Powered by Deep Web Technologies
Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

RFC | OpenEI  

Open Energy Info (EERE)

RFC RFC Dataset Summary Description Datasets are for the US electricity grid system interconnect regions (ASCC, FRCC, HICC, MRO, NPCC, RFC, SERC, SPP, TRE, WECC) for 2008. The data is provided in life cycle inventory (LCI) forms (both xls and xml). A module report and a detailed spreadsheet are also included. Source US Life Cycle Inventory Database Date Released May 01st, 2011 (3 years ago) Date Updated Unknown Keywords ASCC FRCC HICC interconnect region LCI life cycle inventory MRO NPCC RFC SERC SPP TRE unit process US utilities WECC Data application/zip icon interconnect_lci_datasets_2008.zip (zip, 6.3 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL)

2

PJM Interconnection (Multiple States) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

PJM Interconnection (Multiple States) PJM Interconnection (Multiple States) PJM Interconnection (Multiple States) < Back Eligibility Developer Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Delaware Program Type Interconnection PJM (originally Pennsylvania, Jersey, Maryland) Interconnection is a Regional Transmission Organization (RTO) that coordinates the movement of wholesale electricity in all or parts of Delaware, Illinois, Indiana, Kentucky, Maryland, Michigan, New Jersey, North Carolina, Ohio, Pennsylvania, Tennessee, Virginia, West Virginia and the District of Columbia. The PJM region has an area of 214,000 square miles, a population of about 60 million and a peak demand of 163,848 megawatts

3

PJM Controller Testing with Prototypic PJM Nozzle Configuration  

SciTech Connect (OSTI)

The U.S. Department of Energy (DOE) Office of River Protections Waste Treatment Plant (WTP) is being designed and built to pre-treat and then vitrify a large portion of the wastes in Hanfords 177 underground waste storage tanks. The WTP consists of three primary facilitiespretreatment, low-activity waste (LAW) vitrification, and high-level waste (HLW) vitrification. The pretreatment facility will receive waste piped from the Hanford tank farms and separate it into a high-volume, low-activity liquid stream stripped of most solids and radionuclides and a much smaller volume of HLW slurry containing most of the solids and most of the radioactivity. Many of the vessels in the pretreatment facility will contain pulse jet mixers (PJM) that will provide some or all of the mixing in the vessels. Pulse jet mixer technology was selected for use in black cell regions of the WTP, where maintenance cannot be performed once hot testing and operations commence. The PJMs have no moving mechanical parts that require maintenance. The vessels with the most concentrated slurries will also be mixed with air spargers and/or steady jets in addition to the mixing provided by the PJMs. Pulse jet mixers are susceptible to overblows that can generate large hydrodynamic forces, forces that can damage mixing vessels or their internal parts. The probability of an overblow increases if a PJM does not fill completely. The purpose of the testing performed for this report was to determine how reliable and repeatable the primary and safety (or backup) PJM control systems are at detecting drive overblows (DOB) and charge vessel full (CVF) conditions. Testing was performed on the ABB 800xA and Triconex control systems. The controllers operated an array of four PJMs installed in an approximately 13 ft diameter 15 ft tall tank located in the high bay of the Pacific Northwest National Laboratory (PNNL) 336 Building test facility. The PJMs were fitted with 4 inch diameter discharge nozzles representative of the nozzles to be used in the WTP. This work supplemented earlier controller tests done on PJMs with 2 inch nozzles (Bontha et al. 2007). Those earlier tests enabled the selection of appropriate pressure transmitters with associated piping and resulted in an alternate overblow detection algorithm that uses data from pressure transmitters mounted in a water flush line on the PJM airlines. Much of that earlier work was only qualitative, however, due to a data logger equipment failure that occurred during the 2007 testing. The objectives of the current work focused on providing quantitative determinations of the ability of the BNI controllers to detect DOB and CVF conditions. On both control systems, a DOB or CVF is indicated when the values of particular internal functions, called confidence values, cross predetermined thresholds. There are two types of confidence values; one based on a transformation of jet pump pair (JPP) drive and suction pressures, the other based on the pressure in the flush line. In the present testing, we collected confidence levels output from the ABB and Triconex controllers. These data were analyzed in terms of the true and noise confidence peaks generated during multiple cycles of DOB and CVF events. The distributions of peak and noise amplitudes were compared to see if thresholds could be set that would enable the detection of DOB and CVF events at high probabilities, while keeping false detections to low probabilities. Supporting data were also collected on PJM operation, including data on PJM pressures and levels, to provide direct experimental evidence of when PJMs were filling, full, driving, or overblowing.

Bontha, Jagannadha R.; Nigl, Franz; Weier, Dennis R.; Leigh, Richard J.; Johnson, Eric D.; Wilcox, Wayne A.; Pfund, David M.; Baumann, Aaron W.; Wang, Yeefoo

2009-08-21T23:59:59.000Z

4

ATP Utilization by Yeast Replication Factor C III. THE ATP-BINDING DOMAINS OF Rfc2, Rfc3, AND Rfc4 ARE ESSENTIAL FOR DNA RECOGNITION AND  

E-Print Network [OSTI]

ATP Utilization by Yeast Replication Factor C III. THE ATP-BINDING DOMAINS OF Rfc2, Rfc3, AND Rfc4 lysine in the Walker A motif of the ATP- binding domain encoded by the yeast RFC1, RFC2, RFC3, and RFC4 loading activity. In addition to their defects in ATP hydrolysis, these complexes were defective for DNA

Burgers, Peter M.

5

Response from PJM Interconnection LLC and Pepco to Department...  

Broader source: Energy.gov (indexed) [DOE]

PJM Interconnection LLC and Pepco to Department of Energy Request for Information Concerning the Potential Need for Potomac River Station Generation Response from PJM...

6

Pepco and PJM Interconnection Comments on District of Columbia...  

Broader source: Energy.gov (indexed) [DOE]

Pepco and PJM Interconnection Comments on District of Columbia Public Service Commission, Docket No. EO-05-01 Comments and Answer to Requests for Rehearing Pepco and PJM...

7

PJM Interconnection Interview on Wind  

Wind Powering America (EERE)

Vol. 9, No. 5 - December 5, 2007 Vol. 9, No. 5 - December 5, 2007 PJM on wind Wind power is growing rapidly in the United States and in Pennsylvania where 8 wind farms that total 259 megawatts now operate. Those wind farms already generate enough power for about 80,000 homes. Another 4,714 megawatts are in various stages of development within Pennsylvania, which would create enough power for an additional 1.4 mil- lion homes. Just in the Keystone state, wind power is creating thousands of jobs. Across the nation, wind power provides hundreds of millions of dollars of tax payments and rental fees to land- owners, and displaces more and more electricity that would otherwise be made by burning coal, oil, or natural gas. Wind farms create zero air pollution; require no destructive

8

PJM Interconnection, LLC | Open Energy Information  

Open Energy Info (EERE)

PA References: SGIC1 This article is a stub. You can help OpenEI by expanding it. PJM Interconnection, LLC Smart Grid Project was awarded 13,698,091 Recovery Act Funding...

9

PJM Presentation- The Silver Bullet: Storage! (July 12, 2011)  

Broader source: Energy.gov [DOE]

Presentation by Terry Boston, President and CEO pf PJM Interconnection before the ElectricityAdvisorty Committee, July 12, 2011,on storage for the smart grid.

10

Pepco and PJM Interconnection Comments on District of Columbia Public  

Broader source: Energy.gov (indexed) [DOE]

Pepco and PJM Interconnection Comments on District of Columbia Pepco and PJM Interconnection Comments on District of Columbia Public Service Commission, Docket No. EO-05-01 Comments and Answer to Requests for Rehearing Pepco and PJM Interconnection Comments on District of Columbia Public Service Commission, Docket No. EO-05-01 Comments and Answer to Requests for Rehearing Docket No. EO-05-01: In accordance with Order No. 202-06-1, issued by the Department of Energy on February 17, 2006. Potomac Electric Power Company and PJM Interconnection, L.L.C. jointly submit these comments and answer to the requests for rehearing submitted by the City of Alexandria, Virginia and the Director of the Virginia Department of Environmental Quality in the captioned proceeding . Pepco and PJM Interconnection Comments on District of Columbia Public

11

Property:EIA/861/RtoPjm | Open Energy Information  

Open Energy Info (EERE)

RtoPjm RtoPjm Jump to: navigation, search Property Name RTO_PJM Property Type Boolean Description Indicates that the organization conducts operations in the PJM RTO [1] References ↑ "EIA Form EIA-861 Final Data File for 2010 - 861 Webfile Layout for 2010.doc" Pages using the property "EIA/861/RtoPjm" Showing 25 pages using this property. (previous 25) (next 25) A A & N Electric Coop (Virginia) + true + Adams Electric Cooperative Inc + true + Adams Rural Electric Coop, Inc + true + Allegheny Electric Coop Inc + true + Allegheny Energy Supply Co LLC + true + American Mun Power-Ohio, Inc + true + Appalachian Power Co + true + Atlantic City Electric Co + true + B Bedford Rural Elec Coop, Inc + true + Borough of Butler, New Jersey (Utility Company) + true +

12

Commercial Building Loads Providing Ancillary Services in PJM  

E-Print Network [OSTI]

Council of Texas market." Energy 35 (4): 1536-1543.in US electricity markets." Energy Policy 62: 1031-1039.regulation in PJMs markets. Energy Impacts: Frequency and

MacDonald, Jason

2014-01-01T23:59:59.000Z

13

Answer of Potomac Electric Power Company and PJM lnterconnection...  

Broader source: Energy.gov (indexed) [DOE]

Answer of Potomac Electric Power Company and PJM lnterconnection, L.L.C. to the October 6, 2005 motion filed by the Virginia Department of Environmental Quality Answer of Potomac...

14

Preliminary Response of PJM Interconnection, L.L.C. to the Operating...  

Broader source: Energy.gov (indexed) [DOE]

Response of PJM Interconnection, L.L.C. to the Operating Plan of Mirant Potomac River, LLC Preliminary Response of PJM Interconnection, L.L.C. to the Operating Plan of Mirant...

15

Response by PJM to letters from the City of Alexandria and the...  

Broader source: Energy.gov (indexed) [DOE]

by PJM to letters from the City of Alexandria and the Virginia Department of Environmental Quality pursuant to Order No. 202-05-03 Response by PJM to letters from the City of...

16

SPACE WEATHER AND THE INCIDENCE OF REACTIVE "OFF-COST" OPERATIONS IN THE PJM POWER GRID  

E-Print Network [OSTI]

SPACE WEATHER AND THE INCIDENCE OF REACTIVE "OFF-COST" OPERATIONS IN THE PJM POWER GRID 7.6 Kevin F the price of electricity in the PJM power grid. In this paper we examine one of the mechanisms by which space weather impacts the electricity market in the PJM power grid. The starting point of this paper

Schrijver, Karel

17

PJM's Capacity Market in a Price-Spike World Steven Stoft  

E-Print Network [OSTI]

PWP-077 PJM's Capacity Market in a Price-Spike World Steven Stoft May, 2000 This paper is part, California 94720-5180 www.ucei.org #12;PJM's Capacity Market in a Price-Spike World Steven Stoft 1 May 7, 2000 Abstract PJM's market was designed to rely on a capacity market instead of price-spikes to induce

California at Berkeley. University of

18

Property:EIA/861/NercRfc | Open Energy Information  

Open Energy Info (EERE)

NercRfc NercRfc Jump to: navigation, search This is a property of type Boolean. Description: Nerc Rfc Entity conducts business operations within the RFC region (Y or N) [1] References ↑ EIA Form EIA-861 Final Data File for 2008 - F861 File Layout-2008.doc Pages using the property "EIA/861/NercRfc" Showing 25 pages using this property. (previous 25) (next 25) A A & N Electric Coop (Virginia) + true + AEP Generating Company + true + AGC Division of APG Inc + true + Adams Electric Cooperative Inc + true + Adams Rural Electric Coop, Inc + true + Allegheny Electric Coop Inc + true + Allegheny Energy Supply Co LLC + true + Alpena Power Co + true + Ameren Energy Marketing + true + American Mun Power-Ohio, Inc + true + American Transmission Systems Inc + true +

19

PJM Interconnection, LLC Smart Grid Project | Open Energy Information  

Open Energy Info (EERE)

LLC Smart Grid Project LLC Smart Grid Project Jump to: navigation, search Project Lead PJM Interconnection, LLC Country United States Headquarters Location Norristown, Pennsylvania Additional Benefit Places Illinois, Indiana, Kentucky, Maryland, Michigan, North Carolina, New Jersey, Ohio, Pennsylvania, Virgin Islands, West Virginia Recovery Act Funding $13,698,091.00 Total Project Value $228203511 Coverage Area Coverage Map: PJM Interconnection, LLC Smart Grid Project Coordinates 40.121497°, -75.3399048° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

20

Motion to Intervene and Initial Comments of PJM Interconnection, L.L.C. |  

Broader source: Energy.gov (indexed) [DOE]

and Initial Comments of PJM Interconnection, and Initial Comments of PJM Interconnection, L.L.C. Motion to Intervene and Initial Comments of PJM Interconnection, L.L.C. Motion to Intervene and Initial Comments of PJM Interconnection, L.L.C. On January 5, 2009, ITC Transmission filed with the Department of Energy a request to amend Presidential Permit PP-230-3, which authorizes ITC to own and operate specified electric transmission facilities at the Bunce Creek station that interconnect ITC with Hydro One Networks Inc electric transmission facilities at the Michigan-Ontario border. Motion to Intervene and Initial Comments of PJM Interconnection, L.L.C. More Documents & Publications Application for presidential permit OE Docket No. PP-230-4 International Transmission Company: Response of PJM Interconnection, L.L.C. to Answer of

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Impacts of wind power on PJM market development  

Science Journals Connector (OSTI)

Recently, there has been a substantial growth in wind energy in the USA. An increasing number of states are experiencing market design, planning and investment in wind energy with this growth. Currently, wind installations exist in more than half of the states. This paper explores the market factors that have been driven and affected by large-scale wind energy development in the USA, particularly in PJM control area that have achieved in recent years and will have a substantial amount of wind energy investment in the next 10??15 years. In this paper, we also identify the key issues for wind power planning and interconnection.

Zhenyu Fan; Hui Ni

2008-01-01T23:59:59.000Z

22

RFC Sand Creek Development LLC | Open Energy Information  

Open Energy Info (EERE)

RFC Sand Creek Development LLC RFC Sand Creek Development LLC Jump to: navigation, search Name RFC Sand Creek Development LLC Place Aurora, Colorado Zip 80014 Product Subsidiary of Republic Financial Corporation set up to invest in Sand Creek Energy LLC, a planned gas to liquid facility. Coordinates 39.325162°, -79.54975° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":39.325162,"lon":-79.54975,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

23

Independent review of estimated load reductions for PJM's small customer load response pilot project  

E-Print Network [OSTI]

water heater (EWH) load control program operated as part of PJM Interconnections Demand ResponseDemand Response Economic and Emergency Load Response Programs Electric Thermal Storage Electric Water Heaterwater pumps and electric thermal storage space heaters. The CSP is also participating in PJMs pilot Demand Response

Heffner, G.; Moezzi, M.; Goldman, C.

2004-01-01T23:59:59.000Z

24

Answer of Potomac Electric Power Company and PJM lnterconnection, L.L.C. to  

Broader source: Energy.gov (indexed) [DOE]

Answer of Potomac Electric Power Company and PJM lnterconnection, Answer of Potomac Electric Power Company and PJM lnterconnection, L.L.C. to the October 6, 2005 motion filed by the Virginia Department of Environmental Quality Answer of Potomac Electric Power Company and PJM lnterconnection, L.L.C. to the October 6, 2005 motion filed by the Virginia Department of Environmental Quality Docket No. EO-05-01: Pursuant to Rule 213 of the rules of Practice and Procedure of the Federal Energy Regulatory Commission ("FERC" or "Commission"), 18 C.F.R. § 385.213, Potomac Electric Power Company ("Pepco") and PJM Interconnection, L.L.C. ("PJM") hereby answer the Motion of Robert G. Bumley, Director the Commonwealth of Virginia Department of Environmental Quality To Deny the District of Columbia Public Service

25

Response from PJM Interconnection LLC and Pepco to Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

PJM Interconnection LLC and Pepco to Department of PJM Interconnection LLC and Pepco to Department of Energy Request for Information Concerning the Potential Need for Potomac River Station Generation Response from PJM Interconnection LLC and Pepco to Department of Energy Request for Information Concerning the Potential Need for Potomac River Station Generation Docket No. EO-05-01: This letter will respond to your request for information concerning the potential need for Potomac River Station generation under the three reliability "scenarios" outlined by PJM and PEPCO. Response from PJM Interconnection LLC and Pepco to Department of Energy Request for Information Concerning the Potential Need for Potomac River Station Generation More Documents & Publications Information Concerning Reliability Impacts under Various System

26

Joint Maintenance Status Report of Potomac Electric Power Company amd PJM  

Broader source: Energy.gov (indexed) [DOE]

Joint Maintenance Status Report of Potomac Electric Power Company Joint Maintenance Status Report of Potomac Electric Power Company amd PJM Interconnection, LLC Joint Maintenance Status Report of Potomac Electric Power Company amd PJM Interconnection, LLC Docket No. EO-05-01: Potomac Electric Power Company ("Pepco") and PJM Interconnection, L.L.C. ("PJM") hereby jointly submit this Maintenance Report to advise you of the work completed and findings made during the maintenance outages for Pepco's two 230 kV circuits from the Palmers Comer to Potomac River substations pursuant to the December 20. 2006, Department of Energy ("DOE") Order No. 202-05-3. Joint Maintenance Status Report of Potomac Electric Power Company amd PJM Interconnection, LLC More Documents & Publications Special Environmental Analysis For Actions Taken under U.S. Department of

27

Response by PJM to letters from the City of Alexandria and the Virginia  

Broader source: Energy.gov (indexed) [DOE]

by PJM to letters from the City of Alexandria and the by PJM to letters from the City of Alexandria and the Virginia Department of Environmental Quality pursuant to Order No. 202-05-03 Response by PJM to letters from the City of Alexandria and the Virginia Department of Environmental Quality pursuant to Order No. 202-05-03 Docket No. EO-05-01: Following the release of the Department of Energy's Order No. 202-05-3 issued December 20, 2005 (the "Order"), both the Virginia Department of Environmental Quality ("DEQ") and the City of Alexandria (the "City") have filed letters asserting an imminent breach of the Order. PJM responds to those letters and takes issue both (i) with the assertion of an imminent breach of the Order, and (ii) the suggestion that maintenance of transmission facilities serving the District of Columbia be

28

Commercial Building Loads Providing Ancillary Services in PJM  

SciTech Connect (OSTI)

The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

MacDonald, Jason; Kiliccote, Sila; Boch, Jim; Chen, Jonathan; Nawy, Robert

2014-06-27T23:59:59.000Z

29

Assessment of the Performance of Fuzzy Cluster Analysis in the Classification of RFC Documents  

E-Print Network [OSTI]

on a relevance measure of other documents to the ones that are part of the defined tracks. The questionAssessment of the Performance of Fuzzy Cluster Analysis in the Classification of RFC Documents M. E of finding knowledge from meta-data. A collection of RFC documents has been used to analyse the behaviour

Haddadi, Hamed

30

DNA structure(s) recognized and bound by large subunit of Replication Factor C (ls RFC) in Drosophila melanogaster  

E-Print Network [OSTI]

of lsRFC protein purified from the maltose affinity column with protein in the crude extract . . 22 8. DNA sequence of synthetic oligonucleotides used to determine the binding affinity of Drosophila lsRFC protein . . 24 9. Relative binding affinity.... . . . . . . . . . . 15. The cutting pattern of "D" series of DNA structures by piperidine 33 after Os04/pyridine modification 34 16. Southwestern assay comparing relative binding affinity of MBP-IsRFC purified protein to DNA structures of "Y" series and "D" series...

Gaur, Lalit Kumar

1995-01-01T23:59:59.000Z

31

Independent review of estimated load reductions for PJM's small customer load response pilot project  

SciTech Connect (OSTI)

This study describes the results of a low-cost approach used to measure reported load reductions from a residential electric water heater (EWH) load control program operated as part of PJM Interconnection's Demand Response small customer pilot program. Lawrence Berkeley National Laboratory (LBNL) conducted this independent review of the engineering estimates for EWH load control reported by a Curtailment Service Provider (CSP) at PJM's request. LBNL employed low-cost measurement and verification (M&V) approaches that utilized existing interval metering equipment to monitor results for a series of load control tests. The CSP collected hourly load data for two substations and several hundred households over a six-week period in October and November 2003. During this time period, the CSP operated its electric water heater load control program during pre-specified test periods in the morning, afternoon and early evening. LBNL then analyzed substation and premise-level data from these tests in order to verify the diversified demand reductions claimed by the CSP for customers participating in the EWH load control program. We found that the observed load reductions for the premise-level data aggregated over all households in the two participating electric cooperatives were, respectively, 40 percent-60 percent less and 3 percent less-10 percent higher than the estimated diversified demand reduction values assumed by the CSP, depending on whether observed or normalized results are considered. We also analyzed sub-station level data and found that the observed load reductions during the test periods were significantly lower than expected, although confounding influences and operational problems signifiogram during pre-specified test periods in the morning, afternoon and early evening. LBNL then analyzed substation and premise-level data from these tests in order to verify the diversified demand reductions claimed by the CSP for customers participating in the EWH load control program. We found that the observed load reductions for the premise-level data aggregated over all households in the two participating electric cooperatives were, respectively, 40 percent-60 percent less and 3 percent less-10 percent higher than the estimated diversified demand reduction values assumed by the CSP, depending on whether observed or normalized results are considered. We also analyzed sub-station level data and found that the observed load reductions during the test periods were significantly lower than expected, although confounding influences and operational problems significantly limit our ability to differentiate between control-related and non-control related differences in substation-level load shape data. The usefulness and accuracy of the results were hampered by operational problems encountered during the measurement period as well as in sufficient number of load research grade interval meters at one cooperative. Given the larger sample size at one electric cooperative and more statistically-robust results, there is some basis to suggest that the Adjusted Diversified Demand Factor (ADDF) values used by the CSP somewhat over-state the actual load reductions. Given the results and limitations of the M&V approach as implemented, we suggest several options for PJM to consider: (1) require load aggregators participating in ISODR programs to utilize formal PURPA-compliant load research samples in their M&V plans, and (2) continue developing lower cost M&V approaches for mass market load control programs that incorporate suggested improvements described in this study.

Heffner, G.; Moezzi, M.; Goldman, C.

2004-06-01T23:59:59.000Z

32

Deemed Savings Estimates for Legacy Air Conditioning and WaterHeating Direct Load Control Programs in PJM Region  

SciTech Connect (OSTI)

During 2005 and 2006, the PJM Interconnection (PJM) Load Analysis Subcommittee (LAS) examined ways to reduce the costs and improve the effectiveness of its existing measurement and verification (M&V) protocols for Direct Load Control (DLC) programs. The current M&V protocol requires that a PURPA-compliant Load Research study be conducted every five years for each Load-Serving Entity (LSE). The current M&V protocol is expensive to implement and administer particularly for mature load control programs, some of which are marginally cost-effective. There was growing evidence that some LSEs were mothballing or dropping their DLC programs in lieu of incurring the expense associated with the M&V. This project had several objectives: (1) examine the potential for developing deemed savings estimates acceptable to PJM for legacy air conditioning and water heating DLC programs, and (2) explore the development of a collaborative, regional, consensus-based approach for conducting monitoring and verification of load reductions for emerging load management technologies for customers that do not have interval metering capability.

Goldman, Charles

2007-03-01T23:59:59.000Z

33

Allegheny Electric Coop Inc | Open Energy Information  

Open Energy Info (EERE)

332 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying...

34

City of Vineland, New Jersey (Utility Company) | Open Energy...  

Open Energy Info (EERE)

Utility Id 19856 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes...

35

Allegheny Energy Supply Co LLC | Open Energy Information  

Open Energy Info (EERE)

RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Wholesale Marketing Yes Activity Retail Marketing Yes This article is a stub. You can help...

36

The Energy Coop | Open Energy Information  

Open Energy Info (EERE)

Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Retail Marketing Yes This article is a stub. You can help OpenEI by expanding it. Utility...

37

Borough of Goldsboro, Pennsylvania (Utility Company) | Open Energy...  

Open Energy Info (EERE)

Data Utility Id 7359 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes This article is a stub. You can help OpenEI by expanding...

38

Mid-Ohio Energy Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Utility Id 36189 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes This article is a stub. You can help OpenEI by expanding...

39

Warren Electric Coop Inc | Open Energy Information  

Open Energy Info (EERE)

3 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes This article is a stub. You can help OpenEI by expanding it. Utility Rate...

40

Adams Rural Electric Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Data Utility Id 118 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes This article is a stub. You can help OpenEI by expanding...

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Village of Sycamore, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Utility Id 18393 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes This article is a stub. You can help OpenEI by expanding...

42

Pioneer Rural Elec Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Utility Id 15054 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes This article is a stub. You can help OpenEI by expanding...

43

New Enterprise R E C, Inc | Open Energy Information  

Open Energy Info (EERE)

Utility Id 13205 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes This article is a stub. You can help OpenEI by expanding...

44

Village of Plymouth, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Buying Transmission Yes Activity Distribution Yes This article is a stub. You can help OpenEI by...

45

AC Transit  

Broader source: Energy.gov [DOE]

AC Transit (or the Alameda-Contra Costa Transit District) is based in Oakland, California, and provides transportation services to the East Bay of San Francisco. The 360-square-mile service area includes 13 cities and adjacent unincorporated areas in Alameda and Contra Costa counties. AC Transit's approximately 638 vehicles serve more than 65 million annual passengers.

46

Washington Gas Energy Services | Open Energy Information  

Open Energy Info (EERE)

Utility Id 20659 Utility Location Yes Ownership R NERC RFC Yes RTO PJM Yes Activity Retail Marketing Yes This article is a stub. You can help OpenEI by expanding it. Utility...

47

Champion Energy Services | Open Energy Information  

Open Energy Info (EERE)

Id 54862 Utility Location Yes Ownership R NERC ERCOT Yes NERC RFC Yes ISO Ercot Yes RTO PJM Yes ISO MISO Yes Activity Retail Marketing Yes This article is a stub. You can help...

48

Accommodation & ACS Advertising Policy  

E-Print Network [OSTI]

Accommodation & Campus Services. ACS Advertising Policy This paper states the University department Accommodation & Campus Services' (ACS) policy on advertising, sponsorship and promotions and any restrictions. Accommodation & Campus Services, the Students' Union, all affiliated bodies and advertisers are expected

Stevenson, Mark

49

ACS-GDCh ALLIANCE  

Science Journals Connector (OSTI)

ACS-GDCh ALLIANCE ... Other aspects of the strategic collaboration alliance will identify additional activities and services that could be mutually beneficial to both ACS and GDCh members, in keeping with both organizations strategic goals. ...

MADELEINE JACOBS

2010-09-20T23:59:59.000Z

50

Celebrate Earth Day with ACS  

Science Journals Connector (OSTI)

Celebrate Earth Day with ACS ... Winners of the ACS-sponsored Earth Day 2004 music video contest are reported. ... ACS resources for celebrating the Earth Day 2005 theme, "AirHere, There, Everywhere", are discussed. ...

Erica K. Jacobsen

2005-03-01T23:59:59.000Z

51

Microfabricated AC impedance sensor  

DOE Patents [OSTI]

A microfabricated instrument for detecting and identifying cells and other particles based on alternating current (AC) impedance measurements. The microfabricated AC impedance sensor includes two critical elements: 1) a microfluidic chip, preferably of glass substrates, having at least one microchannel therein and with electrodes patterned on both substrates, and 2) electrical circuits that connect to the electrodes on the microfluidic chip and detect signals associated with particles traveling down the microchannels. These circuits enable multiple AC impedance measurements of individual particles at high throughput rates with sufficient resolution to identify different particle and cell types as appropriate for environmental detection and clinical diagnostic applications.

Krulevitch, Peter (Pleasanton, CA); Ackler, Harold D. (Sunnyvale, CA); Becker, Frederick (Houston, TX); Boser, Bernhard E. (Berkeley, CA); Eldredge, Adam B. (Austin, TX); Fuller, Christopher K. (Livermore, CA); Gascoyne, Peter R. C. (Bellaire, TX); Hamilton, Julie K. (Tracy, CA); Swierkowski, Stefan P. (Livermore, CA); Wang, Xiao-Bo (San Diego, CA)

2002-01-01T23:59:59.000Z

52

CD54AC04, CD74AC04 HEX INVERTERS  

E-Print Network [OSTI]

°C to 125°C SOIC M Tube CD74AC04M AC04M­55°C to 125°C SOIC ­ M Tape and reel CD74AC04M96 AC04M CDIP-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance

Kretchmar, R. Matthew

53

ACS | Open Energy Information  

Open Energy Info (EERE)

ACS ACS Jump to: navigation, search Name ACS Place Madrid, Spain Zip 28036 Sector Solar Product Madrid based construction company involved in the development of solar thermal projects. Coordinates 40.4203°, -3.705774° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.4203,"lon":-3.705774,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

54

AC | OpenEI  

Open Energy Info (EERE)

AC AC Dataset Summary Description The following data-set is for a benchmark residential home for all TMY3 locations across all utilities in the US. The data is indexed by utility service provider which is described by its "unique" EIA ID ( Source National Renewable Energy Laboratory Date Released April 05th, 2012 (2 years ago) Date Updated April 06th, 2012 (2 years ago) Keywords AC apartment CFL coffeemaker Computer cooling cost demand Dishwasher Dryer Furnace gas HVAC Incandescent Laptop load Microwave model NREL Residential television tmy3 URDB Data text/csv icon Residential Cost Data for Common Household Items (csv, 14.5 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL)

55

ETA-AC002  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2 2 Revision 2 Effective March 1, 1997 "Control of Test Conduct" Prepared by Electric Transportation Applications Prepared by: _______________________________ Date:__________ Jude M. Clark Approved by: _________________________________________________ Date: _______________ Donald B. Karner Procedure ETA-AC002 Revision 2 2 ©1997 Electric Transportation Applications All Rights Reserved TABLE OF CONTENTS 1.0 Objectives 3 2.0 Purpose 3 3.0 Documentation 3 4.0 Initial Conditions and Prerequisites 4 5.0 Personnel Qualifications 5 6.0 Activity Requirements 6 7.0 Supplemental Activity Requirements 8 8.0 Glossary 9 9.0 References 10 Procedure ETA-AC002 Revision 2 3 ©1997

56

ETA-AC006  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

6 6 Revision 2 Effective: March 1, 1997 Vehicle Verification Prepared by Electric Transportation Applications Prepared by: _______________________________ Date:__________ Jude M. Clark Approved by: _________________________________________________ Date: ______________ Donald B. Karner ETA-AC006 Revision 2 2 ©1997 Electric Transportation Applications All Rights Reserved TABLE OF CONTENTS 1.0 Objectives 3 2.0 Purpose 3 3.0 Documentation 3 4.0 Initial Conditions and Prerequisites 4 5.0 Verification Requirements 5 6.0 Glossary 11 7.0 References 12 Appendices Appendix A - Manufacturer's Proposal Review Check List 13 Appendix B - Vehicle Receipt Check List 18 ETA-AC006 Revision 2 3

57

Alternative Fuels at AC Transit  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Alternative Fuels at AC Transit Alternative Fuels at AC Transit Speaker(s): Jaimie Levin Date: November 1, 2011 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Eve Edelson Mr. Levin will discuss AC Transit's range of environmental technology initiatives, including: zero emission fuel cell transit buses; state-of-the-art, high-capacity, hydrogen fueling stations; solar energy systems; and stationary solid oxide fuel cell power generators. AC Transit has the largest fleet of fuel cell buses in the United States, featuring fuel cell systems with more than 10,000 hours of continuous operation without any failures or power degradation. Their fuel cell fleet has logged more than 400,000 miles of service and carried in excess of one million passengers. Come hear what AC Transit has learned, where they're headed,

58

AC resistance measuring instrument  

DOE Patents [OSTI]

An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.

Hof, P.J.

1983-10-04T23:59:59.000Z

59

Digital ac monitor  

DOE Patents [OSTI]

An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer. 24 figs.

Hart, G.W.; Kern, E.C. Jr.

1987-06-09T23:59:59.000Z

60

ACS calibration pipeline testing: error propagation  

E-Print Network [OSTI]

1 ACS calibration pipeline testing: error propagation Doug Van Orsow, Max Mutchler, Warren Hack files (see ISRs 99-03 "CALACS Operation and Implementation" by Hack and 99-04 "ACS calibra- tion

Sirianni, Marco

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

ACS SYMPOSIUM SERIES 966 Rational Environmental  

E-Print Network [OSTI]

ACS SYMPOSIUM SERIES 966 Rational Environmental Management of Agrochemicals Risk Assessment-Bayo, Editor Chiha University Sponsored by the ACS Division of Agrochemicals American Chemical Society of agrochemicals : risk assessment, monitoring, and remedial action / Ivan R. Kennedy, editor. ..[et al

Hammock, Bruce D.

