Sample records for retrofit equipment occurs

  1. Compressed Air System Analysis and Retrofit for Energy Savings

    E-Print Network [OSTI]

    Harding, C.; Nutter, D.

    2014-01-01T23:59:59.000Z

    several actions including piping retrofits, equipment upgrades, pressure control changes, and compressor retrofits....

  2. Standard Measurement & Verification Plan for Lighting Equipment Retrofit or Replacement Projects

    SciTech Connect (OSTI)

    Richman, Eric E.

    2009-11-04T23:59:59.000Z

    This document provides a framework for a standard Measurement and Verification (M&V) plan for lighting projects. It was developed to support cost-effective retrofits (partial and complete replacements) of lighting systems and is intended to provide a foundation for an M&V plan for a lighting retrofit utilizing a "best practice" approach, and to provide guidance to site owners, contractors, and other involved organizations on what is essential for a robust M&V plan for lighting projects. This document provides examples of appropriate elements of an M&V plan, including the calculation of expected energy savings. The standard M&V plan, as provided, also allows for consistent comparison with other similar lighting projects. Although intended for lighting retrofit applications, M&V plans developed per this framework document may also be used for other non-lighting technology retrofits and new installations.

  3. Method for Determining Optimal Residential Energy Efficiency Retrofit Packages

    SciTech Connect (OSTI)

    Polly, B.; Gestwick, M.; Bianchi, M.; Anderson, R.; Horowitz, S.; Christensen, C.; Judkoff, R.

    2011-04-01T23:59:59.000Z

    Businesses, government agencies, consumers, policy makers, and utilities currently have limited access to occupant-, building-, and location-specific recommendations for optimal energy retrofit packages, as defined by estimated costs and energy savings. This report describes an analysis method for determining optimal residential energy efficiency retrofit packages and, as an illustrative example, applies the analysis method to a 1960s-era home in eight U.S. cities covering a range of International Energy Conservation Code (IECC) climate regions. The method uses an optimization scheme that considers average energy use (determined from building energy simulations) and equivalent annual cost to recommend optimal retrofit packages specific to the building, occupants, and location. Energy savings and incremental costs are calculated relative to a minimum upgrade reference scenario, which accounts for efficiency upgrades that would occur in the absence of a retrofit because of equipment wear-out and replacement with current minimum standards.

  4. NIPSCO- Existing Facility Retrofit Rebate Program

    Broader source: Energy.gov [DOE]

    Northern Indiana Public Service Corporation (NIPSCO) offers incentives to commercial, industrial, nonprofit, government, and institutional customers for replacing or retrofitting equipment or...

  5. Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics

    E-Print Network [OSTI]

    Graham, E. L.

    1980-01-01T23:59:59.000Z

    Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

  6. Deep Residential Retrofits in East Tennessee

    SciTech Connect (OSTI)

    Boudreaux, Philip R [ORNL; Hendrick, Timothy P [ORNL; Christian, Jeffrey E [ORNL; Jackson, Roderick K [ORNL

    2012-04-01T23:59:59.000Z

    Executive Summary Oak Ridge National Laboratory (ORNL) is furthering residential energy retrofit research in the mixed-humid climate of East Tennessee by selecting 10 homes and guiding the homeowners in the energy retrofit process. The homeowners pay for the retrofits, and ORNL advises which retrofits to complete and collects post-retrofit data. This effort is in accordance with the Department of Energy s Building America program research goal of demonstrating market-ready energy retrofit packages that reduce home energy use by 30 50%. Through this research, ORNL researchers hope to understand why homeowners decide to partake in energy retrofits, the payback of home energy retrofits, and which retrofit packages most economically reduce energy use. Homeowner interviews help the researchers understand the homeowners experience. Information gathered during the interviews will aid in extending market penetration of home energy retrofits by helping researchers and the retrofit industry understand what drives homeowners in making positive decisions regarding these retrofits. This report summarizes the selection process, the pre-retrofit condition, the recommended retrofits, the actual cost of the retrofits (when available), and an estimated energy savings of the retrofit package using EnergyGauge . Of the 10 households selected to participate in the study, only five completed the recommended retrofits, three completed at least one but no more than three of the recommended retrofits, and two households did not complete any of the recommended retrofits. In the case of the two homes that did none of the recommended work, the pre-retrofit condition of the homes and the recommended retrofits are reported. The five homes that completed the recommended retrofits are monitored for energy consumption of the whole house, appliances, space conditioning equipment, water heater, and most of the other circuits with miscellaneous electric loads (MELs) and lighting. Thermal comfort is also monitored, with temperature and humidity measured in all conditioned zones, attics, crawlspaces, and unconditioned basements. In some homes, heat flux transducers are installed on the basement walls to help determine the insulating qualities of the technologies and practices. EnergyGauge is used to estimate the pre-retrofit and post-retrofit home energy rating system (HERS) index and reduction in energy consumption and energy bill. In a follow-up report, data from the installed sensors will be presented and analyzed as well as a comparison of the post-retrofit energy consumption of the home to the EnergyGauge model of the post-retrofit home. Table ES1 shows the retrofits that were completed at the eight households where some or all of the recommended retrofits were completed. Home aliases are used to keep the homeowners anonymous. Some key findings of this study thus far are listed as follows. Some homeowners (50%) are not willing to spend the money to reach 30 50% energy savings. Quality of retrofit work is significantly variable among contractors which impact the potential energy savings of the retrofit. Challenges exist in defining house volume and floor area. Of the five homes that completed all the recommended retrofits, energy bill savings was not the main driver for energy retrofits. In no case were the retrofits cost neutral given a 15 year loan at 7% interest for the retrofit costs.

  7. Strengthening Building Retrofit Markets

    SciTech Connect (OSTI)

    Templeton, Mary [Michigan Saves; Jackson, Robert [Michigan Energy Office

    2014-04-15T23:59:59.000Z

    The Business Energy Financing (BEF) program offered commercial businesses in Michigan affordable financing options and other incentives designed to support energy efficiency improvements. We worked through partnerships with Michigan utilities, lenders, building contractors, trade associations, and other community organizations to offer competitive interest rates and flexible financing terms to support energy efficiency projects that otherwise would not have happened. The BEF program targeted the retail food market, including restaurants, grocery stores, convenience stores, and wholesale food vendors, with the goal of achieving energy efficiency retrofits for 2 percent of the target market. We offered low interest rates, flexible payments, easy applications and approval processes, and access to other incentives and rebates. Through these efforts, we sought to help customers strive for energy savings retrofits that would save 20 percent or more on their energy use. This program helped Michigan businesses reduce costs by financing energy efficient lighting, heating and cooling systems, insulation, refrigeration, equipment upgrades, and more. Businesses completed the upgrades with the help of our authorized contractors, and, through our lending partners, we provided affordable financing options.

  8. Energy Efficient Retrofits and Green Building Practices

    E-Print Network [OSTI]

    Rahman, M.

    2010-01-01T23:59:59.000Z

    are reduced, making the business more profitable and competitive. ? Comfort levels are increased for staff, which can improve productivity. ? Increase life of the equipment, provide trouble free operation and minimize equipment down time ? Energy usage.... Before Retrofits; The central chiller plant was equipped with 4 Chillers each Chiller was provided with Multi Stage Centrifugal Compressor. Each Chiller was connected to an individual Radiator for Heat Rejection, each Radiator was provided with 4...

  9. Retrofit Air Preheat Economics

    E-Print Network [OSTI]

    Goolsbee, J. A.

    1981-01-01T23:59:59.000Z

    Retrofit air preheat systems are the most reliable and efficient means to effect significant energy conservation for large existing industrial furnaces. Units can be quickly installed without a lengthy shutdown, and the furnace efficiency can...

  10. Building America Webinar: Retrofitting Central Space Conditioning...

    Energy Savers [EERE]

    Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings - Steam Systems, Retrofit Measure Packages, Hydronic Systems Building America Webinar:...

  11. Greenbuilt Retrofit Test House Final Report

    SciTech Connect (OSTI)

    Sparn, B.; Hudon, K.; Earle, L.; Booten, C.; Tabares-Velasco, P. C.; Barker, G.; Hancock, C. E.

    2014-06-01T23:59:59.000Z

    The Greenbuilt house, is an all-electric, 1980's era home in the eastern Sacramento suburb of Fair Oaks that was retrofit by Greenbuilt Construction as part of Sacramento Municipal Utility District's (SMUD) Energy Efficient Remodel Demonstration (EERD) Program. The project was a joint effort between the design-build team at Greenbuilt Construction, led by Jim Bayless, SMUD and their project manager Mike Keesee, and the National Renewable Energy Laboratory (NREL). The goal of the Energy Efficient Remodel Demonstration program is to work with local builders to renovate homes with cost-effective energy efficient retrofit measures. The homes remodeled under the EERD program are intended to showcase energy efficient retrofit options for homeowners and other builders. The Greenbuilt house is one of five EERD projects that NREL has supported. NREL's main role in these projects is to provide energy analysis and to monitor the home's performance after the retrofit to verify that the energy consumption is in line with the modeling predictions. NREL also performed detailed monitoring on the more innovative equipment included in these remodels, such as an add-on heat pump water heater.

  12. Deep Energy Retrofits & State Applications

    Broader source: Energy.gov [DOE]

    This presentation, given through the DOE's Technical Assitance Program (TAP), provides information on Deep Energy Retrofits & State Applications

  13. Passive retrofits for Navy housing

    SciTech Connect (OSTI)

    Hibbert, R.; Miles, C.; Jones, R.; Peck, C.; Anderson, J.; Jacobson, V.; Dale, A.M.

    1985-01-01T23:59:59.000Z

    A project to assess and initiate passive solar energy retrofits to US Navy family housing is described. The current data base for Navy housing (ECOP), and its enhancement for passive solar purposes options proposed for Navy housing are explained. The analysis goals and methods to evaluate the retrofits are discussed. An educational package to explain the retrofits is described.

  14. Best practices guide for residential HVAC Retrofits

    SciTech Connect (OSTI)

    Walker, Iain S.

    2003-08-11T23:59:59.000Z

    This best practices guide for residential HVAC system retrofits is aimed at contractors who want guidance on delivering energy efficient, cost effective and innovative products. It has been developed around the idea of having packages of changes to the building HVAC system and building envelope that are climate and house construction dependent. These packages include materials, procedures and equipment and are designed to remove some of the guesswork from a builder, contractor, installer or homeowner decisions about how best to carry out HVAC changes. The packages are not meant to be taken as rigid requirements--instead they are systems engineered guidelines that form the basis for energy efficient retrofits. Similar approaches have been taken previously for new construction to develop extremely energy efficient homes that are comfortable safe and durable, and often cost less than standard construction. This is best epitomized by the Building America program whose partners have built thousands of residences throughout the U.S. using these principles. The differences between retrofitting and new construction tend to limit the changes one can make to a building, so these packages rely on relatively simple and non-intrusive technologies and techniques. The retrofits also focus on changes to a building that will give many years of service to the occupants. Another key aspect of these best practices is that we need to know how a house is working so that we know what parts have the potential for improvement. To do this we have put together a set of diagnostic tools that combine physical measurements and checklists/questionnaires. The measured test results, observations and homeowner answers to questions are used to direct us towards the best retrofits applicable to each individual house. The retrofits will depend on the current condition of the building envelope and HVAC system, the local climate, the construction methods used for the house, and the presence of various energy saving systems (e.g., a Heat Recovery Ventilator) and/or materials. This is just like a doctor referring a patient for blood tests or x-rays before actually performing surgery. This way the doctor can be sure that he does the right thing. To take this analogy further--we can borrow from the medical profession and say that the first thought when retrofitting a house is to do no harm, i.e., do not make changes that could make the house worse to live in.

  15. Bridging the Gap Between Commissioning Measures and Large Scale Retrofits in Existing Buildings

    E-Print Network [OSTI]

    Bynum, J.; Jones, A.; Claridge, D.E.

    2011-01-01T23:59:59.000Z

    Most often commissioning of existing buildings seeks to reduce a building's energy consumption by implementation of operational changes via the existing equipment. In contrast, large scale capital retrofits seek to make major changes...

  16. Bridging the Gap Between Commissioning Measures and Large Scale Retrofits in Existing Buildings

    E-Print Network [OSTI]

    Bynum, J.; Jones, A.; Claridge, D. E.

    Most often commissioning of existing buildings seeks to reduce a building’s energy consumption by implementation of operational changes via the existing equipment. In contrast, large scale capital retrofits seek to make major changes to the systems...

  17. HOLDSWORTH RETROFIT AND RENOVATION

    E-Print Network [OSTI]

    Schweik, Charles M.

    IPCC report, the buildings sector has more potential to contribute to climate change mitigation thanHOLDSWORTH RETROFIT AND RENOVATION GREEN BUILDING COMMITTEE ENVIRONMENTAL PERFORMANCE ADVISORY Holdsworth Hall Shower and Bicycle Commuting 20 Behavioral Change /Green Office Program 22 ENERGY CONSUMPTION

  18. Multifamily Ventilation Retrofit Strategies

    SciTech Connect (OSTI)

    Ueno, K.; Lstiburek, J.; Bergey, D.

    2012-12-01T23:59:59.000Z

    In multifamily buildings, central ventilation systems often have poor performance, overventilating some portions of the building (causing excess energy use), while simultaneously underventilating other portions (causing diminished indoor air quality). BSC and Innova Services Corporation performed a series of field tests at a mid-rise test building undergoing a major energy audit and retrofit, which included ventilation system upgrades.

  19. Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot-Humid Climate

    SciTech Connect (OSTI)

    Sutherland, K.; Martin, E.

    2013-02-01T23:59:59.000Z

    This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

  20. Evaluation of Retrofit Delivery Packages

    SciTech Connect (OSTI)

    Berman, M.; Smith, P.; Porse, E.

    2013-07-01T23:59:59.000Z

    Residential energy retrofit activities are a critical component of efforts to increase energy efficiency in the U.S. building stock; however, retrofits account for a small percentage of aggregate energy savings at relatively high per unit costs. This report by Building America research team, Alliance for Residential Building Innovation (ARBI), describes barriers to widespread retrofits and evaluates opportunities to improve delivery of home retrofit measures by identifying economies of scale in marketing, energy assessments, and bulk purchasing through pilot programs in portions of Sonoma, Los Angeles, and San Joaquin Counties, CA. These targeted communities show potential and have revealed key strategies for program design, as outlined in the report.

  1. EECBG Success Story: Cincinnati Canvassing Spreads Retrofitting...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cincinnati Canvassing Spreads Retrofitting Message EECBG Success Story: Cincinnati Canvassing Spreads Retrofitting Message May 28, 2010 - 3:07pm Addthis A volunteer canvasses the...

  2. Retrofit Ventilation Strategies in Multifamily Buildings Webinar...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Retrofit Ventilation Strategies in Multifamily Buildings Webinar Retrofit Ventilation Strategies in Multifamily Buildings Webinar Slides from the Building America webinar on...

  3. Building America Expert Meeting: Retrofit Implementation - A...

    Energy Savers [EERE]

    Building America Expert Meeting: Retrofit Implementation - A Neighborhood at a Time Building America Expert Meeting: Retrofit Implementation - A Neighborhood at a Time This report...

  4. Ecology Action: Small Market Advanced Retrofit Transformation...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Ecology Action: Small Market Advanced Retrofit Transformation Program - 2015 Peer Review Ecology Action: Small Market Advanced Retrofit Transformation Program - 2015 Peer Review...

  5. Pilot Residential Deep Energy Retrofits and the PNNL Lab Homes

    SciTech Connect (OSTI)

    Widder, Sarah H.; Chandra, Subrato; Parker, Graham B.; Sande, Susan; Blanchard, Jeremy; Stroer, Dennis; McIlvaine, Janet; Chasar, David; Beal, David; Sutherland, Karen

    2012-01-01T23:59:59.000Z

    This report summarizes research investigating the technical and economic feasibility of several pilot deep energy retrofits, or retrofits that save 30% to 50% or more on a whole-house basis while increasing comfort, durability, combustion safety, and indoor air quality. The work is being conducted for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. As part of the overall program, Pacific Northwest National Laboratory (PNNL) researchers are collecting and analyzing a comprehensive dataset that describes pre- and post-retrofit energy consumption, retrofit measure cost, health and comfort impacts, and other pertinent information for each home participating in the study. The research and data collection protocol includes recruitment of candidate residences, a thorough test-in audit, home energy modeling, and generation of retrofit measure recommendations, implementation of the measures, test-out, and continued evaluation. On some homes, more detailed data will be collected to disaggregate energy-consumption information. This multi-year effort began in October 2010. To date, the PNNL team has performed test-in audits on 51 homes in the marine, cold, and hot-humid climate zones, and completed 3 retrofits in Texas, 10 in Florida, and 2 in the Pacific Northwest. Two of the retrofits are anticipated to save 50% or more in energy bills and the others - savings are in the 30% to 40% range. Fourteen other retrofits are under way in the three climate zones. Metering equipment has been installed in seven of these retrofits - three in Texas, three in Florida, and one in the Pacific Northwest. This report is an interim update, providing information on the research protocol and status of the PNNL deep energy retrofit project as of December, 2011. The report also presents key findings and lessons learned, based on the body of work to date. In addition, the report summarizes the status of the PNNL Lab Homes that are new manufactured homes procured with minimal energy-efficiency specifications typical of existing homes in the region, and sited on the PNNL campus. The Lab Homes serve as a flexible test facility (the first of its kind in the Pacific Northwest) to rapidly evaluate energy-efficient and grid-smart technologies that are applicable to residential construction.

  6. Process Energy Retrofits

    E-Print Network [OSTI]

    Steinmeyer, D.

    shows up in a discharge of added heat to ambient and is spotted more quickly. (Not Replace) I~ - ......... c.... Doml..... By IneremanUl Coata Area Fortunately, there are snort CIrcUits past some of the other activation energy barriers...optimum Is the low point on the curve. The discontinuity or activation energy Is due to the coats.of weatherproofing, etc. Note that for this exlsti" Process Energy Retrofits Dan Steinmeyer Monsanto Co St. Louis, Mo U N C E R E T N...

  7. Measure Guideline: Hybrid Foundation Insulation Retrofits

    SciTech Connect (OSTI)

    Ueno, K.; Lstiburek, J.

    2012-05-01T23:59:59.000Z

    This measure guideline provides recommendations for designs and variations for retrofit hybrid assemblies in improving interior foundation insulation and water management of basements. Variations include closed cell spray foam (ccSPF) with membrane waterproofing or air gap membrane drainage layers, rigid board foam insulation at flat walls (cast concrete or CMU block), a 'partial drainage' detail making use of the bulk water drainage that occurs through the field of a rubble stone wall, and non-drained spray foam assemblies (including slab insulation).

  8. Grupe Homes Enters the Whole-House Retrofit Market

    SciTech Connect (OSTI)

    Hefty, Marye G.; Gilbride, Theresa L.

    2010-03-01T23:59:59.000Z

    This article for HomeEnergy Magazine, a trade magazine on energy efficient home construction, retrofitting, remodeling, and research, describes retrofit projects by Grupe Homes of Sacramento, California, a production builder who has worked with DOE's Building America program on energy-efficient home demonstration projects. In this project, The article is a case study of Grupe's decision to enter the energy efficient remodeling market when new home sales lagged due to the economic slowdown starting in late 2007. The article also describes an energy-efficient retrofit of of a 22-year-old, 3-bedroom home in California’s Central Valley done in 2009 by Grupe. The home is Grupe's first retrofit and was done according to the criteria of Home Performance with ENERGY STAR, a national program from the EPA and DOE that promotes a comprehensive, whole-house approach to making energy-efficiency improvements. Grupe's staff were trained through the California Building Performance Contractors Association and passed the Building Performance Institute test to learn how to conduct extensive energy audits of existing houses as well to perform the energy efficient retrofits. In the retrofit home, they did extensive air sealing, replaced and added insulation, and replaced inefficient HVAC equipment and leaky can lights. They cut air leakage from 2478 to 1115 cfm 50, a 55% reduction. A Building America case study on this project was distributed at the EEBA (Energy and Environmental Building Alliance) Annual Conference in Denver, Colorado, Sept 28-30, 2009. The Home Energy article was published in the March/April 2010 issue.

  9. A Methodology for Identifying Retrofit Energy Savings in Commercial Buildings

    E-Print Network [OSTI]

    Kissock, K.; Reddy, A.; Claridge, D.

    Measured energy savings resulting from energy conservation retrofits in commercial buildings can be used to verify the success of the retrofits, determine the payment schedule for the retrofits, and guide the selection of future retrofits...

  10. A Methodology for Identifying Retrofit Energy Savings in Commercial Buildings 

    E-Print Network [OSTI]

    Kissock, K.; Reddy, A.; Claridge, D.

    1992-01-01T23:59:59.000Z

    Measured energy savings resulting from energy conservation retrofits in commercial buildings can be used to verify the success of the retrofits, determine the payment schedule for the retrofits, and guide the selection of future retrofits...

  11. Guidelines for Retrofit Performance Monitoring

    E-Print Network [OSTI]

    Ternes, M. P.

    1987-01-01T23:59:59.000Z

    the collection of data (more detailed than billing data) that are needed to fully understand retrofit energy performance. The guideline identifies the important data parameters that should be collected to meet this need and defines the data parameters to ensure...

  12. Advancing Residential Retrofits in Atlanta

    SciTech Connect (OSTI)

    Jackson, Roderick K [ORNL; Kim, Eyu-Jin [Southface Energy Institute; Roberts, Sydney [Southface Energy Institute; Stephenson, Robert [Southface Energy Institute

    2012-07-01T23:59:59.000Z

    This report will summarize the home energy improvements performed in the Atlanta, GA area. In total, nine homes were retrofitted with eight of the homes having predicted source energy savings of approximately 30% or greater based on simulated energy consumption.

  13. Amr Shaat, David Schnerch, Amir Fam, and Sami Rizkalla Retrofit of Steel Structures Using Fiber Reinforced Polymers (FRP): State-of-the-Art

    E-Print Network [OSTI]

    on retrofit of steel members including repair of naturally corroded beams, repair of artificially notched and the durability of retrofitted systems, particularly the issue of galvanic corrosion. Available field applications heavy lifting equipment and can add considerably more dead load to the structure, which reduces

  14. Retrofitting analysis of integrated bio-refineries 

    E-Print Network [OSTI]

    Cormier, Benjamin R.

    2007-04-25T23:59:59.000Z

    the economic performance of fossil-based facilities can be enhanced by retrofitting and incorporation of bio-mass feedstocks. These systems can be regarded as bio-refineries or integrated fossilbio- refineries. This work presents a retrofitting analysis...

  15. Charlotte Green Supply Chain: Residential Retrofitting | Department...

    Broader source: Energy.gov (indexed) [DOE]

    Charlotte Green Supply Chain: Residential Retrofitting Charlotte Green Supply Chain: Residential Retrofitting July 30, 2010 - 10:50am Addthis Joshua DeLung What does this mean for...

  16. Strategy Guideline: Mitigation of Retrofit Risk Factors

    SciTech Connect (OSTI)

    Berman, M.; Smith, P.; Porse, E.

    2012-12-01T23:59:59.000Z

    The Alliance for Residential Building Innovation (ARBI) is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

  17. Building America Webinar: Retrofitting Central Space Conditioning...

    Energy Savers [EERE]

    Strategies for Multifamily Buildings - Control strategies to improve hydronic space heating performance Building America Webinar: Retrofitting Central Space Conditioning...

  18. Building America Webinar: Retrofit Ventilation Strategies in...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Strategies in Multifamily Buildings Webinar Building America Webinar: Retrofit Ventilation Strategies in Multifamily Buildings Webinar This webinar, presented by...

  19. Building America Webinar: Retrofitting Central Space Conditioning...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Introduction Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings - Introduction This presentation serves as the introduction to...

  20. Measuring retrofit savings in commercial buildings with pre-retrofit utility billing data and post-retrofit sub-metered data 

    E-Print Network [OSTI]

    Liu, Yue

    1993-01-01T23:59:59.000Z

    Methodologies to measure energy and dollar savings resulting from energy conserving retrofits in commercial buildings when both pre-retrofit and post-retrofit monitored data are available at an hourly or daily level have ...

  1. Retrofit Savings for Brazos County

    E-Print Network [OSTI]

    Baltazar-Cervantes, J. C.; Shao, X.; Claridge, D. E.

    2001-01-01T23:59:59.000Z

    This report presents the energy and dollar savings for the period May 2000 - April 2001 for 10 of the Brazos County facilities that have been retrofit. The electricity use saved was 555,170 kWh and the demand was 1062 kW, which is equivalent to a...

  2. Sunnyvale Marine Climate Deep Retrofit

    SciTech Connect (OSTI)

    German, A.; Siddiqui, A.; Dakin, B.

    2014-11-01T23:59:59.000Z

    The Alliance for Residential Building Innovation (ARBI) and Allen Gilliland of One Sky Homes collaborated on a marine climate retrofit project designed to meet both Passive House (PH) and Building America (BA) program standards. The scope included sealing, installing wall, roof and floor insulation (previously lacking), replacing windows, upgrading the heating and cooling system, and installing.

  3. Advanced Catalytic Hydrogenation Retrofit Reactor

    SciTech Connect (OSTI)

    Reinaldo M. Machado

    2002-08-15T23:59:59.000Z

    Industrial hydrogenation is often performed using a slurry catalyst in large stirred-tank reactors. These systems are inherently problematic in a number of areas, including industrial hygiene, process safety, environmental contamination, waste production, process operability and productivity. This program proposed the development of a practical replacement for the slurry catalysts using a novel fixed-bed monolith catalyst reactor, which could be retrofitted onto an existing stirred-tank reactor and would mitigate many of the minitations and problems associated with slurry catalysts. The full retrofit monolith system, consisting of a recirculation pump, gas/liquid ejector and monolith catalyst, is described as a monolith loop reactor or MLR. The MLR technology can reduce waste and increase raw material efficiency, which reduces the overall energy required to produce specialty and fine chemicals.

  4. Mixed-Mode Ventilation and Building Retrofits

    E-Print Network [OSTI]

    Brager, Gail; Ackerly, Katie

    2010-01-01T23:59:59.000Z

    Page 15 Mixed-Mode Ventilation and Building RetrofitsEngineers. 2000. Mixed-mode ventilation. CIBSE ApplicationsMichael. 2000. Hybrid Ventilation Systems: An Arup Approach

  5. Building America Expert Meeting: Interior Insulation Retrofit...

    Broader source: Energy.gov (indexed) [DOE]

    Building Science Corporation team held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011, at the Westford Regency Hotel in...

  6. Homeowner Best Practices Guide for Residential Retrofits

    E-Print Network [OSTI]

    Walker, Iain S.

    2011-01-01T23:59:59.000Z

    retrofitting your homes heating, cooling and ventilationranch style homes getting insufficient heating or cooling.bridge. Adequately heating all of your home is equally

  7. OTEC- Commercial Lighting Retrofit Rebate Program

    Broader source: Energy.gov [DOE]

    The Oregon Trail Electric Consumers Cooperative (OTEC) offers a commercial lighting retrofit program that provides rebates for commercial businesses that change existing lighting to more energy...

  8. Review of Existing Energy Retrofit Tools

    E-Print Network [OSTI]

    Lee, Sang Hoon

    2014-01-01T23:59:59.000Z

    Evaluator (beta version) COMBAT LBNL / China Energy Groupenergy benchmarking and retrofit recommendations 2.1.8 Evaluator for NYSERDA The Evaluator (currently in beta

  9. Building Energy Model Development for Retrofit Homes

    SciTech Connect (OSTI)

    Chasar, David; McIlvaine, Janet; Blanchard, Jeremy; Widder, Sarah H.; Baechler, Michael C.

    2012-09-30T23:59:59.000Z

    Based on previous research conducted by Pacific Northwest National Laboratory and Florida Solar Energy Center providing technical assistance to implement 22 deep energy retrofits across the nation, 6 homes were selected in Florida and Texas for detailed post-retrofit energy modeling to assess realized energy savings (Chandra et al, 2012). However, assessing realized savings can be difficult for some homes where pre-retrofit occupancy and energy performance are unknown. Initially, savings had been estimated using a HERS Index comparison for these homes. However, this does not account for confounding factors such as occupancy and weather. This research addresses a method to more reliably assess energy savings achieved in deep energy retrofits for which pre-retrofit utility bills or occupancy information in not available. A metered home, Riverdale, was selected as a test case for development of a modeling procedure to account occupancy and weather factors, potentially creating more accurate estimates of energy savings. This “true up” procedure was developed using Energy Gauge USA software and post-retrofit homeowner information and utility bills. The 12 step process adjusts the post-retrofit modeling results to correlate with post-retrofit utility bills and known occupancy information. The “trued” post retrofit model is then used to estimate pre-retrofit energy consumption by changing the building efficiency characteristics to reflect the pre-retrofit condition, but keeping all weather and occupancy-related factors the same. This creates a pre-retrofit model that is more comparable to the post-retrofit energy use profile and can improve energy savings estimates. For this test case, a home for which pre- and post- retrofit utility bills were available was selected for comparison and assessment of the accuracy of the “true up” procedure. Based on the current method, this procedure is quite time intensive. However, streamlined processing spreadsheets or incorporation into existing software tools would improve the efficiency of the process. Retrofit activity appears to be gaining market share, and this would be a potentially valuable capability with relevance to marketing, program management, and retrofit success metrics.

  10. Retrofit for Plastic Resin Driers

    E-Print Network [OSTI]

    Joseph, B.; Thuro, G.

    RETROFIT FOR PLASTIC RESIN DRIERS BABU JOSEPH PH.D. Supervising Engineer Southern California Edison Company, Irwindale, California GEORGE THURO Thuro, & Associates, Costa Mesa, California Plastic resins used in injection molding have... installation of dew point meters and a programmable controller to tailor the regeneration cycle to the required dew point temperature. Background It was estimated that there are about 450 plastic processors in the Southern California Edison service...

  11. Emission Control Systems and Components for Retrofit and First...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Systems and Components for Retrofit and First-Fit Applications Emission Control Systems and Components for Retrofit and First-Fit Applications 2004 Diesel Engine Emissions...

  12. Building America Webinar: Deep Energy Retrofit Case Studies:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Deep Energy Retrofit Case Studies: Lessons Learned Building America Webinar: Deep Energy Retrofit Case Studies: Lessons Learned This presentation by Alea German is included in the...

  13. Better Buildings Financing Energy Efficiency Retrofits in the...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Financing Energy Efficiency Retrofits in the Commercial Sector -- Part 1 Better Buildings Financing Energy Efficiency Retrofits in the Commercial Sector -- Part 1 Slides from the...

  14. Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active Diesel Particulate Filters Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active Diesel Particulate...

  15. EECBG Success Story: Lighting Retrofits Saving Energy, Helping...

    Energy Savers [EERE]

    Retrofits Saving Energy, Helping Local Companies EECBG Success Story: Lighting Retrofits Saving Energy, Helping Local Companies August 9, 2010 - 12:06pm Addthis LEDs such as this...

  16. Syngas Generator Use for Retrofit DPF Active Regeneration on...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Generator Use for Retrofit DPF Active Regeneration on a Medium Duty Truck Syngas Generator Use for Retrofit DPF Active Regeneration on a Medium Duty Truck Syngas enables low...

  17. Building America Expert Meeting Report: Interior Insulation Retrofit...

    Broader source: Energy.gov (indexed) [DOE]

    Interior Insulation Retrofit of Mass Masonry Wall Assembliesessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce...

  18. Strategy Guideline: Energy Retrofits for Low-Rise Multifamily Buildings in Cold Climates

    SciTech Connect (OSTI)

    Frozyna, K.; Badger, L.

    2013-04-01T23:59:59.000Z

    This Strategy Guideline explains the benefits of evaluating and identifying energy efficiency retrofit measures that could be made during renovation and maintenance of multifamily buildings. It focuses on low-rise multifamily structures (three or fewer stories) in a cold climate. These benefits lie primarily in reduced energy use, lower operating and maintenance costs, improved durability of the structure, and increased occupant comfort. This guideline focuses on retrofit measures for roof repair or replacement, exterior wall repair or gut rehab, and eating system maintenance. All buildings are assumed to have a flat ceiling and a trussed roof, wood- or steel-framed exterior walls, and one or more single or staged boilers. Estimated energy savings realized from the retrofits will vary, depending on the size and condition of the building, the extent of efficiency improvements, the efficiency of the heating equipment, the cost and type of fuel, and the climate location.

  19. Irrigation Retrofit Program Improving sprinkler system efficiency

    E-Print Network [OSTI]

    Jawitz, James W.

    Irrigation Retrofit Program Improving sprinkler system efficiency Approximately 70% of the homes of irrigation system retrofits that qualify for rebates Contact the Extension Service. MiamiDade County in MiamiDade County have h i l i i i i d i d i l ( h l f )mechanical irrigation timers and indexing valves

  20. Bay Ridge Gardens - Mixed-Humid Affordable Multifamily Housing Deep Energy Retrofit

    SciTech Connect (OSTI)

    Lyons, J.; Moore, M.; Thompson, M.

    2013-08-01T23:59:59.000Z

    Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a 'base scope' retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a 'DER scope' which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

  1. USER SATISFACTION WITH INNOVATIVE COOLING RETROFITS IN SACRAMENTO PUBLIC HOUSING

    E-Print Network [OSTI]

    Diamond, Richard

    and a housing authority have been retrofitting their buildings with evaporative coolers, ground-source heatpumps

  2. Proven Performance of Seven Cold Climate Deep Retrofit Homes

    SciTech Connect (OSTI)

    Osser, R.; Neuhauser, K.; Ueno, K.

    2012-06-01T23:59:59.000Z

    Seven test homes located in Massachusetts are examined within this report. The retrofit strategies of each home are presented along with a comparison of the pre- and post-retrofit airtightness achieved by the group. Pre- and post-retrofit utility bills were collected; energy models were used to estimate pre-retrofit energy use when bills were unavailable.

  3. Retrofitting CO{sub 2} capture

    SciTech Connect (OSTI)

    Weisel, J.

    2009-07-01T23:59:59.000Z

    Retrofitting existing fossil-fueled plants with the first available carbon dioxide capture technologies could play an important role in paving the way for development of lower-cost, reliable carbon capture and storage systems. EPRI research is helping utilities better understand the engineering challenges and economic consequences. Studies are being conducted on retrofitting five different plants with advanced amine PCC technologies. Other studies include: process optimization studies; valuing operating flexibility; CO{sub 2} capture for CTCC plants; and assessing the impact of climate policy on retrofitting investment.

  4. Retrofitting the Streetlights in Boise, Idaho

    ScienceCinema (OSTI)

    Young, Clay; Oliver, LeAnn; Bieter, David; Johnson, Michael; Oldemeyer, Neal

    2013-05-29T23:59:59.000Z

    Boise, Idaho is using an energy efficiency grant to retrofit hundreds of streetlights throughout the downtown area with energy-efficient LED bulbs, which will save money and improve safety and local quality of life.

  5. Retrofitting the Streetlights in Boise, Idaho

    Broader source: Energy.gov [DOE]

    Boise, Idaho is using an energy efficiency grant to retrofit hundreds of streetlights throughout the downtown area with energy-efficient LED bulbs, which will save money and improve safety and...

  6. Application of Pinch Technology in Refinery Retrofits

    E-Print Network [OSTI]

    Thomas, W. R.; Siegell, J. H.; Sideropoulos, T.; Robertson, J. L.; Papoulias, S. A.

    APPLICATION OF PINCH TECHNOLOGY IN REFINERY RETROFITS W. R. L. Thomas, J. H. Siegell, T. Sideropoulos, J. L. Robertson, S. A. Papoulias Exxon Research and Engineering Company Florham Park, New Jersey ABSTRACT This paper reviews... the application of pinch technology in the identification of the most attractive retrofit prospects in typical refineries. In the first part of the paper, methodology is described to identify attractive inter-unit heat integration opportunities as well...

  7. Making your Building Smarter : The Retrofit Challenge

    E-Print Network [OSTI]

    Brady, N.

    2012-01-01T23:59:59.000Z

    Wireless Temp Sensors IBM Dublin Research Labs : Smart Buildings Living Lab Environment Background ? 2012 IBM Corporation IBM Dublin Research Labs Our Smart Building Retrofit Challenges Retrofit Challenges Summary 1. Smart Building Design 2... Comfortable environment ?Reduce Energy/Water usage environment ?Keep within Budget ?Biggest Challenge ?? Constantly competing (& changing) objectives within the design and build cycles What to include ? What is critical? Where to Invest ? 5 ? 2012...

  8. Evaluation of passive solar retrofit options

    SciTech Connect (OSTI)

    Ben-David, S.; Kirchemen, C.; Martin, S.; Noll, S.; Roach, F.

    1980-01-01T23:59:59.000Z

    An evaluation framework has been developed which allows for the assessment of the role of passive solar retrofit in the nationwide reduction of conventional fuel use. Three types of analysis are proposed within this framework: the physical/technical capability of the present housing stock to incorporate passive solar retrofit; the economic feasibility of the application of retrofit designs; and the actual market potential or acceptance of these alternative retrofit options. Each type of analysis has specific data requirements and a series of evaluation procedures to help establish estimates of the potential for passive solar retrofit in the present housing stock. The data requirements with their respective sources and evaluation procedures for the first two types of analysis-physical/technical setting and economic feasibility, are examined. A distinction is drawn between community specific case studies and more generalized national assessments. Information derived from these three types of analysis, whether case specific or national in scope, can then be used in an evaluation of potential economic impacts. The establishment of regional economic benefits and costs werve as a measure of the merit or attractiveness of the implementation of a passive solar retrofit program.

  9. Boston solar retrofits: studies of solar access and economics

    SciTech Connect (OSTI)

    Shapiro, M.

