitoring safer and more economical.

Rabold, D.

1995-12-01T23:59:59.000Z

289

High temperature probe  

DOE Patents [OSTI]

A high temperature probe for sampling, for example, smokestack fumes, and is able to withstand temperatures of 3000.degree. F. The probe is constructed so as to prevent leakage via the seal by placing the seal inside the water jacket whereby the seal is not exposed to high temperature, which destroys the seal. The sample inlet of the probe is also provided with cooling fins about the area of the seal to provide additional cooling to prevent the seal from being destroyed. Also, a heated jacket is provided for maintaining the temperature of the gas being tested as it passes through the probe. The probe includes pressure sensing means for determining the flow velocity of an efficient being sampled. In addition, thermocouples are located in various places on the probe to monitor the temperature of the gas passing there through.

Swan, Raymond A. (Fremont, CA)

1994-01-01T23:59:59.000Z

290

University of Illinois Temperature Sensors  

SciTech Connect (OSTI)

This document summarizes background information and presents results related to temperature measurements in the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) University of Illinois Project 29609 irradiation. The objective of this test was to assess the radiation performance of ferritic alloys for advanced reactor applications. The FeCr-based alloy system is considered the lead alloy system for a variety of advanced reactor components and applications. Irradiations of FeCr alloy samples were performed using the Hydraulic Shuttle Irradiation System (HSIS) in the B-7 position and in a static capsule in the A-11 position of the ATR.

K. L. Davis; D. L. Knudson; J. L. Rempe; B. M. Chase

2014-09-01T23:59:59.000Z

291

Analysis of Energy, Environmental and Life Cycle Cost Reduction Potential of Ground Source Heat Pump (GSHP) in Hot and Humid Climate  

SciTech Connect (OSTI)

It has been widely recognized that the energy saving benefits of GSHP systems are best realized in the northern and central regions where heating needs are dominant or both heating and cooling loads are comparable. For hot and humid climate such as in the states of FL, LA, TX, southern AL, MS, GA, NC and SC, buildings have much larger cooling needs than heating needs. The Hybrid GSHP (HGSHP) systems therefore have been developed and installed in some locations of those states, which use additional heat sinks (such as cooling tower, domestic water heating systems) to reject excess heat. Despite the development of HGSHP the comprehensive analysis of their benefits and barriers for wide application has been limited and often yields non-conclusive results. In general, GSHP/HGSHP systems often have higher initial costs than conventional systems making short-term economics unattractive. Addressing these technical and financial barriers call for additional evaluation of innovative utility programs, incentives and delivery approaches. From scientific and technical point of view, the potential for wide applications of GSHP especially HGSHP in hot and humid climate is significant, especially towards building zero energy homes where the combined energy efficient GSHP and abundant solar energy production in hot climate can be an optimal solution. To address these challenges, this report presents gathering and analyzing data on the costs and benefits of GSHP/HGSHP systems utilized in southern states using a representative sample of building applications. The report outlines the detailed analysis to conclude that the application of GSHP in Florida (and hot and humid climate in general) shows a good potential.

Yong X. Tao; Yimin Zhu

2012-04-26T23:59:59.000Z

292

Relational Database SQL: Querying the Relational DB  

E-Print Network [OSTI]

: auto-completion and command history Weigang Qiu Relational Database & SQL #12;Relational Database SQLRelational Database SQL: Querying the Relational DB Workshop: the "genome" Database Relational Database & SQL Weigang Qiu Department of Biological Sciences Hunter College BIOL 425 Computational

Qiu, Weigang

293

High Temperature Capacitor Development  

SciTech Connect (OSTI)

The absence of high-temperature electronics is an obstacle to the development of untapped energy resources (deep oil, gas and geothermal). US natural gas consumption is projected to grow from 22 trillion cubic feet per year (tcf) in 1999 to 34 tcf in 2020. Cumulatively this is 607 tcf of consumption by 2020, while recoverable reserves using current technology are 177 tcf. A significant portion of this shortfall may be met by tapping deep gas reservoirs. Tapping these reservoirs represents a significant technical challenge. At these depths, temperatures and pressures are very high and may require penetrating very hard rock. Logistics of supporting 6.1 km (20,000 ft) drill strings and the drilling processes are complex and expensive. At these depths up to 50% of the total drilling cost may be in the last 10% of the well depth. Thus, as wells go deeper it is increasingly important that drillers are able to monitor conditions down-hole such as temperature, pressure, heading, etc. Commercial off-the-shelf electronics are not specified to meet these operating conditions. This is due to problems associated with all aspects of the electronics including the resistors and capacitors. With respect to capacitors, increasing temperature often significantly changes capacitance because of the strong temperature dependence of the dielectric constant. Higher temperatures also affect the equivalent series resistance (ESR). High-temperature capacitors usually have low capacitance values because of these dielectric effects and because packages are kept small to prevent mechanical breakage caused by thermal stresses. Electrolytic capacitors do not operate at temperatures above 150oC due to dielectric breakdown. The development of high-temperature capacitors to be used in a high-pressure high-temperature (HPHT) drilling environment was investigated. These capacitors were based on a previously developed high-voltage hybridized capacitor developed at Giner, Inc. in conjunction with a unique high-temperature electrolyte developed during the course of the program. During this program the feasibility of operating a high voltage hybridized capacitor at 230oC was demonstrated. Capacitor specifications were established in conjunction with potential capacitor users. A method to allow for capacitor operation at both ambient and elevated temperatures was demonstrated. The program was terminated prior to moving into Phase II due to a lack of cost-sharing funds.

John Kosek

2009-06-30T23:59:59.000Z

294

Novel room temperature ferromagnetic semiconductors  

SciTech Connect (OSTI)

Today's information world, bits of data are processed by semiconductor chips, and stored in the magnetic disk drives. But tomorrow's information technology may see magnetism (spin) and semiconductivity (charge) combined in one 'spintronic' device that exploits both charge and 'spin' to carry data (the best of two worlds). Spintronic devices such as spin valve transistors, spin light emitting diodes, non-volatile memory, logic devices, optical isolators and ultra-fast optical switches are some of the areas of interest for introducing the ferromagnetic properties at room temperature in a semiconductor to make it multifunctional. The potential advantages of such spintronic devices will be higher speed, greater efficiency, and better stability at a reduced power consumption. This Thesis contains two main topics: In-depth understanding of magnetism in Mn doped ZnO, and our search and identification of at least six new above room temperature ferromagnetic semiconductors. Both complex doped ZnO based new materials, as well as a number of nonoxides like phosphides, and sulfides suitably doped with Mn or Cu are shown to give rise to ferromagnetism above room temperature. Some of the highlights of this work are discovery of room temperature ferromagnetism in: (1) ZnO:Mn (paper in Nature Materials, Oct issue, 2003); (2) ZnO doped with Cu (containing no magnetic elements in it); (3) GaP doped with Cu (again containing no magnetic elements in it); (4) Enhancement of Magnetization by Cu co-doping in ZnO:Mn; (5) CdS doped with Mn, and a few others not reported in this thesis. We discuss in detail the first observation of ferromagnetism above room temperature in the form of powder, bulk pellets, in 2-3 mu-m thick transparent pulsed laser deposited films of the Mn (<4 at. percent) doped ZnO. High-resolution transmission electron microscopy (HRTEM) and electron energy loss spectroscopy (EELS) spectra recorded from 2 to 200nm areas showed homogeneous distribution of Mn substituting for Zn a 2+ state in the ZnO lattice. Ferromagnetic Resonance (FMR) technique is used to confirm the existence of ferromagnetic ordering at temperatures as high as 425K. The ab initio calculations were found to be consistent with the observation of ferromagnetism arising from fully polarized Mn 2+ state. The key to observed room temperature ferromagnetism in this system is the low temperature processing, which prevents formation of clusters, secondary phases and the host ZnO from becoming n-type. The electronic structure of the same Mn doped ZnO thin films studied using XAS, XES and RIXS, revealed a strong hybridization between Mn 3d and O 2p states, which is an important characteristic of a Dilute magnetic Semiconductor (DMS). It is shown that the various processing conditions like sintering temperature, dopant concentration and the properties of precursors used for making of DMS have a great influence on the final properties. Use of various experimental techniques to verify the physical properties, and to understand the mechanism involved to give rise to ferromagnetism is presented. Methods to improve the magnetic moment in Mn doped ZnO are also described. New promising DMS materials (such as Cu doped ZnO are explored). The demonstrated new capability to fabricate powder, pellets, and thin films of room temperature ferromagnetic semiconductors thus makes possible the realization of a wide range of complex elements for a variety of new multifunctional phenomena related to Spintronic devices as well as magneto-optic components.

Gupta, Amita

2004-11-01T23:59:59.000Z

295

High-Temperature Superconductivity  

ScienceCinema (OSTI)

Like astronomers tweaking images to gain a more detailed glimpse of distant stars, physicists at Brookhaven National Laboratory have found ways to sharpen images of the energy spectra in high-temperature superconductors ? materials that carry electrical c

Peter Johnson

2010-01-08T23:59:59.000Z

296

Elevated temperature crack propagation  

SciTech Connect (OSTI)

This paper is a summary of two NASA contracts on high temperature fatigue crack propagation in metals. The first evaluated the ability of fairly simple nonlinear fracture parameters to correlate crack propagation. Hastelloy-X specimens were tested under isothermal and thermomechanical cycling at temperatures up to 980 degrees C (1800 degrees F). The most successful correlating parameter was the crack tip opening displacement derived from the J-integral. The second evaluated the ability of several path-independent integrals to correlate crack propagation behavior. Inconel 718 specimens were tested under isothermal, thermomechanical, temperature gradient, and creep conditions at temperatures up to 650 degrees C (1200 degrees F). The integrals formulated by Blackburn and by Kishimoto correlated the data reasonably well under all test conditions.

Orange, T.W.

1994-02-01T23:59:59.000Z

297

Penrose Well Temperatures  

SciTech Connect (OSTI)

Penrose Well Temperatures Geothermal waters have been encountered in several wells near Penrose in Fremont County, Colorado. Most of the wells were drilled for oil and gas exploration and, in a few cases, production. This ESRI point shapefile utilizes data from 95 wells in and around the Penrose area provided by the Colorado Oil and Gas Conservation Commission (COGCC) database at http://cogcc.state.co.us/ . Temperature data from the database were used to calculate a temperature gradient for each well. This information was then used to estimate temperatures at various depths. Projection: UTM Zone 13 NAD27 Extent: West -105.224871 East -105.027633 North 38.486269 South 38.259507 Originators: Colorado Oil and Gas Conservation Commission (COGCC) Karen Christopherson

Christopherson, Karen

2013-03-15T23:59:59.000Z

298

High temperature pressure gauge  

DOE Patents [OSTI]

A high temperature pressure gauge comprising a pressure gauge positioned in fluid communication with one end of a conduit which has a diaphragm mounted in its other end. The conduit is filled with a low melting metal alloy above the diaphragm for a portion of its length with a high temperature fluid being positioned in the remaining length of the conduit and in the pressure gauge.

Echtler, J. Paul (Pittsburgh, PA); Scandrol, Roy O. (Library, PA)

1981-01-01T23:59:59.000Z

299

Heat Transfer Reduction Across the Walls of Refrigerated Van Trailers by the Application of Phase Change Material  

E-Print Network [OSTI]

is done within a temperature range, which accounts for different indoor and outdoor conditions, such as, temperature, relative humidity, and wind speed [18]. The setup was located in the University of Kansas campus at Lawrence, Kansas. Lawrence... with anemometer, rain fall measurement device, and relative humidity measurement device ........................................................... 33 Figure 23. Solar spectral pyranometer...

Ahmed, Mashud

2009-03-13T23:59:59.000Z

300

Effect of temperature on performance of {sup 3}He filled neutron proportional counters  

SciTech Connect (OSTI)

Neutron detectors used for cosmic neutron monitoring and various other applications are mounted in hostile environment. It is essential for detectors to sustain extreme climatic conditions, such as extreme temperature and humidity. Effort is made to evaluate the performance of detectors in extreme temperature in terms of pulse height distribution and avalanche formation. Neutron detectors filled with {sup 3}He incorporate an additive gas with quantity optimized for a particular application. Measurements are performed on neutron detectors filled with {sup 3}He and stopping gases Kr and CF{sub 4}. Detector performance for these fill gas combinations in terms of pulse height distribution is evaluated. Gas gain and Diethorn gas constants measured and analyzed for the microscopic effect on pulse formation. Results from these investigations are presented.

Desai, Shraddha S., E-mail: ssdesai@barc.gov.in [Solid State Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India)

2014-04-24T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Winchester/Camberley Homes New Construction Test House Design, Construction, and Short-Term Testing in a Mixed-Humid Climate  

SciTech Connect (OSTI)

The NAHB Research Center partnered with production builder Winchester/Camberley Homes to build a DOE Building America New Construction Test House (NCTH). This single family, detached house, located in the mixed-humid climate zone of Silver Spring, MD, was completed in June 2011. The primary goal for this house was to improve energy efficiency by 30% over the Building America B10 benchmark by developing and implementing an optimized energy solutions package design that could be cost effectively and reliably constructed on a production basis using quality management practices. The intent of this report is to outline the features of this house, discuss the implementation of the energy efficient design, and report on short-term testing results. During the interactive design process of this project, numerous iterations of the framing, air sealing, insulation, and space conditioning systems were evaluated for energy performance, cost, and practical implementation. The final design featured numerous advanced framing techniques, high levels of insulation, and the HVAC system entirely within conditioned space. Short-term testing confirmed a very tight thermal envelope and efficient and effective heating and cooling. In addition, relevant heating, cooling, humidity, energy, and wall cavity moisture data will be collected and presented in a future long-term report.

Mallav, D.; Wiehagen, J.; Wood, A.

2012-10-01T23:59:59.000Z

302

Temperature initiated passive cooling system  

DOE Patents [OSTI]

A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature.

Forsberg, Charles W. (Oak Ridge, TN)

1994-01-01T23:59:59.000Z

303

Temperature initiated passive cooling system  

DOE Patents [OSTI]

A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature. 1 fig.

Forsberg, C.W.

1994-11-01T23:59:59.000Z

304

High temperature thermometric phosphors  

DOE Patents [OSTI]

A high temperature phosphor consists essentially of a material having the general formula LuPO{sub 4}:Dy{sub x},Eu{sub y} wherein: 0.1 wt % {<=} x {<=} 20 wt % and 0.1 wt % {<=} y {<=} 20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopant. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions. 2 figs.

Allison, S.W.; Cates, M.R.; Boatner, L.A.; Gillies, G.T.

1999-03-23T23:59:59.000Z

305

High temperature thermometric phosphors  

DOE Patents [OSTI]

A high temperature phosphor consists essentially of a material having the general formula LuPO.sub.4 :Dy.sub.(x),Eu.sub.y) wherein: 0.1 wt %.ltoreq.x.ltoreq.20 wt % and 0.1 wt %.ltoreq.y.ltoreq.20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopent. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions.

Allison, Stephen W. (Knoxville, TN); Cates, Michael R. (Oak Ridge, TN); Boatner, Lynn A. (Oak Ridge, TN); Gillies, George T. (Earlysville, VA)

1999-03-23T23:59:59.000Z

306

Temperature Data Evaluation  

SciTech Connect (OSTI)

Groundwater temperature is sensitive to the competing processes of heat flow from below the advective transport of heat by groundwater flow. Because groundwater temperature is sensitive to conductive and advective processes, groundwater temperature may be utilized as a tracer to further constrain the uncertainty of predictions of advective radionuclide transport models constructed for the Nevada Test Site (NTS). Since heat transport, geochemical, and hydrologic models for a given area must all be consistent, uncertainty can be reduced by devaluing the weight of those models that do not match estimated heat flow. The objective of this study was to identify the quantity and quality of available heat flow data at the NTS. One-hundred-forty-five temperature logs from 63 boreholes were examined. Thirteen were found to have temperature profiles suitable for the determination of heat flow values from one or more intervals within the boreholes. If sufficient spatially distributed heat flow values are obtained, a heat transport model coupled to a hydrologic model may be used to reduce the uncertainty of a nonisothermal hydrologic model of the NTS.

Gillespie, David

2003-03-01T23:59:59.000Z

307

High temperature ceramic composition for hydrogen retention  

DOE Patents [OSTI]

A ceramic coating for H retention in fuel elements is described. The coating has relatively low thermal neutron cross section, is not readily reduced by H at 1500 deg F, is adherent to the fuel element base metal, and is stable at reactor operating temperatures. (JRD)

Webb, R.W.

1974-01-01T23:59:59.000Z

308

High-temperature Pump Monitoring - High-temperature ESP Monitoring...  

Broader source: Energy.gov (indexed) [DOE]

7 4.4.4 High-temperature Pump Monitoring - High-temperature ESP Monitoring Presentation Number: 018 Investigator: Dhruva, Brindesh (Schlumberger Technology Corp.) Objectives: To...

309

Active radiometer for self-calibrated furnace temperature measurements  

DOE Patents [OSTI]

Radiometer with a probe beam superimposed on its field-of-view for furnace temperature measurements. The radiometer includes a heterodyne millimeter/submillimeter-wave receiver including a millimeter/submillimeter-wave source for probing. The receiver is adapted to receive radiation from a surface whose temperature is to be measured. The radiation includes a surface emission portion and a surface reflection portion which includes the probe beam energy reflected from the surface. The surface emission portion is related to the surface temperature and the surface reflection portion is related to the emissivity of the surface. The simultaneous measurement of surface emissivity serves as a real time calibration of the temperature measurement.

Woskov, Paul P. (Bedford, MA); Cohn, Daniel R. (Chestnut Hill, MA); Titus, Charles H. (Newtown Square, PA); Wittle, J. Kenneth (Chester Springs, PA); Surma, Jeffrey E. (Kennewick, WA)

1996-01-01T23:59:59.000Z

310

Fluorescent temperature sensor  

DOE Patents [OSTI]

The present invention is a fluorescent temperature sensor or optical thermometer. The sensor includes a solution of 1,3-bis(1-pyrenyl)propane within a 1-butyl-1-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ionic liquid solvent. The 1,3-bis(1-pyrenyl)propane remains unassociated when in the ground state while in solution. When subjected to UV light, an excited state is produced that exists in equilibrium with an excimer. The position of the equilibrium between the two excited states is temperature dependent.

Baker, Gary A [Los Alamos, NM; Baker, Sheila N [Los Alamos, NM; McCleskey, T Mark [Los Alamos, NM

2009-03-03T23:59:59.000Z

311

Temperature differential detection device  

DOE Patents [OSTI]

A temperature differential detection device for detecting the temperature differential between predetermined portions of a container wall is disclosed as comprising a Wheatstone bridge circuit for detecting resistance imbalance with a first circuit branch having a first elongated wire element mounted in thermal contact with a predetermined portion of the container wall, a second circuit branch having a second elongated wire element mounted in thermal contact with a second predetermined portion of a container wall with the wire elements having a predetermined temperature-resistant coefficient, an indicator interconnected between the first and second branches remote from the container wall for detecting and indicating resistance imbalance between the first and second wire elements, and connector leads for electrically connecting the wire elements to the remote indicator in order to maintain the respective resistance value relationship between the first and second wire elements. The indicator is calibrated to indicate the detected resistance imbalance in terms of a temperature differential between the first and second wall portions. 2 figs.

