Powered by Deep Web Technologies
Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Catalytic conversion of LPG  

Science Conference Proceedings (OSTI)

The low reactivity of light paraffins has long hindered their utilization as petrochemical feedstocks. Except for their use in ethylene crackers, LPG fractions have traditionally been consumed as fuel. New catalytic processes now being commercialized open new avenues for the utilization of LPG as sources of valuable petrochemical intermediates. This paper discusses processes for the dehydrogenation and aromatization of LPG.

Pujado, P.R.; Vora, B.V.; Mowry, J.R.; Anderson, R.F.

1986-01-01T23:59:59.000Z

2

LPG in Venezuela  

SciTech Connect

The use of LPG for domestic consumption in Venezuela began in late 1929 when LPG was imported in lots of 500 cylinders. These cylinders were then returned to the U.S. for refilling. Total consumption at that time was some 40M/sup 3/ (250 barrels) per year and by 1937 had grown to some 540M/sup 3/ (3,400 barrels) per year. Local production of LPG from gas began in the mid thirties with a small cooling plant in the Mene Grande Field in the Lake Maracaibo area, the first field to produce oil in Venezuela (1914). This plant produced gasoline for a refinery and some of the first LPG used in Venezuela for domestic consumption. The capacity of this plant was insufficient to satisfy the growing demand for LPG which was supplied from refinery production until the development of the natural gas processing industry. At the present time, Venezuelan refineries are net consumers of LPG.

Romero, O.

1986-01-01T23:59:59.000Z

3

LPG in Mexico  

SciTech Connect

The authors review LPG in Mexico. They attempt to project numbers to the year 2000 using a supply/demand comparison.

Miles, E.L.

1986-01-01T23:59:59.000Z

4

LPG in Missouri  

SciTech Connect

This study presents a brief history of the LPG industry, the overall consumption and sector usage for both the U.S. and Missouri, the movement and storage of LPG, the future supply and demand, and the identification of various state and federal regulations.

1978-01-01T23:59:59.000Z

5

Make aromatics from LPG  

SciTech Connect

Liquefied petroleum gas (LPG) consists mainly of the propane and butane fraction recovered from gas fields, associated petroleum gas and refinery operations. Apart from its use in steam cracking and stream reforming, LPG has few petrochemical applications. The relative abundance of LPG and the strong demand for aromatics - benzene, toluene and xylenes (BTX) - make it economically attractive to produce aromatics via the aromatization of propane and butanes. This paper describes the Cyclar process, which is based on a catalyst formulation developed by BP and which uses UOP's CCR catalyst regeneration technology, converts propane, butanes or mixtures thereof to petrochemical-quality aromatics in a single step.

Doolan, P.C. (BP Exploration Co. Ltd., London (GB)); Pujado, P.R. (UOP, Des Plaines, IL (US))

1989-09-01T23:59:59.000Z

6

Jet fuel from LPG  

SciTech Connect

Explains how jet fuel can be manufactured from propane and/or butane with attractive rates of return. This scheme is advantageous where large reserves of LPG-bearing gas is available or LPG is in excess. The following sequence of processes in involved: dehydrogenation of propane (and/or butane) to propylene (and/or butylene); polymerization of this monomer to a substantial yield of the desired polymer by recycling undesired polymer; and hydrotreating the polymer to saturate double bonds. An attribute of this process scheme is that each of the individual processes has been practiced commercially. The process should have appeal in those parts of the world which have large reserves of LPG-bearing natural gas but little or no crude oil, or where large excesses of LPG are available. Concludes that economic analysis shows attractive rates of return in a range of reasonable propane costs and product selling prices.

Maples, R.E.; Jones, J.R.

1983-02-01T23:59:59.000Z

7

Propane, Liquefied Petroleum Gas (LPG)  

NLE Websites -- All DOE Office Websites (Extended Search)

Propane: Liquefied Petroleum Gas (LPG) Propane: Liquefied Petroleum Gas (LPG) Ford F-150 (Dual-Fuel LPG) Propane or liquefied petroleum gas (LPG) is a clean-burning fossil fuel that can be used to power internal combustion engines. LPG-fueled vehicles can produce significantly lower amounts of some harmful emissions and the greenhouse gas carbon dioxide (CO2). LPG is usually less expensive than gasoline, it can be used without degrading vehicle performance, and most LPG used in U.S. comes from domestic sources. The availability of LPG-fueled light-duty passenger vehicles is currently limited. A few light-duty vehicles-mostly larger trucks and vans-can be ordered from a dealer with a prep-ready engine package and converted to use propane. Existing conventional vehicles can also be converted for LPG use.

8

LPG | OpenEI  

Open Energy Info (EERE)

LPG LPG Dataset Summary Description The JodiOil World Database is freely available from the Joint Organisations Data Initiative (JODI) and is updated on or around the 20th of each month. Source JODI Date Released October 01st, 2004 (10 years ago) Date Updated March 21st, 2011 (3 years ago) Keywords crude oil diesel fuel oil gasoline kerosene LPG Data application/zip icon Text file, all JODI Database data: Jan 2002 - Jan 2011 (zip, 14.5 MiB) application/pdf icon Definitions of Abbreviations and Codes (pdf, 698.3 KiB) application/pdf icon Column Headings for Dataset (pdf, 13.4 KiB) Quality Metrics Level of Review Some Review Comment Some of the data has "some review" and some of the data has "no review"; the supplemental documentation provides definitions for the assessment codes for each piece of data in the datasets (essentially, 1 = some review, 2 = use with caution, 3 = not reviewed)

9

LPG fuel shutoff system  

SciTech Connect

An LPG fuel shutoff system for use with a vehicle having an LPG fuel engine and having a solenoid valve to supply and shut off LPG fuel is described including: a relay having a relay contact which is closed when an electric current is fed to a coil of the relay; a pressure switch having a first position and a second position and adapted to be in the first position when engine oil pressure rises above a predetermined level; and an oil lamp adapted to light when the engine oil pressure is below the predetermined level, and wherein a solenoid coil of the solenoid valve is connected at one side to a battery through an ignition switch and a fuel switch. The solenoid coil also is connected, at another side of the solenoid coil, in series to the relay contact and the pressure switch in the second position respectively, the coil of the relay is connected to the solenoid valve side of the ignition switch through a starting switch, the oil lamp is connected between the ignition switch and the pressure switch.

Watanabe, T.; Miyata, K.

1988-01-26T23:59:59.000Z

10

The SONATRACH jumbo LPG plant  

SciTech Connect

The authors aim is to give to the 17 TH world gas conference a general idea on SONATRACH LPG PLANT which is located in the ARZEW area. They develop this communication as follows: general presentation of LPG plant: During the communication, the author's will give the assistance all the information concerning the contractions the erection's date and the LPG PLANT process, start-up of the plant: In this chapter, the authors's will describe the start-up condition, the performance test result, the flexibility test result and the total mechanical achievement of the plant; operation by SONATRACH: After the success that obtained during the mechanical achievement and performance test, the contractor handed over the plant to SONATRACH.

Ahmed Khodja, A.; Bennaceur, A.

1988-01-01T23:59:59.000Z

11

LPG storage vessel cracking experience  

SciTech Connect

In order to evaluate liquefied petroleum gas (LPG) handling and storage hazards, Caltex Petroleum Corp. (Dallas) surveyed several installations for storage vessel cracking problems. Cracking was found in approximately one-third of the storage vessels. In most cases, the cracking appeared to be due to original fabrication problems and could be removed without compromising the pressure containment. Several in-service cracking problems found were due to exposure to wet hydrogen sulfide. Various procedures were tried in order to minimize the in-service cracking potential. One sphere was condemned because of extensive subsurface cracking. This article's recommendations concern minimizing cracking on new and existing LPG storage vessels.

Cantwell, J.E. (Caltex Petroleum Corp., P.O. Box 619500, Dallas, TX (US))

1988-10-01T23:59:59.000Z

12

LPG storage vessel cracking experience  

SciTech Connect

As part of an overall company program to evaluate LPG handling and storage hazards the authors surveyed several installations for storage vessel cracking problems. Cracking was found in approximately one third of the storage vessels. In most cases the cracking appeared due to original fabrication problems and could be removed without compromising the pressure containment. Several in-service cracking problems due to exposure to wet hydrogen sulfide were found. Various procedures were tried in order to minimize the in-service cracking potential. One sphere was condemned because of extensive subsurface cracking. Recommendations are made to minimize cracking on new and existing LPG storage vessels.

Cantwell, J.E.

1988-01-01T23:59:59.000Z

13

Improved water-driven lpg slug process  

SciTech Connect

The economics of oil recovery by the LPG-slug process depends upon increasing the sweep efficiency and recovering the injected LPG. There are 2 basic forms of the LPG-slug processes--the gas-driven and the water-driven. The pressure required for miscibility between dry gas and LPG prohibits the use of the gas-driven LPG process in shallow reservoirs. The water-driven LPG slug process normally exhibits good sweep efficiency. However, displacement of the LPG by water is poor. An improvement in this process appears possible by injecting a slug of carbon dioxide between the LPG slug and the water drive. Laboratory experiments were conducted in linear core systems to determine the effect of pressure on the various displacement zones. A displacement test was conducted with LPG and carbon dioxide slugs large enough to avoid interference between the oil-LPG, LPG-carbon dioxide and carbon dioxide- water displacement zones. Under these conditions, essentially complete oil and LPG recovery was obtained. However, a substantial amount of carbon dioxide was left in the core at water breakthrough.

Thompson, J.L.

1966-01-01T23:59:59.000Z

14

Industrial cooperation in the field of LPG  

SciTech Connect

The years to come should confirm the availability of LPG worldwide and enable future users in developing countries to satisfy energy requirements which today are only partly covered, if at all. This paper is designed to point the benefits that these new LPG markets could derive from active cooperation with experienced companies operating in mature LPG markets.

Stefano, M.; Trollux, J.; Dune, J.J.

1988-01-01T23:59:59.000Z

15

ESH100.2.OTH.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 2 Procedure Title Relocated - Perform Hot Work Safely Status Relocated Applicability, Exceptions, and Consequences For large populations of the work force, use this standard language: This corporate procedure applies to all Sandia National Laboratories (SNL) organizations, all management elements, all SNL sites, and all Members of the Workforce. If the above statement is not applicable to any particular groups, identify each excluded group here (e.g.,"Students are excluded from this procedure."). For small populations or subsets of populations, complete the follow standard phrase: This corporate procedure applies to all... (e.g., managers, students, radiation workers) Next, use the following standard language for exceptions and consequences: Exceptions to, or deviations from this procedure shall be approved through

16

Utilization of LPG for vehicles in Japan  

SciTech Connect

LPG demand for vehicles amounts to 1.8 MM tons annually, equivalent to about 11% of the total LPG consumption in Japan. The feature which dominates the demand of LPG as a vehicle fuel in Japan is the high penetration of LPG powered vehicles into taxi fleets. This has been made possible following the rationalization in the taxi business in the early 1960s. Today, three quarters of LPG vehicles, numbering some 235,000 while representing only about 1% of the total number of vehicles, account for nearly 93% of all taxicabs.

Kusakabe, M.; Makino, M.; Tokunoh, M.

1988-01-01T23:59:59.000Z

17

GAO report sabotages LPG industry  

SciTech Connect

A massive report by the U.S. General Accounting Office (GAO) on the liquefied energy gases (LEG), which include LPG and LNG, covers the possible hazards and recommends that facilities either be located in rural areas or, if in urban areas, be operated according to nuclear plant standards. One section concerns the ability of storage tanks to withstand earthquakes, floods, winds, and tornadoes. Another section treats transportation recommendations to eliminate as far as possible all opportunities for injury or destruction due to tank car or tank truck accidents. A discussion of the GAO report, only a portion of which has been released, sees the far-ranging recommendations as a threat to the LPG industry; notes that a great deal of information pertinent to the industry is presented in pointing out the problems, but finds that the GAO seems to have encountered considerable difficulty in finding practical solutions to the problems, e.g., in finding suitable sites for LPG terminals so that all such terminals can be in non-urban areas by 1980.

Roberts, B.

1978-03-01T23:59:59.000Z

18

Dehydrocyclodimerization, converting LPG to aromatics  

SciTech Connect

British Petroleum (BP) recognized the potential need for ways of exploiting feedstocks with low opportunity cost and commenced a research program at its Sunbury Research Center to discover and develop a catalyst for the conversion of LPG to a liquid product. The successful outcome of this research program is the Cyclar /SUP SM/ process, a joint development of UOP Process Division and British Petroleum. The Cyclar process offers a single-step conversion of LPG to an aromatic product which has a highvalue, is easily transported and useful both to fuel and petrochemical applications. The LPG producer can invest in a single unit, avoiding the need to identify and develop markets for multiple C/sub 3/ and C/sub 4/ products. This catalytic process, which employs UOP Continuous Catalyst Regeneration (CCR) technology, can also be applied to refinery light ends to produce a high-quality gasoline. Aromatic and hydrogen yields from propane and butane feeds surpass those obtained from catalytic reforming of Light Arabian naphtha. This paper describes the principles of the Cyclar process and illustrates yields and economics for several interesting applications.

Johnson, J.A.; Hilder, G.K.

1984-03-01T23:59:59.000Z

19

New LPG loss-control standards  

SciTech Connect

API'S (American Petroleum Institute) Committee on Liquified Hydrocarbon Gas and the Committee and Safety and Fire Protection have modified Standard 2510 and added a supplemental Standard 2510A, in response to bad LPG incidents. Requirements have been tightened, with a major objective to prevent LPG releases. Fire protection Standards for the design and operation of LPG facilities are specifically revised. Following important changes are specifically discussed: Versel design, site selection, spacing and impounding; foundations and supports; and piping requirements.

Blomquist, D.L. (Chevron Corp., San Francisco, CA (US))

1988-12-01T23:59:59.000Z

20

Impact of foreign LPG operations on domestic LPG markets  

SciTech Connect

During 1978 the federal government passed legislation allowing a major increase in natural gas prices and offering hope that some portion of the supply will be allowed to reach free market levels. The mechanism for decontrol of crude oil was also put into effect. This favorable government action and higher world oil prices have led to a major resurgence in domestic exploration. In addition to the supply effects, there appears to have been a substantial demand response to the latest round of world oil price increases. The purpose of this paper is to discuss how these events have affected domestic LPG markets and pricing.

Jones, C.

1981-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

LPG dealers, manufacturers report diverse effects of recession and war  

SciTech Connect

The author presents a survey of LPG marketers. The effects of the Persian Gulf War and U.S. recession on the LPG industry are discussed.

Prowler, S.

1991-01-01T23:59:59.000Z

22

Algeria LPG pipeline is build by Bechtel  

SciTech Connect

The construction of the 313 mile long, 24 in. LPG pipeline from Hassi R'Mel to Arzew, Algeria is described. The pipeline was designed to deliver 6 million tons of LPG annually using one pumping station. Eventually an additional pumping station will be added to raise the system capacity to 9 million tons annually.

Horner, C.

1984-08-01T23:59:59.000Z

23

Venezuela. [LPG marketing and production  

SciTech Connect

Liquefied petroleum gas marketing and production from Venezuela are not very complicated or big in the business. There is moderate LPG production since the main production comes from oil. There is about 2.3 million bpd of oil production compared with less than 70,000 bpd of gas liquids. Of more than 95% of the associated gas produced with the oil, 50% is injected as a condensate recovery process. Up to now, the LPG plants have been producing only a trickle, most of it from gas before it was injected. In the future program for gas utilization, it is estimated that by 1980 about twice the liquid that is now being produced would be available for exportation to natural markets of the Gulf of Mexico and the east coast. The production of about 7 million tons until the year 2000 can be continued with good conservation and with the future potential area that has been discovered in the south part of the lake and offshore Venezuela.

Reyes, A.

1977-01-01T23:59:59.000Z

24

Africa gaining importance in world LPG trade  

Science Conference Proceedings (OSTI)

Major LPG projects planned or under way in Africa will increase the importance of that region`s presence in world LPG trade. Supplies will nearly double between 1995 and 2005, at which time they will remain steady for at least 10 years. At the same time that exports are leveling, however, increasing domestic demand for PG is likely to reduce export-market participation by Algeria, Nigeria, Egypt, and Libya. The growth of Africa`s participation in world LPG supply is reflected in comparisons for the next 15--20 years. Total world supply of LPG in 1995 was about 165 million metric tons (tonnes), of which Africans share was 7.8 million tonnes. By 2000, world supply will grow to slightly more than 200 million tonnes, with Africa`s share expected to increase to 13.2 million tonnes (6.6%). And by 2005, world LPG supply will reach nearly 230 million tonnes; Africa`s overall supply volumes by that year will be nearly 16.2 million tonnes (7%). World LPG supply for export in 1995 was on order of 44 million tonnes with Africa supply about 4 million tonnes (9%). By 2005, world export volumes of LPG will reach nearly 70 million tonnes; Africa`s share will have grown by nearly 10 million tonnes (14.3%).

Haun, R.R. [Purvin and Gertz Inc., Dallas, TX (United States); Otto, K.W.; Whitley, S.C. [Purvin and Gertz Inc., Houston, TX (United States)

1997-05-12T23:59:59.000Z

25

Emissions from ethanol and LPG fueled vehicles  

DOE Green Energy (OSTI)

This paper addresses the environmental concerns of using neat ethanol and liquified petroleum gas (LPG) as transportation fuels in the US Low-level blends of ethanol (10%) with gasoline have been used as fuels in the US for more than a decade, but neat ethanol (85% or more) has only been used extensively in Brazil. LPG, which consists mostly of propane, is already used extensively as a vehicle fuel in the US, but its use has been limited primarily to converted fleet vehicles. Increasing US interest in alternative fuels has raised the possibility of introducing neat ethanol vehicles into the market and expanding the number of LPG vehicles. Use of such vehicles and increased production and consumption of fuel ethanol and LPG will undoubtedly have environmental impacts. If the impacts are determined to be severe, they could act as barriers to the introduction of neat ethanol and LPG vehicles. Environmental concerns include exhaust and evaporative emissions and their impact on ozone formation and global warming, toxic emissions from fuel combustion and evaporation, and agricultural emissions from production of ethanol. The paper is not intended to be judgmental regarding the overall attractiveness of ethanol or LPG compared to other transportation fuels. The environmental concerns are reviewed and summarized, but the only conclusion reached is that there is no single concern that is likely to prevent the introduction of neat ethanol fueled vehicles or the increase in LPG fueled vehicles.

Pitstick, M.E.

1992-12-31T23:59:59.000Z

26

Emissions from ethanol and LPG fueled vehicles  

DOE Green Energy (OSTI)

This paper addresses the environmental concerns of using neat ethanol and liquified petroleum gas (LPG) as transportation fuels in the US Low-level blends of ethanol (10%) with gasoline have been used as fuels in the US for more than a decade, but neat ethanol (85% or more) has only been used extensively in Brazil. LPG, which consists mostly of propane, is already used extensively as a vehicle fuel in the US, but its use has been limited primarily to converted fleet vehicles. Increasing US interest in alternative fuels has raised the possibility of introducing neat ethanol vehicles into the market and expanding the number of LPG vehicles. Use of such vehicles and increased production and consumption of fuel ethanol and LPG will undoubtedly have environmental impacts. If the impacts are determined to be severe, they could act as barriers to the introduction of neat ethanol and LPG vehicles. Environmental concerns include exhaust and evaporative emissions and their impact on ozone formation and global warming, toxic emissions from fuel combustion and evaporation, and agricultural emissions from production of ethanol. The paper is not intended to be judgmental regarding the overall attractiveness of ethanol or LPG compared to other transportation fuels. The environmental concerns are reviewed and summarized, but the only conclusion reached is that there is no single concern that is likely to prevent the introduction of neat ethanol fueled vehicles or the increase in LPG fueled vehicles.

Pitstick, M.E.

1992-01-01T23:59:59.000Z

27

Overfilling of cavern blamed for LPG blasts  

Science Conference Proceedings (OSTI)

Three explosions and a fire Apr. 7 at an LPG salt dome storage cavern near Brenham, Tex., were triggered when the cavern was overfilled, the Texas Railroad Commission (TRC) has reported. This paper reports that a TRC investigation found that LPG escaped to the surface at the Brenham site through brine injection tubing after excessive fill from an LPG line forced the cavern's water level below the brine tubing's bottom. At the surface, LPG was released into a brine storage pit where it turned into a dense, explosive vapor. At 7:08 a.m., the vapor was ignited by an unknown source. The resulting blast killed three persons and injured 19 and brought operations at the site to a halt.

Not Available

1992-07-06T23:59:59.000Z

28

New method developed for LPG offshore loading  

SciTech Connect

An innovative concept for refrigerated LPG offshore loading has been developed by TOTAL and Enterprise D'Equipments Mecaniques at Hydrauliques. Known as CHAGAL, the system integrates with the catenary anchor leg mooring offshore loading system commonly used for crude oil. CHAGAL provides a suitable answer to short-term development schemes of LPG trade. It can be adapted for possible extrapolation to cryogenic temperatures of LNG and it opens a new way to the development of offshore liquefaction projects for which the offloading of production is still an unsolved key problem.

1985-10-01T23:59:59.000Z

29

Custody transfer measurements for LNG/LPG  

SciTech Connect

The buying, selling, and transportation of Liquefied Natural Gas (LNG) and Liquefied Petroleum Gas (LPG) requires the use of sophisticated measurement systems for accurate determination of the total quantity and energy content for custody transfer reporting and safe cargo handling of these cryogenic products. These systems must meet strict safety standards for operation in a hazardous environment and, at the same time, provide accurate, reliable information for the storage, transfer, and data reporting required for both operational and financial accounting purposes. A brief discussion of LNG and LPG characteristics and detailed description of these special measurement techniques are given in this presentation.

Williams, R.A.

1984-04-01T23:59:59.000Z

30

Future of LPG as a petrochemical feedstock  

SciTech Connect

An evaluation is made of probable LPG (primarily propane) supplies and demand factors through 1985. The analysis indicates that because of diminishing domestic supplies and the transportation economics for foreign supplies the petrochemical industry will be forced to convert to the use of naphtha or heavy crude components for ethylene production. (JSR)

Skillern, M.P.

1976-10-01T23:59:59.000Z

31

Product transfer service chosen over LPG flaring  

SciTech Connect

Seadrift Pipeline Corp. recently decommissioned its Ella Pipeline, an 108-mile, 8-in. line between the King Ranch and a Union Carbide plant at Seadrift, Texas. The pipeline company opted for the product transfer services of pipeline Dehydrators Inc. to evacuate the ethane-rich LPG mixture from the pipeline instead of flaring the LPG or displacing it with nitrogen at operating pressures into another pipeline. The product transfer system of Pipeline Dehydrators incorporates the use of highly specialized portable compressors, heat exchangers and interconnected piping. The product transfer process of evacuating a pipeline is an economically viable method that safely recovers a very high percentage of the product while maintaining product purity. Using positive-displacement compressors, PLD transferred the LPG from the idled 8-in. Ella line into an adjacent 12-in. ethane pipeline that remained in service at approximately 800 psig. Approximately 4.3 million lb of LPG (97% ethane, 2.7% methane and 0.3% propane) were transferred into the ethane pipeline, lowering the pressure on the Ella Pipeline from 800 psig to 65 psig.

Horn, J.; Powers, M.

1994-07-01T23:59:59.000Z

32

Fire safety of LPG in marine transportation  

SciTech Connect

This report contains an analytical examination of cargo spill and fire hazard potential associated with the marine handling of liquefied petroleum gas (LPG) as cargo. Principal emphasis was on cargo transfer operations for ships unloading at receiving terminals, and barges loading or unloading at a terminal. Major safety systems, including emergency shutdown systems, hazard detection systems, and fire extinguishment and control systems were included in the analysis. Spill probabilities were obtained from fault tree analyses utilizing composite LPG tank ship and barge designs. Failure rates for hardware in the analyses were generally taken from historical data on similar generic classes of hardware, there being very little historical data on the specific items involved. Potential consequences of cargo spills of various sizes are discussed and compared to actual LPG vapor cloud incidents. The usefulness of hazard mitigation systems (particularly dry chemical fire extinguishers and water spray systems) in controlling the hazards posed by LPG spills and spill fires is also discussed. The analysis estimates the probability of fatality for a terminal operator is about 10/sup -6/ to 10/sup -5/ per cargo transfer operation. The probability of fatality for the general public is substantially less.

Martinsen, W.E.; Johnson, D.W.; Welker, J.R.

1980-08-01T23:59:59.000Z

33

Use expander cycles for LPG recovery  

SciTech Connect

Expander-type cycles are competitive with other gas recovery processes even when applied to relatively rich gas feeds for a high recovery of only propane plus. These cycles are the most economical to use when (1) ''free pressure drop'' is available between feed and residue gas pressure; (2) product requires demethanization only; (3) feed is very lean and propane plus heavier components are required; (4) a small, unattended, prefabricated unit for LPG recovery is needed; (5) an offshore LPG facility is required to be built on a platform where space and weight allowance is at a premium; (6) a facility is initially built for propane recovery, but is planned for future conversion to ethane recovery; and (7) relatively low-pressure gas feeds (which are usually quite rich) must be processed for a high recovery of ethane. A flow chart for an oil absorption plant is presented.

Valdes, A.R.

1974-01-01T23:59:59.000Z

34

Risk analysis of an LPG facility  

SciTech Connect

This paper describes methods used to conduct a safety review of an existing LPG loading, processing, and storage facility. An engineering team conducted a Hazard and Operability study of the plant to identify potential problems. A Probabilistic Risk Assessment was also made on the facility where the probability and consequences of worst case accidents were estimated. Stone and Webster recently completed an analysis of an LPG terminal to determine if there were any engineering, design, or operating deficiencies which could jeopardize the operability of the facility or make operation hazardous. The facility includes a dock for off-loading refrigerated propane and butane, transfer piping from the dock to storage, a heating system, pressurized storage, dehydration, product transfer and loading.

Daley, H.F.; Chapman, P.D.L.

1986-01-01T23:59:59.000Z

35

Blast rips Texas LPG storage site  

SciTech Connect

This paper reports that Seminole Pipeline Co. at presstime last week had planned to reopen its 775 mile liquefied petroleum gas pipeline in South Texas by Apr. 12 after a huge explosion devastated the area around a Seminole LPG storage salt dome near Brenham, Tex., forcing the pipeline shutdown. A large fire was still burning at the storage site at presstime last week. The blast - shortly after 7 a.m. Apr. 7 - occurred at a pipeline connecting the main Seminole line with the storage facility and caused shock waves felt 130 miles away. A 5 year old boy who lived in a trailer near Seminole's LPG storage dome was killed, and 20 persons were injured.

1992-04-13T23:59:59.000Z

36

Monitoring system tested during LPG tanker unloading  

SciTech Connect

A specially developed computer-based hazardous-materials monitoring system has been successfully field tested. The test of the portable system occurred during the unloading of 45,000 metric tons of LPG from a 740-ft tanker at the petroleum dock of a plant along the Mississippi River. The function of this system is to detect, report, alarm, and record unacceptable concentrations of hazardous vapors during marine-transfer operations.

1990-05-14T23:59:59.000Z

37

The operation of LPG relief valves  

SciTech Connect

As stipulated by NFPA 58, all LPG storage containers must be equipped with one or more pressure relief devices. These devices are sized to prevent rupture of a normally charged container when exposed to fire. This paper describes in detail the functioning of the spring-loaded relief valve. The author discusses how the venting of LPGs can produce unacceptable risks and how training is a necessary part of controlling such a situation.

Stannard, J.H. Jr

1989-11-01T23:59:59.000Z

38

Risks of LNG and LPG. [Review  

SciTech Connect

Since the use of liquefied natural gas (LNG) and liquefied petroleum gases (LPG) as fuels is likely to increase and will certainly persist for some time to come, assessment of the safety of LNG/LPG systems will continue to draw attention and is quite likely to force continuing review of operating and design standards for LNG/LPG facilities. Scientific investigations to date appear to have identified the major hazards. Except for the dispersive behavior of vapor clouds - a not-insignificant factor in risk evaluation - the consequences of spills are well circumscribed by current analyses. The physically significant effects accompanying nonexplosive combustion of spilled material are fairly well documented; yet, potentially substantial uncertainties remain. Catastrophic spills of 10/sup 4/-10/sup 5/ m/sup 3/ on land or water are possible, given the current size of storage vessels. Almost all experimental spills have used less than 10 m/sup 3/ of liquid. There is thus some uncertainty regarding the accuracy and validity of extrapolation of current empirical information and physical models to spills of catastrophic size. The less-likely but still-possible explosive or fireball combustion modes are not well understood in respect to their inception. The troubling experience with such violent combustion of similar combustible vapors suggests that this possibility will need further definition. Extant LNG and LPG risk analyses illustrate the difficulties of substantiating the numerous event probabilities and the determination of all event sequences that can lead to hazardous consequences. Their disparate results show that significant improvements are needed. Most importantly, a detailed critique of past efforts and a determination of an exhaustive set of criteria for evaluating the adequacy of a risk analysis should precede any further attempts to improve on existing studies. 44 references, 1 table.

Fay, J.A.

1980-01-01T23:59:59.000Z

39

LPG Electrical, Inc | Open Energy Information  

Open Energy Info (EERE)

LPG Electrical, Inc LPG Electrical, Inc Jump to: navigation, search Name LPG Electrical, Inc Address 13833 Wellington Trace Rd. #4 Place Wellington, Florida Zip 33414 Sector Services Product underwater power generators Year founded 2009 Number of employees 1-10 Phone number 5615786611 Website [www.lpgelectrical.com www.lpgelectrical.com ] Coordinates 26.663684°, -80.267246° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":26.663684,"lon":-80.267246,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

40

Mounded LPG storage - Experience and developments  

SciTech Connect

Liquefied petroleum gas (LPG) is stored after production, and for distribution and use, in pressure vessels which vary in size from a few kilogrammes to many thousands of tons. The types of LPG under consideration are commercial butane, commercial propane, or mixtures of the two gases in varying proportions. Mounded storage systems are becoming popular as an alternative to the better-known traditional systems. The most widely used and therefore best-known of the traditional systems are the above-ground pressure-vessel designs. These more commonly comprise factory-made cylinders which are installed horizontally, being supported on saddles at each end of the vessel. When such vessels are installed in an LPG terminal, depot, or filling plant, they are required in multiple units to facilitate the storage of more than one grade of product and to enable regular maintenance and inspection to be carried out. Today's safety regulations require such installations to be divided into sub-groups of six tanks, with all the tanks located at a safe distance from one another, and from other facilities in the immediate area. These safety distances are being increased as a result of experience, which means terminals now require large areas of land.

Barber, D.

1988-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

U.S. LPG pipeline begins deliveries to Pemex terminal  

SciTech Connect

LPG deliveries began this spring to the new Mendez LPG receiving terminal near Juarez, State of Chihuahua, Mexico. Supplying the terminal is the 265-mile, 8-in. Rio Grande Pipeline that includes a reconditioned 217-mile, 8-in. former refined-products pipeline from near Odessa, Texas, and a new 48-mile, 8-in. line beginning in Hudspeth County and crossing the US-Mexico border near San Elizario, Texas. Capacity of the pipeline is 24,000 b/d. The LPG supplied to Mexico is a blend of approximately 85% propane and 15% butane. Before construction and operation of the pipeline, PGPB blended the propane-butane mix at a truck dock during loading. Demand for LPG in northern Mexico is strong. Less than 5% of the homes in Juarez have natural gas, making LPG the predominant energy source for cooking and heating in a city of more than 1 million. LPG also is widely used as a motor fuel.

Bodenhamer, K.C. [Mid-America Pipeline Co., Tulsa, OK (United States)

1997-08-11T23:59:59.000Z

42

Combination process for the conversion of heavy distillates to LPG  

SciTech Connect

Maximum conversion of heavy distillates to LPG is achieved through a combination process involving two-stage hydrocracking. 9 claims, no drawings.

Hilfman, L.

1976-06-15T23:59:59.000Z

43

LPG fuel supply system. [Patent for automotive  

SciTech Connect

A fuel supply system for an internal combustion engine operated on gaseous fuels, for example, liquid petroleum gas (Lpg). The system includes a housing having a chamber for vaporizing liquid gas, including means for heating the vaporizing chamber. Also included in the housing is a mixing chamber for mixing the vaporized gas with incoming air for delivery to the intake manifold of an internal combustion engine through a standard carburetor. The fuel supply system includes means for mounting the system on the carburetor, including means for supporting an air filter circumjacent the mixing chamber.

Pierson, W.V.

1982-09-07T23:59:59.000Z

44

Current and future USA-world seaborne imports at LPG  

SciTech Connect

An outline of the current and historical situation of the international LPG trade and comparison between the US and other countries covers methods of marine transportation, including fully refrigerated vessels, semirefrigerated vessels, pressure vessels, and LNG ships fitted for LPG; the temporary abundance of LPG; a comparison of the markets in Japan, Europe, South America, and the US to indicate the potential market in the future, e.g., the need in Japan for LPG as a basic fuel, main use in Europe as a feedstock and as domestic fuel, use as a basic fuel but mainly in the winter months inSouth America, and the volatile spot market in the US; and the conclusion that the capacity to produce LPG will keep pace with demand only as long as adequate prices are paid to offset production costs.

Bassa, G.

1980-01-01T23:59:59.000Z

45

Legal nature of LPG (liquefied petroleum gas) regulation  

SciTech Connect

The commercial exploitation of Liquefied Petroleum Gas (LPG) in New Zealand has occurred without a particular and comprehensive concern for any legal implications. The paper in Part I examines definitional questions, assesses in Part II the ability of courts and quasi-courts to evaluate risks associated with the product, examines in Part III the utility of common law remedies for injuries or associated with or arising from LPG, analyzes in Part IV the statutory regulation of LPG, concentrating particularly on the Dangerous Goods (Class 2 - Gases) Regulations 1980, discusses in Part V recent planning case-law concerning LPG development, and concludes that some reform is necessary to produce a more-coherent and precise regulatory regime that takes into account both the needs of developers and those affected by the development of LPG.

Liddell, G.

1986-08-01T23:59:59.000Z

46

End to deficit of LPG. [Argentina  

SciTech Connect

In the Buenos Aires province of Argentina, Gas de Estado is constructing the future heart of the petrochemical complex, Bahia Blanca. The complex contains 2 absorption-refrigeration plants, a gas compressing plant, equipment maintenance shops and an important operations base for the Argentine truck gas pipelines. This will be the largest LPG plant in Latin America. The General Cerri plant, under construction, is located in an area of 40,000 sq m with new installations to extract ethane and higher hydrocarbons. The design optimizes the extraction of hydrocarbons from the natural gas and recovers 76% of the ethane. Selection of the process resulted from an investigation that compared the system with processes that use water cooling and absorption with refrigerated oil.

Andrich, V.

1980-03-01T23:59:59.000Z

47

Emissions from ethanol- and LPG-fueled vehicles  

SciTech Connect

This paper addresses the environmental concerns of using neat ethanol and liquefied petroleum gas (LPG) as transportation fuels in the United States. Low-level blends of ethanol (10%) with gasoline have been used as fuels in the United States for more than a decade, but neat ethanol (85% or more) has only been used extensively in Brazil. LPG, which consists mostly of propane, is already used extensively as a vehicle fuel in the United States, but its use has been limited primarily to converted fleet vehicles. Increasing U.S. interest in alternative fuels has raised the possibility of introducing neat-ethanol vehicles into the market and expanding the number of LPG vehicles. Use of such vehicles, and increased production and consumption of fuel ethanol and LPG, will undoubtedly have environmental impacts. If the impacts are determined to be severe, they could act as barriers to the introduction of neat-ethanol and LPG vehicles. Environmental concerns include exhaust and evaporative emissions and their impact on ozone formation and global warming, toxic emissions from fuel combustion and evaporation, and agricultural impacts from production of ethanol. The paper is not intended to be judgmental regarding the overall attractiveness of ethanol or LPG as compared with other transportation fuels. The environmental concerns are reviewed and summarized, but only conclusion reached is that there is no single concern that is likely to prevent the introduction of neat-ethanol-fueled vehicles or the increase in LPG-fueled vehicles.

Pitstick, M.E.

1995-06-01T23:59:59.000Z

48

Charcoal versus LPG grilling: A carbon-footprint comparison  

SciTech Connect

Undoubtedly, grilling is popular. Britons fire up their barbeques some 60 million times a year, consuming many thousands of tonnes of fuel. In milder climates consumption is even higher, and in the developing world, charcoal continues to be an essential cooking fuel. So it is worth comparing the carbon footprints of the two major grill types, charcoal and LPG, and that was the purpose of the study this paper documents. Charcoal and LPG grill systems were defined, and their carbon footprints were calculated for a base case and for some plausible variations to that base case. In the base case, the charcoal grilling footprint of 998 kg CO{sub 2}e is almost three times as large as that for LPG grilling, 349 kg CO{sub 2}e. The relationship is robust under all plausible sensitivities. The overwhelming factors are that as a fuel, LPG is dramatically more efficient than charcoal in its production and considerably more efficient in cooking. Secondary factors are: use of firelighters, which LPG does not need; LPG's use of a heavier, more complicated grill; and LPG's use of cylinders that charcoal does not need.

Johnson, Eric, E-mail: ejohnson@ecosite.co.u [Atlantic Consulting, Obstgartenstrasse 14, 8136 Gattikon (Switzerland)

2009-11-15T23:59:59.000Z

49

LPG export growth will exceed demand by 2000  

SciTech Connect

LPG supplies for international trade will increase sharply through 2000 and begin to outstrip demand by 1997 or 1998. This outlook depends on several production projects proceeding as planned. Leading the way to increased volumes are projects in Algeria, Nigeria, and Australia, among others. Purvin and Gertz, Dallas, projected this trend earlier this year at an international LPG seminar near Houston. Representatives from LPG-supplying countries also presented information to support this view and subsequently supplied more specifics to OGJ in response to questions. This paper discusses this information. Trends in Africa, Australia, North America, and South America are forecast.

True, W.R.

1994-08-08T23:59:59.000Z

50

Letter to the editor/Shell treats LPG  

SciTech Connect

In response to an article on the MALAPROP process Shell International Petroleum Mij. B.V. notes that Shell's Adip process has gained a solid position world-wide in economically treating very large amounts of LPG for the removal of hydrogen sulfide and carbonyl sulfide. Most Shell refineries are equipped with the Adip process, which cumulatively treates approx. 7000 tons/day of LPG. Middle East LPG facilities designed for the Arabian American Oil Co. treat 30,000 tons/day, and an additional 16,000 will come on stream in Jan. 1983. The removal of carbonyl sulfide to a few parts-per-million is easy.

1979-10-01T23:59:59.000Z

51

LPG-recovery processes for baseload LNG plants examined  

SciTech Connect

With demand on the rise, LPG produced from a baseload LNG plant becomes more attractive as a revenue-earning product similar to LNG. Efficient use of gas expanders in baseload LNG plants for LPG production therefore becomes more important. Several process variations for LPG recovery in baseload LNG plants are reviewed here. Exergy analysis (based on the Second Law of Thermodynamics) is applied to three cases to compare energy efficiency resulting from integration with the main liquefaction process. The paper discusses extraction in a baseload plant, extraction requirements, process recovery parameters, extraction process variations, and exergy analysis.

Chiu, C.H. [Bechtel Corp., Houston, TX (United States)

1997-11-24T23:59:59.000Z

52

FCC LPG olefinicity and branching enhanced by octane catalysts  

SciTech Connect

Refiners are increasingly recognizing the downstream opportunities for fluid catalytic cracking LPG olefins for the production of methyl tertiary butyl ether (MTBE), ethyl tertiary butyl ether (ETBE, if the ethanol subsidy is extended to the production of ETBE), and as petrochemical feedstocks. Some of new gasoline FCC octane-enhancing catalysts can support those opportunities because their low non-framework alumina (low NFA) preserve both LPG olefinicity and promote branching of the LPG streams from the FCCU. The combined effect results in more isobutane for alkylate feed, more propylene in the propane/propylene stream, and more isobutene - which makes the addition of an MTBE unit very enticing.

Keyworth, D.A.; Reid, T.A.; Kreider, K.R.; Yatsu, C.A.

1989-05-29T23:59:59.000Z

53

Monitoring, safety systems for LNG and LPG operators  

Science Conference Proceedings (OSTI)

Operators in Korea and Australia have chosen monitoring and control systems in recent contracts for LNG and LPG storage. Korea Gas Corp. (Kogas) has hired Whessoe Varec, Calais, to provide monitoring systems for four LNG storage tanks being built at Kogas` Inchon terminal. For Elgas Ltd., Port Botany, Australia, Whessoe Varec has already shipped a safety valve-shutdown system to a new LPG cavern-storage facility under construction. The paper describes the systems, terminal monitoring, dynamic approach to tank management, and meeting the growing demand for LPG.

True, W.R.

1998-11-16T23:59:59.000Z

54

World lpg forecast and implications for the U. S. Merchant Marine, 1978-1990  

SciTech Connect

This study summarizes historical and current LPG trade and vessels operating worldwide. It also forecasts LPG trade required for the U.S. and other major markets through 1990. Using an economic model to assess the market for LPG ships, the study forecasts vessel requirements for U.S. LPG trade and prospects for building required vessels in the U.S.

1978-05-01T23:59:59.000Z

55

LNG-LPG marine transportation and terminal safety  

SciTech Connect

A discussion of the vapor cloud behavior study the US Coast Guard has been carrying out since 1973 to develop design and operational controls for LNG and LPG ships and port facilities covers a brief review of the research work in the third phase of this study and the safety measures proposed by the Coast Guard and other regulatory bodies for operating LNG and LPG ships and waterfront facilities.

Bonekemper, E.H.

1977-01-01T23:59:59.000Z

56

River resort owners find LPG a power behind their success  

SciTech Connect

This paper reports on a restaurant and resort which runs entirely on LPG. It has two generators converted to LPG that supply the power for the complex. Energy supplied from the propane is used in the kitchens, to drive the water pump and provide electricity for lighting and other power needs, and to heat the swimming pool. Far more importantly for the owners has been the fuel cost savings of at least 60%.

1991-01-01T23:59:59.000Z

57

Accurate LPG analysis begins with sampling procedures, equipment  

SciTech Connect

Proper equipment and procedures are essential for obtaining representative samples from an LPG stream. This paper discusses how sampling of light liquid hydrocarbons generally involves one of two methods: flow- proportional composite sampling by a mechanical device or physical transfer of hydrocarbon fluids from a flowing pipeline or other source into a suitable portable sample container. If sampling by proper techniques and equipment supports careful chromatographic analysis, full advantage of accurate mass measurement of LPG can be realized.

Wilkins, C.M. (Koch Pipelines, Inc., Medford, OK (US))

1990-11-05T23:59:59.000Z

58

World`s LPG supply picture will change by 2000  

SciTech Connect

Middle East LPG producers will continue to dominate world export markets in 1996. Led by Saudi Arabia, the Middle East will produce nearly 26 million metric tons of LPG in million metric tons of LPG in 1996, more than 54% of the world`s almost 48 million metric tons of export LPG. In 2000, however, with world exports of LPG expanding to 58.9 million metric tons, Middle East suppliers; share will have remained flat, making up 31.7 million metric tons, or 53.9%. Saudi Arabia`s contribution will exceed 15 million metric tons, reflecting essentially no growth since 1995. These and other patterns, from data compiled by Purvin and Gertz, Dallas, and published earlier this year, show other suppliers of LPG, especially African (Algeria/Nigeria), North Sea, and Latin American (Venezuela/Argentina), picking up larger shares in the last 5 years of this decade. This scenario assumes completion of several major supply projects that are either panned, under construction, or nearing start up in most of these areas. The paper discusses the global picture, the supply situation in the Middle East, Africa, the North Sea, and South America.

True, W.R.

1995-11-06T23:59:59.000Z

59

Rio Grande pipeline introduces LPG to Mexico  

SciTech Connect

Rio Grande Pipeline, a joint venture between Mid-America Pipeline Co., Amoco Pipeline Co. and Navajo Pipeline Co., has broken new ground in the energy industry as the first LPG pipeline to cross the US-Mexico border. Plans for the project were announced in November 1995 and first deliveries started three months ago on March 21, 1997. The 8-inch, 265-mile pipeline originates near Odessa, TX, where it receives an 85-15 propane-butane mix via a connection to Mid-America Pipeline. From Odessa, product moves west through the Texas desert and crosses the Rio Grande River about 15 miles south of El Paso near Clint, TX and extends 20 miles into Mexico. Capacity of the line is 24,000 bpd and it has been averaging about 22,000 bpd since line-fill. All in all, it sounded like a reasonably feasible, routine project. But perceptions can be deceiving, or at least misleading. In other words, the project can be summarized as follows: one river, two cultures and a world of difference. The official border crossing for pipeline construction took place on Dec. 2, 1996, with a directional drill under the Rio Grande River, but in actuality, the joint venture partners were continually bridging differences in language, laws, customs and norms with Pemex and contracted workers from Mexico.