    1980-11-01T23:59:59.000Z

    Studies of solar access and solar retrofit economics are described for residential applications in the City of Boston. The study of solar access was based upon a random sample of 94 buildings; the sample was stratified to ensure a broad geographic representation from the city's various sections. Using available data on the heights and orientations of the sampled structures and surrounding buildings, each building's hourly access to sunlight was computed separately for the roof and south facing walls. These data were then aggregated by broad structural classifications in order to provide general measures of solar access. The second study was a comparative analysis of the economics of several solar heating and hot water systems. An active hot water system, installed using pre-assembled, commercially purchased equipment, was selected as a reference technology. A variety of measures of economic performance were computed for this system, with and without existing tax credits and under various financing arrangements. Next, a number of alternative approaches for solar space and water heating were identified from interviews with individuals and groups involved in solar retrofit projects in the Boston area. The objective was to identify approaches that many of those interviewed believe to be low-cost means of applying solar energy in residential settings. The approaches selected include thermal window covers, wall collectors, bread box water heaters, and sun spaces. Preliminary estimates of the performance of several representative designs were developed and the economics of these designs evaluated.

  10. Data and Analytics to Inform Energy Retrofit of High Performance Buildings

    SciTech Connect (OSTI)

    Hong , Tianzhen; Yang, Le; Hill, David; Feng , Wei

    2014-01-25T23:59:59.000Z

    Buildings consume more than one-third of the world?s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis ? energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high performance building in California to analyze its energy use and identify retrofit opportunities, including: (1) analyzing patterns of major energy end-use categories at various time scales, (2) benchmarking the whole building total energy use as well as major end-uses against its peers, (3) benchmarking the power usage effectiveness for the data center, which is the largest electricity consumer in this building, and (4) diagnosing HVAC equipment using detailed time-series operating data. Finally, a few energy efficiency measures were identified for retrofit, and their energy savings were estimated to be 20percent of the whole-building electricity consumption. Based on the analyses, the building manager took a few steps to improve the operation of fans, chillers, and data centers, which will lead to actual energy savings. This study demonstrated that there are energy retrofit opportunities for high performance buildings and detailed measured building performance data and analytics can help identify and estimate energy savings and to inform the decision making during the retrofit process. Challenges of data collection and analytics were also discussed to shape best practice of retrofitting high performance buildings.

  11. Post-Retrofit Residential Assessments

    SciTech Connect (OSTI)

    Lancaster, Ross; lutzenhiser, Loren; Moezzi, Mithra; Widder, Sarah H.; Chandra, Subrato; Baechler, Michael C.

    2012-04-30T23:59:59.000Z

    This study examined a range of factors influencing energy consumption in households that had participated in residential energy-efficiency upgrades. The study was funded by a grant from the U.S. Department of Energy’s Pacific Northwest National Laboratory and was conducted by faculty and staff of Portland State University Center for Urban Studies and Department of Economics. This work was made possible through the assistance and support of the Energy Trust of Oregon (ETO), whose residential energy-efficiency programs provided the population from which the sample cases were drawn. All households in the study had participated in the ETO Home Performance with Energy Star (HPwES) program. A number of these had concurrently pursued measures through other ETO programs. Post-retrofit energy outcomes are rarely investigated on a house-by-house basis. Rather, aggregate changes are ordinarily the focus of program impact evaluations, with deviation from aggregate expectations chalked up to measurement error, the vagaries of weather and idiosyncrasies of occupants. However, understanding how homes perform post-retrofit on an individual basis can give important insights to increase energy savings at the participant and the programmatic level. Taking a more disaggregated approach, this study analyzed energy consumption data from before and after the retrofit activity and made comparisons with engineering estimates for the upgrades, to identify households that performed differently from what may have been expected based on the estimates. A statistical analysis using hierarchal linear models, which accounted for weather variations, was performed looking separately at gas and electrical use during the periods before and after upgrades took place. A more straightforward comparison of billing data for 12-month periods before and after the intervention was also performed, yielding the majority of the cases examined. The later approach allowed total energy use and costs to be assessed but did not account for weather variation. From this statistical analysis, 18 study participants were selected and interviewed. The participants completed an in-home interview covering a range of topics, including changes in occupancy and additional changes to the homes that may have affected energy use. The goal of the interviews was to identify factors that may have contributed to unusual energy performance. These factors were identified by their frequency of occurrence in outperforming or underperforming homes, or simply by identifying factors that had the largest impact on overall savings. The motivations and levels of satisfaction with the outcomes of the upgrades were covered in detail, as well as extensive discussions of behaviors pertaining to thermal control, lighting, water, and appliance use. Most of cases studied achieved substantial energy savings, although it was more common for the projected savings to be greater than the demonstrated savings. Two factors that played a very large role in savings variation were 1) changes in occupancy and 2) fenestration improvements outside of the incentive programs. Motivation for pursuing the upgrades (e.g., environmental sustainability vs. comfort or cost savings) did not seem to play any role in achieving savings. Participants generally were more concerned with maintaining aesthetics through lighting than comfort through heating or cooling. They also seemed more likely to turn the lights off when leaving a room than to turn the heat off when leaving the home.

  12. Indoor Environmental Quality Benefits of Apartment Energy Retrofits

    E-Print Network [OSTI]

    Urban Habitat Initiatives Inc. Boston, MA, USA June 2013 Funding was provided by the California Energy energy consumption and improving indoor environmental quality (IEQ). Retrofit measures varied among1 Indoor Environmental Quality Benefits of Apartment Energy Retrofits Federico Norisa, , Gary

  13. Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

    SciTech Connect (OSTI)

    Wang, Weimin; Katipamula, Srinivas; Ngo, Hung; Underhill, Ronald M.; Taasevigen, Danny J.; Lutes, Robert G.

    2013-07-31T23:59:59.000Z

    The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

  14. NREL Job Task Analysis: Retrofit Installer Technician (Revised)

    SciTech Connect (OSTI)

    Kurnik, C.; Woodley, C.

    2012-04-01T23:59:59.000Z

    A summary of job task analyses for the position of retrofit installer technician when conducting weatherization work on a residence.

  15. Ready to Retrofit: The Process of Project Team Selection, Building Benchmarking, and Financing Commercial Building Energy Retrofit Projects

    E-Print Network [OSTI]

    Sanders, Mark D.

    2014-01-01T23:59:59.000Z

    potential  oversight  of  retrofit  and  construction  projects   •   familiarity  with  ASHRAE  energy  efficiency  and  ventilation  requirements   •   familiarity  with  renewable  

  16. Low NO sub x /SO sub x Burner retrofit for utility cyclone boilers

    SciTech Connect (OSTI)

    Not Available

    1990-01-01T23:59:59.000Z

    The objective of this project is to demonstrate the LNS Burner as retrofitted to the host cyclone boiler for effective low-cost control of NO{sub x} and SO{sub x} emissions while firing a bituminous coal. The LNS Burner employs a simple, innovative combustion process to burn pulverized coal at high temperatures and provides effective, low-cost control of sulfur dioxide (SO{sub 2}) and nitrogen oxides (NO{sub x}) emissions. The coal ash contains sulfur and is removed in the form of molten slag and flyash. Cyclone-fired boiler units are typically older units firing high-sulfur bituminous coals at very high temperatures which results in very high NO{sub x} and SO{sub x} emissions. The addition of conventional emission control equipment, such as wet scrubbers, to these older cyclone units in order to meet current and future environmental regulations is generally not economic. Further, the units are generally not compatible with low sulfur coal switching for S0{sub 2} control or selective catalytic reduction technologies for NO{sub x} control. Because the LNS Burner operates at the same very high temperatures as a typical cyclone boiler and produces a similar slag product, it may offer a viable retrofit option for cyclone boiler emission control. This was confirmed by the Cyclone Boiler Retrofit Feasibility Study carried out by TransAlta and an Operating Committee formed of cyclone boiler owners in 1989. An existing utility cyclone boiler, was then selected for the evaluation of the cost and performance study. It was concluded that the LNS Burner retrofit would be a cost-effective option for control of cyclone boiler emissions. A full-scale demonstration of the LNS Burner retrofit was selected in October 1988 as part of the DOE's Clean Coal Technology Program Round II.

  17. Advanced Energy Retrofit Guide Retail Buildings

    SciTech Connect (OSTI)

    Liu, Guopeng; Liu, Bing; Zhang, Jian; Wang, Weimin; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

    2011-09-19T23:59:59.000Z

    The Advanced Energy Retrofit Guide for Retail Buildings is a component of the Department of Energy’s Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

  18. Advanced Energy Retrofit Guide Office Buildings

    SciTech Connect (OSTI)

    Liu, Guopeng; Liu, Bing; Wang, Weimin; Zhang, Jian; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

    2011-09-27T23:59:59.000Z

    The Advanced Energy Retrofit Guide for Office Buildings is a component of the Department of Energy’s Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

  19. Experience with 113 Retrofit Insulation Surveys

    E-Print Network [OSTI]

    Webber, W. O.

    EXPERIENCE WITH 113 RETROFIT INSULATION SURVEYS W. O. Webber Energy Conservation Consultants Baytown, Texas ABSTRACT We have surveyed 113 plants for thirteen clie~ts. The results of 21 recent surveys, at today s avera&e fuel price, show...,000 for $3.00 fuel up to $80,000 for $6.00 fuel. When this happens, the project return will increase from 100% up to 165% per year. The main problem that we have found with retrofit insulation surveys is the processing of detail in existing plants...

  20. Retrofitting sacrificial anodes in the Arabian Gulf

    SciTech Connect (OSTI)

    Kiefer, J.H.; Thomason, W.H.; Alansari, N.G.

    1999-08-01T23:59:59.000Z

    Cathodic protection (CP) systems of 15 fixed offshore platforms were analyzed. These steel template structures, off the coast of the United Arab Emirates, are in water depths between 125 and 185 ft (115 and 170 m). A systematic survey program exists to monitor the CP systems including assessment of sacrificial anode depletion, and measurement of anode and platform potentials. These data are used to design new anode retrofits for older structures to extend CP system life. An analysis of field survey measurements, the method used to evaluate new anode needs, and locations for retrofit anodes are described.

  1. ARRA Proposed Award: Retrofit Bay Area

    E-Print Network [OSTI]

    ARRA Proposed Award: Retrofit Bay Area Counties of Alameda, Contra Costa, Marin, San Francisco per year Prime contractor: Association of Bay Area Governments (ABAG) Sub contractors: Alameda County Waste Management Authority (StopWaste.org) County of Contra Costa County of Marin City

  2. Evaluation of Crawlspace Retrofits in Multifamily Buildings

    SciTech Connect (OSTI)

    Rudd, A.

    2014-09-01T23:59:59.000Z

    In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community unvented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring. The existing condition was a vented crawlspace with an uninsulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this unvented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods. While the unvented crawlspace retrofit was effective in reducing heat loss, and the majority of the bulk water drainage problems had been resolved, the important finding was that some of the wood joists embedded in masonry pockets behind the brick veneer were showing signs of moisture damage.

  3. Deep Energy Retrofits - Eleven California Case Studies

    E-Print Network [OSTI]

    Less, Brennan

    2014-01-01T23:59:59.000Z

    heat pump water heater is the obvious finishing touch for this retrofit; a PVheat pump and has fairly high plug and lighting loads. Both homes have solar PVheat pump across seasons, as well as the large miscellaneous uses in the home. The PV

  4. National Grid Deep Energy Retrofit Pilot

    SciTech Connect (OSTI)

    Neuhauser, K.

    2012-03-01T23:59:59.000Z

    Through discussion of five case studies (test homes), this project evaluates strategies to elevate the performance of existing homes to a level commensurate with best-in-class implementation of high-performance new construction homes. The test homes featured in this research activity participated in Deep Energy Retrofit (DER) Pilot Program sponsored by the electric and gas utility National Grid in Massachusetts and Rhode Island. Building enclosure retrofit strategies are evaluated for impact on durability and indoor air quality in addition to energy performance. Evaluation of strategies is structured around the critical control functions of water, airflow, vapor flow, and thermal control. The aim of the research project is to develop guidance that could serve as a foundation for wider adoption of high performance, 'deep' retrofit work. The project will identify risk factors endemic to advanced retrofit in the context of the general building type, configuration and vintage encountered in the National Grid DER Pilot. Results for the test homes are based on observation and performance testing of recently completed projects. Additional observation would be needed to fully gauge long-term energy performance, durability, and occupant comfort.

  5. "We retrofitted mechanical systems in 8 buildings!"

    E-Print Network [OSTI]

    "We retrofitted mechanical systems in 8 buildings!" LOW INTEREST RATE LOANS AVAILABLE NOW! County of Contra Costa California Energy Commission Apply Today! See Case Study on Back of Flyer "Our low interest and cooling systems in eight buildings. The energy efficient measures include replacing pneumatic controls

  6. Retrofiting survivability of military vehicles

    SciTech Connect (OSTI)

    Canavan, Gregory H [Los Alamos National Laboratory

    2009-01-01T23:59:59.000Z

    In Iraq the terrain was such that vehicles could be distributed horizontally, which reduced the effectiveness of mines. In the mountainous terrain of Pakistan and Afghanistan vehicles are forced to use the few, passable roads, which are dirt and easily seeded with plentiful, cheap, intelligent mines. It is desirable to reduce the losses to such mines, preferably by retrofit means that do not greatly increase weight or cost or reduce maneuverability. V-bottom vehicles - A known approach to reducing vulnerability is the Buffalo, a large vehicle developed by South Africa to address mine warfare. It has large tires, high axles, and a reinforced, v-shaped bottom that deflects the blast from explosions below. It is developed and tested in combat, but is expensive and has reduced off-road mobility. The domestic MRAP has similar cost and mobility issue. The addition of v-shaped blast deflectors to vehicles such as Humvees could act much as the deflector on a Buffalo, but a Humvee is closer to the ground, so the explosive's expansion would be reduced. The deflector would also reduce a Humvee's clearance for rough terrain, and a deflector of adequate thickness to address the blast by itself could further increase cost and reduce mobility. Reactive armor is developed and has proven effective against shaped and explosive charges from side or top attack. It detects their approach, detonates, and defeats them by interfering with jet formation. If the threat was a shaped charge from below, they would be a logical choice. But the bulk of the damage to Humvees appears to be from the blast from high explosive mines for which the colliding shock from reactive armor could increase that from the explosive. Porous materials such as sand can strongly attenuate the kinetic energy and pressure of a strong shock. Figure 1 shows the kinetic energy (KE), momentum (Mu), velocity (u), and mass (M) of a spherically expanding shock as functions of radius for a material with a porosity of 0.5. Over the range from 0.5 to 4.5 cm the shock KE is attenuated by a factor of {approx}70, while its momentum is changed little. The shock and particle velocity falls by a factor of 200 while the mass increases by a factor of 730. In the limit of very porous media u {approx} 1/M, so KE {approx} 1/M, which falls by a factor of {approx}600, while momentum Mu does not change at all. Figure 2 shows the KE, Mu, u, and M for a material with a porosity of 1.05, for which the KE changes little. In the limit of media of very low porosity, u {approx} 1/{radical}M, so KE is constant while Mu {approx} {radical}M, which increases by a factor of 15. Thus, if the goal is to reduce the peak pressure from strong explosions below, very porous materials, which strongly reduce pressure but do not increase momentum, are preferred to non-porous materials, which amplify momentum but do not decrease pressure. These predictions are in qualitative accord with the results of experiments at Los Alamos in which projectiles from high velocity, large caliber cannons were stopped by one to two sandbags. The studies were performed primarily to determine the effectiveness of sand in stopping fragments of various sizes, but could be extended to study sand's effectiveness in attenuating blast pressure. It would also be useful to test the above predictions on the effectiveness of media with higher porosity. Water barriers have been discussed but not deployed in previous retrofit survivability studies for overseas embassies. They would detect the flash from the mine detonation below, trigger a thin layer of explosive above a layer of water, and drive water droplets into the approaching blast wave. The blast loses energy in evaporating the droplets and loses momentum in slowing them. Under favorable conditions that could attenuate the pressure in the blast enough to prevent the penetration or disruption of the vehicle. However, such barriers would depend on prompt and reliable detonation detection and water droplet dispersal, which have not been tested. There is a large literature on the theoretical effec

  7. Cascade Apartments: Deep Energy Multifamily Retrofit

    SciTech Connect (OSTI)

    Gordon, A.; Mattheis, L.; Kunkle, R.; Howard, L.; Lubliner, M.

    2014-02-01T23:59:59.000Z

    In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions : 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofit package after considering utility window incentives and KCHA capitol improvement funding.

  8. Retrofit California Overview and Final Reports

    SciTech Connect (OSTI)

    Choy, Howard; Rosales, Ana

    2014-03-01T23:59:59.000Z

    Energy efficiency retrofits (also called upgrades) are widely recognized as a critical component to achieving energy savings in the building sector to help lower greenhouse gas (GHG) emissions. To date, however, upgrades have accounted for only a small percentage of aggregate energy savings in building stock, both in California and nationally. Although the measures and technologies to retrofit a building to become energy efficient are readily deployed, establishing this model as a standard practice remains elusive. Retrofit California sought to develop and test new program models to increase participation in the energy upgrade market in California. The Program encompassed 24 pilot projects, conducted between 2010 and mid-2013 and funded through a $30 million American Recovery and Reinvestment Act (ARRA) grant from the U.S. Department of Energy’s (DOE) Better Buildings Neighborhood Program (BBNP). The broad scope of the Program can be seen in the involvement of the following regionally based Grant Partners: Los Angeles County (as prime grantee); Association of Bay Area Governments (ABAG), consisting of: o StopWaste.org for Alameda County o Regional Climate Protection Authority (RCPA) for Sonoma County o SF Environment for the City and County of San Francisco o City of San Jose; California Center for Sustainable Energy (CCSE) for the San Diego region; Sacramento Municipal Utilities District (SMUD). Within these jurisdictions, nine different types of pilots were tested with the common goal of identifying, informing, and educating the people most likely to undertake energy upgrades (both homeowners and contractors), and to provide them with incentives and resources to facilitate the process. Despite its limited duration, Retrofit California undoubtedly succeeded in increasing awareness and education among home and property owners, as well as contractors, realtors, and community leaders. However, program results indicate that a longer timeframe will be needed to transform the market and establish energy retrofits as the new paradigm. Innovations such as Flex Path, which came about because of barriers encountered during the Program, have already shown promise and are enabling increased participation. Together, the pilots represent an unprecedented effort to identify and address market barriers to energy efficiency upgrades and to provide lessons learned to shape future program planning and implementation. The statistics reflects the scope of the marketing and outreach campaigns, which tested a variety of approaches to increase understanding of the benefits of energy upgrades to drive participation in the Program. More traditional methods such as TV and radio advertisements were complimented by innovative community based social marketing campaigns that sought to leverage the trusted status of neighborhood organizations and leaders in order to motivate their constituents to undertake retrofits. The remainder of this report provides an overview of Retrofit California including brief summaries of the pilots’ main components and highlights, followed by the major findings or takeaway lessons from the approaches that were tested. Eleven of the pilots will be continued, with modifications, under the ratepayer-funded Regional Energy Networks. Involvement in the RENS by many of the Retrofit California partners will ensure that early lessons learned are carried forward to guide future programs for energy upgrades in California.

  9. Building America Best Practices Series, Vol. 10 - Retrofit Techniques...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    air leaks in homes, while ensuring healthy levels of ventilation and avoiding indoor air pollution. Retrofit Techniques & Technologies: Air Sealing More Documents &...

  10. Cedarville School District Retrofit of Heating and Cooling Systems...

    Open Energy Info (EERE)

    Jump to: navigation, search Last modified on July 22, 2011. Project Title Cedarville School District Retrofit of Heating and Cooling Systems with Geothermal Heat Pumps and Ground...

  11. Energy - School retrofit paying dividends ... | ornl.gov

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Energy - School retrofit paying dividends ... A ground source heat pump installed at rural Cedarville High School in Arkansas through the American Recovery and Reinvestment Act has...

  12. Retrofit Diesel Emissions Control System Providing 50% NOxControl...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Diesel Emissions Control System Providing 50% NOxControl Retrofit Diesel Emissions Control System Providing 50% NOxControl 2005 Diesel Engine Emissions Reduction (DEER) Conference...

  13. Comparison of Home Retrofit Programs in Wisconsin

    SciTech Connect (OSTI)

    Cunningham, K.; Hannigan, E.

    2013-03-01T23:59:59.000Z

    To explore ways to reduce customer barriers and increase home retrofit completions, several different existing home retrofit models have been implemented in the state of Wisconsin. This study compared these programs' performance in terms of savings per home and program cost per home to assess the relative cost-effectiveness of each program design. However, given the many variations in these different programs, it is difficult to establish a fair comparison based on only a small number of metrics. Therefore, the overall purpose of the study is to document these programs' performance in a case study approach to look at general patterns of these metrics and other variables within the context of each program. This information can be used by energy efficiency program administrators and implementers to inform home retrofit program design. Six different program designs offered in Wisconsin for single-family energy efficiency improvements were included in the study. For each program, the research team provided information about the programs' approach and goals, characteristics, achievements and performance. The program models were then compared with performance results -- program cost and energy savings -- to help understand the overall strengths and weaknesses or challenges of each model.

  14. Retrofit for a college campus

    SciTech Connect (OSTI)

    Cox, R.L. [Avanti Consulting Engineering, St. Louis, MO (United States)

    1996-11-01T23:59:59.000Z

    The Florissant Valley Campus of the St. Louis, MO Community College was constructed during the late 1960s and early 1970s. The main campus consists of 11 classroom, laboratory, and instructional buildings comprising 411,000 ft{sup 2} (38 183 m{sup 2}). The Florissant Valley campus wanted to provide the maintenance staff with a state-of-the-art DDC building automation system which would eliminate manual control of HVAC systems and reduce maintenance. Several of the classrooms and laboratories have had changes in their occupancy and use from the original design intent, and, the campus has consistently been adding additional internal load to many of the spaces in the form of new computers, printers, and other electronic equipment. The original campus HVAC systems were not designed to meet the indoor air quality (IAQ) standards of today. The college specifically requested that the design team prepare the project within DOE guidelines so that ICP grant funds could be used. The college also wanted to have the design team prepare the project in a manner to be bid by Energy Savings Contractors (ESCO) using a Guaranteed Energy Service Contract to assure the college could pay back their investment in the time stated.

  15. Public Housing: A Tailored Approach to Energy Retrofits

    SciTech Connect (OSTI)

    Dentz, J.; Conlin, F.; Podorson, D.; Alaigh, K.

    2014-06-01T23:59:59.000Z

    Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 PHAs across the country indicated that there is a high level of interest in developing low cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations at the time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation in ten housing units. Reductions in average air leakage were 16-20% and duct leakage reductions averaged 38%. Total source energy consumption savings was estimated at 6-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of unit per year nationally.

  16. Ready to Retrofit: The Process of Project Team Selection, Building

    E-Print Network [OSTI]

    , and Financing Commercial Building Energy Retrofit Projects Mark D. Sanders, Kristen Parrish, Paul Mathew for the Commercial Buildings Partnership (CBP) program, sponsored by the U.S. Department of Energy's Building a process for three key activities for the building owner in preparing to retrofit existing commercial

  17. A systems approach to retrofitting residential HVAC systems

    SciTech Connect (OSTI)

    McWilliams, J.A.; Walker, I.S.

    2004-05-01T23:59:59.000Z

    A Best Practices Guide for retrofitting residential HVAC systems has recently been completed by DOE. The guide uses diagnostics and checklists to guide the user to specific retrofit packages that maximize retrofit energy savings, comfort and safety potential. The guide uses a systems approach to retrofitting where the interaction of different building components is considered throughout the retrofit selection process. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC systems can be used. In this study, several houses were surveyed using the Best Practices Guide and a single house was selected for retrofitting. The objectives were to demonstrate how a successful system-wide retrofit can be carried out and to provide feedback to improve the guide. Because it represents a departure from current practice, a key aspect of this study was to investigate the interactions with contractors and code officials who are unfamiliar with the systems approach. The study found that the major barrier to the systems approach in retrofits was in changing the working practices of contractors and code officials.

  18. Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit: Annapolis, Maryland. Building America Case Study: Whole-House Solutions for Existing Homes (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-10-01T23:59:59.000Z

    Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a "base scope" retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a "DER scope" which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

  19. Designing Effective Incentives to Drive Residential Retrofit Program Participation (Text Version)

    Broader source: Energy.gov [DOE]

    Transcript of the webinar, "Designing Effective Incentives to Drive Residential Retrofit Program Participation."

  20. Cathodic protection retrofit of an offshore pipeline

    SciTech Connect (OSTI)

    Winters, R.H.; Holk, A.C. [Tenneco Energy, Houston, TX (United States)

    1997-09-01T23:59:59.000Z

    The cathodic protection anodes and corrosion coating on two 8-inch (203.2 mm) outside diameter (O.D.) offshore pipelines were damaged during deep water ({minus}380 feet, {minus}116 m) installation. In-situ methods for deep water inspection and repair of the pipelines` cathodic protection and coating systems were developed and performed. Methods are described in which underwater anode retrofits were performed and friction welding technology was used to re-attach anode leads. Standard procedures for underwater pipeline coating repair and remediation of damaged line pipe are provided.

  1. Retrofit Ventilation Strategies in Multifamily Buildings Webinar |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingof EnhancedRestructuringNinthRetrofitDepartment of

  2. Air Distribution Retrofit Strategies for Affordable Housing

    SciTech Connect (OSTI)

    Dentz, J.; Conlin, F.; Holloway, P.; Podorson, D.; Varshney, K.

    2014-03-01T23:59:59.000Z

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

  3. An Overview of the Building Energy Retrofit Research Program 

    E-Print Network [OSTI]

    Mixon, W. R.

    1987-01-01T23:59:59.000Z

    fmhr *nr ID pdmn rn r.pc&a dm-(Irmab*rm-,ar .)ar~I~0'S,larU.S Oornmm -- AN OVERVIEW OF THE BUILDING ENERGY RETROFIT RESEARCH PROGRAM WILLIAM R. MIX ON^ Manager Building Energy Retrofit Research Program Oak Ridge National Laboratory Oak Ridge... of achieving energy efficiency. REFERENCES 1. Oak Ridge Natlonal Laboratery, Single-Faally build in^ Retrofit Research Multi-Year Plan, FY 1986-W 1991, ORNL/CON-207, May 1986. 2. Diamond, R. C., C. A. Goldman, H. P. Modera, M. Rothkopf, M. H. Sherman...

  4. DOE Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings

    Broader source: Energy.gov [DOE]

    The Building America Program is hosting a no-cost, webinar-based training on Retrofitting Central Space Conditioning Strategies for Multifamily Buildings. The webinar will focus on improving the...

  5. A Methodology to Measure Retrofit Energy Savings in Commercial Buildings 

    E-Print Network [OSTI]

    Kissock, John Kelly

    2008-01-16T23:59:59.000Z

    . This dissertation develops a methodology to measure retrofit energy savings and the uncertainty of the savings in commercial buildings. The functional forms of empirical models of cooling and heating energy use in commercial buildings are derived from an engineering...

  6. Retrofitting Existing Buildings for Demand Response & Energy Efficiency

    E-Print Network [OSTI]

    California at Los Angeles, University of

    Retrofitting Existing Buildings for Demand Response & Energy Efficiency www rate periods to avoid high charges. · Assembly Bill 1103 ­ Building Energy Efficiency Disclosure - Starting January 1, 2010, all commercial building lease transactions must disclose the energy efficiency

  7. Applications of sustainable technology to retrofits in urban areas

    E-Print Network [OSTI]

    Taylor, Paki (Paki A.), 1974-

    2001-01-01T23:59:59.000Z

    Energy Losses from old buildings comprise a significant percentage of the total residential energy consumption in the United States. Retrofitting buildings for conservation can greatly decrease the present energy demand ...

  8. IRS Parking Facility Lighting Retrofit Reduces Annual Energy...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    in Kansas City, Missouri. The retrofit resulted in annual energy savings of 2 million kWh, annual cost savings of over 122,000, and a simple payback of 2.5 years....

  9. Street and Parking Facility Lighting Retrofit Financial Analysis Tool Webinar

    Broader source: Energy.gov [DOE]

    DOE will present a live webinar titled "Using the Street and Parking Facility Lighting Retrofit Financial Analysis Tool" on Thursday, August 22, from 1:00 p.m. to 2:00 p.m. Eastern Daylight Time....

  10. Retrofit Financial Analysis Tool, Version 1.1.01

    Broader source: Energy.gov [DOE]

    Download a zip file containing the Retrofit Financial Analysis Tool, Version 1.1.01, and an example version of the Tool filled in with sample data. Save the file to your computer before opening..

  11. Retrofit of Existing Residential Building: a Case Study

    E-Print Network [OSTI]

    Zhao, L.; Xu, W.; Li, L.; Gao, G.

    2006-01-01T23:59:59.000Z

    retrofit of the envelope of existing residential buildings should be placed on the wall in northern region. It is possible to reduce about 50 percent of energy consumption of buildings by insulating the wall. The external insulation is suitable...

  12. Puget Sound Energy- Commercial Retrofit Energy Efficiency Grant Program

    Broader source: Energy.gov [DOE]

    PSE can provide a custom retrofit grant for any energy-efficiency project that meets specified cost-effectiveness criteria and other PSE program requirements. To be eligible, customers must...

  13. DOE Webinar - Residential Geothermal Heat Pump Retrofits (Presentation)

    SciTech Connect (OSTI)

    Anderson, E. R.

    2010-12-14T23:59:59.000Z

    This presentation was given December 14, 2010, as part of DOE's Webinar series. The presentation discusses geothermal heat pump retrofits, technology options, and an overview of geothermal energy and geothermal heat pumps.

  14. The retrofitting of existing buildings for seismic criteria

    E-Print Network [OSTI]

    Besing, Christa, 1978-

    2004-01-01T23:59:59.000Z

    This thesis describes the process for retrofitting a building for seismic criteria. It explains the need for a new, performance-based design code to provide a range of acceptable building behavior. It then outlines the ...

  15. Concrete Masonry Wall Retrofit Systems for Blast Protection

    E-Print Network [OSTI]

    Johnson, Carol Faye

    2013-12-11T23:59:59.000Z

    unit (CMU) infill walls, commonly used in reinforced concrete or steel framed structures, are particularly vulnerable to blast loads. Facilities that incorporate CMU walls must either be hardened or retrofitted for explosive events. Conventional...

  16. Retrofit Diesel Emissions Control System Providing 50% NOxControl

    Broader source: Energy.gov (indexed) [DOE]

    Retrofit Diesel Emissions Control System Providing 50% NOx Control D. Yee, B. Adair, A. Boleda, B. Berry, T. Caron, J. Cizeron, T. Kinney, K. Lundberg and R. Dalla Betta Catalytica...

  17. City of Los Angeles- Green Building Retrofit Requirement

    Broader source: Energy.gov [DOE]

    In April 2009, Los Angeles enacted [clkrep.lacity.org/onlinedocs/2006/06-1963_ord_180633.pdf Ordinance 180636], known as the Green Building Retrofit Ordinance. This ordinance was later amended by...

  18. Irrigation Retrofit Program Steps to Improving sprinkler system efficiency

    E-Print Network [OSTI]

    Jawitz, James W.

    Irrigation Retrofit Program Steps to Improving sprinkler system efficiency Step 1. Replace Program provides rebates for improving urban landscape irrigation systems. Homeowners Associations can receive up to $400 for upgrading their irrigation system. In order to receive reimbursement , sign up

  19. Retrofitting the Southeast: The Cool Energy House

    SciTech Connect (OSTI)

    Zoeller, W.; Shapiro, C.; Vijayakumar, G.; Puttagunta, S.

    2013-02-01T23:59:59.000Z

    The Consortium for Advanced Residential Buildings has provided the technical engineering and building science support for a highly visible demonstration home in connection with the National Association of Home Builders' International Builders Show. The two previous projects, the Las Vegas net-zero ReVISION House and the 2011 VISION and ReVISION Houses in Orlando, met goals for energy efficiency, cost effectiveness, and information dissemination through multiple web-based venues. This project, which was unveiled at the 2012 International Builders Show in Orlando on February 9, is the deep energy retrofit Cool Energy House (CEH). The CEH began as a mid-1990s two-story traditional specification house of about 4,000 ft2 in the upscale Orlando suburb of Windermere.

  20. Retrofit of a Multifamily Mass Masonry Building in New England

    SciTech Connect (OSTI)

    Ueno, K.; Kerrigan, P.; Wytrykowska, H.; Van Straaten, R.

    2013-08-01T23:59:59.000Z

    Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

  1. Wyandotte Neighborhood Stabilization Program: Retrofit of Two Homes

    SciTech Connect (OSTI)

    Lukachko, A.; Grin, A.; Bergey, D.

    2013-04-01T23:59:59.000Z

    The Wyandotte NSP2 project aims to build 20 new houses and retrofit 20 existing houses in Wyandotte, MI. This report will detail the retrofit of 2 existing houses in the program. Wyandotte is part of a Michigan State Housing Development Authority-led consortium that is funded by HUD under the NSP2 program. The City of Wyandotte has also been awarded DOE EE&CBG funds that are being used to develop a district GSHP system to service the project. This draft report examines the energy efficiency recommendations for retrofit construction at these homes. The report will be of interest to anyone planning an affordable, high performance retrofit of an existing home in a Cold Climate zone. Information from this report will also be useful to retrofit or weatherization program staff as some of the proposed retrofit solutions will apply to a wide range of projects. Preliminary results from the first complete house suggest that the technology package employed (which includes spray foam insulation and insulating sheathing) does meet the specific whole house water, air, and thermal control requirements, as well as, the project's affordability goals. Monitoring of the GSHP system has been recommended and analysis of this information is not yet available.

  2. Research on Commercial Patterns of China Existing Building Energy Retrofit Based on Energy Management Contract 

    E-Print Network [OSTI]

    Han, Z.; Liu, C.; Sun, J.

    2006-01-01T23:59:59.000Z

    Existing building energy retrofit is one of the keys of building energy efficiency in China. According to experience in developed countries, implementation of energy management contract (EMC) is crucial to promote existing building energy retrofit...

  3. ADEC II Universal SCR Retrofit System for On-road and Off-road...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ADEC II Universal SCR Retrofit System for On-road and Off-road Diesel Engines ADEC II Universal SCR Retrofit System for On-road and Off-road Diesel Engines Presentation given at...

  4. Research on Commercial Patterns of China Existing Building Energy Retrofit Based on Energy Management Contract

    E-Print Network [OSTI]

    Han, Z.; Liu, C.; Sun, J.

    2006-01-01T23:59:59.000Z

    Existing building energy retrofit is one of the keys of building energy efficiency in China. According to experience in developed countries, implementation of energy management contract (EMC) is crucial to promote existing building energy retrofit...

  5. A Bin Method for Calculating Energy Conservation Retrofit Savings in Commercial Buildings

    E-Print Network [OSTI]

    Thamilseran, S.; Haberl, J. S.

    1994-01-01T23:59:59.000Z

    The calculation of measured energy savings from energy conservation retrofits is an important step in the verification of the success of a retrofit (Claridge et al. 1992). Several methods for calculating the savings from energy conservation...

  6. Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst...

    Broader source: Energy.gov (indexed) [DOE]

    Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst on a Tier 0, SD60M Freight Locomotive Achieving Over 50% PM Reduction Retrofit and Testing of a Pre-Turbo, Diesel...

  7. A Bin Method for Calculating Energy Conservation Retrofit Savings in Commercial Buildings 

    E-Print Network [OSTI]

    Thamilseran, S.; Haberl, J. S.

    1994-01-01T23:59:59.000Z

    The calculation of measured energy savings from energy conservation retrofits is an important step in the verification of the success of a retrofit (Claridge et al. 1992). Several methods for calculating the savings from energy conservation...

  8. Case study field evaluation of a systems approach to retrofitting a residential HVAC system

    E-Print Network [OSTI]

    Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

    2003-01-01T23:59:59.000Z

    cfm Retrofit Seal ducts: aeroseal/tape/mastic Add insulationmanual J Seal ducts: Aeroseal/tape/mastic Add insulation tocfm Retrofit Seal ducts: aeroseal/tape/mastic Add insulation

  9. Housing Stock Characterization Study: An Innovative Approach to Measuring Retrofit Impact

    SciTech Connect (OSTI)

    Jones, P.; Taylor, N.; Kipp, J.

    2012-09-01T23:59:59.000Z

    A residential energy efficiency retrofit loan program depends on a self-sustaining finance option and optimized retrofit measures that recoup their unsubsidized costs through energy bill savings alone within the useful life of the retrofit. A first step in evaluating retrofit options is to measure and verify their energy savings. This report evaluates Orlando Utilities Commission (OUC) residential energy-efficiency demand side management (DSM) programs to assess their relative energy and economic performance.

  10. Sustainable Energy Resources for Consumers Webinar on Residential Geothermal Heat Pump Retrofit Transcript

    Broader source: Energy.gov [DOE]

    Transcript for a U.S. Department of Energy Webinar on Dec. 14, 2010, about residential geothermal heat pump retrofits

  11. Short-Term Test Results: Multifamily Home Energy Efficiency Retrofit

    SciTech Connect (OSTI)

    Lyons, J.

    2013-01-01T23:59:59.000Z

    Multifamily deep energy retrofits (DERs) represent great potential for energy savings, while also providing valuable insights on research-generated efficiency measures, cost-effectiveness metrics, and risk factor strategies for the multifamily housing industry. The Bay Ridge project is comprised of a base scope retrofit with a goal of achieving 30% savings (relative to pre-retrofit), and a DER scope with a goal of 50% savings (relative to pre-retrofit). The base scope has been applied to the entire complex, except for one 12-unit building which underwent the DER scope. Findings from the implementation, commissioning, and short-term testing at Bay Ridge include air infiltration reductions of greater than 60% in the DER building; a hybrid heat pump system with a Savings to Investment Ratio (SIR) > 1 (relative to a high efficiency furnace) which also provides the resident with added incentive for energy savings; and duct leakage reductions of > 60% using an aerosolized duct sealing approach. Despite being a moderate rehab instead of a gut rehab, the Bay Ridge DER is currently projected to achieve energy savings ? 50% compared to pre-retrofit, and the short-term testing supports this estimate.

