Sample records for revenue meter replacement

  1. Algorithms for revenue metering and their evaluation 

    E-Print Network [OSTI]

    Martinez-Lagunes, Rodrigo

    2000-01-01T23:59:59.000Z

    Power components are measured for revenue metering and other purposes such as power control and power factor compensation. The definitions of the power components (active, reactive and apparent power, as well as, power factor) under sinusoidal...

  2. Algorithms for revenue metering and their evaluation

    E-Print Network [OSTI]

    Martinez-Lagunes, Rodrigo

    2000-01-01T23:59:59.000Z

    ALGORITHMS FOR REVENUE METERING AND THEIR EVALUATION A Thesis by RODRIGO MARTINEZ-LAGUNES Submitted to the Office of Graduate Studies of Texas AdcM University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE May... 2000 Major Subject: Electrical Engineering ALGORITHMS FOR REVENUE METERING AND THEIR EVALUATION A Thesis By RODRIGO MARTINEZ-LAGUNES Submitted to Texas A&M University in partial fulfillment of the requirements for the degree of MASTER...

  3. Why Insertion Turbine Meters are Replacing Orifice Plates for Steam Flow Measurement

    E-Print Network [OSTI]

    Rusnak, J. J.

    1983-01-01T23:59:59.000Z

    WHY INSERTION TURBINE MBTBRS A E REPLACING ORIFICE PLATES FOR STEAM FLOW MEASURE ENT J. J. Rusnak Engineering Measurements Company Longmont, Colorado ABSTRACT Flow measurement is a complex and application related discipline. It borders... to be instrumented quickly, economically and without dis rupting production; and further, these meters had to be accurate in order to be useful in making energy saving decisions. Thus, the entry of the insertion turbine meter for steam in 1975. Since then it has...

  4. Economic and Conservation Evaluation of Capital Renovation Projects: Harlingen Irrigation District Cameron County No. 1 Canal Meters and Telemetry Equipment, Impervious-Lining of Delivery Canals, Pipelines Replacing Delivery Canals, and On-Farm Delivery-Site Meters

    E-Print Network [OSTI]

    Rister, M. Edward; Lacewell, Ronald D.; Sturdivant, Allen W.; Robinson, John R.C.; Popp, Michael C.; Ellis, John R.

    TR-202 October 2002 Economic and Conservation Evaluation of Capital Renovation Projects: Harlingen Irrigation District Cameron County No. 1 – Canal Meters and Telemetry Equipment, Impervious-Lining of Delivery Canals, Pipelines Replacing Delivery... Canals, and On-Farm Delivery-Site Meters M. Edward Rister Ronald D. Lacewell Allen W. Sturdivant John R. C. Robinson Michael C. Popp John R. Ellis Texas Water Resources Institute Texas A&M University TR-202 October 2002 Economic and Conservation...

  5. Net Metering

    Broader source: Energy.gov [DOE]

    In April 2008, Kentucky enacted legislation that expanded its net metering law by requiring utilities to offer net metering to customers that generate electricity with photovoltaic (PV), wind,...

  6. Net Metering

    Broader source: Energy.gov [DOE]

    In Massachusetts, the state's investor-owned utilities must offer net metering. Municipal utilities are not obligated to offer net metering, but they may do so voluntarily. (There are no electric...

  7. Net Metering

    Broader source: Energy.gov [DOE]

    The Indiana Utility Regulatory Commission (IURC) adopted rules for net metering in September 2004, requiring the state's investor-owned utilities (IOUs) to offer net metering to all electric...

  8. Net Metering

    Broader source: Energy.gov [DOE]

    New Jersey's net-metering rules apply to all residential, commercial and industrial customers of the state's investor-owned utilities and energy suppliers (and certain competitive municipal...

  9. Net Metering

    Broader source: Energy.gov [DOE]

    Wyoming enacted legislation in February 2001 that established statewide net metering. The law applies to investor-owned utilities, electric cooperatives and irrigation districts. Eligible...

  10. Net Metering

    Broader source: Energy.gov [DOE]

    Net metering has been available in Oklahoma since 1988 under Oklahoma Corporation Commission (OCC) Order 326195. The OCC's rules require investor-owned utilities and electric cooperatives under...

  11. Net Metering

    Broader source: Energy.gov [DOE]

    Missouri enacted legislation in June 2007 (S.B. 54)* requiring all electric utilities -- investor-owned utilities, municipal utilities and electric cooperatives -- to offer net metering to...

  12. Metering Approaches

    Broader source: Energy.gov [DOE]

    Metering approaches vary depending on facility design and intended purpose (e.g., administrative offices, laboratory, warehouse, etc.). No one approach fits all applications. In fact, different...

  13. OPEC Revenues Fact Sheet

    Reports and Publications (EIA)

    2013-01-01T23:59:59.000Z

    This report includes estimates of OPEC net oil export revenues, based on historical estimates and forecasts from the latest Energy Information Administration (EIA) Short-Term Energy Outlook.

  14. Electric $ales and revenue 1995

    SciTech Connect (OSTI)

    NONE

    1996-12-01T23:59:59.000Z

    This publication provides information on electricity sales, associated revenue, average revenue per kilowatthour sold, and number of consumers in the United States.

  15. Net Metering

    Broader source: Energy.gov [DOE]

    Illinois enacted legislation in August 2007 (S.B. 680) requiring investor-owned utilities in Illinois to begin offering net metering by April 1, 2008. In May 2008, the Illinois Commerce Commissio...

  16. Net Metering

    Broader source: Energy.gov [DOE]

    NOTE: In December 15, 2014 the New York Public Service Commission (PSC) issued an order directing the investor owned utilities in the State to file net metering tariff revisions doubling the agg...

  17. Net Metering

    Broader source: Energy.gov [DOE]

    Nevada's original net-metering law for renewable-energy systems was enacted in 1997 and amended in 2001, 2003, 2005, 2007, 2011, 2013, and 2015. Systems up to one megawatt (MW) in capacity that...

  18. Net Metering

    Broader source: Energy.gov [DOE]

    Note: The program web site listed above links to the Maryland Public Service Commission's Net Metering Working Group page, which contains a variety of information resources related to the ongoing...

  19. Net Metering

    Broader source: Energy.gov [DOE]

    [http://nebraskalegislature.gov/FloorDocs/101/PDF/Final/LB436.pdf LB 436], signed in May 2009, established statewide net metering rules for all electric utilities in Nebraska. The rules apply to...

  20. Net Metering

    Broader source: Energy.gov [DOE]

    The North Carolina Utilities Commission (NCUC) requires the state’s three investor-owned utilities -- Duke Energy, Progress Energy and Dominion North Carolina Power -- to make net metering...

  1. Net Metering

    Broader source: Energy.gov [DOE]

    Net metering is available to all "qualifying facilities" (QFs), as defined by the federal Public Utility Regulatory Policies Act of 1978 (PURPA)*, which pertains to systems up to 80 megawatts (MW)...

  2. Net Metering

    Broader source: Energy.gov [DOE]

    Montana's net-metering law, enacted in July 1999, applies to all customers of investor-owned utilities. Systems up to 50 kilowatts (kW) in capacity that generate electricity using solar, wind or...

  3. Net Metering

    Broader source: Energy.gov [DOE]

    The Public Service Commission of Wisconsin (PSC) issued an order on January 26, 1982 requiring all regulated utilities to file tariffs allowing net metering to customers that generate electricity...

  4. Net Metering

    Broader source: Energy.gov [DOE]

    Rhode Island allows net metering for systems up to five megawatts (MW) in capacity that are designed to generate up to 100% of the electricity that a home or other facility uses. Systems that...

  5. Net Metering

    Broader source: Energy.gov [DOE]

    '''''Note: In March 2011, Virginia enacted HB 1983, which increased the residential net-metering limit to 20 kW. However, residential facilities with a capacity of greater than 10 kW must pay a...

  6. Net Metering

    Broader source: Energy.gov [DOE]

    Net metering in West Virginia is available to all retail electricity customers. System capacity limits vary depending on the customer type and electric utility type, according to the following...

  7. Net Metering

    Broader source: Energy.gov [DOE]

    North Dakota's net-metering policy, adopted in 1991 by the state Public Service Commission (PSC), applies to renewable-energy systems and combined heat and power (CHP) systems up to 100 kilowatts ...

  8. Net Metering

    Broader source: Energy.gov [DOE]

    Oregon has established separate net-metering programs for the state's primary investor-owned utilities (PGE and PacifiCorp), and for its municipal utilities and electric cooperatives.

  9. Net Metering

    Broader source: Energy.gov [DOE]

    '''''The MPSC is reviewing state interconnection and net metering policies in [http://efile.mpsc.state.mi.us/efile/viewcase.php?casenum=15919&submit.x=... Case U-15919].'''''...

  10. Net Metering

    Broader source: Energy.gov [DOE]

    '''''NOTE: Legislation enacted in 2011 and 2012 (S.B. 1652, H.B. 3036, and S.B. 3811) has changed several aspects of net metering in Illinois. For customers in competitive classes as of July 1,...

  11. Net Metering

    Broader source: Energy.gov [DOE]

    Utah law requires their only investor-owned utility, Rocky Mountain Power (RMP), and most electric cooperatives* to offer net metering to customers who generate electricity using solar energy, wind...

  12. Net Metering

    Broader source: Energy.gov [DOE]

    Washington's net-metering law applies to systems up to 100 kilowatts (kW) in capacity that generate electricity using solar, wind, hydro, biogas from animal waste, or combined heat and power...

  13. Net Metering

    Broader source: Energy.gov [DOE]

    '''''Note: H.F. 729, enacted in May 2013, includes many changes to Minnesota's net metering law. These changes are described above, but most will not take effect until rules are implemented at the...

  14. The revenue imperative

    E-Print Network [OSTI]

    Flaherty, Jane

    2000-01-01T23:59:59.000Z

    the war. Further, by reviewing the tariff history of the antebellum era, I find that the revenue imperative, more than a desire to impose a "protectionist" or "free trade" doctrine, motivated changes in antebellum tariff legislation....

  15. The Costs and Revenues of

    E-Print Network [OSTI]

    The Costs and Revenues of Transformation to Continuous Cover Forestry Owen Davies & Gary Kerr March 2011 #12;2 | Costs and Revenues of CCF | Owen Davies & Gary Kerr | March 2011 Costs and Revenues of CCF The costs and revenues of transformation to continuous cover forestry: Modelling silvicultural options

  16. Electrical energy metering application at a large research facility

    SciTech Connect (OSTI)

    Falke, S.S.

    1991-05-08T23:59:59.000Z

    A brief history of electric energy metering at Lawrence Livermore National Laboratory is presented. Use of electromechanical watthour demand, solid state single function transducers, analog multifunction, and digital multifunction per-phase metering are discussed. Applications for interdepartment revenue transfer based on energy and power flow, load profiling, system planning, and use as a troubleshooting tool are described. 6 refs.

  17. Saturation meter

    DOE Patents [OSTI]

    Gregurech, S.

    1984-08-01T23:59:59.000Z

    A saturation meter for use in a pressurized water reactor plant comprising a differential pressure transducer having a first and second pressure sensing means and an alarm. The alarm is connected to the transducer and is preset to activate at a level of saturation prior to the formation of a steam void in the reactor vessel.

  18. Technologie Smart metering Technologie Smart metering

    E-Print Network [OSTI]

    Technologie Smart metering Technologie Smart metering 29Bulletin 9/2014 Innovative Dienste mit intelligenten Stromzählern Standby- und Kühlgeräteverbrauch aus Smart-Meter-Daten Smart Meter ermöglichen weit, kommunikationsfähigen Stromzählern, fort. Smart Meter ermöglichen eine effizi- entere Rechnungsstellung, da sie Mess

  19. Electric sales and revenue: 1993

    SciTech Connect (OSTI)

    Not Available

    1995-01-01T23:59:59.000Z

    The Electric Sales and Revenue is prepared by the Survey Management Division, Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); US Department of Energy. This publication provides information about sales of electricity, its associated revenue, and the average revenue per kilowatthour sold to residential, commercial, industrial, and other consumers throughout the United States. The sales, revenue, and average revenue per kilowatthour data provided in the Electric Sales and Revenue are based on annual data reported by electric utilities for the calendar year ending December 31, 1993. Operating revenue includes energy charges, demand charges, consumer service charges, environmental surcharges, fuel adjustments, and other miscellaneous charges. The revenue does not include taxes, such as sales and excise taxes, that are assessed on the consumer and collected through the utility. Average revenue per kilowatthour is defined as the cost per unit of electricity sold and is calculated by dividing retail sales into the associated electric revenue. Because electric rates vary based on energy usage, average revenue per kilowatthour are affected by changes in the volume of sales. The sales of electricity, associated revenue, and average revenue per kilowatthour data provided in this report are presented at the national, Census division, State, and electric utility levels.

  20. Palau- Net Metering

    Broader source: Energy.gov [DOE]

    The Palau Net Metering Act of 2009 established net metering on the Island of Palau. Net metering was implemented in order to:

  1. Electric sales and revenue 1996

    SciTech Connect (OSTI)

    NONE

    1997-12-01T23:59:59.000Z

    Information is provided on electricity sales, associated revenue, average revenue per kilowatthour sold, and number of consumers throughout the US. The data provided in the Electric Sales and Revenue are presented at the national, Census division, State, and electric utility levels. The information is based on annual data reported by electric utilities for the calendar year ending December 31, 1996. 16 figs., 20 tabs.

  2. Capital and revenue expenditures

    E-Print Network [OSTI]

    Owens, Jack Bailey

    1948-01-01T23:59:59.000Z

    T and Charaoteristios of Various Expenditures ~ ~ 7 III. Bases for Expenditure Classifioationi ~ ~ ~ ~ ~ ~ ~ ~ r ~ ' ~ IV ~ Methods of kooountiag for Capital and Revenue Expenditure( ~ ~ I CkPITLL ERE RKVRRUm bXPLM)ITURkiS ISTRORUGTIOR kn ?ttonpt will be made... not tahe tho plass of asy asset or part of aa asset already onistiag Ln a business, but give tho already sainting fined asset ealues an a44ed physioal value whioh they did not previously possess ~ Additions rosoable original oost in that both...

  3. Local Government Revenue Bonds (Montana)

    Broader source: Energy.gov [DOE]

    Limited obligation local government bonds ("special revenue bonds") may be issued for qualified electric energy generation facilities, including those powered by renewables. These bonds generally...

  4. Electric sales and revenue 1994

    SciTech Connect (OSTI)

    NONE

    1995-11-01T23:59:59.000Z

    The Electric Sales and Revenue is prepared by the Coal and Electric Data and Renewables Division; Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); US Department of Energy. Information is provided on electricity sales, associated revenue, average revenue per kilowatthour sold, and number of consumers throughout the United States. The data provided in the Electric Sales and Revenue are presented at the national, Census division, State, and electric utility levels. The information is based on annual data reported by electric utilities for the calendar year ending December 31, 1994.

  5. Electric sales and revenue 1997

    SciTech Connect (OSTI)

    NONE

    1998-10-01T23:59:59.000Z

    The Electric Sales and Revenue is prepared by the Electric Power Division; Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); US Department of Energy. Information is provided on electricity sales, associated revenue, average revenue per kilowatthour sold, and number of consumers throughout the US. The data provided in the Electric Sales and Revenue are presented at the national, Census division, State, and electric utility levels. The information is based on annual data reported by electric utilities for the calendar year ending December 31, 1997. 16 figs., 17 tabs.

  6. Regression analysis of WMATA metering information

    SciTech Connect (OSTI)

    Not Available

    1983-12-01T23:59:59.000Z

    The PEPCO provided a magnetic tape that contained energy usage (pulses) data as given in the PEPCO account. The data had 15-min pulses for 26 traction energy meters which were in operation during 1980. The time span was January 20, 1980, to January 19, 1981. Out of 26 traction metering data provided by PEPCO, 18 meters were in DC, 5 meters were in MD, and 3 meters were in VA jurisdictions. The data were converted into Fortran readable form, using program RU0A09.FOR. The system flow chart is shown. Using A, plots were created of summary statistics, which provided through bar charts information on mean, standard deviation, and maximum of power demand. Using B, regression analyses of power vs. car-miles/hour and degree-days for revenue operating and nonoperating periods were established. Using C, energy consumption histograms on each time period for various meters were created. The regression analysis which was done on PEPCO metering data in order to determine the dependence of traction energy usages on car-miles and daily temperature is described in detail.

  7. Kansas- Net Metering

    Broader source: Energy.gov [DOE]

    Kansas adopted the Net Metering and Easy Connection Act in May 2009 (see K.S.A. 66-1263 through 66-1271), establishing net metering for customers of investor-owned utilities in Kansas. Net metering...

  8. Electrical energy metering use at a large research facility

    SciTech Connect (OSTI)

    Falke, S.S.

    1992-01-01T23:59:59.000Z

    A brief history of electric energy metering at a large research laboratory is presented. Limited orientation on metering of power and energy quantities derived from single dimension magnitudes is introduced. Operation and application of electromechanical watthour demand, solid state single function transducers, analog multifunction, and digital multifunction discussed. Applications for interdepartmental revenue transfer based on energy and power flow, load profiling, system planning, and use as a troubleshooting tool are described. The material is presented in a perspective for persons familiar with protective relaying components, but lacking similar experience in energy metering.

  9. Private Activity Revenue Bonds (Maryland)

    Broader source: Energy.gov [DOE]

    Private Activity Revenue Bonds are available in the form of both taxable bonds and tax-exempt bonds. Both types of bonds provide access to long-term capital markets for fixed asset financing....

  10. arthroplasty replacement: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Replacement of the target module was accomplished using only remote handling tooling and procedures (hands meter of high density concrete The Target Service Bay is...

  11. LADWP- Net Metering (California)

    Broader source: Energy.gov [DOE]

    LADWP allows its customers to net meter their photovoltaic (PV), wind, and hybrid systems with a capacity of not more than one megawatt. LADWP will provide the necessary metering equipment unless...

  12. LADWP- Net Metering

    Broader source: Energy.gov [DOE]

    LADWP allows its customers to net meter their photovoltaic (PV), wind, and hybrid systems with a capacity of not more than one megawatt. LADWP will provide the necessary metering equipment unless...

  13. Progress Energy- Net Metering

    Broader source: Energy.gov [DOE]

    In August 2009, the South Carolina Public Service Commission issued an order mandating net metering be made available by the regulated electric utilities; the order incorporates a net metering...

  14. Net Metering Rules (Arkansas)

    Broader source: Energy.gov [DOE]

    The Net Metering Rules are promulgated under the authority of the Arkansas Public Service Commission. These rules are created to establish rules for net energy metering and interconnection. These...

  15. Duke Energy- Net Metering

    Broader source: Energy.gov [DOE]

    In August 2009, the South Carolina Public Service Commission issued an order mandating net metering be made available by the regulating utilities; the order incorporates a net metering settlement...

  16. Utility Metering- AGL Resources

    Broader source: Energy.gov [DOE]

    Presentation—given at the Spring 2013 Federal Utility Partnership Working Group (FUPWG) meeting—discusses AGL Resources metering, including interruptible rate customers, large users, and meeting federal metering goals.

  17. Electric sales and revenue 1992, April 1994

    SciTech Connect (OSTI)

    Not Available

    1994-04-20T23:59:59.000Z

    The Electric Sales and Revenue is prepared by the Survey Management Division, Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); US Department of Energy. This publication provides information about sales of electricity, its associated revenue, and the average revenue per kilowatthour sold to residential, commercial, industrial, and other consumers throughout the United States. The sales, revenue, and average revenue per kilowatthour provided in the Electric Sales and Revenue are based on annual data reported by electric utilities for the calendar year ending December 31, 1992. The electric revenue reported by each electric utility includes the applicable revenue from kilowatthours sold; revenue from income; unemployment and other State and local taxes; energy, demand, and consumer service charges; environmental surcharges; franchise fees; fuel adjustments; and other miscellaneous charges. The revenue does not include taxes, such as sales and excise taxes, that are assessed on the consumer and collected through the utility. Average revenue per kilowatthour is defined as the cost per unit of electricity sold and is calculated by dividing retail sales into the associated electric revenue. The sales of electricity, associated revenue, and average revenue per kilowatthour provided in this report are presented at the national, Census division, State, and electric utility levels.

  18. Utility-Based Revenue Streams- Notes

    Broader source: Energy.gov [DOE]

    Better Buildings Neighborhood Program October 2011 Workshop Summary of Revenue Streams from Breakout Sessions (11/20/11).

  19. Financial Institution-Based Revenue Streams-- Notes

    Broader source: Energy.gov [DOE]

    Better Buildings Neighborhood Program October 2011 Workshop, Summary of Revenue Streams from Breakout Sessions (11/20/11).

  20. Customer-Based Revenue Streams-- Notes

    Broader source: Energy.gov [DOE]

    Better Buildings Neighborhood Program October 2011 Workshop, Summary of Revenue Streams from Breakout Sessions (11/20/11).

  1. Contractor-Based Revenue Streams-- Notes

    Broader source: Energy.gov [DOE]

    Better Buildings Neighborhood Program October 2011 Workshop, Summary of Revenue Streams from Breakout Sessions (11/20/11).

  2. Local Government-Based Revenue Streams-- Notes

    Broader source: Energy.gov [DOE]

    Better Buildings Neighborhood Program October 2011 Workshop, Summary of Revenue Streams from Breakout Sessions (11/20/11).

  3. Net Energy Metering (NEM)

    Broader source: Energy.gov (indexed) [DOE]

    the Arizona Public Service Co. (APS) request for a charge on future rooftop solar panel installations connected to the grid under the state's net energy metering (NEM)...

  4. Budget/Object Codes -REVENUE Budget/Object Codes -REVENUE BUDGET/OBJECT BUDGET/OBJECT

    E-Print Network [OSTI]

    Selmic, Sandra

    Budget/Object Codes -REVENUE Budget/Object Codes - REVENUE BUDGET/OBJECT BUDGET/OBJECT BUDGET CODE DESCRIPTION BUDGET CODE DESCRIPTION 01 30 0101 On-Campus-Full Time 3001 Federal Program 0102 On APPROPRIATIONS #12;Budget/Object Codes -REVENUE Budget/Object Codes - REVENUE BUDGET/OBJECT BUDGET/OBJECT BUDGET

  5. DC attenuation meter

    DOE Patents [OSTI]

    Hargrove, Douglas L.

    2004-09-14T23:59:59.000Z

    A portable, hand-held meter used to measure direct current (DC) attenuation in low impedance electrical signal cables and signal attenuators. A DC voltage is applied to the signal input of the cable and feedback to the control circuit through the signal cable and attenuators. The control circuit adjusts the applied voltage to the cable until the feedback voltage equals the reference voltage. The "units" of applied voltage required at the cable input is the system attenuation value of the cable and attenuators, which makes this meter unique. The meter may be used to calibrate data signal cables, attenuators, and cable-attenuator assemblies.

  6. PSEG Long Island- Net Metering

    Broader source: Energy.gov [DOE]

    Although PSEG Long Island’s net metering policy is not governed by the State’s net metering law, the provisions are similar to the State law. Net metering is available for residential, non-reside...

  7. Guam- Net Metering

    Broader source: Energy.gov [DOE]

    Guam's Public Utilities Commission (PUC) reviewed net metering and interconnection during a regular meeting in February 2009 (Docket 08-10). Please contact the [http://www.guampuc.com/ Guam PUC]...

  8. Net Metering (Ontario, Canada)

    Broader source: Energy.gov [DOE]

    Ontario's net metering regulation allows you to send electricity generated from renewable sources to the electrical grid for a credit toward your energy costs. Here's how it works. Your utility...

  9. Puerto Rico- Net Metering

    Broader source: Energy.gov [DOE]

    Puerto Rico enacted net-metering legislation in August 2007, allowing customers of Puerto Rico Electric Power Authority (PREPA) to use electricity generated by solar, wind or "other" renewable...

  10. Economics of Energy Metering

    E-Print Network [OSTI]

    Duncan, J. D.

    1979-01-01T23:59:59.000Z

    become necessary to accurately measure energy usage (primarily fuel and steam) throughout the plant. There are currently several projects in the million dollar range to upgrade and add new metering to these flows. This paper will discuss the justification...

  11. Avista Utilities- Net Metering

    Broader source: Energy.gov [DOE]

    Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has developed a net...

  12. Ashland Electric- Net Metering

    Broader source: Energy.gov [DOE]

    In 1996, Ashland adopted a net-metering program that includes simple interconnection guidelines. The program encourages the adoption of renewable-energy systems by committing the city to purchase,...

  13. Idaho Power- Net Metering

    Broader source: Energy.gov [DOE]

    Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has developed a net...

  14. Washington City Power- Net Metering

    Broader source: Energy.gov [DOE]

    Washington City adopted a net-metering program, including interconnection procedures, in January 2008.* Net metering is available to residential and commercial customers that generate electricity...

  15. Tax-Exempt Industrial Revenue Bonds (Kansas)

    Broader source: Energy.gov [DOE]

    Tax-Exempt Industrial Revenue Bonds are issued by cities and counties for the purchase, construction, improvement or remodeling of a facility for agricultural, commercial, hospital, industrial,...

  16. Neutron dose equivalent meter

    DOE Patents [OSTI]

    Olsher, Richard H. (Los Alamos, NM); Hsu, Hsiao-Hua (Los Alamos, NM); Casson, William H. (Los Alamos, NM); Vasilik, Dennis G. (Los Alamos, NM); Kleck, Jeffrey H. (Menlo Park, CA); Beverding, Anthony (Foster City, CA)

    1996-01-01T23:59:59.000Z

    A neutron dose equivalent detector for measuring neutron dose capable of accurately responding to neutron energies according to published fluence to dose curves. The neutron dose equivalent meter has an inner sphere of polyethylene, with a middle shell overlying the inner sphere, the middle shell comprising RTV.RTM. silicone (organosiloxane) loaded with boron. An outer shell overlies the middle shell and comprises polyethylene loaded with tungsten. The neutron dose equivalent meter defines a channel through the outer shell, the middle shell, and the inner sphere for accepting a neutron counter tube. The outer shell is loaded with tungsten to provide neutron generation, increasing the neutron dose equivalent meter's response sensitivity above 8 MeV.