NONE

1997-06-01T23:59:59.000Z

60

Alternative Fuels Data Center: Oregon Laws and Incentives for Propane (LPG)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Oregon Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Oregon Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Oregon Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Oregon Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Oregon Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Oregon Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Oregon Laws and Incentives for Propane (LPG)

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Alternative Fuels Data Center: Iowa Laws and Incentives for Propane (LPG)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Iowa Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Iowa Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Iowa Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Iowa Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Iowa Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Iowa Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Iowa Laws and Incentives for Propane (LPG) The list below contains summaries of all Iowa laws and incentives related

62

Alternative Fuels Data Center: Utah Laws and Incentives for Propane (LPG)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Utah Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Utah Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Utah Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Utah Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Utah Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Utah Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Utah Laws and Incentives for Propane (LPG) The list below contains summaries of all Utah laws and incentives related

63

Alternative Fuels Data Center: Texas Laws and Incentives for Propane (LPG)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Texas Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Texas Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Texas Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Texas Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Texas Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Texas Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Texas Laws and Incentives for Propane (LPG) The list below contains summaries of all Texas laws and incentives related

64

Alternative Fuels Data Center: Maine Laws and Incentives for Propane (LPG)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Maine Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Maine Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Maine Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Maine Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Maine Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Maine Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Maine Laws and Incentives for Propane (LPG) The list below contains summaries of all Maine laws and incentives related

65

Alternative Fuels Data Center: Hawaii Laws and Incentives for Propane (LPG)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Hawaii Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Hawaii Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Hawaii Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Hawaii Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Hawaii Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Hawaii Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Hawaii Laws and Incentives for Propane (LPG)

66

Alternative Fuels Data Center: Kansas Laws and Incentives for Propane (LPG)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Kansas Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Kansas Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Kansas Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Kansas Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Kansas Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Kansas Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Kansas Laws and Incentives for Propane (LPG)

67

Alternative Fuels Data Center: Nevada Laws and Incentives for Propane (LPG)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Nevada Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Nevada Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Nevada Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Nevada Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Nevada Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Nevada Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Nevada Laws and Incentives for Propane (LPG)

68

Alternative Fuels Data Center: Alaska Laws and Incentives for Propane (LPG)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Alaska Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Alaska Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Alaska Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Alaska Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Alaska Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Alaska Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Alaska Laws and Incentives for Propane (LPG)

69

Alternative Fuels Data Center: Idaho Laws and Incentives for Propane (LPG)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Idaho Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Idaho Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Idaho Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Idaho Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Idaho Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Idaho Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Idaho Laws and Incentives for Propane (LPG) The list below contains summaries of all Idaho laws and incentives related

70

Alternative Fuels Data Center: Ohio Laws and Incentives for Propane (LPG)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Ohio Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Ohio Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Ohio Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Ohio Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Ohio Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Ohio Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Ohio Laws and Incentives for Propane (LPG) The list below contains summaries of all Ohio laws and incentives related

71

Indonesia's Arun LPG plant production is unique in Far East markets  

Science Conference Proceedings (OSTI)

Entry of the Arun (Indonesia) LNG plant into the LPG Far East markets is significant because its supplies for those markets are not tied to gas being extracted in association with crude oil. Arun LPG products are extracted from gas that is processed into and marketed as LNG. This article on the Arun LNG plant analyzes its LPG process and the significance of the LPG project on the plant's markets. Particular attention is paid to: 1.) LPG recovery; 2.) LPG fractionation; and 3.) Far East trade.

Naklie, M.M.; Penick, D.P.; Denton, L.A.; Kartiyoso, I.

1987-08-03T23:59:59.000Z

72

The importance of FCC catalyst selection on LPG profitability  

SciTech Connect

Recently the value of LPG in chemical operations downstream of the FCC unit has increased. Such downstream operations utilize propylene not only in alkylate, but also in rapid growth petrochemical applications such as for a raw material in the manufacture of polypropylene and propylene oxide. Isobutane and the butenes (particularly butene-2 in sulfuric acid catalyzed alkylation units) are prized for alkylate feed. The profit potential and incentives to use other LPG components such as isobutene to make MTBE is now increased because of legislative actions and increased octane performance demand; and because of the greater isobutene content in the LPG from the new FCC octane catalysts. A low non-framework alumina (NFA) zeolite studied made a more olefinic LPG with higher iso-to normal C4 ratio than the other zeolites. Pilot plant data has also shown the new low NFA zeolite gave not only outstanding motor octane (MON) performance, but produced an LPG with better propylene to propane ratio, more isobutene, more n-butenes and more C4 branching than other RE promoted zeolite catalysts. Commercial results have verified the improved performance and profitability for the new low-NFA type zeolite catalysts. Three commercial examples are described.

Keyworth, D.A.; Gilman, R.; Pearce, J.R. (AKZO Catalysts, 13000 Bay Park Road, Pasadena, TX (US))

1989-01-01T23:59:59.000Z

73

Demand for petrochem feedstock to buoy world LPG industry  

Science Conference Proceedings (OSTI)

This paper reports that use of liquefied petroleum gas as petrochemical feedstock will increase worldwide, providing major growth opportunities for LPG producers. World exports of liquefied petroleum gas will increase more slowly than production as producers choose to use LPG locally as chemical feedstock and export in value added forms such as polyethylene. So predicts Poten and Partners Inc., New York. Poten forecasts LPG production in exporting countries will jump to 95 million tons in 2010 from 45 million tons in 1990. However, local and regional demand will climb to 60 million tons/year from 23 million tons/year during the same period. So supplies available for export will rise to 35 million tons in 2010 from 22 million tons in 1990.

Not Available

1992-05-18T23:59:59.000Z

74

Experience with Bi-Fuel LPG Pickups in Texas  

DOE Green Energy (OSTI)

The State of Texas requires state agencies to purchase alternative fuel vehicles (AFVs). In 1996, Texas Department of Transportation (TxDOT) representatives added about 400 bi-fuel liquefied petroleum gas (LPG) pickup trucks to their fleet. The fleet managers were willing to share information about their fleets and the operation of these vehicles, so a study was launched to collect operations, maintenance, and cost data for selected LPG and gasoline vehicles (as controls) throughout 18 months of vehicle operation. This case study presents the results of that data collection and its subsequent analysis.

Whalen, P.

1999-05-12T23:59:59.000Z

75

Determination of usage patterns and emissions for propane/LPG in California. Final report  

SciTech Connect

The purpose of the study was to determine California usage patterns of Liquified Petroleum Gas (LPG), and to estimate propane emissions resulting from LPG transfer operations statewide, and by county and air basin. The study is the first attempt to quantify LPG transfer emissions for California. This was accomplished by analyzing data from a telephone survey of California businesses that use LPG, by extracting information from existing databases.

Sullivan, M.

1992-05-01T23:59:59.000Z

76

The Fuel Control System and Performance Optimization of a Spark-Ignition LPG Engine  

Science Conference Proceedings (OSTI)

This paper presents an approach to control air fuel ratio of a Liquefied Petroleum Gas (LPG) automotive engine. The optimization of compression ratio is also described in this paper. HC, CO & NOx emissions of LPG engines can be reduced after the application ... Keywords: control, LPG engine, air fuel ratio, optimization

Hongwei Cui

2009-04-01T23:59:59.000Z

77

Assessment of research and development (R and D) needs in LPG safety and environmental control  

Science Conference Proceedings (OSTI)

The report characterizes the LPG industry covering all operations from production to end use, reviews current knowledge of LPG release phenomenology, summarizes the status of current LPG release prevention and control methodology, and identifies any remaining safety and environmental problems and recommends R and D strategies that may mitigate these problems. (ACR)

DeSteese, J.G.

1982-05-01T23:59:59.000Z

78

Control and extinguishment of LPG fires. Final report  

SciTech Connect

Approximately 100 fire control and fire extinguishment tests were run on free-burning LPG pool fires from 25 ft/sup 2/ to 1600 ft/sup 2/ in area. The LPG was contained in concrete pits, and the pit floors were allowed to cool before the fires were ignited so that the burning rates were not influenced by boiloff from the warm floor. High expansion foam was used for fire control. The foam was applied from fixed generators located on the upwind side of the pit. Fires were controlled after foam application of less than a minute to about 10 minutes, depending on the application rate. Fires were extinguished with dry chemical agents applied through fixed piping systems with tankside nozzles and by manual application using hoselines and portable extinguishers. Fires could readily be extinguished in times ranging from a few seconds to about half a minute, depending on the application rate, system design, and ambient conditions. Additional tests were conducted in 1-ft/sup 2/ and 5-ft/sup 2/ pits to determine the boiloff rates for LPG spilled on concrete, a sand/soil mix, and polyurethane foam substrates. Burning rates for free-burning LPG pool fires from 1 ft/sup 2/ to 1600 ft/sup 2/ in area are also reported.

1980-06-01T23:59:59.000Z

79

Fire safety of LPG in marine transportation. Final report  

SciTech Connect

This report contains an analytical examination of cargo spill and fire hazard potential associated with the marine handling of liquefied petroleum gas (LPG) as cargo. Principal emphasis was on cargo transfer operations for ships unloading at receiving terminals, and barges loading or unloading at a terminal. Major safety systems, including emergency shutdown systems, hazard detection systems, and fire extinguishment and control systems were included in the analysis. Spill probabilities were obtained from fault tree analyses utilizing composite LPG tank ship and barge designs. Failure rates for hardware in the analyses were generally taken from historical data on similar generic classes of hardware, there being very little historical data on the specific items involved. Potential consequences of cargo spills of various sizes are discussed and compared to actual LPG vapor cloud incidents. The usefulness of hazard mitigation systems (particularly dry chemical fire extinguishers and water spray systems) in controlling the hazards posed by LPG spills and spill fires is also discussed. The analysis estimates the probability of fatality for a terminal operator is about 10/sup -6/ to 10/sup -5/ per cargo transfer operation. The probability of fatality for the general public is substantially less.

Martinsen, W.E.; Johnson, D.W.; Welker, J.R.

1980-06-01T23:59:59.000Z

80

U.S. LPG's Consumed at Refineries (Thousand Barrels)  

U.S. Energy Information Administration (EIA)

U.S. LPG's Consumed at Refineries (Thousand Barrels) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5 Year-6 Year-7 Year-8 Year-9; 1980's: 8,966: 8,021: 9,466: 11,962 ...

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Control and extinguishment of LPG fires. Final report  

SciTech Connect

Approximately 100 fire control and fire extinguishment tests were run on free-burning liquefied petroleum gases (LPG) pool fires from 25 ft/sup 2/ to 1600 ft/sup 2/ in area. The LPG was contained in concrete pits, and the pit floors were allowed to cool before the fires were ignited so that the burning rates were not influenced by boiloff from the warm floor. High expansion foam was used for fire control. The foam was applied from fixed generators located on the upwind side of the pit. Fires were controlled after foam application of less than a minute to about 10 minutes, depending on the application rate. Fires were extinguished with dry chemical agents applied through fixed piping systems with tankside nozzles and by manual application using hoselines and portable extinguishers. Fires could readily be extinguished in times ranging from a few seconds to about half a minute, depending on the application rate, system design, and ambient conditions. Additional tests were conducted in 1-ft/sup 2/ and 5-ft/sup 2/ pits to determine the boiloff rates for LPG spilled on concrete, a sand/soil mix, and polyurethane foam substrates. Burning rates for free-burning LPG pool fires from 1 ft/sup 2/ to 1600 ft/sup 2/ in area are also reported.

Johnson, D.W.; Martinsen, W.E.; Cavin, W.D.; Chilton, P.D.; Lawson, H.P.; Welker, J.R.

1980-08-01T23:59:59.000Z

82

Numerical Simulations of Leakage from Underground LPG Storage Caverns  

SciTech Connect

To secure a stable supply of petroleum gas, underground storage caverns for liquified petroleum gas (LPG) are commonly used in many countries worldwide. Storing LPG in underground caverns requires that the surrounding rock mass remain saturated with groundwater and that the water pressure be higher than the liquid pressure inside the cavern. In previous studies, gas containment criteria for underground gas storage based on hydraulic gradient and pressure have been discussed, but these studies do not consider the physicochemical characteristics and behavior of LPG such as vaporization and dissolution in groundwater. Therefore, while these studies are very useful for designing storage caverns, they do not provide better understanding of the either the environmental effects of gas contamination or the behavior of vaporized LPG. In this study, we have performed three-phase fluid flow simulations of gas leakage from underground LPG storage caverns, using the multiphase multicomponent nonisothermal simulator TMVOC (Pruess and Battistelli, 2002), which is capable of solving the three-phase nonisothermal flow of water, gas, and a multicomponent mixture of volatile organic chemicals (VOCs) in multidimensional heterogeneous porous media. A two-dimensional cross-sectional model resembling an actual underground LPG facility in Japan was developed, and gas leakage phenomena were simulated for three different permeability models: (1) a homogeneous model, (2) a single-fault model, and (3) a heterogeneous model. In addition, the behavior of stored LPG was studied for the special case of a water curtain suddenly losing its function because of operational problems, or because of long-term effects such as clogging of boreholes. The results of the study indicate the following: (1) The water curtain system is a very powerful means for preventing gas leakage from underground storage facilities. By operating with appropriate pressure and layout, gas containment can be ensured. (2) However , in highly heterogeneous media such as fractured rock and fault zones, local flow paths within which the gas containment criterion is not satisfied could be formed. To eliminate such zones, treatments such as pre/post grouting or an additional installment of water-curtain boreholes are essential. (3) Along highly conductive features such as faults, even partially saturated zones possess certain effects that can retard or prevent gas leakage, while a fully unsaturated fault connected to the storage cavern can quickly cause a gas blowout. This possibility strongly suggests that ensuring water saturation of the rock surrounding the cavern is a very important requirement. (4) Even if an accident should suddenly impair the water curtain, the gas plume does not quickly penetrate the ground surface. In these simulations, the plume takes several months to reach the ground surface.

Yamamoto, Hajime; Pruess, Karsten

2004-09-01T23:59:59.000Z

83

Carbon footprints of heating oil and LPG heating systems  

SciTech Connect

For European homes without access to the natural gas grid, the main fuels-of-choice for heating are heating oil and LPG. How do the carbon footprints of these compare? Existing literature does not clearly answer this, so the current study was undertaken to fill this gap. Footprints were estimated in seven countries that are representative of the EU and constitute two-thirds of the EU-27 population: Belgium, France, Germany, Ireland, Italy, Poland and the UK. Novelties of the assessment were: systems were defined using the EcoBoiler model; well-to-tank data were updated according to most-recent research; and combustion emission factors were used that were derived from a survey conducted for this study. The key finding is that new residential heating systems fuelled by LPG are 20% lower carbon and 15% lower overall-environmental-impact than those fuelled by heating oil. An unexpected finding was that an LPG system's environmental impact is about the same as that of a bio heating oil system fuelled by 100% rapeseed methyl ester, Europe's predominant biofuel. Moreover, a 20/80 blend (by energy content) with conventional heating oil, a bio-heating-oil system generates a footprint about 15% higher than an LPG system's. The final finding is that fuel switching can pay off in carbon terms. If a new LPG heating system replaces an ageing oil-fired one for the final five years of its service life, the carbon footprint of the system's final five years is reduced by more than 50%.

Johnson, Eric P., E-mail: ejohnson@ecosite.co.uk

2012-07-15T23:59:59.000Z

84

Upgrading Fischer-Tropsch LPG (liquefied petroleum gas) with the Cyclar process  

SciTech Connect

The use of the UOP/BP Cyclar{reg sign} process for upgrading Fischer-Tropsch (F-T) liquefied petroleum gas (LPG) was studied at UOP{reg sign}. The Cyclar process converts LPG into aromatics. The LPG derived from F-T is highly olefinic. Two routes for upgrading F-T LPG were investigated. In one route, olefinic LPG was fed directly to a Cyclar unit (Direct Cyclar). The alternative flow scheme used the Huels CSP process to saturate LPG olefins upstream of the Cyclar unit (Indirect Cyclar). An 18-run pilot plant study verified that each route is technically feasible. An economic evaluation procedure was designed to choose between the Direct and Indirect Cyclar options for upgrading LPG. Four situations involving three different F-T reactor technologies were defined. The main distinction between the cases was the degree of olefinicity, which ranged between 32 and 84 wt % of the fresh feed. 8 refs., 80 figs., 44 tabs.

Gregor, J.H.; Gosling, C.D.; Fullerton, H.E.

1989-04-28T23:59:59.000Z

85

"Table A10. Total Consumption of LPG, Distillate Fuel Oil, and Residual Fuel"  

U.S. Energy Information Administration (EIA) Indexed Site

0. Total Consumption of LPG, Distillate Fuel Oil, and Residual Fuel" 0. Total Consumption of LPG, Distillate Fuel Oil, and Residual Fuel" " Oil for Selected Purposes by Census Region and Economic Characteristics of the" " Establishment, 1991" " (Estimates in Barrels per Day)" ,,,," Inputs for Heat",,," Primary Consumption" " "," Primary Consumption for all Purposes",,," Power, and Generation of Electricity",,," for Nonfuel Purposes",,,"RSE" ," ------------------------------------",,," ------------------------------------",,," -------------------------------",,,"Row" "Economic Characteristics(a)","LPG","Distillate(b)","Residual","LPG","Distillate(b)","Residual","LPG","Distillate(b)","Residual","Factors"

86

Atomic Force Microscopy Studies of Lipophosphoglycan (LPG) Molecules in Lipid Bilayers  

SciTech Connect

Lipophosphoglycan (LPG) is a lypopolysaccharide found on the surface of the parasite Leishmania donovani that is thought to play an essential role in the infection of humans with leishamniasis. LPG acts as an adhesion point for the parasite to the gut of the sand fly, whose bite is responsible for transmitting the disease. In addition, LPG acts to inhibit protein kinase C (PKC) in the human macrophage, possibly by structural changes in the membrane. The Ca{sup 2+} ion is believed to play a role in the infection cycle, acting both as a crosslinker between LPG molecules and by playing a part in modulating PKC activity. To gain insight into the structure of LPG within a supported lipid membrane and into the structural changes that occur due to Ca{sup 2+} ions, we have employed the atomic force microscope (AFM). We have observed that the LPG molecules inhibit bilayer fusion, resulting in bilayer islands on the mica surface. One experiment suggests that the LPG molecules are parallel to the mica surface and that the structure of the LPG changes upon addition of Ca{sup 2+}, with an increase in the height of the LPG molecules from the bilayer surface and an almost complete coverage of LPG on the bilayer island.

LAST, JULIE A.; HUBER, TINA; SASAKI, DARRYL Y.; SALVATORE, BRIAN; TURCO, SALVATORE J.

2003-03-01T23:59:59.000Z

87

Successful operation of a large LPG plant. [Kuwait  

SciTech Connect

The LPG plant located at Mina-Al Ahmadi, Kuwait, is the heart of Kuwait Oil Co.'s massive Gas Project to use the associated gas from Kuwait's oil production. Operation of this three-train plant has been very successful. A description is given of the three process trains consisting of four basic units: extraction, fractionation, product treating, and refrigeration. Initial problems relating to extraction, fractionation, product treating and, refrigeration are discussed. 1 ref.

Shtayieh, S.; Durr, C.A.; McMillan, J.C.; Collins, C.

1982-03-01T23:59:59.000Z

88

New construction era reflected in East Texas LPG pipeline  

SciTech Connect

Installation of 240 miles of 6, 10, and 12-in. LPG pipelines from Mont Belvieu to Tyler, Tex., has provided greater feedstock-supply flexibility to a petrochemical plant in Longview, Tex. The project, which took place over 18 months, included tie-ins with metering at four Mont Belvieu suppliers. The new 10 and 12-in. pipelines now transport propane while the new and existing parts of a 6-in. pipeline transport propylene.

Mittler, T.J. (Texas Eastman Co., Longview, TX (US))

1990-04-02T23:59:59.000Z

89

LPG land transportation and storage safety. Final report  

SciTech Connect

This report contains an analytical examination of fatal accidents involving liquefied petroleum gas (LPG) releases during transportation and/or transportation related storage. Principal emphasis was on accidents during the nine-year period 1971 through 1979. Fatalities to members of the general public (i.e., those at the scene of the accident through coincidence or curiosity) were of special interest. Transportation accidents involving railroad tank cars, trucks, and pipelines were examined as were accidents at storage facilities, including loading and unloading at such facilities. The main sources of the necessary historical accident data were the accident reports submitted to the Department of Transportation by LPG carriers, National Transportation Safety Board accident reports, articles in the National Fire Protection Association journals, other literature, and personal interviews with firemen, company personnel, and others with knowledge of certain accidents. The data indicate that, on the average, releases of LPG during transportation and intermediate storage cause approximately six fatalities per year to members of the general public. The individual risk is about 1 death per 37,000,000 persons; about the same as the risk of a person on the ground being killed by an airplane crash, and much less than the risk of death by lightning, tornadoes, or dam failures.

Martinsen, W.E.; Cavin, W.D.

1981-09-01T23:59:59.000Z

90

LPG land transportation and storage safety. Final report  

SciTech Connect

This report contains an analytical examination of fatal accidents involving liquefied petroleum gas (LPG) releases during transportation and/or transportation related storage. Principal emphasis was on accidents during the nine-year period 1971 to 1979. Fatalities to members of the general public (i.e., those at the scene of the accident through coincidence or curiosity) were of special interest. Transportation accidents involving railroad tank cars, trucks, and pipelines were examined as were accidents at storage facilities, including loading and unloading at such facilities. The main sources of the necessary historical accident data were the accident reports submitted to the Department of Transportation by LPG carriers, National Transportation Safety Board accident reports, articles in the National Fire Protection Association journals, other literature, and personal interviews with firemen, company personnel, and others with knowledge of certain accidents. The data indicate that, on the average, releases of LPG during transportation and intermediate storage cause approximately six fatalities per year to members of the general public. The individual risk is about 1 death per 37,000,000 persons; about the same as the risk of a person on the ground being killed by an airplane crash, and much less than the risk of death by lightning, tornadoes, or dam failures.

1981-09-01T23:59:59.000Z

91

Far East LPG sales will grow faster than in West  

SciTech Connect

LPG sales through 2010 in regions east of the Suez Canal (East of Suez) will grow at more than twice those in regions west of the canal. East-of-Suez sales will grow at more than 4.0%/year, compared to slightly less than 2.0%/year growth in sales West of Suez. East-of-Suez sales will reach 92 million tons/year (tpy) by 2010, accounting for 39% of the worldwide total. This share was 31% in1995 and only 27% in 1990. LPG sales worldwide will reach 192 million tons in 2000 and 243 million tpy by 2010. In 1995, they were 163 million tons. These are some of the major conclusions of a recent study by Frank R. Spadine, Christine Kozar, and Rudy Clark of New York City-based consultant Poten and Partners Inc. Details of the study are in the fall report ``World Trade in LPG 1990--2010``. This paper discusses demand segments, seaborne balance, Western sources, largest trading region, North American supplies, and other supplies.

1996-12-30T23:59:59.000Z

92

Table A58. Capability to Switch from LPG to Alternative Energy Sources by  

U.S. Energy Information Administration (EIA) Indexed Site

8. Capability to Switch from LPG to Alternative Energy Sources by" 8. Capability to Switch from LPG to Alternative Energy Sources by" " Industry Group, Selected Industries, and Selected Characteristics, 1991" " (Estimates in Thousand Barrels)" ,," LPG",,," Alternative Types of Energy(b)" ,,"-","-","-------------","-","-","-","-","-","-","-","RSE" ,,"Total"," ","Not","Electricity",,,,,,,"Row" ,,"Consumed(b)","Switchable","Switchable","Receipts(d)","Gas","Fuel Oil","Fuel Oil","Coal","and Breeze","Other(e)","Factors"

93

Additional Development of a Dedicated Liquefied Petroleum Gas (LPG) Ultra Low Emissions Vehicle (ULEV)  

DOE Green Energy (OSTI)

This report describes the last in a series of three projects designed to develop a commercially competitive LPG light-duty passenger car that meets California ULEV standards and corporate average fuel economy (CAFE) energy efficiency guidelines for such a vehicle. In this project, IMPCO upgraded the vehicle's LPG vapor fuel injection system and performed emissions testing. The vehicle met the 1998 ULEV standards successfully, demonstrating the feasibility of meeting ULEV standards with a dedicated LPG vehicle.

IMPCO Technologies

1998-10-28T23:59:59.000Z

94

Additional Development of a Dedicated Liquefied Petroleum Gas (LPG) Ultra Low Emissions Vehicle (ULEV)  

SciTech Connect

This report describes the last in a series of three projects designed to develop a commercially competitive LPG light-duty passenger car that meets California ULEV standards and corporate average fuel economy (CAFE) energy efficiency guidelines for such a vehicle. In this project, IMPCO upgraded the vehicle's LPG vapor fuel injection system and performed emissions testing. The vehicle met the 1998 ULEV standards successfully, demonstrating the feasibility of meeting ULEV standards with a dedicated LPG vehicle.

IMPCO Technologies

1998-10-28T23:59:59.000Z

95

Asia, North America lead way in growth of NGL, LPG trade  

SciTech Connect

Recent analyses of world NGL trade indicate that important changes in LPG supply and demand are under way in Asia and North America. LPG markets in the 1990s reflect a rapidly shifting balance between East-of-Suez and West-of-Suez markets. This shift has increased concern about availability of future LPG supplies for Asia. The paper discusses world developments, East versus West of Suez, end uses and supplies in Asia, Canadian ethane, propane, butane, and natural gasoline, Mexican ethane, LPG, and natural gasoline, US ethane, propane, butanes, and iso-C{sub 4} and C{sub 5}.

Otto, K.; Gist, R.; Whitley, C. [Purvin and Gertz Inc., Houston, TX (United States); Haun, R. [Purvin and Gertz Inc., Dallas, TX (United States)

1998-01-12T23:59:59.000Z

96

Fuel switching from wood to LPG can benefit the environment  

SciTech Connect

The Himalaya in India is one of the world's biodiversity hotspots. Various scientific studies have reported and proven that many factors are responsible for the tremendous decline of the Himalayan forests. Extraction of wood biomass from the forests for fuel is one of the factors, as rural households rely entirely on this for their domestic energy. Efforts continue for both conservation and development of the Himalayan forests and landscape. It has been reported that people are still looking for more viable solutions that could help them to improve their lifestyle as well as facilitate ecosystem conservation and preservation of existing biodiversity. In this direction, we have documented the potential of the introduction of liquefied petroleum gas (LPG), which is one of the solutions that have been offered to the local people as a substitute for woodfuel to help meet their domestic energy demand. The results of the current study found dramatic change in per capita woodfuel consumption in the last two decades in the villages where people are using LPG. The outcome showed that woodfuel consumption had been about 475 kg per capita per year in the region, but after introduction of LPG, this was reduced to 285 kg per capita per year in 1990-1995, and was further reduced to 46 kg per capita per year in 2000-2005. Besides improving the living conditions of the local people, this transformation has had great environmental consequences. Empirical evidence shows that this new paradigm shift is having positive external effects on the surrounding forests. Consequently, we have observed a high density of tree saplings and seedlings in adjacent forests, which serves as an assessment indicator of forest health. With the help of the current study, we propose that when thinking about a top-down approach to conservation, better solutions, which are often ignored, should be offered to local people.

Nautiyal, Sunil [Leibniz-Centre for Agricultural Landscape Research (ZALF), Institute of Socioeconomics, Eberswalder Str. 84, 15374 Muencheberg (Germany)], E-mail: sunil.nautiyal@zalf.de; Kaechele, Harald [Leibniz-Centre for Agricultural Landscape Research (ZALF), Institute of Socioeconomics, Eberswalder Str. 84, 15374 Muencheberg (Germany)

2008-11-15T23:59:59.000Z

97

Cause not found for Texas LPG site blast  

SciTech Connect

This paper reports that National Transportation Safety Board investigators completed the first phase of tests at Seminole Pipeline Co.'s liquid petroleum gas storage dome near Brenham, Tex., without finding the cause of an explosion there Apr. 7. But in a week of investigation, NTSB determined that a release of brine and product occurred at the 350,000 bbl LPG storage dome, about 45 miles northwest of Houston, just before the blast. The explosion sent shock waves felt as far as 130 miles away. Three persons have died from injuries suffered in the accident. Another 18 were injured.

1992-04-20T23:59:59.000Z

98

System and method for converting wellhead gas to liquefied petroleum gases (LPG)  

SciTech Connect

A method of converting natural wellhead gas to liquefied petroleum gases (LPG) may comprise the steps of: separating natural gas from petroleum fluids exiting a wellhead; compressing the natural gas; refrigerating the natural gas, liquefying at least a portion thereof; separating LPG from gas vapors of the refrigerated natural gas; storing the separated LPG in a storage tank with a vapor space therein; and recirculating a portion of the LPG vapors in the storage tank with the natural gas exiting the wellhead to enhance recovery of LPG. A system for performing the method may comprise: a two-stage gas compressor connected to the wellhead; a refrigeration unit downstream of the gas compressor for refrigerating the compressed gases therefrom; at least one product separator downstream of the refrigerator unit for receiving refrigerated and compressed gases discharged from the refrigerator unit and separating LPG therein from gases remaining in vapor form; and a storage tank for receiving and storing the separated LPG therein, the storage tank having a vapor space therein connected upstream of the gas compressor through a pressure regulator allowing recirculation of some LPG vapors with the natural gases through said system.

May, R.L.; Sinclair, B.W.

1984-07-31T23:59:59.000Z

99

What's ahead for LNG/LPG  

SciTech Connect

The growth of the LNG, LPG, and pipeline bulk distribution gas markets depends on the availability of capital, including an estimated $60 billion by the end of the 1980's for LNG alone to support a network of projects moving approx. 15 billion cu ft/day throughout the world, which will require long-term (averaging over 20 yr) index-linked contracts for the gas. According to the American Gas Association, import of LNG as opposed to an equivalent amount of energy from crude oil would offer the U.S. several advantages, including significant capital investment for LNG facilities in the U.S. and a larger proportion of imports moving in U.S. owned and constructed tankers. The growth of international LNG trade will also depend on the extent to which gas processing and transportation costs can be decreased by increasing LNG tanker size, on the demand for natural gas, and on U.S. gas pricing policy. Plausible trends in LNG/LPG trade through the 1980's, and the requirement for high gas prices as an incentive for gas resource development in several countries, including the U.S., are discussed.

Remington, P.; Fraser, M.

1979-09-01T23:59:59.000Z

100

New pemex agency, smog checks greet Mexican LPG vehicle users  

Science Conference Proceedings (OSTI)

This paper reports that the relaxation of prohibitions on the use of propane as a motor fuel has spurred sizeable business activity in carburetion and higher demand for LPG throughout Mexico and particularly in Mexico City. However, a number of unforeseen problems have developed that required tough, immediate solutions. After the alternative fuels project began at city hall in Mexico City, publicity spread nationwide, reportedly spurring conversion activity in many other cities. That led to additional demand for fuel of a magnitude that few people had anticipated. In order to assume control of the situation, the national oil company, Pemex, established an official LPG Motor Fuel Department on June 1. Operating in conjunction with the Ministry of Industry, the new department has been busy registering every major propane-powered fleet in the country. Most important, the rate of conversion work must now be pegged to the availability of fuel. It is believed that conversion activity has become more evenly paced since the new Pemex agency took over.over.

Not Available

1992-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Alternative fuel information: Facts about CNG and LPG conversion  

DOE Green Energy (OSTI)

As new environmental and energy related laws begin to take effect, increasing numbers of alternative fuel vehicles (AFVs) will be required in federal, state, municipal, and private fleets across the country. The National Energy Policy Act of 1992 and the Clean Air Act Amendments of 1990, along with several new state and local laws, will require fleet managers to either purchase original equipment manufacturer (OEM) vehicles, which are produced by automakers, or convert existing vehicles to run on alternative fuels. Because there is a limited availability and selection of OEM vehicles, conversions are seen as a transition to the time when automakers will produce more AFVs for public sale. A converted vehicle is any vehicle that originally was designed to operate on gasoline, and has been altered to run on an alternative fuel such as compressed natural gas (CNG) or propane (liquefied petroleum gas -- LPG), the two most common types of fuel conversions. In the United States, more than 25,000 vehicles already have been converted to COG, and 300,000 have been converted to LPG.

O`Connor, K.

1994-06-01T23:59:59.000Z

102

Latest techniques and equipment for the conversion of motor vehicles to LPG/petroleum use  

SciTech Connect

Liquified petroleum gases (LPG) has been used for transportation in Europe, the United States, Japan and to a much lesser extent in Australia for many years. In most cases, the vehicles have been powered by engines designed for petrol operation and subsequently converted to use LPG. The application of LPG as an automotive fuel in different countries depends heavily on the availability of the fuel and the tax policy of the government. The demand for dual fuel equipment is increasing. Some of the problems facing Australia to convert vehicles to LPG use emphasize the institutional and hardware obstacles. Before LPG can be considered to be a safe, viable alternative fuel to petrol, improvements will have to be made in safety standards, in reduced exhaust emissions, in increased fuel efficiency, and in the involvement of car manufacturers. (SAC)

Armstrong, R.

1980-01-01T23:59:59.000Z

103

Fire protection considerations for the design and operation of liquefied petroleum gas (LPG) storage facilities  

SciTech Connect

This standard addresses the design, operation, and maintenance of LPG storage facilities from the standpoint of prevention and control of releases, fire-protection design, and fire-control measures, as well as the history of LPG storage facility failure, facility design philosophy, operating and maintenance procedures, and various fire-protection and firefighting approaches and presentations. The storage facilities covered are LPG installations (storage vessels and associated loading/unloading/transfer systems) at marine and pipeline terminals, natural gas processing plants, refineries, petrochemical plants, and tank farms.

1989-01-01T23:59:59.000Z

104

Table 4. LPG Consumption and Expeditures in U.S. Households by End ...  

U.S. Energy Information Administration (EIA)

Table 4. LPG Consumption and Expeditures in U.S. Households by End Uses and Census Region, 2001 RSE Column Factor: Total U.S. Census Region RSE Row

105

Method and apparatus for transfer of liquefied gas. [hydrogen, LPG, or LNG  

SciTech Connect

A method and apparatus for transferring a liquefied gas (hydrogen, LPG, or LNG) from a first container into a second container without removal of vapor from the second container is disclosed.

Gee, D.E.; Worboys, R.V.

1976-06-15T23:59:59.000Z

106

Century-Midas steps slowly into the RV (recreational vehicles) LPG conversion market  

SciTech Connect

Midas International will obtain LPG carburetion equipment from Century for installation in up to 20,000 RV. The market for gasoline-powered RV has been depressed since the surge in gasoline prices, and the installation of Century's equipment represents an attempt to attract customers by reducing RV operating costs. According to J. Kincaid (Midas Inst.), propane, besides being cheaper than gasoline, is also cheaper than diesel fuel, despite the better mileage obtained with diesel fuel, because the use of diesel fuel requires the installation of a diesel engine, which is far more expensive than installation of LPG carburetion. Although most of the LPG carburetion manufacturers, with a backlog of orders, did not evince interest in Midas' search for conversion equipment for RV, Century responded, at least partly because Midas also manufactures fleet delivery trucks, which represent a potentially much larger market for LPG conversion and use.

Kincaid, J.

1980-02-01T23:59:59.000Z

107

Evaluation of aftermarket LPG conversion kits in light-duty vehicle applications. Final report  

DOE Green Energy (OSTI)

SwRI was contracted by NREL to evaluate three LPG conversion kits on a Chevrolet Lumina. The objective of the project was to measure the Federal Test Procedure (FTP) emissions and fuel economy of these kits, and compare their performance to gasoline-fueled operation and to each other. Varying LPG fuel blends allowed a preliminary look at the potential for fuel system disturbance. The project required kit installation and adjustment according to manufacturer`s instructions. A limited amount of trouble diagnosis was also performed on the fuel systems. A simultaneous contract from the Texas Railroad Commission, in cooperation with NREL, provided funds for additional testing with market fuels (HD5 propane and industry average gasoline) and hydrocarbon (HC) emissions speciation to determine the ozone-forming potential of LPG HC emissions. This report documents the procurement, installation, and testing of these LPG conversion kits.

Bass, E.A. [Southwest Research Inst., San Antonio, TX (US)] [Southwest Research Inst., San Antonio, TX (US)

1993-06-01T23:59:59.000Z

108

Offshore refrigerated LPG loading/unloading terminal using a CALM buoy  

SciTech Connect

In existing Liquefied Petroleum Gases terminals, the transfer of liquefied gases to the tanker is performed via articulated loading arms or flexible hoses, working under quasistatic conditions. The tanker has to be firmly moored alongside a jetty or a process barge in a protected area (such as a harbour in most cases). This paper gives the main results of the development of an offshore refrigerated LPG (-48/sup 0/C) loading/unloading system, using a CALM buoy and LPG floating hoses working under dynamic conditions. The aim of this new concept is to replace the standard harbour structure for loading/unloading refrigerated LPG and to provide a considerable reduction in investments and a greater flexibility regarding the terminal location. The main components of that terminal have been designed so as to enable the loading of a 75 000 cubic meter LPG carrier in 15 hours. The results of static and dynamic low temperature tests on a LPG swivel joint for CALM buoy and LPG floating hoses show that such a SPM terminal is now a realistic solution.

Bonjour, E.L.; Simon, J.M.

1985-03-01T23:59:59.000Z

109

Getting performance without sacrificing economy or emissions control in a heavy-duty LPG engine  

SciTech Connect

A commercial 637 CID liquefied petroleum gas (LPG) engine was evaluated as a candidate powerplant for new bus purchases and/or as a replacement for obsolete LPG engines currently being used in metropolitan Chicago bus service. Limited route service experience with LPG conversion of a gasoline engine indicated both its potential and the need for its optimization in order to take advantage of the unique characteristics of LPG. The engine-dynamometer study, with emphasis on fuel system-ignition relationships, led to substantial improvement in fuel economy without depreciation of engine power. The 637 CID LPG engine fuel economy was increased from an average of 1.77 mpg for 1965 to 1971 to 2.60 mpg for the Dec. 1971 to April 1972 period in Chicago field tests. Cylinder head redesign permitted lean mixture operation that reduced exhaust emissions to levels calculated to conform to the 1973 Federal standards and the 1973-1974 California Air Resources Board requirements for heavy-duty engines. The exhaust emissions data obtained with the optimized 7.5:1 CR engine based on the California 13-mode cycle were 8.3 g/bhp/hr carbon monoxide and 9.9 g/bhp/hr hydrocarbons plus nitrogen dioxide.

Mengelkamp, R.A.; Linnard, R.E.

1973-01-01T23:59:59.000Z

110

Determination of combustion products from alternative fuels - part 1. LPG and CNG combustion products  

SciTech Connect

This paper describes efforts underway to identify volatile organic exhaust species generated by a light-duty vehicle operating over the Federal Test Procedure (FTP) on CNG and LPG, and to compare them to exhaust constituents generated from the same vehicle operating on a fuel blended to meet California Phase 2 specifications. The exhaust species from this vehicle were identified and quantified for fuel/air equivalence ratios of 0.8, 1.0, and 1.2, nominally, and were analyzed with and without the vehicle`s catalytic converter in place to determine the influence of the vehicle`s catalyst on species formation. Speciation data showed greater than 87 percent of all LPG and greater than 95 percent of all CNG hydrocarbon exhaust constituents to be composed of C{sub 1} to C{sub 3} compounds. In addition, toxic emissions from the combustion of CNG and LPG were as low as 10 percent of those generated by combustion of gasoline. A comparison of ozone forming potential of the three fuels was made based on the Maximum Incremental Reactivity scale used by the California Air Resources Board. Post-catalyst results from stoichiometric operation indicated that LPG and CNG produced 63 percent and 88 percent less potential ozone than reformulated gasoline, respectively. On average over all equivalence ratios, CNG and LPG exhaust constituents were approximately 65 percent less reactive than those from reformulated gasoline. 4 refs., 3 figs., 14 tabs.

Whitney, K.A.; Bailey, B.K.

1994-10-01T23:59:59.000Z

111

Cascaded'' pilot regulators help reduce LPG loss in hot weather  

SciTech Connect

Fina Oil and Chemical Co. and Fisher Controls International used engineering resourcefulness to overcome heat-induced product loss from LPG storage bullets at Fina's Port Arthur, Tex., refinery. Fina had installed Fisher's Easy Joe 399A-6365, a pilot-operated, back-pressure-type regulator, on its LPG storage facility in 1991 as part of a fuel products modernization project. The regulators helped control the accumulation of noncondensible vapors, which collect in the storage bullets above the LPG. But summer heat extremes and surges in the tanks and lines made it possible for the operating pressure to increase so that the safety relief valve was activated before the pilot regulator was able to stabilize the pressure. The installation of pilot-type regulators, in cascaded, or series, formation, reduced product venting through relief valves.

1994-08-08T23:59:59.000Z

112

System and method for converting wellhead gas to liquefied petroleum gases (LPG)  

SciTech Connect

A method of converting natural wellhead gas to liquefied petroleum gases (LPG) may comprise the steps of: separating natural gas from petroleum fluids exiting a well-head; compressing the natural gas; refrigerating the natural gas, liquefying at least a portion thereof; and separating LPG from gas vapors of the refrigerated natural gas. A system for performing the method may comprise: a two-stage gas compressor connected to the wellhead; a refrigeration unit downstream of the gas compressor for cooling the compressed gases therefrom; and a product separator downstream of the refrigeration unit for receiving cooled and compressed gases discharged from the refrigeration unit and separating LPG therein from gases remaining in vapor form.

May, R.L.; Snow, N.J. Jr.

1983-12-06T23:59:59.000Z

113

New and existing gas wells promise bountiful LPG output in Michigan  

SciTech Connect

Michigan remains the leading LP-gas producer in the Northeast quadrant of the U.S. This paper reports that boosted by a number of new natural gas wells and a couple of new gas processing plants, the state is firmly anchored in the butane/propane production business. Since 1981, more than 100 deep gas wells, most in excess of 8000 feet in depth, have been completed as indicated producers in the state. Many of these are yielding LPG-grade stock. So, combined with LPG-grade production from shallower geologic formations, the supply picture in this area looks promising for the rest of the country.

1991-01-01T23:59:59.000Z

114

Local government energy management: liquid petroleum gas (LPG) as a motor vehicle fuel  

SciTech Connect

The retrofit or conversion of automotive engines to operate on liquid petroleum gas (LPG) or propane fuel is one of many potentially cost-effective strategies for reducing a local government's annual fleet operating and maintenance costs. The cost effectiveness of an LPG conversion decision is highly dependent on the initial conversion cost, vehicle type, current and projected fuel costs, vehicle fuel economy (miles per gallon), and yearly average mileage. A series of plots have been developed which indicate simple paybacks for the conversion of several vehicle types (passenger car, small and standard pickups, and two and three ton trucks) over a wide range of fuel economies and annual usage patterns. A simple payback of less than three years can be achieved for vehicles with poor fuel economy and high annual use. The figures provided in this report may be used by fleet management personnel as a screening tool to identify those passenger cars, small or standard pickups, or light duty trucks which are candidates for LPG conversion. In addition to examining the benefits of an LPG conversion, local governments should also consider the competing energy management strategies of downsizing, and the acquisition of fuel efficient, diesel powered vehicles.

McCoy, G.A.; Kerstetter, J.

1983-10-01T23:59:59.000Z

115

Technical evaluation and assessment of CNG/LPG bi-fuel and flex-fuel vehicle viability  

DOE Green Energy (OSTI)

This report compares vehicles using compressed natural gas (CNG), liquefied petroleum gas (LPG), and combinations of the two in bi-fuel or flex-fuel configurations. Evidence shows that environmental and energy advantages can be gained by replacing two-fuel CNG/gasoline vehicles with two-fuel or flex-fuel systems to be economically competitive, it is necessary to develop a universal CNG/LPG pressure-regulator-injector and engine control module to switch from one tank to the other. For flex-fuel CNG/LPG designs, appropriate composition sensors, refueling pumps, fuel tanks, and vaporizers are necessary.

Sinor, J E [Sinor (J.E.) Consultants, Inc., Niwot, CO (United States)

1994-05-01T23:59:59.000Z

116

Gas processing/The boiling behavior of LPG and liquid ethane, ethylene, propane, and n-butane spilled on water  

SciTech Connect

Boiling-rate calorimeter studies showed that unlike liquid nitrogen, methane, and LNG, LPG (84.7% propane, 6.0% ethane, and 9.3% n-butane; 442/sup 0/C bp), or pure propane, when rapidly spilled on water, reacted violently, ejecting water and ice into the vapor space; but in 1-2 sec, a coherent ice layer was formed and further boiloff was quiet and well predicted by a simple one-dimensional, moving-boundary-value, heat transfer model with a growing ice shield. Increasing the content of ethane and butane in LPG to 20% and 10%, respectively, had almost no effect on the LPG boiling, indicating that boiling may be modeled by using pure propane. Ethane, ethylene, and n-butane behaved quite differently from LPG. In spills of pure liquid propane on solid ice, the boiloff rate was almost identical to that predicted by the moving-boundary model.

Reid, R.C.; Smith, K.A.

1978-04-01T23:59:59.000Z

117

Alvord (3,000-ft strawn) LPG flood - design and performance evaluation  

SciTech Connect

Mitchell Energy Corporation has implemented a LPG-dry gas miscible process in the Alvord (3000' Strawn) Unit in Wise County, Texas utilizing the DOE tertiary incentive program. The field had been waterflooded for 14 years and was producing near its economic limit at the time this project was started. This paper presents the results of the reservoir simulation study that was conducted to evaluate pattern configuration and operating alternatives so as to maximize LPG containment and oil recovery performance. Several recommendations resulting from this study were implemented for the project. Based on the model predictions, tertiary oil recovery is expected to be between 100,000 and 130,000 bbls, or about 7 percent of the oil originally in place in the Unit. 12 refs.

Frazier, G.D.; Todd, M.R.

1982-01-01T23:59:59.000Z

118

LIQUID PROPANE GAS (LPG) STORAGE AREA BOILING LIQUID EXPANDING VAPOR EXPLOSION (BLEVE) ANALYSIS  

SciTech Connect

The PHA and the FHAs for the SWOC MDSA (HNF-14741) identified multiple accident scenarios in which vehicles powered by flammable gases (e.g., propane), or combustible or flammable liquids (e.g., gasoline, LPG) are involved in accidents that result in an unconfined vapor cloud explosion (UVCE) or in a boiling liquid expanding vapor explosion (BLEVE), respectively. These accident scenarios are binned in the Bridge document as FIR-9 scenarios. They are postulated to occur in any of the MDSA facilities. The LPG storage area will be in the southeast corner of CWC that is relatively remote from store distaged MAR. The location is approximately 30 feet south of MO-289 and 250 feet east of 2401-W by CWC Gate 10 in a large staging area for unused pallets and equipment.

PACE, M.E.

2004-01-13T23:59:59.000Z

119

Converting LPG caverns to natural-gas storage permits fast response to market  

Science Conference Proceedings (OSTI)

Deregulation of Canada`s natural-gas industry in the late 1980s led to a very competitive North American natural-gas storage market. TransGas Ltd., Regina, Sask., began looking for method for developing cost-effective storage while at the same time responding to new market-development opportunities and incentives. Conversion of existing LPG-storage salt caverns to natural-gas storage is one method of providing new storage. To supply SaskEnergy Inc., the province`s local distribution company, and Saskatchewan customers, TransGas previously had developed solution-mined salt storage caverns from start to finish. Two Regina North case histories illustrate TransGas` experiences with conversion of LPG salt caverns to gas storage. This paper provides the testing procedures for the various caverns, cross-sectional diagrams of each cavern, and outlines for cavern conversion. It also lists storage capacities of these caverns.

