  1. The Temperature and Relative Humidity Control in Cushing Library

    E-Print Network [OSTI]

    Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D.; Bruner, H., Jr.

    2002-01-01T23:59:59.000Z

    Cushing Library located on TAMU campus is a special building, which needs precise temperature and relative humidity control, because it stores a number of rare collections and memorial books. There are five air-handling units (AHUs) serving...

  2. SRNL PHASE II SHELF LIFE STUDIES - SERIES 1 ROOM TEMPERATURE AND HIGH RELATIVE HUMIDITY

    SciTech Connect (OSTI)

    Mickalonis, J.; Duffey, J.

    2012-09-12T23:59:59.000Z

    The Savannah River National Laboratory (SRNL) Phase II, Series 1 shelf-life corrosion testing for the Department of Energy Standard 3013 container is presented and discussed in terms of the localized corrosion behavior of Type 304 stainless steel in contact with moist plutonium oxide and chloride salt mixtures and the potential impact to the 3013 inner container. This testing was designed to address the influence of temperature, salt composition, initial salt moisture, residual stress and type of oxide/salt contact on the relative humidity inside a 3013 container and the initiation and propagation of localized corrosion, especially stress corrosion cracking. The integrated plan is being conducted by Los Alamos National Laboratory and SRNL. SRNL is responsible for conducting a corrosion study in small scale vessels containing plutonium oxide and chloride salts under conditions of humidity, temperature and oxide/salt compositions both within the limits of 3013 storage conditions as well as beyond the 3013 storage requirements to identify margins for minimizing the initiation of stress corrosion cracking. These worst case conditions provide data that bound the material packaged in 3013 containers. Phase I of this testing was completed in 2010. The Phase II, Series 1 testing was performed to verify previous results from Phase I testing and extend our understanding about the initiation of stress corrosion cracking and pitting that occur in 304L under conditions of room temperature, high humidity, and a specific plutonium oxide/salt chemistry. These results will aid in bounding the safe storage conditions of plutonium oxides in 3013 containers. A substantial change in the testing was the addition of the capability to monitor relative humidity during test exposure. The results show that under conditions of high initial moisture ({approx}0.5 wt%) and room temperature stress corrosion cracking occurred in 304L teardrop coupons in contact with the oxide/salt mixture at times as short as 85 days. In all cases, the cracking appeared to be associated with pitting or localized general corrosion. Crack initiation at other sites, such as surface imperfections or inclusions, cannot be excluded. Cracks appear in most cases to initiate through an intergranular mode and transition to a transgranular mode.

  3. Lead Research and Development Activity for DOE's High Temperature, Low Relative Humidity Membrane Program (Topic 2)

    SciTech Connect (OSTI)

    James Fenton, PhD; Darlene Slattery, PhD; Nahid Mohajeri, PhD

    2012-09-05T23:59:59.000Z

    The Department of Energy’s High Temperature, Low Relative Humidity Membrane Program was begun in 2006 with the Florida Solar Energy Center (FSEC) as the lead organization. During the first three years of the program, FSEC was tasked with developing non-Nafion® proton exchange membranes with improved conductivity for fuel cells. Additionally, FSEC was responsible for developing protocols for the measurement of in-plane conductivity, providing conductivity measurements for the other funded teams, developing a method for through-plane conductivity and organizing and holding semiannual meetings of the High Temperature Membrane Working Group (HTMWG). The FSEC membrane research focused on the development of supported poly[perfluorosulfonic acid] (PFSA) – Teflon membranes and a hydrocarbon membrane, sulfonated poly(ether ether ketone). The fourth generation of the PFSA membrane (designated FSEC-4) came close to, but did not meet, the Go/No-Go milestone of 0.1 S/cm at 50% relative humidity at 120 °C. In-plane conductivity of membranes provided by the funded teams was measured and reported to the teams and DOE. Late in the third year of the program, DOE used this data and other factors to decide upon the teams to continue in the program. The teams that continued provided promising membranes to FSEC for development of membrane electrode assemblies (MEAs) that could be tested in an operating fuel cell. FSEC worked closely with each team to provide customized support. A logic flow chart was developed and discussed before MEA fabrication or any testing began. Of the five teams supported, by the end of the project, membranes from two of the teams were easily manufactured into MEAs and successfully characterized for performance. One of these teams exceeded performance targets, while the other requires further optimization. An additional team developed a membrane that shows great promise for significantly reducing membrane costs and increasing membrane lifetime.

  4. Modelling the influence of temperature and relative humidity on the time-dependent mechanical behaviour of a short glass fibre reinforced polyamide

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    . Introduction Carmakers are facing the challenge of reducing CO2 emis- sions, and are thus strongly interested. Both temperature and relative humidity are known to have an impact on mechanical properties strength of SGFR polyamides is highly sensitive to both temperature and relative humidity (Bernasconi et al

  5. Effect of Changes in Relative Humidity and Temperature on Ultrathin Chitosan Films

    E-Print Network [OSTI]

    Dutcher, John

    of infrared absorption measurements of chitosan films collected before and after heating indicate an increase neutralizing the films, they readily absorbed water in the presence of high humidity. Heating of the films in the degree of acetylation with heating. Collectively, these observations are consistent with the release

  6. ARM - Relative Humidity Calculations

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625govInstrumentstdmadap Documentation TDMADAP :ProductsVaisala CL51Instruments Related Links

  7. Adaptive GPC Structures for Temperature and Relative Humidity Control of a Nonlinear

    E-Print Network [OSTI]

    Boyer, Edmond

    units used in crop growth chambers are made up of heating and cooling system components used in greenhouses are ventilation, evaporative cooling, and composite systems. A simple way to reduce the difference between inside and outside air temperature is to improve ventilation. Natural ventilation uses

  8. Theoretical full power correction factors as related to changes in ambient temperature, pressure and absolute humidity for aircraft turbine engines

    E-Print Network [OSTI]

    Raphael, Michel Antoun

    1969-01-01T23:59:59.000Z

    IN AMBIENT TEMPERATURE, PRESSURF. AND ABSOLUTE HUMIDITY FOR AIRCRAFT TURBINE ENGINES (August 1969) Michael Antoun Raphael B. S. (Mechanical Engineering) Texas A&M University Directed by: Professor Stanley H, Lowy ABSTRACT Power losses in aircraft gas... rated at standard atmospheric conditions (i. e, ambient temperature 69 F 3'Fend atmospheric pressure 29. 92 in. Hg. dry) . Obviously this same turbine will not be exposed to such standard conditions; therefore we have a change in power directly...

  9. Group 3: Humidity, Temperature, and Voltage (Presentation)

    SciTech Connect (OSTI)

    Wohlgemuth, J.

    2013-05-01T23:59:59.000Z

    Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

  10. Group 3: Humidity, Temperature, and Voltage

    Broader source: Energy.gov [DOE]

    This PowerPoint presentation, focused on humidity, temperature and voltage testing, was originally presented by John Wohlgemuth at the NREL 2013 PV Module Reliability Workshop on Feb. 26-27, 2013 in Denver, CO. It summarizes the activities of a working group chartered to develop accelerated stress tests that can be used as comparative predictors of module life versus stresses associated with humidity, temperature and voltage.

  11. Group 3: Humidity, Temperature and Voltage (Presentation)

    SciTech Connect (OSTI)

    Wohlgemuth, J.

    2013-09-01T23:59:59.000Z

    This is a summary of the work of Group 3 of the International PV QA Task Force. Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

  12. Integrated Temperature and Humidity Control: A Unique Approach

    E-Print Network [OSTI]

    Shah, D. J.

    2000-01-01T23:59:59.000Z

    During hot and humid periods, a comfortable indoor environment can be attained only by controlling both the dry-bulb temperature and the humidity in the space. Conventional thermostats control the ON/OFF status of a cooling plant to maintain only...

  13. The effect of temperature and humidity on respirator fit 

    E-Print Network [OSTI]

    Niekerk, Gary

    1986-01-01T23:59:59.000Z

    THE EFFECT OF TEMPERATURE AND HUMIDITY ON RESPIRATOR FIT A Thesis by GARY NIEKERK Submitted to the Graduate College of Texas ASM University in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE August 1986 Maj... or Subject: Industr ial Hygiene THE EFFECT OF TEMPERATURE AND HUMIDITY ON RESPIRATOR FIT A Thesis by Gary Niekerk Approved as to style and content by: c . o n ( Chairman of Coami ttee) a . e non (Member) anie . ones (Member) e an . an (Head...

  14. Effects of Temperature and Humidity on Wilethane 44 Cure

    SciTech Connect (OSTI)

    John C. Weigle

    2006-10-01T23:59:59.000Z

    Wilethane 44 is a polyurethane adhesive developed by the Materials Team within ESA-MEE at Los Alamos National Laboratory as a replacement for Hexcel Corporation Urethane 7200. Urethane 7200 is used in numerous weapon systems, but it was withdrawn from the market in 1989. The weapons complex requires a replacement material for use in the W76-1 LEP and the W88, as well as for assembly of JTAs for other warheads. All polyurethane systems are susceptible to moisture reacting with unreacted isocyanate groups. This side reaction competes with the curing reaction and results in CO{sub 2} formation. Therefore, a polyurethane adhesive can exhibit foaming if appropriate environmental controls are not in place while it cures. A designed experiment has been conducted at TA-16-304 to determine the effects of ambient conditions on the properties of cured Wilethane 44. Temperature was varied from 15 C to 30 C and relative humidity from 15% to 40%. The density, hardness at 24 hours, and butt tensile strength on aluminum substrates were measured and fitted to quadratic equations over the experimental space. Additionally, the loss and storage moduli during cure were monitored as a function of cure temperature. These experiments provide a stronger basis for establishing appropriate environmental conditions and cure times when using Wilethane 44. The current guidelines are a working time of 90 minutes, a cure time of 18 hours, and a relative humidity of less than 25%, regardless of ambient temperature. Viscosity measurements revealed that the working time is a strong function of temperature and can be as long as 130 minutes at 15 C or as short as 90 minutes at 30 C. The experiments also showed that the gel time is much longer than originally thought, as long as 13 hours at 15 C. Consequently, it may be necessary to extend the required cure time at temperatures below 20 C. Allowable humidity varies as a function of temperature from 34% at 15 C to 15% at 30 C.

  15. Wavelength-encoded optical psychrometer for relative humidity measurement

    SciTech Connect (OSTI)

    Montanini, Roberto [Department of Industrial Chemistry and Materials Engineering, University of Messina, I-98166 Messina (Italy)

    2007-02-15T23:59:59.000Z

    In this article an optical psychrometer, in which temperature measurements are performed by means of two fiber Bragg grating sensors used as dry-bulb and wet-bulb thermometers, is introduced. The adopted design exploits both the high accuracy of psychrometric-based relative humidity measurements with acknowledged advantages of wavelength-encoded fiber optic sensing. Important metrological issues that have been addressed in the experimental work include calibration of the fiber Bragg grating temperature sensors, evaluation of response time, sensitivity, hysteresis, linearity, and accuracy. The calibration results give confidence that, with the current experimental setup, measurement of temperature can be done with an uncertainty of {+-}0.2 deg. C and a resolution of 0.1 deg. C. A detailed uncertainty analysis is also presented in the article to investigate the effects produced by different sources of error on the combined standard uncertainty u{sub c}(U) of the relative humidity measurement, which has been estimated to be roughly within {+-}2% in the range close to saturation.

  16. Integrated Temperature and Humidity Control: A Unique Approach 

    E-Print Network [OSTI]

    Shah, D. J.

    2000-01-01T23:59:59.000Z

    the dry-bulb temperature within the conditioned space. This can result in the space dew-point temperature increasing to uncomfortable levels, especially during cool and humid times of the day and/or when there is high latent gain. Consequently...

  17. Building America Indoor Temperature and Humidity Measurement Protocol

    SciTech Connect (OSTI)

    Engebrecht-Metzger, C.; Norton, P.

    2014-02-01T23:59:59.000Z

    When modeling homes using simulation tools, the heating and cooling set points can have a significant impact on home energy use. Every 4 years the Energy Information Administration (EIA) Residential Energy Consumption Survey (RECS) asks homeowners about their heating and cooling set points. Unfortunately, no temperature data is measured, and most of the time, the homeowner may be guessing at this number. Even one degree Fahrenheit difference in heating set point can make a 5% difference in heating energy use! So, the survey-based RECS data cannot be used as the definitive reference for the set point for the 'average occupant' in simulations. The purpose of this document is to develop a protocol for collecting consistent data for heating/cooling set points and relative humidity so that an average set point can be determined for asset energy models in residential buildings. This document covers the decision making process for researchers to determine how many sensors should be placed in each home, where to put those sensors, and what kind of asset data should be taken while they are in the home. The authors attempted to design the protocols to maximize the value of this study and minimize the resources required to achieve that value.

  18. Problem 7-3: The air enters with a dry-bulb temperature of 50 o F and, at 50% relative humidity, with a wet-

    E-Print Network [OSTI]

    cooling water leaves the condenser at To = 8 o F below the temperature of the condensing steam F. Therefore the air flow is less than we might have hoped for with a large cooling tower water, leaving the cooling tower and entering the condenser at TCWin = 70 o F, this amount of heat

  19. High Temperature, Low Relative Humidity, Polymer-type Membranes Based on Disulfonated Poly(arylene ether) Block and Random Copolymers Optionally Incorporating Protonic Conducting Layered Water insoluble Zirconium Fillers

    SciTech Connect (OSTI)

    McGrath, James E.; Baird, Donald G.

    2010-06-03T23:59:59.000Z

    Our research group has been engaged in the past few years in the synthesis of biphenol based partially disulfonated poly(arylene ether sulfone) random copolymers as potential PEMs. This series of polymers are named as BPSH-xx, where BP stands for biphenol, S stands for sulfonated, H stands for acidified and xx represents the degree of disulfonation. All of these sulfonated copolymers phase separate to form nano scale hydrophilic and hydrophobic morphological domains. The hydrophilic phase containing the sulfonic acid moieties causes the copolymer to absorb water. Water confined in hydrophilic pores in concert with the sulfonic acid groups serve the critical function of proton (ion) conduction and water transport in these systems. Both Nafion and BPSH show high proton conductivity at fully hydrated conditions. However proton transport is especially limited at low hydration level for the BPSH random copolymer. It has been observed that the diffusion coefficients of both water and protons change with the water content of the pore. This change in proton and water transport mechanisms with hydration level has been attributed to the solvation of the acid groups and the amount of bound and bulk-like water within a pore. At low hydration levels most of the water is tightly associated with sulfonic groups and has a low diffusion coefficient. This tends to encourage isolated domain morphology. Thus, although there may be significant concentrations of protons, the transport is limited by the discontinuous morphological structure. Hence the challenge lies in how to modify the chemistry of the polymers to obtain significant protonic conductivity at low hydration levels. This may be possible if one can alter the chemical structure to synthesize nanophase separated ion containing block copolymers. Unlike the BPSH copolymers, where the sulfonic acid groups are randomly distributed along the chain, the multiblock copolymers will feature an ordered sequence of hydrophilic and hydrophobic segments. If, like in Nafion, connectivity is established between the hydrophilic domains in these multiblock copolymers, they will not need as much water, and hence will show much better protonic conductivity than the random copolymers (with similar degree of sulfonation, or IEC) at partially hydrated conditions. The goal of this research is to develop a material suitable for use as a polymer electrolyte membrane which by the year 2010 will meet all the performance requirements associated with fuel cell operation at high temperatures and low relative humidity, and will out-perform the present standard Nafion{reg_sign}. In particular, it is our objective to extend our previous research based on the use of thermally, oxidatively, and hydrolytically, ductile, high Tg ion containing polymers based on poly(arylene ethers) to the production of polymer electrolyte membranes which will meet all the performance requirements in addition to having an areal resistance of < 0.05 ohm-cm{sup 2} at a temperature of up to 120 C, relative humidity of 25 to 50%, and up to 2.5 atm total pressure. In many instances, our materials already out performs Nafion{reg_sign}, and it is expected that with some modification by either combining with conductive inorganic fillers and/or synthesizing as a block copolymer it will meet the performance criteria at high temperatures and low relative humidity. A key component in improving the performance of the membranes (and in particular proton conductivity) and meeting the cost requirements of $40/m{sup 2} is our development of a film casting process, which shows promise for generation of void free thin films of uniform thickness with controlled polymer alignment and configuration.

  20. Relative Humidity in Limited Streamer Tubes for Stanford Linear Accelerator Center's BaBar Detector

    SciTech Connect (OSTI)

    Lang, M.I.; /MIT; Convery, M.; /SLAC; Menges, W.; /Queen Mary, U. of London

    2005-12-15T23:59:59.000Z

    The BABAR Detector at the Stanford Linear Accelerator Center studies the decay of B mesons created in e{sup +}e{sup -} collisions. The outermost layer of the detector, used to detect muons and neutral hadrons created during this process, is being upgraded from Resistive Plate Chambers (RPCs) to Limited Streamer Tubes (LSTs). The standard-size LST tube consists of eight cells, where a silver-plated wire runs down the center of each. A large potential difference is placed between the wires and ground. Gas flows through a series of modules connected with tubing, typically four. LSTs must be carefully tested before installation, as it will be extremely difficult to repair any damage once installed in the detector. In the testing process, the count rate in most modules showed was stable and consistent with cosmic ray rate over an approximately 500 V operating range between 5400 to 5900 V. The count in some modules, however, was shown to unexpectedly spike near the operation point. In general, the modules through which the gas first flows did not show this problem, but those further along the gas chain were much more likely to do so. The suggestion was that this spike was due to higher humidity in the modules furthest from the fresh, dry inflowing gas, and that the water molecules in more humid modules were adversely affecting the modules' performance. This project studied the effect of humidity in the modules, using a small capacitive humidity sensor (Honeywell). The sensor provided a humidity-dependent output voltage, as well as a temperature measurement from a thermistor. A full-size hygrometer (Panametrics) was used for testing and calibrating the Honeywell sensors. First the relative humidity of the air was measured. For the full calibration, a special gas-mixing setup was used, where relative humidity of the LST gas mixture could be varied from almost dry to almost fully saturated. With the sensor calibrated, a set of sensors was used to measure humidity vs. time in the LSTs. The sensors were placed in two sets of LST modules, one gas line flowing through each set. These modules were tested for count rate v. voltage while simultaneously measuring relative humidity in each module. One set produced expected readings, while the other showed the spike in count rate. The relative humidity in the two sets of modules looked very similar, but it rose significantly for modules further along the gas chain.

  1. RELATIVE HUMIDITY TESTS IN SUPPORT OF THE 3013 STORAGE AND SURVEILLANCE PROGRAM

    SciTech Connect (OSTI)

    Mickalonis, J.; Duffey, J.

    2011-08-01T23:59:59.000Z

    Techniques to control the initial relative humidity over oxide/salt mixtures have been developed using cerium oxide as a surrogate for plutonium oxide. Such control is required to validate certain assumptions in the Department of Energy Standard DOE-STD-3013, and to provide essential information to support field surveillance at the storage sites for excess plutonium oxides. Concern over the validity of the assumption that corrosion induced degradation in 3013 containers could be controlled by assuring that the moisture content of any stored oxide/salt mixture was below 0.5 w t% arose when stress corrosion cracks were found in test samples exposed at room temperature to plutonium oxide/salt mixtures having a moisture content only marginally above 0.5 wt %. Additionally, analysis of the stress corrosion cracking observations suggests that the initial relative humidity over the oxide/salt mixture may play a major role in the cracking process. The investigations summarized in this report provide the procedures necessary to control the initial relative humidity to selected values within the range of 16 to 50% by controlling the loading relative humidity (18 to 60%) and the oxide/salt mixture water content (0.05 to 0.45 wt %). The studies also demonstrated that the initial relative humidity may be estimated by calculations using software EQ3/6. Cerium oxide/salt mixtures were used in this study because qualification tests with non-radioactive materials will reduce costs while increasing the breadth of the test programs required to support field surveillances of stored 3013 containers.

  2. High Temperature/Low Humidity Polymer Electrolytes Derived from Ionic Liquids

    Broader source: Energy.gov [DOE]

    Presentation on High Temperature/Low Humidity Polymer Electrolytes Derived from Ionic Liquids to the High Temperature Membrane Working Group Meeting held in Arlington, Virginia, May 26,2005.

  3. Understanding the Temperature and Humidity Environment Inside a PV Module (Presentation), NREL (National Renewable Energy Laboratory)

    Broader source: Energy.gov [DOE]

    This PowerPoint presentation was originally given by Michael Kempe of NREL in February 2013 detailing a project funded by the SunShot Initiative. Understanding the Temperature and Humidity Environment Inside a PV Module aims to show that by choosing humidity conditions that more closely match the use environment, one can minimize the uncertainty associated with moisture induced degradation modes.

  4. An Experimental Evaluation of HVAC-Grade Carbon-Dioxide Sensors: Part 3, Humidity, Temperature, and Pressure Sensitivity Test Results

    SciTech Connect (OSTI)

    Shrestha, Som S [ORNL; Maxwell, Dr. Gregory [Iowa State University

    2010-01-01T23:59:59.000Z

    This is the third paper in a four-part series reporting on the test and evaluation of typical carbon-dioxide sensors used in building HVAC applications. Fifteen models of NDIR HVAC-grade CO2 sensors were tested and evaluated to determine the humidity, temperature, and pressure sensitivity of the sensors. This paper reports the performance of the sensors at various relative humidity, temperature, and pressure levels common to building HVAC applications and provides a comparison with manufacturer specifications. Among the 15 models tested, eight models have a single-lamp, single-wavelength configuration, four models have a dual-lamp, single-wavelength configuration, and three models have a single-lamp, dual-wavelength configuration. The sensors were tested in a chamber specifically fabricated for this research. A description of the apparatus and the method of test are described in Part 1 (Shrestha and Maxwell 2009). The test result showed a wide variation in humidity, temperature, and pressure sensitivity of CO2 sensors among manufacturers. In some cases, significant variations in sensor performance exist between sensors of the same model. Even the natural variation in relative humidity could significantly vary readings of some CO2 sensor readings. The effects of temperature and pressure variation on NDIR CO2 sensors are unavoidable without an algorithm to compensate for the changes. For the range of temperature and pressure variation in an air-conditioned space, the effect of pressure variation is more significant compared to the effect of temperature variation.

  5. Instrument uncertainty effect on calculation of absolute humidity using dewpoint, wet-bulb, and relative humidity sensors

    SciTech Connect (OSTI)

    Slayzak, S.J.; Ryan, J.P.

    1998-04-01T23:59:59.000Z

    As part of the US Department of Energy`s Advanced Desiccant Technology Program, the National Renewable Energy Laboratory (NREL) is characterizing the state-of-the-art in desiccant dehumidifiers, the key component of desiccant cooling systems. The experimental data will provide industry and end users with independent performance evaluation and help researchers assess the energy savings potential of the technology. Accurate determination of humidity ratio is critical to this work and an understanding of the capabilities of the available instrumentation is central to its proper application. This paper compares the minimum theoretical random error in humidity ratio calculation for three common measurement methods to give a sense of the relative maximum accuracy possible for each method assuming systematic errors can be made negligible. A series of experiments conducted also illustrate the capabilities of relative humidity sensors as compared to dewpoint sensors in measuring the grain depression of desiccant dehumidifiers. These tests support the results of the uncertainty analysis. At generally available instrument accuracies, uncertainty in calculated humidity ratio for dewpoint sensors is determined to be constant at approximately 2%. Wet-bulb sensors range between 2% and 6% above 10 g/kg (4%--15% below), and relative humidity sensors vary between 4% above 90% rh and 15% at 20% rh. Below 20% rh, uncertainty for rh sensors increases dramatically. Highest currently attainable accuracies bring dewpoint instruments down to 1% uncertainty, wet bulb to a range of 1%--3% above 10 g/kg (1.5%--8% below), and rh sensors between 1% and 5%.

  6. Effects of Sodium Chloride Particles, Ozone, UV, and Relative Humidity on Atmospheric Corrosion of Silver

    E-Print Network [OSTI]

    Effects of Sodium Chloride Particles, Ozone, UV, and Relative Humidity on Atmospheric Corrosion The corrosion of Ag contaminated with NaCl particles in gaseous environments containing humidity and ozone analyzed using a coulometric reduction technique. The atmospheric corrosion of Ag was greatly accelerated

  7. Temperature and humidity control during cooling and dehumidifying by compressor and evaporator fan speed variation

    SciTech Connect (OSTI)

    Krakow, K.I.; Lin, S.; Zeng, Z.S. [Concordia Univ., Montreal, Quebec (Canada). Dept. of Mechanical Engineering

    1995-08-01T23:59:59.000Z

    The accurate control of temperature and relative humidity during cooling and dehumidifying air-conditioning processes may be achieved by compressor and evaporator fan speed variation. Proportional-integral-differential (PID) control methods are shown to be suitable for attaining compressor and evaporator fan speeds such that the sensible and latent components of the refrigeration system capacity equal the sensible and latent components of the system load. The feasibility of the control method has been verified experimentally. A numerical model of an environmental control system, including refrigeration, space, and PID control subsystems, has been developed. The model is suitable for determining system response to variations of PID coefficient values and to variations of system loads.

  8. An Experimental Evaluation of Duct-Mounted Relative Humidity Sensors: Part 2 – Accuracy Results 

    E-Print Network [OSTI]

    Joshi, S.N.; Pate, M.B.; Nelson, R.M; House, J.H.; Klaasen, C.J.

    2005-01-01T23:59:59.000Z

    Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. An Experimental Evaluation of Duct-Mounted Relative Humidity Sensors: Part 2-Accuracy Results Joshi, Shailesh N;House, John M;Pate, Michael B...

  9. An Experimental Evaluation of Duct-Mounted Relative Humidity Sensors: Part 1 – Test and Evaluation Procedures 

    E-Print Network [OSTI]

    Joshi, S.N.; Pate, M.B.; Nelson, R.M.; House, R.H.; Klaasen, C.J.

    2005-01-01T23:59:59.000Z

    Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. An Experimental Evaluation of Duct-Mounted Relative Humidity Sensors: Part 1, Test and Evaluation... Joshi, Shailesh N;Pate, Michael B...

  10. Maintaining Space Temperature and Humidity in the Digital Switch Environment

    E-Print Network [OSTI]

    Saman, N. F.; Johnson, H.

    the humidifier if Case A-l is used, Btu/lb Dhjj = enthalpy difference across the humidifier if Case A-2 is used, Btu/lb Dhcnjner = enthalpy difference across the sensible cooling process, case A-2, Btu/lb Case B: The outside air dry bulb temperature is higher.... Isothermal humidification (steam generator or infrared heater). b. Adiabatic humidification (evaporative cooler or ultrasonic humidification). METHODOLOGY 1. Obtain the bin data for the location (see Table 1 below for sample bin data). Table 1. Temperature...

  11. The use of data from the NIMBUS II satellite to determine the mean relative humidity in the layer below 500 mb

    E-Print Network [OSTI]

    Morrissette, John Francis

    1967-01-01T23:59:59.000Z

    for different kinds of cloud cover. 18 2. The relationship between the mean relative humidity below the 500-mb level and the temperatures sensed by the Channel 4 radiometer 21 LIST OF TABLES Table Page 1. The simple correlation between the mean relative... of radiation in the 5. 8 to 6. 8 micron band (the "water vapor" channel) measured by the early TIROS satellites is in effect a measure of the mean relative humidity of the troposphere, provided that the temperature profile is known. Following this work...

  12. Effects of Temperature and Humidity on the Characterization of C-4 Explosive Threats

    SciTech Connect (OSTI)

    C. J. Miller

    2012-06-01T23:59:59.000Z

    The amount of time that an explosive is present on the surface of a material is dependent upon the original amount of explosive on the surface, adhesive forces, temperature and humidity, as well as other environmental factors. This laboratory study focused on evaluating RDX crystal morphology changes resulting from variations in temperature and humidity conditions of the sample. The temperature and humidity conditions were controlled using a Tenney THRJ environmental chamber and a Tenney T11RC-1.5 environmental chamber. These chambers allow the temperature and humidity to be held within ±3°C and ±5% RH. The temperature and humidity conditions used for this test series were: 40°F/40%RH, ~70°F/20%RH (samples left on benchtop), 70°F/70%RH, 70°F/95%RH, 95°F/40%RH, 95°F/70%RH, and 95°F/95%RH. These temperature and humidity set points were chosen to represent a wide range of conditions that may be found in real world scenarios. C-4 (RDX crystals and binder material) was deposited on the surface of one of six substrates by placing a fingerprint from the explosive block onto the matrix surface. The substrates were chosen to provide a range of items that are commonly used. Six substrate types were used during these tests: 50% cotton/50% polyester as found in T-shirts, 100% cotton with a smooth surface such as that found in a cotton dress shirt, 100% cotton on a rough surface such as that found on canvas or denim, suede leather such as might be found on jackets, purses, or shoes, painted metal obtained from a junked car hood, and a computer diskette. The samples were not pre-cleaned prior to testing and contained sizing agents, and in the case of the metal: oil, dirt, scratches, and rust spots. The substrates were photographed at various stages of testing, using a Zeiss Discover V12 stereoscope with Axiocam ICc1 3 megapixel digital camera, to determine any changes in the crystalline morphology. Some of the samples were examined using scanning electron microscopy (SEM) and atomic force microscopy (AFM) in an attempt to determine how the explosive was bound to the substrate.

  13. Analytical determination of PID coefficients for temperature and humidity control during cooling and dehumidifying by compressor and evaporator fan speed variation

    SciTech Connect (OSTI)

    Krakow, K.I.; Lin, S.; Zeng, Z.S. [Concordia Univ., Montreal, Quebec (Canada). Dept. of Mechanical Engineering

    1995-08-01T23:59:59.000Z

    A linearized analysis of temperature and relative humidity control using proportional-integral-differential (PID) controls to vary compressor motor speed and evaporator fan speed enables analytical determination of suitable PID coefficients. The PID coefficients are related to refrigeration system performance parameters and the volume of the conditioned space. Analytical determination of coefficients may eliminate or supplement trial-and-error methods. System response characteristics--damping ratios and periods--are related to PID coefficients, sampling intervals, performance parameters of a refrigeration system, and the volume of a conditioned space. Two control strategies are possible in order to control space temperature and relative humidity simultaneously. One strategy controls temperature by varying compressor speed and controls relative humidity by varying evaporator fan speed. The other strategy controls temperature by varying evaporator fan speed and controls relative humidity by varying compressor fan speed The first strategy was successfully implemented experimentally as well as by simulation. The second strategy was not successfully implemented due to an adverse interaction between the two control systems.

  14. IEC Quality Assurance Task Group 5: UV, Temperature, and Humidity (Presentation)

    SciTech Connect (OSTI)

    Miller, D.; Bath, J.; Kohl, M.; Shioda, T.

    2014-03-01T23:59:59.000Z

    Taskgroup 5 (TG5) is concerned with a comparative aging standard incorporating factors including ultraviolet radiation, temperature, and humidity. Separate experiments are being conducted in support of a test standard via the regional sub-groups in Asia, Europe, and the United States. The authors will describe the objectives and timeline for TG5 as well as providing an update on the experiments in progress.

  15. Humidity-resistant ambient-temperature solid-electrolyte amperometric sensing apparatus

    DOE Patents [OSTI]

    Zaromb, S.

    1994-06-21T23:59:59.000Z

    Apparatus and methods for detecting selected chemical compounds in air or other gas streams at room or ambient temperature includes a liquid-free humidity-resistant amperometric sensor comprising a sensing electrode and a counter and reference electrode separated by a solid electrolyte. The sensing electrode preferably contains a noble metal, such as Pt black. The electrolyte is water-free, non-hygroscopic, and substantially water-insoluble, and has a room temperature ionic conductivity [>=]10[sup [minus]4] (ohm-cm)[sup [minus]1], and preferably [>=]0.01 (ohm-cm)[sup [minus]1]. The conductivity may be due predominantly to Ag[sup +] ions, as in Ag[sub 2]WO[sub 4], or to F[sup [minus

  16. An Experimental Evaluation of Duct-Mounted Relative Humidity Sensors: Part 3 – Repeatability, Hysteresis and Linearity Results 

    E-Print Network [OSTI]

    Joshi, S.N.; Pate, M.B.; Nelson, R.M.; House, J.H.; Klaassen, C.J.

    2005-01-01T23:59:59.000Z

    Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. An Experimental Evaluation of Duct-Mounted Relative Humidity Sensors: Part 3-Repeatability, Hyste... Joshi, Shailesh N;House, John M...

  17. Understanding the Temperature and Humidity Environment Inside a PV Module (Presentation)

    SciTech Connect (OSTI)

    Kempe, M.

    2013-06-01T23:59:59.000Z

    This presentation addresses moisture-driven degradation processes in PV modules and the conditions to use for accelerated stress testing. Here we show that by choosing humidity conditions that more closely match the use environment, one can minimize the uncertainty associated with moisture induced degradation modes.

  18. The Impacts of Indirect Soil Moisture Assimilation and Direct Surface Temperature and Humidity Assimilation on a Mesoscale Model Simulation of an Indian

    E-Print Network [OSTI]

    Niyogi, Dev

    Assimilation on a Mesoscale Model Simulation of an Indian Monsoon Depression VINODKUMAR AND A. CHANDRASEKAR-generation Pennsylvania State University­NCAR Mesoscale Model (MM5) simulation utilized the humidity and temperature

  19. Development of Temperature and Humidity-Based Indicators for Diagnosing Problems in Low Tonnage, Split System Air Conditioners

    E-Print Network [OSTI]

    Watt, J. B.; O'Neal, D. L.; Haberl, J. S.

    1998-01-01T23:59:59.000Z

    of meeting a given cooling load; and equipment safety, or the ability to maintain equipment longevity by avoiding equipment-life-reducing conditions such as compressor slugging (no superheat) or lack of compressor cooling (high superheat) or seal...DEVELOPMENT OF TEMPERATURE AND HUMIDITY-BASED INDICATORS FOR DIAGNOSING PROBLEMS IN LOW TONNAGE, SPLIT SYSTEM AIR CONDITIONERS Jim Watt Jeff Haberl, P.E., PhD. Dennis O'Neai, P.E., PhD. CES/Way International, Inc. Energy Systems Laboratory Energy...

  20. IEEE GEOSCIENCE AND REMOTE SENSING LETTERS 1 Assessment of Temperature and Humidity Changes

    E-Print Network [OSTI]

    Christopher, Sundar A.

    IEEEProof IEEEProof IEEE GEOSCIENCE AND REMOTE SENSING LETTERS 1 Assessment of Temperature multiple satellite7 remote sensing data sets and meteorological information, we assess8 the distribution observed at some15 locations. Between the surface and 2-km level, temperature data16 show a cooling of 10

  1. The herbicidal effectiveness of 2,4-dichlorophenoxyacetic acid and 2,3,6,-trichlorobenzoic acid on beans as influenced by relative humidity and droplet size

    E-Print Network [OSTI]

    Morgan, Page Wesley

    1958-01-01T23:59:59.000Z

    THE HERBICIDAL EFFECTIVENESS OF 2, 4-DICHLOROPHENOXYACETIC ACID AND 2, 3, 6-TRICHLOROBENZOIC ACID ON BEANS AS INFLUENCED BY RELATIVE HUMIDITY AND DROPLET SIZE By PAGE WESLEY MORGAN A Thesis Submitted to the Graduate School... TRICHLOROBENZO IC AC ID ON BEANS AS INFLUENCED BY RELATIVE HUMIDITY AND DROPLET SIZE A Thesis By PAGE WESLEY MORGAN Approved as to style and content by: / (Chairman of Commi ee) (Head of Dep e January, 1958 ACKNOWLEDGEMENT S With deepest appreciation...

  2. Polyimide Capacitive Humidity Sensors 

    E-Print Network [OSTI]

    Lofgren, H.; Mills, F.

    1988-01-01T23:59:59.000Z

    The need for a full-range, low cast humidity sensor has led Honeywell to develop a capacitive relative humidity (RH) sensor with resistance to environmental contaminants. The sensor is used in a bridge circuit to give either a voltage or a current...

  3. Polyimide Capacitive Humidity Sensors

    E-Print Network [OSTI]

    Lofgren, H.; Mills, F.

    1988-01-01T23:59:59.000Z

    The need for a full-range, low cast humidity sensor has led Honeywell to develop a capacitive relative humidity (RH) sensor with resistance to environmental contaminants. The sensor is used in a bridge circuit to give either a voltage or a current...

  4. IEC Quality Assurance Task Group 5: UV, Temperature, and Humidity (Presentation)

    SciTech Connect (OSTI)

    Miller, D.; Bath, J.; K& ouml; hl, M.; Shioda, T.

    2014-06-01T23:59:59.000Z

    Taskgroup 5 (TG5) is concerned with a comparative aging standard incorporating factors including ultraviolet radiation and temperature. Separate experiments are being conducted in support of a test standard via the regional sub-groups in Asia, Europe, and the United States. The authors will describe the objectives and timeline for TG5 as well as providing an update on the experiments in progress.

  5. A FULLY COUPLED THERMO-HYDRO MECHANICAL ANALYSIS OF THE IMPACT OF TEMPERATURE AND HUMIDITY VARIATION ON THE STATE OF HISTORICAL STONE

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    A FULLY COUPLED THERMO-HYDRO MECHANICAL ANALYSIS OF THE IMPACT OF TEMPERATURE AND HUMIDITY Keywords: Thermo-hydro-mechanical coupling, modelling, inverse problem, tuffeau, monument, in situ measures initiation and growth due to the variation of climate conditions; thermo-hydro-mechanical incompatibility

  6. Humidity Control in Residences

    E-Print Network [OSTI]

    Trowbridge, J.; Peterson, J.

    1994-01-01T23:59:59.000Z

    . By introducing a separate vapor compression unit to pre-condition outside air, indoor relative humidity can be controlled. This new air conditioning system combines a ventilation unit with a conventional recirculation air conditioning unit. Although successful...

  7. 20th Century Reanalysis Project Ensemble Gateway: 56 Estimates of World Temperature, Pressure, Humidity, and Wind, 1871-2010

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    This site provides data from the 20th Century Reanalysis Project, offering temperature, pressure, humidity, and wind predictions in 200 km sections all around the earth from 1871 to 2010, every 6 hours, based on historical data. The ensemble mean and standard deviation for each value were calculated over a set of 56 simulations. Data for each of the 56 ensemble members are included here. The dataset consists of files in netCDF 4 format that are available for download from the National Energy Research. The goal of the 20th Century Reanalysis Project is to use a Kalman filter-based technique to produce a global trophospheric circulation dataset at four-times-daily resolution back to 1871. The only dataset available for the early 20th century consists of error-ridden hand-drawn analyses of the mean sea level pressure field over the Northern Hemisphere. Modern data assimilation systems have the potential to improve upon these maps, but prior to 1948, few digitized upper-air sounding observations are available for such a reanalysis. The global tropospheric circulation dataset will provide an important validation check on the climate models used to make 21st century climate projections....[copied from http://portal.nersc.gov/project/20C_Reanalysis/

  8. The use of satellite cloud pictures to determine average relative humidity below 500 mb

    E-Print Network [OSTI]

    West, Philip Walter

    1966-01-01T23:59:59.000Z

    -Gratch equation (Wurtele and Finke, 1961) 1 g10 s 7'90298( ~ 1) 373. 16 + 5. 02808 log10 373. 16 11. 344(1 ? ~) 1. 3816 x 10 [10 -I] 49149 (373 ~ 16 + 8. 1328 x 10 [10 -I] + log10 1013. 26 (4) where e is def ined as above and T is the temperature...

  9. The use of data from the NIMBUS II satellite to determine the mean relative humidity in the layer below 500 mb 

    E-Print Network [OSTI]

    Morrissette, John Francis

    1967-01-01T23:59:59.000Z

    of the requirements for the degree of MASTER OF SCIENCE May 1967 Major Subject: METEOROLOGY THE USE OF DATA FROM THE NIMBUS II SATELLITE TO DETERMINE THE MEAN RELATIVE HUMIDITY IN THE LAYER BELON 5OO MB A Thesis By JOHN FRANCIS MORRISSFTTE Approved... as to style and content by: (Ch rrman of Committee) (Head of Departme & (Member) (Member) (Member) May 1967 ABSTRACT The Use of Data From the NIMBUS II Satellite to Determine the Mean Relative Humidity in the Layer Below 500 mb. (May 1967) John Francis...

  10. Supplementary Figure 1| Neutron diffraction data at 86 % relative humidity. a) Schematic representation of neutron diffraction geometry for -2 scans. Diffraction data are obtained

    E-Print Network [OSTI]

    White, Stephen

    distributions of lipid and protein under varying levels of hydration. Predicted neutron scattering profiles as number density profiles weighted by the neutron scattering lengths of individual atoms, then symmetrizedSupplementary Figure 1| Neutron diffraction data at 86 % relative humidity. a) Schematic

  11. Light Absorption by Secondary Organic Aerosol from ?-Pinene: Effects of Oxidants, Seed Aerosol Acidity, and Relative Humidity

    SciTech Connect (OSTI)

    Song, Chen; Gyawali, Madhu S.; Zaveri, Rahul A.; Shilling, John E.; Arnott, W. Patrick

    2013-10-25T23:59:59.000Z

    It is well known that light absorption from dust and black carbon aerosols has a warming effect on climate while light scattering from sulfate, nitrate, and sea salt aerosols has a cooling effect. However, there are large uncertainties associated with light absorption and scattering by different types of organic aerosols, especially in the near-UV and UV spectral regions. In this paper, we present the results from a systematic laboratory study focused on measuring light absorption by secondary organic aerosols (SOA) generated from ozonolysis or NO3 oxidation of ?-pinene in the presence of neutral and acidic sulfate seed aerosols. Light absorption was monitored using photoacoustic spectrometers at four different wavelengths: 355, 405, 532 and 870 nm. Light absorption at 355 and 405 nm was observed by SOA generated from oxidation of ?-pinene in the presence of acidic sulfate seed aerosols, under dry conditions. No absorption was observed when the relative humidity was elevated to greater than 27%, or in the presence of neutral sulfate seed aerosols. The light-absorbing compounds are speculated to be aldol condensation oligomers with organosulfate and organic nitrate groups. The results of this study also indicate that organic nitrates from ?-pinene SOA formed in the presence of neutral sulfate seed aerosols do not appear to absorb near-UV and UV radiation.

  12. Humidity requirements in WSCF Laboratories

    SciTech Connect (OSTI)

    Evans, R.A.

    1994-10-01T23:59:59.000Z

    The purpose of this paper is to develop and document a position on Relative Humidity (RH) requirements in the WSCF Laboratories. A current survey of equipment vendors for Organic, Inorganic and Radiochemical laboratories indicate that 25% - 80% relative humidity may meet the environmental requirements for safe operation and protection of all the laboratory equipment.

  13. Accelerated Laboratory Tests Using Simultaneous UV, Temperature...

    Broader source: Energy.gov (indexed) [DOE]

    ,nm nm * High UV Radiant Exposure (8400 W UV) * 95% exposure uniformity * Visible and infrared radiation mostly removed * Temperature and relative humidity around specimens...

  14. The effect of temperature and relative humidity levels upon charcoal tube sampling for vinyl choloride

    E-Print Network [OSTI]

    McCaskill, Gerald Daniel

    1983-01-01T23:59:59.000Z

    their cooperation, this research would not have been possible. I also wish to express my appreciation to the National Institute for Occupational Safety and Health which prov ided an educational grant. DEDICATION To Ann, Your love, words of encouragement... of their employees from angiosarcoma to prolonged vinyl chloride monomer (UCM) exposure. (I) The government immediately stepped in, and by Febr uary 1974, the National Institute for Occupational Safety and Health (NIOSH) had issued a set of recommendations...

  15. The frequency of tropopause-level thick and thin cirrus clouds as observed by CALIPSO and the relationship to relative humidity and outgoing longwave radiation

    E-Print Network [OSTI]

    Cardona, Allison Leanne

    2008-10-10T23:59:59.000Z

    THE FREQUENCY OF TROPOPAUSE-LEVEL THICK AND THIN CIRRUS CLOUDS AS OBSERVED BY CALIPSO AND THE RELATIONSHIP TO RELATIVE HUMIDITY AND OUTGOING LONGWAVE RADIATION A Thesis by ALLISON L. CARDONA Submitted to the Office of Graduate... Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE August 2008 Major Subject: Atmospheric Sciences THE FREQUENCY OF TROPOPAUSE-LEVEL THICK AND THIN CIRRUS CLOUDS AS OBSERVED...

  16. Measure Guideline: Supplemental Dehumidification in Warm-Humid Climates

    SciTech Connect (OSTI)

    Rudd, A.

