1

Energy performance listings: Residential refrigerator/freezers  

SciTech Connect (OSTI)

The Energy Performance Listings series provides comparative information across manufacturers on products. The Refrigerator/Freezers Listings include more than 2900 models that meet or exceed federal standards contained in the Energy Conservation Program for Consumer Products. Information on model energy efficiency levels, performance characteristics, and manufacturer names permits easy selection of top-performing equipment. Each Energy Performance Listing includes an introductory section, two sections of model listings, and an appendix with manufacturer contacts. The first model-listing section presents information in descending order of efficiency for all manufacturers. These efficiency-ordered listings also include banners or symbols to identify voluntary efficiency thresholds for U.S. DOE/U.S. EPA`s Energy Star Program and U.S. DOE`s Federal Energy Management Program (FEMP). Products listed above each banner meet or exceed the efficiency level established by the Energy Star program. All models noted with the symbol meet or exceed FEMP levels. With these listings, users can quickly identify the most efficient product in a particular size range, identify products that meet the efficiency criteria of a specific program, or determine an efficiency threshold that will include a specific number of manufacturers. The second section of model listings presents products grouped by manufacturer and catalog number, allowing users to quickly find and identify performance information on specific models. Energy Performance Listings are tools that support purchasing and procurement by federal, state, and local governments and others, including utility companies, energy interest groups, and research organizations. The listings may be used for program design and planning purposes, equipment selection, specification, and purchasing decisions. The listings are a product of the Energy-Efficient Procurement Collaborative, Inc. and are available through NYSERDA.

NONE

1997-01-01T23:59:59.000Z

2

Synopsis of residential refrigerator/freezer alternative refrigerants evaluation  

SciTech Connect (OSTI)

The experimental testing on residential refrigerator/freezers (R/Fs) is summarized in this paper. R/F testing focused on two areas: alternative refrigerants and equipment configurations. The refrigerants evaluated consisted of single components, azeotropes, and zeotropes derived from hydrofluorocarbons (HFCs) and hydrocarbons (HCs). These refrigerants were evaluated in conventional and unconventional R/F designs. Major and minor design modifications were studied. Minor modifications consisted of various capillary tube lengths, door insulations, and compressors, while major modifications included two-evaporator and two-cycle R/F systems. Results obtained from testing the two-cycle system will be discussed in a later paper. This paper presents the experimental results of alternative technologies evaluated as replacements for ozone depleting chemicals.

Baskin, E. [Environmental Protection Agency, Research Triangle Park, NC (United States)

1998-12-31T23:59:59.000Z

3

Energy-efficiency directory of refrigerators and refrigerator-freezers  

SciTech Connect (OSTI)

Information is presented about the energy costs of operating refrigerators and refrigerator-freezers and includes the type of refrigerator or refrigerator-freezer, the fresh food volume, the freezer volume, the total volume, and the yearly energy cost. The directory lists all currently marketed electric refrigerators and refrigerator-freezers that have Energy Guide labels. The Federal Trade Commission requires manufacturers who distribute refrigerators and refrigerator-freezers to attach Energy Guide labels to appliances manufactured on or after May 19, 1980. The data have been measured by manufacturers and/or their agents according to US Government standard test procedures.

Statt, T.G.; Coggins, J.L.

1981-06-01T23:59:59.000Z

4

Refrigerator/freezer energy use: Measured values vs. simulation results  

SciTech Connect (OSTI)

The EPA Refrigerator Analysis (ERA) program was utilized in the engineering analysis performed to support the proposed refrigerator/freezer standards in the United States. In this paper the accuracy of the ERA program for predicting the energy consumption of domestic refrigerators, freezers, and refrigerator-freezers is studied by comparing the predicted energy consumption with the measured energy consumption.

Hakim, S.H.; Turiel, I. [Lawrence Berkeley National Lab., CA (United States). Energy and Environment Div.

1997-12-31T23:59:59.000Z

5

DEVELOPMENT OF A HIGH EFFICIENCY, AUTOMATIC DEFROSTING REFRIGERATOR-FREEZER  

E-Print Network [OSTI]

#12;DEVELOPMENT OF A HIGH EFFICIENCY, AUTOMATIC DEFROSTING REFRIGERATOR-FREEZER Richard F. Topping-efficient refrigerator- freezer prototype involving the Department of Energy's Oak Ridge National Laboratory, Arthur D refrigerator-freezers. The resulting 16 cubic foot prototype uses significantly less energy than the most

Oak Ridge National Laboratory

6

Refrigerator-freezer energy testing with alternative refrigerants  

SciTech Connect (OSTI)

As a result of the Montreal Protocol that limits the production of ozone-depleting refrigerants, manufacturers are searching for alternatives to replace the R12 that is presently used in residential refrigerator-freezers. Before an alternative can be selected, several issues must be resolved. Among these are energy impacts, system compatibility, cost, and availability. In an effort to determine the energy impacts of some of the alternatives, energy consumption tests were performed in accordance with section 8 of the Association of Home Appliance Manufacturers (AHAM) standard for household refrigerators and household freezers. The results are presented for an 18 cubic foot (0.51 cubic meter), top-mount refrigerator-freezer with a static condenser using the following refrigerants: R12, R500, R12/Dimethyl-ether (DME), R22/R142b, and R134a. Conclusions from the AHAM test are that R500 and R12 /DME have a reduced energy consumption relative to R12 when replaced in the test unit with no modifications to the refrigeration system. Run times were slightly lower than R12 for both refrigerants indicating a higher capacity. While the R134a and R22/R142b results were less promising refrigeration system, such as a different capillary tube or compressor, may improve their performance. 12 refs., 2 figs., 3 tabs.

Vineyard, E.A.; Sand, J.R.; Miller, W.A.

1989-01-01T23:59:59.000Z

7

End-Use Load and Consumer Assessment Program: Analysis of residential refrigerator/freezer performance  

SciTech Connect (OSTI)

The Bonneville Power Administration (Bonneville) is conducting a large end-use data acquisition program in an effort to understand how energy is utilized in buildings with permanent electric space heating equipment in the Pacific Northwest. The initial portion of effort, known as the End-Use Load and Consumer Assessment Program (ELCAP), was conducted for Bonneville by the Pacific Northwest Laboratory (PNL). The collection of detailed end-use data provided an opportunity to analyze the amount of energy consumed by both refrigerators and separate freezers units located in residential buildings. By obtaining this information, the uncertainty of long- term regional end-use forecasting can be improved and potential utility marketing programs for new appliances with a reduced overall energy demand can be identified. It was found that standby loads derived from hourly averages between 4 a.m. and 5 a.m. reflected the minimum consumption needed to maintain interior refrigerator temperatures at a steady-state condition. Next, an average 24-hour consumption that included cooling loads from door openings and cooling food items was also determined. Later, analyses were conducted to develop a model capable of predicting refrigerator standby loads and 24-hour consumption for comparison with national refrigerator label ratings. Data for 140 residential sites with a refrigeration end-use were screened to develop a sample of 119 residences with pure refrigeration for use in this analysis. To identify those refrigerators that were considered to be pure (having no other devices present on the circuit) in terms of their end-use classification, the screening procedure used a statistical clustering technique that was based on standby loads with 24-hour consumption. 5 refs., 18 figs., 4 tabs.

Ross, B.A.

1991-09-01T23:59:59.000Z

8

Refrigerator-freezer energy testing with alternative refrigerants  

SciTech Connect (OSTI)

As a result of the Montreal Protocol (UNEP 1987) that limits the production of ozone-depleting refrigerants, manufacturers are searching for alternatives to replace the R12 that is presently used in residential refrigerator-freezers. Before an alternative can be selected, several issues must resolved. Among these are energy impacts, system compatibility, cost, and availability, In an effort to determine the energy impacts of some of the alternatives, energy consumption tests were performed in accordance with section 8 of the Association of Home Appliance Manufacturers (AHAM) standard for household refrigerators and household freezers (AHAM 1985). The results are presented for an 18 ft{sup 3} (0.51 m{sup 3}), top mount refrigerators-freezer with a static condenser using the following refrigerants: R 12, R500, R12/dimethylether (DME), R22/R142b, and R134a. Conclusions from the AHAM test are that R500 and R12/DME have a reduced energy consumption relative to R12 when replaced in the test unit with no modifications to the refrigeration system. Run times were slightly lower than R12 for both refrigerants, indicating a higher capacity. While the R134a and R22/R142b results were less promising (6.8% and 8.5% higher energy consumption, respectively), changes to the refrigeration system, such as a different capillary tube or compressor, may improve their performance. It is noted that the test results are only an initial step in determining a replacement for R12.

Sand, J.R. (Oak Ridge National Lab., Oak Ridge, TN (US)); Vineyard, E.A.; Sand, J.R.

1989-01-01T23:59:59.000Z

9

Realized and Projected Impacts of U.S. Energy Efficiency Standards for Residential and Commercial Appliances  

E-Print Network [OSTI]

Refrigerators, Refrigerator-Freezers, and Freezers,and Updates RESIDENTIAL Refrigerators Freezers Central Aira given year for refrigerators, freezers, clothes washers,

Meyers, Stephen P.

2008-01-01T23:59:59.000Z

10

Performance of a two-cycle refrigerator/freezer using HFC refrigerants  

SciTech Connect (OSTI)

A two-cycle 18 ft{sup 3} (0.51 m{sup 3}) refrigerator/freezer was tested utilizing American National Standards Institute/Association of Home Appliance Manufacturers (ANSI/AHAM) standards for energy consumption testing. A 34.9% energy consumption reduction was realized for a 1984 model refrigerator/freezer (1020 kWh original energy use). This paper presents a proven method of reducing the current Department of Energy (DOE) minimum energy-efficiency standards for refrigerator/freezers to the proposed year 2001 standards utilizing existing technology. For a top-mount, frost-free refrigerator/freezer having the above volume, the current DOE minimum energy standard is 770 kWh/year, and the proposed DOE year 2001 standard is 530 kWh/year (a 31% reduction). Therefore, some significant reductions may be obtained by implementing the modifications discussed in this paper into newer refrigerator/freezer models. The paper gives an overview of the modifications implemented by a Danish university on a US refrigerator/freezer and presents experimental performance testing results of the refrigerator/freezer. The modifications will cause the refrigerator/freezer to be more expensive, but the performance enhancements should offset cost. No cost analysis is presented in this paper, but a detailed cost analysis of a two-cycle refrigerator/freezer is contained in a 1993 US Environmental Protection Agency (EPA) report (EPA 1993). The refrigerator/freezer was tested using four refrigerants and compressors. Two compressors and refrigerants were tested in the freezer cycle, and four were tested in the fresh food cycle.

Baskin, E.; Delafield, F.R.

1999-07-01T23:59:59.000Z

11

Energy consumption testing of innovative refrigerator-freezers  

SciTech Connect (OSTI)

The high ambient temperature of the Canadian Standards Association (CSA) and the AHAM/DOE Refrigerator-Freezer Energy Consumption Standards is intended to compensate for the lack of door openings and other heat loads. Recently published results by Meier and Jansky (1993) indicate labeled consumption overpredicting typical field consumption by 15%. In-house field studies on conventional models showed labeled consumption overpredicting by about 22%. The Refrigerator-Freezer Technology Assessment (RFTA) test was developed to more accurately predict field consumption. This test has ambient temperature and humidity, door openings, and condensation control set at levels intended to typify Canadian household conditions. It also assesses consumption at exactly defined compartment rating temperatures. Ten conventional and energy-efficient production models were laboratory tested. The RFTA results were about 30% lower than labeled. Similarly, the four innovative refrigerator-freezer models, when field tested, also had an average of 30% lower consumption than labeled. Thus, the results of the limited testing suggest that the RFTA test may be a more accurate predictor of field use. Further testing with a larger sample is recommended. Experimental results also indicated that some innovative models could save up to 50% of the energy consumption compared with similar conventional units. The technologies that contributed to this performance included dual compressors, more efficient compressors and fan motors, off-state refrigerant control valve, fuzzy logic control, and thicker insulation. The larger savings were on limited production models, for which additional production engineering is required for full marketability.

Wong, M.T.; Howell, B.T.; Jones, W.R. [Ontario Hydro Technologies, Toronto, Ontario (Canada); Long, D.L. [Statistical Solutions, Mississauga, Ontario (Canada)

1995-12-31T23:59:59.000Z

12

Product Refrigerator Freezer Fresh, in shell 4 to 5 weeks Don't freeze  

E-Print Network [OSTI]

Product Refrigerator Freezer Eggs Fresh, in shell 4 to 5 weeks Don't freeze Raw yolks, whites 2 recommended storage times are for quality only. Refrigerator & Freezer Storage Chart Product Refrigerator, opened 3 days Don't freeze unopened 10 days 1 year Mayonnaise, commercial Refrigerate after opening 2

Burke, Peter

13

Refrigerator/freezer directory: sorted by type and volume, based on 1979 standards  

SciTech Connect (OSTI)

This directory identifies refrigerators, freezers and combinations thereof, that have been certified as complying with the regulations that became effective on November 3, 1979.

Not Available

1980-02-29T23:59:59.000Z

14

NASA advanced refrigerator/freezer technology development project overview  

SciTech Connect (OSTI)

NASA Lewis Research Center (LeRC) has recently initiated a three-year project to develop the advanced refrigerator/freezer (R/F) technologies needed to support future life and biomedical sciences space experiments. Refrigerator/freezer laboratory equipment, most of which needs to be developed, is enabling to about 75 percent of the planned space station life and biomedical science experiments. These experiments will require five different classes of equipment; three storage freezers operating at -20 C, -70 C and less than 183 C, a -70 C freeze-dryer, and a cryogenic (less than 183 C) quick/snap freezer. This project is in response to a survey of cooling system technologies, performed by a team of NASA scientists and engineers. The team found that the technologies required for future R/F systems to support life and biomedical sciences spaceflight experiments, do not exist at an adequate state of development and concluded that a program to develop the advanced R/F technologies is needed. Limitations on spaceflight system size, mass, and power consumption present a significant challenge in developing these systems. This paper presents some background and a description of the Advanced R/F Technology Development Project, project approach and schedule, general description of the R/F systems, and a review of the major R/F equipment requirements.

Cairelli, J.E.

1995-03-01T23:59:59.000Z

15

New Energy Efficiency Standards for Residential Clothes Washers...  

Office of Environmental Management (EM)

June 2011 - Residential furnaces and residential central air conditioners and heat pumps September 2011 - Residential refrigerators, freezers, and refrigerator-freezers...

16

Factors affecting the energy consumption of two refrigerator-freezers  

SciTech Connect (OSTI)

Two refrigerator-freezers, one with a top-mounted freezer and one with side-by-side doors, were tested in the laboratory to determine the sensitivity of their energy consumption to various operational factors. Room temperature, room humidity, door openings, and the setting of the anti-sweat heater switch were the factors examined. The results indicated that the room temperature and door openings had a significantly greater effect on energy consumption than the other two factors. More detailed tests were then performed under different room temperature and door-opening combinations. The relationship of door openings and the equivalent test room temperature was established. Finally, the effect on energy of different temperature settings was studied. Test results are presented and discussed.

Kao, J.Y.; Kelley, G.E. [National Inst. of Standards and Technology, Gaithersburg, MD (United States). Building and Fire Research Lab.

1996-12-31T23:59:59.000Z

17

9-056-462-00 (3557) EXPLOSION-PROOF REFRIGERATOR, FREEZER  

E-Print Network [OSTI]

, FREEZER AND REFRIGERATOR-FREEZER Models 3557, 3557SS, 3557LHSS, 3557-2, 3557-4 o I At Lab-Line, we take in this manual include: Models 3557, 3557SS, 3557LHSS: Model 3557-2: Freezer Model 3557-4: Refrigerator-Freezer9-056-462-00 (3557) kN 4/88 ^INiyiAL LAB-LIIME lAB-LINE FRIGID-CAB EXPLOSION-PROOF REFRIGERATOR

Kleinfeld, David

18

Field test of a high efficiency, automatic defrost refrigerator-freezer  

SciTech Connect (OSTI)

This paper describes the market evaluation and field test portion of a program to design, develop, and demonstrate a high efficiency, automatic defrosting refrigerator-freezer for the residential market. After the successful completion of Phase I of the program, which concentrated on the design, construction, and laboratory testing of a 453 1 (16 ft/sup 3/) high-efficiency refrigerator-freezer prototype, Phase II was initiated in February 1979 to evaluate the sales potential and performance of the high-efficiency refrigerator concept under field conditions, as a necessary step in creating a product that was both manufacturable and marketable. In Phase I, a survey of food consumption and storage trends, family size, and consumer buying habits led to a sales-weighted average-capacity forecast for 1985 of approximately 453 1 (16 ft/sup 3/) and identification of the top-mount, automatic defrosting refrigerator as the projected sales leader. To meet this market demand, a 453 1 (16 ft/sup 3/) top-mount was selected as the baseline for the Phase I design and development. In Phase II, a 509 1 (18 ft/sup 3/) unit using Phase I technology was chosen for the field test, since the slightly larger model better fit the participating manufacturer's new product development efforts and market.

Topping, R.F.; Vineyard, E.A.

1982-01-01T23:59:59.000Z

19

Review of energy efficiency of refrigerator/freezer gaskets. Final report, Jul-Nov 90  

SciTech Connect (OSTI)

The report gives results of an investigation of the significance of heat leakage through gaskets in household refrigerator/freezers, explores different design features, and suggests further study if necessary. The report gives results of an extensive literature review, interviews with refrigerator/freezer and gasket manufacturers, and some engineering analysis. (NOTE: Home refrigerators are the largest consumers of electricity among household appliances and are consuming an estimated 8% of the total electricity used in the U.S. Recent studies show that gasket area heat leakage may account for as much as 21% of the total thermal load.)

Ghassemi, M.; Shapiro, H.

1991-10-01T23:59:59.000Z

20

Experimental and cost analyses of a one kilowatt-hour/day domestic refrigerator-freezer  

SciTech Connect (OSTI)

Over the past ten years, government regulations for energy standards, coupled with the utility industry`s promotion of energy-efficient appliances, have prompted appliance manufacturers to reduce energy consumption in refrigerator-freezers by approximately 40%. Global concerns over ozone depletion have also required the appliance industry to eliminate CFC-12 and CFC-11 while concurrently improving energy efficiency to reduce greenhouse emissions. In response to expected future regulations that will be more stringent, several design options were investigated for improving the energy efficiency of a conventionally designed, domestic refrigerator-freezer. The options, such as cabinet and door insulation improvements and a high-efficiency compressor were incorporated into a prototype refrigerator-freezer cabinet and refrigeration system. Baseline energy consumption of the original 1996 production refrigerator-freezer, along with cabinet heat load and compressor calorimeter test results, were extensively documented to provide a firm basis for experimentally measured energy savings. The goal for the project was to achieve an energy consumption that is 50% below in 1993 National Appliance Energy Conservation Act (NAECA) standard for 20 ft{sup 3} (570 l) units. Based on discussions with manufacturers to determine the most promising energy-saving options, a laboratory prototype was fabricated and tested to experimentally verify the energy consumption of a unit with vacuum insulation around the freezer, increased door thicknesses, a high-efficiency compressor, a low wattage condenser fan, a larger counterflow evaporator, and adaptive defrost control.

Vineyard, E.A.; Sand, J.R.

1997-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

FIELD TEST OF A HIGH-EFFICIENCY, AUTOMATIC-DEFROST REFRIGERATOR-FREEZER  

E-Print Network [OSTI]

#12;FIELD TEST OF A HIGH-EFFICIENCY, AUTOMATIC- DEFROST REFRIGERATOR-FREEZER By Richard F. Topping and manufacture pre-production units for home usage tests. The purpose of the field test and the associated market been promising. The first five months of field test data have shown an average 57% decrease in energy

Oak Ridge National Laboratory

22

Compressor calorimeter performance of refrigerant blends: Comparative methods and results for a refrigerator/freezer application  

SciTech Connect (OSTI)

A protocol was developed to define calorimeter operating pressures for nonazeotropic refrigerant mixtures (NARMs) which corresponded with the saturated evaporator and condenser temperatures commonly used for pure refrigerants. Compressor calorimeter results were obtained using this equivalent-mean-temperature (EMT) approach and a generally applied Association of Home Appliance Manufacturers (AHAM) procedure at conditions characteristic of a domestic refrigerator-freezer application. Tests with R-12 and two NARMs indicate that compressor volumetric and isentropic efficiencies are nearly the same for refrigerants with similar capacities and pressure ratios. The liquid-line temperature conditions specified in the AHAM calorimeter rating procedure for refrigerator-freezer compressors were found to preferentially derate NARM performance relative to R-12. Conversion of calorimeter data taken with a fixed liquid-line temperature to a uniform minimal level of condenser subcooling is recommended as a fairer procedure when NARMs are involved. Compressor energy-efficiency-ratio (EER) and capacity data measured as a result of the EMT approach were compared to system performance calculated using an equivalent-heat-exchanger-loading (EHXL) protocol based on a Lorenz-Meutzner (L-M) refrigerator-freezer modeling program. The EHXL protocol was used to transform the calorimeter results into a more relevant representation of potential L-M cycle performance. The EMT method used to set up the calorimeter tests and the AHAM liquid-line conditions combined to significantly understate the cycle potential of NARMs relative to that predicted at the more appropriate EHXL conditions. Compressor conditions representative of larger heat exchanger sizes were also found to give a smaller L-M cycle advantage relative to R-12.

Rice, C K; Sand, J R

1993-01-01T23:59:59.000Z

23

Fridge of the future: Designing a one-kilowatt-hour/day domestic refrigerator-freezer  

SciTech Connect (OSTI)

An industry/government Cooperative Research and Development Agreement (CRADA) was established to evaluate and test design concepts for a domestic refrigerator-freezer unit that represents approximately 60% of the US market. The goal of the CRADA was to demonstrate advanced technologies which reduce, by 50 percent, the 1993 NAECA standard energy consumption for a 20 ft{sup 3} (570 I) top-mount, automatic-defrost, refrigerator-freezer. For a unit this size, the goal translated to an energy consumption of 1.003 kWh/d. The general objective of the research was to facilitate the introduction of cost-efficient technologies by demonstrating design changes that can be effectively incorporated into new products. A 1996 model refrigerator-freezer was selected as the baseline unit for testing. Since the unit was required to meet the 1993 NAECA standards, the energy consumption was quite low (1.676 kWh/d), thus making further reductions in energy consumption very challenging. Among the energy saving features incorporated into the original design of the baseline unit were a low-wattage evaporator fan, increased insulation thicknesses, and liquid line flange heaters.

Vineyard, E.A.; Sand, J.R.

1998-03-01T23:59:59.000Z

24

Energy efficiency improvements for refrigerator/freezers using prototype doors containing gas-filled panel insulating systems  

SciTech Connect (OSTI)

Energy efficiency improvements in domestic refrigerator/freezers, are directly influenced by the overall thermal performance of the cabinet and doors. An advanced system for reducing heat gain is Gas-Filled Panel thermal insulation technology. Gas-Filled Panels contain a low-conductivity, inert gas at atmospheric pressure and employ a reflective baffle to suppress radiation and convection within the gas. This paper presents energy use test results for a 1993 model 500 liter top mount refrigerator/freezer operated with its original doors and with a series of alternative prototype doors. Gas-Filled Panel technology was used in two types of prototype refrigerator/freezer doors. In one design, panels were used in composite with foam in standard metal door pans; this design yielded no measurable energy savings. In the other design, special polymer door pans were fitted with panels that fill nearly all of the available insulation volume; this design yielded a 6.5% increase in energy efficiency for the entire refrigerator/freezer. The EPA Refrigerator Analysis computer program has been used to predict the change in daily energy consumption with the alternative doors. The computer model also projects a 25% energy efficiency improvement for a refrigerator/freezer that would use Gas-Filled Panel insulation throughout the cabinet as well as the doors.

Griffith, B.; Arasteh, D.; Tuerler, D.

1995-01-01T23:59:59.000Z

25

Cost-efficiency analysis in support of the energy conservation standards for refrigerator/freezers  

SciTech Connect (OSTI)

The National Appliance Energy Conservation At (NAECA) of 1987 requires the Department of Energy (DOE) to consider new or amended energy-efficiency standards for refrigerators and freezers along with several other appliances. This paper describes the cost-efficiency analysis of design options carried out in support of the proposed 1998 standards for refrigerator/freezers. These proposed standards are unique in that they have been reached by a consensus of various interested parties including the trade association of refrigerator and freezer manufacturers, environmental groups, state energy offices, and utility companies. In large part, these consensus standards are based on the analysis described in this paper. The analysis shows that, for example, for a 515-liter (18.2-ft{sup 3}) top-mount automatic-defrost refrigerator-freezer, the annual energy consumption can be reduced from 700 kWh/yr (2.52 GJ/yr) to 484 kWh/yr (1.74 GJ/yr) (30.9%) by the use of more efficient fan motors and compressors, improved gaskets, and insulation that is {1/2}-inch (12.7 mm) thicker. The energy use can be further reduced to 422 kWh/yr (1.52 GJ/yr) (39.8%) by employing improved heat exchangers, switching to adaptive defrost, and employing vacuum panel insulation instead of thicker walls and doors.

Hakim, S.H.; Turiel, I. [Lawrence Berkeley National Lab., CA (United States). Energy and Environment Div.

1996-12-31T23:59:59.000Z

26

Field usage and its impact on energy consumption of refrigerator/freezers  

SciTech Connect (OSTI)

This study investigated the effect of door openings and kitchen environment on the energy consumption of nine household refrigerator/freezers (R/Fs) in the field. The factors under consideration include fresh food and freezer door openings, length of door openings, ambient kitchen temperature, and kitchen relative humidity (RH). Average daily energy consumption for the nine units ranged from 1.7 to 5.3 kWh/day. Energy consumption was found to correlate with kitchen temperature and the number of door openings. No dependence on kitchen relative humidity was found. In general, the magnitude of the door opening component of energy consumption was higher for the more efficient units.

Gage, C.L. [Environmental Protection Agency, Research Triangle Park, NC (United States). Air Pollution Prevention and Control Div.

1995-12-31T23:59:59.000Z

27

Simulating effects of multispeed compressors on refrigerator/freezer performance  

SciTech Connect (OSTI)

Simulation analyses suggest that a multispeed compressor could increase steady-state operating efficiency by 4% to 14%. An additional 0.5% to 4% energy savings might be obtained from the reduction in the cycling frequency of the refrigerator. Several aspects of the robustness of the capillary tube-suction line heat exchanger design for the two-speed compressor system were also examined with the simulation model. It was shown that a system optimized for low-speed operation, when operating at the high speed, could have as much capacity as the original base case high-speed system. A relatively simple control strategy was proposed, one that requires measurement of on-cycle time and one or two compartment air temperatures. The effects of varying the speed of the evaporator or condenser fans at both compressor speeds were examined over a range of ambient temperatures. One energy-saving scenario was identified: decreasing the condenser fan speed for refrigerators operating at low ambient temperatures. By affecting the distribution of refrigerant change throughout the system, the decrease in condenser fan speed reduces the superheat in the evaporator and increases the overall UA of the evaporator. The resulting increase in evaporator capacity more than offsets the decrease in condenser UA and the energy use of the refrigerator is decreased.

Woodall, R.J. [International Paper Technology, Mobile, AL (United States); Bullard, C.W. [Univ. of Illinois, Urbana, IL (United States). Air Conditioning and Refrigeration Center

1997-12-31T23:59:59.000Z

28

Evaluation of ozone-friendly hydrofluoropropane-based zeotropic refrigerant mixtures in a Lorenz-Meutzner refrigerator/freezer  

SciTech Connect (OSTI)

The design of the Lorenz-Meutzner refrigerator/freezer has two evaporators (located in the freezer and fresh food compartments), which makes it a leading candidate for use of zeotropic refrigerant mixtures. Zeotropic mixtures can have significant temperature glides during evaporation and condensation. Performance of the zeotropic mixture can be maximized in the LM design by permitting the lower end of the temperature glide to occur in the freezer compartment evaporator and the higher end in the fresh food compartment evaporator. Several hydrofluoropropane-based zeotropes (e.g., R-227 ea/R-245ca) have been shown through steady-state modeling to outperform R-134a by up to 15%. Results from previous testing of this refrigerator/freezer using R-32/R-124 (zeotropic mixture) were published in an ASHRAE paper (Sand et al. 1993). Their results showed performance gains of approximately 3% over R-12. In the study presented in this paper, the Lorenz-Meutzner refrigerator/freezer having two evaporators and two intercoolers was experimentally tested in an environmental chamber according to Association of Home Appliance Manufacturers/Department of Energy (AHAM/DOE) testing standards using several hydrofluoropropane-based zeotropic mixtures. The results are compared to baseline testing with R-134a. The R-245ca/R-134a and R-245ca/R-152a mixtures performed comparably to R-134a. R-245ca/R-270 outperformed all zeotropic mixtures and R-134a by at least 16%. Also, a refrigerant sampling loop is added to determine the running composition of the mixture and its effects on the performance of the refrigerator/freezer.

Baskin, E. [Environmental Protection Agency, Research Triangle Park, NC (United States); Bayoglu, E.S.; Delafield, F.R. [Acurex Environmental Corp., Durham, NC (United States)

1997-12-31T23:59:59.000Z

29

Environmental assessment for proposed energy conservation standards for refrigerators, refrigerator-freezers, and freezers  

SciTech Connect (OSTI)

This Environmental Assessment (EA) on the candidate energy conservation standards for refrigerators, refrigerator-freezers, and freezers was prepared pursuant to the National Environmental Policy Act of 1969 (NEPA), regulations of the Council on Environmental Quality, Title 40, Code of Federal Regulations, Parts 1500 through 1508. The proposed energy conservation standard (Level 1) and the alternative standards are being reviewed in an energy-efficiency standards rulemaking that the Department has undertaken pursuant to the Energy Policy and Conservation Act, as amended by the National Energy Conservation Policy Act and the National Appliance Energy Conservation Act. The EA presents the associated environmental impacts from four energy conservation standards for this type of household appliance. For purposes of this EA, each standard is an alternative action and is compared to what is expected to happen if no new standards for this type of product were finalized, i.e., the no action alternative. Of the four energy conservation standard levels considered, standard level 4 has the highest level of energy efficiency and the largest environmental impact. The proposed action implementing Standard Level 1 would have the least environmental impacts, through emission reductions, of the four alternatives. The description of the standards results from the appliance energy-efficiency analyses conducted for the rulemaking. The presentation of environmental impacts for each of the alternatives appears at Section 3 of the EA.

NONE

1996-01-01T23:59:59.000Z

30

Field test of a high-efficiency, automatic-defrost refrigerator-freezer  

SciTech Connect (OSTI)

Following the successful design, development, and demonstration of a high efficiency refrigerator-freezer prototype, work was done to design and manufacture pre-production units for home usage tests. The purpose of the field test and the associated market evaluation is to confirm the energy saving potential of the high-efficiency design, identify possible design deficiencies or service difficulties, and assess the consumer appeal of the new unit. The first five months of field test data have shown an average 57% decrease in energy consumption when compared to a baseline unit of convention design. This energy savings is larger than predicted by the standard DOE test procedure. No serious design or service problems have been encountered. Consumers have not been adversely affected by the larger cabinet and thicker doors, and responded favorably in an actual retail sales test to initially spending more for an energy-saving refrigerator that will reduce electric usage.

Topping, R.F.; Vineyard, E.A.

1982-01-01T23:59:59.000Z

31

2014-07-10 Issuance: Test Procedures for Refrigerators, Refrigerator-Freezers, and Freezers; Final Rule Correction  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register final rule correction regarding test procedures for refrigerators, refrigerator-freezers, and freezers, as issued by the Deputy Assistant Secretary for Energy Efficiency on July 10, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

32

Evaluation of performance and composition shift of zeotropic mixtures in a Lorenz-Meutzner refrigerator/freezer  

SciTech Connect (OSTI)

Results from previous testing of this refrigerator/freezer using a 750 Btu/h compressor and several zeotropic mixtures revealed a performance enhancement up to 16% above that of hydrofluorocarbon R-134a. In the study presented in this paper, the Lorenz-Meutzner (LM) refrigerator/freezer equipped with a 1060 Btu/h compressor, two evaporators, and two intercoolers was experimentally tested in an environmental chamber according to the Association of Home Appliance Manufacturers/Department of Energy (AHAM/DOE) testing standards using several hydrofluoropropane-based zeotropic mixtures. The results are compared to baseline testing with R-134a and results obtained using the 750 Btu/h compressor. Hydrofluorocarbons R-245ca/R-152a performed comparably to R-134a. R-245ca/hydrocarbon R-270 (cyclopropane C{sub 3}H{sub 6}) outperformed all zeotropic mixtures and R-134a by at least 12.2 {+-} 0.7%. All refrigerants performed better using the larger compressor due to its inherently better efficiency. Refrigerant samples taken during refrigerator/freezer operation revealed substantial composition shifts (e.g., a 30% running composition shift of R-134a in the R-245ca/R-134a mixture). Sand et al. (1993) obtained an approximately 20% energy reduction using steady-state on-cycle energy consumption results; a comparison was made between chlorofluorocarbon R-12 and a hydrofluorocarbon R-32/hydrochlorofluorocarbon R-124 mixture. Lorenz and Meutzner (1975), originators of the Lorenz-Meutzner refrigerator/freezer design, state that the following parameters influence the optimum performance of the design: (1) heat exchanger size, (2) capillary tube length, (3) refrigerant charge, and (4) compressor size. This work investigates three of these parameters--capillary tube length, compressor size, and refrigerant charge.

Baskin, E.; Smith, N.D.; Delafield, F.R.; Tufts, M.W.