  12. Measure Guideline: Three High Performance Mineral Fiber Insulation Board Retrofit Solutions

    SciTech Connect (OSTI)

    Neuhauser, K.

    2015-01-01T23:59:59.000Z

    This Measure Guideline describes a high performance enclosure retrofit package that uses mineral fiber insulation board. The Measure Guideline describes retrofit assembly and details for wood frame roof and walls and for cast concrete foundations. This Measure Guideline is intended to serve contractors and designers seeking guidance for non-foam exterior insulation retrofit.

  13. Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

    SciTech Connect (OSTI)

    Dentz, J.; Podorson, D.; Varshney, K.

    2014-05-01T23:59:59.000Z

    Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

  14. Low NO{sub x}/SO{sub x} Burner retrofit for utility cyclone boilers. Quarterly technical progress report, June--September 1990

    SciTech Connect (OSTI)

    Not Available

    1990-12-31T23:59:59.000Z

    The objective of this project is to demonstrate the LNS Burner as retrofitted to the host cyclone boiler for effective low-cost control of NO{sub x} and SO{sub x} emissions while firing a bituminous coal. The LNS Burner employs a simple, innovative combustion process to burn pulverized coal at high temperatures and provides effective, low-cost control of sulfur dioxide (SO{sub 2}) and nitrogen oxides (NO{sub x}) emissions. The coal ash contains sulfur and is removed in the form of molten slag and flyash. Cyclone-fired boiler units are typically older units firing high-sulfur bituminous coals at very high temperatures which results in very high NO{sub x} and SO{sub x} emissions. The addition of conventional emission control equipment, such as wet scrubbers, to these older cyclone units in order to meet current and future environmental regulations is generally not economic. Further, the units are generally not compatible with low sulfur coal switching for S0{sub 2} control or selective catalytic reduction technologies for NO{sub x} control. Because the LNS Burner operates at the same very high temperatures as a typical cyclone boiler and produces a similar slag product, it may offer a viable retrofit option for cyclone boiler emission control. This was confirmed by the Cyclone Boiler Retrofit Feasibility Study carried out by TransAlta and an Operating Committee formed of cyclone boiler owners in 1989. An existing utility cyclone boiler, was then selected for the evaluation of the cost and performance study. It was concluded that the LNS Burner retrofit would be a cost-effective option for control of cyclone boiler emissions. A full-scale demonstration of the LNS Burner retrofit was selected in October 1988 as part of the DOE`s Clean Coal Technology Program Round II.

  15. Modular industrial solar retrofit project (MISR)

    SciTech Connect (OSTI)

    Alvis, R.L.

    1980-01-01T23:59:59.000Z

    The intent of this paper is to describe a major Department of Energy (DOE) thrust to bring line-focus solar thermal technology to commercial readiness. This effort is referred to as the MISR Project. The project is based upon the premise that thermal energy is the basic solar thermal system output and that low-temperature, fossil fuel applications are technically the first that should be retrofitted. Experience has shown that modularity in system design and construction offers potential for reducing engineering design costs, reduces manufacturing costs, reduces installation time and expense, and improves system operational reliability. The modular design effort will be sponsored by Sandia National Laboratories with industry doing the final designs. The operational credibility of the systems will be established by allowing selected industrial thermal energy users to purchase MISR systems from suppliers and operate them for two years. Industries will be solicited by DOE/Albuquerque Operations Office to conduct these experiments on a cost sharing basis. The MISR system allowed in the experiments will have been previously qualified for the application. The project is divided into three development phases which represent three design and experiment cycles. The first cycle will use commercially available trough-type solar collectors and will incorporate 5 to 10 experiments of up to 5000 m/sup 2/ of collectors each. The project effort began in March 1980, and the first cycle is to be completed in 1985. Subsequent cycles will begin at 3-year intervals. The project is success oriented, and if the first cycle reaches commercial readiness, the project will be terminated. If not, a second, and possibly a third, development cycle will be conducted.

  16. Pilot Demonstration of Phased Retrofits in Florida Homes (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-08-01T23:59:59.000Z

    The Florida Solar Energy Center (FSEC) and Florida Power and Light are pursuing a collaborative energy research/utility partnership to retrofit a large number of homes using a phased approach. The project is creating detailed data on the energy and economic performance of two levels of home retrofit - simple and deep. Acting as a pilot, this project is expected to provide the information necessary to significantly reduce energy use through much larger community-scale projects in collaboration with utilities, program administrators and other market leader stakeholders.

  17. University of California Policy Personal Protective Equipment

    E-Print Network [OSTI]

    Aluwihare, Lihini

    /technical area is a location where the use or storage of hazardous materials occurs or where equipment may hazardous materials, adjacent to or in proximity to a hazard or in areas where there is a reasonable risk performs work functions with hazardous materials or equipment in a laboratory/technical area. A "worker

  18. Measured Cooling Performance and Potential for Buried Duct Condensation in a 1991 Central Florida Retrofit Home

    SciTech Connect (OSTI)

    Chasar, D.; Withers, C.

    2013-02-01T23:59:59.000Z

    FSEC conducted energy performance monitoring of two existing residences in Central Florida that were undergoing various retrofits. These homes were occupied by FSEC researchers and were fully instrumented to provide detailed energy, temperature, and humidity measurements. The data provided feedback about the performance of two levels of retrofit in two types of homes in a hot-humid climate. This report covers a moderate-level retrofit and includes two years of pre-retrofit data to characterize the impact of improvements. The other home is a 'deep energy retrofit' (detailed in a separate report) that has performed at near zero energy with a photovoltaic (PV) system and extensive envelope improvements.

  19. SCR & DPF RETROFITS FOR MOBILE DIESEL ENGINES

    Broader source: Energy.gov (indexed) [DOE]

    3.56 0.01 0.27 3.56 0.90 795 Composite Baseline 3.01 0.01 0.20 2.99 0.76 760 Baseline Emission Tests (Engine is equipped with DPF) Emissions (gbhp.hr) NMHC+NOx PM CO NOx NO2...

  20. CC® of Retrofitted, Renovated, and Rented Systems and Equipment in Utilities Plants

    E-Print Network [OSTI]

    Xu, C.; Chen, Q.; Claridge, D. E.; Turner, W. D.; Deng, S.

    2005-01-01T23:59:59.000Z

    CASE 2: SOUTH SATTELITE PLANT III (SS3) CHW SYSTEM EXPANSION Site Description P P Chiller #54 Chiller #53 Chiller #52 Chiller #51 PCHWP 53 PCHWP 52 PCHWP 51 SCHWP 54 SCHWP 53 SCHWP 52 SCHWP 51 New Pump New Chiller P P P P P P P P P P P P P P Strainer... Strainer Strainer Figure 5 System Diagram of the Expanded SS3 Chilled Water System The SS3 used to have three electric driven centrifugal chillers with 3,300 tons of total chilling capacity. It is a constant primary/variable secondary system (see...

  1. A Retrofit Tool for Improving Energy Efficiency of Commercial Buildings

    SciTech Connect (OSTI)

    Levine, Mark; Feng, Wei; Ke, Jing; Hong, Tianzhen; Zhou, Nan

    2013-06-06T23:59:59.000Z

    Existing buildings will dominate energy use in commercial buildings in the United States for three decades or longer and even in China for the about two decades. Retrofitting these buildings to improve energy efficiency and reduce energy use is thus critical to achieving the target of reducing energy use in the buildings sector. However there are few evaluation tools that can quickly identify and evaluate energy savings and cost effectiveness of energy conservation measures (ECMs) for retrofits, especially for buildings in China. This paper discusses methods used to develop such a tool and demonstrates an application of the tool for a retrofit analysis. The tool builds on a building performance database with pre-calculated energy consumption of ECMs for selected commercial prototype buildings using the EnergyPlus program. The tool allows users to evaluate individual ECMs or a package of ECMs. It covers building envelope, lighting and daylighting, HVAC, plug loads, service hot water, and renewable energy. The prototype building can be customized to represent an actual building with some limitations. Energy consumption from utility bills can be entered into the tool to compare and calibrate the energy use of the prototype building. The tool currently can evaluate energy savings and payback of ECMs for shopping malls in China. We have used the tool to assess energy and cost savings for retrofit of the prototype shopping mall in Shanghai. Future work on the tool will simplify its use and expand it to cover other commercial building types and other countries.

  2. A Methodology to Measure Retrofit Energy Savings in Commercial Buildings

    E-Print Network [OSTI]

    Kissock, John Kelly

    2008-01-16T23:59:59.000Z

    based on pre-retrofit data sets of less than a full year is investigated. The energy delivery efficiency is introduced to measure the efficiency of air-side systems at meeting the net building load. A preliminary investigation of the use of artificial...

  3. Expert Meeting Report: Retrofit Implementation - A Neighborhood at a Time

    SciTech Connect (OSTI)

    Griffiths, D.

    2012-04-01T23:59:59.000Z

    This report provides information about a Building America expert meeting hosted by research team Consortium for Advanced Residential Buildings on October 25, 2011, in New York City. The meeting discussed several community residential retrofit projects underway across the United States, and included representatives from utilities, energy program implementation firms, affordable housing agencies, and the financing industry.

  4. Building America Webinar: Who's Successfully Doing Deep Energy Retrofits?

    Broader source: Energy.gov [DOE]

    The webinar on June 25, 2014, focused on specific Building America projects that highlighted real-world examples of deep energy retrofits (DER) that are meeting with technical and market success. Presenters focused on technical strategies, modeled and actual performance results, and project costs.

  5. Building America Webinar: Who's Successfully Doing Deep Energy Retrofits?

    Broader source: Energy.gov [DOE]

    The webinar will focus on specific Building America projects and case studies that highlight real-world examples of deep energy retrofits that are meeting with technical and market success. Presenters will focus on technical strategies, modeled and actual performance results, and project costs.

  6. Energy and Indoor Environmental Quality Retrofits in Low-Income

    E-Print Network [OSTI]

    environmental measurements and collect energy consumption data. Based on analyses of the data collected fromEnergy and Indoor Environmental Quality Retrofits in Low-Income Apartments ENVIRONMENTAL ENERGY RESEARCH PIER Environmental Research www.energy.ca.gov/research/environmental August 2011 The Issue

  7. Analysis of Pre-Retrofit Building and Utility Data

    SciTech Connect (OSTI)

    Prahl, D.; Beach, R.

    2014-12-01T23:59:59.000Z

    IBACOS analyzed pre-retrofit daily utility data to sort homes by energy consumption, allowing for better targeting of homes for physical audits. Following ASHRAE Guideline 14 normalization procedures, electricity consumption of 1,166 all electric production-built homes' was modeled. The homes were in two communities -- one built in the 1970s and the other in the mid-2000s.

  8. An actuarial approach to retrofit savings in buildings

    SciTech Connect (OSTI)

    Subbarao, Krishnappa; Etingov, Pavel V.; Reddy, T. A.

    2014-01-01T23:59:59.000Z

    An actuarial method has been developed for determining energy savings from retrofits from energy use data for a number of buildings. This method should be contrasted with the traditional method of using pre- and post-retrofit data on the same building. This method supports the U.S. Department of Energy Building Performance Database of real building performance data and related tools that enable engineering and financial practitioners to evaluate retrofits. The actuarial approach derives, from the database, probability density functions (PDFs) for energy savings from retrofits by creating peer groups for the user’s pre post buildings. From the energy use distribution of the two groups, the savings PDF is derived. This provides the basis for engineering analysis as well as financial risk analysis leading to investment decisions. Several technical issues are addressed: The savings PDF is obtained from the pre- and post-PDF through a convolution. Smoothing using kernel density estimation is applied to make the PDF more realistic. The low data density problem can be mitigated through a neighborhood methodology. Correlations between pre and post buildings are addressed to improve the savings PDF. Sample size effects are addressed through the Kolmogorov--Smirnov tests and quantile-quantile plots.

  9. Seismic Retrofitting of RC Frames with RC Infilling

    E-Print Network [OSTI]

    Seismic Retrofitting of RC Frames with RC Infilling SERIES Workshop: "Role of research infrastructures in seismic rehabilitation" 8 - 9 February 2012, Istanbul, Turkey C. Z. Chrysostomou, N. Kyriakides, P. Kotronis, P. Roussis, M. Poljansek, F. Taucer RC Infilling of Existing RC Structures for Seismic

  10. An Assessment of Envelope Measures in Mild Climate Deep Energy Retrofits

    SciTech Connect (OSTI)

    Walker, Iain; Less, Brennan

    2014-06-01T23:59:59.000Z

    Energy end-uses and interior comfort conditions have been monitored in 11 Deep Energy Retrofits (DERs) in a mild marine climate. Two broad categories of DER envelope were identified: first, bringing homes up to current code levels of insulation and airtightness, and second, enhanced retrofits that go beyond these code requirements. The efficacy of envelope measures in DERs was difficult to determine, due to the intermingled effects of enclosure improvements, HVAC system upgrades and changes in interior comfort conditions. While energy reductions in these project homes could not be assigned to specific improvements, the combined effects of changes in enclosure, HVAC system and comfort led to average heating energy reductions of 76percent (12,937 kWh) in the five DERs with pre-retrofit data, or 80percent (5.9 kWh/ft2) when normalized by floor area. Overall, net-site energy reductions averaged 58percent (15,966 kWh; n=5), and DERs with code-style envelopes achieved average net-site energy reductions of 65percent (18,923 kWh; n=4). In some homes, the heating energy reductions were actually larger than the whole house reductions that were achieved, which suggests that substantial additional energy uses were added to the home during the retrofit that offset some heating savings. Heating system operation and energy use was shown to vary inconsistently with outdoor conditions, suggesting that most DERs were not thermostatically controlled and that occupants were engaged in managing the indoor environmental conditions. Indoor temperatures maintained in these DERs were highly variable, and no project home consistently provided conditions within the ASHRAE Standard 55-2010 heating season comfort zone. Thermal comfort and heating system operation had a large impact on performance and were found to depend upon the occupant activities, so DERs should be designed with the occupants needs and patterns of consumption in mind. Beyond-code building envelopes were not found to be strictly necessary for the achievement of deep energy savings in existing uninsulated homes in mild marine climates, provided that other energy end-uses were comprehensively reduced. We recommend that mild climate DERs pursue envelopes in compliance with the 2012 International Energy Conservation Code (IECC) and pair these with high efficiency, off-the-shelf HVAC equipment. Enhanced building envelopes should be considered in cases where very low heating energy use (<1,000 kWh/year or <0.5 kWh/ft2-year) and enhanced thermal comfort (ASHRAE 55-2010) are required, as well as in those situations where substantial energy uses are added to the home, such as decorative lighting, cooling or smart home A/V and communication equipment.

  11. Energy Audit Equipment

    E-Print Network [OSTI]

    Phillips, J.

    2012-01-01T23:59:59.000Z

    The tools (equipment) needed to perform an energy audit include those items which assist the auditor in measuring the energy used by equipment or lost in inefficiency. Each tool is designed for a specific measurement. They can be inexpensive simple...

  12. Full-scale demonstration of low-NO{sub x} cell{trademark} burner retrofit. Final report

    SciTech Connect (OSTI)

    Eckhart, C.F.; Kitto, J.B.; Kleisley, R.J. [and others

    1994-07-01T23:59:59.000Z

    The objective of the Low-NO{sub x} Cell{trademark}Burner (LNCB{trademark}) demonstration is to evaluate the applicability of this technology for reducing NO{sub x} emissions in full-scale, cell burner-equipped boilers. More precisely, the program objectives are to: (1) Achieve at least a 50% reduction in NO{sub x} emissions. (2) Reduce NO{sub x} with no degradation to boiler performance or life of the unit. (3) Demonstrate a technically and economically feasible retrofit technology. Cell burner equipped boilers comprise 13% of the Pre-New Source Performance Standards (NSPS) coal-fired generating capacity. This relates to 34 operating units generating 23,639 MWe, 29 of which are opposed wall fired with two rows of two-nozzle cell burners on each wall. The host site was one of these 29. Dayton Power & Light offered use of J.M. Stuart Station`s Unit No. 4 as the host site. It was equipped with 24, two-nozzle cell burners arranged in an opposed wall configuration. To reduce NO{sub x} emissions, the LNCB{trademark} has been designed to delay the mixing of the fuel and combustion air. The delayed mixing, or staged combustion, reduces the high temperatures normally generated in the flame of a standard cell burner. A key design criterion for the burner was accomplishing delayed fuel-air mixing with no pressure part modifications to facilitate a {open_quotes}plug-in{close_quotes} design. The plug-in design reduces material costs and outage time required to complete the retrofit, compared to installing conventional, internally staged low-NO{sub x} burners.

  13. High-Efficiency Retrofit Lessons for Retail from a SuperTarget: Preprint

    SciTech Connect (OSTI)

    Langner, R.; Deru, M.; Hirsch, A.; Williams, S.

    2013-02-01T23:59:59.000Z

    The National Renewable Energy Laboratory partnered with Target under the Commercial Building Program to design and implement a retrofit of a SuperTarget in Thornton, CO. The result was a retrofit design that predicted 37% energy savings over ASHRAE Standard 90.1-2004, and 29% compared to existing (pre-retrofit) store consumption. The largest savings came from energy efficient lighting, energy efficient cooling systems, improved refrigeration, and better control of plug loads.

  14. Chamberlain Heights Redevelopment: A Large Scale, Cold Climate Study of Affordable Housing Retrofits

    SciTech Connect (OSTI)

    Donnelly, K.; Mahle, M.

    2012-03-01T23:59:59.000Z

    The City of Meriden Housing Authority (MHA) collaborated with affordable housing developer Jonathon Rose Companies (JRC) to complete a gut renovation of 124 residential units in the Chamberlain Heights retrofit project. The affordable housing community is made up of 36 buildings in duplex and quad configurations located on 22 acres within two miles of downtown Meriden, CT. The final post-retrofit analysis showed 40-45% source energy savings over the existing pre-retrofit conditions.

  15. Resource handbook for low-income residential retrofits

    SciTech Connect (OSTI)

    Callaway, J.W.; Brenchley, D.L.; Davis, L.J.; Ivey, D.L.; Smith, S.A.; Westergard, E.J.

    1987-04-01T23:59:59.000Z

    The purpose of the handbook is to provide technical assistance to state grantees participating in the Partnerships in Low-Income Residential Retrofit (PILIRR) Program. PILIRR is a demonstration program aimed at identifying innovative, successful approaches to developing public and private support for weatherization of low-income households. The program reflects the basic concept that responsibility for financial support for conservation activities such as low-income residential retrofitting is likely to gradually shift from the DOE to the states and the private sector. In preparing the handbook, PNL staff surveyed over 50 programs that provide assistance to low-income residents. The survey provided information on factors that contribute to successful programs. PNL also studied the winning PILIRR proposals (from the states of Florida, Iowa, Kentucky, Oklahoma and Washington) and identified the approaches proposed and the type of information that would be most helpful in implementing these approaches.

  16. Cascade Apartments - Deep Energy Multifamily Retrofit , Kent, Washington (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-02-01T23:59:59.000Z

    In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions : 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofit package after considering utility window incentives and KCHA capitol improvement funding.

  17. Text-Alternative Version of Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings

    Broader source: Energy.gov [DOE]

    A text-alternative version of the Building America webinar, Retrofitting Central Space Conditioning Strategies for Multifamily Buildings held on July 16, 2014.

  18. Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool Webcast

    Broader source: Energy.gov [DOE]

    Below is the text-alternative version of the "Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool" webcast, held April 3, 2012.

  19. Text-Alternative Version: Using the Street and Parking Facility Lighting Retrofit Financial Analysis Tool

    Broader source: Energy.gov [DOE]

    Below is the text-alternative version of the "Using the Street and Parking Facility Lighting Retrofit Financial Analysis Tool" webcast, held August 22, 2013.

  20. Protocol for Maximizing Energy Savings and Indoor Environmental Quality Improvements when Retrofitting Apartments

    SciTech Connect (OSTI)

    Noris, Federico; Delp, William W.; Vermeer, Kimberly; Adamkiewicz, Gary; Singer, Brett C.; Fisk, William J.

    2012-06-18T23:59:59.000Z

    The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

  1. Performance of a Hot-Dry Climate Whole-House Retrofit

    SciTech Connect (OSTI)

    Weitzel, E.; German, A.; Porse, E.

    2014-06-01T23:59:59.000Z

    The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.

  2. Case study field evaluation of a systems approach to retrofitting a residential HVAC system

    E-Print Network [OSTI]

    Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

    2003-01-01T23:59:59.000Z

    Practices for Residential HVAC Systems”. Boston, MA. Jump,techniques for measuring HVAC grille air flows". ASHRAEPractices Guide for Residential HVAC Retrofits. LBNL 53592.

  3. Energy Efficient Crawlspace Foundation Retrofit: Mixed Humid Climate

    SciTech Connect (OSTI)

    Del Bianco, M.; Wiehagen, J.; Wood, A.

    2013-01-01T23:59:59.000Z

    Residential quality management systems have most often been designed for new home construction. To address quality in existing homes in the form of Scopes of Work (SOW), the NAHB Research Center began with a new construction scope of work and applied it to an existing home project. This document is intended to outline the steps of translating a new home construction SOW to SOW for retrofit.

  4. Retrofit Analysis of Older, Single Family Housing in San Antonio

    E-Print Network [OSTI]

    Rashed-Ali, H.

    2013-01-01T23:59:59.000Z

    of San Antonio has 28 historic districts, • Potential energy savings from retrofit of older homes are substantial and undisputed. However: • Historic homes need thoughtful attention to the details and features that cause society to give them protected... listings due to their cultural heritage value. Front porch of case study home 1 ESL-KT-13-12-05 CATEE 2013: Clean Air Through Energy Efficiency Conference, San Antonio, Texas Dec. 16-18 Background • An energy efficient and sustainable building can reduce...

  5. Commissioning of the Fresno, California, Retrofit Unoccupied Test House

    SciTech Connect (OSTI)

    Stecher, D.; Imm, C.

    2013-06-01T23:59:59.000Z

    Commissioning of instrumentation and limited short-term testing have been completed on a retrofit unoccupied test house in Fresno, California. This house is intended to be used as a laboratory in which several different methods of space conditioning distribution will be evaluated. This report provides background on the project, including specifications of the house and models used in its development, along with models to be evaluated through its operation.

  6. Continuous Commissioning: A Valuable Partner to Retrofit Projects

    E-Print Network [OSTI]

    Turner, W. D.; Banks, K.; Athar, A.; Yazdani, B.; Zhu, Y.; Culp, C.

    2001-01-01T23:59:59.000Z

    -hand corner. Prior to commissioning, any changes in the duct static pressure or discharge air temperature setpoints did not affect the VFD speed. The operation of five AHUs was analyzed using the data collected through the EMCS. Table 2 presents summarized... variable frequency drives on constant speed motors and installing/modifying the DDC control system to control and optimize operation and to improve the system efficiency. In most cases, the retrofit projects realize their projected energy savings...

  7. Next Step Toward Widespread Residential Deep Energy Retrofits

    SciTech Connect (OSTI)

    McIlvaine, J.; Saunders, S.; Bordelon, E.; Baden, S.; Elam, L.; Martin, E.

    2013-07-01T23:59:59.000Z

    The complexity of deep energy retrofits warrants additional training to successfully manage multiple improvements that will change whole house air, heat, and moisture flow dynamics. The home performance contracting industry has responded to these challenges by aggregating skilled labor for assessment of and implementation under one umbrella. Two emerging business models are profiled that seek to resolve many of the challenges, weaknesses, opportunities, and threats described for the conventional business models.

  8. Passive solar retrofit: an investment for the future

    SciTech Connect (OSTI)

    Balcomb, S.A.

    1980-01-01T23:59:59.000Z

    America has a large inventory of older buildings which are directly contributing to the energy crunch. These liabilities could be converted to assets with the proper application of conservation and solar techniques. Through the use of one typical example, the economic and social benefits of such a conversion are discussed. A somewhat unusual method of financing is described, and a set of economic criteria often overlooked in the evaluation of a solar retrofit potential is addressed.

  9. Deep Energy Retrofit Performance Metric Comparison: Eight California Case Studies

    SciTech Connect (OSTI)

    Walker, Iain; Fisher, Jeremy; Less, Brennan

    2014-06-01T23:59:59.000Z

    In this paper we will present the results of monitored annual energy use data from eight residential Deep Energy Retrofit (DER) case studies using a variety of performance metrics. For each home, the details of the retrofits were analyzed, diagnostic tests to characterize the home were performed and the homes were monitored for total and individual end-use energy consumption for approximately one year. Annual performance in site and source energy, as well as carbon dioxide equivalent (CO{sub 2}e) emissions were determined on a per house, per person and per square foot basis to examine the sensitivity to these different metrics. All eight DERs showed consistent success in achieving substantial site energy and CO{sub 2}e reductions, but some projects achieved very little, if any source energy reduction. This problem emerged in those homes that switched from natural gas to electricity for heating and hot water, resulting in energy consumption dominated by electricity use. This demonstrates the crucial importance of selecting an appropriate metric to be used in guiding retrofit decisions. Also, due to the dynamic nature of DERs, with changes in occupancy, size, layout, and comfort, several performance metrics might be necessary to understand a project’s success.

  10. Forrestal Building Lighting Retrofit Second Live Test Demonstration (LTD)

    SciTech Connect (OSTI)

    Halverson, M.A.; Schmelzer, J.R.; Parker, G.B.

    1993-02-01T23:59:59.000Z

    This report describes and summarizes the Forrestal Building Lighting Retrofit Live Test demonstration (LTD) performed by Pacific Northwest Laboratory (PNL) in Room 5E-080 of the DOE Forrestal Building in Washington, D.C. The purpose of the LTD was to evaluate proposed lighting retrofits for compliance with the requirements laid out in the request for proposal (RFP) for the Shared Energy Savings (SES) Lighting Retrofit Project for the Forrestal Building, Washington, D.C. Testing was conducted from March 9 through March 18, 1992, and again on August 3 through August 6, 1992. Four contractors were initially tested in March. Then, two contractors were retested in August due to changes in the rebate schedule for electronic ballasts being offered by the Potomac Electric Power Company (PEPCO), the utility servicing the Forrestal Building. The two contractors tested in March were retested with different ballasts, tubes, and reflectors. The results from these new tests are reported here and compared with those from the earlier tests.

  11. Field Assessment of Energy Audit Tools for Retrofit Programs

    SciTech Connect (OSTI)

    Edwards, J.; Bohac, D.; Nelson, C.; Smith, I.

    2013-07-01T23:59:59.000Z

    This project focused on the use of home energy ratings as a tool to promote energy retrofits in existing homes. A home energy rating provides a quantitative appraisal of a home's asset performance, usually compared to a benchmark such as the average energy use of similar homes in the same region. Home rating systems can help motivate homeowners in several ways. Ratings can clearly communicate a home's achievable energy efficiency potential, provide a quantitative assessment of energy savings after retrofits are completed, and show homeowners how they rate compared to their neighbors, thus creating an incentive to conform to a social standard. An important consideration is how rating tools for the retrofit market will integrate with existing home energy service programs. For residential programs that target energy savings only, home visits should be focused on key efficiency measures for that home. In order to gain wide adoption, a rating tool must be easily integrated into the field process, demonstrate consistency and reasonable accuracy to earn the trust of home energy technicians, and have a low monetary cost and time hurdle for homeowners. Along with the Home Energy Score, this project also evaluated the energy modeling performance of SIMPLE and REM/Rate.

  12. An Experimental and Analytical Evaluation of Wall And Window Retrofit Configurations: Supporting the Residential Retrofit Best Practices Guide

    SciTech Connect (OSTI)

    Stovall, Therese K [ORNL; Petrie, Thomas [ORNL; Kosny, Jan [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL; Hulvey, Kimberly D [ORNL

    2007-11-01T23:59:59.000Z

    A Retrofit Best Practices Guide was developed to encourage homeowners to consider energy conservation issues whenever they modify their siding or windows. In support of this guide, an experimental program was implemented to measure the performance of a number of possible wall siding and window retrofit configurations. Both thermal and air-leakage measurements were made for a 2.4 x 2.4 m (8 x 8 ft) wall section with and without a 0.9 x 1.2 m (3 x 4 ft) window. The windows tested were previously well-characterized at a dedicated window test facility. A computer model was also used to provide information for the Best Practices Guide. The experimental data for walls and windows were used in conjunction with this model to estimate the total annual energy savings for several typical houses in a number of different locations.

  13. Decision analysis for seismic retrofit of structures

    E-Print Network [OSTI]

    Williams, Ryan J.

    2009-05-15T23:59:59.000Z

    of earthquakes as deterministic statements that will not occur for a long time rather than as probabilistic statements about the events (May 2004). Due to the aforementioned concerns regarding the decreased likelihood of building damage from seismic activity...-05, American Society of Civil Engineers, Reston, VA. Bai, J.-W., Hueste, M. B., and Gardoni, P. (2007). ?A probabilistic framework for the assessment of structural losses due to seismic events.? J. Struct. Engrg., submitted for review. Bracci, J. M...

  14. Incidents of chemical reactions in cell equipment

    SciTech Connect (OSTI)

    Baldwin, N.M.; Barlow, C.R. [Uranium Enrichment Organization, Oak Ridge, TN (United States)

    1991-12-31T23:59:59.000Z

    Strongly exothermic reactions can occur between equipment structural components and process gases under certain accident conditions in the diffusion enrichment cascades. This paper describes the conditions required for initiation of these reactions, and describes the range of such reactions experienced over nearly 50 years of equipment operation in the US uranium enrichment program. Factors are cited which can promote or limit the destructive extent of these reactions, and process operations are described which are designed to control the reactions to minimize equipment damage, downtime, and the possibility of material releases.

  15. Sector 1 - Equipment

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    APS detector pool has a number of additional detectors Furnaces Powder diffraction furnace Infrared furnace Plate furnace Mechanical Testing Equipment The following mechanical...

  16. Text-Alternative Version of Building America Webinar: Low-e Storms: The Next "Big Thing" in Window Retrofits

    Broader source: Energy.gov [DOE]

    Low-e Storms:  The Next “Big Thing” in Window RetrofitsOfficial Webinar Transcript (September 9, 2014)

  17. Direct Liquid Cooling for Electronic Equipment

    SciTech Connect (OSTI)

    Coles, Henry; Greenberg, Steve

    2014-03-01T23:59:59.000Z

    This report documents a demonstration of an electronic--equipment cooling system in the engineering prototype development stage that can be applied in data centers. The technology provides cooling by bringing a water--based cooling fluid into direct contact with high--heat--generating electronic components. This direct cooling system improves overall data center energy efficiency in three ways: High--heat--generating electronic components are more efficiently cooled directly using water, capturing a large portion of the total electronic equipment heat generated. This captured heat reduces the load on the less--efficient air--based data center room cooling systems. The combination contributes to the overall savings. The power consumption of the electronic equipment internal fans is significantly reduced when equipped with this cooling system. The temperature of the cooling water supplied to the direct cooling system can be much higher than that commonly provided by facility chilled water loops, and therefore can be produced with lower cooling infrastructure energy consumption and possibly compressor-free cooling. Providing opportunities for heat reuse is an additional benefit of this technology. The cooling system can be controlled to produce high return water temperatures while providing adequate component cooling. The demonstration was conducted in a data center located at Lawrence Berkeley National Laboratory in Berkeley, California. Thirty--eight servers equipped with the liquid cooling system and instrumented for energy measurements were placed in a single rack. Two unmodified servers of the same configuration, located in an adjacent rack, were used to provide a baseline. The demonstration characterized the fraction of heat removed by the direct cooling technology, quantified the energy savings for a number of cooling infrastructure scenarios, and provided information that could be used to investigate heat reuse opportunities. Thermal measurement data were used with data center energy use modeling software to estimate overall site energy use. These estimates show that an overall data center energy savings of approximately 20 percent can be expected if a center is retrofitted as specified in the models used. Increasing the portion of heat captured by this technology is an area suggested for further development.

  18. Water Efficiency Improvements at Various Environmental Protection Agency Sites: Best Management Practice Case Study #12 - Laboratory/Medical Equipment (Brochure)

    SciTech Connect (OSTI)

    Blakley, H.

    2011-03-01T23:59:59.000Z

    The U.S. Environmental Protection Agency (EPA) built a successful water conservation program and reduced potable water use through a series of initiatives at EPA laboratories. The projects highlighted in this case study demonstrate EPA's ability to reduce water use in laboratory and medical equipment by implementing vacuum pump and steam sterilizer replacements and retrofits. Due to the success of the initial vacuum pump and steam sterilizer projects described here, EPA is implementing similar projects at several laboratories throughout the nation.

  19. Measured energy savings and economics of retrofitting existing single- family homes: An update of the BECA-B database

    SciTech Connect (OSTI)

    Cohen, S.D.; Goldman, C.A.; Harris, J.P.

    1991-02-01T23:59:59.000Z

    These appendices are the companion volume to report number LBL--28147 Vol.1, with the same title. The summary data tables include physical characteristics, energy consumption, savings, and the retrofit measures installed and their costs for each retrofit project. Each existing single family residential building'' retrofit project in the BECA-B database is described. 99 refs. (BM)

  20. RETROFIT: A SOFTWARE TO SOLVE OPTIMIZATION AND IDENTIFICATION PROBLEMS APPLIED TO BUILDING ENERGY

    E-Print Network [OSTI]

    Boyer, Edmond

    RETROFIT: A SOFTWARE TO SOLVE OPTIMIZATION AND IDENTIFICATION PROBLEMS APPLIED TO BUILDING ENERGY the software ReTrofiT that specifically treats this kind of problems applied to building energy performance mod, inverse problems. INTRODUCTION Energy management systems in buildings greatly contribute

  1. SOLAR ICE CREAM: ACHIEVING NET-ZERO THROUGH AN INTEGRATED RETROFIT Sara Tepfer

    E-Print Network [OSTI]

    SOLAR ICE CREAM: ACHIEVING NET-ZERO THROUGH AN INTEGRATED RETROFIT APPROACH Sara Tepfer-3). One such strategy is Net-zero energy design (NetZED), which can be applied to new construction and to develop a net-zero retrofit for this establishment which integrates onsite renewable energy sources

  2. Retrofitting Vegas: Implementing Energy Efficiency in Two Las Vegas Test Homes

    SciTech Connect (OSTI)

    Puttagunta, S.

    2013-04-01T23:59:59.000Z

    In 2009, the state of Nevada received nearly forty million dollars in Neighborhood Stabilization Funds from the Department of Housing and Urban Development. The purpose of this funding was to stabilize communities that have suffered from foreclosures and abandonment. In an effort to provide guidance to local officials and maximize how effectively this NSP funding is utilized in retrofitting homes, CARB provided design specifications, energy modeling, and technical support for the Building America Retrofit Alliance (BARA) team and its local partners - Better Building Performance, Nevada Energy Star Partners Green Alliance, and Home Free Nevada - for two retrofit test homes. One home was to demonstrate a modest retrofit and the other a deep energy retrofit. Through this project, CARB has provided two robust solution packages for retrofitting homes built in this region between the 1980s and early 1990s without substantially inconveniencing the occupants. The two test homes, the Carmen and Sierra Hills, demonstrate how cost-effectively energy efficient upgrades can be implemented in the hot, dry climate of the Southwest. In addition, the homes were used as an educational experience for home performance professionals, building trades, remodelers, and the general public. In-field trainings on air-sealing, HVAC upgrades, and insulating were provided to local contractors during the retrofit and BARA documented these retrofits through a series of video presentations, beginning with a site survey and concluding with the finished remodel and test out.

  3. Expert Meeting Report: Interior Insulation Retrofit of Mass Masonry Wall Assemblies

    SciTech Connect (OSTI)

    Ueno, K.; Van Straaten, R.

    2012-02-01T23:59:59.000Z

    The Building Science Consortium held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011 at the Westford Regency Hotel in Westford, MA. This report outlines the extensive information that was presented on assessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce such risks.

  4. Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit

    E-Print Network [OSTI]

    Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit Wanyu R. Chan, Jeffrey,000 single-family detached homes have sufficient information for the analysis of air leakage in relation variability in normalized leakage. ResDB also contains the before and after retrofit air leakage measurements

  5. The USDOE Forrestal Building Lighting Retrofit: Preliminary Analysis of Electricity Savings

    E-Print Network [OSTI]

    Haberl, J. S.; Bou-Saada, T. E.; Vajda, E. J.; Shincovich, M.; D'Angelo III, L.; Harris, L.

    1994-01-01T23:59:59.000Z

    In September of 1993 a 36,832 fixture lighting retrofit was completed at the United States Department of Energy Forrestal complex in Washington, D.C. This retrofit represents DOE's largest project to date that utilizes a Shared Energy Savings (SES...

  6. ENERGY IMPACTS OF ENERGY AND INDOOR ENVIRONMENTAL QUALITY RETROFITS OF APARTMENTS IN CALIFORNIA

    E-Print Network [OSTI]

    .S. is implementing many energy retrofits in homes with the goal of reducing building energy consumption and carbon1 ENERGY IMPACTS OF ENERGY AND INDOOR ENVIRONMENTAL QUALITY RETROFITS OF APARTMENTS IN CALIFORNIA Environment Group, Berkeley, CA, USA Corresponding author: William J. Fisk 1 Cyclotron Road, 90R3058 Lawrence

  7. Sonoma House: Monitoring of the First U.S. Passive House Retrofit

    SciTech Connect (OSTI)

    German, A.; Weitzel, B.; Backman, C.; Hoeschele, M.; Dakin, B.

    2012-12-01T23:59:59.000Z

    The Sonoma Deep Retrofit is a single-story deep retrofit project in the marine climate of Sonoma, California. The design was guided by Passive House principles which promote the use of very high levels of wall, ceiling, and floor insulation along with tight envelope construction to maintain a comfortable indoor environment with little or no need for conventional heating or cooling.

