Sample records for responding voltage regulator

  1. Temperature controlled high voltage regulator

    DOE Patents [OSTI]

    Chiaro, Jr., Peter J. (Clinton, TN); Schulze, Gerald K. (Knoxville, TN)

    2004-04-20T23:59:59.000Z

    A temperature controlled high voltage regulator for automatically adjusting the high voltage applied to a radiation detector is described. The regulator is a solid state device that is independent of the attached radiation detector, enabling the regulator to be used by various models of radiation detectors, such as gas flow proportional radiation detectors.

  2. Dynamic Voltage Regulation Using Distributed Energy Resources

    SciTech Connect (OSTI)

    Xu, Yan [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Kueck, John D [ORNL

    2007-01-01T23:59:59.000Z

    Many distributed energy resources (DE) are near load centres and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide ancillary services such as voltage regulation, nonactive power compensation, and power factor correction. A synchronous condenser and a microturbine with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Voltage control schemes of the inverter and the synchronous condenser are developed. The experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously, while the dynamic response of the inverter is faster than the synchronous condenser; and that integrated voltage regulation (multiple DE perform voltage regulation) can increase the voltage regulation capability, increase the lifetime of the equipment, and reduce the capital and operation costs.

  3. Voltage regulation in linear induction accelerators

    DOE Patents [OSTI]

    Parsons, William M. (Santa Fe, NM)

    1992-01-01T23:59:59.000Z

    Improvement in voltage regulation in a Linear Induction Accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance.

  4. Voltage regulation in linear induction accelerators

    DOE Patents [OSTI]

    Parsons, W.M.

    1992-12-29T23:59:59.000Z

    Improvement in voltage regulation in a linear induction accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core is disclosed. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance. 4 figs.

  5. automatic regulator voltage: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Rouzbahan 2013-01-01 12 Optimal Distributed Voltage Regulation in Power Distribution Networks CERN Preprints Summary: In this paper, we address the problem of voltage...

  6. DIII-D ICRF high voltage power supply regulator upgrade

    SciTech Connect (OSTI)

    Cary, W.P.; Burley, B.L.; Grosnickle, W.H.

    1997-11-01T23:59:59.000Z

    For reliable operation and component protection, of the 2 MW 30--120 MHz ICRF Amplifier System on DIII-D, it is desirable for the amplifier to respond to high VSWR conditions as rapidly as possible. This requires a rapid change in power which also means a rapid change in the high voltage power supply current demands. An analysis of the power supply`s regulator dynamics was needed to verify its expected operation during such conditions. Based on this information it was found that a new regulator with a larger dynamic range and some anticipation capability would be required. This paper will discuss the system requirements, the as-delivered regulator performance, and the improved performance after installation of the new regulator system. It will also be shown how this improvement has made the amplifier perform at higher power levels more reliably.

  7. Distribution System Voltage Regulation by Distributed Energy Resources

    SciTech Connect (OSTI)

    Ceylan, Oguzhan [ORNL; Liu, Guodong [ORNL; Xu, Yan [ORNL; Tomsovic, Kevin [University of Tennessee, Knoxville (UTK)

    2014-01-01T23:59:59.000Z

    This paper proposes a control method to regulate voltages in 3 phase unbalanced electrical distribution systems. A constrained optimization problem to minimize voltage deviations and maximize distributed energy resource (DER) active power output is solved by harmony search algorithm. IEEE 13 Bus Distribution Test System was modified to test three different cases: a) only voltage regulator controlled system b) only DER controlled system and c) both voltage regulator and DER controlled system. The simulation results show that systems with both voltage regulators and DER control provide better voltage profile.

  8. Operation of buck regulator with ultra-low input voltage

    E-Print Network [OSTI]

    Harris, Cory Angelo

    2014-01-01T23:59:59.000Z

    Based on the LTC3621 and LTC3624, the designed buck regulator proposed in this thesis aims to lower the allowed input voltage and increase efficiency compared to the original part without making significant changes to ...

  9. Stability issues in IC Low Drop Out voltage regulators

    E-Print Network [OSTI]

    Chava, Krishna Chaitanya

    2002-01-01T23:59:59.000Z

    Performance issues of IC Low Drop Out (LDO) voltage regulators, with specific reference to stability, are discussed in this thesis. Evaluation of existing frequency compensation schemes and their performances across operating loads is presented...

  10. High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    DOE Patents [OSTI]

    Shimer, D.W.; Lange, A.C.

    1995-05-23T23:59:59.000Z

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

  11. High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    DOE Patents [OSTI]

    Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

    1995-01-01T23:59:59.000Z

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

  12. Experiment and Simulation of Dynamic Voltage Regulation in Multiple Distributed Energy Resources Systems

    SciTech Connect (OSTI)

    Xu, Yan [ORNL; Li, Fangxing [ORNL; Kueck, John D [ORNL; Rizy, D Tom [ORNL

    2007-01-01T23:59:59.000Z

    Distributed energy (DE) resources are power sources located near load centers and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide reactive power (along with active power) locally for dynamic voltage regulation. In this paper, a synchronous condenser and a microturbine with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Developed voltage control schemes for the inverter and the synchronous condenser are presented. Experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously although the dynamic response of the inverter is much faster than the synchronous condenser. In a system with multiple DEs performing local voltage regulation, the interaction between the DEs is studied. The simulation results show the relationship between the voltages in the system and the reactive power required for the voltage regulation. Also, integrated voltage regulation (multiple DEs performing voltage regulation) can increase the voltage regulation capability of DEs and reduce the capital and operating costs.

  13. PVREG - A photovoltaic voltage regulation investigation tool: Program reference manual

    SciTech Connect (OSTI)

    Garrett, D.L.; Sims, T.R.; Jones, R.A.; Jeter, S.M.

    1989-06-01T23:59:59.000Z

    This manual provides information for installing and maintaining the computer program PVREG, a program developed to study the impact of distributed photovoltaic systems on the voltage regulation of distribution systems. The manual describes installation on the Apollo workstation or the IBM PC-AT (or compatible), but the instructions and code description should be general enough to assist installation on other computers, also. The manual assumes that the user is well acquainted with the computer on which the program is to operate and with the operating system of that computer. The manual describes the program structure and models in detail and provides step-by-step installation instructions for both the Apollo and AT-compatible computers. 9 figs., 11 tabs.

  14. A SCR SWITCHED CAPACITOR VOLTAGE REGULATOR FOR 150 kV NEUTRAL BEAM POWER SUPPLY

    E-Print Network [OSTI]

    Milnes, K.A.

    2011-01-01T23:59:59.000Z

    et a1. , "150-kV, 80-A Solid State Power Supply for Neutral100% solid state and provides 1% regulation at power levelssolid state high voltage re- gulator. The block diagram of the power

  15. The design of an A-C voltage regulator using a Wein Bridge detector

    E-Print Network [OSTI]

    Brown, Richard True

    1959-01-01T23:59:59.000Z

    ) the regulator would correct for changes in input voltage only, as the detector ie on the input side of the controller. In Figures 1(c) and 1(d) the xegulator would corxect fox' changes in input or load conditions as the detector is placed directly across... the load. Em D Figure 1; Four types of regulator connections. The connections shown in Figures 1(b) and l(d) are limited in that the output is usually less than the input voltage, whereas in Figures 1(a) and 1(c) the controller voltage can buck...

  16. Power Management Unit A digitalized Embedded Linear Voltage Regulator for

    E-Print Network [OSTI]

    Wichmann, Felix

    Climate Control Cooling FAN Park Distance Control Adaptive Cruise Control Night Vision Blindspot Detection cost More expensive mask cost More sensitive to radiation Higher leakage current Lower voltage headroom) System CostsSystem Costs Si-Area, Test Time, Package (# of pins) Development Cost/ Time to market

  17. PEV-Based Combined Frequency and Voltage Regulation for Smart Grid

    E-Print Network [OSTI]

    Huang, Jianwei

    by either adjusting supply or changing demand. While various demand side management programs have used benefit both users and utilities. Index Terms--Smart grid, plug-in electric vehicles, demand side management, reactive power compensation, ancillary ser- vices, frequency regulation, voltage regulation

  18. Modeling and Verification of Distributed Generation and Voltage Regulation Equipment for Unbalanced Distribution Power Systems; Annual Subcontract Report, June 2007

    SciTech Connect (OSTI)

    Davis, M. W.; Broadwater, R.; Hambrick, J.

    2007-07-01T23:59:59.000Z

    This report summarizes the development of models for distributed generation and distribution circuit voltage regulation equipment for unbalanced power systems and their verification through actual field measurements.

  19. Method for improving voltage regulation of batteries, particularly Li/FeS.sub.2 thermal batteries

    DOE Patents [OSTI]

    Godshall, Ned A. (Albuquerque, NM)

    1988-01-01T23:59:59.000Z

    Batteries are improved, especially with respect to voltage regulation properties, by employing as anode and cathode compositions, those which fall in a thermodynamically invariant region of the metallurgical phase diagram of the combination of the constituent components. The invention is especially useful in the Li/FeS.sub.2 system.

  20. Method for improving voltage regulation of batteries, particularly Li/FeS/sub 2/ thermal batteries

    DOE Patents [OSTI]

    Godshall, N.A.

    1986-06-10T23:59:59.000Z

    Batteries are improved, especially with respect to voltage regulation properties, by employing as anode and cathode compositions, those which fall in a thermodynamically invariant region of the metallurgical phase diagram of the combination of the constituent components. The invention is especially useful in the Li/FeS/sub 2/ system.

  1. Excitation control for improving transient stability limit and voltage regulation with dynamic loads

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    on the complex nonlinear simulation and the others are based on the linearised power system model. Although control techniques in power systems as one of the most promising application areas; see Bevrani and Hiyama to improve the power system transient stability and voltage regulation in interconnected power systems

  2. Power Deregulation: Eliminating Off-Chip Voltage Regulation Circuitry From Embedded Systems

    E-Print Network [OSTI]

    Joseph, Russ

    Power Deregulation: Eliminating Off-Chip Voltage Regulation Circuitry From Embedded Systems analytical techniques, power models, and detailed full-system simulation of numerous benchmarks from.northwestern.edu ABSTRACT In battery-powered embedded systems, dedicated circuitry is used to convert stored energy

  3. IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. XX, NO. Y, MONTH 2001 1 Global Transient Stability and Voltage Regulation

    E-Print Network [OSTI]

    Guo, Yi

    and voltage regulator. The designed controller is smooth and robust with respect to di#11;erent transient and voltage regulation are both important properties of power system control, but they are ascribed to di#11 of system behavior. We design in this paper a global controller to co-ordinate the transient stabilizer

  4. Nobody but You: Sensor Selection for Voltage Regulation in Smart Grid

    E-Print Network [OSTI]

    Mao, Rukun

    2011-01-01T23:59:59.000Z

    The increasing availability of distributed energy resources (DERs) and sensors in smart grid, as well as overlaying communication network, provides substantial potential benefits for improving the power system's reliability. In this paper, the problem of sensor selection is studied for the MAC layer design of wireless sensor networks for regulating the voltages in smart grid. The framework of hybrid dynamical system is proposed, using Kalman filter for voltage state estimation and LQR feedback control for voltage adjustment. The approach to obtain the optimal sensor selection sequence is studied. A sub- optimal sequence is obtained by applying the sliding window algorithm. Simulation results show that the proposed sensor selection strategy achieves a 40% performance gain over the baseline algorithm of the round-robin sensor polling.

  5. A Capacitor-Less Wide-Band Power Supply Rejection Low Drop-Out Voltage Regulator with Capacitance Multiplier

    E-Print Network [OSTI]

    Wang, Mengde

    2014-05-22T23:59:59.000Z

    A Low Drop-Out (LDO) voltage regulator with both capacitor-less and high power supply rejection (PSR) bandwidth attributes is highly admired for an integrated power management system of mobile electronics. The capacitor-less feature is demanded...

  6. Halbach array generator/motor having an automatically regulated output voltage and mechanical power output

    DOE Patents [OSTI]

    Post, Richard F.

    2005-02-22T23:59:59.000Z

    A motor/generator having its stationary portion, i.e., the stator, positioned concentrically within its rotatable element, i.e., the rotor, along its axis of rotation. The rotor includes a Halbach array. The stator windings are switched or commutated to provide a DC motor/generator much the same as in a conventional DC motor/generator. The voltage and power are automatically regulated by using centrifugal force to change the diameter of the rotor, and thereby vary the radial gap in between the stator and the rotating Halbach array, as a function of the angular velocity of the rotor.

  7. Precision voltage regulation on the 5 kHz, 3. 125 MW ETA-II pulsed power system

    SciTech Connect (OSTI)

    Watson, J.A.; Payne, A.N.; Sampayan, S.E.; Ollis, C.W.

    1991-06-01T23:59:59.000Z

    Each of four pulsed power units (PPUs) for the Experimental Test Accelerator 2 (ETA-2) at Lawrence Livermore National Laboratory delivers a 25kV, 20kA, 4{mu}S pulse at a 5kHz repetition rate into a magnetic pulse compression modulator (MAG-1D). In our present configuration, we are capable of producing a 50 pulse burst using a 1000{mu}F capacitor bank. In this configuration, the input voltage to the PPU droops 22% during the burst. Accelerator operating requirements, however, dictate {plus minus}0.1% regulation of the PPU output voltage during the burst. We are employing a de-Qing network to achieve this regulation goal. In this paper, we describe an output voltage predict-ahead scheme that we are using to generate de-Q trigger pulses at the proper time to insure accurate regulations. 8 refs., 5 figs.

  8. A three-level buck converter to regulate a high-voltage DC-to-AC inverter

    E-Print Network [OSTI]

    Schrock, Kenneth C

    2008-01-01T23:59:59.000Z

    A three-level buck converter is designed and analyzed, and shown to be suitable as a high-voltage down converter as a pre-regulation stage for a 600 watt DC-to-AC power inverter. Topology selection for the inverter is ...

  9. Harmonic control of multiple-stator induction machines for voltage regulation

    E-Print Network [OSTI]

    Holloway, Jack Wade, 1980-

    2004-01-01T23:59:59.000Z

    Small, one to a few horsepower, three-phase induction machines with three sets of electrically-isolated, magnetically-coupled stator winding circuits are described. A voltage inverter is developed and used to drive one set ...

  10. Voltage/Pitch Control for Maximization and Regulation of Active/Reactive Powers in Wind Turbines with Uncertainties

    E-Print Network [OSTI]

    Guo, Yi; Jiang, John N; Tang, Choon Yik; Ramakumar, Rama G

    2010-01-01T23:59:59.000Z

    This paper addresses the problem of controlling a variable-speed wind turbine with a Doubly Fed Induction Generator (DFIG), modeled as an electromechanically-coupled nonlinear system with rotor voltages and blade pitch angle as its inputs, active and reactive powers as its outputs, and most of the aerodynamic and mechanical parameters as its uncertainties. Using a blend of linear and nonlinear control strategies (including feedback linearization, pole placement, uncertainty estimation, and gradient-based potential function minimization) as well as time-scale separation in the dynamics, we develop a controller that is capable of maximizing the active power in the Maximum Power Tracking (MPT) mode, regulating the active power in the Power Regulation (PR) mode, seamlessly switching between the two modes, and simultaneously adjusting the reactive power to achieve a desired power factor. The controller consists of four cascaded components, uses realistic feedback signals, and operates without knowledge of the C_p-...

  11. Power Supply Rejection Improvement Techniques In Low Drop-Out Voltage Regulators

    E-Print Network [OSTI]

    Ganta, Saikrishna

    2011-10-21T23:59:59.000Z

    , the conventional LDOs have poor PSR at high frequencies. The objective of this research is to develop novel LDO regulators that can achieve good high frequency PSR performance. In this thesis, two PSR improvement methods are presented. The first method proposes a...

  12. IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 23, NO. 1, JANUARY 2008 495 Adaptive Modulation Control for Multiple-Phase Voltage Regulators

    E-Print Network [OSTI]

    Wu, Shin-Tson

    ) Interleaved operation waveforms. (b) Bode plot of power stage. For some advanced control schemes like adaptiveIEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 23, NO. 1, JANUARY 2008 495 Adaptive Modulation Control for Multiple-Phase Voltage Regulators Shangyang Xiao, Weihong Qiu, Greg Miller, Thomas X. Wu

  13. High voltage DC power supply

    DOE Patents [OSTI]

    Droege, Thomas F. (Batavia, IL)

    1989-01-01T23:59:59.000Z

    A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

  14. High voltage DC power supply

    DOE Patents [OSTI]

    Droege, T.F.

    1989-12-19T23:59:59.000Z

    A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

  15. A Noise-Shaped Switched-Capacitor DC-DC Voltage Regulator A. Rao, W.McIntyre 1

    E-Print Network [OSTI]

    Moon, Un-Ku

    -dc converter with fractional gains. The charge pump used to convert the input voltage acts as a D/A converter the inductive conversion topology has been the standard solution to providing a constant and stable voltage from a battery. With the continued shrinking of the hand-held devices as cell phones, PDA's, pagers and laptops

  16. Regulation of N-type Voltage-Gated Calcium Channels and Presynaptic Function by Cyclin-Dependent Kinase 5

    E-Print Network [OSTI]

    Su, Susan C.

    N-type voltage-gated calcium channels localize to presynaptic nerve terminals and mediate key events including synaptogenesis and neurotransmission. While several kinases have been implicated in the modulation of calcium ...

  17. Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics

    SciTech Connect (OSTI)

    Liu, E.; Bebic, J.

    2008-02-01T23:59:59.000Z

    This report examines the performance of commonly used distribution voltage regulation methods under reverse power flow.

  18. Charge regulation circuit

    DOE Patents [OSTI]

    Ball, Don G. (Livermore, CA)

    1992-01-01T23:59:59.000Z

    A charge regulation circuit provides regulation of an unregulated voltage supply in the range of 0.01%. The charge regulation circuit is utilized in a preferred embodiment in providing regulated voltage for controlling the operation of a laser.

  19. Saving Megawatts with Voltage Optimization

    E-Print Network [OSTI]

    Wilson, T.; Bell, D.

    2010-01-01T23:59:59.000Z

    that had been installed at several electric utility distribution substations in the U.S. and Canada. These systems, being operated in Conservation Voltage Regulation mode, have provided significant energy conservation where they have been installed...

  20. Responds to Hurricane Sandy

    E-Print Network [OSTI]

    US Army Corps of Engineers

    Army Corps Responds to Hurricane Sandy January Edition 2013 U.S. Army Corps of Engineers, New York 1 Table of Contents Page 2 Commander's Reflections Page 3 Hurricane Sandy batters NY District's AOR Contingency Plan into action for first time on Long Island Page 14 Corps personnel assist Hurricane Sandy

  1. Modular high voltage power supply for chemical analysis

    DOE Patents [OSTI]

    Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

    2010-05-04T23:59:59.000Z

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  2. Modular high voltage power supply for chemical analysis

    SciTech Connect (OSTI)

    Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

    2007-01-09T23:59:59.000Z

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC--DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC--DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  3. Modular high voltage power supply for chemical analysis

    SciTech Connect (OSTI)

    Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

    2008-07-15T23:59:59.000Z

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  4. Electronic circuit for measuring series connected electrochemical cell voltages

    DOE Patents [OSTI]

    Ashtiani, Cyrus N. (West Bloomfield, MI); Stuart, Thomas A. (Toledo, OH)

    2000-01-01T23:59:59.000Z

    An electronic circuit for measuring voltage signals in an energy storage device is disclosed. The electronic circuit includes a plurality of energy storage cells forming the energy storage device. A voltage divider circuit is connected to at least one of the energy storage cells. A current regulating circuit is provided for regulating the current through the voltage divider circuit. A voltage measurement node is associated with the voltage divider circuit for producing a voltage signal which is proportional to the voltage across the energy storage cell.

  5. Simplified VO M&V Protocol Simplified Voltage Optimization (VO)

    E-Print Network [OSTI]

    of all distribution lines that are controlled by a tap changing source voltage regulator. Several voltage-control primary system with source voltage regulation. Minimum system stability thresholds, system data modeling is mentioned, it refers to using industry accepted distribution system power flow simulation tools

  6. Training For Radiation Emergencies, First Responder Operations...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Training For Radiation Emergencies, First Responder Operations - Instructors Guide Training For Radiation Emergencies, First Responder Operations - Instructors Guide COURSE...

  7. Ancillary service details: Voltage control

    SciTech Connect (OSTI)

    Kirby, B.; Hirst, E.

    1997-12-01T23:59:59.000Z

    Voltage control is accomplished by managing reactive power on an alternating-current power system. Reactive power can be produced and absorbed by both generation and transmission equipment. Reactive-power devices differ substantially in the magnitude and speed of response and in their capital costs. System operators, transmission owners, generators, customers, power marketers, and government regulators need to pay close attention to voltage control as they restructure the U.S. electricity industry. Voltage control can affect reliability and commerce in three ways: (1) Voltages must be maintained within an acceptable range for both customer and power-system equipment to function properly. (2) The movement of reactive power consumes transmission resources, which limits the ability to move real power and worsens congestion. (3) The movement of reactive power results in real-power losses. When generators are required to supply excessive amounts of reactive power, their real-power production must be curtailed. These opportunity costs are not currently compensated for in most regions. Current tariffs are based on embedded costs. These embedded-cost tariffs average about $0.51/MWh, equivalent to $1.5 billion annually for the United States as a whole. Although this cost is low when compared with the cost of energy, it still aggregates to a significant amount of money. This report takes a basic look at why the power system requires reactive power (an appendix explains the fundamentals of real and reactive power). The report then examines the various types of generation and transmission resources used to supply reactive power and to control voltage. Finally it discusses how these resources are deployed and paid for in several reliability regions around the country. As the U.S. electricity industry is restructured, the generation, transmission, and system-control equipment and functions that maintain voltages within the appropriate ranges are being deintegrated.

  8. Constant voltage electro-slag remelting control

    DOE Patents [OSTI]

    Schlienger, M.E.

    1996-10-22T23:59:59.000Z

    A system for controlling electrode gap in an electro-slag remelt furnace has a constant regulated voltage and an electrode which is fed into the slag pool at a constant rate. The impedance of the circuit through the slag pool is directly proportional to the gap distance. Because of the constant voltage, the system current changes are inversely proportional to changes in gap. This negative feedback causes the gap to remain stable. 1 fig.

  9. High Voltage Safety Act

    Broader source: Energy.gov [DOE]

    The purpose of the High Voltage Safety Act is to prevent injury to persons and property and interruptions of utility service resulting from accidental or inadvertent contact with high-voltage...

  10. Automatic voltage imbalance detector

    DOE Patents [OSTI]

    Bobbett, Ronald E. (Los Alamos, NM); McCormick, J. Byron (Los Alamos, NM); Kerwin, William J. (Tucson, AZ)

    1984-01-01T23:59:59.000Z

    A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

  11. A Vernier Regulator for ILC Marx Droop Compensation

    SciTech Connect (OSTI)

    Tang, Tao

    2009-10-30T23:59:59.000Z

    A two-part compensation scheme, Vernier Regulation, has been applied to offset the voltage droop (40% without correction) in a Marx-topology klystron modulator developed for the International Linear Collider (ILC). Coarse regulation, {+-}5%, is achieved by turning on additional Main Marx cells (Delayed Cells) sequentially as the droop reaches the cell voltage (11 kV). Further regulation to {+-}0.5% is achieved by adding a small Marx in series with the Main Marx. This Vernier Marx is composed of sixteen, 1.2 kV cells that are assembled as a seventeenth cell in the Main Marx. These Vernier Cells are turned on sequentially to generate a series of discrete corrections to the droop in the Main Marx cells with a step size {le}1% of the output voltage. As the required correction reaches 11 kV, all Vernier Cells are turned off synchronously with the turn on of a Delayed Cell. There are up to five Delayed Cells and six Vernier Marx cycles during each ILC Marx output pulse. The Vernier Marx has a local control system that will detect and respond to over-voltage and over-current errors. In this paper, a detailed description of the design, implementation and testing of the Vernier Marx is presented.

  12. Biodetection Technologies for First Responders

    SciTech Connect (OSTI)

    Baird, Cheryl L.; Seiner, Derrick R.; Ozanich, Richard M.; Bartholomew, Rachel A.; Colburn, Heather A.; Straub, Tim M.; Bruckner-Lea, Cindy J.

    2012-10-24T23:59:59.000Z

    In a white powder scenario, there are a large number of field-deployable assays that can be used to determine if the suspicious substance contains biological material and warrants further investigation. This report summarizes commercially available technologies that are considered hand portable and can be used by first responders in the field. This is not meant to be an exhaustive list, nor do the authors endorse any of the technologies described herein. Rather, it is meant to provide useful information about available technologies to help end-users make informed decisions about biodetection technology procurement and use.

  13. LANL responds to radiological incident

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated Codes |Is Your Home as ReadyAppointedKyungmin2010 topLANL responds to

  14. Optical voltage reference

    DOE Patents [OSTI]

    Rankin, R.; Kotter, D.

    1994-04-26T23:59:59.000Z

    An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

  15. Voltage Control Technical Conference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Intro Voltage Control Conference - BPA Active Power Control in Wind Parks - Siemens Interconnection Criteria for Frequency Response Requirements - NERC Model Validation...

  16. Voltage verification unit

    DOE Patents [OSTI]

    Martin, Edward J. (Virginia Beach, VA)

    2008-01-15T23:59:59.000Z

    A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.

  17. Post regulation circuit with energy storage

    DOE Patents [OSTI]

    Ball, Don G. (Livermore, CA); Birx, Daniel L. (Oakley, CA); Cook, Edward G. (Livermore, CA)

    1992-01-01T23:59:59.000Z

    A charge regulation circuit provides regulation of an unregulated voltage supply and provides energy storage. The charge regulation circuit according to the present invention provides energy storage without unnecessary dissipation of energy through a resistor as in prior art approaches.

  18. Voltage balanced multilevel voltage source converter system

    DOE Patents [OSTI]

    Peng, F.Z.; Lai, J.S.

    1997-07-01T23:59:59.000Z

    Disclosed is a voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means. 15 figs.

  19. E-beam high voltage switching power supply

    DOE Patents [OSTI]

    Shimer, D.W.; Lange, A.C.

    1996-10-15T23:59:59.000Z

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 figs.

  20. E-beam high voltage switching power supply

    DOE Patents [OSTI]

    Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

    1996-01-01T23:59:59.000Z

    A high-power power supply produces a controllable, constant high voltage put under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

  1. First Responders | National Nuclear Security Administration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Responders | National Nuclear Security Administration Facebook Twitter Youtube Flickr RSS People Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy...

  2. responding to emergencies | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    by the Department of Homeland Security (DHS) and state and local agencies to respond Accident Response Group NNSA's Accident Response Group (ARG) provides technical guidance and...

  3. ABBGroup-1-High voltage lab

    E-Print Network [OSTI]

    Basse, Nils Plesner

    oscillations are due to travelling waves in the heating volume. #12;©ABBGroup-9- 3-Sep-07 2. High voltage phase interrupts the injected current, it is stressed by the transient recovery voltage (TRV) oscillating©ABBGroup-1- 3-Sep-07 High voltage lab Research on high voltage gas circuit breakers Nils P. Basse

  4. Electron launching voltage monitor

    DOE Patents [OSTI]

    Mendel, C.W.; Savage, M.E.

    1992-03-17T23:59:59.000Z

    An electron launching voltage monitor measures MITL voltage using a relationship between anode electric field and electron current launched from a cathode-mounted perturbation. An electron launching probe extends through and is spaced from the edge of an opening in a first MITL conductor, one end of the launching probe being in the gap between the MITL conductor, the other end being adjacent a first side of the first conductor away from the second conductor. A housing surrounds the launching probe and electrically connects the first side of the first conductor to the other end of the launching probe. A detector detects the current passing through the housing to the launching probe, the detected current being representative of the voltage between the conductors. 5 figs.

  5. Threshold voltage extraction circuit

    E-Print Network [OSTI]

    Hoon, Siew Kuok

    2000-01-01T23:59:59.000Z

    to that of the saturation method. However, instead of fixing Vos ? Vos, the drain current is measured as a function of Vos while Vns is fixed at a constant low voltage of 100mV to ensure operation in the linear MOSFET region. Neglecting channel length modulation effect... transistors are layout next to the DUT of the NMOS and PMOS Vr extraction circuits respectively for extraction of Vr via graphical means. GRAPHICAL METHOD OF THE THRESHOLD-VOLTAGE MEASUREMENT Using the graphical method, the characteristics of 4n versus Vos...

  6. Criticality Safety Basics for INL Emergency Responders

    SciTech Connect (OSTI)

    Valerie L. Putman

    2012-08-01T23:59:59.000Z

    This document is a modular self-study guide about criticality safety principles for Idaho National Laboratory emergency responders. This guide provides basic criticality safety information for people who, in response to an emergency, might enter an area that contains much fissionable (or fissile) material. The information should help responders understand unique factors that might be important in responding to a criticality accident or in preventing a criticality accident while responding to a different emergency.

    This study guide specifically supplements web-based training for firefighters (0INL1226) and includes information for other Idaho National Laboratory first responders. However, the guide audience also includes other first responders such as radiological control personnel.

    For interested readers, this guide includes clearly marked additional information that will not be included on tests. The additional information includes historical examples (Been there. Done that.), as well as facts and more in-depth information (Did you know …).

    INL criticality safety personnel revise this guide as needed to reflect program changes, user requests, and better information. Revision 0, issued May 2007, established the basic text. Revision 1 incorporates operation, program, and training changes implemented since 2007. Revision 1 increases focus on first responders because later responders are more likely to have more assistance and guidance from facility personnel and subject matter experts. Revision 1 also completely reorganized the training to better emphasize physical concepts behind the criticality controls that help keep emergency responders safe. The changes are based on and consistent with changes made to course 0INL1226.

  7. An Adaptive Voltage Control Algorithm with Multiple Distributed Energy

    SciTech Connect (OSTI)

    Li, Huijuan [University of Tennessee, Knoxville (UTK); Li, Fangxing [ORNL; Adhikari, Sarina [ORNL; Xu, Yan [ORNL; Rizy, D Tom [ORNL; Kueck, John D [ORNL

    2009-01-01T23:59:59.000Z

    Distributed energy resources (DE) with power electronics (PE) interfaces with the right control are capable of providing reactive power related ancillary services. Voltage regulation in particular has drawn much attention. In this paper the challenges to control multiple DEs to regulate the local voltage in distribution systems is addressed and a decentralized adaptive voltage control method is proposed. The simulation results in different system conditions show that this adaptive voltage control method is capable of satisfying the fast response speed requirement without causing oscillation or instability of the system. Since this method has high tolerance to the shortage of the system parameters and can be widely adaptive to the variable operation situations of the power systems, it is very suited for the utility application.

