Powered by Deep Web Technologies
Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Toward atomic resolution diffractive imaging of isolated molecules with x-ray free-electron lasers  

E-Print Network [OSTI]

We give a detailed account of the theoretical analysis and the experimental results of an x-ray-diffraction experiment on quantum-state selected and strongly laser-aligned gas-phase ensembles of the prototypical large asymmetric rotor molecule 2,5-diiodobenzonitrile, performed at the Linac Coherent Light Source [Phys. Rev. Lett. 112, 083002 (2014)]. This experiment is the first step toward coherent diffractive imaging of structures and structural dynamics of isolated molecules at atomic resolution, i. e., picometers and femtoseconds, using x-ray free-electron lasers.

Stern, Stephan; Filsinger, Frank; Rouzée, Arnaud; Rudenko, Artem; Johnsson, Per; Martin, Andrew V; Barty, Anton; Bostedt, Christoph; Bozek, John D; Coffee, Ryan N; Epp, Sascha; Erk, Benjamin; Foucar, Lutz; Hartmann, Robert; Kimmel, Nils; Kühnel, Kai-Uwe; Maurer, Jochen; Messerschmidt, Marc; Rudek, Benedikt; Starodub, Dmitri G; Thøgersen, Jan; Weidenspointner, Georg; White, Thomas A; Stapelfeldt, Henrik; Rolles, Daniel; Chapman, Henry N; Küpper, Jochen

2014-01-01T23:59:59.000Z

2

Laser Doppler field sensor for high resolution flow velocity imaging without camera  

SciTech Connect (OSTI)

In this paper we present a laser sensor for highly spatially resolved flow imaging without using a camera. The sensor is an extension of the principle of laser Doppler anemometry (LDA). Instead of a parallel fringe system, diverging and converging fringes are employed. This method facilitates the determination of the tracer particle position within the measurement volume and leads to an increased spatial and velocity resolution compared to conventional LDA. Using a total number of four fringe systems the flow is resolved in two spatial dimensions and the orthogonal velocity component. Since no camera is used, the resolution of the sensor is not influenced by pixel size effects. A spatial resolution of 4 {mu}m in the x direction and 16 {mu}m in the y direction and a relative velocity resolution of 1x10{sup -3} have been demonstrated up to now. As a first application we present the velocity measurement of an injection nozzle flow. The sensor is also highly suitable for applications in nano- and microfluidics, e.g., for the measurement of flow rates.

Voigt, Andreas; Bayer, Christian; Shirai, Katsuaki; Buettner, Lars; Czarske, Juergen

2008-09-20T23:59:59.000Z

3

Analysis of high resolution scatter images from laser damage experiments performed on KDP  

SciTech Connect (OSTI)

Interest in producing high damage threshold KH{sub 2}PO{sub 4} (KDP) and (D{sub x}H{sub 1-x}){sub 2}PO{sub 4} (KD*P, DKDP) for optical switching and frequency conversion applications is being driven by the system requirements for the National Ignition Facility (NIF) at Lawrence Livermore National Lab (LLNL). Historically, the path to achieving higher damage thresholds has been to improve the purity of crystal growth solutions. Application of advanced filtration technology has increased the damage threshold, but gives little insight into the actual mechanisms of laser damage. We have developed a laser scatter diagnostic to better study bulk defects and laser damage mechanisms in KDP and KD*P crystals. This diagnostic consists of a cavity doubled, kilohertz class, Nd:YLF laser (527 nm) and high dynamic range CCD camera which allows imaging of bulk scatter signals. With it, we have performed damage tests at 355 nm on four different {open_quotes}vintages{close_quotes} of KDP crystals, concentrating on crystals produced via fast growth methods. We compare the diagnostic`s resolution to LLNL`s standard damage detection method of 100X darkfield microscopy and discuss its impact on damage threshold determination. We have observed the disappearance of scatter sites upon exposure to subthreshold irradiation. In contrast, we have seen scatterers appear where none previously existed. This includes isolated, large (high signal) sites as well as multiple small scatter sites which appear at fluences above 7 J/cm{sup 2} (fine tracking). However, we have not observed a strong correlation of preexisting scatter sites and laser damage sites. We speculate on the connection between the laser-induced disappearance of scatter sites and the observed increase in damage threshold with laser conditioning.

Runkel, M.; Woods, B.; Yan, M. [and others

1996-01-05T23:59:59.000Z

4

Speckle-free laser imaging  

E-Print Network [OSTI]

Many imaging applications require increasingly bright illumination sources, motivating the replacement of conventional thermal light sources with light emitting diodes (LEDs), superluminescent diodes (SLDs) and lasers. Despite their brightness, lasers and SLDs are poorly suited for full-field imaging applications because their high spatial coherence leads to coherent artifacts known as speckle that corrupt image formation. We recently demonstrated that random lasers can be engineered to provide low spatial coherence. Here, we exploit the low spatial coherence of specifically-designed random lasers to perform speckle-free full-field imaging in the setting of significant optical scattering. We quantitatively demonstrate that images generated with random laser illumination exhibit higher resolution than images generated with spatially coherent illumination. By providing intense laser illumination without the drawback of coherent artifacts, random lasers are well suited for a host of full-field imaging applicatio...

Redding, Brandon; Cao, Hui

2011-01-01T23:59:59.000Z

5

High Spatial Resolution Thermal Imaging of Multiple Section Semiconductor Lasers Ali Shakouri*  

E-Print Network [OSTI]

and peak wavelength characteristics of active optoelectronic devices. In this paper we describe how for optoelectronic devices such as laser sources, switching/routing elements, and detectors. This is especially true (TE) coolers. However since their integration with optoelectronic devices is difficult [1

6

Lasers, Electron Beams and New Years Resolutions | Department...  

Broader source: Energy.gov (indexed) [DOE]

Lasers, Electron Beams and New Years Resolutions Lasers, Electron Beams and New Years Resolutions March 2, 2011 - 3:43pm Addthis Charles Rousseaux Charles Rousseaux Senior Writer,...

7

Atomic resolution images of graphite in air  

SciTech Connect (OSTI)

One sample used for proof of operation for atomic resolution in STM is highly oriented pyrolytic graphite (HOPG). This sample has been imaged with many different STM`s obtaining similar results. Atomic resolution images of HOPG have now been obtained using an STM designed and built at the Precision Engineering Center. This paper discusses the theoretical predictions and experimental results obtained in imaging of HOPG.

Grigg, D.A.; Shedd, G.M.; Griffis, D.; Russell, P.E.

1988-12-01T23:59:59.000Z

8

Blind assessment of localisation microscope image resolution  

E-Print Network [OSTI]

localisation precisions and densities. Methods By analysing localisation microscopy as a statistical method of Density Estimation, we present a method that produces a blind estimate of the resolution in a super-resolved image. This estimate is derived directly...

Rees, Eric J; Erdelyi, Miklos; Pinotsi, Dorothea; Knight, Alex; Metcalf, Daniel; Kaminski, Clemens F

2012-12-10T23:59:59.000Z

9

Image Resolution in Scanning Transmission Electron Microscopy  

SciTech Connect (OSTI)

Digital images captured with electron microscopes are corrupted by two fundamental effects: shot noise resulting from electron counting statistics and blur resulting from the nonzero width of the focused electron beam. The generic problem of computationally undoing these effects is called image reconstruction and for decades has proved to be one of the most challenging and important problems in imaging science. This proposal concerned the application of the Pixon method, the highest-performance image-reconstruction algorithm yet devised, to the enhancement of images obtained from the highest-resolution electron microscopes in the world, now in operation at Oak Ridge National Laboratory.

Pennycook, S. J.; Lupini, A.R.

2008-06-26T23:59:59.000Z

10

Interpreting atomic resolution spectroscopic images  

SciTech Connect (OSTI)

Core-loss electron energy loss spectroscopy is a powerful experimental tool providing information about electronic structure essential for understanding the properties of new and emerging materials. Here we show that the shape and width of spectroscopic images do not show a simple variation with binding energy, as commonly assumed. Rather they exhibit a complex dependence on the effective nonlocal scattering potential, and also on the dynamical channeling and absorption of the incident probe through the specimen. Consequently, in LaMnO$_3$, the low lying La N$_{4,5}$ edge at 99 eV can produce images of similar width to higher lying edges such as the O $K$ edge at 532 eV.

Oxley, Mark P [ORNL; Varela del Arco, Maria [ORNL; Pennycook, Timothy J [ORNL; van Benthem, Klaus [ORNL; Findlay, Scott D. [University of Melbourne, Australia; Allen, L. J. [University of Melbourne, Australia; Pennycook, Stephen J [ORNL

2007-01-01T23:59:59.000Z

11

High-Resolution Optical Coherence Tomography-Guided Laser Ablation of Surgical Tissue1  

E-Print Network [OSTI]

High-Resolution Optical Coherence Tomography-Guided Laser Ablation of Surgical Tissue1 Stephen A Hospital, Boston, Massachusetts 02114 Submitted for publication September 17, 1998 Background. Optical coherence tomography (OCT) is a compact high-speed imaging technology which uses infrared light to acquire

Boppart, Stephen

12

An Automated Platform for High-Resolution Tissue Imaging Using...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

entire image is acquired. The performance of the system is demonstrated by imaging rat brain tissue sections. High resolution mass analysis combined with MSMS experiments enabled...

13

Isotope specific resolution recovery image reconstruction in high resolution PET imaging  

SciTech Connect (OSTI)

Purpose: Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. Methods: In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. Results: The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Conclusions: Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution recovery image reconstruction. The benefits are expected to be more substantial for more energetic positron emitting isotopes such as Oxygen-15 and Rubidium-82.

Kotasidis, Fotis A. [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva, Switzerland and Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, M20 3LJ, Manchester (United Kingdom)] [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva, Switzerland and Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, M20 3LJ, Manchester (United Kingdom); Angelis, Georgios I. [Faculty of Health Sciences, Brain and Mind Research Institute, University of Sydney, NSW 2006, Sydney (Australia)] [Faculty of Health Sciences, Brain and Mind Research Institute, University of Sydney, NSW 2006, Sydney (Australia); Anton-Rodriguez, Jose; Matthews, Julian C. [Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, Manchester M20 3LJ (United Kingdom)] [Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, Manchester M20 3LJ (United Kingdom); Reader, Andrew J. [Montreal Neurological Institute, McGill University, Montreal QC H3A 2B4, Canada and Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King's College London, St. Thomas’ Hospital, London SE1 7EH (United Kingdom)] [Montreal Neurological Institute, McGill University, Montreal QC H3A 2B4, Canada and Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King's College London, St. Thomas’ Hospital, London SE1 7EH (United Kingdom); Zaidi, Habib [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva (Switzerland) [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva (Switzerland); Geneva Neuroscience Centre, Geneva University, CH-1205 Geneva (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, PO Box 30 001, Groningen 9700 RB (Netherlands)

2014-05-15T23:59:59.000Z

14

Image Forgery Detection Using Multi-Resolution Weber Local Descriptors  

E-Print Network [OSTI]

Image Forgery Detection Using Multi-Resolution Weber Local Descriptors Muhammad Hussain1 , Ghulam * ghulam@ksu.edu.sa Abstract-- In this paper, a multi-resolution Weber law descriptors (WLD) based image of the images. Keywords: image forgery detection, Weber local descriptor, splicing forgery, copy-move forgery

Bebis, George

15

Ultra-high resolution computed tomography imaging  

DOE Patents [OSTI]

A method for ultra-high resolution computed tomography imaging, comprising the steps of: focusing a high energy particle beam, for example x-rays or gamma-rays, onto a target object; acquiring a 2-dimensional projection data set representative of the target object; generating a corrected projection data set by applying a deconvolution algorithm, having an experimentally determined a transfer function, to the 2-dimensional data set; storing the corrected projection data set; incrementally rotating the target object through an angle of approximately 180.degree., and after each the incremental rotation, repeating the radiating, acquiring, generating and storing steps; and, after the rotating step, applying a cone-beam algorithm, for example a modified tomographic reconstruction algorithm, to the corrected projection data sets to generate a 3-dimensional image. The size of the spot focus of the beam is reduced to not greater than approximately 1 micron, and even to not greater than approximately 0.5 microns.

Paulus, Michael J. (Knoxville, TN); Sari-Sarraf, Hamed (Knoxville, TN); Tobin, Jr., Kenneth William (Harriman, TN); Gleason, Shaun S. (Knoxville, TN); Thomas, Jr., Clarence E. (Knoxville, TN)

2002-01-01T23:59:59.000Z

16

Laser focus compensating sensing and imaging device  

DOE Patents [OSTI]

A laser focus compensating sensing and imaging device permits the focus of a single focal point of different frequency laser beams emanating from the same source point. In particular it allows the focusing of laser beam originating from the same laser device but having differing intensities so that a low intensity beam will not convert to a higher frequency when passing through a conversion crystal associated with the laser generating device. The laser focus compensating sensing and imaging device uses a Cassegrain system to fold the lower frequency, low intensity beam back upon itself so that it will focus at the same focal point as a high intensity beam. An angular tilt compensating lens is mounted about the secondary mirror of the Cassegrain system to assist in alignment. In addition cameras or CCD's are mounted with the primary mirror to sense the focused image. A convex lens is positioned co-axial with the Cassegrain system on the side of the primary mirror distal of the secondary for use in aligning a target with the laser beam. A first alternate embodiment includes a Cassegrain system using a series of shutters and an internally mounted dichroic mirror. A second alternate embodiment uses two laser focus compensating sensing and imaging devices for aligning a moving tool with a work piece.

Vann, C.S.

1993-08-31T23:59:59.000Z

17

atomic resolution imaging: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

annular dark-field STEM Dunin-Borkowski, Rafal E. 6 Crystal structure retrieval by maximum entropy analysis of atomic resolution incoherent images Materials Science Websites...

18

atomic resolution images: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

annular dark-field STEM Dunin-Borkowski, Rafal E. 6 Crystal structure retrieval by maximum entropy analysis of atomic resolution incoherent images Materials Science Websites...

19

High vertical resolution crosswell seismic imaging  

DOE Patents [OSTI]

A method for producing high vertical resolution seismic images from crosswell data is disclosed. In accordance with one aspect of the disclosure, a set of vertically spaced, generally horizontally extending continuous layers and associated nodes are defined within a region between two boreholes. The specific number of nodes is selected such that the value of a particular characteristic of the subterranean region at each of the nodes is one which can be determined from the seismic data. Once values are established at the nodes, values of the particular characteristic are assigned to positions between the node points of each layer based on the values at node within that layer and without regard to the values at node points within any other layer. A seismic map is produced using the node values and the assigned values therebetween. In accordance with another aspect of the disclosure, an approximate model of the region is established using direct arrival traveltime data. Thereafter, the approximate model is adjusted using reflected arrival data. In accordance with still another aspect of the disclosure, correction is provided for well deviation. An associated technique which provides improvements in ray tracing is also disclosed.

Lazaratos, Spyridon K. (Houston, TX)

1999-12-07T23:59:59.000Z

20

A low-cost, high-resolution, video-rate imaging optical radar  

SciTech Connect (OSTI)

Sandia National Laboratories has developed a unique type of portable low-cost range imaging optical radar (laser radar or LADAR). This innovative sensor is comprised of an active floodlight scene illuminator and an image intensified CCD camera receiver. It is a solid-state device (no moving parts) that offers significant size, performance, reliability, and simplicity advantages over other types of 3-D imaging sensors. This unique flash LADAR is based on low cost, commercially available hardware, and is well suited for many government and commercial uses. This paper presents an update of Sandia`s development of the Scannerless Range Imager technology and applications, and discusses the progress that has been made in evolving the sensor into a compact, low, cost, high-resolution, video rate Laser Dynamic Range Imager.

Sackos, J.T.; Nellums, R.O.; Lebien, S.M.; Diegert, C.F. [Sandia National Labs., Albuquerque, NM (United States); Grantham, J.W.; Monson, T. [Air Force Research Lab., Eglin AFB, FL (United States)

1998-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Thin, Free-Standing Films For High Resolution Neutron Imaging.  

E-Print Network [OSTI]

??Thin, free-standing boro-phosphosilicate glass (BPSG) films were fabricated at PSU Nanofab to serve as prototype neutron converters for a proposed high resolution neutron imaging system… (more)

Trivelpiece, Cory

2010-01-01T23:59:59.000Z

22

High-resolution mapping of quantum efficiency of silicon photodiode via optical-feedback laser microthermography  

SciTech Connect (OSTI)

We map the external quantum efficiency (QE) distribution of a silicon photodiode (PD) sample via a thermographic imaging technique based on optical-feedback laser confocal microscopy. An image pair consisting of the confocal reflectance image and the 2D photocurrent map is simultaneously acquired to delineate the following regions of interest on the sample: the substrate, the n-type region, the pn overlay, and the bonding pad. The 2D QE distribution is derived from the photocurrent map to quantify the optical performance of these sites. The thermal integrity of the sample is then evaluated by deriving the rate of change of QE with temperature T at each point on the silicon PD. These gradient maps function not only as stringent measures of local thermal QE activity but they also expose probable defect locations on the sample at high spatial resolution - a capability that is not feasible with existing bulk measurement techniques.

Cemine, Vernon Julius; Blanca, Carlo Mar; Saloma, Caesar

2006-09-20T23:59:59.000Z

23

High resolution resonance ionization imaging detector and method  

DOE Patents [OSTI]

A resonance ionization imaging device (RIID) and method for imaging objects using the RIID are provided, the RIID system including a RIID cell containing an ionizable vapor including monoisotopic atoms or molecules, the cell being positioned to intercept scattered radiation of a resonance wavelength .lambda..sub.1 from the object which is to be detected or imaged, a laser source disposed to illuminate the RIID cell with laser radiation having a wavelength .lambda..sub.2 or wavelengths .lambda..sub.2, .lambda..sub.3 selected to ionize atoms in the cell that are in an excited state by virtue of having absorbed the scattered resonance laser radiation, and a luminescent screen at the back surface of the RIID cell which presents an image of the number and position of charged particles present in the RIID cell as a result of the ionization of the excited state atoms. The method of the invention further includes the step of initially illuminating the object to be detected or imaged with a laser having a wavelength selected such that the object will scatter laser radiation having the resonance wavelength .lambda..sub.1.

Winefordner, James D. (Gainesville, FL); Matveev, Oleg I. (Gainesville, FL); Smith, Benjamin W. (Gainesville, FL)

1999-01-01T23:59:59.000Z

24

High Resolution Backside Imaging and Thermography using a Numerical Aperture Increasing Lens  

E-Print Network [OSTI]

High Resolution Backside Imaging and Thermography using a Numerical Aperture Increasing Lens M. S, representing the highest resolution subsurface thermography to date. Keywords: thermal imaging, high

25

HRTEM Imaging of Atoms at Sub-Angstrom Resolution  

SciTech Connect (OSTI)

John Cowley and his group at Arizona State University pioneered the use of transmission electron microscopy (TEM) for high-resolution imaging. Images were achieved three decades ago showing the crystal unit cell content at better than 4 Angstrom resolution. This achievement enabled researchers to pinpoint the positions of heavy atom columns within the unit cell. Lighter atoms appear as resolution is improved to sub-Angstrom levels. Currently, advanced microscopes can image the columns of the light atoms (carbon, oxygen, nitrogen) that are present in many complex structures, and even the lithium atoms present in some battery materials. Sub-Angstrom imaging, initially achieved by focal-series reconstruction of the specimen exit surface wave, will become common place for next-generation electron microscopes with CS-corrected lenses and monochromated electron beams. Resolution can be quantified in terms of peak separation and inter-peak minimum, but the limits imposed on the attainable resolution by the properties of the micro-scope specimen need to be considered. At extreme resolution the ''size'' of atoms can mean that they will not be resolved even when spaced farther apart than the resolution of the microscope.

O'Keefe, Michael A.; Allard, Lawrence F.; Blom, Douglas A.

2005-04-06T23:59:59.000Z

26

Compact and mobile high resolution PET brain imager  

DOE Patents [OSTI]

A brain imager includes a compact ring-like static PET imager mounted in a helmet-like structure. When attached to a patient's head, the helmet-like brain imager maintains the relative head-to-imager geometry fixed through the whole imaging procedure. The brain imaging helmet contains radiation sensors and minimal front-end electronics. A flexible mechanical suspension/harness system supports the weight of the helmet thereby allowing for patient to have limited movements of the head during imaging scans. The compact ring-like PET imager enables very high resolution imaging of neurological brain functions, cancer, and effects of trauma using a rather simple mobile scanner with limited space needs for use and storage.

Majewski, Stanislaw (Yorktown, VA); Proffitt, James (Newport News, VA)

2011-02-08T23:59:59.000Z

27

Towards wide-field high-resolution retinal imaging  

E-Print Network [OSTI]

Adaptive optical correction is an efficient technique to obtain high-resolution images of the retinal surface. A main limitation of adaptive optical correction, however, is the small size of the corrected image. For medical purposes it is important to increase the size of the corrected images. This can be done through composite imaging, but a major difficulty is then the introduction of reconstruction artifacts. Another approach is multi-conjugate adaptive optics. MCAO comes in two flavors. The star- oriented approach has been demonstrated on the eye and allows to increase the diameter of the corrected image by a factor of approximately 2-3. Difficulties in the tomographic reconstruction precludes the correction of larger fields. Here we have investigate the possibility to apply a layer-oriented MCAO approach to retinal imaging.

Kellerer, Aglae

2015-01-01T23:59:59.000Z

28

Fish embryo multimodal imaging by laser Doppler digital holography  

E-Print Network [OSTI]

A laser Doppler imaging scheme combined to an upright microscope is proposed. Quantitative Doppler imaging in both velocity norm and direction, as well as amplitude contrast of either zebrafish flesh or vasculature is demonstrated.

Verrier, Nicolas; Picart, Pascal; Gross, Michel

2015-01-01T23:59:59.000Z

29

Nonlinear formation of holographic images of obscurations in laser beams  

E-Print Network [OSTI]

Nonlinear formation of holographic images of obscurations in laser beams C. Clay Widmayer, David of obscurations in laser beams. The predictions of the model are found to be in good agreement with measurements the intensity and fluence of the beam at each component in the laser chain. Dam- age threats to the system can

30

Unsupervised Feature Learning for High-Resolution Satellite Image Classification  

SciTech Connect (OSTI)

The rich data provided by high-resolution satellite imagery allow us to directly model geospatial neighborhoods by understanding their spatial and structural patterns. In this paper we explore an unsupervised feature learning approach to model geospatial neighborhoods for classification purposes. While pixel and object based classification approaches are widely used for satellite image analysis, often these approaches exploit the high-fidelity image data in a limited way. In this paper we extract low-level features to characterize the local neighborhood patterns. We exploit the unlabeled feature measurements in a novel way to learn a set of basis functions to derive new features. The derived sparse feature representation obtained by encoding the measured features in terms of the learned basis function set yields superior classification performance. We applied our technique on two challenging image datasets: ORNL dataset representing one-meter spatial resolution satellite imagery representing five land-use categories and, UCMERCED dataset consisting of 21 different categories representing sub-meter resolution overhead imagery. Our results are highly promising and, in the case of UCMERCED dataset we outperform the best results obtained for this dataset. We show that our feature extraction and learning methods are highly effective in developing a detection system that can be used to automatically scan large-scale high-resolution satellite imagery for detecting large-facility.

Cheriyadat, Anil M [ORNL

2013-01-01T23:59:59.000Z

31

3D Laser Imaging at Highway Speed Kelvin CP Wang  

E-Print Network [OSTI]

3D Laser Imaging at Highway Speed Kelvin CP Wang And the Team Formerly at the University Concrete Consortium Meeting Oklahoma City Sheraton Hotel #12;3D Laser Imaging for Pavements Mature Potential to Cover Most if Not All Data Collection on Pavement Surface How to Obtain True 1mm 3D Visual

32

Submillimeter-resolution radiography of shielded structures with laser-accelerated electron beams  

E-Print Network [OSTI]

Submillimeter-resolution radiography of shielded structures with laser-accelerated electron beams (Received 24 March 2010; published 14 October 2010) We investigate the use of energetic electron beams beam (with energy >100 MeV) was generated by the process of laser-wakefield acceleration through

Umstadter, Donald

33

A Steerable Laser System for Atmospheric Monitoring at the High Resolution Flys Eye  

E-Print Network [OSTI]

and radiometer . The energy 2 released into the sky is determined by multiplying this measurementOG 4.5.10 A Steerable Laser System for Atmospheric Monitoring at the High Resolution Flys Eye J. R. Mumford , R. C. Gray , L. R. Wiencke for the 1 1 1 High Resolution Flys Eye Collaboration 1. Physics

34

Final report: high resolution lensless 3D imaging of nanostructures with coherent x-rays  

SciTech Connect (OSTI)

Final report on the project "High resolution lensless 3D imaging of nanostructures with coherent x-rays"

Jacobsen, Chris

2014-12-07T23:59:59.000Z

35

Plume Image Profiling of UV Laser Desorbed Biomolecules  

SciTech Connect (OSTI)

An experimental system, based upon the techniques of UV and IR laser desorption with time of flight mass spectrometry, has been constructed to enable the production and characterization of neutral biomolecular targets. The feasibility of the laser desorption technique for the purpose of radiation interaction experiments is investigated here. Fluorescent dye tagging and laser induced fluorescence imaging has been used to help characterize the laser produced plumes of biomolecules revealing their spatial density profiles and temporal evolution. Peak target thicknesses of 2x10{sup 12} molecules cm{sup -2} were obtained 30 {mu}s after laser desorption.

Merrigan, T. L.; Hunniford, C.A.; McCullough, R. W. [Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast, UK, BT7 1NN (United Kingdom); Timson, D. J. [School of Biological Sciences, Queen's University Belfast, Belfast, UK, BT9 7BL (United Kingdom); Catney, M. [Andor Technology plc., 7 Millennium Way, Springvale Business Park, Belfast, UK, BT12 7AL (United Kingdom)

2008-12-08T23:59:59.000Z

36

Simultaneous High-Resolution 2-Dimensional Spatial and 1-Dimensional Picosecond Streaked X-ray Pinhole Imaging  

SciTech Connect (OSTI)

A Kentech x-ray streak camera was run at the LLNL Compact Multipulse Terawatt (COMET) laser to record simultaneous space- and time-resolved measurements of picosecond laser-produced plasmas. Four different x-ray energy channels were monitored using broad-band filters to record the time history of Cu targets heated at irradiances of 10{sup 16} - 10{sup 19} W/cm{sup 2}. Through the Cu filter channel, a time-resolution below 3ps was obtained. Additionally, an array of 10 {micro}m diameter pinholes was placed in front of the camera to produce multiple time-resolved x-ray images on the photocathode and time-integrated images on the phosphor with 10 and 15 times magnification, respectively, with spatial resolution of <13 {micro}m.

Steel, A B; Nagel, S R; Dunn, J; Baldis, H A

2012-05-03T23:59:59.000Z

37

Imaging System With Confocally Self-Detecting Laser.  

DOE Patents [OSTI]

The invention relates to a confocal laser imaging system and method. The system includes a laser source, a beam splitter, focusing elements, and a photosensitive detector. The laser source projects a laser beam along a first optical path at an object to be imaged, and modulates the intensity of the projected laser beam in response to light reflected from the object. A beam splitter directs a portion of the projected laser beam onto a photodetector. The photodetector monitors the intensity of laser output. The laser source can be an electrically scannable array, with a lens or objective assembly for focusing light generated by the array onto the object of interest. As the array is energized, its laser beams scan over the object, and light reflected at each point is returned by the lens to the element of the array from which it originated. A single photosensitive detector element can generate an intensity-representative signal for all lasers of the array. The intensity-representative signal from the photosensitive detector can be processed to provide an image of the object of interest.

Webb, Robert H. (Lincoln, MA); Rogomentich, Fran J. (Concord, MA)

1996-10-08T23:59:59.000Z

38

High resolution coherent diffractive imaging with a table-top extreme ultraviolet source  

SciTech Connect (OSTI)

We demonstrate a resolution of 45?nm with a sample size down to 3??m × 3??m is achieved in a short exposure time of 2?s, from the diffraction pattern generated by a table-top high harmonic source at around 30?nm. By using a narrow-bandwidth focusing mirror, the diffraction pattern's quality is improved and the required exposure time is significantly reduced. In order to obtain a high quality of the reconstructed image, the ratio of the beam size to the sample size and the curvature of the focused beam need to be considered in the reconstruction process. This new experimental scheme is very promising for imaging sub-10?nm scale objects with a table-top source based on a small inexpensive femtosecond laser system.

Vu Le, Hoang, E-mail: vuhoangle@swin.edu.au; Ba Dinh, Khuong; Hannaford, Peter; Van Dao, Lap [Centre for Quantum and Optical Science, Swinburne University of Technology, Melbourne 3122 (Australia)

2014-11-07T23:59:59.000Z

39

Atomic Resolution Coherent Diffractive Imaging and Ultrafast Science  

SciTech Connect (OSTI)

A major scientific challenge is determining the 3-D atomic structure of small nanostructures, including single molecules. Coherent diffractive imaging (CDI) is a promising approach. Recent progress has demonstrated coherent diffraction patterns can be recorded from individual nanostructures and phased to reconstruct their structure. However, overcoming the dose limit imposed by radiation damage is a major obstacle toward the full potential of CDI. One approach is to use ultrafast x-ray or electron pulses. In electron diffraction, amplitudes recorded in a diffraction pattern are unperturbed by lens aberrations, defocus, and other microscope resolution-limiting factors. Sub-A signals are available beyond the information limit of direct imaging. Significant contrast improvement is obtained compared to high-resolution electron micrographs. progress has also been made in developing time-resolved electron diffraction and imaging for the study of ultrafast dynamic processes in materials. This talk will cover these crosscutting issues and the convergence of electron and x-ray diffraction techniques toward structure determination of single molecules.

Zuo, Jian-min (University of Illinois) [University of Illinois

2011-01-12T23:59:59.000Z

40

Collimator application for microchannel plate image intensifier resolution improvement  

DOE Patents [OSTI]

A collimator is included in a microchannel plate image intensifier (MCPI). Collimators can be useful in improving resolution of MCPIs by eliminating the scattered electron problem and by limiting the transverse energy of electrons reaching the screen. Due to its optical absorption, a collimator will also increase the extinction ratio of an intensifier by approximately an order of magnitude. Additionally, the smooth surface of the collimator will permit a higher focusing field to be employed in the MCP-to-collimator region than is currently permitted in the MCP-to-screen region by the relatively rough and fragile aluminum layer covering the screen. Coating the MCP and collimator surfaces with aluminum oxide appears to permit additional significant increases in the field strength, resulting in better resolution.

Thomas, Stanley W. (Livermore, CA)

1996-02-27T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Collimator application for microchannel plate image intensifier resolution improvement  

DOE Patents [OSTI]

A collimator is included in a microchannel plate image intensifier (MCPI). Collimators can be useful in improving resolution of MCPIs by eliminating the scattered electron problem and by limiting the transverse energy of electrons reaching the screen. Due to its optical absorption, a collimator will also increase the extinction ratio of an intensifier by approximately an order of magnitude. Additionally, the smooth surface of the collimator will permit a higher focusing field to be employed in the MCP-to-collimator region than is currently permitted in the MCP-to-screen region by the relatively rough and fragile aluminum layer covering the screen. Coating the MCP and collimator surfaces with aluminum oxide appears to permit additional significant increases in the field strength, resulting in better resolution. 2 figs.

Thomas, S.W.

1996-02-27T23:59:59.000Z

42

Greenhouse Gas Laser Imaging Tomography Experiment (GreenLITE): Evaluation of a new method to look at high resolution spatial/temporal distributions of carbon over key sub km sites  

SciTech Connect (OSTI)

Recently a new laser based approach for measuring area with potential for producing 2D estimates of the concentration spatial distribution has been developed through a cooperative agreement with the National Energy and Technology Laboratory of the Department of Energy, Exelis Inc. and AER Inc. The new approach is based on a pair of continuous wave intensity modulated laser absorption spectrometer transceivers, combined with a series of retro reflectors located around the perimeter of the area being monitored. The main goal of this cooperative agreement is monitoring, reporting and verification for ground carbon capture and storage projects. The system was recently tested at the Zero Emission Research and Technology site in Bozeman, MT, with underground leak rates ranging from 0.1 – 0.3 metric ton per day (T/d), as well as a 0.8 T/d surface release. Over 200 hours of data were collected over a rectangular grid 180m x 200m between August 18th and September 9th. In addition, multiple days of in situ data were acquired for the same site, using a Licor gas analyzer systems. Initial comparisons between the laser-based system and the in situ agree very well. The system is designed to operate remotely and transmit the data via a 3G/4G connection along with weather data for the site. An all web-based system ingests the data, populates a database, performs the inversion to ppm CO2 using the Line-by-Line Radiative Transfer Model (LBLRTM), and displays plots and statistics for the retrieved data. We will present an overview of the GreenLITE measurement system, outline the retrieval and reconstruction approach, and discuss results from extensive field testing.

Dobler, Jeremy; Zaccheo, T. Scott; Blume, Nathan; Braun, Michael; Perninit, Timothy; McGregor, Doug; Botos, Chris; Dobeck, Laura

2015-01-01T23:59:59.000Z

43

Laser hazard analysis for LASIRIS Model MAG-501L-670M-1000-45[degree]-K diode laser associated with high resolution pulsed scanner.  

SciTech Connect (OSTI)

A laser hazard analysis and safety assessment was performed for the LASIRISTM Model MAG-501L-670M-1000-45o-K diode laser associated with the High Resolution Pulse Scanner based on the ANSI Standard Z136.1-2000, American National Standard for the Safe Use of Lasers and the ANSI Standard Z136.6-2000, American National Standard for the Safe Use of Lasers Outdoors. The laser was evaluated for both indoor and outdoor use.

Augustoni, Arnold L.

2004-11-01T23:59:59.000Z

44

High resolution photoelectron images and D{sup +} photofragment images following 532-nm photolysis of D{sub 2}  

SciTech Connect (OSTI)

The non-resonant ionization and dissociation of D{sub 2} by intense 532-nm laser light is studied by a variation of the ``Ion Imaging`` technique called ``Velocity Mapping``. Images of the both the photoelectrons and D{sup +} photofragments are obtained and analyzed at two different laser intensities. Results are compared to previous studies and several differences are discussed.

Chandler, D.W.; Neyer, D.W. [Sandia National Labs., Livermore, CA (United States); Heck, A.J. [Univ. of Warwick, Coventry (United Kingdom). Dept. of Chemistry

1998-01-01T23:59:59.000Z

45

Virtually distortion-free imaging system for large field, high resolution lithography  

DOE Patents [OSTI]

Virtually distortion free large field high resolution imaging is performed using an imaging system which contains large field distortion or field curvature. A reticle is imaged in one direction through the optical system to form an encoded mask. The encoded mask is then imaged back through the imaging system onto a wafer positioned at the reticle position.

Hawryluk, A.M.; Ceglio, N.M.

1993-01-05T23:59:59.000Z

46

High resolution neutron imaging of water in PEM fuel cells  

SciTech Connect (OSTI)

Optimal water management in Polymer Electrolyte Membrane (PEM) fuel cells is critical to improving the performance and durability of fuel cell systems especially during transient, start-up and shut-down operations. For example, while a high water content is desirable for improved membrane and catalyst ionomer conductivity, high water content can also block gas access to the triple-phase boundary resulting in lowered performance due to catalyst and gas diffusion layer (GDL) flooding. Visualizing liquid water by neutron imaging has been used over the past decade to study the water distribution inside operating fuel cells. In this paper, the results from our imaging at NIST using their recently installed higher resolution ({approx} 25 mm) Microchannel Plate (MCP) detector with a pixel pitch of 14.7 mm are presented. This detector is capable of quantitatively imaging the water inside the MEA (Membrane Electrode Assembly)/GDL (Gas Diffusion Layer) of working fuel cells and can provide the water profiles within these various components in addition to the channel water. Specially designed fuel cells (active area = 2.25 cm{sup 2}) have been used in order to take advantage of the full detector resolution. The cell design is illustrated in a figure where one of the current collector/end plates is shown. The serpentine pattern was machined into a block of aluminum and plated with nickel and then gold to form the flow field. The measurements were performed using beam no. 1 and aperture no. 2 with a fluence rate of 1.9 x 10{sup 6} neutrons cm{sup -2} sec{sup -1}. The cells were assembled with Gore{sup TM} Primea{sup R} MEAs and SGL Sigracet {sup R} 24 series GDLs (PRIMEA, GORE-SELECT and GORE are trademarks of W. L. Gore & Associates, Inc). All the cells were tested at 80 {sup o}C with 1.2 stoichiometry H{sub 2} and 2.0 stoichiometry air flows.

Mukundan, Rangachary [Los Alamos National Laboratory; Borup, Rodney L [Los Alamos National Laboratory; Davey, John R [Los Alamos National Laboratory; Spendelow, Jacob S [Los Alamos National Laboratory

2008-01-01T23:59:59.000Z

47

Sub 400 nm spatial resolution extreme ultraviolet holography with a table top laser  

E-Print Network [OSTI]

. J. E. Trebes, S. B. Brown, E. M. Campbell, D. L. Matthews, D. G. Nilson, G. F. Stone, and D. A Society of America OCIS codes: (090.0090) Holography; (100.2960) Image analysis References and Links 1. D, C. Jacobsen, E. Anderson, M. R. Howells, and D. P. Kern, "High resolution imaging by Fourier

Rocca, Jorge J.

48

High-resolution three-dimensional optical coherence tomography imaging of kidney microanatomy ex vivo  

E-Print Network [OSTI]

Optical coherence tomography (OCT) is an emerging medical imaging technology that enables high-resolution, noninvasive, cross-sectional imaging of microstructure in biological tissues in situ and in real time. When combined ...

Chen, Yu

49

SEX DIFFERENCES IN THE HUMAN CONNECTOME: 4-TESLA HIGH ANGULAR RESOLUTION DIFFUSION IMAGING (HARDI)  

E-Print Network [OSTI]

SEX DIFFERENCES IN THE HUMAN CONNECTOME: 4-TESLA HIGH ANGULAR RESOLUTION DIFFUSION IMAGING (HARDI diffusion imaging at 4 Tesla, we scanned 234 young adult twins and siblings (mean age: 23.4 ± 2.0 SD years

Thompson, Paul

50

Improving resolution and depth of astronomical observations via modern mathematical methods for image analysis  

E-Print Network [OSTI]

In the past years modern mathematical methods for image analysis have led to a revolution in many fields, from computer vision to scientific imaging. However, some recently developed image processing techniques successfully exploited by other sectors have been rarely, if ever, experimented on astronomical observations. We present here tests of two classes of variational image enhancement techniques: "structure-texture decomposition" and "super-resolution" showing that they are effective in improving the quality of observations. Structure-texture decomposition allows to recover faint sources previously hidden by the background noise, effectively increasing the depth of available observations. Super-resolution yields an higher-resolution and a better sampled image out of a set of low resolution frames, thus mitigating problematics in data analysis arising from the difference in resolution/sampling between different instruments, as in the case of EUCLID VIS and NIR imagers.

Castellano, Marco; Fontana, Adriano; Merlin, Emiliano; Pilo, Stefano; Falcone, Maurizio

2015-01-01T23:59:59.000Z

51

Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe  

DOE Patents [OSTI]

A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.

Majewski, Stanislaw (Yorktown, VA); Proffitt, James (Newport News, VA)

2010-12-28T23:59:59.000Z

52

Atomic Resolution Imaging and Quantification of Chemical Functionality of Surfaces  

SciTech Connect (OSTI)

The work carried out from 2006-2014 under DoE support was targeted at developing new approaches to the atomic-scale characterization of surfaces that include species-selective imaging and an ability to quantify chemical surface interactions with site-specific accuracy. The newly established methods were subsequently applied to gain insight into the local chemical interactions that govern the catalytic properties of model catalysts of interest to DoE. The foundation of our work was the development of three-dimensional atomic force microscopy (3D-AFM), a new measurement mode that allows the mapping of the complete surface force and energy fields with picometer resolution in space (x, y, and z) and piconewton/millielectron volts in force/energy. From this experimental platform, we further expanded by adding the simultaneous recording of tunneling current (3D-AFM/STM) using chemically well-defined tips. Through comparison with simulations, we were able to achieve precise quantification and assignment of local chemical interactions to exact positions within the lattice. During the course of the project, the novel techniques were applied to surface-oxidized copper, titanium dioxide, and silicon oxide. On these materials, defect-induced changes to the chemical surface reactivity and electronic charge density were characterized with site-specific accuracy.

Schwarz, Udo [Yale University

2014-12-10T23:59:59.000Z

53

Image resolution analysis: a new, robust approach to seismic survey design  

E-Print Network [OSTI]

?guration, parameters such as the structure and seismic velocity also in?uence image resolution. Understanding their e?ect on image quality, allows us to better interpret the resolution results for the surveys under examination. A salt model was used to simulate...

Tzimeas, Constantinos

2005-08-29T23:59:59.000Z

54

Sea Ice Mapping Using Enhanced Resolution Advanced Scatterometer Images Steven Reeves  

E-Print Network [OSTI]

Sea Ice Mapping Using Enhanced Resolution Advanced Scatterometer Images Steven Reeves A thesis Rights Reserved #12;ABSTRACT Sea Ice Mapping Using Enhanced Resolution Advanced Scatterometer Images Steven Reeves Department of Electrical and Computer Engineering Master of Science Sea ice is of great

Long, David G.

55

Near-field imaging of quantum cascade laser transverse modes  

E-Print Network [OSTI]

. Lahrech, R. Bachelot, P. Gleyzes, and A. C. Boccara, "Infrared-reflection-mode near-field microscopy using: We report near field imaging of the transverse lasing modes of quantum cascade lasers. A mid-infrared. Nagar, G. Fish, K. Lieberman, G. Eisenstein, A. Lewis, J. M. Nielsen, and A. Møeller-Larsen, "Near-infrared

56

Direct laser additive fabrication system with image feedback control  

DOE Patents [OSTI]

A closed-loop, feedback-controlled direct laser fabrication system is disclosed. The feedback refers to the actual growth conditions obtained by real-time analysis of thermal radiation images. The resulting system can fabricate components with severalfold improvement in dimensional tolerances and surface finish.

Griffith, Michelle L. (Albuquerque, NM); Hofmeister, William H. (Nashville, TN); Knorovsky, Gerald A. (Albuquerque, NM); MacCallum, Danny O. (Edgewood, NM); Schlienger, M. Eric (Albuquerque, NM); Smugeresky, John E. (Pleasanton, CA)

2002-01-01T23:59:59.000Z

57

LASER ULTRASONIC IMAGING FOR IMPACT DAMAGE VISUALIZATION IN COMPOSITE STRUCTURE  

E-Print Network [OSTI]

LASER ULTRASONIC IMAGING FOR IMPACT DAMAGE VISUALIZATION IN COMPOSITE STRUCTURE Chao Zhang1 , Jinhao Qiu1* , Hongli Ji1 1 State Key Laboratory of Mechanics and Control of Mechanical Structures ultrasonic scanning technique has great potential for damage evaluation in various applications. In order

Boyer, Edmond

58

Ultrafast imaging of complex systems in 3-D at near atomic resolution...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

on ultrafast timescales using extremely intense X-ray free-electron laser (XFEL) pulses. One important step toward ultrafast imaging of samples with a single X-ray shot is...

59

Scannerless laser range imaging using loss modulation  

DOE Patents [OSTI]

A scannerless 3-D imaging apparatus is disclosed which utilizes an amplitude modulated cw light source to illuminate a field of view containing a target of interest. Backscattered light from the target is passed through one or more loss modulators which are modulated at the same frequency as the light source, but with a phase delay .delta. which can be fixed or variable. The backscattered light is demodulated by the loss modulator and detected with a CCD, CMOS or focal plane array (FPA) detector to construct a 3-D image of the target. The scannerless 3-D imaging apparatus, which can operate in the eye-safe wavelength region 1.4-1.7 .mu.m and which can be constructed as a flash LADAR, has applications for vehicle collision avoidance, autonomous rendezvous and docking, robotic vision, industrial inspection and measurement, 3-D cameras, and facial recognition.

Sandusky, John V. (Albuquerque, NM)

2011-08-09T23:59:59.000Z

60

Design, assembly, and testing of a high-resolution relay lens used for holography with operation at both doubled and tripled Nd:YAG laser wavelengths  

SciTech Connect (OSTI)

The design and assembly of a nine-element lens that achieves >2000 1p/mm resolution at a 355-nm wavelength (ultraviolet) has been completed. By adding a doublet to this lens system, operation at a 532-nm wavelength (green) with > 1100 1p/mm resolution is achieved. This lens is used with high-power laser light to record holograms of fast-moving ejecta particles from a shocked metal surface located inside a test package. Part of the lens and the entire test package are under vacuum with a 1-cm air gap separation. Holograms have been recorded with both doubled and tripled Nd:YAG laser light. The UV operation is very sensitive to the package window's tilt. If this window is tilted by more than 0.1 degrees, the green operation performs with better resolution than that of the UV operation. The setup and alignment are performed with green light, but the dynamic recording can be done with either UV light or green light. A resolution plate can be temporarily placed inside the test package so that a television microscope located beyond the hologram position can archive images of resolution patterns that prove that the calibration wires., interference filter, holographic plate, and relay lenses are in their correct positions. Part of this lens is under vacuum, at the point where the laser illumination passes through a focus. Alignment and tolerancing of this high-resolution lens are presented. Resolution variation across the 12-mm field of view and throughout the 5-mm depth of field is discussed for both wavelengths.

Sorenson, Danny S [Los Alamos National Laboratory; Pazuchanics, Peter D [Los Alamos National Laboratory; Malone, Robert M [NSTEC; Cox, Brian C [NSTEC; Frogget, Brent C [NSTEC; Kaufman, Morris I [NSTEC; Capelle, Gene A [NSTEC/SB; Grover, M [NSTEC/SB; Stevens, Gerald D [NSTEC/SB; Turley, William D [NSTEC/SB

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

High resolution image reconstruction with constrained, total-variation minimization  

E-Print Network [OSTI]

in computed tomography (CT), see for example [1], because it is possible to account for noise in the data the resolution is arbitrarily high, because the system resolution is still limited by the discrete data sampling of the volume and ideal conditions of perfect data consistency: g = Xf, (1) where g represents the projection

Kurien, Susan

62

Cellular delivery and site-specific targeting of organic fluorophores for super-resolution imaging in living cells  

E-Print Network [OSTI]

Recent advances in super-resolution fluorescence microscopy have pushed the spatial resolution of biological imaging down to a few nanometers. The key element to the development of such imaging modality is synthetic organic ...

Uttamapinant, Chayasith

2013-01-01T23:59:59.000Z

63

Untangling the contributions of image charge and laser profile for optimal photoemission of high-brightness electron beams  

SciTech Connect (OSTI)

Using our model for the simulation of photoemission of high brightness electron beams, we investigate the virtual cathode physics and the limits to spatio-temporal and spectroscopic resolution originating from the image charge on the surface and from the profile of the exciting laser pulse. By contrasting the effect of varying surface properties (leading to expanding or pinned image charge), laser profiles (Gaussian, uniform, and elliptical), and aspect ratios (pancake- and cigar-like) under different extraction field strengths and numbers of generated electrons, we quantify the effect of these experimental parameters on macroscopic pulse properties such as emittance, brightness (4D and 6D), coherence length, and energy spread. Based on our results, we outline optimal conditions of pulse generation for ultrafast electron microscope systems that take into account constraints on the number of generated electrons and on the required time resolution.

Portman, J.; Zhang, H.; Makino, K.; Ruan, C. Y.; Berz, M.; Duxbury, P. M. [Physics and Astronomy Department, Michigan State University, East Lansing, Michigan 48824 (United States)

2014-11-07T23:59:59.000Z

64

Investigating high speed phenomena in laser plasma interactions using dilation x-ray imager (invited)  

SciTech Connect (OSTI)

The DIlation X-ray Imager (DIXI) is a new, high-speed x-ray framing camera at the National Ignition Facility (NIF) sensitive to x-rays in the range of ?2–17 keV. DIXI uses the pulse-dilation technique to achieve a temporal resolution of less than 10 ps, a ?10× improvement over conventional framing cameras currently employed on the NIF (?100 ps resolution), and otherwise only attainable with 1D streaked imaging. The pulse-dilation technique utilizes a voltage ramp to impart a velocity gradient on the signal-bearing electrons. The temporal response, spatial resolution, and x-ray sensitivity of DIXI are characterized with a short x-ray impulse generated using the COMET laser facility at Lawrence Livermore National Laboratory. At the NIF a pinhole array at 10 cm from target chamber center (tcc) projects images onto the photocathode situated outside the NIF chamber wall with a magnification of ?64×. DIXI will provide important capabilities for warm-dense-matter physics, high-energy-density science, and inertial confinement fusion, adding important capabilities to temporally resolve hot-spot formation, x-ray emission, fuel motion, and mix levels in the hot-spot at neutron yields of up to 10{sup 17}. We present characterization data as well as first results on electron-transport phenomena in buried-layer foil experiments.

