Statistical Performance Evaluation Of Soft Seat Pressure Relief Valves  

SciTech Connect (OSTI)

Risk-based inspection methods enable estimation of the probability of failure on demand for spring-operated pressure relief valves at the United States Department of Energy's Savannah River Site in Aiken, South Carolina. This paper presents a statistical performance evaluation of soft seat spring operated pressure relief valves. These pressure relief valves are typically smaller and of lower cost than hard seat (metal to metal) pressure relief valves and can provide substantial cost savings in fluid service applications (air, gas, liquid, and steam) providing that probability of failure on demand (the probability that the pressure relief valve fails to perform its intended safety function during a potentially dangerous over pressurization) is at least as good as that for hard seat valves. The research in this paper shows that the proportion of soft seat spring operated pressure relief valves failing is the same or less than that of hard seat valves, and that for failed valves, soft seat valves typically have failure ratios of proof test pressure to set pressure less than that of hard seat valves.

Harris, Stephen P.; Gross, Robert E.

2013-03-26T23:59:59.000Z

2

ANALYSIS OF SAFETY RELIEF VALVE PROOF TEST DATA TO OPTIMIZE LIFECYCLE MAINTENANCE COSTS  

SciTech Connect (OSTI)

Proof test results were analyzed and compared with a proposed life cycle curve or hazard function and the limit of useful life. Relief valve proof testing procedures, statistical modeling, data collection processes, and time-in-service trends are presented. The resulting analysis of test data allows for the estimation of the PFD. Extended maintenance intervals to the limit of useful life as well as methodologies and practices for improving relief valve performance and reliability are discussed. A generic cost-benefit analysis and an expected life cycle cost reduction concludes that $90 million maintenance dollars might be avoided for a population of 3000 valves over 20 years.

Gross, Robert; Harris, Stephen

2007-08-01T23:59:59.000Z

3

Analysis of HFIR pressurizer pump overspeed transients and relief valve performance  

SciTech Connect (OSTI)

The pressurizer pump overspeed transients at the High Flux Isotope Reactor (HFIR) fall in the category of {open_quotes}increase in coolant inventory transients.{close_quotes} They are among the accident transients to be performed for Chapter 15 of the HFIR safety analysis report (SAR). The pressurizer pump speed starting to increase inadvertently to reach its maximum speed of 3,560 rpm while the reactor operates under normal conditions is the cause of this transient. Increased primary coolant system pressure due to increased pressurizer pump flow into the primary coolant head tank challenges the relief valves to open. If the relief valves do not open, increased primary coolant system pressure will challenge the integrity of the high pressure boundary. Two sets of analyses were performed to analyze the pressurizer pump overspeed transients. The purpose of the first analysis is to estimate how long it will take for the relief valves to open under different conditions and whether or not they will chatter or flutter for a considerable amount of time. The analysis estimates relief valve performance and stability using four different relief valve subsystem models. The relief valve subsystem models are not attached to the primary coolant system model. Vigorous pressure oscillations were produced in all of the computations performed as part of the first analysis. The second analysis includes new simulations of the pressurizer pump overspeed transients that were previously simulated using the RELAP5 thermal-hydraulic computer code. The HFIRSYS, High Flux Isotope Reactor System Transient Analysis computer code, was utilized for these simulations providing referable results for comparisons. The increased pressurizer pump flow due to runaway pressurizer pump speed pressurizes the primary coolant system. The assumptions were made in such a way to form constraining conditions at initiation of and during the transients to generate as high an overpressure situation as possible.

Sozer, M.C.

1992-09-11T23:59:59.000Z

4

THE EFFECTS OF MAINTENANCE ACTIONS ON THE PFDavg OF SPRING OPERATED PRESSURE RELIEF VALVES  

SciTech Connect (OSTI)

The safety integrity level (SIL) of equipment used in safety instrumented functions is determined by the average probability of failure on demand (PFDavg) computed at the time of periodic inspection and maintenance, i.e., the time of proof testing. The computation of PFDavg is generally based solely on predictions or estimates of the assumed constant failure rate of the equipment. However, PFDavg is also affected by maintenance actions (or lack thereof) taken by the end user. This paper shows how maintenance actions can affect the PFDavg of spring operated pressure relief valves (SOPRV) and how these maintenance actions may be accounted for in the computation of the PFDavg metric. The method provides a means for quantifying the effects of changes in maintenance practices and shows how these changes impact plant safety.

Harris, S.; Gross, R.

2014-04-01T23:59:59.000Z

5

Investigation Of Adhesion Formation In New Stainless Steel Trim Spring Operated Pressure Relief Valves  

SciTech Connect (OSTI)

Examination of proof test data for new (not previously installed) stainless steel (SS) trim spring operated pressure relief valves (SOPRV) reveals that adhesions form between the seat and disc in about 46% of all such SOPRV. The forces needed to overcome these adhesions can be sufficiently large to cause the SOPRV to fail its proof test (FPT) prior to installation. Furthermore, a significant percentage of SOPRV which are found to FPT are also found to ''fail to open'' (FTO) meaning they would not relief excess pressure in the event of an overpressure event. The cases where adhesions result in FTO or FPT appear to be confined to SOPRV with diameters < 1 in and set pressures < 150 psig and the FTO are estimated to occur in 0.31% to 2.00% of this subpopulation of SS trim SOPRV. The reliability and safety implications of these finding for end-users who do not perform pre-installation testing of SOPRV are discussed.

Gross, Robert E. [Savannah River Site (SRS), Aiken, SC (United States); Bukowski, Julia V. [Villanova University, Villanova, PA (United States); Goble, William M. [exida, Sellersville, PA (United States)

2013-04-16T23:59:59.000Z

6

ESTIMATED SIL LEVELS AND RISK COMPARISONS FOR RELIEF VALVES AS A FUNCTION OF TIME-IN-SERVICE  

SciTech Connect (OSTI)

Risk-based inspection methods enable estimation of the probability of spring-operated relief valves failing on demand at the United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina. The paper illustrates an approach based on application of the Frechet and Weibull distributions to SRS and Center for Chemical Process Safety (CCPS) Process Equipment Reliability Database (PERD) proof test results. The methodology enables the estimation of ANSI/ISA-84.00.01 Safety Integrity Levels (SILs) as well as the potential change in SIL level due to modification of the maintenance schedule. Current SRS practices are reviewed and recommendations are made for extending inspection intervals. The paper compares risk-based inspection with specific SILs as maintenance intervals are adjusted. Groups of valves are identified in which maintenance times can be extended as well as different groups in which an increased safety margin may be needed.

Harris, S.

2012-03-26T23:59:59.000Z

7

Technical evaluation report, TMI action NUREG-0737 (II.D.1), relief and safety valve testing, Comanche Peak, Unit 2, Docket No. 50-446  

SciTech Connect (OSTI)

In the past, safety and relief valves installed in the primary coolant system of light water reactors have performed improperly. As a result, the authors of NUREG-0578 (TMI-2 Lessons Learned Task Force Status Report and Short-Term Recommendations) and, subsequently, NUREG-0737 (Clarification of TMI Action Plan Requirements) recommended development and completion of programs to do two things. First, the programs should reevaluate the functional performance capabilities of pressurized water reactor safety, relief, and block valves. Second, they should verify the integrity of the pressurizer safety and relief valve piping systems for normal, transient, and accident conditions. This report documents the review of those programs by EG&G Idaho, Inc. Specifically, this report documents the review of the Comanche Peak, Unit 2, Applicant response to the requirements of NUREG-0578 and NUREG-0737. This review found the Applicant provided an acceptable response reconfirming they met General Design Criteria 14, 15, and 30 of Appendix A to 10 CFR 50 for the subject equipment.

Fineman, C.P.

1993-01-01T23:59:59.000Z

8

Valve  

DOE Patents [OSTI]

A positive acting valve suitable for operation in a corrosive environment is provided. The valve includes a hollow valve body defining an open-ended bore for receiving two, axially aligned, spaced-apart, cylindrical inserts. One insert, designated the seat insert, terminates inside the valve body in an annular face which lies within plane normal to the axis of the two inserts. An elastomeric O-ring seal is disposed in a groove extending about the annular face. The other insert, designated the wedge insert, terminates inside the valve body in at least two surfaces oppositely inclined with respect to each other and with respect to a plane normal to the axis of the two inserts. An elongated reciprocable gate, movable between the two inserts along a path normal to the axis of the two inserts, has a first flat face portion disposed adjacent and parallel to the annular face of the seat insert. The gate has a second face portion opposite to the first face portion provided with at least two oppositely inclined surfaces for mating with respective inclined surfaces of the wedge insert. An opening is provided through the gate which registers with a flow passage through the two inserts when the valve is open. Interaction of the respective inclined surfaces of the gate and wedge insert act to force the first flat face portion of the gate against the O-ring seal in the seat insert at the limits of gate displacement where it reaches its respective fully open and fully closed positions.