  8. Local Dynamic Reactive Power for Correction of System Voltage Problems

    SciTech Connect (OSTI)

    Kueck, John D [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Xu, Yan [ORNL; Li, Huijuan [University of Tennessee, Knoxville (UTK); Adhikari, Sarina [ORNL; Irminger, Philip [ORNL

    2008-12-01T23:59:59.000Z

    Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

  9. High voltage pulse conditioning

    DOE Patents [OSTI]

    Springfield, Ray M. (Sante Fe, NM); Wheat, Jr., Robert M. (Los Alamos, NM)

    1990-01-01T23:59:59.000Z

    Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

  10. Charge-pump voltage converter

    DOE Patents [OSTI]

    Brainard, John P. (Albuquerque, NM); Christenson, Todd R. (Albuquerque, NM)

    2009-11-03T23:59:59.000Z

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  11. INTEGRATED GHz VOLTAGE CONTROLLED OSCILLATORS

    E-Print Network [OSTI]

    Kinget, Peter

    INTEGRATED GHz VOLTAGE CONTROLLED OSCILLATORS Peter Kinget Bell Labs - Lucent Technologies Murray Hill, NJ (USA) Abstract The voltage controlled oscillator (VCO) is a critical sub. We focus on the de- sign of a critical sub-block: the voltage controlled oscillator (VCO). We review

  12. An improved voltage control on large-scale power system

    SciTech Connect (OSTI)

    Vu, H.; Pruvot, P.; Launay, C.; Harmand, Y. [Electricite de France, Clamart (France). Study and Research Div.] [Electricite de France, Clamart (France). Study and Research Div.

    1996-08-01T23:59:59.000Z

    To achieve a better voltage-var control in the electric power transmission system, different facilities are used. Generators are equipped with automatic voltage regulators to cope with sudden and random changes voltage caused by natural load fluctuations or failures. Other devices like capacitors, inductors, transformers with on load tap changers are installed on the network. Faced with the evolution of the network and operating conditions, electricity utilities are more and more interested in overall and coherent control systems, automatic or not. These systems are expected to coordinate the actions of local facilities for a better voltage control (more stable and faster reaction) inside different areas of the network in case of greater voltage and var variations. They affords besides a better use of existing reactive resources. Also, installation of new devices can be avoided allowing economy of investment. With this frame of mind, EDF has designed a system called Co-ordinated Secondary Voltage Control (CSVC). It`s an automatic closed loop system with a dynamic of a few minutes. It takes into account the network conditions (topology, loads), the voltage limits and the generator operating constraints. This paper presents recent improvements which allow the CSVC to control the voltage profile and different kinds of reactive means on a large-scale power system. Furthermore, this paper presents solution to spread out investment costs over several years, considering a deployment gradually extended.

  13. High voltage electrical amplifier having a short rise time

    DOE Patents [OSTI]

    Christie, David J. (Pleasanton, CA); Dallum, Gregory E. (Livermore, CA)

    1991-01-01T23:59:59.000Z

    A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage.

  14. Respond to the article | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingof Enhanced Dr. JuliaPOINT OFRespondRespond toRespond

  15. Respond to the article | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic2 OPAM615_CostNSAR -Department ofEMSpentResidential ClothesRespond to theRespond

  16. Responding to Changing Workforce Needs and Challenges

    E-Print Network [OSTI]

    Responding to Changing Workforce Needs and Challenges Dennis Ray Deputy Director Power Systems · Future Grid for Enabling Sustainable Energy Systems · Almost industry members,13 universities, 50 workers. Mid-career gap. Source: Gaps in the Energy Workforce Pipeline, Center for Energy Workforce

  17. Homeowners: Respond to Natural Gas Disruptions | Department of...

    Office of Environmental Management (EM)

    Natural Gas Disruptions Homeowners: Respond to Natural Gas Disruptions Homeowners: Respond to Natural Gas Disruptions Because natural gas is distributed through underground...

  18. Local Leaders: Respond to Natural Gas Disruptions | Department...

    Office of Environmental Management (EM)

    Natural Gas Disruptions Local Leaders: Respond to Natural Gas Disruptions Local Leaders: Respond to Natural Gas Disruptions Because natural gas is distributed through underground...

  19. Power flow analysis for DC voltage droop controlled DC microgrids

    E-Print Network [OSTI]

    Chaudhary, Sanjay

    loss, such as photovoltaic panels, batteries, fuel cells, LEDs, and electronic loads, DC microgrids sharing and secondary voltage regulation can now be analytically studied, and specialized optimization of the DC microgrid, in term of systematic analysis, protection coordination design, network optimization

  20. Reactive Power Sharing and Voltage Harmonic Distortion Compensation of Droop Controlled

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    1 Reactive Power Sharing and Voltage Harmonic Distortion Compensation of Droop Controlled Single, the inverters typically employ the droop control scheme. Traditional droop control enables the decentralized regulation of the local voltage and frequency of the microgrid by the inverters. The droop method also

  1. Voltage Control of Distribution Networks with Distributed Generation using Reactive Power

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Voltage Control of Distribution Networks with Distributed Generation using Reactive Power to control voltage of distribution networks with DG using reactive power compensation approach. In this paper profile within the specified limits, it is essential to regulate the reactive power of the compensators

  2. Training For Radiation Emergencies, First Responder Operations- Course Presentation

    Broader source: Energy.gov [DOE]

    Presentation slides use in the Training For Radiation Emergencies, First Responder Operations refresher training course.

  3. Nonlinear DSTATCOM controller design for distribution network with distributed generation to enhance voltage stability

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Nonlinear DSTATCOM controller design for distribution network with distributed generation Accepted 19 June 2013 Keywords: Distributed generation Distribution network DSATACOM Partial feedback connected to a distribution network with distributed generation (DG) to regulate the line voltage

  4. Responding to Emergencies | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilA groupTuba City,Enriched UraniumPhysical SecurityResponding to Emergencies |

  5. Respond to the article | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingof Enhanced Dr. JuliaPOINT OFRespond toRespond

  6. Respond to the article | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingof Enhanced Dr. JuliaPOINT OFRespondRespond to the

  7. Respond to the article | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingof Enhanced Dr. JuliaPOINT OFRespondRespond

  8. Respond to the article | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCO OverviewRepository | Department of EnergyDepartment ofRespond to the

  9. Respond to the article | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCO OverviewRepository | Department of EnergyDepartment ofRespond to

  10. Respond to the article | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCO OverviewRepository | Department of EnergyDepartment ofRespond to19, 2013

  11. Respond to the article | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCO OverviewRepository | Department of EnergyDepartment ofRespond to19,

  12. Respond to the article | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCO OverviewRepository | Department of EnergyDepartment ofRespond

  13. Respond to the article | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCO OverviewRepository | Department of EnergyDepartment ofRespondJune 20,

  14. Respond to the article | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCO OverviewRepository | Department of EnergyDepartment ofRespondJune

  15. Respond to the article | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCO OverviewRepository | Department of EnergyDepartment ofRespondJune3, 2014

  16. Respond to the article | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCO OverviewRepository | Department of EnergyDepartment ofRespondJune3,

  17. Respond to the article | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCO OverviewRepository | Department of EnergyDepartment ofRespondJune3,4,

  18. Respond to the article | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCO OverviewRepository | Department of EnergyDepartment ofRespondJune3,4,10,

  19. Respond to the article | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic2 OPAM615_CostNSAR -Department ofEMSpentResidential ClothesRespond to the

  20. Respond to the article | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic2 OPAM615_CostNSAR -Department ofEMSpentResidential ClothesRespond to

  1. Respond to the article | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic2 OPAM615_CostNSAR -Department ofEMSpentResidential ClothesRespond toSeptember

  2. Respond to the article | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic2 OPAM615_CostNSAR -Department ofEMSpentResidential ClothesRespond

  3. High voltage bus and auxiliary heater control system for an electric or hybrid vehicle

    DOE Patents [OSTI]

    Murty, Balarama Vempaty (West Bloomfield, MI)

    2000-01-01T23:59:59.000Z

    A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

  4. E-beam high voltage switching power supply

    DOE Patents [OSTI]

    Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

    1997-01-01T23:59:59.000Z

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

  5. E-beam high voltage switching power supply

    DOE Patents [OSTI]

    Shimer, D.W.; Lange, A.C.

    1997-03-11T23:59:59.000Z

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

  6. Dynamic simulation of voltage collapses

    SciTech Connect (OSTI)

    Deuse, J.; Stubbe, M. (Tractebel, Brussels (Belgium))

    1993-08-01T23:59:59.000Z

    Most of the time the voltage collapse phenomena are studied by means of computer programs designed for the calculation of steady state conditions. But in the real world, the simultaneous occurrences of losses of synchronism, of AVR dynamics or of transformer tap changes call for a full dynamic simulation of voltage phenomena. The present paper shows some examples of dynamic simulations of voltage phenomena using a new general purpose stability program (EUROSTAG), covering in a continuous way the classical fields of transient, mid-term and long-term stability, and also the quasi steady state conditions of a power system.

  7. Voltage tunable microwave ferrite resonator

    E-Print Network [OSTI]

    Oates, Daniel E.

    A novel method of implementing a tunable resonator using an applied voltage is presented. Stress is used to tune a microstrip resonator fabricated on a polycrystalline ferrite substrate. The stress was applied either ...

  8. How Do I Know? A Guide to the Selection of Personal Protective Equipment for Use in Responding to A Release of Chemical Warfare Agents

    SciTech Connect (OSTI)

    Foust, C.B.

    1999-05-01T23:59:59.000Z

    An incident involving chemical warfare agents requires a unique hazardous materials (HAZMAT) response. As with an HAZMAT event, federal regulations prescribe that responders must be protected from exposure to the chemical agents. But unlike other HAZMAT events, special considerations govern selection of personal protective equipment (PPE). PPE includes all clothing, respirators and monitoring devices used to respond to a chemical release. PPE can differ depending on whether responders are military or civilian personnel.

  9. ABBGroup-1-High voltage lab

    E-Print Network [OSTI]

    Basse, Nils Plesner

    . GENERATION System voltage: 12-24 kV Rated current: 6000-24000 A Max. short-circuit current: 50-500 kA TRANSMISSION System voltage: 72-800 kV Rated current: 2500-4000 A Max. short-circuit current: 25-63 k. It is designed to protect an electrical circuit from damage caused by overload or short-circuit. A circuit

  10. A Matter of Quantum Voltages

    SciTech Connect (OSTI)

    Sellner, Bernhard; Kathmann, Shawn M.

    2014-11-14T23:59:59.000Z

    Voltages inside matter are relevant to crystallization, materials science, biology, catalysis, and aqueous chemistry. Electron holography is able to measure the variation of voltages in matter and modern supercomputers allow the calculation of quantum voltages with practically unlimited spatial and temporal resolution of bulk systems. Of particular interest is the Mean Inner Potential (Vo) - the spatial average of these voltages. Voltages are very sensitive to the distribution of electrons and provide metrics to understand interactions in condensed phases. In the present study, we find excellent agreement with measurements of Vo for vitrified water and salt crystals and demonstrate the impact of covalent and ionic bonding as well as intermolecular/atomic interactions. Furthermore, we predict Vo as well as the fluctuations of these voltages in aqueous NaCl electrolytes and characterize the changes in their behavior as the resolution increases below the size of atoms. This work was supported by the U.S. Department of Energy, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences & Biosciences. Pacific Northwest National Laboratory (PNNL) is a multiprogram national laboratory operated for DOE by Battelle. This research used resources of the National Energy Research Scientific Computing Center, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231.

  11. Biodetection Technologies for First Responders: 2014 Edition

    SciTech Connect (OSTI)

    Ozanich, Richard M.; Baird, Cheryl L.; Bartholomew, Rachel A.; Colburn, Heather A.; Straub, Tim M.; Bruckner-Lea, Cindy J.

    2014-03-28T23:59:59.000Z

    This report summarizes commercially-available, hand-portable technologies that can be used by first responders in the field. This is not meant to be an exhaustive list, nor an endorsement of any technology described herein. Rather, this report is meant to provide useful information about available technologies to help end-users make informed decisions about biodetection technology procurement and use. Information listed in this report is primarily vendor-provided; however, where possible it has been supplemented with additional information obtained from publications, reports, and websites. Manufacturers were given the chance to review summaries of their technologies from August through November 2013 to verify the accuracy of technical specifications, available references, and pricing.

  12. Library Regulations Library Regulations

    E-Print Network [OSTI]

    Birmingham, University of

    Library Regulations 2012-13 Library Regulations UNIVERSITY OF BIRMINGHAM REGULATIONS LIBRARY REGULATIONS Preamble: The Library Regulations apply to all users of library facilities managed on behalf of the University by Library Services, and thus there are sections that apply also to non- members of the University

  13. Voltage, energy and power in electric circuits

    E-Print Network [OSTI]

    Berzins, M.

    Voltage, energy and power in electric circuits Science teaching unit #12;Disclaimer The Department-2008DVD-EN Voltage, energy and power in electric circuits #12;#12;© Crown copyright 2008 1The National Strategies | Secondary Voltage, energy and power in electric circuits 00094-2008DVD-EN Contents Voltage

  14. Voltage control in pulsed system by predict-ahead control

    DOE Patents [OSTI]

    Payne, A.N.; Watson, J.A.; Sampayan, S.E.

    1994-09-13T23:59:59.000Z

    A method and apparatus for predict-ahead pulse-to-pulse voltage control in a pulsed power supply system is disclosed. A DC power supply network is coupled to a resonant charging network via a first switch. The resonant charging network is coupled at a node to a storage capacitor. An output load is coupled to the storage capacitor via a second switch. A de-Q-ing network is coupled to the resonant charging network via a third switch. The trigger for the third switch is a derived function of the initial voltage of the power supply network, the initial voltage of the storage capacitor, and the present voltage of the storage capacitor. A first trigger closes the first switch and charges the capacitor. The third trigger is asserted according to the derived function to close the third switch. When the third switch is closed, the first switch opens and voltage on the node is regulated. The second trigger may be thereafter asserted to discharge the capacitor into the output load. 4 figs.

  15. High voltage MOSFET switching circuit

    DOE Patents [OSTI]

    McEwan, T.E.

    1994-07-26T23:59:59.000Z

    The problem of source lead inductance in a MOSFET switching circuit is compensated for by adding an inductor to the gate circuit. The gate circuit inductor produces an inductive spike which counters the source lead inductive drop to produce a rectangular drive voltage waveform at the internal gate-source terminals of the MOSFET. 2 figs.

  16. High voltage MOSFET switching circuit

    DOE Patents [OSTI]

    McEwan, Thomas E. (Livermore, CA)

    1994-01-01T23:59:59.000Z

    The problem of source lead inductance in a MOSFET switching circuit is compensated for by adding an inductor to the gate circuit. The gate circuit inductor produces an inductive spike which counters the source lead inductive drop to produce a rectangular drive voltage waveform at the internal gate-source terminals of the MOSFET.

  17. Voltage polarity manipulation of the magnetoresistance sign in organic spin valve devices

    SciTech Connect (OSTI)

    Jiang, S. W.; Chen, B. B.; Wang, P.; Zhou, Y.; Shi, Y. J.; Yue, F. J.; Ding, H. F.; Wu, D., E-mail: dwu@nju.edu.cn [National Laboratory of Solid State Microstructures and Department of Physics, Nanjing University, 22 Hankou Road, Nanjing 210093 (China)

    2014-06-30T23:59:59.000Z

    The spin transport in organic spin valve (OSV) devices has been systematically investigated by inserting a low work function material Al between ferromagnetic electrode and organic layer. The resistance and current-voltage curve symmetry are dramatically altered as increasing Al thickness, indicating that an electron-unipolar OSV is obtained. Moreover, the magnetoresistance sign depends on the voltage polarity for certain Al thickness. We attribute this phenomenon to the Fermi and the lowest unoccupied molecular orbits energies of the two electrodes responding to the spin injection and detection, respectively. These findings provide a simple approach to control both the carrier type and the spin direction simultaneously.

  18. NNSA hosts Illinois emergency responders during technical exchange...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Press Releases Video Gallery Photo Gallery Jobs Apply for Our Jobs Our Jobs Working at NNSA Blog Home NNSA Blog NNSA hosts Illinois emergency responders during technical ......

  19. Energy Department Emergency Response Team Ready to Respond to...

    Energy Savers [EERE]

    in Boston, New York, Philadelphia and Atlanta. An emergency responder is also deployed to Puerto Rico as part of an Incident Management Assistance Team on the island. Emergency...

  20. National Hydrogen Safety Training Resource for Emergency Responders...

    Broader source: Energy.gov (indexed) [DOE]

    slides from the Fuel Cell Technologies Office webinar "National Hydrogen Safety Training Resource for Emergency Responders" held on March 24, 2015. National Hydrogen Safety...

  1. Secretary of Energy's First Biennial Report to Congress Responding...

    Energy Savers [EERE]

    Secretary of Energy's First Biennial Report to Congress Responding to Hydrogen and Fuel Cell Technical Advisory Committee (HTAC) Findings and Recommendations during Fiscal Year...

  2. Webinar: National Hydrogen Safety Training Resource for Emergency Responders

    Broader source: Energy.gov [DOE]

    Text version and video recording of the Fuel Cell Technologies Office webinar titled "National Hydrogen Safety Training Resource for Emergency Responders," originally presented on March 24, 2015.

  3. High Power, High Voltage FETs in Linear Applications: A User's Perspective

    SciTech Connect (OSTI)

    N. Greenough, E. Fredd, S. DePasquale

    2009-09-21T23:59:59.000Z

    The specifications of the current crop of highpower, high-voltage field-effect transistors (FETs) can lure a designer into employing them in high-voltage DC equipment. Devices with extremely low on-resistance and very high power ratings are available from several manufacturers. However, our experience shows that high-voltage, linear operation of these devices at near-continuous duty can present difficult reliability challenges at stress levels well-below their published specifications. This paper chronicles the design evolution of a 600 volt, 8 ampere shunt regulator for use with megawatt-class radio transmitters, and presents a final design that has met its reliability criteria.

  4. FLORIDA ATLANTIC UNIVERSITY NOTICE OF PROPOSED NEW REGULATION

    E-Print Network [OSTI]

    Richman, Fred

    FLORIDA ATLANTIC UNIVERSITY NOTICE OF PROPOSED NEW REGULATION Date: April 16, 2009 REGULATION TITLE AND NUMBER: Institutes and Centers (2.006). SUMMARY: Board of Governors Regulation 10.015(3), University with Board of Governors criteria. Proposed Regulation 2.006 responds to this requirement and provides

  5. High voltage photovoltaic power converter

    DOE Patents [OSTI]

    Haigh, Ronald E. (Arvada, CO); Wojtczuk, Steve (Cambridge, MA); Jacobson, Gerard F. (Livermore, CA); Hagans, Karla G. (Livermore, CA)

    2001-01-01T23:59:59.000Z

    An array of independently connected photovoltaic cells on a semi-insulating substrate contains reflective coatings between the cells to enhance efficiency. A uniform, flat top laser beam profile is illuminated upon the array to produce electrical current having high voltage. An essentially wireless system includes a laser energy source being fed through optic fiber and cast upon the photovoltaic cell array to prevent stray electrical signals prior to use of the current from the array. Direct bandgap, single crystal semiconductor materials, such as GaAs, are commonly used in the array. Useful applications of the system include locations where high voltages are provided to confined spaces such as in explosive detonation, accelerators, photo cathodes and medical appliances.

  6. Modeling and Testing of Unbalanced Loading and Voltage Regulation

    SciTech Connect (OSTI)

    Davis, M. W.; Broadwater, R.; Hambrick, J.

    2007-07-01T23:59:59.000Z

    This report covers work to (1) develop and validate distribution circuit models, (2) determine optimum distributed generator operating conditions, and (3) determine distributed generation penetration limits.

  7. VRCon: Dynamic Reconfiguration of Voltage Regulators in a

    E-Print Network [OSTI]

    Pedram, Massoud

    dissipations of all VRs can result in a considerable amount of power loss. Introduction (2/3) Mar-27-14 4 2 2 current vs. efficiency, simulated by the VR schematics and 45nm PTM. The main source of the power loss

  8. A Local Control Approach to Voltage Regulation in Distribution Networks

    E-Print Network [OSTI]

    Liberzon, Daniel

    each bus updates the reactive power injection provided by their DER. The update at a bus only depends power from the utility feeder to the end consumers of electricity. These consumers are seen as a set of passive loads, and generally, the utility has no control of their electricity demand, and does not collect

  9. Regulation XVI: GENERAL UNIVERSITY REGULATIONS

    E-Print Network [OSTI]

    Regulation XVI: GENERAL UNIVERSITY REGULATIONS APPLICATION AND INTERPRETATION 1. Unless stated otherwise, these and the following Regulations apply to students in all Faculties, including the International Faculty: General Regulations for First Degrees; General Regulations for Higher Degrees

  10. Low power, scalable multichannel high voltage controller

    DOE Patents [OSTI]

    Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

    2008-03-25T23:59:59.000Z

    A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

  11. Low power, scalable multichannel high voltage controller

    DOE Patents [OSTI]

    Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

    2006-03-14T23:59:59.000Z

    A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

  12. Voltage Vehicles | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTown of Ladoga,planningFlowmeterUtah: Energydba Vision Motor CorpEIAVogtVoltage

  13. Webinar: National Hydrogen Safety Training Resource for Emergency Responders

    Broader source: Energy.gov [DOE]

    The Energy Department's Fuel Cell Technologies Office announces the launch of a new, free, online national hydrogen safety training resource for emergency responders. This webinar will provide additional details about the emergency response hydrogen training resource.

  14. Federal policy towards emergency responder interoperability : a path forward

    E-Print Network [OSTI]

    Weir, Tristan John

    2006-01-01T23:59:59.000Z

    Emergency responders have suffered from a lack of cross-agency radio communications for the past three decades. After numerous firefighters died in the terrorist attacks of September 11, partially due to a lack of ...

  15. Review of Requirements and Capabilities For Analyzing and Responding...

    Broader source: Energy.gov (indexed) [DOE]

    and Capabilities for Analyzing and Responding to Beyond Design Basis Events Office of Nuclear Safety Office of Health, Safety and Security U.S. Department of Energy August 2011...

  16. Patterns for responding to climate in shared-wall housing

    E-Print Network [OSTI]

    Paulos, Susan Kaufmann

    1982-01-01T23:59:59.000Z

    Out of the inescapables of building come inspiration for architectural design. Decisions which respond to climate make their mark in design, just as structural requirements, lighting provisions, and the limitations of a ...

  17. Wind Power Plant Voltage Stability Evaluation: Preprint

    SciTech Connect (OSTI)

    Muljadi, E.; Zhang, Y. C.

    2014-09-01T23:59:59.000Z

    Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

  18. Regulation loops for the ring magnet power supplies in the SSC accelerator complex

    SciTech Connect (OSTI)

    Tacconi, E.; Christiansen, C.

    1993-05-01T23:59:59.000Z

    The SSC complex consists of five cascaded accelerators: The linear accelerator (linac) and four synchrotrons: The low energy booster (LEB), the medium energy booster (MEB), the high energy booster (HEB), and the collider. Twelve- or 24-pulse phase-controlled SCR power supplies are used to energize the ring magnets. Each power supply has a voltage loop designed to regulate the voltage applied to the magnets. The voltage regulation loops for these synchrotrons and the current regulation for the LEB are analyzed in this work. The digital voltage regulator is fiber-optic isolated from the power converter. It has a closed-loop bandwidth of 150 Hz with band rejections for 60-Hz and 120-Hz perturbations. The LEB has a very precise current regulation system composed of a feedforward compensator, a fast feedback regulator, and a slow synchronous regulator. The current regulation design is corroborated by computer simulations.

  19. Supply Regulation Techniques for Phase-Locked Loops

    E-Print Network [OSTI]

    Palermo, Sam

    Supply Regulation Techniques for Phase-Locked Loops Vivekananth Gurumoorthy and Samuel Palermo-- Phase-locked loops (PLLs) which employ voltage regulators for low supply-noise sensitivity often rely. This paper compares various supply regulation techniques on the basis of their ability to reject noise from

  20. Group 3: Humidity, Temperature, and Voltage (Presentation)

    SciTech Connect (OSTI)

    Wohlgemuth, J.

    2013-05-01T23:59:59.000Z

    Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

  1. Sacramento Area Voltage Support - Environment - Sierra Nevada...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    (SMUD), Roseville Electric (Roseville), and the California Independent System Operator (ISO) grid. Western prepared a Sacramento Voltage Support (SVS) Draft Environmental Impact...

  2. DECENTRALIZED VOLTAGE CONTROL TO MINIMIZE DISTRIBUTION LOSSES IN AN ISLANDED MICROGRID

    E-Print Network [OSTI]

    Peng, Huei

    to deploy renewable energy sources such as solar and wind to reduce reliance on fossil fuels. In addition by inverters, there may not exist any inertia at all. In such cases, regulating the grid frequency becomes power sources and energy storage systems such as batteries requires new power and voltage control

  3. Energy-EfficientLow-VoltageOperation of Digital CMOS Circuits Through Charge-Recycling

    E-Print Network [OSTI]

    Shepard, Kenneth

    20.4 Energy-EfficientLow-VoltageOperation of Digital CMOS Circuits Through Charge regulator is a power transistor (shown as a variable This paper describes an energy-efficient means" to supply energy for another. When the domains are ideally balanced, all the energy dissipated by electrons

  4. Plug-and-play voltage and frequency control of islanded microgrids with meshed topology

    E-Print Network [OSTI]

    Ferrari-Trecate, Giancarlo

    generation since, differently from common diesel generators, power is produced and delivered to the main grid Generation Units (DGUs). Local controllers regulate voltage and frequency at the Point of Common Coupling Distributed Generation Units (DGUs) designed to operate safely and reliably in absence of a connection

  5. Capturing power at higher voltages from arrays of microbial fuel cells without voltage reversal

    E-Print Network [OSTI]

    is too low to be used directly for many practical applications. For example, a single light emitting diode (LED) requires a minimum voltage of 2 V.2 Thus, effective methods of boosting MFC voltages

  6. The Constant Voltage Transformer (CVT) for Mitigating Effects of Voltage Sags on Industrial Equipment

    E-Print Network [OSTI]

    Ferraro, R. J.; Osborne, R.; Stephens, R.

    ) an increase in loads that use power electronics in some type of power conversion configuration [1][2]. This paper presents applications of the constant-voltage transformer (CVT) for mitigating the effects of electric service voltage sags on industrial...

  7. ANALYSIS AND CHARACTERIZATION OF A PROGRAMMABLE LOW-DROPOUT REGULATOR

    E-Print Network [OSTI]

    Qiu, Xiaofan

    2007-09-17T23:59:59.000Z

    As portable electronic devices become a part of daily life, it creates a huge market for electronic components for those battery driven devices. Low-dropout (LDO) voltage regulator is an important part that provides steady DC supplies for other...

  8. Optimal Power Flow Incorporating Voltage Collapse Constraints

    E-Print Network [OSTI]

    Cañizares, Claudio A.

    Optimal Power Flow Incorporating Voltage Collapse Constraints William Rosehart Claudio Ca on the current operating con- ditions is presented. Second, an Optimal Power Flow formulation that incorporates: Voltage Collapse, Optimal Power Flow, Bifur- cations. I. Introduction As open-access market principles

  9. REDUCTION OF VOLTAGE VIOLATIONS FROM EMBEDDED GENERATORS

    E-Print Network [OSTI]

    Harrison, Gareth

    , and on the active and reactive power exported from the local busbar. Line power flow is reduced by local demand be used to attempt to maintain voltage. Recent work has considered the use of embedded diesel generators) If the EG tried to meet an excessive demand for reactive power, as voltage continued to fall, the AVR could

  10. Bi-directional power control system for voltage converter

    DOE Patents [OSTI]

    Garrigan, N.R.; King, R.D.; Schwartz, J.E.

    1999-05-11T23:59:59.000Z

    A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals. 10 figs.

  11. Bi-directional power control system for voltage converter

    DOE Patents [OSTI]

    Garrigan, Neil Richard (Niskayuna, NY); King, Robert Dean (Schenectady, NY); Schwartz, James Edward (Slingerlands, NY)

    1999-01-01T23:59:59.000Z

    A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals.

  12. Flexible method for monitoring fuel cell voltage

    DOE Patents [OSTI]

    Mowery, Kenneth D. (Noblesville, IN); Ripley, Eugene V. (Russiaville, IN)

    2002-01-01T23:59:59.000Z

    A method for equalizing the measured voltage of each cluster in a fuel cell stack wherein at least one of the clusters has a different number of cells than the identical number of cells in the remaining clusters by creating a pseudo voltage for the different cell numbered cluster. The average cell voltage of the all of the cells in the fuel cell stack is calculated and multiplied by a constant equal to the difference in the number of cells in the identical cell clusters and the number of cells in the different numbered cell cluster. The resultant product is added to the actual voltage measured across the different numbered cell cluster to create a pseudo voltage which is equivalent in cell number to the number of cells in the other identical numbered cell clusters.

  13. Corona and Motor Voltage Interim Report

    SciTech Connect (OSTI)

    Hsu, J.S.

    2005-05-06T23:59:59.000Z

    It has been suggested that to meet the FreedomCAR objectives for cost, size, weight, efficiency, and reliability higher buss voltages be utilized in HEV and FC automotive applications. The reasoning is that since electric power is equal to the product of voltage and current for a given power a higher voltage and lower current would result in smaller cable and inverter switching components. Consequently, the system can be lighter and smaller. On the other hand, higher voltages are known to require better and thicker electrical insulation that reduce the available slot area for motor windings. One cause of slow insulation breakdown is corona that gradually erodes the insulation and shortens the life expectancy of the motor. This study reports on the results of a study on corona initiating voltages for mush-wound and bobbin-wound stators. A unique testing method is illustrated.

  14. Non-contact current and voltage sensor

    DOE Patents [OSTI]

    Carpenter, Gary D; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C; Schappert, Michael A

    2014-03-25T23:59:59.000Z

    A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

  15. Wide-range voltage modulation

    SciTech Connect (OSTI)

    Rust, K.R.; Wilson, J.M.

    1992-06-01T23:59:59.000Z

    The Superconducting Super Collider`s Medium Energy Booster Abort (MEBA) kicker modulator will supply a current pulse to the abort magnets which deflect the proton beam from the MEB ring into a designated beam stop. The abort kicker will be used extensively during testing of the Low Energy Booster (LEB) and the MEB rings. When the Collider is in full operation, the MEBA kicker modulator will abort the MEB beam in the event of a malfunction during the filling process. The modulator must generate a 14-{mu}s wide pulse with a rise time of less than 1 {mu}s, including the delay and jitter times. It must also be able to deliver a current pulse to the magnet proportional to the beam energy at any time during ramp-up of the accelerator. Tracking the beam energy, which increases from 12 GeV at injection to 200 GeV at extraction, requires the modulator to operate over a wide range of voltages (4 kV to 80 kV). A vacuum spark gap and a thyratron have been chosen for test and evaluation as candidate switches for the abort modulator. Modulator design, switching time delay, jitter and pre-fire data are presented.

