Powered by Deep Web Technologies
Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Rapid road repair vehicle  

DOE Patents (OSTI)

Disclosed is a rapid road repair vehicle capable of moving over a surface to be repaired at near normal posted traffic speeds to scan for and find at the high rate of speed, imperfections in the pavement surface, prepare the surface imperfection for repair by air pressure and vacuum cleaning, applying a correct amount of the correct patching material to effect the repair, smooth the resulting repaired surface, and catalog the location and quality of the repairs for maintenance records of the road surface. The rapid road repair vehicle can repair surface imperfections at lower cost, improved quality, at a higher rate of speed than was not heretofor possible, with significantly reduced exposure to safety and health hazards associated with this kind of road repair activities in the past. 2 figs.

Mara, L.M.

1998-05-05T23:59:59.000Z

2

Rapid road repair vehicle  

DOE Patents (OSTI)

Disclosed is a rapid road repair vehicle capable of moving over a surface to be repaired at near normal posted traffic speeds to scan for and find an the high rate of speed, imperfections in the pavement surface, prepare the surface imperfection for repair by air pressure and vacuum cleaning, applying a correct amount of the correct patching material to effect the repair, smooth the resulting repaired surface, and catalog the location and quality of the repairs for maintenance records of the road surface. The rapid road repair vehicle can repair surface imperfections at lower cost, improved quality, at a higher rate of speed than was was heretofor possible, with significantly reduced exposure to safety and health hazards associated with this kind of road repair activities in the past.

Mara, Leo M. (Livermore, CA)

1998-01-01T23:59:59.000Z

3

Technological Advances in Pipeline Isolation and Repair  

Science Journals Connector (OSTI)

Pipeline isolation has been practised for many years to implement various repairs. The tools originally applied were simple and...

Dr A. Aldeen

1994-01-01T23:59:59.000Z

4

Update on pipeline repair methods  

SciTech Connect

A comprehensive review of pipeline repair methods has been recently completed under the sponsorship of the American Gas Association`s, Pipeline Research Committee. This paper is intended to summarize the important results of that review. First and foremost, two relatively new methods of repair are reviewed. One involves the use of a continuous-fiber fiberglass composite material which can be applied as an alternative to a steel sleeve for the reinforcement of nonleaking defects. The second is the use of deposited weld metal to replace metal lost to external corrosion. This latter technique is not new in principle, but recent research has shown how it can be done safely on a pressurized pipeline. The other significant outcome of the comprehensive review was a set of guidelines for using all types of repairs including full-encirclement sleeves and repair clamps. Pipeline operators can use these guidelines to enhance their current repair procedures, or to train new personnel in maintenance techniques.

Kiefner, J.F. [Kiefner and Associates, Inc., Worthington, OH (United States); Bruce, W.A. [Edison Welding Inst., Columbus, OH (United States); Stephens, D.R. [Battelle, Columbus, OH (United States)

1995-12-31T23:59:59.000Z

5

INTERNAL REPAIR OF PIPELINES  

SciTech Connect

The two broad categories of deposited weld metal repair and fiber-reinforced composite repair technologies were reviewed for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Preliminary test programs were developed for both deposited weld metal repairs and for fiber-reinforced composite repair. To date, all of the experimental work pertaining to the evaluation of potential repair methods has focused on fiber-reinforced composite repairs. Hydrostatic testing was also conducted on four pipeline sections with simulated corrosion damage: two with composite liners and two without.

Robin Gordon; Bill Bruce; Nancy Porter; Mike Sullivan; Chris Neary

2003-05-01T23:59:59.000Z

6

Robotic equipment for pipeline repair  

SciTech Connect

Hyperbaric welding provides the most reliable method for connection or repair of subsea oil and gas pipelines. Research on hyperbaric arc welding processes indicates that it should be possible to achieve stable welding conditions with Gas Tungsten Arc (GTA) to approximately 600m, and with Gas Metal Arc (GMA) and Plasma Arc to at least 1,000m. These depths are well beyond the limits of manned saturation diving. At the present time the limitation on the maximum depth to which these processes can be applied, in practice, is the requirement for completely diverless operation deeper than approximately 350m. Fully diverless hyperbaric welding is not presently available to the industry but several diverless pipeline repair systems which utilize mechanical connectors have been developed. This paper reviews the present status of mechanized hyperbaric welding systems currently being used in the North Sea and discusses some of the work being done to achieve fully diverless robotic pipeline repair with both welding and connectors.

Gibson, D.E.; Barratt, K.; Paterson, J. [National Hyperbaric Centre, Aberdeen (United Kingdom)

1995-12-31T23:59:59.000Z

7

INTERNAL REPAIR OF PIPELINES  

SciTech Connect

The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners, indicating that this type of liner is only marginally effective at restoring the pressure containing capabilities of pipelines. Failure pressures for larger diameter pipe repaired with a semi-circular patch of carbon fiber-reinforced composite lines were also marginally greater than that of a pipe section with un-repaired simulated damage without a liner. These results indicate that fiber reinforced composite liners have the potential to increase the burst pressure of pipe sections with external damage Carbon fiber based liners are viewed as more promising than glass fiber based liners because of the potential for more closely matching the mechanical properties of steel. Pipe repaired with weld deposition failed at pressures lower than that of un-repaired pipe in both the virgin and damaged conditions, indicating that this repair technology is less effective at restoring the pressure containing capability of pipe than a carbon fiber-reinforced liner repair. Physical testing indicates that carbon fiber-reinforced liner repair is the most promising technology evaluated to-date. In lieu of a field installation on an abandoned pipeline, a preliminary nondestructive testing protocol is being developed to determine the success or failure of the fiber-reinforced liner pipeline repairs. Optimization and validation activities for carbon-fiber repair methods are ongoing.

Bill Bruce; Nancy Porter; George Ritter; Matt Boring; Mark Lozev; Ian Harris; Bill Mohr; Dennis Harwig; Robin Gordon; Chris Neary; Mike Sullivan

2005-07-20T23:59:59.000Z

8

INTERNAL REPAIR OF PIPELINES  

SciTech Connect

The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners, indicating that this type of liner is only marginally effective at restoring the pressure containing capabilities of pipelines. Failure pressures for larger diameter pipe repaired with a semi-circular patch of carbon fiber-reinforced composite lines were also marginally greater than that of a pipe section with un-repaired simulated damage without a liner. These results indicate that fiber reinforced composite liners have the potential to increase the burst pressure of pipe sections with external damage Carbon fiber based liners are viewed as more promising than glass fiber based liners because of the potential for more closely matching the mechanical properties of steel. Pipe repaired with weld deposition failed at pressures lower than that of un-repaired pipe in both the virgin and damaged conditions, indicating that this repair technology is less effective at restoring the pressure containing capability of pipe than a carbon fiber-reinforced liner repair. Physical testing indicates that carbon fiber-reinforced liner repair is the most promising technology evaluated to-date. The first round of optimization and validation activities for carbon-fiber repairs are complete. Development of a comprehensive test plan for this process is recommended for use in the field trial portion of this program.

Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; George Ritter; Bill Mohr; Matt Boring; Nancy Porter; Mike Sullivan; Chris Neary

2004-12-31T23:59:59.000Z

9

INTERNAL REPAIR OF PIPELINES  

SciTech Connect

The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners, indicating that this type of liner is only marginally effective at restoring the pressure containing capabilities of pipelines. Failure pressures for larger diameter pipe repaired with a semi-circular patch of carbon fiber-reinforced composite lines were also marginally greater than that of a pipe section with un-repaired simulated damage without a liner. These results indicate that fiber reinforced composite liners have the potential to increase the burst pressure of pipe sections with external damage Carbon fiber based liners are viewed as more promising than glass fiber based liners because of the potential for more closely matching the mechanical properties of steel. Pipe repaired with weld deposition failed at pressures lower than that of un-repaired pipe in both the virgin and damaged conditions, indicating that this repair technology is less effective at restoring the pressure containing capability of pipe than a carbon fiber-reinforced liner repair. Physical testing indicates that carbon fiber-reinforced liner repair is the most promising technology evaluated to-date. Development of a comprehensive test plan for this process is recommended for use in the field trial portion of this program.

Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; George Ritter; Bill Mohr; Matt Boring; Nancy Porter; Mike Sullivan; Chris Neary

2004-08-17T23:59:59.000Z

10

Rapid road repair vehicle  

DOE Patents (OSTI)

Disclosed are improvments to a rapid road repair vehicle comprising an improved cleaning device arrangement, two dispensing arrays for filling defects more rapidly and efficiently, an array of pre-heaters to heat the road way surface in order to help the repair material better bond to the repaired surface, a means for detecting, measuring, and computing the number, location and volume of each of the detected surface imperfection, and a computer means schema for controlling the operation of the plurality of vehicle subsystems. The improved vehicle is, therefore, better able to perform its intended function of filling surface imperfections while moving over those surfaces at near normal traffic speeds.

Mara, Leo M. (Livermore, CA)

1999-01-01T23:59:59.000Z

11

INTERNAL REPAIR OF PIPELINES  

SciTech Connect

The two broad categories of deposited weld metal repair and fiber-reinforced composite liner repair technologies were reviewed for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Preliminary test programs were developed for both deposited weld metal repair and for fiber-reinforced composite liner repair. Evaluation trials have been conducted using a modified fiber-reinforced composite liner provided by RolaTube and pipe sections without liners. All pipe section specimens failed in areas of simulated damage. Pipe sections containing fiber-reinforced composite liners failed at pressures marginally greater than the pipe sections without liners. The next step is to evaluate a liner material with a modulus of elasticity approximately 95% of the modulus of elasticity for steel. Preliminary welding parameters were developed for deposited weld metal repair in preparation of the receipt of Pacific Gas & Electric's internal pipeline welding repair system (that was designed specifically for 559 mm (22 in.) diameter pipe) and the receipt of 559 mm (22 in.) pipe sections from Panhandle Eastern. The next steps are to transfer welding parameters to the PG&E system and to pressure test repaired pipe sections to failure. A survey of pipeline operators was conducted to better understand the needs and performance requirements of the natural gas transmission industry regarding internal repair. Completed surveys contained the following principal conclusions: (1) Use of internal weld repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling (HDD) when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) Pipe diameter sizes range from 50.8 mm (2 in.) through 1,219.2 mm (48 in.). The most common size range for 80% to 90% of operators surveyed is 508 mm to 762 mm (20 in. to 30 in.), with 95% using 558.8 mm (22 in.) pipe. An evaluation of potential repair methods clearly indicates that the project should continue to focus on the development of a repair process involving the use of GMAW welding and on the development of a repair process involving the use of fiber-reinforced composite liners.

Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; Nancy Porter; Mike Sullivan; Chris Neary

2004-04-12T23:59:59.000Z

12

Tank Remote Repair System Conceptual Design  

SciTech Connect

This document describes two conceptual designs for a Tank Remote Repair System to perform leak site repairs of double shell waste tank walls (Types I, II, III, and IIIA) from the annulus space. The first concept uses a magnetic wall crawler and an epoxy patch system and the second concept uses a magnetic wall crawler and a magnetic patch system. The recommended concept uses the magnetic patch system, since it is simpler to deliver, easier to apply, and has a higher probability of stopping an active leak.

Kriikku, E.

2002-12-06T23:59:59.000Z

13

Electric motor model repair specifications  

SciTech Connect

These model repair specifications list the minimum requirements for repair and overhaul of polyphase AC squireel cage induction motors. All power ranges, voltages, and speeds of squirrel cage motors are covered.

NONE

1995-08-01T23:59:59.000Z

14

APPLIED PHYSICS APPLIED PHYSICS  

E-Print Network (OSTI)

MSc APPLIED PHYSICS #12;MSc APPLIED PHYSICS This taught Masters course is based on the strong research in Applied Physics in the University's Department of Physics. The department has an impressive photonics and quantum optics, Physics and the Life Sciences, and solid state physics. The knowledge gained

Mottram, Nigel

15

CX-009354: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Determination CX-009354: Categorical Exclusion Determination High Resolution 3D Laser Imaging for Inspection, Maintenance, Repair and Operations - Phase II CX(s) Applied:...

16

CX-009331: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Determination CX-009331: Categorical Exclusion Determination High Resolution 3D Laser Imaging for Inspection, Maintenance, Repair and Operations Phase II CX(s) Applied:...

17

CX-010656: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Stormwater Drainage Repair CX(s) Applied: B1.3 Date: 06/18/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office

18

CX-009213: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CX-009213: Categorical Exclusion Determination Repair West Hackberry Brine Tanks, WHT-14 & WHT-15 CX(s) Applied: B1.3 Date: 08282012 Location(s): Louisiana...

19

CX-004894: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Exclusion Determination CX-004894: Categorical Exclusion Determination Peacock Substation Washed Out Area Repair CX(s) Applied: B1.3 Date: 11122009 Location(s): Mohave...

20

Inspect and Repair Steam Traps  

Energy.gov (U.S. Department of Energy (DOE))

This tip sheet on inspecting and repairing steam traps provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Review of Gas Transmission Pipeline Repair Methods  

Science Journals Connector (OSTI)

Repair methods are key operations for the integrity management of pipelines. The parameters guiding the repair decision are briefly reminded. A nonexhaustive external and internal repair techniques are described,...

Remi Batisse

2008-01-01T23:59:59.000Z

22

Evaluating Indoor Exposure Modeling Alternatives for LCA: A Case Study in the Vehicle Repair Industry  

Science Journals Connector (OSTI)

Evaluating Indoor Exposure Modeling Alternatives for LCA: A Case Study in the Vehicle Repair Industry ... Alternatives for modeling occupational exposure in LCA are evaluated using experimental monitoring data in the vehicle-repair industry. ... In addition to their use in occupational hygiene, exposure models may also be applied in environmental assessments, such as risk assessment (RA) and life-cycle assessment (LCA). ...

Evangelia Demou; Stefanie Hellweg; Michael P. Wilson; S. Katharine Hammond; Thomas E. McKone

2009-06-25T23:59:59.000Z

23

Adhesive technologies in repairing polyethylene pipelines  

Science Journals Connector (OSTI)

Adhesive technologies for repairing polyethylene pipelines are considered taking into account the peculiarities ... the modified binder for application in the gluing repair technologies under consideration. It is...

V. F. Stroganov

2014-07-01T23:59:59.000Z

24

Restore: Modeling Repair and Restoration Processes | Argonne...  

NLE Websites -- All DOE Office Websites (Extended Search)

Restore: Modeling Repair and Restoration Processes Restore: Modeling Repair and Restoration Processes Argonne's Restore software models complex sets of steps required to accomplish...

25

Earth Repair: A Transatlantic History of Environmental Restoration  

E-Print Network (OSTI)

Earth Repair: A Transatlantic History of EnvironmentalHall. Earth Repair: A Transatlantic History of Environmental

Hamilton-Smith, Elery

2006-01-01T23:59:59.000Z

26

Coal bunker repairs  

SciTech Connect

Detroit Edison's St. Clair Power Plant (STCPP) Units 1 through 4 are 1950's vintage fossil fueled units with an average capacity of 163 megawatt per unit. Each unit had identical 2190 ton bunkers. The Unit No. 1 bunker had been experiencing noticeable exterior deterioration at the lower level internal support system. An internal bunker inspection revealed large deflections in the network of beams supporting the bunker side walls. A complete collapse of the internal support beams was imminent. Failure of these beams would have transferred the coal pressure loads to the bunker skin and external stiffeners which were not capable of sustaining the load and were also showing signs of distress. This paper presents the temporary repair installed immediately after inspection, the redesign of the lower internal support system and construction procedures involved in bringing the bunker back into operating condition.

Emmons, M.H.; Hoffman, M.G. (Detroit Edison Co., MI (United States))

1992-01-01T23:59:59.000Z

27

Fatigue crack retardation by the application of repair coatings to gas pipelines under pressure  

Science Journals Connector (OSTI)

We describe additional capabilities of the repair insulation coatings applied to main pipelines (without taking them out of operation) in increasing the durability of these pipelines. As a specific feature of thi...

T. P. Venhrynyuk

2013-05-01T23:59:59.000Z

28

Large steam turbine repair: A survey  

SciTech Connect

This report covers a survey taken to document the current state-of-the-art in repairs to large steam turbines. One objective was to provide information to assist utilities in making repair or replacement decisions. The survey revealed that a large number of repairs have been successfully repaired involving both mechanical and welding repair techniques. Repair techniques have been improving in recent years and are being used more frequently. No guidelines or codes exist for the repair of steam turbine components so each repair is primarily controlled by agreement between the utility, contractor and insurer. Types of repairs are reviewed in this report and in addition, the capabilities of various contractors who are currently active in providing repair service. 40 refs., 10 figs., 4 tabs.

Findlan, S.J.; Lube, B. (EPRI Nondestructive Evaluation Center, Charlotte, NC (United States))

1991-07-01T23:59:59.000Z

29

Protein Bridges DNA Base and Nucleotide Excision Repair Pathways  

NLE Websites -- All DOE Office Websites (Extended Search)

Protein Bridges DNA Base and Protein Bridges DNA Base and Nucleotide Excision Repair Pathways Protein Bridges DNA Base and Nucleotide Excision Repair Pathways Print Wednesday, 28 October 2009 00:00 Alkyltransferase proteins (AGT) protect cells from the biological effects of DNA damage caused by the addition of alkyl groups (alkylation). Alkyltransferase-like proteins (ATLs) can do the same, but they lack the reactive cysteine residue that allows the alkyltransferase function, and the mechanism for cell protection has remained unknown. To address this mystery, a British-American team lead by researchers at the Scripps Research Institute recently applied a combination of x-ray structural, biochemical, and genetic studies to ATLs in the yeast Schizosaccharomyces pombe without and with damaged DNA. By showing how a process called non-enzymatic nucleotide flipping activates ATL-initiated DNA repair, their results may improve our understanding of genomic integrity and responses to DNA damage relevant to pathogens and cancer development.

30

Protein Bridges DNA Base and Nucleotide Excision Repair Pathways  

NLE Websites -- All DOE Office Websites (Extended Search)

Protein Bridges DNA Base and Nucleotide Excision Repair Pathways Print Protein Bridges DNA Base and Nucleotide Excision Repair Pathways Print Alkyltransferase proteins (AGT) protect cells from the biological effects of DNA damage caused by the addition of alkyl groups (alkylation). Alkyltransferase-like proteins (ATLs) can do the same, but they lack the reactive cysteine residue that allows the alkyltransferase function, and the mechanism for cell protection has remained unknown. To address this mystery, a British-American team lead by researchers at the Scripps Research Institute recently applied a combination of x-ray structural, biochemical, and genetic studies to ATLs in the yeast Schizosaccharomyces pombe without and with damaged DNA. By showing how a process called non-enzymatic nucleotide flipping activates ATL-initiated DNA repair, their results may improve our understanding of genomic integrity and responses to DNA damage relevant to pathogens and cancer development.

31

RECORD OF CATEGORICAL EXCLUSION DETERMINATION Hygiene Substation Access Road Repairs  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Hygiene Substation Access Road Repairs Hygiene Substation Access Road Repairs A. Brief Description of Proposal: Western Area Power Administration proposes to repair the access road/driveway into the Hygiene Substation. There is a low spot in the middle of the driveway that impedes maneuvering oflarge maintenance equipment in and out of the yard. Western plans to fill the low spot with road base and crumbled concrete fill. The Hygiene Substation is located in Boulder County, approximately 2 miles northwest of Longmont, CO (T3N, R69W, Sec 18). All proposed construction will occur within the existing, disturbed substation access road/driveway. B. Number and Title of tile Categorical Exclusion Being Applied: (See text in 10 CFR 1021, Subpart D.) BI.3 Routine maintenance activities and custodial services for buildings, structures,

32

Protein Bridges DNA Base and Nucleotide Excision Repair Pathways  

NLE Websites -- All DOE Office Websites (Extended Search)

Protein Bridges DNA Base and Nucleotide Excision Repair Pathways Print Protein Bridges DNA Base and Nucleotide Excision Repair Pathways Print Alkyltransferase proteins (AGT) protect cells from the biological effects of DNA damage caused by the addition of alkyl groups (alkylation). Alkyltransferase-like proteins (ATLs) can do the same, but they lack the reactive cysteine residue that allows the alkyltransferase function, and the mechanism for cell protection has remained unknown. To address this mystery, a British-American team lead by researchers at the Scripps Research Institute recently applied a combination of x-ray structural, biochemical, and genetic studies to ATLs in the yeast Schizosaccharomyces pombe without and with damaged DNA. By showing how a process called non-enzymatic nucleotide flipping activates ATL-initiated DNA repair, their results may improve our understanding of genomic integrity and responses to DNA damage relevant to pathogens and cancer development.

33

Protein Bridges DNA Base and Nucleotide Excision Repair Pathways  

NLE Websites -- All DOE Office Websites (Extended Search)

Protein Bridges DNA Base and Nucleotide Excision Repair Pathways Print Protein Bridges DNA Base and Nucleotide Excision Repair Pathways Print Alkyltransferase proteins (AGT) protect cells from the biological effects of DNA damage caused by the addition of alkyl groups (alkylation). Alkyltransferase-like proteins (ATLs) can do the same, but they lack the reactive cysteine residue that allows the alkyltransferase function, and the mechanism for cell protection has remained unknown. To address this mystery, a British-American team lead by researchers at the Scripps Research Institute recently applied a combination of x-ray structural, biochemical, and genetic studies to ATLs in the yeast Schizosaccharomyces pombe without and with damaged DNA. By showing how a process called non-enzymatic nucleotide flipping activates ATL-initiated DNA repair, their results may improve our understanding of genomic integrity and responses to DNA damage relevant to pathogens and cancer development.

34

Single molecule techniques in DNA repair: A primer  

Science Journals Connector (OSTI)

Abstract A powerful new approach has become much more widespread and offers insights into aspects of DNA repair unattainable with billions of molecules. Single molecule techniques can be used to image, manipulate or characterize the action of a single repair protein on a single strand of DNA. This allows search mechanisms to be probed, and the effects of force to be understood. These physical aspects can dominate a biochemical reaction, where at the ensemble level their nuances are obscured. In this paper we discuss some of the many technical advances that permit study at the single molecule level. We focus on DNA repair to which these techniques are actively being applied. DNA repair is also a process that encompasses so much of what single molecule studies benefit – searching for targets, complex formation, sequential biochemical reactions and substrate hand-off to name just a few. We discuss how single molecule biophysics is poised to transform our understanding of biological systems, in particular DNA repair.

Craig D. Hughes; Michelle Simons; Cassidy E. Mackenzie; Bennett Van Houten; Neil M. Kad

2014-01-01T23:59:59.000Z

35

Selected Bibliography on Electric Motor Repair | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Selected Bibliography on Electric Motor Repair Selected Bibliography on Electric Motor Repair The following series of repair documents related to electric motors were produced by...

36

Strongly Incremental Repair Detection Julian Hough  

E-Print Network (OSTI)

Strongly Incremental Repair Detection Julian Hough Dialogue Systems Group Faculty of Linguistics.purver@qmul.ac.uk Abstract We present STIR (STrongly Incremen- tal Repair detection), a system that de- tects speech repairs-theoretic measures from n-gram models as its principal decision features in a pipeline of classifiers detecting

Purver, Matthew

37

Providing protection: Agencies receive funding to repair, upgrade dams  

E-Print Network (OSTI)

Story by Kathy Wythe tx H2O | pg. 26 Providing protection Agencies receive funding to repair, upgrade dams along with local partners, can apply for grant funds, he said. Construction of the dams began through four federal authorizations... totaling about $11 million. Of the 343 dams currently classified as high hazard, Scattered across Texas are almost 2,000 nondescript, earthen dams built on private land to protect property, roads, and bridges from flood damages. Some of these dams...

Wythe, Kathy

2009-01-01T23:59:59.000Z

38

Development of a Remote External Repair Tool for Damaged or Defective Polyethylene Pipe  

SciTech Connect

Current procedures for repairing polyethylene (PE) gas pipe require excavation, isolation, and removal of the damaged section of pipe followed by fusing a new section of pipe into place. These techniques are costly and very disruptive. An alternative repair method was developed at Timberline Tool with support from Oregon State University (OSU) and funding by the U. S. Department of Energy National Energy Technology Laboratory (DOE/NETL). This project was undertaken to design, develop and test a tool and method for repairing damaged PE pipe remotely and externally in situ without squeezing off the flow of gas, eliminating the need for large-scale excavations. Through an iterative design and development approach, a final engineered prototype was developed that utilizes a unique thermo-chemical and mechanical process to apply a permanent external patch to repair small nicks, gouges and punctures under line pressure. The project identified several technical challenges during the design and development process. The repair tool must be capable of being installed under live conditions and operate in an 18-inch keyhole. This would eliminate the need for extensive excavations thus reducing the cost of the repair. Initially, the tool must be able to control the leak by encapsulating the pipe and apply slight pressure at the site of damage. Finally, the repair method must be permanent at typical operating pressures. The overall results of the project have established a permanent external repair method for use on damaged PE gas pipe in a safe and cost-effective manner. The engineered prototype was subjected to comprehensive testing and evaluation to validate the performance. Using the new repair tool, samples of 4-inch PE pipe with simulated damage were successfully repaired under line pressure to the satisfaction of DOE/NETL and the following natural gas companies: Northwest Natural; Sempra Energy, Southwest Gas Corporation, Questar, and Nicor. However, initial results of accelerated age testing on repaired pipe samples showed that the high density polyethylene (HDPE) pipe patch material developed a small crack at the high stress areas surrounding the patched hole within the first 48 hours of hot water testing, indicating that the patch material has a 25-year lifespan. Based on these results, further research is continuing to develop a stronger repair patch for a satisfactory 50-year patch system. Additional tests were also conducted to evaluate whether any of the critical performance properties of the PE pipe were reduced or compromised by the repair technique. This testing validated a satisfactory 50-year patch system for the pipe.

Kenneth H. Green; Willie E. Rochefort; Nick Wannenmacher; John A. Clark; Kevin Harris

2006-06-30T23:59:59.000Z

39

Use of Fiber Bragg Grating Strain Gages on a Pipeline Specimen Repaired with a CFRE Composite System  

Science Journals Connector (OSTI)

Re-establishing the maximum operating pressure of a segment of pipeline with metal loss defects, such as erosion ... segment altogether, or by applying a localized repair system. The present paper deals with labo...

J. L. F. Freire; V. A. Perrut…

2013-01-01T23:59:59.000Z

40

Sleeve installations speed pipeline defect repair  

SciTech Connect

Repairing defects in pipelines can be a major challenge for pipeline companies or contractors. To reduce cost and eliminate unscheduled shut downs, pipeline operating companies have adopted ``in-service`` repair methods to restore overall integrity of the pipeline without taking it out of service. Interprovincial Pipe Line Co. has undertaken an aggressive approach to this ``in-service`` repair method by using a developed sleeving system for repairing leaking and non-leaking defects. A structural reinforcement sleeve consists of two non-fillet welded collars (one on each side of the defect) and a full encirclement sleeve welded on top of these collars. The annular space between the pipe and sleeve is filled with a hardenable, non-shrinking epoxy. Three different pressure vessel sleeves can be used for repairing certain defects. They can be used in combination with the pre-stressed sleeve or for independent repairs. This paper reviews the performance and installation of these sleeves.

Friedrich, J.; Smith, J.

1995-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Single molecule studies of DNA mismatch repair  

Science Journals Connector (OSTI)

Abstract DNA mismatch repair, which involves is a widely conserved set of proteins, is essential to limit genetic drift in all organisms. The same system of proteins plays key roles in many cancer related cellular transactions in humans. Although the basic process has been reconstituted in vitro using purified components, many fundamental aspects of DNA mismatch repair remain hidden due in part to the complexity and transient nature of the interactions between the mismatch repair proteins and DNA substrates. Single molecule methods offer the capability to uncover these transient but complex interactions and allow novel insights into mechanisms that underlie DNA mismatch repair. In this review, we discuss applications of single molecule methodology including electron microscopy, atomic force microscopy, particle tracking, FRET, and optical trapping to studies of DNA mismatch repair. These studies have led to formulation of mechanistic models of how proteins identify single base mismatches in the vast background of matched DNA and signal for their repair.

Dorothy A. Erie; Keith R. Weninger

2014-01-01T23:59:59.000Z

42

Repair Geometric Model by the Healing Method  

Science Journals Connector (OSTI)

Repairing the panel CAD geometric model is an ... and analyzed by NURBS technology. Through the pipeline method determines the matching-curves border fast...

Di Chi; Wang Weibo; Wen Lishu; Liu Zhaozheng

2012-01-01T23:59:59.000Z

43

Tests validate pipeline sleeve repair technique  

SciTech Connect

The sleeve-on-sleeve pipeline-repair technique is a viable, acceptable means of repairing sleeves and preventing fluid leakage resulting from fracture of cracked fillet welds at the ends of an existing single-layer sleeve. This technique was conceived by Interprovincial Pipe Line Co. as a means of repair for situations in which one or both of the circumferential fillet welds at the ends of an initial repair sleeve may need to be reinforced. It was necessary to determine whether this technique can be employed without serious impairment of the integrity of the pipelines on which it is to be used.

Kiefner, J.F.; Maxey, W.A. (Battelle Memorial Inst., Columbus, OH (USA))

1989-08-28T23:59:59.000Z

44

Crews repair transmission lines after Washington wildfire  

NLE Websites -- All DOE Office Websites (Extended Search)

Privacy Publications Tribal Affairs Newsroom Search News Articles... Search Crews repair transmission lines after Washington wildfire 662014 12:00 AM Tweet Page Content BPA...

45

International congress on DNA damage and repair: Book of abstracts  

SciTech Connect

This document contains the abstracts of 105 papers presented at the Congress. Topics covered include the Escherichia coli nucleotide excision repair system, DNA repair in malignant transformations, defective DNA repair, and gene regulation. (TEM)

Not Available

1987-01-01T23:59:59.000Z

46

Repair of overheating linear accelerator  

SciTech Connect

Los Alamos Neutron Science Center (LANSCE) is a proton accelerator that produces high energy particle beams for experiments. These beams include neutrons and protons for diverse uses including radiography, isotope production, small feature study, lattice vibrations and material science. The Drift Tube Linear Accelerator (DTL) is the first portion of a half mile long linear section of accelerator that raises the beam energy from 750 keV to 100 MeV. In its 31st year of operation (2003), the DTL experienced serious issues. The first problem was the inability to maintain resonant frequency at full power. The second problem was increased occurrences of over-temperature failure of cooling hoses. These shortcomings led to an investigation during the 2003 yearly preventative maintenance shutdown that showed evidence of excessive heating: discolored interior tank walls and coper oxide deposition in the cooling circuits. Since overheating was suspected to be caused by compromised heat transfer, improving that was the focus of the repair effort. Investigations revealed copper oxide flow inhibition and iron oxide scale build up. Acid cleaning was implemented with careful attention to protection of the base metal, selection of components to clean and minimization of exposure times. The effort has been very successful in bringing the accelerator through a complete eight month run cycle allowing an incredible array of scientific experiments to be completed this year (2003-2004). This paper will describe the systems, investigation analysis, repair, return to production and conclusion.

Barkley, Walter; Baldwin, William; Bennett, Gloria; Bitteker, Leo; Borden, Michael; Casados, Jeff; Fitzgerald, Daniel; Gorman, Fred; Johnson, Kenneth; Kurennoy, Sergey; Martinez, Alberto; O’Hara, James; Perez, Edward; Roller, Brandon; Rybarcyk, Lawrence; Stark, Peter; Stockton, Jerry

2004-01-01T23:59:59.000Z

47

Human embryonic stem cells for brain repair?  

Science Journals Connector (OSTI)

...repair compiled by Siddharthan Chandran, Maeve Caldwell and Nick Allen Human embryonic stem cells for brain repair? Su-Chun...stromal cell co-culture system. This type of technique has merits in its simplicity and the differentiated progenies appear to...

2008-01-01T23:59:59.000Z

48

NSLS Services | Repair & Equipment Services  

NLE Websites -- All DOE Office Websites (Extended Search)

Repair & Equipment Services Repair & Equipment Services Cleaning Facility (BNL Central Shops) Solvent cleaning of vacuum parts and leak checking service is also available. Work is billed to each user via a BNL ILR. Contact the NSLS Building Manager to arrange for any of these services. Electronics Repair Limited repairs for electronic equipment are available from an outside contractor through the Control Room. Contact Control Room Supervisor Randy Church (x2550 or x2736, pager 5310). Shipping memos are filled out on the web, and pick ups are on Fridays. Come to the Control Room for assistance. The user should call the contractor on the day before scheduled pickups to alert the contractor of the pickup. Items to be repaired should be left in the Control Room with the completed shipping memo. Costs are charged to the

49

Integrated structural repair of a producing FPSO  

SciTech Connect

The state of the art in FPSO design is advancing rapidly. The long-term reliability of FPSO systems has improved as maintenance issues, have received greater emphasis in both new-builds and conversions. Despite this new emphasis, problems will still arise and repairs will still be required. Ultimately, the ability of any FPSO to stay on location and on production will depend on the scope of repairs which can be economically performed in-situ. In 1994 and 1995, Marathon Petroleum Indonesia Limited (MPIL) performed an in-situ repair on the FPSO Kakap Natuna. The scope and complexity of this work suggests there are few, if any, limits on in-situ structural repairs which can be successfully performed on a producing FPSO. The use of an integrated execution strategy for the repairs greatly reduced their cost.

Johnson, P.R. [Marathon Oil Co., Houston, TX (United States); Smith, T.A. [Aker Omega Inc., Houston, TX (United States)

1997-07-01T23:59:59.000Z

50

Chapter 4 - Pipeline Inspection and Subsea Repair  

Science Journals Connector (OSTI)

Abstract Pipeline inspection is a part of the pipeline integrity management for keeping the pipeline in good condition. The rules governing inspection are the pipeline safety regulations. In most cases the pipeline is inspected regularly. The pipeline safety regulations require that the operator shall insure that a pipeline is maintained in an efficient state, in efficient working order and in good repair. The pipeline inspection includes external inspection and internal inspection. In this chapter, the metal loss inspection techniques are discussed. The subsea pipeline internal inspection is normally carried out through non-destructive testing techniques and technologies by intelligent pigs, such as magnetic-flux leakage technology inn axial and circumferential, ultrasound technologies, eddy-current technologies and other technologies. The repair methods are different for shallow and deep water subsea pipelines. The conventional repair methods are used for shallow water pipeline, but diverless repair and intelligent plus are good for deepwater pipeline repair.

Yong Bai; Qiang Bai

2014-01-01T23:59:59.000Z

51

INTERNAL REPAIR OF PIPELINES REVIEW & EVALUATION OF INTERNAL PIPELINE REPAIR TRIALS REPORT  

SciTech Connect

The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners, indicating that this type of liner is generally ineffective at restoring the pressure containing capabilities of pipelines. Failure pressure for pipe repaired with carbon fiber-reinforced composite liner was greater than that of the un-repaired pipe section with damage, indicating that this type of liner is effective at restoring the pressure containing capability of pipe. Pipe repaired with weld deposition failed at pressures lower than that of un-repaired pipe in both the virgin and damaged conditions, indicating that this repair technology is less effective at restoring the pressure containing capability of pipe than a carbon fiber-reinforced liner repair. Physical testing indicates that carbon fiber-reinforced liner repair is the most promising technology evaluated to-date. Development of a comprehensive test plan for this process is recommended for use in the next phase of this project.

Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; George Ritter; Bill Mohr; Matt Boring; Nancy Porter; Mike Sullivan; Chris Neary

2004-09-01T23:59:59.000Z

52

Applied Science  

NLE Websites -- All DOE Office Websites (Extended Search)

Applied Science Applied Science Correlation of predicted and measured iron oxidation states in mixed iron oxides H. D. Rosenfeld and W. L. Holstein Development of a quantitative measurement of a diesel spray core using synchrotron x-rays C.F. Powell, Y. Yue, S. Gupta, A. McPherson, R. Poola, and J. Wang Localized phase transformations by x-ray-induced heating R.A. Rosenberg, Q. Ma, W. Farrell, E.D. Crozier, G.J. Soerensen, R.A. Gordon, and D.-T. Jiang Resonant x-ray scattering at the Se edge in ferroelectric liquid crystal materials L. Matkin, H. Gleeson, R. Pindak, P. Mach, C. Huang, G. Srajer, and J. Pollmann Synchrotron-radiation-induced anisotropic wet etching of GaAs Q. Ma, D.C. Mancini, and R.A. Rosenberg Synchrotron-radiation-induced, selective-area deposition of gold on

53

Diverless pipeline repair clamp: Phase 1  

SciTech Connect

Offshore oil and gas developments are underway for water depths beyond which divers can function. The economic lifelines of these projects are the pipelines which will transport the products to shore. In preparation for the day when one of these pipelines will require repair because of a leak, the Pipeline Research Committee of the American Gas Association is funding research directed at developing diverless pipeline repair capabilities. Several types of damage are possible, ranging from latent weld defects on one end of the spectrum to damage resulting in parting of the pipe at the other end. This study is specifically directed toward laying the groundwork for development of a diverless pipeline repair clamp for use in repair of leaks resulting from minor pipe defects. The incentive for a clamp type repair is costs. When compared to replacing a section of pipe, either by welding or by mechanical means, the clamp type repair requires much less disturbance of the pipe, less time, fewer operations and less equipment. This report summarizes (1) capabilities of remotely operated vehicles (ROV's) and associated systems, (2) highlights areas for further research and development, (3) describes the required capabilities of the diverless repairclamp, (4) investigates some alternatives to the diverless clamp, (5) overviews the state of the art in leak repair clamps, and (6) critiques several possible generic clamp concepts.

Miller, J.E.; Knott, B. (Stress Engineering Services, Inc., Houston, TX (United States))

1991-12-01T23:59:59.000Z

54

Deepwater pipeline repair technology: A general overview  

SciTech Connect

During the life of oil and gas transportation sea lines, periodic inspection, maintenance and repair in case of major damage are the most important tasks to be considered especially in deepwater installations. In particular the capabilities to perform quick and cost effective repairs have been of strategic importance in the eighties for SNAM during the development of the S.A.S. (Submersible Automatic System) a diverless and guidelineless repair system for the 20 inch Transmediterranean sealines. The trials on this prototype were successfully completed in early summer 1992, simulating a complete repair procedure at 610 in water depth. Based on the technology the authors have acquired during the implementation of the system, an upgrading phase aimed at improving the capability to mate the new 26 inch lines is being developed. Considering that at the moment only a few pipeline transportation systems are laid in deep water, but some new installations are foreseen in the near future, technological developments would be necessary in view of different scenarios other than the Mediterranean area. This paper will be focused on an overview of the existing repair technologies and will discuss the possible future pipelines operating scenarios and the envisaged new developments of repair technology. Possible way of approaching and solving in a cost-effective way the needs of Pipeline Operators to have repair systems available will be discussed for the different pipeline scenarios.

Magnelli, G.; Radicioni, A. [Snamprogetti S.p.A., Fano (Italy). Offshore Division

1994-12-31T23:59:59.000Z

55

Developments advance subsea pipelaying, inspection, repair  

SciTech Connect

Recent advances in laying, inspecting, and repairing pipelines are helping to cut both costs and time. A new dredging system that employs jets to clear a subsea trench for pipelay received trials off Belgium last spring. Also, within the last year, projects in the Middle East and North Sea employed technologies that promise to make inspecting the surface of a subsea pipeline in difficult terrain easier, less time consuming, and therefore less costly. Plus, subsea repair of damaged pipelines may take less time with a new ``stabbable`` pipe connector. The paper describes jet dredging, inspection advance, support software, the North Sea site, and pipeline repair.

NONE

1997-09-15T23:59:59.000Z

56

Joint Characterisation for Repair Brazing of Superalloys  

Science Journals Connector (OSTI)

The restricted weldability of superalloys that can operate at high temperatures and under mechanical loadings, required in modern gas turbines, has lead to the development of repair brazing techniques for vari...

L. S. K. Heikinheimo; A. Laukkanen; J. Veivo

2005-05-01T23:59:59.000Z

57

Encirclement sleeves reduce pipeline repair costs  

SciTech Connect

Welded sleeve, or replacement of line repair methods have been used successfully for many years in the pipeline industry but can lead to other difficulties for a pipeline operator. Clock Spring`s composite sleeves have been used in over ten thousand pipeline repairs with pipe sizes ranging from 6- to 56-inches in diameter, all without costly shutdown, welding or purging. Repairs can be completed while the pipeline is fully operational and require only six inches of clearance under the pipe for wrapping the eight thicknesses of the coil. This minimizes costly digging and backfilling over long runs of pipe and necessary shoring for personnel safety. Also it provides a more cost-effective alterative to conventional pipeline repair since special handling, lifting, or installation equipment is not needed. This paper reviews the installation and performance of these sleeves.

NONE

1996-01-01T23:59:59.000Z

58

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

August 13, 2013 August 13, 2013 CX-011158: Categorical Exclusion Determination Subcontractor Repair of Roof Leaks at 717-11A CX(s) Applied: B1.3 Date: 08/13/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 13, 2013 CX-011157: Categorical Exclusion Determination Subcontractor Roof Repairs in Telecom Room at 702-C CX(s) Applied: B1.3 Date: 08/13/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 8, 2013 CX-011163: Categorical Exclusion Determination Subcontractor Repair of Roof Leaks at 730-4B CX(s) Applied: B1.3 Date: 08/08/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 8, 2013 CX-011162: Categorical Exclusion Determination Subcontractor Repair of Roof Leaks at 730-1B CX(s) Applied: B1.3

59

CX-007956: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

High Resolution 3-Dimensional Laser Imaging for Inspection, Maintenance, Repair, and Operations CX(s) Applied: B3.6 Date: 01/30/2012 Location(s): California Offices(s): National Energy Technology Laboratory

60

CX-007461: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

High Resolution 3-dimensional Laser Imaging for Inspection, Maintenance, Repair and Operations - Phase II CX(s) Applied: B3.6 Date: 12/20/2011 Location(s): Colorado Offices(s): National Energy Technology Laboratory

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

CX-012388: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Subcontractor Repair of Roof Leaks 108-1K CX(s) Applied: B1.3 Date: 05/13/2014 Location(s): South Carolina Offices(s): Savannah River Operations Office

62

CX-012342: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Liberty Parker #2 Transmission Line - Erosion Repair at Structure 53/1 CX(s) Applied: B4.6 Date: 06/09/2014 Location(s): Arizona Offices(s): Western Area Power Administration-Desert Southwest Region

63

CX-012337: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Maintain/Repair SPR Radio Communications Network, 2014-2017 CX(s) Applied: B1.7 Date: 06/11/2014 Location(s): CX: none Offices(s): Strategic Petroleum Reserve Field Office

64

CX-010106: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Flaming Gorge Microwave Site Communications Building Access Road Repairs CX(s) Applied: B1.3 Date: 04/01/2013 Location(s): Utah Offices(s): Western Area Power Administration-Rocky Mountain Region

65

CX-008638: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Exclusion Determination Excavate to Repair Underground Domestic Water Leak between Tanks 5 and 7 CX(s) Applied: B1.3 Date: 05292012 Location(s): South Carolina Offices(s):...

66

CX-012335: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Offsite Inspection and Repair of DOE Workover Rig #155 (PR 10090916) CX(s) Applied: B1.3 Date: 06/24/2014 Location(s): CX: none Offices(s): Strategic Petroleum Reserve Field Office

67

CX-006955: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CX(s) Applied: B1.3 Date: 09282011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Sandia Site Office This is a painting job to repair some fixed...