Cho, Nakwon (Knoxville, TN)

1980-01-01T23:59:59.000Z

9

EVALUATION OF SPRING OPERATED RELIEF VALVE MAINTENANCE INTERVALS AND EXTENSION OF MAINTENANCE TIMES USING A WEIBULL ANALYSIS WITH MODIFIED BAYESIAN UPDATING  

SciTech Connect (OSTI)

The Savannah River Site (SRS) spring operated pressure relief valve (SORV) maintenance intervals were evaluated using an approach provided by the American Petroleum Institute (API RP 581) for risk-based inspection technology (RBI). In addition, the impact of extending the inspection schedule was evaluated using Monte Carlo Simulation (MCS). The API RP 581 approach is characterized as a Weibull analysis with modified Bayesian updating provided by SRS SORV proof testing experience. Initial Weibull parameter estimates were updated as per SRS's historical proof test records contained in the Center for Chemical Process Safety (CCPS) Process Equipment Reliability Database (PERD). The API RP 581 methodology was used to estimate the SORV's probability of failing on demand (PFD), and the annual expected risk. The API RP 581 methodology indicates that the current SRS maintenance plan is conservative. Cost savings may be attained in certain mild service applications that present low PFD and overall risk. Current practices are reviewed and recommendations are made for extending inspection intervals. The paper gives an illustration of the inspection costs versus the associated risks by using API RP 581 Risk Based Inspection (RBI) Technology. A cost effective maintenance frequency balancing both financial risk and inspection cost is demonstrated.

Harris, S.; Gross, R.; Mitchell, E.

2011-01-18T23:59:59.000Z

10

Technical evaluation report TMI action -- NUREG-0737 (II.D.1). Relief and safety valve testing, Watts Bar Nuclear Plant, Units 1 and 2 (Dockets 50-390 and 50-391)  

SciTech Connect (OSTI)

In the past, safety and relief valves installed in the primary coolant system of light water reactors have performed improperly. As a result, the authors of NUREG-0578 (TMI-2 Lessons Learned Task Force Status Report and Short-Term Recommendations) and, subsequently, NUREG-0737 (Clarification of TMI Action Plan Requirements) recommended development and completion of programs to do two things. First, they should reevaluate the functional performance capabilities of pressurized water reactor safety, relief, and block valves. Second, they should verify the integrity of the pressurizer safety and relief valve piping systems for normal, transient, and accident conditions. This report documents the review of those programs by Lockheed Idaho Technologies Company. Specifically, this report documents the review of the Watts Bar Nuclear Plant, Units 1 and 2, Applicant response to the requirements of NUREG-0578 and NUREG-0737. This review found the Applicant provided an acceptable response reconfirming they met General Design Criteria 14, 15, and 30 of Appendix A to 10 CFR 50 for the subject equipment. It should also be noted Lockheed Idaho performed this review for both Units 1 and 2. However, the applicability of this review to Unit 2 depends on verifying that the Unit 2 as-built system conforms to the Unit 1 design reviewed in this report.

Fineman, C.P.

1995-02-01T23:59:59.000Z

11

Thermodynamic Characteristic Study of a High-temperature Flow-rate Control Valve for Fuel Supply of Scramjet Engines  

Science Journals Connector (OSTI)

Thermodynamic characteristics are of great importance for the performance of a high-temperature flow-rate control valve, as high-temperature environment may bring problems, such as blocking of spool and increasing of leakage, to the valve. In this paper, a high-temperature flow-rate control valve, pilot-controlled by a pneumatic servo system is developed to control the fuel supply for scramjet engines. After introducing the construction and working principle, the thermodynamic mathematical models of the valve are built based on the heat transfer methods inside the valve. By using different boundary conditions, different methods of simulations are carried out and compared. The steady-state and transient temperature field distribution inside the valve body are predicted and temperatures at five interested points are measured. By comparing the simulation and experimental results, a reasonable 3D finite element analysis method is suggested to predict the thermodynamic characteristics of the high-temperature flow-rate control valve.

Wen ZENG; Zhizhong TONG; Songjing LI; Hongzhou LI; Liang ZHANG

2012-01-01T23:59:59.000Z

12

Probabilistic analysis and operational data in response to NUREG-0737, Item II. K. 3. 2 for Westinghouse NSSS plants. [Modifications to reduce LOCA due to stuck-open power-operated relief valve  

SciTech Connect (OSTI)

This report describes various modifications to Westinghouse plants since TMI and, using probabilistic analysis via event trees, estimates the effect of the post-TMI changes, including an automatic (PORV) (power operated relief valve) isolation concept identified in NUREG-0731 item II.K.3.1. The requested safety valve operational data is included as an appendix. A significant reduction in the frequency of a small break LOCA, due to a stuck open PORV has already been achieved by the modifications made subsequent to TMI. Domestic Westinghouse operating plant data (based on 181 reactor years of operation) has been collected and evaluated. An auto block valve closure system has been evaluated. The analysis is generally applicable to all Westinghouse plants which have incorporated the post-TMI hardware and procedural changes relative to stuck-open PORVs.

Wood, D.C.; Gottshall, C.L.

1981-02-01T23:59:59.000Z

13

Safety valve  

DOE Patents [OSTI]

The safety valve contains a resilient gland to be held between a valve seat and a valve member and is secured to the valve member by a sleeve surrounding the end of the valve member adjacent to the valve seat. The sleeve is movable relative to the valve member through a limited axial distance and a gap exists between said valve member and said sleeve.

Bergman, Ulf C. (Malmoe, SE)

1984-01-01T23:59:59.000Z

14

Check valve  

DOE Patents [OSTI]

A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

Upton, H.A.; Garcia, P.

1999-08-24T23:59:59.000Z

15

Check valve  

DOE Patents [OSTI]

A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion.

Upton, Hubert Allen (Morgan Hill, CA); Garcia, Pablo (Stanford, CA)

1999-08-24T23:59:59.000Z

16

Fast valve  

DOE Patents [OSTI]

A fast valve is disclosed that can close on the order of 7 milliseconds. It is closed by the force of a compressed air spring with the moving parts of the valve designed to be of very light weight and the valve gate being of wedge shaped with O-ring sealed faces to provide sealing contact without metal to metal contact. The combination of the O-ring seal and an air cushion create a soft final movement of the valve closure to prevent the fast air acting valve from having a harsh closing. 4 figs.

Van Dyke, W.J.

1992-04-07T23:59:59.000Z

17

Fast valve  

DOE Patents [OSTI]

A fast valve is disclosed that can close on the order of 7 milliseconds. It is closed by the force of a compressed air spring with the moving parts of the valve designed to be of very light weight and the valve gate being of wedge shaped with O-ring sealed faces to provide sealing contact without metal to metal contact. The combination of the O-ring seal and an air cushion create a soft final movement of the valve closure to prevent the fast air acting valve from having a harsh closing.

Van Dyke, William J. (Grafton, VA)

1992-01-01T23:59:59.000Z

18

Depressurization valve  

DOE Patents [OSTI]

A depressurization valve for use in relieving completely the pressure in a simplified boiling water reactor is disclosed. The normally closed and sealed valve is provided with a valve body defining a conduit from an outlet of a manifold from the reactor through a valve seat. A closing valve disk is configured for fitting to the valve seat to normally close the valve. The seat below the disk is provided with a radially extending annulus extending a short distance into the aperture defined by the seat. The disk is correspondingly provided with a longitudinally extending annulus that extends downwardly through the aperture defined by the seat towards the high pressure side of the valve body. A ring shaped membrane is endlessly welded to the seat annulus and to the disk annulus. The membrane is conformed over the confronted surface of the seat and disk in a C-sectioned configuration to seal the depressurization valve against the possibility of weeping. The disk is held to the closed position by an elongate stem extending away from the high pressure side of the valve body. The stem has a flange configured integrally to the stem for bias by two springs. The first spring acts from a portion of the housing overlying the disk on the stem flange adjacent the disk. This spring urges the stem and attached disk away from the seat and thus will cause the valve to open at any pressure. A second spring-preferably of the Belleville variety-acts on a latch plate surrounding and freely moving relative to the end of the stem. This second spring overcomes the bias of the first spring and any pressure acting upon the disk. This Belleville spring maintains through its spring force the valve in the closed position. At the same time, the latch plate with its freedom of movement relative to the stem allows the stem to thermally expand during valve temperature excursion.

Skoda, G.I.

1989-03-28T23:59:59.000Z

19

Flow metering valve  

DOE Patents [OSTI]

An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

Blaedel, Kenneth L. (Dublin, CA)

1985-01-01T23:59:59.000Z

20

Flow metering valve  

DOE Patents [OSTI]

An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

Blaedel, K.L.

1983-11-03T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Self-regulating valve  

DOE Patents [OSTI]

A variable, self-regulating valve having a hydraulic loss coefficient proportional to a positive exponential power of the flow rate. The device includes two objects in a flow channel and structure which assures that the distance between the two objects is an increasing function of the flow rate. The range of spacing between the objects is such that the hydraulic resistance of the valve is an increasing function of the distance between the two objects so that the desired hydraulic loss coefficient as a function of flow rate is obtained without variation in the flow area.

Humphreys, D.A.

1982-07-20T23:59:59.000Z

22

Nuclear radiation actuated valve  

DOE Patents [OSTI]

A nuclear radiation actuated valve for a nuclear reactor. The valve has a valve first part (such as a valve rod with piston) and a valve second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics. The valve's first part is positioned to receive nuclear radiation from the nuclear reactor's fuel region. The valve's second part is positioned so that its nuclear radiation induced swelling is different from that of the valve's first part. The valve's second part also is positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system.