  16. PH-315 A. La Rosa VOLTAGE-CONTROLLED OSCILLATOR

    E-Print Network [OSTI]

    PH-315 A. La Rosa VOLTAGE-CONTROLLED OSCILLATOR 1. PURPOSE: An integrator and a Schmitt Trigger voltage; hence its name "voltage-controlled oscillator." 2. VOLTAGE-CONTROLLED OSCILLATOR Figure 1 shows voltage. An unusual feature of the circuit is its operation using a single positive supply.1 #12;- + 50k V

  17. The Role of U.S. Insurance Regulators in Responding to Climate Change

    E-Print Network [OSTI]

    Mills, Evan

    2008-01-01T23:59:59.000Z

    diseases exacerbated by temperature and water quality,or overwhelmed water treatment infrastruc- ture afterof malnutrition and water shortages in developing countries.

  18. The Role of U.S. Insurance Regulators in Responding to Climate Change

    E-Print Network [OSTI]

    Mills, Evan

    2008-01-01T23:59:59.000Z

    EXHIBIT 9. Range of carbon footprints for global insurers.their own carbon footprint insurer's own "carbon footprint." This includes minimizing

  19. Training For Radiation Emergencies, First Responder Operations- Instructors Guide

    Broader source: Energy.gov [DOE]

    The purpose of this program is to provide refresher operations training, as well as in-depth training in radiation, to fire fighters who are currently trained to the National Fire Protection Association (NFPA) Standard for Professional Competence of Responders to Hazardous Materials (NFPA 472).

  20. Training For Radiation Emergencies, First Responder Operations- Student Guide

    Broader source: Energy.gov [DOE]

    The purpose of this program is to provide refresher operations training, as well as in-depth training in radiation, to fire fighters who are currently trained to the National Fire Protection Association (NFPA) Standard for Professional Competence of Responders to Hazardous Materials (NFPA 472).

  1. Employment Status -All Respondents Full-time Employment -36%

    E-Print Network [OSTI]

    Plotkin, Joshua B.

    1 36% 4% 10% 28% 5% 5% 2% 1% 1% 8% Employment Status - All Respondents Full-time Employment - 36% Part-time Employment - 4% Continuing Current Employment - 10% Postdoctoral Fellowship - 28% Medical Residency (MD/PhDs) - 5% Full-time Graduate Studies - 5% Self-Employed - 2% Temporary Employment - 1% Other

  2. 12 August 2011 Top 4 Majors Among Respondents

    E-Print Network [OSTI]

    Hemmers, Oliver

    12 August 2011 Top 4 Majors Among Respondents 1. Accounting 2. Marketing 3. Management 4. Management Info Systems (MIS) 5. Management Information Systems (MIS) Percentage of Business Graduating Class (747) Represented by Survey All: 46/747 = 6% Undergraduates: 40/572 = 7% Graduates: 6/175= 3% Total

  3. Electro-optical voltage sensor head

    DOE Patents [OSTI]

    Woods, Gregory K. (Idaho Falls, ID)

    1998-01-01T23:59:59.000Z

    A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

  4. Strategies for Voltage Control and Transient Stability Assessment

    SciTech Connect (OSTI)

    Hiskens, Ian A.

    2013-09-25T23:59:59.000Z

    As wind generation grows, its influence on power system performance will becoming increasingly noticeable. Wind generation di#11;ffers from traditional forms of generation in numerous ways though, motivating the need to reconsider the usual approaches to power system assessment and performance enhancement. The project has investigated the impact of wind generation on transient stability and voltage control, identifying and addressing issues at three distinct levels of the power system: 1) at the device level, the physical characteristics of wind turbine generators (WTGs) are quite unlike those of synchronous machines, 2) at the wind-farm level, the provision of reactive support is achieved through coordination of numerous dissimilar devices, rather than straightforward generator control, and 3) from a systems perspective, the location of wind-farms on the sub-transmission network, coupled with the variability inherent in their power output, can cause complex voltage control issues. The project has sought to develop a thorough understanding of the dynamic behaviour of type-3 WTGs, and in particular the WECC generic model. The behaviour of such models is governed by interactions between the continuous dynamics of state variables and discrete events associated with limits. It was shown that these interactions can be quite complex, and may lead to switching deadlock that prevents continuation of the trajectory. Switching hysteresis was proposed for eliminating deadlock situations. Various type-3 WTG models include control blocks that duplicate integrators. It was shown that this leads to non-uniqueness in the conditions governing steady-state, and may result in pre- and post-disturbance equilibria not coinciding. It also gives rise to a zero eigenvalue in the linearized WTG model. In order to eliminate the anomalous behaviour revealed through this investigation, WECC has now released a new generic model for type-3 WTGs. Wind-farms typically incorporate a variety of voltage control equipment including tapchanging transformers, switched capacitors, SVCs, STATCOMs and the WTGs themselves. The project has considered the coordinated control of this equipment, and has addressed a range of issues that arise in wind-farm operation. The #12;first concerns the ability of WTGs to meet reactive power requirements when voltage saturation in the collector network restricts the reactive power availability of individual generators. Secondly, dynamic interactions between voltage regulating devices have been investigated. It was found that under certain realistic conditions, tap-changing transformers may exhibit instability. In order to meet cost, maintenance, fault tolerance and other requirements, it is desirable for voltage control equipment to be treated as an integrated system rather than as independent devices. The resulting high-level scheduling of wind-farm reactive support has been investigated. In addressing this control problem, several forms of future information were considered, including exact future knowledge and stochastic predictions. Deterministic and Stochastic Dynamic Programming techniques were used in the development of control algorithms. The results demonstrated that while exact future knowledge is very useful, simple prediction methods yield little bene#12;fit. The integration of inherently variable wind generation into weak grids, particularly subtransmission networks that are characterized by low X=R ratios, aff#11;ects bus voltages, regulating devices and line flows. The meshed structure of these networks adds to the complexity, especially when wind generation is distributed across multiple nodes. A range of techniques have been considered for analyzing the impact of wind variability on weak grids. Sensitivity analysis, based on the power-flow Jacobian, was used to highlight sections of a system that are most severely a#11;ffected by wind-power variations. A continuation power flow was used to determine parameter changes that reduce the impact of wind-power variability. It was also used to explore interactions betw

  5. Voltage instability: Mechanisms and control strategies

    SciTech Connect (OSTI)

    Vu, K.T. [ABB Transmission Technology Inst., Raleigh, NC (United States). Power Systems Center] [ABB Transmission Technology Inst., Raleigh, NC (United States). Power Systems Center; Liu, C.C. [Univ. of Washington, Seattle, WA (United States)] [Univ. of Washington, Seattle, WA (United States); Taylor, C.W. [Bonneville Power Administration, Portland, OR (United States)] [Bonneville Power Administration, Portland, OR (United States); Jimma, K.M. [Puget Sound Power and Light Co., Bellevue, WA (United States)] [Puget Sound Power and Light Co., Bellevue, WA (United States)

    1995-11-01T23:59:59.000Z

    One of the main objectives in operating an electric power system is to maintain a proper voltage level throughout a system. Failure to do so can lead to equipment damage and blackout. The article discusses the nonlinear aspects of power systems, with emphasis on voltage instability. It provides an overview of the state-of-the-art on the analysis and control of voltage dynamics. Dynamic mechanisms and control strategies are discussed from both theoretical and practical standpoints. The remedial controls implemented in the Puget Sound region of the Pacific Northwest indicate the practical significance of the research area.

  6. RESPONDING TO SOLICITATIONS UNDER DOE WORK FOR OTHERS PROGRAM

    Energy Savers [EERE]

    This chapter provides guidance on the effect of laws, regulations, and statutes to DOENNSA WFO policy related to the prohibition of DOE Federally Funded Research and Development...

  7. Characterizing and responding to uncertainty in climate change

    E-Print Network [OSTI]

    Lemoine, Derek Mark

    2011-01-01T23:59:59.000Z

    Irreversible abatement investment under cost uncertainties:about other firms’ investment cost. Third, if the regulatorIn addition, while making investment costs heterogeneous

  8. U.S. First Responder Safety Training for Advanced Electric Drive...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    U.S. First Responder Safety Training for Advanced Electric Drive Vehicle Presentation U.S. First Responder Safety Training for Advanced Electric Drive Vehicle Presentation 2010 DOE...

  9. Voltage Management of Networks with Distributed Generation. 

    E-Print Network [OSTI]

    O'Donnell, James

    2008-01-01T23:59:59.000Z

    At present there is much debate about the impacts and benefits of increasing the amount of generation connected to the low voltage areas of the electricity distribution network. The UK government is under political ...

  10. Electro-optic high voltage sensor

    DOE Patents [OSTI]

    Davidson, James R.; Seifert, Gary D.

    2003-09-16T23:59:59.000Z

    A small sized electro-optic voltage sensor capable of accurate measurement of high voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation. A polarization beam displacer separates the input beam into two beams with orthogonal linear polarizations and causes one linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels effect elliptically polarizes the beam as it travels through the crystal. A reflector redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization. The system may include a detector for converting the output beams into electrical signals and a signal processor for determining the voltage based on an analysis of the output beams.

  11. Low voltage arc formation in railguns

    DOE Patents [OSTI]

    Hawke, R.S.

    1987-11-17T23:59:59.000Z

    A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile. 2 figs.

  12. Low voltage arc formation in railguns

    DOE Patents [OSTI]

    Hawke, Ronald S. (Livermore, CA)

    1987-01-01T23:59:59.000Z

    A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

  13. Low voltage arc formation in railguns

    DOE Patents [OSTI]

    Hawke, R.S.

    1985-08-05T23:59:59.000Z

    A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

  14. High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2012 DOE Hydrogen and Fuel Cells Program and...

  15. Addressing the Voltage Fade Issue with Lithium-Manganese-Rich...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials 2013 DOE...

  16. Addressing the Voltage Fade Issue with Lithium-Manganese-Rich...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials 2012 DOE Hydrogen and...

  17. Group 3: Humidity, Temperature, and Voltage

    Broader source: Energy.gov [DOE]

    This PowerPoint presentation, focused on humidity, temperature and voltage testing, was originally presented by John Wohlgemuth at the NREL 2013 PV Module Reliability Workshop on Feb. 26-27, 2013 in Denver, CO. It summarizes the activities of a working group chartered to develop accelerated stress tests that can be used as comparative predictors of module life versus stresses associated with humidity, temperature and voltage.

  18. Spark gap with low breakdown voltage jitter

    DOE Patents [OSTI]

    Rohwein, Gerald J. (Albuquerque, NM); Roose, Lars D. (Albuquerque, NM)

    1996-01-01T23:59:59.000Z

    Novel spark gap devices and electrodes are disclosed. The novel spark gap devices and electrodes are suitable for use in a variety of spark gap device applications. The shape of the electrodes gives rise to local field enhancements and reduces breakdown voltage jitter. Breakdown voltage jitter of approximately 5% has been measured in spark gaps according the invention. Novel electrode geometries and materials are disclosed.

  19. Spark gap with low breakdown voltage jitter

    DOE Patents [OSTI]

    Rohwein, G.J.; Roose, L.D.

    1996-04-23T23:59:59.000Z

    Novel spark gap devices and electrodes are disclosed. The novel spark gap devices and electrodes are suitable for use in a variety of spark gap device applications. The shape of the electrodes gives rise to local field enhancements and reduces breakdown voltage jitter. Breakdown voltage jitter of approximately 5% has been measured in spark gaps according the invention. Novel electrode geometries and materials are disclosed. 13 figs.

  20. Frequency regulator for synchronous generators

    DOE Patents [OSTI]

    Karlicek, R.F.

    1982-08-10T23:59:59.000Z

    The present invention is directed to a novel frequency regulator which controls a generator output frequency for variations in both the input power to the generator and the power supplied to an uncontrolled external load. The present invention further includes over current and current balance protection devices which are relatively inexpensive to manufacture, which may be encapsulated to provide protection from the operating environment and which respond more quickly than previously known electromechanical devices. 11 figs.

  1. Utility-Side Voltage and PQ Control with Inverter-based Photovoltaic Systems

    SciTech Connect (OSTI)

    Adhikari, Sarina [ORNL] [ORNL; Xu, Yan [ORNL] [ORNL; Li, Fangxing [ORNL] [ORNL; Li, Huijuan [ORNL] [ORNL; Kueck, John D [ORNL] [ORNL; Snyder, Isabelle B [ORNL] [ORNL; Barker, Thomas J. [Southern California Edison RTTC] [Southern California Edison RTTC; Hite, Ronald [Southern California Edison RTTC] [Southern California Edison RTTC

    2011-01-01T23:59:59.000Z

    Distributed energy resources (DER) are small generators located close to the load centers. The DERs that are integrated to the grid with the power electronic converter interfaces are capable of providing nonactive power in addition to active power. Hence, they are capable of regulating the voltages of the weak buses in the distribution systems. This paper discusses the voltage control capability of photovoltaic (PV) systems as compared to the traditional capacitor banks. The simulation results prove the effectiveness of dynamic voltage control capability of inverter-based PV. With the proper control algorithm, the active and nonactive power from the DERs like battery banks or solar photovoltaic can be controlled independently. This paper also presents the scenario of controlling the active and nonactive power from the PV array to track and supply the local load.

  2. Chapter 17. High-Voltage Systems and Dielectric Materials High-Voltage Systems and Dielectric Materials

    E-Print Network [OSTI]

    -Voltage Systems and Dielectric Materials 17-2 RLE Progress Report 152 provides very useful insight into pre-breakdown in high voltage conduction and breakdown phenomena. 1. Mechanisms Behind Positive Streamers and Their Distinct Propagation Modes in Transformer Oil Sponsors This work was supported by ABB Corporate Research

  3. A Charge Pump that Generates Negative High Voltage with Variable Voltage , Eugene Ivanova,

    E-Print Network [OSTI]

    Ayers, Joseph

    A Charge Pump that Generates Negative High Voltage with Variable Voltage Gain Jun Zhaob, , Eugene, Massachusetts 02115, U.S.A. Abstract A cross-coupled structure based charge pump that generates negative high. The proposed negative charge pump is designed to deliver 40 uA with a wide supply range from 2.5V to 5.5V using

  4. Distributed Voltage and Current Control of Multi-Terminal High-Voltage Direct

    E-Print Network [OSTI]

    Dimarogonas, Dimos

    }@kth.se.) Abstract: High-voltage direct current (HVDC) is a commonly used technology for long-distance power for multi-terminal HVDC (MTDC) systems is proposed. Under certain conditions on the controller gains factor behind long-distance power transmission. High-voltage direct current (HVDC) is a commonly used

  5. Experimental validation of a high voltage pulse measurement method.

    SciTech Connect (OSTI)

    Cular, Stefan; Patel, Nishant Bhupendra; Branch, Darren W.

    2013-09-01T23:59:59.000Z

    This report describes X-cut lithium niobate's (LiNbO3) utilization for voltage sensing by monitoring the acoustic wave propagation changes through LiNbO3 resulting from applied voltage. Direct current (DC), alternating current (AC) and pulsed voltage signals were applied to the crystal. Voltage induced shift in acoustic wave propagation time scaled quadratically for DC and AC voltages and linearly for pulsed voltages. The measured values ranged from 10 - 273 ps and 189 ps - 2 ns for DC and non-DC voltages, respectively. Data suggests LiNbO3 has a frequency sensitive response to voltage. If voltage source error is eliminated through physical modeling from the uncertainty budget, the sensor's U95 estimated combined uncertainty could decrease to ~0.025% for DC, AC, and pulsed voltage measurements.

  6. Application of PLM processes to respond to mechanical SMEs needs

    E-Print Network [OSTI]

    Julien Le Duigou; Alain Bernard; Nicolas Perry; Jean-Charles Delplace

    2010-11-26T23:59:59.000Z

    PLM is today a reality for mechanical SMEs. Some companies implement PLM systems very well but others have more difficulties. This paper aims to explain why some SMEs do not success to integrated PLM systems analyzing the needs of mechanical SMEs, the processes to implement to respond to those needs and the actual PLM software functionalities. The proposition of a typology of those companies and the responses of those needs by PLM processes will be explain through the applications of a demonstrator applying appropriate generic data model and modelling framework.

  7. Application of PLM processes to respond to mechanical SMEs needs

    E-Print Network [OSTI]

    Duigou, Julien Le; Perry, Nicolas; Delplace, Jean-Charles

    2010-01-01T23:59:59.000Z

    PLM is today a reality for mechanical SMEs. Some companies implement PLM systems very well but others have more difficulties. This paper aims to explain why some SMEs do not success to integrated PLM systems analyzing the needs of mechanical SMEs, the processes to implement to respond to those needs and the actual PLM software functionalities. The proposition of a typology of those companies and the responses of those needs by PLM processes will be explain through the applications of a demonstrator applying appropriate generic data model and modelling framework.

  8. Business Owners: Respond to an Energy Emergency | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube platformBuilding Removal Ongoing atGreenhouse GasesRespond to an Energy

  9. Responding To Hurricane Sandy: DOE Situation Reports | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCO OverviewRepository | Department of EnergyDepartmentResponding To

  10. Local Leaders: Respond to an Energy Emergency | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking ofOil & Gas »ofMarketing |Prepare for an Energy EmergencyRespond to an

  11. Business Owners: Respond to an Energy Emergency | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof Energy FutureDepartment ofBUILDING-TO-GRIDLight Wa BusinessRespond to an

  12. Compact high voltage solid state switch

    DOE Patents [OSTI]

    Glidden, Steven C.

    2003-09-23T23:59:59.000Z

    A compact, solid state, high voltage switch capable of high conduction current with a high rate of current risetime (high di/dt) that can be used to replace thyratrons in existing and new applications. The switch has multiple thyristors packaged in a single enclosure. Each thyristor has its own gate drive circuit that circuit obtains its energy from the energy that is being switched in the main circuit. The gate drives are triggered with a low voltage, low current pulse isolated by a small inexpensive transformer. The gate circuits can also be triggered with an optical signal, eliminating the trigger transformer altogether. This approach makes it easier to connect many thyristors in series to obtain the hold off voltages of greater than 80 kV.

  13. SiGe BiCMOS Topologies for Low-Voltage Millimeter-Wave Voltage Controlled Oscillators and Frequency Dividers

    E-Print Network [OSTI]

    Voinigescu, Sorin Petre

    SiGe BiCMOS Topologies for Low-Voltage Millimeter-Wave Voltage Controlled Oscillators and Frequency-mail: tod@eecg.toronto.edu Abstract -- BiCMOS topologies for mm-wave voltage- controlled oscillators operation for mm-wave applications. II. BICMOS VOLTAGE-CONTROLLED OSCILLATOR The Colpitts topology

  14. Electro-optic voltage sensor for sensing voltage in an E-field

    DOE Patents [OSTI]

    Woods, Gregory K. (Idaho Falls, ID); Renak, Todd W. (Idaho Falls, ID)

    1999-01-01T23:59:59.000Z

    A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

  15. Electro-optic voltage sensor for sensing voltage in an E-field

    DOE Patents [OSTI]

    Woods, G.K.; Renak, T.W.

    1999-04-06T23:59:59.000Z

    A miniature electro-optic voltage sensor system capable of accurate operation at high voltages is disclosed. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam`s polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured. 18 figs.

  16. Voltage control on a train system

    DOE Patents [OSTI]

    Gordon, Susanna P.; Evans, John A.

    2004-01-20T23:59:59.000Z

    The present invention provides methods for preventing low train voltages and managing interference, thereby improving the efficiency, reliability, and passenger comfort associated with commuter trains. An algorithm implementing neural network technology is used to predict low voltages before they occur. Once voltages are predicted, then multiple trains can be controlled to prevent low voltage events. Further, algorithms for managing inference are presented in the present invention. Different types of interference problems are addressed in the present invention such as "Interference During Acceleration", "Interference Near Station Stops", and "Interference During Delay Recovery." Managing such interference avoids unnecessary brake/acceleration cycles during acceleration, immediately before station stops, and after substantial delays. Algorithms are demonstrated to avoid oscillatory brake/acceleration cycles due to interference and to smooth the trajectories of closely following trains. This is achieved by maintaining sufficient following distances to avoid unnecessary braking/accelerating. These methods generate smooth train trajectories, making for a more comfortable ride, and improve train motor reliability by avoiding unnecessary mode-changes between propulsion and braking. These algorithms can also have a favorable impact on traction power system requirements and energy consumption.

  17. High Voltage Electrolyte for Lithium Batteries

    Broader source: Energy.gov (indexed) [DOE]

    Argonne's Fluorinated Compounds as High Voltage Electrolytes (HVEs) O O O O O O EC EMC O O O CF CF 3 CF 3 O O O CF 3 F 2 HC C F 2 O F 2 C CF 2 H 6 Code Name Chemical...

  18. Group 3: Humidity, Temperature and Voltage (Presentation)

    SciTech Connect (OSTI)

    Wohlgemuth, J.

    2013-09-01T23:59:59.000Z

    This is a summary of the work of Group 3 of the International PV QA Task Force. Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

  19. Energy Metering for Free: Augmenting Switching Regulators for Real-Time Monitoring

    E-Print Network [OSTI]

    Count, a new energy meter design. For many systems that have a built-in switching regulator, adding a single nearly linearly with load current for a variety of regulators. 1 The iCount Design Many battery a variety of regulator topologies (boost, buck, buck-boost), control modes (current-mode, voltage

  20. System Level Analysis of Fast, Per-Core DVFS using On-Chip Switching Regulators

    E-Print Network [OSTI]

    Brooks, David

    -level application of the regulator. In this paper, we describe and model these costs, and perform a comprehensive workloads found in modern systems, motivates the need for fast, per-core DVFS control. Voltage regulatorsSystem Level Analysis of Fast, Per-Core DVFS using On-Chip Switching Regulators Wonyoung Kim, Meeta

  1. LP3853/LP3856 3A Fast Response Ultra Low Dropout Linear Regulators

    E-Print Network [OSTI]

    Berns, Hans-Gerd

    LP3853/LP3856 3A Fast Response Ultra Low Dropout Linear Regulators General Description The LP3853/LP3856 series of fast ultra low-dropout linear regulators operate from a +2.5V to +7.0V input supply. Wide range of preset output voltage options are available. These ultra low dropout linear regulators

  2. Improving CS regulations.

    SciTech Connect (OSTI)

    Nesse, R.J.; Scheer, R.M.; Marasco, A.L.; Furey, R.

    1980-10-01T23:59:59.000Z

    President Carter issued Executive Order 12044 (3/28/78) that required all Federal agencies to distinguish between significant and insignificant regulations, and to determine whether a regulation will result in major impacts. This study gathered information on the impact of the order and the guidelines on the Office of Conservation and Solar Energy (CS) regulatory practices, investigated problems encountered by the CS staff when implementing the order and guidelines, and recommended solutions to resolve these problems. Major tasks accomplished and discussed are: (1) legislation, Executive Orders, and DOE Memoranda concerning Federal administrative procedures relevant to the development and analysis of regulations within CS reviewed; (2) relevant DOE Orders and Memoranda analyzed and key DOE and CS staff interviewed in order to accurately describe the current CS regulatory process; (3) DOE staff from the Office of the General Counsel, the Office of Policy and Evaluation, the Office of the Environment, and the Office of the Secretary interviewed to explore issues and problems encountered with current CS regulatory practices; (4) the regulatory processes at five other Federal agencies reviewed in order to see how other agencies have approached the regulatory process, dealt with specific regulatory problems, and responded to the Executive Order; and (5) based on the results of the preceding four tasks, recommendations for potential solutions to the CS regulatory problems developed. (MCW)

  3. Electro-optic high voltage sensor

    DOE Patents [OSTI]

    Davidson, James R. (Idaho Falls, ID); Seifert, Gary D. (Idaho Falls, ID)

    2002-01-01T23:59:59.000Z

    A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal having at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

  4. Multilevel Cascade H-bridge Inverter DC Voltage Estimation Through Output Voltage Sensing

    E-Print Network [OSTI]

    Tolbert, Leon M.

    system as the inverter power supply may vary. For example, interface of solar panels or fuel cell. The output voltage is then processed by a DSP unit that uses the signals that command the switches

  5. Three Human Cell Types Respond to Multi-Walled Carbon Nanotubes...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Human Cell Types Respond to Multi-Walled Carbon Nanotubes and Titanium Dioxide Nanobelts with Cell-Specific Transcriptomic Three Human Cell Types Respond to Multi-Walled Carbon...

  6. THE ADOPTION OF STATE ELECTRICITY REGULATION: THE ROLE OF INTEREST GROUPS

    E-Print Network [OSTI]

    Rothman, Daniel

    THE ADOPTION OF STATE ELECTRICITY REGULATION: THE ROLE OF INTEREST GROUPSĂ Christopher R. Knittelw This paper examines the adoption of state electricity regulation around the beginning of the 20th century. I residential electricity penetration rates. These results suggest that state regulation responded to regulatory

  7. Sacramento Area Voltage Support Final Environmental Impact Statement

    SciTech Connect (OSTI)

    N /A

    2003-09-19T23:59:59.000Z

    The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the National Environmental Policy Act (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: (1) Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; (2) Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and (3) Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

  8. Sacramento Area Voltage Support Draft Environmental Impact Statement

    SciTech Connect (OSTI)

    N /A

    2002-11-15T23:59:59.000Z

    The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the ''National Environmental Policy Act'' (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

  9. Reactive Support and Voltage Control Service: Key Issues and Challenges

    E-Print Network [OSTI]

    Gross, George

    reactive support and voltage control services. Keywords ­ Competitive Electricity Markets, Reactive PowerReactive Support and Voltage Control Service: Key Issues and Challenges George Gross^, Paolo Marannino° and Gianfranco Chicco* ^ Department of Electrical and Computer Engineering, University

  10. SLAC P2 Marx Control System and Regulation Scheme

    SciTech Connect (OSTI)

    MacNair, David; Kemp, Mark A.; Macken, Koen; Nguyen, Minh N.; Olsen, Jeff; /SLAC

    2011-05-20T23:59:59.000Z

    The SLAC P2 MARX Modulator consists of 32 cells charged in parallel by a -4 kV supply and discharged in series to provide a -120 kV 140 amp 1.7 millisecond pulse. Each cell has a 350 uF main storage capacitor. The voltage on the capacitor will droop approximately 640 volts during each pulse. Each cell will have a boost supply that can add up to 700 V to the cell output. This allows the output voltage of the cell to remain constant within 0.1% during the pulse. The modulator output voltage control is determined by the -4 kV charging voltage. A voltage divider will measure the modulator voltage on each pulse. The charging voltage will be adjusted by the data from previous pulses to provide the desired output. The boost supply in each cell consists of a 700 V buck regulator in series with the main capacitor. The supply uses a lookup table for PWM control. The lookup table is calculated from previous pulse data to provide a constant cell output. The paper will describe the modulator and cell regulation used by the MARX modulator. Measured data from a single cell and three cell string will be included.

  11. Electrical system architecture having high voltage bus

    DOE Patents [OSTI]

    Hoff, Brian Douglas (East Peoria, IL); Akasam, Sivaprasad (Peoria, IL)

    2011-03-22T23:59:59.000Z

    An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

  12. Low Voltage White Phosphorescent OLED Achievements

    Broader source: Energy.gov [DOE]

    Universal Display Corporation (UDC) and its research partners at Princeton University and the University of Southern California have succeeded in developing a white phosphorescent OLED (PHOLED™) that achieved a record efficiency of 20 lumens per watt. This achievement is the result of the team's collaborative efforts to increase the efficiency of PHOLED lighting by focusing on two critical factors: lowering the drive voltages and increasing the amount of light extracted.

  13. High Voltage Electrolyte for Lithium Batteries

    Broader source: Energy.gov (indexed) [DOE]

    5.0E-04 1.0E-03 2 2.2 2.4 2.6 2.8 Voltage (V) dQdV (AhV) 1 st Charge 1.2M LiPF 6 ECEMC 37 1 st Charge 1.0M LiPF 6 TMS1NM3 55 with 2% and 4% VC 1 st Charge 1.0M LiPF 6 TMS...

  14. Electrostatically screened, voltage-controlled electrostatic chuck

    DOE Patents [OSTI]

    Klebanoff, Leonard Elliott (San Ramon, CA)

    2001-01-01T23:59:59.000Z

    Employing an electrostatically screened, voltage-controlled electrostatic chuck particularly suited for holding wafers and masks in sub-atmospheric operations will significantly reduce the likelihood of contaminant deposition on the substrates. The electrostatic chuck includes (1) an insulator block having a outer perimeter and a planar surface adapted to support the substrate and comprising at least one electrode (typically a pair of electrodes that are embedded in the insulator block), (2) a source of voltage that is connected to the at least one electrode, (3) a support base to which the insulator block is attached, and (4) a primary electrostatic shield ring member that is positioned around the outer perimeter of the insulator block. The electrostatic chuck permits control of the voltage of the lithographic substrate; in addition, it provides electrostatic shielding of the stray electric fields issuing from the sides of the electrostatic chuck. The shielding effectively prevents electric fields from wrapping around to the upper or front surface of the substrate, thereby eliminating electrostatic particle deposition.

  15. Electro-optic voltage sensor head

    DOE Patents [OSTI]

    Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Woods, Gregory K. (Cornelius, OR)

    1999-01-01T23:59:59.000Z

    The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers.

  16. Electro-optic voltage sensor head

    DOE Patents [OSTI]

    Crawford, T.M.; Davidson, J.R.; Woods, G.K.

    1999-08-17T23:59:59.000Z

    The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers. 6 figs.

  17. Loop-voltage tomography in tokamaks using transient synchrotron radiation

    SciTech Connect (OSTI)

    Fisch, N.J.; Kritz, A.H. (Princeton Univ., NJ (USA). Plasma Physics Lab.; Hunter Coll., New York, NY (USA). Dept. of Physics)

    1989-07-01T23:59:59.000Z

    The loop voltage in tokamaks is particularly difficult to measure anywhere but at the plasma periphery. A brief, deliberate, perturbation of hot plasma electrons, however, produces a transient radiation response that is sensitive to this voltage. We investigate how such a radiation response can be used to diagnose the loop voltage. 24 refs., 6 figs.