  17. Energy Metering Audit Procedure

    E-Print Network [OSTI]

    Whitaker, W. S.

    Energy Meterilg Audtt Procedure Wiliam S Whitaker Engineering Specialist T X E INC. laPorte Texas INTROOUCI'ION This paper describes the recent audit of the utility distriooticn meters in a petrochanica1 plant. These meters measure the steam... audit Will also identify losses in the distriooticn eMrtem itself. '!he results of the audit can be used to recx:umand charYJes in operatin] procedures ~th respect to energy soorces. In aci:iiticn, ,the audit oou1d \\.Il'1COVer prob1ans...

  18. atlanto-odontoid joint replacement: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Replacement of the target module was accomplished using only remote handling tooling and procedures (hands meter of high density concrete The Target Service Bay is...

  19. Elbow mass flow meter

    DOE Patents [OSTI]

    McFarland, Andrew R. (College Station, TX); Rodgers, John C. (Santa Fe, NM); Ortiz, Carlos A. (Bryan, TX); Nelson, David C. (Santa Fe, NM)

    1994-01-01T23:59:59.000Z

    Elbow mass flow meter. The present invention includes a combination of an elbow pressure drop generator and a shunt-type mass flow sensor for providing an output which gives the mass flow rate of a gas that is nearly independent of the density of the gas. For air, the output is also approximately independent of humidity.

  20. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    81 Residential Sales (MWh) 647 Residential Consumers 290 Commercial Revenue(Thousand ) 168.985 Commercial Sales (MWh) 2306 Commercial Consumers 81 Industrial Revenue (Thousand )...

  1. 4-County Electric Power Assn (Mississippi) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Residential Revenue(Thousand ) 5629 Residential Sales (MWh) 49312 Residential Consumers 35980 Commercial Revenue(Thousand ) 2031 Commercial Sales (MWh) 15395 Commercial Consumers...

  2. N. Mariana Islands- Net Metering

    Broader source: Energy.gov [DOE]

    Note: The Commonwealth Utility Corporation issued a moratorium on net metering. However, Public Law 18-62 signed September 6, 2014 states that net metering should be available to all residential...

  3. Rocky Mountain Power- Net Metering

    Broader source: Energy.gov [DOE]

    Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has a net-metering...

  4. SCE&G- Net Metering

    Broader source: Energy.gov [DOE]

    In August 2009, the South Carolina Public Service Commission issued an order mandating net metering be made available by the regulated electric utilities; the order incorporates a net metering...

  5. EPAct 2005 Metering Guidance Overview

    Office of Environmental Management (EM)

    * Agency policiesguidance Potential Roles for Utilities * Guidanceupdates on time-based pricing * Metering services * Finance installations * Other? Useful Documents * Guidance...

  6. Industrial Revenue Bond Issuance Cost Assistance (Wisconsin)

    Broader source: Energy.gov [DOE]

    Industrial Revenue Bonds (IRB) are tax-exempt bonds that can be used to stimulate capital investment and job creation by providing private borrowers with access to financing at interest rates that...

  7. Revenue impacts of airline yield management

    E-Print Network [OSTI]

    Mak, Chung Yu

    1992-01-01T23:59:59.000Z

    In the highly competitive airline industry today, Yield or Revenue Management is extremely important to the survival of any carrier. Since fares are generally matched by all carriers to be competitive, the ability of an ...

  8. Cargo revenue management for space logistics

    E-Print Network [OSTI]

    Armar, Nii A

    2009-01-01T23:59:59.000Z

    This thesis covers the development of a framework for the application of revenue management, specifically capacity control, to space logistics for use in the optimization of mission cargo allocations, which in turn affect ...

  9. Hydrostatic bearings for a turbine fluid flow metering device

    DOE Patents [OSTI]

    Fincke, James R. (Rigby, ID)

    1982-01-01T23:59:59.000Z

    A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion.

  10. Hydrostatic bearings for a turbine fluid flow metering device

    DOE Patents [OSTI]

    Fincke, J.R.

    1982-05-04T23:59:59.000Z

    A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion. 3 figs.

  11. Portable wastewater flow meter

    DOE Patents [OSTI]

    Hunter, Robert M. (320 S. Wilson Ave., Bozeman, MT 59715)

    1990-01-01T23:59:59.000Z

    A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under full pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

  12. Portable wastewater flow meter

    DOE Patents [OSTI]

    Hunter, Robert M. (320 S. Wilson Ave., Bozeman, MT 59715)

    1999-02-02T23:59:59.000Z

    A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under fill pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

  13. Employee Replacement Costs

    E-Print Network [OSTI]

    Dube, Arindrajit; Freeman, Eric; Reich, Michael

    2010-01-01T23:59:59.000Z

    Employee Replacement Costs Arindrajit Dube, Eric Freeman andproperties of employee replacement costs, using a panel2008. We establish that replacement costs are sub- stantial

  14. O&M Metering Guidance

    Broader source: Energy.gov [DOE]

    Presentation covers the O&M Metering Guidance and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Rapid City, South Dakota.

  15. Net Metering (New Brunswick, Canada)

    Broader source: Energy.gov [DOE]

    The NB Power Net Metering program provides customers with the option to connect their own environmentally sustainable generation unit to NB Power's distribution system. The program allows customers...

  16. Electric Metering | Department of Energy

    Energy Savers [EERE]

    The Forrestal electric meters provide daily read-outs and comparison of data on electricity consumption for overhead lighting and power outlets. The purpose is to measure...

  17. Impact of orifice metering uncertainties

    SciTech Connect (OSTI)

    Stuart, J.W. (Pacific Gas and Electric Co., San Francisco, CA (USA))

    1990-12-01T23:59:59.000Z

    In a recent utility study, attributed 38% of its unaccounted-for UAF gas to orifice metering uncertainty biasing caused by straightening vanes. How this was determined and how this applied to the company's orifice meters is described. Almost all (97%) of the company's UAF gas was found to be attributed to identifiable accounting procedures, measurement problems, theft and leakage.

  18. Revenue Management: Research Overview and Prospects

    E-Print Network [OSTI]

    research directions. The survey includes a glossary of revenue management terminology and a bibliography for the survey to follow. More detailed accounts of the origins of rev- enue management can be found in BELOBABARevenue Management: Research Overview and Prospects JEFFREY I. MCGILL Queen's University, School

  19. Single-Issue Industrial Revenue Bond Program (Missouri)

    Broader source: Energy.gov [DOE]

    The Missouri Development Finance Board administers a Single-Issue Tax-Exempt Industrial Revenue Bond Program as well as a Taxable Industrial Revenue Bond Program. The Tax-Exempt Program finances (i...

  20. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    8 Jump to: navigation, search EIA Monthly Electric Utility Sales and Revenue Data for Ak-Chin Electric Utility Authority for March 2008. Monthly Electric Utility Sales and Revenue...

  1. Efficiency of (Revenue-)Optimal Mechanisms Gagan Aggarwal

    E-Print Network [OSTI]

    Tomkins, Andrew

    Efficiency of (Revenue-)Optimal Mechanisms Gagan Aggarwal Google Inc. Mountain View, CA gagana aranyak@google.com ABSTRACT We compare the expected efficiency of revenue maximizing (or optimal) mechanisms with that of efficiency maximizing ones. We show that the efficiency of the revenue maximizing

  2. Employee Replacement Costs

    E-Print Network [OSTI]

    Dube, Arindrajit; Freeman, Eric; Reich, Michael

    2010-01-01T23:59:59.000Z

    Samuel Schenker, “The Costs of Hir- u ing Skilled Workers”,Employee Replacement Costs Arindrajit Dube, Eric Freeman andof employee replacement costs, using a panel survey of

  3. Design of high pressure metering and regulating stations

    SciTech Connect (OSTI)

    Rehler, D.A. [Oklahoma Natural Gas Co., Enid, OK (United States)

    1995-12-01T23:59:59.000Z

    Metering and regulating stations effectively serve as the cash registers of the natural gas industry. While the potential for lost revenue resulting from improper design is a serious consideration, it is not the only one. The potential exists for problems such as excessive noise levels, inaccurate reflection of lost and unaccounted-for gas, and numerous potentially hazardous situations. The best time to limit the potential for problems is during the design process. This, together with the critical nature of these stations, dictates that proper design is imperative. Proper design of metering and regulating stations is a constantly changing and extremely complicated subject. There are virtually an infinite number of situations that the designer can encounter in evaluating his design. In view of this, it is impossible to develop a cookbook method of designing these stations that covers all possible situations. The emphasis of this paper is to briefly touch on the major aspects of metering and regulating station design. Steps involved in station design are: 1. Collection of data on the proposed station. 2. Determination of piping configuration. 3. Selection of measurement equipment. 4. Selection of pressure regulating and overpressure protection equipment. 5. Communication of the final design to field personnel.

  4. Hydrostatic bearings for a turbine fluid flow metering device

    DOE Patents [OSTI]

    Fincke, J.R.

    1980-05-02T23:59:59.000Z

    A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion.

  5. Valley Electric Association- Net Metering

    Broader source: Energy.gov [DOE]

    The Board of Directors for Valley Electric Association (VEA) approved net metering in April 2008. The rules apply to systems up to 30 kW, though owners of larger systems may be able to negotiate...

  6. Electric Metering | Department of Energy

    Energy Savers [EERE]

    has installed meters in the James Forrestal Building that will enable DOE to measure electricity use and costs in its headquarters facility. You may explore this data further by...

  7. Austin Energy- Net Metering (Texas)

    Broader source: Energy.gov [DOE]

    Austin Energy, the municipal utility of Austin Texas, offers net metering for renewable energy systems up to 20 kilowatts (kW) to its non-residential retail electricity customers. The definition of...

  8. Healthcare Energy Metering Guidance (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2011-07-01T23:59:59.000Z

    This brochure is intended to help facility and energy managers plan and prioritize investments in energy metering. It offers healthcare-specific examples of metering applications, benefits, and steps that other health systems can reproduce. It reflects collaborative input from the U.S. Department of Energy national laboratories and the health system members of the DOE Hospital Energy Alliance's Benchmarking and Measurement Project Team.

  9. Gamma radiation field intensity meter

    DOE Patents [OSTI]

    Thacker, L.H.

    1994-08-16T23:59:59.000Z

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode. 4 figs.

  10. Gamma radiation field intensity meter

    DOE Patents [OSTI]

    Thacker, Louis H. (Knoxville, TN)

    1995-01-01T23:59:59.000Z

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode.

  11. Gamma radiation field intensity meter

    DOE Patents [OSTI]

    Thacker, L.H.

    1995-10-17T23:59:59.000Z

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode. 4 figs.

  12. Gamma radiation field intensity meter

    DOE Patents [OSTI]

    Thacker, Louis H. (Knoxville, TN)

    1994-01-01T23:59:59.000Z

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode.

  13. First SNS Target Replacement

    E-Print Network [OSTI]

    McDonald, Kirk

    First SNS Target Replacement Experience M. Dayton, M. Rennich, Van Graves, J. DeVore Presented by T.S. Department of Energy AHIP Workshop Oct. 2009 Overview · Initial Target Replacement · Target Maintenance-Battelle for the U.S. Department of Energy AHIP Workshop Oct. 2009 First SNS Target Replacement · Replacement

  14. Plug-in privacy for Smart Metering billing

    E-Print Network [OSTI]

    Jawurek, Marek; Kerschbaum, Florian

    2010-01-01T23:59:59.000Z

    Smart Metering is a concept that allows to collect fine-grained consumption profiles from customers by replacing traditional electricity meters with Smart Meters in customers' households. The recorded consumption profile is the basis for the calculation of time-dependent tariffs but also allows deduction of the inhabitant's personal schedules and habits. The current reporting of such consumption profiles only protects this data from 3rd parties but falls short to protect the customer's privacy from illegitimate abuse by the supplier itself. We propose a privacy-preserving profile reporting protocol that enables billing for time-dependent tariffs without disclosing the actual data of the consumption profile to the supplier. Our approach relies on a zero-knowledge proof based on Pedersen Commitments performed by a plug-in privacy component that is put into the communication link between Smart Meter and supplier's back-end systems and requires no change to Smart Meter hardware and only little change to the softw...

  15. 2013 Non-Utility Power Producers- Revenue

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at Commercial andSeptember 25,9,1996 N Y M E2003 Detailed35Revenue

  16. Revenue From Contractor Fees | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingofRetrofitting Doors on OpenRevenue From Contractor

  17. 2013 Revenue for Delivery Service Providers

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghurajiConventionalMississippi" ,"Plant","Primary1. TotalRevenue for Delivery Service

  18. Energy Replacement Generation Tax Exemption

    Broader source: Energy.gov [DOE]

    Under the Energy Replacement Generation Tax Exemption, the following facilities are exempt from the replacement tax:

  19. Precision metering of germinated seeds

    E-Print Network [OSTI]

    Elliot, Gregory Lawrence

    1990-01-01T23:59:59.000Z

    actuated by an electrical solenoid was used to mechanically capture individual seeds. Air was used to eject the seeds from the system. A new single file device employing dilution flow was tested at rates as high as ten seeds per second. It produced... distribution was found to adequately represent the data. The metering system was tested at ejection rates ranging from 1. 3 to 4. 5 seeds per second, with most tests at rates between two and three seeds per second. The performance of the metering system...

  20. Improved integrating cavity absorption meter

    E-Print Network [OSTI]

    Cui, Liqiu

    2000-01-01T23:59:59.000Z

    dependencies on the fiber and detector spectral responses. Dividing Eq. (3. 14) by CiSO, S, C, replacing ? ' by S, and replacing ? ' by C, gives a simple equation that is linear in S, So C, o; and V: S = ? aV+C 4 C 1 (3. 15) We can easily solve...

  1. Analyzing Replacement Stock Alternatives

    E-Print Network [OSTI]

    Falconer, Lawrence; McGrann, James M.; Parker, John; Jones, Rodney

    2008-10-21T23:59:59.000Z

    Replacement management strategy involves comparing the values of the breeding stock you own with the value of potential replacements, and then choosing the investment with the highest expected worth. This publication discusses the application...

  2. Tracking and Using Data to Support Revenue Streams | Department...

    Energy Savers [EERE]

    Documents & Publications Lender-Based Revenues and Cost-Savings Trends in Contractor Conversion Rates Better Buildings Residential Network: Lessons Learned: Peer Exchange Calls...

  3. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    Sales (MWh) 1889 Total Consumers 417 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  4. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 89442.402 Total Consumers 30374 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  5. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 93116.915 Total Consumers 30297 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  6. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 90111.278 Total Consumers 30445 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  7. 4-County Electric Power Assn (Mississippi) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 97102 Total Consumers 44394 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  8. 4-County Electric Power Assn (Mississippi) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 77157 Total Consumers 43869 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  9. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    Sales (MWh) 1777 Total Consumers 417 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  10. 4-County Electric Power Assn (Mississippi) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 69154 Total Consumers 43876 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  11. 4-County Electric Power Assn (Mississippi) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 77543 Total Consumers 44730 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  12. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 89735.352 Total Consumers 30544 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  13. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 107731.895 Total Consumers 30210 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  14. 4-County Electric Power Assn (Mississippi) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 92113 Total Consumers 44586 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  15. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 89390.873 Total Consumers 30381 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  16. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 95905.285 Total Consumers 30205 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  17. 4-County Electric Power Assn (Mississippi) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 64724 Total Consumers 44708 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  18. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    Sales (MWh) 1656 Total Consumers 417 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  19. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    Sales (MWh) 1588 Total Consumers 416 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  20. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 110168.666 Total Consumers 30225 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  1. Central Illinois Pub Serv Co (Illinois) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 723681 Total Consumers 388107 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  2. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 97302.646 Total Consumers 30310 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  3. Central Illinois Pub Serv Co (Illinois) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 635952 Total Consumers 375832 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  4. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    Sales (MWh) 2604 Total Consumers 416 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  5. 4-County Electric Power Assn (Mississippi) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 87721 Total Consumers 43779 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  6. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    Sales (MWh) 1786 Total Consumers 416 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  7. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 106052.325 Total Consumers 30249 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  8. 4-County Electric Power Assn (Mississippi) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 88236 Total Consumers 44787 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  9. Central Illinois Pub Serv Co (Illinois) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 458221 Total Consumers 378624 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  10. 4-County Electric Power Assn (Mississippi) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 73805 Total Consumers 44830 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  11. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 86664.25 Total Consumers 30409 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  12. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 103478.845 Total Consumers 30233 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  13. 4-County Electric Power Assn (Mississippi) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 93756 Total Consumers 43814 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  14. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    Sales (MWh) 2434 Total Consumers 416 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  15. Anchorage Municipal Light and Power (Alaska) EIA Revenue and...

    Open Energy Info (EERE)

    (MWh) 90071.242 Total Consumers 30468 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  16. Assessing Revenue Streams: What Is Right for Your Program? |...

    Broader source: Energy.gov (indexed) [DOE]

    Program Sustainability Peer Exchange Call: Assessing Revenue Streams: What is Right for Your Program? Call Slides and Summary, January 10, 2013, The purpose of this call was to...

  17. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    August 2008 Jump to: navigation, search EIA Monthly Electric Utility Sales and Revenue Data for Ak-Chin Electric Utility Authority for August 2008. Monthly Electric Utility Sales...

  18. Metered Rack PDU The American Power Conversion (APC) Metered

    E-Print Network [OSTI]

    van Hemmen, J. Leo

    StruXureManager interfaces. Outlets. The Rack PDU has twenty (20) IEC-320-C13 outlets and four (4) IEC-320-C19 outlets. The 10-foot (3.05-meter) power cord terminates with a IEC-309 32 A connector. AP7853 #12;*990-1898-001* 990-1898-001 08/2004 Specifications for AP7853 Electrical Input connector IEC-309 32 A plug Output

  19. Cargo Revenue Management for Space Logistics Nii A. Armar

    E-Print Network [OSTI]

    de Weck, Olivier L.

    Cargo Revenue Management for Space Logistics by Nii A. Armar B.S., Aerospace Engineering for Space Logistics by Nii A. Armar Submitted to the Department of Aeronautics and Astronautics on November of revenue management, specifically capacity control, to space logistics for use in the optimization

  20. Meters

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cnHighand Retrievals from aRodMIT-Harvard Center forMetallicH. Skinner,sc 620

  1. Meters

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated Codes |IsLove Your HomeOverview and HistoryMEMS: Inside theand RP-1

  2. Government Program Briefing: Smart Metering

    Office of Energy Efficiency and Renewable Energy (EERE)

    This document is adapted and updated from a memo delivered to the City Council of New Orleans, the office of the Mayor of New Orleans, the Chairperson of the Citizen Stakeholders Group (New Orleans Energy Task Force) and the U.S. Department of Energy (DOE) Project Officer in March 2008. This briefing piece provides an overview of the benefits, costs, and challenges of smart metering.

  3. Government Program Briefing: Smart Metering

    SciTech Connect (OSTI)

    Doris, E.; Peterson, K.

    2011-09-01T23:59:59.000Z

    This document is adapted and updated from a memo delivered to the City Council of New Orleans, the office of the Mayor of New Orleans, the Chairperson of the Citizen Stakeholders Group (New Orleans Energy Task Force) and the U.S. Department of Energy (DOE) Project Officer in March 2008. This briefing piece provides an overview of the benefits, costs, and challenges of smart metering.

  4. Heating Energy Meter Validation for Apartments

    E-Print Network [OSTI]

    Cai, B.; Li, D.; Hao, B.

    2006-01-01T23:59:59.000Z

    Household heat metering is the core of heating system reform. Because of many subjective and objective factors, household heat metering has not been put into practice to a large extent in China. In this article, the research subjects are second...

  5. Heating Energy Meter Validation for Apartments 

    E-Print Network [OSTI]

    Cai, B.; Li, D.; Hao, B.

    2006-01-01T23:59:59.000Z

    Household heat metering is the core of heating system reform. Because of many subjective and objective factors, household heat metering has not been put into practice to a large extent in China. In this article, the research subjects are second...

  6. Long Island Power Authority- Net Metering

    Broader source: Energy.gov [DOE]

    : Note: In October 2012 the LIPA Board of Trustees adopted changes to the utility's net metering tariff that permit remote net metering for non-residential solar and wind energy systems, and farm...

  7. City of St. George- Net Metering

    Broader source: Energy.gov [DOE]

    The St. George City Council adopted a [http://www.sgcity.org/wp/power/NetMeteringPolicy.pdf net-metering program for area utilities], including interconnection procedures, in October 2005.* The...

  8. Privacy-Preserving Smart Metering Alfredo Rial

    E-Print Network [OSTI]

    Bernstein, Phil

    Privacy-Preserving Smart Metering Alfredo Rial K.U.Leuven, ESAT/COSIC & IBBT Leuven, Belgium General Terms Security Keywords Billing, Smart metering, Cryptographic Protocol, Verifiable Computing 1 of smart meter data for more accurate forecasting, Permission to make digital or hard copies of all or part

  9. PQMII POWER QUALITY METER INSTRUCTION MANUAL 11 PQMII Power Quality Meter

    E-Print Network [OSTI]

    Meyers, Steven D.

    #12;#12;#12;PQMII POWER QUALITY METER ­ INSTRUCTION MANUAL 1­1 PQMII Power Quality Meter Chapter 1 Multilin PQMII Power Quality Meter is an ideal choice for continuous monitoring of a single or three-phase system. It provides metering for current, voltage, real power, reactive power, apparent power, energy use

  10. Radiation Source Replacement Workshop

    SciTech Connect (OSTI)

    Griffin, Jeffrey W.; Moran, Traci L.; Bond, Leonard J.

    2010-12-01T23:59:59.000Z

    This report summarizes a Radiation Source Replacement Workshop in Houston Texas on October 27-28, 2010, which provided a forum for industry and researchers to exchange information and to discuss the issues relating to replacement of AmBe, and potentially other isotope sources used in well logging.

  11. Electric Metering | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you sure you want toworldPowerHome | Documents MemorandumEEOElectric Metering

  12. Discussion series on PURPA related topics: metering

    SciTech Connect (OSTI)

    Sturgeon, J I

    1980-08-01T23:59:59.000Z

    Time-differentiated metering of electricity consumption and demand is required in both rate-structure experimentation and the implementation of most time-of-use rate designs. Time-differentiated metering takes three major forms: multi-register watthour meters, magnetic-tape recording meters, and remote automatic meter-reading systems. The majority of projects selected magnetic-tape meters for their flexibility with respect to rate structure, load-survey capabilities, and ready availability. The small-scale, experimental nature of the projects reduced the significance of the large difference in per-unit cost and operational/maintenance complexity between this form of metering and the multi-register form. Magnetic-tape meters are not likely candidates for system-wide implementation of time-differentiated metering. Automatic remote-meter-reading systems were not adequately available during the project years; those projects attempting to use these were unable to bring them to full operational status before project termination, due to the many problems of design, quality control, and equipment acquisition encountered. Delays in acquisition and problems of quality control also followed the selection of magnetic-tape meters and multi-register meters by a number of the projects. Though less complex than automatic remote-reading systems, these technologies are still new and more complex than standard watthour metering. Thus, both equipment vendors and utilities encountered numerous problems in getting properly functioning meters to the service entrances on time. A variety of factors contributed to installation delays, including unforeseen space limitations, incompatible wiring, problems of task organization, and customer reluctance.

  13. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    January 2008. Monthly Electric Utility Sales and Revenue Data Short Name 2008-01 Utility Company Ak-Chin Electric Utility Authority (Arizona) Place Arizona Start Date 2008-01-01...

  14. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    April 2008 Jump to: navigation, search EIA Monthly Electric Utility Sales and Revenue Data for Ak-Chin Electric Utility Authority for April 2008. Monthly Electric Utility Sales and...

  15. Ak-Chin Electric Utility Authority (Arizona) EIA Revenue and...

    Open Energy Info (EERE)

    December 2008. Monthly Electric Utility Sales and Revenue Data Short Name 2008-12 Utility Company Ak-Chin Electric Utility Authority (Arizona) Place Arizona Start Date 2008-12-01...

  16. New approaches for integrating revenue and supply chain management

    E-Print Network [OSTI]

    Elmachtoub, Adam Nabil

    2014-01-01T23:59:59.000Z

    First, we describe a general framework called online customer selection that describes natural settings where suppliers must actively select which customer requests to serve. Unlike traditional revenue management models ...

  17. activity meters: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Dienste mit intelligenten Stromzhlern Standby- und Khlgerteverbrauch aus Smart-Meter-Daten Smart Meter ermglichen weit, kommunikationsfhigen...

  18. Diploma Replacement Order diploma-replace 1/12

    E-Print Network [OSTI]

    Shamos, Michael I.

    Diploma Replacement Order diploma-replace 1/12 A replacement diploma may be ordered in the event of loss of or damage to the original diploma. Replacement diplomas are 17Ã? 14 ("mini" diplomas or letter-sized diplomas are no longer available). The replacement diploma fee is $50, payable by check or credit card

  19. Video face replacement

    E-Print Network [OSTI]

    Dale, Kevin

    We present a method for replacing facial performances in video. Our approach accounts for differences in identity, visual appearance, speech, and timing between source and target videos. Unlike prior work, it does not ...

  20. Farmington Electric Utility System- Net Metering

    Broader source: Energy.gov [DOE]

    Net metering rules developed by the New Mexico Public Regulation Commission (PRC) apply to the state's investor-owned utilities and electric cooperatives. Municipal utilities, which are not...

  1. Ellsworth Air Force Base Advanced Metering Project

    Broader source: Energy.gov [DOE]

    Presentation covers the Ellsworth Air Force Base Advanced Metering project and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

  2. REQUEST FOR REPLACEMENT DIPLOMA Name: ________________________________________________________________________

    E-Print Network [OSTI]

    Gering, Jon C.