Christiansen, David W. (Kennewick, WA); Schively, Dixon P. (Richland, WA)

1985-01-01T23:59:59.000Z

23

New safety valve addresses environmental concerns  

SciTech Connect (OSTI)

This paper reports that Conoco Pipeline is using a unique relief valve to reduce costs while improving environmental protection at its facilities. Conoco Pipeline Co. Inc. began testing new relief valves in 1987 to present over-pressuring its pipelines while enhancing the safety, environmental integrity and profitability of its pipelines. Conoco worked jointly with Rupture Pin Technology Inc., Oklahoma City, to seek a solution to a series of safety, environmental, and operational risks in the transportation of crude oil and refined products through pipelines. Several of the identified problems were traced to a single equipment source: the reliability of rupture discs used at pipeline stations to relieve pressure by diverting flow to tanks during over-pressure conditions. Conoco's corporate safety and environmental policies requires solving problems that deal with exposure to hydrocarbon vapors, chemical spills or the atmospheric release of fugitive emissions, such as during rupture disc maintenance. The company had used rupture pin valves as vent relief devices in conjunction with development by Rick Austin of inert gas methods to protect the inner casing wall and outer carrier pipeline wall in pipeline road crossings. The design relies on rupture pin valves set at 5 psi to isolate vent openings from the atmosphere prior to purging the annular space between the pipeline and casing with inert gas to prevent corrosion. Speciality Pipeline Inspection and Engineering Inc., Houston, is licensed to distribute the equipment for the new cased-crossing procedure.

Taylor, J. (Rupture Pin Technology, Inc. Oklahoma City, OK (United States)); Austin, R. (Conoco Pipeline Co., Hennessey, OK (United States))

1992-10-01T23:59:59.000Z

24

Heat transfer rate of a closed-loop oscillating heat pipe with check valves using silver nanofluid as working fluid  

Science Journals Connector (OSTI)

This research investigated the effect of aspect ratios (evaporator length to inner diameter of capillary tube), inclination angles, and concentrations of silver nanofluid on the heat transfer rate of a closed-loo...

S. Wannapakhe; S. Rittidech; B. Bubphachot…

2009-06-01T23:59:59.000Z

25

Artificial Heart Valve Design  

E-Print Network [OSTI]

Artificial Heart Valve Design Your Chance to be a Biomedical Engineer #12;Circulatory System Video #12;What is a Heart Valve? · Heart Valve Video #12;#12;What Does a Heart Valve Do? · Maintain the one direction flow of blood through the heart · Heart valves allow blood to flow through in a forward direction

Provancher, William

26

Improved valve and dash-pot assembly  

DOE Patents [OSTI]

A dash-pot valve comprises a cylinder submerged in the fluid of a housing and have a piston attached to a plunger projecting into the path of closing movement of a pivotal valve member. A vortex chamber in said cylinder is provided with targentially directed inlets to generate vortex flow upon retraction of said plunger and effect increasing resistance against said piston to progressively retard the closing rate of said valve member toward its seat.

Chang, S.C.

1985-04-23T23:59:59.000Z

27

Remote actuated valve implant  

SciTech Connect (OSTI)

Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

2014-02-25T23:59:59.000Z

28

Bellows sealed plug valve  

DOE Patents [OSTI]

A bellows sealed plug valve includes a valve body having an inlet passage and an outlet passage, a valve chamber between the inlet and outlet passages. A valve plug has substantially the same shape as the valve chamber and is rotatably disposed therein. A shaft is movable linearly in response to a signal from a valve actuator. A bellows is sealingly disposed between the valve chamber and the valve actuator and means are located between the bellows and the valve plug for converting linear movement of the shaft connected to the valve actuator to rotational movement of the plug. Various means are disclosed including helical thread mechanism, clevis mechanism and rack and pinion mechanism, all for converting linear motion to rotational motion.

Dukas, Jr., Stephen J. (Idaho Falls, ID)

1990-01-01T23:59:59.000Z

29

Valves: Corrosion and maintenance  

SciTech Connect (OSTI)

A mill setting is without doubt a harsh, demanding environment for valves. In a polling of valve suppliers, several areas were identified as the most corrosive to valves, particularly chemical pulping, bleaching, chemical recovery, and waste-water treatment. In some uses, a valve may only last 12-18 months. Depending on the alloy and seat material used, the life expectancy can also exceed 10 years in some applications. This survey of valve manufacturers gives basic tips on selecting, protecting, and maintaining valves.

Meadows, D.G.

1993-08-01T23:59:59.000Z

30

Active combustion flow modulation valve  

DOE Patents [OSTI]

A flow modulation valve has a slidably translating hollow armature with at least one energizable coil wound around and fixably attached to the hollow armature. The energizable coil or coils are influenced by at least one permanent magnet surrounding the hollow armature and supported by an outer casing. Lorentz forces on the energizable coils which are translated to the hollow armature, increase or decrease the flow area to provide flow throttling action. The extent of hollow armature translation depends on the value of current supplied and the direction of translation depends on the direction of current flow. The compact nature of the flow modulation valve combined with the high forces afforded by the actuator design provide a flow modulation valve which is highly responsive to high-rate input control signals.

Hensel, John Peter; Black, Nathaniel; Thorton, Jimmy Dean; Vipperman, Jeffrey Stuart; Lambeth, David N; Clark, William W

2013-09-24T23:59:59.000Z

31

Overflow control valve  

DOE Patents [OSTI]

An overflow control valve for use in a liquid sodium coolant pump tank which valve can be extended to create a seal with the pump tank wall or retracted to break the seal thereby accommodating valve removal. An actuating shaft which controls valve disc position also has cams which bear on roller surfaces to force retraction of a sliding cylinder against spring tension to retract the cylinder from sealing contact with the pump tank.

Hundal, Rolv (Hempfield, PA); Kessinger, Boyd A. (Murrysville, PA); Parlak, Edward A. (North Huntingdon, PA)

1984-07-24T23:59:59.000Z

32

Piping retrofit reduces valve-damaging flow vibration  

SciTech Connect (OSTI)

This article describes how excessive flow-induced vibration was escalating safety relief valve maintenance at an alarming pace until simple piping modifications eliminated the problem. Public Service Co. of Colorado's (PSCO) Cherokee Station Unit 4 had been experiencing excessive hot and cold reheat safety valve maintenance. From 1990 through 1993, expenditures exceeded $150,000, including a complete refurbishing in 1990. Furthermore, from 1990 to 1992 the incurred costs of contracting VR certificate repairs accumulated to more than $50,000. Such exorbitant maintenance costs were unique among PSCO's generating system.

Webb, M.; Ellenberger, P.

1995-01-01T23:59:59.000Z

33

Mud saver valve  

SciTech Connect (OSTI)

This patent describes a mud saver valve for retaining drilling fluid in the kelly of a rotary drilling rig. It comprises: a kelly sub defining an open-ended elongated body having threaded ends for forming a connection between the kelly and a drill pipe string; an enlarged bore formed in said elongated body; a tubular body received within said enlarged bore of said elongated body, said tubular body including an enlarged portion defining a shoulder for engagement with a shoulder formed in said elongated body; hollow piston means axially disposed within said tubular body. The piston means being axially movable relative to said tubular body and defining a fluid passage therethrough; valve means removably mounted within said tubular body. The valve means cooperating with said piston means to normally close the fluid passage through said piston means, wherein said valve means is movable between a first and second position; a stop member removably connected to said tubular body. The stop member including a first internal circumferential tapered shoulder for limiting downward movement of said valve means; and means for urging said piston means into engagement with said valve means.

Baugh, B.F.

1990-02-13T23:59:59.000Z

34

Science Against Stress: Research Shows Way to Some Cellular Relief...  

Energy Savers [EERE]

Science Against Stress: Research Shows Way to Some Cellular Relief Science Against Stress: Research Shows Way to Some Cellular Relief December 30, 2011 - 10:14am Addthis...

35

Social buffering: relief from stress and anxiety  

Science Journals Connector (OSTI)

...Lundeberg, T2002Social stress blocks energy conservation in rats exposed to an oxytocin-injected...unwanted pregnancies. Am. J. Public Health. 63, 935-938. Morris...relief from stress and anxiety. | Communication is essential to members of a...

2006-01-01T23:59:59.000Z

36

Fast closing valve  

DOE Patents [OSTI]

A valve is provided for protecting the high vacuum of a particle accelera in the event of air leakage, wherein the valve provides an axially symmetrical passage to avoid disturbance of the partical beam during normal operation, and yet enables very rapid and tight closure of the beam-carrying pipe in the event of air leakage. The valve includes a ball member (30) which can rotate between a first position wherein a bore (32) in the member is aligned with the beam pipe, and a second position out of line with the pipe. A seal member (38) is flexibly sealed to the pipe, and has a seal end which can move tightly against the ball member after the bore has rotated out of line with the pipe, to thereby assure that the seal member does not retard rapid rotation of the ball valve member. The ball valve member can be rapidly rotated by a conductive arm (40) fixed to it and which is rotated by the discharge of a capacitor bank through coils (44, 45) located adjacent to the arm.

Hanson, Clark L. (Livermore, CA)

1984-01-10T23:59:59.000Z

37

Valve stem and packing assembly  

DOE Patents [OSTI]

A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents over tightening of the retaining nut and the resulting excessive friction between stem and stem packing. 2 figures.

Wordin, J.J.