1999-07-01T23:59:59.000Z

33

Evaluation of design options for improving the energy efficiency of an environmentally safe domestic refrigerator-freezer  

SciTech Connect (OSTI)

In order to reduce greenhouse emissions from power plants and respond to regulatory actions arising from the National Appliance Energy Conservation Act (NAECA), several design options were investigated for improving the energy efficiency of a conventionally designed, domestic refrigerator-freezer. The options, such as improved cabinet insulation and high-efficiency compressor and fans, were incorporated into a prototype refrigerator-freezer cabinet and refrigeration system to produce a unit that is superior from an environmental viewpoint due to its lower energy consumption and the use of refrigerant HFC-134a as a replacement for CFC-12. Baseline energy performance of the original 1993 production refrigerator-freezer, along with cabinet heat load and compressor calorimeter test results, were extensively documented to provide a firm basis for experimentally measured energy savings. A detailed refrigerator system computer model was used to evaluate the energy savings for several design modifications that, collectively, could achieve a targeted energy consumption of 1.00 kWh/d for a 20 ft{sup 3} (570 l) top-mount, automatic-defrost, refrigerator-freezer. The energy consumption goal represents a 50% reduction in the 1993 NAECA standard for units of this size. Following the modeling simulation, laboratory prototypes were fabricated and tested to experimentally verify the analytical results and aid in improving the model in those areas where discrepancies occurred. While the 1.00 kWh/d goal was not achieved with the modifications, a substantial energy efficiency improvement of 22% (1.41 kWh/d) was demonstrated using near-term technologies. It is noted that each improvement exacts a penalty in terms of increased cost or system complexity/reliability. Further work on this project will analyze cost-effectiveness of the design changes and investigate alternative, more-elaborate, refrigeration system changes to further reduce energy consumption.

Vineyard, E.A.; Sand, J.R. [Oak Ridge National Lab., TN (United States); Bohman, R.H.

1995-03-01T23:59:59.000Z

34

Investigation of design options for improving the energy efficiency of conventionally designed refrigerator-freezers  

SciTech Connect (OSTI)

Several design options for improving the energy efficiency of conventionally-designed, domestic refrigerator freezers (RFs) were incorporated into two 1990 production RF cabinets and refrigeration systems. The baseline performance of the original units and unit components were extensively documented to provide a firm basis for experimentally measured energy savings. A detailed refrigerator system computer model which could simulate cycling behavior was used to evaluate the daily energy use impacts for each modification, and modeled versus experimental results are compared. The model was shown to track measured RF performance improvement sufficiently well that it was used with some confidence to investigate additional options that could not be experimentally investigated. Substantial improvements in RF efficiency were demonstrated with relatively minor changes in system components and refrigeration circuit design. However, each improvement exacts a penalty in terms of increased cost or system complexity/reliability. For RF sizes typically sold in the United States (18-22 ft{sup 3} [510--620 1]), alternative, more-elaborate, refrigeration cycles may be required to achieve the program goal (1.00 Kilowatt-hour per day for a 560 l, top mount RF.

Sand, J.R.; Vineyard, E.A. [Oak Ridge National Lab., TN (United States); Bohman, R.H. [Consulting Engineer, Cedar Rapids, IA (United States)

1993-11-01T23:59:59.000Z

35

EPA's research projects relating to the dual-circuit and Lorenz refrigerator/freezers  

SciTech Connect (OSTI)

The paper discusses EPA research projects relating to the dual-circuit and Lorenz refrigerator/freezers (RFs). EPA is interested in not only phasing out chlorofluorocarbons (CFCs) in RFs, but doing so in a way that will maximize energy efficiency and minimize subsequent impacts on the greenhouse effect. An early decision was made to concentrate on replacing fully halogenated CFCs in RFs during the first year of EPA's research. RFs were chosen because they are small, require small quantities of refrigerants, are relatively easy to modify and test, and are the most energy-consumptive appliances in most U.S. households. In the future, other applications are expected to receive more attention. The first year of EPA's program has concentrated on implementing two alternative configurations of RFs which are believed to have the potential to make RFs more energy efficient: the dual-circuit and the Lorenz RFs. Research has included modeling alternative refrigerants and Non-azeotropic Refrigerant Mixtures (NARMs) in the dual-circuit and Lorenz configurations and experimental testing of modified RFs and refrigeration components in test stands.

Bare, J.C.

1992-01-01T23:59:59.000Z

36

Engineering computer models for refrigerators, freezers, furnaces, water heaters, room and central air conditioners  

SciTech Connect (OSTI)

This User's Guide provides the necessary information for understanding and using a computer model developed for the US Department of Energy which predicts the performance (energy consumption) of household refrigerators, refrigerator-freezers, and freezers. The model is capable of simulating various cabinet configurations (top-mount, bottom-mount, side-by-side, single-door) and refrigeration unit combinations (back-mounted static condenser with single forced convection evaporator, hot wall condenser with cooled wall panels, etc.). The program is comprised of two main subroutines: a cabinet heat-load submodel and a refrigeration unit submodel; they can be used separately for preliminary design analysis or together for performance evaluations. A technical description of the model and information on how to structure input parameters are provided. The user is provided with specific guidance for running the model on a computer. Specific instructions are given in the Appendices for changing and running the model using the operating language compatible with the DOE computer terminal system. Other users will have to modify the procedures in these sections as necessary for different computers.

Not Available

1982-11-01T23:59:59.000Z

37

EPA's research projects relating to the dual-circuit and Lorenz refrigerator/freezers  

SciTech Connect (OSTI)

At a meeting in February 1989, EPA presented to several research universities, national laboratories, and refrigerator/freezer (RF) manufacturers the Agency's desire to replace CFC-12 as a refrigerant in the RF vapor compression cycle and increase RF energy efficiency. EPA recognized that, while eliminating CFCs, energy benefits could be gained by further product development (e.g., improving compressor efficiency or heat transfer surface areas). The largest cycle energy gains, however, were expected to be a result of completely different vapor compression configuration. Two new vapor compression configurations were suggested by the participants - the Lorenz design and the dual-circuit design. A decision was made to construct and test modified RFs as proof that the advanced refrigerants and cycles could achieve energy gains. An RF computer model has been updated and expanded which can model both the Lorenz and dual-circuit RF. Modified RF testing and component testing in test stands is being performed to determine the increased energy performance of these configurations.

Bare, J.C. (Environmental Protection Agency, Research Triangle Park, NC (United States))

1992-01-01T23:59:59.000Z

38

2014-04-10 Issuance: Test Procedures for Refrigerators, Refrigerator-Freezers, and Freezers; Final Rule  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register final rule regarding test procedures for residential refrigerators and freezers, as issued by the Deputy Assistant Secretary for Energy Efficiency on April 10, 2014.

39

Advanced insulations for refrigerator/freezers: The potential for new shell designs incorporating polymer barrier construction  

SciTech Connect (OSTI)

The impending phase-out of chlorofluorocarbons (CFCs) used to expand foam insulation, combined with requirements for increased energy efficiency, make the use of non-CFC-based high performance insulation technologies increasingly attractive. The majority of current efforts are directed at using advanced insulations in the form of thin, flat low-conductivity gas-filled or evacuated orthogonal panels, which we refer to as Advanced Insulation Panels (AIPs). AIPs can be used in composite with blown polymer foams to improve insulation performance in refrigerator/freezers (R/Fs) of conventional design and manufacture. This AIP/foam composite approach is appealing because it appears to be a feasible, near-term method for incorporating advanced insulations into R/Fs without substantial redesign or retooling. However, the requirements for adequate flow of foam during the foam-in-place operation impose limitations on the allowable thickness and coverage area of AIPs. This report examines design alternatives which may offer a greater increase in overall thermal resistance than is possible with the use of AIP/foam composites in current R/F design. These design alternatives generally involve a basic redesign of the R/F taking into account the unique requirements of advanced insulations and the importance of minimizing thermal bridging with high thermal resistance insulations. The focus here is on R/F doors because they are relatively simple and independent R/F components and are therefore good candidates for development of alterative designs. R/F doors have significant thermal bridging problems due to the steel outer shell construction. A three dimensional finite difference computer modeling exercise of a R/F door geometry was used to compare the overall levels of thermal resistance (R-value) for various design configurations.

Griffith, B.T.; Arasteh, D.

1992-11-01T23:59:59.000Z

40

Simulation results of single refrigerants for use in a dual-circuit refrigerator/freezer  

SciTech Connect (OSTI)

Dual-circuit RFs have been shown to have a theoretical advantage over single-evaporator RFs if the compressor efficiencies of the separate loops are equivalent to the compressor efficiency of the combined system. Single refrigerants were analyzed to determine the optimum pure refrigerant in each of the two separate freezer and fresh food loops. R-152a and R-142b were determined to be the optimum single refrigerants in the dual-circuit system. With the assumptions made, theoretical energy savings of up to 23% of compressor power are possible.

Bare, J.C. (Environmental Protection Agency, Research Triangle Park, NC (United States))

1992-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

The alternative refrigerant dilemma for refrigerator-freezers: Truth or consequences  

SciTech Connect (OSTI)

In an effort to select a refrigerant that has minimal impact on energy consumption and the environment, a screening analysis of potential refrigerants was performed that resulted in the selection of six candidates. The screening results show that R-134a, R-134, R-152a, R-134a/R-152a, R-22/R-152a/R-124, and R-134a/R-152a/R-124 are the most promising refrigerants based on the following criteria: ozone depletion potential, greenhouse warming potential, coefficient of performance, and safety. Energy consumption tests were performed for the three pure refrigerants in accordance with the Association of Home Appliance Manufacturers standard for household refrigerators and household freezers. The results indicate an increased energy consumption of 6.8%, 7.3%, and 7.3%, respectively for R-134, R-152a, and R-134a in the most efficient oil. However, when the effects of compressor efficiency are taken into account, the normalized energy consumption results in an increase of only 2.7% for R-152a and 5.5% for both R-134a and R-134. 14 refs., 5 tabs.

Vineyard, E.A.

1991-01-01T23:59:59.000Z

42

Development of a high-efficiency, automatic-defrosting refrigerator-freezer. Phase II. Field test. Volume III. Executive summary and task reports  

SciTech Connect (OSTI)

The second phase of the development of a high-efficiency, automatic-defrosting, refrigerator-freezer is described. Following the successful completion of Phase I (design, construction, and laboratory testing of a 16 ft/sup 3/ high efficiency refrigerator-freezer prototype), Phase II was initiated to evaluate sales potential and in-home performance as a necessary step in creating a product that was both manufacturable and marketable. Twenty-five pilot production 18 ft/sup 3/ units using prototype tooling were produced on the assembly line to confirm the feasibility of full-scale production. These units were then used in a market and field test program in which consumer appeal and in-home performance were assessed. The market evaluation confirmed that refrigerators incorporating high-efficiency features at added cost are saleable and that large capacity, automatic-defrosting, refrigerator-freezers will continue to capture a large portion of the market in the years ahead, The field test confirmed the in-home energy saving potential of a high efficiency, automatic-defrosting refrigerator-frezer utilizing advanced design features such as optimized, thick-wall, foam an average energy savings of 60% compared to a baseline unit of conventional design.

Topping, R.F.

1982-12-01T23:59:59.000Z

43

Potential Impact of Adopting Maximum Technologies as Minimum Efficiency Performance Standards in the U.S. Residential Sector  

E-Print Network [OSTI]

Refrigerators, Refrigerator-Freezers, Freezers PreliminaryRefrigerators, Refrigerator-Freezers, Freezers Pre-NOPRlighting, television, refrigerator-freezers, central air

Letschert, Virginie

2010-01-01T23:59:59.000Z

44

Residential Energy Star Appliance Rebate Program  

Broader source: Energy.gov [DOE]

Energy Trust of Oregon offers rebates for Energy Star refrigerators, freezers and clothes washers to Oregon residential electric service customers of Portland General Electric (PGE) and Pacific...

45

East Central Energy- Residential Energy Efficiency Rebate Program  

Broader source: Energy.gov [DOE]

East Central Energy (ECE) provides rebates for residential customers to purchase energy efficient equipment. Rebates are offered for recycled refrigerators/freezers, central air conditioning units,...

46

Clark Public Utilities- Residential Energy Efficiency Rebate Program  

Broader source: Energy.gov [DOE]

Clark Public Utilities offers several energy incentives for residential customers to increase the energy efficiency of their homes. Rebates are offered for refrigerators, freezers, clothes washers,...

47

McMinnville Water and Light- Residential Energy Efficiency Rebate Program  

Broader source: Energy.gov [DOE]

McMinnville Water and Light (MWL) offers rebates on energy efficient homes, appliances and equipment to their residential customers. Rebates are valid on refrigerators, freezers, clothes washer,...

48

Experimental results of a household automatic icemaker in a refrigerator/freezer  

SciTech Connect (OSTI)

This paper describes the performance test results of an automatic icemaker refrigerator under various modes of icemaker operation. The tests were conducted on a 20-ft{sup 3} (0.566-m{sup 3}) household refrigerator that had a single forced convection evaporator and was charged with R-12. The focus of the research was to ascertain the effect of icemaker operation on the refrigerator`s daily energy consumption. Thus, three different types of tests were conducted, depending upon the icemaker`s operating mode. In the first test type, the baseline, the automatic icemaker was turned off and no ice was made. In the second test type, the ice-making mode (test A), the icemaker was turned on and ice was continuously made. Compared to the baseline, additional power was intermittently consumed by a mold heater that melts the ice cubes` interface with the tray, a solenoid valve that supplies water to the icemaker tray, and a motor that rotates the ejector blades to press the crescent-shaped ice cubes out of the mold and unload them into an ice bin. In the third test type, the failure mode (test B), the water supply was manually disconnected but the icemaker was left turned on. Even though no ice was made, additional power was still consumed by the mold heater, the solenoid valve, and the motorized ejector. In tests A and B, the energy consumed by the icemaker`s components increases the cooling load, which raises the compressor power consumption. The present study shows that at the AHAM-specified test conditions, uninterrupted icemaking increased the daily energy consumption by 22.5% to 27.2%.

Haider, I.; Feng, H.; Radermacher, R. [Univ. of Maryland, College Park, MD (United States). Center for Environmental Energy Engineering

1996-12-31T23:59:59.000Z

49

Magnetocaloric Refrigerator Freezer  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department of Energy Low-Temperature CombustionGlassMackleMagnetically

50

Technical support document: Energy efficiency standards for consumer products: Refrigerators, refrigerator-freezers, and freezers including draft environmental assessment, regulatory impact analysis  

SciTech Connect (OSTI)

The Energy Policy and Conservation Act (P.L. 94-163), as amended by the National Appliance Energy Conservation Act of 1987 (P.L. 100-12) and by the National Appliance Energy Conservation Amendments of 1988 (P.L. 100-357), and by the Energy Policy Act of 1992 (P.L. 102-486), provides energy conservation standards for 12 of the 13 types of consumer products` covered by the Act, and authorizes the Secretary of Energy to prescribe amended or new energy standards for each type (or class) of covered product. The assessment of the proposed standards for refrigerators, refrigerator-freezers, and freezers presented in this document is designed to evaluate their economic impacts according to the criteria in the Act. It includes an engineering analysis of the cost and performance of design options to improve the efficiency of the products; forecasts of the number and average efficiency of products sold, the amount of energy the products will consume, and their prices and operating expenses; a determination of change in investment, revenues, and costs to manufacturers of the products; a calculation of the costs and benefits to consumers, electric utilities, and the nation as a whole; and an assessment of the environmental impacts of the proposed standards.

NONE

1995-07-01T23:59:59.000Z

51

Catalog of DC Appliances and Power Systems  

E-Print Network [OSTI]

current residential refrigerators and freezers rulemaking,Refrigerator/Freezers. .Refrigerator, Refrigerator-Freezer, and Freezers Rulemaking,

Garbesi, Karina

2012-01-01T23:59:59.000Z

52

Environmental assessment for proposed energy conservation standards for two types of consumer products; refrigerators, refrigerator-freezers, and freezers; small gas furnaces; and a proposed No standard standard for television sets  

SciTech Connect (OSTI)

This environmental assessment (EA) evaluates the environmental impacts resulting from new or amended energy-efficiency standard for refrigerators, refrigerator-freezers, freezers, small gas furnaces, and television sets as mandated by the National Appliance Energy Conservation Act of 1987. A complete description of the Engineering and Economic Analysis of the proposed standards may be found elsewhere in the Technical Support Document (TSD). Four of the 14 scenarios for product design changes described in the Engineering Analysis of the TSD are chosen for environmental assessment based on their relative importance as design measures. Values for energy savings that result from product design changes are also taken from the TSD. The two main environmental concerns addressed are emissions from fossil fuel-fired electricity generation and the chlorofluorcarbons used in the production of rigid insulation foam. Each of the 12 design options for refrigerators and freezers result in decreased electricity use and and, therefore, reduced power plant emissions. Design changes that call for additional rigid foam insulation per appliance are of interest because they affect chlorofluorocarbon consumption. There is strong evidence that chlorofluorocarbons migrate to the stratosphere, break down, and catalyze the destruction of stratospheric ozone.

Not Available

1988-01-01T23:59:59.000Z

53

Analysis of Michigan's demand-side electricity resources in the residential sector: Volume 3, End-use studies: Revised final report  

SciTech Connect (OSTI)

This volume of the ''Analysis of Michigan's Demand-Side Electricity Resources in the Residential Sector'' contains end-use studies on various household appliances including: refrigerators, freezers, lighting systems, water heaters, air conditioners, space heaters, and heat pumps. (JEF)

Krause, F.; Brown, J.; Connell, D.; DuPont, P.; Greely, K.; Meal, M.; Meier, A.; Mills, E.; Nordman, B.

1988-04-01T23:59:59.000Z

54

DOE EPCA Commercial Refrigeration Standards - EERE-2010-BT-STD...  

Broader source: Energy.gov (indexed) [DOE]

Final Rule 2014-04-10 Issuance: Test Procedures for Commercial Refrigeration Equipment; Final Rule Refrigerators and Refrigerator-Freezers (Appendix A1 after May 2, 2011)...

55

California DREAMing: the design of residential demand responsive technology with people in mind  

E-Print Network [OSTI]

standards on refrigerators and freezers, room and centralexample, while refrigerators and freezers contribute to peakelectric lights refrigerator/freezer plasma screen

Peffer, Therese E.

2009-01-01T23:59:59.000Z

56

Energy Data Sourcebook for the U.S. Residential Sector  

E-Print Network [OSTI]

The historical factors for refrigerators and freezers arehistorical factors are used are gas heating, room and central air- conditioning, electric and gas water-heating, refrigerators, freezers,

Wenzel, T.P.

2010-01-01T23:59:59.000Z

57

Refrigerators and Refrigerator-Freezers (Appendix A1 after May...  

Energy Savers [EERE]

templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE...

58

DOE Opens Three Investigations into Alleged Refrigerator Efficiency...  

Broader source: Energy.gov (indexed) [DOE]

The Department of Energy has issued one subpoena and two data requests to three companies in response to allegations that the companies are selling refrigerator-freezers that...

59

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

SciTech Connect (OSTI)

Amazon Mechanical Turk was used, for the first time, to collect statistically representative survey data from U.S. households on the presence, number, type and usage of refrigerators, freezers, and various “miscellaneous” refrigeration products (wine/beverage coolers, residential icemakers and non-vapor compression refrigerators and freezers), along with household and demographic information. Such products have been poorly studied to date, with almost no information available about shipments, stocks, capacities, energy use, etc. A total of 9,981 clean survey responses were obtained from five distinct surveys deployed in 2012. General refrigeration product survey responses were weighted to demographics in the U.S. Energy Information Administration’s Residential Energy Consumption Survey 2009 dataset. Miscellaneous refrigeration product survey responses were weighted according to demographics of product ownership found in the general refrigeration product surveys. Model number matching for a portion of miscellaneous refrigeration product responses allowed validation of refrigeration product characteristics, which enabled more accurate estimates of the penetrations of these products in U.S. households. We estimated that there were 12.3±1.0 million wine/beverage coolers, 5.5(–3.5,+3.2) million residential icemakers and 4.4(–2.7,+2.3) million non-vapor compression refrigerators in U.S. households in 2012. (All numerical results are expressed with ranges indicating the 95% confidence interval.) No evidence was found for the existence of non-vapor compression freezers. Moreover, we found that 15% of wine/beverage coolers used vapor compression cooling technology, while 85% used thermoelectric cooling technology, with the vast majority of thermoelectric units having capacities of less than 30 wine bottles (approximately 3.5 cubic feet). No evidence was found for the existence of wine/beverage coolers with absorption cooling technology. Additionally, we estimated that there were 3.6±1.0 million hybrid refrigerator-wine/beverage coolers and 0.9±0.5 million hybrid freezer-wine/beverage coolers in U.S. households. We also obtained estimates of miscellaneous refrigeration product capacities, lifetimes, purchase and installation costs, repair frequencies and costs, and maintenance costs. For wine/beverage coolers, we also obtained information on the penetration of built-in units, AC/DC operating capability, the use of internal lights, and distributions of door opening frequencies. This information is essential to develop detailed estimates of national energy usage and life-cycle costs, and would be helpful in obtaining information on other plug-load appliances. Additional information not highlighted in the main report was presented in Appendices.

Greenblatt, Jeffery B.; Young, Scott J.; Yang, Hung-Chia; Long, Timothy; Beraki, Bereket; Price, Sarah K.; Pratt, Stacy; Willem, Henry; Desroches, Louis-Benoit

2013-11-14T23:59:59.000Z

60

Adapted from FDA refrigerator and freezer guidelines: http://www.fda.gov/downloads/Food/ResourcesForYou/HealthEducators/UCM109315.pdf Have you ever wondered how long you should keep things in the refrigerator or freezer? If so, then the chart below can he  

E-Print Network [OSTI]

Adapted from FDA refrigerator and freezer guidelines: http://www.fda.gov/downloads/Food/ResourcesForYou/HealthEducators/UCM109315.pdf Have you ever wondered how long you should keep things in the refrigerator or freezer? If so to preserve quality. Refrigerator & Freezer Storage Chart Product Refrigerator Freezer Product Refrigerator

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

SYMPOSIUM PAPER TC7.1 -DOMESTIC REFRIGERATORS AND FOOD FREEZERS  

E-Print Network [OSTI]

#12;SYMPOSIUM PAPER FOR TC7.1 - DOMESTIC REFRIGERATORS AND FOOD FREEZERS THE ENGINEERING AND MANUFACTURE OF A HIGH EFFICIENCY, AUTOMATIC DEFROSTING REFRIGERATOR-FREEZER by Raymond H. Bohman, P.E. Robert REFRIGERATOR - FREEZER 1. INTRODUCTION This paper describes the engineering effort and method of manufacture

Oak Ridge National Laboratory

62

Ex Parte Communication_Kitable Refrigerator/Freezer Guidance | Department  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power SystemsResources DOEElectricalonJusticeEnergy Efficiency Program forParteSeptemberof

63

Refrigerator-Freezer Appendix A1 | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalancedDepartment ofColumbusReport #Study | DepartmentEvaluations |

64

Refrigerator-Freezers (multiple defrost waiver) | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalancedDepartment ofColumbusReport #Study | DepartmentEvaluations |Freezers

65

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 through 2012  

E-Print Network [OSTI]

Refrigerator-Freezers .Refrigerators and Refrigerator-Freezers NAECA 1987 Freezers2005 Refrigerators, Refrigerator-Freezers and Freezers 2010,

Meyers, Stephen

2013-01-01T23:59:59.000Z

66

Residential Refrigerator Recycling Ninth Year Retention Study  

E-Print Network [OSTI]

Residential Refrigerator Recycling Ninth Year Retention Study Study ID Nos. 546B, 563 Prepared RECYCLING PROGRAMS Study ID Nos. 546B and 563 Prepared for Southern California Edison Rosemead, California

67

Defrost Temperature Termination in Supermarket Refrigeration Systems  

SciTech Connect (OSTI)

The objective of this project was to determine the potential energy savings associated with implementing demand defrost strategies to defrost supermarket refrigerated display case evaporators, as compared to the widely accepted current practice of controlling display case defrost cycles with a preset timer. The defrost heater energy use of several representative display case types was evaluated. In addition, demand defrost strategies for refrigerated display cases as well as those used in residential refrigerator/freezers were evaluated. Furthermore, it is anticipated that future work will include identifying a preferred defrost strategy, with input from Retail Energy Alliance members. Based on this strategy, a demand defrost system will be designed which is suitable for supermarket refrigerated display cases. Limited field testing of the preferred defrost strategy will be performed in a supermarket environment.

Fricke, Brian A [ORNL; Sharma, Vishaldeep [ORNL

2011-11-01T23:59:59.000Z

68

Requirements for Determining Refrigerant Charge Residential Air Conditioning Measures  

E-Print Network [OSTI]

Requirements for Determining Refrigerant Charge Residential Air Conditioning Measures Improved Refrigerant Charge Purpose Component packages require in some climate zones that split system air refrigerant charge. For the performance method, the proposed design is modeled with less efficiency

69

Electricity savings from residential appliance standards in Sweden  

SciTech Connect (OSTI)

This paper discusses the energy savings that could be obtained in Sweden by instituting specific standards for five appliances: Refrigerators, freezers, dishwashers, clothes washers, and clothes dryers. At the present time, Sweden has no minimum energy efficiency standards for residential appliances. This paper discusses the energy savings that could be obtained by instituting specific standards for five product types (refrigerators, freezers, dishwashers, clothes washers, and dryers) starting in 1995. A methodology similar to that used in analyses for the European Community was employed in this study. In the Swedish study, we used appliance test data developed by the Swedish consumer agency, Konsument Verket, to estimate new unit energy consumption for each product type. Shipments, saturations, energy use, and demographic data were input to a spreadsheet model that sums energy consumption for each product type over the period 1990--2010. Both a base case and a standards case scenario are simulated for each of the five appliance types. It was found that electricity use for these five products can be reduced by 12% over the time period from 1990--2010. Most of the energy savings come from instituting efficiency standards for refrigerators and freezers. For each product class type, the impact on manufacturer offerings is discussed. For example, for simple refrigerators, eleven 1990 models meet the 1995 standard and six models meet the 2000 standard out of a total of 63 models.

Turiel, I. [Lawrence Berkeley Lab., CA (United States); Lebot, B. [Agence Francaise pour la Maitrise de l`Energie, 75 - Paris (France)

1993-04-01T23:59:59.000Z

70

Energy use of US residential refrigerators and freezers: function derivation based on household and climate characteristics  

E-Print Network [OSTI]

residential refrigerators and freezers: function derivationsecond most-used) refrigerators, and freezers, and residualfor more efficient refrigerators and freezers, as well as

Greenblatt, Jeffery

2013-01-01T23:59:59.000Z

71

Refrigerators and Refrigerator-Freezers (Appendix A1 after May 2, 2011) |  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalancedDepartment ofColumbusReport #Study | DepartmentEvaluations

72

Evaluation of Local Enforcement of Energy Efficiency Standards and Labeling Program in China  

E-Print Network [OSTI]

of 54 product models of refrigerators, freezers and room airfor household refrigerators/ freezers and room air

Zheng, Nina

2013-01-01T23:59:59.000Z

73

Environmental Stewardship: How Semiconductor Suppliers Help to Meet Energy-Efficiency Regulations and Voluntary Specifications in China  

E-Print Network [OSTI]

Standards Domestic refrigerators/freezers* Room airLabeling Domestic refrigerators/freezers* Room air

Aizhen, Li; Fanara, Andrew; Fridley, David; Merriman, Louise; Ju, Jeff

2008-01-01T23:59:59.000Z

74

Superinsulation in refrigerators and freezers  

SciTech Connect (OSTI)

The results presented here were obtained during Phase 4 of the first CRADA, which had the specific objective of determining the lifetime of superinsulations when installed in simulated refrigerator doors. The second CRADA was established to evaluate and test design concepts proposed to significantly reduce energy consumption in a refrigerator-freezer that is representative of approximately 60% of the US market. The stated goal of this CRADA is to demonstrate advanced technologies which reduce, by 50%, the 1993 National Appliance Energy Conservation Act (NAECA) standard energy consumption for a 20 ft{sup 3} (570 L) top-mount, automatic-defrost, refrigerator-freezer. For a unit this size, the goal translates to an energy consumption of 1.003 kWh/d. The general objective of the research is to facilitate the introduction of efficient appliances by demonstrating design changes that can be effectively incorporated into new products. In previous work on this project, a Phase 1 prototype refrigerator-freezer achieved an energy consumption of 1.413 kWh/d [Vineyard, et al., 1995]. Following discussions with an advisory group comprised of all the major refrigerator-freezer manufacturers, several options were considered for the Phase 2 effort, one of which was cabinet heat load reductions.

Vineyard, E.; Stovall, T.K.; Wilkes, K.E.; Childs, K.W.

1998-02-01T23:59:59.000Z

75

DOE/AHAM advanced refrigerator technology development project  

SciTech Connect (OSTI)

As part of the effort to improve residential energy efficiency and reduce greenhouse emissions from power plants, several design options were investigated for improving the energy efficiency of a conventionally designed domestic refrigerator-freezer. The program goal was to reduce the energy consumption of a 20-ft{sup 3} (570-L) top-mount refrigerator-freeze to 1.00 kWh/d, a 50% reduction from the 1993 National Appliance Energy Conservation Act (NAECA) standard. The options--such as improved cabinet and door insulation, a high-efficiency compressor, a low-wattage fan, a large counterflow evaporator, and adaptive defrost control--were incorporated into prototype refrigerator-freezer cabinets and refrigeration systems. The refrigerant HFC-134a was used as a replacement for CFC-12. The baseline energy performance of the production refrigerator-freezers, along with cabinet heat load and compressor calorimeter test results, were extensively documented to provide a firm basis for experimentally measured energy savings. The project consisted of three main phases: (1) an evaluation of energy-efficient design options using computer simulation models and experimental testing, (2) design and testing of an initial prototype unit, and (3) energy and economic analyses of a final prototype. The final prototype achieved an energy consumption level of 0.93 kWh/d--an improvement of 45% over the baseline unit and 54% over the 1993 NAECA standard for 20-fg{sup 3} (570-L) units. The manufacturer`s cost for those improvements was estimated at $134; assuming that cost is doubled for the consumer, it would take about 11.4 years to pay for the design changes. Since the payback period was thought to be unfeasible, a second, more cost-effective design was also tested. Its energy consumption level was 1.16 kWh/d, a 42% energy savings, at a manufacturer`s cost increase of $53. Again assuming a 100% markup, the payback for this unit would be 6.6 years.

Vineyard, E.A.; Sand, J.R.; Rice, C.K.; Linkous, R.L.; Hardin, C.V.; Bohman, R.H.

1997-03-01T23:59:59.000Z

76

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2010  

E-Print Network [OSTI]

Refrigerators and Refrigerator-Freezers NAECA 1987 Freezers2005 Refrigerators, Refrigerator-Freezers and Freezers 2010,in this case refrigerator-freezers. The average new

Meyers, Stephen

2013-01-01T23:59:59.000Z

77

International Review of the Development and Implementation of Energy Efficiency Standards and Labeling Programs  

E-Print Network [OSTI]

energy labeling for refrigerators and freezers and nationalhousehold electric refrigerators, freezers and combinationfor Refrigerators, Refrigerator-Freezers and Freezers. ”

Zhou, Nan

2013-01-01T23:59:59.000Z

78

Status of China's Energy Efficiency Standards and Labels for Appliances and International Collaboration  

E-Print Network [OSTI]

testing in 2006 for refrigerators, freezers and room air-three products (refrigerators, freezers, air-conditionersStandards Domestic refrigerators/freezers* Room air

Zhou, Nan

2010-01-01T23:59:59.000Z

79

Impacts of China's Current Appliance Standards and Labeling Program to 2020  

E-Print Network [OSTI]

Standards Domestic refrigerators/freezers* Room airLabeling Domestic refrigerators/freezers* Room air3-star compartment Refrigerator/Freezer Chest frozen food

Fridley, David; Aden, Nathaniel; Zhou, Nan; Lin, Jiang

2007-01-01T23:59:59.000Z

80

Compliance and Verification of Standards and Labelling Programs in China: Lessons Learned  

E-Print Network [OSTI]

for household refrigerators/ freezers and room airZhou et al 2008] Refrigerators Freezers Air conditionersZhou et al 2008] Refrigerators Freezers Air conditioners

Saheb, Yamina

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Compliance and Verification of Standards and Labeling Programs in China: Lessons Learned  

E-Print Network [OSTI]

for household refrigerators/ freezers and room airZhou et al 2008] Refrigerators Freezers Air conditionersZhou et al 2008] Refrigerators Freezers Air conditioners

Saheb, Yamina

2011-01-01T23:59:59.000Z

82

Alternative refrigerants and refrigeration cycles for domestic refrigerators  

SciTech Connect (OSTI)

This project initially focused on using nonazeotropic refrigerant mixtures (NARMs) in a two-evaporator refrigerator-freezer design using two stages of liquid refrigerant subcooling. This concept was proposed and tested in 1975. The work suggested that the concept was 20% more efficient than the conventional one-evaporator refrigerator-freezer (RF) design. After considerable planning and system modeling based on using a NARM in a Lorenz-Meutzner (L-M) RF, the program scope was broadened to include investigation of a ``dual-loop`` concept where energy savings result from exploiting the less stringent operating conditions needed to satisfy cooling, of the fresh food section. A steady-state computer model (CYCLE-Z) capable of simulating conventional, dual loop, and L-M refrigeration cycles was developed. This model was used to rank the performance of 20 ozone-safe NARMs in the L-M refrigeration cycle while key system parameters were systematically varied. The results indicated that the steady-state efficiency of the L-M design was up to 25% greater than that of a conventional cycle. This model was also used to calculate the performance of other pure refrigerants relative to that of dichlorodifluoromethane, R-12, in conventional and dual-loop RF designs. Projected efficiency gains for these cycles were more modest, ranging from 0 to 10%. Individual compressor calorimeter tests of nine combinations of evaporator and condenser temperatures usually used to map RF compressor performance were carried out with R-12 and two candidate L-M NARMs in several compressors. Several models of a commercially produced two-evaporator RF were obtained as test units. Two dual-loop RF designs were built and tested as part of this project.

Sand, J.R.; Rice, C.L.; Vineyard, E.A.