Nagel, S. R., E-mail: nagel7@llnl.gov; Bell, P. M.; Bradley, D. K.; Ayers, M. J.; Piston, K.; Felker, B. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States); Hilsabeck, T. J.; Kilkenny, J. D.; Chung, T.; Sammuli, B. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Hares, J. D.; Dymoke-Bradshaw, A. K. L. [Kentech Instruments Ltd., Wallingford, Oxfordshire OX10 (United Kingdom)

2014-11-15T23:59:59.000Z

65

Desorption Dynamics, Internal Energies and Imaging of Organic Molecules from Surfaces with Laser Desorption and Vacuum Ultraviolet (VUV) Photoionization  

SciTech Connect (OSTI)

There is enormous interest in visualizing the chemical composition of organic material that comprises our world. A convenient method to obtain molecular information with high spatial resolution is imaging mass spectrometry. However, the internal energy deposited within molecules upon transfer to the gas phase from a surface can lead to increased fragmentation and to complications in analysis of mass spectra. Here it is shown that in laser desorption with postionization by tunable vacuum ultraviolet (VUV) radiation, the internal energy gained during laser desorption leads to minimal fragmentation of DNA bases. The internal temperature of laser-desorbed triacontane molecules approaches 670 K, whereas the internal temperature of thymine is 800 K. A synchrotron-based VUV postionization technique for determining translational temperatures reveals that biomolecules have translational temperatures in the range of 216-346 K. The observed low translational temperatures, as well as their decrease with increased desorption laser power is explained by collisional cooling. An example of imaging mass spectrometry on an organic polymer, using laser desorption VUV postionization shows 5 mu m feature details while using a 30 mu m laser spot size and 7 ns duration. Applications of laser desorption postionization to the analysis of cellulose, lignin and humic acids are briefly discussed.

Kostko, Oleg; Takahashi, Lynelle K.; Ahmed, Musahid

2011-04-05T23:59:59.000Z

66

The design and construction of a high-resolution velocity-map imaging apparatus for photoelectron spectroscopy studies of size-selected clusters  

SciTech Connect (OSTI)

A new velocity-map imaging apparatus equipped with a laser-vaporization supersonic cluster source and a time-of-flight mass spectrometer is described for high-resolution photoelectron spectroscopy studies of size-selected cluster anions. Vibrationally cold anion clusters are produced using a laser-vaporization supersonic cluster source, size-selected by a time-of-flight mass spectrometer, and then focused co-linearly into the interaction zone of the high-resolution velocity-map imaging (VMI) system. The multilens VMI system is optimized via systematic simulations and can reach a resolution of 1.2 cm{sup ?1} (FWHM) for near threshold electrons while maintaining photoelectron kinetic energy resolutions (?KE/KE) of ?0.53% for higher energy electrons. The new VMI lens has superior focusing power over a large energy range, yielding highly circular images with distortions no larger than 1.0025 between the long and short radii. The detailed design, simulation, construction, testing, and performance of the high-resolution VMI apparatus are presented.

León, Iker; Yang, Zheng; Liu, Hong-Tao; Wang, Lai-Sheng, E-mail: Lai-Sheng-Wang@brown.edu [Department of Chemistry, Brown University, Providence, Rhode Island 02912 (United States)

2014-08-15T23:59:59.000Z

67

The Potential for Bayesian Compressive Sensing to Significantly Reduce Electron Dose in High Resolution STEM Images  

SciTech Connect (OSTI)

The use of high resolution imaging methods in the scanning transmission electron microscope (STEM) is limited in many cases by the sensitivity of the sample to the beam and the onset of electron beam damage (for example in the study of organic systems, in tomography and during in-situ experiments). To demonstrate that alternative strategies for image acquisition can help alleviate this beam damage issue, here we apply compressive sensing via Bayesian dictionary learning to high resolution STEM images. These experiments successively reduce the number of pixels in the image (thereby reducing the overall dose while maintaining the high resolution information) and show promising results for reconstructing images from this reduced set of randomly collected measurements. We show that this approach is valid for both atomic resolution images and nanometer resolution studies, such as those that might be used in tomography datasets, by applying the method to images of strontium titanate and zeolites. As STEM images are acquired pixel by pixel while the beam is scanned over the surface of the sample, these post acquisition manipulations of the images can, in principle, be directly implemented as a low-dose acquisition method with no change in the electron optics or alignment of the microscope itself.

Stevens, Andrew J.; Yang, Hao; Carin, Lawrence; Arslan, Ilke; Browning, Nigel D.

2014-02-11T23:59:59.000Z

68

Decreasing range resolution of a SAR image to permit correction of motion measurement errors beyond the SAR range resolution  

SciTech Connect (OSTI)

Motion measurement errors that extend beyond the range resolution of a synthetic aperture radar (SAR) can be corrected by effectively decreasing the range resolution of the SAR in order to permit measurement of the error. Range profiles can be compared across the slow-time dimension of the input data in order to estimate the error. Once the error has been determined, appropriate frequency and phase correction can be applied to the uncompressed input data, after which range and azimuth compression can be performed to produce a desired SAR image.

Doerry, Armin W. (Albuquerque, NM); Heard, Freddie E. (Albuquerque, NM); Cordaro, J. Thomas (Albuquerque, NM)

2010-07-20T23:59:59.000Z

69

Holographic laser Doppler imaging of pulsatile blood flow  

E-Print Network [OSTI]

We report on wide-field imaging of pulsatile motion induced by blood flow using heterodyne holographic interferometry on the thumb of a healthy volunteer, in real-time. Optical Doppler images were measured with green laser light by a frequency-shifted Mach-Zehnder interferometer in off-axis configuration. The recorded optical signal was linked to local instantaneous out-of-plane motion of the skin at velocities of a few hundreds of microns per second, and compared to blood pulse monitored by plethysmoraphy during an occlusion-reperfusion experiment.

Bencteux, Jeffrey; Kostas, Thomas; Bayat, Sam; Atlan, Michael

2015-01-01T23:59:59.000Z

70

Femtosecond diffractive imaging with a soft-X-ray free-electron laser  

E-Print Network [OSTI]

LETTERS Femtosecond diffractive imaging with a soft-X-ray free-electron laser HENRY N. CHAPMAN1 of this principle using the FLASH soft-X-ray free-electron laser. An intense 25 fs, 4 Ã? 1013 W cm-2 pulse by one10 . X-ray free-electron lasers (FELs) are expected to permit diffractive imaging at high

Loss, Daniel

71

Perfusion-Based High-Resolution Functional Imaging in the Human Brain at 7 Tesla  

E-Print Network [OSTI]

Perfusion-Based High-Resolution Functional Imaging in the Human Brain at 7 Tesla Josef Pfeuffer and reperfusion, blood flow deficits in Alzheimer's disease, HIV-cognitive motor complex dementia, and epilepsy (5

72

Design of thick aperture for fine-resolution neutron penumbral imaging  

SciTech Connect (OSTI)

Compact sources of 14-MeV neutrons have been imaged with a penumbral-coded aperture at a two-point resolution of 80{mu}m. We desire to improve the penumbral-aperture microscope to obtain resolutions as fine as 10{mu}m. In penumbral-coded-aperture imaging, the resolution is ultimately limited by the sharpness of the aperture point-spread function. I present a design for a thick penumbral aperture that provides the desired sharpness over a field of view of 150{mu}m. The point-spread function of these apertures is sufficiently isoplanatic and distortion-free to allow linear reconstruction of complex source distributions. The designs is generally appropriate for similar imaging techniques, such as fine-resolution neutron or gamma-ray pinhole imaging. 5 refs., 5 figs.

Ress, D.

1989-10-19T23:59:59.000Z

73

High Resolution Backside Imaging and Thermography using a Numerical Aperture Increasing Lens  

E-Print Network [OSTI]

High Resolution Backside Imaging and Thermography using a Numerical Aperture Increasing Lens Shawn inspection alone, it is necessary to develop techniques, such as thermography, with the capability ­solid immersion lens microscopy and thermography. Standard non-contact optical resolution is limited

74

Mapping daily snow//ice shortwave broadband albedo from Moderate Resolution Imaging Spectroradiometer (MODIS): The improved  

E-Print Network [OSTI]

and global energy balances when snow coverage is variable. In the polar regions, the high surface albedo acts the Advanced Very High Resolution Radiometer (AVHRR) satellite data in polar regions [De Abreu et al., 1994 variable in surface energy balance calculations. The Moderate Resolution Imaging Spectroradiometer (MODIS

Liang, Shunlin

75

Range imaging: a new method for high-resolution topographic measurements in small-and medium-  

E-Print Network [OSTI]

Range imaging: a new method for high-resolution topographic measurements in small- and medium is a useful complement or alternative to existing methods for high-resolution measurements in small- to medium has led to a dramatic increase in terrain information and opened up new opportunities for hydro- logic

Kirchner, James W.

76

HIGH-RESOLUTION LAND/ICE IMAGING USING SEASAT SCATTEROMETER MEASUREMENTS  

E-Print Network [OSTI]

scatterometers which would permit the method to produce 1-2 km resolution over land and ice. The highHIGH-RESOLUTION LAND/ICE IMAGING USING SEASAT SCATTEROMETER MEASUREMENTS D. G. Long*, P. T. Whiting by the scatterometer,is expected to significantly enhance the utility of sca.tteroineter data in various land, ice

Long, David G.

77

High-resolution multi-heterodyne spectroscopy based on Fabry-Perot quantum cascade lasers  

SciTech Connect (OSTI)

In this Letter, we present a method of performing broadband mid-infrared spectroscopy with conventional, free-running, continuous wave Fabry-Perot quantum cascade lasers (FP-QCLs). The measurement method is based on multi-heterodyne down-conversion of optical signals. The sample transmission spectrum probed by one multi-mode FP-QCL is down-converted to the radio-frequency domain through an optical multi-heterodyne process using a second FP-QCL as the local oscillator. Both a broadband multi-mode spectral measurement as well as high-resolution (?15?MHz) spectroscopy of molecular absorption are demonstrated and show great potential for development of high performance FP-laser-based spectrometers for chemical sensing.

Wang, Yin; Wang, Wen; Wysocki, Gerard, E-mail: gwysocki@princeton.edu [Department of Electrical Engineering, Princeton University, Princeton, New Jersey 08540 (United States); Soskind, Michael G. [Department of Electrical Engineering, Princeton University, Princeton, New Jersey 08540 (United States); Department of Electrical Engineering, Rutgers University, New Brunswick, New Jersy 08901 (United States)

2014-01-20T23:59:59.000Z

78

A global forest canopy height map from the Moderate Resolution Imaging Spectroradiometer and the Geoscience  

E-Print Network [OSTI]

- radiometer and the Geoscience Laser Altimeter System, Geophys. Res. Lett., 37, L15401, doi:10.1029/2010GL, is sensitive throughout the range of biomass [Lefsky et al., 2005a, 2005b]. Each lidar waveform is a high spatial resolution record of the energy returned when a shortduration pulse of light is returned from

Lefsky, Michael

79

Supplementary Information Super-resolution imaging reveals eightfold symmetry of  

E-Print Network [OSTI]

around the nuclear pore complex and resolves the central channel with nanometer resolution Anna to M.S. (m.sauer@uni-wuerzburg.de). #12; 2 Figure S1. Alexa647 labeled gp210 protein in the nuclear bar 5 µm. #12; 3 Figure S2. Nuclear envelope resolved by two different microscopy methods. (a

Rieger, Bernd

80

High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography  

DOE Patents [OSTI]

This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

Olivier, Scot S. (Livermore, CA); Werner, John S. (Davis, CA); Zawadzki, Robert J. (Sacramento, CA); Laut, Sophie P. (Pasedena, CA); Jones, Steven M. (Livermore, CA)

2010-09-07T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Note: Spatial resolution of Fuji BAS-TR and BAS-SR imaging plates  

SciTech Connect (OSTI)

The spatial resolution of two types of imaging plates, Fuji BAS-TR and Fuji BAS-SR, has been measured using a knife-edge x-ray source of 8-keV Cu K{sub {alpha}} radiation. The values for the spatial resolution, defined as the distance between 10% and 90% levels of the edge spread function, are 94 {mu}m and 109 {mu}m, respectively. The resolution values are important for quantitative analysis of x-ray and particle imaging and spectroscopic diagnostics.

Fiksel, G.; Marshall, F. J.; Mileham, C.; Stoeckl, C. [Laboratory for Laser Energetics, University of Rochester, 250 East River Rd., Rochester, New York 14623-1299 (United States)

2012-08-15T23:59:59.000Z

82

Applications of Fourier Domain Mode Locked lasers for optical coherence tomography imaging  

E-Print Network [OSTI]

Optical coherence tomography (OCT) is a micrometer-resolution imaging technique that produces cross-sectional images of sample microstructure by measuring the amplitude and echo time delay of backscattered light. OCT imaging ...

Adler, Desmond Christopher, 1978-

2009-01-01T23:59:59.000Z

83

A high-resolution, four-band SAR testbed with real-time image formation  

SciTech Connect (OSTI)

This paper describes the Twin-Otter SAR Testbed developed at Sandia National Laboratories. This SAR is a flexible, adaptable testbed capable of operation on four frequency bands: Ka, Ku, X, and VHF/UHF bands. The SAR features real-time image formation at fine resolution in spotlight and stripmap modes. High-quality images are formed in real time using the overlapped subaperture (OSA) image-formation and phase gradient autofocus (PGA) algorithms.

Walker, B.; Sander, G.; Thompson, M.; Burns, B.; Fellerhoff, R.; Dubbert, D.

1996-03-01T23:59:59.000Z

84

Chandra High Resolution Camera Imaging of GRS 1758-258  

E-Print Network [OSTI]

We observed the "micro-quasar" GRS 1758-258 four times with Chandra. Two HRC-I observations were made in 2000 September-October spanning an intermediate-to-hard spectral transition (identified with RXTE). Another HRC-I and an ACIS/HETG observation were made in 2001 March following a hard-to-soft transition to a very low flux state. Based on the three HRC images and the HETG zero order image, the accurate position (J2000) of the X-ray source is RA = 18h 01m 12.39s, Dec = -25d 44m 36.1s (90% confidence radius = 0".45), consistent with the purported variable radio counterpart. All three HRC images are consistent with GRS 1758-258 being a point source, indicating that any bright jet is less than ~1 light-month in projected length, assuming a distance of 8.5 kpc.

W. A. Heindl; D. M. Smith

2002-08-19T23:59:59.000Z

85

A high-resolution imaging x-ray crystal spectrometer for high energy density plasmas  

SciTech Connect (OSTI)

Adapting a concept developed for magnetic confinement fusion experiments, an imaging crystal spectrometer has been designed and tested for HED plasmas. The instrument uses a spherically bent quartz [211] crystal with radius of curvature of 490.8 mm. The instrument was tested at the Titan laser at Lawrence Livermore National Laboratory by irradiating titanium slabs with laser intensities of 10{sup 19}–10{sup 20} W/cm{sup 2}. He-like and Li-like Ti lines were recorded, from which the spectrometer performance was evaluated. This spectrometer provides very high spectral resolving power (E/dE > 7000) while acquiring a one-dimensional image of the source.

Chen, Hui, E-mail: chen33@llnl.gov, E-mail: bitter@pppl.gov; Magee, E.; Nagel, S. R.; Park, J.; Schneider, M. B.; Stone, G.; Williams, G. J.; Beiersdorfer, P. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550-9234 (United States); Bitter, M., E-mail: chen33@llnl.gov, E-mail: bitter@pppl.gov; Hill, K. W. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Kerr, S. [Department of Applied Science, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada)

2014-11-15T23:59:59.000Z

86

Isotopic imaging via nuclear resonance fluorescence with laser-based Thomson radiation  

DOE Patents [OSTI]

The present invention utilizes novel laser-based, high-brightness, high-spatial-resolution, pencil-beam sources of spectrally pure hard x-ray and gamma-ray radiation to induce resonant scattering in specific nuclei, i.e., nuclear resonance fluorescence. By monitoring such fluorescence as a function of beam position, it is possible to image in either two dimensions or three dimensions, the position and concentration of individual isotopes in a specific material configuration. Such methods of the present invention material identification, spatial resolution of material location and ability to locate and identify materials shielded by other materials, such as, for example, behind a lead wall. The foundation of the present invention is the generation of quasimonochromatic high-energy x-ray (100's of keV) and gamma-ray (greater than about 1 MeV) radiation via the collision of intense laser pulses from relativistic electrons. Such a process as utilized herein, i.e., Thomson scattering or inverse-Compton scattering, produces beams having diameters from about 1 micron to about 100 microns of high-energy photons with a bandwidth of .DELTA.E/E of approximately 10E.sup.-3.

Barty, Christopher P. J. (Hayward, CA); Hartemann, Frederic V. (San Ramon, CA); McNabb, Dennis P. (Alameda, CA); Pruet, Jason A. (Brentwood, CA)

2009-07-21T23:59:59.000Z

87

Local Optical Spectroscopies for Subnanometer Spatial Resolution Chemical Imaging  

SciTech Connect (OSTI)

The evanescently coupled photon scanning tunneling microscopes (STMs) have special requirements in terms of stability and optical access. We have made substantial improvements to the stability, resolution, and noise floor of our custom-built visible-photon STM, and will translate these advances to our infrared instrument. Double vibration isolation of the STM base with a damping system achieved increased rigidity, giving high tunneling junction stability for long-duration and high-power illumination. Light frequency modulation with an optical chopper and phase-sensitive detection now enhance the signal-to-noise ratio of the tunneling junction during irradiation.

Weiss, Paul

2014-01-20T23:59:59.000Z

88

High-resolution adaptive optics scanning laser ophthalmoscope with multiple deformable mirrors  

DOE Patents [OSTI]

An adaptive optics scanning laser ophthalmoscopes is introduced to produce non-invasive views of the human retina. The use of dual deformable mirrors improved the dynamic range for correction of the wavefront aberrations compared with the use of the MEMS mirror alone, and improved the quality of the wavefront correction compared with the use of the bimorph mirror alone. The large-stroke bimorph deformable mirror improved the capability for axial sectioning with the confocal imaging system by providing an easier way to move the focus axially through different layers of the retina.

Chen, Diana C. (Fremont, CA); Olivier, Scot S. (Livermore, CA); Jones; Steven M. (Livermore, CA)

2010-02-23T23:59:59.000Z

89

High resolution x-ray and gamma ray imaging using diffraction lenses with mechanically bent crystals  

DOE Patents [OSTI]

A method for high spatial resolution imaging of a plurality of sources of x-ray and gamma-ray radiation is provided. High quality mechanically bent diffracting crystals of 0.1 mm radial width are used for focusing the radiation and directing the radiation to an array of detectors which is used for analyzing their addition to collect data as to the location of the source of radiation. A computer is used for converting the data to an image. The invention also provides for the use of a multi-component high resolution detector array and for narrow source and detector apertures.

Smither, Robert K. (Hinsdale, IL)

2008-12-23T23:59:59.000Z

90

High-Resolution 3 T MR Microscopy Imaging of Arterial Walls  

SciTech Connect (OSTI)

Purpose. To achieve a high spatial resolution in MR imaging that allows for clear visualization of anatomy and even histology and documentation of plaque morphology in in vitro samples from patients with advanced atherosclerosis. A further objective of our study was to evaluate whether T2-weighted high-resolution MR imaging can provide accurate classification of atherosclerotic plaque according to a modified American Heart Association classification. Methods. T2-weighted images of arteries were obtained in 13 in vitro specimens using a 3 T MR unit (Medspec 300 Avance/Bruker, Ettlingen, Germany) combined with a dedicated MR microscopy system. Measurement parameters were: T2-weighted sequences with TR 3.5 sec, TE 15-120 msec; field of view (FOV) 1.4 x 1.4; NEX 8; matrix 192; and slice thickness 600 {mu}m. MR measurements were compared with corresponding histologic sections. Results. We achieved excellent spatial and contrast resolution in all specimens. We found high agreement between MR images and histology with regard to the morphology and extent of intimal proliferations in all but 2 specimens. We could differentiate fibrous caps and calcifications from lipid plaque components based on differences in signal intensity in order to differentiate hard and soft atheromatous plaques. Hard plaques with predominantly intimal calcifications were found in 7 specimens, and soft plaques with a cholesterol/lipid content in 5 cases. In all specimens, hemorrhage or thrombus formation, and fibrotic and hyalinized tissue could be detected on both MR imaging and histopathology. Conclusion. High-resolution, high-field MR imaging of arterial walls demonstrates the morphologic features, volume, and extent of intimal proliferations with high spatial and contrast resolution in in vitro specimens and can differentiate hard and soft plaques.

Sailer, Johannes, E-mail: johannes.sailer@univie.ac.at; Rand, Thomas [University of Vienna, Department of Angiography and Interventional Radiology (Austria); Berg, Andreas [University of Vienna, Institute for Medical Physics (Austria); Sulzbacher, Irene [University of Vienna, Clinical Institute of Pathology (Austria); Peloschek, P. [University of Vienna, Department of Angiography and Interventional Radiology (Austria); Hoelzenbein, Thomas [University of Vienna, Department of Surgery (Austria); Lammer, Johannes [University of Vienna, Department of Angiography and Interventional Radiology (Austria)

2006-10-15T23:59:59.000Z

91

High spatial resolution X-ray and gamma ray imaging system using diffraction crystals  

DOE Patents [OSTI]

A method and a device for high spatial resolution imaging of a plurality of sources of x-ray and gamma-ray radiation are provided. The device comprises a plurality of arrays, with each array comprising a plurality of elements comprising a first collimator, a diffracting crystal, a second collimator, and a detector.

Smither, Robert K. (Hinsdale, IL)

2011-05-17T23:59:59.000Z

92

CLASSIFICATION OF BIOMEDICAL HIGH-RESOLUTION MICRO-CT IMAGES FOR DIRECT VOLUME RENDERING  

E-Print Network [OSTI]

CLASSIFICATION OF BIOMEDICAL HIGH-RESOLUTION MICRO-CT IMAGES FOR DIRECT VOLUME RENDERING Maite L,cerquide,davidm,anna}@maia.ub.es ABSTRACT This paper introduces a machine learning approach into the process of direct volume rendering that generates the classification func- tion within the optical property function used for rendering. Briefly

López-Sánchez, Maite

93

Imaging laser analysis of building materials - practical examples  

SciTech Connect (OSTI)

The Laser induced Breakdown Spectroscopy (LIBS) is supplement and extension of standard chemical methods and SEM- or Micro-RFA-applications for the evaluation of building materials. As a laboratory method LIBS is used to gain color coded images representing composition, distribution of characteristic ions and/or ingress characteristic of damaging substances. To create a depth profile of element concentration a core has to be taken and split along the core axis. LIBS was proven to be able to detect all important elements in concrete, e. g. Chlorine, Sodium or Sulfur, which are responsible for certain degradation mechanisms and also light elements like lithium or hydrogen. Practical examples are given and a mobile system for on-site measurements is presented.

Wilsch, G.; Schaurich, D.; Wiggenhauser, H. [BAM, Federal Institute for Materials Research and Testing, Berlin (Germany)

2011-06-23T23:59:59.000Z

94

Single molecule imaging with longer x-ray laser pulses  

E-Print Network [OSTI]

In serial femtosecond crystallography, x-ray laser pulses do not need to outrun all radiation damage processes because Bragg diffraction exceeds the damage-induced background scattering for longer pulses ($\\sim$ 50--100 fs). This is due to a "self-gating pulse" effect whereby damage terminates Bragg diffraction prior to the pulse completing its passage through the sample, as if that diffraction were produced by a shorter pulse of equal fluence. We show here that a similar gating effect applies to single molecule diffraction with respect to spatially uncorrelated damage processes like ionization and ion diffusion. The effect is clearly seen in calculations of the diffraction contrast, by calculating the diffraction of average structure separately to the diffraction from statistical fluctuations of the structure due to damage ("damage noise"). Our results suggest that sub-nanometer single molecule imaging with longer pulses, like those produced at currently operating facilities, should not yet be ruled out. The...

Martin, Andrew V; Caleman, Carl; Quiney, Harry M

2015-01-01T23:59:59.000Z

95

The effect of spatial micro-CT image resolution and surface complexity on the morphological 3D analysis of open porous structures  

SciTech Connect (OSTI)

In material science microfocus X-ray computed tomography (micro-CT) is one of the most popular non-destructive techniques to visualise and quantify the internal structure of materials in 3D. Despite constant system improvements, state-of-the-art micro-CT images can still hold several artefacts typical for X-ray CT imaging that hinder further image-based processing, structural and quantitative analysis. For example spatial resolution is crucial for an appropriate characterisation as the voxel size essentially influences the partial volume effect. However, defining the adequate image resolution is not a trivial aspect and understanding the correlation between scan parameters like voxel size and the structural properties is crucial for comprehensive material characterisation using micro-CT. Therefore, the objective of this study was to evaluate the influence of the spatial image resolution on the micro-CT based morphological analysis of three-dimensional (3D) open porous structures with a high surface complexity. In particular the correlation between the local surface properties and the accuracy of the micro-CT-based macro-morphology of 3D open porous Ti6Al4V structures produced by selective laser melting (SLM) was targeted and revealed for rough surfaces a strong dependence of the resulting structure characteristics on the scan resolution. Reducing the surface complexity by chemical etching decreased the sensitivity of the overall morphological analysis to the spatial image resolution and increased the detection limit. This study showed that scan settings and image processing parameters need to be customized to the material properties, morphological parameters under investigation and the desired final characteristics (in relation to the intended functional use). Customization of the scan resolution can increase the reliability of the micro-CT based analysis and at the same time reduce its operating costs. - Highlights: • We examine influence of the image resolution on ?CT-based morphological analysis. • Surface properties influence accuracy of ?CT-based morphology of porous structures. • Total porosity was the least sensitive to surface complexity and scan voxel size. • The beam thickness analysis was overestimated by the surface roughness. • Voxel size customization can significantly reduce a cost of the ?CT-based analysis.

Pyka, Grzegorz, E-mail: gregory.pyka@mtm.kuleuven.be [Department of Metallurgy and Materials Engineering, KU Leuven, Kasteelpark Arenberg 44 – PB2450, B-3001 Leuven (Belgium); Kerckhofs, Greet [Department of Metallurgy and Materials Engineering, KU Leuven, Kasteelpark Arenberg 44 – PB2450, B-3001 Leuven (Belgium); Biomechanics Research Unit, Université de Liege, Chemin des Chevreuils 1 - BAT 52/3, B-4000 Liège (Belgium); Schrooten, Jan; Wevers, Martine [Department of Metallurgy and Materials Engineering, KU Leuven, Kasteelpark Arenberg 44 – PB2450, B-3001 Leuven (Belgium)

2014-01-15T23:59:59.000Z

96

Laser desorption/ionization mass spectrometry for direct profiling and imaging of small molecules from raw biological materials  

SciTech Connect (OSTI)

Matrix-assisted laser desorption/ionization(MALDI) mass spectrometry(MS) has been widely used for analysis of biological molecules, especially macromolecules such as proteins. However, MALDI MS has a problem in small molecule (less than 1 kDa) analysis because of the signal saturation by organic matrixes in the low mass region. In imaging MS (IMS), inhomogeneous surface formation due to the co-crystallization process by organic MALDI matrixes limits the spatial resolution of the mass spectral image. Therefore, to make laser desorption/ionization (LDI) MS more suitable for mass spectral profiling and imaging of small molecules directly from raw biological tissues, LDI MS protocols with various alternative assisting materials were developed and applied to many biological systems of interest. Colloidal graphite was used as a matrix for IMS of small molecules for the first time and methodologies for analyses of small metabolites in rat brain tissues, fruits, and plant tissues were developed. With rat brain tissues, the signal enhancement for cerebroside species by colloidal graphite was observed and images of cerebrosides were successfully generated by IMS. In addition, separation of isobaric lipid ions was performed by imaging tandem MS. Directly from Arabidopsis flowers, flavonoids were successfully profiled and heterogeneous distribution of flavonoids in petals was observed for the first time by graphite-assisted LDI(GALDI) IMS.

Cha, Sangwon

2008-05-15T23:59:59.000Z

97

Retrieval of Cloud Phase and Crystal Habit from Multiangle Imaging Spectroradiometer (MISR) and Moderate Resolution Imaging Spectroradiometer (MODIS) Data  

SciTech Connect (OSTI)

A method of retrieving cloud phase and the dominant ice crystal habit from radiances measured by the Multi-angle Imaging Spectro-Radiometer (MISR) and the Moderate Resolution Imaging Spectroradiometer (MODIS) has been developed. The retrieval method takes advantage of the differences in the phase function of various particle shapes as a function of scattering angle. Three case studies are presented which illustrate the retrieval method. A comparison with semi-coincident in situ observations for one case study indicates that the retrieved crystal habits are consistent with the observations.

McFarlane, Sally A.; Marchand, Roger T.; Ackerman, Thomas P.

2005-07-22T23:59:59.000Z

98

Animals In Synchrotrons: Overcoming Challenges For High-Resolution, Live, Small-Animal Imaging  

SciTech Connect (OSTI)

Physiological studies in small animals can be complicated, but the complexity is increased dramatically when performing live-animal synchrotron X-ray imaging studies. Our group has extensive experience in high-resolution live-animal imaging at the Japanese SPring-8 synchrotron, primarily examining airways in two-dimensions. These experiments normally image an area of 1.8 mmx1.2 mm at a pixel resolution of 0.45 {mu}m and are performed with live, intact, anaesthetized mice.There are unique challenges in this experimental setting. Importantly, experiments must be performed in an isolated imaging hutch not specifically designed for small-animal imaging. This requires equipment adapted to remotely monitor animals, maintain their anesthesia, and deliver test substances while collecting images. The horizontal synchrotron X-ray beam has a fixed location and orientation that limits experimental flexibility. The extremely high resolution makes locating anatomical regions-of-interest slow and can result in a high radiation dose, and at this level of magnification small animal movements produce motion-artifacts that can render acquired images unusable. Here we describe our experimental techniques and how we have overcome several challenges involved in performing live mouse synchrotron imaging.Experiments have tested different mouse strains, with hairless strains minimizing overlying skin and hair artifacts. Different anesthetics have also be trialed due to the limited choices available at SPring-8. Tracheal-intubation methods have been refined and controlled-ventilation is now possible using a specialized small-animal ventilator. With appropriate animal restraint and respiratory-gating, motion-artifacts have been minimized. The animal orientation (supine vs. head-high) also appears to affect animal physiology, and can alter image quality. Our techniques and image quality at SPring-8 have dramatically improved and in the near future we plan to translate this experience to the Imaging and Medical Beamline at the Australian Synchrotron.Overcoming these challenges has permitted increasingly sophisticated imaging of animals with synchrotron X-rays, and we expect a bright future for these techniques.

Donnelley, Martin [Respiratory and Sleep Medicine, Women's and Children's Hospital, Adelaide, South Australia (Australia); Parsons, David [Respiratory and Sleep Medicine, Women's and Children's Hospital, Adelaide, South Australia (Australia); Women's and Children's Health Research Institute, Adelaide, South Australia (Australia); Department of Paediatrics and Reproductive Health, University of Adelaide, South Australia (Australia); Department of Paediatircs Centre for Stem Cell Research, University of Adelaide, South Australia (Australia); Morgan, Kaye [School of Physics, Monash University, Melbourne, Victoria (Australia); Siu, Karen [School of Physics, Monash University, Melbourne, Victoria (Australia); Monash Centre for Synchrotron Science, Monash University, Melbourne, Victoria (Australia)

2010-07-23T23:59:59.000Z

99

High-resolution chemical imaging of gold nanoparticles using hard x-ray ptychography  

SciTech Connect (OSTI)

We combine resonant scattering with (ptychographic) scanning coherent diffraction microscopy to determine the chemical state of gold nanoparticles with high spatial resolution. Ptychographic images of the sample are recorded for a series of energies around the gold L{sub 3} absorption edge. From these data, chemical information in the form of absorption and resonant scattering spectra is reconstructed at each location in the sample. For gold nanoparticles of about 100 nm diameter, a spatial resolution of about 20-30 nm is obtained. In the future, this microscopy approach will open the way to operando studies of heterogeneous catalysts on the nanometer scale.

Hoppe, R.; Patommel, J.; Schroer, C. G. [Institute of Structural Physics, Technische Universitaet Dresden, D-01062 Dresden (Germany)] [Institute of Structural Physics, Technische Universitaet Dresden, D-01062 Dresden (Germany); Reinhardt, J. [Institute of Structural Physics, Technische Universitaet Dresden, D-01062 Dresden (Germany) [Institute of Structural Physics, Technische Universitaet Dresden, D-01062 Dresden (Germany); Deutsches Elektronen-Synchrotron DESY, D-22607 Hamburg (Germany)] [Germany; Hofmann, G.; Grunwaldt, J.-D. [Institute for Chemical Technology and Polymer Chemistry, Karlsruhe Institute of Technology, D-76131 Karlsruhe (Germany)] [Institute for Chemical Technology and Polymer Chemistry, Karlsruhe Institute of Technology, D-76131 Karlsruhe (Germany); Damsgaard, C. D. [Center for Electron Nanoscopy and Department of Physics, Technical University of Denmark, DK-2800 Lyngby (Denmark)] [Center for Electron Nanoscopy and Department of Physics, Technical University of Denmark, DK-2800 Lyngby (Denmark); Wellenreuther, G.; Falkenberg, G. [Deutsches Elektronen-Synchrotron DESY, D-22607 Hamburg (Germany)] [Deutsches Elektronen-Synchrotron DESY, D-22607 Hamburg (Germany)

2013-05-20T23:59:59.000Z

100

High-throughput imaging of heterogeneous cell organelles with an X-ray laser  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Preprocessed detector images that were used for the paper "High-throughput imaging of heterogeneous cell organelles with an X-ray laser". The CXI file contains the entire recorded data - including both hits and blanks. It also includes down-sampled images and LCLS machine parameters. Additionally, the Cheetah configuration file is attached that was used to create the pre-processed data.

Hantke, Max, F.

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Development of high-spatial and high-mass resolution mass spectrometric imaging (MSI) and its application to the study of small metabolites and endogenous molecules of plants  

SciTech Connect (OSTI)

High-spatial and high-mass resolution laser desorption ionization (LDI) mass spectrometric (MS) imaging technology was developed for the attainment of MS images of higher quality containing more information on the relevant cellular and molecular biology in unprecedented depth. The distribution of plant metabolites is asymmetric throughout the cells and tissues, and therefore the increase in the spatial resolution was pursued to reveal the localization of plant metabolites at the cellular level by MS imaging. For achieving high-spatial resolution, the laser beam size was reduced by utilizing an optical fiber with small core diameter (25 ?m) in a vacuum matrix-assisted laser desorption ionization-linear ion trap (vMALDI-LTQ) mass spectrometer. Matrix application was greatly improved using oscillating capillary nebulizer. As a result, single cell level spatial resolution of ~ 12 ?m was achieved. MS imaging at this high spatial resolution was directly applied to a whole Arabidopsis flower and the substructures of an anther and single pollen grains at the stigma and anther were successfully visualized. MS imaging of high spatial resolution was also demonstrated to the secondary roots of Arabidopsis thaliana and a high degree of localization of detected metabolites was successfully unveiled. This was the first MS imaging on the root for molecular species. MS imaging with high mass resolution was also achieved by utilizing the LTQ-Orbitrap mass spectrometer for the direct identification of the surface metabolites on the Arabidopsis stem and root and differentiation of isobaric ions having the same nominal mass with no need of tandem mass spectrometry (MS/MS). MS imaging at high-spatial and high-mass resolution was also applied to cer1 mutant of the model system Arabidopsis thaliana to demonstrate its usefulness in biological studies and reveal associated metabolite changes in terms of spatial distribution and/or abundances compared to those of wild-type. The spatial distribution of targeted metabolites, mainly waxes and flavonoids, was systematically explored on various organs, including flowers, leaves, stems, and roots at high spatial resolution of ~ 12-50 ?m and the changes in the abundance level of these metabolites were monitored on the cer1 mutant with respect to the wild-type. This study revealed the metabolic biology of CER1 gene on each individual organ level with very detailed high spatial resolution. The separate MS images of isobaric metabolites, i.e. C29 alkane vs. C28 aldehyde could be constructed on both genotypes from MS imaging at high mass resolution. This allows tracking of abundance changes for those compounds along with the genetic mutation, which is not achievable with low mass resolution mass spectrometry. This study supported previous hypothesis of molecular function of CER1 gene as aldehyde decarbonylase, especially by displaying hyper accumulation of aldehydes and C30 fatty acid and decrease in abundance of alkanes and ketones in several plant organs of cer1 mutant. The scope of analytes was further directed toward internal cell metabolites from the surface metabolites of the plant. MS profiling and imaging of internal cell metabolites were performed on the vibratome section of Arabidopsis leaf. Vibratome sectioning of the leaf was first conducted to remove the surface cuticle layer and it was followed by enzymatic treatment of the section to induce the digestion of primary cell walls, middle lamella, and expose the internal cells underneath to the surface for detection with the laser by LDI-MS. The subsequent MS imaging onto the enzymatically treated vibratome section allowed us to map the distribution of the metabolites in the internal cell layers, linolenic acid (C18:3 FA) and linoleic acid (C18:2 FA). The development of an assay for relative quantification of analytes at the single subcellular/organelle level by LDI-MS imaging was attempted and both plausibility and significant obstacles were seen. As a test system, native plant organelle, chloroplasts isolated from the spinach leaves were used

Jun, Ji Hyun

2011-11-30T23:59:59.000Z

102

Near infrared spectral imaging of explosives using a tunable laser source  

SciTech Connect (OSTI)

Diffuse reflectance near infrared hyperspectral imaging is an important analytical tool for a wide variety of industries, including agriculture consumer products, chemical and pharmaceutical development and production. Using this technique as a method for the standoff detection of explosive particles is presented and discussed. The detection of the particles is based on the diffuse reflectance of light from the particle in the near infrared wavelength range where CH, NH, OH vibrational overtones and combination bands are prominent. The imaging system is a NIR focal plane array camera with a tunable OPO/laser system as the illumination source. The OPO is programmed to scan over a wide spectral range in the NIR and the camera is synchronized to record the light reflected from the target for each wavelength. The spectral resolution of this system is significantly higher than that of hyperspectral systems that incorporate filters or dispersive elements. The data acquisition is very fast and the entire hyperspectral cube can be collected in seconds. A comparison of data collected with the OPO system to data obtained with a broadband light source with LCTF filters is presented.

Klunder, G L; Margalith, E; Nguyen, L K

2010-03-26T23:59:59.000Z

103

An attempt to study LiH and Li{sub 2} molecules by high resolution pulsed laser spectroscopy  

SciTech Connect (OSTI)

As we start a program to study alkali hydrides and dimers, we have developed a two-step photoionisation experiment on Li{sub 2} molecules based on the use of an atomic beam and two pulsed dye lasers. The first resonant step which excites the A {sup 1}{sigma}{sub u}{sup +}-X {sup 1}{sigma}{sub g}{sup +}Li{sub 2} dimer systems is a home-made cw-seeded DCM dye laser with a laser linewidth of 55 MHz (FWHM) and near the Fourier transform limit. The second step is a larger width fixed frequency UV laser which allows the photoionisation of the selectively excited molecules. The three {sup 6}Li{sub 2}, {sup 6}Li {sup 7}Li and {sup 7}Li{sub 2} spectra are recorded simultaneously by the use of a doubly-accelerating time-of-flight ion analyser. Comparison between recorded and calculated absorption spectra using Dunham parameters found in the literature is satisfactory. To develop similar pulsed high-resolution investigations in LiH, we have characterized our molecular beam by using the laser induced fluorescence (LIF) technique with a cw blue dye laser. Two Franck-Condon LiH Doppler-free resonances have been observed.

Bouloufa, Nadia; Cabaret, Louis; Cacciani, Patrice; Camus, Pierre; Pitcheev, Boris; Vetter, Raymond [Laboratoire Aime Cotton, CNRS II, Bat 505, Campus d'Orsay, 91405 Orsay Cedex (France)

1998-12-16T23:59:59.000Z

104

A high spatial resolution Stokes polarimeter for motional Stark effect imaging  

SciTech Connect (OSTI)

We describe an enhanced temporally switched interfero-polarimeter that has been successfully deployed for high spatial resolution motional Stark effect imaging on the KSTAR superconducting tokamak. The system utilizes dual switching ferroelectric liquid crystal waveplates to image the full Stokes vector of elliptically polarized and Doppler-shifted Stark-Zeeman Balmer-alpha emission from high energy neutral beams injected into the magnetized plasma. We describe the optical system and compare its performance against a Mueller matrix model that takes account of non-ideal performance of the switching ferro-electric liquid crystal waveplates and other polarizing components.

Thorman, Alex; Michael, Clive; Howard, John [Plasma Research Laboratory, Research School of Physics and Engineering, Australian National University, Canberra ACT 0200 (Australia)

2013-06-15T23:59:59.000Z

105

High resolution neutron imaging of water in the polymer electrolyte fuel cell membrane  

SciTech Connect (OSTI)

Water transport in the ionomeric membrane, typically Nafion{reg_sign}, has profound influence on the performance of the polymer electrolyte fuel cell, in terms of internal resistance and overall water balance. In this work, high resolution neutron imaging of the Nafion{reg_sign} membrane is presented in order to measure water content and through-plane gradients in situ under disparate temperature and humidification conditions.

Mukherjee, Partha P [Los Alamos National Laboratory; Makundan, Rangachary [Los Alamos National Laboratory; Spendelow, Jacob S [Los Alamos National Laboratory; Borup, Rodney L [Los Alamos National Laboratory; Hussey, D S [NIST; Jacobson, D L [NIST; Arif, M [NIST

2009-01-01T23:59:59.000Z

106

Time-resolved imaging of material response during laser-induced bulk damage in SiO2  

SciTech Connect (OSTI)

We report on time resolved imaging of the dynamic events taking place during laser-induced damage in the bulk of fused silica samples with nanosecond temporal resolution and one micron spatial resolution. These events include: shock/pressure wave formation and propagation, transient absorption, crack propagation and formation of residual stress fields. The work has been performed using a time-resolved microscope system that utilizes a probe pulse to acquire images at delay times covering the entire timeline of a damage event. Image information is enhanced using polarized illumination and simultaneously recording the two orthogonal polarization image components. For the case of fused silica, an electronic excitation is first observed accompanied by the onset of a pressure wave generation and propagation. Cracks are seen to form early in the process and reach their final size at about 25 ns into the damage event. In addition, changes that in part are attributed to transient absorption in the modified material are observed for delays up to about 200 microseconds.

Demos, S G; Negres, R A

2008-10-24T23:59:59.000Z

107

High Spatial Resolution Fast-Neutron Imaging Detectors for Pulsed Fast-Neutron Transmission Spectroscopy  

E-Print Network [OSTI]

Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified camera systems (ICCD). This detector is designed for energy-selective neutron radiography with nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. Utilizing the Time-of-Flight (TOF) method, such a detector is capable of simultaneously capturing several images, each at a different neutron energy (TOF). In addition, a gamma-ray image can also be simultaneously registered, allowing combined neutron/gamma inspection of objects. This permits combining the sensitivity of the fast-neutron resonance method to low-Z elements with that of gamma radiography to high-Z materials.

Mor, I; Bar, D; Feldman, G; Goldberg, M B; Katz, D; Sayag, E; Shmueli, I; Cohen, Y; Tal, A; Vagish, Z; Bromberger, B; Dangendorf, V; Mugai, D; Tittelmeier, K; Weierganz, M

2009-01-01T23:59:59.000Z

108

A convenient alignment approach for x-ray imaging experiments based on laser positioning devices  

SciTech Connect (OSTI)

This study presents a two-laser alignment approach for facilitating the precise alignment of various imaging and measuring components with respect to the x-ray beam. The first laser constantly pointed to the output window of the source, in a direction parallel to the path along which the components are placed. The second laser beam, originating from the opposite direction, was calibrated to coincide with the first laser beam. Thus, a visible indicator of the direction of the incident x-ray beam was established, and the various components could then be aligned conveniently and accurately with its help.

Zhang Da; Donovan, Molly; Wu Xizeng; Liu Hong [Center for Bioengineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019 (United States); Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama 35233 (United States); Center for Bioengineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019 (United States)

2008-11-15T23:59:59.000Z

109

Pump-probe imaging of laser-induced periodic surface structures after ultrafast irradiation of Si  

SciTech Connect (OSTI)

Ultrafast pump-probe microscopy has been used to investigate laser-induced periodic surface structure (LIPSS) formation on polished Si surfaces. A crater forms on the surface after irradiation by a 150 fs laser pulse, and a second, subsequent pulse forms LIPSS within the crater. Sequentially delayed images show that LIPSS with a periodicity slightly less than the fundamental laser wavelength of 780 nm appear on Si surfaces ?50 ps after arrival of the second pump laser pulse, well after the onset of melting. LIPSS are observed on the same timescale as material removal, suggesting that their formation involves material ejection.

Murphy, Ryan D. [Applied Physics Program, University of Michigan, Ann Arbor, Michigan 48109 (United States)] [Applied Physics Program, University of Michigan, Ann Arbor, Michigan 48109 (United States); Torralva, Ben [Department of Atmospheric, Oceanic and Space Sciences, University of Michigan, Ann Arbor, Michigan 48109 (United States)] [Department of Atmospheric, Oceanic and Space Sciences, University of Michigan, Ann Arbor, Michigan 48109 (United States); Adams, David P. [Sandia National Laboratories, Albuquerque, New Mexico 87123 (United States)] [Sandia National Laboratories, Albuquerque, New Mexico 87123 (United States); Yalisove, Steven M. [Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan 48109 (United States)] [Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan 48109 (United States)

2013-09-30T23:59:59.000Z

110

Extended data analysis strategies for high resolution imaging MS: New methods to deal with extremely large image hyperspectral datasets  

E-Print Network [OSTI]

The large size of the hyperspectral datasets that are produced with modern mass spectrometric imaging techniques makes it difficult to analyze the results. Unsupervised statistical techniques are needed to extract relevant information from these datasets and reduce the data into a surveyable overview. Multivariate statistics are commonly used for this purpose. Computational power and computer memory limit the resolution at which the datasets can be analyzed with these techniques. We introduce the use of a data format capable of efficiently storing sparse datasets for multivariate analysis. This format is more memory-efficient and therefore it increases the possible resolution together with a decrease of computation time. Three multivariate techniques are compared for both sparse-type data and non-sparse data acquired in two different imaging ToF-SIMS experiments and one LDI-ToF imaging experiment. There is no significant qualitative difference in the use of different data formats for the same multivariate algorithms. All evaluated multivariate techniques could be applied on both SIMS and the LDI imaging datasets. Principal component analysis is shown to be the fastest choice; however a small increase of computation time using a VARIMAX optimization increases the decomposition quality significantly. PARAFAC analysis is shown to be very effective in separating different chemical components but the calculations take a significant amount of time, limiting its use as a routine technique. An effective visualization of the results of the multivariate analysis is as important for the analyst as the computational issues. For this reason, a new technique for visualization is presented, combining both spectral loadings and spatial

Leendert A. Klerk A; Er Broersen B; Ian W. Fletcher C

2006-01-01T23:59:59.000Z

111

Single mimivirus particles intercepted and imaged with an X-ray laser (CXIDB ID 1)  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

These are the files used to reconstruct the images in the paper "Single Mimivirus particles intercepted and imaged with an X-ray laser". Besides the diffracted intensities, the Hawk configuration files used for the reconstructions are also provided. The files from CXIDB ID 1 are the pattern and configuration files for the pattern showed in Figure 2a in the paper.

Seibert, M. Marvin; Ekeberg, Tomas; Maia, Filipe R.N.C.

112

Single mimivirus particles intercepted and imaged with an X-ray laser (CXIDB ID 2)  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

These are the files used to reconstruct the images in the paper "Single Mimivirus particles intercepted and imaged with an X-ray laser". Besides the diffracted intensities, the Hawk configuration files used for the reconstructions are also provided. The files from CXIDB ID 2 are the pattern and configuration files for the pattern showed in Figure 2b in the paper.