68

CX-011203: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Damage Repairs to the Gila North Gila, Gila Knob, and Sonora San Luis Transmission Lines, near Yuma, Yuma County, Arizona CX(s) Applied: B4.6 Date: 08262013 Location(s):...

69

CX-006698: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Determination CX-006698: Categorical Exclusion Determination Planned Repair of Flow Lines CX(s) Applied: B5.4 Date: 08092011 Location(s): Casper, Wyoming Office(s): RMOTC...

70

CX-009510: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CX-009510: Categorical Exclusion Determination Strategic Petroleum Reserve Emergency Pipeline and Piping Repair, 2013-2017 CX(s) Applied: B5.4 Date: 10302012 Location(s):...

71

CX-011839: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

MiniBooNE Berme Repair CX(s) Applied: B2.5 Date: 01/15/2014 Location(s): Illinois Offices(s): Fermi Site Office

72

CX-010543: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CX-010543: Categorical Exclusion Determination Repair of Big Hill Texas-14 Transformer CX(s) Applied: B1.3 Date: 06242013 Location(s): Texas Offices(s): Strategic...

73

CX-010886: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Curecanti-Lost Canyon 230-Kilovolt Emergency Repairs of Downed Conductor CX(s) Applied: B1.3 Date: 08/06/2013 Location(s): Colorado Offices(s): Western Area Power Administration-Rocky Mountain Region

74

CX-010655: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Roof Repair on Crane Maintenance Area Roof CX(s) Applied: B1.3 Date: 06/20/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office

75

Application of composite repair for pipeline anomalies  

SciTech Connect

The cost of maintaining the structural integrity of the 650,000 kilometer high-pressure gas gathering and transmission pipeline network is a significant part of the operating budget of the US pipeline industry. To help in controlling thee costs, the Gas Research institute (GRI) has supported research resulting in the development of Clock Spring{reg_sign}, a low-cost fiberglass composite alternative to conventional steel sleeves for transmission line pipe reinforcement and repair. Investigation and development of engineering guidelines have been completed. Field validation of laboratory research on application of Clock Spring as a repair for corrosion and mechanical damage defects is in progress. This paper presents an overview of composite repair technology for pipeline corrosion and mechanical damage defects. It summarizes the results and conclusions of modeling and experiments on reinforcement and repair of both corrosion and mechanical damage (i.e., dent and gouge) pipeline defects. These investigations provide quantitative results on the operating envelope of composite reinforcements and installation requirements that ensure sound and reliable repair of pipeline defects. The paper further summarizes the work to date on field installation in verification of composite repair performance.

Stephens, D.R. [Battelle, Columbus, OH (United States); Lindholm, U.S. [Southwest Research Inst., San Antonio, TX (United States); Hill, V.L. [Gas Research Inst., Chicago, IL (United States); Block, N. [Clock Spring Co., Houston, TX (United States)

1996-09-01T23:59:59.000Z

76

Energy and Technology Review: Unlocking the mysteries of DNA repair  

SciTech Connect

DNA, the genetic blueprint, has the remarkable property of encoding its own repair following diverse types of structural damage induced by external agents or normal metabolism. We are studying the interplay of DNA damaging agents, repair genes, and their protein products to decipher the complex biochemical pathways that mediate such repair. Our research focuses on repair processes that correct DNA damage produced by chemical mutagens and radiation, both ionizing and ultraviolet. The most important type of DNA repair in human cells is called excision repair. This multistep process removes damaged or inappropriate pieces of DNA -- often as a string of 29 nucleotides containing the damage -- and replaces them with intact ones. We have isolated, cloned, and mapped several human repair genes associated with the nucleotide excision repair pathway and involved in the repair of DNA damage after exposure to ultraviolet light or mutagens in cooked food. We have shown that a defect in one of these repair genes, ERCC2, is responsible for the repair deficiency in one of the groups of patients with the recessive genetic disorder xeroderma pigmentosum (XP group D). We are exploring ways to purify sufficient quantities (milligrams) of the protein products of these and other repair genes so that we can understand their functions. Our long-term goals are to link defective repair proteins to human DNA repair disorders that predispose to cancer, and to produce DNA-repair-deficient mice that can serve as models for the human disorders.

Quirk, W.A.

1993-04-01T23:59:59.000Z

77

INTERNAL REPAIR OF GAS PIPLINES SURVEY OF OPERATOR EXPERIENCE AND INDUSTRY NEEDS REPORT  

SciTech Connect

A repair method that can be applied from the inside of a gas transmission pipeline (i.e., a trenchless repair) is an attractive alternative to conventional repair methods since the need to excavate the pipeline is precluded. This is particularly true for pipelines in environmentally sensitive and highly populated areas. The objectives of the project are to evaluate, develop, demonstrate, and validate internal repair methods for pipelines; develop a functional specification for an internal pipeline repair system; and prepare a recommended practice for internal repair of pipelines. The purpose of this survey is to better understand the needs and performance requirements of the natural gas transmission industry regarding internal repair. A total of fifty-six surveys were sent to pipeline operators. A total of twenty completed surveys were returned, representing a 36% response rate, which is considered very good given the fact that tailored surveys are known in the marketing industry to seldom attract more than a 10% response rate. The twenty survey responses produced the following principal conclusions: (1) Use of internal weld repair is most attractive for river crossings, under other bodies of water (e.g., lakes and swamps) in difficult soil conditions, under highways, under congested intersections, and under railway crossings. All these areas tend to be very difficult and very costly if, and where, conventional excavated repairs may be currently used. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling (HDD) when a new bore must be created to solve a leak or other problem in a water/river crossing. (3) The typical travel distances required can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). In concept, these groups require pig-based systems; despooled umbilical systems could be considered for the first two groups. For the last group a self-propelled system with an onboard self-contained power and welding system is required. (4) Pipe size range requirements range from 50.8 mm (2 in.) through 1,219.2 mm (48 in.) in diameter. The most common size range for 80% to 90% of operators surveyed is 508 mm to 762 mm (20 in. to 30 in.) diameter, with 95% using 558.8 mm (22 in.) diameter pipe.

Ian D. Harris

2003-09-01T23:59:59.000Z

78

HANFORD SITE LOW EXPOSURE PIPELINE REPAIR USING A NON-METALLIC COMPOSITE SYSTEM  

SciTech Connect

At the Department of Energy, Richland Operations (DOE-RL) Hanford site in eastern Washington, a 350 mm (14 inch) diameter high density polyethylene (HDPE) pump recirculation pipeline failed at a bonded joint adjacent to a radiologically and chemically contaminated groundwater storage basin. The responsible DOE-RL contractor, CH2MHill Plateau Remediation Company, applied a fiberglass reinforced plastic (composite) field repair system to the failed joint. The system was devised specifically for the HDPE pipe repair at the Hanford site, and had not been used on this type of plastic piping previously. This paper introduces the pipe failure scenario, describes the options considered for repair and discusses the ultimate resolution of the problem. The failed pipeline was successfully returned to service with minimal impact on waste water treatment plant operating capacity. Additionally, radiological and chemical exposures to facility personnel were maintained as low as reasonably achievable (ALARA). The repair is considered a success for the near term, and future monitoring will prove whether the repair can be considered for long term service and as a viable alternative for similar piping failures at the Hanford site.

HUTH RJ

2009-11-12T23:59:59.000Z

79

E-Print Network 3.0 - auto body repair Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

"repairable assets... of which can be plugged into SAWA. Figure 1. Repairable Assets Pipeline 2 Repairable Assets ... Source: Baclawski, Kenneth B. - College of Computer...

80

Repair of mismatched basepairs in mammalian DNA  

SciTech Connect

We have concentrated on three specific areas of our research plan. Our greatest emphasis is on the role of single strand nicks in influencing template strand selection in mismatch repair. We have found, that the ability of a nick in one strand to influence which strand is repaired is not a simple function of distance from the mismatched site but rather that an hot spot where a nick is more likely to have an influence can exist. The second line was production of single-genotype heteroduplexes in order to examine independently the repair of T/G and A/C mispairs within the same sequence context as in our mixed mispair preparations. We have shown preparations of supercoiled heteroduplex can be prepared that were exclusively T/G or exclusively A/C at the mispair site. The third effort has been to understand the difference in repair bias of different cell lines or different transfection conditions as it may relate to different repair systems in the cell. We have identified some of the sources of variation, including cell cycle position. We hope to continue this work to more precisely identify the phase of the cell cycle.

Taylor, J.H.; Hare, J.T.

1991-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Fabrication Flaws in Reactor Pressure Vessel Repair Welds  

SciTech Connect

This paper describes the fabrication flaw distribution and characterization in the repair weld metal of reactor pressure vessels. This work indicates that the large flaws occur in these repairs. These results show that repair flaws are complex in composition and sometimes include cracks on the repair ends. Parametric analysis using an exponential fit is performed on the data. A description of repair flaw morphology is provided. Fabrication flaws in repairs are characterized using high sensitivity nondestructive ultrasonic testing, validation by other nondestructive evaluation (NDE) techniques, and complemented by destructive testing.

Schuster, George J.; Doctor, Steven R.

2007-12-01T23:59:59.000Z

82

Repairable chip bonding/interconnect process  

DOE Patents (OSTI)

A repairable, chip-to-board interconnect process which addresses cost and testability issues in the multi-chip modules. This process can be carried out using a chip-on-sacrificial-substrate technique, involving laser processing. This process avoids the curing/solvent evolution problems encountered in prior approaches, as well is resolving prior plating problems and the requirements for fillets. For repairable high speed chip-to-board connection, transmission lines can be formed on the sides of the chip from chip bond pads, ending in a gull wing at the bottom of the chip for subsequent solder.

Bernhardt, Anthony F. (Berkeley, CA); Contolini, Robert J. (Livermore, CA); Malba, Vincent (Livermore, CA); Riddle, Robert A. (Tracy, CA)

1997-01-01T23:59:59.000Z

83

Development of a composite repair system for reinforcing offshore risers  

E-Print Network (OSTI)

A research program was conducted to investigate the application of composite materials in repairing corroded offshore risers, leading to the development of an optimized repair using a hybrid carbon/E-glass system. The objective of this research...

Alexander, Christopher Richard

2009-05-15T23:59:59.000Z

84

In-service repair of main pipelines by welding  

Science Journals Connector (OSTI)

A new approach to the repair of main pipelines by welding without removing them from service ... failure risk; safety of welding works on pipeline under pressure; use of different variants of repair by welding; s...

V. I. Makhnenko; V. S. But; O. I. Oleinik

2009-09-01T23:59:59.000Z

85

Improving the Design Reliability of Petroleum Pipeline Components on Repair  

Science Journals Connector (OSTI)

Developments are considered that may appreciably improve the design reliability in the repair of petroleum pipeline components.

I. N. Karelin

86

Strongly Incremental Repair Detection Julian Hough1,2  

E-Print Network (OSTI)

in a pipeline of classifiers detecting the the different stages of repairs. Results on the Switchboard disStrongly Incremental Repair Detection Julian Hough1,2 1 Dialogue Systems Group Faculty of London m.purver@qmul.ac.uk Abstract We present STIR (STrongly Incremen- tal Repair detection), a system

Purver, Matthew

87

Pipeline incidents and emergency repair in the North Sea  

SciTech Connect

The failures of submarine pipelines in the North Sea, and the response of pipeline operators are first discussed. Against this background, the methods currently available for submarine pipeline repairs are reviewed. The Emergency Pipeline Repair Services available are described, and some future developments in the field of submarine pipeline repair are briefly outlined.

Wood, G.D.

1988-12-01T23:59:59.000Z

88

Categorical Exclusion Determinations: B1.3 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

June 20, 2013 June 20, 2013 CX-010655: Categorical Exclusion Determination Roof Repair on Crane Maintenance Area Roof CX(s) Applied: B1.3 Date: 06/20/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office June 18, 2013 CX-010656: Categorical Exclusion Determination Stormwater Drainage Repair CX(s) Applied: B1.3 Date: 06/18/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office June 17, 2013 CX-010662: Categorical Exclusion Determination Reroute Diesel Water Cooling Line at 241-125H CX(s) Applied: B1.3 Date: 06/17/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office June 17, 2013 CX-010661: Categorical Exclusion Determination Repair Roof at 717-K CX(s) Applied: B1.3 Date: 06/17/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office

89

Actions to promote energy-efficient electric motor repair  

Science Journals Connector (OSTI)

Electric motors are repaired 2-3 times over their lifetime. Poor repair practices, particularly widespread in developing countries, can lead to a significant increase in motor losses. It is estimated that worldwide poor repair leads to annual electricity losses of approximately 40 TWh, representing 20 Mtons of CO2 emissions. The main objective of this paper is to provide a technical basis for designing demand side management actions, which address the motor repair market. This paper brings into focus motor repair process trends, energy-efficient motors, typical repair process, actions to promote energy-efficient motor repair, energy-efficient motor rebate schemes to replace old, badly damaged motors and the factors influencing payback. This paper will be useful to energy policy makers, and Demand Side Management (DSM) staff in energy agencies and electric utilities.

Aníbal T. de Almeida; Fernando J.T.E. Ferreira

2003-01-01T23:59:59.000Z

90

Distribution System Audits, Leak Detection, and Repair: Kirtland Air Force Base Leak Detection and Repair Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Best Management Practice Best Management Practice Case Study #3 Distribution System Audits, Leak Detection, and Repair Kirtland Air Force Base - Leak Detection and Repair Program Overview Kirtland Air Force Base (AFB) performed an award winning leak detection and repair program in 2006. The results of the project are saving Kirtland AFB 179 million gallons each year, which is over 16% of the total water use at the base. Kirtland AFB is located on 52,000 acres, southeast and adjacent to Albuquerque, New Mexico. The area is a high altitude desert, only receiving about 8 inches of rain each year. Kirtland AFB draws water from an under- ground aquifer via seven production wells through- out the base. The base also has access to water from the City of Albuquerque. The underground water

91

Distribution System Audits, Leak Detection, and Repair: Kirtland Air Force Base Leak Detection and Repair Program  

NLE Websites -- All DOE Office Websites (Extended Search)

Best Management Practice Best Management Practice Case Study #3 Distribution System Audits, Leak Detection, and Repair Kirtland Air Force Base - Leak Detection and Repair Program Overview Kirtland Air Force Base (AFB) performed an award winning leak detection and repair program in 2006. The results of the project are saving Kirtland AFB 179 million gallons each year, which is over 16% of the total water use at the base. Kirtland AFB is located on 52,000 acres, southeast and adjacent to Albuquerque, New Mexico. The area is a high altitude desert, only receiving about 8 inches of rain each year. Kirtland AFB draws water from an under- ground aquifer via seven production wells through- out the base. The base also has access to water from the City of Albuquerque. The underground water

92

Low Dose Radiation Research Program: Quantification of Repair of  

NLE Websites -- All DOE Office Websites (Extended Search)

Quantification of Repair of Low-Dose-Induced DNA Double-Strand Quantification of Repair of Low-Dose-Induced DNA Double-Strand Breaks in Diploid Human Cells Authors: David Schild,1 and Larry H. Thompson,2 Institutions: 1Life Sciences Division, Lawrence Berkeley National Laboratory; and 2BBR Program, Lawrence Livermore National Laboratory Double-strand breaks (DSBs) are the biochemical lesions of primary concern in radiation related health effects. Compelling evidence from rodent and chicken model systems indicates that homologous recombinational repair (HRR) plays an essential role for cell viability in the repair of spontaneous DSBs arising during DNA replication and an important role in the repair of IR-induced DSBs. IR-induced DSBs are also repaired by error-prone nonhomologous end joining (NHEJ). Using hTERT-immortalized

93

Rapid pipeline repair technology for war damage recovery. Technical note  

SciTech Connect

This report documents the development of three experimental pipeline couplers for rapid repair of fuel lines damaged in an attack. The experimental couplers are: (1) the Cold Forge coupler, (2) the Internal Coupler, and (3) the Inflatable Seal Coupler. The focus of the evaluation was to determine the feasibility of rapidly repairing bomb-damaged fuel lines with each coupler, particularly underground pipelines made of carbon steel. Evaluating the feasibility of repair with each coupler was based on such aspects as installations speed and effectiveness. The test results confirmed that each coupler could be used during base recovery, operations to rapidly and effectively repair a fuel pipeline that may be out-of-round or highly misaligned. Recommended that each experimental coupler be taken into advanced development for extensive testing and field evaluation. Base recovery, Expedient pipeline repair, Utility repair.

Anguiano, G.

1993-06-01T23:59:59.000Z

94

Analyses of cracks in thick stiffened plates repaired with single-sided composite patch  

Science Journals Connector (OSTI)

Abstract This study investigated the effect of composite patches applied to thick stiffened plates with single-sided repairs. A simplified analytical model was derived to predict the reduction in the mode I strain energy release rates resulting from the single-sided composite patches. Finite element analyses were also conducted to compute the mode I strain energy release rates with and without composite patches, and their results were compared to the analytical model prediction. Furthermore, changes in the location of the neural axis with single-side patches were examined with their effects on the effectiveness of the patch repair with variations in both material and geometric parameters of the patch and plate. The neutral axis location in the patched plate played an important role to influence the effectiveness of the composite patch.

Y.W. Kwon; B.L. Hall

2015-01-01T23:59:59.000Z

95

Analysis of a glass fibre reinforced polyurethane composite repair system for corroded pipelines at elevated temperatures  

Science Journals Connector (OSTI)

Abstract The present paper is concerned with the analysis of glass fibre reinforced polyurethane repair systems for metallic pipelines with localised corrosion damage that impair the serviceability. The main motivation for the study presented in this paper is the rehabilitation of corroded pipelines conveying produced water in offshore oil platforms. Although the operating pressure of these pipelines is not very high, the water temperature is between 60 and 90°C, which can be a major shortcoming for the use of polymeric material as repair systems. Tensile tests were performed to analyse the temperature dependence of a polyurethane pre-impregnated, bi-directional E-glass fibre composite. Burst tests were carried out to evaluate the performance of composite reinforcements applied to defects machined in pipeline test specimens. Preliminary ideas for a methodology to estimate the failure pressure of a reinforced specimen with arbitrary localised corrosion damage are presented.

H.S. da Costa Mattos; J.M.L. Reis; L.M. Paim; M.L. da Silva; F.C. Amorim; V.A. Perrut

2014-01-01T23:59:59.000Z

96

theoretical and applied fracture  

E-Print Network (OSTI)

theoretical and applied fracture mechanics ELSEVIER Theoretical and Applied Fracture Mechanics 00 and Applied Fracture Mechanics 00 (1995) 000-000 Recently, some European countries developed defect specific. A suitable probabilistic fracture mechanic

Cizelj, Leon

97

Window Replacement, Rehabilitation, & Repair Guides- Building America Top Innovation  

Energy.gov (U.S. Department of Energy (DOE))

Building America team Building Science Corporation guides contractors through several options for repairing or replacing old windows to improve air sealing and thermal performance.

98

Underwater Pipeline Repair in Difficult Seabed Conditions: Problems and Solutions  

Science Journals Connector (OSTI)

This paper examines the application of innovative technology to significantly reduce the time for a major repair to a 36 inch diameter buried submarine pipeline.

B. A. Jones; N. Wright

1994-01-01T23:59:59.000Z

99

Modelling repairable system reliability with explanatory variables and repair and maintenance actions  

Science Journals Connector (OSTI)

......However, in general, in RMs...overhaul of an engine (a midlife...used with diesel engines...g. from diesel engines, such as...is a quite general model, and...analysis of diesel engine failure data...systems with general repair......

Diederik Lugtigheid; agan Banjevic; Andrew K. S. Jardine

2004-04-01T23:59:59.000Z

100

CX-006661: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CX(s) Applied: B5.2, B5.4 Date: 02242010 Location(s): Casper, Wyoming Office(s): RMOTC Repair a flowline leak and test the line at 83-AX-4. Dug up pipeline, repaired line and...

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Applying lean manufacturing initiatives to naval ship repair centers : implementation and lessons learned  

E-Print Network (OSTI)

The United States Navy is under pressure to reduce the cost of fleet maintenance in order to redirect funds for the construction of new ships and submarines. The Navy looks to private industry for process improvement ideas ...

Murphy, Brian P. (Brian Patrick), 1963-

2004-01-01T23:59:59.000Z

102

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

June 20, 2013 June 20, 2013 CX-010655: Categorical Exclusion Determination Roof Repair on Crane Maintenance Area Roof CX(s) Applied: B1.3 Date: 06/20/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office June 18, 2013 CX-010657: Categorical Exclusion Determination Western Sector Treatment System Soil Vapor Extraction Wells CX(s) Applied: B3.1 Date: 06/18/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office June 18, 2013 CX-010656: Categorical Exclusion Determination Stormwater Drainage Repair CX(s) Applied: B1.3 Date: 06/18/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office June 17, 2013 CX-010662: Categorical Exclusion Determination Reroute Diesel Water Cooling Line at 241-125H CX(s) Applied: B1.3 Date: 06/17/2013

103

Availability Analysis of Repairable Computer Systems and Stationarity Detection  

E-Print Network (OSTI)

Availability Analysis of Repairable Computer Systems and Stationarity Detection Bruno Sericola computer system and we assume, as usual, that the system is modeled by a finite Markov process. We propose of performability measures. Index TermsÐRepairable computer systems, dependability, availability, performability

Sericola, Bruno

104

Proceedings of design, repair, and refurbishment of steam turbines  

SciTech Connect

This book reports on the proceedings of design, repair and refurbishment of steam engines. Topics covered include: Advisor/Expert Systems for Steam Turbines; Moisture Effects on the Operating and Performance of Steam Turbines; Turbine Steam Path Development; Repair and Refurbishment of the Electric Generator Components; and Advanced Steam Turbine Designs.

Warnock, A.S. (Lehigh Univ., PA (United States))

1991-01-01T23:59:59.000Z

105

Improved Criteria for the Repair of Fabrication Flaws  

SciTech Connect

Section III of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code for nuclear power plant components requires radiographic examinations (RT) of welds and requires repairs for RT indications that exceed code acceptable sizes. This paper describes research that has generated data on welding flaws, which indicated that the largest flaws occur in repaired welds. The fabrication flaws were detected in material removed from cancelled nuclear power plants using high sensitivity Nondestructive Examination (NDE) and validated by complementary NDE and destructive testing. Evidence suggests that repairs are often for small and benign RT indications at locations buried within the vessel or pipe wall. Probabilistic fracture mechanics calculations are described in this paper to predict the increases in vessel and piping failure probabilities caused by the repair-induced flaws. Calculations address failures of embrittled vessel welds for pressurized thermal shock (PTS) transients and piping failures caused by fatigue crack growth. For vessels the small flaws, which are relatively common, can cause brittle fracture, such that the rarely encountered repair flaws of large sizes gave only modestly increased failure probabilities. Calculations for piping show that only relatively large fabrication flaws can cause failures because of the ductile nature of the piping material. The large repair flaws therefore significantly increased the failure probabilities. The paper recommends the use of more discriminating ultrasonic examinations in place of RT examinations along with repair criteria based on a fitness-for-purpose approach that minimize the number of unjustified repairs.

Doctor, Steven R.; Schuster, George J.; Simonen, Fredric A.

2004-12-01T23:59:59.000Z

106

Nucleotide Excision Repair Pathway Genes and Oral Premalignant Lesions  

Science Journals Connector (OSTI)

...repair protein XPA binds replication protein A (RPA). J Biol Chem 1995;270:4152-7. 18 van Gool AJ, Citterio E, Rademakers S, et al. The Cockayne syndrome B protein, involved in transcription-coupled DNA repair, resides in an RNA polymerase...

Yunfei Wang; Margaret R. Spitz; J. Jack Lee; Maosheng Huang; Scott M. Lippman; Xifeng Wu

2007-06-15T23:59:59.000Z

107

The Cable Repair Ship H.M.T.S. Monarch  

Science Journals Connector (OSTI)

... -6), members of the general public had an opportunity of inspecting the Post Office cable repair ship Monarch, which was lying in the Thames off the Tower. This ship ... fitted out with the special gear necessary for carrying out all the operations required in cable laying and repair, on which service she is at sea for most of the ...

1934-10-06T23:59:59.000Z

108

DNA repair: Dynamic defenders against cancer and aging  

SciTech Connect

You probably weren't thinking about your body's cellular DNA repair systems the last time you sat on the beach in the bright sunshine. Fortunately, however, while you were subjecting your DNA to the harmful effects of ultraviolet light, your cells were busy repairing the damage. The idea that our genetic material could be damaged by the sun was not appreciated in the early days of molecular biology. When Watson and Crick discovered the structure of DNA in 1953 [1], it was assumed that DNA is fundamentally stable since it carries the blueprint of life. However, over 50 years of research have revealed that our DNA is under constant assault by sunlight, oxygen, radiation, various chemicals, and even our own cellular processes. Cleverly, evolution has provided our cells with a diverse set of tools to repair the damage that Mother Nature causes. DNA repair processes restore the normal nucleotide sequence and DNA structure of the genome after damage [2]. These responses are highly varied and exquisitely regulated. DNA repair mechanisms are traditionally characterized by the type of damage repaired. A large variety of chemical modifications can alter normal DNA bases and either lead to mutations or block transcription if not repaired, and three distinct pathways exist to remove base damage. Base excision repair (BER) corrects DNA base alterations that do not distort the overall structure of the DNA helix such as bases damaged by oxidation resulting from normal cellular metabolism. While BER removes single damaged bases, nucleotide excision repair (NER) removes short segments of nucleotides (called oligonucleotides) containing damaged bases. NER responds to any alteration that distorts the DNA helix and is the mechanism responsible for repairing bulky base damage caused by carcinogenic chemicals such as benzo [a]pyrene (found in cigarette smoke and automobile exhaust) as well as covalent linkages between adjacent pyrimidine bases resulting from the ultraviolet (UV) component of sunlight. NER can be divided into two classes based on where the repair occurs. NER occurring in DNA that is not undergoing transcription (i.e., most of the genome) is called global genome repair (GGR or GGNER), while NER taking place in the transcribed strand of active genes is called transcription-coupled repair (TCR or TC-NER). We will explore NER in more detail below. Mismatch repair (MMR) is another type of excision repair that specifically removes mispaired bases resulting from replication errors. DNA damage can also result in breaks in the DNA backbone, in one or both strands. Single-strand breaks (SSBs) are efficiently repaired by a mechanism that shares common features with the later steps in BER. Double-strand breaks (DSBs) are especially devastating since by definition there is no intact complementary strand to serve as a template for repair, and even one unrepaired DSB can be lethal [3]. In cells that have replicated their DNA prior to cell division, the missing information can be supplied by the duplicate copy, or sister chromatid, and DSBs in these cells are faithfully repaired by homologous recombination involving the exchange of strands of DNA between the two copies. However, most cells in the body are non-dividing, and in these cells the major mechanism for repairing DSBs is by non-homologous end joining (NHEJ), which as the name implies involves joining two broken DNA ends together without a requirement for homologous sequence and which therefore has a high potential for loss of genetic information.

Fuss, Jill O.; Cooper, Priscilla K.

2006-04-01T23:59:59.000Z

109

POSITION OPENING APPLIED STATISTICS  

E-Print Network (OSTI)

: Assistant or Associate Professor of Applied Statistics. Employment Beginning: September 16, 2012 DescriptionPOSITION OPENING APPLIED STATISTICS Department of Decision Sciences Charles H. Lundquist College at the University of Oregon is seeking to fill one tenure-track faculty position in Applied Statistics. Rank

Shepp, Larry

110

Applied quantum mechanics 1 Applied Quantum Mechanics  

E-Print Network (OSTI)

that describe the time-dependent state . If can be expressed as a power series in the perturbing potential of a one dimensional har- monic oscillator. At time t = 0 a perturbation is applied where V0-dimensional rectangular potential well for which in the range and elsewhere. It is decided to control the state

Levi, Anthony F. J.

111

DNA damage and repair in human skin in situ  

SciTech Connect

Understanding the molecular and cellular origins of sunlight-induced skin cancers in man requires knowledge of the damages inflicted on human skin during sunlight exposure, as well as the ability of cells in skin to repair or circumvent such damage. Although repair has been studied extensively in procaryotic and eucaryotic cells - including human cells in culture - there are important differences between repair by human skin cells in culture and human skin in situ: quantitative differences in rates of repair, as well as qualitative differences, including the presence or absence of repair mechanisms. Quantitation of DNA damage and repair in human skin required the development of new approaches for measuring damage at low levels in nanogram quantities of non-radioactive DNA. The method allows for analysis of multiple samples and the resulting data should be related to behavior of the DNA molecules by analytic expressions. Furthermore, it should be possible to assay a variety of lesions using the same methodology. The development of new analysis methods, new technology, and new biochemical probes for the study of DNA damage and repair are described. 28 refs., 4 figs.

Sutherland, B.M.; Gange, R.W.; Freeman, S.E.; Sutherland, J.C.

1987-01-01T23:59:59.000Z

112

Analysis of a carbon composite overwrap pipeline repair system  

Science Journals Connector (OSTI)

A relatively new method has been developed to stop external corrosion and structurally reinforce steel pipes by external wrapping of damaged sections using fibre reinforced polymer (FRP) materials. Several different defect geometries representing corrosion patches on steel pipe were characterized using finite-element analysis, by changing the circumferential length of the defect. Pipe vessels containing these defects along with the composite structural repairs were modeled and the results were compared to field tests to determine the effectiveness of the repairs. It was found that the defect width around the circumference had little impact on the ultimate rupture pressure of the repaired vessel, but influenced the stress state in the underlying pipe substrate.

J.M. Duell; J.M. Wilson; M.R. Kessler

2008-01-01T23:59:59.000Z

113

Repair-Mediated Duplication by Capture of Proximal Chromosomal DNA Has Shaped Vertebrate Genome  

E-Print Network (OSTI)

computational pipeline that takes advantage of the repetitive structure of genomes to detect repairRepair-Mediated Duplication by Capture of Proximal Chromosomal DNA Has Shaped Vertebrate Genome if not repaired promptly. Experimental systems have shown that DSB repair in eukaryotic cells is often imperfect

Feschotte, Cedric

114

Analytical Chemistry Applied Mathematics  

E-Print Network (OSTI)

Analytical Chemistry Applied Mathematics Architectural Engineering Architecture Architecture Electricity Markets Environmental Engineering Food Process Engineering Food Safety & Technology Architecture Information Technology & Management Integrated Building Delivery Landscape Architecture Management

Heller, Barbara

115

How To Apply  

NLE Websites -- All DOE Office Websites (Extended Search)

CSCEEE undergraduate students are encouraged to apply. Required Materials Current Resume Official University Transcript (with spring courses posted andor a copy of Spring...

116

A tissue engineering strategy for integrative cartilage repair  

E-Print Network (OSTI)

Tissue engineering for cartilage repair is a promising approach for improving the healing of articular defects, as biomaterials and growth factors can be supplied directly to a focal lesion. However, integrating neo-tissue ...

Mroszczyk, Keri A

2014-01-01T23:59:59.000Z

117

Repair of Damaged DNA by Arabidopsis Cell Extract  

Science Journals Connector (OSTI)

...and irradiated at the doses indicated in figure legends...the repair of a model ionizing radiation-induced DNA strand...their genomes from a wide range of genotoxic stresses...Arabidopsis cytology genetics radiation effects Cell Extracts...

Anatoliy Li; David Schuermann; Francesca Gallego; Igor Kovalchuk; Bruno Tinland

118

How Do Bacteria Repair Damage from the Sun? | Advanced Photon...  

NLE Websites -- All DOE Office Websites (Extended Search)

| Subscribe to APS Science Highlights rss feed How Do Bacteria Repair Damage from the Sun? JANUARY 22, 2014 Bookmark and Share Modeling of UvrAUvrB SAXS data. Panel A shows the...

119

Local collapse of gas pipelines under sleeve repairs  

Science Journals Connector (OSTI)

Local collapse of the pipe wall under full encirclement sleeve reinforcements is associated with breaks and blow outs that cause large gas losses and abrupt depressurisation in gas pipelines. Although these defects do not represent an imminent risk of failure, they should be eliminated because they impede the normal passage of the “instrumented pig” for internal inspection. Four failed repairs were experimentally evaluated, and the effects of different geometric factors were numerically assessed via non-linear numerical modelling of fluid flow and pipe response. All possible causes of the appearance of these defects and measures to minimise their occurrence were evaluated. The position of the repaired portion with respect to the blow out, local geometry of the repair and previous defects, and the amount of gas caught in the interstice between the pipe and the reinforcement, have an important part in the event. The measures for the prevention of this problem involve the use of fillers and improved construction of repair sleeves.

J.L Otegui; S Urquiza; A Rivas; A Trunzo

2000-01-01T23:59:59.000Z

120

DNA Damage and Repair in Translational Oncology: An Overview  

Science Journals Connector (OSTI)

...is a molecular sensor of DNA breaks that facilitates DNA repair and controls genomic stability and apoptosis. PARP inhibitors...PARP-1 inhibitor NSC 737664 entered the NCI clinical development pipeline, we initiated a program to model pharmacodynamic responses...

Eddie Reed

2010-09-15T23:59:59.000Z

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Automated Image Processing for the Analysis of DNA Repair Dynamics  

E-Print Network (OSTI)

The efficient repair of cellular DNA is essential for the maintenance and inheritance of genomic information. In order to cope with the high frequency of spontaneous and induced DNA damage, a multitude of repair mechanisms have evolved. These are enabled by a wide range of protein factors specifically recognizing different types of lesions and finally restoring the normal DNA sequence. This work focuses on the repair factor XPC (xeroderma pigmentosum complementation group C), which identifies bulky DNA lesions and initiates their removal via the nucleotide excision repair pathway. The binding of XPC to damaged DNA can be visualized in living cells by following the accumulation of a fluorescent XPC fusion at lesions induced by laser microirradiation in a fluorescence microscope. In this work, an automated image processing pipeline is presented which allows to identify and quantify the accumulation reaction without any user interaction. The image processing pipeline comprises a preprocessing stage where the ima...

Riess, Thorsten; Tomas, Martin; Ferrando-May, Elisa; Merhof, Dorit

2011-01-01T23:59:59.000Z

122

Solar Water Heating System Maintenance and Repair | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heating System Maintenance and Repair Water Heating System Maintenance and Repair Solar Water Heating System Maintenance and Repair May 30, 2012 - 2:35pm Addthis Rooftop solar water heaters need regular maintenance to operate at peak efficiency. | Photo from iStockphoto.com Rooftop solar water heaters need regular maintenance to operate at peak efficiency. | Photo from iStockphoto.com Solar energy systems require periodic inspections and routine maintenance to keep them operating efficiently. Also, from time to time, components may need repair or replacement. You should also take steps to prevent scaling, corrosion, and freezing. You might be able to handle some of the inspections and maintenance tasks on your own, but others may require a qualified technician. Ask for a cost estimate in writing before having any work done. For some systems, it may

123

Coherent testing and simulation of composite blade repair  

E-Print Network (OSTI)

COHERENT TESTING AND SIMULATION OF COMPOSITE BLADE REPAIR A Thesis by BRIAN GLENN MCNICHOLS Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE... December 1997 Major Subject: Mechanical Engineering COHERENT TESTING AND SIMULATION OF COMPOSITE BLADE REPAIR A Thesis by BRIAN GLENN MCNICHOLS Submitted to Texas A&M University In partial fulfillment of the requirements for the degree of MASTER...

McNichols, Brian Glenn

2012-06-07T23:59:59.000Z

124

Manual HVOF thermal spray repair of nickel aluminum bronze castings  

SciTech Connect

Manual high velocity oxyfuel (HVOF) thermal spray repairs were accomplished on a large nickel aluminum bronze propeller castings. The repairs were done on three different configurations of surface defects of up to 100 square inches and as deep as 90 mils. Nickel aluminum bronze alloy powder, sieve sized for the HVOF process, was sprayed. High quality, high coating density, repairs were achieved even on porous areas of the castings. Prior to performance of the repairs, a procedure was qualified in accordance with MIL-STD-1687 and a mock-up simulating the repair was produced. After HVOF spraying of the mock-up, the sprayed surface was sanded, milled, and drilled to determine how finishing of the actual castings would be done. After successful procedure qualification, the HVOF equipment was moved to the job site, metal masking was devised for the spray areas and grit blasting and manual HVOF spraying was done. Results of HVOF coating chemical analyses, bend tests, coating tensile bond strength tests, coating microscopic examinations, and mock-up evaluations are reported along with the spray procedures and techniques used in the repairs.

Brenna, R.T.; McCaw, R.L.; Pugh, J.L.

1994-12-31T23:59:59.000Z

125

Deepwater pipeline-repair system deployed to Mediterranean  

SciTech Connect

The latest phase in development of a deepwater pipeline-repair system received full-scale trials earlier this summer in Norway and has been deployed on standby for the Trans-Mediterranean pipeline by operator SNAM. In Stavanger harbor in June, Sonsub International Inc.`s Arcos diverless repair system underwent successful shallow-water trials that employed all the system`s equipment. (Arcos is an Italian acronym for attrezzaturre per la riparazione di condotte sottomarine-subsea pipe repair tooling.) The system is the most recent development in an evolution of efforts to develop a diverless pipeline-repair system for deepwater use. The prototype PRS (pipeline repair system) received deepwater (300m) trials offshore southern Italy in 1992. It used two work-class ROVs. In 1995, a modified PRS, renamed the DSRS (diverless sealine repair system), underwent shallow-water trials, also offshore southern Italy, that led to a modification of its pipe-lifting system. In 1997, the DSRS underwent more shallow-water trials, this time in Stavanger, which led to improvement in the spool-installation module. According to Sonsub, this refined version of the Arcos employs a low-force modular concept that is ROV supported and can be adapted quickly and easily to a wide range of pipe sizes.

True, W.R.

1998-11-16T23:59:59.000Z

126

Applied Energy Programs  

NLE Websites -- All DOE Office Websites (Extended Search)

Applied Energy Programs Applied Energy Programs Applied Energy Programs Los Alamos is using its world-class scientific capabilities to enhance national energy security by developing energy sources with limited environmental impact and by improving the efficiency and reliability of the energy infrastructure. CONTACT US Acting Program Director Melissa Fox (505) 663-5538 Email Applied Energy Program Office serves as the hub connecting the Laboratory's scientific and technical resources to DOE sponsors, DoD programs, and to industry. The Applied Energy Program Office manages Los Alamos National Laboratory programs funded by the Department of Energy's (DOE's) Offices of Energy Efficiency/Renewable Energy, Electricity Delivery and Energy Reliability, and Fossil Energy. With energy use increasing across the nation and the

127

AEROSPACE SCIENCES Applied aerodynamics  

E-Print Network (OSTI)

AEROSPACE SCIENCES Applied aerodynamics This year saw significant progress in industry, research labs, and academia in the development of flow-control concepts, novel configuration aerodynamic concepts, and aerodynamic im- provement technologies for enhancing the fuel efficiency and performance

Xu, Kun

128

Applied large eddy simulation  

Science Journals Connector (OSTI)

...2971-2983. doi:10.1098/rsta.2008.0303 . Audio Supplement Audio Supplement Audio files from the Applied large eddy simulation...fidelity. | Whittle Laboratory, Department of Engineering, University of Cambridge, Cambridge CB2 1PZ...

2009-01-01T23:59:59.000Z

129

Applied Science/Techniques  

NLE Websites -- All DOE Office Websites (Extended Search)

Applied Science/Techniques Applied Science/Techniques Applied Science/Techniques Print The ALS is an excellent incubator of new scientific techniques and instrumentation. Many of the technical advances that make the ALS a world-class soft x-ray facility are developed at the ALS itself. The optical components in use at the ALS-mirrors and lenses optimized for x-ray wavelengths-require incredibly high-precision surfaces and patterns (often formed through extreme ultraviolet lithography at the ALS) and must undergo rigorous calibration and testing provided by beamlines and equipment from the ALS's Optical Metrology Lab and Berkeley Lab's Center for X-Ray Optics. New and/or continuously improved experimental techniques are also a crucial element of a thriving scientific facility. At the ALS, examples of such "technique" highlights include developments in lensless imaging, soft x-ray tomography, high-throughput protein analysis, and high-power coherent terahertz radiation.

130

Information Science, Computing, Applied Math  

NLE Websites -- All DOE Office Websites (Extended Search)

Capabilities ISC Applied Math science-innovationassetsimagesicon-science.jpg Information Science, Computing, Applied Math National security depends on science and...

131

Simple Maintenance Saves Costly Furnace Repair/Replacement | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Simple Maintenance Saves Costly Furnace Repair/Replacement Simple Maintenance Saves Costly Furnace Repair/Replacement Simple Maintenance Saves Costly Furnace Repair/Replacement January 6, 2010 - 8:26am Addthis Chris Stewart Senior Communicator at DOE's National Renewable Energy Laboratory For the past few weeks, my forced-air gas furnace has been on the fritz. I blame this on the fact that I haven't been as diligent as I should have been with regular furnace maintenance, which includes: Checking the condition of the vent connection pipe and chimney Checking the physical integrity of the heat exchanger Adjusting the controls to provide optimum water and air temperature settings for both efficiency and comfort Having a technician perform a combustion-efficiency test Checking the combustion chamber for cracks. Testing for carbon monoxide

132

The repair and rehabilitation method of Tokyo gas  

SciTech Connect

It has been an important matter for gas utilities to maintain their pipelines easily and economically. But pipes that have become old suffer from progressive corrosion, and as a result of vibration caused by traffic or the effects of land subsidence, joints can become loosened. To repair pipes that have suffered in such ways, the usual method to do is to dig them up and replace them with new ones. But this method requires a large amount of excavation, so the work takes a long time to complete and is costly. To deal with these problems, Tokyo Gas developed number of repair and rehabilitation methods to permit renewal of pipelines without replacing them. In this paper, I would like to introduce our repair and rehabilitation methods for low-pressure pipeline. 4 refs., 9 figs., 4 tabs.

Yagi, Shuichi [Tokyo Gas Co., Ltd. (Japan)

1996-08-01T23:59:59.000Z

133

Additive manufacturing for in situ repair of osteochondral defects  

Science Journals Connector (OSTI)

Tissue engineering holds great promise for injury repair and replacement of defective body parts. While a number of techniques exist for creating living biological constructs in vitro, none have been demonstrated for in situ repair. Using novel geometric feedback-based approaches and through development of appropriate printing-material combinations, we demonstrate the in situ repair of both chondral and osteochondral defects that mimic naturally occurring pathologies. A calf femur was mounted in a custom jig and held within a robocasting-based additive manufacturing (AM) system. Two defects were induced: one a cartilage-only representation of a grade IV chondral lesion and the other a two-material bone and cartilage fracture of the femoral condyle. Alginate hydrogel was used for the repair of cartilage; a novel formulation of demineralized bone matrix was used for bone repair. Repair prints for both defects had mean surface errors less than 0.1 mm. For the chondral defect, 42.8 ± 2.6% of the surface points had errors that were within a clinically acceptable error range; however, with 1 mm path planning shift, an estimated ~75% of surface points could likely fall within the benchmark envelope. For the osteochondral defect, 83.6 ± 2.7% of surface points had errors that were within clinically acceptable limits. In addition to implications for minimally invasive AM-based clinical treatments, these proof-of-concept prints are some of the only in situ demonstrations to-date, wherein the substrate geometry was unknown a priori. The work presented herein demonstrates in situ AM, suggests potential biomedical applications and also explores in situ-specific issues, including geometric feedback, material selection and novel path planning techniques.