1991-09-03T23:59:59.000Z

38

Valve stem and packing assembly  

DOE Patents [OSTI]

A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

Wordin, John J. (Bingham County, ID)

1991-01-01T23:59:59.000Z

39

Plastic-lined valves are virtually trouble-free in caustic, acid pipelines  

SciTech Connect (OSTI)

Chevron renovated the naphthenic acid plant, part of the Pascagoula, Mississippi Refinery of Chevron U.S.A. Inc., in mid-1979. They installed plastic-lined valves in the caustic and acid water piping systems. The valves combine the excellent sealing characteristics of a plug valve with the minimal rotary contact surface and low pressure drop of a butterfly valve. The valve has a molded-in-place PTFE liner resistant to abrasives and corrosives at temperatures of 450/sup 0/F, and is rated for pressures from full vacuum to 150 psi.

Not Available

1983-02-01T23:59:59.000Z

40

Valve for gas centrifuges  

DOE Patents [OSTI]

The invention is pneumatically operated valve assembly for simulatenously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two on the lines so closed. The value assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

Hahs, C.A.; Rurbage, C.H.

1982-03-17T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

RATES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Planning & Projects Planning & Projects Power Marketing Rates You are here: SN Home page > Power Marketing > RATES Rates and Repayment Services Rates Current Rates Power Revenue Requirement Worksheet (FY 2014) (Oct 2013 - Sep 2014) (PDF - 30K) PRR Notification Letter (Sep 27, 2013) (PDF - 959K) FY 2012 FP% True-Up Calculations(PDF - 387K) Variable Resource Scheduling Charge FY12-FY16 (October 1, 2012) PRR Forecast FY14-FY17 (May 23, 2013) (PDF - 100K) Forecasted Transmission Rates (May 2013) (PDF - 164K) Past Rates 2013 2012 2011 2010 2009 Historical CVP Transmission Rates (April 2013) (PDF - 287K) Rate Schedules Power - CV-F13 - CPP-2 Transmission - CV-T3 - CV-NWT5 - PACI-T3 - COTP-T3 - CV-TPT7 - CV-UUP1 Ancillary - CV-RFS4 - CV-SPR4 - CV-SUR4 - CV-EID4 - CV-GID1 Federal Register Notices - CVP, COTP and PACI

42

RATES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Marketing > RATES Marketing > RATES RATES Current Rates Past Rates 2006 2007 2008 2009 2010 2011 2012 Rates Schedules Power CV-F13 CPP-2 Transmissions CV-T3 CV-NWT5 PACI-T3 COTP-T3 CV-TPT7 CV-UUP1 Ancillary CV-RFS4 CV-SPR4 CV-SUR4 CV-EID4 CV-GID1 Future and Other Rates SNR Variable Resource Scheduling Charge FY12-FY16 (October 1, 2012) SNR Rates Process Calendar (PDF - 171K) Procedures Informal Process Transmission Action Items List (PDF - 144K) Power Action Item List updated on 4-27-10 (PDF - 155K) Power Action Item List (Quick links to relevant documents) Formal Process Rates Brochure (01/11/2011) (PDF - 900K) Appendix A - Federal Register Notice (01/03/2011) (PDF - 8000K) Appendix B - Central Valley Project Power Repayment Study (PDF - 22,322K) Appendix C - Development of the CVP Cost of Service Study (PDF - 2038K)

43

RATES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

RATES RATES Rates Document Library SNR Rates Process Calendar (PDF - 171K) Procedures Informal Process Transmission Action Items List (PDF - 144K) Power Action Item List updated on 4-27-10 (PDF - 155K) Power Action Item List (Quick links to relevant documents) Formal Process Rates Brochure (01/11/2011) (PDF - 900K) Appendix A - Federal Register Notice (01/03/2011) (PDF - 8000K) Appendix B - Central Valley Project Power Repayment Study (PDF - 22,322K) Appendix C - Development of the CVP Cost of Service Study (PDF - 2038K) Appendix D - Western Transmission System Facilities Map (PDF - 274K) Appendix E - Estimated FY12 FP and BR Customer (PDF - 1144K) Appendix F - Forecasted Replacements and Additions FY11 - FY16 (PDF - 491K) Appendix G - Definitions (PDF - 1758K) Appendix H - Acronyms (PDF - 720K)

44

Fast-acting valve and uses thereof  

DOE Patents [OSTI]

A very fast acting valve capable of producing a very well-defined plug of gas suitable for filling a theta pinch vacuum vessel is given. The valve requires no springs, instead being stopped mainly by a nonlinear force. Thus, the valve is not subject to bouncing; and the ratio of the size of the valve housing to the size of the valve stem is smaller than it would be if springs were needed to stop the valve stem. Furthermore, the valve can be used for thousands of valve firings with no apparent valve damage.

Meyer, James A. (Espanola, NM)

1982-01-01T23:59:59.000Z

45

Fast-acting valve and uses thereof  

DOE Patents [OSTI]

A very fast acting valve capable of producing a very well-defined plug of gas suitable for filling a theta pinch vacuum vessel is given. The valve requires no springs, instead being stopped mainly by a nonlinear force. Thus, the valve is not subject to bouncing; and the ratio of the size of the valve housing to the size of the valve stem is smaller than it would be if springs were needed to stop the valve stem. Furthermore, the valve can be used for thousands of valve firings with no apparent valve damage.

Meyer, J.A.

1980-05-16T23:59:59.000Z

46

Semi-active compressor valve  

DOE Patents [OSTI]

A method and system for fine-tuning the motion of suction or discharge valves associated with cylinders of a reciprocating gas compressor, such as the large compressors used for natural gas transmission. The valve's primary driving force is conventional, but the valve also uses an electromagnetic coil to sense position of the plate (or other plugging element) and to provide an opposing force prior to impact.

Brun, Klaus (Helotes, TX); Gernentz, Ryan S. (San Antonio, TX)

2010-07-27T23:59:59.000Z

47

Internal combustion engine intake valve  

SciTech Connect (OSTI)

In a inlet valve for use in an internal combustion engine in which the valve has a stem and a head, the head having, when seated, a first side positioned within a combustion chamber of an engine block and a second, opposite, side attached to the stem, the second side including that piston of the head forming the seat with the engine block when the valve is in a seated position, and first side including that portion of the head from the seat toward the chamber when the valve is in the seated position, and the engine including means for moving the valve from the closed position to an open position to allow a fuel mixture to enter the chamber, the improvement in the valve comprising: an extension ridge from the first side, positioned in alignment with the periphery of the valve head, the ridge forming with the seat a single, continuous, smooth outer surface along the periphery thereof for reducing the coefficient of drag of the fuel entering the chamber around the valve head when the valve is in the open position.

Mosler, W.B.

1988-10-25T23:59:59.000Z

48

Computations of high-pressure steam flow in the turbine bypass valve  

SciTech Connect (OSTI)

The objective of the present study is to investigate the steam flow behavior through the high-pressure turbine bypass valve. Efforts have mainly been directed at investigating the process of steam flow and property variations aforementioned bypass valve as well as to obtain correlations between the flow rate and the valve opening ratio. Modeling of the high-pressure turbulent steam flow was performed on a three-dimensional non-staggered grid system by employing the finite volume method and by solving the three-dimensional, turbulent, compressible Navier-Stokes, and energy equations. Through this research, numerous data have been acquired and analyzed. These efforts enable one to obtain a correlation data set for the valve opening versus flow rate coefficient of the valve. One of the significant accomplishments is to use the model presented here to further improve a design of a turbine bypass flow valve.

Amano, R.S.; Draxler, G.R.

1999-07-01T23:59:59.000Z

49

Redesigned recycle valves abate compressor vibration  

SciTech Connect (OSTI)

New recycle valves installed in 1994 on the compressors in the East Brae field in the North Sea corrected the noise and vibration problem that damaged the original valves shortly after commissioning the platform. The original recycle valves, especially on the second-stage compressors, showed severe damage. The paper describes the Brae field, the recycle system, recycle valves, operations, the new valve design, noise and vibration, and valve actuators.

Laing, D.E. [Marathon Oil U.K. Ltd., Aberdeen (United Kingdom); Miller, H.L.; McCaskill, J.W. [Engineering Control Components Inc., Rancho Santa Margarita, CA (United States)

1995-06-05T23:59:59.000Z

50

Safety relief valve sizing: comparison of two-phase flow models to empirical data  

E-Print Network [OSTI]

~ TPHEM, Kf=4tUD 0. 4 0. 3 Q g j 0. 2 -0. 003 -0. 002 -0. 001 0. 000 0. 001 0. 002 0. 003 0. 004 0. 005 Xo Figure 3: Sozzi and Sutherland Nozzle ?2, L = 12. 5 in 0. 8 0. 7 tt Data a HNE, Kf=4fUD 0. 6 e TPHEM Pipe e=0. 0004 ~M 0. 5 ~ TPHEM, Kf... 'ID gi ~ ~ E ~ 0. 2 -0. 005 -0. 004 -0. 003 -0. 002 -0. 001 0. 000 0. 001 0. 002 0. 003 0. 004 0. 005 Xo Figure 5: Sozzi and Sutherland Nozzle ?2, L = 20. 0 in 0. 8 0. 7 ~ HNE, Kf=afUD 0. 6 ~M0. 5 0. 4 'a D D ~ cpa D e TPHEM Rpe e=0...