Girling, P.M.

1986-04-22T23:59:59.000Z

312

Low Temperature Performance Characterization  

Broader source: Energy.gov (indexed) [DOE]

0.0036 0.0038 0.004 0.0042 Inverse Temperature, 1K Gen2 Electrodes and 1.2M LiPF6 in EC:EMC (3:7 ww) (BID 1935), 4.1V, 3 Sep. Gen2 Electrodes and 1.2M LiPF6 in EC:EMC (3:7 ww)...

313

Heat transfer in theory of relativity  

E-Print Network [OSTI]

The traditional Fourier equation just allows us to study the evolution of temperature in an "undeformable" bar. The search for its relativistic variant is a task which is expected to fail because in relativity there are no undeformable bars. Rigid bodies, in the sense of "as rigid as possible", are deformables. In this work we show how to write in relativity the system of equations necessary to study simultaneously deformation and temperature evolution along a rigid deformable bar. The solutions of the two simultaneous equations is discussed assuming convenient constitutive relations for the material. An application is presented.

A. Brotas; J. C. Fernandes

2006-04-27T23:59:59.000Z

314

Localized temperature stability of low temperature cofired ceramics  

DOE Patents [OSTI]

The present invention is directed to low temperature cofired ceramic modules having localized temperature stability by incorporating temperature coefficient of resonant frequency compensating materials locally into a multilayer LTCC module. Chemical interactions can be minimized and physical compatibility between the compensating materials and the host LTCC dielectrics can be achieved. The invention enables embedded resonators with nearly temperature-independent resonance frequency.

Dai, Steven Xunhu

2013-11-26T23:59:59.000Z

315

Evaluating Energy Performance and Improvement Potential of China Office Buildings in the Hot Humid Climate Against U.S. Reference Buildings: Preprint  

SciTech Connect (OSTI)

This study compares the building code standards for office buildings in hot humid climates of China and the USA. A benchmark office building model is developed for Guangzhou, China that meets China's minimum national and regional building codes with incorporation of common design and construction practices for the area. The Guangzhou office benchmark model is compared to the ASHRAE standard based US model for Houston, Texas which has similar climate conditions. The research further uses a building energy optimization tool to optimize the Chinese benchmark with existing US products to identify the primary areas for potential energy savings. The most significant energy-saving options are then presented as recommendations for potential improvements to current China building codes.

Herrman, L.; Deru, M.; Zhai, J.

2010-08-01T23:59:59.000Z

316

Building America Best Practices Series: Volume 4; Builders and Buyers Handbook for Improving New Home Efficiency, Comfort, and Durability in the Mixed-Humid Climate Climate Regions  

SciTech Connect (OSTI)

This best practices guide is part of a series produced by Building America. The guide book is a resource to help builders large and small build high-quality, energy-efficient homes that achieve 30% energy savings in space conditioning and water heating in the mixed-humid climate region. The savings are in comparison with the 1993 Model Energy Code. The guide contains chapters for every member of the builder?s team?from the manager to the site planner to the designers, site supervisors, the trades, and marketers. There is also a chapter for homeowners on how to use the book to provide help in selecting a new home or builder.

Baechler, M. C.; Love, P. M.

2005-09-01T23:59:59.000Z

317

How and why electrostatic charge of combustible nanoparticles can radically change the mechanism and rate of their oxidation in humid atmosphere  

E-Print Network [OSTI]

Electrostatically charged aerosol nanoparticles strongly attract surrounding polar gas molecules due to a charge-dipole interaction. In humid air, the substantial electrostatic attraction and acceleration of surrounding water vapour molecules towards charged combustible nanoparticles cause intense electrostatic hydration and preferential oxidation of these nanoparticles by accelerated water vapor molecules rather than non-polar oxygen molecules. In particular, electrostatic acceleration, acquired by surrounding water vapour molecules at a distance of their mean free path from the minimally charged iron metal nanoparticle can increase an oxidative activity of these polar molecules with respect to the nanoparticle by a factor of one million. Intense electrostatic hydration of charged metal nanoparticles converts the nanoparticle's oxide based shells into the hydroxide based electrolyte shells, transforming these nanoparticles into metal/air core-shell nanobatteries, periodically short-circuited by intra-particl...

Meshcheryakov, Oleg

2010-01-01T23:59:59.000Z

318

Building America Residential System Research Results: Achieving 30% Whole House Energy Savings Level in Mixed-Humid Climates; January 2006 - December 2006  

SciTech Connect (OSTI)

The Building America program conducts the system research required to reduce risks associated with the design and construction of homes that use an average of 30% to 90% less total energy for all residential energy uses than the Building America Research Benchmark, including research on homes that will use zero net energy on annual basis. To measure the program's progress, annual research milestones have been established for five major climate regions in the United States. The system research activities required to reach each milestone take from 3 to 5 years to complete and include research in individual test houses, studies in pre-production prototypes, and research studies with lead builders that provide early examples that the specified energy savings level can be successfully achieved on a production basis. This report summarizes research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in the Mixed-Humid Climate Region on a cost-neutral basis.

Building America Industrialized Housing Partnership (BAIHP); Building Industry Research Alliance (BIRA); Building Science Consortium (BSC); Consortium for Advanced Residential Buildings (CARB); Davis Energy Group (DEG); IBACOS; National Association of Home Builders Research Center (NAHBRC); National Renewable Energy Laboratory (NREL)

2006-12-01T23:59:59.000Z

319

Wall Design Redundancy for Improving the Moisture Performance of Building Cladding Systems in Hot-Humid Climates  

E-Print Network [OSTI]

had leaks that introduced enough water to rot the wood fiaming supporting their cladding. Water-related problems with EIFS in over 300 homes in the Wilmington, North Carolina area were reported by the NAHB Research Center in 1996, and before... the recommendations included in a report entitled "Moisture Assessment Guidelines," by the NAHB Research Center (Appendix A, 1996) and modified by the author (Graham 1997), was used on the home inspections in Texas. In these inspections, areas known to be leak...

Graham, C. W.

2000-01-01T23:59:59.000Z

320

Conformal Invariance of Black Hole Temperature  

E-Print Network [OSTI]

It is shown that the surface gravity and temperature of a stationary black hole are invariant under conformal transformations of the metric that are the identity at infinity. More precisely, we find a conformal invariant definition of the surface gravity of a conformal Killing horizon that agrees with the usual definition(s) for a true Killing horizon and is proportional to the temperature as defined by Hawking radiation. This result is reconciled with the intimate relation between the trace anomaly and the Hawking effect, despite the {\\it non}invariance of the trace anomaly under conformal transformations.

Ted Jacobson; Gungwon Kang

1993-07-06T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Determination of the Relative Amount of Fluorine in Uranium Oxyfluoride Particles using Secondary Ion Mass Spectrometry and Optical Spectroscopy  

SciTech Connect (OSTI)

Both nuclear forensics and environmental sampling depend upon laboratory analysis of nuclear material that has often been exposed to the environment after it has been produced. It is therefore important to understand how those environmental conditions might have changed the chemical composition of the material over time, particularly for chemically sensitive compounds. In the specific case of uranium enrichment facilities, uranium-bearing particles stem from small releases of uranium hexafluoride, a highly reactive gas that hydrolyzes upon contact with moisture from the air to form uranium oxyfluoride (UO{sub 2}F{sub 2}) particles. The uranium isotopic composition of those particles is used by the International Atomic Energy Agency (IAEA) to verify whether a facility is compliant with its declarations. The present study, however, aims to demonstrate how knowledge of time-dependent changes in chemical composition, particle morphology and molecular structure can contribute to an even more reliable interpretation of the analytical results. We prepared a set of uranium oxyfluoride particles at the Institute for Reference Materials and Measurements (IRMM, European Commission, Belgium) and followed changes in their composition, morphology and structure with time to see if we could use these properties to place boundaries on the particle exposure time in the environment. Because the rate of change is affected by exposure to UV-light, humidity levels and elevated temperatures, the samples were subjected to varying conditions of those three parameters. The NanoSIMS at LLNL was found to be the optimal tool to measure the relative amount of fluorine in individual uranium oxyfluoride particles. At PNNL, cryogenic laser-induced time-resolved U(VI) fluorescence microspectroscopy (CLIFS) was used to monitor changes in the molecular structure.

Kips, R; Kristo, M J; Hutcheon, I D; Amonette, J; Wang, Z; Johnson, T; Gerlach, D; Olsen, K B

2009-05-29T23:59:59.000Z

322

Elevated-Temperature Tribology of Metallic Materials  

SciTech Connect (OSTI)

The wear of metals and alloys takes place in many forms, and the type of wear that dominates in each instance is influenced by the mechanics of contact, material properties, the interfacial temperature, and the surrounding environment. The control of elevated-temperature friction and wear is important for applications like internal combustion engines, aerospace propulsion systems, and metalworking equipment. The progression of interacting, often synergistic processes produces surface deformation, subsurface damage accumulation, the formation of tribolayers, and the creation of free particles. Reaction products, particularly oxides, play a primary role in debris formation and microstructural evolution. Chemical reactions are known to be influenced by the energetic state of the exposed surfaces, and that surface energy is in turn affected by localized deformation and fracture. At relatively low temperatures, work-hardening can occur beneath tribo-contacts, but exposure to high temperatures can modify the resultant defect density and grain structure to affect the mechanisms of re-oxidation. As research by others has shown, the rate of wear at elevated temperatures can either be enhanced or reduced, depending on contact conditions and nature of oxide layer formation. Furthermore, the thermodynamic driving force for certain chemical reactions is moderated by kinetics and microstructure. The role of deformation, oxidation, and tribo-corrosion in the elevated temperature tribology of metallic alloys will be exemplified by three examples involving sliding wear, single-point abrasion, and repetitive impact plus slip.

Blau, Peter Julian [ORNL

2010-01-01T23:59:59.000Z

323

High Temperature Membrane Working Group  

Broader source: Energy.gov [DOE]

This presentation provides an overview of the High Temperature Membrane Working Group Meeting in May 2007.

324

Engine Cylinder Temperature Control  

DOE Patents [OSTI]

A method and apparatus for controlling a temperature in a combustion cylinder in an internal combustion engine. The cylinder is fluidly connected to an intake manifold and an exhaust manifold. The method and apparatus includes increasing a back pressure associated with the exhaust manifold to a level sufficient to maintain a desired quantity of residual exhaust gas in the cylinder, and varying operation of an intake valve located between the intake manifold and the cylinder to an open duration sufficient to maintain a desired quantity of fresh air from the intake manifold to the cylinder, wherein controlling the quantities of residual exhaust gas and fresh air are performed to maintain the temperature in the cylinder at a desired level.

Kilkenny, Jonathan Patrick (Peoria, IL); Duffy, Kevin Patrick (Metamora, IL)

2005-09-27T23:59:59.000Z

325

Manufacturing High Temperature Systems  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department of Energy Low-TemperatureEnergyAll ManufacturingFoodOctoberto DOE

326

Intermediate Temperature Solid Oxide Fuel Cell Development  

SciTech Connect (OSTI)

Solid oxide fuel cells (SOFCs) are high efficiency energy conversion devices. Present materials set, using yttria stabilized zirconia (YSZ) electrolyte, limit the cell operating temperatures to 800 C or higher. It has become increasingly evident however that lowering the operating temperature would provide a more expeditious route to commercialization. The advantages of intermediate temperature (600 to 800 C) operation are related to both economic and materials issues. Lower operating temperature allows the use of low cost materials for the balance of plant and limits degradation arising from materials interactions. When the SOFC operating temperature is in the range of 600 to 700 C, it is also possible to partially reform hydrocarbon fuels within the stack providing additional system cost savings by reducing the air preheat heat-exchanger and blower size. The promise of Sr and Mg doped lanthanum gallate (LSGM) electrolyte materials, based on their high ionic conductivity and oxygen transference number at the intermediate temperature is well recognized. The focus of the present project was two-fold: (a) Identify a cell fabrication technique to achieve the benefits of lanthanum gallate material, and (b) Investigate alternative cathode materials that demonstrate low cathode polarization losses at the intermediate temperature. A porous matrix supported, thin film cell configuration was fabricated. The electrode material precursor was infiltrated into the porous matrix and the counter electrode was screen printed. Both anode and cathode infiltration produced high performance cells. Comparison of the two approaches showed that an infiltrated cathode cells may have advantages in high fuel utilization operations. Two new cathode materials were evaluated. Northwestern University investigated LSGM-ceria composite cathode while Caltech evaluated Ba-Sr-Co-Fe (BSCF) based pervoskite cathode. Both cathode materials showed lower polarization losses at temperatures as low as 600 C than conventional manganite or cobaltite cathodes.

S. Elangovan; Scott Barnett; Sossina Haile

2008-06-30T23:59:59.000Z

327

Introducing an Online Cooling Tower Performance Analysis Tool  

E-Print Network [OSTI]

and variable nature of all of the factors that can influence performance; fan speed, wind speed, sump temperature, heat load, ambient temperature, relative humidity, etc. This can be overwhelming for a regular operator resulting in many cooling towers being set...

Muller, M.R.; Muller, M.B.; Rao, P.

2012-01-01T23:59:59.000Z

328

Low Temperature Air Bake of Stainless Steel for Very Low  

E-Print Network [OSTI]

that gives very hot water with detergent. #12;4. The method of using a relatively low temperature air bake of the requirements for high quality forged blanks for flanges. After machining using a water based lubricantLow Temperature Air Bake of Stainless Steel for Very Low Outgassing Rates Surface Conditioning

329

NGNP/HTE full-power operation at reduced high-temperature heat exchanger temperatures.  

SciTech Connect (OSTI)

Operation of the Next Generation Nuclear Plant (NGNP) with reduced reactor outlet temperature at full power was investigated for the High Temperature Electrolysis (HTE) hydrogen-production application. The foremost challenge for operation at design temperature is achieving an acceptably long service life for heat exchangers. In both the Intermediate Heat Exchanger (IHX) and the Process Heat Exchanger (PHX) (referred to collectively as high temperature heat exchangers) a pressure differential of several MPa exists with temperatures at or above 850 C. Thermal creep of the heat exchanger channel wall may severely limit heat exchanger life depending on the alloy selected. This report investigates plant performance with IHX temperatures reduced by lowering reactor outlet temperature. The objective is to lower the temperature in heat transfer channels to the point where existing materials can meet the 40 year lifetime needed for this component. A conservative estimate for this temperature is believed to be about 700 C. The reactor outlet temperature was reduced from 850 C to 700 C while maintaining reactor power at 600 MWt and high pressure compressor outlet at 7 MPa. We included a previously reported design option for reducing temperature at the PHX. Heat exchanger lengths were adjusted to reflect the change in performance resulting from coolant property changes and from resizing related to operating-point change. Turbomachine parameters were also optimized for the new operating condition. An integrated optimization of the complete system including heat transfer equipment was not performed. It is estimated, however, that by performing a pinch analysis the combined plant efficiency can be increased from 35.5 percent obtained in this report to a value between 38.5 and 40.1 percent. Then after normalizing for a more than three percent decrease in commodities inventory compared to the reference plant, the commodities-normalized efficiency lies between 40.0 and 41.3. This compares with a value of 43.9 for the reference plant. This latter plant has a reactor outlet temperature of 850 C and the two high temperature heat exchangers. The reduction in reactor outlet temperature from 850 C to 700 C reduces the tritium permeability rate in the IHX metal by a factor of three and thermal creep by five orders of magnitude. The design option for reducing PHX temperature from 800 C to 200 C reduces the permeability there by three orders of magnitude. In that design option this heat exchanger is the single 'choke-point' for tritium migration from the nuclear to the chemical plant.

VIlim, R.; Nuclear Engineering Division

2009-03-12T23:59:59.000Z

330

Holographic conductivity of zero temperature superconductors  

E-Print Network [OSTI]

Using the recently found by G. Horowitz and M. Roberts (arXiv:0908.3677) numerical model of the ground state of holographic superconductors (at zero temperature), we calculate the conductivity for such models. The universal relation connecting conductivity with the reflection coefficient was used for finding the conductivity by the WKB approach. The dependence of the conductivity on the frequency and charge density is discussed. Numerical calculations confirm the general arguments of (arXiv:0908.3677) in favor of non-zero conductivity even at zero temperature. In addition to the Horowitz-Roberts solution we have found (probably infinite) set of extra solutions which are normalizable and reach the same correct RN-AdS asymptotic at spatial infinity. These extra solutions (which correspond to larger values of the grand canonical potential) lead to effective potentials that also vanish at the horizon and thus correspond to a non-zero conductivity at zero temperature.

R. A. Konoplya; A. Zhidenko

2010-02-15T23:59:59.000Z

331

Thermionic converter temperature controller  

DOE Patents [OSTI]

A method and apparatus for controlling the temperature of a thermionic reactor over a wide range of operating power, including a thermionic reactor having a plurality of integral cesium reservoirs, a honeycomb material disposed about the reactor which has a plurality of separated cavities, a solid sheath disposed about the honeycomb material and having an opening therein communicating with the honeycomb material and cavities thereof, and a shell disposed about the sheath for creating a coolant annulus therewith so that the coolant in the annulus may fill the cavities and permit nucleate boiling during the operation of the reactor.

Shaner, Benjamin J. (McMurray, PA); Wolf, Joseph H. (Pittsburgh, PA); Johnson, Robert G. R. (Trafford, PA)

2001-04-24T23:59:59.000Z

332

Thermionic Converter Temperature Controller  

SciTech Connect (OSTI)

A method and apparatus for controlling the temperature of a thermionic reactor over a wide range of operating power, including a thermionic reactor having a plurality of integral cesium reservoirs, a honeycomb material disposed about the reactor which has a plurality of separated cavities, a solid sheath disposed about the honeycomb material and having an opening therein communicating with the honeycomb material and cavities thereof, and a shell disposed about the sheath for creating a coolant annulus therewith so that the coolant in the annulus may fill the cavities and permit nucleate boiling during the operation of the reactor.

Shaner,B. J.; Wolf, Joseph H.; Johnson, Robert G. R.

1999-08-23T23:59:59.000Z

333

Low-Temperature Geothermal Resources, Geothermal Technologies Program (GTP) (Fact Sheet)  

SciTech Connect (OSTI)

This document highlights the applications of low-temperature geothermal resources and the potential for future uses as well as current Geothermal Technologies Program-funded projects related to low-temperature resources.