    REQUEST FOR REPLACEMENT DIPLOMA Name. ________________________________________________________________________ First Middle Maiden Last REPLACEMENT DIPLOMA INFORMATION Please print your name exactly as you want it to appear on your replacement diploma. If your name has changed since your degree was awarded, and if you

  3. Assessment of Demand Response and Advanced Metering

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    #12;#12;2008 Assessment of Demand Response and Advanced Metering Staff Report Federal Energy metering penetration and potential peak load reduction from demand response have increased since 2006. Significant activity to promote demand response or to remove barriers to demand response occurred at the state

  4. Proton recoil scintillator neutron rem meter

    DOE Patents [OSTI]

    Olsher, Richard H. (Los Alamos, NM); Seagraves, David T. (Los Alamos, NM)

    2003-01-01T23:59:59.000Z

    A neutron rem meter utilizing proton recoil and thermal neutron scintillators to provide neutron detection and dose measurement. In using both fast scintillators and a thermal neutron scintillator the meter provides a wide range of sensitivity, uniform directional response, and uniform dose response. The scintillators output light to a photomultiplier tube that produces an electrical signal to an external neutron counter.

  5. automated seepage meters: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Index 1 An Overview on Advance Metering System CiteSeer Summary: Abstract The term "Smart meter " typically refers to an electrical meter, but the term is also starting to be...

  6. Working With Your Utility to Obtain Metering Services

    Broader source: Energy.gov [DOE]

    Presentation—given at the Spring 2013 Federal Utility Partnership Working Group (FUPWG) meeting—covers the government metering requirement, the U.S. Department of Defense (DoD) metering directive, and customer metering services available from utilities.

  7. Portable Liquid Flow Metering for Energy Conservation Programs

    E-Print Network [OSTI]

    Miles, F. J.

    1982-01-01T23:59:59.000Z

    Flow metering is absolutely required for evaluation of energy usage. In fact, determining usages and heat balances without metering are simply educated guesses. Recent technological innovations in flow metering have produced clamp-on, portable flow...

  8. U.S. Virgin Islands- Net Metering

    Broader source: Energy.gov [DOE]

    In February 2007, the U.S. Virgin Islands Public Services Commission approved a limited net-metering program for residential and commercial photovoltaic (PV), wind-energy or other renewable energ...

  9. Murray City Power- Net Metering Pilot Program

    Broader source: Energy.gov [DOE]

    Under a pilot program, Murray City Power offers net metering to customers that generate electricity using photovoltaic (PV), wind-electric or hydroelectric systems with a maximum capacity of 10...

  10. BPA Metering Services Editing and Estimating Procedures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    be used to scale the estimated interval data with a shape projection applied. If SCADA data is available and has been mapped to the point of metering, it may be used for...

  11. Advanced metering techniques in the federal sector

    SciTech Connect (OSTI)

    Szydlowski, R.F.; Chvala, W.D. Jr.; Halverson, M.A.

    1994-12-01T23:59:59.000Z

    The lack of utility metering in the federal sector has hampered introduction of direct billing of individual activities at most military installations. Direct billing will produce accountability for the amount of energy used and is a positive step toward self-directed energy conservation. For many installations, automatic meter reading (AMR) is a cost-effective way to increase the number of meters while reducing labor requirements and providing energy conservation analysis capabilities. The communications technology used by some of the AMR systems provides other demand-side management (DSM) capabilities. This paper summarizes the characteristics and relative merits of several AMR/DSM technologies that may be appropriate for the federal sector. A case study of an AMR system being installed at Fort Irwin, California, describes a cost-effective two-way radio communication system used for meter reading and load control.

  12. Hydro-Québec Net Metering (Quebec, Canada)

    Broader source: Energy.gov [DOE]

    In line with Hydro-Québec's commitment to the environment and sustainable development, Hydro-Québec is supporting self-generation with a new rate offering: the net metering option. This option...

  13. City of New Orleans- Net Metering

    Broader source: Energy.gov [DOE]

    In May 2007, the New Orleans City Council adopted net-metering rules that are similar to rules adopted by the Louisiana Public Service Commission (PSC) in November 2005. The City Council's rules...

  14. Revenue Management for Cognitive Spectrum Underlay Networks: An Interference Elasticity

    E-Print Network [OSTI]

    Huang, Jianwei

    to the large body of work on uplink power control with pricing for CDMA networks (e.g., [5]­[10] and a recent a total received interference power constraint at the primary user's receiver. The transmission power1 Revenue Management for Cognitive Spectrum Underlay Networks: An Interference Elasticity

  15. Classifying Web Search Queries to Identify High Revenue Generating Customers

    E-Print Network [OSTI]

    Jansen, James

    searching, the set of terms for which a user searches is called the query. If a user enters a query and then clicks on a result, these query terms are embedded within the URL that is passed from the search engineClassifying Web Search Queries to Identify High Revenue Generating Customers Adan Ortiz-Cordova 329

  16. Total revenues up, profits down for OGJ400

    SciTech Connect (OSTI)

    Beck, R.J.; Biggs, J.B.

    1990-10-08T23:59:59.000Z

    After moving up sharply the previous 2 years, profits for the biggest 400 U.S. public oil and gas companies sagged in fiscal 1989. The total: $20.34 billion, down 8.6% from 1988. Revenues, however, gained 6.1% to $459.2 billion. Company-by-company financial results and operating statistics appear in this report.

  17. Equitable Carbon Revenue Distribution Under an International Emissions

    E-Print Network [OSTI]

    Kammen, Daniel M.

    No. 5 Equitable Carbon Revenue Distribution Under an International Emissions Trading Regime Nathan an International Emissions Trading Regime Nathan E. Hultman and Daniel M. Kammen Energy & Resources Group Goldman emissions have started but may not be completely felt for 100 years or more.2 The long-term nature

  18. Solutia: Utilizing Sub-Metering to Drive Energy Project Approvals...

    Broader source: Energy.gov (indexed) [DOE]

    plant. Solutia: Utilizing Sub-Metering to Drive Energy Project Approvals Through Data (July 2011) More Documents & Publications Nissan North America: How Sub-Metering...

  19. LM to Meet Energy Metering Goals Through Enhanced Data Collection...

    Office of Environmental Management (EM)

    to Meet Energy Metering Goals Through Enhanced Data Collection at Groundwater Treatment Systems LM to Meet Energy Metering Goals Through Enhanced Data Collection at Groundwater...

  20. Metering Best Practices: A Guide to Achieving Utility Resource...

    Office of Environmental Management (EM)

    Metering Best Practices: A Guide to Achieving Utility Resource Efficiency Metering Best Practices: A Guide to Achieving Utility Resource Efficiency Guide describes information...

  1. Non-linear revenue creating business platform for IT service companies using cloud computing

    E-Print Network [OSTI]

    Sinha, Prasanta, S.M. Massachusetts Institute of Technology

    2012-01-01T23:59:59.000Z

    The Indian Information Technology (IT) & Business process outsourcing (BPO) companies are going through an inflection point. They have been growing revenue by over 20% on a yearly basis for the last decade. This revenue ...

  2. The Politics of Revenue-Raising Tax Reform in Latin America

    E-Print Network [OSTI]

    Fairfield, Tasha

    2010-01-01T23:59:59.000Z

    spending-side benefits. The proposal destined revenue from the royalty to a new research and development

  3. Tax-versus-trading and efficient revenue recycling as issues for greenhouse gas abatement

    E-Print Network [OSTI]

    Pezzey, Jack

    Tax-versus-trading and efficient revenue recycling as issues for greenhouse gas abatement Final://people.anu.edu.au/jack.pezzey (J.C.V. Pezzey) Keywords: emission pricing, tax-versus-trading, uncertainties, revenue recycling, and revenue recycling. Including multiple, independent parties greatly reduces the welfare advantage

  4. A Scalable Communication Architecture for Advanced Metering Infrastructure

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    , Communication Architecture, Inter-connecting Overlays. I. INTRODUCTION In AMI system, smart meters measure of data is collected from each smart meter every 15 minutes [Bernaudo et al 2010]. In addition, meter data, the connection from the MDMSs to smart meters following the client-server model as normally to be compatible

  5. Monitoring Massive Appliances by a Minimal Number of Smart Meters

    E-Print Network [OSTI]

    Wang, Yongcai

    56 Monitoring Massive Appliances by a Minimal Number of Smart Meters YONGCAI WANG, XIAOHONG HAO. This article presents a framework for deploying a minimal number of smart meters to accurately track the ON of required smart meters is studied by an entropy-based approach, which qualifies the impact of meter

  6. 2007 Wholesale Power Rate Case Initial Proposal : Revenue Requirement Study.

    SciTech Connect (OSTI)

    United States. Bonneville Power Administration.

    2005-11-01T23:59:59.000Z

    The purpose of this Study is to establish the level of revenues from wholesale power rates necessary to recover, in accordance with sound business principles, the Federal Columbia River Power System (FCRPS) costs associated with the production, acquisition, marketing, and conservation of electric power. The generation revenue requirement includes: recovery of the Federal investment in hydro generation, fish and wildlife and conservation costs; Federal agencies' operations and maintenance (O&M) expenses allocated to power; capitalized contract expenses associated with non-Federal power suppliers such as Energy Northwest (EN); other power purchase expenses, such as short-term power purchases; power marketing expenses; cost of transmission services necessary for the sale and delivery of FCRPS power; and all other generation-related costs incurred by the Administrator pursuant to law.

  7. Methods for generating or increasing revenues from crops

    DOE Patents [OSTI]

    Copenhaver, Gregory P.; Keith, Kevin; Preuss, Daphne

    2007-03-20T23:59:59.000Z

    The present invention provides methods of doing business and providing services. For example, methods of increasing the revenue of crops are provided. To this end, the method includes the use of a nucleic acid sequences of plant centromeres. This will permit construction of stably inherited recombinant DNA constructs and mini chromosomes which can serve as vectors for the construction of transgenic plant and animal cells.

  8. Efficiency-Revenue Trade-offs in Auctions

    E-Print Network [OSTI]

    Diakonikolas, Ilias; Pierrakos, George; Singer, Yaron

    2012-01-01T23:59:59.000Z

    When agents with independent priors bid for a single item, Myerson's optimal auction maximizes expected revenue, whereas Vickrey's second-price auction optimizes social welfare. We address the natural question of trade-offs between the two criteria, that is, auctions that optimize, say, revenue under the constraint that the welfare is above a given level. If one allows for randomized mechanisms, it is easy to see that there are polynomial-time mechanisms that achieve any point in the trade-off (the Pareto curve) between revenue and welfare. We investigate whether one can achieve the same guarantees using deterministic mechanisms. We provide a negative answer to this question by showing that this is a (weakly) NP-hard problem. On the positive side, we provide polynomial-time deterministic mechanisms that approximate with arbitrary precision any point of the trade-off between these two fundamental objectives for the case of two bidders, even when the valuations are correlated arbitrarily. The major problem left...

  9. Liquid metal Flow Meter - Final Report

    SciTech Connect (OSTI)

    Andersen, C.; Hoogendoom, S.; Hudson, B.; Prince, J.; Teichert, K.; Wood, J.; Chase, K.

    2007-01-30T23:59:59.000Z

    Measuring the flow of liquid metal presents serious challenges. Current commercially-available flow meters use ultrasonic, electromagnetic, and other technologies to measure flow, but are inadequate for liquid metal flow measurement because of the high temperatures required by most liquid metals. As a result of the reactivity and high temperatures of most liquid metals, corrosion and leakage become very serious safety concerns. The purpose of this project is to develop a flow meter for Lockheed Martin that measures the flow rate of molten metal in a conduit.

  10. SOLVENT DISPERSION AND FLOW METER CALCULATION RESULTS

    SciTech Connect (OSTI)

    Nash, C.; Fondeur, F.; Peters, T.

    2013-06-21T23:59:59.000Z

    Savannah River National Laboratory (SRNL) found that the dispersion numbers for the six combinations of CSSX:Next Generation Solvent (NGS) “blend” and pure NGS versus salt solution, caustic wash, and strip aqueous solutions are all good. The dispersion numbers are indications of processability with centrifugal contactors. A comparison of solvent physical and thermal properties shows that the Intek™ solvent flow meter in the plant has a reading biased high versus calibrated flow when NGS is used, versus the standard CSSX solvent. The flow meter, calibrated for CSSX solvent, is predicted to read 2.8 gpm of NGS in a case where the true flow of NGS is 2.16 gpm.

  11. Enzyme replacement therapy for Pompe disease

    E-Print Network [OSTI]

    Burris, Ryan Jonathan William

    2010-01-01T23:59:59.000Z

    CALIFORNIA, SAN DIEGO Enzyme Replacement Therapy for Pompe3 1.3 Enzyme Replacement Therapy for Pompe Disease…………………… 5Receptor ERT – Enzyme Replacement Therapy LSD – Lysosomal

  12. Smart Meter Security Infrastructure: Some Observations

    E-Print Network [OSTI]

    Ladkin, Peter B.

    , access Smart Grid nodes via the Smart Meter, or pretend electricity use that is other than the actual use companies must prepare for large scale failure of Smart Grid nodes. There must be fallback strategies if there are no special precautions that isolate Smart Grid nodes from compromised nodes. To clean a compromised Smart

  13. Laser Power Meter Large, bright, backlit LCD

    E-Print Network [OSTI]

    Woodall, Jerry M.

    Laser Power Meter FEATURES · Large, bright, backlit LCD display · Digital accuracy with analog-like movement for laser tuning · Works with thermopile and optical sensors · Intuitive button-driven user COMPATIBILITY · PowerMax® thermal sensors · Optical sensors FieldMaxII-TO Coherent Laser Measurement and Control

  14. The economics of net metering Larry Hughes

    E-Print Network [OSTI]

    Hughes, Larry

    . In jurisdictions that permit net metering, the owners of these facilities (the customer-generators) can supply of financial compensation on the selection of generation equipment from the perspective of the customer that generate electricity intermittently (typically renewables such as wind and solar) need not be concerned

  15. Hardware Metering: A Survey Farinaz Koushanfar

    E-Print Network [OSTI]

    , the problem has recently gained an increased attention by the industry, government, and research community passive and active hardware metering methods available. Electrical and Computer Engineering Department only be performed in state-of-art fabrication facilities. Building or maintaining such facilities

  16. Energy Theft in the Advanced Metering Infrastructure

    E-Print Network [OSTI]

    McDaniel, Patrick Drew

    , with this infrastructure comes new risk. In this paper, we consider ad- versary means of defrauding the electrical gridEnergy Theft in the Advanced Metering Infrastructure Stephen McLaughlin, Dmitry Podkuiko, and Patrick McDaniel Systems and Internet Infrastructure Security Laboratory (SIIS) Pennsylvania State

  17. Smart Meter Company Boosting Production, Workforce

    Broader source: Energy.gov [DOE]

    A manufacturing facility in South Carolina is producing enough smart meters to reduce annual electricity use by approximately 1.7 million megawatt hours -- and through advanced manufacturing tax credits, just increased the facility's production capability by 20 percent and created 420 jobs.

  18. NATL Grid Map 50-Meter Grid

    E-Print Network [OSTI]

    Slatton, Clint

    NATL-east NATL Grid Map 50-Meter Grid Locations in NATL can be specified by reference to a grid intervals. Each gridline intersection ("grid point") is identified by its two gridlines (e.g., E5). Each 50x50-m block formed by the gridlines is identified by the grid point in its northwest corner (e

  19. 2011 W. Meyer Qualifizierungsbedarf Smart Metering

    E-Print Network [OSTI]

    Ulm, Universität

    1 2011 W. Meyer Qualifizierungsbedarf Smart Metering Qualifizierungsbedarf im Bereich Smart Netze und E - Mobility Willi Meyer Zentrum für Elektro- und Schulungsleiter Informationstechnik Nürnberg #12;2 2011 W. Meyer Alle Angaben wurden mit Sorgfalt und nach bestem Wissen und Gewissen erstellt. Es

  20. Window Replacement, Rehabilitation, & Repair Guides - Building...

    Energy Savers [EERE]

    Window Replacement, Rehabilitation, & Repair Guides - Building America Top Innovation Window Replacement, Rehabilitation, & Repair Guides - Building America Top Innovation Effec...

  1. Community Net Energy Metering: How Novel Policies Expand Benefits of Net Metering to Non-Generators

    SciTech Connect (OSTI)

    Rose, James; Varnado, Laurel

    2009-04-01T23:59:59.000Z

    As interest in community solutions to renewable energy grows, more states are beginning to develop policies that encourage properties with more than one meter to install shared renewable energy systems. State net metering policies are evolving to allow the aggregation of multiple meters on a customer���¢��������s property and to dissolve conventional geographical boundaries. This trend means net metering is expanding out of its traditional function as an enabling incentive to offset onsite customer load at a single facility. This paper analyzes community net energy metering (CNEM) as an emerging vehicle by which farmers, neighborhoods, and municipalities may more easily finance and reap the benefits of renewable energy. Specifically, it aims to compare and contrast the definition of geographical boundaries among different CNEM models and examine the benefits and limitations of each approach. As state policies begin to stretch the geographic boundaries of net metering, they allow inventive solutions to encourage renewable energy investment. This paper attempts to initiate the conversation on this emerging policy mechanism and offers recommendations for further development of these policies.

  2. Revenues From Employee Benefit Programs | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingofRetrofitting Doors on OpenRevenue From

  3. Revenues From Employee Benefit Programs | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMay 2015 <Department of ii iii ACKNOWLEDGEMENTS This studyRevenues From

  4. "2013 Non-Utility Power Producers- Revenue"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocksa. Appliances byA49. TotalRevenue" "(Data from form

  5. "2013 Total Electric Industry- Revenue (Thousands Dollars)"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocksa. Appliances byA49.Transportation" "(DataRevenue

  6. Fuel cell membrane hydration and fluid metering

    DOE Patents [OSTI]

    Jones, Daniel O. (Glenville, NY); Walsh, Michael M. (Fairfield, CT)

    2003-01-01T23:59:59.000Z

    A hydration system includes fuel cell fluid flow plate(s) and injection port(s). Each plate has flow channel(s) with respective inlet(s) for receiving respective portion(s) of a given stream of reactant fluid for a fuel cell. Each injection port injects a portion of liquid water directly into its respective flow channel. This serves to hydrate at least corresponding part(s) of a given membrane of the corresponding fuel cell(s). The hydration system may be augmented by a metering system including flow regulator(s). Each flow regulator meters an injecting at inlet(s) of each plate of respective portions of liquid into respective portion(s) of a given stream of fluid by corresponding injection port(s).

  7. Fuel cell membrane hydration and fluid metering

    DOE Patents [OSTI]

    Jones, Daniel O. (Glenville, NY); Walsh, Michael M. (Fairfield, CT)

    1999-01-01T23:59:59.000Z

    A hydration system includes fuel cell fluid flow plate(s) and injection port(s). Each plate has flow channel(s) with respective inlet(s) for receiving respective portion(s) of a given stream of reactant fluid for a fuel cell. Each injection port injects a portion of liquid water directly into its respective flow channel in order to mix its respective portion of liquid water with the corresponding portion of the stream. This serves to hydrate at least corresponding part(s) of a given membrane of the corresponding fuel cell(s). The hydration system may be augmented by a metering system including flow regulator(s). Each flow regulator meters an injecting at inlet(s) of each plate of respective portions of liquid into respective portion(s) of a given stream of fluid by corresponding injection port(s).

  8. The Need for Essential Consumer Protections: Smart metering proposals...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    metering proposals and the move to time-based pricing. August 2010 The Need for Essential Consumer Protections: Smart metering proposals and the move to time-based pricing. August...

  9. Wireless Electricity Metering of Miscellaneous and Electronic Devices in Buildings

    E-Print Network [OSTI]

    Culler, David E.

    Wireless Electricity Metering of Miscellaneous and Electronic Devices in Buildings, University of California, Berkeley, USA Abstract- Miscellaneous and electronic devices hundreds of miscellaneous and electronic devices where metered for several months

  10. Exploring Opportunities for Energy Efficiency as a Revenue Stream in the Forward Capacity Markets

    Broader source: Energy.gov [DOE]

    Provides information for energy efficiency programs on the opportunities and challenges associated with participating in forward capacity markets and reliability pricing models as potential revenue streams.

  11. Alaska Electric Light&Power Co (Alaska) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 27165 Total Consumers 15955 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  12. Alaska Electric Light&Power Co (Alaska) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 18050 Total Consumers 15886 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  13. Alaska Electric Light&Power Co (Alaska) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 30637 Total Consumers 15914 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  14. Alaska Electric Light&Power Co (Alaska) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 23039 Total Consumers 15910 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  15. Alaska Electric Light&Power Co (Alaska) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 19019 Total Consumers 15891 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  16. Alaska Electric Light&Power Co (Alaska) EIA Revenue and Sales...

    Open Energy Info (EERE)

    (MWh) 27724.952 Total Consumers 15949 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  17. Alaska Electric Light&Power Co (Alaska) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 26729 Total Consumers 15898 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  18. Alaska Electric Light&Power Co (Alaska) EIA Revenue and Sales...

    Open Energy Info (EERE)

    (MWh) 27020.525 Total Consumers 15945 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  19. Alaska Electric Light&Power Co (Alaska) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 28400 Total Consumers 15946 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  20. Alaska Electric Light&Power Co (Alaska) EIA Revenue and Sales...

    Open Energy Info (EERE)

    Sales (MWh) 28597 Total Consumers 15902 Source: Energy Information Administration. Form EIA-826 Database Monthly Electric Utility Sales and Revenue Data 1 Previous | Next...

  1. Lender-Based Revenues and Cost-Savings | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Program Sustainability Peer Exchange Call: Lender-Based Revenues and Cost-Savings, Call Slides and Summary, February 14, 2013. Call Slides and Summary More Documents & Publications...

  2. Author's personal copy Ramp metering and freeway bottleneck capacity

    E-Print Network [OSTI]

    Levinson, David M.

    ; Hall and Agyemang-Duah, 1991; Banks, 1991a,b). The two-capacity hypothesis argues that metering can

  3. Energy Secretary Chu Announces Five Million Smart Meters Installed...

    Office of Environmental Management (EM)

    metering infrastructure (AMI), distribution automation technologies, new electricity pricing programs, and advanced monitoring equipment for the transmission system. The goal...

  4. Optimal Privacy-Preserving Energy Management for Smart Meters

    E-Print Network [OSTI]

    Reisslein, Martin

    Optimal Privacy-Preserving Energy Management for Smart Meters Lei Yang, Xu Chen, Junshan Zhang Abstract--Smart meters, designed for information collection and system monitoring in smart grid, report a tradeoff between the smart meter data privacy and the electricity bill. In general, a major challenge

  5. Security and Smart Metering Sophia Kaplantzis and Y. Ahmet Sekercioglu

    E-Print Network [OSTI]

    Sekercioglu, Y. Ahmet

    Security and Smart Metering Sophia Kaplantzis and Y. Ahmet S¸ekercioglu Department of Electrical the transmission network, to the suppliers back office. It encompasses concepts such as smart metering, smart does this threat translate to smart metering applications? In this article, we focus on the security

  6. Privacy Preserving Smart Metering System Based Retail Level Electricity Market

    E-Print Network [OSTI]

    Franchetti, Franz

    1 Privacy Preserving Smart Metering System Based Retail Level Electricity Market Cory Thoma, Tao Cui, Student Member, IEEE, Franz Franchetti, Member, IEEE Abstract--Smart metering systems multi-party compu- tation (SMC) based privacy preserving smart metering system. Using the proposed SMC

  7. Secure Multiparty Computation Based Privacy Preserving Smart Metering System

    E-Print Network [OSTI]

    Franchetti, Franz

    Secure Multiparty Computation Based Privacy Preserving Smart Metering System Cory Thoma Information Ave. Pittsburgh, PA 15213 Email: {tcui,franzf}@ece.cmu.edu Abstract--Smart metering systems provide privacy preserving protocol for smart meter based load management. Using SMC and a proper designed

  8. Smart Meter Aware Domestic Energy Trading Agents Nicola Capodieci

    E-Print Network [OSTI]

    Aiello, Marco

    Smart Meter Aware Domestic Energy Trading Agents Nicola Capodieci University of Modena and RE illustrate an implementation includ- ing the interfacing with a physical Smart Meter and provide initial--Intelligent agents, Multiagent systems General Terms Design, Economy Keywords Energy trade, agents, smart meter 1

  9. Leveraging smart meter data to recognize home appliances Markus Weiss+#

    E-Print Network [OSTI]

    Leveraging smart meter data to recognize home appliances Markus Weiss+# , Adrian Helfenstein -- The worldwide adoption of smart meters that measure and communicate residential electricity consumption gives demand. In this paper we present an infrastructure and a set of algorithms that make use of smart meters

  10. Security Architecture of Smart Metering Systems Natasa Zivic1

    E-Print Network [OSTI]

    Boyer, Edmond

    Security Architecture of Smart Metering Systems Natasa Zivic1 and Christoph Ruland1 1 University.Zivic, Christoph.Ruland}@uni-siegen.de Abstract. The main goals of smart metering are the reduction of costs dynamically the power generation and distribution to the requested energy by smart grids. Metering devices

  11. Smart-Metering for Monitoring Building Power Distribution Network using Instantaneous Phasor Computations of Electrical Signals

    E-Print Network [OSTI]

    K.R., Krishnanand

    2013-01-01T23:59:59.000Z

    efficient operation of a smart meter network . in IndustrialGood standards for smart meters . in European EnergyHardware development for Smart Meter based innovations . in

  12. Virent is Replacing Crude Oil

    Broader source: Energy.gov [DOE]

    Breakout Session 2A—Conversion Technologies II: Bio-Oils, Sugar Intermediates, Precursors, Distributed Models, and Refinery Co-Processing Virent is Replacing Crude Oil Randy Cortright, Founder & Chief Technology Officer, Virent

  13. Buying Vs. Raising Replacement Heifers

    E-Print Network [OSTI]

    Cleere, Jason

    2006-01-02T23:59:59.000Z

    When deciding on the best strategy for replacing heifers, beef cattle producers should weigh several factors. This publication discusses several such issues, including current and future market prices; herd size; pastures, facilities and management...