Daniel L Cohen; Jeffrey I Lipton; Lawrence J Bonassar; Hod Lipson

2010-01-01T23:59:59.000Z

134

SUSTAINABILITY WHO CAN APPLY  

E-Print Network (OSTI)

FUNDED BY CALL FOR SUSTAINABILITY RESEARCH STUDENT WHO CAN APPLY Undergraduate and graduate Participate in the Global Change & Sustainability Center's Research Symposium; attend workshops with faculty or publish in the U's student-run sustainability publication to be released in May 2014. Are you conducting

135

Repairs for damaged bolt holes in continuous fiber reinforced plastics  

E-Print Network (OSTI)

repair method for damaged bolt holes in such composites. Bolt holes in three types of graphite-epoxy were purposely damaged and then repaired. Each was tested to characterize its static and fatigue behavior. The tests used a special fixture to simulate... composite joints . Bearing-bypass ratio can change the failure mode of bolted composite joints 7 Drilling defects in graphite-epoxy coupons 12 26 The exit side of a IM7/8551-7A 18 ply tape coupon showing the damage due to drilling 27 9 Resin filled...

Copps, Kevin Daniel

2012-06-07T23:59:59.000Z

136

Ice plug employed on subsea pipeline bend during repair  

SciTech Connect

The first controlled-temperature ice plug in the bend of an offshore gas trunkline has been carried out for Phillips Petroleum Co. Norway on its Norpipe A.S. platform in the German sector of the North Sea. The procedure was part of a subsea valve repair operation. The ice plug was successfully formed offshore and tested to a differential pressure of 1,450 psi. Repair of two valves required only 5 days during which time gas production was operating at close to 50--60% via the platform bypass, says the service company. The paper discusses the procedure.

NONE

1997-12-22T23:59:59.000Z

137

Polymorphisms in DNA repair genes and risk of non-Hodgkin lymphoma among women in Connecticut  

Science Journals Connector (OSTI)

Several hereditary syndromes characterized by defective DNA repair are associated with high risk of non-Hodgkin lymphoma (NHL). To explore whether common polymorphisms in DNA repair genes affect risk of NHL in th...

Min Shen; Tongzhang Zheng; Qing Lan; Yawei Zhang; Shelia H. Zahm…

2006-07-01T23:59:59.000Z

138

Subsea Repair of Concrete Weight Coating on 30? North Sea Pipeline  

Science Journals Connector (OSTI)

The 30? North Sea Gas Pipeline in the Danish sector had suffered damage ... trawlboards and other heavy fishing gear. To repair this damage several methods of repair were considered to find one which could ... pr...

Erik Reker

1991-01-01T23:59:59.000Z

139

Categorical Exclusion Determinations: South Carolina | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

December 7, 2012 December 7, 2012 CX-009604: Categorical Exclusion Determination 704-56H Sanitary Sewer Upgrade CX(s) Applied: B1.3 Date: 12/07/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office December 7, 2012 CX-009603: Categorical Exclusion Determination 716-N Yard Sinkhole Repair CX(s) Applied: B1.3 Date: 12/07/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office December 7, 2012 CX-009602: Categorical Exclusion Determination 735-A, D-112, -113, and -114 Laboratory Renovations CX(s) Applied: B2.5 Date: 12/07/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office December 7, 2012 CX-009601: Categorical Exclusion Determination Installation of a High Flux Thermal Neutron Source CX(s) Applied: B2.5 Date: 12/07/2012

140

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

June 27, 2012 June 27, 2012 CX-008614: Categorical Exclusion Determination Repair Culvert on Road 3 CX(s) Applied: B1.3 Date: 06/27/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office June 27, 2012 CX-008613: Categorical Exclusion Determination Replace Awning, Building 735-A CX(s) Applied: B1.3 Date: 06/27/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office June 26, 2012 CX-008618: Categorical Exclusion Determination Evaluation of Sorbent/Ion Exchangers for Radiochemical and Metal Separations CX(s) Applied: B3.6 Date: 06/26/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office June 26, 2012 CX-008617: Categorical Exclusion Determination Savannah River National Laboratory Building 735-13A Power Addition CX(s) Applied: B1.15

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Categorical Exclusion Determinations: South Carolina | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3, 2012 3, 2012 CX-009085: Categorical Exclusion Determination High Activity Waste Tank (HAWT) Disposition CX(s) Applied: B3.1 Date: 07/03/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office June 27, 2012 CX-008614: Categorical Exclusion Determination Repair Culvert on Road 3 CX(s) Applied: B1.3 Date: 06/27/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office June 27, 2012 CX-008613: Categorical Exclusion Determination Replace Awning, Building 735-A CX(s) Applied: B1.3 Date: 06/27/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office June 26, 2012 CX-008618: Categorical Exclusion Determination Evaluation of Sorbent/Ion Exchangers for Radiochemical and Metal Separations CX(s) Applied: B3.6 Date: 06/26/2012

142

Minimum thickness for circumferential sleeve repair fillet welds in corroded gas pipelines  

Science Journals Connector (OSTI)

The minimum weldable pipe wall thickness for sleeve repair welds is numerically assessed in this work, as a function of pressure during the welding operations of a corroded gas pipeline, according to the approach by Battelle. The minimum weldable thickness is found to increase when the flow rate of the transported gas in the section being repaired increases. Integrity of the repairs is assessed, and alternative measures to momentarily increase the flow in the area of the repair are evaluated.

A.P Cisilino; M.D Chapetti; J.L Otegui

2002-01-01T23:59:59.000Z

143

Remote Connection Systems for Subsea Pipeline Tie-Ins and Repairs  

Science Journals Connector (OSTI)

The MORGRIP coupling has been used on applications both Topside and for subsea pipeline tie ins and repairs.

Derek Cruickshank; Phil Maxted

1994-01-01T23:59:59.000Z

144

Applied Science/Techniques  

NLE Websites -- All DOE Office Websites (Extended Search)

Applied Science/Techniques Print Applied Science/Techniques Print The ALS is an excellent incubator of new scientific techniques and instrumentation. Many of the technical advances that make the ALS a world-class soft x-ray facility are developed at the ALS itself. The optical components in use at the ALS-mirrors and lenses optimized for x-ray wavelengths-require incredibly high-precision surfaces and patterns (often formed through extreme ultraviolet lithography at the ALS) and must undergo rigorous calibration and testing provided by beamlines and equipment from the ALS's Optical Metrology Lab and Berkeley Lab's Center for X-Ray Optics. New and/or continuously improved experimental techniques are also a crucial element of a thriving scientific facility. At the ALS, examples of such "technique" highlights include developments in lensless imaging, soft x-ray tomography, high-throughput protein analysis, and high-power coherent terahertz radiation.

145

Reduced COX-2 Protein in Colorectal Cancer with Defective Mismatch Repair  

Science Journals Connector (OSTI)

...Protein in Colorectal Cancer with Defective Mismatch Repair 1 1 This work...typic characteristics of defective DNA mismatch repair express...may arise in the setting of defective DNA mismatch repair. INTRODUCTION...sporadic colorectal adenomas and car cinomas (6-7) and in FAP...

William E. Karnes, Jr.; Rebecca Shattuck-Brandt; Lawrence J. Burgart; Raymond N. DuBois; David J. Tester; Julie M. Cunningham; Cheong-Yong Kim; Shannon K. McDonnell; Daniel J. Schaid; and Stephen N. Thibodeau

1998-12-01T23:59:59.000Z

146

Repair of UV Dimers in Skin DNA of Patients with Basal Cell Carcinoma  

Science Journals Connector (OSTI)

...carcinoma have a reduced capacity to repair UV-induced...after a brief exposure to solar-simulated UV radiation...Therefore, a reduced capacity to repair photolesions...induced in human skin by solar-simulating UV radiation...Grossman L. DNA repair capacity for ultraviolet light-induced...

Dan Segerbäck; Malgorzata Strozyk; Erna Snellman; and Kari Hemminki

2008-09-01T23:59:59.000Z

147

Development and Field-Test Validation of an Assay for DNA Repair in Circulating Human Lymphocytes  

Science Journals Connector (OSTI)

...as a result of the reduced capacity of patients' cells to repair...Since the UV component of solar radiation exists as the predominant...study. orientation of reduced capacity for DNA repair of UV-irradi...of estrus on the DNA repair capacity of these subjects. The effect...

William F. Athas; Mohammad A. Hedayati; Genevieve M. Matanoski; Evan R. Farmer; and Lawrence Grossman

1991-11-01T23:59:59.000Z

148

Inhibition of Short Patch and Long Patch Base Excision Repair by an Oxidized Abasic Site  

Science Journals Connector (OSTI)

Inhibition of Short Patch and Long Patch Base Excision Repair by an Oxidized Abasic Site ... Inhibition of DNA polymerase ?’s lyase function is accompanied by inactivation of its DNA polymerase activity as well, which prevents long patch base excision repair of DOB. ... Overall, DOB is highly refractory to short patch and long patch base excision repair. ...

Lirui Guan; Katarzyna Bebenek; Thomas A. Kunkel; Marc M. Greenberg

2010-10-20T23:59:59.000Z

149

Proteogenomic Analysis Reveals Unanticipated Adaptations of Colorectal Tumor Cells to Deficiencies in DNA Mismatch Repair  

Science Journals Connector (OSTI)

...related double-strand break repair protein NBN, which are constituents...decreased DNA synthesis and repair in MMR- cells (Fig. 4...application of our newly developed pipeline for the detection of variant...in DNA and RNA synthesis and repair. The driving proteins behind...

Patrick J. Halvey; Xiaojing Wang; Jing Wang; Ajaz A. Bhat; Punita Dhawan; Ming Li; Bing Zhang; Daniel C. Liebler; and Robbert J.C. Slebos

2014-01-01T23:59:59.000Z

150

Epigenetic Modifications in Double-Strand Break DNA Damage Signaling and Repair  

Science Journals Connector (OSTI)

...Focus 10 14 31 DNA Damage and Repair in Translational Oncology...investigators, DNA damage and repair has been a major focus of anticancer...Plummer R . Perspective on the pipeline of drugs being developed with...break DNA damage signaling and repair. Clin Cancer Res 2010;16...

Dorine Rossetto; Andrew W. Truman; Stephen J. Kron; and Jacques Côté

2010-09-15T23:59:59.000Z

151

“Contextual” Synthetic Lethality and/or Loss of Heterozygosity: Tumor Hypoxia and Modification of DNA Repair  

Science Journals Connector (OSTI)

...Break DNA Damage Signaling and Repair Dorine Rossetto 1 Andrew W...machineries for chromosomal DNA repair. Genes Dev 2004;18:602-16...Plummer R . Perspective on the pipeline of drugs being developed with...hypoxia and modification of DNA repair. Clin Cancer Res 2010;16...

Norman Chan and Robert G. Bristow

2010-09-15T23:59:59.000Z

152

Microsoft Word - CX-IndianCabinRoadRepair_PPA1908_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

United States Government Department of Energy United States Government Department of Energy Bonneville Power Administration DATE: June 22, 2011 REPLY TO ATTN OF: KEP-4 SUBJECT: Environmental Clearance Memorandum Elizabeth Johnson Natural Resource Specialist - TFBV-THE DALLES Proposed Action: Indian Cabin Road Repair PP&A Project No.: 1908 Categorical Exclusions Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3, Routine maintenance activities...for structures, rights of way, infrastructures such as roads, equipment... routine maintenance activities, corrective....are required to maintain...infrastructures...in a condition suitable for a facility to be used for its designated purpose. Location: The project is located in Skamania County, Washington, T3N, R8E, Sections 27

153

Corrosion Repair and Corrosion Protection of Reinforced Concrete Structures in  

E-Print Network (OSTI)

11/14/2014 1 Corrosion Repair and Corrosion Protection of Reinforced Concrete Structures in Pulp and Paper Mills Vector Construction / Vector Corrosion Technologies www.vectorgroup.com www.vector-corrosion.com Presentation Outline · Introduction · Corrosion of Reinforced Concrete Structures · Protection of Chests

Das, Suman

154

HOW TO REPAIR A SECOND-ORDER SURFACE FOR COMPUTER  

E-Print Network (OSTI)

1 HOW TO REPAIR A SECOND-ORDER SURFACE FOR COMPUTER EXPERIMENTS BY KRIGING Astrid JOURDAN and analysis of computer experiments have been widely investigated in the past decade. Two approaches seem describes and compares them briefly in order to present a methodology for computer experiments based

Paris-Sud XI, Université de

155

Workshop Proceedings: Life Assessment and Repair of Steam Turbine Casings  

SciTech Connect

With the trend toward operating steam turbines far beyond their design lives, utilities need methods for assessing and extending the lives of the turbine casings. Consolidating and publishing industry experience on this subject will help utilities make run/replace decisions, select appropriate repair techniques, implement operational changes, and select new designs to meet future needs.

None

1986-07-01T23:59:59.000Z

156

Development/Plasticity/Repair Identification of Nicotinic Acetylcholine Receptor Recycling  

E-Print Network (OSTI)

Development/Plasticity/Repair Identification of Nicotinic Acetylcholine Receptor Recycling and Its, University of Michigan, Ann Arbor, Michigan 48109 In the CNS, receptor recycling is critical for synaptic plasticity; however, the recycling of receptors has never been observed at peripheral synapses. Using a novel

Alford, Simon

157

USDA Grants to Help Repair Housing in Rural Areas  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Agriculture (USDA) is accepting applications for the Housing Preservation Grant program, which provides funding to repair low-income housing, rental properties, or co-op owned housing. Eligible sponsors include state agencies, local government, Tribes, and nonprofits.

158

DNA Damage Repair Pathways in Cancer Stem Cells  

Science Journals Connector (OSTI)

...reads to the genome was performed using the AB BioScope 1.2 Pipeline and outputs imported into Partek Genomics Suite for analysis...results reveals upregulation of genes and miRNAs involved in DNA repair, angiogenesis, and inhibitors of Estrogen Receptor-alpha...

Marcello Maugeri-Saccà; Monica Bartucci; and Ruggero De Maria

2012-08-01T23:59:59.000Z

159

Thermosetting Polymer-Matrix Composites for Strucutral Repair Applications  

SciTech Connect

Several classes of thermosetting polymer matrix composites were evaluated for use in structural repair applications. Initial work involved the characterization and evaluation of woven carbon fiber/epoxy matrix composites for structural pipeline repair. Cyanate ester resins were evaluated as a replacement for epoxy in composites for high-temperature pipe repair applications, and as the basis for adhesives for resin infusion repair of high-temperature composite materials. Carbon fiber/cyanate ester matrix composites and fumed silica/cyanate ester nanocomposites were evaluated for their thermal, mechanical, viscoelastic, and rheological properties as they relate to their structure, chemistry, and processing characteristics. The bisphenol E cyanate ester under investigation possesses a high glass transition temperature, excellent mechanical properties, and unique ambient temperature processability. The incorporate of fumed silica served to enhance the mechanical and rheological properties of the polymer and reduce thermal expansion without sacrificing glass transition or drastically altering curing kinetics. Characterization of the composites included dynamic mechanical analysis, thermomechanical analysis, differential scanning calorimetry, thermogravimetric analysis, rheological and rheokinetic evaluation, and transmission electron microscopy.

William Kirby Goertzen

2007-12-01T23:59:59.000Z

160

Applied ALARA techniques  

SciTech Connect

The presentation focuses on some of the time-proven and new technologies being used to accomplish radiological work. These techniques can be applied at nuclear facilities to reduce radiation doses and protect the environment. The last reactor plants and processing facilities were shutdown and Hanford was given a new mission to put the facilities in a safe condition, decontaminate, and prepare them for decommissioning. The skills that were necessary to operate these facilities were different than the skills needed today to clean up Hanford. Workers were not familiar with many of the tools, equipment, and materials needed to accomplish:the new mission, which includes clean up of contaminated areas in and around all the facilities, recovery of reactor fuel from spent fuel pools, and the removal of millions of gallons of highly radioactive waste from 177 underground tanks. In addition, this work has to be done with a reduced number of workers and a smaller budget. At Hanford, facilities contain a myriad of radioactive isotopes that are 2048 located inside plant systems, underground tanks, and the soil. As cleanup work at Hanford began, it became obvious early that in order to get workers to apply ALARA and use hew tools and equipment to accomplish the radiological work it was necessary to plan the work in advance and get radiological control and/or ALARA committee personnel involved early in the planning process. Emphasis was placed on applying,ALARA techniques to reduce dose, limit contamination spread and minimize the amount of radioactive waste generated. Progress on the cleanup has,b6en steady and Hanford workers have learned to use different types of engineered controls and ALARA techniques to perform radiological work. The purpose of this presentation is to share the lessons learned on how Hanford is accomplishing radiological work.

Waggoner, L.O.

1998-02-05T23:59:59.000Z

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

for Applied Linguistics.  

E-Print Network (OSTI)

per calendar year, promptly at intervals of three months. Each pack is to contain two numbers of the Finite String. The difficulties of the first year of publication of AJCL are responsible for the d'elayed, production of this ~ack, which also contains Volume 11, Number 4 of TFS. ~k would be a rash editor indeed who guaranteed promptness without caveat. The present editbr must warn the subscriber that'the end of the diLf.iculti-es is not yet fixed for a date certa.in. AMERICAN JQURNAL OF COMPL'TATIONAL LINGUISTICS is published by the Center for Applied Linguistics for the Association for Computational Linguistics.

Assistant Nancy Jokovl Ch

162

Modelling repairable system reliability with explanatory variables and repair and maintenance actions  

Science Journals Connector (OSTI)

......time (such as operating hours, fuel consumption, etc) does not already represent...a case study applied to diesel engine control. Microelectron. Reliab...Proportional hazards analysis of diesel engine failure data. Qual. Reliab......

Diederik Lugtigheid; agan Banjevic; Andrew K. S. Jardine

2004-04-01T23:59:59.000Z

163

Modelling repairable system reliability with explanatory variables and repair and maintenance actions  

Science Journals Connector (OSTI)

......time (such as operating hours, fuel consumption, etc) does not already represent...electronics: a case study applied to diesel engine control. Microelectron. Reliab...Proportional hazards analysis of diesel engine failure data. Qual. Reliab......

Diederik Lugtigheid; agan Banjevic; Andrew K. S. Jardine

2004-04-01T23:59:59.000Z

164

Applied Optoelectronics | Open Energy Information  

Open Energy Info (EERE)

Optoelectronics Jump to: navigation, search Name: Applied Optoelectronics Place: Sugar Land, Texas Zip: 77478 Product: Applied Optoelectronics designs, develops, and manufactures...

165

ORISE: Applied health physics projects  

NLE Websites -- All DOE Office Websites (Extended Search)

Applied health physics projects The Oak Ridge Institute for Science and Education (ORISE) provides applied health physics services to government agencies needing technical support...

166

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

51 - 20360 of 26,764 results. 51 - 20360 of 26,764 results. Download CX-006723: Categorical Exclusion Determination Repair Flowline 77-S-10 CX(s) Applied: B2.5, B5.2, B5.4 Date: 03/12/2010 Location(s): Casper, Wyoming Office(s): RMOTC http://energy.gov/nepa/downloads/cx-006723-categorical-exclusion-determination Download CX-006722: Categorical Exclusion Determination Repair Flowline 61-66-SX-3 CX(s) Applied: B5.2, B5.4 Date: 03/16/2010 Location(s): Casper, Wyoming Office(s): RMOTC http://energy.gov/nepa/downloads/cx-006722-categorical-exclusion-determination Download CX-006700: Categorical Exclusion Determination Geothermal Technologies Program CX(s) Applied: B5.1 Date: 11/18/2010 Location(s): Casper, Wyoming Office(s): RMOTC http://energy.gov/nepa/downloads/cx-006700-categorical-exclusion-determination

167

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3, 2012 3, 2012 CX-008950: Categorical Exclusion Determination Pilot Testing: Pretreatment Options to Allow Re-Use of Frac Flowback Water CX(s) Applied: B3.6 Date: 08/13/2012 Location(s): Pennsylvania Offices(s): National Energy Technology Laboratory August 13, 2012 CX-008949: Categorical Exclusion Determination Novel Materials for Robust Repair of Leaky Wellbores in Carbon Dioxide Storage Formations CX(s) Applied: A9, B3.6 Date: 08/13/2012 Location(s): Texas Offices(s): National Energy Technology Laboratory August 13, 2012 CX-008884: Categorical Exclusion Determination Rattlesnake Butte Property Funding CX(s) Applied: B1.25 Date: 08/13/2012 Location(s): Oregon Offices(s): Bonneville Power Administration August 13, 2012 CX-008879: Categorical Exclusion Determination Pearl-Marion No.1 Line Tower 21/1 Bank Repair Project

168

Categorical Exclusion Determinations: Environmental Management | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

March 18, 2010 March 18, 2010 CX-001366: Categorical Exclusion Determination Repair Roof Leaks in L Reactor Building CX(s) Applied: B1.3 Date: 03/18/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office March 18, 2010 CX-001365: Categorical Exclusion Determination Repair Domestic Water Line Near Entrance to 717-F CX(s) Applied: B1.3 Date: 03/18/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office March 16, 2010 CX-001371: Categorical Exclusion Determination Synthetic Concentrators CX(s) Applied: B3.6 Date: 03/16/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office March 16, 2010 CX-001370: Categorical Exclusion Determination

169

Categorical Exclusion Determinations: National Energy Technology Laboratory  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

30, 2010 30, 2010 CX-004106: Categorical Exclusion Determination Green Oil: Carbon Dioxide Enhanced Oil Recovery for America?s Small Oil Producers CX(s) Applied: A9 Date: 09/30/2010 Location(s): Socorro, New Mexico Office(s): Fossil Energy, National Energy Technology Laboratory September 30, 2010 CX-004105: Categorical Exclusion Determination High Resolution Three-Dimensional Laser Imaging for Inspection, Maintenance, Repair and Operations CX(s) Applied: B3.6 Date: 09/30/2010 Location(s): Houston, Texas Office(s): Fossil Energy, National Energy Technology Laboratory September 30, 2010 CX-004100: Categorical Exclusion Determination High Resolution Three-Dimensional Laser Imaging for Inspection, Maintenance, Repair and Operations CX(s) Applied: B3.6 Date: 09/30/2010 Location(s): Boulder, Colorado

170

Categorical Exclusion Determinations: B1.3 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

June 20, 2013 June 20, 2013 CX-010551: Categorical Exclusion Determination Alcova-Miracle Mile East 115 Kilovolt Transmission Line Structure Replace and Road Maintenance, Carbon and Natrona Counties, Wyoming CX(s) Applied: B1.3 Date: 06/20/2013 Location(s): Wyoming, Wyoming Offices(s): Western Area Power Administration-Rocky Mountain Region June 20, 2013 CX-010655: Categorical Exclusion Determination Roof Repair on Crane Maintenance Area Roof CX(s) Applied: B1.3 Date: 06/20/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office June 18, 2013 CX-010656: Categorical Exclusion Determination Stormwater Drainage Repair CX(s) Applied: B1.3 Date: 06/18/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office June 17, 2013 CX-010662: Categorical Exclusion Determination

171

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

30, 2010 30, 2010 CX-004105: Categorical Exclusion Determination High Resolution Three-Dimensional Laser Imaging for Inspection, Maintenance, Repair and Operations CX(s) Applied: B3.6 Date: 09/30/2010 Location(s): Houston, Texas Office(s): Fossil Energy, National Energy Technology Laboratory September 30, 2010 CX-004100: Categorical Exclusion Determination High Resolution Three-Dimensional Laser Imaging for Inspection, Maintenance, Repair and Operations CX(s) Applied: B3.6 Date: 09/30/2010 Location(s): Boulder, Colorado Office(s): Fossil Energy, National Energy Technology Laboratory September 30, 2010 CX-004099: Categorical Exclusion Determination Advanced Energy Efficient Building Technologies for High Performance Hospitals CX(s) Applied: A9 Date: 09/30/2010 Location(s): Eugene, Oregon

172

Solar Cells, Wound Repair Winning GVC Technologies | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Solar Cells, Wound Repair Winning GVC Technologies Solar Cells, Wound Repair Winning GVC Technologies March 26, 2010 Graduate student teams from the University of Arkansas and the University of Maryland earned first place in the energy and security categories at the 2010 GVC hosted by ORNL March 24-26. The competition, in its fourth year, attracts students developing new technologies and venture investors with expertise in the market. The first-prize winners each received $25,000. Douglas Hutchings, Stephen Ritterbush, and Seth Shumate from Arkansas won first place in the energy division for Silicon Solar Solutions. "Our method replaces the expensive top layer of solar cells with a thinner, large-grain polysilicon at lower temperatures, which reduces cost and is appealing to manufacturers," said Ritterbush.

173

Freeze plug proves safe, economical in riser repair  

SciTech Connect

In October 1992, Exxon Pipeline Co., Houston, performed in the Gulf of Mexico what the company believes to have been the first underwater freeze-plug procedure. To form a plug, water in a small section of the pipe is frozen with liquid nitrogen. In partially replacing a 10-in. riser at South Marsh Island Block 6A, Exxon Pipeline worked closely with a freeze-plug service company to minimize environmental and personnel exposure and to avoid the chance of an oil spill. The freeze plug reduced the time the pipe was open-ended during the repair, and hydrotesting the freeze plug area and repair section ensured integrity. The paper describes onshore testing of the procedures, pre-work surface cleaning, and the freeze-plug procedure.

Nelson, M.J. [Exxon Co. U.S.A., New Orleans, LA (United States)

1995-05-01T23:59:59.000Z

174

Chapter 32 - Cellular Signaling in Dentin Repair and Regeneration  

Science Journals Connector (OSTI)

Abstract Injury to the dentin-pulp complex results in a variety of cellular responses that determine tooth vitality and survival. Initially, these responses center on the odontoblasts as the first line of defense and environmental sensors, but will subsequently encompass other cells in the pulp with a complex interplay being seen between regenerative responses involving odontoblasts and the inflammation associated with pulpal responses to injury. Local degradation of dentin matrix following injury will release bioactive molecules contributing to cellular signaling. While tissue repair and regeneration will likely occur only when infection and inflammation are under control, low-level cytokine stimulation during the earlier stages of dental disease, and possibly as resolution of inflammation ensues, may facilitate and promote reparative events. Whether odontoblasts survive the injurious challenge will determine if reactionary or reparative dentinogenesis occurs during repair and regeneration in the dentin-pulp complex. Notably the complexity of cellular responses is significantly greater for reparative dentinogenesis where stem/progenitor cell recruitment and induction of differentiation are required prior to up-regulation of cellular secretion of new matrix. Angiogeneic and neurogenic signaling are also important events during repair and regeneration. Improved understanding of cellular signaling following tooth injury helps underpin our approaches to diagnosis and treatment planning, as well as driving novel strategies for translation of new clinical therapeutic approaches.

Anthony (Tony) J. Smith; Paul R. Cooper

2015-01-01T23:59:59.000Z

175

Managed operation and repair of a deteriorating large diameter pipeline  

SciTech Connect

Since 1986, Brandon Shores Generating Station has successfully managed a recurring maintenance problem with the buried prestressed concrete cylinder pipe (PCCP) of its circulating water system. It is the intent of this paper to provide a history of the plant`s approach to safely operating and maintaining the deteriorating pipe of this system. This paper will briefly discuss the results of failure analysis performed on the ruptured pipe. Findings of engineering studies addressing the structural integrity of the remaining pipeline will be discussed. The inspection methodology used at Brandon Shores to periodically assess the pipe will be described. Several methods of pipe repair, both external and internal will be detailed. Particular focus will be placed on an internal repair design successfully implemented on two pipe sections during a 1993 plant outage. This internal repair resulted in no loss of hydraulic section, and was erected in-place using conventional materials which were entirely transported through 36 inch manholes. The pipeline was placed back in service and has performed satisfactorily to date.

Cramblitt, K.L. [Baltimore Gas and Electric Company, Baltimore, MD (United States); Lawson, T.J. [Construction Technology Laboratories Inc., Skokie, IL (United States); Ciolko, A.T. [Construction Technology Labs. Inc., Skokie, IL (United States)

1996-07-01T23:59:59.000Z

176

CX-012090: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Henderson-Mead Number 2 230-Kilovolt Transmission Line, Erosion Repair at Structure 2/4 CX(s) Applied: B1.3 Date: 09/11/2013 Location(s): Nevada, Nevada Offices(s): Western Area Power Administration-Desert Southwest Region

177

CX-011232: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Gore Pass-Hayden 138 Kilovolt Transmission Line Emergency Repairs of Downed Conductor Grand County, Colorado CX(s) Applied: B1.3 Date: 10/09/2013 Location(s): Colorado Offices(s): Western Area Power Administration-Rocky Mountain Region

178

CX-100021: Categorical Exclusion Determination  

Office of Energy Efficiency and Renewable Energy (EERE)

National Wind Technology Center Road Repairs; NREL Tracking No. 14-016 CX(s) Applied: DOE/EA-1914 Date: 09/03/2014 Location(s): Colorado Offices(s): Golden Field Office Technology Office: National Renewable Energy Laboratory Award Number: DE-AC36-08GO28308

179

CX-012352: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Flaming Gorge Microwave Site Communications Building Access Road Repairs, Daggett County, Utah (Amended) CX(s) Applied: B1.3 Date: 06/03/2014 Location(s): Utah Offices(s): Western Area Power Administration-Rocky Mountain Region

180

School of Applied Technology School of Applied Technology  

E-Print Network (OSTI)

School of Applied Technology School of Applied Technology Daniel F. and Ada L. Rice Campus Illinois Institute of Technology 201 E. Loop Road Wheaton, IL 60187 630.682.6000 www.iit.edu/applied tech/ Dean and Academic Director, Information Technology and Management Programs: C. Robert Carlson Director of Operations

Heller, Barbara

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

School of Applied Technology School of Applied Technology  

E-Print Network (OSTI)

School of Applied Technology School of Applied Technology Daniel F. and Ada L. Rice Campus Illinois Institute of Technology 201 E. Loop Road Wheaton, IL 60187 630.682.6000 www.iit.edu/applied tech/ Dean Technology and Management Programs: Mazin Safar Director, Marketing & Development: Scott Pfeiffer Director

Heller, Barbara

182

One "Cool Tool" That's Helping Repair Your DNA | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

"Cool Tool" That's Helping Repair Your DNA "Cool Tool" That's Helping Repair Your DNA One "Cool Tool" That's Helping Repair Your DNA April 18, 2011 - 1:20pm Addthis Charles Rousseaux Charles Rousseaux Senior Writer, Office of Science What are the key facts? Berkeley Lab's Advanced Light Source produces x-ray light that shines a billion times bright than the sun. Scientists discovered the motor that drives the actual repair of the DNA repair machine called MRN, which is tethered to the rest of the machine in a fairly flexible fashion. Further insight into MRN and other DNA repair machines may also give scientists new insights into fighting some cancers as well as other diseases such as cystic fibrosis. With the arrival of spring, many families are dusting off their tools to make some home improvements. It's worth remembering that nature also has

183

Multi-criteria decision model for selecting repair contracts by applying utility theory and variable interdependent parameters  

Science Journals Connector (OSTI)

......environments, by seeking to establish exemplary standards in order to attain a MULTI-CRITERIA...essential activities at a world-class standard. Organizations have, therefore, to...T. M. (2003) An analysis on the HVAC maintenance contractors selection process......

Anderson Jorge de Melo Brito; Adiel Teixeira de Almeida Filho; Adiel Teixeira de Almeida

2010-10-01T23:59:59.000Z

184

Significance of changes in residual stresses and mechanical properties due to SMAW repair of girth welds in linepipe  

SciTech Connect

This program assessed the effects of SMAW repair welding on changes in surface residual stress distribution, fracture toughness and hardness around girth weld joints in linepipe. The following types of repair welds were studied: a part wall repair, a multiple part wall repair and full wall repair. The results were compared with a non-repaired weld sample. It was found that for the weld samples studied in this program, the full wall repair produced the most severe residual stress distribution followed by the multiple and single part wall repairs. The single repair only slightly increased the residual stress distribution when compared to the as-welded condition. Dramatic reductions in toughness were found in the multiple and full repairs due to coarse-grained regions produced during the repair operations. The single part wall repair exhibited an increase in toughness as a result of the addition of a cosmetic capping pass which resulted in greater grain refinement. This suggests that repair procedures utilizing a stringer or temper bead technique may reduce the effect of weld repairs on toughness.

McGaughy, T.; Boyles, L.

1990-10-31T23:59:59.000Z

185

NFRC Procedures for Applied Films  

NLE Websites -- All DOE Office Websites (Extended Search)

Applied Films Applied Films Last update: 12/10/2013 07:29 PM NFRC now has a procedure for adding applied films to substrates in Optics5 and importing those applied film constructions into WINDOW5 to be used in a whole product calculation. The information presented below is provided to help simulators with this process. Feel free to contact us at WINDOWHelp@lbl.gov with questions or comments. NFRC Applied Film Procedure Applied Film Procedures (approved by NFRC) (PDF file) Approved Applied Film List (IGDB 33.0) (PDF file) NFRC Laminate Procedure Training Powerpoint with Examples (This Powerpoint presentation was used in the NFRC web based training sessions in December 2006 and January 2007) PowerPoint Presentation (PPT file) PowerPoint Presentation (PDF file) Help and Troubleshooting

186

Best Management Practice #3: Distribution System Audits, Leak Detection, and Repair  

Energy.gov (U.S. Department of Energy (DOE))

A distribution system audit, leak detection, and repair programs help Federal facilities reduce water losses and make better use of limited water resources.

187

E-Print Network 3.0 - automobile repair shops Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Search Powered by Explorit Topic List Advanced Search Sample search results for: automobile repair shops Page: << < 1 2 3 4 5 > >> 1 Program Director: Jim Headlee Phone:...

188

E-Print Network 3.0 - anemia dna repair Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Laboratory Workshop Recent Development in DNA Repair Studies" Feb, 2009, NIRS, Chiba, Japan 2... , Matsumoto T, Niwa O. Radiation induction of delayed recombination in ......

189

Using 3D Painting to Build and Repair Parts | GE Global Research  

NLE Websites -- All DOE Office Websites (Extended Search)

a part or add material to repair an existing part. Cold spray is part of GE's expanded additive manufacturing toolkit. nteneh Kebbede, Manager of the Coating and Surface...

190

E-Print Network 3.0 - arthroscopic instability repair Sample...  

NLE Websites -- All DOE Office Websites (Extended Search)

arthroscopically... of arthroscopic rotator cuff repairs: double-row ... Source: Holzbau, Katherine R.S. - Department of Biomedical Engineering, Wake Forest University Collection:...

191

E-Print Network 3.0 - abdominal wall repair Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

fluid-structure interaction in Summary: of fluid-structure interaction in abdominal aor- tic aneurysms: initial wall stress effects 25 3... of endovascular aneurysm repair (EVAR)....

192

An integrated structural health monitoring approach to composite-based pipeline repair.  

E-Print Network (OSTI)

??One of the most common problems in the structural integrity of industrial pipelines is external corrosion. Composite materials have been accepted as a repair option… (more)

Abd Murad, Mahadi

2011-01-01T23:59:59.000Z

193

13 - Maintenance and repair of gas turbine components  

Science Journals Connector (OSTI)

Abstract: Material selection is a key factor in gas turbine performance and lifecycle cost because it has a central influence in the maintenance of the gas turbine.1 Further, the operation of a gas turbine does result in gas path degradation2 that impacts lifecycle costs and eventually design, manufacture, material choice and maintenance.3 A component repair programme that minimizes maintenance costs and maximizes equipment availability can be instituted to meet or improve lifecycle cost. This chapter presents the key factors influencing the need for maintenance and the choices available.

T. Álvarez Tejedor; R. Singh; P. Pilidis

2013-01-01T23:59:59.000Z

194

Genetics of x-ray induced double strand break repair in saccharomyces cerevisiae  

SciTech Connect

The possible fates of x-ray-induced double-strand breaks in Saccharomyces cerevisiae were examined. One possible pathway which breaks can follow, the repair pathway, was studied by assaying strains with mutations in the RAD51, RAD54, and RAD57 loci for double-strand break repair. In order of increasing radiation sensitivity one finds: rad57-1(23/sup 0/)> rad51-1(30/sup 0/)> rad54-3(36/sup 0/). At 36/sup 0/, rad54-3 cells cannot repair double-strand breaks, while 23/sup 0/, they can. Strains with the rad57-1 mutation can rejoin broken chromosomes at both temperatures. However, the low survival at 36/sup 0/ shows that the assay is not distinguishing large DNA fragments which allow cell survival from those which cause cell death. A rad51-1 strain could also rejoin broken chromosomes, and was thus capable of incomplete repair. The data can be explained with the hypothesis that rad54-3 cells are blocked in an early step of repair, while rad51-1 and rad57-1 strains are blocked in a later step of repair. The fate of double-strand breaks when they are left unrepaired was investigated with the rad54-3 mutation. If breaks are prevented from entering the RAD54 repair pathway they become uncommitted lesions. These lesions are repaired slower than the original breaks. One possible fate for an uncommitted lesion is conversion into a fixed lesion, which is likely to be an unrepairable or misrepaired double-strand break. The presence of protein synthesis after irradiation increases the probability that a break will enter the repair pathway. Evidence shows that increased probability of repair results from enhanced synthesis of repair proteins shortly after radiation. (ERB)

Budd, M.E.

1982-07-01T23:59:59.000Z

195

An integrated approach for performance enhancement in automobile repair shops  

Science Journals Connector (OSTI)

Performance management has been a topic of interest for academicians and practitioners. This paper aims at integrating fuzzy logic, data envelopment analysis (DEA) and fuzzy failure mode and effects analysis (fuzzy FMEA) for enhancing the performance in automobile (car) repair shops. A questionnaire with linguistic terms has been used to collect the data related to customer's perceived service quality and the perceptions are quantified using triangular fuzzy numbers. The weights for the service quality parameters considered are gained through analytical hierarchy process (AHP). Fuzzy perceived quality score is then calculated by combining the fuzzy numbers of criteria with the corresponding weights. Then the service performance is measured using DEA by considering both quantitative and qualitative measures. The results from DEA model provide the relative efficiency measure and efficient input/output targets for each repair shop. For further improvement of the service process, fuzzy FMEA is used to prioritise the potential failure modes. Based on the calculated fuzzy risk priority numbers (FRPN) remedial actions can be initiated.

R. Parameshwaran; P.S.S. Srinivasan; M. Punniyamoorthy

2010-01-01T23:59:59.000Z

196

Assessment of applied pipeline coating system in the U.A.E. corrosive soil condition  

SciTech Connect

Severe corrosion conditions along many section of the under ground pipeline are evident in the United Arab Emirates due to the hot humid weather and the presence of salty soil beds (Sabkha) associated with high surface water tables. These lines are usually operated at high temperatures (40-60{degrees}C) which accelerate pipe corrosion rates and incorporate potential risks to the pipe coating at Sabkha areas. ADCO experienced several pipeline external corrosion leaks within 3-7 years period of time postline commissioning. Several on-line inspections have been carried out and followed by comprehensive pipeline rehabilitation programmes with significant replacements of corroded pipe sections. Reported external corrosion was mainly due to pipeline coating failure and poor performance of applied CP system. Different cold applied coating repair systems were field tested during 1982-1983 on the main oil lines which were originally coated with hot applied coal tar enamel. The successful types of wrapping were selected for continued implementations. This paper summarises causes of pipeline coating failures and assesses the performance of applied repair coatings which have been in service for more than ten years.

Gharra, A.

1996-10-01T23:59:59.000Z

197

Effective hardware for connection and repair of polyethylene pipelines using ultrasonic modification and heat shrinkage. Part 2. Production bases for molding of epoxy repair couplings with shape memory  

Science Journals Connector (OSTI)

Production bases developed for the molding of epoxy repair couplings with shape memory are described. It is established that maximum deformation of tubular blanks of the epoxy polymers under investigation, whi...

A. E. Kolosov; O. S. Sakharov; V. I. Sivetskii…

2011-07-01T23:59:59.000Z

198

Excision of Tamoxifen-DNA Adducts by the Human Nucleotide Excision Repair System  

Science Journals Connector (OSTI)

...Using the reconstituted human excision repair system and synthetic DNA substrates, we found that the four types of tamoxifen-DNA...Using the reconstituted human excision repair system and synthetic DNA substrates, we found that the four types of tamoxifen-DNA...

Shinya Shibutani; Joyce T. Reardon; Naomi Suzuki; Aziz Sancar

2000-05-15T23:59:59.000Z

199

Bridge Damage and Repair Costs from Hurricane Katrina Jamie Padgett1  

E-Print Network (OSTI)

Bridge Damage and Repair Costs from Hurricane Katrina Jamie Padgett1 ; Reginald DesRoches2 ; Bryant to repair or replace the bridges damaged during the hurricane is estimated at over $1 billion. This paper describes the observed damage patterns to bridges, including damage attributed to storm surge, wind, impact

Padgett, Jamie Ellen

200

Models for Mixed Irradiation with a 'Reciprocal-Time' Pattern of the Repair Function  

Science Journals Connector (OSTI)

......pattern of the repair function (R; Eq. (10)) assuming the...pattern of repair function (R) using the LQ model parameters...P. D., DeLuca, P. M. Jr., Peason, D. W. and Gould...Radiat Res 95: 4556. 3. McNally, N. J., Ronde, J. De......

Shozo Suzuki; Yuri Miura; Shoichi Mizuno; Yoshiya Furusawa

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Optimizing Repair Programs for Consistent Query Answering Monica Caniupan and Leopoldo Bertossi  

E-Print Network (OSTI)

, a logic programming system that implements the stable models semantics, in particular. We also analyze be restored minimally by inserting Q(a) or elim- inating S(a). The repair program contains the following 1Optimizing Repair Programs for Consistent Query Answering Monica Caniupan and Leopoldo Bertossi

Bertossi, Leopoldo

202

Lazy Means Smart: Reducing Repair Bandwidth Costs in Erasure-coded Distributed Storage  

E-Print Network (OSTI)

- ditional bandwidth savings. 1. INTRODUCTION Erasure coding schemes, e.g. Reed-Solomon (RS) codes on the example of Reed-Solomon codes, and then explain the repair bandwidth problem. In an RS(n,k) stor- age scheme. 4. EVALUATION METHODOLOGY Evaluating the efficacy of lazy recovery in reducing repair bandwidth

Alvisi, Lorenzo

203

Myelin repair: the role of stem and precursor cells in multiple sclerosis  

Science Journals Connector (OSTI)

...repair compiled by Siddharthan Chandran, Maeve Caldwell and Nick Allen Myelin repair: the role of stem and precursor cells in...cells and the foetal and adult CNS (figure 3). There are merits and disadvantages associated with selecting any human-derived...

2008-01-01T23:59:59.000Z

204

Identification and Dissection of a Complex DNA Repair Sensitivity Phenotype in Baker's Yeast  

E-Print Network (OSTI)

Identification and Dissection of a Complex DNA Repair Sensitivity Phenotype in Baker's Yeast Ann-assisted bulk segregant analysis, we identified one other locus, MKT1, and a QTL on Chromosome VII that also) Identification and Dissection of a Complex DNA Repair Sensitivity Phenotype in Baker's Yeast. PLoS Genet 4(7): e

Kruglyak, Leonid

205

A Centralized, TreeBased Approach to Network Repair Service for Multicast Streaming Media  

E-Print Network (OSTI)

transmission, and can forward (via unicast) packets to other repair servers that did not receive the packets via the original transmission. After a fixed delay on the order of several seconds, a repair server with a transmission that is delayed by a few seconds relative to the original multicast session. However, this delayed

Maxemchuk, Nicholas F.

206

Genetic Variation in the Nucleotide Excision Repair Pathway and Colorectal Cancer Risk  

Science Journals Connector (OSTI)

...complex formation and stimulation of XPC repair activity. Mol Cell Biol 1997;17:6924-31. 35 van der Spek PJ, Eker A, Rademakers S, et al. XPC and human homologs of RAD23: intracellular localization and relationship to other nucleotide excision repair...

