National Library of Energy BETA

Sample records for retrofit existing buildings

  1. Retrofit Existing Buildings | Department of Energy

    Energy Savers [EERE]

    Commercial Buildings » Retrofit Existing Buildings Retrofit Existing Buildings Photo of the Denver skyline with Wells Fargo Center building in the center of the image and the Rocky Mountains in the background. Renovation, retrofit and refurbishment of existing buildings represent an opportunity to upgrade the energy performance of commercial building assets for their ongoing life. Often retrofit involves modifications to existing commercial buildings that may improve energy efficiency or

  2. Building America Technology Solutions for Existing Homes: Retrofit Measures

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    for Embedded Wood Member in Insulated Mass Masonry Walls | Department of Energy Existing Homes: Retrofit Measures for Embedded Wood Member in Insulated Mass Masonry Walls Building America Technology Solutions for Existing Homes: Retrofit Measures for Embedded Wood Member in Insulated Mass Masonry Walls In this project, the Building Science Corporation team studied a historic brick building in Lawrence, Massachusetts, which is being renovated into 10 condominium units and adding insulation to

  3. Building America Whole-House Solutions for Existing Home: Retrofitting...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Home: Retrofitting a 1960s Split-Level Cold-Climate Home The U.S. Department of Energy Building America team Consortium for Advanced Residential Buildings (CARB) partnered with...

  4. Building America Whole-House Solutions for Existing Homes: Evaluation of a Multifamily Retrofit

    Broader source: Energy.gov [DOE]

    Evaluation of a Multifamily Retrofit in Climate Zone 5, Boulder, Colorado (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)

  5. Technology Solutions for Existing Homes Case Study: Trade-Friendly Retrofit Insulated Panels for Existing Buildings

    Broader source: Energy.gov [DOE]

    For this project with the U.S. Department of Energy Building America team Home Innovation Research Labs, the retrofit insulated panels relied on an enhanced expanded polystyrene (EPS) for thermal...

  6. Building America Whole-House Solutions for Existing Home: Retrofitting a

    Energy Savers [EERE]

    1960s Split-Level Cold-Climate Home | Department of Energy Whole-House Solutions for Existing Home: Retrofitting a 1960s Split-Level Cold-Climate Home Building America Whole-House Solutions for Existing Home: Retrofitting a 1960s Split-Level Cold-Climate Home The U.S. Department of Energy Building America team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders and the owners of a 1960s split-level home in Westport, Connecticut, to evaluate and implement a

  7. Building America Technology Solutions for Existing Homes: Retrofit...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Member in Insulated Mass Masonry Walls In this project, the Building Science Corporation team studied a historic brick building in Lawrence, Massachusetts, which is being...

  8. Existing Homes Retrofit Case Study: Consortium for Advanced Residential Buildings (CARB), Washington, D.C.

    SciTech Connect (OSTI)

    2009-09-01

    This is a Building America fact sheet describing Consortium for Advanced Residential Buildiings (CARB) whole building retrofit process to renovate a 145-year-old home in Washington, D.C.

  9. Pilot Demonstration of Phased Retrofits in Florida Homes (Fact Sheet), Building America Case Study: Whole-House Solutions for Existing Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    Pilot Demonstration of Phased Retrofits in Florida Homes PROJECT INFORMATION Project Name: Pilot Demonstration of Phased Retrofits in Existing Florida Homes Partners: Building America Partnership for Improved Residential Construction, www.ba-pirc.org Florida Power & Light, www.fpl.com Location: Brevard, Collier, and Palm Beach Counties, Florida Application: Retrofit; Single-family Number of Homes: 60 Age Range: 1958-2006 Applicable Climate Zone(s): Hot-humid Year Tested: 2012-2013

  10. Building America Efficient Solutions for Existing Homes Case Study: Retrofit of 1915 Home, Dayton, Washington

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    15, this two-story, three-bedroom home with an unfinished basement and 2,600 ft 2 of living space is typical of many older homes found in eastern Washington. Through the U.S. Department of Energy's Building America program, researchers from the Pacific Northwest National Laboratory worked with local energy rater Energy Incentives, Inc., to assist the home owners in cost-effectively reducing their energy use by over 50%. The researchers used Energy Gauge USA simulation software to model retrofit

  11. Retrofit Ventilation Strategies in Multifamily Buildings Webinar

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Foundation Retrofits Building America Webinar November 30, 2011 Kohta Ueno Hybrid Foundation Retrofits 2 Background Hybrid Foundation Retrofits 3 Background  Space conditioning energy use for basements  Known moisture-safe solutions (previous research)  Persistent bulk water (leakage) issues  Retrofits of existing foundations  Especially uneven wall (rubble stone) foundations  "Hybrid" insulation and bulk water control assemblies Hybrid Foundation Retrofits 4

  12. Building America Webinar: Retrofit Ventilation Strategies in...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Retrofit Ventilation Strategies in Multifamily Buildings Webinar Building America Webinar: Retrofit Ventilation Strategies in Multifamily Buildings Webinar This webinar, presented ...

  13. National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet), Building America Case Study: Whole-House Solutions for Existing Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    National Grid Deep Energy Retrofit Pilot Massachusetts and Rhode Island PROJECT INFORMATION Construction: Deep energy retrofit (DER) Type: 37 comprehensive retrofits, 5 partial retrofits Housing Type: 31 single-family, 8 two- family, and 3 three-family dwellings Pilot Program Sponsor: National Grid, www.nationalgridus.com Technical Support Partner: Building Science Corporation, www.buildingscience.com Contractors: Various Projects Completed: 2009-2012 Climate Zone: Cold POST-RETROFIT PERFORMANCE

  14. Residential Building Audits and Retrofits

    Broader source: Energy.gov [DOE]

    This presentation covers local, regional, and national efforts to promote energy efficiency in residential buildings, programmatic elements of residential building audit and retrofit programs, and resources that you can access to address residential retrofit issues.

  15. Building America Webinar: Retrofitting Central Space Conditioning...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building America Webinar: Retrofitting Central Space Conditioning Strategies for ... Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings

  16. Applying Best Practices to Florida Local Government Retrofit Programs, Central Florida (Fact Sheet), Building America Case Study: Whole-House Solutions for Existing Homes, Building Technologies Office (BTO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Whole-House Solutions for Existing Homes Applying Best Practices to Florida Local Government Retrofit Programs Central Florida During 2009, 2010, and 2011, researchers of the U.S. Department of Energy's research team Building America Partnership for Improved Residential Construction (BA-PIRC) provided analysis and recommendations to eight affordable housing entities conduct- ing comprehensive renovations in 70 distressed, foreclosed homes in central Florida. Partners achieved a mutually agreed

  17. Evaluation of a Multifamily Retrofit in Climate Zone 5, Boulder, Colorado (Fact Sheet), Building America Case Study: Whole-House Solutions for Existing Homes, Building Technologies Office (BTO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    a Multifamily Retrofit in Climate Zone 5 Boulder, Colorado PROJECT INFORMATION Project Name: Evaluation of a Low-Rise Multifamily Retrofit in Boulder, CO Location: Boulder, CO Consortium of Advanced Residential Buildings www.carb-swa.com Building Component: Building envelope, lighting, appliances, water conservation Application: Retrofit Years Tested: 2012 Applicable Climate Zone(s): Cold, very cold PERFORMANCE DATA Cost of Energy Efficiency Measure (including labor): $3,300-$6,100 per unit with

  18. Stand-Off Furring in Deep Energy Retrofits, Syracuse, New York (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    Stand-Off Furring in Deep Energy Retrofits Syracuse, New York PROJECT INFORMATION Project Name: Deep Energy Retrofit Location: Syracuse, NY Project Partners: GreenHomes America, www.greenhomesamerica.com/ IBACOS, www.ibacos.com Building Component: Building envelope Application: Single-family retrofit Year Tested: 2012 Applicable Climate Zone(s): Cold PERFORMANCE DATA Cost of energy efficiency measure (including labor): $23,518 Projected energy savings: Approximately 50% overall savings Exterior

  19. Retrofit Integrated Space & Water Heating: Field Assessment, Minneapolis, Minnesota (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    Retrofit Integrated Space and Water Heating: Field Assessment Minneapolis, Minnesota PROJECT INFORMATION Project Name: Retrofit Integrated Space and Water Heating: Field Assessment Location: Minneapolis, MN Partners: Center for Energy and Environment, www.mncee.org/ Sustainable Resources Center, www.src-mn.org/ University of Minnesota, www.bbe.umn.edu/index.htm NorthernSTAR Building America Partnership Building Component: HVAC Application: Retrofit; single family Year Tested: 2012 Climate

  20. Retrofit Ventilation Strategies in Multifamily Buildings Webinar...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Retrofit Ventilation Strategies in Multifamily Buildings Webinar Retrofit Ventilation Strategies in Multifamily Buildings Webinar Slides from the Building America webinar on ...

  1. Building America Case Study: Greenbelt Homes, Inc. Pilot Retrofit Project, Greenbelt, Maryland (Fact Sheet), Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Greenbelt Homes, Inc. Pilot Retrofit Project Greenbelt, Maryland PROJECT INFORMATION Construction: Existing homes Builder: Greenbelt Homes, Inc., ghi.coop Type: Single-family, configured primarily in sets of 2, 4, or 6 attached homes Pilot Retrofit Project: Envelope upgrade study based on 7 4-unit buildings Size: 800-1,200 ft 2 Price Range: About $70,000-$300,000 Study Period: 2010-2014 Climate Zone: Mixed-humid (IECC climate zone 4A) PERFORMANCE DATA Average per Pilot Home, Normalized Season

  2. Building America Efficient Solutions for Existing Homes Case Study: Deep Energy Retrofit of 1910 House, Portland, Oregon

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    one-and-a-half-story, two-bedroom home with a half-basement is typical of 100-year-old homes in Portland, Oregon. The home had no insulation, an unfinished basement, old appliances and air leaks everywhere when purchased by its current owner in 2010. The owners performed a full deep energy retrofit, including air sealing and insulating exterior walls and attic and installing new, efficient appliances. Building America researchers from the Pacific Northwest National Laboratory audited the home

  3. Advanced Energy Retrofit Guide Office Buildings

    SciTech Connect (OSTI)

    Liu, Guopeng; Liu, Bing; Wang, Weimin; Zhang, Jian; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

    2011-09-27

    The Advanced Energy Retrofit Guide for Office Buildings is a component of the Department of Energys Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

  4. Advanced Energy Retrofit Guide Retail Buildings

    SciTech Connect (OSTI)

    Liu, Guopeng; Liu, Bing; Zhang, Jian; Wang, Weimin; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

    2011-09-19

    The Advanced Energy Retrofit Guide for Retail Buildings is a component of the Department of Energys Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

  5. Strengthening Building Retrofit Markets

    SciTech Connect (OSTI)

    Templeton, Mary; Jackson, Robert

    2014-04-15

    The Business Energy Financing (BEF) program offered commercial businesses in Michigan affordable financing options and other incentives designed to support energy efficiency improvements. We worked through partnerships with Michigan utilities, lenders, building contractors, trade associations, and other community organizations to offer competitive interest rates and flexible financing terms to support energy efficiency projects that otherwise would not have happened. The BEF program targeted the retail food market, including restaurants, grocery stores, convenience stores, and wholesale food vendors, with the goal of achieving energy efficiency retrofits for 2 percent of the target market. We offered low interest rates, flexible payments, easy applications and approval processes, and access to other incentives and rebates. Through these efforts, we sought to help customers strive for energy savings retrofits that would save 20 percent or more on their energy use. This program helped Michigan businesses reduce costs by financing energy efficient lighting, heating and cooling systems, insulation, refrigeration, equipment upgrades, and more. Businesses completed the upgrades with the help of our authorized contractors, and, through our lending partners, we provided affordable financing options.

  6. Building America Webinar: A National Summary of Deep Energy Retrofits |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy A National Summary of Deep Energy Retrofits Building America Webinar: A National Summary of Deep Energy Retrofits This presentation by Brennan Less is included in the Building America webinar, Who's Successfully Doing Deep Energy Retrofits?, on June 25, 2014. PDF icon BA Webinar_less_6-25-14.pdf More Documents & Publications Building America Whole-House Solutions for Existing Homes: National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet)

  7. Building America Expert Meeting: Interior Insulation Retrofit...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    America Expert Meeting: Interior Insulation Retrofit of Mass Masonry Wall Assemblies The Building Science Corporation team held an Expert Meeting on Interior Insulation Retrofit...

  8. Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit, Annapolis, Maryland (Fact Sheet), Building America Case Study: Whole-House Solutions for Existing Homes, Building Technologies Office (BTO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Bay Ridge Gardens-Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit Annapolis, Maryland PROJECT INFORMATION Construction: Existing Type: Apartment building: Bay Ridge Gardens Annapolis, MD www.bayridgegardens.com Size: 12 apartment units, 713 ft 2 and 909 ft 2 each Year of construction: 1970s Date completed: 2013 Climate Zone: Mixed-humid PERFORMANCE DATA Pre-retrofit annual energy use (normalized): 28.4 kilowatt-hour per square foot (kWh/ft 2 ) Post-retrofit annual energy use

  9. Building America Case Study: Retrofit Measure for Embedded Wood...

    Energy Savers [EERE]

    Existing Homes Building America Case Study Retrofit Measures for Embedded Wood Members in Insulated Mass Masonry Walls Lawrence, Massachusetts PROJECT INFORMATION Project Name: The...

  10. Building America Webinar: Retrofitting Central Space Conditioning...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building America Webinar: Retrofitting Central Space Conditioning Strategies for ... Building America Webinar: High Performance Enclosure Strategies: Part II, New Construction ...

  11. Building America Webinar: Retrofitting Central Space Conditioning...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Control strategies to improve hydronic space heating performance Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings - Control ...

  12. Building America Webinar: Retrofitting Central Space Conditioning

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Strategies for Multifamily Buildings - Steam Systems, Retrofit Measure Packages, Hydronic Systems | Department of Energy Steam Systems, Retrofit Measure Packages, Hydronic Systems Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings - Steam Systems, Retrofit Measure Packages, Hydronic Systems This presentation is included in the July 16, 2014, and provides information about best practices, costs, and savings associated with optimizing steam

  13. Building Energy Model Development for Retrofit Homes

    SciTech Connect (OSTI)

    Chasar, David; McIlvaine, Janet; Blanchard, Jeremy; Widder, Sarah H.; Baechler, Michael C.

    2012-09-30

    Based on previous research conducted by Pacific Northwest National Laboratory and Florida Solar Energy Center providing technical assistance to implement 22 deep energy retrofits across the nation, 6 homes were selected in Florida and Texas for detailed post-retrofit energy modeling to assess realized energy savings (Chandra et al, 2012). However, assessing realized savings can be difficult for some homes where pre-retrofit occupancy and energy performance are unknown. Initially, savings had been estimated using a HERS Index comparison for these homes. However, this does not account for confounding factors such as occupancy and weather. This research addresses a method to more reliably assess energy savings achieved in deep energy retrofits for which pre-retrofit utility bills or occupancy information in not available. A metered home, Riverdale, was selected as a test case for development of a modeling procedure to account occupancy and weather factors, potentially creating more accurate estimates of energy savings. This true up procedure was developed using Energy Gauge USA software and post-retrofit homeowner information and utility bills. The 12 step process adjusts the post-retrofit modeling results to correlate with post-retrofit utility bills and known occupancy information. The trued post retrofit model is then used to estimate pre-retrofit energy consumption by changing the building efficiency characteristics to reflect the pre-retrofit condition, but keeping all weather and occupancy-related factors the same. This creates a pre-retrofit model that is more comparable to the post-retrofit energy use profile and can improve energy savings estimates. For this test case, a home for which pre- and post- retrofit utility bills were available was selected for comparison and assessment of the accuracy of the true up procedure. Based on the current method, this procedure is quite time intensive. However, streamlined processing spreadsheets or incorporation into existing software tools would improve the efficiency of the process. Retrofit activity appears to be gaining market share, and this would be a potentially valuable capability with relevance to marketing, program management, and retrofit success metrics.

  14. Building America Case Study: Retrofitting a 1960s Split-Level, Cold-Climate Home, Westport, Connecticut (Fact Sheet), Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Retrofitting a 1960s Split-Level Cold-Climate Home Westport, Connecticut PROJECT INFORMATION Construction: Existing home Type: Single-family, split-level Partners: General Contractor: Preferred Builders, preferredbuilders.biz Consortium for Advanced Residential Buildings, carb-swa.com Size: 1,712 ft 2 Date Completed: 1960 Climate Zone: Cold (5A) PERFORMANCE DATA HERS Index: Pre-retrofit = 114 Post-retrofit: * With PV = 26 * Without PV = 56 Validated annual energy cost savings: * With PV = $4,032

  15. Building America Case Study: Innovative Retrofit Foundation Insulation Strategies, Minneapolis, Minnesota (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Innovative Retrofit Foundation Insulation Strategies Minneapolis, Minnesota PROJECT INFORMATION Project Name: Innovative Retrofit Foundation Insulation Strategies for Concrete Masonry Foundations Location: Minneapolis, MN NorthernSTAR Building America Partnership Building Component: Concrete block masonry foundation Application: Retrofit Year Tested: 2013 Climate Zones: Cold (6 and 7) PERFORMANCE DATA Cost of energy-efficiency measure (including labor): $4,600 Projected energy savings: 8.8% site

  16. Building America Webinar: Results from Phased Deep Retrofits in Florida |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Results from Phased Deep Retrofits in Florida Building America Webinar: Results from Phased Deep Retrofits in Florida This presentation by Danny Parker is included in the Building America webinar, Who's Successfully Doing Deep Energy Retrofits?, on June 25, 2014. PDF icon BA Webinar_parker_6-25-14.pdf More Documents & Publications Building America Team (BA-PIRC) - 2014 BTO Peer Review Building America Whole-House Solutions for Existing Homes: Pilot Demonstration of

  17. Building America Whole-House Solutions for Existing Homes: Greenbelt...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Greenbelt Homes, Inc. Pilot Retrofit Project - Greenbelt, Maryland Building America Whole-House Solutions for Existing Homes: Greenbelt Homes, Inc. Pilot Retrofit Project - ...

  18. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Retrofit Integrated Space and Water Heating-Field Assessment Building America Technology Solutions for New and Existing Homes: Retrofit Integrated Space and Water Heating-Field ...

  19. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Stand-off Furring in Deep Energy Retrofits Building America Technology Solutions for New and Existing Homes: Stand-off Furring in Deep Energy Retrofits This research project,...

  20. Building America Whole-House Solutions for Existing Homes: Group Home Energy Efficiency Retrofit for 30% Energy Savings (Fact Sheet)

    Broader source: Energy.gov [DOE]

    This project studies the specification, implementation, and energy savings from an energy efficiency retrofit in a group home, with an energy savings goal of 30%.

  1. Commercial Energy Efficiency Rebate for Existing Buildings

    Broader source: Energy.gov [DOE]

    Business customers retrofitting existing buildings through measures not covered under the standard incentive program can still receive financial assistance from Energy Trust through the custom...

  2. Evaluation of Crawlspace Retrofits in Multifamily Buildings

    SciTech Connect (OSTI)

    Rudd, Armin

    2014-09-01

    In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community unvented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring. The existing condition was a vented crawlspace with an uninsulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this unvented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods.

  3. Building Media, Inc. (Du Pont) (Building America Retrofit Alliance...

    Open Energy Info (EERE)

    America Retrofit Alliance) Place: Wilmington, DE Website: www.prweb.comreleasesDuPont References: Building America Retrofit Alliance Press Release1 BMI Website2 DuPont...

  4. Building America Webinar: Standardized Retrofit Packages - What Works to

    Energy Savers [EERE]

    Meet Consistent Levels of Performance? | Department of Energy Standardized Retrofit Packages - What Works to Meet Consistent Levels of Performance? Building America Webinar: Standardized Retrofit Packages - What Works to Meet Consistent Levels of Performance? This webinar focused on specific Building America projects that have examined methods to consistently meet high levels of energy performance in existing homes, with a focus on retrofit packages that can be replicated across many homes.

  5. Retrofit Ventilation Strategies in Multifamily Buildings Webinar |

    Energy Savers [EERE]

    Department of Energy Retrofit Ventilation Strategies in Multifamily Buildings Webinar Retrofit Ventilation Strategies in Multifamily Buildings Webinar Slides from the Building America webinar on November 30, 2011. PDF icon webinar_hybrid_insulation_20111130.pdf More Documents & Publications Building America Expert Meeting: Foundations Research Results Building America Expert Meeting: Interior Insulation Retrofit of Mass Masonry Wall Assemblies Building America Technology Solutions for

  6. Building America Webinar: Retrofitting Central Space Conditioning

    Energy Savers [EERE]

    Strategies for Multifamily Buildings | Department of Energy Retrofitting Central Space Conditioning Strategies for Multifamily Buildings Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings The webinar on July 16, 2014, focused on improving the performance of central space conditioning systems in multifamily buildings. Presenters discussed hydronic heating strategies and the evaluation of thermostatically controlled radiator valves (TRVs).

  7. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Insulation Strategies, Minneapolis, Minnesota Building America Technology Solutions for New and Existing Homes: Innovative Retrofit Foundation Insulation Strategies, ...

  8. Building America Whole-House Solutions for Existing Homes: Cascade Apartments- Deep Energy Multifamily Retrofit (Fact Sheet)

    Broader source: Energy.gov [DOE]

    In December of 2009-10, King County Housing Authority implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington, which resulted in annual energy cost savings of 22%, improved comfort and air quality for residents, and increased durability of the units.

  9. Building America Case Study: Sunnyvale Marine Climate Deep Retrofit, Sunnyvale, California (Fact Sheet), Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Sunnyvale Marine Climate Deep Retrofit Sunnyvale, California PROJECT INFORMATION Construction: Retrofit Type: Single-family Partners: Builder: One Sky Homes of San Jose, CA, oneskyhomes.com Alliance for Residential Building Innovation, arbi.davisenergycom Size: 1,658 ft 2 Vintage: 1957 Date completed: 2013 Climate Zone: Marine PERFORMANCE DATA Source energy savings: 54 MMBtu/yr (40%) Annual energy cost savings: $500 Incremental cost of energy-efficiency measures: $21,000 The U.S. Department of

  10. Existing Homes Retrofit Case Study: Asdal Builders, LLC, Pittsburgh, PA

    SciTech Connect (OSTI)

    None

    2009-09-01

    This Building America fact sheet describes a retrofit to improve efficiency of a 1930s era bungalow in Pittsburgh.

  11. Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit: Annapolis, Maryland. Building America Case Study: Whole-House Solutions for Existing Homes (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-10-01

    Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a "base scope" retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a "DER scope" which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

  12. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Innovative Retrofit Foundation Insulation Strategies, Minneapolis, Minnesota | Department of Energy Innovative Retrofit Foundation Insulation Strategies, Minneapolis, Minnesota Building America Technology Solutions for New and Existing Homes: Innovative Retrofit Foundation Insulation Strategies, Minneapolis, Minnesota In this project, the NorthernSTAR Building America Partnership evaluated a retrofit insulation strategy for foundations that is designed for use with open-core concrete block

  13. Evaluation of Crawlspace Retrofits in Multifamily Buildings

    SciTech Connect (OSTI)

    Rudd, A.

    2014-09-01

    In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community unvented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring. The existing condition was a vented crawlspace with an uninsulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this unvented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods. While the unvented crawlspace retrofit was effective in reducing heat loss, and the majority of the bulk water drainage problems had been resolved, the important finding was that some of the wood joists embedded in masonry pockets behind the brick veneer were showing signs of moisture damage.

  14. Building America Whole-House Solutions for Existing Homes: Applying...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building America Whole-House Solutions for Existing Homes: Applying Best Practices to Florida Local Government Retrofit Programs - Central Florida (Fact Sheet) Building America...

  15. Building America Whole-House Solutions for Existing Homes: Applying...

    Energy Savers [EERE]

    Retrofits in Florida Homes - Central and South Florida (Fact Sheet) Building America Efficient Solutions for Existing Homes: Case Study: Build San Antonio Green, San Antonio, Texas...

  16. Retrofit of a Multifamily Mass Masonry Building in New England

    SciTech Connect (OSTI)

    Ueno, K.; Kerrigan, P.; Wytrykowska, H.; Van Straaten, R.

    2013-08-01

    Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

  17. Building America Whole-House Solutions for Existing Homes: Cascade

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Apartments - Deep Energy Multifamily Retrofit (Fact Sheet) | Department of Energy Building America Whole-House Solutions for Existing Homes: Cascade Apartments - Deep Energy Multifamily Retrofit (Fact Sheet) Building America Whole-House Solutions for Existing Homes: Cascade Apartments - Deep Energy Multifamily Retrofit (Fact Sheet) This project implemented energy retrofit improvements in the Cascade multifamily community, which resulted in annual energy cost savings of 22%, improved comfort

  18. Building America Whole-House Solutions for Existing Homes: Cascade

    Energy Savers [EERE]

    Apartments - Deep Energy Multifamily Retrofit (Fact Sheet) | Department of Energy Building America Whole-House Solutions for Existing Homes: Cascade Apartments - Deep Energy Multifamily Retrofit (Fact Sheet) Building America Whole-House Solutions for Existing Homes: Cascade Apartments - Deep Energy Multifamily Retrofit (Fact Sheet) This project implemented energy retrofit improvements in the Cascade multifamily community, which resulted in annual energy cost savings of 22%, improved comfort

  19. A Retrofit Tool for Improving Energy Efficiency of Commercial Buildings

    SciTech Connect (OSTI)

    Levine, Mark; Feng, Wei; Ke, Jing; Hong, Tianzhen; Zhou, Nan

    2013-06-06

    Existing buildings will dominate energy use in commercial buildings in the United States for three decades or longer and even in China for the about two decades. Retrofitting these buildings to improve energy efficiency and reduce energy use is thus critical to achieving the target of reducing energy use in the buildings sector. However there are few evaluation tools that can quickly identify and evaluate energy savings and cost effectiveness of energy conservation measures (ECMs) for retrofits, especially for buildings in China. This paper discusses methods used to develop such a tool and demonstrates an application of the tool for a retrofit analysis. The tool builds on a building performance database with pre-calculated energy consumption of ECMs for selected commercial prototype buildings using the EnergyPlus program. The tool allows users to evaluate individual ECMs or a package of ECMs. It covers building envelope, lighting and daylighting, HVAC, plug loads, service hot water, and renewable energy. The prototype building can be customized to represent an actual building with some limitations. Energy consumption from utility bills can be entered into the tool to compare and calibrate the energy use of the prototype building. The tool currently can evaluate energy savings and payback of ECMs for shopping malls in China. We have used the tool to assess energy and cost savings for retrofit of the prototype shopping mall in Shanghai. Future work on the tool will simplify its use and expand it to cover other commercial building types and other countries.

  20. Building America Case Study: Exterior Insulation Pre- and Post-Retrofit, Syracuse, New York (Fact Sheet), Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Test House 1: * Pre-retrofit Btu/h: 82,502 * Post-retrofit Btu/h: 32,123 Test House 2: * Pre-retrofit Btu/h: 56,172 * Post-retrofit Btu/h: 22,591 Test House 3: * Pre-retrofit Btu/h: 97,560 * Post-retrofit Btu/h: 50,490 The U.S. Department of Energy Building America team, IBACOS, in collabora- tion with GreenHomes America, Inc. (GHA), contracted with the New York State Energy Research and Development Authority to research exterior wall insulation strategies that could be implemented as a part of

  1. Building America Case Study: Exterior Insulation Pre- and Post-Retrofit, Syracuse, New York (Fact Sheet), Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Total Heating and Cooling Peak Load Reduction Test House 1: * Pre-retrofit Btu/h: 114,989 * Post-retrofit Btu/h: 44,398 Test House 2: * Pre-retrofit Btu/h: 80,572 * Post-retrofit Btu/h: 31,330 Test House 3: * Pre-retrofit Btu/h: 139,744 * Post-retrofit Btu/h: 69,188 The U.S. Department of Energy Building America team, IBACOS, in collabora- tion with GreenHomes America, Inc. (GHA), contracted with the New York State Energy Research and Development Authority to research exterior wall insulation

  2. Building America Webinar: Retrofitting Central Space Conditioning

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Strategies for Multifamily Buildings - Control strategies to improve hydronic space heating performance | Department of Energy Control strategies to improve hydronic space heating performance Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings - Control strategies to improve hydronic space heating performance This presentation is included in the July 16, 2014, webinar and discusses various control strategies to improve hydronic space heating

  3. Building America Case Study: Performance of a Hot-Dry Climate Whole House Retrofit, Stockton, California (Fact Sheet), Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Study Performance of a Hot-Dry Climate Whole-House Retrofit Stockton, California PROJECT INFORMATION Construction: Whole-house retrofit Type: Single-family, affordable Partners: Builder: Green Home Solutions, greenbygrupe.com Alliance for Residential Building Innovation, http://arbi.davisenergy.com Size: 2,152 ft 2 Date completed: 2011 Climate Zone(s): Hot-Dry PERFORMANCE DATA HERS Index: Pre-retrofit rating = 314; post-retrofit rating = 156 Projected annual energy cost savings: $837 Incremental

  4. Building America Whole-House Solutions for Existing Homes: Cascade...

    Energy Savers [EERE]

    Homes: Cascade Apartments - Deep Energy Multifamily Retrofit (Fact Sheet) Building America Whole-House Solutions for Existing Homes: Cascade Apartments - Deep Energy Multifamily...

  5. Building America Whole-House Solutions for Existing Homes: Pilot...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Homes: Pilot Demonstration of Phased Retrofits in Florida Homes - Central and South Florida (Fact Sheet) Building America Whole-House Solutions for Existing Homes: Pilot ...

  6. Building America Whole-House Solutions for Existing Homes: Cascade...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of the units. PDF icon Cascade Apartments - Deep Energy Multifamily Retrofit - Kent, WA More Documents & Publications Building America Whole-House Solutions for Existing...

  7. Measured energy savings and economics of retrofitting existing single- family homes: An update of the BECA-B database

    SciTech Connect (OSTI)

    Cohen, S.D.; Goldman, C.A.; Harris, J.P.