Meiller, Paul Robert

2013-02-22T23:59:59.000Z

51

Surge-damping vacuum valve  

DOE Patents [OSTI]

A valve having a mechanism for damping out flow surges in a vacuum system which utilizes a slotted spring-loaded disk positioned adjacent the valve's vacuum port. Under flow surge conditions, the differential pressure forces the disk into sealing engagement with the vacuum port, thereby restricting the flow path to the slots in the disk damping out the flow surge.

Bullock, Jack C. (Pleasanton, CA); Kelly, Benjamin E. (Tracy, CA)

1980-01-01T23:59:59.000Z

52

E-Print Network 3.0 - actuated ball valve Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Xuan-Qi Wang, Howen Mak, and Yu-Chong Tai Summary: valve design to maximize flow rates. Pump 1st Generation The solenoid actuator produced a reciprocating... : Flow Rate vs....

53

Control valve for solar heating systems  

SciTech Connect (OSTI)

A control valve for a solar heating system is disclosed. The valve has a valve body which defines four chambers disposed end to end. A valve operating rod is movable axially through all four chambers under motor control and carries a valve member for directing liquid through the valve. In one position of the valve member, incoming liquid is directed to an outlet for connection to a solar collector and liquid returning from the collector can flow through the valve body and back to the swimming pool. In the other position of the valve member, the liquid bypasses the collector and is directed back to the pool while liquid in the collector drains back into the valve body through the outlet and is removed by suction from a drain-down chamber in the valve body.

Stewart, J.M.

1981-12-29T23:59:59.000Z

54

Annular flow control safety valve  

SciTech Connect (OSTI)

A tubular housing having an inner tubular member forms an inner passageway inside of the inner member and an outer passageway between the inner member and the housing. The housing has valve openings leading from the outer passageway to the exterior of the housing and a tubular valve closure member telescopically moves on the interior of the housing. First means move the valve closure member in an upper direction for closing the openings and at least one actuating piston is telescopically movable within and has its longitudinal axis in the wall of the housing and engages the valve closure member. The piston is in communication with a hydraulic passageway adapted to extend to the well surface for actuating the closure member in a direction to open the valve openings. The closure member is positioned whereby upward flow through the outer passageway acts on the closure member to close the valve opening. At least one lockout piston telescopically moves within the housing and is actuated from the surface and is engageable with holding means in the housing for providing a hydraulic lockout for the valve. Shear means may be provided between the lockout piston and the housing for controlling the hydraulic lockout. A single seal is provided between the closure member and the housing and is positioned below the opening and exposed to the pressure on both sides when the valve is opened. Preferably the actuating pistons are connected to the valve closure member but the hydraulic lockout pistons engage but are unconnected to the valve closure member.

Black, P.W.; Pringle, R.E.

1981-06-16T23:59:59.000Z

55

Valving for controlling a fluid-driven reciprocating apparatus  

DOE Patents [OSTI]

A pair of control valve assemblies for alternately actuating a pair of fluid-driven free-piston devices by using fluid pressure communication therebetween. Each control valve assembly is switched by a pressure signal depending on the state of its counterpart's piston. The communication logic is arranged to provide overlap of the forward strokes of the pistons, so that at least one of the pair will always be pressurized. Thus, uninterrupted pumping of liquid is made possible from a pair of free-piston pumps. In addition, the speed and frequency of piston stroking is entirely dependent on the mechanical power load applied. In the case of a pair of pumps, this enables liquid delivery at a substantially constant pressure over the full range of flow rates, from zero to maximum flow. Each of the valve assemblies uses an intake-exhaust valve and a signal valve with the signal valve of one pump being connected to be pressure responsive to the piston of the opposite cylinder or pump.

Whitehead, John C. (Davis, CA)

1995-01-01T23:59:59.000Z

56

Valving for controlling a fluid-driven reciprocating apparatus  

DOE Patents [OSTI]

A pair of control valve assemblies is described for alternately actuating a pair of fluid-driven free-piston devices by using fluid pressure communication therebetween. Each control valve assembly is switched by a pressure signal depending on the state of its counterpart`s piston. The communication logic is arranged to provide overlap of the forward strokes of the pistons, so that at least one of the pair will always be pressurized. Thus, uninterrupted pumping of liquid is made possible from a pair of free-piston pumps. In addition, the speed and frequency of piston stroking is entirely dependent on the mechanical power load applied. In the case of a pair of pumps, this enables liquid delivery at a substantially constant pressure over the full range of flow rates, from zero to maximum flow. Each of the valve assemblies uses an intake-exhaust valve and a signal valve with the signal valve of one pump being connected to be pressure responsive to the piston of the opposite cylinder or pump. 15 figs.

Whitehead, J.C.

1995-06-27T23:59:59.000Z

57

Development of a thyristor valve for next generation 500kV HVDC transmission systems  

SciTech Connect (OSTI)

A high voltage thyristor valve is the basic component of an HVDC transmission system. Development of a 500kV valve for next generation HVDC transmission systems is described. First, the power loss of the valve is analyzed to decide a reasonable wafer size for the light triggered thyristor. From these results, a six inch diameter wafer size is selected. The light triggered thyristor, with ratings of 8kV and 3.5kA, is developed using the six inch wafer. The designing of the valve employing the thyristor and test results with the prototype valve prove that a 500kV valve can be realized by the design method.

Hasegawa, T. [Kansai Electric Power Co., Inc., Osaka (Japan)] [Kansai Electric Power Co., Inc., Osaka (Japan); Yamaji, K. [Shikoku Electric Power Co., Inc., Takamatsu (Japan)] [Shikoku Electric Power Co., Inc., Takamatsu (Japan); Irokawa, H. [Electric Power Development Co., Ltd., Tokyo (Japan)] [Electric Power Development Co., Ltd., Tokyo (Japan); Shirahama, H.; Tanaka, C.; Akabane, K.

1996-10-01T23:59:59.000Z

58

Cavitation guide for control valves  

SciTech Connect (OSTI)

This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

Tullis, J.P. [Tullis Engineering Consultants, Logan, UT (United States)

1993-04-01T23:59:59.000Z

59

Valve for controlling solids flow  

DOE Patents [OSTI]

A fluidized solids control valve is disclosed that is particularly well adapted for use with a flow of coal or char that includes both large particles and fines. The particles may or may not be fluidized at various times during the operation. The valve includes a tubular body that terminates in a valve seat covered by a normally closed closure plate. The valve body at the seat and the closure plate is provided with aligned longitudinal slots that receive a pivotally supported key plate. The key plate is positionable by an operator in inserted, intermediate and retracted positions respecting the longitudinal slot in the valve body. The key plate normally closes the slot within the closure plate but is shaped and aligned obliquely to the longitudinal slot within the valve body to provide progressively increasing slot openings between the inserted and retracted positions. Transfer members are provided between the operator, key plate and closure plate to move the closure plate into an open position only when the key plate is retracted from the longitudinal slot within the valve body.

Feldman, David K. (Fairlawn, NJ)

1980-01-01T23:59:59.000Z

60

Steam Turbine Control Valve Noise  

Science Journals Connector (OSTI)

Although noise problems with steam turbine control valves have existed before they have become more prominent with nuclear turbines whose valves range to 20 in. in diameter. Our first?generation nuclear control valves were unacceptably noisy when operating under chocked conditions. These noise levels have been ameliorated by incorporation of a valve cage with numerous small holes. Rational design rules for this “dispersive muffler” have been developed from published multiple?jet noise data and improved through our own tests. However we are also evaluating other low?noise valve configurations which are consistent with turbine requirements. The approach we are developing is to investigate the internal aerodynamic noisegeneration in small air model tests and to combine this with measurements of pipe?wall transmission characteristics (being reported separately) to predict externally radiated noise. These predictions will be checked in a new steam test facility for complete scale?model valves. The small air tests show that acoustic efficiencies of throttling valve flows tend to vary with third power of Mach number when exhausting into space and with a lesser power when enclosed in a downstream pipe. At some pressure ratios narrow?band spikes appear in the spectrum and for some configurations step changes in sound power are associated with transitions in flow regimes.

Frank J. Heymann; Michael A. Staiano

1973-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Heart valve tissue engineering Frank Baaijens  

E-Print Network [OSTI]

Heart valve tissue engineering Frank Baaijens Department of Biomedical Engineering Eindhoven University of Technology Netherlands Tissue engineered heart valves appear promising as autologous valvular functionality and durability of the heart valve relies on the strength and anisotropic properties of the valve

Stavroulakis, Georgios E.

