Sample records for room air conditioner

  1. Energy conservation standards for room air conditioners

    SciTech Connect (OSTI)

    Rosenquist, G.J. [Lawrence Berkeley National Lab., CA (United States)

    1998-12-31T23:59:59.000Z

    The National Appliance Energy Conservation Act (NAECA) of 1987 established minimum energy-efficiency standards for room air conditioners, which became effective on January 1, 1990. The 1990 minimum energy-efficiency ratios (EER) range from 8.0 to 9.0 (Btu/h)/W (2.34 to 2.64 W/W). As required by NAECA, the Department of Energy (DOE) must also consider amending the room air conditioner standards that went into effect in 1990. As a result, the DOE issued a Notice of Proposed Rulemaking (NOPR) in March 1994 proposing new energy-efficiency standards for several products including room air conditioners. DOE received an extensive number of comments in response to the updated standards that were proposed. A reanalysis was conducted incorporating these comments, resulting in revised estimates of the cost and efficiency increases for more efficient room air conditioner designs. This paper describes the cost-efficiency analysis of design options carried out in support of DOE`s effort to revise the energy-efficiency standards that were proposed for room air conditioners in March 1994. The analysis shows that for the most popular classes of room air conditioners (classes without reverse cycle, with louvered sides, and with capacities ranging from less than 5000 to 20,000 Btu/h [1758 to 5860 W]) EERs of approximately 10.0 (Btu/h)/W (2.93 W/W) can be achieved by incorporating commonly used technologies, such as high-efficiency rotary compressors, grooved refrigerant tubing, slit-type fins, subcoolers, and permanent split capacitor fan motors. Even greater increases in efficiency can be realized with brushless permanent magnet fan motors, enlarged heat exchanger coils, and variable-speed compressors.

  2. ROOM AIR CONDITIONER WALL MOUNTED type

    E-Print Network [OSTI]

    Kleinfeld, David

    SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Reciprocating Compressor Models Indoor unit.6 - 11.4 ----- MOISTURE REMOVAL ( / hr) 2.0 1.8 2.7 2.7 4.3 3 AIR CIRCULATION - Hi (m / hr) 800 800 1

  3. Covered Product Category: Room Air Conditioners

    Broader source: Energy.gov [DOE]

    FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  4. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    Results for Room Air Conditioners Nan Zhou David FridleyTable of Contents I. Air Conditioner Round Robin TestingAir Conditioners..

  5. Technical and economic analysis of energy efficiency of Chinese room air conditioners

    E-Print Network [OSTI]

    Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

    2001-01-01T23:59:59.000Z

    Sector Study of Room Air Conditioners in China) , ChinaQi Shichang ( China’s Air Conditioner Market ), China Lightand Constant-Speed Air Conditioners." ASHRAE Transactions.

  6. Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges

    E-Print Network [OSTI]

    Phadke, Amol

    2014-01-01T23:59:59.000Z

    Efficiency of Room Air Conditioners in India: OpportunitiesStar Labeled room Air Conditioners. ” Ministry of Power (of Superefficient Room Air Conditioners,” Lawrence Berkeley

  7. Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners

    E-Print Network [OSTI]

    McNeil, Michael A.; Iyer, Maithili

    2008-01-01T23:59:59.000Z

    Standard Levels for Room Air Conditioners Michael A. McNeilFigure 1 – MEPS for 1.5 ton Window Air Conditioners – 1994-4 Figure 2 – Air Conditioner Test Data and Rating Plan -

  8. ISSUANCE 2015-06-09: Energy Conservation Program: Energy Conservation Standards for Room Air Conditioners; Request for Information

    Broader source: Energy.gov [DOE]

    Energy Conservation Program: Energy Conservation Standards for Room Air Conditioners; Request for Information

  9. Room Air Conditioners | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingofRetrofittingFundA l i c eRooftop UnitRooftopRoom

  10. Development of a room air conditioner design model

    E-Print Network [OSTI]

    Penson, Steven Brad

    1988-01-01T23:59:59.000Z

    model was developed for this thesis by making major modifications to a heat pump model previously developed by Oak Ridge National Laboratory: (1) Addition of a subcooler, (2) Revision of the capillary tube model, (3) Addition of multi-grooved tubes... circuiting . 11 3. 1 Ideal refrigeration cycle on a pressure-enthalpy diagram 3. 2 3. 3 Tube-in-condensate subcooler. Tube-in-tubs subcooler, . 15 . 17 3. 4 Simplified diagram of a room air conditioner . 19 3. 5 Capillary flow factors. . 30 3. 6...

  11. An Analysis of Efficiency Improvements in Room Air Conditioner 

    E-Print Network [OSTI]

    O'Neal, D. L.; Penson, S. B.

    1988-01-01T23:59:59.000Z

    . There are two public domain models that we have considered using for this analysis: the Oak Ridge National Laboratory (ORNL) heat pump model [1] and the Arthur D. Little (ADL) room air conditioner model [2]. The ORNL model was completed in 1981. Although... regions. 3.2 The Oak Ridge model allows construction of various types of coils using different tube diameters, wall thicknesses, tube spacing, and fin thicknesses. The ORNL model allows use of wavy, louvered, or other fins if data are available...

  12. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    Blast-Type Air Conditioners and Heat Pump. The correspondingair/air air conditioners and heat pumps. Some improvementsconnected air- conditioner (heat pump) units, household

  13. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01T23:59:59.000Z

    Final Summary Report by Air Conditioner Evaluation Standardreversible residential air conditioners and heat pumps usingJFS, 2007: “New Air Conditioners with Infrared Sensors

  14. The Influence of Operating Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner

    E-Print Network [OSTI]

    Yu, J.; Yang, C.; Guo, R.; Wu, D.; Chen, H.

    2006-01-01T23:59:59.000Z

    A field investigation was carried out in an office building of Changsha city in winter and summer, the influence of different running modes, curtain styles and room temperature set point on energy consumption of room air conditioner (RAC...

  15. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    Australia The energy efficiency labeling in Australia adoptson the energy efficiency control list in Australia areenergy efficiency standards and labeling programs for room air conditioners in the United States, European Union, Japan, Australia

  16. Energy Consumption Estimation for Room Air-conditioners Using Room Temperature Simulation with One-Minute Intervals

    E-Print Network [OSTI]

    Wang, F.; Yoshida, H.; Matsumoto, K.

    2006-01-01T23:59:59.000Z

    For the purpose of developing optimized control algorithm for room air-conditioners to ensure their energy efficiency, a short time interval (i.e., one minute) simulation of building thermal performance is necessary because the sampling time...

  17. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01T23:59:59.000Z

    replacement options have and are being developed. Choice of Refrigerant: The most efficient air conditioners

  18. ISSUANCE 2015-07-17: Energy Conservation Program: Energy Conservation Standards for Room Air Conditioners; Request for Information, Extension of the Public Comment Period

    Broader source: Energy.gov [DOE]

    Energy Conservation Program: Energy Conservation Standards for Room Air Conditioners; Request for Information, Extension of the Public Comment Period

  19. Energy Consumption Estimation for Room Air-conditioners Using Room Temperature Simulation with One-Minute Intervals 

    E-Print Network [OSTI]

    Wang, F.; Yoshida, H.; Matsumoto, K.

    2006-01-01T23:59:59.000Z

    of simulated energy consumption can match the measured data. The simulation accuracy of room air temperature and energy consumption during the air-conditioner start-up period is not good and needs to be improved in future research. But in general...

  20. Technical and economic analysis of energy efficiency of Chinese room air conditioners

    SciTech Connect (OSTI)

    Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

    2001-02-01T23:59:59.000Z

    China has experienced tremendous growth in the production and sales of room air conditioners over the last decade. Although minimum room air conditioner energy efficiency standards have been in effect since 1989, no efforts were made during most of the 1990's to update the standard to be more reflective of current market conditions. In 1999, China's State Bureau of Technical Supervision (SBTS) included in their annual plan the development and revision of the 1989 room air conditioner standard, and experts from SBTS worked together with LBNL to analyze the new standards. Based on the engineering and life cycle-cost analyses performed, the most predominant type of room air conditioner in the Chinese market (split-type with a cooling capacity between 2500 and 4500 W (8500 Btu/h and 15,300Btu/h)) can have its efficiency increased cost-effectively to an energy efficiency ratio (EER) of 2.92 W/W (9.9 Btu/hr/W). If an EER standard of 2.92 W/W became effective in 2001, Chinese consumers would be estimated to save over 3.5 billion Yuan (420 million U.S. dollars) over the period of 2001-2020. Carbon emissions over the same period would be reduced by approximately 12 million metric tonnes.

  1. Model-Based Commissioning for Filters in Room Air Conditioners 

    E-Print Network [OSTI]

    Wang, F.; Yoshida, H.; Kitagawa, H.; Matsumoto, K.; Goto, K.

    2004-01-01T23:59:59.000Z

    This paper proposes a model that can estimate filter resistance. Two sorts of value are used as inputs to estimate filter resistance. One is the power consumed by the fan in the indoor unit and the other is the thermal performance. For the room air...

  2. Model-Based Commissioning for Filters in Room Air Conditioners

    E-Print Network [OSTI]

    Wang, F.; Yoshida, H.; Kitagawa, H.; Matsumoto, K.; Goto, K.

    2004-01-01T23:59:59.000Z

    This paper proposes a model that can estimate filter resistance. Two sorts of value are used as inputs to estimate filter resistance. One is the power consumed by the fan in the indoor unit and the other is the thermal performance. For the room air...

  3. Covered Product Category: Room Air Conditioners | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"Wave theJuly 30, 2013DepartmentEnterpriseDepartmentofRoom Air

  4. Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India

    E-Print Network [OSTI]

    McNeil, Michael A.

    2010-01-01T23:59:59.000Z

    for Refrigerators and Air Conditioners in India. Michael A.followed by room air conditioners. Both of these appliancesfrost-free units. Room air conditioners in India have

  5. Techno-Economic Analysis of Indian Draft Standard Levels for RoomAir Conditioners

    SciTech Connect (OSTI)

    McNeil, Michael A.; Iyer, Maithili

    2007-03-01T23:59:59.000Z

    The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency. In support of BEE's refrigerator program, Lawrence Berkeley National Laboratory (LBNL) produced an analysis of national impacts of standards in collaboration with the Collaborative Labeling and Standards Program (CLASP). That analysis drew on LBNL's experience with standards programs in the United States, as well as many other countries. Subsequently, as part of the process for setting optimal levels for air conditioner regulations, CLASP commissioned LBNL to provide support to BEE in the form of a techno-economic evaluation of air conditioner efficiency technologies. This report describes the methodology and results of this techno-economic evaluation. The analysis consists of three components: (1) Cost effectiveness to consumers of efficiency technologies relative to current baseline. (2) Impacts on the current market from efficiency regulations. (3) National energy and financial impacts. The analysis relied on detailed and up-to-date technical data made available by BEE and industry representatives. Technical parameters were used in conjunction with knowledge about air conditioner use patterns in the residential and commercial sectors, and prevailing marginal electricity prices, in order to give an estimate of per-unit financial impacts. In addition, the overall impact of the program was evaluated by combining unit savings with market forecasts in order to yield national impacts. LBNL presented preliminary results of these analyses in May 2006, at a meeting of BEEs Technical Committee for Air Conditioners. This meeting was attended by a wide array of stakeholder, including industry representatives, engineers and consumer advocates. Comments made by stakeholders at this meeting are incorporated into the final analysis presented in this report. The current analysis begins with the Rating Plan drafted by BEE in 2006, along with an evaluation of the market baseline according to test data submitted by manufacturers. MEPS, label rating levels, and baseline efficiencies are presented in Section 2. First, we compare Indian MEPS with current standards in other countries, and assess their relative stringency. Baseline efficiencies are then used to estimate the fraction of models likely to remain on the market at each phase of the program, and the impact on market-weighted efficiency levels. Section 3 deals with cost-effectiveness of higher efficiency design options. The cost-benefit analysis is grounded in technical parameters provided by industry representatives in India. This data allows for an assessment of financial costs and benefits to consumers as a result of the standards and labeling program. A Life-Cycle Cost (LCC) calculation is used to evaluate the impacts of the program at the unit level, thus providing some insight into the appropriateness of the levels chosen, and additional opportunities for further ratcheting. In addition to LCC, we also calculate payback periods, cost of conserved energy (CCE), and return on investment (ROI). Finally, Section 4 covers national impacts. This is an extension of unit level estimates in the two previous sections. Extrapolation to the national level depends on a forecast of air conditioner purchases (shipments), which we describe here. Following the cost-benefit analysis, we construct several efficiency scenarios including the BEE plan, but also considering further potential for efficiency improvement. These are combined with shipments through a stock accounting model in order to forecast air conditioner energy consumption in each sc

  6. Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners

    E-Print Network [OSTI]

    Yu, Bingyi

    2013-01-01T23:59:59.000Z

    Efficiency of Unitary Air Conditioners and Heat Pumps,and Validation of Unitary Air Conditioner and Heat PumpC.W. (1994). Room Air Conditioner System Modeling, Air

  7. 7-55E An office that is being cooled adequately by a 12,000 Btu/h window air-conditioner is converted to a computer room. The number of additional air-conditioners that need to be installed is to be determined.

    E-Print Network [OSTI]

    Bahrami, Majid

    7-20 7-55E An office that is being cooled adequately by a 12,000 Btu/h window air-conditioner is converted to a computer room. The number of additional air-conditioners that need to be installed/h. Then noting that each available air conditioner provides 4,000 Btu/h cooling, the number of air- conditioners

  8. Covered Product Category: Residential Central Air Conditioners...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Central Air Conditioners Covered Product Category: Residential Central Air Conditioners The Federal Energy Management Program (FEMP) provides acquisition guidance for residential...

  9. Life-cycle cost and payback period analysis for commercial unitary air conditioners

    E-Print Network [OSTI]

    Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

    2004-01-01T23:59:59.000Z

    Baseline Efficient Air Conditioners . . . . . . 28 AverageEfficient Air Conditioners . . . . . . . . . . . . . . . . .Btu/h Commercial Air Conditioners . . . . . . . . . . . . .

  10. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    SciTech Connect (OSTI)

    Zhou, Nan; Fridley, David; Zheng, Nina; Pierrot, Andre

    2010-06-07T23:59:59.000Z

    In recent years China's energy consumption has increased rapidly. The problem of high energy consumption intensity and low energy utilization efficiency is serious, and the contradiction between economic development and energy and environmental resources has become increasingly acute, making energy conservation and consumption reduction an important society-wide concern. At the same time, global climate change has and will continue to have profound impacts on human survival and development, and is another major challenge to all countries. In order to accelerate China's energy conservation and emission reduction work, the National Leading Group to Address Climate Change, Energy Conservation and Emission Reduction was founded with Premier Wen Jiabao as the head, and the 'Comprehensive Work Program of Energy Conservation and Emission Reduction' and 'China's National Program of Addressing Climate Change' were issued, under which China's energy conservation and emission reduction work has been fully deployed. Efforts to promote energy efficiency have been further strengthened in all levels of government, and various policies and measures have progressively been issued and implemented. In addition, based on China's experience with implementing energy-saving priority strategies over the past 20+ years, our government established a goal of a 20% decrease in energy consumption per unit GDP in the 'Eleventh Five-year Development Plan'. Furthermore, in November 2009, in order to support global greenhouse gas emission reduction activities and promote China's low carbon economic development, the government established a further 40-50% reduction in energy consumption per unit GDP by 2020 compared to the year 2005. Improving energy utilization efficiency by scientific and technological progress will undoubtedly play an important role in achieving the above stated objectives. The improvement of energy efficiency of energy consuming products has always been an important component of all countries energy strategies. As we all know, a very large amount of total energy consumption is due to energy consuming products and equipment, which account for about 50% of China's total energy consumption. However, the current average energy utilization efficiency of this sector is only about 60%, 10 percent lower than the international advanced level. Therefore, China's energy consuming products and equipment sector holds great energy-saving potential. On the other hand, the energy supplied to these products is mainly from fossil fuel combustion, a major source of greenhouse gas (GHG) emissions. Therefore, improving the energy efficiency and augmenting the market share of market-dominant energy consuming products is of significant importance to achieving China's energy saving and emission reduction target and is an effective means to deal with energy and environmental constraints and climate change issues. Main energy consuming products generally include widely-used home appliances, industrial equipment, office equipment, transportation vehicles, etc. China is one of the major manufacturers and exporters of energy end-using products such as air-conditioners, refrigerators, televisions, etc. Their overall energy efficiency is comparatively low and the products are poorly designed, leading to great energy-saving potential. For example, electricity consumption of air conditioners accounts for about 20% of China's total electricity consumption and 40% of the summer electricity peak load in large and medium cities. However, less than 5% of units sold in the domestic market in 2009 reached the standard's highly efficient level of grade 2 above. The electricity consumption of electric motors and their related drive systems accounts for about 60% of China's total electricity consumption; however, less than 2% of the domestic market share consists of energy-efficient electric motor products. Promoting the energy efficiency and market shares of main energy-consuming products has become an important determinant of achieving energy conservation and emission reduc

  11. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01T23:59:59.000Z

    HETAC, “High Efficiency Thermal Air Conditioning”, http://Refrigeration and Air Conditioning Industry Association,variable air volume air conditioning system for buildings”,

  12. Determining benefits and costs of improved central air conditioner efficiencies

    E-Print Network [OSTI]

    Rosenquist, G.

    2010-01-01T23:59:59.000Z

    Products: Central Air Conditioners and Heat Pumps Energyof Improved Central Air Conditioner Efficiencies Authorsresidential-type central air conditioner energy-efficiency

  13. Dirty air conditioners: Energy implications of coil fouling

    E-Print Network [OSTI]

    Siegel, Jeffrey; Walker, Iain; Sherman, Max

    2002-01-01T23:59:59.000Z

    1473. Neal, L. 1992. Air Conditioner Efficiency in the Realof a Residential Air Conditioner. Proceedings of the 1992of new residential air conditioners in Phoenix, Arizona.

  14. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    C Dry bulb. air inlet. indoor side ºC Wet bulb. air inlet.indoor side ºC Dry bulb. air outlet.indoor side ºC Wet bulb. air outlet. indoor side ºC

  15. Air Conditioner User Behavior in a Master-Metered Apartment Building

    E-Print Network [OSTI]

    Kempton, W.; Feuermann, D.; McGarity, A. E.

    1987-01-01T23:59:59.000Z

    Air conditioner operation was studied in order to understand how energy consumption and peak power are determined by user behavior, equipment operation and building characteristics. In a multi-family building, thirteen room air conditioners were...

  16. Influence of Air Conditioner Operation on Electricity Use and Peak Demand

    E-Print Network [OSTI]

    McGarity, A. E.; Feuermann, D.; Kempton, W.; Norford, L. K.

    1987-01-01T23:59:59.000Z

    Electricity demand due to occupant controlled room air conditioners in a large mater-metered apartment building is analyzed. Hourly data on the electric demand of the building and of individual air conditioners are used in analyses of annual...

  17. DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS

    E-Print Network [OSTI]

    Dao, K.

    2013-01-01T23:59:59.000Z

    DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS K. Dao, M.ABSORPTION AIR CONDITIONERS AND HEAT PUMPS* K. DAO, M.

  18. AIR CONDITIONER REQUEST EXTREME MEDICAL CIRCUMSTANCES

    E-Print Network [OSTI]

    AIR CONDITIONER REQUEST DUE TO EXTREME MEDICAL CIRCUMSTANCES TO BE COMPLETED BY ATTENDING Moderate Significant Is the use of an air conditioner desirable Yes No OR essential Yes No to the management of allergy? Is the use of an air conditioner

  19. High-Efficiency Window Air Conditioners - Building America Top...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    High-Efficiency Window Air Conditioners - Building America Top Innovation High-Efficiency Window Air Conditioners - Building America Top Innovation This photo shows a window air...

  20. Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners

    E-Print Network [OSTI]

    Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners John Shugars, Consultant ofcommercialpackaged air conditioners, explore the reasons behindthis efficiency gap, and assess opportunities). Although sales of rooftop air conditioners have steadily increased over the past decade, the efficiency

  1. DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS

    E-Print Network [OSTI]

    Dao, K.

    2013-01-01T23:59:59.000Z

    SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS K.Driven Absorption Air-Conditioner", K. Dao, M. Simmons, R.SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS* K.

  2. Four Central Air Conditioners Determined Noncompliant With Energy...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard October...

  3. Electrolux Gibson Air Conditioner and Equator Clothes Washer...

    Broader source: Energy.gov (indexed) [DOE]

    Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing...

  4. Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement

    E-Print Network [OSTI]

    Bode, Josh

    2013-01-01T23:59:59.000Z

    Measuring Short-term Air Conditioner Demand Reductions forMeasuring Short-term Air Conditioner Demand Reductions forpilots have shown that air conditioner (AC) electric loads

  5. Rating of Mixed Split Residential Air Conditioners

    E-Print Network [OSTI]

    Domanski, P. A.

    1988-01-01T23:59:59.000Z

    A methodology is presented for rating the performance of mixed, split residential air conditioners. The method accounts for the impact on system performance of the indoor evaporator, expansion device and fan; three major components that are likely...

  6. Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges

    E-Print Network [OSTI]

    Phadke, Amol

    2014-01-01T23:59:59.000Z

    Heating, Refrigerating and Air-Conditioning Engineers, 2012.EER for the base case air conditioning unit is taken as the

  7. Stirling Air Conditioner for Compact Cooling

    SciTech Connect (OSTI)

    None

    2010-09-01T23:59:59.000Z

    BEETIT Project: Infinia is developing a compact air conditioner that uses an unconventional high efficient Stirling cycle system (vs. conventional vapor compression systems) to produce cool air that is energy efficient and does not rely on polluting refrigerants. The Stirling cycle system is a type of air conditioning system that uses a motor with a piston to remove heat to the outside atmosphere using a gas refrigerant. To date, Stirling systems have been expensive and have not had the right kind of heat exchanger to help cool air efficiently. Infinia is using chip cooling technology from the computer industry to make improvements to the heat exchanger and improve system performance. Infinia’s air conditioner uses helium gas as refrigerant, an environmentally benign gas that does not react with other chemicals and does not burn. Infinia’s improvements to the Stirling cycle system will enable the cost-effective mass production of high-efficiency air conditioners that use no polluting refrigerants.

  8. Avoiding 100 new power plants by increasing efficiency of room air conditioners in India: opportunities and challenges

    SciTech Connect (OSTI)

    Phadke, Amol; Abhyankar, Nikit; Shah, Nihar; [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

    2013-10-15T23:59:59.000Z

    Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40% cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

  9. Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges

    SciTech Connect (OSTI)

    Phadke, Amol; Abhyankar, Nikit; Shah, Nihar

    2014-06-19T23:59:59.000Z

    Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40percent cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

  10. The effects of galvanic corrosion on air conditioner performance

    E-Print Network [OSTI]

    Grisham, Phillip Ryan

    2001-01-01T23:59:59.000Z

    Corrosion of air conditioner outdoor heat exchangers (condensers) poses a significant problem for consumers living in coastal regions. This research sought to experimentally determine effects of galvanic corrosion on air conditioner condenser coils...

  11. Covered Product Category: Residential Central Air Conditioners

    Broader source: Energy.gov [DOE]

    FEMP provides acquisition guidance across a variety of product categories, including residential central air conditioners (CACs), which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  12. EECBG Direct Equipment Purchase Air Conditioner Guide Equipment Type

    E-Print Network [OSTI]

    EECBG Direct Equipment Purchase Air Conditioner Guide Equipment Type Size Category (Btu/h) Size.ahridirectory.org/ceedirectory/pages/ac/cee/defaultSearch.aspx 12,000 Btu/h = 1 ton Less than 65,000 Btu/h Air Conditioners, Air Cooled Air Conditioners, Water completed by the California Energy Commission at a rate of 12,000 Btu/h per ton of air conditioning Source

  13. APPROVED ICE STORAGE AIR CONDITIONERS Revised as of 06-18-2008

    E-Print Network [OSTI]

    APPROVED ICE STORAGE AIR CONDITIONERS Revised as of 06-18-2008 The following vendors and their ice storage air conditioners models can be used in the ice storage air conditioner compliance option. Input

  14. DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner...

    Energy Savers [EERE]

    Action Against AeroSys, Inc. for Failure to Certify Air Conditioners and Heat Pumps Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard...

  15. Air Conditioner Compressor Performance Model

    SciTech Connect (OSTI)

    Lu, Ning; Xie, YuLong; Huang, Zhenyu

    2008-09-05T23:59:59.000Z

    During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.

  16. absorption air conditioner: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    absorption air conditioner First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 AIR CONDITIONER REQUEST...

  17. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology

    SciTech Connect (OSTI)

    Not Available

    1993-11-01T23:59:59.000Z

    The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

  18. An Evaluation of the Effects of Refrigerant Charge on a Residential Central Air Conditioner with Orifice Expansion 

    E-Print Network [OSTI]

    O'Neal, D. L.; Ramsey, C. J.; Farzad, M.

    1989-01-01T23:59:59.000Z

    conditioning and heat pump performance testing. Dew point and room temperatures can be maintained within +/-0.2 F of the set point. The room temperature was controlled by a Texas Instruments TI-550 controller which was integrated into the control system... Air Conditioner with Capillary Tube Expansion", ESL/CON/88-1, Energy Systems Laboratory, Texas A&M University, July 1988. 2. Department of Energy, "Test Procedures for Central Air- Conditioners, Including Heat Pumps", Federal Register, pp. 76700...

  19. Commercial Central Air Conditioners, Purchasing Specifications for Energy-Efficient Products (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2011-02-01T23:59:59.000Z

    Energy efficiency purchasing specifications for federal procurements of commercial central air conditioners.

  20. Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates 

    E-Print Network [OSTI]

    O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

    1996-01-01T23:59:59.000Z

    provided rebates to residential customers for purchasing high efficiency air conditioners and heat pumps. The rebates have helped increase the demand for higher efficiency air conditioning units. However, even the most efficient system will not perform... quanm the effect of air leakage in the return air duct from a hot attic space on the high-temperature performance of air conditioners and heat pump systems. Air conditioner performance is quantified in terms of capacity, Energy Efficiency Ratio (EER...

  1. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    E-Print Network [OSTI]

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-01-01T23:59:59.000Z

    Central Air Conditioners and Heat Pumps Energy ConservationCentral Air Conditioners and Heat Pumps. Washington DC:Central Air Conditioners and Heat Pumps Energy Conservation

  2. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    E-Print Network [OSTI]

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-01-01T23:59:59.000Z

    Products: Central Air Conditioners and Heat Pumps EnergyResidential Central Air Conditioners and Heat Pumps.Products: Central Air Conditioners and Heat Pumps Energy

  3. YMGI Through-the-Wall Air Conditioner Determined Noncompliant...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    on October 11, 2012, to YMGI Group, LLC (YMGI) regarding through-the-wall split system central air conditioner basic model TTWC-18K-31B. DOE enforcement testing revealed that...

  4. DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS

    E-Print Network [OSTI]

    Dao, K.

    2013-01-01T23:59:59.000Z

    AIR CONDITIONERS AND HEAT PUMPS K. Dao, M. Wahlig, E. Wali,are liquid paths. DM: multistage pump driver, driven by highvapor. DW: main circulation pump driven by strong absorbent.