  14. NUCLEAR MIXING METERS FOR CLASSICAL NOVAE

    SciTech Connect (OSTI)

    Kelly, Keegan J.; Iliadis, Christian; Downen, Lori; Champagne, Art [Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3255 (United States); José, Jordi [Departament de Física i Enginyeria Nuclear, EUETIB, Universitat Politècnica de Catalunya, E-08036 Barcelona (Spain)

    2013-11-10T23:59:59.000Z

    Classical novae are caused by mass transfer episodes from a main-sequence star onto a white dwarf via Roche lobe overflow. This material possesses angular momentum and forms an accretion disk around the white dwarf. Ultimately, a fraction of this material spirals in and piles up on the white dwarf surface under electron-degenerate conditions. The subsequently occurring thermonuclear runaway reaches hundreds of megakelvin and explosively ejects matter into the interstellar medium. The exact peak temperature strongly depends on the underlying white dwarf mass, the accreted mass and metallicity, and the initial white dwarf luminosity. Observations of elemental abundance enrichments in these classical nova events imply that the ejected matter consists not only of processed solar material from the main-sequence partner but also of material from the outer layers of the underlying white dwarf. This indicates that white dwarf and accreted matter mix prior to the thermonuclear runaway. The processes by which this mixing occurs require further investigation to be understood. In this work, we analyze elemental abundances ejected from hydrodynamic nova models in search of elemental abundance ratios that are useful indicators of the total amount of mixing. We identify the abundance ratios ?CNO/H, Ne/H, Mg/H, Al/H, and Si/H as useful mixing meters in ONe novae. The impact of thermonuclear reaction rate uncertainties on the mixing meters is investigated using Monte Carlo post-processing network calculations with temperature-density evolutions of all mass zones computed by the hydrodynamic models. We find that the current uncertainties in the {sup 30}P(p, ?){sup 31}S rate influence the Si/H abundance ratio, but overall the mixing meters found here are robust against nuclear physics uncertainties. A comparison of our results with observations of ONe novae provides strong constraints for classical nova models.

  15. Widget:GoalMeter | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to:Ezfeedflag JumpID-fTri GlobalJump to:WestwoodCreatePageFormFieldsDisplayToggleGoalMeter Jump

  16. 2010 Smart Meter Installations | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently20,000 Russian NuclearandJune 17, 2015 SEABOnlyTipsWorkingErichsecurity10 Smart Meter

  17. greenMeter | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells, Wisconsin: EnergyWyandanch,Eaga SolarZoloHome Dc'scloudgridgreenMeter

  18. Power Metering Project | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMay 2015 < prev next > Sun Mon Tue Wed May 28-29,Metering Project Power

  19. Carbon Tax Revenue and the Budget Deficit: A Win-Win-Win Solution?

    E-Print Network [OSTI]

    Rausch, Sebastian

    Bush-era tax cuts are scheduled to expire at the end of 2012, leading to interest in raising revenue through a carbon tax. This revenue could be used to either cut other taxes or to avoid cuts in Federal programs. There ...

  20. Assessment of net lost revenue adjustment mechanisms for utility DSM programs

    SciTech Connect (OSTI)

    Baxter, L.W.

    1995-01-01T23:59:59.000Z

    Utility shareholders can lose money on demand-side management (DSM) investments between rate cases. Several industry analysts argue that the revenues lost from utility DSM programs are an important financial disincentive to utility DSM investment. A key utility regulatory reform undertaken since 1989 allows utilities to recover the lost revenues incurred through successful operation of DSM programs. Explicitly defined net lost revenue adjustment (NLRA) mechanisms are states` preferred approach to lost revenue recovery from DSM programs. This report examines the experiences states and utilities are having with the NLRA approach. The report has three objectives. First, we determine whether NLRA is a feasible and successful approach to removing the lost-revenue disincentive to utility operation of DSM programs. Second, we identify the conditions linked to successful implementation of NLRA mechanisms in different states and assess whether NLRA has changed utility investment behavior. Third, we suggest improvements to NLRA mechanisms. We first identify states with NLRA mechanisms where utilities are recovering lost revenues from DSM programs. We interview staff at regulatory agencies in all these states and utility staff in four states. These interviews focus on the status of NLRA, implementation issues, DSM measurement issues, and NLRA results. We also analyze regulatory agency orders on NLRA, as well as associated testimony, reports, and utility lost revenue recovery filings. Finally, we use qualitative and quantitative indicators to assess NLRA`s effectiveness. Contrary to the concerns raised by some industry analysts, our results indicate NLRA is a feasible approach to the lost-revenue disincentive.

  1. A Synthesis of Cost and Revenue Surveys for Gulf of Mexico Shrimp Vessels

    E-Print Network [OSTI]

    series cost data are not routinely collected for vessels operat ing in any of the U.S. southeast region of Published Cost and Revenue Data Differences underlying the cost and revenue surveys prevent direct compari in the survey data. For example, changes in the cost an

  2. Federal offshore statistics: 1995 - leasing, exploration, production, and revenue as of December 31, 1995

    SciTech Connect (OSTI)

    Gaechter, R.A.

    1997-07-01T23:59:59.000Z

    This report provides data on federal offshore operations for 1995. Information is included for leasing activities, development, petroleum and natural gas production, sales and royalties, revenue from federal offshore leasing, disbursement of federal revenues, reserves and resource estimates, and oil pollution in U.S. and international waters.

  3. Pricing under Constraints in Access Networks: Revenue Maximization and Congestion Management

    E-Print Network [OSTI]

    Reisslein, Martin

    such "technical" practices and promotes economics based approaches. We characterize the loss in ISP revenue from Prashanth Hande1,2, Mung Chiang1, Robert Calderbank1, Junshan Zhang3 1 Department of Electrical Engineering consumers, and we derive the revenue loss to the ISP from such restrictions. We then develop partial

  4. Maximizing Cloud Providers Revenues via Energy Aware Allocation Policies

    E-Print Network [OSTI]

    Mazzucco, Michele; Deters, Ralph

    2011-01-01T23:59:59.000Z

    Cloud providers, like Amazon, offer their data centers' computational and storage capacities for lease to paying customers. High electricity consumption, associated with running a data center, not only reflects on its carbon footprint, but also increases the costs of running the data center itself. This paper addresses the problem of maximizing the revenues of Cloud providers by trimming down their electricity costs. As a solution allocation policies which are based on the dynamic powering servers on and off are introduced and evaluated. The policies aim at satisfying the conflicting goals of maximizing the users' experience while minimizing the amount of consumed electricity. The results of numerical experiments and simulations are described, showing that the proposed scheme performs well under different traffic conditions.

  5. Anytime Replanning Using Local Subplan Replacement

    E-Print Network [OSTI]

    Ferrer, Gabriel J.

    Anytime Replanning Using Local Subplan Replacement A Dissertation Presented to the faculty how local subplan replacement can be utilized to implement an anytime planning system that devises new plans to accommodate plan failures. Local subplan replacement consists of selecting subsequences

  6. Long Island Smart Metering Pilot Project

    SciTech Connect (OSTI)

    None

    2012-03-30T23:59:59.000Z

    The Long Island Power Authority (LIPA) Smart Meter Pilots provided invaluable information and experience for future deployments of Advanced Metering Infrastructure (AMI), including the deployment planned as part of LIPAâ??s Smart Grid Demonstration Project (DE-OE0000220). LIPA will incorporate lessons learned from this pilot in future deployments, including lessons relating to equipment performance specifications and testing, as well as equipment deployment and tracking issues. LIPA ultimately deployed three AMI technologies instead of the two that were originally contemplated. This enabled LIPA to evaluate multiple systems in field conditions with a relatively small number of meter installations. LIPA experienced a number of equipment and software issues that it did not anticipate, including issues relating to equipment integration, ability to upgrade firmware and software â??over the airâ? (as opposed to physically interacting with every meter), and logistical challenges associated with tracking inventory and upgrade status of deployed meters. In addition to evaluating the technology, LIPA also piloted new Time-of-Use (TOU) rates to assess customer acceptance of time-differentiated pricing and to evaluate whether customers would respond by adjusting their activities from peak to non-peak periods. LIPA developed a marketing program to educate customers who received AMI in the pilot areas and to seek voluntary participation in TOU pricing. LIPA also guaranteed participating customers that, for their initial year on the rates, their electricity costs under the TOU rate would not exceed the amount they would have paid under the flat rates they would otherwise enjoy. 62 residential customers chose to participate in the TOU rates, and every one of them saved money during the first year. 61 of them also elected to stay on the TOU rate â?? without the cost guarantee â?? at the end of that year. The customer who chose not to continue on the rate was also the one who achieved the greatest savings. However, after the first year, the customer in question installed equipment that would have made TOU rates a more costly option than the residential flat rate. During the second year, all but one customer saved money. That customer increased usage during peak hours, and as a result saw an increase in annual costs (as compared to the flat rate) of $24.17. The results were less clear for commercial customers, which LIPA attributes to rate design issues that it will take into account for future deployments. LIPA views this pilot as a complete success. Not only is LIPA better prepared for a larger deployment of AMI, but it is confident that residential customers will accept AMI and TOU rates and shift their energy consumption from peak to non-peak periods in response to pricing. On a larger scale, this will benefit LIPA and all of its customers by potentially lowering peak demand when energy costs are highest.

  7. Do You Have Windows That Need Replacing?

    Broader source: Energy.gov [DOE]

    Do you have windows that need replacing, too? Do you have any plans to replace them with newer, more efficient windows?

  8. Method and apparatus for reading meters from a video image

    DOE Patents [OSTI]

    Lewis, Trevor J. (Irwin, PA); Ferguson, Jeffrey J. (North Huntingdon, PA)

    1997-01-01T23:59:59.000Z

    A method and system to enable acquisition of data about an environment from one or more meters using video images. One or more meters are imaged by a video camera and the video signal is digitized. Then, each region of the digital image which corresponds to the indicator of the meter is calibrated and the video signal is analyzed to determine the value indicated by each meter indicator. Finally, from the value indicated by each meter indicator in the calibrated region, a meter reading is generated. The method and system offer the advantages of automatic data collection in a relatively non-intrusive manner without making any complicated or expensive electronic connections, and without requiring intensive manpower.

  9. Thirty Meter Telescope Detailed Science Case: 2015

    E-Print Network [OSTI]

    Skidmore, Warren; Fukugawa, Misato; Goswami, Aruna; Hao, Lei; Jewitt, David; Laughlin, Greg; Steidel, Charles; Hickson, Paul; Simard, Luc; Schöck, Matthias; Treu, Tommaso; Cohen, Judith; Anupama, G C; Dickinson, Mark; Harrison, Fiona; Kodama, Tadayuki; Lu, Jessica R; Macintosh, Bruce; Malkan, Matt; Mao, Shude; Narita, Norio; Sekiguchi, Tomohiko; Subramaniam, Annapurni; Tanaka, Masaomi; Tian, Feng; A'Hearn, Michael; Akiyama, Masayuki; Ali, Babar; Aoki, Wako; Bagchi, Manjari; Barth, Aaron; Bhalerao, Varun; Bradac, Marusa; Bullock, James; Burgasser, Adam J; Chapman, Scott; Chary, Ranga-Ram; Chiba, Masashi; Cooray, Asantha; Crossfield, Ian; Currie, Thayne; Das, Mousumi; Dewangan, G C; de Grijs, Richard; Do, Tuan; Dong, Subo; Evslin, Jarah; Fang, Taotao; Fang, Xuan; Fassnacht, Christopher; Fletcher, Leigh; Gaidos, Eric; Gal, Roy; Ghez, Andrea; Giavalisco, Mauro; Grady, Carol A; Greathouse, Thomas; Gogoi, Rupjyoti; Guhathakurta, Puragra; Ho, Luis; Hasan, Priya; Herczeg, Gregory J; Honda, Mitsuhiko; Imanishi, Masa; Inanmi, Hanae; Iye, Masanori; Kamath, U S; Kane, Stephen; Kashikawa, Nobunari; Kasliwal, Mansi; Kirby, Vishal KasliwalEvan; Konopacky, Quinn M; Lepine, Sebastien; Li, Di; Li, Jianyang; Liu, Junjun; Liu, Michael C; Lopez-Rodriguez, Enrigue; Lotz, Jennifer; Lubin, Philip; Macri, Lucas; Maeda, Keiichi; Marchis, Franck; Marois, Christian; Marscher, Alan; Martin, Crystal; Matsuo, Taro; Max, Claire; McConnachie, Alan; McGough, Stacy; Melis, Carl; Meyer, Leo; Mumma, Michael; Muto, Takayuki; Nagao, Tohru; Najita, Joan R; Navarro, Julio; Pierce, Michael; Prochaska, Jason X; Oguri, Masamune; Ojha, Devendra K; Okamoto, Yoshiko K; Orton, Glenn; Otarola, Angel; Ouchi, Masami; Packham, Chris; Padgett, Deborah L; Pandey, Shashi Bhushan; Pilachowsky, Catherine; Pontoppidan, Klaus M; Primack, Joel; Puthiyaveettil, Shalima; Ramirez-Ruiz, Enrico; Reddy, Naveen; Rich, Michael; Richter, Matthew J; Schombert, James; Sen, Anjan Ananda; Shi, Jianrong; Sheth, Kartik; Srianand, R; Tan, Jonathan C; Tanaka, Masayuki; Tanner, Angelle; Tominaga, Nozomu; Tytler, David; U, Vivian; Wang, Lingzhi; Wang, Xiaofeng; Wang, Yiping; Wilson, Gillian; Wright, Shelley; Wu, Chao; Wu, Xufeng; Xu, Renxin; Yamada, Toru; Yang, Bin; Zhao, Gongbo; Zhao, Hongsheng

    2015-01-01T23:59:59.000Z

    The TMT Detailed Science Case describes the transformational science that the Thirty Meter Telescope will enable. Planned to begin science operations in 2024, TMT will open up opportunities for revolutionary discoveries in essentially every field of astronomy, astrophysics and cosmology, seeing much fainter objects much more clearly than existing telescopes. Per this capability, TMT's science agenda fills all of space and time, from nearby comets and asteroids, to exoplanets, to the most distant galaxies, and all the way back to the very first sources of light in the Universe. More than 150 astronomers from within the TMT partnership and beyond offered input in compiling the new 2015 Detailed Science Case. The contributing astronomers represent the entire TMT partnership, including the California Institute of Technology (Caltech), the Indian Institute of Astrophysics (IIA), the National Astronomical Observatories of the Chinese Academy of Sciences (NAOC), the National Astronomical Observatory of Japan (NAOJ),...

  10. Smart Metering and Electricity Demand: Technology, Economics and International Experience

    E-Print Network [OSTI]

    Brophy Haney, A; Jamasb, Tooraj; Pollitt, Michael G.

    www.eprg.group.cam.ac.uk E P R G W O R K IN G P A P E R Abstract Smart Metering and Electricity Demand: Technology, Economics and International Experience EPRG Working Paper EPRG0903 Cambridge Working Paper in Economics 0905 Aoife... Brophy Haney, Tooraj Jamasb and Michael G. Pollitt In recent years smart metering of electricity demand has attracted attention around the world. A number of countries and regions have started deploying new metering systems; and many others have...

  11. Optimization Online - A Security Framework for Smart Metering with ...

    E-Print Network [OSTI]

    Cristina Rottondi

    2011-12-05T23:59:59.000Z

    Dec 5, 2011 ... Abstract: The increasing diffusion of Automatic Meter Reading (AMR) has raised many concerns about the protection of personal data related to ...

  12. Hydro-Québec Net Metering (Quebec, Canada) | Open Energy Information

    Open Energy Info (EERE)

    Canada) Policy Type Net Metering Affected Technologies Geothermal Electric, Solar Photovoltaics Active Policy Yes Implementing Sector Utility Funding Source Hydro-Quebec Primary...

  13. The Intersection of Net Metering and Retail Choice: An Overview...

    Energy Savers [EERE]

    and utilities provide net metering options for their customers. They then provided case studies to illustrate the models. Date December 2010 Topic Financing, Incentives &...

  14. Wavelength meter having single mode fiber optics multiplexed inputs

    DOE Patents [OSTI]

    Hackel, Richard P. (Livermore, CA); Paris, Robert D. (San Ramon, CA); Feldman, Mark (Pleasanton, CA)

    1993-01-01T23:59:59.000Z

    A wavelength meter having a single mode fiber optics input is disclosed. The single mode fiber enables a plurality of laser beams to be multiplexed to form a multiplexed input to the wavelength meter. The wavelength meter can provide a determination of the wavelength of any one or all of the plurality of laser beams by suitable processing. Another aspect of the present invention is that one of the laser beams could be a known reference laser having a predetermined wavelength. Hence, the improved wavelength meter can provide an on-line calibration capability with the reference laser input as one of the plurality of laser beams.

  15. Two-Meter Temperature Surveys for Geothermal Exploration Project...

    Open Energy Info (EERE)

    being considered in this project. Initial results from two-meter temperature surveys on Navy managed land near Fallon, Nevada indicate the presence of several temperature...

  16. Wavelength meter having single mode fiber optics multiplexed inputs

    DOE Patents [OSTI]

    Hackel, R.P.; Paris, R.D.; Feldman, M.

    1993-02-23T23:59:59.000Z

    A wavelength meter having a single mode fiber optics input is disclosed. The single mode fiber enables a plurality of laser beams to be multiplexed to form a multiplexed input to the wavelength meter. The wavelength meter can provide a determination of the wavelength of any one or all of the plurality of laser beams by suitable processing. Another aspect of the present invention is that one of the laser beams could be a known reference laser having a predetermined wavelength. Hence, the improved wavelength meter can provide an on-line calibration capability with the reference laser input as one of the plurality of laser beams.

  17. Scotia Energy Electricity- Net Metering Program (Nova Scotia, Canada)

    Broader source: Energy.gov [DOE]

    Nova Scotia Power Inc. Net Metering allows residential and commercial customers to connect small, renewable energy generating units to the provincial power grid.

  18. Maritime Electric- Net Metering (Prince Edward Island, Canada)

    Broader source: Energy.gov [DOE]

    In December 2005 The Renewable Energy Act and associated Regulations came into effect. A Government policy objective incorporated in the Act was the introduction of net metering for...

  19. Cost benefit analysis for the implementation of smart metering...

    Open Energy Info (EERE)

    Smart Grid Projects Smart Grid Projects in Europe Smart Grid Projects - Smart Meter and AMI Smart Grid Projects - Home application Smart Grid Projects - Customer Behavior...

  20. REPLACEMENT DIPLOMA REQUEST FORM Dear Alumni

    E-Print Network [OSTI]

    Dennett, Daniel

    REPLACEMENT DIPLOMA REQUEST FORM Dear Alumni: It is our understanding that you need to replace your original diploma. We are glad to help you attain a replacement diploma. The items listed below are required replacement diploma. Please feel free to contact the LGBT Center at 617-627-3770 if you have questions

  1. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    E-Print Network [OSTI]

    Darghouth, Naim Richard

    2013-01-01T23:59:59.000Z

    Study: The Economic Cost of Net-Metering in Maryland: WhoEnergy (DSIRE), 2010. Map of Net Metering Policies [WWWdocuments/summarymaps/Net_Metering_map.ppt De Jonghe, C. ,

  2. Shallow (2-meter) temperature surveys in Colorado

    SciTech Connect (OSTI)

    Zehner, Richard E.

    2012-02-01T23:59:59.000Z

    Citation Information: Originator: Geothermal Development Associates, Reno, Nevada Publication Date: 2012 Title: Colorado 2m Survey Edition: First Publication Information: Publication Place: Reno Nevada Publisher: Geothermal Development Associates, Reno, Nevada Description: Shallow temperature surveys are useful in early-stage geothermal exploration to delineate surface outflow zones, with the intent to identify the source of upwelling, usually a fault. Detailed descriptions of the 2-meter survey method and equipment design can be found in Coolbaugh et al. (2007) and Sladek et al. (2007), and are summarized here. The survey method was devised to measure temperature as far below the zone of solar influence as possible, have minimal equilibration time, and yet be portable enough to fit on the back of an all-terrain vehicle (ATV); Figure 2). This method utilizes a direct push technology (DPT) technique where 2.3 m long, 0.54” outer diameter hollow steel rods are pounded into the ground using a demolition hammer. Resistance temperature devices (RTD) are then inserted into the rods at 2-meter depths, and allowed to equilibrate for one hour. The temperatures are then measured and recorded, the rods pulled out of the ground, and re-used at future sites. Usually multiple rods are planted over the course of an hour, and then the sampler returns back to the first station, measures the temperatures, pulls the rods, and so on, to eliminate waiting time. At Wagon Wheel Gap, 32 rods were planted around the hot springs between June 20 and July 1, 2012. The purpose was to determine the direction of a possible upflow fault or other structure. Temperatures at 1.5m and 2m depths were measured and recorded in the attribute table of this point shapefile. Several anomalous temperatures suggest that outflow is coming from a ~N60W striking fault or shear zone that contains the quartz-fluorite-barite veins of the adjacent patented mining claims. It should be noted that temperatures at 2m depth vary according to the amount of solar heating from above, as well as possible geothermal heating from below. Spatial Domain: Extent: Top: 4490310.560635 m Left: 150307.008238 m Right: 433163.213617 m Bottom: 4009565.915398 m Contact Information: Contact Organization: Geothermal Development Associates, Reno, Nevada Contact Person: Richard “Rick” Zehner Address: 3740 Barron Way City: Reno State: NV Postal Code: 89511 Country: USA Contact Telephone: 775-737-7806 Spatial Reference Information: Coordinate System: Universal Transverse Mercator (UTM) WGS’1984 Zone 13N False Easting: 500000.00000000 False Northing: 0.00000000 Central Meridian: -105.00000000 Scale Factor: 0.99960000 Latitude of Origin: 0.00000000 Linear Unit: Meter Datum: World Geodetic System 1984 (WGS ’1984) Prime Meridian: Greenwich Angular Unit: Degree Digital Form: Format Name: Shape file

  3. Modelling the performance of revenue management systems in different competitive environments

    E-Print Network [OSTI]

    Dar, Maital

    2006-01-01T23:59:59.000Z

    In the wake of contemporary widespread fare simplification in many major airline markets, this thesis is concerned with the possibilities and the potential for airline revenue management in less-differentiated fare ...

  4. The value of revenue management innovation in a competitive airline industry

    E-Print Network [OSTI]

    Wilson, John L.

    1995-01-01T23:59:59.000Z

    The value of revenue management to the airlines has been amply demonstrated, both by industry experience and in simulation studies of the reservation process. However, there have been no attempts to determine if the benefits ...

  5. Naval petroleum reserves: Preliminary analysis of future net revenues from Elk Hills production

    SciTech Connect (OSTI)

    Not Available

    1986-01-01T23:59:59.000Z

    This is an interim report on the present value of the net revenues from Elk Hills Naval Petroleum Reserve. GAO calculated alternative present values of the net revenues applying (1) low, medium, and high forecasts of future crude oil prices and (2) alternative interest rates for discounting the future net revenues to their present values. The calculations are sensitive to both the oil price forecasts and discount rates used; they are preliminary and should be used with caution. They do not take into account possible added tax revenues collected by the government if Elk Hills were sold nor varying production levels and practices, which could either increase or decrease the total amount of oil that can be extracted.

  6. Tradeoffs between revenue enhancements and emissions reductions with energy storage-coupled photovoltaics

    E-Print Network [OSTI]

    Heidel, Timothy David

    2009-01-01T23:59:59.000Z

    Energy storage has the potential to dramatically change the operation of photovoltaics by allowing for a delay between generation and use. This flexibility has the potential to impact both the revenue from generating ...

  7. A Global Personal Energy Meter University of Cambridge Computer Laboratory

    E-Print Network [OSTI]

    Cambridge, University of

    - sumption figures scaled by a predetermined factor for the type of energy used and divided equally amongstA Global Personal Energy Meter Simon Hay University of Cambridge Computer Laboratory Abstract of goods and provision of services. I envisage a personal energy meter which can record and apportion

  8. The impact of federal revenue sharing on recreation and parks in Texas

    E-Print Network [OSTI]

    Verinder, Sydney Henry

    1974-01-01T23:59:59.000Z

    to return power to the people and strengthen the state and local partners in our federal system. . ~ . a New Fed- eralism. " (Department of the Treasury, 1974a: 1) Revenue Sharing goes a step beyond block grants in giving states and localities autonomy... December 1974 Major Subject& Recreation and Resources Development THE Il&PACT OF FEDERAL REVENUE SHARING ON RECREATION AND PARKS IN TEXAS A Thesis by SYDNEY HENRY VERINDER Approved as to style and content by: ai . an of' Committee . ead...

  9. Federal Offshore Statistics, 1993. Leasing, exploration, production, and revenue as of December 31, 1993

    SciTech Connect (OSTI)

    Francois, D.K.

    1994-12-31T23:59:59.000Z

    This document contains statistical data on the following: federal offshore lands; offshore leasing activity and status; offshore development activity; offshore production of crude oil and natural gas; federal offshore oil and natural gas sales volume and royalties; revenue from federal offshore leases; disbursement of federal offshore revenue; reserves and resource estimates of offshore oil and natural gas; oil pollution in US and international waters; and international activities and marine minerals. A glossary is included.

  10. Solid state watt-hour meter

    SciTech Connect (OSTI)

    Hurley, J.R.; Gilker, C.S.

    1984-08-21T23:59:59.000Z

    A watt-hour meter is disclosed which includes: a microprocessor coupled to a solid-state Hall-Effect sensor; an electrically alterable ROM coupled to the microprocessor; a power supply; a power outage timing means using the discharge characteristic of a capacitor; apparatus for supplying a 60 Hz clock signal to the microprocessor; a readout device coupled to the microprocessor to provide an indication of the power consumed; an output on the microprocessor for controlling a circuit breaker; and a switch for overriding the microprocessor controlled circuit breaker. The microprocessor and the electrically alterable ROM are connected and programmed: to sense the time of day as determined from an initial time of day and setting the 60 Hz clock signal; to sense and compute the power used by the consumer; to automatically open the circuit breaker when power demand on the electric power source is high and/or the cost per kilowatt hour is high; to automatically close the circuit breaker when the power demand on the source of electric power is low and/or the cost per kilowatt power is low; and to allow a consumer to override the microprocessor's control of the circuit breaker.