62

ACS_RRA_2001.PDF  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Qualitative and Semi-quantitative Qualitative and Semi-quantitative Analysis Of Semi-volatile Organics from Ambient Air Fine-particulate Matter, PM 2.5 Richard Anderson, Don Martello, Brian R. Strazisar and Curt M. White richard.anderson@netl.doe.gov ACS-222 / RRA' / ST-10 / 8-28-2001 Different Missions * EPA - Protect the public health * DOE - Assist the private sector in supplying clean, abundant, and affordable energy ACS-222 / RRA' / ST-10 / 8-28-2001 PM 2.5 Regulatory Process * 1997 National Ambient Air Quality Standards (NAAQS) for PM 2.5 based on "health effects" - Mean annual concentration < 15 µg/m 3 - Maximum concentration < 65µg/ m 3 ACS-222 / RRA' / ST-10 / 8-28-2001 Why Is DOE Concerned About PM 2.5 ? * Coal-based power systems contribute to PM 2.5 - Primary particles * Ultra-fine fly-ash (Spherical Alumino-silicates,SAS), carbon soot

63

CD54AC08, CD74AC08 QUADRUPLE 2-INPUT POSITIVE-AND GATES  

E-Print Network [OSTI]

SOIC M Tube CD74AC08M AC08M­55°C to 125°C SOIC ­ M Tape and reel CD74AC08M96 AC08M CDIP ­ F Tube CD54AC-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance

Kretchmar, R. Matthew

64

M2ACS | M2ACS Web Space  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Welcome to the Multifaceted Mathematics for Complex Energy Systems (M2ACS) Welcome to the Multifaceted Mathematics for Complex Energy Systems (M2ACS) project webspace We are a multi-institution project whose aim is to fully explore the opportunities in applied mathematics brought about by multi-disciplinary focus - involving optimization, dynamical systems, stochastic analysis, discrete mathematics, scalable algorithms - on the DOE Grand Challenge of energy systems. The central research concept is the one of multi-faceted mathematics - whereby new mathematics is discovered by sustained investigation of the multiple facets presented by the grand challenge subproblems, such as nonconvexity, stochasticity, integrality, spatio-temporal variability - from the perspective of all the mathematics discipline area involved. Our project involves 22 principal investigators from 3 national

65

CD54AC02, CD74AC02 QUADRUPLE 2-INPUT POSITIVE-NOR GATES  

E-Print Network [OSTI]

to 125°C SOIC ­ M Tape and reel CD74AC02M96 AC02M CDIP ­ F Tube CD54AC02F3A CD54AC02F3A Package drawings-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance

Kretchmar, R. Matthew

66

CD54AC32, CD74AC32 QUADRUPLE 2-INPUT POSITIVE-OR GATES  

E-Print Network [OSTI]

Tape and reel CD74AC32M96 AC32M CDIP ­ F Tube CD54AC32F3A CD54AC32F3A Package drawings, standard-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance

Kretchmar, R. Matthew

67

AC corrosion on cathodically protected steel.  

E-Print Network [OSTI]

?? This report deals with the effect of alternating current on cathodically protected steel. AC corrosion has become relevant in the offshore industry due to (more)

Torstensen, Andreas

2012-01-01T23:59:59.000Z

68

Design of AC substation grounding system.  

E-Print Network [OSTI]

??The purpose for this paper is to understand the basic foundation used to safely design a substation grounding system for AC systems. The following criteria (more)

Meas, Ra

2014-01-01T23:59:59.000Z

69

Alameda-Contra Costa Transit District (AC Transit) Fuel Cell...  

Energy Savers [EERE]

(AC Transit) Fuel Cell Transit Buses: Preliminary Evaluation Results Alameda-Contra Costa Transit District (AC Transit) Fuel Cell Transit Buses: Preliminary Evaluation Results This...

70

AVTA: Blink AC Level 2 Charging System Testing Results | Department...  

Broader source: Energy.gov (indexed) [DOE]

Blink AC Level 2 Charging System Testing Results AVTA: Blink AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced Vehicle Testing Activity carries...

71

AVTA: Schneider AC Level 2 Charging System Testing Results |...  

Broader source: Energy.gov (indexed) [DOE]

Schneider AC Level 2 Charging System Testing Results AVTA: Schneider AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced Vehicle Testing Activity...

72

AVTA: Aerovironment AC Level 2 Charging System Testing Results...  

Broader source: Energy.gov (indexed) [DOE]

Aerovironment AC Level 2 Charging System Testing Results AVTA: Aerovironment AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced Vehicle Testing...

73

AVTA: SPX AC Level 2 Charging System Testing Results | Department...  

Broader source: Energy.gov (indexed) [DOE]

AVTA: SPX AC Level 2 Charging System Testing Results AVTA: SPX AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced Vehicle Testing Activity...

74

ACS Meeting and Chemical Exposition Draw Large Attendance  

Science Journals Connector (OSTI)

ACS Meeting and Chemical Exposition Draw Large Attendance ... Copyright 1958 American Chemical Society ...

1958-06-01T23:59:59.000Z

75

AC Ward Leonard drive systems: Revisiting the four-quadrant operation of AC machines  

Science Journals Connector (OSTI)

Abstract In this paper, the problem of controlling the speed of AC machines in four quadrants is revisited from a completely new viewpoint, based on the idea of powering an AC machine with a synchronous generator that generates a variable-voltagevariable-frequency supply. This is a natural, mathematical, but not physical, extension of the conventional Ward Leonard drive systems for DC machines to AC machines. As a result, AC drives can be regarded as generator-motor systems, which facilitate the analysis of AC drives and the introduction of other special functions because a system consisting of a generator and a motor is easier to be handled than the conventional AC drive that consists of an inverter and a motor. Control strategies, with and without a speed sensor, are proposed to implement this idea and the experimental results are presented to demonstrate the feasibility.

Qing-Chang Zhong

2013-01-01T23:59:59.000Z

76

Safe-commutation principle for direct single-phase AC-AC converters for use in audio power  

E-Print Network [OSTI]

Safe-commutation principle for direct single-phase AC-AC converters for use in audio power-stage AC-AC audio power amplifiers. As compared with the bridge commutation with load current or source is certainly the audio power amplification. Switching-mode Class D audio power amplifiers are becoming

77

Characterization of the rfc region of Shigella flexneri.  

Science Journals Connector (OSTI)

...position of migration of SR-LPS; R, position of migration of R-LPS. plot files generated by PROSIS into AUTOCAD (Autodesk Inc.). Nucleotide sequence accession number. The DNA sequence used in this study is available under GenBank and EMBL accession...

R Morona; M Mavris; A Fallarino; P A Manning

1994-02-01T23:59:59.000Z

78

BBF RFC 21: BglBricks Assembly Standard  

E-Print Network [OSTI]

The BglBricks standard has been developed as an alternative to the original XbaI/SpeI standard primarily to provide a solution to the issue of generating translational-fusion parts. When joined together in a standard ...

Anderson, J Christopher

2009-09-18T23:59:59.000Z

79

Antragsbeispiele API bzw. RfC (CR/C)/ITU  

Science Journals Connector (OSTI)

Nachfolgend findet sich ein Beispiel einer Advance Publication fr ein Satellitensystem mit niedrigfliegendem Satelliten (Rund-um-die-Welt-in-100-min) sprich eine sogenannte full API, die fr NGSO-Satellite...

Ren Wrfel; Hans Dodel

2012-01-01T23:59:59.000Z

80

ACS calibration pipeline testing: basic image reduction  

E-Print Network [OSTI]

Hack, Colin Cox Space Telescope Science Institute 28 May 1999 ABSTRACT This report describes the basic. For a detailed description of CALACS, see ACS Instrument Science Report 99-03 by Hack. This report describes

Sirianni, Marco

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

ACS workshop in India proposes eight projects  

Science Journals Connector (OSTI)

ACS workshop in India proposes eight projects ... Investigate the solid-state chemistry of processes and materials needed for using solar energy to split water and for transporting and storing the resulting hydrogen for use as a fuel. ...

1980-03-31T23:59:59.000Z

82

Three phase AC motor controller  

DOE Patents [OSTI]

A motor controller for a three phase AC motor (10) which is adapted to operate bidirectionally from signals received either from a computer (30) or a manual control (32). The controller is comprised of digital logic circuit means which implement a forward and reverse command signal channel (27, 29) for the application of power through the forward and reverse power switching relays (16, 18, 20, 22). The digital logic elements are cross coupled to prevent activation of both channels simultaneously and each includes a plugging circuit (65, 67) for stopping the motor upon the removal of control signal applied to one of the two channels (27, 29) for a direction of rotation desired. Each plugging circuit (65, 67) includes a one-shot pulse signal generator (88, 102) which outputs a single pulse signal of predetermined pulsewidth which is adapted to inhibit further operation of the application of power in the channel which is being activated and to apply a reversal command signal to the other channel which provides a reversed phase application of power to the motor for a period defined by the pulse-width output of the one-shot signal generator to plug the motor (10) which will then be inoperative until another rotational command signal is applied to either of the two channels.

Vuckovich, Michael (Elizabeth, PA); Wright, Maynard K. (Bethel Park, PA); Burkett, John P. (South Huntington Township, Westmoreland County, PA)

1984-03-20T23:59:59.000Z

83

r XXXX American Chemical Society A dx.doi.org/10.1021/ac201626b |Anal. Chem. XXXX, XXX, 000000 pubs.acs.org/ac  

E-Print Network [OSTI]

proposed as a platform for miniaturized chemical sen- sor systems. However, only a few systems achieve massr XXXX American Chemical Society A dx.doi.org/10.1021/ac201626b |Anal. Chem. XXXX, XXX, 000­000 ARTICLE pubs.acs.org/ac Chemical Vapor Detection Using a Capacitive Micromachined Ultrasonic Transducer

Khuri-Yakub, Butrus T. "Pierre"

84

EP-MAC e-mail : jyoak@snu.ac.kr, sbahk@snu.ac.kr  

E-Print Network [OSTI]

EP-MAC *, e-mail : jyoak@snu.ac.kr, sbahk@snu.ac.kr Early Preamble MAC to reduce-cycled wireless sensor motes. In this paper we propose Early Preamble-MAC(EP-MAC) which enables to get enhanced performance of low energy and low latency. EP-MAC uses both early preamble and original simple preamble, so

Bahk, Saewoong

85

debussy@cs.yonsei.ac.kr, iklee@yonsei.ac.kr Affective Icons for Music Exploring  

E-Print Network [OSTI]

O debussy@cs.yonsei.ac.kr, iklee@yonsei.ac.kr Affective Icons for Music Exploring Min and colors of harmonograph curves. These curves can be used as icons for music retrieval, and we demonstrate. This approach is compatible with a standard icon-based file browser. . Introduction Since the appearance

Lee, In-Kwon

86

schedule6_2005.xls  

U.S. Energy Information Administration (EIA) Indexed Site

Island Arsenal 6.4 UG 0 0 0 0 0 0 0 0 DLCO I 100 U RFC 0 AC 345 345 1195 512008 JK Smith Spurlock Avon 17.5 OH H S 954 ACSR 2 2 2 0 EKPC C 100 U RFC 0 AC 345 345 1195 51...

87

7AC Technologies, Inc. | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

7AC 7AC Technologies, Inc. America's Next Top Energy Innovator Challenge 498 likes 7AC Technologies, Inc. National Renewable Energy Laboratory Air conditioning is a very large contributor to U.S. and world energy consumption. Heating and cooling costs for commercial and industrial buildings exceed 25 percent of U.S. primary energy consumption (cooling alone accounts for 4.5 Quads out of 40 Quads) and typically accounts for almost half of a building's operating costs. Air conditioning is also a significant cause of grid instability with cycling compressor motors turning on and off, and causing load issues on hot summer days. Conventional air conditioners improve efficiency only marginally every year and retrofitting older rooftop units does not result in significant energy

88

7AC Technologies, Inc. | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

7AC 7AC Technologies, Inc. America's Next Top Energy Innovator Challenge 498 likes 7AC Technologies, Inc. National Renewable Energy Laboratory Air conditioning is a very large contributor to U.S. and world energy consumption. Heating and cooling costs for commercial and industrial buildings exceed 25 percent of U.S. primary energy consumption (cooling alone accounts for 4.5 Quads out of 40 Quads) and typically accounts for almost half of a building's operating costs. Air conditioning is also a significant cause of grid instability with cycling compressor motors turning on and off, and causing load issues on hot summer days. Conventional air conditioners improve efficiency only marginally every year and retrofitting older rooftop units does not result in significant energy

89

Princeton Plasma Physics Lab - AC power  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

ac-power The electricity that runs the ac-power The electricity that runs the Laboratory's experiments and facilities. "AC" stands for the alternating current that comes from large power stations. The term compares with "DC," for "direct current," which comes from sources like batteries. en Offshore Wind and Vehicle to Grid Power http://www.pppl.gov/events/offshore-wind-and-vehicle-grid-power

Professor Willett Kempton, of the University of Delaware, presents "Offshore Wind and Vehicle to Grid Power" as part of the Andlinger Center's 2013-2014 Highlight Seminar Series.

90

7AC Technologies, Inc. | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

7AC 7AC Technologies, Inc. America's Next Top Energy Innovator Challenge 498 likes 7AC Technologies, Inc. National Renewable Energy Laboratory Air conditioning is a very large contributor to U.S. and world energy consumption. Heating and cooling costs for commercial and industrial buildings exceed 25 percent of U.S. primary energy consumption (cooling alone accounts for 4.5 Quads out of 40 Quads) and typically accounts for almost half of a building's operating costs. Air conditioning is also a significant cause of grid instability with cycling compressor motors turning on and off, and causing load issues on hot summer days. Conventional air conditioners improve efficiency only marginally every year and retrofitting older rooftop units does not result in significant energy

91

www.mmu.ac.uk/careers Careers & Employability Service  

E-Print Network [OSTI]

.mmu.ac.uk/careers Identifying courses · www.prospects.ac.uk/search_courses.htm · www.jobs.ac.uk · www.Findamasters.com · www.mmu.ac.uk/careers PG Professional/Vocational courses: Courses to allow you to enter certain professions Courses involve lectures for the first two terms then a research project for the final term (often finishing after

92

AC H I E V I NG  

Broader source: Energy.gov (indexed) [DOE]

AC AC H I E V I NG The Department's strategic plan flow is highlighted in the cascade below beginning with the mission statement which flows to the strategic themes. The strategic themes connect to the broader strategic goals and are linked to the annual performance goals in the performance budget through the multi-year program plans. The multi-year program plans allow DOE to strategize over a five-year period how each program will implement the strategic goals of the Department. Annual performance goals and assessment of performance against prior-year

93

EXPERIMENTAL STUDY OF ELECTROLYTE DEPENDENCE OF AC ELECTROOSMOTIC PUMPS  

E-Print Network [OSTI]

EXPERIMENTAL STUDY OF ELECTROLYTE DEPENDENCE OF AC ELECTROOSMOTIC PUMPS Kapil Subramanian1 , John Abstract: Recent studies indicate increased efficiency of microfluidic ac electro-osmotic pumps of ac electroosmosis in microchannels on solution chemistry for the new fast aceo stepped pumps

Bazant, Martin Z.

94

Analysis and design of a direct AC to AC matrix converter topology  

E-Print Network [OSTI]

However, the NCC has the following disadvantages, 1. very limited(fow) output frequency range 2. subharmonics are generated at input and output side 3. poor input power factor These disadvantages can be overcome by employing forced commutated bidirec... diode sre connected anti-series. The main objectives of this thesis are summarized as follows, 1. Study and analysis of direct ac to ac matrix power converters. 2. Preseiitation of a new PWM control strategy to selectively eliminate unwanted lower...

Choi, Sewan

2012-06-07T23:59:59.000Z

95

www.jubileecentre.ac.uk JAMES ARTHUR  

E-Print Network [OSTI]

www.jubileecentre.ac.uk JAMES ARTHUR KRISTJÁN KRISTJÁNSSON HYWEL THOMAS MICHAEL HOLDSWORTH LUCA BADINI CONFALONIERI TIAN QIU FOREWORD BY PROFESSOR ADRIAN EVANS VIRTUOUS CHARACTERFOR THE PRACTICE OF LAW by Professor James Arthur. Based at the University of Birmingham, it has a dedicated team of 30 academics from

Birmingham, University of

96

AN "AC INDUCTOR" BASED GRID CONNECTED INVERTER  

E-Print Network [OSTI]

AN "AC INDUCTOR" BASED GRID CONNECTED INVERTER Ilya Zeltser, Student Member, IEEE and Sam Ben proposes a soft switched Output Current Sourcing (OCS) grid connected inverter that applies a high sourcing inverters where the small disturbance at the line voltage may lead to current run away

97

ACS Installation During SM3B Introduction  

E-Print Network [OSTI]

ACS Installation During SM3B Introduction: · Installed during SM3B in March 2002 · Powerful 3rd · Over-voltage Protection kit installed · Optical Control Electronics connected · New Outer Blanket Layer, and coronagraph ­ Solar Blind Channel (SBC) : HST's most sensitive ultraviolet photon-counting detector 115-180 nm

Sirianni, Marco

98

Appendix AC Exceptions to Delegated Purchasing Authority  

E-Print Network [OSTI]

Appendix AC Exceptions to Delegated Purchasing Authority Delegated purchasing authority for professions exempted by 18-4-132, MCA The following services are exempt from Purchasing Procedures per Montana provider - Expert witness hired for use in litigation, Hearings Officer hired in rulemaking and contested

Dyer, Bill

99

AC Solar Inc | Open Energy Information  

Open Energy Info (EERE)

Logo: AC Solar Inc Name AC Solar Inc Address P.O. Box 128 Place Florence, Colorado Zip 81226 Sector Solar Product Solar and wind sales for residential Website http://www.acsolar.com/ Coordinates 38.381551°, -105.112265° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.381551,"lon":-105.112265,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

100

Direct amplitude detuning measurement with ac dipole  

DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

In circular machines, nonlinear dynamics can impact parameters such as beam lifetime and could result in limitations on the performance reach of the accelerator. Assessing and understanding these effects in experiments is essential to confirm the accuracy of the magnetic model and improve the machine performance. A direct measurement of the machine nonlinearities can be obtained by characterizing the dependency of the tune as a function of the amplitude of oscillations (usually defined as amplitude detuning). The conventional technique is to excite the beam to large amplitudes with a single kick and derive the tune from turn-by-turn data acquired with beam position monitors. Although this provides a very precise tune measurement it has the significant disadvantage of being destructive. An alternative, nondestructive way of exciting large amplitude oscillations is to use an ac dipole. The perturbation Hamiltonian in the presence of an ac dipole excitation shows a distinct behavior compared to the free oscillations which should be correctly taken into account in the interpretation of experimental data. The use of an ac dipole for direct amplitude detuning measurement requires careful data processing allowing one to observe the natural tune of the machine; the feasibility of such a measurement is demonstrated using experimental data from the Large Hadron Collider. An experimental proof of the theoretical derivations based on measurements performed at injection energy is provided as well as an application of this technique at top energy using a large number of excitations on the same beam.

White, S.; Maclean, E.; Toms, R.

2013-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

www.sheffield.ac.uk/careers Develop Your  

E-Print Network [OSTI]

Marketplace' run by the Careers Service and HSBC Bank www.shef. ac.uk/careers/students/advice/sfs. 10. If you

Martin, Stephen John

102

The Impact of Best Track Discrepancies on Global Tropical Cyclone Climatologies using IBTrACS  

Science Journals Connector (OSTI)

Using the International Best Track Archive for Climate Stewardship (IBTrACS), the climatology of tropical cyclones is compared between two global best track datasets: 1) the World Meteorological Organization (WMO) subset of IBTrACS (IBTrACS-WMO) ...

Carl J. Schreck III; Kenneth R. Knapp; James P. Kossin

2014-10-01T23:59:59.000Z

103

E-Print Network 3.0 - ac voltage standard Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

"volts, AC"), the "secondary" voltage is roughly 6 VAC. We shall use the "Universal Transformer... :" conversion of AC to DC You can use a diode to convert the AC voltage of the...

104

E-Print Network 3.0 - ac systems Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: -6261 E-mail: kuni@mind.c.u-tokyo.ac.jp http:mind.c.u-tokyo.ac.jpindex-j.html 1890 20 Systems... 12;1 4647 4025 http:bio.c.u-tokyo.ac... ......

105

E-Print Network 3.0 - ac graftrope system Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: -6261 E-mail: kuni@mind.c.u-tokyo.ac.jp http:mind.c.u-tokyo.ac.jpindex-j.html 1890 20 Systems... 12;1 4647 4025 http:bio.c.u-tokyo.ac... ......

106

E-Print Network 3.0 - ac conduction properties Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

measure the dynamical conductance of electrically contacted single-walled carbon nanotubes at dc and ac... between the ac ... Source: Burke, Peter - Department of Electrical...

107

AVTA: Siemens-VersiCharge AC Level 2 Charging System Testing...  

Broader source: Energy.gov (indexed) [DOE]

Siemens-VersiCharge AC Level 2 Charging System Testing Results AVTA: Siemens-VersiCharge AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced...

108

56TH ACS NORTHWEST REGIONAL MEETING  

Science Journals Connector (OSTI)

56TH ACS NORTHWEST REGIONAL MEETING ... Several plenary sessions and interdisciplinary public lectures will address this theme, including "Technology for the 21st Century," presented by Lura J. Powell, director, Pacific Northwest National Laboratory; "DNA and Molecular Recognition," presented by Jacqueline Barton, California Institute of Technology; "Bioengineering Tissues," presented by Buddy Ratner, University of Washington; "History and Chemistry of Plutonium Extraction at Hanford," presented by Earl Wheelwright, Pacific Northwest National Laboratory; "Life in the Universe," presented by Donald Brownlee, University ofWashington; "Climate Change: How Will It Affect the Pacific Northwest?" presented by Jae Edmonds, Pacific Northwest National Laboratory; and "The Future of Science Education," presented by ... ...

2001-05-14T23:59:59.000Z

109

www.mmu.ac.uk/careers Careers & Employability Service  

E-Print Network [OSTI]

to prepare? Alison Proudlove Thursday, June 07, 2012 1 #12;www.mmu.ac.uk/careers What will we cover researched the organisation #12;www.mmu.ac.uk/careers Use your time wisely · If there are large queues , have

110

Electrostatic coalescence system with independent AC and DC hydrophilic electrodes  

DOE Patents [OSTI]

An improved electrostatic coalescence system is provided in which independent AC and DC hydrophilic electrodes are employed to provide more complete dehydration of an oil emulsion. The AC field is produced between an AC electrode array and the water-oil interface wherein the AC electrode array is positioned parallel to the interface which acts as a grounded electrode. The emulsion is introduced into the AC field in an evenly distributed manner at the interface. The AC field promotes drop-drop and drop-interface coalescence of the water phase in the entering emulsion. The continuous oil phase passes upward through the perforated AC electrode array and enters a strong DC field produced between closely spaced DC electrodes in which small dispersed droplets of water entrained in the continuous phase are removed primarily by collection at hydrophilic DC electrodes. Large droplets of water collected by the electrodes migrate downward through the AC electrode array to the interface. All phase separation mechanisms are utilized to accomplish more complete phase separation.

Hovarongkura, A. David (Arlington, VA); Henry, Jr., Joseph D. (Morgantown, WV)

1981-01-01T23:59:59.000Z

111

IT Services go.warwick.ac.uk/whatsnew2010  

E-Print Network [OSTI]

to enable us to develop it as you would like. https://start.warwick.ac.uk/ Warwick Forward Warwick Forward. The domain itself must be registered with an external company by you. http://forward.warwick.ac.uk/ Files to navigate. · Files Transfer Utility. Enable access via a drive letter in Windows Explorer (or equivalent

Davies, Christopher

112

Applied Cognitive Science (ACS) The ACS lab is directed by Dr. Frank Ritter, professor of IST and  

E-Print Network [OSTI]

Applied Cognitive Science (ACS) Laboratory The ACS lab is directed by Dr. Frank Ritter, professor during the 2012-2013 academic year, studies cognitive modeling, cognitive architectures, human-computer interaction (HCI), and learning. He has taught cognitive modeling, cognitive architectures, HCI, human factors

Squicciarini, Anna Cinzia

113

E-Print Network 3.0 - ac transmission lines Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

lines Search Powered by Explorit Topic List Advanced Search Sample search results for: ac transmission lines...

114

E-Print Network 3.0 - ac transmission line Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

line Search Powered by Explorit Topic List Advanced Search Sample search results for: ac transmission line...

115

Optimal design of AC filter circuits in HVDC converter stations  

SciTech Connect (OSTI)

This paper investigates the reactive power as well as the harmonic conditions on both the valve and the AC-network sides of a HVDC converter station. The effect of the AC filter circuits is accurately modeled. The program is then augmented by adding an optimization routine. It can identify the optimal filter configuration, yielding the minimum current distortion factor at the AC network terminals for a prespecified fundamental reactive power to be provided by the filter. Several parameter studies were also conducted to illustrate the effect of accidental or intentional deletion of one of the filter branches.

Saied, M.M.; Khader, S.A. [Kuwait Univ. (Kuwait). Electrical and Computer Engineering Dept.

1995-12-31T23:59:59.000Z

116

Contract Number: DE-AC05-76RL01830 Modification M705  

E-Print Network [OSTI]

#12;#12;Contract Number: DE-AC05-76RL01830 Modification M705 #12;Contract Number: DE-AC05-76RL01830 Modification M705 #12;Contract Number: DE-AC05-76RL01830 Modification M705 #12;Contract Number: DE-AC05-76RL01830 Modification M705 #12;Contract Number: DE-AC05-76RL01830 Modification M705 #12;Contract Number: DE

117

www.kent.ac.uk/is/ Information Services  

E-Print Network [OSTI]

.kent.ac.uk/cmsds-local/ Installing `Putty' Download it from the web (if you have administrator privilages) www close to each other. A dark cursor will not show on a dark background. Ideally make either

Banaji,. Murad

118

Cognitive Radio Network {swjang, sbahk}@netlab.snu.ac.kr  

E-Print Network [OSTI]

2010 Cognitive Radio Network , , {swjang, sbahk}@netlab.snu.ac.kr Analysis of Average Opportunities in Cognitive Radio Networks Seowoo Jang, Saewoong Bahk INMC, EECS, Seoul National University Cognitive Radio Network . Primary user

Bahk, Saewoong

119

INTERPRETATION OF AC IMPEDANCE MEASUREMENTS IN SOLIDS* J. Ross Macdonald  

E-Print Network [OSTI]

= INTERPRETATION OF AC IMPEDANCE MEASUREMENTS IN SOLIDS* J. Ross Macdonald Department of Physics Foundation (Grant No. DMR 75-10739). 81 #12;82 PERTINENT PARAMETERS J.R. MACDONALD Figure 1 shows

Macdonald, James Ross

120

David M. Frohlich d.frohlich@surrey.ac.uk  

E-Print Network [OSTI]

19 David M. Frohlich d.frohlich@surrey.ac.uk Professor & Director, Digital World Research Centre in Community Content Creation FROHLICH, BHAT, JONES, LALMAS, FRANK, RACHOVIDES, TUCKER, RIGA Research Article

Lalmas, Mounia

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Contract Number DE-AC27-10RV15051  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Section H.26, Key Personnel, Pages i and H-32 Section J, Attachment 7, Performance Evaluation and Measurement Plan, Page J-127 222-S LAS&T Contract No. DE-AC27-10RV15051...

122

Microfluidics {sjauh, btzhang}@bi.snu.ac.kr  

E-Print Network [OSTI]

Microfluidics {sjauh, btzhang}@bi.snu.ac.kr Solving Shortest Path Problems Using Microfluidics Sahng-Joon Auh and Byoung-Tak Zhang Biointelligence Lab, School of Computer Science and Engineering Seoul National University . microfluidics MEMS

123

www.glasgow.ac.uk/parents Say hello to Glasgow  

E-Print Network [OSTI]

Parents' Guide www.glasgow.ac.uk/parents #12;2 Welcome Say hello to Glasgow Choosing the right Satisfaction (National Student Survey). Contents Page 2 Welcome Say hello to Glasgow Pages3

Guo, Zaoyang

124

SVC implementation using neural networks for an AC electrical railway  

Science Journals Connector (OSTI)

This paper presents an on-line method for implementation of a static var compensator (SVC) in a real ac autotransformer (AT)-fed electrical railway for reactive power compensation using Neural Networks (NN). Genetic algorithm (GA) can be the off-line ... Keywords: AC electrical railways load flow, forward/backward sweep (FBS), genetic algorithm (GA), neural network (NN), reactive power compensation, static var compensator (SVC)

Saeid Veysi Raygani; Bijan Moaveni; Seyed Saeed Fazel; Amir Tahavorgar

2011-05-01T23:59:59.000Z

125

Development of an AC Module System: Final Technical Report  

SciTech Connect (OSTI)

The GreenRay Inc. program focused on simplifying solar electricity and making it affordable and accessible to the mainstream population. This was accomplished by integrating a solar module, micro-inverter, mounting and monitoring into a reliable, 'plug and play' AC system for residential rooftops, offering the following advantages: (1) Reduced Cost: Reduction in installation labor with fewer components, faster mounting, faster wiring. (2) Maximized Energy Production: Each AC Module operates at its maximum, reducing overall losses from shading, mismatch, or module downtime. (3) Increased Safety. Electrical and fire safety experts agree that AC Modules have significant benefits, with no energized wiring or live connections during installation, maintenance or emergency conditions. (4) Simplified PV for a Broader Group of Installers. Dramatic simplification of design and installation of a solar power system, enabling faster and more efficient delivery of the product into the market through well-established, mainstream channels. This makes solar more accessible to the public. (5) Broadened the Rooftop Market: AC Modules enable solar for many homes that have shading, split roofs, or obstructions. In addition, due to the smaller building block size of 200W vs. 1000W, homeowners with budget limitations can start small and add to their systems over time. Through this DOE program GreenRay developed the all-in-one AC Module system with an integrated PV Module and microinverter, custom residential mounting and performance monitoring. Development efforts took the product from its initial concept, through prototypes, to a commercial product sold and deployed in the residential market. This pilot deployment has demonstrated the technical effectiveness of the AC Module system in meeting the needs and solving the problems of the residential market. While more expensive than the traditional central inverter systems at the pilot scale, the economics of AC Modules become more and more favorable as the product matures and is made in high volumes. GreenRay's early customers have been highly enthusiastic about the AC Module system benefits.

Suparna Kadam; Miles Russell

2012-06-15T23:59:59.000Z

126

Installation considerations for IGBT AC drives  

SciTech Connect (OSTI)

In the last four years, Adjustable Speed ac Drive (ASD) manufacturers have migrated from Bipolar Junction Transistor (BJT) semiconductors to Insulated Gate Bipolar Transistors (IGBTs) as the preferred Output switching device. The advantage of IGBTs over BJTs is that device rise and fall time switching capability is 5 - 10 times faster, resulting in lower device switching loss and a more efficient drive. However, for a similar motor cable length as the BJT drive, the faster output voltage risetime of the IGBT drive may increase the dielectric voltage stress on the motor and cable due to a phenomenon called reflected wave. Faster output dv/dt transitions of IGBT drives also increase the possibility for phenomenon such as increased Common Mode (CM) electrical noise, Electromagnetic Interference (EMI) problems and increased capacitive cable charging current problems. Also, recent experience suggests any Pulse Width Modulated (PWM) drive with a steep fronted output voltage wave form may increase motor shaft voltage and lead to a bearing current phenomenon known as fluting. This paper provides a basic understanding of these issues, as well as solutions, to insure a successful drive system installation.

Skibinski, G.L.

1997-06-01T23:59:59.000Z

127

Where has Electricity Demand Growth Gon in PJM and What are the...  

U.S. Energy Information Administration (EIA) Indexed Site

economic conditions and environmental rules - New entry of combined cycle gas and demand response resources...will there be incentives for continued new entry? * Impending GHG...

128

AC Loss Measurements on a 2G YBCO Coil  

SciTech Connect (OSTI)

The Oak Ridge National Laboratory (ORNL) is collaborating with Waukesha Electric Systems (WES) to continue development of HTS power transformers. For compatibility with the existing power grid, a commercially viable HTS transformer will have to operate at high voltages in the range of 138 kV and above, and will have to withstand 550-kV impulse voltages as well. Second-generation (2G) YBCO coated conductors will be required for an economically-competitive design. In order to adequately size the refrigeration system for these transformers, the ac loss of these HTS coils must be characterized. Electrical AC loss measurements were conducted on a prototype high voltage (HV) coil with co-wound stainless steel at 60 Hz in a liquid nitrogen bath using a lock-in amplifier technique. The prototype HV coil consisted of 26 continuous (without splice) single pancake coils concentrically centered on a stainless steel former. For ac loss measurement purposes, voltage tap pairs were soldered across each set of two single pancake coils so that a total of 13 separate voltage measurements could be made across the entire length of the coil. AC loss measurements were taken as a function of ac excitation current. Results show that the loss is primarily concentrated at the ends of the coil where the operating fraction of critical current is the highest and show a distinct difference in current scaling of the losses between low current and high current regimes.

Rey, Christopher M [ORNL] [ORNL; Duckworth, Robert C [ORNL] [ORNL; Schwenterly, S W [ORNL] [ORNL

2011-01-01T23:59:59.000Z

129

E-Print Network 3.0 - ac metal-enclosed switchgear Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Anne 2011 Prsente devant Summary: -design; Transmission System; Life Cycle Assessment (LCA); 765 kV AC; 1000 kV AC; Ultra High Voltage; Extra High Voltage... Acidification AAC...

130

Docket No. EERE-2011-BT-NOA-0067 and RIN Number 1904-AC52 Ex...  

Broader source: Energy.gov (indexed) [DOE]

1-BT-NOA-0067 and RIN Number 1904-AC52 Ex parte Communication Docket No. EERE-2011-BT-NOA-0067 and RIN Number 1904-AC52 Ex parte Communication This memorandum for the record...

131

AVTA Voltec AC Level 1 and Level 2 Charging Systems Testing Results...  

Broader source: Energy.gov (indexed) [DOE]

AVTA Voltec AC Level 1 and Level 2 Charging Systems Testing Results AVTA Voltec AC Level 1 and Level 2 Charging Systems Testing Results The Vehicle Technologies Office's Advanced...

132

AVTA: GE Energy WattStation AC Level 2 Charging System Testing...  

Broader source: Energy.gov (indexed) [DOE]

GE Energy WattStation AC Level 2 Charging System Testing Results AVTA: GE Energy WattStation AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced...

133

AVTA: ChargePoint AC Level 2 Charging System Testing Results...  

Broader source: Energy.gov (indexed) [DOE]

AVTA: ChargePoint AC Level 2 Charging System Testing Results AVTA: ChargePoint AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced Vehicle Testing...