1992-12-01T23:59:59.000Z

83

Estimate of Cost-Effective Potential for Minimum Efficiency Performance Standards in 13 Major World Economies Energy Savings, Environmental and Financial Impacts  

E-Print Network [OSTI]

Fans Lighting Refrigerators and Freezers Space Heating Our2011b. Refrigerator, Refrigerator-Freezer and Freezers Final2011c. Refrigerator, Refrigerator-Freezer and Freezers Final

Letschert, Virginie E.

2013-01-01T23:59:59.000Z

84

Conservation Division regiulations for appliance-efficiency standards relating to refrigerators and freezers, room air conditioners, central air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances  

SciTech Connect (OSTI)

The text of the appliance efficiency standards for certain types of new appliances sold in California is presented. Specifications and test methods to identify complying refrigerators, freezers, air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances are covered.

Not Available

1981-12-16T23:59:59.000Z

85

Hisense USA: Order (2010-CE-1211)  

Broader source: Energy.gov [DOE]

DOE issued an Order after entering into a Compromise Agreement with Hisense USA Corp. after finding Hisense USA had failed to certify that certain models of residential refrigerators, refrigerator-freezers, and freezers comply with the applicable energy conservation standards.

86

International Comparison of Energy Efficiency Awards for Appliance Manufacturers and Retailers  

E-Print Network [OSTI]

dehumidifiers, refrigerators and freezers, room airAutomatic Commercial Ice Makers Refrigerators, Freezers,and Refrigerator?Freezers Refrigerated Beverage Vending

Zhou, Nan

2014-01-01T23:59:59.000Z

87

ISSUANCE 2015-02-03: Energy Efficiency Program for Residential Products: Energy Conservation Standards for Miscellaneous Refrigeration Products, Reopening of Public Comment Period  

Broader source: Energy.gov [DOE]

Energy Efficiency Program for Residential Products: Energy Conservation Standards for Miscellaneous Refrigeration Products, Reopening of Public Comment Period

88

Analysis of Minimum Efficiency Standards and Rebate Incentive Programs for Domestic Refrigerators in the Pacific Northwest.  

SciTech Connect (OSTI)

Refrigerator-freezers (R/Fs) and freezers (FRs) account for 16% of the electricity consumed in the residential sector of the Bonneville Power Administration (BPA) forecast region (Oregon, Washington, Idaho and Western Montana). After space and water heating, R/Fs are the largest residential electrical end-use. There is great potential for reducing electricity consumption in a cost-effective manner through the purchase and use of more energy-efficient R/Fs and FRs. For example, if every household in the BPA region had the best R/F model now mass-produced, the electricity savings would be about 5 billion kWh/yr, approximately the power supplied annually by 1000 MW of nuclear or coal-fired generating capacity. The Northwest Power Planning Council (NPPC) and BPA recognize the savings potential from efficient R/Fs and FRs as well as the barriers to their use. In the 1983 regional power plan, the Council directed BPA to develop and implement incentive and promotion programs for efficient appliances. The NPPC also called for the evaluation of minimum efficiency standards for appliances sold in the region. In response to this directive, the Office of Conservation in BPA funded an evaluation of both rebate incentive programs and minimum efficiency standards for R/Fs and FRs. The results are presented in this report.

Geller, Howard S.

1985-11-01T23:59:59.000Z

89

Evaluation of advanced technologies for residential appliances and residential and commercial lighting  

SciTech Connect (OSTI)

Section 127 of the Energy Policy Act requires that the Department of Energy (DOE) prepare a report to Congress on the potential for the development and commercialization of appliances that substantially exceed the present federal or state efficiency standards. Candidate high-efficiency appliances must meet several criteria including: the potential exists for substantial improvement (beyond the minimum established in law) of the appliance`s energy efficiency; electric, water, or gas utilities are prepared to support and promote the commercialization of such appliances; manufacturers are unlikely to undertake development and commercialization of such appliances on their own, or development and production would be substantially accelerated by support to manufacturers. This report describes options to improve the efficiency of residential appliances, including water heaters, clothes washers and dryers, refrigerator/freezers, dishwashers, space heating and cooling devices, as well as residential and commercial lighting products. Data from this report (particularly Appendix 1)were used to prepare the report to Congress mentioned previously. For the residential sector, national energy savings are calculated using the LBL Residential Energy Model. This model projects the number of households and appliance saturations over time. First, end-use consumption is calculated for a base case where models that only meet the standard replace existing models as these reach the end of their lifetime. Second, models with efficiencies equal to the technology under consideration replace existing models that reach the end of their lifetime. For the commercial sector, the COMMEND model was utilized to project national energy savings from new technologies. In this report, energy savings are shown for the period 1988 to 2015.

Turiel, I.; Atkinson, B.; Boghosian, S.; Chan, P.; Jennings, J.; Lutz, J.; McMahon, J.; Rosenquist, G.

1995-01-01T23:59:59.000Z

90

White Paper on Energy Efficiency Status of Energy-Using Products in China (2011)  

E-Print Network [OSTI]

Variable speed AC Gas water heaters Refrigerators Freezer-refrigerators Freezers CC?4500 CC?7100 CC?14000 CC?4500 CC?televisions, refrigerators (with freezer), cellular phones,

Zhou, Nan

2013-01-01T23:59:59.000Z

91

An experimental study of waste heat recovery from a residential refrigerator  

SciTech Connect (OSTI)

This paper describes the design, construction, and testing of an integrated heat recovery system which has been designed both to enhance the performance of a residential refrigerator and simultaneously to provide preheated water for an electric hot water heater. A commercial, indirect-heated hot water tank was retrofitted with suitable tubing to permit it to serve as a water cooled condenser for a residential refrigerator. This condenser operates in parallel with the air-cooled condenser tubing of the refrigerator so that either one or the other is active when the refrigerator is running. The refrigerator was housed in a controlled-environment chamber, and it was instrumented so that its performance could be monitored carefully in conjunction with the water pre-heating system. The system has been tested under a variety of hot water usage protocols, and the resulting data set has provided significantly insight into issues associated with commercial implementation of the concept. For the case of no water usage, the system was able to provide a 35 C temperature rise in the storage tank after about 100 hours of continuous operation, with no detectable deterioration of the refrigerator performance. Preliminary tests with simulations of high water usage, low water usage, and family water usage indicate a possible 18--20% energy savings for hot water over a long period of operation. Although the economic viability for such a system in a residential environment would appear to be sub-marginal, the potential for such a system associated with commercial-scale refrigeration clearly warrants further study, particularly for climates for which air conditioning heat rejection is highly seasonal.

Clark, R.A.; Smith, R.N.; Jensen, M.K. [Rensselaer Polytechnic Inst., Troy, NY (United States)

1996-12-31T23:59:59.000Z

92

Analysis of Minimum Efficiency Standards and Rebate Incentive Programs for Domestic Refrigerators in the Pacific Northwest, Executive Summary.  

SciTech Connect (OSTI)

Refrigerator-freezers (R/Fs) and freezers (FRs) account for 16% of the electricity consumed in the residential sector of the Bonneville Power Administration (BPA) forecast region (Oregon, Washington, Idaho and Western Montana). After space and water heating, R/Fs are the largest residential electrical end-use. The Northwest Power Planning Council (NPPC) and BPA recognize the savings potential from efficient R/Fs and FRs as well as the barriers to their use. In the 1983 regional power plan, the Council directed BPA to develop and implement incentive and promotion programs for efficient appliances. The NPPC also called for the evaluation of minimum efficiency standards for appliances sold in the region. In response to this directive, the Office of Conservation in BPA funded an evaluation of both rebate incentive programs and minimum efficiency standards for R/Fs and FRs. The results are presented in this report. The energy savings potential and economic feasibility of rebate programs and efficiency standards are the primary issues considered.

Geller, Howard S.

1986-01-01T23:59:59.000Z

93

The effect of new priorities and new materials on residential refrigerator design  

SciTech Connect (OSTI)

Increasing energy-efficiency requirements, combined with environmental considerations, have resulted in designs for domestic refrigerators that incorporate new thermal insulating materials. The first series of tests of these materials have been sufficiently promising that incorporation of vacuum insulations if likely within the next several years. Initial designs will probably use a combination of vacuum insulations and foam; in future designs, major parts consolidation will be possible using structural and other characteristics of the new panel assemblies. Given optimization of the refrigerator thermal envelope according to life-cycle costs, energy use by refrigerators could be greatly reduced; refrigerators could lose their significance as a major component in residential energy-use. Possible forms in which these new materials will be used are discussed, including alternatives for composite assembly and requirements for reliability and durability.

Benson, D.K.; Potter, T.F.

1992-08-01T23:59:59.000Z

94

Fagor America: Proposed Penalty (2013-CEW-19001)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that Fagor America, Inc. failed to certify a variety of residential refrigerator-freezers and dishwashers as compliant with the applicable energy and water conservation standards.

95

Fagor America: Order (2013-CEW-19001)  

Broader source: Energy.gov [DOE]

DOE ordered Fagor America, Inc. to pay a $13,000 civil penalty after finding Fagor America had failed to certify that certain models of residential refrigerator-freezers and dishwashers comply with the applicable energy and water conservation standards.

96

California Appliance Efficiency Regulations for Manufacturers  

E-Print Network [OSTI]

· Externalpowersupplies · Refrigerators,refrigerator-freezers, andfreezers · Televisions,andconsumeraudio and video

97

Residential applliance data, assumptions and methodology for end-use forecasting with EPRI-REEPS 2.1  

SciTech Connect (OSTI)

This report details the data, assumptions and methodology for end-use forecasting of appliance energy use in the US residential sector. Our analysis uses the modeling framework provided by the Appliance Model in the Residential End-Use Energy Planning System (REEPS), which was developed by the Electric Power Research Institute. In this modeling framework, appliances include essentially all residential end-uses other than space conditioning end-uses. We have defined a distinct appliance model for each end-use based on a common modeling framework provided in the REEPS software. This report details our development of the following appliance models: refrigerator, freezer, dryer, water heater, clothes washer, dishwasher, lighting, cooking and miscellaneous. Taken together, appliances account for approximately 70% of electricity consumption and 30% of natural gas consumption in the US residential sector. Appliances are thus important to those residential sector policies or programs aimed at improving the efficiency of electricity and natural gas consumption. This report is primarily methodological in nature, taking the reader through the entire process of developing the baseline for residential appliance end-uses. Analysis steps documented in this report include: gathering technology and market data for each appliance end-use and specific technologies within those end-uses, developing cost data for the various technologies, and specifying decision models to forecast future purchase decisions by households. Our implementation of the REEPS 2.1 modeling framework draws on the extensive technology, cost and market data assembled by LBL for the purpose of analyzing federal energy conservation standards. The resulting residential appliance forecasting model offers a flexible and accurate tool for analyzing the effect of policies at the national level.

Hwang, R.J,; Johnson, F.X.; Brown, R.E.; Hanford, J.W.; Kommey, J.G.

1994-05-01T23:59:59.000Z

98

http://www.procurement.vt.edu/HokieMart/hm.html Revised 12.12.13  

E-Print Network [OSTI]

) ­ Include expenses for refrigerators, freezers, fume hoods, biological safety cabinets, radiation survey for refrigerators, freezers, fume hoods, biological safety cabinets, radiation survey instruments costing $2

Buehrer, R. Michael

99

Fridges to fight childhood disease  

SciTech Connect (OSTI)

A solar-powered refrigerator/freezer has been installed in a medical center in Bhoorbaral, India. The installation and performance of the refrigerator/freezer are described.

Lerner, T.

1983-04-01T23:59:59.000Z

100

OCCUPATIONAL & ENVIRONMENTAL SAFETY SERVICES C:\\Documents and Settings\\sysdev\\Local Settings\\Temporary Internet Files\\OLK412\\Lab Equipment Release -New Format.doc  

E-Print Network [OSTI]

, autoclaves, centrifuges, refrigerators, freezers, incubators, BioSafety cabinets, and analytical equipment, refrigerators, freezers, incubators, etc. #12;OCCUPATIONAL & ENVIRONMENTAL SAFETY SERVICES C

Krovi, Venkat

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

The Technical and Economical Analysis of a Centralized Air-Conditioning System with Cold Storage Refrigeration in High-Rise Residential Buildings  

E-Print Network [OSTI]

In recent years, the application of a centralized air-conditioning system (CACS) with cold storage refrigeration in high-rise residential buildings has gradually increased. Due to the large difference between civil residential buildings...

Xiang, C.; Xie, G.

2006-01-01T23:59:59.000Z

102

DSM Electricity Savings Potential in the Buildings Sector in APP Countries  

E-Print Network [OSTI]

Programs Equipment Refrigerators and Freezers Mains Pressureclothes washers, refrigerators and freezers, fluorescentYear Updated Refrigerators Freezers Kimchi Refrigerators Air

McNeil, MIchael

2011-01-01T23:59:59.000Z

103

Potential Impact of Adopting Maximum Technologies as Minimum Efficiency Performance Standards in the U.S. Residential Sector  

SciTech Connect (OSTI)

The US Department of Energy (US DOE) has placed lighting and appliance standards at a very high priority of the U.S. energy policy. However, the maximum energy savings and CO2 emissions reduction achievable via minimum efficiency performance standards (MEPS) has not yet been fully characterized. The Bottom Up Energy Analysis System (BUENAS), first developed in 2007, is a global, generic, and modular tool designed to provide policy makers with estimates of potential impacts resulting from MEPS for a variety of products, at the international and/or regional level. Using the BUENAS framework, we estimated potential national energy savings and CO2 emissions mitigation in the US residential sector that would result from the most aggressive policy foreseeable: standards effective in 2014 set at the current maximum technology (Max Tech) available on the market. This represents the most likely characterization of what can be maximally achieved through MEPS in the US. The authors rely on the latest Technical Support Documents and Analytical Tools published by the U.S. Department of Energy as a source to determine appliance stock turnover and projected efficiency scenarios of what would occur in the absence of policy. In our analysis, national impacts are determined for the following end uses: lighting, television, refrigerator-freezers, central air conditioning, room air conditioning, residential furnaces, and water heating. The analyzed end uses cover approximately 65percent of site energy consumption in the residential sector (50percent of the electricity consumption and 80percent of the natural gas and LPG consumption). This paper uses this BUENAS methodology to calculate that energy savings from Max Tech for the U.S. residential sector products covered in this paper will reach an 18percent reduction in electricity demand compared to the base case and 11percent in Natural Gas and LPG consumption by 2030 The methodology results in reductions in CO2 emissions of a similar magnitude.

Letschert, Virginie; Desroches, Louis-Benoit; McNeil, Michael; Saheb, Yamina

2010-05-03T23:59:59.000Z

104

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

E-Print Network [OSTI]

vapor compression refrigerators and freezers), along withthe number of refrigerators and freezers in a home alongcompression refrigerators and freezers) in U.S. households.

Greenblatt, Jeffery B.

2013-01-01T23:59:59.000Z

105

Duke University Laboratory Equipment  

E-Print Network [OSTI]

prior to transport includes, but is not limited to the following: refrigerators, freezers, centrifuges

Wolpert, Robert L

106

Herb Production--Is It for You?  

E-Print Network [OSTI]

such as refrigerators, freezers, drying sheds, and dehydrators take money to buy and maintain. Specialty crop

O'Laughlin, Jay

107

umces-safety@umces.edu Hazard Communication umces-  

E-Print Network [OSTI]

umces- safety@umces.edu Hazardous chemicals can be found in laboratory refrigerators, freezers, cabinets

Boynton, Walter R.

108

umces-safety@umces.edu Hazard Communication umces-  

E-Print Network [OSTI]

Communication umces- safety@umces.edu Hazardous chemicals can be found in laboratory refrigerators, freezers

Boynton, Walter R.

109

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

SciTech Connect (OSTI)

The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

McNeil, Michael A.; Iyer, Maithili

2009-05-30T23:59:59.000Z

110

Technical support document: Energy conservation standards for consumer products: Refrigerators and furnaces including: environmental impacts regulatory impact analysis  

SciTech Connect (OSTI)

The National Appliance Energy Conversation Act (NAECA) of 1987 (P.L. 100-12) establishes energy efficiency standards for 13 types of consumer products. The legislation requires the Department of Energy (DOE) to consider new or amended standards on these and other types of products at specified times. DOE is currently selecting standards for two types of products: refrigerators, refrigerator-freezers, and freezers; and small gas furnaces. This Technical Support Document presents the methodology, data and results from the analysis of the energy and economic impacts of the proposed standards. 8 refs., 39 figs., 135 tabs.

Not Available

1989-11-01T23:59:59.000Z

111

Malone cycle refrigerator development  

SciTech Connect (OSTI)

This paper describes the progress made in demonstrating a Malone Cycle Refrigerator/Freezer. The Malone cycle is similar to the Stirling cycle but uses a supercritical fluid in place of real gas. In the approach, solid-metal diaphragms are used to seal and sweep the working volumes against the high working fluid pressures required in Malone cycle machines. This feature eliminates the friction and leakage that accounted for nearly half the losses in the best piston-defined Malone cycle machines built to date. The authors successfully built a Malone cycle refrigerator that: (1) used CO{sub 2} as the working fluid, (2) operated at pressures up to 19.3 Mpa (2,800 psi), (3) achieved a cold end metal temperatures of {minus}29 C ({minus}20 F), and (4) produced over 400 Watts of cooling at near ambient temperatures. The critical diaphragm components operated flawlessly throughout characterization and performance testing, supporting the conclusion of high reliability based on analysis of fatigue date and actual strain measurements.

Shimko, M.A.; Crowley, C.J.

1999-07-01T23:59:59.000Z

112

RADIATION SAFETY MANUAL (REVISED MARCH 2010) 103 USER RADIATION SURVEY REPORT  

E-Print Network [OSTI]

on hand, is the isotope secured? e. Refrigerator and other storage area logs current? f. Refrigerators/freezers

113

EA-1138: Final Environmental Assessment | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

EA-1138: Final Environmental Assessment Proposed Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers This Environmental Assessment (EA)...

114

COMBINING DIVERSE DATA SOURCES FOR CEDSS, AN AGENT-BASED MODEL OF DOMESTIC ENERGY DEMAND  

E-Print Network [OSTI]

the heating system, a cooker, refrigerator and washinghere are heating systems, cookers, cold appliances (heating systems, cookers, refrigerators, freezers, washing

Gotts, Nicholas Mark; Polhill, Gary; Craig, Tony; Galan-Diaz, Carlos

2014-01-01T23:59:59.000Z

115

Energy use of US residential refrigerators and freezers: function derivation based on household and climate characteristics  

E-Print Network [OSTI]

Residential Energy Consumption Survey (RECS), U.S. Energyod for estimating field energy consumption of US residentialconsumption survey—detailed tables. Residential Energy Con- sumption Survey (RECS), U.S.

Greenblatt, Jeffery

2013-01-01T23:59:59.000Z

116

Towards a Sustainable Energy Balance: Progressive Efficiency and the Return of Energy Conservation  

E-Print Network [OSTI]

data. Listings for refrigerators and freezers as of May 1,not only do some refrigerator- freezers offer thru-the-door-In the case of refrigerator-freezer labels, for example, the

Harris, Jeff

2008-01-01T23:59:59.000Z

117

Towards a Sustainable Energy Balance: Progressive Efficiency and the Return of Energy Conservation  

E-Print Network [OSTI]

Data. Listings for refrigerators and freezers as of May 1,not only do some refrigerator- freezers offer thru-the-door-In the case of refrigerator-freezer labels, for example, the

Harris, Jeffrey; Diamond, Rick; Iyer, Maithili; Payne, Christopher; Blumstein, Carl; Siderius, Hans-Paul

2007-01-01T23:59:59.000Z

118

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in the United States  

E-Print Network [OSTI]

Historical Shipment' Compact RefrigeratorRefrigerator?Freezer Refrigerator?Freezer and Freezers NOPR National Impact Analysis Spreadsheet, USDOE (2010g)  Price Source Location By Category* Shipments Table 8.4.x Lifetime 'Historical 

Bojda, Nicholas

2011-01-01T23:59:59.000Z

119

Global warming impacts of ozone-safe refrigerants and refrigeration, heating, and air-conditioning technologies  

SciTech Connect (OSTI)

International agreements mandate the phase-out of many chlorine containing compounds that are used as the working fluid in refrigeration, air-conditioning, and heating equipment. Many of the chemical compounds that have been proposed, and are being used in place of the class of refrigerants eliminated by the Montreal Protocol are now being questioned because of their possible contributions to global warming. Natural refrigerants are put forth as inherently superior to manufactured refrigerants because they have very low or zero global warming potentials (GWPs). Questions are being raised about whether or not these manufactured refrigerants, primarily hydrofluorocarbons (HFCs), should be regulated and perhaps phased out in much the same manner as CFCs and HCFCs. Several of the major applications of refrigerants are examined in this paper and the results of an analysis of their contributions to greenhouse warming are presented. Supermarket refrigeration is shown to be an application where alternative technologies have the potential to reduce emissions of greenhouse gases (GHG) significantly with no clear advantage to either natural or HFC refrigerants. Mixed results are presented for automobile air conditioners with opportunities to reduce GHG emissions dependent on climate and comfort criteria. GHG emissions for hermetic and factory built systems (i.e. household refrigerators/freezers, unitary equipment, chillers) are shown to be dominated by energy use with much greater potential for reduction through efficiency improvements than by selection of refrigerant. The results for refrigerators also illustrate that hydrocarbon and carbon dioxide blown foam insulation have lower overall effects on GHG emissions than HFC blown foams at the cost of increased energy use.

Fischer, S.; Sand, J.; Baxter, V.

1997-12-01T23:59:59.000Z

120

Lab Safety, Biological Safety and Bloodborne Pathogen Training  

E-Print Network [OSTI]

and on the doors of refrigerators, freezers, microwaves and dewars · You should be wearing the correct Personal

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Umea University Education Short-Term Program  

E-Print Network [OSTI]

refrigerators, freezers and kitchen utensils that you can share. The housing with IHO includes: · Private room

Viglas, Anastasios

122

Trends in the cost of efficiency for appliances and consumer electronics  

E-Print Network [OSTI]

Appliance Refrigerators and Freezers Room Air ConditionersPCU3352283352285 a The refrigerator and freezer price trendRefrigerators, Refrigerator-Freezers, and Freezers (Final

Desroches, Louis-Benoit

2013-01-01T23:59:59.000Z

123

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in the United States  

E-Print Network [OSTI]

Taken together, refrigerators and freezers account for 8.9%Freezers   Refrigerator and Freezer Cases  without Doors Refrigerator, Refrigerator-Freezer and Freezers Rulemaking

Bojda, Nicholas

2011-01-01T23:59:59.000Z

124

Space Heaters, Computers, Cell Phone Chargers: How Plugged In Are Commercial Buildings?  

E-Print Network [OSTI]

Refrigerators, Refrigerator-Freezers & Freezers. DOE/EE-refrigerator, commercial speakers switch, ethernet freezer,refrigerator, microscope, autoclave, shaker/stirrer, lab freezer,

Sanchez, Marla; Webber, Carrie; Brown, Richard; Busch, John; Pinckard, Margaret; Roberson, Judy

2007-01-01T23:59:59.000Z

125

Development of energy-efficiency standards for Indian refrigerators  

SciTech Connect (OSTI)

The application of advanced techniques in engineering simulation and economic analysis for the development of efficiency standards for Indian refrigerators is illustrated in this paper. A key feature of this methodology is refrigerator simulation to generate energy savings for a set of energy-efficient design options and life-cycle cost (LCC) analysis with these design options. The LCC of a refrigerator is analyzed as a function of five variables: nominal discount rate, fuel price, appliance lifetime, incremental price, and incremental energy savings. The frequency of occurrence of the LCC minimum at any design option indicates the optimum efficiency level or range. Studies carried out in the US and European Economic Community show that the location of the LCC minimum under different scenarios (e.g., variable fuel price, life-time, discount rate, and incremental price) is quite stable. Thus, an efficiency standard can be developed based on the efficiency value at the LCC minimum. This paper examines and uses this methodology in developing efficiency standards for Indian refrigerators. The potential efficiency standard value is indicated to be 0.65 kWh/day for a 165-liter, CFC-based, manual defrost, single-door refrigerator-freezer.

Bhatia, P.

1999-07-01T23:59:59.000Z

126

Radioisotope Laboratory Techniques Environmental Health & Safety  

E-Print Network [OSTI]

. Work Areas e. Refrigerators / Freezers f. Waste Areas #12;Lab Safety Checklist 1. Caution Signs a. Doors b. Hoods c. Hardware d. Work Areas e. Refrigerators / Freezers f. Waste Areas #12;Lab Safety Checklist 1. Caution Signs a. Doors b. Hoods c. Hardware d. Work Areas e. Refrigerators / Freezers f. Waste

Slatton, Clint

127

STATE OF CALIFORNIA --THE NATURAL RESOURCES AGENCY ARNOLD SCHWARZENEGGER, Governor CALIFORNIA ENERGY COMMISSION  

E-Print Network [OSTI]

for refrigerators, freezers, clothes washers, dishwashers and room air conditioners closed on December 6, 2010 for the following appliance categories will close on December 31, 2010: · Heating, Ventilating and Air Conditioning Program for #12;California that provides rebates to encourage the replacement of inefficient residential

128

Analysis of household refrigerators for different testing standards  

SciTech Connect (OSTI)

This study highlights the salient differences among various testing standards for household refrigerator-freezers and proposes a methodology for predicting the performance of a single evaporator-based vapor-compression refrigeration system (either refrigerator or freezer) from one test standard (where the test data are available-the reference case) to another (the alternative case). The standards studied during this investigation include the Australian-New Zealand Standard (ANZS), the International Standard (ISO), the American National Standard (ANSI), the Japanese Industrial Standard (JIS), and the Chinese National Standard (CNS). A simple analysis in conjunction with the BICYCLE model (Bansal and Rice 1993) is used to calculate the energy consumption of two refrigerator cabinets from the reference case to the alternative cases. The proposed analysis includes the effect of door openings (as required by the JIS) as well as defrost heaters. The analytical results are found to agree reasonably well with the experimental observations for translating energy consumption information from one standard to another.

Bansal, P.K. [Univ. of Auckland (New Zealand). Dept. of Mechanical Engineering; McGill, I. [Fischer and Paykel Ltd., Auckland (New Zealand)

1995-08-01T23:59:59.000Z

129

Fridge of the future: ORNL`s refrigeration R&D  

SciTech Connect (OSTI)

Fears about warming the globe may change the way foods are chilled. Concern about global warming, as expressed in the President`s Climate Change Action Plan of 1993, is the latest motivation for putting future American refrigerators and freezers on a strict energy diet. A current national goal is to design an environmentally sound refrigerator-freezer by 1998 that uses half as much energy as 1993 models. Interest in designing a more energy-efficient refrigerator is not new. It first became a goal almost 20 years ago. In the 1970`s the United States was relying on increasingly unstable supplies of imported oil for fuel, and energy prices began to rise. Utilities balked at building additional power plants because of rising costs and investment risks. As a result, a premium was placed on developing energy-efficient appliances, culminating in the passage of the National Appliance Energy Conservation Act of 1987. In the late 1980`s refrigerator design was again a target of engineers because of the need to change the refrigerant and insulation used. The reason: the Montreal Protocol called for phasing out of substances containing chlorofluorocarbons (CFCs) by the year 2000 because they were thought to be destroying the earth`s stratospheric ozone layer. Ozone shields humans from solar rays that can cause skin cancer and cataracts. Among the CFCs to be phased out are common refrigerants like R-12 and the refrigerator insulation blowing agent R-11.

Krause, C.

1995-12-31T23:59:59.000Z

130

Field performance of residential refrigerators: A comparison with the laboratory test  

SciTech Connect (OSTI)

The field electricity use of 209 refrigerators was compared to their labeled consumption. The mean field use of all units was 1009 kWh/year, 882 kWh/year for top-freezers, and 1366 kWh/year for side-by-sides. There was considerable scatter in the results but, in general, the label overpredicted field use. The relationship could be best described with the formula, Annual Field Use = 0.94 [times] (Annual Label Us) - 85. For a typical unit with a labeled use of 1160 kWh/year, the field use was about 15% lower. There was considerable seasonality in energy use: the peak weeks generally occurred around the beginning of August. However, there was no simple relationship between the label value and the peak-week consumption.

Meier, A.; Jansky, R.

1991-05-01T23:59:59.000Z

131

Field performance of residential refrigerators: A comparison with the laboratory test  

SciTech Connect (OSTI)

The field electricity use of 209 refrigerators was compared to their labeled consumption. The mean field use of all units was 1009 kWh/year, 882 kWh/year for top-freezers, and 1366 kWh/year for side-by-sides. There was considerable scatter in the results but, in general, the label overpredicted field use. The relationship could be best described with the formula, Annual Field Use = 0.94 {times} (Annual Label Us) - 85. For a typical unit with a labeled use of 1160 kWh/year, the field use was about 15% lower. There was considerable seasonality in energy use: the peak weeks generally occurred around the beginning of August. However, there was no simple relationship between the label value and the peak-week consumption.

Meier, A.; Jansky, R.

1991-05-01T23:59:59.000Z

132

Assessment of China's Energy-Saving and Emission-Reduction Accomplishments and Opportunities During the 11th Five Year Plan  

E-Print Network [OSTI]

televisions, refrigerators and freezers, mobile phones,dishwashers, refrigerators and freezers and clothes washersand 48 million refrigerator/freezers with exports of 20

Levine, Mark D.

2010-01-01T23:59:59.000Z

133

Prioritizing Climate Change Mitigation Alternatives: Comparing Transportation Technologies to Options in Other Sectors  

E-Print Network [OSTI]

heaters Walk-in refrigerators and freezers Single-voltagewashers, commercial refrigerators and freezers, commercialDay Domestic RefrigeratorFreezer. ” ASHRAE Transactions ,

Lutsey, Nicholas P.

2008-01-01T23:59:59.000Z

134

An Evaluation of the Effects of Refrigerant Charge on a Residential Central Air Conditioner with Orifice Expansion  

E-Print Network [OSTI]

had one row of tubes with spine fins spaced at 20 per inch. The face area of the coil was 20.94 ft with refrigerant tube sizes of 3/8". The outdoor fan was located on the top of the outdoor coil. The fan specifications are given in Table 2.... 2.5 Table 2.1 - Fan Specification Refrigerant Side A schematic of the refrigerant circuit is shown in Figure 2.3. Refrigerant pressures were monitored at the 6 points shown with the use of 0-300 psig pressure transducers. To accurately measure...

O'Neal, D. L.; Ramsey, C. J.; Farzad, M.

1989-01-01T23:59:59.000Z

135

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

E-Print Network [OSTI]

for Refrigerators and Air Conditioners in India. Michael A.followed by room air conditioners. Both of these appliancesfrost-free units. Room air conditioners in India have

McNeil, Michael A.

2010-01-01T23:59:59.000Z

136

Environmental Health and Safety Environmental Health Laboratory Assessment  

E-Print Network [OSTI]

: Category Item Comments (description, location, etc.) Lab refrigerators/freezers/microwaves labeled: "No Food" "No Flammables" (unless a flammable rated refrigerator is present) Restricted areas

137

EA-0372: Final Environmental Assessment | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

the environmental impacts resulting from new or amended energy-efficiency standards for refrigerators, refrigerator-freezers, freezers, small gas furnaces, and television sets as...

138

LABORATORY CLOSEOUT CHECKLIST Northwestern University Vice President for Research Office for Research Safety  

E-Print Network [OSTI]

Clean and decontaminate refrigerators/freezers Transfer responsibility to: P:\\LSS Resources. Be sure to check all drawers, cabinets, cupboards, refrigerators, etc. Gas Cylinders Identify contents

Shull, Kenneth R.

139

EA-1138: Finding of No Significant Impact | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

EA-1138: Finding of No Significant Impact Proposed Energy-Conservation Standards for Refrigerators, Refrigerator - Freezers, and Freezers Finding of No Significant Impact for...

140

STATE OF CALIFORNIA ENERGY RESOURCES CONSERVATION  

E-Print Network [OSTI]

formerly finished with white enamel, but now often colored, such as refrigerators, freezers, clothes; Irrigation equipment Commercial dishwashers; Recirculation pumps; Refrigeration condensing units #12

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

California Energy Resources Conservation and Development Commission  

E-Print Network [OSTI]

Division Regulations for Appliance Efficiency Standards Re 1ating to Refrigerators, Refrigerator-Freezers sold in California: (a) Refrigerators, refrigerator-freezers, and freezers, which are directly operated on the appliance. ~ (b) Refrigerators and Freezers (1) "Automatic defrost system" means the defrosting action

142

EA-1643: Finding of No Significant Impact  

Broader source: Energy.gov [DOE]

Energy Conservation Program for Commercial and Industrial Equipment: Energy Conservation Standards for Commercial Ice-Cream Freezers; Self-Contained Commercial Refrigerators, Commerical Freezers, and Commercial Refrigerator-Freezers without Doors; and Remote Condensing Commercial Refrigerators, Commercial Freezers, and Commercial Refrigerator-Freezers

143

Molecular Biology Building North Lobby Entrance  

E-Print Network [OSTI]

Facilities MBB 1.420 and 1.426 Cryostat North Refrigerators/Freezers Sample Drop off Light Scopes(1) Night

Ben-Yakar, Adela

144

Elmira Stove Works: Proposed Penalty (2011-CE-1407)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that Elmira Stove Works failed to certify refrigerator-freezers as compliant with the energy conservation standards.

145

OCCUPATIONAL & ENVIRONMENTAL SAFETY SERVICES C:\\Documents and Settings\\sysdev\\Local Settings\\Temporary Internet Files\\OLK412\\Equipment Servicing Policy -New Format.doc  

E-Print Network [OSTI]

but is not limited to fume hoods, autoclaves, centrifuges, refrigerators, freezers, and incubators (hereafter, refrigerators, freezers, incubators, etc. 4.3 Materials: Hazardous, radiological, or biological materials 4 the equipment. For example materials may remain within a refrigerator or freezer while it is being serviced

Krovi, Venkat

146

Duquesne Light Company- Residential Energy Efficiency Program  

Broader source: Energy.gov [DOE]

Duquesne Light provides rebates to its residential customers for purchasing and installing energy-saving equipment. Eligible equipment includes dehumidifiers, freezers, refrigerators, air...