    1991-02-01

    These appendices are the companion volume to report number LBL--28147 Vol.1, with the same title. The summary data tables include physical characteristics, energy consumption, savings, and the retrofit measures installed and their costs for each retrofit project. Each existing single family residential building'' retrofit project in the BECA-B database is described. 99 refs. (BM)

  8. Building America Case Study: Insulated Siding Retrofit in a Cold Climate. New Paltz, New York (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Insulated Siding Retrofit in a Cold Climate New Paltz, New York PROJECT INFORMATION Project Name: Insulated Siding Retrofit in a Cold Climate Location: New Paltz, NY Partners: Builder: Kinsley Construction Company, rkinsley.com Building America Partnership for Improved Residential Construction, ba-pirc.org Building Component: Building envelope-exterior cladding and water- resistive barrier Application: Retrofit, single-family Year Tested: 2012-2013 Climate Zones: Cold/very cold (4, 5, 6)

  9. Building America Webinar: Retrofitting Central Space Conditioning

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Strategies for Multifamily Buildings - Introduction | Department of Energy Introduction Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings - Introduction This presentation serves as the introduction to the Building America webinar held on July 16, 2014, and provided information about mproving the performance of central space conditioning systems in multifamily buildings. PDF icon BA_webinar_intro_7-16-14.pdf More Documents &

  10. Building America Case Study: Whole-House Solutions for Existing Homes: Greenbelt Homes, Inc. Pilot Retrofit Program; Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    SciTech Connect (OSTI)

    2015-06-01

    In the fall of 2010, a multiyear pilot energy efficiency retrofit project was undertaken by Greenbelt Homes, Inc, (GHI) a 1,566 home cooperative of circa 1930 and 1940 homes in Greenbelt, Maryland. GHI established this pilot project to serve as a basis for decision making for the rollout of a decade-long community-wide upgrade program that will incorporate energy efficiency improvements to the building envelope and mechanical equipment. With the community upgrade fully funded by the cooperative through their membership without outside subsidies, this project presents a unique opportunity to evaluate and prioritize the wide-range of benefits of high-performance retrofits based on member experience with and acceptance of the retrofit measures implemented during the pilot project. Addressing the complex interactions between benefits, trade-offs, construction methods, project management implications, realistic upfront costs, financing, and other considerations, serves as a case study for energy retrofit projects to include high-performance technologies based on the long-term value to the homeowner. The pilot project focused on identifying the added costs and energy savings benefits of improvements. Phase 1: baseline evaluation for a representative set of 28 homes sited in seven buildings; Phase 2: installation of the building envelope improvements and continued monitoring of the energy consumption for the heating season and energy simulations supporting recommendations for HVAC and water heating upgrades to be implemented in Phase 3.

  11. Building America Expert Meeting: Transforming Existing Buildings through

    Energy Savers [EERE]

    New Media--An Idea Exchange | Department of Energy Transforming Existing Buildings through New Media--An Idea Exchange Building America Expert Meeting: Transforming Existing Buildings through New Media--An Idea Exchange This report describes results of a Building America expert meeting on September 13, 2011, in Las Vegas, Nevada, hosted by the Building America Retrofit Alliance (BARA). This meeting provided a forum for presentations and discussions on the use of new media to work with

  12. Whole Foods Market Retrofits Multiple Building Systems for Big Savings

    SciTech Connect (OSTI)

    2013-03-01

    Whole Foods Market partnered with U.S. the Department of Energy (DOE) to develop and implement solutions to reduce annual energy consumption in existing stores by at least 30% versus pre-retrofit energy use at its store in Edgewater, New Jersey, as part of DOEs Commercial Building Partnership (CBP) program.

  13. Building America Efficient Solutions for Existing Homes Case Study:

    Energy Savers [EERE]

    Retrofit of 1915 Home, Dayton, Washington | Department of Energy Retrofit of 1915 Home, Dayton, Washington Building America Efficient Solutions for Existing Homes Case Study: Retrofit of 1915 Home, Dayton, Washington This case study lists project information, cost and energy efficiency performance data, energy efficiency measures and lessons learned for a 1915 home in eastern Washington audited by Pacific Northwest National Laboratory for an energy retrofit. The asbestos covered diesel

  14. Building America Whole-House Solutions for Existing Homes: Pilot

    Energy Savers [EERE]

    Demonstration of Phased Retrofits in Florida Homes - Central and South Florida (Fact Sheet) | Department of Energy Pilot Demonstration of Phased Retrofits in Florida Homes - Central and South Florida (Fact Sheet) Building America Whole-House Solutions for Existing Homes: Pilot Demonstration of Phased Retrofits in Florida Homes - Central and South Florida (Fact Sheet) In this pilot project, the Florida Solar Energy Center and Florida Power and Light are collaborating to retrofit a large

  15. Retrofit Incentives for Multifamily Buildings | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Multifamily Retrofits » Retrofit Incentives for Multifamily Buildings Retrofit Incentives for Multifamily Buildings The DOE Weatherization Assistance Program (Weatherization) is administered through state grantees that fund local or regional organizations to deliver services. When at least 66% of the residents of a multifamily building meet the Weatherization income eligibility requirements, the program can contribute resources toward energy retrofits in the building. Note that each DOE

  16. Building America Webinar: Deep Energy Retrofit Case Studies: Lessons

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Learned | Department of Energy Deep Energy Retrofit Case Studies: Lessons Learned Building America Webinar: Deep Energy Retrofit Case Studies: Lessons Learned This presentation by Alea German is included in the Building America webinar, Who's Successfully Doing Deep Energy Retrofits?, on June 25, 2014. PDF icon BA Webinar_german_6-25-14.pdf More Documents & Publications Building America Webinar: Introduction - Who's Successfully Doing Deep Energy Retrofits? Critical Question #8: When are

  17. Building America Case Study: Retrofitting a 1960s Split-Level, Cold-Climate Home, Westport, Connecticut; Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    SciTech Connect (OSTI)

    2015-08-01

    ??National programs such as Home Performance with ENERGY STAR(R) and numerous other utility air sealing programs have brought awareness to homeowners of the benefits of energy efficiency retrofits. Yet, these programs tend to focus on the low-hanging fruit: air-sealing the thermal envelope and ductwork where accessible, switch to efficient lighting, and low-flow fixtures. At the other end of the spectrum, deep-energy retrofit programs are also being encouraged by various utilities across the country. While deep energy retrofits typically seek 50% energy savings, they are often quite costly and most applicable to gut-rehab projects. A significant potential for lowering energy usage in existing homes lies between the low hanging fruit and deep energy retrofit approaches - retrofits that save approximately 30% in energy over the existing conditions. A key is to be non-intrusive with the efficiency measures so the retrofit projects can be accomplished in occupied homes. This cold climate retrofit project involved the design and optimization of a home in Connecticut that sought to improve energy savings by at least 30% (excluding solar PV) over the existing home's performance. This report documents the successful implementation of a cost-effective solution package that achieved performance greater than 30% over the pre-retrofit - what worked, what did not, and what improvements could be made. Confirmation of successfully achieving 30% source energy savings over the pre-existing conditions was confirmed through energy modeling and comparison of the utility bills pre- and post- retrofit.

  18. Existing Homes Retrofit Case Study: SMUD's Energy Efficient Remodel Demonstration Project

    SciTech Connect (OSTI)

    2010-10-01

    Building America worked with SMUD on this 1980s retrofit home to cut energy use by 104 points from a pre-retrofit California HERS score of 182 to a post retrofit score of 78.

  19. Building America Technology Solutions for New and Existing Homes: Insulated

    Energy Savers [EERE]

    Siding Retrofit in a Cold Climate, New Paltz, New York | Department of Energy Insulated Siding Retrofit in a Cold Climate, New Paltz, New York Building America Technology Solutions for New and Existing Homes: Insulated Siding Retrofit in a Cold Climate, New Paltz, New York In this study, the U.S. Department of Energy's team Building America Partner-ship for Improved Residential Construction (BA-PIRC) worked with Kinsley Construction Company to evaluate the real-world performance of insulated

  20. Building America Technology Solutions for New and Existing Homes: Durable

    Energy Savers [EERE]

    Interior Foundation Insulation Retrofits for Cold Climates, Cloquet, Minnesota | Department of Energy Durable Interior Foundation Insulation Retrofits for Cold Climates, Cloquet, Minnesota Building America Technology Solutions for New and Existing Homes: Durable Interior Foundation Insulation Retrofits for Cold Climates, Cloquet, Minnesota Thermal and moisture problems in existing basements create a unique challenge as the exterior face of the wall is not easily or inexpensively accessible.

  1. Building America Efficient Solutions for Existing Homes: Case Study: Build

    Energy Savers [EERE]

    San Antonio Green, San Antonio, Texas | Department of Energy Homes: Case Study: Build San Antonio Green, San Antonio, Texas Building America Efficient Solutions for Existing Homes: Case Study: Build San Antonio Green, San Antonio, Texas PNNL, FSEC, and CalcsPlus provided technical assistance to Build San Antonio Green on three deep energy retrofits. For this gut rehab they replaced the old roof with a steeper roof and replaced drywall while adding insulation, new HVAC, sealed ducts, transfer

  2. Building America Whole-House Solutions for Existing Homes: Performance of a

    Energy Savers [EERE]

    Hot-Dry Climate Whole-House Retrofit, Stockton, California (Fact Sheet) | Department of Energy Performance of a Hot-Dry Climate Whole-House Retrofit, Stockton, California (Fact Sheet) Building America Whole-House Solutions for Existing Homes: Performance of a Hot-Dry Climate Whole-House Retrofit, Stockton, California (Fact Sheet) The Alliance for Residential Building Innovation (ARBI) team conducted a deep retrofit project within Stockton's Large-Scale Retrofit Program that expanded on the

  3. Building America Expert Meeting: Interior Insulation Retrofit of Mass

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Masonry Wall Assemblies | Department of Energy Interior Insulation Retrofit of Mass Masonry Wall Assemblies Building America Expert Meeting: Interior Insulation Retrofit of Mass Masonry Wall Assemblies The Building Science Corporation team held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011, at the Westford Regency Hotel in Westford, MA. Featured speakers included John Straube, Christopher Schumacher and Kohta Ueno of Building Science

  4. Building America Expert Meeting: Interior Insulation Retrofit of Mass

    Energy Savers [EERE]

    Masonry Wall Assemblies | Department of Energy Interior Insulation Retrofit of Mass Masonry Wall Assemblies Building America Expert Meeting: Interior Insulation Retrofit of Mass Masonry Wall Assemblies The Building Science Corporation team held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011, at the Westford Regency Hotel in Westford, MA. Featured speakers included John Straube, Christopher Schumacher and Kohta Ueno of Building Science

  5. Building America Expert Meeting: Retrofit Implementation - A Neighborhood

    Energy Savers [EERE]

    at a Time | Department of Energy Retrofit Implementation - A Neighborhood at a Time Building America Expert Meeting: Retrofit Implementation - A Neighborhood at a Time This report provides information about a Building America expert meeting hosted by research team Consortium for Advanced Residential Buildings on October 25, 2011, in New York City. The meeting discussed several community residential retrofit projects underway across the United States, and included representatives from

  6. Building America Webinar: Who's Successfully Doing Deep Energy Retrofits? |

    Energy Savers [EERE]

    Department of Energy Who's Successfully Doing Deep Energy Retrofits? Building America Webinar: Who's Successfully Doing Deep Energy Retrofits? The webinar on June 25, 2014, focused on specific Building America projects that highlighted real-world examples of deep energy retrofits (DER) that are meeting with technical and market success. Presenters focused on technical strategies, modeled and actual performance results, and project costs. Danny Parker, Building America Partnership for

  7. Building America Efficient Solutions for Existing Homes Case Study: Deep

    Energy Savers [EERE]

    Energy Retrofit of 1910 House, Portland, Oregon | Department of Energy Deep Energy Retrofit of 1910 House, Portland, Oregon Building America Efficient Solutions for Existing Homes Case Study: Deep Energy Retrofit of 1910 House, Portland, Oregon This case study lists project information, cost and energy efficiency performance data, energy efficiency measures and lessons learned for a 100-year-old home in Portland, Oregon, audited by Pacific Northwest National Laboratory for a deep energy

  8. Building America Whole-House Solutions for Existing Homes: Exterior

    Energy Savers [EERE]

    Insulation Pre- and Post-Retrofit, Syracuse, New York | Department of Energy Exterior Insulation Pre- and Post-Retrofit, Syracuse, New York Building America Whole-House Solutions for Existing Homes: Exterior Insulation Pre- and Post-Retrofit, Syracuse, New York IBACOS, in collaboration with GreenHomes America, Inc., was contracted by the New York State Energy Research and Development Authority to research exterior wall insulation solutions for enclosure upgrades. This case study describes

  9. Better Buildings Financing Energy Efficiency Retrofits in the...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Better Buildings Financing Energy Efficiency Retrofits in the Commercial Sector -- Part 1 Slides ... PDF icon Webinar slides More Documents & Publications May 4, 2011 - Financing ...

  10. Building America Webinar: Introduction- Who's Successfully Doing Deep Energy Retrofits?

    Broader source: Energy.gov [DOE]

    This presentation provides the introduction for the Building America webinar, Who's Successfully Doing Deep Energy Retrofits, presented on June 25, 2014.

  11. Existing Homes Retrofit Case Study: SMUD's 32nd Avenue Remodel Demonstration Program, Sacramento, CA

    SciTech Connect (OSTI)

    none,

    2011-03-01

    This case study describes a retrofit project between SMUD and Building America to create a high-performance home.

  12. Building America Whole-House Solutions for Existing Homes: Community...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building America Whole-House Solutions for Existing Homes: Community-Scale Energy Modeling ... To that end, IBACOS analyzed pre-retrofit daily utility data to sort homes by energy ...

  13. Building America Expert Meeting: Transforming Existing Buildings...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Transforming Existing Buildings through New Media--An Idea Exchange Building America Expert Meeting: Transforming Existing Buildings through New Media--An Idea Exchange This report...

  14. Text-Alternative Version of Building America Webinar: Retrofitting Central

    Energy Savers [EERE]

    Space Conditioning Strategies for Multifamily Buildings | Department of Energy Retrofitting Central Space Conditioning Strategies for Multifamily Buildings Text-Alternative Version of Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings Gail Werren: Hello, everyone I am Gail Werren with the National Renewable Energy Laboratory and I'd like to welcome you to today's webinar hosted by the Building America program. We're excited to have

  15. Building America Webinar: A National Summary of Deep Energy Retrofits...

    Energy Savers [EERE]

    Whole-House Solutions for Existing Homes: National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet) 2015 Race to Zero Competition Winner Team Summaries...

  16. DOE Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings

    Broader source: Energy.gov [DOE]

    The Building America Program is hosting a no-cost, webinar-based training on Retrofitting Central Space Conditioning Strategies for Multifamily Buildings. The webinar will focus on improving the...

  17. City of Los Angeles- Green Building Retrofit Requirement

    Broader source: Energy.gov [DOE]

    In April 2009, Los Angeles enacted Ordinance 180636, known as the Green Building Retrofit Ordinance. This ordinance was later amended by Ordinance 182259. The law requires all city-owned buildings...

  18. Energy Innovation Hub Report Shows Philadelphia-area Building Retrofits

    Office of Environmental Management (EM)

    Could Support 23,500 Jobs | Department of Energy Innovation Hub Report Shows Philadelphia-area Building Retrofits Could Support 23,500 Jobs Energy Innovation Hub Report Shows Philadelphia-area Building Retrofits Could Support 23,500 Jobs November 10, 2011 - 10:36am Addthis This is the Greater Philadelphia Innovation Cluster located at the Philadelphia Navy Yard, which has 270 buildings that consortium members can use to conduct energy efficiency experiments. The Energy Efficiency Buildings

  19. Analysis of institutional mechanisms affecting residential and commercial buildings retrofit

    SciTech Connect (OSTI)

    Not Available

    1980-09-01

    Barriers to energy conservation in the residential and commercial sectors influence (1) the willingness of building occupants to modify their energy usage habits, and (2) the willingness of building owners/occupants to upgrade the thermal characteristics of the structures within which they live or work and the appliances which they use. The barriers that influence the willingness of building owners/occupants to modify the thermal efficiency characteristics of building structures and heating/cooling systems are discussed. This focus is further narrowed to include only those barriers that impede modifications to existing buildings, i.e., energy conservation retrofit activity. Eight barriers selected for their suitability for Federal action in the residential and commercial sectors and examined are: fuel pricing policies that in the short term do not provide enough incentive to invest in energy conservation; high finance cost; inability to evaluate contractor performance; inability to evaluate retrofit products; lack of well-integrated or one-stop marketing systems (referred to as lack of delivery systems); lack of precise or customized information; lack of sociological/psychological incentives; and use of the first-cost decision criterion (expanded to include short-term payback criterion for the commercial sector). The impacts of these barriers on energy conservation are separately assessed for the residential and commercial sectors.

  20. Building America Technology Solutions for New and Existing Homes: Stand-off

    Energy Savers [EERE]

    Furring in Deep Energy Retrofits | Department of Energy Stand-off Furring in Deep Energy Retrofits Building America Technology Solutions for New and Existing Homes: Stand-off Furring in Deep Energy Retrofits This research project, conducted by IBACOS and GreenHomes America, investigated cost-effective deep energy retrofit (DER) solutions for improving the building shell exterior while achieving a cost-reduction goal, including reduced labor costs to reach a 50/50 split between material and

  1. Building America Whole-House Solutions for Existing Homes: National Grid

    Energy Savers [EERE]

    Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet) | Department of Energy National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet) Building America Whole-House Solutions for Existing Homes: National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet) Building Science Corporation developed a package of high-efficiency measures for retrofit of 42 homes sponsored by National Grid, resulting in energy use of

  2. Building America Whole-House Solutions for Existing Homes: Applying Best Practices to Florida Local Government Retrofit Programs- Central Florida (Fact Sheet)

    Broader source: Energy.gov [DOE]

    In this project, researchers from Building America Partnership for Improved Residential Construction worked with the City of Melbourne, Florida, to develop and implement best practices for renovating distressed homes to achieve annual energy savings of 15%-30% and higher

  3. Retrofit of a MultiFamily Mass Masonry Building in New England

    SciTech Connect (OSTI)

    Ueno, K.; Kerrigan, P.; Wytrykowska, H.; Van Straaten, R.

    2013-08-01

    Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

  4. Deep Energy Retrofit Guidance for the Building America Solutions Center

    SciTech Connect (OSTI)

    Less, Brennan; Walker, Iain

    2015-01-01

    The U.S. DOE Building America program has established a research agenda targeting market-relevant strategies to achieve 40% reductions in existing home energy use by 2030. Deep Energy Retrofits (DERs) are part of the strategy to meet and exceed this goal. DERs are projects that create new, valuable assets from existing residences, by bringing homes into alignment with the expectations of the 21st century. Ideally, high energy using, dated homes that are failing to provide adequate modern services to their owners and occupants (e.g., comfortable temperatures, acceptable humidity, clean, healthy), are transformed through comprehensive upgrades to the building envelope, services and miscellaneous loads into next generation high performance homes. These guidance documents provide information to aid in the broader market adoption of DERs.

  5. Building America Whole-House Solutions for Existing Homes: Applying Best

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Practices to Florida Local Government Retrofit Programs - Central Florida (Fact Sheet) | Department of Energy Building America Whole-House Solutions for Existing Homes: Applying Best Practices to Florida Local Government Retrofit Programs - Central Florida (Fact Sheet) Building America Whole-House Solutions for Existing Homes: Applying Best Practices to Florida Local Government Retrofit Programs - Central Florida (Fact Sheet) In this project, researchers from Building America Partnership for

  6. Building America Whole-House Solutions for Existing Homes: Applying Best

    Energy Savers [EERE]

    Practices to Florida Local Government Retrofit Programs - Central Florida (Fact Sheet) | Department of Energy Building America Whole-House Solutions for Existing Homes: Applying Best Practices to Florida Local Government Retrofit Programs - Central Florida (Fact Sheet) Building America Whole-House Solutions for Existing Homes: Applying Best Practices to Florida Local Government Retrofit Programs - Central Florida (Fact Sheet) In this project, researchers from Building America Partnership for

  7. Building America Webinar: Deep Energy Retrofit Case Studies:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    This presentation by Alea German is included in the Building America webinar, Who's Successfully Doing Deep Energy Retrofits?, on June 25, 2014. PDF icon BA Webinargerman6-25-14....

  8. Critical Question #1: How Do We Retrofit the Tough Buildings?

    Broader source: Energy.gov [DOE]

    What are strategies in designing air sealing and insulation solutions for energy retrofits of the more challenging buildings? What are some examples of durable solutions that are relatively inexpensive? What hasn't worked and why? What looks promising?

  9. Better Buildings Financing Energy Efficiency Retrofits in the Commercial

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Sector -- Part 1 | Department of Energy Financing Energy Efficiency Retrofits in the Commercial Sector -- Part 1 Better Buildings Financing Energy Efficiency Retrofits in the Commercial Sector -- Part 1 Slides from the Better Buildings webinar presented on May 4, 2011: Survey of Small Commercial Energy Efficiency Finance Programs Sponsored by State Governments Oregon Energy Loan: Financingg Oregon Energy Efficiency and Renewable Energy Abundant Power Solutions ADECA Leveraged Clean Energy

  10. Existing Homes Retrofit Case Study: Yakama Nation Housing Authority, Wapato, WA

    SciTech Connect (OSTI)

    2009-09-01

    This is a Building America fact sheet describing the Yakama Nation Housing Authority's retrofit of 25 homes on the reservation to make them more energy efficient.

  11. Existing Homes Retrofit Case Study: SMUD's Jean Avenue Remodel Demonstration Program, Sacramento, CA

    SciTech Connect (OSTI)

    none,

    2011-03-01

    This case study describes how SMUD teamed with Building America partners to retrofit aging, foreclosed homes into high-performance homes.

  12. Data and Analytics to Inform Energy Retrofit of High Performance Buildings

    SciTech Connect (OSTI)

    Hong , Tianzhen; Yang, Le; Hill, David; Feng , Wei

    2014-01-25

    Buildings consume more than one-third of the world?s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis ? energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high performance building in California to analyze its energy use and identify retrofit opportunities, including: (1) analyzing patterns of major energy end-use categories at various time scales, (2) benchmarking the whole building total energy use as well as major end-uses against its peers, (3) benchmarking the power usage effectiveness for the data center, which is the largest electricity consumer in this building, and (4) diagnosing HVAC equipment using detailed time-series operating data. Finally, a few energy efficiency measures were identified for retrofit, and their energy savings were estimated to be 20percent of the whole-building electricity consumption. Based on the analyses, the building manager took a few steps to improve the operation of fans, chillers, and data centers, which will lead to actual energy savings. This study demonstrated that there are energy retrofit opportunities for high performance buildings and detailed measured building performance data and analytics can help identify and estimate energy savings and to inform the decision making during the retrofit process. Challenges of data collection and analytics were also discussed to shape best practice of retrofitting high performance buildings.

  13. Building America Technology Solutions for New and Existing Homes: Steam

    Energy Savers [EERE]

    System Balancing and Tuning for Multifamily Residential Buildings, Chicago, Illinois (Fact Sheet) | Department of Energy Steam System Balancing and Tuning for Multifamily Residential Buildings, Chicago, Illinois (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Steam System Balancing and Tuning for Multifamily Residential Buildings, Chicago, Illinois (Fact Sheet) The Partnership for Advanced Residential Retrofit (PARR), a U.S. Department of Energy Building

  14. Building America Whole-House Solutions for Existing Homes: Greenbelt Homes,

    Energy Savers [EERE]

    Inc. Pilot Retrofit Project - Greenbelt, Maryland | Department of Energy Greenbelt Homes, Inc. Pilot Retrofit Project - Greenbelt, Maryland Building America Whole-House Solutions for Existing Homes: Greenbelt Homes, Inc. Pilot Retrofit Project - Greenbelt, Maryland This multiyear pilot energy efficiency retrofit project was undertaken by Greenbelt Homes, Inc, (GHI) a 1,566 home cooperative of circa 1930 and 1940 homes, to serve as a basis for decision making for the rollout of a

  15. Building America Technology Solutions for New and Existing Homes: Cladding

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Attachment Over Mineral Fiber Insulation Board - Ontario, Canada | Department of Energy Cladding Attachment Over Mineral Fiber Insulation Board - Ontario, Canada Building America Technology Solutions for New and Existing Homes: Cladding Attachment Over Mineral Fiber Insulation Board - Ontario, Canada This case study describes a high performance enclosure retrofit package that uses mineral fiber insulation board and describes retrofit assembly and details for wood frame roof and walls and for

  16. Building America Best Practices Series, Vol. 10 - Retrofit Techniques &

    Energy Savers [EERE]

    Technologies: Air Sealing, A Guide for Contractors to Share with Homeowners | Department of Energy Series, Vol. 10 - Retrofit Techniques & Technologies: Air Sealing, A Guide for Contractors to Share with Homeowners Building America Best Practices Series, Vol. 10 - Retrofit Techniques & Technologies: Air Sealing, A Guide for Contractors to Share with Homeowners This guide provides information to contractors and homeowners to identify ways to seal unwanted air leaks in homes, while

  17. Building America Technology Solutions for New and Existing Homes: Advanced

    Energy Savers [EERE]

    Boiler Load Monitoring Controllers, Chicago, Illinois | Department of Energy Boiler Load Monitoring Controllers, Chicago, Illinois Building America Technology Solutions for New and Existing Homes: Advanced Boiler Load Monitoring Controllers, Chicago, Illinois In this project, the Building America team Partnership for Advanced Residential Retrofit (PARR) installed and monitored an ALM aftermarket controller, the M2G from Greffen Systems, at two Chicago area multifamily buildings with existing

  18. An actuarial approach to retrofit savings in buildings

    SciTech Connect (OSTI)

    Subbarao, Krishnappa; Etingov, Pavel V.; Reddy, T. A.

    2014-01-01

    An actuarial method has been developed for determining energy savings from retrofits from energy use data for a number of buildings. This method should be contrasted with the traditional method of using pre- and post-retrofit data on the same building. This method supports the U.S. Department of Energy Building Performance Database of real building performance data and related tools that enable engineering and financial practitioners to evaluate retrofits. The actuarial approach derives, from the database, probability density functions (PDFs) for energy savings from retrofits by creating peer groups for the user’s pre post buildings. From the energy use distribution of the two groups, the savings PDF is derived. This provides the basis for engineering analysis as well as financial risk analysis leading to investment decisions. Several technical issues are addressed: The savings PDF is obtained from the pre- and post-PDF through a convolution. Smoothing using kernel density estimation is applied to make the PDF more realistic. The low data density problem can be mitigated through a neighborhood methodology. Correlations between pre and post buildings are addressed to improve the savings PDF. Sample size effects are addressed through the Kolmogorov--Smirnov tests and quantile-quantile plots.

  19. Sustainability in Existing Federal Buildings | Department of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Facilities Sustainable Buildings & Campuses Sustainability in Existing Federal Buildings Sustainability in Existing Federal Buildings The General Services Administration ...

  20. Building America Technology Solutions for New and Existing Homes:

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Combustion Safety Using Appliances for Indoor Air (Fact Sheet) | Department of Energy Building America Technology Solutions for New and Existing Homes: Combustion Safety Using Appliances for Indoor Air (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Combustion Safety Using Appliances for Indoor Air (Fact Sheet) In this case study, the Partnership for Advanced Residential Retrofit team provides guidance on how to assess and carry out the combustion safety

  1. Building America Webinar: Who's Successfully Doing Deep Energy Retrofits?

    Broader source: Energy.gov [DOE]

    The webinar will focus on specific Building America projects and case studies that highlight real-world examples of deep energy retrofits that are meeting with technical and market success. Presenters will focus on technical strategies, modeled and actual performance results, and project costs.

  2. Existing Homes Retrofit Case Study: Chesapeake Habitat for Humanity, Baltimore, MD

    SciTech Connect (OSTI)

    2009-09-01

    This is a Building America fact sheet on the Chesapeake Habitat for Humanity's rowhouse retrofit project, where four row houses in Baltimore, Maryland, were made energy efficient for low-income residents.

  3. Building America Retrofit Participation Requirements and Release

    Broader source: Energy.gov [DOE]

    This form is for Building America team members and homeowners to complete verifying health and safety requirements have been met.

  4. Building America Whole-House Solutions for Existing HomesBay Ridge Gardens

    Energy Savers [EERE]

    - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit, Annapolis, Maryland (Fact Sheet) | Department of Energy HomesBay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit, Annapolis, Maryland (Fact Sheet) Building America Whole-House Solutions for Existing HomesBay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit, Annapolis, Maryland (Fact Sheet) Approximately 43% energy savings are achieved in a 1970s multifamily

  5. Building America Technology Solutions for New and Existing Homes: Measure

    Energy Savers [EERE]

    Guideline: Guidance on Taped Insulating Sheathing Drainage Planes | Department of Energy Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes Building America Technology Solutions for New and Existing Homes: Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes This project by Building Science Corporation focuses on the field implementation of taped board insulation as the drainage plane in both new and retrofit residential applications. PDF icon

  6. Sustainability in Existing Federal Buildings

    Broader source: Energy.gov [DOE]

    For meeting federal sustainability requirements, agencies can use evaluation methods, such as benchmarking and energy audits, and planning to make existing buildings energy efficient. Agencies can follow these steps to comply with energy reduction requirements.

  7. Building America Webinar: Retrofitting Central Space Conditioning...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Jordan Dentz and Hugh Henderson, Advanced Residential Integrated Energy Solutions (ARIES), ... three low-rise multifamily buildings in Cambridge, MA. Presenters showed results from an ...

  8. Building America Expert Meeting: Retrofit Implementation - A...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Implementation - A Neighborhood at a Time This report provides information about a Building America expert meeting hosted by research team Consortium for Advanced...

  9. How Do We Retrofit the Tough Buildings

    Broader source: Energy.gov [DOE]

    This presentation was delivered at the U.S. Department of Energy Building America Technical Update meeting on April 29-30, 2013, in Denver, Colorado.

  10. Evaluation of CNT Energy Savers Retrofit Packages Implemented in Multifamily Buildings

    SciTech Connect (OSTI)

    Farley, Jenne; Ruch, Russell

    2013-09-01

    This evaluation explored the feasibility of designing prescriptive retrofit measure packages for typical Chicago region multifamily buildings in order to achieve 25%-30% source energy savings through the study of three case studies. There is an urgent need to scale up energy efficiency retrofitting of Chicago's multifamily buildings in order to address rising energy costs and a rapidly depleting rental stock. Aimed at retrofit program administrators and building science professionals, this research project investigates the possibility of using prescriptive retrofit packages as a time- and resource-effective approach to the process of retrofitting multifamily buildings.