Not Available

2010-05-01T23:59:59.000Z

334

Crowdsourcing urban air temperatures from smartphone battery?temperatures  

E-Print Network [OSTI]

Accurate air temperature observations in urban areas are important for meteorology and energy demand planning. They are indispensable to study the urban heat island effect and the adverse effects of high temperatures on ...

Overeem, A.

335

Method for Synthesizing Extremeley High Temperature Melting Materials  

DOE Patents [OSTI]

The invention relates to a method of synthesizing high-temperature melting materials. More specifically the invention relates to a containerless method of synthesizing very high temperature melting materials such as borides, carbides and transition-metal, lanthanide and actinide oxides, using an Aerodynamic Levitator and a laser. The object of the invention is to provide a method for synthesizing extremely high-temperature melting materials that are otherwise difficult to produce, without the use of containers, allowing the manipulation of the phase (amorphous/crystalline/metastable) and permitting changes of the environment such as different gaseous compositions.

Saboungi, Marie-Louise and Glorieux, Benoit

2005-11-22T23:59:59.000Z

336

Method For Synthesizing Extremely High-Temperature Melting Materials  

DOE Patents [OSTI]

The invention relates to a method of synthesizing high-temperature melting materials. More specifically the invention relates to a containerless method of synthesizing very high temperature melting materials such as borides, carbides and transition-metal, lanthanide and actinide oxides, using an Aerodynamic Levitator and a laser. The object of the invention is to provide a method for synthesizing extremely high-temperature melting materials that are otherwise difficult to produce, without the use of containers, allowing the manipulation of the phase (amorphous/crystalline/metastable) and permitting changes of the environment such as different gaseous compositions.

Saboungi, Marie-Louise (Chicago, IL); Glorieux, Benoit (Perpignan, FR)

2005-11-22T23:59:59.000Z

337

Method for synthesizing extremely high-temperature melting materials  

SciTech Connect (OSTI)

The invention relates to a method of synthesizing high-temperature melting materials. More specifically the invention relates to a containerless method of synthesizing very high temperature melting materials such as carbides and transition-metal, lanthanide and actinide oxides, using an aerodynamic levitator and a laser. The object of the invention is to provide a method for synthesizing extremely high-temperature melting materials that are otherwise difficult to produce, without the use of containers, allowing the manipulation of the phase (amorphous/crystalline/metastable) and permitting changes of the environment such as different gaseous compositions.

Saboungi, Marie-Louise (Chicago, IL); Glorieux, Benoit (Perpignan, FR)

2007-11-06T23:59:59.000Z

338

Method And Apparatus For Evaluatin Of High Temperature Superconductors  

DOE Patents [OSTI]

A technique for evaluation of high-T.sub.c superconducting films and single crystals is based on measurement of temperature dependence of differential optical reflectivity of high-T.sub.c materials. In the claimed method, specific parameters of the superconducting transition such as the critical temperature, anisotropy of the differential optical reflectivity response, and the part of the optical losses related to sample quality are measured. The apparatus for performing this technique includes pump and probe sources, cooling means for sweeping sample temperature across the critical temperature and polarization controller for controlling a state of polarization of a probe light beam.

Fishman, Ilya M. (Palo Alto, CA); Kino, Gordon S. (Stanford, CA)

1996-11-12T23:59:59.000Z

339

Philosophy 26 High Temperature Superconductivity  

E-Print Network [OSTI]

Philosophy 26 High Temperature Superconductivity By Ohm's Law, resistance will dim. Low temperature superconductivity was discovered in 1911 by Heike was explained by BCS theory. BCS theory explains superconductivity microscopically

Callender, Craig

340

The Greenhouse Effect Temperature Equilibrium  

E-Print Network [OSTI]

The Greenhouse Effect #12;Temperature Equilibrium The Earth is in equilibrium with the Sun temperature is about 14C, or 287K. The 40K difference is due to the greenhouse effect. Essentially all

Walter, Frederick M.

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Battery system with temperature sensors  

DOE Patents [OSTI]

A battery system to monitor temperature includes at least one cell with a temperature sensing device proximate the at least one cell. The battery system also includes a flexible member that holds the temperature sensor proximate to the at least one cell.

Wood, Steven J.; Trester, Dale B.

2012-11-13T23:59:59.000Z

342

The effect of inter-pass temperature on residual stresses in multi-pass welds produced using a low transformation temperature filler alloy  

E-Print Network [OSTI]

, the deposition of new metal with a relatively low inter-pass temperature leads to increased residual stressesThe effect of inter-pass temperature on residual stresses in multi-pass welds produced using a low-to-martensite transformation temperatures offer an effective method of reducing residual stresses in strong, steel welds

Cambridge, University of

343

Hot Pot Contoured Temperature Gradient Map  

SciTech Connect (OSTI)

Temperature gradient contours derived from Oski temperature gradient hole program and from earlier published information.

Lane, Michael

2013-06-28T23:59:59.000Z

344

Hot Pot Contoured Temperature Gradient Map  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Temperature gradient contours derived from Oski temperature gradient hole program and from earlier published information.

Lane, Michael

345

ARM - Measurement - Atmospheric temperature  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUC : XDCResearch Related InformationAcid RainTheimage ARMtemperature ARM Data

346

Membrane Development for Medium and High Temperature PEMFC in...  

Broader source: Energy.gov (indexed) [DOE]

PEFC and to extend the range of humidity levels at which the MEA can operate Daimler, Germany 8.3 M IPHE-GENIE IPHE for the GENeration of novel IonomEr membranes Association of...

347

HIGH TEMPERATURE HIGH PRESSURE THERMODYNAMIC MEASUREMENTS FOR COAL MODEL COMPOUNDS  

SciTech Connect (OSTI)

It is well known that the fluid phase equilibria can be represented by a number of {gamma}-models , but unfortunately most of them do not function well under high temperature. In this calculation, we mainly investigate the performance of UNIQUAC and NRTL models under high temperature, using temperature dependent parameters rather than using the original formulas. the other feature of this calculation is that we try to relate the excess Gibbs energy G{sup E}and enthalpy of mixing H{sup E}simultaneously. In other words, we will use the high temperature and pressure G{sup E} and H{sup E}data to regress the temperature dependant parameters to find out which model and what kind of temperature dependant parameters should be used.

Vinayak N. Kabadi

1999-02-20T23:59:59.000Z

348

Concept of a thermonuclear reactor based on gravity retention of high-temperature plasma  

E-Print Network [OSTI]

In the present paper the realization of the obtained results in relation to the dense high- temperature plasma of multivalent ions including experimental data interpretation is discussed.

S. I. Fisenko; I. S. Fisenko

2007-05-27T23:59:59.000Z

349

High temperature interfacial superconductivity  

DOE Patents [OSTI]

High-temperature superconductivity confined to nanometer-scale interfaces has been a long standing goal because of potential applications in electronic devices. The spontaneous formation of a superconducting interface in bilayers consisting of an insulator (La.sub.2CuO.sub.4) and a metal (La.sub.1-xSr.sub.xCuO.sub.4), neither of which is superconducting per se, is described. Depending upon the layering sequence of the bilayers, T.sub.c may be either .about.15 K or .about.30 K. This highly robust phenomenon is confined to within 2-3 nm around the interface. After exposing the bilayer to ozone, T.sub.c exceeds 50 K and this enhanced superconductivity is also shown to originate from a 1 to 2 unit cell thick interfacial layer. The results demonstrate that engineering artificial heterostructures provides a novel, unconventional way to fabricate stable, quasi two-dimensional high T.sub.c phases and to significantly enhance superconducting properties in other superconductors. The superconducting interface may be implemented, for example, in SIS tunnel junctions or a SuFET.

Bozovic, Ivan (Mount Sinai, NY); Logvenov, Gennady (Port Jefferson Station, NY); Gozar, Adrian Mihai (Port Jefferson, NY)

2012-06-19T23:59:59.000Z

350

Sonde Adjust Value-Added Product Technical Report  

SciTech Connect (OSTI)

The Sonde Adjust (SONDEADJUST) value-added product (VAP) creates a file that includes all fields from original Atmospheric Radiation Measurement Climate Research Facility (ARM Facility) radiosonde files and contains several value-added fields that provide adjustments related to well-known humidity issues. SONDEADJUST produces data that correct documented biases in radiosonde humidity measurements. Previous efforts towards applying some of these corrections are available via the discontinued PI product sgpsondecorr1miloC1. Unique fields contained within this datastream include smoothed original relative humidity, dry bias corrected relative humidity, and final corrected relative humidity. The smoothed RH field refines the relative humidity from integers-the resolution of the instrument-to fractions of a percent. This profile is then used to calculate the dry bias corrected field. The final correction fixes the time-lag problem and uses the dry-bias field as input into the algorithm. In addition to dry bias, solar heating is another correction that is encompassed in the final corrected RH field. Output from SONDEADJUST differs from the previous RH-corrected datastreams in important ways. First, all three types of ARM radiosondes-Vaisala RS-80, RS-90, and RS-92-are corrected using dedicated procedures and/or parameters. Second, the output variables include all of those found in the original radiosonde file: dry bulb temperature, dewpoint temperature, wind speed, wind direction, eastward wind component, northward wind component, wind status (a Vaisala-produced field used in conjunction with the Loran system), ascent rate, and original relative humidity. Additional humidity fields are smoothed relative humidity, dry biased corrected relative humidity, final ambient relative humidity, and scaled adjusted relative humidity. Third, quality control (QC) flags of the fields from the original radiosonde datastream are brought into the SONDEADJUST output file. Additional QC variables are created for the new fields.

Troyan, D

2012-01-09T23:59:59.000Z

351

Measurement of thermodynamic temperature of high temperature fixed points  

SciTech Connect (OSTI)

The paper is devoted to VNIIOFI's measurements of thermodynamic temperature of the high temperature fixed points Co-C, Pt-C and Re-C within the scope of the international project coordinated by the Consultative Committee for Thermometry working group 5 'Radiation Thermometry'. The melting temperatures of the fixed points were measured by a radiance mode radiation thermometer calibrated against a filter radiometer with known irradiance spectral responsivity via a high temperature black body. This paper describes the facility used for the measurements, the results and estimated uncertainties.

Gavrilov, V. R.; Khlevnoy, B. B.; Otryaskin, D. A.; Grigorieva, I. A.; Samoylov, M. L.; Sapritsky, V. I. [All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), 46 Ozernaya St., Moscow 119361 (Russian Federation)] [All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), 46 Ozernaya St., Moscow 119361 (Russian Federation)

2013-09-11T23:59:59.000Z

352

High-temperature Pump Monitoring - High-temperature ESP Monitoring...  

Broader source: Energy.gov (indexed) [DOE]

Report Detecting Fractures Using Technology at High Temperatures and Depths - Geothermal Ultrasonic Fracture Imager (GUFI); 2010 Geothermal Technology Program Peer Review Report...

353

Evaluation of building and occupant response to temperature and humidity: non-traditional heat stress considerations A comparison of different construction types used by the Texas Department of Criminal Justice  

E-Print Network [OSTI]

stifling hot in the summer and damp cold in the winter. The design and construction of dedicated prison facilities continued to progress slowly, but is was not until the 18th century and a review of world prisons by John Howard (State of the Prisons... at Dallas Chair of Advisory Committee: Dr. James C. Rock This study examined the effects of construction types on the indoor environment of selected prison facilities in the State of Texas. Three collocated facilities of the Texas Department...

Nalbone, Joseph Torey

2005-02-17T23:59:59.000Z

354

Actinide Thermodynamics at Elevated Temperatures  

SciTech Connect (OSTI)

The postclosure chemical environment in the proposed Yucca Mountain repository is expected to experience elevated temperatures. Predicting migration of actinides is possible if sufficient, reliable thermodynamic data on hydrolysis and complexation are available for these temperatures. Data are scarce and scattered for 25 degrees C, and nonexistent for elevated temperatures. This collaborative project between LBNL and PNNL collects thermodynamic data at elevated temperatures on actinide complexes with inorganic ligands that may be present in Yucca Mountain. The ligands include hydroxide, fluoride, sulfate, phosphate and carbonate. Thermodynamic parameters of complexation, including stability constants, enthalpy, entropy and heat capacity of complexation, are measured with a variety of techniques including solvent extraction, potentiometry, spectrophotometry and calorimetry

Friese, Judah I.; Rao, Linfeng; Xia, Yuanxian; Bachelor, Paula P.; Tian, Guoxin

2007-11-16T23:59:59.000Z

355

High Temperature Processing Symposium 2014  

E-Print Network [OSTI]

} High temperature recycling operations } Materials sustainability } New furnace technology (including solar) We look forward to seeing you in February 2014. Dr M Akbar Rhamdhani (Chairman HTPS 2014) Prof

Liley, David

356

Low Temperature Material Bonding Technique  

DOE Patents [OSTI]

A method of performing a lower temperature bonding technique to bond together two mating pieces of glass includes applying a sodium silicate aqueous solution between the two pieces.

Ramsey, J. Michael (Knoxville, TN); Foote, Robert S. (Oak Ridge, TN)

2000-10-10T23:59:59.000Z

357

Low temperature material bonding technique  

DOE Patents [OSTI]

A method of performing a lower temperature bonding technique to bond together two mating pieces of glass includes applying a sodium silicate aqueous solution between the two pieces.

Ramsey, J. Michael (Knoxville, TN); Foote, Robert S. (Oak Ridge, TN)

2002-02-12T23:59:59.000Z

358

Breakdown of time-temperature superposition in a bead-spring polymer melt near the glass transition temperature  

E-Print Network [OSTI]

The breakdown of the time-temperature superposition (TTS) near its glass transition temperature (Tg) in simple bead-spring polymer melts with and without the chain angle potential was numerically investigated. The stress relaxation modulus at different temperatures G(t,T) was calculated by the Green-Kubo relation. The TTS of G(t,T) of bead-spring polymer melts worked well at temperatures sufficiently higher than its Tg. However, when the system temperature is approaching the glass transition regime, the breakdown of TTS is observed. At temperatures near the Tg, the temperature dependence of the shift factor aTB, which is defined at the time scale between the bond relaxation and the chain relaxation regimes of a G(t)-function, is significantly stronger than ones aTA defined by the time scale of the chain relaxation modes. In direct relation to the breakdown of TTS of G(t,T), the decoupling of Stokes-Einstein law of diffusion-viscosity relation also appears in the glass transition regime. The analysis of the van Hove function Gs(r,t) and non-gaussian parameter, a2(t), of the bead motions strongly suggest that the TTS breakdown is concerned with the dynamic heterogeneity. The effect of the chain stiffness on the temperature dependence of the shift factors was also investigated in this study. The stiffer chains melt has a stronger temperature dependence of the shift factors than the ones of the flexible chains melt. However, regardless of the chain stiffness, the stress relaxation modulus functions of the bead-spring polymer melts will begin to breakdown the TTS at a similar Tg-normalized temperature around T/Tg ~ 1.2.

Tamio Yamazaki

2014-10-06T23:59:59.000Z

359

Initial Evaluation of Smart Irrigation Controllers: Year Two (2009) Results  

E-Print Network [OSTI]

controller or a computer which is connected to an on-site weather station equipped with senors that record temperature, relative humidity (or dew point temperature) wind speed and solar radiation for use in calculating ETo with a form of the Penman... with a standard agricultural weather station which records temperature, solar radiation, wind and relative humidity. ETo was computed using the standardized Penman-Monteith method. ETo and Rainfall rates during the evaluation period are given...

Swanson, Charles; Fipps, Guy

360

Evaluation of Smart Irrigation Controllers: Initial Bench Testing Results  

E-Print Network [OSTI]

-site weather station equipped with senors that record temperature, relative humidity (or dew point temperature) wind speed and solar radiation for use in calculating ETo with a form of the Penman equation. 4 MATERIALS AND METHODS Testing Equipment... in College Station, TX. The weather parameters were measured with a standard agricultural weather station which records temperature, solar radiation, wind and relative humidity. The ETo was computed using the standardized Penman-Monteith method. 7 RESULTS...

Swanson, Charles; Fipps, Guy

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Condensation temperature trends among stars with planets  

E-Print Network [OSTI]

Results from detailed spectroscopic analyses of stars hosting massive planets are employed to search for trends between abundances and condensation temperatures. The elements C, S, Na, Mg, Al, Ca, Sc, Ti, V, Cr, Mn, Fe, Ni and Zn are included in the analysis of 64 stars with planets and 33 comparison stars. No significant trends are evident in the data. This null result suggests that accretion of rocky material onto the photospheres of stars with planets is not the primary explanation for their high metallicities. However, the differences between the solar photospheric and meteoritic abundances do display a weak but significant trend with condensation temperature. This suggests that the metallicity of the sun's envelope has been enriched relative to its interior by about 0.07 dex.

Guillermo Gonzalez

2005-12-08T23:59:59.000Z

362

Experiment Hazard Class 3 - High Temperatures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Operation * APS Base Low Temperatures * Cryogenic Systems High Temperatures * Electric Furnace * Optical Furnace * Other High Temperature Lasers * Laser, Class 2 * Laser,...

363

High temperature solar selective coatings  

DOE Patents [OSTI]

Improved solar collectors (40) comprising glass tubing (42) attached to bellows (44) by airtight seals (56) enclose solar absorber tubes (50) inside an annular evacuated space (54. The exterior surfaces of the solar absorber tubes (50) are coated with improved solar selective coatings {48} which provide higher absorbance, lower emittance and resistance to atmospheric oxidation at elevated temperatures. The coatings are multilayered structures comprising solar absorbent layers (26) applied to the meta surface of the absorber tubes (50), typically stainless steel, topped with antireflective Savers (28) comprising at least two layers 30, 32) of refractory metal or metalloid oxides (such as titania and silica) with substantially differing indices of refraction in adjacent layers. Optionally, at least one layer of a noble metal such as platinum can be included between some of the layers. The absorbent layers cars include cermet materials comprising particles of metal compounds is a matrix, which can contain oxides of refractory metals or metalloids such as silicon. Reflective layers within the coating layers can comprise refractory metal silicides and related compounds characterized by the formulas TiSi. Ti.sub.3SiC.sub.2, TiAlSi, TiAN and similar compounds for Zr and Hf. The titania can be characterized by the formulas TiO.sub.2, Ti.sub.3O.sub.5. TiOx or TiO.sub.xN.sub.1-x with x 0 to 1. The silica can be at least one of SiO.sub.2, SiO.sub.2x or SiO.sub.2xN.sub.1-x with x=0 to 1.

Kennedy, Cheryl E

2014-11-25T23:59:59.000Z

364

IEEE BCTM5.1 Dependenceof ThermalResistanceon Ambientand Actual Temperature  

E-Print Network [OSTI]

resistance is inversely proportional to the thermal conductivity. This means that the temperature behaviour of the thermal resistance as function of power dissipation at constant ambient, but increasing device temperature increases the thermal resistance. The relation between temperature and power dissipation is then no longer

Technische Universiteit Delft

365

Model Based Sensor System for Temperature Measurement in R744 Air Conditioning Systems  

E-Print Network [OSTI]

The goal is the development of a novel principle for the temperature acquisition of refrigerants in CO2 air conditioning systems. The new approach is based on measuring the temperature inside a pressure sensor, which is also needed in the system. On the basis of simulative investigations of different mounting conditions functional relations between measured and medium temperature will be derived.