  5. adsorption air conditioner: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    establishment of a network of solarair conditioner is an Arkla gas-fired ammonia-water chiller, modified for operation using solar- Dols, C. 2010-01-01 177 Air Pollution Spring...

  6. automobile air conditioners: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    (1) and the establishment of a network of solarair conditioner is an Arkla gas-fired ammonia-water chiller, modified for operation using solar- Dols, C. 2010-01-01 263 Air...

  7. Improving Air-Conditioner and Heat Pump Modeling (Presentation)

    SciTech Connect (OSTI)

    Winkler, J.

    2012-03-01T23:59:59.000Z

    A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

  8. Residential Air Conditioner Direct Load Control "Energy Partners Program"

    E-Print Network [OSTI]

    Cook, J. D.

    1994-01-01T23:59:59.000Z

    RESIDENTIAL AIR CONDITIONER DIRECT LOAD CONTROL "ENERGY PARTNERS PROGRAMn John D. Cook Supervisor Houston ABSTRACT Demand side management programs like Energy Partners can provide an effective peak reducing capability which within a.... In this partnership the customer allows HLfP to install a I switch on his/her air conditioner or heat pump and i periodically cycle the unit off during the hottest summer 1 days. In return the customer benefits by receiving an incentive payment, as well...

  9. Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners

    E-Print Network [OSTI]

    Yu, Bingyi

    2013-01-01T23:59:59.000Z

    of Unitary Air Conditioners and Heat Pumps, ASHRAE, 1791of Unitary Air Conditioner and Heat Pump Simulation Modelsfor Rating Unitary Air-Conditioning and Heat Pump Equipment,

  10. STRATEGIC PLAN TO REDUCE THE ENERGY IMPACT OF AIR CONDITIONERS

    E-Print Network [OSTI]

    CALIFORNIA ENERGY COMMISSION STRATEGIC PLAN TO REDUCE THE ENERGY IMPACT OF AIR CONDITIONERS Acknowledgements This report represents the efforts of many experts from the air conditioning industry who Manufacturer Freus Air Conditioning Jim Bazemore Consultant Energy Market Innovations, Inc. Doug Beaman

  11. Installation of Window Air Conditioners Page 1 of 2 Virginia Polytechnic Institute and State University No. 5705 Rev.: 3

    E-Print Network [OSTI]

    Buehrer, R. Michael

    Installation of Window Air Conditioners Page 1 of 2 Virginia Polytechnic Institute and State __________________________________________________________________________________ Subject: Installation of Window Air Conditioners........................................................................................................................................1 1. Purpose To define a policy for installation of window air conditioners that avoids exterior

  12. Truman STaTe univerSiTyWELCOME HOME! Air Conditioner

    E-Print Network [OSTI]

    Gering, Jon C.

    Truman STaTe univerSiTyWELCOME HOME! Air Conditioner Welcome toTruman State University air conditioner requests.If you need air conditioning and are assigned to Centennial,Grim,or Fair conditioning, you will need to bring your own air conditioner unit that is 6000 BTUs or less.A non

  13. STATE OF CALIFORNIA CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS

    E-Print Network [OSTI]

    STATE OF CALIFORNIA CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS CEC Volume Single Zone Unitary Air Conditioner and Heat Pump Systems (Page 1 of 4) Project Name CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS CEC-MECH-3A (Revised 08

  14. Laboratory Performance Testing of Residential Window Air Conditioners

    SciTech Connect (OSTI)

    Winkler, J.; Booten, C.; Christensen, D.; Tomerlin, J.

    2013-03-01T23:59:59.000Z

    Window air conditioners are the dominant cooling product for residences, in terms of annual unit sales. They are inexpensive, portable and can be installed by the owner. For this reason, they are an attractive solution for supplemental cooling, for retrofitting air conditioning into a home which lacks ductwork, and for renters. Window air conditioners for sale in the United States are required to meet very modest minimum efficiency standards. Four window air conditioners' performance were tested in the Advanced HVAC Systems Laboratory on NREL's campus in Golden, CO. In order to separate and study the refrigerant system's performance, the unit's internal leakage pathways, the unit's fanforced ventilation, and the leakage around the unit resulting from installation in a window, a series of tests were devised that focused on each aspect of the unit's performance. These tests were designed to develop a detailed performance map to determine whole-house performance in different climates. Even though the test regimen deviated thoroughly from the industry-standard ratings test, the results permit simple calculation of an estimated rating for both capacity and efficiency that would result from a standard ratings test. Using this calculation method, it was found that the three new air conditioners' measured performance was consistent with their ratings. This method also permits calculation of equivalent SEER for the test articles. Performance datasets were developed across a broad range of indoor and outdoor operating conditions, and used them to generate performance maps.

  15. Monitoring and evaluation of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached houses in Austin, Texas

    SciTech Connect (OSTI)

    Burns, R.; Hough, R.E. (Fleming (W.S.) and Associates, Inc., Syracuse, NY (United States))

    1991-10-01T23:59:59.000Z

    The US DOE initiated this project to evaluate the performance of an air conditioner retrofit program in Austin, Texas. The City's Austin's Resource Management Department pursued this project to quantify the retrofit effect of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached homes. If successfully implemented, this retrofit program could help defer construction of a new power plant which is a major goal of this department. The project compares data collected from 12 houses during two cooling seasons under pre-retrofit and then post-retrofit air conditioner units. The existing low-efficiency air conditioners were monitored during the 1987 cooling season, replaced during the 1987--88 heating season with new, smaller sized, high-efficiency units, and then monitored again during the 1988 cooling season. Results indicated that the air conditioner retrofits reduce the annual air conditioner electric consumption and peak electric demand by an average of 38%. When normalized to the nominal capacity of the air conditioner, average demand savings were 1.12 W/ft{sup 2} and estimated annual energy savings were 1.419 kWh/ft{sup 2}. Individual air conditioner power requirements were found to be a well defined function of outdoor temperature as expected. In the absence of detailed data, estimates of the peak demand reductions of new air conditioners can be made from the manufacturer's specifications. Air conditioner energy consumption proved to be strongly linear as a function of the outdoor temperature as expected when taken as an aggregate. No noticeable differences in the diversity factor of the air conditioner usage were found. Analysis of the retrofit effect using PRISM yields estimates of the reduction in normalized annual consumption (NAC) and annual cooling consumption of 12% and 30%. 2 refs., 11 figs., 17 tabs.

  16. Development of vehicle magnetic air conditioner (VMAC) technology. Final report

    SciTech Connect (OSTI)

    Gschneidner, Karl A., Jr.; Pecharsky, V.K.; Jiles, David; Zimm, Carl B.

    2001-08-28T23:59:59.000Z

    The objective of Phase I was to explore the feasibility of the development of a new solid state refrigeration technology - magnetic refrigeration - in order to reduce power consumption of a vehicle air conditioner by 30%. The feasibility study was performed at Iowa State University (ISU) together with Astronautics Corporation of America Technology Center (ACATC), Madison, WI, through a subcontract with ISU.

  17. Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners

    E-Print Network [OSTI]

    Yu, Bingyi

    2013-01-01T23:59:59.000Z

    cooling energy efficiency ratio for split-system air conditioners is not well characterized. This research

  18. Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates

    E-Print Network [OSTI]

    O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

    1996-01-01T23:59:59.000Z

    were designed for testing systems with cooling capacities of up to 10 tons. The unit used for return air leakage tests was a 3.5 ton (12.3 kW) split system air conditioner with TXV expansion and a scroll compressor. It had a seasonal energy... leakage on capacity, power, and energy efficiency ratio (EER) of an air conditioner were quantified. The air conditioner was subjected to an outdoor temperature of 100°F (37.g°C). The indoor conditions for the no leakage test were set at 75OF (23.g...

  19. Room Air Conditioners | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic2 OPAM615_CostNSAR -DepartmentRetailEnergy Role of Modeling andSoft Costs

  20. Room Air Conditioners | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro Industries Pvt Ltd Jump to: navigation,MazeOhio:Ohio:RockwallRolling

  1. Room Air Conditioners | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently AskedEnergy SmallImplementing theFinancing » Financing, 2003Ronald A.Soft Costs

  2. Assessment of Environmentally Friendly Refrigerants for Window Air Conditioners

    SciTech Connect (OSTI)

    Bansal, Pradeep [ORNL] [ORNL; Shen, Bo [ORNL] [ORNL

    2014-01-01T23:59:59.000Z

    This paper presents technical assessment of environmentally friendly refrigerants for window air conditioners that currently use refrigerant R410A for residential and commercial applications. The alternative refrigerants that are studied for its replacement include R32, R600a, R290, R1234yf, R1234ze and a mixture of R32 (90% molar concentration) and R125 (10% molar concentration). Baseline experiments were performed on a window unit charged with R410A. The ORNL Heat Pump Design Model was calibrated with the baseline data and was used to assess the comparative performance of the WAC with alternative refrigerants. The paper discusses the advantages and disadvantages of each refrigerants and their suitability for window air conditioners.

  3. Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype

    SciTech Connect (OSTI)

    Kozubal, E.; Woods, J.; Judkoff, R.

    2012-04-01T23:59:59.000Z

    This report documents the design of a desiccant enhanced evaporative air conditioner (DEVAP AC) prototype and the testing to prove its performance. Previous numerical modeling and building energy simulations indicate a DEVAP AC can save significant energy compared to a conventional vapor compression AC (Kozubal et al. 2011). The purposes of this research were to build DEVAP prototypes, test them to validate the numerical model, and identify potential commercialization barriers.

  4. The Impact of Energy Recovery on Window Air-conditioner Efficiency

    E-Print Network [OSTI]

    Luo, Q.; Tang, C.; Liao, K.

    2006-01-01T23:59:59.000Z

    An experimental energy recovering air-conditioner can produce fresh air exchange heat with exhaust air in the heat exchanger, which has no additional moving parts. The EER of the experimental air-conditioner (EAC) is increased by 17.4~37.3 percent...

  5. Determining benefits and costs of improved central air conditioner efficiencies

    SciTech Connect (OSTI)

    Rosenquist, G.; Levok, A.; Chan, P.; McMahon, J.

    2001-01-12T23:59:59.000Z

    Economic impacts on individual consumers from possible revisions to U.S. residential-type central air conditioner energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a central air conditioner and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers due to modest increases in efficiency are significant. For an efficiency increase of 20percent over the existing minimum standard (i.e., 12 SEER), 35percent of households with central air conditioners experience significant LCC savings, with an average savings of $453, while 25percent show significant LCC losses, with an average loss of $158 compared to apre-standard LCC average of $5,170. The remainder of the population (40percent) are largely unaffected.

  6. Advanced Thin Film Thermoelectric Systems forEfficient Air-Conditioner...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    device fabrication and the design of novel coolingheating engines exploiting thermal storage for efficient air-conditioners in automobiles ghoshal.pdf More Documents &...

  7. 2015-02-12 Issuance: Test Procedures for Portable Air Conditioners...

    Broader source: Energy.gov (indexed) [DOE]

    to this document. PAC TP NOPR.pdf More Documents & Publications 2014-05-05 Issuance: Test Procedure for Portable Air Conditioners; Notice of Data Availability ISSUANCE...

  8. Measured Impacts of Air Conditioner Condenser Shading

    E-Print Network [OSTI]

    Parker, D. S.; Barkaszi, S. F.; Sonne, J. K.

    1996-01-01T23:59:59.000Z

    A study has been conducted by the Florida Solar Energy Center (FSEC) to examine if space cooling energy savings can be achieved from shading of residential air conditioning (AC) condenser units. The investigation consisted of before...

  9. Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications: Preprint

    SciTech Connect (OSTI)

    Lowenstein, A.; Slayzak, S.; Kozubal, E.

    2006-07-01T23:59:59.000Z

    A novel liquid-desiccant air conditioner that dries and cools building supply air will transform the use of direct-contact liquid-desiccant systems in HVAC applications, improving comfort, air quality, and providing energy-efficient humidity control.

  10. Problem Type Problem Type Description Air Conditioning Air conditioner not working, leaking, etc

    E-Print Network [OSTI]

    Tennessee, University of

    Problem Type Problem Type Description Air Conditioning Air conditioner not working, leaking, etc, Microfridges Doors and Hardware Door repair/replace Lock, latch or hinge repair, key stuck; Lost or stolen key, repair or replace Shades/Blinds Window treatment - repair or replace Washer/Dryer Washer/Dryer repair

  11. Commissioning Tools for Heating/Cooling System in Residence - Verification of Floor Heating System and Room Air Conditioning System Performance 

    E-Print Network [OSTI]

    Miura, H.; Hokoi, S.; Iwamae, A.; Umeno, T.; Kondo, S.

    2004-01-01T23:59:59.000Z

    Tools of evaluating the performance of floor heating and room air conditioner are examined as a commissioning tool. Simple method is needed to check these performance while in use by residents, because evaluation currently requires significant time...

  12. Commissioning Tools for Heating/Cooling System in Residence - Verification of Floor Heating System and Room Air Conditioning System Performance

    E-Print Network [OSTI]

    Miura, H.; Hokoi, S.; Iwamae, A.; Umeno, T.; Kondo, S.

    2004-01-01T23:59:59.000Z

    Tools of evaluating the performance of floor heating and room air conditioner are examined as a commissioning tool. Simple method is needed to check these performance while in use by residents, because evaluation currently requires significant time...

  13. An Evaluation of Steady-State Dehumidification Characteristics of Residential Central Air Conditioners, Final Report

    E-Print Network [OSTI]

    O'Neal, D. L.; Chan, N.; Somasundaram, S.; Katipamula, S.

    1987-01-01T23:59:59.000Z

    Conditioners, Air Source HeatPumps, and Sound-Rated Outdoor Unitary Equipment that ARI publishes twice a yearCl], In addition to the ARI certification, many manufacturerspublish detailed performance (capacity, efficiency, and dehumidification) data....2 - Performance and hardware data collectedfor this survey. 3.2 References 1. "Directory of Certified Unitary Air Conditioners, Air Source HeatPumps, and Sound-Rated Outdoor Unitary Equipment", Semi-Annual Issues, Air Conditioning and Refrigeration Institute...

  14. Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India

    SciTech Connect (OSTI)

    McNeil, Michael A.; Iyer, Maithili

    2009-05-30T23:59:59.000Z

    The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

  15. An Analysis of Efficiency Improvements in Residential Sized Heat Pumps and Central Air Conditioners 

    E-Print Network [OSTI]

    O'Neal, D. L.; Boecker, C. L.; Penson, S. B.

    1986-01-01T23:59:59.000Z

    This report summarizes: (1) the performance improvements possible for central air conditioners and heat pumps using conventional design improvements, (2) the development of a methodology for estimating the seasonal performance of variable speed heat...

  16. Determination of the Transient Dehumidification Characteristics of High Efficiency Central Air Conditioners 

    E-Print Network [OSTI]

    Katipamula, S.; O'Neal, D. L.; Somasundaram, S.

    1987-01-01T23:59:59.000Z

    A series of tests were performed to assesses the dehumidifying performance of residential central air conditioners (CACs). The performance studies were based on factors such as: (i) dynamic performance (ii) the ASHRAE ...

  17. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations

    SciTech Connect (OSTI)

    Cutler, D.; Winkler, J.; Kruis, N.; Christensen, C.; Brendemuehl, M.

    2013-01-01T23:59:59.000Z

    This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost effective equipment upgrade opportunities and efficiency improvements in residential buildings.

  18. Modeling the effects of Refrigerant Charging on Air Conditioner Performance Characteristics For Three Expansion Devices

    E-Print Network [OSTI]

    Farzad, Mohsen

    An experimental and analytical study concerned with the off-design refrigerant charging of air conditioners is presented. A series of experiments were conducted to characterize the effects of refrigerant charge and type of expansion device...

  19. A Preliminary Evaluation of Alternative Liquid Desiccants for a Hybrid Desiccant Air Conditioner

    E-Print Network [OSTI]

    Studak, J. W.; Peterson, J. L.

    1988-01-01T23:59:59.000Z

    and the condenser of a vapor-compression air conditioner. The liquid desiccants studied were lithium chloride, lithium bromide, calcium chloride, and triethylene glycol. Each candidate desiccant was subjected to a screening process which weighed the merits...

  20. The Impact of Residential Air Conditioner Charging and Sizing on Peak Electrical Demand 

    E-Print Network [OSTI]

    Neal, L.; O'Neal, D. L.

    1992-01-01T23:59:59.000Z

    . Dennis L. O'Neal Department of Mechanical Engineering Texas A & M University College Station, TX Federal and state governments can also impact the choice of central air conditioners/heat pumps through requirements mandated by legislation.... The National Energy Efficient Appliances Act requires an SEER of JO for all split-system central air conditioners or heat pumps manufactured after January 1, 1992, and an SEER of 9.7 for all package systems manufactured after January 1, 1993 [I]. Electric...

  1. Applying a Domestic Water-cooled Air-conditioner in Subtropical Cities

    E-Print Network [OSTI]

    Lee, W.; Chen, H.

    2006-01-01T23:59:59.000Z

    the energy and environmental benefits of WACS over AACS applying to commercial buildings with central air-conditioning. This paper presents an experimental study on the performance of a 3.36 kW prototype water-cooled air conditioner. The prototype is a self...

  2. ISSUANCE 2015-06-08: Energy Conservation Program: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps, Final Rule

    Broader source: Energy.gov [DOE]

    Energy Conservation Program: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps, Final Rule

  3. Swozzle based burner tube premixer including inlet air conditioner for low emissions combustion

    DOE Patents [OSTI]

    Tuthill, Richard Sterling (Bolton, CT); Bechtel, II, William Theodore (Scotia, NY); Benoit, Jeffrey Arthur (Scotia, NY); Black, Stephen Hugh (Duanesburg, NY); Bland, Robert James (Clifton Park, NY); DeLeonardo, Guy Wayne (Scotia, NY); Meyer, Stefan Martin (Troy, NY); Taura, Joseph Charles (Clifton Park, NY); Battaglioli, John Luigi (Glenville, NY)

    2002-01-01T23:59:59.000Z

    A burner for use in a combustion system of a heavy-duty industrial gas turbine includes a fuel/air premixer having an air inlet, a fuel inlet, and an annular mixing passage. The fuel/air premixer mixes fuel and air into a uniform mixture for injection into a combustor reaction zone. The burner also includes an inlet flow conditioner disposed at the air inlet of the fuel/air premixer for controlling a radial and circumferential distribution of incoming air. The pattern of perforations in the inlet flow conditioner is designed such that a uniform air flow distribution is produced at the swirler inlet annulus in both the radial and circumference directions. The premixer includes a swozzle assembly having a series of preferably air foil shaped turning vanes that impart swirl to the airflow entering via the inlet flow conditioner. Each air foil contains internal fuel flow passages that introduce natural gas fuel into the air stream via fuel metering holes that pass through the walls of the air foil shaped turning vanes. By injecting fuel in this manner, an aerodynamically clean flow field is maintained throughout the premixer. By injecting fuel via two separate passages, the fuel/air mixture strength distribution can be controlled in the radial direction to obtain optimum radial concentration profiles for control of emissions, lean blow outs, and combustion driven dynamic pressure activity as machine and combustor load are varied.

  4. An Evaluation of Steady-State Dehumidification Characteristics of Residential Central Air Conditioners, Final Report 

    E-Print Network [OSTI]

    O'Neal, D. L.; Chan, N.; Somasundaram, S.; Katipamula, S.

    1987-01-01T23:59:59.000Z

    Conditioners, Air Source HeatPumps, and Sound-Rated Outdoor Unitary Equipment that ARI publishes twice a yearCl], In addition to the ARI certification, many manufacturerspublish detailed performance (capacity, efficiency, and dehumidification) data... due to on-off cycling is estimated and used with data fromTest B to calculate the Seasonal Energy Efficiency Ratio (SEER). *The test procedure used to rate air conditioners and heat pumps isreproduced in the appendix. 2.1 (2.1) where, While the amount...

  5. Are You Planning to Bring an Air Conditioner? Welcome to Truman State University and the services available through the Disability Services Office. Part of

    E-Print Network [OSTI]

    Gering, Jon C.

    Are You Planning to Bring an Air Conditioner? Welcome to Truman State University and the services conditioner requests. If you need air conditioning and are assigned to Centennial, Grim, or Fair Apartments conditioning, you will need to bring your own air conditioner unit that is 6000 BTUs or less. A non

  6. China Energy Efficiency Round Robin Testing Results for Room

    E-Print Network [OSTI]

    LBNL-3502E China Energy Efficiency Round Robin Testing Results for Room Air Conditioners Nan Zhou Berkeley National Laboratory is an equal opportunity employer. #12;i Table of Contents I. Air Conditioner.......................................................................................................................... 6 I.2.1 Necessity for Air Conditioner Round Robin Testing

  7. Air Conditioner Efficiency Under Hot Dry and Hot Humid Conditions - The Utility Perspective

    E-Print Network [OSTI]

    Amarnath, A.

    94304 E-mail: aamarnath@epri.com Phone: (650) 855-1007 Energy efficient residential air conditioning is important to utilities and their customers. In almost all parts of the U.S., an air conditioner for a dwelling has a high peak demand... energy efficiency programs; ? Actively engage in the USDOE standards proceedings through technical input from collaborative organizations like EPRI and EEI; ? Support emerging technology procurement of air conditioning equipment that is super...

  8. 13 SEER Standard for Central Air Conditioners and Heat Pumps (released in AEO2005)

    Reports and Publications (EIA)

    2005-01-01T23:59:59.000Z

    In January 2004, after years of litigation in a case that pitted environmental groups and Attorneys General from 10 states against the U.S. Secretary of Energy, the U.S. Court of Appeals for the Second Circuit reestablished the central air conditioner and heat pump standard originally set in January 200. The Courts ruling, which struck down a May 2002 rollback of the 2001 standard to a 12 Seasonal Energy Efficiency Ratio (SEER) mandates that all new central air conditioners and heat pumps meet a 13 SEER standard by January 2006, requiring a 30% increase in efficiency relative to current law. The Annual Energy Outlook 2005 reference case incorporates the 13 SEER standard as mandated by the Courts ruling.

  9. air conditioner units: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Air Service White Paper series. The ... Wittman, Michael D. 2013-05-07 65 Proposal for an Adsorption Solar-Driven Air-Conditioning Unit for Public Offices Texas A&M University -...

  10. An Analysis of Efficiency Improvements in Room Air Conditioner

    E-Print Network [OSTI]

    O'Neal, D. L.; Penson, S. B.

    1988-01-01T23:59:59.000Z

    and Evaporator Models 3.2 Model Output 3.4 Conclusions and Model Selection 3.4 References 3.5 4 MODEL DEVELOPMENT 4.1 Identification of Changes 4.1 Subcooler 4.2 Condensate Spray 4.2 Roughened Tubes 4.7 Capillary Tube Model Modifications 4.7 Correlations 4....7 Subcooler 4.8 Wet Condenser 4.10 Roughened Tubes 4.11 Reversing Valve 4 .12 Capillary Tube Model 4.12 CHAPTER PAGE Coding of Changes 4.16 Subcooler 4.17 Water Spray 4.17 Roughened Tubes 4.18 Reversing Valve 4.18 Capillary Tube 4.18 References 4.19 5 MODEL...

  11. Development of a room air conditioner design model 

    E-Print Network [OSTI]

    Penson, Steven Brad

    1988-01-01T23:59:59.000Z

    model was developed for this thesis by making major modifications to a heat pump model previously developed by Oak Ridge National Laboratory: (1) Addition of a subcooler, (2) Revision of the capillary tube model, (3) Addition of multi-grooved tubes.... Efficiency improvements are evaluated with the aid of a computer model. The model chosen for this analysis was the Oak Ridge National Laboratory (ORNL) heat pump model [5] . The ORNL Heat Pump Design Model is a FORTRAN computer program developed...

  12. Variable Speed Fan Retrofits for Computer Room Air Conditioners |

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilA group current C3EDepartmentDepartment of Energy Photo of a vapor

  13. List of Room Air Conditioners Incentives | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf KilaueaInformation Other Alternative FuelEnergy Jump to:List

  14. Variable Speed Fan Retrofits for Computer Room Air Conditioners

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your DensityEnergy U.S.-China Electric Vehicle and03/02 TUEValidation of Innovativeof Energy

  15. Variable Speed Fan Retrofits for Computer Room Air Conditioners |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your DensityEnergy U.S.-China Electric Vehicle and03/02 TUEValidation of Innovativeof EnergyDepartment of

  16. air conditioners electronic: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the issue of path planning is addressed for unmanned air vehicles (UAVs) cooperative joint-forces electronic attack operating in a hostile environment. Specifically, the...

  17. air conditioners: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of California eScholarship Repository Summary: chamber, passive sampling, passive solar house, measurementhouse, we planed the distribution of fresh air, passivepassive...

  18. Measure Guideline: Air Conditioner Diagnostics, Maintenance, and Replacement

    SciTech Connect (OSTI)

    Springer, D.; Dakin, B.

    2013-03-01T23:59:59.000Z

    This guideline responds to the need for an efficient means of identifying, diagnosing, and repairing faults in air conditioning systems in existing homes that are undergoing energy upgrades. Inadequate airflow due to constricted ducts or undersized filters, improper refrigerant charge, and other system defects can be corrected at a fraction of the cost of equipment replacement and can yield significant savings. The guideline presents a two-step approach to diagnostics and repair.

  19. Product Standards for Air Conditioners (Japan) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation,Pillar Group BV Jump to: navigation,Power RentalAreas-|LogPrincipleProblemsAir

  20. List of Central Air conditioners Incentives | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf Kilauea Volcano,LakefrontLighthouse SolarI JumpListBoilersListCeilingAir

  1. Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench 

    E-Print Network [OSTI]

    Palani, M.; O'Neal, D. L.; Haberl, J. S.

    1992-01-01T23:59:59.000Z

    constituted 17.2% of the total failure. The failure rates of compressors was 13.5% and outdoor fans was about 11.5%. Lewis surveyed 492 large HVAC dealers to compile information on heat pump service life [5]. He discovered that refrigerant leaks were the major... valve increases. PREDICTION OF DEGRADED CONDITIONS There are several steady state simulation programs which are available to predict the design conditions of air conditioners and heat pumps [20, 21]. The ORNL and NIST models are popular and extensively...

  2. 2014-05-05 Issuance: Test Procedure for Portable Air Conditioners; Notice of Data Availability

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register notice of data availabilty regarding test procedures for portable air conditioners, as issued by the Deputy Assistant Secretary for Energy Efficiency on May 5, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

  3. Energy Impacts of Oversized Residential Air Conditioners -- Simulation Study of Retrofit Sequence Impacts

    SciTech Connect (OSTI)

    Booten, C.; Christensen, C.; Winkler, J.