147

Use of Residential Smart Appliances for Peak-Load Shifting and Spinning Reserves Cost/Benefit Analysis  

SciTech Connect (OSTI)

In this report, we present the results of an analytical cost/benefit study of residential smart appliances from a utility/grid perspective in support of a joint stakeholder petition to the ENERGY STAR program within the Environmental Protection Agency (EPA) and Department of Energy (DOE). The goal of the petition is in part to provide appliance manufacturers incentives to hasten the production of smart appliances. The underlying hypothesis is that smart appliances can play a critical role in addressing some of the societal challenges, such as anthropogenic global warming, associated with increased electricity demand, and facilitate increased penetration of renewable sources of power. The appliances we consider include refrigerator/freezers, clothes washers, clothes dryers, room air-conditioners, and dishwashers. The petition requests the recognition that providing an appliance with smart grid capability, i.e., products that meet the definition of a smart appliance, is at least equivalent to a corresponding five percent in operational machine efficiencies. It is then expected that given sufficient incentives and value propositions, and suitable automation capabilities built into smart appliances, residential consumers will be adopting these smart appliances and will be willing participants in addressing the aforementioned societal challenges by more effectively managing their home electricity consumption. The analytical model we utilize in our cost/benefit analysis consists of a set of user-definable assumptions such as the definition of on-peak (hours of day, days of week, months of year), the expected percentage of normal consumer electricity consumption (also referred to as appliance loads) that can shifted from peak hours to off-peak hours, the average power rating of each appliance, etc. Based on these assumptions, we then formulate what the wholesale grid operating-cost savings, or benefits, would be if the smart capabilities of appliances were invoked, and some percentage of appliance loads were shifted away from peak hours to run during off-peak hours, and appliance loads served power-system balancing needs such as spinning reserves that would otherwise have to be provided by generators. The rationale is that appliance loads can be curtailed for about ten minutes or less in response to a grid contingency without any diminution in the quality of service to the consumer. We then estimate the wholesale grid operating-cost savings based on historical wholesale-market clearing prices (location marginal and spinning reserve) from major wholesale power markets in the United States. The savings derived from the smart grid capabilities of an appliance are then compared to the savings derived from a five percent increase in traditional operational machine efficiencies, referred to as cost in this report, to determine whether the savings in grid operating costs (benefits) are at least as high as or higher than the operational machine efficiency credit (cost).

Sastry, Chellury; Pratt, Robert G.; Srivastava, Viraj; Li, Shun

2010-12-01T23:59:59.000Z

148

Availability of refrigerants for heat pumps in Europe  

E-Print Network [OSTI]

grids Smart cities #12;8 Residential HPs Refrigerants Use of aero-geo- +hydrothermal renewable energy cooling and heating Residential Future: Heating of electric cars and cooling the batteries Future: Smart

Oak Ridge National Laboratory

149

Research and development of energy-efficient appliance motor-compressors. Final report. Volume 1: executive summary  

SciTech Connect (OSTI)

The accomplishments of the refrigerator/freezer motor-compressor development program are highlighted. The experimental program involved making numerous incremental changes to an existing compresssor design. The refrigerator/freezer motor compressor experimental development, room air conditioner experimental development, market study, and phase II field demonstration program are summarized. (MHR)

Nelson, R.T.; MacCarthy, P.W.

1980-09-01T23:59:59.000Z

150

LAB EQUIPMENT SERVICE POLICY This policy has not yet been vetted or formatted as part of the policy review project, however, all  

E-Print Network [OSTI]

but not limited to fume hoods, autoclaves, centrifuges, refrigerators, freezers, incubators, etc. Materials, or stored. This may include but is not limited to fume hoods, autoclaves, centrifuges, refrigerators, freezers, and incubators (hereafter "equipment'). This procedure applies to equipment located within both

Krovi, Venkat

151

ENERGY & ENVIRONMENT DIVISION. ANNUAL REPORT FY 1980  

E-Print Network [OSTI]

kWh) (kWh) b b Refrigerator and Freezer (kWh) Source: Unionseveral months for refrigerators and freezers to a maximumPart 2, June, 1980. Refrigerator/freezers Freezers Clothes

Authors, Various

2010-01-01T23:59:59.000Z

152

Lumbee River EMC- Residential and Commercial Energy Efficiency Program  

Broader source: Energy.gov [DOE]

Lumbee River EMC (LREMC) offers rebates to its residential customers who purchase and install qualified energy efficient products or services. Rebates are available for water heaters, refrigerator...

153

Central New Mexico Electric Cooperative- Residential Energy Efficiency Rebate Program  

Broader source: Energy.gov [DOE]

Central New Mexico Electric Cooperative (CNMEC) provides an incentive for its residential members to purchase energy efficient water heaters, clothes washers, dishwashers, refrigerators, and...

154

Lake Region Electric Cooperative- Residential Energy Efficiency Rebate Program  

Broader source: Energy.gov [DOE]

Lake Region Electric Cooperative (LREC) offers a variety of rebates for residential customers to improve the energy efficiency of homes. Rebates are available for Energy Star refrigerators and...

155

Orange and Rockland Utilities (Electric)- Residential Appliance Recycling Program  

Broader source: Energy.gov [DOE]

Orange and Rockland Utilities provides rebates for residential customers for recycling older, inefficient refrigerators and freezers. All appliances must meet the program requirements listed on the...

156

Orange and Rockland Utilities (Electric)- Residential Efficiency Program (New York)  

Broader source: Energy.gov [DOE]

Orange and Rockland Utilities provides rebates for residential customers for recycling older, inefficient refrigerators and freezers. All appliances must meet the program requirements listed on the...

157

China Refrigerator Information Label: Specification Development and Potential Impact  

SciTech Connect (OSTI)

In the last five years, China's refrigerator market has grown rapidly, and now urban markets are showing signs of saturation, with ownership rates in urban households reaching 92%. Rural markets continue to grow from a much lower base. As a result of this growth, the Chinese government in 2006 decided to revise the refrigerator standards and its associated efficiency grades for the mandatory energy information label. In the Chinese standards process, the efficiency grades for the information label are tied to the minimum standards. Work on the minimum standards revision began in 2006 and continued through the first half of 2007, when the draft standard was completed under the direction of the China National Institute of Standardization (CNIS). Development of the information label grades required consideration of stakeholder input, continuity with the previous grade classification, ease of implementation, and potential impacts on the market. In this process, CLASP, with the support of METI/IEEJ, collaborated with CNIS to develop the efficiency grades, providing technical input to the process, comment and advice on particular technical issues, and evaluation of the results. After three months of effort and three drafts of the final grade specifications, this work was completed. In addition, in order to effectively evaluate the impact of the label on China's market, CLASP further provided assistance to CNIS to collect data on both the efficiency distribution and product volume distribution of refrigerators on the market. The new information label thresholds to be implemented in 2008 maintain the approach first adopted in 2005 of establishing efficiency levels relative to the minimum standard, but increased the related required efficiency levels by 20% over those established in 2003 and implemented in 2005. The focus of improvement was on the standard refrigerator/freezer (class 5), which constitutes the bulk of the Chinese market. Indeed, the new requirements to achieve grade 1 on the label are now virtually as stringent as those for US Energy Star-qualified or EU A-grade refrigerators. When the energy information label went into effect in March 2005, refrigerator manufacturers were required to display their declared level of efficiency on the label and report it to the China Energy Label Center (CELC), a newly established unit of CNIS responsible for label program management. Because of the visible nature of the label, it was found, through a METI/IEEJ-supported study, that MEPS non-compliance dropped from 4% to zero after the label became mandatory, and that the percentage of higher-grade refrigerators increased. This suggests that the label itself does have potential for shifting the market to higher-efficiency models (Lin 2007). One challenge, however, of assessing this potential impact is the lack of a comprehensive baseline of market efficiency and a program to evaluate the market impact on a yearly basis. As a result, the impact evaluation in this study draws upon the market transformation experience of the related EU energy information label, for which quantitative assessments of its market impact exist. By assuming a parallel process unfolding in China, it is possible to look at the potential impact of the label to 2020. The results of the analysis demonstrates that a robust market transformation program in China focused on the energy information label could save substantial amounts of electricity by 2020, totaling 16.4 TWh annually by that year, compared to a case in which the efficiency distribution of refrigerators was frozen at the 2007 level. Remarkably, the impact of a successful market transformation program with the label would essentially flatten the consumption of electricity for refrigerator use throughout most of the next decade, despite the expectations of continued growth in total stock by nearly 190 million units. At the end of this period, total consumption begins to rise again, as the least efficient of the units have been mostly removed from the market. Such a level of savings would reduce CO{sub

Fridley, David; Fridley, David; Zheng, Nina; Zhou, Nan; Aden, Nathaniel; Lin, Jiang; Jianhong, Cheng; Sakamoto, Tomoyuki

2008-02-01T23:59:59.000Z

158

Malone refrigeration  

SciTech Connect (OSTI)

Malone refrigeration is the use of a liquid near its critical points without evaporations as working fluid in a regenerative or recuperative refrigeration cycle such as the Stirling and Brayton cycles. It's potential advantages include compactness, efficiency, an environmentally benign working fluid, and reasonable cost. One Malone refrigerator has been built and studied; two more are under construction. Malone refrigeration is such a new, relatively unexplored technology that the potential for inventions leading to improvements in efficiency and simplicity is very high.

Swift, G.W.

1993-01-01T23:59:59.000Z

159

Nostalgia Products: Proposed Penalty (2014-CE-14017)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that Nostalgia Products Group, LLC failed to certify a variety of consumer refrigerators and refrigerator-freezers as compliant with the applicable energy conservation standards.

160

Sanyo Electric: Proposed Penalty (2010-CE-1210)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that Sanyo Electric Co. failed to certify a variety of refrigerators, refrigerator-freezers, and freezers as compliant with the applicable energy conservation standards.

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

This report has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Techni-  

E-Print Network [OSTI]

. DOMESTIC REFRIGERATORS/FREEZERS ......... ......... 9 3.1 INTRODUCTION ......................... 9 3 TABLE OF REFRIGERANTS AND CHEMICAL SYMBOLS ............ xi ABBREVIATIONS, ACRONYMS, AND INITIALISMS 3.6 COMMENTS AND CAVEATS ................... 14 iii #12;4. HOUSEHOLD FREEZERS

Oak Ridge National Laboratory

162

Nostalgia Products: Order (2014-CE-14017)  

Broader source: Energy.gov [DOE]

DOE ordered Nostalgia Products Group, LLC to pay a $8,000 civil penalty after finding Nostalgia Products had failed to certify that certain models of refrigerators and refrigerator-freezers comply with the applicable energy conservation standards.

163

Mackle Company: Order (2010-SE-0106)  

Broader source: Energy.gov [DOE]

DOE ordered Mackle Company, Inc. to pay a $27,200 civil penalty after finding the company had failed to certify that a variety of refrigerators, refrigerator-freezers, and freezers comply with the applicable energy conservation standards.

164

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network [OSTI]

RefrigerationRefrigerationRefrigeration coursecourse # 424503.0# 424503.0 v.v. 20122012 8. Heat pumps, heat pipes, cold thermal energy storage Ron on a vapour-compression cycle) /heat_pump.g Heat pumps make use of low- temperature (waste) heat, replacing/vcmfiles/ electricity!) for heating and air conditioning purposes Heat pumps became popular in ://www.bge.c Heat pumps

Zevenhoven, Ron

165

Malone refrigeration  

SciTech Connect (OSTI)

Malone refrigeration is the use of a liquid near its critical point, without evaporation, as working fluid in a refrigeration cycle such as the Stirling cycle. We discuss relevant properties of appropriate liquids, and describe two Malone refrigerators. The first completed several years ago, established the basic principles of use of liquids in such cycles. The second, now under construction, is a linear, free-piston machine.

Swift, G W

1992-01-01T23:59:59.000Z

166

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network [OSTI]

at constant p #12;Stirling cycle, Stirling engineStirling cycle, Stirling engine See for principle also http://www.cs.sbcc.net/~physics/flash/heatengines/stirlingRefrigerationRefrigerationRefrigeration coursecourse # 424503.0# 424503.0 v.v. 20122012 5. Low temperatures,p liquefied gases Ron Zevenhoven ��bo Akademi University Thermal and Flow Engineering Laboratory / Värme- och strömningsteknik tel. 3223 ; ron

Zevenhoven, Ron

167

Malone refrigeration  

SciTech Connect (OSTI)

Malone refrigeration is the use of a liquid near its critical points without evaporations as working fluid in a regenerative or recuperative refrigeration cycle such as the Stirling and Brayton cycles. It`s potential advantages include compactness, efficiency, an environmentally benign working fluid, and reasonable cost. One Malone refrigerator has been built and studied; two more are under construction. Malone refrigeration is such a new, relatively unexplored technology that the potential for inventions leading to improvements in efficiency and simplicity is very high.

Swift, G.W.

1993-06-01T23:59:59.000Z

168

PNM- Residential Energy Efficiency Rebate Program  

Broader source: Energy.gov [DOE]

PNM offers incentives for residential customers to improve the efficiency of eligible homes. PNM will provide a $50 rebate for the proper recycling of old refrigerators or freezers. Customers who...

169

National Grid (Electric)- Residential Energy Efficiency Rebate Programs (Upstate New York)  

Broader source: Energy.gov [DOE]

National Grid residential electric customers in Upstate New York are eligible for several incentives offerings. Rebates are available for properly recycling inefficient refrigerators and for the...

170

NBSIFI 86-3373 Impact of Refrigerant Property  

E-Print Network [OSTI]

of performance prediction to refrigerant properties for a residential, split heat pump operating in the cooling mode. The NBS steady-state heat pump model, HPSIM, was used in this study. The individual influence and refrigerant mass flow rate are also given in the report. iii #12;Discrepancy between heat pump laboratory test

Oak Ridge National Laboratory

171

Quantifying the Effect of the Principal-Agent Problem on US Residential Energy Use  

E-Print Network [OSTI]

Residential Energy Consumption Survey (U.S. EIA 2004a) toand energy consumption for refrigeration are from RECS (U.S.Residential Energy Consumption Survey 2001 (RECS 2001) (U.S.

Murtishaw, Scott; Sathaye, Jayant

2006-01-01T23:59:59.000Z

172

Samsung: ENERGY STAR Referral (RF26VAB)  

Broader source: Energy.gov [DOE]

DOE referred the matter of Samsung refrigerator-freezer model RF26VAB to the EPA for appropriate action after DOE testing showed that the model does not meet the ENERGY STAR specification.

173

Department of Energy to Take Steps to Remove ENERGY STAR Label...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

to save energy and money with their appliances," said DOE General Counsel Scott Blake Harris. "We have found that these refrigerator-freezer models do not deliver the energy and...

174

Elmira Stove Works: Order (2011-CE-1407)  

Broader source: Energy.gov [DOE]

DOE ordered Elmira Stove Works to pay a $6,000 civil penalty after finding Elmira Stove Works had failed to certify that certain models of refrigerator-freezers comply with the applicable energy conservation standard.

175

RESIDENTIAL EXCHANGE  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

establishes the right of Pacific Northwest electric utilities to participate in the Residential Exchange Program that provides wholesale power cost benefits for residential and...

176

INSTALLATION CERTIFICATE CF-6R-MECH-26-HERS Refrigerant Charge Verification -Alternate Measurement Procedure (Page 1 of 2)  

E-Print Network [OSTI]

INSTALLATION CERTIFICATE CF-6R-MECH-26-HERS Refrigerant Charge Verification - Alternate Measurement are specified in Reference Residential Appendix RA3.2. If refrigerant charge verification is required-MECH-26-HERS Refrigerant Charge Verification - Alternate Measurement Procedure (Page 2 of 2) Site Address

177

sttesuhcassa RESIDENTIAL  

E-Print Network [OSTI]

University Apartments To Amherst Center RON TNASAELPHT TS CENTRAL RESIDENTIAL AREA To Tillson Farm RESIDENTIAL AREA Lorden Field ATHLETIC FIELDS To Telecom, UMass Outreach & UMass Extension at 101 University Drive NORTHEAST RESIDENTIAL AREA ORCHARD HILL RESIDENTIAL AREA Chabad House HAIGIS MALL Newman Center

Schweik, Charles M.

178

sttesuhcassa RESIDENTIAL  

E-Print Network [OSTI]

Gordon To Amherst Center RON TNASAELPHT TS CENTRAL RESIDENTIAL AREA To Tillson Farm & Intermediate ORCHARD HILL DR. Track & Field ACO SDT KKG SK ADP IGU ZBT BUTTERFIELDTERRACE DZ SOUTHWEST RESIDENTIAL AREA NORTHEAST RESIDENTIAL AREA ORCHARD HILL RESIDENTIAL AREA Chabad House HAIGIS MALL Newman Center Textbook

Mountziaris, T. J.

179

Initial Score: The UCSF LivingGreen Office Program seeks to recognize UCSF offices that have  

E-Print Network [OSTI]

unnecessary refrigerators, space heaters and other appliances OR replaced all refrigerators/freezers older than 7 years Age of Refrigerator: Contact livinggreen@ucsf.edu to assess your refrigerator if over 7 years old and get you involved in our refrigerator rebate program My office does not use CRT computer

Yamamoto, Keith

180

Global residential appliance standards  

SciTech Connect (OSTI)

In most countries, residential electricity consumption typically ranges from 20% to 40% of total electricity consumption. This energy is used for heating, cooling, refrigeration and other end-uses. Significant energy savings are possible if new appliance purchases are for models with higher efficiency than that of existing models. There are several ways to ensure or encourage such an outcome, for example, appliance rebates, innovative procurement, and minimum efficiency standards. This paper focuses on the latter approach. At the present time, the US is the only country with comprehensive appliance energy efficiency standards. However, many other countries, such as Australia, Canada, the European Community (EC), Japan and Korea, are considering enacting standards. The greatest potential impact of minimum efficiency standards for appliances is in the developing countries (e.g., China and India), where saturations of household appliances are relatively low but growing rapidly. This paper discusses the potential savings that could be achieved from global appliance efficiency standards for refrigerators and freezers. It also could be achieved from global appliance efficiency standards for refrigerators and freezers. It also discusses the impediments to establishing common standards for certain appliance types, such as differing test procedures, characteristics, and fuel prices. A methodology for establishing global efficiency standards for refrigerators and freezers is described.

Turiel, I.; McMahon, J.E. (Lawrence Berkeley Lab., CA (United States)); Lebot, B. (Agence Francaise pour la Maitrise de l'Energie, Valbonne (France))

1993-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Residential appliances technology atlas  

SciTech Connect (OSTI)

Residential appliance technology and efficiency opportunities for refrigerators and freezers, cooking appliances, clothes washers and dryers, dishwashers, and some often-ignored household devices such as spas, pool pumps, waterbed heaters, televisions, and home computers are thoroughly covered in this Atlas. The US appliance market, fuel shares, efficiency standards, labeling, and advances in home automation, design for recycling, and CFC issues are also discussed. The resource section contains lists of appliance manufacturers and distributors, and trade, professional, and governmental organizations, a summary of key resources for further information, and an index.

NONE

1994-12-31T23:59:59.000Z

182

ARTI refrigerant database  

SciTech Connect (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M.

1996-11-15T23:59:59.000Z

183

ARTI refrigerant database  

SciTech Connect (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilities access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

1999-01-01T23:59:59.000Z

184

ARTI refrigerant database  

SciTech Connect (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M.

1996-07-01T23:59:59.000Z

185

Assessment of Environmentally Friendly Refrigerants for Window Air Conditioners  

SciTech Connect (OSTI)

This paper presents technical assessment of environmentally friendly refrigerants for window air conditioners that currently use refrigerant R410A for residential and commercial applications. The alternative refrigerants that are studied for its replacement include R32, R600a, R290, R1234yf, R1234ze and a mixture of R32 (90% molar concentration) and R125 (10% molar concentration). Baseline experiments were performed on a window unit charged with R410A. The ORNL Heat Pump Design Model was calibrated with the baseline data and was used to assess the comparative performance of the WAC with alternative refrigerants. The paper discusses the advantages and disadvantages of each refrigerants and their suitability for window air conditioners.

Bansal, Pradeep [ORNL] [ORNL; Shen, Bo [ORNL] [ORNL

2014-01-01T23:59:59.000Z

186

ARTI Refrigerant Database  

SciTech Connect (OSTI)

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

1994-05-27T23:59:59.000Z

187

Plant Site Refrigeration Upgrade  

E-Print Network [OSTI]

Bayer Corporation operates a multi-division manufacturing facility in Bushy Park, South Carolina. Low temperature refrigeration (-4°F) is required by many of the chemical manufacturing areas and is provided by a Plant Site Refrigeration System...

Zdrojewski, R.; Healy, M.; Ramsey, J.

188

Save with Hybrid Refrigeration  

E-Print Network [OSTI]

SAVE WITH HYBRID REFRIGERATION Cheng-Wen (Wayne) Chung, P.E. Fluor Engineers, Inc. Irvine, California ABSTRACT Two level demand makes it possible to use two systems for refrigeration and save energy and money. An example of this type... of refrigeration, consisting of an ammonia absorption refrigeration (AAR) unit and a mechanical compression refrigera tion (MCR) unit, is presented in this article. This paper will briefly describe process configur ation, advantages and utility consumption...

Chung, C. W.

189

Residential Mail Procedures Residential Mail Services  

E-Print Network [OSTI]

Residential Mail Procedures Residential Mail Services 23 Owens Hall Blacksburg, VA 24061 Phone.mailservices.vt.edu #12;Residential Mail Procedures Table of Contents General information.................................................................................8 #12;Residential Mail Procedures The following procedures have been establishes by the University

Buehrer, R. Michael

190

1991 & 1992 trade-in refrigerator metering project  

SciTech Connect (OSTI)

Under SMUD`s Equipment Efficiency Improvement Program the District offers an incentive of $100 to customers who trade in an older refrigerator in conjunction with the purchase of a new model. More than 40,000 refrigerators have been traded in this program as of January 1993. This program has provided 36.5% of the total reported savings from all SMUD`s conservation programs through April 1993. Of this 36.5% reported savings, 84.7% is attributed to the trading in of an old refrigerator for a new model, and only 15.3% to purchases of a new refrigerators without trading in their older model. In 1992 two laboratory studies were undertaken to quantify energy use of older, close to retirement, domestic residential refrigerators from participants in SMUD`s refrigerator trade-in program. One study focused on annual energy use from older model refrigerators received from this program, and the second study focused on potential energy savings from condenser coil cleaning from this same stock of refrigerators. To determine the performance of these refrigerators, a sample of 79 units was randomly selected for testing. Each unit was tested to obtain annual energy use (kWh/yr) and to document physical and operational conditions. A subset of 28 units from this sample was also tested to determine energy savings as a result of cleaning condenser coils. This was done by comparing test results of annual energy use before and after coil cleaning. These refrigerators were tested to the same conventional procedures (commonly called the {open_quotes}DOE{close_quotes} test, or AHAM test procedures) used to arrive at annual energy use labeled on all new refrigerators. Although laboratory results do not exactly replicate field (in-home) results, they have been found to still be a reasonably good predictor of energy use as reported in a Lawrence Berkeley Laboratory study , discussed in the following section.

Bos, W.

1994-12-31T23:59:59.000Z

191

Laboratory Safety Survey Chemical Hygiene Plan  

E-Print Network [OSTI]

. Are refrigerators/freezers used for storage of flammables non-sparking (laboratory safe) and properly labeled? 26 in the lab and kept out of the laboratory refrigerators or cabinets? 16. Are fire extinguishers accessible. Are non-spark-proof refrigerators (household-type) labeled as "Unsafe for Flammable Storage"? 27. Are all

Ferrara, Katherine W.

192

LAB INSPECTION CHECK LIST Building: Room: Inspection Date: Time  

E-Print Network [OSTI]

Notes 4. Are biohazard warnings on freezers, refrigerators and storage units where biological materials are present? OSHA Biohazard warning labels must be posted on all refrigerators, freezers, and storage units. Is "No Food" sign posted on lab microwaves; "No food and No Flammables" sign posted on lab refrigerators

Weber, Rodney

193

(Created 1/01; Revised 5/05, 3/08) UNL Environmental Health and Safety (402) 472-4925 http://ehs.unl.edu  

E-Print Network [OSTI]

Refrigerators and Freezers ­ Store flammable liquids requiring cooling in tightly closed containers within refrigerators and/or freezers that meet specific design criteria, including no internal ignition sources. Manufacturers of flammable liquid refrigerators/freezers must prominently mark these types of devices

Farritor, Shane

194

ARTI refrigerant database  

SciTech Connect (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates. Citations in this report are divided into the following topics: thermophysical properties; materials compatibility; lubricants and tribology; application data; safety; test and analysis methods; impacts; regulatory actions; substitute refrigerants; identification; absorption and adsorption; research programs; and miscellaneous documents. Information is also presented on ordering instructions for the computerized version.

Calm, J.M. [Calm (James M.), Great Falls, VA (United States)] [Calm (James M.), Great Falls, VA (United States)

1996-04-15T23:59:59.000Z

195

China Refrigerator Information Label  

E-Print Network [OSTI]

LBNL-246E China Refrigerator Information Label: Specification Development and Potential Impact Jianhong Cheng China National Institute of Standardization Tomoyuki Sakamoto The Institute of Energy

196

ARTI refrigerant database  

SciTech Connect (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufactures and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on many refrigerants including propane, ammonia, water, carbon dioxide, propylene, ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

1998-08-01T23:59:59.000Z

197

Manufacture of refrigeration oils  

SciTech Connect (OSTI)

Lubricating oils suitable for use in refrigeration equipment in admixture with fluorinated hydrocarbon refrigerants are produced by solvent extraction of naphthenic lubricating oil base stocks, cooling the resulting extract mixture, optionally with the addition of a solvent modifier, to form a secondary raffinate and a secondary extract, and recovering a dewaxed oil fraction of lowered pour point from the secondary raffinate as a refrigeration oil product. The process of the invention obviates the need for a separate dewaxing operation, such as dewaxing with urea, as conventionally employed for the production of refrigeration oils.

Chesluk, R.P.; Platte, H.J.; Sequeira, A.J.

1981-12-08T23:59:59.000Z

198

Small Commercial Refrigeration Incentive  

Broader source: Energy.gov [DOE]

Efficiency Vermont offers financial incentives to cover the incremental costs of energy efficient refrigeration for commercial, industrial, agricultural and institutional buildings. To receive the...

199

ARTI refrigerant database  

SciTech Connect (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alterative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on various refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

Calm, J.M.

1997-02-01T23:59:59.000Z

200

Chemically assisted mechanical refrigeration process  

DOE Patents [OSTI]

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.

Vobach, A.R.

1987-11-24T23:59:59.000Z

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Chemically assisted mechanical refrigeration process  

DOE Patents [OSTI]

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.

Vobach, A.R.

1987-06-23T23:59:59.000Z

202

Thermophysical properties of stainless steel foils  

SciTech Connect (OSTI)

Evacuated panel superinsulations with very high center-of-panel thermal resistances are being developed for use in refrigerators/freezers. Attainment of high resistances relies upon the maintenance of low vacuum levels by the use of stainless steel vacuum jackets. However, the metal jackets also present a path for heat conduction around the high resistance fillers. This paper presents results of a study of the impact of metal vacuum jackets on the overall thermal performance of vacuum superinsulations when incorporated into the walls and doors of refrigerators/freezers. Results are presented on measurements of the thermophysical properties of several types and thicknesses of stainless steel foils that were being considered for application in superinsulations. A direct electrical heating method was used for simultaneous measurements of the electrical resistivity, total hemispherical emittance, and thermal conductivity of the foils. Results are also presented on simulations of the energy usage of refrigerators/freezers containing stainless-steel-clad vacuum superinsulations.

Wilkes, K.E.; Strizak, J.P.; Weaver, F.J. [Oak Ridge National Lab., TN (United States); Besser, J.E.; Smith, D.L. [Aladdin Industries, Inc. (United States)

1997-10-01T23:59:59.000Z

203

ARTI Refrigerant Database  

SciTech Connect (OSTI)

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on R-32, R-123, R-124, R- 125, R-134a, R-141b, R142b, R-143a, R-152a, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses polyalkylene glycol (PAG), ester, and other lubricants. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits.

Calm, J.M.

1992-04-30T23:59:59.000Z

204

Residential Buildings  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2007 10,998 9,933 10,998 10,643 10,998throughThousand CubicWashington Natural GasResidential Residential

205

Supplement to: March 1982 consumer products efficiency standards, engineering analysis and economic analysis documents  

SciTech Connect (OSTI)

The following product types are discussed: refrigerators and refrigerator freezers, freezers, furnaces and boilers, and central air conditioners. Some topics included are: hybrid evaporators, cost efficiency relationships, high-efficiency compressor substitution, pulsed combustion, all aluminium heat exchanger, and high-efficiency two-speed compressor.

Not Available

1983-07-01T23:59:59.000Z

206

851 S.W. Sixth Avenue, Suite 1100 Steve Crow 503-222-5161 Portland, Oregon 97204-1348 Executive Director 800-452-5161  

E-Print Network [OSTI]

of 2011 DOE is scheduled to issue final standards for water heaters, refrigerators, freezers, central air minimum efficiency standards for appliances. NAECA not only establish federal minimum standards for water heaters, clothes washers, refrigerators and other appliances, it set a schedule for the DOE to follow

207

Stirling-cycle refrigerator  

SciTech Connect (OSTI)

A Stirling-cycle refrigerator comprises a plurality of Stirling-cycle refrigerator units each having a displacer defining an expansion chamber, a piston defining a compression chamber, and a circuit including a heater and a cooler and interconnecting the expansion chamber and the compression chamber, and a heat exchanger shared by the circuits and disposed between the coolers and the heaters for effecting heat exchange between working gases in the circuits. The heat exchanger may comprise a countercurrent heat exchanger, and the Stirling-cycle refrigerator units are operated in cycles which are 180/sup 0/ out of phase with each other.

Nakamura, K.

1985-06-11T23:59:59.000Z

208

International Refrigeration: Order (2012-CE-1510) | Department...  

Broader source: Energy.gov (indexed) [DOE]

Refrigeration: Order (2012-CE-1510) July 20, 2012 DOE ordered International Refrigeration Products to pay an 8,000 civil penalty after finding International Refrigeration had...

209

Thermoacoustic engines and refrigerators  

SciTech Connect (OSTI)

This report is a transcript of a practice lecture given in preparation for a review lecture on the operation of thermoacoustic engines and refrigerators. The author begins by a brief review of the thermodynamic principles underlying the operation of thermoacoustic engines and refrigerators. Remember from thermodynamics class that there are two kinds of heat engines, the heat engine or the prime mover which produces work from heat, and the refrigerator or heat pump that uses work to pump heat. The device operates between two thermal reservoirs at temperatures T{sub hot} and T{sub cold}. In the heat engine, heat flows into the device from the reservoir at T{sub hot}, produces work, and delivers waste heat into the reservoir at T{sub cold}. In the refrigerator, work flows into the device, lifting heat Q{sub cold} from reservoir at T{sub cold} and rejecting waste heat into the reservoir at T{sub hot}.

Swift, G.

1996-12-31T23:59:59.000Z

210

Refrigerants in Transition  

E-Print Network [OSTI]

.E. Senior Engineer The Hartford Steam Boiler Inspection and Insurance Company Hartford,. Connecticut ABSTRACT The massive growth of air conditioning and refrigeration has been a direct result of the development of a class of chemicals called fluorocarbons..., Gordon, "Forty Years Research on Atmospheric Ozone at Oxford: A !Iistory," Applied Optics, March t968, pp. 387-405. 4. Downing, R., "Development of Chloro fluorocarbon Refrigerants," CFCs: Time of Transition, ASHRAE Publication, Atlanta, GA, 1989...

Stouppe, D. E.

211

Residential Services Headlease residents  

E-Print Network [OSTI]

Residential Services Headlease residents handbook 2013-2014 #12;Map of Brighton inside front cover packs Rent 5 Residential Advisor (RA) network 6 Senior residential advisors Residential Student Support Contents Contents Brighton 1 #12;Welcome Congratulations on securing your place at Sussex. Residential

Sussex, University of

212

Residential Solar Valuation Rates  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Residential Solar Valuation Rates Karl R. Rbago Rbago Energy LLC 1 The Ideal Residential Solar Tariff Fair to the utility and non-solar customers Fair compensation to...

213

Downhole pulse tube refrigerators  

SciTech Connect (OSTI)

This report summarizes a preliminary design study to explore the plausibility of using pulse tube refrigeration to cool instruments in a hot down-hole environment. The original motivation was to maintain Dave Reagor`s high-temperature superconducting electronics at 75 K, but the study has evolved to include three target design criteria: cooling at 30 C in a 300 C environment, cooling at 75 K in a 50 C environment, cooling at both 75 K and 30 C in a 250 C environment. These specific temperatures were chosen arbitrarily, as representative of what is possible. The primary goals are low cost, reliability, and small package diameter. Pulse-tube refrigeration is a rapidly growing sub-field of cryogenic refrigeration. The pulse tube refrigerator has recently become the simplest, cheapest, most rugged and reliable low-power cryocooler. The authors expect this technology will be applicable downhole because of the ratio of hot to cold temperatures (in absolute units, such as Kelvin) of interest in deep drilling is comparable to the ratios routinely achieved with cryogenic pulse-tube refrigerators.

Swift, G.; Gardner, D. [Los Alamos National Lab., NM (United States). Condensed Matter and Thermal Physics Group

1997-12-01T23:59:59.000Z

214

ARTI Refrigerant Database  

SciTech Connect (OSTI)

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents to accelerate availability of the information and will be completed or replaced in future updates.

Cain, J.M. (Calm (James M.), Great Falls, VA (United States))

1993-04-30T23:59:59.000Z

215

Proceedings: Commercial Refrigeration Research Workshop  

SciTech Connect (OSTI)

Improving refrigeration systems for commercial use can enhance both utility load factors and supermarket profits. This workshop has pinpointed research needs in commercial refrigeration and systems integration for a supermarket environment.