  18. Characterized ideal LC circuit Charge, current and voltage vary sinusoidally

    E-Print Network [OSTI]

    Bertulani, Carlos A. - Department of Physics and Astronomy, Texas A&M University

    resistance to LC circuit Oscillations become damped Charge, current and voltage still vary sinusoidally Oscillations Draw phasors for voltages of R, C and L at same time t Orient VR, VL, & VC phasors relativeReview Characterized ideal LC circuit Charge, current and voltage vary sinusoidally Added

  19. Accurately measuring current-voltage characteristics of tunnel diodes

    E-Print Network [OSTI]

    Bao, Mingqiang; Wang, Kang L

    2006-01-01T23:59:59.000Z

    of the bias voltage range of oscillations in the I–V curve.and the bias voltage range of oscillation in the I–V curve.or to know the exact voltage range of oscillation in the I–V

  20. DCS1800/WCDMA ADAPTIVE VOLTAGE-CONTROLLED OSCILLATOR

    E-Print Network [OSTI]

    Serdijn, Wouter A.

    DCS1800/WCDMA ADAPTIVE VOLTAGE-CONTROLLED OSCILLATOR Aleksandar Tasiü, Wouter A. Serdijn and John R, an adaptive 2G/3G voltage-controlled oscillator (VCO) is described in this paper. For the DCS1800 operation with this reasoning, an adaptive 2G/3G voltage- controlled oscillator, meant for a dual-standard adaptive front

  1. Selective compensation of voltage harmonics in grid-connected microgrids

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    1 Selective compensation of voltage harmonics in grid-connected microgrids Mehdi Savaghebia , Juan is proposed for selective compensation of main voltage harmonics in a grid- connected microgrid. The aim level. Keywords Distributed Generator (DG); microgrid; grid-connected; voltage harmonics compensation. 1

  2. Structural Optimization of High Voltage Transmission Line Towers considering

    E-Print Network [OSTI]

    Colominas, Ignasi

    Structural Optimization of High Voltage Transmission Line Towers considering Continuum and Discrete/or to common designs largely repeated (e.g. automotive compo- nents), and high voltage transmission towers can than conventional designs of high voltage transmission line towers. The optimization model proposed

  3. System for increasing corona inception voltage of insulating oils

    DOE Patents [OSTI]

    Rohwein, G.J.

    1998-05-19T23:59:59.000Z

    The Corona Inception Voltage of insulating oils is increased by repetitive cycles of prestressing the oil with a voltage greater than the corona inception voltage, and either simultaneously or serially removing byproducts of corona by evacuation and heating the oil. 5 figs.

  4. Electrical Circuit Flashover Model of Polluted Insulators under AC Voltage Based on the Arc Root Voltage Gradient Criterion

    E-Print Network [OSTI]

    Yang, Qing

    In order to study the flashover mechanism of polluted insulators under AC voltage, a new arc propagation criterion which is based on an arc root voltage gradient is proposed. This criterion can explain the variation of the ...

  5. Regulation XVII: GENERAL REGULATIONS FOR FIRST DEGREES

    E-Print Network [OSTI]

    Regulation XVII: GENERAL REGULATIONS FOR FIRST DEGREES SCOPE OF THESE REGULATIONS4 1. These Regulations apply, subject to any different provision in the Regulations for a particular programme of study programme of study is designated as a non-modular programme, Regulation 14 and subsequent Regulations

  6. Alternative Regulation (Vermont)

    Broader source: Energy.gov [DOE]

    Utility regulators, including the Public Service Board, have applied a new type of regulation, often called "alternative regulation" or "incentive regulation." There are many variants of this type...

  7. Government Regulation

    E-Print Network [OSTI]

    Ashford, Nicholas

    2005-01-01T23:59:59.000Z

    Abstract. Interest in the use of so-called voluntary approaches to supplement or replace formal environmental regulation is on the rise, both in Europe and in the United States. These approaches fall into two general ...

  8. Method of Controlling Corona Effects and Breakdown Voltage of Small Air Gaps Stressed by Impulse Voltages

    E-Print Network [OSTI]

    Athanasios Maglaras; Trifon Kousiouris; Frangiskos Topalis; Dimitrios Katsaros; Leandros A. Maglaras; Konstantina Giannakopoulou

    2014-10-15T23:59:59.000Z

    This paper investigates the influence of a resistor on the dielectric behavior of an air gap. The resistor is connected in series with the air gap and the latter is stressed by impulse voltage. Air gap arrangements of different geometry with either the rod or the plate grounded are stressed with impulse voltages of both positive and negative polarity. The resistor is connected in series with the air gap in the return circuit connecting the gap with the impulse generator. The method followed involves the investigation of the graphs of the charging time concerning the air gaps capacitances, in connection to the value of the resistor, the geometry of the gap, the effect of grounding and the polarity effect. It is determined that the charging time of the air gap increases, as the value of the resistor increases. It is also determined that the peak voltage value of the fully charged air gap decreases as the value of the resistor increases. The results of the mathematical and simulation analysis are compared with the results of the oscillograms taken from experimental work. In addition and consequently to the above results it is concluded from the experimental work that the in series connection of the resistor in the circuit has significant influence on corona pulses (partial discharges) occurring in the gap and on the breakdown voltage of the gap. A new method of controlling the corona effects and consequently the breakdown voltage of small air gaps stressed by impulse voltage of short duration in connection to the ground effect and the polarity effect has arisen. Furthermore through mathematical analysis of the charging graphs obtained from simulation and experimental oscillograms there was a calculation of the values of the capacitance of the air gaps in relation to their geometry and the results were compared to the values calculated with mathematical analysis.

  9. Apparatus for producing voltage and current pulses

    DOE Patents [OSTI]

    Kirbie, Hugh (Los Alamos, NM); Dale, Gregory E. (Los Alamos, NM)

    2010-12-21T23:59:59.000Z

    An apparatus having one or more modular stages for producing voltage and current pulses. Each module includes a diode charging means to charge a capacitive means that stores energy. One or more charging impedance means are connected to the diode charging means to provide a return current pathway. A solid-state switch discharge means, with current interruption capability, is connected to the capacitive means to discharge stored energy. Finally, a control means is provided to command the switching action of the solid-state switch discharge means.

  10. Production of high voltage by ion bombardment

    E-Print Network [OSTI]

    Phinney, Lucas Carter

    2003-01-01T23:59:59.000Z

    . . . 35 FIGIJRE Page 19 I-V curve for the ammeter setup . . 35 20 Diagram of the leakage current test setup . . . . . . 37 21 Voltmeter readings at each high voltage interval . . . . . , 38 CHAPTER I INTRODUCTION Direct energy conversion... streaming into the source There is also a moveable shutter that can stop the beam &om entering the beam line. A Varian VHS-6 diffusion pump is connected at the bottom of the glass cross. Its function is to maintain a vacuum in this part of the accelerator...

  11. Eliminate Voltage Unbalance | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube|6721 Federal Register / Vol.6:Energy|Electrifyingof EnergyVoltage

  12. Preventing and Responding to All Forms of Violence in the Workplace...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    P 444.1, Preventing and Responding to All Forms of Violence in the Workplace (Informational Purposes Only) by Beau Newman Functional areas: Workplace Violence, Employee Safety This...

  13. Education of First Responders at Yale | U.S. DOE Office of Science...

    Office of Science (SC) Website

    Education of First Responders at Yale Nuclear Physics (NP) NP Home About Research Facilities Science Highlights Benefits of NP Applications of Nuclear Science Applications of...

  14. Responding to the Risk of White Shark Attack Updated Statistics, Prevention, Control

    E-Print Network [OSTI]

    Klimley, A. Peter

    477 CHAPTER 31 Responding to the Risk of White Shark Attack Updated Statistics, Prevention, Control ................................................................................................................................... 478 White Shark Attack Statistics........................................................................................................ 479 Definition of Shark Attack

  15. Regulation 29: Other Regulations concerning the University site and buildings, Computing Regulations and Miscellaneous Administrative Regulations

    E-Print Network [OSTI]

    Sussex, University of

    Regulations and Miscellaneous Administrative Regulations 190 nuisance to occupants, except in designated (Vehicle Operators and Penalty Notices) Regulations; (iii) allow smoking in designated study bedroomsRegulation 29: Other Regulations concerning the University site and buildings, Computing

  16. Planar LTCC transformers for high voltage flyback converters.

    SciTech Connect (OSTI)

    Schofield, Daryl (NASCENT Technology Inc. , Watertown, SD); Schare, Joshua M.; Glass, Sarah Jill; Roesler, Alexander William; Ewsuk, Kevin Gregory; Slama, George (NASCENT Technology Inc. , Watertown, SD); Abel, Dave (NASCENT Technology Inc. , Watertown, SD)

    2007-06-01T23:59:59.000Z

    This paper discusses the design and use of low-temperature (850 C to 950 C) co-fired ceramic (LTCC) planar magnetic flyback transformers for applications that require conversion of a low voltage to high voltage (> 100V) with significant volumetric constraints. Measured performance and modeling results for multiple designs showed that the LTCC flyback transformer design and construction imposes serious limitations on the achievable coupling and significantly impacts the transformer performance and output voltage. This paper discusses the impact of various design factors that can provide improved performance by increasing transformer coupling and output voltage. The experiments performed on prototype units demonstrated LTCC transformer designs capable of greater than 2 kV output. Finally, the work investigated the effect of the LTCC microstructure on transformer insulation. Although this paper focuses on generating voltages in the kV range, the experimental characterization and discussion presented in this work applies to designs requiring lower voltage.

  17. Compensated gain control circuit for buck regulator command charge circuit

    DOE Patents [OSTI]

    Barrett, David M. (Albuquerque, NM)

    1996-01-01T23:59:59.000Z

    A buck regulator command charge circuit includes a compensated-gain control signal for compensating for changes in the component values in order to achieve optimal voltage regulation. The compensated-gain control circuit includes an automatic-gain control circuit for generating a variable-gain control signal. The automatic-gain control circuit is formed of a precision rectifier circuit, a filter network, an error amplifier, and an integrator circuit.

  18. Compensated gain control circuit for buck regulator command charge circuit

    DOE Patents [OSTI]

    Barrett, D.M.

    1996-11-05T23:59:59.000Z

    A buck regulator command charge circuit includes a compensated-gain control signal for compensating for changes in the component values in order to achieve optimal voltage regulation. The compensated-gain control circuit includes an automatic-gain control circuit for generating a variable-gain control signal. The automatic-gain control circuit is formed of a precision rectifier circuit, a filter network, an error amplifier, and an integrator circuit. 5 figs.

  19. Method for voltage-gated protein fractionation

    DOE Patents [OSTI]

    Hatch, Anson (Tracy, CA); Singh, Anup K. (Danville, CA)

    2012-04-24T23:59:59.000Z

    We report unique findings on the voltage dependence of protein exclusion from the pores of nanoporous polymer exclusion membranes. The pores are small enough that proteins are excluded from passage with low applied electric fields, but increasing the field enables proteins to pass through. The requisite field necessary for a change in exclusion is protein-specific with a correlation to protein size. The field-dependence of exclusion is important to consider for preconcentration applications. The ability to selectively gate proteins at exclusion membranes is also a promising means for manipulating and characterizing proteins. We show that field-gated exclusion can be used to selectively remove proteins from a mixture, or to selectively trap protein at one exclusion membrane in a series.

  20. Voltage controlled MESFET pulse shape generator

    SciTech Connect (OSTI)

    Burkhart, S.C.

    1994-10-26T23:59:59.000Z

    A programmable pulse shape generator capable of producing pulse shapes for Nova and Beamlet has been designed and simulated using the circuit code SPICE. The design utilizes power MESFETS, which are commonly used in microwave amplifiers. The pulse shape is varied by setting a bias voltage on each in a chain of MESFETS with a 200 ps temporal resolution. The electrical pulse then drives an integrated electro-optic modulator similar to what is on Beamlet. Pulse shapes 22 and 25, used on Nova, have been generated by this design. There is no fundamental barrier to making such a pulse generator for use on the National Ignition Facility. In fact, the longer time scales on the NIF pulse will ease the high speed requirements of the pulse shape generator allowing the use of less expensive components. The next step will be to build a prototype circuit for initial testing on Beamlet and Nova.

  1. Submerged Medium Voltage Cable Systems at Nuclear Power Plants...

    Office of Scientific and Technical Information (OSTI)

    Submerged Medium Voltage Cable Systems at Nuclear Power Plants: A Review of Research Efforts Relevant to Aging Mechanisms and Condition Monitoring. Re-direct Destination: In a...

  2. Mitigating Voltage Fade in Cathode Materials by Improving the...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Fade in Cathode Materials by Improving the Atomic Level Uniformity of Elemental Distribution. Mitigating Voltage Fade in Cathode Materials by Improving the Atomic Level...

  3. Nanoscale Morphological and Chemical Changes of High Voltage...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Nanoscale Morphological and Chemical Changes of High Voltage Lithium-Manganese Rich NMC Composite Cathodes with Cycling Friday, August 29, 2014 Renewable energy is critical for the...

  4. active capacitive voltage: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Khoman 5 Discrete Steps in the Capacitance-Voltage Characteristics of GaInNGaN Light Emitting Diode Structures Materials Science Websites Summary: Discrete Steps in the...

  5. Sharp interface and voltage conservation in the ... - Purdue University

    E-Print Network [OSTI]

    2007-07-14T23:59:59.000Z

    electrical wave is anisotropic, and cardiac tissue is made up of cells with heteroge- ... fact that voltage gain or loss due to numerical inaccuracies in the spatial ...

  6. Triple voltage dc-to-dc converter and method

    DOE Patents [OSTI]

    Su, Gui-Jia (Knoxville, TN)

    2008-08-05T23:59:59.000Z

    A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.

  7. auxiliary voltage converter: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Voltage Switching inverter working at 20 kHz and an output stage (high frequency transformers, Schottky rectifi ers and output filter... Jrgensen, H E; Dupaquier, A;...

  8. Electrochemical Characterization of Voltage Fade in LMR-NMC cells

    Broader source: Energy.gov (indexed) [DOE]

    the extent of Voltage Fade December 2012 * Establish baseline data on standard materials to facilitate comparison of various datasets March 2013 * Obtain data to determine...

  9. Electrochemical Characterization of Voltage Fade in LMR-NMC cells...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Electrochemical Characterization of Voltage Fade in LMR-NMC cells 2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer...

  10. Evaluation of electropolished stainless steel electrodes for use in DC high voltage photoelectron guns

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    BastaniNejad, Mahzad; Elmustafa, Abdelmageed A.; Forman, Eric; Covert, Steven; Hansknecht, John; Hernandez-Garcia, Carlos; Poelker, Matthew; Das, Lopa; Kelley, Michael; Williams, Phillip

    2015-07-01T23:59:59.000Z

    DC high voltage photoelectron guns are used to produce polarized electron beams for accelerator-based nuclear and high-energy physics research. Low-level field emission (~nA) from the cathode electrode degrades the vacuum within the photogun and reduces the photoelectron yield of the delicate GaAs-based photocathode used to produce the electron beams. High-level field emission (>?A) can cause significant damage the photogun. To minimize field emission, stainless steel electrodes are typically diamond-paste polished, a labor-intensive process often yielding field emission performance with a high degree of variability, sample to sample. As an alternative approach and as comparative study, the performance of electrodes electropolishedmore »by conventional commercially available methods is presented. Our observations indicate the electropolished electrodes exhibited less field emission upon the initial application of high voltage, but showed less improvement with gas conditioning compared to the diamond-paste polished electrodes. In contrast, the diamond-paste polished electrodes responded favorably to gas conditioning, and ultimately reached higher voltages and field strengths without field emission, compared to electrodes that were only electropolished. The best performing electrode was one that was both diamond-paste polished and electropolished, reaching a field strength of 18.7 MV/m while generating less than 100 pA of field emission. The speculate that the combined processes were the most effective at reducing both large and small scale topography. However, surface science evaluation indicates topography cannot be the only relevant parameter when it comes to predicting field emission performance.« less

  11. Red Algae Respond to Waves: Morphological and Mechanical Variation in Mastocarpus papillatus Along

    E-Print Network [OSTI]

    Denny, Mark

    Red Algae Respond to Waves: Morphological and Mechanical Variation in Mastocarpus papillatus Along Grove, California, 93950 Abstract. Intertidal algae are exposed to the potentially severe drag forces generated by crashing waves, and several species of brown algae respond, in part, by varying the strength

  12. Voltage multi-stability in distribution grids with power flow reversal

    E-Print Network [OSTI]

    Hung D. Nguyen; Konstantin Turitsyn

    2014-07-08T23:59:59.000Z

    High levels of penetration of distributed generation and aggressive reactive power compensation with modern power electronics may result in the reversal of active and reactive power flows in future distribution grids. The voltage stability of these operating conditions may be very different from the more traditional power consumption regime. We study the stability characteristics of distribution networks with reversed power flow. After introducing a universal algebraic approach to characterize all the solutions of the power flow equations, we show that new solutions appear in the reversed power flow regime even in the simplest three bus systems. We show that the some of these solutions are stable and the system may exhibit a phenomenon of multistability, where multiple stable equilibria co-exist at the given set of parameters, and the system may converge to an undesirable equilibrium after a disturbance. These predictions are validated with dynamic simulations of two different systems. Under certain conditions the new states are viable and may be characterized by relatively high voltages. Possible approaches towards reactive power/voltage regulation as well as permissible distributed generation capacity in future power systems are proposed and discussed in the end of the paper.

  13. Regulation XVIII: GENERAL REGULATIONS FOR HIGHER DEGREES,

    E-Print Network [OSTI]

    Regulation XVIII: GENERAL REGULATIONS FOR HIGHER DEGREES, POSTGRADUATE DIPLOMAS AND POSTGRADUATE CERTIFICATES SCOPE OF THESE REGULATIONS 1. These Regulations apply to the Degree of PhD in all Faculties in all Faculties Postgraduate Certificates in all Faculties. 2. These Regulations are subject

  14. Regulation 28: Library REGULATION 28: LIBRARY

    E-Print Network [OSTI]

    Sussex, University of

    Regulation 28: Library 180 REGULATION 28: LIBRARY The purpose of this Regulation is to safeguard the common interests of all Library users. All persons are admitted on the understanding that they have read and agreed to observe the Library Regulations. Breach of this Regulation could result in membership being

  15. Measurement of high voltage using Rutherford backscattering spectrometry

    E-Print Network [OSTI]

    Abrego, Celestino Pete

    2007-04-25T23:59:59.000Z

    A novel variation of Rutherford Backscattering Spectrometry (RBS) has been utilized to measure a high voltage collected on an aluminum target by Direct Energy Conversion. The maximum high voltage on the target was measured to be 97.5 kV +/- 2 k...

  16. A LOW-VOLTAGE TEMPERATURE-STABLE MICROMECHANICAL PIEZOELECTRIC OSCILLATOR

    E-Print Network [OSTI]

    Ayazi, Farrokh

    A LOW-VOLTAGE TEMPERATURE-STABLE MICROMECHANICAL PIEZOELECTRIC OSCILLATOR Reza Abdolvand, Hossein polarization voltages (5-20V) for operation, which complicates the design of the oscillator circuit in today reference oscillator that utilizes a temperature-stable thin- film piezoelectric-on-silicon resonator

  17. Control and Protection Cooperation Strategy for Voltage Instability

    E-Print Network [OSTI]

    Chen, Zhe

    to be transmitted in the weak linked system. On the other hand, the backup protection relays on the transmissionControl and Protection Cooperation Strategy for Voltage Instability Zhou Liu Aalborg University zli are caused by unexpected backup relay operations due to low voltage or overload state caused by post fault

  18. Voltage sensor with fiber Fabry-Perot interferometer

    E-Print Network [OSTI]

    Wann, Been-Huey

    1992-01-01T23:59:59.000Z

    INTRODUCTION. Page II RESEARCH DESCRIPTION. . . A. Optical Fiber Fabry-Perot Interferometer. . . . . B. Piezoelectricity. . C. Modulating Point in 60 Hz Voltage Measurement. . . . . . D. Temperature Control Circuit . . . . 18 . . . 26 III EXPERIMENTAL... PROCEDURES AND RESULTS. . . . . . A. Fabrication of the Optical Fiber Fabry-Perot Interferometer B. Selection of Piezoelectric Materials. C. Implementation of Temperature Control Circuit. . . . D. Experiments of Optical Fiber Voltage Sensor...

  19. Analysis of Voltage Rise Effect on Distribution Network with Distributed

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Analysis of Voltage Rise Effect on Distribution Network with Distributed Generation M. A. Mahmud.hossain@adfa.edu.au, and H.Pota@adfa.edu.au). Abstract: Connections of distributed generation (DG) in distribution networks are increasing. These connections of distributed generation cause voltage rise in the distribution network

  20. CompilerDirected Dynamic Voltage Scaling Based on Program Regions

    E-Print Network [OSTI]

    Kremer, Ulrich

    Compiler­Directed Dynamic Voltage Scaling Based on Program Regions Chung­Hsing Hsu and Ulrich using dynamic voltage scaling. The compiler identifies pro­ gram regions where the CPU can be slowed down without resulting in a significant overall performance loss. For such regions the lowest CPU

  1. Power Grid Voltage Integrity Verification Department of ECE

    E-Print Network [OSTI]

    Najm, Farid N.

    Power Grid Voltage Integrity Verification Maha Nizam Department of ECE University of Toronto devgan@magma-da.com ABSTRACT Full-chip verification requires one to check if the power grid is safe, i.e., if the voltage drop on the grid does not exceed a cer- tain threshold. The traditional simulation-based solution

  2. Low-voltage gas-discharge device

    DOE Patents [OSTI]

    Kovarik, V.J.; Hershcovitch, A.; Prelec, K.

    1982-06-08T23:59:59.000Z

    An electronic device of the type wherein current flow is conducted by an ionized gas comprising a cathode of the type heated by ionic bombardment, an anode, means for maintaining a predetermined pressure in the region between the anode and the cathode and means for maintaining a field in the region is described. The field, which is preferably a combined magnetic and electric field, is oriented so that the mean distance traveled by electrons before reaching the anode is increased. Because of this increased distance traveled electrons moving to the anode will ionize a large number of gas atoms, thus reducing the voltage necessary to initiate gas breakdown. In a preferred embodiment the anode is a main hollow cathode and the cathode is a smaller igniter hollow cathode located within and coaxial with the main hollow cathode. An axial magnetic field is provided in the region between the hollow cathodes in order to facilitate gas breakdown in that region and initiate plasma discharge from the main hollow cathode.

  3. Spark-safe low-voltage detonator

    DOE Patents [OSTI]

    Lieberman, Morton L. (Albuquerque, NM)

    1989-01-01T23:59:59.000Z

    A column of explosive in a low-voltage detonator which makes it spark-safe ncludes an organic secondary explosive charge of HMX in the form of a thin pad disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to an electrical ignition device at one end of the bore. The pad of secondary charge has an axial thickness within the range of twenty to thirty percent of its diameter. The explosive column also includes a first explosive charge of CP disposed in the housing bore in the ignition region of the explosive column next to the secondary charge pad on a side opposite from the ignition device. The first CP charge is loaded under sufficient pressure, 25 to 40 kpsi, to provide mechanical confinement of the pad of secondary charge and physical coupling thereof with the ignition device. The explosive column further includes a second explosive charge of CP disposed in the housing bore in a transition region of the explosive column next to the first CP charge on a side opposite from the pad of secondary charge. The second CP charge is loaded under sufficient pressure, about 10 kpsi, to allow occurrence of DDT. The first explosive CP charge has an axial thickness within the range of twenty to thirty percent of its diameter, whereas the second explosive CP charge contains a series of increments (nominally 4) each of which has an axial thickness-to-diameter ratio of one to two.

  4. Bonfire-safe low-voltage detonator

    DOE Patents [OSTI]

    Lieberman, Morton L. (Albuquerque, NM)

    1990-01-01T23:59:59.000Z

    A column of explosive in a low-voltage detonator which makes it bonfire-safe includes a first layer of an explosive charge of CP, or a primary explosive, and a second layer of a secondary organic explosive charge, such as PETN, which has a degradation temperature lower than the autoignition temperature of the CP or primary explosives. The first layer is composed of a pair of increments disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to and in contact with an electrical ignition device at one end of the bore. The second layer is composed of a plurality of increments disposed in the housing bore in a transition region of the explosive column next to and in contact with the first layer on a side opposite from the ignition device. The first layer is loaded under a sufficient high pressure, 25 to 40 kpsi, to achieve ignition, whereas the second layer is loaded under a sufficient low pressure, about 10 kpsi, to allow occurrence of DDT. Each increment of the first and second layers has an axial length-to-diameter ratio of one-half.

  5. Bonfire-safe low-voltage detonator

    DOE Patents [OSTI]

    Lieberman, M.L.

    1988-07-01T23:59:59.000Z

    A column of explosive in a low-voltage detonator which makes it bonfire-safe includes a first layer of an explosive charge of CP, or a primary explosive, and a second layer of a secondary organic explosive charge, such as PETN, which has a degradation temperature lower than the autoignition temperature of the CP or primary explosives. The first layer is composed of a pair of increments disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to and in contact with an electrical ignition device at one end of the bore. The second layer is composed of a plurality of increments disposed in the housing bore in a transition region of the explosive column next to and in contact with the first layer on a side opposite from the ignition device. The first layer is loaded under a sufficient high pressure, 25 to 40 kpsi, to achieve ignition, whereas the second layer is loaded under a sufficient low pressure, about 10 kpsi, to allow occurrence of DDT. Each increment of the first and second layers has an axial length-to-diameter ratio of one-half. 2 figs.

  6. Integrated, Low Voltage, DynamicallyIntegrated, Low Voltage, Dynamically Adaptive BuckAdaptive Buck--Boost ConverterBoost Converter

    E-Print Network [OSTI]

    Rincon-Mora, Gabriel A.

    Improvement in battery life Low voltage Single cell operation (Li-ion/NiCd/NiMH/Fuel Cell) Integrated frequency 1 MHz ± 20% Closed-loop bandwidth 50 kHz 1-dB step change response time 20 µsec Full-load efficiency 90 % Control signal Output voltageTpower_change Tresponse Time 1 dB Typical transient response

  7. Panel Session: Optimization Techniques in Voltage Collapse Analysis," IEEE PES Summer Meeting, San Diego, July 14, 1998. Applications of Optimization to Voltage Collapse Analysis

    E-Print Network [OSTI]

    Cañizares, Claudio A.

    Panel Session: Optimization Techniques in Voltage Collapse Analysis," IEEE PES Summer Meeting, San Diego, July 14, 1998. Applications of Optimization to Voltage Collapse Analysis Claudio A. Ca|Thispaper describesseveralapplica- tions of optimization for voltage stability analysis VSA of power systems. Voltage stability prob

  8. Electronic high voltage generator with a high temperature superconducting coil

    SciTech Connect (OSTI)

    Jin, J.X.; Liu, H.K.; Dou, S.X. [Univ. of Wollongong (Australia)] [and others

    1996-12-31T23:59:59.000Z

    A novel method for generating high voltages from a low voltage DC source, by using a capacitor and inductor in a R, L, C resonant circuit has been developed with the consideration of using a high temperature superconducting (HTS) coil. To generate high voltages the polarity of a low voltage battery source is reversed each half resonant cycle, the control being achieved by an electronic switch. Resistance in the circuit limits the voltages that can be built up. By replacing a copper winding inductor with another inductor which has a HTS winding, the magnitude of achievable voltages is substantially increased. A (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10+x} multifilament HTS wire is considered in this work to make the superconducting inductor. The high voltages generated are not capable of supplying low impedance loads, however, possible applications of the generator include electrical partial discharge testing and insulation resistance testing. It could also be used as a testing method for the HTS itself with respect to the critical current and AC loss measurement.

  9. Electro-optic voltage sensor with beam splitting

    DOE Patents [OSTI]

    Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID)

    2002-01-01T23:59:59.000Z

    The invention is a miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware typically found in the prior art. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

  10. Electro-optic voltage sensor with Multiple Beam Splitting

    DOE Patents [OSTI]

    Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID)

    2000-01-01T23:59:59.000Z

    A miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

  11. Guide on Preventing and Responding to All Forms of Violence in the Workplace

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2015-04-22T23:59:59.000Z

    This guide is a broad overview of the basic tools for development of site specific procedures for responding to workplace violence. Supports implementation of DOE P 444.1. Does not cancel other directives.

  12. Washington and Lee University Guidelines for Responding to Information Security Breaches

    E-Print Network [OSTI]

    Marsh, David

    Washington and Lee University Guidelines for Responding to Information Security Breaches Notifications 1. As further detailed in the university's Guidelines for Reporting Information Security Breaches regarding an actual or suspected data breach should contact: i. the university's Information Security

  13. Look at this: the neural correlates of initiating and responding to bids for joint attention

    E-Print Network [OSTI]

    Redcay, Elizabeth

    When engaging in joint attention, one person directs another person's attention to an object (Initiating Joint Attention, IJA), and the second person's attention follows (Responding to Joint Attention, RJA). As such, joint ...

  14. n 1980, Congress responded to a growing problem of abandoned factories and other polluted sites by

    E-Print Network [OSTI]

    Short, Daniel

    n 1980, Congress responded to a growing problem of abandoned factories and other polluted sites to be investigated. The larger sites were for- mer mine sites and ore processing facilities. One of the larger mine

  15. Modelling regulations Completing an incomplete regulation

    E-Print Network [OSTI]

    van der Torre, Leon

    Objectives Modelling regulations Completing an incomplete regulation Examples Discussion Consistency and Completeness of Regulations Laurence Cholvy1 St´ephanie Roussel1,2 1ONERA Centre de Toulouse 2ISAE, Toulouse NorMAS 2008, Luxembourg, July 2008 cholvy Consistency and Completeness of Regulations

  16. Spark-safe low-voltage detonator

    DOE Patents [OSTI]

    Lieberman, M.L.

    1988-07-01T23:59:59.000Z

    A column of explosive in a low-voltage detonator which makes it spark-safe includes an organic secondary explosive charge of HMX in the form of a thin pad disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to an electrical ignition device at one end of the bore. The pad of secondary charge has an axial thickness within the range of twenty to thirty percent of its diameter. The explosive column also includes a first explosive charge of CP disposed in the housing bore in the ignition region of the explosive column next to the secondary charge pad on a side opposite from the ignition device. The first CP charge is loaded under sufficient pressure, 25 to 40 kpsi, to provide mechanical confinement of the pad of secondary charge and physical coupling thereof with the ignition device. The explosive column further includes a second explosive charge of CP disposed in the housing bore in a transition region of the explosive column next to the first CP charge on a side opposite from the pad of secondary charge. The second CP charge is loaded under sufficient pressure, about 10 kpsi, to allow occurrence of DDT. The first explosive CP charge has an axial thickness within the range of twenty to thirty percent of its diameter, whereas the second explosive CP charge contains a series of increments (nominally 4), each of which has an axial thickness-to-diameter ratio of one to two. 2 figs.

  17. Imagery, affect, and the embodied mind: implications for reading and responding to literature

    E-Print Network [OSTI]

    Krasny, Karen A.