  8. Exploring Cost-Effective, High Performance Residential Retrofits for Affordable Housing in the Hot Humid Climate

    E-Print Network [OSTI]

    McIlvaine, J.; Sutherland, K.; Chandra, S.; Schleith, K.

    , and programmable thermostats. Further, they are ? Figure 5 Typical attic insulation pre- retrofit (top) and post-retrofit (bottom) ESL-HH-10-08-17 ? 10? ? requiring duct leakage tests to be performed on all homes with a goal of 6 cfm or less...

  9. Seismic retrofit of concrete-encased riveted stiffened seat angle connections

    E-Print Network [OSTI]

    Bruneau, Michel

    Seismic retrofit of concrete-encased riveted stiffened seat angle connections Michel Bruneau Ottawa: Seismic retrofit, semi-rigid connections, concrete-encased, stiffened seat, ductile steel fuse, riveted frequently found in buildings constructed in the seismic zones of Eastern North America prior

  10. Results from Development of Model Specifications for Multifamily Energy Retrofits

    SciTech Connect (OSTI)

    Brozyna, K.

    2012-08-01T23:59:59.000Z

    Specifications, modeled after CSI MasterFormat, provide the trade contractors and builders with requirements and recommendations on specific building materials, components and industry practices that comply with the expectations and intent of the requirements within the various funding programs associated with a project. The goal is to create a greater level of consistency in execution of energy efficiency retrofits measures across the multiple regions a developer may work. IBACOS and Mercy Housing developed sample model specifications based on a common building construction type that Mercy Housing encounters.

  11. Newporter Apartments: Deep Energy Retrofit Short-Term Results

    SciTech Connect (OSTI)

    Gordon, A.; Howard, L.; Kunkle, R.; Lubliner, M.; Auer, D.; Clegg, Z.

    2012-12-01T23:59:59.000Z

    This project demonstrates a path to meet the goal of the Building America program to reduce home energy use by 30% in multi-family buildings. The project demonstrates cost effective energy savings targets as well as improved comfort and indoor environmental quality (IEQ) associated with deep energy retrofits by a large public housing authority as part of a larger rehabilitation effort. The project focuses on a typical 1960's vintage low-rise multi-family apartment community (120 units in three buildings).

  12. Glove port retrofit assembly and method of replacing components

    DOE Patents [OSTI]

    Giesen, Isaac M; Cournoyer, Michael E; Rael, David G

    2014-11-18T23:59:59.000Z

    What is disclosed is a system for retrofitting a sealed enclosure for performing work therein having an outer enclosure assembly configured to be clamped to the outer annular face of a port ring and form a sealed engagement with the outer annular surface of the port ring, a change assembly having an inner ring and an access element wherein the inner ring has a first annular cylinder body that is sized to be slidably received by the port ring and the access element is configured to be sealably and slidably positioned within the first annular cylinder body of the inner ring.

  13. Retrofit Program Lead-by-Example Resources | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingof EnhancedRestructuringNinthRetrofit Program

  14. Retrofit Ramp-Up Selected Projects* | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingof EnhancedRestructuringNinthRetrofit

  15. Retrofitting Doors on Open Refrigerated Cases | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingofRetrofitting Doors on Open Refrigerated Cases

  16. Expert Meeting Report: Retrofit Implementation - A Neighborhood at a Time

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: Final EnvironmentalCounties,UnitedCommunication,1] U.S.EducationalJanuaryKeyRetrofit

  17. Program Management on Multifamily Retrofits | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMay 2015 < prev next > SunChallengeHydrotreatingMultifamily Retrofits

  18. Retrofitting Doors on Open Refrigerated Cases | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMay 2015 <Department of EnvironmentalRetiringWeatherizationRetrofitting

  19. Data Center Airflow Management Retrofit | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny:Revised Finding of No53197 This work was performedEnergy DataEnergyRetrofit

  20. NREL Job Task Analysis: Retrofit Installer Technician | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin of Contamination in Many Devils Wash,Energy NREL Job Task Analysis: Retrofit Installer

  1. field_equipment.indd

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    FIELD EQUIPMENT INVENTORY Trucks * Five vacpressure trucks, 60-90 bbl, up to 5 bpm at 5,000 lb. * Waterfi re truck, 110 bbl * Two dump trucks: 5-yard and 12-yard * Belly dump...

  2. Applied methods to verify LP turbine performance after retrofit

    SciTech Connect (OSTI)

    Overby, R. [Florida Power and Light Co., Juno Beach, FL (United States); Lindberg, G. [ABB Power Generation, Baden (Switzerland)

    1996-12-31T23:59:59.000Z

    With increasing operational hours of power plants, many utilities may find it necessary to replace turbine components, i.e., low pressure turbines. In order to decide between different technical and economic solutions, the utility often takes the opportunity to choose between an OEM or non-OEM supplier. This paper will deal with the retrofitting of LP turbines. Depending on the scope of supply the contract must define the amount of improvement and specifically how to verify this improvement. Unfortunately, today`s Test Codes, such as ASME PTC 6 and 6.1, do not satisfactorily cover these cases. The methods used by Florida Power and Light (FP and L) and its supplier to verify the improvement of the low pressure turbine retrofit at the Martin No. 1 and Sanford No. 4 units will be discussed and the experience gained will be presented. In particular the influence of the thermal cycle on the applicability of the available methods will be analyzed and recommendations given.

  3. Performance Results for Massachusetts and Rhode Island Deep Energy Retrofit Pilot Community

    SciTech Connect (OSTI)

    Gates, C.; Neuhauser, K.

    2014-03-01T23:59:59.000Z

    Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent 'package' of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilot participants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

  4. National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-03-01T23:59:59.000Z

    Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent "package" of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilot participants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

  5. Test Methods and Protocols for Environmental and Safety Hazards Associated with Home Energy Retrofits

    SciTech Connect (OSTI)

    Cautley, D.; Viner, J.; Lord, M.; Pearce, M.

    2012-12-01T23:59:59.000Z

    A number of health hazards and hazards to the durability of homes may be associated with energy retrofitting and home renovation projects. Among the hazards associated with energy retrofit work, exposure to radon is thought to cause more than 15,000 deaths per year in the U.S., while carbon monoxide poisoning results in about 20,000 injuries and 450 deaths per year. Testing procedures have been developed for identifying and quantifying hazards during retrofitting. These procedures commonly include a battery of tests to screen combustion appliances for safe operation, including worst case depressurization measurement, backdrafting (spillage) under depressurized or normal conditions, and carbon monoxide production.

  6. Standard Measurement and Verification Plan for Lighting Retrofit Projects for Buildings and Building Sites

    SciTech Connect (OSTI)

    Richman, Eric E.

    2012-10-31T23:59:59.000Z

    This document provides a framework for standard measurement and verification (M&V) of lighting retrofit and replacement projects. It was developed to provide site owners, contractors, and other involved organizations with the essential elements of a robust M&V plan for lighting projects. It includes details on all aspects of effectively measuring light levels of existing and post-retrofit projects, conducting power measurement, and developing cost-effectiveness analysis. This framework M&V plan also enables consistent comparison among similar lighting projects, and may be used to develop M&V plans for non--lighting-technology retrofits and new installations.

  7. Equipment Operational Requirements

    SciTech Connect (OSTI)

    Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

    2009-06-11T23:59:59.000Z

    The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

  8. An Overview of Measured Energy Retrofit Savings Methodologies Developed in the Texas LoanSTAR Program

    E-Print Network [OSTI]

    Reddy, T. A.; Kissock, J. K.; Katipamula, S.; Ruch, D. K.; Claridge, D. E.

    1994-01-01T23:59:59.000Z

    Development of methodologies to determine energy retrofit savings in commercial buildings (institutional buildings, schools, hospitals, offices, county and state buildings,...) has been the object of active research during the last 5 years...

  9. Building America Webinar: Low-E Storms: The Next Big Thing in Window Retrofits

    Broader source: Energy.gov [DOE]

    Until recently, energy-efficient window retrofit options have largely been limited to repair or replacement; leaving the homeowner to decide between affordability and deeper energy savings.  A new...

  10. State-of-the-Art Thermal Energy Storage Retrofit at a Large Manufacturing Facility

    E-Print Network [OSTI]

    Fiorino, D.

    This paper will describe the existing conditions, strategic planning, feasibility study, economic analysis, design, specification, construction, and project management for the 2.9 megawatt “full shift” chilled water thermal energy storage retrofit...

  11. Retrofitting a Greenhouse for Energy Conservation Bruce L. Parker, Margaret Skinner, Cheryl F. Sullivan & Donald Tobi

    E-Print Network [OSTI]

    Vermont, University of

    1 Retrofitting a Greenhouse for Energy Conservation Bruce L. Parker, Margaret Skinner, Cheryl F in the greenhouse to keep air circulating properly (Fig. 12). It is good for energy conservation and disease

  12. Determination of Retrofit Savings Using a Calibrated Building Energy Simulation Model

    E-Print Network [OSTI]

    Reddy, S. N.; Hunn, B. D.; Hood, D. B.

    1994-01-01T23:59:59.000Z

    This paper presents the development of a methodology to determine retrofit energy savings in buildings when few measured preretrofit data are available. Calibration of the DOE-2 building energy analysis computer program for a 250,000 ft2 building...

  13. Effects of moisture on debonding in FRP-retrofitted concrete systems

    E-Print Network [OSTI]

    Tuakta, Chakrapan, 1980-

    2011-01-01T23:59:59.000Z

    FRP (fiber reinforced polymer) retrofit systems for reinforced concrete (RC) structures have been widely used in the past 10 years, and numerous studies on its short-term debonding behavior have been conducted extensively. ...

  14. NASA Ames Saves Energy and Reduces Project Costs with Non-Invasive Retrofit Technologies

    Broader source: Energy.gov [DOE]

    Presentation—given at the Fall 2011 Federal Utility Partnership Working Group (FUPWG) meeting—covers the NASA Ames Research Center's effort to save energy and reduce project costs with non-invasive retrofit technologies.

  15. Webcast: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool

    Broader source: Energy.gov [DOE]

    This April 3, 2012 webcast presented information about the Retrofit Financial Analysis Tool developed by DOE"s Municipal Solid-State Street Lighting Consortium. Doug Elliott of Pacific Northwest...

  16. Using the Street and Parking Facility Lighting Retrofit Financial Analysis Tool

    Broader source: Energy.gov [DOE]

    This August 22, 2013 webinar provided a guided walk-through of the Street and Parking Facility Lighting Retrofit Financial Analysis Tool. Developed by a partnership of the DOE Municipal Solid-State...

  17. Cost Savings and Energy Reduction: Bi-Level Lighting Retrofits in Multifamily Buildings

    E-Print Network [OSTI]

    Ackley, J.

    2010-01-01T23:59:59.000Z

    Community Environmental Center implements Bi- Level Lighting fixtures as a component of cost-effective multifamily retrofits. These systems achieve substantial energy savings by automatically reducing lighting levels when common areas are unoccupied...

  18. Seismic fragility and retrofitting for a reinforced concrete flat-slab structure

    E-Print Network [OSTI]

    Bai, Jong-Wha

    2004-09-30T23:59:59.000Z

    The effectiveness of seismic retrofitting applied to enhance seismic performance was assessed for a five-story reinforced concrete (RC) flat-slab building structure in the central United States. In addition to this, an assessment of seismic...

  19. Trial Demonstration of Area Lighting Retrofit: Yuma Border Patrol, Yuma Arizona

    SciTech Connect (OSTI)

    Wilkerson, Andrea M.; McCullough, Jeffrey J.

    2014-12-30T23:59:59.000Z

    The Yuma Sector Border Patrol Area is a high flux lighting application in a high temperature environment, presenting a formidable challenge for light-emitting diodes (LEDs). This retrofit is an Energy Savings Performance Contract ENABLE project under the U.S. Department of Energy (DOE) Federal Energy Management Program. If high flux LED technology performs well in a region with high ambient temperature and solar radiation, it can perform well in most outdoor environments. The design process for the Yuma retrofit has already provided valuable knowledge to CBP and DOE. The LED lighting system selected for the retrofit is expected to reduce energy consumption 69% compared to the incumbent quartz metal halide (QMH) lighting system. If the LED lighting system is installed, GATEWAY will continue to document and disseminate information regarding the installation and long-term performance so that others may also gain valuable knowledge from the Yuma Sector Border Patrol Area lighting retrofit.

  20. An Overview of Measured Energy Retrofit Savings Methodologies Developed in the Texas LoanSTAR Program 

    E-Print Network [OSTI]

    Reddy, T. A.; Kissock, J. K.; Katipamula, S.; Ruch, D. K.; Claridge, D. E.

    1994-01-01T23:59:59.000Z

    Development of methodologies to determine energy retrofit savings in commercial buildings (institutional buildings, schools, hospitals, offices, county and state buildings,...) has been the object of active research during the last 5 years...

  1. Calculating Energy and Demand Retrofit Savings for Stroman High School: Interim Report 

    E-Print Network [OSTI]

    Liu, Y.; Reddy, T. A.; Katipamula, S.; Claridge, D. E.

    1992-01-01T23:59:59.000Z

    computed by two different approaches: Unnormalized Utility Bill Comparison and Weather and Schedule Normalized Utility Bill Comparison Using Post-Retrofit Daily Models. (For purpose of simplicity, in this report, we will refer them as Level-0 and Level-1...

  2. Analysis Methodology for Large Organizations' Investments in Energy Retrofit of Buildings 

    E-Print Network [OSTI]

    Heo, Y.; Augenbroe, G.

    2011-01-01T23:59:59.000Z

    This paper presents a formal methodology that supports large organizations' investments in energy retrofit of buildings. The methodology is a scalable modeling approach based on normative models and Bayesian calibration. Normative models are a light...

  3. Using auxiliary gas power for CCS energy needs in retrofitted coal power plants

    E-Print Network [OSTI]

    Bashadi, Sarah (Sarah Omer)

    2010-01-01T23:59:59.000Z

    Post-combustion capture retrofits are expected to a near-term option for mitigating CO 2 emissions from existing coal-fired power plants. Much of the literature proposes using power from the existing coal plant and thermal ...

  4. Determination of Retrofit Savings Using a Calibrated Building Energy Simulation Model 

    E-Print Network [OSTI]

    Reddy, S. N.; Hunn, B. D.; Hood, D. B.

    1994-01-01T23:59:59.000Z

    This paper presents the development of a methodology to determine retrofit energy savings in buildings when few measured preretrofit data are available. Calibration of the DOE-2 building energy analysis computer program for a 250,000 ft2 building...

  5. Modelling Urban scale Retrofit, Pathways to 2050 Low Carbon Residential Building Stock 

    E-Print Network [OSTI]

    Lannon, Simon; Georgakaki, Aliki; Macdonald, Stuart

    A bottom up engineering modelling approach has been used to investigate the pathways to 2050 low carbon residential building stock. The impact of housing retrofit, renewable technologies, occupant behaviour, and grid decarbonisation is measured at a...

  6. Retrofit of the Local 150 of International Union of Operating Engineers

    Broader source: Energy.gov [DOE]

    Project objectives: Demonstrate the reduced first cost impact of smart geothermal design and technology. Demonstrate smart geothermal innovations in system efficiency, especially in the building-earth interaction. Demonstrate an economical and repeatable approach to district, hybrid retrofit GHP systems.

  7. National Residential Efficiency Measures Database Aimed at Reducing Risk for Residential Retrofit Industry (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-01-01T23:59:59.000Z

    This technical highlight describes NREL research to develop a publicly available database of energy retrofit measures containing performance characteristics and cost estimates for nearly 3,000 measures. Researchers at the U.S. Department of Energy (DOE) National Renewable Energy Laboratory (NREL) have developed the National Residential Efficiency Measures Database, a public database that characterizes the performance and costs of common residential energy efficiency measures. The data are available for use in software programs that evaluate cost-effective retrofit measures to improve the energy efficiency of residential buildings. The database provides a single, consistent source of current data for DOE and private-sector energy audit and simulation software tools and the retrofit industry. The database will reduce risk for residential retrofit industry stakeholders by providing a central, publicly vetted source of up-to-date information.

  8. Analysis Methodology for Large Organizations' Investments in Energy Retrofit of Buildings

    E-Print Network [OSTI]

    Heo, Y.; Augenbroe, G.

    2011-01-01T23:59:59.000Z

    This paper presents a formal methodology that supports large organizations' investments in energy retrofit of buildings. The methodology is a scalable modeling approach based on normative models and Bayesian calibration. Normative models are a light...

  9. Building Retrofits: Energy Conservation and Employee Retention Considerations in Medium-Size Commercial Buildings

    E-Print Network [OSTI]

    Freeman, Janice

    2013-04-29T23:59:59.000Z

    foot per year ($5.60 per square meter per year ) in energy costs (Booz Allen Hamilton, 2009). There is considerable research into building efficiency and expected energy savings resulting from building retrofits: Rocky Mountain Institute estimates...

  10. Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst...

    Broader source: Energy.gov (indexed) [DOE]

    Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst on a Tier 0, SD60M Freight Locomotive Achieving Over 50% PM Reduction Don Newburry Research & Development Manager...

  11. Assessing methods for predicting retrofit energy savings in buildings : case study of a Norwegian school

    E-Print Network [OSTI]

    Ricker, Elizabeth, S.M. (Elizabeth Ann). Massachusetts Institute of Technology

    2008-01-01T23:59:59.000Z

    This work investigates methods for predicting retrofit energy savings in existing Norwegian buildings. A case study is performed on a 30 year old primary school in Trondheim, Norway. The energy consumption in the school ...

  12. Seismic Assessment and Retrofit of Existing Multi-Column Bent Bridges

    E-Print Network [OSTI]

    Seismic Assessment and Retrofit of Existing Multi-Column Bent Bridges By Cole C. Mc ................................................................................................................................... 6 Seismic Activity in Western Washington State Approach ­ Bridge Modeling .............................................11 Seismic Excitations

  13. Lighting retrofit monitoring for the Federal sector-strategies and results at the DOE Forrestal Building

    SciTech Connect (OSTI)

    Halverson, M.A.; Schmelzer, J.R.; Keller, J.M.; Stoops, J.L.; Chvala, W.D.

    1994-08-01T23:59:59.000Z

    Pacific Northwest Laboratory (PNL), the US Department of Energy (DOE) Federal Energy Management Program (FEMP), and Potomac Electric Power Company (PEPCO) have been conducting short-term monitoring studies at the Forrestal Building, headquarters of the DOE, since 1990. These studies were an integral part of the Shared Energy Savings (SES) lighting retrofit project completed in 1993. The overall goal of the project was to reduce electricity consumption at the Forrestal Building. One objective of the project was to use the building as a model for other federal SES lighting retrofit efforts. A complete short-term monitoring strategy in support of the SES project was developed. The strategy included baseline measurements of electrical consumption, performance measurements of proposed retrofits, and post-retrofit measurements of electricity consumption. Measurements included power consumption, power harmonics, and lighting levels. The results show a 56% reduction in electrical power consumed for lighting, as well as improved power quality and increased lighting levels.

  14. Distribution and Room Air Mixing Risks to Retrofitted Homes

    SciTech Connect (OSTI)

    Burdick, A.

    2014-12-01T23:59:59.000Z

    ?Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. For a single-story house with ceiling supply air diffusers, ducts are often removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling.

  15. Puget Sound Energy- Multi-Family Efficiency Retrofit Program

    Broader source: Energy.gov [DOE]

    PSE’s Multifamily Program incentives include a range of measures aimed at assisting existing multifamily buildings. There are prescriptive rebates for equipment such as windows, insulation, light...

  16. Effects of an Accelerated Diesel Engine Replacement/Retrofit Program

    E-Print Network [OSTI]

    Millstein, Dev E.; Harley, Robert A

    2009-01-01T23:59:59.000Z

    Heavy-Duty Diesel Truck Emissions. Environ. Sci. Technol. ,reductions in diesel truck emissions are forecast to occurof NO 2 /NO x emissions from diesel trucks equipped with

  17. Indoor Air Quality and Ventilation in Residential Deep Energy Retrofits

    SciTech Connect (OSTI)

    Less, Brennan; Walker, Iain

    2014-06-01T23:59:59.000Z

    Because airtightening is a significant part of Deep Energy Retrofits (DERs), concerns about ventilation and Indoor Air Quality (IAQ) have emerged. To investigate this, ventilation and IAQ were assessed in 17 non-smoking California Deep Energy Retrofit homes. Inspections and surveys were used to assess household activities and ventilation systems. Pollutant sampling performed in 12 homes included six-day passive samples of nitrogen dioxide (NO2), formaldehyde and air exchange rate (AER); time-resolved data loggers were used to measure particle counts. Half of the homes provided continuous mechanical ventilation. Despite these homes being twice as airtight (3.0 and 7.6 ACH50, respectively), their median AER was indistinguishable from naturally vented homes (0.36 versus 0.37 hr--1). Numerous problems were found with ventilation systems; however, pollutant levels did not reach levels of concern in most homes. Ambient NO2 standards were exceeded in some gas cooking homes that used legacy ranges with standing pilots, and in Passive House-style homes without range hoods exhausted to outside. Cooking exhaust systems were installed and used inconsistently. The majority of homes reported using low-emitting materials, and formaldehyde levels were approximately half those in conventional new CA homes (19.7 versus 36 ?g/m3), with emissions rates nearly 40percent less (12.3 versus 20.6 ?g/m2/hr.). Presence of air filtration systems led to lower indoor particle number concentrations (PN>0.5: 8.80E+06 PN/m3 versus 2.99E+06; PN>2.5: 5.46E+0.5 PN/m3 versus 2.59E+05). The results indicate that DERs can provide adequate ventilation and IAQ, and that DERs should prioritize source control, particle filtration and well-designed local exhaust systems, while still providing adequate continuous ventilation.

  18. Stand-Off Furring in Deep Energy Retrofits, Syracuse, New York (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-05-01T23:59:59.000Z

    IBACOS, in collaboration with GreenHomes America, was contracted by the New York State Energy Research and Development Authority to research exterior wall insulation solutions. This research investigated cost-effective deep energy retrofit (DER) solutions for improving the building shell exterior while achieving a cost-reduction goal, including reduced labor costs to reach a 50/50 split between material and labor. The strategies included exterior wall insulation plus energy upgrades as needed in the attic, mechanical and ventilation systems, and basement band joist, walls, and floors. The work can be integrated with other home improvements such as siding or window replacement. This strategy minimizes physical connections to existing wall studs, encapsulates existing siding materials (including lead paint) with spray foam, and creates a vented rain screen assembly to promote drying. GreenHomes America applied construction details created by IBACOS to a test home. 2x4 framing members were attached to the wall at band joists and top plates using 'L' clips, with spray foam insulating the wall after framing was installed. Windows were installed simultaneously with the framing, including extension jambs. The use of clips in specific areas provided the best strength potential, and 'picture framing' the spray foam held the 2x4s in place. Short-term testing was performed at this house, with monitoring equipment installed for long-term testing. Testing measurements will be provided in a later report, as well as utility impact (before and after), costs (labor and materials), construction time, standard specifications, and analysis for the exterior wall insulation strategy.

  19. Evaluation of a Multifamily Retrofit in Climate Zone 5, Boulder, Colorado (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-11-01T23:59:59.000Z

    In 2009, a 37-unit apartment complex located in Boulder, Colorado, underwent an energy retrofit to comply with Boulder SmartRegs Ordinance, a mandate that requires all rental properties to meet certain energy efficiency standards by 2018. The Consortium of Advanced Residential Buildings (CARB), a U.S. Department of Energy Building America team, worked with city planners and building owners to evaluate this program and recently completed a case study evaluating the effectiveness of a collection of retrofit measures.

  20. Multifamily Retrofit Project Manager Job/Task Analysis and Report: September 2013

    SciTech Connect (OSTI)

    Owens, C. M.

    2013-09-01T23:59:59.000Z

    The development of job/task analyses (JTAs) is one of three components of the Guidelines for Home Energy Professionals project and will allow industry to develop training resources, quality assurance protocols, accredited training programs, and professional certifications. The Multifamily Retrofit Project Manager JTA identifies and catalogs all of the tasks performed by multifamily retrofit project managers, as well as the knowledge, skills, and abilities (KSAs) needed to perform the identified tasks.

  1. Estimation of Energy Baseline by Simulation for On-going Commissioning and Energy Saving Retrofit

    E-Print Network [OSTI]

    Miyata, M.; Yoshida, H.; Asada, M.; Iwata, T.; Tanabe, Y.; Yanagisawa, T.

    2006-01-01T23:59:59.000Z

    is about 3% more accurate than the model of Level 1 and 2. 1. INTRODUCTION It is important to propose an objective and rational method to evaluate energy savings caused by the implementation of Commissioning or the retrofit conducted by ESCO (Energy... be calibrated using measured data in order to make them accurate enough. Because the accuracy calibration needs detailed operational data in general and it seems difficult to obtain such data before the implementation of commissioning or ESCO retrofit...

  2. Calculating Energy and Demand Retrofit Savings for Victoria High School: Interim Report

    E-Print Network [OSTI]

    Liu, Y.; Reddy, T. A.; Katipamula, S.; Claridge, D. E.

    1992-01-01T23:59:59.000Z

    ESL-TR-92/12-03 Calculating Energy and Demand Retrofit Savings For Victoria High School Yue Liu, T. Agami Reddy, S. Katipamula and David E. Claridge. Interim Report Energy Systems Laboratory Texas A&M University College Station, TX 77843 December... 1992 Calculating Energy and Demand Retrofit Savings For Victoria High School Yue Liu, T. Agami Reddy, S. Katipamula and David E. Claridge. Interim Report Energy Systems Laboratory Texas A&M University College Station, TX 77843 December 1992 Abstract...

  3. Decision process for the retrofit of municipal buildings with solar energy systems: a technical guide

    SciTech Connect (OSTI)

    Licciardello, Michael R.; Wood, Brian; Dozier, Warner; Braly, Mark; Yates, Alan

    1980-11-01T23:59:59.000Z

    As a background for solar applications, the following topics are covered: solar systems and components for retrofit installations; cost, performance, and quality considerations; and financing alternatives for local government. The retrofit decision process is discussed as follows: pre-screening of buildings, building data requirements, the energy conservation audit, solar system sizing and economics, comparison of alternatives, and implementation. Sample studies are presented for the West Valley Animal Shelter and the Hollywood Police Station. (MHR)

  4. Early Equipment Management

    E-Print Network [OSTI]

    Schlie, Michelle

    2007-05-18T23:59:59.000Z

    the quality, flexibility, reliability, safety, and life-time cost of equipment. This paper will give an introduction to the basics of TPM, discuss the major parts of EEM, and evaluate the lessons learned from the team’s first effort to execute the structured...

  5. Emergency Facilities and Equipment

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1997-08-21T23:59:59.000Z

    This volume clarifies requirements of DOE O 151.1 to ensure that emergency facilities and equipment are considered as part of emergency management program and that activities conducted at these emergency facilities are fully integrated. Canceled by DOE G 151.1-4.

  6. Characterization of Naturally Occurring Radioactive Material (NORM) in Oil and Gas Industry Equipment and Wastes

    SciTech Connect (OSTI)

    Rood, A.S.; White, G.J.

    1999-10-07T23:59:59.000Z

    This Sampling and Analysis (S and A) Plan was developed for the NORM Characterization Program, and describes the information to be gained through the program, how the required information is to be collected, and the anticipated form and content of the final data. The S and A Plan provides detailed procedures describing the work to be performed, how and why the work will be performed, and who will be responsible for conducting the various aspects of the work. The S and A Plan has been prepared with input from all parties involved with the program. Where appropriate, portions of the procedures described in the S and A Plan will be field tested by personnel of the Idaho National Engineering Laboratory (INEL) and the Grand Junction Project Office (GJPO), as well as representatives of the cosponsor organizations prior to their use in the field.

  7. Group Home Energy Efficiency Retrofit for 30% Energy Savings: Washington, D.C. (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-11-01T23:59:59.000Z

    Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes - such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost-effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study's results will be used to identify cost effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

  8. Case study field evaluation of a systems approach to retrofitting a residential HVAC system

    SciTech Connect (OSTI)

    Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

    2003-09-01T23:59:59.000Z

    This case study focusing on a residence in northern California was undertaken as a demonstration of the potential of a systems approach to HVAC retrofits. The systems approach means that other retrofits that can affect the HVAC system are also considered. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC system can be used. Secondly, we wanted to examine the practical issues and interactions with contractors and code officials required to accomplish the systems approach because it represents a departure from current practice. We identified problems in the processes of communication and installation of the retrofit that led to compromises in the final energy efficiency of the HVAC system. These issues must be overcome in order for HVAC retrofits to deliver the increased performance that they promise. The experience gained in this case study was used to optimize best practices guidelines for contractors (Walker 2003) that include building diagnostics and checklists as tools to assist in ensuring the energy efficiency of ''house as a system'' HVAC retrofits. The best practices guidelines proved to be an excellent tool for evaluating the eight existing homes in this study, and we received positive feedback from many potential users who reviewed and used them. In addition, we were able to substantially improve the energy efficiency of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner, an economizer and by reducing duct leakage.

  9. Improvements and Applications of the Methodology for Potential Energy Savings Estimation from Retro-commissioning/Retrofit Measures 

    E-Print Network [OSTI]

    Liu, Jingjing

    2010-03-24T23:59:59.000Z

    This thesis has improved Baltazar's methodology for potential energy savings estimation from retro-commissioning/retrofits measures. Important improvements and discussions are made on optimization parameters, limits on ...

  10. Building America Case Study: Performance of a Hot-Dry Climate Whole House Retrofit, Stockton, California (Fact Sheet)

    SciTech Connect (OSTI)

    ARBI

    2014-09-01T23:59:59.000Z

    The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.

  11. A methdology for baselining the energy use at large campus utility plants for the purpose of measuring energy savings from energy conservation retrofits 

    E-Print Network [OSTI]

    Beasley, Rodney Craig

    1999-01-01T23:59:59.000Z

    The development of the energy services industry and the implementation of energy savings retrofits by energy services companies has increased the focus on the performance of energy saving retrofits. Energy savings measurement, ...

  12. Equipment | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist. Category UC-l 1, 13 DE@Energy Innovation EquipmentHydrogen

  13. Equipment | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist. Category UC-l 1, 13 DE@Energy Innovation EquipmentHydrogenPhilips

  14. UNIRIB: Equipment Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of ScienceandMesa del SolStrengthening aTurbulence may bedieselsummer gasoline price0 - 194Equipment

  15. Maersk Line Equipment guide

    National Nuclear Security Administration (NNSA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilA Approved:AdministrationAnalysisDarby/%2AOU1a ComplexMaersk Line Equipment

  16. Logging Equipment and Loren Kellogg

    E-Print Network [OSTI]

    and the control is passed on Automatic inhaul starts and the control is transferred again Photo Credit: KollerLogging Equipment and Systems Loren Kellogg Forest Engineering Resources and Management Oregon Equipment and Systems Presentation Outline · Overview of equipment and systems for thinning · Costs

  17. Carbon capture retrofits and the cost of regulatory uncertainty

    SciTech Connect (OSTI)

    Reinelt, P.S.; Keith, D.W. [SUNY College of Fredonia, Fredonia, NY (United States). Dept. of Economics

    2007-07-01T23:59:59.000Z

    Power generation firms confront impending replacement of an aging coal-fired fleet in a business environment characterized by volatile natural gas prices and uncertain carbon regulation. We develop a stochastic dynamic programming model of firm investment decisions that minimizes the expected present value of future power generation costs under uncertain natural gas and carbon prices. We explore the implications of regulatory uncertainty on generation technology choice and the optimal timing of investment, and assess the implications of these choices for regulators. We find that interaction of regulatory uncertainty with irreversible investment always raises the social cost of carbon abatement. Further, the social cost of regulatory uncertainty is strongly dependent on the relative competitiveness of IGCC plants, for which the cost of later carbon capture retrofits is comparatively small, and on the firm's ability to use investments in natural gas generation as a transitional strategy to manage carbon regulation uncertainty. Without highly competitive IGCC or low gas prices, regulatory uncertainty can increase the expected social cost of reducing emissions by 40 to 60%.

  18. Construction and startup experience for Milliken FGD Retrofit Project

    SciTech Connect (OSTI)

    Harvilla, J.; Mahlmeister, M. [New York State Electric and Gas Corp., Binghamton, NY (United States); Buchanan, T.; Jackson, C. [Parsons Power Group, Inc., Reading, PA (United States); Watts, J. [USDOE, Pittsburgh Energy Technology Center, PA (United States)

    1996-12-01T23:59:59.000Z

    Under Round 4 of the U.S. Department of Energy`s Clean Coal Technology program, New York State Electric & Gas Corp. (NYSEG), in partnership with Saarbereg-Stebbins Engineering and Manufacturing Company, has retrofitted a formic acid enhanced forced oxidation wet limestone scrubber on Units 1 & 2 at the Milliken Steam Electric Station. Units 1 & 2 are 1950`s vintage Combustion Engineering tangentially fired pulverized coal units which are rated at nominal 150 MW each and operate in balanced draft mode. The FGD system for Unit 2 was placed into operation in January 1995 and the Unit 1 system in June, 1995. The project incorporates several unique aspects including low pH operation, a ceramic tile-lined cocurrent/countercurrent, split module absorber, a wet stack supported on the roof of the FGD building, and closed loop, zero liquid discharge operation producing commercial grade gypsum, and calcium chloride brine. The project objectives include 98% SO{sub 2} removal efficiency while burning high sulfur coal, the production of marketable byproducts to minimize solid waste disposal, zero wastewater discharge and space-saving design. The paper provides a brief overview of the project design, discusses construction and startup issues and presents early operating results. Process capital cost and economics of this design, procure and construct approach are reviewed relative to competing technologies.

  19. Energy Impacts of Energy and Indoor Environmental Quality Retrofits of Apartments in California

    SciTech Connect (OSTI)

    Fisk, William J.; Norris, Federico; Singer, Brett C.

    2013-11-01T23:59:59.000Z

    Monthly gas and electricity use data from a set of 13 study apartments and 20 control apartments from three apartment buildings (B1 B3) in California were analyzed. The study apartments were retrofit with simultaneous energy savings and indoor environmental quality (IEQ) improvements as the goal. The control apartments were not retrofit. Pre-retrofit modeling indicated annual energy savings of 21percent, 17percent, and 27percent for the study apartments in B1-B3, respectively. Based on a comparison of changes in energy use of study apartments to energy use changes of control apartments, total measured savings of gas energy plus site electrical energy were 28percent in B1, 5percent in B2, and 3percent in B3. Given the small number of study apartments and the substantial changes in energy use within control apartments, the project yielded no conclusive evidence of energy savings. Apartment energy use increased with number of occupants and with floor area; however, the association with occupancy was most evident. Climate differences did not appear to be the major driver for the variability in energy use among apartments. Changes in occupant behaviors affecting energy use may have overwhelmed and obscured the energy savings in this small number of buildings. Much larger prior studies employing similar retrofits indicate that the retrofits usually do save energy.

  20. Measuring energy-saving retrofits: Experiences from the Texas LoanSTAR program

    SciTech Connect (OSTI)

    Haberl, J.S.; Reddy, T.A.; Claridge, D.E.; Turner, W.D.; O`Neal, D.L.; Heffington, W.M. [Texas A and M Univ., College Station, TX (United States). Energy Systems Lab.] [Texas A and M Univ., College Station, TX (United States). Energy Systems Lab.

    1996-02-01T23:59:59.000Z

    In 1988 the Governor`s Energy Management Center of Texas received approval from the US Department of Energy to establish a $98.6 million state-wide retrofit demonstration revolving loan program to fund energy-conserving retrofits in state, public school, and local government buildings. As part of this program, a first-of-its-kind, statewide Monitoring and Analysis Program (MAP) was established to verify energy and dollar savings of the retrofits, reduce energy costs by identifying operational and maintenance improvements, improve retrofit selection in future rounds of the LoanSTAR program, and initiate a data base of energy use in institutional and commercial buildings located in Texas. This report discusses the LoanSTAR MAP with an emphasis on the process of acquiring and analyzing data to measure savings from energy conservation retrofits when budgets are a constraint. This report includes a discussion of the program structure, basic measurement techniques, data archiving and handling, data reporting and analysis, and includes selected examples from LoanSTAR agencies. A summary of the program results for the first two years of monitoring is also included.

  1. Cold Climate and Retrofit Applications for Air-to-Air Heat Pumps

    SciTech Connect (OSTI)

    Baxter, Van D [ORNL

    2015-01-01T23:59:59.000Z

    Air source heat pumps (ASHP) including air-to-air ASHPs are easily applied to buildings almost anywhere for new construction as well as retrofits or renovations. They are widespread in milder climate regions but their use in cold regions is hampered due to low heating efficiency and capacity at cold outdoor temperatures. Retrofitting air-to-air ASHPs to existing buildings is relatively easy if the building already has an air distribution system. For buildings without such systems alternative approaches are necessary. Examples are ductless, minisplit heat pumps or central heat pumps coupled to small diameter, high velocity (SDHV) air distribution systems. This article presents two subjects: 1) a summary of R&D investigations aimed at improving the cold weather performance of ASHPs, and 2) a brief discussion of building retrofit options using air-to-air ASHP systems.

  2. Retrofit Audits and Cost Estimates: A Look at Quality and Consistency

    SciTech Connect (OSTI)

    Eisenberg, L.; Shapiro, C.; Fleischer, W.

    2012-10-01T23:59:59.000Z

    Retrofit NYC Block by Block is an outreach program targeting owners of one- to four-family homes, the most common building type in New York City, with more than 600,000 structures citywide. Administered by the Pratt Center for Community Development and implemented by four nonprofit, community based organizations, Block by Block connects residents, businesses, and religious and civic organizations in predominantly low- and moderate-income neighborhoods with one or more of a half-dozen public and private financial incentive programs that facilitate energy-efficiency retrofits. This research project sought to evaluate the approach, effectiveness, and the energy use reductions accomplished by the Retrofit NYC: Block by Block program.