Seibert, M. Marvin; Ekeberg, Tomas

113

Design of a scanning Josephson junction microscope for submicron-resolution magnetic imaging  

SciTech Connect (OSTI)

We describe a magnetic field scanning instrument designed to extend the spatial resolution of scanning superconducting quantum interference device microscopy into the submicron regime. This instrument, the scanning Josephson junction microscope, scans a single Josephson junction across the surface of a sample, detecting the local magnetic field by the modulation of the junction critical current. By using a submicron junction and a scanning tunneling microscope feedback system to maintain close proximity to the surface, magnetic field sensitivity of 10 {mu}G with a spatial resolution of 0.3 {mu}m should be attainable, opening up new opportunities for imaging vortex configurations and core structure in superconductors and magnetic domains in magnetic materials. {copyright} {ital 1999 American Institute of Physics.}

Plourde, B.L.; Van Harlingen, D.J. [Department of Physics, Science and Technology Center for Superconductivity, and Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States)] [Department of Physics, Science and Technology Center for Superconductivity, and Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States)

1999-11-01T23:59:59.000Z

114

Design of a subnanometer resolution beam position monitor for dielectric laser accelerators  

E-Print Network [OSTI]

of the first laser-powered particle accel- erators "on a chip" [1,2]. These devices are specifically designed present a new concept for a beam position monitor with the unique ability to map particle beam position, this device is ideal for future x-ray sources and laser-driven particle accelerators "on a chip." © 2012

Byer, Robert L.

115

High-resolution single photon planar and spect imaging of brain and neck employing a system of two co-registered opposed gamma imaging heads  

DOE Patents [OSTI]

A compact, mobile, dedicated SPECT brain imager that can be easily moved to the patient to provide in-situ imaging, especially when the patient cannot be moved to the Nuclear Medicine imaging center. As a result of the widespread availability of single photon labeled biomarkers, the SPECT brain imager can be used in many locations, including remote locations away from medical centers. The SPECT imager improves the detection of gamma emission from the patient's head and neck area with a large field of view. Two identical lightweight gamma imaging detector heads are mounted to a rotating gantry and precisely mechanically co-registered to each other at 180 degrees. A unique imaging algorithm combines the co-registered images from the detector heads and provides several SPECT tomographic reconstructions of the imaged object thereby improving the diagnostic quality especially in the case of imaging requiring higher spatial resolution and sensitivity at the same time.

Majewski, Stanislaw (Yorktown, VA); Proffitt, James (Newport News, VA)

2011-12-06T23:59:59.000Z

116

Compact low resolution spectrograph, an imaging and long slit spectrograph for robotic telescopes  

SciTech Connect (OSTI)

The COmpact LOw REsolution Spectrograph (COLORES) is a compact and lightweight (13 kg) f/8 imaging spectrograph designed for robotic telescopes, now installed and operating on the TELMA, a rapid-slewing 60 cm telescope of the BOOTES-2 observatory in Málaga (Spain). COLORES is a multi-mode instrument that enables the observer to seamlessly switch between low-dispersion spectroscopy and direct imaging modes during an observation. In this paper, we describe the instrument and its development, from the initial scientific requirements through the optical design process to final configuration with theoretical performance calculations. The mechanical and electronic design is described, methods of calibration are discussed and early laboratory and scientific results are shown.

Rabaza, O., E-mail: ovidio@ugr.es [Department of Civil Engineering, University of Granada, Severo Ochoa Str. s/n, 18071 Granada (Spain); Institute of Astrophysics of Andalucía (CSIC), Glorieta de la Astronomía s/n, 18008 Granada (Spain); Jelinek, M.; Cunniffe, R.; Ruedas-Sánchez, J. [Institute of Astrophysics of Andalucía (CSIC), Glorieta de la Astronomía s/n, 18008 Granada (Spain)] [Institute of Astrophysics of Andalucía (CSIC), Glorieta de la Astronomía s/n, 18008 Granada (Spain); Castro-Tirado, A. J. [Institute of Astrophysics of Andalucía (CSIC), Glorieta de la Astronomía s/n, 18008 Granada (Spain) [Institute of Astrophysics of Andalucía (CSIC), Glorieta de la Astronomía s/n, 18008 Granada (Spain); Department of Systems and Automatic Engineering, University of Málaga, 29071 Málaga (Spain); Zeman, J. [Astronomical Institute of the Academic of Sciences, Fricova 298, 25165 Ondrejov (Czech Republic)] [Astronomical Institute of the Academic of Sciences, Fricova 298, 25165 Ondrejov (Czech Republic); Hudec, R. [Astronomical Institute of the Academic of Sciences, Fricova 298, 25165 Ondrejov (Czech Republic) [Astronomical Institute of the Academic of Sciences, Fricova 298, 25165 Ondrejov (Czech Republic); Faculty of Electrical Engineering, Czech Technical University, Technicka 2, Praha 6 (Czech Republic); Sabau-Graziati, L. [National Institute of Aerospace Technology, Carretera de Ajalvir, 28850 Madrid (Spain)] [National Institute of Aerospace Technology, Carretera de Ajalvir, 28850 Madrid (Spain)

2013-11-15T23:59:59.000Z

117

High-resolution heterodyne spectroscopy using a tunable quantum cascade laser around 3.5 THz  

E-Print Network [OSTI]

A frequency tunable terahertz heterodynespectrometer, based on a third-order distributed feedback quantum cascade laser as a local oscillator, has been demonstrated by measuring molecular spectral lines of methanol ...

Ren, Y.

118

A Curved Image-Plate Detector System for High-Resolution Synchrotron X-ray Diffraction  

SciTech Connect (OSTI)

The developed curved image plate (CIP) is a one-dimensional detector which simultaneously records high-resolution X-ray diffraction (XRD) patterns over a 38.7 2{theta} range. In addition, an on-site reader enables rapid extraction, transfer and storage of X-ray intensity information in {le}30 s, and further qualifies this detector to study kinetic processes in materials science. The CIP detector can detect and store X-ray intensity information linearly proportional to the incident photon flux over a dynamical range of about five orders of magnitude. The linearity and uniformity of the CIP detector response is not compromised in the unsaturated regions of the image plate, regardless of saturation in another region. The speed of XRD data acquisition together with excellent resolution afforded by the CIP detector is unique and opens up wide possibilities in materials research accessible through X-ray diffraction. This article presents details of the basic features, operation and performance of the CIP detector along with some examples of applications, including high-temperature XRD.

Sarin, P.; Haggerty, R; Yoon, W; Knapp, M; Berghaeuser, A; Zschack, P; Karapetrova, E; Yang, N; Kriven, W

2009-01-01T23:59:59.000Z

119

2D and 3D imaging resolution trade-offs in quantifying pore throats for prediction of permeability  

SciTech Connect (OSTI)

Although the impact of subsurface geochemical reactions on porosity is relatively well understood, changes in permeability remain difficult to estimate. In this work, pore-network modeling was used to predict permeability based on pore- and pore-throat size distributions determined from analysis of 2D scanning electron microscopy (SEM) images of thin sections and 3D X-ray computed microtomography (CMT) data. The analyzed specimens were a Viking sandstone sample from the Alberta sedimentary basin and an experimental column of reacted Hanford sediments. For the column, a decrease in permeability due to mineral precipitation was estimated, but the permeability estimates were dependent on imaging technique and resolution. X-ray CT imaging has the advantage of reconstructing a 3D pore network while 2D SEM imaging can easily analyze sub-grain and intragranular variations in mineralogy. Pore network models informed by analyses of 2D and 3D images at comparable resolutions produced permeability esti- mates with relatively good agreement. Large discrepancies in predicted permeabilities resulted from small variations in image resolution. Images with resolutions 0.4 to 4 lm predicted permeabilities differ- ing by orders of magnitude. While lower-resolution scans can analyze larger specimens, small pore throats may be missed due to resolution limitations, which in turn overestimates permeability in a pore-network model in which pore-to-pore conductances are statistically assigned. Conversely, high-res- olution scans are capable of capturing small pore throats, but if they are not actually flow-conducting predicted permeabilities will be below expected values. In addition, permeability is underestimated due to misinterpreting surface-roughness features as small pore throats. Comparison of permeability pre- dictions with expected and measured permeability values showed that the largest discrepancies resulted from the highest resolution images and the best predictions of permeability will result from images between 2 and 4 lm resolution. To reduce permeability underestimation from analyses of high-resolu- tion images, a resolution threshold between 3 and 15 lm was found to be effective, but it is not known whether this range is applicable beyond the samples studied here.

Beckingham, Lauren E.; Peters, Catherine A.; Um, Wooyong; Jones, Keith W.; Lindquist, W.Brent

2013-09-03T23:59:59.000Z

120

Invited Article: Coherent imaging using seeded free-electron laser pulses with variable polarization: First results and research opportunities  

SciTech Connect (OSTI)

FERMI-Elettra, the first vacuum ultraviolet and soft X-ray free-electron laser (FEL) using by default a 'seeded' scheme, became operational in 2011 and has been opened to users since December 2012. The parameters of the seeded FERMI FEL pulses and, in particular, the superior control of emitted radiation in terms of spectral purity and stability meet the stringent requirements for single-shot and resonant coherent diffraction imaging (CDI) experiments. The advantages of the intense seeded FERMI pulses with variable polarization have been demonstrated with the first experiments performed using the multipurpose experimental station operated at the diffraction and projection imaging (DiProI) beamline. The results reported here were obtained with fixed non-periodic targets during the commissioning period in 2012 using 20-32 nm wavelength range. They demonstrate that the performance of the FERMI FEL source and the experimental station meets the requirements of CDI, holography, and resonant magnetic scattering in both multi- and single-shot modes. Moreover, we present the first magnetic scattering experiments employing the fully circularly polarized FERMI pulses. The ongoing developments aim at pushing the lateral resolution by using shorter wavelengths provided by double-stage cascaded FERMI FEL-2 and probing ultrafast dynamic processes using different pump-probe schemes, including jitter-free seed laser pump or FEL-pump/FEL-probe with two color FEL pulses generated by the same electron bunch.

Capotondi, F.; Pedersoli, E.; Mahne, N.; Menk, R. H.; Passos, G.; Raimondi, L.; Svetina, C.; Sandrin, G.; Kiskinova, M. [FERMI, Elettra-Sincrotrone Trieste, SS 14 - km 163.5, 34149 Basovizza, Trieste (Italy); Zangrando, M. [FERMI, Elettra-Sincrotrone Trieste, SS 14 - km 163.5, 34149 Basovizza, Trieste (Italy); CNR, Istituto Officina dei Materiali - TASC, SS 14 - km 163.5, 34149 Basovizza, Trieste (Italy); Bajt, S.; Barthelmess, M.; Fleckenstein, H.; Chapman, H. N. [CFEL-DESY, Notkestrasse 85, 22607 Hamburg (Germany); Schulz, J. [European XFEL GmbH, Albert-Einstein-Ring 19, 22761 Hamburg (Germany); Bach, J.; Froemter, R. [Universitaet Hamburg, Institut fuer Angewandte Physik, 20355 Hamburg (Germany); Schleitzer, S.; Mueller, L.; Gutt, C. [DESY, Notkestrasse 85, 22607 Hamburg (Germany); and others

2013-05-15T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Study of Fish Response Using Particle Image Velocimetry and High-Speed, High-Resolution Imaging  

SciTech Connect (OSTI)

Existing literature of previous particle image velocimetry (PIV) studies of fish swimming has been reviewed. Historically, most of the studies focused on the performance evaluation of freely swimming fish. Technological advances over the last decade, especially the development of digital particle image velocimetry (DPIV) technique, make possible more accurate, quantitative descriptions of the flow patterns adjacent to the fish and in the wake behind the fins and tail, which are imperative to decode the mechanisms of drag reduction and propulsive efficiency. For flows generated by different organisms, the related scales and flow regimes vary significantly. For small Reynolds numbers, viscosity dominates; for very high Reynolds numbers, inertia dominates, and three-dimensional complexity occurs. The majority of previous investigations dealt with the lower end of Reynolds number range. The fish of our interest, such as rainbow trout and spring and fall chinook salmon, fall into the middle range, in which neither viscosity nor inertia is negligible, and three-dimensionality has yet to dominate. Feasibility tests have proven the applicability of PIV to flows around fish. These tests have shown unsteady vortex shedding in the wake, high vorticity region and high stress region, with the highest in the pectoral area. This evident supports the observations by Nietzel et al. (2000) and Deng et al. (2004) that the operculum are most vulnerable to damage from the turbulent shear flow, because they are easily pried open, and the large vorticity and shear stress can lift and tear off scales, rupture or dislodge eyes, and damage gills. In addition, the unsteady behavior of the vortex shedding in the wake implies that injury to fish by the instantaneous flow structures would likely be much higher than the injury level estimated using the average values of the dynamics parameters. Based on existing literature, our technological capability, and relevance and practicability to Department of Energy's Hydropower Program, we identified three major research areas of interest: free swimming, the boundary layer over fish, and kinematic response of fish. We propose that the highest priority is to characterize the kinematic response of fish to different turbulent environments such as high shear/turbulence and hydrodynamic disturbances created by solid structures such as deflector and turbine runner blade; the next priority is to map the boundary layer over swimming fish; the last is to document the behavior of freely swimming fish, focusing on fish of our interest. Grid turbulence and Karman vortex street will be employed to map the boundary layers over fish and investigate the effects of environmental disturbances on the swimming performance of fish, because they are well established and documented in engineering literature and are representative of fish's swimming environments. Extreme conditions characteristic of turbine environments, such as strong shear environment and collision, will be investigated. Through controlled laboratory studies, the fish injury mechanism from different sources will be evaluated in isolation. The major goals are to: gain first-hand knowledge of the biological effects under such extreme hydraulic environments in which fish could lack the capability to overcome the perturbations and be vulnerable to injury; Better understand field results by integrating the laboratory studies with the responses of sensor fish device; More importantly, provide well-defined validation cases and boundary conditions for geometry-based computational fluid-structure interaction modeling in order to simulate the complex hydraulic environments in advanced hydropower systems and their effects on fish, greatly enhancing the potential to use CFD as a bio-hydraulic design alternative.

Deng, Zhiqun; Richmond, Marshall C.; Guensch, Gregory R.; Mueller, Robert P.

2004-10-23T23:59:59.000Z

122

Fully-automatic laser welding and micro-sculpting with universal in situ inline coherent imaging  

E-Print Network [OSTI]

Though new affordable high power laser technologies make possible many processing applications in science and industry, depth control remains a serious technical challenge. Here we show that inline coherent imaging, with line rates up to 312 kHz and microsecond-duration capture times, is capable of directly measuring laser penetration depth in a process as violent as kW-class keyhole welding. We exploit ICI's high speed, high dynamic range and robustness to interference from other optical sources to achieve fully automatic, adaptive control of laser welding as well as ablation, achieving micron-scale sculpting in vastly different heterogeneous biological materials.

Webster, Paul J L; Ji, Yang; Galbraith, Christopher M; Kinross, Alison W; Van Vlack, Cole; Fraser, James M

2014-01-01T23:59:59.000Z

123

A new spectrometer design for the x-ray spectroscopy of laser-produced plasmas with high (sub-ns) time resolution  

SciTech Connect (OSTI)

This paper describes a new type of x-ray crystal spectrometer, which can be used in combination with gated x-ray detectors to obtain spectra from laser-produced plasmas with a high (sub-ns) time resolution. The spectrometer consists of a convex, spherically bent crystal, which images individual spectral lines as perfectly straight lines across multiple, sequentially gated, strip detectors. Since the Bragg-reflected rays are divergent, the distance between detector and crystal is arbitrary, so that this distance can be appropriately chosen to optimize the experimental arrangement with respect to the detector parameters. The spectrometer concept was verified in proof-of-principle experiments by imaging the L?{sub 1}- and L?{sub 2}-lines of tungsten, at 9.6735 and 9.96150 keV, from a micro-focus x-ray tube with a tungsten target onto a two-dimensional pixilated Pilatus detector, using a convex, spherically bent Si-422 crystal with a radius of curvature of 500 mm.

Bitter, M., E-mail: bitter@pppl.gov; Hill, K. W.; Efthimion, P. C.; Delgado-Aparicio, L.; Pablant, N. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Lu, Jian [Department of Engineering, Chongqing University, Chongqing 400044 (China); Beiersdorfer, P.; Chen, Hui [Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

2014-11-15T23:59:59.000Z

124

Phys. Med. Biol. 43 (1998) 10011013. Printed in the UK PII: S0031-9155(98)90627-3 High-resolution 3D Bayesian image reconstruction using  

E-Print Network [OSTI]

-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner Jinyi Qi, Richard M Leahy of high-resolution 3D images from the microPET small-animal scanner. Resolution recovery is achieved 2 mm when using an analytic 3D reprojection (3DRP) method with a ramp filter. These results also

Leahy, Richard M.

125

High resolution soft x-ray spectroscopy of low Z K-shell emission from laser-produced plasmas  

SciTech Connect (OSTI)

A large radius, R = 44.3 m, High Resolution Grating Spectrometer (HRGS) with 2400 line/mm variable line spacing has been designed for laser-produced plasma experiments conducted at the Lawrence Livermore National Laboratory Jupiter Laser Facility. The instrument has been run with a low-noise, charge-coupled device detector to record high signal-to-noise spectra in the 10-50 {angstrom} wavelength range. The instrument can be run with a 10-20 {micro}m wide slit to achieve the best spectral resolving power, approaching 1000 and similar to crystal spectrometers at 12-20 {angstrom}, or in slitless operation with a small symmetrical emission source. We describe preliminary spectra emitted from various H-like and He-like low Z ion plasmas heated by 100-500 ps (FWHM), 527 nm wavelength laser pulses. This instrument can be developed as a useful spectroscopy platform relevant to laboratory-based astrophysics as well as high energy density plasma studies.

Dunn, J; Magee, E W; Shepherd, R; Chen, H; Hansen, S B; Moon, S J; Brown, G V; Gu, M; Beiersdorfer, P; Purvis, M A

2008-05-21T23:59:59.000Z

126

Multiple hot images from an obscuration in an intense laser beam through cascaded Kerr medium disks  

SciTech Connect (OSTI)

We present a theoretical investigation on the formation of hot images in an intense laser beam through cascaded Kerr medium disks, to disclose the distribution and intensity of hot images in high-power disk amplifiers. It is shown that multiple hot images from an obscuration may be formed, instead of one hot image as reported previously in the literature. This gives a clear explanation for the curious damage pattern of hot images, namely, damage sites appearing on alternating optics in periodic trains. Further analysis demonstrates that the distribution and intensity of hot images depend closely on the number of Kerr medium disks, the distance from the obscuration to the front of the first disk downstream, the space between two neighboring disks, and the thickness and B integral of each disk. Moreover, we take two cascaded Kerr medium disks for example to detail multiple hot images from an obscuration and confirm the theoretical results by numerical simulations.

Wang Youwen; Wen Shuangchun; You Kaiming; Tang Zhixiang; Deng Jianqin; Zhang Lifu; Fan Dianyuan

2008-10-20T23:59:59.000Z

127

Whole-brain calcium imaging with cellular resolution in freely behaving C. elegans  

E-Print Network [OSTI]

The ability to acquire large-scale recordings of neuronal activity in awake and unrestrained animals poses a major challenge for studying neural coding of animal behavior. We present a new instrument capable of recording intracellular calcium transients from every neuron in the head of a freely behaving C. elegans with cellular resolution while simultaneously recording the animal's position, posture and locomotion. We employ spinning-disk confocal microscopy to capture 3D volumetric fluorescent images of neurons expressing the calcium indicator GCaMP6s at 5 head-volumes per second. Two cameras simultaneously monitor the animal's position and orientation. Custom software tracks the 3D position of the animal's head in real-time and adjusts a motorized stage to keep it within the field of view as the animal roams freely. We observe calcium transients from 78 neurons and correlate this activity with the animal's behavior. Across worms, multiple neurons show significant correlations with modes of behavior correspo...

Nguyen, Jeffrey P; Linder, Ashley N; Plummer, George S; Shaevitz, Joshua W; Leifer, Andrew M

2015-01-01T23:59:59.000Z

128

Ultrafast supercontinuum fiber-laser based pump-probe scanning magneto-optical Kerr effect microscope for the investigation of electron spin dynamics in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution  

SciTech Connect (OSTI)

We describe a two-color pump-probe scanning magneto-optical Kerr effect microscope which we have developed to investigate electron spin phenomena in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution. The key innovation of our microscope is the usage of an ultrafast “white light” supercontinuum fiber-laser source which provides access to the whole visible and near-infrared spectral range. Our Kerr microscope allows for the independent selection of the excitation and detection energy while avoiding the necessity to synchronize the pulse trains of two separate picosecond laser systems. The ability to independently tune the pump and probe wavelength enables the investigation of the influence of excitation energy on the optically induced electron spin dynamics in semiconductors. We demonstrate picosecond real-space imaging of the diffusive expansion of optically excited electron spin packets in a (110) GaAs quantum well sample to illustrate the capabilities of the instrument.

Henn, T.; Kiessling, T., E-mail: tobias.kiessling@physik.uni-wuerzburg.de; Ossau, W.; Molenkamp, L. W. [Physikalisches Institut (EP3), Universität Würzburg, 97074 Würzburg (Germany)] [Physikalisches Institut (EP3), Universität Würzburg, 97074 Würzburg (Germany); Biermann, K.; Santos, P. V. [Paul-Drude-Institut für Festkörperelektronik, 10117 Berlin (Germany)] [Paul-Drude-Institut für Festkörperelektronik, 10117 Berlin (Germany)

2013-12-15T23:59:59.000Z

129

Extensive simulation studies on the reconstructed image resolution of a position sensitive detector based on pixelated CdTe crystals  

E-Print Network [OSTI]

We present results on the reconstructed image resolution of a position sensitive radiation instrument (COCAE) based on extensive simulation studies. The reconstructed image resolution has been investigated in a wide range of incident photon energies emitted by point-like sources located at different source-to-detector distances on and off the detector's symmetry axis. The ability of the detector to distinguish multiple radioactive sources observed simultaneously is investigating by simulating point-like sources of different energies located on and off the detector's symmetry axis and at different positions

Zachariadou, K; Kaissas, I; Seferlis, S; Lambropoulos, C; Loukas, D; Potiriadis, C

2011-01-01T23:59:59.000Z

130

Extensive simulation studies on the reconstructed image resolution of a position sensitive detector based on pixelated CdTe crystals  

E-Print Network [OSTI]

We present results on the reconstructed image resolution of a position sensitive radiation instrument (COCAE) based on extensive simulation studies. The reconstructed image resolution has been investigated in a wide range of incident photon energies emitted by point-like sources located at different source-to-detector distances on and off the detector's symmetry axis. The ability of the detector to distinguish multiple radioactive sources observed simultaneously is investigating by simulating point-like sources of different energies located on and off the detector's symmetry axis and at different positions

K. Zachariadou; K. Karafasoulis; I. Kaissas; S. Seferlis; C. Lambropoulos; D. Loukas; C. Potiriadis

2011-11-26T23:59:59.000Z

131

Enhancement of the resolution of full-field optical coherence tomography by using a colour image sensor  

SciTech Connect (OSTI)

The influence of white balance in a colour image detector on the resolution of a full-field optical coherence tomograph (FFOCT) is studied. The change in the interference pulse width depending on the white balance tuning is estimated in the cases of a thermal radiation source (incandescent lamp) and a white light emitting diode. It is shown that by tuning white balance of the detector in a certain range, the FFOCT resolution can be increased by 20 % as compared to the resolution, attained with the use of a monochrome detector. (optical coherence tomography)

Kalyanov, A L; Lychagov, V V; Smirnov, I V; Ryabukho, V P [N.G. Chernyshevsky Saratov State University, Saratov (Russian Federation)

2013-08-31T23:59:59.000Z

132

ALBOTA ET AL. Three-Dimensional Imaging Laser Radars with Geiger-Mode Avalanche Photodiode Arrays  

E-Print Network [OSTI]

· ALBOTA ET AL. Three-Dimensional Imaging Laser Radars with Geiger-Mode Avalanche Photodiode Arrays- lanche photodiodes (APDs) operating in Geiger mode, with integrated timing circuitry for each pixel [2-Mode Avalanche Photodiode Arrays Marius A. Albota, Brian F. Aull, Daniel G. Fouche, Richard M. Heinrichs, David G

133

Terahertz imaging and quantum cascade laser based devices  

E-Print Network [OSTI]

The terahertz (THz) frequency range (f=0.3-10 THz, [lambda]=30-1000 lam) is much less technologically developed that the adjacent microwave and infrared frequency ranges, but offers several advantages for imaging applications: ...

Lee, Alan Wei Min

2010-01-01T23:59:59.000Z

134

Generative Models for Super-Resolution Single Molecule Microscopy Images of Biological Structures  

E-Print Network [OSTI]

an information bridge between super-resolution microscopy and structural biology by using generative models

Matsuda, Noboru

135

Laser speckle-imaging of blood microcirculation in the brain cortex of laboratory rats in stress  

SciTech Connect (OSTI)

The results of experimental approbation of the method of laser full-field speckle-imaging for monitoring the changes in blood microcirculation state of the brain cortex of laboratory rats under the conditions of developing stroke and administration of vasodilating and vasoconstrictive agents are presented. The studies aimed at the choice of the optimal conditions of speckle-image formation and recording were performed and the software implementing an adaptive algorithm for processing the data of measurements was created. The transfer of laser radiation to the probed region of the biotissue was implemented by means of a silica-polymer optical fibre. The problems and prospects of speckle-imaging of cerebral microcirculation of blood in laboratory and clinical conditions are discussed.

Vilensky, M A; Semyachkina-Glushkovskaya, Oxana V; Timoshina, P A; Kuznetsova, Jana V; Semyachkin-Glushkovskii, I A; Agafonov, Dmitry N; Tuchin, Valerii V

2012-06-30T23:59:59.000Z

136

High-resolution multi-MeV x-ray radiography using relativistic laser-solid interaction  

SciTech Connect (OSTI)

When high intensity ({>=}10{sup 19} W cm{sup -2}) laser light interacts with matter, multi-MeV electrons are produced. These electrons can be utilized to generate a MeV bremsstrahlung x-ray emission spectrum as they propagate into a high-Z solid target positioned behind the interaction area. The short duration (<10 ps) and the small diameter (<500 {mu}m) of the x-ray pulse combined with the MeV x-ray spectrum offers an interesting alternative to conventional bremsstrahlung x-ray sources based on an electron accelerator used to radiograph dense, rapidly moving objects. In experiments at the Omega EP laser, a multi-MeV x-ray source is characterized consistently with number of independent diagnostics. An unfiltered x-ray dose of approximately 2 rad in air at 1 m and a source diameter of less than 350 {mu}m are inferred. Radiography of a complex and high area density (up to 61 g/cm{sup 2}) object is then performed with few hundred microns spatial resolution.

Courtois, C.; Compant La Fontaine, A.; Barbotin, M.; Bazzoli, S.; Brebion, D.; Bourgade, J. L.; Gazave, J.; Lagrange, J. M.; Landoas, O.; Le Dain, L.; Lefebvre, E.; Pichoff, N. [CEA, DAM, DIF, F-91297 Arpajon (France); Edwards, R.; Aedy, C.; Biddle, L.; Drew, D.; Gardner, M.; Ramsay, M.; Simons, A.; Sircombe, N. [AWE Plc., Aldermaston, Reading RG7 4PR (United Kingdom)

2011-02-15T23:59:59.000Z

137

Aerosols in the Caribbean MidAtlantic Region as Observed with the EOS Moderate Resolution Imaging Spectroradiometer (MODIS)  

E-Print Network [OSTI]

Aerosols in the Caribbean MidAtlantic Region as Observed with the EOS Moderate Resolution Imaging the year, changes in precipitation patterns and greater health risks for the Caribbean region during the spring months. Keywords: MODIS, MODIS Conversion Toolkit, aerosols, Caribbean region INTRODUCTION

Gilbes, Fernando

138

Laser radar VI; Proceedings of the Meeting, Los Angeles, CA, Jan. 23-25, 1991  

SciTech Connect (OSTI)

Topics presented include lidar wind shear detection for commercial aircraft, centroid tracking of range-Doppler images, an analytic approach to centroid performance analysis, simultaneous active/passive IR vehicle detection, and resolution limits for high-resolution imaging lidar. Also presented are laser velocimetry applications, the application of laser radar to autonomous spacecraft landing, 3D laser radar simulation for autonomous spacecraft landing, and ground based CW atmospheric Doppler lidar performamce modeling.

Becherer, R.J.

1991-01-01T23:59:59.000Z

139

advanced high resolution: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Resolution Imaging Spectrometer (MODIS) to calibrate advanced very high resolution radiometer Geosciences Websites Summary: Using Moderate Resolution Imaging Spectrometer (MODIS)...

140

High-Resolution Radio Imaging of Gravitational Lensing Candidates in the 1 Jansky BL Lac Sample  

E-Print Network [OSTI]

While BL Lacertae objects are widely believed to be highly beamed, low-luminosity radio galaxies, many radio-selected BL Lacs have extended radio power levels and optical emission lines that are too luminous to be low-luminosity radio galaxies. Also, Stocke & Rector discovered an excess of MgII absorption systems along BL Lac sightlines compared to quasars, suggesting that gravitational lensing may be another means of creating the BL Lac phenomenon in some cases. We present a search for gravitationally-lensed BL Lacs with deep, high-resolution, two-frequency VLA radio maps of seven lensing candidates from the 1 Jansky BL Lac sample. We find that none of these objects are resolved into an Einstein ring like B 0218+357, nor do any show multiple images of the core. All of the lensing candidates that were resolved show a flat-spectrum core and very unusual, steep-spectrum extended morphology that is incompatible with a multiply lensed system. Thus, while these observations do not rule out microlensing, no macrolensing is observed.

T. A. Rector; J. T. Stocke

2003-02-19T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Airborne laser induced fluorescence imaging. Innovative technology summary report  

SciTech Connect (OSTI)

Laser-Induced Fluorescence (LIF) was demonstration as part of the Fernald Environmental Management Project (FEMP) Plant 1 Large Scale Demonstration and Deployment Project (LSDDP) sponsored by the US Department of Energy (DOE) Office of Science and Technology, Deactivation and Decommissioning Focus Area located at the Federal Energy Technology Center (FETC) in Morgantown, West Virginia. The demonstration took place on November 19, 1996. In order to allow the contaminated buildings undergoing deactivation and decommissioning (D and D) to be opened to the atmosphere, radiological surveys of floors, walls and ceilings must take place. After successful completion of the radiological clearance survey, demolition of the building can continue. Currently, this process is performed by collecting and analyzing swipe samples for radiological analysis. Two methods are used to analyze the swipe samples: hand-held frisker and laboratory analysis. For the purpose of this demonstration, the least expensive method, swipe samples analyzed by hand-held frisker, is the baseline technology. The objective of the technology demonstration was to determine if the baseline technology could be replaced using LIF.

NONE

1999-06-01T23:59:59.000Z

142

Laser Ablation Sampling of Materials Directly into the Formed Liquid Microjunction of a Continuous Flow Surface Sampling Probe/Electrospray Ionization Emitter for Mass Spectral Analysis and Imaging  

SciTech Connect (OSTI)

Transmission geometry laser ablation directly into a formed liquid microjunction of a continuous flow liquid microjunction surface sampling probe/electrospray ionization emitter was utilized for molecular and elemental detection and mass spectrometry imaging. The ability to efficiently capture and ionize ablated material was demonstrated by the detection of various small soluble n-mers of polyaniline and silver ion solvent clusters formed from laser ablation of electropolymerized polyaniline and silver thin films, respectively. In addition, analysis of surfaces that contain soluble components was accomplished by coating or laminating the sample with an insoluble film to enable liquid junction formation without directly extracting material from the surface. The ability to perform mass spectrometry imaging at a spatial resolution of about 50 m was illustrated by using laminated inked patterns on a microscope slide. In general, these data demonstrate at least an order of magnitude signal enhancement compared to the non-contact, laser ablation droplet capture-based surface sampling/ionization approaches that have been previously presented.

Ovchinnikova, Olga S [ORNL] [ORNL; Lorenz, Matthias [ORNL] [ORNL; Kertesz, Vilmos [ORNL] [ORNL; Van Berkel, Gary J [ORNL] [ORNL

2013-01-01T23:59:59.000Z

143

Denoising of PET images by combining wavelets and curvelets for improved preservation of resolution and quantitation  

E-Print Network [OSTI]

1 Denoising of PET images by combining wavelets and curvelets for improved preservation of Positron Emission Tomography (PET) images is a challenging task due to the inherent low signal evaluation of Positron Emission Tomography (PET) images often involve pre- processing steps. As PET images

Paris-Sud XI, Université de

144

High-resolution imaging of vessels in the isolated rat brain M. F. Valverde Salzmann1  

E-Print Network [OSTI]

into a test tube filled with fluorocarbon fluid for susceptibility matching. MR Images were acquired

145

Investigation of a high spatial resolution method based on polar coordinate maximum entropy method for analyzing electron density fluctuation data measured by laser phase contrast  

SciTech Connect (OSTI)

Laser phase contrast is a powerful diagnostic method to determine the spatial distribution of electron density fluctuations in magnetically confined plasmas, although its applicability depends on magnetic field configurations. The spatial resolution of fluctuations is linked with the resolution of the propagation direction that is derived from the two-dimensional spectral analysis of the wavenumber for the fluctuations. The method was applied to fluctuation measurements in a compact helical system. In order to improve the resolution of the propagation direction with a relatively small number of data points, the maximum entropy method with polar coordinates was employed. A spatial resolution of the order of 1 cm was obtained, which is satisfactory in a plasma with a 20 cm minor radius.

Matsuo, K. [Fukuoka Institute of Technology, Fukuoka 811-0295 (Japan); Iguchi, H.; Okamura, S.; Matsuoka, K. [National Institute for Fusion Science, Toki 509-5292 (Japan)

2012-01-15T23:59:59.000Z

146

IMPLICATIONS OF A HIGH ANGULAR RESOLUTION IMAGE OF THE SUNYAEV-ZEL'DOVICH EFFECT IN RXJ1347-1145  

SciTech Connect (OSTI)

The most X-ray luminous cluster known, RXJ1347-1145 (z = 0.45), has been the object of extensive study across the electromagnetic spectrum. We have imaged the Sunyaev-Zel'dovich effect (SZE) at 90 GHz ({lambda} = 3.3 mm) in RXJ1347-1145 at 10'' resolution with the 64 pixel MUSTANG bolometer array on the Green Bank Telescope, confirming a previously reported strong, localized enhancement of the SZE 20'' to the southeast of the center of X-ray emission. This enhancement of the SZE has been interpreted as shock-heated (>20 keV) gas caused by an ongoing major (low mass ratio) merger event. Our data support this interpretation. We also detect a pronounced asymmetry in the projected cluster pressure profile, with the pressure just east of the cluster core {approx}1.6x higher than just to the west. This is the highest resolution image of the SZE made to date.

Mason, B. S.; Cotton, W. D. [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States); Dicker, S. R.; Korngut, P. M.; Devlin, M. J.; Aguirre, J. E. [University of Pennsylvania, 209 South 33rd Street, Philadelphia, PA 19104 (United States); Koch, P. M.; Molnar, S. M. [Institute of Astronomy and Astrophysics, Academia Sinica, P.O. Box 23-141, Taipei 10617, Taiwan (China); Sievers, J. [The Canadian Institute of Theoretical Astrophysics, 60 St. George Street, Toronto, Ontario M5S 3H8 (Canada); Benford, D.; Staguhn, J. G.; Moseley, H. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Irwin, K. D. [National Institute of Standards and Technology, 325 Broadway, Boulder, CO 80303 (United States); Ade, P., E-mail: bmason@nrao.ed [School of Physics and Astronomy, Cardiff University, 5 The Parade, Cardiff CF24 3AA (United Kingdom)

2010-06-10T23:59:59.000Z

147

Low-spatial coherence electrically-pumped semiconductor laser for speckle-free full-field imaging  

E-Print Network [OSTI]

The spatial coherence of laser sources has limited their application to parallel imaging and projection due to coherent artifacts, such as speckle. In contrast, traditional incoherent light sources, such as thermal sources or light emitting diodes (LEDs), provide relatively low power per independent spatial mode. Here, we present a chip-scale, electrically-pumped semiconductor laser based on a novel design, demonstrating high power per mode with much lower spatial coherence than conventional laser sources. The laser resonator was fabricated with a chaotic, D-shaped cavity optimized to achieve highly multimode lasing. Lasing occurs simultaneously and independently in ~1000 modes, and hence the total emission exhibits very low spatial coherence. Speckle-free full-field imaging is demonstrated using the chaotic cavity laser as the illumination source. The power per mode of the sample illumination is several orders of magnitude higher than that of a LED or thermal light source. Such a compact, low-cost source, wh...

Redding, B; Huang, X; Lee, M L; Stone, A D; Choma, M A; Cao, H

2014-01-01T23:59:59.000Z

148

High energy resolution hard X-ray and gamma-ray imagers using CdTe diode devices  

E-Print Network [OSTI]

We developed CdTe double-sided strip detectors (DSDs or cross strip detectors) and evaluated their spectral and imaging performance for hard X-rays and gamma-rays. Though the double-sided strip configuration is suitable for imagers with a fine position resolution and a large detection area, CdTe diode DSDs with indium (In) anodes have yet to be realized due to the difficulty posed by the segmented In anodes. CdTe diode devices with aluminum (Al) anodes were recently established, followed by a CdTe device in which the Al anodes could be segmented into strips. We developed CdTe double-sided strip devices having Pt cathode strips and Al anode strips, and assembled prototype CdTe DSDs. These prototypes have a strip pitch of 400 micrometer. Signals from the strips are processed with analog ASICs (application specific integrated circuits). We have successfully performed gamma-ray imaging spectroscopy with a position resolution of 400 micrometer. Energy resolution of 1.8 keV (FWHM: full width at half maximum) was ob...

Watanabe, Shin; Aono, Hiroyuki; Takeda, Shin'ichiro; Odaka, Hirokazu; Kokubun, Motohide; Takahashi, Tadayuki; Nakazawa, Kazuhiro; Tajima, Hiroyasu; Onishi, Mitsunobu; Kuroda, Yoshikatsu

2008-01-01T23:59:59.000Z

149

High-speed high-resolution plasma spectroscopy using spatial-multiplex coherence imaging techniques  

E-Print Network [OSTI]

, laser Thomson scattering and infrared thermography [1­3] . When the spectral content of a scene can, thermography, bremsstrahlung, Thomson scattering), it is often the case that these parameters can be recovered

Howard, John

150

D&D Toolbox Robotic Deployment of High Resolution Laser Imaging for Characterization  

Broader source: Energy.gov [DOE]

The characterization of complex and/or hazardous facilities for the purposes of planning D&D projects can be excessively time consuming and present unacceptable hazards for personnel who enter...

151

High-resolution 3-D refractive index imaging and Its biological applications  

E-Print Network [OSTI]

This thesis presents a theory of 3-D imaging in partially coherent light under a non-paraxial condition. The transmission cross-coefficient (TCC) has been used to characterize partially coherent imaging in a 2- D and 3-D ...

Sung, Yongjin

2011-01-01T23:59:59.000Z

152

High-resolution measurements of the spatial and temporal evolution of megagauss magnetic fields created in intense short-pulse laser-plasma interactions  

SciTech Connect (OSTI)

A pump-probe polarimetric technique is demonstrated, which provides a complete, temporally and spatially resolved mapping of the megagauss magnetic fields generated in intense short-pulse laser-plasma interactions. A normally incident time-delayed probe pulse reflected from its critical surface undergoes a change in its ellipticity according to the magneto-optic Cotton-Mouton effect due to the azimuthal nature of the ambient self-generated megagauss magnetic fields. The temporal resolution of the magnetic field mapping is typically of the order of the pulsewidth, limited by the laser intensity contrast, whereas a spatial resolution of a few ?m is achieved by this optical technique. High-harmonics of the probe can be employed to penetrate deeper into the plasma to even near-solid densities. The spatial and temporal evolution of the megagauss magnetic fields at the target front as well as at the target rear are presented. The ?m-scale resolution of the magnetic field mapping provides valuable information on the filamentary instabilities at the target front, whereas probing the target rear mirrors the highly complex fast electron transport in intense laser-plasma interactions.

Chatterjee, Gourab, E-mail: gourab@tifr.res.in; Singh, Prashant Kumar; Adak, Amitava; Lad, Amit D.; Kumar, G. Ravindra, E-mail: grk@tifr.res.in [Tata Institute of Fundamental Research, 1 Homi Bhabha Road, Mumbai 400 005 (India)

2014-01-15T23:59:59.000Z

153

Spectroscopic characterization and imaging of laser- and unipolar arc-induced plasmas  

SciTech Connect (OSTI)

Tungsten plasmas induced by unipolar arcs were investigated using optical emission spectroscopy and imaging, and compared with laser-induced tungsten plasmas. The unipolar arcs were initiated in the linear-plasma simulator PISCES-A at UCSD under fusion relevant conditions. The electron temperature and density of the unipolar arc plasmas were in the range 0.5–0.7?eV and 0.7–2.0?×?10{sup 20?}m{sup ?3}, respectively, and increased with increasing negative bias voltage, but did not correlate with the surface temperature. In comparison, the electron temperature and density of the laser-induced plasmas were in the range 0.6–1.4?eV and 7?×?10{sup 19}–1?×?10{sup 22?}m{sup ?3}, respectively.

Aussems, Damien U. B., E-mail: d.aussems@differ.nl [FOM Institute DIFFER—Dutch Institute for Fundamental Energy Research, Nieuwegein, NL-3430 BE (Netherlands); Nishijima, Daisuke; Brandt, Christian; Doerner, Russell P. [Center for Energy Research, University of California at San Diego, 9500 Gilman Drive, La Jolla, California 92093-0417 (United States); Cardozo, Niek J. Lopes [Science and Technology of Nuclear Fusion, Eindhoven University of Technology, Eindhoven 5612 AZ (Netherlands)

2014-08-14T23:59:59.000Z

154

Developments in limited data image reconstruction techniques for ultrahigh-resolution x-ray tomographic imaging of microchips  

SciTech Connect (OSTI)

The use of soft x-ray (about 1.8 KeV) nanotomography techniques for the evaluation and failure mode analysis of microchips was investigated. Realistic numerical simulations of the imaging process were performed and a specialized approach to image reconstruction from limited projection data was devised. Prior knowledge of the structure and its component materials was used to eliminate artifacts in the reconstructed images so that defects and deviations from the original design could be visualized. Simulated data sets were generated with a total of 21 projections over three different angular ranges: -50 to +50, - 80 to +80 and -90 to +90 degrees. In addition, a low level of illumination was assumed. It was shown that sub-micron defects within one cell of a microchip (< 10 pm3) could be imaged in 3-D using such an approach.

Haddad, W.S.; Trebes, J.E.

1997-08-20T23:59:59.000Z

155

High-resolution three-dimensional imaging of red blood cells parasitized by Plasmodium falciparum and in situ hemozoin crystals using optical diffraction tomography  

E-Print Network [OSTI]

We present high-resolution optical tomographic images of human red blood cells (RBC) parasitized by malaria-inducing Plasmodium falciparum (Pf)-RBCs. Three-dimensional (3-D) refractive index (RI) tomograms are reconstructed ...

Kim, Kyoohyun

156

High-resolution ab initio three-dimensional x-ray diffraction microscopy  

DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

Coherent x-ray diffraction microscopy is a method of imaging nonperiodic isolated objects at resolutions limited, in principle, by only the wavelength and largest scattering angles recorded. We demonstrate x-ray diffraction imaging with high resolution in all three dimensions, as determined by a quantitative analysis of the reconstructed volume images. These images are retrieved from the three-dimensional diffraction data using no a priori knowledge about the shape or composition of the object, which has never before been demonstrated on a nonperiodic object. We also construct two-dimensional images of thick objects with greatly increased depth of focus (without loss of transverse spatial resolution). These methods can be used to image biological and materials science samples at high resolution with x-ray undulator radiation and establishes the techniques to be used in atomic-resolution ultrafast imaging at x-ray free-electron laser sources.

Chapman, Henry N.; Barty, Anton; Marchesini, Stefano; Noy, Aleksandr; Hau-Riege, Stefan P.; Cui, Congwu; Howells, Malcolm R.; Rosen, Rachel; He, Haifeng; Spence, John C.; Weierstall, Uwe; Beetz, Tobias; Jacobsen, Chris; Shapiro, David

2006-01-01T23:59:59.000Z

157

Digital Image Processing "Cookbook": A method to derive bathymetric data from high spatial resolution multi-  

E-Print Network [OSTI]

Digital Image Processing "Cookbook": A method to derive bathymetric data from high spatial;Processing Method: Overview 1) Viewing of Images Software: ENVI, ArcGIS 2) Data Conversion from DN (digital by step outline, with comments concerning processing methods and accuracy issues, for a methodology

Wright, Dawn Jeannine

158

CHANGE DETECTION FOR HIGH RESOLUTION SATELLITE IMAGES, BASED ON SIFT DESCRIPTORS AND AN A CONTRARIO APPROACH  

E-Print Network [OSTI]

promising results. Index Terms-- SAR image, SIFT, change detection, lo- cal descriptors, RANSAC, a contrario-registration step and works on pairs of either optical or SAR images. 2. CHANGE DETECTION FOR MULTI here to use a feature-based approach with no need for prior regis- tration and calibration. This method

Paris-Sud XI, Université de

159

Two-beam ultrabroadband coherent anti-Stokes Raman spectroscopy for high resolution gas-phase multiplex imaging  

SciTech Connect (OSTI)

We propose and develop a method for wideband coherent anti-Stokes Raman spectroscopy (CARS) in the gas phase and demonstrate the single-shot measurement of N{sub 2}, H{sub 2}, CO{sub 2}, O{sub 2}, and CH{sub 4}. Pure-rotational and vibrational O-, Q-, and S- branch spectra are collected simultaneously, with high spectral and spatial resolution, and within a single-laser-shot. The relative intensity of the rotational and vibrational signals can be tuned arbitrarily using polarization techniques. The ultrashort 7 fs pump and Stokes pulses are automatically overlapped temporally and spatially using a two-beam CARS technique, and the crossed probe beam allows for excellent spatial sectioning of the probed location.

Bohlin, Alexis; Kliewer, Christopher J., E-mail: cjkliew@sandia.gov [Combustion Research Facility, Sandia National Laboratories, Livermore, California 94550 (United States)

2014-01-20T23:59:59.000Z

160

High energy resolution hard X-ray and gamma-ray imagers using CdTe diode devices  

E-Print Network [OSTI]

We developed CdTe double-sided strip detectors (DSDs or cross strip detectors) and evaluated their spectral and imaging performance for hard X-rays and gamma-rays. Though the double-sided strip configuration is suitable for imagers with a fine position resolution and a large detection area, CdTe diode DSDs with indium (In) anodes have yet to be realized due to the difficulty posed by the segmented In anodes. CdTe diode devices with aluminum (Al) anodes were recently established, followed by a CdTe device in which the Al anodes could be segmented into strips. We developed CdTe double-sided strip devices having Pt cathode strips and Al anode strips, and assembled prototype CdTe DSDs. These prototypes have a strip pitch of 400 micrometer. Signals from the strips are processed with analog ASICs (application specific integrated circuits). We have successfully performed gamma-ray imaging spectroscopy with a position resolution of 400 micrometer. Energy resolution of 1.8 keV (FWHM: full width at half maximum) was obtained at 59.54 keV. Moreover, the possibility of improved spectral performance by utilizing the energy information of both side strips was demonstrated. We designed and fabricated a new analog ASIC, VA32TA6, for the readout of semiconductor detectors, which is also suitable for DSDs. A new feature of the ASIC is its internal ADC function. We confirmed this function and good noise performance that reaches an equivalent noise charge of 110 e- under the condition of 3-4 pF input capacitance.

Shin Watanabe; Shin-nosuke Ishikawa; Hiroyuki Aono; Shin'ichiro Takeda; Hirokazu Odaka; Motohide Kokubun; Tadayuki Takahashi; Kazuhiro Nakazawa; Hiroyasu Tajima; Mitsunobu Onishi; Yoshikatsu Kuroda

2008-11-04T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Imaging single cells in a beam of live cyanobacteria with an X-ray laser  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Diffraction pattern of a micron-sized S. elongatus cell at 1,100 eV photon energy (1.13 nm wavelength) with ~10^11 photons per square micron on the sample in ~70 fs. The signal to noise ratio at 4 nm resolution is 3.7 with 0.24 photons per Nyquist pixel. The cell was alive at the time of the exposure. The central region of the pattern (dark red) is saturated and this prevented reliable image reconstruction.