134

Breathing HRV by the Concept of AC Ventilation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Breathing HRV by the Concept of AC Ventilation Breathing HRV by the Concept of AC Ventilation Speaker(s): Hwataik Han Date: July 10, 2007 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Thomas McKone Heat recovery ventilators are frequently used to save heating/cooling loads of buildings for ventilation. There are several types of HRV's, including a parallel plate type, a rotary type, a capillary type, and a heat pipe type. The breathing HRV is a heat recovery ventilator of a new kind using the concept of alternating-current ventilation. The AC ventilation is the ventilation with the airflow directions reversed periodically. It has an advantage of using a single duct system, for both supply and exhaust purposes. In order to develop a breathing HRV system, the thermal recovery performance should be investigated depending on many parameters, such as

135

Boys and Girls, Be Ambitious! http://www.math.sci.hokudai.ac.jp/message/message-graduates/  

E-Print Network [OSTI]

://www.math.sci.hokudai.ac.jp/ #12;AIKAWA, Hiroaki WebPage http://www.math.sci.hokudai.ac.jp/ aik/index-j.html Fatou Martin Harnack AKITA, Toshiyuki WebPage http://www.math.sci.hokudai.ac.jp/ akita/ Eilenberg-MacLane Coxeter #12;ASAKURA, Masanori ARAI, Asao ABE, Noriyuki WebPage http://www.math.sci.hokudai.ac.jp/ abenori/ #12;ISHIKAWA, Goo Web

Nakamura, Iku

136

Sarah.Glynn@ed.ac.uk April 2008 Liberalising Islam: creating Brits of the Islamic Persuasion  

E-Print Network [OSTI]

.Glynn@ed.ac.uk April 2008 1 Liberalising Islam: creating Brits of the Islamic Persuasion In common with other

137

DE-AC05-06OR23100 Section H  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DE-AC05-06OR23100 DE-AC05-06OR23100 Section H - Page 1 of 29 PART I - SCHEDULE SECTION H SPECIAL CONTRACT REQUIREMENTS H.1 CONSECUTIVE NUMBERING (MAY 1997)......................................................................... 4 H.2 MODIFICATION AUTHORITY (MAY 1997) ....................................................................... 4 H.3 OVERSIGHT OF CONTRACTOR (OCT 2004)..................................................................... 4 H.4 SMALL BUSINESS SUBCONTRACTING PLAN (SEPT 1999)............................................ 5 H.5 SAFEGUARDS AND SECURITY AWARENESS PROGRAM (MAY 1997)........................ 5 H.6 QUALITY ASSURANCE SYSTEM ALTERNATE I (JUL 2004).......................................... 5 H.7 CONFIDENTIALITY OF INFORMATION (MAY 1997)...................................................... 6 H.8 INDIRECT

138

Study of AC/RF properties of SRF ingot niobium  

SciTech Connect (OSTI)

In an attempt to correlate the performance of superconducting radiofrequency cavities made of niobium with the superconducting properties, we present the results of the magnetization and ac susceptibility of the niobium used in the superconducting radiofrequency cavity fabrication. The samples were subjected to buffer chemical polishing (BCP) surface and high temperature heat treatments, typically applied to the cavities fabrications. The analysis of the results show the different surface and bulk ac conductivity for the samples subjected to BCP and heat treatment. Furthermore, the RF surface impedance is measured on the sample using a TE011 microwave cavity for a comparison to the low frequency measurements.

Dhakal, Pashupati; Tsindlekht, Menachem I.; Genkin, Valery M.; Ciovati, Gianluigi; Myneni, Ganapati Rao

2013-09-01T23:59:59.000Z

139

(mercury.yukawa.kyoto-u.ac.jp)ssh Permission denied (publickey).  

E-Print Network [OSTI]

SSH Q&A (mercury.yukawa.kyoto-u.ac.jp)ssh Permission denied (publickey). (1) ID ID ID (2) ssh -i () ssh -i $HOME/.ssh/id_yitp_rsa (UID)@mercury.yukawa.kyoto-u.ac.jp (3) (1)(2) Permission denied support@yukawa.kyoto-u.ac.jp (mercury

Shimizu, Akira

140

Contract No. DE-AC05-76RL01830 Modification M943  

E-Print Network [OSTI]

Contract No. DE-AC05-76RL01830 Modification M943 SECTION J APPENDIX A ADVANCE UNDERSTANDINGS ON HUMAN RESOURCES COST Applicable to the Operation of PACIFIC NORTHWEST NATIONAL LABORATORY Contract No. DE-AC05-76RL01830 #12;Contract No. DE-AC05-76RL01830 Modification M943 J-A-1 Table of Contents

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Contract Number: DE-AC05-76RL01830 Modification M957  

E-Print Network [OSTI]

Contract Number: DE-AC05-76RL01830 Modification M957 APPENDIX E STANDARDS OF PERFORMANCE-BASED FEE OF THE PACIFIC NORTHWEST NATIONAL LABORATORY #12;Contract Number: DE-AC05-76RL01830 Modification M957 APPENDIX E FOR MANAGEMENT AND OPERATIONS OF THE PACIFIC NORTHWEST NATIONAL LABORATORY #12;Contract Number: DE-AC05-76RL01830

142

Allianz Climate Solutions ACS GmbH | Open Energy Information  

Open Energy Info (EERE)

Allianz Climate Solutions ACS GmbH Allianz Climate Solutions ACS GmbH Jump to: navigation, search Name Allianz Climate Solutions (ACS) GmbH Place Munich, Germany Zip 80802 Product Munich-based subsidiary of insurance and asset management provider Allianz SE. ACS acts as investment manager, service provider and advisor of climate solutions for Allianz Group and external customers. Coordinates 48.136415°, 11.577531° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":48.136415,"lon":11.577531,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

143

www.cardiff.ac.uk/annualreview2013 ANNUALREVIEW  

E-Print Network [OSTI]

www.cardiff.ac.uk/annualreview2013 2013 ANNUALREVIEW #12;2 The Way Forward outlines our ambition, I must mention one key project that has occupied the time and energy of many staff in Schools's energy challenges and tackling the lasting effects of industrial activity. Individuals too, were singled

Davies, Christopher

144

FBDEditor: {ldalove, atang34, syjsmk, jbyoo}@konkuk.ac.kr  

E-Print Network [OSTI]

}@konkuk.ac.kr : Programmable Logic Controller (PLC) . Field Programmable Gate Array (FPGA) . PLC Function Controller (PLC) Field Programmable Gate Array (FPGA) . PLC IEC 61131-3 5 (LD: Ladder diagram) . FBD Function Block(FB) . FBD PLC . FPGA Hardware Description Language

145

www.cardiff.ac.uk/ifp International Foundation  

E-Print Network [OSTI]

www.cardiff.ac.uk/ifp International Foundation Programme Business, Engineering, Health & Life Sciences #12;Welcome to the International Foundation Programme at Cardiff University What is the IFP? The International Foundation Programme (IFP) is a one-year academic programme designed to give you the academic

Davies, Christopher

146

www.eprg.group.cam.ac.uk EPRGWORKINGPAPER  

E-Print Network [OSTI]

www.eprg.group.cam.ac.uk EPRGWORKINGPAPER Abstract Nuclear Energy in the Enlarged European Union of nuclear energy and notes that it has shifted significantly as the European Union has grown from 15 member states to 27. The proportion of member states with nuclear energy experience has increased markedly. Also

Aickelin, Uwe

147

www.eprg.group.cam.ac.uk EPRGWORKINGPAPERNON-TECHNICALSUMMARY  

E-Print Network [OSTI]

www.eprg.group.cam.ac.uk EPRGWORKINGPAPERNON-TECHNICALSUMMARY Third Party Nuclear Liability 1207 Anthony Thomas and Raphael J. Heffron With a return to nuclear new build expected in the UK, the clarification of the position of a Supplier and their potential to be liable for nuclear damage is of vital

Aickelin, Uwe

148

www.eprg.group.cam.ac.uk EPRGWORKINGPAPERNON-TECHNICALSUMMARY  

E-Print Network [OSTI]

www.eprg.group.cam.ac.uk EPRGWORKINGPAPERNON-TECHNICALSUMMARY Nuclear Energy in the Enlarged in central and eastern Europe for nuclear power. This working paper notes that with the addition of 12 new significantly in favour of nuclear power. Furthermore several of these central and eastern EU countries have

Aickelin, Uwe

149

www.eprg.group.cam.ac.uk EPRGWORKINGPAPER  

E-Print Network [OSTI]

www.eprg.group.cam.ac.uk EPRGWORKINGPAPER Abstract Third Party Nuclear Liability: The Case Thomas and Raphael J. Heffron The law surrounding third party nuclear liability is important to all parties in the nuclear supply chain whether they are providing decommissioning services, project

Aickelin, Uwe

150

www.eprg.group.cam.ac.uk EPRGWORKINGPAPER  

E-Print Network [OSTI]

) falls and energy prices rises in one country may have little effect at the world level. Next, we examinewww.eprg.group.cam.ac.uk EPRGWORKINGPAPER Abstract The Economics of Energy (and Electricity) Demand-term trends of both energy and more specifically electricity consumption. This paper discusses some

Aickelin, Uwe

151

www.strath.ac.uk/engineering Faculty of Engineering  

E-Print Network [OSTI]

. The Faculty of Engineering wishes to thank all of our industrial partners who offer invaluable opportunitieswww.strath.ac.uk/engineering @StrathEng Faculty of Engineering Scholarships #12;Contents University of Strathclyde | Faculty of Engineering Scholarships Contents02 The Faculty of Engineering provides a wide range

Mottram, Nigel

152

Aircraft AC Generators: Hybrid System Modeling and Simulation  

E-Print Network [OSTI]

1 Aircraft AC Generators: Hybrid System Modeling and Simulation Ashraf Tantawy, Student Member--Integrated Drive Generators (IDGs) are the main source of electrical power for a number of critical systems is a difficult task. dq0 models have been developed for design and control of generators, but these models

Koutsoukos, Xenofon D.

153

Contract No. DE-AC27-IORV15051  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Testing TOTAL 67,635,770.56 27,484,734.04 Page 2 of 5 Contract No. DE-AC27-10RV15051 Modification No. 49 SF-30 Continuation 3. The table in Contract Clause B.1, Type...

154

www.eprg.group.cam.ac.uk EPRGWORKINGPAPERNON-TECHNICALSUMMARY  

E-Print Network [OSTI]

www.eprg.group.cam.ac.uk EPRGWORKINGPAPERNON-TECHNICALSUMMARY The Economics of the Nord Stream with the construction of the Yamal-Europe pipeline in the 1990s and continued more recently with the Nord Stream west-European clients. The Nord Stream project has been politically controversial since its inception

Aickelin, Uwe

155

www.eprg.group.cam.ac.uk EPRGWORKINGPAPER  

E-Print Network [OSTI]

www.eprg.group.cam.ac.uk EPRGWORKINGPAPER Abstract The Economics of the Nord Stream Pipeline System M. Reiner We calculate the total cost of building Nord Stream and compare its levelised unit cost of shipping through Nord Stream is clearly lower than using the Ukrainian route and is only

Aickelin, Uwe

156

www.abdn.ac.uk/study Global Health  

E-Print Network [OSTI]

www.abdn.ac.uk/study Global Health & Management Master of Science/Postgraduate Diploma MSc/PgDip #12;The programme begins with cross-disciplinary Public Health Research training (Applied Statistics, Epidemiology, Qualitative Methods, Health Services Research and Systematic Reviewing) followed by courses

Levi, Ran

157

http://stir.ac.uk/4o Why study Marketing?  

E-Print Network [OSTI]

http://stir.ac.uk/4o BA(Hons) Marketing #12;Why study Marketing? Every business has end users, then Marketing may be the right degree for you. The course As you progress through your Marketing degree, you in a business setting. Team work ­ working in a group is an essential part of your Marketing degree, both during

Little, Tony

158

Carbon Nanotube Field-effect Transistors: AC Performance Capabilities.  

E-Print Network [OSTI]

Carbon Nanotube Field-effect Transistors: AC Performance Capabilities. D.L. Pulfrey, D.L. John-barrier carbon nanotube field-effect transistors are examined via simulations using a self-consistent Schrödinger is known about the DC capabilities of carbon nanotube field-effect transistors [1,2,3], and devices

Pulfrey, David L.

159

www.glasgow.ac.uk/library The University Library  

E-Print Network [OSTI]

www.glasgow.ac.uk/library The University Library for staff #12;www.facebook.com/uofglibrary twitter.com/uofglibrary instagram.com/uoglibrary Library Blog universityofglasgowlibrary.wordpress.com Welcome to the University Library Where is the Library? It's on Hillhead Street, next to the Hunterian Art Gallery, at the heart

Guo, Zaoyang

160

www.swansea.ac.uk Health & Safety Office  

E-Print Network [OSTI]

to a manageable / acceptable (safer) level. #12;www.swansea.ac.uk Health & Safety Office Hazard & Risk #12;www the control measures required to reduce or eliminate the risk to a manageable / acceptable (safer) level. #12 for hazard identification and associated Risk Assessment To be able to identify Hazards and recommend

Martin, Ralph R.

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

ACS WFC CCD Radiation Test: The Radiation Environment  

E-Print Network [OSTI]

of external surfaces by naturally occurring atomic oxygen. CCD detectors are particularly vulnerable to damage damage. A comprehensive discussion of the types of radiation damage known to occur in CCDs is beyond1 ACS WFC CCD Radiation Test: The Radiation Environment Michael R. Jones Space Telescope Science

Sirianni, Marco

162

Efficiency Ratings for the Daiken AC (Americas), Inc.  

E-Print Network [OSTI]

Efficiency Ratings for the Daiken AC (Americas), Inc. Altherma Air-to-Water Source Heat Pump System Description Model No. Capacity (tons) Space Heating Space Cooling SEER Water Heating Efficiency (E.F.)1 CEC Listing Date Heating Combined Hydronic HSPF E.F. Split Altherma LT ERLQ036

163

2D 3D * iklee)@yonsei.ac.kr  

E-Print Network [OSTI]

1 2012 2D 3D * 0 , 1 , 2 0,2 1 ( 0 skrcjstk, 2 iklee)@yonsei.ac.kr 1 rinthel Science, Yonsei University. 1 Dept. of Information Media, The University of Suwon. 2D 3D . 2D - , 3D (Disparity) 3D . . 1. 3D 3D . 3D 3D [1

Lee, In-Kwon

164

DE-AC27-08RV14800  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

SOLUTIONS LLC (A) (B) (C) (D) (E) (F) DE-AC27-08RV14800026 4. 1,860,841.43 for Rocky Flats Pension and PRB 5. 1,139,022.27 for Mound Pension and PRB and 6. 183,364.11...

165

Village of Versailles, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Versailles, Ohio (Utility Company) Versailles, Ohio (Utility Company) Jump to: navigation, search Name Village of Versailles Place Ohio Utility Id 19805 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Demand (High Load Factor)-Inside village limits -Primary Metering Adjustment Commercial Commercial Demand (High Load Factor)-Inside village limits Commercial Commercial Demand (High Load Factor)-Outside village limits -Primary metering adjustment Commercial

166

Hancock-Wood Electric Coop Inc | Open Energy Information  

Open Energy Info (EERE)

Hancock-Wood Electric Coop Inc Hancock-Wood Electric Coop Inc Jump to: navigation, search Name Hancock-Wood Electric Coop Inc Place Ohio Utility Id 8034 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Farm Service-R-107 Commercial Farm Sevice R-207 Commercial Farm Sevice R-207(Transformer Capacity in Excess of 25kVA) Commercial LPS Rate 12 (Mainland) Industrial LPS Rate 12KI (Kelleys Island) Industrial NR Rate GS-8KI (Kelleys Island) Commercial NR Rate GS-8M (Mainland) Commercial NR Rate GS-9KI - Kelleys Island Over 25 kW Commercial

167

Borough of Chambersburg, Pennsylvania (Utility Company) | Open Energy  

Open Energy Info (EERE)

Chambersburg, Pennsylvania (Utility Company) Chambersburg, Pennsylvania (Utility Company) Jump to: navigation, search Name Borough of Chambersburg Place Pennsylvania Utility Id 3329 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Area Lighting Rate- (1000W HPS) Lighting Area Lighting Rate- (1000W Mercury Vapor) Lighting Area Lighting Rate- (100W HPS Flood) Lighting Area Lighting Rate- (100W HPS) Lighting Area Lighting Rate- (175W Mercury Vapor) Lighting

168

PEPCO Energy Services | Open Energy Information  

Open Energy Info (EERE)

PEPCO (DC)) PEPCO (DC)) Jump to: navigation, search Name PEPCO Energy Services Place Virginia Utility Id 14405 Utility Location Yes Ownership R NERC Location RFC NERC ERCOT Yes NERC RFC Yes ISO Ercot Yes RTO PJM Yes ISO NY Yes ISO NE Yes Activity Retail Marketing Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png R Residential RTM Residential Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=PEPCO_Energy_Services&oldid=411295"

169

DTE Energy Trading, Inc | Open Energy Information  

Open Energy Info (EERE)

Trading, Inc Trading, Inc Jump to: navigation, search Name DTE Energy Trading, Inc Place Michigan Utility Id 25262 Utility Location Yes Ownership W NERC Location RFC NERC ERCOT Yes NERC RFC Yes ISO Ercot Yes RTO PJM Yes ISO NY Yes ISO MISO Yes ISO NE Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=DTE_Energy_Trading,_Inc&oldid=410556"

170

Potomac Electric Power Co | Open Energy Information  

Open Energy Info (EERE)

Potomac Electric Power Company (PEPCO)) Potomac Electric Power Company (PEPCO)) Jump to: navigation, search Name Potomac Electric Power Co Place District of Columbia Service Territory District of Columbia, Maryland Website www.pepco.com/home/ Green Button Landing Page www.pepco.com/home/billin Green Button Reference Page www.pepcoholdings.com/abo Green Button Implemented Yes Utility Id 15270 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] SGIC[3] LinkedIn Connections

171

Ohio Power Co | Open Energy Information  

Open Energy Info (EERE)

Power Co Power Co Place Ohio Website www.aepohio.com Utility Id 14006 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png GS-1 (Small General Service) Commercial GS-2 (Medium General Service Secondary) Commercial GS-TOD Commercial GS-TOD (General Service Time-Of-Day) Commercial

172

City of Vanceburg, Kentucky (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Vanceburg, Kentucky (Utility Company) Vanceburg, Kentucky (Utility Company) Jump to: navigation, search Name City of Vanceburg Place Kentucky Utility Id 19716 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Rate EL-04 Commercial Fixed Load Rate EL-07 Residential Industrial Demand DE-08 Industrial Industrial Rate EL-05 Industrial Outside Lighting EL-2A (150W) Lighting Outside Lighting EL-2B (150W with Pole) Lighting Outside Lighting EL-2C (400W) Lighting Outside Lighting EL-2D (400W with Pole) Lighting

173

Borough of Park Ridge, New Jersey (Utility Company) | Open Energy  

Open Energy Info (EERE)

Jersey (Utility Company) Jersey (Utility Company) Jump to: navigation, search Name Borough of Park Ridge Place New Jersey Utility Id 14472 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Dusk to Dawn Floodlight Service MV 1000W Lighting Dusk to Dawn Floodlight Service HPS 100W Lighting Dusk to Dawn Floodlight Service HPS 150W Lighting Dusk to Dawn Floodlight Service HPS 175W Lighting Dusk to Dawn Floodlight Service HPS 250W Lighting Dusk to Dawn Floodlight Service HPS 360W Lighting Dusk to Dawn Floodlight Service HPS 400W Lighting

174

Borough of Butler, New Jersey (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Borough of Butler, New Jersey (Utility Company) Borough of Butler, New Jersey (Utility Company) Jump to: navigation, search Name Borough of Butler Place New Jersey Utility Id 2650 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100W Floodlight Base Rate Inside Butler Lighting 100W Floodlight Base Rate Outside Butler Lighting 175W Floodlight Base Rate Inside Butler Lighting 175W Floodlight Base Rate Outside Butler Lighting 250W Floodlight Base Rate Inside Butler Lighting 250W Floodlight Base Rate Outside Butler Lighting

175

City of Bryan, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Bryan Bryan Place Ohio Utility Id 2439 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Electric Rates Commercial Commercial outside service Commercial Residential Service Inside City Limits Residential Residential Service Outside City Limits Residential Average Rates Residential: $0.1030/kWh Commercial: $0.1190/kWh Industrial: $0.0888/kWh

176

United Electric Coop, Inc (Pennsylvania) | Open Energy Information  

Open Energy Info (EERE)

United Electric Coop, Inc United Electric Coop, Inc Place Pennsylvania Utility Id 40219 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Service - Multi-Phase - Unbundled Commercial General Service - Single Phase - Unbundled Commercial General Service Multi- Phase Commercial General Service Single Phase Commercial Home Comfort Service Commercial Large Power Service - Unbundled Industrial Large Power Sevice Industrial Residential Service - Unbundled Residential Residential Single-Phase Residential

177

Central Electric Coop, Inc (Pennsylvania) | Open Energy Information  

Open Energy Info (EERE)

Pennsylvania) Pennsylvania) Jump to: navigation, search Name Central Electric Coop, Inc Place Pennsylvania Utility Id 40224 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Service Residential Large Commercial Commercial Large Commercial - Self Generation Commercial Large Commercial(Primary metering) Commercial Load Control Residential Seasonal Residential Security Light - HPS Flood Light Lighting Security Light Large Lighting Security Light Large Street Lighting Security Light Small Lighting

178

Commonwealth Edison Co | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search Jump to: navigation, search Name Commonwealth Edison Co Place Illinois Service Territory Illinois Website www.comed.com/Pages/defau Green Button Reference Page www.whitehouse.gov/admini Green Button Committed Yes Utility Id 4110 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 1 Residential

179

Clyde Light & Power | Open Energy Information  

Open Energy Info (EERE)

Power Power Jump to: navigation, search Name Clyde Light & Power Place Ohio Utility Id 3824 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png C1 - General Service - No Demand Commercial C1A - General Service No Demand - Three Phase Commercial C2 - Commercial Commercial FL - Flood Light Lighting G1- General Service w/ Demand Commercial LP1- Large Power Secondary Industrial LP2 - Primary Industrial R1 - Residential Residential

180

Carroll Electric Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Coop, Inc Coop, Inc Place Ohio Utility Id 3076 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Residential & Public Building Service Residential Residential & Public Building Service - Water Heater Control Switch Security Lights Lighting Security Lights with Pole and Transformer Lighting Security Lights with Transformer Lighting Security Lights(With Pole) Average Rates Residential: $0.1170/kWh Commercial: $0.1250/kWh Industrial: $0.1020/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Borough of Weatherly, Pennsylvania (Utility Company) | Open Energy  

Open Energy Info (EERE)

Weatherly, Pennsylvania (Utility Company) Weatherly, Pennsylvania (Utility Company) Jump to: navigation, search Name Borough of Weatherly Place Pennsylvania Utility Id 20232 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Large Power and Light Service Commercial Night Light- (175W) Lighting Primary Power and Light Service Commercial Residential Service Residential Small Power and Light Service Commercial Average Rates Residential: $0.1410/kWh Industrial: $0.1210/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

182

Indiana Michigan Power Co | Open Energy Information  

Open Energy Info (EERE)

Indiana Michigan Power Co Indiana Michigan Power Co Place Ohio Service Territory Indiana, Michigan Website www.indianamichiganpower. Green Button Reference Page www.aep.com/newsroom/news Green Button Committed Yes Utility Id 9324 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules

183

Claverack Rural Elec Coop Inc | Open Energy Information  

Open Energy Info (EERE)

Claverack Rural Elec Coop Inc Claverack Rural Elec Coop Inc Jump to: navigation, search Name Claverack Rural Elec Coop Inc Place Pennsylvania Utility Id 40289 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Service, Three-Phase Commercial Residential Service Residential Residential Service TOU Residential Average Rates Residential: $0.1280/kWh Commercial: $0.1370/kWh Industrial: $0.0902/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from

184

City of Seaford, Delaware (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Seaford, Delaware (Utility Company) Seaford, Delaware (Utility Company) Jump to: navigation, search Name City of Seaford Place Delaware Utility Id 16852 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png COMMERCIAL NON-DEMAND METERING Commercial COMMERCIAL WITH DEMAND METERING Commercial LARGE GENERAL SERVICE -PRIMARY ENERGY Industrial LARGE GENERAL SERVICE ENERGY Industrial MEDIUM GENERAL SERVICE Industrial RESIDENTIAL Residential SECURITY LIGHTS Lighting STREET CHARGE Commercial Average Rates Residential: $0.1580/kWh

185

Borough of Olyphant, Pennsylvania (Utility Company) | Open Energy  

Open Energy Info (EERE)

Olyphant, Pennsylvania (Utility Company) Olyphant, Pennsylvania (Utility Company) Jump to: navigation, search Name Borough of Olyphant Place Pennsylvania Utility Id 14124 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial and Small Industrial Rate Commercial Residential Rate Residential Average Rates Residential: $0.1860/kWh Commercial: $0.1880/kWh Industrial: $0.1980/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Borough_of_Olyphant,_Pennsylvania_(Utility_Company)&oldid=409098

186

City of Sturgis, Michigan (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Sturgis, Michigan (Utility Company) Sturgis, Michigan (Utility Company) Jump to: navigation, search Name City of Sturgis Place Michigan Utility Id 18252 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial & Industrial-Rate D Industrial Commerical & Industrial Commercial Commerical-All Electric Commercial General Service Commercial Large Primary Power Service Industrial

187

Metropolitan Edison Co | Open Energy Information  

Open Energy Info (EERE)

Metropolitan Edison Co Metropolitan Edison Co Jump to: navigation, search Name Metropolitan Edison Co Place Ohio Utility Id 12390 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png RS Residential RT (Time-Of-Day) Residential Average Rates No Rates Available The following table contains monthly sales and revenue data for

188

Dayton Power & Light Co | Open Energy Information  

Open Energy Info (EERE)

Dayton Power & Light Co Dayton Power & Light Co Jump to: navigation, search Name Dayton Power & Light Co Place Ohio Utility Id 4922 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png RS - D17 Residential Average Rates Residential: $0.0404/kWh Commercial: $0.0167/kWh

189

City of St Marys, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Marys, Ohio (Utility Company) Marys, Ohio (Utility Company) Jump to: navigation, search Name City of St Marys Place Ohio Utility Id 17891 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Retail Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial General Credit Interruptible Rate Commercial Commercial General Power Commercial Commercial General Power-Tax Exempt Commercial Commercial General Service Distribution 129 Commercial

190

Delmarva Power | Open Energy Information  

Open Energy Info (EERE)

(Redirected from DPL) (Redirected from DPL) Jump to: navigation, search Name Delmarva Power Place Delaware Service Territory Delaware, Maryland Website www.delmarva.com/home/ Green Button Committed Yes Utility Id 5027 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png "SGS-ND" & "MGS-S" SH (Bundled) Commercial

191

Southern Maryland Elec Coop Inc | Open Energy Information  

Open Energy Info (EERE)

Elec Coop Inc Elec Coop Inc (Redirected from SMECO) Jump to: navigation, search Name Southern Maryland Elec Coop Inc Place Maryland Utility Id 17637 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Calvert Cliffs Standby Service Industrial General Service Demand 3 Phase Commercial Commercial General Service Demand 3 Phase Industrial Industrial General Service Demand Commercial Commercial General Service Demand Industrial Industrial

192

Tri-County Rural Elec Coop Inc | Open Energy Information  

Open Energy Info (EERE)

Tri-County Rural Elec Coop Inc Tri-County Rural Elec Coop Inc Place Pennsylvania Utility Id 40290 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 3 Phase Demand Commercial 3 Phase Demand Tri-county Commercial CP1 Commercial CP3 Industrial ETS2D Commercial ETS2M Commercial ETSDM Commercial ETSTC Commercial LP2 Commercial LP3 Industrial NCP1 Residential Residential Residential 2C Residential Residential 3C Residential Residential 4C Residential Residential Tri-County Residential Seasonal Budget Commercial

193

Hagerstown Light Department | Open Energy Information  

Open Energy Info (EERE)

Hagerstown Light Department Hagerstown Light Department Jump to: navigation, search Name Hagerstown Light Department Place Maryland Utility Id 7908 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png GENERAL AND COMMERCIAL SERVICE Commercial LIGHT AND POWER SERVICE (HIGH LOAD FACTOR) Industrial LIGHT AND POWER SERVICE (Low Load Factor) Commercial OUTDOOR LIGHTING SERVICE (200 Watts)Fluorescent luminaire Lighting OUTDOOR LIGHTING SERVICE(100 Watts)Fluorescent luminaire Lighting OUTDOOR LIGHTING SERVICE(175 Watts MV)) Lighting

194

Borough of South River, New Jersey (Utility Company) | Open Energy  

Open Energy Info (EERE)

Jersey (Utility Company) Jersey (Utility Company) Jump to: navigation, search Name Borough of South River Place New Jersey Utility Id 17571 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Class A : Residential Consumption Residential Class B: General Service/Nondemand Consumption Commercial Class C: Retail Power/Demand Consumption Commercial Class F: Street Lighting Consumption Lighting Class F: Yard Lighting Lighting Class H: Standby Emergency Service Commercial Class I: Commercial Demand Rate Commercial

195

Borough of Kutztown, Pennsylvania (Utility Company) | Open Energy  

Open Energy Info (EERE)

Kutztown, Pennsylvania (Utility Company) Kutztown, Pennsylvania (Utility Company) Jump to: navigation, search Name Borough of Kutztown Place Pennsylvania Utility Id 10494 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png CUSTOMER GENERATED NET ELECTRICITY GENERAL INDUSTRIAL SERVICE Industrial GENERAL RESIDENTIAL SERVICE Residential INSTITIONAL SERVICE RATE 105000 Commercial INSTITIONAL SERVICE RATE 105000 NON ELECTRIC Commercial INSTITIONAL SERVICE RATE 120000 NON ELECTRIC Commercial

196

Guernsey-Muskingum El Coop Inc | Open Energy Information  

Open Energy Info (EERE)

Guernsey-Muskingum El Coop Inc Guernsey-Muskingum El Coop Inc Jump to: navigation, search Name Guernsey-Muskingum El Coop Inc Place Ohio Utility Id 7891 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Service Commercial Farm and Home Service Residential Seasonal Residential Service Residential Average Rates Residential: $0.1220/kWh Commercial: $0.1120/kWh Industrial: $0.0721/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Guernsey-Muskingum_El_Coop_Inc&oldid=410780"

197

Monongahela Power Co | Open Energy Information  

Open Energy Info (EERE)

Monongahela Power Co Monongahela Power Co Place Pennsylvania Utility Id 12796 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png A Residential B (General Service) Commercial C (General Service) Commercial D (General Service) Commercial Average Rates No Rates Available The following table contains monthly sales and revenue data for Monongahela

198

REA Energy Coop Inc | Open Energy Information  

Open Energy Info (EERE)

REA Energy Coop Inc REA Energy Coop Inc Jump to: navigation, search Name REA Energy Coop Inc Place Pennsylvania Utility Id 40292 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Service Commercial Electric Heat Residential Electric Heat Over 7000 Commercial Residential Service Residential Average Rates Residential: $0.1040/kWh Commercial: $0.0919/kWh Industrial: $0.0915/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=REA_Energy_Coop_Inc&oldid=411419"

199

Northeastern Rural E M C | Open Energy Information  

Open Energy Info (EERE)

Northeastern Rural E M C Northeastern Rural E M C Jump to: navigation, search Name Northeastern Rural E M C Place Indiana Utility Id 20603 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Outdoor Lighting Energy: Ballasted Lamps 1000W Lighting Outdoor Lighting Energy: Ballasted Lamps 100W Lighting Outdoor Lighting Energy: Ballasted Lamps 150W Lighting Outdoor Lighting Energy: Ballasted Lamps 175W Lighting Outdoor Lighting Energy: Ballasted Lamps 200W Lighting Outdoor Lighting Energy: Ballasted Lamps 250W Lighting

200

Easton Utilities Comm | Open Energy Information  

Open Energy Info (EERE)

Utilities Comm Utilities Comm Jump to: navigation, search Name Easton Utilities Comm Place Maryland Utility Id 5625 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png LARGE GENERAL SERVICE Commercial LARGE GENERAL SERVICE(Primary Metering) Commercial PRIMARY GENERAL SERVICE Commercial RESIDENTIAL RATE Residential SMALL GENERAL SERVICE Commercial SMALL GENERAL SERVICE(Primary Metering) Commercial

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

American Mun Power-Ohio, Inc | Open Energy Information  

Open Energy Info (EERE)

Power-Ohio, Inc Power-Ohio, Inc Jump to: navigation, search Name American Mun Power-Ohio, Inc Place Ohio Utility Id 40577 Utility Location Yes Ownership A NERC Location RFC NERC RFC Yes RTO PJM Yes ISO MISO Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=American_Mun_Power-Ohio,_Inc&oldid=408975"

202

Craig-Botetourt Electric Coop | Open Energy Information  

Open Energy Info (EERE)

Craig-Botetourt Electric Coop Craig-Botetourt Electric Coop Place Virginia Utility Id 4471 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png SCHEDULE CS-10-U Multi-Phase Commercial SCHEDULE CS-10-U Single Phase Commercial SCHEDULE CS-10-U-RA Multi-Phase Commercial SCHEDULE CS-10-U-RA Single Phase Commercial SCHEDULE CSTOU-1-U Multi-Phase Commercial SCHEDULE CSTOU-1-U Single Phase Commercial SCHEDULE GREEN-1-U Commercial SCHEDULE LP 10-U RA - Commercial Commercial SCHEDULE LP 10-U-RA - Industrial Industrial

203

Kentucky Power Co | Open Energy Information  

Open Energy Info (EERE)

Ohio Ohio Service Territory Kentucky Website www.kentuckypower.com Green Button Reference Page www.aep.com/newsroom/news Green Button Committed Yes Utility Id 22053 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png RS Residential

204

City of Dowagiac, Michigan (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Dowagiac, Michigan (Utility Company) Dowagiac, Michigan (Utility Company) Jump to: navigation, search Name City of Dowagiac Place Michigan Utility Id 5343 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png GENERAL SERVICE Commercial LARGE GENERAL SERVICE Commercial LARGE GENERAL SERVICE Discount Commercial MUNICIPAL WATER SERVICE Commercial PUBLIC SERVICES Commercial RESIDENTIAL ELECTRIC SERVICE Residential Average Rates Residential: $0.1160/kWh Commercial: $0.1220/kWh Industrial: $0.0870/kWh References

205

Village of New Bremen, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Bremen Bremen Place Ohio Utility Id 13420 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Commercial Commercial - Rural Commercial Commercial - Three Phase Commercial Commercial Demand Service Commercial Governmental Service Commercial Governmental Service - Three Phase Commercial Large Power Service Industrial Outdoor Light Service - 175 Watt Lighting Outdoor Light Service - 250 Watt Lighting Outdoor Light Service - 400 Watt Lighting Residential Commercial Residential - Rural Commercial

206

PECO Energy Co | Open Energy Information  

Open Energy Info (EERE)

PECO) PECO) Jump to: navigation, search Name PECO Energy Co Place Philadelphia, Pennsylvania Service Territory Pennsylvania Website www.peco.com/Pages/Home.a Green Button Reference Page www.peco.com/News/NewsRel Green Button Committed Yes Utility Id 14940 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] SGIC[3] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. PECO Energy Company Smart Grid Project was awarded $200,000,000 Recovery

207

Village of Republic, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Ohio (Utility Company) Ohio (Utility Company) Jump to: navigation, search Name Village of Republic Place Ohio Utility Id 15865 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Commercial Residential Residential Three Phase Commercial Average Rates Residential: $0.1250/kWh Commercial: $0.1350/kWh Industrial: $0.1910/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Village_of_Republic,_Ohio_(Utility_Company)&oldid=412064

208

Atlantic City Electric Co | Open Energy Information  

Open Energy Info (EERE)

Atlantic City Electric Co Atlantic City Electric Co Place Mays Landing, New Jersey Service Territory New Jersey Website www.atlanticcityelectric. Green Button Committed Yes Utility Id 963 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] SGIC[3] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! Atlantic City Electric Company Smart Grid Project was awarded $18,700,000 Recovery Act Funding with a total project value of $37,400,000.