    2014-11-01T23:59:59.000Z

    This research addresses the question of what are the energy consequences for oversizing of an air conditioner in a home. Conventional wisdom holds that oversizing the AC results in significant energy penalties. However, the reason for this was shown to be due to crankcase heaters and not due to cycling performance of the AC, and is only valid for a particular set of assumptions. Adding or removing individual characteristics, such as ducts or crankcase heaters, can have measurable impacts on energy use. However, with all other home characteristics held constant, oversizing the AC generally has a small effect on cooling energy use, even if the cycling performance of the unit is poor. The relevant aspects of air conditioner modeling are discussed to illustrate the effects of the cycling loss coefficient, Cd, capacity, climate, ducts and parasitic losses such as crankcase heaters. A case study of a typical 1960's vintage home demonstrates results in the context of whole building simulations using EnergyPlus.

  4. Effects of Air Conditioner Use on Real-World Fuel Economy

    SciTech Connect (OSTI)

    Huff, Shean P [ORNL; West, Brian H [ORNL; Thomas, John F [ORNL

    2013-01-01T23:59:59.000Z

    Vehicle data were acquired on-road and on a chassis dynamometer to assess fuel consumption under several steady cruise conditions and at idle. Data were gathered for various air conditioner (A/C) settings and with the A/C off and the windows open. Two vehicles were used in the comparisonstudy: a 2009 Ford Explorer and a 2009 Toyota Corolla. At steady speeds between 64.4 and 112.7 kph (40 and 70 mph), both vehicles consumed more fuel with the A/C on at maximum cooling load (compressor at 100% duty cycle) than when driving with the windows down. The Explorer maintained this trend beyond 112.7 kph (70 mph), while the Corolla fuel consumption with the windows down matched that of running the A/C at 120.7 kph (75 mph), and exceeded it at 128.7 kph (80 mph). The largest incremental fuel consumption rate penalty due to air conditioner use occurred was nearly constant with a weakslight trend of increasing consumption with increasing compressor (and vehicle) speed. Lower consumption is seenobserved at idle for both vehicles, likely due to the low compressor speed at this operating point

  5. Energy savings and economics of advanced control strategies for packaged air conditioners with gas heat

    SciTech Connect (OSTI)

    Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

    2013-10-01T23:59:59.000Z

    This paper presents an evaluation of the potential energy savings from adding advanced control to existing packaged air conditioners. Advanced control options include air-side economizer, multi-speed fan control, demand control ventilation and staged cooling. The energy and cost savings from the different control strategies individually and in combination are estimated using the EnergyPlus detailed energy simulation program for four building types, namely, a small office building, a stand-alone retail building, a strip mall building and a supermarket building. For each of the four building types, the simulation was run for 16 locations covering all 15 climate zones in the U.S. The maximum installed cost of a replacement controller that provides acceptable payback periods to owners is estimated.

  6. EA-1892: Direct Final Rule Energy Conservation Standards for Residential Furnaces and Residential Central Air Conditioners & Heat Pumps

    Broader source: Energy.gov [DOE]

    This EA evaluates the environmental impacts of a proposal to adopt energy conservation standards for various consumer products and certain commercial and industrial equipment, including residential furnaces and residential air conditioners and heat pumps, as required by the Energy Policy and Conservation Act, as amended (42 U.S.C. 6291 et seq.)

  7. Modeling of a second-generation solar-driven Rankine air conditioner. Final report

    SciTech Connect (OSTI)

    Denius, M.W.; Batton, W.D.

    1984-07-01T23:59:59.000Z

    Ten configurations of a second-generation (2G), solar-powered, Rankine-driven air conditioner were simulated and the data presented for use in companion studies. The results of the analysis show that the boiling-in-collector (BIC) configuration generates more power per collector area than the other configurations. The models used to simulate the configuration are presented in this report. The generated data are also presented. Experimental work was done under this study to both improve a novel refrigerant and oil lubrication system for the centrifugal compressor and investigate the aerodynamic unloading characteristics of the centrifugal compressor. The information generated was used to define possible turbo-gearbox configurations for use in the second generation computer simulation.

  8. Life-cycle cost and payback period analysis for commercial unitary air conditioners

    SciTech Connect (OSTI)

    Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

    2004-03-31T23:59:59.000Z

    This report describes an analysis of the economic impacts of possible energy efficiency standards for commercial unitary air conditioners and heat pumps on individual customers in terms of two metrics: life-cycle cost (LCC) and payback period (PBP). For each of the two equipment classes considered, the 11.5 EER provides the largest mean LCC savings. The results show how the savings vary among customers facing different electricity prices and other conditions. At 11.5 EER, at least 80% of the users achieve a positive LCC savings. At 12.0 EER, the maximum efficiency analyzed, mean LCC savings are lower but still positive. For the {ge} $65,000 Btu/h to <135,000 Btu/h equipment class, 59% of users achieve a positive LCC savings. For the $135,000 Btu/h to <240,000 Btu/h equipment class, 91% of users achieve a positive LCC savings.

  9. Room air monitor for radioactive aerosols

    DOE Patents [OSTI]

    Balmer, David K. (Broomfield, CO); Tyree, William H. (Boulder, CO)

    1989-04-11T23:59:59.000Z

    A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-pre The U.S. Government has rights in this invention pursuant to Contract No. DE-AC04-76DP03533 between the Department of Energy and Rockwell International Corporation.

  10. Room air monitor for radioactive aerosols

    DOE Patents [OSTI]

    Balmer, D.K.; Tyree, W.H.

    1987-03-23T23:59:59.000Z

    A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-preamplifier combination. 2 figs.

  11. 2014-03-06 Issuance: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps; Notice of Proposed Rulemaking

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register notice of proposed rulemaking regarding test procedures for packaged terminal air conditioners and packaged terminal heat pumps, as issued by the Deputy Assistant Secretary on March 6, 2014.

  12. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    E-Print Network [OSTI]

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-01-01T23:59:59.000Z

    Central Air Conditioners and Heat Pumps Energy ConservationW.R. Coleman. 1990. “Heat Pump Life and Compressor LongevityC.C.. 1990. “Predicting Future Heat Pump Production Volume

  13. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    SciTech Connect (OSTI)

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-10-10T23:59:59.000Z

    In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER.

  14. Modeled and measured effects of compressor downsizing in an existing air conditioner/heat pump in the cooling mode

    SciTech Connect (OSTI)

    Levins, W.P.; Rice, C.K.; Baxter, V.D.

    1996-05-01T23:59:59.000Z

    It is not uncommon to find oversized central air conditioners in residences. HVAC contractors sometimes oversize central air conditioners for one reason or another--some to the point that they may be 100% larger than needed to meet the load. Retrofit measures done to improve house envelope and distribution system efficiency also contribute to HVAC oversizing, as they reduce house heating and cooling loads. Proper sizing of an air conditioner or heat pump allows more efficient operation and provides a more comfortable environment than a highly oversized unit. Another factor that lowers operating efficiency is an improper refrigerant charge. Field inspections have revealed that about half of the units checked were not properly charged. An option available to homeowners with oversized air conditioners is to replace the existing compressor with a smaller, more efficient compressor, rather than purchasing a new, smaller unit. Such a retrofit may be economically justified, especially during a compressor failure, provided the oversizing of the existing unit is not too great. A used, 15-year old, single-package heat pump with a capillary tube expansion device on the indoor coil was purchased and tested in a set of environmental chambers to determine its cooling performance at various conditions. The system was also modeled to estimate its existing performance, and that with two different types of retrofitted state-of-the-art (SOA) efficient compressors with about 30% less capacity than the original compressor. This reduced the overall system cooling capacity by about 25%. Modeling estimated that the retrofit would increase system EER at 95 F by 30%, SEER by 34%, and reduce power demand by 39% compared to the existing unit. Reduced cycling losses account for the higher increase in SEER.

  15. An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve

    E-Print Network [OSTI]

    Farzad, M.; O'Neal, D. L.

    1989-01-01T23:59:59.000Z

    by the manufacturer for a specific indoor and outdoor temperatures. Once the full charge was determined, the unit was subjected to 40%, 30%, 20%, 15%, 10%, and 5% undercharging and 5%, 10%, 15%, and 20% overcharging of refrigerant by mass. The fully charged tests were... CONDITION All tests were performed on a split system central air conditioner provided by the Trane company. To determine the proper amount of refrigerant charge needed in the system and the unit's corresponding performance, charging specifications...

  16. Field Test of Room-to-Room Distribution of Outside Air with Two Residential Ventilation Systems

    SciTech Connect (OSTI)

    Hendron, R.; Anderson, R.; Barley, D.; Rudd, A.; Townsend, A.; Hancock, E.

    2008-08-01T23:59:59.000Z

    Uniform distribution of outside air is one way to ensure that residential dilution ventilation systems will provide a known amount of fresh air to all rooms.

  17. Performance characteristics of a turbo expander substituted for expansion valve on air-conditioner

    SciTech Connect (OSTI)

    Cho, Soo-Yong [Department of Mechanical and Aerospace Engineering (ReCAPT), Gyeongsang National University, 900 Gajoa-dong, Jinju 660-701 (Korea); Cho, Chong-Hyun [School of Mechanical and Aerospace Engineering, Gyeongsang National University, 900 Gajoa-dong, Jinju 660-701 (Korea); Kim, Chaesil [Department of Mechanical Engineering, Changwon National University, 9 Sarim-dong, Changwon 641-773 (Korea)

    2008-09-15T23:59:59.000Z

    An experimental study is conducted on a small turbo expander which could be applied to the expansion process in place of expansion valves in refrigerator or air-conditioner to improve the cycle efficiency by recovering energy from the throttling process. The operating gas is HFC134a and the maximum cooling capacity of experiment apparatus is 32.7 kW. Four different turbo expanders are tested to find the performance characteristics of the turbo expander when they operate at a low partial admission rate. The partial admission rate is 1.70% or 2.37, and expanders are operated in the supersonic flow. In the experiment, pressure and temperature are measured at 10 different locations in the experimental apparatus. In addition to these measurements, output power at the turbo expander is measured through a generator installed on a rotor shaft with the rotational speed. Performance data of the turbo expander are obtained at many part load operations by adjusting the output power of the generator. A maximum of 15.8% total-to-static efficiency is obtained when the pressure ratio and the partial admission ratio are 2.37 and 1.70%, respectively. Experimental results show that the optimal velocity ratio decreases when the pressure ratio is decreased, and peak efficiencies, which are obtained at locally maximized efficiency depending on the operating condition, vary linearly against the subcooling temperature or the pressure ratio. (author)

  18. air-conditioners furnaces air: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of California eScholarship Repository Summary: chamber, passive sampling, passive solar house, measurementhouse, we planed the distribution of fresh air, passivepassive...

  19. The Effect of Reduced Evaporator Air Flow on the Performance of a Residential Central Air Conditioner 

    E-Print Network [OSTI]

    Palani, M.; O'Neal, D.; Haberl, J.

    1992-01-01T23:59:59.000Z

    surveyed 492 large HVAC dealers to compile information on heat pump service life [5]. He discovered that refrigerant leaks were the major cause for failure, totaling 19% of failed units. Compressor motor circuits and mechanical part failures were 16... Lewis, J. E.; 1987. "Survey of residential air-to-air heat pump service life and maintenance issues", ASHRAE Transactions, Vol. 93, Part 2, p. p. I II I - 1127. [6J Silver, T.; 1989. "Training for the Future", Contracting Business, December 1989, p...

  20. Development of Temperature and Humidity-Based Indicators for Diagnosing Problems in Low Tonnage, Split System Air Conditioners

    E-Print Network [OSTI]

    Watt, J. B.; O'Neal, D. L.; Haberl, J. S.

    1998-01-01T23:59:59.000Z

    of meeting a given cooling load; and equipment safety, or the ability to maintain equipment longevity by avoiding equipment-life-reducing conditions such as compressor slugging (no superheat) or lack of compressor cooling (high superheat) or seal...DEVELOPMENT OF TEMPERATURE AND HUMIDITY-BASED INDICATORS FOR DIAGNOSING PROBLEMS IN LOW TONNAGE, SPLIT SYSTEM AIR CONDITIONERS Jim Watt Jeff Haberl, P.E., PhD. Dennis O'Neai, P.E., PhD. CES/Way International, Inc. Energy Systems Laboratory Energy...

  1. An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with Capillary Tube Expansion

    E-Print Network [OSTI]

    Farzad, M.; O'Neal, D. L.

    1988-01-01T23:59:59.000Z

    of the coil was 20.94 ft2 with refrigerant tube sizes of 3/8". The outdoor fan was located on the top of the outdoor coil. The fan specifications are given in Table 3.1. Figure 3.3 - Detail of Outdoor Test Section 25 Table 3.1 - Fan Specification...ESL-TR-88/07-01 AN EVALUATION OF IMPROPER REFRIGERANT CHARGE ON THE PERFORMANCE OF A SPLIT SYSTEM AIR CONDITIONER WITH CAPILLARY TUBE EXPANSION FINAL REPORT Submitted by Mohsen Farzad Dennis L. O'Neal Prepared For ENERGY SYSTEMS LABORATORY RESEARCH...

  2. Experimental analysis of a window air conditioner with a R-22 and R32/R125/R134a mixture

    SciTech Connect (OSTI)

    Mei, V.C.; Chen, F.C.; Chen, D.T. [Oak Ridge National Lab., TN (United States); HuangFu, E.P. [USDOE, Washington, DC (United States)

    1995-07-01T23:59:59.000Z

    Much experimental and theoretical analysis of potential R-22 replacements has been accomplished. However, published information about the experimental analysis of any off-the-shelf air conditioner with a potential R-22 replacement at realistic, operating conditions is still rare. This type of work could be useful because it provides baseline data for comparing the performance of R-22 and its potential replacement at drop-in conditions. In this study, an off-the-shelf window air conditioner was tested at Air Conditioning and Refrigeration Institute (ARI)-rated indoor conditions and at different ambient temperatures, including the ARI-rated outdoor condition, with R-22 and with its potential replacement, a ternary mixture of R-32(30%)/R-125(10%)/R-134a(60%) (the ternary mixture). A test rig was built that provided for baseline operation and for the option of operating the system with a flooded evaporator by means of liquid over-feeding (LOF). The test results indicated the cooling capacity of the ternary mixture was 7.7% less than that of R-22 at 95{degrees}F ambient for baseline operation. The cooling capacity for both refrigerants improved when a flooded evaporator, or LOF, was used. For LOF operation, the cooling capacity of the ternary mixture was only 1.1% less than that of R-22. The ternary mixture had slightly higher compressor discharge pressure, a lower compressor discharge temperature, slightly lower compressor power consumption, and a higher compressor high/low pressure ratio.

  3. The Explorationon the Energy Saving Potential of an Innovative Dual-temperature Air Conditioner and the Mechanism of the Theoretical Mixed Refrigeration Cycl

    E-Print Network [OSTI]

    Zhao,L.; Zhao,X.; Hu,A.

    2014-01-01T23:59:59.000Z

    The Exploration on the Energy Saving Potential of an Innovative Dual-temperature Air Conditioner and the Mechanism of the Theoretical Mixed Refrigeration Cycle Zhao Lei, Zhao Xijin, Hu Andu Professor, graduate student, graduate student...-temperature air conditioning system and its corresponding theoretical mixed refrigeration cycle are proposed. This consists of a separate air handling unit and a metal radiation panel as the dual-temperature evaporators, a compressor, a condenser, two thermal...

  4. Prediction of Room Air Diffusion for Reduced Diffuser Flow Rates 

    E-Print Network [OSTI]

    Gangisetti, Kavita

    2011-02-22T23:59:59.000Z

    and analytical tool for investigating ventilation inside the system and thus to increase thermal comfort and improve indoor air quality. The room air supply diffuser flow rates can be reduced for less loading with the help of a variable air volume unit...

  5. An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve 

    E-Print Network [OSTI]

    Farzad, M.; O'Neal, D. L.

    1989-01-01T23:59:59.000Z

    and was exhausted by the unit fan back into the room through the outdoor coil. PSYCHROMETRIC ROOMS The psychrometric rooms could simulate all testing conditions required for air conditioning and heat pump performance testing. Dew point and room temperatures could..., Including Heat Pumps (1979)[7]. The entering dry bulb temperature for the outdoor coil for steady state and cyclic tests was 82? +/-0.3 F DB and 20% relative humidity. The steady state tests were repeated for outdoor temperatures of 90?, 95?, and 100?F...

  6. Improving Best Air Conditioner Efficiency by 20-30% through a High Efficiency Fan and Diffuser Stage Coupled with an Evaporative Condenser Pre-Cooler

    SciTech Connect (OSTI)

    Parker, Danny S; Sherwin, John R; Raustad, Richard

    2014-04-10T23:59:59.000Z

    The Florida Solar Energy Center (FSEC) conducted a research project to improve the best residential air conditioner condenser technology currently available on the market by retrofitting a commercially-available unit with both a high efficiency fan system and an evaporative pre-cooler. The objective was to integrate these two concepts to achieve an ultra-efficient residential air conditioner design. The project produced a working prototype that was 30% more efficient compared to the best currently-available technologies; the peak the energy efficiency ratio (EER) was improved by 41%. Efficiency at the Air-Conditioning and Refrigeration Institute (ARI) standard B-condition which is used to estimate seasonal energy efficiency ratio (SEER), was raised from a nominal 21 Btu/Wh to 32 Btu/Wh.

  7. Prediction of Room Air Diffusion for Reduced Diffuser Flow Rates

    E-Print Network [OSTI]

    Gangisetti, Kavita

    2011-02-22T23:59:59.000Z

    With the ever-increasing availability of high performance computing facilities, numerical simulation through Computational Fluid Dynamics (CFD) is increasingly used to predict the room air distribution. CFD is becoming an important design...

  8. Cornell's (LSC) project began providing 16,000 tons of cooling (1 ton of cooling = 12,000 Btu/hr, or approximately one large residential window air conditioner) to Cornell University's Ithaca

    E-Print Network [OSTI]

    Keinan, Alon

    window air conditioner) to Cornell University's Ithaca campus in July of 2000. This project has almost completely replaced mechanical refrigeration for the Cornell district cooling system with the following benefits: · Greater LSC has replaced

  9. Modeling the effects of Refrigerant Charging on Air Conditioner Performance Characteristics For Three Expansion Devices 

    E-Print Network [OSTI]

    Farzad, Mohsen

    1990-01-01T23:59:59.000Z

    a small refrigerant charge. A new heat exchanger model based on tube-by-tube simulation was developed and integrated into the ORNL heat pump model. The model was capable of simulating the steady state response of a vapor compression air-to-air heat...

  10. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    L ABORATORY China Energy Efficiency Round Robin TestingNeed to Improve the Energy Efficiency of Energy Consumingfor Implementing the China Energy Efficiency Label System (

  11. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01T23:59:59.000Z

    its integration. In the DOE’s energy model which was used toSources The energy efficiency simulation model used in thiss Bottom Up Energy Analysis System (BUENAS) model (McNeil et

  12. Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners

    E-Print Network [OSTI]

    McNeil, Michael A.; Iyer, Maithili

    2008-01-01T23:59:59.000Z

    the current cost of production of 3.5 Rs per kWh. It isthe average cost of production to be 3.50 Rs. per kWh, or $the cost of production significantly at 4.80 Rs. per kWh. As

  13. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    further passed the Energy Efficiency (Labeling of Products)L ABORATORY China Energy Efficiency Round Robin TestingNeed to Improve the Energy Efficiency of Energy Consuming

  14. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    Flow Chart of Sample Selection Process Appoint manufactures to choose the samples (4 sets) Sample energy

  15. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01T23:59:59.000Z

    Renewable Energy Laboratory, Facility of the U.S. Department of Energy ODP Ozone depletion potential

  16. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    China Energy Efficiency Label System (CEELS) In order to improve the energy efficiency of main energy consuming products, the gov-

  17. Five ENERGY STAR Room Air Conditioners Fail Testing | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport inEnergy June 6-7, 2013 MeetingEA #FebruaryFisker, Tesla, and American

  18. Investigations on Vapour Compression Air Conditioner with Direct Contact Desiccant Loop over Condenser and Evaporator

    E-Print Network [OSTI]

    Maiya, M. P.; Ravi, J.; Tiwari, S.

    2010-01-01T23:59:59.000Z

    Perceived air quality increases when relative humidity is decreased till about 30% in the range of comfort temperature. In the present scenario, humidity is considered as a pollutant. Hence, a controlled environment not only at low temperature...

  19. Testing and Economic Evaluation of a High Efficiency 10-ton Rooftop Air Conditioner

    E-Print Network [OSTI]

    O'Neal, D. L.; Davis, M. A.

    2006-11-09T23:59:59.000Z

    In 1993, the U.S. Environmental Protection Agency initiated a project to design, build and demonstrate a high efficiency commercial rooftop air conditioning unit. The unit was designed by Hibberd Consulting of Westminster, Colorado, and was built...

  20. Fault detection methods for vapor-compression air conditioners using electrical measurements

    E-Print Network [OSTI]

    Laughman, Christopher Reed.

    2008-01-01T23:59:59.000Z

    (cont.) This method was experimentally tested and validated on a commercially available air handler and duct system. In the second class of faults studied, liquid refrigerant, rather than vapor, enters the cylinder of a ...

  1. An Investigation of Alternative Methods for Measuring Static Pressure of Unitary Air Conditioners and Heat Pumps

    E-Print Network [OSTI]

    Wheeler, Grant Benson

    2013-08-12T23:59:59.000Z

    This project was created to address an important issue currently faced by test facilities measuring static pressure for air-conditioning and heat pumps. Specifically, ASHRAE Standard 37, the industry standard for test setup, requires an outlet duct...

  2. Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench

    E-Print Network [OSTI]

    Palani, M.; O'Neal, D. L.; Haberl, J. S.

    1992-01-01T23:59:59.000Z

    enthalpies at six locations were calculated using the refrigerant property calculation program developed by Kartsounes[26]. Air-side enthalpy, humidity and specific volume were calculated by a psychrometric program developed at the Energy Systems Laboratory... procedure based on measurement of refrigerant and air side temperatures. n TABLE OF CONTENTS CHAPTER Page I INTRODUCTION 1 E LITERATURE REVIEW 3 Service and failure patterns 3 Degradation studies 4 HI MODEL DEVELOPMENT 6 Theory of operation 6 Degraded...

  3. Dirty Air Conditioners: Energy Implications of Coil Fouling Jeffrey Siegel, Lawrence Berkeley National Laboratory/ UC Berkeley

    E-Print Network [OSTI]

    Siegel, Jeffrey

    . For typical residential heat pump and air conditioning Residential Buildings: Technologies, Design heat pump condenser coil will foul sufficiently to cause a 20 % reduction in performance over a 4 to 7 is based on a model of heat exchanger fouling that we developed specifically for residential heat

  4. Dirty Air Conditioners: Energy Implications of Coil Fouling Jeffrey Siegel, Lawrence Berkeley National Laboratory/ UC Berkeley

    E-Print Network [OSTI]

    . For typical residential heat pump and air conditioning #12;systems, they predict a 10 ­ 25 % average energy heat pump condenser coil will foul sufficiently to cause a 20 % reduction in performance over a 4 to 7 is based on a model of heat exchanger fouling that we developed specifically for residential heat

  5. Improving the Operating Efficiency of Packaged Air Conditioners and Heat Pumps

    SciTech Connect (OSTI)

    Katipamula, Srinivas; Wang, Weimin; Vowles, Mira

    2014-03-10T23:59:59.000Z

    This article discusses several control strategies that can significantly reduce energy consumption associated with packaged rooftop units RTUs). Although all of the considered strategies are widely used in built-up air-handing units, they are not commonly used in existing RTUs. Both simulation and field evaluations show that adding these control strategies to existing RTUs can reduce their energy consumption by between 30% and 60%.

  6. The Impact of Residential Air Conditioner Charging and Sizing on Peak Electrical Demand

    E-Print Network [OSTI]

    Neal, L.; O'Neal, D. L.

    rebate and maintenance programs for many years. The purpose of these programs was to improve the efficiency of the stock of air conditioning equipment and provide better demand-side management. This paper examines the effect of refrigerant charging... increases. The cooling load is assumed to be zero at an outdoor temperature of 70 F. This would assume an internal heat gain equal to approximately 8 F if the thermostat setting is at 78 F. The house load is also assumed to be equal to the test unit...

  7. ISSUANCE 2015-05-01: Commercial Package Air Conditioners and Commercial

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy ChinaofSchaefer To:Department ofOralGovernment VehicleStandards forCommittee:Warm Air

  8. Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study

    SciTech Connect (OSTI)

    Piotr A. Domanski; W. Vance Payne

    2002-10-31T23:59:59.000Z

    The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

  9. Analysis on the energy efficiency of variable-frequency air conditioners (Hitachi models as an example) Jim Jr-Min Lin 2014.09.26

    E-Print Network [OSTI]

    Analysis on the energy efficiency of variable-frequency air conditioners (Hitachi models (Max) Energy Efficiency @min load Energy Efficiency @Max load kW kW kW kW W/W W/W RAS-22NB 1.00 3.20 0 Efficiency @min load Energy Efficiency @Max load kW kW kW kW W/W W/W RAM-5FNS(B) - 12.5 - 2.91 - 4.3 RAM-6FNS

  10. 2015-02-13 Issuance: Energy Conservation Standards for Portable Air Conditioners; Notice of Public Meeting and Availability of the Preliminary Technical Support Document

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register notice of public meeting regarding energy conservation standards for portable air conditioners, as issued by the Deputy Assistant Secretary for Energy Efficiency on February 13, 2015. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

  11. A Novel, Low-Cost, Reduced-Sensor Approach for Providing Smart Renote Monitoring and Diagnostics for Packaged Air Conditioners and Heat Pumps

    SciTech Connect (OSTI)

    Brambley, Michael R.

    2009-09-01T23:59:59.000Z

    This report describes conceptually an approach to providing automated remote performance and conditioning monitoring and fault detection for air conditioners and heat pumps that shows great promise to reduce the capital and installation costs of such systems from over $1000 per unit to $200 to $400 per unit. The approach relies on non-intrusive electric load monitoring (NIELM) to enable separation of the power use signals of compressors and fans in the air conditioner or heat pump. Then combining information on the power uses and one or two air temperature measurements, changes in energy efficiency and occurrence of major faults would be detected. By decreasing the number of sensors used from between ten and twenty in current diagnostic monitoring systems to three for the envisaged system, the capital cost of the monitoring system hardware and the cost of labor for installation would be decreased significantly. After describing the problem being addressed and the concept for performance monitoring and fault detection in more detail, the report identifies specific conditions and faults that the proposed method would detect, discusses specific needs for successful use of the NIELM approach, and identifies the major elements in the path from concept to a commercialized monitoring and diagnostic system.

  12. Proceedings of Healthy Buildings 2009 Paper 474 Impacts of HVAC Filtration on Air-Conditioner Energy Consumption in

    E-Print Network [OSTI]

    Siegel, Jeffrey

    -Conditioner Energy Consumption in Residences Brent Stephens1,* , Atila Novoselac1 and Jeffrey A. Siegel1 1, a greater pressure drop will generally lead to increased energy consumption (e.g., Fisk et al., 2002 The University of Texas at Austin, USA * Corresponding email: stephens.brent@mail.utexas.edu SUMMARY The use

  13. Control of Computer Room Air Conditioning using IT Equipment Sensors

    SciTech Connect (OSTI)

    Bell, Geoffrey C.; Storey, Bill; Patterson, Michael K.