Crossley, N.G. [TransGas Ltd., Regina, Saskatchewan (Canada)

1996-02-19T23:59:59.000Z

120

LPG buses in southern California leave the competition at the curb  

SciTech Connect

This paper reports that after the first year of a landmark experiment in which LPG has been competing against methanol and CNG in city buses, propane appears to be pulling out in front of the pack. According to Efren Medellin, superintendent of vehicle maintenance at the Orange County Transit Authority, two LPG buses had registered a total of 31,000 moles with relatively little, if any, downtime. The two methanol buses had run a total of 30,000 miles while the two CNG buses had traveled only 5000 miles. Furthermore the methanol and CNG buses have had their share of downtime for new parts and other problems. The propane-powered buses appear to be running consistently well without mechanical difficulties. The only problem that occurred was occasional backfiring. As a result, the electronic controls were replaced and no subsequent complaints were heard.

1992-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Conception and construction of an LPG tank using a composite membrane technology  

SciTech Connect

TECHNIGAZ and TOTAL C.F.P. have developed a new LPG storage technology derived from the membrane concept used for LNG storage and transportation. This technology called GMS uses a composite membrane as primary barrier. A 2 000 m/sup 3/ storage pilot unit, based on that concept, is under construction in TOTAL's refinery at DUNKIRK (France) since September 1983.

Fuvel, P.; Claude, J.

1985-03-01T23:59:59.000Z

122

Radiological health implications of lead-210 and polonium-210 accumulations in LPG refineries  

SciTech Connect

Radon-222, a naturally occurring radioactive noble gas, is often a contaminant in natural gas. During fractionation at processing plants, Radon tends to be concentrated in the Liquified Petroleum Gas (LPG) product stream. Radon-222 decays into a number of radioactive metallic daughters which can plate out on the interior surfaces of plant machinery. The hazards associated with gamma-emitting short-lived radon daughters have been investigated previously. The present work reports an analysis of the hazards associated with the long-lived daughters; Pb-210, Bi-210, and Po-210. These nuclides do not emit appreciable penetrating radiation, and hence do not represent a hazard as long as they remain on the inside surfaces of equipment. However, when equipment that has had prolonged exposure to an LPG stream is disassembled for repair or routine maintenance, opportunities for exposure to radioactive materials can occur. A series of measurements made on an impeller taken from a pump in an LPG facility is reported. Alpha spectroscopy revealed the presence of Po-210, and further measurements showed that the amount on the impeller surface was well above the exempt quantity. Breathing zone measurements made in the course of cleaning the impeller showed that an inhalation exposure equivalent to breathing Po-210 at the Maximum Permissible Concentration (MPC) for 60 hours could be delivered in less than half an hour. It was concluded that maintenance and repair work on LPG and derivitive product stream equipment must be carried out with the realization that a potential radiological health problem exists.

Summerlin, J. Jr.; Prichard, H.M.

1985-04-01T23:59:59.000Z

123

N/sub 2/-driven LPG achieves miscibitity at high temperatures  

SciTech Connect

Shows that miscibility can be achieved at very low pressures above the critical temperature of propane. One can calculate the critical pressure and temperature for a variety of fluids of practical interest in achieving miscibility between the miscible slug and driving gas when applying enhanced oil recovery programs. A study of the critical properties of normally available reservoir fluids indicates that one method of achieving miscibility at lower pressures, even at high reservoir temperatures, might be to use LPG slugs pushed by nitrogen. Table gives the oil recovery for different LPG slug sizes when operating at a reservoir pressure of 2,000 psig and a reservoir temperature of 250F. Diagram shows the approximate critical temperature loci for ternary systems made up of 3 components from the group nitrogen, methane, ethane, and propane. By finding the desired reservoir temperature and then estimating the critical pressure required, one may select compositions and operating pressures required to achieve critical slug-driving gas mixtures for use in enhanced oil recovery programs. When using CO/sub 2/ for miscibility, the miscibility pressure increases with temperature. Use of LPG slugs results in a substantial reduction in the pressure required for miscibility.

Carlisle, L.; Crawford, P.B.; Montes, M. Jr.; Reeves, S.

1982-11-01T23:59:59.000Z

124

Cities - Residents | Data.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Residents Cities Data Apps Challenges Policies Cities You are here Data.gov Communities Cities Residents Looking for cool ways to explore your city, services, and...

125

Pressurized release of liquefied fuel gases (LNG and LPG). Topical report, May 1993-February 1996  

SciTech Connect

This report is an important contribution to the behavior of pressurized liquefied gases when accidentally released into the atmosphere. LNG vehicle fueling stations and LPG storage facilities operate at elevated pressures. Accidental releases could result in rainout and the formation of an aerosol in the vapor cloud. These factors must be considered when estimating the extent of the hazard zone of the vapor cloud using a heavier-than-air gas dispersion model such as DEGADIS (or its Windows equivalent DEGATEC). The DOS program PREL has been incorporated in the Windows program LFGRISK.

Atallah, S.; Janardhan, A.

1996-02-01T23:59:59.000Z

126

LPG--a direct source of C/sub 3/-C/sub 4/ olefins  

SciTech Connect

This article describes the selective production of olefins by the catalytic dehydrogenation of the corresponding paraffins by means of UOP's Oleflex process. In this process, propylene can be obtained at about 85 mol % selectivity by the catalytic dehydrogenation of propane. Isobutylene can be obtained at selectivities in excess of 90 mol % from isobutane, and n-butenes (1-butene plus 2-butene) at about 80 mol % from n-butane. The availability of this technology, coupled with an abundant supply of LPG (C/sub 3/ and C/sub 4/ paraffins), opens new avenues for the selective production of propylene and butylenes.

Pujado, P.R.; Berg, R.C.; Vora, B.V.

1983-03-28T23:59:59.000Z

127

Planning and care mark repair of 14-year old leak in Kuwait Oil Co. LPG tank 95  

SciTech Connect

This paper points out that the leak, which had been present for such a long time, completely saturated the perlite insulation with hydrocarbons, thus rendering the entire operation of inspection, repair, and maintenance of the inner tank a hazardous operation. It emphasizes the safety aspects, which were complicated by the saturated perlite as well as by the fact that the tank is situated in the middle of the LPG storage area with LPG tanks on either side. Tank design, making preparations, inspection, and repair are discussed. The fact that the leaking flanges were originally installed damaged, indicated the future need of tighter company quality control of all contractors work.

Shtayieh, S.

1983-01-10T23:59:59.000Z

128

Evaluation of aftermarket fuel delivery systems for natural gas and LPG vehicles  

DOE Green Energy (OSTI)

This study was designed to evaluate the effectiveness of aftermarket fuel delivery systems for vehicles fueled by compressed natural gas (CNG) and liquefied petroleum gas (LPG). Most of the CNG and LPG vehicles studied were converted to the alternative fuel after purchase. There are wide variations in the quality of the conversion hardware and the installation. This leads to questions about the overall quality of the converted vehicles, in terms of emissions, safety, and performance. There is a considerable body of emissions data for converted light-duty vehicles, and a smaller amount for medium- and heavy-duty vehicles. However, very few of these data involve real world conditions, and there is growing concern about in-use emissions. This report also attempts to assess factors that could allow in-use emissions to vary from the best-case'' results normally reported. The study also addresses issues of fuel supply, fuel composition, performance, safety, and warranty waivers. The report is based on an extensive literature and product survey and on the author's experience with fuel delivery systems for light-duty vehicles.

Willson, B. (Colorado State Univ., Fort Collins, CO (United States))

1992-09-01T23:59:59.000Z

129

Evaluation of aftermarket fuel delivery systems for natural gas and LPG vehicles  

DOE Green Energy (OSTI)

This study was designed to evaluate the effectiveness of aftermarket fuel delivery systems for vehicles fueled by compressed natural gas (CNG) and liquefied petroleum gas (LPG). Most of the CNG and LPG vehicles studied were converted to the alternative fuel after purchase. There are wide variations in the quality of the conversion hardware and the installation. This leads to questions about the overall quality of the converted vehicles, in terms of emissions, safety, and performance. There is a considerable body of emissions data for converted light-duty vehicles, and a smaller amount for medium- and heavy-duty vehicles. However, very few of these data involve real world conditions, and there is growing concern about in-use emissions. This report also attempts to assess factors that could allow in-use emissions to vary from the ``best-case`` results normally reported. The study also addresses issues of fuel supply, fuel composition, performance, safety, and warranty waivers. The report is based on an extensive literature and product survey and on the author`s experience with fuel delivery systems for light-duty vehicles.

Willson, B. [Colorado State Univ., Fort Collins, CO (United States)

1992-09-01T23:59:59.000Z

130

Evaluation of aftermarket fuel delivery systems for natural gas and LPG vehicles  

SciTech Connect

This study was designed to evaluate the effectiveness of aftermarket fuel delivery systems for vehicles fueled by compressed natural gas (CNG) and liquefied petroleum gas (LPG). Most of the CNG and LPG vehicles studied were converted to the alternative fuel after purchase. There are wide variations in the quality of the conversion hardware and the installation. This leads to questions about the overall quality of the converted vehicles, in terms of emissions, safety, and performance. There is a considerable body of emissions data for converted light-duty vehicles, and a smaller amount for medium- and heavy-duty vehicles. However, very few of these data involve real world conditions, and there is growing concern about in-use emissions. This report also attempts to assess factors that could allow in-use emissions to vary from the best-case'' results normally reported. The study also addresses issues of fuel supply, fuel composition, performance, safety, and warranty waivers. The report is based on an extensive literature and product survey and on the author's experience with fuel delivery systems for light-duty vehicles.

Willson, B. (Colorado State Univ., Fort Collins, CO (United States))

1992-09-01T23:59:59.000Z

131

New concept: deepwater NGL/LPG plant. [Natural gas liquids and liquefied petroleum gas  

SciTech Connect

Floating platforms for processing natural gas liquids and liquefied petroleum gas (NGL/LPG) need to be stable for the processing and transfer of the products. Floating platforms are economically more attractive for producing marginal fields in deeper waters. Most of the proposed designs for crude oil and natural gas production have been tension-leg platforms, but 3 Norwegian companies are offering a converted ship as an alternative. The 3 companies will used a ship fitted with pontoons that can be raised and lowered to increase the vessel's stability. The NGL/LPG system was designed for a North Sea oil field. The feasibility study which the 3 companies completed was for a liquefaction and storage ship with a capacity of 75,000 cu m. The joint venture feels a ship has several advantages: large payload capacity; large storage capacity; ample deck space for equipment; easy to maintain; can be drydocked if necessary; and has a lower building cost. The 2 key elements to the system are the stabilization system and the turret platform.

1978-12-01T23:59:59.000Z

132

Six years' operating experience at Ardjuna field helps prove out LPG SBS system  

SciTech Connect

The permanent yoke mooring system and the two-product flexpipe riser of the Arjuna Sakti LPG storage barge have completely lived up to their expectations. The LPG offtake system, the terminaling function of the storage unit, has also performed extremely well. Experience gained at Ardjuna provides confidence for future openocean mooring of large methanol or LNG plants. Mooring systems of these future units will likely have a different configuration, such as the single anchor leg storage (SALS) mooring. However, the basic system components have been used, both at Ardjuna and in comparable situations elsewhere in the world. Engineers who are working on floating, large scale, gas processing plants for mooring in the open ocean could profitably join their efforts in a team comprised of process specialists, naval architects, and mooring experts. Specific areas of consideration should be: length-to-beam and lengthto-depth ratios and shape of bow. This could result in a storage/process barge design with better motion characteristics and lower mooring forces than proposed at present.

Smulders, L.H.

1983-02-21T23:59:59.000Z

133

Chemically reactive coatings for passive fire protection in LNG and LPG storage and transporation  

SciTech Connect

According to Van Dyke Associates and TSI Inc., supporting and containing steels used to store and transport LNG and LPG are best protected in case of fire by thermally reactive subliming compounds. When exposed to fire, such compounds undergo an endothermic reaction; thus the substrate material beneath the coating will not heat up beyond the temperature at which this reaction occurs. Gases released by the sublimation reaction pass outward through the pores of the char, breaking down further as they absorb more energy. Numerous tests confirm that in comparison with other types of coatings, subliming compounds require the smallest thickness of coating for any specified level of protection. Routine spraying application techniques further reduce the cost of this passive fire-protection method.

Van Dyke, B.H.; Kawaller, S.T.

1979-01-01T23:59:59.000Z

134

Vaporization, dispersion, and radiant fluxes from LPG spills. Final technical report  

SciTech Connect

Both burning and non-burning spills of LPG (primarily propane) were studied. Vaporization rates for propane spills on soil, concrete, insulating concrete, asphalt, sod, wood, and polymer foams were measured. Thermal conductivity, heat transfer coefficients, and steady state vaporization rates were determined. Vapor concentrations were measured downwind of open propane pools and a Gaussian dispersion model modified for area sources provided a good correlation of measured concentrations. Emitted and incident radiant fluxes from propane fires were measured. Simplified flame radiation models were adequate for predicting radiant fluxes. Tests in which propane was sprayed into the air showed that at moderately high spray rates all the propane flashed to vapor or atomized; no liquid collected on the ground.

1982-05-01T23:59:59.000Z

135

Nonresidential buildings energy consumption survey: 1979 consumption and expenditures. Part 2. Steam, fuel oil, LPG, and all fuels  

Science Conference Proceedings (OSTI)

This report presents data on square footage and on total energy consumption and expenditures for commercial buildings in the contiguous United States. Also included are detailed consumption and expenditures tables for fuel oil or kerosene, liquid petroleum gas (LPG), and purchased steam. Commercial buildings include all nonresidential buildings with the exception of those where industrial activities occupy more of the total square footage than any other type of activity. 7 figures, 23 tables.

Patinkin, L.

1983-12-01T23:59:59.000Z

136

Humidity Control in Residences  

E-Print Network (OSTI)

Maintaining relative humidity below 60% for residential houses in humid climates promotes a healthy indoor environment. Yet, for such homes, these lower humidity levels are difficult to maintain with conventional recirculation air conditioning units. By introducing a separate vapor compression unit to pre-condition outside air, indoor relative humidity can be controlled. This new air conditioning system combines a ventilation unit with a conventional recirculation air conditioning unit. Although successful in maintaining indoor humidity levels below 60%, the new air conditioning system will require more electric energy to provide the additional dehumidification. However, this penalty is shown to be offset by reductions in sensible load during a summer week, which should result in lower energy consumption and peak electric demand during that period. The performance of this new air conditioning system is demonstrated using FSEC 3.0, a building energy simulation program developed by the Florida Solar Energy Center, to simulate the heat and moisture transport occurring within a prototypical residence located in Austin, Texas.

Trowbridge, J.; Peterson, J.

1994-01-01T23:59:59.000Z

137

Clean air program: Design guidelines for bus transit systems using liquefied petroleum gas (LPG) as an alternative fuel. Final report, July 1995-April 1996  

Science Conference Proceedings (OSTI)

The Federal Transit Administration (FTA) has initiated the development of `Design Guidelines for Bus Transit Systems Using Alternative Fuels.` This report provides design guidelines for the safe uses of Liquefied Petroleum Gas (LPG). It forms a part of the series of individual monographs being published by the FTA on (the guidelines for the safe use of) Compressed Natural Gas (CNG), Liquefied Natural Gas (LNG), Liquefied Petroleum Gas (LPG) and alcohol fuels (Methanol and Ethanol). Each report in this series describes for the subject fuel the important fuel properties, guidelines for the design and operation of bus fueling, storage and maintenance facilities, issues on personnel training and emergency preparedness.

Raj, P.K.; Hathaway, W.T.; Kangas, R.

1996-09-01T23:59:59.000Z

138

Cr-free Fe-based metal oxide catalysts for high temperature water gas shift reaction of fuel processor using LPG  

Science Conference Proceedings (OSTI)

The goal of this study was to identify the most suitable chromium-free iron-based catalysts for the HTS (high temperature shift) reaction of a fuel processor using LPG. Hexavalent chromium (Cr6+) in the commercial HTS catalyst has been regarded as hazardous material. We selected Ni and Co as the substitution for chromium in the Fe-based HTS catalyst and investigated the HTS activities of these Crfree catalysts at LPG reformate condition. Cr-free Fe-based catalysts which contain Ni, Zn, or Co instead of Cr were prepared by coprecipitation method and the performance of the catalysts in HTS was evaluated under gas mixture conditions (42% H2, 10% CO, 37% H2O, 8% CO2, and 3% CH4; R (reduction factor): about 1.2) similar to the gases from steam reforming of LPG (100% conversion at steam/carbon ratio = 3), which is higher than R (under 1) of typically studied LNG reformate condition. Among the prepared Cr-free Febased catalysts, the 5 wt%-Co/Fe/20 wt%-Ni and 5 wt%-Zn/Fe/20 wt%-Ni catalysts showed good catalytic activity under this reaction condition simulating LPG reformate gas.

lee, Joon Y.; Lee, Dae-Won; Lee, Kwan Young; Wang, Yong

2009-08-15T23:59:59.000Z

139

ALS Doctoral Fellowship in Residence  

NLE Websites -- All DOE Office Websites (Extended Search)

Doctoral Fellowship in Residence Print Doctoral Fellowship in Residence Print The Advanced Light Source (ALS), a division of Lawrence Berkeley National Laboratory, is a national user facility that generates intense x-ray radiation for scientific and technological research. As the world's first third-generation synchrotron radiation source, the ALS offers outstanding performance in the VUV-soft x-ray energy range and excellent performance into the hard x-ray region. The facility welcomes researchers from universities, industries, and government laboratories around the world. It is funded by the U.S. Department of Energy, Office of Basic Energy Sciences. Applications to Shape the Future of Synchrotron Radiation Science Synchrotron radiation is now an established tool in many areas of physical and biological science. The ALS Doctoral Fellowships will allow beginning researchers to work at the frontier of synchrotron radiation research and to help advance state-of-the-art applications.

140

Energy-Efficient Residence Hall  

E-Print Network (OSTI)

Recently, there has been an increase in the number of energy efficient buildings in the U.S. We want to encourage this green movement by providing people with a simple and systematic Stairwell Closable vents leading from the floor to the stairwell along with windows in the stairwell leading outside act as a thermal chimney which gets rid of excess heat. approach for green building construction. Our project focuses on creating a guideline for an energy-efficient residence hall. We have looked into energy-efficient and eco-friendly lighting, heating, insulation, and other aspects that integrate into a green building. Our guideline, as a result, will aid colleges in the Worcester community to design and construct green residence halls.

Giselle Chen; Nathaniel Eames; Andrew Holmes; Grant Wong; Advisor David Spanagel (humanities; Arts Department

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Energy efficient residence: research results  

Science Conference Proceedings (OSTI)

This report on the design, construction, and monitoring of an energy efficient residence and a conventional comparison home by the National Association of Home Builders Research Foundation, Inc. The report describes the two homes in considerable detail, summarizes the results of the energy and other measurements, and evaluates many of the energy conservation techniques used. Finally, these results are synthesized with the foundation's other energy conservation experience into two lists of energy saving design tips for homes in both colder and warmer climates. Most of the design tips are accompanied by brief comments intended to aid in their interpretation and use.

Johnson, R.J.

1980-12-01T23:59:59.000Z

142

A survey of dermatology residency program directors' views on mentorship  

E-Print Network (OSTI)

directors of residency training programs have an importantgiven residency training program. This study was undertakenacademic residency training programs in the United States.

Donovan, Jeff

2009-01-01T23:59:59.000Z

143

Variable residence time vortex combustor  

DOE Patents (OSTI)

A variable residence time vortex combustor including a primary combustion chamber for containing a combustion vortex, and a plurality of louvres peripherally disposed about the primary combustion chamber and longitudinally distributed along its primary axis. The louvres are inclined to impel air about the primary combustion chamber to cool its interior surfaces and to impel air inwardly to assist in driving the combustion vortex in a first rotational direction and to feed combustion in the primary combustion chamber. The vortex combustor also includes a second combustion chamber having a secondary zone and a narrowed waist region in the primary combustion chamber interconnecting the output of the primary combustion chamber with the secondary zone for passing only lower density particles and trapping higher density particles in the combustion vortex in the primary combustion chamber for substantial combustion.

Melconian, Jerry O. (76 Beaver Rd., Reading, MA 01867)

1987-01-01T23:59:59.000Z

144

Humidity fluctuations in solar greenhouse-residences  

SciTech Connect

The thermal performance of solar greenhouse-residences is well-documented. Data concerning temperature fluctuations and horticultural yield are obtainable and provide a clear picture of greenhouse-residence temperature extremes. However, both human comfort and plant growing environment are not dependent upon temperature alone. Air movement, radiation, and humidity are other criteria that can influence thermal comfort and growing conditions. The effect a vegetable peoducing greenhouse has on thermal comfort of an adjoining residence is illustrated in terms of temperature and humidity. An analysis of dewpoint conditions will further indicate the effect of moisture within the individual components. A solar greenhouse-residence with an integrated heating collection and distribution system exhibited higher internal humidities than conventional housing. The greenhouse exhibited greater diurnal swings than the adjoining residence. Transfer of moisture occurred from greenhouse to residence and caused infrequent dewpoint levels in the house. An analysis of two such buildings indicated a higher average relative humidity in the solar greenhouse-residence over conventional housing in the southeast.

Davis, M.A. (Clemson Univ., SC); Harrison, R.E.; Godbey, L.C.

1981-01-01T23:59:59.000Z

145

Landi-Hartog U. S. A. adjusts to the U. S. market. [Marketing of LPG carburetor systems for using propane as an automotive fuel  

SciTech Connect

Landi-Hartog U.S.A. has adjusted to the U.S. market in providing LPG carburetor systems for passenger cars. Landi-Hartog (LH) had to completely redesign the components on the system to be compatible with U.S. 300-525 cu in. engines. The company has California Air Resources Board approval for 300 cu in. engines and above in dual-fuel service. However, the U.S. market will remain severely restricted unless basic distribution (and the political) changes are made. The U.S. is st

1980-10-01T23:59:59.000Z

146

Advantages of a Three-Year Residency  

E-Print Network (OSTI)

resident is still in a training program. On balance, givenyear to three-year training programs, there is no data toIn most four-year training programs, the supervision of

Langdorf, Mark; Lotfipour, Shahram

2004-01-01T23:59:59.000Z

147

Volume Transfer, LPG Prover  

Science Conference Proceedings (OSTI)

... the prover is drained for a 30 ( 5) second period after cessation of the main flow. ... 87, i, Include a Pressure Correction Table 1 and Chart with your ...

2013-05-22T23:59:59.000Z

148

Does the Air-Conditioning Engineering Rubric Work in Residences...  

NLE Websites -- All DOE Office Websites (Extended Search)

Does the Air-Conditioning Engineering Rubric Work in Residences? Title Does the Air-Conditioning Engineering Rubric Work in Residences? Publication Type Conference Paper LBNL...

149

A Survey of Graduating Emergency Medicine Residents Experience with Cricothyrotomy  

E-Print Network (OSTI)

Residency Review Committee (RRC) for EM stipulates that aFor this reason, the RRC for EM requires each resident to

Makowski, Andrew L.

2013-01-01T23:59:59.000Z

150

Variability in Ultrasound Education among Emergency Medicine Residencies  

E-Print Network (OSTI)

the responding programs offer training in 13 applications.of residency training; however, only 15 programs respondedemergency ultrasound training or how residency programs have

Ahern, Matthew; Mallin, Michael P; Weitzel, Scott; Madsen, Troy; Hunt, Pat

2010-01-01T23:59:59.000Z

151

Management Training for Pathology Residents: A Regional Approach  

E-Print Network (OSTI)

Most residency training programs do not have faculty membersdidactic management training program for the residents fromdue burden on any single training program. Methods. Faculty

Wagar, E A

2004-01-01T23:59:59.000Z

152

Management Training for Pathology Residents: A Regional Approach  

E-Print Network (OSTI)

Mentor based management training. Am J Clin Pathol. 1997:WH, Healy JC. Informatics training in pathology residencyJanuary 2004 Management Training for Pathology Residents

Wagar, E A

2004-01-01T23:59:59.000Z

153

Results of the 2005-2008 Association of Residents in Radiation Oncology Survey of Chief Residents in the United States: Clinical Training and Resident Working Conditions  

Science Conference Proceedings (OSTI)

Purpose: To document clinical training and resident working conditions reported by chief residents during their residency. Methods and Materials: During the academic years 2005 to 2006, 2006 to 2007, and 2007 to 2008, the Association of Residents in Radiation Oncology conducted a nationwide survey of all radiation oncology chief residents in the United States. Chi-square statistics were used to assess changes in clinical training and resident working conditions over time. Results: Surveys were completed by representatives from 55 programs (response rate, 71.4%) in 2005 to 2006, 60 programs (75.9%) in 2006 to 2007, and 74 programs (93.7%) in 2007 to 2008. Nearly all chief residents reported receiving adequate clinical experience in commonly treated disease sites, such as breast and genitourinary malignancies; and commonly performed procedures, such as three-dimensional conformal radiotherapy and intensity-modulated radiotherapy. Clinical experience in extracranial stereotactic radiotherapy increased over time (p capital costs, such as particle beam therapy and intraoperative radiotherapy, and infrequent clinical use, such as head and neck brachytherapy, were limited to a minority of institutions. Most residency programs associated with at least one satellite facility have incorporated resident rotations into their clinical training, and the majority of residents at these programs find them valuable experiences. The majority of residents reported working 60 or fewer hours per week on required clinical duties. Conclusions: Trends in clinical training and resident working conditions over 3 years are documented to allow residents and program directors to assess their residency training.

Gondi, Vinai, E-mail: gondi@humonc.wisc.edu [Department of Radiation Oncology, University of Wisconsin Comprehensive Cancer Center, Madison, Wisconsin (United States); Bernard, Johnny Ray [Mayo Clinic Jacksonville, Jacksonville, Florida (United States); Jabbari, Siavash [University of California San Francisco, San Francisco, California (United States); Keam, Jennifer [Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Amorim Bernstein, Karen L. de [Albert Einstein College of Medicine, Bronx, New York (United States); Dad, Luqman K. [SUNY Roswell Park Cancer Institute, Buffalo, New York (United States); Li, Linna [Fox Chase Cancer Center, Philadelphia, Pennsylvania (United States); Poppe, Matthew M. [University of Utah Huntsman Cancer Hospital (United States); Strauss, Jonathan B. [Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States); Chollet, Casey T. [Loyola University Medical Center, Maywood, Illinois (United States)

2011-11-15T23:59:59.000Z

154

Establishing a Residence for a Relocation Incentive  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4, 2010 4, 2010 MEMORANDUM FOR HUMAN RESOURCES DIRECTORS c:::::::;...-~ l-- -- FROM: SARAH J. ILLA, DIRECTOR OFFICE OF MAN CAPITAL MANAGEMENT OFFICE OF THE CHIEF HUMAN CAPITAL OFFICER SUBJECT: POLICY GUIDANCE MEMORANDUM #14: ESTABLISHING A RESIDENCE FOR A RELOCATION INCENTIVE An employee who is relocating to a new commuting area must establish a temporary or permanent residence before s/he is eligible for a payment of a relocation incentive. Neither OPM's regulations or guidance nor GSA's Federal Travel Regulation address this issue. DOE guidance is as follows. This guidance will be incorporated in the DOE Handbook on Recruitment and Retention Incentives as an appendix during the next update. Temporary Residence. a. For a temporary change of station (TeS) of at least 6 months, but not more than 30

155

2009 Canadian Radiation Oncology Resident Survey  

SciTech Connect

Purpose: Statistics from the Canadian post-MD education registry show that numbers of Canadian radiation oncology (RO) trainees have risen from 62 in 1999 to approximately 150 per year between 2003 and 2009, contributing to the current perceived downturn in employment opportunities for radiation oncologists in Canada. When last surveyed in 2003, Canadian RO residents identified job availability as their main concern. Our objective was to survey current Canadian RO residents on their training and career plans. Methods and Materials: Trainees from the 13 Canadian residency programs using the national matching service were sought. Potential respondents were identified through individual program directors or chief resident and were e-mailed a secure link to an online survey. Descriptive statistics were used to report responses. Results: The eligible response rate was 53% (83/156). Similar to the 2003 survey, respondents generally expressed high satisfaction with their programs and specialty. The most frequently expressed perceived weakness in their training differed from 2003, with 46.5% of current respondents feeling unprepared to enter the job market. 72% plan on pursuing a postresidency fellowship. Most respondents intend to practice in Canada. Fewer than 20% of respondents believe that there is a strong demand for radiation oncologists in Canada. Conclusions: Respondents to the current survey expressed significant satisfaction with their career choice and training program. However, differences exist compared with the 2003 survey, including the current perceived lack of demand for radiation oncologists in Canada.

Debenham, Brock, E-mail: debenham@ualberta.net [Department of Radiation Oncology, Cross Cancer Institute, University of Alberta, Edmonton, Alberta (Canada); Banerjee, Robyn [Department of Radiation Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, Alberta (Canada); Fairchild, Alysa; Dundas, George [Department of Radiation Oncology, Cross Cancer Institute, University of Alberta, Edmonton, Alberta (Canada); Trotter, Theresa [Department of Radiation Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, Alberta (Canada); Yee, Don [Department of Radiation Oncology, Cross Cancer Institute, University of Alberta, Edmonton, Alberta (Canada)

2012-03-15T23:59:59.000Z

156

Better Buildings Neighborhood Program: Residents Learn to Open...  

NLE Websites -- All DOE Office Websites (Extended Search)

Residents Learn to Open Their Doors to Energy Efficiency in Michigan to someone by E-mail Share Better Buildings Neighborhood Program: Residents Learn to Open Their Doors to Energy...

157

ENERGY STAR Score for Residence Halls/Dormitories  

NLE Websites -- All DOE Office Websites (Extended Search)

Residence HallsDormitories in the United States Page 1 ENERGY STAR Score for Residence HallsDormitories in the United States Technical Reference OVERVIEW The ENERGY STAR Score...

158

Results of the 2003 Association of Residents in Radiation Oncology (ARRO) surveys of residents and chief residents in the United States  

Science Conference Proceedings (OSTI)

Purpose: To document demographic characteristics of current residents, career motivations and aspirations, and training program policies and resources. Methods: In 2003, the Association of Residents in Radiation Oncology (ARRO) conducted two nationwide surveys: one of all U.S. radiation oncology residents and one of chief residents. Results: The Chief Residents' Survey was completed by representatives from all 77 programs (response rate, 100%). The Residents' Survey was returned by 229 respondents (response rate, 44%). In each, 32% of respondents were female. The most popular career after residency was private practice (46%), followed by permanent academic practice (28%). Changes that would entice those choosing private practice to consider an academic career included more research experience as a resident (76%), higher likelihood of tenure (69%), lesser time commitment (66%), and higher salary (54%). Although the majority of respondents were satisfied with educational experience overall, a number of programs were reported to provide fewer resources than required. Conclusions: Median program resources and numbers of outliers are documented to allow residents and program directors to assess the relative adequacy of experience in their own programs. Policy-making bodies and individual programs should consider these results when developing interventions to improve educational experiences of residents and to increase retention of radiation oncologists in academic practice.

Jagsi, Reshma [Massachusetts General Hospital, Boston, MA (United States); Buck, David A. [Medical College of Virginia, Richmond, VA (United States); Singh, Anurag K. [Washington University, Seattle, WA (United States); Engleman, Mark [Northwestern University, Chicago, IL (United States); Thakkar, Vipul [Cleveland Clinic, Cleveland, OH (United States); Frank, Steven J. [University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Flynn, Daniel [Holy Family Hospital, Methuen, MA (United States)

2005-03-01T23:59:59.000Z

159

Medical Resident Medicare Tax Refund Claims University of California  

E-Print Network (OSTI)

1 Medical Resident Medicare Tax Refund Claims University of California April 30, 2013 On March 2 portion of FICA taxes paid for medical residents prior to April 1, 2005, so long as the employer the requisite filings on behalf of its medical schools, medical centers, and residents for tax periods dating

Russell, Lynn

160

Controlled short residence time coal liquefaction process  

DOE Patents (OSTI)

Normally solid dissolved coal product and a distillate liquid product are produced by continuously passing a feed slurry comprising raw feed coal and a recycle solvent oil and/or slurry together with hydrogen to a preheating-reaction zone (26, alone, or 26 together with 42), the hydrogen pressure in the preheating-reaction zone being at least 1500 psig (105 kg/cm.sup.2), reacting the slurry in the preheating-reaction zone (26, or 26 with 42) at a temperature in the range of between about 455.degree. and about 500.degree. C. to dissolve the coal to form normally liquid coal and normally solid dissolved coal. A total slurry residence time is maintained in the reaction zone ranging from a finite value from about 0 to about 0.2 hour, and reaction effluent is continuously and directly contacted with a quenching fluid (40, 68) to substantially immediately reduce the temperature of the reaction effluent to below 425.degree. C. to substantially inhibit polymerization so that the yield of insoluble organic matter comprises less than 9 weight percent of said feed coal on a moisture-free basis. The reaction is performed under conditions of temperature, hydrogen pressure and residence time such that the quantity of distillate liquid boiling within the range C.sub.5 -455.degree. C. is an amount at least equal to that obtainable by performing the process under the same conditions except for a longer total slurry residence time, e.g., 0.3 hour. Solvent boiling range liquid is separated from the reaction effluent and recycled as process solvent.

Anderson, Raymond P. (Overland Park, KS); Schmalzer, David K. (Englewood, CO); Wright, Charles H. (Overland Park, KS)

1982-05-04T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Are Simulation Stethoscopes a Useful Adjunct for Emergency Medicine Residents Training on High-fidelity Mannequins?  

E-Print Network (OSTI)

of a simulator in training anesthesiology residents. Acadal. Simulation-based training of internal medicine residentsEmergency Residents Training on High-fidelity Mannequins?

Warrington, Steven Jay; Beeson, Michael S; Fire, Frank L

2013-01-01T23:59:59.000Z

162

The prime curriculum - Clinical research training during residency  

E-Print Network (OSTI)

U C AT I O N The Prime Curriculum Clinical Research TrainingDESCRIPTION: The PRIME curriculum utilizes didactic lecture,and educators, our curriculum affords residents the

Kohlwes, R J; Shunk, R L; Avins, A; Garber, J; Bent, S; Shlipak, M G

2006-01-01T23:59:59.000Z

163

Behavior, comfort, and energy consumption in student residence halls.  

E-Print Network (OSTI)

??New residence halls differ from their predecessors because of sophisticated systems, concern for energy efficiency, and attention to student satisfaction. Nevertheless, older facilities represent the (more)

Collins, Thomas Daniel, 1979-

2010-01-01T23:59:59.000Z

164

THE RESIDENTS' STUDENTS ARE ADVISED TO KEEP THIS BOOKLET  

E-Print Network (OSTI)

THE RESIDENTS' HANDBOOK 2010/2011 STUDENTS ARE ADVISED TO KEEP THIS BOOKLET FOR FUTURE REFERENCE in the Conditions of Occupancy and the Residents' Handbook which are available at the following web locations: http://www.tcd.ie/accommodationandcatering/PDF/conditionsofoccup1011.pdf http://www.tcd.ie//accommodationandcatering/PDF/Handbook1011.pdf Timothy J Trimble, Junior

O'Mahony, Donal E.

165

Nonprofit Helps Kansas City Residents Conserve Energy | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nonprofit Helps Kansas City Residents Conserve Energy Nonprofit Helps Kansas City Residents Conserve Energy Nonprofit Helps Kansas City Residents Conserve Energy April 30, 2010 - 2:32pm Addthis Metropolitan Energy Center helps Kansas City residents manage and control their energy use. | File illustration Metropolitan Energy Center helps Kansas City residents manage and control their energy use. | File illustration Stephen Graff Former Writer & editor for Energy Empowers, EERE To make her home energy efficient, the first thing Rita Norton had to do was "tighten the envelope." That meant stuffing more insulation between her walls and sealing cracks at the foundation to keep any unwanted air from sneaking in or valuable air from seeping out. "That's the phrase they call it," says the former

166

Establishing a Residence for a Relocation Incentive | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Establishing a Residence for a Relocation Incentive Establishing a Residence for a Relocation Incentive Establishing a Residence for a Relocation Incentive POLICY GUIDANCE MEMORANDUM #14: An employee who is relocating to a new commuting area must establish a temporary or permanent residence before s/he is eligible for a payment of a relocation incentive. Neither OPM's regulations or guidance nor GSA's Federal Travel Regulation address this issue. DOE guidance is as follows. This guidance will be incorporated in the DOE Handbook on Recruitment and Retention Incentives as an appendix during the next update. Establishing a Residence for a Relocation Incentive Responsible Contacts Bruce Murray HR Policy Advisor E-mail bruce.murray@hq.doe.gov Phone 202-586-3372 More Documents & Publications DOE Handbook on Recruitment and Retention Incentives

167

Establishing a Residence for a Relocation Incentive | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Establishing a Residence for a Relocation Incentive Establishing a Residence for a Relocation Incentive Establishing a Residence for a Relocation Incentive POLICY GUIDANCE MEMORANDUM #14: An employee who is relocating to a new commuting area must establish a temporary or permanent residence before s/he is eligible for a payment of a relocation incentive. Neither OPM's regulations or guidance nor GSA's Federal Travel Regulation address this issue. DOE guidance is as follows. This guidance will be incorporated in the DOE Handbook on Recruitment and Retention Incentives as an appendix during the next update. Establishing a Residence for a Relocation Incentive Responsible Contacts Bruce Murray HR Policy Advisor E-mail bruce.murray@hq.doe.gov Phone 202-586-3372 More Documents & Publications FAQ: Relocation Expenses

168

Florida Residents See Energy Bill Reductions | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Florida Residents See Energy Bill Reductions Florida Residents See Energy Bill Reductions Florida Residents See Energy Bill Reductions January 27, 2010 - 3:42pm Addthis Indiantown, Florida, has a lot of small-town charm. Its 7,000 residents have acres of citrus groves but only one traffic light in the town. It might be small in size, but Indiantown Non-Profit Housing is making quite an impact across its region. This nonprofit weatherizes the homes of qualifying residents free of charge, and demand for its services is on the rise. "One of the best outcomes is that we can hire additional employees" says Director Donna Carman, referring to the $5.2 million in Recovery Act funds Indiantown Non-Profit Housing has received. The staff has more than doubled from five to 16, meaning that Floridians like 72-year-old Edith

169

Stand-alone solar residence and solar electric auto  

Science Conference Proceedings (OSTI)

In a system design recently patented (US Patent No. 4,182,960, Integrated Residential and Automotive (Solar) Energy System, issued January 8, 1980). a passive solar residence first is equipped with photovoltaic arrays to charge both the residence and an electric auto. Then, a liquid-fueled engine/generator on board the auto both (1) extends the range of the electric auto and (2) enables the auto with its engine/generator to serve as a backup source of heat and electricity for the residence.

Reuyl, J.S.

1980-01-01T23:59:59.000Z

170

Van Norman Residences Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Norman Residences Space Heating Low Temperature Geothermal Facility Norman Residences Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Van Norman Residences Space Heating Low Temperature Geothermal Facility Facility Van Norman Residences Sector Geothermal energy Type Space Heating Location Thermopolis, Wyoming Coordinates 43.6460672°, -108.2120432° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

171

Mississippi Residents Save Through Appliance Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residents Save Through Appliance Rebate Program Residents Save Through Appliance Rebate Program Mississippi Residents Save Through Appliance Rebate Program October 27, 2010 - 11:39am Addthis Mississippi's Cowboy Maloney stores saw increases of up to 90 percent on front-loading washing machines in April. | Photo courtesy of Flickr user Andrew Kelsall via the Creative Commons license Mississippi's Cowboy Maloney stores saw increases of up to 90 percent on front-loading washing machines in April. | Photo courtesy of Flickr user Andrew Kelsall via the Creative Commons license Lindsay Gsell What are the key facts? Mississippi rebate program issues 37,430 rebates to residents. Recovery Act helped consumers conserve energy and save millions of dollars. Program demand helps one Mississippi retailer see 90% increase in

172

Vale Residences Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Residences Space Heating Low Temperature Geothermal Facility Residences Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Vale Residences Space Heating Low Temperature Geothermal Facility Facility Vale Residences Sector Geothermal energy Type Space Heating Location Vale, Oregon Coordinates 43.9821055°, -117.2382311° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

173

Lakeview Residences Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Lakeview Residences Space Heating Low Temperature Geothermal Facility Lakeview Residences Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Lakeview Residences Space Heating Low Temperature Geothermal Facility Facility Lakeview Residences Sector Geothermal energy Type Space Heating Location Lakeview, Oregon Coordinates 42.1887721°, -120.345792° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

174

Nonprofit Helps Kansas City Residents Conserve Energy | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

years, MEC has fielded more and more calls from residents like Rita who want energy audits and upgrades to their homes. The organization went from six contractors doing 150 jobs...

175

Don ' t forget to read your Residence Student Handbook  

E-Print Network (OSTI)

and light bulbs are available free of charge from your RA or the Alumni front desk! Clark Residence Clark comes fully equipped with a single bed and mattress, a desk (with study light, hutch and shelf included

176

Developing resident leadership : theory and practice in Boston's neighborhoods  

E-Print Network (OSTI)

For decades, Boston residents have worked together and organized to strengthen and protect their neighborhoods, often in response to encroaching government policy and local development. The South End's Villa Victoria housing ...

Alleyne, Kim L

2005-01-01T23:59:59.000Z

177

Decision Making by Austin, Texas, Residents in Hypothetical Tornado Scenarios  

Science Conference Proceedings (OSTI)

One of the goals of the Warning Project is to understand how people receive warnings of hazardous weather and subsequently use this information to make decisions. As part of the project, 519 surveys from Austin, Texas, floodplain residents were ...

David M. Schultz; Eve C. Gruntfest; Mary H. Hayden; Charles C. Benight; Sheldon Drobot; Lindsey R. Barnes

2010-07-01T23:59:59.000Z

178

Klamath Residence (500) Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Residence (500) Space Heating Low Temperature Geothermal Facility Residence (500) Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Klamath Residence (500) Space Heating Low Temperature Geothermal Facility Facility Klamath Residence (500) Sector Geothermal energy Type Space Heating Location Klamath Falls, Oregon Coordinates 42.224867°, -121.7816704° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

179

DOE's Entrepreneur in Residence (EIR) Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Entrepreneur in Residence (EIR) Program Entrepreneur in Residence (EIR) Program DOE's Entrepreneur in Residence (EIR) Program October 24, 2007 - 3:45pm Addthis "It is in our vital interest to diversify America's energy supply - and the way forward is through technology." - President George W. Bush, 2007 State of the Union Address DOE's Commercialization Team The Commercialization Team is focused on broad market adoption of clean energy technologies. Crucial to this effort, is supporting the move of these technologies from DOE's National Laboratories to the private sector. About the EIR Program The Entrepreneur in Residence (EIR) Program will bring venture capital sponsored entrepreneurs into three of DOE's National Laboratories to develop plans to commercialize new clean energy technologies. The

180

Issue 14: Transportation, Economy, and Crime Top Los Angeles County Residents Concerns About the Region  

E-Print Network (OSTI)

Transportation, Economy, and Crime Top LA County ResidentsTransportation, Economy, and Crime Top LA County Residentsthe economy, educa- tion, crime, and housing were the most

Haselhoff, Kim; Ong, Paul M.; Tran, Lucy

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

In-Training Practice Patterns of Combined Emergency Medicine/Internal Medicine Residents, 2003-2007  

E-Print Network (OSTI)

medicine residents during training. Ann Int Med. 2006;145:et al Table 3. Perceived training deficits of current (2008)specialty elective training during residency Administrative

Kessler, Chad S; Gonzalez, Andrew A; Stallings, Leonard A; Templeman, Todd A

2011-01-01T23:59:59.000Z

182

DOE Announces Expansion and Solicitation for Entrepreneur in Residence  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Expansion and Solicitation for Entrepreneur in Expansion and Solicitation for Entrepreneur in Residence Program DOE Announces Expansion and Solicitation for Entrepreneur in Residence Program November 19, 2008 - 4:58pm Addthis Entrepreneurs Accelerate Deployment of Advanced Clean Energy Technologies from DOE's Labs to the Marketplace WASHINGTON - U.S. Department of Energy (DOE) Secretary Samuel W. Bodman today announced a competitive solicitation for five venture capital firms to participate in the expansion of DOE's Entrepreneur in Residence (EIR) program, that aims to accelerate deployment and commercialization of advanced clean energy technologies from DOE's National Laboratories. EIR furthers President Bush's comprehensive strategy to reduce our nation's dependence on foreign oil and reduce greenhouse gas emissions by empowering

183

Educating Glendale, Arizona Residents About Energy Savings | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Educating Glendale, Arizona Residents About Energy Savings Educating Glendale, Arizona Residents About Energy Savings Educating Glendale, Arizona Residents About Energy Savings August 10, 2010 - 1:00pm Addthis A portion of Glendale, Arizona's Energy Efficiency and Conservation Block Grant was used to purchase programmable thermostats. | Department of Energy Photo | A portion of Glendale, Arizona's Energy Efficiency and Conservation Block Grant was used to purchase programmable thermostats. | Department of Energy Photo | Kevin Craft City officials in Glendale, Ariz. had a problem. Citizens were constantly asking them for information on how to reduce home energy consumption, but they did not have a staff member to answer the questions. That changed in June 2009, when the city hired Nancy Schwab to be the official energy education specialist.