Schot, Gijs, vander

162

Taheri-Saramad x-ray detector (TSXD): A novel high spatial resolution x-ray imager based on ZnO nano scintillator wires in polycarbonate membrane  

SciTech Connect (OSTI)

A novel x-ray imager based on ZnO nanowires is designed and fabricated. The proposed architecture is based on scintillation properties of ZnO nanostructures in a polycarbonate track-etched membrane. Because of higher refractive index of ZnO nanowire compared to the membrane, the nanowire acts as an optical fiber that prevents the generated optical photons to spread inside the detector. This effect improves the spatial resolution of the imager. The detection quantum efficiency and spatial resolution of the fabricated imager are 11% and <6.8 ?m, respectively.

Taheri, A., E-mail: at1361@aut.ac.ir; Saramad, S.; Ghalenoei, S.; Setayeshi, S. [Department of Energy Engineering and Physics, Amirkabir University of Technology, Tehran 15875-4413 (Iran, Islamic Republic of)] [Department of Energy Engineering and Physics, Amirkabir University of Technology, Tehran 15875-4413 (Iran, Islamic Republic of)

2014-01-15T23:59:59.000Z

163

Background and Scattered Light Subtraction in the High-Resolution Echelle Modes of the Space Telescope Imaging Spectrograph  

E-Print Network [OSTI]

We present a simple, effective approach for estimating the on-order backgrounds of spectra taken with the highest-resolution modes of the Space Telescope Imaging Spectrograph (STIS) on-board the Hubble Space Telescope. Our scheme for determining the on-order background spectrum uses polynomial fits to the inter-order scattered light visible in the two-dimensional STIS MAMA images. We present a suite of high-resolution STIS spectra to demonstrate that our background subtraction routine produces the correct overall zero point, as judged by the small residual flux levels in the centers of strongly-saturated interstellar absorption lines. Although there are multiple sources of background light in STIS echelle mode data, this simple approach works very well for wavelengths longward of Lyman-alpha. At shorter wavelengths, the smaller order separation and generally lower signal-to-noise ratios of the data can reduce the effectiveness of our background estimation procedure. Slight artifacts in the background-subtracted spectrum can be seen in some cases, particularly at wavelengths <1300 Ang. Most of these are caused by echelle scattering of strong spectral features into the inter-order light. We discuss the limitations of high-resolution STIS data in light of the uncertainties associated with our background subtraction procedure. We compare our background-subtracted STIS spectra with GHRS Ech-A observations of the DA white dwarf G191-B2B and GHRS first-order G160M observations of the early-type star HD 218915. We find no significant differences between the GHRS data and the STIS data reduced with our method in either case.

J. Christopher Howk; Kenneth R. Sembach

1999-12-17T23:59:59.000Z

164

Magnetoacoustic tomography with magnetic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet  

SciTech Connect (OSTI)

Purpose: Magnetoacoustic tomography with magnetic induction (MAT-MI) is an imaging modality to reconstruct the electrical conductivity of biological tissue based on the acoustic measurements of Lorentz force induced tissue vibration. This study presents the feasibility of the authors' new MAT-MI system and vector source imaging algorithm to perform a complete reconstruction of the conductivity distribution of real biological tissues with ultrasound spatial resolution. Methods: In the present study, using ultrasound beamformation, imaging point spread functions are designed to reconstruct the induced vector source in the object which is used to estimate the object conductivity distribution. Both numerical studies and phantom experiments are performed to demonstrate the merits of the proposed method. Also, through the numerical simulations, the full width half maximum of the imaging point spread function is calculated to estimate of the spatial resolution. The tissue phantom experiments are performed with a MAT-MI imaging system in the static field of a 9.4 T magnetic resonance imaging magnet. Results: The image reconstruction through vector beamformation in the numerical and experimental studies gives a reliable estimate of the conductivity distribution in the object with a ?1.5 mm spatial resolution corresponding to the imaging system frequency of 500 kHz ultrasound. In addition, the experiment results suggest that MAT-MI under high static magnetic field environment is able to reconstruct images of tissue-mimicking gel phantoms and real tissue samples with reliable conductivity contrast. Conclusions: The results demonstrate that MAT-MI is able to image the electrical conductivity properties of biological tissues with better than 2 mm spatial resolution at 500 kHz, and the imaging with MAT-MI under a high static magnetic field environment is able to provide improved imaging contrast for biological tissue conductivity reconstruction.

Mariappan, Leo; Hu, Gang [Department of Biomedical Engineering, University of Minnesota, Minnesota 55455 (United States)] [Department of Biomedical Engineering, University of Minnesota, Minnesota 55455 (United States); He, Bin, E-mail: binhe@umn.edu [Department of Biomedical Engineering, University of Minnesota, Minnesota 55455 and Institute of Engineering in Medicine, University of Minnesota, Minnesota 55455 (United States)] [Department of Biomedical Engineering, University of Minnesota, Minnesota 55455 and Institute of Engineering in Medicine, University of Minnesota, Minnesota 55455 (United States)

2014-02-15T23:59:59.000Z

165

Supporting Online Material High resolution electroluminescent imaging of pressure distribution using a  

E-Print Network [OSTI]

modeling of basic mechanics and physics C: Devices fabrication process and hydrothermal growth of nanowires emitting intensity change with image acquisition and processing technologies. Figure S1 | Schematic diagram by hydrothermal methods. (Fig. S4) (3) Spacing is very important for the device, and there is an optimum spacing

Wang, Zhong L.

166

High-resolution, rapid image acquisition for studying biological structures and dynamic cellular processes  

E-Print Network [OSTI]

can be fully integrated with their IX (inverted) and BX (upright) microscopes. The combination) with online analysis. The advanced autofocus gives consistently clear images, and TTL pulse triggering to specific functions are simply selected and linked together in the order required.These command icons

Cai, Long

167

Soft x-ray laser holography with wavelength P. W. Wachulak, M. C. Marconi,* R. A. Bartels, C. S. Menoni, and J. J. Rocca  

E-Print Network [OSTI]

Soft x-ray laser holography with wavelength resolution P. W. Wachulak, M. C. Marconi,* R. A the tabletop acquisition of soft x-ray holographic images of nanostructures with a spatial resolution of 46 using a compact, tabletop capillary-discharge soft x-ray laser emitting at 46.9 nm in a high

Rocca, Jorge J.

168

2354 IEEE TRANSACTIONS ON PLASMA SCIENCE, VOL. 39, NO. 11, NOVEMBER 2011 Laser Diagnostic Imaging of Energetically Enhanced  

E-Print Network [OSTI]

2354 IEEE TRANSACTIONS ON PLASMA SCIENCE, VOL. 39, NO. 11, NOVEMBER 2011 Laser Diagnostic Imaging of Energetically Enhanced Flames Using Direct Microwave Plasma Coupling Xing Rao, Stephen Hammack, Campbell Carter in plasma-enhanced flames, where a nonthermal microwave plasma discharge is coupled di- rectly

Lee, Tonghun

169

Separating strain from composition in unit cell parameter maps obtained from aberration corrected high resolution transmission electron microscopy imaging  

SciTech Connect (OSTI)

Based on the evaluation of lattice parameter maps in aberration corrected high resolution transmission electron microscopy images, we propose a simple method that allows quantifying the composition and disorder of a semiconductor alloy at the unit cell scale with high accuracy. This is realized by considering, next to the out-of-plane, also the in-plane lattice parameter component allowing to separate the chemical composition from the strain field. Considering only the out-of-plane lattice parameter component not only yields large deviations from the true local alloy content but also carries the risk of identifying false ordering phenomena like formations of chains or platelets. Our method is demonstrated on image simulations of relaxed supercells, as well as on experimental images of an In{sub 0.20}Ga{sub 0.80}N quantum well. Principally, our approach is applicable to all epitaxially strained compounds in the form of quantum wells, free standing islands, quantum dots, or wires.

Schulz, T.; Remmele, T.; Korytov, M.; Markurt, T.; Albrecht, M. [Leibniz-Institut für Kristallzüchtung, Max-Born-Straße 2, 12489 Berlin (Germany); Duff, A.; Lymperakis, L.; Neugebauer, J. [Max-Planck-Institut für Eisenforschung, Max-Planck-Straße 1, 40237 Düsseldorf (Germany); Chèze, C. [TopGaN Sp. z o.o., Sokolowska 29/37, 01-142 Warsaw (Poland); Skierbiszewski, C. [TopGaN Sp. z o.o., Sokolowska 29/37, 01-142 Warsaw (Poland); Institute of High Pressure Physics, Polish Academy of Sciences, Sokolowska 29/37, 01-142 Warsaw (Poland)

2014-01-21T23:59:59.000Z

170

Nova laser alignment control system  

SciTech Connect (OSTI)

Alignment of the Nova laser requires control of hundreds of optical components in the ten beam paths. Extensive application of computer technology makes daily alignment practical. The control system is designed in a manner which provides both centralized and local manual operator controls integrated with automatic closed loop alignment. Menudriven operator consoles using high resolution color graphics displays overlaid with transport touch panels allow laser personnel to interact efficiently with the computer system. Automatic alignment is accomplished by using image analysis techniques to determine beam references points from video images acquired along the laser chain. A major goal of the design is to contribute substantially to rapid experimental turnaround and consistent alignment results. This paper describes the computer-based control structure and the software methods developed for aligning this large laser system.

Van Arsdall, P.J.; Holloway, F.W.; McGuigan, D.L.; Shelton, R.T.

1984-03-29T23:59:59.000Z

171

HIGH-RESOLUTION HELIOSEISMIC IMAGING OF SUBSURFACE STRUCTURES AND FLOWS OF A SOLAR ACTIVE REGION OBSERVED BY HINODE  

SciTech Connect (OSTI)

We analyze a solar active region observed by the Hinode Ca II H line using the time-distance helioseismology technique, and infer wave-speed perturbation structures and flow fields beneath the active region with a high spatial resolution. The general subsurface wave-speed structure is similar to the previous results obtained from Solar and Heliospheric Observatory/Michelson Doppler Imager observations. The general subsurface flow structure is also similar, and the downward flows beneath the sunspot and the mass circulations around the sunspot are clearly resolved. Below the sunspot, some organized divergent flow cells are observed, and these structures may indicate the existence of mesoscale convective motions. Near the light bridge inside the sunspot, hotter plasma is found beneath, and flows divergent from this area are observed. The Hinode data also allow us to investigate potential uncertainties caused by the use of phase-speed filter for short travel distances. Comparing the measurements with and without the phase-speed filtering, we find out that inside the sunspot, mean acoustic travel times are in basic agreement, but the values are underestimated by a factor of 20%-40% inside the sunspot umbra for measurements with the filtering. The initial acoustic tomography results from Hinode show a great potential of using high-resolution observations for probing the internal structure and dynamics of sunspots.

Zhao Junwei; Kosovichev, Alexander G. [W. W. Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305-4085 (United States); Sekii, Takashi [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan)

2010-01-01T23:59:59.000Z

172

A black phosphorus photo-detector for multispectral, high-resolution imaging  

E-Print Network [OSTI]

Among the different 2-dimensional inorganic materials with their unique electronic and optical properties, the layered semiconductor black phosphorus is currently intensely researched for its potential applications in electronics and optoelectronics. The band gap energy of the bulk is 0.3eV, however, it increases with decreasing layer number; to 1.5eV for a single layer. Therefore, a multi-layer black phosphorus device should, in principle, allow photo-detection over a broad spectral range with sufficient sensitivity for practical imaging applications. Here, we map the active area of a multi-layer black phosphorus photo-detector and we characterize responsivity and gain of the device in the visible ({\\lambda}_{VIS}=532nm) as well as the near-infrared ({\\lambda}_{IR}=1550nm) spectral domain. By using the same device as a point-like detector at the two test wavelengths, we acquire diffraction-limited images of structures that exhibit sub-micron feature sizes. The results demonstrate the usefulness of two-dimens...

Engel, Michael; Avouris, Phaedon

2014-01-01T23:59:59.000Z

173

Multiparticle imaging technique for two-phase fluid flows using pulsed laser speckle velocimetry  

SciTech Connect (OSTI)

The practical use of Pulsed Laser Velocimetry (PLV) requires the use of fast, reliable computer-based methods for tracking numerous particles suspended in a fluid flow. Two methods for performing tracking are presented. One method tracks a particle through multiple sequential images (minimum of four required) by prediction and verification of particle displacement and direction. The other method, requiring only two sequential images uses a dynamic, binary, spatial, cross-correlation technique. The algorithms are tested on computer-generated synthetic data and experimental data which was obtained with traditional PLV methods. This allowed error analysis and testing of the algorithms on real engineering flows. A novel method is proposed which eliminates tedious, undersirable, manual, operator assistance in removing erroneous vectors. This method uses an iterative process involving an interpolated field produced from the most reliable vectors. Methods are developed to allow fast analysis and presentation of sets of PLV image data. Experimental investigation of a two-phase, horizontal, stratified, flow regime was performed to determine the interface drag force, and correspondingly, the drag coefficient. A horizontal, stratified flow test facility using water and air was constructed to allow interface shear measurements with PLV techniques. The experimentally obtained local drag measurements were compared with theoretical results given by conventional interfacial drag theory. Close agreement was shown when local conditions near the interface were similar to space-averaged conditions. However, theory based on macroscopic, space-averaged flow behavior was shown to give incorrect results if the local gas velocity near the interface as unstable, transient, and dissimilar from the average gas velocity through the test facility.

Hassan, T.A.

1992-12-01T23:59:59.000Z

174

arecibo high resolution: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

84 Using Moderate Resolution Imaging Spectrometer (MODIS) to calibrate advanced very high resolution radiometer Geosciences Websites Summary: Using Moderate Resolution Imaging...

175

High resolution, multiple-energy linear sweep detector for x-ray imaging  

DOE Patents [OSTI]

Apparatus is disclosed for generating plural electrical signals in a single scan in response to incident X-rays received from an object. Each electrical signal represents an image of the object at a different range of energies of the incident X-rays. The apparatus comprises a first X-ray detector, a second X-ray detector stacked upstream of the first X-ray detector, and an X-ray absorber stacked upstream of the first X-ray detector. The X-ray absorber provides an energy-dependent absorption of the incident X-rays before they are incident at the first X-ray detector, but provides no absorption of the incident X-rays before they are incident at the second X-ray detector. The first X-ray detector includes a linear array of first pixels, each of which produces an electrical output in response to the incident X-rays in a first range of energies. The first X-ray detector also includes a circuit that generates a first electrical signal in response to the electrical output of each of the first pixels. The second X-ray detector includes a linear array of second pixels, each of which produces an electrical output in response to the incident X-rays in a second range of energies, broader than the first range of energies. The second X-ray detector also includes a circuit that generates a second electrical signal in response to the electrical output of each of the second pixels. 12 figs.

Perez-Mendez, V.; Goodman, C.A.

1996-08-20T23:59:59.000Z

176

High resolution, multiple-energy linear sweep detector for x-ray imaging  

DOE Patents [OSTI]

Apparatus for generating plural electrical signals in a single scan in response to incident X-rays received from an object. Each electrical signal represents an image of the object at a different range of energies of the incident X-rays. The apparatus comprises a first X-ray detector, a second X-ray detector stacked upstream of the first X-ray detector, and an X-ray absorber stacked upstream of the first X-ray detector. The X-ray absorber provides an energy-dependent absorption of the incident X-rays before they are incident at the first X-ray detector, but provides no absorption of the incident X-rays before they are incident at the second X-ray detector. The first X-ray detector includes a linear array of first pixels, each of which produces an electrical output in response to the incident X-rays in a first range of energies. The first X-ray detector also includes a circuit that generates a first electrical signal in response to the electrical output of each of the first pixels. The second X-ray detector includes a linear array of second pixels, each of which produces an electrical output in response to the incident X-rays in a second range of energies, broader than the first range of energies. The second X-ray detector also includes a circuit that generates a second electrical signal in response to the electrical output of each of the second pixels.

Perez-Mendez, Victor (Berkeley, CA); Goodman, Claude A. (Kensington, CA)

1996-01-01T23:59:59.000Z

177

Infrared Scattering Scanning Near-Field Optical Microscopy Using An External Cavity Quantum Cascade Laser For Nanoscale Chemical Imaging And Spectroscopy of Explosive Residues  

SciTech Connect (OSTI)

Infrared scattering scanning near-field optical microscopy (s-SNOM) is an apertureless superfocusing technique that uses the antenna properties of a conducting atomic force microscope (AFM) tip to achieve infrared spatial resolution below the diffraction limit. The instrument can be used either in imaging mode, where a fixed wavelength light source is tuned to a molecular resonance and the AFM raster scans an image, or in spectroscopy mode where the AFM is held stationary over a feature of interest and the light frequency is varied to obtain a spectrum. In either case, a strong, stable, coherent infrared source is required. Here we demonstrate the integration of a broadly tunable external cavity quantum cascade laser (ECQCL) into an s-SNOM and use it to obtain infrared spectra of microcrystals of chemicals adsorbed onto gold substrates. Residues of the explosive compound tetryl was deposited onto gold substrates. s-SNOM experiments were performed in the 1260-1400 cm?1 tuning range of the ECQCL, corresponding to the NO2 symmetric stretch vibrational fingerprint region. Vibrational infrared spectra were collected on individual chemical domains with a collection area of *500nm2 and compared to ensemble averaged far-field reflection-absorption infrared spectroscopy (RAIRS) results.

Craig, Ian M.; Phillips, Mark C.; Taubman, Matthew S.; Josberger, Erik E.; Raschke, Markus Bernd

2013-02-04T23:59:59.000Z

178

Development of a high-frame-rate high-resolution particle image velocimetry system and applications to the characterization of synthetic jet actuators  

E-Print Network [OSTI]

to 3,000 frames per second and a maximum image resolution of 512 by 512 pixels. The performance of these systems was demonstrated by utilizing them to experimentally characterize the flowfield generated by a synthetic jet actuator, operating at a...

Gilarranz, Jose Luis

1998-01-01T23:59:59.000Z

179

Laser device  

DOE Patents [OSTI]

A laser device includes a target position, an optical component separated a distance J from the target position, and a laser energy source separated a distance H from the optical component, distance H being greater than distance J. A laser source manipulation mechanism exhibits a mechanical resolution of positioning the laser source. The mechanical resolution is less than a spatial resolution of laser energy at the target position as directed through the optical component. A vertical and a lateral index that intersect at an origin can be defined for the optical component. The manipulation mechanism can auto align laser aim through the origin during laser source motion. The laser source manipulation mechanism can include a mechanical index. The mechanical index can include a pivot point for laser source lateral motion and a reference point for laser source vertical motion. The target position can be located within an adverse environment including at least one of a high magnetic field, a vacuum system, a high pressure system, and a hazardous zone. The laser source and an electro-mechanical part of the manipulation mechanism can be located outside the adverse environment. The manipulation mechanism can include a Peaucellier linkage.

Scott, Jill R. (Idaho Falls, ID); Tremblay, Paul L. (Idaho Falls, ID)

2007-07-10T23:59:59.000Z

180

Mapping the Ionization State of Laser-Irradiated Ar Gas Jets With Multi-Wavelength Monochromatic X-Ray Imaging  

SciTech Connect (OSTI)

Two-dimensional monochromatic images of fast-electron stimulated Ar K{alpha} and He-{alpha} x-ray self-emission have recorded a time-integrated map of the extent of Ar{sup {approx}6+} and Ar{sup 16+} ions, respectively, within a high density (10{sup 20} cm{sup -3} atomic density) Ar plasma. This plasma was produced by irradiating a 2 mm wide clustering Ar gas jet with an ultra-high intensity (10{sup 19} W/cm{sup 2}, 200 fs) Ti:Sapphire laser operating at 800 nm. Spherically bent quartz crystals in the 200 (for K{alpha}) and 201 (for He-{alpha}) planes were used as near-normal incidence reflective x-ray optics. We see that a large (830 {micro}m long) region of plasma emits K{alpha} primarily along the laser axis, while the He-{alpha} emission is confined to smaller hot spot (230 {micro}m long) region that likely corresponds to the focal volume of the f/8 laser beam. X-ray spectra from a Bragg spectrometer operating in the von Hamos geometry, which images in one dimension, indicate that the centroids of the K{alpha} and He-{alpha} emission regions are separated by approximately 330 {micro}m along the laser axis.

Kugland, N L; Doppner, T; Kemp, A; Schaeffer, D; Glenzer, S H; Niemann, C

2010-04-08T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Visible Light Digital Camera --Up to 2.3MP resolution with LED lamps provides sharp images  

E-Print Network [OSTI]

electrical and industrial applications · Thumbnail Image Gallery -- Allows quick search of stored images Marker Function · Auto Hot/Cold spot marker function shows a spot within the area that automatically% of reading Image Storage (1GB micro SD card) 1000 Images 1000 Images 1000 Images Emissivity Table 0.1 to 1

Short, Daniel

182

High resolution neutron imaging of water in the polymer electrolyte membrane  

SciTech Connect (OSTI)

To achieve a deeper understanding of water transport and performance issues associated with water management, we have conducted in situ water examinations to help understand the effects of components and operation. High Frequency Resistance (HFR), AC Impedance and neutron radiography were used to measure water content in operating fuel cells under various operating conditions. Variables examined include: sub-freezing conditions, inlet relative humidities, cell temperature, current density and response transients, different flow field orientations and different component materials (membranes, GDLs and MEAs). Quantification of the water within the membrane was made by neutron radiography after equilibration to different humidified gases, during fuel cell operation and in hydrogen pump mode. The water content was evaluated in bare Nafion{reg_sign} membranes as well as in MEAs operated in both fuel cell and H{sub 2} pump mode. These in situ imaging results allow measurement of the water content and gradients in the PEFC membrane and relate the membrane water transport characteristics to the fuel cell operation and performance under disparate materials and operational combinations. Flow geometry makes a large impact on MEA water content. Higher membrane water with counter flow was measured compared with co-flow for sub-saturated inlet RH's. This correlates to lower HFR and higher performance compared with co-flow. Higher anode stoichiometry helps remove water which accumulates in the anode channels and GDL material. Cell orientation was measured to affect both the water content and cell performance. While membrane water content was measured to be similar regardless of orientation, cells with the cathode on top show flooding and loss of performance compared with similarly operated cells with the anode on top. Transient fuel cell current measurements show a large degree of hysteresis in terms of membrane hydration as measured by HFR. Current step transients from 0.01 A cm{sup -2} to 0.68 A cm{sup -2} consistently show PEM wetting occurring within 5 to 20 sec. Whereas the PEM drying response to the reverse step transient of 0.68 A cm{sup -2} to 0.01 A cm{sup -2}, takes several minutes. The observed faster wetting response is due to reaction water being produced in the cathode and back diffusing into the membrane. The slower PEM drying is due to the water slowly being removed out of the wetted GDLs. This rate of removal of water and hence the PEM hydration level was found to be influenced strongly by the PTFE loadings in the GDL substrate and Microporous layer (MPL). The drying of the membrane is influenced by both the anode and cathode GDL PTFE loadings. Lower PTFE loading in the anode GDL leads to better membrane hydration probably due to the easier incorporation of water from the anode GDL into the membrane. Similarly a lower PTFE loading in the cathode GDL also results in better membrane hydration probably due to the better water retention properties (less hydrophobic) of this GDL. Fuel cells operated isothermal at sub-freezing temperatures show gradual cell performance decay over time and eventually drops to zero. AC impedance analysis indicates that losses are initially due to increasing charge transfer resistance. After time, the rate of decay accelerates rapidly due to mass transport limitations. High frequency resistance also increases over time and is a function of the initial membrane water content. These results indicate that catalyst layer ice formation is influenced strongly by the MEA and is responsible for the long-term degradation of fuel cells operated at sub-freezing temperatures. Water distribution measurements indicate that ice may be fonning mainly in the GDLs at -10 C but are concentrated in the catalyst layer at -20 C.

Spernjak, Dusan [Los Alamos National Laboratory; Mukundan, Rangachary [Los Alamos National Laboratory; Borup, Rodney L [Los Alamos National Laboratory; Spendelow, Jacob S [Los Alamos National Laboratory; Davey, John [Los Alamos National Laboratory; Fairweather, Joseph [Los Alamos National Laboratory; Mukherjee, Partha [ORNL

2010-01-01T23:59:59.000Z

183

Two-dimensional imaging of gas-to-particle transition in flames by laser-induced nanoplasmas  

SciTech Connect (OSTI)

Two-dimensional imaging of gas/particle phase transition of metal oxides in their native high-temperature flow conditions, using laser-driven localized nanoplasmas, was obtained by utilizing the gap between the excitation energies of the gas and particle phases such that only the Ti atoms in the particle phase were selectively excited without detectable Bremsstrahlung background. These in situ images of the particle phase Ti distribution allow the quantitative visualization of the transition of the gas precursors to the nanoparticle phase across the flame sheet as well as diffusion of the particle concentration in the post-flame zone.

Zhang, Yiyang [Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Thermal Engineering, Tsinghua University, Beijing 100084 (China); Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Li, Shuiqing, E-mail: lishuiqing@tsinghua.edu.cn; Ren, Yihua; Yao, Qiang [Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Thermal Engineering, Tsinghua University, Beijing 100084 (China); Law, Chung K. [Center for Combustion Energy, Tsinghua University, Beijing 100084 (China); Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, New Jersey 08544-5263 (United States)

2014-01-13T23:59:59.000Z

184

Improved spectral data unfolding for radiochromic film imaging spectroscopy of laser-accelerated proton beams  

SciTech Connect (OSTI)

An improved method to unfold the space-resolved proton energy distribution function of laser-accelerated proton beams using a layered, radiochromic film (RCF) detector stack has been developed. The method takes into account the reduced RCF response near the Bragg peak due to a high linear energy transfer (LET). This LET dependence of the active RCF layer has been measured, and published data have been re-interpreted to find a nonlinear saturation scaling of the RCF response with stopping power. Accounting for the LET effect increased the integrated particle yield by 25% after data unfolding. An iterative, analytical, space-resolved deconvolution of the RCF response functions from the measured dose was developed that does not rely on fitting. After the particle number unfold, three-dimensional interpolation is performed to determine the spatial proton beam distribution for proton energies in-between the RCF data points. Here, image morphing has been implemented as a novel interpolation method that takes into account the energy-dependent, changing beam topology.

Schollmeier, M.; Geissel, M.; Sefkow, A. B. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States)] [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States); Flippo, K. A. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)] [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

2014-04-15T23:59:59.000Z

185

Robotic Laser-Adaptive-Optics Imaging of 715 Kepler Exoplanet Candidates using Robo-AO  

E-Print Network [OSTI]

The Robo-AO Kepler Planetary Candidate Survey is designed to observe every Kepler planet candidate host star with laser adaptive optics imaging to search for blended nearby stars, which may be physically associated companions and/or responsible for transit false positives. In this paper we present the results from the 2012 observing season, searching for stars close to 715 representative Kepler planet candidate hosts. We find 53 companions, 44 of which are new discoveries. We detail the Robo-AO survey data reduction methods including a method of using the large ensemble of target observations as mutual point-spread-function references, along with a new automated companion-detection algorithm designed for large adaptive optics surveys. Our survey is sensitive to objects from 0.15" to 2.5" separation, with contrast ratios up to delta-m~6. We measure an overall nearby-star-probability for Kepler planet candidates of 7.4% +/- 1.0%, and calculate the effects of each detected nearby star on the Kepler-measured plan...

Law, Nicholas M; Baranec, Christoph; Riddle, Reed; Ravichandran, Ganesh; Ziegler, Carl; Johnson, John Asher; Tendulkar, Shriharsh P; Bui, Khanh; Burse, Mahesh P; Das, H K; Dekany, Richard G; Kulkarni, Shrinivas; Punnadi, Sujit; Ramaprakash, A N

2013-01-01T23:59:59.000Z

186

Performance predictions for a laser intensified thermal beam for use in high resolution Focused Ion Beam instruments  

E-Print Network [OSTI]

Photo-ionization of a laser-cooled and compressed atomic beam from a high-flux thermal source can be used to create a high-brightness ion beam for use in Focus Ion Beam (FIB) instruments. Here we show using calculations and Doppler cooling simulations that an atomic rubidium beam with a brightness of $2.1 \\times 10^7 A/(m^2\\,sr\\,eV)$ at a current of 1 nA can be created using a compact 5 cm long 2D magneto-optical compressor which is more than an order of magnitude better than the current state of the art Liquid Metal Ion Source.

Wouters, S H W; Notermans, R P M J W; Debernardi, N; Mutsaers, P H A; Luiten, O J; Vredenbregt, E J D

2014-01-01T23:59:59.000Z

187

Three-dimensional molecular imaging by infrared laser ablation electrospray ionization mass spectrometry  

DOE Patents [OSTI]

The field of the invention is atmospheric pressure mass spectrometry (MS), and more specifically a process and apparatus which combine infrared laser ablation with electrospray ionization (ESI).

Vertes, Akos (Reston, VA); Nemes, Peter (Silver Spring, MD)

2011-06-21T23:59:59.000Z

188

Laser ablation electrospray ionization (LAESI) for atmospheric pressure, In vivo, and imaging mass spectrometry  

DOE Patents [OSTI]

The field of the invention is atmospheric pressure mass spectrometry (MS), and more specifically a process and apparatus which combine infrared laser ablation (LA) with electrospray ionization (ESI).

Vertes, Akos (Reston, VA); Nemes, Peter (Silver Spring, MD)

2011-11-29T23:59:59.000Z

189

Laser ablation electrospray ionization (LAESI) for atmospheric pressure, in vivo, and imaging mass spectrometry  

DOE Patents [OSTI]

The field of the invention is atmospheric pressure mass spectrometry (MS), and more specifically a process and apparatus which combine infrared laser ablation with electrospray ionization (ESI).

Vertes, Akos; Nemes, Peter

2014-08-19T23:59:59.000Z

190

Laser ablation electrospray ionization (LAESI) for atmospheric pressure, in vivo, and imaging mass spectrometry  

DOE Patents [OSTI]

The field of the invention is atmospheric pressure mass spectrometry (MS), and more specifically a process and apparatus which combine infrared laser ablation with electrospray ionization (ESI).

Vertes, Akos; Nemes, Peter

2013-07-16T23:59:59.000Z

191

Three-dimensional molecular imaging by infrared laser ablation electrospray ionization mass spectrometry  

DOE Patents [OSTI]

The field of the invention is atmospheric pressure mass spectrometry (MS), and more specifically a process and apparatus which combine infrared laser ablation with electrospray ionization (ESI).

Vertes, Akos; Nemes, Peter

2013-07-16T23:59:59.000Z

192

Three-dimensional molecular imaging by infrared laser ablation electrospray ionization mass spectrometry  

DOE Patents [OSTI]

The field of the invention is atmospheric pressure mass spectrometry (MS), and more specifically a process and apparatus which combine infrared laser ablation with electrospray ionization (ESI).

Vertes, Akos; Nemes, Peter

2012-10-30T23:59:59.000Z

193

Optical-resolution photoacoustic imaging through thick tissue with a thin capillary as a dual optical-in acoustic-out waveguide  

E-Print Network [OSTI]

We demonstrate the ability to guide high-frequency photoacoustic waves through thick tissue with a water-filled silica-capillary (150 \\mu m inner diameter and 30 mm long). An optical-resolution photoacoustic image of a 30 \\mu m diameter absorbing nylon thread was obtained by guiding the acoustic waves in the capillary through a 3 cm thick fat layer. The transmission loss through the capillary was about -20 dB, much lower than the -120 dB acoustic attenuation through the fat layer. The overwhelming acoustic attenuation of high-frequency acoustic waves by biological tissue can therefore be avoided by the use of a small footprint capillary acoustic waveguide for remote detection. We finally demonstrate that the capillary can be used as a dual optical-in acoustic-out waveguide, paving the way for the development of minimally invasive optical-resolution photoacoustic endoscopes free of any acoustic or optical elements at their imaging tip.

Simandoux, Olivier; Gateau, Jerome; Huignard, Jean-Pierre; Moser, Christophe; Psaltis, Demetri; Bossy, Emmanuel

2015-01-01T23:59:59.000Z

194

A new generic method for the semi-automatic extraction of river and road networks in low and mid-resolution satellite images  

SciTech Connect (OSTI)

This paper addresses the problem of semi-automatic extraction of road or hydrographic networks in satellite images. For that purpose, we propose an approach combining concepts arising from mathematical morphology and hydrology. The method exploits both geometrical and topological characteristics of rivers/roads and their tributaries in order to reconstruct the complete networks. It assumes that the images satisfy the following two general assumptions, which are the minimum conditions for a road/river network to be identifiable and are usually verified in low- to mid-resolution satellite images: (i) visual constraint: most pixels composing the network have similar spectral signature that is distinguishable from most of the surrounding areas; (ii) geometric constraint: a line is a region that is relatively long and narrow, compared with other objects in the image. While this approach fully exploits local (roads/rivers are modeled as elongated regions with a smooth spectral signature in the image and a maximum width) and global (they are structured like a tree) characteristics of the networks, further directional information about the image structures is incorporated. Namely, an appropriate anisotropic metric is designed by using both the characteristic features of the target network and the eigen-decomposition of the gradient structure tensor of the image. Following, the geodesic propagation from a given network seed with this metric is combined with hydrological operators for overland flow simulation to extract the paths which contain most line evidence and identify them with the target network.

Grazzini, Jacopo [Los Alamos National Laboratory; Dillard, Scott [PNNL; Soille, Pierre [EC JRC

2010-10-21T23:59:59.000Z

195

Design of a near-field coded aperture cameras for high-resolution medical and industrial gamma-ray imaging  

E-Print Network [OSTI]

Coded Aperture Imaging is a technique originally developed for X-ray astronomy, where typical imaging problems are characterized by far-field geometry and an object made of point sources distributed over a mainly dark ...

Accorsi, Roberto, 1971-

2001-01-01T23:59:59.000Z

196

Active hyperspectral imaging using a quantum cascade laser (QCL) array and digital-pixel focal  

E-Print Network [OSTI]

, D. L. Sivco, and A. Y. Cho, "Quantum cascade lasers," Phys. Today 55(5), 34 (2002). 13. Daylight Solutions, Inc., www.daylightsolutions.com; Block Engineering LLC, www.blockeng.com. 14. B. G. Lee, M. A

Capasso, Federico

197

Investigation of relativistic intensity laser generated hot electron dynamics via copper K{sub ?} imaging and proton acceleration  

SciTech Connect (OSTI)

Simultaneous experimental measurements of copper K{sub ?} imaging and the maximum target normal sheath acceleration proton energies from the rear target surface are compared for various target thicknesses. For the T-cubed laser (?4 J, 400 fs) at an intensity of ?2 × 10{sup 19} W cm{sup ?2}, the hot electron divergence is determined to be ?{sub HWHM}?22{sup °} using a K{sub ?} imaging diagnostic. The maximum proton energies are measured to follow the expected reduction with increasing target thickness. Numerical modeling produces copper K{sub ?} trends for both signal level and electron beam divergence that are in good agreement with the experiment. A geometric model describing the electron beam divergence reproduces the maximum proton energy trends observed from the experiment and the fast electron density and the peak electric field observed in the numerical modeling.

Willingale, L.; Thomas, A. G. R.; Maksimchuk, A; Krushelnick, K. [Center for Ultrafast Optical Science, University of Michigan, 2200 Bonisteel Boulevard, Ann Arbor, Michigan 48109 (United States)] [Center for Ultrafast Optical Science, University of Michigan, 2200 Bonisteel Boulevard, Ann Arbor, Michigan 48109 (United States); Morace, A. [University of California-San Diego, La Jolla, California 92093 (United States) [University of California-San Diego, La Jolla, California 92093 (United States); Università di Milano-Biocca, Piazza della Scienza 3, 20126 Milano (Italy); Bartal, T.; Kim, J.; Beg, F. N. [University of California-San Diego, La Jolla, California 92093 (United States)] [University of California-San Diego, La Jolla, California 92093 (United States); Stephens, R. B.; Wei, M. S. [General Atomics, San Diego, California 92121 (United States)] [General Atomics, San Diego, California 92121 (United States)

2013-12-15T23:59:59.000Z

198

High-resolution wave-theory-based ultrasound reflection imaging using the split-step fourier and globally optimized fourier finite-difference methods  

DOE Patents [OSTI]

Methods for enhancing ultrasonic reflection imaging are taught utilizing a split-step Fourier propagator in which the reconstruction is based on recursive inward continuation of ultrasonic wavefields in the frequency-space and frequency-wave number domains. The inward continuation within each extrapolation interval consists of two steps. In the first step, a phase-shift term is applied to the data in the frequency-wave number domain for propagation in a reference medium. The second step consists of applying another phase-shift term to data in the frequency-space domain to approximately compensate for ultrasonic scattering effects of heterogeneities within the tissue being imaged (e.g., breast tissue). Results from various data input to the method indicate significant improvements are provided in both image quality and resolution.

Huang, Lianjie

2013-10-29T23:59:59.000Z

199

Development of a High Resolution X-Ray Imaging Crystal Spectrometer for Measurement of Ion-Temperature and Rotation-Velocity Profiles in Fusion Energy Research Plasmas  

SciTech Connect (OSTI)

A new imaging high resolution x-ray crystal spectrometer (XCS) has been developed to measure continuous profiles of ion temperature and rotation velocity in fusion plasmas. Following proof-of-principle tests on the Alcator C-Mod tokamak and the NSTX spherical tokamak, and successful testing of a new silicon, pixilated detector with 1MHz count rate capability per pixel, an imaging XCS is being designed to measure full profiles of Ti and v? on C-Mod. The imaging XCS design has also been adopted for ITER. Ion-temperature uncertainty and minimum measurable rotation velocity are calculated for the C-Mod spectrometer. The affects of x-ray and nuclear-radiation background on the measurement uncertainties are calculated to predict performance on ITER.

Hill, K W; Broennimann, Ch; Eikenberry, E F; Ince-Cushman, A; Lee, S G; Rice, J E; Scott, S; Barnsley, R

2008-02-27T23:59:59.000Z

200

BazookaSPECT: A Low-Cost Approach to High-Resolution, Single-Photon Imaging Using Columnar Scintillators and Image Intensifiers  

E-Print Network [OSTI]

-photon counting gamma-ray detector based on an image intensifier optically coupled to a low-cost CCD. Typically and allowing for a customizable imaging system. Operating in photon-counting mode, individual gamma-ray functioning as a gamma-ray microscope, (b) white-light microscope image of four 111 In oxine source beads, (c

Arizona, University of

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

High-resolution shear-wave reflection profiling to image offset in unconsolidated near-surface sediments  

E-Print Network [OSTI]

S-wave reflection profiling has many theoretical advantages, when compared to P-wave profiling, such as high-resolution potential, greater sensitivities to lithologic changes and insensitivity to the water table and pore ...

Bailey, Bevin

2014-05-31T23:59:59.000Z

202

Astron. Nachr./AN 32X (2002) X, XXXXXX Imaging Magnetographs for High-Resolution Solar Observations in  

E-Print Network [OSTI]

Magnetograph (VIM) is basically a twin of IRIM for observations in the wavelength range from 550 nm to 700 nm goals of VIM and IRIM are high temporal and spatial resolution observations while maintaining moderate

203

Seeing inside chips and cells: High-resolution subsurface imaging of integrated circuits, quantum dots and subcellular structures  

E-Print Network [OSTI]

techniques for IC failure analysis ­ solid immersion lens microscopy and solid immersion lens thermography improvement from >5µm to a resolution of 1.3µm, representing the best subsurface thermography to date

204

High-resolution shear-wave reflection profiling to image offset in unconsolidated near-surface sediments.  

E-Print Network [OSTI]

??S-wave reflection profiling has many theoretical advantages, when compared to P-wave profiling, such as high-resolution potential, greater sensitivities to lithologic changes and insensitivity to the… (more)

Bailey, Bevin

2014-01-01T23:59:59.000Z

205

TESTING THE HYPOTHESIS THAT METHANOL MASER RINGS TRACE CIRCUMSTELLAR DISKS: HIGH-RESOLUTION NEAR-INFRARED AND MID-INFRARED IMAGING  

SciTech Connect (OSTI)

Milliarcsecond very long baseline interferometry maps of regions containing 6.7 GHz methanol maser emission have lead to the recent discovery of ring-like distributions of maser spots and the plausible hypothesis that they may be tracing circumstellar disks around forming high-mass stars. We aimed to test this hypothesis by imaging these regions in the near- and mid-infrared at high spatial resolution and compare the observed emission to the expected infrared morphologies as inferred from the geometries of the maser rings. In the near-infrared we used the Gemini North adaptive optics system of ALTAIR/NIRI, while in the mid-infrared we used the combination of the Gemini South instrument T-ReCS and super-resolution techniques. Resultant images had a resolution of {approx}150 mas in both the near-infrared and mid-infrared. We discuss the expected distribution of circumstellar material around young and massive accreting (proto)stars and what infrared emission geometries would be expected for the different maser ring orientations under the assumption that the masers are coming from within circumstellar disks. Based upon the observed infrared emission geometries for the four targets in our sample and the results of spectral energy distribution modeling of the massive young stellar objects associated with the maser rings, we do not find compelling evidence in support of the hypothesis that methanol masers rings reside in circumstellar disks.

De Buizer, James M. [Stratospheric Observatory for Infrared Astronomy-USRA, NASA Ames Research Center, MS N232-12, Moffett Field, CA 94035 (United States); Bartkiewicz, Anna; Szymczak, Marian, E-mail: jdebuizer@sofia.usra.edu [Torun Centre for Astronomy, Nicolaus Copernicus University, Gagarina 11, 87-100 Torun (Poland)

2012-08-01T23:59:59.000Z

206

Imaging the ultrafast Kerr effect, free carrier generation, relaxation and ablation dynamics of Lithium Niobate irradiated with femtosecond laser pulses  

SciTech Connect (OSTI)

The interaction of high-power single 130 femtosecond (fs) laser pulses with the surface of Lithium Niobate is experimentally investigated in this work. The use of fs-resolution time-resolved microscopy allows us to separately observe the instantaneous optical Kerr effect induced by the pulse and the generation of a free electron plasma. The maximum electron density is reached 550?fs after the peak of the Kerr effect, confirming the presence of a delayed carrier generation mechanism. We have also observed the appearance of transient Newton rings during the ablation process, related to optical interference of the probe beam reflected at the front and back surface of the ablating layer. Finally, we have analyzed the dynamics of the photorefractive effect on a much longer time scale by measuring the evolution of the transmittance of the irradiated area for different fluences below the ablation threshold.

Garcia-Lechuga, Mario, E-mail: mario@io.cfmac.csic.es; Siegel, Jan, E-mail: j.siegel@io.cfmac.csic.es; Hernandez-Rueda, Javier; Solis, Javier [Laser Processing Group, Instituto de Optica, CSIC, Serrano 121, 28006 Madrid (Spain)

2014-09-21T23:59:59.000Z

207

Design Parameters and Objectives of a High-­Resolution X-­ray Imaging Crystal Spectrometer for the Large Helical Device (LHD)  

SciTech Connect (OSTI)

A high-resolution X-ray imaging crystal spectrometer, whose instrumental concept was thoroughly tested on NSTX and Alcator C-Mod, is presently being designed for LHD. The instrument will record spatially resolved spectra of helium-like Ar16+ and provide ion temperature profiles with spatial and temporal resolutions of 1 cm and > 10 ms which are obtained by a tomographic inversion of the spectral data, using the stellarator equilibrium reconstruction codes, STELLOPT and PIES. Since the spectrometer will be equipped with radiation hardened, high count rate, PILATUS detectors,, it is expected to be operational for all experimental conditions on LHD, which include plasmas of high density and plasmas with auxiliary RF and neutral beam heating. The special design features required by the magnetic field structure at LHD will be described.

Bitter, M; Gates, D; Neilson, H; Reiman, A; Roquemore, A L; Morita, S; Goto, M; Yamada, H; Rice, J

2010-05-19T23:59:59.000Z

208

Imaging single cells in a beam of live cyanobacteria with an X-ray laser  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

This entry contains ten diffraction patterns, and reconstructions images, of individual living Cyanobium gracile cells, imaged using 517 eV X-rays from the LCLS XFEL. The Hawk software package was used for phasing. The Uppsala aerosol injector was used for sample injection, assuring very low noise levels. The cells come from various stages of the cell cycle, and were imaged in random orientations.

Schot, Gijs, vander

209

HIGH-RESOLUTION INFRARED IMAGING AND SPECTROSCOPY OF THE Z CANIS MAJORIS SYSTEM DURING QUIESCENCE AND OUTBURST  

SciTech Connect (OSTI)

We present adaptive optics photometry and spectra in the JHKL bands along with high spectral resolution K-band spectroscopy for each component of the Z Canis Majoris system. Our high angular resolution photometry of this very young ({approx}<1 Myr) binary, comprised of an FU Ori object and a Herbig Ae/Be star, was gathered shortly after the 2008 outburst while our high-resolution spectroscopy was gathered during a quiescent phase. Our photometry conclusively determines that the outburst was due solely to the embedded Herbig Ae/Be member, supporting results from earlier works, and that the optically visible FU Ori component decreased slightly ({approx}30%) in luminosity during the same period, consistent with previous works on the variability of FU Ori type systems. Further, our high-resolution K-band spectra definitively demonstrate that the 2.294 {mu}m CO absorption feature seen in composite spectra of the system is due solely to the FU Ori component, while a prominent CO emission feature at the same wavelength, long suspected to be associated with the innermost regions of a circumstellar accretion disk, can be assigned to the Herbig Ae/Be member. These findings clarify previous analyses of the origin of the CO emission in this complex system.

Hinkley, Sasha; Hillenbrand, Lynne; Crepp, Justin R. [Department of Astronomy, California Institute of Technology, 1200 E. California Blvd, MC 249-17, Pasadena, CA 91125 (United States); Oppenheimer, Ben R.; Zimmerman, Neil; Brenner, Douglas [Astrophysics Department, American Museum of Natural History, Central Park West at 79th Street, New York, NY 10024 (United States); Rice, Emily L. [Department of Engineering Science and Physics, College of Staten Island, City University of New York, 2800 Victory Bvld, Staten Island, NY 10314 (United States); Pueyo, Laurent [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Vasisht, Gautam; Roberts, Jennifer E.; Roberts, Lewis C. Jr.; Burruss, Rick; Wallace, J. Kent; Cady, Eric; Zhai, Chengxing [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Dr., Pasadena, CA 91109 (United States); Kraus, Adam L. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA, 02138 (United States); Ireland, Michael J. [Department of Physics and Astronomy, Macquarie University, New South Wales, NSW 2109 (Australia); Beichman, Charles [NASA Exoplanet Science Institute, California Institute of Technology, Pasadena, CA 91125 (United States); Dekany, Richard [Caltech Optical Observatories, California Institute of Technology, Pasadena, CA 91125 (United States); Parry, Ian R. [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom); and others

2013-01-20T23:59:59.000Z

210

Zoomed Functional Imaging in the Human Brain at 7 Tesla with Simultaneous High Spatial and High Temporal Resolution  

E-Print Network [OSTI]

Zoomed Functional Imaging in the Human Brain at 7 Tesla with Simultaneous High Spatial and High and is mainly limited by sensitivity. Here, signal-to-noise gains at high magnetic fields (7 Tesla

211

High resolution biomedical imaging system with direct detection of x-rays via a charge coupled device  

DOE Patents [OSTI]

An imaging system is provided for direct detection of x-rays from an irradiated biological tissue. The imaging system includes an energy source for emitting x-rays toward the biological tissue and a charge coupled device (CCD) located immediately adjacent the biological tissue and arranged transverse to the direction of irradiation along which the x-rays travel. The CCD directly receives and detects the x-rays after passing through the biological tissue. The CCD is divided into a matrix of cells, each of which individually stores a count of x-rays directly detected by the cell. The imaging system further includes a pattern generator electrically coupled to the CCD for reading a count from each cell. A display device is provided for displaying an image representative of the count read by the pattern generator from the cells of the CCD. 13 figs.

Atac, M.; McKay, T.A.

1998-04-21T23:59:59.000Z

212

High resolution biomedical imaging system with direct detection of x-rays via a charge coupled device  

DOE Patents [OSTI]

An imaging system is provided for direct detection of x-rays from an irradiated biological tissue. The imaging system includes an energy source for emitting x-rays toward the biological tissue and a charge coupled device (CCD) located immediately adjacent the biological tissue and arranged transverse to the direction of irradiation along which the x-rays travel. The CCD directly receives and detects the x-rays after passing through the biological tissue. The CCD is divided into a matrix of cells, each of which individually stores a count of x-rays directly detected by the cell. The imaging system further includes a pattern generator electrically coupled to the CCD for reading a count from each cell. A display device is provided for displaying an image representative of the count read by the pattern generator from the cells of the CCD.