    2009-09-30T23:59:59.000Z

    The goal of this demonstration was to show how sensors in IT equipment could be accessed and used to directly control computer room air conditioning. The data provided from the sensors is available on the IT network and the challenge for this project was to connect this information to the computer room air handler's control system. A control strategy was developed to enable separate control of the chilled water flow and the fans in the computer room air handlers. By using these existing sensors in the IT equipment, an additional control system is eliminated (or could be redundant) and optimal cooling can be provided saving significant energy. Using onboard server temperature sensors will yield significant energy reductions in data centers. Intel hosted the demonstration in its Santa Clara, CA data center. Intel collaborated with IBM, HP, Emerson, Wunderlich-Malec Engineers, FieldServer Technologies, and LBNL to install the necessary components and develop the new control scheme. LBNL also validated the results of the demonstration.

  14. Stability limit of room air temperature of a VAV system

    SciTech Connect (OSTI)

    Matsuba, Tadahiko; Kamimura, Kazuyuki [Yamatake-Honeywell Co., Ltd., Tokyo (Japan). Building System Div.; Kasahara, Masato; Kimbara, Akiomi; Kurosu, Shigeru [Oyama National Coll. of Technology (Japan); Murasawa, Itaru; Hashimoto, Yukihiko [Tonets Corp., Tokyo (Japan). Engineering Project Dept.

    1998-12-31T23:59:59.000Z

    To control heating, ventilating, and air-conditioning (HVAC) systems, it has been necessary to accept an analog system controlled mainly by proportional-plus-integral-plus-derivative (PID) action. However, when conventional PID controllers are replaced with new digital controllers by selecting the same PID parameters as before, the control loops have often got into hunting phenomena, which result in undamped oscillations. Unstable control characteristics (such as huntings) are thought to be one of the crucial problems faced by field operators. The PID parameters must be carefully selected to avoid instabilities. In this study, a room space is simulated as a thermal system that is air-conditioned by a variable-air-volume (VAV) control system. A dynamic room model without infiltration or exfiltration, which is directly connected to a simple air-handling unit without an economizer, is developed. To explore the possible existence of huntings, a numerical system model is formulated as a bilinear system with time-delayed feedback, and a parametric analysis of the stability limit is presented. Results are given showing the stability region affected by the selection of control and system parameters. This analysis was conducted to help us tune the PID controllers for optimal HVAC control.

  15. Distribution and Room Air Mixing Risks to Retrofitted Homes

    SciTech Connect (OSTI)

    Burdick, A.

    2014-12-01T23:59:59.000Z

    ?Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. For a single-story house with ceiling supply air diffusers, ducts are often removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling.

  16. Research on Thermal Properties in a Phase Change Wallboard Room Based on Air Conditioning Cold Storage

    E-Print Network [OSTI]

    Feng, G.; Li, W.; Chen, X.

    2006-01-01T23:59:59.000Z

    After comparing the thermal performance parameters of an ordinary wall room to a phase change wall (PCW) room, we learn that phase change wallboard affects the fluctuation of temperature in air-conditioning room in the summer. We built a PCW room...

  17. An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with Capillary Tube Expansion 

    E-Print Network [OSTI]

    Farzad, M.; O'Neal, D. L.

    1988-01-01T23:59:59.000Z

    ] conducted a laboratory test to determine the performance of a 3-ton air-to-air heat pump as a function of R-22 refrigerant charge in the heating mode. The tests were conducted with 50?F outdoor air and 70?F indoor air temperatures. The test unit did....8) 11 Figure 2.5 - Coefficient of Performance as a Function of Refrigerant Charge (adopted from ref.8) 12 A. A. Domingorena and S. J. Ball [9] studied the performance of a selected three-ton air-to-air heat pump in the heating mode at Oak Ridge...

  18. PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976

    E-Print Network [OSTI]

    Dao, K.

    2010-01-01T23:59:59.000Z

    from flat-plate solar collectors and use air cooling forwith flat-plate solar collectors and air cooling; namely,from flat-plate solar collectors. Absorption refrigeration

  19. Analysis of Energy Saving in a Clean Room Air-conditioning System

    E-Print Network [OSTI]

    Liu, S.; Liu, J.; Pei, J.; Wang, M.

    2006-01-01T23:59:59.000Z

    temperature field, small supply air temperature difference, large airflow, but no reheater. As the design airflow rate of air conditioning system for cleaning mainly considered to meet the need of the cleanliness class, its air exchange rate was much... above, we had chosen a representative air-handling unit for the testing renovation of 2nd return air system. Cleaning area for this AHU was a capsule clean room with a hundred thousand cleanliness classes. Indoor controlled dry-bulb temperature...

  20. Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control: Report and Summary Report

    SciTech Connect (OSTI)

    Dean, J.; Kozubal, E.; Herrmann, L.; Miller, J.; Lowenstein, A.; Barker, G.; Slayzak, S.

    2012-11-01T23:59:59.000Z

    The primary objective of this project was to demonstrate the capabilities of a new high-performance, liquid-desiccant dedicated outdoor air system (DOAS) to enhance cooling efficiency and comfort in humid climates while substantially reducing electric peak demand at Tyndall Air Force Base (AFB), which is 12 miles east of Panama City, Florida.

  1. Development of empirical temperature and humidity-based degraded-condition indicators for low-tonnage air conditioners

    E-Print Network [OSTI]

    Watt, James Bonner

    1997-01-01T23:59:59.000Z

    of conditions resulting in inefficient operation as reported by Neal from a survey of 10 residential air-conditioning units (Neal 1986, 1987). Problem Refri erant over-char e Refri erant under-char e Eva orator airflow inade uate Ev orator airflow too hi... wheel Freon char e Com onent Condition ratin Poor to Fair Poor to Fair Poor to Fair Return-air lenum Condensate s stem Su 1 air ducts Eva orator Coils Filter Controls Poor to Fair Poor to Avera e Fair to Avera e Fair to Good Fair to Good...

  2. Development of Temperature and Humidity-Based Indicators for Diagnosing Problems in Low Tonnage, Split System Air Conditioners 

    E-Print Network [OSTI]

    Watt, J. B.; O'Neal, D. L.; Haberl, J. S.

    1998-01-01T23:59:59.000Z

    and businesses. The unit had heat pump operation capability, however, the heat pump mode was not used in these tests. The entire assembly is shown in Figure 2. The evaporator section was connected to the condensing unit with copper tubing. The liquid... ): preprint. Lewis, J. 1987. Survey of residential air-to-air heat pump service life and maintenance issues. ASHRAE Transactions, 93( 1): 1 1 1 1 - 1 127. Lloyd, G.R., 1994. T.E.C.H. method lesson series. 27227 Weddel, Trenton, MI. McQuiston, F.C. and J...

  3. Analysis of Energy Saving in a Clean Room Air-conditioning System 

    E-Print Network [OSTI]

    Liu, S.; Liu, J.; Pei, J.; Wang, M.

    2006-01-01T23:59:59.000Z

    above, we had chosen a representative air-handling unit for the testing renovation of 2nd return air system. Cleaning area for this AHU was a capsule clean room with a hundred thousand cleanliness classes. Indoor controlled dry-bulb temperature...

  4. Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-02-01T23:59:59.000Z

    Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems - a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms - were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

  5. Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products

    E-Print Network [OSTI]

    Homan, GregoryK

    2010-01-01T23:59:59.000Z

    air cleaners Room air conditioners Scanners Servers Set-topBoilers • Central Air Conditioners and Air-Source HeatHeat Pump -Central Air Conditioner -Gas Furnace -Oil

  6. Effect of refrigerant charge, duct leakage, and evaporator air flow on the high temerature performance of air conditioners and heat pumps

    E-Print Network [OSTI]

    Rodriguez, Angel Gerardo

    1995-01-01T23:59:59.000Z

    evaporator airflow, and return air leakage from hot attic spaces. There were five sets of tests used for this research: two of them for the charging tests, two for the reduced evaporator airflow, and one for the return air leakage tests. For the charging...

  7. Framework for Coupling Room Air Models to Heat Balance Model Load and Energy Calculations (RP-1222)

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    1 Framework for Coupling Room Air Models to Heat Balance Model Load and Energy Calculations (RP in a program for hourly load calculations of a single thermal zone. The heat balance model for load and energy to heat balance model load and energy calculations," HVAC&R Research, 10(2), 91-111. #12;2 · Mixed

  8. 13 EER Window Air Conditioner

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: The Future of BadTHE U.S. DEPARTMENT OF ENERGY'EliseConferencePRESENTATIONSof13

  9. Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector

    E-Print Network [OSTI]

    McNeil, Michael A.; Letschert, Virginie E.

    2008-01-01T23:59:59.000Z

    an air conditioner for the first time, or by replacements ofair conditioner lifetime. Each retirement generates another replacementreplacements. Step 1 is described in detail in the section called Forecasting Air Conditioner

  10. Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector

    E-Print Network [OSTI]

    McNeil, Michael A.; Letschert, Virginie E.

    2008-01-01T23:59:59.000Z

    an air conditioner for the first time, or by replacements ofair conditioner lifetime. Each retirement generates another replacementand replacements. Step 1 is described in detail in the section called Forecasting Air Conditioner

  11. Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in China

    E-Print Network [OSTI]

    McNeil, Michael A.

    2012-01-01T23:59:59.000Z

    television and an air conditioner. In the future, ownershipresidential room air conditioners require the largesttelevision and an air conditioner. In the future, ownership

  12. Air-Con International: Noncompliance Determination and Proposed...

    Energy Savers [EERE]

    Notice of Noncompliance Determination to Air-Con International finding that a variety of central air conditioners and air conditioning heat pumps distributed under the Air-Con...

  13. Check-Testing of Manufacturer Self Reported Labeling Data & Compliance with MEPS

    E-Print Network [OSTI]

    Zhou, Nan

    2008-01-01T23:59:59.000Z

    2 Room Air-conditioner Air-conditioner Initial test- ing Re-HFS BJS BJS HFS BJS BJS Non- compliant* Air-conditioner9 Table 5. Room Air Conditioner 2000

  14. Airflow Simulation and Energy Analysis in Ventilated Room with a New Type of Air Conditioning

    E-Print Network [OSTI]

    Liu, D.; Tang, G.; Zhao, F.

    2006-01-01T23:59:59.000Z

    Airflow simulation in one ventilated room with radiant heating and natural ventilation has been carried out. Three cases are compared: the closed room, the room with full openings, and the room with small openings. The radiator heating room...

  15. How the Number and Placement of Sensors Controlling Room Air Distribution Systems Affect Energy Use and Comfort 

    E-Print Network [OSTI]

    Wang, D.; Arens, E.; Webster, T.; Shi, M.

    2002-01-01T23:59:59.000Z

    This study assesses the impact of sensor number and placement on the energy needed to condition a typical office using several likely variants of an underfloor air distribution system (UFAD). The study uses an empirical-based room stratification...

  16. Indoor Chemical Exposures: Humans' Non-respiratory Interactions with Room Air

    ScienceCinema (OSTI)

    Charles Weschler

    2010-09-01T23:59:59.000Z

    March 18, 2010 Berkeley Lab Environmental Energy Technology Division distinguished lecture: The marked difference in pollutant concentrations between an occupied and un-occupied room are only partially explained by human bio-effluents. Humans alter levels of ozone and related oxidants such as nitrate and hydroxyl radicals in the rooms they inhabit; in effect, they change the oxidative capacity of room air. Ozone-initiated reactions on exposed skin, hair and clothing generate products, including potentially irritating chemicals whose concentrations are much higher in the occupant's breathing zone than in the core of the room. Charles J. Weschler is a Professor at the School of Public Health, the Department of Environmental and Occupational Medicine and the Environmental and Occupational Health Sciences Institute (EOHSI) at the University of Medicine and Dentistry of New Jersey (UMDNJ)/Robert Wood Johnson Medical School & Rutgers University (New Jersey). He is also a Visiting Professor at the International Centre for Indoor Environment and Energy, Technical University of Denmark (DTU, Lyngby, Denmark).

  17. DOE Requires Air-Con International to Cease Sales of Inefficient...

    Broader source: Energy.gov (indexed) [DOE]

    Requires Air-Con International to Cease Sales of Inefficient Air Conditioners and Proposes Penalties DOE Requires Air-Con International to Cease Sales of Inefficient Air...

  18. Homeowner's Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet), Building America Case Study: Technology Solutions for Existing Homes, Building Technologies Office (BTO)

    SciTech Connect (OSTI)

    Not Available

    2013-06-01T23:59:59.000Z

    This fact sheet offers a step-by-step guide to proper installation of window air conditioning units, in order to improve efficiency and comfort for homeowners.

  19. Laser Sheet Light Flow Visualization For Evaluating Room Air Flows From

    E-Print Network [OSTI]

    ;Introduction Forced air heating and cooling systems and whole house ventilation systems deliver air

  20. How the Number and Placement of Sensors Controlling Room Air Distribution Systems Affect Energy Use and Comfort

    E-Print Network [OSTI]

    Wang, D.; Arens, E.; Webster, T.; Shi, M.

    2002-01-01T23:59:59.000Z

    , ISRACVE, ASHRAE, 1993 Li, Y., M. Sandberg, and L. Fuchs. ?Vertical temperature profiles in rooms ventilated by displacement: full-scale measurement and nodal modeling.? Indoor Air, 1992. Vol. 2, pp. 225-243. Linden, P.F., G.F. Lane-Serff,, and D...

  1. Importance of the Return Air Opening to Degree of Turbulence in a I-Grade Clean Operating Room

    E-Print Network [OSTI]

    Cheng, S.

    2006-01-01T23:59:59.000Z

    room in conditions that insure a degree of cleanliness and supply velocity. The size of the return air opening has been analyzed by comparing the results of the numerical simulation and experiment. The results will help the design of the I-grade clean...

  2. Room air stratification in combined chilled ceiling and displacement ventilation systems.

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2012-01-01T23:59:59.000Z

    Environments. Proceedings of Indoor Air 2005: 10 thInternational Conference on Indoor Air Quality and Climate,displacement ventilation hybrid air conditioning system-

  3. Global Potential of Energy Efficiency Standards and Labeling Programs

    E-Print Network [OSTI]

    McNeil, Michael A

    2008-01-01T23:59:59.000Z

    impact of room air conditioners energy labels in Malaysia."of electric Room Air Conditioner." Energy Economics 20Standard Levels for Room Air Conditioners. McNeil, M. A. ,

  4. Air Cooling Technology for Power Electronic Thermal Control

    Broader source: Energy.gov (indexed) [DOE]

    air conditioners Need to understand system trade-offs driven by air source local thermal environment which are influenced by inverter location National Renewable Energy Laboratory...

  5. TABLE OFCONTENTS Contract Information

    E-Print Network [OSTI]

    Polly, David

    ....................................... 3 Your Room Assignments .......................................................... 4 Air Conditioner ................................................... 4 Consolidation ......................................................... 4 Heating &Air

  6. Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1

    E-Print Network [OSTI]

    Johnson, F.X.

    2010-01-01T23:59:59.000Z

    A H A M . 1991. Room Air Conditioner Data. Association of7. FUTURE WORK 7.1 Room Air Conditioners 7.2. Common heatingShipments of Unitary Air Conditioners and Heat Pumps. Air-

  7. Using National Survey Data to Estimate Lifetimes of Residential Appliances

    E-Print Network [OSTI]

    Lutz, James D.

    2013-01-01T23:59:59.000Z

    furnaces, boilers, water heaters, room air-conditioners,furnaces, boilers, water heaters, room air-conditioners (and Electric Storage Water Heaters Table 6 and 7 show the

  8. Room Temperature Control During Season Switchover with Single Duct Variable Air Volume System Without Reheat 

    E-Print Network [OSTI]

    Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D.; Bruner, H.

    2003-01-01T23:59:59.000Z

    The Langford “A” building houses the College of Architecture on TAMU campus. There are ten singleduct variable air volume (VAV) air-handling units (AHUs) without reheat serving the building. The local pneumatic thermostats modulate the dampers...

  9. Arnold Schwarzenegger Preserving California's

    E-Print Network [OSTI]

    ....................................................112 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods..........51 B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps.......81 B-3 Standards for Packaged Terminal Air Conditioners and Packaged Terminal Heat

  10. Table Contents Page i 2013 Nonresidential Compliance Manual January 2014

    E-Print Network [OSTI]

    Table B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner ....................................................................................11 Table B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps...........12 Table B-3 Standards for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps

  11. EVALUATION OF A NEW SOLAR AIR CONDITIONER

    E-Print Network [OSTI]

    · Benefits to California · Overall Technology Assessment · Appendices o Appendix A: Final Report (under-16 Grant Funding: $74,547 Term: February 2001 ­ June 2003 PIER Subject Area: Renewable Energy Technologies/Agricultural/Water End-Use Energy Efficiency · Renewable Energy Technologies · Environmentally-Preferred Advanced

  12. Natural Gas Heat Pump and Air Conditioner

    Broader source: Energy.gov [DOE]

    Lead Performer: Thermolift - Stony Brook, NY Partners: -- New York State Energy Research & Development Authority - Albany, NY -- Stony Brook University - Stony Brook, NY -- Oak Ridge National Laboratory - Oak Ridge, TN -- National Grid - Washington, DC -- Applied Thermodynamic Apparatus (ATA) - Ann Arbor, MI -- Fala Technologies - Kingston, NY -- LoDolce - Saugerties, NY

  13. Common Air Conditioner Problems | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube platformBuildingCoal CombustionSmart Gridfor Federal Facilities

  14. Common Air Conditioner Problems | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625govInstrumentstdmadapInactiveVisiting theCommercialization and Innovation The Commercialization andCommittees

  15. Central Air conditioners | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model, click here.Telluric Survey asWest, NewCenterville, Ohio: Energy

  16. Tips: Air Conditioners | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you sure you want toworldPower 2010 1 TNews & Solar Solar How

  17. Maintaining Your Air Conditioner | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122Commercial602 1,39732on ArmedManufacturingJunePracticeShipping GoalMailDepartment

  18. Cromer Cycle Air Conditioner | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"Wave theJuly 30,Crafty Gifts for theof EnergyRev. 1) |

  19. DOE Investigates Possible Air Conditioner Efficiency Violations |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"Wave theJulyD&DDepartment of Energy IdentifiesforDepartment

  20. Maintaining Your Air Conditioner | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking ofOil & Gas »ofMarketing |PrepareMOJAVE

  1. Tips: Air Conditioners | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMayDepartmentTest for PumpingThe| Department of

  2. Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector

    E-Print Network [OSTI]

    McNeil, Michael A.; Letschert, Virginie E.

    2008-01-01T23:59:59.000Z

    G. Henderson (2005) Home air conditioning in Europe – howhigher growth in Indian air conditioner saturation duringand A.A. Pavlova ( 2003). Air conditioning market saturation

  3. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens

    SciTech Connect (OSTI)

    Not Available

    1993-11-01T23:59:59.000Z

    This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

  4. Low-noise pulse conditioner

    DOE Patents [OSTI]

    Bird, David A. (Oak Ridge, TN)

    1983-01-01T23:59:59.000Z

    A low-noise pulse conditioner is provided for driving electronic digital processing circuitry directly from differentially induced input pulses. The circuit uses a unique differential-to-peak detector circuit to generate a dynamic reference signal proportional to the input peak voltage. The input pulses are compared with the reference signal in an input network which operates in full differential mode with only a passive input filter. This reduces the introduction of circuit-induced noise, or jitter, generated in ground referenced input elements normally used in pulse conditioning circuits, especially speed transducer processing circuits.

  5. Room air stratification in combined chilled ceiling and displacement ventilation systems.

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2012-01-01T23:59:59.000Z

    nodal model for displacement ventilation and chilled ceiling2002. Displacement ventilation in non- industrial premises.ceiling/displacement ventilation hybrid air conditioning

  6. Energy Consumption, Efficiency, Conservation, and Greenhouse Gas Mitigation in Japan's Building Sector

    E-Print Network [OSTI]

    2006-01-01T23:59:59.000Z

    4.4.3 C o o l i n g Air Conditioner Multi-room Load AirGHPs) Chillers Air Conditioner COP Desiccant Conditioningappliances such as air-conditioners, refrigerators and

  7. HEATING, AIR-CONDITIONING AND REFRIGERATION DISTRIBUTORS INTERNATIONAL...

    Broader source: Energy.gov (indexed) [DOE]

    OE Framework Document and Stakeholder Meeting regarding the Enforcement of the updated Energy Conservation Standards for Air Conditioners, Furnaces and Heat Pumps. DOE EX Parte...

  8. Low-noise pulse conditioner

    DOE Patents [OSTI]

    Bird, D.A.

    1981-06-16T23:59:59.000Z

    A low-noise pulse conditioner is provided for driving electronic digital processing circuitry directly from differentially induced input pulses. The circuit uses a unique differential-to-peak detector circuit to generate a dynamic reference signal proportional to the input peak voltage. The input pulses are compared with the reference signal in an input network which operates in full differential mode with only a passive input filter. This reduces the introduction of circuit-induced noise, or jitter, generated in ground referenced input elements normally used in pulse conditioning circuits, especially speed transducer processing circuits. This circuit may be used for conditioning the sensor signal from the Fidler coil in a gas centrifuge for separation of isotopic gaseous mixtures.

  9. Development of slotted orifice flow conditioner

    E-Print Network [OSTI]

    Ihfe, Larry Michael

    1994-01-01T23:59:59.000Z

    for the two flow conditioners. A baseline Co was also plotted for comparative purposes. 24 RESULTS LDA Veloci Profile and Turbulence Intensi Anal sis The velocity profile and turbulence intensity measurements obtained using the LDA are shown in figures...

  10. Realized and Projected Impacts of U.S. Energy Efficiency Standards for Residential and Commercial Appliances

    E-Print Network [OSTI]

    Meyers, Stephen P.

    2008-01-01T23:59:59.000Z

    and Heat Pumps Room Air Conditioners Water Heaters Gas Furnaces Clothes Washers Clothes Dryers Dishwashers COMMERCIAL

  11. Metal-air cell comprising an electrolyte with a room temperature ionic liquid and hygroscopic additive

    DOE Patents [OSTI]

    Friesen, Cody A.; Krishnan, Ramkumar; Tang, Toni; Wolfe, Derek

    2014-08-19T23:59:59.000Z

    An electrochemical cell comprising an electrolyte comprising water and a hydrophobic ionic liquid comprising positive ions and negative ions. The electrochemical cell also includes an air electrode configured to absorb and reduce oxygen. A hydrophilic or hygroscopic additive modulates the hydrophobicity of the ionic liquid to maintain a concentration of the water in the electrolyte is between 0.001 mol % and 25 mol %.

  12. PowerPoint Presentation

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1990, 1993, 2001, 2014 NAECA 1987 Room Air Conditioners 1990, 2000, 2014 NAECA 1987 Central Air Conditioners and Heat Pumps 19921993, 2006, 2015 NAECA 1987 Water Heaters...

  13. Splashing phenomena of room temperature liquid metal droplet striking on the pool of the same liquid under ambient air environment

    E-Print Network [OSTI]

    Haiyan Li; Shengfu Mei; Lei Wang; Yunxia Gao; Jing Liu

    2013-09-04T23:59:59.000Z

    In this article, the fluid dynamics of room temperature liquid metal (RTLM) droplet impacting onto a pool of the same liquid in ambient air was investigated. A series of experiments were conducted in order to disclose the influence of the oxidation effect on the impact dynamics. The droplet shape and impact phenomenology were recorded with the aid of a high-speed digital camera. The impact energy stored in the splash structures was estimated via a theoretical model and several morphological parameters obtained from instantaneous images of the splash. It was observed that the droplet shape and the splashing morphology of RTLM were drastically different from those of water, so was the impact dynamics between room temperature LM pool and high temperature LM pool. The energy analysis disclosed that the height of the jet is highly sensitive to the viscosity of the fluid, which is subjected to the oxidation effect and temperature effect simultaneously, and thus perfectly explained the phenomena. These basic findings are important for the application of RTLM in a series of newly emerging technologies such as liquid metal based spray cooling, ink-jet printed electronics, interface material painting and coating, metallurgy, and 3D packages, etc.

  14. Optimization of Air Conditioning Cycling

    E-Print Network [OSTI]

    Seshadri, Swarooph

    2012-10-19T23:59:59.000Z

    on a 3-ton residential air conditioner are then presented to intuitively understand the effect of expansion valve and evaporator fan cycling in a real system. A real time optimization method is explored and the feasibility, recommendations for a...

  15. Future Air Conditioning Energy Consumption in Developing Countriesand what can be done about it: The Potential of Efficiency in theResidential Sector

    SciTech Connect (OSTI)

    McNeil, Michael A.; Letschert, Virginie E.

    2007-05-01T23:59:59.000Z

    The dynamics of air conditioning are of particular interestto energy analysts, both because of the high energy consumption of thisproduct, but also its disproportionate impact on peak load. This paperaddresses the special role of this end use as a driver of residentialelectricity consumption in rapidly developing economies. Recent historyhas shown that air conditioner ownership can grow grows more rapidly thaneconomic growth in warm-climate countries. In 1990, less than a percentof urban Chinese households owned an air conditioner; by 2003 this numberrose to 62 percent. The evidence suggests a similar explosion of airconditioner use in many other countries is not far behind. Room airconditioner purchases in India are currently growing at 20 percent peryear, with about half of these purchases attributed to the residentialsector. This paper draws on two distinct methodological elements toassess future residential air conditioner 'business as usual' electricityconsumption by country/region and to consider specific alternative 'highefficiency' scenarios. The first component is an econometric ownershipand use model based on household income, climate and demographicparameters. The second combines ownership forecasts and stock accountingwith geographically specific efficiency scenarios within a uniqueanalysis framework (BUENAS) developed by LBNL. The efficiency scenariomodule considers current efficiency baselines, available technologies,and achievable timelines for development of market transformationprograms, such as minimum efficiency performance standards (MEPS) andlabeling programs. The result is a detailed set of consumption andemissions scenarios for residential air conditioning.

  16. 2014-03-06 Issuance: Test Procedures for Packaged Terminal Air...

    Broader source: Energy.gov (indexed) [DOE]

    3-06 Issuance: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps; Notice of Proposed Rulemaking 2014-03-06 Issuance: Test Procedures for...

  17. DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Summit Manufacturing, and Advanced Distributor Products -- must stop distributing 61 heat pump models and 1 air conditioner model that DOE has determined do not comply with...

  18. Interaction of Plutonium with Diverse Materials in Moist Air and Nitrogen-Argon Atmospheres at Room Temperature

    SciTech Connect (OSTI)

    John M. Haschke; Raymond J. Martinez; Robert E. Pruner II; Barbara Martinez; Thomas H. Allen

    2001-04-01T23:59:59.000Z

    Chemical and radiolytic interactions of weapons-grade plutonium with metallic, inorganic, and hydrogenous materials in atmospheres containing moist air-argon mixtures have been characterized at room temperature from pressure-volume-temperature and mass spectrometric measurements of the gas phase. A reaction sequence controlled by kinetics and gas-phase composition is defined by correlating observed and known reaction rates. In all cases, O{sub 2} is eliminated first by the water-catalyzed Pu + O{sub 2} reaction and H{sub 2}O is then consumed by the Pu + H{sub 2}O reaction, producing a gas mixture of N{sub 2}, argon, and H{sub 2}. Hydrogen formed by the reaction of water and concurrent radiolysis of hydrogenous materials either reacts to form PuH{sub 2} or accumulates in the system. Accumulation of H{sub 2} is correlated with the presence of hydrogenous materials in liquid and volatile forms that are readily distributed over the plutonium surface. Areal rates of radiolytic H{sub 2} generation are determined and applied in showing that modest extents of H{sub 2} production are expected for hydrogenous solids if the contact area with plutonium is limited. The unpredictable nature of complex chemical systems is demonstrated by occurrence of the chloride-catalyzed Pu + H{sub 2}O reaction in some tests and hydride-catalyzed nitriding in another.