62

Heart Valve Lesson Plan Biomedical Engineering  

E-Print Network [OSTI]

Heart Valve Lesson Plan Biomedical Engineering Objective · Introduce students to biomedical Learning Outcomes · Students will understand the role and function of heart valves. · Students will learn does a heart valve work? · Why do we need to replace heart valves? Time Required (Itemized) · Lecture

Provancher, William

63

Flow Characteristics Analysis of Widows' Creek Type Control Valve for Steam Turbine Control  

SciTech Connect (OSTI)

The steam turbine converts the kinetic energy of steam to mechanical energy of rotor blades in the power conversion system of fossil and nuclear power plants. The electric output from the generator of which the rotor is coupled with that of the steam turbine depends on the rotation velocity of the steam turbine bucket. The rotation velocity is proportional to the mass flow rate of steam entering the steam turbine through valves and nozzles. Thus, it is very important to control the steam mass flow rate for the load following operation of power plants. Among various valves that control the steam turbine, the control valve is most significant. The steam flow rate is determined by the area formed by the stem disk and the seat of the control valve. While the ideal control valve linearly controls the steam mass flow rate with its stem lift, the real control valve has various flow characteristic curves pursuant to the stem lift type. Thus, flow characteristic curves are needed to precisely design the control valves manufactured for the operating conditions of nuclear power plants. OMEGA (Optimized Multidimensional Experiment Geometric Apparatus) was built to experimentally study the flow characteristics of steam flowing inside the control valve. The Widows' Creek type control valve was selected for reference. Air was selected as the working fluid in the OMEGA loop to exclude the condensation effect in this simplified approach. Flow characteristic curves were plotted by calculating the ratio of the measured mass flow rate versus the theoretical mass flow rate of the air. The flow characteristic curves are expected to be utilized to accurately design and operate the control valve for fossil as well as nuclear plants. (authors)

Yoo, Yong H.; Sohn, Myoung S.; Suh, Kune Y. [PHILOSOPHIA, Inc., Seoul National University, San 56-1 Sillim-dong, Gwanak-gu, Seoul, 151-742 (Korea, Republic of)

2006-07-01T23:59:59.000Z

64

Friction and Wear Reduction in Diesel Engine Valve Trains | Department...  

Broader source: Energy.gov (indexed) [DOE]

More Documents & Publications Mechanisms of Oxidation-Enhanced Wear in Diesel Exhaust Valves Materials for Advanced Engine Valve Train Materials for Advanced Engine Valve Train...

65

Development of Lashless Valve Train Technology | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Lashless Valve Train Technology Development of Lashless Valve Train Technology This poster covers Jacobs history of lashless valve train efforts, design, simulation, engine...

66

Corrosion in HVDC valve cooling systems  

SciTech Connect (OSTI)

Stainless steel couplings in the main cooling water pipes of HVDC thyristor valves have been in use since 1983, with an overall satisfactory behavior. However, some water leakage due to corrosion below the sealing O-rings of the couplings was observed during 1992. An extensive investigation and follow-up worldwide showed a direct correlation between water quality and the corrosion rate of the stainless steel couplings. Recommendations are given about actions to be taken in order to maintain a long lifetime for the fine water systems.

Jackson, P.O.; Abrahamsson, B.; Gustavsson, D.; Igetoft, L.

1997-04-01T23:59:59.000Z

67

Pressure Relief Devices for High-Pressure Gaseous Storage Systems...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Pressure Relief Devices for High-Pressure Gaseous Storage Systems: Applicability to Hydrogen Technology A. Kostival, C. Rivkin, W. Buttner, and R. Burgess National Renewable Energy...

68

Noninvasive valve monitor using alternating electromagnetic field  

DOE Patents [OSTI]

One or more electrical coils are carefully located on the outside of a valve body. An alternating current passing through the coil(s) results in an alternating electromagnetic field being transmitted into the valve body and valve internals. The electromagnetic field varies in intensity and polarity in the valve. As the position of a valve internal part is changed, the electromagnetic field throughout the valve body and its internals is altered. A passive receiver coil carefully located on the outside of the valve body detects the intensity of the electromagnetic field at that location as an induced electrical voltage in the coil. With the change in position of the valve internal part, there is a corresponding change in the induced voltage as a result of the alteration in the alternating electromagnetic field at that location. Changes in the voltage provide an indication of the position and motion of valve internals.

Eissenberg, David M. (Oak Ridge, TN); Haynes, Howard D. (Knoxville, TN); Casada, Donald A. (Knoxville, TN)

1993-01-01T23:59:59.000Z

69

Annular flow diverter valve  

DOE Patents [OSTI]

A valve for diverting flow from the center of two concentric tubes to the annulus between the tubes or, operating in the reverse direction, for mixing fluids from concentric tubes into a common tube and for controlling the volume ratio of said flow consists of a toroidal baffle disposed in sliding engagement with the interior of the inner tube downstream of a plurality of ports in the inner tube, a plurality of gates in sliding engagement with the interior of the inner tube attached to the baffle for movement therewith, a servomotor having a bullet-shaped plug on the downstream end thereof, and drive rods connecting the servomotor to the toroidal baffle, the servomotor thereby being adapted to move the baffle into mating engagement with the bullet-shaped plug and simultaneously move the gates away from the ports in the inner tube and to move the baffle away from the bullet-shaped plug and simultaneously move the gates to cover the ports in the inner tube.

Rider, Robert L. (Walkersville, MD)

1980-01-01T23:59:59.000Z

70

An electromechanical valve drive incorporating a nonlinear mechanical transformer  

E-Print Network [OSTI]

In traditional internal combustion engines, a camshaft acts on the valve stems to open and close the valves. Valve timing is fixed relative to piston position. On the other hand, if a valve is flexibly controlled by a ...

Chang, Woo Sok, 1964-

2003-01-01T23:59:59.000Z

71

Failure Modes and Causes for Swing and Lift Type Check Valves  

Office of Scientific and Technical Information (OSTI)

HPCI Mainsteam RCIC Suppression Isolation Air Pool Support Figure 2. Relative Failure Rate by System and Valve Type for Significant 191-1996 Failures for the Ten Systems with...

72

Effect of reactor conditions on MSIV (main steam isolation valves)-ATWS power level  

SciTech Connect (OSTI)

In a boiling water reactor (BWR) when there is closure of the main steam isolation valves (MSIVs), the energy generated in the core will be transferred to the pressure suppression pool (PSP) via steam flows out of the relief valves. The pool has limited capacity as a heat sink and hence, if there is no reactor trip (an ATWS event), there is the possibility that the pool temperature may rise beyond acceptable limits. The present study was undertaken to determine how the initial reactor conditions affect the power during an MSIV-ATWS event. The time of interest is during the 20-30 minute period when it is assumed that the reactor is in a quasi-equilibrium condition with the water level and pressure fixed, natural circulation conditions and no control rod movement or significant boron in the core. The initial conditions of interest are the time during the cycle and the operating state. 4 refs., 2 tabs.

Diamond, D.J.

1987-01-01T23:59:59.000Z

73

American Valve: Order (2010-CW-1411)  

Broader source: Energy.gov [DOE]

DOE ordered American Valve, Inc. to pay a $5,000 civil penalty after finding American Valve had failed to certify that certain showerhead models comply with the applicable water conservation standards.

74

Real-Time Relief Mapping on Arbitrary Polygonal Surfaces Fabio Policarpo  

E-Print Network [OSTI]

Figure 1: Teapot rendered with different relief textures using per-pixel lighting and self, the teapot and the walls were rendered using relief mapping. In this paper, we show how relief textures can

Oliveira, Manuel M.

75

Self Contained Temperature Actuated Control Valves  

E-Print Network [OSTI]

Ogontz Controls Company, P.O. Box 479, Willow Grove, Pennsylvania, 19090. FREEZ AND SCALD PROTECTION OUTDOOR EMERGENCY SHOWER = t' ",. 362 ESL-IE-79-04-39 Proceedings from the First Industrial Energy Technology Conference Houston, TX, April 22... control valves and surface temperature control valves (to provide setqp and freeze protection), fluid sensing control valves, air fluid sensing control valves, safety shower val~es (to provide both freeze and scald protection) and condensate freeze...

Pirkle, F.

1979-01-01T23:59:59.000Z

76

Lockout housing and sleeve for safety valve  

SciTech Connect (OSTI)

This patent describes apparatus for use in a subsurface valve. It comprises a lockout housing; and a lockout sleeve.

Dickson, R.L.; Davis, G.R.

1992-07-07T23:59:59.000Z

77

Fast-acting valve actuator  

DOE Patents [OSTI]

A fast-acting valve actuator utilizes a spring driven pneumatically loaded piston to drive a valve gate. Rapid exhaust of pressurized gas from the pneumatically loaded side of the piston facilitates an extremely rapid piston stroke. A flexible selector diaphragm opens and closes an exhaust port in response to pressure differentials created by energizing and de-energizing a solenoid which controls the pneumatic input to the actuator as well as selectively providing a venting action to one side of the selector diaphragm.

Cho, Nakwon (Knoxville, TN)

1980-01-01T23:59:59.000Z

78

CONTROL VALVE TESTING PROCEDURES AND EQUATIONS  

E-Print Network [OSTI]

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS #12;APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS 2 Cv Q P Sg net gpm net = / Cv = Q P / Sg 75 in this report is per Instrument Society of America S39.2 testing specifications for control valves. The main

Rahmeyer, William J.

79

Dynamic Testing of Check Valves William Rahmeyer  

E-Print Network [OSTI]

Dynamic Testing of Check Valves William Rahmeyer Professor of Civil and Environmental Engineering;1 DYNAMIC FLOW TESTING OF CHECK VALVES by William Rahmeyer, Professor of Civil and Environmental Engineering objectives of this paper are: (1) to present a test method by which check valves can be dynamically tested

Rahmeyer, William J.

80

Valve for fuel pin loading system  

DOE Patents [OSTI]

A cyclone valve surrounds a wall opening through which cladding is projected. An axial valve inlet surrounds the cladding. Air is drawn through the inlet by a cyclone stream within the valve. An inflatable seal is included to physically engage a fuel pin subassembly during loading of fuel pellets.

Christiansen, D.W.