None

1984-10-01T23:59:59.000Z

216

Waste Heat Recovery from Refrigeration  

E-Print Network [OSTI]

heat recovery from refrigeration machines is a concept which has great potential for implementation in many businesses. If a parallel requirement for refrigeration and hot water exists, the installation of a system to provide hot water as a by...

Jackson, H. Z.

1982-01-01T23:59:59.000Z

217

Refrigeration monitor and alarm system  

SciTech Connect (OSTI)

A monitor is described for a refrigeration system including a heat reclaiming system coupled therewith, comprising: a sensor positioned to detect the level of liquid state refrigerant in the system and provide an electrical output signal therefrom; a digital display for displaying the refrigerant level; first circuit means coupling the digital display to the sensor for actuating the digital display; and lockout means coupled with the sensor for deactivating the heat reclaiming system when a preselected refrigerant level is reached.

Branz, M.A.; Renaud, P.F.

1986-09-23T23:59:59.000Z

218

Ames Lab 101: Magnetic Refrigeration  

ScienceCinema (OSTI)

Vitalij Pecharsky, distinguished professor of materials science and engineering, discusses his research in magnetic refrigeration at Ames Lab.

Pecharsky, Vitalij

2013-03-01T23:59:59.000Z

219

ARTI Refrigerant Database  

SciTech Connect (OSTI)

The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R- 717 (ammonia), ethers, and others as well as azeotropic and zeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents on compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. A computerized version is available that includes retrieval software.

Calm, J.M.

1992-11-09T23:59:59.000Z

220

Refrigerator recycling and CFCs  

SciTech Connect (OSTI)

Utility-sponsored refrigerator and freezer pick-up programs have removed almost 900,000 inefficient appliances from the North American electric grid to date. While the CFC-12 refrigerant from the discarded appliances is typically removed and recycled, in all but a few programs the CFC-11 in the foam insulation is not. About a quarter-billion pounds of CFC-11 are banked in refrigerator foam in the United States. Release of this ``bank`` of CFC, combined with that from foam insulation used in buildings, will be the largest source of future emissions if preventive measures are not taken. Methods exist to recover the CFC for reuse or to destroy it by incineration. The task of recycling or destroying the CFCs and other materials from millions of refrigerators is a daunting challenge, but one in which utilities can play a leadership role. E Source believes that utilities can profitably serve as the catalyst for public-private partnerships that deliver comprehensive refrigerator recycling. Rather than treating such efforts solely as a DSM resource acquisition, utilities could position these programs as a multifaceted service delivery that offers convenient appliance removal for homeowners, a solid waste minimization service for landfills, a source of recycled materials for industry, and a CFC recovery and/or disposal service in support of the HVAC industry and society`s atmospheric protection goals and laws. Financial mechanisms could be developed through these public-private enterprises to ensure that utilities are compensated for the extra cost of fully recycling refrigerators, including the foam CFC.

Shepard, M.; Hawthorne, W.; Wilson, A.

1994-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Low-temperature magnetic refrigerator  

DOE Patents [OSTI]

The invention relates to magnetic refrigeration and more particularly to low temperature refrigeration between about 4 and about 20 K, with an apparatus and method utilizing a belt of magnetic material passed in and out of a magnetic field with heat exchangers within and outside the field operably disposed to accomplish refrigeration.

Barclay, J.A.

1983-05-26T23:59:59.000Z

222

Helium dilution refrigeration  

E-Print Network [OSTI]

. 1875" OD exchanger Qu ID copper cap Fig. 6. Assembled view of 3He - He dilution refrigerator. 26 The joint thru the tubing wall and the joining of the two sizes of capillary were silver soldered (35/ silver content). A 0. 250" OD tube... the inert atmosphere inside the refrigerator. After removal from the nitrogen atmosphere the graphite support, was 'attached to the still and mixing chamber using Stycast 2850 GT with catalyst g9 ). The mass of the graphite 26 support 1s 11. 62 grams...

McKee, Thomas Raymond

2012-06-07T23:59:59.000Z

223

Enhanced naphthenic refrigeration oils for household refrigerator systems  

SciTech Connect (OSTI)

Due to industry concerns about the successful employment of hydrofluorocarbon-immiscible hydrocarbon oils in refrigeration systems, enhanced naphthenic refrigeration oils have been developed. These products have been designed to be more dispersible with hydrofluorocarbon (HFC) refrigerants, such as R-134a, in order to facilitate lubricant return to the compressor and to ensure proper energy efficiency of the system. Bench tests and system performance evaluations indicate the feasibility of these oils for use in household refrigeration applications. Results of these evaluations are compared with those obtained with polyol esters and typical naphthenic mineral oils employed in chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigeration applications.

Reyes-Gavilan, J.L.; Flak, G.T.; Tritcak, T.R. [Witco Corp., Oakland, NJ (United States); Barbour, C.B. [Americold, Cullman, AL (United States)

1997-12-31T23:59:59.000Z

224

Using National Survey Data to Estimate Lifetimes of Residential Appliances  

E-Print Network [OSTI]

conditioners (RACs), refrigerators, and freezers. GENERALsection). Refrigerators and Freezers Refrigerators followDifference* this Study Freezer Refrigerator Water Heater,

Lutz, James D.

2013-01-01T23:59:59.000Z

225

Residential Learning University Housing  

E-Print Network [OSTI]

Residential Learning & University Housing Handbook 2008 - 2009 A Guide for Residential Living on the Campus of Rowan University #12;Welcome to Residential Learning & University Housing! The primary purpose of the Office of Residential Life & University Housing is to assist and support students in the pursuit

Rusu, Adrian

226

Residential Colleges NORTHWESTERN  

E-Print Network [OSTI]

Residential Colleges NORTHWESTERN #12;#12;Dear Northwestern Student: I hope you will review residential colleges. A residential college is a place where you can grow emotionally and intellectually, get and residential college fellows. More than a third of the first-year students living on campus choose to live

Shull, Kenneth R.

227

RESIDENTIAL COLLEGES NORTHWESTERN  

E-Print Network [OSTI]

c RESIDENTIAL COLLEGES NORTHWESTERN #12;#12;Dear Northwestern Student: I hope you will review residential colleges. A residential college is a place where you can grow emotionally and intellectually, get and residential college fellows. More than a third of the first-year students living on campus choose to live

Apkarian, A. Vania

228

Comparison of Several Eco-Friendly Refrigeration Technologies  

E-Print Network [OSTI]

In this paper, the operation principles, thermodynamics characteristics, and technical practicability were compared between thermoelectric refrigeration, magnetic refrigeration and adsorption refrigeration. The TE refrigeration is the most well...

Tang, C.; Luo, Q.; Li, X.; Zhu, X.

2006-01-01T23:59:59.000Z

229

Estimated United States Residential Energy Use in 2005  

SciTech Connect (OSTI)

A flow chart depicting energy flow in the residential sector of the United States economy in 2005 has been constructed from publicly available data and estimates of national energy use patterns. Approximately 11,000 trillion British Thermal Units (trBTUs) of electricity and fuels were used throughout the United States residential sector in lighting, electronics, air conditioning, space heating, water heating, washing appliances, cooking appliances, refrigerators, and other appliances. The residential sector is powered mainly by electricity and natural gas. Other fuels used include petroleum products (fuel oil, liquefied petroleum gas and kerosene), biomass (wood), and on-premises solar, wind, and geothermal energy. The flow patterns represent a comprehensive systems view of energy used within the residential sector.

Smith, C A; Johnson, D M; Simon, A J; Belles, R D

2011-12-12T23:59:59.000Z

230

Asset Management Equipment Disposal Form -Refrigerant Recovery  

E-Print Network [OSTI]

enters the waste stream with the charge intact (e.g., motor vehicle air conditioners, refrigeratorsAsset Management Equipment Disposal Form - Refrigerant Recovery Safe Disposal Requirements Under refrigeration, cold storage warehouse refrigeration, chillers, and industrial process refrigeration) has to have

Sin, Peter

231

Parent Orientation: Day 2 Overview Housing and Dining Services  

E-Print Network [OSTI]

Convenience Stores 1 Bakery 1 Restaurant #12;Allergen Project · Sample Food Labels Special Dietary Needs, desk lamp, dresser, and closet space (note: buy extra-long single sheets for the bed!) · Microwave/refrigerator/freezer · High-speed data access is available in all residence hall rooms #12;What Not to Bring (sample)* Hot

Stowell, Michael

232

LG Electronics U.S.A. v. DOE, Stipulation of Voluntary Dismissal  

Broader source: Energy.gov [DOE]

LG Electronics U.S.A., Inc. v. U.S. Dept. of Energy, Civil Action Number 1:09-cv-02297-JDB - LG voluntarily dismissed its claims against the DOE and agrees to remove the ENERGY STAR labels from various refrigerator-freezers.

233

UCHC Competency Checklist: ANNUAL Position Title:Nursing Care Associate Employee Name: Unit: _______  

E-Print Network [OSTI]

: CLUSTER SPECIFIC COMPETENCIES 1. Reports to charge nurse at the beginning of shift for assignment and daily checklist 2. Completes the daily checklist; communicates with charge nurse regarding unfinished. 4. Documents follow up to out of range refrigerator, freezer, and warmer temperatures. 5. Docks

Oliver, Douglas L.

234

Home > Visit apartments online > Vacation Rental > Bailleul I own an Apartment  

E-Print Network [OSTI]

with baker, wine shop, pharmacy and small bars and bistrots with a FRANPRIX supermarket nearby and security description: - 1890 Building, 4 floor, with lift, entry code security system, with interphone, 2 Bedrooms Apt clean. - Dishwasher, Refrigerator, Freezer, Cooking rings, Oven, Microwave, Dinnerware and serving

Gray, Robert M.

235

Home > Visit apartments online > Vacation Rental > Bailleul I own an Apartment  

E-Print Network [OSTI]

Paris ambience with baker, wine shop, pharmacy and small bars and bistrots with a FRANPRIX supermarket floor, entry code security system, with interphone, 2 Bedrooms Apt, furnished, 66m / 660 sqft, high. - Dishwasher, Refrigerator, Freezer, Cooking rings, Oven, Microwave, Dinnerware and serving pieces, Toaster

Gray, Robert M.

236

Superefficient Refrigerators: Opportunities and Challenges for Efficiency Improvement Globally  

SciTech Connect (OSTI)

As an energy-intensive mainstream product, residential refrigerators present a significant opportunity to reduce electricity consumption through energy efficiency improvements. Refrigerators expend a considerable amount of electricity during normal use, typically consuming between 100 to 1,000 kWh of electricity per annum. This paper presents the results of a technical analysis done for refrigerators in support of the Super-efficient Equipment and Appliance Deployment (SEAD) initiative. Beginning from a base case representative of the average unit sold in India, we analyze efficiency improvement options and their corresponding costs to build a cost-versus-efficiency relationship. We then consider design improvement options that are known to be the most cost effective and that can improve efficiency given current design configurations. We also analyze and present additional super-efficient options, such as vacuum-insulated panels. We estimate the cost of conserved electricity for the various options, allowing flexible program design for market transformation programs toward higher efficiency. We estimate ~;;160TWh/year of energy savings are cost effective in 2030, indicating significant potential for efficiency improvement in refrigerators in SEAD economies and China.

Shah, Nihar; Park, Won Young; Bojda, Nicholas; McNeil, Michael A.

2014-08-01T23:59:59.000Z

237

Superfluid thermodynamic cycle refrigerator  

DOE Patents [OSTI]

A cryogenic refrigerator cools a heat source by cyclically concentrating and diluting the amount of .sup.3 He in a single phase .sup.3 He-.sup.4 He solution. The .sup.3 He in superfluid .sup.4 He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid .sup.3 He at an initial concentration in superfluid .sup.4 He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of .sup.4 He while restricting passage of .sup.3 He. The .sup.3 He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

Swift, Gregory W. (Santa Fe, NM); Kotsubo, Vincent Y. (La Canada, CA)

1992-01-01T23:59:59.000Z

238

Superfluid thermodynamic cycle refrigerator  

DOE Patents [OSTI]

A cryogenic refrigerator cools a heat source by cyclically concentrating and diluting the amount of [sup 3]He in a single phase [sup 3]He-[sup 4]He solution. The [sup 3]He in superfluid [sup 4]He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid [sup 3]He at an initial concentration in superfluid [sup 4]He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of [sup 4]He while restricting passage of [sup 3]He. The [sup 3]He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K. 12 figs.

Swift, G.W.; Kotsubo, V.Y.

1992-12-22T23:59:59.000Z

239

Compact acoustic refrigerator  

DOE Patents [OSTI]

A compact acoustic refrigeration system actively cools components, e.g., electrical circuits, in a borehole environment. An acoustic engine includes first thermodynamic elements for generating a standing acoustic wave in a selected medium. An acoustic refrigerator includes second thermodynamic elements located in the standing wave for generating a relatively cold temperature at a first end of the second thermodynamic elements and a relatively hot temperature at a second end of the second thermodynamic elements. A resonator volume cooperates with the first and second thermodynamic elements to support the standing wave. To accommodate the high heat fluxes required for heat transfer to/from the first and second thermodynamic elements, first heat pipes transfer heat from the heat load to the second thermodynamic elements and second heat pipes transfer heat from first and second thermodynamic elements to the borehole environment. 18 figs.

Bennett, G.A.

1992-11-24T23:59:59.000Z

240

Compact acoustic refrigerator  

DOE Patents [OSTI]

A compact acoustic refrigeration system actively cools components, e.g., electrical circuits (22), in a borehole environment. An acoustic engine (12, 14) includes first thermodynamic elements (12) for generating a standing acoustic wave in a selected medium. An acoustic refrigerator (16, 26, 28) includes second thermodynamic elements (16) located in the standing wave for generating a relatively cold temperature at a first end of the second thermodynamic elements (16) and a relatively hot temperature at a second end of the second thermodynamic elements (16). A resonator volume (18) cooperates with the first and second thermodynamic elements (12, 16) to support the standing wave. To accommodate the high heat fluxes required for heat transfer to/from the first and second thermodynamic elements (12, 16), first heat pipes (24, 26) transfer heat from the heat load (22) to the second thermodynamic elements (16) and second heat pipes (28, 32) transfer heat from first and second thermodynamic elements (12, 16) to the borehole environment.

Bennett, Gloria A. (Los Alamos, NM)

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Multilayer Thermionic Refrigeration  

SciTech Connect (OSTI)

A review is presented of our program to construct an efficient solid state refrigerator based on thermionic emission of electrons over periodic barriers in the solid. The experimental program is to construct a simple device with one barrier layer using a three layers: metal-semiconductor-metal. The theoretical program is doing calculations to determine: (i) the optimal layer thickness, and (ii) the thermal conductivity.

Mahan, G.D.

1999-08-30T23:59:59.000Z

242

Vaccine refrigerator testing. Final report  

SciTech Connect (OSTI)

For the Central American Health Clinic Project initiated in 1986, Sandia National Laboratories and the Florida Solar Energy Center recognized the need for a test and evaluation program for vaccine refrigeration systems. At the Florida Solar Energy Center, side-by-side testing of three photovoltaic powered vaccine refrigerators began in 1987. The testing was expanded in 1988 to include a kerosene absorption refrigerator. This report presents observations, conclusions, and recommendations derived from testing the four vaccine refrigeration systems. Information is presented pertaining to the refrigerators, photovoltaic arrays, battery subsystems, charge controllers, and user requirements. This report should be of interest to designers, manufacturers, installers, and users of photovoltaic-powered vaccine refrigeration systems and components.

Ventre, G.G. [Univ. of Central Florida, Orlando, FL (United States); Kilfoyle, D.; Marion, B. [Florida Solar Energy Center, Cape Canaveral, FL (United States)

1990-06-01T23:59:59.000Z

243

Covered Product Category: Residential Refrigerators | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top FiveDepartmentfor EngineeringDepartment

244

One of the limitations of using refrigerant mixtures to achieve capacity modulation is that the range of capacity control and the temperature glide are both functions of the difference  

E-Print Network [OSTI]

for an air-source system because the test rig was equipped with water-to-refrigerant heat exchangers points of the two pure components. For applications in residential heat pumps, the temperature glide on a residential heat pump application, it was desirable to test at conditions similar to those found

Oak Ridge National Laboratory

245

NICE3: Industrial Refrigeration System  

SciTech Connect (OSTI)

Energy Concepts has developed an absorption-augmented system as a cost-effective means of achieving more cooling capacity with a substantial reduction in energy consumption and greenhouse gas emissions for industrial refrigeration. It cuts fuel consumption by 30% by combining an internal combustion engine with a mechanical compression refrigeration system and an absorption refrigeration system. The absorption system is powered by engine waste heat. Conventional industrial refrigeration uses mechanical vapor compression, powered by electric motors, which results in higher energy costs. By the year 2010, the new system could cut fuel consumption by 19 trillion Btu and greenhouse emissions by more than 1 million tons per year.

Simon, P.

1999-09-29T23:59:59.000Z

246

Residential Energy Audits  

E-Print Network [OSTI]

A series of events coupled with the last five years experience performing Residential Conservation Service (RCS) audits have resulted in renewed efforts by utilities to evaluate the role of residential energy audits. There are utilities where...

Brown, W.

1985-01-01T23:59:59.000Z

247

New Energy Efficiency Standards for Commercial Refrigeration...  

Office of Environmental Management (EM)

for Commercial Refrigeration Equipment to Cut Businesses' Energy Bills and Carbon Pollution New Energy Efficiency Standards for Commercial Refrigeration Equipment to Cut...

248

Case Study: Transcritical Carbon Dioxide Supermarket Refrigeration...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Case Study: Transcritical Carbon Dioxide Supermarket Refrigeration Systems Case Study: Transcritical Carbon Dioxide Supermarket Refrigeration Systems This case study documents one...

249

Guide for Benchmarking Residential Energy Efficiency Program...  

Energy Savers [EERE]

Guide for Benchmarking Residential Energy Efficiency Program Progress Guide for Benchmarking Residential Energy Efficiency Program Progress Guide for Benchmarking Residential...

250

Better Buildings Residential Program Solution Center Demonstration...  

Energy Savers [EERE]

Better Buildings Residential Program Solution Center Demonstration Better Buildings Residential Program Solution Center Demonstration Better Buildings Residential Program Solution...

251

Presentation: Better Buildings Residential Program Solution Center...  

Energy Savers [EERE]

Presentation: Better Buildings Residential Program Solution Center Presentation: Better Buildings Residential Program Solution Center Presentation: Better Buildings Residential...

252

Membership Criteria: Better Buildings Residential Network | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Membership Criteria: Better Buildings Residential Network Membership Criteria: Better Buildings Residential Network Membership Criteria: Better Buildings Residential Network...

253

Comfort by Design: An Introduction to HVAC's Variable Refrigerant Flow (VRF) Technology  

E-Print Network [OSTI]

Comfort by Design An Introduction to HVAC’s Variable Refrigerant Flow (VRF) Technology Keith Reihl kreihl@hvac.mea.com ESL-KT-14-11-13 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 HVAC Market Overview 0% 27% 9% 5% 4... Through Efficiency Conference, Dallas, Texas Nov. 18-20 How LOUD is a traditional HVAC unit? 33 dB(A) Library 50 dB(A) Refrigerator 60 dB(A) Conversation 78 dB(A) Vacuum 25 dB(A) Recording Studio 65-75 dB(A) Residential 3-ton HVAC Unit How Q IET are VRF...

Reihl,K.

2014-01-01T23:59:59.000Z

254

Housing and Residential Life  

E-Print Network [OSTI]

1 Housing and Residential Life Guidebook 2014-2015 LivingCampus #12;2 fau.edu/housing Welcome! The Housing & Residential Life staff is excited that you've moved home! Florida Atlantic University residence halls and apartments are your home for the 2014-2015 school year. The Housing & Residential Life staff

Fernandez, Eduardo

255

PROPOSED RESIDENTIAL ALTERNATIVE CALCULATION  

E-Print Network [OSTI]

PROPOSED RESIDENTIAL ALTERNATIVE CALCULATION MANUAL (ACM) APPROVAL METHOD for the 2013 2012 CEC400201200715DAY #12;201308 Residential ACM Approval Manual 2-2 1. Overview Minimum Modeling Capabilities 1. Overview This Manual explains the requirements for approval of residential Alternative

256

AREA COORDINATOR RESIDENTIAL EDUCATION  

E-Print Network [OSTI]

AREA COORDINATOR RESIDENTIAL EDUCATION VANDERBILT UNIVERSITY, NASHVILLE, TENNESSEE The Office of Housing and Residential Education at Vanderbilt University is seeking applicants for an Area Coordinator. The Area Coordinator is responsible for assisting in the management and operation of a residential area

Bordenstein, Seth

257

Residential Wood Residential wood combustion (RWC) is  

E-Print Network [OSTI]

Residential Wood Combustion Residential wood combustion (RWC) is increasing in Europe because PM2.5. Furthermore, other combustion- related sources of OA in Europe may need to be reassessed. Will it affect global OA emission estimates? Combustion of biofuels is globally one of the major OA sources

258

Developing cost curves for conserved energy in new refrigerators and freezers: Demonstration of methodology and detailed engineering results  

SciTech Connect (OSTI)

This paper develops and demonstrates a procedure for determining the cost of conserved energy in residential refrigerators and freezers and for ranking conservation measures according to economic feasibility and practicality. Prepared jointly by the Natural Resources Defense Council and ACEE for the Solar Energy Research Institute.

Goldstein, D.; Miller, P.; Watson, R.

1987-01-01T23:59:59.000Z

259

The refrigerator revolution  

SciTech Connect (OSTI)

This article discusses how a simple, new technology threw the best-laid plans of the chemical and refrigerator industries into disarray-and provided a new perspective on how future environmental agreements can be reached. In recent years, a series of massive business mergers has mesmerized the industrial world. However in the early 1990s a German environmentalist, triggered global reprocussions in the wake of the mandate to phase out the use of ozone depleting substances. The economic and political background of this is explained in detail.

Ayres, E.; French, H.

1996-09-01T23:59:59.000Z

260

COLD STORAGE DESIGN REFRIGERATION EQUIPMENT  

E-Print Network [OSTI]

COLD STORAGE DESIGN AND REFRIGERATION EQUIPMENT REFRIGERATION OF FISH - PART 1 \\ "..\\- ,,, T I (Section 1), and F. Bruce Sanford (Section 1) Table of Contents Pages Section 1 - Cold Storage Design to be Considered in the Freezing and Cold Storage of Fishery Products - Preparing, Freezing, and Cold Storage

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Load Forecasting of Supermarket Refrigeration  

E-Print Network [OSTI]

energy system. Observed refrigeration load and local ambient temperature from a Danish su- permarket renewable energy, is increasing, therefore a flexible energy system is needed. In the present ThesisLoad Forecasting of Supermarket Refrigeration Lisa Buth Rasmussen Kongens Lyngby 2013 M.Sc.-2013

262

Final Scientific/Technical Report for DOE/EERE project Advanced Magnetic Refrigerant Materials  

SciTech Connect (OSTI)

A team led by GE Global Research developed new magnetic refrigerant materials needed to enhance the commercialization potential of residential appliances such as refrigerators and air conditioners based on the magnetocaloric effect (a nonvapor compression cooling cycle). The new magnetic refrigerant materials have potentially better performance at lower cost than existing materials, increasing technology readiness level. The performance target of the new magnetocaloric material was to reduce the magnetic field needed to achieve 4 °C adiabatic temperature change from 1.5 Tesla to 0.75 Tesla. Such a reduction in field minimizes the cost of the magnet assembly needed for a magnetic refrigerator. Such a reduction in magnet assembly cost is crucial to achieving commercialization of magnetic refrigerator technology. This project was organized as an iterative alloy development effort with a parallel material modeling task being performed at George Washington University. Four families of novel magnetocaloric alloys were identified, screened, and assessed for their performance potential in a magnetic refrigeration cycle. Compositions from three of the alloy families were manufactured into regenerator components. At the beginning of the project a previously studied magnetocaloric alloy was selected for manufacturing into the first regenerator component. Each of the regenerators was tested in magnetic refrigerator prototypes at a subcontractor at at GE Appliances. The property targets for operating temperature range, operating temperature control, magnetic field sensitivity, and corrosion resistance were met. The targets for adiabatic temperature change and thermal hysteresis were not met. The high thermal hysteresis also prevented the regenerator components from displaying measurable cooling power when tested in prototype magnetic refrigerators. Magnetic refrigerant alloy compositions that were predicted to have low hysteresis were not attainable with conventional alloy processing methods. Preliminary experiments with rapid solidification methods showed a path towards attaining low hysteresis compositions should this alloy development effort be continued.

Johnson, Francis

2014-06-30T23:59:59.000Z

263

Helium dilution refrigeration system  

DOE Patents [OSTI]

A helium dilution refrigeration system operable over a limited time period, and recyclable for a next period of operation. The refrigeration system is compact with a self-contained pumping system and heaters for operation of the system. A mixing chamber contains .sup.3 He and .sup.4 He liquids which are precooled by a coupled container containing .sup.3 He liquid, enabling the phase separation of a .sup.3 He rich liquid phase from a dilute .sup.3 He-.sup.4 He liquid phase which leads to the final stage of a dilution cooling process for obtaining low temperatures. The mixing chamber and a still are coupled by a fluid line and are maintained at substantially the same level with the still cross sectional area being smaller than that of the mixing chamber. This configuration provides maximum cooling power and efficiency by the cooling period ending when the .sup.3 He liquid is depleted from the mixing chamber with the mixing chamber nearly empty of liquid helium, thus avoiding unnecessary and inefficient cooling of a large amount of the dilute .sup.3 He-.sup.4 He liquid phase.

Roach, Patrick R. (Darien, IL); Gray, Kenneth E. (Naperville, IL)

1988-01-01T23:59:59.000Z

264

Helium dilution refrigeration system  

DOE Patents [OSTI]

A helium dilution refrigeration system operable over a limited time period, and recyclable for a next period of operation is disclosed. The refrigeration system is compact with a self-contained pumping system and heaters for operation of the system. A mixing chamber contains [sup 3]He and [sup 4]He liquids which are precooled by a coupled container containing [sup 3]He liquid, enabling the phase separation of a [sup 3]He rich liquid phase from a dilute [sup 3]He-[sup 4]He liquid phase which leads to the final stage of a dilution cooling process for obtaining low temperatures. The mixing chamber and a still are coupled by a fluid line and are maintained at substantially the same level with the still cross sectional area being smaller than that of the mixing chamber. This configuration provides maximum cooling power and efficiency by the cooling period ending when the [sup 3]He liquid is depleted from the mixing chamber with the mixing chamber nearly empty of liquid helium, thus avoiding unnecessary and inefficient cooling of a large amount of the dilute [sup 3]He-[sup 4]He liquid phase. 2 figs.

Roach, P.R.; Gray, K.E.

1988-09-13T23:59:59.000Z

265

DEPARTMENT OF RESIDENTIAL LIFE Residential Life Staff Manual.  

E-Print Network [OSTI]

1 Appendix A DEPARTMENT OF RESIDENTIAL LIFE Residential Life Staff Manual. Residential Life Program Listing #12;2 MISSOURI S&T RESIDENTIAL LIFE DEPARTMENT Staff Resource Manual 2010--2012 Department of Residential Life Mission: To create educational environments emphasizing learning and development. Service

Missouri-Rolla, University of

266

BNL Refrigerant Overview Presentation to the  

E-Print Network [OSTI]

charge. #12;BNL Refrigeration Management Plan Details how BNL complies with Sections 608 and 609BNL Refrigerant Overview Presentation to the BER and CAC Ed Murphy, PE Chief Engineer / Manager is a heating process. Refrigeration is an engineered "cycle" where the refrigerant is made to evaporate

Homes, Christopher C.

267

Cryogenic refrigeration apparatus  

DOE Patents [OSTI]

A technique for producing a cold environment in a refrigerant system in which input fluid from a compressor at a first temperature is introduced into an input channel of the system and is pre-cooled to a second temperature for supply to one of at least two stages of the system, and to a third temperature for supply to another stage thereof. The temperatures at such stages are reduced to fourth and fifth temperatures below the second and third temperatures, respectively. Fluid at the fourth temperature from the one stage is returned through the input channel to the compressor and fluid at the fifth temperature from the other stage is returned to the compressor through an output channel so that pre-cooling of the input fluid to the one stage occurs by regenerative cooling and counterflow cooling and pre-cooling of the input fluid to the other stage occurs primarily by counterflow cooling.

Crunkleton, James A. (Cambridge, MA)

1992-01-01T23:59:59.000Z

268

Cryogenic refrigeration apparatus  

DOE Patents [OSTI]

A technique for producing a cold environment in a refrigerant system in which input fluid from a compressor at a first temperature is introduced into an input channel of the system and is pre-cooled to a second temperature for supply to one of at least two stages of the system, and to a third temperature for supply to another stage thereof. The temperatures at such stages are reduced to fourth and fifth temperatures below the second and third temperatures, respectively. Fluid at the fourth temperature from the one stage is returned through the input channel to the compressor and fluid at the fifth temperature from the other stage is returned to the compressor through an output channel so that pre-cooling of the input fluid to the one stage occurs by regenerative cooling and counterflow cooling and pre-cooling of the input fluid to the other stage occurs primarily by counterflow cooling. 6 figs.

Crunkleton, J.A.

1992-03-31T23:59:59.000Z

269

The Quantum Absorption Refrigerator  

E-Print Network [OSTI]

A quantum absorption refrigerator driven by noise is studied with the purpose of determining the limitations of cooling to absolute zero. The model consists of a working medium coupled simultaneously to hot, cold and noise baths. Explicit expressions for the cooling power are obtained for Gaussian and Poisson white noise. The quantum model is consistent with the first and second laws of thermodynamics. The third law is quantified, the cooling power J_c vanishes as J_c proportional to T_c^{alpha}, when T_c approach 0, where alpha =d+1 for dissipation by emission and absorption of quanta described by a linear coupling to a thermal bosonic field, where d is the dimension of the bath.

Amikam Levy; Ronnie Kosloff

2011-11-09T23:59:59.000Z

270

Design of Industrial Process Refrigeration Systems  

E-Print Network [OSTI]

of the study is discussed in terms of identifying refrigeration intensive processes. Specific and general conclusions are presented to help faci I itate proper industrial refrigeration system design throughout fhe industry. This paper presents the resul ts... custaner's specifications. Most systems fall into two broad categories: Vapor Canpression Refrigeration Cycles - Mechanical or Steam Jet Canpression Systems Absorption Refrigeration Cycles - Heat Operated Cycles As shown in Table I, refrigerations...

Witherell, W. D.

271

China Refrigerator Information Label: Specification Development and Potential Impact  

E-Print Network [OSTI]

years. About 20% of refrigerators and freezers sold in 2000energy efficiency of refrigerators and freezers, Directiveof Energy, for refrigerators and freezers are base unit

Fridley, David

2008-01-01T23:59:59.000Z

272

Analysis of simultaneous cooling and heating in supermarket refrigeration systems.  

E-Print Network [OSTI]

?? In this master thesis project, conventional supermarket refrigeration systems using R404A are compared with refrigeration system solutions using natural refrigerants such as carbon dioxide… (more)

Marigny, Johan

2011-01-01T23:59:59.000Z

273

Electricity savings potentials in the residential sector of Bahrain  

SciTech Connect (OSTI)

Electricity is the major fuel (over 99%) used in the residential, commercial, and industrial sectors in Bahrain. In 1992, the total annual electricity consumption in Bahrain was 3.45 terawatt-hours (TWh), of which 1.95 TWh (56%) was used in the residential sector, 0.89 TWh (26%) in the commercial sector, and 0.59 TWh (17%) in the industrial sector. Agricultural energy consumption was 0.02 TWh (less than 1%) of the total energy use. In Bahrain, most residences are air conditioned with window units. The air-conditioning electricity use is at least 50% of total annual residential use. The contribution of residential AC to the peak power consumption is even more significant, approaching 80% of residential peak power demand. Air-conditioning electricity use in the commercial sector is also significant, about 45% of the annual use and over 60% of peak power demand. This paper presents a cost/benefit analysis of energy-efficient technologies in the residential sector. Technologies studied include: energy-efficient air conditioners, insulating houses, improved infiltration, increasing thermostat settings, efficient refrigerators and freezers, efficient water heaters, efficient clothes washers, and compact fluorescent lights. We conservatively estimate a 32% savings in residential electricity use at an average cost of about 4 fils per kWh. (The subsidized cost of residential electricity is about 12 fils per kWh. 1000 fils = 1 Bahrain Dinar = US$ 2.67). We also discuss major policy options needed for implementation of energy-efficiency technologies.

Akbari, H. [Lawrence Berkeley National Lab., CA (United States); Morsy, M.G.; Al-Baharna, N.S. [Univ. of Bahrain, Manama (Bahrain)

1996-08-01T23:59:59.000Z

274

RESIDENTIAL SERVICES STUDENT CHARTER Introduction  

E-Print Network [OSTI]

RESIDENTIAL SERVICES STUDENT CHARTER Introduction This Charter sets out the standards of provision. Residential Services are committed to encouraging diversity and inclusiveness within University residences via the Residential Services Annual Report and the internet. Consultation This Charter was developed

Oakley, Jeremy

275

CONSULTANT REPORT 2009 CALIFORNIA RESIDENTIAL  

E-Print Network [OSTI]

CONSULTANT REPORT 2009 CALIFORNIA RESIDENTIAL APPLIANCE SATURATION STUDY funded and administered a Residential Appliance Saturation Study that serves as an update to the 2003 electric and 10 natural gas residential enduses and appliance saturations for households

276

Energy Efficient, Environmentally Friendly Refrigerants  

E-Print Network [OSTI]

This paper describes a new family of safe, environmentally friendly, high performance substitute refrigerants for application in manufacturing and facilities operations. Due to the Montreal Protocol and subsequent environmental regulations, CFC...