  19. A P P L I A N C E CEC 400-2005-012

    E-Print Network [OSTI]

    Test Methods........................... 44 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods....................... 45 C ............................................ 72 B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps................... 74

  20. A P P L I A N C E EFFICIENCY REGULATIONS

    E-Print Network [OSTI]

    Test Methods...........................40 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods ......................41 C............................................65 B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps..................67 B

  1. A P P L I A N C E August, 2003

    E-Print Network [OSTI]

    Test Methods........................... 40 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods....................... 41 C ............................................ 65 B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps................... 67

  2. Field Measurements of Efficiency and Duct Effectiveness in Residential Forced Air Distributions Systems

    E-Print Network [OSTI]

    Jump, D.A.

    2011-01-01T23:59:59.000Z

    power for air conditioning, heat pumps and electricwith 13 air conditioners, eight heat pumps (one house hadPre Post * A C : air conditioning, HP : heat pump, GF : gas

  3. An air-to-air heat pump (COP-3.11 at 470 F (8.30C)) run alternately with an electric-resistance water

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    -resistance water heater and a desuperheater water heater was tested under field conditions at a site near Knoxville. One way : . '-~~ .~ Is to use a desuperheater. or heat recovery water heater, with air conditioners are offering . .. .. · ~'*desuperheaier water heaters (DSWI | as options for their central air conditioners

  4. Ventilation Air Preconditioning Systems

    E-Print Network [OSTI]

    Khattar, M.; Brandemuehl, M. J.

    1996-01-01T23:59:59.000Z

    simply and cost-effectively with a dual path arrangement that treats and controls the ventilation air independently of the recirculation air. The Electric Power Research Institute (EPRI)--the nonprofit R&D arm of the electric utility industry... particular type of application. EPRI is developing variations of the dual path concept to meet different reeofit and new construction markets. Figure 6. Ventilation Air Conditioner as a Separate Unit EPRVCALMAC System: Separate Unit for Ventilation Air...

  5. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

    E-Print Network [OSTI]

    2012-01-01T23:59:59.000Z

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

  6. An Index for Evaluation of Air Quality Improvement in Rooms with Personalized Ventilation Based on Occupied Density and Normalized Concentration

    E-Print Network [OSTI]

    Schiavon, Stefano; Melikov, Arsen; Cermak, Radim; De Carli, Michele; Li, Xianting

    2007-01-01T23:59:59.000Z

    Journal of heating, Ventilation and Refrigeration Research,on Cold Climate, Heating, Ventilation and Air-Conditioning,

  7. About Nuccio Heating & Air Headquartered in Tampa, Florida, Nuccio Heating & Air serves

    E-Print Network [OSTI]

    Fisher, Kathleen

    a customer say, `you installed my first air conditioner - yourself!'" Nuccio Heating & Air serves commercialAbout Nuccio Heating & Air Headquartered in Tampa, Florida, Nuccio Heating & Air serves commercial ­ the majority being highly mobile ­ sell and service heating and air conditioning systems for the company

  8. Lee, K.S., Zhang, T., Jiang, Z., and Chen, Q. 2009. "Comparison of airflow and contaminant distributions in rooms with traditional displacement ventilation and under-floor air distribution systems,"

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    systems had higher ventilation performance than the mixing one under cooling mode as well as under heating distributions in rooms with traditional displacement ventilation and under-floor air distribution systems with traditional displacement ventilation and under-floor air distribution systems Kisup Lee* Tengfei Zhang, Ph

  9. Cold Air Distribution in Office Buildings: Technology Assessment for California

    E-Print Network [OSTI]

    Bauman, F.S.

    2008-01-01T23:59:59.000Z

    warmer room air with the cold supply air whenever the supplyroom air diffusion with cold supply air temperatures under

  10. http://pic.sagepub.com/ Engineering Science

    E-Print Network [OSTI]

    Pompili, Dario

    , i.e. computer room air conditioner fan failure, server fan failure, and workload misconfiguration events such as computer room air conditioner (CRAC) fan failure, server fan failure, and workload

  11. Public Meeting: Physical Characterization of Grid-Connected Commercial...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and Definitions; Characterization Protocol Framework; Illustrative Example: Room Air Conditioner (RAC); Process for Developing Characterization Protocols; Overview of...

  12. Fact Sheet: Improving Energy Efficiency for Server Rooms and Closets

    E-Print Network [OSTI]

    Cheung, Hoi Ying Iris

    2014-01-01T23:59:59.000Z

    Heating, Ventilation and Air Conditioning Power Distributionlike a packaged air conditioning unit) for your server room(Refrigerating and Air-Conditioning Engineers’ (ASHRAE)

  13. air conditioners water: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    89. a. Heat flux QA Tx T (QA) x (5000 )...( . . ' the necessary pressure head is z + p(g) 105 + 6523210000 111.65 m. c. Pumping power (gz + p Zevenhoven,...

  14. Determining benefits and costs of improved central air conditioner efficiencies

    E-Print Network [OSTI]

    Rosenquist, G.

    2010-01-01T23:59:59.000Z

    Administration, Annual Energy Outlook 2000, December, 1999.trends from EIA's Annual Energy Outlook 2000 (AE02000) were

  15. Desiccant Moisture Exchange for Dehumidification Enhancement of Air Conditioners

    E-Print Network [OSTI]

    Cromer, C. J.

    1988-01-01T23:59:59.000Z

    . When a high pmpxticm of the werall load an the chiller mil is latent or misture ren~val, this new prooess PnWidee the -ty for cpera*m enerVy mavinge as well as the potenUal for reduced UXt. One l3mct.b of kdldtrrgs, ~xnnrercial and midslrtial...

  16. NREL Solves Residential Window Air Conditioner Performance Limitations (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-05-01T23:59:59.000Z

    Comprehensive performance tests lead to enhanced modeling capability and affordable methods to increase energy efficiency.

  17. Determining benefits and costs of improved central air conditioner efficiencies

    E-Print Network [OSTI]

    Rosenquist, G.

    2010-01-01T23:59:59.000Z

    of Energy-Energy Information Administration, A Look atof Energy-Energy Information Administration, 1995 Commercialof Energy-Energy Information Administration, Annual Energy

  18. Cromer Cycle Air Conditioner: A Study to Confirm Target Performance

    E-Print Network [OSTI]

    Cromer, C. J.

    2001-01-01T23:59:59.000Z

    . That evening, the wheel was removed and the duct resealed. The two days had quite similar weather and the data obtained and can provide some insight into the system operation. COMPARATIVE DATA Table 1 provides a data set for the system operating without...

  19. DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS

    E-Print Network [OSTI]

    Dao, K.

    2013-01-01T23:59:59.000Z

    ROAD BERKELEY, CALIFORNIA OBJECTIVE AND APPROACH The objective of this project is the development of absorption refrigeration systems for solar

  20. air conditioners energy: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Summary: -16 Grant Funding: 74,547 Term: February 2001 - June 2003 PIER Subject Area: Renewable Energy Technologies areas: Residential and Commercial Building...

  1. Determining benefits and costs of improved central air conditioner efficiencies

    E-Print Network [OSTI]

    Rosenquist, G.

    2010-01-01T23:59:59.000Z

    Engineers, Inc. , Energy Efficient Design of New BuildingsStandard 90.1, Energy Efficient Design of New Buildings

  2. Determining benefits and costs of improved central air conditioner efficiencies

    E-Print Network [OSTI]

    Rosenquist, G.

    2010-01-01T23:59:59.000Z

    analyze, the energy price projection, and the start year (uncertainty of projections offuture energy prices, the LCC

  3. Ductless Mini-Split Air Conditioners | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently20,000 Russian NuclearandJunetrack graphics4Dimitri Kusnezov -Purpose(FY)TheA ductless

  4. air conditioner utilizing: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Conditions - The Utility Perspective Ammi Amarnath Technical Leader, Energy Efficiency & Demand Response Program Electric Power Research Institute 3420 Hillview Avenue Palo Alto,...

  5. Central Air Conditioner Enforcement Policy Statement | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube platformBuilding RemovalCSS LetterStateDepartmentAnnounce Results of

  6. Enforcement Policy Statement: Off Mode Standards for Central Air Conditioners

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011AT&T,OfficeEnd of Year 2010 SNFEnergySession0-02 - December 23,Energy

  7. Four Central Air Conditioners Determined Noncompliant With Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport inEnergy0.pdf Flash2010-60.pdf2 DOE HydrogenPlansDecades

  8. High-Efficiency Window Air Conditioners - Building America Top Innovation |

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy ChinaofSchaefer To:Department of EnergySeacrist, Senior FellowDepartment ofDepartment

  9. Covered Product Category: Residential Central Air Conditioners | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"Wave theJuly 30, 2013DepartmentEnterprise ServersHotDepartmentof

  10. Commercial Air Conditioners and Heat Pumps | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy China U.S. DepartmentEnergy This partAs the Department ofAARP, NASUCA,The Department

  11. 13-Energy Efficiency Ratio Window Air Conditioner | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic2UraniumEnergy CityDepartment ofNuclear Information100% Cleanhe12 Days

  12. History of the Air Conditioner | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122Commercial602 1,397 125 QDecemberBlogFEES FOIA FEESGraphicsforHead

  13. Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy Chinaof EnergyImpactOn July 2, 2014 in theGroupJuneThis primer on

  14. Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)

    SciTech Connect (OSTI)

    Kozubal, E.

    2013-02-01T23:59:59.000Z

    This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

  15. Radio-Frequency Beam Conditioner for Fast-Wave Free-Electron Generators of Coherent Radiation

    E-Print Network [OSTI]

    Sessler, Andrew M.

    2008-01-01T23:59:59.000Z

    to Physical Review Letters Radio-Frequency Beam ConditionerDE-AC03-76SF00098 LBL-31006 RADIO-FREQUENCY BEAM CONDITIONERIbaraki, 305, Japan. RADIO-FREQUENCY BEAM CONDITIONER FOR

  16. Cromer Cycle Air Conditioner: A Unique Air-Conditioner Desiccant Cycle to Enhance Dehumidification and Save Energy

    E-Print Network [OSTI]

    Cromer, C. J.

    2000-01-01T23:59:59.000Z

    for the AC system. The desiccant wheel was slid into the duct system and a test run completed. The wheel was then removed from the system, the ducts resealed, and an additional test run completed. By this alternation method, three runs with the wheel...

  17. High Energy Efficiency Air Conditioning

    SciTech Connect (OSTI)

    Edward McCullough; Patrick Dhooge; Jonathan Nimitz

    2003-12-31T23:59:59.000Z

    This project determined the performance of a new high efficiency refrigerant, Ikon B, in a residential air conditioner designed to use R-22. The refrigerant R-22, used in residential and small commercial air conditioners, is being phased out of production in developed countries beginning this year because of concerns regarding its ozone depletion potential. Although a replacement refrigerant, R-410A, is available, it operates at much higher pressure than R-22 and requires new equipment. R-22 air conditioners will continue to be in use for many years to come. Air conditioning is a large part of expensive summer peak power use in many parts of the U.S. Previous testing and computer simulations of Ikon B indicated that it would have 20 - 25% higher coefficient of performance (COP, the amount of cooling obtained per energy used) than R-22 in an air-cooled air conditioner. In this project, a typical new R-22 residential air conditioner was obtained, installed in a large environmental chamber, instrumented, and run both with its original charge of R-22 and then with Ikon B. In the environmental chamber, controlled temperature and humidity could be maintained to obtain repeatable and comparable energy use results. Tests with Ikon B included runs with and without a power controller, and an extended run for several months with subsequent analyses to check compatibility of Ikon B with the air conditioner materials and lubricant. Baseline energy use of the air conditioner with its original R-22 charge was measured at 90 deg F and 100 deg F. After changeover to Ikon B and a larger expansion orifice, energy use was measured at 90 deg F and 100 deg F. Ikon B proved to have about 19% higher COP at 90 deg F and about 26% higher COP at 100 deg F versus R-22. Ikon B had about 20% lower cooling capacity at 90 deg F and about 17% lower cooling capacity at 100 deg F versus R-22 in this system. All results over multiple runs were within 1% relative standard deviation (RSD). All of these values agree well with previous results and computer simulations of Ikon B performance versus R-22. The lower cooling capacity of Ikon B is not a concern unless a particular air conditioner is near its maximum cooling capacity in application. Typically, oversized A/C systems are installed by contractors to cover contingencies. In the extended run with Ikon B, which lasted about 4.5 months at 100 deg F ambient temperature and 68% compressor on time, the air conditioner performed well with no significant loss of energy efficiency. Post-run analysis of the refrigerant, compressor lubricant oil, compressor, compressor outlet tubing, and the filter/dryer showed minor effects but nothing that was considered significant. The project was very successful. All objectives were achieved, and the performance of Ikon B indicates that it can easily be retrofitted into R-22 air conditioners to give 15 - 20% energy savings and a 1 - 3 year payback of retrofit costs depending on location and use. Ikon B has the potential to be a successful commercial product.

  18. Cold air distribution in office buildings: technology assessment for califonia

    E-Print Network [OSTI]

    Bauman, Fred; Borgers, T.; LaBerge, P.; Gadgil, A.

    1993-01-01T23:59:59.000Z

    room air with the cold supply air whenever the supplyroomair diffusion with cold supply air temperatures space

  19. Study on Energy Saving of the Interlayer Ventilation Walla Used in Clean Operation Rooms

    E-Print Network [OSTI]

    Feng, J.; Lian, Z.; Hou, Z.

    2006-01-01T23:59:59.000Z

    Recovery energy of the exhaust in air conditioning is very important to clean operating rooms. In disinfected operating rooms, we often use completely fresh air conditioning system in order to maintain cleanliness. All the return air of the air...

  20. A PLASMA CHANNEL BEAM CONDITIONER FOR A FREE ELECTRON LASER

    E-Print Network [OSTI]

    Wurtele, Jonathan

    A PLASMA CHANNEL BEAM CONDITIONER FOR A FREE ELECTRON LASER G. Penn , A.M. Sessler, J.S. Wurtele of free electron lasers (FELs) can be dramatically improved. Under certain con- ditions, the FEL can transverse action and energy, has been shown to be advantageous for free electron laser (FEL) performance [1

  1. Golden Opportunity: Proposed Penalty (2014-CE-20003)

    Broader source: Energy.gov [DOE]

    DOE alleged in a Notice of Proposed Civil Penalty that Golden Opportunity, Inc. failed to certify room air conditioners, central air conditioners/heat pumps, and residential clothes washers as compliant with the applicable energy conservation standards.

  2. Using National Survey Data to Estimate Lifetimes of Residential Appliances

    E-Print Network [OSTI]

    Lutz, James D.

    2013-01-01T23:59:59.000Z

    conditioners, heat pumps, furnaces, boilers, water heaters,conditioners, heat pumps, furnaces, boilers, water heaters,Water Heater, Gas Room Air- Conditioning Central Air- Conditioning Boiler, Gas Furnace, Gas Heat Pump *

  3. Temperature, Power, and Makespan Aware Dependent Task Scheduling for Data Zheng Li, Li Wang, and Shangping Ren

    E-Print Network [OSTI]

    Quan, Gang

    conditioners are used to supply cold air and remove heat from the center. The supplied air must be cold enough of a server, the lower the temperature of cooling air provided by the air conditioner has to be. Unfortunately, as pointed out by Moore [4], lowing the room air conditioner's working temperature degrades its capability

  4. Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in the United States

    E-Print Network [OSTI]

    Bojda, Nicholas

    2011-01-01T23:59:59.000Z

    2010m). Residential Water Heater National Impacts AnalysisRoom AC  Televisions  Water Heaters  Commercial Products Room Air Conditioners Water Heaters Televisions Standby

  5. AEP Ohio - Commercial New Construction Energy Efficiency Rebate...

    Broader source: Energy.gov (indexed) [DOE]

    Refrigerant Flow Air Conditioners: 20ton Chillers: 15 - 20ton Geothermal Heat Pump: 80ton Water Source Heat Pump: 70ton Room AC: 30ton Hotel Room Occupancy...

  6. Computer Room Fresh Air Cooling

    E-Print Network [OSTI]

    Wenger, J. D.

    1985-01-01T23:59:59.000Z

    suggests that because of the cycling nature of their controls, direct expansion (DX) systems may not be able to meet the strict humidity specifications for underfloor del ivery at all times (1). Becker a1 so points out that water vapor migration due... modulated, or a continuous1 y wetted humidification pad with face and bypass dampers for control. as suggested by Becker. The fogger would be chosen if an adequate supply of distilled or hyperfil tered water is available and the wetted pad would...

  7. Heat transfer pathways in underfloor air distribution (UFAD) systems

    E-Print Network [OSTI]

    Bauman, F.; Jin, H.; Webster, T.

    2006-01-01T23:59:59.000Z

    room cooling load, room air setpoint, and supply air temper-distribution of room cooling load into the supply plenum orof room cooling load between the underfloor supply plenum

  8. Spring is in the Air and so is a Plethora of Pollen Dr. Joan Bradshaw, County Extension Director

    E-Print Network [OSTI]

    Jawitz, James W.

    and skin. Use air filters and clean regularly, or run an air conditioner and change the air filterSpring is in the Air and so is a Plethora of Pollen Dr. Joan Bradshaw, County Extension Director, Suite 1 Lecanto, FL 34461 Springtime is in the air in Citrus County with its glorious weather

  9. Golden Opportunity: Order (2014-CE-20003) | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Golden Opportunity had failed to certify that certain models of room air conditioners, central air conditionersheat pumps, and residential clothes washers comply with the...

  10. Heat Controller: Noncompliance Determination (2014-SE-15004)...

    Office of Environmental Management (EM)

    a Notice of Noncompliance Determination to Heat Controller, Inc. finding that the room air conditioner distributed in commerce by Heat Controller as Comfort Aire brand models...

  11. 1International Exchange Student Accommodation There are about 1300 units in on-campus dorms. Basically, the international exchange students

    E-Print Network [OSTI]

    Petriu, Emil M.

    -bed room8-bed room, no bathroom inside. Beds, desks, closet, air-conditioner, and the Internet access, air-conditioner, bathroom, and the Internet access are included in every room. Other facilities included. The charge for internet connection, air conditioning are not included. 3. Rooms for winter

  12. BEETIT: Building Cooling and Air Conditioning

    SciTech Connect (OSTI)

    None

    2010-09-01T23:59:59.000Z

    BEETIT Project: The 14 projects that comprise ARPA-E’s BEETIT Project, short for “Building Energy Efficiency Through Innovative Thermodevices,” are developing new approaches and technologies for building cooling equipment and air conditioners. These projects aim to drastically improve building energy efficiency and reduce greenhouse gas emissions such as carbon dioxide (CO2) at a cost comparable to current technologies.

  13. King Air flight RICO 2004/12/13 page 1 King Air N2UW flight report for December 13, 2004

    E-Print Network [OSTI]

    Vali, Gabor

    repair of the air conditioner on the aircraft, a test flight was needed and was to be transformedKing Air flight ­ RICO ­ 2004/12/13 page 1 King Air N2UW flight report for December 13, 2004 Crew: Drew, Vali, Oolman, Glover After

  14. Use of chlorofluorocarbons in refrigeration, insulation and mobile air conditioning in the USA*

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    FILE COPY DO NOT REMOVE Use of chlorofluorocarbons in refrigeration, insulation and mobile air in refrigeration equipment and mobile air conditioners, or as the blowing agent in foam insulations. When again accounted for _ 40 %of the potential risk to the environment. Refrigeration, mobile air

  15. Investigating the Performance of Solar Air Conditioning Motivation/Background Findings

    E-Print Network [OSTI]

    -thermal collectors We investigated 3 types of solar cooling technologies: · Air conditioning consumes 10% of all collector size is a critical limiting factor of solar air conditioners · High driving temperatureInvestigating the Performance of Solar Air Conditioning Motivation/Background Findings Two Building

  16. Air Conditioning with Magnetic Refrigeration : An Efficient, Green Compact Cooling System Using Magnetic Refrigeration

    SciTech Connect (OSTI)

    None

    2010-09-01T23:59:59.000Z

    BEETIT Project: Astronautics is developing an air conditioning system that relies on magnetic fields. Typical air conditioners use vapor compression to cool air. Vapor compression uses a liquid refrigerant to circulate within the air conditioner, absorb the heat, and pump the heat out into the external environment. Astronautics’ design uses a novel property of certain materials, called “magnetocaloric materials”, to achieve the same result as liquid refrigerants. These magnetocaloric materials essentially heat up when placed within a magnetic field and cool down when removed, effectively pumping heat out from a cooler to warmer environment. In addition, magnetic refrigeration uses no ozone-depleting gases and is safer to use than conventional air conditioners which are prone to leaks.

  17. Comparing Mainframe and Windows Server Transactions per kWh

    E-Print Network [OSTI]

    Narasayya, Vivek

    ..................................................................................................................................15 Air Conditioner (Heat Pump) Efficiency Units

  18. DOE Takes Action to Stop the Sales of Air-Con Air Conditioner...

    Office of Environmental Management (EM)

    and Proposed Civil Penalty (pdf - 234kb). Follow the Department of Energy on Facebook, Twitter, Youtube and Flickr. Follow Secretary Chu on his Facebook page. Media...

  19. The Effect of Reduced Evaporator Air Flow on the Performance of a Residential Central Air Conditioner

    E-Print Network [OSTI]

    Palani, M.; O'Neal, D.; Haberl, J.

    COMPONENT SPECIFICATION COMPRESSOR Single Speed, 230 V, SOp A...A 17.1 and LRA 79.0 amps Employs internal line breaker(IOL) Internal Pressure Relief OPR) opens at 350 psig difference STRAINER DRIER Discharge line WiUl sweat fitting 8 cubic inch, 3/8 X... for electrical controls and miscellaneous electrical devices represented 31.4% of the total number of failures and refrigerant leaks constituted 17.2% of the total failure. The failure rates of compressors was 13.5% and outdoor fans was about I 1.5%. Lewis...

  20. DOE Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613PortsmouthBartlesvilleAbout »DepartmentLaboratory |and Loan Recipients | Departmentto

  1. Establish the Commercial Pacakge Air Conditioners and Commercial Warm Air Furnaces WG

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: The Future of Bad CholesteroliManage Presentation3 DATE: March 14,62008

  2. Air conditioning system

    DOE Patents [OSTI]

    Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

    2005-02-01T23:59:59.000Z

    An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

  3. News Room

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOnItemResearch > The EnergyCenterDioxideDocumentationThreeNews Releases NewsRoom

  4. Electronics Come of Age: A Taxonomy for Miscellaneous and Low Power Products

    E-Print Network [OSTI]

    Nordman, Bruce; Sanchez, Marla C.

    2006-01-01T23:59:59.000Z

    central Air conditioning, heat pump Air conditioning, room/unit — any fuel type), central air conditioning, heat pumpair conditioner (room or wall unit) Tank units (electric, gas, heat pump,

  5. Bigwall: Noncompliance Determination (2014-SE-15006) | Department...

    Office of Environmental Management (EM)

    ("Bigwall model PACH8000") of room air conditioners do not comport with the energy conservation standards. DOE determined the product was noncompliant based on DOE testing....

  6. International Comparison of Energy Efficiency Awards for Appliance Manufacturers and Retailers

    E-Print Network [OSTI]

    Zhou, Nan

    2014-01-01T23:59:59.000Z

    Washers Residential Dishwashers Tankless Water HeatersStorage Water Heaters Room Air Conditioners Total Totalresidential gas tankless water heaters; residential gas

  7. ENVIRONMENTAL ASSESSMENT FOR PROPOSED ENERGY CONSERVATION STANDARDS...

    Broader source: Energy.gov (indexed) [DOE]

    ENVIRONMENTAL ASSESSMENT FOR PROPOSED ENERGY CONSERVATION STANDARDS FOR EIGHT TYPES OF CONSUMER PRODUCTS: ROOM AIR CONDITIONERS, WATER HEATERS, DIRECT HEATING EQUI?MENT, MOBILE...

  8. The Department of Energy (DOE) develops standardized data templates...

    Energy Savers [EERE]

    Single Packaged Vertical Unit - v1.0.xlsx More Documents & Publications Room Air Conditioners Commercial Refrigeration Equipment Standardized Templates for Reporting Test Results...

  9. Verdigris Valley Electric Cooperative- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Verdigris Valley Electric Cooperative (VVEC) offers rebates for residential customers who purchase energy efficient home equipment. Rebates are available for room air conditioners, electric water...

  10. U.S. Energy Information Administration (EIA)

    Gasoline and Diesel Fuel Update (EIA)

    dishwashers, and room air conditioners. The latest efficiency rulemaking for residential water heaters includes a provision for higher standards on electric and natural gas...

  11. Buying an Appliance this Holiday Season? ENERGY STAR Products...

    Office of Environmental Management (EM)

    Freezers Room air conditioners Televisions Clothes washers Dishwashers Battery chargers Water heaters Fluorescent lamp ballasts Incandescent reflector lamps If your appliance has...

  12. Study on Influencing Factors of Night Ventilation in Office Rooms

    E-Print Network [OSTI]

    Wang, Z.; Sun, X.

    2006-01-01T23:59:59.000Z

    A mathematical and physical model on night ventilation is set up. The fields of indoor air temperature, air velocity and thermal comfort are simulated using Airpak software. Some main influencing factors of night ventilation in office rooms...

  13. Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature? 

    E-Print Network [OSTI]

    Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

    2002-01-01T23:59:59.000Z

    space area. Room temperatures are controlled by pneumatic thermostats. The AHU has a minimum outside air damper and a maximum outside air damper. The minimum outside air damper is fully open when the AHU is in operation. The maximum outside air... of thermostat, and the relationship between room temperature set point and return air temperature. The Role Of Thermostat Traditional pneumatic thermostat is a proportional (P) type controller. It senses the space temperature changes and produces...

  14. RoomZoner: Occupancy-based Room-Level Zoning of a Centralized HVAC System

    E-Print Network [OSTI]

    Whitehouse, Kamin

    RoomZoner: Occupancy-based Room-Level Zoning of a Centralized HVAC System Tamim Sookoor & Kamin. In this paper we present a CPS that enables a centralized Heating, Ventila- tion, and Air Conditioning (HVAC application due to residential HVAC systems ac- counting for over 15% of all U.S. energy usage, making it one

  15. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces

    SciTech Connect (OSTI)

    Not Available

    1993-11-01T23:59:59.000Z

    This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

  16. Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy

    E-Print Network [OSTI]

    Fuller, Merrian C.