  11. Embedded Firmware Diversity for Smart Electric Meters Stephen McLaughlin, Dmitry Podkuiko, Adam Delozier

    E-Print Network [OSTI]

    McDaniel, Patrick Drew

    Embedded Firmware Diversity for Smart Electric Meters Stephen McLaughlin, Dmitry Podkuiko, Adam}@cse.psu.edu Abstract Smart meters are now being aggressively deployed world- wide, with tens of millions of meters- niques can limit large-scale attacks on smart meters. We show how current meter designs do not possess

  12. Financial sustainability in municipal solid waste management – Costs and revenues in Bahir Dar, Ethiopia

    SciTech Connect (OSTI)

    Lohri, Christian Riuji, E-mail: christian.lohri@eawag.ch; Camenzind, Ephraim Joseph, E-mail: ephraimcamenzind@hotmail.com; Zurbrügg, Christian, E-mail: christian.zurbruegg@eawag.ch

    2014-02-15T23:59:59.000Z

    Highlights: • Cost-revenue analysis over 2 years revealed insufficient cost-recovery. • Expenses for motorized secondary collection increased by 82% over two years. • Low fee collection rate and reliance on only one revenue stream are problematic. • Different options for cost reduction and enhanced revenue streams are recommended. • Good public–private alliance is crucial to plan and implement improvement measures. - Abstract: Providing good solid waste management (SWM) services while also ensuring financial sustainability of the system continues to be a major challenge in cities of developing countries. Bahir Dar in northwestern Ethiopia outsourced municipal waste services to a private waste company in 2008. While this institutional change has led to substantial improvement in the cleanliness of the city, its financial sustainability remains unclear. Is the private company able to generate sufficient revenues from their activities to offset the costs and generate some profit? This paper presents a cost-revenue analysis, based on data from July 2009 to June 2011. The analysis reveals that overall costs in Bahir Dar’s SWM system increased significantly during this period, mainly due to rising costs related to waste transportation. On the other hand, there is only one major revenue stream in place: the waste collection fee from households, commercial enterprises and institutions. As the efficiency of fee collection from households is only around 50%, the total amount of revenues are not sufficient to cover the running costs. This results in a substantial yearly deficit. The results of the research therefore show that a more detailed cost structure and cost-revenue analysis of this waste management service is important with appropriate measures, either by the privates sector itself or with the support of the local authorities, in order to enhance cost efficiency and balance the cost-revenues towards cost recovery. Delays in mitigating the evident financial deficit could else endanger the public-private partnership (PPP) and lead to failure of this setup in the medium to long term, thus also endangering the now existing improved and currently reliable service. We present four options on how financial sustainability of the SWM system in Bahir Dar might be enhanced: (i) improved fee collection efficiency by linking the fees of solid waste collection to water supply; (ii) increasing the value chain by sales of organic waste recycling products; (iii) diversifying revenue streams and financing mechanisms (polluter-pays-, cross-subsidy- and business-principles); and (iv) cost reduction and improved cost-effectiveness. We argue that in a PPP setup such as in Bahir Dar, a strong alliance between the municipality and private enterprise is important so that appropriate solutions for improved financial sustainability of a SWM system can be sought and implemented.

  13. Microsoft Word - Gardiner-Reedsport CX.doc

    Broader source: Energy.gov (indexed) [DOE]

    Substation Install a new 115-kV breaker with revenue metering-quality current transformers (CTc) and one 1600A disconnect switch. Tahkenitch Substation BPA plans to replace...

  14. CX-010162: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Revenue Meter Replacement at Oregon Trail Electric Co-op’s (OTEC's) West John Day Substation CX(s) Applied: B1.7 Date: 03/13/2013 Location(s): Oregon Offices(s): Bonneville Power Administration

  15. Estimating the maximum potential revenue for grid connected electricity storage : arbitrage and regulation.

    SciTech Connect (OSTI)

    Byrne, Raymond Harry; Silva Monroy, Cesar Augusto.

    2012-12-01T23:59:59.000Z

    The valuation of an electricity storage device is based on the expected future cash ow generated by the device. Two potential sources of income for an electricity storage system are energy arbitrage and participation in the frequency regulation market. Energy arbitrage refers to purchasing (stor- ing) energy when electricity prices are low, and selling (discharging) energy when electricity prices are high. Frequency regulation is an ancillary service geared towards maintaining system frequency, and is typically procured by the independent system operator in some type of market. This paper outlines the calculations required to estimate the maximum potential revenue from participating in these two activities. First, a mathematical model is presented for the state of charge as a function of the storage device parameters and the quantities of electricity purchased/sold as well as the quantities o ered into the regulation market. Using this mathematical model, we present a linear programming optimization approach to calculating the maximum potential revenue from an elec- tricity storage device. The calculation of the maximum potential revenue is critical in developing an upper bound on the value of storage, as a benchmark for evaluating potential trading strate- gies, and a tool for capital nance risk assessment. Then, we use historical California Independent System Operator (CAISO) data from 2010-2011 to evaluate the maximum potential revenue from the Tehachapi wind energy storage project, an American Recovery and Reinvestment Act of 2009 (ARRA) energy storage demonstration project. We investigate the maximum potential revenue from two di erent scenarios: arbitrage only and arbitrage combined with the regulation market. Our analysis shows that participation in the regulation market produces four times the revenue compared to arbitrage in the CAISO market using 2010 and 2011 data. Then we evaluate several trading strategies to illustrate how they compare to the maximum potential revenue benchmark. We conclude with a sensitivity analysis with respect to key parameters.

  16. Kittiwakes strategically reduce investment in replacement clutches

    E-Print Network [OSTI]

    Alvarez, Nadir

    Kittiwakes strategically reduce investment in replacement clutches Julien Gasparini1,*, Alexandre). In birds, egg production is lower in replacement clutches than in first clutches, but it is unknown whether the replacement clutch is produced) or from a strategic allocation of resources between the two breeding attempts

  17. Energy Efficient Buffer Cache Replacement Jianhui Yue

    E-Print Network [OSTI]

    Zhu, Yifeng

    Energy Efficient Buffer Cache Replacement Jianhui Yue Univ. of Maine, Orono jyue for buffer caching and thus cache replacement becomes critical. This paper investi- gates the tradeoff between these two interacting factors and proposes three energy-aware buffer cache replacement al- gorithm

  18. General Adaptive Replacement Policies Yannis Smaragdakis

    E-Print Network [OSTI]

    Smaragdakis, Yannis

    General Adaptive Replacement Policies Yannis Smaragdakis College of Computing Georgia Institute of Technology yannis@cc.gatech.edu ABSTRACT We propose a general scheme for creating adaptive replace- ment any two existing replacement policies so that the resulting policy provably can never perform worse

  19. Cooperative Determination on Cache Replacement Candidates

    E-Print Network [OSTI]

    Chin, Francis Y.L.

    Cooperative Determination on Cache Replacement Candidates for Transcoding Proxy Caching Keqiu Li1- mination on cache replacement candidates for transcoding proxies. An original model which determines cache replacement candidates on all can- didate nodes in a coordinated fashion with the objective of minimizing

  20. Replacement Diploma Request University of Massachusetts Lowell

    E-Print Network [OSTI]

    Massachusetts at Lowell, University of

    Replacement Diploma Request Mail to: University of Massachusetts Lowell Office of the Registrar 883. * Please use a separate form for each diploma request. * All replacement diplomas are University of Massachusetts Lowell diplomas. Replacement diplomas with the name of any predecessor institution

  1. Cache Replacement Policy Revisited Mohamed Zahran

    E-Print Network [OSTI]

    Zahran, Mohamed M.

    Cache Replacement Policy Revisited Mohamed Zahran Electrical Engineering Department City University of New York mzahran@ccny.cuny.edu Abstract Cache replacement policy is a major design parameter of any memory hierarchy. The efficiency of the replace- ment policy affects both the hit rate and the access la

  2. Article ID #eqr106 REPLACEMENT STRATEGIES

    E-Print Network [OSTI]

    Popova, Elmira

    Article ID #eqr106 REPLACEMENT STRATEGIES Elmira Popova Associate Professor, Department)-296-5795 e-mail: popovai@seattleu.edu Corresponding Contributor: Elmira Popova Keywords: Replacement Policies define what is a replacement policy for a system that fails randomly in time and its main characteristics

  3. Replacement Diploma Request University of Massachusetts Lowell

    E-Print Network [OSTI]

    Massachusetts at Lowell, University of

    Replacement Diploma Request Mail to: University of Massachusetts Lowell Office of the Registrar 220. * Please use a separate form for each diploma request. * All replacement diplomas are University of Massachusetts Lowell diplomas. Replacement diplomas with the name of any predecessor institution

  4. Type-Logical Hyperedge Replacement Grammars

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Type-Logical and Hyperedge Replacement Grammars Draft Richard Moot LaBRI (CNRS), INRIA Bordeaux SW2009 #12;CONTENTS 1 Introduction 1 2 Hyperedge Replacement Grammars 3 2.1 Hypergraphs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.2 Hyperedge Replacement . . . . . . . . . . . . . . . . . . . . . . . 4 2.3 Hyperedge

  5. PeopleAdmin Staff Straight Replacement

    E-Print Network [OSTI]

    Hutcheon, James M.

    1 PeopleAdmin ­ Staff Straight Replacement Guide #12;2 The staff straight replacement module will be used by hiring managers to request vacant, benefited positions be advertisedAdmin system, you will see this view. To begin the staff straight replacement process, you should click BEGIN

  6. Insights from Smart Meters: The Potential for Peak-Hour Savings from Behavior-Based Programs

    E-Print Network [OSTI]

    Todd, Annika

    2014-01-01T23:59:59.000Z

    2014.  Insights from Smart  Meters: The Potential for Peak available data captured by smart meters and other sources,series Insights from Smart Meters. DRAFT – DO NOT CIRCULATE

  7. Verifying energy savings with minimal metered data: The Hunter heat pump analysis

    SciTech Connect (OSTI)

    Parker, S.A.

    1995-03-01T23:59:59.000Z

    In November 1992, Hunter Army Air Field (AAF) completed the installation of 489 air-source heat pumps -- a new heat pump and air-handling unit for each residence. The air-source heat pumps replaced older, less efficient, air-conditioning systems, fuel oil-fired furnaces, and fan coil units. Hunter AAF originally contacted to upgrade the old family housing heating, ventilating, and air-conditioning (HVAC) systems with high efficiency air-conditioning systems and natural gas furnaces, but an alternative proposal and following energy studies indicated that heat pumps were a more life-cycle cost-effective alternative. Six months after the heat pumps were installed, Hunter`s energy bills appeared to be increasing, not decreasing as expected. In early 1994, Pacific Northwest Laboratory` (PNL) began an analysis to determine if there were any energy savings resulting from the heat pump installation as predicted by previous energy studies. The problem is that the HVAC systems are not specifically submetered to support verifying the resulting energy savings and, as is the case with most federal facilities, even the homes are not individually metered. Savings verification needed to be accomplished with die existing and available metered data. This data consisted primarily of monthly electric submeter readings from the two housing subdivision meters, historical fuel oil delivery records for family housing, and monthly base-wide electric bills. The objective of the study is to verify the change in energy consumption in family housing and, to the extent possible, identify how much of the change in consumption is attributable to the new HVAC system and how much is probably attributable to other factors, such as the weather.

  8. NREL: Energy Storage - BLAST for Behind-the-Meter Applications...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lite (BLAST-BTM Lite) provides a quick, user-friendly tool to size behind-the-meter energy storage devices used on site by utility customers for facility demand charge...

  9. Smart Meters Offer 'Instant Gratification;' Help Houston Homeowners...

    Broader source: Energy.gov (indexed) [DOE]

    Diorio explains to KPRC Local 2 News how much she's saved with her recently installed smart meter, which allows her to see her savings in real time. Houston resident Ruth...

  10. Demand Response and Smart Metering Policy Actions Since the Energy...

    Broader source: Energy.gov (indexed) [DOE]

    This report represents a review of policy developments on demand response and other related areas such as smart meters and smart grid. It has been prepared by the Demand Response...

  11. ODUSD (I&E) Facilities Energy Program Advanced Metering Policy

    Broader source: Energy.gov [DOE]

    Presentation—given at the Spring 2013 Federal Utility Partnership Working Group (FUPWG) meeting—covers the U.S. Department of Defense's (DoD's) metering policy, including implementation challenges and utility partnerships.

  12. Smart Meters Helping Oklahoma Consumers Save Hundreds During...

    Broader source: Energy.gov (indexed) [DOE]

    meters give consumers real-time information on how their energy use affects their energy costs. With a two-tiered pricing system, you get a discount during lower usage...

  13. Down to the Meter: Localized Vehicle Pollution Matters

    E-Print Network [OSTI]

    Houston, Douglas; Wu, Jun; Ong, Paul; Winer, Arthur

    2006-01-01T23:59:59.000Z

    Near-Roadway Vehicle Pollution,” American Journal of Publicfor Vehicle-Related Air Pollution Exposure in Minority andMeter: Localized Vehicle Pollution Matters B Y D O U G L A S

  14. 25 years ago: the official farewell to the meter

    E-Print Network [OSTI]

    Thomas Schucker

    2008-10-20T23:59:59.000Z

    On october 21st 1983 took place in S\\`evres on the western outskirts of Paris the official funeral of the meter. With it the notion of distance as a physical observable was buried.

  15. Value creation and value capture of advanced electricity meter information

    E-Print Network [OSTI]

    Oesterlin, Ulf

    2011-01-01T23:59:59.000Z

    Advanced or smart metering has been a hot topic in the electricity community for several years. Despite the excitement about the technology, few business cases are actually able to justify the investment cost. One reason ...

  16. advanced metering techniques: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Assessment of Demand Response and Advanced Metering Power Transmission, Distribution and Plants Websites...

  17. Amendment 80 vessel replacement 1 Implementation and of Amendment 80 Vessel Replacement Provisions

    E-Print Network [OSTI]

    Amendment 80 vessel replacement 1 Implementation and of Amendment 80 Vessel Replacement Provisions vessels to use non-qualifying vessels in the sector, thus allowing replacement of a lost qualifying vessel of the CRP ambiguous as to whether replacement of qualifying vessels with non-qualifying vessels

  18. Shared Signals: Using Existing Facility Meters for Energy Savings Verification

    E-Print Network [OSTI]

    McBride, J. R.; Bohmer, C. J.; Price, S. D.; Carlson, K.; Lopez, J.

    of metering. Facility engineers wonder whether existing meters can be used for savings verification purposes. They want to know whether an existing energy management and control system (EMCS) can serve double duty and be used for savings verification... an existing EMCS for energy savings verification purposes is even more complex. While at first glance the idea of using an existing EMCS for energy savings verification purposes seems absolutely reasonable, the practicality of the situation must...

  19. November 15, 2012 Webinar: Exploring Opportunities for Energy Efficiency as a Revenue Stream in the Forward Capacity Markets

    Broader source: Energy.gov [DOE]

    November 15, 2012 Webinar: Exploring Opportunities for Energy Efficiency as a Revenue Stream in the Forward Capacity Markets, Better Buildings Neighborhood Program; regional transmission organizations (RTOs)

  20. Smart-Metering for Monitoring Building Power Distribution Network using Instantaneous Phasor Computations of Electrical Signals

    E-Print Network [OSTI]

    K.R., Krishnanand

    2013-01-01T23:59:59.000Z

    Smart-Metering for Monitoring Building Power Distributionimplementable for smart-meters for a building. Eachcontrol node of a building so as to make smart decisions.

  1. Optimal scheduling for replacing perimeter guarding unmanned ...

    E-Print Network [OSTI]

    2014-08-20T23:59:59.000Z

    difference between charging batteries, automatically replacing batteries [11] or ... the discussion below to the use of batteries and battery charge, without loss of ...

  2. LED Replacements for Linear Fluorescent Lamps Webcast

    Broader source: Energy.gov [DOE]

    In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting...

  3. Smart Meter Investments Support Rural Economy in Arkansas

    Broader source: Energy.gov (indexed) [DOE]

    by Woodruff Electric Cooperative. 2 replacing aging equipment, tree trimming, and other preventive maintenance. Such activities help the utility reduce the frequency and duration...

  4. Differentially Private Smart Metering with Battery Michael Backes1,2

    E-Print Network [OSTI]

    Differentially Private Smart Metering with Battery Recharging Michael Backes1,2 and Sebastian meters to take fine-grained readings of energy usage. These smart meters enable flexible time- of to a min- imum. 1 Introduction The energy industry has recently begun using smart meters to take fine

  5. Survivable Smart Grid Communication: Smart-Meters Meshes to the Rescue

    E-Print Network [OSTI]

    Tague, Patrick

    Survivable Smart Grid Communication: Smart-Meters Meshes to the Rescue Arjun P. Athreya and Patrick flattening process. This process involves smart-meters and other disaster surviving elements of higher system as a function of outage area, smart-meter density and smart-meter's neighborhood size. The results from

  6. Managing Cancellations and No-shows of Reservations with Overbooking to Increase Resource Revenue

    E-Print Network [OSTI]

    Melbourne, University of

    to different customers, and to peri- odically update the prices in response to market demands. Therefore gains an extra 6­9% in the total net revenue. 1 Introduction Grid [4] technology enables the aggregation that provides a mechanism for regulating demand and supply of resources, and calculates pricing policies based

  7. Revenue Maximization in Reservation-based Online Advertising Through Dynamic Inventory

    E-Print Network [OSTI]

    Tomkins, Andrew

    Revenue Maximization in Reservation-based Online Advertising Through Dynamic Inventory Management inventory on content sites owned by publishers (e.g., CNN, amazon, etc.). Sales representatives, acting on behalf of publishers, sell inventory (impression) bundles of various types (text, video, multimedia, etc

  8. A Study of Revenue Flows in Packet Networks under Multiple Administrative Domains

    E-Print Network [OSTI]

    A Study of Revenue Flows in Packet Networks under Multiple Administrative Domains Saadullah Tareenx that they usually only consider a single network and always consider a single administrative domain when for a detailed study of more realistic networks under multiple administrative domains. The interac- tions between

  9. Assessing the Impact of Heat Rejection Technology on CSP Plant Revenue: Preprint

    SciTech Connect (OSTI)

    Wagner, M. J.; Kutscher, C. F.

    2010-10-01T23:59:59.000Z

    This paper explores the impact of cooling technology on revenue for hybrid-cooled plants with varying wet cooling penetration for four representative locations in the American Southwest. The impact of ACC design-point initial temperature difference (ITD - the difference between the condensing steam temperature and ambient dry-bulb) is also included in the analysis.

  10. Advanced Metering Implementations - A Perspective from Federal Sector

    SciTech Connect (OSTI)

    Eaarni, Shankar

    2014-08-11T23:59:59.000Z

    Federal mandate (EPACT 2005) requires that federal buildings install advanced electrical meters-meters capable of providing data at least daily and measuring the consumption of electricity at least hourly. This work presents selected advanced metering implementations to understand some of the existing practices related to data capture and to understand how the data is being translated into information and knowledge that can be used to improve building energy and operational performance to meet federal energy reduction mandates. This study highlights case studies to represent some of the various actions that are being taken based on the data that are being collected to improve overall energy performance of these buildings. Some of these actions include- individualized tenant billing and energy forecasting, benchmarking, identifying energy conservation measures, measurement and verification.

  11. Net Metering and Interconnection Procedures-- Incorporating Best Practices

    SciTech Connect (OSTI)

    Jason Keyes, Kevin Fox, Joseph Wiedman, Staff at North Carolina Solar Center

    2009-04-01T23:59:59.000Z

    State utility commissions and utilities themselves are actively developing and revising their procedures for the interconnection and net metering of distributed generation. However, the procedures most often used by regulators and utilities as models have not been updated in the past three years, in which time most of the distributed solar facilities in the United States have been installed. In that period, the Interstate Renewable Energy Council (IREC) has been a participant in more than thirty state utility commission rulemakings regarding interconnection and net metering of distributed generation. With the knowledge gained from this experience, IREC has updated its model procedures to incorporate current best practices. This paper presents the most significant changes made to IREC���¢��������s model interconnection and net metering procedures.

  12. Vehicle Technologies and Bus Fleet Replacement Optimization

    E-Print Network [OSTI]

    Bertini, Robert L.

    1 Vehicle Technologies and Bus Fleet Replacement Optimization: problem properties and sensitivity: R41 #12;2 Abstract This research presents a bus fleet replacement optimization model to analyze hybrid and conventional diesel vehicles, are studied. Key variables affecting optimal bus type

  13. Entropy Meters and the Entropy of Non-extensive Systems

    E-Print Network [OSTI]

    Elliott H. Lieb; Jakob Yngvason

    2014-03-30T23:59:59.000Z

    In our derivation of the second law of thermodynamics from the relation of adiabatic accessibility of equilibrium states we stressed the importance of being able to scale a system's size without changing its intrinsic properties. This leaves open the question of defining the entropy of macroscopic, but unscalable systems, such as gravitating bodies or systems where surface effects are important. We show here how the problem can be overcome, in principle, with the aid of an `entropy meter'. An entropy meter can also be used to determine entropy functions for non-equilibrium states and mesoscopic systems.

  14. Smart Meters and a Smarter Grid | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently AskedEnergyIssues DOE's Nuclear EnergySmart Meters and a Smarter Grid Smart Meters

  15. Metering and the New Federal Requirements of Energy Policy Act 2005

    E-Print Network [OSTI]

    Ream, A.; Verdict, M.

    2006-01-01T23:59:59.000Z

    agencies to meter electricity use in all federal buildings by Oct. 1, 2012 using advanced meters or metering devices that provide data at least daily. Six months after the enactment of EPAct, DOE’s Federal Energy Management Program, or FEMP... Station, Texas ABSTRACT Section 103 of the Energy Policy Act of 2005 (EPAct 2005) (1) mandates the installation of meters and advanced electric meters on all Federal Buildings by 2012 using guidelines developed by the US Department of Energy...

  16. Page Replacement Algorithms To use a simulation for evaluating various page replacement algorithms studied in class.

    E-Print Network [OSTI]

    Stojmenovic, Ivan

    Operating Systems CSI3131 Lab 4 Winter 2011 Page Replacement Algorithms Objective To use a simulation for evaluating various page replacement algorithms studied in class. Description (Please read to compare the performance of each page replacement algorithm. The constructor of this class contains

  17. VISITOR PARKING Pay station parking meters are available around

    E-Print Network [OSTI]

    temporary parking needs. Daily scratch-off permits are available in advance from Parking Services. LOT METER PAY STATION RATES (SUMMER RATES MAY BE DISCOUNTED) HOW DO I GET A PERMIT? When parking on campus, a CSM parking permit is required Monday through Friday, from 7AM until 5 PM. Permits authorize parking

  18. Privacy-friendly Energy-metering via Homomorphic Encryption

    E-Print Network [OSTI]

    Jacobs, Bart

    Privacy-friendly Energy-metering via Homomorphic Encryption Flavio D. Garcia and Bart Jacobs and consumption is one of the goals. Accurate usage data is important for such a better match. So-called smart by the utility sector. For instance, in April 2009 the Senate in the Netherlands has refused to pass a bill

  19. Grain Drill Metering Systems and the Need for Calibration

    E-Print Network [OSTI]

    Holland, Jeffrey

    Grain Drill Metering Systems and the Need for Calibration Purdue extension ABE-126-W Purdue down an average seed- ing rate. Calibration is often overlooked as a means of im- proving machine performance and controlling input costs. Calibration is simply the process of verifying the rate of delivery

  20. Embedded Cyber-Physical Anomaly Detection in Smart Meters

    E-Print Network [OSTI]

    vulnerabilities that arise from deployment of local cyber-physical attacks at a smart metering location and physical domains. 1 Introduction Limitations of today's power networks, combined with the need we address the risk of manipula- tions at the end-user level, even when a trusted infrastructure

  1. Securing Energy Metering Software with Automatic Source Code Correction

    E-Print Network [OSTI]

    Neves, Nuno

    of energy production have been fostering the monitoring and analy- sis of electricity consumption for the country [7]. Many of the meters provide energy consumption informa- tion that can be stored and processed in graphical format, analyze consumption trends, identify peak demand, and raise alarms about anomalous

  2. Using Wireless Power Meters to Measure Energy Use of

    E-Print Network [OSTI]

    Culler, David E.

    by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Technology Development, Building-term energy used by a large sample of devices due to the difficulty and expense of collecting deviceUsing Wireless Power Meters to Measure Energy Use of Miscellaneous and Electronic Devices

  3. Personal energy metering Simon Hay, Andrew Rice and Andy Hopper

    E-Print Network [OSTI]

    Cambridge, University of

    is true of energy consumption in shared buildings: in a house of four where all bills are split systems installed in many buildings today can be used to apportion energy consumption between users energy meter is a low cost, low infras- tructure location system that can be deployed on a truly global

  4. Replacement solvents for use in chemical synthesis

    DOE Patents [OSTI]

    Molnar, Linda K. (Philadelphia, PA); Hatton, T. Alan (Sudbury, MA); Buchwald, Stephen L. (Newton, MA)

    2001-05-15T23:59:59.000Z

    Replacement solvents for use in chemical synthesis include polymer-immobilized solvents having a flexible polymer backbone and a plurality of pendant groups attached onto the polymer backbone, the pendant groups comprising a flexible linking unit bound to the polymer backbone and to a terminal solvating moiety. The polymer-immobilized solvent may be dissolved in a benign medium. Replacement solvents for chemical reactions for which tetrahydrofuran or diethyl may be a solvent include substituted tetrahydrofurfuryl ethers and substituted tetrahydro-3-furan ethers. The replacement solvents may be readily recovered from the reaction train using conventional methods.

  5. Grand Coulee Transmission Line Replacement Project

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    by the Bureau of Reclamation to design and construct six new 500-kV overhead transmission lines at Grand Coulee Dam. BPA will replace the existing underground transmission...

  6. Organic agriculture cannot replace conventional agriculture

    E-Print Network [OSTI]

    Kolokolnikov, Theodore

    Organic agriculture cannot replace conventional agriculture Sina Adl , David Iron and Theodore Agriculture | Pathogen Dispersal Introduction Organic farming [1, 2] is gaining in popularity in Eu- rope, because or- ganic agriculture avoids using environmentally harmful chem- icals that pollute soil

  7. Marin County- Wood Stove Replacement Rebate Program

    Broader source: Energy.gov [DOE]

    The County of Marin has created a rebate program to encourage homeowners to remove or replace non-EPA certified wood-burning heaters (wood stoves and fireplace inserts) with cleaner burning stoves...

  8. Evaluation of alternative sign replacement strategies 

    E-Print Network [OSTI]

    McCaleb, James Bradley

    1996-01-01T23:59:59.000Z

    values and guidelines will have a significant impact on TXDOT. The objective of this thesis was to determine the most cost effective strategy for TXDOT to implement in replacing traffic signs that do not meet the expected minimum retroreflectivity values...