Reitz, Sven; Schneider, Peter

2008-01-01T23:59:59.000Z

366

Statistics of particle time-temperature histories.  

SciTech Connect (OSTI)

Particles in non - isothermal turbulent flow are subject to a stochastic environment tha t produces a distribution of particle time - temperature histories. This distribution is a function of the dispersion of the non - isothermal (continuous) gas phase and the distribution of particles relative to that gas phase. In this work we extend the one - dimensional turbulence (ODT) model to predict the joint dispersion of a dispersed particle phase and a continuous phase. The ODT model predicts the turbulent evolution of continuous scalar fields with a model for the cascade of fluctuations to smaller sc ales (the 'triplet map') at a rate that is a function of the fully resolved one - dimens ional velocity field . Stochastic triplet maps also drive Lagrangian particle dispersion with finite Stokes number s including inertial and eddy trajectory - crossing effect s included. Two distinct approaches to this coupling between triplet maps and particle dispersion are developed and implemented along with a hybrid approach. An 'instantaneous' particle displacement model matches the tracer particle limit and provide s an accurate description of particle dispersion. A 'continuous' particle displacement m odel translates triplet maps into a continuous velocity field to which particles respond. Particles can alter the turbulence, and modifications to the stochastic rate expr ession are developed for two - way coupling between particles and the continuous phase. Each aspect of model development is evaluated in canonical flows (homogeneous turbulence, free - shear flows and wall - bounded flows) for which quality measurements are ava ilable. ODT simulations of non - isothermal flows provide statistics for particle heating. These simulations show the significance of accurately predicting the joint statistics of particle and fluid dispersion . Inhomogeneous turbulence coupled with the in fluence of the mean flow fields on particles of varying properties alter s particle dispersion. The joint particle - temperature dispersion leads to a distribution of temperature histories predicted by the ODT . Predictions are shown for the lower moments an d the full distributions of the particle positions, particle - observed gas temperatures and particle temperatures. An analysis of the time scales affecting particle - temperature interactions covers Lagrangian integral time scales based on temperature autoco rrelations, rates of temperature change associated with particle motion relative to the temperature field and rates of diffusional change of temperatures. These latter two time scales have not been investigated previously; they are shown to be strongly in termittent having peaked distributions with long tails. The logarithm of the absolute value of these time scales exhibits a distribution closer to normal. A cknowledgements This work is supported by the Defense Threat Reduction Agency (DTRA) under their Counter - Weapons of Mass Destruction Basic Research Program in the area of Chemical and Biological Agent Defeat under award number HDTRA1 - 11 - 4503I to Sandia National Laboratories. The authors would like to express their appreciation for the guidance provi ded by Dr. Suhithi Peiris to this project and to the Science to Defeat Weapons of Mass Destruction program.

Hewson, John C.; Lignell, David O.; Sun, Guangyuan

2014-10-01T23:59:59.000Z

367

Control of household refrigerators. Part 1: Modeling temperature control performance  

SciTech Connect (OSTI)

Commercial household refrigerators use simple, cost-effective, temperature controllers to obtain acceptable control. A manually adjusted airflow damper regulates the freezer compartment temperature while a thermostat controls operation of the compressor and evaporator fan to regulate refrigerator compartment temperature. Dual compartment temperature control can be achieved with automatic airflow dampers that function independently of the compressor and evaporator fan thermostat, resulting in improved temperature control quality and energy consumption. Under dual control, freezer temperature is controlled by the thermostat while the damper controls refrigerator temperature by regulating airflow circulation. A simulation model is presented that analyzes a household refrigerator configured with a conventional thermostat and both manual and automatic dampers. The model provides a new paradigm for investigating refrigerator systems and temperature control performance relative to the extensive verification testing that is typically done by manufacturers. The effects of each type of control and damper configuration are compared with respect to energy usage, control quality, and ambient temperature shift criteria. The results indicate that the appropriate control configuration can have significant effects and can improve plant performance.

Graviss, K.J.; Collins, R.L.

1999-07-01T23:59:59.000Z

368

Perspectives on Temperature in the Pacific Northwest's Fresh Waters  

SciTech Connect (OSTI)

This report provides a perspective on environmental water temperatures in the Pacific Northwest as they relate to the establishment of water temperature standards by the state and their review by the US Environmental Protection Agency. It is a companion to other detailed reviews of the literature on thermal effects on organisms important to the region. Many factors, both natural and anthropogenic, affect water temperatures in the region. Different environmental zones have characteristic temperatures and mechanisms that affect them. There are specific biotic adaptations to environmental temperatures. Life-cycle strategies of salmonids, in particular, are attuned to annual temperature patterns. Physiological and behavioral requirements on key species form the basis of present water temperature criteria, but may need to be augmented with more concern for environmental settings. There are many issues in the setting of standards, and these are discussed. There are also issues in compliance. Alternative temperature-regulating mechanisms are discussed, as are examples of actions to control water temperatures in the environment. Standards-setting is a social process for which this report should provide background and outline options, alternatives, limitations, and other points for discussion by those in the region.

Coutant, C.C.

1999-06-01T23:59:59.000Z

369

Low temperature irradiation tests on  

E-Print Network [OSTI]

Sample cool down by He gas loop 10K ­ 20K Fast neutron flux Measured by Ni activation in 2010 1.4xK #12;reactor Cryogenics #12;Al-Cu-Mg He gas temperature near sample 12K Resistance changesLow temperature irradiation tests on stabilizer materials using reactor neutrons at KUR Makoto

McDonald, Kirk

370

Temperature limited heater utilizing non-ferromagnetic conductor  

DOE Patents [OSTI]

A heater is described. The heater includes a ferromagnetic conductor and an electrical conductor electrically coupled to the ferromagnetic conductor. The ferromagnetic conductor is positioned relative to the electrical conductor such that an electromagnetic field produced by time-varying current flow in the ferromagnetic conductor confines a majority of the flow of the electrical current to the electrical conductor at temperatures below or near a selected temperature.

Vinegar; Harold J. (Bellaire, TX), Harris; Christopher Kelvin (Houston, TX)

2012-07-17T23:59:59.000Z

371

Detecting temperature fluctuations at equilibrium  

E-Print Network [OSTI]

Gibbs and Boltzmann definitions of temperature agree only in the macroscopic limit. The ambiguity in identifying the equilibrium temperature of a finite sized `small' system exchanging energy with a bath is usually understood as a limitation of conventional statistical mechanics. We interpret this ambiguity as resulting from a stochastically fluctuating temperature coupled with the phase space variables giving rise to a broad temperature distribution. With this ansatz, we develop the equilibrium statistics and dynamics of small systems. Numerical evidence using an analytically tractable model shows that the effects of temperature fluctuations can be detected in equilibrium and dynamical properties of the phase space of the small system. Our theory generalizes statistical mechanics to small systems relevant to biophysics and nanotechnology.

Dixit, Purushottam D

2015-01-01T23:59:59.000Z

372

Low exhaust temperature electrically heated particulate matter filter system  

DOE Patents [OSTI]

A system includes a particulate matter (PM) filter, a sensor, a heating element, and a control module. The PM filter includes with an upstream end that receives exhaust gas, a downstream end and multiple zones. The sensor detects a temperature of the exhaust gas. The control module controls current to the heating element to convection heat one of the zones and initiate a regeneration process. The control module selectively increases current to the heating element relative to a reference regeneration current level when the temperature is less than a predetermined temperature.

Gonze, Eugene V. (Pinckney, MI); Paratore, Jr., Michael J. (Howell, MI); Bhatia, Garima (Bangalore, IN)

2012-02-14T23:59:59.000Z

373

Impact Strength of High Relative Density Solid State CO, Blown CPET Microcellular Foams Impact Strength of High Relative Density  

E-Print Network [OSTI]

is an increased glass transition temperature (T,), thus requiring higher foaming temperatures. Baldwin and SuhImpact Strength of High Relative Density Solid State CO, Blown CPET Microcellular Foams ImpactTerephthalate) Microcellular Foams Vipin KurnaW, Richard P Juntunena, and Chris Barlowb University of Washington, Seattle

Kumar, Vipin

374

An investigation of the heat and mass transfer by free convection from humid air to a horizontal metal plate under frosting conditions  

E-Print Network [OSTI]

analysis by C. A . Whitehurst (6) showed that the temperature and concentration boundary layer profile curves were approximately parabolic. These curves are plotted as dimensionless ~ters, p and g , versus the ratios respectively, in Figures 18 and. 14...+. On the top side of the plate all runs except 5 and. 8 came very close to being parabolic curves for the temperature profile curves, with 5 and 8 taking on a parabolic characteristic at about, half way through the boundary layer. However, the concentration...

Bell, Bobby

1967-01-01T23:59:59.000Z

375

Effect of Gas Turbine Exhaust Temperature, Stack Temperature and Ambient Temperature on Overall Efficiency of Combine Cycle Power Plant  

E-Print Network [OSTI]

Abstract—The gas turbine exhaust temperature, stack temperature and ambient temperature play a very important role during the predication of the performance of combine cycle power plant. This paper covers parametric analysis of effects of gas turbine exhaust temperature, stack temperature and ambient temperature on the overall efficiency of combine cycle power plant keeping the gas turbine efficiency as well as steam turbine efficiency constant. The results shows that out of three variables i.e. turbine exhaust temperature, stack temperature and ambient temperature, the most dominating factor of increasing the overall efficiency of the combine cycle power plant is the stack temperature.

unknown authors

377

O.Traull CNRM/GMEI/TRAMM mai 2013 High frequency measurements over an instrumented profile  

E-Print Network [OSTI]

(ventilated and not ventilated), relative humidity, wind speed and direction. 3. 1 minute solar radiation tower with multi levels wind sensors : sonics propellers humidity and temperature probes with radiation shielded sensors, ventilated or not Prevailing winds WW N-W guy wires SSWSSW #12;8 O.Traullé CNRM

Ribes, Aurélien

378

Watching ColoradoWatching Colorado WeatherWeather  

E-Print Network [OSTI]

with daily and hourly readings of: ­ Temperature ­ Humidity ­ Wind ­ Precipitation ­ Solar energy #12;Hoehne Relative Humidity #12;Hoehne Solar Radiation #12;Hoehne Wind Speed #12;Hoehne ET Reference Basin April 1 Snowpack #12;How are we doing this year? #12;Canon City Canon City 2005 Water Year 0 5 10

379

Shock temperature measurements in ammonia  

SciTech Connect (OSTI)

Our first shock temperature measurements on a cryogenic target are reported for NH/sub 3/. A new fast optical pyrometer and a cryogenic specimen holder for liquid NH/sub 3/ were developed to measure shock temperatures of 4400 and 3600 K at pressures of 61 and 48 GPa. These conditions correspond to those in the ice layers in Uranus and Neptune. The shock temperature data are in reasonable agreement with an equation of state based on an intermolecular potential derived from NH/sub 3/ Hugoniot data.

Radousky, H.B.; Mitchell, A.C.; Nellis, W.J.; Ross, M.

1985-07-01T23:59:59.000Z

380

A Dynamical Approach to Temperature  

E-Print Network [OSTI]

We present a new dynamical approach for measuring the temperature of a Hamiltonian dynamical system in the micro canonical ensemble of thermodynamics. We show that under the hypothesis of ergodicity the temperature can be computed as a time-average of the functional, div(grad H/|grad H|^2), on the energy-surface. Our method not only yields an efficient computational approach for determining the temperature it also provides an intrinsic link between dynamical systems theory and the statistical mechanics of Hamiltonian systems.

Hans Henrik Rugh

1997-01-30T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Emergency building temperature restrictions. Final evaluation  

SciTech Connect (OSTI)

On July 5, 1979, DOE promulgated final regulations of the Emergency Building Temperature Restrictions program, placing emergency restrictions on thermostat settings for space heating, space cooling, and hot water in commercial, industrial, and nonresidential public buildings. The final regulations restricted space heating to a maximum of 65/sup 0/F, hot water temperature to a maximum of 105/sup 0/F, and cooling temperature to a minimum of 78/sup 0/F. A comprehensive evaluation of the entire EBTF program for a nine-month period from July 16, 1979 is presented. In Chapter 1, an estimate of the population of buildings covered by EBTR is presented. In Chapter 2, EBTR compliance by building type and region is reported. Exemptions are also discussed. In Chapter 3, the simulations of building energy use are explained and the relative impact of various building characteristics and effectiveness of different control strategies are estimated. Finally, in Chapter 4, the methodology for scaling the individual building energy savings to the national level is described, and estimated national energy savings are presented.

None

1980-11-01T23:59:59.000Z

382

Thermodynamics and scale relativity  

E-Print Network [OSTI]

It is shown how the fractal paths of scale relativity (following Nottale) can be introduced into a thermodynamical context (following Asadov-Kechkin).

Robert Carroll

2011-10-13T23:59:59.000Z

383

Community Relations Plan  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

the Permittees and the public are documented during the Hazardous Waste Facility Permit Community Relations Plan development. Contact Environmental Communication & Public...

384

Innovative Instrumentation and Analysis of the Temperature Measurement for High Temperature Gasification  

SciTech Connect (OSTI)

The project entitled, ''Innovative Instrumentation and Analysis of the Temperature Measurement for High Temperature Gasification'', was successfully completed by the Principal Investigator, Dr. S. Lee and his research team in the Center for Advanced Energy Systems and Environmental Control Technologies at Morgan State University. The major results and outcomes were presented in semi-annual progress reports and annual project review meetings/presentations. Specifically, the literature survey including the gasifier temperature measurement, the ultrasonic application in cleaning application, and spray coating process and the gasifier simulator (cold model) testing has been successfully conducted during the first year. The results show that four factors (blower voltage, ultrasonic application, injection time intervals, particle weight) were considered as significant factors that affect the temperature measurement. Then the gasifier simulator (hot model) design and the fabrication as well as the systematic tests on hot model were completed to test the significant factors on temperature measurement in the second year. The advanced Industrial analytic methods such as statistics-based experimental design, analysis of variance (ANOVA) and regression methods were applied in the hot model tests. The results show that operational parameters (i.e. air flow rate, water flow rate, fine dust particle amount, ammonia addition) presented significant impact on the temperature measurement inside the gasifier simulator. The experimental design and ANOVA are very efficient way to design and analyze the experiments. The results show that the air flow rate and fine dust particle amount are statistically significant to the temperature measurement. The regression model provided the functional relation between the temperature and these factors with substantial accuracy. In the last year of the project period, the ultrasonic and subsonic cleaning methods and coating materials were tested/applied on the thermocouple cleaning according to the proposed approach. Different frequency, application time and power of the ultrasonic/subsonic output were tested. The results show that the ultrasonic approach is one of the best methods to clean the thermocouple tips during the routine operation of the gasifier. In addition, the real time data acquisition system was also designed and applied in the experiments. This advanced instrumentation provided the efficient and accurate data acquisition for this project. In summary, the accomplishment of the project provided useful information of the ultrasonic cleaning method applied in thermocouple tip cleaning. The temperature measurement could be much improved both in accuracy and duration provided that the proposed approach is widely used in the gasification facilities.

Seong W. Lee

2006-09-30T23:59:59.000Z

385

LOW TEMPERATURE CATHODE SUPPORTED ELECTROLYTES  

SciTech Connect (OSTI)

This project has three main goals: Thin Films Studies, Preparation of Graded Porous Substrates and Basic Electrical Characterization and testing of Planar Single Cells. This period has continued to address the problem of making dense 1/2 to 5 {micro}m thick dense layers on porous substrates (the cathode LSM). Our current status is that we are making structures of 2-5 cm{sup 2} in area, which consist of either dense YSZ or CGO infiltrated into a 2-5 {micro}m thick 50% porous layer made of either nanoncrystalline CGO or YSZ powder. This composite structure coats a macroporous cathode or anode; which serves as the structural element of the bi-layer structure. These structures are being tested as SOFC elements. A number of structures have been evaluated both as symmetrical and as button cell configuration. Results of this testing indicates that the cathodes contribute the most to cell losses for temperatures below 750 C. In this investigation different cathode materials were studied using impedance spectroscopy of symmetric cells and IV characteristics of anode supported fuel cells. Cathode materials studied included La{sub 0.8}Sr{sub 0.2}Co{sub 0.2}Fe{sub 0.8}O{sub 3} (LSCF), La{sub 0.7}Sr{sub 0.2}MnO{sub 3} (LSM), Pr{sub 0.8}Sr{sub 0.2}Fe{sub 0.8}O{sub 3} (PSCF), Sm{sub 0.8}Sr{sub 0.2}Co{sub 0.2}Fe{sub 0.8}O{sub 3} (SSCF), and Yb{sub .8}Sr{sub 0.2}Co{sub 0.2}Fe{sub 0.8}O{sub 3} (SSCF). A new technique for filtering the Fourier transform of impedance data was used to increase the sensitivity of impedance analysis. By creating a filter specifically for impedance spectroscopy the resolution was increased. The filter was tailored to look for specific circuit elements like R//C, Warburg, or constant phase elements. As many as four peaks can be resolved using the filtering technique on symmetric cells. It may be possible to relate the different peaks to material parameters, like the oxygen exchange coefficient. The cathode grouped in order from lowest to highest ASR is LSCF < PSCF < SSCF < YSCF < LSM. The button cell results agree with this ordering indicating that this is an important tool for use in developing our understanding of electrode behavior in fuel cells.

Harlan U. Anderson; Fatih Dogan; Vladimir Petrovsky

2002-03-31T23:59:59.000Z

386

temperature heat pumps applied to  

E-Print Network [OSTI]

Very high- temperature heat pumps applied to energy efficiency in industry Application June 21th 2012 Energy efficiency : A contribution to environmental protection Kyoto Copenhage Emission, plastics Partnership : EDF R&D Bil

Oak Ridge National Laboratory

387

Conducting polymer actuators : temperature effects  

E-Print Network [OSTI]

In order to utilize conducting polymer actuators as a viable engineering solution, it is necessary to produce usable levels of force with a reasonable bandwidth. Polypyrrole actuated at temperatures as high as 100 °C ...

Del Zio, Michael R. (Michael Robert), 1982-

2006-01-01T23:59:59.000Z

388

High temperature structural insulating material  

DOE Patents [OSTI]

A high temperature structural insulating material useful as a liner for cylinders of high temperature engines through the favorable combination of high service temperature (above about 800/sup 0/C), low thermal conductivity (below about 0.2 W/m/sup 0/C), and high compressive strength (above about 250 psi). The insulating material is produced by selecting hollow ceramic beads with a softening temperature above about 800/sup 0/C, a diameter within the range of 20-200 ..mu..m, and a wall thickness in the range of about 2 to 4 ..mu..m; compacting the beads and a compatible silicate binder composition under pressure and sintering conditions to provide the desired structural form with the structure having a closed-cell, compact array of bonded beads.