Atac, Muzaffer (Wheaton, IL); McKay, Timothy A. (Ann Arbor, MI)

1998-01-01T23:59:59.000Z

213

Nondestructive 3D confocal laser imaging with deconvolution of seven whole stardust tracks with complementary XRF and quantitative analysis  

SciTech Connect (OSTI)

We present a nondestructive 3D system for analysis of whole Stardust tracks, using a combination of Laser Confocal Scanning Microscopy and synchrotron XRF. 3D deconvolution is used for optical corrections, and results of quantitative analyses of several tracks are presented. The Stardust mission to comet Wild 2 trapped many cometary and ISM particles in aerogel, leaving behind 'tracks' of melted silica aerogel on both sides of the collector. Collected particles and their tracks range in size from submicron to millimeter scale. Interstellar dust collected on the obverse of the aerogel collector is thought to have an average track length of {approx}15 {micro}m. It has been our goal to perform a total non-destructive 3D textural and XRF chemical analysis on both types of tracks. To that end, we use a combination of Laser Confocal Scanning Microscopy (LCSM) and X Ray Florescence (XRF) spectrometry. Utilized properly, the combination of 3D optical data and chemical data provides total nondestructive characterization of full tracks, prior to flattening or other destructive analysis methods. Our LCSM techniques allow imaging at 0.075 {micro}m/pixel, without the use of oil-based lenses. A full textural analysis on track No.82 is presented here as well as analysis of 6 additional tracks contained within 3 keystones (No.128, No.129 and No.140). We present a method of removing the axial distortion inherent in LCSM images, by means of a computational 3D Deconvolution algorithm, and present some preliminary experiments with computed point spread functions. The combination of 3D LCSM data and XRF data provides invaluable information, while preserving the integrity of the samples for further analysis. It is imperative that these samples, the first extraterrestrial solids returned since the Apollo era, be fully mapped nondestructively in 3D, to preserve the maximum amount of information prior to other, destructive analysis.

Greenberg, M.; Ebel, D.S. (AMNH)

2009-03-19T23:59:59.000Z

214

Imaging the foveal cone mosaic with a MEMS-based adaptive optics scanning laser ophthalmoscope  

E-Print Network [OSTI]

In: Porter J (ed), Adaptive optics for vision science:In: Black A (ed), Optics. Reading, MA: Addison-Wesley; 113.Optical Society of America a-Optics Image Science and Vision

Li, Yiang

2010-01-01T23:59:59.000Z

215

EUREM 12, Brno, Czech Republic, July 9-14, 2000 I 159 Super Resolution Imaging of Complex Metal Oxides  

E-Print Network [OSTI]

rather than the image intensity that is recorded by conventional HREM. In this paper, restorations that have been investigated are Nb16W18O94, which consists of pentagonal columns of metal cations projected, samples were prepared by crushing and dispersion of the raw material onto a holey carbon support film

Dunin-Borkowski, Rafal E.

216

Visual Comfort Analysis of Innovative Interior and Exterior Shading Systems for Commercial Buildings using High Resolution Luminance Images  

SciTech Connect (OSTI)

The objective of this study was to explore how calibrated high dynamic range (HDR) images (luminance maps) acquired in real world daylit environments can be used to characterize, evaluate, and compare visual comfort conditions of innovative facade shading and light-redirecting systems. Detailed (1536 x 1536 pixel) luminance maps were time-lapse acquired from two view positions in an unoccupied full scale testbed facility. These maps were analyzed using existing visual comfort metrics to quantify how innovative interior and exterior shading systems compare to conventional systems under real sun and sky conditions over a solstice-to-solstice test interval. The results provide a case study in the challenges and potential of methods of visualizing, evaluating and summarizing daily and seasonal variation of visual comfort conditions computed from large sets of image data.

Konis, Kyle; Lee, Eleanor; Clear, Robert

2011-01-11T23:59:59.000Z

217

Multiparticle imaging technique for two-phase fluid flows using pulsed laser speckle velocimetry. Final report, September 1988--November 1992  

SciTech Connect (OSTI)

The practical use of Pulsed Laser Velocimetry (PLV) requires the use of fast, reliable computer-based methods for tracking numerous particles suspended in a fluid flow. Two methods for performing tracking are presented. One method tracks a particle through multiple sequential images (minimum of four required) by prediction and verification of particle displacement and direction. The other method, requiring only two sequential images uses a dynamic, binary, spatial, cross-correlation technique. The algorithms are tested on computer-generated synthetic data and experimental data which was obtained with traditional PLV methods. This allowed error analysis and testing of the algorithms on real engineering flows. A novel method is proposed which eliminates tedious, undersirable, manual, operator assistance in removing erroneous vectors. This method uses an iterative process involving an interpolated field produced from the most reliable vectors. Methods are developed to allow fast analysis and presentation of sets of PLV image data. Experimental investigation of a two-phase, horizontal, stratified, flow regime was performed to determine the interface drag force, and correspondingly, the drag coefficient. A horizontal, stratified flow test facility using water and air was constructed to allow interface shear measurements with PLV techniques. The experimentally obtained local drag measurements were compared with theoretical results given by conventional interfacial drag theory. Close agreement was shown when local conditions near the interface were similar to space-averaged conditions. However, theory based on macroscopic, space-averaged flow behavior was shown to give incorrect results if the local gas velocity near the interface as unstable, transient, and dissimilar from the average gas velocity through the test facility.

Hassan, T.A.

1992-12-01T23:59:59.000Z

218

International Journal of Mass Spectrometry 260 (2007) 222–236 Extended data analysis strategies for high resolution imaging MS: New methods to deal with extremely large image hyperspectral datasets  

E-Print Network [OSTI]

The large size of the hyperspectral datasets that are produced with modern mass spectrometric imaging techniques makes it difficult to analyze the results. Unsupervised statistical techniques are needed to extract relevant information from these datasets and reduce the data into a surveyable overview. Multivariate statistics are commonly used for this purpose. Computational power and computer memory limit the resolution at which the datasets can be analyzed with these techniques. We introduce the use of a data format capable of efficiently storing sparse datasets for multivariate analysis. This format is more memory-efficient and therefore it increases the possible resolution together with a decrease of computation time. Three multivariate techniques are compared for both sparse-type data and non-sparse data acquired in two different imaging ToF-SIMS experiments and one LDI-ToF imaging experiment. There is no significant qualitative difference in the use of different data formats for the same multivariate algorithms. All evaluated multivariate techniques could be applied on both SIMS and the LDI imaging datasets. Principal component analysis is shown to be the fastest choice; however a small increase of computation time using a VARIMAX optimization increases the decomposition quality significantly. PARAFAC analysis is shown to be very effective in separating different chemical components but the calculations take a significant amount of time, limiting its use as a routine technique. An effective visualization of the results of the multivariate analysis is as important for the analyst as the computational issues. For this reason, a new technique for visualization is presented, combining both spectral loadings and spatial

Leendert A. Klerk A; Er Broersen B; Ian W. Fletcher C

2006-01-01T23:59:59.000Z

219

High Resolution Imaging of the Anomalous Flux-Ratio Gravitational Lens System CLASS B2045+265: Dark Or Luminous Satellites?  

SciTech Connect (OSTI)

The existence of flux-ratio anomalies between fold and cusp images in galaxy-scale strong-lens systems has led to an interpretation based on the presence of a high mass-fraction of cold-dark-matter (CDM) substructures around galaxies, as predicted by numerical N-body simulations. These substructures can cause large perturbations of the image magnifications, leading to changes in the image flux ratios. The flux-ratio anomaly is particularly evident in the radio-loud quadruple gravitational lens system CLASS B2045+265. In this paper, new high-resolution radio, optical, and infrared imaging of B2045+265 is presented which sheds more light on this anomaly and its possible causes. First, deep Very Long Baseline Array observations show very compact images, possibly with a hint of a jet, but with no evidence for differential scattering or scatter broadening. Hence, the flux-ratio anomaly is unlikely to be caused by refractive scattering in either the Milky Way or the lens galaxy. Second, optical and infrared observations with the Hubble Space Telescope and through Adaptive-Optics imaging with the W. M. Keck Telescope, show a previously undiscovered object--interpreted as a (tidally disrupted) dwarf satellite based on its colors and slight extension--between the main lens galaxy and the three anomalous flux-ratio images. Third, color variations in the early-type lens galaxy indicate recent star-formation, possibly the result of secondary infall of gas-rich satellites. A population of young galaxies around the lens system could explain the previously discovered strong [O II] emission. However, spiral structure and/or normal star formation in the lens galaxy cannot be excluded. In light of these new data, we propose a lens model for the system, including the observed dwarf satellite, which reproduces all positional and flux-ratio constraints, without the need for additional CDM substructure. Although the model is peculiar in that the dwarf galaxy must be highly flattened, the model is very similar to recently proposed mass models based on high-order multipole expansions.

McKean, J.P.; Koopmans, L.V.E.; Flack, C.E.; Fassnacht, C.D.; Thompson, D.; Matthews, K.; Blandford, R.D.; Readhead, A.C.S.; Soifer, B.T.; /UC, Davis /Bonn, Max Planck

2006-11-10T23:59:59.000Z

220

Convective flow measurements in a heated cavity using pulsed laser velocimetry with digital image processing  

E-Print Network [OSTI]

. This is essentially the trapezoidal sheet shown in figure 4. The thickness of the beam remains on the order of 1-1. 5 13 x-v plane z-y plane First Lens Focal Point Second Lens Third Lens Fig. 4. Laser light passing through a trio of piano-convex cylindrical...2 U3 v1 v2 3 u4 u5 u7 u8 u6 u9 v4 v 5 v7 v8 Figure 24. Pixel positions in relation to vector components. Expressing equation (15) spatially, where uij and vij are gray level values ranging from 0 to 255 at position i and j of each region...

Chavez, Hector Luis

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Single particle microscopy with nanometer resolution  

E-Print Network [OSTI]

We experimentally demonstrate nanoscopic transmission microscopy relying on a deterministic single particle source. This increases the signal-to-noise ratio with respect to conventional microscopy methods, which employ Poissonian particle sources. We use laser-cooled ions extracted from a Paul trap, and demonstrate remote imaging of transmissive objects with a resolution of 8.6 $\\pm$ 2.0nm and a minimum two-sample deviation of the beam position of 1.5nm. Detector dark counts can be suppressed by 6 orders of magnitudes through gating by the extraction event. The deterministic nature of our source enables an information-gain driven approach to imaging. We demonstrate this by performing efficient beam characterization based on a Bayes experiment design method.

Georg Jacob; Karin Groot-Berning; Sebastian Wolf; Stefan Ulm; Luc Couturier; Ulrich G. Poschinger; Ferdinand Schmidt-Kaler; Kilian Singer

2014-05-26T23:59:59.000Z

222

Time-resolved x-ray imaging of high-power laser-irradiated under-dense silica aerogels and agar foams  

SciTech Connect (OSTI)

This paper presents the results of experiments in which a high-power laser was used to irradiate low density (4 - 9 mg/cm{sup 3}) silica aerogel and agar foam targets. The laser-solid interaction and energy transport through the material were monitored with time-resolved imaging diagnostics, and the data show the production and propagation of an x-ray emission front in the plasma. The emission-front trajectory data are found to be in significant disagreement with detailed simulations, which predict a much more rapid heating of the cold material, and the data suggest that this discrepancy is not explainable by target inhomogeneities. Evidence suggests that energy transport into the cold material may be dominated by thermal conduction; however, no completely satisfactory explanation for the discrepancies is identified, and further experimental and theoretical research is necessary in order to resolve this important problem in laser-plasma interaction physics.

Koch, J.A.; Estabrook, K.G.; Bauer, J.D. [and others

1995-08-01T23:59:59.000Z

223

Tracking of the advance of the coagulation front in a laser irradiated tissue using ultrasound imaging  

E-Print Network [OSTI]

, perpendicular to the axis of rotation. T;"re signal bounced off jrcficcted from) the object, a piece of beef. This rcfiection ivas received by the transducer. The trarrsducer rvas operated on a B-Scan mode. Using this scanner the images v crc. obtained...?b('ca(is&. of he in!i&i'i'eiii, iioisc that ii as f)resent, iii th('. u!1 rasoiuid 'iiiage du(' to sl)(ck!e. Various cuive fitting pr&)(cdures like iaol&nomial curve. Gaiissian ciirve, e!liptical curve fitting etc. were examined. The data ivas analyzed hy thi...

Jagathesan, Shoban Srikrishna

1993-01-01T23:59:59.000Z

224

Femtosecond diffractive imaging with a soft-X-ray free-electron laser  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation ProposedUsing ZirconiaPolicyFeasibility of SF(STEO) ï‚·diffractive imaging with a soft-X-ray

225

Upgrades of imaging x-ray crystal spectrometers for high-resolution and high-temperature plasma diagnostics on EAST  

SciTech Connect (OSTI)

Upgrade of the imaging X-ray crystal spectrometers continues in order to fulfill the high-performance diagnostics requirements on EAST. For the tangential spectrometer, a new large pixelated two-dimensional detector was deployed on tokamaks for time-resolved X-ray imaging. This vacuum-compatible detector has an area of 83.8 × 325.3 mm{sup 2}, a framing rate over 150 Hz, and water-cooling capability for long-pulse discharges. To effectively extend the temperature limit, a double-crystal assembly was designed to replace the previous single crystals for He-like argon line measurement. The tangential spectrometer employed two crystal slices attached to a common substrate and part of He- and H-like Ar spectra could be recorded on the same detector when crystals were chosen to have similar Bragg angles. This setup cannot only extend the measurable Te up to 10 keV in the core region, but also extend the spatial coverage since He-like argon ions will be present in the outer plasma region. Similarly, crystal slices for He-like iron and argon spectra were adopted on the poloidal spectrometer. Wavelength calibration for absolute rotation velocity measurement will be studied using cadmium characteristic L-shell X-ray lines excited by plasma radiation. A Cd foil is placed before the crystal and can be inserted and retracted for in situ wavelength calibration. The Geant4 code was used to estimate X-ray fluorescence yield and optimize the thickness of the foil.

Lyu, B., E-mail: blu@ipp.ac.cn; Wang, F. D.; Fu, J.; Li, Y. Y. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Pan, X. Y.; Chen, J.; Wan, B. N. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui 230026 (China); Bitter, M.; Hill, K. W.; Delgado-Aparicio, L. F.; Pablant, N. [Princeton Plasma Physics Laboratory, P.O. Box 451, Princeton, New Jersey 08543-0451 (United States); Lee, S. G. [National Fusion Research Institute, 52 Eoeun-Dong, Yusung-Gu, Daejeon 305-333 (Korea, Republic of); Shi, Y. J. [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui 230026 (China); WCI for Fusion Theory, National Fusion Research Institute, 52 Eoeun-Dong, Yusung-Gu, Daejeon 305-333 (Korea, Republic of); Ye, M. Y. [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui 230026 (China)

2014-11-15T23:59:59.000Z

226

Characterization of spatially resolved high resolution x-ray spectrometers for high energy density physics and light source experiments  

SciTech Connect (OSTI)

A high resolution 1D imaging x-ray spectrometer concept comprising a spherically bent crystal and a 2D pixelated detector is being optimized for diagnostics of small sources such as high energy density physics (HEDP) and synchrotron radiation or x-ray free electron laser experiments. This instrument is used on tokamak experiments for Doppler measurements of ion temperature and plasma flow velocity profiles. Laboratory measurements demonstrate a resolving power, E/?E of order 10?000 and spatial resolution better than 10 ?m. Initial tests of the high resolution instrument on HEDP plasmas are being performed.

Hill, K. W., E-mail: khill@pppl.gov; Bitter, M.; Delgado-Aparacio, L.; Efthimion, P.; Pablant, N. A. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Lu, J. [Key Laboratory of Optoelectronic Technology and System of Ministry of Education, Chongqing University, Chongqing 400030 (China); Beiersdorfer, P.; Chen, H.; Magee, E. [Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

2014-11-15T23:59:59.000Z

227

Perfusion-based High-Resolution Functional Imaging in the Human Brain at 7 Tesla J. Pfeuffer, G. Adriany, A. Shmuel, E. Yacoub, P.-F. van de Moortele, X. Hu, K. Ugurbil  

E-Print Network [OSTI]

Perfusion-based High-Resolution Functional Imaging in the Human Brain at 7 Tesla J. Pfeuffer, G was made possible by signal-to-noise gains at the high magnetic field of 7 Tesla and by using a novel RF

228

On the possibility of designing a high-resolution heterodyne spectrometer for near-IR range on the basis of a tunable diode laser  

SciTech Connect (OSTI)

The results of heterodyning of broadband radiation in the near-IR range are presented. A stabilised DFB laser was used as a local oscillator, while the role of a broadband radiation source was played by another DFB laser, excited by the pump current below its threshold value. A fibre-optical Y-coupler based on the single-mode silica fibre served as a diplexer. The radiation mixed in the singlemode fibre was incident on the photodetector, the role of which was played by a p - i - n photodiode. The signal from the photodiode was amplified by the preamplifier with the feedback resistance 240 k{Omega} and the bandwidth {approx}1 MHz and then digitised using a 16-digit ADC. The frequency scanning was implemented via the variation of the local oscillator frequency. The developed registration system provides the sensitivity {approx}1.4 % of the shot noise value at the acquisition time {approx}40 min.

Klimchuk, A Yu; Nadezhdinskii, Aleksandr I; Ponurovskii, Ya Ya; Shapovalov, Yu P; Rodin, A V

2012-03-31T23:59:59.000Z

229

X-ray phase contrast imaging of biological specimens with femtosecond pulses of betatron radiation from a compact laser plasma wakefield accelerator  

SciTech Connect (OSTI)

We show that x-rays from a recently demonstrated table top source of bright, ultrafast, coherent synchrotron radiation [Kneip et al., Nat. Phys. 6, 980 (2010)] can be applied to phase contrast imaging of biological specimens. Our scheme is based on focusing a high power short pulse laser in a tenuous gas jet, setting up a plasma wakefield accelerator that accelerates and wiggles electrons analogously to a conventional synchrotron, but on the centimeter rather than tens of meter scale. We use the scheme to record absorption and phase contrast images of a tetra fish, damselfly and yellow jacket, in particular highlighting the contrast enhancement achievable with the simple propagation technique of phase contrast imaging. Coherence and ultrafast pulse duration will allow for the study of various aspects of biomechanics.

Kneip, S. [Blackett Laboratory, Imperial College London, London SW7 2AZ (United Kingdom); Center for Ultrafast Optical Science, University of Michigan, Ann Arbor 48109 (United States); McGuffey, C.; Dollar, F.; Chvykov, V.; Kalintchenko, G.; Krushelnick, K.; Maksimchuk, A.; Mangles, S. P. D.; Matsuoka, T.; Schumaker, W.; Thomas, A. G. R.; Yanovsky, V. [Center for Ultrafast Optical Science, University of Michigan, Ann Arbor 48109 (United States); Bloom, M. S.; Najmudin, Z.; Palmer, C. A. J.; Schreiber, J. [Blackett Laboratory, Imperial College London, London SW7 2AZ (United Kingdom)

2011-08-29T23:59:59.000Z

230

Laser Guide Star Adaptive Optics without Tip-tilt  

E-Print Network [OSTI]

Adaptive optics (AO) systems allow a telescope to reach its diffraction limit at near infrared wavelengths. But to achieve this, a bright natural guide star (NGS) is needed for the wavefront sensing, severely limiting the fraction of the sky over which AO can be used. To some extent this can be overcome with a laser guide star (LGS). While the laser can be pointed anywhere in the sky, one still needs to have a natural star, albeit fainter, reasonably close to correct the image motion (tip-tilt) to which laser guide stars are insensitive. There are in fact many astronomical targets without suitable tip-tilt stars, but for which the enhanced resolution obtained with the Laser Guide Star Facility (LGSF) would still be very beneficial. This article explores what adaptive optics performance one might expect if one dispenses with the tip-tilt star, and in what situations this mode of observing might be needed.

R. Davies; S. Rabien; C. Lidman; M. Le Louarn; M. Kasper; N. M. Forster Schreiber; V. Roccatagliata; N. Ageorges; P. Amico; C. Dumas; F. Mannucci

2008-01-24T23:59:59.000Z

231

Characterisation of deuterium spectra from laser driven multi-species sources by employing differentially filtered image plate detectors in Thomson spectrometers  

SciTech Connect (OSTI)

A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C{sup 6+}, O{sup 8+}, etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented, which was produced from a thin deuterated plastic foil target irradiated by a high power laser.

Alejo, A.; Kar, S., E-mail: s.kar@qub.ac.uk; Ahmed, H.; Doria, D.; Green, A.; Jung, D.; Lewis, C. L. S.; Nersisyan, G. [Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast BT7 1NN (United Kingdom); Krygier, A. G.; Freeman, R. R. [Department of Physics, The Ohio State University, Columbus, Ohio 43210 (United States); Clarke, R.; Green, J. S.; Notley, M. [Central Laser Facility, Rutherford Appleton Laboratory, Didcot, Oxfordshire OX11 0QX (United Kingdom); Fernandez, J. [Central Laser Facility, Rutherford Appleton Laboratory, Didcot, Oxfordshire OX11 0QX (United Kingdom); Instituto de Fusión Nuclear, Universidad Politécnica de Madrid, 28006 Madrid (Spain); Fuchs, J. [LULI, École Polytechnique, CNRS, CEA, UPMC, 91128 Palaiseau (France); Kleinschmidt, A.; Roth, M. [Institut für Kernphysik, Technische Universität Darmstadt, Schloßgartenstrasse 9, D-64289 Darmstadt (Germany); Morrison, J. T. [Propulsion Systems Directorate, Air Force Research Lab, Wright Patterson Air Force Base, Ohio 45433 (United States); Najmudin, Z.; Nakamura, H. [Blackett Laboratory, Department of Physics, Imperial College, London SW7 2AZ (United Kingdom); and others

2014-09-15T23:59:59.000Z

232

Note: Design and construction of a multi-scale, high-resolution, tube-generated X-Ray computed-tomography system for three-dimensional (3D) imaging  

SciTech Connect (OSTI)

The design and construction of a high resolution modular x-ray computed tomography (XCT) system is described. The approach for meeting a specified set of performance goals tailored toward experimental versatility is highlighted. The instrument is unique in its detector and x-ray source configuration, both of which enable elevated optimization of spatial and temporal resolution. The process for component selection is provided. The selected components are specified, the custom component design discussed, and the integration of both into a fully functional XCT instrument is outlined. The novelty of this design is a new lab-scale detector and imaging optimization through x-ray source and detector modularity.

Mertens, J. C. E.; Williams, J. J.; Chawla, Nikhilesh [Materials Science and Engineering, Security and Defense Systems Initiative, Arizona State University, 781 E. Terrace Road, ISTB4, Tempe, Arizona 85287-5604 (United States)] [Materials Science and Engineering, Security and Defense Systems Initiative, Arizona State University, 781 E. Terrace Road, ISTB4, Tempe, Arizona 85287-5604 (United States)

2014-01-15T23:59:59.000Z

233

atomic-resolution imaging | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

at this time. Molecular Hydrogen Formation from Proximal Glycol Pairs on TiO2(110). Abstract: Understanding hydrogen formation on TiO2 surfaces is of great importance as it...

234

Dilation x-ray imager a new/faster gated x-ray imager for the NIF  

SciTech Connect (OSTI)

As the yield on implosion shots increases it is expected that the peak x-ray emission reduces to a duration with a FWHM as short as 20 ps for {approx}7 Multiplication-Sign 10{sup 18} neutron yield. However, the temporal resolution of currently used gated x-ray imagers on the NIF is 40-100 ps. We discuss the benefits of the higher temporal resolution for the NIF and present performance measurements for dilation x-ray imager, which utilizes pulse-dilation technology [T. J. Hilsabeck et al., Rev. Sci. Instrum. 81, 10E317 (2010)] to achieve x-ray imaging with temporal gate times below 10 ps. The measurements were conducted using the COMET laser, which is part of the Jupiter Laser Facility at the Lawrence Livermore National Laboratory.

Nagel, S. R.; Bell, P. M.; Bradley, D. K.; Ayers, M. J.; Barrios, M. A.; Felker, B.; Smith, R. F.; Collins, G. W.; Jones, O. S.; Piston, K.; Raman, K. S. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States); Hilsabeck, T. J.; Kilkenny, J. D.; Chung, T.; Sammuli, B. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Hares, J. D.; Dymoke-Bradshaw, A. K. L. [Kentech Instruments Ltd., Wallingford, Oxfordshire OX10 (United Kingdom)

2012-10-15T23:59:59.000Z

235

Injection-controlled laser resonator  

DOE Patents [OSTI]

A new injection-controlled laser resonator incorporates self-filtering and self-imaging characteristics with an efficient injection scheme. A low-divergence laser signal is injected into the resonator, which enables the injection signal to be converted to the desired resonator modes before the main laser pulse starts. This injection technique and resonator design enable the laser cavity to improve the quality of the injection signal through self-filtering before the main laser pulse starts. The self-imaging property of the present resonator reduces the cavity induced diffraction effects and, in turn, improves the laser beam quality. 5 figs.

Chang, J.J.

1995-07-18T23:59:59.000Z

236

Final Technical Report for DE-FG02-06ER15835: Chemical Imaging with 100nm Spatial Resolution: Combining High Resolution Flurosecence Microscopy and Ion Mobility Mass Spectrometry  

SciTech Connect (OSTI)

We have combined, in a single instrument, high spatial resolution optical microscopy with the chemical specificity and conformational selectivity of ion mobility mass spectrometry. We discuss the design and construction of this apparatus as well as our efforts in applying this technique to thin films of molecular semiconductor materials.

Buratto, Steven K. [UC Santa Barbara

2013-09-03T23:59:59.000Z

237

High resolution data acquisition  

DOE Patents [OSTI]

A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

Thornton, Glenn W. (Los Alamos, NM); Fuller, Kenneth R. (Los Alamos, NM)

1993-01-01T23:59:59.000Z

238

High resolution data acquisition  

DOE Patents [OSTI]

A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock, pulse train, and analog circuitry for generating a triangular wave synchronously with the pulse train (as seen in diagram on patent). The triangular wave has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter counts the clock pulse train during the interval to form a gross event interval time. A computer then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

Thornton, G.W.; Fuller, K.R.

1993-04-06T23:59:59.000Z

239

Laser Scanning Confocal Microscopy Study of Dye Diffusion in Fibers Ye Song, Mohan Srinivasarao,*, Alan Tonelli, C. M. Balik, and Ralph McGregor  

E-Print Network [OSTI]

Laser Scanning Confocal Microscopy Study of Dye Diffusion in Fibers Ye Song, Mohan Srinivasarao to noninvasively obtain high-resolution three-dimensional images of the spatial distribution of dyes (fluorescein) in fibers dyed for various length of times. Integration over the dye distribution yields the total amount

Srinivasarao, Mohan

240

Imaging  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert Southwest Region service area.Portaldefault Sign In About |Imaging Imaging Print

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

ORION laser target diagnostics  

SciTech Connect (OSTI)

The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

Bentley, C. D.; Edwards, R. D.; Andrew, J. E.; James, S. F.; Gardner, M. D.; Comley, A. J.; Vaughan, K.; Horsfield, C. J.; Rubery, M. S.; Rothman, S. D.; Daykin, S.; Masoero, S. J.; Palmer, J. B.; Meadowcroft, A. L.; Williams, B. M.; Gumbrell, E. T.; Fyrth, J. D.; Brown, C. R. D.; Hill, M. P.; Oades, K. [Plasma Physics Department, Atomic Weapons Establishment, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom); and others

2012-10-15T23:59:59.000Z

242

Imaging X-ray Thomson Scattering Spectrometer Design and Demonstration  

SciTech Connect (OSTI)

In many laboratory astrophysics experiments, intense laser irradiation creates novel material conditions with large, one-dimensional gradients in the temperature, density, and ionization state. X-ray Thomson scattering is a powerful technique for measuring these plasma parameters. However, the scattered signal has previously been measured with little or no spatial resolution, which limits the ability to diagnose inhomogeneous plasmas. We report on the development of a new imaging x-ray Thomson spectrometer (IXTS) for the Omega laser facility. The diffraction of x-rays from a toroidally-curved crystal creates high-resolution images that are spatially resolved along a one-dimensional profile while spectrally dispersing the radiation. This focusing geometry allows for high brightness while localizing noise sources and improving the linearity of the dispersion. Preliminary results are presented from a scattering experiment that used the IXTS to measure the temperature profile of a shocked carbon foam.

Gamboa, E.J. [University of Michigan; Huntington, C.M. [University of Michigan; Trantham, M.R. [University of Michigan; Keiter, P.A [University of Michigan; Drake, R.P. [University of Michigan; Montgomery, David [Los Alamos National Laboratory; Benage, John F. [Los Alamos National Laboratory; Letzring, Samuel A. [Los Alamos National Laboratory

2012-05-04T23:59:59.000Z

243

Quantitative imaging of turbulent and reacting flows  

SciTech Connect (OSTI)

Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and spatial resolution in the imaging system as well as developing excitation/detection strategies which provide for a quantitative measure of particular flowfield scalars. The standard camera used for the study is an intensified CCD array operated in a conventional video format. The design of the system was based on detailed modeling of signal and image transfer properties of fast UV imaging lenses, image intensifiers and CCD detector arrays. While this system is suitable for direct scalar imaging, derived quantities (e.g. temperature or velocity images) require an exceptionally wide dynamic range imaging detector. To apply these diagnostics to reacting flows also requires a very fast shuttered camera. The authors have developed and successfully tested a new type of gated low-light level detector. This system relies on fast switching of proximity focused image-diode which is direct fiber-optic coupled to a cooled CCD array. Tests on this new detector show significant improvements in detection limit, dynamic range and spatial resolution as compared to microchannel plate intensified arrays.

Paul, P.H. [Sandia National Laboratories, Livermore, CA (United States)

1993-12-01T23:59:59.000Z

244

Imaging  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-SeriesFlickr FlickrGuidedCH2MLLCBasicsScience atIanIgorIlyaBuildingImaging Print

245

Imaging  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-SeriesFlickr FlickrGuidedCH2MLLCBasicsScience atIanIgorIlyaBuildingImaging

246

Multichannel, time-resolved picosecond laser ultrasound imaging and spectroscopy with custom complementary metal-oxide-semiconductor detector  

SciTech Connect (OSTI)

This paper presents a multichannel, time-resolved picosecond laser ultrasound system that uses a custom complementary metal-oxide-semiconductor linear array detector. This novel sensor allows parallel phase-sensitive detection of very low contrast modulated signals with performance in each channel comparable to that of a discrete photodiode and a lock-in amplifier. Application of the instrument is demonstrated by parallelizing spatial measurements to produce two-dimensional thickness maps on a layered sample, and spectroscopic parallelization is demonstrated by presenting the measured Brillouin oscillations from a gallium arsenide wafer. This paper demonstrates the significant advantages of our approach to pump probe systems, especially picosecond ultrasonics.

Smith, Richard J.; Light, Roger A.; Johnston, Nicholas S.; Pitter, Mark C.; Somekh, Mike G. [Institute of Biophysics, Imaging and Optical Science, University of Nottingham, Nottinghamshire NG7 2RD (United Kingdom); Sharples, Steve D. [Applied Optics Group, Electrical Systems and Optics Research Division, University of Nottingham, Nottinghamshire NG7 2RD (United Kingdom)

2010-02-15T23:59:59.000Z

247

Development of a frequency doubled high powered laser diode end-pumped Nd:YVO?/LBO laser  

E-Print Network [OSTI]

to determine the temperature distribution within the laser media. Experiments are performed to characterize the laser diode spectral output and laser crystal response to the pump radiation. Finally, the thesis presents a simple technique to image infrared...

Barr, Aaron Maxwell

2012-06-07T23:59:59.000Z

248

Detailed modeling and laser-induced fluorescence imaging of nitric oxide in a NH(i)-seeded non-premixed methane/air flame  

SciTech Connect (OSTI)

In this paper we study the formation of NO in laminar, nitrogen diluted methane diffusion flames that are seeded with ammonia in the fuel stream. We have performed numerical simulations with detailed chemistry as well as laser-induced fluorescence imaging measurements for a range of ammonia injection rates. For comparison with the experimental data, synthetic LIF images are calculated based on the numerical data accounting for temperature and fluorescence quenching effects. We demonstrate good agreement between measurements and computations. The LIF corrections inferred from the simulation are then used to calculate absolute NO mole fractions from the measured signal.The NO formation in both doped and undoped flames occurs in the flame sheet. In the undoped flame, four different mechanisms including thermal and prompt NO appear to contribute to NO formation. As the NH3 seeding level increases, fuel-NO becomes the dominant mechanism and N2 shifts from being a net reactant to being a net product. Nitric oxide in the undoped flame as well as in the core region of the doped flames are underpredicted by the model; we attribute this mainly to inaccuracies in the NO recycling chemistry on the fuel-rich side of the flame sheet.

Bell, John B.; Day, Marcus S.; Grcar, Joseph F.; Bessler, Wolfgang G.; Schulz, Christof; Glarborg, Peter; Jensen, Anker D.

2001-12-14T23:59:59.000Z

249

Low-Altitude Laser Altimeter to Assist UAV Autolanding  

E-Print Network [OSTI]

This project presents a low-altitude laser altimeter system to assist UAV autolanding. This system generates aircraft altitude and attitude estimates; it consists of laser illuminators, a digital imaging unit (image sensor, lens, and optical filter...

Bergmann, Nicholas M

2012-08-31T23:59:59.000Z

250

A laser speckle based position sensing technique  

E-Print Network [OSTI]

This thesis presents the design and development of a novel laser-speckle-based position sensing technique. In our prototype implementation, a He-Ne laser beam is directed at the surface of an air-bearing spindle. An imaging ...

Shilpiekandula, Vijay, 1979-

2004-01-01T23:59:59.000Z

251

Monte Carlo study for optimal conditions in single-shot imaging with femtosecond x-ray laser pulses  

SciTech Connect (OSTI)

Intense x-ray pulses from x-ray free electron lasers (XFELs) enable the unveiling of atomic structure in material and biological specimens via ultrafast single-shot exposures. As the radiation is intense enough to destroy the sample, a new sample must be provided for each x-ray pulse. These single-particle delivery schemes require careful optimization, though systematic study to find such optimal conditions is still lacking. We have investigated two major single-particle delivery methods: particle injection as flying objects and membrane-mount as fixed targets. The optimal experimental parameters were searched for via Monte Carlo simulations to discover that the maximum single-particle hit rate achievable is close to 40%.

Park, Jaehyun; Ishikawa, Tetsuya; Song, Changyong [RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo, Hyogo 679-5148 (Japan)] [RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo, Hyogo 679-5148 (Japan); Joti, Yasumasa [Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)] [Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

2013-12-23T23:59:59.000Z

252

Image processing applications in NDE  

SciTech Connect (OSTI)

Nondestructive examination (NDE) can be defined as a technique or collection of techniques that permits one to determine some property of a material or object without damaging the object. There are a large number of such techniques and most of them use visual imaging in one form or another. They vary from holographic interferometry where displacements under stress are measured to the visual inspection of an objects surface to detect cracks after penetrant has been applied. The use of image processing techniques on the images produced by NDE is relatively new and can be divided into three general categories: classical image enhancement; mensuration techniques; and quantitative sensitometry. An example is discussed of how image processing techniques are used to nondestructively and destructively test the product throughout its life cycle. The product that will be followed is the microballoon target used in the laser fusion program. The laser target is a small (50 to 100 ..mu..m - dia) glass sphere with typical wall thickness of 0.5 to 6 ..mu..m. The sphere may be used as is or may be given a number of coatings of any number of materials. The beads are mass produced by the millions and the first nondestructive test is to separate the obviously bad beads (broken or incomplete) from the good ones. After this has been done, the good beads must be inspected for spherocity and wall thickness uniformity. The microradiography of the glass, uncoated bead is performed on a specially designed low-energy x-ray machine. The beads are mounted in a special jig and placed on a Kodak high resolution plate in a vacuum chamber that contains the x-ray source. The x-ray image is made with an energy less that 2 keV and the resulting images are then inspected at a magnification of 500 to 1000X. Some typical results are presented.

Morris, R.A.

1980-01-01T23:59:59.000Z

253

Large Area and High Efficiency Photon Counting Imaging Detectors with High Time and Spatial Resolution for Night Time Sensing and Astronomy  

E-Print Network [OSTI]

and background rates of ~50 kHz at 8° C. The sensor system including our processing electronics achieves spatial National Laboratory, Chicago Il Gary Varner University of Hawaii ABSTRACT Imaging sensors using Ga, low background rates (0.1 events cm-2 sec-1 ), and very good lifetime stability to 7 C cm-2 of charge

Michalet, Xavier

254

Device for translating negative film image to a line scan  

DOE Patents [OSTI]

A negative film reader records high-resolution optical density changes across negative film radiographic images to allow precise image dimensions to be determined. A laser light source capable of high-resolution focusing is passed through an intensity control filter, focused by a lens, and reflected off a mirror to focus in the plane of the negative film. The light transmitted through the film is collected by a second lens and directed to a photo diode detector which senses the transmitted intensity. The output of the photo diode signal amplifier is sent to the Y-axis input of an X-Y recorder. The film sample is transported in a plane perpendicular to the beam axis by means of a slide. The film position is monitored, with the signal amplified and recorded as the X-axis on the X-Y recorder. The linear dimensions and positions of image components can be determined by direct measurement of the amplified recording.

Dutton, G.W.

1998-05-19T23:59:59.000Z

255

Laser-induced metallic nanograined thin films processing  

SciTech Connect (OSTI)

A direct laser writing method for designing metallic nanograined thin films is presented. This method takes advantage of photon conversion within a chemical process localized at the focal point. A computer controlled positioning system allows the control of experimental parameters and spatial resolution of the pattern. Spectroscopic investigations reveal variable attenuation of the optical properties in UV-visible range and a spectral imaging processing algorithm simulated the functionality of these films in visible light. This could be an important step for obtaining neutral density attenuators.

Tosa, Nicoleta, E-mail: nicoleta.tosa@itim-cj.ro, E-mail: florin.toadere@itim-cj.ro; Toadere, Florin, E-mail: nicoleta.tosa@itim-cj.ro, E-mail: florin.toadere@itim-cj.ro; Hojbota, Calin, E-mail: nicoleta.tosa@itim-cj.ro, E-mail: florin.toadere@itim-cj.ro; Tosa, Valer, E-mail: nicoleta.tosa@itim-cj.ro, E-mail: florin.toadere@itim-cj.ro [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath., 400293 Cluj-Napoca (Romania)] [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath., 400293 Cluj-Napoca (Romania)

2013-11-13T23:59:59.000Z

256

PRECISE THROUGHPUT DETERMINATION OF THE PanSTARRS TELESCOPE AND THE GIGAPIXEL IMAGER USING A CALIBRATED SILICON PHOTODIODE AND A TUNABLE LASER: INITIAL RESULTS  

SciTech Connect (OSTI)

We have used a precision-calibrated photodiode as the fundamental metrology reference in order to determine the relative throughput of the PanSTARRS telescope and the Gigapixel imager, from 400 nm to 1050 nm. Our technique uses a tunable laser as a source of illumination on a transmissive flat-field screen. We determine the full-aperture system throughput as a function of wavelength, including (in a single integral measurement) the mirror reflectivity, the transmission functions of the filters and the corrector optics, and the detector quantum efficiency, by comparing the light seen by each pixel in the CCD array to that measured by a precision-calibrated silicon photodiode. This method allows us to determine the relative throughput of the entire system as a function of wavelength, for each pixel in the instrument, without observations of celestial standards. We present promising initial results from this characterization of the PanSTARRS system, and we use synthetic photometry to assess the photometric perturbations due to throughput variation across the field of view.

Stubbs, Christopher W.; Doherty, Peter; Cramer, Claire; Narayan, Gautham; Brown, Yorke J. [Department of Physics, 17 Oxford Street Harvard University, Cambridge MA 02138 (United States); Lykke, Keith R.; Woodward, John T. [National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg MD 20899 (United States); Tonry, John L., E-mail: stubbs@physics.harvard.ed [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu HI 96822 (United States)

2010-12-15T23:59:59.000Z

257

Diagnostic probes for particle and molecule distributions in laser-generated plumes  

SciTech Connect (OSTI)

Laser microprobe analysis (LMA) offers good spatial and depth resolution for solid sampling of virtually any material. Coupled with numerous optical spectroscopic and mass spectrometric detection methods, LMA is a powerful analytical tool. Yet, fundamental understanding of the interaction between the laser and the sample surface leading to the formation of the high temperature plasma (plume) is far from complete. To better understand the process of plume formation, an imaging method based on acousto-optic laser beam deflection has been coupled with light scattering methods and absorption methods to record temporal and spatial maps of the particle and molecule distributions in the plume with good resolution. Because particles can make up a major fraction of the vaporized material under certain operating conditions, they can reflect a large loss of atomic signal for elemental analysis, even when using auxiliary excitation to further vaporized the particles. Characterization of the particle size distributions in plumes should provide insight into the vaporization process and information necessary for studies of efficient particle transfer. Light scattering methods for particle size analysis based on the Mie Theory are used to determine the size of particles in single laser-generated plumes. The methods used, polarization ratio method and dissymmetry ratio method, provide good estimates of particle size with good spatial and temporal resolution for this highly transient system. Large particles, on the order of 0.02-0.2{mu}m in radius, were observed arising directly from the sample surface and from condensation.

Kimbrell, S.M.

1990-10-17T23:59:59.000Z

258

High resolution scintillation detector with semiconductor readout  

DOE Patents [OSTI]

A novel high resolution scintillation detector array for use in radiation imaging such as high resolution Positron Emission Tomography (PET) which comprises one or more parallelepiped crystals with at least one long surface of each crystal being in intimate contact with a semiconductor photodetector such that photons generated within each crystal by gamma radiation passing therethrough is detected by the photodetector paired therewith.

Levin, Craig S. (Santa Monica, CA); Hoffman, Edward J. (Los Angeles, CA)

2000-01-01T23:59:59.000Z

259

atomic resolution structure: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

An axis of 3-fold symmetry runs through Blaber, Michael 8 Crystal structure retrieval by maximum entropy analysis of atomic resolution incoherent images Materials Science Websites...

260

atomic resolution structural: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

An axis of 3-fold symmetry runs through Blaber, Michael 8 Crystal structure retrieval by maximum entropy analysis of atomic resolution incoherent images Materials Science Websites...

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

atomic resolution structures: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

An axis of 3-fold symmetry runs through Blaber, Michael 8 Crystal structure retrieval by maximum entropy analysis of atomic resolution incoherent images Materials Science Websites...

262

Laser Atmospheric Studies with VERITAS  

E-Print Network [OSTI]

As a calibrated laser pulse propagates through the atmosphere, the amount of Rayleigh-scattered light arriving at the VERITAS telescopes can be calculated precisely. This technique was originally developed for the absolute calibration of ultra-high-energy cosmic-ray fluorescence telescopes but is also applicable to imaging atmospheric Cherenkov telescopes (IACTs). In this paper, we present two nights of laser data taken with the laser at various distances away from the VERITAS telescopes and compare it to Rayleigh scattering simulations.

C. M. Hui; for the VERITAS collaboration

2007-09-25T23:59:59.000Z

263

NMR imaging of materials  

SciTech Connect (OSTI)

Interest in the area of NMR imaging has been driven by the widespread success of medical imaging. John M. Listerud of the Pendergrass Diagnostic Research Laboratories, Steven W. Sinton of Lockheed, and Gary P. Drobny of the University of Washington describe the principal image reconstruction methods, factors limiting spatial resolution, and applications of imaging to the study of materials.

Listerud, J.M.; Sinton, S.W.; Drobny, G.P.

1989-01-01T23:59:59.000Z

264

Subdiffraction, Luminescence-Depletion Imaging of Isolated, Giant, CdSe/CdS Nanocrystal Quantum Dots  

SciTech Connect (OSTI)

Subdiffraction spatial resolution luminescence depletion imaging was performed with giant CdSe/14CdS nanocrystal quantum dots (g-NQDs) dispersed on a glass slide. Luminescence depletion imaging used a Gaussian shaped excitation laser pulse overlapped with a depletion pulse, shaped into a doughnut profile, with zero intensity in the center. Luminescence from a subdiffraction volume is collected from the central portion of the excitation spot, where no depletion takes place. Up to 92% depletion of the luminescence signal was achieved. An average full width at half-maximum of 40 ± 10 nm was measured in the lateral direction for isolated g-NQDs at an air interface using luminescence depletion imaging, whereas the average full width at half-maximum was 450 ± 90 nm using diffraction-limited, confocal luminescence imaging. Time-gating of the luminescence depletion data was required to achieve the stated spatial resolution. No observable photobleaching of the g-NQDs was present in the measurements, which allowed imaging with a dwell time of 250 ms per pixel to obtain images with a high signal-to-noise ratio. The mechanism for luminescence depletion is likely stimulated emission, stimulated absorption, or a combination of the two. The g-NQDs fulfill a need for versatile, photostable tags for subdiffraction imaging schemes where high laser powers or long exposure times are used.

Lesoine, Michael D. [Ames Laboratory; Bhattacharjee, Ujjal [Ames Laboratory; Guo, Yijun [Ames Laboratory; Vela, Javier [Ames Laboratory; Petrich, Jacob W. [Ames Laboratory; Smith, Emily A. [Ames Laboratory

2013-01-18T23:59:59.000Z

265

Mapping DNAPL transport contamination in sedimentary and fractured rock aquifers with high resolution borehole seismic imaging Project No. SF11SS13 FY01 Annual Report  

SciTech Connect (OSTI)

This report covers the work performed in the first year of a three-year project funded by the USDOE's Subsurface Contaminant Focus Area (SCFA). The objectives of this project are to develop, demonstrate and evaluate, at appropriate field sites, the utility of high frequency seismic imaging methods to detect and characterize non-aqueous phase liquid (NAPL) contamination in sedimentary and fractured rock aquifers. Field tests consist of crosswell seismic tomography acquired before, during and after any remediation action that would potentially affect fluid distributions. Where feasible, other characterization data is obtained, such as crosswell radar, borehole conductivity and cone penetration testing (CPT). Crosswell data are processed to obtain tomographic images, or two-dimensional distributions, of velocity and attenuation. The interpretation of the tomograms utilizes all available site characterization data to relate the geophysical attributes to lithology and fluid phase heterogeneities. Interpretations are validated by evaluation and testing of field cores. Laboratory tests on core retrieved from surveyed locations are performed to determine the relationships between geophysical parameters and solid and fluid phase composition. In the case of sedimentary aquifers, proof of principle has been demonstrated previously in homogeneous sand-packs at the centimeter and half-meter scale (Geller and Myer, 1995; Geller et al., 2000). The field tests will provide proof-of-principle at the field-scale, by working in an unconsolidated sand aquifer with known presence of NAPL. The ability to upscale from the laboratory to the field is evaluated by conducting field measurements over a range of frequencies that overlap the lowest frequencies used in the laboratory tests. In the fractured rock case, previous field work has shown that fracture zones can be detected by crosswell seismic tomography (Daley et al., 2001; Daley et al., 2000). Laboratory studies have demonstrated that the seismic wave signature is sensitive to the fracture stiffness, and that stiffness is affected by fracture-filling fluids (Pyrak-Nolte and Morris, 2000; Pyrak-Nolte, 1996). The field and laboratory experience provide a physical basis for the potential detection of fractures that would be the important flow paths for NAPL contaminants.

Geller, J.T.; Majer, E.L.; Peterson, J.E.; Williams, K.H.; Flexser, S.

2001-12-01T23:59:59.000Z

266

Method and apparatus for coherent imaging of infrared energy  

DOE Patents [OSTI]

A coherent camera system performs ranging, spectroscopy, and thermal imaging. Local oscillator radiation is combined with target scene radiation to enable heterodyne detection by the coherent camera`s two-dimensional photodetector array. Versatility enables deployment of the system in either a passive mode (where no laser energy is actively transmitted toward the target scene) or an active mode (where a transmitting laser is used to actively illuminate the target scene). The two-dimensional photodetector array eliminates the need to mechanically scan the detector. Each element of the photodetector array produces an intermediate frequency signal that is amplified, filtered, and rectified by the coherent camera`s integrated circuitry. By spectroscopic examination of the frequency components of each pixel of the detector array, a high-resolution, three-dimensional or holographic image of the target scene is produced for applications such as air pollution studies, atmospheric disturbance monitoring, and military weapons targeting. 8 figs.

Hutchinson, D.P.

1998-05-12T23:59:59.000Z

267

Method and apparatus for coherent imaging of infrared energy  

DOE Patents [OSTI]

A coherent camera system performs ranging, spectroscopy, and thermal imaging. Local oscillator radiation is combined with target scene radiation to enable heterodyne detection by the coherent camera's two-dimensional photodetector array. Versatility enables deployment of the system in either a passive mode (where no laser energy is actively transmitted toward the target scene) or an active mode (where a transmitting laser is used to actively illuminate the target scene). The two-dimensional photodetector array eliminates the need to mechanically scan the detector. Each element of the photodetector array produces an intermediate frequency signal that is amplified, filtered, and rectified by the coherent camera's integrated circuitry. By spectroscopic examination of the frequency components of each pixel of the detector array, a high-resolution, three-dimensional or holographic image of the target scene is produced for applications such as air pollution studies, atmospheric disturbance monitoring, and military weapons targeting.