    2014-10-01T23:59:59.000Z

    This document covers a description of the need and applied solutions for supplemental dehumidification in warm-humid climates, especially for energy efficient homes where the sensible cooling load has been dramatically reduced. In older homes in warm-humid climates, cooling loads are typically high and cooling equipment runs a lot to cool the air. The cooling process also removes indoor moisture, reducing indoor relative humidity. However, at current residential code levels, and especially for above-code programs, sensible cooling loads have been so dramatically reduced that the cooling system does not run a lot to cool the air, resulting in much less moisture being removed. In these new homes, cooling equipment is off for much longer periods of time especially during spring/fall seasons, summer shoulder months, rainy periods, some summer nights, and some winter days. In warm-humid climates, those long off periods allow indoor humidity to become elevated due to internally generated moisture and ventilation air change. Elevated indoor relative humidity impacts comfort, indoor air quality, and building material durability. Industry is responding with supplemental dehumidification options, but that effort is really in its infancy regarding year-round humidity control in low-energy homes. Available supplemental humidity control options are discussed. Some options are less expensive but may not control indoor humidity as well as more expensive and comprehensive options. The best performing option is one that avoids overcooling and avoids adding unnecessary heat to the space by using waste heat from the cooling system to reheat the cooled and dehumidified air to room-neutral temperature.

  17. The effects of temperature and humidity on the eggs of Aedes aegypti (L.) and Aedes albopictus (Skuse) in Texas

    E-Print Network [OSTI]

    Dickerson, Catherine Zindler

    2009-05-15T23:59:59.000Z

    at seven temperatures. The temperature optima (28°-33°C) were similar for all populations; however, the rate of development for Ae. aegypti was significantly faster at the temperature optima. It is likely that this faster development rate in the Ae. aegypti...

  18. High-temperature thermocouples and related methods

    DOE Patents [OSTI]

    Rempe, Joy L. (Idaho Falls, ID); Knudson, Darrell L. (Firth, ID); Condie, Keith G. (Idaho Falls, ID); Wilkins, S. Curt (Idaho Falls, ID)

    2011-01-18T23:59:59.000Z

    A high-temperature thermocouple and methods for fabricating a thermocouple capable of long-term operation in high-temperature, hostile environments without significant signal degradation or shortened thermocouple lifetime due to heat induced brittleness.

  19. OSMOTIC COEFFICIENTS, SOLUBILITIES, AND DELIQUESCENCE RELATIONS IN MIXED AQUEOUS SALT SOLUTIONS AT ELEVATED TEMPERATURE

    SciTech Connect (OSTI)

    M.S. Gruszkiewicz; D.A. Palmer

    2006-02-22T23:59:59.000Z

    While thermodynamic properties of pure aqueous electrolytes are relatively well known at ambient temperature, there are far fewer data for binary systems extending to elevated temperatures and high concentrations. There is no general theoretically sound basis for prediction of the temperature dependence of ionic activities, and consequently temperature extrapolations based on ambient temperature data and empirical equations are uncertain and require empirical verification. Thermodynamic properties of mixed brines in a wide range of concentrations would enhance the understanding and precise modeling of the effects of deliquescence of initially dry solids in humid air in geological environments and in modeling the composition of waters during heating, cooling, evaporation or condensation processes. These conditions are of interest in the analysis of waters on metal surfaces at the proposed radioactive waste repository at Yucca Mountain, Nevada. The results obtained in this project will be useful for modeling the long-term evolution of the chemical environment, and this in turn is useful for the analysis of the corrosion of waste packages. In particular, there are few reliable experimental data available on the relationship between relative humidity and composition that reveals the eutonic points of the mixtures and the mixture deliquescence RH. The deliquescence RH for multicomponent mixtures is lower than that of pure component or binary solutions, but is not easy to predict quantitatively since the solutions are highly nonideal. In this work we used the ORNL low-temperature and high-temperature isopiestic facilities, capable of precise measurements of vapor pressure between ambient temperature and 250 C for determination of not only osmotic coefficients, but also solubilities and deliquescence points of aqueous mixed solutions in a range of temperatures. In addition to standard solutions of CaCl{sub 2}, LiCl, and NaCl used as references, precise direct-pressure measurements were also made at elevated temperatures. The project included multicomponent mixtures useful for verification of models, and a set of binary solutions with common ions (such as KNO{sub 3} + NaNO{sub 3}, KNO{sub 3} + Ca(NO{sub 3}){sub 2}, NaNO{sub 3} + Na{sub 2}SO{sub 4}, and KNO{sub 3} + K{sub 2}SO{sub 4}) needed for determination of the mixing parameters in the Pitzer ion-interaction model for mixtures. The results are compared with existing experimental results and model predictions.

  20. Evaluation of Energy Efficiency Measures in Hot and Humid Climates

    E-Print Network [OSTI]

    Zhao, Y.; Erwine, B.; Leonard, P.; Pease, B.; Dole, A.; Lee, A.

    Hot and humid climates present some of the most complex challenges for sustainable building designs. High temperatures coupled with high humidity create extreme comfort problems and exacerbate the potential for condensation, mold and mildew...

  1. Case Study: Sick Building Syndrome in a Humid Climate

    E-Print Network [OSTI]

    Shaughnessy, R. J.; Levetin, E.

    1990-01-01T23:59:59.000Z

    and evaluation; formaldehyde sampling; particulate sampling; bioaerosol sampling (consisting of nonviable and viable fungi spore sampling); carbon monoxide, carbon dioxide, temperature and relative humidity levels to be monitored over 12-hour periods on two... to the outside" (25). To date, no single satisfactory method is available to measure the amount of cigarette smoke present in a work space. Carbon monoxide and formaldehyde levels were monitored throughout the second and fourth floors to attempt...

  2. Considerations for Energy Efficient Showers in Hot-Humid Climates

    E-Print Network [OSTI]

    Claridge, D. E.; Turner, W. D.

    1989-01-01T23:59:59.000Z

    CONSIDERATIONS FOR ENERGY EFFICIENT SHOWERS IN HOT-HUMID CLIMATES D. E. Claridge and W.D. Turner Energy Systems Laboratory Department of Mechanical Engineering Texas ALM University ABSTRACT Measurements have been conducted on four low... for typical operation in Texas. This has significant implications for everyone who purchases or uses showerheads; this is particularly true in hot climates where supply water temperatures are relatively high. TESTS CONDUCTED Showerheads Tested Two...

  3. Indoor Humidity Analysis of an Integrated Radiant Cooling and Desiccant Ventilation System 

    E-Print Network [OSTI]

    Gong, X.; Claridge, D. E.

    2006-01-01T23:59:59.000Z

    of enthalpy F2 = Ideal isopotential line relative humidity pC = Specific heat capacity (Btu/lb*F) m = Mass flow rate lb/min genm& = Moisture generation lb lb/hr T = Temperature, oF or K rV = Space volume ft 3 sV& = Supplied... propagation characteristics. 8624 49 344.4 28651 w TF + ?= (5) 07969 49 1276360 wT ? (6) 1 1 1 11 1 o o F FF F ? ?=? (7) 1 1 2 22 2 o o F FF F ? ?=? (8) F1 and F2 correspond to isopotential lines of enthalpy and relative humidity. 1F and 2...

  4. Novel Approaches to Immobilized Heteropoly Acid Systems for High Temperature, Low Relative Humidity Polymer-Type Membranes - Final Report

    SciTech Connect (OSTI)

    Herring, Andrew M; Horan, James L; Aieta, Niccolo V; Sachdeva, Sonny; Kuo, Mei-Chen; Ren, Hui; Lingutla, Anitha; Emery, Michael; Haugen, Gregory M; Yandrasits, Michael A; Sharma, Neeraj; Coggio, William D; Hamrock, Steven J; Frey, Matthew H

    2012-05-20T23:59:59.000Z

    Original research was carried out at the CSM and the 3M Company from March 2007 through September 2011. The research was aimed at developing new to the world proton electrolyte materials for use in hydrogen fuel cells, in particular with high proton conductivity under hot and dry conditions (>100mS/cm at 120°C and 50%RH). Broadly stated, the research at 3M and between 3M and CSM that led to new materials took place in two phases: In the first phase, hydrocarbon membranes that could be formed by photopolymerization of monomer mixtures were developed for the purpose of determining the technical feasibility of achieving the program's Go/No-Go decision conductivity target of >100mS/cm at 120°C and 50%RH. In the second phase, attempts were made to extend the achieved conductivity level to fluorinated material systems with the expectation that durability and stability would be improved (over the hydrocarbon material). Highlights included: Multiple lots of an HPA-immobilized photocurable terpolymer derived from di-vinyl-silicotungstic acid (85%), n-butyl acrylate, and hexanediol diacrylate were prepared at 3M and characterized at 3M to exhibit an initial conductivity of 107mS/cm at 120°C and 47%RH (PolyPOM85v) using a Bekktech LLC sample fixture and TestEquity oven. Later independent testing by Bekktech LLC, using a different preheating protocol, on the same material, yielded a conductivity value of approximately 20mS/cm at 120°C and 50%RH. The difference in measured values is likely to have been the result of an instability of properties for the material or a difference in the measurement method. A dispersed catalyst fuel cell was fabricated and tested using a 150¼m thick HPA-based photocurable membrane (above, PolyPOM75v), exhibiting a current density of greater than 300mA/cm2 at 0.5V (H2/Air 800/1800sccm 70°C/75%RH ambient outlet pressure). Multiple lots of a co-polymer based on poly-trifluorovinylether (TFVE) derived HPA were synthesized and fabricated into films, Generation II films. These materials showed proton conductivities as high as 1 S/cm under high RH conditions. However, the materials suffered from compromised properties due to impure monomers and low molecular weights. Multiple lots of an HPA-immobilized fluoropolymer derived from preformed PVDF-HFP (Generation III films) were synthesized and formed into membranes at 3M and characterized at 3M to exhibit conductivity reaching approximately 75mS/cm at 120°C/40%RH using a Bekktech sample fixture and TestEquity oven (optimized membrane, at close of program). Initial fuel cell fabrication and testing for this new class of membrane yielded negative results (no measureable proton conductivity); however, the specific early membrane that was used for the two 5cm2 MEAs was later determined to have <1 mS/cm at 80°C/80%RH using the Bekktech fixture, vs. ca. 200 mS/cm at 80°C/80%RH for samples of the later-optimized type described above. Future work in this area (beyond the presently reported contract) should include additional attempts to fabricate and test fuel cells based on the later-optimized Generation II and III polymer. A manufacturing study was performed which predicted no difficulties in any future scale up of the materials.

  5. Optical humidity sensor

    DOE Patents [OSTI]

    Tarvin, J.A.

    1987-02-10T23:59:59.000Z

    An optical dielectric humidity sensor is disclosed which includes a dielectric mirror having multiple alternating layers of two porous water-adsorbent dielectric materials with differing indices of refraction carried by a translucent substrate. A narrow-band polarized light source is positioned to direct light energy onto the mirror, and detectors are positioned to receive light energy transmitted through and reflected by the mirror. A ratiometer indicates humidity in the atmosphere which surrounds the dielectric mirror as a function of a ratio of light energies incident on the detectors. 2 figs.

  6. HCH-1000 Series Capacitive Humidity Sensor

    E-Print Network [OSTI]

    Rowe, Anthony

    www.honeywell.com/sensing SPECIFICATIONS (TA= 25 ºC [77 ºF], Input Voltage = 1 VRMS, Frequency = 20 k: TEMPERATURE CHARACTERISTICS (At 1 VRMS and 20 kHz) #12;Capacitive Humidity Sensors Honeywell Sensing TEST SYSTEM DIAGRAM #12;Sensing and Control 1985 Douglas Drive North Minneapolis, MN 55422 www.honeywell

  7. Active Humidity Control Through Gas-Fired Desiccant Humidity Pump 

    E-Print Network [OSTI]

    Novosel, D.; Griffiths, W. C.

    1988-01-01T23:59:59.000Z

    applied. A comparison of passive capacity control methods to control humidity shows that only the combined face and bypass and variable air volume system shows improved performance with respect to space humidity control, dew point depression, and response...

  8. Preferred temperature of bluegill, Lepomis macrochirus, relative to changing ambient temperature

    E-Print Network [OSTI]

    Hagar, Arthur Freeman

    1978-01-01T23:59:59.000Z

    -Changes in Ambient Tempezature Figure 5. Relationship of Rate Parameters KC and KW to 21 23 Ambient Tempezatuze Figure 6. Relationship of the Time-Lag Parameter, LAMBDA, to Ambient Temperature 36 Figure 7. Relative Contribution of' the "Warm" (BWE) and "Cold... and cold components of temperature preference are treated separately in the simulation model. Their steaQ-state contributions 39 to TP, which were labeled BWE and BCE, were computed. by 1) arbitrarily setting BWE=O. O C at TA=10. 0 0 and BCE=O. O C...

  9. Evaluation of Humidity Control Options in Hot-Humid Climate Homes (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2011-12-01T23:59:59.000Z

    This technical highlight describes NREL research to analyze the indoor relative humidity in three home types in the hot-humid climate zone, and examine the impacts of various dehumidification equipment and controls. As the Building America program researches construction of homes that achieve greater source energy savings over typical mid-1990s construction, proper modeling of whole-house latent loads and operation of humidity control equipment has become a high priority. Long-term high relative humidity can cause health and durability problems in homes, particularly in a hot-humid climate. In this study, researchers at the National Renewable Energy Laboratory (NREL) used the latest EnergyPlus tool equipped with the moisture capacitance model to analyze the indoor relative humidity in three home types: a Building America high-performance home; a mid-1990s reference home; and a 2006 International Energy Conservation Code (IECC)-compliant home in hot-humid climate zones. They examined the impacts of various dehumidification equipment and controls on the high-performance home where the dehumidification equipment energy use can become a much larger portion of whole-house energy consumption. The research included a number of simulated cases: thermostat reset, A/C with energy recovery ventilator, heat exchanger assisted A/C, A/C with condenser reheat, A/C with desiccant wheel dehumidifier, A/C with DX dehumidifier, A/C with energy recovery ventilator, and DX dehumidifier. Space relative humidity, thermal comfort, and whole-house source energy consumption were compared for indoor relative humidity set points of 50%, 55%, and 60%. The study revealed why similar trends of high humidity were observed in all three homes regardless of energy efficiency, and why humidity problems are not necessarily unique in the high-performance home. Thermal comfort analysis indicated that occupants are unlikely to notice indoor humidity problems. The study confirmed that supplemental dehumidification is needed to maintain space relative humidity (RH) below 60% in a hot-humid climate home. Researchers also concluded that while all the active dehumidification options included in the study successfully controlled space relative humidity excursions, the increase in whole-house energy consumption was much more sensitive to the humidity set point than the chosen technology option. In the high-performance home, supplemental dehumidification equipment results in a significant source energy consumption penalty at 50% RH set point (12.6%-22.4%) compared to the consumption at 60% RH set point (1.5%-2.7%). At 50% and 55% RH set points, A/C with desiccant wheel dehumidifier and A/C with ERV and high-efficiency DX dehumidifier stand out as the two cases resulting in the smallest increase of source energy consumption. At an RH set point of 60%, all explicit dehumidification technologies result in similar insignificant increases in source energy consumption and thus are equally competitive.

  10. Humidity effects on wire insulation breakdown strength.

    SciTech Connect (OSTI)

    Appelhans, Leah

    2013-08-01T23:59:59.000Z

    Methods for the testing of the dielectric breakdown strength of insulation on metal wires under variable humidity conditions were developed. Two methods, an ASTM method and the twisted pair method, were compared to determine if the twisted pair method could be used for determination of breakdown strength under variable humidity conditions. It was concluded that, although there were small differences in outcomes between the two testing methods, the non-standard method (twisted pair) would be appropriate to use for further testing of the effects of humidity on breakdown performance. The dielectric breakdown strength of 34G copper wire insulated with double layer Poly-Thermaleze/Polyamide-imide insulation was measured using the twisted pair method under a variety of relative humidity (RH) conditions and exposure times. Humidity at 50% RH and below was not found to affect the dielectric breakdown strength. At 80% RH the dielectric breakdown strength was significantly diminished. No effect for exposure time up to 140 hours was observed at 50 or 80%RH.

  11. Wall Drying in Hot and Humid Climates

    E-Print Network [OSTI]

    Boone, K.; Weston, T.; Pascual, X.

    2004-01-01T23:59:59.000Z

    WALL DRYING IN HOT AND HUMID CLIMATES Kimdolyn Boone Theresa Weston, PhD Xuaco Pascual Product Development Engineer Building Scientist Field Services Engineer E.I. du Pont de Nemours and Company Richmond, VA ABSTRACT... time based on the varying weather conditions. Constant interior conditions of 70?F and 55% RH were chosen. This corresponds to typical interior temperatures and a high level of moisture production within the house. This was chosen as a worse...

  12. Temperature-Dependent Heterogeneous Efflorescence of Mixed Ammonium Sulfate/Calcium Carbonate Particles

    E-Print Network [OSTI]

    Temperature-Dependent Heterogeneous Efflorescence of Mixed Ammonium Sulfate/Calcium Carbonate sulfate/calcium carbonate microparticles. Deliquescence and efflorescence relative humidities and calcium carbonate and (b) supersaturated with respect to ammonium sulfate and saturated with respect

  13. Temperature and pressure dependences of the Copper-related Green...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    (PL) from tetrapod-like ZnO micro-rods. The temperature dependence of the green emission energy follows the changes in the band gap from 10-200 K, but deviates from...

  14. Ultrahigh humidity sensitivity of graphene oxide

    E-Print Network [OSTI]

    Bi, Hengchang

    Humidity sensors have been extensively used in various fields, and numerous problems are encountered when using humidity sensors, including low sensitivity, long response and recovery times, and narrow humidity detection ...

  15. Active Humidity Control Through Gas-Fired Desiccant Humidity Pump

    E-Print Network [OSTI]

    Novosel, D.; Griffiths, W. C.

    1988-01-01T23:59:59.000Z

    High equipment first cost and high operating costs, if electricity is used to drive such a system, have prohibited the application of active humidity control equipment in comfort conditioning in the past. Instead, passive techniques have been...

  16. QA TG5 UV, temperature and humidity

    Broader source: Energy.gov (indexed) [DOE]

    Si Termination Open circuit Backsheet Multilayer laminated PET Encapusulant EVA (all: fast cure) EVA A Within the shelf life EVA B...

  17. Tower Temperature and Humidity Sensors (TWR) Handbook

    SciTech Connect (OSTI)

    Cook, DR

    2010-02-01T23:59:59.000Z

    Three tall towers are installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility: a 60-meter triangular tower at the Southern Great Plains (SGP) Central Facility (CF), a 21-meter walkup scaffolding tower at the SGP Okmulgee forest site (E21), and a 40-meter triangular tower at the North Slope of Alaska (NSA) Barrow site. The towers are used for meteorological, radiological, and other measurements.

  18. Group 3: Humidity, Temperature, and Voltage

    Broader source: Energy.gov (indexed) [DOE]

    lines, interconnect r ibbons, s older bonds) will likely corrode if exposed to liquid water. * So even if our contacts can survive moisture in the encapsulant they are n ot...

  19. Comparing Wind, Temperature, Pressure, and Humidity

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power Administration would like submit the followingth Lomonosov1Compact

  20. Phase relation between global temperature and atmospheric carbon dioxide

    E-Print Network [OSTI]

    Stallinga, Peter

    2013-01-01T23:59:59.000Z

    The primary ingredient of Anthropogenic Global Warming hypothesis is the assumption that atmospheric carbon dioxide variations are the cause for temperature variations. In this paper we discuss this assumption and analyze it on basis of bi-centenary measurements and using a relaxation model which causes phase shifts and delays.

  1. Improving Comfort in Hot-Humid Climates with a Whole-House Dehumidifier, Windermere, Florida (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-11-01T23:59:59.000Z

    Maintaining comfort in a home can be challenging in hot-humid climates. At the common summer temperature set point of 75 degrees F, the perceived air temperature can vary by 11 degrees F because higher indoor humidity reduces comfort. Often the air conditioner (AC) thermostat set point is lower than the desirable cooling level to try to increase moisture removal so that the interior air is not humid or "muggy." However, this method is not always effective in maintaining indoor relative humidity (RH) or comfort. In order to quantify the performance of a combined whole-house dehumidifier (WHD) AC system, researchers from the U.S. Department of Energy's Building America team Consortium of Advanced Residential Buildings (CARB) monitored the operation of two Lennox AC systems coupled with a Honeywell DH150 TrueDRY whole-house dehumidifier for a six-month period. By using a WHD to control moisture levels (latent cooling) and optimizing a central AC to control temperature (sensible cooling), improvements in comfort can be achieved while reducing utility costs. Indoor comfort for this study was defined as maintaining indoor conditions at below 60% RH and a humidity ratio of 0.012 lbm/lbm while at common dry bulb set point temperatures of 74 degrees -80 degrees F. In addition to enhanced comfort, controlling moisture to these levels can reduce the risk of other potential issues such as mold growth, pests, and building component degradation. Because a standard AC must also reduce dry bulb air temperature in order to remove moisture, a WHD is typically needed to support these latent loads when sensible heat removal is not desired.

  2. 3, 32673299, 2003 Relative humidity and

    E-Print Network [OSTI]

    Deutsches Zentrum f¨ur Luft- und Raumfahrt (DLR), Institut f¨ur Physik der Atmosph¨are (IPA, Sweden 3 Dalhousie University, Department of Physics and Atmospheric Science, Halifax, Nova Scotia

  3. Humidity effects on calibrations of radiation therapy electrometers

    SciTech Connect (OSTI)

    Downton, B.; Walker, S. [Ionizing Radiation Standards, National Research Council of Canada, Bldg. M35, Ottawa, Ontario K1A 0R6 (Canada)

    2012-02-15T23:59:59.000Z

    Purpose: To eliminate variation in electrometer calibration results caused by high humidity and suboptimal connectors on the standard capacitors and to implement hardware that prevents overloading of the input stage of electrometers during calibration. Methods: A humidity-controlled cabinet was installed to provide a low-humidity environment for the standard capacitors. All of the coaxial BNC connections were replaced with Triax (TRB) connectors with the exception of the output from the voltage source. A three-stage RC filter with cascaded RC low-pass sections was designed and tested. Results: The installation of the humidity cabinet resulted in a major improvement in the stability and reproducibility of the electrometer calibration system. For the three years since this upgrade, the Ionizing Radiation Standards (IRS) electrometer calibration results have been consistent regardless of the ambient relative humidity in the lab. The connector replacements improved grounding in the calibration circuit. The three-stage filter allows the voltage at the output to rise in an S-shaped waveform, resulting in a smooth rise of the current through the isolation resistor from zero and back again, with no abrupt transition. For the filter design chosen, 99.99% of the charge is delivered within 6 s. Conclusions: A three-way improvement to the calibration measurement system was successful in eliminating the observed variations, resulting in an electrometer calibration measurement system that is unaffected by humidity and allowing reliable year-round calibrations of any electrometer encountered since the implementation of these changes.

  4. Mean Radiant Cooling in a Hot-Humid Climate

    E-Print Network [OSTI]

    Garrison, M.

    1996-01-01T23:59:59.000Z

    Shaded interior mass walls in a hot-humid climate can be thermally grounded to an earth heat sink under an insulated structure. The mean radiant temperature (MRT) of the shaded and thermally grounded interior mass walls will be cooler in summer than...

  5. The relative importance of deforestation, precipitation change, and temperature sensitivity in determining the

    E-Print Network [OSTI]

    Malhi, Yadvinder

    The relative importance of deforestation, precipitation change, and temperature sensitivity human disturbances ­ two of the most important of which are deforestation and climate change of deforestation as well as the response of species to changes in temperature, precipitation, and atmospheric

  6. Figure S1.Technical diagram of the 1-by-3 tandem differential mobility analyzer (cf. schematic diagram shown in Figure 1). Relative humidity sensors are located at positions RH,

    E-Print Network [OSTI]

    DMAmono, and after the efflorescence test of RH0 - back to RH0 ( = 5). The three rows successively show mobility diameter. Distributions having aqueous particles are shown in red and those having solid particles humidity generation a. Aerosol generation 20 20 Ejector Pump Excess Nebulizer OR Mixing region ORVB VB

  7. Data Center Economizer Contamination and Humidity Study

    E-Print Network [OSTI]

    Shehabi, Arman

    2010-01-01T23:59:59.000Z

    Data Center Economizer Contamination and Humidity Studyoccupants. To investigate contamination levels, particlemethod of collecting contamination readings. The system,

  8. Temperature effects on oil-water relative permeabilities for unconsolidated sands

    SciTech Connect (OSTI)

    Sufi, A.H.

    1983-03-01T23:59:59.000Z

    This study presents an experimental investigation of temperature effects on relative permeabilities of oil- water systems in unconsolidated sands. The fluids used in this study were refined mineral oil and distilled water. A rate sensitivity study was done on residual oil saturation and oil and water relative permeabilities. The temperature sensitivity study of relative permeabilities was conducted in 2 parts. The first was to investigate changes in residual oil saturation with temperature where the cores were 100% saturated with oil at the start of the waterflood. The second part continued the floods for a longer time until the water-cut was virtually 100%. Under these conditions, little change in residual oil saturation was observed with temperature. A study on viscous instabilities also was performed. This verified the existence of viscous fingers during waterflooding. It also was observed that tubing volume after the core could cause fingering, resulting in lower apparent breakthrough oil recoveries.

  9. A Simple Relation between Plasma Density and Temperature in the Scrape-Off Layer of High Recycling Divertors

    E-Print Network [OSTI]

    A Simple Relation between Plasma Density and Temperature in the Scrape-Off Layer of High Recycling Divertors

  10. Temperature-extended Jarzynski relation: Application to the numerical calculation of the surface tension

    E-Print Network [OSTI]

    Christophe Chatelain

    2007-04-05T23:59:59.000Z

    We consider a generalization of the Jarzynski relation to the case where the system interacts with a bath for which the temperature is not kept constant but can vary during the transformation. We suggest to use this relation as a replacement to the thermodynamic perturbation method or the Bennett method for the estimation of the order-order surface tension by Monte Carlo simulations. To demonstrate the feasibility of the method, we present some numerical data for the 3D Ising model.

  11. Phononic pairing glue in cuprates and related high-temperature superconductors

    E-Print Network [OSTI]

    A. S. Alexandrov

    2011-12-16T23:59:59.000Z

    Along with some other researches we have realised that the true origin of high-temperature superconductivity should be found in the strong Coulomb repulsion combined with a significant electronphonon interaction. Both interactions are strong (on the order of 1 eV) compared with the low Fermi energy of doped carries which makes the conventional BCS-Eliashberg theory inapplicable in cuprates and related doped insulators. Based on our recent analytical and numerical results I argue that high-temperature superconductivity from repulsion is impossible for any strength of the Coulomb interaction. Major steps of our alternative polaronic theory are outlined starting from the generic Hamiltonian with the unscreened (bare) Coulomb and electron-phonon interactions accounting for critical temperatures of high-temperature superconductors without any adjustable parameters.

  12. Temperature effects on oil-water relative permeabilities for unconsolidated sands

    SciTech Connect (OSTI)

    Sufi, A.H.

    1982-01-01T23:59:59.000Z

    This study presents an experimental investigation of temperature effects on relative permeabilities of oil-water systems in unconsolidated sands. The fluids used in this study were refined mineral oil and distilled water. A rate sensitivity study was done on residual oil saturation (S/sub or/) and oil and water relative permeabilities. The temperature sensitivity study of relative permeabilities was conducted in two parts. The first was to investigate changes in S/sub or/ with temperature where the cores were 100% saturated with oil at the start of the waterflood. Runs were terminated when the water-cut exceeded 99.8%. For these experiments, S/sub or/ decreased from 0.31 at 70/sup 0/F to 0.09 at 250/sup 0/F. The second part continued the floods for a longer time until the water-cut was virtually 100%. Under these conditions, little change in S/sub or/ was observed with temperature; (0.11 at 70/sup 0/F and 0.085 at 186/sup 0/F). Temperature effects on irreducible water saturations were studied. A small increase in irreducibile water saturation was observed upon increasing the temperature. However, the same magnitude of change was observed by changing the flowrate. Upon increasing the oil flowrate, immediate water production was observed from the core indicating a change in the capillary end effect. By comparing the change in irreducible water saturation with rate and temperature, it was determined that the change was caused mainly by a change in the viscous force across the core. A study on viscous instabilities was also performed. This verified the existence of viscous fingers during waterflooding. It was also observed that tubing volume after the core could cause fingering, resulting in lower apparent breakthrough oil recoveries.

  13. Demand Controlled Ventilation for Improved Humidity Control

    E-Print Network [OSTI]

    Rogers, J. K.

    1996-01-01T23:59:59.000Z

    Demand Controlled Ventilation for Improved Humidity Control James K. Rogers, P.E. One Blacksmith Road Chelmsford, Massachusetts ABSTRACT Recently introduced technology makes it possible to continuously monitor for humidity in numerous... is brought in for ventilation. The high "latent load" inherent in this hot, humid outside air is often the reason for installing excess chiller capacity and the cause of peak power demands. Recent concerns over poor indoor air quality (IAQ) due...

  14. Test Plan to Evaluate the Relationship Among IAQ, Comfort, Moisture, and Ventilation in Humid Climates

    SciTech Connect (OSTI)

    Widder, Sarah H.; Martin, Eric

    2013-03-15T23:59:59.000Z

    This experimental plan describes research being conducted by Pacific Northwest National Laboratory (PNNL), in coordinatation with Florida Solar Energy Center (FSEC), Florida HERO, and Lawrence Berkeley National Laboratory (LBNL) to evaluate the impact of ventilation rate on interior moisture levels, temperature distributions, and indoor air contaminant concentrations. Specifically, the research team will measure concentrations of indoor air contaminants, ventilation system flow rates, energy consumption, and temperature and relative humidity in ten homes in Gainesville, FL to characterize indoor pollutant levels and energy consumption associated with the observed ventilation rates. PNNL and FSEC have collaboratively prepared this experimental test plan, which describes background and context for the proposed study; the experimental design; specific monitoring points, including monitoring equipment, and sampling frequency; key research questions and the associated data analysis approach; experimental logistics, including schedule, milestones, and team member contact information; and clearly identifies the roles and responsibilities of each team in support of project objectives.

  15. Data Center Economizer Contamination and Humidity Study

    E-Print Network [OSTI]

    LBNL-2424E Data Center Economizer Contamination and Humidity Study A. Shehabi, W. Tschudi, A Emerging Technologies Program Data Center Economizer Contamination and Humidity Study Lawrence Berkeley to specifying as little outside air as permissible for human occupants. To investigate contamination levels

  16. Development of a Humid Climate Definition

    E-Print Network [OSTI]

    Hedrick, R. L.; Shirey, D. B.

    1998-01-01T23:59:59.000Z

    The role of humidity in indoor air quality has become of increasing concern in recent years. High indoor humidities can result in microbial growth on building surfaces, resulting in poor indoor air quality, as well as damage to the building and its...

  17. EFFECT OF HUMIDITY LEVEL ON THE CREEP PROPERTIES OF ALLOY 903 AT 650 C

    SciTech Connect (OSTI)

    Dryepondt, Sebastien N [ORNL; Pint, Bruce A [ORNL; Mitchell, Ryan D [Solar Turbines, Inc.

    2012-01-01T23:59:59.000Z

    Alloy 903 (FeNiCo+Nb) is currently used for certain components in industrial gas turbines for low coefficient of thermal expansion applications. A variance in creep behavior for material quality control evaluations suggested a possible effect of moisture level on stress rupture properties. To investigate the role of water vapor on the creep properties of alloy 903, controlled laboratory experiments were conducted at 650 C with 0 to 100% relative humidity. The water content was controlled by flowing dry air through a water bath at a constant temperature. A significant decrease of lifetime was observed in the presence of water vapor, which is likely related to grain boundary embrittlement by the inward diffusion of hydrogen. The increase of the microstructure grain aspect ratio by different forging processes generally improved the rupture lifetime and elongation in air. However, all specimens had reduced lifetime in the presence of water vapor despite the microstructure grain aspect ratios.

  18. MHTGR (modular high-temperature gas-cooled reactor) control: A non-safety related system

    SciTech Connect (OSTI)

    Rodriguez, C.; Swart, F.

    1988-06-01T23:59:59.000Z

    The modular high-temperature gas-cooled reactor (MHTGR) design meets stringent top-level safety regulatory criteria and user requirements that call for high plant availability and no disruption of the public's day to day activities during normal and off-normal operation of the plant. These requirements lead to a plant design that relies mainly on physical properties and passive design features to ensure plant safety regardless of operator actions, plus simplicity and automation to ensure high plant availability and lower cost of operations. The plant does not require safety-related operator actions, and it does not require the control room to be safety related.

  19. Daylight Analysis with Microcomputers for School Buildings in a Hot, Humid Climate 

    E-Print Network [OSTI]

    Leaver, J.; McQueen, T.

    1987-01-01T23:59:59.000Z

    of microcomputer-generated models, especially as they relate to building studies in zones of extreme climate. The hot, humid environment of Louisiana poses unique problems and calls for creative solutions. The use of microcomputers as analytical tools to develop...

  20. Problems associated with the use of urea-formaldehyde foam for residential insulation. Part II. The effects of temperature and humidity on free formaldehyde, extractable formaldehyde, formaldehyde emission, and physical characteristics of the foam

    SciTech Connect (OSTI)

    Schutte, W.C.; Cole, R.S.; Frank, C.W.; Long, K.R.

    1981-02-01T23:59:59.000Z

    Results of testing with two products of urea-formaldehyde based foams are described. Results of three products have previously been reported. Methods for detection and quantitative determination of formaldehyde, design of the experimental chambers, and the procedures are described. Samples of Product D were monitored for about 29 days and samples of Product E were monitored for 60 days in chambers and results are tabulated for formaldehyde emission. Additional tests performed on the two products are: extractable formaldehyde (high and low temperature conditions); free formaldehyde (high and low temperature conditions); comparison of free formaldehyde concentration; density (high and low temperature conditions); shrinkage (high and low temperature conditions). Control panels were constructed to simulate a wall in a home and observations were made and compared with results of the experimental products.

  1. The effect of humidity on the collection efficiencies of two monitoring methods when exposed to a mixture of organic solvents

    E-Print Network [OSTI]

    Rushlow, Lori Ann

    1989-01-01T23:59:59.000Z

    of contaminant and a set humidity level for a two-hour period. The relative humidity levels generated were approximately 10, 50 and 804. Immediately following this two hour period, the samplers were exposed to a predetermined mixture of acetone and toluene... efficiency when exposed to higher humidities than nonoxygenated hydrocarbons, such as toluene, or are there another factors that account for acetone having a larger decrease in collection efficiency? Statistical Analysis The results were entered...

  2. Building America Expert Meeting: Recommended Approaches to Humidity...

    Energy Savers [EERE]

    Building America Expert Meeting: Recommended Approaches to Humidity Control in High Performance Homes Building America Expert Meeting: Recommended Approaches to Humidity Control in...

  3. Infrared behavior of the dispersion relations in high-temperature scalar QED

    E-Print Network [OSTI]

    A. Abada; K. Bouakaz

    2005-10-25T23:59:59.000Z

    We investigate the infrared properties of the next-to-leading-order dispersion relations in scalar quantum electrodynamics at high temperature in the context of hard-thermal-loop perturbation theory. Specifically, we determine the damping rate and the energy for scalars with ultrasoft momenta. We show by explicit calculations that an early external-momentum expansion, before the Matsubara sum is performed, gives exactly the same result as a late one. The damping rate is obtained up to fourth order included in the ultrasoft momentum and the energy up to second order. The damping rate is found sensitive in the infrared whereas the energy not.

  4. Wall Drying in Hot and Humid Climates 

    E-Print Network [OSTI]

    Boone, K.; Weston, T.; Pascual, X.

    2004-01-01T23:59:59.000Z

    Moisture and subsequent mold problems in buildings are a serious and increasing concern for the building industry. Moisture intrusion in buildings is especially pertinent in hot and humid climates because the climate conditions provide only limited...

  5. Observational Tests of the Mass-Temperature Relation for Galaxy Clusters

    E-Print Network [OSTI]

    Donald J. Horner; Richard F. Mushotzky; Caleb A. Scharf

    1999-02-10T23:59:59.000Z

    We examine the relationship between the mass and x-ray gas temperature of galaxy clusters using data drawn from the literature. Simple theoretical arguments suggest that the mass of a cluster is related to the x-ray temperature as $M \\propto T_x^{3/2}$. Virial theorem mass estimates based on cluster galaxy velocity dispersions seem to be accurately described by this scaling with a normalization consistent with that predicted by the simulations of Evrard, Metzler, & Navarro (1996). X-ray mass estimates which employ spatially resolved temperature profiles also follow a $T_x^{3/2}$ scaling although with a normalization about 40% lower than that of the fit to the virial masses. However, the isothermal $\\beta$-model and x-ray surface brightness deprojection masses follow a steeper $\\propto T_x^{1.8-2.0}$ scaling. The steepness of the isothermal estimates is due to their implicitly assumed dark matter density profile of $\\rho(r) \\propto r^{-2}$ at large radii while observations and simulations suggest that clusters follow steeper profiles (e.g., $\\rho(r) \\propto r^{-2.4}$).

  6. SYSTEMATIC CONTINUUM ERRORS IN THE Ly{alpha} FOREST AND THE MEASURED TEMPERATURE-DENSITY RELATION

    SciTech Connect (OSTI)

    Lee, Khee-Gan, E-mail: lee@astro.princeton.edu [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States)

    2012-07-10T23:59:59.000Z

    Continuum fitting uncertainties are a major source of error in estimates of the temperature-density relation (usually parameterized as a power-law, T {proportional_to} {Delta}{sup {gamma}-1}) of the intergalactic medium through the flux probability distribution function (PDF) of the Ly{alpha} forest. Using a simple order-of-magnitude calculation, we show that few percent-level systematic errors in the placement of the quasar continuum due to, e.g., a uniform low-absorption Gunn-Peterson component could lead to errors in {gamma} of the order of unity. This is quantified further using a simple semi-analytic model of the Ly{alpha} forest flux PDF. We find that under(over)estimates in the continuum level can lead to a lower (higher) measured value of {gamma}. By fitting models to mock data realizations generated with current observational errors, we find that continuum errors can cause a systematic bias in the estimated temperature-density relation of ({delta}({gamma})) Almost-Equal-To -0.1, while the error is increased to {sigma}{sub {gamma}} Almost-Equal-To 0.2 compared to {sigma}{sub {gamma}} Almost-Equal-To 0.1 in the absence of continuum errors.

  7. Variation in rectal temperature, respiratory rate, and pulse rate of cattle as related to variations in solar radiation, air temperature, wind velocity, and vapor pressure

    E-Print Network [OSTI]

    Quazi, Mohammad Fazlur Rahim

    1955-01-01T23:59:59.000Z

    VARIATION IN RECTAL TEMPERATURE, RESPIRATORY RATE, AND PULSE RATE GF CATTLE AS RELATED TO VARIATIONS IN SOLAR RADIATION, AIR TEMPERATURE, WIND VELOCITY, AND VAPOR PRESSURE A Dissertation By Mohammad Fazlur Rahim Quazi Approved as to style... Dissertation By Mohammad Fazlur Rahim tyiazi Submitted to the Graduate School of the Agricultural and Mechanical College of Texas in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY May 1955 Major Subject: Genetics ? ?4...

  8. Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles

    E-Print Network [OSTI]

    Xu, K.; Liu, M.; Wang, G.; Wang, Z.

    2007-01-01T23:59:59.000Z

    temperature at supply air temperature setpoint. Mechanical cooling is always required when outside air temperature is higher than the supply air temperature setpoint. Generally the supply air temperature setpoint is set at 55°F for space humidity control...

  9. Response of tropical sea surface temperature, precipitation, and tropical cyclone-related variables to changes in global and local forcing

    E-Print Network [OSTI]

    Sobel, Adam

    A single-column model is used to estimate the equilibrium response of sea surface temperature (SST), precipitation, and several variables related to tropical cyclone (TC) activity to changes in both local and global forcing. ...

  10. Voltage sensing systems and methods for passive compensation of temperature related intrinsic phase shift

    DOE Patents [OSTI]

    Davidson, James R. (Idaho Falls, ID); Lassahn, Gordon D. (Idaho Falls, ID)

    2001-01-01T23:59:59.000Z

    A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. In crystals that introduce a phase differential attributable to temperature, a compensating crystal is provided to cancel the effect of temperature on the phase differential of the input beam. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

  11. Exploring high temperature phenomena related to post-detonation using an electric arc

    SciTech Connect (OSTI)

    Dai, Z. R., E-mail: dai1@llnl.gov; Crowhurst, J. C.; Grant, C. D.; Knight, K. B.; Tang, V.; Chernov, A. A.; Cook, E. G.; Lotscher, J. P.; Hutcheon, I. D. [Lawrence Livermore National Laboratory, Livermore, California 94551-0808 (United States)

    2013-11-28T23:59:59.000Z

    We report a study of materials recovered from a uranium-containing plasma generated by an electric arc. The device used to generate the arc is capable of sustaining temperatures of an eV or higher for up to 100??s. Samples took the form of a 4??m-thick film deposited onto 8 pairs of 17??m-thick Cu electrodes supported on a 25??m-thick Kapton backing and sandwiched between glass plates. Materials recovered from the glass plates and around the electrode tips after passage of an arc were characterized using scanning and transmission electron microscopy. Recovered materials included a variety of crystalline compounds (e.g., UO{sub 2}, UC{sub 2}, UCu{sub 5},) as well as mixtures of uranium and amorphous glass. Most of the materials collected on the glass plates took the form of spherules having a wide range of diameters from tens of nanometers to tens of micrometers. The composition and size of the spherules depended on location, indicating different chemical and physical environments. A theoretical analysis we have carried out suggests that the submicron spherules presumably formed by deposition during the arc discharge, while at the same time the glass plates were strongly heated due to absorption of plasma radiation mainly by islands of deposited metals (Cu, U). The surface temperature of the glass plates is expected to have risen to ?2300?K thus producing a liquefied glass layer, likely diffusions of the deposited metals on the hot glass surface and into this layer were accompanied by chemical reactions that gave rise to the observed materials. These results, together with the compact scale and relatively low cost, suggest that the experimental technique provides a practical approach to investigate the complex physical and chemical processes that occur when actinide-containing material interacts with the environment at high temperature, for example, during fallout formation following a nuclear detonation.

  12. Vertical distribution of larval stages of the horn fly, Haematobia irritans irritans (L.), in relation to manure pat temperature gradients

    E-Print Network [OSTI]

    March, Philip Anderson

    1981-01-01T23:59:59.000Z

    VERTICAL DISTRISUTION OF LARVAL STAGES OF THE HORN FLY, HAEMATOBIA IRRITANS IRRITANS (L. ), IN RELATION TO MANURE PAT TEMPERATURE GRADIENTS A Thesis by PHILIP ANDERSON MARCH Submitted to the Graduate College of Texas AijM University... in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE May 1981 Major Subject: Entomology VERTICAL DISTRIBUTION OF LARVAL STAGES OF THE HORN FLY, HAEMATOBIA IRRITANS IRRITANS (L. ), IN RELATION TO MANURE PAT TEMPERATURE GRADIENTS...

  13. HUMID AIR TURBINE CYCLE TECHNOLOGY DEVELOPMENT PROGRAM

    SciTech Connect (OSTI)

    Richard Tuthill

    2002-07-18T23:59:59.000Z

    The Humid Air Turbine (HAT) Cycle Technology Development Program focused on obtaining HAT cycle combustor technology that will be the foundation of future products. The work carried out under the auspices of the HAT Program built on the extensive low emissions stationary gas turbine work performed in the past by Pratt & Whitney (P&W). This Program is an integral part of technology base development within the Advanced Turbine Systems Program at the Department of Energy (DOE) and its experiments stretched over 5 years. The goal of the project was to fill in technological data gaps in the development of the HAT cycle and identify a combustor configuration that would efficiently burn high moisture, high-pressure gaseous fuels with low emissions. The major emphasis will be on the development of kinetic data, computer modeling, and evaluations of combustor configurations. The Program commenced during the 4th Quarter of 1996 and closed in the 4th Quarter of 2001. It teamed the National Energy Technology Laboratory (NETL) with P&W, the United Technologies Research Center (UTRC), and a subcontractor on-site at UTRC, kraftWork Systems Inc. The execution of the program started with bench-top experiments that were conducted at UTRC for extending kinetic mechanisms to HAT cycle temperature, pressure, and moisture conditions. The fundamental data generated in the bench-top experiments was incorporated into the analytical tools available at P&W to design the fuel injectors and combustors. The NETL then used the hardware to conduct combustion rig experiments to evaluate the performance of the combustion systems at elevated pressure and temperature conditions representative of the HAT cycle. The results were integrated into systems analysis done by kraftWork to verify that sufficient understanding of the technology had been achieved and that large-scale technological application and demonstration could be undertaken as follow-on activity. An optional program extended the experimental combustion evaluations to several specific technologies that can be used with HAT technology. After 5 years of extensive research and development, P&W is pleased to report that the HAT Technology Development Program goals have been achieved. With 0 to 10 percent steam addition, emissions achieved during this program featured less than 8 ppm NO{sub x}, less than 16 ppm CO, and unburned hydrocarbons corrected to 15 percent O{sub 2} for an FT8 engine operating between 0 and 120 F with 65 to 100 percent power at any day.