  9. Beyond the Replacement Paradigm: Smart Lighting

    E-Print Network [OSTI]

    Salama, Khaled

    Switches · Smart Building & Grid Interfaces · Efficient full spectrum LEDs without droop · Versatile, low - Visible Light Communications Integration of smart fixtures, networked sensors and control systemsBeyond the Replacement Paradigm: Smart Lighting Robert F. Karlicek, Jr. Director, Smart Lighting

  10. Federal offshore statistics: 1992. Leasing, exploration, production, and revenues as of December 31, 1992

    SciTech Connect (OSTI)

    Francois, D.K.

    1993-12-31T23:59:59.000Z

    The Outer Continental Shelf Lands Act, enacted in 1953 and amended several times, charges the Secretary of the Interior with the responsibility for administering and managing mineral exploration and development of the outer continental shelf, as well as for conserving its natural resources. This report documents the following: Federal offshore lands; offshore leasing activity and status; offshore development activity; offshore production of crude oil and natural gas; Federal offshore oil and natural gas sales volume and royalties; revenue from Federal offshore leases; disbursement of Federal offshore revenue; reserves and resource estimates of offshore oil and natural gas; oil pollution in US and international waters; and international activities and marine minerals. 11 figs., 83 tabs.

  11. A replacement consideration in conductor economics

    E-Print Network [OSTI]

    Ciniglio Manzzo, Orlando Antonio

    1977-01-01T23:59:59.000Z

    A REPLACEMENT CONSIDERATION IN CONDUCTOR ECONOMICS A Thesis by ORLANDO ANTONIO CINIGLIO MANZZO Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE August... 1977 Major Subject: Electrical Engineering A REPLACEMENT CONSIDERATION IN CONDUCTOR ECONOMICS A Thesis ORLANDO ANTONIO CINIGLIO MANZZO Approved as to style and content by: (Chairman of Committee) // f, ', , / j (Head of Depart'ment) Member...

  12. An optimal replacement problem in aluminum production

    E-Print Network [OSTI]

    Spanks, Lisa Marie

    1992-01-01T23:59:59.000Z

    AN OPTIMAL REPLACEMENT PROBLEM IN ALUMINUM PRODUCTION Thesis by LISA MARIE SPANKS Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE May 1992... Major Subject: Industrial Engineering AN OPTIMAL REPLACEMENT PROBLEM IN ALUMINUM PRODUCTION Thesis by LISA MARIE SPANKS Approved as to style and content by: Richard M. Feldman (Chair of Committee) James H. Matis (Member) ryan L. Deuermey r...

  13. A replaceable reflective film for solar concentrators

    SciTech Connect (OSTI)

    Not Available

    1991-09-01T23:59:59.000Z

    The 3M Company manufactures a silvered acrylic film called ECP-305 that is regarded as the preferred reflective film for use on stretched-membrane heliostats. However, ECP-305 will degrade in time, due to both corrosion of the silver layer and delamination at the film's silver-to-acrylic interface, and will eventually need to be replaced. 3M uses a very aggressive adhesive on this film, and once it is laminated, replacement is very difficult. The purpose of this investigation was the development of a replaceable reflector, a reflective film that can be easily removed and replaced. A replaceable reflector was successfully configured by laminating ECP-305 to the top surface of a smooth, dimensionally stable polymer film, with a removable adhesive applied to the underside of the polymer film. Several stages of screening and testing led to the selection of a 0.010-inch thick polycarbonate (GE 8030) as the best polymer film and a medium tack tape (3M Y-9425) was selected as the best removable adhesive. To demonstrate the feasibility of the replaceable reflector concept and to provide a real-time field test, the chosen construction was successfully applied to the 50-m{sup 2} SKI heliostat at the Central Receiver Test Facility at Sandia National Laboratories in Albuquerque. 4 refs., 13 figs., 7 tabs.

  14. Esthetically Designed Municipal PV System Maximizes Energy Production and Revenue Return

    Broader source: Energy.gov [DOE]

    In late 2008, the City of Sebastopol, CA installed a unique 42 kW grid-interactive photovoltaic (PV) system to provide electricity for pumps of the Sebastopol municipal water system. The resulting innovative Sun Dragon PV system, located in a public park, includes design elements that provide optimized electrical performance and revenue generation for the energy produced while also presenting an artistic and unique appearance to park visitors.

  15. Empirical study on the Korean treasury auction focusing on the revenue comparison in multiple versus single price auction 

    E-Print Network [OSTI]

    Kang, Boo-Sung

    2006-04-12T23:59:59.000Z

    This dissertation pursues to find an answer empirically to the question of the revenue ranking between the multiple price auction and the single price auction. I also attempt to get empirical clues in terms of the efficiency ...

  16. Dead-time compensation for a logarithmic display rate meter

    DOE Patents [OSTI]

    Larson, John A. (Aurora, IL); Krueger, Frederick P. (Aurora, IL)

    1988-09-20T23:59:59.000Z

    An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events.

  17. Smart Meter Privacy: A Utility-Privacy Framework

    E-Print Network [OSTI]

    Rajagopalan, S Raj; Mohajer, Soheil; Poor, H Vincent

    2011-01-01T23:59:59.000Z

    End-user privacy in smart meter measurements is a well-known challenge in the smart grid. The solutions offered thus far have been tied to specific technologies such as batteries or assumptions on data usage. Existing solutions have also not quantified the loss of benefit (utility) that results from any such privacy-preserving approach. Using tools from information theory, a new framework is presented that abstracts both the privacy and the utility requirements of smart meter data. This leads to a novel privacy-utility tradeoff problem with minimal assumptions that is tractable. Specifically for a stationary Gaussian Markov model of the electricity load, it is shown that the optimal utility-and-privacy preserving solution requires filtering out frequency components that are low in power, and this approach appears to encompass most of the proposed privacy approaches.

  18. , Analysis of U.S. Net Metering and Interconnection Policy

    SciTech Connect (OSTI)

    Haynes, Rusty; Cook, Chris

    2006-07-01T23:59:59.000Z

    Historically, the absence of interconnection standards has been one of the primary barriers to the deployment of distributed generation (DG) in the United States. Although significant progress in the development of interconnection standards was achieved at both the federal and state levels in 2005, interconnection policy and net-metering policy continue to confound regulators, lawmakers, DG businesses, clean-energy advocates and consumers. For this reason it is critical to keep track of developments related to these issues. The North Carolina Solar Center (NCSC) is home to two Interstate Renewable Energy Council (IREC) projects -- the National Interconnection Project and the Database of State Incentives for Renewable Energy (DSIRE). This paper will present the major federal and state level policy developments in interconnection and net metering in 2005 and early 2006. It will also present conclusions based an analysis of data collected by these two projects.

  19. The practical equity implications of advanced metering infrastructure

    SciTech Connect (OSTI)

    Felder, Frank A.

    2010-07-15T23:59:59.000Z

    Reductions in advanced metering costs and the efficiency benefits of dynamic pricing make a compelling case to adopt both, particularly for industrial and commercial facilities. Regulators should seriously consider such policies for residential households as well. Regulators can take meaningful steps to mitigate, if not entirely offset, the possibility that some low-income ratepayers may have higher electricity bills with AM and DP. (author)

  20. Integration of Behind-the-Meter PV Fleet Forecasts into Utility...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Integration of Behind-the-Meter PV Fleet Forecasts into Utility Grid System Operations Integration of Behind-the-Meter PV Fleet Forecasts into Utility Grid System Operations Clean...

  1. Helping New Hampshire Achieve Its 25 x 25 Goal Renewable Energy Incentives, Energy Metering, and

    E-Print Network [OSTI]

    Lotko, William

    Helping New Hampshire Achieve Its 25 x 25 Goal Renewable Energy Incentives, Energy Metering................................................................................................................. 7 2. RENEWABLE ENERGY: FINANCING INCENTIVES......................................... 8 2.1 LOANS............................................................ 12 3. RENEWABLE ENERGY: PRODUCTION INCENTIVES................................... 14 3.1 NET METERING

  2. LONG TERM FILE MIGRATION - PART II: FILE REPLACEMENT ALGORITHMS

    E-Print Network [OSTI]

    Jay Smith, Alan

    2011-01-01T23:59:59.000Z

    MIGRATION· PART II: FILE REPLACEMENT ALGORITHMS Alan Jaymay vary even though replacement fi~~d the pa~ameter value PIe N - P ;, RT I r:. fILE REPLACEMENT ALGORITHMS. I.lan ~1ar

  3. REPLACEMENT/STALE DATED CHEQUE REQUEST FORM Date: ____________________________ Student Number: _________________________

    E-Print Network [OSTI]

    Sinnamon, Gordon J.

    REPLACEMENT/STALE DATED CHEQUE REQUEST FORM Date: ____________________________ Student: _________________________ Cheque Date: _____________________ CHEQUE AMOUNT: ________________________ REASON FOR REPLACEMENT Building at the address below. Please indicate how you would like to receive your replacement cheque

  4. Lambek Grammars, Tree Adjoining Grammars and Hyperedge Replacement Grammars

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Lambek Grammars, Tree Adjoining Grammars and Hyperedge Replacement Grammars Richard Moot La (tree generating) hyperedge replacement grammars as an intermediate step. As a consequence both, using hyperedge replacement grammars as an intermediate step. 2 Tree Adjoining Grammars and Hyperedge

  5. Naval Undersea Warfare Center Division Newport utilities metering, Phase 1

    SciTech Connect (OSTI)

    Carroll, D.M.

    1992-11-01T23:59:59.000Z

    Pacific Northwest Laboratory developed this report for the US Navy's Naval Undersea Warfare Center Division Newport, Rhode Island (NUWC). The purpose of the report was to review options for metering electricity and steam used in the NUWC compound, and to make recommendations to NUWC for implementation under a follow-on project. An additional NUWC concern is a proposed rate change by the servicing utility, Newport Electric, which would make a significant shift from consumption to demand billing, and what effect that rate change would have on the NUWC utility budget. Automated, remote reading meters are available which would allow NUWC to monitor its actual utility consumption and demand for both the entire NUWC compound and by end-use in individual buildings. Technology is available to perform the meter reads and manipulate the data using a personal computer with minimal staff requirement. This is not meant to mislead the reader into assuming that there is no requirement for routine preventive maintenance. All equipment requires routine maintenance to maintain its accuracy. While PNL reviewed the data collected during the site visit, however, it became obvious that significant opportunities exist for reducing the utility costs other than accounting for actual consumption and demand. Unit costs for both steam and electricity are unnecessarily high, and options are presented in this report for reducing them. Additionally, NUWC has an opportunity to undertake a comprehensive energy resource management program to significantly reduce its energy demand, consumption, and costs.

  6. Naval Undersea Warfare Center Division Newport utilities metering, Phase 1

    SciTech Connect (OSTI)

    Carroll, D.M.

    1992-11-01T23:59:59.000Z

    Pacific Northwest Laboratory developed this report for the US Navy`s Naval Undersea Warfare Center Division Newport, Rhode Island (NUWC). The purpose of the report was to review options for metering electricity and steam used in the NUWC compound, and to make recommendations to NUWC for implementation under a follow-on project. An additional NUWC concern is a proposed rate change by the servicing utility, Newport Electric, which would make a significant shift from consumption to demand billing, and what effect that rate change would have on the NUWC utility budget. Automated, remote reading meters are available which would allow NUWC to monitor its actual utility consumption and demand for both the entire NUWC compound and by end-use in individual buildings. Technology is available to perform the meter reads and manipulate the data using a personal computer with minimal staff requirement. This is not meant to mislead the reader into assuming that there is no requirement for routine preventive maintenance. All equipment requires routine maintenance to maintain its accuracy. While PNL reviewed the data collected during the site visit, however, it became obvious that significant opportunities exist for reducing the utility costs other than accounting for actual consumption and demand. Unit costs for both steam and electricity are unnecessarily high, and options are presented in this report for reducing them. Additionally, NUWC has an opportunity to undertake a comprehensive energy resource management program to significantly reduce its energy demand, consumption, and costs.

  7. The effects between two slotted plate flow meter under single, two, three components flow condition

    E-Print Network [OSTI]

    Park, Sang Hyan

    2005-02-17T23:59:59.000Z

    suggested a universal calibration for the slotted flow meter under various situations using only the Euler number (Eu) and the ratio of ? = AAslot pipe The calibration curve of the slotted meter?s flow coefficient KY versus Euler number was obtained..., or Three Component Flow Conditions. (December 2004) Sang Hyun Park, B.S., Yonsei University, Republic of Korea Chair of Advisory Committee: Dr. Gerald L. Morrison In previous work on the slotted flow meter, repeatibility and reproducibility were studied...

  8. Status of Net Metering: Assessing the Potential to Reach Program Caps (Poster)

    SciTech Connect (OSTI)

    Heeter, J.; Bird, L.; Gelman, R.

    2014-10-01T23:59:59.000Z

    Several states are addressing the issue of net metering program caps, which limit the total amount of net metered generating capacity that can be installed in a state or utility service territory. In this analysis, we examine net metering caps to gain perspective on how long net metering will be available in various jurisdictions under current policies. We also surveyed state practices and experience to understand important policy design considerations.

  9. Status of Net Metering: Assessing the Potential to Reach Program Caps

    SciTech Connect (OSTI)

    Heeter, J.; Gelman, R.; Bird, L.

    2014-09-01T23:59:59.000Z

    Several states are addressing the issue of net metering program caps, which limit the total amount of net metered generating capacity that can be installed in a state or utility service territory. In this analysis, we examine net metering caps to gain perspective on how long net metering will be available in various jurisdictions under current policies. We also surveyed state practices and experience to understand important policy design considerations.

  10. Video game console usage and national energy consumption: Results from a field-metering study

    E-Print Network [OSTI]

    Desroches, Louis-Benoit

    2013-01-01T23:59:59.000Z

    with their free energy audit program. Meters were installedinstalled as part of an energy audit program. Users may be

  11. Behavioral/Systems/Cognitive Tagging the Neuronal Entrainment to Beat and Meter

    E-Print Network [OSTI]

    and meter perception (Large and Kolen, 1994; van Noorden and Moelants, 1999; Large, 2008) proposes that beat

  12. United States- Land Based and Offshore Annual Average Wind Speed at 100 Meters

    Broader source: Energy.gov [DOE]

    Full-size, high resolution version of the 100-meter land-based and offshore wind speed resource map.

  13. An investigation of effects of flow conditioning on straight tube Coriolis meter

    E-Print Network [OSTI]

    Shukla, Shashank

    2009-05-15T23:59:59.000Z

    metering can be very beneficial for the following1, 2. 1.1.1 Layout of production facilities Use of multiphase meters reduces the hardware needed for onshore, offshore topside and offshore subsea applications by eliminating the need of dedicated test... Coriolis meters are essentially aeroelastic devices; and as such involve coupled dynamic interaction of fluid dynamics and structural system. The Coriolis meter basically consists of a tube conveying fluid (lying in one plane and clamped at its ends...

  14. Bio:Matthew Andrews is a Distinguished Member of Technical Staff at Alcatel-Lucent Bell Labs. His research interests include combinatorial optimization, operations research and data analytics, with applications to resource allocation and revenue managemen

    E-Print Network [OSTI]

    Columbia University

    , with applications to resource allocation and revenue management in wireless networks, energy-efficient

  15. Avoiding a Train Wreck: Replacing Old Coal Plants with Energy...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Avoiding a Train Wreck: Replacing Old Coal Plants with Energy Efficiency, August 2011 Avoiding a Train Wreck: Replacing Old Coal Plants with Energy Efficiency, August 2011 This...

  16. Boron-10 Neutron Detectors for Helium-3 Replacement

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Homeland Security & Defense Boron-10 Neutron Detectors for Helium-3 Replacement Boron-10 Neutron Detectors for Helium-3 Replacement As part of the Laboratory's national security...

  17. Quenching and Partitioning Process Development to Replace Hot...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and Partitioning Process Development to Replace Hot Stamping of High-Strength Automotive Steel Quenching and Partitioning Process Development to Replace Hot Stamping of...

  18. eMeter: An interactive energy monitor In this work, we propose an interactive load monitoring

    E-Print Network [OSTI]

    level. Therefore, we extended the capabilities of a smart elec- tricity meter and developed a mobile interfaces Merging smart meters and mobile devices Timely consumption feedback and guidance with re- spectComp 2009, Sep 30 ­ Oct 3, 2009, Orlando, FL, USA #12;household once smart meters are introduced. We wanted

  19. Evaluating Government's Policies on Promoting Smart Metering Diffusion in Retail Electricity Markets via

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    Evaluating Government's Policies on Promoting Smart Metering Diffusion in Retail Electricity on promoting smart metering in the U.K. retail electricity market. We break down the policy into four possible recommendations for the energy mar- ket is the adoption of smart metering technology, which, in addition

  20. Efficient and Secure Wireless Communications for Advanced Metering Infrastructure in Smart Grids

    E-Print Network [OSTI]

    Qiu, Robert Caiming

    1 Efficient and Secure Wireless Communications for Advanced Metering Infrastructure in Smart Grids metering infrastructure (AMI) [3] is a key task in smart grid [6] [4]. In such a system, each power user is equipped with a smart meter with the capability of two- way communications, which can monitor the power

  1. A Distortion-Theoretic Perspective for Redundant Metering Security in a Smart Grid

    E-Print Network [OSTI]

    Kundur, Deepa

    A Distortion-Theoretic Perspective for Redundant Metering Security in a Smart Grid Mustafa El--In a smart grid environment some customers employ third-party meters and terminals for integrity verification of the smart meter power measurements reported by the electric utility company. We address the security issues

  2. Missing Data Handling for Meter Data Management System Ru-Sen Jeng1

    E-Print Network [OSTI]

    Chen, Ling-Jyh

    Applications]: Types of Systems-- Decision support (e.g., MIS) Keywords Missing data, Smart meter, MDMS 1-scale deployments. As a consequence, conventional missing data handling methods are not applicable to smart meterMissing Data Handling for Meter Data Management System Ru-Sen Jeng1 , Chien-Yu Kuo1 , Yao-hua Ho1

  3. Neighborhood Watch: Security and Privacy Analysis of Automatic Meter Reading Systems

    E-Print Network [OSTI]

    Xu, Wenyuan

    gruteser@winlab.rutgers.edu ABSTRACT Research on smart meters has shown that fine-grained en- ergy usage data poses privacy risks since it allows inferences about activities inside the home. While smart meter-1-4503-1651-4/12/10 ...$15.00. 1. INTRODUCTION Much attention has been devoted to smart meters, as they play a central role

  4. Too expensive to meter: The influence of transaction costs in transportation and

    E-Print Network [OSTI]

    Odlyzko, Andrew M.

    . "Smart meters" that charge different prices, de- pending either on time of day, or, in even moreToo expensive to meter: The influence of transaction costs in transportation and communication in their homes electrical energy too cheap to meter, ... It is not too much to expect that our children will know

  5. Capacity Analysis of a Wireless Backhaul for Metering in the Smart Grid

    E-Print Network [OSTI]

    Namboodiri, Vinod

    Capacity Analysis of a Wireless Backhaul for Metering in the Smart Grid Babak Karimi and Vinod. With the introduction of AMI technology, two-way communication between a smart meter (SM) and the control center, as well as between the smart meter and customer loads would be facilitated for demand response, dynamic

  6. SMART METER PRIVACY USING A RECHARGEABLE BATTERY: MINIMIZING THE RATE OF INFORMATION LEAKAGE

    E-Print Network [OSTI]

    Khisti, Ashish

    SMART METER PRIVACY USING A RECHARGEABLE BATTERY: MINIMIZING THE RATE OF INFORMATION LEAKAGE David. INTRODUCTION Deployments of smart electricity meters to residential homes con- tinue unabated around the world resources. Smart meters are essential to coordinate the desired charging and discharg- ing of the batteries

  7. Designing Privacy-preserving Smart Meters with Low-cost Microcontrollers

    E-Print Network [OSTI]

    Shenoy, Prashant

    Designing Privacy-preserving Smart Meters with Low-cost Microcontrollers Andres Molina Microsoft Research Cambridge Abstract. Smart meters that track fine-grained electricity usage and implement smart meter deployment is that fine-grained usage data indirectly reveals detailed information about

  8. Tracking States of Massive Electrical Appliances by Lightweight Metering and Sequence Decoding

    E-Print Network [OSTI]

    Wang, Yongcai

    to track the on/off states of N appliances by deploying only m smart meters on the power load tree, where m demonstrate some interesting structures of the problem. Keywords Energy auditing, Smart meter, Deployment smart meter networks, and thus suffer from the high deploy- ment, maintenance and data collection costs

  9. Too expensive to meter: The influence of transaction costs in transportation and

    E-Print Network [OSTI]

    Odlyzko, Andrew M.

    in the electricity sector. Just the opposite appears to be happening. ``Smart meters'' that charge di#erent pricesToo expensive to meter: The influence of transaction costs in transportation and communication to meter, ... It is not too much to expect that our children will know of great periodic regional famines

  10. Infants Prefer the Musical Meter of Their Own Culture: A Cross-Cultural Comparison

    E-Print Network [OSTI]

    Ahmad, Sajjad

    , American infants preferred Western over Balkan meter, whereas Turkish infants, who were familiar with both Western and Balkan meters, exhibited no preference. Experiments 2 and 3 presented infants with either a Western or Balkan meter paired with an arbitrary rhythm with complex ratios not common to any musical

  11. Metering Plan: Monitoring Energy and Potable Water Use in PNNL EMS4 Buildings

    SciTech Connect (OSTI)

    Pope, Jason E.

    2012-07-25T23:59:59.000Z

    This Plan presents progress toward the metering goals shared by all national laboratories and discusses PNNL's contemporary approach to the installation of new meters. In addition, the Plan discusses the data analysis techniques with which PNNL is working to mature using endless data streams made available as a result of increased meter deployment.

  12. Compressed Meter Reading for Delay-sensitive and Secure Load Report in Smart Grid

    E-Print Network [OSTI]

    Qiu, Robert Caiming

    of smart meters, which collects the current load of smart meters installed at each home and then forwards1 Compressed Meter Reading for Delay-sensitive and Secure Load Report in Smart Grid Husheng Li, Rukun Mao, Lifeng Lai and Robert. C. Qiu Abstract-- It is a key task in smart grid to send the readings

  13. HP replacement program increases efficiency, protection

    SciTech Connect (OSTI)

    NONE

    1997-10-01T23:59:59.000Z

    For more than 50 years, compression equipment along the 2,000-mile Tennessee Gas Pipeline has been helping to supply natural gas needs for the Northeast. But increasing demand and a need for more environmentally safe equipment mean a major replacement program for the compressor stations that make the natural gas transmission possible. Today it is one of the longest gas pipelines in the world, carrying more than 1 Bcf/d of natural gas. New compression equipment is being installed to boost efficiency and meet more stringent environmental standards. In 1993, Tenneco Energy, purchased by El Paso Energy in December 1996, initiated a Horsepower Replacement Program intended to replace older, inefficient technology with more advanced equipment. A major objective was to improve operational effectiveness and to reduce harmful nitrogen oxide and carbon monoxide emissions by converting much of the machinery to electric-driven compression equipment.

  14. Valve assembly having remotely replaceable bearings

    DOE Patents [OSTI]

    Johnson, Evan R. (San Diego, CA); Tanner, David E. (Poway, CA)

    1980-01-01T23:59:59.000Z

    A valve assembly having remotely replaceable bearings is disclosed wherein a valve disc is supported within a flow duct for rotation about a pair of axially aligned bearings, one of which is carried by a spindle received within a diametral bore in the valve disc, and the other of which is carried by a bearing support block releasably mounted on the duct circumferentially of an annular collar on the valve disc coaxial with its diametrical bore. The spindle and bearing support block are adapted for remote removal to facilitate servicing or replacement of the valve disc support bearings.

  15. Fluidized bed boiler convective zone tube replacement

    SciTech Connect (OSTI)

    Not Available

    1991-03-21T23:59:59.000Z

    A major problem with the Georgetown University Atomspheric-Pressure, Fluidized-Bed Combustor-Boiler (GU AFBC) experienced during the first six years of operation was tube erosion. Previous corrective measures for in-bed tube erosion appeared to be effective, but excessive wear of the convective zone tubes was still occurring, and the entire heat transfer tube bundle in the boiler required replacement. In the planned project,the eroded tubes would be replaced, and the convective zone modified to eliminate the problem. Progress is discussed.

  16. Expenses Revenues

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Expense: 1 Reclamation 44,585,384 Western 59,400,596 Total O&M Expense 103,985,980 Purchase Power Expense: Custom Product and Supplemental Power 2 209,685,496 209,685,496...

  17. abdominal ct replace: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    target module was accomplished using only remote handling tooling and procedures (hands meter of high density concrete The Target Service Bay is designed for full remote...

  18. aortic root replacement: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    target module was accomplished using only remote handling tooling and procedures (hands meter of high density concrete The Target Service Bay is designed for full remote...

  19. Reversing Wolbachia-based population replacement

    E-Print Network [OSTI]

    Dobson, Stephen L.

    Wolbachia bacteria as a vehicle for population replace- ment. Also discussed are strategies strategies and provide mechan- isms for the autonomous spread of desired transgenes into the targeted relative to the natural population [15­17]. Primary candidates for gene-drive strategies are autonomous

  20. Measure Guideline: Window Repair, Rehabilitation, and Replacement

    SciTech Connect (OSTI)

    Baker, P.

    2012-12-01T23:59:59.000Z

    This measure guideline provides information and guidance on rehabilitating, retrofitting, and replacing existing window assemblies in residential construction. The intent is to provide information regarding means and methods to improve the energy and comfort performance of existing wood window assemblies in a way that takes into consideration component durability, in-service operation, and long term performance of the strategies.

  1. Testing the 2-element 4-wire delta watthour meter

    E-Print Network [OSTI]

    Grasshoff, Lynn Howard

    1950-01-01T23:59:59.000Z

    by interaction of the fluxes and disk eddy currents of the various elements. Since the 2. Ihrtin, Z. S. , Some Features of Present Day Polyphass 1+ters, p. 7 elements had to be plaoed at vaz ious locations around the periphery of the disk, spaoe displacement... of the meter which is inversely pro- portional to the load, Potential-current or current?potentis1 interference is the reaction caused by interaction of the flux of any potential or current electromagnet and the disk eddy currents induced respectively...