    2006-04-12T23:59:59.000Z

    IMAGERY, AFFECT, AND THE EMBODIED MIND: IMPLICATIONS FOR READING AND RESPONDING TO LITERATURE A Dissertation by KAREN A. KRASNY Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment... of the requirements for the degree of DOCTOR OF PHILOSOPHY December 2004 Major Subject: Curriculum & Instruction IMAGERY, AFFECT, AND THE EMBODIED MIND: IMPLICATIONS FOR READING AND RESPONDING TO LITERATURE A Dissertation by KAREN A. KRASNY...

  18. Optically triggered high voltage switch network and method for switching a high voltage

    DOE Patents [OSTI]

    El-Sharkawi, Mohamed A. (Renton, WA); Andexler, George (Everett, WA); Silberkleit, Lee I. (Mountlake Terrace, WA)

    1993-01-19T23:59:59.000Z

    An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

  19. Secondary Control for Voltage Unbalance Compensation in an Islanded Microgrid

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    coupling (PCC). Unbalance compensation is achieved by proper control of distributed generators (DGs unbalance. Keywords-distributed generation; microgrid; secondary control; voltage unbalance compensation I. INTRODUCTION Distributed Generators (DGs) may be connected individually to the utility grid or be integrated

  20. Time varying voltage combustion control and diagnostics sensor

    DOE Patents [OSTI]

    Chorpening, Benjamin T. (Morgantown, WV); Thornton, Jimmy D. (Morgantown, WV); Huckaby, E. David (Morgantown, WV); Fincham, William (Fairmont, WV)

    2011-04-19T23:59:59.000Z

    A time-varying voltage is applied to an electrode, or a pair of electrodes, of a sensor installed in a fuel nozzle disposed adjacent the combustion zone of a continuous combustion system, such as of the gas turbine engine type. The time-varying voltage induces a time-varying current in the flame which is measured and used to determine flame capacitance using AC electrical circuit analysis. Flame capacitance is used to accurately determine the position of the flame from the sensor and the fuel/air ratio. The fuel and/or air flow rate (s) is/are then adjusted to provide reduced flame instability problems such as flashback, combustion dynamics and lean blowout, as well as reduced emissions. The time-varying voltage may be an alternating voltage and the time-varying current may be an alternating current.

  1. Planar LTCC transformers for high voltage flyback converters: Part II.

    SciTech Connect (OSTI)

    Schofield, Daryl (NASCENTechnology, Inc., Watertown, SD); Schare, Joshua M., Ph.D.; Slama, George (NASCENTechnology, Inc., Watertown, SD); Abel, David (NASCENTechnology, Inc., Watertown, SD)

    2009-02-01T23:59:59.000Z

    This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.

  2. Multilevel cascade voltage source inverter with seperate DC sources

    DOE Patents [OSTI]

    Peng, Fang Zheng (Knoxville, TN); Lai, Jih-Sheng (Blacksburg, VA)

    2002-01-01T23:59:59.000Z

    A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

  3. High-voltage air-core pulse transformers

    SciTech Connect (OSTI)

    Rohwein, G. J.

    1981-01-01T23:59:59.000Z

    General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

  4. IEEE 342 Node Low Voltage Networked Test System

    SciTech Connect (OSTI)

    Schneider, Kevin P.; Phanivong, Phillippe K.; Lacroix, Jean-Sebastian

    2014-07-31T23:59:59.000Z

    The IEEE Distribution Test Feeders provide a benchmark for new algorithms to the distribution analyses community. The low voltage network test feeder represents a moderate size urban system that is unbalanced and highly networked. This is the first distribution test feeder developed by the IEEE that contains unbalanced networked components. The 342 node Low Voltage Networked Test System includes many elements that may be found in a networked system: multiple 13.2kV primary feeders, network protectors, a 120/208V grid network, and multiple 277/480V spot networks. This paper presents a brief review of the history of low voltage networks and how they evolved into the modern systems. This paper will then present a description of the 342 Node IEEE Low Voltage Network Test System and power flow results.

  5. Design & Fabrication of a High-Voltage Photovoltaic Cell

    SciTech Connect (OSTI)

    Felder, Jennifer; /North Carolina State U. /SLAC

    2012-09-05T23:59:59.000Z

    Silicon photovoltaic (PV) cells are alternative energy sources that are important in sustainable power generation. Currently, applications of PV cells are limited by the low output voltage and somewhat low efficiency of such devices. In light of this fact, this project investigates the possibility of fabricating high-voltage PV cells on float-zone silicon wafers having output voltages ranging from 50 V to 2000 V. Three designs with different geometries of diffusion layers were simulated and compared in terms of metal coverage, recombination, built-in potential, and conduction current density. One design was then chosen and optimized to be implemented in the final device design. The results of the simulation serve as a feasibility test for the design concept and provide supportive evidence of the effectiveness of silicon PV cells as high-voltage power supplies.

  6. Unravelling the Performance Degradation Mechanisms in High-voltage...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Unravelling the Performance Degradation Mechanisms in High-voltage Lithium-ion Battery Composite Oxide Electrodes Apr 11 2014 02:00 PM - 03:00 PM Debasish Mohanty, ORNL, Oak Ridge...

  7. Voltage Dependent Charge Storage Modes and Capacity in Subnanometer Pores

    SciTech Connect (OSTI)

    Qiao, Rui [Clemson University; Meunier, V. [Rensselaer Polytechnic Institute (RPI); Huang, Jingsong [ORNL; Wu, Peng [ORNL; Sumpter, Bobby G [ORNL

    2012-01-01T23:59:59.000Z

    Using molecular dynamics simulations, we show that charge storage in subnanometer pores follows a distinct voltage-dependent behavior. Specifically, at lower voltages, charge storage is achieved by swapping co-ions in the pore with counterions in the bulk electrolyte. As voltage increases, further charge storage is due mainly to the removal of co-ions from the pore, leading to a capacitance increase. The capacitance eventually reaches a maximum when all co-ions are expelled from the pore. At even higher electrode voltages, additional charge storage is realized by counterion insertion into the pore, accompanied by a reduction of capacitance. The molecular mechanisms of these observations are elucidated and provide useful insight for optimizing energy storage based on supercapacitors.

  8. High frequency AC power converter for low voltage circuits

    E-Print Network [OSTI]

    Salazar, Nathaniel Jay Tobias

    2012-01-01T23:59:59.000Z

    This thesis presents a novel AC power delivery architecture that is suitable for VHF frequency (50-100MHz) polyphase AC/DC power conversion in low voltage integrated circuits. A complete AC power delivery architecture was ...

  9. Modeling the operating voltage of liquid metal battery cells

    E-Print Network [OSTI]

    Newhouse, Jocelyn Marie

    2014-01-01T23:59:59.000Z

    A one-dimensional, integrative model of the voltage during liquid metal battery operation has been developed to enhance the understanding of performance at the cell level. Two liquid metal batteries were studied: Mg-Sb for ...

  10. IMPACT OF DYNAMIC VOLTAGE SCALING (DVS) ON CIRCUIT OPTIMIZATION

    E-Print Network [OSTI]

    Esquit Hernandez, Carlos A.

    2010-01-16T23:59:59.000Z

    Circuit designers perform optimization procedures targeting speed and power during the design of a circuit. Gate sizing can be applied to optimize for speed, while Dual-VT and Dynamic Voltage Scaling (DVS) can be applied to optimize for leakage...

  11. IMPACT OF DYNAMIC VOLTAGE SCALING (DVS) ON CIRCUIT OPTIMIZATION 

    E-Print Network [OSTI]

    Esquit Hernandez, Carlos A.

    2010-01-16T23:59:59.000Z

    Circuit designers perform optimization procedures targeting speed and power during the design of a circuit. Gate sizing can be applied to optimize for speed, while Dual-VT and Dynamic Voltage Scaling (DVS) can be applied ...

  12. Strongly nonlinear dynamics of electrolytes in large ac voltages

    E-Print Network [OSTI]

    Hojgaard Olesen, Laurits

    We study the response of a model microelectrochemical cell to a large ac voltage of frequency comparable to the inverse cell relaxation time. To bring out the basic physics, we consider the simplest possible model of a ...

  13. Multilevel cascade voltage source inverter with seperate DC sources

    DOE Patents [OSTI]

    Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

    1997-01-01T23:59:59.000Z

    A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

  14. Multilevel cascade voltage source inverter with seperate DC sources

    DOE Patents [OSTI]

    Peng, Fang Zheng; Lai, Jih-Sheng

    2001-04-03T23:59:59.000Z

    A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

  15. Multilevel cascade voltage source inverter with separate DC sources

    DOE Patents [OSTI]

    Peng, F.Z.; Lai, J.S.

    1997-06-24T23:59:59.000Z

    A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations. 15 figs.

  16. Prediction of flashover voltage of non-ceramic insulators under contaminated conditions

    E-Print Network [OSTI]

    Prediction of flashover voltage of non-ceramic insulators under contaminated conditions S ABSTRACT This paper describes the development of a theoretical model to predict flashover voltage

  17. RESPONDENT INFORMATION

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for On-Highway4,1,50022,3,,,,6,1,9,1,50022,3,,,,6,1,Decade Year-0E (2001) - HouseholdshortEIA-782A andS F

  18. first responders

    National Nuclear Security Administration (NNSA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilA Approved:AdministrationAnalysisDarby Dietrich5 |0/%2A0/%2A en6/%2A

  19. Measuring Helical FCG Voltage with an Electric Field Antenna

    SciTech Connect (OSTI)

    White, A D; Anderson, R A; Javedani, J B; Reisman, D B; Goerz, D A; Ferriera, A J; Speer, R D

    2011-08-01T23:59:59.000Z

    A method of measuring the voltage produced by a helical explosive flux compression generator using a remote electric field antenna is described in detail. The diagnostic has been successfully implemented on several experiments. Measured data from the diagnostic compare favorably with voltages predicted using the code CAGEN, validating our predictive modeling tools. The measured data is important to understanding generator performance, and is measured with a low-risk, minimally intrusive approach.

  20. Image-line voltage controlled oscillators and grating antennas

    E-Print Network [OSTI]

    Kirk, Alexander MacDonald

    1991-01-01T23:59:59.000Z

    IMAGE-LINE VOLTAGE CONTROLLED OSCILLATORS AND GRATING ANTENNAS A Thesis by ALEXANDER MacDONALD KIRK Submitted to the Office of Graduate Studies of Texas ABM University in partial fulfillment of the requirements for the degree of MASTER... OF SCIENCE May 1991 Major Subject: Electrical Engineering IMAGE-LINE VOLTAGE CONTROLLED OSCILLATORS AND GRATING ANTENNAS A Thesis by ALEXANDER MacDONALD KIRK Approved as to style and content by: Kai Chang (Chair of Committee) Robert D. Nevels...

  1. Sinusoidal voltage controlled oscillators using operational transconductance amplifiers

    E-Print Network [OSTI]

    Hoyle Passano, Javier Joaquin

    1985-01-01T23:59:59.000Z

    SINUSOIDAI. VOLTAGE CONTROLLED OSCILLATORS I. SING OPERATIONAL TRANSCONDUCTANCE AMPLIFIERS A Thesis JAVIFB . IOAQUIN HOYI. K I'ASSANO Suhndtted to the Graduate College ol' 'I'exes A8cM University in partial fulfillment of the requirement... for the degree of MASTER OF SCIENCE May 1985 Major Subject: Electrical Engineering SINUSOIDAL VOLTAGE CONTROLLED OSCILLATORS USING OPERATIONAI, TRANSCONDUCTANCE AMPLIFIERS A Thesis by JAVIER JOAQUIN HOYLE PASSANO Approved as to style and content by: o...

  2. Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells

    DOE Patents [OSTI]

    Delnick, F.M.

    1993-04-13T23:59:59.000Z

    Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl[sub 2] and SO[sub 2]Cl[sub 2] electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl[sub 2] and Li/SO[sub 2]Cl[sub 2] batteries.

  3. Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells

    DOE Patents [OSTI]

    Delnick, Frank M. (Albuquerque, NM)

    1993-01-01T23:59:59.000Z

    Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl.sub.2 and SO.sub.2 Cl.sub.2 electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl.sub.2 and Li/SO.sub.2 Cl.sub.2 batteries.

  4. Design of programmable, low power, low dropout voltage regulators for portable applications

    E-Print Network [OSTI]

    Islas Ohlmaier, Abraham

    2007-04-25T23:59:59.000Z

    -Martinez Committee Members, Aydin Karsilayan Karen L. Butler-Purry Rainer Fink Head of Department, Costas Georghiades December 2005 Major Subject: Electrical Engineering iii ABSTRACT Design of Programmable, Low Power, Low...

  5. Circadian Regulation of L-Type Voltage-Gated Calcium Channels in Avian Retina 

    E-Print Network [OSTI]

    Huang, Chia-Yu

    2014-11-25T23:59:59.000Z

    The circadian clock is an endogenous time-keeping mechanism that allows an organism to synchronize itself with external time cues and prepares the organism to anticipate upcoming environmental changes on a daily basis. The ...

  6. A capacitor-less low drop-out voltage regulator with fast transient response

    E-Print Network [OSTI]

    Milliken, Robert Jon

    2006-04-12T23:59:59.000Z

    MILLIKEN Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE Approved by: Co-Chairs of Committee, Jose Silva-Martinez Edgar Sanchez... with Fast Transient Response. (December 2005) Robert Jon Milliken, B.S., Iowa State University Co-Chairs of Advisory Committee: Dr. Jose Silva-Martinez Dr. Edgar Sanchez-Sinencio Power management has had an ever increasing role in the present...

  7. Circadian Regulation of L-Type Voltage-Gated Calcium Channels in Avian Retina

    E-Print Network [OSTI]

    Huang, Chia-Yu

    2014-11-25T23:59:59.000Z

    (mTORC1), and AMP-activated protein kinase (AMPK). The activities of the protein phosphatase calcineurin, as well as the protein kinase mTORC1 exhibited circadian oscillation with their activities higher at night than during the day, while...

  8. Digital Architecture for Driving Large LED Arrays with Dynamic Bus Voltage Regulation and Phase Shifted PWM

    E-Print Network [OSTI]

    Emitting Diodes (HB-LEDs) with improved system efficiency and reduced EMI. Key advantages are achieved - This paper introduces a digital architecture suitable for driving a large number of High Brightness Light

  9. Power Supply Rejection Improvement Techniques In Low Drop-Out Voltage Regulators 

    E-Print Network [OSTI]

    Ganta, Saikrishna

    2011-10-21T23:59:59.000Z

    Efficency Load q DD I V P I I V ? ? (1.4) Typically the quiescent current of LDO is designed to be less than hundred micro amperes, while the maximum load current can be few hundreds of milliamperes, thus... at maximum loading conditions power efficiency is given by out Efficency DD V P V ? (1.5) Thus for maximum loading conditions power efficiency...

  10. Peak Power Bi-directional Transfer From High Speed Flywheel to Electrical Regulated Bus Voltage System

    E-Print Network [OSTI]

    Szabados, Barna

    life cycle. A reduced life cycle will translate into high maintenance costs since the batteries have devices capable of a minimum power of 400 W/kg, energy of 200 Wh/kg, a life cycle of 2500 at a cost vehicle during both acceleration and regenerative braking. The life cycle of the electric vehicle

  11. Environmental Regulation Impacts on Eastern Interconnection Performance

    SciTech Connect (OSTI)

    Markham, Penn N [ORNL; Liu, Yilu [ORNL; Young II, Marcus Aaron [ORNL

    2013-07-01T23:59:59.000Z

    In the United States, recent environmental regulations will likely result in the removal of nearly 30 GW of oil and coal-fired generation from the power grid, mostly in the Eastern Interconnection (EI). The effects of this transition on voltage stability and transmission line flows have previously not been studied from a system-wide perspective. This report discusses the results of power flow studies designed to simulate the evolution of the EI over the next few years as traditional generation sources are replaced with environmentally friendlier ones such as natural gas and wind.

  12. Coupling between the voltage-sensing and pore domains in a voltage-gated potassium channel

    E-Print Network [OSTI]

    White, Stephen

    -dependent potassium (Kv), sodium (Nav), and calcium channels open and close in response to changes in transmembrane (TM) potential, thus regulating cell excitability by controlling ion flow across the membrane, but it is generally accepted that, when the channel is closed, the VSDs adopt a "down-state" configuration in which

  13. High power impulse magnetron sputtering: Current-voltage-time characteristics indicate the onset of sustained self-sputtering

    E-Print Network [OSTI]

    Anders, Andre; Andersson, Joakim; Ehiasarian, Arutiun

    2008-01-01T23:59:59.000Z

    target voltage starts to slightly droop for higher voltages,1000 V, the actual voltage droops and shows less stability.see a large voltage droop, especially at high current). We

  14. Data for First Responder Use of Photoionization Detectors for Vapor Chemical Constituents

    SciTech Connect (OSTI)

    Keith A. Daum; Matthew G. Watrous; M. Dean Neptune; Daniel I. Michael; Kevin J. Hull; Joseph D. Evans

    2006-11-01T23:59:59.000Z

    First responders need appropriate measurement technologies for evaluating incident scenes. This report provides information about photoionization detectors (PIDs), obtained from manufacturers and independent laboratory tests, and the use of PIDs by first responders, obtained from incident commanders in the United States and Canada. PIDs are valued for their relatively low cost, light weight, rapid detection response, and ease of use. However, it is clear that further efforts are needed to provide suitable instruments and decision tools to incident commanders and first responders for assessing potential hazardous chemical releases. Information provided in this report indicates that PIDs should always be part of a decision-making context in which other qualitative and more definitive tests and instruments are used to confirm a finding. Possible amelioratory actions ranging from quick and relatively easy fixes to those requiring significant additional effort are outlined in the report.

  15. Overview of Hazard Assessment and Emergency Planning Software of Use to RN First Responders

    SciTech Connect (OSTI)

    Waller, E; Millage, K; Blakely, W F; Ross, J A; Mercier, J R; Sandgren, D J; Levine, I H; Dickerson, W E; Nemhauser, J B; Nasstrom, J S; Sugiyama, G; Homann, S; Buddemeier, B R; Curling, C A; Disraelly, D S

    2008-08-26T23:59:59.000Z

    There are numerous software tools available for field deployment, reach-back, training and planning use in the event of a radiological or nuclear (RN) terrorist event. Specialized software tools used by CBRNe responders can increase information available and the speed and accuracy of the response, thereby ensuring that radiation doses to responders, receivers, and the general public are kept as low as reasonably achievable. Software designed to provide health care providers with assistance in selecting appropriate countermeasures or therapeutic interventions in a timely fashion can improve the potential for positive patient outcome. This paper reviews various software applications of relevance to radiological and nuclear (RN) events that are currently in use by first responders, emergency planners, medical receivers, and criminal investigators.

  16. California Energy Commission REGULATIONS

    E-Print Network [OSTI]

    California Energy Commission REGULATIONS FINAL STATEMENT OF REASONS ENFORCEMENT PROCEDURES by Government Code section 11346.9(a) for the California Energy Commission (Energy Commission) regulations 399.30 (l) directs the Energy Commission to adopt regulations specifying procedures

  17. California Energy Commission REGULATIONS

    E-Print Network [OSTI]

    California Energy Commission REGULATIONS NONRESIDENTIAL BUILDING ENERGY Disclosure Program California Code of Regulations Title 20. Public Utilities and Energy Division 2. State USE DISCLOSURE PROGRAM California Code of Regulations, Title 20, Division 2

  18. The Sestrins Interact with GATOR2 to Negatively Regulate the Amino-Acid-Sensing Pathway Upstream of mTORC1

    E-Print Network [OSTI]

    Chantranupong, Lynne

    The mechanistic target of rapamycin complex 1 (mTORC1) kinase is a major regulator of cell growth that responds to numerous environmental cues. A key input is amino acids, which act through the heterodimeric Rag GTPases ...

  19. Forest Road Building Regulations

    Broader source: Energy.gov [DOE]

    The Wisconsin Department of Natural Resources has regulations for building a forest road, if development requires one. Regulations include zoning ordinances and permits for stream crossing, grading...

  20. Concept of Quasi-Capacitive Tapping of Bipolar Voltage-Controlled Oscillators

    E-Print Network [OSTI]

    Serdijn, Wouter A.

    Concept of Quasi-Capacitive Tapping of Bipolar Voltage-Controlled Oscillators Aleksandar Tasic the active part of the oscillator and the LC-tank, as proposed in this paper, the voltage swing over the tank of high- performance bipolar voltage-controlled oscillators (VCO's). As the voltage-controlled oscillators

  1. Neurocomputing 69 (2006) 10621065 Dependence of the spike-triggered average voltage on

    E-Print Network [OSTI]

    Gerstner, Wulfram

    2006-01-01T23:59:59.000Z

    .V. All rights reserved. Keywords: Spike-triggered voltage; h-current; Damped voltage oscillations 1 oscillations. The model comprises a variable v for the membrane voltage, with time-scale tv and a secondNeurocomputing 69 (2006) 1062­1065 Dependence of the spike-triggered average voltage on membrane

  2. Requirements for a Standard Test to Rate the Durability of PV Modules at System Voltage (Presentation)

    SciTech Connect (OSTI)

    Hacke, P.; Terwilliger, K.; Glick, S.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

    2011-02-01T23:59:59.000Z

    Degradation modes in photovoltaic modules under system bias voltage stress are described and classified.

  3. DATE04 SPECIAL SECTION Overhead-conscious voltage selection for dynamic

    E-Print Network [OSTI]

    Marchal, Loris

    combination with dynamic voltage scaling indispensable for energy-efficient designs in the foreseeable future

  4. Radio-Frequency Interference (RFI) From Extra-High-Voltage (EHV) Transmission Lines

    E-Print Network [OSTI]

    Ellingson, Steven W.

    -current (HVAC) transmission lines; high-voltage direct-current (HVDC) transmission lines will be addressed

  5. Voltage sensing in ion channels: Mesoscale simulations of biological devices

    E-Print Network [OSTI]

    Peyser, Alexander

    2012-01-01T23:59:59.000Z

    Electrical signaling via voltage-gated ion channels depends upon the function of a voltage sensor (VS), identified with the S1-S4 domain in voltage-gated K+ channels. Here we investigate some energetic aspects of the sliding-helix model of the VS using simulations based on VS charges, linear dielectrics and whole-body motion. Model electrostatics in voltage-clamped boundary conditions are solved using a boundary element method. The statistical mechanical consequences of the electrostatic configurational energy are computed to gain insight into the sliding-helix mechanism and to predict experimentally measured ensemble properties such as gating charge displaced by an applied voltage. Those consequences and ensemble properties are investigated for two alternate S4 configurations, \\alpha- and 3(10)-helical. Both forms of VS are found to have an inherent electrostatic stability. Maximal charge displacement is limited by geometry, specifically the range of movement where S4 charges and counter-charges overlap in t...

  6. High voltage stability performance of a gamma ray detection device

    SciTech Connect (OSTI)

    Abdullah, Nor Arymaswati; Lombigit, Lojius; Rahman, Nur Aira Abd [Technical Support Division, Malaysian Nuclear Agency, 43000 Kajang, Selangor (Malaysia)

    2014-02-12T23:59:59.000Z

    An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics.

  7. Voltage Impacts of Utility-Scale Distributed Wind

    SciTech Connect (OSTI)

    Allen, A.

    2014-09-01T23:59:59.000Z

    Although most utility-scale wind turbines in the United States are added at the transmission level in large wind power plants, distributed wind power offers an alternative that could increase the overall wind power penetration without the need for additional transmission. This report examines the distribution feeder-level voltage issues that can arise when adding utility-scale wind turbines to the distribution system. Four of the Pacific Northwest National Laboratory taxonomy feeders were examined in detail to study the voltage issues associated with adding wind turbines at different distances from the sub-station. General rules relating feeder resistance up to the point of turbine interconnection to the expected maximum voltage change levels were developed. Additional analysis examined line and transformer overvoltage conditions.

  8. Extinction Risk, Ecological Stress and Climate Change: How Species Respond to Changes in Global Biodiversity?

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    1 Extinction Risk, Ecological Stress and Climate Change: How Species Respond to Changes in Global subordinate species less intelligent than us, at risk of extinction. In other words, anthropogenic activities have made other species sensitive to changes in climate and habitat vulnerable to extinction [Parry et

  9. From Plants to Birds: Higher Avian Predation Rates in Trees Responding to Insect Herbivory

    E-Print Network [OSTI]

    Laaksonen, Toni

    From Plants to Birds: Higher Avian Predation Rates in Trees Responding to Insect Herbivory Elina Ma: An understanding of the evolution of potential signals from plants to the predators of their herbivores may provide the attraction of predators to plants is crucial to conclusions about co-evolution. For example, insectivorous

  10. Guide on Preventing and Responding to All Forms of Violence in the Workplace

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2014-10-21T23:59:59.000Z

    To ensure all sites have the tools to implement processes, we have created this guide. Each site is expected to develop its own site specific set of procedures/process to implement DOE Policy 444.1 Preventing and Responding to all forms of violence in the Workplace.

  11. Application of PLM processes to respond to mechanical SMEs needs. Julien Le Duigou1

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Application of PLM processes to respond to mechanical SMEs needs. Julien Le Duigou1 , Alain Bernard Jean-charles.delplace@cetim.fr Abstract PLM is today a reality for mechanical SMEs. Some companies implement PLM systems very well but others have more difficulties. This paper aims to explain why some SMEs

  12. Responding to environmental change: plastic responses1 vary little in a synchronous breeder.2

    E-Print Network [OSTI]

    Nussey, Dan

    The impact of environmental change on animal populations is strongly influenced by the10 ability. 2002).5 Determining how individuals base key life-history decisions on environmental cues is6 therefore1 Responding to environmental change: plastic responses1 vary little in a synchronous breeder.2 3

  13. A network that responds to water resource issues by advancing knowledge through

    E-Print Network [OSTI]

    Water Wells and Septic Systems · Animal Agriculture: Production and Manure Management The informationThe Land-Grant University System A network that responds to water resource issues by advancing knowledge through research, education and extension projects. Applying knowledge to improve water quality

  14. A study of temperature compensating circuits for voltage references which use negative temperature coefficient zener diodes

    E-Print Network [OSTI]

    Coleman, Spencer Delano

    1961-01-01T23:59:59.000Z

    Character- istics in Breakdown Region . 13 3f. 1N 751 Zener Diode Voltage vs Current Character- istics in Breakdown Region . 14 3g, lN752 Zener Diode Voltage vs Current Character- istics in Breakdown Region 15 4a. 1N746 Zener Diode Ambient Temperature... vs Voltage Characteristics in Breakdown Region. . . . . . . . . . 16 4b. IN747 Zener Diode Ambient Temperature vs Voltage Characteristics in Breakdown Region. . . . . . . . . . 17 4c. 1N748 Zener Diode Ambient Temperature vs Voltage...

  15. Chapter 24: Alternating-Current Circuits 2. The voltage in the European wall socket oscillates between the positive and negative peak voltages, resulting in an rms

    E-Print Network [OSTI]

    Kioussis, Nicholas

    1 Chapter 24: Alternating-Current Circuits 2. The voltage in the European wall socket oscillates 240 V 340 VV V 6. A light bulb dissipates power as the voltage oscillates across its filament.0 V 1.32 A 15.2 V I X 13. An oscillating voltage drives an alternating current through a capacitor

  16. Low-voltage ultra-low-poweranalog IC design -djmamic translinearcircuits 1.3.1 1.3 Low-voltage ultra-low-power analog IC design

    E-Print Network [OSTI]

    Serdijn, Wouter A.

    Low-voltage ultra-low-poweranalog IC design -djmamic translinearcircuits 1.3.1 1.3 Low-voltage ultra-low-power analog IC design -dynamic translinear circuits 0 (rg G x m .- E . . . . . a r, a" P, 44' s" +N m - _ c o3 #12;Low-voltage ultra-low-power analog IC design -dynamic translinear circuits I

  17. High voltage switch triggered by a laser-photocathode subsystem

    DOE Patents [OSTI]

    Chen, Ping; Lundquist, Martin L.; Yu, David U. L.

    2013-01-08T23:59:59.000Z

    A spark gap switch for controlling the output of a high voltage pulse from a high voltage source, for example, a capacitor bank or a pulse forming network, to an external load such as a high gradient electron gun, laser, pulsed power accelerator or wide band radar. The combination of a UV laser and a high vacuum quartz cell, in which a photocathode and an anode are installed, is utilized as triggering devices to switch the spark gap from a non-conducting state to a conducting state with low delay and low jitter.

  18. Effects of Distributed Energy Resources on Conservation Voltage Reduction (CVR)

    SciTech Connect (OSTI)

    Singh, Ruchi; Tuffner, Francis K.; Fuller, Jason C.; Schneider, Kevin P.

    2011-10-10T23:59:59.000Z

    Conservation Voltage Reduction (CVR) is one of the cheapest technologies which can be intelligently leveraged to provide considerable energy savings. The addition of renewables in the form of distributed resources can affect the entire power system, but more importantly, affects the traditional substation control schemes at the distribution level. This paper looks at the effect on energy consumption, peak load reduction, and voltage profile changes due to the addition of distributed generation in a distribution feeder using combinations of volt var control. An IEEE 13-node system is used to simulate the various cases. Energy savings and peak load reduction for different simulation scenarios are compared.

  19. UNIVERSITY STANDARDS AND REGULATIONS

    E-Print Network [OSTI]

    Royer, Dana

    2014­2015 UNIVERSITY STANDARDS AND REGULATIONS #12;Wesleyan University does not discriminate STANDARDS OF CONDUCT

  20. UNIVERSITY STANDARDS AND REGULATIONS

    E-Print Network [OSTI]

    Royer, Dana

    2013­2014 UNIVERSITY STANDARDS AND REGULATIONS #12;Wesleyan University does not discriminate STANDARDS OF CONDUCT

  1. A digital controlled solar array regulator employing the charge control

    SciTech Connect (OSTI)

    Cho, Y.J.; Cho, B.H. [Seoul National Univ. (Korea, Republic of)

    1997-12-31T23:59:59.000Z

    A microprocessor controlled SAR system is presented. The inner analog loops employing the charge current control scheme continuously regulate the solar array output power according to the reference value generated by the ECU. The ECU consists of the peak power tracking and the battery charge current regulation algorithm. Modeling, analysis and a design procedure of the inner loops and the system loop are presented taking into account of interaction between the inner analog loops and the outer digital loops. Utilizing the inherent characteristics of the inner voltage and current loop, the system dynamic performance and stability can be optimized up to the speed limit of the microprocessor.

  2. Way to reduce arc voltage losses in hybrid thermionic converters

    SciTech Connect (OSTI)

    Tskhakaya, V.K.; Yarygin, V.I.