209

City of Richmond, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Richmond, Indiana (Utility Company) Richmond, Indiana (Utility Company) Jump to: navigation, search Name City of Richmond Place Indiana Utility Id 15989 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Cogeneration Industrial Commercial Lighting Lighting Electric Heating Schools Commercial General Electric Heating Commercial General Power Commercial Industrial Service Industrial

210

City of Westerville, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

(Redirected from City of Westerville, OH) (Redirected from City of Westerville, OH) Jump to: navigation, search Name City of Westerville Place Westerville, Ohio Utility Id 20477 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] SGIC[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. City of Westerville, OH Smart Grid Project was awarded $4,320,000 Recovery Act Funding with a total project value of $10,663,000. Utility Rate Schedules Grid-background.png 175 watt mercury vapor light/100 watt high pressure sodium light(pole in place) Lighting 175 watt mercury vapor light/100 watt high pressure sodium light(city

211

City of Galion, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Galion Galion Place Ohio Utility Id 6914 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Account Commercial Large Power Account Industrial Large Power Account- Own Transformer Industrial Power Account Commercial Residential Account Residential Security Light- 175 W Lighting Security Light- 400 W Lighting Average Rates Residential: $0.0967/kWh Commercial: $0.0831/kWh Industrial: $0.0723/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

212

West Penn Power Co | Open Energy Information  

Open Energy Info (EERE)

West Penn Power Co West Penn Power Co Place Pennsylvania Utility Id 20387 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 10 (Residential Service) Residential 20 (General Service) Commercial 30 (General Power Service >500kW) Commercial 30 (General Power Service 100kW-500kW) Commercial Average Rates Residential: $0.0291/kWh Commercial: $0.0110/kWh Industrial: $0.0058/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

213

City of Mishawaka, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Indiana (Utility Company) Indiana (Utility Company) Jump to: navigation, search Name City of Mishawaka Place Indiana Utility Id 12674 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Buying Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Power Service Commercial Commerical(10kW or more) Commercial Commerical(less than 10kW) Commercial Electric Heating Commercial Municipal Electric Service Commercial Outdoor lighting- 1,000 watt mercury vapor lamp Lighting Outdoor lighting- 100 watt sodium lamp Lighting Outdoor lighting- 175 watt mercury vapor lamp Lighting

214

Sullivan County R E C, Inc | Open Energy Information  

Open Energy Info (EERE)

Sullivan County R E C, Inc Sullivan County R E C, Inc Jump to: navigation, search Name Sullivan County R E C, Inc Place Pennsylvania Utility Id 40291 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Alternative Energy Production Rate Annual Electric Thermal Storage/Dual Fuel Service Commercial Annual Eletric Service Commercial Annual Small General Service Commercial Electric Thermal Storage/Dual Fuel Service Commercial Large General Service Industrial Large General Service Curtailment Service Industrial

215

Paulding-Putman Elec Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Paulding-Putman Elec Coop, Inc Paulding-Putman Elec Coop, Inc Place Ohio Utility Id 14599 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Generator Station Service Industrial Power Service-1 Industrial Industrial Service Power 2 Industrial Large Power Off Peak Service Industrial Large Power Service Industrial Large Power Stand-by Service Industrial Municipal Streert Lights 100 W Lighting Outdoor & Street Light 100 W (Energy Only-Unmetered, Owned and Maintained by Member) Lighting Outdoor & Street Light 175 W (Energy Only-Unmetered; Owned and Maintained

216

PECO Energy Co | Open Energy Information  

Open Energy Info (EERE)

PECO Energy Co PECO Energy Co Place Philadelphia, Pennsylvania Service Territory Pennsylvania Website www.peco.com/Pages/Home.a Green Button Reference Page www.peco.com/News/NewsRel Green Button Committed Yes Utility Id 14940 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] SGIC[3] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. PECO Energy Company Smart Grid Project was awarded $200,000,000 Recovery Act Funding with a total project value of $415,118,677.

217

Choptank Electric Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Choptank Electric Coop, Inc Choptank Electric Coop, Inc Jump to: navigation, search Name Choptank Electric Coop, Inc Place Maryland Utility Id 3503 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Commercial General Service - Medium Industrial General Service - Small Industrial LIGHTING SERVICE - HPS 100W Lighting LIGHTING SERVICE - HPS 150W Lighting LIGHTING SERVICE - HPS 250W Lighting LIGHTING SERVICE - HPS 400W Lighting LIGHTING SERVICE - HPS 70W Lighting LIGHTING SERVICE - MV 100W Lighting

218

Delmarva Power | Open Energy Information  

Open Energy Info (EERE)

Delmarva Power Delmarva Power Place Delaware Service Territory Delaware, Maryland Website www.delmarva.com/home/ Green Button Committed Yes Utility Id 5027 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png "SGS-ND" & "MGS-S" SH (Bundled) Commercial

219

Southern Maryland Elec Coop Inc | Open Energy Information  

Open Energy Info (EERE)

Elec Coop Inc Elec Coop Inc Jump to: navigation, search Name Southern Maryland Elec Coop Inc Place Maryland Utility Id 17637 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Calvert Cliffs Standby Service Industrial General Service Demand 3 Phase Commercial Commercial General Service Demand 3 Phase Industrial Industrial General Service Demand Commercial Commercial General Service Demand Industrial Industrial General Service Demand Primary Commercial Commercial

220

Frontier Power Company | Open Energy Information  

Open Energy Info (EERE)

Power Company Power Company Place Ohio Utility Id 6804 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial And Industrial Lighting And Power Service Commercial Large Power Service Residential Sales,Residential Sales Seasonal And Public Building Service Residential Average Rates Residential: $0.1160/kWh Commercial: $0.1180/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Frontier_Power_Company&oldid=410728"

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Bedford Rural Elec Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Bedford Rural Elec Coop, Inc Bedford Rural Elec Coop, Inc Place Pennsylvania Utility Id 40221 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Commercial Commercial Large Commercial Interruptible Commercial Large Commercial Power Commercial Off Peak Rider for DUFEL Commercial Off Peak Rider for ETSTR Commercial Outdoor lighting 1000w HPS Lighting Outdoor lighting 1000w Mercury Vapor Lighting Outdoor lighting 100w HPS Lighting Outdoor lighting 175w Mercury Vapor Lighting Outdoor lighting 250w HPS Lighting

222

Borough of New Wilmington, Pennsylvania (Utility Company) | Open Energy  

Open Energy Info (EERE)

New Wilmington New Wilmington Place Pennsylvania Utility Id 13489 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Service Commercial Large General Service Commercial Residential Service Residential Small General Service Commercial Average Rates Residential: $0.1400/kWh Commercial: $0.1260/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Borough_of_New_Wilmington,_Pennsylvania_(Utility_Company)&oldid=40909

223

Adams Electric Cooperative Inc | Open Energy Information  

Open Energy Info (EERE)

Cooperative Inc Cooperative Inc Jump to: navigation, search Name Adams Electric Cooperative Inc Place Pennsylvania Utility Id 40220 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png DGE 18 Residential DGW40 Commercial Dual fuel/geothermal (DFG10) Commercial RHW32 Commercial RSW31 Commercial Rate Schedule A-1 Residential Rate Schedule A-3 Residential Rate Schedule L (FL1) Commercial Rate Schedule L (FL2) Commercial Rate Schedule L (HPP) Commercial

224

Town of Berlin, Maryland (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Town of Town of Place Maryland Utility Id 1615 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Classification #1 Residential Service Residential Classification #2 Commercial-Non Demand Commercial Classification #3 General Service Commercial Commercial Classification #3 General Service Industrial Industrial Classification #4 Primary Service Commercial Commercial

225

Borough of Quakertown, Pennsylvania (Utility Company) | Open Energy  

Open Energy Info (EERE)

Quakertown, Pennsylvania (Utility Company) Quakertown, Pennsylvania (Utility Company) Jump to: navigation, search Name Borough of Quakertown Place Pennsylvania Utility Id 15541 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial All Electric (Electric Heat) Commercial Commercial All Electric (Electric Heat) V2 Commercial Commercial General Electric Commercial Commercial General Electric V2 Commercial Industrial service rate (1) Industrial Industrial service rate (2) Industrial

226

A & N Electric Coop (Virginia) | Open Energy Information  

Open Energy Info (EERE)

Coop (Virginia) Coop (Virginia) Jump to: navigation, search Name A & N Electric Coop Place Virginia Utility Id 84 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1]Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Service - Retail Access - Schedule B-U-RA Multi-Phase Commercial Commercial Service - Retail Access - Schedule B-U-RA Single Phase Commercial Commercial Service - Schedule B-U Single Phase Commercial

227

Somerset Rural Elec Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Somerset Rural Elec Coop, Inc Somerset Rural Elec Coop, Inc Jump to: navigation, search Name Somerset Rural Elec Coop, Inc Place Pennsylvania Utility Id 40167 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt Lamp(Mercury Vapor) Lighting 175 Watt Lamp(Mercury Vapor) Lighting 400 Watt Lamp(Mercury Vapor) Lighting Commercial Service Single-Phase Commercial Dairy Farm Water Heating-Schedule DF Commercial Electric Thermal Storage and Dual Fuel, Schedule EM Commercial Farm and Home Service-Space Heating Residential

228

City of Westerville, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search Jump to: navigation, search Name City of Westerville Place Westerville, Ohio Utility Id 20477 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] SGIC[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. City of Westerville, OH Smart Grid Project was awarded $4,320,000 Recovery Act Funding with a total project value of $10,663,000. Utility Rate Schedules Grid-background.png 175 watt mercury vapor light/100 watt high pressure sodium light(pole in place) Lighting 175 watt mercury vapor light/100 watt high pressure sodium light(city

229

Commonwealth Edison Co | Open Energy Information  

Open Energy Info (EERE)

Commonwealth Edison Co Commonwealth Edison Co (Redirected from ComED) Jump to: navigation, search Name Commonwealth Edison Co Place Illinois Service Territory Illinois Website www.comed.com/Pages/defau Green Button Landing Page www.comed.com/Pages/defau Green Button Reference Page www.whitehouse.gov/admini Green Button Implemented Yes Utility Id 4110 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it.

230

Wheeling Power Co | Open Energy Information  

Open Energy Info (EERE)

Wheeling Power Co Wheeling Power Co Place Ohio Service Territory West Virginia Website www.aepohio.com Green Button Reference Page www.aep.com/newsroom/news Green Button Committed Yes Utility Id 20521 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available The following table contains monthly sales and revenue data for Wheeling

231

Village of Jackson Center, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Jackson Center Jackson Center Place Ohio Utility Id 9572 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Service- Single-Phase Commercial General Service- Three-Phase Commercial General Service-Demand- Single-Phase Commercial General Service-Demand- Three-Phase Commercial Large Power Service- Primary Metering Industrial Large Power Service- Secondary Metering Industrial Residential Service Residential Average Rates Residential: $0.1050/kWh

232

Village of Winnetka, Illinois (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Winnetka, Illinois (Utility Company) Winnetka, Illinois (Utility Company) Jump to: navigation, search Name Winnetka Village of Place Illinois Utility Id 20824 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Distribution Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Rate 1- Residential: Single Phase Residential Rate 1- Residential: Three Phase Residential Rate 18- Street Lights Lighting Rate 2- Space Heating Customers: Single Phase

233

Virginia Tech Electric Service | Open Energy Information  

Open Energy Info (EERE)

Electric Service Electric Service Jump to: navigation, search Name Virginia Tech Electric Service Place Virginia Utility Id 19882 Utility Location Yes Ownership S NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Large General Industrial Medium General Commercial Residential Residential Sanctuary Commercial Small General Commercial Average Rates Residential: $0.0971/kWh Commercial: $0.0832/kWh Industrial: $0.0765/kWh The following table contains monthly sales and revenue data for Virginia

234

Village of Beach City, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

City City Place Ohio Utility Id 1386 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png All Electric-In Commercial All Electric-Out Commercial Commercial Commercial Industrial Industrial RESIDENTlAL-IN Residential RESIDENTlAL-OUT Residential Sewer Plant Commercial Average Rates Residential: $0.0906/kWh Commercial: $0.0885/kWh Industrial: $0.0876/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from

235

City of Radford, Virginia (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Radford, Virginia (Utility Company) Radford, Virginia (Utility Company) Jump to: navigation, search Name City of Radford Place Virginia Utility Id 15619 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Large General Service Industrial Large Power Service Industrial Medium General Service Commercial Outdoor Lighting (per month) 100 watt sodium vapor - 15,000 lumens Lighting

236

Town of Avilla, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Avilla, Indiana (Utility Company) Avilla, Indiana (Utility Company) Jump to: navigation, search Name Town of Avilla Place Indiana Utility Id 1028 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Rate LGS1: Large General Service, Secondary Industrial Rate LMS: Large Municipal Service Commercial Rate P1: Electric Power Service, Secondary Industrial Rate RS Residential Rate S: School Service Commercial Rate SGS: Small General Service Commercial Rate SMS: Small Municipal Service Commercial

237

Jersey Central Power & Lt Co | Open Energy Information  

Open Energy Info (EERE)

(Redirected from JCP&L) (Redirected from JCP&L) Jump to: navigation, search Name Jersey Central Power & Lt Co Place Ohio Utility Id 9726 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png GS (General Service) Commercial GST (General Service Time-Of-Day) Commercial

238

Sussex Rural Electric Coop Inc | Open Energy Information  

Open Energy Info (EERE)

Sussex Rural Electric Coop Inc Sussex Rural Electric Coop Inc Jump to: navigation, search Name Sussex Rural Electric Coop Inc Place New Jersey Utility Id 40299 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Service ETS Commercial Large Power Service LP Commercial Residential Service(New Jersey) Residential Residential Service(New York) Residential Average Rates Residential: $0.1190/kWh Commercial: $0.1150/kWh Industrial: $0.0890/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

239

Valley Rural Electric Coop Inc | Open Energy Information  

Open Energy Info (EERE)

Valley Rural Electric Coop Inc Valley Rural Electric Coop Inc Place Pennsylvania Utility Id 40222 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Area Lights 100w HPS Lighting Area Lights 100w Mercury Vapor Lighting Area Lights 150w HPS Lighting Area Lights 175w Mercury Vapor Lighting Area Lights 250w HPS Lighting Area Lights 250w Mercury Vapor Lighting Area Lights 400w HPS Lighting Area Lights 400w Mercury Vapor Lighting Residential Residential Average Rates Residential: $0.1080/kWh Commercial: $0.1020/kWh

240

Village of Cygnet, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Cygnet, Ohio (Utility Company) Cygnet, Ohio (Utility Company) Jump to: navigation, search Name Village of Cygnet Place Ohio Utility Id 4685 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Service Commercial Large Power Industrial Residential Residential Average Rates Residential: $0.1050/kWh Commercial: $0.1080/kWh Industrial: $0.1890/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Village_of_Cygnet,_Ohio_(Utility_Company)&oldid=411974

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

City of Dover, Delaware (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Dover, Delaware (Utility Company) Dover, Delaware (Utility Company) Jump to: navigation, search Name Dover City of Place Delaware Utility Id 5335 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Private Outdoor Lighting: Decorative Lighting, Metered, 150 watt HPS w/o ladder rest Lighting Private Outdoor Lighting: Decorative Lighting, Metered, 70 watt HPS w/o ladder rest Lighting Private Outdoor Lighting: Decorative Lighting, Unmetered, 150 watt HPS w/o

242

City of Columbiana, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Ohio (Utility Company) Ohio (Utility Company) Jump to: navigation, search Name Columbiana City of Place Ohio Utility Id 4061 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Rates Commercial Heavy Commercial-Industrial Rates Commercial Municipal Water and Sewer Plant rates Residential Rental Lights (1000 Watt Metal Halide Light) Commercial Rental Lights (175 Watt Mercury Light) Commercial Rental Lights (250 Watt HPS Light) Commercial Rental Lights (400 Watt HPS Light) Commercial

243

Appalachian Power Co | Open Energy Information  

Open Energy Info (EERE)

APCO) APCO) Jump to: navigation, search Name Appalachian Power Co Abbreviation APCO Affiliate Of AEP Place Ohio Service Territory Virginia, West Virginia, Tennessee Website www.appalachianpower.com Green Button Reference Page www.aep.com/newsroom/news Green Button Committed Yes Utility Id 733 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Buying Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now!

244

City of Garrett, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Garrett, Indiana (Utility Company) Garrett, Indiana (Utility Company) Jump to: navigation, search Name City of Garrett Place Indiana Utility Id 6970 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Commercial Municipal Service Commercial Power Service Industrial Residential Residential Security Lighting Lighting Average Rates Residential: $0.0837/kWh Commercial: $0.0852/kWh Industrial: $0.0785/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from

245

Borough of Mifflinburg, Pennsylvania (Utility Company) | Open Energy  

Open Energy Info (EERE)

Mifflinburg, Pennsylvania (Utility Company) Mifflinburg, Pennsylvania (Utility Company) Jump to: navigation, search Name Borough of Mifflinburg Place Pennsylvania Utility Id 12523 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Light and Power Secondary Service- GLP-4 Commercial General Light and Power Secondary Service- 1 kW Minimum Commercial General Light and Power Secondary Service- 25 kW Minimum Commercial Residential Service Residential Average Rates Residential: $0.1380/kWh Commercial: $0.1660/kWh

246

Potomac Electric Power Co | Open Energy Information  

Open Energy Info (EERE)

Potomac Electric Power Co Potomac Electric Power Co Place District of Columbia Service Territory District of Columbia, Maryland Website www.pepco.com/home/ Green Button Landing Page www.pepco.com/home/billin Green Button Reference Page www.pepcoholdings.com/abo Green Button Implemented Yes Utility Id 15270 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] SGIC[3] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it.

247

Village of Bloomdale, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Bloomdale Bloomdale Place Ohio Utility Id 1677 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial (Single Phase- With Demand) Commercial Commercial (Single Phase-without demand) Commercial Commercial (Three Phase- With Demand) Commercial Large Power (LP) Rate Commercial Residential Rate Residential Average Rates Residential: $0.1060/kWh Commercial: $0.1090/kWh Industrial: $0.1410/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

248

PEPCO Energy Services | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search Jump to: navigation, search Name PEPCO Energy Services Place Virginia Utility Id 14405 Utility Location Yes Ownership R NERC Location RFC NERC ERCOT Yes NERC RFC Yes ISO Ercot Yes RTO PJM Yes ISO NY Yes ISO NE Yes Activity Retail Marketing Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png R Residential RTM Residential Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=PEPCO_Energy_Services&oldid=411295"

249

PPL Electric Utilities Corp | Open Energy Information  

Open Energy Info (EERE)

PPL Electric Utilities Corp PPL Electric Utilities Corp Jump to: navigation, search Name PPL Electric Utilities Corp Place Allentown, Pennsylvania Service Territory Pennsylvania Website www.pplelectric.com Green Button Reference Page pplweb.mediaroom.com/inde Green Button Committed Yes Utility Id 14715 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] SGIC[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. PPL Electric Utilities Corp. Smart Grid Project was awarded $19,054,516 Recovery Act Funding with a total project value of $38,109,032.

250

Wabash Valley Power Assn, Inc | Open Energy Information  

Open Energy Info (EERE)

Wabash Valley Power Assn, Inc Wabash Valley Power Assn, Inc Place Indiana Utility Id 40211 Utility Location Yes Ownership C NERC Location RFC,SERC NERC RFC Yes RTO PJM Yes ISO MISO Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Wabash_Valley_Power_Assn,_Inc&oldid=412136

251

City of Anderson, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Anderson, Indiana (Utility Company) Anderson, Indiana (Utility Company) Jump to: navigation, search Name City of Anderson Place Indiana Utility Id 636 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Constant Load Commercial Constant Load- Industrial Industrial General Service- Single Phase Commercial General Service- Single Phase- Industrial Industrial General Service- Three Phase Commercial General Service- Three Phase- Industrial Industrial Large Power Commercial Large Power Industrial (Equipment Supplied by Customer) Industrial

252

Appalachian Power Co | Open Energy Information  

Open Energy Info (EERE)

Power Co Power Co Abbreviation APCO Affiliate Of AEP Place Ohio Service Territory Virginia, West Virginia, Tennessee Website www.appalachianpower.com Green Button Reference Page www.aep.com/newsroom/news Green Button Committed Yes Utility Id 733 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Buying Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it.

253

Kingsport Power Co | Open Energy Information  

Open Energy Info (EERE)

Kingsport Power Co Kingsport Power Co Place Ohio Service Territory Tennessee Website www.appalachianpower.com Green Button Reference Page www.aep.com/newsroom/news Green Button Committed Yes Utility Id 10331 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available The following table contains monthly sales and revenue data for Kingsport

254

Atlantic City Electric Co | Open Energy Information  

Open Energy Info (EERE)

Co Co (Redirected from Atlantic City Electric Company) Jump to: navigation, search Name Atlantic City Electric Co Place Mays Landing, New Jersey Service Territory New Jersey Website www.atlanticcityelectric. Green Button Committed Yes Utility Id 963 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] SGIC[3] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! Atlantic City Electric Company Smart Grid Project was awarded $18,700,000

255

City of Gas City, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

City, Indiana (Utility Company) City, Indiana (Utility Company) Jump to: navigation, search Name City of Gas City Place Indiana Utility Id 6993 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png All Electric Heat for Library or School Service Commercial Commercial and General Power Service Commercial Outdoor Lighting- 1000 W Lighting Outdoor Lighting- 175 W Lighting Outdoor Lighting- 400 W Lighting Public Street Lighting and Highway Lighting- 175 W Mercury Vapor/100 W HPS Lighting Public Street Lighting and Highway Lighting-400 W Mercury Vapor/250 W HPS

256

City of Niles, Michigan (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Niles Niles Place Michigan Utility Id 13604 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png DOMESTIC USE - IN CITY Residential DOMESTIC USE - OUT OF CITY Residential DUSK TO DAWN OUTDOOR LIGHTING (1000 watt) Lighting DUSK TO DAWN OUTDOOR LIGHTING (175 watt) Lighting DUSK TO DAWN OUTDOOR LIGHTING (400 watt) Lighting GENERAL SERVICE -IN CITY AND OUT OF CITY Less than 25 kW Commercial GENERAL SERVICE 1 - CITY AND NON-CITY More than 25 kW Commercial MEDIUM INDUSTRIAL POWER(Distribution Voltage) Industrial

257

Union Rural Electric Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Rural Electric Coop, Inc Rural Electric Coop, Inc Place Ohio Utility Id 19501 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Single Phase Commercial Commercial Three Phase General Service (0-99 KVA) Commercial Commercial Three Phase General Service (100-299 KVA) Commercial Commercial Three Phase General Service (300-749 KVA) Commercial Commercial Three Phase General Service (750-1499 KVA) Commercial Single Phase Service Residential

258

Northwestern Rural E C A, Inc | Open Energy Information  

Open Energy Info (EERE)

Rural E C A, Inc Rural E C A, Inc Jump to: navigation, search Name Northwestern Rural E C A, Inc Place Pennsylvania Utility Id 40293 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Comfort Plus Rider - Residential Residential GZP - Growth Zone Pricing Service (Commercial) Commercial GZP - Growth Zone Pricing Service (Industrial) Industrial Heat Shift Rider Controlled 20 kW to 40 kW Residential Heat Shift Rider Controlled less than 20 kW - Residential Residential OFFP 3 - Interruptible / Off - Peak Space Heating Residential

259

Firelands Electric Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Firelands Electric Coop, Inc Firelands Electric Coop, Inc Jump to: navigation, search Name Firelands Electric Coop, Inc Place Ohio Utility Id 6335 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Service Single Phase Residential INTERRUPTABLE ELECTRIC GRAIN DRYING-(recent) Single Phase Commercial INTERRUPTABLE ELECTRIC GRAIN DRYING-(recent) Three Phase Commercial INTERRUPTABLE ELECTRIC GRAIN DRYING-Single Phase Commercial INTERRUPTABLE ELECTRIC GRAIN DRYING-Three Phase Commercial

260

South Central Power Company | Open Energy Information  

Open Energy Info (EERE)

Central Power Company Central Power Company Place Ohio Utility Id 18085 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Schedule GS General Service Schedule LP Large Power Service Schedule R Residential Service Residential Average Rates Residential: $0.1020/kWh Commercial: $0.0973/kWh Industrial: $0.0749/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=South_Central_Power_Company&oldid=411543

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

City of Orrville, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Orrville, Ohio (Utility Company) Orrville, Ohio (Utility Company) Jump to: navigation, search Name City of Orrville Place Ohio Utility Id 14194 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt High Pressure Sodium Lamp Metered Lighting 100 Watt High Pressure Sodium Lamp Unmetered Lighting 150 Watt High Pressure Sodium Lamp Metered Lighting

262

Indiana Municipal Power Agency | Open Energy Information  

Open Energy Info (EERE)

Municipal Power Agency Municipal Power Agency Place Indiana Utility Id 9234 Utility Location Yes Ownership A NERC Location RFC NERC RFC Yes RTO PJM Yes ISO MISO Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Indiana_Municipal_Power_Agency&oldid=41086

263

Columbus Southern Power Co | Open Energy Information  

Open Energy Info (EERE)

Power Co Power Co Jump to: navigation, search Name Columbus Southern Power Co Place Ohio Website www.aepohio.com Utility Id 4062 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Cogeneration and/or Small Power Production -T.O.D-Polyphase Commercial

264

City of New Martinsville, West Virginia (Utility Company) | Open Energy  

Open Energy Info (EERE)

West Virginia (Utility Company) West Virginia (Utility Company) Jump to: navigation, search Name New Martinsville City of Place West Virginia Utility Id 13471 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Large Power Commercial Large Power(Primary Metering) Commercial Residential Residential Security Light- 150W High Pressure Sodium Lighting Security Light- 175W Mercury Vapor Lighting Security Light- 250W High Pressure Sodium Lighting Security Light- 400W High Pressure Sodium Lighting Security Light- 400W Mercury Vapor Lighting

265

PECO Energy Co | Open Energy Information  

Open Energy Info (EERE)

Company) Company) Jump to: navigation, search Name PECO Energy Co Place Philadelphia, Pennsylvania Service Territory Pennsylvania Website www.peco.com/Pages/Home.a Green Button Reference Page www.peco.com/News/NewsRel Green Button Committed Yes Utility Id 14940 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] SGIC[3] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. PECO Energy Company Smart Grid Project was awarded $200,000,000 Recovery

266

Jersey Central Power & Lt Co | Open Energy Information  

Open Energy Info (EERE)

Place Ohio Place Ohio Utility Id 9726 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png GS (General Service) Commercial GST (General Service Time-Of-Day) Commercial RS Residential RT Residential Average Rates No Rates Available The following table contains monthly sales and revenue data for Jersey

267

Atlantic City Electric Co | Open Energy Information  

Open Energy Info (EERE)

Co Co (Redirected from ACE) Jump to: navigation, search Name Atlantic City Electric Co Place Mays Landing, New Jersey Service Territory New Jersey Website www.atlanticcityelectric. Green Button Committed Yes Utility Id 963 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Activity Bundled Services Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] SGIC[3] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! Atlantic City Electric Company Smart Grid Project was awarded $18,700,000

268

www.leeds.ac.uk/safety safety@leeds.ac.uk T:0113 34 34201 How can Health and Safety Services help you  

E-Print Network [OSTI]

www.leeds.ac.uk/safety safety@leeds.ac.uk T:0113 34 34201 How can Health and Safety Services help you: Health and Safety Services work in partnership with staff and the trade unions to help minimise with independent expertise and impartial advice. Each faculty/service group has an assigned Health and Safety

Haase, Markus

269

DE-AC05-06OR23100  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Section B - Page 1 of 10 Section B - Page 1 of 10 PART I - THE SCHEDULE SECTION B SUPPLIES OR SERVICES AND PRICES/COSTS B.1 ITEMS BEING ACQUIRED (ALTERNATE I) (OCT 2004) ................................... 3 B.2 ESTIMATED COST, BASE FEE, AND AWARD FEE (NOV 2004) ...................... 3 B.3 OPTION TO EXTEND THE CONTRACT (NOV 2004) .......................................... 6 B.4 OBLIGATION OF FUNDS (CPAF) (NOV 2004) ...................................................... 8 B.5 DETERMINATION OF AWARD FEE EARNED (NOV 2004) .............................. 9 DE-AC05-06OR23100 Section B - Page 2 of 10 Blank Page DE-AC05-06OR23100 Section B - Page 3 of 10 PART I - THE SCHEDULE SECTION B SUPPLIES OR SERVICES AND PRICES/COSTS B.1 ITEMS BEING ACQUIRED (ALTERNATE I) (OCT 2004)

270

SNL software manual for the ACS Data Analytics Project.  

SciTech Connect (OSTI)

In the ACS Data Analytics Project (also known as 'YumYum'), a supercomputer is modeled as a graph of components and dependencies, jobs and faults are simulated, and component fault rates are estimated using the graph structure and job pass/fail outcomes. This report documents the successful completion of all SNL deliverables and tasks, describes the software written by SNL for the project, and presents the data it generates. Readers should understand what the software tools are, how they fit together, and how to use them to reproduce the presented data and additional experiments as desired. The SNL YumYum tools provide the novel simulation and inference capabilities desired by ACS. SNL also developed and implemented a new algorithm, which provides faster estimates, at finer component granularity, on arbitrary directed acyclic graphs.

Stearley, Jon R.; McLendon, William Clarence, III; Rodrigues, Arun F.; Williams, Aaron S.; Hooper, Russell Warren; Robinson, David Gerald; Stickland, Michael G.

2011-10-01T23:59:59.000Z

271

AVTA: Aerovironment AC Level 2 Charging System Testing Results  

Broader source: Energy.gov [DOE]

The Vehicle Technologies Office's Advanced Vehicle Testing Activity carries out testing on a wide range of advanced vehicles and technologies on dynamometers, closed test tracks, and on-the-road. These results provide benchmark data that researchers can use to develop technology models and guide future research and development. The following report describes results from testing done on the Aerovironment AC Level 2 charging system for plug-in electric vehicles. This research was conducted by Idaho National Laboratory.

272

Analysis and interpretation of ac impedance data for porous electrodes  

SciTech Connect (OSTI)

Ac impedance spectroscopy has been used to measure the dynamic response of two types of porous gas-diffusion oxygen electrodes in a sulfuric acid electrolyte. Models were developed based on flooded and on thin-film pore structure. The transfer functions of these structures were calculated and the impedance result fitted to the models using a nonlinear least squares program. The results were used to assess the adequacies of the models.

Springer, T.E.; Raistrick, I.D.

1987-01-01T23:59:59.000Z

273

AVTA: Clipper Creek AC Level 2 Charging System Testing Results  

Broader source: Energy.gov [DOE]

The Vehicle Technologies Office's Advanced Vehicle Testing Activity carries out testing on a wide range of advanced vehicles and technologies on dynamometers, closed test tracks, and on-the-road. These results provide benchmark data that researchers can use to develop technology models and guide future research and development. The following report describes results from testing done on the ClipperCreek AC Level 2 charging system for plug-in electric vehicles. This research was conducted by Idaho National Laboratory.

274

AVTA: Eaton AC Level 2 Charging System Testing Results  

Broader source: Energy.gov [DOE]

The Vehicle Technologies Office's Advanced Vehicle Testing Activity carries out testing on a wide range of advanced vehicles and technologies on dynamometers, closed test tracks, and on-the-road. These results provide benchmark data that researchers can use to develop technology models and guide future research and development. The following report describes results from testing done on the Eaton AC Level 2 charging system for plug-in electric vehicles. This research was conducted by Idaho National Laboratory.

275

Variable Frequency AC Drives for Cooling Tower Energy Efficiency  

E-Print Network [OSTI]

and economics. Automatic fan speed control by sensing cold water temperature is the economic essence of the application of adjustable frequency power to A-C fan motors. 2.2 Cell Partitions In some multi-cell mechanical-draft cooling towers, the isolation... of individual cell air streams is ineffective due to one or more of the following: --Partitions are missing. --Partitions are incomplete. This condition results in temperature control problems. For example, if constant CWT is desired, and no means...

Corey, R. W.