184

Tallahassee Program Encourages Residents to Build Green | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tallahassee Program Encourages Residents to Build Green Tallahassee Program Encourages Residents to Build Green Tallahassee Program Encourages Residents to Build Green June 16, 2010 - 12:56pm Addthis The city of Tallahassee recently launched a Residential Green Building Program that city officials predict will help reduce the city's carbon footprint and stimulate the local economy. Cynthia Barber, executive director of Tallahassee's office of Environmental Policy and Energy Resources, says an increase in green construction will provide employment opportunities for trade specialists. "Workers, who specialize in green services, such as homebuilders and evaluators, will get more opportunities to construct green homes and carry out certifications," says Barber. "They will benefit as a result of having

185

Educating Glendale, Arizona Residents About Energy Savings | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Educating Glendale, Arizona Residents About Energy Savings Educating Glendale, Arizona Residents About Energy Savings Educating Glendale, Arizona Residents About Energy Savings August 10, 2010 - 1:00pm Addthis A portion of Glendale, Arizona's Energy Efficiency and Conservation Block Grant was used to purchase programmable thermostats. | Department of Energy Photo | A portion of Glendale, Arizona's Energy Efficiency and Conservation Block Grant was used to purchase programmable thermostats. | Department of Energy Photo | Kevin Craft City officials in Glendale, Ariz. had a problem. Citizens were constantly asking them for information on how to reduce home energy consumption, but they did not have a staff member to answer the questions. That changed in June 2009, when the city hired Nancy Schwab to be the official energy education specialist.

186

Emergency Medical Questionnaire & College Medical Registration Form This information is retained at your Residence for use by Residence staff in the event of a medical emergency  

E-Print Network (OSTI)

Emergency Medical Questionnaire & College Medical Registration Form This information is retained at your Residence for use by Residence staff in the event of a medical emergency and will be treated or a GP (General Medical Practitioner) in London who is prepared to visit them in their Residence should

Applebaum, David

187

Comparison of residence time models for cascading rotary dryers  

SciTech Connect

The predictions of the models of Matchett and Baker (1988), Saeman and Mitchell (1954) and Friedman and Marshall (1949) for the solids residence time in rotary dryers have been compared with both pilot-scale and industrial-scale data. A countercurrent pilot-scale dryer of 0.2m diameter and 2m long has been used with air velocities up to 1.5 m to measure the residence times of sorghum grain. The average discrepancy for the solids residence time between the predictions and the experiments that were carried out in the pilot-scale rotary dryer is {minus}10.4%. Compared with the models of Friedman and Marshall (1949) and Saeman and Mitchell (1954) for the pilot-scale data obtained here, the Matchett and Baker model is more satisfactory for predicting the solids residence time in this pilot-scale dryer. It has also been found that the model of Matchett and Baker describes the industrial data of Saeman and Mitchell (1954) than the correlation of Friedman and Marshall (1949).

Cao, W.F.; Langrish, T.A.G. [Univ. of Sydney, New South Wales (Australia). Dept. of Chemical Engineering

1999-04-01T23:59:59.000Z

188

Stable, Ultra-Low Residence Time Partial Oxidation  

DOE Patents (OSTI)

A process for the catalytic partial oxidation of methane in gas phase at very short residence time (800,000 to 12,000,000 hr.sup.-1) by contacting a gas stream containing methane and oxygen with a metal supported catalyst, such as platinum deposited on a ceramic monolith.

Schmidt, Lanny D. (Minneapolis, MN); Hickman, Daniel A. (Midland, MI)

1997-07-15T23:59:59.000Z

189

JAVA SWING-BASED PLOTTING PACKAGE RESIDING WITHIN XAL  

Science Conference Proceedings (OSTI)

A data plotting package residing in the XAL tools set is presented. This package is based on Java SWING, and therefore it has the same portability as Java itself. The data types for charts, bar-charts, and color-surface plots are described. The algorithms, performance, interactive capabilities, limitations, and the best usage practices of this plotting package are discussed.

Shishlo, Andrei P [ORNL; Chu, Paul [Stanford University; Pelaia II, Tom [ORNL

2007-01-01T23:59:59.000Z

190

Hazard Assessment of Chemical Air Contaminants Measured in Residences  

NLE Websites -- All DOE Office Websites (Extended Search)

Hazard Assessment of Chemical Air Contaminants Measured in Residences Hazard Assessment of Chemical Air Contaminants Measured in Residences Title Hazard Assessment of Chemical Air Contaminants Measured in Residences Publication Type Journal Article LBNL Report Number LBNL-3650E Year of Publication 2011 Authors Logue, Jennifer M., Thomas E. McKone, Max H. Sherman, and Brett C. Singer Journal Indoor Air Volume 21 Start Page 92 Issue 2 Pagination 92-109 Date Published 04/2011 Keywords resave Abstract Identifying air pollutants that pose a potential hazard indoors can facilitate exposure mitigation. In this study, we compiled summary results from 77 published studies reporting measurements of chemical pollutants were representative of concentrations in residences in the United States. These data were used to calculate representative mid-range and upper bound concentrations relevant to chronic exposures for 267 pollutants and representative peak concentrations relevant to acute exposures for 5 activity-associated pollutants. Representative concentrations are compared to available chronic and acute health standards for 97 pollutants. Fifteen pollutants are identified as contaminants of concern for chronic health effects in a large fraction of homes. Nine pollutants are identified as potential chronic health hazards in a substantial minority of homes and an additional nine are identified as potential hazards in a very small percentage of homes. Nine pollutants are identified as priority hazards based on robustness of reported concentration data and fraction of residences that appear to be impacted: acetaldehyde; acrolein; benzene; 1,3- butadiene; 1,4-dichlorobenzene; formaldehyde; naphthalene; nitrogen dioxide; and PM2.5. Activity-based emissions are shown to pose potential acute health hazards for PM2.5, formaldehyde, CO, chloroform, and NO2.

191

Sustainability Evaluation of Resident Building in Bosnia and Herzegovina  

E-Print Network (OSTI)

The energy system of resident building requires to be seen as the complex system with defined respective indicators including: economic, environmental and social indicators with respective sub-indicators. In our analysis, we will assumed that the energy system is a complex system which may interact with its surrounding by utilizing resources, exchange conversion system products, utilize economic benefits from conversion process and absorb the social consequences of conversion process. This evaluation will be based on the selection of a number of resident buildings as the potential options appropriate for the geographic, climate and cultural region. With multi-criteria method based on the selected number of indicators the sustainability index will be determined. In this evaluation attention is focused on the following resident buildings: Bosnian family house, Modern architecture dwelling, Traditional family house, Best choice of local family house. The finale result of this study will be presented in Sustainability Index rating for the options under consideration. It can be noticed that the quality of the selected objects is defined in relation to the Sustainability Index.

Zlomusica, E.; Afgan, N.

2010-01-01T23:59:59.000Z

192

Simulation of the ghost ranch greenhouse-residence  

DOE Green Energy (OSTI)

The greenhouse-residence unit of the Sundwellings Demonstration Center at Ghost Ranch, Abiguice, New Mexico, has been studied by computer modeling and simulation techniques. A thermal network model of the building has been developed in the framework of PASOLE, the Los Alamos passive solar energy simulation program. Simulation studied based on hourly weather data recorded during the 1977--78 heating season leave been done. Model validation was done by hourly comparisons of simulation predicted temperatures in the building with measured values of corresponding temperatures. The building model was used to predict a 12-month performance with the 1976--77 Los Alamos weather data. A solar fraction, the ratio of the solar portion of the residence heat input to the total heating load, was computed to be 60%. Other performance and design questions studies with 12-month Los Alamos simulation runs include the importance of the thermocirculation vents, the effect of external insulation on the residence walls, and the effect of nighttime insulation on the greenhouse glazing.

Jones, R.W.; McFarland, R.D.

1979-01-01T23:59:59.000Z

193

Optimization of Occupancy Based Demand Controlled Ventilation in Residences  

SciTech Connect

Although it has been used for many years in commercial buildings, the application of demand controlled ventilation in residences is limited. In this study we used occupant exposure to pollutants integrated over time (referred to as 'dose') as the metric to evaluate the effectiveness and air quality implications of demand controlled ventilation in residences. We looked at air quality for two situations. The first is that typically used in ventilation standards: the exposure over a long term. The second is to look at peak exposures that are associated with time variations in ventilation rates and pollutant generation. The pollutant generation had two components: a background rate associated with the building materials and furnishings and a second component related to occupants. The demand controlled ventilation system operated at a low airflow rate when the residence was unoccupied and at a high airflow rate when occupied. We used analytical solutions to the continuity equation to determine the ventilation effectiveness and the long-term chronic dose and peak acute exposure for a representative range of occupancy periods, pollutant generation rates and airflow rates. The results of the study showed that we can optimize the demand controlled airflow rates to reduce the quantity of air used for ventilation without introducing problematic acute conditions.

Mortensen, Dorthe K.; Walker, Iain S.; Sherman, Max H.

2011-05-01T23:59:59.000Z

194

Real time curriculum map for internal medicine residency  

E-Print Network (OSTI)

which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Background: To manage the voluminous formal curriculum content in a limited amount of structured teaching time, we describe the development and evaluation of a curriculum map for academic half days (AHD) in a core internal medicine residency program. Methods: We created a 3-year cyclical curriculum map (an educational tool combining the content, methodology and timetabling of structured teaching), comprising a matrix of topics under various specialties/themes and corresponding AHD hours. All topics were cross-matched against the ACP-ASIM in-training examination, and all hours were colour coded based on the categories of core competencies. Residents regularly updated the map on a real time basis. Results: There were 208 topics covered in 283 AHD hours. All topics represented core competencies with minimal duplication (78 % covered once in 3 years). Only 42 hours (15%) involved non-didactic teaching, which increased after implementation of the map (1819 hours/year versus baseline 5 hours/year). Most AHD hours (78%) focused on medical expert competencies. Resident satisfaction (90 % response) was high throughout (range 3.64 0.21, 3.84 0.14 out of 4),

Roger Y Wong; J Mark Roberts; Roger Y Wong; J Mark Roberts

2007-01-01T23:59:59.000Z

195

"Living for the City:" : the political meaning of public housing residents' extraordinary struggle  

E-Print Network (OSTI)

While the particularities of public housing residents' hardships often capture the attention of the national media, less recognized and understood is how public housing residents work to address the instabilities they ...

Green, La Tonya M. (La Tonya Mellissa), 1975-

2012-01-01T23:59:59.000Z

196

Sexual Assault Training in Emergency Medicine Residencies: A Survey of Program Directors  

E-Print Network (OSTI)

continue to coexist at residency training sites. In order toof SANE programs on resident training, future work should beSande et al Sexual Assault Training in Emergency Medicine

Sande, Margaret Kramer; Broderick, Kerry B.; Moreira, MD, Maria E.; Bender, Brooke; Hopkins, Emily; Buchanan, Jennie A.

2013-01-01T23:59:59.000Z

197

Energy conservation practices participant manual: For public housing residents and renters  

SciTech Connect

This training manual focuses on actions which residents can take to improve energy conservation in their homes. (BCS)

Not Available

1988-05-01T23:59:59.000Z

198

Security and Access Policy Security of and access to campus facilities, including campus residences  

E-Print Network (OSTI)

Security and Access Policy Security of and access to campus facilities, including campus residences facilities. Residence halls are secured 24 hours a day. Over extended breaks, the doors of all residence halls will be secured around the clock. Some facilities may have individual hours, which may vary

Escher, Christine

199

Short residence time coal liquefaction process including catalytic hydrogenation  

DOE Patents (OSTI)

Normally solid dissolved coal product and a distillate liquid product are produced by continuously passing a feed slurry comprising raw feed coal and a recycle solvent oil and/or slurry together with hydrogen to a preheating-reaction zone, the hydrogen pressure in the preheating-reaction zone being at least 1,500 psig (105 kg/cm[sup 2]), reacting the slurry in the preheating-reaction zone at a temperature in the range of between about 455 and about 500 C to dissolve the coal to form normally liquid coal and normally solid dissolved coal. A total slurry residence time is maintained in the reaction zone ranging from a finite value from about 0 to about 0.2 hour, and reaction effluent is continuously and directly contacted with a quenching fluid to substantially immediately reduce the temperature of the reaction effluent to below 425 C to substantially inhibit polymerization so that the yield of insoluble organic matter comprises less than 9 weight percent of said feed coal on a moisture-free basis. The reaction is performed under conditions of temperature, hydrogen pressure and residence time such that the quantity of distillate liquid boiling within the range C[sub 5]-454 C is an amount at least equal to that obtainable by performing the process under the same condition except for a longer total slurry residence time, e.g., 0.3 hour. Solvent boiling range liquid is separated from the reaction effluent and recycled as process solvent. The amount of solvent boiling range liquid is sufficient to provide at least 80 weight percent of that required to maintain the process in overall solvent balance. 6 figs.

Anderson, R.P.; Schmalzer, D.K.; Wright, C.H.

1982-05-18T23:59:59.000Z

200

ASTRO's 2007 Core Physics Curriculum for Radiation Oncology Residents  

SciTech Connect

In 2004, American Society for Therapeutic Radiology and Oncology (ASTRO) published a curriculum for physics education. The document described a 54-hour course. In 2006, the committee reconvened to update the curriculum. The committee is composed of physicists and physicians from various residency program teaching institutions. Simultaneously, members have associations with American Association of Physicists in Medicine, ASTRO, Association of Residents in Radiation Oncology, American Board of Radiology, and American College of Radiology. Representatives from the latter two organizations are key to provide feedback between the examining organizations and ASTRO. Subjects are based on Accreditation Council for Graduate Medical Education requirements (particles and hyperthermia), whereas the majority of subjects and appropriated hours/subject were developed by consensus. The new curriculum is 55 hours, containing new subjects, redistribution of subjects with updates, and reorganization of core topics. For each subject, learning objectives are provided, and for each lecture hour, a detailed outline of material to be covered is provided. Some changes include a decrease in basic radiologic physics, addition of informatics as a subject, increase in intensity-modulated radiotherapy, and migration of some brachytherapy hours to radiopharmaceuticals. The new curriculum was approved by the ASTRO board in late 2006. It is hoped that physicists will adopt the curriculum for structuring their didactic teaching program, and simultaneously, American Board of Radiology, for its written examination. American College of Radiology uses the ASTRO curriculum for their training examination topics. In addition to the curriculum, the committee added suggested references, a glossary, and a condensed version of lectures for a Postgraduate Year 2 resident physics orientation. To ensure continued commitment to a current and relevant curriculum, subject matter will be updated again in 2 years.

Klein, Eric E. [Washington University, St. Louis, MO (United States)]. E-mail: eklein@radonc.wustl.edu; Gerbi, Bruce J. [University of Minnesota, Minneapolis, MN (United States); Price, Robert A. [Fox Chase Cancer Center, Philadelphia, PA (United States); Balter, James M. [University of Michigan, Ann Arbor, MI (United States); Paliwal, Bhudatt [University of Wisconsin, Madison, WI (United States); Hughes, Lesley [Saint Joseph Medical Center, Reading, PA (United States); Huang, Eugene [MD Anderson Cancer Center, Houston, TX (United States)

2007-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Short residence time coal liquefaction process including catalytic hydrogenation  

DOE Patents (OSTI)

Normally solid dissolved coal product and a distillate liquid product are produced by continuously passing a feed slurry comprising raw feed coal and a recycle solvent oil and/or slurry together with hydrogen to a preheating-reaction zone (26, alone, or 26 together with 42), the hydrogen pressure in the preheating-reaction zone being at least 1500 psig (105 kg/cm.sup.2), reacting the slurry in the preheating-reaction zone (26, or 26 with 42) at a temperature in the range of between about 455.degree. and about 500.degree. C. to dissolve the coal to form normally liquid coal and normally solid dissolved coal. A total slurry residence time is maintained in the reaction zone ranging from a finite value from about 0 to about 0.2 hour, and reaction effluent is continuously and directly contacted with a quenching fluid (40, 68) to substantially immediately reduce the temperature of the reaction effluent to below 425.degree. C. to substantially inhibit polymerization so that the yield of insoluble organic matter comprises less than 9 weight percent of said feed coal on a moisture-free basis. The reaction is performed under conditions of temperature, hydrogen pressure and residence time such that the quantity of distillate liquid boiling within the range C.sub.5 -454.degree. C. is an amount at least equal to that obtainable by performing the process under the same condition except for a longer total slurry residence time, e.g., 0.3 hour. Solvent boiling range liquid is separated from the reaction effluent (83) and recycled as process solvent (16). The amount of solvent boiling range liquid is sufficient to provide at least 80 weight percent of that required to maintain the process in overall solvent balance.

Anderson, Raymond P. (Overland Park, KS); Schmalzer, David K. (Englewood, CO); Wright, Charles H. (Overland Park, KS)

1982-05-18T23:59:59.000Z

202

ASTRO's core physics curriculum for radiation oncology residents  

Science Conference Proceedings (OSTI)

In 2002, the Radiation Physics Committee of the American Society of Therapeutic Radiology and Oncology (ASTRO) appointed an Ad-hoc Committee on Physics Teaching to Medical Residents. The main initiative of the committee was to develop a core curriculum for physics education. Prior publications that have analyzed physics teaching have pointed to wide discrepancies among teaching programs. The committee was composed of physicists or physicians from various residency program based institutions. Simultaneously, members had associations with the American Association of Physicists in Medicine (AAPM), ASTRO, Association of Residents in Radiation Oncology (ARRO), American Board of Radiology (ABR), and the American College of Radiology (ACR). The latter two organizations' representatives were on the physics examination committees, as one of the main agendas was to provide a feedback loop between the examining organizations and ASTRO. The document resulted in a recommended 54-h course. Some of the subjects were based on American College of Graduate Medical Education (ACGME) requirements (particles, hyperthermia), whereas the majority of the subjects along with the appropriated hours per subject were devised and agreed upon by the committee. For each subject there are learning objectives and for each hour there is a detailed outline of material to be covered. Some of the required subjects/h are being taught in most institutions (i.e., Radiation Measurement and Calibration for 4 h), whereas some may be new subjects (4 h of Imaging for Radiation Oncology). The curriculum was completed and approved by the ASTRO Board in late 2003 and is slated for dissemination to the community in 2004. It is our hope that teaching physicists will adopt the recommended curriculum for their classes, and simultaneously that the ABR for its written physics examination and the ACR for its training examination will use the recommended curriculum as the basis for subject matter and depth of understanding. To ensure that the subject matter and emphasis remain current and relevant, the curriculum will be updated every 2 years.

Klein, Eric E. [Washington University, St. Louis, MO (United States)]. E-mail: klein@radonc.wustl.edu; Balter, James M. [University of Michigan, Ann Arbor, MI (United States); Chaney, Edward L. [University of North Carolina, Chapel Hill, NC (United States); Gerbi, Bruce J. [University of Minnesota, Minneapolis, MN (United States); Hughes, Lesley [Drexel University, Philadelphia, PA (United States)

2004-11-01T23:59:59.000Z

203

Solar photovoltaic systems for residences in the Northeast  

DOE Green Energy (OSTI)

Under sponsorship of the US Department of Energy, MIT Lincoln Laboratory is conducting a program to develop residential solar photovoltaic (PV) systems. The first phase of this activity involves the design, construction and testing of four prototype systems at the Northeast Residential Experiment Station. The systems employ roof-mounted photovoltaic arrays of 500 to 800 square feet which provide solar-generated electricity sufficient to cut in half the electrical demand of an energy-efficient, passive-solar residence. Construction of these systems will be complete by December 1980, and will be followed by a one-year test period.

Russell, M.C.

1980-01-01T23:59:59.000Z

204

Residence times and source ages of deep crustal fluids:  

E-Print Network (OSTI)

We present here 129 I/I and 36 Cl/Cl ratios, together with halogen concentrations in crustal fluids from the continental deep drill site (KTB-VB) in Germany, where fluids were collected from 4000 m depth during a pump test carried out in 2002 and 2003. Compared with seawater, the fluids are enriched by factors of 2, 8 and 40 for Cl) , Br and I, respectively, and show little variation over the test period. The 129 I/I ratios are between 1700 and 4100 10)15; the 36 Cl/Cl ratios are below 10 10)15. Co-variation between 129 I and 36 Cl concentrations in the fluids indicates that anthropogenic components are absent and that the ratios reflect an addition from crustal sources. The results suggest residence times of 10 Ma or more for the fluids in formations with uranium concentrations of 1 ppm. A minimum age of 30 Ma for the iodine source was derived from the correlation between 129 I and 36 Cl concentrations in the fluids. The results demonstrate that the halogen characteristics of the KTB fluids are very similar to those of other deep crustal fluids and that the combination of 129 I and 36 Cl systematics allows determination of residence times and source ages of such fluids.

Interpretation Of I; U. Fehn; G. T. Snyder

2004-01-01T23:59:59.000Z

205

Workers Remittances, Resident FCAs and Kerb Premium: A Cointegration Analysis  

E-Print Network (OSTI)

This paper employs Johansens model selection and maximum likelihood cointegration technique to analyze the relationship among workers remittances, kerb premium and resident FCAs for Pakistan during July 1993 to December 2001. The results suggest that these variables are cointegrated from July 1993 to April 1998. However, the relationship was jolted by the two-tier exchange rate regime, freezing of FCAs and subsequent tightening of foreign exchange regulations following the nuclear tests. In addition, the causal relationship is found to flow (i) from kerb premium to remittances from the Gulf and (ii) from remittances to resident FCAs prior to nuclear tests. After that, the causal relationships reverse for the Gulf and other region. The results also indicate that higher kerb premium has a detrimental effect on remittances. The findings of this paper have implications for the future economic reforms particularly in the area of the monetary, trade, exchange and payments reforms in Pakistan with special emphasis on enhancing remittances from expatriate Pakistanis. Views expressed in this working paper are those of the author and do not necessarily represent those of the State Bank of Pakistan. Comments and suggestions are welcome by the

Zulfiqar Hyder; Zulfiqar Hyder

2003-01-01T23:59:59.000Z

206

Emergency Medicine in Guyana: Lessons from Developing the Countrys First Degree-conferring Residency Program  

E-Print Network (OSTI)

emergency medicine training program at the University ofterm emergency medicine training programs in low and middle-medicine residency training program. Residency development

Forget, Nicolas Pierre; Rohde, John Paul; Rambaran, Navindranauth; Rambaran, Madan; Wright, Seth Warren

2013-01-01T23:59:59.000Z

207

International Perspective from Saudi Arabia on Procedural Skills Training During Emergency Medicine Residency: Are We Teaching the Right Things?  

E-Print Network (OSTI)

GA. Surgical residency training program. Are changes needed?of emergency residency training programs in Turkey: after 14various aspect of EM training program was presented.

Qureshi, Nadeem

2009-01-01T23:59:59.000Z

208

Can Emergency Medicine Residents Reliably Use the Internet to Answer Clinical Questions?  

E-Print Network (OSTI)

Google as a diagnostic aid: internet based study. BMJ. 2006;Engine Watch. Estimated Internet pages. Search Engine WatchResidents Reliably Use the Internet to Answer Clinical

Krause, Richard; Moscati, Ronald; Halpern, Shravanti; Schwartz, Diane G.; Abbas, June

2011-01-01T23:59:59.000Z

209

Sexual Assault Training in Emergency Medicine Residencies: A Survey of Program Directors  

E-Print Network (OSTI)

and evaluation of a training program for the management offorensic medicine training program for emergency medicinefrom approved EM residency training programs who completed a

Sande, Margaret Kramer; Broderick, Kerry B.; Moreira, MD, Maria E.; Bender, Brooke; Hopkins, Emily; Buchanan, Jennie A.

2013-01-01T23:59:59.000Z

210

Free-hand thoracic pedicle screws placed by neurosurgery residents: a CT analysis  

E-Print Network (OSTI)

in a postgraduate training program: implications forneurosurgery residency training programs. This techniqueprogram does not have routine saw-bone or cadaver training

Wang, Vincent Y.; Chin, Cynthia T.; Lu, Daniel C.; Smith, Justin S.; Chou, Dean

2010-01-01T23:59:59.000Z

211

Adaptation of the EPEC-EM Curriculum in a Residency with Asynchronous Learning  

E-Print Network (OSTI)

for a palliative care curriculum. J Pain Symptom Manage.EM to Residents EM) Curriculum. Chicago, IL: NorthwesternDE, Thomas PA, Howard DM. Curriculum Development for Medical

2010-01-01T23:59:59.000Z

212

Assessment of a Chief ComplaintBased Curriculum for Resident Education in Geriatric Emergency Medicine  

E-Print Network (OSTI)

L, et al. A geriatrics curriculum for emergency medicineA geriatric chief complaintbased curriculum derived froma practice-based curriculum analysis improved EM resident

Wadman, Michael C; Lyons, William L; Hoffman, Lance H; Muelleman, Robert L

2011-01-01T23:59:59.000Z

213

Procedural Skills Training During Emergency Medicine Residency: Are We Teaching the Right Things?  

E-Print Network (OSTI)

REFERENCES Procedural Skills Training Kilian BJ, Binder LS,perceptions of their residency training needs: results of aesearch Procedural Skills Training During Emergency Medicine

Druck, Jeffrey; Valley, Morgan A; Lowenstein, Steven R

2009-01-01T23:59:59.000Z

214

Chart Smart: A Need for Documentation and Billing Education Among Emergency Medicine Residents?  

E-Print Network (OSTI)

Adequate training in Emergency Medicine Residency?. AnnConcerns. ACEP News, Emergency Medicine Connect Career andsurvey of hospital emergency department administrators. 10.

Dawson, Brian C; Carter, Kelly; Brewer, Kori; Lawson, Luan

2010-01-01T23:59:59.000Z

215

Development of an instrument to assess residents? perceptions of equity  

E-Print Network (OSTI)

This study examined equity in the context of the allocation of park and recreation resources within a community. The contributions made by this study include: extending the original taxonomy of equity models proposed by Crompton and Wicks (1988); development of a theoretical framework for their original model; providing a current synthesis of equity based literature; advancing the Equity Implementation Model (Wicks & Crompton, 1989) by developing an instrument capable of measuring residents? perceptions and preferences of park and recreation resource allocation in their community; empirically confirming the legitimacy of alternate dimensions of equity through Structural Equation Modeling; applying information gained from using the instrument to determine the usefulness of selected variables in predicting equity preferences; and comparing data on equity preferences with those of prevailing perceptions to illustrate the utility of the instrument in guiding resource allocation decisions. Five of the original operationalizations of equity were validated (Compensatory, Taxes Paid, Direct Price, Efficiency and Advocacy). An additional operationalization, Professional Judgment, was included and also validated, while one of the original dimensions suggested by Crompton and Wicks, Equal Outcomes, could not be distinctively conceptually differentiated and so was discarded. The operationalizations of Equal Inputs and Equal Opportunity could not be differentiated to reflect distinctively different equity concepts. However, further efforts should be invested in operationalizing these two equity concepts, since they do appear to be conceptually different. Using confirmatory factor analysis, a model consisting of all seven operationalizations (Compensatory, Taxes Paid, Direct Price, Efficiency, Advocacy, Professional Judgment and Equality) was an acceptable fit and all paths were significant at the .05 level, suggesting that the proposed 23-item, seven-dimension scale, P&R-EQUITY, effectively measures seven facets of residents? perceptions of equity in the allocation of park and recreation resources. Two additional operationalizations (Demonstrated Use and Coproduction Opportunities) emerged during the research which suggested that Demonstrated Interest was inadequately operationalized, so future efforts could be focused on operationalizing those three. The scale developed in this study is intended to help officials make appropriate decisions when allocating park and recreation resources.

West, Stephanie Theresa

2004-12-01T23:59:59.000Z

216

Buildings Energy Data Book: 1.2 Building Sector Expenditures  

Buildings Energy Data Book (EERE)

8 8 2035 Buildings Energy End-Use Expenditure Splits, by Fuel Type ($2010 Billion) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity Total Percent Space Heating (3) 63.4 13.0 1.6 7.7 0.8 23.1 0.2 20.6 107.2 20.9% Water Heating 23.8 2.2 1.2 3.4 35.8 63.0 12.3% Space Cooling 0.4 55.7 56.1 10.9% Lighting 47.8 47.8 9.3% Electronics (4) 27.2 27.2 5.3% Refrigeration (5) 27.0 27.0 5.3% Computers 14.8 14.8 2.9% Cooking 5.8 0.8 0.8 5.4 12.1 2.3% Wet Clean (6) 0.9 10.4 11.3 2.2% Ventilation (7) 2.4 2.4 0.5% Other (8) 9.3 0.4 12.6 2.0 15.0 88.8 113.2 22.0% Adjust to SEDS (9) 4.6 5.3 5.3 21.7 31.6 6.2% Total 108.2 21.0 1.6 22.3 2.8 47.6 0.2 357.8 513.8 100% Note(s): Source(s): 1) Expenditures include coal and exclude wood. 2) Includes kerosene space heating ($0.8 billion) and motor gasoline other uses ($2.0 billion). 3) Includes furnace fans ($4.8 billion). 4) Includes color televisions ($14.2 billion). 5) Includes refrigerators ($24.1 billion) and freezers ($3.0

217

Buildings Energy Data Book: 1.4 Environmental Data  

Buildings Energy Data Book (EERE)

4 4 2025 Buildings Energy End-Use Carbon Dioxide Emissions Splits, by Fuel Type (Million Metric Tons) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity (3) Total Percent Space Heating (4) 263.3 35.5 6.3 15.2 2.0 59.0 6.1 98.9 427.3 19.2% Space Cooling 1.8 258.7 260.5 11.7% Lighting 245.4 245.4 11.0% Water Heating 97.7 5.7 2.5 8.3 97.6 203.7 9.2% Refrigeration (5) 129.5 129.5 5.8% Electronics (6) 122.6 122.6 5.5% Ventilation (7) 94.4 94.4 4.2% Computers 68.8 68.8 3.1% Wet Cleaning (8) 3.3 47.9 51.2 2.3% Cooking 22.7 1.6 1.6 24.3 48.7 2.2% Other (9) 25.3 0.9 21.7 3.8 26.4 366.6 418.3 18.8% Adjust to SEDS (10) 30.9 13.4 13.4 109.4 153.7 6.9% Total 445.0 55.6 6.3 41.1 5.8 108.7 6.1 100% Note(s): Source(s): 1664.0 2223.8 1) Emissions assume complete combustion from energy consumption, excluding gas flaring, coal mining, and cement production. Emissions

218

Buildings Energy Data Book: 3.3 Commercial Sector Expenditures  

Buildings Energy Data Book (EERE)

5 5 2015 Commercial Energy End-Use Expenditure Splits, by Fuel Type ($2010 Billion) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal (3) Electricity Total Percent Lighting 28.4 28.4 16.3% Space Heating 14.6 2.9 1.3 0.1 4.3 0.1 4.7 23.7 13.6% Ventilation 15.1 15.1 8.6% Space Cooling 0.3 14.2 14.5 8.3% Refrigeration 9.9 9.9 5.7% Electronics 8.8 8.8 5.1% Water Heating 4.1 0.7 0.7 2.5 7.3 4.2% Computers 5.3 5.3 3.0% Cooking 1.7 0.6 2.3 1.3% Other (4) 2.9 0.3 3.7 1.4 5.4 22.8 31.1 17.8% Adjust to SEDS (5) 5.8 4.5 4.5 17.7 28.1 16.1% Total 29.3 8.4 1.3 3.7 1.5 14.9 0.1 130.0 174.5 100% Note(s): Source(s): 1) Expenditures include coal and exclude wood. 2) Includes kerosene space heating ($0.1 billion) and motor gasoline other uses ($1.4 billion). 3) Coal average price is from AEO 2012 Early Release, all users price. 4) Includes service station equipment, ATMs, medical equipment,

219

Buildings Energy Data Book: 3.4 Commercial Environmental Emissions  

Buildings Energy Data Book (EERE)

2 2 2010 Commercial Buildings Energy End-Use Carbon Dioxide Emissions Splits, by Fuel Type (Million Metric Tons) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity (3) Total Percent Lighting 211.9 211.9 20.4% Space Heating 87.4 10.2 6.7 0.3 17.3 5.6 50.5 160.7 15.5% Space Cooling 2.3 149.1 151.3 14.6% Ventilation 95.2 95.2 9.2% Refrigeration 69.1 69.1 6.7% Electronics 46.4 46.4 4.5% Water Heating 23.2 2.0 2.0 16.2 41.4 4.0% Computers 37.7 37.7 3.6% Cooking 9.5 4.1 13.6 1.3% Other (4) 15.8 0.9 9.0 3.8 13.7 122.0 151.5 14.6% Adjust to SEDS (5) 36.2 18.4 18.4 2.8 57.3 5.5% Total 174.4 31.5 6.7 9.0 4.1 51.3 5.6 100% Note(s): Source(s): 805.0 1,036.3 1) Emissions assume complete combustion from energy consumption, excluding gas flaring, coal mining, and cement production. Emissions exclude wood since it is assumed that the carbon released from combustion is reabsorbed in a future carbon cycle. Carbon emissions

220

Buildings Energy Data Book: 2.4 Residential Environmental Data  

Buildings Energy Data Book (EERE)

4 4 2015 Residential Buildings Energy End-Use Carbon Dioxide Emissions Splits, by Fuel Type (Million Metric Tons) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity (3) Total Percent Space Heating (4) 180.5 34.9 16.6 1.8 53.3 0.6 66.6 301.0 27.4% Space Cooling 0.0 161.1 161.1 14.7% Water Heating 69.6 5.1 3.1 8.2 75.3 153.1 13.9% Lighting 83.7 83.7 7.6% Refrigeration (5) 71.7 71.7 6.5% Electronics (6) 52.0 52.0 4.7% Wet Cleaning (7) 3.2 51.6 54.7 5.0% Cooking 11.5 1.8 1.8 17.9 31.1 2.8% Computers 30.0 30.0 2.7% Other (8) 10.6 10.6 149.3 160.0 14.6% Total 264.7 40.1 32.2 1.8 74.0 0.6 100% Note(s): Source(s): 759.1 1,098.4 1) Emissions assume complete combustion from energy consumption, excluding gas flaring, coal mining, and cement production. Emissions exclude wood since it is assumed that the carbon released from combustion is reabsorbed in a future carbon cycle. 2) Includes kerosene

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Buildings Energy Data Book: 3.4 Commercial Environmental Emissions  

Buildings Energy Data Book (EERE)

5 5 2035 Commercial Buildings Energy End-Use Carbon Dioxide Emissions Splits, by Fuel Type (Million Metric Tons) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity (3) Total Percent Lighting 179.6 179.6 15.5% Space Heating 87.3 6.7 6.6 0.4 13.7 5.5 25.5 132.0 11.4% Ventilation 100.7 100.7 8.7% Space Cooling 1.7 84.1 85.8 7.4% Electronics 72.3 72.3 6.2% Refrigeration 55.6 55.6 4.8% Water Heating 28.8 2.5 2.5 13.3 44.7 3.9% Computers 33.6 33.6 2.9% Cooking 11.9 3.4 15.2 1.3% Other (4) 42.8 1.0 9.8 4.2 14.9 227.3 285.0 24.6% Adjust to SEDS (5) 21.3 13.1 13.1 120.5 154.9 13.4% Total 193.8 23.3 6.6 9.8 4.6 44.3 5.5 100% Note(s): Source(s): 915.8 1,159.3 1) Emissions assume complete combustion from energy consumption, excluding gas flaring, coal mining, and cement production. Emissions exclude wood since it is assumed that the carbon released from combustion is reabsorbed in a future carbon cycle. 2) Includes kerosene

222

Buildings Energy Data Book: 3.3 Commercial Sector Expenditures  

Buildings Energy Data Book (EERE)

4 4 2010 Commercial Energy End-Use Expenditure Splits, by Fuel Type ($2010 Billion) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal (3) Electricity Total Percent Lighting 35.4 35.4 19.7% Space Heating 15.0 2.9 0.9 0.1 3.9 0.1 8.5 27.5 15.3% Space Cooling 0.4 25.0 25.3 14.1% Ventilation 15.9 15.9 8.9% Refrigeration 11.6 11.6 6.5% Water Heating 4.0 0.6 0.6 2.7 7.3 4.1% Electronics 7.8 7.8 4.3% Computers 6.3 6.3 3.5% Cooking 1.6 0.7 2.3 1.3% Other (4) 2.7 0.3 3.3 1.2 4.8 20.4 28.0 15.6% Adjust to SEDS (5) 6.2 5.2 5.2 0.6 12.0 6.7% Total 29.9 9.0 0.9 3.3 1.3 14.5 0.1 134.8 179.4 100% Note(s): Source(s): 1) Expenditures include coal and exclude wood. 2) Includes kerosene space heating ($0.1 billion) and motor gasoline other uses ($1.2 billion). 3) Coal average price is from AEO 2012 Early Release, all users price. 4) Includes service station equipment, ATMs, medical equipment,

223

Buildings Energy Data Book: 2.4 Residential Environmental Data  

Buildings Energy Data Book (EERE)

3 3 2010 Residential Buildings Energy End-Use Carbon Dioxide Emissions Splits, by Fuel Type (Million Metric Tons) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity (3) Total Percent Space Heating (4) 185.5 38.8 18.7 2.2 59.7 0.7 77.6 323.5 26.3% Space Cooling 0.0 210.2 210.2 17.1% Water Heating 68.7 7.1 4.6 11.7 90.4 170.8 13.9% Lighting 126.0 126.0 10.2% Electronics (5) 96.5 96.5 7.8% Refrigeration (6) 80.7 80.7 6.6% Wet Cleaning (7) 2.9 57.8 60.8 4.9% Cooking 11.4 1.9 1.9 42.6 55.9 4.5% Computers 30.5 30.5 2.5% Other (8) 10.2 10.2 36.3 46.5 3.8% Adjust to SEDS (9) 30.1 30.1 2.4% Total 268.5 45.9 35.3 2.2 83.5 0.7 100% Note(s): Source(s): 878.7 1,231.4 1) Emissions assume complete combustion from energy consumption, excluding gas flaring, coal mining, and cement production. Emissions exclude wood since it is assumed that the carbon released from combustion is reabsorbed in a future carbon cycle. Carbon emissions

224

Buildings Energy Data Book: 1.2 Building Sector Expenditures  

Buildings Energy Data Book (EERE)

5 5 2010 Buildings Energy End-Use Expenditure Splits, by Fuel Type ($2010 Billion) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity Total Percent Space Heating (3) 53.7 14.2 0.9 8.0 0.6 23.7 0.1 23.2 100.8 23.4% Space Cooling 0.4 61.3 61.7 14.3% Lighting 59.3 59.3 13.8% Water Heating 18.3 2.6 2.0 4.6 17.8 40.7 9.4% Refrigeration (4) 26.9 26.9 6.2% Electronics (5) 26.1 26.1 6.1% Ventilation (6) 15.9 15.9 3.7% Cooking 4.0 0.8 0.8 8.8 13.6 3.2% Computers 12.1 12.1 2.8% Wet Cleaning (7) 0.6 11.0 11.6 2.7% Other (8) 2.7 0.3 7.7 1.2 9.2 27.3 39.2 9.1% Adjust to SEDS (9) 6.2 5.2 5.2 11.9 23.4 5.4% Total 86.0 22.3 0.9 18.5 1.8 43.5 0.1 301.6 431.2 100% Note(s): Source(s): 1) Expenditures include coal and exclude wood. 2) Includes kerosene space heating ($0.6 billion) and motor gasoline other uses ($1.2 billion). 3) Includes furnace fans ($4.5 billion). 4) Includes refrigerators ($24.1 billion) and freezers ($2.8 billion). 5) Includes color televisions ($11.0

225

Buildings Energy Data Book: 1.2 Building Sector Expenditures  

Buildings Energy Data Book (EERE)

6 6 2015 Buildings Energy End-Use Expenditure Splits, by Fuel Type ($2010 Billion) (1) Natural Gas Distil. Resid. LPG Oth(2) Total Coal Total Percent Space Heating (3) 49.5 15.9 1.3 8.1 0.7 25.9 0.2 18.7 94.3 22.7% Space Cooling 0.3 48.0 48.3 11.6% Lighting 45.9 45.9 11.0% Water Heating 17.6 2.6 1.5 4.1 18.3 40.0 9.6% Refrigeration (4) 24.9 24.9 6.0% Electronics (5) 19.8 19.8 4.7% Ventilation (6) 15.1 15.1 3.6% Computers 11.6 11.6 2.8% Wet Cleaning (7) 0.6 10.8 11.4 2.7% Cooking 3.9 0.9 0.9 4.4 9.1 2.2% Other (8) 2.9 0.3 8.9 1.4 10.6 54.1 67.6 16.3% Adjust to SEDS (9) 5.8 4.5 4.5 17.7 28.1 6.7% Total 80.6 23.3 1.3 19.4 2.1 46.1 0.2 289.3 416.2 100% Note(s): Source(s): Petroleum Electricity 1) Expenditures include coal and exclude wood. 2) Includes kerosene space heating ($0.7 billion) and motor gasoline other uses ($1.4 billion). 3) Includes furnace fans ($4.6 billion). 4) Includes refrigerators ($22.6 billion) and freezers ($2.8 billion). 5) Includes color televisions ($10.9

226

Buildings Energy Data Book: 3.4 Commercial Environmental Emissions  

Buildings Energy Data Book (EERE)

4 4 2025 Commercial Buildings Energy End-Use Carbon Dioxide Emissions Splits, by Fuel Type (Million Metric Tons) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity (3) Total Percent Lighting 171.2 171.2 16.1% Space Heating 89.4 7.7 6.3 0.4 14.3 5.5 25.7 135.0 12.7% Ventilation 94.4 94.4 8.9% Space Cooling 1.8 81.5 83.3 7.8% Electronics 63.8 63.8 6.0% Refrigeration 53.7 53.7 5.1% Computers 31.2 31.2 2.9% Water Heating 27.5 2.3 2.3 14.0 43.7 4.1% Cooking 11.0 3.5 14.5 1.4% Other (4) 25.3 0.9 9.3 3.8 14.0 177.4 216.8 20.4% Adjust to SEDS (5) 30.9 13.4 13.4 109.4 153.7 14.5% Total 185.8 24.3 6.3 9.3 4.2 44.0 5.5 100% Note(s): Source(s): 825.9 1,061.3 1) Emissions assume complete combustion from energy consumption, excluding gas flaring, coal mining, and cement production. Emissions exclude wood since it is assumed that the carbon released from combustion is reabsorbed in a future carbon cycle. 2) Includes kerosene

227

Buildings Energy Data Book: 1.4 Environmental Data  

Buildings Energy Data Book (EERE)

2 2 2010 Buildings Energy End-Use Carbon Dioxide Emissions Splits, by Fuel Type (Million Metric Tons) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity (3) Total Percent Space Heating (4) 272.9 49.0 6.7 18.7 2.6 77.0 6.2 128.2 484.3 21.3% Space Cooling 2.3 340.5 342.8 15.1% Lighting 334.1 334.1 14.7% Water Heating 91.9 9.2 4.6 13.7 98.5 204.1 9.0% Refrigeration (5) 149.8 149.8 6.6% Electronics (6) 143.0 143.0 6.3% Ventilation (7) 95.2 95.2 4.2% Computers 68.2 68.2 3.0% Wet Cleaning (8) 2.9 57.8 60.8 2.7% Cooking 20.9 1.9 1.9 36.5 59.4 2.6% Other (9) 15.8 0.9 19.1 3.8 23.9 158.4 198.1 8.7% Adjust to SEDS (10) 36.2 18.4 18.4 75.4 129.9 5.7% Total 442.9 77.5 6.7 44.3 6.4 134.8 6.2 100% Note(s): Source(s): 1685.7 2269.6 1) Emissions assume complete combustion from energy consumption, excluding gas flaring, coal mining, and cement production. Emissions

228

Buildings Energy Data Book: 1.4 Environmental Data  

Buildings Energy Data Book (EERE)

5 5 2035 Buildings Energy End-Use Carbon Dioxide Emissions Splits, by Fuel Type (Million Metric Tons) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity (3) Total Percent Space Heating (4) 257.1 29.5 6.6 14.1 1.9 52.1 6.0 102.1 417.3 17.4% Space Cooling 1.7 278.5 280.3 11.7% Lighting 253.9 253.9 10.6% Water Heating 96.0 5.1 2.1 7.3 98.1 201.4 8.4% Electronics (5) 140.4 140.4 5.9% Refrigeration (6) 137.1 137.1 5.7% Ventilation (7) 100.7 100.7 4.2% Computers 75.5 75.5 3.1% Wet Cleaning (8) 3.5 50.0 53.4 2.2% Cooking 24.1 1.5 1.5 26.5 52.2 2.2% Other (9) 42.8 1.0 23.9 4.2 29.0 456.9 528.7 22.1% Adjust to SEDS (10) 21.3 13.1 13.1 120.5 154.9 6.5% Total 446.5 48.7 6.6 41.6 6.0 103.0 6.0 100% Note(s): Source(s): 1840.3 2395.8 1) Emissions assume complete combustion from energy consumption, excluding gas flaring, coal mining, and cement production. Emissions

229

Buildings Energy Data Book: 2.4 Residential Environmental Data  

Buildings Energy Data Book (EERE)

6 6 2035 Residential Buildings Energy End-Use Carbon Dioxide Emissions Splits, by Fuel Type (Million Metric Tons) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Total Percent Space Heating (4) 169.7 22.8 14.1 1.5 38.3 0.5 76.7 285.3 23.1% Water Heating 67.2 2.6 2.1 4.7 84.8 156.7 12.7% Space Cooling 0.0 194.5 194.5 15.7% Electronics (5) 68.1 68.1 5.5% Refrigeration (6) 81.5 81.5 6.6% Lighting 74.3 74.3 6.0% Wet Cleaning (7) 3.5 50.0 53.4 4.3% Cooking 12.2 1.5 1.5 23.2 37.0 3.0% Computers 41.9 41.9 3.4% Other (8) 14.1 14.1 229.6 243.7 19.7% Total 252.7 25.4 31.9 1.5 58.7 0.5 100% Note(s): Source(s): Electricity (3) 924.5 1,236.4 1) Emissions assume complete combustion from energy consumption, excluding gas flaring, coal mining, and cement production. Emissions exclude wood since it is assumed that the carbon released from combustion is reabsorbed in a future carbon cycle. 2) Includes kerosene

230

Buildings Energy Data Book: 1.2 Building Sector Expenditures  

Buildings Energy Data Book (EERE)