  3. Diesel plant retrofitting options to enhance decentralized electricity supply in Indonesia

    SciTech Connect (OSTI)

    Baring-Gould, E.I.; Barley, C.D.; Drouilhet, S. [and others] [and others

    1997-09-01T23:59:59.000Z

    Over the last 20 years, the government of Indonesia has undertaken an extensive program to provide electricity to the population of that country. The electrification of rural areas has been partially achieved through the use of isolated diesel systems, which account for about 20% of the country`s generated electricity. Due to many factors related to inefficient power production with diesels, the National Renewable Energy Laboratory, in conjunction with PLN, the Indonesian national utility, Community Power Corporation, and Idaho Power Company, analyzed options for retrofitting existing diesel power systems. This study considered the use of different combinations of advanced diesel control, the addition of wind generators, photovoltaics and batteries to reduce the systems of overall cost and fuel consumption. This analysis resulted in a general methodology for retrofitting diesel power systems. This paper discusses five different retrofitting options to improve the performance of diesel power systems. The systems considered in the Indonesian analysis are cited as examples for the options discussed.

  4. Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits

    SciTech Connect (OSTI)

    Dentz, J.; Podorson, D.

    2014-01-01T23:59:59.000Z

    Exterior insulation and finish systems (EIFS) are proprietary synthetic formulations that are applied to the exterior walls of buildings to serve as insulation and exterior cladding. The insulation thickness can vary from less than one inch to a foot or more. In this project the applicability of EIFS for residential deep energy retrofits was investigated through modeling and a case study home. The home was retrofitted using a site-applied four-inch-thick EIFS. Site-specific details were developed as required for the residential retrofit application. Site work and the costs of the EIFS system were documented. The demonstration home was modeled using Building Energy Optimization energy and cost analysis software to explore cost effectiveness of various EIFS insulation thicknesses in two climate locations.

  5. Retrofit of Soederberg smelter at Alusaf Bayside plant. Part 1: Conceptual design and engineering

    SciTech Connect (OSTI)

    Vogelsang, D.; Droste, C.; Segatz, M.; Eick, I. [VAW Aluminium-Technologie GmbH, Bonn (Germany)

    1996-10-01T23:59:59.000Z

    A main objective of the Bayside Smelter modernization at Alusaf Pty. is the retrofit of the Soederberg pots operating at 120 kA to prebake cells with a current load of 165 kA. The complete design and engineering of this modernization project was done by VAW. Based on computer simulations a tailor-made concept for the retrofit project was developed. A pilot plant trial was conducted successfully in 1994. This paper presents the retrofit concept with details of the magneto-hydrodynamic and thermo-electric calculations. Plant measurements demonstrate the good agreement with computer simulations. Some highlights of the detailed engineering for the modernized pots elucidate concepts of integrating existing and new hardware.

  6. Short-term measurements for the determination of envelope retrofit performance

    SciTech Connect (OSTI)

    Subbarao, K.; Mort, D.; Burch, J.

    1985-06-01T23:59:59.000Z

    Short-term monitoring for estimating thermal parameters of a building, along with an analytical technique to (1) determine the long-term performance and (2) calculate the parameters from a building description, has many valuable applications, which include energy ratings, diagnostics, and retrofit analysis. In this paper we address issues relating to reducing uncertainties in estimating thermal parameters with emphasis on retrofit applications. In general, it is necessary to impose a known heat flow with a suitable profile to reliably estimate the parameters. This is demonstrated with test cell measurements taken before and after changes were made to the test cell. The eventual goal of this project is to develop a practical methodology to determine long-term retrofit performance from short-term tests.

  7. The evaluation of a 4000-home geothermal heat pump retrofit at Fort Polk, Louisiana: Final Report

    SciTech Connect (OSTI)

    Hughes, P.J.; Shonder, J.A.

    1998-03-01T23:59:59.000Z

    This report documents an independent evaluation of an energy retrofit of 4,003 family housing units at Fort Polk, Louisiana, under an energy savings performance contract (ESPC). Replacement of the heating, cooling, and water heating systems in these housing units with geothermal heat pumps (GHPs) anchored the retrofit; low-flow shower heads and compact fluorescent lighting were also installed, as well as attic insulation where needed. Statistically valid findings indicate that the project will save 25.8 million kWh, or 32.5% of the pre-retrofit whole-community electrical consumption, and 100% of the whole-community natural gas previously used for space conditioning and water heating (260,000 therms) in a typical meteorological year. At the end-use level, the GHPs were found to save about 42% of the pre-retrofit electrical consumption for heating, cooling, and water heating in housing units that were all-electric in the pre-retrofit period. This report also demonstrates an improved method of predicting energy savings. Using an engineering model calibrated to pre-retrofit energy use data collected in the field, the method predicted actual energy savings on one of the electric feeders at Fort Polk with a very high degree of accuracy. The accuracy of this model was in turn dependent on data-calibrated models of the geothermal heat pump and ground heat exchanger that are described in this report. In addition this report documents the status of vertical borehole ground heat exchanger (BHEx) design methods at the time this project was designed, and demonstrates methods of using data collected from operating GHP systems to benchmark BHEx design methods against a detailed engineering model calibrated to date. The authors also discuss the ESPC`s structure and implementation and how the experience gained here can contribute to the success of future ESPCs.

  8. Electrical Equipment Inventory and Inspection Information

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Electrical Equipment Inventory and Inspection Information APS Non-NRTL Electrical Equipment Inventory Spreadsheet ANL Recognized Reputable Electrical Equipment Manufacturer List as...

  9. Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)

    SciTech Connect (OSTI)

    Not Available

    2013-02-01T23:59:59.000Z

    The U.S. Department of Energy developed the K-12 Advanced Energy Retrofit Guide to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. We emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluation of the most promising retrofit measure for each building type. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings.

  10. Engine technology advances show potential in labs: Part 1. [Retrofitting engine systems on gas distribution networks

    SciTech Connect (OSTI)

    McCoy, J.J. (Tenneco Gas Co., Houston, TX (United States)); Willson, B. (Colorado State Univ., Fort Collins, CO (United States))

    1994-06-01T23:59:59.000Z

    Cutting fuel consumption and reducing emissions are dominant goals of stationary gas engine operators. Recent technology advances show promise and could result in money-saving retrofit options. Selected new technologies include sensors, actuators--defined as anything controlling the engine: fuel and ignition--and control techniques. An attractive feature of most of these technologies is that they can be retrofitted onto existing engines, allowing the potential for improved performance at a fraction of engine replacement cost. This paper reviews these new technologies and how they perform.

  11. Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance; Grocery Stores (Revised) (Book)

    SciTech Connect (OSTI)

    Hendron, B.

    2013-07-01T23:59:59.000Z

    The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders successfully plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited in these guides. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. Grocery stores were selected as one of the highest priority sectors, because they represent one of the most energy-intensive market segments.

  12. A Path to Successful Energy Retrofits: Early Collaboration through Integrated Project Delivery Teams

    SciTech Connect (OSTI)

    Parrish, Kristen

    2012-10-31T23:59:59.000Z

    This document guides you through a process for the early design phases of retrofit projects to help you mitigate frustrations commonly experienced by building owners and designers. It outlines the value of forming an integrated project delivery team and developing a communication and information-sharing infrastructure that fosters collaboration. This guide does not present a complete process for designing an energy retrofit for a building. Instead, it focuses on the early design phase tasks related to developing and selecting energy efficiency measures (EEMs) that benefit from collaboration, and highlights the resulting advantages.

  13. INL '@work' heavy equipment mechanic

    SciTech Connect (OSTI)

    Christensen, Cad

    2008-01-01T23:59:59.000Z

    INL's Cad Christensen is a heavy equipment mechanic. For more information about INL careers, visit http://www.facebook.com/idahonationallaboratory.

  14. Information technology equipment cooling system

    SciTech Connect (OSTI)

    Schultz, Mark D.

    2014-06-10T23:59:59.000Z

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

  15. INL '@work' heavy equipment mechanic

    ScienceCinema (OSTI)

    Christensen, Cad

    2013-05-28T23:59:59.000Z

    INL's Cad Christensen is a heavy equipment mechanic. For more information about INL careers, visit http://www.facebook.com/idahonationallaboratory.

  16. Cold Climate Foundation Retrofit Energy Savings: The Simulated Energy and Experimental Hygrothermal Performance of Cold Climate Foundation Wall Insulation Retrofit Measures -- Phase I, Energy Simulation

    SciTech Connect (OSTI)

    Goldberg, L. F.; Steigauf, B.

    2013-04-01T23:59:59.000Z

    A split simulation whole building energy/3-dimensional earth contact model (termed the BUFETS/EnergyPlus Model or BEM) capable of modeling the full range of foundation systems found in the target retrofit housing stock has been extensively tested. These foundation systems that include abovegrade foundation walls, diabatic floors or slabs as well as lookout or walkout walls, currently cannot be modeled within BEopt.

  17. Sustainable wall construction and exterior insulation retrofit technology process and structure

    DOE Patents [OSTI]

    Vohra, Arun (Bethesda, MD)

    2000-01-01T23:59:59.000Z

    A low-cost process for exterior wall insulation retrofit, or new wall construction by stacking layers of fabric tube filled with insulating material against a wall and covering them with mesh and stucco provides a durable structure with good insulating value.

  18. Energy Conservation in Multifamily Housing: Review and Recommendations for Retrofit Programs

    E-Print Network [OSTI]

    Diamond, Richard

    Energy Conservation in Multifamily Housing: Review and Recommendations for Retrofit Programs John identified as a particularly challenging area for energy conservation efforts. Much work has been done as a book on multifamily energy conservation. Here we preview key results from that project, with a focus

  19. High Level Optimization Model for the Retrofit Planning of Process Networks

    E-Print Network [OSTI]

    Grossmann, Ignacio E.

    optimization techniques for the redesign of crude distillation columns. And Fraser and Hallale10 proposed synthesis. Abstract The retrofit design of a network of processes over several time periods is addressed subsystems and flowsheets for the design of new processes, or "grassroots" design. Many algorithms

  20. Data and analytics to inform energy retrofit of high performance Tianzhen Hong a,

    E-Print Network [OSTI]

    National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720, USA b Tsinghua University, Beijing 100084, China c Jones Lang Lassale, 100 Waterfront Place, West Sacramento, CA 95605, USA h i g h l i g h t s High, and diagnostics. The case study shows 20% of electricity can be saved by retrofit. a r t i c l e i n f o Article

  1. The Caw Burn SUDS: performance of a settlement pond/wetland SUDS retrofit Kate Heal1*

    E-Print Network [OSTI]

    Heal, Kate

    ) to remediate pollution of the Caw Burn by runoff from the Houston Industrial Estate, Livingston, Scotland-study of a retrofit SUDS constructed in 1996 to remediate pollution in the Caw Burn originating in runoff from runoff from the Houston Industrial Estate, where construction commenced in the 1960s, and two residential

  2. YASIR: A Low-Latency, High-Integrity Security Retrofit for Legacy SCADA Systems (Extended Version)

    E-Print Network [OSTI]

    YASIR: A Low-Latency, High-Integrity Security Retrofit for Legacy SCADA Systems (Extended Version security, and yet incurs minimal end-to-end communication latency. Keywords: SCADA network security, bump links between devices in legacy Supervisory Con- trol And Data Acquisition (SCADA) systems, on which

  3. YASIR: A Low-Latency, High-Integrity Security Retrofit for Legacy SCADA Systems

    E-Print Network [OSTI]

    YASIR: A Low-Latency, High-Integrity Security Retrofit for Legacy SCADA Systems Patrick P. Tsang in Supervisory Control And Data Acquisition (SCADA) systems. Previous BITW solutions fail to provide minimal end-to-end communication latency. A microcontroller prototype of our solution is under development

  4. YASIR: A Low-Latency, High-Integrity Security Retrofit for Legacy SCADA Systems

    E-Print Network [OSTI]

    Smith, Sean W.

    YASIR: A Low-Latency, High-Integrity Security Retrofit for Legacy SCADA Systems Patrick P. Tsang-to-end communication latency. 1 Introduction 1.1 SCADA Systems Supervisory Control And Data Acquisition (SCADA) systems Supervisory Control And Data Acquisition (SCADA) systems, on which the proper operations of critical

  5. Edinburgh Research Explorer Modelling Urban scale Retrofit, Pathways to 2050 Low Carbon

    E-Print Network [OSTI]

    Millar, Andrew J.

    electricity consumption in Wales with power generated from renewable sources by 2025 (WAG, 2009) which would to engage with the modelling process. INTRODUCTION The UK government has set an ambitious target of 80 retrofit design process need to be researched further. The Welsh Government have committed to achieving

  6. FLASTAR: Measured Savings of a Comprehensive Energy Retrofit in a Florida Elementary School

    E-Print Network [OSTI]

    Sherwin, J. R.; Parker, D. S.

    1998-01-01T23:59:59.000Z

    .000 square foot facility was approximately 775,000 kWh (60 kBtu/ft^2) or $55,200 in the base year (1994). During the summer of 1995, replacement of aging chillers resulted in 30% reduction to cooling energy use. The second retrofit was occupancy sensor...

  7. Development of Cost Effective Oxy-Combustion Retrofitting for Coal-Fired Boilers

    SciTech Connect (OSTI)

    Hamid Farzan

    2010-12-31T23:59:59.000Z

    The overall objective of this project is to further develop the oxy-combustion technology for commercial retrofit in existing wall-fired and Cyclone boilers by 2012. To meet this goal, a research project was conducted that included pilot-scale testing and a full-scale engineering and economic analysis.

  8. FRP Retrofit of the Ring-Beam of a Nuclear Reactor Containment Structure

    E-Print Network [OSTI]

    SP·215-18 FRP Retrofit of the Ring-Beam of a Nuclear Reactor Containment Structure by M. Demers. A for the storage of the moderately contaminated nuclear reactor. The enforcement of more rigorous environmental. 1. HISTORY 1.1 Decommissioning of the Reactor The Gentilly-I nuclear power plant, located

  9. Review of Methods for Measuring and Verifying Savings from Energy Conservation Retrofits to Existing Buildings

    E-Print Network [OSTI]

    Haberl, J. S.; Culp, C.

    2003-01-01T23:59:59.000Z

    The Measurement & Verification (M&V) process has evolved in the last 15 years to provide a high confidence approach for determining the resulting savings from a variety of retrofits and energy efficiency enhancements. M&V has a dual role. First...

  10. Advanced Energy Retrofit Guide (AERG): Practical Ways to Improve Energy Performance; Healthcare Facilities (Book)

    SciTech Connect (OSTI)

    Hendron, R.; Leach, M.; Bonnema, E.; Shekhar, D.; Pless, S.

    2013-09-01T23:59:59.000Z

    The Advanced Energy Retrofit Guide for Healthcare Facilities is part of a series of retrofit guides commissioned by the U.S. Department of Energy. By presenting general project planning guidance as well as detailed descriptions and financial payback metrics for the most important and relevant energy efficiency measures (EEMs), the guides provide a practical roadmap for effectively planning and implementing performance improvements in existing buildings. The Advanced Energy Retrofit Guides (AERGs) are intended to address key segments of the U.S. commercial building stock: retail stores, office buildings, K-12 schools, grocery stores, and healthcare facilities. The guides' general project planning considerations are applicable nationwide; the energy and cost savings estimates for recommended EEMs were developed based on energy simulations and cost estimates for an example hospital tailored to five distinct climate regions. These results can be extrapolated to other U.S. climate zones. Analysis is presented for individual EEMs, and for packages of recommended EEMs for two project types: existing building commissioning projects that apply low-cost and no-cost measures, and whole-building retrofits involving more capital-intensive measures.

  11. Byggmeister Test Home: Cold Climate Multifamily Masonry Building Condition Assessment and Retrofit Analysis

    SciTech Connect (OSTI)

    Wytrykowska, H.; Ueno, K.; Van Straaten, R.

    2012-09-01T23:59:59.000Z

    This report describes a retrofit project undertaken by Building Science Corporation and partner Byggmeister on a multifamily brick row house located in Jamaica Plain, MA. This project studied the row house to determine the right combination of energy efficiency measures that are feasible, affordable, and suitable for this type of construction and acceptable to homeowners.

  12. CCLEP Retrofit and Innovative Controls to Achieve 56% Energy Savings for a Luxury Shopping Mall 

    E-Print Network [OSTI]

    Wu, L.; Pang, X.; Liu, M.; Wang, J.; Lewis, T. G.

    2007-01-01T23:59:59.000Z

    single fan dual-duct VAV AHUs, 123 dual-duct pneumatic controller pressure independent terminal boxes, and a central heating and cooling plant. Major retrofit efforts include upgrading from pneumatic to DDC controls for all AHUs, installing main hot deck...

  13. ORNL Roof and Attic System Shows Efficient Retrofit By Zaher Karp Reuters, July 27, 2009

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    ORNL Roof and Attic System Shows Efficient Retrofit Option By Zaher Karp ­ Reuters, July 27, 2009 A new roof and attic system developed at the Oak Ridge National Laboratory Building Technology Center. Texas-based Billy Ellis Roofing funds the research through the Building Technology Center

  14. Retrofit precipitators mounted on $28-million deck structure constructed over highway. [Ohio Edison Co. , Sammis station

    SciTech Connect (OSTI)

    Kudich, R.L.; Kirchner, P.N.

    1983-04-01T23:59:59.000Z

    Space problems resulted in a 900-foot concrete deck to hold retrofitted precipitators that collect particulates from the Ohio Edison's largest power station. Because the deck spans a state highway, a tight construction schedule was met using a bonus/penalty agreement. Design considerations included an open construction and riverbank work. 5 figures. (DCK)

  15. Starting a local conservation and passive solar retrofit program: an energy planning sourcebook

    SciTech Connect (OSTI)

    Barber, V; Mathews, R

    1982-02-01T23:59:59.000Z

    A city planner or a neighborhood activist may wish to initiate a local conservation and passive solar retrofit program but may not have previous experience in doing so. This sourcebook is designed to assist interested individuals with their energy planning efforts, from determining retrofit potential, to financing and implementing the program. An approach or methodology is provided which can be applied to determine retrofit potential in single-family residences, mobile homes, multifamily residences, and nonresidential buildings. Case studies in Albuquerque, New Mexico, are given as examples. Guidelines are provided for evaluating the economic benefits of a retrofit program through benefit-cost analysis and economic base studies at the city and neighborhood levels. Also included are approaches to community outreach, detailing how to get started, how to gain local support, and examples of successful programs throughout the US. The need for financing, the development of a local strategy, public and private financing techniques, and community energy service organizations are examined. In addition to the Albuquerque case studies, a brief technology characterization, heat-loss calculations, economic tools, and a list of resources are appended.

  16. COLD STORAGE DESIGN REFRIGERATION EQUIPMENT

    E-Print Network [OSTI]

    COLD STORAGE DESIGN AND REFRIGERATION EQUIPMENT REFRIGERATION OF FISH - PART 1 \\ "..\\- ,,, T I Fishery Leaflet 427 Washington 25, D. C. June 1956 REFRIGERATION OF FISH - PART em; COlD STORAGE DESIGN AND REFRIGERATION EQUIPMENT By Charles Butler (Section 1), Joseph W. Slavin (Sections 1, 2, and 3), Max Patashnik

  17. Actual and Estimated Energy Savings Comparison for Deep Energy Retrofits in the Pacific Northwest

    SciTech Connect (OSTI)

    Blanchard, Jeremy; Widder, Sarah H.; Giever, Elisabeth L.; Baechler, Michael C.

    2012-10-01T23:59:59.000Z

    Seven homes from the Pacific Northwest were selected to evaluate the differences between estimated and actual energy savings achieved from deep energy retrofits. The energy savings resulting from these retrofits were estimated, using energy modeling software, to save at least 30% on a whole-house basis. The modeled pre-retrofit energy use was trued against monthly utility bills. After the retrofits were completed, each of the homes was extensively monitored, with the exception of one home which was monitored pre-retrofit. This work is being conducted by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. This work found many discrepancies between actual and estimated energy savings and identified the potential causes for the discrepancies. The differences between actual energy use and modeled energy use also suggest improvements to improve model accuracy. The difference between monthly whole-house actual and estimated energy savings ranged from 75% more energy saved than predicted by the model to 16% less energy saved for all the monitored homes. Similarly, the annual energy savings difference was between 36% and -14%, which was estimated based on existing monitored savings because an entire year of data is not available. Thus, on average, for all six monitored homes the actual energy use is consistently less than estimates, indicating home owners are saving more energy than estimated. The average estimated savings for the eight month monitoring period is 43%, compared to an estimated savings average of 31%. Though this average difference is only 12%, the range of inaccuracies found for specific end-uses is far greater and are the values used to directly estimate energy savings from specific retrofits. Specifically, the monthly post-retrofit energy use differences for specific end-uses (i.e., heating, cooling, hot water, appliances, etc.) ranged from 131% under-predicted to 77% over-predicted by the model with respect to monitored energy use. Many of the discrepancies were associated with occupant behavior which influences energy use, dramatically in some cases, actual versus modeled weather differences, modeling input limitations, and complex homes that are difficult to model. The discrepancy between actual and estimated energy use indicates a need for better modeling tools and assumptions. Despite the best efforts of researchers, the estimated energy savings are too inaccurate to determine reliable paybacks for retrofit projects. While the monitored data allows researchers to understand why these differences exist, it is not cost effective to monitor each home with the level of detail presented here. Therefore an appropriate balance between modeling and monitoring must be determined for more widespread application in retrofit programs and the home performance industry. Recommendations to address these deficiencies include: (1) improved tuning process for pre-retrofit energy use, which currently utilized broad-based monthly utility bills; (2) developing simple occupant-based energy models that better address the many different occupant types and their impact on energy use; (3) incorporating actual weather inputs to increase accuracy of the tuning process, which uses utility bills from specific time period; and (4) developing simple, cost-effective monitoring solutions for improved model tuning.

  18. Development of a Web-based Emissions Reduction Calculator for Retrofits to Municipal Water Supply and Waste Water Facilities

    E-Print Network [OSTI]

    Baltazar-Cervantes, J. C.; Liu, Z.; Gilman, D.; Haberl, J. S.; Culp, C.

    2005-01-01T23:59:59.000Z

    -------------------------------------- Ycp = 6.9610 ( 0.4799) LS = 0.0000 ( 0.0000) RS = 0.1864 ( 0.0262) Post-Retrofit ESL-IC-10/05-32 wice by Figure 2, t-03 v-03 alized water use for the city using a 3- nge-point linear model... against average riod temperature for the 2002 pre-retrofit h), and 2003 post retrofit period (right t, thru IMT it is determined the ce of the facility using a 4-parameter Xcp = 55.0408 ( 0...

  19. EECBG Direct Equipment Purchase Air Conditioner Guide Equipment Type

    E-Print Network [OSTI]

    EECBG Direct Equipment Purchase Air Conditioner Guide Equipment Type Size Category (Btu/h) Size.ahridirectory.org/ceedirectory/pages/ac/cee/defaultSearch.aspx 12,000 Btu/h = 1 ton Less than 65,000 Btu/h Air Conditioners, Air Cooled Air Conditioners, Water completed by the California Energy Commission at a rate of 12,000 Btu/h per ton of air conditioning Source

  20. Measured Energy Savings from Retrofits Installed in Low-Income Housing in a Hot and Humid Climate

    E-Print Network [OSTI]

    Parker, D. S.; Sherwin, J. R.; Floyd, D. B.

    1998-01-01T23:59:59.000Z

    conditioner performance and house tightness. These audits revealed numerous problems, but low-evaporator coil air flow was discovered in all homes. The paper describes the retrofit installation, audit data collected and the impact on measured energy...

  1. Phase A: Initial Development of an Advanced Diagnostic Procedure for Air-Side Retrofits in Commercial Buildings

    E-Print Network [OSTI]

    Reddy, T. A.; Kissock, J. K.; Katipamula, S.; Claridge, D. E.

    1994-01-01T23:59:59.000Z

    The objective of this research is to develop a diagnostic approach that involves analyzing monitored whole-building cooling and heating energy use in large commercial buildings in order to determine the effectiveness of air-side energy retrofits...

  2. Predicting the potential for energy efficiency retrofits in single-family homes : an exploration of data targeting mechanisms

    E-Print Network [OSTI]

    Goldstein, Kaitlin Ryan

    2014-01-01T23:59:59.000Z

    Historically, the lack of data on the United States' housing stock has been one of the primary barriers to market penetration of residential energy efficiency retrofits. Without knowledge of the homes and customers to ...

  3. Facing the transition. [Retrofitting vessels for burning coal

    SciTech Connect (OSTI)

    Not Available

    1981-08-01T23:59:59.000Z

    Historically, environmental regulations prohibiting black smoke in port and marine disposal of ashes caused many coal-burning vessels in the Great Lakes shipping industry to convert to oil-burning systems. With a return to coal-burning plants on-board, these problems and others are being addressed. Improvements are being made in stack emission control. The need for monitoring devices is discussed. Mechanisms are described which will help control dust, heat, noise and ash. To reduce the need for excessive stockpiles of various grades of coal, equipment is being designed which will burn a range of coals available in many ports. (JMT)

  4. Commonwealth's Master Equipment Leasing Program

    Broader source: Energy.gov [DOE]

    The [http://www.trs.virginia.gov/debt/MELP%20Guides.aspx Master Equipment Leasing Program] (MELP) ensures that all Commonwealth agencies, authorities and institutions obtain consistent and...

  5. Wind Measurement Equipment: Registration (Nebraska)

    Broader source: Energy.gov [DOE]

    All wind measurement equipment associated with the development or study of wind-powered electric generation, whether owned or leased, shall be registered with the Department of Aeronautics if the...

  6. VEHICLES, MACHINERY AND EQUIPMENT Table Of Contents

    E-Print Network [OSTI]

    US Army Corps of Engineers

    of a license/permit for each piece of equipment, an Operator Equipment Qualification Record (DA Form 348EM 385-1-1 XX Sep 13 i Section 18 VEHICLES, MACHINERY AND EQUIPMENT Table Of Contents Section: Page...................................................................18-16 18.G Machinery And Mechanized Equipment.........................18-16 18.H Drilling Equipment

  7. Occupant-in-Place Energy Efficiency Retrofit in a Group Home for 30% Energy Savings in Climate Zone 4

    SciTech Connect (OSTI)

    Moore, M.

    2013-08-01T23:59:59.000Z

    Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes - such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost-effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study's results will be used to identify cost effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

  8. DC CICC retrofit magnet preliminary design, software development and analysis report

    SciTech Connect (OSTI)

    Myatt, R.L.; Marston, P.G.

    1992-02-10T23:59:59.000Z

    The proposed retrofit coil is made of superconducting Cable-in-Conduit Conductor (CICC). The coils are designed to produce a nominal vertical field of 4.5 tesla within the MHD channel based on a nominal current density of 13.05 MA/m{sup 2}. The coils are supported within a case, or so-called constant tension strap. When the magnet is energized, the electromagnetic J {times} B body forces push the winding pack laterally outward and vertically towards the machine's midplane, thus putting the strap in tension. The end turns add axial tension to the conductor (a condition which is not simulated by this 2-D model of the midlength cross section). A sketch of the magnet system and structure is shown in Fig. 1.0-1. The purpose of this report is to describe the progress made in the design and analysis of the DC CICC retrofit magnet, and to outline the proposed next step.

  9. DC CICC retrofit magnet preliminary design, software development and analysis report. Quarterly progress report

    SciTech Connect (OSTI)

    Myatt, R.L.; Marston, P.G.

    1992-01-01T23:59:59.000Z

    The proposed retrofit coil is made of superconducting Cable-in-Conduit Conductor (CICC). The coils are designed to produce a nominal vertical field of 4.5 tesla within the MHD channel based on a nominal current density of 13.05 MA/m{sup 2}. The coils are supported within a case, or so-called constant tension strap. When the magnet is energized, the electromagnetic J x B body forces push the winding pack laterally outward and vertically towards the machine`s midplane, thus putting the strap in tension. The end turns add axial tension to the conductor (a condition which is not simulated by this 2-D model of the midlength cross section). A sketch of the magnet system and structure is shown in Fig. 1.0--1. The purpose of this report is to describe the progress made in the design and analysis of the DC CICC retrofit magnet.

  10. Byggmeister Test Home: Analysis and Initial Results of Cold Climate Wood-Framed Home Retrofit

    SciTech Connect (OSTI)

    Gates, C.

    2013-01-01T23:59:59.000Z

    BSC seeks to further the energy efficiency market for New England area retrofit projects by supporting projects that are based on solid building science fundamentals and verified implementation. With the high exposure of energy efficiency and retrofit terminology being used in the general media at this time, it is important to have evidence that measures being proposed will in fact benefit the homeowner through a combination of energy savings, improved durability, and occupant comfort. There are several basic areas of research to which the technical report for these test homes can be expected to contribute. These include the combination of measures that is feasible, affordable and acceptable to homeowners as well as expectations versus results. Two Byggmeister multi-family test homes in Massachusetts are examined with the goal of providing case studies that could be applied to other similar New England homes.

  11. Development of a Web-based Emissions Reduction Calculator for Street Light and Traffic Light Retrofits

    E-Print Network [OSTI]

    Liu, Z.; Gilman, D.; Haberl, J. S.; Culp, C.

    2005-01-01T23:59:59.000Z

    , street lights and traffic lights represent one of the largest categories of electricity used by a city. By retrofitting the street lights with energy efficient lamps such as high pressure sodium and metal halide and traffic lights with light-emitting... diode (LED) traffic signals, a city 1 In the 2003 and 2005 Texas State legislative sessions, the emissions reductions legislation in Senate Bill 5 was modified by House bill 3235, and House bill 1365...

  12. Assessing the Energy Savings of Tankless Water Heater Retrofits in Public Housing

    SciTech Connect (OSTI)

    Ries, R.; Walters, R.; Dwiantoro, D.

    2013-01-01T23:59:59.000Z

    This report describes the methodology, analysis, and findings from a case study of a 110 unit retrofit of gas tankless water heaters in a hot/humid climate in Alachua County, Florida. The housing units had their gas-fired tank type water heaters replaced with gas-fired tankless water heaters as part of a federal program that targeted reduced energy use in public housing.

  13. Retrofitting Inefficient Rooftop Air-Conditioning Units Reduces U.S. Navy Energy Use (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-04-01T23:59:59.000Z

    As part of the U.S. Navy's overall energy strategy, the National Renewable Energy Laboratory (NREL) partnered with the Naval Facilities Engineering Command (NAVFAC) to demonstrate market-ready energy efficiency measures, renewable energy generation, and energy systems integration. One such technology - retrofitting rooftop air-conditioning units with an advanced rooftop control system - was identified as a promising source for reducing energy use and costs, and can contribute to increasing energy security.

  14. Summary of Construction Equipment Tests and Activities

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Construction Equipment Tests and Activities Bruce Glagola - Sept 2013 Construction Equipment Tests A series of tests were conducted by the APS Construction Vibration...

  15. Advanced Battery Manufacturing Facilities and Equipment Program...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and Equipment Program Advanced Battery Manufacturing Facilities and Equipment Program AVTA: 2010 Honda Civic HEV with Experimental Ultra Lead Acid Battery Testing Results...

  16. Materials Selection Considerations for Thermal Process Equipment...

    Broader source: Energy.gov (indexed) [DOE]

    Materials Selection Considerations for Thermal Process Equipment: A BestPractices Process Heating Technical Brief Materials Selection Considerations for Thermal Process Equipment:...

  17. Low No sub x /SO sub x burner retrofit for utility cyclone boilers

    SciTech Connect (OSTI)

    Moore, K.; Martin, L.; Smith, J.

    1991-05-01T23:59:59.000Z

    The Low NO{sub x}/SO{sub x} (LNS) Burner Retrofit for Utility Cyclone Boilers program consists of the retrofit and subsequent demonstration of the technology at Southern Illinois Power Cooperative's (SIPC's) 33-MW unit 1 cyclone boiler located near Marion, Illinois. The LNS Burner employs a simple innovative combustion process burning high-sulfur Illinois coal to provide substantial SO{sub 2} and NO{sub x} control within the burner. A complete series of boiler performance and characterization tests, called the baseline tests, was conducted in October 1990 on unit 1 of SIPC's Marion Station. The primary objective of the baseline test was to collect data from the existing plant that could provide a comparison of performance after the LNS Burner retrofit. These data could confirm the LNS Burner's SO{sub x} and NO{sub x} emissions control and any effect on boiler operation. Further, these tests would provide to the project experience with the operating characteristics of the host unit as well as engineering design information to minimize technical uncertainties in the application of the LNS Burner technology.

  18. DEMONSTRATION OF A FULL-SCALE RETROFIT OF THE ADVANCED HYBRID PARTICULATE COLLECTOR TECHNOLOGY

    SciTech Connect (OSTI)

    Tom Hrdlicka; William Swanson

    2005-12-01T23:59:59.000Z

    The Advanced Hybrid Particulate Collector (AHPC), developed in cooperation between W.L. Gore & Associates and the Energy & Environmental Research Center (EERC), is an innovative approach to removing particulates from power plant flue gas. The AHPC combines the elements of a traditional baghouse and electrostatic precipitator (ESP) into one device to achieve increased particulate collection efficiency. As part of the Power Plant Improvement Initiative (PPII), this project was demonstrated under joint sponsorship from the U.S. Department of Energy and Otter Tail Power Company. The EERC is the patent holder for the technology, and W.L. Gore & Associates was the exclusive licensee for this project. The project objective was to demonstrate the improved particulate collection efficiency obtained by a full-scale retrofit of the AHPC to an existing electrostatic precipitator. The full-scale retrofit was installed on an electric power plant burning Powder River Basin (PRB) coal, Otter Tail Power Company's Big Stone Plant, in Big Stone City, South Dakota. The $13.4 million project was installed in October 2002. Project related testing concluded in December 2005. The following Final Technical Report has been prepared for the project entitled ''Demonstration of a Full-Scale Retrofit of the Advanced Hybrid Particulate Collector Technology'' as described in DOE Award No. DE-FC26-02NT41420. The report presents the operation and performance results of the system.

  19. Corrosion indicating equipment UK-1

    SciTech Connect (OSTI)

    Gerasimenko, Y.S.; Abrosimov, V.S.; Rudenko, A.K.; Sorokin, V.I.

    1986-11-01T23:59:59.000Z

    UK-1, developed and introduced into oil industry corrosion-indicating equipment, has been developed on the basis of the principle of measurements of polarization resistance. It is designed for determining the corrosion activity of effluents of oil fields. The technical data and design of the equipment is discussed. The investigations were carried out on 08kp steel in simulation effluents of oil fields in the presence of corrosion inhibitors used in the oil industry at various temperatures (25-50 C) and liquid flow rate.

  20. Characterization of naturally occurring porous media

    E-Print Network [OSTI]

    Riley, Robert Daniel

    1965-01-01T23:59:59.000Z

    characteristics of natural occur- ring porous media, The gR /K dimensionless ratio is related to the minimum water saturation in the reverse manner as is permeability. REFERENCES Wyllie, M. R. J. and M. B. Spangler: Application of Electrical Resistivity...: Resistivity of Brine-Saturated Sands in Relation to Pore Seometry. Cornell, D. snd D. L. Kstz: Flow of Sases through Consolidated Porous Media. Industrial and En ineeri hemietr (October 1953) Vo . 5, p. 21 5. Leverett, N, C. : Capillary Behavior...

  1. Applying Best Practices to Florida Local Government Retrofit Programs

    SciTech Connect (OSTI)

    McIlvaine, J.; Sutherland, K.

    2013-12-01T23:59:59.000Z

    In some communities, local government and non-profit entities have funds to purchase and renovate distressed, foreclosed homes for resale in the affordable housing market. Numerous opportunities to improve whole house energy efficiency are inherent in these comprehensive renovations. BA-PIRC worked together in a multi-year field study making recommendations in individual homes, meanwhile compiling improvement costs, projected energy savings, practical challenges, and labor force factors surrounding common energy-related renovation measures. The field study, Phase 1 of this research, resulted in a set of best practices appropriate to the current labor pool and market conditions in central Florida to achieve projected annual energy savings of 15-30% and higher. This report describes Phase 2 of the work where researchers worked with a local government partner to implement and refine the 'current best practices.' A simulation study was conducted to characterize savings potential under three sets of conditions representing varying replacement needs for energy-related equipment and envelope components. The three scenarios apply readily to the general remodeling industry as for renovation of foreclosed homes for the affordable housing market. Our new local government partner, the City of Melbourne, implemented the best practices in a community-scale renovation program that included ten homes in 2012.

  2. Innovative coke oven gas cleaning system for retrofit applications

    SciTech Connect (OSTI)

    Not Available

    1990-09-10T23:59:59.000Z

    All of the project work since the previous report has been on Phase 2B tasks. Therefore, this quarterly progress report summarizes the period's activities in Engineering, Procurement and Civil Construction. Engineering is 95% complete, but revisions and changes are still being incorporated particularly in the Instrument and Electrical areas. Procurement has only valves 4 in. and above yet to order to complete all major items purchased. The scheduled material curve was based on the original estimate of the job. The projected curve reflects the previous month's estimate. Construction of civil work is proceeding according to schedule in the field. The initial bid packages for the Mechanical General Contractor portion of the work have been reviewed and evaluated. Order placement is scheduled for the end of July. The Electrical package is due back from the bidders on July 6. It requires additional evaluation by BSC and DSO and will not be placed until late August. The cost of the project is ahead of the cost or spending plan because of the accelerated progress in the field and early delivery of equipment. However, there are some concerns that the mechanical and electrical bid packages are higher than planned. Although we plan to determine the causes of the increases, we do not intend to let it effect the progress of the project. 7 figs.