Sonja I. Berndt; Elizabeth A. Platz; M. Daniele Fallin; Lucy W. Thuita; Sandra C. Hoffman; Kathy J. Helzlsouer

2006-11-01T23:59:59.000Z

207

Repair welding influence on offshore pipelines residual stress fields: An experimental study  

Science Journals Connector (OSTI)

Abstract Repair welds, are frequently used in steel structures either to remedy initial fabrication defects, or to rectify in-service degradations of the components. Some previous investigations indicated that repair welding is likely to pose adverse effects on the long-term integrity of the structure exposed to high pressure and temperature actions. It is believed that high residual stresses, associated with the repair process, most probably play an important role in many of subsequent failures. Repair welds might aggravate the size, magnitude and distribution of the tensile residual stresses in the weldments. These adversely affect the component structural integrity and remaining life. So far, no generally accepted guideline is available to provide reliable evaluations on the possible side effects from the repair welding in offshore oil/gas pipelines. This paper reports the result of residual stress measurement on single/double and partial/full repair welds in offshore pipelines. The semi destructive blind hole drilling and destructive sectioning methods have been employed to measure the residual stress fields in each case. In general, the results of the two measurement methods are in reasonable agreement. Residual stresses which are caused by full and partial repairs in the studied samples slightly increased the residual stress distribution when compared to the as-welded condition. Repetition of repair welding in same area influenced the residual stresses' magnitude and distribution especially in areas close to the weld centre line.

M. Zeinoddini; S. Arnavaz; A.P. Zandi; Y. Alizadeh Vaghasloo

2013-01-01T23:59:59.000Z

208

Pipeline repair development in support of the Oman to India gas pipeline  

SciTech Connect

This paper provides a summary of development which has been conducted to date for the ultra deep, diverless pipeline repair system for the proposed Oman to India Gas Pipeline. The work has addressed critical development areas involving testing and/or prototype development of tools and procedures required to perform a diverless pipeline repair in water depths of up to 3,525 m.

Abadie, W.; Carlson, W.

1995-12-01T23:59:59.000Z

209

Rec2 Interplay with both Brh2 and Rad51 Balances Recombinational Repair in Ustilago maydis  

Science Journals Connector (OSTI)

...recombinational repair system powered by Rad51...recombinational repair system. Here, we have...in the vertebrate system, all five Rad51...catalytic muscle to power recombination...sensitivity and restoration of Rad51 focus formation...King (ed.), Handbook of genetics, vol...

Milorad Kojic; Qingwen Zhou; Michael Lisby; William K. Holloman

2006-01-15T23:59:59.000Z

210

Journal of Applied Ecology 2004  

E-Print Network (OSTI)

Journal of Applied Ecology 2004 41, 922­933 © 2004 British Ecological Society Blackwell Publishing that might guide management decisions. We tested whether ideas from landscape ecology (local vs. landscape-scale, Sacramento River, succession, vegetation Journal of Applied Ecology (2004) 41, 922­933 Introduction More than

Holl, Karen

211

Repair of gamma-ray-induced DNA base damage in xeroderma pigmentosum cells  

SciTech Connect

The repair of DNA damage produced by /sup 137/Cs gamma irradiation was measured with a preparation from Micrococcus luteus containing DNA damage-specific endonucleases in combination with alkaline elution. The frequency of these endonuclease sensitive sites (ESS) was determined after 54 or 110 Gy of oxic irradiation in normal and xeroderma pigmentosum (XP) fibroblasts from complementation groups A, C, D, and G. Repair was rapid in all cell strains with greater than 50% repair after 1.5 h of repair incubation. At later repair times, 12-17 h, more ESS remained in XP than in normal cells. The frequency of excess ESS in XP cells was approximately 0.04 per 10(9) Da of DNA per Gy which was equivalent to 10% of the initial ESS produced. The removal of ESS was comparable in XP cells with normal radiosensitivity and XP3BR cells which have been reported to be moderately radiosensitive.

Fornace, A.J. Jr.; Dobson, P.P.; Kinsella, T.J.

1986-04-01T23:59:59.000Z

212

Influence of multiple sleeve repairs on the structural integrity of gas pipelines  

Science Journals Connector (OSTI)

This paper addresses the structural integrity of gas pipelines with multiple full-encirclement weld repairs. The scope of the work is to identify and quantify the effects of the number and type of repairs, the distance between them, and the pressurization of the pipe to sleeve gap on the mechanical behaviour of the component. The study includes full-scale experimental testing and finite element modelling. Burst tests were carried out in tracts of pipelines removed from service, including various geometric configurations with and without circumferential girth welds. It is concluded that the reliability of the repairs is strongly influenced by the construction procedures and that interaction effects between successive repairs are not appreciable if the repairs are more than a half pipe diameter apart.

J.L Otegui; A Cisilino; A.E Rivas; M Chapetti; G Soula

2002-01-01T23:59:59.000Z

213

Conserved structural chemistry for incision activity in structurally non-homologous apurinic/apyrimidinic endonuclease APE1 and endonuclease IV DNA repair enzymes.  

E-Print Network (OSTI)

specificity for DNA repair enzyme superfamily. Nat StructIV. Characterization of an enzyme that recognizes oxidativemultifunctional DNA-repair enzyme exonuclease III. Nature

Tsutakawa, Susan E.

2014-01-01T23:59:59.000Z

214

Review of In-Service Inspection and Repair Technique Developments for French Liquid Metal Fast Reactors  

SciTech Connect

In-service monitoring of nuclear plants is indispensable for both the Operator and the Regulator. The notion of in-service monitoring ranges from the continuous monitoring of the reactor in operation to the thorough in-service reactor inspection during programmed shutdowns. However, the highly specific environment found in French liquid metal fast reactor plants - Phenix and Superphenix - makes monitoring and inspection complicated because of the use of a sodium coolant that is hot, opaque, and difficult to drain.The Commissariat a l'Energie Atomique, in collaboration with its traditional French partners, Electricite de France utilities and FRAMATOME/Novatome Engineering, decided to conduct a 6-yr research and development program (1994-2000) to explore this problem vis-a-vis Superphenix, as well as the possibilities of intervening within the reactor block or on components in a sodium environment. Furthermore, the safety reevaluation of Phenix, conducted between 1994 and 2003, represented an excellent 'test bench' during which the limits of inspection processes - applied to an integrated reactor concept - were surpassed using techniques such as fuel subassembly head scanning, ultrasonic examination of the core support, and visual inspection of the cover-gas plenum following a partial sodium draining. Repair techniques were investigated for cleaning of sodium wet structure surfaces, cutting of damaged parts, and welding in sodium aerosol atmosphere. Both conventional and laser processes were tested.

Baque, F. [Commissariat a l'Energie Atomique Cadarache (France)

2005-04-15T23:59:59.000Z

215

Repair Capacity for UV Light–Induced DNA Damage Associated with Risk of Nonmelanoma Skin Cancer and Tumor Progression  

Science Journals Connector (OSTI)

...reactivation|DNA repair capacity|epidemiology|skin...increasing levels of solar UV radiation (2-4...studying the DNA repair capacity (DRC) as a marker for...keratosis with cumulative solar ultraviolet exposure...influence the DNA repair capacity of normal and skin cancer-affected...

Li-E Wang; Chunying Li; Sara S. Strom; Leonard H. Goldberg; Abenaa Brewster; Zhaozheng Guo; Yawei Qiao; Gary L. Clayman; J. Jack Lee; Adel K. El-Naggar; Victor G. Prieto; Madeleine Duvic; Scott M. Lippman; Randal S. Weber; Margaret L. Kripke; and Qingyi Wei

2007-11-01T23:59:59.000Z

216

Effects of Chronic Low-Dose Ultraviolet B Radiation on DNA Damage and Repair in Mouse Skin  

Science Journals Connector (OSTI)

...of mammalian skin to solar UVB. We analyzed DNA...significantly less repair capacity than rapidly dividing...the loss of this repair capacity could partially contribute...in excision-repair capacity, and potentiation of...low-dose exposure to solar UVB may result in a significant...

David L. Mitchell; Rüdiger Greinert; Frank R. de Gruijl; Kees L. H. Guikers; Eckhard W. Breitbart; Michelle Byrom; Michelle M. Gallmeier; Megan G. Lowery; and Beate Volkmer

1999-06-15T23:59:59.000Z

217

Natural insertions in rice commonly form tandem duplications indicative of patch-mediated double-strand break induction and repair  

Science Journals Connector (OSTI)

...high-throughput sequencing of DSB repair events in humans...conventional models of DSB repair are strained to predict...proposing that long patch base excision repair (BER) on complementary...in their short-read pipeline were true positives...

Justin N. Vaughn; Jeffrey L. Bennetzen

2014-01-01T23:59:59.000Z

218

Human Polynucleotide Kinase Participates in Repair of DNA Double-Strand Breaks by Nonhomologous End Joining but not Homologous Recombination  

Science Journals Connector (OSTI)

...for the repair of topoisomerase I-mediated DNA lesions. DNA Repair (Amst) 2003;2:1087-100. 42 El-Khamisy SF, Saifi GM, Weinfeld M, et al. Defective DNA single-strand break repair in spinocerebellar ataxia with axonal neuropathy-1...

Feridoun Karimi-Busheri; Aghdass Rasouli-Nia; Joan Allalunis-Turner; Michael Weinfeld

2007-07-15T23:59:59.000Z

219

Categorical Exclusion Determinations: B3.6 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

20, 2012 20, 2012 CX-009354: Categorical Exclusion Determination High Resolution 3D Laser Imaging for Inspection, Maintenance, Repair and Operations - Phase II CX(s) Applied: A9, A11, B3.6 Date: 09/20/2012 Location(s): Colorado Offices(s): National Energy Technology Laboratory September 19, 2012 CX-009363: Categorical Exclusion Determination Development and Test of a 1,000 Level 3C Fiber Optic Borehole Seismic Receiver Array Applied to Carbon Sequestration CX(s) Applied: A1, A9, A11, B3.6 Date: 09/19/2012 Location(s): Multiple Offices(s): National Energy Technology Laboratory September 19, 2012 CX-009362: Categorical Exclusion Determination Small Scale Coal-Biomass to Liquids Using Highly Selective FT Synthesis CX(s) Applied: B3.6 Date: 09/19/2012 Location(s): Alabama Offices(s): National Energy Technology Laboratory

220

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81 - 8690 of 29,416 results. 81 - 8690 of 29,416 results. Download CX-001368: Categorical Exclusion Determination Repair Domestic Water Leak North of 719-18A CX(s) Applied: B1.3 Date: 03/16/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-001368-categorical-exclusion-determination Download CX-001369: Categorical Exclusion Determination Repair Firewater Line in B-Area East Side (Road C-2) near Post Indicator Valve 2118 CX(s) Applied: B1.3 Date: 03/16/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-001369-categorical-exclusion-determination Download CX-001370: Categorical Exclusion Determination Repair Water Leak at 607-59G at Central Sanitary Wastewater Plant

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Method of tissue repair using a composite material  

DOE Patents (OSTI)

A composite biocompatible hydrogel material includes a porous polymer matrix, the polymer matrix including a plurality of pores and providing a Young's modulus of at least 10 GPa. A calcium comprising salt is disposed in at least some of the pores. The porous polymer matrix can comprise cellulose, including bacterial cellulose. The composite can be used as a bone graft material. A method of tissue repair within the body of animals includes the steps of providing a composite biocompatible hydrogel material including a porous polymer matrix, the polymer matrix including a plurality of pores and providing a Young's modulus of at least 10 GPa, and inserting the hydrogel material into cartilage or bone tissue of an animal, wherein the hydrogel material supports cell colonization in vitro for autologous cell seeding.

Hutchens, Stacy A; Woodward, Jonathan; Evans, Barbara R; O'Neill, Hugh M

2014-03-18T23:59:59.000Z

222

Experience in the repair of steam generator auxiliary feedwater nozzle  

SciTech Connect

The auxiliary feedwater nozzle is quite often subjected to more thermal stress cycles and other loading mechanisms during their service life than the material was designed and fabricated for at the nozzle of the earlier steam generators in many nuclear plants. During plant operation, the auxiliary feedwater nozzle outlet is exposed to the hot steam from the generator side, while the auxiliary feedwater piping which contains subcooled water from the inlet often induces water hammer as a result of the steam-water mixing phenomena. The thermal cycles and the steam bubble collapse at the nozzle may cause cracking in the nozzle liner and interior surface of the nozzle, and subsequently results in structural damage to the steam generator. This presentation is intended to share the lessons learned from the evaluation of the nozzle condition and the subsequent modification and repair made to the auxiliary feedwater nozzle at the Palisades Nuclear Plant. Other nuclear plant owners may benefit from this experience.

Chao, K.K.N. [Consumers Power Co., Jackson, MI (United States)

1996-12-01T23:59:59.000Z

223

Applied Sedimentology | Open Energy Information  

Open Energy Info (EERE)

Sedimentology Jump to: navigation, search OpenEI Reference LibraryAdd to library Book: Applied Sedimentology Author R.C. Salley Published Academic Press, 2000 DOI Not Provided...

224

temperature heat pumps applied to  

E-Print Network (OSTI)

Very high- temperature heat pumps applied to energy efficiency in industry Application June 21th 2012 Energy efficiency : A contribution to environmental protection Kyoto Copenhage Emission, plastics Partnership : EDF R&D Bil

Oak Ridge National Laboratory

225

IIT SCHOOL OF APPLIED TECHNOLOGY  

E-Print Network (OSTI)

INDUSTRIAL TECHNOLOGY AND MANAGEMENT IIT SCHOOL OF APPLIED TECHNOLOGY PREPARING SKILLED INDIVIDUALS, INDUSTRIAL FACILITIES, SUPPLY CHAIN MANAGEMENT, SUSTAINABILITY AND MANUFACTURING TECHNOLOGY. #12;BE ONE to assess, implement, and utilize current technologies, and to learn how to manage industrial operations

Heller, Barbara

226

Solvent-mediated repair and patterning of surfaces by AFM  

SciTech Connect

A tip-based approach to shaping surfaces of soluble materials with nanometer-scale control is reported. The proposed method can be used, for example, to eliminate defects and inhomogeneities in surface shape, repair mechanical or laser-induced damage to surfaces, or perform 3D lithography on the length scale of an AFM tip. The phenomenon that enables smoothing and repair of surfaces is based on the transport of material from regions of high- to low-curvature within the solution meniscus formed in a solvent-containing atmosphere between the surface in question and an AFM tip scanned over the surface. Using in situ AFM measurements of the kinetics of surface remodeling on KDP (KH{sub 2}PO{sub 4}) crystals in humid air, we show that redistribution of solute material during relaxation of grooves and mounds is driven by a reduction in surface free energy as described by the Gibbs-Thomson law. We find that the perturbation from a flat interface evolves according to the diffusion equation where the effective diffusivity is determined by the product of the surface stiffness and the step kinetic coefficient. We also show that, surprisingly, if the tip is instead scanned over or kept stationary above an atomically flat area of the surface, a convex structure is formed with a diameter that is controlled by the dimensions of the meniscus, indicating that the presence of the tip and meniscus reduces the substrate chemical potential beneath that of the free surface. This allows one to create nanometer-scale 3D structures of arbitrary shape without the removal of substrate material or the use of extrinsic masks or chemical compounds. Potential applications of these tip-based phenomena are discussed.

Elhadj, S; Chernov, A; De Yoreo, J

2007-10-30T23:59:59.000Z

227

Fracture behavior of surface cracked wide plates of high strength steel containing overmatched repair welds  

SciTech Connect

This paper presents the experimental results of tests conducted using surface cracked wide plates containing overmatched repair weld joints. The deformation and fracture characteristics of the repair welded wideplates notched at the original weld deposit, repair weld and HAZ regions are discussed. The aim of this work was to investigate the effects of strength mis-match and notch position on the fracture performance of such complex weldments. Furthermore, the predictions of crack driving force using the Engineering Treatment Model for mis-matched welds (ETM-MM) procedure was compared with the results of the wide plates containing semielliptical surface cracks. For this study, 1/2K weld joints were prepared on 30 nm thick pipeline steel X65 plates by using a SAW process, resulting in 50% overmatching. Repair was performed at the cap side of the original joint up to half depth of plate thickness with a GMA welding process under hyperbaric conditions, leading to 41% yield strength overmatching. In order to assess the fracture behavior of these welds, surface cracked (semielliptic defects) wide plates containing original and repair welds were tested in tension at {minus}10 C. The surface cracked wide plate tests results have confirmed that overmatched repair weld metal can exert a significant effect on the deformation and fracture behavior of the wide plates. Wide plates containing root cracks clearly showed a shielding effect of the overmatched repair weld since it prevented development of through thickness ligament yielding.

Junghans, E.; Kocak, M.; Schwalbe, K.H. [GKSS Research Center, Geesthacht (Germany). Inst. of Materials Research

1996-12-01T23:59:59.000Z

228

Effect of multiple repairs in girth welds of pipelines on the mechanical properties  

SciTech Connect

This work presents the results of multiple weld repairs in the same area in seamless API X-52 microalloyed steel pipe. Four conditions of shielded metal arc welding repairs and one as-welded specimen of the girth weld were characterized to determine changes in the microstructure, grain size in the heat affected zone, and to evaluate their effect on the mechanical properties of the weld joints. The mechanical properties by means of tension tests, Charpy-V impact resistance and Vickers hardness of the welds were analyzed. The results indicate that significant changes are not generated in the microstructural constituents of the heat affected zone. Grain growth in the heat affected zone at the specimen mid-thickness with the number of repairs was observed. Tensile strength of the weld joints meets the requirement of the API 1104 standard even after the fourth weld repair. Significant reduction in Charpy-V impact resistance with the number of weld repairs was found when the notch location was in the intersection of the fusion line with the specimen mid-thickness. A significant increase in the Vickers hardness of the heat affected zone occurred after the first repair and a gradual decrease in the Vickers hardness occurred as the number of repairs increases.

Vega, O.E.; Hallen, J.M. [Departamento de Ingenieria Metalurgica, ESIQIE-IPN, Laboratorios Pesados de Metalurgia, UPALM, Zacatenco, C.P. 07738, Mexico D.F. (Mexico); Villagomez, A. [Construcciones Maritimas Mexicanas, CMM-PROTEXA, Av. Periferica s/n, Fracc. Lomas de Holche, C.P. 24120, Cd. del Carmen, Campeche (Mexico); Contreras, A. [Instituto Mexicano del Petroleo, Investigacion en Ductos, Corrosion y Materiales, Eje Central Lazaro Cardenas Norte 152 Col. San Bartolo Atepehuacan, C.P. 07730, Mexico D.F. (Mexico)], E-mail: acontrer@imp.mx

2008-10-15T23:59:59.000Z

229

Fabrication Flaw Density and Distribution In Repairs to Reactor Pressure Vessel and Piping Welds  

SciTech Connect

The Pacific Northwest National Laboratory is developing a generalized fabrication flaw distribution for the population of nuclear reactor pressure vessels and for piping welds in U.S. operating reactors. The purpose of the generalized flaw distribution is to predict component-specific flaw densities. The estimates of fabrication flaws are intended for use in fracture mechanics structural integrity assessments. Structural integrity assessments, such as estimating the frequency of loss-of-coolant accidents, are performed by computer codes that require, as input, accurate estimates of flaw densities. Welds from four different reactor pressure vessels and a collection of archived pipes have been studied to develop empirical estimates of fabrication flaw densities. This report describes the fabrication flaw distribution and characterization in the repair weld metal of vessels and piping. This work indicates that large flaws occur in these repairs. These results show that repair flaws are complex in composition and sometimes include cracks on the ends of the repair cavities. Parametric analysis using an exponential fit is performed on the data. The relevance of construction records is established for describing fabrication processes and product forms. An analysis of these records shows there was a significant change in repair frequency over the years when these components were fabricated. A description of repair flaw morphology is provided with a discussion of fracture mechanics significance. Fabrication flaws in repairs are characterized using optimized-access, high-sensitivity nondestructive ultrasonic testing. Flaw characterizations are then validated by other nondestructive evaluation techniques and complemented by destructive testing.

GJ Schuster, FA Simonen, SR Doctor

2008-04-01T23:59:59.000Z

230

Comparative Study of Inguinal Hernia Repair Rates After Radical Prostatectomy or External Beam Radiotherapy  

SciTech Connect

Purpose: We tested the hypothesis that patients treated for localized prostate cancer with radical prostatectomy (RP) have a higher risk of requiring an inguinal hernia (IH) repair than their counterparts treated with external beam radiotherapy (EBRT). Methods and Materials: Within the Quebec Health Plan database, we identified 6,422 men treated with RP and 4,685 men treated with EBRT for localized prostate cancer between 1990 and 2000, in addition to 6,933 control patients who underwent a prostate biopsy. From among that population, we identified patients who underwent a unilateral or bilateral hernia repair after either RP or EBRT. Kaplan-Meier plots showed IH repair-free survival rates. Univariable and multivariable Cox regression models tested the predictors of IH repair after RP or EBRT. Covariates consisted of age, year of surgery, and Charlson Comorbidity Index. Results: IH repair-free survival rates at 1, 2, 5, and 10 years were 96.8, 94.3, 90.5, and 86.2% vs. 98.9, 98.0, 95.4, and 92.2%, respectively, in RP vs. EBRT patients (log-rank test, p < 0.001). IH repair-free survival rates in the biopsy population were 98.3, 97.1, 94.9, and 90.2% at the same four time points. In multivariable Cox regression models, RP predisposed to a 2.3-fold higher risk of IH repair than EBRT (p < 0.001). Besides therapy type, patient age (p < 0.001) represented the only other independent predictor of IH repair. Conclusions: RP predisposes to a higher rate of IH repair relative to EBRT. This observation should be considered at informed consent.

Lughezzani, Giovanni [Cancer Prognostics and Health Outcomes Unit, University of Montreal Health Center, Montreal, Quebec (Canada); Department of Urology, Vita-Salute San Raffaele University, Milan (Italy); Sun, Maxine [Cancer Prognostics and Health Outcomes Unit, University of Montreal Health Center, Montreal, Quebec (Canada); Perrotte, Paul [Department of Urology, University of Montreal, Montreal, Quebec (Canada); Alasker, Ahmed; Jeldres, Claudio [Cancer Prognostics and Health Outcomes Unit, University of Montreal Health Center, Montreal, Quebec (Canada); Isbarn, Hendrik; Budaeus, Lars [Cancer Prognostics and Health Outcomes Unit, University of Montreal Health Center, Montreal, Quebec (Canada); Martini-clinic, Prostate Cancer Center Hamburg-Eppendorf, Hamburg (Germany); Lattouf, Jean-Baptiste; Valiquette, Luc; Benard, Francois; Saad, Fred [Department of Urology, University of Montreal, Montreal, Quebec (Canada); Graefen, Markus [Cancer Prognostics and Health Outcomes Unit, University of Montreal Health Center, Montreal, Quebec (Canada); Martini-clinic, Prostate Cancer Center Hamburg-Eppendorf, Hamburg (Germany); Montorsi, Francesco [Department of Urology, Vita-Salute San Raffaele University, Milan (Italy); Karakiewicz, Pierre I., E-mail: pierre.karakiewicz@umontreal.c [Cancer Prognostics and Health Outcomes Unit, University of Montreal Health Center, Montreal, Quebec (Canada)

2010-12-01T23:59:59.000Z

231

Maintenance and repair expenditures: determinants and tradeoffs with new capital goods  

Science Journals Connector (OSTI)

Traditionally economic analysis has focused on new capital investment, while ignoring expenditures to maintain or repair existing stock. Recent, broader theories of replacement have emphasized the important role played by both maintenance and utilization rates. However, the decision to extend the service life of capital has been given scant empirical attention, owing partly to a lack of appropriate data. This study exploits survey data that report annual maintenance/repair expenditures for Canadian manufacturing industries. A standard production framework, modified to incorporate endogenous depreciation, guides the econometric analysis. The empirical results indicate that the cost of capital, among other variables, has a statistically significant effect on maintenance/repair decisions.

J.K. Mullen; Martin Williams

2004-01-01T23:59:59.000Z

232

Assessment of Concrete Repair Techniques for Radiologically Contaminated Tank Farm Pump and Valve Pits  

SciTech Connect

As part of the scope of Project W-314, ''Tank Farm Restoration and Safe Operations,'' the condition of pump and valve pit walls and floors is being assessed, and repairs made as needed, to support upgrading the infrastructure necessary to safely transfer tank waste for treatment. Flaws in the surfaces of the pits (e.g., concrete crack/faults, protective coating deterioration) must be repaired to ensure containment integrity and to facilitate future decontamination of the pits. This engineering study presents a cost/risk/benefit evaluation of concrete and protective coating repair methods in pump and valve pits using various manual and remote tool systems.

MINTEER, D.J.

2000-09-19T23:59:59.000Z

233

An alternative methodology to repair localized corrosion damage in metallic pipelines with epoxy resins  

Science Journals Connector (OSTI)

The present work is concerned with the analysis of epoxy repair systems for metallic pipelines undergoing elastic or inelastic deformations with localized corrosion damage that impair the serviceability. In the case of trough-thickness damage, the main focus is to assure an adequate application of the epoxy filler in such a way the pipe wont leak after repair. Such a procedure can be used or not associated with a composite sleeve that assures a satisfactory level of structural integrity. Examples concerning the use of repair systems in different damage situations are presented and analyzed showing the possibilities of practical use of the proposed methodology.

H.S. da Costa-Mattos; J.M.L. Reis; R.F. Sampaio; V.A. Perrut

2009-01-01T23:59:59.000Z

234

Microsoft Word - SPR Emergency Pipeline Repair, 2013-2017 NEPA.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emergency Pipeline and Piping Repair, 2013-2017 Emergency Pipeline and Piping Repair, 2013-2017 Description: Subcontractor shall shall provide all labor, materials, equipment, supervision, transportation and services required to perform emergency repairs on the SPR system site piping (including underground fire protection systems and offsite pipelines). Subcontractor shall mobilize equipment to perform excavation, backfill, hydrostatic testing, welding and cutting, blasting, coating and painting of large and small diameter piping systems on the SPR facilities and offsite pipelines. Subcontractor shall also assist in emergency exercises by assemblying temporary piping spools and positioning pump skids and temporary supports. This NEPA document covers the period from 2013-2017.

235

BNL | Accelerators for Applied Research  

NLE Websites -- All DOE Office Websites (Extended Search)

Accelerators for Applied Research Accelerators for Applied Research Brookhaven National Lab operates several accelerator facilities dedicated to applied research. These facilities directly address questions and concerns on a tremendous range of fields, including medical imaging, cancer therapy, computation, and space exploration. Leading scientists lend their expertise to these accelerators and offer crucial assistant to collaborating researchers, pushing the limits of science and technology. Interested in gaining access to these facilities for research? See the contact number listed for each facility. RHIC tunnel Brookhaven Linac Isotope Producer The Brookhaven Linac Isoptope Producer (BLIP)-positioned at the forefront of research into radioisotopes used in cancer treatment and diagnosis-produces commercially unavailable radioisotopes for use by the

236

FE Categorical Exclusions | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8, 2010 8, 2010 CX-004402: Categorical Exclusion Determination The Use of Scrap Tires for Oil Well Stimulation CX(s) Applied: B3.6 Date: 11/08/2010 Location(s): Monroeville, Pennsylvania Office(s): Fossil Energy, National Energy Technology Laboratory November 8, 2010 CX-004401: Categorical Exclusion Determination The Use of Scrap Tires for Oil Well Stimulation CX(s) Applied: B3.6 Date: 11/08/2010 Location(s): Waynesburg, Pennsylvania Office(s): Fossil Energy, National Energy Technology Laboratory November 5, 2010 CX-004400: Categorical Exclusion Determination Repair Brick Support Plates on Connecting Bridges - Building 58 CX(s) Applied: B2.3 Date: 11/05/2010 Location(s): Allegheny City, Pennsylvania Office(s): Fossil Energy, National Energy Technology Laboratory November 5, 2010

237

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

11 - 25020 of 31,917 results. 11 - 25020 of 31,917 results. Download CX-005847: Categorical Exclusion Determination Rocky Reach - Maple Valley Access Road Repair CX(s) Applied: B1.3 Date: 05/05/2011 Location(s): King County, Washington Office(s): Bonneville Power Administration http://energy.gov/nepa/downloads/cx-005847-categorical-exclusion-determination Download CX-005772: Categorical Exclusion Determination C-Area Characterization CX(s) Applied: B3.1 Date: 04/13/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-005772-categorical-exclusion-determination Download CX-005774: Categorical Exclusion Determination Decommissioning of Flow Through Filter Diesel Generators CX(s) Applied: B1.27 Date: 04/12/2011

238

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6, 2012 6, 2012 CX-009331: Categorical Exclusion Determination High Resolution 3D Laser Imaging for Inspection, Maintenance, Repair and Operations Phase II CX(s) Applied: B3.6 Date: 09/26/2012 Location(s): New Jersey Offices(s): National Energy Technology Laboratory September 26, 2012 CX-009433: Categorical Exclusion Determination Center for Biomass Utilization Renewal of Grant CX(s) Applied: B3.6 Date: 09/26/2012 Location(s): North Dakota, Minnesota Offices(s): Golden Field Office September 25, 2012 CX-009242: Categorical Exclusion Determination Development of Light Water Reactor Fuels with Enhanced Accident Tolerance - AREVA Federal Services LLC CX(s) Applied: B3.6, B3.15 Date: 09/25/2012 Location(s): Florida, Wisconsin Offices(s): Nuclear Energy September 25, 2012 CX-009241: Categorical Exclusion Determination

239

Categorical Exclusion Determinations: Colorado | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

September 5, 2012 September 5, 2012 CX-009189: Categorical Exclusion Determination (0675-1594) Eaton Corporation - Predictive Battery Management for Commercial Hybrid Vehicles CX(s) Applied: B3.6 Date: 09/05/2012 Location(s): Michigan, Minnesota, Colorado Offices(s): Advanced Research Projects Agency-Energy August 31, 2012 CX-009227: Categorical Exclusion Determination Beaver Creek- Big Sandy 115 Kilovolt Transmission Line Structure Replacements - Last Chance Fire CX(s) Applied: B4.13 Date: 08/31/2012 Location(s): Colorado Offices(s): Western Area Power Administration-Rocky Mountain Region August 29, 2012 CX-008913: Categorical Exclusion Determination High Resolution 3D Laser Imaging for Inspection, Maintenance, Repair and Operations - Phase II CX(s) Applied: A9, B3.6 Date: 08/29/2012

240

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

51 - 14260 of 29,416 results. 51 - 14260 of 29,416 results. Download CX-010135: Categorical Exclusion Determination Provide an Improved Heating, Ventilation and Air Conditioning System in 705-A CX(s) Applied: B1.3 Date: 03/11/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-010135-categorical-exclusion-determination Download CX-010136: Categorical Exclusion Determination Repair Sanitary Sewer Line South of 725-N CX(s) Applied: B1.3 Date: 03/11/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-010136-categorical-exclusion-determination Download CX-010137: Categorical Exclusion Determination Correct Obstruction in the Sprinkler System on Level 3 of HB-Line CX(s) Applied: B2.5

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5, 2010 5, 2010 CX-002268: Categorical Exclusion Determination From Sensing to Enhancing the Brain Processes CX(s) Applied: B3.12 Date: 02/25/2010 Location(s): Albuquerque, New Mexico Office(s): NNSA-Headquarters, Sandia Site Office February 24, 2010 CX-006661: Categorical Exclusion Determination Repair Flowline at 83-AX-4 CX(s) Applied: B5.2, B5.4 Date: 02/24/2010 Location(s): Casper, Wyoming Office(s): RMOTC February 24, 2010 CX-001126: Categorical Exclusion Determination 183-2C Removal of Switchgear Cubicle CX(s) Applied: B4.10 Date: 02/24/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office February 24, 2010 CX-000907: Categorical Exclusion Determination Improved Design Tools for Surface Water and Standing Column Well Heat Pump

242

Washington | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

25, 2010 25, 2010 CX-003611: Categorical Exclusion Determination Schultz - Raver Number 3 and 4 500-kilovolt (kV) Transmission Lines Spacer Replacement CX(s) Applied: B1.3 Date: 08/25/2010 Location(s): King County, Washington Office(s): Bonneville Power Administration August 25, 2010 CX-003610: Categorical Exclusion Determination Ross-Lexington Number 1 Access Road Repair Project CX(s) Applied: B1.3 Date: 08/25/2010 Location(s): Cowlitz County, Washington Office(s): Bonneville Power Administration August 25, 2010 CX-003609: Categorical Exclusion Determination Cushman North Fork Skokomish Powerhouse CX(s) Applied: A9 Date: 08/25/2010 Location(s): Tacoma, Washington Office(s): Energy Efficiency and Renewable Energy, Golden Field Office August 25, 2010 CX-003614: Categorical Exclusion Determination

243

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8, 2011 8, 2011 CX-005134: Categorical Exclusion Determination Provision of Funds to the Yakama Nation for the Purchase of Three Parcels of Property Along Reecer Creek CX(s) Applied: B1.25 Date: 01/28/2011 Location(s): Kittitas County, Washington Office(s): Bonneville Power Administration January 27, 2011 CX-005173: Categorical Exclusion Determination Roof Replacement/Repair, Gutters, and Downspouts CX(s) Applied: B5.1 Date: 01/27/2011 Location(s): Northampton County, Pennsylvania Office(s): Energy Efficiency and Renewable Energy, Golden Field Office January 27, 2011 CX-005127: Categorical Exclusion Determination Philadelphia (Pennsylvania): Energy Loan to Community Legal Services for the Erie Avenue Office CX(s) Applied: B5.1 Date: 01/27/2011 Location(s): Philadelphia, Pennsylvania

244

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

21 - 26530 of 28,560 results. 21 - 26530 of 28,560 results. Download CX-008618: Categorical Exclusion Determination Evaluation of Sorbent/Ion Exchangers for Radiochemical and Metal Separations CX(s) Applied: B3.6 Date: 06/26/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-008618-categorical-exclusion-determination Download CX-008619: Categorical Exclusion Determination Roof Repair at 105-C Disassembly CX(s) Applied: B1.3 Date: 06/22/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-008619-categorical-exclusion-determination Download CX-008620: Categorical Exclusion Determination F-Tank Farm Sump Pump and Discharge Piping CX(s) Applied: B1.3 Date: 06/22/2012 Location(s): South Carolina

245

Categorical Exclusion Determinations: National Energy Technology Laboratory  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0, 2012 0, 2012 CX-009354: Categorical Exclusion Determination High Resolution 3D Laser Imaging for Inspection, Maintenance, Repair and Operations - Phase II CX(s) Applied: A9, A11, B3.6 Date: 09/20/2012 Location(s): Colorado Offices(s): National Energy Technology Laboratory September 20, 2012 CX-009353: Categorical Exclusion Determination The Sustainability Workshop (Energy Regional Innovation Cluster) CX(s) Applied: A9 Date: 09/20/2012 Location(s): Pennsylvania Offices(s): National Energy Technology Laboratory September 20, 2012 CX-009352: Categorical Exclusion Determination Navy Yard Network Operations Center (Energy Regional Innovation Cluster) CX(s) Applied: A1, A9, B2.2 Date: 09/20/2012 Location(s): Pennsylvania Offices(s): National Energy Technology Laboratory September 19, 2012

246

Categorical Exclusion Determinations: National Energy Technology Laboratory  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5, 2010 5, 2010 CX-004434: Categorical Exclusion Determination Geothermal Incentive Program CX(s) Applied: B5.1 Date: 11/05/2010 Location(s): Stonington, Connecticut Office(s): Energy Efficiency and Renewable Energy, National Energy Technology Laboratory November 5, 2010 CX-004400: Categorical Exclusion Determination Repair Brick Support Plates on Connecting Bridges - Building 58 CX(s) Applied: B2.3 Date: 11/05/2010 Location(s): Allegheny City, Pennsylvania Office(s): Fossil Energy, National Energy Technology Laboratory November 5, 2010 CX-004399: Categorical Exclusion Determination Mississippi Energy Efficiency Appliance Rebate Program CX(s) Applied: B5.1 Date: 11/05/2010 Location(s): Mississippi Office(s): Energy Efficiency and Renewable Energy, National Energy Technology Laboratory

247

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81 - 6690 of 28,905 results. 81 - 6690 of 28,905 results. Download CX-005760: Categorical Exclusion Determination F-10 Outfall Stairs/Landing Installation CX(s) Applied: B1.3 Date: 05/04/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-005760-categorical-exclusion-determination Download CX-005761: Categorical Exclusion Determination 707-C Storm Drain Repairs CX(s) Applied: B1.3 Date: 05/04/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-005761-categorical-exclusion-determination Download CX-005762: Categorical Exclusion Determination Replacement of Critical Fire Hydrants in A-Area CX(s) Applied: B1.3

248

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

01 - 4710 of 26,777 results. 01 - 4710 of 26,777 results. Download CX-005797: Categorical Exclusion Determination Replace Poles 356 and 425 in Forestry (G-Area) CX(s) Applied: B1.3 Date: 04/06/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-005797-categorical-exclusion-determination Download CX-005798: Categorical Exclusion Determination Replace Pole 25 Due to Wood Pecker Holes CX(s) Applied: B1.3 Date: 04/06/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-005798-categorical-exclusion-determination Download CX-005799: Categorical Exclusion Determination Repair of Fire Water Line Near 254-13F CX(s) Applied: B1.3

249

Categorical Exclusion Determinations: B1.3 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

July 31, 2013 July 31, 2013 CX-010843: Categorical Exclusion Determination Subcontractor Repair of Roof Leak in Rm. F45 at 703-1B CX(s) Applied: B1.3 Date: 07/31/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office July 31, 2013 CX-010732: Categorical Exclusion Determination 2013 Spokane District Wood pole Replacement Projects CX(s) Applied: B1.3 Date: 07/31/2013 Location(s): Washington, Washington, Washington, Washington, Idaho Offices(s): Bonneville Power Administration July 31, 2013 CX-010840: Categorical Exclusion Determination Place Old A-Cell Block Crane in Sealand Container for Disposal CX(s) Applied: B1.3 Date: 07/31/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office July 31, 2013 CX-010884: Categorical Exclusion Determination

250

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

July 31, 2013 July 31, 2013 CX-010844: Categorical Exclusion Determination Subcontractor Repair of Leak Over Entry Door #1 at 703-B CX(s) Applied: B1.3 Date: 07/31/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office July 30, 2013 CX-010846: Categorical Exclusion Determination Install Stud, Shims, and Nut in the L-Basin 70-Ton Cask Lid Support Structure CX(s) Applied: B2.5 Date: 07/30/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office July 23, 2013 CX-010850: Categorical Exclusion Determination Install Well Pump into the F-Tank Farm Catch Tank FL-241901-WTS-TK-1 CX(s) Applied: B1.3 Date: 07/23/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office July 23, 2013 CX-010849: Categorical Exclusion Determination

251

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

41 - 27450 of 28,904 results. 41 - 27450 of 28,904 results. Download CX-008619: Categorical Exclusion Determination Roof Repair at 105-C Disassembly CX(s) Applied: B1.3 Date: 06/22/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-008619-categorical-exclusion-determination Download CX-008620: Categorical Exclusion Determination F-Tank Farm Sump Pump and Discharge Piping CX(s) Applied: B1.3 Date: 06/22/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-008620-categorical-exclusion-determination Download CX-008621: Categorical Exclusion Determination Replace 766-H Deteriorated Grease Trap CX(s) Applied: B1.3 Date: 06/21/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office

252

Categorical Exclusion Determinations: B1.3 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

February 22, 2011 February 22, 2011 CX-005372: Categorical Exclusion Determination Repair Bayou Choctaw Timber Pipe Supports CX(s) Applied: B1.3 Date: 02/22/2011 Location(s): Bayou Choctaw, Louisiana Office(s): Strategic Petroleum Reserve Field Office February 22, 2011 CX-005371: Categorical Exclusion Determination West Hackberry Off-Site Services Contract, 2011-2013 CX(s) Applied: B1.3 Date: 02/22/2011 Location(s): West Hackberry, Texas Office(s): Strategic Petroleum Reserve Field Office February 22, 2011 CX-005370: Categorical Exclusion Determination Clean and Inspect West Hackberry (WHT-14) Brine Tank CX(s) Applied: B1.3 Date: 02/22/2011 Location(s): West Hackberry, Louisiana Office(s): Strategic Petroleum Reserve Field Office February 22, 2011 CX-005369: Categorical Exclusion Determination

253

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

December 5, 2011 December 5, 2011 CX-007511: Categorical Exclusion Determination Record of Categorical Exclusion for Repair Erosion Problems at Big Hill Raw Water Intake Structure CX(s) Applied: B1.3 Date: 12/05/2011 Location(s): Texas Offices(s): Strategic Petroleum Reserve Field Office December 5, 2011 CX-007789: Categorical Exclusion Determination Associated Electric Cooperative, Inc. Substation Improvements CX(s) Applied: B4.6 Date: 12/05/2011 Location(s): Missouri Offices(s): Southwestern Power Administration December 5, 2011 CX-007390: Categorical Exclusion Determination Hot Carrier Collection in Thin Film Silicon with Tailored Nanocrystalline/Amorphous Structure CX(s) Applied: B3.15, A9, B3.6 Date: 12/05/2011 Location(s): Colorado Offices(s): Golden Field Office December 5, 2011

254

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2, 2009 2, 2009 CX-000393: Categorical Exclusion Determination Carbon Capture and Sequestration (by Enhanced Oil Recovery) Project Phase 1 CX(s) Applied: A1, A9, B3.1 Date: 11/12/2009 Location(s): Austin, Texas Office(s): Fossil Energy, National Energy Technology Laboratory November 12, 2009 CX-004894: Categorical Exclusion Determination Peacock Substation Washed Out Area Repair CX(s) Applied: B1.3 Date: 11/12/2009 Location(s): Mohave County, Arizona Office(s): Western Area Power Administration-Desert Southwest Region November 12, 2009 CX-000394: Categorical Exclusion Determination Carbon Capture and Sequestration (by Enhance Oil Recovery) Project Phase 1 CX(s) Applied: A1, A9, B3.1 Date: 11/12/2009 Location(s): Texas City, Texas Office(s): Fossil Energy, National Energy Technology Laboratory

255

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

41 - 25650 of 31,917 results. 41 - 25650 of 31,917 results. Download CX-005760: Categorical Exclusion Determination F-10 Outfall Stairs/Landing Installation CX(s) Applied: B1.3 Date: 05/04/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-005760-categorical-exclusion-determination Download CX-005761: Categorical Exclusion Determination 707-C Storm Drain Repairs CX(s) Applied: B1.3 Date: 05/04/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-005761-categorical-exclusion-determination Download CX-005762: Categorical Exclusion Determination Replacement of Critical Fire Hydrants in A-Area CX(s) Applied: B1.3

256

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savannah River Operations Savannah River Operations Office Categorical Exclusion Determinations: Savannah River Operations Office Categorical Exclusion Determinations issued by Savannah River Operations Office. DOCUMENTS AVAILABLE FOR DOWNLOAD September 10, 2013 CX-010669: Categorical Exclusion Determination 484-17D Coal Yard Remediation CX(s) Applied: B6.1 Date: 06/07/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 1, 2013 CX-010837: Categorical Exclusion Determination Disassembly, Relocation, and Reassembly of a Metal-framed Quonset Hut CX(s) Applied: B1.22 Date: 08/01/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 1, 2013 CX-010836: Categorical Exclusion Determination Subcontractor Roof Repair at 717-12S CX(s) Applied: B1.3