  11. Existing Whole-House Case Study: Sunnyvale Marine Climate Deep Retrofit - Sunnyvale, California

    SciTech Connect (OSTI)

    2015-03-01

    In this project, the Building America team Alliance for Residential Building Innovation and Allen Gilliland of One Sky Homes collaborated on a marine climate retrofit project designed to meet both Passive House and Building America program standards. The scope included sealing, installing wall, roof and floor insulation (previously lacking), replacing windows, and upgrading the heating and cooling system.

  12. Automated Auditing Tool for Retrofit Building Projects

    Energy Science and Technology Software Center (OSTI)

    2011-06-23

    Building energy auditors regularly use notepads, physical forms, or simple spreadsheets to inventory energy consuming devices in buildings and audit overall performance. Mobile computing devices such as smart phones or tablet computers with camera inputs may be used to automatically capture relevant information and format audit input in a way that streamlines work flows and reduces the likelihood of error. As an example. an auditor could walk through a space holding a mobile device, whichmore » automatically identifies and appliances, windows, etc. This information would automatically be added to a mobile database associated with the building for later integration with a larger building audit database. The user experience would require little or no manual input, and could integrate with tools to automate used to automate data collection for building energy modeling.« less

  13. Building America Whole-House Solutions for Existing Homes: Evaluation...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Boulder, Colorado More Documents & Publications Building America Expert Meeting: Retrofit Implementation - A Neighborhood at a Time Building America Residential Energy Efficiency...

  14. Business Case for Energy Efficient Building Retrofit and Renovation

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    SmartMarket Report Produced with support from Energy Efficient Business Case for Energy Efficient Building Retrofit and Renovation Funding provided by U.S. Department of Energy through the Pacific Northwest National Laboratory McGraw-Hill Construction President Keith Fox Vice President, Product Development Kathryn E. Cassino McGraw-Hill Construction Research & Analytics/Alliances Vice President, Industry Insights & Alliances Harvey M. Bernstein, F. ASCE, LEED AP Senior Director, Research

  15. Existing Whole-House Solutions Case Study: Performance of a Hot-Dry Climate Whole-House Retrofit, Stockton, California

    SciTech Connect (OSTI)

    2014-09-01

    The Alliance for Residential Building Innovation (ARBI) team conducted a deep retrofit project within Stocktons Large-Scale Retrofit Program that expanded on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Post-retrofit site energy savings were 23% compared to the pre-retrofit case.

  16. Walmart - Saving Energy, Saving Money Through Comprehensive Retrofits, Commercial Building Energy Efficiency (Fact Sheet); Energy Efficiency & Renewable Energy (EERE)

    SciTech Connect (OSTI)

    2015-03-01

    Walmart partnered with the U.S. Department of Energy (DOE) in 2009 to develop and demonstrate energy retrofits for existing buildings. The goal was to reduce energy consumption by at least 30% versus ASHRAE Standard 90.1-2007, as part of DOE's Commercial Building Partnerships (CBP) Program. The project presented here, the retrofit of a 213,000 square foot store in Centennial, Colorado, withefficiency measures across multiple building systems, is part of Walmart's ongoing environmental sustainability program, which originated in 2005.

  17. Building America Efficient Solutions for Existing Homes Case Study: Habitat

    Energy Savers [EERE]

    for Humanity South Sarasota County, Venice, Florida | Department of Energy Habitat for Humanity South Sarasota County, Venice, Florida Building America Efficient Solutions for Existing Homes Case Study: Habitat for Humanity South Sarasota County, Venice, Florida PNNL and Calcs Plus helped the South Sarasota County Florida Habitat for Humanity retrofit a 1978 single-story home by stripping old drywall, air sealing concrete block walls, and installing rigid insulation, furring strips, and new

  18. Building America Technology Solutions for New and Existing Homes: Replacing

    Energy Savers [EERE]

    Resistance Heating with Mini-Split Heat Pumps | Department of Energy Replacing Resistance Heating with Mini-Split Heat Pumps Building America Technology Solutions for New and Existing Homes: Replacing Resistance Heating with Mini-Split Heat Pumps In this project, the Advanced Residential Integrated Solutions team investigated the suitability of mini-split heat pumps for multifamily retrofits. PDF icon Replacing Resistance Heating with Mini-Split Heat Pumps More Documents & Publications

  19. Standard Measurement and Verification Plan for Lighting Retrofit Projects for Buildings and Building Sites

    SciTech Connect (OSTI)

    Richman, Eric E.

    2012-10-31

    This document provides a framework for standard measurement and verification (M&V) of lighting retrofit and replacement projects. It was developed to provide site owners, contractors, and other involved organizations with the essential elements of a robust M&V plan for lighting projects. It includes details on all aspects of effectively measuring light levels of existing and post-retrofit projects, conducting power measurement, and developing cost-effectiveness analysis. This framework M&V plan also enables consistent comparison among similar lighting projects, and may be used to develop M&V plans for non--lighting-technology retrofits and new installations.

  20. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    The Partnership for Advanced Residential Retrofit (PARR), a U.S. Department of Energy Building America team, conducted a study to identify best practices,costs, and savings...

  1. Building America Whole-House Solutions for Existing Homes: National...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Massachusetts and Rhode Island (Fact Sheet) Building Science Corporation developed a package of high-efficiency measures for retrofit of 42 homes sponsored by National Grid,...

  2. Existing Whole-House Solutions Case Study: Greenbelt Homes, Inc. Pilot Retrofit Project

    SciTech Connect (OSTI)

    2015-06-01

    In the fall of 2010, a multiyear pilot energy efficiency retrofit project was undertaken by Greenbelt Homes, Inc., (GHI) a 1,566 home cooperative of circa 1930 and 1940 homes in Greenbelt, Maryland. GHI established this pilot project to serve as a basis for decision making for the rollout of a community-wide upgrade program that will incorporate energy efficiency improvements to the building envelope and mechanical equipment. With the community upgrade fully funded by the cooperative through their membership without outside subsidies, this project presents a unique opportunity to evaluate and prioritize the wide range of benefits of high-performance retrofits based on member experience with and acceptance of the retrofit measures implemented during the pilot project. Addressing the complex interactions between benefits, trade-offs, construction methods, project management implications, realistic upfront costs, financing, and other considerations, serves as a case study for energy retrofit projects that include high-performance technologies based on the long-term value to the homeowner. The pilot project focused on identifying the added costs and energy-savings benefits of improvements. Phase 1baseline evaluation for a representative set of 28 homes sited in seven buildings; Phase 2installation of the building envelope improvements and continued monitoring of the energy consumption for the heating season; Phase 3energy simulations supporting recommendations for HVAC and water heating upgrades.

  3. Existing Commercial Reference Buildings Constructed Before 1980 |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Before 1980 Existing Commercial Reference Buildings Constructed Before 1980 The files on this page contain commercial reference building models for existing buildings constructed before 1980, organized by building type and location. These U.S. Department of Energy (DOE) reference buildings are complete descriptions for whole building energy analysis. You can also return to a summary of building types and climate zones and information about other building vintages. These

  4. Building America Webinar: Results from Phased Deep Retrofits in Florida

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Phased Deep Retrofits in Florida D. Parker, D. Chasar, K. Sutherland, J. Montemurno, J. Kono Florida Solar Energy Center June, 2014 Phased Deep Retrofit (PDR) Project * Detailed residential field metering project in FPL Service Territory * Cooperative project between U.S. DOE and FPL * Sixty heavily metered homes evaluated over 2 years * Shallow retrofit in all & then deep retrofits in 10 * Collecting data of unique value to FPL/DOE PDR: Extensive end-use metering * January - July 2013: 60

  5. Building America Performance Analysis Procedures for Existing Homes

    SciTech Connect (OSTI)

    Hendron, R.

    2006-05-01

    Because there are more than 101 million residential households in the United States today, it is not surprising that existing residential buildings represent an extremely large source of potential energy savings. Because thousands of these homes are renovated each year, Building America is investigating the best ways to make existing homes more energy-efficient, based on lessons learned from research in new homes. The Building America program is aiming for a 20%-30% reduction in energy use in existing homes by 2020. The strategy for the existing homes project of Building America is to establish technology pathways that reduce energy consumption cost-effectively in American homes. The existing buildings project focuses on finding ways to adapt the results from the new homes research to retrofit applications in existing homes. Research activities include a combination of computer modeling, field demonstrations, and long-term monitoring to support the development of integrated approaches to reduce energy use in existing residential buildings. Analytical tools are being developed to guide designers and builders in selecting the best approaches for each application. Also, DOE partners with the U.S. Environmental Protection Agency (EPA) to increase energy efficiency in existing homes through the Home Performance with ENERGY STAR program.

  6. Research update, existing buildings research, 1989--1991

    SciTech Connect (OSTI)

    MacDonald, J.M.; Ternes, M.P.; Mixon, W.R.; Sharp, T.R.; Kolb, J.O.; Wilkes, K.E. ); Diamond, R.C. ); Judkoff, R. ); Mazzucchi, R.P. )

    1993-02-01

    This Research Update presents the status of the Existing Buildings Research program of the Office of Building Technologies of the US Department of Energy for the period 1989-199 1. This program covers research on energy efficiency improvements for the residential and commercial buildings in this country. ne Existing Buildings Research program has contributed to significant improvements in energy efficiency of existing buildings by development of improvements to retrofit technologies, by coordinating and conducting research studies on the use of energy efficiency technologies (to reduce barriers and increase use), and by continually evaluating changes in technologies that could improve and maintain buildings energy efficiency. If the energy efficiency of the buildings sector in this country is to be dramatically improved over the next 30 years, we must improve the use of energy efficiency technologies. Improved delivery of measures, improved understanding of how buildings actually perform in the field, and methods for improving operations and maintenance of buildings and energy equipment are all examples of ways to improve the deployment (transfer) of technologies. Much has been learned about technology deployment in buildings in the first five years of the program, and our future plans will be directed at continuing the improvements and making a real contribution to the energy efficiency future of the United States.

  7. Building America Webinar: Retrofit Ventilation Strategies in Multifamily Buildings Webinar

    Broader source: Energy.gov [DOE]

    This webinar, presented by research team Building Science Corporation, discussed insulating foundations and controlling water leakage as a critical measure for reducing heating load in homes in cold climates.

  8. Building America Performance Analysis Procedures for Existing Homes

    SciTech Connect (OSTI)

    Hendron, Robert

    2006-05-01

    This report provides a proposed set of guidelines for estimating the energy savings achieved by a package of retrofits or an extensive rehabilitation of an existing home.

  9. Existing Whole-House Solutions Case Study: Evaluation of a Multifamily Retrofit in Climate Zone 5, Boulder, Colorado

    SciTech Connect (OSTI)

    2013-11-01

    In 2009, a 37-unit apartment complex located in Boulder, Colorado, underwent an energy retrofit to comply with Boulder SmartRegs Ordinance, a mandate that requires all rental properties to meet certain energy efficiency standards by 2018. The Consortium of Advanced Residential Buildings (CARB), a U.S. Department of Energy Building America team, worked with city planners and building owners to evaluate this program and recently completed a case study evaluating the effectiveness of a collection of retrofit measures.

  10. Building America Efficient Solutions for Existing Homes: Case Study: Build San Antonio Green, San Antonio, Texas

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    researchers provided technical assistance to Build San Antonio Green (BSAG, www.buildsagreen.org) for three of their deep energy and green retrofits. BSAG is a well established non-profit organization in the community that has certified more than 710 new homes as well as 15 retrofits through its Green Retrofit Program to date. Technical assistance provided by the Pacific Northwest National Laboratory (PNNL) team included retrofitting strategy assessments, performance testing, quality assurance,

  11. Existing Whole-House Solutions Case Study: Cascade Apartments - Deep Energy Multifamily Retrofit

    SciTech Connect (OSTI)

    2014-02-01

    In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington, which resulted in annual energy cost savings of 22%, improved comfort and air quality for residents, and increased durability of the units. This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary Building America research questions: 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio of the retrofit package after considering utility window incentives and KCHA capital improvement funding.

  12. State Energy Program (SEP) Strengthening Building Retrofit Markets and Stimulating Energy Efficiency Action

    Broader source: Energy.gov [DOE]

    National Energy Technology Laboratory (NETL) presentation on State Energy Program (SEP) Strengthening Building Retrofit Markets and Stimulating Energy Efficiency Action DE-FOA-0000251, Stimulating Energy Efficiency Action from State Public Utility Commissions DE-FOA-0000266

  13. Decision process for the retrofit of municipal buildings with solar energy systems: a technical guide

    SciTech Connect (OSTI)

    Licciardello, Michael R.; Wood, Brian; Dozier, Warner; Braly, Mark; Yates, Alan

    1980-11-01

    As a background for solar applications, the following topics are covered: solar systems and components for retrofit installations; cost, performance, and quality considerations; and financing alternatives for local government. The retrofit decision process is discussed as follows: pre-screening of buildings, building data requirements, the energy conservation audit, solar system sizing and economics, comparison of alternatives, and implementation. Sample studies are presented for the West Valley Animal Shelter and the Hollywood Police Station. (MHR)

  14. Existing Whole-House Solutions Case Study: Retrofitting a 1960s Split-Level Cold-Climate Home

    SciTech Connect (OSTI)

    S. Puttagunta

    2015-08-01

    ??National programs such as Home Performance with ENERGY STAR and numerous other utility air sealing programs have brought awareness to homeowners of the benefits of energy efficiency retrofits. Yet, these programs tend to focus on the low-hanging fruit: air-sealing the thermal envelope and ductwork where accessible, switch to efficient lighting, and low-flow fixtures. At the other end of the spectrum, deep-energy retrofit programs are also being encouraged by various utilities across the country. While deep energy retrofits typically seek 50% energy savings, they are often quite costly and most applicable to gut-rehab projects. A significant potential for lowering energy usage in existing homes lies between the low hanging fruit and deep energy retrofit approaches - retrofits that save approximately 30% in energy over the existing conditions.

  15. Building America Efficient Solutions for Existing Homes: Case...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    PNNL, FSEC, and CalcsPlus provided technical assistance to Build San Antonio Green on three deep energy retrofits. For this gut rehab they replaced the old roof with a steeper roof ...

  16. Existing Whole-House Solutions Case Study: Group Home Energy Efficiency Retrofit for 30% Energy Savings, Washington, D.C.

    SciTech Connect (OSTI)

    2013-11-01

    Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost-effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the studys results will be used to identify cost effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

  17. Existing Whole-House Solutions Case Study: National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island

    SciTech Connect (OSTI)

    2014-03-01

    Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. Thirty-seven of these projects were comprehensive retrofits while five were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. Building Science Corporation developed a consistent "package" of measures in terms of the performance targeted for major building components. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects, and was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

  18. Existing Whole-House Solutions Case Study: Pilot Demonstration of Phased Retrofits in Florida Homes - Central and South Florida Homes

    SciTech Connect (OSTI)

    2014-08-01

    In this pilot project, the Building America Partnership for Improved Residential Construction and Florida Power and Light are collaborating to retrofit a large number of homes using a phased approach to both simple and deep retrofits. This project will provide the information necessary to significantly reduce energy use through larger community-scale projects in collaboration with utilities, program administrators and other market leader stakeholders.

  19. Building America Webinar: High Performance Building Enclosures: Part I, Existing Homes

    Broader source: Energy.gov [DOE]

    This webinar, presented on May 21, 2014, focused on specific Building America projects that have implemented technical solutions to retrofit building enclosures to reduce energy use and improve durability.

  20. Energy and Cost Savings of Retro-Commissioning and Retrofit Measures for Large Office Buildings

    SciTech Connect (OSTI)

    Wang, Weimin; Zhang, Jian; Moser, Dave; Liu, Guopeng; Athalye, Rahul A.; Liu, Bing

    2012-08-03

    This paper evaluates the energy and cost savings of seven retro-commissioning measures and 29 retrofit measures applicable to most large office buildings. The baseline model is for a hypothetical building with characteristics of large office buildings constructed before 1980. Each retro-commissioning measure is evaluated against the original baseline in terms of its potential of energy and cost savings while each retrofit measure is evaluated against the commissioned building. All measures are evaluated in five locations (Miami, Las Vegas, Seattle, Chicago and Duluth) to understand the impact of weather conditions on energy and cost savings. The results show that implementation of the seven operation and maintenance measures as part of a retro-commissioning process can yield an average of about 22% of energy use reduction and 14% of energy cost reduction. Widening zone temperature deadband, lowering VAV terminal minimum air flow set points and lighting upgrades are effective retrofit measures to be considered.

  1. Analysis of Pre-Retrofit Building and Utility Data

    SciTech Connect (OSTI)

    Prahl, D.; Beach, R.

    2014-12-01

    IBACOS analyzed pre-retrofit daily utility data to sort homes by energy consumption, allowing for better targeting of homes for physical audits. Following ASHRAE Guideline 14 normalization procedures, electricity consumption of 1,166 all electric production-built homes was modeled. The homes were in two communitiesone built in the 1970s and the other in the mid-2000s.

  2. Analysis of Pre-Retrofit Building and Utility Data

    SciTech Connect (OSTI)

    Prahl, D.; Beach, R.

    2014-12-01

    IBACOS analyzed pre-retrofit daily utility data to sort homes by energy consumption, allowing for better targeting of homes for physical audits. Following ASHRAE Guideline 14 normalization procedures, electricity consumption of 1,166 all electric production-built homes' was modeled. The homes were in two communities -- one built in the 1970s and the other in the mid-2000s.

  3. Strategy Guideline: Energy Retrofits for Low-Rise Multifamily Buildings in Cold Climates

    SciTech Connect (OSTI)

    Frozyna, K.; Badger, L.

    2013-04-01

    This Strategy Guideline explains the benefits of evaluating and identifying energy efficiency retrofit measures that could be made during renovation and maintenance of multifamily buildings. It focuses on low-rise multifamily structures (three or fewer stories) in a cold climate. These benefits lie primarily in reduced energy use, lower operating and maintenance costs, improved durability of the structure, and increased occupant comfort. This guideline focuses on retrofit measures for roof repair or replacement, exterior wall repair or gut rehab, and eating system maintenance. All buildings are assumed to have a flat ceiling and a trussed roof, wood- or steel-framed exterior walls, and one or more single or staged boilers. Estimated energy savings realized from the retrofits will vary, depending on the size and condition of the building, the extent of efficiency improvements, the efficiency of the heating equipment, the cost and type of fuel, and the climate location.

  4. Expert Meeting Report: Transforming Existing Buildings through New Media--An Idea Exchange

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Transforming Existing Buildings through New Media - An Idea Exchange Stacy Hunt Building America Retrofit Alliance (BARA) May 2012 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, subcontractors, or affiliated partners makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or

  5. Building America Best Practices Series, Volume 10: Retrofit Techniques and Technologies: Air Sealing

    SciTech Connect (OSTI)

    Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.; Cole, Pamala C.; Williamson, Jennifer L.; Love, Pat M.

    2010-04-12

    This report was prepared by PNNL for the U.S. Department of Energy Building America Program. The report provides information to home owners who want to make their existing homes more energy efficient by sealing leaks in the building envelope (ceiling, walls, and floors) that let in drafts and let conditioned air escape. The report provides descriptions of 19 key areas of the home where air sealing can improve home performance and energy efficiency. The report includes suggestions on how to find a qualified weatherization or home performance contractor, what to expect in a home energy audit, opportune times for performing air sealing, and what safety and health concerns to be aware of. The report describes some basic building science concepts and topics related to air sealing including ventilation, diagnostic tools, and code requirements. The report will be available for free download from the DOE Building America website. It is a suitable consumer education tool for home performance and weatherization contractors to share with customers to describe the process and value of home energy retrofits.

  6. Building America Webinar: Who's Successfully Doing Deep Energy Retrofits?

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Who's Successfully Doing Deep Energy Retrofits (DER)? Moderator: Gail Werren - National Renewable Energy Laboratory Panelists: Danny Parker - Florida Solar Energy Center Alea German - Davis Energy Group Brennan Less- Lawrence Berkeley National Laboratory June 25, 2014 Some Housekeeping Items Two Options for Audio (select audio mode): 1. Listen through your computer. Please select the "mic and speakers" radio button on the right hand audio pane display 2. Listen by telephone. Please

  7. Byggmeister Test Home. Cold Climate Multifamily Masonry Building Condition Assessment and Retrofit Analysis

    SciTech Connect (OSTI)

    Wytrykowska, H.; Ueno, K.; Van Straaten, R.

    2012-09-01

    This report describes a retrofit project undertaken by Building Science Corporation and partner Byggmeister on a multifamily brick row house located in Jamaica Plain, MA. This project studied the row house to determine the right combination of energy efficiency measures that are feasible, affordable, and suitable for this type of construction and acceptable to homeowners.

  8. Byggmeister Test Home: Cold Climate Multifamily Masonry Building Condition Assessment and Retrofit Analysis

    SciTech Connect (OSTI)

    Wytrykowska, H.; Ueno, K.; Van Straaten, R.

    2012-09-01

    This report describes a retrofit project undertaken by Building Science Corporation and partner Byggmeister on a multifamily brick row house located in Jamaica Plain, MA. This project studied the row house to determine the right combination of energy efficiency measures that are feasible, affordable, and suitable for this type of construction and acceptable to homeowners.

  9. Prologis Rolls Out Warehouse Energy Retrofits

    SciTech Connect (OSTI)

    2013-03-01

    Prologis partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce annual energy consumption by at least 30% versus pre-retrofit energy use as part of DOEs Commercial Building Partnership (CBP) program.

  10. Business Case for Energy Efficient Building Retrofit and Renovation...

    Energy Savers [EERE]

    PDF icon businesscaseforenergyefficiencyretrofitrenovationsmr2011.pdf More Documents & Publications Energy Efficiency Trends in Residential and Commercial Buildings - ...

  11. Building America Technology Solutions for New and Existing Homes: Moisture Durability of Vapor Permeable Insulating Sheathing (Fact Sheet)

    Broader source: Energy.gov [DOE]

    In this project, Building America team Building Science Corporation researched some of the ramifications of using exterior, vapor permeable insulation on retrofit walls with vapor permeable cavity insulation. Retrofit strategies are a key factor in reducing exterior building stock consumption.

  12. Demonstration of Energy Efficient Retrofits for Lighting and Daylighting in New York City Office Buildings

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    INSERT PROJECT SPECIFIC PHOTO (replacing this shape) Demonstration of Energy Efficient Retrofits for Lighting and Daylighting in New York City Office Buildings 2015 Building Technologies Office Peer Review Eleanor Lee, eslee@lbl.gov Lawrence Berkeley National Laboratory Project Summary Timeline: Start date: October 1, 2013 Planned end date: December 31, 2015 Key Milestones 1. Partner commitment to Living Lab investment, 1/31/14 2. Initial implementation, 6/14, 8/14 3. Final technical report,

  13. Building America Webinar: Results from Phased Deep Retrofits...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    on June 25, 2014. PDF icon BA Webinarparker6-25-14.pdf More Documents & Publications Building America Team (BA-PIRC) - 2014 BTO Peer Review Building America Whole-House...

  14. Text-Alternative Version of Building America Webinar: Retrofitting...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... So now I'm going to move onto building three which is a study of the indoor temperature cut off and in building three we installed the system also, sometimes called an EMS system ...

  15. New Jersey SmartStart Buildings- New Construction and Retrofits

    Broader source: Energy.gov [DOE]

    New Jersey SmartStart Buildings is a program sponsored by the New Jersey Board of Public Utilities in partnership with New Jersey’s gas and electric utilities. New Jersey SmartStart Buildings rec...

  16. Building Retrofit and DSM Study in Jiangsu | Open Energy Information

    Open Energy Info (EERE)

    Natural Resources Defense Council Sector Energy Focus Area Buildings, Energy Efficiency Topics Background analysis, Pathways analysis, Policiesdeployment programs Resource...

  17. Building Energy Simulation Test for Existing Homes (BESTEST-EX) Methodology: Preprint

    SciTech Connect (OSTI)

    Judkoff, R.; Polly, B.; Bianchi, M.; Neymark, J.

    2011-11-01

    The test suite represents a set of cases applying the new Building Energy Simulation Test for Existing Homes (BESTEST-EX) Methodology developed by NREL. (Judkoff et al. 2010a). The NREL team developed the test cases in consultation with the home retrofit industry (BESTEST-EX Working Group 2009), and adjusted the test specifications in accordance with information supplied by a participant with access to large utility bill datasets (Blasnik 2009).

  18. Building America Whole-House Solutions for Existing Homes: Community-Scale

    Energy Savers [EERE]

    Energy Modeling - Southeastern United States | Department of Energy Community-Scale Energy Modeling - Southeastern United States Building America Whole-House Solutions for Existing Homes: Community-Scale Energy Modeling - Southeastern United States Community-scale energy modeling and testing are useful for determining energy conservation measures that will effectively reduce energy use. To that end, IBACOS analyzed pre-retrofit daily utility data to sort homes by energy consumption,

  19. Building America Case Study: Performance of a Hot-Dry Climate Whole House Retrofit, Stockton, California (Fact Sheet)

    SciTech Connect (OSTI)

    ARBI

    2014-09-01

    The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.

  20. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cambridge, Massachusetts Building America Technology Solutions for New and Existing Homes: Boiler Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, ...

  1. Cost-Effective Wall Retrofit Solution for the Interior Side of Building's Exterior Wall that Supports a Phased Retrofit Cost Model- 2014 BTO Peer Review

    Broader source: Energy.gov [DOE]

    Presenter: Amy Wylie, Bayer MaterialScience/Penn State Consortium In order to achieve the required airtight envelope, commercial buildings with masonry facades in Climate Zones 4 and 5 are faced with the decision between vapor-permeable or impermeable insulation, as well as whether retrofits are needed to implement continuous insulation instead of conventional discontinuous insulation.

  2. Building America Whole-House Solutions for Existing HomesBay...

    Broader source: Energy.gov (indexed) [DOE]

    43% energy savings are achieved in a 1970s multifamily building through standard, non-invasive retrofit measures. Bay Ridge Gardens-Mixed Humid Affordable Multifamily Housing Deep...

  3. Expert Meeting Report: Transforming Existing Buildings through New Media - An Idea Exchange

    SciTech Connect (OSTI)

    Hunt, Stacy

    2012-05-01

    This report describes results of a Building America expert meeting on September 13, 2011, in Las Vegas, Nevada, hosted by the Building America Retrofit Alliance (BARA). This meeting provided a forum for presentations and discussions on the use of new media to work with remodelers and retrofit projects to improve energy efficiency and deliver research results from the Building America program to remodelers.

  4. Expert Meeting Report: Transforming Existing Buildings through New Media--An Idea Exchange

    SciTech Connect (OSTI)

    Hunt, S.

    2012-05-01

    This report describes results of a Building America expert meeting on September 13, 2011, in Las Vegas, Nevada, hosted by the Building America Retrofit Alliance (BARA). This meeting provided a forum for presentations and discussions on the use of new media to work with remodelers and retrofit projects to improve energy efficiency and deliver research results from the Building America program to remodelers.

  5. Greenbelt Homes Pilot Program: Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings

    SciTech Connect (OSTI)

    Wiehagen, J.; Del Bianco, M.; Mallay, D.

    2015-05-01

    In the fall of 2010, a multiyear pilot energy efficiency retrofit project was undertaken by Greenbelt Homes, Inc, (GHI) a 1,566 home cooperative of circa 1930 and 1940 homes in Greenbelt, Maryland. GHI established this pilot project to serve as a basis for decision making for the rollout of a decade-long community-wide upgrade program that will incorporate energy efficiency improvements to the building envelope and mechanical equipment. It presents a unique opportunity to evaluate and prioritize the wide-range of benefits of high-performance retrofits based on member experience with and acceptance of the retrofit measures implemented during the pilot project. Addressing the complex interactions between benefits, trade-offs, construction methods, project management implications, realistic upfront costs, financing, and other considerations, serves as a case study for energy retrofit projects to include high-performance technologies based on the long-term value to the homeowner. The pilot project focused on identifying the added costs and energy savings benefits of improvements.

  6. Hydronic Heating Retrofits for Low-Rise Multifamily Buildings

    SciTech Connect (OSTI)

    Dentz, Jordan; Henderson, Hugh

    2012-04-01

    The ARIES Collaborative, a Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, MA to implement and study improvements to the heating system in one of the non-profits housing developments. The heating control systems in the 42-unit Columbia CAST housing development were upgraded in an effort projected to reduce heating costs by 15% to 25%.