7 7 2025 Buildings Energy End-Use Expenditure Splits, by Fuel Type ($2010 Billion) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity Total Percent Space Heating (3) 56.7 14.3 1.5 7.8 0.7 24.3 0.2 19.5 100.7 22.0% Space Cooling 0.3 50.5 50.9 11.1% Lighting 45.2 45.2 9.9% Water Heating 21.3 2.3 1.3 3.6 19.6 44.4 9.7% Refrigeration (4) 24.9 24.9 5.4% Electronics (5) 23.2 23.2 5.1% Computers 13.2 13.2 2.9% Wet Clean (6) 0.8 9.8 10.5 2.3% Cooking 4.8 0.8 0.8 4.9 10.5 2.3% Ventilation (7) 16.6 16.6 3.6% Other (8) 4.8 0.4 10.6 1.7 12.7 69.8 87.4 19.1% Adjust to SEDS (9) 5.9 4.9 4.9 19.2 30.0 6.6% Total 94.6 21.9 1.5 20.6 2.5 46.4 0.2 316.3 457.4 100% Note(s): Source(s): 1) Expenditures include coal and exclude wood. 2) Includes kerosene space heating ($0.7 billion) and motor gasoline other uses ($1.7 billion). 3) Includes furnace fans ($4.7 billion). 4) Includes refrigerators ($22.3 billion) and freezers ($2.6 billion). 5) Includes color televisions ($12.0

231

Buildings Energy Data Book: 1.4 Environmental Data  

Buildings Energy Data Book (EERE)

3 3 2015 Buildings Energy End-Use Carbon Dioxide Emissions Splits, by Fuel Type (Million Metric Tons) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity (3) Total Percent Space Heating (4) 270.4 43.9 6.2 16.6 2.1 68.8 6.2 93.0 438.4 21.3% Lighting 243.7 243.7 11.8% Space Cooling 1.9 241.0 242.9 11.8% Water Heating 95.0 7.2 3.1 10.3 89.6 194.9 9.4% Refrigeration (5) 127.5 127.5 6.2% Electronics (6) 101.9 101.9 4.9% Ventilation (7) 85.0 85.0 4.1% Computers 59.9 59.9 2.9% Wet Cleaning (8) 3.2 51.6 54.7 2.7% Cooking 21.7 1.8 1.8 21.4 44.9 2.2% Other (9) 17.6 0.9 19.2 3.5 23.6 277.9 319.1 15.5% Adjust to SEDS (10) 36.0 13.9 13.9 99.8 149.8 7.3% Total 445.8 65.8 6.2 40.8 5.5 118.4 6.2 100% Note(s): Source(s): 1492.5 2062.9 1) Emissions assume complete combustion from energy consumption, excluding gas flaring, coal mining, and cement production. Emissions

232

Buildings Energy Data Book: 3.3 Commercial Sector Expenditures  

Buildings Energy Data Book (EERE)

6 6 2025 Commercial Energy End-Use Expenditure Splits, by Fuel Type ($2010 Billion) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal (3) Electricity Total Percent Lighting 30.1 30.1 15.2% Space Heating 17.1 2.8 1.5 0.1 4.4 0.2 4.5 26.1 13.3% Electronics 11.2 11.2 5.7% Space Cooling 0.3 14.3 14.6 7.4% Water Heating 5.2 0.8 0.8 2.5 8.5 4.3% Computers 5.5 5.5 2.8% Refrigeration 9.4 9.4 4.8% Ventilation 16.6 16.6 8.4% Cooking 2.1 0.6 2.7 1.4% Other (4) 4.8 0.3 4.3 1.7 6.3 31.2 42.3 21.5% Adjust to SEDS (5) 5.9 4.9 4.9 19.2 30.0 15.2% Total 35.5 8.9 1.5 4.3 1.9 16.5 0.2 145.0 197.1 100% Note(s): Source(s): 1) Expenditures include coal and exclude wood. 2) Includes kerosene space heating ($0.1 billion) and motor gasoline other uses ($1.7 billion). 3) Coal average price is from AEO 2011 Early Release, all users price. 4) Includes service station equipment, ATMs, medical equipment,

233

Buildings Energy Data Book: 3.3 Commercial Sector Expenditures  

Buildings Energy Data Book (EERE)

7 7 2035 Commercial Energy End-Use Expenditure Splits, by Fuel Type ($2010 Billion) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal (3) Electricity Total Percent Lighting 32.3 32.3 14.4% Space Heating 19.0 2.7 1.6 0.2 4.5 0.2 4.6 28.2 12.5% Water Heating 6.3 1.0 1.0 18.1 25.4 11.3% Space Cooling 0.4 15.1 15.5 6.9% Electronics 13.0 13.0 5.8% Refrigeration 10.0 10.0 4.4% Computers 6.0 6.0 2.7% Cooking 2.6 0.6 3.2 1.4% Ventilation 2.4 2.4 1.1% Other (4) 9.3 0.4 4.9 2.0 7.2 40.9 57.5 25.5% Adjust to SEDS (5) 4.6 5.3 5.3 21.7 31.6 14.0% Total 42.2 9.4 1.6 4.9 2.2 18.0 0.2 164.8 225.1 100% Note(s): Source(s): 1) Expenditures include coal and exclude wood. 2) Includes kerosene space heating ($0.2 billion) and motor gasoline other uses ($2.0 billion). 3) Coal average price is from AEO 2012 Early Release, all users price. 4) Includes service station equipment, ATMs, medical equipment,

234

Buildings Energy Data Book: 3.4 Commercial Environmental Emissions  

Buildings Energy Data Book (EERE)

3 3 2015 Commercial Buildings Energy End-Use Carbon Dioxide Emissions Splits, by Fuel Type (Million Metric Tons) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity (3) Total Percent Lighting 160.0 160.0 16.6% Space Heating 89.9 9.0 6.2 0.3 15.5 5.5 26.4 137.3 14.2% Space Cooling 1.9 80.0 81.9 8.5% Ventilation 85.0 85.0 8.8% Refrigeration 55.8 55.8 5.8% Electronics 49.9 49.9 5.2% Water Heating 25.5 2.0 2.0 14.3 41.8 4.3% Computers 30.0 30.0 3.1% Cooking 10.2 3.6 13.8 1.4% Other (4) 17.6 0.9 8.6 3.5 12.9 128.6 159.2 16.5% Adjust to SEDS (5) 36.0 13.9 13.9 99.8 149.8 15.5% Total 181.2 25.8 6.2 8.6 3.8 44.4 5.5 100% Note(s): Source(s): 733.4 964.5 1) Emissions assume complete combustion from energy consumption, excluding gas flaring, coal mining, and cement production. Emissions exclude wood since it is assumed that the carbon released from combustion is reabsorbed in a future carbon cycle. 2) Includes kerosene

235

Buildings Energy Data Book: 2.4 Residential Environmental Data  

Buildings Energy Data Book (EERE)

5 5 2025 Residential Buildings Energy End-Use Carbon Dioxide Emissions Splits, by Fuel Type (Million Metric Tons) (1) Natural Petroleum Gas Distil. Resid. LPG Oth(2) Total Coal Electricity (3) Total Percent Space Heating (4) 173.9 27.9 15.2 1.6 44.7 0.6 73.2 292.3 25.1% Space Cooling 0.0 177.2 177.2 15.2% Water Heating 70.2 3.5 2.5 6.0 83.7 159.9 13.8% Lighting 74.1 74.1 6.4% Refrigeration (5) 75.8 75.8 6.5% Electronics (6) 58.7 58.7 5.1% Wet Cleaning (7) 3.3 47.9 51.2 4.4% Cooking 11.7 1.6 1.6 20.8 34.2 2.9% Computers 37.6 37.6 3.2% Other (8) 12.4 12.4 189.1 201.5 17.3% Total 259.1 31.3 31.8 1.6 64.7 0.6 100% Note(s): Source(s): 838.1 1,162.5 1) Emissions assume complete combustion from energy consumption, excluding gas flaring, coal mining, and cement production. Emissions exclude wood since it is assumed that the carbon released from combustion is reabsorbed in a future carbon cycle. 2) Includes kerosene

236

Conservation became a team sport in University of Minnesota residence halls during spring semester 2011,  

E-Print Network (OSTI)

Benefits Conservation became a team sport in University of Minnesota residence halls during spring the Conservation Madness recycling and energy reduction competition. The contest rewarded the residence hall recycling generated. The competition's goal was to encourage students to continue conserving university

Webb, Peter

237

welcome to university residences Boiler Gold Rush Check-In...........................Saturday, August 13 and  

E-Print Network (OSTI)

welcome to university residences #12;Boiler Gold Rush Check-In...........................Saturday, August 13 and Sunday, August 14, 2011 Boiler Gold Rush residence hall systems in the United States. weLcomE! 1 #12;Boiler GoLD Rush ParticiPants Your regular

Fernández-Juricic, Esteban

238

Study on structure heat capacity of high-rise residences: (part 2) comparison by insulation methods  

Science Conference Proceedings (OSTI)

This paper follows the paper of Part 1. Here we examined Air-Conditioning loads (hereinafter referred to as AC loads) impact in several deferent cases of insulation methods in interior of super high-rise residences by using the dynamic simulation software ... Keywords: AC load, heat capacity, heat insulation method, high-rise residences, simulation

Yupeng Wang; Hiroatsu Fukuda; Akihiro Mitsumoto; Akihito Ozaki; Yuko Kuma

2007-08-01T23:59:59.000Z

239

How the Recovery Act and Community Organizing Are Saving the Residents of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

How the Recovery Act and Community Organizing Are Saving the How the Recovery Act and Community Organizing Are Saving the Residents of San Mateo County Major Cash How the Recovery Act and Community Organizing Are Saving the Residents of San Mateo County Major Cash May 25, 2011 - 9:44am Addthis Steve, a resident of Hillsborough, learned about his home's energy use by receiving a comprehensive home energy assessment. Johanna Sevier Project Officer, Golden Field Office What does this project do? San Mateo County residents can get up to $4,000 per household County expects to upgrade 750 homes and reduce home energy use by an estimated 35 billion BTU's Home energy upgrade efforts expected to create 150 new jobs Obtaining a home energy upgrade is increasingly affordable in California, thanks to an array of financial incentives and rebates. In fact, residents

240

Low-energy Passive Solar Residence in Austin, Texas  

E-Print Network (OSTI)

From the various studies, it can be concluded that the excessive summer heating and the humidity are one of the major problems of the hot, humid climatic region. The literature review for this study shows that natural ventilation alone cannot meet year long optimum indoor comfort in buildings. This research, through a design exercise, intends to verify whether a naturally ventilated house, in hot humid region of Austin, TX, can enhance its passive cooling potential through double?walled wind catcher and solar chimney. In this research, a passive solar residence has been designed. Two designs have been explored on the chosen site: a basecase design without the wind catcher and solar chimney and another design with wind catcher and solar chimney. In the designcase, the placement of the wind catcher and the solar chimney has been designed so that a thermal siphon of airflow inside the building can be created. The design might show that there will be a natural airflow during the time of the year when natural wind does not flow. Moreover, the double walled wind catcher will resist the cool winter wind due to its shape and orientation. In the design, the placement of the wind catcher and the solar chimney has been done so that a thermal siphon inside the building can be created. Therefore, inside the home, there will be a natural airflow during the time of the year when natural wind does not flow. The double walled wind catcher has been designed and placed according to the orientation of the building in order to achieve the optimum wind flow throughout the year. The solar chimney has been placed in a certain part of the building where it can get maximum solar exposure. By comparing two cases, it can be clearly said that there will some kind of changed indoor comfort level. Since the potential of the design has been judged through perception, a computational fluid dynamics simulation analysis for a year is to be done.

Sau, Arunabha

2010-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Periodic review enhances LPG metering performance  

SciTech Connect

Because of the loss of experienced personnel throughout the industry, the author says one must start over teaching the basics of liquid measurement. Warren Petroleum Co., a division of Chevron U.S.A. Inc., has developed a checklist review method for its metering systems, complete with enough explanation to allow the reviewer to understand why each item is important. Simultaneously, it continues with more in-depth and theoretical training in training course. This article describes the review process.

Van Orsdol, F.G.

1988-01-25T23:59:59.000Z

242

American College of Radiology In-Training Examination for Residents in Radiation Oncology (2004-2007)  

Science Conference Proceedings (OSTI)

Purpose: To review the results of the recent American College of Radiology (ACR) in-training examinations in radiation oncology and to provide information regarding the examination changes in recent years. Methods and Materials: A retrospective review of the 2004 to 2007 ACR in-training examination was undertaken. Results: The number of residents taking the in-training examination increased from 2004 to 2007, compatible with the increase in the number of radiation oncology residents in the United States and Canada. The number of questions decreased from approximately 510 in 2004 and 2005, to 405 in 2006 and 360 in 2007, most of these changes were in the clinical oncology section. Although the in-training examination showed construct validity with resident performance improving with each year of additional clinical oncology training, it did so only until Level 3 for biology and physics. Several changes have been made to the examination process, including allowing residents to keep the examination booklet for self-study, posting of the answer key and rationales to questions on the ACR Website, and providing hard copies to residency training directors. In addition, all questions are now A type or multiple choice questions with one best answer, similar to the American Board of Radiology written examination for radiation oncology. Conclusion: Several efforts by the ACR have been made in recent years to make the examination an educational tool for radiation oncology residents and residency directors.

Paulino, Arnold C. [Department of Radiology, Division of Radiation Oncology, Baylor College of Medicine and Methodist Hospital, Houston, TX (United States)], E-mail: apaulino@tmhs.org; Kurtz, Elizabeth [Educational Services Division, American College of Radiology, Reston, VA (United States)

2008-03-01T23:59:59.000Z

243

Results of the 2004 Association of Residents in Radiation Oncology (ARRO) Survey  

Science Conference Proceedings (OSTI)

Purpose: The aim of this study was to document adequacy of training, career plans after residency, use of the in-service examination, and motivation for choice of radiation oncology as a specialty. Methods and Materials: In 2004, the Association of Residents in Radiation Oncology (ARRO) conducted a nationwide survey of all radiation oncology residents in the United States. Results: The survey was returned by 297 residents (response rate, 54%). Of the respondents, 29% were female and 71% male. The most popular career choice was joining an established private practice (38%), followed by a permanent academic career (29%). Residents for whom a permanent academic career was not their first choice were asked whether improvements in certain areas would have led them to be more likely to pursue an academic career. The most commonly chosen factors that would have had a strong or moderate influence included higher salary (81%), choice of geographic location (76%), faculty encouragement (68%), and less time commitment (68%). Of respondents in the first 3 years of training, 78% believed that they had received adequate training to proceed to the next level of training. Of those in their fourth year of training, 75% believed that they had received adequate training to enter practice. Conclusions: Multiple factors affect the educational environment of physicians in training. Data describing concerns unique to resident physicians in radiation oncology are limited. The current survey was designed to explore a variety of issues confronting radiation oncology residents. Training programs and the Residency Review Committee should consider these results when developing new policies to improve the educational experiences of residents in radiation oncology.

Patel, Shilpen [University of Maryland, Baltimore, MD (United States)]. E-mail: spatel@umm.edu; Jagsi, Reshma [Massachusetts General Hospital, Boston, MA (United States); Wilson, John [University of Pennsylvania, Philadelphia, PA (United States); Frank, Steven [University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Thakkar, Vipul V. [Cleveland Clinic, Cleveland, OH (United States); Hansen, Eric K. [University of California San Francisco, San Francisco, CA (United States)

2006-11-15T23:59:59.000Z

244

Frank Nixon Residence Pool & Spa Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Frank Nixon Residence Pool & Spa Low Temperature Geothermal Facility Frank Nixon Residence Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Frank Nixon Residence Pool & Spa Low Temperature Geothermal Facility Facility Frank Nixon Residence Sector Geothermal energy Type Pool and Spa Location Saratoga, Wyoming Coordinates 41.4549621°, -106.8064263° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

245

Cha-Ching! How One Missouri Town is Helping Residents Save Money and Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cha-Ching! How One Missouri Town is Helping Residents Save Money Cha-Ching! How One Missouri Town is Helping Residents Save Money and Energy Cha-Ching! How One Missouri Town is Helping Residents Save Money and Energy April 20, 2011 - 9:52am Addthis Workers demonstrate the nitrogen tank used to inflate tires in St. Peters, MO. | Courtesy of the City of St. Peters Workers demonstrate the nitrogen tank used to inflate tires in St. Peters, MO. | Courtesy of the City of St. Peters April Saylor April Saylor Former Digital Outreach Strategist, Office of Public Affairs Residents of St. Peters, Missouri are seeing several improvements in their community thanks to a $512,800 Energy Efficiency and Conservation Block Grant (EECBG). The grant, which is funded by the Recovery Act, has allowed the town to implement three energy efficiency programs that will save

246

Front/back/side : design of outdoor spaces for multi-family residences  

E-Print Network (OSTI)

This thesis begins with the critique of the current situation of detached, privately owned, multi-family residences and seeks alternative solutions at both the broad scale of the block, and at the scale of the spaces ...

Darden, Gwynne

1996-01-01T23:59:59.000Z

247

Storm Surge and Certain Death: Interviews with Texas Coastal Residents following Hurricane Ike  

Science Conference Proceedings (OSTI)

Hurricane Ike made landfall near Galveston, Texas, on 13 September 2008 as a large category 2 storm that generated significant storm surge and flooding. This article presents findings from an empirical case study of Texas coastal residents ...

Rebecca E. Morss; Mary H. Hayden

2010-07-01T23:59:59.000Z

248

Adaptation of the EPEC-EM Curriculum in a Residency with Asynchronous Learning  

E-Print Network (OSTI)

in Emergency Medicine (RRC-EM) have recommendations for thefor EM. As defined in the RRC-EM guidelines, emergencyEM to Residents Gisondi et al. RRC-EM requirements. Also, we

2010-01-01T23:59:59.000Z

249

The gated community: residents' crime experience and perception of safety behind gates and fences in the urban area  

E-Print Network (OSTI)

The primary purpose of the study is to explore the connections between residents' perception of safety and their crime experience, and the existence of gates and fences in multi-family housing communities in urban areas. For cultivating discussions regarding the connections between gated community territory, safety, and crime experience, this study classifies apartment communities according to the conditions of their gating and fencing: gated communities, perceived gated communities, and non-gated communities. It investigates residents' perceptions of safety and their opinions and managers' opinions on gated territory and safety. The major findings from the surveys are: Residents felt safer in gated communities than in non-gated communities. Residents' perceptions of safety in perceived gated communities were similar to those in gated communities. These results reflected the territoriality issue for improving residents' perceived safety in apartment communities. Residents' perceptions of safety in architectural spaces showed that residents' fear of crime in public and semi-public spaces must first be addressed in order to ease residents' fear of crime in an apartment territory. The reality of crime in apartment communities differed from residents' perceptions of safety. Gated community residents reported a higher crime rate than nongated community residents. In addition to gates and fences that define apartment territory, such elements as patrol services, bright lighting, direct emergency buttons, and visual access to the local police were indicated as the important factors for improving residents' perceived safety. Some architectural factors and demographic factors exhibited statistical correlations with residents' perceptions of safety. Those were types of communities, dwelling floor level, educational attainment, family size, and annual income. For predicting residents' perceptions of safety in their apartment territory, multiple regression models were obtained and residents' neighborhood attachment was also considered in the multiple regression models. The apartment community managers emphasized direct maintenance issues and residents' social contact with neighbors for improving residents' perceived safety. In conclusion, design and managerial suggestions for safer communities were proposed. For creating safer multi-family housing communities, territoriality and related architectural conditions and managerial considerations and residents' participations are emphasized. The concept of community programming for safer multi-family housing communities is suggested.

Kim, Suk Kyung

2006-08-01T23:59:59.000Z

250

Colville Resident Trout Hatchery Project Supplement Analysis (DOE/EA-0307-SA-01)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2, 2003 2, 2003 REPLY TO ATTN OF: KEC-4 SUBJECT: Colville Resident Trout Hatchery Project Supplement Analysis (DOE/EA-0307-SA-01) TO: Greg Baesler Project Manager - KEWU-4 Proposed Action: Colville Resident Trout Hatchery Project-Modifications to original proposal Project No.: 1985-038-00 Location: Colville Indian Reservation, Okanogan County, Washington Proposed by: Bonneville Power Administration (BPA) Introduction: The Bonneville Power Administration prepared an Environmental Assessment (DOE/EA-0307) for the Colville Resident Hatchery Project (Project) and published a Finding of No Significant Impact (FONSI) in the Federal Register on September 8, 1986 (Vol. 51, No.173). The Project involved the design, site selection, construction, operation and maintenance of a

251

Turbines Off NYC East River Will Provide Power to 9,500 Residents |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Turbines Off NYC East River Will Provide Power to 9,500 Residents Turbines Off NYC East River Will Provide Power to 9,500 Residents Turbines Off NYC East River Will Provide Power to 9,500 Residents February 6, 2012 - 3:16pm Addthis Free Flow System turbine being installed in East River, New York, NY (Dec 2006). | Image Credit: Kris Unger/Verdant Power, Inc. Free Flow System turbine being installed in East River, New York, NY (Dec 2006). | Image Credit: Kris Unger/Verdant Power, Inc. Hoyt Battey Water Power Market Acceleration and Deployment Team Lead, Wind and Water Power Program What does this project do? The 30 turbines will generate 1,050 kilowatts of electricity -- this power will be delivered to 9,500 New York homes. As part of the Roosevelt Island Tidal Energy project, 30 turbines are being installed along the strait that connects the Long Island Sound with the

252

Community-Minded Interns at Savannah River Site Help Area Residents in Need  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Community-Minded Interns at Savannah River Site Help Area Residents Community-Minded Interns at Savannah River Site Help Area Residents in Need with Home Repairs Community-Minded Interns at Savannah River Site Help Area Residents in Need with Home Repairs August 1, 2012 - 12:00pm Addthis James Cunningham, right, nails a board to the framework for a deck project in Jackson. Ashley Flowers, Savannah River Remediation project controls intern, assists by holding the board in place. James Cunningham, right, nails a board to the framework for a deck project in Jackson. Ashley Flowers, Savannah River Remediation project controls intern, assists by holding the board in place. AIKEN, S.C. - More than two dozen college interns who worked at the Savannah River Site (SRS) this summer joined other volunteers and headed into area neighborhoods to help people in need with home repairs.

253

Community-Minded Interns at Savannah River Site Help Area Residents in Need  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Community-Minded Interns at Savannah River Site Help Area Residents Community-Minded Interns at Savannah River Site Help Area Residents in Need with Home Repairs Community-Minded Interns at Savannah River Site Help Area Residents in Need with Home Repairs August 1, 2012 - 12:00pm Addthis James Cunningham, right, nails a board to the framework for a deck project in Jackson. Ashley Flowers, Savannah River Remediation project controls intern, assists by holding the board in place. James Cunningham, right, nails a board to the framework for a deck project in Jackson. Ashley Flowers, Savannah River Remediation project controls intern, assists by holding the board in place. AIKEN, S.C. - More than two dozen college interns who worked at the Savannah River Site (SRS) this summer joined other volunteers and headed into area neighborhoods to help people in need with home repairs.

254

Residence Time Distribution Measurement and Analysis of Pilot-Scale Pretreatment Reactors for Biofuels Production: Preprint  

SciTech Connect

Measurement and analysis of residence time distribution (RTD) data is the focus of this study where data collection methods were developed specifically for the pretreatment reactor environment. Augmented physical sampling and automated online detection methods were developed and applied. Both the measurement techniques themselves and the produced RTD data are presented and discussed.

Sievers, D.; Kuhn, E.; Tucker, M.; Stickel, J.; Wolfrum, E.

2013-06-01T23:59:59.000Z

255

A toolkit for groundwater mean residence time interpretation with gaseous tracers  

Science Conference Proceedings (OSTI)

An analytical Excel-based toolkit called Gas-Tracer-Interpretation (GTI) was developed for determining mean residence time (MRT) of groundwater samples and for validating conceptual model assumptions. This novel data interpretation toolkit improves data ... Keywords: Environmental tracer, Environmental tracers concentrations in water, Groundwater dating, Lumped-parameter modeling, Water age

Pablo Fernando Dvila, Christoph Klls, Markus Weiler

2013-12-01T23:59:59.000Z

256

Residence Time and Heat Transfer When Water Droplets Hit a Scalding Ji Yong Park*  

E-Print Network (OSTI)

1 Residence Time and Heat Transfer When Water Droplets Hit a Scalding Surface Ji Yong Park* , Chang a series of water droplets impact a smooth surface whose temperature exceeds the boiling point. The volume of the individual water droplets is 10 nL, the time between droplets is 0.3 ms, and the number of water droplets

Cahill, David G.

257

Shelter Seeking Plans of Tuscaloosa Residents for a Future Tornado Event  

Science Conference Proceedings (OSTI)

The enhanced Fujita scale category 4 (EF4) Tuscaloosa, Alabama, tornado on 27 April 2011 produced 64 fatalities along its 130-km track. Hybrid survey/interviews were conducted with a sample of 211 Tuscaloosa-area residents to determine how the 27 ...

Jason C. Senkbeil; Meganne S. Rockman; John B. Mason

2012-07-01T23:59:59.000Z

258

MILP approach in analysis of low energy building elements influence on energy savings in residences  

Science Conference Proceedings (OSTI)

Mixed Integer Linear Programming (MILP) is used for optimization of global energy system of two-family residence, located in Kragujevac, Serbia and energy, equipment and building element prices valid at Serbian and German market in year 2000. The mathematical ... Keywords: LCC, MILP, energy savings, optimization, present value

Katarina K. Pantovic

2007-08-01T23:59:59.000Z

259

Going Green? Urban vs. Rural Residency and Pro-Environmental Attitudes in China  

E-Print Network (OSTI)

With the fastest growing economy in the world, China questions the viability of their economically oriented country under increasing international pressures to strengthen environmental regulations. Understanding public policy support for environmental and economic policies requires factoring place attachment with public opinion. This research theorizes that rural residents, because of their weaker local economy, dependence on extracting natural resources, and distance from heavy pollution, will favor economic development at the expense of environmental protection. Conversely, urban residents who benefit from a stronger economy, desire more trees and parks, and have direct contact with heavy pollution and smog, will prefer an increase in environmental regulation. This study investigates the World Values Surveys (WVS), The China Survey, and other social value surveys conducted in China from 1995 to 2008, and tests urban and rural residents opinions toward the environment versus the economy. For the 2000 WVS a better measurement for urban and rural residency was created using hukou (household registration), size of town, and 2000 national census data. In support of the iv hypothesis, 2008 results show city dwellers promoting environmentalism with an equalbut- opposite rural population promoting economic development. Examining trends from 1995 to 2008 reveal two observations: first, that environmentalism is promoted consistently in all samples for urbanites; second, that trends suggest a future overtake of preference for economic development among urban and rural respondents. Such movements in attitudes could affect the direction and future of the Chinese Communist Partys economic and environmental policy reform.

Chiu, Samantha

2009-04-01T23:59:59.000Z

260

Investigation of colonias residents' potential for self-help housing construction  

E-Print Network (OSTI)

The colonias of the Lower Rio Grande Valley are rural, unincorporated subdivisions where infrastructure exists in an embryonic stage. Although many of the houses in these communities are of substandard quality, the communities provide a unique environment where self-help home building flourishes. The residents of colonias comprise a homogeneous population, predominately unskilled, Mexican-American immigrants who earn minimum wage and command little or no English language ability. Most colonias residents cannot afford housing alternatives available within the city limits, hence, the find the colonias their only alternative. This study looked at the existing conditions in the colonias and evaluated the level of potential that colonias households possessed for self-help construction. The guiding hypothesis was that colonias resident groups possess different levels of self-help housing potential. Reconnaissance pointed to types of employment as an appropriate method of grouping residents. Through the methodology of triangulation, often employed in the social sciences, the issues were probed repeatedly from multiple vantage points. The primary data was derived from a survey of key informants (social professionals working in the colonias communities) and case studies of colonias residents. Secondary data was derived from a review of germane self-help studies, particularly those from the Third World, and from studies conducted in the colonias of South Texas. After comparing data, the consistent patterns which emerged were relied upon as outcomes. The conclusions of this investigation describe the impetuses for choosing a colonia location and self-help construction, the deployment of resources in the construction effort, the builders' impressions of the self-help process, and the quality of the housing product produced through the self-help process. Once the requisite skills for self-help construction were defined, and the residents' construction potential was assessed, it was possible to suggest recommendations for methods of providing assistance. Because the findings showed that colonias residents could not be grouped according to employment, that the original hypothesis needed revision. It was found that no abilities were requisite to self-help construction; there were only those variables which facilitate or hinder the self-help construction process.

Roach, Katherine Anne

1993-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

TEXAS LPG FUEL CELL DEVELOPMENT AND DEMONSTRATION PROJECT Full-Text - Submission contains both citation data and full-text of the journal article. Full-text can be either a pre-print or post-print, but not the copyrighted article.  

Science Conference Proceedings (OSTI)

The State Energy Conservation Office has executed its first Fuel Cell Project which was awarded under a Department of Energy competitive grant process. The Texas LPG Fuel Processor Development and Fuel Cell Demonstration Program is a broad-based public/private partnership led by the Texas State Energy Conservation Office (SECO). Partners include the Alternative Fuels Research and Education Division (AFRED) of the Railroad Commission of Texas; Plug Power, Inc., Latham, NY, UOP/HyRadix, Des Plaines, IL; Southwest Research Institute (SwRI), San Antonio, TX; the Texas Natural Resource Conservation Commission (TNRCC), and the Texas Department of Transportation (TxDOT). The team proposes to mount a development and demonstration program to field-test and evaluate markets for HyRadix?s LPG fuel processor system integrated into Plug Power?s residential-scale GenSys? 5C (5 kW) PEM fuel cell system in a variety of building types and conditions of service. The program?s primary goal is to develop, test, and install a prototype propane-fueled residential fuel cell power system supplied by Plug Power and HyRadix in Texas. The propane industry is currently funding development of an optimized propane fuel processor by project partner UOP/HyRadix through its national checkoff program, the Propane Education and Research Council (PERC). Following integration and independent verification of performance by Southwest Research Institute, Plug Power and HyRadix will produce a production-ready prototype unit for use in a field demonstration. The demonstration unit produced during this task will be delivered and installed at the Texas Department of Transportation?s TransGuide headquarters in San Antonio, Texas. Simultaneously, the team will undertake a market study aimed at identifying and quantifying early-entry customers, technical and regulatory requirements, and other challenges and opportunities that need to be addressed in planning commercialization of the units. For further information please contact Mary-Jo Rowan at mary-jo.rowan@cpa.state.tx.us

SOUTHWEST RESEARCH LABORATORY SUBMITTED BY SUBCONTRACTOR, RAILROAD COMMISSION OF TEXAS

2004-07-26T23:59:59.000Z

262

Coal liquefaction process streams characterization and evaluation: The preliminary evaluation of the kinetics of coal liquefaction distillation resid conversion  

SciTech Connect

This study evaluated the use of a novel laboratory-scale batch reactor, designed by the University of Delaware, to study the kinetics of coal liquefaction resid reactivity. The short time batch reactor (STBR) is capable of conducting reactions at temperatures up to 450{degrees}C and pressures up to 2500 psi at well-defined reaction times from a few seconds to 30 min or longer. Sixty experiments were conducted with the STBR in this project. The products of the resid/tetralin/hydrogen reaction were separated by solubility, and several analytical procedures were used to evaluate the reaction products, including thermogravimetric analysis (TGA), gas chromatography (GC) and gas chromatography/mass spectrometry (GC/MS). Changes were monitored in the boiling ranges of the products, as a function of process conditions (time, temperature, and tetralin donor solvent-to-resid ratio), with and without catalysts. Two distillation resid samples were studied; Sample 1 is the resid of the second stage product stream from Wilsonville Run 259 which used Pittsburgh seam coal (Ireland mine) bituminous coal, and Sample 2 is the resid of the same streak from Wilsonville Run 260 which used Wyodak and Anderson (Black Thunder Mine) subbituminous coal. It was determined that the resid reactivity was different for the two samples studied. The results demonstrate that further development of this experimental method is warranted to empirically assess resid reactivity and to provide data for use in the construction of an empirical model of coal conversion in the direct liquefaction process.

Klein, M.T.; Calkins, W.H.; Huang, He [Delaware Univ., Newark, DE (United States). Center for Catalytic Science and Technology

1994-02-01T23:59:59.000Z

263

Medical Resident FICA Refund Claim Information The Internal Revenue Service (IRS) recently announced that it will refund the employer  

E-Print Network (OSTI)

Medical Resident FICA Refund Claim Information The Internal Revenue Service (IRS) recently announced that it will refund the employer and employee portion of FICA taxes paid for medical residents of all of our medical schools and medical centers for tax periods dating back to January 1, 1995. FICA

Russell, Lynn

264

Petition to Waive Senior Residence Unit Limitation College of Biological Sciences Dean's Office, 202 Life Sciences (530) 752-0410  

E-Print Network (OSTI)

Rev. 11/11 Petition to Waive Senior Residence Unit Limitation College of Biological Sciences Dean 45 quarter units completed by each candidate must be earned while in residence on the Davis campus Each summer session in which a student completes a course of at least 2 quarter units may be counted

Hammock, Bruce D.

265

Research on Regional Differences of Urban Resident Consumption Structure in China Based on Fuzzy Matter Element Model  

Science Conference Proceedings (OSTI)

Study of residents consumption structure plays an important role in macroeconomic policy formulation. Based on per capita annual consumption expenditure of urban households, the fuzzy matter element model is used to evaluate urban resident consumption ... Keywords: comsumption structure, fuzzy matter-element, Euclid approach degree, government consumption expenditure

Hong Li; Bo Zhou

2010-11-01T23:59:59.000Z

266

What We Talked About with the White House "Entrepreneur-in-Residence" |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

We Talked About with the White House We Talked About with the White House "Entrepreneur-in-Residence" What We Talked About with the White House "Entrepreneur-in-Residence" April 20, 2012 - 1:42pm Addthis Want more information on Apps for Energy? Signup at http://appsforenergy.challenge.gov. | Image by Hantz Leger. Want more information on Apps for Energy? Signup at http://appsforenergy.challenge.gov. | Image by Hantz Leger. Erin R. Pierce Erin R. Pierce Digital Communications Specialist, Office of Public Affairs What does this project do? Apps for Energy helps spur innovation and out-of-the-box thinking. Green Button's open data standards give developers the opportunity to impact the way millions use their utility data. Insights from developers and the general public play a key role in

267

Recommendations for 15% Above-Code Energy Efficiency Measures for Single-Family Residences  

E-Print Network (OSTI)

This paper presents an overview of the recommendations for achieving 15% above-code energy performance for single-family residences. The analysis was performed using a simulation model of an International Energy Conservation Code (IECC)- compliant, single family residence in Houston, Texas. To accomplish the 15% annual energy use reductions, twelve measures were considered, which include: tankless water heater, solar domestic hot water system, gas water heater without the standing pilot light, ducts in the conditioned space, improved duct sealing, increased air tightness, window shading and redistribution, improved window performance, improved heating and cooling system efficiency. After the total annual energy use was determined for each measure, they were then grouped to accomplish a 15% total annual energy use reduction.

Culp, C.; Haberl, J. S.; Mukhopadhyay, J.; Liu, J. B.; Yazdani, B.; Malhotra, M.

2007-12-01T23:59:59.000Z

268

Chaotic itinerancy and power-law residence time distribution in stochastic dynamical system  

E-Print Network (OSTI)

To study a chaotic itinerant motion among varieties of ordered states, we propose a stochastic model based on the mechanism of chaotic itinerancy. The model consists of a random walk on a half-line, and a Markov chain with a transition probability matrix. To investigate the stability of attractor ruins in the model, we analyze the residence time distribution of orbits at attractor ruins. We show that the residence time distribution averaged by all attractor ruins is given by the superposition of (truncated) power-law distributions, if a basin of attraction for each attractor ruin has zero measure. To make sure of this result, we carry out a computer simulation for models showing chaotic itinerancy. We also discuss the fact that chaotic itinerancy does not occur in coupled Milnor attractor systems if the transition probability among attractor ruins can be represented as a Markov chain.

Jun Namikawa

2004-10-15T23:59:59.000Z

269

Design and construction of a demonstration residence utilizing natural thermal storage  

DOE Green Energy (OSTI)

The Brookhaven House is an energy conserving residence which demonstrates how thermal mass combined with solar energy can be used to reduce heating costs in a conventional single-family house. The purpose of the project was to develop a prototypical house design that could result in immediate energy savings by being an acceptable, attractive design to developers, builders, and home buyers. Investigations were limited to only materials and methods of construction that were considered presently available and of Natural Thermal Storage design. Natural thermal storage is simply the heat storage obtained through architectural application of massive building materials integrated into the living space and structure of a residence. The research work involved analyzing many buildable configurations of thermal mass and combining their potential benefit with a variety of energy sources. It has been concluded that relatively thin mass walls of masonry directly irradiated through a multiglazed south facing aperture can significantly reduce annual heating requirements.

Jones, R.F.; Ghaffari, H.T.

1981-01-01T23:59:59.000Z

270

The American Society for Radiation Oncology's 2010 Core Physics Curriculum for Radiation Oncology Residents  

SciTech Connect

Purpose: In 2004, the American Society for Radiation Oncology (ASTRO) published its first physics education curriculum for residents, which was updated in 2007. A committee composed of physicists and physicians from various residency program teaching institutions was reconvened again to update the curriculum in 2009. Methods and Materials: Members of this committee have associations with ASTRO, the American Association of Physicists in Medicine, the Association of Residents in Radiation Oncology, the American Board of Radiology (ABR), and the American College of Radiology. Members reviewed and updated assigned subjects from the last curriculum. The updated curriculum was carefully reviewed by a representative from the ABR and other physics and clinical experts. Results: The new curriculum resulted in a recommended 56-h course, excluding initial orientation. Learning objectives are provided for each subject area, and a detailed outline of material to be covered is given for each lecture hour. Some recent changes in the curriculum include the addition of Radiation Incidents and Bioterrorism Response Training as a subject and updates that reflect new treatment techniques and modalities in a number of core subjects. The new curriculum was approved by the ASTRO board in April 2010. We anticipate that physicists will use this curriculum for structuring their teaching programs, and subsequently the ABR will adopt this educational program for its written examination. Currently, the American College of Radiology uses the ASTRO curriculum for their training examination topics. In addition to the curriculum, the committee updated suggested references and the glossary. Conclusions: The ASTRO physics education curriculum for radiation oncology residents has been updated. To ensure continued commitment to a current and relevant curriculum, the subject matter will be updated again in 2 years.

Xiao Ying, E-mail: ying.xiao@jefferson.edu [Thomas Jefferson University Hospital, Philadelphia, PA (United States); De Amorim Bernstein, Karen [Montefiore Medical Center, Bronx, NY (United States); Chetty, Indrin J. [Henry Ford Health System, Detroit, MI (United States); Eifel, Patricia [M. D. Anderson Cancer Center, Houston, TX (United States); Hughes, Lesley [Cooper University Hospital, Camden, NJ (United States); Klein, Eric E. [Washington University, Saint Louis, MO (United States); McDermott, Patrick [William Beaumont Hospital, Royal Oak, MI (United States); Prisciandaro, Joann [University of Michigan, Ann Arbor, MI (United States); Paliwal, Bhudatt [University of Wisconsin, Madison, WI (United States); Price, Robert A. [Fox Chase Cancer Center, Philadelphia, PA (United States); Werner-Wasik, Maria [Thomas Jefferson University Hospital, Philadelphia, PA (United States); Palta, Jatinder R. [University of Florida, Gainesville, FL (United States)

2011-11-15T23:59:59.000Z

271

An Analysis of Design Strategies for Climate-Controlled Residences in Selected Climates  

E-Print Network (OSTI)

This paper presents preliminary results of efforts to test the boundaries of the Givoni-Milne (G-M, 1979) bioclimatic design strategy chart, using DOE-2 simulations of a code-complaint single-story, slab-ongrade, single-family residence in selected climates. The analysis includes graphical and tabular presentations of the annual hourly simulations superimposed upon the G-M bioclimatic chart using weather data from selected climates.

Visitsak, S.; Haberl, J. S.

2004-08-01T23:59:59.000Z

272

Analysis of Energy Consumption of Duplex Residences in College Station, Texas  

E-Print Network (OSTI)

This paper characterizes the variability of energy consumption due to a series of construction, occupant, and weather-related effects in duplex residences in College Station, Texas. In this paper, spline regression was used to estimate cooling efficiency, heating efficiency, base load, modified cooling balance point temperature, and modified heating balance point temperature for monthly billed kWh against average daily outside temperature. These estimates were used to predict normalized annual consumption. Best subsets regression and multiple regression were used to explore the relationship between energy consumption and construction, occupant, and weather-related factors. The sample for this paper was I40 duplex residences which used only electricity for cooling and heating, and had one year minimum occupancy in College Station, Texas. The spline regression models with weather-related factors achieved adjusted R~ values averaging 0.82. Construction, occupant, and weather-related factors were determined to be components of energy consumption. In the final modeling, construction, occupant, and weather-related factors accounted for 93% of the variance for the normalized annual consumption of duplex residences. The findings showed there was a significant relationship between normalized annual consumption and year built, thermostat setting, cooling efficiency, heating efficiency, base load, modified cooling balance point temperature, and modified heating balance point temperature.

Kim, S. B.; Woods, P. K.

1998-01-01T23:59:59.000Z

273

Idaho Water Rental Pilot Project Probability/Coordination Study Resident Fish and Wildlife Impacts Phase III, 1997 Annual Report.  

SciTech Connect

Phase III began in 1995 with the overall goal of quantifying changes in resident fish habitat in the Snake River Basin upstream of Brownlee Reservoir resulting from the release of salmon flow augmentation water.

Leitzinger, Eric J. (Idaho Department of Fish and Game, Boise, ID)

1998-10-01T23:59:59.000Z

274

The Oceans Memory of the Atmosphere: Residence-Time and Ventilation-Rate Distributions of Water Masses  

Science Conference Proceedings (OSTI)

A conceptually new approach to diagnosing tracer-independent ventilation rates is developed. Tracer Green functions are exploited to partition ventilation rates according to the ventilated fluids residence time in the ocean interior and ...

Franois W. Primeau; Mark Holzer

2006-07-01T23:59:59.000Z

275

The Vulnerability of Mobile Home Residents in Tornado Disasters: The 2008 Super Tuesday Tornado in Macon County, Tennessee  

Science Conference Proceedings (OSTI)

Mobile home residents are known to be highly vulnerable to tornadoes and account for a considerable portion of tornado-related fatalities. The problem is partially related to the limited protection provided by the structure; however, shortcomings ...

Philip L. Chaney; Greg S. Weaver

2010-07-01T23:59:59.000Z

276

Vanadium and nickel complexes in petroleum resid acid, base, and neutral fractions  

Science Conference Proceedings (OSTI)

Acid and base fractions from petroleum vacuum resids with no detectable (by visible spectrophotometry) quantities of porphyrinic Ni or V complexes were hydrotreated under various conditions to determine if significant amounts of porphyrinic metals were released, via disassociation or other means, upon hydrotreating. No significant quantities were observed, thereby indicating that nonporphyrinic metals were not simply associated, complexed or otherwise masked (in terms of visible spectrophotometric response) porphyrinic metal complexes. However, it is possible that hydrotreating was simply not effective in breaking up these associates and/or that some porphyrinic forms of metal were in fact released but were rapidly destroyed by hydrotreating. In addition, three liquid chromatographic (LC) separation methods were sequentially applied to Cerro Negro (Orinoco belt Venezuelan heavy crude) >700[degree]C resid in an effort to separate and concentrate the metal complexes present. Nonaqueous ion exchange chromatography was used initially to separate the resid into acid, base and neutral types. Two concentrates containing 19,500 and 13,500 ppm total V, or an estimated 19 and 13 wt % V-containing compounds respectively, were obtained. The degree of enrichment of Ni compounds obtained was significantly lower. By visible spectrophotometry, using vanadyl etioporphyrin as a standard, each of the concentrates contained near a 1:1 ratio of porphyrinic:nonporphyrinic V complexes. Analogous separation behavior for porphyrinic versus nonporphyrinic metal forms was observed throughout much of the work, thereby suggesting that a comparable diversity of structures existed within each general class of metal compounds. The generally wide dispersion of both Ni and V over the LC separation scheme suggests a structural variety of metal complexes that is comparable to that observed for other heteroatoms (N, S, O) in petroleum.

Pearson, C.D.; Green, J.D.

1993-01-01T23:59:59.000Z

277

Vanadium and nickel complexes in petroleum resid acid, base, and neutral fractions  

SciTech Connect

Acid and base fractions from petroleum vacuum resids with no detectable (by visible spectrophotometry) quantities of porphyrinic Ni or V complexes were hydrotreated under various conditions to determine if significant amounts of porphyrinic metals were released, via disassociation or other means, upon hydrotreating. No significant quantities were observed, thereby indicating that nonporphyrinic metals were not simply associated, complexed or otherwise masked (in terms of visible spectrophotometric response) porphyrinic metal complexes. However, it is possible that hydrotreating was simply not effective in breaking up these associates and/or that some porphyrinic forms of metal were in fact released but were rapidly destroyed by hydrotreating. In addition, three liquid chromatographic (LC) separation methods were sequentially applied to Cerro Negro (Orinoco belt Venezuelan heavy crude) >700{degree}C resid in an effort to separate and concentrate the metal complexes present. Nonaqueous ion exchange chromatography was used initially to separate the resid into acid, base and neutral types. Two concentrates containing 19,500 and 13,500 ppm total V, or an estimated 19 and 13 wt % V-containing compounds respectively, were obtained. The degree of enrichment of Ni compounds obtained was significantly lower. By visible spectrophotometry, using vanadyl etioporphyrin as a standard, each of the concentrates contained near a 1:1 ratio of porphyrinic:nonporphyrinic V complexes. Analogous separation behavior for porphyrinic versus nonporphyrinic metal forms was observed throughout much of the work, thereby suggesting that a comparable diversity of structures existed within each general class of metal compounds. The generally wide dispersion of both Ni and V over the LC separation scheme suggests a structural variety of metal complexes that is comparable to that observed for other heteroatoms (N, S, O) in petroleum.

Pearson, C.D.; Green, J.D.

1993-01-01T23:59:59.000Z

278

Review of BPA Funded Sturgeon, Resident Fish and Wildlife Projects for 1990/1991.  