  3. Positive materials identification of existing equipment

    SciTech Connect (OSTI)

    Wolf, H.A. [Exxon Research and Engineering Co., Florham Park, NJ (United States)

    1996-07-01T23:59:59.000Z

    Considerable engineering effort and expertise are expended for materials selection at refining and petrochemical facilities. However, the benefits of this effort are undermined if there is an inadvertent material substitution during construction. Although procedures have always been in place to reduce the chance of such substitutions, it is known that these errors have occurred. Accordingly, over the years the industry has periodically reviewed and improved quality control in this effort. However, many older facilities that did not benefit from today`s procedures are still in operation. As a consequence, some companies have conducted positive material identification (PMI) verification of existing equipment. This process is further complicated by the fact that the most susceptible components are typically insulated and must be located. Once located, accessibility and operating temperatures are complicating issues. This paper describes prioritization issues and hardware tradeoffs for conducting a PMI verification program.

  4. Liquid balance monitoring inside conventional, Retrofit, and bio-reactor landfill cells

    SciTech Connect (OSTI)

    Abichou, Tarek, E-mail: abichou@eng.fsu.edu [Department of Civil and Environmental Engineering, Florida State University, 2525 Pottsdamer Street, Tallahassee, FL 32311 (United States); Barlaz, Morton A. [Department of Civil, Construction, and Environmental Engineering, North Carolina State University, Raleigh, NC 27695 (United States); Green, Roger; Hater, Gary [Waste Management Inc., Cincinnati, OH 45211 (United States)

    2013-10-15T23:59:59.000Z

    Highlights: • The Retrofit, Control, and As-Built cells received 48, 14, and 213 L Mg{sup ?1} (liters of liquids per metric ton of waste). • The leachate collection system yielded 60, 57 and 198 L Mg{sup ?1} from the Retrofit, Control, and As-Built cells. • The head on liner in all cells was below regulatory limits. • Measured moisture content of the waste samples was consistent with that calculated from accumulated liquid by balance. • The in-place saturated hydraulic conductivity of the MSW was calculated to be in the range of 10{sup ?8} to 10{sup ?7} m s{sup ?1}. - Abstract: The Outer Loop landfill bioreactor (OLLB) in Louisville, KY, USA has been the site of a study to evaluate long-term bioreactor performance at a full-scale operational landfill. Three types of landfill units were studied including a conventional landfill (Control cell), a new landfill area that had an air addition and recirculation piping network installed as waste was being placed (As-Built cell), and a conventional landfill that was modified to allow for liquids recirculation (Retrofit cell). During the monitoring period, the Retrofit, Control, and As-Built cells received 48, 14, and 213 L Mg{sup ?1} (liters of liquids per metric ton of waste), respectively. The leachate collection system yielded 60, 57 and 198 L Mg{sup ?1} from the Retrofit, Control, and As-Built cells, respectively. The head on liner in all cells was below regulatory limits. In the Control and As-Built cells, leachate head on liner decreased once waste placement stopped. The measured moisture content of the waste samples was consistent with that calculated from the estimate of accumulated liquid by the liquid balance. Additionally, measurements on excavated solid waste samples revealed large spatial variability in waste moisture content. The degree of saturation in the Control cells decreased from 85% to 75%. The degree of saturation increased from 82% to 83% due to liquids addition in the Retrofit cells and decreased back to 80% once liquid addition stopped. In the As-Built cells, the degree of saturation increased from 87% to 97% during filling activities and then started to decrease soon after filling activities stopped to reach 92% at the end of the monitoring period. The measured leachate generation rates were used to estimate an in-place saturated hydraulic conductivity of the MSW in the range of 10{sup ?8} to 10{sup ?7} m s{sup ?1} which is lower than previous reports. In the Control and Retrofit cells, the net loss in liquids, 43 and 12 L Mg{sup ?1}, respectively, was similar to the measured settlement of 15% and 5–8% strain, respectively (Abichou et al., 2013). The increase in net liquid volume in the As-Built cells indicates that the 37% (average) measured settlement strain in these cells cannot be due to consolidation as the waste mass did not lose any moisture but rather suggests that settlement was attributable to lubrication of waste particle contacts, softening of flexible porous materials, and additional biological degradation.

  5. Equipment

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Facility: Building 382 Rev. 1, 021100 Training: (1) ESH114 LockoutTagout ASD125 APS LOTO ESH371 Electrical Safety - General ESH195 PPE ESH141 Hand and Power Tools (2) ESH707...

  6. Covered Product Category: Imaging Equipment

    Broader source: Energy.gov [DOE]

    FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including imaging equipment, which is covered by the ENERGY STAR® program. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  7. Heating and Cooling Equipment Selection

    SciTech Connect (OSTI)

    Not Available

    2002-01-01T23:59:59.000Z

    This is one of a series of technology fact sheets created to help housing designers and builders adopt a whole-house design approach and energy efficient design practices. The fact sheet helps people choose the correct equipment for heating and cooling to reduce initial costs, increase homeowner comfort, increase operating efficiency, and greatly reduce utility costs.

  8. NCSU Box 7401 Raleigh, NC 27695 (919) 515-3480 Toll Free 1-800-33-NC SUN Passive Solar Retrofit

    E-Print Network [OSTI]

    SOLAR CENTER INFORMATION Passive solar retrofit is the adding of solar features to an existing house you begin a passive solar retrofit, you should make sure that your house is energy) for your house. You may also want to review passive solar principles described in the Solar Center

  9. Used energy-related laboratory equipment grant program for institutions of higher learning. Eligible equipment catalog

    SciTech Connect (OSTI)

    Not Available

    1994-07-01T23:59:59.000Z

    This is a listing of energy related equipment available through the Energy-Related Laboratory Equipment Grant Program which grants used equipment to institutions of higher education for energy-related research. Information included is an overview of the program, how to apply for a grant of equipment, eligibility requirements, types of equipment available, and the costs for the institution.

  10. Cost-Effectiveness of Home Energy Retrofits in Pre-Code Vintage Homes in the United States

    SciTech Connect (OSTI)

    Fairey, P.; Parker, D.

    2012-11-01T23:59:59.000Z

    This analytical study examines the opportunities for cost-effective energy efficiency and renewable energy retrofits in residential archetypes constructed prior to 1980 (Pre-Code) in fourteen U.S. cities. These fourteen cities are representative of each of the International Energy Conservation Code (IECC) climate zones in the contiguous U.S. The analysis is conducted using an in-house version of EnergyGauge USA v.2.8.05 named CostOpt that has been programmed to perform iterative, incremental economic optimization on a large list of residential energy efficiency and renewable energy retrofit measures. The principle objectives of the study are as follows: to determine the opportunities for cost effective source energy reductions in this large cohort of existing residential building stock as a function of local climate and energy costs; and to examine how retrofit financing alternatives impact the source energy reductions that are cost effectively achievable.

  11. Assessment of HYGAS mechanical equipment

    SciTech Connect (OSTI)

    Albrecht, P.R.; Kramberger, F.E.; Recupero, R.M.; Verden, M.L.; Rees, K.

    1980-10-01T23:59:59.000Z

    The HYGAS process, which converts coal to substitute natural gas, is being developed by the Institute of Gas Technology (IGT) using an 80 ton per day pilot plant located in Chicago, Illinois. Plant design started in 1967 and testing began in October 1971. Since then, 18,000 tons of both Eastern and Western coal have been gasified. Assessment of the mechanical equipment was made by Mechanical Technology Incorporated (MTI) in collaboration with a DOE on-site representative and a representative from IGT, the operating contractor. Data for the assessment were obtained by reviewing all available maintenance records, by interviewing key personnel from maintenance and operations, and by observing repairs and maintenance procedures where possible. While operating the plant, a variety of equipment problems were addressed, many of which are generic to HYGAS as well as other coal conversion processes. Some problems were solved completely while others were solved to suit the limited needs of the pilot plant. Accordingly, the emphasis of this study is on the degree of success in dealing with equipment failures, the unresolved problems and the implication to future coal conversion plants.

  12. Strategy Guideline: HVAC Equipment Sizing

    SciTech Connect (OSTI)

    Burdick, A.

    2012-02-01T23:59:59.000Z

    The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

  13. Housing Archetype Analysis for Home Energy-Efficient Retrofit in the Great Lakes Region

    SciTech Connect (OSTI)

    Kim, S. K.; Mrozowski, T.; Harrell-Seyburn, A.; Ehrlich, N.; Hembroff, L.; Bieburn, B.; Mazor, M.; McIntyre, A.; Mutton, C.; Parsons, G.; Syal, M. G.; Wilkinson, R.

    2014-09-01T23:59:59.000Z

    This project report details activities and results of the 'Market Characterization' project undertaken by the Cost Effective Energy Retrofit (CEER) team targeted toward the DOE goal of achieving 30%-50% reduction in existing building energy use. CEER consists of members from the Dow Chemical Company, Michigan State University, Ferris State University and Habitat for Humanity Kent County. The purpose of this market characterization project was to identify housing archetypes which are dominant within Great Lakes region and therefore offer significant potential for energy-efficient retrofit research and implementation due to the substantial number of homes possessing similar characteristics. Understanding the characteristics of housing groups referred to as 'archetypes' by vintage, style, and construction characteristics can allow research teams to focus their retrofit research and develop prescriptive solutions for those structure types which are prevalent and offer high potential uptake within a region or market. Key research activities included; literature review, statistical analysis of national and regional data of the American Housing Survey (AHS) collected by the U.S. Census Bureau, analysis of Michigan specific data, development of a housing taxonomy of architectural styles, case studies of two local markets (i.e., Ann Arbor and Grand Rapids in Michigan) and development of a suggested framework (or process) for characterizing local markets. In order to gain a high level perspective, national and regional data from the U.S. Census Bureau was analyzed using cross tabulations, multiple regression models, and logistic regression to characterize the housing stock and determine dominant house types using 21 variables.

  14. Viscous-Fluid-Spring Damper Retrofit of a Steel Moment Frame Structure

    SciTech Connect (OSTI)

    Hussain, Saif [Managing Principal, Coffman Engineers, Inc., 16133 Ventura Blvd., Suite 1010, Encino, California (United States); Van Benschoten, Paul [Principal, Coffman Engineers, Inc., 16133 Ventura Blvd., Suite 1010, Encino, California (United States); Al Satari, Mohamed; Lin, Silian [Structural Engineer, Coffman Engineers, Inc., 16133 Ventura Blvd., Suite 1010, Encino, California (United States)

    2008-07-08T23:59:59.000Z

    The subject building is a peculiar pre-Northridge steel moment resisting frame building. Upon investigating the existing lateral resisting system, numerous significant deficiencies were identified; inherent lack of redundancy, poor geometry and inadequate stiffness of the lateral resisting system. All of which resulted in an extremely soft 5-story structure with a primary torsional mode of vibration at T{sub 1} = 5.46 s. Significant structural modifications were deemed necessary to meet the 'life-safety' performance objective as outlined in rehabilitation standards such as ASCE 41. Both increased stiffness and damping were required to adequately retrofit the building. Furthermore, adjacent building separation as well as deformation compatibility issues needed to be addressed and resolved. A three-dimensional computer model of the building was created using ETABS mathematically simulating the building's dynamic characteristics in its current condition. Multiple seismic retrofit systems were investigated such as Buckling Restrained Braced Frames (BRBF's). However, based on the performance effectiveness and constructability of the retrofit schemes studied, the Viscous-Fluid-Spring Damper (VFSD) system was proposed as the 'optimum' solution for the building. The VFSD, was chosen because it combines the relatively compact size and minimally invasive constructability with the required properties (an elastomeric spring in parallel with a nonlinear velocity dependent viscous damper). A site-specific response spectrum was developed for the Design Basis Earthquake (DBE, 475 year return period) event, and three pairs of representative earthquake horizontal ground motion time-histories were scaled to match this DBE. The proposed scheme reduced the building maximum inter-story drift ratio from 5.4% to about 1%. Similarly, the maximum roof displacement was reduced by about 70% (23'' to 7'')

  15. Pre-Retrofit Lighting Study at the University of Texas at Arlington, Texas

    E-Print Network [OSTI]

    Houcek, J. K.; Claridge, D. E.; Haberl, J. S.

    1993-01-01T23:59:59.000Z

    in terms of energy efficiency. The most relevant report is a 1991 Electric Power Research Institute (EPRI) publication entitled "Retrofit Lighting Technologies". Table 4 presents a summary of data provided in the EPRI report. Table 4 Lamp Comparison Table... (Based on 2 lamp systems) Notes: ? All lamps at 4100K color temperature ?? No longer manufactured ??? Using T-8 instant-start mode ballast with 0.97 ballast factor. For rapid-start T8 electronic ballast with 0.90 ballast factor, values are 5220 lm,61 W...

  16. An Evaluation of Energy-Saving Retrofits from the Texas LoanSTAR Program

    E-Print Network [OSTI]

    Haberl, J. S.; Claridge, D. E.; Heneghan, T.; Sieggreen, R.; Sims, J.

    1996-01-01T23:59:59.000Z

    for future CV to VAV air-handler retrofits. First, it is important to commission the VAV system once it has been installed and prevent the building operators from raising the static pressure to the point where the system no longer functions as a VAV. Second... 9: Estimated Costs Compared To The 1993 Utility Costs... 38 Figure 10: Site Area 41 Figure 11: Estimated Cost Per Square Foot Of Conditioned Area (VFD To AHU) 43 Figure 12: Estimated Cost Per Square Foot Of Conditioned Area (HVACVAV) 45 Figure 13...

  17. Development of an advanced high efficiency coal combustor for boiler retrofit

    SciTech Connect (OSTI)

    LaFlesh, R.C.; Rini, M.J.; McGowan, J.G.; Beer, J.M.; Toqan, M.A.

    1990-04-01T23:59:59.000Z

    The objective of the program was to develop an advanced coal combustion system for firing beneficiated coal fuels (BCFs) capable of being retrofitted to industrial boilers originally designed for firing natural gas. The High Efficiency Advanced Coal Combustor system is capable of firing microfine coal-water fuel (MCWF), MCWF with alkali sorbent (for SO{sub 2} reduction), and dry microfine coal. Design priorities for the system were that it be simple to operate and offer significant reductions in NO{sub x}, SO{sub x}, and particulate emissions as compared with current coal-fired combustor technology. (VC)

  18. Development of an advanced high efficiency coal combustor for boiler retrofit. Summary report

    SciTech Connect (OSTI)

    LaFlesh, R.C.; Rini, M.J.; McGowan, J.G.; Beer, J.M.; Toqan, M.A.

    1990-04-01T23:59:59.000Z

    The objective of the program was to develop an advanced coal combustion system for firing beneficiated coal fuels (BCFs) capable of being retrofitted to industrial boilers originally designed for firing natural gas. The High Efficiency Advanced Coal Combustor system is capable of firing microfine coal-water fuel (MCWF), MCWF with alkali sorbent (for SO{sub 2} reduction), and dry microfine coal. Design priorities for the system were that it be simple to operate and offer significant reductions in NO{sub x}, SO{sub x}, and particulate emissions as compared with current coal-fired combustor technology. (VC)

  19. Retrofit Program of a Euro 1 andn EUro 2 Urban Bus Fleet in La Rochelle:

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingof EnhancedRestructuringNinthRetrofit ProgramStatus

  20. Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst on a Tier 0,

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingof EnhancedRestructuringNinthRetrofitDepartment

  1. SCR & DPF RETROFITS FOR MOBILE DIESEL ENGINES | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingofRetrofittingFundAofSCE&G-4-E Wholesale

  2. SCRT Technology for Retrofit of Heavy-Duty Diesel Applications | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingofRetrofittingFundAofSCE&G-4-EStandards inof

  3. Critical Question #1: How Do We Retrofit the Tough Buildings? | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"Wave theJuly 30,Crafty Gifts for theof Energy 1: How Do We Retrofit

  4. Introduction to naturally occurring radioactive material

    SciTech Connect (OSTI)

    Egidi, P.

    1997-08-01T23:59:59.000Z

    Naturally occurring radioactive material (NORM) is everywhere; we are exposed to it every day. It is found in our bodies, the food we eat, the places where we live and work, and in products we use. We are also bathed in a sea of natural radiation coming from the sun and deep space. Living systems have adapted to these levels of radiation and radioactivity. But some industrial practices involving natural resources concentrate these radionuclides to a degree that they may pose risk to humans and the environment if they are not controlled. Other activities, such as flying at high altitudes, expose us to elevated levels of NORM. This session will concentrate on diffuse sources of technologically-enhanced (TE) NORM, which are generally large-volume, low-activity waste streams produced by industries such as mineral mining, ore benefication, production of phosphate Fertilizers, water treatment and purification, and oil and gas production. The majority of radionuclides in TENORM are found in the uranium and thorium decay chains. Radium and its subsequent decay products (radon) are the principal radionuclides used in characterizing the redistribution of TENORM in the environment by human activity. We will briefly review other radionuclides occurring in nature (potassium and rubidium) that contribute primarily to background doses. TENORM is found in many waste streams; for example, scrap metal, sludges, slags, fluids, and is being discovered in industries traditionally not thought of as affected by radionuclide contamination. Not only the forms and volumes, but the levels of radioactivity in TENORM vary. Current discussions about the validity of the linear no dose threshold theory are central to the TENORM issue. TENORM is not regulated by the Atomic Energy Act or other Federal regulations. Control and regulation of TENORM is not consistent from industry to industry nor from state to state. Proposed regulations are moving from concentration-based standards to dose-based standards. So when is TENORM a problem? Where is it a problem? That depends on when, where, and whom you talk to! We will start by reviewing background radioactivity, then we will proceed to the geology, mobility, and variability of these radionuclides. We will then review some of the industrial sectors affected by TENORM, followed by a brief discussion on regulatory aspects of the issue.

  5. How low-energy fusion can occur

    E-Print Network [OSTI]

    B. Ivlev

    2012-12-04T23:59:59.000Z

    Fusion of two deuterons of room temperature energy is discussed. The nuclei are in vacuum with no connection to any external source (electric or magnetic field, illumination, surrounding matter, traps, etc.) which may accelerate them. The energy of two nuclei is conserved and remains small during the motion through the Coulomb barrier. The penetration through this barrier, which is the main obstacle for low-energy fusion, strongly depends on a form of the incident flux on the Coulomb center at large distances from it. In contrast to the usual scattering, the incident wave is not a single plane wave but the certain superposition of plane waves of the same energy and various directions, for example, a convergent conical wave. The wave function close to the Coulomb center is determined by a cusp caustic which is probed by de Broglie waves. The particle flux gets away from the cusp and moves to the Coulomb center providing a not small probability of fusion (cusp driven tunneling). Getting away from a caustic cusp also occurs in optics and acoustics.

  6. Continuous Controls: Lighting Energy Management for Retrofit and New Construction Projects

    E-Print Network [OSTI]

    Schuett, R.

    1985-01-01T23:59:59.000Z

    The rising interest of specifiers and end-users in Lighting Energy Management (LEM) control equipment has led to an increased need for further education in the selection, capabilities and applications of such equipment. This paper addresses...

  7. Abatement of Air Pollution: Air Pollution Control Equipment and Monitoring Equipment Operation (Connecticut)

    Broader source: Energy.gov [DOE]

    These regulations contain instructions for the operation and monitoring of air pollution control equipment, as well as comments on procedures in the event of equipment breakdown, failure, and...

  8. Machinery and Equipment Expensing Deduction (Kansas)

    Broader source: Energy.gov [DOE]

    Machinery and Equipment Expensing Deduction allows Kansas taxpayers to claim an expense deduction for business machinery and equipment, placed in service in Kansas during the tax year. The one-time...

  9. Asset Management Equipment Disposal Form -Refrigerant Recovery

    E-Print Network [OSTI]

    Sin, Peter

    Asset Management Equipment Disposal Form - Refrigerant Recovery Safe Disposal Requirements Under refrigeration, cold storage warehouse refrigeration, chillers, and industrial process refrigeration) has to have the refrigerant recovered in accordance with EPA's requirements for servicing. However, equipment that typically

  10. Operations and Maintenance for Major Equipment Types

    Broader source: Energy.gov [DOE]

    Equipment lies at the heart of all operations and maintenance (O&M) activities. This equipment varies greatly across the Federal sector in age, size, type, model, condition, etc.

  11. Equipment Listing | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist. Category UC-l 1, 13 DE@Energy Innovation Equipment Listing

  12. Equipment Loans | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist. Category UC-l 1, 13 DE@Energy Innovation Equipment ListingLoans

  13. Equipment Pool | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist. Category UC-l 1, 13 DE@Energy Innovation Equipment

  14. Equipment Certification | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model,DOEHazel Crest,EnergySerranopolisEnviroMissionEquipment

  15. MPC Equipment | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated Codes |IsLove Your Home and It'll Love YouTokamak |MPC Equipment The MPC

  16. Proceedings: Tenth EPRI Substation Equipment Diagnostics Conference

    SciTech Connect (OSTI)

    None

    2002-06-01T23:59:59.000Z

    Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The tenth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

  17. Proceedings: Substation Equipment Diagnostics Conference IX

    SciTech Connect (OSTI)

    None

    2001-09-01T23:59:59.000Z

    Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The ninth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

  18. Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)

    SciTech Connect (OSTI)

    Not Available

    2013-12-01T23:59:59.000Z

    The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit energy efficiency measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings nationwide. U.S. K-12 school districts spend more than $8 billion each year on energy - more than they spend on computers and textbooks combined. Most occupy older buildings that often have poor operational performance - more than 30% of schools were built before 1960. The average age of a school is about 42 years - which is nearly the expected serviceable lifespan of the building. K-12 schools offer unique opportunities for deep, cost-effective energy efficiency improvements, and this guide provides convenient and practical guidance for exploiting these opportunities in the context of public, private, and parochial schools.

  19. Predicted Versus Actual Savings for a Low-Rise Multifamily Retrofit in Boulder, Colorado

    SciTech Connect (OSTI)

    Arena, L.; Williamson, J.

    2013-11-01T23:59:59.000Z

    To determine the most cost-effective methods of improving buildings, accurate analysis and prediction of the energy use of existing buildings is essential. However, multiple studies confirm that analysis methods tend to over-predict energy use in poorly insulated, leaky homes and thus, the savings associated with improving those homes. In NREL's report titled 'Assessing and Improving the Accuracy of Energy Analysis of Residential Buildings,' researchers propose a method for improving the accuracy of residential energy analysis methods. A key step in this process involves the comparisons of predicted versus metered energy use and savings. In support of this research need, CARB evaluated the retrofit of a multifamily building in Boulder, CO. The updated property is a 37 unit, 2 story apartment complex built in 1950, which underwent renovations in early 2009 to bring it into compliance with Boulder, CO's SmartRegs ordinance. Goals of the study were to: 1) evaluate predicted versus actual savings due to the improvements, 2) identify areas where the modeling assumptions may need to be changed, and 3) determine common changes made by renters that would negatively impact energy savings. In this study, CARB seeks to improve the accuracy of modeling software while assessing retrofit measures to specifically determine which are most effective for large multifamily complexes in the cold climate region. Other issues that were investigated include the effects of improving building efficiency on tenant comfort, the impact on tenant turnover rates, and the potential market barriers for this type of community scale project.

  20. DC CICC retrofit magnet preliminary design, software development and analysis report. Quarterly progress report, January 1992

    SciTech Connect (OSTI)

    Myatt, R.L.; Marston, P.G.

    1992-02-10T23:59:59.000Z

    The proposed retrofit coil is made of superconducting Cable-in-Conduit Conductor (CICC). The coils are designed to produce a nominal vertical field of 4.5 tesla within the MHD channel based on a nominal current density of 13.05 MA/m{sup 2}. The coils are supported within a case, or so-called constant tension strap. When the magnet is energized, the electromagnetic J {times} B body forces push the winding pack laterally outward and vertically towards the machine`s midplane, thus putting the strap in tension. The end turns add axial tension to the conductor (a condition which is not simulated by this 2-D model of the midlength cross section). A sketch of the magnet system and structure is shown in Fig. 1.0-1. The purpose of this report is to describe the progress made in the design and analysis of the DC CICC retrofit magnet, and to outline the proposed next step.

  1. Innovative coke oven gas cleaning system for retrofit applications. Volume 1, Public design report

    SciTech Connect (OSTI)

    Not Available

    1994-05-24T23:59:59.000Z

    This Public Design Report provides, in a single document, available nonproprietary design -information for the ``Innovative Coke Oven Gas Cleaning System for Retrofit Applications`` Demonstration Project at Bethlehem Steel Corporation`s Sparrows Point, Maryland coke oven by-product facilities. This project demonstrates, for the first time in the United States, the feasibility of integrating four commercially available technologies (processes) for cleaning coke oven gas. The four technologies are: Secondary Gas Cooling, Hydrogen Sulfide and Ammonia Removal, Hydrogen Sulfide and Ammonia Recovery, and Ammonia Destruction and Sulfur Recovery. In addition to the design aspects, the history of the project and the role of the US Department of,Energy are briefly discussed. Actual plant capital and projected operating costs are also presented. An overview of the integration (retrofit) of the processes into the existing plant is presented and is followed by detailed non-proprietary descriptions of the four technologies and their overall effect on reducing the emissions of ammonia, sulfur, and other pollutants from coke oven gas. Narrative process descriptions, simplified process flow diagrams, input/output stream data, operating conditions, catalyst and chemical requirements, and utility requirements are given for each unit. Plant startup provisions, environmental considerations and control monitoring, and safety considerations are also addressed for each process.

  2. Evaluation of energy savings related to building envelope retrofit techniques and ventilation strategies for low energy cooling in

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    strategies for low energy cooling in offices and commercial sector Laurent Grignon-Massé, Dominique Marchio and automatic controls and the use of adequate ventilation strategies show great potential in energy savingsEvaluation of energy savings related to building envelope retrofit techniques and ventilation

  3. CASE STUDY OF DUCT RETROFIT OF A 1985 HOME AND GUIDELINES FOR ATTIC AND CRAWL SPACE DUCT SEALING

    SciTech Connect (OSTI)

    Boudreaux, Philip R [ORNL; Christian, Jeffrey E [ORNL; Jackson, Roderick K [ORNL

    2012-01-01T23:59:59.000Z

    The U.S. Department of Energy (DOE) is fully committed to research for developing the information and capabilities necessary to provide cost-effective residential retrofits yielding 50% energy savings within the next several years. Heating, ventilation, and air conditioning (HVAC) is the biggest energy end use in the residential sector, and a significant amount of energy can be wasted through leaky ductwork in unconditioned spaces such as attics and crawl spaces. A detailed duct sealing case study is presented for one house along with nine brief descriptions of other duct retrofits completed in the mixed-humid climate. Costs and estimated energy savings are reported for most of the ten houses. Costs for the retrofits ranged from $0.92/ft2 to $1.80/ft2 of living space and estimated yearly energy cost savings due to the duct retrofits range from 1.8% to 18.5%. Lessons learned and duct sealing guidelines based on these ten houses, as well as close work with the HVAC industry in the mixed-humid climate of East Tennessee, northern Georgia, and south-central Kentucky are presented. It is hoped that the lessons learned and guidelines will influence local HVAC contractors, energy auditors, and homeowners when diagnosing or repairing HVAC duct leakage and will be useful for steering DOE s future research in this area.

  4. Building America Whole-House Solutions for Existing Homes: Cascade Apartments- Deep Energy Multifamily Retrofit (Fact Sheet)

    Broader source: Energy.gov [DOE]

    In December of 2009-10, King County Housing Authority implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington, which resulted in annual energy cost savings of 22%, improved comfort and air quality for residents, and increased durability of the units.

  5. A Meta-Analysis of Single-Family Deep Energy Retrofit Performance in the U.S.

    SciTech Connect (OSTI)

    Less, Brennan; Walker, Iain

    2014-03-01T23:59:59.000Z

    The current state of Deep Energy Retrofit (DER) performance in the U.S. has been assessed in 116 homes in the United States (US), using actual and simulated data gathered from the available domestic literature. Substantial airtightness reductions averaging 63% (n=48) were reported (two- to three-times more than in conventional retrofits), with average post-retrofit airtightness of 4.7 Air Changes per House at 50 Pascal (ACH50) (n=94). Yet, mechanical ventilation was not installed consistently. In order to avoid indoor air quality (IAQ) issues, all future DERs should comply with ASHRAE 62.2-2013 requirements or equivalent. Projects generally achieved good energy results, with average annual net-site and net-source energy savings of 47%±20% and 45%±24% (n=57 and n=35), respectively, and carbon emission reductions of 47%±22% (n=23). Net-energy reductions did not vary reliably with house age, airtightness, or reported project costs, but pre-retrofit energy usage was correlated with total reductions (MMBtu). Annual energy costs were reduced $1,283±$804 (n=31), from a pre-retrofit average of $2,738±$1,065 to $1,588±$561 post-retrofit (n=25 and n=39). The average reported incremental project cost was $40,420±$30,358 (n=59). When financed on a 30-year term, the median change in net-homeownership cost was only $1.00 per month, ranging from $149 in savings to an increase of $212 (mean=$15.67±$87.74; n=28), and almost half of the projects resulted in reductions in net-cost. The economic value of a DER may be much greater than is suggested by these net-costs, because DERs entail substantial non-energy benefits (NEBs), and retrofit measures may add value to a home at resale similarly to general remodeling, PV panel installation, and green/energy efficient home labels. These results provide estimates of the potential of DERs to address energy use in existing homes across climate zones that can be used in future estimates of the technical potential to reduce household energy use and greenhouse gas emissions through DERs.

  6. Changing nature of equipment and parts qualification

    SciTech Connect (OSTI)

    Bucci, R.M.

    1988-01-01T23:59:59.000Z

    Ideally, the original supplier of a piece of nuclear safety-related equipment has performed a qualification program and will continue to support that equipment throughout the lifetime of the nuclear power plants in which in equipment is installed. The supplier's nuclear quality assurance program will be maintained and he will continue to offer all necessary replacement parts. These parts will be identical to the original parts, certified to the original purchase order requirements, and the parts will be offered at competitive prices. Due to the changing nature of the nuclear plant equipment market, however, one or more of those ideal features are frequently unavailable when safety-related replacement equipment or parts are required. Thus, the process of equipment and parts qualification has had to adjust in order to ensure obtaining qualified replacements when needed. This paper presents some new directions taken in the qualification of replacement equipment and parts to meet changes in the marketplace.

  7. Field test evaluation of conservation retrofits of low-income, single-family buildings in Wisconsin: Audit field test implementation and results

    SciTech Connect (OSTI)

    McCold, L.N.; Schlegel, J.A.; O'Leary, L.; Hewitt, D.C.

    1988-06-01T23:59:59.000Z

    This report describes the field test of a retrofit audit. The field test was performed during the winter of 1985-86 in four south central Wisconsin counties. The purpose of the field test was to measure the energy savings and cost effectiveness of the audit-directed retrofit program for optimizing the program's benefit-to-cost ratio. The audit-directed retrofit program is described briefly in this report and in more detail by another report in this series (ORNL/CON-228/P3). The purpose of this report is to describe the methods and results of the field test. 3 refs., 7 figs., 10 tabs.

  8. Sandia National Laboratories: Earth Science: Facilities and Equipment

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ManagementEarth ScienceEarth Science: Facilities and Equipment Earth Science: Facilities and Equipment Geoscience Facilities and Equipment High-pressure thermalmechanical...

  9. Measured Effects of Retrofits - A Refrigerant Oil Additive and a Condenser Spray Device - On the Cooling Performance of a Heat Pump

    E-Print Network [OSTI]

    Levins, W. P.; Sand, J. R.; Baxter, V. D.; Linkous, R. S.

    1996-01-01T23:59:59.000Z

    A 15-year old, 3-ton single package air-to-air heat pump was tested in laboratory environmental chambers simulating indoor and outdoor conditions. After documenting initial performance, the unit was retrofitted with a prototype condenser water...

  10. Simulation of the Post-Retrofit Thermal Energy Use for the University Teaching Center (UTC) Building with the Use of Simplified System Models 

    E-Print Network [OSTI]

    Katipamula, S.; Claridge, D. E.

    1991-01-01T23:59:59.000Z

    Several state owned buildings with dual-duct constant volume (DDCV) systems have been retrofitted with energy efficient variable air volume systems (VAV) as part of the Texas LoanSTAR Program. One method of determining the energy savings resulting...

  11. Hygric Redistribution in Insulated Assemblies: Retrofitting Residential Envelopes Without Creating Moisture Issues

    SciTech Connect (OSTI)

    Smegal, J.; Lstiburek, J.

    2013-01-01T23:59:59.000Z

    The Building America program has recognized that most of the current housing stock is in need of energy related retrofits. One of the best ways of reducing the space conditioning energy consumption is to improve the thermal performance of the enclosure by adding exterior board foam insulation. This report quantifies the amount of water that can become trapped in the drainage cavity of typical wall systems, and measures the effect of water trapped in the drainage cavity on the moisture content of the sheathing. This study also attempts to explain the discrepancy between hygrothermal simulations and field performance of low permeance, low R-value exterior insulation (e.g. 3/4-in. foil faced polyisocyanurate) in cold climates.

  12. Urban driving cycle results of retrofitted diesel oxidation catalysts on heavy duty vehicles

    SciTech Connect (OSTI)

    Brown, K.F. [Engine Control Systems Ltd., Aurora, Ontario (Canada); Rideout, G.

    1996-09-01T23:59:59.000Z

    This paper presents the emissions testing results of various heavy duty engines and vehicles with and without retrofitted diesel oxidation catalyst technology. 1987 Cummins L10 and 1991 DDC 6V92TA DDECII engine results over the US Heavy Duty Transient Test are presented for comparison to chassis test results. The vehicles in this study include two urban buses, two school buses and three heavy duty trucks. The Central Business District, New York Bus and New York Composite urban driving cycles have been used to evaluate baseline emissions and the catalyst performance on a heavy duty chassis dynamometer. The results demonstrate that 25--45% particulate reduction is readily achievable on a wide variety of heavy duty vehicles. Significant carbon monoxide and hydrocarbon reductions were also observed.

  13. Low NO sub x /SO sub x Burner retrofit for utility cyclone boilers

    SciTech Connect (OSTI)

    Not Available

    1991-09-01T23:59:59.000Z

    This Public Design Report provides available nonproprietary design information on the Low NO{sub x}SO{sub x} Burner Retrofit of Utility Cyclone Boilers project. In addition to the design aspects, the history of the project, the organization of the project, and the role of the funding parties are discussed. An overview of the Low NO{sub x}SO{sub x} (LNS) Burner, the cyclone boiler and the Southern Illinois Power Cooperative host site is presented. A detailed nonproprietary description of the individual process steps, plant systems, and resulting performance then follows. Narrative process descriptions, simplified process flow diagrams, input/output stream data, operating conditions and requirements are given for each unit. The plant demonstration program and start up provisions, the environmental considerations and control, monitoring and safety factors that are considered are also addressed.

  14. Exploring Cost-Effective, High Performance Residential Retrofits for Affordable Housing in the Hot Humid Climate

    SciTech Connect (OSTI)

    McIlvaine, Janet; Sutherland, Karen; Schleith, Kevin; Chandra, Subrato

    2010-08-27T23:59:59.000Z

    In 2009, a Department of Energy Building America team led by the Florida Solar Energy Center began working with partners to find cost-effective paths for improving the energy performance of existing homes in the hot humid climate. A test-in energy audit and energy use modeling of the partner's proposed renovation package was performed for 41 affordable and middle income foreclosed homes in Florida and Alabama. HERS1 Indices ranged from 92 to 184 with modeled energy savings ranging from 3% to 50% (average of 26%). Analyses and recommendations were discussed with partners to encourage more efficient retrofits, highlight health and safety issues, and gather feedback on incremental cost of high performance measures. Ten completed renovations have modeled energy savings ranging from 9% to 48% (average 31%.) This paper presents the project's process including our findings thus far and highlights of the first home to meet the target HERS Index of 70.

  15. Energy Efficiency Retrofits for U.S. Housing: Removing the Bottlenecks

    E-Print Network [OSTI]

    Bardhan, Ashok; Jaffee, Dwight; Kroll, Cynthia; Wallace, Nancy

    2013-01-01T23:59:59.000Z

    HVAC • thermostat • water heater • lighting Billing analysisLeakage Appliances • Water heater • Refrigerator • Washinginsulated ducts  Windows  Water heater  Heating equipment 

  16. DEVELOPMENT OF A LOW-COST INFERENTIAL NATURAL GAS ENERGY FLOW RATE PROTOTYPE RETROFIT MODULE

    SciTech Connect (OSTI)

    E. Kelner; T.E. Owen; D.L. George; A. Minachi; M.G. Nored; C.J. Schwartz

    2004-03-01T23:59:59.000Z

    In 1998, Southwest Research Institute{reg_sign} began a multi-year project co-funded by the Gas Research Institute (GRI) and the U.S. Department of Energy. The project goal is to develop a working prototype instrument module for natural gas energy measurement. The module will be used to retrofit a natural gas custody transfer flow meter for energy measurement, at a cost an order of magnitude lower than a gas chromatograph. Development and evaluation of the prototype retrofit natural gas energy flow meter in 2000-2001 included: (1) evaluation of the inferential gas energy analysis algorithm using supplemental gas databases and anticipated worst-case gas mixtures; (2) identification and feasibility review of potential sensing technologies for nitrogen diluent content; (3) experimental performance evaluation of infrared absorption sensors for carbon dioxide diluent content; and (4) procurement of a custom ultrasonic transducer and redesign of the ultrasonic pulse reflection correlation sensor for precision speed-of-sound measurements. A prototype energy meter module containing improved carbon dioxide and speed-of-sound sensors was constructed and tested in the GRI Metering Research Facility at SwRI. Performance of this module using transmission-quality natural gas and gas containing supplemental carbon dioxide up to 9 mol% resulted in gas energy determinations well within the inferential algorithm worst-case tolerance of {+-}2.4 Btu/scf (nitrogen diluent gas measured by gas chromatograph). A two-week field test was performed at a gas-fired power plant to evaluate the inferential algorithm and the data acquisition requirements needed to adapt the prototype energy meter module to practical field site conditions.