Nimitz, J.; Glass, S.; Dhooge, P. M.

277

Essays on residential desegregation  

E-Print Network [OSTI]

Many ethnically diverse countries have policies that encourage integration across ethnic groups. This dissertation investigates the impact and welfare implications of a residential desegregation policy in Singapore, the ...

Wong, Maisy

2008-01-01T23:59:59.000Z

278

Residential Solar Rights  

Broader source: Energy.gov [DOE]

In 2007, New Jersey enacted legislation preventing homeowners associations from prohibiting the installation of solar collectors on certain types of residential properties. The term "solar...

279

Residential Rewards Program  

Broader source: Energy.gov [DOE]

The Focus on Energy Program offers a Residential Rewards Program to eligible residents for purchasing and installing furnaces, boilers, heat pumps, air sealing, attic insulation, and water heaters....

280

GEA Refrigeration Technologies / GEA Refrigeration Germany GmbH Wolfgang Dietrich / Dr. Ole Fredrich  

E-Print Network [OSTI]

GEA Refrigeration Technologies / GEA Refrigeration Germany GmbH Wolfgang Dietrich / Dr. Ole Technologies3 Achema 2012 // heat pumps using ammonia Industrial demand on heat in Germany Heatdemandin

Oak Ridge National Laboratory

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Analysis of heat recovery in supermarket refrigeration system using carbon dioxide as refrigerant.  

E-Print Network [OSTI]

?? The aim of this study is to investigate the heat recovery potential in supermarket refrigeration systems using CO2 as refrigerants. The theoretical control strategy… (more)

Abdi, Amir

2014-01-01T23:59:59.000Z

282

Performance of HCFC22 alternative refrigerants  

SciTech Connect (OSTI)

In this study, 14 refrigerant mixtures composed of R32, R125, R134a, R152a, R290(Propane) and R1270(Propylene) were tested in a breadboard heat pump in an attempt to replace R22 used in residential air-conditioners. The test heat pump was of 1 ton capacity with water as the secondary heat transfer fluids. All tests were conducted under ARI test A condition. Test results how that ternary mixtures composed of R32, R125, and R134a have 4 {approximately} 5% higher coefficient of performance(COP) and capacity than R22. Hence they seem to be promising alternatives for R22. On the other hand, ternary mixtures containing R125, R134a, and R152a have lower COPs and capacities than R22. R290/R134 azeotrope also shows 3--4% increases in COP and capacity. The compressor discharge and dome temperatures of all the mixtures tested are lower than those of R22 by 15.9--34.7 C and 5.5--14.3 C respectively, indicating that these mixtures would offer better system reliability and longer life time than R22. Finally, the test results with a suction line heat exchanger (SLHX) indicated that SLHX must be used with special care in air-conditioners since its effect is fluid dependent.

Jung, D.; Kim, C.B.; Song, Y.J.; Park, B.J.

1999-07-01T23:59:59.000Z

283

Citizens Gas- Residential Efficiency Rebates  

Broader source: Energy.gov [DOE]

Citizens Gas of Indiana offers rebates to its residential customers for the installation of several types of efficient natural gas appliances. Rebates are generally available for residential homes...

284

Efficiency Maine Residential Lighting Program  

Broader source: Energy.gov [DOE]

Efficiency Maine's Residential Lighting Program works directly with retailers and manufacturers to encourage residential customers to purchase energy-efficient lighting. Rebate amounts average $1...

285

Residential Retrofit Program Design Guide  

Broader source: Energy.gov [DOE]

This Residential Retrofit Program Design Guide focuses on the key elements and design characteristics of building and maintaining a successful residential retrofit program.

286

Non-intrusive refrigerant charge indicator  

DOE Patents [OSTI]

A non-intrusive refrigerant charge level indicator includes a structure for measuring at least one temperature at an outside surface of a two-phase refrigerant line section. The measured temperature can be used to determine the refrigerant charge status of an HVAC system, and can be converted to a pressure of the refrigerant in the line section and compared to a recommended pressure range to determine whether the system is under-charged, properly charged or over-charged. A non-intrusive method for assessing the refrigerant charge level in a system containing a refrigerant fluid includes the step of measuring a temperature at least one outside surface of a two-phase region of a refrigerant containing refrigerant line, wherein the temperature measured can be converted to a refrigerant pressure within the line section.

Mei, Viung C.; Chen, Fang C.; Kweller, Esher

2005-03-22T23:59:59.000Z

287

Magnetic Refrigeration Technology for High Efficiency Air Conditioning  

SciTech Connect (OSTI)

Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate heat exchangers or oil distribution issues found in traditional vapor compression systems.

Boeder, A; Zimm, C

2006-09-30T23:59:59.000Z

288

Bryant Residential Tutorship BRYANT RESIDENTIAL TUTORSHIP REGULATIONS FOR 2013  

E-Print Network [OSTI]

Bryant Residential Tutorship 1 BRYANT RESIDENTIAL TUTORSHIP REGULATIONS FOR 2013 BACKGROUND The D, Bryant Hall has provided a supportive residential environment for first-year students and has also in the Waikato region continues in the form of the Bryant Residential Tutorships. These Tutorships were offered

Waikato, University of

289

Energy-conservation program: notice of proposed rulemaking  

SciTech Connect (OSTI)

A notice of proposed rulemaking, proposing energy efficiency standards for refrigerators, refrigerator-freezers, freezers, clothes dryers, water heaters, room air conditioners, home heating equipment (not including furnaces) kitchen ranges and ovens, and central air conditioners ispresented. Comments are invited and the procedure for public comment is detailed. Issues included and presented in the proposed rulemaking are: determination of energy efficiency levels, macro-economic analysis, certification and enforcement, effect on other law, small business exemptions, environmental assessment, and regulatory analysis. (MCW)

Not Available

1980-06-12T23:59:59.000Z

290

Adjustable speed drive for residential applications  

SciTech Connect (OSTI)

This paper describes a demonstration of an adjustable speed drive suitable for use in residential applications such as compressors and fans in heat pumps, air conditioners, and refrigerators. The adjustable speed drive uses only a four-diode rectifier and a six-transistor six-diode inverter and does not require a source-frequency filter inductor or capacitor. Motor speed is adjusted with source-frequency phase control eliminating the switching loss and electromagnetic interference caused by the more commonly used high-frequency pulse-width modulation. Low source-current distortion and high power factor are obtained at a full-load operating point which is found using a parametric analysis.

Jungreis, A.M.; Kelley, A.W. [North Carolina State Univ., Raleigh, NC (United States). Dept. of Electrical and Computer Engineering] [North Carolina State Univ., Raleigh, NC (United States). Dept. of Electrical and Computer Engineering

1995-11-01T23:59:59.000Z

291

Loveland Water and Power- Refrigerator Recycling Program  

Broader source: Energy.gov [DOE]

Loveland Water and Power is providing an incentive for its customers to recycle their old refrigerators. Interested customers can call the utility to arrange a time to pick up the old refrigerator...

292

Cospolich Refrigerator: Order (2013-CE-5314)  

Broader source: Energy.gov [DOE]

DOE ordered Cospolich Refrigerator Co, Inc. to pay a $8,000 civil penalty after finding Cospolich Refrigerator had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

293

International Refrigeration: Order (2012-CE-1510)  

Broader source: Energy.gov [DOE]

DOE ordered International Refrigeration Products to pay an $8,000 civil penalty after finding International Refrigeration had failed to certify that certain room air conditioners comply with the applicable energy conservation standard.

294

Energy Saving with Absorption Refrigeration Technologies  

E-Print Network [OSTI]

Absorption refrigeration technology can be an economical and cost effective means of reducing energy cost and/or improving the efficiency and output of your process. We believe the potential benefits of absorption refrigeration technology have...

Davis, R. C.

1984-01-01T23:59:59.000Z

295

Refrigerator Manufacturers: Order (2013-CE-5341)  

Broader source: Energy.gov [DOE]

DOE ordered Refrigerator Manufacturers, LLC to pay a $8,000 civil penalty after finding Refrigerator Manufacturers had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

296

Landholders, Residential Land Conversion, and Market Signals  

E-Print Network [OSTI]

465– Margulis: Landholders, Residential Land Conversion, and1983. An Analysis of Residential Developer Location FactorsHow Regulation Affects New Residential Development. New

Margulis, Harry L.

2006-01-01T23:59:59.000Z

297

RESIDENTIAL THERMOSTATS: COMFORT CONTROLS IN CALIFORNIA HOMES  

E-Print Network [OSTI]

Report on Applicability of Residential Ventilation StandardsCharacterization of Residential New Construction PracticesJ - Load Calculation for Residential Winter and Summer Air

Meier, Alan K.

2008-01-01T23:59:59.000Z

298

Fact Sheet: Better Buildings Residential Network  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Fact Sheet BETTER BUILDINGS RESIDENTIAL NETWORK Learn more at betterbuildings.energy.govbbrn What Is the Residential Network? The Better Buildings Residential Network connects...

299

Fact Sheet: Better Buildings Residential Network | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Fact Sheet: Better Buildings Residential Network Fact Sheet: Better Buildings Residential Network Fact Sheet: Better Buildings Residential Network, increasing the number of...

300

Residential Retrofit Program Design Guide Overview Transcript...  

Broader source: Energy.gov (indexed) [DOE]

Residential Retrofit Program Design Guide Overview Transcript.doc Residential Retrofit Program Design Guide Overview Transcript.doc Residential Retrofit Program Design Guide...

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Method and apparatus for desuperheating refrigerant  

DOE Patents [OSTI]

The present invention is an apparatus and method for de-superheating a primary refrigerant leaving a compressor wherein a secondary refrigerant is used between the primary refrigerant to be de-superheated. Reject heat is advantageously used for heat reclaim.

Zess, James A. (Kelso, WA); Drost, M. Kevin (Richland, WA); Call, Charles J. (Richland, WA)

1997-01-01T23:59:59.000Z

302

Ternary Dy-Er-Al magnetic refrigerants  

DOE Patents [OSTI]

A ternary magnetic refrigerant material comprising (Dy{sub 1{minus}x}Er{sub x})Al{sub 2} for a magnetic refrigerator using the Joule-Brayton thermodynamic cycle spanning a temperature range from about 60K to about 10K, which can be adjusted by changing the Dy to Er ratio of the refrigerant. 29 figs.

Gschneidner, K.A. Jr.; Takeya, Hiroyuki

1995-07-25T23:59:59.000Z

303

Ternary Dy-Er-Al magnetic refrigerants  

DOE Patents [OSTI]

A ternary magnetic refrigerant material comprising (Dy.sub.1-x Er.sub.x)Al.sub.2 for a magnetic refrigerator using the Joule-Brayton thermodynamic cycle spanning a temperature range from about 60K to about 10K, which can be adjusted by changing the Dy to Er ratio of the refrigerant.

Gschneidner, Jr., Karl A. (Ames, IA); Takeya, Hiroyuki (Ibaraki, JP)

1995-07-25T23:59:59.000Z

304

Wheel-type magnetic refrigerator  

DOE Patents [OSTI]

The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load. 7 figs.

Barclay, J.A.

1983-10-11T23:59:59.000Z

305

Recommendations for energy conservation standards for new residential buildings: Volume 2: Automated residential energy standard---user's guide--version 1. 1  

SciTech Connect (OSTI)

This report documents the development and testing of a set of recommendations from the American Society of Heating, Refrigeration and Air Conditioning Engineers, Inc. (ASHRAE) Special Projects Committee No. 53, designed to provide the technical foundation for the Congressionally-mandated energy standard for new residential buildings. The recommendations were developed over a 25-month period by a multidisciplinary project team under the management of the DOE and its prime contractor, Pacific Northwest Laboratory (PNL).

Lortz, V.B.; Taylor, Z.T.

1989-05-01T23:59:59.000Z

306

EA-2001: Energy Efficiency Design Standards: New Federal Commercial and Multi-Family High-Rise Residential Buildings and New Federal Low-Rise Residential Buildings  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy (DOE) is publishing this final rule to implement provisions in the Energy Conservation and Production Act (ECPA) that require DOE to update the baseline Federal energy efficiency performance standards for the construction of new Federal commercial and multi-family high-rise residential buildings. This rule updates the baseline Federal commercial standard to the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 90.1-2013.

307

Residential Wind Power  

E-Print Network [OSTI]

This research study will explore the use of residential wind power and associated engineering and environmental issues. There is various wind power generating devices available to the consumer. The study will discuss the dependencies of human...

Willis, Gary

2011-12-16T23:59:59.000Z

308

Residential Energy Disclosure (Hawaii)  

Broader source: Energy.gov [DOE]

A residential property owner is required to disclose electricity costs for the most recent three-month period in which the property was occupied as a condition of selling it. No proof or copies of...

309

Residential Solar Tax Credit  

Broader source: Energy.gov [DOE]

Enacted in August 1997, this personal income tax credit originally applied to expenditures on solar-electric (PV) equipment used on residential property. The credit, equal to 25% percent of the...

310

Optimization of Industrial Refrigeration Systems  

E-Print Network [OSTI]

A computer program designed to optimize the size of an evaporative condenser in a two-stage industrial refrigeration plant was created. The program sizes both the high-stage and low-stage compressors and an evaporative condenser. Once the initial...

Flack, P. J.; Sharp, M. K.; Case, M. E.; Gregory, R. W.; Case, P. L.

311

Direct condensation refrigerant recovery and restoration system  

SciTech Connect (OSTI)

This patent describes a refrigerant recovery and purification system for removing gaseous refrigerant from a disabled refrigeration unit, cleaning the refrigerant of contaminants, and converting the gaseous refrigerant to a liquid state for storage. It comprises a low pressure inlet section; a high pressure storage section; the low pressure inlet section comprising: an oil and refrigerant gas separator, including a separated oil removal means, first conduit means for connecting an inlet of the separator to the disabled refrigerant unit, a slack-sided accumulator, second conduit means connecting the separator to the slack-sided accumulator, a reclaim condenser, third conduit means connecting the separator and the reclaim condenser in series, an evaporator coil in the reclaim condenser connectable to a conventional operating refrigeration system for receiving a liquid refrigerant under pressure for expansion therein, the evaporator coil forming a condensing surface for condensing the refrigerant gas at near atmospheric pressure in the condenser, a liquid receiver, a reclaimed refrigerant storage tank, fourth conduit means further connecting the liquid receiver in series with the reclaim condenser, downstream thereof, means between the reclaim condenser and the liquid receiver.

Grant, D.C.H.

1992-03-10T23:59:59.000Z

312

National Residential Efficiency Measures Database Webinar Slides...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

National Residential Efficiency Measures Database Webinar Slides National Residential Efficiency Measures Database Webinar Slides Presentation slides for the Building Technologies...

313

Building America Webinar: National Residential Efficiency Measures...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

National Residential Efficiency Measures Database Unveiled Building America Webinar: National Residential Efficiency Measures Database Unveiled This webinar presented an overview...

314

Better Buildings Residential Program Solution Center Demonstration...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Program Solution Center Demonstration Webinar Transcript Better Buildings Residential Program Solution Center Demonstration Webinar Transcript The Better Buildings Residential...

315

Conference Agenda: Residential Energy Efficiency Solutions 2012...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Conference Agenda: Residential Energy Efficiency Solutions 2012 Conference Agenda: Residential Energy Efficiency Solutions 2012 Presents conference agenda including a general...

316

Behavioral Assumptions Underlying California Residential Sector...  

Broader source: Energy.gov (indexed) [DOE]

Behavioral Assumptions Underlying California Residential Sector Energy Efficiency Programs (2009 CIEE Report) Behavioral Assumptions Underlying California Residential Sector Energy...

317

Better Buildings Residential Program Solution Center Demonstration...  

Energy Savers [EERE]

Better Buildings Residential Program Solution Center Demonstration Webinar Better Buildings Residential Program Solution Center Demonstration Webinar Demonstration webinar slides...

318

Application of Best Industry Practices to the Design of Commercial Refrigerators  

SciTech Connect (OSTI)

The substantial efficiency improvements which have been realized in residential refrigerators over the last twenty years due to implementation of the National Appliance Energy Conservation Act and changing consumer reactions to energy savings give an indication of the potential for improvement in the commercial sector, where few such efficiency improvements have been made to date. The purchase decision for commercial refrigerators is still focused primarily on first cost and product performance issues such as maximizing storage capacity, quick pulldown, durability, and reliability. The project applied techniques used extensively to reduce energy use in residential refrigeration to a commercial reach-in refrigerator. The results will also be applicable to other commercial refrigeration equipment, such as refrigerated vending machines, reach-in freezers, beverage merchandisers, etc. The project described in this paper was a collaboration involving the Appliance and Building Technology Sector of TIAX, the Delfield Company, and the U. S. Department of Energy's Office of Building Technologies. Funding was provided by DOE through Cooperative Agreement No. DE-FC26-00NT41000. The program plan and schedule were structured to assure successful integration of the TIAX work on development of efficient design concepts into Delfield's simultaneous development of the Vantage product line. The energy-saving design options evaluated as part of the development included brushless DC and PSC fan motors, high-efficiency compressors, variable-speed compressor technology, cabinet thermal improvement (particularly in the face frame area), increased insulation thickness, a trap for the condensate line, improved insulation, reduced-wattage antisweat heaters, non-electric antisweat heating, off-cycle defrost termination, rifled heat exchanger tubing, and system optimization (selection of heat exchangers, fans, and subcooling, superheat, and suction temperatures for efficient operation). The project started with a thorough evaluation of the baseline Delfield Model 6051 two-door reach-in refrigerator. Performance testing was done to establish a performance baseline which, to meet end-users requirements, would have to be met or exceeded by the high-efficiency refrigerator design. Energy testing was done to establish the baseline energy use. Diagnostic testing such as reverse heat leak testing and insulation conductivity testing was done to evaluate factors contributing to the cabinet load and energy use. Modeling was done to assess the energy savings potential of the energy saving design options. Discussion with vendors and cost modeling was done to assess the manufacturing cost impact of the options. Based on this work, the following group of design options was selected for incorporation in the final refrigerator design: (1) Brushless DC evaporator fans; (2) Improved face frame design; (3) Reduced antisweat heater wattage; (4) Condensate line trap; and (5) Optimized refrigeration system. There was no net cost premium associated with these design changes, leading to a high-efficiency design requiring no payback of any initial additional investment. Delfield incorporated these design options in the Vantage line design and built a first prototype, which was tested at TIAX. Additional design changes were implemented in the transition to manufacturing, based in part on results of initial prototype testing, and a pilot production unit was sent to TIAX for final testing. The energy use of the pilot production unit was 68% less than that of the baseline refrigerator when tested according to the ASHRAE 117 Energy Test Standard. The energy test results for the baseline refrigerator and the two new-design units is shown in Figure ES-1 below. The resulting energy consumption is well below Energy Star and proposed Canadian and California standards levels. Delfield has successfully transitioned the design to production and is manufacturing all configurations of the energy efficient reach-ins at a rate greater than 7,000 per year, with production quantities projec

None

2002-06-30T23:59:59.000Z

319

RESIDENTIAL PROGRAM FOR LANGUAGE LEARNING  

E-Print Network [OSTI]

RESIDENTIAL PROGRAM FOR LANGUAGE LEARNING Live on-campus in 2014-15 and participate in a unique as part of a residential community in Arroyo Vista! Open to all undergraduate students with 2-3 years

Loudon, Catherine

320

HFC supermarket refrigeration demonstration. Phases 1 and 2  

SciTech Connect (OSTI)

The HFC Supermarket Refrigeration Demonstration tested and evaluated HFC refrigerants in a new Shop `n Save supermarket in Glens Falls, New York. This project included laboratory testing of HFC refrigerants for medium- and low-temperature application, the design of a supermarket refrigeration system to accommodate the new refrigerants, installation, start-up, and field monitoring.

Borhanian, H.; Rafuse, L.

1996-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Sample Residential Program Term Sheet  

Broader source: Energy.gov (indexed) [DOE]

Goal DRAFT U.S. DOE Sample Residential Program Term Sheet - DRAFT Introduction is seeking to develop an energy...

322

Questions Asked during the Financing Residential Energy Efficiency...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Residential Energy Efficiency with Carbon Offsets Transcript Financing Residential Energy Efficiency with Carbon Offsets SERC Photovoltaics for Residential Buildings Webinar...

323

Suction muffler for refrigeration compressor  

DOE Patents [OSTI]

A hermetic refrigeration compressor includes a suction muffler formed from two pieces of plastic material mounted on the cylinder housing. One piece is cylindrical in shape with an end wall having an aperture for receiving a suction tube connected to the cylinder head. The other piece fits over and covers the other end of the cylindrical piece, and includes a flaring entrance horn which extends toward the return line on the sidewall of the compressor shell. 5 figs.

Nelson, R.T.; Middleton, M.G.

1983-01-25T23:59:59.000Z

324

Residential & Business Services Director's Office  

E-Print Network [OSTI]

Residential & Business Services Director's Office Butts Wynd, North Street, St Andrews, Fife, KY16 by students for students are an integral part of student life and intrinsic to the student residential the residential environment. However, experience tells us that events require careful planning and organisation

Brierley, Andrew

325

STATE OF CALIFORNIA RESIDENTIAL LIGHTING  

E-Print Network [OSTI]

STATE OF CALIFORNIA RESIDENTIAL LIGHTING CEC-CF-6R-LTG-01 (Revised 08/09) CALIFORNIA ENERGY COMMISSION INSTALLATION CERTIFICATE CF-6R-LTG-01 Residential Lighting (Page 1 of 6) Site Address: Enforcement Agency: Permit Number: 2008 Residential Compliance Forms August 2009 1. Kitchen Lighting Does project

326

Permanent Home Number: Residential Number  

E-Print Network [OSTI]

Permanent Home Number: Residential Number: Mobile: Please update my contact details. Signature nominated correspondence address as indicated below. Permanent Home Adress Residential Address Other Address (Must not be a PO Box) Residential Address (Must not be a PO Box) Other - Postal/Optional Address

Viglas, Anastasios

327

Solid-Vapor Sorption Refrigeration Systems  

E-Print Network [OSTI]

adsorbents in heat pump cycles: 1. A high usable refrigerant mass per unit mass of adsorbent. 2. A high energy of adsorption and desorption. 3. Heat flows and composition changes occur at constant temperature. The advantages of complex compounds... 2. Useable refrigerant densities. Summarizing, complex compound exhibit inherent characteristics which make them ideal adsorbents in heat pump cycles: 1. A high usable refrigerant mass per unit mass of adsorbent. 2. A high energy of adsorption...

Graebel, W.; Rockenfeller, U.; Kirol, L.

328

Practical Diagnostics for Evaluating Residential Commissioning Metrics  

SciTech Connect (OSTI)

In this report, we identify and describe 24 practical diagnostics that are ready now to evaluate residential commissioning metrics, and that we expect to include in the commissioning guide. Our discussion in the main body of this report is limited to existing diagnostics in areas of particular concern with significant interactions: envelope and HVAC systems. These areas include insulation quality, windows, airtightness, envelope moisture, fan and duct system airflows, duct leakage, cooling equipment charge, and combustion appliance backdrafting with spillage. Appendix C describes the 83 other diagnostics that we have examined in the course of this project, but that are not ready or are inappropriate for residential commissioning. Combined with Appendix B, Table 1 in the main body of the report summarizes the advantages and disadvantages of all 107 diagnostics. We first describe what residential commissioning is, its characteristic elements, and how one might structure its process. Our intent in this discussion is to formulate and clarify these issues, but is largely preliminary because such a practice does not yet exist. Subsequent sections of the report describe metrics one can use in residential commissioning, along with the consolidated set of 24 practical diagnostics that the building industry can use now to evaluate them. Where possible, we also discuss the accuracy and usability of diagnostics, based on recent laboratory work and field studies by LBNL staff and others in more than 100 houses. These studies concentrate on evaluating diagnostics in the following four areas: the DeltaQ duct leakage test, air-handler airflow tests, supply and return grille airflow tests, and refrigerant charge tests. Appendix A describes those efforts in detail. In addition, where possible, we identify the costs to purchase diagnostic equipment and the amount of time required to conduct the diagnostics. Table 1 summarizes these data. Individual equipment costs for the 24 practical diagnostics range from a few hundred dollars to many thousands of dollars. The higher costs are associated with infrared thermography and state-of-the-art automated diagnostic systems. Most tests can be performed in one hour or less, using equipment priced toward the lower end of the cost spectrum.

Wray, Craig; Walker, Iain; Siegel, Jeff; Sherman, Max

2002-06-11T23:59:59.000Z

329

IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems Corresponding author: P. Leblay  

E-Print Network [OSTI]

3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems Corresponding author: P on the refrigerant side and louver fins on the air side. The flat tubes are grouped within a header, to use the heat exchangers with round tubes, such as charge reduction and higher heat transfer efficiency. But a reduced

Paris-Sud XI, Université de

330

Covered Product Category: Commercial Refrigerators and Freezers  

Broader source: Energy.gov [DOE]

The Federal Energy Management Program (FEMP) provides acquisition guidance for commercial refrigerators and freezers, which are covered by the ENERGY STAR program.

331

Natural Refrigerant (R-729) Heat Pump  

Energy Savers [EERE]

Manufactured in the U.S. 2 Problem Statement * Current commercial and industrial heat pumps - Poor coefficient of performance (COP) at low temperatures * HFC refrigerant...

332

Covered Product Category: Refrigerated Beverage Vending Machines...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

vending machines are equipped with controls or software that put the lighting andor refrigeration systems into a low power state at night, on weekends, or other periods of...

333

Layer of protection analysis applied to ammonia refrigeration systems  

E-Print Network [OSTI]

Ammonia refrigeration systems are widely used in industry. Demand of these systems is expected to increase due to the advantages of ammonia as refrigerant and because ammonia is considered a green refrigerant. Therefore, it is important to evaluate...

Zuniga, Gerald Alexander

2009-05-15T23:59:59.000Z

334

High SEER Residential AC  

SciTech Connect (OSTI)

This article discusses the new offerings of residential air conditioning systems with very high Seasonal Energy Efficiency Ratio (SEER) ratings, the two regional areas dictating operations standards ("hot, humid" and "hot, dry"), and the potential energy savings these new systems can provide. The article concludes with a brief review of current market potential.

Hastbacka, Mildred; Dieckmann, John; Brodrick, James

2012-07-31T23:59:59.000Z

335

STORM WATER Residential  

E-Print Network [OSTI]

STORM WATER QUALITY HOTLINE UCSC Residential Car Washing http THAT MAY CAUSE ENVIRONMENTAL HARM TO THE STORM WATER QUALITY HOTLINE: (831) 459-2553. LIKE US ON FACEBOOK AT UCSC STORM WATER MANAGEMENT PROGRAM! DID YOU KNOW? PRACTICAL SOLUTIONS > USE A COMMERCIAL CAR WASH

California at Santa Cruz, University of

336

Residential Mechanical Precooling  

SciTech Connect (OSTI)

This research conducted by the Alliance for Residential Building Innovation team evaluated mechanical air conditioner pre-cooling strategies in homes throughout the United States. EnergyPlus modeling evaluated two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes.

German, A.; Hoeschele, M.

2014-12-01T23:59:59.000Z

337

Residential Furnace Blower Performance  

E-Print Network [OSTI]

conditioner performance1 , standby power, as well as igniter and combustion air blower power. Energy savings for a typical three-and-a-half ton air conditioner with typical California ducts are 45 kWh. Peak demand combinations of blowers and residential furnaces were tested for air moving performance. The laboratory test

338

Energy Data Sourcebook for the U.S. Residential Sector  

E-Print Network [OSTI]

auto-defrost refrigerators and freezers, and solid-state/For example, new refrigerators and freezers have increasedfactors for refrigerators and freezers are based on data for

Wenzel, T.P.

2010-01-01T23:59:59.000Z

339

GridLAB-D Technical Support Document: Residential End-Use Module Version 1.0  

SciTech Connect (OSTI)

1.0 Introduction The residential module implements the following end uses and characteristics to simulate the power demand in a single family home: • Water heater • Lights • Dishwasher • Range • Microwave • Refrigerator • Internal gains (plug loads) • House (heating/cooling loads) The house model considers the following four major heat gains/losses that contribute to the building heating/cooling load: 1. Conduction through exterior walls, roof and fenestration (based on envelope UA) 2. Air infiltration (based on specified air change rate) 3. Solar radiation (based on CLTD model and using tmy data) 4. Internal gains from lighting, people, equipment and other end use objects. The Equivalent Thermal Parameter (ETP) approach is used to model the residential loads and energy consumption. The following sections describe the modeling assumptions for each of the above end uses and the details of power demand calculations in the residential module.

Taylor, Zachary T.; Gowri, Krishnan; Katipamula, Srinivas

2008-07-31T23:59:59.000Z

340

Active Diesel Emission Control Technology for Transport Refrigeration...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Transport Refrigeration Units Active Diesel Emission Control Technology for Transport Refrigeration Units This project discusses a CARB Level 2+ verified active regeneration...

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active Diesel Particulate Filters Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active Diesel Particulate...

342

DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy...  

Broader source: Energy.gov (indexed) [DOE]

Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements March 16, 2010 - 4:28pm...

343

2014-11-26 Issuance: Test Procedures for Miscellaneous Refrigeration...  

Energy Savers [EERE]

11-26 Issuance: Test Procedures for Miscellaneous Refrigeration Products; Notice of Proposed Rulemaking 2014-11-26 Issuance: Test Procedures for Miscellaneous Refrigeration...

344

2014-04-10 Issuance: Test Procedures for Commercial Refrigeration...  

Broader source: Energy.gov (indexed) [DOE]

0 Issuance: Test Procedures for Commercial Refrigeration Equipment; Final Rule 2014-04-10 Issuance: Test Procedures for Commercial Refrigeration Equipment; Final Rule This document...

345

Working Fluids Low Global Warming Potential Refrigerants - 2013...  

Energy Savers [EERE]

Working Fluids Low Global Warming Potential Refrigerants - 2013 Peer Review Working Fluids Low Global Warming Potential Refrigerants - 2013 Peer Review Emerging Technologies...

346

Chapter 7, Refrigerator Recycling Evaluation Protocol: The Uniform...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

environmentally harmful refrigerants and foam and enables the recycling of the plastic, metal, and wiring components. 1 Secondary refrigerators are units not located in the...

347

Air-Conditioning, Heating, and Refrigeration Institute (AHRI...  

Energy Savers [EERE]

Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI These...

348

Corrosion aspects in indirect systems with secondary refrigerants.  

E-Print Network [OSTI]

?? Aqueous solutions of organic or inorganic salts are used as secondary refrigerants in indirect refrigeration systems to transport and transfer heat. Water is known… (more)

Ignatowicz, Monika

2008-01-01T23:59:59.000Z

349

Thermodynamic Evaluation of Low-Global Warming Potential Refrigerants...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Evaluation of Low-Global-Warming-Potential Refrigerants Research & Development Roadmap: Next-Generation Low Global Warming Potential Refrigerants Next Generation Low-Global...

350

Working Fluids Low Global Warming Potential Refrigerants | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Center. Life Cycle Climate Performance of supermarket refrigeration.
Credit: Oak Ridge National Lab Life Cycle Climate Performance of supermarket refrigeration....

351

Thermodynamic Evaluation of Low-Global-Warming-Potential Refrigerants...  

Broader source: Energy.gov (indexed) [DOE]

Thermodynamic Evaluation of Low-Global-Warming-Potential Refrigerants Thermodynamic Evaluation of Low-Global-Warming-Potential Refrigerants Lead Performer: National Institute of...

352

Certification reporting forms  

SciTech Connect (OSTI)

The required information and formats for the certification report including the cover sheet, compliance statement, and body of the report are given in this document. The body of the reports is different for each product. There are no product-to-product differences in the forms of the other parts of the reports. The products covered in this document include: furnaces, water heaters, refrigerator-freezers, central air conditioners, room air conditioners, and freezers.

Not Available

1981-02-18T23:59:59.000Z

353

Seven-effect absorption refrigeration  

DOE Patents [OSTI]

A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit. 1 fig.

DeVault, R.C.; Biermann, W.J.

1989-05-09T23:59:59.000Z

354

Seven-effect absorption refrigeration  

DOE Patents [OSTI]

A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit.

DeVault, Robert C. (Knoxville, TN); Biermann, Wendell J. (Fayetteville, NY)

1989-01-01T23:59:59.000Z

355

Natural Refrigerant, Geothermal Heating & Cooling Solutions  

E-Print Network [OSTI]

, January 2013, www.danfoss.com/co2 DIRECT Refrigerant Leakage (GWP) INDIRECT Energy Consumption (COP Geothermal's Direct Exchange System Advantage: · All Natural, Safe & Non-toxic Refrigerant · Highly Efficient Equivalent Warming Impact Commercial Food and Retail Application: Direct Leakage > Energy Consumption Brown

356

Modeling supermarket refrigeration energy use and demand  

SciTech Connect (OSTI)

A computer model has been developed that can predict the performance of supermarket refrigeration equipment to within 3% of field test measurements. The Supermarket Refrigeration Energy Use and Demand Model has been used to simulate currently available refrigerants R-12, R-502 and R-22, and is being further developed to address alternative refrigerants. This paper reports that the model is expected to be important in the design, selection and operation of cost-effective, high-efficiency refrigeration systems. It can profile the operation and performance of different types of compressors, condensors, refrigerants and display cases. It can also simulate the effects of store humidity and temperature on display cases; the efficiency of various floating head pressure setpoints, defrost alternatives and subcooling methods; the efficiency and amount of heat reclaim from refrigeration systems; and the influence of other variables such as store lighting and building design. It can also be used to evaluate operational strategies such as variable-speed drive or cylinder unloading for capacity control. Development of the model began in 1986 as part of a major effort, sponsored by the U.S. electric utility industry, to evaluate energy performance of then conventional single compressor and state-of-the-art multiplex refrigeration systems, and to characterize the contribution of a variety of technology enhancement features on system energy use and demand.