257

Categorical Exclusion Determinations: Arkansas | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Arkansas Arkansas Categorical Exclusion Determinations: Arkansas Location Categorical Exclusion Determinations issued for actions in Arkansas. DOCUMENTS AVAILABLE FOR DOWNLOAD September 16, 2010 CX-003909: Categorical Exclusion Determination Emergency Levee, Bank, and Drainage Repairs CX(s) Applied: B2.5 Date: 09/16/2010 Location(s): Craighead County, Arkansas Office(s): Southwestern Power Administration September 13, 2010 CX-003762: Categorical Exclusion Determination Arkansas-County-Pulaski CX(s) Applied: B1.32, B2.5, B5.1 Date: 09/13/2010 Location(s): Pulaski County, Arkansas Office(s): Energy Efficiency and Renewable Energy September 8, 2010 CX-003788: Categorical Exclusion Determination Arkansas Appliance Rebate Program CX(s) Applied: A9, B5.1 Date: 09/08/2010 Location(s): Arkansas

258

FE Categorical Exclusions | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

February 12, 2010 February 12, 2010 CX-002614: Categorical Exclusion Determination Research and Education of Carbon Dioxide Separation from Coal Combustion Flue Gases with Regenerable Magnesium Solutions CX(s) Applied: B3.1, A9 Date: 02/12/2010 Location(s): Cincinnati, Ohio Office(s): Fossil Energy, National Energy Technology Laboratory February 12, 2010 CX-000779: Categorical Exclusion Determination Hardgrove Grindability Index (HGI) Building 83 CX(s) Applied: B3.6 Date: 02/12/2010 Location(s): Pittsburgh, Pennsylvania Office(s): Fossil Energy, National Energy Technology Laboratory February 11, 2010 CX-000873: Categorical Exclusion Determination Clean, Inspect, and Repair BMT-27 CX(s) Applied: B1.3 Date: 02/11/2010 Location(s): Texas Office(s): Fossil Energy, Strategic Petroleum Reserve Field Office

259

Categorical Exclusion Determinations: Colorado | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

May 18, 2012 May 18, 2012 CX-008766: Categorical Exclusion Determination Asphalt Repair and Concrete Work Activities at the Grand Junction, Colorado, Disposal Site CX(s) Applied: B1.3 Date: 05/18/2012 Location(s): Colorado Offices(s): Legacy Management May 15, 2012 CX-008238: Categorical Exclusion Determination Recovery Act: Colorado State Capitol Building Geothermal Program CX(s) Applied: A9, B2.1, B5.19 Date: 05/15/2012 Location(s): Colorado Offices(s): Golden Field Office May 9, 2012 CX-008401: Categorical Exclusion Determination Giant Track Communications Tower Removal CX(s) Applied: B1.19 Date: 05/09/2012 Location(s): Colorado Offices(s): Western Area Power Administration-Rocky Mountain Region May 9, 2012 CX-008381: Categorical Exclusion Determination Big Thompson to Flatiron 13.8 Kilovolt Transmission Line Structure

260

Categorical Exclusion Determinations: B1.3 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

March 4, 2010 March 4, 2010 CX-001134: Categorical Exclusion Determination Repair Water Leak in L-Area Valve 075 CX(s) Applied: B1.3 Date: 03/04/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office March 4, 2010 CX-001129: Categorical Exclusion Determination Cut and Cap Firewater Line Tap-Off Near 714-7N CX(s) Applied: B1.3 Date: 03/04/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office March 3, 2010 CX-001185: Categorical Exclusion Determination Replace Spacer Dampers Along the Wautoma-Rock Creek Number 1 500 Kilovolt Transmission Line CX(s) Applied: B1.3 Date: 03/03/2010 Location(s): Benton County, Yakima County, Office(s): Bonneville Power Administration March 2, 2010

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2, 2009 2, 2009 CX-001125: Categorical Exclusion Determination Blading of Washed Out Access Road and Repairing the Washed Out Area Inside the Substation Fence CX(s) Applied: B1.3 Date: 11/12/2009 Location(s): Mohave County, Arizona Office(s): Western Area Power Administration-Desert Southwest Region November 12, 2009 CX-000383: Categorical Exclusion Determination Cemex Commercial-Scale Carbon Dioxide Capture and Sequestration for the Cement Industry CX(s) Applied: A1, A9, B3.1 Date: 11/12/2009 Location(s): Odessa, Texas Office(s): Fossil Energy, National Energy Technology Laboratory November 12, 2009 CX-000382: Categorical Exclusion Determination Cemex Commercial-Scale Carbon Dioxide Capture and Sequestration for the Cement Industry CX(s) Applied: A1, A9, B3.6 Date: 11/12/2009

262

Categorical Exclusion Determinations: B6.1 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

23, 2010 23, 2010 CX-003924: Categorical Exclusion Determination Delineation, Identification, Characterization, and Clean Up of Suspected Waste Area CX(s) Applied: B3.1, B6.1 Date: 09/23/2010 Location(s): Pittsburgh, Pennsylvania Office(s): Fossil Energy, National Energy Technology Laboratory September 3, 2010 CX-003961: Categorical Exclusion Determination N-Area Resource Conservation and Recovery Act Closure Activities CX(s) Applied: B6.1 Date: 09/03/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office September 2, 2010 CX-003826: Categorical Exclusion Determination Project 1712 Repair OF002 Cured-in-Place Pipe Liner Near AICO Inlet CX(s) Applied: B6.1 Date: 09/02/2010 Location(s): Kansas Office(s): Kansas City Site Office, NNSA-Headquarters

263

Categorical Exclusion Determinations: B1.3 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

April 4, 2013 April 4, 2013 CX-010095: Categorical Exclusion Determination Casa Grande Substation, CAG 262 Breaker Replacement CX(s) Applied: B1.3 Date: 04/04/2013 Location(s): Arizona Offices(s): Western Area Power Administration-Desert Southwest Region April 1, 2013 CX-010106: Categorical Exclusion Determination Flaming Gorge Microwave Site Communications Building Access Road Repairs CX(s) Applied: B1.3 Date: 04/01/2013 Location(s): Utah Offices(s): Western Area Power Administration-Rocky Mountain Region March 26, 2013 CX-010105: Categorical Exclusion Determination Urban Transmission Line Danger Tree Management CX(s) Applied: B1.3 Date: 03/26/2013 Location(s): Colorado, Colorado, Colorado, Colorado, Wyoming Offices(s): Western Area Power Administration-Rocky Mountain Region

264

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

October 3, 2011 October 3, 2011 CX-006944: Categorical Exclusion Determination Remove Insulation from High Point Flush Pump Drain Valve CX(s) Applied: B1.3 Date: 10/03/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, National Energy Technology Laboratory September 29, 2011 CX-006946: Categorical Exclusion Determination Operation of Accredited Industrial Hygiene (IH) Laboratory in Building 772-F, Revision 1 CX(s) Applied: B3.6 Date: 09/29/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, National Energy Technology Laboratory September 28, 2011 CX-006955: Categorical Exclusion Determination Repair Radiological Fixative Coatings in F Tank Farm CX(s) Applied: B1.3 Date: 09/28/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Sandia Site Office

265

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7, 2012 7, 2012 CX-009327: Categorical Exclusion Determination Gas Hydrate Dynamics on the Alaskan Beaufort Continental Slope: Modeling and Field Characterization CX(s) Applied: A9 Date: 09/27/2012 Location(s): Texas Offices(s): National Energy Technology Laboratory September 26, 2012 CX-009434: Categorical Exclusion Determination Deployable Commercial Rooftop Solar Electric System CX(s) Applied: B5.15 Date: 09/26/2012 Location(s): New York Offices(s): Golden Field Office September 26, 2012 CX-009169: Categorical Exclusion Determination Virgin Islands State Energy Program CX(s) Applied: A9, A11 Date: 09/26/2012 Location(s): Virgin Islands Offices(s): Golden Field Office September 26, 2012 CX-009331: Categorical Exclusion Determination High Resolution 3D Laser Imaging for Inspection, Maintenance, Repair and

266

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1, 2013 1, 2013 CX-010818: Categorical Exclusion Determination Technology Integration Program - Field Trial - Site Three CX(s) Applied: B3.1 Date: 08/01/2013 Location(s): Texas Offices(s): National Energy Technology Laboratory August 1, 2013 CX-010833: Categorical Exclusion Determination Subcontractor Will Clean Out Gutters Causing Leaks in 706-N CX(s) Applied: B1.3 Date: 08/01/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 1, 2013 CX-010832: Categorical Exclusion Determination Subcontractor Will Perform Roof Leak Repairs on 717-8N CX(s) Applied: B1.3 Date: 08/01/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 1, 2013 CX-010817: Categorical Exclusion Determination Technology Integration Program - Field Trial - Site Three

267

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

91 - 27400 of 28,560 results. 91 - 27400 of 28,560 results. Download CX-007772: Categorical Exclusion Determination Idaho National Laboratory Asphalt Repair Project - North Wind Services, LLC CX(s) Applied: B1.3 Date: 11/28/2011 Location(s): Idaho Offices(s): Nuclear Energy, Idaho Operations Office http://energy.gov/nepa/downloads/cx-007772-categorical-exclusion-determination Download CX-007787: Categorical Exclusion Determination Line Relocation Project for Farrell Cooper Mining Company CX(s) Applied: B4.13 Date: 01/04/2012 Location(s): Oklahoma Offices(s): Southwestern Power Administration http://energy.gov/nepa/downloads/cx-007787-categorical-exclusion-determination Download CX-007810: Categorical Exclusion Determination 4160 Volt Upgrade Project CX(s) Applied: B1.15, B2.5 Date: 10/05/2011

268

Categorical Exclusion Determinations: Washington | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

August 25, 2010 August 25, 2010 CX-003610: Categorical Exclusion Determination Ross-Lexington Number 1 Access Road Repair Project CX(s) Applied: B1.3 Date: 08/25/2010 Location(s): Cowlitz County, Washington Office(s): Bonneville Power Administration August 25, 2010 CX-003609: Categorical Exclusion Determination Cushman North Fork Skokomish Powerhouse CX(s) Applied: A9 Date: 08/25/2010 Location(s): Tacoma, Washington Office(s): Energy Efficiency and Renewable Energy, Golden Field Office August 25, 2010 CX-003614: Categorical Exclusion Determination Badger Canyon Substation Radio Communication Tower Project CX(s) Applied: B1.7, B1.19 Date: 08/25/2010 Location(s): Benton County, Washington Office(s): Bonneville Power Administration August 24, 2010 CX-003613: Categorical Exclusion Determination

269

Categorical Exclusion Determinations: Strategic Petroleum Reserve Field  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

October 31, 2012 October 31, 2012 CX-009509: Categorical Exclusion Determination Power Monitoring, Communication and Control Upgrade at Bryan Mound Degas Plant (Install) CX(s) Applied: B1.7 Date: 10/31/2012 Location(s): Texas Offices(s): Strategic Petroleum Reserve Field Office October 30, 2012 CX-009510: Categorical Exclusion Determination Strategic Petroleum Reserve Emergency Pipeline and Piping Repair, 2013-2017 CX(s) Applied: B5.4 Date: 10/30/2012 Location(s): CX: none Offices(s): Strategic Petroleum Reserve Field Office October 2, 2012 CX-009216: Categorical Exclusion Determination ADAS System Life Cycle Support, 2012-2015 CX(s) Applied: B1.7 Date: 10/02/2012 Location(s): CX: none Offices(s): Strategic Petroleum Reserve Field Office September 24, 2012 CX-009217: Categorical Exclusion Determination

270

Categorical Exclusion Determinations: Idaho | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

November 28, 2011 November 28, 2011 CX-007772: Categorical Exclusion Determination Idaho National Laboratory Asphalt Repair Project - North Wind Services, LLC CX(s) Applied: B1.3 Date: 11/28/2011 Location(s): Idaho Offices(s): Nuclear Energy, Idaho Operations Office November 22, 2011 CX-007370: Categorical Exclusion Determination Idaho-TRIBE-SHOSHONE-BANNOCK TRIBE OF THE FORT HALL RESERVATION OF IDAHO CX(s) Applied: B2.5, B5.1 Date: 11/22/2011 Location(s): Idaho Offices(s): Energy Efficiency and Renewable Energy November 17, 2011 CX-007364: Categorical Exclusion Determination Provision of Funds to the Kootenai Tribe of Idaho to Purchase the Upper Twin Rivers Conservation Easement CX(s) Applied: B1.25 Date: 11/17/2011 Location(s): Idaho Offices(s): Bonneville Power Administration November 15, 2011

271

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

71 - 20380 of 26,764 results. 71 - 20380 of 26,764 results. Download CX-006661: Categorical Exclusion Determination Repair Flowline at 83-AX-4 CX(s) Applied: B5.2, B5.4 Date: 02/24/2010 Location(s): Casper, Wyoming Office(s): RMOTC http://energy.gov/nepa/downloads/cx-006661-categorical-exclusion-determination Download CX-006799: Categorical Exclusion Determination Energy Efficiency and Renewable Energy Loan/Tech Demo Program - Delphi CX(s) Applied: B5.1 Date: 09/09/2011 Location(s): Auburn Hills, Michigan Office(s): Energy Efficiency and Renewable Energy, Golden Field Office http://energy.gov/nepa/downloads/cx-006799-categorical-exclusion-determination Download CX-006779: Categorical Exclusion Determination Johnson Youth Center Renovation CX(s) Applied: B5.1 Date: 09/09/2011 Location(s): Juneau, Alaska

272

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

11 - 28620 of 28,904 results. 11 - 28620 of 28,904 results. Download CX-003241: Categorical Exclusion Determination Purchase of Jocko Spring Creek Property CX(s) Applied: B1.25 Date: 07/08/2010 Location(s): Lake County, Montana Office(s): Bonneville Power Administration http://energy.gov/nepa/downloads/cx-003241-categorical-exclusion-determination Download CX-003242: Categorical Exclusion Determination Purchase of the Mission Creek Property CX(s) Applied: B1.25 Date: 07/08/2010 Location(s): Lake County, Montana Office(s): Bonneville Power Administration http://energy.gov/nepa/downloads/cx-003242-categorical-exclusion-determination Download CX-003610: Categorical Exclusion Determination Ross-Lexington Number 1 Access Road Repair Project CX(s) Applied: B1.3 Date: 08/25/2010 Location(s): Cowlitz County, Washington

273

Categorical Exclusion Determinations: Kansas | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

September 7, 2010 September 7, 2010 CX-003767: Categorical Exclusion Determination Kansas-County-Leavenworth CX(s) Applied: A9, B2.5, B5.1 Date: 09/07/2010 Location(s): Leavenworth, Kansas Office(s): Energy Efficiency and Renewable Energy September 2, 2010 CX-003826: Categorical Exclusion Determination Project 1712 Repair OF002 Cured-in-Place Pipe Liner Near AICO Inlet CX(s) Applied: B6.1 Date: 09/02/2010 Location(s): Kansas Office(s): Kansas City Site Office, NNSA-Headquarters September 1, 2010 CX-003863: Categorical Exclusion Determination Design and Demonstration of an Advanced Agricultural Feedstock Supply System for Lignocellulosic Bioenergy Production CX(s) Applied: A9, B3.6, B5.1 Date: 09/01/2010 Location(s): Hugoton, Kansas Office(s): Energy Efficiency and Renewable Energy, Golden Field Office

274

Categorical Exclusion Determinations: Environmental Management | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

May 4, 2011 May 4, 2011 CX-005761: Categorical Exclusion Determination 707-C Storm Drain Repairs CX(s) Applied: B1.3 Date: 05/04/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office April 28, 2011 CX-005765: Categorical Exclusion Determination Feed Pump Flush Water Connection/Lifting Bail Interference (General - F/H Tank Farms) CX(s) Applied: B1.3 Date: 04/28/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office April 28, 2011 CX-005892: Categorical Exclusion Determination Columbia River Inter-Tidal Fish Commission Use of White Bluffs Boat Launch and Hanford Town Boat Ramp for Salmon Tagging CX(s) Applied: B3.8 Date: 04/28/2011 Location(s): Richland, Washington Office(s): Environmental Management, Office of River Protection-Richland

275

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

9, 2012 9, 2012 CX-008639: Categorical Exclusion Determination Establish Laydown Yard East of 281-3F CX(s) Applied: B1.15 Date: 05/29/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office May 29, 2012 CX-008638: Categorical Exclusion Determination Excavate to Repair Underground Domestic Water Leak between Tanks 5 and 7 CX(s) Applied: B1.3 Date: 05/29/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office May 29, 2012 CX-008637: Categorical Exclusion Determination Operation and Maintenance of Inductively Coupled Plasma Mass Spectrometry Method in 773, B142 CX(s) Applied: B3.6 Date: 05/29/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office May 29, 2012 CX-008636: Categorical Exclusion Determination Analysis of Organic Species by Gas Chromatography (GC) and Gas

276

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7, 2011 7, 2011 CX-005173: Categorical Exclusion Determination Roof Replacement/Repair, Gutters, and Downspouts CX(s) Applied: B5.1 Date: 01/27/2011 Location(s): Northampton County, Pennsylvania Office(s): Energy Efficiency and Renewable Energy, Golden Field Office January 27, 2011 CX-005127: Categorical Exclusion Determination Philadelphia (Pennsylvania): Energy Loan to Community Legal Services for the Erie Avenue Office CX(s) Applied: B5.1 Date: 01/27/2011 Location(s): Philadelphia, Pennsylvania Office(s): Energy Efficiency and Renewable Energy, Golden Field Office January 27, 2011 CX-005126: Categorical Exclusion Determination Rural Electric Cooperative Geothermal Development Electric and Agriculture CX(s) Applied: A9, B3.1, B5.1, B5.12 Date: 01/27/2011 Location(s): Oregon

277

FE Categorical Exclusions | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

21, 2010 21, 2010 CX-002830: Categorical Exclusion Determination Repairs to Men?s Bathroom in West Hackberry Building 302 CX(s) Applied: B1.3 Date: 06/21/2010 Location(s): West Hackberry, Louisiana Office(s): Fossil Energy, Strategic Petroleum Reserve Field Office June 21, 2010 CX-002829: Categorical Exclusion Determination West Hackberry Brine Disposal Wells Control Systems Upgrade CX(s) Applied: B1.7 Date: 06/21/2010 Location(s): West Hackberry, Louisiana Office(s): Fossil Energy, Strategic Petroleum Reserve Field Office June 18, 2010 CX-002733: Categorical Exclusion Determination Computer Simulation and Experimental Study on Novel Chromium-Based High Temperature Alloys CX(s) Applied: B3.6 Date: 06/18/2010 Location(s): Baton Rouge, Louisiana Office(s): Fossil Energy, National Energy Technology Laboratory

278

Categorical Exclusion Determinations: South Carolina | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

March 18, 2010 March 18, 2010 CX-001311: Categorical Exclusion Determination South Carolina Clean Green Investment Incentives - Solar Initiatives CX(s) Applied: B5.1 Date: 03/18/2010 Location(s): Kingstree, South Carolina Office(s): Energy Efficiency and Renewable Energy, National Energy Technology Laboratory March 18, 2010 CX-001365: Categorical Exclusion Determination Repair Domestic Water Line Near Entrance to 717-F CX(s) Applied: B1.3 Date: 03/18/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office March 17, 2010 CX-001241: Categorical Exclusion Determination Wellford Landfill Methane and Greenhouse Gas to Energy Project CX(s) Applied: A9 Date: 03/17/2010 Location(s): Spartanburg County, South Carolina Office(s): Energy Efficiency and Renewable Energy, Golden Field Office

279

Colorado | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

January 9, 2012 January 9, 2012 Transmission Forum Agenda - February 2012 December 21, 2011 CX-007391: Categorical Exclusion Determination Time-lapse Joint Inversion of Geophysical Data and its Application to Geothermal Prospecting GEODE CX(s) Applied: A9, B3.1, B3.6 Date: 12/21/2011 Location(s): Colorado Offices(s): Golden Field Office December 21, 2011 CX-007389: Categorical Exclusion Determination Advances in Hydrogeochemical Indicators for the Discovery of New Geothermal Resources in the Great Basin CX(s) Applied: A9, B3.6 Date: 12/21/2011 Location(s): Colorado Offices(s): Golden Field Office December 20, 2011 CX-007461: Categorical Exclusion Determination High Resolution 3-dimensional Laser Imaging for Inspection, Maintenance, Repair and Operations - Phase II CX(s) Applied: B3.6

280

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

41 - 7250 of 28,560 results. 41 - 7250 of 28,560 results. Download CX-010621: Categorical Exclusion Determination Pittsburgh Site Wide Exterior Door Repair/Replacement Project CX(s) Applied: B2.1, B2.5 Date: 07/17/2013 Location(s): Pennsylvania Offices(s): National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-010621-categorical-exclusion-determination Download CX-010817: Categorical Exclusion Determination Technology Integration Program - Field Trial - Site Three CX(s) Applied: A9 Date: 08/01/2013 Location(s): Texas Offices(s): National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-010817-categorical-exclusion-determination Download CX-010819: Categorical Exclusion Determination Technology Integration Program - Field Trial - Site Three CX(s) Applied: B3.1, B3.6

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Categorical Exclusion Determinations: Western Area Power  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

April 1, 2013 April 1, 2013 CX-010106: Categorical Exclusion Determination Flaming Gorge Microwave Site Communications Building Access Road Repairs CX(s) Applied: B1.3 Date: 04/01/2013 Location(s): Utah Offices(s): Western Area Power Administration-Rocky Mountain Region March 26, 2013 CX-010105: Categorical Exclusion Determination Urban Transmission Line Danger Tree Management CX(s) Applied: B1.3 Date: 03/26/2013 Location(s): Colorado, Colorado, Colorado, Colorado, Wyoming Offices(s): Western Area Power Administration-Rocky Mountain Region January 23, 2013 CX-009804: Categorical Exclusion Determination Kersey West Switching Station Interconnection Kiowa Creek - Welc 115 Kilovolt Transmission Line CX(s) Applied: B4.1, B4.11 Date: 01/23/2013 Location(s): Colorado Offices(s): Western Area Power Administration-Rocky Mountain Region

282

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5, 2011 5, 2011 CX-007153: Categorical Exclusion Determination Glen Canyon substation Transformer Addition CX(s) Applied: B4.6 Date: 05/05/2011 Location(s): Coconino County, Arizona Office(s): Western Area Power Administration-Desert Southwest Region May 5, 2011 CX-005852: Categorical Exclusion Determination Stegall-Wayside 230 Kilovolt Access Road Extension CX(s) Applied: B1.13 Date: 05/05/2011 Location(s): Dawes County, Wyoming Office(s): Western Area Power Administration-Rocky Mountain Region May 5, 2011 CX-005847: Categorical Exclusion Determination Rocky Reach - Maple Valley Access Road Repair CX(s) Applied: B1.3 Date: 05/05/2011 Location(s): King County, Washington Office(s): Bonneville Power Administration May 5, 2011 CX-005845: Categorical Exclusion Determination

283

Categorical Exclusion Determinations: B1.3 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

September 28, 2011 September 28, 2011 CX-006955: Categorical Exclusion Determination Repair Radiological Fixative Coatings in F Tank Farm CX(s) Applied: B1.3 Date: 09/28/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Sandia Site Office September 28, 2011 CX-006952: Categorical Exclusion Determination Install Two New Steam Line Poles to Replace Poles # K164 and K165 in 105-K Area CX(s) Applied: B1.3 Date: 09/28/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Sandia Site Office September 22, 2011 CX-006884: Categorical Exclusion Determination Replace Big Hill Raw Water Intake Structure Screen Wash Piping CX(s) Applied: B1.3 Date: 09/22/2011 Location(s): Big Hill, Texas Office(s): Strategic Petroleum Reserve Field Office, Sandia Site Office

284

Categorical Exclusion Determinations: South Carolina | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

March 28, 2011 March 28, 2011 CX-005843: Categorical Exclusion Determination Upgrade Heating, Ventilation, and Air Conditioner Supply and D-119/120 Lab Mods, 735-A CX(s) Applied: B1.15 Date: 03/28/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office March 23, 2011 CX-005855: Categorical Exclusion Determination Sidewalks Repair at 704-23K and 701-12K CX(s) Applied: B1.13 Date: 03/23/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office March 23, 2011 CX-005854: Categorical Exclusion Determination Building 705-A Renovations CX(s) Applied: B1.15 Date: 03/23/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office March 23, 2011

285

Categorical Exclusion Determinations: Idaho Operations Office | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

November 28, 2011 November 28, 2011 CX-007774: Categorical Exclusion Determination Rensselaer Infrastructure Upgrade to Enhance Research and Education in Nuclear Engineering - Rensselaer Polytechnic Institute CX(s) Applied: B3.6 Date: 11/28/2011 Location(s): New York Offices(s): Nuclear Energy, Idaho Operations Office November 28, 2011 CX-007773: Categorical Exclusion Determination An Integrated Upgrade of Scientific Equipment for Strengthening the Research and Education in Nuclear Energy at the Ohio State University CX(s) Applied: B1.2, B3.6 Date: 11/28/2011 Location(s): Ohio Offices(s): Nuclear Energy, Idaho Operations Office November 28, 2011 CX-007772: Categorical Exclusion Determination Idaho National Laboratory Asphalt Repair Project - North Wind Services, LLC CX(s) Applied: B1.3

286

Categorical Exclusion Determinations: B1.3 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

December 13, 2011 December 13, 2011 CX-007437: Categorical Exclusion Determination Routine Site Activities at the Shoal, Nevada, Site CX(s) Applied: B1.3, B3.1 Date: 12/13/2011 Location(s): Nevada Offices(s): Legacy Management December 13, 2011 CX-007443: Categorical Exclusion Determination Routine Site Activities at the Shirley Basin South, Wyoming, Disposal Site CX(s) Applied: B1.3, B1.11, B1.20, B3.1 Date: 12/13/2011 Location(s): Wyoming Offices(s): Legacy Management December 13, 2011 CX-007442: Categorical Exclusion Determination Routine Maintenance Activities at the Grand Junction, Colorado, Calibration Model Facility CX(s) Applied: B1.3, B1.24 Date: 12/13/2011 Location(s): Colorado Offices(s): Legacy Management December 5, 2011 CX-007511: Categorical Exclusion Determination Record of Categorical Exclusion for Repair Erosion Problems at Big Hill Raw

287

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81 - 8590 of 29,416 results. 81 - 8590 of 29,416 results. Download CX-006405: Categorical Exclusion Determination 707-C Storm Drain Repairs CX(s) Applied: B1.3 Date: 05/16/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-006405-categorical-exclusion-determination Download CX-000891: Categorical Exclusion Determination Handling of Bulk Background Materials CX(s) Applied: B3.6 Date: 02/12/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-000891-categorical-exclusion-determination Download CX-000893: Categorical Exclusion Determination Benchtop Distillation and Recovery of Volatile Solvents CX(s) Applied: B3.6

288

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

61 - 26970 of 28,904 results. 61 - 26970 of 28,904 results. Download CX-010836: Categorical Exclusion Determination Subcontractor Roof Repair at 717-12S CX(s) Applied: B1.3 Date: 08/01/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-010836-categorical-exclusion-determination Download CX-010837: Categorical Exclusion Determination Disassembly, Relocation, and Reassembly of a Metal-framed Quonset Hut CX(s) Applied: B1.22 Date: 08/01/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-010837-categorical-exclusion-determination Download CX-010838: Categorical Exclusion Determination Raman and Absorption Spectroscopy CX(s) Applied: B3.6 Date: 07/31/2013 Location(s): South Carolina

289

Categorical Exclusion Determinations: South Carolina | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

August 14, 2012 August 14, 2012 CX-009121: Categorical Exclusion Determination Roof Repair at 105-C Disassembly CX(s) Applied: B1.3 Date: 08/14/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office August 14, 2012 CX-009120: Categorical Exclusion Determination Analytical Support for Alternate Feed Stock-2 (AFS-2) CX(s) Applied: B3.6 Date: 08/14/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office August 14, 2012 CX-009119: Categorical Exclusion Determination Well Abandonment and Replacement Well Installation in N-Area CX(s) Applied: B3.1 Date: 08/14/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office August 14, 2012 CX-009118: Categorical Exclusion Determination Sludge Batch 8 Qualification: Washing and Defense Waste Processing Facility

290

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

11 - 19220 of 26,764 results. 11 - 19220 of 26,764 results. Download CX-006719: Categorical Exclusion Determination Casing Drilling Test CX(s) Applied: B1.3, B3.7, B5.12 Date: 05/17/2011 Location(s): Casper, Wyoming Office(s): RMOTC http://energy.gov/nepa/downloads/cx-006719-categorical-exclusion-determination Download CX-006659: Categorical Exclusion Determination Repair Flowline 100 Feet North of 71-3-SX-3 CX(s) Applied: B5.2, B5.4 Date: 02/16/2010 Location(s): Casper, Wyoming Office(s): RMOTC http://energy.gov/nepa/downloads/cx-006659-categorical-exclusion-determination Download CX-000681: Categorical Exclusion Determination Materials and Fuels Complex-Experimental Breeder Reactor-II Sodium Removal/Resource Conservation and Recovery Act Closure Activities CX(s) Applied: B6.1 Date: 01/20/2009

291

Categorical Exclusion Determinations: Savannah River Operations Office |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

May 16, 2011 May 16, 2011 CX-006405: Categorical Exclusion Determination 707-C Storm Drain Repairs CX(s) Applied: B1.3 Date: 05/16/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office May 13, 2011 CX-006406: Categorical Exclusion Determination Silver Chloride Injection at the F Area Hazardous Waste Management Facilities Barrier Wall CX(s) Applied: B6.9 Date: 05/13/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office May 12, 2011 CX-006407: Categorical Exclusion Determination Removal of Inactive Chromate Water Isolation Valves CRW-V-170 and CRW-V-175 and Installation of 3 Inch Blind Flanges for F-area New Hill CX(s) Applied: B1.3 Date: 05/12/2011 Location(s): Aiken, South Carolina

292

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

, 2013 , 2013 CX-010820: Categorical Exclusion Determination Technology Integration Program - Field Trial - Site Three CX(s) Applied: B3.1, B3.6 Date: 08/01/2013 Location(s): Texas Offices(s): National Energy Technology Laboratory August 1, 2013 CX-010837: Categorical Exclusion Determination Disassembly, Relocation, and Reassembly of a Metal-framed Quonset Hut CX(s) Applied: B1.22 Date: 08/01/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 1, 2013 CX-010836: Categorical Exclusion Determination Subcontractor Roof Repair at 717-12S CX(s) Applied: B1.3 Date: 08/01/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office August 1, 2013 CX-010819: Categorical Exclusion Determination Technology Integration Program - Field Trial - Site Three

293

Categorical Exclusion Determinations: B1.3 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

July 13, 2010 July 13, 2010 CX-003133: Categorical Exclusion Determination D-Zero Experiment Emergency Generator Fuel Tank Replacement Project CX(s) Applied: B1.3 Date: 07/13/2010 Location(s): Batavia, Illinois Office(s): Fermi Site Office, Science July 12, 2010 CX-003447: Categorical Exclusion Determination Bridge and Access Road Maintenance CX(s) Applied: B1.3 Date: 07/12/2010 Location(s): Snohomish County, Washington Office(s): Bonneville Power Administration July 12, 2010 CX-003137: Categorical Exclusion Determination Repairs to West Hackberry Building 301 Roof CX(s) Applied: B1.3 Date: 07/12/2010 Location(s): West Hackberry, Louisiana Office(s): Fossil Energy, Strategic Petroleum Reserve Field Office July 12, 2010 CX-002979: Categorical Exclusion Determination Oregon Energy Efficiency and Conservation Block Grant Formula - City of

294

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

11 - 9320 of 28,560 results. 11 - 9320 of 28,560 results. Download CX-006247: Categorical Exclusion Determination Relocation of Bayou Choctaw Helipad CX(s) Applied: B1.3 Date: 06/13/2011 Location(s): Iberville Parish, Louisiana Office(s): Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-006247-categorical-exclusion-determination Download CX-000873: Categorical Exclusion Determination Clean, Inspect, and Repair BMT-27 CX(s) Applied: B1.3 Date: 02/11/2010 Location(s): Texas Office(s): Fossil Energy, Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-000873-categorical-exclusion-determination Download CX-000871: Categorical Exclusion Determination West Hackberry Annual Pressure Safety Valve Testing CX(s) Applied: B1.3 Date: 02/05/2010 Location(s): West Hackberry, Louisiana

295

The case for applied astronomy  

Science Journals Connector (OSTI)

......research-article Features The case for applied astronomy Martin Elvis Martin Elvis is an astronomer...Elvis looks at our golden age of astronomy and gives his personal view of what the future may hold for space and astronomy research, as that golden age hits......

Martin Elvis

2014-02-01T23:59:59.000Z

296

apply skills & experience build skills  

E-Print Network (OSTI)

senior apply skills & experience junior build skills sophomore research & execute freshman explore options1 2 3 4 s u p p o r t4-year career action plan parent about the center for career development Remind your student that it is never too soon or too late to seek an internship or summer job. build

Alvarez, Pedro J.

297

Applying Science to Everyday Life  

Science Journals Connector (OSTI)

Applying Science to Everyday Life ... Basic science ideas and their application appear regularly in people’s daily lives. ... It should be the goal of chemistry educators and other teachers of science to provide their students (and others when given the opportunity) with an appreciation of some basic principles. ...

Norbert J. Pienta

2014-11-11T23:59:59.000Z

298

Journal of Applied Ecology 2004  

E-Print Network (OSTI)

herbivores provide goods and income to rural communities, have major impacts on land use and habitats-Bianchet REVIEW The management of wild large herbivores to meet economic, conservation and environmental is applied to their management across the globe. To be effective, however, management has to be science

Festa-Bianchet, Marco

299

APPLIED THERMAL ENGINEERING Manuscript Draft  

E-Print Network (OSTI)

the heat pump from the grid during the two hours of electrical peak power · Design of a new heat exchangerAPPLIED THERMAL ENGINEERING Manuscript Draft TITLE: Experimental assessment of a PCM to air heat This paper presents a heat exchanger prototype containing PCM material designed to provide a 1kW heating

Paris-Sud XI, Université de

300

Applied Sustainability Political Science 319  

E-Print Network (OSTI)

1 Applied Sustainability Political Science 319 College of Charleston Spring 2013 Day/Time: TH 1 Address: fisherb@cofc.edu Office: 284 King Street, #206 (Office of Sustainability) Office Hours: by appt sustainability. It will focus on the development of semester-long sustainability projects, from conception

Young, Paul Thomas

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

ASSESSMENT OF INDIVIDUAL VARIATION IN DNA DOUBLE-STRAND BREAK REPAIR CAPACITY IN HUMAN DIPLOID FIBROBLASTS  

NLE Websites -- All DOE Office Websites (Extended Search)

ASSESSMENT OF INDIVIDUAL VARIATION IN DNA DOUBLE-STRAND ASSESSMENT OF INDIVIDUAL VARIATION IN DNA DOUBLE-STRAND BREAK REPAIR CAPACITY IN HUMAN DIPLOID FIBROBLASTS Paul F. Wilson, John M. Hinz, Peter B. Nham, Salustra S. Urbin, Cynthia B. Thomas, Irene M. Jones, and Larry H. Thompson Biosciences Directorate, Lawrence Livermore National Laboratory, Livermore, CA The induction of bi-stranded clustered DNA damage (BCD), which includes direct DNA double-strand breaks (DSBs), is a hallmark of ionizing radiation (IR) exposure. Incorrectly repaired DSBs can cause chromosomal rearrangements and an increased risk of genomic instability and cancer. Because there is polymorphic variation in DNA repair genes and much of this variation is predicted to have a functional impact, healthy people likely vary in their capacity to repair DSBs and other BCD. This project

302

A Protein that Repairs Damage to Cancer Cells | Advanced Photon Source  

NLE Websites -- All DOE Office Websites (Extended Search)

An X-ray Vortex on the Horizon? An X-ray Vortex on the Horizon? How Two Drops Become One Scientists Discover How Nanocluster Contaminants Increase Risk of Spreading Mobile RNA is Poised and Ready Glass Does a Double-Take Science Highlights Archives: 2013 | 2012 | 2011 | 2010 2009 | 2008 | 2007 | 2006 2005 | 2004 | 2003 | 2002 2001 | 2000 | 1998 | Subscribe to APS Science Highlights rss feed A Protein that Repairs Damage to Cancer Cells MAY 5, 2008 Bookmark and Share The ABH2-DNA complex. A team of University of Chicago scientists has shown how two proteins locate and repair damaged genetic material inside cells. Because one of the proteins detects and repairs DNA damage that may result from a certain type of cancer therapy, the researchers raised the possibility of designing a molecule that could interfere with the repair process, making cancer

303

“Synthetic Lethality”: Molecular Co-targeting to Restore the DNA Repair Mechanisms in Prostate Cancer Cells  

Science Journals Connector (OSTI)

To this end, PARP inhibitors are the well-known class of drugs that have recently been proposed to reach synthetic lethality in DNA repair-defective, radio-resistant prostate tumors.

Gennaro Ilardi; Stefania Staibano

2013-01-01T23:59:59.000Z

304

Molecular Pathways: Exploiting Tumor-Specific Molecular Defects in DNA Repair Pathways for Precision Cancer Therapy  

Science Journals Connector (OSTI)

...represent genetic aberrations that are specific to cancer cells and not present in healthy...phenotype, which allows incipient cancer cells to accumulate additional cancer-promoting...break (DSB) repair mechanisms has led to the development of targeted therapeutic...

Felix Dietlein and H. Christian Reinhardt

2014-12-01T23:59:59.000Z

305

Evaluation of versions of electric power grid repair schemes from the results of structural reliability calculations  

Science Journals Connector (OSTI)

A procedure for processing repair claims using the results of an estimate of the structural reliability of the electric grid, the results of the approval of algorithms using the example of a test model, and th...

P. V. Toshchakov; O. M. Kotov; A. F. Kostarev

2013-01-01T23:59:59.000Z

306

Genetic Variation in Base Excision Repair Genes and the Prevalence of Advanced Colorectal Adenoma  

Science Journals Connector (OSTI)

...with dietary factors were adjusted for energy. Statistical analysis. Conditional logistic...Genetic variants that increased repair efficiency may protect against colorectal neoplasia...early-onset colorectal carcinoma in Egypt. Cancer Lett 2000;159:79-86. 45...

Sonja I. Berndt; Wen-Yi Huang; M. Daniele Fallin; Kathy J. Helzlsouer; Elizabeth A. Platz; Joel L. Weissfeld; Timothy R. Church; Robert Welch; Stephen J. Chanock; and Richard B. Hayes

2007-02-01T23:59:59.000Z

307

Repair of Radiation Damage to Deoxyribonucleic Acid in Germinating Spores of Bacillus subtilis  

Science Journals Connector (OSTI)

...Metabolism Repair of Radiation Damage to Deoxyribonucleic...Tsukijii, Tokyo, Japan 1 Present address...in vegetative cells. Radiation-induced single-strand...Tsukijii, Tokyo, Japan Received for publication...in vegetative cells. Radiation-induced single-strand...

Hiroshi Terano; Hiroshi Tanooka; Hajime Kadota

1971-06-01T23:59:59.000Z

308

E-Print Network 3.0 - arthroscopic partial repair Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

Tissue: A Validated Finite Element Model Summary: :364-373, 2005. 2 Arciero, R. A., J. H. Wheeler, J. B. Ryan, and J. T. McBride. Arthroscopic Bankart repair... ., and A. B....

309

MyoD Gene Transfer for Cardiac Repair 2209 J. Clin. Invest.  

E-Print Network (OSTI)

the myogenic determination gene, MyoD, into cardiac granulation (wound repair) tissue. A replica- tion-defective suffer myocardial infarctions have significantly impaired car- diac function. Thus, therapy to induce

Kay, Mark A.

310

Polymorphisms in DNA Repair Genes, Medical Exposure to Ionizing Radiation, and Breast Cancer Risk  

Science Journals Connector (OSTI)

...the role of DSB repair in response to low-dose radiation, particularly the range experienced by women from mammograms and other...breast cancer associated with exposure to low doses of ionizing radiation. Although we specifically designed our questionnaire...

Robert C. Millikan; Jon S. Player; Allan Rene deCotret; Chiu-Kit Tse; and Temitope Keku

2005-10-01T23:59:59.000Z

311

Use of CFRP Overlays to Repair Fatigue Damage in Steel Bridge Girders and Components  

E-Print Network (OSTI)

Fatigue damage in steel girder bridges built prior to the mid-1980s is common due to distortion-induced fatigue. Different repair techniques have been developed and implemented to retrofit bridges of this era with existing fatigue damage...

Gangel, Regan Elisabeth

2012-05-31T23:59:59.000Z

312

USE OF COMPOSITE MATERIALS TO REPAIR STEEL STRUCTURES VULNERABLE TO FATIGUE DAMAGE  

E-Print Network (OSTI)

This study investigates mainly two different topics related to the use of CFRP's for strengthening and repair of steel bridges: the use of CFRP's to prevent damage in fatigue vulnerable welded connections prior to fatigue-crack initiation...

Alemdar, Fatih

2010-01-01T23:59:59.000Z

313

Project: UAF Utilities Waste Line Repairs Ch6 to Ch13 Project No: 2013101 UTWH  

E-Print Network (OSTI)

Project: UAF Utilities Waste Line Repairs Ch6 to Ch13 Project No: 2013101 UTWH Subject: Project Schedule Project Duration: May 27 to August 10, 2014 The sewer line will be constructed in phases

Ickert-Bond, Steffi

314

E-Print Network 3.0 - aortic repair pushing Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

for: aortic repair pushing Page: << < 1 2 3 4 5 > >> 1 Mechanobiology of the Aortic Heart Valve Jonathan T. Butcher1 Summary: ;13:798-803 18. Deck JD, Thubrikar MJ, Schneider...

315

Application of adhesive materials for the repair of acting gas pipelines  

Science Journals Connector (OSTI)

The materials and equipment developed to eliminate damage in the pipelines that transmit hydro-carbons are presented. The ... adhesive materials and processing methods used in the repairs are described.

V. S. Smirnov; N. N. Parakhina; A. F. Murokh…

2010-04-01T23:59:59.000Z

316

Study on Sub-sea Pipelines Hyperbaric Welding Repair under High Air Pressures  

Science Journals Connector (OSTI)

Most Chinese sub-sea pipelines are buried in Bohai Sea less than ... are widely used For the application of offshore pipelines repair, the hyperbaric TIG welding process under high...

Canfeng Zhou; Xiangdong Jiao; Long Xue…

2011-01-01T23:59:59.000Z

317

Unmanned deepwater-line repair system passes full-scale trials  

SciTech Connect

The first ever full-scale tests of an unmanned, deepwater-pipeline repair system were successfully conducted last year off the coast of Italy. The Italian gas-transmission company SNAM tested a submersible automatic system (SAS) sealine repair system at a depth of 600 m. The modular SAS allows sealines to be repaired by installation of the Nuovo Pignone mechanical connector. The system's trials simulated complete repair intervention on the 20-in. Trans mediterranean pipeline and provided unprecedented experience to SNAM and to the other involved in this project. The paper discusses the origin of the idea for the SAS, the design of the system, construction and testing, the first sea trials, final deep sea trials, and future developments.