  7. Cost-effective Interior Wall Retrofit Solutions for Commercial Building Shells

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cost-effective Interior Wall Retrofit Solutions for Commercial Building Shells 2014 Building Technologies Office Peer Review Flexible Research Platform (FRP) at Oak Ridge National Laboratory Amy Wylie, amy.wylie@bayer.com Bayer MaterialScience/Penn State Consortium Project Summary Timeline: Start date & Planned end date: Phase I June 1st, 2013 to Oct. 1st, 2014 Phase II May 1, 2014 to Apr 30, 2016 Key Milestones 1. Collect FRP baseline data (PHI - 6/14) 2. Research wall assembly &

  8. CBEI - Packaged Masonry Wall Retrofit Solutions for Small and Medium sized Commercial Buildings

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Packaged Masonry Wall Retrofit Solutions for Small and Medium sized Commercial Buildings 2015 Building Technologies Office Peer Review Mugdha Mokashi, mugdha.mokashi@bayer.com CBEI (Bayer MaterialScience ) Project Summary Timeline: Start date & Planned end date: Phase(PH) I June 1st, 2013 to Oct. 1st, 2014 Phase(PH) II May 1, 2014 to Apr 30, 2016 Key Milestones 1. Collect FRP baseline data (Oct 2014) 2. Demonstrate down-selected top- performing scenarios on the Flexible Research Platform

  9. Deep Residential Retrofits in East Tennessee

    SciTech Connect (OSTI)

    Boudreaux, Philip R; Hendrick, Timothy P; Christian, Jeffrey E; Jackson, Roderick K

    2012-04-01

    Executive Summary Oak Ridge National Laboratory (ORNL) is furthering residential energy retrofit research in the mixed-humid climate of East Tennessee by selecting 10 homes and guiding the homeowners in the energy retrofit process. The homeowners pay for the retrofits, and ORNL advises which retrofits to complete and collects post-retrofit data. This effort is in accordance with the Department of Energy s Building America program research goal of demonstrating market-ready energy retrofit packages that reduce home energy use by 30 50%. Through this research, ORNL researchers hope to understand why homeowners decide to partake in energy retrofits, the payback of home energy retrofits, and which retrofit packages most economically reduce energy use. Homeowner interviews help the researchers understand the homeowners experience. Information gathered during the interviews will aid in extending market penetration of home energy retrofits by helping researchers and the retrofit industry understand what drives homeowners in making positive decisions regarding these retrofits. This report summarizes the selection process, the pre-retrofit condition, the recommended retrofits, the actual cost of the retrofits (when available), and an estimated energy savings of the retrofit package using EnergyGauge . Of the 10 households selected to participate in the study, only five completed the recommended retrofits, three completed at least one but no more than three of the recommended retrofits, and two households did not complete any of the recommended retrofits. In the case of the two homes that did none of the recommended work, the pre-retrofit condition of the homes and the recommended retrofits are reported. The five homes that completed the recommended retrofits are monitored for energy consumption of the whole house, appliances, space conditioning equipment, water heater, and most of the other circuits with miscellaneous electric loads (MELs) and lighting. Thermal comfort is also monitored, with temperature and humidity measured in all conditioned zones, attics, crawlspaces, and unconditioned basements. In some homes, heat flux transducers are installed on the basement walls to help determine the insulating qualities of the technologies and practices. EnergyGauge is used to estimate the pre-retrofit and post-retrofit home energy rating system (HERS) index and reduction in energy consumption and energy bill. In a follow-up report, data from the installed sensors will be presented and analyzed as well as a comparison of the post-retrofit energy consumption of the home to the EnergyGauge model of the post-retrofit home. Table ES1 shows the retrofits that were completed at the eight households where some or all of the recommended retrofits were completed. Home aliases are used to keep the homeowners anonymous. Some key findings of this study thus far are listed as follows. Some homeowners (50%) are not willing to spend the money to reach 30 50% energy savings. Quality of retrofit work is significantly variable among contractors which impact the potential energy savings of the retrofit. Challenges exist in defining house volume and floor area. Of the five homes that completed all the recommended retrofits, energy bill savings was not the main driver for energy retrofits. In no case were the retrofits cost neutral given a 15 year loan at 7% interest for the retrofit costs.

  10. Existing Commercial Reference Buildings Constructed Before 1980 — Archive

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary of building types and...

  11. Building America Case Study: Excavationless Exterior-Side Foundation Insulation for Existing Homes, Minneapolis, Minnesota (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Excavationless: Exterior-Side Foundation Insulation for Existing Homes Minneapolis, Minnesota PROJECT INFORMATION Project Name: Excavationless Exterior Foundation Insulation Field Study Location: Minneapolis, MN Partners: Cocoon, cocoon-solutions.com Urban Homeworks, urbanhomeworks.org/ BASF, basf.us American Environmental, LLC NorthernSTAR Building America Partnership Building Component: Foundation insulation Application: Retrofit; single-family Year Tested: 2013 Applicable Climate Zones: All

  12. Geothermal Retrofit of Illinois National Guard's State headquarters Building

    SciTech Connect (OSTI)

    Lee, Mark

    2015-04-27

    The goal of this project was to assess the feasibility of utilizing mine water as a heat sink for a geothermal heat pump system to heat and cool the 74,000 sq. ft. Illinois National Guard State Headquarters’ building in Springfield Illinois. If successful, this type of system would be less expensive to install than a traditional closed loop geothermal (ground source) heat pump system by significantly reducing the size of the well field, thus shortening or eliminate the payback period compared to a conventional system. In the end, a conventional ground loop was used for the project.

  13. Existing Commercial Reference Buildings Constructed In or After 1980 |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy In or After 1980 Existing Commercial Reference Buildings Constructed In or After 1980 The files on this page contain commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. These U.S. Department of Energy (DOE) reference buildings are complete descriptions for whole building energy analysis. You can also return to a summary of building types and climate zones and information about other building

  14. Residential Retrofit Program Design Guide

    Broader source: Energy.gov [DOE]

    This Residential Retrofit Program Design Guide focuses on the key elements and design characteristics of building and maintaining a successful residential retrofit program.

  15. Sustainability in Existing Federal Buildings | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Facilities » Sustainable Buildings & Campuses » Sustainability in Existing Federal Buildings Sustainability in Existing Federal Buildings The General Services Administration renovated this historic building to meet zero energy goals. Read the <a href="/node/978261">case study</a>. The General Services Administration renovated this historic building to meet zero energy goals. Read the case study. The Guiding Principles require existing federal buildings to be

  16. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building America Technology Solutions for New and Existing Homes: Low-Load Space-Conditioning Needs Assessment, Northeast and Mid-Atlantic Building America Technology Solutions for...

  17. Existing Whole-House Solutions Case Study: Deep Energy Retrofit of 1910 House, Portland, Oregon

    SciTech Connect (OSTI)

    none,

    2011-12-01

    This case study lists project information, cost and energy efficiency performance data, energy efficiency measures and lessons learned for a 100-year-old home in Portland, Oregon, audited by Pacific Northwest National Laboratory for a deep energy retrofit. New HVAC and extensive insulation upgrades including rigid XPS and new siding over the old lead painted siding, and EPS on the basement walls and in cathedral ceiling helped bring HERS down to 68.

  18. Existing Whole-House Solutions Case Study: Retrofit of 1915 Home, Dayton, Washington

    SciTech Connect (OSTI)

    none,

    2011-12-01

    This case study lists project information, cost and energy efficiency performance data, energy efficiency measures and lessons learned for a 1915 home in eastern Washington audited by Pacific Northwest National Laboratory for an energy retrofit. The asbestos covered diesel boiler was left in place in the basement and a new SEER 16, HSPF 9.4 ductless heat pump with four inside heads was added to cut energy costs over $2,000/year.

  19. Greenbelt Homes Pilot Program. Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings

    SciTech Connect (OSTI)

    Wiehagen, J.; Del Bianco, M.; Mallay, D.

    2015-05-22

    The U.S. Department of Energy Building America team Partnership for Home Innovation wrote a report on Phase 1 of the project that summarized a condition assessment of the homes and evaluated retrofit options within the constraints of the cooperative provided by GHI. Phase 2 was completed following monitoring in the 20132014 winter season; the results are summarized in this report. Phase 3 upgrades of heating equipment will be implemented in time for the 20142015 heating season and are not part of this report.

  20. Renewable Energy Applications for Existing Buildings: Preprint

    SciTech Connect (OSTI)

    Hayter, S. J.; Kandt, A.

    2011-08-01

    This paper introduces technical opportunities, means, and methods for incorporating renewable energy (RE) technologies into building designs and operations. It provides an overview of RE resources and available technologies used successfully to offset building electrical and thermal energy loads. Methods for applying these technologies in buildings and the role of building energy efficiency in successful RE projects are addressed along with tips for implementing successful RE projects.

  1. The Retrofit Challenge: Master Specification for Affordable Housing Renovation Programs

    Energy Savers [EERE]

    Retrofit Challenge: Master Specifications for Affordable Housing Renovation Programs Hot Humid Climate - Zones 1, 2, and 3 Janet McIlvaine Florida Solar Energy Center Research Institute of the University of Central Florida Building America Partnership for Improved Residential Construction Context Building America Partnership for Improved Residential Construction Hot-Humid Climate Zone Existing Homes Research Take the Retrofit Challenge! www.ba-pirc.org/retrofit Context * 2009 - BA-PIRC expanded

  2. Building America Whole-House Solutions for Existing Homes: Multifamily...

    Office of Environmental Management (EM)

    Existing Homes: Multifamily Individual Heating and Ventilation Systems Building America Whole-House Solutions for Existing Homes: Multifamily Individual Heating and Ventilation...

  3. Building America Efficient Solutions for Existing Homes Case...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Efficient Solutions for Existing Homes Case Study: Habitat for Humanity of Palm Beach County, Lake Worth, Florida Building America Efficient Solutions for Existing Homes Case ...

  4. Building America Technology Solutions for New and Existing Homes: Balancing

    Energy Savers [EERE]

    Hydronic Systems in Multifamily Buildings, Chicago, Illinois (Fact Sheet) | Department of Energy Balancing Hydronic Systems in Multifamily Buildings, Chicago, Illinois (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Balancing Hydronic Systems in Multifamily Buildings, Chicago, Illinois (Fact Sheet) In multifamily building hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water

  5. Building America Analysis – Existing Homes

    Broader source: Energy.gov [DOE]

    The Building America Analysis Spreadsheets are companions to the House Simulation Protocols, and can assist with many of the calculations and look-up tables found in the report.

  6. Building America Technology Solutions for New and Existing Homes: Boiler

    Energy Savers [EERE]

    Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts | Department of Energy Boiler Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts Building America Technology Solutions for New and Existing Homes: Boiler Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts The ARIES Collaborative partnered with Homeowners' Rehab Inc., a nonprofit affordable housing owner, to upgrade the

  7. Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Replacing Resistance Heating with Mini-Split Heat Pumps Sharon, Connecticut PROJECT INFORMATION Project Name: Sharon Ridge Apartments Location: Sharon, CT Partners: Sharon Housing Authority, www.sharonct.org/ Advanced Residential Integrated Solutions Collaborative (ARIES), http://levypartnership.com/ Building Component: HVAC Application: Retrofit, single, or multifamily Year Tested: 2012-2013 Applicable Climate Zone(s): Mixed-humid and cold PERFORMANCE DATA Cost of energy efficiency measure

  8. Steam System Balancing and Tuning for Multifamily Residential Buildings, Chicago, Illinois (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    Steam System Balancing and Tuning for Multifamily Residential Buildings Chicago, Illinois PROJECT INFORMATION Project Name: Steam System Balancing and Tuning for Multifamily Residential Buildings Location: Chicago, IL Partners: Partnership for Advanced Residential Retrofit www.gastechnology.org Building Component: Steam heating distribution system and controls Application: Retrofit; Multifamily Year Tested: 2011-2012 Applicable Climate Zone(s): Cold humid continental PERFORMANCE DATA Cost of

  9. Review of Prior Commercial Building Energy Efficiency Retrofit Evaluation: A Report to Snohomish Public Utilities District

    SciTech Connect (OSTI)

    Price, Phillip

    2014-12-22

    Snohomish County Public Utilities District (the District or Snohomish PUD) provides electricity to about 325,000 customers in Snohomish County, Washington. The District has an incentive programs to encourage commercial customers to improve energy efficiency: the District partially reimburses the cost of approved retrofits if they provide a level of energy performance improvement that is specified by contract. In 2013 the District contracted with Lawrence Berkeley National Laboratory to provide a third-party review of the Monitoring and Verification (M&V) practices the District uses to evaluate whether companies are meeting their contractual obligations. This work helps LBNL understand the challenges faced by real-world practitioners of M&V of energy savings, and builds on a body of related work such as Price et al. (2013). The District selected a typical project for which they had already performed an evaluation. The present report includes the District's original evaluation as well as LBNL's review of their approach. The review is based on the document itself; on investigation of the load data and outdoor air temperature data from the building evaluated in the document; and on phone discussions with Bill Harris of the Snohomish County Public Utilities District. We will call the building studied in the document the subject building, the original Snohomish PUD report will be referred to as the Evaluation, and this discussion by LBNL is called the Review.

  10. Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring

    SciTech Connect (OSTI)

    Dentz, J.; Henderson, H.; Varshney, K.

    2014-09-01

    The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

  11. Thermal and moisture problems in existing basements create a...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    quality, affordability, and comfort. DOEGO-102015-4567 * April 2015 BUILDING AMERICA CASE STUDY: TECHNOLOGY SOLUTIONS FOR NEW AND EXISTING HOMES Interior Basement Retrofit Wall...

  12. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Calculating Design Heating Loads for Superinsulated Buildings | Department of Energy Calculating Design Heating Loads for Superinsulated Buildings Building America Technology Solutions for New and Existing Homes: Calculating Design Heating Loads for Superinsulated Buildings During the winter of 2013-2014, the Consortium for Advanced Residential Buildings monitored the energy use of three homes in the EcoVillage community in climate zone 6 to evaluate the accuracy of two different mechanical

  13. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cladding Attachment Over Mineral Fiber Insulation Board - Ontario, Canada Building America Technology Solutions for New and Existing Homes: Cladding Attachment Over Mineral Fiber ...

  14. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building America Technology Solutions for New and Existing Homes: Investigating Solutions to Wind Washing Issues in Two-Story Florida Homes: Phase 2, Southeastern United States...

  15. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Replacing Resistance Heating with Mini-Split Heat Pumps Building America Technology Solutions for New and Existing Homes: Replacing Resistance Heating with Mini-Split Heat Pumps In ...

  16. Building America Technlogy Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building America Technlogy Solutions for New and Existing Homes: Improving the Field ... that common installation practices and age-induced equipment degradation may have on ...

  17. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building America Technology Solutions for New and Existing Homes: Calculating Design ... monitored the energy use of three homes in the EcoVillage community in climate ...

  18. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Technology Solutions for New Manufactured Homes - Washington, Oregon, and Idaho Building America Technology Solutions for New and Existing Homes: Technology Solutions for New ...

  19. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Project Overcoat: Airtightness Strategies and Impacts for 1 12-Story Homes, Minneapolis, Minnesota Building America Technology Solutions for New and Existing Homes: Project ...

  20. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Investigating Solutions to Wind Washing Issues in Two-Story Florida Homes: Phase 2, Southeastern United States Building America Technology Solutions for New and Existing Homes: ...

  1. Building America Efficient Solutions for Existing Homes Case...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Habitat for Humanity South Sarasota County, Venice, Florida Building America Efficient Solutions for Existing Homes Case Study: Habitat for Humanity South Sarasota County, Venice, ...

  2. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Predicting Envelope Leakage in Attached Dwellings (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Predicting Envelope Leakage in Attached Dwellings ...

  3. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Performance of ...

  4. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Technology Solutions for New and Existing Homes: Advanced Controls Improve Performance of Combination Space- and Water-Heating Systems Building America Technology Solutions for New ...

  5. Building America Whole-House Solutions for Existing Homes: Islip...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Efficient Manufactured Housing Program High-Performance Test Homes Building America Whole-House Solutions for Existing Homes: Passive Room-to-Room Air Transfer, Fresno...

  6. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Replacing Resistance Heating with Mini-Split Heat Pumps Building America Technology Solutions for New and Existing Homes: Replacing Resistance Heating with Mini-Split Heat Pumps In...

  7. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Apartment Compartmentalization with an Aerosol-Based Sealing Process Building America Technology Solutions for New and Existing Homes: Apartment Compartmentalization with an...

  8. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building America Technology Solutions for New and Existing Homes: Cold Climate Foundation Wall Hygrothermal Research Facility (Fact Sheet) This case study describes the University ...

  9. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building America Technology Solutions for New and Existing Homes: Ground Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia (Fact Sheet), This case study describes ...

  10. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    icon Moisture Management of High-R Walls More Documents & Publications Building America Technology Solutions for New and Existing Homes: Monitoring of Double-Stud Wall Moisture...

  11. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Air Conditioner Installation for Efficiency and Comfort (Fact Sheet) Building America Technology Solutions for New and Existing Homes: A Homeowner's Guide to Window Air...

  12. Business Energy Efficiency Rebate for Existing Buildings | Department...

    Broader source: Energy.gov (indexed) [DOE]

    institutional customers of any of the state's investor owned utilities to increase the energy efficiency of their existing buildings. The standard incentive program provides...

  13. Building America Technology Solutions for New and Existing Homes...

    Energy Savers [EERE]

    Building America Technology Solutions for New and Existing Homes: Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet) In addition...

  14. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Boiler Load Monitoring Controllers, Chicago, Illinois Building America Technology Solutions for New and Existing Homes: Advanced Boiler Load Monitoring Controllers, Chicago, ...

  15. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Monitoring of Double-Stud Wall Moisture Conditions in the Northeast, Devens, Massachusetts Building America Technology Solutions for New and Existing Homes: Monitoring of ...

  16. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Replacement, Variable-Speed Motors for Furnaces, Syracuse, New York, (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Replacement, Variable-Speed ...

  17. Existing Homes Retrofit Case Study: SMUD's Energy Efficient Remodel Demonstration Project: Sacramento, CA

    SciTech Connect (OSTI)

    2010-10-01

    Sacramento Municipal Utility District (SMUD) worked with DOE's Building America Program to cut energy use by more than 50% in a rehab of a 1950s tract home in Sacramento.

  18. Building Energy Simulation Test for Existing Homes (BESTEST-EX); Phase 1 Test Procedure: Building Thermal Fabric Cases

    SciTech Connect (OSTI)

    Judkoff, Ron

    2010-08-01

    This report documents the initial Phase 1 test process for testing the reliability of software models that predict retrofit energy savings of existing homes, including their associated calibration methods.

  19. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Excavationless: Exterior-Side Foundation Insulation for Existing Homes (Fact Sheet) | Department of Energy Excavationless: Exterior-Side Foundation Insulation for Existing Homes (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Excavationless: Exterior-Side Foundation Insulation for Existing Homes (Fact Sheet) Building science research supports installing exterior (soil side) foundation insulation as the optimal method to enhance the hygrothermal performance of

  20. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Optimizing Hydronic System Performance in Residential Applications (Fact Sheet) | Department of Energy Technology Solutions for New and Existing Homes: Optimizing Hydronic System Performance in Residential Applications (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Optimizing Hydronic System Performance in Residential Applications (Fact Sheet) In this project, researchers from the Consortium for Advanced Residential Buildings team worked with industry partners

  1. Building America Technology Solutions for New and Existing Homes: Air

    Energy Savers [EERE]

    Leakage and Air Transfer Between Garage and Living Space | Department of Energy Building America Technology Solutions for New and Existing Homes: Air Leakage and Air Transfer Between Garage and Living Space Building America Technology Solutions for New and Existing Homes: Air Leakage and Air Transfer Between Garage and Living Space In this project, Building Science Corporation worked with production home builder K. Hovnanian to conduct testing at a single-family home in Waldorf, Maryland,

  2. Building America Webinar: Solutions for Combustion Safety in Existing Homes

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    | Department of Energy Building America Webinar: Solutions for Combustion Safety in Existing Homes Building America Webinar: Solutions for Combustion Safety in Existing Homes December 16, 2015 3:00PM to 4:30PM EST It is often challenging for residential contractors to conduct appropriate combustion safety test procedures in existing homes and use effective actions to address any failures. Commonly used testing methods can be complicated to follow and may be overly conservative, producing

  3. Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings

    Broader source: Energy.gov [DOE]

    This webinar will focus on improving the performance of central space conditioning systems in multifamily buildings. Presenters will discuss hydronic heating strategies and the evaluation of thermostatically controlled radiator valves (TRVs).

  4. Building America Best Practices Series, Vol. 10 - Retrofit Techniques & Technologies: Air Sealing, A Guide for Contractors to Share with Homeowners

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    TECHNOLOGIES PROGRAM R Retrofit Techniques & Technologies: Air Sealing A Guide for Contractors to Share with Homeowners PREPARED BY Pacific Northwest National Laboratory & Oak Ridge National Laboratory April 12, 2010 April 12, 2010 * PNNL-19284 BUILDING AMERICA BEST PRACTICES SERIES VOLUME 10. BuiLDiNG AmERiCA BEST PRACTiCES SERiES Retrofit Techniques and Technologies: Air Sealing A Guide for Contractors to Share with Homeowners PREPARED BY Pacific Northwest National Laboratory michael

  5. Building America Technology Solutions for New and Existing Homes...

    Broader source: Energy.gov (indexed) [DOE]

    Residential Retrofit team provides guidance on how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for...

  6. Building America Whole-House Solutions for Existing Homes: Exterior...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Research and Development Authority to research exterior wall insulation solutions for enclosure upgrades. This case study describes the deep energy retrofit of three test ...

  7. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    balancing valves, inefficient water temperature and flow levels, and owneroccupant ... In this case study , Partnership for Advanced Residential Retrofit and Elevate Energy. ...

  8. Strategy Guideline. Application of a Construction Quality Process to Existing Home Retrofits

    SciTech Connect (OSTI)

    Mallay, D.; Del Bianco, M.

    2013-08-01

    The Partnership for Home Innovation developed a construction quality process for new and existing high performance homes (HPH) in which high performance goals are established, specifications to meet those goals are defined, and construction monitoring points are added to the construction schedule so that critical energy efficiency details are systematically reviewed, documented, and tested in a timely manner. This report follows the evolution of the construction quality process from its development for new homes, to its application in the construction of a high performance home with enhanced specifications, and its application in a crawlspace renovation.

  9. Strategy Guideline: Application of a Construction Quality Process to Existing Home Retrofits

    SciTech Connect (OSTI)

    Mallay, D.; Del Bianco, M.

    2013-08-01

    The Home Innovation Research Labs developed a construction quality process for new and existing high performance homes (HPH) in which high performance goals are established, specifications to meet those goals are defined, and construction monitoring points are added to the construction schedule so that critical energy efficiency details are systematically reviewed, documented, and tested in a timely manner. This report follows the evolution of the construction quality process from its development for new homes, to its application in the construction of a high performance home with enhanced specifications, and its application in a crawlspace renovation.

  10. New York City- Energy Conservation Requirements for Existing Buildings

    Broader source: Energy.gov [DOE]

    Council Bill No. 564-A (Local Law 85 of 2009): Requires that renovations of existing buildings meet minimum energy conservation standards. The result of this law is essentially a city energy code ...

  11. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Long-Term Monitoring of Mini-Split Ductless Heat Pumps in the Northeast, Devens and ... Building America Technology Solutions for New and Existing Homes: Long-Term Monitoring of ...

  12. Building America Technology Solutions for New and Existing Homes:

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Optimizing Hydronic System Performance in Residential Applications, Ithaca, New York (Fact Sheet) | Department of Energy Optimizing Hydronic System Performance in Residential Applications, Ithaca, New York (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Optimizing Hydronic System Performance in Residential Applications, Ithaca, New York (Fact Sheet) In this project, researchers from Building America team Consortium for Advanced Residential Buildings worked with

  13. Building America Technology Solutions for New and Existing Homes Case

    Energy Savers [EERE]

    Study: Field Testing an Unvented Roof with Fibrous Insulation and Tiles | Department of Energy Homes Case Study: Field Testing an Unvented Roof with Fibrous Insulation and Tiles Building America Technology Solutions for New and Existing Homes Case Study: Field Testing an Unvented Roof with Fibrous Insulation and Tiles This case study by the U.S. Department of Energy's Building America research team Building Science Corporation is a test implementation of an unvented tile roof assembly in a

  14. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Hygrothermal Performance of a Double-Stud Cellulose Wall, Devens, Massachusetts | Department of Energy Hygrothermal Performance of a Double-Stud Cellulose Wall, Devens, Massachusetts Building America Technology Solutions for New and Existing Homes: Hygrothermal Performance of a Double-Stud Cellulose Wall, Devens, Massachusetts In this project, the Building America research team Consortium for Advanced Residential Buildings monitored a double-stud assembly in climate zone 5A to determine the

  15. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet) | Department of Energy Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet) For a 6-month period, the Building America team Consortium for Advanced Residential Buildings monitored the

  16. Building America Technology Solutions for New and Existing Homes: Apartment

    Energy Savers [EERE]

    Compartmentalization with an Aerosol-Based Sealing Process | Department of Energy Apartment Compartmentalization with an Aerosol-Based Sealing Process Building America Technology Solutions for New and Existing Homes: Apartment Compartmentalization with an Aerosol-Based Sealing Process In this study, the Consortium for Advanced Residential Buildings team demonstrated the automated air sealing and compartmentalization of buildings through the use of an aerosolized sealant developed by the

  17. Building America Technology Solutions for New and Existing Homes: Buried

    Energy Savers [EERE]

    and Encapsulated Ducts, Jacksonville, Florida (Fact Sheet) | Department of Energy Buried and Encapsulated Ducts, Jacksonville, Florida (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Buried and Encapsulated Ducts, Jacksonville, Florida (Fact Sheet) In a study of three single-story houses in Florida, the Building America research team Consortium for Advanced Residential Buildings (CARB) investigated the strategy of using buried and/or encapsulated ducts to

  18. Building America Technology Solutions for New and Existing Homes: Cladding

    Energy Savers [EERE]

    Attachment Over Thick Exterior Insulating Sheathing (Fact Sheet) | Department of Energy Cladding Attachment Over Thick Exterior Insulating Sheathing (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Cladding Attachment Over Thick Exterior Insulating Sheathing (Fact Sheet) In this project, researchers from Building Science Corporation investigated issues to better understand the mechanics behind the addition of insulation to the exterior of buildings to increase

  19. Building America Technology Solutions for New and Existing Homes: Moisture

    Energy Savers [EERE]

    Management of High-R Walls | Department of Energy Management of High-R Walls Building America Technology Solutions for New and Existing Homes: Moisture Management of High-R Walls This project by Building Science Corporation focuses on how eight high-R walls handle the three main sources of moisture-construction moisture, air leakage condensation, and bulk water leaks. PDF icon Moisture Management of High-R Walls More Documents & Publications Building America Technology Solutions for New

  20. Building America Technology Solutions for New and Existing Homes:

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana | Department of Energy Building America Technology Solutions for New and Existing Homes: Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana Building America Technology Solutions for New and Existing Homes: Evaluation of the Performance of Houses With and Without Supplemental

  1. Building America Technology Solutions for Existing Homes: Initial and

    Energy Savers [EERE]

    Long-Term Cladding Over Exterior Insulation | Department of Energy Existing Homes: Initial and Long-Term Cladding Over Exterior Insulation Building America Technology Solutions for Existing Homes: Initial and Long-Term Cladding Over Exterior Insulation This research conducted by Building Science Corporation evaluated the system mechanics and long-term performance of the use of wood furring strips attached through the insulation back to the structure to provide a convenient cladding

  2. Building America Technology Solutions for New and Existing Homes: New

    Energy Savers [EERE]

    Insights for Improving the Designs of Flexible Duct Junction Boxes (Fact Sheet) | Department of Energy Building America Technology Solutions for New and Existing Homes: New Insights for Improving the Designs of Flexible Duct Junction Boxes (Fact Sheet) Building America Technology Solutions for New and Existing Homes: New Insights for Improving the Designs of Flexible Duct Junction Boxes (Fact Sheet) IBACOS explored the relationships between pressure and physical configurations of flexible

  3. Building America Whole-House Solutions for Existing Homes: Passive

    Energy Savers [EERE]

    Room-to-Room Air Transfer, Fresno, California (Fact Sheet) | Department of Energy Whole-House Solutions for Existing Homes: Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet) Building America Whole-House Solutions for Existing Homes: Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet) In this project, IBACOS, a U.S. Department of Energy Building America team, assessed a strategy for providing conditioned air to bedrooms when the bedroom doors are closed and

  4. Building America Performance Analysis Procedures for Existing Homes

    SciTech Connect (OSTI)

    2006-05-01

    Building America is investigating the best ways to make existing homes more energy-efficient, based on lessons learned from research in new homes. America program is aiming for a 20%30% reduction in energy use in existing homes by 2020.

  5. Hydronic Heating Retrofits for Low-Rise Multifamily Buildings and Thermostatic Radiator Valve Evaluation

    Energy Savers [EERE]

    Focusing on affordable housing including new and existing multifamily buildings WHY IS THIS IMPORTANT?  ~14 million units in the U.S. use steam or hot water heating  Space heating the largest energy use in mixed and cold climate buildings  Overheating study found nearly all apartments overheated most of the time: average heating season temp. 76.2°F Long-term temperature data from ~100 apartments in 18 buildings:  Almost all apartments overheated most of the time  Average heating

  6. Building America Webinar: Low-E Storms: The Next Big Thing in Window Retrofits

    Broader source: Energy.gov [DOE]

    Until recently, energy-efficient window retrofit options have largely been limited to repair or replacement; leaving the homeowner to decide between affordability and deeper energy savings. A new...

  7. Building America Case Studies for Existing Homes: Philadelphia Housing

    Energy Savers [EERE]

    Authority Energy-Efficiency Turnover Protocols | Department of Energy Philadelphia Housing Authority Energy-Efficiency Turnover Protocols Building America Case Studies for Existing Homes: Philadelphia Housing Authority Energy-Efficiency Turnover Protocols The Philadelphia Housing Authority worked with the U.S. Department of Energy's Building America Program to integrate energy-efficiency measures into the refurbishment process that each unit normally goes through between occupancies. PDF

  8. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Application of Spray Foam Insulation Under Plywood and OSB Roof Sheathing (Fact Sheet) | Department of Energy Application of Spray Foam Insulation Under Plywood and OSB Roof Sheathing (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Application of Spray Foam Insulation Under Plywood and OSB Roof Sheathing (Fact Sheet) This case study describes Building Science Corporation's research into spray polyurethane foams in residential roofs, performing hygrothermal

  9. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Investigating Solutions to Wind Washing Issues in Two-Story Florida Homes: Phase 2, Southeastern United States | Department of Energy Investigating Solutions to Wind Washing Issues in Two-Story Florida Homes: Phase 2, Southeastern United States Building America Technology Solutions for New and Existing Homes: Investigating Solutions to Wind Washing Issues in Two-Story Florida Homes: Phase 2, Southeastern United States In this project, the Building America Partnership for Improved Residential

  10. Building America Technology Solutions for New and Existing Homes: Advanced

    Energy Savers [EERE]

    Controls Improve Performance of Combination Space- and Water-Heating Systems | Department of Energy Controls Improve Performance of Combination Space- and Water-Heating Systems Building America Technology Solutions for New and Existing Homes: Advanced Controls Improve Performance of Combination Space- and Water-Heating Systems In this project, NorthernSTAR Building America Partnership team demonstrated improved controls have the potential to reduce complexity of combination systems and boost

  11. Building America Technology Solutions for New and Existing Homes: Capillary

    Energy Savers [EERE]

    Break Beneath a Slab: Polyethylene Sheeting over Aggregate, Southwestern Pennsylvania (Fact Sheet) | Department of Energy Capillary Break Beneath a Slab: Polyethylene Sheeting over Aggregate, Southwestern Pennsylvania (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Capillary Break Beneath a Slab: Polyethylene Sheeting over Aggregate, Southwestern Pennsylvania (Fact Sheet) In this project, Building America team IBACOS worked with a builder of single- and

  12. Building America Technology Solutions for New and Existing Homes: Cold

    Energy Savers [EERE]

    Climate Foundation Wall Hygrothermal Research Facility (Fact Sheet) | Department of Energy Cold Climate Foundation Wall Hygrothermal Research Facility (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Cold Climate Foundation Wall Hygrothermal Research Facility (Fact Sheet) This case study describes the University of Minnesota's Cloquet Residential Research Facility (CRRF) in northern Minnesota, which features more than 2,500 ft2 of below-grade space for building

  13. Building America Technology Solutions for New and Existing Homes: Duct

    Energy Savers [EERE]

    Sealing Using Injected Spray Sealant | Department of Energy Sealing Using Injected Spray Sealant Building America Technology Solutions for New and Existing Homes: Duct Sealing Using Injected Spray Sealant In this project, the Raleigh Housing Authority worked with Building America team, the Advanced Residential Integrated Solutions Collaborative, to determine the most cost-effective ways to reduce duct leakage in its low-rise housing units. PDF icon Ducts Sealing Using Injected Spray Sealant

  14. Building America Technology Solutions for New and Existing Homes: Project

    Energy Savers [EERE]

    Overcoat: Airtightness Strategies and Impacts for 1 1/2-Story Homes, Minneapolis, Minnesota | Department of Energy Project Overcoat: Airtightness Strategies and Impacts for 1 1/2-Story Homes, Minneapolis, Minnesota Building America Technology Solutions for New and Existing Homes: Project Overcoat: Airtightness Strategies and Impacts for 1 1/2-Story Homes, Minneapolis, Minnesota In this project, the NorthernSTAR Building America Partnership team studied the effectiveness of the External

  15. Building America Efficient Solutions for Existing Homes Case...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    siding, and EPS on the basement walls and in cathedral ceiling helped bring HERS down to 68. PDF icon Case Study: Deep Energy Retrofit of 1910 House - Portland, Oregon More ...