  14. Lanthanide-halide based humidity indicators

    DOE Patents [OSTI]

    Beitz, James V. (Hinsdale, IL); Williams, Clayton W. (Chicago, IL)

    2008-01-01T23:59:59.000Z

    The present invention discloses a lanthanide-halide based humidity indicator and method of producing such indicator. The color of the present invention indicates the humidity of an atmosphere to which it is exposed. For example, impregnating an adsorbent support such as silica gel with an aqueous solution of the europium-containing reagent solution described herein, and dehydrating the support to dryness forms a substance with a yellow color. When this substance is exposed to a humid atmosphere the water vapor from the air is adsorbed into the coating on the pore surface of the silica gel. As the water content of the coating increases, the visual color of the coated silica gel changes from yellow to white. The color change is due to the water combining with the lanthanide-halide complex on the pores of the gel.

  15. Safety First Safety Last Safety Always Summer in Minnesota means high humidity and sunny, hot

    E-Print Network [OSTI]

    Minnesota, University of

    Safety First Safety Last Safety Always Summer in Minnesota means high humidity and sunny, hot days. · Heat stroke is life threatening! Symptoms include high body temperature, red and dry skin, rapid before you get thirsty. Adequate fluid intake is the biggest key. Cool (not ice cold) water is the best

  16. Humidity Implications for Meeting Residential Ventilation Requirements

    E-Print Network [OSTI]

    1 LBNL-62182 Humidity Implications for Meeting Residential Ventilation Requirements Iain S. Walker for Meeting Residential Ventilation Requirements ABSTRACT In 2003 ASHRAE approved the nation's first residential ventilation standard, ASHRAE Standard 62.2. Because meeting this standard can significantly change

  17. Coil Condensation Detection For Humidity Control

    E-Print Network [OSTI]

    Kaneb, Charles Peckitt

    2014-05-12T23:59:59.000Z

    of an enthalpy economizer. A spreadsheet simulation of enthalpy economizer use showed that the savings available are heavily dependent on the ability to avoid its use on very hot, humid days. A newly-designed condensation sensor was developed for this project...

  18. The effect of temperature and humidity on respirator fit

    E-Print Network [OSTI]

    Niekerk, Gary

    1986-01-01T23:59:59.000Z

    of atmosphere- supplying respirator is the self-contained breathing apparatus (SCBA). These devices are not connected to a stationary air source, such as a compressor. Instead, air is supplied from a compressed air or oxygen tank carried on the person...

  19. Correlating Humidity-Dependent Ionically Conductive Surface Area with Transport Phenomena in Proton-Exchange Membranes

    SciTech Connect (OSTI)

    He, Qinggang; Kusoglu, Ahmet; Lucas, Ivan T.; Clark, Kyle; Weber, Adam Z.; Kostecki, Robert

    2011-08-01T23:59:59.000Z

    The objective of this effort was to correlate the local surface ionic conductance of a Nafion? 212 proton-exchange membrane with its bulk and interfacial transport properties as a function of water content. Both macroscopic and microscopic proton conductivities were investigated at different relative humidity levels, using electrochemical impedance spectroscopy and current-sensing atomic force microscopy (CSAFM). We were able to identify small ion-conducting domains that grew with humidity at the surface of the membrane. Numerical analysis of the surface ionic conductance images recorded at various relative humidity levels helped determine the fractional area of ion-conducting active sites. A simple square-root relationship between the fractional conducting area and observed interfacial mass-transport resistance was established. Furthermore, the relationship between the bulk ionic conductivity and surface ionic conductance pattern of the Nafion? membrane was examined.

  20. PDO-Related Heat and Temperature Budget Changes in a Model of the North Pacific JORDAN T. DAWE

    E-Print Network [OSTI]

    Thompson, LuAnne

    in the Pacific. The PDO index shows significant correlations with a wide variety of climate indices, including between a variety of Indian and Pacific tropical climate indices and the PDO. Since atmospheric signalsPDO-Related Heat and Temperature Budget Changes in a Model of the North Pacific JORDAN T. DAWE

  1. Effect of Humidity on the Composition of Isoprene Photooxidation Secondary Organic Aerosol

    SciTech Connect (OSTI)

    Nguyen, Tran B.; Roach, Patrick J.; Laskin, Julia; Laskin, Alexander; Nizkorodov, Serguei

    2011-07-18T23:59:59.000Z

    The effect of relative humidity (RH) on the composition and concentrations of gas-phase products and secondary organic aerosol (SOA) generated from the photooxidation of isoprene under high-NOx conditions was investigated. The yields of most gas-phase products were the same regardless of initial water vapor concentration with exception of hydroxyacetone and glycolaldehyde, which were considerably affected by RH. A significant change was observed in the SOA composition, with many unique condensed-phase products formed under humid (90% RH) vs. dry (<2% RH) conditions, without any observable effect on the rate and extent of the SOA mass growth.

  2. Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates

    E-Print Network [OSTI]

    Im, P.; Haberl, J.

    This paper presents the analysis of the energy savings potential in K-5 schools in hot and humid climates. For the analysis, an existing K-5 school in Central Texas was selected as a case study school, and the building energy related data...

  3. Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates 

    E-Print Network [OSTI]

    Im, P.; Haberl, J.

    2008-01-01T23:59:59.000Z

    This paper presents the analysis of the energy savings potential in K-5 schools in hot and humid climates. For the analysis, an existing K-5 school in Central Texas was selected as a case study school, and the building energy related data...

  4. THE LOW-TEMPERATURE THRESHOLD FOR PINK SALMON EGGS IN RELATION TO A PROPOSED HYDROELECTRIC INSTALLATION

    E-Print Network [OSTI]

    Alaska would alter the seasonal pattern of stream temperatures and pose a threat to the natural (now the Alaska Power Administration) started feasibil- ity studies on a hydroelectric installation of the water from Grace Creek through a hydroelectric plant and back into Grace Creek about 1.2 km from tide

  5. An Analytical Model for Tropical Relative Humidity DAVID M. ROMPS

    E-Print Network [OSTI]

    Romps, David M.

    the distribution of water vapor will change with warming. Water vapor is the atmosphere's most powerful greenhouse gas, and changes in its distribution can have significant implications for radiative forcing. A first

  6. Theoretical relation between water flow rate in a vertical fracture and rock temperature in the surrounding massif

    E-Print Network [OSTI]

    Maréchal, Jean-Christophe

    2010-01-01T23:59:59.000Z

    A steady-state analytical solution is given describing the temperature distribution in a homogeneous massif perturbed by cold water flow through a discrete vertical fracture. A relation is derived to express the flow rate in the fracture as a function of the temperature measured in the surrounding rock. These mathematical results can be useful for tunnel drilling as it approaches a vertical cold water bearing structure that induces a thermal anomaly in the surrounding massif. During the tunnel drilling, by monitoring this anomaly along the tunnel axis one can quantify the flow rate in the discontinuity ahead before intersecting the fracture. The cases of the Simplon, Mont Blanc and Gotthard tunnels (Alps) are handled with this approach which shows very good agreement between observed temperatures and the theoretical trend. The flow rates before drilling of the tunnel predicted with the theoretical solution are similar in the Mont Blanc and Simplon cases, as well as the flow rates observed during the drilling....

  7. R&D on an Ultra-Thin Composite Membrane for High-Temperature Operation in PEMFC. Final Report

    SciTech Connect (OSTI)

    Yuh, C.-Y.

    2003-10-06T23:59:59.000Z

    FuelCell Energy developed a novel high-temperature proton exchange membrane for PEM fuel cells for building applications. The laboratory PEM fuel cell successfully operated at 100-400{supdegree}C and low relative humidity to improve CO tolerance, mitigate water and thermal management challenges, and reduce membrane cost. The developed high-temperature membrane has successfully completed 500h 120C endurance testing.

  8. Moisture performance of sealed attics in the mixed-humid climate

    SciTech Connect (OSTI)

    Boudreaux, Philip R [ORNL; Pallin, Simon B [ORNL; Jackson, Roderick K [ORNL

    2013-12-01T23:59:59.000Z

    Oak Ridge National Laboratory studied 8 homes in the mixed-humid climate, 4 with vented attics and 4 with sealed attics. ORNL wanted to understand the moisture performance of the sealed attic and how it affected the interior environment. We found that the attic and interior of sealed attic homes were more humid than the attic and interior observed in vented attic homes. This is due to the lack of ventilation in the sealed attic. Historically attics have been vented to dehumidify the attic and interior of the home. A sealed attic design greatly reduces the venting potential and thus this drying pathway and can cause elevated interior moisture over a vented attic home. Despite the elevated attic and interior moisture in the sealed attic homes, so far no mold or material degradation has been found. The roof sheathing moisture content has stayed below 20%, indicating low potential for material degradation. Also the relative humidity at the roof sheathing has stayed within the ASHRAE 160 design criteria except for a short time during the 2011/2012 winter. This was due to a combination of the sealed attic design (minimal venting to the outside) and the duct work not being operated in the attic which usually provides a dehumidification pathway. It was also found that when the humidity was controlled using the HVAC system, it resulted in 7% more cooling energy consumption. In the mixed-humid climate this reduces the cost effectiveness of the sealed attic design as a solution for bringing ducts into a semi-conditioned space. Because of this we are recommending the other alternatives be used to bringing ducts into the conditioned space in both new construction and retrofit work in the mixed-humid climate.

  9. Design of a Green Demo Building in a Hot and Humid City in China

    E-Print Network [OSTI]

    Hammer, W.; Kluz, E.; Sonan, A.; Jiang, Y.; Bacall, A.; Jones, B.

    2006-01-01T23:59:59.000Z

    of temperature, humidity, and wind are analyzed to identify the effective strategies for heating, cooling, and ventilation. Advanced green design practice and technologies are introduced into the design. In terms of design standards, the proposed design.... For example, to improve ventilation effects and avoid excessive solar heat gains, the architectural design is modified by introducing a ventilation well, upper-lower window placement, bioclimatic facades, light shelf, and wing walls. In addition, many...

  10. Integrated Hygrothermal Performance of Building Envelopes and Systems in Hot and Humid Climates

    E-Print Network [OSTI]

    Karagiozis, A. N.; Desjarlais, A.; Salonvaara, M.

    2000-01-01T23:59:59.000Z

    Technology Center VTT Building Technology, Oak Ridge National Laboratory, Oak Ridge National Laboratory, Espoo, Finland Building Technology Center, Oak Ridge, Tennessee, US Oak Ridge, Tennessee, US ABSTRACT In hot and humid climates the interior... the long-term hygrothermal performance of the building to various vapor control and thermal insulation strategies while subjecting the exterior boundary to real weather data (including temperature, vapor pressure, wind speed and orientation, solar...

  11. AN OVERVIEW OF BUILDING AMERICA INDUSTRIALIZED HOUSING PARTNERSHIP (BAIHP) ACTIVITIES IN HOT-HUMID CLIMATES

    E-Print Network [OSTI]

    Chandra, S.; Parker, D.; Sherwin, J.; Colon, C.; Fonorow, K.; Stroer, D.; Martin, E.; McIlvaine, J.; Chasar, D.; Moyer, N.; Thomas-Rees, S.; Hoak, D.; Beal, D.; Gil, C.

    tightness, pressure mapping, outside airflow measurement, static pressure, temperature drop, and exhaust fan air flow measurement. Once these tests have been completed, the homes are given a HERS Index rating calculated by FSEC?s EnergyGauge ? software... and technical assistance activities for new housing. Hot-humid climate efforts described here include: Systems research : NightCool ? A hybrid cooling and dehumidification strategy employing radiative cooling and desiccant materials. Interior Duct...

  12. On the relation between electron temperatures in the O+ and O++ zones in high-metallicity HII regions

    E-Print Network [OSTI]

    L. S. Pilyugin; J. M. Vilchez; T. X. Thuan

    2006-05-29T23:59:59.000Z

    We suggest a new way to establish the relation between the electron temperature t3 within the [OIII] zone and the electron temperature t2 within the [OII] zone in high-metallicity (12+log(O/H) > 8.25) HII regions. The t2 - t3 diagram is constructed by applying our method to a sample of 372 HII regions. We find that the correlation between t2 and t3 is tight and can be approximated by a linear expression. The new t2 - t3 relation can be used to determine t2 and accurate abundances in high-metallicity HII regions with a measured t3. It can also be used in conjunction with the ff relation for the determination of t3 and t2 and oxygen abundances in high-metallicity HII regions where the [OIII]4363 auroral line is not detected. The derived t2 - t3 relation is independent of photoionization models of HII regions.

  13. The relation of octane number, compression ratio, and exhaust temperature in the gasoline engine

    E-Print Network [OSTI]

    Jentsch, Donald George

    1951-01-01T23:59:59.000Z

    of this effect was aided by the use of two test engines, one a single cylinder variable compression ratio experimental engine, and the other a standard industrial V-8 automotive engine. The follosing discussion is given to define "fuel octane ratings...", by C. D. Hiller p S. A. E. Transactions, Vol. 1, No. 19 January 19479 pp. 98. 24. "Evaluating Fuels for &igh Compression Engines", by N. Roensch and J. C. Hughes, Automotive Industries, November 1, 1950, pp. 50. THE RELATION OF OCTANE NM3ER...

  14. Can ASHRAE Standard 62-1989 Requirements be Satisfied while Maintaining Moisture Control using Stock HVAC Equipment in Hot, Humid Climates?

    E-Print Network [OSTI]

    Turner, S. C.

    1996-01-01T23:59:59.000Z

    energy costs. Increased ventilation rates create real capital and operating costs for building owners and operators, with implications beyond energy costs relating to increased ventilation requirements. In hot, humid climates, increased ventilation rates...

  15. AC System Equipment Specification, Installation and Operational Options for Improved Indoor Humidity Control

    E-Print Network [OSTI]

    Shirey, D. B.

    of 80?F (26.7?C) dry-bulb temperature and 67?F (19.4?C) wet-bulb temperature air entering the indoor unit (AHRI 2006), the equipment SHRs range from 0.67 to 0.8. Thus, the dehumidification fraction (one minus SHR) varies from 0.2 (20%) to 0.33 (33... Building Systems in Hot and Humid Climates, Plano, TX, December 15-17, 2008 Figure 3. Latent Capacity Degradation with Supply Air Fan Overrun at Reduced Air Flow compressor on cycle (Shirey et al. 2006). The plotted lines are results from a...

  16. PRESERVATION OF H2 PRODUCTION ACTIVITY IN NANOPOROUS LATEX COATINGS OF RHODOPSEUDOMONAS PALUSTRIS CGA009 DURING DRY STORAGE AT AMBIENT TEMPERATURES

    SciTech Connect (OSTI)

    Milliken, C.; Piskorska, M.; Soule, T.; Gosse, J.; Flickinger, M.; Smith, G.; Yeager, C.

    2012-08-27T23:59:59.000Z

    To assess the applicability of latex cell coatings as an "off-the-shelf' biocatalyst, the effect of osmoprotectants, temperature, humidity and O{sub 2} on preservation of H{sub 2} production in Rhodopseudomonas palustris coatings was evaluated. Immediately following latex coating coalescence (24 h) and for up to 2 weeks of dry storage, rehydrated coatings containing different osmoprotectants displayed similar rates of H{sub 2} production. Beyond 2 weeks of storage, sorbitol- treated coatings lost all H{sub 2} production activity, whereas considerable H{sub 2} production was still detected in sucrose- and trehalose-stabilized coatings. The relative humidity level at which the coatings were stored had a significant impact on the recovery and subsequent rates of H{sub 2} production. After 4 weeks storage under air at 60% humidity, coatings produced only trace amounts of H{sub 2} (0-0.1% headspace accumulation), whereas those stored at <5% humidity retained 27-53% of their H{sub 2} production activity after 8 weeks of storage. When stored in argon at <5% humidity and room temperature, R. palustris coatings retained full H{sub 2} production activity for 3 months, implicating oxidative damage as a key factor limiting coating storage. Overall, the results demonstrate that biocatalytic latex coatings are an attractive cell immobilization platform for preservation of bioactivity in the dry state.

  17. american temperature record: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    temperature, pressure, cloud, humidity and wind. The calibrated soil temperature data recorded at 1 foot30 cm and 4 foot100 cm depth 125 Call for Papers NEW Graduate...

  18. Impact of substrate temperature on the incorporation of carbon-related defects and mechanism for semi-insulating behavior in GaN grown by molecular beam epitaxy

    E-Print Network [OSTI]

    Armstrong, A; Poblenz, C; Green, D S; Mishra, U K; Speck, J S; Ringel, S A

    2006-01-01T23:59:59.000Z

    GaN grown by molecular beam epitaxy and codoped with carbon and silicon were investigated for substratesubstrate temperature on the incorporation of carbon-related defects and mechanism for semi-insulating behavior in GaN

  19. argentine humid pampa: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    XI, Universit de 197 Humidity effects on ,,001... BaTiO3 single crystal surface water adsorption L. J. Qiao,1,a Engineering Websites Summary: with kinetic cutoff energy...

  20. A tropical grammar : an architectural grammar for hot humid climates

    E-Print Network [OSTI]

    Beamish, Anne, 1954-

    1993-01-01T23:59:59.000Z

    This thesis considers the viability of an architectural grammar based on traditional Caribbean architecture as an aid to designing climatically responsive architecture in hot humid climates. It argues that since traditional ...

  1. Effect of Humidity on the Composition of Isoprene Photooxidation...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    effect on the rate and extent of the SOA mass growth. Citation: Nguyen TB, PJ Roach, J Laskin, A Laskin, and S Nizkorodov.2011."Effect of Humidity on the Composition of...

  2. Three Case Studies: Moisture Control in a Hot, Humid Climate

    E-Print Network [OSTI]

    French, W. R.

    2002-01-01T23:59:59.000Z

    as analysis of the problems, and recommendations for correction. Each of these projects would be classified an airconditioned building in a hot, humid climate, and subject to the problems and design issues concomitant with these types of projects. The first...

  3. Relationalism

    E-Print Network [OSTI]

    Edward Anderson

    2014-07-15T23:59:59.000Z

    This article contributes to the debate of the meaning of relationalism and background independence, which has remained of interest in theoretical physics from Newton versus Leibniz through to foundational issues for today's leading candidate theories of quantum gravity. I contrast and compose the substantially different Leibniz--Mach--Barbour (LMB) and Rovelli--Crane (RC) uses of the word `relational'. Leibniz advocated primary timelessness and Mach that `time is to be abstracted from change'. I consider 3 distinct viewpoints on Machian time: Barbour's, Rovelli's and my own. I provide four expansions on Barbour's taking configuration space to be primary: to (perhaps a weakened notion of) phase space, categorizing, perspecting and propositioning. Categorizing means considering not only object spaces but also the corresponding morphisms and then functors between such pairs. Perspecting means considering the set of subsystem perspectives; this is an arena in which the LMB and Rovelli approaches make contact. By propositioning, I mean considering the set of propositions about a physical (sub)system. I argue against categorization being more than a formal pre-requisite for quantization in general; however, perspecting is a categorical operation, and propositioning leads one to considering topoi, with Isham and Doering's work represents one possibility for a mathematically sharp implementation of propositioning. Further applications of this article are arguing for Ashtekar variables as being relational in LMB as well as just the usually-ascribed RC sense, relationalism versus supersymmetry, string theory and M-theory. The question of whether scale is relational is also considered, with quantum cosmology in mind.

  4. A Guide to the Measurement of Humidity. 1-68. 1996. London, Institute of Measurement and Control.

    E-Print Network [OSTI]

    , Nathan Williamson, and Mark H. Huff. 2002. Foliar moisture content of Pacific Northwest vegetation measurements. Journal Of Geophysical Research-Atmospheres 106, no. D24:33623-33648. Anderson, Mark L. 1967 Management 8. 383 #12;Aphalo, P. J. and P. G. Jarvis. 1991. Do Stomata Respond to Relative Humidity. Plant

  5. What Global Warming Looks Like The July 2010 global map of surface temperature anomalies (Figure 1), relative to the average

    E-Print Network [OSTI]

    What Global Warming Looks Like The July 2010 global map of surface temperature anomalies (Figure 1 anomalies an example of what we can expect global warming to look like? Maps of temperature anomalies, such as Figure 1, are useful for helping people understand the role of global warming in extreme events

  6. Shut Down Schedule Optimization with Outdoor Humidity Level

    E-Print Network [OSTI]

    Chen, H.; Deng, S.; Turner, W. D.; Claridge, D. E.; Clingenpeel, K.

    2006-01-01T23:59:59.000Z

    areas such as Portland and San Diego exhibit a large amount of hours wherein this scheme could be implemented. Table 4. Number of Hours That Satisfy AHU Shutdown Criteria for 16 U.S. Cities Hours that Fit All Three Criteria Location Total Hours... 6155 3055 886 3941 San Diego 6317 3331 853 4184 Portland 7167 3544 1035 4579 For hot and humid climates, such as Houston, the air is often too humid in the summer, and the methodology will work best during the fall, spring, and winter as seen...

  7. Alternate Air Delivery Systems for Hot and Humid Climates

    E-Print Network [OSTI]

    Wallace, M.

    1996-01-01T23:59:59.000Z

    -zone units in the Harris County Criminal Courts Building in Houston, one of the most hot and humid climates in the United States, as well as in several other facilities. This paper will discuss the adoption of ASHRAE 62, its effects on VAV systems, and how...

  8. Studies Related to the Oregon State University High Temperature Test Facility: Scaling, the Validation Matrix, and Similarities to the Modular High Temperature Gas-Cooled Reactor

    SciTech Connect (OSTI)

    Richard R. Schultz; Paul D. Bayless; Richard W. Johnson; William T. Taitano; James R. Wolf; Glenn E. McCreery

    2010-09-01T23:59:59.000Z

    The Oregon State University (OSU) High Temperature Test Facility (HTTF) is an integral experimental facility that will be constructed on the OSU campus in Corvallis, Oregon. The HTTF project was initiated, by the U.S. Nuclear Regulatory Commission (NRC), on September 5, 2008 as Task 4 of the 5 year High Temperature Gas Reactor Cooperative Agreement via NRC Contract 04-08-138. Until August, 2010, when a DOE contract was initiated to fund additional capabilities for the HTTF project, all of the funding support for the HTTF was provided by the NRC via their cooperative agreement. The U.S. Department of Energy (DOE) began their involvement with the HTTF project in late 2009 via the Next Generation Nuclear Plant project. Because the NRC interests in HTTF experiments were only centered on the depressurized conduction cooldown (DCC) scenario, NGNP involvement focused on expanding the experimental envelope of the HTTF to include steady-state operations and also the pressurized conduction cooldown (PCC). Since DOE has incorporated the HTTF as an ingredient in the NGNP thermal-fluids validation program, several important outcomes should be noted: 1. The reference prismatic reactor design, that serves as the basis for scaling the HTTF, became the modular high temperature gas-cooled reactor (MHTGR). The MHTGR has also been chosen as the reference design for all of the other NGNP thermal-fluid experiments. 2. The NGNP validation matrix is being planned using the same scaling strategy that has been implemented to design the HTTF, i.e., the hierarchical two-tiered scaling methodology developed by Zuber in 1991. Using this approach a preliminary validation matrix has been designed that integrates the HTTF experiments with the other experiments planned for the NGNP thermal-fluids verification and validation project. 3. Initial analyses showed that the inherent power capability of the OSU infrastructure, which only allowed a total operational facility power capability of 0.6 MW, is inadequate to permit steady-state operation at reasonable conditions. 4. To enable the HTTF to operate at a more representative steady-state conditions, DOE recently allocated funding via a DOE subcontract to HTTF to permit an OSU infrastructure upgrade such that 2.2 MW will become available for HTTF experiments. 5. Analyses have been performed to study the relationship between HTTF and MHTGR via the hierarchical two-tiered scaling methodology which has been used successfully in the past, e.g., APEX facility scaling to the Westinghouse AP600 plant. These analyses have focused on the relationship between key variables that will be measured in the HTTF to the counterpart variables in the MHTGR with a focus on natural circulation, using nitrogen as a working fluid, and core heat transfer. 6. Both RELAP5-3D and computational fluid dynamics (CD-Adapco’s STAR-CCM+) numerical models of the MHTGR and the HTTF have been constructed and analyses are underway to study the relationship between the reference reactor and the HTTF. The HTTF is presently being designed. It has ¼-scaling relationship to the MHTGR in both the height and the diameter. Decisions have been made to design the reactor cavity cooling system (RCCS) simulation as a boundary condition for the HTTF to ensure that (a) the boundary condition is well defined and (b) the boundary condition can be modified easily to achieve the desired heat transfer sink for HTTF experimental operations.

  9. alternating temperature preculture: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    A; Moi, L 2013-01-01 3 Warm Humid Climate: Methodology to Study Air Temperature Distribution: Mobile Phones Base Stations as Viable Alternative for Fixed Points Texas A&M...

  10. Corrosion-induced degradation of GaAs PHEMTs under operation in high humidity conditions

    E-Print Network [OSTI]

    Hisaka, Takayuki

    We have comprehensively investigated the degradation mechanism of AlGaAs/InGaAs pseudomorphic high-electron-mobility transistors (PHEMTs) under operation in high humidity conditions. PHEMTs degradation under high humidity ...

  11. Control Humidity With Single-Duct, Single-Zone, Constant Air Volume System

    E-Print Network [OSTI]

    Chen, H.; Deng, S.; Bruner, H. L.; Claridge, D. E.

    2000-01-01T23:59:59.000Z

    ), which turned this inefficient, humid lecture hall into a comfortable learning environment. This case study also explores other possibilities to solve the humidity control problem with single-duct, single-zone constant air volume systems....

  12. ASSESSMENT OF THE EFFECTIVENESS AND ENERGY EFFICIENCY OF HUMIDITY CONTROL APPROACHES IN VACANT FLORIDA HOMES

    E-Print Network [OSTI]

    Cummings, J. B.; Withers, C. R.

    In a hot and humid climate such as Florida, “snowbirds” that leave their homes for extended summer periods need guidance on effective and energy efficient methods of humidity control. Experiments were performed in seven residences to evaluate...

  13. The design, construction, and instrumentation of a chamber to study heat, mass, and momentum transfer from humid air to metal under conditions of frosting and free convection

    E-Print Network [OSTI]

    Hutchison, James P

    1961-01-01T23:59:59.000Z

    THE DESIGN? CONSTRUCTION? AND INSTRUMENTATION OF A CEAMSER TO STUDY HEAT, MASS? AND MOSNTUM TRANSFER FROM HUMID AIR TO METAL UNDER CONDITIONS OF FROSTING AND FREE CONVECTION A Thesis By James P. Hutchison Submitted to the Graduate School... temperatures a cryogenic pump wss necessary. The sire of the pump was computed on the basis of maintaining a one degree Fahrenheit drop of the coolant temperature through the supply systms. The greatest heat load on the supply system being 3718 BTU per hour...

  14. Synthesis of novel polyimides for the testing of structure-processing and property relations when used to form high temperature polymer matrices

    E-Print Network [OSTI]

    Tschen Molina, Francisco

    2007-04-25T23:59:59.000Z

    constants [17], spectroscopic properties [18,19] and molecular order to mention a few [20,21]. The addition of fluorine atoms incorporated into the polyimide, the chemical structure affects many properties that can add superior properties to the polymer...SYNTHESIS OF NOVEL POLYIMIDES FOR THE TESTING OF STRUCTURE- PROCESSING AND PROPERTY RELATIONS WHEN USED TO FORM HIGH TEMPERATURE POLYMER MATRICES A Thesis by FRANCISCO TSCHEN MOLINA Submitted to the Office of Graduate...

  15. Museum Archive Dehumidification in Hot and Humid Climates

    E-Print Network [OSTI]

    Browning, B. K.

    2004-01-01T23:59:59.000Z

    . The capacity of the dehumidifiers was controlled by building energy management and control system (EMCS) switching on a dehumidifier when the humidity exceeded the set point and switching it off below the set point. The EMCS also detected dehumidifier... failure and switch on the backup dehumidifier. The EMCS was set to lead/lag the dehumidifiers and switch the lead unit every week. History The operator of the system found a dehumidifier down within the first 60 days. The contractor...

  16. Eliminating Humidity and Condensation Problems in University Dormitories - Case Study

    E-Print Network [OSTI]

    Claridge, D.; Turner, W. D.; Zhu, Y.; Chen, H.; Bruner, H., Jr.; Hugghins, J.; Deng, S.

    2002-01-01T23:59:59.000Z

    , building construction, and the Energy Management Control System (EMCS). This paper presents the investigation and follow-up efforts, which identified reasons and corrective measures for the high humidity levels in the living areas of Mc... handling units (AHUs) and fan-coil units (FCUs), exhaust systems, and the building energy management control systems (EMCS). Facility information is presented in Table 1. Extensive airflow and water flow measurements were taken on each of the outside...

  17. Performance Evaluation of a Hot-Humid Climate Community

    SciTech Connect (OSTI)

    Osser, R.; Kerrigan, P.

    2012-02-01T23:59:59.000Z

    Project Home Again is a development in New Orleans, LA created to provide new homes to victims of Hurricane Katrina. Building Science Corporation acted as a consultant for the project, advocating design strategies for durability, flood resistance, occupant comfort, and low energy use while maintaining cost effectiveness. These techniques include the use of high density spray foam insulation, LoE3 glazing, and supplemental dehumidification to maintain comfortable humidity levels without unnecessary cooling.

  18. Appeared in Sensors and Actuators B: Chemical, vol. 114, no. 1, pp. 254-262, 30 March 2006 Compliant and Low-cost Humidity Sensors using

    E-Print Network [OSTI]

    Sitti, Metin

    inexpensively on various types of nano-porous polymer membranes such as polycarbonate, cellulose acetate. Keywords: Humidity sensor; Nanoporous membrane; Polycarbonate; Shadow mask; 1. INTRODUCTION Humidity humidity sensors. Resistive humidity sensors usually consist of a moisture-sensitive, conductive material

  19. Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate, Cocoa, Florida (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-04-01T23:59:59.000Z

    Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season. ?

  20. Humidity Control Systems for Civil Buildings in Hot Summer and Cold Winter Zone in China 

    E-Print Network [OSTI]

    Yu, X.

    2006-01-01T23:59:59.000Z

    ICEBO2006, Shenzhen, China Control Systems for Energy Efficiency and Comfort, Vol. V-3-1 Humidity Control Systems for Civil Buildings in Hot Summer and Cold Winter Zone in China Xiaoping Yu Doctoral Candidate Chongqing University of Science... the sensor-controller to run when humidity reaches a set level. A dehumidifying ventilator is particularly effective if the humidity source is in our basement. Dehumidifying ventilators don't recover heat but they use less electricity than heat pump...

  1. Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

    SciTech Connect (OSTI)

    Munk, Jeffrey D [ORNL; Gehl, Anthony C [ORNL; Jackson, Roderick K [ORNL

    2012-04-01T23:59:59.000Z

    Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate t

  2. ARM Energy Balance Bowen Ratio (EBBR) station: surf. heat flux and related data, 30-min

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Cook, David

    The Energy Balance Bowen Ratio (EBBR) system produces 30-min estimates of the vertical fluxes of sensible and latent heat at the local surface. Flux estimates are calculated from observations of net radiation, soil surface heat flux, and the vertical gradients of temperature and relative humidity. Meteorological data collected by the EBBR are used to calculate bulk aerodynamic fluxes, which are used in the Bulk Aerodynamic Technique (BA) EBBR value-added product (VAP) to replace sunrise and sunset spikes in the flux data. A unique aspect of the system is the automatic exchange mechanism (AEM), which helps to reduce errors from instrument offset drift.

  3. Simulation and Optimization of the Temperature and Humidity Independent Control Showcase

    E-Print Network [OSTI]

    Hou, H.; Yu, L.; Wan, X.; Chen, H.

    2006-01-01T23:59:59.000Z

    in the Hamburg Public Records Office[J]. Museum Management and Curatorship, 1999,18 (2):193-204 [2] Tim Padfield. a cooled display case. http:// www.padfield.org/tim/cfys/coolcase/coolcase.pdf [3] Tim Padfield. A cooled display case for George Washington...

  4. Simulation and Optimization of the Temperature and Humidity Independent Control Showcase 

    E-Print Network [OSTI]

    Hou, H.; Yu, L.; Wan, X.; Chen, H.

    2006-01-01T23:59:59.000Z

    in the Hamburg Public Records Office[J]. Museum Management and Curatorship, 1999,18 (2):193-204 [2] Tim Padfield. a cooled display case. http:// www.padfield.org/tim/cfys/coolcase/coolcase.pdf [3] Tim Padfield. A cooled display case for George Washington... Chinese) [11] Patankar S V. Numerical heat transfer and fluid flow[M]. Washington DC, 1980. [12] Leonard BP. A stable and accurate convective modeling procedure based on quadratic upstream interpolation. Computer methods in applied mechanics...

  5. Temperature, humidity and air flow in the emplacement drifts using convection and dispersion transport models

    E-Print Network [OSTI]

    Danko, G.

    2010-01-01T23:59:59.000Z

    Repository . Journal of Nuclear Technology, July, Vol. 163,Mountain . Journal of Nuclear Technology, July, Vol. 163.Mountain . Journal of Nuclear Technology, July, Vol. 163,

  6. The determination of interference levels of temperature and humidity on continuous monitoring of diisocyanate

    E-Print Network [OSTI]

    Ryan, Donald Arden

    1982-01-01T23:59:59.000Z

    to TDI, usually as a result of accidental spills, will almost invariably produce respiratory irritation. Often eye, nose and throat irritations are the first clinical manifest- ations. Dry cough accompanied by chest pain or tight- ness follows.... The cough is characteristically worse in the evening or at ni. ght, often:. obscuring its occupational cause. Chest X-rays taken during the acute stage are usually interpreted as normal, although increased markings and patchy infiltrates are occasion...

  7. Temperature, humidity and air flow in the emplacement drifts using convection and dispersion transport models

    E-Print Network [OSTI]

    Danko, G.

    2010-01-01T23:59:59.000Z

    stages after waste emplacement, the coupled, in-drift heat,waste emplacement, forced ventilation removes the majority of the heatheat and moisture transport processes. domain includes the waste

  8. Critical Plane Analysis of Wall Assembly in a Hot, Humid Climate

    E-Print Network [OSTI]

    Turner, S. C.

    2000-01-01T23:59:59.000Z

    or examples are available. This paper presents this detail for a typical light commercial wall assembly, and provides the basis for analysis of any envelope assembly in hot and humid climates. Analysis of an envelope assembly in hot and humid climates seeks...

  9. Effects of humidity on storing big sagebrush seed. Forest Service research paper

    SciTech Connect (OSTI)

    Welch, B.L.

    1996-12-01T23:59:59.000Z

    Data support the conclusion that big sagebrush seed should not be stored in environments having humidities above 32 to 40 percent. Some humidities may even dry seed to a greater degree than when first placed in storage. Force-air seed driers should not heat big sagebrush seed over 60 degrees C.

  10. Effects of ambient humidity on the energy use of air conditioning equipment

    E-Print Network [OSTI]

    White, Justin George

    2010-01-01T23:59:59.000Z

    temperatures for high ambient wet bulb period of 6AM Sep 01,10 Figure 3.1: Comparison of dry bulb and relative humiditytemperatures for low ambient wet bulb period of 6AM Jan 06,

  11. Fast Response and High Sensitivity ZnO/glass Surface Acoustic Wave Humidity Sensors Using Graphene Oxide Sensing Layer

    E-Print Network [OSTI]

    Xuan, Weipeng; He, Mei; Meng, Nan; He, Xingli; Wang, Wenbo; Chen, Jinkai; Shi, Tianjin; Hasan, Tawfique; Xu, Zhen; Xu, Yang; Luo, J. K.

    2014-11-26T23:59:59.000Z

    We report ZnO/glass surface acoustic wave (SAW) humidity sensors with high sensitivity and fast response using graphene oxide sensing layer. The frequency shift of the sensors is exponentially correlated to the humidity change, induced mainly...

  12. The Effect of Humidity on the Reliability of a Surface Micromachined Microengine

    SciTech Connect (OSTI)

    Dugger, M.T.; Eaton, W.P.; Irwin, L.W.; Miller, S.L.; Miller, W.M.; Smith, N.F.; Tanner, D.M.; Walraven, J.A.

    1999-02-02T23:59:59.000Z

    Humidity is shown to be a strong factor in the wear of rubbing surfaces in polysilicon micromachines. We demonstrate that very low humidity can lead to very high wear without a significant change in reliability. We show that the volume of wear debris generated is a function of the humidity in an air environment. As the humidity decreases, the wear debris generated increases. For the higher humidity levels, the formation of surface hydroxides may act as a lubricant. The dominant failure mechanism has been identified as wear. The wear debris has been identified as amorphous oxidized silicon. Large slivers (approximately 1 micron in length) of debris observed at the low humidity level were also amorphous oxidized silicon. Using transmission electron microscopy, we observed that the wear debris forms spherical and rod-like shapes. We compared two surface treatment processes: a fluorinated si- lane chain, (FITl) and supercritical C02 dried (SCC02). The microengines using the SCC02 process were found to be less reliable than those released with the FIX process under two humidity levels.

  13. Facile fabrication of three-dimensional mesoporous Si/SiC composites via one-step magnesiothermic reduction at relative low temperature

    SciTech Connect (OSTI)

    Jiang, Zhihang; Ma, Yongjun [State Key Laboratory Cultivation Base for Nonmetal Composites and Functional Materials, Southwest University of Science and Technology, Mianyang 621010 (China); Zhou, Yong [Eco-materials and Renewable Energy Research Center (ERERC), School of Physics, National Lab of Solid State Microstructure, ERERC, Nanjing University, Nanjing 210093 (China); Hu, Shanglian [School of Life Science and Engineering, Southwest University of Science and Technology, Mianyang 621010 (China); Han, Chaojiang [State Key Laboratory Cultivation Base for Nonmetal Composites and Functional Materials, Southwest University of Science and Technology, Mianyang 621010 (China); Pei, Chonghua, E-mail: peichonghua@swust.edu.cn [State Key Laboratory Cultivation Base for Nonmetal Composites and Functional Materials, Southwest University of Science and Technology, Mianyang 621010 (China)

    2013-10-15T23:59:59.000Z

    Graphical abstract: - Highlights: • The Si/SiC composites were synthesized by one-step magnesiothermic reduction. • The mesoporous composites have a high specific surface area (655.7 m{sup 2} g{sup ?1}). • The composites exhibited a strong photoluminescence and better biocompatibility. • The mechanisms of formation and photoluminescence of sample were discussed. - Abstract: By converting modified silica aerogels to the corresponding silicon/silicon carbide (Si/SiC) without losing its nanostructure, three-dimensional mesoporous (3DM) Si/SiC composites are successfully synthesized via one-step magnesothermic reduction at relative low temperature (650 °C). The phase composition and microstructure of the resulting samples are measured by X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDX), Raman spectra, scanning electron microscopy (SEM) and transmission electron microscopy (TEM). N{sub 2}-sorption isotherms results show that the products have high Brunauer–Emmett–Teller (BET) specific surface areas (up to 656 m{sup 2} g{sup ?1}) and narrow pore-size distributions (1.5–30 nm). The composites exhibit a strong photoluminescence (PL) in blue-green light region (peak centered at 533 nm). We have set out work on the biocompatibility and enhancing PL of samples. As a result of excellent performances of the composites, it can be expected to have significant application in optoelectronics, biosensors, biological tracer and so on.

  14. The Effects of Test Temperature, Temper, and Alloyed Copper on the Hydrogen-Controlled Crack Growth Rate of an Al-Zn-Mg-(Cu) Alloy

    SciTech Connect (OSTI)

    G.A. Young, Jr.; J.R. Scully

    2000-09-17T23:59:59.000Z

    The hydrogen embrittlement controlled stage II crack growth rate of AA 7050 (6.09 wt.% Zn, 2.14 wt% Mg, 2.19 wt.% Cu) was investigated as a function of temper and alloyed copper level in a humid air environment at various temperatures. Three tempers representing the underaged, peak aged, and overaged conditions were tested in 90% relative humidity (RH) air at temperatures between 25 and 90 C. At all test temperatures, an increased degree of aging (from underaged to overaged) produced slower stage II crack growth rates. The stage II crack growth rate of each alloy and temper displayed Arrhenius-type temperature dependence with activation energies between 58 and 99 kJ/mol. For both the normal copper and low copper alloys, the fracture path was predominantly intergranular at all test temperatures (25-90 C) in each temper investigated. Comparison of the stage II crack growth rates for normal (2.19 wt.%) and low (0.06 wt.%) copper alloys in the peak aged and overaged tempers showed the beneficial effect of copper additions on stage II crack growth rate in humid air. In the 2.19 wt.% copper alloy, the significant decrease ({approx} 10 times at 25 C) in stage II crack growth rate upon overaging is attributed to an increase in the apparent activation energy for crack growth. IN the 0.06 wt.% copper alloy, overaging did not increase the activation energy for crack growth but did lower the pre-exponential factor, {nu}{sub 0}, resulting in a modest ({approx} 2.5 times at 25 C) decrease in crack growth rate. These results indicate that alloyed copper and thermal aging affect the kinetic factors that govern stage II crack growth rate. Overaged, copper bearing alloys are not intrinsically immune to hydrogen environment assisted cracking but are more resistant due to an increased apparent activation energy for stage II crack growth.

  15. Photooxidation of Alpha-Pinene at High Relative Humidity in the...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    by PTR-MS and their yields include formaldehyde (5 + 1%), formic acid (2.5 + 1.4%), methanol (0.6 + 0.3%), acetaldehyde (3.9 + 1.7%), acetic acid (10 + 2%), acetone (11.5 +...

  16. An Experimental Evaluation of the Time Response of a Duct-Mounted Relative Humidity Sensors 

    E-Print Network [OSTI]

    Joshi, S.N.; Pate, M.B.; Nelson, R.M.; House, J.H.; Klaassen, C.J.

    2007-01-01T23:59:59.000Z

    This work is aimed towards the development of an artificially intelligent search algorithm used in conjunction with an Auto Associative Neural Network (AANN) to help locate and reconstruct faulty sensor inputs in control systems. The AANN can...

  17. Modeling Effects of Relative Humidity, Moisture, and Extreme Environmental Conditions on Power Electronic Performance

    E-Print Network [OSTI]

    Lehman, Brad

    this knowledge during the design phase can improve the reliability of the equipment, thereby reducing failures, certain equipment may contain devices highly sensitive to environmental conditions. Understanding and dropping maintenance costs. Some of the environmental conditions affecting electronic equipment and systems

  18. MHK ISDB/Sensors/Relative Humidity Sensor 3445 | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere I Geothermal Pwer Plant Jump to:LandownersLuther, Oklahoma: EnergyMAREC Jump to:2 -MHKMHKMHKMHKMHKMHKMHK

  19. Lower-tropospheric humidity: climatology, trends and the relation to the ITCZ

    E-Print Network [OSTI]

    Raible, Christoph C.

    parts of the atmosphere via direct (absorption, emission and reflection) and indirect (cloud cover and convective heating) effects (e.g. Sherwood, 2010). The modulation of radiative transfer itself is back are important for the hydrological cycle and the global radiation energy budget (e.g. Ruckstuhl et al., 2007

  20. Posters A Comparison of Model-Simulated Relative Humidity with Satellite-Derived Cloudiness

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible forPortsmouth/Paducah Project Office PressPostdoctoraldecadal observations71 Posters A

  1. Victoria & Albert Museum- Medieval & Renaissance Galleries: A Passive Approach to Humidity Control

    E-Print Network [OSTI]

    Lerpiniere, A.; Bingham, M.; Walker, S.

    2010-01-01T23:59:59.000Z

    The new Medieval & Renaissance Galleries employ a passive approach to environmental control. The design exploits the massive nature of the building and uses sophisticated control techniques to minimise variations in humidity in the galleries...

  2. Sensors and Actuators B 114 (2006) 254262 Compliant and low-cost humidity nanosensors using

    E-Print Network [OSTI]

    Lin, Qiao

    2006-01-01T23:59:59.000Z

    of nanoporous polymer membranes such as polycarbonate, cellulose acetate, and nylon membranes. The nanosensor. On the other hand, capacitive humidity sensors are based on non-conducting materials, which make up

  3. An Analysis of Building Envelope Upgrades for Residential Energy Efficiency in Hot and Humid Climates

    E-Print Network [OSTI]

    Malhotra, M.; Haberl, J.