Hutchinson, Donald P. (Knoxville, TN)

1998-01-01T23:59:59.000Z

268

Widely tuneable scattering-type scanning near-field optical microscopy using pulsed quantum cascade lasers  

SciTech Connect (OSTI)

We demonstrate the use of a pulsed quantum cascade laser, wavelength tuneable between 6 and 10??m, with a scattering-type scanning near-field optical microscope (s-SNOM). A simple method for calculating the signal-to-noise ratio (SNR) of the s-SNOM measurement is presented. For pulsed lasers, the SNR is shown to be highly dependent on the degree of synchronization between the laser pulse and the sampling circuitry; in measurements on a gold sample, the SNR is 26 with good synchronization and less than 1 without. Simulations and experimental s-SNOM images, with a resolution of 100?nm, corresponding to ?/80, and an acquisition time of less than 90 s, are presented as proof of concept. They show the change in the field profile of plasmon-resonant broadband antennas when they are excited with wavelengths of 7.9 and 9.5??m.

Yoxall, Edward, E-mail: edward.yoxall@imperial.ac.uk; Rahmani, Mohsen; Maier, Stefan A.; Phillips, Chris C. [The Blackett Laboratory, Department of Physics, Imperial College London, London SW7 2AZ (United Kingdom)] [The Blackett Laboratory, Department of Physics, Imperial College London, London SW7 2AZ (United Kingdom); Navarro-Cía, Miguel [Optical and Semiconductor Devices Group, Department of Electrical and Electronic Engineering, Imperial College London, London SW7 2BT (United Kingdom)] [Optical and Semiconductor Devices Group, Department of Electrical and Electronic Engineering, Imperial College London, London SW7 2BT (United Kingdom)

2013-11-18T23:59:59.000Z

269

First High-resolution Spectroscopic Observations of an Erupting Prominence Within a Coronal Mass Ejection by the Interface Region Imaging Spectrograph (IRIS)  

E-Print Network [OSTI]

Spectroscopic observations of prominence eruptions associated with coronal mass ejections (CMEs), although relatively rare, can provide valuable plasma and 3D geometry diagnostics. We report the first observations by the Interface Region Imaging Spectrograph (IRIS) mission of a spectacular fast CME/prominence eruption associated with an equivalent X1.6 flare on 2014 May 9. The maximum plane-of-sky and Doppler velocities of the eruption are 1200 and 460 km/s, respectively. There are two eruption components separated by ~200 km/s in Doppler velocity: a primary, bright component and a secondary, faint component, suggesting a hollow, rather than solid, cone-shaped distribution of material. The eruption involves a left-handed helical structure undergoing counter-clockwise (viewed top-down) unwinding motion. There is a temporal evolution from upward eruption to downward fallback with less-than-free-fall speeds and decreasing nonthermal line widths. We find a wide range of Mg II k/h line intensity ratios (less than ...

Liu, Wei; Vial, Jean-Claude; Title, Alan M; Carlsson, Mats; Uitenbroek, Han; Okamoto, Takenori J; Berger, Thomas E; Antolin, Patrick

2015-01-01T23:59:59.000Z

270

A new compact, high sensitivity neutron imaging system  

SciTech Connect (OSTI)

We have developed a new small neutron imaging system (SNIS) diagnostic for the OMEGA laser facility. The SNIS uses a penumbral coded aperture and has been designed to record images from low yield (10{sup 9}-10{sup 10} neutrons) implosions such as those using deuterium as the fuel. This camera was tested at OMEGA in 2009 on a rugby hohlraum energetics experiment where it recorded an image at a yield of 1.4 Multiplication-Sign 10{sup 10}. The resolution of this image was 54 {mu}m and the camera was located only 4 meters from target chamber centre. We recently improved the instrument by adding a cooled CCD camera. The sensitivity of the new camera has been fully characterized using a linear accelerator and a {sup 60}Co {gamma}-ray source. The calibration showed that the signal-to-noise ratio could be improved by using raw binning detection.

Caillaud, T.; Landoas, O.; Briat, M.; Rosse, B.; Thfoin, I.; Philippe, F.; Casner, A.; Bourgade, J. L.; Disdier, L. [CEA, DAM, DIF,F-91297 Arpajon (France); Glebov, V. Yu.; Marshall, F. J.; Sangster, T. C. [Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623-1299 (United States); Park, H. S.; Robey, H. F.; Amendt, P. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

2012-10-15T23:59:59.000Z

271

Application of soft X-ray lasers for probing high density plasmas  

SciTech Connect (OSTI)

The reliability and characteristics of collisionally pumped soft x-ray lasers make them ideal for a wide variety of plasma diagnostics. These systems now operate over a wavelength range extending from 35 to 400 {Angstrom} and have output energies as high as 10 mJ in 150 ps pulses. The beam divergence of these lasers is less than 15 mrad and they have a typical linewidth of {Delta}{lambda}/{lambda} {approximately} 10{sup -4} making them the brightest xuv sources available. In this paper we will describe the use of x-ray lasers to probe high density plasmas using a variety of diagnostic techniques. Using an x-ray laser and a multilayer mirror imaging system we have studied hydrodynamic imprinting of laser speckle pattern on directly driven thin foils with 1-2 {mu}m spatial resolution. Taking advantage of recently developed multilayer beamsplitters we have constructed and used a Mach-Zehnder interferometer operating at 155 {Angstrom} to probe 1-3 mm size laser produced plasmas with peak electron densities of 4 x 10{sup 21} cm{sup -3}. A comparison of our results with computer simulations will be presented.

Da Silva, L.B.; Barbee, T.W. Jr.; Cauble, R. [and others

1996-08-01T23:59:59.000Z

272

Restoring functional PET Images using Anatomical MR Images  

E-Print Network [OSTI]

Restoring functional PET Images using Anatomical MR Images Peter Philipsen, Ulrik Kjems, Peter Toft signal to noise ratio and the low spa­ tial resolution in Positron Emission Tomography (PET) images ? And Positron Emission Tomography (PET) Images? ffl Segmentation of MR Images ­ Extraction of important edges

Mosegaard, Klaus

273

Page 1Laser Safety Training Laser Institute of America Laser Safety Laser Institute of America  

E-Print Network [OSTI]

Page 1Laser Safety Training © Laser Institute of America 1 Laser Safety © Laser Institute of America Laser Safety: Hazards, Bioeffects, and Control Measures Laser Institute of America Gus Anibarro Education Manager 2Laser Safety © Laser Institute of America Laser Safety Overview Laser Safety Accidents

Farritor, Shane

274

Laser Telecommunication timeLaser beam  

E-Print Network [OSTI]

Laser Telecommunication Experiment Laser time Laser beam intensity timeLaser beam Laser battery Laser connected to a circuit without a modulator. Bottom graph illustrates what happen when a modulating signal is superimposed to the DC voltage driving the laser Laser beam intensity DC Input voltage DC

La Rosa, Andres H.

275

LANL's ChemCam conducts first laser test over the weekend | National...  

National Nuclear Security Administration (NNSA)

This composite image, with magnified insets, depicts the first laser test by the Chemistry and Camera, or ChemCam, instrument aboard NASA's Curiosity Mars rover. Image credit:...

276

Near-electrode imager  

DOE Patents [OSTI]

An apparatus, near-electrode imager, for employing nuclear magnetic resonance imaging to provide in situ measurements of electrochemical properties of a sample as a function of distance from a working electrode. The near-electrode imager uses the radio frequency field gradient within a cylindrical toroid cavity resonator to provide high-resolution nuclear magnetic resonance spectral information on electrolyte materials.

Rathke, Jerome W. (Lockport, IL); Klingler, Robert J. (Westmont, IL); Woelk, Klaus (Wachtberg, DE); Gerald, II, Rex E. (Brookfield, IL)

2000-01-01T23:59:59.000Z

277

Laser microphone  

DOE Patents [OSTI]

A microphone for detecting sound pressure waves includes a laser resonator having a laser gain material aligned coaxially between a pair of first and second mirrors for producing a laser beam. A reference cell is disposed between the laser material and one of the mirrors for transmitting a reference portion of the laser beam between the mirrors. A sensing cell is disposed between the laser material and one of the mirrors, and is laterally displaced from the reference cell for transmitting a signal portion of the laser beam, with the sensing cell being open for receiving the sound waves. A photodetector is disposed in optical communication with the first mirror for receiving the laser beam, and produces an acoustic signal therefrom for the sound waves.

Veligdan, James T. (Manorville, NY)

2000-11-14T23:59:59.000Z

278

Analysis of head pose, faces, and eye dynamics in images and videos : a multilevel framework and algorithms  

E-Print Network [OSTI]

resolution image from multiple low-resolution sam- ples,images can also be reconstructed using un-occluded training sam-

Wu, Junwen

2007-01-01T23:59:59.000Z

279

High-resolution 18F-FDG PET with MRI for monitoring response to treatment in rheumatoid arthritis  

E-Print Network [OSTI]

of a dedicated breast PET/CT scanner during human imaging. Jhigh-resolution 18 F-FDG PET images (pseudocolor) overlaidMONTH High-resolution 18 F-FDG PET with MRI for monitoring

2010-01-01T23:59:59.000Z

280

Laser Pointer System Intuitive Interaction for Large High-Res Displays  

E-Print Network [OSTI]

Laser Pointer System Intuitive Interaction for Large High-Res Displays LEDs Accelerometer Vibration Buttons Laser & LEDs Unlike conventional input devices like mouse and keyboard, laser pointers do that are displayed on large high-resolution screens. The laser pointer technology was developed in cooperation

Reiterer, Harald

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Approaching attometer laser vibrometry  

SciTech Connect (OSTI)

The heterodyne two-beam interferometer has been proven to be the optimal solution for laser-Doppler vibrometry regarding accuracy and signal robustness. The theoretical resolution limit for a two-beam interferometer of laser class 3R (up to 5 mW visible measurement-light) is in the regime of a few femtometer per square-root Hertz and well suited to study vibrations in microstructures. However, some new applications of RF-MEM resonators, nanostructures, and surface-nano-defect detection require resolutions beyond that limit. The resolution depends only on the noise and the sensor sensitivity to specimen displacements. The noise is already defined in nowadays systems by the quantum nature of light for a properly designed optical sensor and more light would lead to an inacceptable influence like heating of a very tiny structure. Thus, noise can only be improved by squeezed-light techniques which require a negligible loss of measurement light which is impossible for almost all technical measurement tasks. Thus, improving the sensitivity is the only possible path which could make attometer laser vibrometry possible. Decreasing the measurement wavelength would increase the sensitivity but would also increase the photon shot noise. In this paper, we discuss an approach to increase the sensitivity by assembling an additional mirror between interferometer and specimen to form an optical cavity. A detailed theoretical analysis of this setup is presented and we derive the resolution limit, discuss the main contributions to the uncertainty budget, and show a first experiment proving the sensitivity amplification of our approach.

Rembe, Christian; Kadner, Lisa; Giesen, Moritz [Research and Development, Polytec GmbH, Polytec Platz 1-7, 76337 Waldbronn (Germany)

2014-05-27T23:59:59.000Z

282

A fast microchannel plate-scintillator detector for velocity map imaging and imaging mass spectrometry  

SciTech Connect (OSTI)

The time resolution achievable using standard position-sensitive ion detectors, consisting of a chevron pair of microchannel plates coupled to a phosphor screen, is primarily limited by the emission lifetime of the phosphor, around 70 ns for the most commonly used P47 phosphor. We demonstrate that poly-para-phenylene laser dyes may be employed extremely effectively as scintillators, exhibiting higher brightness and much shorter decay lifetimes than P47. We provide an extensive characterisation of the properties of such scintillators, with a particular emphasis on applications in velocity-map imaging and microscope-mode imaging mass spectrometry. The most promising of the new scintillators exhibits an electron-to-photon conversion efficiency double that of P47, with an emission lifetime an order of magnitude shorter. The new scintillator screens are vacuum stable and show no signs of signal degradation even over longer periods of operation.

Winter, B.; King, S. J.; Vallance, C., E-mail: claire.vallance@chem.ox.ac.uk [Department of Chemistry, Chemistry Research Laboratory, University of Oxford, 12 Mansfield Rd, Oxford OX1 3TA (United Kingdom); Brouard, M., E-mail: mark.brouard@chem.ox.ac.uk [Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Rd, Oxford OX1 3QZ (United Kingdom)

2014-02-15T23:59:59.000Z

283

Real-time high-resolution X-ray imaging and nuclear magnetic resonance study of the hydration of pure and Na-doped C3A in the presence of sulfates  

SciTech Connect (OSTI)

This study details the differences in real-time hydration between pure tricalcium aluminate (cubic C{sub 3}A or 3CaO {center_dot} Al{sub 2}O{sub 3}) and Na-doped tricalcium aluminate (orthorhombic C{sub 3}A or Na{sub 2}Ca{sub 8}Al{sub 6}O{sub 18}), in aqueous solutions containing sulfate ions. Pure phases were synthesized in the laboratory to develop an independent benchmark for the reactions, meaning that their reactions during hydration in a simulated early age cement pore solution (saturated with respect to gypsum and lime) were able to be isolated. Because the rate of this reaction is extremely rapid, most microscopy methods are not adequate to study the early phases of the reactions in the early stages. Here, a high-resolution full-field soft X-ray imaging technique operating in the X-ray water window, combined with solution analysis by {sup 27}Al nuclear magnetic resonance (NMR) spectroscopy, was used to capture information regarding the mechanism of C{sub 3}A hydration during the early stages. There are differences in the hydration mechanism between the two types of C{sub 3}A, which are also dependent on the concentration of sulfate ions in the solution. The reactions with cubic C{sub 3}A (pure) seem to be more influenced by higher concentrations of sulfate ions, forming smaller ettringite needles at a slower pace than the orthorhombic C{sub 3}A (Na-doped) sample. The rate of release of aluminate species into the solution phase is also accelerated by Na doping.

Kirchheim,, A. P.; Dal Molin, D.C.; Emwas, Abdul-Hamid; Provis, J.L.; Fischer, P.; Monteiro, P.J.M.

2010-12-01T23:59:59.000Z

284

Seismic Imaging and Monitoring  

SciTech Connect (OSTI)

I give an overview of LANL's capability in seismic imaging and monitoring. I present some seismic imaging and monitoring results, including imaging of complex structures, subsalt imaging of Gulf of Mexico, fault/fracture zone imaging for geothermal exploration at the Jemez pueblo, time-lapse imaging of a walkway vertical seismic profiling data for monitoring CO{sub 2} inject at SACROC, and microseismic event locations for monitoring CO{sub 2} injection at Aneth. These examples demonstrate LANL's high-resolution and high-fidelity seismic imaging and monitoring capabilities.

Huang, Lianjie [Los Alamos National Laboratory

2012-07-09T23:59:59.000Z

285

Investigations into ultraviolet matrix-assisted laser desorption  

SciTech Connect (OSTI)

Matrix-assisted laser desorption (MALD) is a technique for converting large biomolecules into gas phase ions. Some characteristics of the commonly used uv matrices are determined. Solubilities in methanol range from 0.1 to 0.5 M. Solid phase absorption spectra are found to be similar to solution, but slightly red-shifted. Acoustic and quartz crystal microbalance signals are investigated as possible means of uv-MALD quantitation. Evidence for the existence of desorption thresholds is presented. Threshold values are determined to be in the range of 2 to 3 MW/cm{sup 2}. A transient imaging technique based on laser-excited fluorescence for monitoring MALD plumes is described. Sensitivity is well within the levels required for studying matrix-assisted laser desorption, where analyte concentrations are significantly lower than those in conventional laser desorption. Results showing the effect of film morphology, particularly film thickness, on plume dynamics are presented. In particular, MALD plumes from thicker films tend to exhibit higher axial velocities. Fluorescent labeling of protein and of DNA is used to allow imaging of their uv-MALD generated plumes. Integrated concentrations are available with respect to time, making it possible to assess the rate of fragmentation. The spatial and temporal distributions are important for the design of secondary ionization schemes to enhance ion yields and for the optimization of ion collection in time-of-flight MS instruments to maximize resolution. Such information could also provide insight into whether ionization is closely associated with the desorption step or whether it is a result of subsequent collisions with the matrix gas (e.g., proton transfer). Although the present study involves plumes in a normal atmosphere, adaptation to measurements in vacuum (e.g., inside a mass spectrometer) should be straightforward.

Heise, T.W.

1993-07-01T23:59:59.000Z

286

Summary Report of Working Group 6: Laser-Plasma Acceleration  

E-Print Network [OSTI]

be an important focus of laser-plasma acceleration researchfocus. In both cases, light regions of the image ionized and heated the plasma,

Leemans, Wim P.; Downer, Michael; Siders, Craig

2008-01-01T23:59:59.000Z

287

High resolution x-ray microscope  

SciTech Connect (OSTI)

The authors present x-ray images of grid meshes and biological material obtained using a microspot x-ray tube with a multilayer optic and a 92-element parabolic compound refractive lens (CRL) made of a plastic containing only hydrogen and carbon. Images obtained using this apparatus are compared with those using an area source with a spherical lens and a spherical lens with multilayer condenser. The authors found the best image quality using the multilayer condenser with a parabolic lens, compared to images with a spherical lens and without the multilayer optics. The resolution was measured using a 155-element parabolic CRL and a multilayer condenser with the microspot tube. The experiment demonstrates about 1.1 {mu}m resolution.

Gary, C. K.; Park, H.; Lombardo, L. W.; Piestrup, M. A.; Cremer, J. T.; Pantell, R. H.; Dudchik, Y. I. [Adelphi Technology, Inc. 981-B Industrial Road, San Carlos, California 94070 (United States); Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States); Institute of Applied Physics Problems, Kurchatova 7, Minsk 220064 (Belarus)

2007-04-30T23:59:59.000Z

288

Ultrafast electron beam imaging of femtosecond laser-induced plasma Junjie Li, Xuan Wang, Zhaoyang Chen, Richard Clinite, Samuel S. Mao et al.  

E-Print Network [OSTI]

, Beijing 100190, China and Department of Physics, Shanghai Jiao Tong University, Shanghai 200240, China in the early stage of laser ablation of a copper target are investigated in real time by making ultrafast have been a subject of intensive investigation in recent years ow- ing to its importance in a wide

Cao, Jianming

289

Fluorescent image tracking velocimeter  

DOE Patents [OSTI]

A multiple-exposure fluorescent image tracking velocimeter (FITV) detects and measures the motion (trajectory, direction and velocity) of small particles close to light scattering surfaces. The small particles may follow the motion of a carrier medium such as a liquid, gas or multi-phase mixture, allowing the motion of the carrier medium to be observed, measured and recorded. The main components of the FITV include: (1) fluorescent particles; (2) a pulsed fluorescent excitation laser source; (3) an imaging camera; and (4) an image analyzer. FITV uses fluorescing particles excited by visible laser light to enhance particle image detectability near light scattering surfaces. The excitation laser light is filtered out before reaching the imaging camera allowing the fluoresced wavelengths emitted by the particles to be detected and recorded by the camera. FITV employs multiple exposures of a single camera image by pulsing the excitation laser light for producing a series of images of each particle along its trajectory. The time-lapsed image may be used to determine trajectory and velocity and the exposures may be coded to derive directional information.

Shaffer, Franklin D. (Library, PA)

1994-01-01T23:59:59.000Z

290

Target isolation system, high power laser and laser peening method and system using same  

DOE Patents [OSTI]

A system for applying a laser beam to work pieces, includes a laser system producing a high power output beam. Target delivery optics are arranged to deliver the output beam to a target work piece. A relay telescope having a telescope focal point is placed in the beam path between the laser system and the target delivery optics. The relay telescope relays an image between an image location near the output of the laser system and an image location near the target delivery optics. A baffle is placed at the telescope focal point between the target delivery optics and the laser system to block reflections from the target in the target delivery optics from returning to the laser system and causing damage.

Dane, C. Brent (Livermore, CA); Hackel, Lloyd A. (Livermore, CA); Harris, Fritz (Rocklin, CA)

2007-11-06T23:59:59.000Z

291

Continuous wave laser irradiation of explosives  

SciTech Connect (OSTI)

Quantitative measurements of the levels of continuous wave (CW) laser light that can be safely applied to bare explosives during contact operations were obtained at 532 nm, 785 nm, and 1550 nm wavelengths. A thermal camera was used to record the temperature of explosive pressed pellets and single crystals while they were irradiated using a measured laser power and laser spot size. A visible light image of the sample surface was obtained before and after the laser irradiation. Laser irradiation thresholds were obtained for the onset of any visible change to the explosive sample and for the onset of any visible chemical reaction. Deflagration to detonation transitions were not observed using any of these CW laser wavelengths on single crystals or pressed pellets in the unconfined geometry tested. Except for the photochemistry of DAAF, TATB and PBX 9502, all reactions appeared to be thermal using a 532 nm wavelength laser. For a 1550 nm wavelength laser, no photochemistry was evident, but the laser power thresholds for thermal damage in some of the materials were significantly lower than for the 532 nm laser wavelength. No reactions were observed in any of the studied explosives using the available 300 mW laser at 785 nm wavelength. Tables of laser irradiance damage and reaction thresholds are presented for pressed pellets of PBX9501, PBX9502, Composition B, HMX, TATB, RDX, DAAF, PETN, and TNT and single crystals of RDX, HMX, and PETN for each of the laser wavelengths.

McGrane, Shawn D.; Moore, David S.

2010-12-01T23:59:59.000Z

292

Protective laser beam viewing device  

DOE Patents [OSTI]

A protective laser beam viewing system or device including a camera selectively sensitive to laser light wavelengths and a viewing screen receiving images from the laser sensitive camera. According to a preferred embodiment of the invention, the camera is worn on the head of the user or incorporated into a goggle-type viewing display so that it is always aimed at the area of viewing interest to the user and the viewing screen is incorporated into a video display worn as goggles over the eyes of the user.

Neil, George R.; Jordan, Kevin Carl

2012-12-18T23:59:59.000Z

293

Imaging with Scattered Neutrons  

E-Print Network [OSTI]

We describe a novel experimental technique for neutron imaging with scattered neutrons. These scattered neutrons are of interest for condensed matter physics, because they permit to reveal the local distribution of incoherent and coherent scattering within a sample. In contrast to standard attenuation based imaging, scattered neutron imaging distinguishes between the scattering cross section and the total attenuation cross section including absorption. First successful low-noise millimeter-resolution images by scattered neutron radiography and tomography are presented.

H. Ballhausen; H. Abele; R. Gaehler; M. Trapp; A. Van Overberghe

2006-10-30T23:59:59.000Z

294

Photothermal imaging scanning microscopy  

DOE Patents [OSTI]

Photothermal Imaging Scanning Microscopy produces a rapid, thermal-based, non-destructive characterization apparatus. Also, a photothermal characterization method of surface and subsurface features includes micron and nanoscale spatial resolution of meter-sized optical materials.

Chinn, Diane (Pleasanton, CA); Stolz, Christopher J. (Lathrop, CA); Wu, Zhouling (Pleasanton, CA); Huber, Robert (Discovery Bay, CA); Weinzapfel, Carolyn (Tracy, CA)

2006-07-11T23:59:59.000Z

295

Overview of the ARGOS X-ray framing camera for Laser MegaJoule  

SciTech Connect (OSTI)

Commissariat à l’Énergie Atomique et aux Énergies Alternatives has developed the ARGOS X-ray framing camera to perform two-dimensional, high-timing resolution imaging of an imploding target on the French high-power laser facility Laser MegaJoule. The main features of this camera are: a microchannel plate gated X-ray detector, a spring-loaded CCD camera that maintains proximity focus in any orientation, and electronics packages that provide remotely-selectable high-voltages to modify the exposure-time of the camera. These components are integrated into an “air-box” that protects them from the harsh environmental conditions. A miniaturized X-ray generator is also part of the device for in situ self-testing purposes.

Trosseille, C., E-mail: clement.trosseille@cea.fr; Aubert, D.; Auger, L.; Bazzoli, S.; Brunel, P.; Burillo, M.; Chollet, C.; Jasmin, S.; Maruenda, P.; Moreau, I.; Oudot, G.; Raimbourg, J.; Soullié, G.; Stemmler, P.; Zuber, C. [CEA, DAM, DIF, F-91297 Arpajon (France); Beck, T. [CEA, DEN, CADARACHE, F-13108 St Paul lez Durance (France); Gazave, J. [CEA, DAM, CESTA, F-33116 Le Barp (France)

2014-11-15T23:59:59.000Z

296

Laser ignition  

DOE Patents [OSTI]

In the apparatus of the invention, a first excitation laser or other excitation light source capable of producing alternating beams of light having different wavelengths is used in tandem with one or more ignitor lasers to provide a compact, durable, engine deployable fuel ignition laser system. Reliable fuel ignition is provided over a wide range of fuel conditions by using the single remote excitation light source for pumping one or more small lasers located proximate to one or more fuel combustion zones with alternating wavelengths of light.

Early, James W. (Los Alamos, NM); Lester, Charles S. (San Juan Pueblo, NM)

2002-01-01T23:59:59.000Z

297

E-Print Network 3.0 - assessment imaging issues Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

the super-resolution (SR) of images and video... . The term SR is used to describe the process of obtaining a high-resolution (HR) image, or a sequence of HR... images, from a set...

298

Lensless X-Ray Imaging in Reflection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Imaging in Reflection Print The advent of x-ray free-electron laser (XFEL) light sources has led to an outburst of research activities in the field of lensless imaging. XFELs...

299

Lensless X-Ray Imaging in Reflection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Lensless X-Ray Imaging in Reflection Lensless X-Ray Imaging in Reflection Print Wednesday, 26 October 2011 00:00 The advent of x-ray free-electron laser (XFEL) light sources has...

300

Data disaggregation and evapotranspiration modeling: a synergism between multi-spectral/multi-resolution remote sensing data  

E-Print Network [OSTI]

resolution Imaging Spectroradiometer), respectively. - SEB-1S is a mono-source surface energy balance model-resolution remote sensing data, United States (2013)" #12; transpiration (T). The surface albedo (SA) derived from shortwave reflectances modulates the available energy

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Conflict Resolution Day  

Broader source: Energy.gov [DOE]

Conflict Resolution Day takes a look at mediation, conciliation, negotiation, arbitration, the ombudsman, and facilitation to resolve conflict in the workplace. Employees and contractors are...

302

Laser Scanner Demonstration  

SciTech Connect (OSTI)

In the Summer of 2004 a request for proposals went out to potential vendors to offer a three-dimensional laser scanner for a number of unique metrology tasks at the Stanford Linear Accelerator Center (SLAC). Specifications were established including range, accuracy, scan density, resolution and field of view in consideration of anticipated department requirements. Four vendors visited the site to present their system and they were asked to perform three unique tests with their system on a two day visit to SLAC. Two of the three tests were created to emulate real-world applications at SLAC while the third was an accuracy and resolution series of experiments. The scope of these tests is presented and some of the vendor's results are included.

Fuss, B.

2005-09-06T23:59:59.000Z

303

Using X-ray free-electron lasers for probing of complex interaction dynamics of ultra-intense lasers with solid matter  

SciTech Connect (OSTI)

We demonstrate the potential of X-ray free-electron lasers (XFEL) to advance the understanding of complex plasma dynamics by allowing for the first time nanometer and femtosecond resolution at the same time in plasma diagnostics. Plasma phenomena on such short timescales are of high relevance for many fields of physics, in particular in the ultra-intense ultra-short laser interaction with matter. Highly relevant yet only partially understood phenomena become directly accessible in experiment. These include relativistic laser absorption at solid targets, creation of energetic electrons and electron transport in warm dense matter, including the seeding and development of surface and beam instabilities, ambipolar expansion, shock formation, and dynamics at the surfaces or at buried layers. In this paper, we focus on XFEL plasma probing for high power laser matter interactions based on quantitative calculations using synthesized data and evaluate the feasibility of various imaging and scattering techniques with special focus on the small angle X-ray scattering technique.

Kluge, T., E-mail: t.kluge@hzdr.de; Huang, L. G.; Metzkes, J.; Bussmann, M. [Helmholtz-Zentrum Dresden-Rossendorf e.V., D-01328 Dresden (Germany)] [Helmholtz-Zentrum Dresden-Rossendorf e.V., D-01328 Dresden (Germany); Gutt, C. [Universität Siegen, D-57068 Siegen (Germany)] [Universität Siegen, D-57068 Siegen (Germany); Schramm, U.; Cowan, T. E. [Helmholtz-Zentrum Dresden-Rossendorf e.V., D-01328 Dresden (Germany) [Helmholtz-Zentrum Dresden-Rossendorf e.V., D-01328 Dresden (Germany); Technische Universität Dresden, D-01062 Dresden (Germany)

2014-03-15T23:59:59.000Z

304

High-resolution laser spectroscopy between 0.9 and 14.3 THz in a supersonic beam: Rydberg-Rydberg transitions of atomic Xe at intermediate n values  

SciTech Connect (OSTI)

A laser-based, pulsed, narrow-band source of submillimeter-wave radiation has been developed that is continuously tunable from 0.1 THz to 14.3 THz. The source is based on difference-frequency mixing in the nonlinear crystal trans-4{sup Prime }-(dimethylamino)-N-methyl-4-stilbazolium tosylate. By varying the pulse length, the bandwidth of the submillimeter-wave radiation can be adjusted between 85 MHz and 2.8 MHz. This new radiation source has been integrated in a vacuum-ultraviolet-submillimeter-ware double-resonance spectrometer, with which low-frequency transitions of atoms and molecules in supersonic beams can be detected mass-selectively by photoionization and time-of-flight mass spectrometry. The properties of the radiation source and spectrometer are demonstrated in a study of 33f Leftwards-Arrow nd Rydberg-Rydberg transitions in Xe with n in the range 16-31. The frequency calibration of the submillimeter-wave radiation was performed with an accuracy of 2.8 MHz. The narrowest lines observed experimentally have a full-width at half-maximum of {approx}3 MHz, which is sufficient to fully resolve the hyperfine structure of the Rydberg-Rydberg transitions of {sup 129}Xe and {sup 131}Xe. A total of 72 transitions were measured in the range between 0.937 THz and 14.245 THz and their frequencies are compared with frequencies calculated by multichannel quantum defect theory.

Haase, Christa; Agner, Josef A.; Merkt, Frederic [Laboratorium fuer Physikalische Chemie, ETH Zuerich, 8093 Zuerich (Switzerland)

2013-06-28T23:59:59.000Z

305

atomic resolution crystal: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Crystal structure retrieval by maximum entropy analysis of atomic resolution incoherent images Materials Science Websites...

306

angstrom resolution crystal: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Muller, David A; 10.1103PhysRevB.86.195415 2012-01-01 5 Crystal structure retrieval by maximum entropy analysis of atomic resolution incoherent images Materials Science Websites...

307

Active imaging system with Faraday filter  

DOE Patents [OSTI]

An active imaging system has a low to medium powered laser transmitter and receiver wherein the receiver includes a Faraday filter with an ultranarrow optical bandpass and a bare (nonintensified) CCD camera. The laser is locked in the vicinity of the passband of the Faraday filter. The system has high sensitivity to the laser illumination while eliminating solar background.

Snyder, J.J.

1993-04-13T23:59:59.000Z

308

Beam transport and monitoring for laser plasma accelerators  

SciTech Connect (OSTI)

The controlled transport and imaging of relativistic electron beams from laser plasma accelerators (LPAs) are critical for their diagnostics and applications. Here we present the design and progress in the implementation of the transport and monitoring system for an undulator based electron beam diagnostic. Miniature permanent-magnet quadrupoles (PMQs) are employed to realize controlled transport of the LPA electron beams, and cavity based electron beam position monitors for non-invasive beam position detection. Also presented is PMQ calibration by using LPA electron beams with broadband energy spectrum. The results show promising performance for both transporting and monitoring. With the proper transport system, XUV-photon spectra from THUNDER will provide the momentum distribution of the electron beam with the resolution above what can be achieved by the magnetic spectrometer currently used in the LOASIS facility.

Nakamura, K.; Sokollik, T.; Tilborg, J. van; Gonsalves, A. J.; Shaw, B.; Shiraishi, S.; Mittal, R.; De Santis, S.; Byrd, J. M.; Leemans, W. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States) and University of California, Berkeley, CA 94720 (United States)

2012-12-21T23:59:59.000Z

309

Laser device  

DOE Patents [OSTI]

A laser device includes a virtual source configured to aim laser energy that originates from a true source. The virtual source has a vertical rotational axis during vertical motion of the virtual source and the vertical axis passes through an exit point from which the laser energy emanates independent of virtual source position. The emanating laser energy is collinear with an orientation line. The laser device includes a virtual source manipulation mechanism that positions the virtual source. The manipulation mechanism has a center of lateral pivot approximately coincident with a lateral index and a center of vertical pivot approximately coincident with a vertical index. The vertical index and lateral index intersect at an index origin. The virtual source and manipulation mechanism auto align the orientation line through the index origin during virtual source motion.

Scott, Jill R. (Idaho Falls, ID); Tremblay, Paul L. (Idaho Falls, ID)

2008-08-19T23:59:59.000Z

310

7 Å Resolution in Protein 2-Dimentional-Crystal X-Ray Diffraction at Linac Coherent Light Source  

SciTech Connect (OSTI)

Membrane proteins arranged as two-dimensional (2D) crystals in the lipid en- vironment provide close-to-physiological structural information, which is essential for understanding the molecular mechanisms of protein function. X-ray diffraction from individual 2D crystals did not represent a suitable investigation tool because of radiation damage. The recent availability of ultrashort pulses from X-ray Free Electron Lasers (X-FELs) has now provided a mean to outrun the damage. Here we report on measurements performed at the LCLS X-FEL on bacteriorhodopsin 2D crystals mounted on a solid support and kept at room temperature. By merg- ing data from about a dozen of single crystal diffraction images, we unambiguously identified the diffraction peaks to a resolution of 7 °A, thus improving the observable resolution with respect to that achievable from a single pattern alone. This indicates that a larger dataset will allow for reliable quantification of peak intensities, and in turn a corresponding increase of resolution. The presented results pave the way to further X-FEL studies on 2D crystals, which may include pump-probe experiments at subpicosecond time resolution.

Pedrini, Bill; Tsai, Ching-Ju; Capitani, Guido; Padeste, Celestino; Hunter, Mark; Zatsepin, Nadia A.; Barty, Anton; Benner, Henry; Boutet, Sebastien; Feld, Geoffrey K.; Hau-Riege, Stefan; Kirian, Rick; Kupitz, Christopher; Messerschmidt, Marc; Ogren, John I.; Pardini, Tommaso; Segelke, Brent; Williams, Garth J.; Spence , John C.; Abela, Rafael; Coleman, Matthew A.; Evans, James E.; Schertler, Gebhard; Frank, Matthias; Li, Xiao-Dan

2014-06-09T23:59:59.000Z

311

DOE-Imaging grant FG02-06ER15829, entitled "Developing Laser-Induced Re-Collision Electron Self-Diffraction" Brief summary of accomplishments  

SciTech Connect (OSTI)

Our principal goal was the experimental demonstration of Laser-Induced Electron Diffraction (LIED). Key steps along the development of this experimental technique have been accomplished and reported in the publications listed in this brief report. We started with measuring 3D electron momenta spectra in aligned nitrogen and oxygen molecules. Chakra Maharjan (Ph.D. student of Lew Cocke) was a lead researcher on this project. Although Chakra succeeded in obtaining those spectra, we were scooped by the publication of identical results in Science by the NRC Ottawa group. Our results were never published as a refereed article, but became a part of Chakra's Ph.D. dissertation. That Science paper was the first experimental demonstration of Laser-Induced Electron Diffraction (LIED). Chakra also worked on wavelength dependence of 3D ATI spectra of atoms and molecules using tunable OPA pulses. Another Ph.D. student, Maia Magrakvelidze (her GRA was funded by the grant), started working on COLTRIMS experiments using OPA pulses (1800 nm wavelength). After some initial experiments it became apparent that COLTRIMS did not yield sufficient count rates of electrons in the high-energy part of the spectrum to see diffraction signatures with acceptable statistics (unfavorable scaling of the electron yield with laser wavelength was partly to blame). Nevertheless, Maia managed to use COLTRIMS and OPA to measure the angular dependence of the tunneling ionization rate in D{sub 2} molecules. Following the initial trial experiments, the decision was made to switch from COLTRIMS to VMI in order to increase the count rates by a factor of {approx}100, which may have given us a chance to see LIED. Research Associate Dr. Sankar De (his salary was funded by the grant), in collaboration with Matthias Kling's group (then at MPQ Garching), proceeded to design a special multi-electrode VMI spectrometer for capturing high-energy ATI electrons and to install it in place of COLTRIMS inside our experimental chamber. That apparatus was later used for the first demonstration of field-free orientation in CO using two-color laser pulses as well as for a series of other experiments, such as pump-probe studies of molecular dynamics with few-cycle laser pulses, control of electron localization in dissociating hydrogen molecules using two-color laser pulses, and ATI spectra of Xe ionized by two-color laser pulses. In parallel, Dipanwita Ray (Ph.D. student of Lew Cocke) worked on measuring angle-resolved ATI spectra of noble gases using a stereo-ATI phasemeter as a TOF electron spectrometer. She observed the angular diffraction structures in 3D ATI spectra of Ar, Kr and Xe, which were interpreted in terms of the Quantitative Rescattering theory newly developed by C.D. Lin. We also attempted to use a much more powerful OPA (five times more energy per pulse than the one we had at JRML) available at the Advanced Laser Light Source (ALLS) in Montreal to observe LIED. Two visits to ALLS by the PI, Igor Litvinyuk, and one visit by the PI's Ph.D. student (Irina Bocharova) were funded by the grant. Though we failed to observe LIED (the repetition rate of the ALLS OPA was too low at only 100 Hz), this international collaboration resulted in several publications on other related subjects, such as the wavelength dependence of laser Coulomb explosion of hydrogen, the wavelength dependence of non-sequential double ionization of neon and argon, the demonstration of charge-resonance enhanced ionization in CO{sub 2}, and the study of non-elastic scattering processes in H{sub 2}. Theoretical efforts to account for the hydrogen Coulomb explosion experiment resulted in another paper by Maia Magrakvelidze as lead author. Although for various reasons we failed to achieve our main goal of observing LIED, we salute the recent success in this endeavor by Lou DiMauro's group (with theoretical support from our KSU colleague C.D. Lin) published in Nature, which validates our approach.

Igor V. Litvinyuk, and Itzik Ben-Itzhak

2012-04-01T23:59:59.000Z

312

Wall and laser spot motion in cylindrical hohlraums  

SciTech Connect (OSTI)

Wall and laser spot motion measurements in empty, propane-filled and plastic (CH)-lined gold coated cylindrical hohlraums were performed on the Omega laser facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. Wall motion was measured using axial two-dimensional (2D) x-ray imaging and laser spot motion was perpendicularly observed through a thinned wall using streaked hard x-ray imaging. Experimental results and 2D hydrodynamic simulations show that while empty targets exhibit on-axis plasma collision, CH-lined and propane-filled targets inhibit wall expansion, corroborated with perpendicular streaked imaging showing a slower motion of laser spots.

Huser, G.; Courtois, C.; Monteil, M.-C. [CEA, DAM, DIF, F-91297 Arpajon (France)

2009-03-15T23:59:59.000Z

313

High resolution telescope including an array of elemental telescopes aligned along a common axis and supported on a space frame with a pivot at its geometric center  

DOE Patents [OSTI]

A large effective-aperture, low-cost optical telescope with diffraction-limited resolution enables ground-based observation of near-earth space objects. The telescope has a non-redundant, thinned-aperture array in a center-mount, single-structure space frame. It employes speckle interferometric imaging to achieve diffraction-limited resolution. The signal-to-noise ratio problem is mitigated by moving the wavelength of operation to the near-IR, and the image is sensed by a Silicon CCD. The steerable, single-structure array presents a constant pupil. The center-mount, radar-like mount enables low-earth orbit space objects to be tracked as well as increases stiffness of the space frame. In the preferred embodiment, the array has elemental telescopes with subaperture of 2.1 m in a circle-of-nine configuration. The telescope array has an effective aperture of 12 m which provides a diffraction-limited resolution of 0.02 arc seconds. Pathlength matching of the telescope array is maintained by a electro-optical system employing laser metrology. Speckle imaging relaxes pathlength matching tolerance by one order of magnitude as compared to phased arrays. Many features of the telescope contribute to substantial reduction in costs. These include eliminating the conventional protective dome and reducing on-site construction activities. The cost of the telescope scales with the first power of the aperture rather than its third power as in conventional telescopes. 15 figs.

Norbert, M.A.; Yale, O.

1992-04-28T23:59:59.000Z

314

Integration of photonic and passive microfluidic devices into lab-on-chip with femtosecond laser materials processing  

E-Print Network [OSTI]

Femtosecond laser materials processing is a powerful method for the integration of high resolution, 3D structures into Lab-On-Chip (LOC) systems. One major application of femtosecond laser materials processing is waveguide ...

Gu, Yu, Ph.D. Massachusetts Institute of Technology

2011-01-01T23:59:59.000Z

315

E-Print Network 3.0 - art noninvasive imaging Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

imaging methods are unable to characterize... and Otological Society, Inc. Imaging of the Pediatric Airway Using ... Source: Chen, Zhongping - Beckman Laser Institute and Medical...

316

Detailed modeling and laser-induced fluorescence imaging of nitric oxide in a NH3-seeded non-premixed methane/air flame  

E-Print Network [OSTI]

non-premixed methane/air flame John B. Bell, Marcus S. Day, Joseph F. Grcar Computing Sciences-induced fluorescence imaging of nitric oxide in a NH3-seeded non-premixed methane/air flame Abstract In this paper we study the formation of NO in laminar, nitrogen diluted methane diffusion flames that are seeded

Bell, John B.

317

Video Toroid Cavity Imager  

DOE Patents [OSTI]

A video toroid cavity imager for in situ measurement of electrochemical properties of an electrolytic material sample includes a cylindrical toroid cavity resonator containing the sample and employs NMR and video imaging for providing high-resolution spectral and visual information of molecular characteristics of the sample on a real-time basis. A large magnetic field is applied to the sample under controlled temperature and pressure conditions to simultaneously provide NMR spectroscopy and video imaging capabilities for investigating electrochemical transformations of materials or the evolution of long-range molecular aggregation during cooling of hydrocarbon melts. The video toroid cavity imager includes a miniature commercial video camera with an adjustable lens, a modified compression coin cell imager with a fiat circular principal detector element, and a sample mounted on a transparent circular glass disk, and provides NMR information as well as a video image of a sample, such as a polymer film, with micrometer resolution.

Gerald, Rex E. II; Sanchez, Jairo; Rathke, Jerome W.

2004-08-10T23:59:59.000Z

318

Laser goniometer  

DOE Patents [OSTI]

The laser goniometer is an apparatus which permits an operator to sight along a geologic feature and orient a collimated lamer beam to match the attitude of the feature directly. The horizontal orientation (strike) and the angle from horizontal (dip), are detected by rotary incremental encoders attached to the laser goniometer which provide a digital readout of the azimuth and tilt of the collimated laser beam. A microprocessor then translates the square wave signal encoder outputs into an ASCII signal for use by data recording equipment.

Fairer, George M. (Boulder, CO); Boernge, James M. (Lakewood, CO); Harris, David W. (Lakewood, CO); Campbell, DeWayne A. (Littleton, CO); Tuttle, Gene E. (Littleton, CO); McKeown, Mark H. (Golden, CO); Beason, Steven C. (Lakewood, CO)

1993-01-01T23:59:59.000Z

319

E-Print Network 3.0 - atomic resolution z-contrast Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Cambridge Collection: Materials Science 11 Spectroscopic Imaging of Single AtomsWithin a Bulk Solid S. D. Findlay,2 Summary: a high resolution Z-contrast image of a...

320

LASER ACCELERATORS  

E-Print Network [OSTI]

UNIVERSITY OF CALIFORNIA Accelerator & Fusion Researchat the 1983 Particle Accelerator Conference, Santa Fe, NM,March 21-23, 1983 LASER ACCELERATORS A.M. Sessler TWO-WEEK

Sessler, A.M.

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Laser barometer  

SciTech Connect (OSTI)

This paper describes an invention of a pressure measuring instrument which uses laser radiation to sense the pressure in an enclosed environment by means of measuring the change in refractive index of a gas - which is pressure dependent.

Abercrombie, K.R.; Shiels, D.; Rash, T.

1998-04-01T23:59:59.000Z

322

Laser Optomechanics  

E-Print Network [OSTI]

Cavity optomechanics explores the coupling between the optical field and the mechanical oscillation to induce cooling and regenerative oscillation in a mechanical oscillator. So far, optomechanics relies on the detuning between the cavity and an external pump laser, where the laser acts only as a power supply. Here, we report a new scheme with mutual coupling between a mechanical oscillator that supports a mirror of a vertical-cavity surface-emitting laser (VCSEL) and the optical field, greatly enhancing the light-matter energy transfer. In this work, we used an ultra-light-weight (130 pg) high-contrast-grating (HCG) mirror in a VCSEL, whose reflectivity spectrum is designed to facilitate strong optomechanical coupling, to demonstrate optomechanically-induced regenerative oscillation of the laser optomechanical cavity with > 550 nm self-oscillation amplitude of the micro-mechanical oscillator, two to three orders of magnitude larger than typical. This new scheme not only offers an efficient approach for high-...

Yang, Weijian; Ng, Kar Wei; Rao, Yi; Chase, Christopher; Chang-Hasnain, Connie J

2015-01-01T23:59:59.000Z

323

Neutron Imaging of Advanced Engine Technologies  

Broader source: Energy.gov (indexed) [DOE]

during a series of partial regenerations (9302012). - Achieved * Determine temporal and spatial resolution of neutron imaging with respect to fluid density and flow in fuel...

324

Neutron Imaging of Advanced Engine Technologies  

Broader source: Energy.gov (indexed) [DOE]

diesel injector: Filled reservoir Void in reservoir 6 Milestones * Determine temporal and spatial resolution of neutron imaging with respect to fluid density and flow in fuel...

325

Laser EYE SURGERY LASIK and Excimer Lasers  

E-Print Network [OSTI]

Laser EYE SURGERY LASIK and Excimer Lasers Michael Hutchins #12;The PROBLEM opia - near sightedness - Laser Assisted in SItu Keratomileusis atomileusis is the procedure of opening the eye and ring the cornea. SIK uses an excimer laser to perform the alterations an er a knife or a femtosecond laser

Fygenson, Deborah Kuchnir

326

Greenland Observed at High Resolution by the Seasat Scatterometer  

E-Print Network [OSTI]

Greenland Observed at High Resolution by the Seasat Scatterometer D.G. Long', P.J. Hardin2, and RA to SASS data for the study of Greenland's ice sheet. We present a time series of the radar backscatter images over Greenland covering the time period July-September 1978. The images provide an island

Long, David G.

327

Radiology utilizing a gas multiwire detector with resolution enhancement  

DOE Patents [OSTI]

This invention relates to a process and apparatus for obtaining filmless, radiological, digital images utilizing a gas multiwire detector. Resolution is enhanced through projection geometry. This invention further relates to imaging systems for X-ray examination of patients or objects, and is particularly suited for mammography.

Majewski, Stanislaw (Grafton, VA); Majewski, Lucasz A. (Grafton, VA)

1999-09-28T23:59:59.000Z

328

POLAR SEA-ICE CLASSIFICATION USING ENHANCED RESOLUTION NSCAT DATA  

E-Print Network [OSTI]

POLAR SEA-ICE CLASSIFICATION USING ENHANCED RESOLUTION NSCAT DATA Q. P. Remund and D. G. Long of the scatterometer image reconstruction with filter (SIRF) algorithm. SIRF produces images of A and B where A is U is shown to have high correlation with the NSIDC SSM/I derived multiyear ice maps. INTRODUCTION Polar sea

Long, David G.

329

Methods for increasing the sensitivity of gamma-ray imagers  

DOE Patents [OSTI]

Methods are presented that increase the position resolution and granularity of double sided segmented semiconductor detectors. These methods increase the imaging resolution capability of such detectors, either used as Compton cameras, or as position sensitive radiation detectors in imagers such as SPECT, PET, coded apertures, multi-pinhole imagers, or other spatial or temporal modulated imagers.