1982-01-01T23:59:59.000Z

276

AC electrokinetic manipulation of selenium nanoparticles for potential nanosensor applications  

SciTech Connect (OSTI)

Highlights: ? Se nanoparticles were synthesized using a reverse-microemulsion process. ? AC osmotic fluid flow repulses the particles from electrode edges. ? Dielectrophoretic force attracts the particles to electrode edges. ? Dielectrophoresis electrode showed non-ohmic behavior. ? The device can potentially be used as a nanosensor. - Abstract: We report the AC electrokinetic behavior of selenium (Se) nanoparticles for electrical characterization and possible application as micro/nano devices. selenium Se nanoparticles were successfully synthesized using a reverse-microemulsion process and investigated structurally using X-ray diffraction and transmission electron microscope. Interdigitated castellated ITO and non-castellated platinum electrodes were employed for manipulation of suspended materials in the fluid. Using ITO electrodes at low frequency limits resulted in deposition of Se particles on electrode surface. When Se particles exposed to platinum electrodes in the 10 Hz1 kHz range and V {sub p?p}> 8, AC osmotic fluid flow repulses the particles from electrode edges. However, in 10 kHz10 MHz range and V {sub p?p}> 5, dielectrophoretic force attracts the particles to electrode edges. As the Se particle concentration increased, the trapped Se particles were aligned along the electric field line and bridged the electrode gap. The device was characterized and can potentially be useful in making micro/nano electronic devices.

Mahmoodi, Seyed Reza [School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Bayati, Marzieh, E-mail: m-bayati@tums.ac.ir [School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Hosseinirad, Somayeh [School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Foroumadi, Alireza [Department of Medicinal Chemistry, Faculty of Pharmacy and Pharmaceutical Sciences Research Center, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Gilani, Kambiz [Department of Pharmaceutics, School of Pharmacy, Tehran University of Medical Science, Tehran (Iran, Islamic Republic of); Rezayat, Seyed Mahdi [School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

2013-03-15T23:59:59.000Z

277

6 - Control systems for AC variable speed drives  

Science Journals Connector (OSTI)

Publisher Summary This chapter explores the control system, embodied in the control circuits. The simplest method of providing auxiliary power to the converter control circuits is from an auxiliary transformer connected to the mains. The primary need for current feedback in general purpose variable speed drives (VSDs) is inverter switching device protection. Various disadvantages of the vector controlled AC drive as compared to a DC drive are discussed in the chapter. The strategy of an AC vector control drive is to calculate the individual current vectors to eventually enable separate control of the flux current and the torque current under all speed and load conditions. The power circuit for a vector converter is almost identical to that used by a variable voltage variable frequency (VVVF) drive. High accuracy motor current feedback is also necessary to provide control of motor torque. DC bus current feedback is suitable for switching device protection and current limiting in most AC VSDs. Analog speed transducers are increasingly being replaced by digital devices, which are more compatible with modern digital control systems.

Malcolm Barnes

2003-01-01T23:59:59.000Z

278

Data:360311ac-6ca0-4146-89ac-db323120f125 | Open Energy Information  

Open Energy Info (EERE)

11ac-6ca0-4146-89ac-db323120f125 11ac-6ca0-4146-89ac-db323120f125 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Northern States Power Co - Minnesota Effective date: 2012/05/01 End date if known: Rate name: LIMITED OFF PEAK SERVICE Transmission Transformed (Commercial & Industrial) Sector: Commercial Description: Available to any customers for controlled loads that will be energized only for the time period between 10:00 p.m. to 6:30 a.m. daily. DETERMINATION OF CUSTOMER BILLS Customer bills shall reflect energy charges (if applicable) based on customer's kWh usage, plus a customer charge (if applicable), plus demand charges (if applicable) based on customer's kW billing demand as defined. INTERIM RATE ADJUSTMENT A 4.49% Interim Rate Surcharge will be applied to rate components specified in the "Interim Rate Surcharge Rider." In addition, customer bills under this rate are subject to the following adjustments and/or charges. FUEL CLAUSE Bills are subject to the adjustments provided for in the Fuel Clause Rider. RESOURCE ADJUSTMENT Bills are subject to the adjustments provided for in the Conservation Improvement Program Adjustment Rider, the State Energy Policy Rate Rider, the Renewable Development Fund Rider, the Transmission Cost Recovery Rider, the Renewable Energy Standard Rider and the Mercury Cost Recovery Rider.

279

Non-Federal Participation in AC Intertie Final Environmental Impact Statement Volume2:Appendices  

Broader source: Energy.gov (indexed) [DOE]

Non-Federal Participation in AC Intertie Final Non-Federal Participation in AC Intertie Final Environmental Impact Statement Volume2:Appendices Bonneville DOE/eis- 0145 POWER ADMINISTRATION January 1994 Non-Federal Participation in AC Intertie Draft Environmental Impact Statement Table of Contents Appendix A Life-of-Facilities Capacity Ownership Proposal A1 Appendix B Long-Term Intertie Access Policy B1 Appendix C Glossary C1 Appendix D Biological Assessment ad Supporting Materials

280

Contract DE-AC05-76RL01830 Modification M947  

E-Print Network [OSTI]

Contract DE-AC05-76RL01830 Modification M947 J-F-i Part III ­ List of Documents, Exhibits;Contract DE-AC05-76RL01830 Modification M947 J-F-1 OPERATIONAL AGREEMENT BETWEEN THE OFFICE OF SCIENCE;Contract DE-AC05-76RL01830 Modification M947 J-F-2 OPERATIONAL AGREEMENT BETWEEN THE OFFICE OF SCIENCE

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Contract No.: DE-AC02-09CH11466 Section J Appendix I  

E-Print Network [OSTI]

Contract No.: DE-AC02-09CH11466 Section J ­ Appendix I M160 J-I-1 ATTACHMENT J.9 APPENDIX I DOE DIRECTIVES / LIST B Applicable to the Operation of PPPL Contract No. DE-AC02-09CH11466 #12;Modification 0160 Contract No.: DE-AC02-09CH11466 Section J ­ Appendix I J-I-2 DOE Directive Date Title ES&H O 150.1A 03

282

Contract No.: DE-AC02-09CH11466 ATTACHMENT J.4  

E-Print Network [OSTI]

Contract No.: DE-AC02-09CH11466 Section J Appendix D J-D-1 ATTACHMENT J.4 APPENDIX D BUDGET PROGRAM Applicable to the Operation of PPPL Contract No. DE-AC02-09CH11466 #12;Contract No.: DE-AC02-09CH11466 Section J Appendix D J-D-2 BUDGET PROGRAM This Appendix implements the clause of this contract entitled

Princeton Plasma Physics Laboratory

283

Contract No. DE-AC02-09CH11466 Section J Appendix G  

E-Print Network [OSTI]

Contract No. DE-AC02-09CH11466 Section J ­ Appendix G M135 J-G-1 ATTACHMENT J.7 APPENDIX G PURCHASING SYSTEM REQUIREMENTS Applicable to the Operation of PPPL Contract No. DE-AC02-09CH11466 #12;Contract No. DE-AC02-09CH11466 Section J ­ Appendix G M135 J-G-2 Appendix G Purchasing System Requirements

Princeton Plasma Physics Laboratory

284

Contract Number: DE-AC05-76RL01830 Modification M971  

E-Print Network [OSTI]

Contract Number: DE-AC05-76RL01830 Modification M971 PART III ­ List of Documents, Exhibits-Owned Facilities and Real Property J-J-i #12;Contract Number: DE-AC05-76RL01830 Modification M971 ADVANCE AGREEMENT that in consideration of the extension of Contract No. DE- AC05-76RL01830 (hereinafter referred to as "the PNNL Prime

285

Programmable AC power supply for simulating power transient expected in fusion reactor  

SciTech Connect (OSTI)

This paper focus on control engineering of the programmable AC power source which has capability to simulate power transient expected in fusion reactor. To generate the programmable power source, AC-AC power electronics converter is adopted to control the power of a set of heaters to represent the transient phenomena of heat exchangers or heat sources of a fusion reactor. The International Thermonuclear Experimental Reactor (ITER) plasma operation scenario is used as the basic reference for producing this transient power source. (authors)

Halimi, B. [Seoul National Univ., Seoul 151-744 (Korea, Republic of); Suh, K. Y. [Seoul National Univ., Seoul 151-744 (Korea, Republic of); PHILOSOPHIA, 1 Gwanak Ro, Gwanak Gu, Seoul 151-744 (Korea, Republic of)

2012-07-01T23:59:59.000Z

286

Nonlinear modal interaction in HVDC/AC power systems with dc power modulation  

SciTech Connect (OSTI)

In this paper investigation of nonlinear modal interaction using the normal form of vector fields technique is extended to HVDC/AC power systems with dc power modulation. The ac-dc interface equations are solved to form a state space model with second order approximation. Using the normal form technique, the system`s nonlinear dynamic characteristics are obtained. The proposed approach is applied to a 4-generator HVDC/AC test power system, and compare with the time domain solution.

Ni, Y.X. [Tsinghua Univ., Beijing (China)] [Tsinghua Univ., Beijing (China); Vittal, V.; Kliemann, W.; Fouad, A.A. [Iowa State Univ., Ames, IA (United States)] [Iowa State Univ., Ames, IA (United States)

1996-11-01T23:59:59.000Z

287

E-Print Network 3.0 - ac electrical conductivity Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

(2004) 1726 Highly conductive ordered heterogeneous ion-exchange membranes Summary: -exchange membranes was developed. It was found that application of an ac electric field... but...

288

E-Print Network 3.0 - ac railway power-line Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Information Sciences 17 MEASUREMENT AND ANALYSIS OF ELECTROMAGNETIC FIELDS FROM TRAMS, TRAINS AND HYBRID CARS Summary: (AC or DC). Railway safety signalling systems also use...

289

E-Print Network 3.0 - ac transit demos Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Streaming Application Summary: , United Kingdom Email: bocek--hecht--hausheer--stiller@ifi.uzh.ch, yehia@comp.lancs.ac.uk Abstract... --This demo shows the CompactPSH...

290

E-Print Network 3.0 - acs residual ischemic Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Search Sample search results for: acs residual ischemic Page: << < 1 2 3 4 5 > >> 1 Brain Research 961 (2003) 2231 www.elsevier.comlocatebrainres Summary: further...

291

Bilateral field advantage in visual crowding Ramakrishna Chakravarthi a,c,*, Patrick Cavanagh b,c  

E-Print Network [OSTI]

Bilateral field advantage in visual crowding Ramakrishna Chakravarthi a,c,*, Patrick Cavanagh b, Hariharan, & Klein, 2002; Pelli, Palomares, & Majaj, 2004). Although several hypotheses have been put

Chakravarthi, Ramakrishna

292

E-Print Network 3.0 - ac joint reconstruction Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

reconstructed uniquely and stably from measurement data, ac- quired at all source... TOMOGRAPHY 205 Fig. 5. Reconstructed images corresponding to the noise model in ... Source:...

293

Non-Federal Participation In Ac Intertie Final Environmental Impact Statement  

Broader source: Energy.gov (indexed) [DOE]

Non-Federal Participation In Ac Intertie Non-Federal Participation In Ac Intertie Final Environmental Impact Statement Volume 1: Environmental Analysis Bonneville DOE/eis-0145 POWER ADMINISTRATION January 1994 Non-Federal Participation in AC Intertie Final Environmental Impact Statement (DOE/EIS - 0145) Responsible Agency: U.S. Department of Energy, Bonneville Power Administration (BPA) Title of Proposed Action: Non-Federal Participation in AC Intertie States and Other Areas Involved: Washington, Oregon, Idaho, Montana, California, Nevada, Utah, New Mexico, Arizona, Wyoming, British Columbia Abstract: BPA is considering action in two areas: (1) non-Federal access to

294

Self-Excited ac High Voltage Generation Using Water Droplets  

Science Journals Connector (OSTI)

By letting water drops fall through rings into cans high voltage can be spontaneously generated with no external electrical excitation. Previous work concerning this type of electric influence machine for dc and three-phase ac high voltage generation is extended to include multiphase multifrequency operation by considering N streams and N cans. A distributed equivalent circuit representation is used to calculate the natural frequencies of the system where it is found that many overstable modes are present. Experimental observations with up to five cans are presented. This device can serve as a model for phenomena concerned with atmospheric electricity.

Markus Zahn

1973-01-01T23:59:59.000Z

295

A Generalized Class of Stationary Frame-Current Controllers for Grid-Connected ACDC Converters  

E-Print Network [OSTI]

Within power systems, high-power pulsewidth-modulated ac-dc converters are used in flexible ac transmission systems controllers and for interfacing renewable energy sources to the grid. These converters traditionally ...

Hwang, J. George

296

LinShim6 -Implementation of the Shim6 protocol http://inl.info.ucl.ac.be/LinShim6  

E-Print Network [OSTI]

LinShim6 - Implementation of the Shim6 protocol http://inl.info.ucl.ac.be/LinShim6 Documentation at http://inl.info.ucl. ac.be/publications/shim6-masterthesis. Like the whole project, this documentation

Bonaventure, Olivier

297

A molecular approach to combat spatio-temporal variation in insecticidal gene (Cry1Ac) expression in cotton  

Science Journals Connector (OSTI)

Spatio-temporal expression of an insecticidal gene (Cry1Ac) in pre existing transgenic lines of transgenic cotton was studied. Seasonal decline in expression of Cry1Ac differed significantly among different cotto...

Allah Bakhsh; Saima Siddique; Tayyab Husnain

2012-01-01T23:59:59.000Z

298

Data:A865370d-061c-4ac0-bad4-a28ee66d26ac | Open Energy Information  

Open Energy Info (EERE)

d-061c-4ac0-bad4-a28ee66d26ac d-061c-4ac0-bad4-a28ee66d26ac No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of St Marys, Ohio (Utility Company) Effective date: 2001/06/10 End date if known: Rate name: Commercial General Service Distribution Rate 128 Sector: Commercial Description: *This rate schedule is available for lighting and power for those customers establishing a minimum demand of 1,000 KW and who enter into a Service Agreement with the City for the purchase from the City of St. Marys for its electric energy requirements. Character of service:Service will be Three (3) Phase, Alternating Current, 60 Hertz, 12,470 Volts unregulated.

299

Data:537e7901-a057-48d1-ac7a-c08908a00772 | Open Energy Information  

Open Energy Info (EERE)

-a057-48d1-ac7a-c08908a00772 -a057-48d1-ac7a-c08908a00772 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Jasper, Indiana (Utility Company) Effective date: 2009/09/01 End date if known: Rate name: Municipal Street Light (400 W Mercury Vapor) Sector: Lighting Description: Applicable only for street, alley and park lighting and traffic signals of the City of Jasper. Source or reference: ISU Documentation Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months): Service Voltage Minimum (V): Maximum (V):

300

Data:1f029483-379f-4568-ac06-8bd5cb1ac7b0 | Open Energy Information  

Open Energy Info (EERE)

3-379f-4568-ac06-8bd5cb1ac7b0 3-379f-4568-ac06-8bd5cb1ac7b0 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Holy Cross Electric Assn, Inc Effective date: 2011/07/01 End date if known: Rate name: STREET, HIGHWAY AND AREA LIGHTING: 100 Watt HPS Sector: Lighting Description: This rate applies when all fixtures are mounted on Holy Cross wood poles, either primary or secondary. Source or reference: http://www.holycross.com/about-us/rates-charges Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months):

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Data:D0f4ac6d-44e2-4291-93ac-7bad270f8d9b | Open Energy Information  

Open Energy Info (EERE)

ac6d-44e2-4291-93ac-7bad270f8d9b ac6d-44e2-4291-93ac-7bad270f8d9b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Cooperative L&P Assn Lake Cnty Effective date: 2012/01/01 End date if known: Rate name: Heat Pumps Sector: Residential Description: Both Air-source and Ground-source heat pumps use either the dual fuel or general service rate, depending on if you install a back-up heating system. Note: General service rates apply until back up fuel system is installed and operational. Contact your local heating contractor for any equipment information. Source or reference: http://www.clpower.com/?p=14

302

Data:304c7bdb-9ac5-4bea-ab51-af99e3f22ac3 | Open Energy Information  

Open Energy Info (EERE)

bdb-9ac5-4bea-ab51-af99e3f22ac3 bdb-9ac5-4bea-ab51-af99e3f22ac3 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Cuming County Public Pwr Dist Effective date: 2011/12/14 End date if known: Rate name: Security Lighting Unmetered Lights 400W MV Sector: Lighting Description: Source or reference: Ilinois State University Rate binder # 10 Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months): Service Voltage Minimum (V): Maximum (V): Character of Service Voltage Category: Phase Wiring: << Previous 1 2 3 Next >>

303

Data:E710dbca-01f1-41b8-a2ac-9680233ac368 | Open Energy Information  

Open Energy Info (EERE)

dbca-01f1-41b8-a2ac-9680233ac368 dbca-01f1-41b8-a2ac-9680233ac368 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Stafford, Kansas (Utility Company) Effective date: End date if known: Rate name: E6 - 155 Horsepower Sector: Commercial Description: Source or reference: https://cas.sharepoint.illinoisstate.edu/grants/Sunshot/Lists/DATA%20ENTRY%20Rates%20Collected/Attachments/627/rate%20information%20for%20Stafford.pdf Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months): Service Voltage Minimum (V):

304

Data:Cd66912f-ac4c-4a5f-ac64-750948dd9b7f | Open Energy Information  

Open Energy Info (EERE)

2f-ac4c-4a5f-ac64-750948dd9b7f 2f-ac4c-4a5f-ac64-750948dd9b7f No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Farmers' Electric Coop, Inc (New Mexico) Effective date: 2010/05/01 End date if known: Rate name: Small Commercial Sector: Commercial Description: Source or reference: Rate Binder#8 (Illinois State University) Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months): Service Voltage Minimum (V): Maximum (V): Character of Service Voltage Category: Phase Wiring: << Previous 1 2 3 Next >> << Previous

305

Study of Ionic Conductivity Profiles of the Air Cathode of a PEMFC by AC Impedance Spectroscopy  

E-Print Network [OSTI]

Study of Ionic Conductivity Profiles of the Air Cathode of a PEMFC by AC Impedance Spectroscopy membrane fuel cell PEMFC cathode by ac impedance measurement at open-circuit potential conditions by impregnating a proton-conducting ionomer in the catalyst active layer of the cathode of a polymer electrolyte

306

Power control of a wind farm with active stall wind turbines and AC grid connection  

E-Print Network [OSTI]

Power control of a wind farm with active stall wind turbines and AC grid connection Anca D. Hansen1 controller for a wind farm made-up exclusively of active stall wind turbines with AC grid connection wind farm control involves both the control on wind turbine level as well as the central control

307

Synthesis Gas Production from Partial Oxidation of Methane with Air in AC Electric Gas Discharge  

E-Print Network [OSTI]

Synthesis Gas Production from Partial Oxidation of Methane with Air in AC Electric Gas Discharge K 73019 Received October 11, 2002 In this study, synthesis gas production in an AC electric gas discharge of methane and air mixtures at room temperature and ambient pressure was investigated. The objective

Mallinson, Richard

308

NEW ASPECTS OF SOME SMALL-SIGNAL ac FREQUENCY RESPONSE FUNCTIONS J. Ross MACDONALD  

E-Print Network [OSTI]

NEW ASPECTS OF SOME SMALL-SIGNAL ac FREQUENCY RESPONSE FUNCTIONS J. Ross MACDONALD Department. It was shown by Macdonald and Cook [5] that an admittance closely related to eq. (1) with n 1 = 0 and n 2 = n]. This analysis showed that #12;160 J. Ross Macdonald/Small-signal ac frequency response functions the data did

Macdonald, James Ross

309

Contract Number: DE-AC05-76RL01830 Modification M920  

E-Print Network [OSTI]

Contract Number: DE-AC05-76RL01830 Modification M920 Part III ­ List of Documents, Exhibits, And Other Attachments Section J List of Attachments J ­ i #12;Contract Number: DE-AC05-76RL01830

310

ForReview.Confidential-ACS Plantwide Control to Economic Optimum of a Recycle  

E-Print Network [OSTI]

ForReview.Confidential-ACS Plantwide Control to Economic Optimum of a Recycle Process with Side #12;ForReview.Confidential-ACS Plantwide Control to Economic Optimum of a Recycle Process with Side, Trondheim N7491, Norway Abstract Plantwide control system design for economically optimum operation

Skogestad, Sigurd

311

Penetration of ac magnetic field into bulk high-temperature superconductors: Experiment and simulation  

E-Print Network [OSTI]

Penetration of ac magnetic field into bulk high-temperature superconductors: Experiment from these models for high-temperature superconductors are observed at the op- eration in ac fields condi- tions is very important for correct modeling magnetic prop- erties of high-temperature

Paperno, Eugene

312

Ultrafast high-pressure AC electro-osmotic pumps for portable biomedical microfluidics  

E-Print Network [OSTI]

Ultrafast high-pressure AC electro-osmotic pumps for portable biomedical microfluidics Chien details the development of an integrated AC electro-osmotic (ACEO) microfluidic pump for dilute (100 mM) biological solutions in separate microfluidic devices, with potential applications in portable

Bazant, Martin Z.

313

AC PV Modules Take a standard DC PV module and connect a microinverter  

E-Print Network [OSTI]

modules. These inverters range in power from 700 watts up to 1 megawatt. DC maximum system voltages can and up to 13 inverters for the 210 W version to be installed on the same AC output cable. home power 136, and secure a listing to UL1741 for a pre-assembled module/inverter device, and you have an AC PV module

Johnson, Eric E.

314

ePOWER Seminar AC solar cells: A new breed of PV power generation  

E-Print Network [OSTI]

ePOWER Seminar AC solar cells: A new breed of PV power generation Professor Faisal Khan Assistant dc output which needs to be processed and inverted for ac applications. Using a modern manufacturing facility, PV panels could be mass produced without any apparent issues. Unfortunately, power converters

Abolmaesumi, Purang

315

Superconducting Cables for a.c. and d.c. Power Transmission  

Science Journals Connector (OSTI)

...1973 research-article Superconducting Cables for a.c. and d.c. Power Transmission...power transmission lines. Some present cables are water cooled to increase their current...both a.c. and d.c. superconducting cables are described, with particular attention...

1973-01-01T23:59:59.000Z

316

A New ACS Audio Course to help you understand and solve industrial and municipal waste-water problems ....  

Science Journals Connector (OSTI)

A New ACS Audio Course to help you understand and solve industrial and municipal waste-water problems .... ...

1982-08-01T23:59:59.000Z

317

Development of a 10 kW High Temperature High Power Density Three-Phase AC-DC-AC SiC Converter  

SciTech Connect (OSTI)

This paper presents the development and experimental performance of a 10 kW, all SiC, 250 C junction temperature high-power-density three-phase ac-dc-ac converter. The electromagnetic interference filter, thermal system, high temperature package, and gate drive design are discussed in detail. Finally, tests confirming the feasibility and validating the theoretical basis of the prototype converter system are described.

Ning, Puqi [ORNL

2012-01-01T23:59:59.000Z

318

436 IEEE/ASME TRANSACTIONS ON MECHATRONICS, VOL. 9, NO. 2, JUNE 2004 Torque and Velocity Ripple Elimination of AC  

E-Print Network [OSTI]

Elimination of AC Permanent Magnet Motor Control Systems Using the Internal Model Principle Wai-Chuen Gan and velocity ripple elimination in AC permanent magnet (PM) motor control systems. The torque ripples caused-free output response. Index Terms--AC permanent magnet motor, gain scheduled (GS) speed regulators, internal

Qiu, Li

319

Choice set options affect the valuation of risky prospects Stian Reimers (stian.reimers@warwick.ac.uk)  

E-Print Network [OSTI]

.reimers@warwick.ac.uk) Neil Stewart (neil.stewart@warwick.ac.uk) Nick Chater (nick.chater@warwick.ac.uk) Department to deciding whether to invest in shares or bonds, we have to come to decisions based on the merits

Chater, Nick

320

COUNTRY INSTITUTION DATE WEB ADDRESS IRAN University of Art Isfahn 08.03.2007 http://www.aui.ac.ir  

E-Print Network [OSTI]

COUNTRY INSTITUTION DATE WEB ADDRESS IRAN University of Art Isfahn 08.03.2007 http://www.aui.ac.ir IRAN Isfahn University of Technology 08.03.2007 http://www.iut.ac.ir IRAN The University of Isfahn 15/03/2011 http://www.ui.ac.ir IRAN Shahid Bahonar University of Kermn 06.06.2005 http

Di Pillo, Gianni

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

The scaling of transport AC losses in Roebel cables with varying strand parameters  

Science Journals Connector (OSTI)

A Roebel cable is a good candidate for low-voltage windings in a high-temperature superconductor (HTS) transformer because of its high current-carrying capability and low AC loss. Transport AC loss measurements were carried out in 1.8 m long 15/5 (fifteen 5 mm wide strands) and 15/4 Roebel cables. The results were compared with those in many Roebel cables composed of 2 mm wide Roebel strands. Comparison of the AC losses hinted that the intrinsic difference in normalized transport AC losses is due to differences in the g/w (ratio of the horizontal gap between the Roebel strands over the Roebel strand width) values. The intrinsic difference was confirmed by measuring transport AC loss in a series of horizontally arranged parallel conductor pairs with various g values. A method to scale transport AC losses in Roebel cables with varying strand parameters was developed. The scaling method will be useful for a rough assessment of AC loss in one-layer solenoid winding coils, such as in a HTS transformer.

Zhenan Jiang; Mike Staines; Nicholas J Long; Rodney A Badcock; Chris Bumby; Evgeny Talantsev; Kent Hamilton; Robert G Buckley; Naoyuki Amemiya

2014-01-01T23:59:59.000Z

322

Copyright 1999 The Association of Universities for Research in Astronomy, Inc. All Rights Reserved. Instrument Science Report ACS 2000-03  

E-Print Network [OSTI]

relating to each item. The present ACS pipeline operations are described in ACS ISRs 99-03 (Hack), 99-04 (Mutchler et al) and 99-08 (Hack). #12;Instrument Science Report ACS 2000-03 2 II. The Geometric Issues ACS

Sirianni, Marco

323

Microsoft Word - AC Report Final LBNL format-2.docx  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

ERNEST ORLANDO LAWRENCE ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners Nihar Shah 1 , Paul Waide 2 , Amol Phadke 1 LBNL-XXXX 1 Environmental Energy Technologies Division, International Energy Studies Group, Lawrence Berkeley National Laboratory 2 Navigant Consulting, Inc. This work was funded by the Bureau of Oceans and International Environmental and Scientific Affairs, U.S. Department of State, and administered by the U.S. Department of Energy in support of the Super-efficient Equipment and Appliance Deployment (SEAD) initiative through the U.S. Department of Energy under Contract No. DE-AC02-05CH11231 i Disclaimer This document was prepared as an account of work sponsored by the United States Government in

324

DE-AC05-06OR23100  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

NOT SPECIFIED /OTHER NOT SPECIFIED /OTHER ___________ (x) x DE-AC05-06OR23100 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified. 041152224 OAK RIDGE ASSOCIATED UNIVERSITIES, INC.

325

FLUXCAP: A flux-coupled ac/dc magnetizing device  

E-Print Network [OSTI]

We report on an instrument for applying ac and dc magnetic fields by capturing the flux from a rotating permanent magnet and projecting it between two adjustable pole pieces. This can be an alternative to standard electromagnets for experiments with small samples or in probe stations in which an applied magnetic field is needed locally, with advantages that include a compact form-factor, very low power requirements and dissipation as well as fast field sweep rates. This flux capture instrument (FLUXCAP) can produce fields from -400 to +400 mT, with field resolution less than 1 mT. It generates static magnetic fields as well as ramped fields, with ramping rates as high as 10 T/s. We demonstrate the use of this apparatus for studying the magnetotransport properties of spin-valve nanopillars, a nanoscale device that exhibits giant magnetoresistance.

Gopman, Daniel B; Kent, Andrew D

2012-01-01T23:59:59.000Z

326

Phase-locking of driven vortex lattices with transverse ac force and periodic pinning  

SciTech Connect (OSTI)

For a vortex lattice moving in a periodic array we show analytically and numerically that a new type of phase locking occurs in the presence of a longitudinal dc driving force and a transverse ac driving force. This phase locking is distinct from the Shapiro step phase locking found with longitudinal ac drives. We show that an increase in critical current and a fundamental phase-locked step width scale with the square of the driving ac amplitude. Our results should carry over to other systems such as vortex motion in Josephson-junction arrays.

Reichhardt, Charles; Kolton, Alejandro B.; Dominguez, Daniel; Gronbech-Jensen, Niels

2001-10-01T23:59:59.000Z

327

Application of direct pulsewidth modulation scheme to AC-DC converters: - a way to reduce ripple  

E-Print Network [OSTI]

and Problems . 2 Switching Transfer Function . 3 General Theory of PWM 4 Performance Measurement of PWM sc-dc Coverters 1 5 8 12 ALGORITHM OF DIRECT PULSEWIDTH MODULATION USED IN AC- DC COVERTER 14 SINGLE PHASE AC-DC PWM CONVERTERS . . 17 ac..., and ISPWM. 3. 1 Sinusoidal Pulsewidth Modulation (SPWM) SPWM is the most commonly used PWM technique. In SPWM as shown in Figure 1, the pulse widths are generated by comparing a carrier signal which is made of CARRIER REFERENCE 0 0 I . 0 1. 5 20 2. 5...

Zhang, Yuemin

2012-06-07T23:59:59.000Z

328

Dynamic performance of a STATCON at an HVDC inverter feeding a very weak AC system  

SciTech Connect (OSTI)

This paper investigates the dynamic performance of the advanced static var compensator or STATCON at a high voltage direct current (HVDC) converter terminal where the ac system has a very low short circuit ratio (SCR). The STATCON is based on a nine-level GTO thyristor inverter. The studies include operating characteristics of the STATCON under various ac and dc disturbances. The simulation results are compared with other types of reactive power compensation options available for such applications. It is shown that the STATCON has clear advantages over the other compensators, in areas such as; fault response time, voltage support ability, and dc recovery, while operating with very weak ac systems.

Zhuang, Y.; Menzies, R.W. [Univ. of Manitoba, Winnipeg, Manitoba (Canada)] [Univ. of Manitoba, Winnipeg, Manitoba (Canada); Nayak, O.B. [HVDC Research Centre, Winnipeg, Manitoba (Canada)] [HVDC Research Centre, Winnipeg, Manitoba (Canada); Turanli, H.M. [Manitoba Hydro, Winnipeg, Manitoba (Canada)] [Manitoba Hydro, Winnipeg, Manitoba (Canada)

1996-04-01T23:59:59.000Z

329

EMTP modeling of CIGRE benchmark based HVDC transmission system operating with weak AC systems  

SciTech Connect (OSTI)

An EMTP based study of a CIGRE benchmark based HVDC system operating with weak ac systems is carried out. The modeled system provides a starting point for (a) educators teaching HVDC transmission courses and (b) for utility planners to develop their own low-cost dedicated digital simulators for training purposes. In this paper, modeling details of the ac-dc system, dc converters and control are presented. To validate the control schemes presented, the HVDC system is tested under ac-dc fault conditions. Results obtained from an EMTP-based study under these fault conditions are also presented in this paper.

Sood, V.K. [Hydro-Quebec, Varennes, Quebec (Canada); Khatri, V.; Jin, H. [Concordia Univ., Montreal, Quebec (Canada). Dept. of Electrical and Computer Engineering

1995-12-31T23:59:59.000Z

330

Copyright 1999 The Association of Universities for Research in Astronomy, Inc. All Rights Reserved. Instrument Science Report ACS 2001-10  

E-Print Network [OSTI]

. Instrument Science Report ACS 2001-10 ACS software tool development W.B. Sparks, W.J. Hack, M. Clampin-3 (Sparks et al). The ACS pipeline operations are described in ACS ISRs 99-03 (Hack), 99-04 (Mutchler et al) and 99-08 (Hack). #12;Instrument Science Report ACS 2001-10 2 PyDrizzle and calacs We expect OPUS 13

Sirianni, Marco

331

A Test of Vehicle-to-Grid (V2G) for Energy Storage and Frequency Regulation in the PJM  

E-Print Network [OSTI]

of Vehicle-to-Grid power, providing real-time frequency regulation from an electric car. Vehicle-to-Grid (V2G) presents a mechanism to meet key requirements of the electric power system, using electric vehicles when, freeway-capable electric vehicle was used in this study. Its power electronics are designed to both drive

Firestone, Jeremy

332

Did geomagnetic activity challenge electric power reliability during solar cycle 23? Evidence from the PJM regional transmission  

E-Print Network [OSTI]

Did geomagnetic activity challenge electric power reliability during solar cycle 23? Evidence from of America, Washington, DC, 20064 USA Chris.StCyr@nasa.gov #12;Abstract During Solar Cycle 22, a very intense geomagnetic storm on 13 March 1989 contributed to the collapse of the Hydro-Quebec power system in Canada

Schrijver, Karel

333

Greener Commercial A/C Units Becoming a Cool Item | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Greener Commercial A/C Units Becoming a Cool Item Greener Commercial A/C Units Becoming a Cool Item Greener Commercial A/C Units Becoming a Cool Item July 1, 2010 - 5:11pm Addthis Greener Commercial A/C Units Becoming a Cool Item Stephen Graff Former Writer & editor for Energy Empowers, EERE A new federal tax credit is helping McQuay International expand its line of energy-efficient HVAC products at two of its plants and bring back furloughed workers. With the help of a 48C manufacturing tax credit worth $2 million under the American Recovery and Reinvestment Act, McQuay's Minnesota and Virginia plants have been or will be upgraded and expanded to produce new lines of energy efficient products. The tax credit is playing a role, but offering a bigger-and more efficient-selection of HVAC products also came down to basic economics:

334

www.exeter.ac.uk/inspiring-science Cellulose: sustainable and renewable  

E-Print Network [OSTI]

www.exeter.ac.uk/inspiring-science Cellulose: sustainable and renewable material for many The talk will cover the use of cellulose as a sustainable and renewable source for use in composites

Mumby, Peter J.