    This paper presents the results of the analyses of various envelope upgrades for residential energyefficiency in hot and humid climates. The building components considered for the upgrades include: building shape, construction type, roof...

  4. Technical and Economic Analysis of Solar Cooling Systems in a Hot and Humid Climate

    E-Print Network [OSTI]

    Moaveni, H.

    The aim of this paper is to promote efficient and cost effective implementation of advanced solar cooling systems and techniques for the hot and humid climates cities in the United States. After an introduction of basic principles, the development...

  5. A passive cooling design for multifamily residences [sic] in hot, humid climates

    E-Print Network [OSTI]

    Tang, Joseph C

    1983-01-01T23:59:59.000Z

    People living in hot, humid climates suffer either from extremely uncomfortable weather conditions or from the great cost of air-conditioning systems for maintaining comfort. Most of the available passive cooling techniques ...

  6. Danish Building Research Institute, Aalborg University 2009 Humidity as a control parameter for

    E-Print Network [OSTI]

    Ventilation system.....................................................................................11 for ventilation Phase 2: Development and testing of ventilation strategies in the laboratory Alireza Afshari Niels C. Bergsøe #12;Title Humidity as a control parameter for ventilation Subtitle Phase 2: Development

  7. Enthalpy Wheels Come of Age: Applying Energy Recovery Ventilation to Hospitality Venues in Hot, Humid Climate

    E-Print Network [OSTI]

    Wellford, B. W.

    2000-01-01T23:59:59.000Z

    ventilation to hospitality venues in hot, humid climates need not be complex. This paper proposes guidelines that can facilitate application of the technology by specifiers or other construction professionals. These guidelines address evaluation of typical...

  8. Integrated Hygrothermal Performance of Building Envelopes and Systems in Hot and Humid Climates 

    E-Print Network [OSTI]

    Karagiozis, A. N.; Desjarlais, A.; Salonvaara, M.

    2000-01-01T23:59:59.000Z

    In hot and humid climates the interior and exterior environmental loads that building envelopes must respond to are larger than many other climatic conditions. Moisture-originated failures in low-rise residential buildings have put a significant...

  9. An Analysis of Building Envelope Upgrades for Residential Energy Efficiency in Hot and Humid Climates 

    E-Print Network [OSTI]

    Malhotra, M.; Haberl, J.

    2006-01-01T23:59:59.000Z

    This paper presents the results of the analyses of various envelope upgrades for residential energyefficiency in hot and humid climates. The building components considered for the upgrades include: building shape, construction ...

  10. Applications of Commercial Heat Pump Water Heaters in Hot, Humid Climates

    E-Print Network [OSTI]

    Johnson, K. F.; Shedd, A. C.

    Heat pump water heaters can provide high-efficiency water heating and supplemental space cooling and dehumidification in commercial buildings throughout the United States. They are particularly attractive in hot, humid areas where cooling loads...

  11. Expert Meeting: Recommended Approaches to Humidity Control in High Performance Homes

    SciTech Connect (OSTI)

    Rudd, A.

    2013-07-01T23:59:59.000Z

    The topic of this Building America expert meeting was 'Recommended Approaches to Humidity Control in High Performance Homes,' which was held on October 16, 2012, in Westford, MA, and brought together experts in the field of residential humidity control to address modeling issues for dehumidification. The presentations and discussions centered on computer simulation and field experience with these systems, with the goal of developing foundational information to support the development of a Building America Measure Guideline on this topic.

  12. Role of Wind in Vernacular Architecture of Hot and Humid Region of Iran

    E-Print Network [OSTI]

    Najafabadi, R. A.; Daneshvar, K.; Pakseresht, K.; Pooryousefzadeh, S.

    2006-01-01T23:59:59.000Z

    the total framework which underlies architecture. Vernacular architecture in hot and humid regions of Iran has strong bonds with local climate. Shenasil, Taremi and Wind towers are the features that have developed according to climatic considerations... of different climatic elements on the vernacular architecture with a focus on humidity and air currents. Then, natural ventilation and the architectural elements involving it will be discussed. Finally, the wind towers of the region...

  13. An Analysis of Maximum Residential Energy Efficiency in Hot and Humid Climates 

    E-Print Network [OSTI]

    Malhotra, M.; Haberl, J. S.

    2006-01-01T23:59:59.000Z

    Systems in Hot and Humid Climates, Orlando, Florida, July 24-26, 2006 Methodology 1. Development of the Basecase Simulation Model 2. Analysis of Energy Saving Measures 3. Development of the Maximum Energy-Efficient House 4. Economic Analysis DOE-2 Input...AN ANALYSIS OF MAXIMUM RESIDENTIAL ENERGY EFFICIENCY IN HOT AND HUMID CLIMATES Mini Malhotra Graduate Research Assistant Jeff Haberl, Ph.D., P.E. Professor/Associate Director Energy Systems Laboratory, Texas A&M University College...

  14. Plant and microbial controls on nitrogen retention and loss in a Humid Tropical Forest

    SciTech Connect (OSTI)

    Templer, P.; Silver, W.; Pett-Ridge, J.; DeAngelis, K.M.; Firestone, M.K.

    2009-09-15T23:59:59.000Z

    Humid tropical forests are generally characterized by the lack of nitrogen (N) limitation to net primary productivity, yet paradoxically have high potential for N loss. We conducted an intensive field experiment with {sup 15}NH{sub 4} and {sup 15}NO{sub 3} additions to highly weathered tropical forest soils to determine the relative importance of N retention and loss mechanisms. Over half of all the NH{sub 4}{sup +} produced from gross mineralization was rapidly converted to NO{sub 3}{sup -} during the process of gross nitrification. During the first 24 h plant roots took up 28 % of the N mineralized, dominantly as NH{sub 4}{sup +}, and were a greater sink for N than soil microbial biomass. Soil microbes were not a significant sink for added {sup 15}NH{sub 4}{sup +} or {sup 15}NO{sub 3}{sup -} during the first 24 hr, and only for {sup 15}NH{sub 4}{sup +} after 7 d. Patterns of microbial community composition, as determined by Terminal Restriction Fragment Length Polymorphism analysis, were weakly, but significantly correlated with nitrification and denitrification to N{sub 2}O. Rates of dissimilatory NO{sub 3}{sup -} reduction to NH{sub 4}{sup +} (DNRA) were high in this forest, accounting for up to 25 % of gross mineralization and 35 % of gross nitrification. DNRA was a major sink for NO{sub 3}{sup -} which may have contributed to the lower rates of N{sub 2}O and leaching losses. Despite considerable N conservation via DNRA and plant NH{sub 4}{sup +} uptake, the fate of approximately 45% of the NO{sub 3}{sup -} produced and 22% of the NH{sub 4}{sup +} produced were not measured in our fluxes, suggesting that other important pathways for N retention and loss (e.g., denitrification to N{sub 2}) are important in this system. The high proportion of mineralized N that was rapidly nitrified and the fates of that NO{sub 3}{sup -} highlight the key role of gross nitrification as a proximate control on N retention and loss in humid tropical forest soils. Furthermore, our results demonstrate the importance of the coupling between DNRA and plant uptake of NH{sub 4}{sup +} as a potential N conserving mechanism within tropical forests.

  15. Low temperature cryoprobe

    DOE Patents [OSTI]

    Sungaila, Zenon F. (Orland Park, IL)

    1989-01-01T23:59:59.000Z

    A portable, hand held probe usable within a small confine to produce a point source of nitrogen or helium at a relatively constant temperature of 77 degrees Kelvin.

  16. Global temperatures and sunspot numbers. Are they related? Yes, but non linearly. A reply to Gil-Alana et al. (2014)

    E-Print Network [OSTI]

    Scafetta, Nicola

    2014-01-01T23:59:59.000Z

    Gil-Alana et al. (Physica A: 396, 42-50, 2014) compared the sunspot number record and the temperature record and found that they differ: the sunspot number record is characterized by a dominant 11-year cycle while the temperature record appears to be characterized by a singularity or pole in the spectral density function at the zero frequency. Consequently, they claimed that the two records are characterized by substantially different statistical fractional models and rejected the hypothesis that sun influences significantly global temperatures. I show that: (1) the "singularity" or "pole" in the spectral density function of the global surface temperature at the "zero" frequency does not exist - it is a typical misinterpretation that discrete power spectra of non-stationary signals can suggest; (2) appropriate continuous periodograms clarify the issue and also show a signature of the 11-year solar cycle (amplitude <0.1 K), which since 1850 has an average period of about 10.4 year, and of many other natural...

  17. Determination of the 1%, 2.5%, and 5% occurrences of extreme dew-point temperatures and mean coincident dry-bulb temperatures

    SciTech Connect (OSTI)

    Colliver, D.G.; Zhang, H.; Gates, R.; Priddy, T. [Univ. of Kentucky, Lexington, KY (United States)

    1995-12-31T23:59:59.000Z

    The purpose of ASHRAE Research Project RP-754 was to find the outdoor design occurrences of extreme dew-point temperature and the corresponding mean coincident dry-bulb temperature for a large number of locations in North America. Thirty years of data (1961--1990) were used for 239 US locations, and the last 30 years of hourly data available (typically 1960--1989) were used for 143 Canadian locations. Tables are given that present the 1%, 2.5%, and 5% extreme summertime occurrences of dew-point temperatures and corresponding values of humidity ratios and the mean coincident dry-bulb (MCDB) temperature for the period of record. A map that shows the general geographical trends for the spatial distribution of the design dew-point values is also presented. Comparisons are provided between interpolation techniques to fill missing data, different weather data sets, and methods of calculating different definitions of extreme design and mean coincident data. Results are also reported of a comparison to evaluate the difference in humidity ratios between that calculated from the extreme design dry-bulb temperature and mean coincident wet-bulb temperature, versus that calculated from the extreme design dew-point temperature and the MCDB. It was found that the method of extreme dew point with MCDB had a higher humidity ratio that was on the average (for the 1% case and the 239 US locations) 0.00564 lb/lb larger than the humidity ratio found with the other method.

  18. Relation between hydrogen isotopic ratios of bone collagen and rain

    SciTech Connect (OSTI)

    Cormie, A.B.; Schwarcz, H.P. (McMaster Univ., Hamilton, Ontario (Canada)); Gray, J. (Univ. of Alberta, Edmonton (Canada))

    1994-01-01T23:59:59.000Z

    The hydrogen isotopic value ([delta]D) of deer bone collagen is related to both [delta]D of rain during the growing season and growing season relative humidity (RH). With correction for the effects of RH, bone [delta]D is related to growing season rain [delta]D in a simple manner with a slope of 1.0. This indicates that, with RH correction, there are no additional sources of bias in the [delta]D of bone due to unaccounted for biologic or climatic effects. Due to a low sensitivity of bone [delta]D to RH effects, both yearly and growing season rain [delta]D can be estimated with considerable accuracy (R = 0.97 and R = 0.96) from bone collagen [delta]D and [delta][sup 15]N. Here, [delta][sup 15]N is used to correct bone [delta]D for the effects of RH. From these estimates of rain [delta]D, it may then be possible to evaluate temperature since the [delta]D of rain primarily reflects local temperature. Therefore, the measurement of bone collagen [delta]D has good potential for evaluating paleoclimates.

  19. SISGR: Theoretically relating the surface composition of Pt alloys to their performance as the electrocatalysts of low-temperature fuel cells

    SciTech Connect (OSTI)

    Wang, Guofeng

    2010-12-31T23:59:59.000Z

    The main goal of this project is to gain fundamental knowledge about the relation between surface composition and catalytic performance of Pt alloy catalysts for oxygen reduction reaction (ORR). Specific objectives are: to develop and improve a first-principles based multiscale computation approach to simulating surface segregation phenomena in Pt alloy surfaces; to evaluate the surface electronic structure and catalytic activity of Pt alloy catalysts and; to relate the surface composition to the catalytic performance of Pt alloy catalysts.

  20. Temperature, Temperature, Earth, geotherm for

    E-Print Network [OSTI]

    Treiman, Allan H.

    Temperature, Temperature, Earth, geotherm for total global heat flow Venus, geotherm for total global heat flow, 500 Ma #12;Temperature, Temperature, #12;Earth's modern regional continental geotherms Venusian Geotherms, 500 Ma Temperature, Temperature, After Blatt, Tracy, and Owens Petrology #12;Ca2Mg5Si8

  1. Enhancing Performance Contracts: Integrating IAQ Solutions in Hot & Humid Climates

    E-Print Network [OSTI]

    Turner, S. C.

    1998-01-01T23:59:59.000Z

    marketplace. STANDARDS Building codes typically establish required minimums for ventilation and some other IAQ- related elements of performance contracts. k addition, widely accepted industry standards are often referenced in building codes, and become... for accomplishing that work. Often, establishing a clearer basis for performance expectations with respect to JAQ is complicated by the age of a facility or the capacity of its existing heating, ventilating, and air conditioning WAC) systems. Buildings...

  2. Ventilation Requirements in Hot Humid Iain S. Walker and Max H. Sherman

    E-Print Network [OSTI]

    LBNL-59889 Ventilation Requirements in Hot Humid Climates Iain S. Walker and Max H. Sherman residential ventilation standard, ASHRAE Standard 62.2. Meeting this standard in new construction requires the use of mechanical ventilation, which in turn can often significantly increase the latent load faced

  3. QUALIT DES ENSILAGES DE MAS GRAIN HUMIDE PRSERVS PAR L'ACIDE PROPIONIQUE

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    product) and acetic (0,1-0,3 per cent) acids are produced by carbohydrate fermentation. The silage p maïs grain humide, la fermentation des glucides entraîne une pro- duction notable d'acides lactique (0 degradative change is practically inhi- bited after 3 to 8 months : in our assays, lactic and acetic acids

  4. Matrix penetration in the bulk:In uence of humidity: Morphological analysis of wood welding

    E-Print Network [OSTI]

    Dalang, Robert C.

    Matrix penetration in the bulk:In uence of humidity: Morphological analysis of wood welding.pichelin@b .ch Context: Wood can be welded using linear vibration welding tech- niques similar to the ones in plastic and metal industry[1] . Wood welding allows bonding strength similar to glued joints. However, due

  5. Distributed Performance of Polymer Electrolyte Fuel Cells under Low-Humidity Conditions

    E-Print Network [OSTI]

    Mench, Matthew M.

    ,a, * M. M. Mench,a, **,z S. Cleghorn,b and U. Beuscherb a Fuel Cell Dynamics and Diagnostics LaboratoryDistributed Performance of Polymer Electrolyte Fuel Cells under Low-Humidity Conditions Q. Dong, Pennsylvania 16802, USA b W.L. Gore & Associates, Gore Fuel Cell Technologies, Incorporated, Elkton, Maryland

  6. 4B.1 IMPACTS OF HUMIDITY-CORRECTED SONDE DATA ON TOGA COARE ANALYSES

    E-Print Network [OSTI]

    Wang, Junhong

    occurred over the entire depth of sounding profile, but were largest at low levels. Based on extensive humidity sensor. This error affects the entire sounding profile, increases with the age of the sonde at several key sites generally reported hu- midities too dry. In contrast, the sounding systems around 10 N

  7. Small Residence Multizone Modeling with Partial Conditioning for Energy Effieiency in Hot and Humid Climates

    E-Print Network [OSTI]

    Andolsun, Simge

    2013-07-30T23:59:59.000Z

    The purpose of this study is to reduce the energy cost of the low-income households in the hot and humid climates of the U.S. and thereby to help them afford comfortable homes. In this perspective, a new HVAC energy saving strategy, i.e. “partial...

  8. Energy Wheel Performance and Optimization Opportunities for SDVAV AHU's In a Hot & Humid Climate

    E-Print Network [OSTI]

    Zhao, J.; Wang, L.; Watt, J.

    2012-01-01T23:59:59.000Z

    The HVAC system accounts for 30 to 50 percent of a typical building's energy consumption; in hot & humid climates it is closer to the upper end of that range. Implementing effective energy saving measures for the building HVAC system can reduce...

  9. Energy Wheel Performance and Optimization Opportunities for SDVAV AHU's In a Hot & Humid Climate 

    E-Print Network [OSTI]

    Zhao, J.; Wang, L.; Watt, J.

    2012-01-01T23:59:59.000Z

    The HVAC system accounts for 30 to 50 percent of a typical building's energy consumption; in hot & humid climates it is closer to the upper end of that range. Implementing effective energy saving measures for the building HVAC system can reduce...

  10. Development of a High-Performance Office Building Simulation Model for a Hot and Humid Climate 

    E-Print Network [OSTI]

    Cho, S.; Haberl, J.

    2009-01-01T23:59:59.000Z

    applicable to office buildings in hot and humid climates and to develop a high-performance (maximum energy-efficient) building model that only uses technologies readily available in the contemporary market. The high-performance model showed 48% total energy...

  11. Small Residence Multizone Modeling with Partial Conditioning for Energy Effieiency in Hot and Humid Climates 

    E-Print Network [OSTI]

    Andolsun, Simge

    2013-07-30T23:59:59.000Z

    The purpose of this study is to reduce the energy cost of the low-income households in the hot and humid climates of the U.S. and thereby to help them afford comfortable homes. In this perspective, a new HVAC energy saving strategy, i.e. “partial...

  12. Bio-Char Soil Management on Highly Weathered Soils in the Humid Tropics

    E-Print Network [OSTI]

    Lehmann, Johannes

    therefore have to be applied each year to sustain soil productivity. Management of black carbon (C36 Bio-Char Soil Management on Highly Weathered Soils in the Humid Tropics Johannes Lehmann1), ColombiaQ1 CONTENTS 36.1 Bio-Char Management and Soil Nutrient Availability

  13. Monitoring groundwater storage changes in the highly1 seasonal humid tropics: validation of GRACE measurements2

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    1 Monitoring groundwater storage changes in the highly1 seasonal humid tropics: validation of GRACE the seasonality and trend in groundwater storage associated with intensive groundwater19 abstraction for dry to 2007) groundwater storage changes21 (GWS) correlate well (r=0.77 to 0.93, p-value

  14. Appropriate Conservation Measures for Single-Family Buildings in Hot, Humid Climates 

    E-Print Network [OSTI]

    McLain, H. A.; MacDonald, J. M.; Goldenberg, D.

    1985-01-01T23:59:59.000Z

    The effectiveness of a number of energy conservation measures for homes located in hot, humid climates was analyzed using the DOE-2.1B building simulation model. Measures having the greatest benefits to the homeowner are predicted to be the addition...

  15. A KNOWLEDGE DISCOVERY STRATEGY FOR RELATING SEA SURFACE TEMPERATURES TO FREQUENCIES OF TROPICAL STORMS AND GENERATING PREDICTIONS OF HURRICANES UNDER 21ST-CENTURY GLOBAL WARMING SCENARIOS

    SciTech Connect (OSTI)

    Race, Caitlin [University of Minnesota; Steinbach, Michael [University of Minnesota; Ganguly, Auroop R [ORNL; Semazzi, Fred [North Carolina State University; Kumar, Vipin [University of Minnesota

    2010-01-01T23:59:59.000Z

    The connections among greenhouse-gas emissions scenarios, global warming, and frequencies of hurricanes or tropical cyclones are among the least understood in climate science but among the most fiercely debated in the context of adaptation decisions or mitigation policies. Here we show that a knowledge discovery strategy, which leverages observations and climate model simulations, offers the promise of developing credible projections of tropical cyclones based on sea surface temperatures (SST) in a warming environment. While this study motivates the development of new methodologies in statistics and data mining, the ability to solve challenging climate science problems with innovative combinations of traditional and state-of-the-art methods is demonstrated. Here we develop new insights, albeit in a proof-of-concept sense, on the relationship between sea surface temperatures and hurricane frequencies, and generate the most likely projections with uncertainty bounds for storm counts in the 21st-century warming environment based in turn on the Intergovernmental Panel on Climate Change Special Report on Emissions Scenarios. Our preliminary insights point to the benefits that can be achieved for climate science and impacts analysis, as well as adaptation and mitigation policies, by a solution strategy that remains tailored to the climate domain and complements physics-based climate model simulations with a combination of existing and new computational and data science approaches.

  16. Low temperature cryoprobe

    DOE Patents [OSTI]

    Sungaila, Z.F.

    1988-04-12T23:59:59.000Z

    A portable, hand held probe usable within a small confine to produce a point source of nitrogen or helium at a relatively constant temperatures of 77 degrees Kelvin, is discussed. 3 figs.

  17. Effect of Soaking in Hot Saline Solution and Humid Atmosphere on the Passive Film Behavior of a Ni-Cr-Mo Alloy

    SciTech Connect (OSTI)

    P. Pharkya; J.H. Payer

    2006-06-09T23:59:59.000Z

    Alloy 22, a Ni-Cr-Mo alloy, is the candidate material for fabrication of canisters for disposal of high-level and spent nuclear fuel waste in the proposed Yucca Mountain repository in Nevada. This paper investigated the passive film behavior and corrosion properties on Alloy 22 as a function of soaking in hot, saline environments and in hot, humid atmospheres. Environmental parameters include potential, temperature, pH in chloride and multi-species solutions. Hot, humid exposures are planned for temperatures up to 300 C. Soaking times are planned to extend for up to 1000 hours. This work is part of a multi-investigator study to determine the durability of passive films and localized corrosion processes in metal exposed to moist particulate and deposits. Of particular interest are the long-term stability of the passive film and the effects of soaking in aqueous solutions or hot, humid atmospheres. A combination of electrochemical methods measure changes in passive film properties, and a combination of surface analysis techniques are used to characterize the film composition and structure. Electrochemical methods include Potentiodynamic Polarization tests for the general corrosion behavior; along with Electrochemical Impedance Spectroscopy (EIS) and Mott-Schottky (M-S) analysis for electronic properties of the passive films. Alterations in the chemical composition and structure of the passive film are characterized using X-ray Photoelectron Spectroscopy (XPS), Auger Electron Spectroscopy (AES) and Transmission Electron Microscopy (TEM). Results for freshly formed films are shown in figure 1. The EIS results show that the interfacial impedance increased with increasing potential to maximum within the passive range and then decreased as the potential was increased further. interfacial impedance was found to decrease with increasing temperature. Mott-Schottky analysis indicated that the oxide film which is n-type in the passive region changes to p-type in the transpassive region. Figure 2 shows the representative chemical soaking results at 90 C for up to 240 hours; the interfacial impedance increased with soaking time. Results from this work are combined with those from collaborative studies to correlate the passive film properties with the resistance to localized corrosion using multi-crevice assemblies and micro-corrosion cells. The passive film growth and dissolution are interpreted with reference to processes based on the point defect model.

  18. Influence of fine particles on the stability of a humid granular pile

    E-Print Network [OSTI]

    Xixi Huang; Sandrine Bec; J. Colombani

    2014-12-02T23:59:59.000Z

    We have investigated by rotating drum experiments the influence of a small amount of fine particles on the stability of a granular heap. The fine particles are shown to have a strong and ambivalent influence. For low fine particle content, the heap destabilizes by avalanches, and the fine particles tend to fluidize the heap. In contrast, for high fine particle content, they increase the cohesion of the heap, which destabilizes through stick-slip at the drum wall. We interpret and model the fluidification in the avalanching regime, which we show is independent of humidity, by granular lubrication considerations, whereas the stick-slip behavior, highly dependent on humidity, is understood by a solid friction model.

  19. Influence of fine particles on the stability of a humid granular pile

    E-Print Network [OSTI]

    Huang, Xixi; Colombani, J

    2014-01-01T23:59:59.000Z

    We have investigated by rotating drum experiments the influence of a small amount of fine particles on the stability of a granular heap. The fine particles are shown to have a strong and ambivalent influence. For low fine particle content, the heap destabilizes by avalanches, and the fine particles tend to fluidize the heap. In contrast, for high fine particle content, they increase the cohesion of the heap, which destabilizes through stick-slip at the drum wall. We interpret and model the fluidification in the avalanching regime, which we show is independent of humidity, by granular lubrication considerations, whereas the stick-slip behavior, highly dependent on humidity, is understood by a solid friction model.

  20. Underground reconnaissance and environmental monitoring related to geologic CO2 sequestration studies at the DUSEL Facility, Homestake Mine, South Dakota

    SciTech Connect (OSTI)

    Dobson, Patrick F.; Salve, Rohit

    2009-11-20T23:59:59.000Z

    Underground field reconnaissance was carried out in the Deep Underground Science and Engineering Laboratory (DUSEL) to identify potential locations for the planned geologic carbon sequestration experimental facility known as DUSEL CO{sub 2}. In addition, instrumentation for continuous environmental monitoring of temperature, pressure, and relative humidity was installed at various locations within the Homestake mine. The motivation for this work is the need to locate and design the DUSEL CO{sub 2} facility currently being planned to host CO{sub 2} and water flow and reaction experiments in long column pressure vessels over large vertical length scales. Review of existing geologic data and reconnaissance underground revealed numerous potential locations for vertical experimental flow columns, with limitations of existing vertical boreholes arising from limited vertical extent, poor continuity between drifts, and small diameter. Results from environmental monitoring over 46 days reveal spatial and temporal variations related to ventilation, weather, and ongoing dewatering of the mine.

  1. The effect of humidity on the collection efficiency for oxygenated compounds adsorbed on activated charcoal

    E-Print Network [OSTI]

    Walton, Robert Bruce

    1990-01-01T23:59:59.000Z

    and analyzed by gas chromatography. The National Institute for Occupational Safety and Health (NIOSH) has adopted this technique for more than one hundred individual chemicals. ~ One problem with using any adsorbent as a collection media is its ability...THE EPPECT OP HUMIDITY ON THE COLIECTION EFFICIENCY POR OXYGENATED COMPOUNDS ADSORBED ON ACTIVATED CHARCOAL A Thesis by ROBERT BRUCE WALTON Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment...

  2. Development and Analysis of a Sustainable Low Energy House in a Hot and Humid Climate

    E-Print Network [OSTI]

    Chulsukon, P.; Haberl, J. S.; Degelman, L. O.; Sylvester, K. E.

    2002-01-01T23:59:59.000Z

    cooling. In cold-climate countries, electricity is often used for space heating as well. Natural gas is mainly Energy Used in Building Demolition Demolition Removal Energy Used in Building Operation Space Cooling Lighting Equipment Water... Lifetime Building Energy Consumption Figure 1: Lifetime Building Energy Consumption Components for a Typical Residence in Thailand. used for only cooking for hot and humid climates such as Thailand. In cold climates, gas is also used for space...

  3. Role of Wind in Vernacular Architecture of Hot and Humid Region of Iran 

    E-Print Network [OSTI]

    Najafabadi, R. A.; Daneshvar, K.; Pakseresht, K.; Pooryousefzadeh, S.

    2006-01-01T23:59:59.000Z

    the structure, and whose projecting ends were usually left to serve as scaffolding for cleaning and maintenance (figure 7). Figure 7- Plan of wind tower shows an X configuration. Wind towers are often classified by the number of directions from...ROLE OF WIND IN VERNACULAR ARCHITECTURE OF HOT AND HUMID REGION OF IRAN RAHMAN AZARI NAJAFABADI ACADEMIC STAFF STUDENT KIMIYA DANESHVAR SAHAR PAKSERESHT SARA POORYOUSEFZADEH STUDENT STUDENT ART...

  4. Roots of Mold Problems and Humidity Control Measures in Institutional Buildings with Pre-Existing Mold Condition

    E-Print Network [OSTI]

    Chen, H.; Deng, S.; Bruner, H.; Garcia, J.

    2004-01-01T23:59:59.000Z

    Humidity control and mold in buildings has become an increasingly important problem. Once a building has experience mold growth on walls, ceilings, and other surfaces, it does not take longterm exposure to moisture for mold to re...

  5. The use of a distributed hydrologic model to predict dynamic landslide susceptibility for a humid basin in Puerto Rico

    E-Print Network [OSTI]

    Kamal, Sameer A. (Sameer Ahmed)

    2009-01-01T23:59:59.000Z

    This thesis describes the use of a distributed hydrology model in conjunction with a Factor of Safety (FS) algorithm to predict dynamic landslide susceptibility for a humid basin in Puerto Rico. The Mameyes basin, located ...

  6. Thermal Comfort Study in a Naturally Ventilated Residential Building in a Tropical Hot-Humid Climate Region

    E-Print Network [OSTI]

    Soebarto, V. I.; Handjarinto, S.

    1998-01-01T23:59:59.000Z

    This paper presents a thermal comfort study in a naturally ventilated residential building located in a tropical hot-humid climate region. The specific objective of this study is to investigate whether thermal comfort in this house can be achieved...

  7. Development of Temperature and Humidity-Based Indicators for Diagnosing Problems in Low Tonnage, Split System Air Conditioners 

    E-Print Network [OSTI]

    Watt, J. B.; O'Neal, D. L.; Haberl, J. S.

    1998-01-01T23:59:59.000Z

    and businesses. The unit had heat pump operation capability, however, the heat pump mode was not used in these tests. The entire assembly is shown in Figure 2. The evaporator section was connected to the condensing unit with copper tubing. The liquid... ): preprint. Lewis, J. 1987. Survey of residential air-to-air heat pump service life and maintenance issues. ASHRAE Transactions, 93( 1): 1 1 1 1 - 1 127. Lloyd, G.R., 1994. T.E.C.H. method lesson series. 27227 Weddel, Trenton, MI. McQuiston, F.C. and J...

  8. Warm Humid Climate: Methodology to Study Air Temperature Distribution: Mobile Phones Base Stations as Viable Alternative for Fixed Points

    E-Print Network [OSTI]

    Araujo, V.; Costa, A.; Labaki, L.

    2006-01-01T23:59:59.000Z

    always under that of human skin and with variable wind speed predominantly in southeast direction. The city is the capital of the state of Rio Grande do Norte, in the oriental coast of Brazil (Figure 01). Figure 01 – Natal localization in Brazil... Engineering, Architecture and Urban Planning – UNICAMP, Campinas, Brazil e-mail: angelina@fec.unicamp.br; e-mail: lucila@fec.unicamp.br (3) Federal University of Rio Grande do Norte - Department of Architecture and Urban Planning Caixa Postal 6021 Cep...

  9. Experimental Study in Energy Performance of Temperature and Humidity Independent Control System with Multiple Split Air-Conditioning System

    E-Print Network [OSTI]

    Kawano,M.

    2014-01-01T23:59:59.000Z

    to realizing Zero Energy Buildings (ZEB). 61% ?F ?F The amount of solar power Performance improvement of a building ? 30% reduction Efficiency of the air conditioning system ? 60? reduction 60% over reduction E le ct ri c P o w e r C o n su m p ti o n (K W h...-09-16 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 80 0.1 0.2 0.3 0.4 0.5 0.6 1? 4? 1? 11 ? 1? 16 ? 1? 17 ? 1? 18 ? 1? 21 ? 1? 22 ? 1? 30 ? 1? 31 ? 2? 1? 2? 4? 2? 5? 2? 6? 2? 7? 2? 8? 2? 12...

  10. Development of empirical temperature and humidity-based degraded-condition indicators for low-tonnage air conditioners

    E-Print Network [OSTI]

    Watt, James Bonner

    1997-01-01T23:59:59.000Z

    of conditions resulting in inefficient operation as reported by Neal from a survey of 10 residential air-conditioning units (Neal 1986, 1987). Problem Refri erant over-char e Refri erant under-char e Eva orator airflow inade uate Ev orator airflow too hi... wheel Freon char e Com onent Condition ratin Poor to Fair Poor to Fair Poor to Fair Return-air lenum Condensate s stem Su 1 air ducts Eva orator Coils Filter Controls Poor to Fair Poor to Avera e Fair to Avera e Fair to Good Fair to Good...

  11. Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

    SciTech Connect (OSTI)

    Kerrigan, P.; Norton, P.

    2014-10-01T23:59:59.000Z

    This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA.Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

  12. Development of a High-Performance Office Building Simulation Model for a Hot and Humid Climate

    E-Print Network [OSTI]

    Cho, S.; Haberl, J.

    -performance measures applicable to office buildings in hot and humid climates and to develop a high-performance (maximum energy-efficient) building model that only uses technologies readily available in the contemporary market. The high-performance model showed... requirements. This base-case model consumed a total of 7,721 GJ/yr. As shown in Figure 22, the implementation of occupancy sensors impacted the energy consumption the most, saving 11.2% of the total energy consumption. By this measure, indoor lights were...

  13. Energy Retrofit Field Study and Best Practices in a Hot-Humid Climate

    SciTech Connect (OSTI)

    McIvaine, J.; Sutherland, K.; Martin, E.

    2013-03-01T23:59:59.000Z

    Energy efficiency improvement as a component of comprehensive renovation was investigated under U.S. Department of Energy (DOE) funding of the Building America Partnership for Improved Residential Construction (BA-PIRC). Researchers at the Florida Solar Energy Center (FSEC) worked with affordable housing partners renovating foreclosed homes built from the 1950's through the 2000's in the hot-humid climate (within the Southern census region), primarily in Florida. Researchers targeted a 30% improvement in whole-house energy efficiency along with the health and safety, durability, and comfort guidelines outlined in DOE's Builders Challenge Program (Version 1) Quality Criteria.

  14. Guides and Case Studies for Hot-Humid Climates | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently Asked Questions for DOE FYAffairs, andCertificates, andandHot-Humid Climates Guides and

  15. Guides and Case Studies for Mixed-Humid Climates | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently Asked Questions for DOE FYAffairs, andCertificates, andandHot-Humid Climates

  16. Unusual oxidation states give reversible room temperature magnetocaloric effect on perovskite-related oxides SrFe{sub 0.5}Co{sub 0.5}O{sub 3}

    SciTech Connect (OSTI)

    Yin, C.; Liu, Q.; Decourt, R.; Pollet, M.; Gaudin, E. [CNRS, Universite de Bordeaux, ICMCB, 87 avenue du Dr. A. Schweitzer, Pessac F-33608 (France); Toulemonde, O., E-mail: toulemon@icmcb-bordeaux.cnrs.fr [CNRS, Universite de Bordeaux, ICMCB, 87 avenue du Dr. A. Schweitzer, Pessac F-33608 (France)

    2011-12-15T23:59:59.000Z

    The magnetic properties and the magnetocaloric effect are presented for the perovskite-related oxide SrFe{sub 0.5}Co{sub 0.5}O{sub 3} prepared using electrochemical oxidation. SrFe{sub 0.5}Co{sub 0.5}O{sub 3} exhibits a second order paramagnetic-ferromagnetic transition close to room temperature (T{sub C}=330 K). The maximal magnetic entropy change {Delta}S{sub M}{sup Max} , the maximal adiabatic temperature change {Delta}T{sub ad} and the refrigerant capacity are found to be equal to respectively 4.0 J/kgK, 1.8 K and 258 J/kg while raising the B-field change from 0 to 5 T. - Graphical Abstract: Moderate but reversible magnetocaloric properties are associated with the 2nd order paramagnetic to ferromagnetic phase transition exhibited at 330 K. A metal-like behavior is seen for the first time on the ferromagnetic regime. Highlights: Black-Right-Pointing-Pointer Both Fe{sup 4+} and Co{sup 4+} are stabilized on perovskite-related phase SrFe{sub 0.5}Co{sub 0.5}O{sub 3} using electrochemical oxidation. Black-Right-Pointing-Pointer Its crystallographic structure is cubic. Black-Right-Pointing-Pointer SrFe{sub 0.5}Co{sub 0.5}O{sub 3} is metal-like/ferromagnetic below 330 K Black-Right-Pointing-Pointer SrFe{sub 0.5}Co{sub 0.5}O{sub 3} exhibits magnetocaloric properties associated with the sharp paramagnetic to ferromagnetic phase transition.

  17. Temperature & Nuclear Fusion 4 October 2011

    E-Print Network [OSTI]

    Militzer, Burkhard

    Temperature & Nuclear Fusion 4 October 2011 Goals · Review temperature in stars · Practice using the important energy scales for nuclear fusion Temperature 1. For each relation we regularly use in class temperature. #12;temperature & nuclear fusion 2 Nuclear Fusion 2. There are a few different energy scales

  18. Optimal Indoor Air Temperature Considering Energy Savings and Thermal Comfort in the Shanghai Area

    E-Print Network [OSTI]

    Yao, Y.; Lian, Z.; Hou, Z.; Liu, W.

    2006-01-01T23:59:59.000Z

    influence on the optimal indoor air temperature than other influential factors. (2) The optimal indoor air temperature is nonlinear with the air velocity, and be linear with the air humidity and the clothes thermo-resistance. 25 25.5 26 26.5 27 27.5 28...) Optimal indoor air temperature in summer () ? Fig. 3 Influence of clothes thermo-resistance on the optimal indoor air temperature 3. OPTIMAL INDOOR AIR TEMPERATURE Known from the above analysis, when the indoor air velocity is below 0.3m...

  19. Temperature-sensitive optrode

    DOE Patents [OSTI]

    Hirschfeld, T.B.

    1985-09-24T23:59:59.000Z

    Method and apparatus are provided for measuring temperature and for generating optical signals related to temperature. Light from a fiber optic is directed to a material whose fluorescent response varies with ambient temperature. The same fiber optic delivering the excitation beam also collects a portion of the fluorescent emission for analysis. Signal collection efficiency of the fiber optic is enhanced by requiring that the fluorescent probe material be in the shape of an oblong parabolically tapered solid. Reproducibility is enhanced by using Raman backscatter to monitor excitation beam fluctuations, and by using measurements of fluorescence lifetime. 10 figs.

  20. Heating, Ventilation, and Air Conditioning Design Strategy for a Hot-Humid Production Builder

    SciTech Connect (OSTI)

    Kerrigan, P.

    2014-03-01T23:59:59.000Z

    BSC worked directly with the David Weekley Homes - Houston division to redesign three floor plans in order to locate the HVAC system in conditioned space. The purpose of this project is to develop a cost effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses. This is in preparation for the upcoming code changes in 2015. The builder wishes to develop an upgrade package that will allow for a seamless transition to the new code mandate. The following research questions were addressed by this research project: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost? BSC and the builder developed a duct design strategy that employs a system of dropped ceilings and attic coffers for moving the ductwork from the vented attic to conditioned space. The furnace has been moved to either a mechanical closet in the conditioned living space or a coffered space in the attic.

  1. HVAC Design Strategy for a Hot-Humid Production Builder, Houston, Texas (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-03-01T23:59:59.000Z

    BSC worked directly with the David Weekley Homes - Houston division to redesign three floor plans in order to locate the HVAC system in conditioned space. The purpose of this project is to develop a cost effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses. This is in preparation for the upcoming code changes in 2015. The builder wishes to develop an upgrade package that will allow for a seamless transition to the new code mandate. The following research questions were addressed by this research project: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost? BSC and the builder developed a duct design strategy that employs a system of dropped ceilings and attic coffers for moving the ductwork from the vented attic to conditioned space. The furnace has been moved to either a mechanical closet in the conditioned living space or a coffered space in the attic.

  2. Approaches to 30% Energy Savings at the Community Scale in the Hot-Humid Climate

    SciTech Connect (OSTI)

    Thomas-Rees, S.; Beal, D.; Martin, E.; Fonorow, K.

    2013-03-01T23:59:59.000Z

    BA-PIRC has worked with several community-scale builders within the hot humid climate zone to improve performance of production, or community scale, housing. Tommy Williams Homes (Gainesville, FL), Lifestyle Homes (Melbourne, FL), and Habitat for Humanity (various locations, FL) have all been continuous partners of the BA Program and are the subjects of this report to document achievement of the Building America goal of 30% whole house energy savings packages adopted at the community scale. The scope of this report is to demonstrate achievement of these goals though the documentation of production-scale homes built cost-effectively at the community scale, and modeled to reduce whole-house energy use by 30% in the Hot Humid climate region. Key aspects of this research include determining how to evolve existing energy efficiency packages to produce replicable target savings, identifying what builders' technical assistance needs are for implementation and working with them to create sustainable quality assurance mechanisms, and documenting the commercial viability through neutral cost analysis and market acceptance. This report documents certain barriers builders overcame and the approaches they implemented in order to accomplish Building America (BA) Program goals that have not already been documented in previous reports.

  3. Creeping bentgrass performance, water relations, and soil gas response to three irrigation frequencies in a hot-humid climate

    E-Print Network [OSTI]

    Jordan, John Ellis

    1998-01-01T23:59:59.000Z

    , and root mass than did the 1-day and 2-day treatments in August of 1997 and 1998. There was no difference in turf quality among irrigation frequencies in 1998, however, due to increased algae formation in 1997, the 4-day treatment mainlined greater turf...

  4. Absorption and translocation of 2,4-D in beans as influenced by relative humidity and soil moisture

    E-Print Network [OSTI]

    Leinweber, Charles Lee

    1953-01-01T23:59:59.000Z

    neoesaax'y for al30orpliion and trinsloca- tion of dorbio10es ln mesquite. Plant's in small irx lp:ted , -, lots within lar~~'e areas oprayed w1th hoxbicides showed no dis- adv' nlj" g~'e ovsx' un'L Ltered plants in basF 1 ortcp Lci]. 1 Con versely, a...

  5. Sequential high temperature reduction, low temperature hydrolysis...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    high temperature reduction, low temperature hydrolysis for the regeneration of sulfated NOx trap catalysts. Sequential high temperature reduction, low temperature hydrolysis for...

  6. Tribological performance of diamond and diamondlike carbon films at elevated temperatures

    SciTech Connect (OSTI)

    Erdemir, A.; Fenske, G.R.

    1995-09-01T23:59:59.000Z

    In this study, we investigated the tribological performance of diamond and diamondlike carbon (DLC) films as a function of ambient temperature. Both films were deposited on silicon carbide (SiC) by microwave plasma chemical vapor deposition and ion-beam deposition processes. Tribological tests were performed on a reciprocating wear machine in open air (20 to 30% relative humidity) and under a 10-N load using SiC pins. For the test conditions explored, the steady- state friction coefficients of test pairs without a diamond or DLC film were 0.7 to 0.9 and the average wear rates of pins were 10{sup {minus}5} to 10{sup {minus}7} mm{sup 3}/N.m, depending on ambient temperature. DLC films reduced the steady-state friction coefficients of test pairs by factors of 3 to 5 and the wear rates of pins by two to three orders of magnitude. Low friction coefficients were also obtained with the diamond films, but wear rates of the counterface pins were high due to the very abrasive nature of these films. The wear of SiC disks coated with either diamond or DLC films was virtually unmeasurable while the wear of uncoated disks was substantial. Test results showed that the DLC films could afford low friction up to about 300{degrees}C. At higher temperatures, the DLC films became graphitized and were removed from the surface. The diamond films could withstand much higher temperatures, but their tribological behavior degraded. Raman spectroscopy and scanning electron microscopy were used to elucidate the friction and wear mechanisms of both films at high temperatures.

  7. Are tropical forests near a high temperature threshold?

    E-Print Network [OSTI]

    Doughty, Christopher E.; Goulden, Michael L.

    2008-01-01T23:59:59.000Z

    occurs at a relatively modest temper- ature (many temperatestrongly sensitive to modest increases in bulk temperature.

  8. variability temperature

    E-Print Network [OSTI]

    balance benguela biases buoyancy cod comparisons convection cooling energy error estimation fluctuations related relative remote resolution results sampling ships studies validation weather world approach pacificocean phase plankton predictability present principal shelf shift simulated southwest statistics

  9. Investigations on Vapour Compression Air Conditioner with Direct Contact Desiccant Loop over Condenser and Evaporator

    E-Print Network [OSTI]

    Maiya, M. P.; Ravi, J.; Tiwari, S.

    2010-01-01T23:59:59.000Z

    Perceived air quality increases when relative humidity is decreased till about 30% in the range of comfort temperature. In the present scenario, humidity is considered as a pollutant. Hence, a controlled environment not only at low temperature...

  10. Efficient Multifamily Homes in a Hot-Humid Climate by Atlantic Housing Partners

    SciTech Connect (OSTI)

    Chasar, D.; Martin, E.

    2013-04-01T23:59:59.000Z

    With assistance from the Florida Solar Energy Center (FSEC) and its Building America Partnership for Improved Residential Construction (BA-PIRC), Atlantic Housing Partners (AHP) has implemented a high performance, systems engineered package of measures. This report demonstrates how the initiative achieves Building America (BA) goals of 30%-50% energy savings. Specifically, the goals are documented as being achieved in the new construction multifamily housing sector in the hot humid climate. Results from energy modeling of the high performance package are presented. The role of utility allowance calculations, used as part of the low-income housing tax credit process, to value those energy savings is discussed, as is customer satisfaction with heat pump water heaters.

  11. PARAMETRIC STUDY OF GROUND SOURCE HEAT PUMP SYSTEM FOR HOT AND HUMID CLMATE

    SciTech Connect (OSTI)

    Jiang Zhu; Yong X. Tao

    2011-11-01T23:59:59.000Z

    The U-tube sizes and varied thermal conductivity with different grout materials are studied based on the benchmark residential building in Hot-humid Pensacola, Florida. In this study, the benchmark building is metered and the data is used to validate the simulation model. And a list of comparative simulation cases with varied parameter value are simulated to study the importance of pipe size and grout to the ground source heat pump energy consumption. The simulation software TRNSYS [1] is employed to fulfill this task. The results show the preliminary energy saving based on varied parameters. Future work needs to be conducted for the cost analysis, include the installation cost from contractor and materials cost.