    1982-03-01T23:59:59.000Z

    Experimental results are reported concerning the output and emission characteristics of the arc and hybrid regimes in a plane-parallel thermionic converter with Pt--Zr--O electrode pair. It is shown that arc voltage losses can be reduced to values below those obtainable in ordinary arc thermionic converters.

  3. Standby Voltage Scaling for Reduced Power B. Calhoun, A. Chandrakasan

    E-Print Network [OSTI]

    Calhoun, Benton H.

    Engineering Massachusetts Institute of Technology, Cambridge, MA Abstract Lowering VDD during standby mode leakage, gate leakage, GIDL, and forward biased diode leak- age[2]. At the 0.13 m technology node to pinch in the rail voltages during standby[5]. The quantity and sizes of the devices used in the diode

  4. Current isolating epitaxial buffer layers for high voltage photodiode array

    DOE Patents [OSTI]

    Morse, Jeffrey D. (Martinez, CA); Cooper, Gregory A. (Pleasant Hill, CA)

    2002-01-01T23:59:59.000Z

    An array of photodiodes in series on a common semi-insulating substrate has a non-conductive buffer layer between the photodiodes and the semi-insulating substrate. The buffer layer reduces current injection leakage between the photodiodes of the array and allows optical energy to be converted to high voltage electrical energy.

  5. THREE DIMENSIONAL VISUALIZATIONS FOR POWER SYSTEM CONTINGENCY ANALYSIS VOLTAGE DATA

    E-Print Network [OSTI]

    that the power systems are now often operated closer to their limits to maximum transmission system utilizationTHREE DIMENSIONAL VISUALIZATIONS FOR POWER SYSTEM CONTINGENCY ANALYSIS VOLTAGE DATA Y. Sun IEEE security assessment is critical for detecting underlying problems in a power system. More frequent CA

  6. Enhanced Archaerhodopsin Fluorescent Protein Voltage Yiyang Gong1,2*

    E-Print Network [OSTI]

    Ferrari, Silvia

    Enhanced Archaerhodopsin Fluorescent Protein Voltage Indicators Yiyang Gong1,2* , Jin Zhong Li1 by nearly three-fold in comparison to Arch-D95N. Citation: Gong Y, Li JZ, Schnitzer MJ (2013) Enhanced; Published June 19, 2013 Copyright: © 2013 Gong et al. This is an open-access article distributed under

  7. Topical Review Voltage Dependence of the Na/K Pump

    E-Print Network [OSTI]

    Gadsby, David

    Topical Review Voltage Dependence of the Na/K Pump R.F. Rakowski1 , D.C. Gadsby2 , P. De Weer3 1, Philadelphia, PA 19104, USA Received: 2 August 1996/Revised: 13 September 1996 Introduction Whether Na/K pump & Rakowski, 1988). While it follows from first principles that the rate of net forward Na/K pumping must

  8. Electrodic voltages accompanying stimulated bioremediation of a uraniumcontaminated aquifer

    E-Print Network [OSTI]

    Hubbard, Susan

    the accumulation of dissolved sulfide and the removal of uranium from groundwater. The anomalies persisted for 45. Within 10 days of the voltage decrease, uranium concentrations rebounded from 0.2 to 0.8 mM, a level of bioreduced contaminants, such as uranium. Citation: Williams, K. H., A. L. N'Guessan, J. Druhan, P. E. Long

  9. Voltage Sequence Control Based High-Current Rectifier System

    E-Print Network [OSTI]

    Paderborn, Universität

    of transformer. A passive filter is added at the primary side to achieve power factor improvement over the range of output voltage. This scheme is optimized to determine optimum turns ratio of the transformer and optimum not enforce unity power factor operation and guidelines provided by harmonic standards such as IEEE-519

  10. Ultra-compact Marx-type high-voltage generator

    DOE Patents [OSTI]

    Goerz, David A. (Brentwood, CA); Wilson, Michael J. (Modesto, CA)

    2000-01-01T23:59:59.000Z

    An ultra-compact Marx-type high-voltage generator includes individual high-performance components that are closely coupled and integrated into an extremely compact assembly. In one embodiment, a repetitively-switched, ultra-compact Marx generator includes low-profile, annular-shaped, high-voltage, ceramic capacitors with contoured edges and coplanar extended electrodes used for primary energy storage; low-profile, low-inductance, high-voltage, pressurized gas switches with compact gas envelopes suitably designed to be integrated with the annular capacitors; feed-forward, high-voltage, ceramic capacitors attached across successive switch-capacitor-switch stages to couple the necessary energy forward to sufficiently overvoltage the spark gap of the next in-line switch; optimally shaped electrodes and insulator surfaces to reduce electric field stresses in the weakest regions where dissimilar materials meet, and to spread the fields more evenly throughout the dielectric materials, allowing them to operate closer to their intrinsic breakdown levels; and uses manufacturing and assembly methods to integrate the capacitors and switches into stages that can be arranged into a low-profile Marx generator.

  11. Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids Mehdi@et.aau.dk Abstract-- The concept of microgrid hierarchical control is presented, recently. In this paper, a hierarchical scheme which includes primary and secondary control levels is proposed for islanded microgrids

  12. Energy Efficient Datapath Scheduling using Multiple Voltages and Dynamic Clocking

    E-Print Network [OSTI]

    Mohanty, Saraju P.

    consumption of a device has to be minimum to increase battery life, the energy-delay- product hasEnergy Efficient Datapath Scheduling using Multiple Voltages and Dynamic Clocking Saraju P. Mohanty clocking in a co-ordinated manner in order to reduce energy consumption of datapath circuits. In dynamic

  13. Smart Grid Voltage Sag Detection using Instantaneous Features Extraction

    E-Print Network [OSTI]

    Boyer, Edmond

    encountered power quality disturbances. Index Terms--Smart grid, voltage sag detection, power quality (PQ as the generation system is moved nearby the distribution level and this is achieved by using a set of micro grids grids are their availability, reliability, and profitability; in order to fulfill power demand according

  14. Energy Efficiency in Low Voltage Hall Thrusters Jerry L. Ross

    E-Print Network [OSTI]

    King, Lyon B.

    Energy Efficiency in Low Voltage Hall Thrusters Jerry L. Ross Lyon B. King Energy efficiency/s of xenon. Acceleration and current efficiencies were compared to thrust efficiency over a range of magnet coil current values of 0 A - 2.5 A. Acceleration efficiencies were obtained with a 4-grid Retarding

  15. Memory Power Management via Dynamic Voltage/Frequency Scaling

    E-Print Network [OSTI]

    McGaughey, Alan

    years. In the data center environment, thermal management and power budgeting have become significant transitions [10, 23], or scal- ing active server power proportionally to load [2]. In this paper, we focusMemory Power Management via Dynamic Voltage/Frequency Scaling Howard David, Chris Fallin§, Eugene

  16. Memory Power Management via Dynamic Voltage/Frequency Scaling

    E-Print Network [OSTI]

    Mutlu, Onur

    years. In the data center environment, thermal management and power budgeting have become significant sleep transitions [10, 23], or scal- ing active server power proportionally to load [2]. In this paperMemory Power Management via Dynamic Voltage/Frequency Scaling Howard David, Chris Fallin§, Eugene

  17. Contribution Allocation for Voltage Stability In Deregulated Power Systems

    E-Print Network [OSTI]

    Contribution Allocation for Voltage Stability In Deregulated Power Systems Garng M. Huang, Senior, stability margin I. INTRODUCTION The deregulated power system is based on transactions; each part Member, IEEE, Kun Men Abstract: With deregulation of power systems, it is of great importance to know who

  18. Field Optimization of Three Dimensional High Voltage C. Trinitis

    E-Print Network [OSTI]

    Stamatakis, Alexandros

    Field Optimization of Three Dimensional High Voltage Equipment C. Trinitis Lehrstuhl f The goal of finding an optimal electric field strength distribution for arbitrary three di­ mensional­ cal optimization algorithm. The package ob­ tained from these three components is then able

  19. High Voltage DC Transmission 1.0 Introduction

    E-Print Network [OSTI]

    McCalley, James D.

    1 High Voltage DC Transmission 1.0 Introduction HVDC has been applied in electric power systems for many years now. Figure 1 illustrates worldwide many of the HVDC applications [1]. Fig. 1 ABB provides a webpage which summarizes HVDC projects by type and capacity or by commissioning year [2]. Wikipedia [3

  20. High Voltage DC Transmission 2 1.0 Introduction

    E-Print Network [OSTI]

    McCalley, James D.

    1 High Voltage DC Transmission 2 1.0 Introduction Interconnecting HVDC within an AC system requires on use of switching devices collectively referred to in the HVDC community as valves. Valves may be non. Fig. 1 There have been three types of devices for implementing HVDC converter circuits: mercury

  1. Addition and subtraction of spin pumping voltages in magnetic hybrid structures

    SciTech Connect (OSTI)

    Azevedo, A., E-mail: aac@df.ufpe.br; Alves Santos, O.; Cunha, R. O.; Rezende, S. M. [Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Rodríguez-Suárez, R. [Facultad de Física, Pontificia Universidad Católica de Chile, Casilla 306, Santiago (Chile)

    2014-04-14T23:59:59.000Z

    We report an investigation of the spin pumping voltage generated in bilayers of ferromagnetic/normal metal in which the ferromagnetic layer is yttrium iron garnet or Permalloy and the normal-metal layer is Pt or Ta. We also investigated a special case in which the voltage is detected in single layer of Permalloy under ferromagnetic resonance condition. It is shown that the spin pumping voltage generated in metallic bilayers have contributions from both layers and the resulting voltage depends on the relative signs of charge currents generated by the inverse spin Hall effect. For instance, the spin pumping voltage generated in Ta has the same sign as the one generate in single layer of Permalloy, but contrary to the voltage generated in Pt. When the voltage is measured in shunted metallic bilayers, the resulting voltage can be a sum or a subtraction of the voltages generated in both layers.

  2. Air-flow regulation system for a coal gasifier

    DOE Patents [OSTI]

    Fasching, George E. (Morgantown, WV)

    1984-01-01T23:59:59.000Z

    An improved air-flow regulator for a fixed-bed coal gasifier is provided which allows close air-flow regulation from a compressor source even though the pressure variations are too rapid for a single primary control loop to respond. The improved system includes a primary controller to control a valve in the main (large) air supply line to regulate large slow changes in flow. A secondary controller is used to control a smaller, faster acting valve in a secondary (small) air supply line parallel to the main line valve to regulate rapid cyclic deviations in air flow. A low-pass filter with a time constant of from 20 to 50 seconds couples the output of the secondary controller to the input of the primary controller so that the primary controller only responds to slow changes in the air-flow rate, the faster, cyclic deviations in flow rate sensed and corrected by the secondary controller loop do not reach the primary controller due to the high frequency rejection provided by the filter. This control arrangement provides at least a factor of 5 improvement in air-flow regulation for a coal gasifier in which air is supplied by a reciprocating compressor through a surge tank.

  3. Frequency Regulation Basics and Trends

    SciTech Connect (OSTI)

    Kirby, BJ

    2005-05-06T23:59:59.000Z

    The electric power system must address two unique requirements: the need to maintain a near real-time balance between generation and load, and the need to adjust generation (or load) to manage power flows through individual transmission facilities. These requirements are not new: vertically integrated utilities have been meeting them for a century as a normal part of conducting business. With restructuring, however, the services needed to meet these requirements, now called ''ancillary services'', are being more clearly defined. Ancillary services are those functions performed by the equipment and people that generate, control, and transmit electricity in support of the basic services of generating capacity, energy supply, and power delivery. The Federal Energy Regulatory Commission (FERC) has defined such services as those ''necessary to support the transmission of electric power from seller to purchaser given the obligations of control areas and transmitting utilities within those control areas to maintain reliable operations of the interconnected transmission system''. This statement recognizes the importance of ancillary services for both bulk-power reliability and support of commercial transactions. Balancing generation and load instantaneously and continuously is difficult because loads and generators are constantly fluctuating. Minute-to-minute load variability results from the random turning on and off of millions of individual loads. Longer-term variability results from predictable factors such as the daily and seasonal load patterns as well as more random events like shifting weather patterns. Generators also introduce unexpected fluctuations because they do not follow their generation schedules exactly and they trip unexpectedly due to a range of equipment failures. The output from wind generators varies with the wind. Storage technologies should be ideal suppliers of several ancillary services, including regulation, contingency reserves (spinning reserve, supplemental reserve, replacement reserve), and voltage support. These services are not free; in regions with energy markets, generators are paid to supply these services. In vertically integrated utilities (without energy markets) the utility incurs significant costs to supply these services. Supplying these services may be a significant business opportunity for emerging storage technologies. This report briefly explores the various ancillary services that may be of interest to storage. It then focuses on regulation, the most expensive ancillary service. It also examines the impact that increasing amounts of wind generation may have on regulation requirements, decreasing conventional regulation supplies, and the implications for energy storage.

  4. Responding to complexity in socio-economic systems: How to build a smart and resilient society?

    E-Print Network [OSTI]

    Helbing, Dirk

    2015-01-01T23:59:59.000Z

    The world is changing at an ever-increasing pace. And it has changed in a much more fundamental way than one would think, primarily because it has become more connected and interdependent than in our entire history. Every new product, every new invention can be combined with those that existed before, thereby creating an explosion of complexity: structural complexity, dynamic complexity, functional complexity, and algorithmic complexity. How to respond to this challenge? And what are the costs?

  5. GaN/AlGaN heterojunction infrared detector responding in 814 and 2070 m ranges

    E-Print Network [OSTI]

    Perera, A. G. Unil

    GaN/AlGaN heterojunction infrared detector responding in 8­14 and 20­70 m ranges G. Ariyawansa, M October 2006 A GaN/AlGaN heterojunction interfacial work function internal photoemission infrared detector, the work demonstrates 54 m 5.5 THz operation of the detector based on 1s­2p± transition of Si donors in GaN

  6. Response of hard red winter wheat (Triticum aestivum L.) to nitrogen and growth regulants

    E-Print Network [OSTI]

    Mages, Kevin Lee

    1986-01-01T23:59:59.000Z

    vars may have responded negatively with respect to grain yield. Brown and Earley (1973) suggested examining growth regulators in different environments and with different cu lti- vars before suggesting general use of PGRs. Yields of the hybrid...RESPONSE OF HARO REO WINTER WHEAT (Triticum aestivum L. ) TO NITROGEN ANO GROWTH REGULANTS A Thesis by KEVIN LEE MAGES Submitted to the Graduate College of Texas AlLM University in partial fulfillment of the requirements for the degree...

  7. Natural Gas Regulations (Kentucky)

    Broader source: Energy.gov [DOE]

    Kentucky Administrative Regulation title 805 promulgates the rules and regulations pertaining to natural gas production in Kentucky. In addition to KAR title 405, chapter 30, which pertains to any...

  8. Computer Use Regulation Introduction

    E-Print Network [OSTI]

    Liu, Paul

    Computer Use Regulation #12;Introduction · The following training materials will reference the contents of the Computer Use Regulations, but should not serve as a substitute for reading the actual responsibilities NCSU employees have under the regulations. · North Carolina State University's computer networks

  9. Emotion Regulation CONCEPTUAL FOUNDATIONS

    E-Print Network [OSTI]

    Gross, James J.

    CHAPTER 1 Emotion Regulation CONCEPTUAL FOUNDATIONS JAMES J. GROSS ROSS A. THOMPSON Standing, paper or plastic are made. Quotidian acts of emotion regulation such as this constitute one important- changes that require us to regulate how emotions are experienced and expressed. But what do people do

  10. 3 Library Regulations Definitions

    E-Print Network [OSTI]

    Mottram, Nigel

    3 Library Regulations Definitions In Regulation 3: 'Library' means the University Library as defined in Regulation 3.1; 'Library staff' means the staff of the University Library; 'Librarian' means the University Librarian and Head of Information Resources Directorate or nominee; `Library Committee' means

  11. Interline photovoltaic (I-PV) power plants for voltage unbalance compensation

    E-Print Network [OSTI]

    Moawwad, Ahmed

    This paper proposes a stationary-frame control method for voltage unbalance compensation using Interline Photovoltaic (I-PV) power system. I-PV power systems are controlled to compensate voltage unbalance autonomously. The ...

  12. Novel techniques for fault location, voltage profile calculation and visualization of transients

    E-Print Network [OSTI]

    Evrenosoglu, Cansin Yaman

    2009-05-15T23:59:59.000Z

    techniques of voltage profiles along transmission lines. A simple yet effective approach to accurately and rapidly obtain the voltage profile along a transmission line during fault transients is presented. The objective of the presented method is to eliminate...

  13. A low-voltage zero-crossing-based delta-sigma analog-to-digital converter

    E-Print Network [OSTI]

    Guyton, Matthew C. (Matthew Christopher)

    2010-01-01T23:59:59.000Z

    A zero-crossing-based (ZCB) switched-capacitor technique is presented for operation under low power supply voltages without gate boosting. Voltage ramp generators maintain common-mode level at each integrator output. ...

  14. Dynamic photorefractivity guided by single-pulse voltage

    SciTech Connect (OSTI)

    Agashkov, A. V., E-mail: agashkov@inel.bas.net.by; Kovalev, A. A. [National Academy of Sciences of Belarus, Institute of Electronics (Belarus); Parka, J. [Military University of Technology, Institute of Applied Physics (Poland)

    2008-03-15T23:59:59.000Z

    The dynamic photorefractivity in a cell with photoconducting orienting layers, filled with a nematic liquid crystal (LC) 6CHBT and a mixture of anthraquinone dyes AD1 and AD2, has been investigated. The single-pulse mode, in which the polarity and amplitude of a dc electric field applied to an LC cell are switched for a fixed time interval, has been used. The scheme of dynamic self-diffraction of low-power laser beams was used in the experiment. The dependences of the width and intensity of diffraction pulses on the bias and switching voltages have been investigated. It is established that the width and intensity of the diffraction pulse arising after initial voltage recovery depends also on the switching pulse width. At the optimal width of the control pulse, the diffraction efficiency increases by two orders of magnitude.

  15. Analysis of Solar Cell Quality Using Voltage Metrics: Preprint

    SciTech Connect (OSTI)

    Toberer, E. S.; Tamboli, A. C.; Steiner, M.; Kurtz, S.

    2012-06-01T23:59:59.000Z

    The highest efficiency solar cells provide both excellent voltage and current. Of these, the open-circuit voltage (Voc) is more frequently viewed as an indicator of the material quality. However, since the Voc also depends on the band gap of the material, the difference between the band gap and the Voc is a better metric for comparing material quality of unlike materials. To take this one step further, since Voc also depends on the shape of the absorption edge, we propose to use the ultimate metric: the difference between the measured Voc and the Voc calculated from the external quantum efficiency using a detailed balance approach. This metric is less sensitive to changes in cell design and definition of band gap. The paper defines how to implement this metric and demonstrates how it can be useful in tracking improvements in Voc, especially as Voc approaches its theoretical maximum.

  16. Evaluation of Conservation Voltage Reduction (CVR) on a National Level

    SciTech Connect (OSTI)

    Schneider, Kevin P.; Fuller, Jason C.; Tuffner, Francis K.; Singh, Ruchi

    2010-09-29T23:59:59.000Z

    Conservation Voltage Reduction (CVR) is a reduction of energy consumption resulting from a reduction of feeder voltage. While there have been numerous CVR systems deployed in North America there has been little substantive analytic analysis of the effect; the majority of the published results are based on empirical field measurements. Since these results are based on empirical measurements it is difficult to extrapolate how this technology will behave on the various types of distribution feeders found throughout the nation. This report has utilized the Taxonomy of Prototypical feeder developed under the Modern Grid Initiative (MGI), now the Modern Grid Strategy (MGS), in order to estimate the benefits of CVR on multiple distribution feeder types. This information will then be used to determine an estimate of the national benefits of a wide scale deployment of CVR.

  17. Intrinsically Disordered Proteins: Regulation and Disease Regulation of IDPs

    E-Print Network [OSTI]

    Babu, M. Madan

    31st Jan 2011 Intrinsically Disordered Proteins: Regulation and Disease Regulation of IDPs M. Madan ...........................................................................................................................................................................1 2. The need for regulating IDPs.................................................................................................................................................1 3. General principles of IDP regulation

  18. Low Voltage Reversible Electrowetting Exploiting Lubricated Polymer Honeycomb Substrates

    E-Print Network [OSTI]

    Edward Bormashenko; Roman Pogreb; Yelena Bormashenko; Roman Grynyov; Oleg Gendelman

    2014-06-16T23:59:59.000Z

    Low-voltage electrowetting-on-dielectric scheme realized with lubricated honeycomb polymer surfaces is reported. Polycarbonate honeycomb reliefs manufactured with the breath-figures self-assembly were impregnated with silicone and castor oils. The onset of the reversible electrowetting for silicone oil impregnated substrates occurred at 35 V, whereas for castor oil impregnated ones it took place at 80 V. The semi-quantitative analysis of electrowetting of impregnated surfaces is proposed.

  19. Magnetic shielding of Hall thrusters at high discharge voltages

    SciTech Connect (OSTI)

    Mikellides, Ioannis G., E-mail: Ioannis.G.Mikellides@jpl.nasa.gov; Hofer, Richard R.; Katz, Ira; Goebel, Dan M. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109 (United States)

    2014-08-07T23:59:59.000Z

    A series of numerical simulations and experiments have been performed to assess the effectiveness of magnetic shielding in a Hall thruster operating in the discharge voltage range of 300–700?V (I{sub sp}???2000–2700?s) at 6?kW, and 800?V (I{sub sp} ? 3000) at 9?kW. At 6?kW, the magnetic field topology with which highly effective magnetic shielding was previously demonstrated at 300?V has been retained for all other discharge voltages; only the magnitude of the field has been changed to achieve optimum thruster performance. It is found that magnetic shielding remains highly effective for all discharge voltages studied. This is because the channel is long enough to allow hot electrons near the channel exit to cool significantly upon reaching the anode. Thus, despite the rise of the maximum electron temperature in the channel with discharge voltage, the electrons along the grazing lines of force remain cold enough to eliminate or reduce significantly parallel gradients of the plasma potential near the walls. Computed maximum erosion rates in the range of 300–700?V are found not to exceed 10{sup ?2}?mm/kh. Such rates are ?3 orders of magnitude less than those observed in the unshielded version of the same thruster at 300?V. At 9?kW and 800?V, saturation of the magnetic circuit did not allow for precisely the same magnetic shielding topology as that employed during the 6-kW operation since this thruster was not designed to operate at this condition. Consequently, the maximum erosion rate at the inner wall is found to be ?1 order of magnitude higher (?10{sup ?1}?mm/kh) than that at 6?kW. At the outer wall, the ion energy is found to be below the sputtering yield threshold so no measurable erosion is expected.

  20. Linear inductive voltage adders (IVA) for advanced hydrodynamic radiography

    SciTech Connect (OSTI)

    Mazarakis, M.G.; Boyes, J.D.; Johnson, D.L. [and others

    1998-09-01T23:59:59.000Z

    The electron beam which drifts through the multiple cavities of conventional induction linacs (LIA) is replaced in an IVA by a cylindrical metal conductor which extends along the entire length of the device and effectuates the addition of the accelerator cavity voltages. In the approach to radiography, the linear inductive voltage adder drives a magnetically immersed electron diode with a millimeter diameter cathode electrode and a planar anode/bremsstrahlung converter. Both anode and cathode electrodes are immersed in a strong (15--50 T) solenoidal magnetic field. The electron beam cross section is approximately of the same size as the cathode needle and generates a similar size, very intense x-ray beam when it strikes the anode converter. An IVA driven diode can produce electron beams of equal size and energy as a LIA but with much higher currents (40--50 kA versus 4--5 kA), simpler hardware and thus lower cost. The authors present here first experimental validations of the technology utilizing HERMES 3 and SABRE IVA accelerators. The electron beam voltage and current were respectively of the order of 10 MV and 40 kA. X-ray doses of up to 1 kR {at} 1 m and spot sizes as small as 1.7 mm (at 200 R doses) were measured.

  1. Fiber optic current monitor for high-voltage applications

    DOE Patents [OSTI]

    Renda, G.F.

    1992-04-21T23:59:59.000Z

    A current monitor which derives its power from the conductor being measured for bidirectionally measuring the magnitude of current (from DC to above 50 khz) flowing through a conductor across which a relatively high level DC voltage is applied, includes a pair of identical transmitter modules connected in opposite polarity to one another in series with the conductor being monitored, for producing from one module a first light signal having an intensity directly proportional to the magnitude of current flowing in one direction through the conductor during one period of time, and from the other module a second light signal having an intensity directly proportional to the magnitude of current flowing in the opposite direction through the conductor during another period of time, and a receiver located in a safe area remote from the high voltage area for receiving the first and second light signals, and converting the same to first and second voltage signals having levels indicative of the magnitude of current being measured at a given time. 6 figs.

  2. Advanced Gate Drive for the SNS High Voltage Converter Modulator

    SciTech Connect (OSTI)

    Nguyen, M.N.; Burkhart, C.; Kemp, M.A.; /SLAC; Anderson, D.E.; /Oak Ridge

    2009-05-07T23:59:59.000Z

    SLAC National Accelerator Laboratory is developing a next generation H-bridge switch plate [1], a critical component of the SNS High Voltage Converter Modulator [2]. As part of that effort, a new IGBT gate driver has been developed. The drivers are an integral part of the switch plate, which are essential to ensuring fault-tolerant, high-performance operation of the modulator. The redesigned driver improves upon the existing gate drive in several ways. The new gate driver has improved fault detection and suppression capabilities; suppression of shoot-through and over-voltage conditions, monitoring of dI/dt and Vce(sat) for fast over-current detection and suppression, and redundant power isolation are some of the added features. In addition, triggering insertion delay is reduced by a factor of four compared to the existing driver. This paper details the design and performance of the new IGBT gate driver. A simplified schematic and description of the construction are included. The operation of the fast over-current detection circuits, active IGBT over-voltage protection circuit, shoot-through prevention circuitry, and control power isolation breakdown detection circuit are discussed.

  3. Thermally-induced voltage alteration for integrated circuit analysis

    DOE Patents [OSTI]

    Cole, Jr., Edward I. (Albuquerque, NM)

    2000-01-01T23:59:59.000Z

    A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing an integrated circuit (IC) either from a device side of the IC or through the IC substrate to locate any open-circuit or short-circuit defects therein. The TIVA apparatus uses constant-current biasing of the IC while scanning a focused laser beam over electrical conductors (i.e. a patterned metallization) in the IC to produce localized heating of the conductors. This localized heating produces a thermoelectric potential due to the Seebeck effect in any conductors with open-circuit defects and a resistance change in any conductors with short-circuit defects, both of which alter the power demand by the IC and thereby change the voltage of a source or power supply providing the constant-current biasing. By measuring the change in the supply voltage and the position of the focused and scanned laser beam over time, any open-circuit or short-circuit defects in the IC can be located and imaged. The TIVA apparatus can be formed in part from a scanning optical microscope, and has applications for qualification testing or failure analysis of ICs.

  4. Thermally-induced voltage alteration for analysis of microelectromechanical devices

    DOE Patents [OSTI]

    Walraven, Jeremy A. (Albuquerque, NM); Cole, Jr., Edward I. (Albuquerque, NM)

    2002-01-01T23:59:59.000Z

    A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing a microelectromechanical (MEM) device with or without on-board integrated circuitry. One embodiment of the TIVA apparatus uses constant-current biasing of the MEM device while scanning a focused laser beam over electrically-active members therein to produce localized heating which alters the power demand of the MEM device and thereby changes the voltage of the constant-current source. This changing voltage of the constant-current source can be measured and used in combination with the position of the focused and scanned laser beam to generate an image of any short-circuit defects in the MEM device (e.g. due to stiction or fabrication defects). In another embodiment of the TIVA apparatus, an image can be generated directly from a thermoelectric potential produced by localized laser heating at the location of any short-circuit defects in the MEM device, without any need for supplying power to the MEM device. The TIVA apparatus can be formed, in part, from a scanning optical microscope, and has applications for qualification testing or failure analysis of MEM devices.

  5. Load regulating expansion fixture

    DOE Patents [OSTI]

    Wagner, Lawrence M. (San Jose, CA); Strum, Michael J. (San Jose, CA)

    1998-01-01T23:59:59.000Z

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components.

  6. Load regulating expansion fixture

    DOE Patents [OSTI]

    Wagner, L.M.; Strum, M.J.

    1998-12-15T23:59:59.000Z

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils is disclosed. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components. 1 fig.

  7. Voltage Stability and Power Quality Issues of Wind Farm with Series Compensation

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Voltage Stability and Power Quality Issues of Wind Farm with Series Compensation T. F. Orchi generator (DFIG) wind farms with series and shunt compensation are analyzed. The voltage source converter of the wind farm are modeled with flicker coefficients as defined by IEC standard 61400 and voltage sag

  8. Impact of Compiler Optimizations on Voltage Droops and Reliability of an SMT, Multi-Core Processor

    E-Print Network [OSTI]

    John, Lizy Kurian

    Impact of Compiler Optimizations on Voltage Droops and Reliability of an SMT, Multi-Core Processor unreliable operation in microprocessors. Voltage droops due to di/dt effects have been studied in the past, however no prior work studies the effect of compiler optimizations on voltage droops. Past work has

  9. Analysis of Instruction-level Vulnerability to Dynamic Voltage and Temperature Variations

    E-Print Network [OSTI]

    Gupta, Rajesh

    and supply voltage droops [2]. Static process variations can sometimes be mitigated through binning of dynamic variation from environmental and workload changes include supply voltage droops and temperature changes. Voltage droops result from abrupt changes in the switching activity, inducing large current

  10. October 6, 2006 V. Ghazikhanian 1 TOF Low Voltage System Review

    E-Print Network [OSTI]

    Llope, William J.

    TOF Low Voltage Power System. The TOF low voltage system is based on the Wiener PL512 low noise, high45 plugs #12;October 6, 2006 V. Ghazikhanian Tray Low Voltage Power System. Totalof120 the plot of the dark current data on slide]. The DC power will be transmitted via DC transmission lines

  11. An earth-isolated optically coupled wideband high voltage probe powered by ambient light

    E-Print Network [OSTI]

    Bellan, Paul M.

    An earth-isolated optically coupled wideband high voltage probe powered by ambient light Xiang Zhai) An earth-isolated optically coupled wideband high voltage probe powered by ambient light Xiang Zhaia online 9 October 2012) An earth-isolated optically-coupled wideband high voltage probe has been developed

  12. Parameter Variation Analysis for Voltage Controlled Oscillators in Phase-Locked Loops

    E-Print Network [OSTI]

    Moon, Un-Ku

    Parameter Variation Analysis for Voltage Controlled Oscillators in Phase-Locked Loops Igor Vytyaz), the oscillation frequency of a voltage-controlled oscillator (VCO) is specified by the reference frequency on the oscillation frequency as the PLL adjusts the control voltage to keep the frequency unchanged. More importantly

  13. 1. ABSTRACT A 1.4-GHz LC voltage-controlled oscillator has

    E-Print Network [OSTI]

    Lee, Thomas H.