    2011-01-01T23:59:59.000Z

    water heater replacement, air conditioner replacement, solarwater heater replacement, air conditioner replacement, solar

  17. Delivering Energy Efficiency to Middle Income Single Family Households

    E-Print Network [OSTI]

    Zimring, Mark

    2012-01-01T23:59:59.000Z

    water heater replacement, air conditioner Assumptions behindreplacements (e.g. , furnace, water heater, air conditioner,

  18. Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy

    E-Print Network [OSTI]

    Fuller, Merrian C.

    2011-01-01T23:59:59.000Z

    replacement, air conditioner replacement, solar thermalreplacement, air conditioner replacement, solar thermal

  19. Market and behavioral barriers to energy efficiency: A preliminary evaluation of the case for tariff financing in California

    E-Print Network [OSTI]

    Fujita, K. Sydny

    2012-01-01T23:59:59.000Z

    Central Air Conditioners and Heat Pumps. ” Department ofrecent central air conditioner and heat pump purchasers only

  20. Classroom Vocabulary Classroom Vocabulary [msamiati wa darasani

    E-Print Network [OSTI]

    ] [wall clock] [map / maps] [air conditioner / air conditioners] [picture / pictures] [drawing / drawings

  1. Flow conditioner for fuel injector for combustor and method for low-NO.sub.x combustor

    DOE Patents [OSTI]

    Dutta, Partha; Smith, Kenneth O.; Ritz, Frank J.

    2013-09-10T23:59:59.000Z

    An injector for a gas turbine combustor including a catalyst coated surface forming a passage for feed gas flow and a channel for oxidant gas flow establishing an axial gas flow through a flow conditioner disposed at least partially within an inner wall of the injector. The flow conditioner includes a length with an interior passage opening into upstream and downstream ends for passage of the axial gas flow. An interior diameter of the interior passage smoothly reduces and then increases from upstream to downstream ends.

  2. Exposure assessment of particulate matter air pollution before, during, and after the 2003 Southern California wildfires

    E-Print Network [OSTI]

    Wu, J; Winer, A M; Delfino, R J

    2006-01-01T23:59:59.000Z

    Ostra, B. , 1997. Air pollution and emergency room visitsJ. , 1994. Indoor air pollution and asthma: Results from aof unmeasured particulate air pollution data for an

  3. Catalog of DC Appliances and Power Systems

    E-Print Network [OSTI]

    Garbesi, Karina

    2012-01-01T23:59:59.000Z

    DC solar-powered DC air-conditioning heat pump produced byRoom Air Conditioners Geothermal Heat Pumps Lighting-efficiency of an air source electric heat-pump water heater

  4. Alexandria Light and Power - Residential Energy Efficiency Rebate...

    Broader source: Energy.gov (indexed) [DOE]

    -Dehumidifiers -Room Air Conditioners -ECM in New FurnaceAir HandlerFan Coil -Water Heaters -Central AC -Geothermal and Air-Source Heat Pumps ALP also offers a rebates...

  5. Room to grow | EMSL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Room to grow Room to grow Released: June 26, 2012 New lithium ion battery strategy offers more energy, longer life cycle In situ transmission electron microscopy at EMSL was used...

  6. Research on Cool Storage Time of a Phase Change Wallboard Room in the Summer 

    E-Print Network [OSTI]

    Feng, G.; Liang, R.; Li, G.

    2006-01-01T23:59:59.000Z

    Through testing and analysis of the parameters of the indoor thermal property in a phase change wallboard room and an ordinary room, the effects of using phase change wallboards on indoor temperature in summer and with air ...

  7. Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement

    E-Print Network [OSTI]

    Bode, Josh

    2013-01-01T23:59:59.000Z

    measurements using smart meter household data produce theof program households. Smart meters lower the cost of usingsample sizes with smart meter data can be far larger than

  8. Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement

    E-Print Network [OSTI]

    Bode, Josh

    2013-01-01T23:59:59.000Z

    regions. In addition, the SCADA was not available for allData Real Time Visibility SCADA 5 minutes or less Limited

  9. Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement

    E-Print Network [OSTI]

    Bode, Josh

    2013-01-01T23:59:59.000Z

    of California Statewide Aggregator Demand Response Programs.Analysis of AMP Aggregator Demand Response Program. Preparedof California Statewide Aggregator Demand Response Programs.

  10. An Analysis of Efficiency Improvements in Residential Sized Heat Pumps and Central Air Conditioners

    E-Print Network [OSTI]

    O'Neal, D. L.; Boecker, C. L.; Penson, S. B.

    1986-01-01T23:59:59.000Z

    ) Increased tube rows 3.1 1C) Increased fin density 3.2 ID) Increased heat transfer coefficient 3.2 IE) Increased parallel circuits 3.2 2) Decreased Compressor Size 3.2 3) Increased Combined Fan and Motor Efficiency 3.2 4) Demand Defrost Control Systems (Heat... Pumps Only) 3.3 5) High Efficiency Compressors 3.3 6) Two Speed Compressors 3.3 References 3.4 iii CHAPTER PAGE 4 CONVENTIONAL DESIGN IMPROVEMENTS: RESULTS 4.1 Heat Pumps 4.1 Baseline Units 4.2 Final Conventional Designs 4.7 3 Ton Split Systems 4.7 3 Ton...

  11. Determination of the Transient Dehumidification Characteristics of High Efficiency Central Air Conditioners

    E-Print Network [OSTI]

    Katipamula, S.; O'Neal, D. L.; Somasundaram, S.

    1987-01-01T23:59:59.000Z

    Seasonal Energy Efficiency Ratio SHR Sensible Heat Ratio TOCZ Time Outside the Comfort Zone TMY Typical Meteorological Year TRNSYS TRaNsient SYstem Simulation ii SUMMARY A series of tests were performed to assesses the dehumidifying performance... DEVELOPMENT OF NEW ROUTINES 12 A. HVAC CONTROL MODULE 12 B. POST-PROCESSING OF THE TRNSYS OUTPUT 13 6 SELECTION OF TEST DAYS 14 7 BASE CASE 19 A. EVALUATION OF THE DESIGN LOAD 19 B. EVALUATION OF THE 14 CAC UNITS FOR BASE CASE ... 20 C. DISCUSSION OF BASE CASE...

  12. Analysis of Efficiency Standards for Air Conditioners, Heat Pumps, and Other Products

    Reports and Publications (EIA)

    2002-01-01T23:59:59.000Z

    A series of analyses showing the impacts of each of the selected provisions of the bills on energy supply, demand, and prices, macroeconomic variables where feasible, import dependence, and emissions.

  13. Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement

    E-Print Network [OSTI]

    Bode, Josh

    2013-01-01T23:59:59.000Z

    93 Figure I-1: Electricty Use for a Specific Feeder in Santerritory. Figure I-1: Electricty Use for a Specific Feeder

  14. Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement

    E-Print Network [OSTI]

    Bode, Josh

    2013-01-01T23:59:59.000Z

    017F.PDF KEMA, Inc. 2011. PJM Empirical Analysis of DemandMethods. Prepared for the PJM Markets Implementation~/media/markets-ops/dsr/pjm-analysis-of-dr-baseline-methods-

  15. DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613PortsmouthBartlesvilleAbout »Department of2 DOE FitsEnergyMessagein

  16. DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613PortsmouthBartlesvilleAbout »Department of2Violating Minimum Appliance Standards |

  17. Tips for Running an Air Conditioner Without Breaking the Bank | Department

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you sure you wantJoin us for|Idahothe New Funding Constructs forofDOETips Forof

  18. 2015-02-12 Issuance: Test Procedures for Portable Air Conditioners; Notice

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy China 2015ofDepartment ofCBFO-13-3322(EE)DepartmentVery5 AnnualDillingham,7,58of Proposed

  19. Advanced Thin Film Thermoelectric Systems forEfficient Air-Conditioners |

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy China 2015ofDepartmentDepartment of2Partners in the Spotlight Novelis2AdvancedofDepartment

  20. DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"WaveInteractions and Policy (2009) | Department

  1. DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"WaveInteractions and PolicyCybersecurity ThreatsViolating Minimum

  2. DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"WaveInteractions and PolicyCybersecurity ThreatsViolating

  3. Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMay 2015 <Department ofDepartment| Department of Energy Money and Stay

  4. YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your DensityEnergy U.S.-China Electric VehicleCenters |-- 9:00 AM OpeningWorld's LargestYou |Y-12I

  5. Tips for Running an Air Conditioner Without Breaking the Bank | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMayDepartmentTest for PumpingThe| Department of EnergyPhaseCostsTipTipsof

  6. Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature?

    E-Print Network [OSTI]

    Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

    2002-01-01T23:59:59.000Z

    space area. Room temperatures are controlled by pneumatic thermostats. The AHU has a minimum outside air damper and a maximum outside air damper. The minimum outside air damper is fully open when the AHU is in operation. The maximum outside air... understand how this reset scheme responds to building load change, thus resulting in supply air temperature reset, it is helpful to explain the role of thermostat. In the following section, we explain the way how the thermostat works, the type...

  7. Midea: Proposed Penalty (2013-SE-1505) | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Midea Air-Conditioning Equipment Co. Ltd. manufactured and distributed noncompliant room air conditioner basic model MWJ1-08ERN1-BI8 in the U.S. Federal law subjects manufacturers...

  8. INFLUENCE OF SUPPLY AIR TEMPERATURE ON UNDERFLOOR AIR DISTRIBUTION (UFAD) SYSTEM ENERGY PERFORMANCE

    E-Print Network [OSTI]

    2012-01-01T23:59:59.000Z

    chilled water cooling coil, and supply fan. The fan is aspecify the VAV box cooling design supply air temperature (the underfloor supply plenum (thereby, reducing room cooling

  9. Cash for Coolers

    E-Print Network [OSTI]

    Davis, Lucas W.; Fuchs, Alan; Gertler, Paul J.

    2012-01-01T23:59:59.000Z

    for refrigerator and air conditioner replacement and allof refrigerator and air-conditioner replacement on householdthat replacement of residential air conditioners would save

  10. Impact of Large Scale Energy Efficiency Programs On Consumer Tariffs and Utility Finances in India

    E-Print Network [OSTI]

    Abhyankar, Nikit

    2011-01-01T23:59:59.000Z

    like refrigerator and air conditioner replacements. Thisiv) Replacement of conventional air conditioners by energy-ii) Replacement of conventional air conditioners by energy-

  11. Cash for Coolers

    E-Print Network [OSTI]

    Davis, Lucas W.; Fuchs, Alan; Gertler, Paul J.

    2012-01-01T23:59:59.000Z

    of refrigerator and air-conditioner replacement on householdfor refrigerator and air conditioner replacement and allassociated with air-conditioner replacement were to be

  12. Impact of Large Scale Energy Efficiency Programs On Consumer Tariffs and Utility Finances in India

    E-Print Network [OSTI]

    Abhyankar, Nikit

    2011-01-01T23:59:59.000Z

    like refrigerator and air conditioner replacements. This5-star air conditioners are the efficient replacement, withiv) Replacement of conventional air conditioners by energy-

  13. Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms

    E-Print Network [OSTI]

    Apte, Michael; Michael G. Apte, Bourassa Norman, David Faulkner, Alfred T. Hodgson,; Toshfumi Hotchi, Michael Spears, Douglas P. Sullivan, and Duo Wang

    2008-01-01T23:59:59.000Z

    a prototype improved heat pump air conditioner was developedwith standard 10 SEER heat pump air conditioner equipment.generated by the wall mount heat pump air conditioner (HPAC)

  14. FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH

    E-Print Network [OSTI]

    Lesieutre, Bernard

    2013-01-01T23:59:59.000Z

    9   1.2.1.   Air Conditioner Testing and 16   2.0   Air Conditioner Results of Residential Air Conditioner Testing in WECC,” 

  15. Current Status and Future Scenarios of Residential Building Energy Consumption in China

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    in MJ /household-year. Air conditioner and refrigerator endand 217.4% for air conditioner in Japan in 2000 (IEEJ,appliances including air conditioner, refrigerator, clothes

  16. Modeling diffusion of electrical appliances in the residential sector

    E-Print Network [OSTI]

    McNeil, Michael A.

    2010-01-01T23:59:59.000Z

    Error Distribution - Air Conditioners Error Distribution -televisions, and air conditioners 5 . The task of modelingfrom UNDESA. 2.1.3. Air Conditioner Climate Variable

  17. RESIDENTIAL THERMOSTATS: COMFORT CONTROLS IN CALIFORNIA HOMES

    E-Print Network [OSTI]

    Meier, Alan K.

    2008-01-01T23:59:59.000Z

    Measures on Residential Air Conditioner Loads. Proc. ACEEEDeterminants of Central Air Conditioner Duty Cycles. Proc.at the number of air conditioners that might actually

  18. TWOZONE USERS MANUAL. 2d ed

    E-Print Network [OSTI]

    Gadgil, A.J.

    2008-01-01T23:59:59.000Z

    cooler, improved air conditioner algorithm, ability to readcooling the house with air-conditioner, evaporative-cooler= starting month of air-conditioner (AC) operation. = ending

  19. Customer Impact Evaluation for the 2009 Southern California Edison Participating Load Pilot

    E-Print Network [OSTI]

    Gifford, William

    2010-01-01T23:59:59.000Z

    duration interruptions of air-conditioners. Still, we should14 3.2.2 Typical Summer Air Conditioner15 Table 3.3 Air Conditioner

  20. Bioenergy 2015 Press Room

    Broader source: Energy.gov [DOE]

    This U.S. Department of Energy Bioenergy 2015 online press room provides contacts, information, and resources to members of the media who cover Bioenergy 2015 conference-related news.

  1. Numerical Analysis of Heat and Moisture Transfer in Underground Air-conditioning Systems

    E-Print Network [OSTI]

    Wang, Q.; Miao, X.; Cheng, B.; Fan, L.

    2006-01-01T23:59:59.000Z

    In view of the influence of humidity of room air on room heat load, indoor environment and building energy consumption in underground intermittent air-conditioning systems, numerical simulation was used to dynamically analyze the coupling condition...

  2. Tariff-based analysis of commercial building electricity prices

    E-Print Network [OSTI]

    Coughlin, Katie M.; Bolduc, Chris A.; Rosenquist, Greg J.; Van Buskirk, Robert D.; McMahon, James E.

    2008-01-01T23:59:59.000Z

    Central Air Conditioners and Heat Pump Energy ConservationUnitary Air Conditioners and Heat Pumps ANOPR Technical

  3. Current Status and Future Scenarios of Residential Building Energy Consumption in China

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    stove district heating heat pump air conditioner Table 2Heat Pump Percentage (%) Heat Pump Air Conditioner District

  4. Room Policies Printing Options

    E-Print Network [OSTI]

    , please return them to the desk for new ones. Saving the stuff you write on the Whiteboard 1. Make the room as bright as you can for best contrast 2. Hit the "Save to Web" button on the gray wall box 3, they are incorrect. #12;2. Click on your image to enlarge it. Click on the image to get the `save' option. Save

  5. Cryo Utilities Room Cooling System

    SciTech Connect (OSTI)

    Ball, G.S.; /Fermilab

    1989-01-26T23:59:59.000Z

    Many of the mechanical equipment failures at the Laboratory are due to the loss of cooling water. In order to insure the proper operating temperatures and to increase the reliability of the mechanical equipment in the D0 Cryo Utilities Room it is necessary to provide an independent liquid cooling system. To this end, an enclosed glycoVwater cooling system which transfers heat from two vane-type vacuum pumps and an air compressor to the outside air has been installed in the Cryo Utilities Room. From the appended list it can be seen that only the Thermal Precision PFC-121-D and Ingersoll-Rand WAC 16 deserve closer investigation based on price. The disadvantages of the WAC 16 are that: it runs a little warmer, it requires more valving to properly install a backup pump, inlet and outlet piping are not included, and temperature and pressure indicators are not included. Its only advantage is that it is $818 cheaper than the PFC-121-D. The advantages of the PFC-121-D are that: it has automatic pump switching during shutdown, it has a temperature regulator on one fan control, it has a switch which indicates proper operation, has a sight glass on the expansion tank, and comes with an ASME approved expansion tank and relief valve. For these reasons the Thermal Precision PFC-121-D was chosen. In the past, we have always found the pond water to be muddy and to sometimes contain rocks of greater than 1/2 inch diameter. Thus a system completely dependent on the pond water from the accelerator was deemed unacceptable. A closed system was selected based on its ability to greatly improve reliability, while remaining economical. It is charged with a 50/50 glycol/water mixture capable of withstanding outside temperatures down to -33 F. The fluid will be circulated by a totally enclosed air cooled Thermal Precision PFC-121-D pump. The system will be on emergency power and an automatically controlled backup pump, identical to the primary, is available should the main pump fail. The fan unit is used as a primary cooler and the trim cooler cools the fluid further on extremely hot days. The trim cooler has also been sized to cool the system in the event of a total shutdown provided that the pond water supply has adequate pressure. Due to a broken filter, we found it necessary to install a strainer in the pond water supply line. The expansion tank separates air bubbles, ensures a net positive suction head, protects against surges and over pressurization of the system, and allows for the filling of the system without shutting it off. All piping has been installed, flushed, charged with the glycol/water mix, and hydrostatically tested to 55 psi. The condition of all pumps and flow conditions will be recorded at the PLC. It has been decided not to include the regulator valve in the pond water return line. This valve was designated by the manufacturer to reduce the amount of water flowing through the trim cooler. This is not necessary in our application. There is some concern that the cooling fluid may cool the mechanical eqUipment too much when they are not operating or during very cold days. This issue will be addressed and the conclusion appended to this engineering note.

  6. Air Pollution, ATS555 Colorado State University

    E-Print Network [OSTI]

    Collett Jr., Jeffrey L.

    Air Pollution, ATS555 Colorado State University Fall 2014 Mondays and Wednesdays @ 4:00 ­ 5:30 Room://ramct.colostate.edu/) Textbooks: Air Pollution: Its Origin and Control, 3rd Edition, by Wark, Warner and Davis, Addison Wesley. Specific objectives include: 1. Develop an understanding of types and sources of air pollution. 2. Examine

  7. Condensation Risk in a Room with High Latent Load and Chilled Ceiling

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    proposed a new ventilation system with radiant cooling panel and air supplied from a liquid desiccant dehumidification system, which provided very dry supply air and chilled water for radiant cooling. This study usedCondensation Risk in a Room with High Latent Load and Chilled Ceiling Panel and with Air Supplied

  8. Thermal Inertia: Towards An Energy Conservation Room Management System (Technical report)

    E-Print Network [OSTI]

    Wang, Dan

    increasing attention to energy conservation around the world. The heating and air-conditioning systems-dissipated cool or heated air and conserve energy. We develop a green room management system with three main expenses of the heating or air-conditioning devices. Second, we build an energy-temperature correlation

  9. NATURAL CONVECTION IN ROOM GEOMETRIES

    SciTech Connect (OSTI)

    Gadgil, A.; Bauman, Fred; Kammerud, R.; Ruberg, K.

    1980-06-01T23:59:59.000Z

    Computer programs have been developed to numerically simulate natural convection in room geometries in two and three dimensions. The programs have been validated using published data from the literature, results from a full-scale experiment performed at Massachusetts Institute of Technology, and results from a small-scale experiment reported here. One of the computer programs has been used to study the influence of natural convection on the thermal performance of a single thermal zone in a direct-gain passive solar building. The results indicate that the building heating loads calculated by standard building energy analysis methods may be in error by as much as 50% as a result of their use of common assumptions regarding the convection processes which occur in an enclosure. It is also found that the convective heat transfer coefficients between the air and the enclosure surfaces can be substantially different from the values assumed in the standard building energy analysis methods, and can exhibit significant variations across a given surface.

  10. Method and apparatus for analog signal conditioner for high speed, digital x-ray spectrometer

    DOE Patents [OSTI]

    Warburton, William K. (1300 Mills St., Menlo Park, CA 94025); Hubbard, Bradley (Santa Cruz, CA)

    1999-01-01T23:59:59.000Z

    A signal processing system which accepts input from an x-ray detector-preamplifier and produces a signal of reduced dynamic range for subsequent analog-to-digital conversion. The system conditions the input signal to reduce the number of bits required in the analog-to-digital converter by removing that part of the input signal which varies only slowly in time and retaining the amplitude of the pulses which carry information about the x-rays absorbed by the detector. The parameters controlling the signal conditioner's operation can be readily supplied in digital form, allowing it to be integrated into a feedback loop as part of a larger digital x-ray spectroscopy system.

  11. Friedrich: ENERGY STAR Referral (SM18M30)

    Broader source: Energy.gov [DOE]

    DOE referred the matter of Friedrich room air conditioner model SM18M30 to the EPA for appropriate action after DOE testing showed that the model does not meet the ENERGY STAR specification.

  12. Projected Regional Impacts of Appliance Efficiency Standards for the U.S. Residential Sector

    E-Print Network [OSTI]

    Koomey, J.G.

    2010-01-01T23:59:59.000Z

    Air Conditioners, Water Heaters, Direct Heating Equipment,according to the type of water heater used in the home.Gas Room Central HP Water heater Showers Faucets Furnace X X

  13. CX-008759: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Information Operations & Research Center (IORC) Room E-6 Air Conditioner Unit Installation CX(s) Applied: B1.4 Date: 05/09/2012 Location(s): Idaho Offices(s): Idaho Operations Office

  14. EA-0819: Final Environmental Assessment

    Broader source: Energy.gov [DOE]

    Proposed Energy Conservation Standards for Eight Types of Consumer Products: Room Air Conditioners, Water Heaters, Direct Heating Equipment, Mobile Home Furnaces, Ranges and Ovens, Pool Heaters, Fluorescent Ballasts, and Television Sets

  15. Friedrich: ENERGY STAR Referral (SS14L10-E)

    Broader source: Energy.gov [DOE]

    DOE referred the matter of Friedrich room air conditioner SS14L10-E to the EPA for appropriate action after DOE testing showed that the model does not meet the ENERGY STAR specification.

  16. Goodman: Proposed Penalty (2012-CE-1509)

    Broader source: Energy.gov [DOE]

    DOE alleged in a Notice of Proposed Civil Penalty that Goodman Manufacturing Company, L.P., failed to certify a various room air conditioners as compliant with the applicable energy conservation standards.

  17. Goodman Manufacturing: Order (2012-CE-1509)

    Broader source: Energy.gov [DOE]

    DOE ordered Goodman Manufacturing Company L.P. to pay an $8,000 civil penalty after finding Goodman Manufacturing had failed to certify that certain room air conditioners comply with the applicable energy conservation standard.

  18. Energy Efficiency Indicators Methodology Booklet

    E-Print Network [OSTI]

    Sathaye, Jayant

    2010-01-01T23:59:59.000Z

    source) District heating Wood Biogas Charcoal Stove/ RoomHeating Television Refrigerator Freezer Washing Machine Air-Conditioner Fan Tubular fluorescent Compact fluorescent Halogen Kerosene lamp Wood Stove Biogas

  19. Haier: ENERGY STAR Referral (ESA3087)

    Broader source: Energy.gov [DOE]

    DOE referred Haier room air conditioner model ESA3087 to EPA, brand manager of the ENERGY STAR program, for appropriate action after DOE testing revealed that the model does not meet ENERGY STAR requirements.

  20. U.S. Building-Sector Energy Efficiency Potential

    E-Print Network [OSTI]

    Brown, Rich

    2008-01-01T23:59:59.000Z

    the technologies such as heat pump water heaters are stillheat pump water heater, horizontal axis clothes washer Best-heat pump efficiency Improved efficiency central and room air conditioners, variable speed RAC Reduced standby-loss electric resistance water heater,

  1. International Refrigeration: Proposed Penalty (2012-CE-1510)

    Broader source: Energy.gov [DOE]

    DOE alleged in a Notice of Proposed Civil Penalty that International Refrigeration Products failed to certify a various room air conditioners as compliant with the applicable energy conservation standards.

  2. International Refrigeration: Order (2012-CE-1510)

    Broader source: Energy.gov [DOE]

    DOE ordered International Refrigeration Products to pay an $8,000 civil penalty after finding International Refrigeration had failed to certify that certain room air conditioners comply with the applicable energy conservation standard.

  3. Exposure assessment of particulate matter air pollution before, during, and after the 2003 Southern California wildfires

    E-Print Network [OSTI]

    Wu, J; Winer, A M; Delfino, R J

    2006-01-01T23:59:59.000Z

    particulate air pollution data for an epidemiological studyOstra, B. , 1997. Air pollution and emergency room visitsJ. , 1994. Indoor air pollution and asthma: Results from a

  4. audiometric test rooms: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    audiometric test rooms First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Energy performance of air...

  5. Desiccant Enhanced Evaporative Air-Conditioning (DEVap): Evaluation of a New Concept in Ultra Efficient Air Conditioning

    SciTech Connect (OSTI)

    Kozubal, E.; Woods, J.; Burch, J.; Boranian, A.; Merrigan, T.

    2011-01-01T23:59:59.000Z

    NREL has developed the novel concept of a desiccant enhanced evaporative air conditioner (DEVap) with the objective of combining the benefits of liquid desiccant and evaporative cooling technologies into an innovative 'cooling core.' Liquid desiccant technologies have extraordinary dehumidification potential, but require an efficient cooling sink. DEVap's thermodynamic potential overcomes many shortcomings of standard refrigeration-based direct expansion cooling. DEVap decouples cooling and dehumidification performance, which results in independent temperature and humidity control. The energy input is largely switched away from electricity to low-grade thermal energy that can be sourced from fuels such as natural gas, waste heat, solar, or biofuels.

  6. Perfluorocarbon tracer method for air-infiltration measurements

    DOE Patents [OSTI]

    Dietz, R.N.

    1982-09-23T23:59:59.000Z

    A method of measuring air infiltration rates suitable for use in rooms of homes and buildings comprises the steps of emitting perfluorocarbons in the room to be measured, sampling the air containing the emitted perfluorocarbons over a period of time, and analyzing the samples at a laboratory or other facility.

  7. Mechanical Air Distribution and Interacting Relationships

    E-Print Network [OSTI]

    Tooley, J. J.; Moyer, N. A.

    1989-01-01T23:59:59.000Z

    .) duct system design 2.) homeowner interaction with the system 3.) how tight the house is and 4.) cleanliness of the blower, filter and evaporator coil. This combination can cause air pressure differences within the house from room to room...). The tighter the house the more drastic the pressures across exterior and interior partitions. Cleanliness of the blower, filter and evaporator coils also was found to be a contributor to the degree of pressure differences. This was due the lack of air...

  8. News Room | Argonne National Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    News Room Argonne Associate Laboratory Director for Energy and Global Security Mark Peters, left, signs a memorandum of understanding with Nadya Bliss, director of the Global...

  9. Central Air Conditioners","Heat Pumps","Individual Air Conditioners","District Chilled Water","Central Chillers","Packaged

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghurajiConventionalMississippi"site. If you need43 3.84LeaseProcess: Catalytic Reforming Catalytic4.

  10. Central Air Conditioners","Heat Pumps","Individual Air Conditioners","District Chilled Water","Central Chillers","Packaged

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghurajiConventionalMississippi"site. If you need43 3.84LeaseProcess: Catalytic Reforming Catalytic4.5.