Chen, W.Y.

1984-07-27T23:59:59.000Z

389

High temperature structural insulating material  

DOE Patents [OSTI]

A high temperature structural insulating material useful as a liner for cylinders of high temperature engines through the favorable combination of high service temperature (above about 800.degree. C.), low thermal conductivity (below about 0.2 W/m.degree. C.), and high compressive strength (above about 250 psi). The insulating material is produced by selecting hollow ceramic beads with a softening temperature above about 800.degree. C., a diameter within the range of 20-200 .mu.m, and a wall thickness in the range of about 2-4 .mu.m; compacting the beads and a compatible silicate binder composition under pressure and sintering conditions to provide the desired structural form with the structure having a closed-cell, compact array of bonded beads.

Chen, Wayne Y. (Munster, IN)

1987-01-01T23:59:59.000Z

390

Fuel Temperature Coefficient of Reactivity  

SciTech Connect (OSTI)

A method for measuring the fuel temperature coefficient of reactivity in a heterogeneous nuclear reactor is presented. The method, which is used during normal operation, requires that calibrated control rods be oscillated in a special way at a high reactor power level. The value of the fuel temperature coefficient of reactivity is found from the measured flux responses to these oscillations. Application of the method in a Savannah River reactor charged with natural uranium is discussed.

Loewe, W.E.

2001-07-31T23:59:59.000Z

391

PHOTOSYNTHESIS AND RELATED PROCESSES  

E-Print Network [OSTI]

#12;#12;#12;#12;PHOTOSYNTHESIS AND RELATED PROCESSES VOLUME II Part 2 #12;« '«;- py as- b^ Section Research, 7, 288, 1954). #12;PHOTOSYNTHESIS nnd Related Processes By EUGENE I. RABINOWITCH Research Professor, Photosynthesis Research Labora- tory, Department of Botany, University of Illinois. Formerly

Govindjee

392

Novel, fiber optic, hybrid pressure and temperature sensor designed for high-temperature gen-IV reactor applications  

SciTech Connect (OSTI)

A novel, fiber optic, hybrid pressure-temperature sensor is presented. The sensor is designed for reliable operation up to 1050 C, and is based on the high-temperature fiber optic sensors already demonstrated during previous work. The novelty of the sensors presented here lies in the fact that pressure and temperature are measured simultaneously with a single fiber and a single transducer. This hybrid approach will enable highly accurate active temperature compensation and sensor self-diagnostics not possible with other platforms. Hybrid pressure and temperature sensors were calibrated by varying both pressure and temperature. Implementing active temperature compensation resulted in a ten-fold reduction in the temperature-dependence of the pressure measurement. Sensors were also tested for operability in a relatively high neutron radiation environment up to 6.9x10{sup 17} n/cm{sup 2}. In addition to harsh environment survivability, fiber optic sensors offer a number of intrinsic advantages for nuclear power applications including small size, immunity to electromagnetic interference, self diagnostics / prognostics, and smart sensor capability. Deploying fiber optic sensors on future nuclear power plant designs would provide a substantial improvement in system health monitoring and safety instrumentation. Additional development is needed, however, before these advantages can be realized. This paper will highlight recent demonstrations of fiber optic sensors in environments relevant to emerging nuclear power plants. Successes and lessons learned will be highlighted. (authors)

Palmer, M. E.; Fielder, R. S.; Davis, M. A. [Luna Innovations, Incorporated, 2851 Commerce St., Blacksburg, VA 24060 (United States)

2006-07-01T23:59:59.000Z

393

Low to moderate temperature nanolaminate heater  

DOE Patents [OSTI]

A low to moderate temperature heat source comprising a high temperature energy source modified to output low to moderate temperatures wherein the high temperature energy source modified to output low to moderate temperatures is positioned between two thin pieces to form a close contact sheath. In one embodiment the high temperature energy source modified to output low to moderate temperatures is a nanolaminate multilayer foil of reactive materials that produces a heating level of less than 200.degree. C.

Eckels, J. Del (Livermore, CA); Nunes, Peter J. (Danville, CA); Simpson, Randall L. (Livermore, CA); Hau-Riege, Stefan (Fremont, CA); Walton, Chris (Oakland, CA); Carter, J. Chance (Livermore, CA); Reynolds, John G. (San Ramon, CA)

2011-01-11T23:59:59.000Z

394

High temperature thermometric phosphors for use in a temperature sensor  

DOE Patents [OSTI]

A high temperature phosphor consists essentially of a material having the general formula LuPO.sub.4 :Dy.sub.(x),Eu.sub.(y), wherein: 0.1 wt %.ltoreq.x.ltoreq.20 wt % and 0.1 wt %.ltoreq.y.ltoreq.20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopent. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions.

Allison, Stephen W. (Knoxville, TN); Cates, Michael R. (Oak Ridge, TN); Boatner, Lynn A. (Oak Ridge, TN); Gillies, George T. (Earlysville, VA)

1998-01-01T23:59:59.000Z

395

New framework hydrous silicate K{sub 3}Sc[Si{sub 3}O{sub 9}] {center_dot} H{sub 2}O related to the high-temperature anhydrous silicate K{sub 3}Ho[Si{sub 3}O{sub 9}] and symmetry analysis of a phase transition with prediction of structures  

SciTech Connect (OSTI)

Crystals of a new framework silicate K{sub 3}Sc[Si{sub 3}O{sub 9}] {center_dot} H{sub 2}O, space group Pm2{sub 1}n (nonstandard setting of space group Pmn2{sub 1} = C{sub 2v}{sup 7}), are obtained under hydrothermal conditions. The structure is determined without preliminary knowledge of the chemical formula. The absolute configuration is determined. The structure is close to that of the high-temperature K{sub 3}Ho[Si{sub 3}O{sub 9}] phase, which was obtained upon the heating of K{sub 3}HoSi{sub 3}O{sub 8}(OH){sub 2}. This structural similarity is due to the specific conditions of synthesis and an analogous formula, where holmium is replaced by scandium. A symmetry analysis shows that the high local symmetry of a block (rod) is responsible for the first-order phase transition of both the order-disorder (OD) and displacement type. The number of structures in which the simplest and high-symmetry layers are multiplied by different symmetry elements are predicted.

Belokoneva, E. L., E-mail: elbel@geol.msu.ru; Zorina, A. P.; Dimitrova, O. V. [Moscow State University, Faculty of Geology (Russian Federation)

2013-07-15T23:59:59.000Z

396

05684ArcticLakes | netl.doe.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

the gravel pit. A tower near the snow fence was equipped with a data logger, power, solar panel, camera, antenna, radio, and relative humidity and air temperature sensors to...

397

A New Protocol for Evaluating Concrete Curing Effectiveness  

E-Print Network [OSTI]

and qualify the curing compound, a new evaluation protocol is introduced in this study. The new protocol consists of using measured relative humidity and temperature to calculate an effectiveness index (EI) which serves as an indicator of the effectiveness...

Sun, Peizhi

2013-07-22T23:59:59.000Z

398

Operation of Energy Efficient Residential Buildings Under Indoor Environmental Quality Requirements  

E-Print Network [OSTI]

temperature against indoor relative humidity for the same comfort sensation. These two concepts will save 17% to 22% of the project total energy demand, In addition to introducing new design criteria for acceptable indoor conditions in the new rural developed...

Medhat, A. A.; Khalil, E. E.

2010-01-01T23:59:59.000Z

399

Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit, Annapolis, Maryland (Fact Sheet), Building America Case Study: Whole-House Solutions for Existing Homes, Building Technologies Office (BTO)  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd: Scope ChangeL-01-06Hot-Humid-BasicHardware inThermalDesign

400

Thermal disconnect for high-temperature batteries  

DOE Patents [OSTI]

A new type of high temperature thermal disconnect has been developed to protect electrical and mechanical equipment from damage caused by operation at extreme temperatures. These thermal disconnects allow continuous operation at temperatures ranging from 250.degree. C. to 450.degree. C., while rapidly terminating operation at temperatures 50.degree. C. to 150.degree. C. higher than the continuous operating temperature.

Jungst, Rudolph George (Albuquerque, NM); Armijo, James Rudolph (Albuquerque, NM); Frear, Darrel Richard (Austin, TX)

2000-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature?  

E-Print Network [OSTI]

The supply air temperature set point for a singleduct constant air volume air handling unit (AHU) system is often reset based on either return air temperature or outside air temperature in order to reduce simultaneous cooling and heating energy...

Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

2002-01-01T23:59:59.000Z

402

Finite Temperature Closed Superstring Theory  

E-Print Network [OSTI]

We find that the gas of IIA strings undergoes a phase transition into a gas of IIB strings at the self-dual temperature. A gas of free heterotic strings undergoes a Kosterlitz-Thouless duality transition with positive free energy and positive specific heat but vanishing internal energy at criticality. We examine the consequences of requiring a tachyon-free thermal string spectrum. We show that in the absence of Ramond-Ramond fluxes the IIA and IIB string ensembles are thermodynamically ill-defined. The 10D heterotic superstrings have nonabelian gauge fields and in the presence of a temperature dependent Wilson line background are found to share a stable and tachyon-free ground state at all temperatures starting from zero with gauge group SO(16)xSO(16). The internal energy of the heterotic string is a monotonically increasing function of temperature with a stable and supersymmetric zero temperature limit. Our results point to the necessity of gauge fields in a viable weakly coupled superstring theory. Note Added (Sep 2005).

Shyamoli Chaudhuri

2005-09-12T23:59:59.000Z

403

Finite temperature topological order in 2D topological color codes  

E-Print Network [OSTI]

In this work the topological order at finite temperature in two-dimensional color code is studied. The topological entropy is used to measure the behavior of the topological order. Topological order in color code arises from the colored string-net structures. By imposing the hard constrained limit the exact solution of the entanglement entropy becomes possible. For finite size systems, by raising the temperature, one type of string-net structure is thermalized and the associative topological entropy vanishes. In the thermodynamic limit the underlying topological order is fragile even at very low temperatures. Taking first the thermodynamic limit and then the zero-temperature limit and vice versa does not commute, and their difference is related only to the topology of regions. The contribution of the colors and symmetry of the model in the topological entropy is also discussed. It is shown how the gauge symmetry of the color code underlies the topological entropy.

Mehdi Kargarian

2009-07-19T23:59:59.000Z

404

Chiral dynamics in the low-temperature phase of QCD  

E-Print Network [OSTI]

We investigate the low-temperature phase of QCD and the crossover region with two light flavors of quarks. The chiral expansion around the point $(T, m_q = 0)$ in the temperature vs. quark-mass plane indicates that a sharp real-time excitation exists with the quantum numbers of the pion. We determine its dispersion relation and test the applicability of the chiral expansion. The time-dependent correlators are also analyzed using the Maximum Entropy Method (MEM), yielding consistent results. Finally, we test the predictions of ordinary chiral perturbation theory around the point $(T = 0, m_q = 0)$ for the temperature dependence of static observables. Around the crossover temperature, we find that all quantities considered depend only mildly on the quark mass in the considered range 8MeV $\\leq \\bar{m}^{\\bar{\\text{MS}}} \\leq$ 15MeV.

Bastian B. Brandt; Anthony Francis; Harvey B. Meyer; Daniel Robaina

2014-10-22T23:59:59.000Z

405

General relativity and experiment  

E-Print Network [OSTI]

The confrontation between Einstein's theory of gravitation and experiment is summarized. Although all current experimental data are compatible with general relativity, the importance of pursuing the quest for possible deviations from Einstein's theory is emphasized.

T. Damour

1994-12-08T23:59:59.000Z

406

Recursive relational urban design  

E-Print Network [OSTI]

This thesis proposes a methodology for the act of urban design that is recursive and centered around explicit relational operations, enabled by taking advantage of computation and parametric techniques. It contains iterative ...

Hillman, Dessen

2014-01-01T23:59:59.000Z

407

de Sitter special relativity  

E-Print Network [OSTI]

A special relativity based on the de Sitter group is introduced, which is the theory that might hold up in the presence of a non-vanishing cosmological constant. Like ordinary special relativity, it retains the quotient character of spacetime, and a notion of homogeneity. As a consequence, the underlying spacetime will be a de Sitter spacetime, whose associated kinematics will differ from that of ordinary special relativity. The corresponding modified notions of energy and momentum are obtained, and the exact relationship between them, which is invariant under a re-scaling of the involved quantities, explicitly exhibited. Since the de Sitter group can be considered a particular deformation of the Poincar\\'e group, this theory turns out to be a specific kind of deformed (or doubly) special relativity. Some experimental consequences, as well as the causal structure of spacetime--modified by the presence of the de Sitter horizon--are briefly discussed.

R. Aldrovandi; J. P. Beltran Almeida; J. G. Pereira

2007-02-08T23:59:59.000Z

408

Mechanical instability at finite temperature  

E-Print Network [OSTI]

Many physical systems including lattices near structural phase transitions, glasses, jammed solids, and bio-polymer gels have coordination numbers that place them at the edge of mechanical instability. Their properties are determined by an interplay between soft mechanical modes and thermal fluctuations. In this paper we investigate a simple square-lattice model with a $\\phi^4$ potential between next-nearest-neighbor sites whose quadratic coefficient $\\kappa$ can be tuned from positive negative. We show that its zero-temperature ground state for $\\kappa power-law behavior of the shear modulus as a function of temperature. We expect our study to provide a general framework for the study of finite-temperature mechanical and phase behavior of other systems with a large number of floppy modes.

Xiaoming Mao; Anton Souslov; Carlos I. Mendoza; T. C. Lubensky

2014-07-08T23:59:59.000Z

409

High temperature Seebeck coefficient metrology  

SciTech Connect (OSTI)

We present an overview of the challenges and practices of thermoelectric metrology on bulk materials at high temperature (300 to 1300 K). The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential property measurement for evaluating the potential performance of novel thermoelectric materials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at high temperature. This has led to the implementation of nonideal practices that have further complicated the confirmation of reported high ZT materials. To ensure meaningful interlaboratory comparison of data, thermoelectric measurements must be reliable, accurate, and consistent. This article will summarize and compare the relevant measurement techniques and apparatus designs required to effectively manage uncertainty, while also providing a reference resource of previous advances in high temperature thermoelectric metrology.

Martin, J. [Materials Science and Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Tritt, T. [Department of Physics and Astronomy, Clemson University, Clemson, South Carolina 29634 (United States); Uher, C. [Department of Physics, University of Michigan, Ann Arbor, Michigan 48109 (United States)

2010-12-15T23:59:59.000Z

410

High temperature Seebeck coefficient metrology  

SciTech Connect (OSTI)

We present an overview of the challenges and practices of thermoelectric metrology on bulk materials at high temperature (300 to 1300 K). The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential propertymeasurement for evaluating the potential performance of novel thermoelectricmaterials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at high temperature. This has led to the implementation of nonideal practices that have further complicated the confirmation of reported high ZT materials. To ensure meaningful interlaboratory comparison of data, thermoelectricmeasurements must be reliable, accurate, and consistent. This article will summarize and compare the relevant measurement techniques and apparatus designs required to effectively manage uncertainty, while also providing a reference resource of previous advances in high temperature thermoelectric metrology.

Martin, J.; Tritt, T.; Uher, Ctirad

2010-01-01T23:59:59.000Z

411

Using electrical resistance tomography to map subsurface temperatures  

DOE Patents [OSTI]

A method is provided for measuring subsurface soil or rock temperatures remotely using electrical resistivity tomography (ERT). Electrical resistivity measurements are made using electrodes implanted in boreholes driven into the soil and/or at the ground surface. The measurements are repeated as some process changes the temperatures of the soil mass/rock mass. Tomographs of electrical resistivity are calculated based on the measurements using Poisson's equation. Changes in the soil/rock resistivity can be related to changes in soil/rock temperatures when: (1) the electrical conductivity of the fluid trapped in the soil's pore space is low, (2) the soil/rock has a high cation exchange capacity and (3) the temperature changes are sufficiently high. When these three conditions exist the resistivity changes observed in the ERT tomographs can be directly attributed to changes in soil/rock temperatures. This method provides a way of mapping temperature changes in subsurface soils remotely. Distances over which the ERT method can be used to monitor changes in soil temperature range from tens to hundreds of meters from the electrode locations. 1 fig.

Ramirez, A.L.; Chesnut, D.A.; Daily, W.D.

1994-09-13T23:59:59.000Z

412

Using electrical resistance tomography to map subsurface temperatures  

DOE Patents [OSTI]

A method is provided for measuring subsurface soil or rock temperatures remotely using electrical resistivity tomography (ERT). Electrical resistivity measurements are made using electrodes implanted in boreholes driven into the soil and/or at the ground surface. The measurements are repeated as some process changes the temperatures of the soil mass/rock mass. Tomographs of electrical resistivity are calculated based on the measurements using Poisson's equation. Changes in the soil/rock resistivity can be related to changes in soil/rock temperatures when: (1) the electrical conductivity of the fluid trapped in the soil's pore space is low, (2) the soil/rock has a high cation exchange capacity and (3) the temperature changes are sufficiently high. When these three conditions exist the resistivity changes observed in the ERT tomographs can be directly attributed to changes in soil/rock temperatures. This method provides a way of mapping temperature changes in subsurface soils remotely. Distances over which the ERT method can be used to monitor changes in soil temperature range from tens to hundreds of meters from the electrode locations.

Ramirez, Abelardo L. (Pleasanton, CA); Chesnut, Dwayne A. (San Francisco, CA); Daily, William D. (Livermore, CA)

1994-01-01T23:59:59.000Z

413

Temperature Resistant Optimal Ratchet Transport  

E-Print Network [OSTI]

Stable periodic structures containing optimal ratchet transport, recently found in the parameter space dissipation versus ratchet parameter [PRL 106, 234101 (2011)], are shown to be resistant to reasonable temperatures, reinforcing the expectation that they are essential to explain the optimal ratchet transport in nature. Critical temperatures for their destruction, valid from the overdamping to close to the conservative limits, are obtained numerically and shown to be connected to the current efficiency, given here analytically. Results are demonstrated for a discrete ratchet model and generalized to the Langevin equation with an additional external oscillating force.

Cesar Manchein; Alan Celestino; Marcus W Beims

2012-11-12T23:59:59.000Z

414

Crystal face temperature determination means  

DOE Patents [OSTI]

An optically transparent furnace having a detection apparatus with a pedestal enclosed in an evacuated ampule for growing a crystal thereon is disclosed. Temperature differential is provided by a source heater, a base heater and a cold finger such that material migrates from a polycrystalline source material to grow the crystal. A quartz halogen lamp projects a collimated beam onto the crystal and a reflected beam is analyzed by a double monochromator and photomultiplier detection spectrometer and the detected peak position in the reflected energy spectrum of the reflected beam is interpreted to determine surface temperature of the crystal. 3 figs.