  16. Existing Whole-House Solutions Case Study: Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit, Annapolis, Maryland

    SciTech Connect (OSTI)

    2013-10-01

    Under this project, the BA-PIRC research team evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place deep energy retrofit at the Bay Ridge multifamily development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This case study summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete.

  17. Combustion Safety for Appliances Using Indoor Air (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Combustion Safety for Appliances Using Indoor Air PROJECT INFORMATION Project Name: Combustion Safety for Appliances Using Indoor Air Partners: American Gas Association www.aga.org Center of Energy and Environment www.mncee.org Building Performance Institute www.bpi.org NorthernSTAR Building America Partnership Partnership for Advanced Residential Retrofit www.gastechnology.org/PARR Building Components: Gas Appliances Application: Retrofit Single Family Year Tested: 2013 Applicable Climate

  18. Building America Efficient Solutions for Existing Homes Case Study: Habitat

    Energy Savers [EERE]

    for Humanity of Palm Beach County, Lake Worth, Florida | Department of Energy Efficient Solutions for Existing Homes Case Study: Habitat for Humanity of Palm Beach County, Lake Worth, Florida Building America Efficient Solutions for Existing Homes Case Study: Habitat for Humanity of Palm Beach County, Lake Worth, Florida PNNL and Florida Solar Energy Center worked with Habitat for Humanity of Palm Beach County to upgrade an empty 1996 home with a 14.5 SEER AC, heat pump water heater, CFLs,

  19. Building America Technology Solutions for New and Existing Homes: Field

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Testing of Compartmentalization Methods for Multifamily Construction | Department of Energy Field Testing of Compartmentalization Methods for Multifamily Construction Building America Technology Solutions for New and Existing Homes: Field Testing of Compartmentalization Methods for Multifamily Construction Fire-resistance rated (or area separation) wall assemblies present a great difficulty in air sealing/compartmentalization, particularly in townhouse construction. To address this

  20. Building America Technlogy Solutions for New and Existing Homes: Interior

    Energy Savers [EERE]

    Foundation Insulation Upgrade - Minneapolis Residence (Fact Sheet) | Department of Energy Minneapolis Residence (Fact Sheet) Building America Technlogy Solutions for New and Existing Homes: Interior Foundation Insulation Upgrade - Minneapolis Residence (Fact Sheet) This interior foundation project employed several techniques to improve performance and mitigate moisture issues: dimple mat; spray polyurethane foam insulation; moisture and thermal management systems for the floor; and paperless

  1. Existing Whole-House Solutions Case Study: Build San Antonio Green, San Antonio, Texas

    SciTech Connect (OSTI)

    none,

    2013-06-01

    PNNL, FSEC, and CalcsPlus provided technical assistance to Build San Antonio Green on three deep energy retrofits. For this gut rehab they replaced the old roof with a steeper roof and replaced drywall while adding insulation, new HVAC, sealed ducts, transfer grilles, outside air run-time ventilation, new lighting and water heater.

  2. Building America Case Studies for Existing Homes: Supplemental Ductless

    Energy Savers [EERE]

    Mini-Split Heat Pump in the Hot-Humid Climate | Department of Energy Supplemental Ductless Mini-Split Heat Pump in the Hot-Humid Climate Building America Case Studies for Existing Homes: Supplemental Ductless Mini-Split Heat Pump in the Hot-Humid Climate The Building America Partnership for Improved Residential Construction team that studied the effects of mini-split heat pumps in six central Florida homes. PDF icon Supplemental Ductless Mini-Split Heat Pump in the Hot-Humid Climate More

  3. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Air-to-Water Heat Pumps with Radiant Delivery in Low Load Homes (Fact Sheet) | Department of Energy Air-to-Water Heat Pumps with Radiant Delivery in Low Load Homes (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Air-to-Water Heat Pumps with Radiant Delivery in Low Load Homes (Fact Sheet) Researchers from Alliance for Residential Building Initiative worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump

  4. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    High-Performance Walls in Hot-Dry Climates | Department of Energy High-Performance Walls in Hot-Dry Climates Building America Technology Solutions for New and Existing Homes: High-Performance Walls in Hot-Dry Climates In this project,the Alliance for Residential Building Innovation team worked with builders in California to implement wall assemblies meeting a U-value lower than 0.050 Btu/h-ft2-°F. ARBI and its project team members helped builders identify preferred wall designs that met the

  5. High-Efficiency Retrofit Lessons for Retail from a SuperTarget: Preprint

    SciTech Connect (OSTI)

    Langner, R.; Deru, M.; Hirsch, A.; Williams, S.

    2013-02-01

    The National Renewable Energy Laboratory partnered with Target under the Commercial Building Program to design and implement a retrofit of a SuperTarget in Thornton, CO. The result was a retrofit design that predicted 37% energy savings over ASHRAE Standard 90.1-2004, and 29% compared to existing (pre-retrofit) store consumption. The largest savings came from energy efficient lighting, energy efficient cooling systems, improved refrigeration, and better control of plug loads.

  6. Chamberlain Heights Redevelopment: A Large Scale, Cold Climate Study of Affordable Housing Retrofits

    SciTech Connect (OSTI)

    Donnelly, K.; Mahle, M.

    2012-03-01

    The City of Meriden Housing Authority (MHA) collaborated with affordable housing developer Jonathon Rose Companies (JRC) to complete a gut renovation of 124 residential units in the Chamberlain Heights retrofit project. The affordable housing community is made up of 36 buildings in duplex and quad configurations located on 22 acres within two miles of downtown Meriden, CT. The final post-retrofit analysis showed 40%-45% source energy savings over the existing pre-retrofit conditions.

  7. Chamberlain Heights Redevelopment: A Large Scale, Cold Climate Study of Affordable Housing Retrofits

    SciTech Connect (OSTI)

    Donnelly, K.; Mahle, M.

    2012-03-01

    The City of Meriden Housing Authority (MHA) collaborated with affordable housing developer Jonathon Rose Companies (JRC) to complete a gut renovation of 124 residential units in the Chamberlain Heights retrofit project. The affordable housing community is made up of 36 buildings in duplex and quad configurations located on 22 acres within two miles of downtown Meriden, CT. The final post-retrofit analysis showed 40-45% source energy savings over the existing pre-retrofit conditions.

  8. Existing Whole-House Solutions Case Study: Exterior Insulation Pre- and Post-Retrofit, Syracuse, New York

    SciTech Connect (OSTI)

    2015-05-01

    In this study, IBACOS, in collaboration with GreenHomes America, Inc., was contracted by the New York State Energy Research and Development Authority (NYSERDA) to research exterior wall insulation solutions for enclosure upgrades. This case study describes the deep energy retrofit of three test homes in the Syracuse, New York area and represent these enclosure strategies: rigid foam insulation; spray foam insulation, and a control house that follows Home Performance with ENERGY STAR (HPwES) guidelines.

  9. Building America Case Study: Balancing Hydronic Systems in Multifamily Buildings, Chicago, Illinois (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Balancing Hydronic Systems in Multifamily Buildings Chicago, Illinois PROJECT INFORMATION Location: Chicago, IL area Partners: Elevate Energy elevateenergy.org/ Partnership for Advanced Residential Retrofit gastechnology.org/PARR Building Component: HVAC Application: Multifamily Year Tested: 2014 Applicable Climate Zones: 1, 2, 3 PERFORMANCE DATA Retrofit: Booster pump to increase flow in an underheated zone Cost of energy efficiency measure (including labor): $6,330 Temperature spread decrease:

  10. Islip Housing Authority Energy Efficiency Turnover Protocols, Islip, New York (Fact Sheet), Building America Case Study: Whole-House Solutions for Existing Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    Islip Housing Authority Energy Efficiency Turnover Protocols Islip, New York PROJECT INFORMATION Project Name: Islip Housing Authority Unit Turnover Retrofit Program Location: Islip, NY Partners: Islip Housing Authority, http://www.rhaonline.com/ Advanced Residential Integrated Solutions Collaborative (ARIES), http://levypartnership.com/ Building Component: Whole building Application: Retrofit; single and multifamily Year Tested: 2013 Applicable Climate Zone(s): All PERFORMANCE DATA Cost of

  11. Building America High Performance Enclosure Strategies: Part 1, Existing Homes

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building America High Performance Enclosure Strategies: Part I, Existing Homes May 21, 2014 Moderator: Mike Gestwick- National Renewable Energy Laboratory Panelists: Tom Schirber - University of Minnesota Steve Schirber - Cocoon Insulation Anastasia Herk - IBACOS Duncan Prahl - IBACOS Some Housekeeping Items Two Options for Audio (select audio mode): 1. Listen through your computer. Please select the "mic and speakers" radio button on the right hand audio pane display 2. Listen by

  12. Building America Technlogy Solutions for New and Existing Homes: Interior

    Energy Savers [EERE]

    Foundation Insulation Upgrade - Madison Residence (Fact Sheet) | Department of Energy Madison Residence (Fact Sheet) Building America Technlogy Solutions for New and Existing Homes: Interior Foundation Insulation Upgrade - Madison Residence (Fact Sheet) This basement insulation project included a dimple map conveying inbound moisture to a draintile, airtight spray polyurethane foam wall and floor insulation, and radiant floor heat installation. PDF icon Interior Foundation Insulation

  13. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana | Department of Energy the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana Building America Technology Solutions for New and Existing Homes: Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana In this project,

  14. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Foundation Heat Exchanger, Oak Ridge, Tennessee | Department of Energy Foundation Heat Exchanger, Oak Ridge, Tennessee Building America Technology Solutions for New and Existing Homes: Foundation Heat Exchanger, Oak Ridge, Tennessee The foundation heat exchanger, developed by Oak Ridge National Laboratory, is a new concept for a cost-effective horizontal ground heat exchanger that can be connected to water-to-water or water-to-air heat pump systems for space conditioning as well as domestic

  15. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Monitoring of Double-Stud Wall Moisture Conditions in the Northeast, Devens, Massachusetts | Department of Energy Monitoring of Double-Stud Wall Moisture Conditions in the Northeast, Devens, Massachusetts Building America Technology Solutions for New and Existing Homes: Monitoring of Double-Stud Wall Moisture Conditions in the Northeast, Devens, Massachusetts Double stud walls have a higher risk of interior-sourced condensation moisture damage when compared with high-R approaches using

  16. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Predicting Envelope Leakage in Attached Dwellings (Fact Sheet) | Department of Energy Predicting Envelope Leakage in Attached Dwellings (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Predicting Envelope Leakage in Attached Dwellings (Fact Sheet) In an attempt to create a simplified tool for predicting leakage to the outside, the CARB team analyzed blower door test results from 236 attached dwelling units in 17 apartment complexes to investigate the correlation

  17. Building America Technology Solutions for New and Existing Homes:

    Energy Savers [EERE]

    Replacement, Variable-Speed Motors for Furnaces, Syracuse, New York, (Fact Sheet) | Department of Energy Replacement, Variable-Speed Motors for Furnaces, Syracuse, New York, (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Replacement, Variable-Speed Motors for Furnaces, Syracuse, New York, (Fact Sheet) In this project, the CARB team tested the Concept 3 replacement motors for residential furnaces in eight homes in and near Syracuse, New York, to test how these

  18. Building America Technology Solutions for New and Existing Homes: A

    Energy Savers [EERE]

    Homeowner's Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet) | Department of Energy A Homeowner's Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet) Building America Technology Solutions for New and Existing Homes: A Homeowner's Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet) This step-by-step guide developed by the National Renewable Energy Laboratory describes proper installation of

  19. Building America Technology Solutions for New and Existing Homes: Ground

    Energy Savers [EERE]

    Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia (Fact Sheet), | Department of Energy Ground Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia (Fact Sheet), Building America Technology Solutions for New and Existing Homes: Ground Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia (Fact Sheet), This case study describes the construction of a new test home in Atlanta, GA, that demonstrates current best practices for the mixed-humid climate,

  20. Building America Technology Solutions for New and Existing Homes: Improving

    Energy Savers [EERE]

    Comfort in Hot-Humid Climates with a Whole-House Dehumidifier, Windermere, Florida (Fact Sheet) | Department of Energy Improving Comfort in Hot-Humid Climates with a Whole-House Dehumidifier, Windermere, Florida (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Improving Comfort in Hot-Humid Climates with a Whole-House Dehumidifier, Windermere, Florida (Fact Sheet) In order to quantify the performance of a combined whole-house dehumidifier (WHD) AC system,

  1. Building America Technology Solutions for New and Existing Homes: Raised

    Energy Savers [EERE]

    Ceiling Interior Duct System, New Smyrna, Florida (Fact Sheet) | Department of Energy Raised Ceiling Interior Duct System, New Smyrna, Florida (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Raised Ceiling Interior Duct System, New Smyrna, Florida (Fact Sheet) This project describes a Habitat for Humanity builder's efforts to construct a home to new DOE Zero Energy Ready Home standards, and use a fur-up or raised ceiling chase. PDF icon Raised Ceiling Interior

  2. Building America Technology Solutions for New and Existing Homes: Stud

    Energy Savers [EERE]

    Walls With Continuous Exterior Insulation for Factory Built Housing (Fact Sheet) | Department of Energy Stud Walls With Continuous Exterior Insulation for Factory Built Housing (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Stud Walls With Continuous Exterior Insulation for Factory Built Housing (Fact Sheet) This profile describes the Advanced Envelope Research project, managed by ARIES Collaborative, which will provide factory homebuilders with high

  3. Existing Commercial Reference Buildings Constructed In or After 1980 — Archive

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location.

  4. The reHABITAT Guide: For Energy- and Resource-Efficient Retrofit Strategies

    SciTech Connect (OSTI)

    2004-07-01

    This guide seeks to advance the goal of the U.S. Department of Energys Existing Residential Buildings Program (ERBP): to develop approaches that will enable the housing retrofit industry to deliver energy-efficient housing improvements.

  5. CBEI: Lessons Learned from Integrated Retrofits in Small and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Lessons Learned from Integrated Retrofits in Small and Medium Sized Commercial Buildings - 2015 Peer Review CBEI: Lessons Learned from Integrated Retrofits in Small and Medium...

  6. EnergySmart Schools Tips: Retrofitting, Operating, and Maintaining Existing Buildings

    Broader source: Energy.gov [DOE]

    An EnergySmart Schools fact sheet that discusses quick wins and long-term facility management strategies that pay for themselves and result in energy savings.

  7. EnergySmart Schools Tips: Retrofitting, Operating, and Maintaining Existing Buildings

    SciTech Connect (OSTI)

    2009-06-01

    An EnergySmart Schools fact sheet that discusses quick wins and long-term facility management strategies that pay for themselves and result in energy savings.

  8. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    normal leakage paths through the building envelope disappear. This research effort by the Building America team, Consortium for Advanced Residential Buildings, evaluated four...

  9. Building America Technology Solutions for New and Existing Homes: Cost

    Energy Savers [EERE]

    Analysis of Roof-Only Air Sealing and Insulation Strategies on 1-1/2 Story Homes in Cold Climates, Minneapolis, MN | Department of Energy Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1-1/2 Story Homes in Cold Climates, Minneapolis, MN Building America Technology Solutions for New and Existing Homes: Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1-1/2 Story Homes in Cold Climates, Minneapolis, MN This case study describes the External Thermal and

  10. Evaluation of Retrofit Delivery Packages

    SciTech Connect (OSTI)

    Berman, M.; Smith, P.; Porse, E.

    2013-07-01

    Residential energy retrofit activities are a critical component of efforts to increase energy efficiency in the U.S. building stock; however, retrofits account for a small percentage of aggregate energy savings at relatively high per unit costs. This report by Building America research team, Alliance for Residential Building Innovation (ARBI), describes barriers to widespread retrofits and evaluates opportunities to improve delivery of home retrofit measures by identifying economies of scale in marketing, energy assessments, and bulk purchasing through pilot programs in portions of Sonoma, Los Angeles, and San Joaquin Counties, CA. These targeted communities show potential and have revealed key strategies for program design, as outlined in the report.

  11. Chapter 8, Whole-Building Retrofit with Billing Analysis Evaluation Protocol: The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    8: Whole-Building Retrofit with Consumption Data Analysis Evaluation Protocol Ken Agnew and Mimi Goldberg, DNV KEMA Subcontract Report NREL/SR-7A30-53827 April 2013 The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures 8 - 1 Chapter 8 - Table of Contents 1 Measure Description ...............................................................................................................2 2 Application Conditions of Protocol

  12. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    This guide, developed by Consortium for Advanced Residential Buildings, provides ... Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts

  13. Hungary-Employment Impacts of a Large-Scale Deep Building Retrofit...

    Open Energy Info (EERE)

    AgencyCompany Organization European Climate Foundation Sector Energy Focus Area Energy Efficiency, Buildings, - Building Energy Efficiency Topics Co-benefits assessment,...

  14. Building America Technology Solutions for New and Existing Homes: Selecting Ventilation Systems for Existing Homes

    Broader source: Energy.gov [DOE]

    This research effort by the Building America team, Consortium for Advanced Residential Buildings, evaluated four different strategies for provide make-up air to multifamily residential buildings, which included several weeks of building pressure monitoring.

  15. Multifamily Ventilation Retrofit Strategies

    SciTech Connect (OSTI)

    Ueno, K.; Lstiburek, J.; Bergey, D.

    2012-12-01

    In multifamily buildings, central ventilation systems often have poor performance, overventilating some portions of the building (causing excess energy use), while simultaneously underventilating other portions (causing diminished indoor air quality). BSC and Innova Services Corporation performed a series of field tests at a mid-rise test building undergoing a major energy audit and retrofit, which included ventilation system upgrades.

  16. Training on Multifamily Retrofits | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    » Multifamily Retrofits » Training on Multifamily Retrofits Training on Multifamily Retrofits Training on Multifamily Retrofits Ensure the people making decisions and installing measures in your buildings are properly trained to deal with multifamily properties by taking advantage of our national training network. DOE's Weatherization Assistance Program supports full-service training centers that specialize in multifamily retrofit training. These organizations offer professional training to

  17. National Grid Deep Energy Retrofit Pilot

    SciTech Connect (OSTI)

    Neuhauser, K.

    2012-03-01

    Through discussion of five case studies (test homes), this project evaluates strategies to elevate the performance of existing homes to a level commensurate with best-in-class implementation of high-performance new construction homes. The test homes featured in this research activity participated in Deep Energy Retrofit (DER) Pilot Program sponsored by the electric and gas utility National Grid in Massachusetts and Rhode Island. Building enclosure retrofit strategies are evaluated for impact on durability and indoor air quality in addition to energy performance.

  18. Advanced Energy Retrofit Guides | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    implemented similar measures in commercial buildings. All of the AERGs are available for free download: Advanced Energy Retrofit Guide for Office Buildings Advanced Energy...

  19. 56th and Walnut: A Philly Gut Rehab Development, Philadelphia, Pennsylvania (Fact Sheet), Building America Case Study: Whole-House Solutions for Existing Homes, Building Technologies Office (BTO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    56th and Walnut: A Philly Gut Rehab Development Philadelphia, Pennsylvania PROJECT INFORMATION Construction: Deep energy retrofit of 32 apartments Type: Multifamily, affordable Partners: Columbus Property Management and Development, Inc. www.columbuspm.org Consortium for Advanced Residential Buildings www.carb-swa.com Size: 461 to 999 ft 2 Date completed: 2012 Climate Zone: Mixed-humid PERFORMANCE DATA HERS index post-retrofit: 67-76 Projected annual energy cost savings per unit: $707 Projected

  20. Improving the Field Performance of Natural Gas Furnaces, Chicago, Illinois (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    the Field Performance of Natural Gas Furnaces Chicago, Illinois PROJECT INFORMATION Project Name: Improving Gas Furnace Performance-A Field and Lab Study at End of Life Location: Chicago, IL Partnership for Advanced Residential Retrofit www.gastechnology.org Building Component: Natural Gas Furnaces Application: New and/or retrofit; Single and/or multifamily Year Tested: 2012/2013 Applicable Climate Zone(s): All or specify which ones PERFORMANCE DATA Cost of Energy Efficiency Measure (including

  1. Client and Tenant Education on Multifamily Retrofits | Department of Energy

    Office of Environmental Management (EM)

    Client and Tenant Education on Multifamily Retrofits Client and Tenant Education on Multifamily Retrofits Client education is a critical step in successful building retrofits. | Photo by Dennis Schroeder, NREL 28546 Client education is a critical step in successful building retrofits. | Photo by Dennis Schroeder, NREL 28546 Even the best energy retrofit plans work only as well as the people occupying the building will allow. The Weatherization Assistance Program understands that a building is

  2. Concord Four Square Retrofit

    SciTech Connect (OSTI)

    2010-07-09

    This case study describes the retrofit of a home in West Concord, Massachusetts that proved that a 50% reduction in home energy use could be met today in existing housing.

  3. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    In this project, researchers from Building Science Corporation investigated issues to better understand the mechanics behind the addition of insulation to the exterior of buildings ...

  4. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building America Whole-House Solutions for New Homes: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York Building America ...

  5. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Performance of a Double-Stud Cellulose Wall, Devens, Massachusetts In this project, the Building America research team Consortium for Advanced Residential Buildings monitored a...

  6. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Florida (Fact Sheet) In a study of three single-story houses in Florida, the Building America research team Consortium for Advanced Residential Buildings (CARB)...

  7. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Vapor Permeable Insulating Sheathing (Fact Sheet) In this project, Building America team Building Science Corporation researched some of the ramifications of using exterior,...

  8. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Residential Applications, Ithaca, New York (Fact Sheet) In this project, researchers from Building America team Consortium for Advanced Residential Buildings worked with industry...

  9. Building America Whole-House Solutions for Existing Homes: Evaluation...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cost-Optimized Solutions, Chicago, Illinois This case study presents information about a ... Building Energy Optimization Analysis Method (BEopt) - Building America Top Innovation ...

  10. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Florida (Fact Sheet) This case study examines a Building America builder partner's implementation of an inexpensive, quick and effective method of building a fur-down or ...

  11. Building America Technology Solutions for New and Existing Homes...

    Broader source: Energy.gov (indexed) [DOE]

    Climate Regions by County Building America Expert Meeting: Recommended Approaches to Humidity Control in High Performance Homes Building America Best Practices Series Volume...

  12. Steam Systems, Retrofit Measure Packages, Hydronic Systems

    Energy Savers [EERE]

    Program www.buildingamerica.gov Decker Homes Buildings Technologies Program Steam Systems, Retrofit Measure Packages, Hydronic Systems Russell Ruch Elevate Energy Peter Ludwig Elevate Energy July 16, 2014 Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings Contents * Retrofit Measure Packages for steam and hydronic MF buildings that save 25-30% * System Balancing * Steam * Hydronic 2 | Building America Program www.buildingamerica.gov Background

  13. Strategy Guideline. Mitigation of Retrofit Risk Factors

    SciTech Connect (OSTI)

    Berman, M.; Smith, P.; Porse, E.

    2012-12-01

    The Alliance for Residential Building Innovation (ARBI) Building America team is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

  14. Cladding Attachment Over Thick Exterior Insulating Sheathing (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cladding Attachment Over Thick Exterior Insulating Sheathing Project InformatIon: Project name: Cladding Attachment Over Thick Exterior Insulating Sheathing Partners: Building Science Corporation www.buildingscience.com The Dow Chemical Company www.dow.com James Hardie Building Products www.jameshardie.com Building component: Building envelope component application: New and/or retrofit; Single and/or multifamily Year research conducted: 2011 through 2012 applicable climate Zone(s): All The

  15. Study of Multifamily Energy Retrofit Using Flexible Multizone Building Simulation Model

    Broader source: Energy.gov [DOE]

    This presentation was delivered at the U.S. Department of Energy Building America Technical Update meeting on April 29-30, 2013, in Denver, Colorado.

  16. Building America Whole-House Solutions for Existing Homes: Conway...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    multifamily buildings. In this project, the team helped to transform a 100-year-old empty school building into 12 high performance apartments with low energy costs. The advanced...

  17. Multifamily Energy Savings Program (Existing Buildings and New Construction)

    Broader source: Energy.gov [DOE]

    To begin participating in the program, eligible building owners/managers work with a Focus Energy Advisor to perform a free energy assessment and identify suitable building improvements. For...

  18. Mesquite Solar Plan - build out next to existing FF plants Solar...

    Open Energy Info (EERE)

    Mesquite Solar Plan - build out next to existing FF plants Solar Power Plant Jump to: navigation, search Name Mesquite Solar Plan - build out next to existing FF plants Solar Power...

  19. Building America Webinar: Low-E Storms: The Next Big Thing in Window Retrofits

    Broader source: Energy.gov [DOE]

    This Building America webinar presented a new and improved low-e storm window that boasts a combination of curb appeal and energy efficiency, all for a fraction of the cost of window replacement, on Sept. 9, 2014.

  20. Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring

    SciTech Connect (OSTI)

    Dentz, J.; Henderson, H.; Varshney, K.

    2013-10-01

    The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. of Cambridge, Massachusetts, to implement and study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating control systems in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded.

  1. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Advanced Envelope Research for Factory Built Housing, Phase 3-Design Development and Prototyping Advanced Envelope Research for Factory-Built Housing Building America Expert...

  2. Guiding Principles for Sustainable Existing Buildings: Radiochemical Processing Laboratory

    SciTech Connect (OSTI)

    Pope, Jason E.

    2013-11-11

    In 2006, the United States (U.S.) Department of Energy (DOE) signed the Federal Leadership in High Performance and Sustainable Buildings Memorandum of Understanding (MOU), along with 21 other agencies. Pacific Northwest National Laboratory (PNNL) is exceeding this requirement and, currently, about 25 percent of its buildings are High Performance and Sustainable Buildings. The pages that follow document the Guiding Principles conformance effort for the Radiochemical Processing Laboratory (RPL) at PNNL. The RPL effort is part of continued progress toward a building inventory that is 100 percent compliant with the Guiding Principles.

  3. Building America Technology Solutions for Existing Homes: Initial...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    This research conducted by Building Science Corporation evaluated the system mechanics and long-term performance of the use of wood furring strips attached through the insulation ...

  4. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Sheeting over Aggregate, Southwestern Pennsylvania (Fact Sheet) In this project, Building America team IBACOS worked with a builder of single- and multifamily homes in...

  5. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of the wall is not easily or inexpensively accessible. This approach by the NorthernSTAR Building America Partnership team addresses thermal and moisture management from the...

  6. Building America Whole-House Solutions for Existing Homes: Passive...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fresno, California (Fact Sheet) In this project, IBACOS, a U.S. Department of Energy Building America team, assessed a strategy for providing conditioned air to bedrooms when...

  7. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Using Injected Spray Sealant In this project, the Raleigh Housing Authority worked with Building America team, the Advanced Residential Integrated Solutions Collaborative, to...

  8. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    This case study describes Building Science Corporation's research into spray polyurethane foams in residential roofs, performing hygrothermal modeling of a range of rain water ...

  9. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Ventilation Strategies in New Construction Multifamily Buildings, New York, New York (Fact ... Homes: Evaluation of Ventilation Strategies in New Construction Multifamily ...

  10. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    The excavationless process could result in even greater savings since replacement of building structures, exterior features, utility meters, and landscaping would be minimal or ...