    1. ABSTRACT A 1.4-GHz LC voltage-controlled oscillator has been implemented in a MOSIS 0.5-µm CMOS integrated, low noise, low power voltage-controlled oscillator (VCO). For higher quality receivers, an LC the overall phase noise. In this paper, we present such an LC voltage-controlled oscillator fabricated through

  14. EFFECTS OF SUBSTRATE ON PHASE-NOISE OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS

    E-Print Network [OSTI]

    Serdijn, Wouter A.

    EFFECTS OF SUBSTRATE ON PHASE-NOISE OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS Aleksandar Tasic predict a dramatically different performance of the oscillators, being different phase-noise, voltage of quasi-tapped bipolar voltage-controlled oscillators [2], phase- noise being of most interest. Contrary

  15. Fast Optimization of Nano-CMOS Voltage-Controlled Oscillator using Polynomial Regression and Genetic Algorithm

    E-Print Network [OSTI]

    Mohanty, Saraju P.

    Fast Optimization of Nano-CMOS Voltage-Controlled Oscillator using Polynomial Regression in a current-starved 50nm voltage-controlled oscillator (VCO). Accurate polynomial-regression based models have-CMOS), Voltage-Controlled Oscillator (VCO). 1. Introduction Digital design exploration and optimization is highly

  16. CONCEPT OF FREQUENCY-TRANSCONDUCTANCE TUNING OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS

    E-Print Network [OSTI]

    Serdijn, Wouter A.

    CONCEPT OF FREQUENCY-TRANSCONDUCTANCE TUNING OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS Aleksandar-transconductance tuning, introduced in this paper, offers the possibility for voltage-controlled oscillators to trade-tank, the loop-gain, the voltage swing and the phase-noise of the oscillator are changed as well

  17. Understanding Pound-Drever-Hall locking using voltage controlled radio-frequency oscillators: An undergraduate experiment

    E-Print Network [OSTI]

    Le Roy, Robert J.

    Understanding Pound-Drever-Hall locking using voltage controlled radio-frequency oscillators. The three main pieces of equipment are a commercial voltage controlled oscillator, a resonating cavity of the voltage controlled oscillator. The cavity resonance is then observed by scanning the frequency

  18. The vertical voltage termination technique characterizations of single die multiple 600V power

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    The vertical voltage termination technique ­ characterizations of single die multiple 600V power.grenoble-inp.fr Abstract-- Deep trench terminations are commonly known as a technique to achieve ideal breakdown voltages for high voltage devices. This paper presents the use of deep trench terminations as an original concept

  19. Measurement based Voltage Stability Monitoring of Power system Garng M. Huang

    E-Print Network [OSTI]

    Measurement based Voltage Stability Monitoring of Power system Garng M. Huang huang Station, TX 77843-3128 Abstract: Many papers discuss the voltage stability assessment of power system. The problem of voltage stability may be simply explained as inability of the power system to provide

  20. Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines: State-of-the-Art Review deals with low-voltage ride-through (LVRT) capability of wind turbines (WTs) and in particular those as to index some emerging solutions. Index Terms--Wind turbine, doubly-fed induction generator, low voltage

  1. Voltage-Sensitivity of Motoneuron NMDA Receptor Channels Is Modulated by Serotonin in the Neonatal Rat Spinal Cord

    E-Print Network [OSTI]

    Manitoba, University of

    isolated in tetrodotoxin, induces nonlinear membrane behavior that results in voltage oscillations which generate rhythmic voltage oscillations in the presence of NMDA and synaptic blockade (with tetrodotoxin application induces neither voltage oscillations (in synaptically isolated motoneurons) nor locomotor network

  2. Learning environment simulator: a tool for local decision makers and first responders

    SciTech Connect (OSTI)

    Leclaire, Rene J [Los Alamos National Laboratory; Hirsch, Gary B [CLE, INCORPORATED

    2009-01-01T23:59:59.000Z

    The National Infrastructure Simulation and Analysis Center (NISAC) has developed a prototype learning environment simulator (LES) based on the Critical Infrastructure Protection Decision Support System (CIPDSS) infrastructure and scenario models. The LES is designed to engage decision makers at the grass-roots level (local/city/state) to deepen their understanding of an evolving crisis, enhance their intuition and allow them to test their own strategies for events before they occur. An initial version is being developed, centered on a pandemic influenza outbreak and has been successfully tested with a group of hospital administrators and first responders. LES is not a predictive tool but rather a simulated environment allowing the user to experience the complexities of a crisis before it happens. Users can contrast various approaches to the crisis, competing with alternative strategies of their own or other participants. LES is designed to assist decision makers in making informed choices by functionally representing relevant scenarios before they occur, including impacts to critical infrastructures with their interdependencies, and estimating human health & safety and economic impacts. In this paper a brief overview of the underlying models are given followed by a description of the LES, its interface and usage and an overview of the experience testing LES with a group of hospital administrators and first responders. The paper concludes with a brief discussion of the work remaining to make LES operational.

  3. Respondent-driven sampling bias induced by clustering and community structure in social networks

    E-Print Network [OSTI]

    Rocha, Luis Enrique Correa; Lambiotte, Renaud; Liljeros, Fredrik

    2015-01-01T23:59:59.000Z

    Sampling hidden populations is particularly challenging using standard sampling methods mainly because of the lack of a sampling frame. Respondent-driven sampling (RDS) is an alternative methodology that exploits the social contacts between peers to reach and weight individuals in these hard-to-reach populations. It is a snowball sampling procedure where the weight of the respondents is adjusted for the likelihood of being sampled due to differences in the number of contacts. In RDS, the structure of the social contacts thus defines the sampling process and affects its coverage, for instance by constraining the sampling within a sub-region of the network. In this paper we study the bias induced by network structures such as social triangles, community structure, and heterogeneities in the number of contacts, in the recruitment trees and in the RDS estimator. We simulate different scenarios of network structures and response-rates to study the potential biases one may expect in real settings. We find that the ...

  4. Effect of energetic electrons on near-wall sheath voltage in the cathode region of a cold cathode direct current discharge

    SciTech Connect (OSTI)

    Blessington, J. [Department of Physics, West Virginia University, Morgantown, West Virginia 26506 (United States); Adams, S. F. [Air Force Research Laboratory, Wright-Patterson AFB, Ohio 45433 (United States); Demidov, V. I. [UES, Inc., 4401 Dayton-Xenia Road, Beavercreek, Ohio 45432 (United States); Department of Physics, West Virginia University, Morgantown, West Virginia 26506 (United States); Williamson, J. M. [Innovative Scientific Solutions, Inc., 2766 Indian Ripple Road, Ohio 45440-3638 (United States)

    2009-10-15T23:59:59.000Z

    It is experimentally demonstrated that energetic electrons originating from the cathode or produced in volumetric processes in the cathode region of a cold cathode direct current discharge can create a large potential drop in the near-wall sheath. This voltage drop may be much greater than kT{sub e}/e (where k is the Boltzmann constant, T{sub e} is the electron temperature, and e is the electron charge). Due to the large near-wall sheath voltage, slow and moderately energetic electrons cannot reach the wall and move toward the anode. Application of additional potentials to the wall can change the amount of energetic electrons reaching the wall. This effect can be used for regulation of the near-cathode plasma and near-wall sheath properties and thus may be useful in technical applications.

  5. A power regulator for the generators on the A.C. network calculator

    E-Print Network [OSTI]

    Francis, Lawrence Gregg

    1956-01-01T23:59:59.000Z

    Regulator 6. The Thermocouple Transducer 7. The Detector Testing Layout 8, The Thermocvuplc Detector 9? Effect of. Varying Paver when feeintaining Vacs 12 15 17 and Voltage Constant 1Q. D. C. Thermocouple Voltage Vs, Generator Pover Output 19 11... is that the sucrsstion of generator outputs equals or exceeds the load on the system. power may be shifted from one generator to the other according to the condition under study. Thus, by loading sll but one unit to the desired levels and letting the other unit seek...

  6. Miniaturized, low-voltage power converters with fast dynamic response

    E-Print Network [OSTI]

    Giuliano, David (David Michael)

    2013-01-01T23:59:59.000Z

    This thesis introduces a two-stage architecture that combines the strengths of switched capacitor (SC) techniques (small size, light-load performance) with the high efficiency and regulation capability of switch-mode power ...

  7. Results of a literature review on the environmental qualification of low-voltage electric cables

    SciTech Connect (OSTI)

    Lofaro, R.; Lee, B.; Villaran, M. [Brookhaven National Lab., Upton, NY (United States); Gleason, J. [GLS Enterprises, Inc. (United States); Aggarwal, S. [Nuclear Regulatory Commission, Washington, DC (United States)

    1995-12-31T23:59:59.000Z

    In the design of nuclear power plants in the US, safety-related electric equipment must be qualified to provide reasonable assurance it can withstand the effects of a design basis event (DBE) and still be able to perform its prescribed safety function, even if the accident were to occur at the end of its service life. The requirement for environmental qualification (EQ) originates from the General Design Criteria in the Code of Federal Regulations, Title 10, Part 50 (10 CFR 50). The acceptable method of performing the qualification of this equipment has evolved over the years, starting with the NRC Division of Operating Reactors (DOR) Guidelines, which were issued in Bulletin 79--01B, and NUREG-0588 requirements and ending with the current EQ Rule, 10 CFR 50.49. While the EQ methods described in these documents have the same overall objective, there are some notable differences for which a clear technical basis has not been established. One difference is the preaging requirement for equipment prior to LOCA testing. In addition, specific issues related to current EQ practices have been raised by the US NRC which need to be addressed. These issues, which are discussed in detail later in this paper, are related to the sources of conservatism and uncertainty in IEEE Standard 323--1974, which is the qualification standard currently endorsed by the NRC. To address these issues, the NRC Office of Nuclear Reactor Regulation (NRR) implemented a Task Action Plan (TAP), and the Office of Nuclear Reactor Research (RES) initiated a complementary research program. The current focus of this program is on the qualification of low-voltage instrumentation and control cables. These cables were selected since they are not typically replaced on a routine basis, and their degradation could impact plant safety.

  8. NEW - DOE G 444.1 1, Guide on Preventing and Responding to All Forms of Violence in the Workplace

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    This guide is a broad overview of the basic tools for a site to develop its site specific procedures for responding to workplace violence. Supports implementation of DOE P 444.1.

  9. Methods, systems and apparatus for controlling third harmonic voltage when operating a multi-space machine in an overmodulation region

    SciTech Connect (OSTI)

    Perisic, Milun; Kinoshita, Michael H; Ranson, Ray M; Gallegos-Lopez, Gabriel

    2014-06-03T23:59:59.000Z

    Methods, system and apparatus are provided for controlling third harmonic voltages when operating a multi-phase machine in an overmodulation region. The multi-phase machine can be, for example, a five-phase machine in a vector controlled motor drive system that includes a five-phase PWM controlled inverter module that drives the five-phase machine. Techniques for overmodulating a reference voltage vector are provided. For example, when the reference voltage vector is determined to be within the overmodulation region, an angle of the reference voltage vector can be modified to generate a reference voltage overmodulation control angle, and a magnitude of the reference voltage vector can be modified, based on the reference voltage overmodulation control angle, to generate a modified magnitude of the reference voltage vector. By modifying the reference voltage vector, voltage command signals that control a five-phase inverter module can be optimized to increase output voltages generated by the five-phase inverter module.

  10. Abstract--In this paper, we present the voltage build up process and the terminal voltage control of an isolated wind

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Abstract-- In this paper, we present the voltage build up process and the terminal voltage control that when capacitors are connected across the stator terminals of an induction machine, driven in the stator will continue to grow until steady-state condition is reached [2, 3]. However, self excitation has

  11. Coal Mining Regulations (Kentucky)

    Broader source: Energy.gov [DOE]

    Kentucky Administrative Regulation Title 405 chapters 1, 2, 3, 5, 7, 8, 10, 12, 16, 18 and 20 establish the laws governing coal mining in the state.

  12. Regulation of natural monopolies

    E-Print Network [OSTI]

    Joskow, Paul L.

    2005-01-01T23:59:59.000Z

    This chapter provides a comprehensive overview of the theoretical and empirical literature on the regulation of natural monopolies. It covers alternative definitions of natural monopoly, regulatory goals, alternative ...

  13. Regulations of Wells (Florida)

    Broader source: Energy.gov [DOE]

    The Department of Environmental Protection regulates the construction, repair, and abandonment of wells, as well as the persons and businesses undertaking such practices. Governing boards of water...

  14. Tidal Wetlands Regulations (Connecticut)

    Broader source: Energy.gov [DOE]

    Most activities occurring in or near tidal wetlands are regulated, and this section contains information on such activities and required permit applications for proposed activities. Applications...

  15. Utility Regulation (Indiana)

    Broader source: Energy.gov [DOE]

    The Indiana Utility Regulatory Commission enforces regulations in this legislation that apply to all individuals, corporations, companies, and partnerships that may own, operate, manage, or control...

  16. Induction of nuclear fission by high-voltage application

    E-Print Network [OSTI]

    Hirokazu Maruyama

    2007-11-20T23:59:59.000Z

    In nuclear power generation, fissile materials are mainly used. For example, $U^{235}$ is fissile and therefore quite essential for use of nuclear energy. However, the material $U^{235}$ has very small natural abundance less than 1 %. We should seek possibility of utilizing fissionable materials such as $U^{238}$ because natural abundance of such fissionable materials is generally much larger than fissile ones. In this paper, we show that thermal neutrons with vanishing kinetic energy can induce nuclear fission when high voltage is applied to fissionable materials. To obtain this result, we use the liquid-drop model for nuclei. Finally, we propose how fissionable materials can be utilized.

  17. Worldwide reliability surveys of high voltage circuit breakers

    SciTech Connect (OSTI)

    Heising, C.R.

    1995-05-01T23:59:59.000Z

    This article reports on the results of two CIGRE 13.06 Working Group worldwide surveys of the reliability of high voltage circuit breakers, 63 kV and above. The first inquiry included 78,000 breaker-years of ``in service data`` from 102 utilities in 22 countries during the years 1974--1977 and included all interrupting technologies. The second inquiry included 70,708 breaker-years from 132 utilities in 22 countries for the years 1988--1991 and only included single-pressure SF6 breakers, because this is what most utilities are now buying. Thirty-one US utilities submitted data.

  18. Light-weight DC to very high voltage DC converter

    DOE Patents [OSTI]

    Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

    1998-01-01T23:59:59.000Z

    A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

  19. Light-weight DC to very high voltage DC converter

    DOE Patents [OSTI]

    Druce, R.L.; Kirbie, H.C.; Newton, M.A.

    1998-06-30T23:59:59.000Z

    A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

  20. Outdoor PV Module Degradation of Current-Voltage Parameters: Preprint

    SciTech Connect (OSTI)

    Smith, R. M.; Jordan, D. C.; Kurtz, S. R.

    2012-04-01T23:59:59.000Z

    Photovoltaic (PV) module degradation rate analysis quantifies the loss of PV power output over time and is useful for estimating the impact of degradation on the cost of energy. An understanding of the degradation of all current-voltage (I-V) parameters helps to determine the cause of the degradation and also gives useful information for the design of the system. This study reports on data collected from 12 distinct mono- and poly-crystalline modules deployed at the National Renewable Energy Laboratory (NREL) in Golden, Colorado. Most modules investigated showed < 0.5%/year decrease in maximum power due to short-circuit current decline.

  1. Self-monitoring high voltage transmission line suspension insulator

    DOE Patents [OSTI]

    Stemler, Gary E. (Vancouver, WA); Scott, Donald N. (Vancouver, WA)

    1981-01-01T23:59:59.000Z

    A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

  2. Light-induced voltage alteration for integrated circuit analysis

    DOE Patents [OSTI]

    Cole, E.I. Jr.; Soden, J.M.

    1995-07-04T23:59:59.000Z

    An apparatus and method are described for analyzing an integrated circuit (IC). The invention uses a focused light beam that is scanned over a surface of the IC to generate a light-induced voltage alteration (LIVA) signal for analysis of the IC. The LIVA signal may be used to generate an image of the IC showing the location of any defects in the IC; and it may be further used to image and control the logic states of the IC. The invention has uses for IC failure analysis, for the development of ICs, for production-line inspection of ICs, and for qualification of ICs. 18 figs.

  3. Low Voltage Cables Market Analysis | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf KilaueaInformation Other4Q07) WindLow Voltage Cables Market Analysis

  4. Low Voltage Cables Market Trends | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf KilaueaInformation Other4Q07) WindLow Voltage Cables Market

  5. Low Voltage Cables Market size | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf KilaueaInformation Other4Q07) WindLow Voltage Cables MarketLow

  6. Low Voltage Cables Market | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf KilaueaInformation Other4Q07) WindLow Voltage Cables MarketLowLow

  7. HIGH-VOLTAGE SPINEL AND POLYANION CATHODES | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(Fact Sheet), GeothermalGrid Integration0-1HAWAI'I CLEANDepartmentDOEHIGH-VOLTAGE

  8. Consistent dynamics suggests tight regulation of biophysical parameters in a small network of bursting neurons.

    E-Print Network [OSTI]

    Szücs, Attila; Selverston, Allen I

    2006-01-01T23:59:59.000Z

    the emerging voltage oscillations and firing patterns. Ourresulted in smoother voltage oscillations in the neurons.induces irregular voltage oscillations. A shows the voltage

  9. REGULATION I: Responsibility for Creation and Amendment of Regulations

    E-Print Network [OSTI]

    REGULATION I: Responsibility for Creation and Amendment of Regulations 1. In accordance with Article 14 of the Charter, the Council shall have the power to make, amend or repeal Regulations. 2 of the Regulations and the delegation of such power pursuant to Regulation II (7.2) by the Council to Senate

  10. An accurate continuous calibration system for high voltage current transformer

    SciTech Connect (OSTI)

    Tong Yue; Li Binhong [College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, Hubei Province (China)

    2011-02-15T23:59:59.000Z

    A continuous calibration system for high voltage current transformers is presented in this paper. The sensor of this system is based on a kind of electronic instrument current transformer, which is a clamp-shape air core coil. This system uses an optical fiber transmission system for its signal transmission and power supply. Finally the digital integrator and fourth-order convolution window algorithm as error calculation methods are realized by the virtual instrument with a personal computer. It is found that this system can calibrate a high voltage current transformer while energized, which means avoiding a long calibrating period in the power system and the loss of power metering expense. At the same time, it has a wide dynamic range and frequency band, and it can achieve a high accuracy measurement in a complex electromagnetic field environment. The experimental results and the on-site operation results presented in the last part of the paper, prove that it can reach the 0.05 accuracy class and is easy to operate on site.

  11. Commercialization of Medium Voltage HTS Triax TM Cable Systems

    SciTech Connect (OSTI)

    Knoll, David

    2012-12-31T23:59:59.000Z

    The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

  12. Over Voltage in a Multi-sectioned Solenoid during a Quenching

    SciTech Connect (OSTI)

    Guo, Xinglong; Wang, Li; Pan, Heng; Wu, Hong; Liu, Xiaokun; Chen, Anbin; Green, M.A.; Xu, F.Y.

    2009-06-21T23:59:59.000Z

    Accurate analysis of over voltage in the superconducting solenoid during a quench is one of the bases for quench protection system design. Classical quench simulation methods can only give rough estimation of the over voltage within a magnet coil. In this paper, for multi-sectioned superconducting solenoid, based on the classical assumption of ellipsoidal normal zone, three-dimension al temperature results are mapped to the one-dimension of the wire, the temperature distribution along the wire and the resistances of each turn are obtained. The coil is treated as circuit comprised of turn resistances, turn self and mutual inductances. The turn resistive voltage, turn inductive voltage, and turn resultant voltage along the wire are calculated. As a result, maximum internal voltages, the layer-to-layer voltages and the turn-to-turn voltages are better estimated. Utilizing this method, the over voltage of a small solenoid and a large solenoid during quenching have been studied. The result shows that this method can well improve the over voltage estimate, especially when the coil is larger.

  13. Workshop in Regulation &

    E-Print Network [OSTI]

    Lin, Xiaodong

    Smart Grid and Regulatory Issues April 1, 2011 K&L Gates LLP, 1601 K Street, NW, Washington, DC Viable Regulation." Victor Glass, NECA, Comments January 14, 2011 Smart Grid and Regulatory Issues Location: Rutgers, The Brattle Group, "Smart Grid/Smart Regulation" John Caldwell, EEI, "Economic Efficiency and the Smart Grid

  14. DECENTRALIZED CONTROL ARCHITECTURE FOR COUPLING MICROGRIDS INTO DISTRIBUTION NETWORKS 1 Task 1: Coupling Low-Voltage Microgrids into

    E-Print Network [OSTI]

    Lemmon, Michael

    DECENTRALIZED CONTROL ARCHITECTURE FOR COUPLING MICROGRIDS INTO DISTRIBUTION NETWORKS 1 Task 1: Coupling Low-Voltage Microgrids into Mid-Voltage Distribution Systems Zhao Wang, Student Member, IEEE-voltage (LV) microgrids. At the same time, reactive power is dispatched coordinatively so that voltage

  15. Post-translational regulation enables robust p53 regulation

    E-Print Network [OSTI]

    Shin, Yong-Jun; Chen, Kai-Yuan; Sayed, Ali H; Hencey, Brandon; Shen, Xiling

    2013-01-01T23:59:59.000Z

    PS, Elowitz MB: Gene regulation at the single-cell level.JC, Song B, Kudo K, Chu E: Regulation of p53 expression inChen L, Li Z, et al: Regulation of MDM2 E3 ligase activity

  16. Pulsed voltage electrospray ion source and method for preventing analyte electrolysis

    DOE Patents [OSTI]

    Kertesz, Vilmos (Knoxville, TN); Van Berkel, Gary (Clinton, TN)

    2011-12-27T23:59:59.000Z

    An electrospray ion source and method of operation includes the application of pulsed voltage to prevent electrolysis of analytes with a low electrochemical potential. The electrospray ion source can include an emitter, a counter electrode, and a power supply. The emitter can include a liquid conduit, a primary working electrode having a liquid contacting surface, and a spray tip, where the liquid conduit and the working electrode are in liquid communication. The counter electrode can be proximate to, but separated from, the spray tip. The power system can supply voltage to the working electrode in the form of a pulse wave, where the pulse wave oscillates between at least an energized voltage and a relaxation voltage. The relaxation duration of the relaxation voltage can range from 1 millisecond to 35 milliseconds. The pulse duration of the energized voltage can be less than 1 millisecond and the frequency of the pulse wave can range from 30 to 800 Hz.

  17. Bright and fast voltage reporters across the visible spectrum via electrochromic FRET (eFRET)

    E-Print Network [OSTI]

    Zou, Peng; Douglass, Adam D; Hochbaum, Daniel R; Brinks, Daan; Werley, Christopher A; Harrison, D Jed; Campbell, Robert E; Cohen, Adam E

    2014-01-01T23:59:59.000Z

    We present a palette of brightly fluorescent genetically encoded voltage indicators (GEVIs) with excitation and emission peaks spanning the visible spectrum, sensitivities from 6 - 10% Delta F/F per 100 mV, and half-maximal response times from 1 - 7 ms. A fluorescent protein is fused to an Archaerhodopsin-derived voltage sensor. Voltage-induced shifts in the absorption spectrum of the rhodopsin lead to voltage-dependent nonradiative quenching of the appended fluorescent protein. Through a library screen, we identified linkers and fluorescent protein combinations which reported neuronal action potentials in cultured rat hippocampal neurons with a single-trial signal-to-noise ratio from 6.6 to 11.6 in a 1 kHz imaging bandwidth at modest illumination intensity. The freedom to choose a voltage indicator from an array of colors facilitates multicolor voltage imaging, as well as combination with other optical reporters and optogenetic actuators.

  18. Long term voltage stability analysis for small disturbances

    E-Print Network [OSTI]

    Men, Kun

    2009-05-15T23:59:59.000Z

    that there are three basic patterns: #0;? CBA PPP PPP? , both )Re(EigC and )Re(EigT are positive; when ),( CB PPP? , only )Re(EigT is positive. #0;? BCA PPP PPP? , both )Re(EigC and )Re(EigT are positive; when ),( BC PPP...? , only )Re(EigC is positive. #0;? Bifurcation point A disappears and CB PP PPP? . 3.2.2 PI- regulator Here the parameters of PI-regulator is given as 20or 0.5,5.2 === IIP TTK . Using equations (2...

  19. Understanding and Improving High Voltage Vacuum Insulators for Microsecond Pulses

    SciTech Connect (OSTI)

    Javedani, J B; Goerz, D A; Houck, T L; Lauer, E J; Speer, R D; Tully, L K; Vogtlin, G E; White, A D

    2007-03-05T23:59:59.000Z

    High voltage insulation is one of the main areas of pulsed power research and development, and dielectric breakdown is usually the limiting factor in attaining the highest possible performance in pulsed power devices. For many applications the delivery of pulsed power into a vacuum region is the most critical aspect of operation. The surface of an insulator exposed to vacuum can fail electrically at an applied field more than an order or magnitude below the bulk dielectric strength of the insulator. This mode of breakdown, called surface flashover, imposes serious limitations on the power flow into a vacuum region. This is especially troublesome for applications where high voltage conditioning of the insulator and electrodes is not practical and for applications where relatively long pulses, on the order of several microseconds, are required. The goal of this project is to establish a sound fundamental understanding of the mechanisms that lead to surface flashover, and then evaluate the most promising techniques to improve vacuum insulators and enable high voltage operation at stress levels near the intrinsic bulk breakdown limits of the material. The approach we proposed and followed was to develop this understanding through a combination of theoretical and computation methods coupled with experiments to validate and quantify expected behaviors. In this report we summarize our modeling and simulation efforts, theoretical studies, and experimental investigations. The computational work began by exploring the limits of commercially available codes and demonstrating methods to examine field enhancements and defect mechanisms at microscopic levels. Plasma simulations with particle codes used in conjunction with circuit models of the experimental apparatus enabled comparisons with experimental measurements. The large scale plasma (LSP) particle-in-cell (PIC) code was run on multiprocessor platforms and used to simulate expanding plasma conditions in vacuum gap regions. Algorithms were incorporated into LSP to handle secondary electron emission from dielectric materials to enable detailed simulations of flashover phenomenon. Theoretical studies were focused on explaining a possible mechanism for anode initiated surface flashover that involves an electron avalanche process starting near the anode, not a mechanism involving bulk dielectric breakdown. Experiments were performed in Engineering's Pulsed Power Lab using an available 100-kV, 10-{micro}s pulse generator and vacuum chamber. The initial experiments were done with polyethylene insulator material in the shape of a truncated cone cut at +45{sup o} angle between flat electrodes with a gap of 1.0 cm. The insulator was sized so there were no flashovers or breakdowns under nominal operating conditions. Insulator flashover or gap closure was induced by introducing a plasma source, a tuft of velvet, in proximity to the insulator or electrode.

  20. Systems and methods for process and user driven dynamic voltage and frequency scaling

    DOE Patents [OSTI]

    Mallik, Arindam (Evanston, IL); Lin, Bin (Hillsboro, OR); Memik, Gokhan (Evanston, IL); Dinda, Peter (Evanston, IL); Dick, Robert (Evanston, IL)

    2011-03-22T23:59:59.000Z

    Certain embodiments of the present invention provide a method for power management including determining at least one of an operating frequency and an operating voltage for a processor and configuring the processor based on the determined at least one of the operating frequency and the operating voltage. The operating frequency is determined based at least in part on direct user input. The operating voltage is determined based at least in part on an individual profile for processor.

  1. DOE Partnerships with States, Tribes and Other Federal Programs Help Responders Prepare for Challenges Involving Transport of Radioactive Materials

    SciTech Connect (OSTI)

    Marsha Keister

    2001-02-01T23:59:59.000Z

    DOE Partnerships with States, Tribes and Other Federal Programs Help Responders Prepare for Challenges Involving Transport of Radioactive Materials Implementing adequate institutional programs and validating preparedness for emergency response to radiological transportation incidents along or near U.S. Department of Energy (DOE) shipping corridors poses unique challenges to transportation operations management. Delayed or insufficient attention to State and Tribal preparedness needs may significantly impact the transportation operations schedule and budget. The DOE Transportation Emergency Preparedness Program (TEPP) has successfully used a cooperative planning process to develop strong partnerships with States, Tribes, Federal agencies and other national programs to support responder preparedness across the United States. DOE TEPP has found that building solid partnerships with key emergency response agencies ensures responders have access to the planning, training, technical expertise and assistance necessary to safely, efficiently and effectively respond to a radiological transportation accident. Through the efforts of TEPP over the past fifteen years, partnerships have resulted in States and Tribal Nations either using significant portions of the TEPP planning resources in their programs and/or adopting the Modular Emergency Response Radiological Transportation Training (MERRTT) program into their hazardous material training curriculums to prepare their fire departments, law enforcement, hazardous materials response teams, emergency management officials, public information officers and emergency medical technicians for responding to transportation incidents involving radioactive materials. In addition, through strong partnerships with Federal Agencies and other national programs TEPP provided technical expertise to support a variety of radiological response initiatives and assisted several programs with integration of the nationally recognized MERRTT program into other training venues, thus ensuring consistency of radiological response curriculums delivered to responders. This presentation will provide an overview of the steps to achieve coordination, to avoid redundancy, and to highlight several of the successful partnerships TEPP has formed with States, Tribes, Federal agencies and other national programs. Events, accident scenarios, and training where TEPP was proven to be integral in building the radiological response capabilities for first responders to actual radiological incidents are also highlighted. Participants will gain an appreciation for the collaborative efforts States and Tribes are engaging in with the DOE to ensure that responders all along the DOE transportation corridors are adequately prepared to respond to shipments of radioactive materials through their communities.