Nason, D.O.; Burger, A.

1994-11-22T23:59:59.000Z

415

High temperature superconductor current leads  

DOE Patents [OSTI]

An electrical lead is disclosed having one end for connection to an apparatus in a cryogenic environment and the other end for connection to an apparatus outside the cryogenic environment. The electrical lead includes a high temperature superconductor wire and an electrically conductive material distributed therein, where the conductive material is present at the one end of the lead at a concentration in the range of from 0 to about 3% by volume, and at the other end of the lead at a concentration of less than about 20% by volume. Various embodiments are shown for groups of high temperature superconductor wires and sheaths. 9 figs.

Hull, J.R.; Poeppel, R.B.

1995-06-20T23:59:59.000Z

416

RFID tag antenna based temperature sensing  

E-Print Network [OSTI]

Temperature monitoring is important in a number of fields, particularly cold supply chain applications. Most commercial wireless temperature sensors consist of transceivers, memory and batteries to maintain a temperature ...

Bhattacharyya, Rahul

417

High-Temperature Thermoelectric Materials Characterization for...  

Broader source: Energy.gov (indexed) [DOE]

High-Temperature Thermoelectric Materials Characterization for Automotive Waste Heat Recovery: Success Stories from the High Temperature Materials Laboratory (HTML) User Program...

418

High Temperature Thermoelectric Materials Characterization for...  

Broader source: Energy.gov (indexed) [DOE]

High Temperature Thermoelectric Materials Characterization for Automotive Waste Heat Recovery: Success Stories from the High Temperature Materials Laboratory (HTML) User Program...

419

Acid Doped Membranes for High Temperature PEMFC  

Broader source: Energy.gov [DOE]

Presentation on Acid Doped Membranes for High Temperature PEMFC to the High Temperature Membrane Working Group, May 25, 2004 in Philadelphia, PA.

420

Nanostructured High Temperature Bulk Thermoelectric Energy Conversion...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

High Temperature Bulk Thermoelectric Energy Conversion for Efficient Waste Heat Recovery Nanostructured High Temperature Bulk Thermoelectric Energy Conversion for Efficient Waste...

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Susanville District Heating District Heating Low Temperature...  

Open Energy Info (EERE)

Susanville District Heating District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Susanville District Heating District Heating Low Temperature...

422

Litchfield Correctional Center District Heating Low Temperature...  

Open Energy Info (EERE)

Correctional Center District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Litchfield Correctional Center District Heating Low Temperature Geothermal...

423

Narrowband high temperature superconducting receiver for low frequency radio waves  

DOE Patents [OSTI]

An underground communicating device has a low-noise SQUID using high temperature superconductor components connected to detect a modulated external magnetic flux for outputting a voltage signal spectrum that is related to the varying magnetic flux. A narrow bandwidth filter may be used to select a portion of the voltage signal spectrum that is relatively free of power line noise to output a relatively low noise output signal when operating in a portion of the electromagnetic spectra where such power line noise exists. A demodulator outputs a communication signal, which may be an FM signal, indicative of a modulation on the modulated external magnetic flux.

Reagor, David W. (Los Alamos, NM)

2001-01-01T23:59:59.000Z

424

3, 771789, 2007 temperatures and  

E-Print Network [OSTI]

cooling and the onset of North American glaciation P. Huybers1 and P. Molnar2 1 Department of Earth that gradual cooling in the eastern tropical Pacific led to cooling of North America and the initiation affects North American temperature and ice-ablation. Assuming that the modern relationship holds5 over

Boyer, Edmond

425

High temperature lightweight foamed cements  

DOE Patents [OSTI]

Cement slurries are disclosed which are suitable for use in geothermal wells since they can withstand high temperatures and high pressures. The formulation consists of cement, silica flour, water, a retarder, a foaming agent, a foam stabilizer, and a reinforcing agent. A process for producing these cements is also disclosed. 3 figs.

Sugama, Toshifumi.

1989-10-03T23:59:59.000Z

426

High temperature synthetic cement retarder  

SciTech Connect (OSTI)

A synthetic cement retarder which provides excellent retardation and compressive strength development has been synthesized. The response properties and temperature ranges of the synthetic retarder far exceed those of commonly used retarders such as lignosulfonates. The chemical nature of the new retarder is discussed and compared to another synthetic retarder.

Eoff, L.S.; Buster, D.

1995-11-01T23:59:59.000Z

427

High temperature lightweight foamed cements  

DOE Patents [OSTI]

Cement slurries are disclosed which are suitable for use in geothermal wells since they can withstand high temperatures and high pressures. The formulation consists of cement, silica flour, water, a retarder, a foaming agent, a foam stabilizer, and a reinforcing agent. A process for producing these cements is also disclosed.

Sugama, Toshifumi (Mastic Beach, NY)

1989-01-01T23:59:59.000Z

428

HIGH TEMPERATURE GEOTHERMAL RESERVOIR ENGINEERING  

E-Print Network [OSTI]

on the Cerro P r i e t o Geothermal F i e l d , Mexicali,e C e r r o P r i e t o Geothermal F i e l d , Baja C a l i1979 HIGH TEMPERATURE GEOTHERMAL RESERVOIR ENGINEERING R.

Schroeder, R.C.

2009-01-01T23:59:59.000Z

429

EXPERIMENTAL DETERMINATION OF STEAM WATER RELATIVE PERMEABILITY RELATIONS  

E-Print Network [OSTI]

EXPERIMENTAL DETERMINATION OF STEAM WATER RELATIVE PERMEABILITY RELATIONS A REPORT SUBMITTED;Abstract A set of relative permeability relations for simultaneous ow of steam and water in porous media with saturation and pressure measurements. These relations show that the relative permeability for steam phase

Stanford University

430

Self-calibrated active pyrometer for furnace temperature measurements  

DOE Patents [OSTI]

Pyrometer with a probe beam superimposed on its field-of-view for furnace temperature measurements. The pyrometer includes a heterodyne millimeter/sub-millimeter-wave or microwave receiver including a millimeter/sub-millimeter-wave or microwave source for probing. The receiver is adapted to receive radiation from a surface whose temperature is to be measured. The radiation includes a surface emission portion and a surface reflection portion which includes the probe beam energy reflected from the surface. The surface emission portion is related to the surface temperature and the surface reflection portion is related to the emissivity of the surface. The simultaneous measurement of surface emissivity serves as a real time calibration of the temperature measurement. In an alternative embodiment, a translatable base plate and a visible laser beam allow slow mapping out of interference patterns and obtaining peak values therefor. The invention also includes a waveguide having a replaceable end portion, an insulating refractory sleeve and/or a source of inert gas flow. The pyrometer may be used in conjunction with a waveguide to form a system for temperature measurements in a furnace. The system may employ a chopper or alternatively, be constructed without a chopper. The system may also include an auxiliary reflector for surface emissivity measurements.

Woskov, Paul P. (Bedford, MA); Cohn, Daniel R. (Chestnuthill, MA); Titus, Charles H. (Newtown Square, PA); Surma, Jeffrey E. (Kennewick, WA)

1998-01-01T23:59:59.000Z

431

Thermodynamics Review and Relations  

E-Print Network [OSTI]

Thermodynamics Review and Relations Review · Gas filled piston Motivation Thermodynamics the efficiency of steam engine. Only macroscopic continues states of matter are con- sidered. Thermodynamics of thermodynamics is essential since it easily to statistical mechanics. Definitions and Convention Signs The sign

432

Class not > 1% relative  

E-Print Network [OSTI]

into the Gulf of Mexico (GOM). Knowledge of the composition of this crude oil is instrumental in determining its DWH Crude Neutrals & Bases Organic Acids DWH Crude Neutrals & Bases Organic Acids 20 40 60 800 20 40 Class not > 1% relative abundance Carbon Number DWH Crude Neutrals & Bases Organic Acids DWH Crude

Weston, Ken

433

Critical Temperature Associated to Symmetry Breaking of Klein--Gordon fields versus Condensation Temperature in a Weakly interacting Bose--Einstein Gas  

E-Print Network [OSTI]

We deduce the relation between the critical temperature associated to the symmetry breaking of scalar fields with one--loop correction potential immersed in a thermal bath and the condensation temperature of the aforementioned system, assuming a harmonic oscillator type potential. We show that these two temperatures are related through the \\emph{scale} associated to the system. In this aim, we infer the order of magnitude for the \\emph{scale} as a function of the corresponding healing length, in order to give a criterium to compare both temperatures. Additionally, we prove that the condensation temperature is independent of the thermal bath within the semiclassical approximation, for a positive coupling constant, assuming that the thermal bath contribution is the lowest energy associated to the system.

Elias Castellanos; Tonatiuh Matos

2012-07-09T23:59:59.000Z

434

Relation between quark-antiquark potential and quark-antiquark free energy in hadronic matter  

E-Print Network [OSTI]

We study the relation between the quark-antiquark potential and the quark-antiquark free energy in hadronic matter. While a temperature is over the critical temperature, the potential of a heavy quark and a heavy antiquark almost equals the free energy, otherwise the quark-antiquark potential is substantially larger than the quark-antiquark free energy. While a temperature is below the critical temperature, the quark-antiquark free energy can be taken as the quark-antiquark potential.

Zhen-Yu Shen; Xiao-Ming Xu

2014-06-19T23:59:59.000Z

435

Electronic-Structure of High-Temperature Superconductors  

E-Print Network [OSTI]

, and for the corresponding metal atoms in related high-temperature superconductors. These peaks should be observable in electron energy-loss spectroscopy's and 6nal-state photoemission spectrosco- py 20 The calculated valences d,n are again given in Table II. Notice... again neatly cancel in YBa2Cu307. In summary, we have calculated the electronic struc- tures of the most typical members of the two known classes of high-temperature superconductors. The present results, obtained with a simple tight-binding model...

RICHERT, BA; Allen, Roland E.

1988-01-01T23:59:59.000Z

436

Dynamics of the Cosmological Apparent Horizon: Surface Gravity & Temperature  

E-Print Network [OSTI]

In the context of thermodynamics applied to our cosmological apparent horizon, we explicit in greater details our previous work which established the Friedmann Equations from projection of Hayward's Unified First Law. In particular, we show that the dynamical Hayward-Kodama surface gravity is perfectly well-defined and is suitable for this derivation. We then relate this surface gravity to a physical notion of temperature, and show this has constant, positive sign for any kind of past-inner trapping horizons. Hopefully this will clarify the choice of temperature in a dynamical Friedmann-Lema\\^itre-Roberston-Walker spacetime.

Helou, Alexis

2015-01-01T23:59:59.000Z

437

Temperature and density extrapolations in canonical ensemble Monte Carlo simulations  

E-Print Network [OSTI]

We show how to use the multiple histogram method to combine canonical ensemble Monte Carlo simulations made at different temperatures and densities. The method can be applied to study systems of particles with arbitrary interaction potential and to compute the thermodynamic properties over a range of temperatures and densities. The calculation of the Helmholtz free energy relative to some thermodynamic reference state enables us to study phase coexistence properties. We test the method on the Lennard-Jones fluids for which many results are available.

A. L. Ferreira; M. A. Barroso

1999-06-14T23:59:59.000Z

438

Envelope calculations for a low temperature neutron star  

E-Print Network [OSTI]

with distance inward from the surface R for all three star models S, I and II at effective temperature Te = 10 K 34 Density-pressure dependence for the Model S star at different values of Te 35 Envelope calculation traces in the opacity-density plane... )] (20) Similarly a relation between p and T can be found 64v GN~ uH() a+1 1 a+1 ~a+ 3 r L k 4-b+aJ 0 (21) Inserting this back into the energy transport equation (13) gives the radial dependence of the temperature (22) (23) where R is the surface...

McCoy, Robert Paul

1976-01-01T23:59:59.000Z

439

Destruction mechanisms for formaldehyde in atmospheric temperature plasmas  

E-Print Network [OSTI]

,O) is a common pollutant of indoor air in residences and commercial buildings. The removal of CH,O from of a full accounting of the electron, ion, and neutral chemical kinetics in contaminated humid air. We find per million of CH,O in air/energy deposition). The elimination of the unwanted byproducts, CO and NO

Kushner, Mark

440

ACCURATE TEMPERATURE MEASUREMENTS IN A NATURALLY-ASPIRATED RADIATION SHIELD  

SciTech Connect (OSTI)

Experiments and calculations were conducted with a 0.13 mm fine wire thermocouple within a naturally-aspirated Gill radiation shield to assess and improve the accuracy of air temperature measurements without the use of mechanical aspiration, wind speed or radiation measurements. It was found that this thermocouple measured the air temperature with root-mean-square errors of 0.35 K within the Gill shield without correction. A linear temperature correction was evaluated based on the difference between the interior plate and thermocouple temperatures. This correction was found to be relatively insensitive to shield design and yielded an error of 0.16 K for combined day and night observations. The correction was reliable in the daytime when the wind speed usually exceeds 1 m s{sup -1} but occasionally performed poorly at night during very light winds. Inspection of the standard deviation in the thermocouple wire temperature identified these periods but did not unambiguously locate the most serious events. However, estimates of sensor accuracy during these periods is complicated by the much larger sampling volume of the mechanically-aspirated sensor compared with the naturally-aspirated sensor and the presence of significant near surface temperature gradients. The root-mean-square errors therefore are upper limits to the aspiration error since they include intrinsic sensor differences and intermittent volume sampling differences.

Kurzeja, R.

2009-09-09T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

AN ELECTRICAL OXYGEN-TEMPERATURE METER  

E-Print Network [OSTI]

426 AN ELECTRICAL OXYGEN-TEMPERATURE METER FOR FISHERY BIOLOGISTS SEP 2 1196: vuUiJo HIM. . SPECIAL and Wildlife, Daniel H. Janzen, Director AN ELECTRICAL OXYGEN-TEMPERATURE METER FOR FISHERY BIOLOGISTS -temperature meter 11 Maintenance and trouble -shooting 12 #12;AN ELECTRICAL OXYGEN-TEMPERATURE METER

442

High Temperature Heat Exchanger Project  

SciTech Connect (OSTI)

The UNLV Research Foundation assembled a research consortium for high temperature heat exchanger design and materials compatibility and performance comprised of university and private industry partners under the auspices of the US DOE-NE Nuclear Hydrogen Initiative in October 2003. The objectives of the consortium were to conduct investigations of candidate materials for high temperature heat exchanger componets in hydrogen production processes and design and perform prototypical testing of heat exchangers. The initial research of the consortium focused on the intermediate heat exchanger (located between the nuclear reactor and hydrogen production plan) and the components for the hydrogen iodine decomposition process and sulfuric acid decomposition process. These heat exchanger components were deemed the most challenging from a materials performance and compatibility perspective

Anthony E. Hechanova, Ph.D.

2008-09-30T23:59:59.000Z

443

Battery system with temperature sensors  

DOE Patents [OSTI]

A battery system includes a platform having an aperture formed therethrough, a flexible member having a generally planar configuration and extending across the aperture, wherein a portion of the flexible member is coextensive with the aperture, a cell provided adjacent the platform, and a sensor coupled to the flexible member and positioned proximate the cell. The sensor is configured to detect a temperature of the cell.

Wood, Steven J; Trester, Dale B

2014-02-04T23:59:59.000Z

444

High temperature turbine engine structure  

DOE Patents [OSTI]

A high temperature ceramic/metallic turbine engine includes a metallic housing which journals a rotor member of the turbine engine. A ceramic disk-like shroud portion of the engine is supported on the metallic housing portion and maintains a close running clearance with the rotor member. A ceramic spacer assembly maintains the close running clearance of the shroud portion and rotor member despite differential thermal movements between the shroud portion and metallic housing portion.

Carruthers, William D. (Mesa, AZ); Boyd, Gary L. (Tempe, AZ)

1993-01-01T23:59:59.000Z

445

High temperature turbine engine structure  

DOE Patents [OSTI]

A high temperature ceramic/metallic turbine engine includes a metallic housing which journals a rotor member of the turbine engine. A ceramic disk-like shroud portion of the engine is supported on the metallic housing portion and maintains a close running clearance with the rotor member. A ceramic spacer assembly maintains the close running clearance of the shroud portion and rotor member despite differential thermal movements between the shroud portion and metallic housing portion.

Carruthers, William D. (Mesa, AZ); Boyd, Gary L. (Tempe, AZ)

1992-01-01T23:59:59.000Z

446

High temperature turbine engine structure  

DOE Patents [OSTI]

A high temperature ceramic/metallic turbine engine includes a metallic housing which journals a rotor member of the turbine engine. A ceramic disk-like shroud portion of the engine is supported on the metallic housing portion and maintains a close running clearance with the rotor member. A ceramic spacer assembly maintains the close running clearance of the shroud portion and rotor member despite differential thermal movements between the shroud portion and metallic housing portion.

Carruthers, William D. (Mesa, AZ); Boyd, Gary L. (Tempe, AZ)

1994-01-01T23:59:59.000Z

447

Variable temperature semiconductor film deposition  

DOE Patents [OSTI]

A method of depositing a semiconductor material on a substrate is disclosed. The method sequentially comprises (a) providing the semiconductor material in a depositable state such as a vapor for deposition on the substrate; (b) depositing the semiconductor material on the substrate while heating the substrate to a first temperature sufficient to cause the semiconductor material to form a first film layer having a first grain size; (c) continually depositing the semiconductor material on the substrate while cooling the substrate to a second temperature sufficient to cause the semiconductor material to form a second film layer deposited on the first film layer and having a second grain size smaller than the first grain size; and (d) raising the substrate temperature, while either continuing or not continuing to deposit semiconductor material to form a third film layer, to thereby anneal the film layers into a single layer having favorable efficiency characteristics in photovoltaic applications. A preferred semiconductor material is cadmium telluride deposited on a glass/tin oxide substrate already having thereon a film layer of cadmium sulfide.

Li, X.; Sheldon, P.

1998-01-27T23:59:59.000Z

448

NSTX High Temperature Sensor Systems  

SciTech Connect (OSTI)

The design of the more than 300 in-vessel sensor systems for the National Spherical Torus Experiment (NSTX) has encountered several challenging fusion reactor diagnostic issues involving high temperatures and space constraints. This has resulted in unique miniature, high temperature in-vessel sensor systems mounted in small spaces behind plasma facing armor tiles, and they are prototypical of possible high power reactor first-wall applications. In the Center Stack, Divertor, Passive Plate, and vessel wall regions, the small magnetic sensors, large magnetic sensors, flux loops, Rogowski Coils, thermocouples, and Langmuir Probes are qualified for 600 degrees C operation. This rating will accommodate both peak rear-face graphite tile temperatures during operations and the 350 degrees C bake-out conditions. Similar sensor systems including flux loops, on other vacuum vessel regions are qualified for 350 degrees C operation. Cabling from the sensors embedded in the graphite tiles follows narrow routes to exit the vessel. The detailed sensor design and installation methods of these diagnostic systems developed for high-powered ST operation are discussed.