DOE Green Energy (OSTI)

The Bonneville Power Administration (BPA) held a public meeting on November 19--21, 1991, for the purpose of review, coordination, and consultation of the BPA-funded projects for sturgeon, resident fish, and wildlife in the Columbia River Basin (Basin). The comments received after the meeting were favorable and the participants agreed that the meeting was stimulating and productive. The information exchanged should lead to better coordination with other projects throughout the Basin. This document list the projects by title, the project leaders and BPA's project officers, and an abstract of each leader's presentation.

United States. Bonneville Power Administration.

1990-12-01T23:59:59.000Z

279

Analysis Of Residence Time Distribution Of Fluid Flow By Axial Dispersion Model  

Science Conference Proceedings (OSTI)

Radioactive tracer {sup 82}Br in the form of KBr-82 with activity {+-} 1 mCi has been injected into steel pipeline to qualify the extent dispersion of water flowing inside it. Internal diameter of the pipe is 3 in. The water source was originated from water tank through which the water flow gravitically into the pipeline. Two collimated sodium iodide detectors were used in this experiment each of which was placed on the top of the pipeline at the distance of 8 and 11 m from injection point respectively. Residence time distribution (RTD) curves obtained from injection of tracer are elaborated numerically to find information of the fluid flow properties. The transit time of tracer calculated from the mean residence time (MRT) of each RTD curves is 14.9 s, therefore the flow velocity of the water is 0.2 m/s. The dispersion number, D/uL, for each RTD curve estimated by using axial dispersion model are 0.055 and 0.06 respectively. These calculations are performed after fitting the simulated axial dispersion model on the experiment curves. These results indicated that the extent of dispersion of water flowing in the pipeline is in the category of intermediate.

Sugiharto [Department of Physics, Faculty of Mathematics and Natural Sciences, Bandung Institute of Technology, Jl. Ganesha 10, Bandung 40132 (Indonesia); Centre for Applications of Isotopes and Radiation Technology-National Nuclear Energy Agency, Jl. Lebak Bulus Raya No. 49, Jakarta 12440 (Indonesia); Su'ud, Zaki; Kurniadi, Rizal; Waris, Abdul [Centre for Applications of Isotopes and Radiation Technology-National Nuclear Energy Agency, Jl. Lebak Bulus Raya No. 49, Jakarta 12440 (Indonesia); Abidin, Zainal [Department of Physics, Faculty of Mathematics and Natural Sciences, Bandung Institute of Technology, Jl. Ganesha 10, Bandung 40132 (Indonesia)

2010-12-23T23:59:59.000Z

280

Microsoft PowerPoint - SRS Headcount by County of Residence Q4 FY 2013.pptx  

NLE Websites -- All DOE Office Websites (Extended Search)

GA County SRNS SRR WSI *Parsons GA County SRNS SRR WSI *Parsons Amer- esco MOX DOE-SR GA County Total Burke 23 15 4 17 0 24 0 83 Columbia 719 258 101 75 6 148 44 1351 Jefferson 2 3 0 1 0 3 0 9 Lincoln 11 1 2 1 0 4 0 19 McDuffie 10 8 0 5 0 13 2 38 Richmond 508 184 110 117 2 215 34 1170 Screven 20 7 1 6 0 4 0 38 Other 24 12 3 91 0 162 0 292 Total 1317 488 221 313 * 8 573 80 3000 SRS Employee Headcount by County of Residence Q4, FY 13

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Hodges residence: performance of a direct gain passive solar home in Iowa  

DOE Green Energy (OSTI)

Results are presented for the performance of the Hodges Residence, a 2200-square-foot earth-sheltered direct gain passive solar home in Ames, Iowa, during the 1979-80 heating season, its first occupied season. No night insulation was used on its 500 square feet of double-pane glass. Total auxiliary heat required was 43 GJ (41 MBTU) gross and 26 GJ (25 MBTU) net, amounting, respectively, to 60 and 36 kJ/C/sup 0/-day-m/sup 2/ (2.9 and 1.8 BTU/F/sup 0/-day-ft/sup 2/). The heating season was unusually cloudy and included the cloudiest January in the 21 years of Ames insolation measurements. Results are also presented for the performance of the hollow-core floor which serves as the main storage mass and for the comfort range in the house.

Hodges, L.

1980-01-01T23:59:59.000Z

282

Review of BPA Funded Sturgeon, Resident Fish and Wildlife Projects, 1989/1990.  

DOE Green Energy (OSTI)

The Bonneville Power Administration (BPA) held a public meeting on November 6-7, 1990, for the purpose of review, coordination, and consultation of the BPA-funded projects for sturgeon, resident fish, and wildlife in the Columbia River Basin (Basin). The comments received after the meeting were favorable and the participants agreed that the meeting was stimulating and productive. The information exchanged should lead to better coordination with other projects throughout the Basin. The following pages list the projects by title, the project leaders and BPA's project officers, and an abstract of each leaders presentation. These summaries are in some cases preliminary; they are subject to change and should not be quoted without consulting the project leader.

United States. Bonneville Power Administration.

1990-12-01T23:59:59.000Z

283

Short-Term Monitoring to Diagnose Comfort Problems in a Residence in Central Texas  

E-Print Network (OSTI)

This paper presents results from a project to resolve comfort problems created by high indoor humidity in a 3,400 sq.ft. house in Bryan, Texas. The case study house had been certified by the local utility to meet their energy efficiency standards. However, the resident of the house complained that the house felt too humid although the desired temperature conditions were being maintained. Several HVAC contractors had been previously hired to resolve the problem without success. The field measurements undertaken to diagnose the problem are typical of those that could be undertaken by a house inspector and include an inspection of the construction of the house, short-term monitoring of temperature and humidity, blower door tests and whole-house pressurization tests. To perform the analysis both floors of the house were instrumented with portable data loggers and monitored for a period of two weeks to measure the temperature and relative humidity of the supply, return and ambient conditions. Analysis procedures applied to the house include comparing the measured data against the ASHRAE comfort zone (ASHRAE, 1997) which confirmed adequate zone temperatures with high humidity conditions, and inadequate supply air delivery temperatures for humidity removal. Combined results of the blower door tests and whole-house pressurization tests indicated a potential for leakage through the return air duct. After the recommendations were presented to the homeowner, a new contractor was hired and retrofits applied on the house (i.e., cleaning the cooling coils, enlarging the compressor and relining of the return duct). Measurements were then repeated to determine that the problem had been f ~ e d . This paper describes the case study residence, the measurements used to diagnose the problem, analysis methods, and presents results of the application of the analysis.

Kootin-Sanwu, V.; Sresthaputra, A.; Haberl, J. S.

2000-01-01T23:59:59.000Z

284

Simulations of the energy performance of a solar photovoltaic residence and hybrid electric automobile in Fresno, California  

Science Conference Proceedings (OSTI)

The hour-by-hour energy performance of a photovoltaic residence and hybrid electric vehicle system that could be built with 1980s' technology is analyzed. Thermal and electrical performance in both stand-alone and grid-connected configurations were simulated with computer models using actual hourly solar and weather data for Fresno, California. The system centers around an energy-efficient residence that incorporates passive heating and cooling. For the simulations in this study, 110 square meters of GE photovoltaic shingle modules (9.6 kW(e) rated power), a 10 kW(e) dc-ac inverter, and advanced lead-acid batteries of 61 kWh(e) capacity were added to the residence. The auto has 30 kWh(e) of lead-acid batteries and a 40-hp electric drive motor for propulsion. The auto was assumed to travel 100 km (62 miles) each day (36,500 km (22,680 miles) annually). A small (10 kW(e)) backup liquid-fueled engine/generator in the auto provides supplemental electricity on cloudy days and for long-distance travel. The utility would provide backup electricity for the residence, or the auto engine/generator can provide this backup power to the residence as well as so-called waste heat from the engine for space heating and domestic hot water. Year-round heating and cooling needs are met primarily with passive design features, and most hot water comes from a solar water heater. The PV array meets all the electrical loads of the residence on 315 days and part of the load on the other 50 days. The PV array also meets the entire auto electricity load on 166 days, and part of the load on another 116 days. A brief cost analysis indicates that both stand-alone and grid-connected systems would be competitive with grid electricity and conventional autos within this decade.

Reuyl, J.S.; Schutt, R.D.

1982-01-01T23:59:59.000Z

285

Magnetic field exposure assessment for adult residents of Maine who live near and far away from overhead transmission lines  

Science Conference Proceedings (OSTI)

Sixty-Hz magnetic field exposures were measured for 45 adult residents of Maine. Thirty of the subjects resided near rights-of-way (ROWs) with either 345- and 115-kV transmission lines, or ROWs with only 115-kV transmission lines; fifteen resided far from any transmission lines. Personal exposure data for a single 24-hour period was acquired with the EMDEX. The EMDEX's event-marker button was used to partition exposures into Home and Away components. Also, three area measurements were taken for each subject during the personal exposure measurement period: (1) 24-hr fixed-site bedroom measurement with a second EMDEX; (2) Spot measurements in at least three rooms of every residence; and (3) Spot measurements outside each residence. Residence near transmission lines highly loaded during the measurement period was associated with increased Home and Total exposure relative to a far-away population. Average exposure level while away from home was uniform (at about 2 mG) throughout the study population. On a quantitative level, Home exposure was correlated equivalently with Spot-In (r = .70) and the 24-hr fixed site measurement (r = .68). Correlations of area measurements with Total exposure were weaker because of the dilution effect of Away exposure (r = .64 for Spot-In; r = .61 for 24-h Bedroom). Away and Home exposures were not correlated (r = .14), which reinforced our confidence that the participants used the EMDEX correctly. The data suggest the need for caution before inferences are drawn about total personal exposure from area measurements. The study demonstrates the feasibility of obtaining valid measures of magnetic-field exposure with the personal exposure monitors that have been developed.

Kavet, R.; Silva, J.M.; Thornton, D. (Enertech Consultants, Campbell, CA (United States))

1992-01-01T23:59:59.000Z

286

Commissioning Tools for Heating/Cooling System in Residence - Verification of Floor Heating System and Room Air Conditioning System Performance  

E-Print Network (OSTI)

Tools of evaluating the performance of floor heating and room air conditioner are examined as a commissioning tool. Simple method is needed to check these performance while in use by residents, because evaluation currently requires significant time and effort. Therefore, this paper proposes a) two methods of evaluating the floor heating efficiency from the room / crawl space temperature and the energy consumption and b) method of evaluating COP of the room air conditioner from the data measured at the external unit. Case studies in which these tools were applied to actual residences are presented to demonstrate their effectiveness.

Miura, H.; Hokoi, S.; Iwamae, A.; Umeno, T.; Kondo, S.

2004-01-01T23:59:59.000Z

287

Annual Report on Resident Fish Activities, 1986 Fiscal Year, Columbia River Basin Fish and Wildlife Program, Action Item 41.8.  

Science Conference Proceedings (OSTI)

This report addresses the status of resident fish projects currently funded by the Bonneville Power Administration (BPA) under the Columbia River Basin Fish and Wildlife Program (Program) established pursuant to the Northwest Power Act (P.L. 96-501). The report provides a brief synopsis, review and discussion of 13 resident fish projects funded during September 1985 to May 1986. The resident fish section of the Program addresses measures which are intended to protect resident fish, mitigate fishery losses caused by hydroelectric projects, and compensate for past losses through enhancement measures. These measures include, but are not limited to: flow requirements, drawdown requirements, temperature control, and streambed protection.

United States. Bonneville Power Administration.

1986-05-01T23:59:59.000Z

288

Phase I Water Rental Pilot Project : Snake River Resident Fish and Wildlife Resources and Management Recommendations.  

DOE Green Energy (OSTI)

The Idaho Water Rental Pilot Project was implemented as a part of the Non-Treaty Storage Fish and Wildlife Agreement (NTSA) between Bonneville Power Administration and the Columbia Basin Fish and Wildlife Authority. The goal of the project is to improve juvenile and adult salmon and steelhead passage in the lower Snake River with the use of rented water for flow augmentation. The primary purpose of this project is to summarize existing resource information and provide recommendations to protect or enhance resident fish and wildlife resources in Idaho with actions achieving flow augmentation for anadromous fish. Potential impacts of an annual flow augmentation program on Idaho reservoirs and streams are modeled. Potential sources of water for flow augmentation and operational or institutional constraints to the use of that water are identified. This report does not advocate flow augmentation as the preferred long-term recovery action for salmon. The state of Idaho strongly believes that annual drawdown of the four lower Snake reservoirs is critical to the long-term enhancement and recovery of salmon (Andrus 1990). Existing water level management includes balancing the needs of hydropower production, irrigated agriculture, municipalities and industries with fish, wildlife and recreation. Reservoir minimum pool maintenance, water quality and instream flows are issues of public concern that will be directly affected by the timing and quantity of water rental releases for salmon flow augmentation, The potential of renting water from Idaho rental pools for salmon flow augmentation is complicated by institutional impediments, competition from other water users, and dry year shortages. Water rental will contribute to a reduction in carryover storage in a series of dry years when salmon flow augmentation is most critical. Such a reduction in carryover can have negative impacts on reservoir fisheries by eliminating shoreline spawning beds, reducing available fish habitat, and exacerbating adverse water quality conditions. A reduction in carry over can lead to seasonal reductions in instream flows, which may also negatively affect fish, wildlife, and recreation in Idaho. The Idaho Water Rental Pilot Project does provide opportunities to protect and enhance resident fish and wildlife habitat by improving water quality and instream flows. Control of point sources, such as sewage and industrial discharges, alone will not achieve water quality goals in Idaho reservoirs and streams. Slow, continuous releases of rented water can increase and stabilize instream flows, increase available fish and wildlife habitat, decrease fish displacement, and improve water quality. Island integrity, requisite for waterfowl protection from mainland predators, can be maintained with improved timing of water releases. Rebuilding Snake River salmon and steelhead runs requires a cooperative commitment and increased flexibility in system operations to increase flow velocities for fish passage and migration. Idaho's resident fish and wildlife resources require judicious management and a willingness by all parties to liberate water supplies equitably.

Riggin, Stacey H.; Hansen, H. Jerome

1992-10-01T23:59:59.000Z

289

The Relationship between Drop In-Cloud Residence Time and Drizzle Production in Numerically Simulated Stratocumulus Clouds  

Science Conference Proceedings (OSTI)

This paper considers the production of drizzle in statocumulus clouds in relation to the boundary-layer turbulent kinetic energy and in-cloud residence times. It is shown that drizzle production in statocumulus of the order of 400 m in depth is ...

Graham Feingold; W. R. Cotton; Bjorn Stevens; A. S. Frisch

1996-04-01T23:59:59.000Z

290

Planning and decision making about the future care of older group home residents and transition to residential  

E-Print Network (OSTI)

to residential aged carejir_1297 1..13 C. Bigby,1 B. Bowers2 & R. Webber3 1 School of SocialWork and Social residents and the decisions made that a move to residential aged care was necessary. Methods Grounded to a residential aged care facility was neces- sary were made in haste and seen as a fait accompli to involved

Wisconsin at Madison, University of

291

www.eia.gov  

U.S. Energy Information Administration (EIA)

Natural Gas Nonfuel Products from Refineries Coal and Coal Coke Fuel Oil and LPG Resid ... Wood-Related and Paper-Related Refuse Net Steam/Hot Water Miscellaneous

292

Waste Heat Powered Ammonia Absorption Refrigeration Unit for LPG Recovery  

SciTech Connect

An emerging DOE-sponsored technology has been deployed. The technology recovers light ends from a catalytic reformer plant using waste heat powered ammonia absorption refrigeration. It is deployed at the 17,000 bpd Bloomfield, New Mexico refinery of Western Refining Company. The technology recovers approximately 50,000 barrels per year of liquefied petroleum gas that was formerly being flared. The elimination of the flare also reduces CO2 emissions by 17,000 tons per year, plus tons per year reductions in NOx, CO, and VOCs. The waste heat is supplied directly to the absorption unit from the Unifiner effluent. The added cooling of that stream relieves a bottleneck formerly present due to restricted availability of cooling water. The 350oF Unifiner effluent is cooled to 260oF. The catalytic reformer vent gas is directly chilled to minus 25oF, and the FCC column overhead reflux is chilled by 25oF glycol. Notwithstanding a substantial cost overrun and schedule slippage, this project can now be considered a success: it is both profitable and highly beneficial to the environment. The capabilities of directly-integrated waste-heat powered ammonia absorption refrigeration and their benefits to the refining industry have been demonstrated.

Donald C, Energy Concepts Co.; Lauber, Eric, Western Refining Co.

2008-06-20T23:59:59.000Z

293

"Table A2. Total Consumption of LPG, Distillate Fuel Oil,...  

U.S. Energy Information Administration (EIA) Indexed Site

,32,1688,378,0,58,0,15.7 3274," Lime","Q",657,"W","Q",657,"W",0,0,0,33.9 3296," Mineral Wool","W","W","W",113,34,"W","W","W",0,2 33,"Primary Metal Industries","W",5117,"W",2433,494...

294

Numerical Simulations of Leakage from Underground LPG Storage Caverns  

E-Print Network (OSTI)

Petroleum gases, such as propane and butane, are liquefiedIn this study, we focused on propane (C 3 H 8 ) as the mostis capable of treating propane in the same way as other

Yamamoto, Hajime; Pruess, Karsten

2004-01-01T23:59:59.000Z

295

Head-and-Neck Target Delineation Among Radiation Oncology Residents After a Teaching Intervention: A Prospective, Blinded Pilot Study  

Science Conference Proceedings (OSTI)

Purpose: We conducted this study to determine the feasibility of incorporating a teaching intervention on target delineation into the educational curriculum of a radiation oncology residency program and to assess the short-term effects on resident skills. Methods and Materials: The study schema consisted of a baseline evaluation, the teaching intervention, and a follow-up evaluation. At the baseline evaluation, the participants contoured three clinical tumor volumes (CTVs) (70 Gy, 59.4 Gy, and 54 Gy) on six contrast-enhanced axial computed tomography images of a de-identified patient with Stage T2N2bM0 squamous cell carcinoma of the right base of the tongue. The participants attended a series of head-and-neck oncology and anatomy seminars. The teaching intervention consisted of a didactic lecture and an interactive hands-on practical session designed to improve the knowledge and skills for target delineation in the head and neck. At the follow-up evaluation, the residents again contoured the CTVs. Results: Of the 14 eligible residents, 11 (79%) actually participated in the study. For all participants, but especially for those who had not had previous experience with head-and-neck target delineation, the teaching intervention was associated with improvement in the delineation of the node-negative neck (CTV 54 Gy contour). Regardless of clinical experience, participants had difficulty determining what should be included in the CTV 59.4 Gy contour to ensure adequate coverage of potential microscopic disease. Conclusion: Incorporating a teaching intervention into the education curriculum of a radiation oncology residency program is feasible and was associated with short-term improvements in target delineation skills. Subsequent interventions will require content refinement, additional validation, longer term follow-up, and multi-institutional collaboration.

Bekelman, Justin E. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)], E-mail: bekelmaj@mskcc.org; Wolden, Suzanne; Lee, Nancy [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

2009-02-01T23:59:59.000Z

296

Energy Savings Resulting from Shading Devices on Single-Family Residences in Austin, Texas  

E-Print Network (OSTI)

Potential annual energy savings resulting from window shading devices on three prototypical Austin, Texas, single-family residences were computed in this study. Savings were calculated for interior (shades, blinds, draperies, window film, and tinted windows) and exterior (solar screens, awnings, overhangs, and the effects of recessed windows and vegetation) shading devices. The analysis was conducted with the DOE-2 building energy analysis computer program. Nominal baseline cases (single glazing, gas heating, and nominal shading from eaves and neighboring buildings) were run for each prototype. Selected baseline variants (double glazing, all electric, and no eaves or neighbor shading) were run to test parameter sensitivity. Results are reported in terms of the annual heating and cooling energy use and energy cost, with each device in place, as compared to the baseline cases. The devices are ranked in term of energy savings and energy coat savings. Another significant result is the multiple-regression correlation of annual heating and cooling energy savings with Shading Coefficient and U-value that generalizes the performance of the shading devices.

Pletzer, R. K.; Jones, J. W.; Hunn, B. D.

1987-01-01T23:59:59.000Z

297

Estimates of achievable potential for electricity efficiency improvements in U.S. residences  

SciTech Connect

This paper investigates the potential for public policies to achieve electricity efficiency improvements in US residences. This estimate of achievable potential builds upon a database of energy-efficient technologies developed for a previous study estimating the technical potential for electricity savings. The savings potential and cost for each efficiency measure in the database is modified to reflect the expected results of policies implemented between 1990 and 2010. Factors included in these modifications are: the market penetration of efficiency measures, the costs of administering policies, and adjustments to the technical potential measures to reflect the actual energy savings and cost experienced in the past. When all adjustment factors are considered, this study estimates that policies can achieve approximately 45% of the technical potential savings during the period from 1990 to 2010. Thus, policies can potentially avoid 18% of the annual frozen-efficiency baseline electricity consumption forecast for the year 2010. This study also investigates the uncertainty in best estimate of achievable potential by estimating two alternative scenarios -- a

Brown, Richard

1993-05-01T23:59:59.000Z

298

Early Detection of Melanoma and other Cancers in Residents of Nevada  

SciTech Connect

The overall goal of this project was to develop simple and inexpensive tests to screen for the presence of early stage cancer in the residents of Nevada with a particular emphasis on the membership of the Hotel Employee Restaurant Employee International Union (HEREIU) in Las Vegas. Our specific goals were: 1) to develop a clinical database of individuals with cancer and to create a biological specimen Collection and Storage Systems (the NVCI bio-bank); 2) to initiate screening of individuals for proteomic markers indicating susceptibility to or the presence of specific cancers, e.g. breast, ovarian, prostate and bladder. In addition, we proposed the implementation of novel digital imaging technologies to detect melanoma; 3) to genotype blood samples from individuals who consent to participate in IRB approved research studies using a high throughput single nucleotide polymorphisms (SNP) method based on optical thin-film biosensor chip technology; and 4) to conduct biostatistical analysis of clinical, demographic, genetic, proteomic and digital imaging data to stratify the population cohort into relative risk groups for cancers that are prevalent in Nevada.

David Ward, PhD and Nicholas Vogelzang, MD

2006-10-30T23:59:59.000Z

299

Design of a photovoltaic system for a Southeast all-electric residence  

Science Conference Proceedings (OSTI)

A photovoltaic system has been developed and integrated into a single-story residence suitable for the Southeast region of the country. The design addresses an integral mounted array which displaces conventional roof sheathing, roofing felt and shingles. The array has a rated power output of 5.6 kW at NOCT conditions and covers 86 sq.m. of roof area. A 6 kW utility-tied inverter is used in the power conversion subsystem, representative of a lower cost version, currently available hardware. The system provides feedback of excess energy to the utility, which is the most promising feedback of excess energy to the utility, which is the most promising approach for grid-connected systems in the mid-1980's. The complete system and house design are described, including all the pertinent installation and construction drawings. Specific performance results are presented for the Miami, Florida, and Charleston, SC, regions. The system presented, coupled with previously completed designs, provide a set of design options expected to be available to residential homeowners in the mid-1980's.

Mehalick, E.M.; Tully, G.F.; Johnson, J.; Truncellito, N.; Schaeffer, R.; Parker, J.

1982-01-01T23:59:59.000Z

300

Effects of residence time distribution and packing on methanol oxidation in biotrickling filter  

SciTech Connect

The effects of residence time distribution (RTD) on biotrickling filter systems and the comparison of the maximum elimination capacity (EC) and poisoning limits as functions of loadings of two packing media, Celite Biocatalyst Carrier R-635 and a subbituminous coal (Hat Creek coal from British Columbia), were studied. To alter the RTD patterns in the two reactor columns, two baffle designs were chosen. The RTD tests were done under dry conditions, over a range of airflow rates, with zero baffle, one baffle, and two baffles added into each column. Mixed culture from compost was used to acclimate the bed for the methanol removal efficiency study. No nutrients were added in the coal column. To study the poisoning limit, the inlet methanol concentration was randomly increased until a severe drop in removal efficiency occurred. From the RTD tests and the removal efficiency runs, which did not result in 100% conversion, number of tank-in-series (N) values, maximum EC values, and rate constants of each column with different baffle configurations could be obtained. Results from duplicate runs showed that addition of baffles decreased the N values of the columns and increased the back mixing in both systems. Maximum EC values, critical loadings, and poisoning limits also increased with increasing back mixing. Coal was superior to Celite Biocatalyst Carrier R-635 because it gave good conversions without additional nutrients. In all runs, the rate of methanol removal was controlled by a zero order process. 14 refs., 10 figs., 7 tabs.

Yuanita W. Hutomo; K.L. Pinder [University of British Columbia, Vancouver, BC (Canada). Chemical and Biological Engineering Department

2006-03-15T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Localization of Southern Resident Killer Whales Using Two Star Arrays to Support Marine Renewable Energy  

Science Conference Proceedings (OSTI)

Tidal power has been identified as one of the most potential commercial-scale renewable energy sources. Puget Sound, Washington, is a potential site to deploy tidal power generating devices. The risk of injury for killer whales needs to be managed before the deployment of these types of devices can be approved by regulating authorities. A passive acoustic system consisting of two star arrays, each with four hydrophones, was designed and implemented for the detection and localization of Southern Resident killer whales. Deployment of the passive acoustic system was conducted at Sequim Bay, Washington. A total of nine test locations were chosen, within a radius of 250 m around the star arrays, to test our localization approach. For the localization algorithm, a least square solver was applied to obtain a bearing location from each star array. The final source location was determined by the intersection of the bearings given by each of the two star arrays. Bearing and distance errors were obtained to conduct comparison between the calculated and true (from Global Positioning System) locations. The results indicated that bearing errors were within 1.04 for eight of the test locations; one location had bearing errors slightly larger than expected due to the strong background noise at that position. For the distance errors, six of the test locations were within the range of 1.91 to 32.36 m. The other two test locations were near the intersection line between the centers of the two star arrays, which were expected to have large errors from the theoretical sensitivity analysis performed.

Ren, Huiying; Deng, Zhiqun; Carlson, Thomas J.; Sun, Yannan; Fu, Tao; Martinez, Jayson J.; Matzner, Shari; Myers, Joshua R.

2012-10-19T23:59:59.000Z

302

Target Strength of Southern Resident Killer Whales (Orcinus orca): Measurement and Modeling  

SciTech Connect

A major criterion for tidal power licensing in Washingtons Puget Sound is the management of the risk of injury to killer whales due to collision with moving turbine blades. An active monitoring system is being proposed for killer whale detection, tracking, and alerting that links to and triggers temporary turbine shutdown when there is risk of collision. Target strength (TS) modeling of the killer whale is critical to the design and application of any active monitoring system. A 1996 study performed a high-resolution measurement of acoustic reflectivity as a function of frequency of a female bottlenose dolphin (2.2 m length) at broadside aspect and TS as a function of incident angle at 67 kHz frequency. Assuming that killer whales share similar morphology structure with the bottlenose dolphin, we extrapolated the TS of an adult killer whale 7.5 m in length at 67 kHz frequency with -8 dB at broadside aspect and -28 dB at tail side. The backscattering data from three Southern Resident killer whales were analyzed to obtain the TS measurement. These data were collected at Lime Kiln State Park using a split-beam system deployed from a boat. The TS of the killer whale at higher frequency (200 kHz) was estimated based on a three-layer model for plane wave reflection from the lung of the whale. The TS data of killer whales were in good agreement with our model. In this paper, we also discuss and explain possible causes for measurement estimation error.

Xu, Jinshan; Deng, Zhiqun; Carlson, Thomas J.; Moore, Brian

2012-04-04T23:59:59.000Z

303

Results of the Association of Directors of Radiation Oncology Programs (ADROP) Survey of Radiation Oncology Residency Program Directors  

Science Conference Proceedings (OSTI)

Purpose: To survey the radiation oncology residency program directors on the topics of departmental and institutional support systems, residency program structure, Accreditation Council for Graduate Medical Education (ACGME) requirements, and challenges as program director. Methods: A survey was developed and distributed by the leadership of the Association of Directors of Radiation Oncology Programs to all radiation oncology program directors. Summary statistics, medians, and ranges were collated from responses. Results: Radiation oncology program directors had implemented all current required aspects of the ACGME Outcome Project into their training curriculum. Didactic curricula were similar across programs nationally, but research requirements and resources varied widely. Program directors responded that implementation of the ACGME Outcome Project and the external review process were among their greatest challenges. Protected time was the top priority for program directors. Conclusions: The Association of Directors of Radiation Oncology Programs recommends that all radiation oncology program directors have protected time and an administrative stipend to support their important administrative and educational role. Departments and institutions should provide adequate and equitable resources to the program directors and residents to meet increasingly demanding training program requirements.

Harris, Eleanor [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States)], E-mail: Eleanor.Harris@moffitt.org; Abdel-Wahab, May [Department of Radiation Oncology, University of Miami, Miami, FL (United States); Spangler, Ann E. [Moncrief Radiation Oncology Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Lawton, Colleen A. [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); Amdur, Robert J. [Department of Radiation Oncology, University of Florida Shands Cancer Center, Gainesville, FL (United States)

2009-06-01T23:59:59.000Z

304

Coal liquefaction process streams characterization and evaluation. Characterization of coal liquefaction resids employing thermogravimetric analysis and electron spin resonance spectroscopy  

DOE Green Energy (OSTI)

This study demonstrated the feasibility of using temperature-programmed electron spin resonance (ESR) and thermogravimetric analysis (TGA) for the examination of tetrahydrofuran (THF)-soluble distillation resid materials derived from direct coal liquefaction. TGA is used to quantitate volatile losses in a temperature-programmed experiment. The TGA data are used to correct the free radical densities obtained by ESR as volatile material is evolved from the samples in the temperature-programmed ESR experiment. The techniques, when employed in tandem, can be used to determine the content and nature of the free radicals in the samples at temperatures approximating those used in the liquefaction process. TGA and ESR experiments were performed in flowing nitrogen and hydrogen, at ambient pressure. No significant difference was observed in the ESR spectra in the different atmospheres, except in the case of low-rank coal-derived resids. The TGA results, however, were systematically different; mass loss in an H{sub 2} atmosphere is consistently higher than that observed in an N{sub 2} atmosphere. It was shown that temperature-programmed ESR, which can pinpoint conditions at which the free radical content is the highest, has potential to be a guide for the appropriate choice of conditions for optimum resid upgrading. Further development of these combined analytical methods as process development tools appears justified based on these results.

Ibrahim, M.M.; Seehra, M.S. [West Virginia Univ., Morgantown, WV (United States). Dept. of Physics

1992-10-01T23:59:59.000Z

305

Resident Fish Stock Status above Chief Joseph and Grand Coulee Dams; 2000 Annual Report.  

DOE Green Energy (OSTI)

The Resident Fish Stock Status above Chief Joseph and Grand Coulee Dams Project, commonly known as the Joint Stock Assessment Project (JSAP) is a management tool using ecosystem principles to manage artificial fish assemblages and native fish in altered environments existing in the Columbia River System above Chief Joseph and Grand Coulee Dams (blocked area). The three-phase approach of this project will enhance the fisheries resources of the blocked area by identifying data gaps, filling data gaps with research, and implementing management recommendations based on research results. The Blocked Area fisheries information housed in a central location will allow managers to view the entire system while making decisions, rather than basing management decisions on isolated portions of the system. The JSAP (NWPPC program measure 10.8B.26) is designed and guided jointly by fisheries managers in the blocked area and the Columbia Basin blocked area management plan (1998). The initial year of the project (1997) identified the need for a central data storage and analysis facility, coordination with the StreamNet project, compilation of blocked area fisheries information, and a report on the ecological condition of the Spokane River System. These needs were addressed in 1998 by acquiring a central location with a data storage and analysis system, coordinating a pilot project with StreamNet, compiling fisheries distribution data throughout the blocked area, identifying data gaps based on compiled information, and researching the ecological condition of the Spokane River. In order to ensure that any additional information collected throughout the life of this project will be easily stored and manipulated by the central storage facility, it was necessary to develop standardized methodologies between the JSAP fisheries managers. The use of common collection and analytical tools is essential to the process of streamlining joint management decisions. In 1999 and 2000 the project began to address some of the identified data gaps, throughout the blocked area, with a variety of newly developed sampling projects, as well as, continuing with ongoing data collection of established projects.

Crossley, Brian (Spokane Tribe of Indians, Department of Natural Resources, Wellpinit, WA); Lockwood, Jr., Neil W. (Kalispel Tribe of Indians, Usk, WA); McLellan, Jason G. (Washington Department of Fish and Wildlife, Spokane, WA)

2001-01-01T23:59:59.000Z

306

Small Residence Multizone Modeling with Partial Conditioning for Energy Effieiency in Hot and Humid Climates  

E-Print Network (OSTI)

The purpose of this study is to reduce the energy cost of the low-income households in the hot and humid climates of the U.S. and thereby to help them afford comfortable homes. In this perspective, a new HVAC energy saving strategy, i.e. partial conditioning was modeled and its potential to reduce the HVAC energy consumption of the low income homes in Texas was quantified. The partial conditioning strategy combined three primary ideas: 1) using historic courtyard building schemes to provide a buffer zone between conditioned spaces, 2) zoning and applying occupancy based heating/cooling in each zone, and 3) reusing the conditioned air returning from the occupied zones in the unoccupied zones before it is returned to the system. The study was conducted in four steps: 1) data collection, 2) baseline design and modeling, 3) partial conditioning design and modeling, and 4) analyses and recommendations. First, a site visit was held to the Habitat for Humanity office in Bryan, Texas to collect data on the characteristics of the Habitat for Humanity houses built in Bryan. Second, a base-line Habitat for Humanity house was designed and modeled based on this information along with multiple other resources including International Energy Conservation Code 2012 and Building America benchmark definitions. A detailed comparison was made between the commonly used energy modeling tools (DOE-2.1e, EnergyPlus and TRNSYS) and a modeling method was developed for the estimation of the baseline energy consumption. Third, the partial conditioning strategy was introduced into the baseline energy model to simulate a partially conditioned atrium house. As the occupied zone and the direction of the airflow changed throughout the year in the partially conditioned house, this step required an innovative air loop model with interzonal air ducts that allowed for sched- uled bi-directional airflow. This air loop was modeled with the AirflowNetwork model of EnergyPlus. Fourth, the modeling results were analyzed and discussed to determine the performance of the partial conditioning strategy in a hot and humid climate. It was found that partial conditioning strategy can provide substantial (37%-46%) reduction in the overall HVAC energy consumption of small residences (?1,000 ft2) in hot and humid climates while performing better in meeting the temperature set points in each room. It was also found that the quantity of the energy savings that can be obtained with the partial conditioning strategy depends significantly on the ground coupling condition of the house for low rise residential buildings.

Andolsun, Simge

2013-08-01T23:59:59.000Z

307

Impacts of Vessel Noise Perturbations on the Resident Sperm Whale Population in the Gulf of Mexico  

E-Print Network (OSTI)

The Gulf of Mexico is home to two of the world?s ten busiest ports by cargo volume, the Port of New Orleans and the Port of Houston; and in 2008, these ports hosted a combined 14,000 ships, a number which is likely only to increase. Past research shows that this increase in shipping worldwide has historically lead to an increase in ambient noise level of 3-5dB per decade. Sperm whales in the Gulf of Mexico are considered a genetically distinct, resident population. They have a preference for the Louisiana-Mississippi Shelf region which directly overlaps with the entrance to the Mississippi and the Port of New Orleans. Disruptions from vessel noise could influence feeding and breeding patterns essential to the health of the stock. Data used in this analysis were collected continuously over 36 days in the summer of 2001 from bottom moored Navy Environmental Acoustic Recording System (EARS) buoys. Results showed a significant difference (P<0.05) in noise level between hours with ships passing and hours without. Metrics for 56 ship passages were analyzed to compare duration of ship passage with duration of maximum received level (MRL) during ship passage. Results of that analysis showed an average ship passage of 29 minutes with average MRL lasting 23% of the ship passage and an average increase of 40dB. Lastly, click counts were made with the Pamguard. Click counts for ship passages were completed for 35 min and 17.5 min before and after the estimated closest point of approach (CPA) for each ship. Results showed a 36% decrease in the number of detectable clicks as a ship approaches when comparing clicks detected at intervals of both 35 minutes before and 17 minutes before the CPA; additionally, 22% fewer clicks were counted 30 min after the ship than 30 min before (results significant at the P=0.01 level). These results indicate a potential change in sperm whale behavior when exposed to large class size vessel traffic (e.g. tankers and container ships) from major shipping lanes. Recommendations for addressing this issue are discussed.

Azzara, Alyson

2012-05-01T23:59:59.000Z

308

An evaluation of the bioclimatic chart for choosing design strategies for a thermostatically-controlled residence in selected climates  

E-Print Network (OSTI)

To be successful in sustainable building design, architects must consider energy efficient design strategies in the early design stage. Unfortunately, many architects still rely on simplified analysis, synthesis techniques, and historical examples. Although, building energy simulations are becoming more common in the design of buildings, architects rarely use simulation in the early design stage. The "Bioclimatic" charts have been used in the early design stage to define potential building design strategies to achieve indoor thermal comfort. Currently, many architects use the Givoni-Milne bioclimatic design chart (Milne and Givoni, 1979), which was developed based on principle reasoning and heuristics. There have been many attempts to develop computerized programs to further the bioclimatic analysis; however, there have been very limited efforts to test and evaluate the design strategies of the chart using simulations of a thermostatically-controlled building. Therefore, the purpose of this research is to promote comfortable buildings that reduce energy use through appropriate building design strategies. The objectives of the research are to develop a more accurate bioclimatic chart for a thermostaticallycontrolled residence by testing and evaluating the Givoni-Milne bioclimatic chart. The analysis is performed with DOE-2.1e program (Winkelmann, 1993) and TMY2 weather data (Marion and Urban, 1995) for several climates. To achieve these objectives, four main tasks were accomplished: 1) investigate the Givoni-Milne Bioclimatic Chart using representative weather data from several climates, 2) analyze and modify the design strategy boundaries using DOE-2 program and TMY2 weather data to simulate the effects of varied conditions of a thermostatically-controlled residence in different climates, 3) compare these new design strategy boundaries to the original Givoni-Milne design strategy boundaries, and 4) develop general guidelines for the new bioclimatic chart. In summary, there were some differences in the results from the Givoni-Milne bioclimatic chart and the DOE-2 simulation results. These results imply that without further modification, the G-M Chart may have only a limited use for a thermostaticallycontrolled residence. Therefore, to improve the usefulness of the bioclimatic chart the new bio-climatic chart for choosing design strategies for a thermostatically-controlled residence in the hot-humid climate of Houston, Texas, was developed. This new bioclimatic chart for a thermostatically-controlled residence will be a useful tool for architects and engineers in the early design stage. Similar versions of the new bioclimatic for other climates could then be developed.

Visitsak, Sopa

2007-12-01T23:59:59.000Z

309

An Evaluation of the Bioclimatic Chart for Choosing Design Strategies for a Thermostatically-controlled Residence in Selected Climates  

E-Print Network (OSTI)

To be successful in sustainable building design, architects must consider energy efficient design strategies in the early design stage. Unfortunately, many architects still rely on simplified analysis, synthesis techniques, and historical examples. Although, building energy simulations are becoming more common in the design of buildings, architects rarely use simulation in the early design stage. The Bioclimatic charts have been used in the early design stage to define potential building design strategies to achieve indoor thermal comfort. Currently, many architects use the Givoni-Milne bioclimatic design chart (Milne and Givoni, 1979), which was developed based on principle reasoning and heuristics. There have been many attempts to develop computerized programs to further the bioclimatic analysis; however, there have been very limited efforts to test and evaluate the design strategies of the chart using simulations of a thermostatically-controlled building. Therefore, the purpose of this research is to promote comfortable buildings that reduce energy use through appropriate building design strategies. The objectives of the research are to develop a more accurate bioclimatic chart for a thermostaticallycontrolled residence by testing and evaluating the Givoni-Milne bioclimatic chart. The analysis is performed with DOE-2.1e program (Winkelmann, 1993) and TMY2 weather data (Marion and Urban, 1995) for several climates. To achieve these objectives, four main tasks were accomplished: 1) investigate the Givoni-Milne Bioclimatic Chart using representative weather data from several climates, 2) analyze and modify the design strategy boundaries using DOE-2 program and TMY2 weather data to simulate the effects of varied conditions of a thermostatically-controlled residence in different climates, 3) compare these new design strategy boundaries to the original Givoni-Milne design strategy boundaries, and 4) develop general guidelines for the new bioclimatic chart. In summary, there were some differences in the results from the Givoni-Milne bioclimatic chart and the DOE-2 simulation results. These results imply that without further modification, the G-M Chart may have only a limited use for a thermostaticallycontrolled residence. Therefore, to improve the usefulness of the bioclimatic chart the new bio-climatic chart for choosing design strategies for a thermostatically-controlled residence in the hot-humid climate of Houston, Texas, was developed. This new bioclimatic chart for a thermostatically-controlled residence will be a useful tool for architects and engineers in the early design stage. Similar versions of the new bioclimatic for other climates could then be developed.

Visitsak, Sopa

2007-12-01T23:59:59.000Z

310

An evaluation of the bioclimatic chart for choosing design strategies for a thermostatically-controlled residence in selected climates  

E-Print Network (OSTI)

To be successful in sustainable building design, architects must consider energy efficient design strategies in the early design stage. Unfortunately, many architects still rely on simplified analysis, synthesis techniques, and historical examples. Although, building energy simulations are becoming more common in the design of buildings, architects rarely use simulation in the early design stage. The Bioclimatic charts have been used in the early design stage to define potential building design strategies to achieve indoor thermal comfort. Currently, many architects use the Givoni-Milne bioclimatic design chart (Milne and Givoni, 1979), which was developed based on principle reasoning and heuristics. There have been many attempts to develop computerized programs to further the bioclimatic analysis; however, there have been very limited efforts to test and evaluate the design strategies of the chart using simulations of a thermostatically-controlled building. Therefore, the purpose of this research is to promote comfortable buildings that reduce energy use through appropriate building design strategies. The objectives of the research are to develop a more accurate bioclimatic chart for a thermostaticallycontrolled residence by testing and evaluating the Givoni-Milne bioclimatic chart. The analysis is performed with DOE-2.1e program (Winkelmann, 1993) and TMY2 weather data (Marion and Urban, 1995) for several climates. To achieve these objectives, four main tasks were accomplished: 1) investigate the Givoni-Milne Bioclimatic Chart using representative weather data from several climates, 2) analyze and modify the design strategy boundaries using DOE-2 program and TMY2 weather data to simulate the effects of varied conditions of a thermostatically-controlled residence in different climates, 3) compare these new design strategy boundaries to the original Givoni-Milne design strategy boundaries, and 4) develop general guidelines for the new bioclimatic chart. In summary, there were some differences in the results from the Givoni-Milne bioclimatic chart and the DOE-2 simulation results. These results imply that without further modification, the G-M Chart may have only a limited use for a thermostaticallycontrolled residence. Therefore, to improve the usefulness of the bioclimatic chart the new bio-climatic chart for choosing design strategies for a thermostatically-controlled residence in the hot-humid climate of Houston, Texas, was developed. This new bioclimatic chart for a thermostatically-controlled residence will be a useful tool for architects and engineers in the early design stage. Similar versions of the new bioclimatic for other climates could then be developed.

Visitsak, Sopa

2007-12-01T23:59:59.000Z

311

Resident Fish Stock Status above Chief Joseph and Grand Coulee Dams; 2002-2003 Annual Report.  

DOE Green Energy (OSTI)

In 1980, the United States Congress enacted the Northwest Power Planning and Conservation Act (PL 96-501, 1980), which established the Northwest Power and Conservation Council (NPCC), formerly the Northwest Power Planning Council. The NPCC was directed by Congress to develop a regional Power Plan and also the Columbia River Basin Fish and Wildlife Program (FWP) to restore or replace losses of fish caused by construction and operation of hydroelectric dams in the Columbia River Basin. In developing the FWP, Congress specifically directed NPCC to solicit recommendations for measures to be included in the Program from the region's fish and wildlife agencies and Indian tribes. All measures adopted by the Council were also required to be consistent with the management objectives of the agencies and tribes [Section 4.(h)(6)(A)], the legal rights of Indian tribes in the region [Section 4.(h)(6)(D)] and be based upon and supported by the best available scientific knowledge [Section 4.(h)(6)(B)]. The Resident Fish Stock Status above Chief Joseph and Grand Coulee Dams Project, also known as the Joint Stock Assessment Project (JSAP) specifically addresses NPPC Council measure 10.8B.26 of the 1994 program. The Joint Stock Assessment Project is a management tool using ecosystem principles to manage artificial and native fish assemblages in altered environments existing in the Columbia River System above Chief Joseph and Grand Coulee Dams (Blocked Area). A three-phase approach of this project will enhance the fisheries resources of the Blocked Area by identifying data gaps, filling data gaps with research, and implementing management recommendations based on research results. The Blocked Area fisheries information is housed in a central location, allowing managers to view the entire system while making decisions, rather than basing management decisions on isolated portions of the system. The JSAP is designed and guided jointly by fisheries managers in the Blocked Area. The initial year of the project (1997) identified the need for a central data storage and analysis facility, coordination with the StreamNet project, compilation of Blocked Area fisheries information, and a report on the ecological condition of the Spokane River System. These needs were addressed in 1998 by acquiring a central location with a data storage and analysis system, coordinating a pilot project with StreamNet, compiling fisheries distribution data throughout the Blocked Area, identifying data gaps based on compiled information, and researching the ecological condition of the Spokane River. In order to ensure that any additional information collected throughout the life of this project will be easily stored and manipulated by the central storage facility, it was necessary to develop standardized methodologies between the JSAP fisheries managers. Common collection and analytical methodologies were developed in 1999. The project began addressing identified data gaps throughout the Blocked Area in 1999. Data collection of established projects and a variety of newly developed sampling projects are ongoing. Projects developed and undertaken by JSAP fisheries managers include investigations of the Pend Orielle River and its tributaries, the Little Spokane River and its tributaries, and water bodies within and near the Spokane Indian Reservation. Migration patterns of adfluvial and reservoir fish in Box Canyon Reservoir and its tributaries, a baseline assessment of Boundary Reservoir and its tributaries, ecological assessment of mountain lakes in Pend Oreille County, and assessments of streams and lakes on the Spokane Indian Reservation were completed by 2001. Assessments of the Little Spokane River and its tributaries, Spokane River below Spokane Falls, tributaries to the Pend Oreille River, small lakes in Pend Oreille County, WA, and water bodies within and near the Spokane Indian Reservation were conducted in 2002 and 2003. This work was done in accordance with the scope of work approved by Bonneville Power Administration (BPA).