  11. Effects of system cycling, evaporator airflow, and condenser coil fouling on the performance of residential split-system air conditioners

    E-Print Network [OSTI]

    Dooley, Jeffrey Brandon

    2005-02-17T23:59:59.000Z

    ????????????????????.. 63 Energy Efficiency Ratio (EER)???????????.. 65 Sensible Heat Factor (SHF)????????????? 66 Power Consumption???????????????... 67 Condenser Discharge Pressure and Temperature????... 69 Evaporator Suction Pressure...??????????. 76 Capacity????????????????????.. 78 Energy Efficiency Ratio (EER)???????????.. 81 Sensible Heat Factor (SHF)????????????.... 83 Power Consumption???????????????... 85 Condenser Discharge Pressure???????????... 86...

  12. PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976

    E-Print Network [OSTI]

    Dao, K.

    2010-01-01T23:59:59.000Z

    Road Springfield, Virginia 22161 Price: Printed Copy $5.50; Microfiche $2.25 LBL-5911 PERFORMANCE OF AN EXPERIMENTAL SOLAR-

  13. PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976

    E-Print Network [OSTI]

    Dao, K.

    2010-01-01T23:59:59.000Z

    to extrapolated data from Linde (pool boiling of 50 % NH 3 -ft area: 4 ft 0.584 inch rD, Linde hi-flux tubing Analyzer (ring packing 16" diameter Linde hi-flux tubing XBL 757-3558

  14. Simulation of Dehumidification Characteristics of High Efficiency Residential Central Air-Conditioners in Hot and Humid Climates

    E-Print Network [OSTI]

    Katipamula, S.; O'Neal, D.; Somasundram, S.

    1988-01-01T23:59:59.000Z

    ) thermostat set point and dead band, and (ill) sizing of unit relative to the design load of the residence. The units are evaluated on their ability to maintain conditions in the ASHRAE comfort zone in a typical residence in Houston area. The units...

  15. NREL Demonstrates Game-Changing Air Conditioner Technology (Fact Sheet), Highlights in Research & Development, NREL (National Renewable Energy Laboratory)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit | National Nuclear SecurityJune

  16. NREL Solves Residential Window Air Conditioner Performance Limitations (Fact Sheet), Highlights in Research & Development, NREL (National Renewable Energy Laboratory)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit | National Nuclear13 Denver West Parkway Golden, CO

  17. PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976

    E-Print Network [OSTI]

    Dao, K.

    2010-01-01T23:59:59.000Z

    rates were calibrated The heat inputs to the generator (qG)of chilled water, lbs/hr heat input from hot water, Btu/hrof Run 20e. Q cw P T heat input from chilled water, Btu/hr

  18. An Evaluation of the Effects of Refrigerant Charge on a Residential Central Air Conditioner with Orifice Expansion

    E-Print Network [OSTI]

    O'Neal, D. L.; Ramsey, C. J.; Farzad, M.

    1989-01-01T23:59:59.000Z

    had one row of tubes with spine fins spaced at 20 per inch. The face area of the coil was 20.94 ft with refrigerant tube sizes of 3/8". The outdoor fan was located on the top of the outdoor coil. The fan specifications are given in Table 2.... 2.5 Table 2.1 - Fan Specification Refrigerant Side A schematic of the refrigerant circuit is shown in Figure 2.3. Refrigerant pressures were monitored at the 6 points shown with the use of 0-300 psig pressure transducers. To accurately measure...

  19. PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976

    E-Print Network [OSTI]

    Dao, K.

    2010-01-01T23:59:59.000Z

    U. THW . In T HW out TSS Q UW (Btu/hr) LiT m U IllWS (Ibs/OF) (OF) (OF) (OF) (OF) (Btu/hr ft2.F 20A 20C 19A lIS 17BU Run number m HW (1bs/hr) (Btu/hr- ft2_F) mS == ! z(nlWS+

  20. Understanding Energy Impacts of Oversized Air Conditioners (Fact Sheet), NREL Highlights, Research & Development, NREL (National Renewable Energy Laboratory)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of ScienceandMesa del SolStrengthening aTurbulence mayUndergraduate ProgramCenter |

  1. A fundamentally new approach to air-cooled heat exchangers.

    SciTech Connect (OSTI)

    Koplow, Jeffrey P.

    2010-01-01T23:59:59.000Z

    We describe breakthrough results obtained in a feasibility study of a fundamentally new architecture for air-cooled heat exchangers. A longstanding but largely unrealized opportunity in energy efficiency concerns the performance of air-cooled heat exchangers used in air conditioners, heat pumps, and refrigeration equipment. In the case of residential air conditioners, for example, the typical performance of the air cooled heat exchangers used for condensers and evaporators is at best marginal from the standpoint the of achieving maximum the possible coefficient of performance (COP). If by some means it were possible to reduce the thermal resistance of these heat exchangers to a negligible level, a typical energy savings of order 30% could be immediately realized. It has long been known that a several-fold increase in heat exchanger size, in conjunction with the use of much higher volumetric flow rates, provides a straight-forward path to this goal but is not practical from the standpoint of real world applications. The tension in the market place between the need for energy efficiency and logistical considerations such as equipment size, cost and operating noise has resulted in a compromise that is far from ideal. This is the reason that a typical residential air conditioner exhibits significant sensitivity to reductions in fan speed and/or fouling of the heat exchanger surface. The prevailing wisdom is that little can be done to improve this situation; the 'fan-plus-finned-heat-sink' heat exchanger architecture used throughout the energy sector represents an extremely mature technology for which there is little opportunity for further optimization. But the fact remains that conventional fan-plus-finned-heat-sink technology simply doesn't work that well. Their primary physical limitation to performance (i.e. low thermal resistance) is the boundary layer of motionless air that adheres to and envelops all surfaces of the heat exchanger. Within this boundary layer region, diffusive transport is the dominant mechanism for heat transfer. The resulting thermal bottleneck largely determines the thermal resistance of the heat exchanger. No one has yet devised a practical solution to the boundary layer problem. Another longstanding problem is inevitable fouling of the heat exchanger surface over time by particulate matter and other airborne contaminants. This problem is especially important in residential air conditioner systems where often little or no preventative maintenance is practiced. The heat sink fouling problem also remains unsolved. The third major problem (alluded to earlier) concerns inadequate airflow to heat exchanger resulting from restrictions on fan noise. The air-cooled heat exchanger described here solves all of the above three problems simultaneously. The 'Air Bearing Heat Exchanger' provides a several-fold reduction in boundary layer thickness, intrinsic immunity to heat sink fouling, and drastic reductions in noise. It is also very practical from the standpoint of cost, complexity, ruggedness, etc. Successful development of this technology is also expected to have far reaching impact in the IT sector from the standpointpoint of solving the 'Thermal Brick Wall' problem (which currently limits CPU clocks speeds to {approx}3 GHz), and increasing concern about the the electrical power consumption of our nation's information technology infrastructure.

  2. Magnetic Refrigeration Technology for High Efficiency Air Conditioning

    SciTech Connect (OSTI)

    Boeder, A; Zimm, C

    2006-09-30T23:59:59.000Z

    Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate heat exchangers or oil distribution issues found in traditional vapor compression systems.

  3. Calendar Year 2007 Program Benefits for U.S. EPA Energy Star Labeled Products: Expanded Methodology

    E-Print Network [OSTI]

    Sanchez, Marla

    2010-01-01T23:59:59.000Z

    Air Conditioners and Air Source Heat Pumps. Unpublishedpackage central air conditioners and heat pumps, rated atManufacturers air source heat pump American Society of

  4. Columbia University Hazardous Waste Room Inspection Report

    E-Print Network [OSTI]

    Jia, Songtao

    Storage Area Hazardous Waste Room Inspection Report Location: Bldg. Room: Date: Inspected ByColumbia University Hazardous Waste Room Inspection Report Flammable Storage Area Lack Pack always closed while holding hazardous wastes? Comment: 12. Are containers labeled? Date

  5. Nuclear reactor control room construction

    DOE Patents [OSTI]

    Lamuro, R.C.; Orr, R.

    1993-11-16T23:59:59.000Z

    A control room for a nuclear plant is disclosed. In the control room, objects labelled 12, 20, 22, 26, 30 in the drawing are no less than four inches from walls labelled 10.2. A ceiling contains cooling fins that extend downwards toward the floor from metal plates. A concrete slab is poured over the plates. Studs are welded to the plates and are encased in the concrete. 6 figures.

  6. Nuclear reactor control room construction

    DOE Patents [OSTI]

    Lamuro, Robert C. (Pittsburgh, PA); Orr, Richard (Pittsburgh, PA)

    1993-01-01T23:59:59.000Z

    A control room 10 for a nuclear plant is disclosed. In the control room, objects 12, 20, 22, 26, 30 are no less than four inches from walls 10.2. A ceiling 32 contains cooling fins 35 that extend downwards toward the floor from metal plates 34. A concrete slab 33 is poured over the plates. Studs 36 are welded to the plates and are encased in the concrete.

  7. Thermal decay in underfloor air distribution (UFAD) systems: Fundamentals and influence on system performance

    E-Print Network [OSTI]

    Lee, Kwang Ho; Schiavon, Stefano; Bauman, Fred; Webster, Tom

    2012-01-01T23:59:59.000Z

    a comparison of room cooling load and supply air to roomtemperatures, cooling load profiles, supply airflow rate,water cooling coil, hot water heating coil and supply fan.

  8. Control of Computer Room Air Conditioning using IT Equipment Sensors

    E-Print Network [OSTI]

    Bell, Geoffrey C.

    2010-01-01T23:59:59.000Z

    to control the cooling system in the data center, energyfor input to the data center cooling system devices. Goal 2:for input to the data center cooling system devices. See

  9. Control of Computer Room Air Conditioning using IT Equipment Sensors

    E-Print Network [OSTI]

    Bell, Geoffrey C.

    2010-01-01T23:59:59.000Z

    graphics that allowed facility operators to choose which server temperature data points were used for control.graphics that allowed facility operators to choose which server temperature data points were used for control.

  10. Analysis of Cold Air Distribution System in an Office Building by the Numerical Simulation Method

    E-Print Network [OSTI]

    Jian, Y.; Li, D.; Xu, H.; Ma, X.

    2006-01-01T23:59:59.000Z

    Numerical simulation is carried out in this paper to calculate indoor air patterns, which include angles of inlet direction and induced ratios in a typical official room. According to the simulation results, the indoor air distribution and indoor...

  11. E-Print Network 3.0 - apheis project air Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to supply rooms with air that is "conditioned"--that is, heated or cooled... by the heating, ventilation, and air conditioning (HVAC) equipment--and to recirculate or return...

  12. Study of Air Infiltration Energy Consumption

    E-Print Network [OSTI]

    Liu, Mingsheng

    SYSTEMATIC ERROR DUE TO THE STEADY-STATE COMBINED MODELS 127 SIMULATION AND NUMERICAL RESULTS 141 APPLICATION 150 SUMMARy 157 METHODOLOGy 158 DIFFERENTIAL EQUATION 159 DISCRETIZATION OF THE DIFFERENTIAL EQUATION 161 EXTERNAL NODE EQUATIONS 164... temperature. Clearly, the room heater does not need to heat the air from the outside temperature to the room temperature because it has already captured part of the conduction heat flowing through the wall. To properly estimate house energy consumption...

  13. A Smart Logic for Conference Room Terminal Box of Single Duct VAV System 

    E-Print Network [OSTI]

    Yu, Y.; Xu, K.; Cho, Y.; Liu, M.

    2007-01-01T23:59:59.000Z

    A SMART LOGIC FOR CONFERENCE ROOM TERMINAL BOX OF SINGLE DUCT VAV SYSTEM Yuebin Yu Ke Xu YoungHum Cho Mingsheng Liu Graduate Student Graduate Student Graduate Student Professor of Architectural... in the conference room. The detailed calculation example for the parameters and the energy saving performance analysis based on air modeling are given in the other paper (Yuebin Yu, et al. 2007). The main principles of the operation logic are stated as follows...

  14. Building Name Room Support By

    E-Print Network [OSTI]

    Mohaghegh, Shahab

    Building Name Room Technology Classroom? Technology Support By: Phone Number: Contact Name: Agricultural Sciences Building G29 Standard iDC 304-293-2832 n/a Agricultural Sciences Building G31 Standard iDC 304-293-2832 n/a Agricultural Sciences Building G101 Standard iDC 304-293-2832 n/a Agricultural

  15. Master Clock in Laser Room

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Master Clock in Laser Room Master clock MITEQ MN XTO-02-81.6-G-T-20P SN 180585 1 2 3 4 To YAG SYSTEM CLOCK To YAG SYSTEM C 975 81.6 MHz To MEZZ SPARE J17 J15 Multiplier...

  16. Calendar Year 2009 Program Benefits for ENERGY STAR Labeled Products

    E-Print Network [OSTI]

    Homan, Gregory K

    2011-01-01T23:59:59.000Z

    covers central air conditioners and heat pumps with up toconditioning, ASHP = air source heat pump, HP = heat pump,Conditioners and Air-Source Heat Pumps • Commercial Fryers •

  17. Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products

    E-Print Network [OSTI]

    Homan, GregoryK

    2010-01-01T23:59:59.000Z

    covers central air conditioners and heat pumps with up toconditioning, ASHP = air source heat pump, HP = heat pump,Conditioners and Air-Source Heat Pumps • Commercial Fryers •

  18. Heat transfer pathways in underfloor air distribution (UFAD) systems

    E-Print Network [OSTI]

    Bauman, F.; Jin, H.; Webster, T.

    2006-01-01T23:59:59.000Z

    is little radiative heat transfer and little impact on thereturn air extrac- tion and heat transfer to the plenum. ItUFAD is often used and heat transfer out of the room through

  19. Compressed Air System Analysis and Retrofit for Energy Savings 

    E-Print Network [OSTI]

    Harding, C.; Nutter, D.

    2014-01-01T23:59:59.000Z

    . Therefore, high quality compressed air is a key component of that objective. The compressed air used in the manufacturing process at this facility is held to ISO (International Organization for Standardization) class 2 air quality standards.... The compressor room contained two wet storage tanks, with a total capacity of 1,800 gallons. A heated desiccant dryer with associated filters was also located in the compressor room. Dry air was sent into the plant to a 2,000 gallon dry storage tank, which...

  20. Computer codes for evaluation of control room habitability (HABIT)

    SciTech Connect (OSTI)

    Stage, S.A. [Pacific Northwest Lab., Richland, WA (United States)

    1996-06-01T23:59:59.000Z

    This report describes the Computer Codes for Evaluation of Control Room Habitability (HABIT). HABIT is a package of computer codes designed to be used for the evaluation of control room habitability in the event of an accidental release of toxic chemicals or radioactive materials. Given information about the design of a nuclear power plant, a scenario for the release of toxic chemicals or radionuclides, and information about the air flows and protection systems of the control room, HABIT can be used to estimate the chemical exposure or radiological dose to control room personnel. HABIT is an integrated package of several programs that previously needed to be run separately and required considerable user intervention. This report discusses the theoretical basis and physical assumptions made by each of the modules in HABIT and gives detailed information about the data entry windows. Sample runs are given for each of the modules. A brief section of programming notes is included. A set of computer disks will accompany this report if the report is ordered from the Energy Science and Technology Software Center. The disks contain the files needed to run HABIT on a personal computer running DOS. Source codes for the various HABIT routines are on the disks. Also included are input and output files for three demonstration runs.

  1. NREL Provides Guidance to Improve Air Mixing and Thermal Comfort in Homes (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-02-01T23:59:59.000Z

    NREL research determines optimal HVAC system design for proper air mixing and thermal comfort in homes. As U.S. homes become more energy efficient, heating, ventilation, and cooling (HVAC) systems will be downsized, and the air flow volumes required to meet heating and cooling loads may be too small to maintain uniform room air mixing-which can affect thermal comfort. Researchers at the National Renewable Energy Laboratory (NREL) evaluated the performance of high sidewall air supply inlets and confirmed that these systems can achieve good air mixing and provide suitable comfort levels for occupants. Using computational fluid dynamics modeling, NREL scientists tested the performance of high sidewall supply air jets over a wide range of parameters including supply air temperature, air velocity, and inlet size. This technique uses the model output to determine how well the supply air mixes with the room air. Thermal comfort is evaluated by monitoring air temperature and velocity in more than 600,000 control volumes that make up the occupied zone of a single room. The room has an acceptable comfort level when more than 70% of the control volumes meet the comfort criteria on both air temperature and velocity. The study shows that high sidewall supply air jets achieve uniform mixing in a room, which is essential for providing acceptable comfort levels. The study also provides information required to optimize overall space conditioning system design in both heating and cooling modes.

  2. Energy Integration Visualization Room (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-08-01T23:59:59.000Z

    This two-page fact sheet describes the new Energy Integration Visualization Room in the ESIF and talks about some of the capabilities and unique visualization features of the the room.

  3. The Live Room : transducing resonant architectures

    E-Print Network [OSTI]

    Bain, Mark, 1966-

    1998-01-01T23:59:59.000Z

    The Live Room is a temporary site specific installation presented in building N 51, room 117 on the MIT campus on May 7, 1998 and concluded on June 10, 1998. Using small acoustic intensifying equipment which mount directly ...

  4. Residence Hall & Furnished

    E-Print Network [OSTI]

    Polly, David

    Air Conditioner Units . . . . . . . . . . . . . . . . . 7 Bunking/Lofting Beds & Air Conditioning . . . . . . . . . . . . 9 Mailing Address

  5. Novel room temperature ferromagnetic semiconductors

    SciTech Connect (OSTI)

    Gupta, Amita

    2004-11-01T23:59:59.000Z

    Today's information world, bits of data are processed by semiconductor chips, and stored in the magnetic disk drives. But tomorrow's information technology may see magnetism (spin) and semiconductivity (charge) combined in one 'spintronic' device that exploits both charge and 'spin' to carry data (the best of two worlds). Spintronic devices such as spin valve transistors, spin light emitting diodes, non-volatile memory, logic devices, optical isolators and ultra-fast optical switches are some of the areas of interest for introducing the ferromagnetic properties at room temperature in a semiconductor to make it multifunctional. The potential advantages of such spintronic devices will be higher speed, greater efficiency, and better stability at a reduced power consumption. This Thesis contains two main topics: In-depth understanding of magnetism in Mn doped ZnO, and our search and identification of at least six new above room temperature ferromagnetic semiconductors. Both complex doped ZnO based new materials, as well as a number of nonoxides like phosphides, and sulfides suitably doped with Mn or Cu are shown to give rise to ferromagnetism above room temperature. Some of the highlights of this work are discovery of room temperature ferromagnetism in: (1) ZnO:Mn (paper in Nature Materials, Oct issue, 2003); (2) ZnO doped with Cu (containing no magnetic elements in it); (3) GaP doped with Cu (again containing no magnetic elements in it); (4) Enhancement of Magnetization by Cu co-doping in ZnO:Mn; (5) CdS doped with Mn, and a few others not reported in this thesis. We discuss in detail the first observation of ferromagnetism above room temperature in the form of powder, bulk pellets, in 2-3 mu-m thick transparent pulsed laser deposited films of the Mn (<4 at. percent) doped ZnO. High-resolution transmission electron microscopy (HRTEM) and electron energy loss spectroscopy (EELS) spectra recorded from 2 to 200nm areas showed homogeneous distribution of Mn substituting for Zn a 2+ state in the ZnO lattice. Ferromagnetic Resonance (FMR) technique is used to confirm the existence of ferromagnetic ordering at temperatures as high as 425K. The ab initio calculations were found to be consistent with the observation of ferromagnetism arising from fully polarized Mn 2+ state. The key to observed room temperature ferromagnetism in this system is the low temperature processing, which prevents formation of clusters, secondary phases and the host ZnO from becoming n-type. The electronic structure of the same Mn doped ZnO thin films studied using XAS, XES and RIXS, revealed a strong hybridization between Mn 3d and O 2p states, which is an important characteristic of a Dilute magnetic Semiconductor (DMS). It is shown that the various processing conditions like sintering temperature, dopant concentration and the properties of precursors used for making of DMS have a great influence on the final properties. Use of various experimental techniques to verify the physical properties, and to understand the mechanism involved to give rise to ferromagnetism is presented. Methods to improve the magnetic moment in Mn doped ZnO are also described. New promising DMS materials (such as Cu doped ZnO are explored). The demonstrated new capability to fabricate powder, pellets, and thin films of room temperature ferromagnetic semiconductors thus makes possible the realization of a wide range of complex elements for a variety of new multifunctional phenomena related to Spintronic devices as well as magneto-optic components.

  6. Library Reserved Room Policy All Meeting Spaces

    E-Print Network [OSTI]

    Mather, Patrick T.

    Library Reserved Room Policy All Meeting Spaces Room reservation To make a reservation for any Library meeting space, complete the room reservation form at http://library.syr.edu/services/space/form-findroom.php. In order to provide equitable access to library spaces, the Library may impose limitations on frequency

  7. Multisurface Interaction in the WILD Room

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    - 1 - Multisurface Interaction in the WILD Room Michel Beaudouin-Lafon, Stéphane Huot, Mathieu University Abstract The WILD room (wall-sized interaction with large datasets) serves as a testbed. (2012), "Multisurface Interaction in the WILD Room", IEEE Computer, vol 45, nº 4, pp. 48-56. DOI

  8. Electronic Docket Room (e-Docket Room) | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube|6721 Federal Register / Vol.6:Energy|Electrifying YourElectronic Docket Room

  9. Market and behavioral barriers to energy efficiency: A preliminary evaluation of the case for tariff financing in California

    E-Print Network [OSTI]

    Fujita, K. Sydny

    2012-01-01T23:59:59.000Z

    for central air conditioner replacements Efficiency level 20state, replacement of outdated central air conditioners orAir Conditioners .. 15   Furnaces 16   Water heaters .. 17   Potential savings from rental housing unit water heater replacements .

  10. CONTROL SYSTEM FOR SOLAR HEATING and COOLING

    E-Print Network [OSTI]

    Dols, C.

    2010-01-01T23:59:59.000Z

    ~O"')4 REFERENCES The air conditioner work is the subject ofAmmonia-Water Absorption Air Conditioner", by M. Simmons, R.water absorption air conditioner, (1) and the establishment

  11. BPM Motors in Residential Gas Furnaces: What are the Savings?

    E-Print Network [OSTI]

    Lutz, James; Franco, Victor; Lekov, Alex; Wong-Parodi, Gabrielle

    2006-01-01T23:59:59.000Z

    Comfort Series 13 Air Conditioner with Puron Refrigerant.for new houses with 3.5 ton air-conditioners from a study ofblower use by the air conditioner and stand-by power.

  12. TWOZONE USERS MANUAL

    E-Print Network [OSTI]

    Gadgil, Ashok J.

    2010-01-01T23:59:59.000Z

    9. Sizing chart for air conditioner. z ~::~~OOOOOOOOOOOOOOOOoperation of either an air conditioner and/or an evaporativecooler, improved air-conditioner algorithm, ability to read

  13. TWOZONE USERS MANUAL

    E-Print Network [OSTI]

    Gadgil, Ashok J.

    2008-01-01T23:59:59.000Z

    9. Sizing chart for air conditioner. z ~::~~OOOOOOOOOOOOOOOOoperation of either an air conditioner and/or an evaporativecooler, improved air-conditioner algorithm, ability to read

  14. Heating remote rooms in passive solar buildings

    SciTech Connect (OSTI)

    Balcomb, J.D.

    1981-01-01T23:59:59.000Z

    Remote rooms can be effectively heated by convection through a connecting doorway. A simple steady-state equation is developed for design purposes. Validation of a dynamic model is achieved using data obtained over a 13-day period. Dynamic effects are investigated using a simulation analysis for three different cases of driving temperature; the effect is to reduce the temperature difference between the driving room and the remote room compared to the steady-state model. For large temperature swings in the driving room a strategy which uses the intervening door in a diode mode is effective. The importance of heat-storing mass in the remote room is investigated.

  15. Last Updated 8/12/2013 Page 1 of 2 Meeting Room 2 Meeting Room 3 Meeting Room 4 Meeting Room 5 Meeting Room 6

    E-Print Network [OSTI]

    Minnesota, University of

    Meeting Room 6 8:00 a.m.-12:00 noon Intro to LID Rainwater Harvesting 1:00-5:00 p.m. Advances in Design Strategies for Achieving Water Quality Goals Publications and Approaches for Mainstreaming LID LID Modeling Cities Light Rail Monitoring Bioretention and Rainwater Harvesting Systems Urban Trees as a LID Source

  16. Molecular dynamics simulations of the nano-scale room-temperature oxidation of aluminum single crystals

    E-Print Network [OSTI]

    Southern California, University of

    films that form on aluminum and aluminum alloys in air protect the surface against further oxidationMolecular dynamics simulations of the nano-scale room-temperature oxidation of aluminum single Abstract The oxidation of aluminum single crystals is studied using molecular dynamics (MD) simulations

  17. Determination of Binding Constants of Cyclodextrins in Room-Temperature Ionic Liquids

    E-Print Network [OSTI]

    Reid, Scott A.

    unique chemical and physical properties, including being air and moisture stable, a high solubility power with supercritical fluid CO2;9-11 (4) electrochemical reactions;12,13 and (5) as a medium for enzymatic reactions.14Determination of Binding Constants of Cyclodextrins in Room-Temperature Ionic Liquids by Near

  18. Electronic Parts and Services Engineering Student Work Lab: Engineering East (EE), Room 205A

    E-Print Network [OSTI]

    Fernandez, Eduardo

    Potentiometers (Pots) Motors, Servos, Solenoids, Fans, Air Batteries And Battery Holders Relays Cabinet 3 (Empty Manager, 561.297.3416, vansant@fau.edu Room Layout Cabinet 1 Battery Holders Crystals Crystals Assorted Standoffs Plastic Washers/Screws Washers Miscellaneous Hardware, Metal Screws Nuts Brackets

  19. Energy performance of air distribution systems part II: room air stratification full scale testing

    E-Print Network [OSTI]

    Webster, Tom; Lukaschek, Wolfgang; Dickeroff, Darryl; Bauman, Fred

    2007-01-01T23:59:59.000Z

    activated the solar array in the environmental chamber. ThisEquipment Warehouse Environmental Chamber (Quartz lamp solarthe solar array was installed in the environmental chamber (

  20. Energy performance of air distribution systems part II: room air stratification full scale testing

    E-Print Network [OSTI]

    Webster, Tom; Lukaschek, Wolfgang; Dickeroff, Darryl; Bauman, Fred

    2007-01-01T23:59:59.000Z

    wall: Door @ South wall: [Btu*h -1 *ft -2 *°F -1 ] [W(m²K)]plenum top: SA plenum bottom: [Btu*h -1 *°F -1 ] [W °K -1 ]and U-value of 2.8 W/(m²K) (0.5 Btu/(hft²°F)). However, this

  1. DOE Institutes Enforcement Action Against AeroSys, Inc. for Failure...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard...

  2. Impacts of Imported Liquefied Natural Gas on Residential Appliance Components: Literature Review

    E-Print Network [OSTI]

    Lekov, Alex

    2010-01-01T23:59:59.000Z

    on New FVIR Water Heaters." Retrieved 04/17/2009, 2009, fromAir Conditioners, Water Heaters, Direct Heating Equipment,Air Conditioners, Water Heaters, Direct Heating Equipment,

  3. Laboratory Performance Testing of Residential Window Mounted...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Key Issues High-Efficiency Window Air Conditioners - Building America Top Innovation 2014-05-05 Issuance: Test Procedure for Portable Air Conditioners; Notice of Data Availability...