  12. Impact of Residential Mechanical Ventilation on Energy Cost and Humidity Control

    SciTech Connect (OSTI)

    Martin, E.

    2014-01-01T23:59:59.000Z

    The DOE Building America program has been conducting research leading to cost effective high performance homes since the early 1990's. Optimizing whole house mechanical ventilation as part of the program's systems engineered approach to constructing housing has been an important subject of the program's research. Ventilation in residential buildings is one component of an effective, comprehensive strategy for creation and maintenance of a comfortable and healthy indoor air environment. The study described in this white paper is based on building energy modeling with an important focus on the indoor humidity impacts of ventilation. The modeling tools used were EnergyPlus version 7.1 (E+) and EnergyGauge USA (EGUSA). Twelve U.S. cities and five climate zones were represented. A total of 864 simulations (2*2*3*3*12= 864) were run using two building archetypes, two building leakage rates, two building orientations, three ventilation systems, three ventilation rates, and twelve climates.

  13. Reducing Thermal Losses and Gains With Buried and Encapsulated Ducts in Hot-Humid Climates

    SciTech Connect (OSTI)

    Shapiro, C.; Magee, A.; Zoeller, W.

    2013-02-01T23:59:59.000Z

    The Consortium for Advanced Residential Buildings (CARB) monitored three houses in Jacksonville, FL, to investigate the effectiveness of encapsulated and encapsulated/buried ducts in reducing thermal losses and gains from ductwork in unconditioned attics. Burying ductwork beneath loose-fill insulation has been identified as an effective method of reducing thermal losses and gains from ductwork in dry climates, but it is not applicable in humid climates where condensation may occur on the outside of the duct jacket. By encapsulating the ductwork in closed cell polyurethane foam (ccSPF) before burial beneath loose-fill mineral fiber insulation, the condensation potential may be reduced while increasing the R-value of the ductwork.

  14. Exploring Cost-Effective, High Performance Residential Retrofits for Affordable Housing in the Hot Humid Climate

    SciTech Connect (OSTI)

    McIlvaine, Janet; Sutherland, Karen; Schleith, Kevin; Chandra, Subrato

    2010-08-27T23:59:59.000Z

    In 2009, a Department of Energy Building America team led by the Florida Solar Energy Center began working with partners to find cost-effective paths for improving the energy performance of existing homes in the hot humid climate. A test-in energy audit and energy use modeling of the partner's proposed renovation package was performed for 41 affordable and middle income foreclosed homes in Florida and Alabama. HERS1 Indices ranged from 92 to 184 with modeled energy savings ranging from 3% to 50% (average of 26%). Analyses and recommendations were discussed with partners to encourage more efficient retrofits, highlight health and safety issues, and gather feedback on incremental cost of high performance measures. Ten completed renovations have modeled energy savings ranging from 9% to 48% (average 31%.) This paper presents the project's process including our findings thus far and highlights of the first home to meet the target HERS Index of 70.

  15. Kinetics of the reaction of iron blast furnace slag/hydrated lime sorbents with SO{sub 2} at low temperatures: effects of the presence of CO{sub 2}, O{sub 2}, and NOx

    SciTech Connect (OSTI)

    Liu, C.F.; Shih, S.M. [Industrial Technological Research Institute, Hsinchu (Taiwan)

    2009-09-15T23:59:59.000Z

    The effects of the presence of CO{sub 2}, O{sub 2}, and NOx in the flue gas on the kinetics of the sulfation of blast furnace slag/hydrated lime sorbents at low temperatures were studied using a differential fixed-bed reactor. When O{sub 2} and NOx were not present simultaneously, the reaction kinetics was about the same as that under the gas mixtures containing SO{sub 2}, H{sub 2}O, and N{sub 2} only, being affected mainly by the relative humidity. The sulfation of sorbents can be described by the surface coverage model and the model equations derived for the latter case. When both O{sub 2} and NOx, were present, the sulfation of sorbents was greatly enhanced, forming a great amount of sulfate in addition to sulfite. The surface coverage model is still valid in this case, but the model equations obtained show a more marked effect of relative humidity and negligible effects of SO{sub 2} concentration and temperature on the reaction. The effect of sorbent composition on the reaction kinetics was entirely represented by the effects of the initial specific surface area (S{sub g0}) and the Ca molar content (M{sup -1}) of sorbent. The initial conversion rate of sorbent increased linearly with increasing S{sub g0}, and the ultimate conversion increased linearly with increasing S{sub g0}M{sup -1}. The model equations obtained in this work are applicable to describe the kinetics of the sulfation of the sorbents in the low-temperature dry and semidry fine gas desulfurization processes either with an upstream NOx, removal unit or without.111

  16. Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates: Application of High Performance Measures and Renewable Energy Systems 

    E-Print Network [OSTI]

    Im, P.; Haberl, J.

    2010-01-01T23:59:59.000Z

    This paper presents the analysis of the energy savings potential in an existing K-5 school in hot and humid climates. Previous paper (Im and Haberl 2008b) presented a calibrated simulation procedure for an existing K-5 school in hot and humid area...

  17. Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control: Report and Summary Report

    SciTech Connect (OSTI)

    Dean, J.; Kozubal, E.; Herrmann, L.; Miller, J.; Lowenstein, A.; Barker, G.; Slayzak, S.

    2012-11-01T23:59:59.000Z

    The primary objective of this project was to demonstrate the capabilities of a new high-performance, liquid-desiccant dedicated outdoor air system (DOAS) to enhance cooling efficiency and comfort in humid climates while substantially reducing electric peak demand at Tyndall Air Force Base (AFB), which is 12 miles east of Panama City, Florida.

  18. Wall Design Redundancy for Improving the Moisture Performance of Building Cladding Systems in Hot-Humid Climates

    E-Print Network [OSTI]

    Graham, C. W.

    2000-01-01T23:59:59.000Z

    An investigation of approximately 4,000 buildings in the hot-humid climate locations of the United States where the potential for decay of hygroscopic building materials or corrosion of metals is moderate-to-severe found that redundant moisture...

  19. Morphological characteristics in relation to seed deterioration in sorghum

    E-Print Network [OSTI]

    Ellis, Eugene Bailey

    1972-01-01T23:59:59.000Z

    background, maturity, and disease on seed deterioration was investigated in relation to the above morpholog- ical characteristics. Standard germination tests were conducted on seed harvested at three stages of maturity and on seed from the first... and second har- vests that had been artificially aged for five days at 45 C and 100/ relative humidity. A cold soil emergence test also was con- ducted on the seed from the first and second harvests. The percent of seed infected with fungi was determined...

  20. Temperature & Nuclear Fusion 4 October 2011

    E-Print Network [OSTI]

    Militzer, Burkhard

    Temperature & Nuclear Fusion 4 October 2011 Goals · Review temperature in stars · Practice using the important energy scales for nuclear fusion Temperature 1. For each relation we regularly use in class-Boltzmann equation: L = 4R2 T4 . (d) In fusion energy generation: T . #12;temperature & nuclear fusion 2 Nuclear

  1. High temperature adsorption measurements

    SciTech Connect (OSTI)

    Bertani, R.; Parisi, L.; Perini, R.; Tarquini, B.

    1996-01-24T23:59:59.000Z

    Adsorption phenomena are a rich and rather new field of study in geothermal research, in particular at very high temperature. ENEL is interested in the exploitation of geothermal regions with superheated steam, and it is important to understand the behavior of water-rock interaction. We have analyzed in the 170-200 °C temperature range four samples of Monteverdi cuttings; the next experimental effort will be at 220 °C and over in 1996. The first results of the 1995 runs are collected in this paper. We can highlight four main items: 1. At relative pressures over 0.6 the capillarity forces are very important. 2. There is no significant temperature effect. 3. Adsorbed water can be present, and it is able to multiply by a factor of 15 the estimated reserve of super-heated steam only. 4. Pores smaller than 15 Å do not contribute to the adsorbed mass.

  2. air temperature air: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    air temperatures... conditions. The design of this study was based on the relation- ship of four parameters: air temperature, air velocity, radiant heat, and globe...

  3. Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot-Humid Climate

    SciTech Connect (OSTI)

    Sutherland, K.; Martin, E.

    2013-02-01T23:59:59.000Z

    This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

  4. Condensation potential in high thermal performance walls. Hot, humid summer climate. Forest Service research paper

    SciTech Connect (OSTI)

    Sherwood, G.E.

    1985-07-01T23:59:59.000Z

    To observe actual moisture patterns and the potential for condensation due to long periods of air conditioning in a hot, humid climate, a test structure was constructed near Gulfport, Mississippi, for exposure of eight types of insulated wall panels at controlled indoor conditions and typical outdoor weather conditions. Panels were instrumented with moisture sensors and tested without (Phase 1) and with (Phase 2) penetrations (electrical outlets) in the indoor surface. There was no sustained condensation in any of the walls during either winter season. One type of high thermal performance wall had sustained condensation during both summers, but the wall dried out as the weather became cooler, and moisture content of framing never exceeded 17 percent. Low-permeance sheathing appeared to provide resistance to the buildup of moisture during summer in walls with high overall R values. Penetrating the walls with electrical outlets resulted in slightly higher moisture levels in all of the walls throughout the year. This paper should be useful to building designers, builders, and building code officials in establishing vapor retarder requirements for walls.

  5. Public Health-Related Impacts of Climate Change inCalifornia

    SciTech Connect (OSTI)

    Drechsler, D.M.; Motallebi, N.; Kleeman, M.; Cayan, D.; Hayhoe,K.; Kalkstein, L.S.; Miller, N.L.; Jin, J.; VanCuren, R.A.

    2005-12-01T23:59:59.000Z

    In June 2005 Governor Arnold Schwarzenegger issued Executive Order S-3-05 that set greenhouse gas emission reduction targets for California, and directed the Secretary of the California Environmental Protection Agency to report to the governor and the State legislature by January 2006 and biannually thereafter on the impacts to California of global warming, including impacts to water supply, public health, agriculture, the coastline, and forestry, and to prepare and report on mitigation and adaptation plans to combat these impacts. This report is a part of the report to the governor and legislature, and focuses on public health impacts that have been associated with climate change. Considerable evidence suggests that average ambient temperature is increasing worldwide, that temperatures will continue to increase into the future, and that global warming will result in changes to many aspects of climate, including temperature, humidity, and precipitation (McMichael and Githeko, 2001). It is expected that California will experience changes in both temperature and precipitation under current trends. Many of the changes in climate projected for California could have ramifications for public health (McMichael and Githeko, 2001), and this document summarizes the impacts judged most likely to occur in California, based on a review of available peer-reviewed scientific literature and new modeling and statistical analyses. The impacts identified as most significant to public health in California include mortality and morbidity related to temperature, air pollution, vector and water-borne diseases, and wildfires. There is considerable complexity underlying the health of a population with many contributing factors including biological, ecological, social, political, and geographical. In addition, the relationship between climate change and changes in public health is difficult to predict for the most part, although more detailed information is available on temperature-related mortality and air pollution effects than the other endpoints discussed in this document. Consequently, these two topics are discussed in greater detail. Where possible, estimates of the magnitude and significance of these impacts are also discussed, along with possible adaptations that could reduce climate-related health impacts. In the context of this review, weather refers to meteorological conditions at a specific place and time over a relatively short time frame, such as up to a year or two. Climate, on the other hand, refers to the same meteorological conditions, but over a longer time frame, such as decades or centuries.

  6. Light and electron microscopic studies of the nanobenthic diatom, Nitzschia ovalis Arnott, Section Lanceolatae, as compared to related forms, and the effect of temperature and salinity on its growth rate

    E-Print Network [OSTI]

    Medlin, Linda Karen

    1977-01-01T23:59:59.000Z

    Selection and Maintenance of Diatoms to be Studied . 13 Preparation of Glassware and Culture Media. Preparation and Examination of Cells. Determination of Temperature and Salinity Tolerances and Optima for the growth of Nitzschia ovalis Arnott RESULTS... Light Microscopy. Electron Microscopy Salinity and Temperature Tolerances and Optima. DISCUSSION. Morphological Studies Physiological Studies SUMMARy LITERATURE. APPENDIX A. VITA. 15 18 20 24 24 46 110 124 124 131 139 141 149 BIST...

  7. "Orobiomes" Mountain Biomes "Orobiomes" in relation to sea level biomes. Very roughly, the sea level biomes become

    E-Print Network [OSTI]

    Richerson, Peter J.

    terracing. The scattered white spots are the metal roofs of farm families' houses. Notice the cloud hanging just above the farms. #12;Cloud Forest. Because the temperature changes little throughout the year and humidity is generally high, the bottom of the cloud deck stays at about the same elevation all the time

  8. Plants for passive cooling. A preliminary investigation of the use of plants for passive cooling in temperate humid climates

    SciTech Connect (OSTI)

    Spirn, A W; Santos, A N; Johnson, D A; Harder, L B; Rios, M W

    1981-04-01T23:59:59.000Z

    The potential of vegetation for cooling small, detached residential and commercial structures in temperate, humid climates is discussed. The results of the research are documented, a critical review of the literature is given, and a brief review of energy transfer processes is presented. A checklist of design objectives for passive cooling, a demonstration of design applications, and a palette of selected plant species suitable for passive cooling are included.

  9. The Successful Design Construction and 'Live-ability' of an Energy Efficient Home in a Hot and Humid Climate

    E-Print Network [OSTI]

    Gardner, J. C.

    2006-01-01T23:59:59.000Z

    clothes washer null Energy Star Hunter ceiling fans null 90% of the lighting is fluorescent null Gas fired water heater with solar assist For those ten really cold days in winter we have a wood burning stove with catalytic converter to supplement...The Successful Design, Construction and “Live-ability” of an Energy Efficient Home in a Hot and Humid Climate John C. Gardner, PE Hockley, Texas 77447 ABSTRACT This paper will present a case study of an energy efficient home...

  10. Natural Ventilation Applications in Hot-humid Climate: A Preliminary Design for the College of Design at NTUST 

    E-Print Network [OSTI]

    Lin, M. T.; Wei, H. Y.; Lin, Y. J.; Wu, H. F.; Liu, P. H.

    2010-01-01T23:59:59.000Z

    to create a comfortable architectural environment, especially in a hot, humid climate such as that of Taiwan. However, the air currents of urban wind fields are unpredictable and whimsical. The conventional architectural design process does not employ... the effectiveness of using natural ventilation for comfort, several factors have a strong impact on ventilation design schemes, namely objective analysis of the climatic profile, urban blocks and wind effects, and ventilation routes. These factors not only...

  11. Field-Evaluation of Alternative HVAC Strategies to Meet Ventilation, Comfort and Humidity Control Criteria at Three Full-Serve Restaurants

    E-Print Network [OSTI]

    Yborra, S. C.; Spears, J. W.

    2000-01-01T23:59:59.000Z

    Lighting and ventilation represent the majority of the air conditioning loads in office buildings in hot humid climates. Use of motion sensors is one way to minimize the energy used for these loads. This paper describes the methods used...

  12. Field-Evaluation of Alternative HVAC Strategies to Meet Ventilation, Comfort and Humidity Control Criteria at Three Full-Serve Restaurants 

    E-Print Network [OSTI]

    Yborra, S. C.; Spears, J. W.

    2000-01-01T23:59:59.000Z

    Lighting and ventilation represent the majority of the air conditioning loads in office buildings in hot humid climates. Use of motion sensors is one way to minimize the energy used for these loads. This paper describes the methods used...

  13. Evapotranspiration of Cool-Season Turfgrasses in the Humid Northeast' L. J. Aronson, A. J. Gold, R. J. Hull, and J. L. Cisar2

    E-Print Network [OSTI]

    Gold, Art

    Evapotranspiration of Cool-Season Turfgrasses in the Humid Northeast' L. J. Aronson, A. J. Gold, R loam(coarse-siltyoversandy-skeletal, mixed, mesic Typic Dystrocrept),and ET was determinedby weigh- ing

  14. Building America Case Study: Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-11-01T23:59:59.000Z

    This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA. Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

  15. Energy Master Plans for Sustainable, High Performance HVAC and Associated Systems for Hot and Humid Climates

    E-Print Network [OSTI]

    Maisey, G. E.; Milestone, B.

    2004-01-01T23:59:59.000Z

    of the upper management objectives and strategies. If upper management considers comfort and productivity an issue, then it will be improved. If upper management considers energy efficiency and overall maintenance effectiveness an issue, it will improve... than the ambient temperature for thermal comfort. A radiant temperature system using water in pipes, serpentined in the ceiling and floor, walls, etc., not only will provide better comfort, but it can move energy around ten times more efficiently...

  16. High Temperatures & Electricity Demand

    E-Print Network [OSTI]

    High Temperatures & Electricity Demand An Assessment of Supply Adequacy in California Trends.......................................................................................................1 HIGH TEMPERATURES AND ELECTRICITY DEMAND.....................................................................................................................7 SECTION I: HIGH TEMPERATURES AND ELECTRICITY DEMAND ..........................9 BACKGROUND

  17. S. Wasterlain, D. Candusso, D. Hissel, F. Harel, P. Bergman, P. Menard, M. Anwar (fvrier 2010). Study of temperature, air dew point temperature and reactant flow effects on PEMFC

    E-Print Network [OSTI]

    Boyer, Edmond

    (relative humidity of 12%). The FC characterizations tests have been conducted using in-situ electrochemical measurements, cyclic and linear sweep voltammetries (CV and LSV). The impacts of the parameters on the global. Keywords: PEMFC; Characterization; Electrochemical Impedance Spectroscopy; Cyclic Voltammetry; Linear Sweep

  18. Metal-air low temperature ionic liquid cell

    DOE Patents [OSTI]

    Friesen, Cody A; Buttry, Daniel A

    2014-11-25T23:59:59.000Z

    The present application relates to an electrochemical metal-air cell in which a low temperature ionic liquid is used.

  19. Method for measuring surface temperature

    DOE Patents [OSTI]

    Baker, Gary A. (Los Alamos, NM); Baker, Sheila N. (Los Alamos, NM); McCleskey, T. Mark (Los Alamos, NM)

    2009-07-28T23:59:59.000Z

    The present invention relates to a method for measuring a surface temperature using is a fluorescent temperature sensor or optical thermometer. The sensor includes a solution of 1,3-bis(1-pyrenyl)propane within a 1-butyl-1-1-methyl pyrrolidinium bis(trifluoromethylsulfonyl)imide ionic liquid solvent. The 1,3-bis(1-pyrenyl)propane remains unassociated when in the ground state while in solution. When subjected to UV light, an excited state is produced that exists in equilibrium with an excimer. The position of the equilibrium between the two excited states is temperature dependent.

  20. Drexel University Temperature Sensors

    SciTech Connect (OSTI)

    K. L. Davis; D. L. Knudson; J. L. Rempe; B. M. Chase

    2014-09-01T23:59:59.000Z

    This document summarizes background information and presents results related to temperature measurements in the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) Drexel University Project 31091 irradiation. The objective of this test was to assess the radiation performance of new ceramic materials for advanced reactor applications. Accordingly, irradiations of transition metal carbides and nitrides were performed using the Hydraulic Shuttle Irradiation System (HSIS) in the B-7 position and in static capsules inserted into the A-3 and East Flux Trap Position 5 locations of the ATR.

  1. ARM - Word Seek: Temperature

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625govInstrumentstdmadapInactiveVisiting the TWP TWP Related Links Facilities and InstrumentsInstrumentsTemperature

  2. Optical Properties of Moderately-Absorbing Organic and Mixed Organic/Inorganic Particles at Very High Humidities

    SciTech Connect (OSTI)

    Bond, Tami C; Rood, Mark J; Brem, Benjamin T; Mena-Gonzalez, Francisco C; Chen, Yanju

    2012-04-16T23:59:59.000Z

    Relative humidity (RH) affects the water content of an aerosol, altering its ability to scatter and absorb light, which is important for aerosol effects on climate and visibility. This project involves in situ measurement and modeling of aerosol optical properties including absorption, scattering and extinction at three visible wavelengths (467, 530, 660 nm), for organic carbon (OC) generated by pyrolysis of biomass, ammonium sulfate and sodium chloride, and their mixtures at controlled RH conditions. Novel components of this project include investigation of: (1) Changes in all three of these optical properties at scanned RH conditions; (2) Optical properties at RH values up to 95%, which are usually extrapolated instead of measured; and (3) Examination of aerosols generated by the pyrolysis of wood, which is representative of primary atmospheric organic carbon, and its mixture with inorganic aerosol. Scattering and extinction values were used to determine light absorption by difference and single scattering albedo values. Extensive instrumentation development and benchmarking with independently measured and modeled values were used to obtain and evaluate these new results. The single scattering albedo value for a dry absorbing polystyrene microsphere benchmark agreed within 0.02 (absolute value) with independently published results at 530 nm. Light absorption by a nigrosin (sample light-absorbing) benchmark increased by a factor of 1.24 +/-0.06 at all wavelengths as RH increased from 38 to 95%. Closure modeling with Mie theory was able to reproduce this increase with the linear volume average (LVA) refractive index mixing rule for this water soluble compound. Absorption by biomass OC aerosol increased by a factor of 2.1 +/- 0.7 and 2.3 +/- 1.2 between 32 and 95% RH at 467 nm and 530 nm, but there was no detectable absorption at 660 nm. Additionally, the spectral dependence of absorption by OC that was observed with filter measurements was confirmed qualitatively in situ at 467 and 530 nm. Closure modeling with the dynamic effective medium approximation (DEMA) refractive index model was able to capture the increasing absorption trend with RH indicating that the droplets were heterogeneously mixed while containing dispersed insoluble absorbing material within those droplets. Seven other refractive index mixing models including LVA did not adequately describe the measurements for OC. Mixing the biomass OC aerosol with select mass fractions of ammonium sulfate ranging from 25 to 36% and sodium chloride ranging from 21 to 30% resulted in an increase in light scattering and extinction with RH and inorganic mass fraction. However, no detectable difference in light absorption behavior in comparison to pure biomass OC was observed. The main finding of this research is a measured increase in absorption with increasing RH, which is currently not represented in radiative transfer models even though biomass burning produces most of the primary OC aerosol in the atmosphere.

  3. Innovative HVAC Cycles for Severe Part Load Conditions in the Humid Climate

    E-Print Network [OSTI]

    Pate, M. E.; Todd, T. R.

    1987-01-01T23:59:59.000Z

    to very cold supply air temperatures at part loads. Face & bypass avoids this short- coming and meets both performance criteria quite well. Figures 1 and 2 compare the performance of a chilled water valve vs. face & bypass control under various load8...

  4. Building a 40% Energy Saving House in the Mixed-Humid Climate

    SciTech Connect (OSTI)

    Christian, Jeffrey E [ORNL; Bonar, Jacob [ORNL

    2011-10-01T23:59:59.000Z

    This report describes a home that uses 40% less energy than the energy-efficient Building America standard - a giant step in the pursuit of affordable near-zero-energy housing through the evolution of five near-zero-energy research houses. This four-bedroom, two-bath, 1232-ft2 house has a Home Energy Rating System (HERS) index of 35 (a HERS rating of 0 is a zero-energy house, a conventional new house would have a HERS rating of 100), which qualifies it for federal energy efficiency and solar incentives. The house is leading to the planned construction of a similar home in Greensburg, Kansas, and 21 staff houses in the Walden Reserve, a 7000-unit "deep green" community in Cookville, Tennessee. Discussions are underway for construction of similar houses in Charleston, South Carolina, Seattle, Washington, Knoxville and Oak Ridge, Tennessee, and upstate New York. This house should lead to a 40% and 50% Gate-3, Mixed-Humid-Climate Joule for the DOE Building America Program. The house is constructed with structurally-insulated-panel walls and roof, raised metal-seam roof with infrared reflective coating, airtight envelope (1.65 air changes per hour at 50 Pascal), supply mechanical ventilation, ducts inside the conditioned space, extensive moisture control package, foundation geothermal space heating and cooling system, ZEHcor wall, solar water heater, and a 2.2 kWp grid-connected photovoltaic (PV) system. The detailed specifications for the envelope and the equipment used in ZEH5 compared to all the houses in this series are shown in Tables 1 and 2. Based on a validated computer simulation of ZEH5 with typical occupancy patterns and energy services for four occupants, energy for this all-electric house is predicted to cost only $0.66/day ($0.86/day counting the hookup charges). By contrast, the benchmark house would require $3.56/day, including hookup charges (these costs are based on a 2006 residential rates of $0.07/kWh and solar buyback at $0.15/kWh). The solar fraction for this home located in Lenoir City, Tennessee, is predicted to be as high as 41%(accounting for both solar PV and the solar water heater). This all-electric home is predicted to use 25 kWh/day based on the one year of measured data used to calibrate a whole-building simulation model. Based on two years of measured data, the roof-mounted 2.2 kWp PV system is predicted to generate 7.5 kWh/day. The 2005 cost to commercially construct ZEH5, including builder profit and overhead, is estimated at about $150,000. This cost - for ZEH5's panelized construction, premanufactured utility wall (ZEHcor), foundation geothermal system, and the addition of the walkout lower level, and considering the falling cost for PV - suggests that the construction cost per ft2 for a ZEH5 two-story will be even more cost-competitive. The 2005 construction cost estimate for a finished-out ZEH5 with 2632 ft2 is $222,000 or $85/ft2. The intention of this report is to help builders and homeowners make the decision to build zero-energy-ready homes. Detailed drawings, specifications, and lessons learned in the construction and analysis of data from about 100 sensors monitoring thermal performance for a one-year period are presented. This information should be specifically useful to those considering structural insulated panel walls and roof, foundation geothermal space heating and cooling, solar water heater and roof-mounted, photovoltaic, grid-tied systems.

  5. Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates 

    E-Print Network [OSTI]

    O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

    1996-01-01T23:59:59.000Z

    provided rebates to residential customers for purchasing high efficiency air conditioners and heat pumps. The rebates have helped increase the demand for higher efficiency air conditioning units. However, even the most efficient system will not perform... quanm the effect of air leakage in the return air duct from a hot attic space on the high-temperature performance of air conditioners and heat pump systems. Air conditioner performance is quantified in terms of capacity, Energy Efficiency Ratio (EER...

  6. Low-temperature magnetic refrigerator

    DOE Patents [OSTI]

    Barclay, J.A.

    1983-05-26T23:59:59.000Z

    The invention relates to magnetic refrigeration and more particularly to low temperature refrigeration between about 4 and about 20 K, with an apparatus and method utilizing a belt of magnetic material passed in and out of a magnetic field with heat exchangers within and outside the field operably disposed to accomplish refrigeration.

  7. Weather data handbook for HVAC and cooling equipment design

    SciTech Connect (OSTI)

    Not Available

    1980-01-01T23:59:59.000Z

    Data included detailed tabulations of wet bulb temperature frequencies for the summer months, tabulations in multiple frequency for winter and summer conditions, various weather parameters useful in estimating performance for heat exchange equipment and other applications. Other data provided are: 12-month dry bulb temperatures and 12-month wet bulb temperatures vs relative humidity; combination of wet bulb temperatures, wind speed, and relative humidity; wind direction with high relative humidities; hourly observations for relative humidity 93% or greater; coincident high wet bulb and dry bulb temperature, seasonal cloud cover, and heat islands. (MHR)

  8. The effect of temperature and time on the mechanical properties of lightly milled rice

    E-Print Network [OSTI]

    Maa, Tsorng-Jong

    1974-01-01T23:59:59.000Z

    MATERIALS AND EQUIPMENT Test Apparatus Dynamic Relative Humidity System PROCEDURE Milling and Equilibrating the R1ce Grain Compression Experiments Tension Experiments 10 10 12 14 15 16 Determination of Strength during Noisture Adsorption... TENSION LOADING OF BLUEBELLE LIGHTLY MILLED RICE 2 RESULTS FROM COMPRESSION LOADING OF BLUEBELLE LIGHTLY MILLED RICE 3 RESULTS FROM LOADING OF BLUEBELLE LIGHTLY MILLED RICE IN DIFFERENT POSITIONS 27 28 47 LIST OF FIGURES Figure Page Arrangement...

  9. Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates

    E-Print Network [OSTI]

    O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

    1996-01-01T23:59:59.000Z

    were designed for testing systems with cooling capacities of up to 10 tons. The unit used for return air leakage tests was a 3.5 ton (12.3 kW) split system air conditioner with TXV expansion and a scroll compressor. It had a seasonal energy... leakage on capacity, power, and energy efficiency ratio (EER) of an air conditioner were quantified. The air conditioner was subjected to an outdoor temperature of 100°F (37.g°C). The indoor conditions for the no leakage test were set at 75OF (23.g...

  10. Comparison of DOE-2.1E with Energyplus and TRNSYS for Ground Coupled Residential Buildings in Hot anf Humid Climates Stage 4

    E-Print Network [OSTI]

    Andolsun, S.; Culp, C.

    2012-01-01T23:59:59.000Z

    -on- grade heat transfer for International Energy Conservation Code (IECC) compliant low-rise 20m x 20m x 3m residential buildings with unconditioned attics in four U.S. climates (hot-humid, hot-dry, cold, and temperate). For the modeling of the slab... the requirements of IECC 2009. As a result, four energy code compliant fully loaded houses located in hot-humid (Austin), hot-dry (Phoenix), temperate (Chicago) and cold (Columbia Falls) climates were obtained. First, these houses were modeled with an adiabatic...

  11. Comparison of DOE-2.1E with Energyplus and TRNSYS for Ground Coupled Residential Buildings in Hot anf Humid Climates Stage 4 

    E-Print Network [OSTI]

    Andolsun, S.; Culp, C.

    2012-01-01T23:59:59.000Z

    -on- grade heat transfer for International Energy Conservation Code (IECC) compliant low-rise 20m x 20m x 3m residential buildings with unconditioned attics in four U.S. climates (hot-humid, hot-dry, cold, and temperate). For the modeling of the slab... the requirements of IECC 2009. As a result, four energy code compliant fully loaded houses located in hot-humid (Austin), hot-dry (Phoenix), temperate (Chicago) and cold (Columbia Falls) climates were obtained. First, these houses were modeled with an adiabatic...

  12. Variable temperature electrochemical strain microscopy of Sm-doped ceria

    SciTech Connect (OSTI)

    Jesse, Stephen [ORNL; Morozovska, A. N. [National Academy of Science of Ukraine, Kiev, Ukraine; Kalinin, Sergei V [ORNL; Eliseev, E. A. [National Academy of Science of Ukraine, Kiev, Ukraine; Yang, Nan [ORNL; Doria, Sandra [ORNL; Tebano, Antonello [ORNL

    2013-01-01T23:59:59.000Z

    Variable temperature electrochemical strain microscopy has been used to study the electrochemical activity of Sm-doped ceria as a function of temperature and bias. The electrochemical strain microscopy hysteresis loops have been collected across the surface at different temperatures and the relative activity at different temperatures has been compared. The relaxation behavior of the signal at different temperatures has been also evaluated to relate kinetic process during bias induced electrochemical reactions with temperature and two different kinetic regimes have been identified. The strongly non-monotonic dependence of relaxation behavior on temperature is interpreted as evidence for water-mediated mechanisms.

  13. Optimizing Cooling Tower Performance Refrigeration Systems, Chemical Plants, and Power Plants All Have A Resource Quietly Awaiting Exploitation-Cold Water!!

    E-Print Network [OSTI]

    Burger, R.

    requirements before a cooling tower is purchased. This relates to the volume of circulating water, hot water temperature on the tower, cold water discharge, and wet bulb temperature (consisting of ambient temperature and relative humidity). After the tower...

  14. Local temperature for dynamical black holes

    E-Print Network [OSTI]

    Sean A. Hayward; R. Di Criscienzo; M. Nadalini; L. Vanzo; S. Zerbini

    2008-12-13T23:59:59.000Z

    A local Hawking temperature was recently derived for any future outer trapping horizon in spherical symmetry, using a Hamilton-Jacobi tunneling method, and is given by a dynamical surface gravity as defined geometrically. Descriptions are given of the operational meaning of the temperature, in terms of what observers measure, and its relation to the usual Hawking temperature for static black holes. Implications for the final fate of an evaporating black hole are discussed.

  15. Apparatus and method for high temperature viscosity and temperature measurements

    DOE Patents [OSTI]

    Balasubramaniam, Krishnan (Mississippi State, MS); Shah, Vimal (Houston, TX); Costley, R. Daniel (Mississippi State, MS); Singh, Jagdish P. (Mississippi State, MS)

    2001-01-01T23:59:59.000Z

    A probe for measuring the viscosity and/or temperature of high temperature liquids, such as molten metals, glass and similar materials comprises a rod which is an acoustical waveguide through which a transducer emits an ultrasonic signal through one end of the probe, and which is reflected from (a) a notch or slit or an interface between two materials of the probe and (b) from the other end of the probe which is in contact with the hot liquid or hot melt, and is detected by the same transducer at the signal emission end. To avoid the harmful effects of introducing a thermally conductive heat sink into the melt, the probe is made of relatively thermally insulative (non-heat-conductive) refractory material. The time between signal emission and reflection, and the amplitude of reflections, are compared against calibration curves to obtain temperature and viscosity values.

  16. Cooled, temperature controlled electrometer

    DOE Patents [OSTI]

    Morgan, John P. (Idaho Falls, ID)

    1992-01-01T23:59:59.000Z

    A cooled, temperature controlled electrometer for the measurement of small currents. The device employs a thermal transfer system to remove heat from the electrometer circuit and its environment and dissipate it to the external environment by means of a heat sink. The operation of the thermal transfer system is governed by a temperature regulation circuit which activates the thermal transfer system when the temperature of the electrometer circuit and its environment exceeds a level previously inputted to the external variable temperature control circuit. The variable temperature control circuit functions as subpart of the temperature control circuit. To provide temperature stability and uniformity, the electrometer circuit is enclosed by an insulated housing.

  17. Cooled, temperature controlled electrometer

    DOE Patents [OSTI]

    Morgan, John P.

    1992-08-04T23:59:59.000Z

    A cooled, temperature controlled electrometer for the measurement of small currents. The device employs a thermal transfer system to remove heat from the electrometer circuit and its environment and dissipate it to the external environment by means of a heat sink. The operation of the thermal transfer system is governed by a temperature regulation circuit which activates the thermal transfer system when the temperature of the electrometer circuit and its environment exceeds a level previously inputted to the external variable temperature control circuit. The variable temperature control circuit functions as subpart of the temperature control circuit. To provide temperature stability and uniformity, the electrometer circuit is enclosed by an insulated housing.

  18. Temperature and electrical memory of polymer fibers

    SciTech Connect (OSTI)

    Yuan, Jinkai; Zakri, Cécile; Grillard, Fabienne; Neri, Wilfrid; Poulin, Philippe [Centre de Recherche Paul Pascal - CNRS, University of Bordeaux, Avenue Schweitzer, 33600 Pessac (France)

    2014-05-15T23:59:59.000Z

    We report in this work studies of the shape memory behavior of polymer fibers loaded with carbon nanotubes or graphene flakes. These materials exhibit enhanced shape memory properties with the generation of a giant stress upon shape recovery. In addition, they exhibit a surprising temperature memory with a peak of generated stress at a temperature nearly equal to the temperature of programming. This temperature memory is ascribed to the presence of dynamical heterogeneities and to the intrinsic broadness of the glass transition. We present recent experiments related to observables other than mechanical properties. In particular nanocomposite fibers exhibit variations of electrical conductivity with an accurate memory. Indeed, the rate of conductivity variations during temperature changes reaches a well defined maximum at a temperature equal to the temperature of programming. Such materials are promising for future actuators that couple dimensional changes with sensing electronic functionalities.

  19. Analysis of Energy, Environmental and Life Cycle Cost Reduction Potential of Ground Source Heat Pump (GSHP) in Hot and Humid Climate

    Broader source: Energy.gov [DOE]

    Project objectives: Gather and analyze independently the available technical, cost, financial incentive data on installed GSHP/HGSHP applications in residential, commercial and schools in hot and humid climate regions, and develop a calibrated baseline and performance period model of new construction and retrofitted buildings in conjunction with the energy simulation program.

  20. australian tropical savannas: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    results in warmer and drier climate of tropical savannas increases temperatures and wind speeds and decreases precipitation and relative humidity Jackson, Robert B. 2...

  1. Plant Physiology Data, Barrow, Alaska, 2013

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Alistair Rogers

    Survey measurements of photosynthetic rate and stomatal conductance together with carbon dioxide concentration, temperature, PAR, and relative humidity for 8 species on the BEO.

  2. Climatically Diverse Data Set for Flat-Plate PV Module Model...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    o Direct normal, diffuse and global horiz. irradiance o Wind speed and direction; dry bulb temperature; relative humidity; barometric pressure; precipitation 7 Daily Operations *...

  3. Integrated Emissivity And Temperature Measurement

    DOE Patents [OSTI]

    Poulsen, Peter (Livermore, CA)

    2005-11-08T23:59:59.000Z

    A multi-channel spectrometer and a light source are used to measure both the emitted and the reflected light from a surface which is at an elevated temperature relative to its environment. In a first method, the temperature of the surface and emissivity in each wavelength is calculated from a knowledge of the spectrum and the measurement of the incident and reflected light. In the second method, the reflected light is measured from a reference surface having a known reflectivity and the same geometry as the surface of interest and the emitted and the reflected light are measured for the surface of interest. These measurements permit the computation of the emissivity in each channel of the spectrometer and the temperature of the surface of interest.

  4. Bay Ridge Gardens - Mixed-Humid Affordable Multifamily Housing Deep Energy Retrofit

    SciTech Connect (OSTI)

    Lyons, J.; Moore, M.; Thompson, M.

    2013-08-01T23:59:59.000Z

    Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a 'base scope' retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a 'DER scope' which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

  5. The temperature dependence of equilibrium plasma density

    E-Print Network [OSTI]

    B. V. Vasiliev

    2002-03-17T23:59:59.000Z

    Temperature dependence of an electron-nuclear plasma equilibrium density is considered basing on known approaches, which are given in (1)(2). It is shown that at a very high temperature, which is characteristic for a star interior, the equilibrium plasma density is almost constant and equals approximately to $10^{25}$ particles per $cm^3$. At a relatively low temperature, which is characteristic for star surface, the equilibrium plasma density is in several orders lower and depends on temperature as $T^{3/2}$.

  6. Achieving Challenge Home in Affordable Housing in the Hot-Humid Climate

    SciTech Connect (OSTI)

    Beal, D.; McIlvaine, J.; Winter, B.; Allnutt, R.

    2014-08-01T23:59:59.000Z

    The Building America Partnership for Improved Residential Construction (BA-PIRC), one of the Building America research team leads, has partnered with two builders as they work through the Challenge Home certification process in one test home each. The builder partners participating in this cost-shared research are Southeast Volusia County Habitat for Humanity near Daytona, Florida and Manatee County Habitat for Humanity near Tampa, Florida. Both are affiliates of Habitat for Humanity International, a non-profit affordable housing organization. This research serves to identify viable technical pathways to meeting the CH criteria for other builders in the region. A further objective of this research is to identify gaps and barriers in the marketplace related to product availability, labor force capability, code issues, cost effectiveness, and business case issues that hinder or prevent broader adoption on a production scale.

  7. THE TEMPERATURES OF RED SUPERGIANTS

    SciTech Connect (OSTI)

    Davies, Ben [Astrophysics Research Institute, Liverpool John Moores University, Egerton Wharf, Birkenhead CH41 1LD (United Kingdom)] [Astrophysics Research Institute, Liverpool John Moores University, Egerton Wharf, Birkenhead CH41 1LD (United Kingdom); Kudritzki, Rolf-Peter; Gazak, Zach [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States)] [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States); Plez, Bertrand [Laboratoire Univers et Particules de Montpellier, Universite Montpellier 2, CNRS, F-34095 Montpellier (France)] [Laboratoire Univers et Particules de Montpellier, Universite Montpellier 2, CNRS, F-34095 Montpellier (France); Trager, Scott [Kapteyn Institute, University of Groningen, P.O. Box 800, 9700-AV Groningen (Netherlands)] [Kapteyn Institute, University of Groningen, P.O. Box 800, 9700-AV Groningen (Netherlands); Lancon, Ariane [Observatoire Astronomique and CNRS UMR 7550, Universite de Strasbourg, F-67000 Strasbourg (France)] [Observatoire Astronomique and CNRS UMR 7550, Universite de Strasbourg, F-67000 Strasbourg (France); Bergemann, Maria [Max-Planck-Institute for Astrophysics, Karl-Schwarzschild-Str. 1, D-85741 Garching (Germany)] [Max-Planck-Institute for Astrophysics, Karl-Schwarzschild-Str. 1, D-85741 Garching (Germany); Evans, Chris [UK Astronomy Technology Centre, Royal Observatory Edinburgh, Blackford Hill, Edinburgh EH9 3HJ (United Kingdom)] [UK Astronomy Technology Centre, Royal Observatory Edinburgh, Blackford Hill, Edinburgh EH9 3HJ (United Kingdom); Chiavassa, Andrea [CNRS Laboratoire Lagrange, Universite de Nice Sophia-Antipolis, Observatoire de la Cote d'Azur, BP 4229, F-06304 Nice Cedex 4 (France)] [CNRS Laboratoire Lagrange, Universite de Nice Sophia-Antipolis, Observatoire de la Cote d'Azur, BP 4229, F-06304 Nice Cedex 4 (France)

    2013-04-10T23:59:59.000Z

    We present a re-appraisal of the temperatures of red supergiants (RSGs) using their optical and near-infrared spectral energy distributions (SEDs). We have obtained data of a sample of RSGs in the Magellanic Clouds using VLT+XSHOOTER, and we fit MARCS model atmospheres to different regions of the spectra, deriving effective temperatures for each star from (1) the TiO bands, (2) line-free continuum regions of the SEDs, and (3) the integrated fluxes. We show that the temperatures derived from fits to the TiO bands are systematically lower than the other two methods by several hundred kelvin. The TiO fits also dramatically overpredict the flux in the near-IR, and imply extinctions which are anomalously low compared to neighboring stars. In contrast, the SED temperatures provide good fits to the fluxes at all wavelengths other than the TiO bands, are in agreement with the temperatures from the flux integration method, and imply extinctions consistent with nearby stars. After considering a number of ways to reconcile this discrepancy, we conclude that three-dimensional effects (i.e., granulation) are the most likely cause, as they affect the temperature structure in the upper layers where the TiO lines form. The continuum, however, which forms at much deeper layers, is apparently more robust to such effects. We therefore conclude that RSG temperatures are much warmer than previously thought. We discuss the implications of this result for stellar evolution and supernova progenitors, and provide relations to determine the bolometric luminosities of RSGs from single-band photometry.

  8. Strings at finite temperature

    SciTech Connect (OSTI)

    Arago C. de; Bazeia, D.; Eboli, O.J.P.; Marques, G.C.

    1985-12-15T23:59:59.000Z

    We obtain a semiclassical evaluation of the temperature for which the free energy of the strings of spontaneously broken scalar electrodynamics vanishes. We argue that, above this temperature, these objects should play a significant physical role.

  9. Improvements in Shallow (Two-Meter) Temperature Measurements...

    Open Energy Info (EERE)

    to study influences on shallow temperature measurements related to geological and solar radiation factors specifically, slope orientation, ground composition and albedo. In...

  10. Complementary Relativity

    E-Print Network [OSTI]

    P. F. Gonzalez-Diaz

    1994-04-07T23:59:59.000Z

    Special theory of relativity has been formulated in a vacuum momentum-energy representation which is equivalent to Einstein special relativity and predicts just the same results as it. Although in this sense such a formulation would be at least classically useless, its consistent extension to noninertial frames produces a momentum-energy metric which behaves as a new dynamical quantity that is here interpreted in terms of a cosmological field. This new field would be complementary to gravity in that its strength varies inversely to as that of gravity does. Using a strong-field approximation, we suggest that the existence of this cosmological field would induce a shift of luminous energy which could justify the existence of all the assumed invisible matter in the universe, so as the high luminousities found in active galactic nuclei and quasars.

  11. Effect of deposition times on structure of Ga-doped ZnO thin films as humidity sensor

    SciTech Connect (OSTI)

    Khalid, Faridzatul Shahira; Awang, Rozidawati [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia)

    2014-09-03T23:59:59.000Z

    Gallium doped zinc oxide (GZO) has good electrical property. It is widely used as transparent electrode in photovoltaic devices, and sensing element in gas and pressure sensors. GZO thin film was prepared using magnetron sputtering. Film deposition times were set at 10, 15, 20, 25 and 30 minutes to get samples of different thickness. X-ray diffraction (XRD) was used to determine the structure of GZO thin films. Structure for GZO thin film is hexagonal wurtzite structure. Morphology and thickness of GZO thin films was observed from FESEM micrographs. Grain size and thickness of thin films improved with increasing deposition times. However, increasing the thickness of thin films occur below 25 minutes only. Electrical properties of GZO thin films were studied using a four-point probe technique. The changes in the structure of the thin films lead to the changed of their electrical properties resulting in the reduction of the film resistance. These thin films properties significantly implying the potential application of the sample as a humidity sensor.