B.McCormack; H.W. Kugel; P. Goranson; R. Kaita; et al

1999-11-01T23:59:59.000Z

449

Hauptmann's Relation To Christianity  

E-Print Network [OSTI]

KU ScholarWorks | The University of Kansas Pre-1923 Dissertations and Theses Collection Hauptmann’s Relation To Christianity 1914 by Irene May Garrett This work was digitized by the Scholarly Communications program staff in the KU Libraries... S T I A N I T Y . »y Irene May Garrett, A thesis submitted to the department of German of the University of Kansas in partial fullfilment of the requirements for the Master's Degree. May 15, 1914. Bibliography. Biography. Schlenther, Paul...

Garrett, Irene May

1914-05-15T23:59:59.000Z

450

ARM - Related Links  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUC :ProductsSCM Forcing Data DerivedInstruments Related Links

451

Quantifying Temperature Effects on Fall Chinook Salmon  

SciTech Connect (OSTI)

The motivation for this study was to recommend relationships for use in a model of San Joaquin fall Chinook salmon. This report reviews literature pertaining to relationships between water temperature and fall Chinook salmon. The report is organized into three sections that deal with temperature effects on development and timing of freshwater life stages, temperature effects on incubation survival for eggs and alevin, and temperature effects on juvenile survival. Recommendations are made for modeling temperature influences for all three life stages.

Jager, Yetta [ORNL

2011-11-01T23:59:59.000Z

452

A Constitutive Model for the Mechanical Behavior of Single Crystal Silicon at Elevated Temperature  

E-Print Network [OSTI]

Silicon in single crystal form has been the material of choice for the first demonstration of the MIT microengine project. However, because it has a relatively low melting temperature, silicon is not an ideal material for ...

Moon, H.-S.

453

Soil organic matter stability and the temperature sensitivity of soil respiration   

E-Print Network [OSTI]

Soil respiration is an important source of atmospheric CO2, with the potential for large positive feedbacks with global warming. The size of these feedbacks will depend on the relative sensitivity to temperature of very ...

Burns, Nancy Rosalind

2012-11-29T23:59:59.000Z

454

Thermodynamics of system with density- and/or temperature-dependent mass particles  

E-Print Network [OSTI]

The thermodynamics with medium effects expressed by the dispersion relation of the temperature and density dependent particle mass is studied. Many previous treatments have been reviewed. A new thermodynamical treatment based on the equilibrium state is suggested. Employing the quark mass density- and temperature-dependent model, the discrepancies between our treatment and others are addressed.

Shaoyu Yin; Ru-Keng Su

2007-04-27T23:59:59.000Z

455

Simulation and inversion of borehole temperature profiles in surrogate climates: Spatial distribution and surface coupling  

E-Print Network [OSTI]

simulations with the state-of-the-art ECHO-g model has been used to simulate underground temperature of the ECHO-g model to show that SAT-GST variations were closely related at low frequencies, suggesting-conduction forward model is driven by surface temperature time series provided with the ECHO-g integra- tions

Beltrami, Hugo

456

Hypothetical Thermodynamic Properties: The Boiling and Critical Temperatures of Polyethylene and Polytetrafluoroethylene  

E-Print Network [OSTI]

Hypothetical Thermodynamic Properties: The Boiling and Critical Temperatures of Polyethylene value asymptotically approaches TB() ) (1217 ( 246) K for series related to polyethylene by the melting temperature of polyethylene.4,5 In this article, the question of whether the normal boiling tem

Chickos, James S.

457

EFFECTS OF WATER AND TEMPERATURE John R. Jones, Merrill R. Kaufmann, and E. Arlo Richardson  

E-Print Network [OSTI]

EFFECTS OF WATER AND TEMPERATURE John R. Jones, Merrill R. Kaufmann, and E. Arlo Richardson not tolerate sustained high temperatures, or semiarid or even dry, subhumid conditions. Much can be inferred streams in relatively hot deserts. This indicates intolerance of high temper- ature effects-either direct

458

Research Results from A Few Alternate Methods of Interior Duct Systems in Factory Built Housing Located In the Hot Humid Climate  

E-Print Network [OSTI]

The U.S. Department of Energy’s (DOE) Building America1 Industrialized Housing Partnership (BAIHP) has collaborated with two of its industry partners to work on a portion of the project that relates to the construction and evaluation of prototype...

Moyer, N.; Stroer, D.; Hoak, D.; McIlvaine, J.; Chandra, S.

459

9 Cr-- 1 Mo steel material for high temperature application  

DOE Patents [OSTI]

One or more embodiments relates to a high-temperature, titanium alloyed, 9 Cr-1 Mo steel exhibiting improved creep strength and oxidation resistance at service temperatures up to 650.degree. C. The 9 Cr-1 Mo steel has a tempered martensite microstructure and is comprised of both large (0.5-3 .mu.m) primary titanium carbides and small (5-50 nm) secondary titanium carbides in a ratio of. from about 1:1.5 to about 1.5:1. The 9 Cr-1 Mo steel may be fabricated using exemplary austenizing, rapid cooling, and tempering steps without subsequent hot working requirements. The 9 Cr-1 Mo steel exhibits improvements in total mass gain, yield strength, and time-to-rupture over ASTM P91 and ASTM P92 at the temperature and time conditions examined.

Jablonski, Paul D; Alman, David; Dogan, Omer; Holcomb, Gordon; Cowen, Christopher

2012-11-27T23:59:59.000Z

460

Analytic behavior of the QED polarizability function at finite temperature  

E-Print Network [OSTI]

We revisit the analytical properties of the static quasi-photon polarizability function for an electron gas at finite temperature, in connection with the existence of Friedel oscillations in the potential created by an impurity. In contrast with the zero temperature case, where the polarizability is an analytical function, except for the two branch cuts which are responsible for Friedel oscillations, at finite temperature the corresponding function is not analytical, in spite of becoming continuous everywhere on the complex plane. This effect produces, as a result, the survival of the oscillatory behavior of the potential. We calculate the potential at large distances, and relate the calculation to the non-analytical properties of the polarizability.

A. Bernal; A. Perez

2011-01-20T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Predicted Impacts of Proton Temperature Anisotropy on Solar Wind Turbulence  

E-Print Network [OSTI]

Particle velocity distributions measured in the weakly collisional solar wind are frequently found to be non-Maxwellian, but how these non-Maxwellian distributions impact the physics of plasma turbulence in the solar wind remains unanswered. Using numerical solutions of the linear dispersion relation for a collisionless plasma with a bi-Maxwellian proton velocity distribution, we present a unified framework for the four proton temperature anisotropy instabilities, identifying the associated stable eigenmodes, highlighting the unstable region of wavevector space, and presenting the properties of the growing eigenfunctions. Based on physical intuition gained from this framework, we address how the proton temperature anisotropy impacts the nonlinear dynamics of the \\Alfvenic fluctuations underlying the dominant cascade of energy from large to small scales and how the fluctuations driven by proton temperature anisotropy instabilities interact nonlinearly with each other and with the fluctuations of the large-scal...

Klein, Kristopher G

2015-01-01T23:59:59.000Z

462

Chiral dynamics in the low-temperature phase of QCD  

E-Print Network [OSTI]

We investigate the low-temperature phase of QCD and the crossover region with two light flavors of quarks. The chiral expansion around the point $(T,m=0)$ in the temperature vs. quark-mass plane indicates that a sharp real-time excitation exists with the quantum numbers of the pion. An exact sum rule is derived for the thermal modification of the spectral function associated with the axial charge density; the (dominant) pion pole contribution obeys the sum rule. We determine the two parameters of the pion dispersion relation using lattice QCD simulations and test the applicability of the chiral expansion. The time-dependent correlators are also analyzed using the Maximum Entropy Method, yielding consistent results. Finally, we test the predictions of the chiral expansion around the point $(T=0,m=0)$ for the temperature dependence of static observables.

Bastian B. Brandt; Anthony Francis; Harvey B. Meyer; Daniel Robaina

2014-06-21T23:59:59.000Z

463

Geothermal: Related Links  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation ProposedUsingFun with Big Sky Learning FunNeuTel2011Programmatic ReportsContactRelated Links

464

Fermilab Today - Related Content  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-Series toESnet4:Epitaxial ThinFORFALL NEWSFemtosecondSystemsthisGuidelinesRelated

465

The Characterization of Scintillator Performance at Temperatures up to 400 Degrees Centigrade  

SciTech Connect (OSTI)

The logging and characterization of geothermal wells requires improved scintillator systems that are capable of operation at temperatures significantly above those commonly encountered in the logging of most conventional oil and gas wells (e.g., temperatures nominally in the range of up to 150oC.) Unfortunately, most of the existing data on the performance of scintillators for radiation detection at elevated temperatures is fragmentary, uncorrelated, and generally limited to relatively low temperatures in most cases to temperatures well below 200oC. We have designed a system for characterizing scintillator performance at temperatures extending up to 400oC under inert atmospheric conditions, and this system is applied here to the determination of scintillator performance at elevated temperatures for a wide range of scintillators including, among others: bismuth germanate, cadmium tungstate, cesium iodide, cesium iodide (Tl), cesium iodide (Na), sodium iodide, sodium iodide (Tl), lutetium oxy-orthosilicate (Ce), zinc tungstate, yttrium aluminum perovskite (Ce), yttrium aluminum garnet (Ce), lutetium aluminum perovskite (Ce), and barium fluoride, strontium iodide(Eu). The results of these high-temperature scintillator performance tests are described in detail here. Comparisons of the relative elevated-temperature properties of the various scintillator materials have resulted in the identification of promising scintillator candidates for high-temperature use in geothermal and fossil-fuel well environments.

Boatner, Lynn A [ORNL; Neal, John S [ORNL; Kolopus, James A [ORNL; Ramey, Joanne Oxendine [ORNL; Akkurt, Hatice [ORNL

2013-01-01T23:59:59.000Z

466

Steam-Water Relative Permeability  

Energy Savers [EERE]

Separation and Recovery of Rare Earth Elements from Low Temperature Geothermal Water 500,000 64,061 Lawrence Berkeley National Laboratory (LBNL) Engineering Thermophilic...

467

Method and apparatus for optical temperature measurement  

DOE Patents [OSTI]

A temperature probe and a method for using said probe for temperature measurements based on changes in light absorption by the probe are disclosed. The probe comprises a first and a second optical fiber that carry light to and from the probe, and a temperature sensor material, the absorbance of which changes with temperature, through which the light is directed. Light is directed through the first optical fiber, passes through the temperature sensor material, and is transmitted by a second optical fiber from the material to a detector. Temperature-dependent and temperature-independent factors are derived from measurements of the transmitted light intensity. For each sensor material, the temperature T is a function of the ratio, R, of these factors. The temperature function f(R) is found by applying standard data analysis techniques to plots of T versus R at a series of known temperatures. For a sensor having a known temperature function f(R) and known characteristic and temperature-dependent factors, the temperature can be computed from a measurement of R. Suitable sensor materials include neodymium-doped borosilicate glass, accurate to [+-]0.5 C over an operating temperature range of about [minus]196 C to 400 C; and a mixture of D[sub 2]O and H[sub 2]O, accurate to [+-]0.1 C over an operating range of about 5 C to 90 C. 13 figs.

O'Rourke, P.E.; Livingston, R.R.; Prather, W.S.

1994-09-20T23:59:59.000Z

468

Method and apparatus for optical temperature measurement  

DOE Patents [OSTI]

A temperature probe and a method for using said probe for temperature measurements based on changes in light absorption by the probe. The probe comprises a first and a second optical fiber that carry light to and from the probe, and a temperature sensor material, the absorbance of which changes with temperature, through which the light is directed. Light is directed through the first optical fiber, passes through the temperature sensor material, and is transmitted by a second optical fiber from the material to a detector. Temperature-dependent and temperature-independent factors are derived from measurements of the transmitted light intensity. For each sensor material, the temperature T is a function of the ratio, R, of these factors. The temperature function f(R) is found by applying standard data analysis techniques to plots of T versus R at a series of known temperatures. For a sensor having a known temperature function f(R) and known characteristic and temperature-dependent factors, the temperature can be computed from a measurement of R. Suitable sensor materials include neodymium-doped boresilicate glass, accurate to .+-.0.5.degree. C. over an operating temperature range of about -196.degree. C. to 400.degree. C.; and a mixture of D.sub.2 O and H.sub.2 O, accurate to .+-.0.1.degree. C. over an operating range of about 5.degree. C. to 90.degree. C.

O'Rourke, Patrick E. (Martinez, GA); Livingston, Ronald R. (Aiken, SC); Prather, William S. (Augusta, GA)

1994-01-01T23:59:59.000Z

469

Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data (Revised)  

SciTech Connect (OSTI)

This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February 2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution, and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.

Parker, D.; Sherwin, J.

2012-10-01T23:59:59.000Z

470

TECHNICAL BASIS FOR DOE STANDARD 3013 EQUIVALENCY SUPPORTING REDUCED TEMPERATURE STABILIZATION OF OXALATE-DERIVED PLUTONIUM OXIDE PRODUCED BY THE HB-LINE FACILITY AT SAVANNAH RIVER SITE  

SciTech Connect (OSTI)

The HB-Line (HBL) facility at the Savannah River Site (SRS) is designed to produce high-purity plutonium dioxide (PuO{sub 2}) which is suitable for future use in production of Mixed Oxide (MOX) fuel. The MOX Fuel Fabrication Facility (MFFF) requires PuO{sub 2} feed to be packaged per the U.S. Department of Energy (DOE) Standard 3013 (DOE-STD-3013) to comply with the facility's safety basis. The stabilization conditions imposed by DOE-STD-3013 for PuO{sub 2} (i.e., 950 C for 2 hours) preclude use of the HBL PuO{sub 2} in direct fuel fabrication and reduce the value of the HBL product as MFFF feedstock. Consequently, HBL initiated a technical evaluation to define acceptable operating conditions for production of high-purity PuO{sub 2} that fulfills the DOE-STD-3013 criteria for safe storage. The purpose of this document is to demonstrate that within the defined operating conditions, the HBL process will be equivalent for meeting the requirements of the DOE-STD-3013 stabilization process for plutonium-bearing materials from the DOE complex. The proposed 3013 equivalency reduces the prescribed stabilization temperature for high-purity PuO{sub 2} from oxalate precipitation processes from 950 C to 640 C and places a limit of 60% on the relative humidity (RH) at the lowest material temperature. The equivalency is limited to material produced using the HBL established flow sheet, for example, nitric acid anion exchange and Pu(IV) direct strike oxalate precipitation with stabilization at a minimum temperature of 640 C for four hours (h). The product purity must meet the MFFF acceptance criteria of 23,600 {micro}g/g Pu (i.e., 2.1 wt %) total impurities and chloride content less than 250 {micro}g/g of Pu. All other stabilization and packaging criteria identified by DOE-STD-3013-2012 or earlier revisions of the standard apply. Based on the evaluation of test data discussed in this document, the expert judgment of the authors supports packaging the HBL product under a 3013 equivalency. Under the defined process conditions and associated material specifications, the high-purity PuO{sub 2} produced in HBL presents no unique safety concerns for packaging or storage in the 3013 required configuration. The PuO{sub 2} produced using the HBL flow sheet conditions will have a higher specific surface area (SSA) than PuO{sub 2} stabilized at 950 C and, consequently, under identical conditions will adsorb more water from the atmosphere. The greatest challenge to HBL operators will be controlling moisture content below 0.5 wt %. However, even at the 0.5 wt % moisture limit, the maximum acceptable pressure of a stoichiometric mixture of hydrogen and oxygen in the 3013 container is greater than the maximum possible pressure for the HBL PuO{sub 2} product.

Duffey, J.; Livingston, R.; Berg, J.; Veirs, D.

2012-07-02T23:59:59.000Z

471

Magnetic insulation at finite temperatures  

SciTech Connect (OSTI)

A finite-temperature non-neutral plasma (FTNNP) theory of magnetically insulated (MI) electron flows in crossed-field vacuum devices is developed and applied in planar geometry. It is shown that, in contrast to the single type of MI flow predicted by traditional cold-plasma treatments, the nonlinear FTNNP equations admit five types of steady flow, of which three types are MI flows, including flows in which the electric field and/or the tangential velocity at the cathode may be zero or nonzero. It is also shown that finite-temperature Vlasov-Poisson treatments yield solutions for electron number densities and electrostatic potentials that are a subset of the FTNNP solutions. The algorithms that are used to solve the FTNNP equations numerically are discussed, and the numerical results are presented for several examples of the three types of MI flow. Results include prediction of the existence, boundaries, number density profiles, and other properties of sheaths of electrons in the anode-cathode gap.

Goedecke, G. H.; Davis, Brian T.; Chen, Chiping [Physics Department, New Mexico State University, Las Cruces, New Mexico 88003 and Raytheon Missile Systems, 1151 E. Hermans Road, Tucson, Arizona 85706 (United States); Intense Beam Theoretical Research Group, Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 and Raytheon Missile Systems, 1151 E. Hermans Road, Tucson, Arizona 85706 (United States)

2006-08-15T23:59:59.000Z

472

LOW TEMPERATURE CATHODE SUPPORTED ELECTROLYTES  

SciTech Connect (OSTI)

This report represents a summary of the work carried out on this project which started October 1999 and ended March 2003. A list of the publications resulting from the work are contained in Appendix A. The most significant achievements are: (1) Dense nanocrystalline zirconia and ceria films were obtained at temperatures < 400 C. (2) Nanocrystalline films of both ceria and zirconia were characterized. (3) We showed that under anodic conditions 0.5 to 1 micron thick nanocrystalline films of Sc doped zirconia have sufficient electronic conductivity to prevent them from being useful as an electrolyte. (4) We have developed a process by which dense 0.5 to 5 micron thick dense films of either YSZ or ceria can be deposited on sintered porous substrates which serve as either the cathode or anode at temperatures as low as 400 C. (5) The program has provided the research to produce two PhD thesis for students, one is now working in the solid oxide fuel cell field. (6) The results of the research have resulted in 69 papers published, 3 papers submitted or being prepared for publication, 50 oral presentations and 3 patent disclosures.