Blatt, M.H.; Khattar, M.K. (Electric Power Research Inst., Palo Alto, CA (US)); Walker, D.H. (Foster Miller Inc., Waltham, MA (US))

1991-07-01T23:59:59.000Z

357

Duracold Refrigeration Manufacturing: Order (2013-CE-5342)  

Broader source: Energy.gov [DOE]

DOE ordered Duracold Refrigeration Manufacturing Company, LLC to pay a $8,000 civil penalty after finding Duracold Refrigeration Manufacturing had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

358

Commercial Refrigerator Door: Order (2013-CE-5351)  

Broader source: Energy.gov [DOE]

DOE ordered Commercial Refrigerator Door Company, Inc. to pay a $8,000 civil penalty after finding Commercial Refrigerator Door had failed to certify that a variety of models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

359

North Star Refrigerator: Order (2013-CE-5355)  

Broader source: Energy.gov [DOE]

DOE ordered North Star Refrigerator Co., Inc. to pay a $8,000 civil penalty after finding North Star Refrigerator had failed to certify that any basic models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

360

Dynamic simulation of a reverse Brayton refrigerator  

SciTech Connect (OSTI)

A test refrigerator based on the modified Reverse Brayton cycle has been developed in the Chinese Academy of Sciences recently. To study the behaviors of this test refrigerator, a dynamic simulation has been carried out. The numerical model comprises the typical components of the test refrigerator: compressor, valves, heat exchangers, expander and heater. This simulator is based on the oriented-object approach and each component is represented by a set of differential and algebraic equations. The control system of the test refrigerator is also simulated, which can be used to optimize the control strategies. This paper describes all the models and shows the simulation results. Comparisons between simulation results and experimental data are also presented. Experimental validation on the test refrigerator gives satisfactory results.

Peng, N.; Xiong, L. Y.; Dong, B.; Liu, L. Q. [State Key Laboratory of Technologies in Space Cryogenic Propellants, Technical Institute of Physics and Chemistry, CAS, Beijing, 100190 (China); Lei, L. L.; Tang, J. C. [State Key Laboratory of Technologies in Space Cryogenic Propellants, Technical Institute of Physics and Chemistry, CAS, Beijing, 100190 China and Graduate University of Chinese Academy of Sciences, Beijing, 100190 (China)

2014-01-29T23:59:59.000Z

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Oil cooled, hermetic refrigerant compressor  

DOE Patents [OSTI]

A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler 18 and is then delivered through the shell to the top of the motor rotor 24 where most of it is flung radially outwardly within the confined space provided by the cap 50 which channels the flow of most of the oil around the top of the stator 26 and then out to a multiplicity of holes 52 to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber 58 to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole 62 also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator 68 from which the suction gas passes by a confined path in pipe 66 to the suction plenum 64 and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum 64.

English, William A. (Murrysville, PA); Young, Robert R. (Murrysville, PA)

1985-01-01T23:59:59.000Z

362

Oil cooled, hermetic refrigerant compressor  

DOE Patents [OSTI]

A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler and is then delivered through the shell to the top of the motor rotor where most of it is flung radially outwardly within the confined space provided by the cap which channels the flow of most of the oil around the top of the stator and then out to a multiplicity of holes to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator from which the suction gas passes by a confined path in pipe to the suction plenum and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum. 3 figs.

English, W.A.; Young, R.R.

1985-05-14T23:59:59.000Z

363

PowerChoice Residential Customer Response to TOU Rates  

E-Print Network [OSTI]

Savings from Residential Energy Demand Feedback Devices. ”residential energy consumption, load shifting, consumption feedback

Peters, Jane S.

2010-01-01T23:59:59.000Z

364

Residential Absorption Water Heater  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l LPROJECTS IN RENEWABLE ENERGY FOR HIGH SCHOOL| DepartmentResidential

365

Residential Buildings Integration (RBI)  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l LPROJECTS IN RENEWABLE ENERGY FOR HIGH SCHOOL| DepartmentResidential|

366

Detailed residential electric determination  

SciTech Connect (OSTI)

Data on residential loads has been collected from four residences in real time. The data, measured at 5-second intervals for 53 days of continuous operation, were statistically characterized. An algorithm was developed and incorporated into the modeling code SOLCEL. Performance simulations with SOLCEL using these data as well as previous data collected over longer time intervals indicate that no significant errors in system value are introduced through the use of long-term average data.

Not Available

1984-06-01T23:59:59.000Z

367

Lehigh University Office of Residential Services  

E-Print Network [OSTI]

Lehigh University Office of Residential Services Resident Check-Out Form Students are expected and furniture of all personal property. Residential Services is not responsible for any personal items left and residential administration staff for billing purposes. Signature

Napier, Terrence

368

Vanderbilt University Office of Housing & Residential Education  

E-Print Network [OSTI]

Vanderbilt University Office of Housing & Residential Education RESIDENTADVISERRECRUITMENT2015 Adviser (RA) is a paraprofessional student staff member for the Office of Housing and Residential Coordinators, Head Residents, and faculty to create a premiere residential experience where students can learn

Bordenstein, Seth

369

2009 CALIFORNIA RESIDENTIAL APPLIANCE SATURATION STUDY  

E-Print Network [OSTI]

2009 CALIFORNIA RESIDENTIAL APPLIANCE SATURATION STUDY Volume 1 and administered a Residential Appliance Saturation Study that serves as an update to the 2003 RASS, with the same residential enduses and appliance saturations for households. These consumption estimates were developed

370

2009 CALIFORNIA RESIDENTIAL APPLIANCE SATURATION STUDY  

E-Print Network [OSTI]

2009 CALIFORNIA RESIDENTIAL APPLIANCE SATURATION STUDY Executive and administered a Residential Appliance Saturation Study that serves as an update to the 2003 RASS, with the same residential enduses and appliance saturations for households. These consumption estimates were developed

371

Your Resource Guide to WVU's Residential  

E-Print Network [OSTI]

Your Resource Guide to WVU's Residential Learning Communities Eyes&'Eers 2014­ 2015 Academic throughout the summer. welcomeweek.wvu.edu Residential Education Programming Opportunities Volleypalooza Scarehouse Rich's Fright Farm (Haunted House) Kennywood Fright Night Residential Education Octoberfest

Mohaghegh, Shahab

372

http://warren.ucsd.edu 1 Residential  

E-Print Network [OSTI]

http://warren.ucsd.edu 1 Warren Resources Residential Life Student Conduct University Resources Off and Employment 10 Section II: Residential Life Introduction 11 Residential Life Policies 13 Section III: Student

Tsien, Roger Y.

373

RESIDENTIAL BURGLARY DATE: November 25, 2014  

E-Print Network [OSTI]

RESIDENTIAL BURGLARY DATE: November 25, 2014 INCIDENT / LOCATION: Residential Burglary in Vista Del 22, 2014, at approximately 11:07 pm, the UCI Police Department received a report of a residential

Rose, Michael R.

374

Unitil- Residential Energy Efficiency Programs  

Broader source: Energy.gov [DOE]

Unitil offers New Hampshire residential customers a number of programs to encourage more energy efficient homes. The Energy Star Appliance Program provides rebates for clothes washers, air...

375

NYSEG (Gas)- Residential Efficiency Program  

Broader source: Energy.gov [DOE]

NYSEG is offering residential natural gas customers rebates for installing energy efficient equipment. Customers can complete one rebate application for multiple pieces of equipment as long as...

376

SMUD- Residential Solar Loan Program  

Broader source: Energy.gov [DOE]

The Sacramento Municipal Utility District's (SMUD) Residential Loan Program provides 100% financing to customers who install solar water heating systems. All solar water heating systems must meet...

377

Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)  

SciTech Connect (OSTI)

Electrical energy consumption of the residential sector is a crucial area of research that has in the past primarily focused on increasing the efficiency of household devices such as water heaters, dishwashers, air conditioners, and clothes washer and dryer units. However, the focus of this research is shifting as objectives such as developing the smart grid and ensuring that the power system remains reliable come to the fore, along with the increasing need to reduce energy use and costs. Load research has started to focus on mechanisms to support the power system through demand reduction and/or reliability services. The power system relies on matching generation and load, and day-ahead and real-time energy markets capture most of this need. However, a separate set of grid services exist to address the discrepancies in load and generation arising from contingencies and operational mismatches, and to ensure that the transmission system is available for delivery of power from generation to load. Currently, these grid services are mostly provided by generation resources. The addition of renewable resources with their inherent variability can complicate the issue of power system reliability and lead to the increased need for grid services. Using load as a resource, through demand response programs, can fill the additional need for flexible resources and even reduce costly energy peaks. Loads have been shown to have response that is equal to or better than generation in some cases. Furthermore, price-incentivized demand response programs have been shown to reduce the peak energy requirements, thereby affecting the wholesale market efficiency and overall energy prices. The residential sector is not only the largest consumer of electrical energy in the United States, but also has the highest potential to provide demand reduction and power system support, as technological advancements in load control, sensor technologies, and communication are made. The prevailing loads based on the largest electrical energy consumers in the residential sector are space heating and cooling, washer and dryer, water heating, lighting, computers and electronics, dishwasher and range, and refrigeration. As the largest loads, these loads provide the highest potential for delivering demand response and reliability services. Many residential loads have inherent flexibility that is related to the purpose of the load. Depending on the load type, electric power consumption levels can either be ramped, changed in a step-change fashion, or completely removed. Loads with only on-off capability (such as clothes washers and dryers) provide less flexibility than resources that can be ramped or step-changed. Add-on devices may be able to provide extra demand response capabilities. Still, operating residential loads effectively requires awareness of the delicate balance of occupants health and comfort and electrical energy consumption. This report is Phase I of a series of reports aimed at identifying gaps in automated home energy management systems for incorporation of building appliances, vehicles, and renewable adoption into a smart grid, specifically with the intent of examining demand response and load factor control for power system support. The objective is to capture existing gaps in load control, energy management systems, and sensor technology with consideration of PHEV and renewable technologies to establish areas of research for the Department of Energy. In this report, (1) data is collected and examined from state of the art homes to characterize the primary residential loads as well as PHEVs and photovoltaic for potential adoption into energy management control strategies; and (2) demand response rules and requirements across the various demand response programs are examined for potential participation of residential loads. This report will be followed by a Phase II report aimed at identifying the current state of technology of energy management systems, sensors, and communication technologies for demand response and load factor control applications

Starke, Michael R [ORNL; Onar, Omer C [ORNL; DeVault, Robert C [ORNL

2011-09-01T23:59:59.000Z

378

Dual-circuit, multiple-effect refrigeration system and method  

DOE Patents [OSTI]

A dual circuit absorption refrigeration system comprising a high temperature single-effect refrigeration loop and a lower temperature double-effect refrigeration loop separate from one another and provided with a double-condenser coupling therebetween. The high temperature condenser of the single-effect refrigeration loop is double coupled to both of the generators in the double-effect refrigeration loop to improve internal heat recovery and a heat and mass transfer additive such as 2-ethyl-1-hexanol is used in the lower temperature double-effect refrigeration loop to improve the performance of the absorber in the double-effect refrigeration loop.

DeVault, Robert C. (Knoxville, TN)

1995-01-01T23:59:59.000Z

379

Evaluation of evolving residential electricity tariffs  

E-Print Network [OSTI]

residential electricity tariffs Judy Lai, Nicholas DeForest,residential electricity tariffs Judy Lai – Senior Researchfrom the current 5-tiered tariff to time variable pricing,

Lai, Judy

2011-01-01T23:59:59.000Z

380

Tacoma Power- Residential Weatherization Rebate Program  

Broader source: Energy.gov [DOE]

Tacoma Power helps residential customers increase the energy efficiency of homes through the utility's residential weatherization program. Weatherization upgrades to windows are eligible for an...

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Building America Residential Energy Efficiency Research Planning...  

Broader source: Energy.gov (indexed) [DOE]

Research Planning meeting in October 2011, held in Washington, D.C. Residential Energy Efficiency Planning Meeting Summary Report More Documents & Publications Residential Energy...

382

Residential Energy Efficiency Customer Service Best Practices...  

Energy Savers [EERE]

Residential Energy Efficiency Customer Service Best Practices Peer Exchange Call Residential Energy Efficiency Customer Service Best Practices Peer Exchange Call January 22, 2015...

383

Building America Residential Energy Efficiency Technical Update...  

Energy Savers [EERE]

Residential Energy Efficiency Technical Update Meeting: August 2011 Building America Residential Energy Efficiency Technical Update Meeting: August 2011 On this page, you may link...

384

Residential Tax Credits Boost Maryland Geothermal Business |...  

Broader source: Energy.gov (indexed) [DOE]

Residential Tax Credits Boost Maryland Geothermal Business Residential Tax Credits Boost Maryland Geothermal Business June 18, 2010 - 12:09pm Addthis Paul Lester Communications...

385

Better Buildings Residential Network Case Study: Partnerships...  

Energy Savers [EERE]

Case Study: Partnerships Better Buildings Residential Network Case Study: Partnerships Better Buildings Residential Network Case Study: Partnerships, from the U.S. Department of...

386

RESIDENTIAL WEATHERIZATION SPECIFICATIONS August 30, 2011  

E-Print Network [OSTI]

RESIDENTIAL WEATHERIZATION SPECIFICATIONS August 30, 2011 Index to Sections Section Page I. GENERAL............................................................................................35 #12;1 I. GENERAL SPECIFICATIONS 1. These specifications apply to existing residential (retro

387

Better Buildings Residential Network Orientation Peer Exchange...  

Broader source: Energy.gov (indexed) [DOE]

Better Buildings Residential Network Orientation Peer Exchange Webinar Better Buildings Residential Network Orientation Peer Exchange Webinar September 11, 2014 7:00PM to 8:3...

388

Building America Residential Buildings Energy Efficiency Meeting...  

Broader source: Energy.gov (indexed) [DOE]

Residential Buildings Energy Efficiency Meeting: July 2010 Building America Residential Buildings Energy Efficiency Meeting: July 2010 On this page, you may link to the summary...

389

Quality Assurance for Residential Retrofit Programs | Department...  

Broader source: Energy.gov (indexed) [DOE]

Quality Assurance for Residential Retrofit Programs Quality Assurance for Residential Retrofit Programs Blue version of the EERE PowerPoint template, for use with PowerPoint 2007....

390

Residential Waste Do not mix in  

E-Print Network [OSTI]

Residential Waste Do not mix in Newspaper Cardboard Paper ScrapsMagazines and Miscellaneous Paper Experiment-Relatedand ResidentialWastebyType #12;

Nakamura, Iku

391

Refrigerant charge management in a heat pump water heater  

DOE Patents [OSTI]

Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.

Chen, Jie; Hampton, Justin W.

2014-06-24T23:59:59.000Z

392

PhD student in Energy Technology, specifically in Commercial refrigeration systems with CO2 as refrigerant  

E-Print Network [OSTI]

the use of carbon dioxide as refrigerant in supermarket refrigeration systems. The work includes fieldPhD student in Energy Technology, specifically in Commercial refrigeration systems with CO2 a PhD student in Energy Technology, specifically Commercial refrigeration systems with CO2

Kazachkov, Ivan

393

Proceedings: commercial refrigeration research workshop. Summary  

SciTech Connect (OSTI)

The purpose of this workshop was to identify the state-of-the-art and determine research needs for improving energy use and demand in commercial refrigeration applications. Workshop attendees included research and development, technical operations and marketing people from manufacturers of supermarket refrigeration, space conditioning, and energy management systems equipment, and from supermarket chains and electric utilities. Presentations were given on best current practice and research needs from the perspective of each of these industry segments. Working groups identified ten important research, development and equipment demonstration projects to improve the efficiency of refrigerating equipment, heating, ventilating and air-conditioning (HVAC) equipment, and other energy-using systems in supermarkets.

Blatt, M.H.

1984-10-01T23:59:59.000Z

394

Status of not-in-kind refrigeration technologies for household space conditioning, water heating and food refrigeration  

SciTech Connect (OSTI)

This paper presents a review of the next generation not-in-kind technologies to replace conventional vapor compression refrigeration technology for household applications. Such technologies are sought to provide energy savings or other environmental benefits for space conditioning, water heating and refrigeration for domestic use. These alternative technologies include: thermoacoustic refrigeration, thermoelectric refrigeration, thermotunneling, magnetic refrigeration, Stirling cycle refrigeration, pulse tube refrigeration, Malone cycle refrigeration, absorption refrigeration, adsorption refrigeration, and compressor driven metal hydride heat pumps. Furthermore, heat pump water heating and integrated heat pump systems are also discussed due to their significant energy saving potential for water heating and space conditioning in households. The paper provides a snapshot of the future R&D needs for each of the technologies along with the associated barriers. Both thermoelectric and magnetic technologies look relatively attractive due to recent developments in the materials and prototypes being manufactured.

Bansal, Pradeep [ORNL; Vineyard, Edward Allan [ORNL; Abdelaziz, Omar [ORNL

2012-01-01T23:59:59.000Z

395

E-Print Network 3.0 - absorption-recompression refrigeration...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

REFRIGERATION CYCLE ACTUAL VAPOR-COMPRESSION REFRIGERATION CYCLE VAPOR-COMPRESSION HEAT PUMPS THE EXERGY... and Engineering Center CARNOT REFRIGERATION CYCLE Practical...

396

E-Print Network 3.0 - amr refrigeration cycle Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

COPs, pressure ratios, outlet temperatures of the refrigerants... , Ltd. KEY WORDS: refrigeration; refrigerants; water; comparison; compressor; cycle; heat pump; air... be...

397

Energy use of icemaking in domestic refrigerators  

SciTech Connect (OSTI)

This study was designed to develop and test a procedure to measure the electrical consumption of ice making in domestic refrigerators. The Department of Energy (DOE) test procedure was modified to include the energy used for icemaking in conventional refrigerators and those equipped with automatic icemakers. The procedure assumed that 500 grams of ice would be produced daily. Using the new test procedure and the existing DOE test (as a benchmark), four refrigerators equipped with automatic icemakers were tested for ice-making energy use. With the revised test, gross electricity consumption increased about 10% (100 kWh/yr) due to automatic icemaking but about 5% (55 kWh/yr) could be attributed to the special features of the automatic icemaker. The test also confirmed the feasibility of establishing procedures for measuring energy use of specific loads and other activities related to domestic refrigerators. Field testing and subsequent retesting revealed a 14% increase in energy use.

Meier, A. [Lawrence Berkeley National Lab., CA (United States). Energy and Environment Div.; Martinez, M.S. [ENVEST-SCE, Irwindale, CA (United States)

1996-02-01T23:59:59.000Z

398

Of Refrigerators & Regulations | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Regulations Of Refrigerators & Regulations February 8, 2011 - 9:29am Addthis Jesse Lee White House Director of Online Affairs Editor's Note: This entry has been cross-posted from...

399

Refrigeration system having standing wave compressor  

DOE Patents [OSTI]

A compression-evaporation refrigeration system, wherein gaseous compression of the refrigerant is provided by a standing wave compressor. The standing wave compressor is modified so as to provide a separate subcooling system for the refrigerant, so that efficiency losses due to flashing are reduced. Subcooling occurs when heat exchange is provided between the refrigerant and a heat pumping surface, which is exposed to the standing acoustic wave within the standing wave compressor. A variable capacity and variable discharge pressure for the standing wave compressor is provided. A control circuit simultaneously varies the capacity and discharge pressure in response to changing operating conditions, thereby maintaining the minimum discharge pressure needed for condensation to occur at any time. Thus, the power consumption of the standing wave compressor is reduced and system efficiency is improved.

Lucas, Timothy S. (Glen Allen, VA)

1992-01-01T23:59:59.000Z

400

International Refrigeration: Proposed Penalty (2012-CE-1510)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that International Refrigeration Products failed to certify a various room air conditioners as compliant with the applicable energy conservation standards.

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Refrigerator Manufacturers: Proposed Penalty (2013-CE-5341)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that Refrigerator Manufacturers, LLC failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards.

402

Improving Industrial Refrigeration System Efficiency - Actual Applications  

E-Print Network [OSTI]

cycle cooling during winter operation, compressor intercooling, direct refrigeration vs. brine cooling, insulation of cold piping to reduce heat gain, multiple screw compressors for improved part load operation, evaporative condensers for reduced system...

White, T. L.

1980-01-01T23:59:59.000Z

403

Cospolich Refrigerator: Proposed Penalty (2013-CE-5314)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that Cospolich Refrigerator Co, Inc. failed to certify walk-in cooler or freezer components as compliant with the energy conservation standards.

404

National Residential Efficiency Measures Database  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

The National Residential Efficiency Measures Database is a publicly available, centralized resource of residential building retrofit measures and costs for the U.S. building industry. With support from the U.S. Department of Energy, NREL developed this tool to help users determine the most cost-effective retrofit measures for improving energy efficiency of existing homes. Software developers who require residential retrofit performance and cost data for applications that evaluate residential efficiency measures are the primary audience for this database. In addition, home performance contractors and manufacturers of residential materials and equipment may find this information useful. The database offers the following types of retrofit measures: 1) Appliances, 2) Domestic Hot Water, 3) Enclosure, 4) Heating, Ventilating, and Air Conditioning (HVAC), 5) Lighting, 6) Miscellaneous.

405

ASHRAE and residential ventilation  

SciTech Connect (OSTI)

In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality creates health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the logical place to provide leadership. This leadership has been demonstrated most recently by the publication of the first nationally recognized standard on ventilation in homes, ASHRAE Standard 62.2-2003, which builds on work that has been part of ASHRAE for many years and will presumably continue. Homeowners and occupants, which includes virtually all of us, will benefit from the application of Standard 62.2 and use of the top ten list. This activity is exactly the kind of benefit to society that the founders of ASHRAE envisioned and is consistent with ASHRAE's mission and vision. ASHRAE members should be proud of their Society for taking leadership in residential ventilation.

Sherman, Max H.

2003-10-01T23:59:59.000Z

406

Residential propane price decreases  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassive Solar HomePromisingStories »Submitter A Bheatingpropane6, 2014 Residential

407

Residential propane price decreases  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassive Solar HomePromisingStories »Submitter A Bheatingpropane6, 2014 Residential05,

408

ARI delegation to Japan on Alternative Refrigerants  

SciTech Connect (OSTI)

Researchers from ARI member companies spoke at the International Conference on Alternative Refrigerants in Tokyo and visited several Japanese organizations for the purpose of exchanging information on alternative refrigerants. The specific purpose of the meetings was to review the methods being utilized to screen alternatives to CFCs and HCFCs: materials compatibility screening methods, lubricant testing techniques, as well as flammability studies. A list of papers presented at the conference is included.

Not Available

1993-02-01T23:59:59.000Z

409

Combined cold compressor/ejector helium refrigerator  

DOE Patents [OSTI]

A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

Brown, D.P.

1984-06-05T23:59:59.000Z

410

Combined cold compressor/ejector helium refrigerator  

DOE Patents [OSTI]

A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

Brown, Donald P. (Southold, NY)

1985-01-01T23:59:59.000Z

411

Energy Efficient Operation of Ammonia Refrigeration Systems  

SciTech Connect (OSTI)

Ammonia refrigeration systems typically offer many energy efficiency opportunities because of their size and complexity. This paper develops a model for simulating single-stage ammonia refrigeration systems, describes common energy saving opportunities, and uses the model to quantify those opportunities. The simulation model uses data that are typically available during site visits to ammonia refrigeration plants and can be calibrated to actual consumption and performance data if available. Annual electricity consumption for a base-case ammonia refrigeration system is simulated. The model is then used to quantify energy savings for six specific energy efficiency opportunities; reduce refrigeration load, increase suction pressure, employ dual suction, decrease minimum head pressure set-point, increase evaporative condenser capacity, and reclaim heat. Methods and considerations for achieving each saving opportunity are discussed. The model captures synergistic effects that result when more than one component or parameter is changed. This methodology represents an effective method to model and quantify common energy saving opportunities in ammonia refrigeration systems. The results indicate the range of savings that might be expected from common energy efficiency opportunities.

Mohammed, Abdul Qayyum [University of Dayton, Ohio] [University of Dayton, Ohio; Wenning, Thomas J [ORNL] [ORNL; Sever, Franc [University of Dayton, Ohio] [University of Dayton, Ohio; Kissock, Professor Kelly [University of Dayton, Ohio] [University of Dayton, Ohio

2013-01-01T23:59:59.000Z

412

Energy Optimization (Electric)- Residential Efficiency Program  

Broader source: Energy.gov [DOE]

The Energy Optimization Programs, administered by WECC, provides residential electric incentives for the following Michigan utilities:

413

Energy Efficiency Evaluation of Refrigeration Technologies in Combined Cooling, Heating and Power Systems  

E-Print Network [OSTI]

With development of absorption refrigeration technology, the cooling requirement can be met using various optional refrigeration technologies in a CCHP system, including compression refrigeration, steam double-effect absorption refrigeration, steam...

Zuo, Z.; Hu, W.

2006-01-01T23:59:59.000Z

414

Residential Forced Air System Cabinet Leakage and Blower Performance  

E-Print Network [OSTI]

CA.   CEC (2008b).  Residential Alternative Calculation Standard for Air Handlers in Residential Space Conditioning of Standards Options for Residential Air Handler Fans.   

Walker, Iain S.

2010-01-01T23:59:59.000Z

415

Financing Non-Residential Photovoltaic Projects: Options and Implications  

E-Print Network [OSTI]

of panel titled “Financing Residential and Small CommercialL ABORATORY Financing Non-Residential Photovoltaic Projects:1 2. Policy Support for Non-Residential PV

Bolinger, Mark

2009-01-01T23:59:59.000Z

416

Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems  

E-Print Network [OSTI]

Rudd. 2007. Review of residential ventilation technologies.2009. EISG Final Report: Residential Integrated VentilationDesign and Operation of Residential Cooling Systems. Proc.

Sherman, Max H.

2011-01-01T23:59:59.000Z

417

Residential implementation of critical-peak pricing of electricity  

E-Print Network [OSTI]

L.R. Modeling alternative residential peak-load electricitydemand response to residential critical peak pricing (CPP)analysis of California residential customer response to

Herter, Karen

2006-01-01T23:59:59.000Z

418

Modeling diffusion of electrical appliances in the residential sector  

E-Print Network [OSTI]

Efficiency Standards in the Residential Electricity Sector.France. USDOE (2001). Residential Energy Consumption Survey,long-term response of residential cooling energy demand to

McNeil, Michael A.

2010-01-01T23:59:59.000Z

419

Guide to Benchmarking Residential Program Progress Webcast Slides...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Guide to Benchmarking Residential Program Progress Webcast Slides Guide to Benchmarking Residential Program Progress Webcast Slides Slides from "Guide to Benchmarking Residential...

420

Highly Insulating Residential Windows Using Smart Automated Shading...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Highly Insulating Residential Windows Using Smart Automated Shading Highly Insulating Residential Windows Using Smart Automated Shading Addthis 1 of 3 Residential Smart Window with...

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Focus Series: Maine-Residential Direct Install Program | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Maine-Residential Direct Install Program Focus Series: Maine-Residential Direct Install Program Better Buildings Neighborhood Program Focus Series: MAINE-Residential Direct Install...

422

Better Buildings Residential Network: Lessons Learned: Peer Exchange...  

Energy Savers [EERE]

Better Buildings Residential Network: Lessons Learned: Peer Exchange Calls Better Buildings Residential Network: Lessons Learned: Peer Exchange Calls Better Buildings Residential...

423

About the Better Buildings Residential Network | Department of...  

Office of Environmental Management (EM)

About the Better Buildings Residential Network About the Better Buildings Residential Network The Better Buildings Residential Network connects energy efficiency programs and...

424

Residential Retrofit Design Guide Overview | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Residential Retrofit Design Guide Overview Residential Retrofit Design Guide Overview Residential Retrofit Design Guide Overview Webinar. Res Retro Design Guide Webinar 5-3-11...

425

Jasper County REMC- Residential Residential Energy Efficiency Rebate Program  

Broader source: Energy.gov [DOE]

Jasper County REMC, in conjunction with Wabash Valley Power Association's Power Moves programs, offers a range of rebates to its residential customers for the purchase and installation of energy...

426

E-Print Network 3.0 - active magnetic refrigerator Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: : The Perspectives of Patient and Public Health Organizations Aerosols Air Conditioning and Refrigeration... : Refrigerant Alternatives for Chillers Koichi Watanabe,...

427

INTERNATIONAL COMPARISON OF RESIDENTIAL ENERGY USE: INDICATORS OF RESIDENTIAL ENERGY USE AND EFFICIENCY PART ONE: THE DATA BASE  

E-Print Network [OSTI]

and Analysis of Swedish Residential Energy Use Data 1960-80.1980. International Residential Energy Use and ConservationInternational Comparison of Residential Energy ! Js~. Report

Schipper, L.

2013-01-01T23:59:59.000Z

428

Potential Refrigerants for Power Electronics Cooling  

SciTech Connect (OSTI)

In the past, automotive refrigerants have conventionally been used solely for the purpose of air conditioning. However, with the development of hybrid-electric vehicles and the incorporation of power electronics (PEs) into the automobile, automotive refrigerants are taking on a new role. Unfortunately, PEs have lifetimes and functionalities that are highly dependent on temperature and as a result thermal control plays an important role in the performance of PEs. Typically, PEs are placed in the engine compartment where the internal combustion engine (ICE) already produces substantial heat. Along with the ICE heat, the additional thermal energy produced by PEs themselves forces designers to use different cooling methods to prevent overheating. Generally, heat sinks and separate cooling loops are used to maintain the temperature. Disturbingly, the thermal control system can consume one third of the total volume and may weigh more than the PEs [1]. Hence, other avenues have been sought to cool PEs, including submerging PEs in automobile refrigerants to take advantage of two-phase cooling. The objective of this report is to explore the different automotive refrigerants presently available that could be used for PE cooling. Evaluation of the refrigerants will be done by comparing environmental effects and some thermo-physical properties important to two-phase cooling, specifically measuring the dielectric strengths of potential candidates. Results of this report will be used to assess the different candidates with good potential for future use in PE cooling.

Starke, M.R.

2005-10-24T23:59:59.000Z

429

Quantum heat engines and refrigerators: Continuous devices  

E-Print Network [OSTI]

Quantum thermodynamics supplies a consistent description of quantum heat engines and refrigerators up to the level of a single few level system coupled to the environment. Once the environment is split into three;a hot, cold and work reservoirs a heat engine can operate. The device converts the positive gain into power;where the gain is obtained from population inversion between the components of the device. Reversing the operation transforms the device into a quantum refrigerator. The quantum tricycle, a device connected by three external leads to three heat reservoirs is used as a template for engines and refrigerators. The equation of motion for the heat currents and power can be derived from first principle. Only a global description of the coupling of the device to the reservoirs is consistent with the first and second laws of thermodynamics. Optimisation of the devices leads to a balanced set of parameters where the couplings to the three reservoirs are of the same order and the external driving field is in resonance. When analysing refrigerators special attention is devoted to a dynamical version of the third law of thermodynamics. Bounds on the rate of cooling when approaching the absolute zero are obtained by optimising the cooling current. At low temperature all refrigerators show universal behavior. Restrictions on the system imposed by the dynamical version of the third law are studied.

Ronnie Kosloff; Amikam Levy

2013-10-02T23:59:59.000Z

430

Modeling diffusion of electrical appliances in the residential sector  

SciTech Connect (OSTI)

This paper presents a methodology for modeling residential appliance uptake as a function of root macroeconomic drivers. The analysis concentrates on four major energy end uses in the residential sector: refrigerators, washing machines, televisions and air conditioners. The model employs linear regression analysis to parameterize appliance ownership in terms of household income, urbanization and electrification rates according to a standard binary choice (logistic) function. The underlying household appliance ownership data are gathered from a variety of sources including energy consumption and more general standard of living surveys. These data span a wide range of countries, including many developing countries for which appliance ownership is currently low, but likely to grow significantly over the next decades as a result of economic development. The result is a 'global' parameterization of appliance ownership rates as a function of widely available macroeconomic variables for the four appliances studied, which provides a reliable basis for interpolation where data are not available, and forecasting of ownership rates on a global scale. The main value of this method is to form the foundation of bottom-up energy demand forecasts, project energy-related greenhouse gas emissions, and allow for the construction of detailed emissions mitigation scenarios.

McNeil, Michael A.; Letschert, Virginie E.

2009-11-22T23:59:59.000Z

431

Residential Electricity Demand in China -- Can Efficiency Reverse the Growth?  

SciTech Connect (OSTI)

The time when energy-related carbon emissions come overwhelmingly from developed countries is coming to a close. China has already overtaken the United States as the world's leading emitter of greenhouse gas emissions. The economic growth that China has experienced is not expected to slow down significantly in the long term, which implies continued massive growth in energy demand. This paper draws on the extensive expertise from the China Energy Group at LBNL on forecasting energy consumption in China, but adds to it by exploring the dynamics of demand growth for electricity in the residential sector -- and the realistic potential for coping with it through efficiency. This paper forecasts ownership growth of each product using econometric modeling, in combination with historical trends in China. The products considered (refrigerators, air conditioners, fans, washing machines, lighting, standby power, space heaters, and water heating) account for 90percent of household electricity consumption in China. Using this method, we determine the trend and dynamics of demandgrowth and its dependence on macroeconomic drivers at a level of detail not accessible by models of a more aggregate nature. In addition, we present scenarios for reducing residential consumption through efficiency measures defined at the product level. The research takes advantage of an analytical framework developed by LBNL (BUENAS) which integrates end use technology parameters into demand forecasting and stock accounting to produce detailed efficiency scenarios, thus allowing for a technologically realistic assessment of efficiency opportunities specifically in the Chinese context.

Letschert, Virginie; McNeil, Michael A.; Zhou, Nan

2009-05-18T23:59:59.000Z

432

Residential Solar Water Heating Rebates  

Broader source: Energy.gov [DOE]

New Hampshire offers a rebate for residential solar water-heating systems and solar space-heating systems. The rebate is equal to $1,500 for systems with an annual estimated output of 5.5 MMBTU to...

433

Residential Solar Sales Tax Exemption  

Broader source: Energy.gov [DOE]

New York enacted legislation in July 2005 exempting the sale and installation of residential solar-energy systems from the state's sales and compensating use taxes. The exemption was extended to...