  12. Performance Verification of Production-Scalable Energy-Efficient Solutions: Winchester/Camberley Homes Mixed-Humid Climate

    SciTech Connect (OSTI)

    Mallay, D.; Wiehagen, J.

    2014-07-01T23:59:59.000Z

    Winchester/Camberley Homes with the Building America program and its NAHB Research Center Industry Partnership collaborated to develop a new set of high performance home designs that could be applicable on a production scale. The new home designs are to be constructed in the mixed humid climate zone four and could eventually apply to all of the builder's home designs to meet or exceed future energy codes or performance-based programs. However, the builder recognized that the combination of new wall framing designs and materials, higher levels of insulation in the wall cavity, and more detailed air sealing to achieve lower infiltration rates changes the moisture characteristics of the wall system. In order to ensure long term durability and repeatable successful implementation with few call-backs, this report demonstrates through measured data that the wall system functions as a dynamic system, responding to changing interior and outdoor environmental conditions within recognized limits of the materials that make up the wall system. A similar investigation was made with respect to the complete redesign of the heating, cooling, air distribution, and ventilation systems intended to optimize the equipment size and configuration to significantly improve efficiency while maintaining indoor comfort. Recognizing the need to demonstrate the benefits of these efficiency features, the builder offered a new house model to serve as a test case to develop framing designs, evaluate material selections and installation requirements, changes to work scopes and contractor learning curves, as well as to compare theoretical performance characteristics with measured results.

  13. Integrated and Optimized Energy-Efficient Construction Package for a Community of Production Homes in the Mixed-Humid Climate

    SciTech Connect (OSTI)

    Mallay, D.; Wiehagen, J.; Del Bianco, M.

    2014-10-01T23:59:59.000Z

    Selection and integration of high performance home features are two sides of the same coin in energy efficient sustainable construction. Many advanced technologies are available for selection, but it is in the integration of these technologies into an affordable set of features that can be used on a production basis by builders, that ensures whole-house performance meets expectations. This research high performance home analyzes how a set of advanced technologies can be integrated into a durable and energy efficient house in the mixed-humid climate while remaining affordable to homeowners. The technical solutions documented in this report are the cornerstone of the builder's entire business model based on delivering high-performance homes on a production basis as a standard product offering to all price segments of the residential market. Home Innovation Research Labs partnered with production builder Nexus EnergyHomes (CZ 4). The builder plans to adopt the successful components of the energy solution package for all 55 homes in the community. The research objective was to optimize the builder's energy solution package based on energy performance and construction costs. All of the major construction features, including envelope upgrades, space conditioning system, hot water system, and solar electric system were analyzed. The information in this report can be used by builders and designers to evaluate options, and the integration of options, for increasing the efficiency of home designs in climate zone 4. The data also provide a point of reference for evaluating estimates of energy savings and costs for specific features.

  14. Temperature compensated photovoltaic array

    DOE Patents [OSTI]

    Mosher, D.M.

    1997-11-18T23:59:59.000Z

    A temperature compensated photovoltaic module comprises a series of solar cells having a thermally activated switch connected in parallel with several of the cells. The photovoltaic module is adapted to charge conventional batteries having a temperature coefficient differing from the temperature coefficient of the module. The calibration temperatures of the switches are chosen whereby the colder the ambient temperature for the module, the more switches that are on and form a closed circuit to short the associated solar cells. By shorting some of the solar cells as the ambient temperature decreases, the battery being charged by the module is not excessively overcharged at lower temperatures. PV module is an integrated solution that is reliable and inexpensive. 2 figs.

  15. Temperature compensated photovoltaic array

    DOE Patents [OSTI]

    Mosher, Dan Michael (Plano, TX)

    1997-11-18T23:59:59.000Z

    A temperature compensated photovoltaic module (20) comprised of a series of solar cells (22) having a thermally activated switch (24) connected in parallel with several of the cells (22). The photovoltaic module (20) is adapted to charge conventional batteries having a temperature coefficient (TC) differing from the temperature coefficient (TC) of the module (20). The calibration temperatures of the switches (24) are chosen whereby the colder the ambient temperature for the module (20), the more switches that are on and form a closed circuit to short the associated solar cells (22). By shorting some of the solar cells (22) as the ambient temperature decreases, the battery being charged by the module (20) is not excessively overcharged at lower temperatures. PV module (20) is an integrated solution that is reliable and inexpensive.

  16. The temperature market A stochastic model for temperature

    E-Print Network [OSTI]

    Pfeifer, Holger

    The temperature market A stochastic model for temperature Temperature futures Conclusions The Volatility of Temperature and Pricing of Weather Derivatives Fred Espen Benth Work in collaboration with J Universit¨at Ulm, April 2007 #12;The temperature market A stochastic model for temperature Temperature

  17. Kinetics of combustion related processes at high temperatures

    SciTech Connect (OSTI)

    Kiefer, J.H. [Univ. of Illinois, Chicago (United States)

    1993-12-01T23:59:59.000Z

    This past year has seen an excursion into perhalomethane dissociation using the laser-schlieren (LS) technique, with work on CCl{sub 4} already published and on CF{sub 3}Cl under analysis. However, the author`s emphasis has again been on the study of relaxation and dissociation of large molecules using the converging/diverging nozzle method to generate very weak (low pressure) shock waves.

  18. Related Links

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOnItemResearch > TheNuclear Press Releases 2014References by Websitehome / Related Links

  19. Automatic temperature adjustment apparatus

    DOE Patents [OSTI]

    Chaplin, James E. (66 Overlook Rd., Bloomingdale, NJ 07403)

    1985-01-01T23:59:59.000Z

    An apparatus for increasing the efficiency of a conventional central space heating system is disclosed. The temperature of a fluid heating medium is adjusted based on a measurement of the external temperature, and a system parameter. The system parameter is periodically modified based on a closed loop process that monitors the operation of the heating system. This closed loop process provides a heating medium temperature value that is very near the optimum for energy efficiency.

  20. Equilibrium temperature anisotropy and black-hole analogues

    E-Print Network [OSTI]

    Daniel K. L. Oi; Jonathan Oppenheim

    2007-02-01T23:59:59.000Z

    When long-range interactions are present the usual definition of temperature implies that two systems in thermal equilibrium can be at different temperatures. This local temperature has physical significance, if the sub-systems cease to interact, each system will be at their different local temperatures. This is formally related to redshifting of temperature in general relativity. We propose experiments to test this effect which are feasible using current microfabrication techniques. It is also possible to display thermodynamical analogues to black-hole space-time.

  1. Low temperature joining of ceramic composites

    DOE Patents [OSTI]

    Barton, Thomas J. (Ames, IA); Anderson, Iver E. (Ames, IA); Ijadi-Maghsoodi, Sina (Ames, IA); Nosrati, Mohammad (Ames, IA); Unal, Ozer (Ames, IA)

    2001-04-10T23:59:59.000Z

    A method of joining similar or dissimilar ceramic and ceramic composite materials, such as SiC continuous fiber ceramic composites, at relatively low joining temperatures uses a solventless, three component bonding agent effective to promote mechanical bond toughness and elevated temperature strength to operating temperatures of approximately 1200 degrees C. The bonding agent comprises a preceramic precursor, an aluminum bearing powder, such as aluminum alloy powder, and mixtures of aluminum metal or alloy powders with another powder, and and boron powder in selected proportions. The bonding agent is disposed as an interlayer between similar or dissimilar ceramic or cermaic composite materials to be joined and is heated in ambient air or inert atmosphere to a temperature not exceeding about 1200 degrees C. to form a strong and tough bond joint between the materials. The bond joint produced is characterized by a composite joint microstructure having relatively soft, compliant aluminum bearing particulate regions dispersed in a ceramic matrix.

  2. Low temperature joining of ceramic composites

    DOE Patents [OSTI]

    Barton, T.J.; Anderson, I.E.; Ijadi-Maghsoodi, S.; Nosrati, M.; Unal, O.

    1999-01-12T23:59:59.000Z

    A method of joining similar or dissimilar ceramic and ceramic composite materials, such as SiC continuous fiber ceramic composites, at relatively low joining temperatures uses a solventless, three component bonding agent effective to promote mechanical bond toughness and elevated temperature strength to operating temperatures of approximately 1200 degrees C. The bonding agent comprises a preceramic precursor, an aluminum bearing powder, such as aluminum alloy powder, and mixtures of aluminum metal or alloy powders with another powder, and boron powder in selected proportions. The bonding agent is disposed as an interlayer between similar or dissimilar ceramic or ceramic composite materials to be joined and is heated in ambient air or inert atmosphere to a temperature not exceeding about 1200 degrees C. to form a strong and tough bond joint between the materials. The bond joint produced is characterized by a composite joint microstructure having relatively soft, compliant aluminum bearing particulate regions dispersed in a ceramic matrix. 3 figs.

  3. Low temperature joining of ceramic composites

    DOE Patents [OSTI]

    Barton, Thomas J. (Ames, IA); Anderson, Iver E. (Ames, IA); Ijadi-Maghsoodi, Sina (Ames, IA); Nosrati, Mohammad (Ames, IA); Unal, Ozer (Ames, IA)

    1999-07-13T23:59:59.000Z

    A method of joining similar or dissimilar ceramic and ceramic composite materials, such as SiC continuous fiber ceramic composites, at relatively low joining temperatures uses a solventless, three component bonding agent effective to promote mechanical bond toughness and elevated temperature strength to operating temperatures of approximately 1200 degrees C. The bonding agent comprises a preceramic precursor, an aluminum bearing powder, such as aluminum alloy powder, and mixtures of aluminum metal or alloy powders with another powder, and and boron powder in selected proportions. The bonding agent is disposed as an interlayer between similar or dissimilar ceramic or ceramic composite materials to be joined and is heated in ambient air or inert atmosphere to a temperature not exceeding about 1200 degrees C. to form a strong and tough bond joint between the materials. The bond joint produced is characterized by a composite joint microstructure having relatively soft, compliant aluminum bearing particulate regions dispersed in a ceramic matrix.

  4. Low temperature joining of ceramic composites

    DOE Patents [OSTI]

    Barton, Thomas J. (Ames, IA); Anderson, Iver E. (Ames, IA); Ijadi-Maghsoodi, Sina (Ames, IA); Nosrati, Mohammad (Ames, IA); Unal, Ozer (Ames, IA)

    1999-01-12T23:59:59.000Z

    A method of joining similar or dissimilar ceramic and ceramic composite materials, such as SiC continuous fiber ceramic composites, at relatively low joining temperatures uses a solventless, three component bonding agent effective to promote mechanical bond toughness and elevated temperature strength to operating temperatures of approximately 1200 degrees C. The bonding agent comprises a preceramic precursor, an aluminum bearing powder, such as aluminum alloy powder, and mixtures of aluminum metal or alloy powders with another powder, and and boron powder in selected proportions. The bonding agent is disposed as an interlayer between similar or dissimilar ceramic or cermaic composite materials to be joined and is heated in ambient air or inert atmosphere to a temperature not exceeding about 1200 degrees C. to form a strong and tough bond joint between the materials. The bond joint produced is characterized by a composite joint microstructure having relatively soft, compliant aluminum bearing particulate regions dispersed in a ceramic matrix.

  5. Low temperature joining of ceramic composites

    DOE Patents [OSTI]

    Barton, T.J.; Anderson, I.E.; Ijadi-Maghsoodi, S.; Nosrati, M.; Unal, O.

    1999-07-13T23:59:59.000Z

    A method of joining similar or dissimilar ceramic and ceramic composite materials, such as SiC continuous fiber ceramic composites, at relatively low joining temperatures uses a solventless, three component bonding agent effective to promote mechanical bond toughness and elevated temperature strength to operating temperatures of approximately 1200 C. The bonding agent comprises a preceramic precursor, an aluminum bearing powder, such as aluminum alloy powder, and mixtures of aluminum metal or alloy powders with another powder, and boron powder in selected proportions. The bonding agent is disposed as an interlayer between similar or dissimilar ceramic or ceramic composite materials to be joined and is heated in ambient air or inert atmosphere to a temperature not exceeding about 1200 C to form a strong and tough bond joint between the materials. The bond joint produced is characterized by a composite joint microstructure having relatively soft, compliant aluminum bearing particulate regions dispersed in a ceramic matrix. 3 figs.

  6. Finite Temperature Gases of Fermionic Strings

    E-Print Network [OSTI]

    Shyamoli Chaudhuri

    2005-09-12T23:59:59.000Z

    We show that in the absence of a Ramond-Ramond sector both the type IIA and type IIB free string gases have a thermal instability due to low temperature tachyon modes. The gas of free IIA strings undergoes a thermal duality transition into a gas of free IIB strings at the self-dual temperature. The free heterotic string gas is a tachyon-free ensemble with gauge symmetry SO(16)$\\times$SO(16) in the presence of a timelike Wilson line background. It exhibits a holographic duality relation undergoing a self-dual phase transition with positive free energy and positive specific heat. The type IB open and closed string ensemble is related by thermal duality to the type I' string ensemble. We identify the order parameter for the Kosterlitz-Thouless phase transition from a low temperature gas of short open strings to a high temperature long string phase at or below T_C. Note Added (Sep 2005).

  7. Temperature and RH Targets

    Broader source: Energy.gov [DOE]

    Presented by Vishal O Mittal of the Florida Solar Energy Center at the High Temperature Membrane Working Group Meeting, San Francisco, September 14, 2006.

  8. Building America Best Practices Series Volume 15: 40% Whole-House Energy Savings in the Hot-Humid Climate

    SciTech Connect (OSTI)

    Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.; Cole, Pamala C.; Adams, Karen; Noonan, Christine F.

    2011-09-01T23:59:59.000Z

    This best practices guide is the 15th in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-humid climate can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and those requirements are highlighted in the text. Requirements of the 2012 IECC and 2012 IRC are also noted in text and tables throughout the guide. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

  9. Building America Best Practices Series Volume 16: 40% Whole-House Energy Savings in the Mixed-Humid Climate

    SciTech Connect (OSTI)

    Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.; Cole, Pamala C.; Adams, Karen; Butner, Ryan S.; Ortiz, Sallie J.

    2011-09-01T23:59:59.000Z

    This best practices guide is the 16th in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the mixed-humid climate can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and those requirements are highlighted in the text. Requirements of the 2012 IECC and 2012 IRC are also noted in text and tables throughout the guide. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

  10. Climate and weather events can impact human health in many ways. Climate trends, such as warming temperatures and changes in precipitation patterns, can affect the distribution of waterborne and vector-borne

    E-Print Network [OSTI]

    and mortality. Providing access to relevant climate information is essential to understanding how climate trends. · Using relative humidity and wind speed data to study the relationship between fine particulate air pollution and daily mortality counts. NOAA's National Climatic Data Center Sectoral Engagement Fact Sheet

  11. Deformation of contour and Hawking temperature

    E-Print Network [OSTI]

    Chikun Ding; Jiliang Jing

    2010-01-19T23:59:59.000Z

    It was found that, in an isotropic coordinate system, the tunneling approach brings a factor of 1/2 for the Hawking temperature of a Schwarzschild black hole. In this paper, we address this kind of problem by studying the relation between the Hawking temperature and the deformation of integral contour for the scalar and Dirac particles tunneling. We find that correct Hawking temperature can be obtained exactly as long as the integral contour deformed corresponding to the radial coordinate transform if the transformation is a non-regular or zero function at the event horizon.

  12. Thermoelectric Temperature Control

    E-Print Network [OSTI]

    Saffman, Mark

    NOTE 201TM TECHNICAL Optimizing Thermoelectric Temperature Control Systems #12;2 May 1995 92-040000A © 1995 Wavelength Electronics, Inc. Thermoelectric coolers (TECs) are used in a variety understanding of thermal management techniques and carefully select the thermoelectric module, temperature

  13. University of Illinois Temperature Sensors

    SciTech Connect (OSTI)

    K. L. Davis; D. L. Knudson; J. L. Rempe; B. M. Chase

    2014-09-01T23:59:59.000Z

    This document summarizes background information and presents results related to temperature measurements in the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) University of Illinois Project 29609 irradiation. The objective of this test was to assess the radiation performance of ferritic alloys for advanced reactor applications. The FeCr-based alloy system is considered the lead alloy system for a variety of advanced reactor components and applications. Irradiations of FeCr alloy samples were performed using the Hydraulic Shuttle Irradiation System (HSIS) in the B-7 position and in a static capsule in the A-11 position of the ATR.

  14. Labor Relations

    Broader source: Energy.gov [DOE]

    Addressing Poor Performance What Happens if an Employee’s Performance is Below the Meets Expectations (ME) level? Any time during the appraisal period an employee demonstrates that he/she is performing below the ME level in at least one critical element, the Rating Official should contact his/her Human Resources Office for guidance and: •If performance is at the Needs Improvement (NI) level; issue the employee a Performance Assistance Plan (PAP); or •If performance is at the Fails to Meet Expectations (FME) level; issue the employee a Performance Improvement Plan (PIP). Department of Energy Headquarters and The National Treasury Employees Union (NTEU) Collective Bargaining Agreement The National Treasury Employees Union (NTEU) is the exclusive representative of bargaining unit employees at the Department of Energy Headquarters offices in the Washington DC metropolitan area. The terms and conditions of this agreement have been negotiated by DOE and NTEU, and prescribe their respective rights and obligations in matters related to conditions of employment. Headquarters 1187 Request For Payroll Deductions For Labor Organization Dues The Request for Payroll Deduction for Labor Organization Dues (SF-1187) permits eligible employees, who are members of the National Treasury Employees Union (NTEU), to authorize voluntary allotments from their compensation. Headquarters 1188 Cancellation Of Payroll Deductions For Labor Organization Dues The Cancellation of Payroll Deductions for Labor Organizations Dues (SF-1188) permits eligible employees, who are members of the National Treasury Employees Union (NTEU), to cancel dues allotments. The National Treasury Employees Union, Collective Bargaining Agreement, Article 9 – Dues Withholding This article is for the purpose of permitting eligible employees, who are members of the National Treasury Employees Union (NTEU), to authorize voluntary allotments from their compensation.

  15. 8 Equivalence Relations 8.1 Relations

    E-Print Network [OSTI]

    Gera, Ralucca

    8 Equivalence Relations 8.1 Relations 1. for sets A and B we define a relation from A to B have that if (a, b) R and (b, c) R then (a, c) R 8.3 Equivalence Relations 1. a relation is an equivalence relation if it is reflexive, symmetric and transitive 2. if a relation R on a set

  16. Novel room temperature ferromagnetic semiconductors

    SciTech Connect (OSTI)

    Gupta, Amita

    2004-11-01T23:59:59.000Z

    Today's information world, bits of data are processed by semiconductor chips, and stored in the magnetic disk drives. But tomorrow's information technology may see magnetism (spin) and semiconductivity (charge) combined in one 'spintronic' device that exploits both charge and 'spin' to carry data (the best of two worlds). Spintronic devices such as spin valve transistors, spin light emitting diodes, non-volatile memory, logic devices, optical isolators and ultra-fast optical switches are some of the areas of interest for introducing the ferromagnetic properties at room temperature in a semiconductor to make it multifunctional. The potential advantages of such spintronic devices will be higher speed, greater efficiency, and better stability at a reduced power consumption. This Thesis contains two main topics: In-depth understanding of magnetism in Mn doped ZnO, and our search and identification of at least six new above room temperature ferromagnetic semiconductors. Both complex doped ZnO based new materials, as well as a number of nonoxides like phosphides, and sulfides suitably doped with Mn or Cu are shown to give rise to ferromagnetism above room temperature. Some of the highlights of this work are discovery of room temperature ferromagnetism in: (1) ZnO:Mn (paper in Nature Materials, Oct issue, 2003); (2) ZnO doped with Cu (containing no magnetic elements in it); (3) GaP doped with Cu (again containing no magnetic elements in it); (4) Enhancement of Magnetization by Cu co-doping in ZnO:Mn; (5) CdS doped with Mn, and a few others not reported in this thesis. We discuss in detail the first observation of ferromagnetism above room temperature in the form of powder, bulk pellets, in 2-3 mu-m thick transparent pulsed laser deposited films of the Mn (<4 at. percent) doped ZnO. High-resolution transmission electron microscopy (HRTEM) and electron energy loss spectroscopy (EELS) spectra recorded from 2 to 200nm areas showed homogeneous distribution of Mn substituting for Zn a 2+ state in the ZnO lattice. Ferromagnetic Resonance (FMR) technique is used to confirm the existence of ferromagnetic ordering at temperatures as high as 425K. The ab initio calculations were found to be consistent with the observation of ferromagnetism arising from fully polarized Mn 2+ state. The key to observed room temperature ferromagnetism in this system is the low temperature processing, which prevents formation of clusters, secondary phases and the host ZnO from becoming n-type. The electronic structure of the same Mn doped ZnO thin films studied using XAS, XES and RIXS, revealed a strong hybridization between Mn 3d and O 2p states, which is an important characteristic of a Dilute magnetic Semiconductor (DMS). It is shown that the various processing conditions like sintering temperature, dopant concentration and the properties of precursors used for making of DMS have a great influence on the final properties. Use of various experimental techniques to verify the physical properties, and to understand the mechanism involved to give rise to ferromagnetism is presented. Methods to improve the magnetic moment in Mn doped ZnO are also described. New promising DMS materials (such as Cu doped ZnO are explored). The demonstrated new capability to fabricate powder, pellets, and thin films of room temperature ferromagnetic semiconductors thus makes possible the realization of a wide range of complex elements for a variety of new multifunctional phenomena related to Spintronic devices as well as magneto-optic components.

  17. High Temperature Capacitor Development

    SciTech Connect (OSTI)

    John Kosek

    2009-06-30T23:59:59.000Z

    The absence of high-temperature electronics is an obstacle to the development of untapped energy resources (deep oil, gas and geothermal). US natural gas consumption is projected to grow from 22 trillion cubic feet per year (tcf) in 1999 to 34 tcf in 2020. Cumulatively this is 607 tcf of consumption by 2020, while recoverable reserves using current technology are 177 tcf. A significant portion of this shortfall may be met by tapping deep gas reservoirs. Tapping these reservoirs represents a significant technical challenge. At these depths, temperatures and pressures are very high and may require penetrating very hard rock. Logistics of supporting 6.1 km (20,000 ft) drill strings and the drilling processes are complex and expensive. At these depths up to 50% of the total drilling cost may be in the last 10% of the well depth. Thus, as wells go deeper it is increasingly important that drillers are able to monitor conditions down-hole such as temperature, pressure, heading, etc. Commercial off-the-shelf electronics are not specified to meet these operating conditions. This is due to problems associated with all aspects of the electronics including the resistors and capacitors. With respect to capacitors, increasing temperature often significantly changes capacitance because of the strong temperature dependence of the dielectric constant. Higher temperatures also affect the equivalent series resistance (ESR). High-temperature capacitors usually have low capacitance values because of these dielectric effects and because packages are kept small to prevent mechanical breakage caused by thermal stresses. Electrolytic capacitors do not operate at temperatures above 150oC due to dielectric breakdown. The development of high-temperature capacitors to be used in a high-pressure high-temperature (HPHT) drilling environment was investigated. These capacitors were based on a previously developed high-voltage hybridized capacitor developed at Giner, Inc. in conjunction with a unique high-temperature electrolyte developed during the course of the program. During this program the feasibility of operating a high voltage hybridized capacitor at 230oC was demonstrated. Capacitor specifications were established in conjunction with potential capacitor users. A method to allow for capacitor operation at both ambient and elevated temperatures was demonstrated. The program was terminated prior to moving into Phase II due to a lack of cost-sharing funds.

  18. Finite Temperature Effective Actions

    E-Print Network [OSTI]

    Ashok Das; J. Frenkel

    2009-08-27T23:59:59.000Z

    We present, from first principles, a direct method for evaluating the exact fermion propagator in the presence of a general background field at finite temperature, which can be used to determine the finite temperature effective action for the system. As applications, we determine the complete one loop finite temperature effective actions for 0+1 dimensional QED as well as the Schwinger model. These effective actions, which are derived in the real time (closed time path) formalism, generate systematically all the Feynman amplitudes calculated in thermal perturbation theory and also show that the retarded (advanced) amplitudes vanish in these theories.

  19. High-Temperature Superconductivity

    ScienceCinema (OSTI)

    Peter Johnson

    2010-01-08T23:59:59.000Z

    Like astronomers tweaking images to gain a more detailed glimpse of distant stars, physicists at Brookhaven National Laboratory have found ways to sharpen images of the energy spectra in high-temperature superconductors ? materials that carry electrical c

  20. Penrose Well Temperatures

    SciTech Connect (OSTI)

    Christopherson, Karen

    2013-03-15T23:59:59.000Z

    Penrose Well Temperatures Geothermal waters have been encountered in several wells near Penrose in Fremont County, Colorado. Most of the wells were drilled for oil and gas exploration and, in a few cases, production. This ESRI point shapefile utilizes data from 95 wells in and around the Penrose area provided by the Colorado Oil and Gas Conservation Commission (COGCC) database at http://cogcc.state.co.us/ . Temperature data from the database were used to calculate a temperature gradient for each well. This information was then used to estimate temperatures at various depths. Projection: UTM Zone 13 NAD27 Extent: West -105.224871 East -105.027633 North 38.486269 South 38.259507 Originators: Colorado Oil and Gas Conservation Commission (COGCC) Karen Christopherson

  1. Temperature in the Throat

    E-Print Network [OSTI]

    Dariush Kaviani; Amir Esmaeil Mosaffa

    2015-03-06T23:59:59.000Z

    We study the temperature of extended objects in string theory. Rotating D-branes in warped Calabi-Yau throats have induced metrics with thermal horizons and Hawking temperatures a la Unruh effect. We solve the equations of motion for slow rotating probe branes and derive their induced metrics in the UV/IR solutions of warped conifold throats. Our analysis shows that horizons and temperatures of expected features form on the world volume of the rotating probe brane in terms of conserved charges in the UV solutions of the conifold throat. In certain limits, we find world volume horizons and temperatures of the form similar to those of rotating probes in the AdS throat.

  2. Effect of temperature on performance of {sup 3}He filled neutron proportional counters

    SciTech Connect (OSTI)

    Desai, Shraddha S., E-mail: ssdesai@barc.gov.in [Solid State Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India)

    2014-04-24T23:59:59.000Z

    Neutron detectors used for cosmic neutron monitoring and various other applications are mounted in hostile environment. It is essential for detectors to sustain extreme climatic conditions, such as extreme temperature and humidity. Effort is made to evaluate the performance of detectors in extreme temperature in terms of pulse height distribution and avalanche formation. Neutron detectors filled with {sup 3}He incorporate an additive gas with quantity optimized for a particular application. Measurements are performed on neutron detectors filled with {sup 3}He and stopping gases Kr and CF{sub 4}. Detector performance for these fill gas combinations in terms of pulse height distribution is evaluated. Gas gain and Diethorn gas constants measured and analyzed for the microscopic effect on pulse formation. Results from these investigations are presented.

  3. High temperature pressure gauge

    DOE Patents [OSTI]

    Echtler, J. Paul (Pittsburgh, PA); Scandrol, Roy O. (Library, PA)

    1981-01-01T23:59:59.000Z

    A high temperature pressure gauge comprising a pressure gauge positioned in fluid communication with one end of a conduit which has a diaphragm mounted in its other end. The conduit is filled with a low melting metal alloy above the diaphragm for a portion of its length with a high temperature fluid being positioned in the remaining length of the conduit and in the pressure gauge.

  4. Temperature measuring device

    DOE Patents [OSTI]

    Lauf, Robert J. (Oak Ridge, TN); Bible, Don W. (Clinton, TN); Sohns, Carl W. (Oak Ridge, TN)

    1999-01-01T23:59:59.000Z

    Systems and methods are described for a wireless instrumented silicon wafer that can measure temperatures at various points and transmit those temperature readings to an external receiver. The device has particular utility in the processing of semiconductor wafers, where it can be used to map thermal uniformity on hot plates, cold plates, spin bowl chucks, etc. without the inconvenience of wires or the inevitable thermal perturbations attendant with them.

  5. Analysis of Energy, Environmental and Life Cycle Cost Reduction Potential of Ground Source Heat Pump (GSHP) in Hot and Humid Climate

    SciTech Connect (OSTI)

    Yong X. Tao; Yimin Zhu

    2012-04-26T23:59:59.000Z

    It has been widely recognized that the energy saving benefits of GSHP systems are best realized in the northern and central regions where heating needs are dominant or both heating and cooling loads are comparable. For hot and humid climate such as in the states of FL, LA, TX, southern AL, MS, GA, NC and SC, buildings have much larger cooling needs than heating needs. The Hybrid GSHP (HGSHP) systems therefore have been developed and installed in some locations of those states, which use additional heat sinks (such as cooling tower, domestic water heating systems) to reject excess heat. Despite the development of HGSHP the comprehensive analysis of their benefits and barriers for wide application has been limited and often yields non-conclusive results. In general, GSHP/HGSHP systems often have higher initial costs than conventional systems making short-term economics unattractive. Addressing these technical and financial barriers call for additional evaluation of innovative utility programs, incentives and delivery approaches. From scientific and technical point of view, the potential for wide applications of GSHP especially HGSHP in hot and humid climate is significant, especially towards building zero energy homes where the combined energy efficient GSHP and abundant solar energy production in hot climate can be an optimal solution. To address these challenges, this report presents gathering and analyzing data on the costs and benefits of GSHP/HGSHP systems utilized in southern states using a representative sample of building applications. The report outlines the detailed analysis to conclude that the application of GSHP in Florida (and hot and humid climate in general) shows a good potential.

  6. Time-temperature equivalence in Martensite tempering

    SciTech Connect (OSTI)

    Hackenberg, Robert E. [Los Alamos National Laboratory; Thomas, Grant A. [CSM; Speer, John G. [CSM; Matlock, David K. [CSM; Krauss, George [CSM

    2008-06-16T23:59:59.000Z

    The relationship between time and temperature is of great consequence in many materials-related processes including the tempering of martensite. In 1945, Hollomon and Jaffe quantified the 'degree of tempering' as a function of both tempering time, t, and tempering temperature, T, using the expression, T(log t + c). Here, c is thought to be a material constant and appears to decrease linearly with increasing carbon content. The Hollomon-Jaffe tempering parameter is frequently cited in the literature. This work reviews the original derivation of the tempering parameter concept, and presents the use of the characteristics diffusion distance as an alternative time-temperature relationship during martensite tempering. During the tempering of martensite, interstitial carbon atoms diffuse to form carbides. In addition, austenite decomposes, dislocations and grain boundaries rearrange, associated with iron self diffusion. Since these are all diffusional processes, it is reasonable to expect the degree of tempering to relate to the extent of diffusion.

  7. High temperature ceramic composition for hydrogen retention

    DOE Patents [OSTI]

    Webb, R.W.

    1974-01-01T23:59:59.000Z

    A ceramic coating for H retention in fuel elements is described. The coating has relatively low thermal neutron cross section, is not readily reduced by H at 1500 deg F, is adherent to the fuel element base metal, and is stable at reactor operating temperatures. (JRD)

  8. Active radiometer for self-calibrated furnace temperature measurements

    DOE Patents [OSTI]

    Woskov, Paul P. (Bedford, MA); Cohn, Daniel R. (Chestnut Hill, MA); Titus, Charles H. (Newtown Square, PA); Wittle, J. Kenneth (Chester Springs, PA); Surma, Jeffrey E. (Kennewick, WA)

    1996-01-01T23:59:59.000Z

    Radiometer with a probe beam superimposed on its field-of-view for furnace temperature measurements. The radiometer includes a heterodyne millimeter/submillimeter-wave receiver including a millimeter/submillimeter-wave source for probing. The receiver is adapted to receive radiation from a surface whose temperature is to be measured. The radiation includes a surface emission portion and a surface reflection portion which includes the probe beam energy reflected from the surface. The surface emission portion is related to the surface temperature and the surface reflection portion is related to the emissivity of the surface. The simultaneous measurement of surface emissivity serves as a real time calibration of the temperature measurement.

  9. Temperature initiated passive cooling system

    DOE Patents [OSTI]

    Forsberg, C.W.

    1994-11-01T23:59:59.000Z

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature. 1 fig.

  10. Temperature initiated passive cooling system

    DOE Patents [OSTI]

    Forsberg, Charles W. (Oak Ridge, TN)

    1994-01-01T23:59:59.000Z

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature.

  11. Variable tunneling barriers in FEBID based PtC metal-matrix nanocomposites as a transducing element for humidity sensing

    E-Print Network [OSTI]

    such as high temperatures or special environments. In this study we demonstrate a new gas sensing concept based special reformation conditions after detection events, whereas non-polar species (O2, CO2, N2) produce the particles, which governs the final conductivity. The specific change of these dielectric properties

  12. Temperature Data Evaluation

    SciTech Connect (OSTI)

    Gillespie, David

    2003-03-01T23:59:59.000Z

    Groundwater temperature is sensitive to the competing processes of heat flow from below the advective transport of heat by groundwater flow. Because groundwater temperature is sensitive to conductive and advective processes, groundwater temperature may be utilized as a tracer to further constrain the uncertainty of predictions of advective radionuclide transport models constructed for the Nevada Test Site (NTS). Since heat transport, geochemical, and hydrologic models for a given area must all be consistent, uncertainty can be reduced by devaluing the weight of those models that do not match estimated heat flow. The objective of this study was to identify the quantity and quality of available heat flow data at the NTS. One-hundred-forty-five temperature logs from 63 boreholes were examined. Thirteen were found to have temperature profiles suitable for the determination of heat flow values from one or more intervals within the boreholes. If sufficient spatially distributed heat flow values are obtained, a heat transport model coupled to a hydrologic model may be used to reduce the uncertainty of a nonisothermal hydrologic model of the NTS.

  13. High temperature thermometric phosphors

    DOE Patents [OSTI]

    Allison, Stephen W. (Knoxville, TN); Cates, Michael R. (Oak Ridge, TN); Boatner, Lynn A. (Oak Ridge, TN); Gillies, George T. (Earlysville, VA)

    1999-03-23T23:59:59.000Z

    A high temperature phosphor consists essentially of a material having the general formula LuPO.sub.4 :Dy.sub.(x),Eu.sub.y) wherein: 0.1 wt %.ltoreq.x.ltoreq.20 wt % and 0.1 wt %.ltoreq.y.ltoreq.20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopent. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions.

  14. High temperature thermometric phosphors

    DOE Patents [OSTI]

    Allison, S.W.; Cates, M.R.; Boatner, L.A.; Gillies, G.T.

    1999-03-23T23:59:59.000Z

    A high temperature phosphor consists essentially of a material having the general formula LuPO{sub 4}:Dy{sub x},Eu{sub y} wherein: 0.1 wt % {<=} x {<=} 20 wt % and 0.1 wt % {<=} y {<=} 20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopant. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions. 2 figs.

  15. High-temperature Pump Monitoring - High-temperature ESP Monitoring...

    Broader source: Energy.gov (indexed) [DOE]

    7 4.4.4 High-temperature Pump Monitoring - High-temperature ESP Monitoring Presentation Number: 018 Investigator: Dhruva, Brindesh (Schlumberger Technology Corp.) Objectives: To...

  16. Temperature profile detector

    DOE Patents [OSTI]

    Tokarz, Richard D. (West Richland, WA)

    1983-01-01T23:59:59.000Z

    A temperature profile detector shown as a tubular enclosure surrounding an elongated electrical conductor having a plurality of meltable conductive segments surrounding it. Duplicative meltable segments are spaced apart from one another along the length of the enclosure. Electrical insulators surround these elements to confine molten material from the segments in bridging contact between the conductor and a second electrical conductor, which might be the confining tube. The location and rate of growth of the resulting short circuits between the two conductors can be monitored by measuring changes in electrical resistance between terminals at both ends of the two conductors. Additional conductors and separate sets of meltable segments operational at differing temperatures can be monitored simultaneously for measuring different temperature profiles.

  17. Temperature profile detector

    DOE Patents [OSTI]

    Tokarz, R.D.

    1983-10-11T23:59:59.000Z

    Disclosed is a temperature profile detector shown as a tubular enclosure surrounding an elongated electrical conductor having a plurality of meltable conductive segments surrounding it. Duplicative meltable segments are spaced apart from one another along the length of the enclosure. Electrical insulators surround these elements to confine molten material from the segments in bridging contact between the conductor and a second electrical conductor, which might be the confining tube. The location and rate of growth of the resulting short circuits between the two conductors can be monitored by measuring changes in electrical resistance between terminals at both ends of the two conductors. Additional conductors and separate sets of meltable segments operational at differing temperatures can be monitored simultaneously for measuring different temperature profiles. 8 figs.

  18. Temperature determination using pyrometry

    DOE Patents [OSTI]

    Breiland, William G. (Albuquerque, NM); Gurary, Alexander I. (Bridgewater, NJ); Boguslavskiy, Vadim (Princeton, NJ)

    2002-01-01T23:59:59.000Z

    A method for determining the temperature of a surface upon which a coating is grown using optical pyrometry by correcting Kirchhoff's law for errors in the emissivity or reflectance measurements associated with the growth of the coating and subsequent changes in the surface thermal emission and heat transfer characteristics. By a calibration process that can be carried out in situ in the chamber where the coating process occurs, an error calibration parameter can be determined that allows more precise determination of the temperature of the surface using optical pyrometry systems. The calibration process needs only to be carried out when the physical characteristics of the coating chamber change.

  19. Fluorescent temperature sensor

    DOE Patents [OSTI]

    Baker, Gary A [Los Alamos, NM; Baker, Sheila N [Los Alamos, NM; McCleskey, T Mark [Los Alamos, NM

    2009-03-03T23:59:59.000Z

    The present invention is a fluorescent temperature sensor or optical thermometer. The sensor includes a solution of 1,3-bis(1-pyrenyl)propane within a 1-butyl-1-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ionic liquid solvent. The 1,3-bis(1-pyrenyl)propane remains unassociated when in the ground state while in solution. When subjected to UV light, an excited state is produced that exists in equilibrium with an excimer. The position of the equilibrium between the two excited states is temperature dependent.

  20. Winchester/Camberley Homes New Construction Test House Design, Construction, and Short-Term Testing in a Mixed-Humid Climate

    SciTech Connect (OSTI)

    Mallav, D.; Wiehagen, J.; Wood, A.

    2012-10-01T23:59:59.000Z

    The NAHB Research Center partnered with production builder Winchester/Camberley Homes to build a DOE Building America New Construction Test House (NCTH). This single family, detached house, located in the mixed-humid climate zone of Silver Spring, MD, was completed in June 2011. The primary goal for this house was to improve energy efficiency by 30% over the Building America B10 benchmark by developing and implementing an optimized energy solutions package design that could be cost effectively and reliably constructed on a production basis using quality management practices. The intent of this report is to outline the features of this house, discuss the implementation of the energy efficient design, and report on short-term testing results. During the interactive design process of this project, numerous iterations of the framing, air sealing, insulation, and space conditioning systems were evaluated for energy performance, cost, and practical implementation. The final design featured numerous advanced framing techniques, high levels of insulation, and the HVAC system entirely within conditioned space. Short-term testing confirmed a very tight thermal envelope and efficient and effective heating and cooling. In addition, relevant heating, cooling, humidity, energy, and wall cavity moisture data will be collected and presented in a future long-term report.

  1. Heat transfer in theory of relativity

    E-Print Network [OSTI]

    A. Brotas; J. C. Fernandes

    2006-04-27T23:59:59.000Z

    The traditional Fourier equation just allows us to study the evolution of temperature in an "undeformable" bar. The search for its relativistic variant is a task which is expected to fail because in relativity there are no undeformable bars. Rigid bodies, in the sense of "as rigid as possible", are deformables. In this work we show how to write in relativity the system of equations necessary to study simultaneously deformation and temperature evolution along a rigid deformable bar. The solutions of the two simultaneous equations is discussed assuming convenient constitutive relations for the material. An application is presented.

  2. Transition temperature in QCD

    SciTech Connect (OSTI)

    Cheng, M.; Christ, N. H.; Mawhinney, R. D. [Physics Department, Columbia University, New York, New York 10027 (United States); Datta, S.; Jung, C.; Schmidt, C.; Umeda, T. [Physics Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Heide, J. van der; Kaczmarek, O.; Laermann, E.; Miao, C. [Fakultaet fuer Physik, Universitaet Bielefeld, D-33615 Bielefeld (Germany); Karsch, F. [Physics Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Fakultaet fuer Physik, Universitaet Bielefeld, D-33615 Bielefeld (Germany); Petreczky, P. [Physics Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); RIKEN-BNL Research Center, Brookhaven National Laboratory, Upton, New York 11973 (United States); Petrov, K. [Niels Bohr Institute, University of Copenhagen, Blegdamsvej 17, DK-2100 Copenhagen (Denmark)

    2006-09-01T23:59:59.000Z

    We present a detailed calculation of the transition temperature in QCD with two light and one heavier (strange) quark mass on lattices with temporal extent N{sub {tau}}=4 and 6. Calculations with improved staggered fermions have been performed for various light to strange quark mass ratios in the range, 0.05{<=}m-circumflex{sub l}/m-circumflex{sub s}{<=}0.5, and with a strange quark mass fixed close to its physical value. From a combined extrapolation to the chiral (m-circumflex{sub l}{yields}0) and continuum (aT{identical_to}1/N{sub {tau}}{yields}0) limits we find for the transition temperature at the physical point T{sub c}r{sub 0}=0.457(7) where the scale is set by the Sommer-scale parameter r{sub 0} defined as the distance in the static quark potential at which the slope takes on the value (dV{sub qq}(r)/dr){sub r=r{sub 0}}=1.65/r{sub 0}{sup 2}. Using the currently best known value for r{sub 0} this translates to a transition temperature T{sub c}=192(7)(4) MeV. The transition temperature in the chiral limit is about 3% smaller. We discuss current ambiguities in the determination of T{sub c} in physical units and also comment on the universal scaling behavior of thermodynamic quantities in the chiral limit.

  3. High temperature storage battery

    SciTech Connect (OSTI)

    Sammells, A.F.

    1988-06-07T23:59:59.000Z

    A high temperature electrochemical cell is described comprising: a solid-state divalent cation conducting electrolyte; a positive electrode in contact with the electrolyte; a solid-state negative electrode contacting a divalent cation conducting molten salt mediating agent providing ionic mediation between the solid-state negative electrode and the solid-state electrolyte.

  4. Low Temperature Performance Characterization

    Broader source: Energy.gov (indexed) [DOE]

    0.0036 0.0038 0.004 0.0042 Inverse Temperature, 1K Gen2 Electrodes and 1.2M LiPF6 in EC:EMC (3:7 ww) (BID 1935), 4.1V, 3 Sep. Gen2 Electrodes and 1.2M LiPF6 in EC:EMC (3:7 ww)...

  5. Localized temperature stability of low temperature cofired ceramics

    DOE Patents [OSTI]

    Dai, Steven Xunhu

    2013-11-26T23:59:59.000Z

    The present invention is directed to low temperature cofired ceramic modules having localized temperature stability by incorporating temperature coefficient of resonant frequency compensating materials locally into a multilayer LTCC module. Chemical interactions can be minimized and physical compatibility between the compensating materials and the host LTCC dielectrics can be achieved. The invention enables embedded resonators with nearly temperature-independent resonance frequency.

  6. Temperature Temperature is the physical property of a

    E-Print Network [OSTI]

    Alexeenko, Alina

    Temperature Temperature is the physical property of a system which underlines the common notion and said to be at the same temperature. If a thermometer is placed in a gas container then the thermal zero. #12;Temperature The energy exchange between gas and thermometer is through collisions of gas

  7. Introducing an Online Cooling Tower Performance Analysis Tool

    E-Print Network [OSTI]

    Muller, M.R.; Muller, M.B.; Rao, P.

    2012-01-01T23:59:59.000Z

    and variable nature of all of the factors that can influence performance; fan speed, wind speed, sump temperature, heat load, ambient temperature, relative humidity, etc. This can be overwhelming for a regular operator resulting in many cooling towers being set...

  8. Reduction of particle deposition on substrates using temperature gradient control

    DOE Patents [OSTI]

    Rader, Daniel J. (Albuquerque, NM); Dykhuizen, Ronald C. (Albuquerque, NM); Geller, Anthony S. (Albuquerque, NM)

    2000-01-01T23:59:59.000Z

    A method of reducing particle deposition during the fabrication of microelectronic circuitry is presented. Reduction of particle deposition is accomplished by controlling the relative temperatures of various parts of the deposition system so that a large temperature gradient near the surface on which fabrication is taking place exists. This temperature gradient acts to repel particles from that surface, thereby producing cleaner surfaces, and thus obtaining higher yields from a given microelectronic fabrication process.