Venzi, S.; Vienna, A. (SNAM SpA, Milan (Italy))

1993-09-06T23:59:59.000Z

318

Tiny Terminators: New Micro-Robots Assemble, Repair Themselves and Are Surprisingly Strong  

Energy.gov (U.S. Department of Energy (DOE))

Tiny robots that can assemble and repair themselves? Watch a video of Argonne National Laboratory's micro-robots that easily perform tasks that can challenge other robots, including moving objects that are larger than themselves.

319

Low Dose Radiation Induced DNA Damage Signaling and Repair Responses in  

NLE Websites -- All DOE Office Websites (Extended Search)

Induced DNA Damage Signaling and Repair Responses in Induced DNA Damage Signaling and Repair Responses in Human 3-Dimensional Skin Model System Yanrong Su, Jarah Meador and Adayabalam S. Balajee Center for Radiological Research, College of Physicians and Surgeons, Columbia University, 630 West, 168th Street, New York, NY 10032. Exposure to ionizing radiation (IR) inflicts a wide variety of lesions in the genomic DNA. Among them, DNA double strand break (DSB) is considered to be the critical lesion for most of the deleterious radiation effects including carcinogenesis. Much of our knowledge on induction and repair kinetics of DSB has come from studies in two dimensional cell culture systems. However, the damage signaling and repair responses to DSB in tissue microenvironment are largely unknown. Knowledge of tissue responses to

320

Diverless pipeline-repair system passes tests for 20-in. pipe  

SciTech Connect

Full-scale tests of a diverless pipeline repair system have shown its effectiveness for repairing subsea pipelines of up to 20 in. in diameter. The repair principle is based upon a metal-to-metal seal. The pipe end is cold forged to form a flare. The metal-to-metal seal is located on a cone which is part of the mechanical hydraulically actuated connector. The cone is advanced and the metal-to-metal seal is compressed between the cone and the inside diameter of the flare, forming a high integrity pipeline seal. A set of remotely controlled modules was constructed to perform the repair operations, including pipe flaring. A series of onshore and shallow water trials have demonstrated the practicability of these modules and the feasibility of the new tie-in concept for a diverless pipeline repair. A second set of tools has also been designed for pipeline tie-ins which works with the pipeline-repair spread.

Lerique, M.; Thiberge, P. (Elf Aquitaine, Pau (FR)); Wright, N. (British Gas PLC, Newcastle upon Tyne (UK))

1990-05-21T23:59:59.000Z

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Roadmap: Technical and Applied Studies -Computer Technology Applied Computer Security and Forensics Technology -Bachelor of Technical and Applied Studies  

E-Print Network (OSTI)

Roadmap: Technical and Applied Studies - Computer Technology Applied Computer Security (2.000) grade. #12;Roadmap: Technical and Applied Studies - Computer Technology Applied Computer and Forensics Technology - Bachelor of Technical and Applied Studies RE-BTAS-TAS-CTAC Regional College Catalog

Khan, Javed I.

322

Nevada applied ecology group publications  

SciTech Connect

Since January 1972, the Nevada Applied Ecology Information Center (NAEIC), Information Research and Analysis Section, Health and Safety Research Division, Oak Ridge National Laboratory, has provided technical information support to the Nevada Applied Ecology Group (NAEG) relevant to the behavior of specific radionuclides, primarily plutonium and americium, in the environment, with special emphasis on pathways to man. This bibliography represents a summary of the biomedical and environmental studies conducted by the NAEG and its contractors. The bibliography focuses on research sponsored by the NAEG. Subject areas of the publications include cover studies of soil, vegetation, animals, microorganisms, resuspension, and meteorology. All references in this publication are stored in a computerized form that is readily available for searches upon request to NAEG and it contractors. 558 refs.

Chilton, B.D.; Pfuderer, H.A.; Cox, T.L. (Oak Ridge National Lab., TN (USA))

1989-09-01T23:59:59.000Z

323

Intraoperative Sac Pressure Measurement During Endovascular Abdominal Aortic Aneurysm Repair  

SciTech Connect

PurposeIntraoperative sac pressure was measured during endovascular abdominal aortic aneurysm repair (EVAR) to evaluate the clinical significance of sac pressure measurement.MethodsA microcatheter was placed in an aneurysm sac from the contralateral femoral artery, and sac pressure was measured during EVAR procedures in 47 patients. Aortic blood pressure was measured as a control by a catheter from the left brachial artery.ResultsThe systolic sac pressure index (SPI) was 0.87 {+-} 0.10 after main-body deployment, 0.63 {+-} 0.12 after leg deployment (P < 0.01), and 0.56 {+-} 0.12 after completion of the procedure (P < 0.01). Pulse pressure was 55 {+-} 21 mmHg, 23 {+-} 15 mmHg (P < 0.01), and 16 {+-} 12 mmHg (P < 0.01), respectively. SPI showed no significant differences between the Zenith and Excluder stent grafts (0.56 {+-} 0.13 vs. 0.54 {+-} 0.10, NS). Type I endoleak was found in seven patients (15%), and the SPI decreased from 0.62 {+-} 0.10 to 0.55 {+-} 0.10 (P = 0.10) after fixing procedures. Type II endoleak was found in 12 patients (26%) by completion angiography. The SPI showed no difference between type II endoleak positive and negative (0.58 {+-} 0.12 vs. 0.55 {+-} 0.12, NS). There were no significant differences between the final SPI of abdominal aortic aneurysms in which the diameter decreased in the follow-up and that of abdominal aortic aneurysms in which the diameter did not change (0.53 {+-} 0.12 vs. 0.57 {+-} 0.12, NS).ConclusionsSac pressure measurement was useful for instant hemodynamic evaluation of the EVAR procedure, especially in type I endoleaks. However, on the basis of this small study, the SPI cannot be used to reliably predict sac growth or regression.

Ishibashi, Hiroyuki, E-mail: ishibash@aichi-med-u.ac.j [Aichi Medical University Hospital, Department of Vascular Surgery (Japan); Ishiguchi, Tsuneo [Aichi Medical University Hospital, Department of Radiology (Japan); Ohta, Takashi; Sugimoto, Ikuo; Iwata, Hirohide; Yamada, Tetsuya; Tadakoshi, Masao; Hida, Noriyuki; Orimoto, Yuki [Aichi Medical University Hospital, Department of Vascular Surgery (Japan); Kamei, Seiji [Aichi Medical University Hospital, Department of Radiology (Japan)

2010-10-15T23:59:59.000Z

324

Master of Science in Applied Educational Psychology  

E-Print Network (OSTI)

Master of Science in Applied Educational Psychology Distance Education Program A 36-credit hour distance education Selected Courses in Applied Educational Psychology Courses offered via distance education for the Applied Educational Psychology program are taught by faculty with esteemed national

Tennessee, University of

325

Assistant Professor Position In Applied Social Psychology  

E-Print Network (OSTI)

Assistant Professor Position In Applied Social Psychology Applied Social Psychology Program Department of Psychology Colorado State University Job Description and Qualifications The Department of Psychology at Colorado State University invites applications for one tenure- track position in Applied Social

326

Applying Quantum Principles to Psychology  

E-Print Network (OSTI)

This article starts out with a detailed example illustrating the utility of applying quantum probability to psychology. Then it describes several alternative mathematical methods for mapping fundamental quantum concepts (such as state preparation, measurement, state evolution) to fundamental psychological concepts (such as stimulus, response, information processing). For state preparation, we consider both pure states and densities with mixtures. For measurement, we consider projective measurements and positive operator valued measurements. The advantages and disadvantages of each method with respect to applications in psychology are discussed.

Jerome R Busemeyer; Zheng Wang; Andrei Khrennikov; Irina Basieva

2014-05-25T23:59:59.000Z

327

Weatherization and Intergovernmental Program: Apply for Weatherization  

NLE Websites -- All DOE Office Websites (Extended Search)

Apply Apply for Weatherization Assistance to someone by E-mail Share Weatherization and Intergovernmental Program: Apply for Weatherization Assistance on Facebook Tweet about Weatherization and Intergovernmental Program: Apply for Weatherization Assistance on Twitter Bookmark Weatherization and Intergovernmental Program: Apply for Weatherization Assistance on Google Bookmark Weatherization and Intergovernmental Program: Apply for Weatherization Assistance on Delicious Rank Weatherization and Intergovernmental Program: Apply for Weatherization Assistance on Digg Find More places to share Weatherization and Intergovernmental Program: Apply for Weatherization Assistance on AddThis.com... Plans, Implementation, & Results Weatherization Assistance Program Weatherization Services

328

WHERE MULTIFUNCTIONAL DNA REPAIR PROTEINS MEET: MAPPING THE INTERACTION DOMAINS BETWEEN XPG AND WRN  

SciTech Connect

The rapid recognition and repair of DNA damage is essential for the maintenance of genomic integrity and cellular survival. Multiple complex and interconnected DNA damage responses exist within cells to preserve the human genome, and these repair pathways are carried out by a specifi c interplay of protein-protein interactions. Thus a failure in the coordination of these processes, perhaps brought about by a breakdown in any one multifunctional repair protein, can lead to genomic instability, developmental and immunological abnormalities, cancer and premature aging. This study demonstrates a novel interaction between two such repair proteins, Xeroderma pigmentosum group G protein (XPG) and Werner syndrome helicase (WRN), that are both highly pleiotropic and associated with inherited genetic disorders when mutated. XPG is a structure-specifi c endonuclease required for the repair of UV-damaged DNA by nucleotide excision repair (NER), and mutations in XPG result in the diseases Xeroderma pigmentosum (XP) and Cockayne syndrome (CS). A loss of XPG incision activity results in XP, whereas a loss of non-enzymatic function(s) of XPG causes CS. WRN is a multifunctional protein involved in double-strand break repair (DSBR), and consists of 3’–5’ DNA-dependent helicase, 3’–5’ exonuclease, and single-strand DNA annealing activities. Nonfunctional WRN protein leads to Werner syndrome, a premature aging disorder with increased cancer incidence. Far Western analysis was used to map the interacting domains between XPG and WRN by denaturing gel electrophoresis, which separated purifi ed full length and recombinant XPG and WRN deletion constructs, based primarily upon the length of each polypeptide. Specifi c interacting domains were visualized when probed with the secondary protein of interest which was then detected by traditional Western analysis using the antibody of the secondary protein. The interaction between XPG and WRN was mapped to the C-terminal region of XPG as well as the C-terminal region of WRN. The physical interaction between XPG and WRN links NER, (made evident by the disease XP) with DSBR, which imparts additional knowledge of the overlapping nature of these two proteins and the previously distinct DNA repair pathways they are associated with. Since genomic integrity is constantly threatened by both endogenous and exogenous (internal and external) damage, understanding the roles of these proteins in coordinating DNA repair processes with replication will signifi cantly further understanding how defects instigate physiological consequences in response to various DNA damaging sources. This ultimately contributes to our understanding of cancer and premature aging.

Rangaraj, K.; Cooper, P.K.; Trego, K.S.

2009-01-01T23:59:59.000Z

329

Repair of mismatched basepairs in mammalian DNA. Progress report, March 1, 1990--February 28, 1991  

SciTech Connect

We have concentrated on three specific areas of our research plan. Our greatest emphasis is on the role of single strand nicks in influencing template strand selection in mismatch repair. We have found, that the ability of a nick in one strand to influence which strand is repaired is not a simple function of distance from the mismatched site but rather that an hot spot where a nick is more likely to have an influence can exist. The second line was production of single-genotype heteroduplexes in order to examine independently the repair of T/G and A/C mispairs within the same sequence context as in our mixed mispair preparations. We have shown preparations of supercoiled heteroduplex can be prepared that were exclusively T/G or exclusively A/C at the mispair site. The third effort has been to understand the difference in repair bias of different cell lines or different transfection conditions as it may relate to different repair systems in the cell. We have identified some of the sources of variation, including cell cycle position. We hope to continue this work to more precisely identify the phase of the cell cycle.

Taylor, J.H.; Hare, J.T.

1991-08-01T23:59:59.000Z

330

Effectiveness of using fibre-reinforced polymer composites for underwater steel pipeline repairs  

Science Journals Connector (OSTI)

Metal pipelines are the most efficient and safe ways for oil and gas transportation over a long distance. At present, almost all pipelines are made by ferrous steel which is sensitive to corrosion at harsh working environments, particularly in the presence of salty water and sulphur ingress media. For years, the most traditionally-credible solution for a damaged steel pipe is to remove the pipe entirely or just a localised damaged section and then replace it by a new one or cover with a steel patch through welding, respectively. Welding or fixing the steel patch is a bulky process especially if the location is underground or underwater. Thus, many researchers have been striving to find effective and safe repair solutions which are light, fast and easy to handle. Numerous literatures have shown that fibre-reinforced polymer-based composites can be effectively used for steel pipe repairs. Considerable research has been carried out on the repair of corroded and gouged pipes incorporating with fibre-reinforced composite wraps. This paper provides a comprehensive review on the use of fibre-reinforced polymer composites for in-air, underground and underwater pipeline repairs. Future developments and prospects on this are also discussed. Critical aspects of technical challenges, benefits and shortcomings in determining the feasibility and suitability for repair systems involving the composites are also presented.

Md Shamsuddoha; Md Mainul Islam; Thiru Aravinthan; Allan Manalo; Kin-tak Lau

2013-01-01T23:59:59.000Z

331

Applied Materials | Open Energy Information  

Open Energy Info (EERE)

Materials Materials Jump to: navigation, search Name Applied Materials Address 3050 Bowers Avenue Place Santa Clara, California Zip 95054 Sector Solar Stock Symbol AMAT Website http://www.appliedmaterials.co Coordinates 37.3775749°, -121.9794416° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.3775749,"lon":-121.9794416,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

332

Microsoft PowerPoint - Bull Shoals U1 repair MSB edit 3.ppt  

NLE Websites -- All DOE Office Websites (Extended Search)

Bull Shoals Unit 1 161kV Bull Shoals Unit 1 161kV Switchyard Feeder Repair Bull Shoals Unit 1 161kV Bull Shoals Unit 1 161kV Switchyard Feeder Repair Switchyard Feeder Repair Mark Dixson Little Rock District US Army Corps US Army Corps of Engineers of Engineers ® ® One Corps Serving The Army and the Nation * Original Equipment - 52 years old. * Unit 1 Oil filled cable pothead failed and exploded on Sept 6 2006. * Resulting fire and fire suppression damaged oil insulated cable system * Minor damage to power plant. Background Background Background US Army Corps US Army Corps of Engineers of Engineers ® ® One Corps Serving The Army and the Nation * Transformer Unit 2 damaged and removed from service. * Cause of fire - Failure of Pothead stress cone assembly and build up of combustible gas * Power Plant lost all power and went in the

333

The Role of DNA double-strand break repair in cellular response to low  

NLE Websites -- All DOE Office Websites (Extended Search)

DNA double-strand break repair in cellular response to low DNA double-strand break repair in cellular response to low dose radiation exposure. David J. Chen Division of Molecular Radiation Biology, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas TX 75390 It has been assumed that molecular pathways that involved in the biological response for low dose of radiation should be similar to those for high dose radiation in general. The low dose-rate effect and DNA double-strand break repair are inextricably linked in mammalian cells. It has been reported that mammalian mutant cells deficient in nonhomologous end join (NHEJ) pathway have little or no cellular recovery when expose to low-dose-rate radiation. Recently, it has also been reported that cells deficient in

334

Emailed Comments of Elizabeth Chimento RE: Pepco Scheduled Line Repair Dec.  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emailed Comments of Elizabeth Chimento RE: Pepco Scheduled Line Emailed Comments of Elizabeth Chimento RE: Pepco Scheduled Line Repair Dec. 1-20, 2006 Emailed Comments of Elizabeth Chimento RE: Pepco Scheduled Line Repair Dec. 1-20, 2006 Docket No. EO-05-01. Regarding the planned line outage, scheduled for Feb. 20 through Mar. 6, I am requesting that the residents near the plant be moved for the duration of the outage to protect their health. Emailed Comments of Elizabeth Chimento RE: Pepco Scheduled Line Repair Dec. 1-20, 2006 More Documents & Publications Letter from Elizabeth Chimento and Poul Hertel to the Federal Energy Regulatory Commission Re: District of Columbia Public Service Commission Emergency Petition and Complaint Docket No. EL05-145-000 Re: Potomac River Generating Station Department of Energy Case No.

335

Structural and Functional Studies on Nucleotide Excision Repair From Recognition to Incision.  

SciTech Connect

Maintenance of the correct genetic information is crucial for all living organisms because mutations are the primary cause of hereditary diseases, as well as cancer and may also be involved in aging. The importance of genomic integrity is underscored by the fact that 80 to 90% of all human cancers are ultimately due to DNA damage. Among the different repair mechanisms that have evolved to protect the genome, nucleotide excision repair (NER) is a universal pathway found in all organisms. NER removes a wide variety of bulky DNA adducts including the carcinogenic cyclobutane pyrimidine dimers induced by UV radiation, benzo(a)pyrene-guanine adducts caused by smoking and the guanine-cisplatin adducts induced by chemotherapy. The importance of this repair mechanism is reflected by three severe inherited diseases in humans, which are due to defects in NER: xeroderma pigmentosum, Cockayne's syndrome and trichothiodystrophy.

Caroline Kisker

2001-01-01T23:59:59.000Z

336

Evaluation of bisphenol E cyanate ester for the resin-injection repair of advanced composites  

SciTech Connect

This thesis is a compilation of a general introduction and literature review that ties together the subsequent chapters which consist of two journal articles that have yet to be submitted for publication. The overall topic relates to the evaluation and application of a new class of cyanate ester resin with unique properties that lend it applicable to use as a resin for injection repair of high glass transition temperature polymer matrix composites. The first article (Chapter 2) details the evaluation and optimization of adhesive properties of this cyanate ester and alumina nanocomposites under different conditions. The second article (Chapter 3) describes the development and evaluation of an injection repair system for repairing delaminations in polymer matrix composites.

Wilber Yaote Lio

2009-12-19T23:59:59.000Z

337

A survey of repair practices for nuclear power plant containment metallic pressure boundaries  

SciTech Connect

The Nuclear Regulatory Commission has initiated a program at the Oak Ridge National Laboratory to provide assistance in their assessment of the effects of potential degradation on the structural integrity and leaktightness of metal containment vessels and steel liners of concrete containments in nuclear power plants. One of the program objectives is to identify repair practices for restoring metallic containment pressure boundary components that have been damaged or degraded in service. This report presents issues associated with inservice condition assessments and continued service evaluations and identifies the rules and requirements for the repair and replacement of nonconforming containment pressure boundary components by welding or metal removal. Discussion topics include base and welding materials, welding procedure and performance qualifications, inspection techniques, testing methods, acceptance criteria, and documentation requirements necessary for making acceptable repairs and replacements so that the plant can be returned to a safe operating condition.

Oland, C.B.; Naus, D.J. [Oak Ridge National Lab., TN (United States)

1998-05-01T23:59:59.000Z

338

Hurricane-damaged Gulf of Mexico pipeline repaired with cold forging  

SciTech Connect

Damage to Texaco Pipeline Inc.'s Eugene Island Pipeline System (EIPS) in last year's Hurricane Andrew prompted a complex repair project unique for the Gulf of Mexico. Damage, suffered when the anchor of a runaway semisubmersible drilling rig crashed into the 20-in. EPIS during the height of the storm, caused the pipeline to fail under pressure within 48 hr. after start-up following the storm. The paper describes the importance of the EIPS; system safety; Andrew's damage; locating the leak; repair options; the chosen system; mechanical bonding; end connectors and ball flanges; and diving operations.

Lewis, G. (Texaco Pipeline Inc., Houma, LA (United States)); DeGruy, P. (Texaco Inc., New Orleans, LA (United States)); Avery, L. (Big Inch Marine Systems Inc., Lafayette, LA (United States))

1993-05-03T23:59:59.000Z

339

Categorical Exclusion Determinations: Michigan | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Michigan Michigan Categorical Exclusion Determinations: Michigan Location Categorical Exclusion Determinations issued for actions in Michigan. DOCUMENTS AVAILABLE FOR DOWNLOAD September 18, 2013 CX-010935: Categorical Exclusion Determination Active, Tailorable Adhesives for Dissimilar Material Bonding, Repair and Reassembly CX(s) Applied: B3.6 Date: 09/18/2013 Location(s): Michigan Offices(s): National Energy Technology Laboratory September 18, 2013 CX-010934: Categorical Exclusion Determination Active, Tailorable Adhesives for Dissimilar Material Bonding, Repair and Reassembly CX(s) Applied: B3.6 Date: 09/18/2013 Location(s): Michigan Offices(s): National Energy Technology Laboratory September 17, 2013 CX-010943: Categorical Exclusion Determination Polyalkylene Glycol Based Lubricant for Light and Medium Duty Vehicle Axles

340

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

51 - 17960 of 28,905 results. 51 - 17960 of 28,905 results. Download CX-003138: Categorical Exclusion Determination Big Hill Buildings 802 and 812 Door Repairs CX(s) Applied: B1.3 Date: 07/20/2010 Location(s): Big Hill, Texas Office(s): Fossil Energy, Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-003138-categorical-exclusion-determination Download CX-003137: Categorical Exclusion Determination Repairs to West Hackberry Building 301 Roof CX(s) Applied: B1.3 Date: 07/12/2010 Location(s): West Hackberry, Louisiana Office(s): Fossil Energy, Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-003137-categorical-exclusion-determination Download CX-003594: Categorical Exclusion Determination Replace Bayou Choctaw Timber Pile Pipe Supports

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81 - 25790 of 28,560 results. 81 - 25790 of 28,560 results. Download CX-010843: Categorical Exclusion Determination Subcontractor Repair of Roof Leak in Rm. F45 at 703-1B CX(s) Applied: B1.3 Date: 07/31/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-010843-categorical-exclusion-determination Download CX-010844: Categorical Exclusion Determination Subcontractor Repair of Leak Over Entry Door #1 at 703-B CX(s) Applied: B1.3 Date: 07/31/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-010844-categorical-exclusion-determination Download CX-010845: Categorical Exclusion Determination Temporary Modification (ETP-TMC-13-01) to Install an Ultrasonic Sound Emitting Device to Control Algae in the H-Retention Basin

342

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

61 - 6770 of 28,905 results. 61 - 6770 of 28,905 results. Download CX-005494: Categorical Exclusion Determination Replacement of the F/H Labs Fire Alarm Control Panel CX(s) Applied: B2.2 Date: 02/28/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-005494-categorical-exclusion-determination Download CX-001368: Categorical Exclusion Determination Repair Domestic Water Leak North of 719-18A CX(s) Applied: B1.3 Date: 03/16/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-001368-categorical-exclusion-determination Download CX-001369: Categorical Exclusion Determination Repair Firewater Line in B-Area East Side (Road C-2) near Post Indicator

343

EVALUATION OF A UAV COMPOSITE WING SPAR REPAIR USING AN EMBEDDED OPTICAL FIBER RAYLEIGH BACK-SCATTERING DISTRIBUTED STRAIN SENSING  

E-Print Network (OSTI)

EVALUATION OF A UAV COMPOSITE WING SPAR REPAIR USING AN EMBEDDED OPTICAL FIBER RAYLEIGH BACK Branch, Tel-Aviv Israel ikressel@iai.co.il ABSTRACT A representing damaged UAV wing spar cap was repaired requirements for UAVs, where the substantiation of structural bonded joint can be based on: "repeatable

Paris-Sud XI, Université de

344

RAP80 Acts Independently of BRCA1 in Repair of Topoisomerase II Poison-Induced DNA Damage  

Science Journals Connector (OSTI)

...Implications for the repair of topoisomerase I-mediated DNA damage. J Biol Chem 2004;279:37343-8. 15 El-Khamisy SF , Saifi GM, Weinfeld M, et al. Defective DNA single-strand break repair in spinocerebellar ataxia with axonal neuropathy-1...

Junko Iijima; Zhihong Zeng; Shunichi Takeda; Yoshihito Taniguchi

2010-11-01T23:59:59.000Z

345

How to Apply for the ENERGY STAR®  

Energy.gov (U.S. Department of Energy (DOE))

Join us to learn about applying for ENERGY STAR Certification in Portfolio Manager. Understand the value of the ENERGY STAR certification, see the step-by-step process of applying, and gain tips to...

346

Repair of Site-Specific DNA Double-Strand Breaks in Barley Occurs via Diverse Pathways Primarily Involving the Sister Chromatid  

Science Journals Connector (OSTI)

...research-article RESEARCH ARTICLES Repair of Site-Specific DNA Double-Strand...various double-strand break repair pathways in the monocot plant...0.307_win32 with UPARSE pipeline (Edgar, 2013). The three...polymorphisms indicative of distinct repair mechanisms. SCE and Mitotic...

Giang T.H. Vu; Hieu X. Cao; Koichi Watanabe; Goetz Hensel; Frank R. Blattner; Jochen Kumlehn; Ingo Schubert

2014-05-29T23:59:59.000Z

347

SMITH, GLEN. Bond Characteristics and Qualifications of Adhesives for Marine Applications and Steel Pipe Repair. (Under the direction of Dr. Sami Rizkalla.)  

E-Print Network (OSTI)

for marine application and repair of steel pipeline. #12;BOND CHARACTERISTICS AND QUALIFICATIONS OF ADHESIVES and Steel Pipe Repair. (Under the direction of Dr. Sami Rizkalla.) Performance of adhesives significantly FOR MARINE APPLICATIONS AND STEEL PIPE REPAIR By Glen E. Smith A thesis submitted to the Graduate Faculty

348

Roadmap: Technical and Applied Studies Computer Technology Applied Computer Security and Forensics Technology  

E-Print Network (OSTI)

Roadmap: Technical and Applied Studies ­ Computer Technology Applied Computer Security-division credit hours #12;Roadmap: Technical and Applied Studies ­ Computer Technology Applied Computer Security and Forensics Technology ­ Bachelor of Technical and Applied Studies [RE-BTAS-TAS-CTAC] Regional College Catalog

Sheridan, Scott

349

Multilayer sulfur-resistant composite metal membranes and methods of making and repairing the same  

DOE Patents (OSTI)

The invention relates to thin, hydrogen-permeable, sulfur-resistant membranes formed from multi-layers of palladium or palladium-alloy coatings on porous, ceramic or metal supports, methods of making these membranes, methods of repairing layers of these membranes and devices that incorporate these membranes.

Way, J. Douglas; Hatlevik, Oyvind

2014-07-15T23:59:59.000Z

350

Investigation of Corrosion Damage and Repair System in a Concrete Jetty Structure  

E-Print Network (OSTI)

Investigation of Corrosion Damage and Repair System in a Concrete Jetty Structure Farid Moradi of the deterioration was reinforcement corrosion, which initiated within few years after the completion of the jetty structure. The structure underwent major corrosion rehabilitation after 7 years of service. Despite the use

Mobasher, Barzin

351

Evaluation of Hardware and Procedures for Astronaut Assembly and Repair of Large Precision Reflectors  

Science Journals Connector (OSTI)

A detailed procedure is presented that enables astronauts in extravehicular activity (EVA) to efficiently assemble and repair large (i.e., greater than 10m-diameter) segmented reflectors, supported by a truss, for space-based optical or radio-frequency ...

Lake Mark S.; Jr Walter L. Heard; Watson Judith J.; Collins Timothy J.

2000-08-01T23:59:59.000Z

352

Latest advances in steam turbine design, blading, repairs, condition assessment, and condenser interaction  

SciTech Connect

This book contains papers presented at a conference on power generation. Topics covered include: a life extension approach for steam turbine blading in Electricite de France fossil plants, and on site 430 MW high pressure reheat turbine shell cracking and distortion repairs.

Rasmussen, D.M. (Turbine Consultants, Inc., Milwaukee, WI (US))

1989-01-01T23:59:59.000Z

353

Evolutionary neural network modeling for forecasting the field failure data of repairable systems  

Science Journals Connector (OSTI)

An accurate product reliability prediction model can not only learn and track the product's reliability and operational performance, but also offer useful information for managers to take follow-up actions to improve the product' quality and cost. This ... Keywords: Genetic algorithms, Neural network model, Reliability prediction, Repairable system

L. Yi-Hui

2007-11-01T23:59:59.000Z

354

The BLM Helicase Is Necessary for Normal DNA Double-Strand Break Repair  

Science Journals Connector (OSTI)

...control, corrected BS, BS, and AT cells in a DSB...EcoRI-cut CIP pUC18 in nuclear extracts are shown. Part...DSB repair assays. The costs of publication of this...abbreviations used are: BS, Blooms syndrome; AT...of linearized supF20 by nuclear extracts from control...

Gregory Langland; James Elliott; Yuling Li; Jenette Creaney; Kathleen Dixon; and Joanna Groden

2002-05-15T23:59:59.000Z

355

Rational Design of Human DNA Ligase Inhibitors that Target Cellular DNA Replication and Repair  

Science Journals Connector (OSTI)

...agents to treat human cancer. Grant support: U.S. NIH grants GM47251, ES12512, and GM57479...Biology of DNA Repair Program grant CA92584 (A.E. Tomkinson...University of Maryland, School of Pharmacy Computer-Aided Drug Design Center...

Xi Chen; Shijun Zhong; Xiao Zhu; Barbara Dziegielewska; Tom Ellenberger; Gerald M. Wilson; Alexander D. MacKerell, Jr.; and Alan E. Tomkinson

2008-05-01T23:59:59.000Z

356

Recombination between a defective retrovirus and homologous sequences in host DNA: reversion by patch repair.  

Science Journals Connector (OSTI)

...transcriptase assay (16). Virus infections were car- ried out with the addition of polybrene...NIH/3T3 cells were infected with the defective virions as described above, but these...infected cell. Thus, we have shown that defective viruses can repair their mutations by...

P Schwartzberg; J Colicelli; S P Goff

1985-03-01T23:59:59.000Z

357

Evaluation of temporary non-code repairs in safety class 3 piping systems  

SciTech Connect

Temporary non-ASME Code repairs in safety class 3 pipe and piping components are permissible during plant operation in accordance with Nuclear Regulatory Commission Generic Letter 90-05. However, regulatory acceptance of such repairs requires the licensee to undertake several timely actions. Consistent with the requirements of GL 90-05, this paper presents an overview of the detailed evaluation and relief request process. The technical criteria encompasses both ductile and brittle piping materials. It also lists appropriate evaluation methods that a utility engineer can select to perform a structural integrity assessment for design basis loading conditions to support the use of temporary non-Code repair for degraded piping components. Most use of temporary non-code repairs at a nuclear generating station is in the service water system which is an essential safety related system providing the ultimate heat sink for various plant systems. Depending on the plant siting, the service water system may use fresh water or salt water as the cooling medium. Various degradation mechanisms including general corrosion, erosion/corrosion, pitting, microbiological corrosion, galvanic corrosion, under-deposit corrosion or a combination thereof continually challenge the pressure boundary structural integrity. A good source for description of corrosion degradation in cooling water systems is provided in a cited reference.

Godha, P.C.; Kupinski, M.; Azevedo, N.F. [Northeast Utilities System, Hartford, CT (United States)

1996-12-01T23:59:59.000Z

358

Overview of NCHRP Design Guideline for EPS-Block Geofoam in Slope Stabilization and Repair  

E-Print Network (OSTI)

1 Overview of NCHRP Design Guideline for EPS-Block Geofoam in Slope Stabilization and Repair David in Construction Applications (EPS 2011 Norway) June 6-8, 2011 #12;2 ABSTRACT This paper presents an overview of the design guideline for the use of expanded polystyrene (EPS)-block geofoam for slope stabilization

Horvath, John S.

359

Development/Plasticity/Repair A Structural MRI Study of Human Brain Development from  

E-Print Network (OSTI)

Development/Plasticity/Repair A Structural MRI Study of Human Brain Development from Birth to 2 Carolina, Chapel Hill, North Carolina 27599-7510 Brain development in the first 2 years after birth and schizophrenia. Knowledge regarding this period is currently quite limited. We studied structural brain

Utah, University of

360

Self-repairing Self-assembled Structures Daniel Arbuckle and Aristides A. G. Requicha  

E-Print Network (OSTI)

1 Self-repairing Self-assembled Structures Daniel Arbuckle and Aristides A. G. Requicha Department.arbuckle@usc.edu, requicha@usc.edu Abstract-- This paper introduces a method by which structures can be self-assembled from by a process analogous to mitosis. I. INTRODUCTION Self-assembly agents have the potential to become an im

Southern California, University of

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Home Maintenance and Repair Owning a home is a major responsibility.  

E-Print Network (OSTI)

Home Maintenance and Repair Owning a home is a major responsibility. Not only do you have the obligation of paying the mortgage each month, but you also have to maintain your home so that it remains a good investment. When talking about taking care of your home, most folks lump home maintenance

362

Analysis and Repair of Name Tagger Errors Heng Ji Ralph Grishman  

E-Print Network (OSTI)

Analysis and Repair of Name Tagger Errors Heng Ji Ralph Grishman Department of Computer Science New feedback from subsequent stages in an information extraction pipeline: name structure parsing, cross' pipelined system archi- tectures, NE tagging is one of the first steps in the pipeline. NE errors adversely

363

CAN-bus based distributed control system for hydraulic turbine blade repairing robot  

Science Journals Connector (OSTI)

A CAN-bus (Controller Area Network) based distributed control system was designed for a mobile on-site hydraulic turbine blade repairing robot (HTBRR). The system is composed of one supervisory station, seven joint servo nodes, and four accessory nodes. ... Keywords: distributed control system, mobile robot, virtual reality

Kangtai Xiang; Zhenguo Sun; Hongjun Dai; Qiang Chen; Jiajun Liu

2010-11-01T23:59:59.000Z

364

Repair of DNA Alkylation Induced in L1210 Leukemia and Murine Bone Marrow by Three Chloroethylnitrosoureas  

Science Journals Connector (OSTI)

...cross-links proceeds much more slowly than does repair of monoadducts; we observed that...cross-links. Further, removal of label does not ensure that the full process of excision...Sartorelli and D. G. Johns (eds.). Handbook of Experimental Pharma cology, Vol. 38...

James D. Ahlgren; Dianna C. Green; Kenneth D. Tew; and Philip S. Schein

1982-07-01T23:59:59.000Z

365

Repairing and maintaining a public bicycle system: the case of Vlib' in Paris1  

E-Print Network (OSTI)

Repairing and maintaining a public bicycle system: the case of Vélib' in Paris1 . Martin Tironi Phd. Valued for their 'planet friendly' character, public bicycle systems have become the hallmark for cities to the worldwide spread of public bicycle schemes (PBS). They now exist in more than 110 cities around the world

Boyer, Edmond

366

Master of Science in Applied Educational Psychology  

E-Print Network (OSTI)

Master of Science in Applied Educational Psychology Distance Education Program A 36-credit hour settings. Selected Courses in Applied Educational Psychology Courses offered via distance education for the Applied Educational Psychology program are taught by faculty with esteemed national and international

Tennessee, University of

367

SYLLABUS--GEOGRAPHY (GEOG)-455 APPLIED CLIMATOLOGY  

E-Print Network (OSTI)

SYLLABUS--GEOGRAPHY (GEOG)-455 APPLIED CLIMATOLOGY Spring 2006 Time: T-R 12:30-1:45 p.m. (BOL B95-455-001-lec@uwm.edu Textbooks: Thompson-Perry, Applied Climatology: principles and practice, (1997, graduate students will prepare a 10 page (2500 word minimum) paper on a project using applied climatology

Saldin, Dilano

368

Department of Applied Physics Introductory Handbook  

E-Print Network (OSTI)

Department of Applied Physics Introductory Handbook Version 2009-05-29 #12;2 Phone: +46 (0) 8 5537 8102 www.aphys.kth.se Visiting address Roslagstullsbacken 21 Delivery address KTH Applied Physics AlbaNova University Center Roslagsvägen 30B 114 19 Stockholm Postal address KTH Applied Physics AlbaNova University

Haviland, David

369

Repair-dependent cell radiation survival and transformation: an integrated theory  

Science Journals Connector (OSTI)

The repair-dependent model of cell radiation survival is extended to include radiation-induced transformations. The probability of transformation is presumed to scale with the number of potentially lethal damages that are repaired in a surviving cell or the interactions of such damages. The theory predicts that at doses corresponding to high survival, the transformation frequency is the sum of simple polynomial functions of dose; linear, quadratic, etc, essentially as described in widely used linear-quadratic expressions. At high doses, corresponding to low survival, the ratio of transformed to surviving cells asymptotically approaches an upper limit. The low dose fundamental- and high dose plateau domains are separated by a downwardly concave transition region. Published transformation data for mammalian cells show the high-dose plateaus predicted by the repair-dependent model for both ultraviolet and ionizing radiation. For the neoplastic transformation experiments that were analyzed, the data can be fit with only the repair-dependent quadratic function. At low doses, the transformation frequency is strictly quadratic, but becomes sigmodial over a wider range of doses. Inclusion of data from the transition region in a traditional linear-quadratic analysis of neoplastic transformation frequency data can exaggerate the magnitude of, or create the appearance of, a linear component. Quantitative analysis of survival and transformation data shows good agreement for ultraviolet radiation; the shapes of the transformation components can be predicted from survival data. For ionizing radiations, both neutrons and x-rays, survival data overestimate the transforming ability for low to moderate doses. The presumed cause of this difference is that, unlike UV photons, a single x-ray or neutron may generate more than one lethal damage in a cell, so the distribution of such damages in the population is not accurately described by Poisson statistics. However, the complete sigmodial dose-response data for neoplastic transformations can be fit using the repair-dependent functions with all parameters determined only from transformation frequency data.

John C Sutherland

2014-01-01T23:59:59.000Z

370

Effective hardware for connection and repair of polyethylene pipelines using ultrasound modification and heat shrinking. Part 5. Aspects of thermistor couplings and components used in gas-pipeline repair  

Science Journals Connector (OSTI)

Aspects of the use of effective hardware for thermistor couplings and components, which are used for thermistor welding in the repair of low- and medium-pressure polyethylene pipelines are investigated. Parameter...

A. E. Kolosov; O. S. Sakharov; V. I. Sivetskii…

2011-07-01T23:59:59.000Z

371

Applied Math and Statistics: Applied Math Minor Curriculum Chart: 2013-2014  

E-Print Network (OSTI)

Applied Math and Statistics: Applied Math Minor Curriculum Chart: 2013-2014 http://matlab-training.soe.ucsc.edu/ PROBABILITY THEORY OR AMS 131 Introduction to Probability Theory CE 107 Mathematical Methods of Systems by the department. #12;Applied Math and Statistics: Applied Math Minor Curriculum Chart: 2013-2014 http

Stuart, Josh

372

Postdoctoral Position in Applied Mathematics Seminar for Applied Mathematics of ETH Zurich  

E-Print Network (OSTI)

Postdoctoral Position in Applied Mathematics Seminar for Applied Mathematics of ETH Z¨urich The Seminar for Applied Mathematics (SAM) of ETH Z¨urich offers a post- doctoral position in applied a competitive salary according to the standards of ETH Z¨urich as well as the opportunity to work

Feichtinger, Hans Georg

373

PhD Position in Applied Mathematics Seminar for Applied Mathematics of ETH Zurich  

E-Print Network (OSTI)

PhD Position in Applied Mathematics Seminar for Applied Mathematics of ETH Z¨urich The Seminar for Applied Mathematics (SAM) of ETH Z¨urich offers a PhD position in applied mathematics. The main research teaching load. The successful candidate will receive a competitive salary according to the standards of ETH

Feichtinger, Hans Georg

374

Applied Intellectual Capital AIC | Open Energy Information  

Open Energy Info (EERE)

Zip: 94501-1010 Product: Applied Intellectual Capital (AIC) was founded in 1999 to fund technology development in clean energy, clean water and sustainable resources. References:...

375

Corrections APPLIED PHYSICAL SCIENCES, BIOPHYSICS AND  

E-Print Network (OSTI)

Corrections APPLIED PHYSICAL SCIENCES, BIOPHYSICS AND COMPUTATIONAL BIOLOGY Correction gene, MyHC-IIb, which is thought under most circumstances not to be expressed. The physiological

Spudich, James A.

376

Applied Films Corporation | Open Energy Information  

Open Energy Info (EERE)

Name: Applied Films Corporation Place: Longmont, Colorado Zip: 80504 Sector: Services, Solar Product: Provider of thin film deposition equipment and services, particularly to...

377

Using synthetic DNA interstrand crosslinks to elucidate repair pathways and identify new therapeutic targets for cancer chemotherapy  

Science Journals Connector (OSTI)

One of the prerequisites for studying ICL repair is the availability of defined ICL-containing oligonucleotides. Initially, this was achieved by the reaction of duplex DNA with crosslinking agents (Fig. 1...a). W...

Angelo Guainazzi; Orlando D. Schärer

2010-11-01T23:59:59.000Z

378

Colorado State University Industrial Assessment Center Report CO0564 1 AR No. 1 -Repair Compressed Air Leaks  

E-Print Network (OSTI)

Colorado State University Industrial Assessment Center Report CO0564 1 AR No. 1 - Repair Compressed was then divided by 0.25 hours to convert the energy consumption into kW, so the #12;Colorado State University

379

UCSC EMPLOYEE HOUSING APARTMENTS APPLICATION Rental rates include: rent, refuse collection, common area utilities, groundskeeping services, and repairs and  

E-Print Network (OSTI)

area utilities, groundskeeping services, and repairs and maintenance of the Laureate Court complex. Tenants pay for their own utilities (i.e., electricity, gas, water, telephone and cable services). A $750

California at Santa Cruz, University of

380

A novel role for the transcriptional modulator NusA in DNA repair/damage tolerance pathways in Escherichia coli  

E-Print Network (OSTI)

All organisms must contend with the consequences of DNA damage, induced by a variety of both endogenous and exogenous sources. Mechanisms of DNA repair and DNA damage tolerance are crucial for cellular survival after DNA ...

Cohen, Susan E., Ph. D. Massachusetts Institute of Technology

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Determinants of Aerobic Capacity During Exercise Following Complete Repair of Tetralogy of Fallot with a Transannular Patch  

Science Journals Connector (OSTI)

Exercise capacity and the causes of its limitation following repair of tetralogy of Fallot have been studied in heterogeneous populations. Study populations have been grouped together regardless of the type of re...

N. Mulla; P. Simpson; N. M. Sullivan; S. M. Paridon

1997-09-01T23:59:59.000Z

382

Analysis of the stress-strain state of an air crossing of pipeline in the course of repair  

Science Journals Connector (OSTI)

We propose a procedure for the numerical analysis of the stress-strain state and criteria of its admissible state in the course of repairs of the air crossings of gas mains ... lifting the pipe to a height requir...