Connor, Jason M. (Kalispel Tribe of Indians, Usk, WA); McLellan, Jason G. (Washington Department of Fish and Wildlife); Butler, Chris (Spokane Tribe of Indians, Wellpinit, WA)

2006-02-01T23:59:59.000Z

312

Resident Fish Stock above Chief Joseph and Grand Coulee Dams; 2002 Annual Report.  

DOE Green Energy (OSTI)

In 1980, the United States Congress enacted the Northwest Power Planning and Conservation Act (PL 96-501, 1980), which established the Northwest Power and Conservation Council (NPCC), formerly the Northwest Power Planning Council. The NPCC was directed by Congress to develop a regional Power Plan and also the Columbia River Basin Fish and Wildlife Program (FWP) to restore or replace losses of fish caused by construction and operation of hydroelectric dams in the Columbia River Basin. In developing the FWP, Congress specifically directed NPCC to solicit recommendations for measures to be included in the Program from the region's fish and wildlife agencies and Indian tribes. All measures adopted by the Council were also required to be consistent with the management objectives of the agencies and tribes [Section 4.(h)(6)(A)], the legal rights of Indian tribes in the region [Section 4.(h)(6)(D)] and be based upon and supported by the best available scientific knowledge [Section 4.(h)(6)(B)]. The Resident Fish Stock Status above Chief Joseph and Grand Coulee Dams Project, also known as the Joint Stock Assessment Project (JSAP) specifically addresses NPPC Council measure 10.8B.26 of the 1994 program. The Joint Stock Assessment Project is a management tool using ecosystem principles to manage artificial fish assemblages and native fish in altered environments existing in the Columbia River System above Chief Joseph and Grand Coulee Dams (Blocked Area). A three-phase approach of this project will enhance the fisheries resources of the Blocked Area by identifying data gaps, filling data gaps with research, and implementing management recommendations based on research results. The Blocked Area fisheries information is housed in a central location, allowing managers to view the entire system while making decisions, rather than basing management decisions on isolated portions of the system. The JSAP is designed and guided jointly by fisheries managers in the Blocked Area. The initial year of the project (1997) identified the need for a central data storage and analysis facility, coordination with the StreamNet project, compilation of Blocked Area fisheries information, and a report on the ecological condition of the Spokane River System. These needs were addressed in 1998 by acquiring a central location with a data storage and analysis system, coordinating a pilot project with StreamNet, compiling fisheries distribution data throughout the Blocked Area, identifying data gaps based on compiled information, and researching the ecological condition of the Spokane River. In order to ensure that any additional information collected throughout the life of this project will be easily stored and manipulated by the central storage facility, it was necessary to develop standardized methodologies between the JSAP fisheries managers. Common collection and analytical methodologies were developed in 1999. In 1999, 2000, and 2001 the project began addressing some of the identified data gaps throughout the Blocked Area. Data collection of established projects and a variety of newly developed sampling projects are ongoing. Projects developed and undertaken by JSAP fisheries managers include investigations of the Pend Orielle River and its tributaries, the Little Spokane River and its tributaries, and water bodies within and near the Spokane Indian Reservation. Migration patterns of adfluvial and reservoir fish in Box Canyon Reservoir and its tributaries, a baseline assessment of Boundary Reservoir and its tributaries, ecological assessment of mountain lakes in Pend Oreille County, and assessments of streams and lakes on the Spokane Indian Reservation were completed by 2001. Assessments of the Little Spokane River and its tributaries, tributaries to the Pend Oreille River, small lakes in Pend Oreille County, WA, and water bodies within and near the Spokane Indian Reservation were conducted in 2002. This work was done in accordance with the scope of work approved by Bonneville Power Administration (BPA).

Connor, Jason M. (Kalispel Department of Natural Resources, Usk, WA); McLellan, Jason G. (Washington Department of Fish and Wildlife, Spokane, WA); Butler, Chris (Spokane Tribe of Indians, Department of Natural Resources, Wellpinit, WA)

2003-09-01T23:59:59.000Z

313

Resident Fish Stock above Chief Joseph and Grand Coulee Dams; 2003-2004 Annual Report.  

DOE Green Energy (OSTI)

In 1980, the United States Congress enacted the Northwest Power Planning and Conservation Act (PL 96-501, 1980), which established the Northwest Power and Conservation Council (NPCC), formerly the Northwest Power Planning Council. The NPCC was directed by Congress to develop a regional Power Plan and also the Columbia River Basin Fish and Wildlife Program (FWP) to restore or replace losses of fish caused by construction and operation of hydroelectric dams in the Columbia River Basin. In developing the FWP, Congress specifically directed NPCC to solicit recommendations for measures to be included in the Program from the region's fish and wildlife agencies and Indian tribes. All measures adopted by the Council were also required to be consistent with the management objectives of the agencies and tribes [Section 4.(h)(6)(A)], the legal rights of Indian tribes in the region [Section 4.(h)(6)(D)] and be based upon and supported by the best available scientific knowledge [Section 4.(h)(6)(B)]. The Resident Fish Stock Status above Chief Joseph and Grand Coulee Dams Project, also known as the Joint Stock Assessment Project (JSAP) specifically addresses NPPC Council measure 10.8B.26 of the 1994 program. The Joint Stock Assessment Project is a management tool using ecosystem principles to manage artificial and native fish assemblages in altered environments existing in the Columbia River System above Chief Joseph and Grand Coulee Dams (Blocked Area). A three-phase approach of this project will enhance the fisheries resources of the Blocked Area by identifying data gaps, filling data gaps with research, and implementing management recommendations based on research results. The Blocked Area fisheries information is housed in a central location, allowing managers to view the entire system while making decisions, rather than basing management decisions on isolated portions of the system. The JSAP is designed and guided jointly by fisheries managers in the Blocked Area. The initial year of the project (1997) identified the need for a central data storage and analysis facility, coordination with the StreamNet project, compilation of Blocked Area fisheries information, and a report on the ecological condition of the Spokane River System. These needs were addressed in 1998 by acquiring a central location with a data storage and analysis system, coordinating a pilot project with StreamNet, compiling fisheries distribution data throughout the Blocked Area, identifying data gaps based on compiled information, and researching the ecological condition of the Spokane River. In order to ensure that any additional information collected throughout the life of this project will be easily stored and manipulated by the central storage facility, it was necessary to develop standardized methodologies between the JSAP fisheries managers. Common collection and analytical methodologies were developed in 1999. The project began addressing identified data gaps throughout the Blocked Area in 1999. Data collection of established projects and a variety of newly developed sampling projects are ongoing. Projects developed and undertaken by JSAP fisheries managers include investigations of the Pend Orielle River and its tributaries, the Little Spokane River and its tributaries, and water bodies within and near the Spokane Indian Reservation. Migration patterns of adfluvial and reservoir fish in Box Canyon Reservoir and its tributaries, a baseline assessment of Boundary Reservoir and its tributaries, ecological assessment of mountain lakes in Pend Oreille County, and assessments of streams and lakes on the Spokane Indian Reservation were completed by 2001. Assessments of the Little Spokane River and its tributaries, Spokane River below Spokane Falls, tributaries to the Pend Oreille River, small lakes in Pend Oreille County, WA, and water bodies within and near the Spokane Indian Reservation were conducted in 2002 and 2003. This work was done in accordance with the scope of work approved by Bonneville Power Administration (BPA).

Connor, Jason M. (Kalispel Tribe of Indians, Usk, WA); McLellan, Jason G. (Washington Department of Fish and Wildlife, Olympia, WA); Butler, Chris (Spokane Tribe of Indians, Wellpinit, WA)

2005-11-01T23:59:59.000Z

314

Resident Fish Stock Status above Chief Joseph and Grand Coulee Dams; 2001 Annual Report.  

DOE Green Energy (OSTI)

In 1980, the United States Congress enacted the Northwest Power Planning and Conservation Act (PL 96-501, 1980), which established the Northwest Power Planning Council (NPPC). The NPPC was directed by Congress to develop a regional Power Plan and also the Columbia River Basin Fish and Wildlife Program (FWP) to restore or replace losses of fish caused by construction and operation of hydroelectric dams in the Columbia River Basin. In developing the FWP, Congress specifically directed NPPC to solicit recommendations for measures to be included in the Program from the region's fish and wildlife agencies and Indian tribes. All measures adopted by the Council were also required to be consistent with the management objectives of the agencies and tribes [Section 4.(h)(6)(A)], the legal rights of Indian tribes in the region [Section 4.(h)(6)(D)] and be based upon and supported by the best available scientific knowledge [Section 4.(h)(6)(B)]. The Resident Fish Stock Status above Chief Joseph and Grand Coulee Dams Project, also known as the Joint Stock Assessment Project (JSAP) specifically addresses NPPC Council measure 10.8B.26 of the 1994 program. The Joint Stock Assessment Project is a management tool using ecosystem principles to manage artificial fish assemblages and native fish in altered environments existing in the Columbia River System above Chief Joseph and Grand Coulee Dams (Blocked Area). A three-phase approach of this project will enhance the fisheries resources of the Blocked Area by identifying data gaps, filling data gaps with research, and implementing management recommendations based on research results. The Blocked Area fisheries information is housed in a central location, allowing managers to view the entire system while making decisions, rather than basing management decisions on isolated portions of the system. The JSAP is designed and guided jointly by fisheries managers in the Blocked Area and the Columbia Basin Blocked Area Management Plan (1998). The initial year of the project (1997) identified the need for a central data storage and analysis facility, coordination with the StreamNet project, compilation of Blocked Area fisheries information, and a report on the ecological condition of the Spokane River System. These needs were addressed in 1998 by acquiring a central location with a data storage and analysis system, coordinating a pilot project with StreamNet, compiling fisheries distribution data throughout the Blocked Area, identifying data gaps based on compiled information, and researching the ecological condition of the Spokane River. In order to ensure that any additional information collected throughout the life of this project will be easily stored and manipulated by the central storage facility, it was necessary to develop standardized methodologies between the JSAP fisheries managers. Common collection and analytical methodologies were developed in 1999. In 1999, 2000, and 2001 the project began addressing some of the identified data gaps throughout the Blocked Area. Data collection of established projects and a variety of newly developed sampling projects are ongoing. Projects developed and undertaken by JSAP fisheries managers include investigations of the Pend Orielle River and its tributaries, the Little Spokane River and its tributaries, and water bodies within and near the Spokane Indian Reservation. Migration patterns of adfluvial and reservoir fish in Box Canyon Reservoir and its tributaries, a baseline assessment of Boundary Reservoir and its tributaries, ecological assessment of mountain lakes in Pend Oreille County, and assessments of seven streams and four lakes on the Spokane Indian Reservation were completed by 2000. Assessments of the Little Spokane River and its tributaries, tributaries to the Pend Oreille River, small lakes in southern Pend Oreille County, and water bodies within and near the Spokane Indian Reservation were conducted in 2001. This work was done in accordance with the scope of work approved by Bonneville Power Administration (BPA).

Connor, Jason M. (Kalispell Department of Natural Resources, Usk, WA); McLellan, Jason G. (Washington Department of Fish and Wildlife, Spokane, WA); O'Connor, Dick (Washington Department of Fish and Wildlife, Olympia, WA)

2003-01-01T23:59:59.000Z

315

Southern Nevada residents` views about the Yucca Mountain high-level nuclear waste repository and related issues: A comparative analysis of urban and rural survey data  

SciTech Connect

two separate surveys were undertaken in 1988 to ascertain southern Nevadans` views about the Yucca Mountain repository and related issues. The first of these studies focused on the attitudes and perceptions of residents in the Las Vegas metropolitan area. The second study addressed similar issues, but focused on the views of residents in six rural communities in three counties adjacent to the Yucca Mountain site. However, parallel findings from the two data sets have not been jointly analyzed in order to identify ways in which the views and orientations of residents in the rural and urban study areas may be similar or different. The purpose of this report is to develop and present a comparative assessment of selected issues addressed in the rural and urban surveys. Because both urban and rural populations would potentially be impacted by the Yucca Mountain repository, such an analysis will provide important insights into possible repository impacts on the well-being of residents throughout southern Nevada.

Krannich, R.S.; Little, R.L. [Utah State Univ., Logan, UT (United States); Mushkatel, A.; Pijawka, K.D.; Jones, P. [Arizona State Univ., Tempe, AZ (United States)

1991-10-01T23:59:59.000Z

316

Genetic and Phenotypic Catalog of Native Resident Trout of the Interior Columbia River Basin; Populations of the Upper Yakima Basin, 1997-1998 Annual Report.  

DOE Green Energy (OSTI)

The objective of this project is to photo-document upper Columbia Basin native resident trout populations in Washington, and to ascertain their species or subspecies identity and relative genetic purity using a nonlethal DNA technique.

Trotter, Patrick C. (Fishery Science Consultant, Seattle, WA); McMillan, Bill; Gayeski, Nick (Washington Trout, Duvall, WA)

1999-10-01T23:59:59.000Z

317

Effects of Dissolved Gas Supersaturation on Fish Residing in the Snake and Columbia Rivers, 1996 Annual Report.  

DOE Green Energy (OSTI)

Increased spill at dams has commonly brought dissolved gas supersaturation higher than levels established by state and federal water quality criteria in the Columbia and Snake Rivers. These increased spill volumes are intended to provide safe passage for migrating juvenile salmon. However, dissolved gas supersaturation resulting from spill in past decades has led to gas bubble disease (GBD) in fish. Therefore, during the period of high spill in 1996, the authors monitored the prevalence and severity of gas bubble disease by sampling resident fish in Priest Rapids Reservoir and downstream from Bonneville, Priest Rapids, and Ice Harbor Dams.

Schrank, Boyd P.

1998-03-01T23:59:59.000Z

318

Copyright ? The Korean Academy of Medical Sciences ? BRIEF COMMUNICATION? Biological Profiles of Korean Atomic Bomb Survivors in Residence at  

E-Print Network (OSTI)

In 1945, many Koreans, in addition to Japanese, were killed or injured by the atomic bombs dropped on Hiroshima and Nagasaki, Japan. This study compared the biological profiles of Korean atomic bomb survivors in residence at Daegu and Kyungbuk, Republic of Korea with those of a representative sample of Koreans obtained during a similar period. We evaluated anthropometric measurements, blood pressure, blood cell counts, blood chemistry, and urinalysis of survivors (n=414) and age- and sex-matched controls (n=414) recruited from the third Korea National Health and Nutrition Examination Survey conducted in 2005. Univariate analyses revealed significantly higher systolic blood pressure, white blood cell count, and serum total cholesterol, triglycerides, high-density lipoprotein-cholesterol, and aspartate aminotransferase levels (patomic bomb survivors were adversely affected by radiation exposure.

Republic Of Korea; Hyung-joon Jhun; Byoung-gwon Kim; Bon-min Koo; Jin-kook Kim

2007-01-01T23:59:59.000Z

319

Statewide Electricity and Demand Capacity Savings from the Implementation of IECC Code in Texas: Analysis for Single-Family Residences  

E-Print Network (OSTI)

This paper presents estimates of the statewide electricity and electric demand savings achieved from the adoption of the International Energy Conservation Code (IECC) for single-family residences in Texas and includes the corresponding increase in construction costs over the eight-year period from 2002 through 2009. Using the Energy Systems Laboratory's International Code Compliance Calculator (IC3) simulation tool, the annual statewide electricity savings in 2009 are estimated to be $161 million. The statewide peak electric demand reductions in 2009 are estimated to be 694 MW for the summer and 766 MW for the winter periods. Since 2002, the cumulative statewide electricity and electric demand savings over the eight year period from 2002 to 2009 are $1,803 million ($776 million from electricity savings and $1,027 million from electric demand savings) while the total increased costs are estimated to be $670 million.

Kim, H.; Baltazar, J.C.; Haberl, J.

2011-01-01T23:59:59.000Z

320

Idaho Water Rental Pilot Project probability/coordination study resident fish and wildlife impacts, Phase III. Annual report  

DOE Green Energy (OSTI)

Phase III began in 1995 with the overall goal of quantifying changes in resident fish habitat in the Snake River basin upstream of Brownlee Reservoir resulting from the release of salmon flow augmentation water. Existing data, in the form of weighted usable area versus flow relationships, were used to estimate habitat changes for white sturgeon (Acipenser transmontanus) and rainbow trout (Oncorhynchus mykiss)in the Snake River between C.J. Strike Dam and Brownlee pool. The increased flows resulted in increased white sturgeon habitat for most life stages. Rainbow trout adult and spawning habitat increased while juvenile and fry habitat generally decreased. Whether or not these short term increases in habitat result in long term benefits to the fish populations has yet to be determined.

Leitzinger, E.

1996-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Effects of Dissolved Gas Supersaturation on Fish Residing in the Snake and Columbia Rivers, 1997 Annual Report.  

DOE Green Energy (OSTI)

Large amounts of spill at dams has commonly generated levels of dissolved gas supersaturation that are higher than levels established by state and federal agencies setting criteria for acceptable water quality in the Columbia and Snake Rivers. Large spill volumes are sometimes provided voluntarily to increase the proportion of migrating juvenile salmon that pass dams through nonturbine routes. However, total dissolved gas supersaturation (TDGS) resulting from spill in past decades has led to gas bubble disease (GBD) in fish. Therefore, during the period of high spill in 1997, the authors monitored the prevalence and severity of gas bubble disease by sampling resident fish in Ice Harbor reservoir and downstream from Ice Harbor and Bonneville Dams.

Ryan, Brad A.

1998-04-01T23:59:59.000Z

322

TRACER: an EXCEL workbook to calculate mean residence time in groundwater by use of tracers CFC-11, CFC-12 and tritium  

Science Conference Proceedings (OSTI)

An EXCEL workbook is presented for calculating the mean residence time of groundwater based on the environmental tracers, tritium, CFC-11 and CFC-12. The program TRACER is written in Visual Basic for Application language and uses piston, exponential, ... Keywords: environmental tracer, exit-age distribution, exponential model, piston flow, turnover time

Serdar Bayari

2002-06-01T23:59:59.000Z

323

Using a three-dimensional particle-tracking model to estimate the residence time and age of water in a tidal estuary  

Science Conference Proceedings (OSTI)

A three-dimensional hydrodynamic model that includes a Lagrangian particle-tracking simulation was applied to the Danshuei River estuarine system in northern Taiwan. The model's accuracy was validated with data from 1999; the results from the model agreed ... Keywords: Age, Currents, Freshwater discharge, Models, Particle tracking, Residence time, Salinity

Wen-Cheng Liu; Wei-Bo Chen; Ming-Hsi Hsu

2011-08-01T23:59:59.000Z

324

Annual Report on Resident Fish Activities, 1985 Fiscal Year, Columbia River Basin Fish and Wildlife Program, Action Item 41.8.  

Science Conference Proceedings (OSTI)

This report addresses the status for resident fish projects currently implemented by the Bonneville Power Administration under the amended Columbia River Basin Fish and Wildlife Program. Projects that have been in place for a sufficient length of time are discussed in greater detail with a brief evaluation presented.

United States. Bonneville Power Administration.

1985-09-01T23:59:59.000Z

325

CIRES/SWPC Research Associate CIRES invites applications to fill a research associate position resident at the Space Weather Prediction Center to  

E-Print Network (OSTI)

resident at the Space Weather Prediction Center to support the recently announced DSCOVR solar wind mission. SWPC will be receiving calibrated, processed data in near-real-time from the DSCOVR solar wind plasma and magnetometer instruments. CIRES is looking for applicants capable of producing science quality space weather

Colorado at Boulder, University of

326

Relationship between leukemia incidence and residing and/or working near the Pilgrim 1 nuclear power plant in Plymouth, Massachusetts  

Science Conference Proceedings (OSTI)

To determine whether a strong association between leukemia incidence between 1978 and 1986 and potential for exposure to radiation emitted from the Pilgrim 1 nuclear power plant in Plymouth, Massachusetts was a spurious finding resulting from either (1) failure to account for temporal variation in the level of radioactivity released from the plant or (2) inattention to certain potentially confounding factors, additional age/sex-matched case-control analyses controlled for the effects of socioeconomic status (SES), work history, and cigarette smoking were performed with data collected in the Southeastern Massachusetts Health Investigation -- a study of leukemia among residents aged 13 and older of 22 southeastern Massachusetts towns. None of the additional analyses, including incorporation of emissions data into the exposure-assessment scheme and crude attempts to control for (1) medical-radiation exposure, (2) potential for exposure to pesticides sprayed on cranberry bogs, or (3) workplace exposure to radiation, chemical solvents, dust, or fumes, altered the finding of a statistically significant dose-response relationship between leukemia incidence and potential for exposure to radioactive emissions. The trend in the association over time was not entirely consistent, however, with the hypothesis that unusually large amounts of radioactivity reportedly released from the plant during the mid-1970s were responsible for the observed effects. Recommendations were made for further study of the Plymouth-area population for studies of this problem elsewhere.

Morris, M.S.

1992-01-01T23:59:59.000Z

327

Estimated effective dose rates from radon exposure in workplaces and residences within Los Alamos county in New Mexico  

SciTech Connect

Many millions of office workers are exposed to radon while at work and at home. Though there has been a multitude of studies reporting the measurements of radon concentrations and potential lung and effective doses associated with radon and progeny exposure in homes, similar studies on the concentrations and subsequent effective dose rates in the workplace are lacking. The purposes of this study were to measure radon concentrations in office and residential spaces in the same county and explore the radiation dose implications. Sixty-five track-etch detectors were deployed in office spaces and 47 were deployed in residences, all within Los Alamos County, New Mexico, USA. The sampling periods for these measurements were generally about three months. The measured concentrations were then used to calculate and compare effective dose rates resulting from exposure while at work and at home. Results showed that full-time office workers receive on average about nine times greater exposure at home than while in the office (691 mrem yr{sup -1} versus 78 mrem yr{sup -1}). The estimated effective dose rate for a more homebound person was 896 mrem yr{sup -1}. These effective dose rates are contrasted against the 100 mrem yr{sup -1} threshold for regulation of a 'radiological worker' defined in the Department of Energy regulations occupational exposure and the 10 mrem yr{sup -1} air pathway effective public dose limit regulated by the Environmental Protection Agency.

Whicker, Jeffrey J [Los Alamos National Laboratory; Mcnaughton, Michael [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

328

Estimation of Citation-Based Scholarly Activity Among Radiation Oncology Faculty at Domestic Residency-Training Institutions: 1996-2007  

SciTech Connect

Purpose: Advancement in academic radiation oncology is largely contingent on research productivity and the perceived external influence of an individual's scholarly work. The purpose of this study was to use the Hirsch index (h-index) to estimate the research productivity of current radiation oncology faculty at U.S. academic institutions between 1996 and 2007. Methods and Materials: We performed bibliometric citation database searches for available radiation oncology faculty at domestic residency-training institutions (n = 826). The outcomes analyzed included the total number of manuscripts, total number of citations, and the h-index between 1996 and 2007. Analysis of overall h-index rankings with stratification by academic ranking, junior vs. senior faculty status, and gender was performed. Results: Of the 826 radiation oncologists, the mean h-index was 8.5. Of the individuals in the top 10% by the h-index, 34% were chairpersons, 88% were senior faculty, and 13% were women. A greater h-index was associated with a higher academic ranking and senior faculty status. Recursive partitioning analysis revealed an h-index threshold of 15 (p <0.0001) as an identified breakpoint between the senior and junior faculty. Overall, women had lower h-indexes compared with men (mean, 6.4 vs. 9.4); however, when stratified by academic ranking, the gender differential all but disappeared. Conclusion: Using the h-index as a partial surrogate for research productivity, it appears that radiation oncologists in academia today comprise a prolific group, however, with a highly skewed distribution. According to the present analysis, the h-index correlated with academic ranking. Thus, it potentially has utility in the process of promotion decisions. Overall, women in radiation oncology were less academically productive than men; the possible reasons for the gender differential are discussed.

Choi, Mehee [Department of Radiation Medicine, Oregon Health and Science University, Portland, OR (United States); Fuller, Clifton D. [Department of Radiation Medicine, Oregon Health and Science University, Portland, OR (United States); Department of Radiation Oncology, Division of Radiological Sciences, University of Texas Health Science Center at San Antonio, San Antonio, TX (United States); Department of Radiology, Division of Radiological Sciences, University of Texas Health Science Center at San Antonio, San Antonio, TX (United States); Thomas, Charles R. [Department of Radiation Medicine, Oregon Health and Science University, Portland, OR (United States)], E-mail: thomasch@ohsu.edu

2009-05-01T23:59:59.000Z

329

Estimates of Energy Cost Savings Achieved from 2009 IECC Code-Compliant, Single Family Residences in Texas  

E-Print Network (OSTI)

This report presents estimates of the energy cost savings to be achieved from 2009 International Energy Conservation Code (IECC) code-compliant, single-family residences in Texas compared to the pre-2009 IECC codes, including: the 2001 IECC, the 2006 IECC, and the 2006 IECC w/ Houston amendments (w/ HA). A series of simulations were performed using an ESL simulation model (BDL version 4.01.07 of IC3) based on the DOE-2.1e simulation and the appropriate TMY2 weather files for three counties representing three 2009 IECC Climate Zones across Texas: Harris County for Climate Zone 2, Tarrant County for Climate Zone 3, and Potter County for Climate Zone 4. Two options based on the choice of heating fuel type were considered: (a) an electric/gas house (gas-fired furnace for space heating, and gas water heater for domestic water heating), and (b) a heat pump house (heat pump for space heating, and electric water heater for domestic water heating). The base-case building was assumed to be a 2,325 sq. ft., square-shape, one story, single-family, detached house with a floor-to-ceiling height of 8 feet. The house has an attic with a roof pitched at 23 degrees. The base-case building envelope and system characteristics were determined from the general characteristics and the climate-specific characteristics as specified in the 2001 IECC, the 2006 IECC, the 2006 IECC w/HA, and the 2009 IECC. In addition, to facilitate a better comparison with the 2009 code, several modifications were applied to the pre-2009 IECC codes. As a result, the estimated annual energy cost savings per house associated with the 2009 IECC compared to the 2001 and 2006 IECC are: (a) an electric/gas house: $462/year and $206/year for Harris County, $432/year and $216/year for Tarrant County, and $576/year and $153/year for Potter County and (b) a heat pump house: $490/year and $203/year for Harris County, $487/year and $226/year for Tarrant County, and $680/year and $155/year for Potter County. The corresponding % savings of total energy cost of a 2009 IECC code-compliant house are: (a) an electric/gas house: 22.7% and 10.1% for Harris County, 21.8% and 10.9% for Tarrant County, and 28.9% and 7.7% for Potter County and (b) a heat pump house: 21.6% and 8.9% for Harris County, 20.9% and 9.7% for Tarrant County, and 25.7% and 5.8% for Potter County.

Kim, H.; Baltazar, J. C.; Haberl, J.

2011-01-01T23:59:59.000Z

330

The relationship between the bone mineral density and urinary cadmium concentration of residents in an industrial complex  

SciTech Connect

Background: An association between cadmium exposure and bone mineral density (BMD) has been demonstrated in elderly women, but has not been well studied in youths and men. Some studies report either no or a weak association between cadmium exposure and bone damage. Objectives: This study was designed to investigate the relationship between the urinary cadmium (U-Cd) levels and BMD of females and males of all ages. Methods: A total of 804 residents near an industrial complex were surveyed in 2007. U-Cd and BMD on the heel (non-dominant calcaneus) were analyzed with AAS-GTA and Dual-Energy X-ray absorptiometry, respectively. Demographic characteristics were collected by structured questionnaires. Osteoporosis and osteopenia were defined by BMD cut-off values and T-scores set by the WHO; T score>-1, normal; -2.5=}1.0 {mu}g/g creatinine) in females (OR=2.92; 95% CI, 1.51-5.64) and in males (OR=3.37; 95% CI, 1.09-10.38). With the multiple linear regression model, the BMD of the adult group was negatively associated with U-Cd (<0.05), gender (female, p<0.001) and age (p<0.001). The BMD of participants who were {<=}19 years of age was negatively associated with gender (female, p<0.01), whereas it was positively associated with age and BMI (p<0.001). BMD was not associated with exercise, smoking habits, alcohol consumption, job or parental education. Conclusion: Results suggested that U-Cd might be associated with osteopenia as well as osteoporosis in both male and female adults. Age and female gender were negatively associated with BMD in the adult group, whereas age was positively associated with BMD in the youth group. Cadmium exposure may be a potential risk factor for lower-BMD and osteopenia symptoms as well as for osteoporosis symptoms. - Research Highlights: {yields} The relationship between the urinary cadmium levels and BMD was investigated. {yields} U-Cd was associated with osteopenia and osteoporosis in adults. {yields} Cadmium exposure may be a potential risk factor for lower-BMD and osteopenia.

Shin, Minah; Paek, Domyung [Institute of Health and Environment, Department of Environmental Health, School of Public Health, Seoul National University, Gwanak-599, Gwanak-gu, Seoul 151-742 (Korea, Republic of)] [Institute of Health and Environment, Department of Environmental Health, School of Public Health, Seoul National University, Gwanak-599, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Yoon, Chungsik, E-mail: csyoon@snu.ac.kr [Institute of Health and Environment, Department of Environmental Health, School of Public Health, Seoul National University, Gwanak-599, Gwanak-gu, Seoul 151-742 (Korea, Republic of)] [Institute of Health and Environment, Department of Environmental Health, School of Public Health, Seoul National University, Gwanak-599, Gwanak-gu, Seoul 151-742 (Korea, Republic of)

2011-01-15T23:59:59.000Z

331

Modeling household adoption of earthquake hazard adjustments: a longitudinal panel study of Southern California and Western Washington residents  

E-Print Network (OSTI)

This research, aimed at advancing the theory of environmental hazard adjustment processes by contrasting households from three cities in a high seismic hazard area with households from three other cities in a moderate seismic hazard area. It identified seven types of stakeholders namely, the risk area residents and their families (primary group), the news media, employers, and friends (secondary group), and federal, state, and local governments (tertiary group), and explained why they are relevant to the adoption of seismic hazard adjustments. It also addressed three key attributesâ?? knowledge, trustworthiness, and responsibility for protectionâ??ascribed to these multiple stakeholders and the relationships of these stakeholder attributes with risk perception, hazard intrusiveness, hazard experience, gender, resource adequacy, fatalism and hazard adjustment adoption. It was specifically concerned with the effects of nested interactions due to trust and power differentials among the seven stakeholders, with the self reported adoption of 16 earthquake protective measures at two points in time (1997 and 1999). Some of the key findings indicate that risk perception, gender, fatalism, city activity in earthquake management and demographic characteristics did not significantly predict hazard adjustment adoption. However, all stakeholder characteristics had significant positive correlations with risk perception and hazard adjustment, implying a peripheral route for social influence. Hazard intrusiveness, hazard experience, and stakeholder knowledge, trustworthiness, and responsibility affected the increased adoption of hazard adjustments by households. Particularly important are the peer groupsâ?? (employers, friends and family) knowledge, trustworthiness and responsibility. These findings suggest, hazard managers cannot count only on the federal, state, and local government advisories put out through the news media to affect community decisions and thereby householdsâ?? decisions to take protective actions. Instead, hazard managers need to shift focus and work through peer group networks such as service organizations, industry groups, trade unions, neighborhood organizations, community emergency response teams, faith-based organizations, and educational institutions to increase the knowledge, trustworthiness and responsibility of all in the peer group. This will assure higher household hazard adjustment adoption levels, thus facilitating a reduction in post disaster losses and recovery time.

Arlikatti, Sudha S

2006-08-01T23:59:59.000Z

332

Residence time distribution and coherence resonance of optical-feedback-induced polarization mode hopping in vertical-cavity surface-emitting lasers  

SciTech Connect

We report on an experimental and theoretical investigation of the residence time distribution (RTD) of the polarization mode-hopping regime in vertical-cavity surface-emitting lasers (VCSELs) subject to optical feedback. The RTD exhibits discontinuity and oscillations, as a result of the fast intensity oscillations at the delay time that accompany the slow mode hopping. We furthermore show numerically that an external noise source on the injection current allows observation of a coherence resonance phenomenon in VCSELs induced by time-delayed feedback.

Panajotov, K.; Tabaka, A.; Thienpont, H.; Veretennicoff, I. [Department of Applied Physics and Photonics (TW-TONA), Vrije Universiteit Brussel (VUB), B-1050 Brussels (Belgium); Sciamanna, M.; Megret, P.; Blondel, M. [Service d'Electromagnetisme et de Telecommunications, Faculte Polytechnique de Mons (FPMs), Boulevard Dolez 31, B-7000 Mons (Belgium); Giacomelli, G. [Istituto Nazionale di Ottica Applicata, Largo Enrico Fermi 6, 50125 Firenze (Italy); Istituto Nazionale di Fisica della Materia, Unita di Firenze, Florence (Italy); Marin, F. [Istituto Nazionale di Fisica della Materia, Unita di Firenze, Florence (Italy); Dipartimento di Fisica, Universita di Firenze and LENS, Via Sansone 1, 50019 Sesto Fiorentino, FI (Italy)

2004-01-01T23:59:59.000Z

333

Detailed Analysis of the Thermal Mass Credits in a Code-Traceable DOE-2 Simulation of the 2001 IECC for a Single-Family Residence in Texas  

E-Print Network (OSTI)

This paper presents the results of a study that investigates the thermal mass credits in the 2001 International Energy Conservation Code (IECC) (ICC 1999, 2001) for a single-family residence in Texas using the DOE-2 building energy simulation program. In this analysis seven different wall types were simulated, and each wall type was matched to the recommended overall U-value of a lightweight wall that meets the prescriptive specifications of the 2001 IECC. This paper presents an analysis of the total annual cooling and heating energy use for wall types with varying thermal mass, and thermostat settings, as well as recommendations concerning the most energy-efficient wall type, and includes input specification methods using the DOE-2 program

Kim, S.; Haberl, J.

2008-12-01T23:59:59.000Z

334

Non-OPEC supply to test OPEC`s quota resolve in second half  

SciTech Connect

The paper discusses the oil market, the worldwide outlook for demand, crude oil prices, petroleum product prices, natural gas prices, US outlook, US energy demand, sector demand, US natural gas consumption, US petroleum demand, motor gasoline, distillates, resid, LPG and other products, US petroleum supply, refining, imports, stocks, and Strategic Petroleum Reserve stocks.

Beck, R.J.

1997-07-28T23:59:59.000Z

335

Liquefied Petroleum Gas (LPG) storage facility study Fort Gordon, Georgia. Final report  

SciTech Connect

Fort Gordon currently purchases natural gas from Atlanta Gas Light Company under a rate schedule for Large Commercial Interruptible Service. This offers a very favorable rate for `interruptible` gas service, however, Fort Gordon must maintain a base level of `firm gas`, purchased at a significantly higher cost, to assure adequate natural gas supplies during periods of curtailment to support family housing requirements and other single fuel users. It is desirable to provide a standby fuel source to meet the needs of family housing and other single fuel users and eliminate the extra costs for the firm gas commitment to Atlanta Gas Light Company. Therefore, a propane-air standby fuel system is proposed to be installed at Fort Gordon.

NONE

1992-09-01T23:59:59.000Z

336

Estimating household fuel oil/kerosine, natural gas, and LPG prices by census region  

SciTech Connect

The purpose of this research is to estimate individual fuel prices within the residential sector. The data from four US Department of Energy, Energy Information Administration, residential energy consumption surveys were used to estimate the models. For a number of important fuel types - fuel oil, natural gas, and liquefied petroleum gas - the estimation presents a problem because these fuels are not used by all households. Estimates obtained by using only data in which observed fuel prices are present would be biased. A correction for this self-selection bias is needed for estimating prices of these fuels. A literature search identified no past studies on application of the selectivity model for estimating prices of residential fuel oil/kerosine, natural gas, and liquefied petroleum gas. This report describes selectivity models that utilize the Dubin/McFadden correction method for estimating prices of residential fuel oil/kerosine, natural gas, and liquefied petroleum gas in the Northeast, Midwest, South, and West census regions. Statistically significant explanatory variables are identified and discussed in each of the models. This new application of the selectivity model should be of interest to energy policy makers, researchers, and academicians.

Poyer, D.A.; Teotia, A.P.S.

1994-08-01T23:59:59.000Z

337

Table 4. LPG Consumption and Expenditures in U.S. Households by ...  

U.S. Energy Information Administration (EIA)

Notes: To obtain the RSE percentage for any table cell, multiply the corresponding column and row factors. Because of rounding, data may not sum to totals.

338

Adhesion Force Control and Active Gravitational Compensation for Autonomous Inspection in LPG Storage Spheres  

Science Conference Proceedings (OSTI)

This paper presents a climbing robot based in wheel locomotion and magnetic adherence, a common mechanical topology applicable to a wide range of industrial tasks. The robot is applied to perform internal/external inspection in liquefied petroleum gas ... Keywords: climbing robot, adherence, storage spheres, dynamic control

Andre Schneider de Oliveira; Lucia Valeria Ramos de Arruda; Flavio Neves Jr.; Rodrigo Valerio Espinoza; Joao Pedro Battistella Nadas

2012-10-01T23:59:59.000Z

339

Individual Radiological Protection Monitoring of Utrok Atoll Residents Based on Whole Body Counting of Cesium-137 (137Cs) and Plutonium Bioassay  

SciTech Connect

This report contains individual radiological protection surveillance data developed during 2006 for adult members of a select group of families living on Utrok Atoll. These Group I volunteers all underwent a whole-body count to determine levels of internally deposited cesium-137 ({sup 137}Cs) and supplied a bioassay sample for analysis of plutonium isotopes. Measurement data were obtained and the results compared with an equivalent set of measurement data for {sup 137}Cs and plutonium isotopes from a second group of adult volunteers (Group II) who were long-term residents of Utrok Atoll. For the purposes of this comparison, Group II volunteers were considered representative of the general population on Utrok Atoll. The general aim of the study was to determine residual systemic burdens of fallout radionuclides in each volunteer group, develop data in response to addressing some specific concerns about the preferential uptake and potential health consequences of residual fallout radionuclides in Group I volunteers, and generally provide some perspective on the significance of radiation doses delivered to volunteers (and the general Utrok Atoll resident population) in terms of radiological protection standards and health risks. Based on dose estimates from measurements of internally deposited {sup 137}Cs and plutonium isotopes, the data and information developed in this report clearly show that neither volunteer group has acquired levels of internally deposited fallout radionuclides specific to nuclear weapons testing in the Marshall Islands that are likely to have any consequence on human health. Moreover, the dose estimates are well below radiological protection standards as prescribed by U.S. regulators and international agencies, and are very small when compared to doses from natural sources of radiation in the Marshall Islands and the threshold where radiation health effects could be either medically diagnosed in an individual or epidemiologically discerned in a group of people. In general, the results from the whole-body counting measurements of 137Cs are consistent with our knowledge that a key pathway for exposure to residual fallout contamination on Utrok Atoll is low-level chronic uptake of {sup 137}Cs from the consumption of locally grown produce (Robison et al., 1999). The error-weighted, average body burden of {sup 137}Cs measured in Group I and Group II volunteers was 0.31 kBq and 0.62 kBq, respectively. The associated average, annual committed effective dose equivalent (CEDE) delivered to Group I and Group II volunteers from {sup 137}Cs during the year of measurement was 2.1 and 4.0 mrem. For comparative purposes, the annual dose limit for members of the public as recommended by the National Council on Radiation Protection and Measurements (NCRP) and the International Commission on Radiological Protection (ICRP) is 100 mrem. Consequently, specific concerns about elevated levels of {sup 137}Cs uptake and higher risks from radiation exposure to Group I volunteers would be considered unfounded. Moreover, the urinary excretion of plutonium-239 ({sup 239}Pu) from Group I and Group II volunteers is statistically indistinguishable. In this case, the error-weighted, average urinary excretion of {sup 239}Pu from Group I volunteers of 0.10 {mu}Bq per 24-h void with a range between -0.01 and 0.23 {mu}Bq per 24-h void compares with an error-weighted average from Group II volunteers of 0.11 {mu}Bq per 24-h void with a range between -0.20 and 0.47 {mu}Bq per 24-h void. The range in urinary excretion of {sup 239}Pu from Utrok Atoll residents is very similar to that observed for other population groups in the Marshall Islands (Bogen et al., 2006; Hamilton et al., 2006a; 2006b; 2006c, 2007a; 2007b; 2007c) and is generally considered representative of worldwide background.

Hamilton, T; Kehl, S; Brown, T; Martinelli, R; Hickman, D; Jue, T; Tumey, S; Langston, R

2007-06-08T23:59:59.000Z

340

The Chief Resident Role in Emergency Medicine Residency Programs  

E-Print Network (OSTI)

in an extramural training program, and those CRs whorespondents. Extramural training programs for incoming CRsis an integral part of most training programs throughout the

Hafner, John W.; Gardner, Joanna C; Boston, William S; Aldag, Jean C

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

William A. Sax Title: Executive-in-Residence Residence  

E-Print Network (OSTI)

divided between international and domestic U.S. Direct involvement with oil and gas exploration in U, Netherlands and London, England). · Managed operations and exploration, which discovered and developed oil Entrepreneurship Program). The program started in 1991. #12;2 1955 - 1986: Unocal Corporation · Oil career equally

Ferrari, Silvia

342

Predation by Resident Fish on Juvenile Salmonids in John Day Reservoir: Final Report, 1983-1986: Volume 2: Supplemental Papers and Data Documentation.  

SciTech Connect

In 1982 the NPPC included in its Fish and Wildlife Program measure that called for studies ''... to investigate juvenile salmon and steelhead losses to predators while these fish are migrating through Columbia and Snake River reservoirs.'' In the same year the Bonneville Power Administration (BPA) funded ODFW and FWS to conduct collaborative studies to estimate the number of juvenile salmoids lost to predators in John Day Reservoir. Also included as study objectives were: (1) a description of the importance of predation losses relative to mortality at the dam and total reservoir mortality; (2) a description of how predation losses might vary (spatially and temporally); and (3) recommendations of measures to control predation on smolts. We studied four species of predator; northern squawfish, walleye, smallmouth bass, and channel catfish. We selected John Day Reservoir as the study site because the following factors led us to believe if predation was a problem in any reservoir, it would be most obvious there because: (1) the reservoir is an important subyearling chinook rearing area; (2) passage and residualism of juvenile salmonids were considered a problem there; and (3) substantial populations of predators were known to reside in the reservoir. Individual reports were processed separately for the data base.

Poe, Thomas P.; Rieman, Bruce E.

1988-07-01T23:59:59.000Z

343

Predation by Resident Fish on Juvenile Salmonids in John Day Reservoir: Final Report, 1983-1986: Volume 1, Final Report of Research.  

SciTech Connect

In 1982 the NPPC included in its Fish and Wildlife Program a measure that called for studies ''... to investigate juvenile salmon and steelhead losses to predators while these fish are migrating through Columbia and Snake River reservoirs.'' In the same year the Bonneville Power Administration (BPA) funded ODFW and FWS to conduct collaborative studies to estimate the number of juvenile salmonids lost to predators in John Day Reservoir. Also included as study objectives were: (1) a description of the importance of predation losses relative to mortality at the dam and total reservoir mortality; (2) a description of how predation losses might vary (spatially and temporally); and (3) recommendations of measures to control predation on smolts. We studied four species of predator: northern squawfish, walleye, smallmouth bass, and channel catfish. We selected John Day Reservoir as the study site because the following factors led us to believe if predation was a problem in any reservoir, it would be most obvious there because: (1) the reservoir is an important subyearling chinook rearing area; (2) passage and residualism of juvenile salmonids were considered a problem there; and (3) substantial populations of predators were known to reside in the reservoir. Individual reports were processed separately for the data base.

Poe, Thomas P.; Rieman, Bruce E.

1988-07-01T23:59:59.000Z

344

Test for Modeling Windows in DOE 2.1E for Comparing the Window Library with the Shading Coefficient Method for a Single-Family Residence in Texas  

E-Print Network (OSTI)

This study examines the difference of the window simulation test between the Shading Coefficient (SC) and the Window Library (WL) Methods on DOE 2.1E of the 2000 IECC (International Energy Conservation Code) for single-family residences in Texas. The window simulation tests are performed using single-pane, double-pane, and low-e glass on two standard DOE 2.1E single-family house models: 1) the model which has the R-value for wall, roof and floor according to 2000 IECC (Quick Wall), and 2) the model which has the real wood frame wall and has the same R-value as the first one (Thermal Wall). The analysis showed different results according to the types of the glass, simulation method (Shading Coefficient or Window Library), and types of wall (quick wall and thermal wall). The saving of daily peak heating (kBtu/day) from single-pane to low-e glass on thermal mass and quick wall shows the most variation.

Kim, S.; Haberl, J. S.

2008-07-18T23:59:59.000Z

345

Orientation for New Residents and  

E-Print Network (OSTI)

of implementation is suitable for a system running on event­driven foundation classes, such as MFC and JFC. 3 Aspect that increments the in and out counters defined in the cluster. Let B be a Boolean expression (called a guard procedure within the monitor. One condition vari­ able is declared for each guard B in an await statement

Squire, Jeremy

346

Traditional Residence Halls Residential Colleges  

E-Print Network (OSTI)

,885 Annie Boyd Hall 2-student, suite bath $3,365 2-student, private bath $3,365 Beauregard Hall 2-student

Harms, Kyle E.

347

Hot Water Electric Energy Use in Single-Family Residences in the Pacific Northwest : Regional End-Use Metering Project (REMP).  