Harlan U. Anderson; Fatih Dogan; Vladimir Petrovsky

2003-03-31T23:59:59.000Z

473

Energy-related indoor environmental quality research: A priority agenda  

SciTech Connect (OSTI)

A multidisciplinary team of IEQ and energy researchers has defined a program of priority energy-related IEQ research. This paper describes the methods employed to develop the agenda, and 35 high priority research and development (R&D) project areas related to four broad goals: (1) identifying IEQ problems and opportunities; (2) developing and evaluating energy-efficient technologies for improving IEQ; (3) developing and evaluating energy-efficient practices for improving IEQ; and (4) encouraging or assisting the implementation of technologies or practices for improving IEQ. The identified R&D priorities reflect a strong need to benchmark IEQ conditions in small commercial buildings, schools, and residences. The R&D priorities also reflect the need to better understand how people are affected by IEQ conditions and by the related building characteristics and operation and maintenance practices. The associated research findings will provide a clearer definition of acceptable IEQ that is required to guide the development of technologies, practices, standards, and guidelines. Quantifying the effects of building characteristics and practices on IEQ conditions, in order to provide the basis for development of energy efficient and effective IEQ control measures, was also considered a priority. The development or advancement in a broad range of IEQ tools, technologies, and practices are also a major component of the priority research agenda. Consistent with the focus on ''energy-related'' research priorities, building ventilation and heating, ventilating and air conditioning (HVAC) systems and processes are very prominent in the agenda. Research related to moisture and microbiological problems, particularly within hot and humid climates, is also prominent within the agenda. The agenda tends to emphasize research on residences, small commercial buildings, and schools because these types of buildings have been underrepresented in prior research. Most of the research areas apply to both new construction and existing buildings. Nearly all of the recommended priority R&D project areas include tasks intended to facilitate the communication and implementation of the research results. In addition, the priority agenda includes several projects specifically designed to facilitate or stimulate the use of existing energy-efficient technologies and practices for improving IEQ. To assure that the research program continues to meet the needs of stakeholders and to facilitate the coordination of research among sponsors, the core team recommends an annual meeting attended by sponsors, a balanced group of stakeholders, and a selection of researchers implementing the agenda.

Fisk, W.J.; Brager, G.; Burge, H.; Cummings, J.; Levin, H.; Loftness, V.; Mendell, M.J.; Persily, A.; Taylor, S.; Zhang, J.S.

2002-08-01T23:59:59.000Z

474

Soil fungicides in relation to cotton seedling disease at various temperature levels  

E-Print Network [OSTI]

to obtain controlled spacing an4 4epth of seed ?hon ylanting, ~, , ~ 18 Xllnotration of seedling disease grades. Xi No evidence of diseases' energed 2 Sprouted' no e?L'donee of disease; no ssLergenoe. 5 Lesion less than three nao in length? 4i Lesion... of disease. 2, Emerged; lesion lees than three nn. long. ~Eaepgedj le&oh learn Qlall I%a ss, 10$$, gl aineb io the non proprietary nano ef sino ?thglene bi sdithiooarhanate. 4. Knerged~ sevorelF lesiono4, but not girdle4. 5? Energed~ dea4 or girdling...

Ranney, Carleton David

1955-01-01T23:59:59.000Z

475

The relation of octane number, compression ratio, and exhaust temperature in the gasoline engine  

E-Print Network [OSTI]

on the engine consisted of a battery, two induction coils, distributor, spark indicator and spark plug. One induction coil was connected to the spark indicator on which could be read the amount of spark advance or retardation, while the other was connected... into the spark plug circuit. Fuel was supplied to the engine by gravity flow through flexible and copper tubing, a ceramic filter, and a simple float type carburetor from a gallon tank mounted on platform scales, The scales were graduated in hundredths...

Jentsch, Donald George

1951-01-01T23:59:59.000Z

476

Fundamental studies of perovskite related oxide thin films for oxygen electrocatalysis at intermediate temperatures  

E-Print Network [OSTI]

Discovering highly active and stable catalysts for electrochemical energy conversion and storage is essential to envision a new generation of renewable energy applications. Mixed ionic and electronic conductors (MIECs) ...

Lee, Dongkyu, Ph. D. Massachusetts Institute of Technology

2014-01-01T23:59:59.000Z

477

Temperature and pressure dependences of the Copper-related Green Emission  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security AdministrationcontrollerNanocrystallineForeignTechnology-Selection-Process SignL.Ted Donat1 Soil Waterin

478

Comparison of DOE-2.1E with Energyplus and TRNSYS for Ground Coupled Residential Buildings in Hot anf Humid Climates Stage 4  

E-Print Network [OSTI]

. Deru, R. Henninger, H. Ribberink, J. Thornton, A. Wijsman, M. Witte, International Energy Agency Building Energy Simulation Test and Diagnostic Method (IEA BESTEST) In-Depth Diagnostic Cases for Ground Coupled Heat Transfer Related to Slab.... Deru, R. Judkoff, J.Neymark, Proposed IEA BESTEST Ground-Coupled Cases, Golden, Colorado, USA: National Renewable Energy Laboratory, In conjunction with International Energy Agency, Solar Heating and Cooling Programme Task 22, IEA Working Document...

Andolsun, S.; Culp, C.

2012-01-01T23:59:59.000Z

479

Corrosion resistant coatings suitable for elevated temperature application  

DOE Patents [OSTI]

The present invention relates to corrosion resistance coatings suitable for elevated temperature applications, which employ compositions of iron (Fe), chromium (Cr), nickel (Ni) and/or aluminum (Al). The compositions may be configured to regulate the diffusion of metals between a coating and a substrate, which may then influence coating performance, via the formation of an inter-diffusion barrier layer. The inter-diffusion barrier layer may comprise a face-centered cubic phase.

Chan, Kwai S. (San Antonio, TX); Cheruvu, Narayana Sastry (San Antonio, TX); Liang, Wuwei (Austin, TX)

2012-07-31T23:59:59.000Z

480

Probing the Temperature Profile of Energy Production in the Sun  

E-Print Network [OSTI]

The particle kinetic energies of pp fusion in the sun (Gamow Energy) produce small changes in the energies of pp solar neutrinos relative to those due only to exothermal energetics. Observation of this effect may be possible via the unique tools of the upcoming LENS solar neutrino detector. The temperature profile of energy production in the sun may thus be directly probed for the first time.

Christian Grieb; R. S. Raghavan

2006-09-04T23:59:59.000Z

Note: This page contains sample records for the topic "temperature relative humidity" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Thermostat Interface and Usability: A Survey  

E-Print Network [OSTI]

Remote control Control; controlling Feedback control Temperature control Measure humidity Upper limit of temperature Lower limit of temperature Cooling

Meier, Alan

2011-01-01T23:59:59.000Z

482

Low sintering temperature glass waste forms for sequestering radioactive iodine  

DOE Patents [OSTI]

Materials and methods of making low-sintering-temperature glass waste forms that sequester radioactive iodine in a strong and durable structure. First, the iodine is captured by an adsorbant, which forms an iodine-loaded material, e.g., AgI, AgI-zeolite, AgI-mordenite, Ag-silica aerogel, ZnI.sub.2, CuI, or Bi.sub.5O.sub.7I. Next, particles of the iodine-loaded material are mixed with powdered frits of low-sintering-temperature glasses (comprising various oxides of Si, B, Bi, Pb, and Zn), and then sintered at a relatively low temperature, ranging from 425.degree. C. to 550.degree. C. The sintering converts the mixed powders into a solid block of a glassy waste form, having low iodine leaching rates. The vitrified glassy waste form can contain as much as 60 wt % AgI. A preferred glass, having a sintering temperature of 500.degree. C. (below the silver iodide sublimation temperature of 500.degree. C.) was identified that contains oxides of boron, bismuth, and zinc, while containing essentially no lead or silicon.

Nenoff, Tina M.; Krumhansl, James L.; Garino, Terry J.; Ockwig, Nathan W.

2012-09-11T23:59:59.000Z

483

EFFECT OF MECHANICAL CONDITIONING ON THIN-LAYER DRYING OF ENERGY SORGHUM (Sorghum bicolor (L.) Moench)  

SciTech Connect (OSTI)

Cellulosic energy varieties of Sorghum bicolor (L.) Moench show promise as a bioenergy feedstock, however, high moisture content at the time of harvest results in unacceptable levels of degradation when stored in aerobic conditions. To safely store sorghum biomass for extended periods in baled format, the material must be dried to inhibit microbial growth. One possible solution is allowing the material to dry under natural in-field conditions. This study examines the differences in thin-layer drying rates of intact and conditioned sorghum under laboratory-controlled temperatures and relative humidity levels (20 degrees C and 30 degrees C from 40% to 85% relative humidity), and models experimental data using the Page’s Modified equation. The results demonstrate that conditioning drastically accelerates drying times. Relative humidity had a large impact on the time required to reach a safe storage moisture content for intact material (approximately 200 hours at 30 degrees C and 40% relative humidity and 400 hours at 30 degrees C and 70% relative humidity), but little to no impact on the thin-layer drying times of conditioned material (approximately 50 hours for all humidity levels < 70% at 30 degrees C). The drying equation parameters were influenced by temperature, relative humidity, initial moisture content, and material damage, allowing drying curves to be empirically predicted. The results of this study provide valuable information applicable to the agricultural community and to future research on drying simulation and management of energy sorghum.

Ian J. Bonner; Kevin L. Kenney

2012-10-01T23:59:59.000Z

484

Enhanced quantum coherence in graphene caused by Pd cluster deposition and its zero-temperature saturation  

E-Print Network [OSTI]

We report on the unexpected increase in the dephasing lengths of a graphene sheet caused by the deposition of Pd nanoclusters, as demonstrated by weak localization measurements. The dephasing lengths reached saturated values at low temperatures, which was essentially related to zero-temperature dephasing. The temperature-dependent dephasing was described by 1/(TlnT) and the saturated dephasing period was found to depend on {\\sigma}le, revealing disorder-induced zero-temperature dephasing in our defect-enriched graphene. Taken together with our theoretical calculations, we suggest that competition between surface scattering and charge transfer leads to the improvement of quantum coherence in cluster-decorated graphene.

Yuyuan Qin; Junhao Han; Guoping Guo; Zhaoguo Li; Yongping Du; You Song; Li Pi; Xuefeng Wang; Xiangang Wan; Wei Ning; Feng Miao; Xinran Wang; Zhe Qu; Jianfeng Zhou; Jianguo Wan; Min Han; Fengqi Song; Baigeng Wang; Guanghou Wang

2014-02-14T23:59:59.000Z

485

Possible Routes to Frictionless Transport of Electronic Fluids in High-Temperature Superconductors  

E-Print Network [OSTI]

Electric-field-driven transport of electronic fluids in metallic glasses as well as three-dimensional amorphous superconductors are investigated by using the verified approach which has been successfully adopted to study the critical transport of glassy solid helium in very low temperature environment. The critical temperatures related to the nearly frictionless transport of electronic fluids were found to be directly relevant to the superconducting temperature of amorphous superconductors after selecting specific activation energies. Our results imply that optimal shear-thinning is an effective way to reach high-temperature charged superfluidity or superconductivity.

Zotin K-H Chu

2009-12-23T23:59:59.000Z

486

Temperature Sensor Data Michael W. Bigrigg  

E-Print Network [OSTI]

in the room. Sensor networks can be used to identify larger trends in temperature which could be used to report energy usage, HVAC problems, computer failures based on high temperatures, and fire evacuation

Sadeh, Norman M.

487

Water Power Calculator Temperature and Analog Input/Output Module Ambient Temperature Testing  

SciTech Connect (OSTI)

Water Power Calculator Temperature and Analog input/output Module Ambient Temperature Testing A series of three ambient temperature tests were conducted for the Water Power Calculator development using the INL Calibration Laboratory’s Tenney Environmental Chamber. The ambient temperature test results demonstrate that the Moore Industries Temperature Input Modules, Analog Input Module and Analog Output Module, ambient temperature response meet or exceed the manufactures specifications

Mark D. McKay

2011-02-01T23:59:59.000Z

488

Carbon nanotube temperature and pressure sensors  

DOE Patents [OSTI]

The present invention, in one embodiment, provides a method of measuring pressure or temperature using a sensor including a sensor element composed of a plurality of carbon nanotubes. In one example, the resistance of the plurality of carbon nanotubes is measured in response to the application of temperature or pressure. The changes in resistance are then recorded and correlated to temperature or pressure. In one embodiment, the present invention provides for independent measurement of pressure or temperature using the sensors disclosed herein.

Ivanov, Ilia N; Geohegan, David Bruce

2013-10-29T23:59:59.000Z

489

Determining Outdoor CPV Cell Temperature: Preprint  

SciTech Connect (OSTI)

An accurate method is needed for determining cell temperature when measuring CPV modules outdoors. It has been suggested that cell temperature can be calculated though a procedure that shutters sunlight to the cells while measuring the transients in open-circuit voltage (Voc) and heat sink temperature. This paper documents application of this shutter procedure to multiple CPV modules at NREL. The challenges and limitations are presented along with an alternate approach to measuring CPV cell operating temperature.

Muller, M.; Deline, C.; Marion, B.; Kurtz, S.; Bosco, N.

2011-07-01T23:59:59.000Z

490

Agenda: High Temperature Membrane Working Group Meeting  

Broader source: Energy.gov [DOE]

Agenda for the High Temperature Membrane Working Group (HTMWG) meeting on May 18, 2009, in Arlington, Virginia

491

Corrosion Resistant Coatings for High Temperature Applications  

SciTech Connect (OSTI)

Efforts to increase efficiency of energy conversion devices have required their operation at ever higher temperatures. This will force the substitution of higher-temperature structural ceramics for lower temperature materials, largely metals. Yet, many of these ceramics will require protection from high temperature corrosion caused by combustion gases, atmospheric contaminants, or the operating medium. This paper discusses examples of the initial development of such coatings and materials for potential application in combustion, aluminum smelting, and other harsh environments.

Besman, T.M.; Cooley, K.M.; Haynes, J.A.; Lee, W.Y.; Vaubert, V.M.

1998-12-01T23:59:59.000Z

492

LOW TEMPERATURE CATHODE SUPPORTED ELECTROLYTES  

SciTech Connect (OSTI)

This project has three main goals: Thin Films Studies, Preparation of Graded Porous Substrates and Basic Electrical Characterization and Testing of Planar Single Cells. During this time period substantial progress has been made in developing low temperature deposition techniques to produce dense, nanocrystalline yttrium-stabilized zirconia films on both dense oxide and polymer substrates. Progress has been made in the preparation and characterization of thin electrolytes and porous LSM substrates. Both of these tasks are essentially on or ahead of schedule. In our proposal, we suggested that the ZrO{sub 2}/Sc system needed to be considered as a candidate as a thin electrolyte. This was because microcrystalline ZrO{sub 2}/Sc has a significantly higher ionic conductivity than YSZ, particularly at the lower temperatures. As a result, some 0.5 micron thick film of ZrO{sub 2}/16% Sc on an alumina substrate (grain size 20nm) was prepared and the electrical conductivity measured as a function of temperature and oxygen activity. The Sc doped ZrO{sub 2} certainly has a higher conductivity that either 20nm or 2400nm YSZ, however, electronic conductivity dominates the conductivity for oxygen activities below 10{sup -15}. Whereas for YSZ, electronic conductivity is not a problem until the oxygen activity decreases below 10{sup -25}. These initial results show that the ionic conductivity of 20nm YSZ and 20nm ZrO{sub 2}/16% Sc are essentially the same and the enhanced conductivity which is observed for Sc doping in microcrystalline specimens is not observed for the same composition when it is nanocrystalline. In addition they show that the electronic conductivity of Sc doped ZrO{sub 2} is at least two orders of magnitude higher than that observed for YSZ. The conclusion one reaches is that for 0.5 to 1 micron thick nanocrystalline films, Sc doping of ZrO{sub 2} has no benefits compared to YSZ. As a result, electrolyte films of ZrO{sub 2}/Sc should not be considered as candidates. However, they have the potential of being useful as an interface on the anode side of the electrolyte. NexTech has focused much of its effort during the past few months on establishing tape casting methods for porous LSM substrates. This work, performed under a separate DOE-funded program, involved tape casting formulations comprising LSM powders with bi-modal particle size distributions and fugitive pore forming additives. Sintered LSM substrates with porosities in the 30 to 40 vol% range, and pore sizes of 10 {approx} 20 microns have been prepared. In addition, tape casting formulations involving composite mixtures of LSM and Sm-doped ceria (SDC) have been evaluated. The LSM/SDC cathode substrates are expected to provide better performance at low temperatures. Characterization of these materials is currently underway.

Harlan U. Anderson

2000-03-31T23:59:59.000Z

493

LOW TEMPERATURE CATHODE SUPPORTED ELECTROLYTES  

SciTech Connect (OSTI)

This project has three main goals: Thin Films Studies, Preparation of Graded Porous Substrates and Basic Electrical Characterization and testing of Planar Single Cells. During this time period substantial progress has been made in developing low temperature deposition techniques to produce dense, nanocrystalline yttrium-stabilized zirconia films on both dense oxide and polymer substrates. Microstructural changes in unsupported nanocrystalline yttrium stabilized zirconia (ZrO{sub 2}:16%Y, or YSZ) thin films were examined as a function of temperature and annealing time in order to determine the grain growth exponent and the mechanisms of pinhole formation. Grain growth and pinhole formation were measured using high resolution transmission electron microscopy (HRTEM), normal imaging mode transmission electron microscopy (TEM), electron diffraction, and energy dispersive X-ray microanalysis (EDS). Grain growth was found to vary with a time exponent of about one half before pinhole formation and about one third after. Pinhole formation in 70 nm thick films occurred at temperatures near 600 C, corresponding to a grain size of about 15 nm, or a grain size to film thickness ration of approximately 0.25. The deposition of films on porous substrates is hampered by the penetration of the polymer precursor solution into the substrate whose pores as > 0.2 {micro}m, therefore much attention has to be paid to the development of porous colloidal oxide films onto surfaces. Thus during this line period we have been studying these films. Optical properties have proven to be an excellent way to study the quality of these nanoporous films. The influence of porosity and densification on optical properties of films on sapphire substrates that were prepared from water colloidal suspensions of small ({approx}5nm) particles of ceria was investigated. The colloidal ceria films have initially very porous structure (porosity about 50%) and densification starts at about 600 C accompanied by grain growth. The concurrence of these two processes makes it difficult to interpret the results of the optical spectrophotometry, but the combination of transmittance and reflectance measurements provides enough data to separate these two influences and to calculate the porosity, particle size and energy band gap separately. XRD, SEM, ellipsometry and mechanical profilometry were used to confirm the results obtained from the spectrophotometric measurements. All these methods gave results, which are in good agreement: the change in the porosity from 50% to 15% and the particle size increased from 5 to 65nm in the temperature region from 400 to 1000 C. An important result of the investigation is the fact that the main optical properties of the coating such as refractive index and band gap energy depend only on the porosity, but not on the grain size. The grain size influences the scattering properties of the coating, which allows the grain size to be estimated from optical measurements.

Harlan U. Anderson; Wayne Huebner; Igor Kosacki

2000-09-30T23:59:59.000Z

494

High temperature superconducting fault current limiter  

DOE Patents [OSTI]

A fault current limiter for an electrical circuit is disclosed. The fault current limiter includes a high temperature superconductor in the electrical circuit. The high temperature superconductor is cooled below its critical temperature to maintain the superconducting electrical properties during operation as the fault current limiter. 15 figs.