  17. AMERICAN ELECTRIC POWER'S CONESVILLE POWER PLANT UNIT NO.5 CO2 CAPTURE RETROFIT STUDY

    SciTech Connect (OSTI)

    Carl R. Bozzuto; Nsakala ya Nsakala; Gregory N. Liljedahl; Mark Palkes; John L. Marion

    2001-06-30T23:59:59.000Z

    ALSTOM Power Inc.'s Power Plant Laboratories (ALSTOM) has teamed with American Electric Power (AEP), ABB Lummus Global Inc. (ABB), the US Department of Energy National Energy Technology Laboratory (DOE NETL), and the Ohio Coal Development Office (OCDO) to conduct a comprehensive study evaluating the technical feasibility and economics of alternate CO{sub 2} capture and sequestration technologies applied to an existing US coal-fired electric generation power plant. The motivation for this study was to provide input to potential US electric utility actions concerning GHG emissions reduction. If the US decides to reduce CO{sub 2} emissions, action would need to be taken to address existing power plants. Although fuel switching from coal to natural gas may be one scenario, it will not necessarily be a sufficient measure and some form of CO{sub 2} capture for use or disposal may also be required. The output of this CO{sub 2} capture study will enhance the public's understanding of control options and influence decisions and actions by government, regulators, and power plant owners in considering the costs of reducing greenhouse gas CO{sub 2} emissions. The total work breakdown structure is encompassed within three major reports, namely: (1) Literature Survey, (2) AEP's Conesville Unit No.5 Retrofit Study, and (3) Bench-Scale Testing and CFD Evaluation. The report on the literature survey results was issued earlier by Bozzuto, et al. (2000). Reports entitled ''AEP's Conesville Unit No.5 Retrofit Study'' and ''Bench-Scale Testing and CFD Evaluation'' are provided as companion volumes, denoted Volumes I and II, respectively, of the final report. The work performed, results obtained, and conclusions and recommendations derived therefrom are summarized.

  18. EnergyFit Nevada (formerly known as the Nevada Retrofit Initiative) final report and technical evaluation

    SciTech Connect (OSTI)

    Carvill, Anna; Bushman, Kate; Ellsworth, Amy

    2014-06-17T23:59:59.000Z

    The EnergyFit Nevada (EFN) Better Buildings Neighborhood Program (BBNP, and referred to in this document as the EFN program) currently encourages Nevada residents to make whole-house energy-efficient improvements by providing rebates, financing, and access to a network of qualified home improvement contractors. The BBNP funding, consisting of 34 Energy Efficiency Conservation Block Grants (EECBG) and seven State Energy Program (SEP) grants, was awarded for a three-year period to the State of Nevada in 2010 and used for initial program design and implementation. By the end of first quarter in 2014, the program had achieved upgrades in 553 homes, with an average energy reduction of 32% per home. Other achievements included: ? Completed 893 residential energy audits and installed upgrades in 0.05% of all Nevada single-family homes1 ? Achieved an overall conversation rate of 38.1%2 ? 7,089,089 kWh of modeled energy savings3 ? Total annual homeowner energy savings of approximately $525,7523 ? Efficiency upgrades completed on 1,100,484 square feet of homes3 ? $139,992 granted in loans to homeowners for energy-efficiency upgrades ? 29,285 hours of labor and $3,864,272 worth of work conducted by Nevada auditors and contractors4 ? 40 contractors trained in Nevada ? 37 contractors with Building Performance Institute (BPI) certification in Nevada ? 19 contractors actively participating in the EFN program in Nevada 1 Calculated using 2012 U.S. Census data reporting 1,182,870 homes in Nevada. 2 Conversion rate through March 31, 2014, for all Nevada Retrofit Initiative (NRI)-funded projects, calculated using the EFN tracking database. 3 OptiMiser energy modeling, based on current utility rates. 4 This is the sum of $3,596,561 in retrofit invoice value and $247,711 in audit invoice value.

  19. Pollution Control Equipment Tax Deduction (Alabama)

    Broader source: Energy.gov [DOE]

    The Pollution Control Equipment Tax Deduction allows businesses to deduct from their Alabama net worth the net amount invested in all devices, facilities, or structures, and all identifiable...

  20. Commercial and Industrial Kitchen Equipment Rebate Program

    Broader source: Energy.gov [DOE]

    NOTE: All equipment must be installed on or after January 1, 2015 through December 31, 2015. The documentation must be received no later than March 31, 2016. 

  1. Reduce Radiation Losses from Heating Equipment

    SciTech Connect (OSTI)

    Not Available

    2006-01-01T23:59:59.000Z

    This DOE Industrial Technologies Program tip sheet describes how to save energy and costs by reducing expensive heat losses from industrial heating equipment, such as furnaces.

  2. Electrical Equipment Inspection Program Electrical Safety

    E-Print Network [OSTI]

    Wechsler, Risa H.

    recognized hazards and meets code requirements Labeled. A nationally recognized testing laboratory (NRTL equipment as listed unless it is also labeled. Nationally recognized testing laboratory (NRTL

  3. assemblies equipment: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    capital equipment manufacturing plant : component level and assembly level inventory management MIT - DSpace Summary: Semiconductor capital equipment is manufactured in...

  4. Demonstration Assessment of Light-Emitting Diode (LED) Retrofit Lamps at the Lobby of the Bonneville Power Administration, Portland, OR

    SciTech Connect (OSTI)

    Miller, Naomi

    2011-07-01T23:59:59.000Z

    This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in the lobby of the Bonneville Power Administration (BPA) headquarters building in Portland, Oregon. The project involved a simple retrofit of 32 track lights used to illuminate historical black-and-white photos and printed color posters from the 1930s and 1940s. BPA is a federal power marketing agency in the Northwestern United States, and selected this prominent location to demonstrate energy efficient light-emitting diode (LED) retrofit options that not only can reduce the electric bill for their customers but also provide attractive alternatives to conventional products, in this case accent lighting for BPA's historical artwork.

  5. Universal null DTE (data terminal equipment)

    DOE Patents [OSTI]

    George, M.; Pierson, L.G.; Wilkins, M.E.

    1987-11-09T23:59:59.000Z

    A communication device in the form of data terminal equipment permits two data communication equipments, each having its own master clock and operating at substantially the same nominal clock rate, to communicate with each other in a multi-segment circuit configuration of a general communication network even when phase or frequency errors exist between the two clocks. Data transmitted between communication equipments of two segments of the communication network is buffered. A variable buffer fill circuit is provided to fill the buffer to a selectable extent prior to initiation of data output clocking. Selection switches are provided to select the degree of buffer preload. A dynamic buffer fill circuit may be incorporated for automatically selecting the buffer fill level as a function of the difference in clock frequencies of the two equipments. Controllable alarm circuitry is provided for selectively generating an underflow or an overflow alarm to one or both of the communicating equipments. 5 figs.

  6. Automatic monitoring of vibration welding equipment

    DOE Patents [OSTI]

    Spicer, John Patrick; Chakraborty, Debejyo; Wincek, Michael Anthony; Wang, Hui; Abell, Jeffrey A; Bracey, Jennifer; Cai, Wayne W

    2014-10-14T23:59:59.000Z

    A vibration welding system includes vibration welding equipment having a welding horn and anvil, a host device, a check station, and a robot. The robot moves the horn and anvil via an arm to the check station. Sensors, e.g., temperature sensors, are positioned with respect to the welding equipment. Additional sensors are positioned with respect to the check station, including a pressure-sensitive array. The host device, which monitors a condition of the welding equipment, measures signals via the sensors positioned with respect to the welding equipment when the horn is actively forming a weld. The robot moves the horn and anvil to the check station, activates the check station sensors at the check station, and determines a condition of the welding equipment by processing the received signals. Acoustic, force, temperature, displacement, amplitude, and/or attitude/gyroscopic sensors may be used.

  7. Generic seismic ruggedness of power plant equipment

    SciTech Connect (OSTI)

    Merz, K.L. (Anco Engineers, Inc., Culver City, CA (United States))

    1991-08-01T23:59:59.000Z

    This report updates the results of a program with the overall objective of demonstrating the generic seismic adequacy of as much nuclear power plant equipment as possible by means of collecting and evaluating existing seismic qualification test data. These data are then used to construct ruggedness'' spectra below which equipment in operating plants designed to earlier earthquake criteria would be generically adequate. This document is an EPRI Tier 1 Report. The report gives the methodology for the collection and evaluation of data which are used to construct a Generic Equipment Ruggedness Spectrum (GERs) for each equipment class considered. The GERS for each equipment class are included in an EPRI Tier 2 Report with the same title. Associated with each GERS are inclusion rules, cautions, and checklists for field screening of in-place equipment for GERS applicability. A GERS provides a measure of equipment seismic resistance based on available test data. As such, a GERS may also be used to judge the seismic adequacy of similar new or replacement equipment or to estimate the seismic margin of equipment re-evaluated with respect to earthquake levels greater than considered to date, resulting in fifteen finalized GERS. GERS for relays (included in the original version of this report) are now covered in a separate report (NP-7147). In addition to the presentation of GERS, the Tier 2 report addresses the applicability of GERS to equipment of older vintage, methods for estimating amplification factors for evaluating devices installed in cabinets and enclosures, and how seismic test data from related studies relate to the GERS approach. 28 refs., 5 figs., 4 tabs.

  8. A Study of Environmental Load Reduction Technique for University Facilities Part10 Retrofitting heat source based on diagnostic results

    E-Print Network [OSTI]

    Miyashita, Yasushi

    -conditioning system in university facilities. Authors analyze the effect of CO2 emission reduction by retrofit. Simulation tools used are FACES and LCEM. 1. CO2 CO2 (TSCP)1)2006 2012CO215 TSCP 2. 1200 CO2 35 1000ton-CO2 35 75 CO2 2) 1 30 24CO2 15 1 RC 5 1 16,510m2 10131m2 6379m2

  9. Roof and Attic Design Guidelines for new and retrofit Construction of Homes in Hot and Coild Climates

    SciTech Connect (OSTI)

    Desjarlais, Andre Omer [ORNL] [ORNL; LaFrance, Marc [International Energy Agency] [International Energy Agency

    2013-01-01T23:59:59.000Z

    Some guidelines for improving the energy efficiency of roofs and attics are presented and are based on the research of the DOE Building Technology. The results of combined analytical and experimental studies were used to benchmark computer tools, which in turn, were used to simulate homes in hot and cold climates. Adding floor and roof insulation, above deck ventilation, radiant barriers, cool color shingle, metal or tile roofs, sealing the attic floor, sealing the duct system and sealing the attic were simulated to compute the cost of energy savings. Results are prioritized to help building owners make an informed economic decision when contemplating roof and attic retrofits. Sealing the attic floor is a top retrofit option. The sealed attic approach and a new prototype roof assembly an insulated and ventilated roof are good options for retrofit work but have paybacks ranging from 15 to 25 years. A new sealed attic concept was simulated and computations show its simple payback is about 10 to 12 years in hot and cold climates; its first cost is significantly reduced from that of a spray foam approach. For new construction the best option is to keep the ducts out of the attic, make sure the attic floor is sealed and add at least code level of insulation to the ceiling.

  10. Low No{sub x}/SO{sub x} burner retrofit for utility cyclone boilers. Baseline test report: Issue A

    SciTech Connect (OSTI)

    Moore, K.; Martin, L.; Smith, J.

    1991-05-01T23:59:59.000Z

    The Low NO{sub x}/SO{sub x} (LNS) Burner Retrofit for Utility Cyclone Boilers program consists of the retrofit and subsequent demonstration of the technology at Southern Illinois Power Cooperative`s (SIPC`s) 33-MW unit 1 cyclone boiler located near Marion, Illinois. The LNS Burner employs a simple innovative combustion process burning high-sulfur Illinois coal to provide substantial SO{sub 2} and NO{sub x} control within the burner. A complete series of boiler performance and characterization tests, called the baseline tests, was conducted in October 1990 on unit 1 of SIPC`s Marion Station. The primary objective of the baseline test was to collect data from the existing plant that could provide a comparison of performance after the LNS Burner retrofit. These data could confirm the LNS Burner`s SO{sub x} and NO{sub x} emissions control and any effect on boiler operation. Further, these tests would provide to the project experience with the operating characteristics of the host unit as well as engineering design information to minimize technical uncertainties in the application of the LNS Burner technology.

  11. Thermal response of process equipment to hydrocarbon fires

    SciTech Connect (OSTI)

    Solberg, D.M.; Borgnes, O.

    1983-01-01T23:59:59.000Z

    Requirements for active fire-fighting equipment such as fixed and portable powder extinguishers, foam generators, water guns, and deluge systems, are given in various codes and standards. However, very little is to be found about fire design conditions and passive fire protection. For safety verification of process plants and for designing adequate passive fire protection it is necessary to know the total incident heat fluxes which can occur under realistic conditions and the effects that such heat fluxes may have on process equipment and structures. During the last few years, Det Norske Veritas has been invloved in investigations aimed at estimating realistic fire loads from different types of hydrocarbon fires and the thermal response of process equipment and structures exposed to such fires. These investigations are still in progress and are especially focused on the conditions on off-shore oil and gas production platforms. However, many fire problems will be the same in the land-based process industry. The present paper concentrates on the thermal response of pipes and vessels exposed to a severe hydrocarbon fire with a defined thermal load. (JMT)

  12. The Use of Variable Speed Drives to Retrofit Hydraulic Injection Molding Machines

    E-Print Network [OSTI]

    Ambs, L.; Frerker, M. M.

    Research Institute, Palo Alto, California. 8.) Remley, Carl H. (1993) "Measured performance of variable speed drives on injection molding hydraulic pumps." Energy Management Consulting and Equipment, Inc., North Attleboro, Massachusetts'. 9.) Rosato...

  13. Estimation of Energy Baseline by Simulation for On-going Commissioning and Energy Saving Retrofit 

    E-Print Network [OSTI]

    Miyata, M.; Yoshida, H.; Asada, M.; Iwata, T.; Tanabe, Y.; Yanagisawa, T.

    2006-01-01T23:59:59.000Z

    This paper proposes a method of estimating the adjusted energy baseline using simulation models, which can calculate the energy baseline with various conditions, such as conditions of weather, occupancy and equipment operations. Especially...

  14. Solar and Wind Energy Equipment Exemption

    Broader source: Energy.gov [DOE]

    In Wisconsin, any value added by a solar-energy system or a wind-energy system is exempt from general property taxes. A solar-energy system is defined as "equipment which directly converts and then...

  15. Heavy Mobile Equipment Mechanic (One Mechanic Shop)

    Broader source: Energy.gov [DOE]

    The position is a Heavy Mobile Equipment Mechanic (One Mechanic Shop) located in Kent, Washington, and will be responsible for the safe and efficient operation of a field garage performing...

  16. Biomass Equipment & Materials Compensating Tax Deduction

    Broader source: Energy.gov [DOE]

    In 2005, New Mexico adopted a policy to allow businesses to deduct the value of biomass equipment and biomass materials used for the processing of biopower, biofuels, or biobased products in...

  17. Clark Public Utilities- Solar Energy Equipment Loan

    Broader source: Energy.gov [DOE]

    Clark Public Utilities offers financing available to its customers for the purchase and installation of residential solar equipment. Loans up to $10,000 are available for solar pool heaters and...

  18. Hot conditioning equipment conceptual design report

    SciTech Connect (OSTI)

    Bradshaw, F.W., Westinghouse Hanford

    1996-08-06T23:59:59.000Z

    This report documents the conceptual design of the Hot Conditioning System Equipment. The Hot conditioning System will consist of two separate designs: the Hot Conditioning System Equipment; and the Hot Conditioning System Annex. The Hot Conditioning System Equipment Design includes the equipment such as ovens, vacuum pumps, inert gas delivery systems, etc.necessary to condition spent nuclear fuel currently in storage in the K Basins of the Hanford Site. The Hot Conditioning System Annex consists of the facility of house the Hot Conditioning System. The Hot Conditioning System will be housed in an annex to the Canister Storage Building. The Hot Conditioning System will consist of pits in the floor which contain ovens in which the spent nuclear will be conditioned prior to interim storage.

  19. Industrial Equipment Demand and Duty Factors

    E-Print Network [OSTI]

    Dooley, E. S.; Heffington, W. M.

    Demand and duty factors have been measured for selected equipment (air compressors, electric furnaces, injection molding machines, centrifugal loads, and others) in industrial plants. Demand factors for heavily loaded air compressors were near 100...

  20. Biomass Equipment and Materials Compensating Tax Deduction

    Broader source: Energy.gov [DOE]

    In 2005 New Mexico adopted a policy to allow businesses to deduct the value of biomass equipment and biomass materials used for the processing of biopower, biofuels or biobased products in...

  1. Tax Credit for Renewable Energy Equipment Manufacturers

    Broader source: Energy.gov [DOE]

    The Tax Credit for Renewable Energy Resource Equipment Manufacturing Facilities was enacted as a part of Oregon's Business Energy Tax Credit (BETC) in July 2007, with the passage of HB 3201. The ...

  2. Property Tax Assessment for Renewable Energy Equipment

    Broader source: Energy.gov [DOE]

    HB 2403 of 2014 clarified that depreciation should be determined using straight-line depreciation over the useful life of the equipment. The taxable original cost equals the original cost of the...

  3. Equipment Energy Models Using Spreadsheet Programs

    E-Print Network [OSTI]

    Gilbert, J. S.

    EQUIPMENT ENERGY MODELS USING SPREADSHEET PROGRAMS Joel S. Gilbert, Dames & Moore, Bethesda, Maryland Engineering calculations on PC's are undergoing a revolution with the advent of spreadsheet programs. The author has found that virtually all...

  4. Consider Steam Turbine Drives for Rotating Equipment

    SciTech Connect (OSTI)

    Not Available

    2006-01-01T23:59:59.000Z

    This revised ITP tip sheet on steam turbine drives for rotating equipment provides how-to advice for improving the system using low-cost, proven practices and technologies.

  5. Dairy Manure Handling Systems and Equipment.

    E-Print Network [OSTI]

    Sweeten, John M.

    1983-01-01T23:59:59.000Z

    The Texas A&M University System ? Texas Agricultural Extension Service Zerle L. Carpenter, Director College Station 8?1446 DAIRY MANURE HANDLING SYSTEMS AND EQUIPMENT DAIRY MANURE HANDLING SYSTEMS AND EQUIPMENT John M. Sweeten, Ph....D., P.E.* A manure management system for a modern dairy should be capable of controlling solid or liquid manure and wastewater from the open corrals (manure and rainfall runoff), free stall barn , feeding barn , holding lot or holding shed , milking...

  6. Experience gained from equipment qualification inspections

    SciTech Connect (OSTI)

    Jacobus, M.J.

    1986-01-01T23:59:59.000Z

    This paper describes issues which have been identified during equipment qualification inspections. Generic qualification information is discussed first, such as qualification bases, utility/supplier interfaces, file auditability, and generic environmental qualification. Next, technical strategies with specific examples are discussed. Issues covered include functional performance requirements, post accident qualification, similarity, installation and interfaces, maintenance, aging, and testing. Finally, additions and deletions to equipment qualification master lists and environmental enveloping are discussed.

  7. University of Toronto Page 1 of 12 Emergency Eyewash and Shower Equipment Standard

    E-Print Network [OSTI]

    Simmons, Craig A.

    is exposed to a potential hazard of injury to the skin due to contact with a substance, a quick-acting deluge, and there is a possibility of eye contact occurring. Deluge Showers Laboratories Plumbed emergency shower equipment shall an MSDS for the materials used specifies the use of a deluge shower in case of skin contact

  8. Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring

    SciTech Connect (OSTI)

    Dentz, J.; Henderson, H.; Varshney, K.

    2014-09-01T23:59:59.000Z

    The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

  9. Review of Prior Commercial Building Energy Efficiency Retrofit Evaluation: A Report to Snohomish Public Utilities District

    SciTech Connect (OSTI)

    Price, Phillip

    2014-12-22T23:59:59.000Z

    Snohomish County Public Utilities District (the District or Snohomish PUD) provides electricity to about 325,000 customers in Snohomish County, Washington. The District has an incentive programs to encourage commercial customers to improve energy efficiency: the District partially reimburses the cost of approved retrofits if they provide a level of energy performance improvement that is specified by contract. In 2013 the District contracted with Lawrence Berkeley National Laboratory to provide a third-party review of the Monitoring and Verification (M&V) practices the District uses to evaluate whether companies are meeting their contractual obligations. This work helps LBNL understand the challenges faced by real-world practitioners of M&V of energy savings, and builds on a body of related work such as Price et al. (2013). The District selected a typical project for which they had already performed an evaluation. The present report includes the District's original evaluation as well as LBNL's review of their approach. The review is based on the document itself; on investigation of the load data and outdoor air temperature data from the building evaluated in the document; and on phone discussions with Bill Harris of the Snohomish County Public Utilities District. We will call the building studied in the document the subject building, the original Snohomish PUD report will be referred to as the Evaluation, and this discussion by LBNL is called the Review.

  10. Building America Best Practices Series, Volume 10: Retrofit Techniques and Technologies: Air Sealing

    SciTech Connect (OSTI)

    Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.; Cole, Pamala C.; Williamson, Jennifer L.; Love, Pat M.

    2010-04-12T23:59:59.000Z

    This report was prepared by PNNL for the U.S. Department of Energy Building America Program. The report provides information to home owners who want to make their existing homes more energy efficient by sealing leaks in the building envelope (ceiling, walls, and floors) that let in drafts and let conditioned air escape. The report provides descriptions of 19 key areas of the home where air sealing can improve home performance and energy efficiency. The report includes suggestions on how to find a qualified weatherization or home performance contractor, what to expect in a home energy audit, opportune times for performing air sealing, and what safety and health concerns to be aware of. The report describes some basic building science concepts and topics related to air sealing including ventilation, diagnostic tools, and code requirements. The report will be available for free download from the DOE Building America website. It is a suitable consumer education tool for home performance and weatherization contractors to share with customers to describe the process and value of home energy retrofits.

  11. Electricity Used by Office Equipment and Network Equipment in the U.S.: Detailed Report and Appendices

    E-Print Network [OSTI]

    LBNL-45917 Electricity Used by Office Equipment and Network Equipment in the U.S.: Detailed Report..............................................................................................46 #12;#12;1 Electricity Used by Office Equipment and Network Equipment in the U.S. Kaoru Kawamoto and network equipment, there has been no recent study that estimates in detail how much electricity

  12. Key changes in proteins occur in cyanobacteria | EMSL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    proteins occur in cyanobacteria Identification of redox-sensitive enzymes can enrich biofuel production research Overview of the chemical biology technique used by PNNL...

  13. Determining Planes Along Which Earthquakes Occur- Method of Applicatio...

    Open Energy Info (EERE)

    Along Which Earthquakes Occur- Method of Application to Earthquakes Accompanying Hydraulic Fracturing Jump to: navigation, search OpenEI Reference LibraryAdd to library...

  14. michael smith ornlradioactive beams: equipment & techniques recoil separators

    E-Print Network [OSTI]

    michael smith ornlradioactive beams: equipment & techniques recoil separators approach! · directly Smith, Rolfs, Barnes NIMA306 (1991) 233 #12;michael smith ornlradioactive beams: equipment & techniques;michael smith ornlradioactive beams: equipment & techniques recoil separators proof of concept with 12C

  15. Cold-Start Emissions Control in Hybrid Vehicles Equipped with...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Emissions Control in Hybrid Vehicles Equipped with a Passive Adsorber for Hydrocarbons and NOx Cold-Start Emissions Control in Hybrid Vehicles Equipped with a Passive Adsorber for...

  16. Abatement of Air Pollution: Air Pollution Control Equipment and...

    Broader source: Energy.gov (indexed) [DOE]

    These regulations contain instructions for the operation and monitoring of air pollution control equipment, as well as comments on procedures in the event of equipment breakdown,...

  17. Dispensing Equipment Testing With Mid-Level Ethanol/Gasoline...

    Energy Savers [EERE]

    Dispensing Equipment Testing With Mid-Level EthanolGasoline Test Fluid Dispensing Equipment Testing With Mid-Level EthanolGasoline Test Fluid The National Renewable Energy...

  18. advanced electronic equipment: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    common equipment through predetermined global ... Chouinard, Natalie, 1979- 2009-01-01 85 Logging Equipment and Loren Kellogg Renewable Energy Websites Summary: and the control is...

  19. Southwest Gas Corporation- Commercial Energy Efficient Equipment Rebate Program

    Broader source: Energy.gov [DOE]

    Southwest Gas Corporation (SWG) offers rebates to commercial customers in Nevada who purchase energy efficient natural gas equipment. Eligible equipment includes clothes washers, storage water...

  20. Southwest Gas Corporation- Commercial High-Efficiency Equipment Rebate Program

    Broader source: Energy.gov [DOE]

    Southwest Gas Corporation (SWG) offers rebates to commercial customers in Arizona who purchase energy efficient natural gas equipment. Eligible equipment includes natural gas storage and tankless...

  1. Modular Process Equipment for Low Cost Manufacturing of High...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Process Equipment for Low Cost Manufacturing of High Capacity Prismatic Li-Ion Cell Alloy Anodes Modular Process Equipment for Low Cost Manufacturing of High Capacity Prismatic...

  2. Master equipment list -- Phase 1. Revision 1

    SciTech Connect (OSTI)

    Jech, J.B.

    1995-04-28T23:59:59.000Z

    The purpose of this document is to define the system requirements for the Master Equipment List (MEL) Phase 1 project. The intended audience for this document includes Data Automation Engineering (DAE), Configuration Management Improvement and Control Engineering (CMI and CE), Data Administration Council (DAC), and Tank Waste Remedial System (TWRS) personnel. The intent of Phase 1 is to develop a user-friendly system to support the immediate needs of the TWRS labeling program. Phase 1 will provide CMI and CE the ability to administrate, distribute, and maintain key information generated by the labeling program. CMI and CE is assigning new Equipment Identification Numbers (EINs) to selected equipment in Tank Farms per the TWRS Data Standard ``Tank Farm Equipment Identification Number``. The MEL Phase 1 system will be a multi-user system available through the HLAN network. It will provide basic functions such as view, query, and report, edit, data entry, password access control, administration and change control. The scope of Phase 1 data will encompass all Tank Farm Equipment identified by the labeling program. The data will consist of fields from the labeling program`s working database, relational key references and pointers, safety class information, and field verification data.

  3. Original article Hydraulic conductance of two co-occuring neotropical

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Original article Hydraulic conductance of two co-occuring neotropical understory shrubs December 1999) Abstract ­ Whole plant hydraulic conductance was measured for two co-occuring neotropical hydraulic con- ductance and leaf specific conducance in the drought-avoiding species, P. trigonum, than

  4. Security Equipment and Systems Certification Program (SESCP)

    SciTech Connect (OSTI)

    Steele, B.J. [Sandia National Labs., Albuquerque, NM (United States); Papier, I.I. [Underwriters Labs., Inc., Northbrook, IL (United States)

    1996-06-20T23:59:59.000Z

    Sandia National Laboratories (SNL) and Underwriters Laboratories, Inc., (UL) have jointly established the Security Equipment and Systems Certification Program (SESCP). The goal of this program is to enhance industrial and national security by providing a nationally recognized method for making informed selection and use decisions when buying security equipment and systems. The SESCP will provide a coordinated structure for private and governmental security standardization review. Members will participate in meetings to identify security problems, develop ad-hoc subcommittees (as needed) to address these identified problems, and to maintain a communications network that encourages a meaningful exchange of ideas. This program will enhance national security by providing improved security equipment and security systems based on consistent, reliable standards and certification programs.

  5. The Great Building Energy Predictor Shootout II: Measuring Retrofit Energy Savings

    E-Print Network [OSTI]

    Thamilseran, S.; Haberl, J. S.

    1995-01-01T23:59:59.000Z

    series plot of measured energy use in ZEC for the period of Jan. 1,990 to Nov.27,1990 for (a) Whole-Building Electricity, (b) Motor Control Center Electricity, (c) Light and Equipment Electricity, (d) Whole-Building Cooling, and (e) Whole-Building Heating... channels. 1.2 Time series plots of predicted energy use by Entry #1 and residual energy use in ZEC for the period of Jan.1,990 to Nov.27,1990 for (a) Whole-Building Electricity, (b) Motor Control Center Electricity, (c) Light and Equipment Electricity, (d...

  6. Cost-Benefit Analysis of Flexibility Retrofits for Coal and Gas-Fueled Power Plants: August 2012 - December 2013

    SciTech Connect (OSTI)

    Venkataraman, S.; Jordan, G.; O'Connor, M.; Kumar, N.; Lefton, S.; Lew, D.; Brinkman, G.; Palchak, D.; Cochran, J.

    2013-12-01T23:59:59.000Z

    High penetrations of wind and solar power plants can induce on/off cycling and ramping of fossil-fueled generators. This can lead to wear-and-tear costs and changes in emissions for fossil-fueled generators. Phase 2 of the Western Wind and Solar Integration Study (WWSIS-2) determined these costs and emissions and simulated grid operations to investigate the full impact of wind and solar on the fossil-fueled fleet. This report studies the costs and benefits of retrofitting existing units for improved operational flexibility (i.e., capability to turndown lower, start and stop faster, and ramp faster between load set-points).

  7. Energy Implications of Retrofitting Retail Sector Rooftop Units with Stepped-Speed and Variable-Speed Functionality

    SciTech Connect (OSTI)

    Studer, D.; Romero, R.; Herrmann, L.; Benne, K.

    2012-04-01T23:59:59.000Z

    Commercial retailers understand that retrofitting constant-speed RTU fan motors with stepped- or variable-speed alternatives could save significant energy in most U.S. climate zones. However, they lack supporting data, both real-world and simulation based, on the cost effectiveness and climate zone-specific energy savings associated with this measure. Thus, building managers and engineers have been unable to present a compelling business case for fan motor upgrades to upper management. This study uses whole-building energy simulation to estimate the energy impact of this type of measure so retailers can determine its economic feasibility.

  8. DEVELOPMENT OF A LOW COST INFERENTIAL NATURAL GAS ENERGY FLOW RATE PROTOTYPE RETROFIT MODULE

    SciTech Connect (OSTI)

    E. Kelner; D. George; T. Morrow; T. Owen; M. Nored; R. Burkey; A. Minachi

    2005-05-01T23:59:59.000Z

    In 1998, Southwest Research Institute began a multi-year project to develop a working prototype instrument module for natural gas energy measurement. The module will be used to retrofit a natural gas custody transfer flow meter for energy measurement, at a cost an order of magnitude lower than a gas chromatograph. Development and evaluation of the prototype energy meter in 2002-2003 included: (1) refinement of the algorithm used to infer properties of the natural gas stream, such as heating value; (2) evaluation of potential sensing technologies for nitrogen content, improvements in carbon dioxide measurements, and improvements in ultrasonic measurement technology and signal processing for improved speed of sound measurements; (3) design, fabrication and testing of a new prototype energy meter module incorporating these algorithm and sensor refinements; and (4) laboratory and field performance tests of the original and modified energy meter modules. Field tests of the original energy meter module have provided results in close agreement with an onsite gas chromatograph. The original algorithm has also been tested at a field site as a stand-alone application using measurements from in situ instruments, and has demonstrated its usefulness as a diagnostic tool. The algorithm has been revised to use measurement technologies existing in the module to measure the gas stream at multiple states and infer nitrogen content. The instrumentation module has also been modified to incorporate recent improvements in CO{sub 2} and sound speed sensing technology. Laboratory testing of the upgraded module has identified additional testing needed to attain the target accuracy in sound speed measurements and heating value.

  9. dieSel/heAvy equipMent College of Rural and Community Development

    E-Print Network [OSTI]

    Hartman, Chris

    907-455-2809 www.ctc.uaf.edu/programs/diesel/ certificate Minimum Requirements for Certificate: 36 credits The diesel and heavy equipment mechanics program offers the student training in the maintenance and equipment overhauls. Students work on large truck fuel, electrical and air systems, diesel engines

  10. Conceptual design report, CEBAF basic experimental equipment

    SciTech Connect (OSTI)

    NONE

    1990-04-13T23:59:59.000Z

    The Continuous Electron Beam Accelerator Facility (CEBAF) will be dedicated to basic research in Nuclear Physics using electrons and photons as projectiles. The accelerator configuration allows three nearly continuous beams to be delivered simultaneously in three experimental halls, which will be equipped with complementary sets of instruments: Hall A--two high resolution magnetic spectrometers; Hall B--a large acceptance magnetic spectrometer; Hall C--a high-momentum, moderate resolution, magnetic spectrometer and a variety of more dedicated instruments. This report contains a short description of the initial complement of experimental equipment to be installed in each of the three halls.

  11. Criticality safety concerns of uranium deposits in cascade equipment

    SciTech Connect (OSTI)

    Plaster, M.J. [Lockheed Martin Utility Services, Inc., Piketon, OH (United States)

    1996-12-31T23:59:59.000Z

    The Paducah and Portsmouth Gaseous Diffusion Plants enrich uranium in the {sup 235}U isotope by diffusing gaseous uranium hexafluoride (UF{sub 6}) through a porous barrier. The UF{sub 6} gaseous diffusion cascade utilized several thousand {open_quotes}stages{close_quotes} of barrier to produce highly enriched uranium (HEU). Historically, Portsmouth has enriched the Paducah Gaseous Diffusion Plant`s product (typically 1.8 wt% {sup 235}U) as well as natural enrichment feed stock up to 97 wt%. Due to the chemical reactivity of UF{sub 6}, particularly with water, the formation of solid uranium deposits occur at a gaseous diffusion plant. Much of the equipment operates below atmospheric pressure, and deposits are formed when atmospheric air enters the cascade. Deposits may also be formed from UF{sub 6} reactions with oil, UF{sub 6} reactions with the metallic surfaces of equipment, and desublimation of UF{sub 6}. The major deposits form as a result of moist air in leakage due to failure of compressor casing flanges, blow-off plates, seals, expansion joint convolutions, and instrument lines. This report describes criticality concerns and deposit disposition.

  12. Can combining economizers with improved filtration save energy and protect equipment in data centers?

    E-Print Network [OSTI]

    Shehabi, Arman

    2009-01-01T23:59:59.000Z

    by potential equipment reliability concerns associated withblack carbon; equipment reliability; energy efficiency 1.potential equipment reliability concerns associated with

  13. Can combining economizers with improved filtration save energy and protect equipment in data centers?

    E-Print Network [OSTI]

    Shehabi, Arman

    2010-01-01T23:59:59.000Z

    by potential equipment reliability concerns associated withblack carbon; equipment reliability; energy efficiency 1.potential equipment reliability concerns associated with

  14. On Storage Operators LAMA -Equipe de Logique

    E-Print Network [OSTI]

    Nour, Karim

    On Storage Operators Karim NOUR LAMA - Equipe de Logique Universit´e de Savoie 73376 Le Bourget du Lac e-mail nour@univ-savoie.fr Abstract In 1990 Krivine (1990b) introduced the notion of storage shown that there is a very simple type in the AF2 type system for storage operators using Godel

  15. Test and Test Equipment Joshua Lottich

    E-Print Network [OSTI]

    Patel, Chintan

    Test and Test Equipment Joshua Lottich CMPE 640 11/23/05 #12;Testing Verifies that manufactured chip meets design specifications. Cannot test for every potential defect. Modeling defects as faults allows for passing and failing of chips. Ideal test would capture all defects and pass only chips

  16. Right-Size Heating and Cooling Equipment

    SciTech Connect (OSTI)

    Not Available

    2002-01-01T23:59:59.000Z

    This is one of a series of technology fact sheets created to help housing designers and builders adopt a whole-house design approach and energy efficient design practices. The fact sheet helps people choose the correct equipment size for heating and cooling to improve comfort and reduce costs, maintenance, and energy use.

  17. Right-Sizing Laboratory Equipment Loads

    SciTech Connect (OSTI)

    Frenze, David; Greenberg, Steve; Mathew, Paul; Sartor, Dale; Starr, William

    2005-11-29T23:59:59.000Z

    Laboratory equipment such as autoclaves, glass washers, refrigerators, and computers account for a significant portion of the energy use in laboratories. However, because of the general lack of measured equipment load data for laboratories, designers often use estimates based on 'nameplate' rated data, or design assumptions from prior projects. Consequently, peak equipment loads are frequently overestimated. This results in oversized HVAC systems, increased initial construction costs, and increased energy use due to inefficiencies at low part-load operation. This best-practice guide first presents the problem of over-sizing in typical practice, and then describes how best-practice strategies obtain better estimates of equipment loads and right-size HVAC systems, saving initial construction costs as well as life-cycle energy costs. This guide is one in a series created by the Laboratories for the 21st Century ('Labs21') program, a joint program of the U.S. Environmental Protection Agency and U.S. Department of Energy. Geared towards architects, engineers, and facilities managers, these guides provide information about technologies and practices to use in designing, constructing, and operating safe, sustainable, high-performance laboratories.

  18. An Approach to Evaluating Equipment Efficiency Policies 

    E-Print Network [OSTI]

    Newsom, D. E.; Evans, A. R.

    1980-01-01T23:59:59.000Z

    of several types of industr~al equipment to evaluate the technical and economic feasibility of labeling rules and minimum energy effic~ency standards. An approach to the evaluation of these and related policy options is under development. Th~ approach...

  19. APOLLO PROGRAM LUNAR SURFACE EQUIPMENT STATUS

    E-Print Network [OSTI]

    Rathbun, Julie A.