SciTech Connect

The Office of Energy Resources of the Bonneville Power Administration carriers out generation and conservation resource planning. The analysis of historical trends in and determinants of energy consumption is carried out by the office's End-Use Research Section. The End-Use Research Section operates a comprehensive data collection program to provide pertinent information to support demand-side conservation planning, load forecasting, and conservation program development and delivery. Part of this on-going program, commonly known as the End-Use Load and Consumer Assessment Program (ELCAP), was recently renamed the Regional End-Use Metering Project (REMP) to reflect an emphasis on metering rather than analytical activities. REMP is designed to collect electricity usage data through direct monitoring of end-use loads in buildings in the residential and commercial sectors and is conducted for Bonneville by Pacific Northwest Laboratories (Battelle). The detailed summary information in this report is on energy used for water heaters in the residential sector and is based on data collected from September 1985 through December 1990 for 336 of the 499 REMP metered homes. Specific information is provided on annual loads averaged over the years and their variation across residences. Descriptions are given of use as associated with demographic and energy-related characteristics. Summaries are also provided for electricity use by each year, month, and daytype, as well as at peak hot water load and peak system times. This is the second residential report. This report focuses on a specific end use and adds detail to the first report. Subsequent reports are planned on other individual end uses or sets of end uses. 15 refs., 29 figs., 10 tabs.

Taylor, Megan E., Ritland, Keith G., Pratt, R.G.

1991-09-01T23:59:59.000Z

348

Increased Levels of Harvest and Habitat Law Enforcement and Public Awareness for Anadromous Salmonids and Resident Fish in the Columbia River Basin -- Demonstration Period, 1992--1994, Final Report.  

DOE Green Energy (OSTI)

This report was funded by the Bonneville Power Administration (BPA), US Department of Energy, as part of BPA`s program to protect, mitigate, and enhance fish and wildlife affected by the development and operation of hydroelectric facilities on the Columbia River and its tributaries. Illegal harvest and violation of habitat protection regulations are factors affecting the survival of many native species of anadromous and resident fish in the Columbia Basin.

NeSmith, Frank (Idaho Department of Fish and Game, Boise, ID); Long, Mack (Montana Department of Fish, Wildlife and Paks, Kalispell, MT); Matthews, Dayne (Washington Department of Fish and Wildlife, Olympia, WA)

1995-06-01T23:59:59.000Z

349

Work to save dose: contrasting effective dose rates from radon exposure in workplaces and residences against the backdrop of public and occupational limits  

Science Conference Proceedings (OSTI)

Office workers are exposed to radon while at work and at home. Though there has been a multitude of studies reporting the measurements of radon concentrations and potential lung and effective doses associated with radon and progeny exposure in homes, similar studies on the concentrations and subsequent effective dose rates in the non-mine workplaces are lacking. Additionally, there are few, if any, comparative analyses of radon exposures at more 'typical' workplace with residential exposures within the same county. The purposes of this study were to measure radon concentrations in office and residential spaces in the same county and explore the radiation dose implications. Sixty-five track-etch detectors were deployed in office spaces and 47 were deployed in residences, all within Los Alamos County, New Mexico, USA. The sampling periods for these measurements were generally about three months. The measured concentrations were used to calculate and compare effective dose rates resulting from exposure while at work and at home. Results showed that full-time office workers receive on average about 8 times greater exposure at home than while in the office (2.3 mSv yr-! versus 0.3 mSv yr-!). The estimated effective dose rate for a more homebound person was about 3 mSv yr-!. Estimating effective doses from background radon exposure in the same county as Los Alamos National Laboratory, with thousands of'radiological workers,' highlights interesting contrasts in radiation protection standards that span public and occupational settings. For example, the effective dose rate from background radon exposure in unregulated office spaces ranged up to 1.1 mSv yr-!, which is similar to the 1 mSv yr-! threshold for regulation ofa 'radiological worker,' as defined in the Department of Energy regulations for occupational exposure. Additionally, the estimated average effective dose total of> 3 mSv yf! from radon background exposure in homes stands in contrast to the 0.1 mSv yr-! air pathway effective public dose limit regulated by the Environmental Protection Agency for radioactive air emissions.

Whicker, Jeffrey J [Los Alamos National Laboratory; Mcnaughton, Michael W [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

350

A Multiple Watershed Approach to Assessing the Effects of Habitat Restoration Actions on Anadromous and Resident Fish Populations, Technical Report 2003-2004.  

DOE Green Energy (OSTI)

Habitat protection and restoration is a cornerstone of current strategies to restore ecosystems, recover endangered fish species, and rebuild fish stocks within the Columbia River Basin. Strategies featuring habitat restoration include the 2000 Biological Opinion on operation of the Federal Columbia River Power System (FCRPS BiOp) developed by the National Marine Fisheries Service (NMFS), the 2000 Biological Opinion on Bull Trout developed by the US Fish and Wildlife Service (USFWS), and Sub-Basin Plans developed under the Fish and Wildlife Program of the Northwest Power and Conservation Council (NWPCC). There is however little quantitative information about the effectiveness of different habitat restoration techniques. Such information is crucial for helping scientists and program managers allocate limited funds towards the greatest benefits for fish populations. Therefore, it is critical to systematically test the hypotheses underlying habitat restoration actions for both anadromous and resident fish populations. This pilot project was developed through a proposal to the Innovative Projects fund of the NWPCC (ESSA 2002). It was funded by the Bonneville Power Administration (BPA) following reviews by the Independent Scientific Review Panel (ISRP 2002), the Columbia Basin Fish and Wildlife Authority (CBFWA 2002), the NWPCC and BPA. The study was designed to respond directly to the above described needs for information on the effectiveness of habitat restoration actions, including legal measures specified in the 2000 FCRPS BiOp (RPA 183, pg. 9-133, NMFS 2000). Due to the urgency of addressing these measures, the timeline of the project was accelerated from a duration of 18 months to 14 months. The purpose of this pilot project was to explore methods for evaluating past habitat restoration actions and their effects on fish populations. By doing so, the project will provide a foundation of retrospective analyses, on which to build prospective, multi-watershed designs for future habitat restoration actions. Such designs are being developed concurrently with this project by several other groups in the Columbia Basin (RME Workgroup 2003, NMFS 2003, Hillman and Paulsen 2002, Hillman 2003). By addressing questions about habitat restoration and monitoring (in coordination with other related efforts), we hope that this project will catalyze a shift in the Basin's paradigm of habitat restoration, moving from implementation of individual watershed projects towards rigorously designed and monitored, multiwatershed, adaptive management experiments. The project involved three phases of work, which were closely integrated with various related and ongoing efforts in the region: (1) Scoping - We met with a Core Group of habitat experts and managers to scope out a set of testable habitat restoration hypotheses, identify candidate watersheds and recommend participants for a data evaluation workshop. (2) Data Assembly - We contacted over 80 scientists and managers to help evaluate the suitability of each candidate watershed's historical data for assessing the effectiveness of past restoration actions. We eventually settled on the Yakima, Wenatchee, Clearwater, and Salmon subbasins, and began gathering relevant data for these watersheds at a workshop with habitat experts and managers. Data assembly continued for several months after the workshop. (3) Data Analysis and Synthesis - We explored statistical approaches towards retrospectively analyzing the effects of restoration 'treatments' at nested spatial scales across multiple watersheds (Chapters 2-5 of this report). These analyses provided a foundation for identifying existing constraints to testing restoration hypotheses, and opportunities to overcome these constraints through improved experimental designs, monitoring protocols and project selection strategies (Chapters 6 and 7 of this report). Finally, we developed a set of recommendations to improve the design, implementation, and monitoring of prospective habitat restoration programs in the Columbia River Basin (Chapter 8).

Marmorek, David

2004-03-01T23:59:59.000Z

351

A Multi-Country Analysis of Lifecycle Emissions From Transportation Fuels and Motor Vehicles  

E-Print Network (OSTI)

hydrogen, LPG = liquefied petroleum gases. 1) The gasolinegas; LPG = liquefied petroleum gases; cell. = cellulosic; EV177 Other petroleum fuel sulfur

Delucchi, Mark

2005-01-01T23:59:59.000Z

352

A MULTI-COUNTRY ANALYSIS OF LIFECYCLE EMISSIONS FROM TRANSPORTATION FUELS AND MOTOR VEHICLES  

E-Print Network (OSTI)

hydrogen, LPG = liquefied petroleum gases. 1) The gasolinegas; LPG = liquefied petroleum gases; cell. = cellulosic; EV177 Other petroleum fuel sulfur

Delucchi, Mark

2005-01-01T23:59:59.000Z

353

Refinery Waste Heat Ammonia Absorption Refrigeration Plant (WHAARP) Recovers LPG's and Gasoline, Saves Energy, and Reduces Air Pollution  

E-Print Network (OSTI)

A first-of-its-kind Waste Heat Ammonia Absorption Refrigeration Plant (WHAARP) was installed by Planetec Utility Services Co., Inc. in partnership with Energy Concepts Co. at Ultramar Diamond Shamrock's 30,000 barrel per day refinery in Denver, Colorado. The refrigeration unit is designed to provide refrigeration for two process units at the refinery while utilizing waste heat as the energy source. The added refrigeration capacity benefits the refinery by recovering salable products, debottlenecking process units, avoiding additional electrical demand, and reducing the refinery Energy Intensity Index. In addition, the WHAARP unit lowers air pollutant emissions by reducing excess fuel gas that is combusted in the refinery flare. A comprehensive utility and process efficiency Master Plan developed for the Denver refinery by Planetec provided the necessary platform for implementing this distinctive project. The $2.3 million WHAARP system was paid for in part by a $760,000 grant from the U.S. Department of Energy, as part of their "Industry of the Future Program". Total combined benefits are projected to be approximately $1 million/year with a 1.6 year simple payback including the grant funding.

Brant, B.; Brueske, S.; Erickson, D.; Papar, R.

1998-04-01T23:59:59.000Z

354

Model curriculum outline for Alternatively Fueled Vehicle (AFV) automotive technician training in light and medium duty CNG and LPG  

DOE Green Energy (OSTI)

This model curriculum outline was developed using a turbo-DACUM (Developing a Curriculum) process which utilizes practicing experts to undertake a comprehensive job and task analysis. The job and task analysis serves to establish current baseline data accurately and to improve both the process and the product of the job through constant and continuous improvement of training. The DACUM process is based on the following assumptions: (1) Expert workers are the best source for task analysis. (2) Any occupation can be described effectively in terms of tasks. (3) All tasks imply knowledge, skills, and attitudes/values. A DACUM panel, comprised of six experienced and knowledgeable technicians who are presently working in the field, was given an orientation to the DACUM process. The panel then identified, verified, and sequenced all the necessary job duty areas and tasks. The broad duty categories were rated according to relative importance and assigned percentage ratings in priority order. The panel then rated every task for each of the duties on a scale of 1 to 3. A rating of 3 indicates an {open_quotes}essential{close_quotes} task, a rating of 2 indicates an {open_quotes}important{close_quotes} task, and a rating of 1 indicates a {open_quotes}desirable{close_quotes} task.

NONE

1997-04-01T23:59:59.000Z

355

Design and Analysis of Salmonid Tagging Studies in the Columbia Basin : Evaluating Wetland Restoration Projects in the Columbia River Estuary using Hydroacoustic Telemetry Arrays to Estimate Movement, Survival, and Residence Times of Juvenile Salmonids, Volume XXII (22).  

DOE Green Energy (OSTI)

Wetlands in the Columbia River estuary are actively being restored by reconnecting these habitats to the estuary, making more wetland habitats available to rearing and migrating juvenile salmon. Concurrently, thousands of acoustically tagged juvenile salmonids are released into the Columbia River to estimate their survival as they migrate through the estuary. Here, we develop a release-recapture model that makes use of these tagged fish to measure the success of wetland restoration projects in terms of their contribution to populations of juvenile salmon. Specifically, our model estimates the fraction of the population that enter the wetland, survival within the wetland, and the mean residence time of fish within the wetland. Furthermore, survival in mainstem Columbia River downstream of the wetland can be compared between fish that remained the mainstem and entered the wetland. These conditional survival estimates provide a means of testing whether the wetland improves the subsequent survival of juvenile salmon by fostering growth or improving their condition. Implementing such a study requires little additional cost because it takes advantage of fish already released to estimate survival through the estuary. Thus, such a study extracts the maximum information at minimum cost from research projects that typically cost millions of dollars annually.

Perry, Russell W.; Skalski, John R.

2008-08-01T23:59:59.000Z

356

Better Buildings Neighborhood Program: Northern Virginia Residents...  

NLE Websites -- All DOE Office Websites (Extended Search)

Makeover Contest logo. The Local Energy Alliance Program (LEAP) awarded energy efficiency funding to three households as part of the program's Northern Virginia Home Energy...

357

Gulf Coast Residents Underestimate Hurricane Destructive Potential  

Science Conference Proceedings (OSTI)

Most people do not realize that hurricane destructiveness increases nonlinearly with increases in storm intensity. Three studies were conducted to examine peoples perceptions of hurricane destructive potential and their likelihood of evacuation. ...

Alan E. Stewart

2011-04-01T23:59:59.000Z

358

Eighteen Local Residents Receive High Honors from ...  

Science Conference Proceedings (OSTI)

... Using teamwork and private-sector partnering, the team built the US Business Development Committees with Russia, Ukraine and Kazakhstan. ...

2012-12-13T23:59:59.000Z

359

User evaluation study of passive solar residences  

SciTech Connect

Speculation exists regarding the readiness of various passive techniques for commercialization and the market potential for residential applications. This paper discusses the preliminary findings of a market assessment study designed to document user experiences with passive solar energy. Owners and builders of passive solar homes were interviewed and asked to comment on personal experiences with their homes.

Towle, S.

1980-03-01T23:59:59.000Z

360

Residents and windows. 1. Shielding of windows  

SciTech Connect

In order to assess the influence of the shielding of windows performed by occupants in residential buildings on the heat balance of the building, the shielding of 40,000 windows was determined by observation during two heating seasons. It is shown that the demand for privacy has a large effect on the degree of window-shielding. There are also indications that many occupants trying to save energy use window-shielding as one of their means to achieve this.

Lyrberg, M.D.

1983-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Kalispel Resident Fish Project : Annual Report, 2002.  

DOE Green Energy (OSTI)

In 2002 the Kalispel Natural Resource Department (KNRD) continued monitoring enhancement projects (implemented from 1996 to 1998) for bull trout (Salvelinus confluentus), westslope cutthroat (Oncorhynchus clarki lewisi) and largemouth bass (Micropterus salmoides). Additional baseline fish population and habitat assessments were conducted, in 2002, in tributaries to the Pend Oreille River. Further habitat and fish population enhancement projects were also implemented in 2002.

Andersen, Todd; Olson, Jason

2003-03-01T23:59:59.000Z

362

108 Local Residents Earn Commerce Department, NIST ...  

Science Conference Proceedings (OSTI)

... Administrative Assistant; Ellen Y. Emard, Information Specialist; Anne H. Meininger, Technical Information Specialist; Han Thai, Web Programmer ...

2010-10-05T23:59:59.000Z

363

Residences (R) R1 The University Village  

E-Print Network (OSTI)

Thomas Paine Study Centre P7 C15 C19 P Nursery drop off P8 ENTRANCE / EXIT BIOMASS KEY Footpath, Café Direct Coffee Shop C12 Union House: Travel Shop, The Hive/LCR, EmployAbility Job Shop, Student

Matthews, Adrian

364

Residences (R) R1 University Village  

E-Print Network (OSTI)

off P8 ENTRANCE / EXIT BIOMASS KEY Footpath/walkway Disabled access Steps Stairway Food outlets Bus House: Travel Shop, The Hive/LCR, EmployAbility Job Shop, Student Union Advice Centre, Union Bars C13

Dixon, Peter

365

Kalispel Resident Fish Project : Annual Report, 1995.  

DOE Green Energy (OSTI)

In 1995 the Kalispel Natural Resource Department (KNRD) in conjunction with the Washington Department of Fish and Wildlife (WDFW) initiated the implementation of a habitat and population enhancement project for bull trout (Salvelinus confluentus), westslope cutthroat trout (Oncorhynchus clarki lewisi) and largemouth bass (Micropterus salmoides). Habitat and population assessments were conducted in seven tributaries of the Box Canyon reach of the Pend Oreille River. Assessments were used to determine the types and quality of habitat that were limiting to native bull trout and cutthroat trout populations. Assessments were also used to determine the effects of interspecific competition within these streams. A bull trout and brook trout (Salvelinus fontinalis) hybridization assessment was conducted to determine the degree of hybridization between these two species. Analysis of the habitat data indicated high rates of sediment and lack of wintering habitat. The factors that contribute to these conditions have the greatest impact on habitat quality for the tributaries of concern. Population data suggested that brook trout have less stringent habitat requirements; therefore, they have the potential to outcompete the native salmonids in areas of lower quality habitat. No hybrids were found among the samples, which is most likely attributable to the limited number of bull trout. Data collected from these assessments were compiled to develop recommendations for enhancement measures. Recommendations for restoration include riparian planting and fencing, instream structures, as well as, removal of non-native brook trout to reduce interspecific competition with native salmonids in an isolated reach of Cee Cee Ah Creek.

Maroney, Joseph; Donley, Christopher; Scott, Jason; Lockwood, Jr., Neil

1997-06-01T23:59:59.000Z

366

Eleven Local Residents Receive High Honors from ...  

Science Conference Proceedings (OSTI)

... ranging from solidification of superalloy turbine blades to solder ... Richard HF Jackson, Director, Manufacturing Engineering Laboratory "For his ...

2010-10-05T23:59:59.000Z

367

2010-2011 Pediatric Residents Christy Mumphrey  

E-Print Network (OSTI)

Guadalajara Michael Blancaneaux LSUHSC-NO Catherine Durst Kansas City University of Medicine and Biosciences

368

Local Residents Honored with NIST Crittenden Awards  

Science Conference Proceedings (OSTI)

... of NIST's accounting system that has played a key role in the agency receiving unqualified audit opinions for its annual financial statement audits. ...

2013-07-19T23:59:59.000Z

369

MORNINGSIDE An informational newsletter for residents  

E-Print Network (OSTI)

residential buildings on the Morningside campus to using natural gas as the primary fuel source for heat delivery trucks--will cut the University's greenhouse gas emissions and result in a more efficient heating of these buildings the boilers will be converted or replaced so that they can operate on natu- ral gas; the gas

Qian, Ning

370

Kalispel Resident Fish Project : Annual Report, 2008.  

DOE Green Energy (OSTI)

In 2008, the Kalispel Natural Resource Department (KNRD) continued to implement its habitat enhancement projects for bull trout (Salvelinus confluentus) and westslope cutthroat trout (Oncorhynchus clarki lewisi). Baseline fish population and habitat assessments were conducted in Upper West Branch Priest River. Additional fish and habitat data were collected for the Granite Creek Watershed Assessment, a cooperative project between KNRD and the U.S. Forest Service Panhandle National Forest (FS) . The watershed assessment, funded primarily by the Salmon Recovery Funding Board of the State of Washington, will be completed in 2009.

Andersen, Todd [Kalispel Natural Resource Department

2009-07-08T23:59:59.000Z

371

Emissions of Criteria Pollutants, Toxic Air Pollutants, and Greenhouse Gases, From the Use of Alternative Transportation Modes and Fuels  

E-Print Network (OSTI)

gasoline, methanol, ethanol, CNG, and LPG vehicles, Januaryemissions-profile data base for CNG, and LPG vehicles, MarchCarpool or vanpool? gasoline CNG car n.a. no LPG CNG van LRT

Delucchi, Mark

1996-01-01T23:59:59.000Z

372

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network (OSTI)

Central Air, Fuels = Oil and Gas, Other = LPG and Misc. (3)Central Air, Fuels = Oil and Gas, LPG and Misc. (3) Sources:Central Air, Fuels = Oil and Gas, Other = LPG and Misc. (3)

Johnson, F.X.

2010-01-01T23:59:59.000Z

373

Energy Data Sourcebook for the U.S. Residential Sector  

E-Print Network (OSTI)

South Gas LPG Oil Electricity Source: US DOE 1995 forLPG -- FRN RM - Oil - OTH Other Source: US DOE 1995b. OilLPG H20 FRN - Oil RM OTH Other Source: US DOE 1995b. Oil

Wenzel, T.P.

2010-01-01T23:59:59.000Z

374

Life-Cycle Water Impacts of U.S. Transportation Fuels  

E-Print Network (OSTI)

to approximate propane, butane, and LPG purchases, and U.S.Groundwater (MJ/L) Electricity NG Propane/ Butane/LPG DieselElectricity NG Propane/ Butane/ LPG Diesel AL 2.1E-05 N/A N/

Scown, Corinne Donahue

2010-01-01T23:59:59.000Z

375

A Multi-Country Analysis of Lifecycle Emissions From Transportation Fuels and Motor Vehicles  

E-Print Network (OSTI)

CNG ICEV, LPG ICEV, corn ethanol ICEV, cell. ethanol BatteryCNG ICEV, LPG ICEV, corn ethanol ICEV, cell. ethanol BatteryCNG ICEV, LPG ICEV, corn ethanol ICEV, cell. ethanol Battery

Delucchi, Mark

2005-01-01T23:59:59.000Z

376

A MULTI-COUNTRY ANALYSIS OF LIFECYCLE EMISSIONS FROM TRANSPORTATION FUELS AND MOTOR VEHICLES  

E-Print Network (OSTI)

CNG ICEV, LPG ICEV, corn ethanol ICEV, cell. ethanol BatteryCNG ICEV, LPG ICEV, corn ethanol ICEV, cell. ethanol BatteryCNG ICEV, LPG ICEV, corn ethanol ICEV, cell. ethanol Battery

Delucchi, Mark

2005-01-01T23:59:59.000Z

377

China's Industrial Carbon Dioxide Emissions in Manufacturing Subsectors and in Selected Provinces  

E-Print Network (OSTI)

Oil LPG Refinery Gas Other Petroleum Products Natural GasOil LPG Refinery Gas Other Petroleum Products Natural GasEquipment Chemicals Food Petroleum & Coking Textiles Paper

Lu, Hongyou

2013-01-01T23:59:59.000Z

378

Texas Bi-Fuel Liquefied Petroleum Gas Pickup Study: Final Report  

NLE Websites -- All DOE Office Websites (Extended Search)

represent selected fuel economy data.) ...11 Figure 4. Monthly purchase prices of gasoline and LPG (Note: the price of LPG was higher in the Corpus district than...

379

Home Energy Saver  

NLE Websites -- All DOE Office Websites (Extended Search)

Heater Heat Pumps Replacing Your Electric Furnace and CAC with a Heat Pump Sealing Home Air Leaks LPG Furnaces Efficient LPG-fired Water Heaters Oil Furnaces Efficient...

380

Detailed Analysis of Thermal Mass Effects in a Code-Traceable DOE-2 Simulation of the 2000 IECC for a Single-Family Residence in Texas: A Project for Texas' Senate Bill 5 Legislation for Reducing Pollution in Nonattainment and Affected Areas  

E-Print Network (OSTI)

This study examines the thermal mass effects in a code-traceable DOE-2 simulation of the 2000 IECC (International Energy Conservation Code) for a single-family residence in Texas. This report is composed of two major simulations: 1) the simulation according to the location of the insulation of IECC2000, and 2) the simulation according to the types of real brick and block walls which are practically used at the residential house. In this study, the 2000 IECC was used to develop the base case simulation model in Houston, Texas. The DOE-2 energy simulation program was used to analyze changes to the annual energy use caused by changing various building materials. The best energy conservative material layout was then chosen that contained reduced annual energy use, peak cooling and heating loads, and peak day electricity use.

Kim, S.; Haberl, J. S.

2008-07-18T23:59:59.000Z

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Patient Perceptions of Resident Interpersonal and Communication Skills in the Emergency Department; An Analysis by Post-Graduate Year of Emergency Medicine Residents and Off-Service Residents  

E-Print Network (OSTI)

interns, regardless of training program, to have better ICSdiffer between training programs [emergency medicine (EM) v.

2008-01-01T23:59:59.000Z

382

PROPELLED EXTINGUISHING AGENT TECHNOLOGIES ...  

Science Conference Proceedings (OSTI)

... Boiler rooms Armored vehicles (engine compartment) Automotive (LPG /LNG) Navy ships (large engine rooms) Cable tunnels ...

2011-11-01T23:59:59.000Z

383

Photovoltaics Life Cycle Analysis  

E-Print Network (OSTI)

Comparisons of Estimated Maximum Consequences Coal Oil NG LPG Nuclear (Chernobyl) Nuclear (except Chernobyl

384

Classic Template - Blue  

Science Conference Proceedings (OSTI)

... Fire detecting and extinguishing equipment Liquefied Petroleum Gas (LPG) utilization equipment (commercial and industrial) ...

2012-10-30T23:59:59.000Z

385

The Bumpy Road to Hydrogen  

E-Print Network (OSTI)

gases (LPG) and compressed natural gas (CNG) have persistedbenefits from compressed natural gas, ethanol, methanol,

Sperling, Dan; Ogden, Joan M

2006-01-01T23:59:59.000Z

386

A Multi-Country Analysis of Lifecycle Emissions From Transportation Fuels and Motor Vehicles  

E-Print Network (OSTI)

n.a. n.a. n.a. n.a. n.a. Coke oil n.a. n.a. n.a. n.a. n.a.CG RFG Diesel FTD Fuel oil Stillgas Coke LPG LPG CNG NuclearFTD NG Fuel oil Still gas Coke oil oil oil LPG oil LPG NGL57

Delucchi, Mark

2005-01-01T23:59:59.000Z

387

A MULTI-COUNTRY ANALYSIS OF LIFECYCLE EMISSIONS FROM TRANSPORTATION FUELS AND MOTOR VEHICLES  

E-Print Network (OSTI)

n.a. n.a. n.a. n.a. n.a. Coke oil n.a. n.a. n.a. n.a. n.a.CG RFG Diesel FTD Fuel oil Stillgas Coke LPG LPG CNG NuclearFTD NG Fuel oil Still gas Coke oil oil oil LPG oil LPG NGL57

Delucchi, Mark

2005-01-01T23:59:59.000Z

388

What are the lighting requirements for residences? | Building...  

NLE Websites -- All DOE Office Websites (Extended Search)

lamps (2009 IECC, Section 404.1). The 2012 IECC has increased the minimum percentage from 50% to 75%, along with an exception for low-voltage lighting (2012 IECC,...

389

GCHP Results in Net-Zero Energy Residence in Japan  

E-Print Network (OSTI)

Gas Water Heater · Lighting Fixtures: LED · Solar Photo-voltaic System: 5.94kW · Home Energy (Q value) · Low-e Windows: · Natural Ventilation System: Ducted · Domestic Hot Water: Instantaneous · Advanced Ambient Light Sensor Control · Lithium Battery Storage System · Solar Thermal Heat Collector: 4m2

390

Motivating Residents to Conserve Energy Without Financial Incentives  

NLE Websites -- All DOE Office Websites (Extended Search)

16, 235-246. Staats, H.J., Wit, A.P., & Midden, C.Y.H. (1996). Communicating the greenhouse effect to the public: Evaluation of a mass media campaign from a social dilemma...

391

Affordable luxury resort residences for the Baby Boomers  

E-Print Network (OSTI)

The purpose of this thesis is to determine the business viability of Oasis Destination Club, the first destination club designed entirely for the upper middle income baby boomer. The baby boomer generation is the largest ...

Boyer, Mark Valdez

2005-01-01T23:59:59.000Z

392

for all Student Housing residents IN A COMMUNITY  

E-Print Network (OSTI)

that research suggests will be most common during the flu season. Vaccination is especially important for people and dressers off the street; steer clear of yard sales or flea markets; never buy used bedding. · If you dry, opening windows and running fans to ventilate areas, letting as much natural light as possible

Hammock, Bruce D.

393

Kentucky Residents Cash in on Rebate Program | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Program September 9, 2010 - 6:30pm Addthis Air-conditioning units are just one of 16 appliances that the Kentucky Appliance Rebate program supports.| File photo Air-conditioning...

394

35 Local Residents Earn NIST Bronze Medal Awards  

Science Conference Proceedings (OSTI)

... creating an international database of measurement ... effective and efficient management systems. ... for maintaining stable environmental conditions in ...

2010-10-05T23:59:59.000Z

395

ENERGY STAR Score for Residence Halls/ Dormitories | ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

Federal agency resources Grocery & convenience stores resources Healthcare resources Higher education resources Home-based business resources Hospitality resources Industrial...

396

Study on TOU Price Implantation Effect on Huainan Resident  

Science Conference Proceedings (OSTI)

Time-of-use (TOU) tariff is an important means toad just the residential electricity consumption behavior and reduce the difference between the peak and valley load. This paper sets up a residential electricity consumption inclination model by extracting ... Keywords: TOU electricity price, Valley quantity coefficient, Peak shifting, valley filling, Electricity costs

Li Mei; Wan Qiulan

2011-02-01T23:59:59.000Z

397

Ultrafine particle concentrations and exposure in seven residences...  

NLE Websites -- All DOE Office Websites (Extended Search)

Unvented natural-gas pilot lights contributed up to 19% to exposure for the two households where present. Episodic indoor source activities, most notably cooking, caused the...

398

VASDHS/UCSD CLINICAL PSYCHOLOGY POSTDOCTORAL RESIDENCY PROGRAM  

E-Print Network (OSTI)

: Anxiety, Geropsychology and Home-based Care, Mood Disorders and Suicidality, OEF/OIF/OND PTSD, and Family

Squire, Larry R.

399

Gardens of an Historic Cowper Street Residence [Speaking of Places  

E-Print Network (OSTI)

were sources of leather, tallow and meat that could be soldleather processed, and tallow made. Much of the romance

Roberts, John N

2005-01-01T23:59:59.000Z

400

Kentucky Residents Cash in on Rebate Program | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and even to solar water heaters and geothermal heat pumps. So far, Kentucky's energy efficient appliance rebate program has issued nearly 29,500 rebates to Kentucky...

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Kootenai River Resident Fish Assessment, FY2008 KTOI Progress Report.  

DOE Green Energy (OSTI)

The overarching goal of project 1994-049-00 is to recover a productive, healthy and biologically diverse Kootenai River ecosystem, with emphasis on native fish species rehabilitation. It is especially designed to aid the recovery of important fish stocks, i.e. white sturgeon, burbot, bull trout, kokanee and several other salmonids important to the Kootenai Tribe of Idaho and regional sport-fisheries. The objectives of the project have been to address factors limiting key fish species within an ecosystem perspective. Major objectives include: establishment of a comprehensive and thorough biomonitoring program, investigate ecosystem--level in-river productivity, test the feasibility of a large-scale Kootenai River nutrient addition experiment (completed), to evaluate and rehabilitate key Kootenai River tributaries important to the health of the lower Kootenai River ecosystem, to provide funding for Canadian implementation of nutrient addition and monitoring in the Kootenai River ecosystem (Kootenay Lake) due to lost system productivity created by construction and operation of Libby Dam, mitigate the cost of monitoring nutrient additions in Arrow Lakes due to lost system productivity created by the Libby-Arrow water swap, provide written summaries of all research and activities of the project, and, hold a yearly workshop to convene with other agencies and institutions to discuss management, research, and monitoring strategies for this project and to provide a forum to coordinate and disseminate data with other projects involved in the Kootenai River basin.

Holderman, Charles

2009-06-26T23:59:59.000Z

402

A Survey of Graduating Emergency Medicine Residents Experience with Cricothyrotomy  

E-Print Network (OSTI)

States anesthesiology training programs. J Clin Anesth. 21.Medicine complete EM training programs in 2011, yielding aoutside their EM training programs. Since cricothyrotomy is

Makowski, Andrew L.

2013-01-01T23:59:59.000Z

403

Rebuttal: Advantages of a Four-Year Residency  

E-Print Network (OSTI)

year primary care training programs. In summary, although wedependent on individual training programs, are of interest3 and 2-4 programs. Only true four- year EM training was

Langdorf, Mark; Lotfipour, Shahram

2004-01-01T23:59:59.000Z

404

Orientationfor New Residents and Fellows at the University of Toronto  

E-Print Network (OSTI)

and ERS1 as marker genes for the ethylene response, PIN1 and IAA19 for the auxin response, MFC19 expressed in the guard cells and affects the stomatal response to ABA: guard cells of the dor mutant SCFDOR activity could result in increased ABA sensitivity in the guard cells, which would in turn explain

Squire, Jeremy

405

Nuclear radiation awareness for residents of Cascade County-Montana.  

E-Print Network (OSTI)

??The potential of a radiation mishap is real and lack of public awareness only potentiates the devastating outcomes on the citizens in the effected area (more)

Strand, Aven Lynn.

2006-01-01T23:59:59.000Z

406

City and County of Denver - Denver Energy Challenge for Residents...  

Open Energy Info (EERE)

(DSIRE)1 Summary The City and County of Denver are providing rebates to Denver homeowners through the Denver Energy Challenge. To be eligible, participants must first sign up...

407

Project Res-IDENT: Qualitative Assessment of Home Networking Appliances  

Science Conference Proceedings (OSTI)

While people appreciate the "money saving" aspects of new household appliances, they are more motivated by the "extra time, less hassle, more comfort, peace of mind" benefits these appliances confer. This study explored consumer interest in home management technologies including an Energy Network Computer (EnergyNC) based on the network computer that would allow customers to manage and monitor their energy use through a wireless keyboard and TV set top box connected to the Internet via standard telephone...

1999-12-10T23:59:59.000Z

408

Commissioning High Performance Residences in Hot, Humid Climates  

E-Print Network (OSTI)

Since 2001, the authors have engaged several builders in the Gainesville, FL area to build over 500 high performance new energy efficient homes in multiple sub divisions. The builders keep building to increased levels of energy efficiency. Each home is individually designed, inspected, rated and commissioned for optimum performance. This paper summarizes the experiences to date with two production builders who have cost shared with the Building America program to deliver these outstanding results. Keys to success are commitment from the final decision maker; scopes of work for subcontractors with specific performance criteria; clear communication with the trades often accompanied by training and education activities; independent third party testing, commissioning and feedback to building; ongoing training of sales staff and model center displays and finally extensive marketing that educated the consumers about the benefits of high performance homes.

Fonorow, K.; Chandra, S.; McIlvaine, J.; Colon, C.

2007-01-01T23:59:59.000Z

409

Duck Valley Resident Fish Stocking Program, 2000 Final Annual Report.  

DOE Green Energy (OSTI)

The Shoshone-Paiute Tribes fish-stocking program was begun in 1988 and is intended to provide a subsistence fishery for the tribal members. The program stocks catchable and fingerling size trout in Mt. View and Sheep Creek Reservoirs. Rainbow trout are purchased from only certified disease-free facilities to be stocked in our reservoirs. This project will help restore a fishery for tribal members that historically depended on wild salmon and steelhead in the Owyhee and Bruneau Rivers and their tributaries for their culture as well as for subsistence. This project is partial substitution for loss of anadromous fish production due to construction and operation of hydroelectric dams on the Columbia and Snake Rivers. Until anadromous fish can be returned to the Owyhee and Bruneau Rivers this project will continue indefinitely. As part of this project the Shoshone-Paiute Tribes will also receive income in the form of fees from non-tribal members who come to fish these reservoirs. Regular monitoring and evaluation of the fishery will include sampling for length/weight/condition and for signs of disease. A detailed Monitoring and evaluation plan has been put in place for this project. However due to budget limitations on this project only the fishery surveys and limited water quality work can be completed. A creel survey was initiated in 1998 and we are following the monitoring and evaluation schedule for this program (as budget allows) as well as managing the budget and personnel. This program has been very successful in the past decade and has provided enjoyment and sustenance for both tribal and non-tribal members. All biological data and stocking rates will be including in the Annual reports to Bonneville Power Administration (BPA).

Dodson, Guy; Pero, Vincent

2002-01-01T23:59:59.000Z

410

Management Training for Pathology Residents: A Regional Approach  

E-Print Network (OSTI)

a didactic management training program for the residentsportion of the management training program described herein 2 other training programs had occa- sional management

Wagar, E A

2004-01-01T23:59:59.000Z

411

Standby power consumption in U.S. residences  

Science Conference Proceedings (OSTI)

{open_quotes}Leaking electricity{close_quotes} is the electricity consumed by appliances while they are switched {open_quotes}off{close_quote} or not performing their principal function. Leaking electricity represents approximately 5 % of U.S. residential electricity. This is a relatively new phenomenon and is a result of proliferation of electronic equipment in homes. The standby losses in TVs, VCRs, compact audio systems, and cable boxes account for almost 40% of all leaking electricity. There is a wide range in standby losses in each appliance group. For example, standby losses in compact audio systems range from 2.1 to 28.6 W, even though their features are identical. In some cases, leaking electricity while switched off was only slightly less than energy consumption in the on mode. New features in these appliances may greatly increase leaking electricity, such as electronic program guides in TVs and cable boxes. In the standby mode, these new features require many extra components energized to permit the downloading of information. Several techniques are available to cut standby losses, most without using any new technologies. Simple redesign of circuits to avoid energizing unused components appears to save the most energy. A separate power supply, precisely designed for the actual power needed, is another solution. A switch mode power supply can substitute for the less efficient linear power supply. Switch mode power supplies cut no-load and standby losses by 60-80%. The combination of these techniques can cut leaking electricity by greater than 75%.

Huber, W.

1997-12-01T23:59:59.000Z

412

Management Training for Pathology Residents: A Regional Approach  

E-Print Network (OSTI)

RFI, RFP) Maintenance Supply management Contract services (Record maintenance, risk management * RFI indicates request

Wagar, E A

2004-01-01T23:59:59.000Z

413

Politics and Emergency Medicine - An Essential Lesson for Every Resident  

E-Print Network (OSTI)

and guide the future of emergency medicine. Volume XII, no .s S ection Politics and Emergency Medicine - An EssentialMedicine, Department of Emergency Medicine, Orange, CA Every

2011-01-01T23:59:59.000Z

414

VINOD NAMBOODIRI Status: U.S. Permanent Resident  

E-Print Network (OSTI)

of a Communication Infrastructure for the Distribution Level of the Smart Grid". 4. Anbarasan Shenbagraj, Vamshi R as it applies to Smart Grids and Green Computing Education · Ph.D. in Electrical and Computer Engineering and Awards · Research work on the use of wireless technologies for metering in smart grids was noticed

Namboodiri, Vinod

415

Alternative Fuels Data Center: Rhode Island Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Rhode Island Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Rhode Island Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Rhode Island Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Rhode Island Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Rhode Island Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Rhode Island Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Rhode Island Laws and Incentives for Propane (LPG)

416

Alternative Fuels Data Center: North Dakota Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: North Dakota Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: North Dakota Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: North Dakota Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: North Dakota Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: North Dakota Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: North Dakota Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type North Dakota Laws and Incentives for Propane (LPG)

417

Alternative Fuels Data Center: Connecticut Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Connecticut Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Connecticut Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Connecticut Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Connecticut Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Connecticut Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Connecticut Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Connecticut Laws and Incentives for Propane (LPG)

418

Alternative Fuels Data Center: Illinois Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Illinois Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Illinois Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Illinois Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Illinois Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Illinois Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Illinois Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Illinois Laws and Incentives for Propane (LPG)

419

Alternative Fuels Data Center: Nebraska Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Nebraska Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Nebraska Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Nebraska Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Nebraska Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Nebraska Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Nebraska Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Nebraska Laws and Incentives for Propane (LPG)

420

Alternative Fuels Data Center: Minnesota Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Minnesota Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Minnesota Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Minnesota Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Minnesota Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Minnesota Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Minnesota Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Minnesota Laws and Incentives for Propane (LPG)

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Alternative Fuels Data Center: New Mexico Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: New Mexico Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: New Mexico Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: New Mexico Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: New Mexico Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: New Mexico Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: New Mexico Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type New Mexico Laws and Incentives for Propane (LPG)

422

Alternative Fuels Data Center: Wisconsin Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Wisconsin Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Wisconsin Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Wisconsin Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Wisconsin Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Wisconsin Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Wisconsin Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Wisconsin Laws and Incentives for Propane (LPG)

423

Alternative Fuels Data Center: New Hampshire Laws and Incentives for  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: New Hampshire Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: New Hampshire Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: New Hampshire Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: New Hampshire Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: New Hampshire Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: New Hampshire Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type New Hampshire Laws and Incentives for Propane (LPG)

424

Alternative Fuels Data Center: Missouri Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Missouri Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Missouri Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Missouri Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Missouri Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Missouri Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Missouri Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Missouri Laws and Incentives for Propane (LPG)

425

Alternative Fuels Data Center: Colorado Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Colorado Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Colorado Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Colorado Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Colorado Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Colorado Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Colorado Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Colorado Laws and Incentives for Propane (LPG)

426

Alternative Fuels Data Center: Massachusetts Laws and Incentives for  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Massachusetts Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Massachusetts Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Massachusetts Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Massachusetts Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Massachusetts Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Massachusetts Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Massachusetts Laws and Incentives for Propane (LPG)

427

Alternative Fuels Data Center: Arizona Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Arizona Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Arizona Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Arizona Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Arizona Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Arizona Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Arizona Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Arizona Laws and Incentives for Propane (LPG)

428

Alternative Fuels Data Center: Alabama Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Alabama Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Alabama Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Alabama Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Alabama Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Alabama Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Alabama Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Alabama Laws and Incentives for Propane (LPG)

429

Alternative Fuels Data Center: Georgia Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Georgia Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Georgia Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Georgia Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Georgia Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Georgia Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Georgia Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Georgia Laws and Incentives for Propane (LPG)

430

Alternative Fuels Data Center: Tennessee Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Tennessee Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Tennessee Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Tennessee Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Tennessee Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Tennessee Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Tennessee Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Tennessee Laws and Incentives for Propane (LPG)

431

Alternative Fuels Data Center: Washington Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Washington Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Washington Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Washington Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Washington Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Washington Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Washington Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Washington Laws and Incentives for Propane (LPG)

432

Alternative Fuels Data Center: Kentucky Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Kentucky Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Kentucky Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Kentucky Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Kentucky Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Kentucky Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Kentucky Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Kentucky Laws and Incentives for Propane (LPG)

433

Alternative Fuels Data Center: Oklahoma Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Oklahoma Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Oklahoma Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Oklahoma Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Oklahoma Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Oklahoma Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Oklahoma Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Oklahoma Laws and Incentives for Propane (LPG)

434

Alternative Fuels Data Center: West Virginia Laws and Incentives for  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: West Virginia Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: West Virginia Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: West Virginia Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: West Virginia Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: West Virginia Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: West Virginia Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type West Virginia Laws and Incentives for Propane (LPG)

435

Alternative Fuels Data Center: California Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: California Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: California Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: California Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: California Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: California Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: California Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type California Laws and Incentives for Propane (LPG)

436

Alternative Fuels Data Center: Michigan Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Michigan Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Michigan Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Michigan Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Michigan Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Michigan Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Michigan Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Michigan Laws and Incentives for Propane (LPG)

437

Alternative Fuels Data Center: Louisiana Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Louisiana Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Louisiana Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Louisiana Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Louisiana Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Louisiana Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Louisiana Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Louisiana Laws and Incentives for Propane (LPG)

438

Alternative Fuels Data Center: Montana Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Montana Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Montana Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Montana Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Montana Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Montana Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Montana Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Montana Laws and Incentives for Propane (LPG)

439

Alternative Fuels Data Center: Pennsylvania Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Pennsylvania Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Pennsylvania Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Pennsylvania Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Pennsylvania Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Pennsylvania Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Pennsylvania Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Pennsylvania Laws and Incentives for Propane (LPG)

440

Alternative Fuels Data Center: New York Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: New York Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: New York Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: New York Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: New York Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: New York Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: New York Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type New York Laws and Incentives for Propane (LPG)

Note: This page contains sample records for the topic "resid lpg oth2" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Alternative Fuels Data Center: South Dakota Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: South Dakota Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: South Dakota Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: South Dakota Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: South Dakota Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: South Dakota Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: South Dakota Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type South Dakota Laws and Incentives for Propane (LPG)

442

Alternative Fuels Data Center: Indiana Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Indiana Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Indiana Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Indiana Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Indiana Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Indiana Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Indiana Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Indiana Laws and Incentives for Propane (LPG)

443

Alternative Fuels Data Center: Florida Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Florida Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Florida Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Florida Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Florida Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Florida Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Florida Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Florida Laws and Incentives for Propane (LPG)

444

Alternative Fuels Data Center: Arkansas Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Arkansas Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Arkansas Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Arkansas Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Arkansas Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Arkansas Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Arkansas Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Arkansas Laws and Incentives for Propane (LPG)

445

Alternative Fuels Data Center: Delaware Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Delaware Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Delaware Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Delaware Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Delaware Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Delaware Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Delaware Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Delaware Laws and Incentives for Propane (LPG)

446

Alternative Fuels Data Center: Mississippi Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Mississippi Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Mississippi Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Mississippi Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Mississippi Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Mississippi Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Mississippi Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Mississippi Laws and Incentives for Propane (LPG)

447

Alternative Fuels Data Center: Vermont Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Vermont Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Vermont Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Vermont Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Vermont Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Vermont Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Vermont Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Vermont Laws and Incentives for Propane (LPG)

448

Alternative Fuels Data Center: Maryland Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Maryland Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Maryland Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Maryland Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Maryland Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Maryland Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Maryland Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Maryland Laws and Incentives for Propane (LPG)

449

Alternative Fuels Data Center: Federal Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Federal Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Federal Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Federal Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Federal Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Federal Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Federal Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Federal Laws and Incentives for Propane (LPG)

450

Alternative Fuels Data Center: Virginia Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Virginia Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Virginia Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Virginia Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Virginia Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Virginia Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: Virginia Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Virginia Laws and Incentives for Propane (LPG)

451

Alternative Fuels Data Center: New Jersey Laws and Incentives for Propane  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: New Jersey Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: New Jersey Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: New Jersey Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: New Jersey Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: New Jersey Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: New Jersey Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type New Jersey Laws and Incentives for Propane (LPG)

452

Alternative Fuels Data Center: North Carolina Laws and Incentives for  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: North Carolina Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: North Carolina Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: North Carolina Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: North Carolina Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: North Carolina Laws and Incentives for Propane (LPG) on Digg Find More places to share Alternative Fuels Data Center: North Carolina Laws and Incentives for Propane (LPG) on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type

453

Alternative Fuels Data Center: Dist. of Columbia Laws and Incentives for  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Propane (LPG) to someone by E-mail Propane (LPG) to someone by E-mail Share Alternative Fuels Data Center: Dist. of Columbia Laws and Incentives for Propane (LPG) on Facebook Tweet about Alternative Fuels Data Center: Dist. of Columbia Laws and Incentives for Propane (LPG) on Twitter Bookmark Alternative Fuels Data Center: Dist. of Columbia Laws and Incentives for Propane (LPG) on Google Bookmark Alternative Fuels Data Center: Dist. of Columbia Laws and Incentives for Propane (LPG) on Delicious Rank Alternative Fuels Data Center: Dist. of Columbia Laws and Incent