  9. Role of substrate temperature at graphene synthesis in arc discharge

    E-Print Network [OSTI]

    Fang, Xiuqi; Keidar, Michael

    2015-01-01T23:59:59.000Z

    Substrate temperature required for synthesis of graphene in arc discharge plasma was studied. It was shown that increase of the copper substrate temperature up to melting point leads to increase in the amount of graphene production and quality of graphene sheets. Favorable range of substrate temperatures for arc-based graphene synthesis was determined in relatively narrow range of about 1340-1360K which is near the melting point of copper.

  10. Determination of the Relative Amount of Fluorine in Uranium Oxyfluoride Particles using Secondary Ion Mass Spectrometry and Optical Spectroscopy

    SciTech Connect (OSTI)

    Kips, R; Kristo, M J; Hutcheon, I D; Amonette, J; Wang, Z; Johnson, T; Gerlach, D; Olsen, K B

    2009-05-29T23:59:59.000Z

    Both nuclear forensics and environmental sampling depend upon laboratory analysis of nuclear material that has often been exposed to the environment after it has been produced. It is therefore important to understand how those environmental conditions might have changed the chemical composition of the material over time, particularly for chemically sensitive compounds. In the specific case of uranium enrichment facilities, uranium-bearing particles stem from small releases of uranium hexafluoride, a highly reactive gas that hydrolyzes upon contact with moisture from the air to form uranium oxyfluoride (UO{sub 2}F{sub 2}) particles. The uranium isotopic composition of those particles is used by the International Atomic Energy Agency (IAEA) to verify whether a facility is compliant with its declarations. The present study, however, aims to demonstrate how knowledge of time-dependent changes in chemical composition, particle morphology and molecular structure can contribute to an even more reliable interpretation of the analytical results. We prepared a set of uranium oxyfluoride particles at the Institute for Reference Materials and Measurements (IRMM, European Commission, Belgium) and followed changes in their composition, morphology and structure with time to see if we could use these properties to place boundaries on the particle exposure time in the environment. Because the rate of change is affected by exposure to UV-light, humidity levels and elevated temperatures, the samples were subjected to varying conditions of those three parameters. The NanoSIMS at LLNL was found to be the optimal tool to measure the relative amount of fluorine in individual uranium oxyfluoride particles. At PNNL, cryogenic laser-induced time-resolved U(VI) fluorescence microspectroscopy (CLIFS) was used to monitor changes in the molecular structure.

  11. Division of Recreational Sports Visit us at www.recsports.wisc.edu

    E-Print Network [OSTI]

    Wisconsin at Madison, University of

    times you are exposed to higher temperatures. 3. Temperature Use the heat stress index table temp is relatively safe at 10 percent humidity, the heat stress of 90° F at 50 percent humidity is the equivalent of 96° F. When the heat stress index rises above 90° F, you may want to consider postponing your

  12. High Temperature Membrane Working Group

    Broader source: Energy.gov [DOE]

    This presentation provides an overview of the High Temperature Membrane Working Group Meeting in May 2007.

  13. The Temperature Prediction in Deepwater Drilling of Vertical Well

    E-Print Network [OSTI]

    Feng, Ming

    2012-07-16T23:59:59.000Z

    The extreme operating conditions in deepwater drilling lead to serious relative problems. The knowledge of subsea temperatures is of prime interest to petroleum engineers and geo-technologists alike. Petroleum engineers are interested in subsea...

  14. Temperature-Dependent Electron Transport in Quantum Dot Photovoltaics

    E-Print Network [OSTI]

    Padilla, Derek

    2013-01-01T23:59:59.000Z

    Paul Alivisatos. Photovoltaic performance of ultrasmall pbsenot including photovoltaic performance. To understand theperformance through overall structure and QD properties, relatively few studies probe the effects of temperature or capping ligands on the photovoltaic (

  15. Application of Reversible Chemical Reactions for Temperature Amplification 

    E-Print Network [OSTI]

    Ally, M. R.; Rebello, W. J.; Suciu, D. F.

    1985-01-01T23:59:59.000Z

    In a recent survey of 108 industries in the U.S., it was found that large amounts of thermal energy at relatively low temperatures was discharged to the atmosphere through industrial effluents. For the purpose of thermally ...

  16. Conformal Relativity: Theory and Observations

    E-Print Network [OSTI]

    V. Pervushin; V. Zinchuk; A. Zorin

    2004-11-22T23:59:59.000Z

    Theoretical and observational arguments are listed in favor of a new principle of relativity of units of measurements as the basis of a conformal-invariant unification of General Relativity and Standard Model by replacement of all masses with a scalar (dilaton) field. The relative units mean conformal observables: the coordinate distance, conformal time, running masses, and constant temperature. They reveal to us a motion of a universe along its hypersurface in the field space of events like a motion of a relativistic particle in the Minkowski space, where the postulate of the vacuum as a state with minimal energy leads to arrow of the geometric time. In relative units, the unified theory describes the Cold Universe Scenario, where the role of the conformal dark energy is played by a free minimal coupling scalar field in agreement with the most recent distance-redshift data from type Ia supernovae. In this Scenario, the evolution of the Universe begins with the effect of intensive creation of primordial W-Z-bosons explaining the value of CMBR temperature, baryon asymmetry, tremendous deficit of the luminosity masses in the COMA-type superclusters and large-scale structure of the Universe.

  17. Low Temperature Air Bake of Stainless Steel for Very Low

    E-Print Network [OSTI]

    that gives very hot water with detergent. #12;4. The method of using a relatively low temperature air bake of the requirements for high quality forged blanks for flanges. After machining using a water based lubricantLow Temperature Air Bake of Stainless Steel for Very Low Outgassing Rates Surface Conditioning

  18. Electrochemical Generation of Superoxide in Room-Temperature Ionic Liquids

    E-Print Network [OSTI]

    Weidner, John W.

    with an inorganic salt.7 They are directly related to more familiar high-temperature molten salts that are used by the reduction of dioxygen in imidizalium chloride-aluminum chloride molten salt. However, the resulting su and chlorides.2,3,6 Room-temperature ionic liquids RTILs are stable mixtures of an organic cation/anion salt

  19. Intermediate Temperature Solid Oxide Fuel Cell Development

    SciTech Connect (OSTI)

    S. Elangovan; Scott Barnett; Sossina Haile

    2008-06-30T23:59:59.000Z

    Solid oxide fuel cells (SOFCs) are high efficiency energy conversion devices. Present materials set, using yttria stabilized zirconia (YSZ) electrolyte, limit the cell operating temperatures to 800 C or higher. It has become increasingly evident however that lowering the operating temperature would provide a more expeditious route to commercialization. The advantages of intermediate temperature (600 to 800 C) operation are related to both economic and materials issues. Lower operating temperature allows the use of low cost materials for the balance of plant and limits degradation arising from materials interactions. When the SOFC operating temperature is in the range of 600 to 700 C, it is also possible to partially reform hydrocarbon fuels within the stack providing additional system cost savings by reducing the air preheat heat-exchanger and blower size. The promise of Sr and Mg doped lanthanum gallate (LSGM) electrolyte materials, based on their high ionic conductivity and oxygen transference number at the intermediate temperature is well recognized. The focus of the present project was two-fold: (a) Identify a cell fabrication technique to achieve the benefits of lanthanum gallate material, and (b) Investigate alternative cathode materials that demonstrate low cathode polarization losses at the intermediate temperature. A porous matrix supported, thin film cell configuration was fabricated. The electrode material precursor was infiltrated into the porous matrix and the counter electrode was screen printed. Both anode and cathode infiltration produced high performance cells. Comparison of the two approaches showed that an infiltrated cathode cells may have advantages in high fuel utilization operations. Two new cathode materials were evaluated. Northwestern University investigated LSGM-ceria composite cathode while Caltech evaluated Ba-Sr-Co-Fe (BSCF) based pervoskite cathode. Both cathode materials showed lower polarization losses at temperatures as low as 600 C than conventional manganite or cobaltite cathodes.

  20. Engine Cylinder Temperature Control

    DOE Patents [OSTI]

    Kilkenny, Jonathan Patrick (Peoria, IL); Duffy, Kevin Patrick (Metamora, IL)

    2005-09-27T23:59:59.000Z

    A method and apparatus for controlling a temperature in a combustion cylinder in an internal combustion engine. The cylinder is fluidly connected to an intake manifold and an exhaust manifold. The method and apparatus includes increasing a back pressure associated with the exhaust manifold to a level sufficient to maintain a desired quantity of residual exhaust gas in the cylinder, and varying operation of an intake valve located between the intake manifold and the cylinder to an open duration sufficient to maintain a desired quantity of fresh air from the intake manifold to the cylinder, wherein controlling the quantities of residual exhaust gas and fresh air are performed to maintain the temperature in the cylinder at a desired level.

  1. NGNP/HTE full-power operation at reduced high-temperature heat exchanger temperatures.

    SciTech Connect (OSTI)

    VIlim, R.; Nuclear Engineering Division

    2009-03-12T23:59:59.000Z

    Operation of the Next Generation Nuclear Plant (NGNP) with reduced reactor outlet temperature at full power was investigated for the High Temperature Electrolysis (HTE) hydrogen-production application. The foremost challenge for operation at design temperature is achieving an acceptably long service life for heat exchangers. In both the Intermediate Heat Exchanger (IHX) and the Process Heat Exchanger (PHX) (referred to collectively as high temperature heat exchangers) a pressure differential of several MPa exists with temperatures at or above 850 C. Thermal creep of the heat exchanger channel wall may severely limit heat exchanger life depending on the alloy selected. This report investigates plant performance with IHX temperatures reduced by lowering reactor outlet temperature. The objective is to lower the temperature in heat transfer channels to the point where existing materials can meet the 40 year lifetime needed for this component. A conservative estimate for this temperature is believed to be about 700 C. The reactor outlet temperature was reduced from 850 C to 700 C while maintaining reactor power at 600 MWt and high pressure compressor outlet at 7 MPa. We included a previously reported design option for reducing temperature at the PHX. Heat exchanger lengths were adjusted to reflect the change in performance resulting from coolant property changes and from resizing related to operating-point change. Turbomachine parameters were also optimized for the new operating condition. An integrated optimization of the complete system including heat transfer equipment was not performed. It is estimated, however, that by performing a pinch analysis the combined plant efficiency can be increased from 35.5 percent obtained in this report to a value between 38.5 and 40.1 percent. Then after normalizing for a more than three percent decrease in commodities inventory compared to the reference plant, the commodities-normalized efficiency lies between 40.0 and 41.3. This compares with a value of 43.9 for the reference plant. This latter plant has a reactor outlet temperature of 850 C and the two high temperature heat exchangers. The reduction in reactor outlet temperature from 850 C to 700 C reduces the tritium permeability rate in the IHX metal by a factor of three and thermal creep by five orders of magnitude. The design option for reducing PHX temperature from 800 C to 200 C reduces the permeability there by three orders of magnitude. In that design option this heat exchanger is the single 'choke-point' for tritium migration from the nuclear to the chemical plant.

  2. Low-Temperature Geothermal Resources, Geothermal Technologies Program (GTP) (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2010-05-01T23:59:59.000Z

    This document highlights the applications of low-temperature geothermal resources and the potential for future uses as well as current Geothermal Technologies Program-funded projects related to low-temperature resources.

  3. Holographic conductivity of zero temperature superconductors

    E-Print Network [OSTI]

    R. A. Konoplya; A. Zhidenko

    2010-02-15T23:59:59.000Z

    Using the recently found by G. Horowitz and M. Roberts (arXiv:0908.3677) numerical model of the ground state of holographic superconductors (at zero temperature), we calculate the conductivity for such models. The universal relation connecting conductivity with the reflection coefficient was used for finding the conductivity by the WKB approach. The dependence of the conductivity on the frequency and charge density is discussed. Numerical calculations confirm the general arguments of (arXiv:0908.3677) in favor of non-zero conductivity even at zero temperature. In addition to the Horowitz-Roberts solution we have found (probably infinite) set of extra solutions which are normalizable and reach the same correct RN-AdS asymptotic at spatial infinity. These extra solutions (which correspond to larger values of the grand canonical potential) lead to effective potentials that also vanish at the horizon and thus correspond to a non-zero conductivity at zero temperature.

  4. Mass and temperature limits for blackbody radiation

    E-Print Network [OSTI]

    Alessandro Pesci

    2006-03-24T23:59:59.000Z

    A spherically symmetric distribution of classical blackbody radiation is considered, at conditions in which gravitational self-interaction effects become not negligible. Static solutions to Einstein field equations are searched for, for each choice of the assumed central energy density. Spherical cavities at thermodynamic equilibrium, i.e. filled with blackbody radiation, are then studied, in particular for what concerns the relation among the mass M of the ball of radiation contained in them and their temperature at center and at the boundary. For these cavities it is shown, in particular, that: i) there is no absolute limit to M as well to their central and boundary temperatures; ii) when radius R is fixed, however, limits exist both for mass and for boundary energy density rho_B: M temperature) of the ball of radiation.

  5. RHIC 12x150A current lead temperature controller: design and implementation

    SciTech Connect (OSTI)

    Mi, C.; Seberg, S.; Ganetis, Hamdi, K.; Louie, W.; Heppner, G.; Jamilkowski, J.; Bruno, D.; DiLieto, A.; Sirio, C.; Tuozzolo, J.; Sandberg, J.; Unger, K.

    2011-03-28T23:59:59.000Z

    There are 60 12 x 150A current leads distributed in six RHIC service buildings; each lead delivers power supply current from room temperature to cryogenic temperature in RHIC. Due to the humid environment, condensation occurs frequently and ice forms quickly during operation, especially during an extensive storage period. These conditions generate warnings and alarms to which personnel must respond and establish temporary solutions to keep the machine operating. In here, we designed a temperature control system to avoid such situations. This paper discusses its design, implementation, and some results. There are six service buildings in the RHIC complex; each building has two valve boxes that transfer room-temperature current cables from the power supplies into superconducting leads, and then transport them into the RHIC tunnel. In there, the transition between the room-temperature lead into superconducting lead is critical and essential; smooth running during the physics store is crucial for the machine's continuing operation. One of the problems that often occurred previously was the icing of these current leads that could result in a potential leakage current onto ground, thereby preventing a continuous supply of physics store. Fig. 1 illustrates a typical example on a power lead. Among the modifications of the design of the valve box, we list below the new requirements for designing the temperature controller to prevent icing occurring: (1) Remotely control, monitor, and record each current lead's temperature in real time. Prevent icing or overheating of a power lead. (2) Include a temperature alarm for the high/low level threshold. In this paper we discuss the design, implementation, upgrades to, and operation of this new system.

  6. Simulation of Dehumidification Characteristics of High Efficiency Residential Central Air-Conditioners in Hot and Humid Climates

    E-Print Network [OSTI]

    Katipamula, S.; O'Neal, D.; Somasundram, S.

    1988-01-01T23:59:59.000Z

    ) thermostat set point and dead band, and (ill) sizing of unit relative to the design load of the residence. The units are evaluated on their ability to maintain conditions in the ASHRAE comfort zone in a typical residence in Houston area. The units...

  7. How and why electrostatic charge of combustible nanoparticles can radically change the mechanism and rate of their oxidation in humid atmosphere

    E-Print Network [OSTI]

    Meshcheryakov, Oleg

    2010-01-01T23:59:59.000Z

    Electrostatically charged aerosol nanoparticles strongly attract surrounding polar gas molecules due to a charge-dipole interaction. In humid air, the substantial electrostatic attraction and acceleration of surrounding water vapour molecules towards charged combustible nanoparticles cause intense electrostatic hydration and preferential oxidation of these nanoparticles by accelerated water vapor molecules rather than non-polar oxygen molecules. In particular, electrostatic acceleration, acquired by surrounding water vapour molecules at a distance of their mean free path from the minimally charged iron metal nanoparticle can increase an oxidative activity of these polar molecules with respect to the nanoparticle by a factor of one million. Intense electrostatic hydration of charged metal nanoparticles converts the nanoparticle's oxide based shells into the hydroxide based electrolyte shells, transforming these nanoparticles into metal/air core-shell nanobatteries, periodically short-circuited by intra-particl...

  8. Building America Residential System Research Results: Achieving 30% Whole House Energy Savings Level in Mixed-Humid Climates; January 2006 - December 2006

    SciTech Connect (OSTI)

    Building America Industrialized Housing Partnership (BAIHP); Building Industry Research Alliance (BIRA); Building Science Consortium (BSC); Consortium for Advanced Residential Buildings (CARB); Davis Energy Group (DEG); IBACOS; National Association of Home Builders Research Center (NAHBRC); National Renewable Energy Laboratory (NREL)

    2006-12-01T23:59:59.000Z

    The Building America program conducts the system research required to reduce risks associated with the design and construction of homes that use an average of 30% to 90% less total energy for all residential energy uses than the Building America Research Benchmark, including research on homes that will use zero net energy on annual basis. To measure the program's progress, annual research milestones have been established for five major climate regions in the United States. The system research activities required to reach each milestone take from 3 to 5 years to complete and include research in individual test houses, studies in pre-production prototypes, and research studies with lead builders that provide early examples that the specified energy savings level can be successfully achieved on a production basis. This report summarizes research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in the Mixed-Humid Climate Region on a cost-neutral basis.

  9. Evaluating Energy Performance and Improvement Potential of China Office Buildings in the Hot Humid Climate Against U.S. Reference Buildings: Preprint

    SciTech Connect (OSTI)

    Herrman, L.; Deru, M.; Zhai, J.

    2010-08-01T23:59:59.000Z

    This study compares the building code standards for office buildings in hot humid climates of China and the USA. A benchmark office building model is developed for Guangzhou, China that meets China's minimum national and regional building codes with incorporation of common design and construction practices for the area. The Guangzhou office benchmark model is compared to the ASHRAE standard based US model for Houston, Texas which has similar climate conditions. The research further uses a building energy optimization tool to optimize the Chinese benchmark with existing US products to identify the primary areas for potential energy savings. The most significant energy-saving options are then presented as recommendations for potential improvements to current China building codes.

  10. Building America Best Practices Series: Volume 4; Builders and Buyers Handbook for Improving New Home Efficiency, Comfort, and Durability in the Mixed-Humid Climate Climate Regions

    SciTech Connect (OSTI)

    Baechler, M. C.; Love, P. M.

    2005-09-01T23:59:59.000Z

    This best practices guide is part of a series produced by Building America. The guide book is a resource to help builders large and small build high-quality, energy-efficient homes that achieve 30% energy savings in space conditioning and water heating in the mixed-humid climate region. The savings are in comparison with the 1993 Model Energy Code. The guide contains chapters for every member of the builder?s team?from the manager to the site planner to the designers, site supervisors, the trades, and marketers. There is also a chapter for homeowners on how to use the book to provide help in selecting a new home or builder.

  11. Method for synthesizing extremely high-temperature melting materials

    DOE Patents [OSTI]

    Saboungi, Marie-Louise (Chicago, IL); Glorieux, Benoit (Perpignan, FR)

    2007-11-06T23:59:59.000Z

    The invention relates to a method of synthesizing high-temperature melting materials. More specifically the invention relates to a containerless method of synthesizing very high temperature melting materials such as carbides and transition-metal, lanthanide and actinide oxides, using an aerodynamic levitator and a laser. The object of the invention is to provide a method for synthesizing extremely high-temperature melting materials that are otherwise difficult to produce, without the use of containers, allowing the manipulation of the phase (amorphous/crystalline/metastable) and permitting changes of the environment such as different gaseous compositions.

  12. Method For Synthesizing Extremely High-Temperature Melting Materials

    DOE Patents [OSTI]

    Saboungi, Marie-Louise (Chicago, IL); Glorieux, Benoit (Perpignan, FR)

    2005-11-22T23:59:59.000Z

    The invention relates to a method of synthesizing high-temperature melting materials. More specifically the invention relates to a containerless method of synthesizing very high temperature melting materials such as borides, carbides and transition-metal, lanthanide and actinide oxides, using an Aerodynamic Levitator and a laser. The object of the invention is to provide a method for synthesizing extremely high-temperature melting materials that are otherwise difficult to produce, without the use of containers, allowing the manipulation of the phase (amorphous/crystalline/metastable) and permitting changes of the environment such as different gaseous compositions.

  13. Method for Synthesizing Extremeley High Temperature Melting Materials

    DOE Patents [OSTI]

    Saboungi, Marie-Louise and Glorieux, Benoit

    2005-11-22T23:59:59.000Z

    The invention relates to a method of synthesizing high-temperature melting materials. More specifically the invention relates to a containerless method of synthesizing very high temperature melting materials such as borides, carbides and transition-metal, lanthanide and actinide oxides, using an Aerodynamic Levitator and a laser. The object of the invention is to provide a method for synthesizing extremely high-temperature melting materials that are otherwise difficult to produce, without the use of containers, allowing the manipulation of the phase (amorphous/crystalline/metastable) and permitting changes of the environment such as different gaseous compositions.

  14. Thermionic Converter Temperature Controller

    SciTech Connect (OSTI)

    Shaner,B. J.; Wolf, Joseph H.; Johnson, Robert G. R.

    1999-08-23T23:59:59.000Z

    A method and apparatus for controlling the temperature of a thermionic reactor over a wide range of operating power, including a thermionic reactor having a plurality of integral cesium reservoirs, a honeycomb material disposed about the reactor which has a plurality of separated cavities, a solid sheath disposed about the honeycomb material and having an opening therein communicating with the honeycomb material and cavities thereof, and a shell disposed about the sheath for creating a coolant annulus therewith so that the coolant in the annulus may fill the cavities and permit nucleate boiling during the operation of the reactor.

  15. Thermionic converter temperature controller

    DOE Patents [OSTI]

    Shaner, Benjamin J. (McMurray, PA); Wolf, Joseph H. (Pittsburgh, PA); Johnson, Robert G. R. (Trafford, PA)

    2001-04-24T23:59:59.000Z

    A method and apparatus for controlling the temperature of a thermionic reactor over a wide range of operating power, including a thermionic reactor having a plurality of integral cesium reservoirs, a honeycomb material disposed about the reactor which has a plurality of separated cavities, a solid sheath disposed about the honeycomb material and having an opening therein communicating with the honeycomb material and cavities thereof, and a shell disposed about the sheath for creating a coolant annulus therewith so that the coolant in the annulus may fill the cavities and permit nucleate boiling during the operation of the reactor.

  16. Temperature | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro Industries PvtStratosolar Jump to:HoldingsTechint Spa JumpTVCEtTemperature" Showing 9

  17. Temperature Maps and Data

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal StocksProvedFeet)ThousandNumber andCrudeTemperature Maps and Data

  18. Temperature Maps and Data

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal StocksProvedFeet)ThousandNumber andCrudeTemperature Maps and

  19. Method And Apparatus For Evaluatin Of High Temperature Superconductors

    DOE Patents [OSTI]

    Fishman, Ilya M. (Palo Alto, CA); Kino, Gordon S. (Stanford, CA)

    1996-11-12T23:59:59.000Z

    A technique for evaluation of high-T.sub.c superconducting films and single crystals is based on measurement of temperature dependence of differential optical reflectivity of high-T.sub.c materials. In the claimed method, specific parameters of the superconducting transition such as the critical temperature, anisotropy of the differential optical reflectivity response, and the part of the optical losses related to sample quality are measured. The apparatus for performing this technique includes pump and probe sources, cooling means for sweeping sample temperature across the critical temperature and polarization controller for controlling a state of polarization of a probe light beam.

  20. Modeling the wet bulb globe temperature using standard meteorological measurements.

    SciTech Connect (OSTI)

    Liljegren, J. C.; Carhart, R. A.; Lawday, P.; Tschopp, S.; Sharp, R.; Decision and Information Sciences

    2008-10-01T23:59:59.000Z

    The U.S. Army has a need for continuous, accurate estimates of the wet bulb globe temperature to protect soldiers and civilian workers from heat-related injuries, including those involved in the storage and destruction of aging chemical munitions at depots across the United States. At these depots, workers must don protective clothing that increases their risk of heat-related injury. Because of the difficulty in making continuous, accurate measurements of wet bulb globe temperature outdoors, the authors have developed a model of the wet bulb globe temperature that relies only on standard meteorological data available at each storage depot for input. The model is composed of separate submodels of the natural wet bulb and globe temperatures that are based on fundamental principles of heat and mass transfer, has no site-dependent parameters, and achieves an accuracy of better than 1 C based on comparisons with wet bulb globe temperature measurements at all depots.

  1. The Greenhouse Effect Temperature Equilibrium

    E-Print Network [OSTI]

    Walter, Frederick M.

    The Greenhouse Effect #12;Temperature Equilibrium The Earth is in equilibrium with the Sun temperature is about 14C, or 287K. The 40K difference is due to the greenhouse effect. Essentially all

  2. Philosophy 26 High Temperature Superconductivity

    E-Print Network [OSTI]

    Callender, Craig

    Philosophy 26 High Temperature Superconductivity By Ohm's Law, resistance will dim. Low temperature superconductivity was discovered in 1911 by Heike was explained by BCS theory. BCS theory explains superconductivity microscopically

  3. Hot Pot Contoured Temperature Gradient Map

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Lane, Michael

    Temperature gradient contours derived from Oski temperature gradient hole program and from earlier published information.

  4. Hot Pot Contoured Temperature Gradient Map

    SciTech Connect (OSTI)

    Lane, Michael

    2013-06-28T23:59:59.000Z

    Temperature gradient contours derived from Oski temperature gradient hole program and from earlier published information.

  5. Concept of a thermonuclear reactor based on gravity retention of high-temperature plasma

    E-Print Network [OSTI]

    S. I. Fisenko; I. S. Fisenko

    2007-05-27T23:59:59.000Z

    In the present paper the realization of the obtained results in relation to the dense high- temperature plasma of multivalent ions including experimental data interpretation is discussed.

  6. Battery system with temperature sensors

    DOE Patents [OSTI]

    Wood, Steven J.; Trester, Dale B.

    2012-11-13T23:59:59.000Z

    A battery system to monitor temperature includes at least one cell with a temperature sensing device proximate the at least one cell. The battery system also includes a flexible member that holds the temperature sensor proximate to the at least one cell.

  7. HIGH TEMPERATURE HIGH PRESSURE THERMODYNAMIC MEASUREMENTS FOR COAL MODEL COMPOUNDS

    SciTech Connect (OSTI)

    Vinayak N. Kabadi

    1999-02-20T23:59:59.000Z

    It is well known that the fluid phase equilibria can be represented by a number of {gamma}-models , but unfortunately most of them do not function well under high temperature. In this calculation, we mainly investigate the performance of UNIQUAC and NRTL models under high temperature, using temperature dependent parameters rather than using the original formulas. the other feature of this calculation is that we try to relate the excess Gibbs energy G{sup E}and enthalpy of mixing H{sup E}simultaneously. In other words, we will use the high temperature and pressure G{sup E} and H{sup E}data to regress the temperature dependant parameters to find out which model and what kind of temperature dependant parameters should be used.

  8. Sonde Adjust Value-Added Product Technical Report

    SciTech Connect (OSTI)

    Troyan, D

    2012-01-09T23:59:59.000Z

    The Sonde Adjust (SONDEADJUST) value-added product (VAP) creates a file that includes all fields from original Atmospheric Radiation Measurement Climate Research Facility (ARM Facility) radiosonde files and contains several value-added fields that provide adjustments related to well-known humidity issues. SONDEADJUST produces data that correct documented biases in radiosonde humidity measurements. Previous efforts towards applying some of these corrections are available via the discontinued PI product sgpsondecorr1miloC1. Unique fields contained within this datastream include smoothed original relative humidity, dry bias corrected relative humidity, and final corrected relative humidity. The smoothed RH field refines the relative humidity from integers-the resolution of the instrument-to fractions of a percent. This profile is then used to calculate the dry bias corrected field. The final correction fixes the time-lag problem and uses the dry-bias field as input into the algorithm. In addition to dry bias, solar heating is another correction that is encompassed in the final corrected RH field. Output from SONDEADJUST differs from the previous RH-corrected datastreams in important ways. First, all three types of ARM radiosondes-Vaisala RS-80, RS-90, and RS-92-are corrected using dedicated procedures and/or parameters. Second, the output variables include all of those found in the original radiosonde file: dry bulb temperature, dewpoint temperature, wind speed, wind direction, eastward wind component, northward wind component, wind status (a Vaisala-produced field used in conjunction with the Loran system), ascent rate, and original relative humidity. Additional humidity fields are smoothed relative humidity, dry biased corrected relative humidity, final ambient relative humidity, and scaled adjusted relative humidity. Third, quality control (QC) flags of the fields from the original radiosonde datastream are brought into the SONDEADJUST output file. Additional QC variables are created for the new fields.

  9. Geothermal: Related Links

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Related Links Geothermal Technologies Legacy Collection HelpFAQ | Site Map | Contact Us HomeBasic Search About Publications Advanced Search New Hot Docs News Related Links...

  10. High temperature interfacial superconductivity

    DOE Patents [OSTI]

    Bozovic, Ivan (Mount Sinai, NY); Logvenov, Gennady (Port Jefferson Station, NY); Gozar, Adrian Mihai (Port Jefferson, NY)

    2012-06-19T23:59:59.000Z

    High-temperature superconductivity confined to nanometer-scale interfaces has been a long standing goal because of potential applications in electronic devices. The spontaneous formation of a superconducting interface in bilayers consisting of an insulator (La.sub.2CuO.sub.4) and a metal (La.sub.1-xSr.sub.xCuO.sub.4), neither of which is superconducting per se, is described. Depending upon the layering sequence of the bilayers, T.sub.c may be either .about.15 K or .about.30 K. This highly robust phenomenon is confined to within 2-3 nm around the interface. After exposing the bilayer to ozone, T.sub.c exceeds 50 K and this enhanced superconductivity is also shown to originate from a 1 to 2 unit cell thick interfacial layer. The results demonstrate that engineering artificial heterostructures provides a novel, unconventional way to fabricate stable, quasi two-dimensional high T.sub.c phases and to significantly enhance superconducting properties in other superconductors. The superconducting interface may be implemented, for example, in SIS tunnel junctions or a SuFET.

  11. High-Temperature Viscosity of Commercial Glasses

    SciTech Connect (OSTI)

    Hrma, Pavel R.

    2006-08-31T23:59:59.000Z

    Arrhenius models were developed for glass viscosity within the processing temperature of six types of commercial glasses: low-expansion-borosilicate glasses, E glasses, fiberglass wool glasses, TV panel glasses, container glasses, and float glasses. Both local models (for each of the six glass types) and a global model (for the composition region of commercial glasses, i.e., the six glass types taken together) are presented. The models are based on viscosity data previously obtained with rotating spindle viscometers within the temperature range between 900 C and 1550 C; the viscosity varied from 1 Pa?s to 750 Pa?s. First-order models were applied to relate Arrhenius coefficients to the mass fractions of 15 components: SiO2, TiO2, ZrO2, Al2O3, Fe2O3, B2O3, MgO, CaO, SrO, BaO, PbO, ZnO, Li2O, Na2O, K2O. The R2 is 0.98 for the global model and ranges from .097 to 0.99 for the six local models. The models are recommended for glasses containing 42 to 84 mass% SiO2 to estimate viscosities or temperatures at a constant viscosity for melts within both the temperature range from 1100 C to 1550 C and viscosity range from 5 to 400 Pa?s.

  12. Measurement of thermodynamic temperature of high temperature fixed points

    SciTech Connect (OSTI)

    Gavrilov, V. R.; Khlevnoy, B. B.; Otryaskin, D. A.; Grigorieva, I. A.; Samoylov, M. L.; Sapritsky, V. I. [All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), 46 Ozernaya St., Moscow 119361 (Russian Federation)] [All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), 46 Ozernaya St., Moscow 119361 (Russian Federation)

    2013-09-11T23:59:59.000Z

    The paper is devoted to VNIIOFI's measurements of thermodynamic temperature of the high temperature fixed points Co-C, Pt-C and Re-C within the scope of the international project coordinated by the Consultative Committee for Thermometry working group 5 'Radiation Thermometry'. The melting temperatures of the fixed points were measured by a radiance mode radiation thermometer calibrated against a filter radiometer with known irradiance spectral responsivity via a high temperature black body. This paper describes the facility used for the measurements, the results and estimated uncertainties.

  13. Breakdown of time-temperature superposition in a bead-spring polymer melt near the glass transition temperature

    E-Print Network [OSTI]

    Tamio Yamazaki

    2014-10-06T23:59:59.000Z

    The breakdown of the time-temperature superposition (TTS) near its glass transition temperature (Tg) in simple bead-spring polymer melts with and without the chain angle potential was numerically investigated. The stress relaxation modulus at different temperatures G(t,T) was calculated by the Green-Kubo relation. The TTS of G(t,T) of bead-spring polymer melts worked well at temperatures sufficiently higher than its Tg. However, when the system temperature is approaching the glass transition regime, the breakdown of TTS is observed. At temperatures near the Tg, the temperature dependence of the shift factor aTB, which is defined at the time scale between the bond relaxation and the chain relaxation regimes of a G(t)-function, is significantly stronger than ones aTA defined by the time scale of the chain relaxation modes. In direct relation to the breakdown of TTS of G(t,T), the decoupling of Stokes-Einstein law of diffusion-viscosity relation also appears in the glass transition regime. The analysis of the van Hove function Gs(r,t) and non-gaussian parameter, a2(t), of the bead motions strongly suggest that the TTS breakdown is concerned with the dynamic heterogeneity. The effect of the chain stiffness on the temperature dependence of the shift factors was also investigated in this study. The stiffer chains melt has a stronger temperature dependence of the shift factors than the ones of the flexible chains melt. However, regardless of the chain stiffness, the stress relaxation modulus functions of the bead-spring polymer melts will begin to breakdown the TTS at a similar Tg-normalized temperature around T/Tg ~ 1.2.

  14. IEEE BCTM5.1 Dependenceof ThermalResistanceon Ambientand Actual Temperature

    E-Print Network [OSTI]

    Technische Universiteit Delft

    resistance is inversely proportional to the thermal conductivity. This means that the temperature behaviour of the thermal resistance as function of power dissipation at constant ambient, but increasing device temperature increases the thermal resistance. The relation between temperature and power dissipation is then no longer

  15. Model Based Sensor System for Temperature Measurement in R744 Air Conditioning Systems

    E-Print Network [OSTI]

    Reitz, Sven; Schneider, Peter

    2008-01-01T23:59:59.000Z

    The goal is the development of a novel principle for the temperature acquisition of refrigerants in CO2 air conditioning systems. The new approach is based on measuring the temperature inside a pressure sensor, which is also needed in the system. On the basis of simulative investigations of different mounting conditions functional relations between measured and medium temperature will be derived.

  16. High-temperature ceramic receivers

    SciTech Connect (OSTI)

    Jarvinen, P. O.

    1980-01-01T23:59:59.000Z

    An advanced ceramic dome cavity receiver is discussed which heats pressurized gas to temperatures above 1800/sup 0/F (1000/sup 0/C) for use in solar Brayton power systems of the dispersed receiver/dish or central receiver type. Optical, heat transfer, structural, and ceramic material design aspects of the receiver are reported and the development and experimental demonstration of a high-temperature seal between the pressurized gas and the high-temperature silicon carbide dome material is described.

  17. RECHARGEABLE HIGH-TEMPERATURE BATTERIES

    E-Print Network [OSTI]

    Cairns, Elton J.

    2014-01-01T23:59:59.000Z

    F. Eshman, High-Performance Batteries for Electric-VehicleS. Sudar, High Performance Batteries for Electric-VehicleHIGH-TEMPERATURE BATTERIES Elton J. Cairns January 1981 TWO-

  18. Hotline IV ?High Temperature ESP

    Broader source: Energy.gov (indexed) [DOE]

    Hotline IV - High Temperature ESP Brindesh Dhruva (principal Inv.) Michael Dowling (presenter) Schlumberger Track Name May 18, 2010 This presentation does not contain any...

  19. Low Temperature Material Bonding Technique

    DOE Patents [OSTI]

    Ramsey, J. Michael (Knoxville, TN); Foote, Robert S. (Oak Ridge, TN)

    2000-10-10T23:59:59.000Z

    A method of performing a lower temperature bonding technique to bond together two mating pieces of glass includes applying a sodium silicate aqueous solution between the two pieces.

  20. Low temperature material bonding technique

    DOE Patents [OSTI]

    Ramsey, J. Michael (Knoxville, TN); Foote, Robert S. (Oak Ridge, TN)

    2002-02-12T23:59:59.000Z

    A method of performing a lower temperature bonding technique to bond together two mating pieces of glass includes applying a sodium silicate aqueous solution between the two pieces.

  1. Statistics of particle time-temperature histories.

    SciTech Connect (OSTI)

    Hewson, John C.; Lignell, David O.; Sun, Guangyuan

    2014-10-01T23:59:59.000Z

    Particles in non - isothermal turbulent flow are subject to a stochastic environment tha t produces a distribution of particle time - temperature histories. This distribution is a function of the dispersion of the non - isothermal (continuous) gas phase and the distribution of particles relative to that gas phase. In this work we extend the one - dimensional turbulence (ODT) model to predict the joint dispersion of a dispersed particle phase and a continuous phase. The ODT model predicts the turbulent evolution of continuous scalar fields with a model for the cascade of fluctuations to smaller sc ales (the 'triplet map') at a rate that is a function of the fully resolved one - dimens ional velocity field . Stochastic triplet maps also drive Lagrangian particle dispersion with finite Stokes number s including inertial and eddy trajectory - crossing effect s included. Two distinct approaches to this coupling between triplet maps and particle dispersion are developed and implemented along with a hybrid approach. An 'instantaneous' particle displacement model matches the tracer particle limit and provide s an accurate description of particle dispersion. A 'continuous' particle displacement m odel translates triplet maps into a continuous velocity field to which particles respond. Particles can alter the turbulence, and modifications to the stochastic rate expr ession are developed for two - way coupling between particles and the continuous phase. Each aspect of model development is evaluated in canonical flows (homogeneous turbulence, free - shear flows and wall - bounded flows) for which quality measurements are ava ilable. ODT simulations of non - isothermal flows provide statistics for particle heating. These simulations show the significance of accurately predicting the joint statistics of particle and fluid dispersion . Inhomogeneous turbulence coupled with the in fluence of the mean flow fields on particles of varying properties alter s particle dispersion. The joint particle - temperature dispersion leads to a distribution of temperature histories predicted by the ODT . Predictions are shown for the lower moments an d the full distributions of the particle positions, particle - observed gas temperatures and particle temperatures. An analysis of the time scales affecting particle - temperature interactions covers Lagrangian integral time scales based on temperature autoco rrelations, rates of temperature change associated with particle motion relative to the temperature field and rates of diffusional change of temperatures. These latter two time scales have not been investigated previously; they are shown to be strongly in termittent having peaked distributions with long tails. The logarithm of the absolute value of these time scales exhibits a distribution closer to normal. A cknowledgements This work is supported by the Defense Threat Reduction Agency (DTRA) under their Counter - Weapons of Mass Destruction Basic Research Program in the area of Chemical and Biological Agent Defeat under award number HDTRA1 - 11 - 4503I to Sandia National Laboratories. The authors would like to express their appreciation for the guidance provi ded by Dr. Suhithi Peiris to this project and to the Science to Defeat Weapons of Mass Destruction program.

  2. Temperature limited heater utilizing non-ferromagnetic conductor

    DOE Patents [OSTI]

    Vinegar; Harold J. (Bellaire, TX), Harris; Christopher Kelvin (Houston, TX)

    2012-07-17T23:59:59.000Z

    A heater is described. The heater includes a ferromagnetic conductor and an electrical conductor electrically coupled to the ferromagnetic conductor. The ferromagnetic conductor is positioned relative to the electrical conductor such that an electromagnetic field produced by time-varying current flow in the ferromagnetic conductor confines a majority of the flow of the electrical current to the electrical conductor at temperatures below or near a selected temperature.

  3. An experimental investigation of high temperature, high pressure paper drying

    E-Print Network [OSTI]

    Patel, Kamal Raoji

    1994-01-01T23:59:59.000Z

    % moisture removed oven dried mass of handsheet, g mass of handsheet after drying test, g mass of handsheet before drying test, g relative moisture removed from handsheet moisture removed by drying, % initial moisture (im) initial handsheet sample mass..., and the effects on the paper sheet and drying felt can be detrimental. Elevated temperatures reduce water viscosity which permits reduced resistance to water flow in the sheet. Pressing with a drying temperature of 95 C gives increased drying capacity, reduced...

  4. High temperature solar selective coatings

    DOE Patents [OSTI]

    Kennedy, Cheryl E

    2014-11-25T23:59:59.000Z

    Improved solar collectors (40) comprising glass tubing (42) attached to bellows (44) by airtight seals (56) enclose solar absorber tubes (50) inside an annular evacuated space (54. The exterior surfaces of the solar absorber tubes (50) are coated with improved solar selective coatings {48} which provide higher absorbance, lower emittance and resistance to atmospheric oxidation at elevated temperatures. The coatings are multilayered structures comprising solar absorbent layers (26) applied to the meta surface of the absorber tubes (50), typically stainless steel, topped with antireflective Savers (28) comprising at least two layers 30, 32) of refractory metal or metalloid oxides (such as titania and silica) with substantially differing indices of refraction in adjacent layers. Optionally, at least one layer of a noble metal such as platinum can be included between some of the layers. The absorbent layers cars include cermet materials comprising particles of metal compounds is a matrix, which can contain oxides of refractory metals or metalloids such as silicon. Reflective layers within the coating layers can comprise refractory metal silicides and related compounds characterized by the formulas TiSi. Ti.sub.3SiC.sub.2, TiAlSi, TiAN and similar compounds for Zr and Hf. The titania can be characterized by the formulas TiO.sub.2, Ti.sub.3O.sub.5. TiOx or TiO.sub.xN.sub.1-x with x 0 to 1. The silica can be at least one of SiO.sub.2, SiO.sub.2x or SiO.sub.2xN.sub.1-x with x=0 to 1.

  5. Breakdown of Stokes-Einstein relation in supercooled water

    E-Print Network [OSTI]

    Pradeep Kumar

    2007-02-06T23:59:59.000Z

    Water displays breakdown of the Stokes-Einstein relation at low temperatures. We hypothesize that the breakdown is a result of the structural changes and a sharp rise in dynamic heterogeneities that occurs low T upon crossing the Widom line.

  6. Goldberger-Treiman relation, [ital g][sub [ital A

    SciTech Connect (OSTI)

    Eletsky, V.L. (Institute for Theoretical Physics, University of California, Santa Barbara, California 93106 (United States) Institute for Theoretical Physics, Berne University, Sidlerstrasse 5, CH-3012 Berne (Switzerland)); Kogan, I.I. (Physics Department, Jadwin Hall, Princeton University, Princeton, New Jersey 08540 (United States))

    1994-04-01T23:59:59.000Z

    The Goldberger-Treiman relation is shown to persist in the chiral limit at finite temperatures to [ital O]([ital T][sup 2]). The [ital T] dependence of [ital g][sub [ital A

  7. The influence of temperature on egg composition in the grey partridge Perdix perdix

    E-Print Network [OSTI]

    Cucco, Marco

    , albumen, shell and total egg mass. Moreover, we examined the influence of temperature on three important related to shell mass. Yolk mass was positively related to temperature in the day farthest from laying, with yolk deposition preceding albumen and shell formation. Carotenoids and lysozyme concentration did

  8. The Use of Conditioned Air for Maintaining Quality of Stored Sorghum Grain.

    E-Print Network [OSTI]

    Person, Nat K. Jr.; Sorenson, J. W. Jr.; McCune, W. E.; Hobgood, Price

    1967-01-01T23:59:59.000Z

    Christensen (5) found that moisture content, temperature and time are all intimately related to the growth of molds in stored grains. Thus, the higher the moisture and temperature, within the limits of growth of the fungi involved, the shorter the per... minimum relative humidity of 80 percent in bulk bins is required for continued growth of molds. A relative humidity of 80 percent corresponds to an equilibrium moisture content of about 15 percent, wet basis, for sorghum grain at 70" F. (8). Insect...

  9. Low exhaust temperature electrically heated particulate matter filter system

    DOE Patents [OSTI]

    Gonze, Eugene V. (Pinckney, MI); Paratore, Jr., Michael J. (Howell, MI); Bhatia, Garima (Bangalore, IN)

    2012-02-14T23:59:59.000Z

    A system includes a particulate matter (PM) filter, a sensor, a heating element, and a control module. The PM filter includes with an upstream end that receives exhaust gas, a downstream end and multiple zones. The sensor detects a temperature of the exhaust gas. The control module controls current to the heating element to convection heat one of the zones and initiate a regeneration process. The control module selectively increases current to the heating element relative to a reference regeneration current level when the temperature is less than a predetermined temperature.