335

December 26, 2012 12:27 WSPC/INSTRUCTION FILE acs-revision-disagreementreviews-v2  

E-Print Network [OSTI]

December 26, 2012 12:27 WSPC/INSTRUCTION FILE acs-revision- disagreementreviews-v2 Advances and cultural structures that anticipate, in part or in whole, this kind of collabo- 1 #12;December 26, 2012 12

Grimaldo, Francisco

336

AC 2010-343: NASA SENIOR DESIGN: MISSION ASSURANCE MANAGEMENT ENVIRONMENT  

E-Print Network [OSTI]

this challenge, we propose to improve spacecraft building and operating processes with integrated software, design, implementation, system integration, validation and test. Identification of System RequirementsAC 2010-343: NASA SENIOR DESIGN: MISSION ASSURANCE MANAGEMENT ENVIRONMENT Jiang Guo, California

Conrad, James M.

337

E-Print Network 3.0 - ac mode comparative Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: mode analyses for Mercier stable and*E-mail: nakajima@nifs.ac.jp FUSION SCIENCE AND TECHNOLOGY VOL. 51... by comparing the eigenvalues obtained by global mode...

338

E-Print Network 3.0 - acs lcid project Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

for optimizing Summary: workflow execution Tristan Glatard a,b,c, Johan Montagnat a,c David Emsellem c Diane Lingrand c,a aI3S... -line tool is described with the LCID (Legacy...

339

E-Print Network 3.0 - ac quantum transport Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

1 2 3 4 5 > >> 1 Quantum Hall Transitions Summary: - Coddington Model Quantum Phase Transition von Klitzing's discovery Source: warwick.ac.uk RH 1 n h e2 (n 1... Quantum Phase...

340

MIT Electric Vehicle Team Porsche designing a cooling system for the AC24 electric motor  

E-Print Network [OSTI]

In this thesis I worked on the design and analysis of a cooling system for the electric motor of the MIT Electric Vehicle Team's Porsche 914 Battery Electric Vehicle. The vehicle's Azure Dynamics AC24 motor tended to ...

Meenen, Jordan N

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Dimmable AC LED Driver With Efficiency Improved Based on Switched LED Module  

Science Journals Connector (OSTI)

In this paper, one AC light-emitting diode (LED) driver with high power factor (PF) and low total harmonic distortion (THD) is adopted, which is added with the proposed...

Hwu, K I; Tu, W C; Fang, Y T

2014-01-01T23:59:59.000Z

342

E-Print Network 3.0 - ac phase noise Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Laser Amplitude and Phase Summary: Floor In a phase-noise setup, system noise floor verification is ac- complished by driving both ports... -Dynamic-Range Laser Amplitude and...

343

acs_NL_nl-2011-03332e 1..8  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

| Nano Lett. 2011, 11, 5071-5078 LETTER pubs.acs.orgNanoLett Hierarchically Porous Graphene as a LithiumAir Battery Electrode Jie Xiao,* , Donghai Mei, Xiaolin Li, ...

344

Measured Savings of DC to AC Drive Retrofit in Plastic Extrusion  

E-Print Network [OSTI]

This paper presents the potential electrical energy efficiency improvements for utilizing alternating current (AC) motors controlled by variable frequency drives (VFD) in place of direct current (DC) motors to drive plastic extrusion machines. A...

Sfeir, R. A.

2008-01-01T23:59:59.000Z

345

Division of Chemical Education Program for the Fall 2010 ACS National Meeting in Boston  

Science Journals Connector (OSTI)

Division of Chemical Education Program for the Fall 2010 ACS National Meeting in Boston ... The Undergraduate Research Poster and Sci-Mix will be held in the Boston Convention and Exhibition Center. ... General Posters ...

Julie Smist; Nicole L. Snyder; Carmen Valdez Gauthier

2010-06-17T23:59:59.000Z

346

E-Print Network 3.0 - ac electric arc Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Search Powered by Explorit Topic List Advanced Search Sample search results for: ac electric arc Page: << < 1 2 3 4 5 > >> 1 The response of the azimuthal component of the...

347

Quick surface treatment of AZ31B by AC micro-arc oxidation  

Science Journals Connector (OSTI)

In order to explore an effective way to shorten treatment time and enhance the quality of treatment coating, AC micro-arc oxidation was conducted to treat the surface of ... KF+KOH treatment solution. The influen...

Shenglin Wang ???; Peng Zhang ??; Yunhui Du

2014-08-01T23:59:59.000Z

348

Docket No. EERE-2012-BT-TP-0046; RIN 1904-AC52 Ex partecommunication...  

Broader source: Energy.gov (indexed) [DOE]

Ex parte communication Meeting of May 16, 2013 Docket No. EERE-2012-BT-TP-0046; RIN 1904-AC52 Ex parte communication Meeting of May 16, 2013 This memorandum for the record...

349

Carbon nanostructures production by AC arc discharge plasma process at atmospheric pressure  

Science Journals Connector (OSTI)

Carbon nanostructures have received much attention for a wide range of applications. In this paper, we produced carbon nanostructures by decomposition of benzene using AC arc discharge plasma process at atmospheric pressure. Discharge was carried out ...

Shenqiang Zhao; Ruoyu Hong; Zhi Luo; Haifeng Lu; Biao Yan

2011-01-01T23:59:59.000Z

350

E-Print Network 3.0 - ac loss measurement Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Plants 9 Journal of High Speed Networks 13 (2004) 87102 87 An implementation-based comparison of Summary: loss ratio. Using AC-MVE, an algorithm based upon mean and variance...

351

Vibrational, giant dielectric and AC conductivity properties of agglomerated CuO nanostructures  

Science Journals Connector (OSTI)

We report frequency, temperature dependent dielectric response and AC conductivity of nanocrystalline CuO. These nanoparticles were prepared using solgel technique. Prepared particles were made as a pellet us...

K. R. Deepthi; T. Pandiyarajan

2013-03-01T23:59:59.000Z

352

DE-AC27-10RV15051 Modification A001  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

may be for any casino or other gambling establishment, aquarium, zoo, golf course, or swimming pool. DE-AC27-10RV15051 Modification A001 Page 7 of 12 D. Wage Rates All laborers...

353

E-Print Network 3.0 - ac stark shifts Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

in Figure 3A,C, we uncover the unusually broad higher order Stark line... to electrochromic band shifts which have been analyzed in detail elsewhere.9 The 2 Stark spectrum of...

354

Alameda-Contra Costa Transit District (AC Transit) Fuel Cell Transit Buses: Preliminary Evaluation Results  

SciTech Connect (OSTI)

This report provides an evaluation of three prototype fuel cell-powered transit buses operating at AC Transit in Oakland, California, and six baseline diesel buses similar in design to the fuel cell buses.

Chandler, K.; Eudy, L.

2007-03-01T23:59:59.000Z

355

Contract No. DE-AC02-09CH11466 CONTRACT CLAUSES  

E-Print Network [OSTI]

Contract No. DE-AC02-09CH11466 Section I M152 I-i PART II SECTION I CONTRACT CLAUSES TABLE THE GOVERNMENT'S INTEREST WHEN SUBCONTRACTING WITH CONTRACT

Princeton Plasma Physics Laboratory

356

AC-LED based Visible Light Communication Systems Using Multiple Transmitter Design for Reducing Latency  

Science Journals Connector (OSTI)

This work demonstrates by employing multiple alternating-current light-emitting-diode (AC-LED) communication modules, the transmission gap in time-domain caused by the LED threshold...

Liu, Y; Yeh, C; Chow, C W

357

AC 2007-253: ENCOURAGING CREATIVITY IN INTRODUCTORY COMPUTER SCIENCE PROGRAMMING ASSIGNMENTS  

E-Print Network [OSTI]

AC 2007-253: ENCOURAGING CREATIVITY IN INTRODUCTORY COMPUTER SCIENCE PROGRAMMING ASSIGNMENTS Tammy technology, multimedia, software engineering, and CS theory. © American Society for Engineering Education, 2007 #12;Encouraging Creativity in Introductory Computer Science Programming Assignments Abstract

VanDeGrift, Tammy

358

E-Print Network 3.0 - ac transit fuel Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Sample search results for: ac transit fuel Page: << < 1 2 3 4 5 > >> 1 Hydrogen and Fuel Cell Vehicle Evaluation Richard Parish, Leslie Eudy, and Ken Proc Summary: and the...

359

LHC (SCGT12) http://cale.law.nagoya-u.ac.jp/2012CALEis/  

E-Print Network [OSTI]

- 23 LHC (SCGT12) 10 #12; of http://cale.law.nagoya-u.ac.jp/2012CALEis-789-2773 124() 7() KMI/COE LHC (SCGT12) 1 9001700 052-789-2862 124() ES1ES 13001625 nakajima

Takahashi, Ryo

360

Development and application of setup for ac magnetic field in neutron scattering experiments  

SciTech Connect (OSTI)

We report on a new setup developed for neutron scattering experiments in periodically alternating magnetic fields at the sample position. The assembly consisting of rf generator, amplifier, wide band transformer, and resonance circuit. It allows to generate homogeneous ac magnetic fields over a volume of a few cm{sup 3} and variable within a wide range of amplitudes and frequencies. The applicability of the device is exemplified by ac polarized neutron reflectometry (PNR): a new method established to probe remagnetization kinetics in soft ferromagnetic films. Test experiments with iron films demonstrate that the ac field within the accessible range of frequencies and amplitudes produces a dramatic effect on the PNR signal. This shows that the relevant ac field parameters generated by the device match well with the scales involved in the remagnetization processes. Other possible applications of the rf unit are briefly discussed.

Klimko, Sergey [Laboratoire Leon Brillouin, 91191 Gif-sur-Yvette (France); Zhernenkov, Kirill; Toperverg, Boris P.; Zabel, Hartmut [Institut fuer Festkoerperphys IV, Ruhr Universitaet Bochum, D-44780 Bochum (Germany)

2010-10-15T23:59:59.000Z

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Alameda-Contra Costa Transit District (AC Transit) Fuel Cell Transit Buses: Preliminary Evaluation Results  

Broader source: Energy.gov [DOE]

This report provides an evaluation of three prototype fuel cell-powered transit buses operating at AC Transit in Oakland, California, and six baseline diesel buses similar in design to the fuel cell buses.

362

Summary Non-Federal Participation in AC Intertie Final Environmental Impact Statement  

Broader source: Energy.gov (indexed) [DOE]

Non-Federal Participation in AC Intertie Final Non-Federal Participation in AC Intertie Final Environmental Impact Statement Background In April 1988, Bonneville Power Administration (BPA) published the Intertie Development and Use Environmental Impact Statement (IDU eis). This eis studied the environmental and economic effects of the use of the Pacific Northwest-Southwest Intertie (Intertie), including the proposed Third Alternating Current (Third AC) Intertie addition. The Third AC project is part of the Intertie, authorized by Congress to accomplish three major objectives: (1) to provide an additional market for surplus BPA power to enable BPA to increase its revenues and thereby help BPA repay the U.S. Treasury in a timely manner; (2) to serve loads in the Pacific Northwest

363

AEP (Central and SWEPCO) - Coolsaver A/C Tune Up | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AEP (Central and SWEPCO) - Coolsaver A/C Tune Up AEP (Central and SWEPCO) - Coolsaver A/C Tune Up AEP (Central and SWEPCO) - Coolsaver A/C Tune Up < Back Eligibility Commercial Installer/Contractor Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Other Home Weatherization Commercial Weatherization Sealing Your Home Ventilation Heat Pumps Program Info Funding Source AEP Texas (Central and SWEPCO) Companies State Texas Program Type Utility Rebate Program Rebate Amount $75 coupon/customer; contractor incentives Provider CLEAResult Consulting, Inc. Participating customers are eligible to receive a $75 coupon for use toward A/C and heat pump efficiency services performed as a result of the program's tune-up analysis. Residential and small commercial HVAC contractors that service customers served by SWEPCO may apply to

364

@BristolUniLib bristol.ac.uk/library Remote (off-site) access  

E-Print Network [OSTI]

Library @BristolUniLib bristol.ac.uk/library Remote (off-site) access As a member of the University network you may use one of the following options to gain network access from off-site: Remote Desktop.bristol.ac.uk/it-services/ advice/homeusers/remote/studentdesktop. Off-site Proxy The off-site proxy allows use of University web

Bristol, University of

365

An evaluation of the Panasonic model UD513AC-1 thermoluminescence dosimetry system  

E-Print Network [OSTI]

for the degree of MASTER OF SCIENCE December 1991 Major Subject: Health Physics AN EVALUATION OF THE PANASONIC MODEL UD513AC-I THERMOLUMINESCENCE DOSIMETRY SYSTEM A Thesis by RUSSELL EDWARD DURRER JR. Approved as to style and content by: John W. Poston... (Chair of Committee) Wesl E. Bolch (Member) ilton E. Mc ain (Member) Dan Hig tower (Member) John W. Poston (Head of Department) December 1991 ABSTRACT An Evaluation of the Panasonic Model UD513AC-1 Thermoluminescence Dosimetry System...

Durrer, Russell Edward

2012-06-07T23:59:59.000Z

366

Contract Number: DE-AC05-76RL01830 Modification M881  

E-Print Network [OSTI]

Contract Number: DE-AC05-76RL01830 Modification M881 Part I ­ The Schedule Section F Deliveries) Alternate I (Apr 1984) 1 F ­ 3 Deliverables 2 F ­ i #12;Contract Number: DE-AC05-76RL01830 Modification M881 F ­ 1 Period of Performance This Contract shall be effective as specified in Block No. 3 ­ Effective

367

Contract Number: DE-AC05-76RL01830 Modification M881  

E-Print Network [OSTI]

Contract Number: DE-AC05-76RL01830 Modification M881 B-i Part I ­ The Schedule Section B Supplies.......................................................1 #12;Contract Number: DE-AC05-76RL01830 Modification M881 B-1 B­1 Designation of Work in this Contract and as designated in writing from time to time by DOE, including the utilization of information

368

Contract Number: DE-AC05-76RL01830 Modification A508  

E-Print Network [OSTI]

Contract Number: DE-AC05-76RL01830 Modification A508 E-1 Part I ­ The Schedule Section E Inspection) .........................................................................1 E ­ i #12;Contract Number: DE-AC05-76RL01830 Modification A508 E-1 E ­ 1 52.246-9 Inspection the work performed or being performed under the Contract, and the premises where the work is being

369

Contract No. DE-AC02-09CH11466 INSPECTION AND ACCEPTANCE  

E-Print Network [OSTI]

Contract No. DE-AC02-09CH11466 Section E M007 i PART I SECTION E INSPECTION AND ACCEPTANCE PAGE NO ­ APPLICABLE ONLY TO THE RECOVERY ACT WORK E-1 #12;Contract No. DE-AC02-09CH11466 Section E M007 E-1 PART I performed under the contract, and the premises where the work is being performed, at all reasonable times

Princeton Plasma Physics Laboratory

370

Ac loss reduction of multilayer superconducting power transmission cables by using narrow  

Science Journals Connector (OSTI)

The ac loss characteristics of coated conductors are dominated by the magnetic field component normal to their superconductor layer. Multilayer cables as well as monolayer cables consisting of 4mm-wide coated conductors (named 4mm cables) and those consisting of 2mm-wide coated conductors (named 2mm cables) were designed, and numerical electromagnetic field analyses were performed in their cross sections to calculate their ac losses. Trapezoidal lateral critical current density Jc distributions with shoulders as well as uniform ones were assumed in coated conductors for the analyses. The former models the degraded Jc near the edges of coated conductors. In the case of the monolayer, the calculated ac losses of the 2mm cables were comparable to those of the 4mm cables. In the cases of the multilayers, the calculated ac losses of the 2mm cables were obviously less than those of the 4mm cables. The degraded Jc near the edges of coated conductors more seriously affects the ac loss characteristics of the 2mm cables than those of the 4mm cables. However, even if we consider the influence of the degraded Jc near the edges of coated conductors, 2mm-wide coated conductors are more profitable than 4mm-wide coated conductors in multilayer cables from the viewpoint of ac loss reduction.

Naoyuki Amemiya; Quan Li; Kaoru Ito; Katsutoku Takeuchi; Taketsune Nakamura; Takeshi Okuma

2011-01-01T23:59:59.000Z

371

Low Cost Fabrication of 2G Wires for AC Applications  

SciTech Connect (OSTI)

Ink-jet printing has been demonstrated as an adaptable technology for printing YBCO filaments using a Metal Organic (MO) YBCO precursor. The technology was demonstrated using AMSC's proprietary metal organic TFA-based YBCO precursor and a commercial piezoelectric print-head on RABiTS templates. Filaments with a width of 100 um and spacing of 200 um were successfully printed, decomposed and processed to YBCO. Critical currents of {approx} 200 A/cm-w were achieved in a series of filaments with a 2 mm width. The single nozzle laboratory printer used in the Phase 1 program is capable of printing {approx} 100 um wide single filaments at a rate of 8-10 cm/sec. The electrical stabilization of filaments with a Ag ink was also evaluated using ink-jet printing. The overall objective of the Phase 1 Project was the evaluation and demonstration of inkjet-printing for depositing YBCO filaments on textured templates (RABiTS, IBAD, ISD, etc. substrates) with properties appropriate for low loss ac conductors. Goals of the Phase 1 program included development of an appropriate precursor ink, demonstration of the printing process, processing and characterization of printed YBCO filaments and evaluation of the process for further development.

Kodenkandath, T.; List, F.A., III

2005-09-15T23:59:59.000Z

372

Magnetostrictive materials and method for improving AC characteristics in same  

DOE Patents [OSTI]

The present invention provides Terfenol-D alloys ("doped" Terfenol) having optimized performances under the condition of time-dependent magnetic fields. In one embodiment, performance is optimized by lowering the conductivity of Terfenol, thereby improving the frequency response. This can be achieved through addition of Group III or IV elements, such as Si and Al. Addition of these types of elements provides scattering sites for conduction electrons, thereby increasing resistivity by 125% which leads to an average increase in penetration depth of 80% at 1 kHz and an increase in energy conversion efficiency of 55%. The permeability of doped Terfenol remains constant over a wider frequency range as compared with undoped Terfenol. These results demonstrate that adding impurities, such as Si and Al, are effective in improving the ac characteristics of Terfenol. A magnetoelastic Gruneisen parameter, .gamma..sub.me, has also been derived from the thermodynamic equations of state, and provides another means by which to characterize the coupling efficiency in magnetostrictive materials on a more fundamental basis.

Pulvirenti, Patricia P. (Chicago, IL); Jiles, David C. (Ames, IA)

2001-08-14T23:59:59.000Z

373

Data:0035917e-2145-402d-ac20-617ac6c62e50 | Open Energy Information  

Open Energy Info (EERE)

e-2145-402d-ac20-617ac6c62e50 e-2145-402d-ac20-617ac6c62e50 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: CenterPoint Energy Effective date: 2013/01/25 End date if known: Rate name: Street Lighting - HPS 250 Watt SB - Existing Pole Mounts Sector: Lighting Description: Electric, LLC (CEHE or Company) where facilities of adequate capacity and suitable voltage are adjacent to the street lighting fixtures and ornamental standards (if any) to be served. The standard street lighting service provided by the Company is installed along public streets, roadways or other public access areas in accordance with Section 6.1.2.2, Construction Services, in this Tariff. Company will only provide for the delivery of electric power and energy, the street lighting fixtures and ornamental standards (if any), and maintenance. Retail Customer's electric power and energy must be provided by the Retail Customer's REP in accordance with Applicable Legal Authorities and the Company's Tariff.

374

Cost vs. performance ... Gwyn Griffiths email: gxg@noc.soton.ac.uk http://www.noc.soton.ac.uk/OED/gxg/  

E-Print Network [OSTI]

Nexa 1.2 kW PEM fuel cell system from Ballard. Cost ~ 5900 Composite hydrogen storage cylinders e://www.noc.soton.ac.uk/OED/gxg/ Cost vs. performance for fuel cells and batteries within AUVs Gwyn Griffiths National Oceanography typical cost Uses similar method to cost energy from a marinised PEM fuel cell Poses some questions

Griffiths, Gwyn

375

Data:Da10b869-2522-4b0f-b7b6-3127ac40ac6b | Open Energy Information  

Open Energy Info (EERE)

Da10b869-2522-4b0f-b7b6-3127ac40ac6b Da10b869-2522-4b0f-b7b6-3127ac40ac6b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Southwestern Electric Coop Inc (New Mexico) Effective date: 2007/07/01 End date if known: Rate name: Commercial Lighting Service >500 HP Sector: Lighting Description: Source or reference: http://www.swec-coop.org/rates-602-IRR.cfm Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months): Service Voltage Minimum (V): Maximum (V): Character of Service Voltage Category: Phase Wiring: << Previous

376

Data:5799bbde-f3a9-4d53-96ac-552ac0d3bad4 | Open Energy Information  

Open Energy Info (EERE)

bbde-f3a9-4d53-96ac-552ac0d3bad4 bbde-f3a9-4d53-96ac-552ac0d3bad4 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: CenterPoint Energy Effective date: 2013/01/25 End date if known: Rate name: Secondary Service - Greater than 10 kVa, Non-IDR Metered, less than 400 kVa (TC-MGS) - Muni Discount Rate Sector: Commercial Description: Delivery Service will be single-phase, 60 hertz, at a standard secondary voltage. Delivery Service will be metered using Company's standard watt-hour Meter provided for this type of Delivery Service. Any other metering option(s) will be provided at an additional charge and/or will be provided by a Meter Owner other than the Company pursuant to Applicable Legal Authorities. Where Delivery Service of the type desired is not available at the Point of Delivery, additional charges and special contract arrangements may be required prior to Delivery Service being furnished, pursuant to Section 6.1.2.2, Construction Services, in this Tariff.

377

The Nova-Likes Ac Cnc, Rw Tri, Ux Uma and the Nova Dq Her: Common and Different Properties  

Science Journals Connector (OSTI)

An analysis of the main photometric properties of the nova-like variables AC Cnc, RW Tri and UX UMa, and...

E. S. Dmitrienko

1996-01-01T23:59:59.000Z

378

Why Sequence freshwater Actinobacteria belonging to the acI lineage?  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Sequence freshwater Actinobacteria Sequence freshwater Actinobacteria belonging to the acI lineage? The most abundant freshwater bacterioplankton is one that researchers have been unable to grow for study in the lab, away from its natural habitat. The acI Actinobacteria make up as much as 50 percent of the plankton in freshwater lakes and rivers all over the world but researchers don't know exactly what ecological role the bacteria play and how they influence the carbon cycle. Researchers have also noticed that the bacterial population seems to increase when algal blooms or leaf little are present in the water, so they think that bacteria might have enzymes that can break down plant cell walls. Fluorescence in situ hybridisation (FISH) image of acI Actinobacteria in water from Lake Geirneggsee, Austria

379

High-frequency equivalent model of AC motor for electric vehicle drive system  

Science Journals Connector (OSTI)

The application of the motor drive system in electric and hybrid-electric vehicles can lead to a significant increase in electromagnetic compatibility. The AC motor as an important part of motor drive system must be considered. In this paper, a high frequency modelling method of the AC motor is presented. The modelling method consists of deriving the motor model parameters from mathematical resolution of the electrical circuit equations and observation of the variations of the motor impedance with the frequency. All parameters of the proposed models are obtained by differential mode (DM) and common mode (CM) impedance measurement in the frequency domain. The model is verified by impedance measurement of a synchronous motor. The method proposed can be used to obtain a high-frequency equivalent circuit of an AC motor and predict conducted electromagnetic interference in a motor drive system.

Yongming Yang; Hemeng Peng; Quandi Wang

2013-01-01T23:59:59.000Z

380

The ACS LCID Project: Variable Stars in Tucana and LGS3  

E-Print Network [OSTI]

We present preliminary results concerning the search for short-period variable stars in Tucana and LGS3 based on very deep HST/ACS imaging. In the one chip per galaxy we studied so far, a total of 230 and 80 candidates variables were found, respectively. For Tucana, we identified 134 of them as RR Lyrae stars (RRL) pulsating in the fundamental mode (RRab), 51 in the first-overtone mode (RRc), and 37 in both modes simultaneoulsy (RRd), as well as four candidate anomalous Cepheids (AC). In the case of LGS3, we found 45 RRab and 5 RRc, plus three candidates RRd and five candidate AC. The metallicities obtained from the mean period of the RRab are [Fe/H]_{Tuc}=-1.7 and [Fe/H]_{LGS3}=-1.8.

Edouard J. Bernard

2007-05-18T23:59:59.000Z

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

A system for tranmitting low frequency analog signals over ac power lines  

DOE Patents [OSTI]

A system for transmitting low frequency analog signals over ac power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an ac power line. The modulation signal frequency range is selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the ac power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal. 4 figs.

Baker, S.P.; Durall, R.L.; Haynes, H.D.

1987-07-30T23:59:59.000Z

382

Low AC Loss YBCO Coated Conductor Geometry by Direct Inkjet Printing  

SciTech Connect (OSTI)

The second generation (2G) high temperature superconductors (HTS) wire offers potential benefits for many electric power applications, including ones requiring filamentized conductors with low ac loss, such as transformers and fault current limiters. However, the use of 2G wire in these applications requires the development of both novel multi-filamentary conductor designs with lower ac losses and the development of advanced manufacturing technologies that enable the low-cost manufacturing of these filamentized architectures. This Phase I SBIR project focused on testing inkjet printing as a potential low-cost, roll-to-roll manufacturing technique to fabricate potential low ac loss filamentized architectures directly on the 2G template strips.

Rupich, Martin, Dr. [American Superconductor Corporation; Duckworth, Robert, Dr. [Oak Ridge National Laboratory

2009-10-01T23:59:59.000Z

383

System for transmitting low frequency analog signals over AC power lines  

DOE Patents [OSTI]

A system for transmitting low frequency analog signals over AC power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an AC power line. The modulation signal frequency range in selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the AC power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal.

Baker, Steven P. (Powell, TN); Durall, Robert L. (Lenoir City, TN); Haynes, Howard D. (Knoxville, TN)

1989-01-01T23:59:59.000Z

384

Alpha-Decay Studies of the N=127 Isotones Fr214, Ra215, and Ac216  

Science Journals Connector (OSTI)

The study of nuclei which are one neutron removed from the N=126 closed shell has shown that the odd-proton N=127 isotones ? decay from both the ground state and a metastable state whose excitation energy decreases between Bi210 and Ac216. The ?-decay daughters of these nuclei show some correspondence in their energy-level spacings which is due to the coupling of specific single-particle configurations near the N=126 closed shell. New information has been obtained for the ? decay of the 1 - isomer of Fr214 to levels in At210, and for the ? decay of Ac216 to levels in Fr212. The decay scheme of Ac216 is markedly different from that reported by others. An experimental and theoretical study of the ? decay of Ra215 has also been made.

David F. Torgerson and Ronald D. Macfarlane

1970-12-01T23:59:59.000Z

385

The War of the Currents: AC vs. DC Power | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

The War of the Currents: AC vs. DC Power The War of the Currents: AC vs. DC Power The War of the Currents: AC vs. DC Power November 20, 2013 - 3:52pm Addthis Electrical transmission lines cross a snow-covered field in Dallas Dam, Oregon. | Photo courtesy of the Energy Department Flickr page. Electrical transmission lines cross a snow-covered field in Dallas Dam, Oregon. | Photo courtesy of the Energy Department Flickr page. Allison Lantero Allison Lantero Public Affairs Specialist, Office of Public Affairs Tesla vs. Edison Are you on #TeamTesla or #TeamEdison? Vote now on our website for your favorite inventor! Submit questions for Tesla and Edison experts to answer during our live Google+ Hangout on Thursday, Nov. 21, at 12:30 p.m. EST. Read our lists of top facts about Thomas Edison and Nikola Tesla.

386

Aberdeen University Counselling Service Created 19.04.06 www.abdn.ac.uk/counselling Updated 30.08.11  

E-Print Network [OSTI]

Aberdeen University Counselling Service Created 19.04.06 www.abdn.ac.uk/counselling Updated 30 or eliminating them completely? #12;Aberdeen University Counselling Service Created 19.04.06 www.abdn.ac.uk/counselling premises) · Can you devote the time and energy necessary to m

Guerin, Frank

387

Aberdeen University Counselling Service Created 20.04.06 www.abdn.ac.uk/counselling Updated 30.08.11  

E-Print Network [OSTI]

Aberdeen University Counselling Service Created 20.04.06 www.abdn.ac.uk/counselling Updated 30 of success. #12;Aberdeen University Counselling Service Created 20.04.06 www.abdn.ac.uk/counselling for the evening. Take advantage of times when your energy levels are at their highest and do your most demanding

Guerin, Frank

388

Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830  

E-Print Network [OSTI]

PNNL-18896 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Hanford for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Pacific Northwest National Laboratory ............................................. 5 Figure 4. Housing Market Indexes, 1977 to 2008

389

Electrospray mass spectrometry of NeuAc oligomers associated with the C fragment of the tetanus toxin  

SciTech Connect (OSTI)

The Clostridial neurotoxins, botulinum and tetanus, gain entry into neuronal cells by protein recognition involving cell specific binding sites. The sialic or N-acetylneuraminic acid (NeuAc) residues of gangliosides attached to the surface of motor neurons are the suspected recognition and interaction points with Clostridial neurotoxins, although not necessarily the only ones. We have used electrospray ionization mass spectrometry (ESIMS) to examine formation of complexes between the tetanus toxin C fragment, or targeting domain, and carbohydrates containing NeuAc groups to determine how NeuAc residues contribute to ganglioside binding. ESI-MS was used to rapidly and efficiently measure dissociation constants for a number of related NeuAc-containing carbohydrates and NeuAc oligomers, information that has helped identify the structural features of gangliosides that determine their binding to tetanus toxin. The strength of the interactions between the C fragment and (NeuAc){sub n}, are consistent with the topography of the targeting domain of tetanus toxin and the nature of its carbohydrate binding sites. The results suggest that the targeting domain of tetanus toxin contains two binding sites that can accommodate NeuAc (or a dimer). This study also shows that NeuAc must play an important role in ganglioside binding and molecular recognition, a process critical for normal cell function and one frequently exploited by toxins, bacteria and viruses to facilitate their entrance into cells.

Prieto, M C; Whittal, R M; Baldwin, M A; Burlingame, A L; Balhorn, R

2005-04-03T23:59:59.000Z

390

Theoretical prediction of fast 3D AC electro-osmotic pumps Martin Z. Bazant* and Yuxing Ben  

E-Print Network [OSTI]

Theoretical prediction of fast 3D AC electro-osmotic pumps Martin Z. Bazant* and Yuxing Ben September 2006 DOI: 10.1039/b608092h AC electro-osmotic (ACEO) pumps in microfluidics currently involve. In this paper, we present some new design principles for periodic 3D ACEO pumps, such as the ``fluid conveyor

Bazant, Martin Z.

391

Design principle for improved three-dimensional ac electro-osmotic pumps Damian Burch and Martin Z. Bazant*  

E-Print Network [OSTI]

Design principle for improved three-dimensional ac electro-osmotic pumps Damian Burch and Martin Z-dimensional 3D ac electro-osmotic ACEO pumps have recently been developed that are much faster and more robust pumps are crucial components of lab-on-a- chip systems. There is growing interest in exploiting various

Bazant, Martin Z.

392

The dependence of AC loss characteristics on the spacing between strands in YBCO Roebel  

Science Journals Connector (OSTI)

Transport AC loss in a short length of 9/2 YBCO Roebel cable, (i.e.with 9 ? 2mm width strands), with 0.25mm spacers between the strands is measured. The frequency varies from 59 to 354Hz. The result is compared with the loss for a cable without spacers between the strands. Transport AC loss is decreased by the presence of the spacers. The AC loss reduction due to the extra spacing is more significant when the amplitude of the cable current is small compared to the cable Ic. The losses in the cable with spacers normalized by the square of the cable currents plotted against It/Ic approximately agree with those in a cable without spacers. Electromagnetic modelling was carried out for 9/2 and 8/2 cables, modelled as parallel stacks, to assist in understanding the above experimental results. The 8/2 configuration allows the greater use of symmetry to speed computations. Reasonable agreement between the numerical results and the measured results was obtained. This supports suggestions made in previous publications that the transport AC loss in a Roebel cable is roughly equivalent to the loss in two parallel stacks carrying the same current in each tape. The electromagnetic analysis in the 8/2 stacks shows the flux lines are more perpendicular to the strand face when the vertical space between strands is smaller, and this leads to a larger induced electrical field and larger AC loss. At small current amplitudes, the modelling shows the spacing has a strong effect on the AC loss in the surfaced part of the strands.

Zhenan Jiang; K P Thakur; Mike Staines; R A Badcock; N J Long; R G Buckley; A D Caplin; Naoyuki Amemiya

2011-01-01T23:59:59.000Z

393

MSc Dissertation (NURM112) -Student Enrolment form Full Time Students Module Leader: Ms Mary Kelly (mary.kelly@surrey.ac.uk)  

E-Print Network [OSTI]

Kelly (mary.kelly@surrey.ac.uk) 1. Programme Registration Year 2. Full Name 3. University Registration

Doran, Simon J.

394

MSc Dissertation (NURM112) -Student Enrolment form Part Time Students Module Leader: Ms Mary Kelly (mary.kelly@surrey.ac.uk)  

E-Print Network [OSTI]

Kelly (mary.kelly@surrey.ac.uk) 1. Programme Registration Year 2. Full Name 3. University Registration

Doran, Simon J.

395

Subscriber access provided by -Access paid by the | UC Davis Libraries ACS Chemical Biology is published by the American Chemical Society. 1155 Sixteenth  

E-Print Network [OSTI]

A. Beal ACS Chem. Biol., Just Accepted Manuscript · DOI: 10.1021/cb300692k · Publication Date (Web

Beal, Peter A.

396

Application of the AC Commutator Machine in Wind Energy Conversion Systems  

E-Print Network [OSTI]

APPLICATION OF THE AC OOMM3TATOR MACHINE IN WIND ENERGY CONVKGION SYSTB3S A Thesis By SAMI GF33RGES EL-Jhl'3OUS Submitted to the Graduate College of Twas AW University in partial fulfillment of the requirement for the degree of MASTER... Application of the AC Comnutator Nachine in Wind Energy Conversion Systems. (Nay 1981) Semi Georges El-Jasnus, B. A. Nathenatics, Texas ASN University; Chairman of Advisory Comnittee: Dr. A. K. Ayoub The thesis investigates the tectudcal feasibility...