  2. Army Regulation 690600 Civilian Personnel

    E-Print Network [OSTI]

    US Army Corps of Engineers

    Army Regulation 690­600 Civilian Personnel Equal Employment Opportunity Discrimination Complaints Civilian Personnel Equal Employment Opportunity Discrimination Complaints *Army Regulation 690­600 Effective 9 March 2004 History. This publication is a major revision. Summary. This regulation establishes

  3. California Energy Commission PROPOSED REGULATIONS

    E-Print Network [OSTI]

    California Energy Commission PROPOSED REGULATIONS ENFORCEMENT PROCEDURES on concepts for the proposed regulations. Energy Commission staff held additional public workshops on March regulations. Throughout this process, the Energy Commission received and considered comments from

  4. California Energy Commission PROPOSED REGULATIONS

    E-Print Network [OSTI]

    California Energy Commission PROPOSED REGULATIONS MARCH 2012 CEC-400-2010-004-SD3 NONRESIDENTIAL BUILDING ENERGY USE DISCLOSURE PROGRAM Proposed Regulations Title 20, Division 2, Chapter 4 PREFACE The California Energy Commission is releasing proposed regulations for implementing Assembly

  5. High-speed, sub-pull-in voltage MEMS switching.

    SciTech Connect (OSTI)

    Spahn, Olga Blum; Brewer, Steven; Olsson, Roy H.; Bogart, Gregory R.; Luck, David L.; Watts, Michael R.; Shaw, Michael J.; Nielson, Gregory N.; Resnick, Paul James; Tigges, Christopher P.; Grossetete, Grant David

    2008-01-01T23:59:59.000Z

    We have proposed and demonstrated MEMS switching devices that take advantage of the dynamic behavior of the MEMS devices to provide lower voltage actuation and higher switching speeds. We have explored the theory behind these switching techniques and have demonstrated these techniques in a range of devices including MEMS micromirror devices and in-plane parallel plate MEMS switches. In both devices we have demonstrated switching speeds under one microsecond which has essentially been a firm limit in MEMS switching. We also developed low-loss silicon waveguide technology and the ability to incorporate high-permittivity dielectric materials with MEMS. The successful development of these technologies have generated a number of new projects and have increased both the MEMS switching and optics capabilities of Sandia National Laboratories.

  6. (Insulating materials and large high voltage electric systems)

    SciTech Connect (OSTI)

    Dale, S.J.

    1990-09-18T23:59:59.000Z

    The traveler attended the 33rd Session of CIGRE (The International Conference on Large High Voltage Electric Systems in Paris, France) as a US technical expert advisor the Study Committee 15, Insulating Materials. Over 200 papers were discussed, contributed from over 45 countries at the conference on all aspects of electric power generation and transmission. Of special interest was a panel session on superconducting technology for electric power systems and the participation on a new task force on the electrical insulation at cryogenic temperatures. Significant insight was gained into the development of superconducting power technologies in Europe and Japan. CIGRE has set up a committee to follow the development in research on the biological effects of electric and magnetic fields. The traveler also visited the Centre for Electric Power Engineering at the University of Strathclyde, Glasgow, Scotland and discussed research on degradation of polymeric cable insulation and gas insulated equipment. 5 refs.

  7. Effect of high-voltage nanosecond pulses on complex plasmas

    SciTech Connect (OSTI)

    Pustylnik, M. Y.; Ivlev, A. V.; Thomas, H. M.; Morfill, G. E. [Max-Planck-Institut fuer Extraterrestrische Physik, Giessenbachstrasse, 85741 Garching (Germany); Vasilyak, L. M.; Vetchinin, S. P.; Polyakov, D. N.; Fortov, V. E. [Joint Institute for High Temperatures, Russian Academy of Sciences, Izhorskaya 13/19, 125412 Moscow (Russian Federation)

    2009-11-15T23:59:59.000Z

    Influence of high-voltage (1-11 kV) pulses of nanosecond (20 ns) duration on microparticles levitating in a rf plasma is studied. It is shown that the pulses produce significant influence on the plasma, causing perturbations with the relaxation time of the order of 10{sup -4} s. This time is sufficient for the microparticle to acquire significant kinetic energy. Application of repetitive pulses leads to the vertical oscillations of the microparticles. Clusters, consisting of small number of microparticles, exhibit parametric instabilities of horizontal modes under the effect of repetitive pulses. It was shown that the parametric instability is caused by the vertical oscillations of the microparticles in the nonuniform environment of the sheath.

  8. High-voltage atmospheric breakdown across intervening rutile dielectrics.

    SciTech Connect (OSTI)

    Williamson, Kenneth Martin; Simpson, Sean; Coats, Rebecca Sue; Jorgenson, Roy Eberhardt; Hjalmarson, Harold Paul; Pasik, Michael Francis

    2013-09-01T23:59:59.000Z

    This report documents work conducted in FY13 on electrical discharge experiments performed to develop predictive computational models of the fundamental processes of surface breakdown in the vicinity of high-permittivity material interfaces. Further, experiments were conducted to determine if free carrier electrons could be excited into the conduction band thus lowering the effective breakdown voltage when UV photons (4.66 eV) from a high energy pulsed laser were incident on the rutile sample. This report documents the numerical approach, the experimental setup, and summarizes the data and simulations. Lastly, it describes the path forward and challenges that must be overcome in order to improve future experiments for characterizing the breakdown behavior for rutile.

  9. Nanowire-based ternary transistor by threshold-voltage manipulation

    SciTech Connect (OSTI)

    Han, Junebeom; Lim, Taekyung; Bong, Jihye; Seo, Keumyoung; Ju, Sanghyun, E-mail: shju@kgu.ac.kr [Department of Physics, Kyonggi University, Suwon, Gyeonggi-Do 443-760 (Korea, Republic of); Kim, Sunkook [Department of Electronics and Radio Engineering, Kyung Hee University, Yongin, Gyeonggi-Do 446-701 (Korea, Republic of)

    2014-04-07T23:59:59.000Z

    We report on a ternary device consisting of two nanowire channels that have different threshold voltage (V{sub th}) values and show that three current stages can be produced. A microscale laser-beam shot was utilized to selectively anneal the nanowire channel area to be processed, and the amount of V{sub th} shift could be controlled by adjusting the laser wavelength. Microscale laser annealing process could control V{sub th} of the individual nanowire transistors while maintaining the other parameters the constant, such as the subthreshold slope, on–off current ratio, and mobility. This result could provide a potential for highly integrated and high-speed ternary circuits.

  10. Probabilistic Vulnerability Assessment Based on Power Flow and Voltage Distribution

    SciTech Connect (OSTI)

    Ma, Jian; Huang, Zhenyu; Wong, Pak C.; Ferryman, Thomas A.

    2010-04-30T23:59:59.000Z

    Risk assessment of large scale power systems has been an important problem in power system reliability study. Probabilistic technique provides a powerful tool to solve the task. In this paper, we present the results of a study on probabilistic vulnerability assessment on WECC system. Cumulant based expansion method is applied to obtain the probabilistic distribution function (PDF) and cumulative distribution function (CDF) of power flows on transmission lines and voltage. Overall risk index based on the system vulnerability analysis is calculated using the WECC system. The simulation results based on WECC system is used to demonstrate the effectiveness of the method. The methodology can be applied to the risk analysis on large scale power systems.

  11. High voltage design structure for high temperature superconducting device

    DOE Patents [OSTI]

    Tekletsadik, Kasegn D. (Rexford, NY)

    2008-05-20T23:59:59.000Z

    In accordance with the present invention, modular corona shields are employed in a HTS device to reduce the electric field surrounding the HTS device. In a exemplary embodiment a fault current limiter module in the insulation region of a cryogenic cooling system has at least one fault current limiter set which employs a first corona shield disposed along the top portion of the fault current limiter set and is electrically coupled to the fault current limiter set. A second corona shield is disposed along the bottom portion of the fault current limiter set and is electrically coupled to the fault current limiter set. An insulation barrier is disposed within the insulation region along at least one side of the fault current limiter set. The first corona shield and the second corona shield act together to reduce the electric field surrounding the fault limiter set when voltage is applied to the fault limiter set.

  12. System and method for floating-substrate passive voltage contrast

    DOE Patents [OSTI]

    Jenkins, Mark W. (Albuquerque, NM); Cole, Jr., Edward I. (Albuquerque, NM); Tangyunyong, Paiboon (Albuquerque, NM); Soden, Jerry M. (Placitas, NM); Walraven, Jeremy A. (Albuquerque, NM); Pimentel, Alejandro A. (Albuquerque, NM)

    2009-04-28T23:59:59.000Z

    A passive voltage contrast (PVC) system and method are disclosed for analyzing ICs to locate defects and failure mechanisms. During analysis a device side of a semiconductor die containing the IC is maintained in an electrically-floating condition without any ground electrical connection while a charged particle beam is scanned over the device side. Secondary particle emission from the device side of the IC is detected to form an image of device features, including electrical vias connected to transistor gates or to other structures in the IC. A difference in image contrast allows the defects or failure mechanisms be pinpointed. Varying the scan rate can, in some instances, produce an image reversal to facilitate precisely locating the defects or failure mechanisms in the IC. The system and method are useful for failure analysis of ICs formed on substrates (e.g. bulk semiconductor substrates and SOI substrates) and other types of structures.

  13. Summary of multiterminal high-voltage direct current transmission technology

    SciTech Connect (OSTI)

    Biggs, R.B.; Jewell, W.T.

    1984-05-01T23:59:59.000Z

    This report summarizes the present state of multiterminal (MT) high-voltage direct current (HVDC) power transmission. The purpose is to reassess the need for HVDC circuit breakers and to identify needed research for MT HVDC. The fundamentals of this technology are presented, and previous research and development is reviewed. Although no MT HVDC systems have yet been built, many concepts have been proposed. Some require a dc breaker, and others do not. Both options have advantages and disadvantages for various applications, so the selection will depend on the proposed application. Research is needed to define operating characteristics of various MT HVDC systems. In some applications, dc breakers will be useful, so research into HVDC interruption should continue. Also, dc fault detection and control algorithms for MT systems should be studied.

  14. This paper presents a floating slider mechanism to achieve large scanning angular displacements with low voltage

    E-Print Network [OSTI]

    's natural frequency. After a 49% hydrofluoric acid and carbon dioxide LOW -VOLTAGE LARGE ANGULAR: Dual bimorph electrostatic actuator with floating sliders. #12;super-critical point release

  15. Hierarchical Control Scheme for Voltage Harmonics Compensation in an Islanded Droop-

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    Hierarchical Control Scheme for Voltage Harmonics Compensation in an Islanded Droop- Controlled on the resistance emulation. Furthermore, a droop characteristic based on DG harmonic reactive power has been

  16. Clustering-Based Simultaneous Task and Voltage Scheduling for NoC Systems

    E-Print Network [OSTI]

    Yang, Yu

    2011-08-08T23:59:59.000Z

    -means clustering. (a) cluster assignment. (b) center point moves to the mean of all elements in the cluster. : : : : : : : : : : : 16 4 One iteration in TILE clustering. There are four tiles T1,T2,T3 and T4. Two supply voltages are available. (a) TILE voltage... assignment at the beginning of iteration. (b) T4?s distances to the two voltages are re-evaluated. (c) T4 is assigned to a new voltage according to the re-evaluated distances. : : : : : : : : : : : : : : : : : : : : : : : : : : : 17 5 Comparison...

  17. activated si-gaas high-voltage: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Summary: ??This thesis is concerned with developing a new approach to high voltage transformers condition monitoring, which involve partial discharge (PD) measurement and...

  18. A new technique to reject dc-link voltage ripple in PWM inverters

    E-Print Network [OSTI]

    Shireen, Wajiha

    1990-01-01T23:59:59.000Z

    to acknowledge the support of my husband and parents. TA. BLE OF CONTENTS CHAPTER I INTRODUCTION Page I. l Inverter Power Supplies 1. 2 Output Voltage Control 1. 2. 1 Control Of Voltage Supplied To The Inverter I. 2. 2 Control Of Voltage Within... and output of Stage 3 78 34 Exact solution of the switching angle trajectories for harmonic elimination with voltage control (M). 85 CHAPTER I INTRODUCTION Finding ways to control the flow of electricity has been a. goal of inventors and scientists...

  19. Utility downsizings pose a dilemma for regulators

    SciTech Connect (OSTI)

    Cross, P.S.

    1993-08-01T23:59:59.000Z

    A utility's job-generating potential is critical to most local economies. At the same time, however, high utility employment levels maintain an upward pressure on rates, an effect that does not escape regulators' notice, especially during an economic slowdown. More than on regulator has been heard to say that hard-hit ratepayers should not be called on to support what some may seen as a bloated utility workforce scaled to better times. To complicate things even more, popular cost-cutting goals that include improving productivity and relying more on conservation could mean fewer jobs, at least at the utility. What's more, utility rates play a significant role in how local industries and businesses respond to an economic slowdown. This interplay of economic forces has complicated the ratemaking process. The size of a utility's workforce is an issue of growing significance in rate hearings. Forecasts for test-period salary and wage expenses are less reliable. Early retirement plans promise future savings for ratepayers, but at a cost today.

  20. Mobile biometric device (MBD) technology : summary of selected first responder experiences in pilot projects.

    SciTech Connect (OSTI)

    Aldridge, Chris D.

    2013-06-01T23:59:59.000Z

    Mobile biometric devices (MBDs) capable of both enrolling individuals in databases and performing identification checks of subjects in the field are seen as an important capability for military, law enforcement, and homeland security operations. The technology is advancing rapidly. The Department of Homeland Security Science and Technology Directorate through an Interagency Agreement with Sandia sponsored a series of pilot projects to obtain information for the first responder law enforcement community on further identification of requirements for mobile biometric device technology. Working with 62 different jurisdictions, including components of the Department of Homeland Security, Sandia delivered a series of reports on user operation of state-of-the-art mobile biometric devices. These reports included feedback information on MBD usage in both operational and exercise scenarios. The findings and conclusions of the project address both the limitations and possibilities of MBD technology to improve operations. Evidence of these possibilities can be found in the adoption of this technology by many agencies today and the cooperation of several law enforcement agencies in both participating in the pilot efforts and sharing of information about their own experiences in efforts undertaken separately.

  1. Dam Safety Regulation (Mississippi)

    Broader source: Energy.gov [DOE]

    The purpose of the Dam Safety Regulation is to ensure that all dams constructed in the state of Mississippi are permitted and thus do not potentially harm wildlife, water supplies and property. ...

  2. Dam Safety Regulations (Connecticut)

    Broader source: Energy.gov [DOE]

    All dams, except those owned by the U.S., are under the jurisdiction of these regulations. These dams will be classified by hazard rating, and may be subject to periodic inspections. The...

  3. Of Refrigerators & Regulations

    Broader source: Energy.gov [DOE]

    Editor's Note: This entry has been cross-posted from The White House Blog. The President took a moment during his speech to put the debate over regulation in a different perspective.

  4. Sulfur Dioxide Regulations (Ohio)

    Broader source: Energy.gov [DOE]

    This chapter of the law establishes that the Ohio Environmental Protection Agency provides sulfur dioxide emission limits for every county, as well as regulations for the emission, monitoring and...

  5. Underground Storage Tank Regulations

    Broader source: Energy.gov [DOE]

    The Underground Storage Tank Regulations is relevant to all energy projects that will require the use and building of pipelines, underground storage of any sorts, and/or electrical equipment. The...

  6. Regulation 2: Student Discipline REGULATION 2: STUDENT DISCIPLINE

    E-Print Network [OSTI]

    Sussex, University of

    Regulation 2: Student Discipline 6 REGULATION 2: STUDENT DISCIPLINE 1. Definitions In this Regulation: The University means the University of Sussex. Council means Council of the University. Senate to the regulations of the affiliated institution, and excluding students in attendance at the Brighton and Sussex

  7. SB 4 Well Stimulation Treatment Regulations Text of Proposed Regulations

    E-Print Network [OSTI]

    surveys; routine activities that do not affect the integrity of the well or the formation; the removal SB 4 Well Stimulation Treatment Regulations Text of Proposed Regulations Page 1 of 13 SB 4 WELL STIMULATION TREATMENT REGULATIONS TEXT OF PROPOSED REGULATIONS Added text is shown in underline

  8. An Off-Chip Capacitor Free Low Dropout Regulator with PSR Enhancement at Higher Frequencies

    E-Print Network [OSTI]

    Gopalraju, Seenu

    2012-02-14T23:59:59.000Z

    of the requirements for the degree of MASTER OF SCIENCE Approved by: Chair of Committee, Edgar Sanchez-Sinencio Committee Members, Kamran Entesari Shankar P. Bhattacharyya Duncan Henry M. Walker Head of Department, Costas Georghiades December 2010... Sanchez-Sinencio Low Dropout Regulators (LDOs) are extensively used in portable applications like mobile phones, PDAs and notebooks. These portable applications demand high power efficiency and low output voltage ripple. In addition to these...

  9. Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions

    E-Print Network [OSTI]

    Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 19-1 High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 1. DC Properties of Modern Filled Epoxy Insulation Academic and Research Staff Dr. Chathan Cooke Sponsor

  10. Public Opinions of Building Additional High-Voltage Electric Power Lines

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    Public Opinions of Building Additional High-Voltage Electric Power Lines A Report to the National-Voltage Electric Power Lines: A Report to the National Science Foundation and the Electric Power Research Center to build new power lines. Residents living in counties with planned routes for new transmission lines

  11. Wind Farm Reactive Support and Voltage Control Daniel F. Opila Abdi M. Zeynu Ian A. Hiskens

    E-Print Network [OSTI]

    Hiskens, Ian A.

    Wind Farm Reactive Support and Voltage Control Daniel F. Opila Abdi M. Zeynu Ian A. Hiskens Abstract--Wind farms typically contain a variety of voltage control equipment including tap or wind farm; it is desirable to treat all the equipment as an integrated system rather than independent

  12. High voltage transformers. (Latest citations from the Inspec database). NewSearch

    SciTech Connect (OSTI)

    Not Available

    1994-11-01T23:59:59.000Z

    The bibliography contains citations concerning materials and performance of insulators used for high voltage transformers. Topics examine use of mica-fibers, gases, mica filled epoxies, and ceramics. Effects of insulation aging are reviewed, and acceptance testing of high voltage power transformers and apparatus is also examined. (Contains a minimum of 104 citations and includes a subject term index and title list.)

  13. High voltage transformers. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search

    SciTech Connect (OSTI)

    NONE

    1996-08-01T23:59:59.000Z

    The bibliography contains citations of selected patents concerning high voltage transformers. Included are hybrid, video, rectifier, x-ray diagnostic generator, temperature control system, and printed circuit wound high voltage transformers. The fabrication, assembly, and testing of these transformers are also presented. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  14. High voltage transformers. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search

    SciTech Connect (OSTI)

    NONE

    1995-07-01T23:59:59.000Z

    The bibliography contains citations of selected patents concerning high voltage transformers. Included are hybrid, video, rectifier, x-ray diagnostic generator, temperature control system, and printed circuit wound high voltage transformers. The fabrication, assembly, and testing of these transformers are also presented. (Contains 50-250 citations and includes a subject term index and title list.)

  15. Figure 1. Voltage margins to manage fluctuations. AUDIT: Stress Testing the Automatic Way

    E-Print Network [OSTI]

    John, Lizy Kurian

    .govindan}@amd.com Abstract--Sudden variations in current (large di/dt) can lead to significant power supply voltage droops; stressmark generation; voltage droop; power distribution network; low power; genetic algorithm; hardware][12][13]. Other work addressed mitigating droops that occur due to various architectural events [3

  16. A Voltage Controlled Nano Addressing Circuit University of Texas, San Antonio TX 78249, USA,

    E-Print Network [OSTI]

    Liu, Bao

    A Voltage Controlled Nano Addressing Circuit Bao Liu University of Texas, San Antonio TX 78249, USA, Abstract. A voltage controlled nano addressing circuit is proposed, which (1) improves yield and enables aggressive scaling with no require- ment of precise layout design, (2) achieves precision of addressing

  17. Journal of Power Sources 167 (2007) 1117 Voltage reversal during microbial fuel cell stack operation

    E-Print Network [OSTI]

    2007-01-01T23:59:59.000Z

    Journal of Power Sources 167 (2007) 11­17 Voltage reversal during microbial fuel cell stack February 2007; accepted 9 February 2007 Available online 20 February 2007 Abstract Microbial fuel cells Elsevier B.V. All rights reserved. Keywords: Microbial fuel cell; Voltage reversal; Stack; Direct electron

  18. A New Bifurcation Analysis for Power System Dynamic Voltage Stability Studies

    E-Print Network [OSTI]

    a specific system configuration and the operation condition. For a power system, the typical state variables are the time dependent generator voltages (For different generator models, the variables of generator voltages as the variables of the exciter, speed governor and so on; sometimes the dynamics of the load behavior will also

  19. Impact of High Wind Penetration on the Voltage Profile of Distribution Systems

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    of wind generator the voltage of the system may become lower than acceptable voltage level due and wind generator is presented. Simulation results are given in Section III which shows the impact of high--In this paper, simulation results showing the effect of lower and higher penetration of distributed wind

  20. An Ensemble Empirical Mode Decomposition Approach for Voltage Sag Detection in a Smart Grid Context

    E-Print Network [OSTI]

    Brest, Université de

    An Ensemble Empirical Mode Decomposition Approach for Voltage Sag Detection in a Smart Grid Context Yassine Amirat1,2 , Mohamed Benbouzid2 , Tianzhen Wang3 and Sylvie Turri2 Abstract­Smart grids have become, using the instantaneous power for voltage sags detection in smart grids. Copyright © 2013 Praise Worthy

  1. A LOW POWER SCHEDULING SCHEME WITH RESOURCES OPERATING AT MULTIPLE VOLTAGES

    E-Print Network [OSTI]

    Kambhampati, Subbarao

    A LOW POWER SCHEDULING SCHEME WITH RESOURCES OPERATING AT MULTIPLE VOLTAGES Ali Manzak and Chaitali Tempe, AZ 85287­5706 istanbul@asu.edu, chaitali@asu.edu ABSTRACT This paper presents a new resource the resources operate at multi­ ple voltages. The scheduling scheme is list based. In each control cycle

  2. Supply Voltage Degradation Aware Analytical Placement Andrew B. Kahng Bao Liu Qinke Wang

    E-Print Network [OSTI]

    Liu, Bao

    Supply Voltage Degradation Aware Analytical Placement Andrew B. Kahng Bao Liu Qinke Wang Computer@cs.ucsd.edu} Abstract Increasingly significant power/ground supply voltage degradation in nanometer VLSI designs leads to system per- formance degradation and even malfunction. Existing tech- niques focus on design

  3. Supervisory hybrid model predictive control for voltage stability of power networks

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Supervisory hybrid model predictive control for voltage stability of power networks R.R. Negenborn voltage control problems in electric power networks have stimulated the interest for the imple- mentation dynamics to restore power consumption beyond the capability of the transmission and generation system

  4. Pipeline Strategy for Improving Optimal Energy Efficiency in Ultra-Low Voltage Design

    E-Print Network [OSTI]

    Kambhampati, Subbarao

    Pipeline Strategy for Improving Optimal Energy Efficiency in Ultra-Low Voltage Design Mingoo Seok for the ultra low voltage regime. Based on an analytical model and simulations, we propose a pipelining technique that provides higher energy effi- ciency and performance than conventional approaches to ultra low

  5. An ultra-low voltage high gain operational transconductance amplifier for biomedical

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    An ultra-low voltage high gain operational transconductance amplifier for biomedical applications that work at ultra low voltage power supply. Moreover, low power dissipation is essential in these systems dissipation is also proposed in [5]. Differential pairs are commonly used as input stages, in an ultra-low

  6. Variation-aware Clock Network Design Methodology for Ultra-Low Voltage (ULV) Circuits

    E-Print Network [OSTI]

    Lim, Sung Kyu

    Variation-aware Clock Network Design Methodology for Ultra-Low Voltage (ULV) Circuits Xin Zhao networks for ultra-low voltage (ULV) circuits. We show that both clock slew and skew play important roles) at comparable or even higher Fmax compared with the existing methods. Keywords--clock network design, ultra-low

  7. Mitigation of Voltage and Current Harmonics in Grid-Connected Microgrids

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    Mitigation of Voltage and Current Harmonics in Grid-Connected Microgrids Mehdi Savaghebi1 , Josep M-connected microgrids. Two modes of compensation are considered, i.e. voltage and current compensation modes-electronic interface converter to the utility grid or microgrid. Microgrid is a local grid consisting of DGs, energy

  8. Radio-frequency powered glow discharge device and method with high voltage interface

    DOE Patents [OSTI]

    Duckworth, Douglas C. (Knoxville, TN); Marcus, R. Kenneth (Clemson, SC); Donohue, David L. (Vienna, AT); Lewis, Trousdale A. (Oak Ridge, TN)

    1994-01-01T23:59:59.000Z

    A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components.

  9. Radio-frequency powered glow discharge device and method with high voltage interface

    DOE Patents [OSTI]

    Duckworth, D.C.; Marcus, R.K.; Donohue, D.L.; Lewis, T.A.

    1994-06-28T23:59:59.000Z

    A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components. 11 figures.

  10. Low Power Discrete Voltage Assignment Under Clock Skew , Jian Sun2

    E-Print Network [OSTI]

    Zhou, Hai

    assignment problem by formulating it into an Integer Linear Programming (ILP) with inequalities representingLow Power Discrete Voltage Assignment Under Clock Skew Scheduling Li Li1 , Jian Sun2 , Yinghai Lu1 Abstract--Multiple Supply Voltage (MSV) assignment has emerged as an appealing technique in low power IC

  11. Importance of the Equlibrium Node in Preventing the Voltage Collapse Occurs in the Wind Power System

    E-Print Network [OSTI]

    Lavaei, Javad

    Importance of the Equlibrium Node in Preventing the Voltage Collapse Occurs in the Wind Power collapse will occurs in a wind power system is discussed next. The method of power flow calculation is the specific analysis of a given simplified wind power system. Keywords--voltage collapse; Newton

  12. TCSC as a Transient Voltage Stabilizing Controller Garng Huang and Tong Zhu

    E-Print Network [OSTI]

    to enhance the voltage stability by changing the reactive power distribution in the power system. Authors and operated by some utilities [1,2]. The primary uses of TCSC are to enhance the power system angle stability on the small signal voltage stability for a simple power system with an infinitive bus and a dynamic load

  13. A Two-Stage Distributed Architecture for Voltage Control in Power Distribution Systems

    E-Print Network [OSTI]

    Hadjicostis, Christoforos

    violations and shapes the voltage profile in radial distribution networks, even in the presence [6]--and the Equinox house [7] are examples of residential PV installations capable of producing, the additional power demand introduced by massive charging of PHEVs can potentially cause unacceptable voltage

  14. VOLTAGE COLLAPSE AND TRANSIENT ENERGY FUNCTION ANALYSES OF AC/DC SYSTEMS

    E-Print Network [OSTI]

    Cañizares, Claudio A.

    for power system dynamic models, including a third order representation of high voltage direct current (HVDC power limits, HVDC firing angle limits and voltage dependent current order limits (VDCOL) are shown the derivation of individual component Lyapunov functions for simplified models of HVDC links connected

  15. Voltage grid support of DFIG wind turbines during grid faults Anca D. Hansen1

    E-Print Network [OSTI]

    Voltage grid support of DFIG wind turbines during grid faults Anca D. Hansen1 , Gabriele Michalke2 Abstract The fault ride-through and grid support capabilities of the doubly fed induction generator (DFIG and their contribution to support the grid, i.e. to the voltage control in the power system, during grid faults

  16. A New Thermal-Conscious System-Level Methodology for Energy-Efficient Processor Voltage Selection

    E-Print Network [OSTI]

    Wang, Yu

    A New Thermal-Conscious System-Level Methodology for Energy-Efficient Processor Voltage Selection a thermal-conscious system-level methodology to make energy-efficient voltage selection (VS) for nanometer), thermal resistance, are integrated and considered in our system models, and their impacts on energy

  17. Low-profile high-voltage compact gas switch

    SciTech Connect (OSTI)

    Goerz, D.A.; Wilson, M.J.; Speer, R.D.

    1997-06-30T23:59:59.000Z

    This paper discusses the development and testing of a low-profile, high-voltage, spark-gap switch designed to be closely coupled with other components into an integrated high-energy pulsed-power source. The switch is designed to operate at 100 kV using SF6 gas pressurized to less than 0.7 MPa. The volume of the switch cavity region is less than 1.5 cm3, and the field stress along the gas-dielectric interface is as high as 130 kV/cm. The dielectric switch body has a low profile that is only I -cm tall at its greatest extent and nominally 2-mm thick over most of its area. This design achieves a very low inductance of less than 5 nH, but results in field stresses exceeding 500 kV/cm in the dielectric material. Field modeling was done to determine the appropriate shape for the highly stressed insulator and electrodes, and special manufacturing techniques were employed to mitigate the usual mechanisms that induce breakdown and failure in solid dielectrics. Static breakdown tests verified that the switch operates satisfactorily at 100 kV levels. The unit has been characterized with different shaped electrodes having nominal gap spacings of 2.0, 2.5, and 3.0 mm. The relationship between self-break voltage and operating pressure agrees well with published data on gas properties, accounting for the field enhancements of the electrode shapes being used. Capacitor discharge tests in a low inductance test fixture exhibited peak currents up to 25 kA with characteristic frequencies of the ringdown circuit ranging from 10 to 20 MHz. The ringdown waveforms and scaling of measured parameters agree well with circuit modeling of the switch and test fixture. Repetitive operation has been demonstrated at moderate rep-rates up to 15 Hz, limited by the power supply being used. Preliminary tests to evaluate lifetime of the compact switch assembly have been encouraging. In one case, after more than 7,000 high-current ringdown tests with approximately 30 C of total charge transferred, the switch continued to operate satisfactorily with no apparent tracking or deterioration of the insulator.

  18. Switch contact device for interrupting high current, high voltage, AC and DC circuits

    DOE Patents [OSTI]

    Via, Lester C.; Witherspoon, F. Douglas; Ryan, John M.

    2005-01-04T23:59:59.000Z

    A high voltage switch contact structure capable of interrupting high voltage, high current AC and DC circuits. The contact structure confines the arc created when contacts open to the thin area between two insulating surfaces in intimate contact. This forces the arc into the shape of a thin sheet which loses heat energy far more rapidly than an arc column having a circular cross-section. These high heat losses require a dramatic increase in the voltage required to maintain the arc, thus extinguishing it when the required voltage exceeds the available voltage. The arc extinguishing process with this invention is not dependent on the occurrence of a current zero crossing and, consequently, is capable of rapidly interrupting both AC and DC circuits. The contact structure achieves its high performance without the use of sulfur hexafluoride.

  19. DRAFT - DOE G 444.1-1, Guide on Preventing and Responding to All Forms of Violence in the Workplace

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    To ensure all sites have the tools to implement processes, we have created this guide. Each site is expected to develop its own site specific set of procedures/process to implement DOE Policy 444.1 Preventing and Responding to all forms of violence in the Workplace.

  20. Most impacts on wildlife will likely be indirect as wildlife species respond to slow changes in plant

    E-Print Network [OSTI]

    New Hampshire, University of

    : status and concerns. Ecological relationships of winter ticks, moose, and climate change. Moose) changes · "moose sickness" · deer keds · forestry impacts ("sprucification") Russia: poaching#12; Most impacts on wildlife will likely be indirect as wildlife species respond to slow changes