  10. Evaluation of building and occupant response to temperature and humidity: non-traditional heat stress considerations A comparison of different construction types used by the Texas Department of Criminal Justice

    E-Print Network [OSTI]

    Nalbone, Joseph Torey

    2005-02-17T23:59:59.000Z

    stifling hot in the summer and damp cold in the winter. The design and construction of dedicated prison facilities continued to progress slowly, but is was not until the 18th century and a review of world prisons by John Howard (State of the Prisons... at Dallas Chair of Advisory Committee: Dr. James C. Rock This study examined the effects of construction types on the indoor environment of selected prison facilities in the State of Texas. Three collocated facilities of the Texas Department...

  11. Mean ZZ Ceti pulsation period gauges stellar temperature

    E-Print Network [OSTI]

    Anjum S. Mukadam; M. H. Montgomery; A. Kim; D. E. Winget; S. O. Kepler; J. C. Clemens

    2006-12-15T23:59:59.000Z

    The mean pulsation period of ZZ Ceti stars increases with decreasing effective temperature as we traverse from the blue to the red edge of the instability strip. This well-established correlation between the mean period and spectroscopic temperature suggests that the mean period could be utilized as a tool to measure the relative temperature of the star independent of spectroscopy. Measuring the pulsation periods of a ZZ Ceti star is a simple, model-independent, and straight forward process as opposed to a spectroscopic determination of its temperature. Internal uncertainties in determining the spectroscopic temperature of a ZZ Ceti star are at least 200K, 15% of the 1350K width of the instability strip. The uncertainties in determining the mean period arise mostly from amplitude modulation in the pulsation spectrum and are smaller than 100s for 91% of the ZZ Ceti stars, temperature indicator rather than conventional spectroscopy. Presently we only claim that the relative temperatures of ZZ Ceti stars derived by using the mean pulsation period are certainly as good as and perhaps about 15% better than spectroscopy.

  12. Low temperature irradiation tests on

    E-Print Network [OSTI]

    McDonald, Kirk

    Sample cool down by He gas loop 10K ­ 20K Fast neutron flux Measured by Ni activation in 2010 1.4xK #12;reactor Cryogenics #12;Al-Cu-Mg He gas temperature near sample 12K Resistance changesLow temperature irradiation tests on stabilizer materials using reactor neutrons at KUR Makoto

  13. Impact Strength of High Relative Density Solid State CO, Blown CPET Microcellular Foams Impact Strength of High Relative Density

    E-Print Network [OSTI]

    Kumar, Vipin

    is an increased glass transition temperature (T,), thus requiring higher foaming temperatures. Baldwin and SuhImpact Strength of High Relative Density Solid State CO, Blown CPET Microcellular Foams ImpactTerephthalate) Microcellular Foams Vipin KurnaW, Richard P Juntunena, and Chris Barlowb University of Washington, Seattle

  14. Detecting temperature fluctuations at equilibrium

    E-Print Network [OSTI]

    Dixit, Purushottam D

    2015-01-01T23:59:59.000Z

    Gibbs and Boltzmann definitions of temperature agree only in the macroscopic limit. The ambiguity in identifying the equilibrium temperature of a finite sized `small' system exchanging energy with a bath is usually understood as a limitation of conventional statistical mechanics. We interpret this ambiguity as resulting from a stochastically fluctuating temperature coupled with the phase space variables giving rise to a broad temperature distribution. With this ansatz, we develop the equilibrium statistics and dynamics of small systems. Numerical evidence using an analytically tractable model shows that the effects of temperature fluctuations can be detected in equilibrium and dynamical properties of the phase space of the small system. Our theory generalizes statistical mechanics to small systems relevant to biophysics and nanotechnology.

  15. Research Initiative Will Demonstrate Low Temperature Geothermal...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Research Initiative Will Demonstrate Low Temperature Geothermal Electrical Power Generation Systems Using Oilfield Fluids Research Initiative Will Demonstrate Low Temperature...

  16. An investigation of the heat and mass transfer by free convection from humid air to a horizontal metal plate under frosting conditions

    E-Print Network [OSTI]

    Bell, Bobby

    1967-01-01T23:59:59.000Z

    . The frost on the top appeared to be fluffy while on the bottom it appeared to look like evenly positioned sta1act tes for slate temperatures of -50 F or less. Also, for temperatures of -50 F or less, the frost on the bottom side fell off at a small rate...

  17. Bulk viscosity of QCD matter near the critical temperature

    E-Print Network [OSTI]

    D. Kharzeev; K. Tuchin

    2007-05-29T23:59:59.000Z

    Kubo's formula relates bulk viscosity to the retarded Green's function of the trace of the energy-momentum tensor. Using low energy theorems of QCD for the latter we derive the formula which relates the bulk viscosity to the energy density and pressure of hot matter. We then employ the available lattice QCD data to extract the bulk viscosity as a function of temperature. We find that close to the deconfinement temperature bulk viscosity becomes large, with viscosity-to-entropy ratio zeta/s about 1.

  18. Effect of Gas Turbine Exhaust Temperature, Stack Temperature and Ambient Temperature on Overall Efficiency of Combine Cycle Power Plant

    E-Print Network [OSTI]

    unknown authors

    Abstract—The gas turbine exhaust temperature, stack temperature and ambient temperature play a very important role during the predication of the performance of combine cycle power plant. This paper covers parametric analysis of effects of gas turbine exhaust temperature, stack temperature and ambient temperature on the overall efficiency of combine cycle power plant keeping the gas turbine efficiency as well as steam turbine efficiency constant. The results shows that out of three variables i.e. turbine exhaust temperature, stack temperature and ambient temperature, the most dominating factor of increasing the overall efficiency of the combine cycle power plant is the stack temperature.

  19. Emergency building temperature restrictions. Final evaluation

    SciTech Connect (OSTI)

    None

    1980-11-01T23:59:59.000Z

    On July 5, 1979, DOE promulgated final regulations of the Emergency Building Temperature Restrictions program, placing emergency restrictions on thermostat settings for space heating, space cooling, and hot water in commercial, industrial, and nonresidential public buildings. The final regulations restricted space heating to a maximum of 65/sup 0/F, hot water temperature to a maximum of 105/sup 0/F, and cooling temperature to a minimum of 78/sup 0/F. A comprehensive evaluation of the entire EBTF program for a nine-month period from July 16, 1979 is presented. In Chapter 1, an estimate of the population of buildings covered by EBTR is presented. In Chapter 2, EBTR compliance by building type and region is reported. Exemptions are also discussed. In Chapter 3, the simulations of building energy use are explained and the relative impact of various building characteristics and effectiveness of different control strategies are estimated. Finally, in Chapter 4, the methodology for scaling the individual building energy savings to the national level is described, and estimated national energy savings are presented.

  20. High-Temperature Viscosity Of Commercial Glasses

    SciTech Connect (OSTI)

    Hrma, Pavel R.; See, Clem A.; Lam, Oanh P.; Minister, Kevin B.

    2005-01-01T23:59:59.000Z

    Viscosity was measured for six types of commercial glasses: low-expansion-borosilicate glasses, E glasses, fiberglass wool glasses, TV panel glasses, container glasses, and float glasses. Viscosity data were obtained with rotating spindle viscometers within the temperature range between 900°C and 1550°C; the viscosity varied from 1 Pa?s to 750 Pa?s. Arrhenius coefficients were calculated for individual glasses and linear models were applied to relate them to the mass fractions of 11 major components (SiO2, CaO, Na2O, Al2O3, B2O3, BaO, SrO, K2O, MgO, PbO, and ZrO2) and 12 minor components (Fe2O3, ZnO, Li2O, TiO2, CeO2, F, Sb2O3, Cr2O3, As2O3, MnO2, SO3, and Co3O4). The models are recommended for glasses containing 42 to 84 mass% SiO2 to estimate viscosities or temperatures at a constant viscosity for melts within both the temperature range from 1100°C to 1550°C and viscosity range from 10 to 400 Pa?s.

  1. Shock temperature measurements in ammonia

    SciTech Connect (OSTI)

    Radousky, H.B.; Mitchell, A.C.; Nellis, W.J.; Ross, M.

    1985-07-01T23:59:59.000Z

    Our first shock temperature measurements on a cryogenic target are reported for NH/sub 3/. A new fast optical pyrometer and a cryogenic specimen holder for liquid NH/sub 3/ were developed to measure shock temperatures of 4400 and 3600 K at pressures of 61 and 48 GPa. These conditions correspond to those in the ice layers in Uranus and Neptune. The shock temperature data are in reasonable agreement with an equation of state based on an intermolecular potential derived from NH/sub 3/ Hugoniot data.

  2. INNOVATIVE INSTRUMENTATION AND ANALYSIS OF THE TEMPERATURE MEASUREMENT FOR HIGH TEMPERATURE GASIFICATION

    SciTech Connect (OSTI)

    Seong W. Lee

    2004-10-01T23:59:59.000Z

    The systematic tests of the gasifier simulator on the clean thermocouple were completed in this reporting period. Within the systematic tests on the clean thermocouple, five (5) factors were considered as the experimental parameters including air flow rate, water flow rate, fine dust particle amount, ammonia addition and high/low frequency device (electric motor). The fractional factorial design method was used in the experiment design with sixteen (16) data sets of readings. Analysis of Variances (ANOVA) was applied to the results from systematic tests. The ANOVA results show that the un-balanced motor vibration frequency did not have the significant impact on the temperature changes in the gasifier simulator. For the fine dust particles testing, the amount of fine dust particles has significant impact to the temperature measurements in the gasifier simulator. The effects of the air and water on the temperature measurements show the same results as reported in the previous report. The ammonia concentration was included as an experimental parameter for the reducing environment in this reporting period. The ammonia concentration does not seem to be a significant factor on the temperature changes. The linear regression analysis was applied to the temperature reading with five (5) factors. The accuracy of the linear regression is relatively low, which is less than 10% accuracy. Nonlinear regression was also conducted to the temperature reading with the same factors. Since the experiments were designed in two (2) levels, the nonlinear regression is not very effective with the dataset (16 readings). An extra central point test was conducted. With the data of the center point testing, the accuracy of the nonlinear regression is much better than the linear regression.

  3. Modeling the Effect of Curing on Early Age Distress Potential of Concrete Pavement

    E-Print Network [OSTI]

    Bari, Muhammad Ehsanul

    2014-04-11T23:59:59.000Z

    , such as the variation of temperature and relative humidity, during the early age after concrete placement. Experimental test results were obtained and mathematical models were developed for this research. Modeling the effect of curing process in response...

  4. F. G. WALTON SMITH PRINCIPAL CHARACTERISTICS

    E-Print Network [OSTI]

    Miami, University of

    in Panama City, Florida, the catamaran boasts twin Cummins engines at 760 hp each, Servogear variable pitch and direction, air temperature, relative humidity, barometric pressure, and solar radiation; -Over

  5. CX-003342: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    High Temperature, Low Relative Humidity Polymer-Type MembranesCX(s) Applied: A9, B3.6Date: 08/13/2010Location(s): ArizonaOffice(s): Energy Efficiency and Renewable Energy, Golden Field Office

  6. Evaluation of Alternative Cooking and Cooling Procedures for Large, Intact Meat Products to Achieve Lethality and Stabilization Microbiological Performance Standards

    E-Print Network [OSTI]

    Haneklaus, Ashley

    2010-01-16T23:59:59.000Z

    ) and smokehouse relative humidities (50% or 90%). Phase 2 investigated the effect of alternative stabilization parameters on log growth of Clostridium perfringens. Stabilization treatments extended the times taken to reduce internal product temperature from 54.4...

  7. Optimizing Low Temperature Diesel Combustion

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Diesel Consortium 2008 DOE Merit Review - UW-ERC 1 Optimizing Low Temperature Diesel Combustion Profs. Rolf Reitz, P. Farrell, D. Foster, J. Ghandhi, C. Rutland, S. Sanders Engine...

  8. High temperature structural insulating material

    DOE Patents [OSTI]

    Chen, W.Y.

    1984-07-27T23:59:59.000Z

    A high temperature structural insulating material useful as a liner for cylinders of high temperature engines through the favorable combination of high service temperature (above about 800/sup 0/C), low thermal conductivity (below about 0.2 W/m/sup 0/C), and high compressive strength (above about 250 psi). The insulating material is produced by selecting hollow ceramic beads with a softening temperature above about 800/sup 0/C, a diameter within the range of 20-200 ..mu..m, and a wall thickness in the range of about 2 to 4 ..mu..m; compacting the beads and a compatible silicate binder composition under pressure and sintering conditions to provide the desired structural form with the structure having a closed-cell, compact array of bonded beads.

  9. High temperature structural insulating material

    DOE Patents [OSTI]

    Chen, Wayne Y. (Munster, IN)

    1987-01-01T23:59:59.000Z

    A high temperature structural insulating material useful as a liner for cylinders of high temperature engines through the favorable combination of high service temperature (above about 800.degree. C.), low thermal conductivity (below about 0.2 W/m.degree. C.), and high compressive strength (above about 250 psi). The insulating material is produced by selecting hollow ceramic beads with a softening temperature above about 800.degree. C., a diameter within the range of 20-200 .mu.m, and a wall thickness in the range of about 2-4 .mu.m; compacting the beads and a compatible silicate binder composition under pressure and sintering conditions to provide the desired structural form with the structure having a closed-cell, compact array of bonded beads.

  10. LOW TEMPERATURE CATHODE SUPPORTED ELECTROLYTES

    SciTech Connect (OSTI)

    Harlan U. Anderson; Fatih Dogan; Vladimir Petrovsky

    2002-03-31T23:59:59.000Z

    This project has three main goals: Thin Films Studies, Preparation of Graded Porous Substrates and Basic Electrical Characterization and testing of Planar Single Cells. This period has continued to address the problem of making dense 1/2 to 5 {micro}m thick dense layers on porous substrates (the cathode LSM). Our current status is that we are making structures of 2-5 cm{sup 2} in area, which consist of either dense YSZ or CGO infiltrated into a 2-5 {micro}m thick 50% porous layer made of either nanoncrystalline CGO or YSZ powder. This composite structure coats a macroporous cathode or anode; which serves as the structural element of the bi-layer structure. These structures are being tested as SOFC elements. A number of structures have been evaluated both as symmetrical and as button cell configuration. Results of this testing indicates that the cathodes contribute the most to cell losses for temperatures below 750 C. In this investigation different cathode materials were studied using impedance spectroscopy of symmetric cells and IV characteristics of anode supported fuel cells. Cathode materials studied included La{sub 0.8}Sr{sub 0.2}Co{sub 0.2}Fe{sub 0.8}O{sub 3} (LSCF), La{sub 0.7}Sr{sub 0.2}MnO{sub 3} (LSM), Pr{sub 0.8}Sr{sub 0.2}Fe{sub 0.8}O{sub 3} (PSCF), Sm{sub 0.8}Sr{sub 0.2}Co{sub 0.2}Fe{sub 0.8}O{sub 3} (SSCF), and Yb{sub .8}Sr{sub 0.2}Co{sub 0.2}Fe{sub 0.8}O{sub 3} (SSCF). A new technique for filtering the Fourier transform of impedance data was used to increase the sensitivity of impedance analysis. By creating a filter specifically for impedance spectroscopy the resolution was increased. The filter was tailored to look for specific circuit elements like R//C, Warburg, or constant phase elements. As many as four peaks can be resolved using the filtering technique on symmetric cells. It may be possible to relate the different peaks to material parameters, like the oxygen exchange coefficient. The cathode grouped in order from lowest to highest ASR is LSCF < PSCF < SSCF < YSCF < LSM. The button cell results agree with this ordering indicating that this is an important tool for use in developing our understanding of electrode behavior in fuel cells.

  11. Fuel Temperature Coefficient of Reactivity

    SciTech Connect (OSTI)

    Loewe, W.E.

    2001-07-31T23:59:59.000Z

    A method for measuring the fuel temperature coefficient of reactivity in a heterogeneous nuclear reactor is presented. The method, which is used during normal operation, requires that calibrated control rods be oscillated in a special way at a high reactor power level. The value of the fuel temperature coefficient of reactivity is found from the measured flux responses to these oscillations. Application of the method in a Savannah River reactor charged with natural uranium is discussed.

  12. Low to moderate temperature nanolaminate heater

    DOE Patents [OSTI]

    Eckels, J. Del (Livermore, CA); Nunes, Peter J. (Danville, CA); Simpson, Randall L. (Livermore, CA); Hau-Riege, Stefan (Fremont, CA); Walton, Chris (Oakland, CA); Carter, J. Chance (Livermore, CA); Reynolds, John G. (San Ramon, CA)

    2011-01-11T23:59:59.000Z

    A low to moderate temperature heat source comprising a high temperature energy source modified to output low to moderate temperatures wherein the high temperature energy source modified to output low to moderate temperatures is positioned between two thin pieces to form a close contact sheath. In one embodiment the high temperature energy source modified to output low to moderate temperatures is a nanolaminate multilayer foil of reactive materials that produces a heating level of less than 200.degree. C.

  13. Relationalism vs. Bayesianism

    E-Print Network [OSTI]

    Thomas Marlow

    2006-03-07T23:59:59.000Z

    We compare and contrast the basic principles of two philosophies: Bayesianism and relationalism. These two philosophies are both based upon criteria of rationality. The analogy invoked in such a comparison seems rather apt when discussing tentative proofs of quantum nonlocality. We argue that Bayesianism is almost to quantum theory, what general covariance is to general relativity. This is because the Bayesian interpretation of quantum theory can be given a relational flavour.

  14. Community Relations Plan

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the Permittees and the public are documented during the Hazardous Waste Facility Permit Community Relations Plan development. Contact Environmental Communication & Public...

  15. Hydrogen Storage Related Links

    Broader source: Energy.gov [DOE]

    The following resources provide details about DOE-funded hydrogen storage activities, research plans and roadmaps, models and tools, and additional related links.

  16. Thermodynamics and scale relativity

    E-Print Network [OSTI]

    Robert Carroll

    2011-10-13T23:59:59.000Z

    It is shown how the fractal paths of scale relativity (following Nottale) can be introduced into a thermodynamical context (following Asadov-Kechkin).

  17. High temperature thermometric phosphors for use in a temperature sensor

    DOE Patents [OSTI]

    Allison, Stephen W. (Knoxville, TN); Cates, Michael R. (Oak Ridge, TN); Boatner, Lynn A. (Oak Ridge, TN); Gillies, George T. (Earlysville, VA)

    1998-01-01T23:59:59.000Z

    A high temperature phosphor consists essentially of a material having the general formula LuPO.sub.4 :Dy.sub.(x),Eu.sub.(y), wherein: 0.1 wt %.ltoreq.x.ltoreq.20 wt % and 0.1 wt %.ltoreq.y.ltoreq.20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopent. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions.

  18. High temperature thermometric phosphors for use in a temperature sensor

    DOE Patents [OSTI]

    Allison, S.W.; Cates, M.R.; Boatner, L.A.; Gillies, G.T.

    1998-03-24T23:59:59.000Z

    A high temperature phosphor consists essentially of a material having the general formula LuPO{sub 4}:Dy{sub (x)},Eu{sub (y)}, wherein: 0.1 wt %{<=}x{<=}20 wt % and 0.1 wt %{<=}y{<=}20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopant. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions. 2 figs.

  19. PHOTOSYNTHESIS AND RELATED PROCESSES

    E-Print Network [OSTI]

    Govindjee

    #12;#12;#12;#12;PHOTOSYNTHESIS AND RELATED PROCESSES VOLUME II Part 2 #12;« '«;- py as- b^ Section Research, 7, 288, 1954). #12;PHOTOSYNTHESIS nnd Related Processes By EUGENE I. RABINOWITCH Research Professor, Photosynthesis Research Labora- tory, Department of Botany, University of Illinois. Formerly

  20. Finite temperature topological order in 2D topological color codes

    E-Print Network [OSTI]

    Mehdi Kargarian

    2009-07-19T23:59:59.000Z

    In this work the topological order at finite temperature in two-dimensional color code is studied. The topological entropy is used to measure the behavior of the topological order. Topological order in color code arises from the colored string-net structures. By imposing the hard constrained limit the exact solution of the entanglement entropy becomes possible. For finite size systems, by raising the temperature, one type of string-net structure is thermalized and the associative topological entropy vanishes. In the thermodynamic limit the underlying topological order is fragile even at very low temperatures. Taking first the thermodynamic limit and then the zero-temperature limit and vice versa does not commute, and their difference is related only to the topology of regions. The contribution of the colors and symmetry of the model in the topological entropy is also discussed. It is shown how the gauge symmetry of the color code underlies the topological entropy.

  1. Chiral dynamics in the low-temperature phase of QCD

    E-Print Network [OSTI]

    Bastian B. Brandt; Anthony Francis; Harvey B. Meyer; Daniel Robaina

    2014-10-22T23:59:59.000Z

    We investigate the low-temperature phase of QCD and the crossover region with two light flavors of quarks. The chiral expansion around the point $(T, m_q = 0)$ in the temperature vs. quark-mass plane indicates that a sharp real-time excitation exists with the quantum numbers of the pion. We determine its dispersion relation and test the applicability of the chiral expansion. The time-dependent correlators are also analyzed using the Maximum Entropy Method (MEM), yielding consistent results. Finally, we test the predictions of ordinary chiral perturbation theory around the point $(T = 0, m_q = 0)$ for the temperature dependence of static observables. Around the crossover temperature, we find that all quantities considered depend only mildly on the quark mass in the considered range 8MeV $\\leq \\bar{m}^{\\bar{\\text{MS}}} \\leq$ 15MeV.

  2. A 3-dimensional hyperbolic Stefan problem with discontinuous temperature

    SciTech Connect (OSTI)

    Li, Dening (West Virginia University, Morgantown (United States))

    1991-09-01T23:59:59.000Z

    The hyperbolic heat transfer model is obtained by replacing the classical Fourier's law with a relaxation relation. The conditions are derived for the local existence and uniqueness of classical solutions for a 3D Stefan problem of a hyperbolic heat-transfer model where the temperature can sustain a jump across the phase-change interface. 15 refs.

  3. New framework hydrous silicate K{sub 3}Sc[Si{sub 3}O{sub 9}] {center_dot} H{sub 2}O related to the high-temperature anhydrous silicate K{sub 3}Ho[Si{sub 3}O{sub 9}] and symmetry analysis of a phase transition with prediction of structures

    SciTech Connect (OSTI)

    Belokoneva, E. L., E-mail: elbel@geol.msu.ru; Zorina, A. P.; Dimitrova, O. V. [Moscow State University, Faculty of Geology (Russian Federation)

    2013-07-15T23:59:59.000Z

    Crystals of a new framework silicate K{sub 3}Sc[Si{sub 3}O{sub 9}] {center_dot} H{sub 2}O, space group Pm2{sub 1}n (nonstandard setting of space group Pmn2{sub 1} = C{sub 2v}{sup 7}), are obtained under hydrothermal conditions. The structure is determined without preliminary knowledge of the chemical formula. The absolute configuration is determined. The structure is close to that of the high-temperature K{sub 3}Ho[Si{sub 3}O{sub 9}] phase, which was obtained upon the heating of K{sub 3}HoSi{sub 3}O{sub 8}(OH){sub 2}. This structural similarity is due to the specific conditions of synthesis and an analogous formula, where holmium is replaced by scandium. A symmetry analysis shows that the high local symmetry of a block (rod) is responsible for the first-order phase transition of both the order-disorder (OD) and displacement type. The number of structures in which the simplest and high-symmetry layers are multiplied by different symmetry elements are predicted.

  4. Thermal disconnect for high-temperature batteries

    DOE Patents [OSTI]

    Jungst, Rudolph George (Albuquerque, NM); Armijo, James Rudolph (Albuquerque, NM); Frear, Darrel Richard (Austin, TX)

    2000-01-01T23:59:59.000Z

    A new type of high temperature thermal disconnect has been developed to protect electrical and mechanical equipment from damage caused by operation at extreme temperatures. These thermal disconnects allow continuous operation at temperatures ranging from 250.degree. C. to 450.degree. C., while rapidly terminating operation at temperatures 50.degree. C. to 150.degree. C. higher than the continuous operating temperature.

  5. Response of fish to different simulated rates of water temperature increase

    SciTech Connect (OSTI)

    Wike, L.D.; Tuckfield, R.C.

    1992-08-01T23:59:59.000Z

    We initiated this study to define the limits of effluent-temperature rate increases during reactor restart, which will help minimize fish kills. We constructed an apparatus for exposing fish to various temperature-increase regimens and conducted two experiments based on information from system tests and scoping runs. In the rate experiment, we acclimated the fish to 20{degree}C, and then raised the temperature to 40{degree}C at varying rates. Because scoping runs and literature suggested that acclimation temperature may affect temperature-related mortality, we conducted an acclimation experiment. We acclimated the fish to various temperatures, then raised the temperatures to 39--40{degree}C at a rate of 2{degree}C every 12 hours. Based on the analysis of the data, we recommend temperature-increase rates during reactor restart of 2.5{degree}C every nine hours if ambient water temperatures are over 20{degree}C. If water temperatures are at or below 20{degree}C, we recommend temperature-increase rates of 2.5{degree}C every 12 hours. No regulation of temperature is required after effluent temperatures reach 40{degree}C. We recommend further studies, including expanded testing with the simulation system and behavioral and bioenergetic investigations that may further refine acceptable rates of effluent-temperature increases.

  6. Using electrical resistance tomography to map subsurface temperatures

    DOE Patents [OSTI]

    Ramirez, Abelardo L. (Pleasanton, CA); Chesnut, Dwayne A. (San Francisco, CA); Daily, William D. (Livermore, CA)

    1994-01-01T23:59:59.000Z

    A method is provided for measuring subsurface soil or rock temperatures remotely using electrical resistivity tomography (ERT). Electrical resistivity measurements are made using electrodes implanted in boreholes driven into the soil and/or at the ground surface. The measurements are repeated as some process changes the temperatures of the soil mass/rock mass. Tomographs of electrical resistivity are calculated based on the measurements using Poisson's equation. Changes in the soil/rock resistivity can be related to changes in soil/rock temperatures when: (1) the electrical conductivity of the fluid trapped in the soil's pore space is low, (2) the soil/rock has a high cation exchange capacity and (3) the temperature changes are sufficiently high. When these three conditions exist the resistivity changes observed in the ERT tomographs can be directly attributed to changes in soil/rock temperatures. This method provides a way of mapping temperature changes in subsurface soils remotely. Distances over which the ERT method can be used to monitor changes in soil temperature range from tens to hundreds of meters from the electrode locations.

  7. Using electrical resistance tomography to map subsurface temperatures

    DOE Patents [OSTI]

    Ramirez, A.L.; Chesnut, D.A.; Daily, W.D.

    1994-09-13T23:59:59.000Z

    A method is provided for measuring subsurface soil or rock temperatures remotely using electrical resistivity tomography (ERT). Electrical resistivity measurements are made using electrodes implanted in boreholes driven into the soil and/or at the ground surface. The measurements are repeated as some process changes the temperatures of the soil mass/rock mass. Tomographs of electrical resistivity are calculated based on the measurements using Poisson's equation. Changes in the soil/rock resistivity can be related to changes in soil/rock temperatures when: (1) the electrical conductivity of the fluid trapped in the soil's pore space is low, (2) the soil/rock has a high cation exchange capacity and (3) the temperature changes are sufficiently high. When these three conditions exist the resistivity changes observed in the ERT tomographs can be directly attributed to changes in soil/rock temperatures. This method provides a way of mapping temperature changes in subsurface soils remotely. Distances over which the ERT method can be used to monitor changes in soil temperature range from tens to hundreds of meters from the electrode locations. 1 fig.

  8. Finite Temperature Closed Superstring Theory

    E-Print Network [OSTI]

    Shyamoli Chaudhuri

    2005-09-12T23:59:59.000Z

    We find that the gas of IIA strings undergoes a phase transition into a gas of IIB strings at the self-dual temperature. A gas of free heterotic strings undergoes a Kosterlitz-Thouless duality transition with positive free energy and positive specific heat but vanishing internal energy at criticality. We examine the consequences of requiring a tachyon-free thermal string spectrum. We show that in the absence of Ramond-Ramond fluxes the IIA and IIB string ensembles are thermodynamically ill-defined. The 10D heterotic superstrings have nonabelian gauge fields and in the presence of a temperature dependent Wilson line background are found to share a stable and tachyon-free ground state at all temperatures starting from zero with gauge group SO(16)xSO(16). The internal energy of the heterotic string is a monotonically increasing function of temperature with a stable and supersymmetric zero temperature limit. Our results point to the necessity of gauge fields in a viable weakly coupled superstring theory. Note Added (Sep 2005).

  9. High temperature Seebeck coefficient metrology

    SciTech Connect (OSTI)

    Martin, J. [Materials Science and Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Tritt, T. [Department of Physics and Astronomy, Clemson University, Clemson, South Carolina 29634 (United States); Uher, C. [Department of Physics, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2010-12-15T23:59:59.000Z

    We present an overview of the challenges and practices of thermoelectric metrology on bulk materials at high temperature (300 to 1300 K). The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential property measurement for evaluating the potential performance of novel thermoelectric materials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at high temperature. This has led to the implementation of nonideal practices that have further complicated the confirmation of reported high ZT materials. To ensure meaningful interlaboratory comparison of data, thermoelectric measurements must be reliable, accurate, and consistent. This article will summarize and compare the relevant measurement techniques and apparatus designs required to effectively manage uncertainty, while also providing a reference resource of previous advances in high temperature thermoelectric metrology.

  10. High temperature Seebeck coefficient metrology

    SciTech Connect (OSTI)

    Martin, J.; Tritt, T.; Uher, Ctirad

    2010-01-01T23:59:59.000Z

    We present an overview of the challenges and practices of thermoelectric metrology on bulk materials at high temperature (300 to 1300 K). The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential propertymeasurement for evaluating the potential performance of novel thermoelectricmaterials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at high temperature. This has led to the implementation of nonideal practices that have further complicated the confirmation of reported high ZT materials. To ensure meaningful interlaboratory comparison of data, thermoelectricmeasurements must be reliable, accurate, and consistent. This article will summarize and compare the relevant measurement techniques and apparatus designs required to effectively manage uncertainty, while also providing a reference resource of previous advances in high temperature thermoelectric metrology.

  11. Mechanical instability at finite temperature

    E-Print Network [OSTI]

    Xiaoming Mao; Anton Souslov; Carlos I. Mendoza; T. C. Lubensky

    2014-07-08T23:59:59.000Z

    Many physical systems including lattices near structural phase transitions, glasses, jammed solids, and bio-polymer gels have coordination numbers that place them at the edge of mechanical instability. Their properties are determined by an interplay between soft mechanical modes and thermal fluctuations. In this paper we investigate a simple square-lattice model with a $\\phi^4$ potential between next-nearest-neighbor sites whose quadratic coefficient $\\kappa$ can be tuned from positive negative. We show that its zero-temperature ground state for $\\kappa power-law behavior of the shear modulus as a function of temperature. We expect our study to provide a general framework for the study of finite-temperature mechanical and phase behavior of other systems with a large number of floppy modes.

  12. RFID tag antenna based temperature sensing

    E-Print Network [OSTI]

    Bhattacharyya, Rahul

    Temperature monitoring is important in a number of fields, particularly cold supply chain applications. Most commercial wireless temperature sensors consist of transceivers, memory and batteries to maintain a temperature ...

  13. Temperature dependence of the indentation size effect

    E-Print Network [OSTI]

    Franke, Oliver

    The influence of temperature on the indentation size effect is explored experimentally. Copper is indented on a custom-built high-temperature nanoindenter at temperatures between ambient and 200 °C, in an inert atmosphere ...

  14. Crystal face temperature determination means

    DOE Patents [OSTI]

    Nason, D.O.; Burger, A.

    1994-11-22T23:59:59.000Z

    An optically transparent furnace having a detection apparatus with a pedestal enclosed in an evacuated ampule for growing a crystal thereon is disclosed. Temperature differential is provided by a source heater, a base heater and a cold finger such that material migrates from a polycrystalline source material to grow the crystal. A quartz halogen lamp projects a collimated beam onto the crystal and a reflected beam is analyzed by a double monochromator and photomultiplier detection spectrometer and the detected peak position in the reflected energy spectrum of the reflected beam is interpreted to determine surface temperature of the crystal. 3 figs.

  15. High temperature superconductor current leads

    DOE Patents [OSTI]

    Hull, John R. (Hinsdale, IL); Poeppel, Roger B. (Glen Ellyn, IL)

    1995-01-01T23:59:59.000Z

    An electrical lead having one end for connection to an apparatus in a cryogenic environment and the other end for connection to an apparatus outside the cryogenic environment. The electrical lead includes a high temperature superconductor wire and an electrically conductive material distributed therein, where the conductive material is present at the one end of the lead at a concentration in the range of from 0 to about 3% by volume, and at the other end of the lead at a concentration of less than about 20% by volume. Various embodiments are shown for groups of high temperature superconductor wires and sheaths.

  16. Temperature Resistant Optimal Ratchet Transport

    E-Print Network [OSTI]

    Cesar Manchein; Alan Celestino; Marcus W Beims

    2012-11-12T23:59:59.000Z

    Stable periodic structures containing optimal ratchet transport, recently found in the parameter space dissipation versus ratchet parameter [PRL 106, 234101 (2011)], are shown to be resistant to reasonable temperatures, reinforcing the expectation that they are essential to explain the optimal ratchet transport in nature. Critical temperatures for their destruction, valid from the overdamping to close to the conservative limits, are obtained numerically and shown to be connected to the current efficiency, given here analytically. Results are demonstrated for a discrete ratchet model and generalized to the Langevin equation with an additional external oscillating force.

  17. High temperature superconductor current leads

    DOE Patents [OSTI]

    Hull, J.R.; Poeppel, R.B.

    1995-06-20T23:59:59.000Z

    An electrical lead is disclosed having one end for connection to an apparatus in a cryogenic environment and the other end for connection to an apparatus outside the cryogenic environment. The electrical lead includes a high temperature superconductor wire and an electrically conductive material distributed therein, where the conductive material is present at the one end of the lead at a concentration in the range of from 0 to about 3% by volume, and at the other end of the lead at a concentration of less than about 20% by volume. Various embodiments are shown for groups of high temperature superconductor wires and sheaths. 9 figs.

  18. Mass and heat transfer model of Tubular Solar Still

    SciTech Connect (OSTI)

    Ahsan, Amimul [University Putra Malaysia, Dept. Civil Engineering, Faculty of Engineering, 43400 UPM Serdang, Selangor (Malaysia); Fukuhara, Teruyuki [University of Fukui, Graduate School of Engineering, 3-9-1 Bunkyo, Fukui 910-8507 (Japan)

    2010-07-15T23:59:59.000Z

    In this paper, a new mass and heat transfer model of a Tubular Solar Still (TSS) was proposed incorporating various mass and heat transfer coefficients taking account of the humid air properties inside the still. The heat balance of the humid air and the mass balance of the water vapor in the humid air were formulized for the first time. As a result, the proposed model enabled to calculate the diurnal variations of the temperature, water vapor density and relative humidity of the humid air, and to predict the hourly condensation flux besides the temperatures of the water, cover and trough, and the hourly evaporation flux. The validity of the proposed model was verified using the field experimental results carried out in Fukui, Japan and Muscat, Oman in 2008. The diurnal variations of the calculated temperatures and water vapor densities had a good agreement with the observed ones. Furthermore, the proposed model can predict the daily and hourly production flux precisely. (author)

  19. Narrowband high temperature superconducting receiver for low frequency radio waves

    DOE Patents [OSTI]

    Reagor, David W. (Los Alamos, NM)

    2001-01-01T23:59:59.000Z

    An underground communicating device has a low-noise SQUID using high temperature superconductor components connected to detect a modulated external magnetic flux for outputting a voltage signal spectrum that is related to the varying magnetic flux. A narrow bandwidth filter may be used to select a portion of the voltage signal spectrum that is relatively free of power line noise to output a relatively low noise output signal when operating in a portion of the electromagnetic spectra where such power line noise exists. A demodulator outputs a communication signal, which may be an FM signal, indicative of a modulation on the modulated external magnetic flux.

  20. Relational Dynamic Bayesian Networks

    E-Print Network [OSTI]

    Domingos, P; Weld, D; 10.1613/jair.1625

    2011-01-01T23:59:59.000Z

    Stochastic processes that involve the creation of objects and relations over time are widespread, but relatively poorly studied. For example, accurate fault diagnosis in factory assembly processes requires inferring the probabilities of erroneous assembly operations, but doing this efficiently and accurately is difficult. Modeled as dynamic Bayesian networks, these processes have discrete variables with very large domains and extremely high dimensionality. In this paper, we introduce relational dynamic Bayesian networks (RDBNs), which are an extension of dynamic Bayesian networks (DBNs) to first-order logic. RDBNs are a generalization of dynamic probabilistic relational models (DPRMs), which we had proposed in our previous work to model dynamic uncertain domains. We first extend the Rao-Blackwellised particle filtering described in our earlier work to RDBNs. Next, we lift the assumptions associated with Rao-Blackwellization in RDBNs and propose two new forms of particle filtering. The first one uses abstracti...

  1. General relativity and experiment

    E-Print Network [OSTI]

    T. Damour

    1994-12-08T23:59:59.000Z

    The confrontation between Einstein's theory of gravitation and experiment is summarized. Although all current experimental data are compatible with general relativity, the importance of pursuing the quest for possible deviations from Einstein's theory is emphasized.

  2. Thermodynamic Advantages of Low Temperature Combustion Engines...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Advantages of Low Temperature Combustion Engines Including the Use of Low Heat Rejection Concepts Thermodynamic Advantages of Low Temperature Combustion Engines Including the Use...

  3. Acid Doped Membranes for High Temperature PEMFC

    Broader source: Energy.gov [DOE]

    Presentation on Acid Doped Membranes for High Temperature PEMFC to the High Temperature Membrane Working Group, May 25, 2004 in Philadelphia, PA.

  4. Variable Temperature UHV STM/AFM | EMSL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Temperature UHV STMAFM The Omicron variable temperature ultra-high vacuum (UHV) scanning tunneling microscope (VTSTM) is designed to study the structure of both clean and...

  5. High-Temperature Thermoelectric Materials Characterization for...

    Broader source: Energy.gov (indexed) [DOE]

    High-Temperature Thermoelectric Materials Characterization for Automotive Waste Heat Recovery: Success Stories from the High Temperature Materials Laboratory (HTML) User Program...

  6. High Temperature Thermoelectric Materials Characterization for...

    Broader source: Energy.gov (indexed) [DOE]

    High Temperature Thermoelectric Materials Characterization for Automotive Waste Heat Recovery: Success Stories from the High Temperature Materials Laboratory (HTML) User Program...

  7. Susanville District Heating District Heating Low Temperature...

    Open Energy Info (EERE)

    Susanville District Heating District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Susanville District Heating District Heating Low Temperature...

  8. Litchfield Correctional Center District Heating Low Temperature...

    Open Energy Info (EERE)

    Correctional Center District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Litchfield Correctional Center District Heating Low Temperature Geothermal...

  9. Temperature and cooling management in computing systems

    E-Print Network [OSTI]

    Ayoub, Raid

    2011-01-01T23:59:59.000Z

    Chapter 6 Conclusion and Future Work Temperature and coolingthan 1%. Future research directions Temperature and coolingcooling are critical aspects of design in today’s and future

  10. SPREADSHEET DESCRIPTION DOCUMENT FOR SATURATION TEMPERATURE CALCULATION

    SciTech Connect (OSTI)

    JO J

    2008-08-29T23:59:59.000Z

    This document describes the methodology for determining the saturation temperature in waste tanks. The saturation temperature is used to calculate neutral buoyancy ratio.

  11. Geothermal Food Processors Agricultural Drying Low Temperature...

    Open Energy Info (EERE)

    Food Processors Agricultural Drying Low Temperature Geothermal Facility Jump to: navigation, search Name Geothermal Food Processors Agricultural Drying Low Temperature Geothermal...

  12. Nanostructured High Temperature Bulk Thermoelectric Energy Conversion...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    High Temperature Bulk Thermoelectric Energy Conversion for Efficient Waste Heat Recovery Nanostructured High Temperature Bulk Thermoelectric Energy Conversion for Efficient Waste...

  13. Manufacturing Barriers to High Temperature PEM Commercialization...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Barriers to High Temperature PEM Commercialization Manufacturing Barriers to High Temperature PEM Commercialization Presented at the NREL Hydrogen and Fuel Cell Manufacturing R&D...

  14. Temperature Independent Physisorption Kinetics and Adsorbate...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Temperature Independent Physisorption Kinetics and Adsorbate Layer Compression for Ar Adsorbed on Pt (111). Temperature Independent Physisorption Kinetics and Adsorbate Layer...

  15. Comparison of DOE-2.1E with Energyplus and TRNSYS for Ground Coupled Residential Buildings in Hot anf Humid Climates Stage 1

    E-Print Network [OSTI]

    Andolsun, S.; Culp, C.

    2011-01-01T23:59:59.000Z

    of the Function feature in DOE- 2.1C LOADS. Linear interpolations were then done between the sequential three-day average fluxes in DOE-2 in order to produce smoothly varying fluxes for each hour [15]. The daily floor heat fluxes that Huang et al. [15...] obtained from the 2-D finite difference program were calculation assuming 70°F constant zone air temperature all year. The 70°F was the default indoor air temperature that DOE-2 LOADS uses (TLOADS). Huang et al. [15] found that there is a linear...

  16. Self-calibrated active pyrometer for furnace temperature measurements

    DOE Patents [OSTI]

    Woskov, Paul P. (Bedford, MA); Cohn, Daniel R. (Chestnuthill, MA); Titus, Charles H. (Newtown Square, PA); Surma, Jeffrey E. (Kennewick, WA)

    1998-01-01T23:59:59.000Z

    Pyrometer with a probe beam superimposed on its field-of-view for furnace temperature measurements. The pyrometer includes a heterodyne millimeter/sub-millimeter-wave or microwave receiver including a millimeter/sub-millimeter-wave or microwave source for probing. The receiver is adapted to receive radiation from a surface whose temperature is to be measured. The radiation includes a surface emission portion and a surface reflection portion which includes the probe beam energy reflected from the surface. The surface emission portion is related to the surface temperature and the surface reflection portion is related to the emissivity of the surface. The simultaneous measurement of surface emissivity serves as a real time calibration of the temperature measurement. In an alternative embodiment, a translatable base plate and a visible laser beam allow slow mapping out of interference patterns and obtaining peak values therefor. The invention also includes a waveguide having a replaceable end portion, an insulating refractory sleeve and/or a source of inert gas flow. The pyrometer may be used in conjunction with a waveguide to form a system for temperature measurements in a furnace. The system may employ a chopper or alternatively, be constructed without a chopper. The system may also include an auxiliary reflector for surface emissivity measurements.

  17. High temperature synthetic cement retarder

    SciTech Connect (OSTI)

    Eoff, L.S.; Buster, D.

    1995-11-01T23:59:59.000Z

    A synthetic cement retarder which provides excellent retardation and compressive strength development has been synthesized. The response properties and temperature ranges of the synthetic retarder far exceed those of commonly used retarders such as lignosulfonates. The chemical nature of the new retarder is discussed and compared to another synthetic retarder.

  18. Temperature controlled high voltage regulator

    DOE Patents [OSTI]

    Chiaro, Jr., Peter J. (Clinton, TN); Schulze, Gerald K. (Knoxville, TN)

    2004-04-20T23:59:59.000Z

    A temperature controlled high voltage regulator for automatically adjusting the high voltage applied to a radiation detector is described. The regulator is a solid state device that is independent of the attached radiation detector, enabling the regulator to be used by various models of radiation detectors, such as gas flow proportional radiation detectors.

  19. HIGH TEMPERATURE GEOTHERMAL RESERVOIR ENGINEERING

    E-Print Network [OSTI]

    Schroeder, R.C.

    2009-01-01T23:59:59.000Z

    on the Cerro P r i e t o Geothermal F i e l d , Mexicali,e C e r r o P r i e t o Geothermal F i e l d , Baja C a l i1979 HIGH TEMPERATURE GEOTHERMAL RESERVOIR ENGINEERING R.

  20. High temperature lightweight foamed cements

    DOE Patents [OSTI]

    Sugama, Toshifumi (Mastic Beach, NY)

    1989-01-01T23:59:59.000Z

    Cement slurries are disclosed which are suitable for use in geothermal wells since they can withstand high temperatures and high pressures. The formulation consists of cement, silica flour, water, a retarder, a foaming agent, a foam stabilizer, and a reinforcing agent. A process for producing these cements is also disclosed.