1984-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Valve for fuel pin loading system  

DOE Patents [OSTI]

A cyclone valve surrounds a wall opening through which cladding is projected. An axial valve inlet surrounds the cladding. Air is drawn through the inlet by a cyclone stream within the valve. An inflatable seal is included to physically engage a fuel pin subassembly during loading of fuel pellets.

Christiansen, David W. (Kennewick, WA)

1985-01-01T23:59:59.000Z

82

Sizing sliding gate valves for steam service  

SciTech Connect (OSTI)

Sliding gate valves have been used in thousands of applications during the past 40 yr. While steam control is a common application for these valves, thy are also used to control other gases and liquids. The sliding gate design provides straight-through flow, which minimizes turbulence, vibration, and noise. Seats are self-cleaning and self-lapping to provide a tight, long-lasting shutoff. A correctly sized valve is essential for accurate control. Valve size should be determined by service and system requirements, not by the size of the existing pipeline. Sizing a valve on the basis of pipeline size usually results in an oversized valve and poor control. Generally, regulator size is smaller than pipe size. Whenever complete information is known (inlet pressure, outlet pressure, or pressure drop, and required flow), determine the valve flow coefficient (C{sub v}) using the equations in ANSI/ISA S75.01 or a flow sizing chart. Tables of values for various types of valves are available from manufacturers. However, when complete system requirements are not known, valve oversizing is prevented by determining the design capacity of piping downstream from the valve. The valve should not be sized to pass more flow than the maximum amount the pipe can handle at a reasonable velocity. An example calculation is given.

Bollinger, R. [Jordan Value, Cincinnati, OH (United States)

1995-11-06T23:59:59.000Z

83

Evaluation of silicon-nitride ceramic valves.  

SciTech Connect (OSTI)

Silicon-nitride ceramic valves can improve the performance of both light- and heavy-duty automotive engines because of the superior material properties of silicon nitrides over current metal alloys. However, ceramics are brittle materials that may introduce uncertainties in the reliability and durability of ceramic valves. As a result, the lifetime of ceramic valves are difficult to predict theoretically due to wide variations in the type and distribution of microstructural flaws in the material. Nondestructive evaluation (NDE) methods are therefore required to assess the quality and reliability of these valves. Because ceramic materials are optically translucent and the strength-limiting flaws are normally located near the valve surface, a laser-scatter method can be used for NDE evaluation of ceramic valves. This paper reviews the progress in the development of this NDE method and its application to inspect silicon-nitride ceramic valves at various stages of manufacturing and bench and engine tests.

Sun, J. G.; Zhang, J. M.; Andrews, M. J.; Tretheway, J. S.; Phillips, N. S .L.; Jensen, J. A.; Nuclear Engineering Division; Univ. of Texas; Caterpillar, Inc.

2008-01-01T23:59:59.000Z

84

The Small Business Tax Relief Program (Georgia) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

The Small Business Tax Relief Program (Georgia) The Small Business Tax Relief Program (Georgia) The Small Business Tax Relief Program (Georgia) < Back Eligibility Agricultural Commercial Construction Developer Fuel Distributor General Public/Consumer Industrial Installer/Contractor Investor-Owned Utility Local Government Municipal/Public Utility Retail Supplier Rural Electric Cooperative Systems Integrator Transportation Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Georgia Program Type Personal Tax Incentives Corporate Tax Incentive The Small Business Tax Relief stipulation allows for faster depreciation on equipment deduction in which businesses can choose to claim the expense in one year as opposed to several years.

85

Blast overpressure relief using air vacated buffer medium  

E-Print Network [OSTI]

Blast waves generated by intense explosions cause damage to structures and human injury. In this thesis, a strategy is investigated for relief of blast overpressure resulting from explosions in air. The strategy is based ...

Avasarala, Srikanti Rupa

2009-01-01T23:59:59.000Z

86

Improve the design of fire emergency relief systems  

SciTech Connect (OSTI)

In recognition of the potential severe consequences of a process vessel rupture under fire exposure, industry codes such as the National Fire Protection Association (NFPA) 30 and the American Petroleum Institute (API) Standard 2000 have been established for the specification of emergency relief systems (ERSs). The intent is to reduce the risk of human injury and asset losses associated with process plant fires. These codes are largely prescriptive in nature. That is, they provide specific details on how to achieve safe design. Prescriptive standards are easy to apply, because they are simplified approaches which generally apply to many (but not all) situations. But they also have limitations, including the tendency to result in, at best, suboptimal (overly conservative) designs, and in some instances potentially unsafe designs. As the fire community moves toward performance-based standards for building protection, perhaps it is time to consider a similar approach for vessel protection in a fire. The design issues addressed in this article include: Use of heat input based on actual fuel burning rate, heat of combustion, and flame emissive power, vs. NFPA 30 and API 2000 heat-input equations; Effect of drainage (from vessel to sump) on fire duration, rather than heat input; Use of risk assessment to determine the relative frequency of fire and process-induced incidents; and design for containment, rather than vessel protection when fire probability is low

Stickles, R.P.; Melhem, G.A.; Eckhardt, D.R.

1995-11-01T23:59:59.000Z

87

Bypass valve and coolant flow controls for optimum temperatures in waste heat recovery systems  

DOE Patents [OSTI]

Implementing an optimized waste heat recovery system includes calculating a temperature and a rate of change in temperature of a heat exchanger of a waste heat recovery system, and predicting a temperature and a rate of change in temperature of a material flowing through a channel of the waste heat recovery system. Upon determining the rate of change in the temperature of the material is predicted to be higher than the rate of change in the temperature of the heat exchanger, the optimized waste heat recovery system calculates a valve position and timing for the channel that is configurable for achieving a rate of material flow that is determined to produce and maintain a defined threshold temperature of the heat exchanger, and actuates the valve according to the calculated valve position and calculated timing.

Meisner, Gregory P

2013-10-08T23:59:59.000Z

88

Force measuring valve assemblies, systems including such valve assemblies and related methods  

DOE Patents [OSTI]

Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

DeWall, Kevin George (Pocatello, ID); Garcia, Humberto Enrique (Idaho Falls, ID); McKellar, Michael George (Idaho Falls, ID)

2012-04-17T23:59:59.000Z

89

Michigan: General Motors Optimizes Engine Valve Technology  

Office of Energy Efficiency and Renewable Energy (EERE)

An EERE-supported effort to increase energy efficiency, while maintaining low emissions, has resulted in new engine valve technology on the 2014 Chevrolet Impala.

90

Install Removable Insulation on Valves and Fittings  

Broader source: Energy.gov [DOE]

This tip sheet on installing removable insulation on valves and fittings provides how-to advice for improving steam systems using low-cost, proven practices and technologies.

91

Michigan: General Motors Optimizes Engine Valve Technology |...  

Energy Savers [EERE]

has resulted in new engine valve technology on the 2014 Chevrolet Impala. EERE's Vehicle Technologies Office supported the research that led to this technical development...

92

Key valves prioritization study. Final report  

SciTech Connect (OSTI)

Key valves, installed in nuclear power plants, are those valves in which a malfunction can result in a shut down, in a reduction in power generation level, or in the extension of planned outages. Over two thousand Licensee Event Reports (LERs) are evaluated to identify the valve failure events which affected nuclear plant availability. Other data reporting systems are used to supplement the information collected for each event. A data base is established comprising 102 key valve failure events that are identified as the principal case of lost plant availability.

Riddington, J.W.

1984-10-01T23:59:59.000Z

93

D0 Silicon Upgrade: Control Dewar Valve Calculations  

SciTech Connect (OSTI)

This engineering note documents the calculations that were done to support the valve size selection for the magnet flow control valve, EVMF in the solenoid control dewar. The size selected was a control valve with a Cv = 0.32.

Rucinski, Russ; /Fermilab

1995-10-20T23:59:59.000Z

94

Pressure Relief Devices for Compressed Hydrogen Vehicle Fuel Containers  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

CSA Standards HPRD1-2009 CSA Standards HPRD1-2009 Temporary Interim Requirement For Pressure Relief Devices For Compressed Hydrogen Vehicle Fuel Containers Published - August 2009 3 5.6 General Hydrogen Service Suitability 5.6.1 General. The purpose of this test is to demonstrate suitability of pressure relief devices in hydrogen service. The pressure relief devices will be selected to be in compliance with Section 5.1 and representative of normal production. NOTE: This series of performance tests may not guarantee that all cases and conditions of service will be validated; it is still incumbent on the designer/builder to carefully screen materials of construction for their intended use. Test Method. The general hydrogen service suitability test sequence will be performed on nine devices.