El-Jamous, Sami Georges

1981-01-01T23:59:59.000Z

397

Levels in 221Fr fed by the ? decay of 225Ac  

Science Journals Connector (OSTI)

The ? decay of 225Ac to 221Fr was reinvestigated by ?-ray spectroscopic studies with HPGe detectors and 225Ac sources purified using continuous elution processes. Energies and intensities of about 120 ?-ray transitions were measured. Among these, 40 are reported for the first time. A 221Fr level scheme with 46 excited states and 124 transitions is proposed. The level structure is described in terms of a reflection asymmetric structure with parity doublet bands K?=1/2, 3/2, 5/2, and 3/2 in order of increasing energy. Both strong and intermediate coupling models have been shown to be in good agreement with the experimental data.

G. Ardisson; J. Gasparro; V. Barci; R. K. Sheline

2000-11-09T23:59:59.000Z

398

A robust coordinated control scheme for HVDC transmission with parallel AC systems  

SciTech Connect (OSTI)

This paper introduces a practical control philosophy for HVDC transmission in parallel operation to an AC system with particular emphasis on coordination of both transient and dynamic stability. Systematic development of the control scheme on the basis of on-line identification, optimal control and rule-based bang-optimal coordination principles is presented. Verification tests of the scheme on a physical HVDC/AC system simulator show that the simple control computer algorithm is practical and robust. The controller can successfully distinguish between different system fault severities and adapts its output signals to provide maximum synchronizing torque and ensure optimal damping of power oscillations.

To, K.W.V.; David, A.K. (Hong Kong Polytechnic (Hong Kong). Dept. of Electrical Engineering); Hammad, A.E. (N.E. Swiss Power Co., Baden (Switzerland))

1994-07-01T23:59:59.000Z

399

Data:Fbe8ac6d-b14a-4115-887a-c083d118bb18 | Open Energy Information  

Open Energy Info (EERE)

b14a-4115-887a-c083d118bb18 b14a-4115-887a-c083d118bb18 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Jackson Electric Member Corp Effective date: End date if known: Rate name: Commercial General Service All Electric Three Phase Sector: Commercial Description: Source or reference: http://www.jacksonemc.com/business-manage-my-account-commercial-rates-options/schedules/general-service-all-electric Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months): Service Voltage Minimum (V): Maximum (V): Character of Service

400

Copyright 1999 The Association of Universities for Research in Astronomy, Inc. All Rights Reserved. Instrument Science Report ACS 2002-10  

E-Print Network [OSTI]

. Instrument Science Report ACS 2002-10 ACS software tool development W.B. Sparks, W.J. Hack, R.N. Hook, A pipeline operations are described in ACS ISRs 99-03 (Hack), 99-04 (Mutchler et al) and 99-08 (Hack

Sirianni, Marco

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Data:9d390ac8-e291-4feb-a7cf-ac92814a88b4 | Open Energy Information  

Open Energy Info (EERE)

90ac8-e291-4feb-a7cf-ac92814a88b4 90ac8-e291-4feb-a7cf-ac92814a88b4 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Prairie Land Electric Coop Inc Effective date: 2010/01/14 End date if known: Rate name: CONTROLLED PRIVATE AREA LIGHTING: MV 1000W Flood Sector: Lighting Description: To any customer for lighting of outdoor areas on a dusk to dawn, photo-controlled, unmetered basis from Cooperative's existing distribution system. No additional lamps will be installed under this schedule after the effective date of September 26, 1994. Annual Rate/Unit= $436.56 1) For each additional standard distribution pole, not longer than thirty-five (35) feet, required for such area lighting supply is $1.42 per month. 2) For each one hundred (100) feet of overhead secondary circuit required is $ .53 per month. 3) Steel standards with maximum mounting height of thirty (30) feet and of the same type as used in street lighting will be furnished upon request provided the customer will be responsible for the placement of the concrete base and anchor bolts at the time of the installation and also for their removal upon termination of the leased lighting agreement. Monthly rental charge for each standard is $6.73. 4) Customer will be responsible for any underground circuits or special wiring.

402

www.exeter.ac.uk/inspiring-science Impact of Climate Change on Urban Flooding  

E-Print Network [OSTI]

www.exeter.ac.uk/inspiring-science Impact of Climate Change on Urban Flooding: a fairy taleMatiCs and PhysiCal sCienCes 2011ceMPS45 Dr Ole Mark is a specialist in climate change and urban water systems-years' experience in both developed and developing countries. Dr Mark is a key partner in the CORFU

Mumby, Peter J.

403

AC 2010-1901: NASA SENIOR DESIGN: SYSTEMS ENGINEERING AND REUSABLE AVIONICS  

E-Print Network [OSTI]

AC 2010-1901: NASA SENIOR DESIGN: SYSTEMS ENGINEERING AND REUSABLE AVIONICS James Conrad intelligence, and engineering education. © American Society for Engineering Education, 2010 #12;NASA Senior so that the students were able to meet nearly all of the project requirements. NASA Faculty Fellow

Conrad, James M.

404

Function Block Diagrams * {ekjee, jbyoo, suhyun, cha}@dependable.kaist.ac.kr  

E-Print Network [OSTI]

}@dependable.kaist.ac.kr : FBD(Function Block Diagram) FBD . PLC FBD C . FBD . FBD Center(ITRC). RLL(Relay Ladder Logic) , . PLC(Programmable Logic Controller) [2] , LD(Ladder Diagram) FBD(Function Block Diagram) PLC . PLC . PLC

405

Comparing Web Services with Other Software Components y.yu@open.ac.uk  

E-Print Network [OSTI]

- 1 - Comparing Web Services with Other Software Components Yijun Yu y.yu@open.ac.uk Computing to be developed. As a kind of software components, web service technology has flourished and attracted a flurry of research activities. Despite the vast amount of research on mechanisms of web services, there have been

Lu, Jianguo

406

AC 2010-863: POSTER, INCORPORATING ENGINEERING DESIGN INTO ELEMENTARY SCHOOL SCIENCE CURRICULA  

E-Print Network [OSTI]

AC 2010-863: POSTER, INCORPORATING ENGINEERING DESIGN INTO ELEMENTARY SCHOOL SCIENCE CURRICULA Academy of Sciences, which reports that the number of students who have had formal engineering education Marulcu, Boston College © American Society for Engineering Education, 2010 #12;Incorporating Engineering

407

The AC Stark E#ect, Time--Dependent Born--Oppenheimer Approximation, and  

E-Print Network [OSTI]

The AC Stark E#ect, Time--Dependent Born--Oppenheimer Approximation, and Franck--Condon Factors by a classical oscillatory electric field, and we employ the Born--Oppenheimer approximation for the molecule. We-- Condon factors that we compute explicitly to leading order in the Born--Oppenheimer parameter. We also

Rousse, Vidian

408

The AC Stark E ect, Time{Dependent Born{Oppenheimer Approximation, and  

E-Print Network [OSTI]

The AC Stark E#11;ect, Time{Dependent Born{Oppenheimer Approximation, and Franck{Condon Factors the laser pulse by a classical oscillatory electric #12;eld, and we employ the Born{Oppenheimer. These amplitudes contain Franck{ Condon factors that we compute explicitly to leading order in the Born{Oppenheimer

Hagedorn, George A.

409

Zelftest chemie voor 1 Ba Biologie Voor meer informatie: contacteer csb.etterbeek@vub.ac.be  

E-Print Network [OSTI]

Zelftest chemie voor 1 Ba Biologie Voor meer informatie: contacteer csb overzicht van de verwachte voorkennis chemie. 1. Elementaire chemie en chemisch rekenen 1.1 Grootheden en, keukenzout #12;Zelftest chemie voor 1 Ba Biologie Voor meer informatie: contacteer csb.etterbeek@vub.ac.be 1

Einmahl, Uwe

410

Stability analysis of multi-phase AC arc discharge for in-flight glass melting  

Science Journals Connector (OSTI)

A stable multi-phase AC arc was generated to by transformers at a commercial electric system. The arc discharge behavior and the stability were investigated by the high-speed video camera observation synchronized with the voltage waveform analysis. The effect of the number of phase and the flaming gas addition into the arc region on the arc behavior and the arc stability were studied. Results showed that the re-ignition occurred between adjacent electrodes periodically. Two kinds of the stability analysis methods were introduced. The estimated fluctuation degree showed that an increase of the number of the phase leads to the stable multi-phase AC arc. The deviation of the arc voltage from the average arc voltage was estimated to evaluate the uniformity of the multi-phase AC arc. Although an addition of the oxygen flame into the arc region leads to lower uniformity, the modification of the electrode position can improve the uniformity of the multi-phase AC arc.

Manabu Tanaka; Yosuke Tsuruoka; Yaping Liu; Tsugio Matsuura; Takayuki Watanabe

2011-01-01T23:59:59.000Z

411

Effect of dissipation on the ac response of a resonant-tunneling diode  

Science Journals Connector (OSTI)

The effect of dissipation on the ac linear response of a resonant-tunneling diode is investigated theoretically by applying two well-known models. (i) The featureless phase-breaking model is applied to study the acoustic-phonon scattering, where we show that the phase-breaking process has no significant effect on the ac conductance in the high-temperature limit; phase breaking does have an influence at low temperatures, and we also discuss the characteristic time at zero temperature. (ii) The independent boson model is applied to describe the LO-phonon scattering, where we find a shift for the ac-conductance peak due to the renormalizing effect of the electron LO-phonon interaction on the resonant level and compare the line shape of the renormalized response function with that from the acoustic-phonon scattering. We also study the possibility of probing the emission of LO phonons in the ac response in the limit of zero temperature, and discuss the relevant experimental condition. 1996 The American Physical Society.

Xin-Qi Li

1996-11-15T23:59:59.000Z

412

Optimal Selection of AC Cables for Large Scale Offshore Wind Farms  

E-Print Network [OSTI]

Optimal Selection of AC Cables for Large Scale Offshore Wind Farms Peng Hou, Weihao Hu, Zhe Chen@et.aau.dk, whu@iet.aau.dk, zch@iet.aau.dk Abstract--The investment of large scale offshore wind farms is high the operational requirements of the offshore wind farms and the connected power systems. In this paper, a new cost

Hu, Weihao

413

Library Information Literacy Section literacy@lib.kobe-u.ac.jp  

E-Print Network [OSTI]

library (P. 4) Available in Kobe University libraries Search the Kobe University online catalog OPAC Kobe. Online Public Access Catalog (OPAC) http://lib.kobe-u.ac.jp/www/modules/eng/ New books list and other Univ. Library 3. How to read the search result of OPAC Bibliographic information What does the call

Banbara, Mutsunori

414

PHYSICAL REVIEW E 86, 036314 (2012) ac electric fields drive steady flows in flames  

E-Print Network [OSTI]

PHYSICAL REVIEW E 86, 036314 (2012) ac electric fields drive steady flows in flames Aaron M. Drews June 2012; published 20 September 2012) We show that time-oscillating electric fields applied-averaged force that drives the steady flows observed experimentally. A quantitative model describes the response

Heller, Eric

415

Comparison of AC drives for electric vehicles -- A report on experts` opinion survey  

SciTech Connect (OSTI)

It is recognized that wide applications of electric vehicles (EVs) will bring tremendous social, economical and ecological benefits. With the growing interests in electric vehicles, much effort is demanded for the development of efficient, reliable and economical AC drives` for EV propulsion purpose. Both induction motor (IM) drives and permanent magnet brushless DC motor (BDCM) drives have been applied to EVs. Switched reluctance motor (SRM) drives have been proposed as an alternative for EV propulsion. In order to assess the suitability of IM, BDCM and SRM drives for EV applications and to provide a technical support for the development and selection of future EV propulsion systems, the existing EV AC propulsion drives were compared, and a survey of experts` opinions was conducted. Comparison of the three AC drives was made on a relative and a quantitative basis using the survey questionnaires. According to the majority of the experts, induction motor drives are best suited for EV propulsion purpose, due to their low cost, high reliability, high speed, established converter and manufacturing technology, low torque ripple/noise and absence of position sensors. BDCM drives feature compactness, low weight and high efficiency and therefore provide an alternative for EV propulsion. The experts regard insulated gate bipolar transistors (IGBTs) as the most suited power semiconductor devices for AC drive converters at the present stage. 7 refs.

Chang, L. [New Brunswick Univ., Fredericton, New Brunswick (Canada). Dept. of Electrical Engineering] [New Brunswick Univ., Fredericton, New Brunswick (Canada). Dept. of Electrical Engineering

1994-08-01T23:59:59.000Z

416

www.arts.canterbury.ac.nz/internships Project Title: Health, History and Digital  

E-Print Network [OSTI]

project on the history of unfree labour in the Pacific. The intern will link the database to other onlinewww.arts.canterbury.ac.nz/internships Project Title: Health, History and Digital Humanities: The project explores the health history of indentured labourers in Fiji. The intern will digitise microfilm

Hickman, Mark

417

Time-Resolved Magnetic Flux and AC-Current Distributions in Superconducting YBCO Thin Films and  

E-Print Network [OSTI]

Time-Resolved Magnetic Flux and AC-Current Distributions in Superconducting YBCO Thin Films and Multifilament Ran Yang College of William & Mary, Department of Applied Science, 2008 Field: Surface and Interface Science, Degree: Ph.D. Advisor: Gunter Luepke, Associate Professor of Applied Science Abstract

Shaw, Leah B.

418

Coated conductor arrangement for reduced AC losses in a resistive-type superconducting  

Science Journals Connector (OSTI)

The basic element of a resistive superconducting fault current limiter (FCL) can consist of coated conductor tape exceeding a few meters in length and compacted into a cryogenic envelope. This paper is focused on optimizing the arrangement of coated conductors with a non-magnetic substrate for a resistive superconducting FCL. Several configurations have been tested experimentally and theoretically. Two low-loss arrangements have been identified, both utilizing the bifilar configuration, i.e.the currents in two adjacent tapes are identical in amplitude but opposite in direction. The separation between two adjacent tapes s varied from 0.07 up to 2.10mm. For the lowest examined separation s the AC transport loss of the straight bifilar model decreased by more than one order with respect to the AC transport loss in the single-tape configuration. Further AC loss decrease is achieved when the pair of tapes carrying opposite currents forms a flat pancake coil. We developed a numerical model in order to analyze the influence of distance between adjacent tapes. To achieve agreement between experimental and numerical results it was necessary to incorporate a lateral distribution of critical current density in the tape. The remaining differences between the results of experiment and calculation can be explained by analysis of experimental imperfections. Finally we suggest an empirical fit for the prediction of AC loss of a practical superconducting fault current limiter.

J ouc; F Gmry; M Vojen?iak

2012-01-01T23:59:59.000Z

419

Contract Number: DE-AC05-76RL01830 Modification M962  

E-Print Network [OSTI]

Contract Number: DE-AC05-76RL01830 Modification M962 PART III ­ List of Documents, Exhibits and Other Attachments Section J Appendix C Subcontracting Plan for Socioeconomic Programs J-C-i #12;Contract, 2002, for the entire Contract period associated with this Contract. However, annual goals shall

420

Contract No. DE-AC02-09CH11466 CONTRACT CLAUSES  

E-Print Network [OSTI]

Contract No. DE-AC02-09CH11466 Section I M110 I-i PART II SECTION I CONTRACT CLAUSES TABLE) .........................................................................................24 Clause I.18 - Far 52.215-8 Order Of Precedence - Uniform Contract Format (Oct 1997

Princeton Plasma Physics Laboratory

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Contract Number: DE-AC05-76RL01830 Modification M705  

E-Print Network [OSTI]

Contract Number: DE-AC05-76RL01830 Modification M705 Part III - List of Documents, Exhibits be designated: a. Battelle Memorial Institute, PNW Division -Contract b. Battelle Memorial Institute, PNW Division- Salary c. Battelle Memorial Institute, PNW Division -Controlled Disbursement Contract d. Battelle

422

Contract No. DE-AC02-09CH11466 SPECIAL CONTRACT REQUIREMENTS  

E-Print Network [OSTI]

Contract No. DE-AC02-09CH11466 Section H M152 H-i PART I SECTION H SPECIAL CONTRACT REQUIREMENTS .................................................................................................. 8 CLAUSE H.11 - SERVICE CONTRACT ACT OF 1965 (41 U.S.C. 351) ....................................................... 9 CLAUSE H.12 - WALSH-HEALY PUBLIC CONTRACTS ACT (OCT 2010) [M069 ­ 6

Princeton Plasma Physics Laboratory

423

Contract Number: DE-AC05-76RL01830 Modification M963  

E-Print Network [OSTI]

Contract Number: DE-AC05-76RL01830 Modification M963 Part II ­ Contract Clauses Section I Contract) .............................................................19 I­13 FAR 52.215-8 Order of Precedence -- Uniform Contract Format (Oct 1997) .................20 I)...........................................................................36 I­21 FAR 52.222-4 Contract Work Hours and Safety Standards Act -- Overtime Compensation (July 2005

424

Contract Number: DE-AC05-76RL01830 Modification M412  

E-Print Network [OSTI]

Contract Number: DE-AC05-76RL01830 Modification M412 PNNL Contract Table of Contents SECTION A: Contract Form SECTION B: Supplies or Services and Prices/Costs B-1: Designation of Work and Facilities B-2: Contract Administration Data G-1: Head of Contracting Activity (HCA), Contracting Officer (CO

425

Strongly nonlinear dynamics of electrolytes in large ac voltages Laurits Hjgaard Olesen,1,2  

E-Print Network [OSTI]

the results have been developed for over a century 1 . Current applications include energy storage; published 2 July 2010 We study the response of a model microelectrochemical cell to a large ac voltage of frequency comparable to the inverse cell relaxation time. To bring out the basic physics, we consider

426

Techniques for energy conservation in ac motor-driven systems. Final report  

SciTech Connect (OSTI)

Techniques for energy conservation of reducing losses in ac motor-driven systems proposed by the technical community in response to surging cost of energy are evaluated and compared. Report objectives are to provide better understanding of underlying principles and to evaluate technical and economic viability of these techniques for various applications. An important aspect considered is the impact on electric utility system in terms of harmonics, power factor of operation, and Electro-Magnetic Interference (EMI). The techniques evaluated are: NASA Power Factor Controller, a simple device for reducing power losses in lightly loaded ac motors; wanlass motor modification, a scheme of reconnecting motor windings with capacitors in series, with the intention of improving the motor efficiencies under all loading conditions; conventional variable frequency solid-state inverters which can control the speed of ac motors by producing adjustable frequency ac voltage, with a significant potential for energy conservation in pumps and air-handling systems; and other variable frequency drives and schemes including cycloconverters, slip-recovery scheme, Exxon Alternating Current Synthesizer, Venturini conversion technique, permanent magnet synchronous motors, and a device called the Phase-Liner. The impact of rapid growth in semiconductors and magnetic materials technologies is also considered.

Mohan, N.

1981-09-01T23:59:59.000Z

427

Seoul National University http://bp.snu.ac.kr The Role of Carbon Incorporation in  

E-Print Network [OSTI]

O2 · Hydrothermal followed by carbonization at 500°C J. Phys. Chem. C 113, 20504 (2009). J. PhysSeoul National University http://bp.snu.ac.kr The Role of Carbon Incorporation in SnO2 of cracks during cycling Sn-Based Oxide Li Metal Carbon-Coated SnO2 #12;Seoul National University http

Park, Byungwoo

428

AC 2010-567: THE IMPORTANCE OF PROBLEM INTERPRETATION FOR ENGINEERING STUDENTS  

E-Print Network [OSTI]

include the cognitive processes of engineering design, gender issues in engineering, and creative selfAC 2010-567: THE IMPORTANCE OF PROBLEM INTERPRETATION FOR ENGINEERING STUDENTS Gay Lemons, Tufts University Gay Lemons, Ph.D., is a post-doctoral research associate in Engineering Education at Tufts

429

http://stir.ac.uk/4x Why study Retail Marketing?  

E-Print Network [OSTI]

http://stir.ac.uk/4x BA(Hons) Retail Marketing #12;Why study Retail Marketing? Retailers lead marketing: Retailers have taken over marketing leadership from manufacturers. Retailers lead innovation and change: Sophisticated customer relationship programmes, multi-channel promotional and marketing

Little, Tony

430

Chaos, Fractals and Bifurcations Lecturer: Chris King king@math.auckland.ac.nz, Ph 88818  

E-Print Network [OSTI]

-locking and the devil's staircase. Structural stability, bifurcation theory, Morse-smale systems homoclinic pointsMATHS 745 Chaos, Fractals and Bifurcations Lecturer: Chris King king@math.auckland.ac.nz, Ph 88818 Chaos, fractals and bifurcation, and their application to wide areas including commerce, medicine

King, Chris

431

(OSCAR API ver. 2.0) http://www.kasahara.cs.waseda.ac.jp/  

E-Print Network [OSTI]

(OSCAR API ver. 2.0) http://www.kasahara.cs.waseda.ac.jp/ kasahara@waseda.jp Tel. 03 APIOSCAR OSCAR OSCAR OSCAR Many-core Chip , , #12;OSCAR API v2.0 · NEDO20081114OSCAR API ver.1.0 22CFortran2 CFortran DMAC OSCAR API ver.2.0OSCAR APIOSCAR API2012425http

Kasahara, Hironori

432

Comparison of Two Autonomous AC-DC Converters for Piezoelectric Energy Scavenging Systems  

E-Print Network [OSTI]

, on the other, given the very low energetic content associated to environmental energy, the interface circuit- 1 - Comparison of Two Autonomous AC-DC Converters for Piezoelectric Energy Scavenging Systems E Cornaredo, Milan, Italy Abstract - Piezoelectric Energy Scavenging Systems (PESS) are used to convert

Boyer, Edmond

433

Ac-conductivity and electromagnetic energy absorption for the Anderson model in linear response theory  

E-Print Network [OSTI]

We continue our study of the ac-conductivity in linear response theory for the Anderson model using the conductivity measure. We establish further properties of the conductivity measure, including nontriviality at nonzero temperature, the high temperature limit, and asymptotics with respect to the disorder. We also calculate the electromagnetic energy absorption in linear response theory in terms of the conductivity measure.

Abel Klein; Peter Mller

2014-03-03T23:59:59.000Z

434

AC conductivity of nanoporous metal-oxide photoanodes for solar energy conversion  

E-Print Network [OSTI]

AC conductivity of nanoporous metal-oxide photoanodes for solar energy conversion Steven J. Konezny% solar-to-electric energy conversion efficiency) exploited the large surface area of nanoporous thin of nanoporous thin films without increasing the recombination rate. To ensure efficient charge carrier

Konezny, Steven J.

435

Two dimensional thermoelectric platforms for thermocapillary droplet Man-Chi Liu,ac  

E-Print Network [OSTI]

the cooling function relies on the natural conduction and/or convection. A thermoelectric (TE) chipTwo dimensional thermoelectric platforms for thermocapillary droplet actuation Man-Chi Liu,ac Jin be driven to the cooler regions via surface tension modulation by varying the temperature. The usual method

Lin, Pei-Chun

436

Design and Implementation of a High-Fidelity AC Metering Network  

E-Print Network [OSTI]

in residential and commercial build- ings represent a significant fraction of total energy ex- penditure and evaluation of ACme, a wireless sensor and actuator net- work for monitoring AC energy usage and controlling different kind of application­ high fidelity, building-wide, electricity monitoring. Electricity usage

Dutta, Prabal

437

AC spectrum for a class of random operators at small disorder  

E-Print Network [OSTI]

of the theory. There is a rich literature on the a.c. spectrum for decaying random po- tentials on 2 (Z was shown by Klein [14] and by Froese-Hasler-Spitzer [9]. In 2, a slightly modified model with decaying

438

Planar microresonators for EPR experiments R. Narkowicz a,c,*, D. Suter a  

E-Print Network [OSTI]

Planar microresonators for EPR experiments R. Narkowicz a,c,*, D. Suter a , R. Stonies b 2005 Available online 6 June 2005 Abstract EPR resonators on the basis of standing-wave cavities than the wavelength. We discuss the design and evaluation of EPR resonators on the basis of planar

Suter, Dieter

439

Electrochimica Acta 51 (2005) 943951 Tin oxide nanosensor fabrication using AC dielectrophoretic  

E-Print Network [OSTI]

into the microchannel. An alternating (AC) voltage of 9.8 V peak to peak, with variable frequency, was applied between, Room 321 Love Building, 771, Ferst Drive, Atlanta, GA 30332, USA b School of Materials Science a Maxwell­ Wagner interfacial polarization at a frequency determined by the relationship between the complex

Wang, Zhong L.

440

A direct AC-to-DC converter topology with high-frequency isolation  

E-Print Network [OSTI]

-to-ac converter eliminating the acto-dc rectification stage, power factor correction boost stage, and dc-dc converter stage present in the conventional system. The output of the high-frequency isolation transformer is rectified and processed via a filtering stage...

Sulistyono, Widodo

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Chemistry -Bachelor of Science (SCH2UG) Total Credits Required: 128 Chemistry/Biochemistry -ACS Certified  

E-Print Network [OSTI]

Chemistry - Bachelor of Science (SCH2UG) Total Credits Required: 128 Chemistry/Biochemistry - ACS credits Course Credits Course Credits CH1150 University Chemistry I AND 3 BL1040 Principles of Biology 4 CH1151 University Chemistry Lab 1 AND 1 BL4820 Biochem Techniques I 2 CH1153 University Chemistry

442

Chemistry -Bachelor of Science (SCH5UG) Total Credits Required: 128 Chemistry/Environmental -ACS Certified  

E-Print Network [OSTI]

Chemistry - Bachelor of Science (SCH5UG) Total Credits Required: 128 Chemistry/Environmental - ACS credits Course Credits Course Credits CH1150 University Chemistry I AND 3 BL1040 Principles of Biology 4 CH1151 University Chemistry Lab 1 AND 1 BL3310 Environmental Microbiology 3 CH1153 University

443

Chemistry -Bachelor of Science (SCHUG) Total Credits Required: 128 Chemistry -ACS Certified  

E-Print Network [OSTI]

Chemistry - Bachelor of Science (SCHUG) Total Credits Required: 128 Chemistry - ACS Certified Major of the following courses Course Credits Course Credits CH1150 University Chemistry I AND 3 CH4110 Pharmaceutical Chemistry: Drug Action 3 CH1151 University Chemistry Lab 1 AND 1 CH4120 Pharmaceutical Chemistry: Drug

444

Chemistry -Bachelor of Science (SCH1UG) Total Credits Required: 128 Chemistry/Polymers -ACS Certified  

E-Print Network [OSTI]

Chemistry - Bachelor of Science (SCH1UG) Total Credits Required: 128 Chemistry/Polymers - ACS credits Course Credits Course Credits CH1150 University Chemistry I AND 3 CH4610 Intro to Polymer Science 3 CH1151 University Chemistry Lab 1 AND 1 CH4620 Polymer Chemistry 3 CH1153 University Chemistry

445

An empirical study of the economies of scale in AC transmission line construction costs  

E-Print Network [OSTI]

1 An empirical study of the economies of scale in AC transmission line construction costs Krishnan the interconnection (Western, ERCOT, Eastern) in which the transmission was built, and · the capacity of the line. We the change in "Available Transmission Capability" (ATC) [4] between the cases of having the line in and out

Baldick, Ross

446

Nano-diamonds in the Universe A.C. Andersen,1  

E-Print Network [OSTI]

Nano-diamonds in the Universe A.C. Andersen,1 H. Mutschke,2 L. Binette3 , S. Höfner4 1 NORDITA, SE-75120 Uppsala Sweden The first direct evidence for nano-diamonds in space came from meteorites. Laboratory analyses on fine-grained diamond residues from primitive meteorites have shown that nano- diamonds

Andersen, Anja C.

447

AC loss characteristics of superconducting power transmission cables: gap effect and  

Science Journals Connector (OSTI)

Four groups of superconducting power transmission cables composed of coated conductors with 4.0mm width and 2m superconductor thickness have been designed, including mono-layer, two-layer, four-layer and six-layer cables. In each group, three types of cables have been constructed with gaps of different size between adjacent coated conductors, which are classified into small gap, medium gap and large gap. Moreover, different lateral critical current density (Jc) distributions, specifically a uniform distribution and a trapezoidal distribution with a sloping shoulder, have been assumed while calculating the AC losses of these cables numerically by using a one-dimensional FEM model. Numerical results show that AC losses in mono-layer cables are significantly influenced by gaps between coated conductors as well as lateral Jc distribution, while cables with many layers are hardly affected by them. This proves that small gaps between coated conductors are not absolutely essential to reduce AC losses in multi-layer cables, and a sloping shoulder of the Jc distribution is more allowable in multi-layer cables than in mono-layer cables. The AC loss distributions among layers in six-layer cables are presented and the reasons for different influences of the gap as well as the lateral Jc distribution in mono-layer and multi-layer cables are discussed.

Quan Li; Naoyuki Amemiya; Katsutoku Takeuchi; Taketsune Nakamura; Noboru Fujiwara

2010-01-01T23:59:59.000Z

448

AC Loss of Ripple Current in Superconducting DC Power Transmission Cable  

Science Journals Connector (OSTI)

Abstract As a method of largely reducing the transmission loss in the electric power grid, superconducting direct current (DC) power transmission cable has been investigated. Using superconducting DC power transmission cables, large amounts of current and energy can be transferred compared to conventional copper cables. In this case, an alternating current (AC) is converted to DC and superposed AC which is known as ripple current, and the energy loss by the ripple current is generated. Therefore it is desired to estimate the energy loss density for the case of DC current and superposed AC current for a design of DC transmission cable system. In this study, the hysteresis loss for DC current of 2 kA rectified from 60Hz alternating current is calculated using the Bean model, and coupling loss was also estimated. The diameter of the cable was 40mm. The ripple currents generated by multi-pulse rectifiers, 6-pulse, 12-pulse, and 24-pulse were considered. It is found that the total AC loss including the hysteresis loss and the coupling loss is considerably smaller than the supposed heat loss of 0.5W/m which is obtained with a newly developed cable.

K. Yoshitomi; E.S. Otabe; V.S. Vyatkin; M. Kiuchi; T. Matsushita; M. Hamabe; S. Yamaguchi; R. Inada

2014-01-01T23:59:59.000Z

449

Study of parallel AC and DC electrical distribution in the all-electric ship  

Science Journals Connector (OSTI)

Medium-voltage DC electrical distribution is envisioned as a possible system for the warship of the future, bringing numerous advantages including a very power-dense architecture. This system takes the AC power produced by generators, immediately rectifies ... Keywords: MVDC, electric-drive ship, electrical distribution

Julie S. Chalfant; Chryssostomos Chryssostomidis; Matthew G. Angle

2010-07-01T23:59:59.000Z

450

Research Student Handbook www.leeds.ac.uk/rsa/handbooks.html  

E-Print Network [OSTI]

that the information contained in this Handbook is accurate it does not accept liability for any inaccuraciesResearch Student Handbook 2011-2012 www.leeds.ac.uk/rsa/handbooks.html This Handbook should be read;Research Student Handbook 2011-2012 Important This Handbook was published in August 2011. Whilst

Haase, Markus

451

Use of the Transposon Ac as a Gene-Searching Engine in the Maize Genome  

Science Journals Connector (OSTI)

...an excellent gene-searching engine in the highly repetitive maize...The Mutants of Maize. (Cold Spring Harbor, NY: Cold Spring Harbor Laboratory Press). Parinov...transposon Ac as a gene-searching engine in the maize genome. | We show...

Matthew Cowperthwaite; Wonkeun Park; Zhennan Xu; Xianghe Yan; Steven C. Maurais; Hugo K. Dooner

2002-03-08T23:59:59.000Z

452

AC-loss considerations of a pulse SMES for an accelerator  

Science Journals Connector (OSTI)

In particle accelerators quasi-DC superconducting magnets are used to keep particles in desired tracks. The needed rapid field variations of these high energy magnets require large energy bursts. If these bursts are taken from and fed back to the utility grid, its voltage is distorted and the quality of the electricity degrades. In addition, these bursts may decrease operation life time of generators and extra arrangements may be required by the electricity producers. Thus, an energy storage is an essential component for a cost-effective particle accelerator. Flywheels, capacitors and superconducting magnetic energy storage (SMES) are possible options for these relatively large and high power energy storages. Here we concentrate on AC-loss of a pulse SMES aiming to demonstrate the feasibility of NbTi SMES in a particle accelerator. The designing of a SMES requires highly reliable AC-loss simulations. In this paper, calorimetric AC-loss measurements of a NbTi magnet have been carried out to consider conductor's suitability in a pulse SMES. In addition, the measured results are compared with AC-loss simulations.

M Lyly; I Hiltunen; J Jrvel; A Korpela; L Lehti; A Stenvall; R Mikkonen

2010-01-01T23:59:59.000Z

453

A nonlinear robust HVDC control for a parallel AC/DC power system  

E-Print Network [OSTI]

A nonlinear robust HVDC control for a parallel AC/DC power system Hongzhi Cai a , Zhihua Qu b. Keywords: Robust control; HVDC; Power system; Stability; Lyapunov method 1. Introduction It has been recognized that, through an HVDC transmission line, fast electronic control can be applied on the DC power

Qu, Zhihua

454

,"Geographic Area",,,"Voltage",,,"Capacity Rating (MVa)","In...  

U.S. Energy Information Administration (EIA) Indexed Site

,0,0,0,0,0,"DLCO","I",100 ,"U","RFC",0,"AC",345,345,1195,"applicationvnd.ms-excel","JK Smith","Spurlock Avon",17.5,"OH","H","S",954,"ACSR",2,2,2,0,"EKPC","C",100...