  11. Interim Final Report for the Strengthening Retrofit Markets for Comprehensive Savings in Multifamily Buildings

    SciTech Connect (OSTI)

    Meinking, Rick; Adamson, Joy M

    2013-12-20

    Energy efficiency is vitally important in Maine. Nearly 70% of Maine households rely on fuel oil as their primary energy source for home heating, a higher share than in any other state. Coupled with the state's long, cold winters, Maine's dependence on oil renders homeowners particularly vulnerable to fluctuating fuel costs. With $4.5 million in seed funding from the Energy Department's Better Buildings Neighborhood Program, the Governor's Energy Office (GEO), through Efficiency Maine Trust (the Trust), is spurring Maine landlords to lower their monthly energy bills and improve comfort for their tenants during the state's cold winter months and increasingly warmer summers. Maine's aging multifamily housing stock can be expensive to heat and costly to maintain. It is not unusual to find buildings with little or no insulation, drafty windows, and significant air leaks, making them ideal candidates for energy efficiency upgrades. Maine modeled its Multifamily Efficiency Program (MEP) after the state's highly successful Home Energy Savings Program (HESP) for single?family homes. HESP provided cash incentives and financing opportunities to owners of one? to four?unit structures, which resulted in thousands of energy assessments and whole?house energy upgrades in 225 communities. Maine's new MEP multifamily energy efficiency upgrade and weatherization initiative focuses on small to medium?sized (i.e., five to 20 units) apartment buildings. The program's energy efficiency upgrades will provide at least 20% energy savings for each upgraded multifamily unit. The Trusts MEP relies on a network of approved program partners who help move projects through the pipeline from assessment to upgrade. MEP has two components: benchmarking and development of an Energy Reduction Plan (ERP). Using the ENERGY STAR Portfolio Manager benchmarking tool, MEP provides an assessment of current energy usage in the building, establishes a baseline for future energy efficiency improvements, and enables tracking and monitoring of future energy usage at the building all at no cost to the building owner. The ERP is developed by a program partner using either the Trusts approved modeling or prescriptive tools; it provides detailed information about the current energyrelated conditions in the building and recommends energy efficiency, health, and safety improvements. The Trust's delivery contractor provides quality assurance and controls throughout the process. Through this effort, MEP's goal is to establish a self?sustaining, market?driven program, demonstrating the value of energy efficiency to other building owners. The increasing value of properties across the state will help incentivize these owners to continue upgrades after the grant period has ended. Targeting urban areas in Maine with dense clusters of multifamily unitssuch as Portland, Lewiston? Auburn, Bangor, and AugustaMEP engaged a variety of stakeholder groups early on to design its multifamily program. Through direct emails and its website, program officials invited lending institutions, building professionals, engineering firms, equipment distributors, and local property owners associations to attend open meetings around the state to learn about the goals of the multifamily program and to help define its parameters. These meetings helped program administrators understand the diversity of the customer base: some owners are individuals with a single building, while other owners are groups of people or management companies with an entire portfolio of multifamily buildings. The diversity of the customer base notwithstanding, owners see MEP as an opportunity to make gains in their respective properties. Consistently high turnouts at stakeholder meetings fueled greater customer interest as awareness of the program spread through word of mouth. The program also gained traction by utilizing the program partner networks and building on the legacy of the Trusts successful HESP for single?family residences. MEP offers significant incentives for building owners to p

  12. Wyandotte Neighborhood Stabilization Program: Retrofit of Two Homes

    SciTech Connect (OSTI)

    Lukachko, A.; Grin, A.; Bergey, D.

    2013-04-01

    The Wyandotte NSP2 project aims to build 20 new houses and retrofit 20 existing houses in Wyandotte, MI. This report will detail the retrofit of 2 existing houses in the program. Wyandotte is part of a Michigan State Housing Development Authority-led consortium that is funded by HUD under the NSP2 program. The City of Wyandotte has also been awarded DOE EE&CBG funds that are being used to develop a district GSHP system to service the project. This draft report examines the energy efficiency recommendations for retrofit construction at these homes. The report will be of interest to anyone planning an affordable, high performance retrofit of an existing home in a Cold Climate zone. Information from this report will also be useful to retrofit or weatherization program staff as some of the proposed retrofit solutions will apply to a wide range of projects. Preliminary results from the first complete house suggest that the technology package employed (which includes spray foam insulation and insulating sheathing) does meet the specific whole house water, air, and thermal control requirements, as well as, the project's affordability goals. Monitoring of the GSHP system has been recommended and analysis of this information is not yet available.

  13. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and analyzed the data from 941 multifamily buildings in the Northeast and Mid-Atlantic regions to outline the heating and cooling design load characteristics of low-load dwellings. ...

  14. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Researchers from Alliance for Residential Building Initiative worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump systems, ...

  15. Building America Technology Solutions for New and Existing Homes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    in a Cold Climate, New Paltz, New York In this study, the U.S. Department of Energy's team Building America Partner-ship for Improved Residential Construction (BA-PIRC) worked...

  16. Building America Whole-House Solutions for Existing Homes: Passive...

    Energy Savers [EERE]

    this project, IBACOS, a U.S. Department of Energy Building America team, assessed a strategy for providing conditioned air to bedrooms when the bedroom doors are closed and...

  17. Strategy Guideline: Mitigation of Retrofit Risk Factors

    SciTech Connect (OSTI)

    Berman, M.; Smith, P.; Porse, E.

    2012-12-01

    The Alliance for Residential Building Innovation (ARBI) is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

  18. Installation on Multifamily Retrofits | Department of Energy

    Office of Environmental Management (EM)

    Multifamily Retrofits » Installation on Multifamily Retrofits Installation on Multifamily Retrofits Over the last thirty years, DOE's Weatherization Assistance Program has cultivated the most experienced and connected group of whole-building energy retrofit professionals in the nation. The Weatherization Program has weatherized nearly 300,000 multifamily units since Graphic describing the Weatherization workforce as trained, equipped, and accountable. 2010. Many groups within the Weatherization

  19. National Grid Deep Energy Retrofit Pilot

    SciTech Connect (OSTI)

    Neuhauser, K.

    2012-03-01

    Through discussion of five case studies (test homes), this project evaluates strategies to elevate the performance of existing homes to a level commensurate with best-in-class implementation of high-performance new construction homes. The test homes featured in this research activity participated in Deep Energy Retrofit (DER) Pilot Program sponsored by the electric and gas utility National Grid in Massachusetts and Rhode Island. Building enclosure retrofit strategies are evaluated for impact on durability and indoor air quality in addition to energy performance. Evaluation of strategies is structured around the critical control functions of water, airflow, vapor flow, and thermal control. The aim of the research project is to develop guidance that could serve as a foundation for wider adoption of high performance, 'deep' retrofit work. The project will identify risk factors endemic to advanced retrofit in the context of the general building type, configuration and vintage encountered in the National Grid DER Pilot. Results for the test homes are based on observation and performance testing of recently completed projects. Additional observation would be needed to fully gauge long-term energy performance, durability, and occupant comfort.

  20. Hydronic Heating Retrofits for Low-Rise Multifamily Buildings - Phase 1: Boiler Control Replacement and Monitoring

    SciTech Connect (OSTI)

    Dentz, J.; Henderson, H.

    2012-04-01

    The ARIES Collaborative, a Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, MA to implement and study improvements to the heating system in one of the non-profit's housing developments. The heating control systems in the 42-unit Columbia CAST housing development were upgraded in an effort projected to reduce heating costs by 15 to 25 percent.

  1. Building America Expert Meeting Final Report: Multifamily Hydronic and Steam Heating Controls and Distribution Retrofits

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Hydronic Heating in Multifamily Buildings Jordan Dentz The ARIES Collaborative October 2011 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or

  2. Building America Technology Solutions for New and Existing Homes: Combustion Safety Using Appliances for Indoor Air (Fact Sheet)

    Broader source: Energy.gov [DOE]

    In this case study, the Partnership for Advanced Residential Retrofit team provides guidance on how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings.

  3. Building America Webinar: Introduction - Who's Successfully Doing...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Introduction - Who's Successfully Doing Deep Energy Retrofits? Building America Webinar: Introduction - Who's Successfully Doing Deep Energy Retrofits? This presentation provides...

  4. Quantifying the Financial Benefits of Multifamily Retrofits

    SciTech Connect (OSTI)

    D. Philbrick; Scheu, R.; Brand, L.

    2016-01-01

    The U.S. Department of Energy’s Building America research team Partnership for Advanced Residential Retrofit analyzed building, energy, and financial program data as well as other public and private data to examine the relationship between energy-efficiency retrofits and financial performance on three levels: building, city, and community.

  5. Strategy Guideline: Quality Management in Existing Homes; Cantilever Floor Example

    SciTech Connect (OSTI)

    Taggart, J.; Sikora, J.; Wiehagen, J.; Wood, A.

    2011-12-01

    This guideline is designed to highlight the QA process that can be applied to any residential building retrofit activity. The cantilevered floor retrofit detailed in this guideline is included only to provide an actual retrofit example to better illustrate the QA activities being presented. The goal of existing home high performing remodeling quality management systems (HPR-QMS) is to establish practices and processes that can be used throughout any remodeling project. The research presented in this document provides a comparison of a selected retrofit activity as typically done versus that same retrofit activity approached from an integrated high performance remodeling and quality management perspective. It highlights some key quality management tools and approaches that can be adopted incrementally by a high performance remodeler for this or any high performance retrofit. This example is intended as a template and establishes a methodology that can be used to develop a portfolio of high performance remodeling strategies.

  6. Replacement, Variable-Speed Motors for Furnaces, Syracuse, New York (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    Replacement of Variable-Speed Motors for Furnaces Syracuse, New York PROJECT INFORMATION Project Name: Evaluation of Concept 3 BPM motors Location: Syracuse, NY Partners: New York State Energy Research and Development Authority (NYSERDA) www.nyserda.org Proctor Engineering Group (PEG) www.proctoreng.com Tag Mechanical www.taghomeperformance.com/ Consortium for Advanced Residential Buildings www.carb-swa.com Building Component: HVAC Application: Retrofit, homes with forced air distribution Year

  7. Building America Efficient Solutions for Existing Homes Case Study: Habitat for Humanity South Sarasota County, Venice, Florida

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Project Description Building America researchers provided technical assistance to Habitat for Humanity (HFH) of South Sarasota County, Florida, to achieve a deep energy retrofit featuring an innovative way to air seal an entire home, which also moved its ducts and air handler inside the thermal boundary. This home (a 1978, single-story, three-bedroom, two-bath with attached-garage) is typical of many in central and south Florida, and Building America plans to use monitored utility data from the

  8. Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago

    SciTech Connect (OSTI)

    Neuhauser, Ken

    2013-08-01

    This project examines the implementation of an exterior insulation and over-clad strategy for brick masonry buildings in Chicagoa free-standing two story two-family dwelling and a larger free-standing multifamily building. The test homes selected for this research represent predominant housing types for the Chicago area, in which high heating energy use typical in these buildings threaten housing affordability, and uninsulated mass masonry wall assemblies are uncomfortable for residents. In this project, the Community and Economic Development Association of Cook County, Inc. (CEDA) has secured a Sustainable Energy Resources for Consumers (SERC) innovation grant sponsored by DOE to pursue a pilot implementation of innovative approaches to retrofit in masonry wall enclosures. The retrofit measures are evaluated in terms of feasibility, cost and performance. Through observations of the strategies implemented, the research described in this report identifies measures critical to performance as well as conditions for wider adoption. The research also identifies common factors that must be considered in determining whether the exterior insulation and over-clad strategy is appropriate for the building.

  9. Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago

    SciTech Connect (OSTI)

    Neuhauser, K.

    2013-08-01

    This project examines the implementation of an exterior insulation and over-clad strategy for brick masonry buildings in Chicago. The strategy was implemented at a free-standing two story two-family dwelling and a larger free-standing multifamily building. The test homes selected for this research represent predominant housing types for the Chicago area. High heating energy use typical in these buildings threaten housing affordability. Uninsulated mass masonry wall assemblies also have a strongly detrimental impact on comfort. Significant changes to the performance of masonry wall assemblies is generally beyond the reach of typical weatherization (Wx) program resources. The Community and Economic Development Association of Cook County, Inc. (CEDA) has secured a Sustainable Energy Resources for Consumers (SERC) innovation grant sponsored by the United States Department of Energy (DOE). This grant provides CEDA the opportunity to pursue a pilot implementation of innovative approaches to retrofit in masonry wall enclosures. The exterior insulation and over-clad strategy implemented through this project was designed to allow implementation by contractors active in CEDA weatherization programs and using materials and methods familiar to these contractors. The retrofit measures are evaluated in terms of feasibility, cost and performance. Through observations of the strategies implemented, the research described in this report identifies measures critical to performance as well as conditions for wider adoption. The research also identifies common factors that must be considered in determining whether the exterior insulation and over-clad strategy is appropriate for the building.

  10. Building America Expert Meeting: Windows Options for New and Existing Homes

    Energy Savers [EERE]

    | Department of Energy Windows Options for New and Existing Homes Building America Expert Meeting: Windows Options for New and Existing Homes The NorthernSTAR Building America Partnership held an Expert Meeting on Windows Options for New and Existing Homes on November 14, 2011 at the Nolte Building on the campus of the University of Minnesota in Minneapolis, MN. Featured speakers included John Carmody and Pat Huelman of the University of Minnesota, Charlie Curcija of Lawrence Berkeley

  11. Geothermal Energy Retrofit

    SciTech Connect (OSTI)

    Bachman, Gary

    2015-07-28

    The Cleary University Geothermal Energy Retrofit project involved: 1. A thermal conductivity test; 2. Assessment of alternative horizontal and vertical ground heat exchanger options; 3. System design; 4. Asphalt was stripped from adjacent parking areas and a vertical geothermal ground heat exchanger system installed; 5. the ground heat exchanger was connected to building; 6. a system including 18 heat pumps, control systems, a manifold and pumps, piping for fluid transfer and ductwork for conditioned air were installed throughout the building.

  12. Crowne Plaza Renovation Retrofit Case Study

    SciTech Connect (OSTI)

    none,

    2013-03-01

    InterContinental Hotels Group (IHG) and its franchise partner B.F. Saul Company Hospitality Group (B.F. Saul Co.) partnered with the Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce energy consumption by at least 30% versus requirements set by Standard 90.1-2004 of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of North America (IESNA) as part of DOEs Commercial Building Partnerships (CBP) Program.

  13. Deep Energy Retrofit Case Studies: Lessons Learned

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Deep Energy Retrofit Case Studies: Lessons Learned. Alea German Alliance for Residential Building Innovation June 25, 2014 Davis Energy Group | June 25, 2014 ‹#› Agenda * Background / motivation * Results from 3 CA retrofits - Sonoma Passive House Retrofit - Stockton Hot Dry Retrofit - Sunnyvale Marine Deep Retrofit Davis Energy Group | June 25, 2014 ‹#› Background * >60 million homes in the U.S. over 30 yrs old * Huge potential - Energy savings ‹#› Davis Energy Group | June 25,

  14. Achieving a Net Zero Energy Retrofit: Lessons from the University of Hawaii at Manoa

    SciTech Connect (OSTI)

    2013-03-01

    The University of Hawaii at Manoa (UHM) partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce energy consumption by at least 30% as part of DOEs Commercial Building Partnerships (CBP) Program.

  15. National Residential Efficiency Measures Database Aimed at Reducing Risk for Residential Retrofit Industry (Fact Sheet), Building America: Technical Highlight, Building Technologies Program (BTP)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Residential Efficiency Measures Database Aimed at Reducing Risk for Residential Retrofit Industry Researchers at the U.S. Department of Energy (DOE) National Renewable Energy Laboratory (NREL) have developed the National Residential Efficiency Measures Database, a public database that characterizes the performance and costs of common residential energy efficiency measures. The data are available for use in software programs that evaluate cost- effective retrofit measures to improve the energy

  16. Cascade Apartments - Deep Energy Multifamily Retrofit , Kent, Washington (Fact Sheet), Building America Case Study: Whole-House Solutions for New Homes, Building Technologies Office (BTO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cascade Apartments - Deep Energy Multifamily Retrofit Kent, Washington PROJECT INFORMATION Construction: Retrofit Type: Multifamily, affordable Builder: King County Housing Authority, Kent, Washington http://www.kcha.org/ Size: 108 units in 27 four-plexes Rent: 30% of household income Date completed: 2010 Climate Zone: Marine PERFORMANCE DATA State low-income weatherization investment: $385,850 for all 108 units $15,850 per 4-plex $3,858 per unit Site savings per unit: Billing analysis:

  17. Wyandotte Neighborhood Stabilization Program: Retrofit of Two Homes

    SciTech Connect (OSTI)

    Lukachko, A.; Grin, A.; Bergey, D.

    2013-04-01

    The Wyandotte NSP2 project aims to build 20 new houses and retrofit 20 existing houses in Wyandotte, MI. Wyandotte is part of a Michigan State Housing Development Authority-led consortium that is funded by HUD under the NSP2 program. The City of Wyandotte has also been awarded DOE EE&CBG funds that are being used to develop a district ground source heat pump (GSHP) system to service the project. This report details the retrofit of two existing houses in the program, and examines the energy efficiency recommendations for the homes. The report will be of interest to anyone planning an affordable, high performance retrofit of an existing home in a cold climate zone. Information from this report will also be useful to retrofit or weatherization program staff as some of the proposed retrofit solutions will apply to a wide range of projects. Preliminary results from the first complete house suggest that the technology package employed (which includes spray foam insulation and insulating sheathing) does meet the specific whole house water, air, and thermal control requirements, as well as, the projects affordability goals. Monitoring of the GSHP system has been recommended and analysis of this information is not yet available.

  18. Cold Climate and Retrofit Applications for Air-to-Air Heat Pumps

    SciTech Connect (OSTI)

    Baxter, Van D [ORNL

    2015-01-01

    Air source heat pumps (ASHP) including air-to-air ASHPs are easily applied to buildings almost anywhere for new construction as well as retrofits or renovations. They are widespread in milder climate regions but their use in cold regions is hampered due to low heating efficiency and capacity at cold outdoor temperatures. Retrofitting air-to-air ASHPs to existing buildings is relatively easy if the building already has an air distribution system. For buildings without such systems alternative approaches are necessary. Examples are ductless, minisplit heat pumps or central heat pumps coupled to small diameter, high velocity (SDHV) air distribution systems. This article presents two subjects: 1) a summary of R&D investigations aimed at improving the cold weather performance of ASHPs, and 2) a brief discussion of building retrofit options using air-to-air ASHP systems.

  19. Building America Technology Solutions for New and Existing Homes:Hydronic

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Systems Designing for Setback Operations | Department of Energy Building America Technology Solutions for New and Existing Homes:Hydronic Systems Designing for Setback Operations Building America Technology Solutions for New and Existing Homes:Hydronic Systems Designing for Setback Operations This guide, developed by Consortium for Advanced Residential Buildings, provides step-by-step instructions for heating contractors and hydronic designers for selecting the proper control settings to

  20. OTEC- Commercial Lighting Retrofit Rebate Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    The Oregon Trail Electric Consumers Cooperative (OTEC) offers a commercial lighting retrofit program that provides rebates for commercial businesses that change existing lighting to more energy...

  1. Pilot Residential Deep Energy Retrofits and the PNNL Lab Homes

    SciTech Connect (OSTI)

    Widder, Sarah H.; Chandra, Subrato; Parker, Graham B.; Sande, Susan; Blanchard, Jeremy; Stroer, Dennis; McIlvaine, Janet; Chasar, David; Beal, David; Sutherland, Karen

    2012-01-01

    This report summarizes research investigating the technical and economic feasibility of several pilot deep energy retrofits, or retrofits that save 30% to 50% or more on a whole-house basis while increasing comfort, durability, combustion safety, and indoor air quality. The work is being conducted for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. As part of the overall program, Pacific Northwest National Laboratory (PNNL) researchers are collecting and analyzing a comprehensive dataset that describes pre- and post-retrofit energy consumption, retrofit measure cost, health and comfort impacts, and other pertinent information for each home participating in the study. The research and data collection protocol includes recruitment of candidate residences, a thorough test-in audit, home energy modeling, and generation of retrofit measure recommendations, implementation of the measures, test-out, and continued evaluation. On some homes, more detailed data will be collected to disaggregate energy-consumption information. This multi-year effort began in October 2010. To date, the PNNL team has performed test-in audits on 51 homes in the marine, cold, and hot-humid climate zones, and completed 3 retrofits in Texas, 10 in Florida, and 2 in the Pacific Northwest. Two of the retrofits are anticipated to save 50% or more in energy bills and the others - savings are in the 30% to 40% range. Fourteen other retrofits are under way in the three climate zones. Metering equipment has been installed in seven of these retrofits - three in Texas, three in Florida, and one in the Pacific Northwest. This report is an interim update, providing information on the research protocol and status of the PNNL deep energy retrofit project as of December, 2011. The report also presents key findings and lessons learned, based on the body of work to date. In addition, the report summarizes the status of the PNNL Lab Homes that are new manufactured homes procured with minimal energy-efficiency specifications typical of existing homes in the region, and sited on the PNNL campus. The Lab Homes serve as a flexible test facility (the first of its kind in the Pacific Northwest) to rapidly evaluate energy-efficient and grid-smart technologies that are applicable to residential construction.

  2. Bedford Farmhouse High Performance Retrofit Prototype

    SciTech Connect (OSTI)

    2010-04-26

    In this case study, Building Science Corporation partnered with Habitat for Humanity of Greater Lowell on a retrofit of a mid-19th century farmhouse into affordable housing meeting Building America performance standards.

  3. Building America Whole-House Solutions for Existing Homes: 56th and Walnut:

    Energy Savers [EERE]

    A Philly Gut Rehab Development | Department of Energy Building America Whole-House Solutions for Existing Homes: 56th and Walnut: A Philly Gut Rehab Development Building America Whole-House Solutions for Existing Homes: 56th and Walnut: A Philly Gut Rehab Development In this project, CPM partnered with the Consortium for Advanced Residential Buildings team to renovate 32 units in 11 three-story, historic, brick masonry urban buildings. PDF icon 56th and Walnut: A Philly Gut Rehab Development

  4. Building America Case Study: Advanced Boiler Load Monitoring Controllers, Chicago, Illinois (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Boiler Load Monitoring Controllers Chicago, Illinois PROJECT INFORMATION Project Name: Field Test of Boiler Primary Loop Temperature Controller Location: Chicago, IL Partners: Partnership for Advanced Residential Retrofit (PARR), gastechnology.org/PARR Greffen Systems, greffensys.com Building Component: HVAC Application: New or retrofit; multifamily Year Tested: 2013-2014 Applicable Climate Zones: Cold, Very Cold, Mixed-Humid PERFORMANCE DATA Cost of energy efficiency measure (including labor):

  5. Field Assessment of Energy Audit Tools for Retrofit Programs

    SciTech Connect (OSTI)

    Edwards, J.; Bohac, D.; Nelson, C.; Smith, I.

    2013-07-01

    This project focused on the use of home energy ratings as a tool to promote energy retrofits in existing homes. A home energy rating provides a quantitative appraisal of a homes energy performance, usually compared to a benchmark such as the average energy use of similar homes in the same region. Rating systems based on energy performance models, the focus of this report, can establish a homes achievable energy efficiency potential and provide a quantitative assessment of energy savings after retrofits are completed, although their accuracy needs to be verified by actual measurement or billing data. Ratings can also show homeowners where they stand compared to their neighbors, thus creating social pressure to conform to or surpass others. This project field-tested three different building performance models of varying complexity, in order to assess their value as rating systems in the context of a residential retrofit program: Home Energy Score, SIMPLE, and REM/Rate.

  6. Deep Energy Retrofits

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    High Performance High Performance Enclosure Strategies: Part I Existing Home Part I, Existing Home Deep Energy Retrofits Anastasia Herk IBACOS Project Partners Manufacturers, Contractors, NYSERDA, Engineers 2 Goals of Research Project: * Evaluate cost and performance trade offs between: - Spray-foam exterior walls - Rigid foam exterior walls - Home Performance with Energy Star Home (HPwES) on steroids * 50% peak load and annual heating load reduction * R-30Target for Center of Wall * .25 CFM50

  7. Building America Case Study: Philadelphia Housing Authority Energy-Efficiency Turnover Protocols, Philadelphia, Pennsylvania (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Energy Savers [EERE]

    Philadelphia Housing Authority Energy-Efficiency Turnover Protocols Philadelphia, Pennsylvania PROJECT INFORMATION Project Name: Philadelphia Housing Authority Unit Turnover Retrofit Program Location: Philadelphia, PA Partners: Philadelphia Housing Authority, pha.phila.gov Advanced Residential Integrated Solutions Collaborative (ARIES), levypartnership.com Building Component: Whole-building Application: Retrofit; multifamily Year Tested: 2014 Applicable Climate Zones: All, with greater benefits

  8. Sunnyvale Marine Climate Deep Retrofit

    SciTech Connect (OSTI)

    German, A.; Siddiqui, A.; Dakin, B.

    2014-11-01

    The Alliance for Residential Building Innovation (ARBI) and Allen Gilliland of One Sky Homes collaborated on a marine climate retrofit project designed to meet both Passive House (PH) and Building America (BA) program standards. The scope included sealing, installing wall, roof and floor insulation (previously lacking), replacing windows, upgrading the heating and cooling system, and installing.

  9. Sunnyvale Marine Climate Deep Retrofit

    SciTech Connect (OSTI)

    German, A.; Siddiqui, A.; Dakin, B.

    2014-11-01

    The Alliance for Residential Building Innovation (ARBI) and Allen Gilliland of One Sky Homes collaborated on a marine climate retrofit project designed to meet both Passive House (PH) and Building America program standards. The scope included sealing, installing wall, roof and floor insulation (previously lacking), replacing windows, upgrading the heating and cooling system, and installing mechanical ventilation.

  10. Improving the Energy Performance of New and Existing Commercial Buildings: A DOE Status Report

    SciTech Connect (OSTI)

    Holuj, Brian; Nicholls, Andrew K.; Sandahl, Linda J.; Torcellini, Paul

    2010-08-01

    It is technically and economically feasible for our nations commercial buildings to consume substantially less energy--and produce substantially less carbon dioxide--than they do. Yet owners of existing buildings are not taking full advantage of todays best energy saving technologies and practices; and developers of new buildings are, most often, constructing to minimum energy codes rather than pushing for greater efficiency. The U.S. Department of Energy (DOE) is addressing these challenges by developing cost-effective technologies and practices that deliver significant improvements in commercial building performance. DOE, through its Commercial Building Initiative, is also collaborating with industry-leading companies and organizations to demonstrate, monitor, and help move these technologies from the laboratory to the marketplace. Ultimately, DOEs dual strategy of pairing aggressive research and development with market engagement, demonstration, and deployment will dramatically improve the energy performance of new and existing commercial buildings throughout the nation.

  11. Hawaii Clean Energy Initiative Existing Building Energy Efficiency Analysis: November 17, 2009- June 30, 2010

    Broader source: Energy.gov [DOE]

    This report presents the results of the Booz Allen Hamilton study on the existing building stock of Hawaii, along with conclusions on the key drivers of potential energy efficiency savings and on the steps necessary to attain them.

  12. Best Practices for HPSB Guiding Principles Implementation in Existing DOE Buildings

    SciTech Connect (OSTI)

    Henderson, Jordan W.

    2014-05-06

    The intent of this paper is to document an approach to screening existing buildings at DOE sites for High-Performance and Sustainable Buildings (HPSB) Guiding Principles (GPs) potential, developing policies and programs to address a majority of the HPSB GPs, and how to prioritize buildings with the greatest potential. This paper will also include example strategies for HPSB inventory and projection schedules and best practices on approaching and interpreting select criteria that have been troublesome to sites.

  13. Building America Technology Solutions for New and Existing Homes: Duct in

    Energy Savers [EERE]

    Conditioned Space in a Dropped Ceiling or Fur-down, Gainesville, Florida (Fact Sheet) | Department of Energy in Conditioned Space in a Dropped Ceiling or Fur-down, Gainesville, Florida (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Duct in Conditioned Space in a Dropped Ceiling or Fur-down, Gainesville, Florida (Fact Sheet) This case study examines a Building America builder partner's implementation of an inexpensive, quick and effective method of building a

  14. Building America Whole-House Solutions for Existing Homes: Conway Street

    Energy Savers [EERE]

    Apartments - Greenfield, Massachusetts | Department of Energy Conway Street Apartments - Greenfield, Massachusetts Building America Whole-House Solutions for Existing Homes: Conway Street Apartments - Greenfield, Massachusetts Through recent research efforts, CARB has been evaluating strategies and technologies that can make dramatic improvements in energy performance in multifamily buildings. In this project, the team helped to transform a 100-year-old empty school building into 12 high

  15. Case study field evaluation of a systems approach to retrofitting a residential HVAC system

    SciTech Connect (OSTI)

    Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

    2003-09-01

    This case study focusing on a residence in northern California was undertaken as a demonstration of the potential of a systems approach to HVAC retrofits. The systems approach means that other retrofits that can affect the HVAC system are also considered. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC system can be used. Secondly, we wanted to examine the practical issues and interactions with contractors and code officials required to accomplish the systems approach because it represents a departure from current practice. We identified problems in the processes of communication and installation of the retrofit that led to compromises in the final energy efficiency of the HVAC system. These issues must be overcome in order for HVAC retrofits to deliver the increased performance that they promise. The experience gained in this case study was used to optimize best practices guidelines for contractors (Walker 2003) that include building diagnostics and checklists as tools to assist in ensuring the energy efficiency of ''house as a system'' HVAC retrofits. The best practices guidelines proved to be an excellent tool for evaluating the eight existing homes in this study, and we received positive feedback from many potential users who reviewed and used them. In addition, we were able to substantially improve the energy efficiency of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner, an economizer and by reducing duct leakage.

  16. Foundation Insulation for Existing Homes | Department of Energy

    Energy Savers [EERE]

    Foundation Insulation for Existing Homes Foundation Insulation for Existing Homes This presentation was delivered at the U.S. Department of Energy Building America Technical Update meeting on April 29-30, 2013, in Denver, Colorado. PDF icon cq1_foundation_insulation_huelman.pdf More Documents & Publications Critical Question #1: How Do We Retrofit the Tough Buildings? Excavationless Exterior Foundation Insulation Exploratory Building America Technology Solutions for New and Existing Homes:

  17. Pressure Regain Strategies for Existing Air Distribution Systems |

    Energy Savers [EERE]

    Department of Energy Pressure Regain Strategies for Existing Air Distribution Systems Pressure Regain Strategies for Existing Air Distribution Systems This presentation was delivered at the U.S. Department of Energy Building America Technical Update meeting on April 29-30, 2013, in Denver, Colorado. PDF icon cq1_pressure_regain_burdick.pdf More Documents & Publications Critical Question #1: How Do We Retrofit the Tough Buildings? Building America Technology Solutions for New and Existing

  18. Building America Whole-House Solutions for Existing Homes: Evaluation of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Missed Energy Saving Opportunity Based on Illinois Home Performance Program Field Data: Homeowner Selected Upgrades vs. Cost-Optimized Solutions, Chicago, Illinois | Department of Energy Building America Whole-House Solutions for Existing Homes: Evaluation of Missed Energy Saving Opportunity Based on Illinois Home Performance Program Field Data: Homeowner Selected Upgrades vs. Cost-Optimized Solutions, Chicago, Illinois Building America Whole-House Solutions for Existing Homes: Evaluation of

  19. Building America Technology Solutions for New and Existing Homes:Hydronic

    Energy Savers [EERE]

    Systems Designing for Setback Operations | Department of Energy Existing Homes:Hydronic Systems Designing for Setback Operations Building America Technology Solutions for New and Existing Homes:Hydronic Systems Designing for Setback Operations This guide, developed by Consortium for Advanced Residential Buildings, provides step-by-step instructions for heating contractors and hydronic designers for selecting the proper control settings to maximize system performance and improve response time

  20. Building America Case Study:Cladding Attachment Over Mineral Fiber Insulation Board (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Energy Savers [EERE]

    Cladding Attachment Over Mineral Fiber Insulation Board Ontario, Canada PROJECT INFORMATION Project Name: Climate-Exposed Long- Term Testing of Mineral Fiber Insulation Board Under Cladding Attachment Load Location: Ontario, Canada Partners: Building Science Laboratories, buildingsciencelabs.com Building Science Corporation, buildingscience.com Building Component: Above-grade frame wall Application: Both new construction and retrofit; wood-framed buildings Year Tested: 2012-2013 Applicable

  1. Retrofitting Doors on Open Refrigerated Cases | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Retrofitting Doors on Open Refrigerated Cases Retrofitting Doors on Open Refrigerated Cases Commercial Buildings Integration Project for the 2013 Building Technologies Office's Program Peer Review PDF icon commlbldgs18_goetzler_040413.pdf More Documents & Publications Better Buildings Alliance - 2013 BTO Peer Review Working Fluids Low Global Warming Potential Refrigerants - 2013 Peer Review Better Buildings Alliance Equipment Performance Specifications - 2013 BTO Peer

  2. Building America Technology Solutions for New and Existing Homes: Retrofit Integrated Space and Water Heating-Field Assessment

    Broader source: Energy.gov [DOE]

    In this project, the NorthernSTAR team analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water and forced air space heating.