    APOLLO PROGRAM LUNAR SURFACE EQUIPMENT STATUS 3 JUNE 1974 NOTE: Discussions of closed problems COMPOSITION EXPERIMENT ZERO OFFSET . . . . . . . . . . . . . 3.6 APOLLO 14 ALSEP COLD CATHODE ION GAUGE EXPERIMENT INTERMITTENT SCIENCE DATA. 3.7 APOLLO 15 ALSEP COLD CATHODE ION GAUGE EXPERIMENT NOISY DATA

  20. APOLLO PROGRAM LUNAR SURFACE EQUIPMENT STATUS

    E-Print Network [OSTI]

    Rathbun, Julie A.

    APOLLO PROGRAM LUNAR SURFACE EQUIPMENT STATUS 18 SEPTEMBER 1973 NOTE: Discussions of closed-14 4-18 4-19 ZERO OFFSET. . . · . . . . . . . · . . . . . . . 4-20 4. 6 APOLLO 14 ALSEP COLD CATHODE ION GAUGE EXPERIMENT INTERMITTENT SCIENCE DATA 4. ? APOLLO 15 ALSEP COLD CATHODE ION GAUGE EXPERIMENT

  1. APOLLO PROGRAM LUNAR SURFACE EQUIPMENT STATUS

    E-Print Network [OSTI]

    Rathbun, Julie A.

    APOLLO PROGRAM LUNAR SURFACE EQUIPMENT STATUS 1 DECEMBER 1973 NOTE: Discussions of closed problems. · · · . · · . · · . · . . · . . CLOSED 4.6 APOLLO 14 ALSEP COLD CATHODE ION GAUGE EXPERIMENT INTERMITTENT SCIENCE DATA · . · CLOSED 4.7 APOLLO 15 ALSEP COLD CATHODE ION GAUGE EXPERIMENT NOISY DATA AND INTERMITTENT AUTOMATIC ZERO

  2. APOLLO PROGRAM LUNAR SURFACE EQUIPMENT STATUS

    E-Print Network [OSTI]

    Rathbun, Julie A.

    APOLLO PROGRAM LUNAR SURFACE EQUIPMENT STATUS 1 MARCH 1974 NOTE: Discussions of closed problems. . . . . . . . . . · . . . APOLLO 14 ALSEP COLD CATHODE ION GAUGE EXPERIMENT INTERMITTENT SCIENCE DATA · . APOLLO 15 ALSEP COLD . . . . 0 . . . . . APOLLO 15 LUNAR SURFACE MAGNETOMETER LOSS OF SCIENTIFIC AND ENGINEERING DATA. APOLLO 14

  3. Equipment Policy for Federal Sponsored Effective Date

    E-Print Network [OSTI]

    Fernandez, Eduardo

    Property Manager I. Background Division of Research Florida Atlantic University is required to comply. Equipment shall be defined as an article of nonexpendable tangible personal property. Florida Atlantic and a useful life of more than one year. III. General Statement Research Accounting and Property Management

  4. Electrical Equipment Replacement: Energy Efficiency versus System Compatibility

    E-Print Network [OSTI]

    Massey, G. W.

    2005-01-01T23:59:59.000Z

    upgrading electrical equipment to energy efficient models, including conductor sizing, overcurrent protective devices, grounding, and harmonics. The pages that follow provide guidance in the decision-making process when replacing electrical equipment... equipment. Several areas of compatibility must be addressed for equipment to work properly. Critical areas of concern are conductor sizing, overcurrent protection devices, grounding, and harmonics. Conductor Sizing Conductors are sized...

  5. THE GAME, FIELD, PLAYERS AND EQUIPMENT General Rules

    E-Print Network [OSTI]

    Baltisberger, Jay H.

    metal cleats are permitted. (See illegal player equipment) Game and Player Equipment (Illegal) 1. A player wearing illegal equipment shall not be permitted to play. This applies to any equipment, which be declared illegal include: A. Headgear containing any hard, unyielding, or stiff material, including billed

  6. Field Demonstration of Active Desiccant Modules Designed to Integrate with Standard Unitary Rooftop Package Equipment - Final Report: Phase 3

    SciTech Connect (OSTI)

    Fischer, J

    2004-03-15T23:59:59.000Z

    This report summarizes the investigation of two active desiccant module (ADM) pilot site installations initiated in 2001. Both pilot installations were retrofits at existing facilities served by conventional heating, ventilating, and air-conditioning (HVAC) systems that had encountered frequent humidity control, indoor air quality (IAQ), and other operational problems. Each installation involved combining a SEMCO, Inc., ADM (as described in Fischer and Sand 2002) with a standard packaged rooftop unit built by the Trane Company. A direct digital control (DDC) system integral to the ADM performed the dual function of controlling the ADM/rooftop combination and facilitating data collection, trending, and remote performance monitoring. The first installation involved providing preconditioned outdoor air to replace air exhausted from the large kitchen hood and bathrooms of a Hooters restaurant located in Rome, Georgia. This facility had previously added an additional rooftop unit in an attempt to achieve occupant comfort without success. The second involved conditioning the outdoor air delivered to each room of a wing of the Mountain Creek Inn at the Callaway Gardens resort. This hotel, designed in the ''motor lodge'' format with each room opening to the outdoors, is located in southwest Georgia. Controlling the space humidity always presented a serious challenge. Uncomfortable conditions and musty odors had caused many guests to request to move to other areas within the resort. This is the first field demonstration performed by Oak Ridge National Laboratory where significant energy savings, operating cost savings, and dramatically improved indoor environmental conditions can all be claimed as the results of a retrofit desiccant equipment field installation. The ADM/rooftop combination installed at the restaurant resulted in a reduction of about 34% in the electricity used by the building's air-conditioning system. This represents a reduction of approximately 15% in overall electrical energy consumption and a 12.5-kW reduction in peak demand. The cost of gas used for regeneration of the desiccant wheel over this period of time is estimated to be only $740, using a gas cost of $0.50 per therm--the summer rate in 2001. The estimated net savings is $5400 annually, resulting in a 1-2 year payback. It is likely that similar energy/cost savings were realized at the Callaway Gardens hotel. In this installation, however, a central plant supplied the chilled water serving fan coil units in the hotel wing retrofitted with the ADM, so it was not metered separately. Consequently, the owner could not provide actual energy consumption data specific to the facility. The energy and operating cost savings at both sites are directly attributable to higher cooling-season thermostat settings and decreased conventional system run times. These field installations were selected as an immediate and appropriate response to correct indoor humidity and fresh air ventilation problems being experienced by building occupants and owners, so no rigorous baseline-building vs. test-building energy use/operating cost savings results can be presented. The report presents several simulated comparisons between the ADM/roof HVAC approach and other equipment combinations, where both desiccant and conventional systems are modeled to provide comparable fresh air ventilation rates and indoor humidity levels. The results obtained from these simulations demonstrate convincingly the energy and operating cost savings obtainable with this hybrid desiccant/vapor-compression technology, verifying those actually seen at the pilot installations. The ADM approach is less expensive than conventional alternatives providing similar performance and indoor air quality and provides a very favorable payback (1 year or so) compared with oversized rooftop units that cannot be operated effectively with the necessary high outdoor air percentages.

  7. Importance of energy efficiency in office equipment

    SciTech Connect (OSTI)

    Blatt, M.H.

    1995-12-01T23:59:59.000Z

    Energy-Efficient Office Technology 1994: An International Seminar has been organized and funded by the Office Technology Efficiency Consortium, a group of utilities, government agencies, and other energy efficiency advocates that has been aggressively championing the need for more efficient computers, displays, printers, faxes, and copiers. The Consortium, organized in late 1992, currently consists of 10 cofunders and numerous other participants. The cofunders are: The Electric Power Research Institute, New York State Energy Research and Development Authority, Consolidated Edison Company of New York, the Swedish National Board for Industrial and Technical Development (NUTEK), Ontario Hydro, Pacific Gas and Electric Company, U.S. Department of Energy, U.S. Environmental Protection Agency, and the Wisconsin Center for Demand-Side Research. The Consortium has been striving to achieve multiple objectives. These objectives are to: (1) Improve office technology user energy efficiency end operating cost (2) Improve end-use equipment`s power quality characteristics (3) Increase equipment immunity to power line disturbances (4) Avoid the need for wiring overloads and upgrades (5) Reduce utility`s peak demand (6) Improve utility load factor. The growth in electricity use in the United States and the need for additional utility capacity has been driven to a great extent by the U.S. shift to a service economy and the coincident increase in the use of office equipment in these service establishments. The initial efforts of the Consortium, which consisted of the cofunders, included holding a workshop in June 1992 to heighten awareness of the importance of the need for more efficient office equipment. The workshop was documented in {open_quotes}Proceedings: Energy-Efficient Office Technologies,{close_quotes} TR-101945, in December 1992.

  8. Indoor Pollutants Emitted by Electronic Office Equipment

    SciTech Connect (OSTI)

    Maddalena, Randy L.; Destaillats, Hugo; Russell, Marion L.; Hodgson, Alfred T.; McKone, Thomas E.

    2008-07-01T23:59:59.000Z

    The last few decades have seen major changes in how people collect and process information at work and in their homes. More people are spending significant amounts of time in close proximity to computers, video display units, printers, fax machines and photocopiers. At the same time, efforts to improve energy efficiency in buildings by reducing leaks in building envelopes are resulting in tighter (i.e., less ventilated) indoor environments. Therefore, it is critical to understand pollutant emission rates for office equipment because even low emissions in areas that are under-ventilated or where individuals are in close proximity to the pollutant source can result in important indoor exposures. We reviewed existing literature reports on pollutant emission by office equipment, and measured emission factors of equipment with significant market share in California. We determined emission factors for a range of chemical classes including volatile and semivolatile organic compounds (VOCs and SVOCs), ozone and particulates. The measured SVOCs include phthalate esters, brominated and organophosphate flame retardants and polycyclic aromatic hydrocarbons. Measurements were carried out in large and small exposure chambers for several different categories of office equipment. Screening experiments using specific duty cycles in a large test chamber ({approx}20 m{sup 3}) allowed for the assessment of emissions for a range of pollutants. Results from the screening experiments identified pollutants and conditions that were relevant for each category of office equipment. In the second phase of the study, we used a smaller test chamber ({approx}1 m{sup 3}) to measure pollutant specific emission factors for individual devices and explored the influence of a range of environmental and operational factors on emission rates. The measured emission factors provide a data set for estimating indoor pollutant concentrations and for exploring the importance of user proximity when estimating exposure concentrations.

  9. Development and testing of a high efficiency advanced coal combustor: Phase 3 industrial boiler retrofit. Final report

    SciTech Connect (OSTI)

    Patel, R.L.; Thornock, D.E.; Miller, B.G.; Scaroni, A.W.; McGowan, J.G.

    1998-03-01T23:59:59.000Z

    Economics and/or political intervention may one day dictate the conversion from oil or natural gas to coal in boilers that were originally designed to burn oil or gas. In recognition of this future possibility the US Department of Energy, Federal Energy Technical Center (DOE-FETC) supported a program led by ABB Power Plant Laboratories with support from the Energy and Fuels Research Center of Penn State University with the goal of demonstrating the technical and economic feasibility of retrofitting a gas/oil designed boiler to burn micronized coal. In support of the overall goal the following specific objectives were targeted: develop a coal handling/preparation system that can meet the technical and operational requirements for retrofitting microfine coal on a boiler designed for burning oil or natural gas; maintain boiler thermal performance in accordance with specifications when burning oil or natural gas; maintain NOx emissions at or below 0.6 lb NO{sub 2} per million Btu; achieve combustion efficiencies of 98% or higher; and determine economic payback periods as a function of key variables.

  10. District heating and cooling systems for communities through power plant retrofit distribution network. Phase 2. Final report, 1 March 1980-31 January 1984. Volume VII. Appendix C

    SciTech Connect (OSTI)

    Not Available

    1984-01-31T23:59:59.000Z

    This volume contains: Hudson No. 2 Limited Retrofit Cost Estimates provided by Stone and Webster Engineering Corp. (SWEC); backup data and basis of estimate for SWEC Heater Plant and Gas Turbine Plant (Kearny No. 12) cost estimates; and Appendices - Analysis of Relevant Tax Laws.

  11. District heating and cooling systems for communities through power plant retrofit distribution network. Phase 2. Final report, March 1, 1980-January 31, 1984. Volume IV

    SciTech Connect (OSTI)

    Not Available

    1984-01-31T23:59:59.000Z

    This volume contains the following: discussion of cost estimating methodology, detailed cost estimates of Hudson No. 2 retrofit, intermediate thermal plant (Kearny No. 12) and local heater plants; transmission and distribution cost estimate; landfill gas cost estimate; staged development scenarios; economic evaluation; fuel use impact; air quality impact; and alternatives to district heating.

  12. In Proc. 1996 ACEEE Summer Study, August 1996, Asilomar, CA Field Measurements of Efficiency and Duct Retrofit Effectiveness in Residential Forced air

    E-Print Network [OSTI]

    consumption. These data were used to calculate distribution system delivery efficiency as well as the overall% reduction in heating energy consumption. · Cummings et al. performed pre- and post-duct retrofit. The systems in these houses included conventional air conditioning, gas furnaces, electric furnaces and heat

  13. IMPROVEMENT TO PIPELINE COMPRESSOR ENGINE RELIABILITY THROUGH RETROFIT MICRO-PILOT IGNITION SYSTEM-PHASE I

    SciTech Connect (OSTI)

    Ted Bestor

    2003-03-04T23:59:59.000Z

    This report documents the first year's effort towards a 3-year program to develop micropilot ignition systems for existing pipeline compressor engines. In essence, all Phase I goals and objectives were met. We intend to proceed with the Phase II research plan, as set forth by the applicable Research Management Plan. The objective for Phase I was to demonstrate the feasibility of micropilot ignition for large bore, slow speed engines operating at low compression ratios. The primary elements of Micropilot Phase I were to develop a single-cylinder test chamber to study the injection of pilot fuel into a combustion cylinder and to develop, install and test a multi-cylinder micropilot ignition system for a 4-cylinder, natural gas test engine. In all, there were twelve (12) tasks defined and executed to support these two (2) primarily elements in a stepwise fashion. Task-specific approaches and results are documented in this report. Research activities for Micropilot Phase I were conducted with the understanding that the efforts are expected to result in a commercial product to capture and disseminate the efficiency and environmental benefits of this new technology. An extensive state-of-art review was conducted to leverage the existing body of knowledge of micropilot ignition with respect to retrofit applications. Additionally, commercially-available fuel injection products were identified and applied to the program where appropriate. This approach will minimize the overall time-to-market requirements, while meeting performance and cost criteria. The four-cylinder prototype data was encouraging for the micro-pilot ignition technology when compared to spark ignition. Initial testing results showed: (1) Brake specific fuel consumption of natural gas was improved from standard spark ignition across the map, 1% at full load and 5% at 70% load. (2) 0% misfires for all points on micropilot ignition. Fuel savings were most likely due to this percent misfire improvement. (3) THC (Total Hydrocarbon) emissions were improved significantly at light load, 38% at 70% load. (4) VOC (Volatile Organic Compounds) emissions were improved above 80% load. (5) Coefficient of Variance for the IMEP (Indicated Mean Effective Pressure) was significantly less at lower loads, 76% less at 70%. These preliminary results will be substantiated and enhanced during Phase II of the Micropilot Ignition program.

  14. Viewing device for electron-beam equipment

    SciTech Connect (OSTI)

    Nasyrov, R.S.

    1985-06-01T23:59:59.000Z

    Viewing devices are used to observe melting, welding, and so on in vacuum systems, an it is necessary to protect the windows from droplets and vapor. A viewing device for electron-beam equipment is described in which the viewing tube and mounting flange are made as a tubular ball joint enclosed in a steel bellows, which render the viewing device flexible. Bending the viewing tube in the intervals between observations protects the viewing window from sputtering and from drops of molten metal.

  15. A lessee's guide to leasing industrial equipment

    E-Print Network [OSTI]

    Johnson, Jones Eugene

    1959-01-01T23:59:59.000Z

    is included in the agree- ment, the lessee is treading on dangerous ground, The Internal Reve- nue Service will examine such agreements closely and may decide the original transaction was a sale and not a lease. Regardless, whether the lessee actually...A LESSEE'S GUIDE TO LEASING INDUSTRIAL EQUIPMENT A Thesis Submitted to the Graduate School of the Agricultural and Mechanical College of Texas in Partial fulfillment of the requirements for the degree of Master of Business Administration...

  16. Measured Peak Equipment Loads in Laboratories

    SciTech Connect (OSTI)

    Mathew, Paul A.

    2007-09-12T23:59:59.000Z

    This technical bulletin documents measured peak equipment load data from 39 laboratory spaces in nine buildings across five institutions. The purpose of these measurements was to obtain data on the actual peak loads in laboratories, which can be used to rightsize the design of HVAC systems in new laboratories. While any given laboratory may have unique loads and other design considerations, these results may be used as a 'sanity check' for design assumptions.

  17. Improving Home Automation by Discovering Regularly Occurring Device Usage Patterns

    E-Print Network [OSTI]

    Cook, Diane J.

    Improving Home Automation by Discovering Regularly Occurring Device Usage Patterns Edwin O in an environment can be mined to discover significant patterns, which an intelligent agent could use to automate of two prediction algorithms, thus demonstrating multiple uses for a home automation system. Finally, we

  18. accident excursion occurring: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    accident excursion occurring First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Annual Report of Railroad...

  19. After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-load Equipment

    SciTech Connect (OSTI)

    Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Margaret J.; Busch, John F.

    2004-01-22T23:59:59.000Z

    This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of ''miscellaneous'' plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from twelve commercial buildings in California, Georgia, and Pennsylvania: two health care buildings, two large offices (> 500 employees each), three medium offices (50-500 employees), four education buildings, and one ''small office'' that is actually an aggregate of five small businesses. Two buildings are in the San Francisco Bay area of California, five are in Pittsburgh, Pennsylvania, and five are in Atlanta, Georgia.

  20. Equipment Selection for Surface Mining: A Review

    E-Print Network [OSTI]

    2013-07-19T23:59:59.000Z

    extract and haul mined material, including both waste and ore, over the lifetime .... tions where primary excavations occur and stockpiles where reserve material is ... with respect to period demand, productivity balancing requirements between

  1. SPRAY FOAM IN ACCESSIBLE SPACES:BEST PRACTICES AND CASE STUDIES FOR RETROFIT IN MIXED-HUMID CLIMATE

    SciTech Connect (OSTI)

    Christian, Jeffrey E [ORNL; Gant, Kathy [Oak Ridge National Laboratory (ORNL)

    2013-12-01T23:59:59.000Z

    Heating and cooling the house is one of the homeowners major expenses. Reducing these costs, saving energy, and creating a healthier, more comfortable indoor environment are good reasons to consider improving the building thermal envelope. Improvements usually consider increasing the amount of insulation, reducing the infiltration of outside air, and controlling moisture in existing buildings. This report describes the use of spray foam materials to insulate, seal, and control moisture. This discussion is limited to treating areas that are accessible. What is accessible, however, can vary depending on the type of renovation. If the building has been gutted or exterior surfaces removed, there are more options. This report will look at areas to consider for spray foam application and discuss the types of spray foams available and their uses. A number of case studies are presented to show the effectiveness of this retrofit in existing houses based on performance data.

  2. Simplified Space Conditioning in Low-Load Homes: Results from the Fresno, California, Retrofit Unoccupied Test House

    SciTech Connect (OSTI)

    Stecher, D.; Poerschke, A.

    2014-02-01T23:59:59.000Z

    Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems -- a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms -- were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

  3. RM12-2703 Advanced Rooftop Unit Control Retrofit Kit Field Demonstration: Hawaii and Guam Energy Improvement Technology Demonstration Project

    SciTech Connect (OSTI)

    Doebber, I.; Dean, J.; Dominick, J.; Holland, G.

    2014-03-01T23:59:59.000Z

    As part of its overall strategy to meet its energy goals, the Naval Facilities Engineering Command (NAVFAC) partnered with U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to rapidly demonstrate and deploy cost-effective renewable energy and energy efficiency technologies. This was one of several demonstrations of new and underutilized commercial energy efficiency technologies. The consistent year-round demand for air conditioning and dehumidification in Hawaii provides an advantageous demonstration location for advanced rooftop control (ARC) retrofit kits to packaged rooftop units (RTUs). This report summarizes the field demonstration of ARCs installed on nine RTUs serving a 70,000-ft2 exchange store (large retail) and two RTUs, each serving small office buildings located on Joint Base Pearl Harbor-Hickam (JBPHH).

  4. Exhaust-gas recirculation for retrofit NOx control on natural gas engines. Topical report, January-April 1988

    SciTech Connect (OSTI)

    Urban, C.M.

    1989-01-01T23:59:59.000Z

    Data on exhaust-gas recirculation obtained from Tenneco Gas Transportation Company were reviewed and analyzed, and a basic EGR system design and cost estimate were developed. EGR can provide practical NOx reductions of up to 50% in 2-cycle natural gas engines. The amount of NO reduction achievable is dependent on the initial baseline NOx emissions of the engine. On the basis of NOx reduction per unit of costs, EGR was found to be more cost effective than selective catalytic reduction. EGR is considered to provide a practical retrofit NOx control method in applications where the level of NOx control achievable with EGR meet regulatory requirements. One specific application is emissions offset to enable installation of additional engine horsepower. Also, EGR could become the primary NOx control method for any regulation in which costs are a major consideration.

  5. Sustainable Retrofit of Residential Roofs Using Metal Roofing Panels, Thin-Film Photovoltaic Laminates, and PCM Heat Sink Technology

    SciTech Connect (OSTI)

    Kosny, Jan [ORNL] [ORNL; Miller, William A [ORNL] [ORNL; Childs, Phillip W [ORNL] [ORNL; Biswas, Kaushik [ORNL] [ORNL

    2011-01-01T23:59:59.000Z

    During September-October 2009, research teams representing Metal Construction Association (the largest North American trade association representing metal building manufacturers, builders, and material suppliers), CertainTeed (one of the largest U.S. manufacturers of thermal insulation and building envelope materials), Unisolar (largest U.S. producer of amorphous silicone photo-voltaic (PV) laminates), Phase Change Energy (manufacturer of bio-based PCM), and Oak Ridge National Laboratory (ORNL) installed three experimental attics utilizing different roof retrofit strategies in the ORNL campus. The main goal of this project was experimental evaluation of a newly-developed sustainable re-roofing technology utilizing amorphous silicone PV laminates integrated with metal roof and PCM heat sink. The experimental attic with PV laminate was expected to work during the winter time as a passive solar collector with PCM storing solar heat, absorbed during the day, and increasing overall attic air temperature during the night.

  6. Low NO{sub x}/SO{sub x} Burner retrofit for utility cyclone boilers. Public design report

    SciTech Connect (OSTI)

    Not Available

    1991-09-01T23:59:59.000Z

    This Public Design Report provides available nonproprietary design information on the Low NO{sub x}SO{sub x} Burner Retrofit of Utility Cyclone Boilers project. In addition to the design aspects, the history of the project, the organization of the project, and the role of the funding parties are discussed. An overview of the Low NO{sub x}SO{sub x} (LNS) Burner, the cyclone boiler and the Southern Illinois Power Cooperative host site is presented. A detailed nonproprietary description of the individual process steps, plant systems, and resulting performance then follows. Narrative process descriptions, simplified process flow diagrams, input/output stream data, operating conditions and requirements are given for each unit. The plant demonstration program and start up provisions, the environmental considerations and control, monitoring and safety factors that are considered are also addressed.

  7. Simulated Energy Savings Comparison Between Two Continuous Commissioning® Methods Applied to a Retrofitted Office Building

    E-Print Network [OSTI]

    Texas A& M Campus Building CC® Team

    in the summer of 2001, the control system was set up with a prescribed sequence of operation for each piece of equipment. The multi-zone AHU was started and stopped by an associated DDC panel. Once energized, the outside air damper would open fully... to maintain zone temperatures at their set points. Deck temperature set points and zone temperature set points were constant, fixed values. The three VAV AHUs were also started and stopped by associated DDC panels. Once energized, the outside air damper...

  8. Metering and Monitoring Approaches for Verifying Energy Savings from Energy Conservation Retrofits: Experiences from the Field

    E-Print Network [OSTI]

    McBride, J. R.; Bohmer, C. J.; Lippman, R. H.

    to be amortized over more than one project. Installation labor requirements for these systems vary, but even simple installation, will require about 4-8 hours each for an electrician/field engineer team to install the monitoring equipment and verify its...-term monitoring experiments. WHTs normally cost i ' the $400-$600 range excluding CTs, and could require 2-4 hours for a field engineer/electrician I team to install and verify. One of the major variables influencing WHT installation costs is t e difficulty...

  9. Anne Arundel County- Solar and Geothermal Equipment Property Tax Credits

    Broader source: Energy.gov [DOE]

    Anne Arundel County offers a one-time credit from county property taxes on residential dwellings that use solar and geothermal energy equipment for heating and cooling, and solar energy equipment...

  10. Anne Arundel County- Solar and Geothermal Equipment Property Tax Credit

    Broader source: Energy.gov [DOE]

    This is a one-time credit from county property taxes on residential structures that use solar and geothermal energy equipment for heating and cooling and solar energy equipment for water heating...

  11. Training Room Equipment Instructions Projector and TV Display

    E-Print Network [OSTI]

    Crawford, T. Daniel

    Training Room Equipment Instructions Projector and TV Display The control panel on the wall are connected to a training room computer and room is equipped with a keyboard, mouse and clicker. Connect USB

  12. Property Tax Exemption for Machinery, Equipment, Materials, and Supplies (Kansas)

    Broader source: Energy.gov [DOE]

    The Property Tax Exemption for Machinery, Equipment, Materials, and Supplies exists for low-dollar items of machinery, equipment, materials and supplies used for business purposes, or in activities...

  13. New web page lists excess equipment | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    New web page lists excess equipment If you need a piece of equipment or office furniture, you can now go online to see if there's something at the Ames Laboratory warehouse that...

  14. Difficulty of Measuring Emissions from Heavy-Duty Engines Equipped...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Difficulty of Measuring Emissions from Heavy-Duty Engines Equipped with SCR and DPF Difficulty of Measuring Emissions from Heavy-Duty Engines Equipped with SCR and DPF In reference...

  15. Reducing variability in equipment availability at Intel using systems optimization

    E-Print Network [OSTI]

    Kwong, William W. M

    2004-01-01T23:59:59.000Z

    Equipment management is an important driver behind operational efficiency, since capital equipment makes up about 40% of the average semiconductor manufacturer's total assets. The main goal of this project is to reduce ...

  16. Sales and Use Tax Exemption for Electrical Generating Equipment

    Broader source: Energy.gov [DOE]

    Indiana does not have a specific sales and use tax exemption for equipment used in the production of renewable electricity. Therefore, such equipment is presumed to be subject to sales and use tax....

  17. Home and Farm Security Machinery and Equipment Identification. 

    E-Print Network [OSTI]

    Nelson, Gary S.

    1982-01-01T23:59:59.000Z

    73 Fibme and Farm Security -m Machinery and Equipment identification Home and Farm Security chinery and Equipment Identification *Gary S. Nelson is no longer just an urban problem. d burglaries in rural communities have to an alarming...

  18. Optimal Sequencing of Central Refrigeration Equipment in an Industrial Plant

    E-Print Network [OSTI]

    Fiorino, D. P.; Priest, J. W.

    1986-01-01T23:59:59.000Z

    A model was developed to find a viable solution to the problem of selecting the optimal sequence of refrigeration equipment (chillers, cooling towers, pumps) to operate in a Central Utility Plant. The optimal equipment sequence is that sequence...

  19. An Approach to Evaluating Equipment Efficiency Policies

    E-Print Network [OSTI]

    Newsom, D. E.; Evans, A. R.

    1980-01-01T23:59:59.000Z

    AN APPROACH TO EVALUATING EQUIPMENT EFFICIENCY POLICIES Donald E. Newsom, Ph.D. and Allan R. Evans, Ph.D., P.E. Argonne National Laboratory, Argonne, Illinois ABSTRACT The National Energy Conservation Policy Act of 1978 authorized studies... odology to be used in performing the studies. i In response to the requirements of NECPA, 4r gonne National Laboratory has been engaged in t~e development of an approach to the evaluation of!pos i sible governmental policy options that would en~our- I...

  20. Transportation Equipment (2010 MECS) | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron Spin Transition in2, 2003ToolsearchTransportation Equipment (2010 MECS)

  1. Smart Buildings Equipment Initiative | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMayDepartment of Energy Ready, Set,Buildings Equipment Initiative Smart

  2. Zhongneng Windpower Equipments | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual Siteof Energy 2,AUDITCaliforniaWeifang SwisselectronicXianEquipments Jump to: navigation,

  3. Appliances and Commercial Equipment Standards: Guidance

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office511041cloth DocumentationProductsAlternative FuelsSanta3Appliance and Equipment Standards Fact

  4. Equipment-Resources-PHaSe-EFRC

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist. Category UC-l 1, 13 DE@Energy Innovation100 tonEquipment

  5. Laboratory Equipment Donation Program - Application Process

    Office of Scientific and Technical Information (OSTI)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOnItem Not Found Item Not Found TheHot electron dynamics in807 DE89 002669 RF and^Equipment

  6. Equipment Certification Requirements | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model,DOEHazel Crest,EnergySerranopolisEnviroMissionEquipment Certification

  7. INL Equipment to Aid Regional Response Team

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cnHigh School footballHydrogen andHypernuclei in HallLeo282INL Equipment to

  8. Commercial Cooking Equipment | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualProperty EditCalifornia:PowerCER.png ElColumbia, North Carolina:Cooking Equipment Incentives

  9. Commercial Refrigeration Equipment | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualProperty EditCalifornia:PowerCER.png ElColumbia, North Carolina:Cooking Equipment

  10. Equips Nucleares SA | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualPropertyd8c-a9ae-f8521cbb8489 No revision|LLCInsulation Incentives Retrieved fromEquips

  11. Safe Operating Procedure LOCKOUT/TAGOUT FOR MACHINES & EQUIPMENT

    E-Print Network [OSTI]

    Farritor, Shane

    Safe Operating Procedure (5/11) LOCKOUT/TAGOUT FOR MACHINES & EQUIPMENT: SPECIAL CIRCUMSTANCES://ehs.unl.edu/) Introduction This SOP is intended to work in tandem with other EHS SOPs related to Lockout/Tagout (LO/TO): · Lockout/Tagout for Machines & Equipment: Program Overview · Lockout/Tagout for Machines & Equipment

  12. Mixed Oxide Fresh Fuel Package Auxiliary Equipment

    SciTech Connect (OSTI)

    Yapuncich, F.; Ross, A. [AREVA Federal Services (AFS), Tacoma WA (United States); Clark, R.H. [Shaw AREVA MOX Services, Savannah River Site, Aiken, SC (United States); Ammerman, D. [Sandia National Laboratories, Albuquerque, NM (United States)

    2008-07-01T23:59:59.000Z

    The United States Department of Energy's National Nuclear Security Administration (NNSA) is overseeing the construction the Mixed Oxide (MOX) Fuel Fabrication Facility (MFFF) on the Savannah River Site. The new facility, being constructed by NNSA's contractor Shaw AREVA MOX Services, will fabricate fuel assemblies utilizing surplus plutonium as feedstock. The fuel will be used in designated commercial nuclear reactors. The MOX Fresh Fuel Package (MFFP), which has recently been licensed by the Nuclear Regulatory Commission (NRC) as a type B package (USA/9295/B(U)F-96), will be utilized to transport the fabricated fuel assemblies from the MFFF to the nuclear reactors. It was necessary to develop auxiliary equipment that would be able to efficiently handle the high precision fuel assemblies. Also, the physical constraints of the MFFF and the nuclear power plants require that the equipment be capable of loading and unloading the fuel assemblies both vertically and horizontally. The ability to reconfigure the load/unload evolution builds in a large degree of flexibility for the MFFP for the handling of many types of both fuel and non fuel payloads. The design and analysis met various technical specifications including dynamic and static seismic criteria. The fabrication was completed by three major fabrication facilities within the United States. The testing was conducted by Sandia National Laboratories. The unique design specifications and successful testing sequences will be discussed. (authors)

  13. Naturally occurring crystalline phases: analogues for radioactive waste forms

    SciTech Connect (OSTI)

    Haaker, R.F.; Ewing, R.C.

    1981-01-01T23:59:59.000Z

    Naturally occurring mineral analogues to crystalline phases that are constituents of crystalline radioactive waste forms provide a basis for comparison by which the long-term stability of these phases may be estimated. The crystal structures and the crystal chemistry of the following natural analogues are presented: baddeleyite, hematite, nepheline; pollucite, scheelite;sodalite, spinel, apatite, monazite, uraninite, hollandite-priderite, perovskite, and zirconolite. For each phase in geochemistry, occurrence, alteration and radiation effects are described. A selected bibliography for each phase is included.

  14. Radioactive Mineral Occurences in Nevada | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere I GeothermalPotentialBiopowerSolidGenerationMethodInformationeNevadaRadioactive Mineral Occurences in

  15. Space and Movable Equipment Inventory Revision: July 31, 2014 CERTIFICATION OF SPACE AND MOVABLE EQUIPMENT INVENTORY -FISCAL YEAR 2014

    E-Print Network [OSTI]

    Hayden, Nancy J.

    Space and Movable Equipment Inventory Revision: July 31, 2014 CERTIFICATION OF SPACE AND MOVABLE EQUIPMENT INVENTORY - FISCAL YEAR 2014 TO BE USED FOR IBB PLANNING FOR FISCAL YEAR 2016 I acknowledge that the space and movable equipment inventory results conducted for this fiscal year will be used for IBB

  16. Naturally Occurring Radioactive Materials in Cargo at US Borders

    SciTech Connect (OSTI)

    Kouzes, Richard T.; Ely, James H.; Evans, John C.; Hensley, Walter K.; Lepel, Elwood A.; McDonald, Joseph C.; Schweppe, John E.; Siciliano, Edward R.; Strom, Daniel J.; Woodring, Mitchell L.

    2006-01-01T23:59:59.000Z

    In the U.S. and other countries, large numbers of vehicles pass through border crossings each day. The illicit movement of radioactive sources is a concern that has resulted in the installation of radiation detection and identification instruments at border crossing points. This activity is judged to be necessary because of the possibility of an act of terrorism involving a radioactive source that may include any number of dangerous radionuclides. The problem of detecting, identifying, and interdicting illicit radioactive sources is complicated by the fact that many materials present in cargo are somewhat radioactive. Some cargo contains naturally occurring radioactive material or technologically-enhanced naturally occurring radioactive material that may trigger radiation portal monitor alarms. Man-made radioactive sources, especially medical isotopes, are also frequently observed and produce alarms. Such nuisance alarms can be an operational limiting factor for screening of cargo at border crossings. Information about the nature of the radioactive materials in cargo that can interfere with the detection of radionuclides of concern is necessary. This paper provides such information for North American cargo, but the information may also be of use to border control officials in other countries. (PIET-43741-TM-361)

  17. Emergency sacrificial sealing method in filters, equipment, or systems

    DOE Patents [OSTI]

    Brown, Erik P

    2014-09-30T23:59:59.000Z

    A system seals a filter or equipment component to a base and will continue to seal the filter or equipment component to the base in the event of hot air or fire. The system includes a first sealing material between the filter or equipment component and the base; and a second sealing material between the filter or equipment component and the base and proximate the first sealing material. The first sealing material and the second seal material are positioned relative to each other and relative to the filter or equipment component and the base to seal the filter or equipment component to the base and upon the event of fire the second sealing material will be activated and expand to continue to seal the filter or equipment component to the base in the event of hot air or fire.

  18. Resolutions of Problems that Occurred in SPEAR3 Magnet Production

    SciTech Connect (OSTI)

    Li, Nanyang

    2005-05-27T23:59:59.000Z

    Some problems occurred during the SPEAR3 magnet production at IHEP, China. It was very hard to find resolution from existing knowledge of those problems. It was possible that similar problems might have happen in building accelerator magnet in other institutes before, but they were not addressed in public papers. These problems were discussed and solved by engineers from both SLAC and IHEP after conducting certain experiments. Traditionally, the magnet design and measurement data have been always well documented and addressed in papers, but the production experiences have not been recorded adequately. It is the goal of this paper to record the problems and their resolutions during SPEAR3 magnet production at IHEP China, which will certainly benefit future magnet projects.

  19. Tenneco upgrades system with equipment conversion

    SciTech Connect (OSTI)

    Wright, K. [Ariel Corp., Mt. Vernon, OH (United States)

    1995-10-01T23:59:59.000Z

    Tenneco Gas, Inc., Houston, recently completed the successful conversion of over 14,300 horsepower compression equipment at its transmission in Catlettsburg, KY. The system consists of three identical Ariel JGC/6 compressors, driven by three matching Ansaldo electric motors, capable of running between 450 and 900 rpm. These variable speed, synchronous electric motors allow for greater flexibility, without the use of traditional cylinder unloaders. If desired Eureka Energy Systems, Richardson, TX designed the compressor package. One of Tenneco`s objectives when selecting a package to upgrade existing compression capabilities was to ensure compliance with future regulations promulgated pursuant to the Clean Air Act Amendments of 1990. Initially, Tenneco considered separable compressors because of the availability of the newer, clean burning, gas ignited drivers in the 5,000 horsepower range, such as the Caterpillar 3612 and 3616. This paper reviews the design, performance and comparative operating cost of these compressor units.

  20. Development of an automated methodology for calibration of simplified air-side HVAC system models and estimation of potential savings from retrofit/commissioning measures

    E-Print Network [OSTI]

    Baltazar Cervantes, Juan Carlos

    2007-04-25T23:59:59.000Z

    Studies of Texas A&M University in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY Approved by: Chair of Committee, David E. Claridge Committee Members, Charles H. Culp Jeff W. Dan Turner Head... Retrofit/Commissioning Measures. (December 2006) Juan Carlos Baltazar Cervantes, B.S., University of Guanajuato, M?xico; M.S., University of Guanajuato, M?xico; M.S., Texas A&M University Chair of Advisory Committee: Dr. David E. Claridge...