  2. Testing the 2-element 4-wire delta watthour meter 

    E-Print Network [OSTI]

    Grasshoff, Lynn Howard

    1950-01-01T23:59:59.000Z

    & and other material& and for affording valuable suggestions for the prepaxation of this thesis. Appreciation is also exnxressed to M! . R. H. Mighell and Mr. H. E. Trekell of the General Electric Company fax supplying a ~ire delta meter and various... four wire delta system is used to supply polyphase and single phase loads from a bank of delta-oonneeted transformers. The squit is illustrated in Pigure L, Polyphase loads are supplied in the usual manner from the three lines a b-o, and single phase...

  3. The Coldest Cubic Meter in the Known Universe

    E-Print Network [OSTI]

    Ouellet, Jonathan

    2014-01-01T23:59:59.000Z

    CUORE is a 741 kg array of TeO2 bolometers that will search for the neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso in Italy, where it will begin taking data in 2015. The CUORE cryostat will cool several metric tonnes of material to below 1 K and the CUORE detector itself will operate at a typical temperature of 10 mK. At this temperature, the CUORE detector will be the coldest contiguous cubic meter in the known Universe.

  4. ESB Smart Meter Projects (Smart Grid Project) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A Potential MicrohydroDistrict ofDongjinDynetek42EOPEPODESB Smart Meter

  5. Smart Meters and a Smarter Grid | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMayDepartment of Energy Ready,Smart Grid RFIGrid: Enabler ofSmart Meters

  6. BPA Metering Services Editing and Estimating Procedures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office511041cloth DocumentationProductsAlternativeOperationalAugustDecade Later: AreAugust 19, 2009 InMetering

  7. Smart Meter Investments Support Rural Economy in Arkansas

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn April 23, 2014,Zaleski - PolicyWork Force withNonprofit---5---12DOESmarttheSmart Meter

  8. Revenue from Retail Sales of Electricity (Thousand Dollars) by State by Provider

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocks Nov-14 Dec-14Table 4.April 25, 20137a.06Retail Sales ofRevenue

  9. THE GROWTH OF LIMITS OF VERTEX REPLACEMENT RULES

    E-Print Network [OSTI]

    Previte, Joseph P.

    THE GROWTH OF LIMITS OF VERTEX REPLACEMENT RULES JOSEPH PREVITE, MICHELLE PREVITE, AND MARY a vertex replacement rule given by exactly one replacement graph generates an infinite graph for the growth degree of infinite graphs with polynomial growth that are gener- ated by vertex replacement rules

  10. Orthopaedic Surgery Center of Joint Preservation and Replacement

    E-Print Network [OSTI]

    Oliver, Douglas L.

    Orthopaedic Surgery Center of Joint Preservation and Replacement After Total Hip Replacement new hip! You are going home after a successful total hip replacement. Although there is still much. The benefits of a total hip replacement are great, but they do take a while to be realized. Hip Precautions

  11. Orthopaedic Surgery Center of Joint Preservation and Replacement

    E-Print Network [OSTI]

    Oliver, Douglas L.

    Orthopaedic Surgery Center of Joint Preservation and Replacement After Total Knee Replacement are going home after a successful total knee replacement. Although there is still much work to do, we have replacement are great, but they do take a while to be realized. We have put together some helpful hints

  12. California Solar Initiative (CSI) Thermal Program Metering Installation Guide Purpose: The purpose of this metering installation guide is to provide participating eligible contractors

    E-Print Network [OSTI]

    1 California Solar Initiative (CSI) Thermal Program Metering Installation Guide Purpose and monitoring purposes: Customer Performance Monitoring (CPM), Opt-in Measurement and Evaluation (M&E) and 70 with interpreting the following schematics. 1. Customer Performance Monitoring (CPM) For CPM, metering either

  13. Collector main replacement at Indianapolis Coke

    SciTech Connect (OSTI)

    Sickle, R.R. Van

    1997-12-31T23:59:59.000Z

    Indianapolis Coke is a merchant coke producer, supplying both foundry and blast furnace coke to the industry. The facility has three coke batteries: two 3 meter batteries, one Wilputte four divided and one Koppers Becker. Both batteries are underjet batteries and are producing 100% foundry coke at a net coking time of 30.6 hours. This paper deals with the No. 1 coke battery, which is a 72 oven, gun fired, 5 meter Still battery. No. 1 battery produces both foundry and blast furnace coke at a net coking rate of 25.4 hours. No. 1 battery was commissioned in 1979. The battery is equipped with a double collector main. Although many renovations have been completed to the battery, oven machinery and heating system, to date no major construction projects have taken place. Deterioration of the collector main was caused in part from elevated levels of chlorides in the flushing liquor, and temperature fluctuations within the collector main. The repair procedures are discussed.

  14. Meter scale plasma source for plasma wakefield experiments

    SciTech Connect (OSTI)

    Vafaei-Najafabadi, N.; Shaw, J. L.; Marsh, K. A.; Joshi, C.; Hogan, M. J. [Department of Electrical Engineering, University of California Los Angeles, Los Angeles, CA 90095 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

    2012-12-21T23:59:59.000Z

    High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, head erosion will be a significant challenge for the planned experiments. In this work we report on our design of a meter scale plasma source for these experiments to effectively avoid the problem of head erosion. The plasma source is based on a homogeneous metal vapor gas column that is generated in a heat pipe oven [2]. A lithium oven over 30 cm long at densities over 10{sup 17} cm{sup -3} has been constructed and tested at UCLA. The plasma is then generated by coupling a 10 TW short pulse Ti:Sapphire laser into the gas column using an axicon lens setup. The Bessel profile of the axicon setup creates a region of high intensity that can stretch over the full length of the gas column with approximately constant diameter. In this region of high intensity, the alkali metal vapor is ionized through multi-photon ionization process. In this manner, a fully ionized meter scale plasma of uniform density can be formed. Methods for controlling the plasma diameter and length will also be discussed.

  15. The magnetic flywheel flow meter: Theoretical and experimental contributions

    SciTech Connect (OSTI)

    Buchenau, D., E-mail: d.buchenau@hzdr.de; Galindo, V.; Eckert, S. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Bautzner Landstraße 400, 01328 Dresden (Germany)

    2014-06-02T23:59:59.000Z

    The development of contactless flow meters is an important issue for monitoring and controlling of processes in different application fields, like metallurgy, liquid metal casting, or cooling systems for nuclear reactors and transmutation machines. Shercliff described in his book “The Theory of Electromagnetic Flow Measurement, Cambridge University Press, 1962” a simple and robust device for contact-less measurements of liquid metal flow rates which is known as magnetic flywheel. The sensor consists of several permanent magnets attached on a rotatable soft iron plate. This arrangement will be placed closely to the liquid metal flow to be measured, so that the field of the permanent magnets penetrates into the fluid volume. The flywheel will be accelerated by a Lorentz force arising from the interaction between the magnetic field and the moving liquid. Steady rotation rates of the flywheel can be taken as a measure for the mean flow rate inside the fluid channel. The present paper provides a detailed theoretical description of the sensor in order to gain a better insight into the functional principle of the magnetic flywheel. Theoretical predictions are confirmed by corresponding laboratory experiments. For that purpose, a laboratory model of such a flow meter was built and tested on a GaInSn-loop under various test conditions.

  16. Developing Business Case for Electrical System Replacement

    E-Print Network [OSTI]

    Miller, Carles

    2006-05-19T23:59:59.000Z

    and distribution equipment. This paper is a great resource for technical information concerning failure rates of electrical system protective relaying. ?Upgrading and Enhancing the Generator Protection System by Making Use of Digital Systems?, published.... This paper focus on upgrading generation plant electrical systems and is a good reference for performing generator relay protection upgrades. Chapter 2 ? Literature Review Page 7 of 47 Developing Business Case For Electrical System Replacement Projects...

  17. Flow boiling test of GDP replacement coolants

    SciTech Connect (OSTI)

    Park, S.H. [comp.

    1995-08-01T23:59:59.000Z

    The tests were part of the CFC replacement program to identify and test alternate coolants to replace CFC-114 being used in the uranium enrichment plants at Paducah and Portsmouth. The coolants tested, C{sub 4}F{sub 10} and C{sub 4}F{sub 8}, were selected based on their compatibility with the uranium hexafluoride process gas and how well the boiling temperature and vapor pressure matched that of CFC-114. However, the heat of vaporization of both coolants is lower than that of CFC-114 requiring larger coolant mass flow than CFC-114 to remove the same amount of heat. The vapor pressure of these coolants is higher than CFC-114 within the cascade operational range, and each coolant can be used as a replacement coolant with some limitation at 3,300 hp operation. The results of the CFC-114/C{sub 4}F{sub 10} mixture tests show boiling heat transfer coefficient degraded to a minimum value with about 25% C{sub 4}F{sub 10} weight mixture in CFC-114 and the degree of degradation is about 20% from that of CFC-114 boiling heat transfer coefficient. This report consists of the final reports from Cudo Technologies, Ltd.

  18. 2008 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Smart Meters, Rates and the Customer

    E-Print Network [OSTI]

    © 2008 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Smart Meters, OR #12;2 SDG&E Smart Meter Goals · Install AMI/smart metering for all SDG&E electric and gas business're starting to recreate our relationship with customers and transform our company #12;Smart Meter Business

  19. Photoelastic stress analysis on a Phoenix 7. 9-meter blade

    SciTech Connect (OSTI)

    Musial, W.D.; Jenks, M.D.; Osgood, R.M.; Johnson, J.A.

    1991-10-01T23:59:59.000Z

    Photoelastic tests were conducted on the Phoenix 7.9-meter blade to develop the basic methodology for locating critical strain areas on full-scale composite structures. Under relatively low elastic loading the strain fields over various regions on the blade planform were documented with 35mm photographs under different loading conditions at the Solar Energy Research Institute (SERI) Structural Test Facility (STF). Strain concentrations were easily located and quantified. Principal strain magnitudes and directions were determined at the highest strain areas using separator gages. Results were compared to measured operating loads. This experiment demonstrated the value of experimental stress analysis using the photoelastic technique for the evaluation of composite blade designs. 9 refs., 6 figs., 3 tabs.

  20. Plutonium detection with a new fission neutron survey meter

    SciTech Connect (OSTI)

    Klett, A. [EG and G Berthold, Bad Wildbad (Germany)] [EG and G Berthold, Bad Wildbad (Germany)

    1999-08-01T23:59:59.000Z

    The search for illicit trafficking or hidden plutonium sources has become a pressing issue, especially since the breakdown of the former Soviet Union. Plutonium is extremely dangerous and hard to detect over large distances. The {alpha}-particles and X-rays which are emitted by plutonium isotopes can easily be shielded by the material itself or by surroundings. Besides a few {gamma}`s, the only penetrating radiation emitted by plutonium samples are neutrons from spontaneous fission. Therefore a special neutron survey meter with unrivaled sensitivity for fission neutrons has been newly designed. The hand-held, commercially available instrument has an approximate weight of 4 kg and is battery driven. The neutron probe consists of a {sup 3}He proportional counter tube, a moderator and integrated electronics. The sensitivity is sufficient to detect plutonium masses below 100 g at a distance of 1 m within a few seconds.

  1. Prison Industries Metering at the Texas Department of Criminal Justice: Two Years of Operational Experience

    E-Print Network [OSTI]

    Bryant, J.; McBride, J.; Merka, T.

    2003-01-01T23:59:59.000Z

    PRISON INDUSTRIES METERING AT THE TEXAS DEPARTMENT OF CRIMINAL JUSTICE: TWO YEARS OF OPERATIONAL EXPERIENCE John A. Bryant John R. McBride Tom Merka Assistant Professor Chief Executive Officer Director of Utilities & Energy Texas A... in the use of energy metering to promote cost-effective prison operation. REFERENCES 1. John A. Bryant, John McBride, Tom Merka, ?State-of-the-Art Energy Sub-metering Texas Department of Criminal Justice Industries,? Proceedings of the 1st...

  2. An analysis of an application of radioactive ionization for gas flow metering

    E-Print Network [OSTI]

    Lam, Carroll Frank

    1959-01-01T23:59:59.000Z

    OF FIGURES CHAP TER I. INTRODUCTION II. EXPERIMENTAL PROCEDURE III. MEASUREMENT OF MARK I CHARACTERISTICS IV. MEASUREMENT OF MARK II CHARACTERISTICS -3 V. CONCLUSIONS . 17 35 BIBLIOGRAPHY . 37 LIST OF FIGURES FIGURE PAGE 1. A Diagram of Rutherford...'s Apparatus Z. An Ezperimental Flow Meter . 3. Mark I Meter and Test Equipment 4. Electrical Circuit 5. Current vs. Flow Rate Curve for Mark I Meter. . . . . . . . . . . . . 6. Current vs. Flow Rate for DifferentSource Spacings. . . . . . . . . . 7...

  3. automatic gas meter-reading: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Last Page Topic Index 1 Neighborhood Watch: Security and Privacy Analysis of Automatic Meter Reading Systems Engineering Websites Summary: in transforming the current electrical...

  4. Uncertainty Analysis for a Virtual Flow Meter Using an Air-Handling Unit Chilled Water Valve

    SciTech Connect (OSTI)

    Song, Li; Wang, Gang; Brambley, Michael R.

    2013-04-28T23:59:59.000Z

    A virtual water flow meter is developed that uses the chilled water control valve on an air-handling unit as a measurement device. The flow rate of water through the valve is calculated using the differential pressure across the valve and its associated coil, the valve command, and an empirically determined valve characteristic curve. Thus, the probability of error in the measurements is significantly greater than for conventionally manufactured flow meters. In this paper, mathematical models are developed and used to conduct uncertainty analysis for the virtual flow meter, and the results from the virtual meter are compared to measurements made with an ultrasonic flow meter. Theoretical uncertainty analysis shows that the total uncertainty in flow rates from the virtual flow meter is 1.46% with 95% confidence; comparison of virtual flow meter results with measurements from an ultrasonic flow meter yielded anuncertainty of 1.46% with 99% confidence. The comparable results from the theoretical uncertainty analysis and empirical comparison with the ultrasonic flow meter corroborate each other, and tend to validate the approach to computationally estimating uncertainty for virtual sensors introduced in this study.

  5. Now that we have smart meters, what do we do with them?

    SciTech Connect (OSTI)

    NONE

    2010-01-15T23:59:59.000Z

    For years, electric utilities have been dreaming about the day when they would have smart meters on customers' premises. However, there have always been lingering doubts among some consumer advocates and critics of the smart metering schemes about their cost-effectiveness. An issue that is beginning to become noticed is that installing smart meters and introducing variable pricing will accomplish very little unless the price signals are communicated to consumers and -- more important -- to energy-using devices beyond the meter. Since consumers are unlikely to sit around watching variable prices and adjusting consumption or thermostat settings, ways must be found for the price signals to automatically and directly communicate with devices,.

  6. Microsoft Word - Ross-Lexington No1 Meter project-CX .doc

    Broader source: Energy.gov (indexed) [DOE]

    Power Administration (BPA) proposes to install meters under the Ross-Lexington No. 1 transmission line, between towers 15 and 16, to better understand and predict line sag....

  7. adaptive dynamic replacement: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    1 Who Replaces Whom? Local versus Non-local Replacement in Social and Evolutionary Dynamics CERN Preprints Summary: In this paper, we inspect well-known population genetics and...

  8. Magnesium Replacement of Aluminum Cast Components in a Production...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Replacement of Aluminum Cast Components in a Production V6 Engine to Effect Cost-Effective Mass Reduction Magnesium Replacement of Aluminum Cast Components in a Production V6...

  9. Replacing PG and E's Milpitas terminal

    SciTech Connect (OSTI)

    Rawcliffe, R.S.; Maceyka, R.A. (Pacific Gas and Electric Co., San Francisco, CA (US))

    1991-07-01T23:59:59.000Z

    This paper reports that Pacific Gas and Electric Co.'s Milpitas Terminal was originally built in 1929, when natural gas was first brought to the San Francisco Bay Area from the Kettleman Hills gas fields. This paper reports that in 1985, a project was begun to replace the old terminal due to maintenance problems, odor complaints and unaccounted-for gas due to poor measurement quality. The location of the terminal was also a problem. A proposed highway expansion would encroach into the yard area where the existing pipeline was located. In addition, the original location was in agricultural lands, which was changing to commercial use.

  10. Replacing an Oversized and Underloaded Electric Motor

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy using Fues Cells Webinar, July0 Replace2-AIncandescent1

  11. Text-Alternative Version: LED Replacements for Linear Fluorescent Lamps

    Broader source: Energy.gov [DOE]

    Below is the text-alternative version of the "LED Replacements for Linear Fluorescent Lamps" webcast, held June 20, 2011.

  12. Revenue Maximization of Electricity Generation for a Wind Turbine Integrated with a Compressed Air Energy Storage System

    E-Print Network [OSTI]

    Li, Perry Y.

    Energy Storage System Mohsen Saadat, Farzad A. Shirazi, Perry Y. Li Abstract-- A high-level supervisory controller is developed for a Compressed Air Energy Storage (CAES) system integrated with a wind turbine the effect of storage system sizing on the maximum revenue. I. INTRODUCTION Large-scale cost effective energy

  13. Computer Replacement Guidelines Environmental Health and Safety, Stanford University

    E-Print Network [OSTI]

    Computer Replacement Guidelines Environmental Health and Safety, Stanford University 17 November 2005 This document describes the guidelines for replacing laptop and desktop computers at Environmental Health and Safety. PC laptop and desktop computers will be replaced a) on an ongoing basis where

  14. Inference of Edge Replacement Graph Grammars Jacek P. Kukluk1

    E-Print Network [OSTI]

    Holder, Lawrence B.

    Inference of Edge Replacement Graph Grammars Jacek P. Kukluk1 , Lawrence B. Holder2 , and Diane J@eecs.wsu.edu Abstract We describe an algorithm and experiments for inference of edge replacement graph grammars for inference of Node Replacement Recursive Graph Grammars [7]. In this paper we describe an approach

  15. FUNCTIONAL ESTIMATION FOR A MULTICOMPONENT AGE REPLACEMENT MODEL

    E-Print Network [OSTI]

    L'Ecuyer, Pierre

    1 FUNCTIONAL ESTIMATION FOR A MULTICOMPONENT AGE REPLACEMENT MODEL Pierre L'Ecuyer, Benoit Martin, controlled by a replacement rule based on age thresholds. We show how to estimate the expected cost­ generative simulation, maintenance models, age replacement policies. #12; 2 L'ECUYER, MARTIN, AND V ' AZQUEZ

  16. 1 INTRODUCTION The replacement investment decision is clearly a

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    1 INTRODUCTION The replacement investment decision is clearly a strategic objective of a company for the replacement decision largely depends on the company context. However, we can summarize the motivations leading over time and prove that the replacement policy at equal intervals is optimum. However, the linear

  17. Application for Amendment 80 Vessel Replacement Page 1 of 6

    E-Print Network [OSTI]

    Application for Amendment 80 Vessel Replacement Page 1 of 6 Revised: 12/23/2013 OMB Control No. 0648-0565 Expiration Date: 01/31/2016 APPLICATION FOR AMENDMENT 80 VESSEL REPLACEMENT United States OF THE AMENDMENT 80 VESSEL BEING REPLACED 1. Vessel Name: 2. ADF&G Vessel Registration No.: 3. USCG Documentation

  18. Page Replacement and Reference Bit Emulation in Mach

    E-Print Network [OSTI]

    Page Replacement and Reference Bit Emulation in Mach Richard P. Draves rpd@cs.cmu.edu School of Computer Science Carnegie Mellon University 5000 Forbes Avenue Pittsburgh, PA 15213 Abstract A page­replacement in software. This paper describes the Mach kernel's page­replacement algorithm and considers three software

  19. The Cosmic Origins Spectrograph: A Hubble Replacement Instrument

    E-Print Network [OSTI]

    Colorado at Boulder, University of

    The Cosmic Origins Spectrograph: A Hubble Replacement Instrument for the 2002 Reservicing Mission Origins Spectrograph (COS) has recently been selected as a replacement instrument for the Hubble Space Telescope. Installation is scheduled for late 2002, replacing COSTAR, which at that time will be unnecessary

  20. Diploma Replacement Request FOR REGISTRAR'S OFFICE USE ONLY

    E-Print Network [OSTI]

    Feschotte, Cedric

    Diploma Replacement Request FOR REGISTRAR'S OFFICE USE ONLY Updated: 08/26/09 Use this form to request a replacement or additional diploma. · The name on your diploma must be the same the Registrar's Office, Registration and Records Division prior to requesting your replacement diploma

  1. Cache Replacement Policy Using Map-based Adaptive Insertion

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Cache Replacement Policy Using Map-based Adaptive Insertion Yasuo Ishii The University of Tokyo insertion policy (MAIP) for a novel cache replacement. The MAIP estimates the data reuse possibility policy. 1. INTRODUCTION The cache replacement policy plays an important role in improving system

  2. University of Utah Payroll Department Stop Payment -Replacement Form

    E-Print Network [OSTI]

    Provancher, William

    University of Utah Payroll Department Stop Payment - Replacement Form Affidavit to request replacement of a lost, stolen, or damaged, payroll check. Please note that it takes 5 to 7 days to process is given to induce a replacement check for one originally issued. 3. I agree to indemnify and hold

  3. FUNCTIONAL ESTIMATION FOR A MULTICOMPONENT AGE REPLACEMENT MODEL

    E-Print Network [OSTI]

    Vázquez-Abad, Felisa J.

    FUNCTIONAL ESTIMATION FOR A MULTICOMPONENT AGE REPLACEMENT MODEL Pierre L'Ecuyer, Benoit Martin, controlled by a replacement rule based on age thresholds. We show how to estimate the expected cost­ generative simulation, maintenance models, age replacement policies. #12; L'ECUYER, MARTIN, AND V ' AZQUEZ

  4. Node discovery and replacement using mobile Kalypso Magklara1

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Node discovery and replacement using mobile robot Kalypso Magklara1 , Dimitrios Zorbas1 and Tahiry, that discovers the nodes around it and replaces the active nodes, whose energy is drained, by fully charged and that decide, which nodes to replace. We simulate our algorithms and our findings show that all nodes that fail

  5. REPLACEMENT DIPLOMA ORDER FORM BOISE STATE REGISTRAR'S OFFICE

    E-Print Network [OSTI]

    Barrash, Warren

    REPLACEMENT DIPLOMA ORDER FORM BOISE STATE REGISTRAR'S OFFICE Administration Building, Room 110-3169 The replacement diploma will bear the signatures of the current University President and Registrar and have the words Replacement Diploma printed under the university seal. Allow 3-4 weeks for delivery. You

  6. Trinity College Green Week 2012 Energy Competition Win a Domestic Energy Meter

    E-Print Network [OSTI]

    O'Mahony, Donal E.

    Trinity College Green Week 2012 Energy Competition ­ Win a Domestic Energy Meter As part of College Green Week the "e3" programme and Director of Buildings Office is promoting an energy related would you like to win a domestic whole house energy meter as part of Trinity College Green Week 2012

  7. A Scalable Soft Spot Analysis Methodology for Compound Noise Effects in Nano-meter Circuits

    E-Print Network [OSTI]

    California at San Diego, University of

    A Scalable Soft Spot Analysis Methodology for Compound Noise Effects in Nano-meter Circuits Chong methodology to study the vulnerability of digital ICs exposed to nano-meter noise and transient soft errors. First, we define "softness" as an important characteristic to gauge system vulnerability. Then several

  8. Energy-Harvesting Thermoelectric Sensing for Unobtrusive Water and Appliance Metering

    E-Print Network [OSTI]

    Dutta, Prabal

    Energy-Harvesting Thermoelectric Sensing for Unobtrusive Water and Appliance Metering Bradford that meters using the same thermoelectric generator with which it powers itself. In short, the rate at which be harvested with a thermoelectric generator (TEG) to power a sensor node. TEGs utilize the Seebeck effect

  9. Unaccounted-for gas project. Measurement Task Force (orifice meter studies). Volume 2B. Final report

    SciTech Connect (OSTI)

    Godkin, B.J.; Robertson, J.D.; Wlasenko, R.G.; Cowgill, R.M.; Grinstead, J.R.

    1990-06-01T23:59:59.000Z

    The study was aimed at determining unaccounted-for (UAF) gas volumes resulting from operating Pacific Gas and Electric Co.'s transmission and distribution systems during 1987. Activities and methods are described and results are presented for research conducted on orifice meter accuracy. The Measurement Task Force determined that orifice metering inaccuracies were the largest single contributor to 1987 UAF.