  3. Building Energy Simulation Test for Existing Homes (BESTEST-EX); Phase 1 Test Procedure: Building Thermal Fabric Cases

    SciTech Connect (OSTI)

    Judkoff, R.; Polly, B.; Bianchi, M.; Neymark, J.

    2010-08-01

    The U.S. Department of Energy tasked NREL to develop a process for testing the reliability of models that predict retrofit energy savings, including their associated calibration methods. DOE asked NREL to conduct the work in phases so that a test procedure would be ready should DOE need it to meet legislative requirements related to residential retrofits in FY 2010. This report documents the initial 'Phase 1' test procedure.

  4. Engagement with Utilities on Multifamily Retrofits | Department of Energy

    Office of Environmental Management (EM)

    Weatherization Assistance Program » Multifamily Retrofits » Engagement with Utilities on Multifamily Retrofits Engagement with Utilities on Multifamily Retrofits Weatherization professionals often have existing relationships with the local utilities, which can facilitate access to helpful data. | Photo by Warren Gretz, NREL 04893 Weatherization professionals often have existing relationships with the local utilities, which can facilitate access to helpful data. | Photo by Warren Gretz, NREL

  5. Building America Technology Solutions for New and Existing Homes: Long-Term

    Energy Savers [EERE]

    Monitoring of Mini-Split Ductless Heat Pumps in the Northeast, Devens and Easthampton, Massachusetts | Department of Energy Long-Term Monitoring of Mini-Split Ductless Heat Pumps in the Northeast, Devens and Easthampton, Massachusetts Building America Technology Solutions for New and Existing Homes: Long-Term Monitoring of Mini-Split Ductless Heat Pumps in the Northeast, Devens and Easthampton, Massachusetts In this project, Building Science Corporation evaluated the long-term performance of

  6. Hawaii Clean Energy Initiative Existing Building Energy Efficiency Analysis: November 17, 2009 - June 30, 2010

    SciTech Connect (OSTI)

    Finch, P.; Potes, A.

    2010-06-01

    In June 2009, the State of Hawaii enacted an Energy Efficiency Portfolio Standard (EEPS) with a target of 4,300 gigawatt hours (GWh) by 2030 (Hawaii 2009). Upon setting this goal, the Hawaii Clean Energy Initiative, Booz Allen Hamilton (BAH), and the National Renewable Energy Laboratory (NREL), working with select local stakeholders, partnered to execute the first key step toward attaining the EEPS goal: the creation of a high-resolution roadmap outlining key areas of potential electricity savings. This roadmap was divided into two core elements: savings from new construction and savings from existing buildings. BAH focused primarily on the existing building analysis, while NREL focused on new construction forecasting. This report presents the results of the Booz Allen Hamilton study on the existing building stock of Hawaii, along with conclusions on the key drivers of potential energy efficiency savings and on the steps necessary to attain them.

  7. Building America Case Study: Predicting Envelope Leakage in Attached Dwellings (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Predicting Envelope Leakage in Attached Dwellings PROJECT INFORMATION Project Name: Predicting Envelope Leakage in Attached Dwellings Consortium for Advanced Residential Buildings, carb-swa.com Building Component: Building envelope Application: New and retrofit; multifamily Year Tested: 2013 Applicable Climate Zone(s): All POTENTIAL BENEFITS OF MODEL Requires substantially fewer resources in the field-equipment, personnel, and time, because only solo test values are needed. Does not require

  8. Conway Street Apartments: A Multifamily Deep Energy Retrofit...

    Office of Scientific and Technical Information (OSTI)

    CONSORTIUM FOR ADVANCED RESIDENTIAL BUILDINGS; MULTIFAMILY; RETROFIT; ZERO ENERGY; SOLAR THERMAL; DRAIN WATER RECOVERY SYSTEM; DEMAND-CONTROLLED RECIRCULATION SYSTEM; BRICK;...

  9. CBEI: Improving Code Compliance with Change of Occupancy Retrofits...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    with Change of Occupancy Retrofits - 2015 Peer Review More Documents & Publications Fossil Fuel-Generated Energy Consumption Reduction for New Federal Buildings and Major...

  10. CBEI: Packaged Masonry Wall Retrofit Solution for Small and Medium...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and Medium Sized Commercial Buildings - 2015 Peer Review Presenter: Mugdha Mokashi, Bayer Materials View the Presentation PDF icon CBEI: Packaged Masonry Wall Retrofit Solution...

  11. Advanced Energy Retrofit Guide (AERG): Practical Ways to Improve Energy Performance; Healthcare Facilities (Book)

    SciTech Connect (OSTI)

    Hendron, R.; Leach, M.; Bonnema, E.; Shekhar, D.; Pless, S.

    2013-09-01

    The Advanced Energy Retrofit Guide for Healthcare Facilities is part of a series of retrofit guides commissioned by the U.S. Department of Energy. By presenting general project planning guidance as well as detailed descriptions and financial payback metrics for the most important and relevant energy efficiency measures (EEMs), the guides provide a practical roadmap for effectively planning and implementing performance improvements in existing buildings. The Advanced Energy Retrofit Guides (AERGs) are intended to address key segments of the U.S. commercial building stock: retail stores, office buildings, K-12 schools, grocery stores, and healthcare facilities. The guides' general project planning considerations are applicable nationwide; the energy and cost savings estimates for recommended EEMs were developed based on energy simulations and cost estimates for an example hospital tailored to five distinct climate regions. These results can be extrapolated to other U.S. climate zones. Analysis is presented for individual EEMs, and for packages of recommended EEMs for two project types: existing building commissioning projects that apply low-cost and no-cost measures, and whole-building retrofits involving more capital-intensive measures.

  12. Increasing Property Value with Energy Saving Practices: Hines Retrofit Case Study

    SciTech Connect (OSTI)

    none,

    2013-03-13

    Hines partnered with the Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce energy consumption by at least 30% versus requirements set by Standard 90.1-2004 of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of North America (IESNA) as part of DOEs Commercial Building Partnerships (CBP) Program.

  13. Building America Case Study: Conway Street Apartments, Greenfield, Massachusetts (Fact Sheet), Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Conway Street Apartments Greenfield, Massachusetts PROJECT INFORMATION Project Name: Conway Street Apartments: A Multifamily Deep Energy Retrofit Location: Greenfield, MA Construction: Multifamily (gut rehabili- tation of a vacant school building) Type: Rental apartments Partners: Olive Street Development, zaccheoproperties.com Consortium for Advanced Residential Buildings, carb-swa.com Size: 12 apartments; 1-2 bedroom, 500-1,100 ft 2 Price Range: $900-$1,600/month Date completed: 2014 Climate

  14. Building America Case Study: Raised Ceiling Interior Duct System, New Smyrna, Florida (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Raised Ceiling Interior Duct System New Smyrna, Florida PROJECT INFORMATION Project Name: S.E. Volusia County Habitat for Humanity Zero Energy Ready Home Location: New Smyrna, FL Partners: S. E. Volusia CO Habitat for Humanity Building America Partnership for Improved Residential Construction, ba-pirc.org Building Component: HVAC Application: New and/or retrofit; Single and/or multifamily Year Tested: 2013 Applicable Climate Zone(s): all PERFORMANCE DATA (of the measure alone, not whole house)

  15. Measure Guideline. Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls

    SciTech Connect (OSTI)

    Musunuru, S.; Pettit, B.

    2015-04-30

    This Measure Guideline describes a deep energy enclosure retrofit solution for insulating mass masonry buildings from the interior. It describes the retrofit assembly, technical details, and installation sequence for retrofitting masonry walls. Interior insulation of masonry retrofits might adversely affect the durability of the wall. This guideline includes a review of decision criteria pertinent to retrofitting masonry walls from the interior and the possible risk of freeze-thaw damage.

  16. Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls

    SciTech Connect (OSTI)

    Musunuru, S.; Pettit, B.

    2015-04-01

    This Measure Guideline describes a deep energy enclosure retrofit (DEER) solution for insulating mass masonry buildings from the interior. It describes the retrofit assembly, technical details, and installation sequence for retrofitting masonry walls. Interior insulation of masonry retrofits has the potential to adversely affect the durability of the wall; this document includes a review of decision criteria pertinent to retrofitting masonry walls from the interior and the possible risk of freeze-thaw damage.

  17. Building America Case Study: Supplemental Ductless Mini-Split Heat Pump in the Hot-Humid Climate, Brevard and Volusia Counties, Florida (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Energy Savers [EERE]

    Supplemental Ductless Mini-Split Heat Pump in the Hot-Humid Climate Brevard and Volusia Counties, Florida PROJECT INFORMATION Project Name: Phased Deep Retrofit: Phase II Location: Central Florida Partners: Florida Power & Light, fpl.com Building America Partnership for Improved Residential Construction, ba-pirc.org Building Component: HVAC Application: Retrofit, single-family Year Tested: 2014-2015 Applicable Climate Zone: Hot-humid PERFORMANCE DATA Average home living area: 1,872 ft 2

  18. Building America Technology Solutions for New and Existing Homes: Impact of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate | Department of Energy Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate Building America Technology Solutions for New and Existing Homes: Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate This project investigates the impact of air

  19. Building America Technology Solutions for New and Existing Homes: Impact of

    Energy Savers [EERE]

    Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate, Cocoa, Florida (Fact Sheet) | Department of Energy Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate, Cocoa, Florida (Fact Sheet) Building America Technology Solutions for New and Existing Homes: Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid

  20. Building America Whole-House Solutions for Existing Homes: Evaluation of

    Energy Savers [EERE]

    Missed Energy Saving Opportunity Based on Illinois Home Performance Program Field Data: Homeowner Selected Upgrades vs. Cost-Optimized Solutions, Chicago, Illinois | Department of Energy Missed Energy Saving Opportunity Based on Illinois Home Performance Program Field Data: Homeowner Selected Upgrades vs. Cost-Optimized Solutions, Chicago, Illinois Building America Whole-House Solutions for Existing Homes: Evaluation of Missed Energy Saving Opportunity Based on Illinois Home Performance

  1. Building America Whole-House Solutions for Existing Homes: Inverted Attic

    Energy Savers [EERE]

    Bulkhead for HVAC Ductwork | Department of Energy Inverted Attic Bulkhead for HVAC Ductwork Building America Whole-House Solutions for Existing Homes: Inverted Attic Bulkhead for HVAC Ductwork This occupied test home received a modified truss system to accommodate ductwork within an inverted insulated bulkhead along the attic floor, which saves energy by placing heating, ventilating, and air-conditioning (HVAC) ductwork within the home's thermal boundary. PDF icon Inverted Attic Bulkhead for

  2. Building America Expert Meeting: Delivering Better, Cheaper,...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Better, Cheaper, and Faster Retrofits through Stakeholder-focused Research Building America Expert Meeting: Delivering Better, Cheaper, and Faster Retrofits through...

  3. Building America Webinar: High Performance Space Conditioning...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Air Distribution Retrofit Strategies for Affordable Housing Building America Webinar: High Performance Space Conditioning Systems, Part II - Air Distribution Retrofit Strategies ...

  4. Existing Whole-House Solutions Case Study: Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts

    SciTech Connect (OSTI)

    2013-11-01

    The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. In this project, Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent).

  5. Improving Comfort in Hot-Humid Climates with a Whole-House, Windermere, Florida (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    Comfort in Hot-Humid Climates with a Whole-House Dehumidifier Windermere, Florida PROJECT INFORMATION Project Name: Systems Evaluation at the Cool Energy House Location: Windermere, FL Partners: Southern Traditions Development, http://southerntraditionsdev.com/ Consortium for Advanced Residential Buildings www.carb-swa.com Building Component: HVAC Application: Retrofit, single family Year Tested: 2012 Applicable Climate Zone(s): Hot-humid PERFORMANCE DATA (of the measure alone, not whole house)

  6. Retrofitting Doors on Open Refrigerated Cases

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Retrofitting Doors on Open Refrigerated Cases William Goetzler Navigant Consulting, Inc. wgoetzler@navigant.com (781) 270-8351 April 4, 2013 BBA Refrigeration Project Team Images courtesy of REMIS AMERICA, LLC. 2 | Building Technologies Office eere.energy.gov Technology Overview Image from Investigation of Energy- Efficient Supermarket Display Cases. 2004, Oak Ridge National Laboratory. Background and Motivation * Adding doors to open cases (retrofits) greatly reduces cold air loss - 50-80% load

  7. Target Pilots Energy Efficiency Measures for Broad Rollout in Existing Stores

    SciTech Connect (OSTI)

    2013-03-01

    Target Corporation partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce annual energy consumption by at least 30% versus requirements set by ASHRAE/ANSI/IESNA Standard 90.1-20041 as part of DOEs Commercial Building Partnership (CBP) program.

  8. A simplified model for estimating population-scale energy impacts of building envelope air-tightening and mechanical ventilation retrofits

    SciTech Connect (OSTI)

    Logue, J. M.; Turner, W. J.N.; Walker, I. S.; Singer, B. C.

    2015-07-01

    Changing the air exchange rate of a home (the sum of the infiltration and mechanical ventilation airflow rates) affects the annual thermal conditioning energy. Large-scale changes to air exchange rates of the housing stock can significantly alter the residential sector’s energy consumption. However, the complexity of existing residential energy models is a barrier to the accurate quantification of the impact of policy changes on a state or national level.

  9. Hawaii Clean Energy Initiative Existing Building Energy Efficiency Analysis: November 17, 2009 - June 30, 2010

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7A2-48318 June 2010 Hawaii Clean Energy Initiative Existing Building Energy Efficiency Analysis November 17, 2009 - June 30, 2010 P. Finch and A. Potes Booz Allen Hamilton Honolulu, Hawaii National Renewable Energy Laboratory 1617 Cole Boulevard, Golden, Colorado 80401-3393 303-275-3000 * www.nrel.gov NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Operated by the Alliance for Sustainable Energy, LLC Contract No. DE-AC36-08-GO28308

  10. Housing Archetype Analysis for Home Energy-Efficient Retrofit in the Great Lakes Region

    SciTech Connect (OSTI)

    Kim, S. -K.; Mrozowski, T.; Harrell-Seyburn, A.; Ehrlich, N.; Hembroff, L.; Lieburn, B.; Mazor, M.; McIntyre, A.; Mutton, C.; Parsons, G.; Syal, M. G.; Wilkinson, R.

    2014-09-01

    This project report details activities and results of the "Market Characterization" project undertaken by the Cost Effective Energy Retrofit (CEER) team targeted toward the DOE goal of achieving 30%-50% reduction in existing building energy use. CEER consists of members from the Dow Chemical Company, Michigan State University, Ferris State University, and Habitat for Humanity Kent County. The purpose of this market characterization project was to identify housing archetypes which are dominant within the Great Lakes region and therefore offer significant potential for energy-efficient retrofit research and implementation due to the substantial number of homes possessing similar characteristics. Understanding the characteristics of housing groups referred to as "archetypes" by vintage, style, and construction characteristics can allow research teams to focus their retrofit research and develop prescriptive solutions for those structure types which are prevalent and offer high potential uptake within a region or market.

  11. Cost Effectiveness of Home Energy Retrofits in Pre-Code Vintage Homes in the United States

    SciTech Connect (OSTI)

    Fairey, Philip

    2012-11-01

    This analytical study examines the opportunities for cost-effective energy efficiency and renewable energy retrofits in residential archetypes constructed prior to 1980 (Pre-Code) in fourteen U.S. cities. These fourteen cities are representative of each of the International Energy Conservation Code (IECC) climate zones in the contiguous United States. The analysis is conducted using an in-house version of EnergyGauge USA v.2.8.05 named CostOpt that has been programmed to perform iterative, incremental economic optimization on a large list of residential energy efficiency and renewable energy retrofit measures. The principle objectives of the study are to determine the opportunities for cost effective source energy reductions in this large cohort of existing residential building stock as a function of local climate and energy costs; and to examine how retrofit financing alternatives impact the source energy reductions that are cost effectively achievable.

  12. A simplified model for estimating population-scale energy impacts of building envelope air-tightening and mechanical ventilation retrofits

    SciTech Connect (OSTI)

    Logue, Jennifer M.; Turner, William J. N.; Walker, Iain S.; Singer, Brett C.

    2015-01-19

    Changing the air exchange rate of a home (the sum of the infiltration and mechanical ventilation airflow rates) affects the annual thermal conditioning energy. Large-scale changes to air exchange rates of the housing stock can significantly alter the residential sector's energy consumption. However, the complexity of existing residential energy models is a barrier to the accurate quantification of the impact of policy changes on a state or national level. The Incremental Ventilation Energy (IVE) model developed in this study combines the output of simple air exchange models with a limited set of housing characteristics to estimate the associated change in energy demand of homes. The IVE model was designed specifically to enable modellers to use existing databases of housing characteristics to determine the impact of ventilation policy change on a population scale. The IVE model estimates of energy change when applied to US homes with limited parameterisation are shown to be comparable to the estimates of a well-validated, complex residential energy model.

  13. CBEI: Improving Code Compliance with Change of Occupancy Retrofits - 2015

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Peer Review | Department of Energy Improving Code Compliance with Change of Occupancy Retrofits - 2015 Peer Review CBEI: Improving Code Compliance with Change of Occupancy Retrofits - 2015 Peer Review Presenter: Jennifer Senick, Rutgers View the Presentation PDF icon CBEI: Improving Code Compliance with Change of Occupancy Retrofits - 2015 Peer Review More Documents & Publications Fossil Fuel-Generated Energy Consumption Reduction for New Federal Buildings and Major Renovations of

  14. CBEI: Broker Training - Placing Value on Energy Retrofits - 2015 Peer

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Review | Department of Energy Broker Training - Placing Value on Energy Retrofits - 2015 Peer Review CBEI: Broker Training - Placing Value on Energy Retrofits - 2015 Peer Review Presenter: Susan Wachter, University of Pennsylvania View the Presentation PDF icon CBEI: Broker Training - Placing Value on Energy Retrofits - 2015 Peer Review More Documents & Publications Market Engagement Overview - 2015 BTO Peer Review Commercial Buildings Integration Program Overview - 2015 BTO Peer Review

  15. Advanced Critical Advanced Energy Retrofit Education and Training and

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Credentialing - 2014 BTO Peer Review | Department of Energy Critical Advanced Energy Retrofit Education and Training and Credentialing - 2014 BTO Peer Review Advanced Critical Advanced Energy Retrofit Education and Training and Credentialing - 2014 BTO Peer Review Presenter: David Riley, Penn State Targeting professionals, employers, and education program leaders in selected advanced energy retrofit (AER) project fields (including energy auditors, building operators, energy managers, and

  16. Multifamily Retrofit Tools and Workforce Resources | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Multifamily Retrofit Tools and Workforce Resources Multifamily Retrofit Tools and Workforce Resources The U.S. Department of Energy (DOE) has specific multifamily tools and resources that help alleviate lender and building owner uncertainty about energy upgrade results. Setting the standard for the industry, DOE has the ability to directly retrofit many of the nation's multifamily properties through its deployment programs. Using DOE affiliated multifamily resources means that contractors,

  17. Building America Case Study: Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes PROJECT INFORMATION Construction: New and retrofit Type: Residential Climate Zones: All TEAM MEMBERS Building Science Corporation, buildingscience.com BASF, basf.com The Dow Chemical Company, dow.com Dupont, dupont.com CODE COMPLIANCE International Code Council Evaluation Service AC71-Acceptance Criteria for Foam Plastic Sheathing Panels Used as Water-Resistive Barriers The energy effciency-based fnancial benefts of adding

  18. Building America Case Study: Combustion Safety Simplified Test Protocol, Chicago Illinois, and Minneapolis, Minnesota (Fact Sheet),Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Combustion Safety Simplified Test Protocol Chicago, Illinois, and Minneapolis, Minnesota PROJECT INFORMATION Project Name: Combustion Safety Simplified Test Protocol Location: Chicago, IL, and Minneapolis, MN Partners: Partnership for Advanced Residential Retrofit and NorthernSTAR Building Component: Natural gas water heaters or furnaces in high- performance houses Application: New and/or retrofit; single- and/or multifamily Year Tested: 2015 Applicable Climate Zones: All PERFORMANCE DATA The

  19. CBEI: Lessons Learned from Integrated Retrofits in Small and Medium Sized

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Commercial Buildings - 2015 Peer Review | Department of Energy Lessons Learned from Integrated Retrofits in Small and Medium Sized Commercial Buildings - 2015 Peer Review CBEI: Lessons Learned from Integrated Retrofits in Small and Medium Sized Commercial Buildings - 2015 Peer Review Presenter: Mark Stutman, PSU View the Presentation PDF icon CBEI: Lessons Learned from Integrated Retrofits in Small and Medium Sized Commercial Buildings - 2015 Peer Review More Documents & Publications

  20. CBEI: Packaged Masonry Wall Retrofit Solution for Small and Medium Sized

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Commercial Buildings - 2015 Peer Review | Department of Energy Packaged Masonry Wall Retrofit Solution for Small and Medium Sized Commercial Buildings - 2015 Peer Review CBEI: Packaged Masonry Wall Retrofit Solution for Small and Medium Sized Commercial Buildings - 2015 Peer Review Presenter: Mugdha Mokashi, Bayer Materials View the Presentation PDF icon CBEI: Packaged Masonry Wall Retrofit Solution for Small and Medium Sized Commercial Buildings - 2015 Peer Review More Documents &

  1. Building America Case Study: Selecting Ventilation Systems for Existing Homes (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-12-01

    This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

  2. Building America Whole-House Solutions for New and Existing Homes...

    Broader source: Energy.gov (indexed) [DOE]

    Building America Webinar: New Construction Hybrid-Ductless Heat Pumps Study: Resistance is Futile Building America Webinar: New Construction Hybrid-Ductless Heat Pumps...

  3. Building America Whole-House Solutions for Existing Homes: Multifamily Individual Heating and Ventilation Systems

    Broader source: Energy.gov [DOE]

    The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems in multifamily buildings.

  4. Building America Webinar: May 21, 2014 - | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    - Building America Webinar: May 21, 2014 - This presentation, delivered at the webinar, High Performance Building Enclosures: Part I, Existing Homes, on May 21, 2014, provides strategies for retrofitting exterior foundation insulation without an excavator. PDF icon BA_Webinar_tomschirber_5-21-14.pdf More Documents & Publications Building America Technology Solutions for New and Existing Homes: Excavationless: Exterior-Side Foundation Insulation for Existing Homes (Fact Sheet) Excavationless

  5. Closing Gaps in Modeling Multifamily Retrofits | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Closing Gaps in Modeling Multifamily Retrofits Closing Gaps in Modeling Multifamily Retrofits This presentation was delivered at the U.S. Department of Energy Building America Technical Update meeting on April 29-30, 2013, in Denver, Colorado. PDF icon cq6_closing_gaps_multifamily_dentz.pdf More Documents & Publications Critical Question #6: What are the Challenges and Solutions for Modeling Multifamily Buildings? Building America Webinar: Central Multifamily Water Heating Systems -

  6. Energy Engineering Analysis Program (EEAP) Fort Polk airfield lighting; lighting retrofit

    SciTech Connect (OSTI)

    1993-03-01

    The purpose of this study is to analyze the existing lighting types and levels at three different maintenance hangars (Buildings. No. 4262, No. 4295, and No. 4297) at Fort Polk and to make recommendations for the most economical and preferred new lighting fixtures, arrangements, and method of control. The Life Cycle Cost In Design (LCCID) program was used to determine the Life Cycle Cost (LCC) and Savings to Investment Ratio (SIR) for the analyzed retrofit for a 20 year study life.

  7. Building America Case Study: Initial and Long Term Movement of Cladding Installed Over Exterior Rigid Insulation (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Initial and Long-Term Movement of Cladding Installed Over Exterior Rigid Insulation PROJECT INFORMATION Project Name: Initial and Long-Term Movement of Cladding Installed Over Exterior Rigid Insulation Partners: Building Science Corporation, buildingscience.com The Dow Chemical Company, dow.com James Hardie Building Products, jameshardie.com Building Component: Building envelope component Application: New and/or retrofit; single and/or multi-family Year Research Conducted: 2011 through 2013

  8. ORNL Researchers Study Market Entry Challenges for Building Envelope...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    sector opportunities for commercializing promising sustainable energy technologies. ... potential of a building envelope retrofit system for commercial buildings. ...

  9. Webinar: High Performance Enclosure Strategies: Part I. Existing Homes

    Broader source: Energy.gov [DOE]

    The webinar will focus on specific Building America projects that have studied technical solutions to retrofit building enclosures to improve energy and durability performance. Presenters will...

  10. Boston solar retrofits: studies of solar access and economics

    SciTech Connect (OSTI)

    Shapiro, M.

    1980-11-01

    Studies of solar access and solar retrofit economics are described for residential applications in the City of Boston. The study of solar access was based upon a random sample of 94 buildings; the sample was stratified to ensure a broad geographic representation from the city's various sections. Using available data on the heights and orientations of the sampled structures and surrounding buildings, each building's hourly access to sunlight was computed separately for the roof and south facing walls. These data were then aggregated by broad structural classifications in order to provide general measures of solar access. The second study was a comparative analysis of the economics of several solar heating and hot water systems. An active hot water system, installed using pre-assembled, commercially purchased equipment, was selected as a reference technology. A variety of measures of economic performance were computed for this system, with and without existing tax credits and under various financing arrangements. Next, a number of alternative approaches for solar space and water heating were identified from interviews with individuals and groups involved in solar retrofit projects in the Boston area. The objective was to identify approaches that many of those interviewed believe to be low-cost means of applying solar energy in residential settings. The approaches selected include thermal window covers, wall collectors, bread box water heaters, and sun spaces. Preliminary estimates of the performance of several representative designs were developed and the economics of these designs evaluated.

  11. Cost-Effectiveness of Home Energy Retrofits in Pre-Code Vintage Homes in the United States

    SciTech Connect (OSTI)

    Fairey, P.; Parker, D.

    2012-11-01

    This analytical study examines the opportunities for cost-effective energy efficiency and renewable energy retrofits in residential archetypes constructed prior to 1980 (Pre-Code) in fourteen U.S. cities. These fourteen cities are representative of each of the International Energy Conservation Code (IECC) climate zones in the contiguous U.S. The analysis is conducted using an in-house version of EnergyGauge USA v.2.8.05 named CostOpt that has been programmed to perform iterative, incremental economic optimization on a large list of residential energy efficiency and renewable energy retrofit measures. The principle objectives of the study are as follows: to determine the opportunities for cost effective source energy reductions in this large cohort of existing residential building stock as a function of local climate and energy costs; and to examine how retrofit financing alternatives impact the source energy reductions that are cost effectively achievable.

  12. Building America Webinar: Saving Energy in Multifamily Buildings...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    America Webinar: Saving Energy in Multifamily Buildings This webinar introduced the Building America team Partnership for Advanced Residential Retrofit (PARR) and its...

  13. Assessing 116 Deep Retrofits Across the U.S.

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ASSESSING 116 DEEP RETROFITS ACROSS THE U.S. By: Brennan Less & Iain Walker, LBNL, Residential Building Systems ACI National Home Performance Conference, Detroit, MI, 04/30/2014 Defining a Deep Energy Retrofit- Variable and Flexible 2  Comprehensive upgrades to the building enclosure, heating, cooling and hot water equipment.  Often incorporates appliance and lighting upgrades, plug load reductions, renewable energy and occupant conservation. % Reduction >50% Absolute Reduction

  14. Demonstrating and Deploying Integrated Retrofit Technologies and Solutions

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    - 2014 BTO Peer Review | Department of Energy Demonstrating and Deploying Integrated Retrofit Technologies and Solutions - 2014 BTO Peer Review Demonstrating and Deploying Integrated Retrofit Technologies and Solutions - 2014 BTO Peer Review Presenter: Mark Stutman, Consortium for Building Energy Innovation The Penn State Consortium for Building Energy Innovation focuses on the development, demonstration, and deployment of energy-saving technologies and solutions that can achieve 50% energy

  15. Building America Case Study: Air Leakage and Air Transfer Between Garage and Living Space - Waldorf, Maryland (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Air Leakage and Air Transfer Between Garage and Living Space Waldorf, Maryland PROJECT INFORMATION Project Name: Ventilation Effectiveness Location: Waldorf, MD Partners: Building Science Corporation, buildingscience.com K. Hovnanian Homes, khov.com Building Component: Building and garage ventilation Application: New and retrofit; single and multifamily Year Tested: 2013 Applicable Climate Zone(s): All PERFORMANCE DATA Cost of energy efficiency measure (including labor): $0 if no garage

  16. Building America Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts, Tyler, Texas (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Ventilation System Effectiveness and Tested Indoor Air Quality Impacts Tyler, Texas PROJECT INFORMATION Project Name: Ventilation Effectiveness Location: Tyler, TX Partners: University of Texas, TxAIRE, uttyler.edu/txaire/houses/ Building Science Corporation, buildingscience.com Building Component: Heating, ventilating, and air conditioning (HVAC), whole-building dilution ventilation Application: New and retrofit; single-family and multifamily Year Tested: 2012 Climate Zones: All PERFORMANCE

  17. Building America Whole-House Solutions for Existing Homes: Islip Housing Authority Energy Efficiency Turnover Protocols, Islip, New York

    Broader source: Energy.gov [DOE]

    In this project, ARIES worked with two public housing authorities (PHA) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement at the time when units are refurbished between occupancies. T

  18. Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet), Building America Case Study: Whole-House Solutions for Existing Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    Passive Room-to-Room Air Transfer Fresno, California PROJECT INFORMATION Construction: Retrofit Type: Single-family Builder: GreenEarthEquities (retrofit); http://greenearthequities.com/ Size: 1,621 ft 2 Price range: About $140,000 Date completed: 2011 Climate zone: Mixed-dry PERFORMANCE DATA HERS index: Not available Builder standard practice: Not available Case study house: 1,621 ft 2 With renewables: Not applicable Without renewables: 50.1% Projected annual energy cost savings: Not available

  19. Method for Determining Optimal Residential Energy Efficiency Retrofit Packages

    SciTech Connect (OSTI)

    Polly, B.; Gestwick, M.; Bianchi, M.; Anderson, R.; Horowitz, S.; Christensen, C.; Judkoff, R.