I. V. Orynyak; I. V. Lokhman; M. D. Sydor; S. A. Radchenko…

2009-09-01T23:59:59.000Z

383

Combined Haploinsufficiency for ATM and RAD9 as a Factor in Cell Transformation, Apoptosis, and DNA Lesion Repair Dynamics  

E-Print Network (OSTI)

a role in genomic instability and carcinogenesis after DNA damage is induced. Because the effect to haploinsufficiency for proteins involved in DNA repair pathways plays a role in genomic instability

384

Gene Expression Pathways Activated and Repair of DNA of Double Strand  

NLE Websites -- All DOE Office Websites (Extended Search)

Pathways Activated and Repair of DNA of Double Strand Pathways Activated and Repair of DNA of Double Strand Breaks (DSBs) Following Low Dose Ionizing Radiation in Human Bronchial Epithelial Cells (HBECs) With and Without Defined Premalignant Oncogenic Changes John Minna University of Texas Southwestern Medical Center at Dallas Abstract We want to determine the effect of low dose ionizing radiation on the molecular progression of lung epithelial cells towards lung cancer. Our endpoints are focused on specific molecular and cellular changes known to be associated with lung cancer development and quantitating those changes as a function of low dose ionizing radiation. We use immortalized human bronchial epithelial cells (HBECs) developed from >40 individuals (including those from current, former, and never smokers, males, females,

385

Connections Between the TCR Proteins XPG and CSB, Repair of Oxidative DNA  

NLE Websites -- All DOE Office Websites (Extended Search)

Connections Between the TCR Proteins XPG and CSB, Repair of Oxidative DNA Connections Between the TCR Proteins XPG and CSB, Repair of Oxidative DNA Base Damage, and the Radio-Adaptive Response Helen Budworth, Brett Haltiwanger, Altaf Sarker, Torsten Grösser, Björn Rydberg, and Priscilla K. Cooper* Life Sciences Division, MailStop 74-157, Lawrence Berkeley National Laboratory, Berkeley, CA 94720; *Corresponding author A key question that is central to accurately assessing human health risks from environmentally relevant low level (low dose, low dose rate) exposures to ionizing radiation is whether cellular responses measured at the higher doses for which there are strong epidemiological health data and the high doses commonly used in laboratory experiments extrapolate in a linear fashion to low doses. Recent data suggest that they may not. For example, low-dose hypersensitivity for

386

Low Dose Radiation Research Program: Checkpoint Responses and Repair of a  

NLE Websites -- All DOE Office Websites (Extended Search)

Checkpoint Responses and Repair of a Broken Chromosome in Budding Checkpoint Responses and Repair of a Broken Chromosome in Budding Yeast. Authors: André Walther, Mreshwar B. Vaze, Anna Malkova, Grzegorz Ira, Xuan Wang, Jung-Ae Kim, Neal Sugawara, James E. Haber Brandeis University, Waltham, Massachusetts We have studied how yeast cells respond to the creation of a single double-strand break (DSB) by using a site-specific endonuclease to create one (or more) DSBs. In collaboration with R. Schroff, M. Licheten and W. Bonner (NIH) we have shown that a single DSB rapidly becomes associated with histone H2AX-phosphorylation (y-H2AX) covering a distance of about 25 kb on either side of the DSB. The drop-off in phosphorylation is not attributable to specific boundary sequences. y-H2AX can be phosphorylated by either ATR (Mec1) or ATM (Tel1) protein kinases. A mutation that removes

387

A Key Step in Repairing DNA Double-Strand Breaks | Advanced Photon Source  

NLE Websites -- All DOE Office Websites (Extended Search)

X-ray Rainbow X-ray Rainbow An Insulating Breakthrough Science Highlights Archives: 2013 | 2012 | 2011 | 2010 2009 | 2008 | 2007 | 2006 2005 | 2004 | 2003 | 2002 2001 | 2000 | 1998 | Subscribe to APS Science Highlights rss feed A Key Step in Repairing DNA Double-Strand Breaks JANUARY 10, 2007 Bookmark and Share The atomic structure of the protein 53BP1 identified by Mayo researchers. (Courtesy: Mayo Clinic) A team of Mayo Clinic researchers has uncovered a key step in the molecular pathway of repairing DNA double-strand breaks. The studies were carried out using the 19-ID beamline (SBC-CAT) at the Advanced Photon Source (APS, Argonne) and the X12-C beamline at the National Synchrotron Light Source (NSLS, Brookhaven National Laboratory). Both the APS and the NSLS are funded by the U.S. Department of Energy's Office of Basic Energy

388

Subterranean barriers, methods, and apparatuses for forming, inspecting, selectively heating, and repairing same  

DOE Patents (OSTI)

A subterranean barrier and method for forming same are disclosed, the barrier including a plurality of casing strings wherein at least one casing string of the plurality of casing strings may be affixed to at least another adjacent casing string of the plurality of casing strings through at least one weld, at least one adhesive joint, or both. A method and system for nondestructively inspecting a subterranean barrier is disclosed. For instance, a radiographic signal may be emitted from within a casing string toward an adjacent casing string and the radiographic signal may be detected from within the adjacent casing string. A method of repairing a barrier including removing at least a portion of a casing string and welding a repair element within the casing string is disclosed. A method of selectively heating at least one casing string forming at least a portion of a subterranean barrier is disclosed.

Nickelson, Reva A. (Shelley, ID); Sloan, Paul A. (Rigby, ID); Richardson, John G. (Idaho Falls, ID); Walsh, Stephanie (Idaho Falls, ID); Kostelnik, Kevin M. (Idaho, ID)

2009-04-07T23:59:59.000Z

389

Full scale experimental analysis of stress states in sleeve repairs of gas pipelines  

Science Journals Connector (OSTI)

This study discusses the experimental determination of stress states in sleeve repairs of underground gas pipelines. Work was done to define the effects of the reduction of pressure during welding, the load and place of positioning clamps, the length of the repair sleeve, and the use of O'ring-based devices to prevent gas leakage. Tests were carried out in reinforcements, welded with internal pressure equal to 60, 80 and 100% of the service pressure. High stresses were generated in tests carried out with short sleeves and O'rings, and occurred once the sleeve was fully welded and the pipeline pressure re-established. Maximum stresses, up to 270 MPa, were generated after about 1 min following closing of venting valves, on tests with artificial gas leaks. From the results of these experimental studies, it is concluded that several operative aspects could be optimised, to minimise the stresses in the reinforcements and to reduce the risk of failures.

M.D Chapetti; J.L Otegui; C Manfredi; C.F Martins

2001-01-01T23:59:59.000Z

390

Influence of old rectangular repair patches on the burst pressure of a gas pipeline  

Science Journals Connector (OSTI)

Seven full scale hydrostatic burst tests were carried out on pipes extracted from an API 5LX52 gas pipeline that contained rectangular and elliptical fillet welded patches and other repairs of different geometries. All breaks took place after widespread yielding. This analysis shows that the patches that generate greater risks are those that: (1) were attached to the pipeline at very low pressure, (2) were placed to repair large defects, (3) are rectangular, long in the direction of the pipe, and narrow, (4) the quality of the weld is doubtful. Based on data reported by In Line Inspection (ILI), of the four conditions mentioned above, only the third can be assessed in order to quantify risks and to schedule replacements.

Pablo Gabriel Fazzini; José Luis Otegui

2006-01-01T23:59:59.000Z

391

Oman India Pipeline: An operational repair strategy based on a rational assessment of risk  

SciTech Connect

This paper describes the development of a repair strategy for the operational phase of the Oman India Pipeline based upon the probability and consequences of a pipeline failure. Risk analyses and cost benefit analyses performed provide guidance on the level of deepwater repair development effort appropriate for the Oman India Pipeline project and identifies critical areas toward which more intense development effort should be directed. The risk analysis results indicate that the likelihood of a failure of the Oman India Pipeline during its 40-year life is low. Furthermore, the probability of operational failure of the pipeline in deepwater regions is extremely low, the major proportion of operational failure risk being associated with the shallow water regions.

German, P.

1996-12-31T23:59:59.000Z

392

Pipeline rehabilitation surveys for prioritizing coat/wrap repairs of old cross-country pipelines  

SciTech Connect

Pipelines which are more than 15--20 years old, and are coated with traditional hot-melt coal tar coat/wrap, generally show marked degradation of their coat wrap over time. This could be due to various reasons. In aggressive soils, re-coating the pipeline becomes imperative. However, primarily due to budgetary constraints, the coat wrap repair of the entire line cannot be undertaken all at one time. It has to be done in phases, depending on resources available. By using the techniques of Current Attenuation Test, supported by Direct Current Voltage Gradient (DCVG) survey and ON/Instant OFF pipe-to-soil potential logging and average current density, one can quickly and fairly accurately identify and prioritize the pipeline sections for immediate coat/wrap repairs.

Bardalai, B.; Tech, B. [Quest Pipeline Services Pvt. Ltd., Assam (India)

1997-09-01T23:59:59.000Z

393

Turbine repair at Nesjavellir geothermal power plant: An Icelandic case study  

Science Journals Connector (OSTI)

Abstract During a quadrennial inspection of a 30 MW Mitsubishi steam turbine at Nesjavellir geothermal power plant, corrosion products were found on the last set of labyrinth packing in the gland seal system which resulted in erosion corrosion of the turbine rotor. The rotor had worn by approximately 8 mm. Because of the tight timeframe of the overhaul, it was decided to repair this failure on site using the experience of the staff and domestic industry. Labyrinth seals were built by a domestic machine shop, decreasing cost and shutdown time dramatically. This article describes the occurring failure and how it was repaired within days with cooperation between the energy company and domestic industry. It further discusses probable causes for such failure and how it may be prevented. The article describes in essence how valuable it can prove to build maintenance knowledge domestically in the geothermal sector.

R.S. Atlason; A. Gunnarsson; R. Unnthorsson

2015-01-01T23:59:59.000Z

394

Low Dose Radiation Research Program: Genetic Control of Repair and Adaptive  

NLE Websites -- All DOE Office Websites (Extended Search)

Repair and Adaptive Responses to Low-level DNA Damage Repair and Adaptive Responses to Low-level DNA Damage James E. Haber Brandeis University Why This Project In order to fully understand mechanisms resulting in effects of low dose, whole system rather than cells must be examined. Although not identical to mammalian systems, simple systems usually have many similarities and give direction for further study of more complex systems. We use the budding yeast, Saccharomyces cerevisiae, as a model system because it is easy to manipulate and its genome is simple and well characterized. Project Goals Examine mechanisms and effects of low dose radiation response for: Genetic recombination mechanisms that lead to genomic instability Genetic factors that affect individual susceptibility to low-dose radiation The adaptive response

395

To: Mansueti, Lawrence Subject: RE: Pepco Scheduled Line Repair Dec. 1-20, 2006  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

From: ecchimento@comcast.net [mailto:ecchimento@comcast.net] Sent: Monday, January 29, 2007 6:28 PM To: Mansueti, Lawrence Subject: RE: Pepco Scheduled Line Repair Dec. 1-20, 2006 Larry, Regarding the planned line outage, scheduled for Feb. 20 through Mar. 6, I am requesting that the residents near the plant be moved for the duration of the outage to protect their health. Would you include this comment also in the ongoing recorded discussion? Thank you. Elizabeth

396

Differential evolution applied for reliability optimization of radial distribution systems  

Science Journals Connector (OSTI)

This paper describes a methodology for reliability enhancement of radial distribution system by determining optimal values of repair times and failure rates of each section. Penalty cost functions have been constructed as function of failure rates and repair times. Constraints on customer and energy based indices, i.e. SAIFI, SAIDI, CAIDI and AENS have been considered. The problem has been decomposed in two stages. One stage determines the optimum failure rates and second stage optimizes repair times satisfying constraints. A population based approach, i.e. differential evolution (DE) has been used as optimization technique. The algorithm has been implemented on a sample test system. Results obtained have been compared with those obtained using particle swarm optimization (PSO) and co-ordinated aggregation based particle swarm optimization techniques (CAPSO).

L.D. Arya; S.C. Choube; Rajesh Arya

2011-01-01T23:59:59.000Z

397

Roadmap: Technical and Applied Studies Fraud Examination  

E-Print Network (OSTI)

Roadmap: Technical and Applied Studies ­ Fraud Examination ­ Bachelor of Technical and Applied of Fraud Examination 3 C COMT 36318 Survey of Information Security, Internet Fraud and Computer Forensics to Fraud Examination 3 C JUS 22100 Basic Interviewing 3 C Major Requirement 3 C See note 2 on page 2

Sheridan, Scott

398

GRANT APPLICATION I am applying for a  

E-Print Network (OSTI)

GRANT APPLICATION I am applying for a: Faculty Research Travel Grant ($2,000 Maximum) The funds University Guidelines. Partnership Grant ($2,000 Maximum) The funds must be applied to costs directly related to travel (airfare, accommodation, and meals). This grant is not intended for general costs

399

UNL Core for Applied Genomics and Ecology  

E-Print Network (OSTI)

UNL Core for Applied Genomics and Ecology Bioinformatics training Roche 454 GS-FLX Registration, Microbiomes, Variant Analysis, Whole Genomes, Transcriptomes Data Analysis and Statistics CAGE database and employer. University of Nebraska-Lincoln*Core for Applied Genomics and Ecology* 323 Filley Hall *Lincoln

Farritor, Shane

400

Acoustic Emission Detection and Prediction of Fatigue Crack Propagation in Composite Patch Repairs Using Neural Networks  

SciTech Connect

An aircraft is subjected to severe structural and aerodynamic loads during its service life. These loads can cause damage or weakening of the structure especially for aging military and civilian aircraft, thereby affecting its load carrying capabilities. Hence composite patch repairs are increasingly used to repair damaged aircraft metallic structures to restore its structural efficiency. This paper presents the results of Acoustic Emission (AE) monitoring of crack propagation in 2024-T3 Clad aluminum panels repaired with adhesively bonded octagonal, single sided boron/epoxy composite patch under tension-tension fatigue loading. Crack propagation gages were used to monitor crack initiation. The identified AE sensor features were used to train neural networks for predicting crack length. The results show that AE events are correlated with crack propagation. AE system was able to detect crack propagation even at high noise condition of 10 Hz loading; that crack propagation signals can be differentiated from matrix cracking signals that take place due to fiber breakage in the composite patch. Three back-propagation cascade feed forward networks were trained to predict crack length based on the number of fatigue cycles, AE event number, and both the Fatigue Cycles and AE events, as inputs respectively. Network using both fatigue cycles and AE event number as inputs to predict crack length gave the best results, followed by Network with fatigue cycles as input, while network with just AE events as input had a greater error.

Okafor, A. Chukwujekwu; Singh, Navdeep; Singh, Navrag [Structural Health Monitoring and NDE Laboratory, Department of Mechanical and Aerospace Engineering, University of Missouri-Rolla, 1870 Miner Circle Rolla MO 65409-0050 (United States)

2007-03-21T23:59:59.000Z

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Characterisation of mechanical and thermal properties of epoxy grouts for composite repair of steel pipelines  

Science Journals Connector (OSTI)

Abstract The mechanical and thermal properties of the grouts are critical to their potential application as infill materials in structural repair. In this paper, the mechanical and thermal behaviour of five epoxy based grouts were investigated to identify their prospects as a component of the composite repair for steel pipelines. The compressive strength and stiffness of the grouts are found to be 52–120 MPa and 1.7–11 GPa, respectively. The tensile, flexural and shear strengths of the grouts are found to be within the ranges of 11–32, 27–53, and 13–30 MPa, respectively. The tensile and flexural moduli range within 3–17, and 4–13 GPa, respectively. Thermal analysis of the grouts suggests that the glass transition temperature (Tg) within 60 and 90 °C which also provide the thermal applicability limits for the grouts in the composite repair of steel pipes. The development of compressive properties of three selected grouts over 28 days period was also investigated as well as the effect of the addition of coarse fillers.

Md Shamsuddoha; Md Mainul Islam; Thiru Aravinthan; Allan Manalo; Kin-tak Lau

2013-01-01T23:59:59.000Z

402

Applied Materials Inc AMAT | Open Energy Information  

Open Energy Info (EERE)

Inc AMAT Inc AMAT Jump to: navigation, search Name Applied Materials Inc (AMAT) Place Santa Clara, California Zip 95052-8039 Sector Solar Product US-based manufacturer of equipment used in solar (silicon, thin-film, BIPV), semiconductor, and LCD markets. References Applied Materials Inc (AMAT)[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Applied Materials Inc (AMAT) is a company located in Santa Clara, California . References ↑ "Applied Materials Inc (AMAT)" Retrieved from "http://en.openei.org/w/index.php?title=Applied_Materials_Inc_AMAT&oldid=342244" Categories: Clean Energy Organizations Companies Organizations Stubs What links here Related changes

403

Applied Materials Wind Turbine | Open Energy Information  

Open Energy Info (EERE)

Wind Turbine Wind Turbine Jump to: navigation, search Name Applied Materials Wind Turbine Facility Applied Materials Sector Wind energy Facility Type Community Wind Facility Status In Service Owner Applied Materials Developer Applied Materials Energy Purchaser Applied Materials Location Gloucester MA Coordinates 42.62895426°, -70.65153122° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.62895426,"lon":-70.65153122,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

404

CX-009719: Categorical Exclusion Determination | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

19: Categorical Exclusion Determination 19: Categorical Exclusion Determination CX-009719: Categorical Exclusion Determination Repair and Line Bryan Mound Brine Tank, BMT-1 CX(s) Applied: B1.3 Date: 12/18/2012 Location(s): Texas Offices(s): Strategic Petroleum Reserve Field Office Subcontractor shall provide all transportation, materials, equipment, supplies, tools, facilities, utilities, labor and supervision required to repair and line the Bryan Mound (BM) brine tank, BMT-1. The tank will be cleaned by others before turning it over to the Subcontractor for repairs. Tasks include welding repair work (if required), welding inspection, tank surface preparation, and lining. CX-009719.pdf More Documents & Publications CX-000873: Categorical Exclusion Determination CX-009213: Categorical Exclusion Determination

405

Categorical Exclusion Determinations: Wyoming | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

March 3, 2010 March 3, 2010 CX-006667: Categorical Exclusion Determination Restoration of 73-SX-10H CX(s) Applied: B6.1 Date: 03/07/2010 Location(s): Casper, Wyoming Office(s): RMOTC February 24, 2010 CX-006661: Categorical Exclusion Determination Repair Flowline at 83-AX-4 CX(s) Applied: B5.2, B5.4 Date: 02/24/2010 Location(s): Casper, Wyoming Office(s): RMOTC February 24, 2010 CX-006655: Categorical Exclusion Determination Coal Bed Methane Gas Separator CX(s) Applied: B3.7, B3.11 Date: 02/24/2010 Location(s): Casper, Wyoming Office(s): RMOTC February 24, 2010 CX-006651: Categorical Exclusion Determination Water Haul Permit Location CX(s) Applied: B1.3, B1.6 Date: 02/11/2010 Location(s): Casper, Wyoming Office(s): RMOTC February 13, 2010 CX-006734: Categorical Exclusion Determination

406

Categorical Exclusion Determinations: RMOTC | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

February 24, 2010 February 24, 2010 CX-006651: Categorical Exclusion Determination Water Haul Permit Location CX(s) Applied: B1.3, B1.6 Date: 02/11/2010 Location(s): Casper, Wyoming Office(s): RMOTC February 16, 2010 CX-006659: Categorical Exclusion Determination Repair Flowline 100 Feet North of 71-3-SX-3 CX(s) Applied: B5.2, B5.4 Date: 02/16/2010 Location(s): Casper, Wyoming Office(s): RMOTC February 13, 2010 CX-006734: Categorical Exclusion Determination ThruBit LWT CX(s) Applied: B3.7, B5.12 Date: 07/13/2010 Location(s): Casper, Wyoming Office(s): RMOTC February 11, 2010 CX-006648: Categorical Exclusion Determination Change Out Down Guy on Power Pole East of B-1-33 CX(s) Applied: B1.3 Date: 02/11/2010 Location(s): Casper, Wyoming Office(s): RMOTC February 11, 2010 CX-006657: Categorical Exclusion Determination

407

How to Apply??? Students wishing to apply for a position in the  

E-Print Network (OSTI)

as grounds maintenance and landscaping responsibilities. Work Schedule: The workHow to Apply??? Students wishing to apply for a position in the landscape your application package to: Cranbrook Educational Community Landscape Horticulture

408

Vehicle Technologies Office: Applied Battery Research  

Energy.gov (U.S. Department of Energy (DOE))

Applied battery research addresses the barriers facing the lithium-ion systems that are closest to meeting the technical energy and power requirements for hybrid electric vehicle (HEV) and electric...

409

Applied Field Research Initiative Deep Vadose Zone  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Applied Field Research Initiative Applied Field Research Initiative Deep Vadose Zone Located on the Hanford Site in Richland, Washington, the Deep Vadose Zone Applied Field Research Initiative (DVZ AFRI) was established to protect water resources by addressing the challenge of preventing contamination in the deep vadose zone from reaching groundwater. Led by the Pacific Northwest National Laboratory, the Initiative is a collaborative effort that leverages Department of Energy (DOE) investments in basic science and applied research and the work of site contractors to address the complex deep vadose zone contamination challenges. Challenge Many vadose zone environments within the DOE complex consist of complex stratified layers of unconsolidated and water-unsaturated sediments that are, in many places, con-

410

Roadmap: Applied Engineering Applied Engineering and Technology Management Bachelor of Science  

E-Print Network (OSTI)

Roadmap: Applied Engineering ­ Applied Engineering and Technology Management ­ Bachelor of Science [AT-BS-AENG-AETM] College of Applied Engineering, Sustainability and Technology Catalog Year: 2013­2014 Page 1 of 2 | Last Updated: 28-Feb-13/JS This roadmap is a recommended semester-by-semester plan

Sheridan, Scott

411

Roadmap: Applied Engineering Applied Engineering and Technology Management Bachelor of Science  

E-Print Network (OSTI)

Roadmap: Applied Engineering ­ Applied Engineering and Technology Management ­ Bachelor of Science [AT-BS-AENG-AETM] College of Applied Engineering, Sustainability and Technology Catalog Year: 2012­2013 Page 1 of 2 | Last Updated: 21-May-12/JS This roadmap is a recommended semester-by-semester plan

Sheridan, Scott

412

Roadmap: Technical and Applied Studies -Computer Technology General -Bachelor of Technical and Applied Studies  

E-Print Network (OSTI)

Roadmap: Technical and Applied Studies - Computer Technology General - Bachelor of Technical;Roadmap: Technical and Applied Studies - Computer Technology General - Bachelor of Technical and Applied-Mar-14/JSK This roadmap is a recommended semester-by-semester plan of study for this major. However

Khan, Javed I.

413

A fluorescence method to detect photo-activated repair of UV-induced DNA damage in marine organisms  

SciTech Connect

After UV exposure, marine microorganisms may re-activate their photosynthetic systems or regain their pre-exposure metabolic rates, but they will not long survive, nor grow or reproduce, if they cannot repair DNA or ERN damage. Several repair mechanisms, including nucleotide excision repair and photo-reactivation, are known in terrestrial organisms, but there is little information on either process in marine microorganisms. Photo-reactivation may be especially important near the ocean surface where a few meters difference in vertical position or a few hours difference in time may alleviate UV-irradiation stress yet still provide sufficient light for photoactivated repair processes. We have developed a relatively simple, sensitive method to measure the activity of the photo-reactivation enzyme, photolyase, by fluorometry. UV irradiation causes adjacent thymine nucleotides in DNA to form cyclobutane dimers. Photolyase attaches to the dimerized DNA then breaks the dimers in a reaction catalyzed by visible light, thereby allowing restoration of cross-strand base pairing. Our assay for photolyase activity involves a dimerized synthetic DNA and DNA-specific fluorochromes with affinity for thymine-rich regions of DNA. When thymine dimers are present, fluorescence of these dyes is reduced. As dimers are repaired, fluorescence increases, allowing us to demonstrate the presence of photolyase and measure its activity using conventional fluorometers available in most marine laboratories. Photo-reactivation activity has been unambiguously demonstrated in samples of coastal seawater. In preliminary investigations, cells taken from surface slicks did not have enhanced photo-repair capabilities relative to cells collected 5 meters below the surface. Additional tests of the method and measurements of photo-repair activities of surface and subsurface organisms will be made during the SLIX-89 Surface Microlayer Experiment in October 1989.

Carlson, D.J.; Mordy, C.W.; Nelson, K. (Oregon State Univ., Corvallis (United States))

1990-01-09T23:59:59.000Z

414

The endoperoxide ascaridol shows strong differential cytotoxicity in nucleotide excision repair-deficient cells  

SciTech Connect

Targeting synthetic lethality in DNA repair pathways has become a promising anti-cancer strategy. However little is known about such interactions with regard to the nucleotide excision repair (NER) pathway. Therefore, cell lines with a defect in the NER genes ERCC6 or XPC and their normal counterparts were screened with 53 chemically defined phytochemicals isolated from plants used in traditional Chinese medicine for differential cytotoxic effects. The screening revealed 12 drugs that killed NER-deficient cells more efficiently than proficient cells. Five drugs were further analyzed for IC{sub 50} values, effects on cell cycle distribution, and induction of DNA damage. Ascaridol was the most effective compound with a difference of > 1000-fold in resistance between normal and NER-deficient cells (IC{sub 50} values for cells with deficiency in ERCC6: 0.15 ?M, XPC: 0.18 ?M, and normal cells: > 180 ?M). NER-deficiency combined with ascaridol treatment led to G2/M-phase arrest, an increased percentage of subG1 cells, and a substantially higher DNA damage induction. These results were confirmed in a second set of NER-deficient and -proficient cell lines with isogenic background. Finally, ascaridol was characterized for its ability to generate oxidative DNA damage. The drug led to a dose-dependent increase in intracellular levels of reactive oxygen species at cytotoxic concentrations, but only NER-deficient cells showed a strongly induced amount of 8-oxodG sites. In summary, ascaridol is a cytotoxic and DNA-damaging compound which generates intracellular reactive oxidative intermediates and which selectively affects NER-deficient cells. This could provide a new therapeutic option to treat cancer cells with mutations in NER genes. -- Highlights: ? Thousand-fold higher Ascaridol activity in NER-deficient versus proficient cells. ? Impaired repair of Ascaridol-induced oxidative DNA damage in NER-deficient cells. ? Selective activity of Ascaridol opens new therapy options in NER-deficient tumors.

Abbasi, Rashda [Division of Epigenomics and Cancer Risk Factors, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany)] [Division of Epigenomics and Cancer Risk Factors, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Efferth, Thomas [Institute of Pharmacy und Biochemistry, Johannes Gutenberg University, Staudinger Weg 5, 55128 Mainz (Germany)] [Institute of Pharmacy und Biochemistry, Johannes Gutenberg University, Staudinger Weg 5, 55128 Mainz (Germany); Kuhmann, Christine [Division of Epigenomics and Cancer Risk Factors, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany)] [Division of Epigenomics and Cancer Risk Factors, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Opatz, Till [Institute of Organic Chemistry, Johannes Gutenberg University, Duesbergweg 10-14, 55128 Mainz (Germany)] [Institute of Organic Chemistry, Johannes Gutenberg University, Duesbergweg 10-14, 55128 Mainz (Germany); Hao, Xiaojiang [Kunming Institute of Botany, Chinese Academy of Sciences, Kunming 650204 (China)] [Kunming Institute of Botany, Chinese Academy of Sciences, Kunming 650204 (China); Popanda, Odilia, E-mail: o.popanda@dkfz.de [Division of Epigenomics and Cancer Risk Factors, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany)] [Division of Epigenomics and Cancer Risk Factors, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Schmezer, Peter [Division of Epigenomics and Cancer Risk Factors, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany)] [Division of Epigenomics and Cancer Risk Factors, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany)

2012-03-15T23:59:59.000Z

415

Development and validation of nondestructive inspection techniques for composite doubler repairs on commercial aircraft  

SciTech Connect

Composite doublers, or repair patches, provide an innovative repair technique which can enhance the way aircraft are maintained. Instead of riveting multiple steel or aluminum plates to facilitate an aircraft repair, it is possible to bond a single boron-epoxy composite doubler to the damaged structure. In order for the use of composite doublers to achieve widespread use in the civil aviation industry, it is imperative that methods be developed which can quickly and reliably assess the integrity of the doubler. In this study, a specific composite application was chosen on an L-1011 aircraft in order to focus the tasks on application and operation issues. Primary among inspection requirements for these doublers is the identification of disbonds, between the composite laminate and aluminum parent material, and delaminations in the composite laminate. Surveillance of cracks or corrosion in the parent aluminum material beneath the doubler is also a concern. No single nondestructive inspection (NDI) method can inspect for every flaw type, therefore it is important to be aware of available NDI techniques and to properly address their capabilities and limitations. A series of NDI tests were conducted on laboratory test structures and on full-scale aircraft fuselage sections. Specific challenges, unique to bonded composite doubler applications, were highlighted. An array of conventional and advanced NDI techniques were evaluated. Flaw detection sensitivity studies were conducted on applicable eddy current, ultrasonic, X-ray and thermography based devices. The application of these NDI techniques to composite doublers and the results from test specimens, which were loaded to provide a changing flaw profile, are presented in this report. It was found that a team of these techniques can identify flaws in composite doubler installations well before they reach critical size.

Roach, D.; Walkington, P.

1998-05-01T23:59:59.000Z

416

Endovascular Stent-Graft Repair as a Late Secondary Procedure After Previous Aortic Grafts  

SciTech Connect

Thoracic and abdominal aortic endovascular procedures as alternatives to aortic reoperations were studied in three different cases. An anastomotic aneurysm after previous thoracic aortic graft for coarctation, a second-stage elephant trunk repair (descending thoracic aortic aneurysm), and a secondary aneurysm proximal to a previous abdominal aortic graft were successfully treated with endovascular stent-grafts. During the follow-up period no lethal events or major aortic or graft-related complications were observed, except a type II endoleak in the anastomotic aortic aneurysm case. An endovascular stent-graft can be safely deployed into a previously implanted vascular graft, avoiding repeat surgery.

Matsagas, Miltiadis I. [School of Medicine, University of Ioannina, Department of Surgery - Vascular Surgery Unit (Greece)], E-mail: mimats@cc.uoi.gr; Anagnostopoulos, Constantine E. [School of Medicine, University of Ioannina, Department of Cardiothoracic Surgery (Greece); Papakostas, John C. [School of Medicine, University of Ioannina, Department of Surgery - Vascular Surgery Unit (Greece); DeRose, Joseph J. [St. Luke's-Roosevelt Hospital, Columbia University, Department of Cardiothoracic Surgery (United States); Siminelakis, Stavros [School of Medicine, University of Ioannina, Department of Cardiothoracic Surgery (Greece); Katsouras, Christos S. [School of Medicine, University of Ioannina, Department of Cardiology (Greece); Toumpoulis, Ioannis K.; Drossos, George E. [School of Medicine, University of Ioannina, Department of Cardiothoracic Surgery (Greece); Michalis, Lampros K. [School of Medicine, University of Ioannina, Department of Cardiology (Greece)

2006-08-15T23:59:59.000Z

417

Composite wrap approved for U.S. gas-pipeline repairs  

SciTech Connect

The US agency that oversees pipeline safety has taken the unusual step of waiving certain natural-gas pipeline maintenance regulations and permitted a group of gas-pipeline operators to perform repairs with a patented composite wrap formerly used only on liquids lines. The waivers ar subject to conditions and to future performance evaluations. The wrap is made of polyester resin reinforced by glass filament. On installation, it is tightly wound and adhesively bonded to damaged pipe. The paper describes the 2 waivers, the development of this new technology, savings, and training required by the Dept. of Transportation.

True, W.R.

1995-10-09T23:59:59.000Z

418

Applied Process Engineering Laboratory | Open Energy Information  

Open Energy Info (EERE)

Applied Process Engineering Laboratory Applied Process Engineering Laboratory Name Applied Process Engineering Laboratory Address 350 Hills Street, Suite #101 Place Richland, Washington Zip 99354 Region Pacific Northwest Area Coordinates 46.3389754°, -119.2716263° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":46.3389754,"lon":-119.2716263,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

419

Modeling International Relationships in Applied General Equilibrium  

Open Energy Info (EERE)

Modeling International Relationships in Applied General Equilibrium Modeling International Relationships in Applied General Equilibrium (MIRAGE) Jump to: navigation, search LEDSGP green logo.png FIND MORE DIA TOOLS This tool is part of the Development Impacts Assessment (DIA) Toolkit from the LEDS Global Partnership. Tool Summary LAUNCH TOOL Name: Modeling International Relationships in Applied General Equilibrium (MIRAGE) Agency/Company /Organization: International Food Policy Research Institute, Centre d'Etudes Prospectives et d'Informations Internationales (CEPII) Focus Area: Economic Development Topics: Co-benefits assessment, - Macroeconomic Resource Type: Software/modeling tools User Interface: Desktop Application Complexity/Ease of Use: Moderate Website: www.ifpri.org/book-5076/ourwork/program/mirage-model RelatedTo: Global Trade Analysis Project (GTAP) Data Base

420

How to Apply | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

How to Apply How to Apply How to Apply Awards are made through a formal process that has changed dramatically since 2011. So let us walk you through it step by step. "Innovation pays." - John Kao, Innovation Nation Submit a Letter of Intent On October 28, 2013, the U.S. Department of Energy (DOE) announced on the DOE SBIR website a preview version of the technical topics for which it will later accept funding applications. These topics will be found on the DOE's Funding Opportunity Announcements page. The EE SBIR page lists those topics that are cleantech (specific to EERE). We also recommend that you sign up for the EE-SBIR and DOE-SBIR mailing lists. The EE SBIR mailing list signup is at https://public.govdelivery.com/accounts/USEERE/subscriber/new?topic_id=USEERE_442.

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Applied Field Research Initiative Attenuation Based Remedies  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

PA00133 - March 2011 PA00133 - March 2011 Applied Field Research Initiative Attenuation Based Remedies in the Subsurface Located at the Savannah River Site in Aiken, South Carolina, the Attenuation-Based Remedies in the Subsurface Applied Field Research Initiative (ABRS AFRI) was established to develop the tools, approaches and technologies that will be required to address the technical challenges associated characteriza- tion, remediation and long-term monitoring of recalcitrant compounds in the subsurface at Department of Energy (DOE) Environmental Management (EM) sites. The ABRS AFRI site provides a unique setting for researchers in both applied and basic science fields. A wealth of subsurface data is available to support research activities and remedial decision making.

422

Applied Ventures LLC | Open Energy Information  

Open Energy Info (EERE)

Applied Ventures LLC Applied Ventures LLC Name Applied Ventures LLC Address 3050 Bowers Avenue Place Santa Clara, California Zip 95054 Region Southern CA Area Product Venture capital. Number of employees 1-10 Phone number (408) 727-5555 Website http://www.appliedventures.com Coordinates 37.37751°, -121.978721° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.37751,"lon":-121.978721,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

423

Meta-analysis in applied ecology  

Science Journals Connector (OSTI)

...varied with time, not space, suggesting that local...across species, sites, space and time. Applied ecologists...August 2009). An initial library of more than 500 analyses...pointers from medicine and public health. Conserv. Biol...effects across species, space and time, but exploring...

2010-01-01T23:59:59.000Z

424

APPLIED MATHEMATICS & COMPUTATIONAL SCI. (AS) {AMCS}  

E-Print Network (OSTI)

APPLIED MATHEMATICS & COMPUTATIONAL SCI. (AS) {AMCS} 510. (MATH410) Complex Analysis. 520. (MATH420. (MATH432) Game Theory. 567. (BE 567) Mathematical and Computational Modeling of Biological Systems. (M) Prerequisite(s): BE 324 and BE 350. This is an introductory course in mathematical biology. The emphasis

Carpick, Robert W.

425

Uniform insulation applied-B ion diode  

DOE Patents (OSTI)

An applied-B field extraction ion diode has uniform insulation over an anode surface for increased efficiency. When the uniform insulation is accomplished with anode coils, and a charge-exchange foil is properly placed, the ions may be focused at a point on the z axis.

Seidel, David B. (Albuquerque, NM); Slutz, Stephen A. (Albuquerque, NM)

1988-01-01T23:59:59.000Z

426

Applying Knowledge Management techniques for building corporate  

E-Print Network (OSTI)

Applying Knowledge Management techniques for building corporate memories Ian Watson AI-CBR Computer-based reasoning and knowledge management... www.ai-cbr.org ...coincidentally I've just written a book about this... ...plug the book!!! www.ai-cbr.org Outline · Talk about ­ Knowledge ­ Knowledge management ­ Why CBR

Watson, Ian

427

Applying Quantitative Marketing Techniques to the Internet  

E-Print Network (OSTI)

. Blattberg and Deighton [1991] laid out a good framework for Internet marketing in their articleApplying Quantitative Marketing Techniques to the Internet by Alan L. Montgomery Carnegie Mellon with clickstream data. I illustrate these four modeling techniques and discuss their potential for solving Internet

Faloutsos, Christos

428

Faculty of Engineering Bachelor of Applied Science  

E-Print Network (OSTI)

and Environmental Engineering; Electrical Engineering; Industrial Engineering and Mechanical, Automotive & MaterialsFaculty of Engineering Bachelor of Applied Science in Engineering The demands on professional engineers around the world are increasing in terms of what they must address: our society must confront

429

Applying Global Optimization in Structural Engineering  

E-Print Network (OSTI)

structure Dynamic loading Challenges "Dwarfing visitors, the 70-foot-tall Corliss steam engine powered steam engine in the world. Of engines like the Corliss, William Dean Howells wrote, 'In these thingsApplying Global Optimization in Structural Engineering Dr. George F. Corliss Electrical

430

NONLOCAL COMPUTATIONAL METHODS APPLIED TO COMPOSITE STRUCTURES  

E-Print Network (OSTI)

to model the degradation of organic or ceramic matrix composites structures (OMC or CMC) even under simple description of heterogeneous materia ls like organic or ceramic matrix composites. New sophisticatedNONLOCAL COMPUTATIONAL METHODS APPLIED TO COMPOSITE STRUCTURES N. GERMAIN1, F. FEYEL1 and J. BESSON

Boyer, Edmond

431

Building on a Base: Applying Physics Education  

E-Print Network (OSTI)

Building on a Base: Applying Physics Education Research to Physics Teaching S.J. Pollock CU Boulder Concept Inventory (FCI) R. Hake, "...A six-thousand-student survey..." AJP 66, 64-74 (`98). = post. Pre R. App. Pre R. Care. Pre Math Pre Effort Pre Skept. Pre Overall Post Indep. Post Coher. Post Conc

Colorado at Boulder, University of

432

APPLYING THE ZACHMAN FRAMEWORK DIMENSIONS TO SUPPORT  

E-Print Network (OSTI)

APPLYING THE ZACHMAN FRAMEWORK DIMENSIONS TO SUPPORT BUSINESS PROCESS MODELING Pedro Sousa123.caetano, jose.tribolet}@inov.pt Business process models assist business and information technology managers with disparate blueprints for the same process and no formal procedures to sort out their relevance. In fact

433

Does Bertrand's rule apply to macronutrients?  

Science Journals Connector (OSTI)

...gastrointestinal system. In Handbook of physiology. Section 13 comparative...Christensen2001Optimal diet theory: when does it work, and when and why does it fail?. Anim. Behav. 61...Nutr. Soc. 60, 145-156. Does Bertrand's rule apply to macronutrients...

2005-01-01T23:59:59.000Z

434

Steam turbine maintenance and repair technology: Reducing planned-outage costs  

SciTech Connect

The North American Electric Reliability Council (NAERC) reported that the average loss of equivalent availability per outage for a major fossil turbine overhaul is 323,000 MW-HR. The Electric Power Research Institute (EPRI) Generation and Storage Division, is in the first phase of a major research project to reduce the duration and/or frequency of steam turbine maintenance outages. This project consists of an assessment of the current state-of-the-art turbine maintenance and repair techniques and technologies. It is based on a review of current turbine maintenance practices of the US, European, Japanese, and Australian utility industries. Emphasized are maintenance and repair activities that have the most significant impact on outage duration or frequency. Twenty-six key turbine maintenance activities and the current best techniques were identified for use by utility maintenance personnel. Overall outage durations could be reduced if the duration of these activities were shortened or if they were performed more effectively. Recommended projects for development of advanced steam turbine maintenance technology were identified. 29 refs., 46 figs., 9 tabs.

Grace, H.P.; McClintock, M. (General Physics Corp., Columbia, MD (USA)); Lamping, G. (Southwest Research Inst., San Antonio, TX (USA))

1990-04-01T23:59:59.000Z

435

Spatial variability-based corrosion risk assessment and strategy of repair and maintenance for RC structures  

Science Journals Connector (OSTI)

A corrosion risk assessment model (CRAM) of reinforced concrete structures subjected to marine environment is presented. The spatial variability of parameters, which are decisive for the durability performance, is modelled probabilistically in terms of sample statistics, which may be assessed by testing of existing structures. The result of the chloride profile test is suggested to update the input model parameters for future structural condition prediction. The requirements to the service life performance are formulated in terms of the probability that the structure will be in a certain condition class after a given service time. Further, it is demonstrated how optimal strategies for repair and maintenance of concrete structure subject to chloride ingress can be determined on the basis of corrosion risk classes. The present method to plan optimal repair strategy is illustrated by an assessment case. For structures with large concrete surface exposed to chloride-laden environment, both spatial and temporal characteristics of deterioration are suggested to consider in condition assessment based on field inspection.

Xiao-Zhou Wang; Wei-Liang Jin

2009-01-01T23:59:59.000Z

436

Dofasco`s No. 4 blast furnace hearth breakout, repair and rescue  

SciTech Connect

On May 5, 1994, after producing 9.5 million metric tons of iron, Dofasco`s No. 4 Blast Furnace experienced a hearth breakout 250 millimeters below the west taphole. The hot metal spill caused a fire resulting in severe damage and 33 days of lost production. During a 26-day period, electrical wiring, water drainage systems and both tapholes were repaired. Recovery from an unprepared furnace stop of this length, with the deadman depleted is difficult. To aid with the rescue Hoogovens-designed oxygen/fuel lances were commissioned. The furnace recovery began with a lance in each taphole and all tuyeres plugged. Six days after startup the furnace was casting into torpedo cars, and after nine days operation had returned to normal. This incident prompted Dofasco to expand the hearth monitoring system to detect and prevent similar occurrences. During the repair, 203 new thermocouples were installed in the hearth, concentrating on the tapholes and elephant foot areas. These thermocouples were installed at various depths and locations to allow heat flux calculations. This hearth monitoring system has already identified other problem areas and provided valuable information about hearth drainage patterns. This information has allowed them to develop control strategies to manage localized problem areas.

Donaldson, R.J.; Fischer, A.J.; Sharp, R.M.; Stothart, D.W. [Dofasco Inc., Hamilton, Ontario (Canada)

1995-12-01T23:59:59.000Z

437

Roadmap: Technical and Applied Studies -Computer Technology Networking -Bachelor of Technical and Applied Studies  

E-Print Network (OSTI)

Roadmap: Technical and Applied Studies - Computer Technology Networking - Bachelor of Technical-May-14/JSK This roadmap is a recommended semester-by-semester plan of study for this major. However or individualized specialization selected in consultation with an advisor. #12;Roadmap: Technical and Applied

Khan, Javed I.

438

B.S. Applied Physics Program B.S. in Applied Physics  

E-Print Network (OSTI)

B.S. Applied Physics Program B.S. in Applied Physics Department(s) Physics and Astronomy College and magnetism 3. understanding of thermodynamics 4. understanding of modern physics 5. ability to perform modern laboratory experiments 6. ability to perform an independent physics research project 7. ability

Hemmers, Oliver

439

EFFECT OF THE MODEL CORRELATING STRUCTURAL DAMAGE TO REPAIRING COST ON LIFE CYCLE ECONOMIC LOSS ESTIMATION OF BUILDING STRUCTURES IN HIGH SEISMIC ZONE  

E-Print Network (OSTI)

correlating the damage to repairing cost on the life cycle loss using a simple model. Buildings are modeledEFFECT OF THE MODEL CORRELATING STRUCTURAL DAMAGE TO REPAIRING COST ON LIFE CYCLE ECONOMIC LOSS ESTIMATION OF BUILDING STRUCTURES IN HIGH SEISMIC ZONE Noriyuki TAKAHASHI, Hitoshi SHIOHARA, and Shunsuke

Shiohara, Hitoshi

440

[Studies of the repair of radiation-induced genetic damage in Drosophila]. Annual progress report, February 1, 1993--November 1, 1994  

SciTech Connect

This research focuses on two repair deficient mutations in Drosophila melanogaster, namely mei-9, mei-41. In addition, the authors propose to extend this study to include the mus-312 mutation. They expect these studies to provide substantial insights into both the molecular mechanisms of DNA repair in Drosophila and the role these genes play in normal biological processes.