Mihailescu, Lucian (Pleasanton, CA); Vetter, Kai M. (Alameda, CA); Chivers, Daniel H. (Fremont, CA)

2012-02-07T23:59:59.000Z

330

Systems for increasing the sensitivity of gamma-ray imagers  

DOE Patents [OSTI]

Systems that increase the position resolution and granularity of double sided segmented semiconductor detectors are provided. These systems increase the imaging resolution capability of such detectors, either used as Compton cameras, or as position sensitive radiation detectors in imagers such as SPECT, PET, coded apertures, multi-pinhole imagers, or other spatial or temporal modulated imagers.

Mihailescu, Lucian; Vetter, Kai M.; Chivers, Daniel H.

2012-12-11T23:59:59.000Z

331

Method and apparatus for differential spectroscopic atomic-imaging using scanning tunneling microscopy  

DOE Patents [OSTI]

A Method and apparatus for differential spectroscopic atomic-imaging is disclosed for spatial resolution and imaging for display not only individual atoms on a sample surface, but also bonding and the specific atomic species in such bond. The apparatus includes a scanning tunneling microscope (STM) that is modified to include photon biasing, preferably a tuneable laser, modulating electronic surface biasing for the sample, and temperature biasing, preferably a vibration-free refrigerated sample mounting stage. Computer control and data processing and visual display components are also included. The method includes modulating the electronic bias voltage with and without selected photon wavelengths and frequency biasing under a stabilizing (usually cold) bias temperature to detect bonding and specific atomic species in the bonds as the STM rasters the sample. This data is processed along with atomic spatial topography data obtained from the STM raster scan to create a real-time visual image of the atoms on the sample surface.

Kazmerski, Lawrence L. (Lakewood, CO)

1990-01-01T23:59:59.000Z

332

Along the Laser Beampath  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

8 20 | Next | Last Back to Index NIF Laser Bay Each NIF laser bay is 122 meters (400 feet) long and contains 96 beamlines. This side view of Laser Bay 2 shows the four-high laser...

333

Laser Safety Introduction  

E-Print Network [OSTI]

Laser Safety #12;Introduction · A Laser is a device that controls the way energized atoms release photons. · LASER is an acronym for "Light Amplification by Stimulated Emission of Radiation" · The light emitted by a laser is non

McQuade, D. Tyler

334

X-ray tests of a two-dimensional stigmatic imaging scheme with variable magnifications  

SciTech Connect (OSTI)

A two-dimensional stigmatic x-ray imaging scheme, consisting of two spherically bent crystals, one concave and one convex, was recently proposed [M. Bitter et al., Rev. Sci. Instrum. 83, 10E527 (2012)]. The Bragg angles and the radii of curvature of the two crystals of this imaging scheme are matched to eliminate the astigmatism and to satisfy the Bragg condition across both crystal surfaces for a given x-ray energy. In this paper, we consider more general configurations of this imaging scheme, which allow us to vary the magnification for a given pair of crystals and x-ray energy. The stigmatic imaging scheme has been validated for the first time by imaging x-rays generated by a micro-focus x-ray source with source size of 8.4 ?m validated by knife-edge measurements. Results are presented from imaging the tungsten L?1 emission at 8.3976 keV, using a convex Si-422 crystal and a concave Si-533 crystal with 2d-spacings of 2.21707 Å and 1.65635 Å and radii of curvature of 500 ± 1 mm and 823 ± 1 mm, respectively, showing a spatial resolution of 54.9 ?m. This imaging scheme is expected to be of interest for the two-dimensional imaging of laser produced plasmas.

Lu, J., E-mail: jlu@pppl.gov [Key Laboratory of Optoelectronic Technology and System of Ministry of Education, Chongqing University, Chongqing 400030 (China); Bitter, M.; Hill, K. W.; Delgado-Aparicio, L. F.; Efthimion, P. C.; Pablant, N. A. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Beiersdorfer, P. [Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Caughey, T. A.; Brunner, J. [Inrad Optics, 181 Legrand Avenue, Northvale, New Jersey 07647 (United States)

2014-11-15T23:59:59.000Z

335

Quantitative x-ray imager (abstract)  

SciTech Connect (OSTI)

We report on development of a quantitative x-ray imager (QXI) for the national Inertial Confinement Fusion Program. Included in this development is a study of photocathode response as a function of photon energy, 2--17.5 keV, which is related to diagnostic development on the National Ignition Facility (NIF). The QXI is defined as being a quantative imager due to the repeated characterization. This instrument is systematically checked out, electronically as well as its photocathode x-ray response, both on a direct current and pulsed x-ray sources, before and after its use on a shot campaign. The QXI is a gated x-ray imager1 used for a variety of experiments conducted in the Inertial Confinement Fusion and Radiation Physics Program. The camera was assembled in Los Alamos and has been under development since 1997 and has now become the workhorse framing camera by the program. The electronics were built by Grant Applied Physics of San Fransisco, CA.2 The QXI has been used at the LANL Trident, LLNL Nova, and University of Rochester Laboratory OMEGA laser facilities. The camera consists of a grated microchannel plate (MCP), a phosphor coated fiberoptic faceplate coupled to film for data readout, along with high speed electronic pulsers to drive the x-ray detector. The QXI has both a two-strip and a four-strip detection head and has the ability to individually bias the gain of each of the strips. The timing of the QXI was done at the Trident short pulse laboratory, using 211 nm light. Single strip jitter was looked at as well and determined to be <25 ps. Flatfielding of the photocathode across the MCP was done with the Trident main laser with 150 J on a gold disk with a 1 ns. Spatial resolution was determined to be <5 {mu}m by using the same laser conditions as before and a backlit 1000 lp/in. grid. The QXI has been used on cylindrical implosion work at the Nova Laser Facility, and on direct-drive cylinder mix and indirect-drive high convergence implosion experiments at OMEGA. Its two-strip module has provided the capability to look at point backlighters, as part of technique development for experiments on the NIF. Its next use will be in March 2000 with its off axis viewer nose at Omega, providing a perpendicular view of Rayleigh--Taylor spike dissipation.

Evans, Scott C.; Archuleta, Tom N.; Oertel, John A.; Walsh, Peter J.

2001-01-01T23:59:59.000Z

336

High-resolution spectroscopic probes of collisions and half-collisions  

SciTech Connect (OSTI)

Research in this program explores the dynamics of gas phase collisions and photodissociation by high-resolution laser spectroscopy. Simultaneous state and velocity detection frequently permits a determination of scalar or vector correlations among products. The correlated product distributions are always more informative, and often easier to interpret than the uncorrelated product state distributions. The authors have recently built an apparatus to record transient absorption spectra with 50 nS time resolution and 20 MHz frequency resolution using a single frequency Ti:sapphire laser. The photodissociation of NCCN and C{sub 2}H{sub 5}SCN at 193 nm is discussed.

Hall, G.E. [Brookhaven National Laboratory, Upton, NY (United States)

1993-12-01T23:59:59.000Z

337

Imaging bolometer  

DOE Patents [OSTI]

Radiation-hard, steady-state imaging bolometer. A bolometer employing infrared (IR) imaging of a segmented-matrix absorber of plasma radiation in a cooled-pinhole camera geometry is described. The bolometer design parameters are determined by modeling the temperature of the foils from which the absorbing matrix is fabricated by using a two-dimensional time-dependent solution of the heat conduction equation. The resulting design will give a steady-state bolometry capability, with approximately 100 Hz time resolution, while simultaneously providing hundreds of channels of spatial information. No wiring harnesses will be required, as the temperature-rise data will be measured via an IR camera. The resulting spatial data may be used to tomographically investigate the profile of plasmas.

Wurden, Glen A. (Los Alamos, NM)

1999-01-01T23:59:59.000Z

338

Imaging bolometer  

DOE Patents [OSTI]

Radiation-hard, steady-state imaging bolometer is disclosed. A bolometer employing infrared (IR) imaging of a segmented-matrix absorber of plasma radiation in a cooled-pinhole camera geometry is described. The bolometer design parameters are determined by modeling the temperature of the foils from which the absorbing matrix is fabricated by using a two-dimensional time-dependent solution of the heat conduction equation. The resulting design will give a steady-state bolometry capability, with approximately 100 Hz time resolution, while simultaneously providing hundreds of channels of spatial information. No wiring harnesses will be required, as the temperature-rise data will be measured via an IR camera. The resulting spatial data may be used to tomographically investigate the profile of plasmas. 2 figs.

Wurden, G.A.

1999-01-19T23:59:59.000Z

339

Laser Cosmology  

E-Print Network [OSTI]

Recent years have seen tremendous progress in our understanding of the cosmos, which in turn points to even deeper questions to be further addressed. Concurrently the laser technology has undergone dramatic revolutions, providing exciting opportunity for science applications. History has shown that the symbiosis between direct observations and laboratory investigation is instrumental in the progress of astrophysics. We believe that this remains true in cosmology. Current frontier phenomena related to particle astrophysics and cosmology typically involve one or more of the following conditions: (1) extremely high energy events; (2) very high density, high temperature processes; (3) super strong field environments. Laboratory experiments using high intensity lasers can calibrate astrophysical observations, investigate underlying dynamics of astrophysical phenomena, and probe fundamental physics in extreme limits. In this article we give an overview of the exciting prospect of laser cosmology. In particular, we showcase its unique capability of investigating frontier cosmology issues such as cosmic accelerator and quantum gravity.

Pisin Chen

2014-02-24T23:59:59.000Z

340

Fundamenta Informaticae 133 1 A resolution calculus for first-order schemata  

E-Print Network [OSTI]

.Echenim@imag.fr Nicolas Peltier LIG/CNRS Nicolas.Peltier@imag.fr Abstract. We devise a resolution calculus that tests-2013-855 #12;2 V. Aravantinos, M. Echenim, N. Peltier / A resolution calculus for first-order schemata

Boyer, Edmond

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Laser barometer  

DOE Patents [OSTI]

A pressure measuring instrument that utilizes the change of the refractive index of a gas as a function of pressure and the coherent nature of a laser light to determine the barometric pressure within an environment. As the gas pressure in a closed environment varies, the index of refraction of the gas changes. The amount of change is a function of the gas pressure. By illuminating the gas with a laser light source, causing the wavelength of the light to change, pressure can be quantified by measuring the shift in fringes (alternating light and dark bands produced when coherent light is mixed) in an interferometer.

Abercrombie, Kevin R. (Westminster, CO); Shiels, David (Thornton, CO); Rash, Tim (Aurora, CO)

2001-02-06T23:59:59.000Z

342

Laser spectroscopy and dynamics of transient species  

SciTech Connect (OSTI)

The goal of this program is to study the vibrational and electronic spectra and excited state dynamics of a number of transient sulfur and oxygen species. A variety of supersonic jet techniques, as well as high resolution FT-IR and intracavity dye laser spectroscopy, have been applied to these studies.

Clouthier, D.J. [Univ. of Kentucky, Lexington (United States)

1993-12-01T23:59:59.000Z

343

Multigigahertz beam diagnostics for laser fusion  

SciTech Connect (OSTI)

A system to make ultra wideband measurements of fast laser pulses and their induced target interactions at a distance of approximately 38 m from the target location is discussed. The system has demonstrated an overall bandwidth of 3 GHz with projected unfolding to 4 GHz. This system allows high resolution temporal history diagnostics in a remote location providing high EMI and radiation immunity.

Smith, R.C.; Hodson, E.K.; Carlson, R.L.

1981-01-01T23:59:59.000Z

344

Applications of infrared laser spectroscopy to laser chemistry and laser development  

SciTech Connect (OSTI)

The impact on infrared molecular spectroscopy of high-resolution tunable laser sources and laser-controlled Fourier-transform spectrometers is discussed, with special reference to rovibrational spectra of spherical-top molecules such as CH/sub 4/, OsO/sub 4/, SiF/sub 4/, SF/sub 6/, and UF/sub 6/. The role of tunable laser spectroscopy in analyzing the CF/sub 4/ laser, resulting in the precise prediction of lasing frequencies between 605 and 655 cm/sup /minus/1/, is described. Studies of overtone and combination bands of SF/sub 6/ enable the vibrational anharmonicity to be determined, resulting in a more detailed description of the pump transitions involved in laser photochemistry, and of higher vibrational levels and pathways to excitation and dissociation. This permits more accurate calculations of vibrational state densities for spherical-top molecules. Implications for the photochemistry of species, such as SiF/sub 4/, SF/sub 6/, UF/sub 6/, and Ni(Co)/sub 4/, are discussed. 48 refs., 8 figs., 2 tabs.

McDowell, R.S.

1989-01-01T23:59:59.000Z

345

Lynx: A High-Resolution Synthetic Aperture Radar  

SciTech Connect (OSTI)

Lynx is a high resolution, synthetic aperture radar (SAR) that has been designed and built by Sandia National Laboratories in collaboration with General Atomics (GA). Although Lynx may be operated on a wide variety of manned and unmanned platforms, it is primarily intended to be fielded on unmanned aerial vehicles. In particular, it may be operated on the Predator, I-GNAT, or Prowler II platforms manufactured by GA Aeronautical Systems, Inc. The Lynx production weight is less than 120 lb. and has a slant range of 30 km (in 4 mm/hr rain). It has operator selectable resolution and is capable of 0.1 m resolution in spotlight mode and 0.3 m resolution in stripmap mode. In ground moving target indicator mode, the minimum detectable velocity is 6 knots with a minimum target cross-section of 10 dBsm. In coherent change detection mode, Lynx makes registered, complex image comparisons either of 0.1 m resolution (minimum) spotlight images or of 0.3 m resolution (minimum) strip images. The Lynx user interface features a view manager that allows it to pan and zoom like a video camera. Lynx was developed under corporate finding from GA and will be manufactured by GA for both military and commercial applications. The Lynx system architecture will be presented and some of its unique features will be described. Imagery at the finest resolutions in both spotlight and strip modes have been obtained and will also be presented.

Doerry, A.W.; Hensley, W.H.; Pace, F.; Stence, J.; Tsunoda, S.I.; Walker, B.C.; Woodring, M.

1999-03-08T23:59:59.000Z

346

Laser-induced fluorescence of fused silica irradiated by ArF excimer laser  

SciTech Connect (OSTI)

Laser-induced fluorescence (LIF) of high-purity fused silica irradiated by ArF excimer laser is studied experimentally. LIF bands of the fused silica centered at 281 nm, 478 nm, and 650 nm are observed simultaneously. Furthermore, the angular distribution of the three fluorescence peaks is examined. Microscopic image of the laser modified fused silica indicates that scattering of the generated fluorescence by laser-induced damage sites is the main reason for the angular distribution of LIF signals. Finally, the dependence of LIF signals intensities of the fused silica on laser power densities is presented. LIF signals show a squared power density dependence, which indicates that laser-induced defects are formed mainly via two-photon absorption processes.

Zhang Haibo [Shanghai Key Laboratory of All Solid-state Laser and Applied Techniques, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Science, Shanghai 201800 (China); Graduate University of Chinese Academy of Science, Beijing 100049 (China); Yuan Zhijun; Zhou Jun; Dong Jingxing; Wei Yunrong; Lou Qihong [Shanghai Key Laboratory of All Solid-state Laser and Applied Techniques, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Science, Shanghai 201800 (China)

2011-07-01T23:59:59.000Z

347

Applications of laser produced ion beams to nuclear analysis of materials  

SciTech Connect (OSTI)

Laser produced ion beams have unique characteristics which are ultra-short pulse, very low emittance, and variety of nuclear species. These characteristics could be used for analyzing various materials like low Z ion doped heavy metals or ceramics. Energies of laser produced ion beam extend from 0.1MeV to 100MeV. Therefore, various nuclear processes can be induced in the interactions of ion beams with samples. The ion beam driven nuclear analysis has been developed for many years by using various electrostatic accelerators. To explore the applicability of laser ion beam to the analysis of the Li ion battery, a proton beam with the diameter of {approx} 1.0 {mu}m at Takasaki Ion Acceleration for Advanced Radiation Application (TIARA), JAEA was used. For the analysis, the PIGE (Particle-Induced Gamma Ray Emission) is used. The proton beam scans over Li battery electrode samples to diagnose Li density in the LiNi{sub 0.85}Co{sub 0.15}O{sub 2} anode. As the results, PIGE images for Li area density distributions are obtained with the spatial resolution of better than 1.5{mu}m FWHM. By the Li PIGE images, the depth dependence of de-intercalation levels of Li in the anode is obtained. By the POP experiments at TIARA, it is clarified that laser produced ion beam is appropriate for the Li ion battery analysis. 41.85.Lc, 41.75.Jv, 42.62.cf.

Mima, K.; Azuma, H.; Fujita, K.; Yamazaki, A.; Okuda, C.; Ukyo, Y.; Kato, Y.; Arrabal, R. Gonzalez; Soldo, F.; Perlado, J. M.; Nishimura, H.; Nakai, S. [Graduate School for the Creation of New Photonics Industries, Shizuoka (Japan) and Institute de Fusion Nuclear, Universidad Politecnica de Madrid, Madrid (Spain) and Institute of Laser Engineering, Osaka University, Osaka (Japan); Toyota Central R and D Labs., Inc., Aichi (Japan); Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency (JAEA), Gunnma (Japan); Toyota Central R and D Labs., Inc., Aichi (Japan)

2012-07-11T23:59:59.000Z

348

Wavefront-sensor-based electron density measurements for laser-plasma accelerators  

E-Print Network [OSTI]

After imaging the plasma to a primary focus shortly afterfocus was 1 mm above the nozzle. The laser pulse excited a plasma

Plateau, Guillaume

2010-01-01T23:59:59.000Z

349

High Resolution Timing with Low Resolution Clocks A Microsecond Resolution Timer for Sun Workstations  

E-Print Network [OSTI]

High Resolution Timing with Low Resolution Clocks and A Microsecond Resolution Timer for Sun for Sun 3 and Sun 4 workstations1. One can measure average service times without a high resolution clock?" 1. Introduction - Who Needs a Microsecond Clock Beginning with its Sun 3 workstations, Sun

Melvin, Stephen

350

Soft x-ray backlighting of cryogenic implosions using a narrowband crystal imaging system (invited)  

SciTech Connect (OSTI)

A high-performance cryogenic DT inertial confinement fusion implosion experiment is an especially challenging backlighting configuration because of the high self-emission of the core at stagnation and the low opacity of the DT shell. High-energy petawatt lasers such as OMEGA EP promise significantly improved backlighting capabilities by generating high x-ray intensities and short emission times. A narrowband x-ray imager with an astigmatism-corrected bent quartz crystal for the Si He{sub ?} line at ?1.86 keV was developed to record backlit images of cryogenic direct-drive implosions. A time-gated recording system minimized the self-emission of the imploding target. A fast target-insertion system capable of moving the backlighter target ?7 cm in ?100 ms was developed to avoid interference with the cryogenic shroud system. With backlighter laser energies of ?1.25 kJ at a 10-ps pulse duration, the radiographic images show a high signal-to-background ratio of >100:1 and a spatial resolution of the order of 10 ?m. The backlit images can be used to assess the symmetry of the implosions close to stagnation and the mix of ablator material into the dense shell.

Stoeckl, C., E-mail: csto@lle.rochester.edu; Bedzyk, M.; Brent, G.; Epstein, R.; Fiksel, G.; Guy, D.; Goncharov, V. N.; Hu, S. X.; Ingraham, S.; Jacobs-Perkins, D. W.; Jungquist, R. K.; Marshall, F. J.; Mileham, C.; Nilson, P. M.; Sangster, T. C.; Shoup, M. J.; Theobald, W. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States)

2014-11-15T23:59:59.000Z

351

Femtosecond time-resolved photoemission electron microscopy for spatiotemporal imaging of photogenerated carrier dynamics in semiconductors  

SciTech Connect (OSTI)

We constructed an instrument for time-resolved photoemission electron microscopy (TR-PEEM) utilizing femtosecond (fs) laser pulses to visualize the dynamics of photogenerated electrons in semiconductors on ultrasmall and ultrafast scales. The spatial distribution of the excited electrons and their relaxation and/or recombination processes were imaged by the proposed TR-PEEM method with a spatial resolution about 100 nm and an ultrafast temporal resolution defined by the cross-correlation of the fs laser pulses (240 fs). A direct observation of the dynamical behavior of electrons on higher resistivity samples, such as semiconductors, by TR-PEEM has still been facing difficulties because of space and/or sample charging effects originating from the high photon flux of the ultrashort pulsed laser utilized for the photoemission process. Here, a regenerative amplified fs laser with a widely tunable repetition rate has been utilized, and with careful optimization of laser parameters, such as fluence and repetition rate, and consideration for carrier lifetimes, the electron dynamics in semiconductors were visualized. For demonstrating our newly developed TR-PEEM method, the photogenerated carrier lifetimes around a nanoscale defect on a GaAs surface were observed. The obtained lifetimes were on a sub-picosecond time scale, which is much shorter than the lifetimes of carriers observed in the non-defective surrounding regions. Our findings are consistent with the fact that structural defects induce mid-gap states in the forbidden band, and that the electrons captured in these states promptly relax into the ground state.

Fukumoto, Keiki, E-mail: fukumoto.k.ab@m.titech.ac.jp; Yamada, Yuki; Matsuki, Takashi; Koshihara, Shin-ya [Department of Materials Science, Tokyo Institute of Technology, Oookayama, Meguro-ku, Tokyo 152-8550 (Japan); Japan Science and Technology Agency JST-CREST, Honcho, Kawaguchi, Saitama 332-0012 (Japan); Onda, Ken [Interactive Research Center of Science, Tokyo Institute of Technology, Nagatsuta, Midori-ku, Yokohama 226-8502 (Japan); Japan Science and Technology Agency JST-PRESTO, Honcho, Kawaguchi, Saitama 332-0012 (Japan); Mukuta, Tatsuhiko; Tanaka, Sei-ichi [Department of Materials Science, Tokyo Institute of Technology, Oookayama, Meguro-ku, Tokyo 152-8550 (Japan)

2014-08-15T23:59:59.000Z

352

Particle detector spatial resolution  

DOE Patents [OSTI]

Method and apparatus for producing separated columns of scintillation layer material, for use in detection of X-rays and high energy charged particles with improved spatial resolution is disclosed. A pattern of ridges or projections is formed on one surface of a substrate layer or in a thin polyimide layer, and the scintillation layer is grown at controlled temperature and growth rate on the ridge-containing material. The scintillation material preferentially forms cylinders or columns, separated by gaps conforming to the pattern of ridges, and these columns direct most of the light produced in the scintillation layer along individual columns for subsequent detection in a photodiode layer. The gaps may be filled with a light-absorbing material to further enhance the spatial resolution of the particle detector. 12 figs.

Perez-Mendez, V.

1992-12-15T23:59:59.000Z

353

Particle detector spatial resolution  

DOE Patents [OSTI]

Method and apparatus for producing separated columns of scintillation layer material, for use in detection of X-rays and high energy charged particles with improved spatial resolution. A pattern of ridges or projections is formed on one surface of a substrate layer or in a thin polyimide layer, and the scintillation layer is grown at controlled temperature and growth rate on the ridge-containing material. The scintillation material preferentially forms cylinders or columns, separated by gaps conforming to the pattern of ridges, and these columns direct most of the light produced in the scintillation layer along individual columns for subsequent detection in a photodiode layer. The gaps may be filled with a light-absorbing material to further enhance the spatial resolution of the particle detector.

Perez-Mendez, Victor (Berkeley, CA)

1992-01-01T23:59:59.000Z

354

Free resolutions of algebras.  

E-Print Network [OSTI]

Given an algebra A, presented by generators and relations, i.e. as a quotient of a tensor algebra by an ideal, we construct a free algebra resolution of A, i.e. a differential graded algebra which is quasi-isomorphic to A and which is itself a tensor algebra. The construction rests combinatorially on the set of bracketings that arise naturally in the description of a free contractible differential graded algebra with given generators.

Joe Chuang; Alastair King

355

Laser Roadshow  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-SeriesFlickrinformationPostdocs space CombinedValuesRevolutionizingLaser

356

Nonlinear optical protection against frequency agile lasers  

SciTech Connect (OSTI)

An eye-protection or equipment-filter device for protection from laser energy is disclosed. The device may be in the form of a telescope, binoculars, goggles, constructed as part of equipment such as image intensifiers or range designators. Optical elements focus the waist of the beam within a nonlinear frequency-doubling crystal or nonlinear optical element or fiber. The nonlinear elements produce a harmonic outside the visible spectrum in the case of crystals, or absorb the laser energy in the case of nonlinear fibers. Embodiments include protectors for the human eye as well as filters for sensitive machinery such as TV cameras, FLIR systems or other imaging equipment.

McDowell, V.P.

1988-08-04T23:59:59.000Z

357

Predicting threshold and location of laser damage on optical surfaces  

DOE Patents [OSTI]

An apparatus useful in the prediction of the damage threshold of various optical devices, the location of weak spots on such devices and the location, identification, and elimination of optical surface impurities comprising, a focused and pulsed laser, an photo electric detector/imaging means, and a timer. The weak spots emit photoelectrons when subjected to laser intensities that are less than the intensity actually required to produce the damage. The weak spots may be eliminated by sustained exposure to the laser beam.

Siekhaus, Wigbert (Berkeley, CA)

1987-01-01T23:59:59.000Z

358

Laser/matter interactions by laser-launched plates and direct laser shocks  

SciTech Connect (OSTI)

Explosives, gas guns, laser-launched flyer plates, and direct laser-irradiation can be used to generate shocks and high-stress in materials. Each method has a unique diameter and thickness of shock that can be generated. In past years, small laboratory lasers have been used to launch flyer plates 2 - 200-pm thick to terminal velocities 0.1 to 5 k d s . Over the past few years we have been using our TRIDENT laser facility (1kJ in 0.2 to 2ps) to accelerate larger diameter (8 mm) and thicker (0.1 - 1.5 mm) flyer plates. These larger diameters and thicker one-dimensional plates more closely compliment traditional experimental methods such as gas guns. The 8-mm diameter and 1-mm thick flyer plates can impart shocks in metals for constitutive dynamic property measurements. The versatility of laser-driven plates permits spatial and temporal profiles of the flyer plate impact on sample targets. LASNEX models and parameters of the laser drive can be used to optimize optical coupling efficiency. The flyer plate launch, acceleration, terminal velocity, and, depending on the experiment, flyer plate impact on to target materials are recorded using point-interferometry (VISAR), and line-imaging interferometry. These high speed optical and laser experimental methods will be described along with ancillary methods, and material data. Constitutive properties of bulk materials, rate effects, and grain size and/or orientation have been studied for several metals including copper, beryllium, gold, and some alloys.

Paisley, Dennis L.; Swift, D. C. (Damian C.); Kopp, R. A. (Roger A.); Montgomery, D. S. (David S.); Johnson, R. P. (Randall P.); Munson, C. P. (Carter P.); Letzring, S. A. (Samuel A.); Niemczura, J. G. (Johnathan G.)

2003-01-01T23:59:59.000Z

359

High resolution time interval meter  

DOE Patents [OSTI]

Method and apparatus are provided for measuring the time interval between two events to a higher resolution than reliability available from conventional circuits and component. An internal clock pulse is provided at a frequency compatible with conventional component operating frequencies for reliable operation. Lumped constant delay circuits are provided for generating outputs at delay intervals corresponding to the desired high resolution. An initiation START pulse is input to generate first high resolution data. A termination STOP pulse is input to generate second high resolution data. Internal counters count at the low frequency internal clock pulse rate between the START and STOP pulses. The first and second high resolution data are logically combined to directly provide high resolution data to one counter and correct the count in the low resolution counter to obtain a high resolution time interval measurement.

Martin, A.D.

1986-05-09T23:59:59.000Z

360

Hypersonic gasdynamic laser system  

SciTech Connect (OSTI)

This patent describes a visible, or near to mid infra-red, hypersonic gas dynamic laser system. It comprises: a hypersonic vehicle for carrying the hypersonic gas dynamic laser system, and also providing high energy ram air for thermodynamic excitation and supply of the laser gas; a laser cavity defined within the hypersonic vehicle and having a laser cavity inlet for the laser cavity formed by an opening in the hypersonic vehicle, such that ram air directed through the laser cavity opening supports gas dynamic lasing operations at wavelengths less than 10.6{mu} meters in the laser cavity; and an optical train for collecting the laser radiation from the laser cavity and directing it as a substantially collimated laser beam to an output aperture defined by an opening in the hypersonic vehicle to allow the laser beam to be directed against a target.

Foreman, K.M.; Maciulaitis, A.

1990-05-22T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Imaging the evolution of an ultracold strontium Rydberg gas  

E-Print Network [OSTI]

Clouds of ultracold strontium 5s48s 1S0 or 5s47d 1D2 Rydberg atoms are created by two photon excitation of laser cooled 5s2 1S0 atoms. The spontaneous evolution of the cloud of low orbital angular momentum (low-l) Rydberg states towards an ultracold neutral plasma is observed by imaging resonant light scattered from core ions, a technique that provides both spatial and temporal resolution. Evolution is observed to be faster for the S-states, which display isotropic attractive interactions, than for the D-states, which exhibit anisotropic, principally repulsive interactions. Immersion of the atoms in a dilute ultracold neutral plasma speeds up the evolution and allows the number of Rydberg atoms initially created to be determined.

McQuillen, P; Strickler, T; Dunning, F B; Killian, T C

2012-01-01T23:59:59.000Z

362

Phase Retrieval Using Estimation Methods For Intensity Correlation Imaging  

E-Print Network [OSTI]

The angular resolution of an imaging system is sharply bounded by the diffraction limit, a fundamental property of electromagnetic radiation propagation. In order to increase resolution and see finer details of remote objects, the sizes...

Young, Brian T.

2010-10-12T23:59:59.000Z

363

Image texture analysis of elastograms  

E-Print Network [OSTI]

generated elastograms to obtain effective texture features. Four image analysis techniques, co-occurrence statistics, wavelet decomposition, fractal analysis and granulomeay are used to extract a number of features from each image. The inclusions...-RESOLUTION FRACTAL ANALYSIS . . . . . . E. GRANULOMETRIC FEATURES . . F. DATA NORMALIZATION . G. SEPARABILITY MEASURE 13 13 . . . . . 14 . . . . . 20 . . . . . 29 33 36 36 IV TEXTURE ANALYSIS OF SIMULATED ELASTOGRAMS. . . . . . . . . . . 38 A. SIMULATION...

Hussain, Fasahat

1999-01-01T23:59:59.000Z

364

Chirped pulse inverse free-electron laser vacuum accelerator  

DOE Patents [OSTI]

A chirped pulse inverse free-electron laser (IFEL) vacuum accelerator for high gradient laser acceleration in vacuum. By the use of an ultrashort (femtosecond), ultrahigh intensity chirped laser pulse both the IFEL interaction bandwidth and accelerating gradient are increased, thus yielding large gains in a compact system. In addition, the IFEL resonance condition can be maintained throughout the interaction region by using a chirped drive laser wave. In addition, diffraction can be alleviated by taking advantage of the laser optical bandwidth with negative dispersion focusing optics to produce a chromatic line focus. The combination of these features results in a compact, efficient vacuum laser accelerator which finds many applications including high energy physics, compact table-top laser accelerator for medical imaging and therapy, material science, and basic physics.

Hartemann, Frederic V. (Dublin, CA); Baldis, Hector A. (Pleasanton, CA); Landahl, Eric C. (Walnut Creek, CA)

2002-01-01T23:59:59.000Z

365

Laser programs highlights 1994  

SciTech Connect (OSTI)

This report provides highlights of the Lawrence Livermore National Laboratories` laser programs. Laser uses and technology assessment and utilization are provided.

NONE

1994-12-31T23:59:59.000Z

366

Laser Desorption Analysis | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Laser Desorption Analysis Laser Desorption Analysis EMSL offers a suite of instrumentation dedicated to understanding photoreactivity in the condensed phase, on surfaces, and at...

367

X-Ray Microscopy at BESSY: From Nano-Tomography to Fs-Imaging  

SciTech Connect (OSTI)

The BESSY X-ray microscopy group has developed a new full-field x-ray microscope with glass capillary condenser. It permits tomography and spectromicroscopy of cryogenic as well as heated samples. Correlative light and x-ray microscopy is supported by an incorporated high resolution light microscope. Spectromicroscopy with polarized x-rays from a helical undulator can be performed with E/{delta}E = 104. With the planned BESSY High Gain Harmonic Generation Free Electron Laser (HGHG-FEL) x-ray imaging with ultra-short pulses and an integral photon flux of about 1011 photons/pulse in an energy bandwidth of 0.1% will be possible. Single shot imaging with a full field Transmission X-ray Microscope (TXM) employing a beam shaper as a condenser will be feasible with 20 fs pulses.

Schneider, G.; Heim, S.; Rehbein, S.; Eichert, D. [BESSY GmbH, Albert Einstein Strasse 15, 12489 Berlin (Germany); Guttmann, P. [IRP, c/o BESSY m.b.H., Albert Einstein Strasse 15, 12489 Berlin (Germany); Niemann, B. [IRP, University of Goettingen, Friedrich-Hund-Platz 1, 37077 Goettingen (Germany)

2007-01-19T23:59:59.000Z

368

Lensless X-Ray Imaging in Reflection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Imaging in Reflection Print Wednesday, 26 October 2011 00:00 The advent of x-ray free-electron laser (XFEL) light sources has led to an outburst of research activities...

369

Signal and imaging sciences workshop proceedings  

SciTech Connect (OSTI)

Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.

Candy, J.V.

1997-11-01T23:59:59.000Z

370

Laser Safety Management Policy Statement ............................................................................................................1  

E-Print Network [OSTI]

Laser Safety Management Policy Statement...........................................................2 Laser Users.............................................................................................................2 Unit Laser Safety Officer (ULSO

Davidson, Fordyce A.

371

Broadband laser cooling of trapped atoms with ultrafast pulses  

E-Print Network [OSTI]

We demonstrate broadband laser cooling of atomic ions in an rf trap using ultrafast pulses from a modelocked laser. The temperature of a single ion is measured by observing the size of a time-averaged image of the ion in the known harmonic trap potential. While the lowest observed temperature was only about 1 K, this method efficiently cools very hot atoms and can sufficiently localize trapped atoms to produce near diffraction-limited atomic images.

B. B. Blinov; R. N. Kohn Jr.; M. J. Madsen; P. Maunz; D. L. Moehring; C. Monroe

2005-07-07T23:59:59.000Z

372

In Situ Laser Synthesis of Si Nanowires in the Dynamic TEM  

SciTech Connect (OSTI)

Nanowires (NWs) are a crucial component in today's nanoscale devices and are vital to the further development of nanotechnology. To achieve reliable growth of NWs and uniform electronic properties, the specific mechanisms that control the structural development of NWs and the correlation between NWs and their nucleation and growth processes must be examined. Because imaging is not possible in Chemical Vapor Deposition (CVD) chambers, in situ transmission electron microscope (TEM) based growth methods provide a method for characterizing NW evolution. In this paper, we describe a new method of in situ synthesis and imaging of NWs using laser-assisted growth inside a TEM. The vapor-liquid solid (VLS) growth mechanism (Figure 1), first described by Wagner and co-workers, is a widely accepted description of how many 1D nanostructures are formed. VLS and similar models have been applied to such methods as hybrid pulsed-laser ablation/chemical vapor deposition (PLA/CVD) and laser assisted NW growth at elevated temperatures, in which a pulsed laser ablates a target with gas flowing through the reaction chamber held at elevated temperature. These methods have successfully produced semiconductor and conducting oxide NWs with size control determined by the catalyst droplet diameter. The VLS description of NW growth is a widely accepted model, but the exact role of vapor species and its interaction with the catalyst particle is not fully understood. For example, NW growth has been observed to occur far below predicted eutectic temperatures, which suggests that alternative mechanisms such as solid-liquid-solid growth (SLS) may play a role. Many NW fabrication techniques preclude direct in situ characterization of the growth process. Because of this need for direct observation during growth, TEM-based NW growth methods have become increasingly popular. Though progress has been made in the study of the VLS mechanism of NW growth using in situ TEM, conventional in situ growth experiments are limited by the standard video frame rate ({approx}30 Hz). Because of this limitation, relationships between reactant incorporation and transport, catalyst-wire interface development, and wire growth texture remain somewhat unclear. Moreover, laser-assisted phenomena (PLA or PLA/CVD) cannot be studied with conventional in situ TEM, which is typically performed with environmental TEM techniques using resistive heating. A novel form of in situ TEM for the study of NW growth by laser-assisted techniques is described in this paper. Here we present an in situ method for PLA synthesis of 1D nanostructures using the dynamic transmission electron microscope (DTEM)[18,19] that will permit the details of laser-assisted NW synthesis to be elucidated. The DTEM, schematically shown in Figure 2, consists of a TEM column (JEOL 2000FX) to which a pulsed Nd:YAG laser, labeled 'hydrodrive laser' in Fig. 2, is added. This laser is incident directly on the sample and can be operated at 1064, 532 or 355nm. The direct delivery of energy initiates a phase change or reaction that is investigated in situ during the experiment. Thus, the microscope can be used to fabricate NWs while simultaneously characterizing the reaction products created by each laser pulse. A second pulsed laser (15-ns-duration frequency-quintupled Nd:YLF) added to the column (labeled 'cathode laser' in figure 2) enables operation in both a pulsed photoemission and conventional thermionic continuous-wave (CW) electron beam imaging modes.[19] The pulsed mode's nanosecond-scale imaging capability greatly exceeds the {approx}30 Hz time resolution of conventional in situ TEM and can potentially provide a detailed understanding of NW growth. Time-resolved imaging experiments aimed at capturing the intermediate states at nanosecond time scales in PLA NW growth are underway and will be addressed in a future publication. In this paper, we present results obtained using in situ imaging in conventional CW imaging mode, but taking advantage of the DTEM's in situ laser drive capability. Specifically, we will present

Taheri, M; Reed, B; LaGrange, T; Browning, N

2007-12-05T23:59:59.000Z

373

Laser Faraday  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: VegetationEquipment Surfaces and Interfaces Sample6, 2011 CERN 73-11LargeLaser Enables InexpensiveFaraday

374

Fiber Lasers  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert Southwest Region service area. TheEPSCI HomeTours, Programs and EventsFiber Lasers NIF

375

Comparison of Long-Wave Infrared Imaging and Visible/Near-Infrared Imaging of Vegetation for  

E-Print Network [OSTI]

Comparison of Long-Wave Infrared Imaging and Visible/Near-Infrared Imaging of Vegetation using spectral imaging. This has been accom- plished with both visible/near-infrared (Vis/NIR) sunlight-path laser absorption measurements [14]­[16], in-situ visible and near-infrared (Vis/NIR) spectral

Lawrence, Rick L.

376

Optic for an endoscope/borescope having high resolution and narrow field of view  

DOE Patents [OSTI]

An optic having optimized high spatial resolution, minimal nonlinear magnification distortion while at the same time having a limited chromatic focal shift or chromatic aberrations. The optic located at the distal end of an endoscopic inspection tool permits a high resolution, narrow field of view image for medical diagnostic applications, compared to conventional optics for endoscopic instruments which provide a wide field of view, low resolution image. The image coverage is over a narrow (<20 degrees) field of view with very low optical distortion (<5% pin cushion or barrel distortion. The optic is also optimized for best color correction as well as to aid medical diagnostics.

Stone, Gary F.; Trebes, James E.

2003-10-28T23:59:59.000Z

377

Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee—image quality and diagnostic performance  

E-Print Network [OSTI]

SB (2007) High-resolution 3D cartilage imaging with IDEALMa Thomas M. Link Isotropic 3D fast spin-echo imaging versusintermediate-weighted (IM-w) 3D fast spin-echo (FSE) se-

2009-01-01T23:59:59.000Z

378

Environmental Conflict Resolution | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Environmental Conflict Resolution Environmental Conflict Resolution ENVIRONMENTAL CONFLICT RESOLUTION In September 2012, the Council on Environmental Quality (CEQ) and the Office...

379

Harmonic resolution as a holographic quantum number  

E-Print Network [OSTI]

LBNL- 57239 Harmonic resolution as a holographic quantumhep-th/0310223 UCB-PTH-03/26 Harmonic resolution as aquantum number, the harmonic resolution K. The Bekenstein

Bousso, Raphael

2009-01-01T23:59:59.000Z

380

Imaging the Coso geothermal area crustal structure with an array...  

Open Energy Info (EERE)

resolution images of the crust and mantle than have been previously obtainable. The Earth is appearing to be more heterogeneous than was thought when only rougher scale...

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

New imaging technique provides improved insight into controlling...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Download Select and View High Resolution Images to Download Learn More Fusion energy Fusion reactor design ITER Nuclear energy Plasma diagnostics Plasma physics Tokamaks...

382

Algorithms for enhanced spatiotemporal imaging of human brain function  

E-Print Network [OSTI]

Studies of human brain function require technologies to non-invasively image neuronal dynamics with high spatiotemporal resolution. The electroencephalogram (EEG) and magnetoencephalogram (MEG) measure neuronal activity ...

Krishnaswamy, Pavitra

2014-01-01T23:59:59.000Z

383

Fourier plane image amplifier  

DOE Patents [OSTI]

A solid state laser is frequency tripled to 0.3 .mu.m. A small portion of the laser is split off and generates a Stokes seed in a low power oscillator. The low power output passes through a mask with the appropriate hole pattern. Meanwhile, the bulk of the laser output is focused into a larger stimulated Brillouin scattering (SBS) amplifier. The low power beam is directed through the same cell in the opposite direction. The majority of the amplification takes place at the focus which is the fourier transform plane of the mask image. The small holes occupy large area at the focus and thus are preferentially amplified. The amplified output is now imaged onto the multichip module where the holes are drilled. Because of the fourier plane amplifier, only .about.1/10th the power of a competitive system is needed. This concept allows less expensive masks to be used in the process and requires much less laser power.

Hackel, Lloyd A. (Livermore, CA); Hermann, Mark R. (San Ramon, CA); Dane, C. Brent (Livermore, CA); Tiszauer, Detlev H. (Tracy, CA)

1995-01-01T23:59:59.000Z

384

Narrow gap laser welding  

DOE Patents [OSTI]

A laser welding process including: (a) using optical ray tracing to make a model of a laser beam and the geometry of a joint to be welded; (b) adjusting variables in the model to choose variables for use in making a laser weld; and (c) laser welding the joint to be welded using the chosen variables.

Milewski, John O. (Santa Fe, NM); Sklar, Edward (Santa Fe, NM)

1998-01-01T23:59:59.000Z

385

Narrow gap laser welding  

DOE Patents [OSTI]

A laser welding process including: (a) using optical ray tracing to make a model of a laser beam and the geometry of a joint to be welded; (b) adjusting variables in the model to choose variables for use in making a laser weld; and (c) laser welding the joint to be welded using the chosen variables. 34 figs.

Milewski, J.O.; Sklar, E.

1998-06-02T23:59:59.000Z

386

Short wavelength laser  

DOE Patents [OSTI]

A short wavelength laser is provided that is driven by conventional-laser pulses. A multiplicity of panels, mounted on substrates, are supported in two separated and alternately staggered facing and parallel arrays disposed along an approximately linear path. When the panels are illuminated by the conventional-laser pulses, single pass EUV or soft x-ray laser pulses are produced.

Hagelstein, P.L.

1984-06-25T23:59:59.000Z

387

Longitudinal discharge laser baffles  

DOE Patents [OSTI]

The IR baffles placed between the window and the electrode of a longitudinal discharge laser improve laser performance by intercepting off-axis IR radiation from the laser and in doing so reduce window heating and subsequent optical distortion of the laser beam. 1 fig.

Warner, B.E.; Ault, E.R.

1994-06-07T23:59:59.000Z

388

ablation laser spectrometer  

E-Print Network [OSTI]

ablation laser mass spectrometer molecular beam REMPI laser NREL has designed and developed a combined laser ablation/ pulsed sample introduction/mass spectrometry platform that integrates pyrolysis and/or laser ablation with resonance- enhanced multiphoton ionization (REMPI) time-of-flight mass

389

Apparatus and method for laser velocity interferometry  

DOE Patents [OSTI]

An apparatus and method for laser velocity interferometry employing a fixed interferometer cavity and delay element. The invention permits rapid construction of interferometers that may be operated by those non-skilled in the art, that have high image quality with no drift or loss of contrast, and that have long-term stability even without shock isolation of the cavity.

Stanton, Philip L. (Bernalillo County, NM); Sweatt, William C. (Albuquerque, NM); Crump, Jr., O. B. (Albuquerque, NM); Bonzon, Lloyd L. (Albuquerque, NM)

1993-09-14T23:59:59.000Z

390

High resolution non-contact thermal characterization of semiconductor devices  

E-Print Network [OSTI]

imaging can have spatial resolution better than the diffraction limit of an infrared camera and can work infrared microscopes. Also, since the thermoreflectance technique does not rely upon the emitted black body measured the heating on a 35x35 micron MOS transistor, and Mansanares5 who measured temperature

391

Identification marking by means of laser peening  

DOE Patents [OSTI]

The invention is a method and apparatus for marking components by inducing a shock wave on the surface that results in an indented (strained) layer and a residual compressive stress in the surface layer. One embodiment of the laser peenmarking system rapidly imprints, with single laser pulses, a complete identification code or three-dimensional pattern and leaves the surface in a state of deep residual compressive stress. A state of compressive stress in parts made of metal or other materials is highly desirable to make them resistant to fatigue failure and stress corrosion cracking. This process employs a laser peening system and beam spatial modulation hardware or imaging technology that can be setup to impress full three dimensional patterns into metal surfaces at the pulse rate of the laser, a rate that is at least an order of magnitude faster than competing marking technologies.

Hackel, Lloyd A. (Livermore, CA); Dane, C. Brent (Livermore, CA); Harris, Fritz (Rocklin, CA)

2002-01-01T23:59:59.000Z

392

Contour forming of metals by laser peening  

DOE Patents [OSTI]

A method and apparatus are provided for forming shapes and contours in metal sections by generating laser induced compressive stress on the surface of the metal workpiece. The laser process can generate deep compressive stresses to shape even thick components without inducing unwanted tensile stress at the metal surface. The precision of the laser-induced stress enables exact prediction and subsequent contouring of parts. A light beam of 10 to 100 J/pulse is imaged to create an energy fluence of 60 to 200 J/cm.sup.2 on an absorptive layer applied over a metal surface. A tamping layer of water is flowed over the absorptive layer. The absorption of laser light causes a plasma to form and consequently creates a shock wave that induces a deep residual compressive stress into the metal. The metal responds to this residual stress by bending.

Hackel, Lloyd (Livermore, CA); Harris, Fritz (Rocklin, CA)

2002-01-01T23:59:59.000Z

393

Stress Evaluation and Model Validation Using Laser Ultrasonics  

SciTech Connect (OSTI)

Rayleigh surface waves can be used to evaluate surface stresses and through-thickness stress gradients based on acoustoelasticity. Laser based ultrasonic techniques, which generate and detect surface waves, have the advantages of good spatial resolution and remote operation. The techniques have many potential applications. This is the final report of a LDRD project that is the first to exploit the benefits of laser ultrasonics for stress and stress gradient evaluation.

Dike, Jay J.; Lu, Wei-yang; Peng, Lawrence W.; Wang, James C. F.

1999-02-01T23:59:59.000Z

394

Laser Processing of Metals and Polymers  

SciTech Connect (OSTI)

A laser offers a unique set of opportunities for precise delivery of high quality coherent energy. This energy can be tailored to alter the properties of material allowing a very flexible adjustment of the interaction that can lead to melting, vaporization, or just surface modification. Nowadays laser systems can be found in nearly all branches of research and industry for numerous applications. Sufficient evidence exists in the literature to suggest that further advancements in the field of laser material processing will rely significantly on the development of new process schemes. As a result they can be applied in various applications starting from fundamental research on systems, materials and processes performed on a scientific and technical basis for the industrial needs. The interaction of intense laser radiation with solid surfaces has extensively been studied for many years, in part, for development of possible applications. In this thesis, I present several applications of laser processing of metals and polymers including polishing niobium surface, producing a superconducting phase niobium nitride and depositing thin films of niobium nitride and organic material (cyclic olefin copolymer). The treated materials were examined by scanning electron microscopy (SEM), electron probe microanalysis (EPMA), atomic force microscopy (AFM), high resolution optical microscopy, surface profilometry, Fourier transform infrared spectroscopy (FTIR) and x-ray diffraction (XRD). Power spectral density (PSD) spectra computed from AFM data gives further insight into the effect of laser melting on the topography of the treated niobium.