    2011-04-01

    Businesses, government agencies, consumers, policy makers, and utilities currently have limited access to occupant-, building-, and location-specific recommendations for optimal energy retrofit packages, as defined by estimated costs and energy savings. This report describes an analysis method for determining optimal residential energy efficiency retrofit packages and, as an illustrative example, applies the analysis method to a 1960s-era home in eight U.S. cities covering a range of International Energy Conservation Code (IECC) climate regions. The method uses an optimization scheme that considers average energy use (determined from building energy simulations) and equivalent annual cost to recommend optimal retrofit packages specific to the building, occupants, and location. Energy savings and incremental costs are calculated relative to a minimum upgrade reference scenario, which accounts for efficiency upgrades that would occur in the absence of a retrofit because of equipment wear-out and replacement with current minimum standards.

  20. Colorado State Capitol Building Geothermal Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    Retrofit a large scale ground source heat pump system into a historic building located in a built up urban area.

  1. Result of recent weatherization retrofit projects

    SciTech Connect (OSTI)

    Dickinson, J.B.; Lipschutz, R.D.; O'Regan, B.; Wagner, B.S.

    1982-07-01

    Pacific Gas and Electric (PG and E) and the Bonneville Power Administration (BPA) have conducted studies in their respective service areas in order to evaluate the cost-effectiveness of certain conservation retrofits. Twenty houses in Walnut Creek, California, underwent an infiltration reduction program, similar to house doctoring. Ten of these houses also received additional contractor-installed measures. BPA retrofitted 18 houses at its Midway substation in central Washington. Retrofits made to the houses included: attic and crawlspace insulation, foundation sill caulking, storm windows and doors, increased attic ventilation, and infiltration reduction. Energy consumption and weather data were monitored before and after each set of retrofits in both projects. Leakage measurements were made by researchers from the Energy Efficient Buildings Program using blower door fan pressurization, thereby allowing calculation of heating season infiltration rates. An energy use model correlating energy consumption with outside temperature was developed in order to determine improvements to the thermal conductance of the building envelope as a result of the retrofits. Energy savings were calculated based on the results of the energy use model. As a check on these findings, the Computerized Instrumented Residential Audit (CIRA) load calculation program developed at Lawrence Berkeley Laboratory provided a theoretical estimate of the savings resulting from the retrofits. At Midway, storm windows and doors were found to save the most energy. Because the Midway houses were not very leaky at the beginning of the experiment, the infiltration reduction procedures were less effective than expected. In the Walnut Creek project, the infiltration reduction procedures did decrease the leakiness of the test houses, but the effect upon energy savings was not great.

  2. Measured heating system efficiency retrofits in eight manufactured (HUD-code) homes

    SciTech Connect (OSTI)

    Siegel, J.; Davis, B.; Francisco, P.; Palmiter, L.

    1998-07-01

    This report presents the results of field measurements of heating efficiency performed on eight all-electric manufactured homes sited in the Pacific Northwest with forced-air distribution systems. These homes, like more than four million existing manufactured homes in the US, were constructed to thermal specifications that were mandated by the US Department of Housing and Urban Development in 1976. The test protocol compares real-time measurements of furnace energy usage with energy usage during periods when zonal heaters heat the homes to the same internal temperature. By alternating between the furnace and zonal heaters on 2 hour cycles, a short-term coheat test is performed. Additional measurements, including blower door and duct tightness tests, are conducted to measure and characterize the home's tightness and duct leakage so that coheat test results might be linked to other measures of building performance. The testing was done at each home before and after an extensive duct sealing retrofit was performed. The average pre-retrofit system efficiency for these homes was 69%. After the retrofit, the average system efficiency increased to 83%. The average simple payback period for the retrofits ranges from 1 to 5 years in Western Oregon and 1 to 3 years in colder Eastern Oregon.

  3. Viscous-Fluid-Spring Damper Retrofit of a Steel Moment Frame Structure

    SciTech Connect (OSTI)

    Hussain, Saif; Van Benschoten, Paul; Al Satari, Mohamed; Lin, Silian

    2008-07-08

    The subject building is a peculiar pre-Northridge steel moment resisting frame building. Upon investigating the existing lateral resisting system, numerous significant deficiencies were identified; inherent lack of redundancy, poor geometry and inadequate stiffness of the lateral resisting system. All of which resulted in an extremely soft 5-story structure with a primary torsional mode of vibration at T{sub 1} = 5.46 s. Significant structural modifications were deemed necessary to meet the 'life-safety' performance objective as outlined in rehabilitation standards such as ASCE 41. Both increased stiffness and damping were required to adequately retrofit the building. Furthermore, adjacent building separation as well as deformation compatibility issues needed to be addressed and resolved. A three-dimensional computer model of the building was created using ETABS mathematically simulating the building's dynamic characteristics in its current condition. Multiple seismic retrofit systems were investigated such as Buckling Restrained Braced Frames (BRBF's). However, based on the performance effectiveness and constructability of the retrofit schemes studied, the Viscous-Fluid-Spring Damper (VFSD) system was proposed as the 'optimum' solution for the building. The VFSD, was chosen because it combines the relatively compact size and minimally invasive constructability with the required properties (an elastomeric spring in parallel with a nonlinear velocity dependent viscous damper). A site-specific response spectrum was developed for the Design Basis Earthquake (DBE, 475 year return period) event, and three pairs of representative earthquake horizontal ground motion time-histories were scaled to match this DBE. The proposed scheme reduced the building maximum inter-story drift ratio from 5.4% to about 1%. Similarly, the maximum roof displacement was reduced by about 70% (23'' to 7'')

  4. Building America Webinar: High Performance Space Conditioning Systems, Part

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    II - Air Distribution Retrofit Strategies for Affordable Housing | Department of Energy Air Distribution Retrofit Strategies for Affordable Housing Building America Webinar: High Performance Space Conditioning Systems, Part II - Air Distribution Retrofit Strategies for Affordable Housing Jordan Dentz, Advanced Residential Integrated Energy Solutions (ARIES), and Francis Conlin, High Performance Building Solutions, Inc., presenting Air Distribution Retrofit Strategies for Affordable Housing.

  5. OpenStudio Enhancements for Whole-Building Daylighting, Airflow, and Energy Modeling Leveraging Interoperable Building Information Modeling Data- 2014 BTO Peer Review

    Broader source: Energy.gov [DOE]

    Presenter: John Messner, the Pennsylvania State University Consortium for Building Energy Innovation Energy modeling often is inconsistently applied in the small- and medium-sized commercial building (SMSCB) market, in part because existing models are either too complex relative to the project size or because models are not interoperable with other retrofit design tools.

  6. Building America Whole-House Solutions for Existing Homes: 56th...

    Energy Savers [EERE]

    America Whole-House Solutions for Existing Homes: 56th and Walnut: A Philly Gut Rehab Development In this project, CPM partnered with the Consortium for Advanced Residential...

  7. Evaluating Energy Savings in All-Electric Public Housing in the Pacific Northwest (Fact Sheet), Building America Case Study: Whole-House Solutions for New and Existing Homes, Building Technologies Office (BTO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and Existing Homes Evaluating Energy Savings in All-Electric Public Housing in the Pacific Northwest Tacoma, Washington PROJECT INFORMATION New Construction: Phase 7 Retrofit Existing: Phases 1-6 Type: Multifamily, affordable Builder: Walsh Construction Size: Phases 1-7, 975 ft 2 to 1,109 ft 2 Years Completed: Phase 7, 2010; Phases 1-6, 2003-2006 Climate Zone: Marine PERFORMANCE DATA Billing analysis savings-Phase 7 versus Phases 1-6: 1,400-3,044 kWh/year Phases 1-6 projected energy savings and

  8. Expert Meeting Report: Interior Insulation Retrofit of Mass Masonry Wall Assemblies

    SciTech Connect (OSTI)

    Ueno, K.; Van Straaten, R.

    2012-02-01

    The Building Science Consortium held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011 at the Westford Regency Hotel in Westford, MA. This report outlines the extensive information that was presented on assessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce such risks.

  9. Expert Meeting Report. Interior Insulation Retrofit of Mass Masonry Wall Assemblies

    SciTech Connect (OSTI)

    Ueno, K.; Van Straaten, R.

    2012-02-01

    The Building Science Consortium held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011, at the Westford Regency Hotel in Westford, MA. This report outlines the extensive information that was presented on assessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce such risks.

  10. Strategy Guideline: Quality Management in Existing Homes - Cantilever Floor Example

    SciTech Connect (OSTI)

    Taggart, J.; Sikora, J.; Wiehagen, J.; Wood, A.

    2011-12-01

    This guideline is designed to highlight the QA process that can be applied to any residential building retrofit activity. The cantilevered floor retrofit detailed in this guideline is included only to provide an actual retrofit example to better illustrate the QA activities being presented.

  11. A New Campus Building on Efficiency: University of California (UC) Merced Case Study

    SciTech Connect (OSTI)

    2013-03-01

    The University of California (UC), Merced partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit two existing buildings to reduce energy consumption by at least 30% as part of DOEs Commercial Buildings Partnerships (CBP) Program.

  12. Building America Case Study: Field Performance of Inverter-Driven Heat Pumps in Cold Climates - Connecticut, Massachusetts, and Vermont (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Performance of Inverter-Driven Heat Pumps in Cold Climates Connecticut, Massachusetts, and Vermont PROJECT INFORMATION Project Name: Field Performance of Inverter-Driven Heat Pumps in Cold Climates Location: CT, MA, and VT Partners: Efficiency Vermont, efficiencyvermont.com Consortium for Advanced Residential Buildings, carb-swa.com Building Component: Heating, ventilating, and air conditioning Application: New and retrofit; single- family and multifamily Year Tested: 2013-2014 Climate Zone(s):

  13. Building America Case study: Advanced Controls Improve Performance of Combination Space and Water Heating Systems, Minneapolis, Minnesota (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Controls Improve Performance of Combination Space- and Water-Heating Systems Minneapolis, Minnesota PROJECT INFORMATION Combined Space and Water Heating: Next Steps to Improved Performance Location: Minneapolis, MN Partners: University of Minnesota and The Energy Conservatory Center for Energy and Environment, mncee.org NorthernSTAR Building America Partnership Building Component: Space conditioning and water heating Application: New and retrofit; single-family Year Tested: 2011-2014 Applicable

  14. Actual and Estimated Energy Savings Comparison for Deep Energy Retrofits in the Pacific Northwest

    SciTech Connect (OSTI)

    Blanchard, Jeremy; Widder, Sarah H.; Giever, Elisabeth L.; Baechler, Michael C.

    2012-10-01

    Seven homes from the Pacific Northwest were selected to evaluate the differences between estimated and actual energy savings achieved from deep energy retrofits. The energy savings resulting from these retrofits were estimated, using energy modeling software, to save at least 30% on a whole-house basis. The modeled pre-retrofit energy use was trued against monthly utility bills. After the retrofits were completed, each of the homes was extensively monitored, with the exception of one home which was monitored pre-retrofit. This work is being conducted by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. This work found many discrepancies between actual and estimated energy savings and identified the potential causes for the discrepancies. The differences between actual energy use and modeled energy use also suggest improvements to improve model accuracy. The difference between monthly whole-house actual and estimated energy savings ranged from 75% more energy saved than predicted by the model to 16% less energy saved for all the monitored homes. Similarly, the annual energy savings difference was between 36% and -14%, which was estimated based on existing monitored savings because an entire year of data is not available. Thus, on average, for all six monitored homes the actual energy use is consistently less than estimates, indicating home owners are saving more energy than estimated. The average estimated savings for the eight month monitoring period is 43%, compared to an estimated savings average of 31%. Though this average difference is only 12%, the range of inaccuracies found for specific end-uses is far greater and are the values used to directly estimate energy savings from specific retrofits. Specifically, the monthly post-retrofit energy use differences for specific end-uses (i.e., heating, cooling, hot water, appliances, etc.) ranged from 131% under-predicted to 77% over-predicted by the model with respect to monitored energy use. Many of the discrepancies were associated with occupant behavior which influences energy use, dramatically in some cases, actual versus modeled weather differences, modeling input limitations, and complex homes that are difficult to model. The discrepancy between actual and estimated energy use indicates a need for better modeling tools and assumptions. Despite the best efforts of researchers, the estimated energy savings are too inaccurate to determine reliable paybacks for retrofit projects. While the monitored data allows researchers to understand why these differences exist, it is not cost effective to monitor each home with the level of detail presented here. Therefore an appropriate balance between modeling and monitoring must be determined for more widespread application in retrofit programs and the home performance industry. Recommendations to address these deficiencies include: (1) improved tuning process for pre-retrofit energy use, which currently utilized broad-based monthly utility bills; (2) developing simple occupant-based energy models that better address the many different occupant types and their impact on energy use; (3) incorporating actual weather inputs to increase accuracy of the tuning process, which uses utility bills from specific time period; and (4) developing simple, cost-effective monitoring solutions for improved model tuning.

  15. Lighting Retrofit Improving Visibility, Saving Energy | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Retrofit Improving Visibility, Saving Energy Lighting Retrofit Improving Visibility, Saving Energy August 27, 2010 - 10:05am Addthis New LED lighting fixtures (right) emit a whiter light than existing high-pressure sodium cobra head streetlights (left) and don't spill light onto nearby houses. | Photos courtesy of the City of Muscatine New LED lighting fixtures (right) emit a whiter light than existing high-pressure sodium cobra head streetlights (left) and don't spill light onto

  16. Department of Energy Recognizes Cummins for Deep Energy Retrofit at

    Office of Environmental Management (EM)

    Jamestown Engine Plant | Department of Energy Cummins for Deep Energy Retrofit at Jamestown Engine Plant Department of Energy Recognizes Cummins for Deep Energy Retrofit at Jamestown Engine Plant November 6, 2014 - 9:05am Addthis NEWS MEDIA CONTACT (202) 586-4940 JAMESTOWN, N.Y. - As a part of the Administration's effort to increase energy efficiency nationwide through the Better Buildings, Better Plants Challenge, the Energy Department today recognized Cummins Inc., for demonstrating

  17. Deep Energy Retrofits & State Applications

    Broader source: Energy.gov [DOE]

    This presentation, given through the DOE's Technical Assitance Program (TAP), provides information on Deep Energy Retrofits & State Applications

  18. Residential Retrofit Design Guide Overview

    Broader source: Energy.gov [DOE]

    This webinar covered the Residential Retrofit Program Design Guide and its elements, including assess, plan, implement, and evaluate.

  19. Protocol for Maximizing Energy Savings and Indoor Environmental Quality Improvements when Retrofitting Apartments

    SciTech Connect (OSTI)

    Noris, Federico; Delp, William W.; Vermeer, Kimberly; Adamkiewicz, Gary; Singer, Brett C.; Fis, William J.

    2012-06-18

    The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

  20. Protocol for maximizing energy savings and indoor environmental quality improvements when retrofitting apartments

    SciTech Connect (OSTI)

    Noris, Federico; Delp, William W.; Vermeer, Kimberly; Adamkiewicz, Gary; Singer, Brett C.; Fisk, William J.

    2013-06-01

    The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

  1. Low-E Retrofit Demonstration and Educational Program

    SciTech Connect (OSTI)

    Culp, Thomas D; Wiehagen, Joseph; Drumheller, S Craig; Siegel, John; Stratmoen, Todd

    2013-11-16

    The objective of this project was to demonstrate the capability of low-emissivity (low-E) storm windows / panels and low-E retrofit glazing systems to significantly and cost effectively improve the energy efficiency of both existing residential and commercial buildings. The key outcomes are listed below: RESIDENTIAL CASE STUDIES: (a) A residential case study in two large multifamily apartment buildings in Philadelphia showed a substantial 18-22% reduction in heating energy use and a 9% reduction in cooling energy use by replacing old clear glass storm windows with modern low-E storm windows. Furthermore, the new low-E storm windows reduced the overall apartment air leakage by an average of 10%. (b) Air leakage testing on interior low-E panels installed in a New York City multifamily building over windows with and without AC units showed that the effective leakage area of the windows was reduced by 77-95%. (c) To study the use of low-E storm windows in a warmer mixed climate with a balance of both heating and cooling, 10 older homes near Atlanta with single pane windows were tested with three types of exterior storm windows: clear glass, low-E glass with high solar heat gain, and low-E glass with lower solar heat gain. The storm windows significantly reduced the overall home air leakage by an average of 17%, or 3.7 ACH50. Considerably high variability in the data made it difficult to draw strong conclusions about the overall energy usage, but for heating periods, the low-E storm windows showed approximately 15% heating energy savings, whereas clear storm windows were neutral in performance. For cooling periods, the low-E storm windows showed a wide range of performance from 2% to over 30% cooling energy savings. Overall, the study showed the potential for significantly more energy savings from using low-E glass versus no storm window or clear glass storm windows in warmer mixed climates, but it is difficult to conclusively say whether one type of low-E performed better than the other. COMMERCIAL CASE STUDIES: (a) A 12-story office building in Philadelphia was retrofitted by adding a double-pane low-E insulating glass unit to the existing single pane windows, to create a triple glazed low-E system. A detailed side-by-side comparison in two pairs of perimeter offices facing north and east showed a 39-60% reduction in heating energy use, a 9-36% reduction in cooling energy use, and a 10% reduction in peak electrical cooling demand. An analysis of utility bills estimated the whole building heating and cooling energy use was reduced by over 25%. Additionally, the retrofit window temperatures were commonly 20 degrees warmer on winter days, and 10-20 degrees cooler on summer days, leading to increased occupant comfort. (b) Two large 4-story office buildings in New Jersey were retrofitted with a similar system, but using two low-E coatings in the retrofit system. The energy savings are being monitored by a separate GPIC project; this work quantified the changes in glass surface temperatures, thermal comfort, and potential glass thermal stress. The low-E retrofit panels greatly reduced daily variations in the interior window surface temperatures, lowering the maximum temperature and raising the minimum temperature by over 20F compared to the original single pane windows with window film. The number of hours of potential thermal discomfort, as measured by deviation between mean radiant temperature and ambient air temperature by more than 3F, were reduced by 93 percent on the south orientation and over two-thirds on the west orientation. Overall, the low-E retrofit led to substantially improved occupant comfort with less periods of both overheating and feeling cold. (c) No significant thermal stress was observed in the New Jersey office building test window when using the low-E retrofit system over a variety of weather conditions. The surface temperature difference only exceeded 10F (500 psi thermal stress) for less than 1.5% of the monitored time, and in all cases, the maximum surface temperature difference never exceeded 35F (1,75

  2. Building America Case Study: Excavationless Exterior-Side Foundation Insulation for Existing Homes, Minneapolis, Minnesota (Fact Sheet)

    SciTech Connect (OSTI)

    NorthernSTAR

    2014-09-01

    Building science research supports installing exterior (soil side) foundation insulation as the optimal method to enhance the hygrothermal performance of new homes. With exterior foundation insulation, water management strategies are maximized while insulating the basement space and ensuring a more even temperature at the foundation wall. However, such an approach can be very costly and disruptive when applied to an existing home, requiring deep excavation around the entire house. The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with a liquid insulating foam. The team was able to excavate a continuous 4" wide by 4' to 5' deep trench around the entire house, 128 linear feet, except for one small part under the stoop that was obstructed with concrete debris. The combination pressure washer and vacuum extraction technology also enabled the elimination of large trenches and soil stockpiles normally produced by backhoe excavation. The resulting trench was filled with liquid insulating foam, which also served as a water-control layer of the assembly. The insulation was brought above grade using a liquid foam/rigid foam hybrid system and terminated at the top of the rim joist. Cost savings over the traditional excavation process ranged from 23% to 50%. The excavationless process could result in even greater savings since replacement of building structures, exterior features, utility meters, and landscaping would be minimal or non-existent in an excavationless process.

  3. Measured Cooling Performance and Potential for Buried Duct Condensation in a 1991 Central Florida Retrofit Home

    SciTech Connect (OSTI)

    Chasar, Dave; Withers, Charles R.

    2013-02-01

    FSEC conducted energy performance monitoring of two existing residences in Central Florida that were undergoing various retrofits. These homes were occupied by FSEC researchers and were fully instrumented to provide detailed energy, temperature, and humidity measurements. The data provided feedback about the performance of two levels of retrofit in two types of homes in a hot-humid climate. This report covers a moderate-level retrofit and includes two years of pre-retrofit data to characterize the impact of improvements. The other home is a 'deep energy retrofit' (detailed in a separate report) that has performed at near zero energy with a photovoltaic (PV) system and extensive envelope improvements.

  4. Retrofit Financial Analysis Tool

    Office of Energy Efficiency and Renewable Energy (EERE)

    The Street and Parking Facility Lighting Retrofit Financial Analysis Tool was developed by a partnership of the DOE Municipal Solid-State Street Lighting Consortium, the Clinton Climate Initiative (CCI)/C40, and the Federal Energy Management Program (FEMP), for the financial analysis of retrofitting street and parking facility lighting with more efficient alternatives. Property owners, city and other government agencies, utilities, and energy efficiency organizations can use this tool to compute annualized energy and energy-cost savings, maintenance savings, greenhouse gas reductions, net present value, and simple payback associated with potential lighting upgrades.

  5. Text-Alternative Version of Building America Webinar: Solutions for

    Energy Savers [EERE]

    Combustion Safety in Existing Homes | Department of Energy Solutions for Combustion Safety in Existing Homes Text-Alternative Version of Building America Webinar: Solutions for Combustion Safety in Existing Homes Solutions for Combustion Safety in Existing Homes 12/16/15 Speakers Larry Brand, Research and Development Manager at the Gas Technology Institute and the Partnership for Advanced Residential Retrofit (PARR) David Bohac, Director of Research with the Center for Energy and Environment

  6. Rule to Support Increased Energy Measurement and Efficient Building...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    for new and retrofitted federal buildings that are certified by private sector green building certification systems. The use of green building rating systems advances...

  7. CBEI - Collaborative Approaches for Integrated Energy Retrofits

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    CBEI - Collaborative Approaches for Integrated Energy Retrofits 2015 Building Technologies Office Peer Review John Messner, jmessner@engr.psu.edu Charles and Elinor Matts Professor of Architectural Engineering CBEI - The Pennsylvania State University Project Summary Timeline: Start date: February 1, 2013 Planned end date: April 30, 2015 Key Milestones: 1. Three work sessions in collaborative workspace (April 30, 2014) 2. Work with 5 project teams in collaborative workspaces (April 30, 2015) 3.

  8. Greenbuilt Retrofit Test House Final Report

    SciTech Connect (OSTI)

    Sparn, B.; Hudon, K.; Earle, L.; Booten, C.; Tabares-Velasco, P. C.; Barker, G.; Hancock, C. E.

    2014-06-01

    The Greenbuilt house, is an all-electric, 1980's era home in the eastern Sacramento suburb of Fair Oaks that was retrofit by Greenbuilt Construction as part of Sacramento Municipal Utility District's (SMUD) Energy Efficient Remodel Demonstration (EERD) Program. The project was a joint effort between the design-build team at Greenbuilt Construction, led by Jim Bayless, SMUD and their project manager Mike Keesee, and the National Renewable Energy Laboratory (NREL). The goal of the Energy Efficient Remodel Demonstration program is to work with local builders to renovate homes with cost-effective energy efficient retrofit measures. The homes remodeled under the EERD program are intended to showcase energy efficient retrofit options for homeowners and other builders. The Greenbuilt house is one of five EERD projects that NREL has supported. NREL's main role in these projects is to provide energy analysis and to monitor the home's performance after the retrofit to verify that the energy consumption is in line with the modeling predictions. NREL also performed detailed monitoring on the more innovative equipment included in these remodels, such as an add-on heat pump water heater.

  9. Residential Retrofit Program Design Guide | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Residential Retrofit Program Design Guide Residential Retrofit Program Design Guide Residential Retrofit Program Design Guide. PDF icon Residential Retrofit Program Design Guide...

  10. Low-to-No Cost Strategy for Energy Efficiency in Public Buildings |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Low-to-No Cost Strategy for Energy Efficiency in Public Buildings Low-to-No Cost Strategy for Energy Efficiency in Public Buildings This webinar covered how to make existing buildings more energy efficient. Transcript PDF icon Presentation More Documents & Publications Effective O&M Policy in Public Buildings Preparing for the Arrival of Electric Vehicle Quality Assurance for Residential Retrofit Programs

  11. Predicted Versus Actual Savings for a Low-Rise Multifamily Retrofit in Boulder, Colorado

    SciTech Connect (OSTI)

    Arena, L.; Williamson, J.

    2013-11-01

    To determine the most cost-effective methods of improving buildings, accurate analysis and prediction of the energy use of existing buildings is essential. However, multiple studies confirm that analysis methods tend to over-predict energy use in poorly insulated, leaky homes and thus, the savings associated with improving those homes. In NREL's report titled 'Assessing and Improving the Accuracy of Energy Analysis of Residential Buildings,' researchers propose a method for improving the accuracy of residential energy analysis methods. A key step in this process involves the comparisons of predicted versus metered energy use and savings. In support of this research need, CARB evaluated the retrofit of a multifamily building in Boulder, CO. The updated property is a 37 unit, 2 story apartment complex built in 1950, which underwent renovations in early 2009 to bring it into compliance with Boulder, CO's SmartRegs ordinance. Goals of the study were to: 1) evaluate predicted versus actual savings due to the improvements, 2) identify areas where the modeling assumptions may need to be changed, and 3) determine common changes made by renters that would negatively impact energy savings. In this study, CARB seeks to improve the accuracy of modeling software while assessing retrofit measures to specifically determine which are most effective for large multifamily complexes in the cold climate region. Other issues that were investigated include the effects of improving building efficiency on tenant comfort, the impact on tenant turnover rates, and the potential market barriers for this type of community scale project.

  12. Appraisers Project Plan: Wireless Controls and Retrofit LED Lighting Demonstration

    Broader source: Energy.gov [DOE]

    Appraisers Project Plan: Wireless Controls and Retrofit LED Lighting Demonstration Measurement and Verification Report This report details the measurement and verification tools and methods used to evaluate the effectiveness of wireless lighting controls and LED lighting at the Appraisers Building, a federal office building in San Francisco, CA.

  13. Expert Meeting Report: Retrofit Implementation - A Neighborhood at a Time

    SciTech Connect (OSTI)

    Griffiths, D.

    2012-04-01

    This report provides information about a Building America expert meeting hosted by research team Consortium for Advanced Residential Buildings on October 25, 2011, in New York City. The meeting discussed several community residential retrofit projects underway across the United States, and included representatives from utilities, energy program implementation firms, affordable housing agencies, and the financing industry.

  14. Expert Meeting Report: Retrofit Implementation - A Neighborhood at a Time

    SciTech Connect (OSTI)

    Griffiths, Dianne

    2012-04-01

    This report provides information about a Building America expert meeting hosted by research team Consortium for Advanced Residential Buildings (CARB) on October 25, 2011, in New York City. The meeting discussed several community residential retrofit projects underway across the United States, and included representatives from utilities, energy program implementation firms, affordable housing agencies, and the financing industry.

  15. Byggmeister Test Home. Analysis and Initial Results of Cold Climate Wood-Framed Home Retrofit

    SciTech Connect (OSTI)

    Gates, C.

    2013-01-01

    BSC seeks to further the energy efficiency market for New England area retrofit projects by supporting projects that are based on solid building science fundamentals that will benefit the homeowner through a combination of energy savings, improved durability, and occupant comfort. This report describes a deep retrofit project of a two-family wood-framed home in Belmont, Massachusetts, and examines the retrofit measures for the enclosure amd mechanical systems and reviews the decision-making process that took place during planning.

  16. Balancing Hydronic Systems in Multifamily Buildings

    SciTech Connect (OSTI)

    Ruch, Russell; Ludwig, Peter; Maurer, Tessa

    2014-07-01

    In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution, and controls. The imbalance leads to tenant discomfort, higher energy use intensity, and inefficient building operation. This research, conducted by Building America team Partnership for Advanced Residential Retrofit, explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1F to 15.5F.

  17. Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

    SciTech Connect (OSTI)

    Wang, Weimin; Katipamula, Srinivas; Ngo, Hung; Underhill, Ronald M.; Taasevigen, Danny J.; Lutes, Robert G.

    2013-07-31

    The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energys (DOEs) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

  18. NREL: Buildings Research - News Release Archives

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    9 November 9, 2009 New Recovery Through Retrofit Plan Expands Residential Funding Opportunities The new Recovery Through Retrofit Plan will broaden opportunities for residential building projects. Archives Current News | 2006

  19. Short-Term Test Results. Transitional Housing Energy Efficiency Retrofit in the Hot Humid Climate

    SciTech Connect (OSTI)

    Sutherland, K.

    2013-02-01

    This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30%-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

  20. Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot-Humid Climate

    SciTech Connect (OSTI)

    Sutherland, K.; Martin, E.

    2013-02-01

    This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.