Hawley, R.S.

1998-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

High Specificity of Quantitative Excision Repair Cross-Complementing 1 Messenger RNA Expression for Prediction of Minor Histopathological Response to Neoadjuvant Radiochemotherapy in Esophageal Cancer  

Science Journals Connector (OSTI)

...analysis of damage recognition process in nucleotide excision repair. J Biol Chem, 278: 7476-85, 2003. 10 Houtsmuller AB, Rademakers S, Nigg AL, et al Action of DNA repair endonuclease ERCC1/XPF in living cells. Science (Wash DC), 284: 958-61...

Ute Warnecke-Eberz; Ralf Metzger; Futoshi Miyazono; Stephan E. Baldus; Susanne Neiss; Jan Brabender; Hartmut Schaefer; Walter Doerfler; Elfriede Bollschweiler; Hans P. Dienes; Rolf P. Mueller; Peter V. Danenberg; Arnulf H. Hoelscher; Paul M. Schneider

2004-06-01T23:59:59.000Z

442

The RecQ4 Orthologue Hrq1 Is Critical for DNA Interstrand Cross-Link Repair and Genome Stability in Fission Yeast  

Science Journals Connector (OSTI)

...Cross-Link Repair and Genome Stability in Fission Yeast Lynda...substrates, including bubbles but not blunt duplexes...mediators of genome stability include the RecQ family...cross-link repair and genome stability in fission yeast...substrates, including bubbles but not blunt duplexes...

Lynda M. Groocock; John Prudden; J. Jefferson P. Perry; Michael N. Boddy

2011-11-07T23:59:59.000Z

443

Photoaffinity Labeling of Mouse Fibroblast Enzymes by a Base Excision Repair Intermediate: New Evidence on the Role of PARP-1 in DNA Repair  

SciTech Connect

To examine mammalian base excision repair (BER) enzymes interacting with DNA intermediates formed during BER, we used a novel photoaffinity labeling probe and mouse embryonic fibroblast (MEF) crude extract. The probe was formed in situ, using an end-labeled oligonucleotide containing a synthetic abasic site; this site was incised by AP endonuclease creating a nick with 3' hydroxyl and 5' reduced sugar phosphate groups at the margins, and then a dNMP carrying a photoreactive adduct was introduced at the 3' hydroxyl group. With near UV-light exposure (312nm) of the extract-probe mixture, only six proteins were strongly labeled, including poly (ADP-ribose) polymerase (PARP-1) and the well-known BER participants flap endonuclease (FEN-1), DNA polymerase b (b-pol), and AP endonuclease (APE). The amount of probe crosslinked to PARP-1 was greater than that crosslinked to the other proteins. The specificity of PARP-1 labeling was examined by competition experiments involving various oligonucleotide competitors; competition of labeling by the probe was much greater for the BER intermediates tested than for normal double-stranded DNA. The specificity of PARP-1 labeling also was examined using DNA probes with alternate structures; PARP-1 labeling was stronger with a DNA oligomer representing a BER intermediate than with a molecule representing a nick in double-stranded DNA. These results identifying interaction of PARP-1 with a BER intermediate are discussed in light of PARP-1's role in mammalian BER.

Lavrik, Olga I.(National Institute of Environmental Health Sciences) [National Institute of Environmental Health Sciences; Prasad, Rajendra (National Institute of Environmental Health Sciences) [National Institute of Environmental Health Sciences; Sobol, Robert W.(National Institute of Environmental Health Sciences) [National Institute of Environmental Health Sciences; Horton, Julie K.(National Institute of Environmental Health Sciences) [National Institute of Environmental Health Sciences; Ackerman, Eric J.(BATTELLE (PACIFIC NW LAB)) [BATTELLE (PACIFIC NW LAB); Wilson, Samuel H.(National Institute of Environmental Health Sciences) [National Institute of Environmental Health Sciences

2001-07-06T23:59:59.000Z

444

E-Print Network 3.0 - aneurysm repair evar Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Source: Papaharilaou, Yannis - Institute of Applied and Computational Mathematics, Foundation of Research and Technology, Hellas Collection: Computer Technologies and Information...

445

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

51 - 9660 of 28,560 results. 51 - 9660 of 28,560 results. Download CX-006637: Categorical Exclusion Determination Repair Storm Water Drainage Outside the T-Area Cap CX(s) Applied: B1.3 Date: 08/10/2011 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-006637-categorical-exclusion-determination Download CX-006636: Categorical Exclusion Determination Removal and Disposition of Mini Melter in 786-A CX(s) Applied: B1.23 Date: 08/08/2011 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-006636-categorical-exclusion-determination Download CX-006633: Categorical Exclusion Determination Install a Portable Generator to Supply Electrical Power to the 241-74F Switchgear Bus

446

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

51 - 6860 of 28,905 results. 51 - 6860 of 28,905 results. Download CX-006609: Categorical Exclusion Determination EM-31 Alternative Chemical Cleaning (ACC) Program CX(s) Applied: B3.6 Date: 05/24/2010 Location(s): Aiken, South Carolina Office(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-006609-categorical-exclusion-determination Download CX-002534: Categorical Exclusion Determination Repair 4-Inch Domestic Water Header, Z-Area CX(s) Applied: B1.3 Date: 05/12/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-002534-categorical-exclusion-determination Download CX-002537: Categorical Exclusion Determination Measurement of Distribution Coefficients for Z-Area Industrial Solid Waste

447

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81 - 4790 of 26,777 results. 81 - 4790 of 26,777 results. Download CX-001134: Categorical Exclusion Determination Repair Water Leak in L-Area Valve 075 CX(s) Applied: B1.3 Date: 03/04/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-001134-categorical-exclusion-determination Download CX-001018: Categorical Exclusion Determination Internal Short Circuits in Lithium-Ion Cells for Plug-In Electric Vehicle (PHEV) CX(s) Applied: B3.6 Date: 03/04/2010 Location(s): Cambridge, Massachusetts Office(s): Energy Efficiency and Renewable Energy, National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-001018-categorical-exclusion-determination Download CX-005147: Categorical Exclusion Determination

448

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

21 - 21830 of 26,764 results. 21 - 21830 of 26,764 results. Download CX-007509: Categorical Exclusion Determination Record of Categorical Exclusion for Use of RW Surge Line to Big Hill Anhydrite Pond for Raw Water Intake Structure Recycle CX(s) Applied: B1.3 Date: 11/28/2011 Location(s): Texas Offices(s): Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-007509-categorical-exclusion-determination Download CX-007510: Categorical Exclusion Determination Record of Categorical Exclusion for Tear Down, Inspect and Repair Bayou Choctaw Brine Filters at BDW Pad 1 CX(s) Applied: B1.3 Date: 11/29/2011 Location(s): Louisiana Offices(s): Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-007510-categorical-exclusion-determination Download CX-007511: Categorical Exclusion Determination

449

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81 - 5790 of 8,172 results. 81 - 5790 of 8,172 results. Download CX-004105: Categorical Exclusion Determination High Resolution Three-Dimensional Laser Imaging for Inspection, Maintenance, Repair and Operations CX(s) Applied: B3.6 Date: 09/30/2010 Location(s): Houston, Texas Office(s): Fossil Energy, National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-004105-categorical-exclusion-determination Download CX-004106: Categorical Exclusion Determination Green Oil: Carbon Dioxide Enhanced Oil Recovery for America?s Small Oil Producers CX(s) Applied: A9 Date: 09/30/2010 Location(s): Socorro, New Mexico Office(s): Fossil Energy, National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-004106-categorical-exclusion-determination Download CX-004108: Categorical Exclusion Determination

450

Categorical Exclusion Determinations: Arizona | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Arizona Arizona Categorical Exclusion Determinations: Arizona Location Categorical Exclusion Determinations issued for actions in Arizona. DOCUMENTS AVAILABLE FOR DOWNLOAD September 13, 2013 CX-010988: Categorical Exclusion Determination High Temperature DC-Bus Capacitors Cost Reduction and Performance Improvements CX(s) Applied: B3.6, B5.15 Date: 09/13/2013 Location(s): Arizona Offices(s): National Energy Technology Laboratory August 22, 2013 CX-010882: Categorical Exclusion Determination Liberty-Parker Dam #2 230-Kilovolt Transmission Line, Optical Power Ground Wire Repair CX(s) Applied: B4.7 Date: 08/22/2013 Location(s): Arizona Offices(s): Western Area Power Administration-Desert Southwest Region August 12, 2013 CX-010883: Categorical Exclusion Determination PHX-LOB and LIB-LOB 230-Kilovolt Double-Circuit- Replace Insulators at

451

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

41 - 25750 of 31,917 results. 41 - 25750 of 31,917 results. Download CX-001369: Categorical Exclusion Determination Repair Firewater Line in B-Area East Side (Road C-2) near Post Indicator Valve 2118 CX(s) Applied: B1.3 Date: 03/16/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-001369-categorical-exclusion-determination Download CX-001371: Categorical Exclusion Determination Synthetic Concentrators CX(s) Applied: B3.6 Date: 03/16/2010 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-001371-categorical-exclusion-determination Download CX-001182: Categorical Exclusion Determination Access Road Improvement Project for Structure 12/1 of the Snoking Tap to

452

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

51 - 27360 of 28,904 results. 51 - 27360 of 28,904 results. Download CX-007673: Categorical Exclusion Determination Edible Oil Deployment for Enhanced Chlorinated Volatile Organic Compounds Attenuation at the M Area Abandoned Process Sewer Line CX(s) Applied: B3.1 Date: 10/25/2011 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-007673-categorical-exclusion-determination Download CX-007675: Categorical Exclusion Determination Repair of Fire Water Line Near 254-13F CX(s) Applied: B1.3 Date: 10/20/2011 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-007675-categorical-exclusion-determination Article DOE-Supported Education and Training Programs Help Crow Tribe Promote Energy Independence and Education

453

Categorical Exclusion (CX) Determinations By Date | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

28, 2011 28, 2011 CX-007772: Categorical Exclusion Determination Idaho National Laboratory Asphalt Repair Project - North Wind Services, LLC CX(s) Applied: B1.3 Date: 11/28/2011 Location(s): Idaho Offices(s): Nuclear Energy, Idaho Operations Office November 28, 2011 CX-007771: Categorical Exclusion Determination Nuclear Energy University Programs Minor Reactor Upgrade Request for Enhancement of Safety and Operational Monitoring Systems and Research Capabilities of the Ohio State University Nuclear Reactor Laboratory CX(s) Applied: B2.2 Date: 11/28/2011 Location(s): Ohio Offices(s): Nuclear Energy, Idaho Operations Office November 28, 2011 CX-007770: Categorical Exclusion Determination Meeting Nuclear Uniform Curriculum Program Requirements with Equipment Investments - Lakeshore Technical College

454

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81 - 13490 of 26,764 results. 81 - 13490 of 26,764 results. Download CX-009353: Categorical Exclusion Determination The Sustainability Workshop (Energy Regional Innovation Cluster) CX(s) Applied: A9 Date: 09/20/2012 Location(s): Pennsylvania Offices(s): National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-009353-categorical-exclusion-determination Download CX-009354: Categorical Exclusion Determination High Resolution 3D Laser Imaging for Inspection, Maintenance, Repair and Operations - Phase II CX(s) Applied: A9, A11, B3.6 Date: 09/20/2012 Location(s): Colorado Offices(s): National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-009354-categorical-exclusion-determination Download CX-009355: Categorical Exclusion Determination Building 922 Ice Melt/Heat Trace Project

455

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

41 - 11350 of 28,905 results. 41 - 11350 of 28,905 results. Download CX-005422: Categorical Exclusion Determination La Pine Chiloquin and Brasada Harney Number 1 Transmission Line Right-of-Ways CX(s) Applied: B1.3 Date: 03/15/2011 Location(s): Klamath County, Oregon Office(s): Bonneville Power Administration http://energy.gov/nepa/downloads/cx-005422-categorical-exclusion-determination Download CX-005847: Categorical Exclusion Determination Rocky Reach - Maple Valley Access Road Repair CX(s) Applied: B1.3 Date: 05/05/2011 Location(s): King County, Washington Office(s): Bonneville Power Administration http://energy.gov/nepa/downloads/cx-005847-categorical-exclusion-determination Download Audit Report: OAS-L-03-19 Audit of Recurring Acquisitions at the Chicago Operations Office http://energy.gov/ig/downloads/audit-report-oas-l-03-19

456

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81 - 9890 of 28,560 results. 81 - 9890 of 28,560 results. Download CX-005531: Categorical Exclusion Determination Repair a Leaking Duct Flange in F/H Lab CX(s) Applied: B1.3 Date: 01/26/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-005531-categorical-exclusion-determination Download CX-005533: Categorical Exclusion Determination K-Area Entrance Roadway Expansion CX(s) Applied: B1.13 Date: 01/26/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-005533-categorical-exclusion-determination Download CX-005536: Categorical Exclusion Determination Rework Fire-rated Penetration Seal Per F-DCF-H-00591HB-Line Room 602A Floor

457

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

31 - 8240 of 26,764 results. 31 - 8240 of 26,764 results. Download CX-003594: Categorical Exclusion Determination Replace Bayou Choctaw Timber Pile Pipe Supports CX(s) Applied: B1.3 Date: 08/24/2010 Location(s): Bayou Choctaw, Louisiana Office(s): Fossil Energy, Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-003594-categorical-exclusion-determination Download CX-003596: Categorical Exclusion Determination Bayou Choctaw Site Building Upgrades, Phases II and III CX(s) Applied: B1.3 Date: 08/24/2010 Location(s): Bayou Choctaw, Louisiana Office(s): Fossil Energy, Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-003596-categorical-exclusion-determination Download CX-002830: Categorical Exclusion Determination Repairs to Men?s Bathroom in West Hackberry Building 302

458

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

401 - 24410 of 26,764 results. 401 - 24410 of 26,764 results. Download CX-009639: Categorical Exclusion Determination Characterization, Investigation, and Environmental Monitoring Activities CX(s) Applied: B3.1 Date: 11/19/2012 Location(s): Tennessee, California, California, Virginia Offices(s): Oak Ridge Office http://energy.gov/nepa/downloads/cx-009639-categorical-exclusion-determination Download CX-009615: Categorical Exclusion Determination Y646 (Y189), Renovation of E-Wing Ventilation, Building 773-A CX(s) Applied: B2.1 Date: 11/09/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-009615-categorical-exclusion-determination Download CX-009510: Categorical Exclusion Determination Strategic Petroleum Reserve Emergency Pipeline and Piping Repair, 2013-2017

459

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

11 - 8220 of 26,764 results. 11 - 8220 of 26,764 results. Download CX-000870: Categorical Exclusion Determination West Hackberry Air Conditioning/Heating Repairs CX(s) Applied: B1.3 Date: 02/05/2010 Location(s): West Hackberry, Louisiana Office(s): Fossil Energy, Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-000870-categorical-exclusion-determination Download CX-005895: Categorical Exclusion Determination Relocation of Bayou Choctaw Entry Portal Building CX(s) Applied: B1.3 Date: 05/05/2011 Location(s): Louisiana Office(s): Fossil Energy, Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-005895-categorical-exclusion-determination Download CX-005897: Categorical Exclusion Determination Bryan Mound Upgrade Wood to Steel Lighting Poles

460

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

51 - 14360 of 29,416 results. 51 - 14360 of 29,416 results. Download CX-010848: Categorical Exclusion Determination 300 square feet of Modified Bitumen Roof Repair CX(s) Applied: B1.3 Date: 07/23/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-010848-categorical-exclusion-determination Download CX-010849: Categorical Exclusion Determination Temporary Removal of the Tank 12 Purge Exhaust Reheater via HTF-TMC-13-028 CX(s) Applied: B1.3 Date: 07/23/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office http://energy.gov/nepa/downloads/cx-010849-categorical-exclusion-determination Download CX-010850: Categorical Exclusion Determination Install Well Pump into the F-Tank Farm Catch Tank FL-241901-WTS-TK-1

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

31 - 18240 of 26,764 results. 31 - 18240 of 26,764 results. Download CX-003662: Categorical Exclusion Determination Hygiene Substation Access Road Repairs CX(s) Applied: B1.3, B4.6 Date: 08/30/2010 Location(s): Boulder County, Colorado Office(s): Western Area Power Administration-Rocky Mountain Region http://energy.gov/nepa/downloads/cx-003662-categorical-exclusion-determination Download CX-003507: Categorical Exclusion Determination State Energy Program American Recovery and Reinvestment Act: Solar Power Incorporated Photovoltaic Panel Manufacturing Facility CX(s) Applied: B1.31, B5.1 Date: 08/27/2010 Location(s): McClellan, California Office(s): Energy Efficiency and Renewable Energy, Golden Field Office http://energy.gov/nepa/downloads/cx-003507-categorical-exclusion-determination Download CX-003508: Categorical Exclusion Determination

462

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

31 - 21440 of 31,917 results. 31 - 21440 of 31,917 results. Download CX-008938: Categorical Exclusion Determination An Advanced Joint Inversion System for Carbon Dioxide Storage Modeling with Large Data Sets for Characterization CX(s) Applied: A1, A9 Date: 08/17/2012 Location(s): California Offices(s): National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-008938-categorical-exclusion-determination Download CX-008942: Categorical Exclusion Determination Site-Wide Sidewalk Improvements and Seal and Repair Pavement CX(s) Applied: B1.3 Date: 08/17/2012 Location(s): West Virginia Offices(s): National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-008942-categorical-exclusion-determination Download CX-008943: Categorical Exclusion Determination B-33 Facility & Heating, Ventilation, and Air Conditioning Renovations

463

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81 - 12390 of 28,905 results. 81 - 12390 of 28,905 results. Download CX-007772: Categorical Exclusion Determination Idaho National Laboratory Asphalt Repair Project - North Wind Services, LLC CX(s) Applied: B1.3 Date: 11/28/2011 Location(s): Idaho Offices(s): Nuclear Energy, Idaho Operations Office http://energy.gov/nepa/downloads/cx-007772-categorical-exclusion-determination Download CX-009522: Categorical Exclusion Determination Nevada-City-North Las Vegas CX(s) Applied: A1, A9, B1.32, B2.5, B5.1 Date: 11/15/2012 Location(s): Nevada Offices(s): Energy Efficiency and Renewable Energy http://energy.gov/nepa/downloads/cx-009522-categorical-exclusion-determination Download TEC Working Group Topic Groups Tribal Conference Call Summaries http://energy.gov/em/downloads/tec-working-group-topic-groups-tribal-conference-call-summaries

464

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

01 - 17910 of 26,764 results. 01 - 17910 of 26,764 results. Download CX-006140: Categorical Exclusion Determination Revised Market Title for Energy Efficiency Program for Municipalities, Schools, Hospitals, Public Colleges CX(s) Applied: A9, A11, B5.1 Date: 06/14/2011 Location(s): New York Office(s): Energy Efficiency and Renewable Energy, National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-006140-categorical-exclusion-determination Download CX-001125: Categorical Exclusion Determination Blading of Washed Out Access Road and Repairing the Washed Out Area Inside the Substation Fence CX(s) Applied: B1.3 Date: 11/12/2009 Location(s): Mohave County, Arizona Office(s): Western Area Power Administration-Desert Southwest Region http://energy.gov/nepa/downloads/cx-001125-categorical-exclusion-determination

465

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

31 - 9340 of 28,560 results. 31 - 9340 of 28,560 results. Download CX-007507: Categorical Exclusion Determination Record of Categorical Exclusion for Inspection and Repair of West Hackberry-SUN 42-inch Crude Oil Pipeline CX(s) Applied: B1.3 Date: 11/28/2011 Location(s): Louisiana Offices(s): Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-007507-categorical-exclusion-determination Download CX-007508: Categorical Exclusion Determination Record of Categorical Exclusion for Rework Bryan Mound Seaway Dock Terminal Bypass Valve MOV-C308 CX(s) Applied: B1.3 Date: 11/16/2011 Location(s): Texas Offices(s): Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-007508-categorical-exclusion-determination Download CX-007509: Categorical Exclusion Determination

466

Categorical Exclusion Determinations: B1.13 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

19, 2011 19, 2011 CX-005684: Categorical Exclusion Determination Construction and Operation of a Cask Processing Enclosure (CPE) at the Transuranic (TRU) Waste Processing Center (TWPC) on the Oak Ridge Reservation, Lenoir City, Tennessee CX(s) Applied: B1.13, B3.1, B6.6 Date: 04/19/2011 Location(s): Lenoir City, Tennessee Office(s): Oak Ridge Office April 19, 2011 CX-006384: Categorical Exclusion Determination Construction and Operation of a Cask Processing Enclosure at the Transuranic Waste Processing Center on the Oak Ridge Reservation, Lenoir City, Tennessee CX(s) Applied: B1.13, B3.1, B6.6 Date: 04/19/2011 Location(s): Lenoir City, Tennessee Office(s): Environmental Management, Oak Ridge Office March 23, 2011 CX-005855: Categorical Exclusion Determination Sidewalks Repair at 704-23K and 701-12K

467

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

91 - 10600 of 31,917 results. 91 - 10600 of 31,917 results. Download CX-004470: Categorical Exclusion Determination Relocation of Laboratory on Morgantown Site from B25/102 to B4/112 CX(s) Applied: B3.6 Date: 11/18/2010 Location(s): Morgantown, West Virginia Office(s): Fossil Energy, National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-004470-categorical-exclusion-determination Download CX-004401: Categorical Exclusion Determination The Use of Scrap Tires for Oil Well Stimulation CX(s) Applied: B3.6 Date: 11/08/2010 Location(s): Waynesburg, Pennsylvania Office(s): Fossil Energy, National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-004401-categorical-exclusion-determination Download CX-004400: Categorical Exclusion Determination Repair Brick Support Plates on Connecting Bridges - Building 58

468

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

691 - 25700 of 31,917 results. 691 - 25700 of 31,917 results. Download CX-005799: Categorical Exclusion Determination Repair of Fire Water Line Near 254-13F CX(s) Applied: B1.3 Date: 04/06/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-005799-categorical-exclusion-determination Download CX-005800: Categorical Exclusion Determination Detoxification of Uranium in Soils and Groundwater Using Recycled Concrete CX(s) Applied: B3.6 Date: 04/05/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office http://energy.gov/nepa/downloads/cx-005800-categorical-exclusion-determination Download CX-005801: Categorical Exclusion Determination Polymer Synthesis, Corrosion, and Electrochemical Tests in Lab D-0115

469

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

61 - 4270 of 9,640 results. 61 - 4270 of 9,640 results. Download CX-008911: Categorical Exclusion Determination Pittsburgh B83 Boiler Room Ventilation/Cooling Project CX(s) Applied: B2.1, B2.2, B2.3 Date: 08/29/2012 Location(s): Pennsylvania Offices(s): National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-008911-categorical-exclusion-determination Download CX-008912: Categorical Exclusion Determination An Advanced Joint Inversion System for Carbon Dioxide Storage Modeling with Large Data Sets for Characterization CX(s) Applied: A1, A9 Date: 08/29/2012 Location(s): California Offices(s): National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-008912-categorical-exclusion-determination Download CX-008913: Categorical Exclusion Determination High Resolution 3D Laser Imaging for Inspection, Maintenance, Repair and

470

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

61 - 10570 of 26,764 results. 61 - 10570 of 26,764 results. Download CX-004099: Categorical Exclusion Determination Advanced Energy Efficient Building Technologies for High Performance Hospitals CX(s) Applied: A9 Date: 09/30/2010 Location(s): Eugene, Oregon Office(s): Energy Efficiency and Renewable Energy, National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-004099-categorical-exclusion-determination Download CX-004100: Categorical Exclusion Determination High Resolution Three-Dimensional Laser Imaging for Inspection, Maintenance, Repair and Operations CX(s) Applied: B3.6 Date: 09/30/2010 Location(s): Boulder, Colorado Office(s): Fossil Energy, National Energy Technology Laboratory http://energy.gov/nepa/downloads/cx-004100-categorical-exclusion-determination Download CX-004105: Categorical Exclusion Determination

471

Categorical Exclusion Determinations: Western Area Power  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Desert Southwest Region Desert Southwest Region Categorical Exclusion Determinations: Western Area Power Administration-Desert Southwest Region Categorical Exclusion Determinations issued by Western Area Power Administration-Desert Southwest Region. DOCUMENTS AVAILABLE FOR DOWNLOAD August 22, 2013 CX-010882: Categorical Exclusion Determination Liberty-Parker Dam #2 230-Kilovolt Transmission Line, Optical Power Ground Wire Repair CX(s) Applied: B4.7 Date: 08/22/2013 Location(s): Arizona Offices(s): Western Area Power Administration-Desert Southwest Region August 12, 2013 CX-010883: Categorical Exclusion Determination PHX-LOB and LIB-LOB 230-Kilovolt Double-Circuit- Replace Insulators at Structure No. 28-2 With NCI Type Polymers CX(s) Applied: B1.3 Date: 08/12/2013 Location(s): Arizona Offices(s): Western Area Power Administration-Desert Southwest Region

472

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

41 - 21650 of 26,764 results. 41 - 21650 of 26,764 results. Download CX-009217: Categorical Exclusion Determination Elmwood Dog Kennel Repair (Hurricane Isaac) CX(s) Applied: B1.3 Date: 09/24/2012 Location(s): CX: none Offices(s): Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-009217-categorical-exclusion-determination Download CX-009218: Categorical Exclusion Determination Replace Sparge Piping at Bryan Mound Raw Water Intake Structure CX(s) Applied: B1.3 Date: 09/20/2012 Location(s): Texas Offices(s): Strategic Petroleum Reserve Field Office http://energy.gov/nepa/downloads/cx-009218-categorical-exclusion-determination Article Energy Department, Treasury Announce Availability of $150 Million in Tax Credits for Clean Energy Manufacturers The U.S. Departments of Energy and the Treasury announced the availability

473

Fundamental & Applied Bioenergy | Clean Energy | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Bioenergy Bioenergy SHARE Fundamental and Applied Bioenergy Steven Brown (left) and Shihui Yang have developed a microbial strain with an improved ability to convert wood products to biofuel as part of research within the DOE BioEnergy Science Center.Source: ORNL News article ORNL researchers are investigating the biological mechanisms underlying production of biofuels so that those mechanisms can be improved and used to develop a new generation of efficient bioenergy strategies that will reduce U.S. dependence on foreign oil and help curb carbon emissions. Fundamental and applied bioenergy research at ORNL includes studies conducted within the BioEnergy Science Center and the following research areas: Bioconversion Science and Technology Plant-Microbe Interfaces

474

Apply for Beam Time | Advanced Photon Source  

NLE Websites -- All DOE Office Websites (Extended Search)

Apply for Beam Time Apply for Beam Time NEXT PROPOSAL DEADLINE: March 7, 2014 @ 11:59 PM (Chicago time) Submit Proposal » SEE ALSO: Calendar: deadlines, run & review dates Help Page: frequently asked questions, tips for success, common errors, blank forms, instructions Review Criteria Sectors Directory: check CAT websites for info about managed beam time The Run 2014-2 proposal submission deadline is 11:59 p.m. (Chicago time) March 7, 2014. The system will open to accept proposals beginning December 20, 2013. NEW USERS: to avoid delays and to make the most of your time on site, read Become a User. You must register as a user and receive a badge number before submitting a proposal. About the Beam Time Request Process All beam time at the APS must be requested each cycle through the web-based

475

Title Page Applied and Environmental Microbiology 1  

NLE Websites -- All DOE Office Websites (Extended Search)

Applied and Environmental Microbiology 1 Applied and Environmental Microbiology 1 2 Title Natural Competence in Thermoanaerobacter and Thermoanaerobacterium Species 3 Running Title Thermonanerobacter Natural Competence 4 5 Authors and Affiliations 6 A. Joe Shaw 1,2 , David A. Hogsett 1 , Lee R. Lynd 1,2,3 * 7 1 Mascoma Corporation, Lebanon, NH 03766 8 2 Thayer School of Engineering, Dartmouth College, Hanover, NH 03755 9 3 Department of Biological Sciences, Dartmouth College, Hanover, NH 03755 10 11 Corresponding Author 12 Lee R. Lynd 13 Thayer School of Engineering, Dartmouth College, Hanover, NH 03755 14 Phone: 603.646.2231 15 Email: lee.lynd@dartmouth.edu 16 17 18 19 20 21 22 23 Copyright © 2010, American Society for Microbiology and/or the Listed Authors/Institutions. All Rights Reserved.

476

Slip Line Field Applied To Deep Drawing  

Science Journals Connector (OSTI)

Slip Line Field is a numerical method applied for modelling plane?strain processes. This method has been successfully checked properly for sheet drawing. Flange deformation in deep drawing is considered without change in thickness. A drawing mechanical test has been developed in order to reproduce the flange stresses state in sheet strips with the rolling direction selected. The fundamentals of this test and some experimental results obtained from it have been presented previously in different Congresses. In this work an algorithm based on SLF has been implemented and theoretical results evaluated for different conditions. The algorithm have been applied to a mild DDQ steel and to a DDQ AISI 304 stainless steel. Theoretical and experimental results are compared. A good concordance in them has been found out under some conditions. One of the most important aspects is that it must not be considered tensile material properties but a modified behavior under multiaxial conditions.

V. Miguel; J. Benet; J. Coello; A. Calatayud; A. Martínez

2007-01-01T23:59:59.000Z

477

Apply process integration to waste minimization  

SciTech Connect

This article presents a systematic method for identifying process modifications to minimize waste generation. It is based on the hierarchical decision procedure, which provides a framework for identifying process improvement options and evaluating heat and mass integration opportunities. The article deals specifically with an adaptation of the hierarchical decision approach for use in pollution abatement applications. The article also illustrates the use of the technique by applying it to the fluid catalytic cracking unit at Amoco Oil Co.'s Yorktown, VA, refinery.

Rossiter, A.P.; Spriggs, H.D. (Linnhoff March, Inc., Leesburg, VA (United States)); Klee, H. Jr. (Amoco Corp., Chicago, IL (United States))

1993-01-01T23:59:59.000Z

478

Applying Calibration to Improve Uncertainty Assessment  

E-Print Network (OSTI)

. INTRODUCTION AND BACKGROUND 1.1 Introduction The oil and gas industry is full of uncertainty. In addition to significant subsurface uncertainty and uncertainty in oil and gas prices, there are other risks, e.g., political, that contribute to uncertainty... that is commonly applied in other industries for assessing forecasts and was initially developed to assess weather forecasts (Brier, 1950). Lichtenstein and Fischhoff (1977) summarized the background for the 3 Brier score and its components. The Brier score...

Fondren, Mark Edward

2013-08-02T23:59:59.000Z

479

Fluid Bed Combustion Applied to Industrial Waste  

E-Print Network (OSTI)

of its relatively recent application to coal fired steam production, fluid beds have been uti lized in industry for over 60 years. Beginning in Germany in the twenties for coal gasification, the technology was applied to catalytic cracking of heavy... system cost), use of minimum excess air required, and maintaining the min"imum reactor temperature neces sary to sustain combustion. For superautogenous fuels, where incineration. only is desired, minimum capital cost is achieved by using direct bed...

Mullen, J. F.; Sneyd, R. J.

480

Oxidative DNA damage and its repair in rat spleen following subchronic exposure to aniline  

SciTech Connect

The mechanisms by which aniline exposure elicits splenotoxic response, especially the tumorigenic response, are not well-understood. Splenotoxicity of aniline is associated with iron overload and generation of reactive oxygen species (ROS) which can cause oxidative damage to DNA, proteins and lipids (oxidative stress). 8-Hydroxy-2'-deoxyguanosine (8-OHdG) is one of the most abundant oxidative DNA lesions resulting from ROS, and 8-oxoguanine glycosylase 1 (OGG1), a specific DNA glycosylase/lyase enzyme, plays a key role in the removal of 8-OHdG adducts. This study focused on examining DNA damage (8-OHdG) and repair (OGG1) in the spleen in an experimental condition preceding a tumorigenic response. To achieve that, male Sprague-Dawley rats were subchronically exposed to aniline (0.5 mmol/kg/day via drinking water for 30 days), while controls received drinking water only. Aniline treatment led to a significant increase in splenic oxidative DNA damage, manifested as a 2.8-fold increase in 8-OHdG levels. DNA repair activity, measured as OGG1 base excision repair (BER) activity, increased by {approx} 1.3 fold in the nuclear protein extracts (NE) and {approx} 1.2 fold in the mitochondrial protein extracts (ME) of spleens from aniline-treated rats as compared to the controls. Real-time PCR analysis for OGG1 mRNA expression in the spleen revealed a 2-fold increase in expression in aniline-treated rats than the controls. Likewise, OGG1 protein expression in the NEs of spleens from aniline-treated rats was {approx} 1.5 fold higher, whereas in the MEs it was {approx} 1.3 fold higher than the controls. Aniline treatment also led to stronger immunostaining for both 8-OHdG and OGG1 in the spleens, confined to the red pulp areas. It is thus evident from our studies that aniline-induced oxidative stress is associated with increased oxidative DNA damage. The BER pathway was also activated, but not enough to prevent the accumulation of oxidative DNA damage (8-OHdG). Accumulation of mutagenic oxidative DNA lesions in the spleen following exposure to aniline could play a critical role in the tumorigenic process.

Ma Huaxian; Wang Jianling [Department of Pathology, University of Texas Medical Branch, Galveston, TX 77555 (United States); Abdel-Rahman, Sherif Z. [Department of Preventive Medicine and Community Health, University of Texas Medical Branch, Galveston, TX 77555 (United States); Boor, Paul J. [Department of Pathology, University of Texas Medical Branch, Galveston, TX 77555 (United States); Khan, M. Firoze [Department of Pathology, University of Texas Medical Branch, Galveston, TX 77555 (United States)], E-mail: mfkhan@utmb.edu

2008-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "repairs cxs applied" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Global-to-Local Rule Generation for Self-Assembly and Self-Repair by Robot Swarms  

E-Print Network (OSTI)

Global-to-Local Rule Generation for Self-Assembly and Self-Repair by Robot Swarms Daniel Arbuckle a reactive self-assembly technique intended for use in swarms of simple robots, the other a distributed in the possibility that swarms of general-purpose self-assembling robots might be used to replace many such objects

Southern California, University of

482

Cadmium sulfate and CdTe-quantum dots alter DNA repair in zebrafish (Danio rerio) liver cells  

SciTech Connect

Increasing use of quantum dots (QDs) makes it necessary to evaluate their toxicological impacts on aquatic organisms, since their contamination of surface water is inevitable. This study compares the genotoxic effects of ionic Cd versus CdTe nanocrystals in zebrafish hepatocytes. After 24 h of CdSO{sub 4} or CdTe QD exposure, zebrafish liver (ZFL) cells showed a decreased number of viable cells, an accumulation of Cd, an increased formation of reactive oxygen species (ROS), and an induction of DNA strand breaks. Measured levels of stress defense and DNA repair genes were elevated in both cases. However, removal of bulky DNA adducts by nucleotide excision repair (NER) was inhibited with CdSO{sub 4} but not with CdTe QDs. The adverse effects caused by acute exposure of CdTe QDs might be mediated through differing mechanisms than those resulting from ionic cadmium toxicity, and studying the effects of metallic components may be not enough to explain QD toxicities in aquatic organisms. - Highlights: • Both CdSO{sub 4} and CdTe QDs lead to cell death and Cd accumulation. • Both CdSO{sub 4} and CdTe QDs induce cellular ROS generation and DNA strand breaks. • Both CdSO{sub 4} and CdTe QDs induce the expressions of stress defense and DNA repair genes. • NER repair capacity was inhibited with CdSO{sub 4} but not with CdTe QDs.

Tang, Song; Cai, Qingsong [The Institute of Environmental and Human Health, Texas Tech University, Lubbock, TX 79416 (United States); Chibli, Hicham [Department of Biomedical Engineering, McGill University, Montréal, QC H3A 2B4 (Canada); Allagadda, Vinay [The Institute of Environmental and Human Health, Texas Tech University, Lubbock, TX 79416 (United States); Nadeau, Jay L. [Department of Biomedical Engineering, McGill University, Montréal, QC H3A 2B4 (Canada); Mayer, Gregory D., E-mail: greg.mayer@ttu.edu [The Institute of Environmental and Human Health, Texas Tech University, Lubbock, TX 79416 (United States)

2013-10-15T23:59:59.000Z

483

Activation of the Fanconi Anemia/BRCA Pathway and Recombination Repair in the Cellular Response to Solar Ultraviolet Light  

Science Journals Connector (OSTI)

...in the Cellular Response to Solar Ultraviolet Light Jessica Dunn...School of Medicine, Boston, Massachusetts Recombination repair plays...primary skin cells exposed to solar-simulated light. UV-induced...integrity of their genome, solar UV light plays a pivotal role...

Jessica Dunn; Marisa Potter; Adam Rees; and Thomas M. Rünger

2006-12-01T23:59:59.000Z

484

Arellano, Tatum, Stark, Horvath, Leshchinsky 1 Interim Design Guideline for EPS-Block Geofoam in Slope Stabilization and Repair  

E-Print Network (OSTI)

Arellano, Tatum, Stark, Horvath, Leshchinsky 1 Interim Design Guideline for EPS-Block Geofoam of expanded polystyrene (EPS)-block geofoam3 for slope stabilization and repair based on the National for the use of EPS-block geofoam6 for the function of lightweight fill in slope stability applications

485

Agrobacterium May Delay Plant Nonhomologous End-Joining DNA Repair via XRCC4 to Favor T-DNA Integration  

Science Journals Connector (OSTI)

...benthamiana. Supplemental Figure 3. Estimation of At-XRCC4 Transcript Level...plants are sensitive to ionizing radiation and defective in T-DNA integration...rates in higher plants by low-dose irradiation: Are DNA repair...tumefaciens transformation of the radiation hypersensitive Arabidopsis...

Zarir E. Vaghchhipawala; Balaji Vasudevan; Seonghee Lee; Mustafa R. Morsy; Kirankumar S. Mysore

2012-10-12T23:59:59.000Z

486

Genes Involved in DNA Repair and Nitrosamine Metabolism and Those Located on Chromosome 14q32 Are  

E-Print Network (OSTI)

that nitrosa- mine activation and DNA repair are important in NPC. The consistent down-regulation of expression Ahlquist,4,6 and Allan Hildesheim2 1 Biometric Research Branch, Division of Cancer Treatment and Diagnosis and 2 Hormonal and Reproductive Epidemiology Branch, Division of Cancer Epidemiology and Genetics

Newton, Michael

487

Differential Role of Transcription-Coupled Repair in UVB–Induced Response of Human Fibroblasts and Keratinocytes  

Science Journals Connector (OSTI)

...factor IIH components xeroderma pigmentosum B and p62. J Biol Chem 1998;273:27794-9. 11 van Gool AJ, Citterio E, Rademakers S, et al. The Cockayne syndrome B protein, involved in transcription-coupled DNA repair, resides in an RNA polymerase...

Mariarosaria D'Errico; Massimo Teson; Angelo Calcagnile; Tiziana Nardo; Naomi De Luca; Chiara Lazzari; Silvia Soddu; Giovanna Zambruno; Miria Stefanini; Eugenia Dogliotti

2005-01-15T23:59:59.000Z

488

Applied Studies and Technology (AS&T) | Department of Energy  

Energy Savers (EERE)

Applied Studies and Technology (AS&T) Applied Studies and Technology (AS&T) Applied Studies and Technology (AS&T) DOE established the Environmental Sciences Laboratory (ESL) in...

489

Applied Environmental Microbiology | VIMSS - Virtual Institute for  

NLE Websites -- All DOE Office Websites (Extended Search)

Collection of Soil Samples Collection of Soil Samples Identification of Natural Stressors Profiling of Microbial Population Field and Simulated Conceptual Model Facilities The Applied Environmental Microbiology (AEM) Core is the source of environmental data and samples that determine the stressors that will be studied, pro-vides the environments for growing the organisms to be tested, simulates stressed environments, and verifies the conceptual models to determine how these stress regulatory pathways control the biogeochemistry of contaminated sites. The specific goals of the AEM Core are to: Survey and map DOE sites contaminated by metals and radionuclides using chemical and molecular/ microbiological parameters to determine major microbial populations and potential stressors for Desulfovibrio vulgaris,

490

Determining when NEPA applies to nonfederal activities  

SciTech Connect

More than a quarter century after enactment of the National Environmental Policy Act (NEPA), unresolved questions still persist regarding its applicability to state and private actions. This is particularly true when such projects are undertaken to support the needs of a federal agency. Proposed below is a paradigm for determining when NEPA applies to state or privately conducted, but federally influenced or inspired, actions. The paradigm employs a set of five sequential tests for determining if a state or privately conducted action is subject to the requirements of NEPA.

Eccleston, C.H., Westinghouse Hanford

1996-07-03T23:59:59.000Z

491

6.728 Applied Quantum and Statistical Physics, Fall 2002  

E-Print Network (OSTI)

Elementary quantum mechanics and statistical physics. Introduces applied quantum physics. Emphasizes experimental basis for quantum mechanics. Applies Schrodinger's equation to the free particle, tunneling, the harmonic ...

Bulovic, Vladimir, 1970-

492

Remediation of Mercury and Industrial Contaminants Applied Field...  

Office of Environmental Management (EM)

Remediation of Mercury and Industrial Contaminants Applied Field Research Initiative (RoMIC-AFRI) Remediation of Mercury and Industrial Contaminants Applied Field Research...

493

Apply: Building Energy Efficiency Frontiers and Incubator Technologies...  

Energy Savers (EERE)

Apply: Building Energy Efficiency Frontiers and Incubator Technologies (BENEFIT) - 2014 (DE-FOA-0001027) Apply: Building Energy Efficiency Frontiers and Incubator Technologies...

494

Applying Risk Communication to the Transportation of Radioactive...  

Office of Environmental Management (EM)

Applying Risk Communication to the Transportation of Radioactive Materials Applying Risk Communication to the Transportation of Radioactive Materials Participants should expect to...

495

Rational Catalyst Design Applied to Development of Advanced Oxidation...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Catalyst Design Applied to Development of Advanced Oxidation Catalysts for Diesel Emission Control Rational Catalyst Design Applied to Development of Advanced Oxidation...

496

Applying Climate Information for Adaptation Decision-Making:...  

Open Energy Info (EERE)

Applying Climate Information for Adaptation Decision-Making: A Guidance and Resource Document Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Applying Climate...

497

Grand Challenge for Basic and Applied Research in Hydrogen Storage...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Grand Challenge for Basic and Applied Research in Hydrogen Storage Grand Challenge for Basic and Applied Research in Hydrogen Storage Presentation from the Hydrogen Storage...

498

'Grand Challenge' for Basic and Applied Research in Hydrogen...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

'Grand Challenge' for Basic and Applied Research in Hydrogen Storage Solicitation 'Grand Challenge' for Basic and Applied Research in Hydrogen Storage Solicitation DOE is issuing a...

499

Grand Challenge for Basic and Applied Research in Hydrogen Storage...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Grand Challenge for Basic and Applied Research in Hydrogen Storage: Statement of Objectives Grand Challenge for Basic and Applied Research in Hydrogen Storage: Statement of...

500

James Webb Space Telescope: PM Lessons Applied - Eric Smith,...  

Energy Savers (EERE)

James Webb Space Telescope: PM Lessons Applied - Eric Smith, Deputy Program Director, NASA James Webb Space Telescope: PM Lessons Applied - Eric Smith, Deputy Program Director,...