Senthilraja Singaravelu

2012-05-31T23:59:59.000Z

395

Ballistic Imaging of High-Pressure Fuel Sprays using Incoherent, Ultra- short Pulsed Illumination with an Ultrafast OKE-based Time Gating  

E-Print Network [OSTI]

We present an optical Kerr effect based time-gate with the collinear incidence of the pump and probe beams at the Kerr medium, liquid carbon disulfide, for ballistic imaging of the high-pressure fuel sprays. The probe pulse used to illuminate the object under study is extracted from the supercontinuum generated by tightly focusing intense femtosecond laser pulses inside water, thereby destroying their coherence. The optical imaging spatial resolution and gate timings are investigated and compared with a similar setup without supercontinuum generation, where the probe is still coherent. And finally, a few ballistic images of the fuel sprays using coherent and incoherent illumination with the proposed time-gate are presented and compared qualitatively.

Purwar, Harsh; Rozé, Claude; Blaisot, Jean-Bernard

2015-01-01T23:59:59.000Z

396

Low power cw-laser signatures on human skin  

SciTech Connect (OSTI)

Impact of cw laser radiation on autofluorescence features of human skin is studied. Two methods of autofluorescence detection are applied: the spectral method with the use of a fibreoptic probe and spectrometer for determining the autofluorescence recovery kinetics at a fixed skin area of {approx}12 mm{sup 2}, and the multispectral visualisation method with the use of a multispectral imaging camera for visualising long-term autofluorescence changes in a skin area of {approx}4 cm{sup 2}. The autofluorescence recovery kinetics after preliminary laser irradiation is determined. Skin autofluorescence images with visible long-term changes - 'signatures' of low power laser treatment are acquired. (application of lasers and laser-optical methods in life sciences)

Lihachev, A; Lesinsh, J; Jakovels, D; Spigulis, J [Institute of Atomic Physics and Spectroscopy, University of Latvia, Riga (Latvia)

2011-01-24T23:59:59.000Z

397

Ames Lab 101: Real-Time 3D Imaging  

ScienceCinema (OSTI)

Ames Laboratory scientist Song Zhang explains his real-time 3-D imaging technology. The technique can be used to create high-resolution, real-time, precise, 3-D images for use in healthcare, security, and entertainment applications.

Zhang, Song

2012-08-29T23:59:59.000Z

398

Remote imaging of concealed objects  

SciTech Connect (OSTI)

Optical detection of objects hidden behind opaque screening layers is a challenging problem. We demonstrate an optically detected echographic-like method that combines collimated acoustic and laser beams. The acoustic waves cross the screening layers and their back-reflection from the hidden objects is detected through the analysis of a dynamic laser speckle pattern created at the outer surface of the screening layer. Real-time remote detection of moving targets 15 meters away, with a few mm resolutions is demonstrated using a very sensitive camera detection scheme.

Lev, Aner, E-mail: lev@soreq.gov.il; Sfez, Bruno, E-mail: lev@soreq.gov.il [Soreq NRC, Yavne, 81800 (Israel)

2014-05-27T23:59:59.000Z

399

1 Resolution 1.1 Resolution in propositional logic  

E-Print Network [OSTI]

is satisfiable if there exists a valuation such that ^() = T for all F; otherwise we say that F consequence of F if all valuations satisfying F also satisfy . Observation 3. A formula is a logical the soundness theorem for resolution method (If there exists a resolution proof of inconsistency of a set

Charatonik, Witold

400

Calculation of the spatial resolution in two-photon absorption spectroscopy applied to plasma diagnosis  

SciTech Connect (OSTI)

We report a detailed characterization of the spatial resolution provided by two-photon absorption spectroscopy suited for plasma diagnosis via the 1S-2S transition of atomic hydrogen for optogalvanic detection and laser induced fluorescence (LIF). A precise knowledge of the spatial resolution is crucial for a correct interpretation of measurements, if the plasma parameters to be analysed undergo strong spatial variations. The present study is based on a novel approach which provides a reliable and realistic determination of the spatial resolution. Measured irradiance distribution of laser beam waists in the overlap volume, provided by a high resolution UV camera, are employed to resolve coupled rate equations accounting for two-photon excitation, fluorescence decay and ionization. The resulting three-dimensional yield distributions reveal in detail the spatial resolution for optogalvanic and LIF detection and related saturation due to depletion. Two-photon absorption profiles broader than the Fourier transform-limited laser bandwidth are also incorporated in the calculations. The approach allows an accurate analysis of the spatial resolution present in recent and future measurements.

Garcia-Lechuga, M. [Departamento de Física Teórica, Atómica y Óptica, Universidad de Valladolid, 47011-Valladolid (Spain); Laser Processing Group, Instituto de Óptica “Daza de Valdés,” CSIC, 28006-Madrid (Spain); Fuentes, L. M. [Departamento de Física Aplicada, Universidad de Valladolid, 47011-Valladolid (Spain); Grützmacher, K.; Pérez, C., E-mail: concha@opt.uva.es; Rosa, M. I. de la [Departamento de Física Teórica, Atómica y Óptica, Universidad de Valladolid, 47011-Valladolid (Spain)

2014-10-07T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Imaging, Characterizing, and Modeling of Fracture Networks and Fluid Flow in EGS Reservoirs  

Broader source: Energy.gov [DOE]

Project objectives: Improve image resolution for microseismicimaging and time-lapse active seismic imaging; Enhance the prediction of fluid flow and temperature distributions and stress changes by coupling fracture flow simulations with reservoir flow simulations; and integrating imaging into modeling.

402

Laser ablated hard coating for microtools  

DOE Patents [OSTI]

Wear-resistant coatings composed of laser ablated hard carbon films, are deposited by pulsed laser ablation using visible light, on instruments such as microscope tips and micro-surgical tools. Hard carbon, known as diamond-like carbon (DLC), films produced by pulsed laser ablation using visible light enhances the abrasion resistance, wear characteristics, and lifetimes of small tools or instruments, such as small, sharp silicon tips used in atomic probe microscopy without significantly affecting the sharpness or size of these devices. For example, a 10-20 nm layer of diamond-like carbon on a standard silicon atomic force microscope (AFM) tip, enables the useful operating life of the tip to be increased by at least twofold. Moreover, the low inherent friction coefficient of the DLC coating leads to higher resolution for AFM tips operating in the contact mode.

McLean, II, William (Oakland, CA); Balooch, Mehdi (Berkeley, CA); Siekhaus, Wigbert J. (Berkeley, CA)

1998-05-05T23:59:59.000Z

403

Laser ablated hard coating for microtools  

DOE Patents [OSTI]

Wear-resistant coatings composed of laser ablated hard carbon films, are deposited by pulsed laser ablation using visible light, on instruments such as microscope tips and micro-surgical tools. Hard carbon, known as diamond-like carbon (DLC), films produced by pulsed laser ablation using visible light enhances the abrasion resistance, wear characteristics, and lifetimes of small tools or instruments, such as small, sharp silicon tips used in atomic probe microscopy without significantly affecting the sharpness or size of these devices. For example, a 10--20 nm layer of diamond-like carbon on a standard silicon atomic force microscope (AFM) tip, enables the useful operating life of the tip to be increased by at least twofold. Moreover, the low inherent friction coefficient of the DLC coating leads to higher resolution for AFM tips operating in the contact mode. 12 figs.

McLean, W. II; Balooch, M.; Siekhaus, W.J.

1998-05-05T23:59:59.000Z

404

The Extragalactic Lens VLBI Imaging Survey (ELVIS) : investigating galaxy cores and black holes with gravitational lens central images  

E-Print Network [OSTI]

This thesis describes the Extragalactic Lens VLBI Imaging Survey (ELVIS), a search for central images in gravitational lenses. We present the first four ELVIS targets, for which we have radio VLBI observations with resolutions ...

Boyce, Edward R

2006-01-01T23:59:59.000Z

405

E-Print Network 3.0 - angstrom resolution insights Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

in high resolution... on the techniques he has developed to image the sun, both in white light and in the sub-angstrom hydrogen alpha Source: Dawson, John F.- Department of...

406

Super-resolution wide-field optical microscopy by use of Evanescent standing waves  

E-Print Network [OSTI]

The development of high resolution, high speed imaging techniques allows the study of dynamical processes in biological systems. Optical fluorescence microscopy is an essential tool for investigations in many disciplines ...

Chung, Euiheon

2007-01-01T23:59:59.000Z

407

Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution  

E-Print Network [OSTI]

Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution Eric C. Wong,* Wen the ASL SNR per image. We refer to this modified technique as turbo ASL. THEORY In pulsed ASL techniques

Sereno, Martin

408

Towards the clinical application of laser-induced breakdown spectroscopy for rapid pathogen diagnosis Qassem Mohaidat  

E-Print Network [OSTI]

and Microbiology) Asst. Prof. Choong-Min Kang (WSU Dept. of Biological Sciences) Asst. Prof. Hossein Salimnia (WSU of Pathogenic Bacteria: A Spectroscopy Experiment at the Crossroads of Atomic Physics and Microbiology," S- resolution spectrometer, laser power supply, computer, and battery Hand-held probe contains laser, joystick

Rehse, Steven J.

409

Strain compensation in boron-indium coimplanted laser thermal processed silicon  

E-Print Network [OSTI]

Strain compensation in boron-indium coimplanted laser thermal processed silicon Mark H. Clarka Strain in B-implanted laser thermal processed LTP silicon is reduced by coimplantation of In. Strain in the codoped layer is calculated using lattice constants measured by high-resolution x-ray diffraction

Florida, University of

410

Cryogenic scanning Hall-probe microscope with centimeter scan range and submicron resolution  

E-Print Network [OSTI]

with 200 nm positioning resolution by coupling stepper motors to high-resolution drivers and reducing gears in coated conductors--high-Tc superconducting tapes--is demonstrated via model systems. We image an entire also use motor-driven microme- ters but couple them to improved electronics and reducing gears

Moler, Kathryn A.

411

Dynamic imaging with electron microscopy  

SciTech Connect (OSTI)

Livermore researchers have perfected an electron microscope to study fast-evolving material processes and chemical reactions. By applying engineering, microscopy, and laser expertise to the decades-old technology of electron microscopy, the dynamic transmission electron microscope (DTEM) team has developed a technique that can capture images of phenomena that are both very small and very fast. DTEM uses a precisely timed laser pulse to achieve a short but intense electron beam for imaging. When synchronized with a dynamic event in the microscope's field of view, DTEM allows scientists to record and measure material changes in action. A new movie-mode capability, which earned a 2013 R&D 100 Award from R&D Magazine, uses up to nine laser pulses to sequentially capture fast, irreversible, even one-of-a-kind material changes at the nanometer scale. DTEM projects are advancing basic and applied materials research, including such areas as nanostructure growth, phase transformations, and chemical reactions.

Campbell, Geoffrey; McKeown, Joe; Santala, Melissa

2014-02-20T23:59:59.000Z

412

Dynamic imaging with electron microscopy  

ScienceCinema (OSTI)

Livermore researchers have perfected an electron microscope to study fast-evolving material processes and chemical reactions. By applying engineering, microscopy, and laser expertise to the decades-old technology of electron microscopy, the dynamic transmission electron microscope (DTEM) team has developed a technique that can capture images of phenomena that are both very small and very fast. DTEM uses a precisely timed laser pulse to achieve a short but intense electron beam for imaging. When synchronized with a dynamic event in the microscope's field of view, DTEM allows scientists to record and measure material changes in action. A new movie-mode capability, which earned a 2013 R&D 100 Award from R&D Magazine, uses up to nine laser pulses to sequentially capture fast, irreversible, even one-of-a-kind material changes at the nanometer scale. DTEM projects are advancing basic and applied materials research, including such areas as nanostructure growth, phase transformations, and chemical reactions.

Campbell, Geoffrey; McKeown, Joe; Santala, Melissa

2014-05-30T23:59:59.000Z

413

Enhanced High Resolution RBS System  

SciTech Connect (OSTI)

Improvements in full spectrum resolution with the second NEC high resolution RBS system are summarized. Results for 50 A ring TiN/HfO films on Si yielding energy resolution on the order of 1 keV are also presented. Detector enhancements include improved pulse processing electronics, upgraded shielding for the MCP/RAE detector, and reduced noise generated from pumping. Energy resolution measurements on spectra front edge coupled with calculations using 0.4mStr solid angle show that beam energy spread at 400 KeV from the Pelletron registered accelerator is less than 100 eV. To improve user throughput, magnet control has been added to the automatic data collection. Depth profiles derived from experimental data are discussed. For the thin films profiled, depth resolutions were on the Angstrom level with the non-linear energy/channel conversions ranging from 100 to 200 eV.

Pollock, Thomas J.; Hass, James A.; Klody, George M. [National Electrostatics Corp., Middleton, Wisconsin, U. S. A. 53562-0310 (United States)

2011-06-01T23:59:59.000Z

414

Apparatus and method for laser beam diagnosis  

DOE Patents [OSTI]

An apparatus and method is disclosed for accurate, real time monitoring of the wavefront curvature of a coherent laser beam. Knowing the curvature, it can be quickly determined whether the laser beam is collimated, or focusing (converging), or de-focusing (diverging). The apparatus includes a lateral interferometer for forming an interference pattern of the laser beam to be diagnosed. The interference pattern is imaged to a spatial light modulator (SLM), whose output is a coherent laser beam having an image of the interference pattern impressed on it. The SLM output is focused to obtain the far-field diffraction pattern. A video camera, such as CCD, monitors the far-field diffraction pattern, and provides an electrical output indicative of the shape of the far-field pattern. Specifically, the far-field pattern comprises a central lobe and side lobes, whose relative positions are indicative of the radius of curvature of the beam. The video camera's electrical output may be provided to a computer which analyzes the data to determine the wavefront curvature of the laser beam.

Salmon, Jr., Joseph T. (Livermore, CA)

1991-01-01T23:59:59.000Z

415

Apparatus and method for laser beam diagnosis  

DOE Patents [OSTI]

An apparatus and method are disclosed for accurate, real time monitoring of the wavefront curvature of a coherent laser beam. Knowing the curvature, it can be quickly determined whether the laser beam is collimated, or focusing (converging), or de-focusing (diverging). The apparatus includes a lateral interferometer for forming an interference pattern of the laser beam to be diagnosed. The interference pattern is imaged to a spatial light modulator (SLM), whose output is a coherent laser beam having an image of the interference pattern impressed on it. The SLM output is focused to obtain the far-field diffraction pattern. A video camera, such as CCD, monitors the far-field diffraction pattern, and provides an electrical output indicative of the shape of the far-field pattern. Specifically, the far-field pattern comprises a central lobe and side lobes, whose relative positions are indicative of the radius of curvature of the beam. The video camera's electrical output may be provided to a computer which analyzes the data to determine the wavefront curvature of the laser beam. 11 figures.

Salmon, J.T. Jr.

1991-08-27T23:59:59.000Z

416

Multimodality Imaging Atlas of Coronary Atherosclerosis  

E-Print Network [OSTI]

NEW HIGH-RESOLUTION IMAGING TECHNOLOGIES HAVE ENHANCED OUR UNDERSTANDING OF THE CORONARY atherosclerotic disease process, and this atlas provides a multimodality pictorial review of the development of histologically verified ...

Donnelly, Patrick

417

A ber-optic based calibration system for the High Resolution Fly's Eye  

E-Print Network [OSTI]

A ber-optic based calibration system for the High Resolution Fly's Eye cosmic ray observatory J, 800 Yale Blvd NE, Albuquerque, NM 87131-1156 Abstract This article describes the ber-optic based: Highest energy cosmic rays Fly's Eye Experiment HiRes YAG Laser Fiber-optics PMT PACS: 95.45.+i 95.85.Ls

418

Apparatus for precision micromachining with lasers  

DOE Patents [OSTI]

A new material processing apparatus using a short-pulsed, high-repetition-rate visible laser for precision micromachining utilizes a near diffraction limited laser, a high-speed precision two-axis tilt-mirror for steering the laser beam, an optical system for either focusing or imaging the laser beam on the part, and a part holder that may consist of a cover plate and a back plate. The system is generally useful for precision drilling, cutting, milling and polishing of metals and ceramics, and has broad application in manufacturing precision components. Precision machining has been demonstrated through percussion drilling and trepanning using this system. With a 30 W copper vapor laser running at multi-kHz pulse repetition frequency, straight parallel holes with size varying from 500 microns to less than 25 microns and with aspect ratios up to 1:40 have been consistently drilled with good surface finish on a variety of metals. Micromilling and microdrilling on ceramics using a 250 W copper vapor laser have also been demonstrated with good results. Materialographic sections of machined parts show little (submicron scale) recast layer and heat affected zone. 1 fig.

Chang, J.J.; Dragon, E.P.; Warner, B.E.

1998-04-28T23:59:59.000Z

419

Apparatus for precision micromachining with lasers  

DOE Patents [OSTI]

A new material processing apparatus using a short-pulsed, high-repetition-rate visible laser for precision micromachining utilizes a near diffraction limited laser, a high-speed precision two-axis tilt-mirror for steering the laser beam, an optical system for either focusing or imaging the laser beam on the part, and a part holder that may consist of a cover plate and a back plate. The system is generally useful for precision drilling, cutting, milling and polishing of metals and ceramics, and has broad application in manufacturing precision components. Precision machining has been demonstrated through percussion drilling and trepanning using this system. With a 30 W copper vapor laser running at multi-kHz pulse repetition frequency, straight parallel holes with size varying from 500 microns to less than 25 microns and with aspect ratios up to 1:40 have been consistently drilled with good surface finish on a variety of metals. Micromilling and microdrilling on ceramics using a 250 W copper vapor laser have also been demonstrated with good results. Materialogroaphic sections of machined parts show little (submicron scale) recast layer and heat affected zone.

Chang, Jim J. (Dublin, CA); Dragon, Ernest P. (Danville, CA); Warner, Bruce E. (Pleasanton, CA)

1998-01-01T23:59:59.000Z

420

Laser-assisted electrochemistry  

SciTech Connect (OSTI)

The effect of laser irradiation on electrodeposition processes has been investigated. These studies demonstrated that the addition of laser irradiation to an electroplating process can dramatically enhance plating rates and current efficiencies, as well as improve the morphology of the resultant electrodeposit. During the course of these investigations, the mechanism for the laser enhancement of electrodeposition processes was determined. Experimental evidence was obtained to show that laser irradiation of the substrate results in increased metal ion concentrations at the surface of the electrode due to a laser-induced Soret effect. The laser-induced Soret effect has important implications for laser-assisted electrochemical processing. The increase in the surface concentration of ions allows efficient electrodeposition from dilute solutions. As such, laser- assisted electrodeposition may develop into an environmentally conscious manufacturing process by reducing waste and limiting worker exposure to toxic chemicals.

Glenn, D.F.

1995-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Along the Laser Beampath  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

9 20 | Next | Last Back to Index NIF Laser Bay Seen from above, each of NIF's two identical laser bays has two clusters of 48 beamlines, one on either side of the utility spine...

422

Laser particle sorter  

DOE Patents [OSTI]

Method and apparatus are provided for sorting particles, such as biological particles. A first laser is used to define an optical path having an intensity gradient which is effective to propel the particles along the path but which is sufficiently weak that the particles are not trapped in an axial direction. A probe laser beam is provided for interrogating the particles to identify predetermined phenotypical characteristics of the particles. A second laser beam is provided to intersect the driving first laser beam, wherein the second laser beam is activated by an output signal indicative of a predetermined characteristic. The second laser beam is switchable between a first intensity and a second intensity, where the first intensity is effective to displace selected particles from the driving laser beam and the second intensity is effective to propel selected particles along the deflection laser beam. The selected particles may then be propelled by the deflection beam to a location effective for further analysis. 2 figs.

Martin, J.C.; Buican, T.N.

1987-11-30T23:59:59.000Z

423

Along the Laser Beampath  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

has been installed in the preamplifier modules (PAMs) at the front end of the NIF laser system. The spatial shapers can obscure the laser light at programmed locations within...

424

High resolution collimator system for X-ray detector  

DOE Patents [OSTI]

High resolution in an X-ray computerized tomography (CT) inspection system is achieved by using a collimator/detector combination to limit the beam width of the X-ray beam incident on a detector element to the desired resolution width. In a detector such as a high pressure Xenon detector array, a narrow tapered collimator is provided above a wide detector element. The collimator slits have any desired width, as small as a few mils at the top, the slit width is easily controlled, and they are fabricated on standard machines. The slit length determines the slice thickness of the CT image.

Eberhard, Jeffrey W. (Schenectady, NY); Cain, Dallas E. (Scotia, NY)

1987-01-01T23:59:59.000Z

425

Observation of laser multiple filamentation process and multiple electron beams acceleration in a laser wakefield accelerator  

SciTech Connect (OSTI)

The multiple filaments formation process in the laser wakefield accelerator (LWFA) was observed by imaging the transmitted laser beam after propagating in the plasma of different density. During propagation, the laser first self-focused into a single filament. After that, it began to defocus with energy spreading in the transverse direction. Two filaments then formed from it and began to propagate independently, moving away from each other. We have also demonstrated that the laser multiple filamentation would lead to the multiple electron beams acceleration in the LWFA via ionization-induced injection scheme. Besides, its influences on the accelerated electron beams were also analyzed both in the single-stage LWFA and cascaded LWFA.

Li, Wentao; Liu, Jiansheng; Wang, Wentao; Chen, Qiang; Zhang, Hui; Tian, Ye; Zhang, Zhijun; Qi, Rong; Wang, Cheng; Leng, Yuxin; Li, Ruxin; Xu, Zhizhan [State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, P.O. Box 800-211, Shanghai 201800 (China)] [State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, P.O. Box 800-211, Shanghai 201800 (China)

2013-11-15T23:59:59.000Z

426

Short wavelength laser  

DOE Patents [OSTI]

A short wavelength laser (28) is provided that is driven by conventional-laser pulses (30, 31). A multiplicity of panels (32), mounted on substrates (34), are supported in two separated and alternately staggered facing and parallel arrays disposed along an approximately linear path (42). When the panels (32) are illuminated by the conventional-laser pulses (30, 31), single pass EUV or soft x-ray laser pulses (44, 46) are produced.

Hagelstein, Peter L. (Livermore, CA)

1986-01-01T23:59:59.000Z

427

Laser bottom hole assembly  

DOE Patents [OSTI]

There is provided for laser bottom hole assembly for providing a high power laser beam having greater than 5 kW of power for a laser mechanical drilling process to advance a borehole. This assembly utilizes a reverse Moineau motor type power section and provides a self-regulating system that addresses fluid flows relating to motive force, cooling and removal of cuttings.

Underwood, Lance D; Norton, Ryan J; McKay, Ryan P; Mesnard, David R; Fraze, Jason D; Zediker, Mark S; Faircloth, Brian O

2014-01-14T23:59:59.000Z

428

LaserFest Celebration  

SciTech Connect (OSTI)

LaserFest was the yearlong celebration, during 2010, of the 50th anniversary of the demonstration of the first working laser. The goals of LaserFest were: to highlight the impact of the laser in its manifold commercial, industrial and medical applications, and as a tool for ongoing scientific research; to use the laser as one example that illustrates, more generally, the route from scientific innovation to technological application; to use the laser as a vehicle for outreach, to stimulate interest among students and the public in aspects of physical science; to recognize and honor the pioneers who developed the laser and its many applications; to increase awareness among policymakers of the importance of R&D funding as evidenced by such technology as lasers. One way in which LaserFest sought to meet its goals was to encourage relevant activities at a local level all across the country -- and also abroad -- that would be identified with the larger purposes of the celebration and would carry the LaserFest name. Organizers were encouraged to record and advertise these events through a continually updated web-based calendar. Four projects were explicitly detailed in the proposals: 1) LaserFest on the Road; 2) Videos; 3) Educational material; and 4) Laser Days.

Dr. Alan Chodos; Elizabeth A. Rogan

2011-08-25T23:59:59.000Z

429

Proton emission imaging of the nuclear burn in inertial confinement fusion experiments  

E-Print Network [OSTI]

A proton core imaging system has been developed and extensively used for measuring the nuclear burn regions of inertial confinement fusion implosions. These imaging cameras, mounted to the 60-beam OMEGA laser facility, use ...

DeCiantis, Joseph Loreto

2005-01-01T23:59:59.000Z

430

Higher signal harmonics, LISA's angular resolution, and dark energy  

E-Print Network [OSTI]

It is generally believed that the angular resolution of the Laser Interferometer Space Antenna (LISA) for binary supermassive black holes (SMBH) will not be good enough to identify the host galaxy or galaxy cluster. This conclusion, based on using only the dominant harmonic of the binary SMBH signal, changes substantially when higher signal harmonics are included in assessing the parameter estimation problem. We show that in a subset of the source parameter space the angular resolution increases by more than a factor of 10, thereby making it possible for LISA to identify the host galaxy/galaxy cluster. Thus, LISA's observation of certain binary SMBH coalescence events could constrain the dark energy equation of state to within a few percent, comparable to the level expected from other dark energy missions.

K. G. Arun; Bala R. Iyer; B. S. Sathyaprakash; Siddhartha Sinha; Chris Van Den Broeck

2007-10-24T23:59:59.000Z

431

Tagged Neutron Source for API Inspection Systems with Greatly Enhanced Spatial Resolution  

SciTech Connect (OSTI)

We recently developed induced fission and transmission imaging methods with time- and directionally-tagged neutrons offer new capabilities for characterization of fissile material configurations and enhanced detection of special nuclear materials (SNM). An Advanced Associated Particle Imaging (API) generator with higher angular resolution and neutron yield than existing systems is needed to fully exploit these methods.

None

2012-06-04T23:59:59.000Z

432

Energy Resolved High Resolution Dynamic E-Cell Materials Research. Final Report  

SciTech Connect (OSTI)

The purpose of this project was to develop in situ materials reaction observation capability in an intermediate voltage high resolution transmission electron microscope. To accomplish this we purchased a GATAN imaging energy filter system, a hot stage, and designed and constructed an environmental cell and real time television image recording system, and installed this equipment on our EM 430 intermediate voltage electron microscope.

Carpenter, Ray; Sharma, Renu; Mayer, James

2000-05-16T23:59:59.000Z

433

Scene Reconstruction from High Spatio-Angular Resolution Light Fields Changil Kim1,2  

E-Print Network [OSTI]

Scene Reconstruction from High Spatio-Angular Resolution Light Fields Changil Kim1,2 Henning Zimmer Figure 1: Our method reconstructs accurate depth from light fields of complex scenes. The images on the left show a 2D slice of a 3D input light field, a so called epipolar-plane image (EPI), and two out

Zimmer, Henning

434

High-Resolution Crack Imaging Reveals Degradation Processes in...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Reveals Degradation Processes in Nuclear Reactor Structural Materials. Abstract: Corrosion and cracking represent critical failure mechanisms for structural materials in many...

435

Image Super-Resolution for Improved Automatic Target Recognition  

E-Print Network [OSTI]

Waagenb and Mary Cassabaumb aRice University, Houston, TX bRaytheon Missile Systems, Tucson, AZ ABSTRACT@rice.edu, DW: donald e waagen@raytheon.com, MC: mlcassabaum@raytheon.com #12;Figure 1. Example sub

436

Super-Resolution Fluorescence Nanoscopy Applied to Image Core...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

state of the photoswitching dyes do not absorb at wavelength of the fluorescence excitation. As a result, almost all the interfering fluorophores can be photobleached by the...

437

Image super-resolution by TV-regularization Antonio Marquina  

E-Print Network [OSTI]

of a small region is related to the true intensities of a neighborhood of a pixel through a degradation for which the previous degradation effects are removed from the acquired signal. The super, 50, 46100-Burjassot, Spain, e-mail: marquina@uv.es Department of Mathematics, University

Soatto, Stefano

438

Imaging molecular adsorbates: Resolution effects and determination of adsorption parameters  

E-Print Network [OSTI]

azulene. and various methylazulenes, the details of the observed shapes permitted the identification- pared either by sequential dosing or by dosing from a mix- ture of bulk materials. Further details performed with positive sample bias. ranging from 0.05 to 1.5 Y, with tunneling currents of 0.5-4 n

Chiang, Shirley

439

Photoswitchable Nanoparticles Enable High-Resolution Cell Imaging: PULSAR  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 - September 2006 TheStevenAdministrationPhotometric(dmpe =Photos

440

ICORE: Image Co-addition with Optional Resolution Enhancement  

E-Print Network [OSTI]

Masci * Implemented QA plot files. * Included ­wf option to control inverse variance weighting. When on. There is no warranty that the software described herein is free of bugs. This includes proper graceful program WCS and distortion keys). * Implemented auto-tiling option to support memory management for outlier

Masci, Frank

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Technique Recovers Atomic Resolution in Spectrum Images | ornl.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security AdministrationcontrollerNanocrystallineForeign ObjectOUR8,Materials Characterization Technique Recovers

442

High-Resolution Crack Imaging Reveals Degradation Processes in Nuclear  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation ProposedUsingFun withconfinement plasmas in thein theSurfactant-Assisted Fabrication. |Reactor

443

Nanometer Resolution Imaging by SIngle Molecule Switching. | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the Contributions andData andFleet TestAccounts

444

High Resolution Imaging Science Experiment | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth's Heat Jump to:Photon Place:NetHealthHigganum, Connecticut: EnergyMesaExperiment

445

X-ray laser  

DOE Patents [OSTI]

An X-ray laser (10) that lases between the K edges of carbon and oxygen, i.e. between 44 and 23 Angstroms, is provided. The laser comprises a silicon (12) and dysprosium (14) foil combination (16) that is driven by two beams (18, 20) of intense line focused (22, 24) optical laser radiation. Ground state nickel-like dysprosium ions (34) are resonantly photo-pumped to their upper X-ray laser state by line emission from hydrogen-like silicon ions (32). The novel X-ray laser should prove especially useful for the microscopy of biological specimens.

Nilsen, Joseph (Livermore, CA)

1991-01-01T23:59:59.000Z

446

Laser sources and techniques for spectroscopy and dynamics  

SciTech Connect (OSTI)

This program focuses on the development of novel laser and spectroscopic techniques in the IR, UV, and VUV regions for studying combustion related molecular dynamics at the microscopic level. Laser spectroscopic techniques have proven to be extremely powerful in the investigation of molecular processes which require very high sensitivity and selectivity. The authors approach is to use quantum electronic and non-linear optical techniques to extend the spectral coverage and to enhance the optical power of ultrahigh resolution laser sources so as to obtain and analyze photoionization, fluorescence, and photoelectron spectra of jet-cooled free radicals and of reaction products resulting from unimolecular and bimolecular dissociations. New spectroscopic techniques are developed with these sources for the detection of optically thin and often short-lived species. Recent activities center on regenerative amplification of high resolution solid-state lasers, development of tunable high power mid-IR lasers and short-pulse UV/VUV tunable lasers, and development of a multipurpose high-order suppressor crossed molecular beam apparatus for use with synchrotron radiation sources. This program also provides scientific and technical support within the Chemical Sciences Division to the development of LBL`s Combustion Dynamics Initiative.

Kung, A.H. [Lawrence Berkeley Laboratory, CA (United States)

1993-12-01T23:59:59.000Z

447

Laser micro-processing of silicon using nanosecond pulse shaped fibre laser at 1 ?m wavelength  

E-Print Network [OSTI]

). ............................................................................... 11 Figure 2.2(a): Schematic and (b) SEM image of 19.8% efficient multicrystalline silicon solar cell with “honeycomb” surface texturing (Zhao, Wang et al. 1998). (c) The “inverted pyramid” texture on the top surface (Zhao, Wang et al. 1995). (d) A... is 40 µm (Tan 2006). (c): SEM image of silicon machined by frequency tripled Nd: YAG laser (355 nm) followed by cleaning in the KOH solution (Chen and Darling 2005). (d) Profiles and SEM images (×1.5 k) of ablated a-Si under different irradiation...

Li, Kun

2012-06-12T23:59:59.000Z

448

Drop shaping by laser-pulse impact  

E-Print Network [OSTI]

We study the hydrodynamic response of a falling drop hit by a laser pulse. Combining high-speed with stroboscopic imaging we report that a millimeter-sized dyed water drop hit by a milli-Joule nanosecond laser-pulse deforms and propels forward at several meters per second, until it eventually fragments. We show that the drop motion results from the recoil momentum imparted at the drop surface by water vaporization. We measure the propulsion speed and the time-deformation law of the drop, complemented by boundary integral simulations. We explain the drop propulsion and shaping in terms of the laser pulse energy and drop surface tension. These findings are crucial for the generation of extreme ultraviolet (EUV) light in lithography machines.

Klein, Alexander L; Visser, Claas Willem; Lhuissier, Henri; Sun, Chao; Snoeijer, Jacco H; Villermaux, Emmanuel; Lohse, Detlef; Gelderblom, Hanneke

2015-01-01T23:59:59.000Z

449

THREE-DIMENSIONAL IMAGING OF NANOSCALE MATERIALS BY UISNG COHERENT X-RAYS  

SciTech Connect (OSTI)

X-ray crystallography is currently the primary methodology used to determine the 3D structure of materials and macromolecules. However, many nanostructures, disordered materials, biomaterials, hybrid materials and biological specimens are noncrystalline and, hence, their structures are not accessible by X-ray crystallography. Probing these structures therefore requires the employment of different approaches. A very promising technique currently under rapid development is X-ray diffraction microscopy (or lensless imaging), in which the coherent X-ray diffraction pattern of a noncrystalline specimen is measured and then directly phased to obtain a high-resolution image. Through the DOE support over the past three years, we have applied X-ray diffraction microscopy to quantitative imaging of GaN quantum dot particles, and revealed the internal GaN-Ga2O3 core shell structure in three dimensions. By exploiting the abrupt change in the scattering cross-section near electronic resonances, we carried out the first experimental demonstration of resonant X-ray diffraction microscopy for element specific imaging. We performed nondestructive and quantitative imaging of buried Bi structures inside a Si crystal by directly phasing coherent X-ray diffraction patterns acquired below and above the Bi M5 edge. We have also applied X-ray diffraction microscopy to nondestructive imaging of mineral crystals inside biological composite materials - intramuscular fish bone - at the nanometer scale resolution. We identified mineral crystals in collagen fibrils at different stages of mineralization and proposed a dynamic mechanism to account for the nucleation and growth of mineral crystals in the collagen matrix. In addition, we have also discovered a novel 3D imaging modality, denoted ankylography, which allows for complete 3D structure determination without the necessity of sample titling or scanning. We showed that when the diffraction pattern of a finite object is sampled at a sufficiently fine scale on the Ewald sphere, the 3D structure of the object is determined by the 2D spherical pattern. We confirmed the theoretical analysis by performing 3D numerical reconstructions of a sodium silicate glass structure at 2 Ã? resolution from a 2D spherical diffraction pattern alone. As X-ray free electron lasers are under rapid development worldwide, ankylography may open up a new horizon to obtain the 3D structure of a non-crystalline specimen from a single pulse and allow time-resolved 3D structure determination of disordered materials.

Jianwei Miao

2011-04-18T23:59:59.000Z

450

High Spatial Resolution Observations of Loops in the Solar Corona  

E-Print Network [OSTI]

Understanding how the solar corona is structured is of fundamental importance to determining how the Sun's upper atmosphere is heated to high temperatures. Recent spectroscopic studies have suggested that an instrument with a spatial resolution of 200km or better is necessary to resolve coronal loops. The High Resolution Coronal Imager (Hi-C) achieved this performance on a rocket flight in July 2012. We use Hi-C data to measure the Gaussian widths of 91 loops observed in the solar corona and find a distribution that peaks at about 270km. We also use Atmospheric Imaging Assembly (AIA) data for a subset of 79 of these loops and find that their temperature distributions are narrow. These observations provide further evidence that loops in the solar corona are structured at a scale of several hundred kilometers, well above the spatial scale of proposed physical mechanisms.

Brooks, David H; Ugarte-Urra, Ignacio; Winebarger, Amy R

2013-01-01T23:59:59.000Z

451

HIGH SPATIAL RESOLUTION OBSERVATIONS OF LOOPS IN THE SOLAR CORONA  

SciTech Connect (OSTI)

Understanding how the solar corona is structured is of fundamental importance to determine how the Sun's upper atmosphere is heated to high temperatures. Recent spectroscopic studies have suggested that an instrument with a spatial resolution of 200 km or better is necessary to resolve coronal loops. The High Resolution Coronal Imager (Hi-C) achieved this performance on a rocket flight in 2012 July. We use Hi-C data to measure the Gaussian widths of 91 loops observed in the solar corona and find a distribution that peaks at about 270 km. We also use Atmospheric Imaging Assembly data for a subset of these loops and find temperature distributions that are generally very narrow. These observations provide further evidence that loops in the solar corona are often structured at a scale of several hundred kilometers, well above the spatial scale of many proposed physical mechanisms.

Brooks, David H.; Ugarte-Urra, Ignacio [College of Science, George Mason University, 4400 University Drive, Fairfax, VA 22030 (United States); Warren, Harry P. [Space Science Division, Naval Research Laboratory, Washington, DC 20375 (United States); Winebarger, Amy R. [NASA Marshall Space Flight Center, ZP 13, Huntsville, AL 35812 (United States)

2013-08-01T23:59:59.000Z

452

Study of Fuzzy based Classifier Parameter across Spatial Resolution  

E-Print Network [OSTI]

Classification and interpretation of satellite images are complex processes and that may be affected by various factors. Most fuzzy based soft classification techniques have been used to provide a more appropriate and accurate area estimation when fine, medium and coarse spatial resolution data are being used. Spatial resolution determines the spatial details on the Earth surface and greatly reduces the problem of mixed pixel. This paper examines the effect of weighting exponent „m ? parameter of fuzzy c-means (FCM) and possibilistic c-mean (PCM) classifiers with respect to entropy, an uncertainty indicator for different extracted classes. This paper measures uncertainty variations across spatial resolution for different class extraction. Uncertainty can be defined as skepticism wherein entropy is an absolute indicator of an

Rakesh Dwivedi; S. K. Ghosh

453

Laser-direct-driven quasi-isentropic experiments on aluminum  

SciTech Connect (OSTI)

Laser-direct-driven ramp compression experiments were performed on long temporally shaped laser pulses based on an analytical isentropic compression model. Upper pressure limits, the ablation pressure scaling law, and stress-density curves were studied. The validity of the analytical model used, the ablation pressure scaling law, and the phenomena of missing line-imaging velocity interferometer (VISAR) fringes in the experimental results are discussed.

Xue, Quanxi, E-mail: quanxixue@163.com [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); State Key Laboratory of Laser Interaction with Matter, Northwest Institute of Nuclear Technology, Xi'an 710024 (China); Wang, Zhebin; Jiang, Shaoen, E-mail: jiangshn@vip.sina.com; Wang, Feng [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Ye, Xisheng; Liu, Jingru [State Key Laboratory of Laser Interaction with Matter, Northwest Institute of Nuclear Technology, Xi'an 710024 (China)

2014-07-15T23:59:59.000Z

454

Few-cycle optical probe-pulse for investigation of relativistic laser-plasma interactions  

SciTech Connect (OSTI)

The development of a few-cycle optical probe-pulse for the investigation of laser-plasma interactions driven by a Ti:sapphire, 30 Terawatt (TW) laser system is described. The probe is seeded by a fraction of the driving laser's energy and is spectrally broadened via self-phase modulation in a hollow core fiber filled with a rare gas, then temporally compressed to a few optical cycles via chirped mirrors. Shadowgrams of the laser-driven plasma wave created in relativistic electron acceleration experiments are presented with few-fs temporal resolution, which is shown to be independent of post-interaction spectral filtering of the probe-beam.

Schwab, M. B.; Sävert, A.; Polz, J.; Schnell, M.; Rinck, T.; Möller, M.; Hansinger, P. [Insitut für Optik und Quantenelektronik, Max-Wien-Platz 1, 07743 Jena (Germany)] [Insitut für Optik und Quantenelektronik, Max-Wien-Platz 1, 07743 Jena (Germany); Jäckel, O.; Paulus, G. G.; Kaluza, M. C. [Insitut für Optik und Quantenelektronik, Max-Wien-Platz 1, 07743 Jena (Germany) [Insitut für Optik und Quantenelektronik, Max-Wien-Platz 1, 07743 Jena (Germany); Helmholtz-Institut Jena, Fröbelstieg 3, 07743 Jena (Germany); Veisz, L. [Max-Planck-Institut für Quantenoptik, Hans-Kopfermann-Straße 1, 85748 Garching (Germany)] [Max-Planck-Institut für Quantenoptik, Hans-Kopfermann-Straße 1, 85748 Garching (Germany)

2013-11-04T23:59:59.000Z

455

Characterization of the Los Alamos IPG YLR-6000 fiber laser using multiple optical paths and laser focusing optics  

SciTech Connect (OSTI)

Fiber laser technology has been identified as the replacement power source for the existing Los Alamos TA-55 production laser welding system. An IPG YLR-6000 fiber laser was purchased, installed at SM-66 R3, and accepted in February 2008. No characterization of the laser and no welding was performed in the Feb 2008 to May 2009 interval. T. Lienert and J. Bernal (Ref. 1, July 2009) determined the existing 200 mm Rofin collimator and focus heads used with the Rofin diode pumped lasers were inadequate for use with the IPG laser due to clipping of the IPG laser beam. Further efforts in testing of the IPG laser with Optoskand fiber delivery optics and a Rofin 120 mm collimator proved problematic due to optical fiber damage. As a result, IPG design optical fibers were purchased as replacements for subsequent testing. Within the same interval, an IPG fiber-to-fiber (F2F) connector, custom built for LANL, (J. Milewski, S. Gravener, Ref.2) was demonstrated and accepted at IPG Oxford, MA in August 2009. An IPG service person was contracted to come to LANL to assist in the installation, training, troubleshooting and characterization of the multiple beam paths and help perform laser head optics characterization. The statement of work is provided below: In summary the laser system, optical fibers, F2F connector, Precitec head, and a modified Rofin type (w/120mm Optoskand collimator) IWindowIBoot system focus head (Figure 1) were shown to perform well at powers up to 6 kW CW. Power measurements, laser spot size measurements, and other characterization data and lessons learned are contained within this report. In addition, a number of issues were identified that will require future resolution.

Milewski, John O [Los Alamos National Laboratory; Bernal, John E [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

456

Test Images  

E-Print Network [OSTI]

Test Images. I hope to have a set of test images for the course soon. Some images are available now; some will have to wait until I can find another 100-200

457

Laser system using ultra-short laser pulses  

DOE Patents [OSTI]

A laser system using ultrashort laser pulses is provided. In another aspect of the present invention, the system includes a laser, pulse shaper and detection device. A further aspect of the present invention employs a femtosecond laser and binary pulse shaping (BPS). Still another aspect of the present invention uses a laser beam pulse, a pulse shaper and a SHG crystal.

Dantus, Marcos (Okemos, MI); Lozovoy, Vadim V. (Okemos, MI); Comstock, Matthew (Milford, MI)

2009-10-27T23:59:59.000Z

458

Directed evolution of a magnetic resonance imaging contrast agent for noninvasive imaging of dopamine  

E-Print Network [OSTI]

The development of molecular probes that allow in vivo imaging of neural signaling processes with high temporal and spatial resolution remains challenging. Here we applied directed evolution techniques to create magnetic ...

Shapiro, Mikhail G.

459

Predicting threshold and location of laser damage on optical surfaces  

DOE Patents [OSTI]

Disclosed is an apparatus useful in the prediction of the damage threshold of various optical devices, the location of weak spots on such devices and the location, identification, and elimination of optical surface impurities. The apparatus comprises a focused and pulsed laser, a photo electric detector/imaging means, and a timer. The weak spots emit photoelectrons when subjected to laser intensities that are less than the intensity actually required to produce the damage. The weak spots may be eliminated by sustained exposure to the laser beam.

Siekhaus, W.

1985-02-04T23:59:59.000Z

460

Image Analysis  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Recognition Image Analysis and Recognition Snapshot1498121slicesqResedison Fibers permeating imaged material (Courtesy: Bale, Loring, Perciano and Ushizima) Imagery coming from...

Note: This page contains sample records for the topic "resolution laser imaging" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Laser diagnostics on a hypersonic combustor  

SciTech Connect (OSTI)

NASA-Langley has implemented a laser-based multipoint/multiparameter diagnostics system at its hypersonic direct-connect combustor, in order to measure both temperature and majority species densities in two dimensions, using spatially-scanned CARS; in addition, line-imaged measurements of radical densities are simultaneously generated by LIF at any of several planes downstream of the fuel injector. Initial experimental trials have demonstrated successful detection of one-dimensional images of OH density, as well as CARS N2-temperature measurements, in the turbulent reaction zone of the hypersonic combustor.

Taylor, D.J.; Oldenborg, R.C.; Tiee, J.J.; Northam, G.B.; Antcliff, R.R.; Cutler, A.D.; Jarrett, O.; Smith, M.W. (Los Alamos National Laboratory, NM (USA) NASA, Langley Research Center, Hampton, VA (USA))

1991-01-01T23:59:59.000Z

462

LASER SAFETY POLICY Policy Statement  

E-Print Network [OSTI]

LASER SAFETY POLICY Policy Statement Each department that acquires or operates lasers for use in laboratories or research is responsible for reporting laser acquisition to the Office of Laboratory Safety, selecting a departmental deputy laser safety officer, mandating training for its laser operators

Vertes, Akos

463

Characteristic x-ray emission from undermines plasmas irradiated by ultra-intense lasers  

SciTech Connect (OSTI)

Between FY09 and FY11 we have conducted more than a dozen three-week experimental campaigns at high-power laser facilities around the world to investigate laser-channeling through x-ray and optical imaging and the conversion from laser-energy to xrays. We have performed simultaneous two-wavelength x-ray imaging (K-alpha and He-alpha) to distinguish the hot-plasma region (hot-spot) from the laser-produced electrons (K-alpha). In addition, we have initiated a new collaboration with SNL and have performed first shots on the 100 TW beamlet chamber to commission a fast x-ray streak camera to be used to investigate the temporal evolution of our K-alpha sources. We also collaborated on campaigns at the Rutherford Appleton Laboratory (UK) and the LANL Trident laser to employ laser produced x-ray sources for Thomson scattering off dense matter.

Niemann, Christoph

2012-05-05T23:59:59.000Z

464

Dielectric microscopy with submillimeter resolution  

E-Print Network [OSTI]

In analogy with optical near-field scanning methods, we use tapered dielectric waveguides as probes for a millimeter wave vector network analyzer. By scanning thin samples between two such probes we are able to map the spatially varying dielectric properties of materials with sub-wavelength resolution; using a 150 GHz probe in transmision mode we see spatial resolution of around 500 microns. We have applied this method to a variety of highly heterogeneous materials. Here we show dielectric maps of granite and oil shale.

Nathan S. Greeney; John A. Scales

2007-06-20T23:59:59.000Z

465

Quantitative strain mapping of InAs/InP quantum dots with 1 nm spatial resolution using dark field electron holography  

E-Print Network [OSTI]

by geometrical phase analysis of high angle annular dark field scanning transmission electron microscopy images resolution images have been used to obtain the strain in nano-structured materials.3 Although this approach in many different types of sam- ples, at this time the spatial resolution of between 3 and 6 nm

Dunin-Borkowski, Rafal E.

466

Laser-PlasmaWakefield Acceleration with Higher Order Laser Modes  

E-Print Network [OSTI]

Design considerations for a laser-plasma linear collider,"E.Esarey, and W.P.Leemans, "Free-electron laser driven bythe LBNL laser-plasma accelerator," in Proc. Adv. Acc. Con.

Geddes, C.G.R.

2011-01-01T23:59:59.000Z

467

Spatial Gradients in Particle Reinforced Polymers Characterized by X-Ray Attenuation and Laser Confocal Microscopy  

SciTech Connect (OSTI)

The goal of this work is to develop techniques for measuring gradients in particle concentration within filled polymers, such as encapsulant. A high concentration of filler particles is added to such materials to tailor physical properties such as thermal expansion coefficient. Sedimentation and flow-induced migration of particles can produce concentration gradients that are most severe near material boundaries. Therefore, techniques for measuring local particle concentration should be accurate near boundaries. Particle gradients in an alumina-filled epoxy resin are measured with a spatial resolution of 0.2 mm using an x-ray beam attenuation technique, but an artifact related to the finite diameter of the beam reduces accuracy near the specimen's edge. Local particle concentration near an edge can be measured more reliably using microscopy coupled with image analysis. This is illustrated by measuring concentration profiles of glass particles having 40 {micro}m median diameter using images acquired by a confocal laser fluorescence microscope. The mean of the measured profiles of volume fraction agrees to better than 3% with the expected value, and the shape of the profiles agrees qualitatively with simple theory for sedimentation of monodisperse particles. Extending this microscopy technique to smaller, micron-scale filler particles used in encapsulant for microelectronic devices is illustrated by measuring the local concentration of an epoxy resin containing 0.41 volume fraction of silica.

LAGASSE,ROBERT R.; THOMPSON,KYLE R.

2000-06-12T23:59:59.000Z

468