455

Westar Energy Inc | Open Energy Information  

Open Energy Info (EERE)

Westar Energy Inc Westar Energy Inc Jump to: navigation, search Name Westar Energy Inc Place Topeka, Kansas Utility Id 22500 Utility Location Yes Ownership I NERC Location SPP NERC ERCOT Yes NERC MRO Yes NERC RFC Yes NERC SERC Yes NERC SPP Yes ISO Ercot Yes RTO PJM Yes RTO SPP Yes ISO MISO Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] SGIC[3] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Westar Energy, Inc. Smart Grid Project was awarded $19,041,565 Recovery Act

456

Westar Energy Inc | Open Energy Information  

Open Energy Info (EERE)

Westar Energy Inc Westar Energy Inc (Redirected from Kansas Gas & Electric Co) Jump to: navigation, search Name Westar Energy Inc Place Topeka, Kansas Utility Id 22500 Utility Location Yes Ownership I NERC Location SPP NERC ERCOT Yes NERC MRO Yes NERC RFC Yes NERC SERC Yes NERC SPP Yes ISO Ercot Yes RTO PJM Yes RTO SPP Yes ISO MISO Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] SGIC[3] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it.

457

Conectiv Energy Supply Inc. | Open Energy Information  

Open Energy Info (EERE)

Supply Inc. Supply Inc. (Redirected from Conectiv Energy Services Inc) Jump to: navigation, search Name Conectiv Energy Supply Inc. Place Delaware Utility Id 4318 Utility Location Yes Ownership W NERC RFC Yes RTO PJM Yes ISO NY Yes ISO MISO Yes ISO NE Yes Activity Buying Transmission Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Conectiv_Energy_Supply_Inc.&oldid=412242"

458

Village of Minster, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Minster, Ohio (Utility Company) Minster, Ohio (Utility Company) Jump to: navigation, search Name Village of Minster Place Ohio Utility Id 12660 Utility Location Yes Ownership M NERC Location ECAR NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial General Service Rate 1 Single Phase Commercial Commercial General Service Rate 1 Three Phase Commercial Commercial General Service Rate 2 Single Phase Commercial Commercial General Service Rate 2 Three Phase Commercial Industrial General Service Rate 1 Single Phase Industrial Industrial General Service Rate 1 Three Phase Industrial

459

City of Bedford, Virginia (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Bedford Bedford Place Virginia Utility Id 1456 Utility Location Yes Ownership M NERC Location RFO NERC RFC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Service- Large 120 to 1000 Volts Industrial General Service- Large Over 1000 Volts Industrial Industrial power 4 Industrial Large capacity power 2.4 - 40 KV Industrial Large capacity power Over 40 KV Industrial Outdoor Lighting-Overhead Lighting Service-For each 175 w MV/100 w HPS

460

Old Dominion Electric Coop | Open Energy Information  

Open Energy Info (EERE)

Old Dominion Electric Coop Old Dominion Electric Coop Place Virginia Utility Id 40229 Utility Location Yes Ownership C NERC Location SERC NERC RFC Yes NERC SERC Yes RTO PJM Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Old_Dominion_Electric_Coop&oldid=411269

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

JP Morgan | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search Jump to: navigation, search Name JP Morgan Place Texas Utility Id 56528 Utility Location Yes Ownership R NERC ERCOT Yes NERC FRCC Yes NERC MRO Yes NERC NPCC Yes NERC RFC Yes NERC SERC Yes NERC SPP Yes NERC WECC Yes ISO CA Yes ISO Ercot Yes RTO PJM Yes ISO NY Yes RTO SPP Yes ISO MISO Yes ISO NE Yes ISO Other Yes Activity Retail Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=JP_Morgan&oldid=410888

462

Electrogenerated Chemiluminescence Immunosensor for Bacillus thuringiensis Cry1Ac Based on Fe3O4@Au Nanoparticles  

Science Journals Connector (OSTI)

The electrode was subsequently immersed in 1% BSA solution to seal the non-specific sites on the particle surface and then rinsed with PBST. ... Effect of (a) incubation time and (b) incubation temperature on the ECL intensity: (a) 0.05 mol/L Tris-HCl buffer (pH 8.5) containing 0.6 mmol/L luminol and 1 mmol/L glucose, incubation at 35 1.0 C, 0.2 ng/mL Cry1Ac, 25 ?L of anti-Cry1Ac/Fe3O4@Au particles, and 21 ng/mL GOD-labeled anti-Cry1Ac and (b) 0.05 mol/L Tris-HCl buffer (pH 8.5) containing 0.6 mmol/L luminol and 1 mmol/L glucose, incubation for 30 min, 0.2 ng/mL Cry1Ac, 25 ?L of anti-Cry1Ac/Fe3O4@Au particles, and 21 ng/mL GOD-labeled anti-Cry1Ac. ... Influence of (a) anti-Cry1Ac/Fe3O4@Au particle volume and (b) concentration of GOD-labeled anti-Cry1Ac on the ECL intensity: (a) 0.05 mol/L Tris-HCl buffer (pH 8.5) containing 0.6 mmol/L luminol and 1 mmol/L glucose, incubation at 35 1.0 C for 30 min, 0.2 ng/mL Cry1Ac, and 21 ng/mL GOD-labeled anti-Cry1Ac and (b) 0.05 mol/L Tris-HCl buffer (pH 8.5) containing 0.6 mmol/L luminol and 1 mmol/L glucose, incubation at 35 1.0 C for 30 min, 0.2 ng/mL Cry1Ac, and 25 ?L of anti-Cry1Ac/Fe3O4@Au particles. ...

Jianping Li; Qian Xu; Xiaoping Wei; Zaibin Hao

2013-01-14T23:59:59.000Z

463

Review of the design and performance features of hvdc systems connected to low short circuit ratio ac systems  

SciTech Connect (OSTI)

The design and performance of an HVdc system is significantly impacted by the relative strength of the ac system to which it is connected. In this paper, design and performance features of ten HVdc systems are discussed. All of these systems are connected to ac systems that are relatively weak compared to the rating of the dc system. Six of these systems are back-to-back, two are overhead lines, and two are undersea cable connections. AC and dc system interaction problems and how they are addressed in the design and specification of each of these systems, are described.

Thallam, R.S. (Salt River Project, Phoenix, AZ (United States))

1992-10-01T23:59:59.000Z

464

BWXT/B&W Pantex Contract No. DE-AC04-00AL66620 FY BUDGET  

National Nuclear Security Administration (NNSA)

BWXTB&W Pantex Contract No. DE-AC04-00AL66620 FY BUDGET (LAB TABLE) ESTIMATED COST AWARD FEE AVAILABLE WFO FEE AVAILABLE (Estimated) AVAILABLE FEE FROM OTHER REIMBURSABLE WORK...

465

A High Frequency Isolated Current-fed Bidirectional DC/AC Converter For Grid-Tied Energy Storage System  

E-Print Network [OSTI]

tied energy storage systems (ESS) will be voltage to a high-DC/AC converter to interface ESS based on low voltage cellscharging and discharging of the ESS and the control strategy

King Jet, TSENG

2013-01-01T23:59:59.000Z

466

*s.watt@bangor.ac.uk Achieving near-correct focus cues in a 3-D display using multiple  

E-Print Network [OSTI]

*s.watt@bangor.ac.uk Achieving near-correct focus cues in a 3-D display using multiple image planes Simon J. Watt* a , Kurt Akeley b , Ahna R. Girshick c , Martin S. Banks c a School of Psychology

Banks, Marty

467

The Spectrum and Frequency of Self-Inflicted and Host Gene Mutations Produced by the Transposon Ac in Maize  

Science Journals Connector (OSTI)

...responsible for distribution of materials integral to the findings presented...Various Ac Mutations. The diagrams illustrate DNA replication...pairwise-deletion option for handling gaps. Accession Numbers Sequence...Supplemental Data The following materials are available in the online...

Jun T. Huang; Hugo K. Dooner

2012-10-30T23:59:59.000Z

468

An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.  

SciTech Connect (OSTI)

References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

Litzenberger, Wayne; Lava, Val

1994-08-01T23:59:59.000Z

469

AC 2011-1335: STUDENTS AND SUSTAINABILITY: ASSESSING STU-DENTS' UNDERSTANDING OF SUSTAINABILITY FROM SERVICE LEARN-  

E-Print Network [OSTI]

AC 2011-1335: STUDENTS AND SUSTAINABILITY: ASSESSING STU- DENTS' UNDERSTANDING OF SUSTAINABILITY, Environmental, and Architectural Engineering at the University of Colorado at Boulder (CU). She served research interests pertaining to engineering education include learning through service, sustainability

470

Hardware model of a shipboard zonal electrical distribution system (ZEDS) : alternating current/direct current (AC/DC)  

E-Print Network [OSTI]

A hardware model of a shipboard electrical distribution system based on aspects of the DDG 51 Flight IIA, Arleigh Burke class, 60Hz Alternating Current (AC) and the future direct current (DC), zonal electrical distribution ...

Tidd, Chad N. (Chad Norman)

2010-01-01T23:59:59.000Z

471

A new high performance AC to DC rectifier with input power factor correction and harmonic reduction capacity  

E-Print Network [OSTI]

Many conventional switching power supplies in data processing equipment and low power motor drive systems operate by rectifying the input ac line voltage and filtering it with large electrolytic capacitors. Because this process involves both...

Martinez, Roberto

2012-06-07T23:59:59.000Z

472

Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830  

E-Print Network [OSTI]

PNNL-21950 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Recommended Job Code V6237 U.S. Nuclear Regulatory Commission Office of Nuclear Regulatory Research Washington, D

473

Mainstream Engineering Develops a Low-Cost Energy-Saving Device for A/C  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Mainstream Engineering Develops a Low-Cost Energy-Saving Device Mainstream Engineering Develops a Low-Cost Energy-Saving Device for A/C Systems Small Business Innovation Research (SBIR) and Small Business Technology Transfer (STTR) SBIR/STTR Home About Funding Opportunity Announcements (FOAs) Applicant and Awardee Resources Commercialization Assistance Other Resources Awards SBIR/STTR Highlights Reporting Fraud Contact Information Small Business Innovation Research and Small Business Technology Transfer U.S. Department of Energy SC-29/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-5707 F: (301) 903-5488 E: sbir-sttr@science.doe.gov More Information » January 2013 Mainstream Engineering Develops a Low-Cost Energy-Saving Device for A/C Systems Mainstream is achieving its goal to commercialize practical and

474

Surplus Facilities Management Program (SFMP) Contract No. DE-AC05-810R20722  

Office of Legacy Management (LM)

'^ l '"17 '^ l '"17 ^' ~/t~ >7~ 6~'1 ~DOE/OR/20722-18 Surplus Facilities Management Program (SFMP) Contract No. DE-AC05-810R20722 NIAGARA FALLS STORAGE SITE ENVIRONMENTAL MONITORING REPORT Calendar Year 1983 July 1984 Bechtel National, Inc. Advanced Technology Division DOE/OR/20722-18 NIAGARA FALLS STORAGE SITE ENVIRONMENTAL MONITORING REPORT CALENDAR YEAR 1983 July 1984 Prepared for U.S. DEPARTMENT OF ENERGY OAK RIDGE OPERATIONS OFFICE Under Contract No. DE-AC05-810R20722 By Bechtel National, Inc. Advanced Technology Division Oak Ridge, Tennessee 37830 Bechtel Job No. 14501 *4:F~~~~ ^ABSTRACT During 1983, an environmental monitoring program was continued at the Niagara Falls Storage Site, a United States Department of Energy (DOE) surplus facility located in Niagara County, New York presently

475

Data:82669655-9455-4500-a883-ac345410ec12 | Open Energy Information  

Open Energy Info (EERE)

9455-4500-a883-ac345410ec12 9455-4500-a883-ac345410ec12 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Delmarva Power Effective date: 2013/06/01 End date if known: Rate name: OL "HPS" 50 Watt (Enclosed) (Existing) 21 kW Sector: Lighting Description: Source or reference: http://www.delmarva.com/_res/documents/DEMasterTariff.pdf Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months): Service Voltage Minimum (V): Maximum (V): Character of Service Voltage Category: Phase Wiring: << Previous

476

High-field ac susceptometer using Helmholtz coils as a magnetizer  

Science Journals Connector (OSTI)

An ac susceptometer is designed for measuring ac susceptibility of disc, film or tape samples of high-temperature superconductors at 77 K in an applied field as high and uniform as possible. It is equipped with a pair of magnetizing Helmholtz coils and a pair of coaxial concentric measuring?compensating coils. For this, the field uniformity and impedance of the magnetizing Helmholtz coils with square coil cross-section and the flux linkage in the measuring?compensating coils produced by the sample moment are systematically and accurately computed based on the analytical formulae for the mutual inductance between two loops and the self-inductance of a thin solenoid. Problems related to the susceptometer calibration and the susceptibility measurements are discussed.

D-X Chen

2004-01-01T23:59:59.000Z

477

Resistivity measurements of iodine single crystals by an A.C. technique  

E-Print Network [OSTI]

The temperature dep ndence of th. ! capac! tance of tvlo iodine sin;, le crystals. Iiessur. . cents on samp! e 8 acre rinds in the c- crystallo''rcphic diection and those on samo) e C 0 . , 'DPlatl 5 ( !Gout PP5' ) in the a-c p]ane. 20 :t. CI 0 Lu LIJ LJ I... The temperature dep ndence of th. ! capac! tance of tvlo iodine sin;, le crystals. Iiessur. . cents on samp! e 8 acre rinds in the c- crystallo''rcphic diection and those on samo) e C 0 . , 'DPlatl 5 ( !Gout PP5' ) in the a-c p]ane. 20 :t. CI 0 Lu LIJ LJ I...

Intararithi, Thanom

2012-06-07T23:59:59.000Z

478

Why an ac Magnetic Field Shifts the Irreversibility Line in Type-II Superconductors  

Science Journals Connector (OSTI)

We show that for a thin superconducting strip placed in a transverse dc magnetic fieldthe typical geometry of experiments with high- Tc superconductorsthe application of a weak ac magnetic field perpendicular to the dc field generates a dc voltage in the strip. This voltage leads to the decay of the critical currents circulating in the strip, and eventually the equilibrium state of the superconductor is established. This relaxation is not due to thermally activated flux creep but to the walking motion of vortices in the two-dimensional critical state of the strip with in-plane ac field. Our theory explains the shaking effect that was used for detecting phase transitions of the vortex lattice in superconductors.

Ernst Helmut Brandt and Grigorii P. Mikitik

2002-06-20T23:59:59.000Z

479

Critical behavior of strained epitaxial Gd films: In situ ac-susceptibility measurements in UHV  

Science Journals Connector (OSTI)

300- Gd films grown on W(110) under UHV conditions have been investigated Iin situR by ac-susceptibility measurements above and below Tc. A sharp peak of ?ac=230 is observed. To our knowledge, this is the largest and sharpest (2?=1 K) cusp measured for a rare-earth ferromagnet. No domain-wall signal is superimposed upon the divergence of the paramagnetic susceptibility. At Tc+ we find ?=?0t-? with ?=1.235(25). This is clear evidence for a three-dimensional Ising-like behavior above Tc. The sharpness and peak position of ?(T) change, depending on the annealing temperature. Simultaneously, a change in the LEED pattern is observed.

U. Stetter, M. Farle, K. Baberschke, and W. G. Clark

1992-01-01T23:59:59.000Z

480

Construction of AC Motor Controllers for NOvA Experiment Upgrades  

SciTech Connect (OSTI)

I have been constructing Alternating Current (AC) motor controllers for manipulation of particle beam detectors. The capability and reliability of these motor controllers are essential to the Laboratory's mission of accurate analysis of the particle beam's position. The device is moved in and out of the beam's path by the motor controller followed by the Neutrinos at the Main Injector Off-Axis {nu}{sub e} Appearance (NOvA) Experiment further down the beam pipe. In total, I built and tested ten ac motor controllers for new beam operations in the NOvA experiment. These units will prove to be durable and provide extremely accurate beam placement for NOvA Experiment far into the future.

Cooley, Patrick; /Fermilab; ,

2011-08-04T23:59:59.000Z

Note: This page contains sample records for the topic "rfc pjm ac" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Dirty, Skewed, and Backwards: The Smectic A-C Phase Transition in Aerogel  

Science Journals Connector (OSTI)

We study the smectic A-C transition in anisotropic and uniaxial disordered environments, e.g., uniaxially stretched aerogel. We find very strange behavior of translational correlations: the low-temperature, lower-symmetry smectic C phase is less translationally ordered than the high-temperature, higher-symmetry smectic A phase, with short ranged and algebraic translational correlations, respectively. Specifically, the A and C phases belong to the quasi-long-ranged translationally ordered XY Bragg glass and short ranged translationally ordered m=1 Bragg glass phase, respectively. The A-C phase transition itself belongs to a new universality class, whose fixed points and exponents we find in a d=5-? expansion.

Leiming Chen and John Toner

2005-04-08T23:59:59.000Z

482

Data:B2147800-fbad-4023-ac70-a3191135d085 | Open Energy Information  

Open Energy Info (EERE)

7800-fbad-4023-ac70-a3191135d085 7800-fbad-4023-ac70-a3191135d085 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Stafford, Kansas (Utility Company) Effective date: End date if known: Rate name: E9 - 9 Horsepower Sector: Commercial Description: Source or reference: https://cas.sharepoint.illinoisstate.edu/grants/Sunshot/Lists/DATA%20ENTRY%20Rates%20Collected/Attachments/627/rate%20information%20for%20Stafford.pdf Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months): Service Voltage Minimum (V):

483

acs_cm_cm-2009-03769q 1..3  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

pubs.acs.org/cm pubs.acs.org/cm Published on Web 02/16/2010 r 2010 American Chemical Society Chem. Mater. 2010, 22, 1943-1945 1943 DOI:10.1021/cm903769q Universal and Solution-Processable Precursor to Bismuth Chalcogenide Thermoelectrics Robert Y. Wang, † Joseph P. Feser, ‡ Xun Gu, § Kin Man Yu, † Rachel A. Segalman, †,§ Arun Majumdar, †,‡ Delia J. Milliron,* ,† and Jeffrey J. Urban* ,† † Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, ‡ Department of Mechanical Engineering, and § Department of Chemical Engineering, University of California, Berkeley, California 94720 Received December 15, 2009 Revised Manuscript Received February 7, 2010 Thermoelectric materials convert thermal power into electrical power and vice versa. In practice, thermoelectric coolers and power generators are made by alternately

484

Methodology for integration of HVDC links in large ac systems. Phase I. Reference manual. Final report  

SciTech Connect (OSTI)

HVDC transmission has been found to be an attractive alternative to ac transmission in many situations. Evaluations of HVDC alternatives include technical, economic, environmental and sometimes regulatory considerations which are different than those for ac transmission. This research project resulted in the preparation of a HVDC reference manual which describes a comprehensive methodology for evaluating HVDC alternatives in utility transmission planning. It provides basic background information about existing HVDC systems. It describes the types of studies required and potential problems which must be dealt with. It also discusses how the studies are usually run and what system modeling is required. It emphasizes the importance of proper control of the dc system and provides examples of control systems which have been used.

Meredith, R.J.

1983-03-01T23:59:59.000Z

485

Protecting a HVDC link against accidental isolation from its receiving AC system  

SciTech Connect (OSTI)

When an HVdc scheme is isolated from its receiving ac system, the inverter may continue to operate, generating its own ac bus voltages; this is defined here as islanding. If islanding is allowed to continue unrestricted, then main circuit components may in some conditions be damaged and it is therefore necessary to provide a suitable protection system. This paper outlines the protection scheme developed for the McNeill Back-to-Back HVdc link in Alberta, Canada, to prevent damage due to islanding while still permitting the link to automatically restart on reclosure of the isolating breaker. Oscillograms showing the protection in operation on both the GEC ALSTHOM HVdc simulator and during tests carried out as part of the commissioning of the McNeill HV dc link are included.

Whitehouse, R.S. (GEC Alsthom Transmission and Distribution Projects Ltd., Stafford (United Kingdom))

1993-07-01T23:59:59.000Z

486

Dynamic Resistance of YBCO-Coated Conductors in Applied AC Fields with DC Transport Currents and DC Background Fields  

SciTech Connect (OSTI)

In order to predict heat loads in future saturable core fault-current-limiting devices due to ac fringing fields, dynamic resistance in YBCO-coated conductors was measured at 77 K in peak ac fields up to 25 mT at 60 Hz and in dc fields up to 1 T. With the sample orientation set such that the conductor face was either parallel or perpendicular to the ac and dc applied fields, the dynamic resistance was measured at different fractions of the critical current to determine the relationship between the dc transport current and the applied fields. With respect to field orientation, the dynamic resistance for ac fields that were perpendicular to the conductor face was significantly higher than when the ac fields were parallel to the conductor face. It was also observed that the dynamic resistance: (1) increased with increasing fraction of the dc transport current to the critical current, (2) was proportional to the inverse of the critical current, and (3) demonstrated a linear dependence with the applied ac field once a threshold field was exceeded. This functional behavior was consistent with a critical state model for the dynamic resistance, but discrepancies in absolute value of the dynamic resistance suggested that further theoretical development is needed.

Duckworth, Robert C [ORNL] [ORNL; Zhang, Yifei [ORNL] [ORNL; Ha, Tam T [ORNL] [ORNL; Gouge, Michael J [ORNL] [ORNL

2011-01-01T23:59:59.000Z

487

AVTA: GE Energy WattStation AC Level 2 Charging System Testing Results  

Broader source: Energy.gov [DOE]

The Vehicle Technologies Office's Advanced Vehicle Testing Activity carries out testing on a wide range of advanced vehicles and technologies on dynamometers, closed test tracks, and on-the-road. These results provide benchmark data that researchers can use to develop technology models and guide future research and development. The following report describes results from testing done on the GE Energy Wattstation AC Level 2 charging system for plug-in electric vehicles.

488

AVTA: ChargePoint AC Level 2 Charging System Testing Results  

Broader source: Energy.gov [DOE]

The Vehicle Technologies Office's Advanced Vehicle Testing Activity carries out testing on a wide range of advanced vehicles and technologies on dynamometers, closed test tracks, and on-the-road. These results provide benchmark data that researchers can use to develop technology models and guide future research and development. The following report describes results from testing done on the ChargePoint AC Level 2 charging system for plug-in electric vehicles.

489

Data:Ac1be58a-fdc2-4dc5-be16-8ac5f844e141 | Open Energy Information  

Open Energy Info (EERE)

8a-fdc2-4dc5-be16-8ac5f844e141 8a-fdc2-4dc5-be16-8ac5f844e141 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Otero County Electric Coop Inc Effective date: 2010/03/04 End date if known: Rate name: General Service - Optional Rate Sector: Commercial Description: Demand Charge per KW: (above 10kw) Otero County Electric Cooperative, Inc. (OCEC), with its April 10 billing, will initiate a new program involving Energy Efficiency and rebates on certain items. The new "Energy Efficiency Fund" program will begin with the March 1 kWh usage. The program will be financed by a one percent adder to Members' bills and also by retaining the inspection and supervision fees that were previously paid to the New Mexico Public Regulation Commission (PRC). The OCEC Board of Trustees (Board) approved the basics of the fund at the January Board Meeting and will determine those programs that continue to provide the needed services to our Members.

490

Data:Ac9ace5f-ac04-4662-ada3-21a5711f4d40 | Open Energy Information  

Open Energy Info (EERE)

ace5f-ac04-4662-ada3-21a5711f4d40 ace5f-ac04-4662-ada3-21a5711f4d40 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Johnson City, Tennessee (Utility Company) Effective date: 2003/10/01 End date if known: Rate name: SECURITY LIGHTS 250 WATT SODIUM VAPOR Sector: Lighting Description: PRESENT RATES FOR SECURITY LIGHTS - EFFECTIVE 10/1/03 - PLUS POLE CHARGE WHERE APPLICABLE Source or reference: http://www.jcpb.com/yourBusiness/meters/rates.asp#rateSheet Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months):

491

Turning on the Fan and Turning off the A/C | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Turning on the Fan and Turning off the A/C Turning on the Fan and Turning off the A/C Turning on the Fan and Turning off the A/C September 20, 2010 - 3:00pm Addthis As part of some recent money- and energy-savings improvements I've been making to my home, a couple of weeks ago I installed a ceiling fan in my main living room. Chris Stewart Senior Communicator at DOE's National Renewable Energy Laboratory As part of some recent money- and energy-savings improvements I've been making to my home, a couple of weeks ago I installed a ceiling fan in my main living room. Part of my research led me to understand how ceiling fans are considered the most effective fans compared among table fans, floor fans, and fans mounted to poles or walls because they effectively circulate the air in a room to create a draft throughout the room.

492

Turning on the Fan and Turning off the A/C | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Turning on the Fan and Turning off the A/C Turning on the Fan and Turning off the A/C Turning on the Fan and Turning off the A/C September 20, 2010 - 3:00pm Addthis As part of some recent money- and energy-savings improvements I've been making to my home, a couple of weeks ago I installed a ceiling fan in my main living room. Chris Stewart Senior Communicator at DOE's National Renewable Energy Laboratory As part of some recent money- and energy-savings improvements I've been making to my home, a couple of weeks ago I installed a ceiling fan in my main living room. Part of my research led me to understand how ceiling fans are considered the most effective fans compared among table fans, floor fans, and fans mounted to poles or walls because they effectively circulate the air in a room to create a draft throughout the room.

493

Noise-induced dephasing of an ac-driven Josephson junction  

E-Print Network [OSTI]

We consider phase-locked dynamics of a Josephson junction driven by finite-spectral-linewidth ac current. By means of a transformation, the effect of frequency fluctuations is reduced to an effective additive noise, the corresponding (large) dephasing time being determined, in the logarithmic approximation, by the Kramers' expression for the lifetime. For sufficiently small values of the drive's amplitude, direct numerical simulations show agreement of the dependence of the dephasing activation energy on the ac-drive's spectral linewidth and amplitude with analytical predictions. Solving the corresponding Fokker-Planck equation analytically, we find a universal dependence of a critical value of the effective phase-diffusion parameter on the drive's amplitude at a point of a sharp transition from the phase-locked state to an unlocked one. For large values of the drive amplitude, saturation and subsequent decrease of the activation energy are revealed by simulations, which cannot be accounted for by the perturbative analysis. The same new effect is found for a previously studied case of ac-driven Josephson junctions with intrinsic thermal noise. The work was performed in the framework of a cooperation agreement between Consiglio Nazionale di Ricerca (Italy) and the Israeli Ministry of Science and Technology.

Giovanni Filatrella; Boris A. Malomed; Sergio Pagano

2002-03-28T23:59:59.000Z

494

Rotor dynamic analysis of GCEP (Gas Centrifuge Enrichment Plant) Tails Withdrawal Test Facility AC-12 compressor  

SciTech Connect (OSTI)

The reliable operation of the centrifugal compressors utilized in the gaseous diffusion process is of great importance due to the critical function of these machines in product and tails withdrawal, cascade purge and evacuation processes, the purge cascade and product booster applications. The same compressors will be used in equally important applications within the Gas Centrifuge Enrichment Plant (GCEP). In response to concern over the excessive vibration exhibited by the AC-12 compressor in the No. 3 position of the GCEP Tails Withdrawal Test Facility, a rotor-bearing dynamic analysis was performed on the compressor. This analysis included the acquisition and reduction of compressor vibration data, characterization and modeling of the rotorbearing system, a computer dynamic study, and recommendations for machine modification. The compressor dynamic analysis was performed for rotor speeds of 9000 rpm and 7200 to 7800 rpm, which includes all possible opreating speeds of the compressor in the GCEP Test Facility. While the analysis was performed on this particular AC-12 compressor, the results should be pertinent to other AC-12 applications as well. Similar diagnostic and analytical techniques can be used to evaluate operation of other types of centrifugal compressors.

Spencer, J.W.

1982-01-22T23:59:59.000Z

495

Interpretation of the harmonic response of superconducting films to inhomogeneous ac magnetic fields  

Science Journals Connector (OSTI)

We present a quantitative analysis of the response of a thin superconducting film to an applied nonuniform ac magnetic field. The analysis is directly applicable to the single-coil inductive measurement technique where a small coil driven by an ac current produces a nonuniform field, with JC determined by the appearance of a third-harmonic component of the voltage generated across the coil. We derive a simple model to explain the response of the film to the applied magnetic field in the absence of weak links. This model is used to predict the third-harmonic voltage generated across the coil. The derivation of the model explains why superconducting films having thicknesses even less than the penetration depth screen out the nonuniform ac magnetic fields generated by the coil. A simplified version of the model yields analytic expressions that describe the magnitude and phase of the third-harmonic component at high drive currents while the full model yields excellent agreement with experimental measurements for our highest quality epitaxial films. In other films, the presence of weak links leads to a characteristic signature in the harmonic response at low drive currents. We have also found that ion irradiation can reduce the critical current densities by significant amounts without introducing weak links into the film.

G. D. Poulin; J. S. Preston; T. Strach

1993-07-01T23:59:59.000Z

496

Improving the dynamic performance of a complex AC/DC system by HVDC control modifications  

SciTech Connect (OSTI)

The power system of Hydro-Quebec has a peak load of approximately 27 GW. The great distance between the production sites and the load centers introduces stability limitations, which is the reason why the Quebec grid cannot be economically synchronized (through ac transmission with limited capacity) with the U.S. northeastern network. Power exports are therefore dependent on the use of HVDC links of which Hydro-Quebec now possesses five, for a capacity of over 2600 MW. Such a capacity will again soon increase. At the moment, the Chateauguay scheme has the largest HVDC capacity. It transfers 1000 MW by means of two Back-to-Back converter blocks. Various automatic control systems are installed on the Chateauguay scheme owing to the fact that a single circuit of a 765 kV ac line transmits the output of both the HVDC converter stations as well as the output from Beauharnois hydro generating station. Such controls have performed satisfactorily since 1984. However, a remarkable improvement of the overall ac/dc system dynamic performance can be gained by making certain modifications in some of these HVDC system controls. This paper presents the salient features of such control modifications, currently under consideration, using the results of an investigation by digital and analogue simulations that demonstrate the achieved improvements.

Hammad, A.E. (ABB Power Systems, Baden (CH)); Gagnon, J. (Hydro Quebec, Montreal (CA)); McCallum, D. (IREQ, Montreal (CA))

1990-10-01T23:59:59.000Z

497

Pennsylvania Electric Co | Open Energy Information  

Open Energy Info (EERE)

Place Ohio Place Ohio Utility Id 14711 Utility Location Yes Ownership I NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png RS Residential RT (Time-Of-Day) Residential Average Rates No Rates Available The following table contains monthly sales and revenue data for Pennsylvania Electric Co (Pennsylvania). Month RES REV (THOUSAND $) RES SALES (MWH) RES CONS COM REV (THOUSAND $) COM SALES (MWH) COM CONS IND_REV (THOUSAND $) IND SALES (MWH) IND CONS OTH REV (THOUSAND $) OTH SALES (MWH) OTH CONS TOT REV (THOUSAND $) TOT SALES (MWH) TOT CONS

498

The Potomac Edison Co | Open Energy Information  

Open Energy Info (EERE)

Pennsylvania Pennsylvania Utility Id 15263 Utility Location Yes Ownership I NERC Location RFC NERC NPCC Yes NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png A-8 (Residential Service) Residential R Residential S-4 (Seasonal Residential) Residential Average Rates No Rates Available The following table contains monthly sales and revenue data for The Potomac Edison Co (Maryland). Month RES REV (THOUSAND $) RES SALES (MWH) RES CONS COM REV (THOUSAND $) COM SALES (MWH) COM CONS IND_REV (THOUSAND $) IND SALES (MWH) IND CONS OTH REV (THOUSAND $) OTH SALES (MWH) OTH CONS TOT REV (THOUSAND $) TOT SALES (MWH) TOT CONS

499

Data:0ac74409-f2ac-4fb5-89ca-2b93352f3c66 | Open Energy Information  

Open Energy Info (EERE)

4409-f2ac-4fb5-89ca-2b93352f3c66 4409-f2ac-4fb5-89ca-2b93352f3c66 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Indianapolis Power & Light Co Effective date: 2011/03/15 End date if known: Rate name: MU-1 - a1b - 1000 watt MV Sector: Lighting Description: Lamps in enclosed fixtures, mounted on metal or fiberglass columns and supplied from underground circuits. APPLICABILITY: For Street and Traffic Lighting of public streets, parkways, improved alleys, boulevards, drives, bridges, parking areas, or other public places by Cities or Towns or by individuals, groups of individuals, associations and other than incorporated municipalities; and lighting of public parks, drives, bridges, parking areas or other public places by only Cities or Towns where there is a prospect that the capital expenditure is warranted. The capital expenditure will be warranted if the amount of revenue received in sixty (60) months exceeds the estimated cost of installation for the lights as calculated by the Company. If the 60-month revenue does not exceed the cost of installation, the Customer must pay two and one-half (2½) times the difference of the cost of installation and the 60-month revenue prior to installation of the lighting. The terms, prices and provisions of this rate schedule shall be applicable to a consolidated city of the first class only to the extent not inconsistent with the specifications, terms, prices and provisions in contracts which may be entered into by such city pursuant to I.C. § 36-9-9-1, et. seq.

500

Comparison of the Accuracy and Speed of Transient Mobile A/C System Simulation Models: Preprint  

SciTech Connect (OSTI)

The operation of air conditioning (A/C) systems is a significant contributor to the total amount of fuel used by light- and heavy-duty vehicles. Therefore, continued improvement of the efficiency of these mobile A/C systems is important. Numerical simulation has been used to reduce the system development time and to improve the electronic controls, but numerical models that include highly detailed physics run slower than desired for carrying out vehicle-focused drive cycle-based system optimization. Therefore, faster models are needed even if some accuracy is sacrificed. In this study, a validated model with highly detailed physics, the 'Fully-Detailed' model, and two models with different levels of simplification, the 'Quasi-Transient' and the 'Mapped- Component' models, are compared. The Quasi-Transient model applies some simplifications compared to the Fully-Detailed model to allow faster model execution speeds. The Mapped-Component model is similar to the Quasi-Transient model except instead of detailed flow and heat transfer calculations in the heat exchangers, it uses lookup tables created with the Quasi-Transient model. All three models are set up to represent the same physical A/C system and the same electronic controls. Speed and results of the three model versions are compared for steady state and transient operation. Steady state simulated data are also compared to measured data. The results show that the Quasi-Transient and Mapped-Component models ran much faster than the Fully-Detailed model, on the order of 10- and 100-fold, respectively. They also adequately approach the results of the Fully-Detailed model for steady-state operation, and for drive cycle-based efficiency predictions

Kiss, T.; Lustbader, J.

2014-03-01T23:59:59.000Z