  4. FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH

    E-Print Network [OSTI]

    Lesieutre, Bernard

    2013-01-01T23:59:59.000Z

    Air Conditioner Testing in WECC,” IEEE Power  Engineering Air Conditioner Modeling, WECC Load Modeling Task  Force in power system studies: WECC progress update,? Power and 

  5. Page 1 of 3 Radiogram No. 1679u Form 24 for 03/02/2013

    E-Print Network [OSTI]

    Subsystem Preventive Maintenance, Group E FGB 2 Fan Cleaning Inspection of Air Conditioner Inspection Inspection of Air Conditioner Inspection and Cleaning of Auxiliary Computer System () Laptops

  6. Cascade Reverse Osmosis Air Conditioning System: Cascade Reverse Osmosis and the Absorption Osmosis Cycle

    SciTech Connect (OSTI)

    None

    2010-09-01T23:59:59.000Z

    BEETIT Project: Battelle is developing a new air conditioning system that uses a cascade reverse osmosis (RO)-based absorption cycle. Analyses show that this new cycle can be as much as 60% more efficient than vapor compression, which is used in 90% of air conditioners. Traditional vapor-compression systems use polluting liquids for a cooling effect. Absorption cycles use benign refrigerants such as water, which is absorbed in a salt solution and pumped as liquid—replacing compression of vapor. The refrigerant is subsequently separated from absorbing salt using heat for re-use in the cooling cycle. Battelle is replacing thermal separation of refrigerant with a more efficient reverse osmosis process. Research has shown that the cycle is possible, but further investment will be needed to reduce the number of cascade reverse osmosis stages and therefore cost.

  7. Theoretical Study of a Novel Control Method of VAV Air-conditioning System Based on MATLAB

    E-Print Network [OSTI]

    Shi, Z.; Hu, S.; Wang, G.; Li, A.

    2006-01-01T23:59:59.000Z

    The main purpose of this study is to put forward a novel nonlinear feedback control strategy on controlling indoor air temperature by variable air volume. A dynamic model of a typical room for a VAV air-conditioning system is established...

  8. STATE OF CALIFORNIA --NATURAL RESOURCES AGENCY ARNOLD SCHWARZENEGGER, Governor CALIFORNIA ENERGY COMMISSION

    E-Print Network [OSTI]

    · Dishwashers · Room Air Conditioners The closure of the rebate offer period for these appliance categories, Ventilating, and Air Conditioning (HVAC) Units until an official closure notice for those two categories the replacement of inefficient residential appliances with new energy efficient residential appliances

  9. STATE OF CALIFORNIA --THE NATURAL RESOURCES AGENCY ARNOLD SCHWARZENEGGER, Governor CALIFORNIA ENERGY COMMISSION

    E-Print Network [OSTI]

    for refrigerators, freezers, clothes washers, dishwashers and room air conditioners closed on December 6, 2010 for the following appliance categories will close on December 31, 2010: · Heating, Ventilating and Air Conditioning Program for #12;California that provides rebates to encourage the replacement of inefficient residential

  10. STATE OF CALIFORNIA --THE NATURAL RESOURCES AGENCY ARNOLD SCHWARZENEGGER, Governor CALIFORNIA ENERGY COMMISSION

    E-Print Network [OSTI]

    · Dishwashers · Room Air Conditioners Ending the rebate offer period for these appliance categories, Ventilating, and Air Conditioning Units until an official closure notice is issued by the Committee. #12;The Program for California that provides rebates to encourage the replacement of inefficient residential

  11. Physical Makeup of the DCO Interesting Statistics

    E-Print Network [OSTI]

    aisle) up to 90ºF (32ºC) · Battery power for 4 minute shutdown PUMP ROOM · Redundant heat exchangers and humidity of the building's fresh air as supplied to the DCO · Over the last year, temperature remained nearly constant · Humidity was controlled by the DCO air conditioners at all times during the year

  12. Utrecht University's High Potential Programme Making Room

    E-Print Network [OSTI]

    Utrecht, Universiteit

    Utrecht University's High Potential Programme Making Room for Talent 2 #12;Making Room for Talent Utrecht University has a worldwide reputation for excellence in research across a broad range. This is why in 2003 Utrecht University created the High Potential Programme, an incentive scheme which gives

  13. Also Known As (Room or Building)

    E-Print Network [OSTI]

    Mottram, Nigel

    Room No. Also Known As (Room or Building) Hearing Assistance Type 702 InfraRed 704 InfraRed 706 Smith Building Adam Smith Building Adam Smith Building Adam Smith Building Adam Smith Building Adam Smith Building Adam Smith Building Adam Smith Building Adam Smith Building Adam Smith Building Adam

  14. Topological Insulators at Room Temperature

    SciTech Connect (OSTI)

    Zhang, Haijun; /Beijing, Inst. Phys.; Liu, Chao-Xing; /Tsinghua U., Beijing; Qi, Xiao-Liang; /Stanford U., Phys. Dept.; Dai, Xi; Fang, Zhong; /Beijing, Inst. Phys.; Zhang, Shou-Cheng; /Stanford U., Phys. Dept.

    2010-03-25T23:59:59.000Z

    Topological insulators are new states of quantum matter with surface states protected by the time-reversal symmetry. In this work, we perform first-principle electronic structure calculations for Sb{sub 2}Te{sub 3}, Sb{sub 2}Se{sub 3}, Bi{sub 2}Te{sub 3} and Bi{sub 2}Se{sub 3} crystals. Our calculations predict that Sb{sub 2}Te{sub 3}, Bi{sub 2}T e{sub 3} and Bi{sub 2}Se{sub 3} are topological insulators, while Sb{sub 2}Se{sub 3} is not. In particular, Bi{sub 2}Se{sub 3} has a topologically non-trivial energy gap of 0.3eV , suitable for room temperature applications. We present a simple and unified continuum model which captures the salient topological features of this class of materials. These topological insulators have robust surface states consisting of a single Dirac cone at the {Lambda} point.

  15. Los Alamos test-room results

    SciTech Connect (OSTI)

    McFarland, R.D.; Balcomb, J.D.

    1982-01-01T23:59:59.000Z

    Fourteen Los Alamos test rooms have been operated for several years; this paper covers operation during the winters of 1980-81 and 1981-82. Extensive data have been taken and computer analyzed to determine performance parameters such as efficiency, solar savings fraction, and comfort index. The rooms are directly comparable because each has the same net coefficient and solar collection area and thus the same load collector ratio. Configurations include direct gain, unvented Trombe walls, water walls, phase change walls, and two sunspace geometries. Strategies for reducing heat loss include selective surfaces, two brands of superglazing windows, a heat pipe system, and convection-suppression baffles. Significant differences in both backup heat and comfort are observed among the various rooms. The results are useful, not only for direct room-to-room comparisons, but also to provide data for validation of computer simulation programs.

  16. Electric, Gas, and Electric/Gas Energy Options for Cold-Air HVAC Systems 

    E-Print Network [OSTI]

    Meckler, G.

    1989-01-01T23:59:59.000Z

    is distributed at 53" to 58OF from the central plant via integrated sprinkler piping. FICUs, illustrated in Figure 1, sensibly cool recirculated air as required, mix it with the 40°F ventilation air, and supply the mixed air at a constant volume. Figure 1.... Key: 80 1. Outside air enlaring enthalpy wheel, 91'FDE. 76'FWB. 2. Outside air leaving enlhalpy wheel. BI'FDB, 68qr. 3. Primary air leaving supply fan. 8SFDB. 68gr. 4. Primary air leaving ice cail. 4UFDB. 36qr.. sat. 5, Room condition. 7SFDE. 4O...

  17. Synchronous Programs Testing Language Mouna TKA Mnad1

    E-Print Network [OSTI]

    Boyer, Edmond

    of the language Let's consider the following simple reactive program, an air-conditioner controller. The program inputs are: onOff (Boolean: true when the user pushes the On-Off button of the air-conditioner), Tamb of the air-conditioner ) and Tout (integer: indicates the temperature of the air that the air-conditioner

  18. Air Quality: Construction Project Air Permit Requirements

    E-Print Network [OSTI]

    Wechsler, Risa H.

    Air Quality: Construction Project Air Permit Requirements Department: Chemical and General Safety Program: Air Quality Owner: Program Manager Authority: ES&H Manual, Chapter 30, Air Quality1 All manager or operator must submit the completed form to the air quality program manager before the project

  19. Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems

    E-Print Network [OSTI]

    Wetter, Michael

    2010-01-01T23:59:59.000Z

    Austria, September 2006. Modelica As- sociation and Arsenalsystems. The ?exibility of Modelica has been T room in [° C]lss. AirConditioning - a Modelica li- o brary for dynamic

  20. Optimal Terminal Box Control for Single Duct Air-Handling Units

    E-Print Network [OSTI]

    Cho, Y.; Vondal, J.; Wang, G.; Liu, M.

    2006-01-01T23:59:59.000Z

    Terminal boxes maintain room temperature by modulating supply air temperature and airflow in building HVAC systems. Terminal boxes with conventional control sequences often supply inadequate airflow to a conditioned space, resulting in occupant...

  1. Training Room Equipment Instructions Projector and TV Display

    E-Print Network [OSTI]

    Crawford, T. Daniel

    Training Room Equipment Instructions Projector and TV Display The control panel on the wall are connected to a training room computer and room is equipped with a keyboard, mouse and clicker. Connect USB

  2. Environmental color for pediatric patient room design

    E-Print Network [OSTI]

    Park, Jin Gyu

    2009-05-15T23:59:59.000Z

    Color has a large impact on our psychological and physiological responses. This study examines the value of color as a component in a healing environment for pediatric patient rooms by measuring color preferences among healthy children, pediatric...

  3. The Advanced Photon Source main control room

    SciTech Connect (OSTI)

    Pasky, S.

    1998-07-01T23:59:59.000Z

    The Advanced Photon Source at Argonne National Laboratory is a third-generation light source built in the 1990s. Like the machine itself, the Main Control Room (MCR) employs design concepts based on today`s requirements. The discussion will center on ideas used in the design of the MCR, the comfort of personnel using the design, and safety concerns integrated into the control room layout.

  4. Environmental effect on room-temperature ductility of isothermally forged TiAl-base alloys

    SciTech Connect (OSTI)

    Nakamura, Morihiko; Hashimoto, Kenki (National Research Inst. for Metals, Tokyo (Japan)); Itoh, Naoyuki (Nippon Steel Corp., Chiba (Japan)); Tsujimoto, Tokuzo (Ibaraki Univ. (Japan). Faculty of Engineering); Suzuki, Toshiyuki (Kougakuin Univ., Tokyo (Japan))

    1994-02-01T23:59:59.000Z

    Isothermally forged TiAl-base alloy (Al-rich, Mn-containing, and Cr-containing TiAl) were heat-treated in various conditions, and equiaxed grain structures consisting of [gamma] and [alpha][sub 2] or [beta] phases were obtained. The heat-treated alloys were tensile tested in vacuum and air at room temperature, and the environmental effect on tensile elongation was studied. The ductility of the alloys consisting of equiaxed [gamma] grains and a large amount of [alpha][sub 2] grains was not largely affecting by laboratory air, and a decrease in the amount of [alpha][sub 2] grains resulted in a large reduction of ductility in air. The [beta] phase in the Cr-containing alloy improved the ductility in vacuum, but it resulted in a large reduction of ductility in air.

  5. Innovative Systems for Solar Air Conditioning of Buildings 

    E-Print Network [OSTI]

    Kessling, W.; Peltzer, M.

    2004-01-01T23:59:59.000Z

    kessling@transsolar.com Dipl.-Ing. Matthias PELTZER Technical Director L-DCS Technology GmbH Muenchener Str. 101, 85737 Ismaning b. Munich matthias.peltzer@l-dcs.com ABSTRACT Solar air conditioning is an attractive technology to achieve comfortable room... states (4). The room return air (5) is used in a latent heat recovery (6) (psychometric process see Figure 4). To illuminate the excellent system performance a typical cooling load profile for a standard office build- ing in the hot and humid climate...

  6. Compressed Air Systems Audits - Why? And How?

    E-Print Network [OSTI]

    Kemp, H. L.

    2004-01-01T23:59:59.000Z

    . Secondly, join us in the definition of compressed air as a system, the totality of which is comprised of the Supply Side and the Demand Side. The Supply Side is the compressors and their controls, receivers (primary storage tanks), aftercoolers, filters... and dryers, and ends at the Compressor Room door. The Demand side is all of the distribution piping system, and all of the end uses of the compressed air, including leaks The function of the audit (be it walk-through, assessment or full audit...

  7. Air Pollution (Illinois)

    Broader source: Energy.gov [DOE]

    This article states regulations for monitoring air pollution, methods for permit applications, emission limitations for pollutants and air quality standards.

  8. Air exchange effectiveness of conventional and task ventilation for offices

    SciTech Connect (OSTI)

    Fisk, W.J.; Faulkner, D.; Prill, R.J.

    1991-12-01T23:59:59.000Z

    Air quality and comfort complaints within large buildings are often attributed to air distribution problems. We define three air exchange effectiveness parameters related to air distribution. The first two indicate the indoor air flow pattern (i.e., the extent of short circuiting, mixing, or displacement flow) for an entire building or region. The third parameter is most useful for assessments of the spatial variability of ventilation. We also define the air diffusion effectiveness which indicates the air flow pattern within specific rooms or sections of buildings. The results of measurements of these parameters in US office buildings by the authors and other researchers are reviewed. Almost all measurements indicate very limited short circuiting or displacement flow between locations of air supply and removal. However, a moderate degree of short circuiting is evident from a few measurements in rooms with heated supply air. The results of laboratory-based measurements by the authors are consistent with the field data. Our measurements in office buildings do indicate that ventilation rates can vary substantially between indoor locations, probably due to variation in air supply rates between locations rather than variation in the indoor air flow patterns. One possible method of improving air distribution is to employ task ventilation with air supplied closer to the occupant`s breathing zone. We have evaluated two task ventilation systems in a laboratory setting. During most operating conditions, these systems did not provide a region of substantially increased ventilation where occupants breath. However, both systems are capable of providing substantially enhanced ventilation at the breathing zone under some operating conditions. Therefore, task ventilation is a potential option for using ventilation air more effectively.

  9. Air exchange effectiveness of conventional and task ventilation for offices

    SciTech Connect (OSTI)

    Fisk, W.J.; Faulkner, D.; Prill, R.J.

    1991-12-01T23:59:59.000Z

    Air quality and comfort complaints within large buildings are often attributed to air distribution problems. We define three air exchange effectiveness parameters related to air distribution. The first two indicate the indoor air flow pattern (i.e., the extent of short circuiting, mixing, or displacement flow) for an entire building or region. The third parameter is most useful for assessments of the spatial variability of ventilation. We also define the air diffusion effectiveness which indicates the air flow pattern within specific rooms or sections of buildings. The results of measurements of these parameters in US office buildings by the authors and other researchers are reviewed. Almost all measurements indicate very limited short circuiting or displacement flow between locations of air supply and removal. However, a moderate degree of short circuiting is evident from a few measurements in rooms with heated supply air. The results of laboratory-based measurements by the authors are consistent with the field data. Our measurements in office buildings do indicate that ventilation rates can vary substantially between indoor locations, probably due to variation in air supply rates between locations rather than variation in the indoor air flow patterns. One possible method of improving air distribution is to employ task ventilation with air supplied closer to the occupant's breathing zone. We have evaluated two task ventilation systems in a laboratory setting. During most operating conditions, these systems did not provide a region of substantially increased ventilation where occupants breath. However, both systems are capable of providing substantially enhanced ventilation at the breathing zone under some operating conditions. Therefore, task ventilation is a potential option for using ventilation air more effectively.

  10. Application of the VRV Air-Conditioning System Heat Recovery Series in Interior Zone and Analysis of its Energy Saving

    E-Print Network [OSTI]

    Zhang, Q.; Li, D.; Zhang, J.

    2006-01-01T23:59:59.000Z

    To reduce the energy consumption of air conditioning systems, we can use the VRV air conditioning system to supply cold loads in the winter for rooms in the construction inner zone where cold loads need to be supplied. The VRV air...

  11. Essays on the household-level effects of house price growth

    E-Print Network [OSTI]

    Sitgraves, Claudia Ayanna

    2009-01-01T23:59:59.000Z

    replacement of major equipment items such as water heaters, furnaces, and central air conditioners” (

  12. California DREAMing: the design of residential demand responsive technology with people in mind

    E-Print Network [OSTI]

    Peffer, Therese E.

    2009-01-01T23:59:59.000Z

    replacement (Vandervort, 2006). The proper changing of the refrigerant can also significantly improve air conditioner

  13. Essays on the household-level effects of house price growth

    E-Print Network [OSTI]

    Sitgraves, Claudia Ayanna

    2009-01-01T23:59:59.000Z

    and replacement of major equipment items such as water heaters, furnaces, and central air conditioners” (

  14. A Generalized Battery Model of a Collection of Thermostatically Controlled Loads for Providing Ancillary Service

    E-Print Network [OSTI]

    Sanandaji, Borhan M.

    . Residential Thermostatically Controlled Loads (TCLs) such as air conditioner, heat pump, water heater, and re

  15. Investigation of efficiency droop for InGaN-based UV light-emitting diodes with InAlGaN barrier

    E-Print Network [OSTI]

    applications in photocatalytic deodorizing such as air conditioner,1 and there have been interests in solid

  16. IMPACT OF FOREST CERTIFICATION: FROM THE PERSPECTIVE OF FOREST CONCESSIONAIRES' STAFFS

    E-Print Network [OSTI]

    by acting as anti pollutants, natural air conditioner and balancing the ecosystem. However, deforestation

  17. ARRA Proposed Award: The Affordable Multifamily Retrofit Initiative (the Initiative)

    E-Print Network [OSTI]

    Star appliance replacement; air conditioner and/or furnace replacement or installation defect repair; cool roofs

  18. Applied Intelligence 13, 259264, 2000 c 2000 Kluwer Academic Publishers. Manufactured in The Netherlands.

    E-Print Network [OSTI]

    Covington, Michael A.

    Problem Consider the following rules for controlling an air conditioner: (1) Run the air conditioner when the temperature is over 78 . (2) Do not run the air conditioner when the AC line voltage is low, unless) Never run the air conditioner if it was turned off less than 4 minutes ago (to protect the compressor

  19. ARRA Proposed Award: Home Performance Program

    E-Print Network [OSTI]

    Star appliance replacement; air conditioner and/or furnace replacement or installation defect repair; cool roofs

  20. Volume 9 Number 3 Fall 2000 University to invest

    E-Print Network [OSTI]

    manager of Purdue's mechanical and electrical structures, had all the window air conditioner units removed

  1. SpecialBulletin page 1California Energ y Commission March 2006 no. 84

    E-Print Network [OSTI]

    that the federal air conditioner standards that require a minimum SEER 13 went into effect on January 23, 2006. Can an air conditioner that has a SEER rating less than SEER 13 be installed in newly constructed buildings of manufacture of the air conditioner. To comply with the federal appliance standards, any air conditioner

  2. TENANT NAME ADDRESS APT#

    E-Print Network [OSTI]

    Kravets, Robin

    cabinets Bath exhaust fan Medicine cabinet Air conditioner Washer/dryer Other # KEYS: RECEIVED RETURNED

  3. Additions, Alterations, and Repairs Introduction Page 8-1 8 Additions, Alterations, and Repairs

    E-Print Network [OSTI]

    conditioning and heating system. 5. Replacing an air conditioner or the exterior unit or indoor coil of a split system air conditioner. 6. Replacing of a furnace or water heater. 7. Replacing windows where all compressor in an air conditioner but not replacing the entire air conditioner. 3. Replacing a failed fan

  4. 2013 California Building Energy Efficiency Standards December 2011 CODES AND STANDARDS ENHANCEMENT INITIATIVE (CASE)

    E-Print Network [OSTI]

    ...................................................................................23 4.3.4 The Effect of Non-condensables on Air Conditioner Efficiency

  5. Innostock 2012 The 12th International Conference on Energy Storage

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    market is 9% between 1996 and 2000 and only 18% of sold air conditioner are replacements for existing air) T Temperature (°C) t Time (s) v Air velocity (m.s-1 ) x Axial coordinates (m) Y Internal tube width (m) Z conductivity (W.m-1 .K-1 ) Density (kg.m-3 ) Molten fraction (-) Subscripts a Air ext Experimental room fd

  6. Potential Impact of Adopting Maximum Technologies as Minimum Efficiency Performance Standards in the U.S. Residential Sector

    E-Print Network [OSTI]

    Letschert, Virginie

    2010-01-01T23:59:59.000Z

    air conditioners, water heaters and furnaces) are modeledair conditioners, water heaters and furnaces) UnregulatedBAT option for electric water heater and condensing water

  7. U< I 7 jjORNLCON-3S) EXPERIMENTAL ANALYSIS OF A WINDOW

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    UAIR CONDITIONER OAK RIDGE WITH NATIONAL R-22. #12;ORNUCON-389 EXPERIMENTAL ANALYSIS OF A WINDOW AIR CONDITIONER WITH R-22 AND ZEOTROPIC MIXTURE OF R

  8. A New Control Room for SLAC Accelerators

    SciTech Connect (OSTI)

    Erickson, Roger; Guerra, E.; Stanek, M.; Hoover, Z.Van; Warren, J.; /SLAC

    2012-06-04T23:59:59.000Z

    We are planning to construct a new control room at SLAC to unify and improve the operation of the LCLS, SPEAR3, and FACET accelerator facilities, and to provide the space and flexibility needed to support the LCLS-II and proposed new test beam facilities. The existing control rooms for the linac and SPEAR3 have been upgraded in various ways over the last decade, but their basic features have remained unchanged. We propose to build a larger modern Accelerator Control Room (ACR) in the new Research Support Building (RSB) which is currently under construction at SLAC. Shifting the center of control for the accelerator facilities entails both technical and administrative challenges. In this paper, we describe the history, concept, and status of this project.

  9. News Room | Princeton Plasma Physics Lab

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOnItemResearch > The EnergyCenterDioxideDocumentationThreeNews Releases NewsRoomRoom

  10. Metal-Air Batteries

    SciTech Connect (OSTI)

    Zhang, Jiguang; Bruce, Peter G.; Zhang, Gregory

    2011-08-01T23:59:59.000Z

    Metal-air batteries have much higher specific energies than most currently available primary and rechargeable batteries. Recent advances in electrode materials and electrolytes, as well as new designs on metal-air batteries, have attracted intensive effort in recent years, especially in the development of lithium-air batteries. The general principle in metal-air batteries will be reviewed in this chapter. The materials, preparation methods, and performances of metal-air batteries will be discussed. Two main metal-air batteries, Zn-air and Li-air batteries will be discussed in detail. Other type of metal-air batteries will also be described.

  11. AirUCI Summer 2006 Schedule Monday, June 26th

    E-Print Network [OSTI]

    Nizkorodov, Sergey

    ) Noon to 4 pm: Room RH 481 (and RH 350) · Lab safety issues · General tours of the analytical chemistry experiments: 1. HPLC of cigarette smoke 2. GC/MS of gasoline vapor 3. FTIR of ethanol content of vodka - Review of computational chemistry 12 pm to 1 pm: Lunch with AirUCI faculty and researchers (provided) 1

  12. AirUCI Summer 2007 Schedule Monday, June 25th

    E-Print Network [OSTI]

    Nizkorodov, Sergey

    smoke 2. GC/MS of gasoline vapor 3. FTIR of ethanol content of vodka and mouthwash 4. Ozone generation pm: Room RH 481 · General tours of the analytical chemistry labs and AirUCI shared labs · Common lab in analytical chemistry - Absorption of specific wavelengths by molecules; Beer's Law (p. 170­175, 185­187, 191

  13. (ENFORCEMENT AGENCY CAN CUSTOMIZE WITH LETTERHEAD/SEAL)

    E-Print Network [OSTI]

    have a minimum 78% AFUE (Exception: Wall & floor furnaces; room heaters). 2. Central air conditioners, but are not limited to: · New HVAC installation · HVAC Changeout · Replacement of furnace, coil, FAU, or condenser · Relocation of an existing HVAC unit · Adding or replacing more than 40ft ducting in unconditioned space 2008

  14. (ENFORCEMENT AGENCY CAN CUSTOMIZE WITH LETTERHEAD/SEAL

    E-Print Network [OSTI]

    have a minimum 78% AFUE (Exception: Wall & floor furnaces; room heaters). 2. Central air conditioners, but are not limited to: · New HVAC installation · HVAC Changeout · Replacement of furnace, coil, FAU, or condenser · Relocation of an existing HVAC unit · Adding or replacing more than 40ft ducting in unconditioned space 2008

  15. MC Appliance: Order (2012-CE-1508)

    Broader source: Energy.gov [DOE]

    DOE ordered CNA International Inc. d/b/a MC Appliance Corporation to pay a $8,000 civil penalty after finding MC Appliance had failed to certify that certain models of room air conditioners comply with the applicable energy conservation standards.

  16. GreenFS: Making Enterprise Computers Greener by Protecting Them Better

    E-Print Network [OSTI]

    Zadok, Erez

    the power consumption, noise, and data reliability problems without sacrificing hard disk life­time, dataFS improves enterprise data protection, minimizes disk drive­related power consumption and noise and increases and increase the power consumption of fans and air conditioners. In a densely packed server room heat removal

  17. GreenFS: Making Enterprise Computers Greener by Protecting Them Better

    E-Print Network [OSTI]

    Zadok, Erez

    the power consumption, noise, and data reliability problems without sacrificing hard disk life-time, dataFS improves enterprise data protection, minimizes disk drive-related power consumption and noise and increases and increase the power consumption of fans and air conditioners. In a densely packed server room heat removal

  18. Macquarie University Design Standards ROOM DATA SHEETS

    E-Print Network [OSTI]

    Wang, Yan

    ALARM Thermal Smoke POWER GPO's Dedicated GPO 3 phase Oven UPS AUDIOVISUAL OUTLETS Outlets Video projector Induction loop #12;Macquarie University Design Standards Section S ANNEXURE 9 ROOM DATA SHEETS) Conference chair Coffee table Blinds Modular table Microwave Oven Curtains Conference table Refrigerator

  19. Registrar's Office Room 130, 6299 South Street

    E-Print Network [OSTI]

    Brownstone, Rob

    Registrar's Office Room 130, 6299 South Street Henry Hicks Academic Administration Bldg PO Box, Visa, MasterCard, American Express or debit in person. Please do not send cash in the mail or enclose Integrated Science Program Skills Transcript (for courses completed between September 1998 and April 2005

  20. Einstein Room Reservations Rules and Regulations

    E-Print Network [OSTI]

    Yates, Andrew

    Einstein Room Reservations Rules and Regulations Before Reservation: Requests are not confirmed Activities, Joan Junger, (718) 430-2105 or student.activities@einstein.yu.edu. A meeting or conversation in accordance to Albert Einstein College of Medicine's Alcohol Policy. Before your request is confirmed you must