434

Portland's Residential Solar Permitting Guide  

Broader source: Energy.gov [DOE]

This program guide outlines the application and review procedures for obtaining the necessary permit(s) to install a solar energy system for a new or existing residential building. The guide also...

435

Austin Energy's Residential Solar Rate  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Leslie Libby Austin Energy Project Manager 2020 Utility Scale Solar Goal 175 MW 30 MW PPA at Webberville 2020 Distributed Solar Goal 25 MW Residential - 7.0 MW Commercial - 1.4 MW...

436

Residential Renewable Energy Tax Credit  

Broader source: Energy.gov [DOE]

Established by ''The Energy Policy Act of 2005'', the federal tax credit for residential energy property initially applied to solar-electric systems, solar water heating systems and fuel cells. '...

437

Fully portable, highly flexible dilution refrigerator systems for neutron scattering  

E-Print Network [OSTI]

775 Fully portable, highly flexible dilution refrigerator systems for neutron scattering P. A systems developed specifically for neutron scattering environ- ments. The refrigerators are completely relatively recently however, the lowest temperatures available in almost all neutron scattering laboratories

Boyer, Edmond

438

adiabatic demagnetization refrigerator: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

refrigeration, steam... Zuo, Z.; Hu, W. 2006-01-01 287 Energy Savings from Floating Head Pressure in Ammonia Refrigeration Systems Texas A&M University - TxSpace Summary:...

439

Could You Save Money on Your Refrigerator? | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? July 20, 2012 - 4:35pm Addthis Earlier this week, Amanda wrote about how you can save energy...

440

Proposed Methodology for LEED Baseline Refrigeration Modeling (Presentation)  

SciTech Connect (OSTI)

This PowerPoint presentation summarizes a proposed methodology for LEED baseline refrigeration modeling. The presentation discusses why refrigeration modeling is important, the inputs of energy models, resources, reference building model cases, baseline model highlights, example savings calculations and results.

Deru, M.

2011-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Microcomputer Software for Refrigerant Property and Cycle Analysis Calculations  

E-Print Network [OSTI]

the thermodynamic properties of ten fluorocarbon refrigerants, (Rll, R12, R13, R14, R22, R23, Rl13, Rl14, R500, R502) and ammonia in the sub-cooled, saturation, 2-phase, and superheat regions. In the sec tions which follow, the theoretical basis... for each fluorocarbon refrigerant, represent curve fits to existing tabular property data. For both ammonia and the fluorocarbon refrigerants, the equations for the following four basic properties of refrigerants are used. - Liquid density as a...

Bierschenk, J. L.; Strohl, S. T.; Schmidt, P. S.

442

Optimal performance of endoreversible quantum refrigerators  

E-Print Network [OSTI]

The derivation of general performance benchmarks is important in the design of highly optimized heat engines and refrigerators. To obtain them, one may model phenomenologically the leading sources of irreversibility ending up with results which are model-independent, but limited in scope. Alternatively, one can take a simple physical system realizing a thermodynamic cycle and assess its optimal operation from a complete microscopic description. We follow this approach in order to derive the coefficient of performance at maximum cooling rate for \\textit{any} endoreversible quantum refrigerator. At striking variance with the \\textit{universality} of the optimal efficiency of heat engines, we find that the cooling performance at maximum power is crucially determined by the details of the specific system-bath interaction mechanism. A closed analytical benchmark is found for endoreversible refrigerators weakly coupled to unstructured bosonic heat baths: an ubiquitous case study in quantum thermodynamics.

Luis A. Correa; José P. Palao; Gerardo Adesso; Daniel Alonso

2014-11-24T23:59:59.000Z

443

Basics of Low-temperature Refrigeration  

E-Print Network [OSTI]

This chapter gives an overview of the principles of low temperature refrigeration and the thermodynamics behind it. Basic cryogenic processes - Joule-Thomoson process, Brayton process as well as Claude process - are described and compared. A typical helium laboratory refrigerator based on Claude process is used as a typical example of a low-temperature refrigeration system. A description of the hardware components for helium liquefaction is an important part of this paper, because the design of the main hardware components (compressors, turbines, heat exchangers, pumps, adsorbers, etc.) provides the input for cost calculation, as well as enables to estimate the reliability of the plant and the maintenance expenses. All these numbers are necessary to calculate the economics of a low temperature application.

Alekseev, A

2014-01-01T23:59:59.000Z

444

Toxicity Data to Determine Refrigerant Concentration Limits  

SciTech Connect (OSTI)

This report reviews toxicity data, identifies sources for them, and presents resulting exposure limits for refrigerants for consideration by qualified parties in developing safety guides, standards, codes, and regulations. It outlines a method to calculate an acute toxicity exposure limit (ATEL) and from it a recommended refrigerant concentration limit (RCL) for emergency exposures. The report focuses on acute toxicity with particular attention to lethality, cardiac sensitization, anesthetic and central nervous system effects, and other escape-impairing effects. It addresses R-11, R-12, R-22, R-23, R-113, R-114, R-116, R-123, R-124, R-125, R-134, R-134a, R-E134, R-141b, R-142b, R-143a, R-152a, R-218, R-227ea, R-236fa, R-245ca, R-245fa, R-290, R-500, R-502, R-600a, R-717, and R-744. It summarizes additional data for R-14, R-115, R-170 (ethane), R-C318, R-600 (n-butane), and R-1270 (propylene) to enable calculation of limits for blends incorporating them. The report summarizes the data a nd related safety information, including classifications and flammability data. It also presents a series of tables with proposed ATEL and RCL concentrations-in dimensionless form and the latter also in both metric (SI) and inch-pound (IP) units of measure-for both the cited refrigerants and 66 zerotropic and azeotropic blends. They include common refrigerants, such as R-404A, R-407C, R-410A, and R-507A, as well as others in commercial or developmental status. Appendices provide profiles for the cited single-compound refrigerants and for R-500 and R-502 as well as narrative toxicity summaries for common refrigerants. The report includes an extensive set of references.

Calm, James M.

2000-09-30T23:59:59.000Z

445

Reducing the Carbon Footprint of Commercial Refrigeration Systems Using Life Cycle Climate Performance Analysis: From System Design to Refrigerant Options  

SciTech Connect (OSTI)

In this paper, Life Cycle Climate Performance (LCCP) analysis is used to estimate lifetime direct and indirect carbon dioxide equivalent gas emissions of various refrigerant options and commercial refrigeration system designs, including the multiplex DX system with various hydrofluorocarbon (HFC) refrigerants, the HFC/R744 cascade system incorporating a medium-temperature R744 secondary loop, and the transcritical R744 booster system. The results of the LCCP analysis are presented, including the direct and indirect carbon dioxide equivalent emissions for each refrigeration system and refrigerant option. Based on the results of the LCCP analysis, recommendations are given for the selection of low GWP replacement refrigerants for use in existing commercial refrigeration systems, as well as for the selection of commercial refrigeration system designs with low carbon dioxide equivalent emissions, suitable for new installations.

Fricke, Brian A [ORNL] [ORNL; Abdelaziz, Omar [ORNL] [ORNL; Vineyard, Edward Allan [ORNL] [ORNL

2013-01-01T23:59:59.000Z

446

Method and apparatus for de-superheating refrigerant  

DOE Patents [OSTI]

The present invention is an apparatus and method for de-superheating a primary refrigerant leaving a compressor wherein a secondary refrigerant is used between the primary refrigerant to be de-superheated. Reject heat is advantageously used for heat reclaim. 7 figs.

Zess, J.A.; Drost, M.K.; Call, C.J.

1997-11-25T23:59:59.000Z

447

Control method for mixed refrigerant based natural gas liquefier  

DOE Patents [OSTI]

In a natural gas liquefaction system having a refrigerant storage circuit, a refrigerant circulation circuit in fluid communication with the refrigerant storage circuit, and a natural gas liquefaction circuit in thermal communication with the refrigerant circulation circuit, a method for liquefaction of natural gas in which pressure in the refrigerant circulation circuit is adjusted to below about 175 psig by exchange of refrigerant with the refrigerant storage circuit. A variable speed motor is started whereby operation of a compressor is initiated. The compressor is operated at full discharge capacity. Operation of an expansion valve is initiated whereby suction pressure at the suction pressure port of the compressor is maintained below about 30 psig and discharge pressure at the discharge pressure port of the compressor is maintained below about 350 psig. Refrigerant vapor is introduced from the refrigerant holding tank into the refrigerant circulation circuit until the suction pressure is reduced to below about 15 psig, after which flow of the refrigerant vapor from the refrigerant holding tank is terminated. Natural gas is then introduced into a natural gas liquefier, resulting in liquefaction of the natural gas.

Kountz, Kenneth J. (Palatine, IL); Bishop, Patrick M. (Chicago, IL)

2003-01-01T23:59:59.000Z

448

Fast Nonconvex Model Predictive Control for Commercial Refrigeration  

E-Print Network [OSTI]

its capabil- ity to minimize the total cost of energy for a commercial refrigeration system while multi-zone refrigeration system, consisting of several cooling units that share a common compressor. This corresponds roughly to 2% of the entire electricity consumption in the country. Refrigerated goods constitute

449

Literature survey of heat transfer enhancement techniques in refrigeration applications  

SciTech Connect (OSTI)

A survey has been performed of the technical and patent literature on enhanced heat transfer of refrigerants in pool boiling, forced convection evaporation, and condensation. Extensive bibliographies of the technical literature and patents are given. Many passive and active techniques were examined for pure refrigerants, refrigerant-oil mixtures, and refrigerant mixtures. The citations were categorized according to enhancement technique, heat transfer mode, and tube or shell side focus. The effects of the enhancement techniques relative to smooth and/or pure refrigerants were illustrated through the discussion of selected papers. Patented enhancement techniques also are discussed. Enhanced heat transfer has demonstrated significant improvements in performance in many refrigerant applications. However, refrigerant mixtures and refrigerant-oil mixtures have not been studied extensively; no research has been performed with enhanced refrigerant mixtures with oil. Most studies have been of the parametric type; there has been inadequate examination of the fundamental processes governing enhanced refrigerant heat transfer, but some modeling is being done and correlations developed. It is clear that an enhancement technique must be optimized for the refrigerant and operating condition. Fundamental processes governing the heat transfer must be examined if models for enhancement techniques are to be developed; these models could provide the method to optimize a surface. Refrigerant mixtures, with and without oil present, must be studied with enhancement devices; there is too little known to be able to estimate the effects of mixtures (particularly NARMs) with enhanced heat transfer. Other conclusions and recommendations are offered.

Jensen, M.K.; Shome, B. [Rensselaer Polytechnic Inst., Troy, NY (United States). Dept. of Mechanical Engineering, Aeronautical Engineering and Mechanics

1994-05-01T23:59:59.000Z

450

Form Date 4/4/01 Refrigerant Service Order Form  

E-Print Network [OSTI]

Recovery Unit ID # : Added Lbs oz Lbs oz Lbs oz Startup Charge Net Refrigerant Added: Lbs oz Parts UsedForm Date 4/4/01 Refrigerant Service Order Form Service ID: Owner: Work Order #: Building: Date: Issued: Completed: Equipment ID: Technicians: Location: Model: Manufact: Serial #: Refrigerant Type

Russell, Lynn

451

Feasibility of Solar-Assisted Refrigerated Transport in Australia  

E-Print Network [OSTI]

systems. Keywords: refrigeration, transport, photovoltaics, economics. 1 #12;B. Elliston, M. Dennis) modules to minimise the use of diesel generation in refrigerated transport. Sub- sequently, UK supermarket. This report investigates the merit of retrofitting a PV system to assist refrigerated trailers in Australian

452

Helium refrigeration considerations for cryomodule design  

SciTech Connect (OSTI)

Many of the present day accelerators are based on superconducting radio frequency (SRF) cavities, packaged in cryo-modules (CM), which depend on helium refrigeration at sub-atmospheric pressures, nominally 2 K. These specialized helium refrigeration systems are quite cost intensive to produce and operate. Particularly as there is typically no work extraction below the 4.5-K supply, it is important that the exergy loss between this temperature level and the CM load temperature(s) be minimized by the process configuration choices. This paper will present, compare and discuss several possible helium distribution process arrangements to support the CM loads.

Ganni, V.; Knudsen, P. [Thomas Jefferson National Accelerator Facility (JLab), Newport News, VA 23606 (United States)

2014-01-29T23:59:59.000Z

453

PROGRESS IN RESIDENTIAL ENERGY CONSERVATION - A MULTI COUNTRY PERSPECTIVE -  

E-Print Network [OSTI]

Conference, "New Energy Conservation Technologies", Berlin,IN RESIDENTIAL ENERGY CONSERVATION - A MULTI COUNTRYIN RESIDENTIAL ENERGY CONSERVATION - A MULTI COUNTRY

Schipper, Lee

2013-01-01T23:59:59.000Z

454

Floating Loop System For Cooling Integrated Motors And Inverters Using Hot Liquid Refrigerant  

DOE Patents [OSTI]

A floating loop vehicle component cooling and air-conditioning system having at least one compressor for compressing cool vapor refrigerant into hot vapor refrigerant; at least one condenser for condensing the hot vapor refrigerant into hot liquid refrigerant by exchanging heat with outdoor air; at least one floating loop component cooling device for evaporating the hot liquid refrigerant into hot vapor refrigerant; at least one expansion device for expanding the hot liquid refrigerant into cool liquid refrigerant; at least one air conditioning evaporator for evaporating the cool liquid refrigerant into cool vapor refrigerant by exchanging heat with indoor air; and piping for interconnecting components of the cooling and air conditioning system.

Hsu, John S [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN; Coomer, Chester [Knoxville, TN; Marlino, Laura D [Oak Ridge, TN

2006-02-07T23:59:59.000Z

455

Energy Efficiency Program for Residential Products: Energy Conservation Standards for Residential Dishwashers, Reopening of the Comment Period  

Broader source: Energy.gov [DOE]

Energy Efficiency Program for Residential Products: Energy Conservation Standards for Residential Dishwashers, Reopening of the Comment Period

456

Residential Transactive Control Demonstration  

SciTech Connect (OSTI)

Arguably the most exciting aspect of the smart grid vision is the full participation of end-use resources with all forms of generation and energy storage in the reliable and efficient operation of an electric power system. Engaging all of these resources in a collaborative manner that respects the objectives of each resource, is sensitive to the system and local constraints of electricity flow, and scales to the large number of devices and systems participating is a grand challenge. Distributed decision-making system approaches have been presented and experimentation is underway. This paper reports on the preliminary findings of a residential demand response demonstration that uses the bidding transactions of supply and end-use air conditioning resources communicating with a real-time, 5 minute market to balance the various needs of the participants on a distribution feeder. The nature of the demonstration, the value streams being explored, and the operational scenarios implemented to characterize the system response are summarized along with preliminary findings.

Widergren, Steven E.; Fuller, Jason C.; Marinovici, Maria C.; Somani, Abhishek

2014-02-19T23:59:59.000Z

457

EA-1871: Environmental Assessment for Final Rule, 10 CFR 433, “EE Standards for New Federal Commercial and High-Rise Multi-Family Residential Buildings” and 10 CFR 435, “EE Standards for New Federal Residential Low-Rise Residential Buildings"  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy (DOE) has prepared this Environmental Assessment (EA) for DOE‘s Final Rule, 10 CFR 433, ?Energy Efficiency Standards for New Federal Commercial and High-Rise Multi-Family Residential Buildings? and 10 CFR 435, ?Energy Efficiency Standards for New Federal Residential Low-Rise Residential Buildings? Baseline Standards Update. The final rule updates the baseline standards in 10 CFR 433 and 10 CFR 435 to the latest private sector standards based on the cost-effectiveness of the latest private sector standards and DOE‘s determination that energy efficiency has been improved in these codes as required by 42 U.S.C 6831 et seq. DOE is issuing its final determinations on American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2007 (ASHRAE 2007) and the International Code Council‘s 2009 International Energy Conservation Code (IECC) in the same edition of the Federal Register as this final rule.

458

Similar effects of residential and non-residential vegetation on bird diversity in suburban neighbourhoods  

E-Print Network [OSTI]

Similar effects of residential and non-residential vegetation on bird diversity in suburban the Queen in Right of Canada 2013 Abstract Estimating the relative importance of vegetation on residential land (gardens, yards, and street-trees) and vegetation on non-residential land (parks and other large

Dawson, Jeff W.

459

Wave Impact Study on a Residential Building Wave Impact Study on a Residential Building  

E-Print Network [OSTI]

Wave Impact Study on a Residential Building Paper: Wave Impact Study on a Residential Building John residential light- frame wood buildings and wave and surge loading be- cause often little is left residential structures and wave loading. To do this, one-sixth scale residen- tial building models typical

Cox, Dan

460

2008 Residential2008 Residential Energy Plan ReviewEnergy Plan Reviewe gy la eviewe gy la eview  

E-Print Network [OSTI]

2008 Residential2008 Residential Energy Plan ReviewEnergy Plan Reviewe gy la eviewe gy la eview #12;2008 Residential Energy Plan2008 Residential Energy Plan Review ChecklistReview Checklist Simplification ChecklistsOther Available Checklists 2005 and 2008 Residential Energy Documentation2005 and 2008 Residential

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Waste Heat Recapture from Supermarket Refrigeration Systems  

SciTech Connect (OSTI)

The objective of this project was to determine the potential energy savings associated with improved utilization of waste heat from supermarket refrigeration systems. Existing and advanced strategies for waste heat recovery in supermarkets were analyzed, including options from advanced sources such as combined heat and power (CHP), micro-turbines and fuel cells.

Fricke, Brian A [ORNL

2011-11-01T23:59:59.000Z

462

Covered Product Category: Refrigerated Beverage Vending Machines  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including refrigerated beverage vending machines, which are covered by the ENERGY STAR® program. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

463

Alternative Refrigerants for Building Air Conditioning  

E-Print Network [OSTI]

The majority of building air conditioning has traditionally been achieved with vapor compression technology using CFC-I I or HCFC-22 as refrigerant fluids. CFC-11 is being successfully replaced by HCFC-123 (retrofit or new equipment) or by HFC- 134a...

Bivens, D. B.

1996-01-01T23:59:59.000Z

464

Ground Loops for Heat Pumps and Refrigeration  

E-Print Network [OSTI]

Ground loops are used for water source heat pumps. Refrigeration can be put on a ground loop. Water-cooled condensing units are more efficient than air-cooled, and they can be put indoors. Indoor location makes piping for desuperheater hot water...

Braud, H. J.

1986-01-01T23:59:59.000Z

465

Piedmont Natural Gas- Residential Equipment Efficiency Program  

Broader source: Energy.gov [DOE]

Piedmont Natural Gas offers rebates on high-efficiency natural gas tankless water heaters, tank water heaters and furnaces. Customers on the 201-Residential Service Rate or 221-Residential Service...

466

Edmond Electric- Residential Heat Pump Rebate Program  

Broader source: Energy.gov [DOE]

Edmond Electric offers rebates to residential customers who install energy-efficient heat pumps. This program applies to installations in both new and existing residential homes and complexes. Air...

467

Residential Load Management Program and Pilot  

E-Print Network [OSTI]

In 1986 LCRA embarked on residential load management to control peak summer loads. At that time, LCRA was considered a summer peaking utility, and residential air conditioning and water heating systems were selected for control. The program...

Haverlah, D.; Riordon, K.

1994-01-01T23:59:59.000Z

468

Charlotte Green Supply Chain: Residential Retrofitting | Department...  

Broader source: Energy.gov (indexed) [DOE]

Charlotte Green Supply Chain: Residential Retrofitting Charlotte Green Supply Chain: Residential Retrofitting July 30, 2010 - 10:50am Addthis Joshua DeLung What does this mean for...

469

BINGHAMTON UNIVERSITY OFFICE OF RESIDENTIAL LIFE  

E-Print Network [OSTI]

BINGHAMTON UNIVERSITY OFFICE OF RESIDENTIAL LIFE PROCEDURES FOR THE USE OF HOLIDAY DECORATIONS in a location established by the Office of Residential Life. In these instances, candles and incense may never

Suzuki, Masatsugu

470

BINGHAMTON UNIVERSITY OFFICE OF RESIDENTIAL LIFE  

E-Print Network [OSTI]

BINGHAMTON UNIVERSITY OFFICE OF RESIDENTIAL LIFE PROCEDURES FOR THE USE OF HOLIDAY DECORATIONS by the Office of Residential Life. In these instances, candles and incense may never be left unattended and any

Suzuki, Masatsugu

471

CC: Security, Residential Life Evacuation Assistance Form  

E-Print Network [OSTI]

CC: Security, Residential Life Evacuation Assistance Form Voluntary Self-Identification If you have will be kept confidential and used only by Environmental Health and Safety, Residential Life (if applicable

Mahon, Bradford Z.

472

Department of Residential Life University of Missouri  

E-Print Network [OSTI]

Department of Residential Life University of Missouri may 11 >> halls close, 5 p.m. summer to June 1). Sign up forms are available at 0780 Defoe-Graham in the Residential Life Administration Office

Taylor, Jerry

473

Residential Properties 5100 South Dorchester Avenue  

E-Print Network [OSTI]

Residential Properties 5100 South Dorchester Avenue Chicago, Illinois 60615 T 773.753-2200 F 733 for specific answers to: residential@uchicago.edu. Thank you, in advance, for your patience during this process

He, Chuan

474

Retail refrigeration systems -- The use of ammonia and two-level secondary refrigeration  

SciTech Connect (OSTI)

The concept of a secondary refrigeration system for high-temperature use as investigated in 1991, and a design for a full high-temperature system was completed the following year. In late 1992, a supermarket chain commissioned a study of the feasibility of turning the design into a practical application and assisted the project in 1993 by commissioning a test facility for single-temperature secondary refrigeration at one of the company`s factory sites. Results and conclusions from this trial work pointed toward the need for a total secondary refrigeration system, including a low-temperature system for frozen food display cases, and the possibility of utilizing environmentally friendly ammonia as the primary refrigerant. Therefore, in late 1993/early 1994, a low-temperature system was developed and commissioned at the test facility. Full collaboration between the supermarket company and the contractor resulted in the funding of practical trial work and feasibility studies for both secondary refrigeration and a fully detailed proposal for the use of ammonia in a public retail environment. In May 1995, the first UK ammonia and two-level secondary refrigeration system began operation in a supermarket in Horsham, Sussex England.

Thomas, A.S. [Westward Refrigeration, Gloucester (United Kingdom)

1998-10-01T23:59:59.000Z

475

Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study  

SciTech Connect (OSTI)

The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

Piotr A. Domanski; W. Vance Payne

2002-10-31T23:59:59.000Z

476

Dilution cycle control for an absorption refrigeration system  

DOE Patents [OSTI]

A dilution cycle control system for an absorption refrigeration system is disclosed. The control system includes a time delay relay for sensing shutdown of the absorption refrigeration system and for generating a control signal only after expiration of a preselected time period measured from the sensed shutdown of the absorption refrigeration system, during which the absorption refrigeration system is not restarted. A dilution cycle for the absorption refrigeration system is initiated in response to generation of a control signal by the time delay relay. This control system is particularly suitable for use with an absorption refrigeration system which is frequently cycled on and off since the time delay provided by the control system prevents needless dilution of the absorption refrigeration system when the system is turned off for only a short period of time and then is turned back on.

Reimann, Robert C. (Lafayette, NY)

1984-01-01T23:59:59.000Z

477

Energy efficiency standards for eight consumer products: public meeting clarification, questions and answers  

SciTech Connect (OSTI)

Eighteen corporations and manufacturers provided answers to many questions posed at a public meeting on energy efficiency standards for eight consumer products. Questions on the regulations concerning the manufacturing standards, performance standards, and testing standards are included. Questions were posed about air conditioners, refrigerators, refrigerator-freezers, stoves (ranges), ovens, clothes dryers, oil fired burners, water heaters, furnaces, etc. A presentation containing information pertaining to the values of average annual energy consumption per unit used by DOE in its analysis leading to proposed energy efficiency standards for nine types of consumer products is included. (MCW)

None

1980-08-01T23:59:59.000Z

478

E-Print Network 3.0 - america residential system Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Services Housing, Dining & Residential Services Housing, Dining... & Residential Services Housing, Dining & Residential ... Source: Balandin, Alexander- Department of...

479

System design and dynamic signature identification for intelligent energy management in residential buildings.  

E-Print Network [OSTI]

for Intelligent Energy Management in Residential Buildingsfor Intelligent Energy Management in Residential Buildingsthat can provide autonomous energy management to residential

Jang, Jaehwi

2008-01-01T23:59:59.000Z

480

IEA Annex 26: Advanced Supermarket Refrigeration/Heat Recovery Systems  

SciTech Connect (OSTI)

With increased concern about the impact of refrigerant leakage on global warming, a number of new supermarket refrigeration system configurations requiring significantly less refrigerant charge are being considered. In order to help promote the development of advanced systems and expand the knowledge base for energy-efficient supermarket technology, the International Energy Agency (IEA) established IEA Annex 26 (Advanced Supermarket Refrigeration/Heat Recovery Systems) under the ''IEA Implementing Agreement on Heat Pumping Technologies''. Annex 26 focuses on demonstrating and documenting the energy saving and environmental benefits of advanced systems design for food refrigeration and space heating and cooling for supermarkets. Advanced in this context means systems that use less energy, require less refrigerant and produce lower refrigerant emissions. Stated another way, the goal is to identify supermarket refrigeration and HVAC technology options that reduce the total equivalent warming impact (TEWI) of supermarkets by reducing both system energy use (increasing efficiency) and reducing total refrigerant charge. The Annex has five participating countries: Canada, Denmark, Sweden, the United Kingdom, and the United States. The working program of the Annex has involved analytical and experimental investigation of several candidate system design approaches to determine their potential to reduce refrigerant usage and energy consumption. Advanced refrigeration system types investigated include the following: distributed compressor systems--small parallel compressor racks are located in close proximity to the food display cases they serve thus significantly shortening the connecting refrigerant line lengths; secondary loop systems--one or more central chillers are used to refrigerate a secondary coolant (e.g. brine, ice slurry, or CO2) that is pumped to the food display cases on the sales floor; self-contained display cases--each food display case has its own refrigeration unit; low-charge direct expansion--similar to conventional multiplex refrigeration systems but with improved controls to limit charge. Means to integrate store HVAC systems for space heating/cooling with the refrigeration system have been investigated as well. One approach is to use heat pumps to recover refrigeration waste heat and raise it to a sufficient level to provide for store heating needs. Another involves use of combined heating and power (CHP) or combined cooling, heating, and power (CCHP) systems to integrate the refrigeration, HVAC, and power services in stores. Other methods including direct recovery of refrigeration reject heat for space and water heating have also been examined.

Baxter, VAN

2003-05-19T23:59:59.000Z

Note: This page contains sample records for the topic "residential refrigerators refrigerator-freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Children in Residential Care: A wicked problem?  

E-Print Network [OSTI]

#12;Children in Residential Care: A wicked problem? Mary McKenna Flinders Law School 29 Nov 11 Mary in residential care · At what level of the system should changes occur? · Numbers in residential care in SA-discovery of child abuse in 1970s · Legislation & policy changes · Reporting and investigation · Types of abuse #12

482

Renovating Residential HVAC Systems HVAC Systems  

E-Print Network [OSTI]

- 1 - LBNL 57406 Renovating Residential HVAC Systems HVAC Systems J.A. McWilliams and I.S. Walker and Air Conditioning), and Stacy Hunt and Ananda Harzell (IBACOS). #12;- 3 - Renovating Residential HVAC Guideline for Residential HVAC Retrofits (http

483

living and learning Department of Residential Life  

E-Print Network [OSTI]

living and learning Accessible housing at Mizzou Department of Residential Life University is important to us. The Department of Residential Life at MU is committed to providing and improving accessible spaces for students with disabilities. Residential Life will help provide appropriate housing

Missouri-Columbia, University of

484

Residential Building Stockg Assessment (RBSA)for  

E-Print Network [OSTI]

9/4/2013 1 Residential Building Stockg Assessment (RBSA)for Multi-Family Housing Tom Eckman Objectives Characterize Residential Sector Building Stock ­ Single Family (Four-plex and below) l if il ( i Pacific Northwest Residential Energy Survey (PNWRES92)Survey (PNWRES92) NEEA Survey of Baseline

485

CC: Security, Residential Life Evacuation Assistance Form  

E-Print Network [OSTI]

CC: Security, Residential Life Evacuation Assistance Form Voluntary Self-Identification If you have will be kept confidential and used only by Environmental Health and Safety, Residential Life (if applicable:_______________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ #12;CC: Security, Residential Life If this is a temporary request, please provide a date when

Cantlon, Jessica F.

486

Housing & Residential Life Contracts, Assignments & Billing  

E-Print Network [OSTI]

Housing & Residential Life Contracts, Assignments & Billing Comstock Hall-East 210 Delaware St. SE.housing.umn.edu/contractbook. I hereby agree to comply with all University of Minnesota and Housing & Residential Life policies to promptly notify Housing & Residential Life of any felony or misdemeanor charge or conviction prior

Amin, S. Massoud

487

Residential Life Luggage Program Summer 2014  

E-Print Network [OSTI]

Residential Life Luggage Program Summer 2014 International and out-of-state students who should be addressed as follows: Residential Life Luggage Program Physical Plant/CDS University. · Residential Life will not be held responsible for items lost or damaged in handling. We advise against sending

Massachusetts at Amherst, University of

488

Graduate Hall Director Office of Residential Programs  

E-Print Network [OSTI]

Page 1 Graduate Hall Director Office of Residential Programs Housing Guidelines #12;Page 2 Graduate Hall Director for Residential Programs Guidelines for Residence This document is intended for the Office of Residential Programs Graduate Hall Directors (GHDs) who obtain housing on campus as part

Hone, James

489

NORTHWESTERN UNIVERSITY DEPARTMENT OF RESIDENTIAL SERVICES  

E-Print Network [OSTI]

NORTHWESTERN UNIVERSITY DEPARTMENT OF RESIDENTIAL SERVICES FALL 2013/WINTER 2014/SPRING 2014 of the Contract by the Executive Director of Residential Services ("Director") or their designee and receipt for residence in the premises, I am responsible to advise the Department of Residential Services immediately

Reber, Paul J.

490

Housing & Residential Life Contracts, Assignments & Billing  

E-Print Network [OSTI]

Housing & Residential Life Contracts, Assignments & Billing Comstock Hall-East 210 Delaware St. SE & Residential Life. For the fall semester, I will cancel on or before August 7. For the spring semester, I day until Housing & Residential Life is able to fill my assigned space with a student from the waiting

Minnesota, University of

491

Characterizing Residential Broadband Networks Marcel Dischinger  

E-Print Network [OSTI]

Characterizing Residential Broadband Networks Marcel Dischinger MPI for Software Systems mdischin and rapidly growing proportion of users connect to the Internet via residential broadband networks such as Dig- ital Subscriber Lines (DSL) and cable. Residential networks are often the bottleneck in the last mile

Saroiu, Stefan

492

WARREN RESIDENTIAL LIFE RESIDENT ASSISTANT POSITION DESCRIPTION  

E-Print Network [OSTI]

WARREN RESIDENTIAL LIFE RESIDENT ASSISTANT POSITION DESCRIPTION The position of Resident Assistant for students living within the Warren College residential community. Resident Assistant's (RA's) are principle members of the Warren Residential Life staff. In accordance with the University of California's Personnel

Russell, Lynn

493

Residential Lighting: Title 24 and Technology Update  

E-Print Network [OSTI]

Residential Lighting: Title 24 and Technology Update Best practices in lighting design to comply;INTRODUCTION Course Topics Part 1: Technology Overview · Common lighting terminology · Residential lighting residential lighting regulation · Design examples to reach or exceed code Part 5: Compliance Process · Step

California at Davis, University of

494

Siena College Office of Residential Life  

E-Print Network [OSTI]

Siena College Office of Residential Life New Student Housing Application Instructions #12;Welcome students who are admitted as "Residential" students. Commuters DO NOT need to complete the application for "Residential Life (My Housing)" is under the "Personal Information" Tab #12;Within the "Personal Information

495

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

E-Print Network [OSTI]

Energy Outlook 2012 estimate of 116.1 million households (EIA, 2012), the number of households with wine/

Greenblatt, Jeffery B.

2013-01-01T23:59:59.000Z

496

Energy use of US residential refrigerators and freezers: function derivation based on household and climate characteristics  

E-Print Network [OSTI]

all units in our da- taset. (AHAM) (see Appendix 7-B in DOEownership provided by AHAM (2010, personal communication).in ownership provided by AHAM to weight the RECS ownership

Greenblatt, Jeffery

2013-01-01T23:59:59.000Z

497

Shrewsbury Electric- Residential Energy Efficiency Rebate Program  

Broader source: Energy.gov [DOE]

In collaboration with EFI, Shrewsbury Electric offers rebates on ENERGY STAR appliances. Eligible products include washing machines, dishwashers, refrigerators, and room air conditioners. ...

498

CALIFORNIA ENERGY Residential Duct Placement  

E-Print Network [OSTI]

through the integrated design, construction, and operation of building systems. The Integrated Energy Systems Integrated Design of Commercial Building Ceiling Systems Integrated Design of Residential Ducting;#12;ACKNOWLEDGEMENTS The products and outcomes presented in this report are part of the Integrated Design

499

Comparing Residential Furnace Blowers for  

E-Print Network [OSTI]

of air conditioner performance, standby power, as well as igniter and combustion air blower power results in 10% lower air conditioner efficiency. For heating, the advantage of the BPM blower was to assess the performance of residential furnace blowers for both heating, cooling and air distribution

500

Projected Regional Impacts of Appliance Efficiency Standards for the U.S. Residential Sector  

E-Print Network [OSTI]

standards Other Refrigerators and Freezers DWsandCWs: g aioo%- Other | Refrigerators and Freezers Gas and oil watermarket prices for refrigerators and freezers from 1987 to

Koomey, J.G.

2010-01-01T23:59:59.000Z