  10. A Technology for Electronic Energy Meters Intelligent Accounting Using Distributed Database over TCP/IP Network

    E-Print Network [OSTI]

    Borissova, Daniela

    4 8 A Technology for Electronic Energy Meters Intelligent Accounting Using Distributed Database in their entirety. 2. Electronic energy metersaccountingtechnology developed inthe project The technology under Collection Electronic Energy Meters Distributed Database over TCP/IP Network Optical Head Optical Port RS-232

  11. MODEL-DRIVEN ANALYTICS OF ENERGY METER DATA IN SMART HOMES

    E-Print Network [OSTI]

    Shenoy, Prashant

    MODEL-DRIVEN ANALYTICS OF ENERGY METER DATA IN SMART HOMES A Dissertation Presented by SEAN BARKER administrative tasks, to Tyler Trafford for frequent technical support, and to my past and present labmates Barker 2014 All Rights Reserved #12;MODEL-DRIVEN ANALYTICS OF ENERGY METER DATA IN SMART HOMES

  12. On Required Distances to Absorb Metering Delays C. Gwiggner, S. Nagaoka

    E-Print Network [OSTI]

    Gwiggner, Claus Peter

    On Required Distances to Absorb Metering Delays C. Gwiggner, S. Nagaoka Electronic Navigation Research Institute Chofu, Tokyo Abstract We analyze the distance that is required to absorb metering delays are a common phenomenon [1]. The reason is that uncertainty factors, including competition for punctual

  13. Energy Metering for Free: Augmenting Switching Regulators for Real-Time Monitoring

    E-Print Network [OSTI]

    Energy Metering for Free: Augmenting Switching Regulators for Real-Time Monitoring Prabal Dutta of Technology Berkeley, CA 94720 Cambridge, MA 02139 Abstract We present iCount, a new energy meter design. For many systems that have a built-in switching regulator, adding a single wire between the regulator

  14. Power Line Carrier (PLC) Signal Analysis of Smart Meters for Outlier Detection

    E-Print Network [OSTI]

    Akella, Srinivas

    Power Line Carrier (PLC) Signal Analysis of Smart Meters for Outlier Detection Rakesh Rao Dept-- A method for identifying outliers among a set of smart meters by using the power line carrier (PLC) signal strength is presented in this paper. The broad goal is to use the PLC signal as a predictor of transmission

  15. Towards a Secure, Wireless-Based, Home Area Network for Metering in Smart Grids

    E-Print Network [OSTI]

    Namboodiri, Vinod

    1 Towards a Secure, Wireless-Based, Home Area Network for Metering in Smart Grids Vinod Namboodiri and the consumer. This work takes a comprehensive look at wireless security in the smart meter-based home, Student Member, IEEE, Ward Jewell, Fellow, IEEE Abstract--Compared to the conventional grid, the smart

  16. Application for Replacement JCU Award (Certificate/Testamur) -FM-EX-VApr2012 REQUEST FOR REPLACEMENT JCU AWARD

    E-Print Network [OSTI]

    Application for Replacement JCU Award (Certificate/Testamur) - FM-EX-VApr2012 REQUEST FOR REPLACEMENT JCU AWARD (CERTIFICATE/TESTAMUR) 1. PERSONAL DETAILS JCU Student Number (8 digits): Title: rDr r after the fee is paid. · Replacement Testamurs - $70 (Diploma, Bachelor, Master and Doctoral

  17. Ash level meter for a fixed-bed coal gasifier

    DOE Patents [OSTI]

    Fasching, George E. (Morgantown, WV)

    1984-01-01T23:59:59.000Z

    An ash level meter for a fixed-bed coal gasifier is provided which utilizes the known ash level temperature profile to monitor the ash bed level. A bed stirrer which travels up and down through the extent of the bed ash level is modified by installing thermocouples to measure the bed temperature as the stirrer travels through the stirring cycle. The temperature measurement signals are transmitted to an electronic signal process system by an FM/FM telemetry system. The processing system uses the temperature signals together with an analog stirrer position signal, taken from a position transducer disposed to measure the stirrer position to compute the vertical location of the ash zone upper boundary. The circuit determines the fraction of each total stirrer cycle time the stirrer-derived bed temperature is below a selected set point, multiplies this fraction by the average stirrer signal level, multiplies this result by an appropriate constant and adds another constant such that a 1 to 5 volt signal from the processor corresponds to a 0 to 30 inch span of the ash upper boundary level. Three individual counters in the processor store clock counts that are representative of: (1) the time the stirrer temperature is below the set point (500.degree. F.), (2) the time duration of the corresponding stirrer travel cycle, and (3) the corresponding average stirrer vertical position. The inputs to all three counters are disconnected during any period that the stirrer is stopped, eliminating corruption of the measurement by stirrer stoppage.

  18. Microsoft Word - CX_Memo_Whitefish.docx

    Broader source: Energy.gov (indexed) [DOE]

    FEC with equipment specifications, witness acceptance tests on revenue meter transformers prior to installation, and perform in-service revenue metering checks on voltages...

  19. 4.5 Meter high level waste canister study

    SciTech Connect (OSTI)

    Calmus, R. B.

    1997-10-01T23:59:59.000Z

    The Tank Waste Remediation System (TWRS) Storage and Disposal Project has established the Immobilized High-Level Waste (IBLW) Storage Sub-Project to provide the capability to store Phase I and II BLW products generated by private vendors. A design/construction project, Project W-464, was established under the Sub-Project to provide the Phase I capability. Project W-464 will retrofit the Hanford Site Canister Storage Building (CSB) to accommodate the Phase I I-ILW products. Project W-464 conceptual design is currently being performed to interim store 3.0 m-long BLW stainless steel canisters with a 0.61 in diameter, DOE is considering using a 4.5 in canister of the same diameter to reduce permanent disposal costs. This study was performed to assess the impact of replacing the 3.0 in canister with the 4.5 in canister. The summary cost and schedule impacts are described.

  20. Application Form for Replacement Diploma/Program Certificate (Form must be notarized)

    E-Print Network [OSTI]

    Application Form for Replacement Diploma/Program Certificate (Form must be notarized) Complete to Princeton University as follows: Replacement Diploma - $75 Replacement Program Certificate - $30 Please

  1. Electricit de France's study of the acoustic scintillation flow meter results in expanding its range and sensitivity

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    for the next generation of acoustic scintillation flow meters. 1. Background For EDF's hydraulic power division, turbine flow metering represents a high stake issue as it involves a significant amount of knowhow, work

  2. DREAM: DiffeRentially privatE smArt Metering

    E-Print Network [OSTI]

    Acs, Gergely

    2012-01-01T23:59:59.000Z

    This paper presents a new privacy-preserving smart metering system. Our scheme is private under the differential privacy model and therefore provides strong and provable guarantees. With our scheme, an (electricity) supplier can periodically collect data from smart meters and derive aggregated statistics while learning only limited information about the activities of individual households. For example, a supplier cannot tell from a user's trace when he watched TV or turned on heating. Our scheme is simple, efficient and practical. Processing cost is very limited: smart meters only have to add noise to their data and encrypt the results with an efficient stream cipher.

  3. Instrument Qualification of Custom Fabricated Water Activity Meter for Hot Cell Use

    SciTech Connect (OSTI)

    McCoskey, Jacob K.

    2014-01-22T23:59:59.000Z

    This report describes a custom fabricated water activity meter and the results of the qualification of this meter as described in the laboratory test plan LAB-PLN-11-00012, Testing and Validation of an Enhanced Acquisition and Control System. It was calibrated against several NaOH solutions of varying concentrations to quantify the accuracy and precision of the instrument at 20 °C and 60 °C. Also, a schematic and parts list of the equipment used to make the water activity meter will be presented in this report.

  4. Sub-metering to Electricity Use in Large-scale Commercial Buildings

    E-Print Network [OSTI]

    Yuan, W.

    2006-01-01T23:59:59.000Z

    ~240Hotel251218113~129Office Building181118103~119government office building4582775~89 #0;?#0;? Great Difference between each type Sub-metering and statistics to electricity use in commercial buildings 5 Situation of Energy consumption in Large...Sub-metering to Electricity Use in Large-scale Commercial Buildings Wang YuanTsinghua University2006.11 Sub-metering and statistics to electricity use in commercial buildings 2 Index #0;?#0;? Situation of Energy consumption in commercial buildings...

  5. Replacement of the Advanced Test Reactor control room

    SciTech Connect (OSTI)

    Durney, J.L.; Klingler, W.B. (EG and G Idaho, Inc., Idaho Falls, ID (USA))

    1989-01-01T23:59:59.000Z

    The control room for the Advanced Test Reactor has been replaced to provide modern equipment utilizing current standards and meeting the current human factors requirements. The control room was designed in the early 1960 era and had not been significantly upgraded since the initial installation. The replacement did not change any of the safety circuits or equipment but did result in replacement of some of the recorders that display information from the safety systems. The replacement was completed in concert with the replacement of the control room simulator which provided important feedback on the design. The design successfully incorporates computer-based systems into the display of the plant variables. This improved design provides the operator with more information in a more usable form than was provided by the original design. The replacement was successfully completed within the scheduled time thereby minimizing the down time for the reactor. 1 fig., 1 tab.

  6. Empirical study on the Korean treasury auction focusing on the revenue comparison in multiple versus single price auction

    E-Print Network [OSTI]

    Kang, Boo-Sung

    2006-04-12T23:59:59.000Z

    EMPIRICAL STUDY ON THE KOREAN TREASURY AUCTION FOCUSING ON THE REVENUE COMPARISON IN MULTIPLE VERSUS SINGLE PRICE AUCTION A Dissertation by BOO-SUNG KANG Submitted to the Office of Graduate Studies of Texas A&M... IN MULTIPLE VERSUS SINGLE PRICE AUCTION A Dissertation by BOO-SUNG KANG Submitted to Texas A&M University in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY Approved as to style and content by...

  7. Smart Meter Aggregation via Secret-Sharing George Danezis, Cdric Fournet, Markulf Kohlweiss, Santiago Zanella-Bguelin

    E-Print Network [OSTI]

    Danezis, George

    Smart Meter Aggregation via Secret-Sharing George Danezis, Cédric Fournet, Markulf Kohlweiss,fournet,markulf,santiago}@microsoft.com ABSTRACT We design and prototype protocols for processing smart- meter readings while preserving user-sharing; smart me- tering; privacy 1. INTRODUCTION Smart metering deployments have been plagued with pri- vacy

  8. Private Memoirs of a Smart Meter Andres Molina-Markham, Prashant Shenoy, Kevin Fu, Emmanuel Cecchet, and David Irwin

    E-Print Network [OSTI]

    Shenoy, Prashant

    Private Memoirs of a Smart Meter Andr´es Molina-Markham, Prashant Shenoy, Kevin Fu, Emmanuel,shenoy,kevinfu,cecchet,irwin}@cs.umass.edu Abstract Household smart meters that measure power consumption in real-time at fine granularities are the foundation of a future smart electricity grid. However, the widespread deployment of smart meters has serious

  9. The opportunistic replacement problem: analysis and case studies

    E-Print Network [OSTI]

    Torgny Almgren

    2009-01-22T23:59:59.000Z

    Jan 22, 2009 ... The opportunistic replacement problem: analysis and case studies. Torgny Almgren (Torgny.Almgren ***at*** volvo.com) Niclas Andreasson ...

  10. androgen replacement therapy: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    gains, replacement components are typically more energy efficient than older equipment. Life cycle cost analyses encourage... Massey, G. W. 2005-01-01 153 LATTICE PATHS, SAMPLING...

  11. arthroplasty replacement hip: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    gains, replacement components are typically more energy efficient than older equipment. Life cycle cost analyses encourage... Massey, G. W. 2005-01-01 144 LATTICE PATHS, SAMPLING...

  12. Heavy-Duty Natural Gas Drayage Truck Replacement Program

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heavy-Duty Natural Gas Drayage Truck Replacement Program Principal Investigator: Vicki White South Coast Air Quality Management District May 16, 2012 Project ID ARRAVT045 This...

  13. aegypti population replacement: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Juliano, Steven A. 6 2132014 Household explosion replaces population explosion as world concern -UPI.com http:www.upiasia.comScience-Technology20140211...

  14. Plutonium finishing plant safeguards and security systems replacement study

    SciTech Connect (OSTI)

    Klear, P.F.; Humphrys, K.L.

    1994-12-01T23:59:59.000Z

    This document provides the preferred alternatives for the replacement of the Safeguards and Security systems located at the Hanford Plutonium Finishing Plant.

  15. FORMATION OF REPLACEMENT DOLOMITE IN THE LATEMAR CARBONATE BUILDUP, DOLOMITES, NORTHERN ITALY: PART 1.

    E-Print Network [OSTI]

    Carmichael, Sarah

    FORMATION OF REPLACEMENT DOLOMITE IN THE LATEMAR CARBONATE BUILDUP, DOLOMITES, NORTHERN ITALY: PART F. McDONOUGH*** ABSTRACT. Replacement dolomite in the Latemar carbonate buildup, northern Italy of vertical columns (replacement of limestone breccia pipes) and sheets (replacement along fractures

  16. The challenges of improving revenue-recognition standard for multiple-element firms:evidence from the software industry (SOP 97-2)

    E-Print Network [OSTI]

    Srivastava, Anup

    2008-10-10T23:59:59.000Z

    I investigated whether implementing SOP 97-2, the revenue-recognition standard for the software industry, reduces earnings informativeness. This standard is particularly important for two reasons: First, its provisions coincide with provisions...

  17. Have You Used an Electric Meter to Measure Your Energy Use? ...

    Broader source: Energy.gov (indexed) [DOE]

    of fun to put actual numbers to the various items in your home. Have you used an electric meter to measure your energy use? Tell us about your experience. Each Thursday, you have...

  18. Proposed Metering and Instrumentation Monitoring and Analysis Plan and Budget: Alamo Community College District 

    E-Print Network [OSTI]

    O'Neal, D. L.; Carlson, K. A.; Sweeney, J., Jr.; Milligan, K.

    2002-01-01T23:59:59.000Z

    The purpose of this overview is to outline the metering points that will be monitored by the Energy Systems Laboratory (ESL). At three of the campuses, Alamo Community College District (ACCD) has a central energy management system (EMS) installed...

  19. High Resolution Study of Micro-Meter Particle Detachment and Resuspension on Different Surfaces

    E-Print Network [OSTI]

    Kassab, Asmaa 1983-

    2012-08-16T23:59:59.000Z

    In an effort to understand the resuspension phenomena, interactions of spherical micro-meter particles (glass beads (GB) and Stainless steel (SS)) were investigated experimentally on different surfaces (glass, ceramic, hardwood, metal and chemical...

  20. 1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. HIGH-ACCURACY LASER POWER AND ENERGY METER CALIBRATION SYSTEM . . . . . . . . 2

    E-Print Network [OSTI]

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. HIGH-ACCURACY LASER POWER AND ENERGY METER CALIBRATION SYSTEM . . . . . . . . 2 2.1 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3.1 High-Accuracy Calibration System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 3.2.1 Basic cryogenic radiometer operating principal

  1. The Economic Value of PV and Net Metering to Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim

    2010-01-01T23:59:59.000Z

    a Substantial Benefit of Solar PV”, The Electricity Journal,2008. MRW & Associates. “Solar PV and Retail Rate Design”,The Economic Value of PV and Net Metering to Residential

  2. Cryotank Work Work on the 5.5 meter composite cryotank is well under

    E-Print Network [OSTI]

    at The Boeing Company in Seattle, WA. The 5.5 meter tank will be the largest automated fiber placement, out Highlights May 2013 The 5.5 m tank undergoes Automated Fiber Placement at Boeing. These flute segments

  3. Use of Rapid Temperature Measurements at a 2-Meter Depth to Augment...

    Open Energy Info (EERE)

    Temperature Gradient Drilling Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Use of Rapid Temperature Measurements at a 2-Meter Depth to...

  4. Proposed Metering and Instrumentation Monitoring and Analysis Plan and Budget: Alamo Community College District

    E-Print Network [OSTI]

    O'Neal, D. L.; Carlson, K. A.; Sweeney, J., Jr.; Milligan, K.

    2002-01-01T23:59:59.000Z

    The purpose of this overview is to outline the metering points that will be monitored by the Energy Systems Laboratory (ESL). At three of the campuses, Alamo Community College District (ACCD) has a central energy management system (EMS) installed...

  5. Smart-Metering for Monitoring Building Power Distribution Network using Instantaneous Phasor Computations of Electrical Signals

    E-Print Network [OSTI]

    K.R., Krishnanand

    2013-01-01T23:59:59.000Z

    Man, H. and L. Jae-Hyun, Smart home energy management systemand implementation of smart home energy management systemsSocial network of smart-metered homes and SMEs for grid-

  6. Flow Metering and Oxygen Trim Control Reduce Dairy Steam Plant Fuel Costs

    E-Print Network [OSTI]

    Foster, E. L.; Nelson, R. L.

    FLOW METERING AND OXYGEN TRIM CONTROL REDUCE DAIRY STEAM PLANT FUEL COSTS Edward L. Foster, Plant Engineer, Dairy Farm Products, Orrville Ohio Robert L. Nelson, Manager Engineering, Westinghouse Combustion Control DiVision, Orrville, Ohio... boiler loads. A Westinghouse Hagan Ring' Balance integrating flow meter was selected for natural gas flow measurement and Westinghouse Veritrak differential pressure transmitters with remote round chart recorders were selected for steam flow...

  7. Design of an electronic phase angle meter for use with electronic analog computers

    E-Print Network [OSTI]

    Cunningham, Allen Baxter

    1957-01-01T23:59:59.000Z

    DESIGN OF AN ELECTRONIC PHASE ANGLE METER FOR USE WITH ELECTRONIC ANALOG COMPUTERS A Thesis By Allen Baxter Cunningham Submitted to the Graduate School of the Agricultural and Mechanical College of Texas in partial fulfillment... of the requirements for the degree of MASTFR OF SCIFNCE August 1957 Ma]or Sub]ect! Electrical Engineering DESIGN OF AN ELECTRONIC PHASE ANGLE METER FOR USE WITH ELECTRONIC ANALOG COMPUTERS A Thesis Allen Baxter Cunningham Approved e to style and conte...

  8. Evaluating Government's Policies on Promoting Smart Metering in Retail Electricity Markets via Agent Based Simulation

    E-Print Network [OSTI]

    Zhang, Tao; Nuttall, William J

    to the potential energy savings, final customers for electricity, natural gas…are provided with competitively priced individual meters that accurately reflect the final customer’s actual energy consumption and that provide information on actual time of use” [13... in the UK energy market. Lessons from international experience (e.g. Italy, Sweden and California) suggest that introducing smart metering in the context of monopoly provision can be a very successful strategy. However, the characteristics of competition...

  9. 105Lunar Crater Frequency Distributions This image of the 800-meter x 480-meter region near the Apollo-11 landing pad

    E-Print Network [OSTI]

    the Apollo-11 landing pad (arrow) was taken by the Lunar Reconnaissance Orbiter (LRO). It reveals hundreds of craters covering the landing area with sizes as small as 5 meters. The Apollo-11 landing pad is near and gives the surface density of craters near the Apollo-11 landing site in terms of craters per kilometer 2

  10. CONSTRUCTION BY REPLACEMENT: A NEW APPROACH TO SIMULATION MODELING

    E-Print Network [OSTI]

    CONSTRUCTION BY REPLACEMENT: A NEW APPROACH TO SIMULATION MODELING Authors: · James H Hines (MIT changes are needed. The paper describes an extensive experiment with using this approach to construct with another molecule. Using this tool kit, users can rapidly construct new simulation models by replacing

  11. Conveyorized Photoresist Stripping Replacement for Flex Circuit Fabrication

    SciTech Connect (OSTI)

    Megan Donahue

    2009-02-24T23:59:59.000Z

    A replacement conveyorized photoresist stripping system was characterized to replace the ASI photoresist stripping system. This system uses the qualified ADF-25c chemistry for the fabrication of flex circuits, while the ASI uses the qualified potassium hydroxide chemistry. The stripping process removes photoresist, which is used to protect the copper traces being formed during the etch process.

  12. RELIABILITY OF SAMPLING INSPECTION SCHEMES APPLIED TO REPLACEMENT STEAM GENERATORS

    E-Print Network [OSTI]

    Cizelj, Leon

    RELIABILITY OF SAMPLING INSPECTION SCHEMES APPLIED TO REPLACEMENT STEAM GENERATORS Guy Roussel the size of the random sample of tubes to be inspected in replacement steam generators is revisited in this paper. A procedure to estimate the maximum number of defective tubes left in the steam generator after

  13. Development of the prototype Munitions Case Moisture Meter, Model ORNL-1. Final report

    SciTech Connect (OSTI)

    Agouridis, D.C.; Gayle, T.M.; Griest, W.H.

    1993-02-24T23:59:59.000Z

    There is a great need for a rapid and simple means of determining the moisture content in combustible cartridge case (ccc) munitions. Previous studies have demonstrated that accumulation of moisture in ccc rounds, such as the M829, leads to softening of the case wall and weakening of the adhesive joint. Moisture in the ccc can lead to incomplete combustion of the case upon firing the round. Currently, there are no facile methods for measuring the moisture content. A prototype portable meter for non-destructive and rapid estimation of moisture in ccc has been developed. The Munitions Case Moisture Meter Model ORNL-1 demonstrates the feasibility of developing an instrument based on the moisture dependence of dielectric properties, to measure moisture in ccc munitions in storage and in the field. These instruments are simple, inexpensive, lightweight, portable, low-power battery operated, and intrinsically safe. They provide nondestructive, noninvasive, and rapid measurements. Calibration data for the prototype are not available at this time. Therefore, calibration of the meter and the development of a scale reading directly moisture content in munitions rounds could not be completed. These data will be supplied by the US Army from its tests of the meter with actual munitions. However, experimental results on empty cccs in laboratory conditions demonstrate satisfactory performance of the instrument. Additional work is needed to bring the prototype to its optimum usefulness and accuracy for field measurements. This includes: Calibration of the meter scale with full-up munitions; Data and evaluation procedures to adjust the performance of the meter for different environmental conditions such as temperature and humidity; and Studies of the dielectric properties of moist ccc materials, as a function of frequency and temperature, are needed for adjustment of the meter for optimal performance.

  14. Development of the prototype Munitions Case Moisture Meter, Model ORNL-1

    SciTech Connect (OSTI)

    Agouridis, D.C.; Gayle, T.M.; Griest, W.H.

    1993-02-24T23:59:59.000Z

    There is a great need for a rapid and simple means of determining the moisture content in combustible cartridge case (ccc) munitions. Previous studies have demonstrated that accumulation of moisture in ccc rounds, such as the M829, leads to softening of the case wall and weakening of the adhesive joint. Moisture in the ccc can lead to incomplete combustion of the case upon firing the round. Currently, there are no facile methods for measuring the moisture content. A prototype portable meter for non-destructive and rapid estimation of moisture in ccc has been developed. The Munitions Case Moisture Meter Model ORNL-1 demonstrates the feasibility of developing an instrument based on the moisture dependence of dielectric properties, to measure moisture in ccc munitions in storage and in the field. These instruments are simple, inexpensive, lightweight, portable, low-power battery operated, and intrinsically safe. They provide nondestructive, noninvasive, and rapid measurements. Calibration data for the prototype are not available at this time. Therefore, calibration of the meter and the development of a scale reading directly moisture content in munitions rounds could not be completed. These data will be supplied by the US Army from its tests of the meter with actual munitions. However, experimental results on empty cccs in laboratory conditions demonstrate satisfactory performance of the instrument. Additional work is needed to bring the prototype to its optimum usefulness and accuracy for field measurements. This includes: Calibration of the meter scale with full-up munitions; Data and evaluation procedures to adjust the performance of the meter for different environmental conditions such as temperature and humidity; and Studies of the dielectric properties of moist ccc materials, as a function of frequency and temperature, are needed for adjustment of the meter for optimal performance.

  15. Using Wireless Power Meters to Measure Energy Use of Miscellaneous and Electronic Devices in Buildings

    SciTech Connect (OSTI)

    UC Berkeley, Berkeley, CA USA; Brown, Richard; Lanzisera, Steven; Cheung, Hoi Ying (Iris); Lai, Judy; Jiang, Xiaofan; Dawson-Haggerty, Stephen; Taneja, Jay; Ortiz, Jorge; Culler, David

    2011-05-24T23:59:59.000Z

    Miscellaneous and electronic devices consume about one-third of the primary energy used in U.S. buildings, and their energy use is increasing faster than other end-uses. Despite the success of policies, such as Energy Star, that promote more efficient miscellaneous and electronic products, much remains to be done to address the energy use of these devices if we are to achieve our energy and carbon reduction goals. Developing efficiency strategies for these products depends on better data about their actual usage, but very few studies have collected field data on the long-term energy used by a large sample of devices due to the difficulty and expense of collecting device-level energy data. This paper describes the development of an improved method for collecting device-level energy and power data using small, relatively inexpensive wireless power meters. These meters form a mesh network based on Internet standard protocols and can form networks of hundreds of metering points in a single building. Because the meters are relatively inexpensive and do not require manual data downloading, they can be left in the field for months or years to collect long time-series energy use data. In addition to the metering technology, we also describe a field protocol used to collect comprehensive, robust data on the miscellaneous and electronic devices in a building. The paper presents sample results from several case study buildings, in which all the plug-in devices for several homes were metered, and a representative sample of several hundred plug-in devices in a commercial office building were metered for several months.

  16. Optical position meters analyzed in the non-inertial reference frames

    E-Print Network [OSTI]

    Sergey P. Tarabrin; Alexander A. Seleznyov

    2008-09-03T23:59:59.000Z

    In the framework of General Relativity we develop a method for analysis of the operation of the optical position meters in their photodetectors proper reference frames. These frames are non-inertial in general due to the action of external fluctuative forces on meters test masses, including detectors. For comparison we also perform the calculations in the laboratory (globally inertial) reference frame and demonstrate that for certain optical schemes laboratory-based analysis results in unmeasurable quantities, in contrast to the detector-based analysis. We also calculate the response of the simplest optical meters to weak plane gravitational waves and fluctuative motions of their test masses. It is demonstrated that for the round-trip meter analysis in both the transverse-traceless (TT) and local Lorentz (LL) gauges produces equal results, while for the forward-trip meter corresponding results differ in accordance with different physical assumptions (e.g. procedure of clocks synchronization) implicitly underlying the construction of the TT and LL gauges.

  17. EA-0923: Winnett School District Boiler Replacement Project, Winnett, Montana

    Broader source: Energy.gov [DOE]

    This EA evaluates the environmental impacts of the proposal to replace the Winnett School District complex's existing oil-fired heating system with a new coal-fired heating system with funds...

  18. Ultrasound image guided acetabular implant orientation during total hip replacement

    DOE Patents [OSTI]

    Chang, John; Haddad, Waleed; Kluiwstra, Jan-Ulco; Matthews, Dennis; Trauner, Kenneth

    2003-08-19T23:59:59.000Z

    A system for assisting in precise location of the acetabular implant during total hip replacement. The system uses ultrasound imaging for guiding the placement and orientation of the implant.

  19. Laboratory Evaluation of LED T8 Replacement Lamp Products

    SciTech Connect (OSTI)

    Richman, Eric E.; Kinzey, Bruce R.; Miller, Naomi J.

    2011-05-23T23:59:59.000Z

    A report on a lab setting analysis involving LED lamps intended to directly replace T8 fluorescent lamps (4') showing light output, power, and economic comparisons with other fluorescent options.

  20. Replacement of Data from IHS With Those from HPDI

    U.S. Energy Information Administration (EIA) Indexed Site

    Replacement of Data from IHS With Those from HPDI The EIA-914 estimation methodology published in September 2005 used data from IHS, Inc., as a source for calibration of historical...