95

Spray Shadowing For Stress Relief And Mechanical Locking In Thick  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Advanced Materials » Advanced Materials » Spray Shadowing For Stress Relief And Mechanical Locking Spray Shadowing For Stress Relief And Mechanical Locking In Thick Protective Coatings A method for applying a protective coating on an article. Available for thumbnail of Feynman Center (505) 665-9090 Email Spray Shadowing For Stress Relief And Mechanical Locking In Thick Protective Coatings A method for applying a protective coating on an article, comprising the following steps: selecting an article with a surface for applying a coating thickness; creating undercut grooves on the article, where the grooves depend beneath the surface to a bottom portion with the grooves having an upper width on the surface and a lower width on the bottom portion connected by side walls, where at least one of the side walls connects the

96

Overview of the Federal Offshore Royalty Relief Program  

Gasoline and Diesel Fuel Update (EIA)

the Federal Offshore Royalty Relief Program the Federal Offshore Royalty Relief Program This report provides a brief overview of the offshore royalty relief program operated by the Department of the Interior's Minerals Management Service. It describes the basics of revenue collection and royalty payments as well as provisions under which certain oil and natural gas leases are exempt from royalty obligations. Questions or comments on this article may be directed to Erin Mastrangelo at Erin.Mastrangelo@eia.doe.gov or (202)586-6201. In order to explore and develop offshore oil and natural gas resources, the Department of Interior's Minerals Management Service (MMS) awards leases to interested parties through a competitive bidding process. The high bidders must pay a cash bonus bid and

97

Cylinder valve packing nut studies  

SciTech Connect (OSTI)

The design, manufacture, and use of cylinder valve packing nuts have been studied to improve their resistance to failure from stress corrosion cracking. Stress frozen photoelastic models have been analyzed to measure the stress concentrations at observed points of failure. The load effects induced by assembly torque and thermal expansion of stem packing were observed by strain gaging nuts. The effects of finishing operations and heat treatment were studied by the strain gage hole boring and X-ray methods. Modifications of manufacturing and operation practices are reducing the frequency of stress corrosion failures.

Blue, S.C. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

1991-12-31T23:59:59.000Z

98

Requirements for the Valve Train and Technolgies for Enabling...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

for the Valve Train and Technolgies for Enabling HCCI over the Entire Operating Range Requirements for the Valve Train and Technolgies for Enabling HCCI over the Entire Operating...

99

Advanced Materials for Lightweight Valve Train Components | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

for Lightweight Valve Train Components Advanced Materials for Lightweight Valve Train Components Presentation from the U.S. DOE Office of Vehicle Technologies "Mega" Merit Review...

100

Characterization of the mitral valve using accelerated wear testing.  

E-Print Network [OSTI]

??There is a fundamental need for a better kind of long-term testing for artificial heart valves along with a biologically equivalent artificial mitral valve. Accelerated… (more)

Riggan, Courtney N.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

High speed exhaust gas recirculation valve  

DOE Patents [OSTI]

In order to minimize pollutants such as Nox, internal combustion engines typically include an exhaust gas recirculation (EGR) valve that can be used to redirect a portion of exhaust gases to an intake conduit, such as an intake manifold, so that the redirected exhaust gases will be recycled. It is desirable to have an EGR valve with fast-acting capabilities, and it is also desirable to have the EGR valve take up as little space as possible. An exhaust gas recirculation valve is provided that includes an exhaust passage tube, a valve element pivotally mounted within the exhaust passage tube, a linear actuator; and a gear train. The gear train includes a rack gear operatively connected to the linear actuator, and at least one rotatable gear meshing with the rack gear and operatively connected to the valve element to cause rotation of the valve element upon actuation of the linear actuator. The apparatus provides a highly compact package having a high-speed valve actuation capability.

Fensom, Rod (Peterborough, GB); Kidder, David J. (Peterborough, GB)

2005-01-18T23:59:59.000Z

102

Vertical pump with free floating check valve  

DOE Patents [OSTI]

A vertical pump with a bottom discharge having a free floating check valve isposed in the outlet plenum thereof. The free floating check valve comprises a spherical member with a hemispherical cage-like member attached thereto which is capable of allowing forward or reverse flow under appropriate conditions while preventing reverse flow under inappropriate conditions.

Lindsay, Malcolm (O'Hara Township, Allegheny County, PA)

1980-01-01T23:59:59.000Z

103

Minimizing energy losses in control valves  

SciTech Connect (OSTI)

The pulp and paper industry uses massive amounts of energy, but it could reduce its electricity consumption by about 2,000 MW worldwide by simply optimizing the pumping of process liquids. Wasted pumping power can be significantly reduced by sizing pumps and control valves more accurately, and by using new methods of pump and valve selection. Combining the improved control valve's installed flow characteristic with state-of-the-art sizing and simulation programs ensures minimal pressure drop across the control valve without loss of accurate and reliable control in all process conditions. If accurate process condition information is available at the planning stage, even more significant pumping energy savings can be achieved. Moreover, reduced pressure drop across the control valve reduces the likelihood of valve cavitation. This, in turn, reduces the need for noise attenuation, preventing cavitation erosion, and repairing damage. To make the most of the advantages gained by using highly developed control valve sizing and selection programs, closer cooperation between process licensees, process users, and valve manufacturers is also required.

Niemela, I.; Pyotsia, J. (Neles-Jamesbury Oy, Helsinki (Finland))

1994-08-01T23:59:59.000Z

104

A WEAR MODEL FOR DIESEL ENGINE EXHAUST VALVES  

SciTech Connect (OSTI)

The work summarized here comprises the concluding effort of a multi-year project, funded by the U.S. Department of Energy, Office of Vehicle Technologies. It supports the development of a better understanding of advanced diesel engine designs in which enhanced power density, energy efficiency, and emissions control place increasing demands upon the durability of engine materials. Many kinds of metallic alloys are used in engines depending on the operating stresses, temperatures, and chemical environments. Exhaust valves, for example, are subjected to high temperatures and repetitive surface contacts that place demands on durability and frictional characteristics of the materials. Valves must continue to seal the combustion chamber properly for thousands of hours of cyclic engine operation and under varying operating conditions. It was the focus of this effort to understand the wear processes in the valve-seat area and to develop a model for the surface deformation and wear of that important interface. An annotated bibliography is provided to illustrate efforts to understand valve wear and to investigate the factors of engine operation that affect its severity and physical manifestation. The project for which this modeling effort was the final task, involved construction of a high-temperature repetitive impact test system as well as basic tribology studies of the combined processes of mechanical wear plus oxidation at elevated temperatures. Several publications resulted from this work, and are cited in this report. The materials selected for the experimental work were high-performance alloys based on nickel and cobalt. In some cases, engine-tested exhaust valves were made available for wear analysis and to ensure that the modes of surface damage produced in experiments were simulative of service. New, production-grade exhaust valves were also used to prepare test specimens for experimental work along with the other alloy samples. Wear analysis of valves and seats run for hundreds of hours in heavy-duty diesels provided insights into the kinds of complexity that the contact conditions in engines can produce, and suggested the physical basis for the current approach to modeling. The model presented here involves four terms, two representing the valve response and two for its mating seat material. The model's structure assumes that wear that takes place under a complex combination of plastic deformation, tangential shear, and oxidation. Tribolayers form, are removed, and may reform. Layer formation affects the friction forces in the interface, and in turn, the energy available to do work on the materials to cause wear. To provide friction data for the model at various temperatures, sliding contact experiments were conducted from 22 to 850 C in a pin-on-disk apparatus at ORNL. In order to account for the behavior of different materials and engine designs, parameters in all four terms of the model can be adjusted to account for wear-in and incubation periods before the dominant wear processes evolve to their steady-state rates. For example, the deformation rate is assumed to be maximum during the early stages of operation, and then, due to material work-hardening and the increase in nominal contact area (which reduces the load per unit area), decreases to a lower rate at long times. Conversely, the rate of abrasion increases with time or number of cycles due to the build-up of oxides and tribo-layers between contact surfaces. The competition between deformation and abrasion results in complex, non-linear behavior of material loss per cycle of operation. Furthermore, these factors are affected by valve design features, such as the angle of incline of the valve seat. Several modeling scenarios are presented to demonstrate how the wear profile versus number of cycles changes in response to: (a) different relative abrasion rates of the seat and valve materials, (b) the friction coefficient as a function of temperature, (c) the relative deformation contribution of valve and seat materials, and (d) an interruption in the dominant we

Blau, Peter Julian [ORNL

2009-11-01T23:59:59.000Z

105

Whitey SCHe Ball Valves Provide Test Port Isolation  

SciTech Connect (OSTI)

These valves are 1/4 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as normally closed isolation valves for test ports in the SCHe System between the gage root valve and the pressure indicator.

MISKA, C.R.

2000-09-15T23:59:59.000Z

106

Whitey SCHe Ball Valves Provide Test Port Isolation  

SciTech Connect (OSTI)

These valves are 1/4-inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as normally closed isolation valves for test ports in the SCHe System between the gage root valve and the pressure indicator.

MISKA, C.R.

2000-10-19T23:59:59.000Z

107

Pressure compensated flow control valve  

DOE Patents [OSTI]

The invention is an air flow control valve which is capable of maintaining a constant flow at the outlet despite changes in the inlet or outlet pressure. The device consists of a shell assembly with an inlet chamber and outlet chamber separated by a separation plate. The chambers are connected by an orifice. Also located within the inlet chamber is a port controller assembly. The port controller assembly consists of a differential pressure plate and port cap affixed thereon. The cap is able to slide in and out of the orifice separating the inlet and outlet chambers. When the pressure differential is sufficient, the differential pressure plate rises or falls to maintain a constant air flow. Movement of the port controller assembly does not require the use of seals, diaphragms, tight tolerances, bushings, bearings, hinges, guides, or lubricants.

Minteer, Daniel J. (West Richland, WA)

1999-01-01T23:59:59.000Z

108

Torque-Actuated Valves for Microfluidics  

Science Journals Connector (OSTI)

Torque-Actuated Valves for Microfluidics ... While these valves should be widely useful in the field of microfluidics, we demonstrate their use in portable, disposable microfluidic devices. ... Elastomeric polymersespecially poly(dimethylsiloxane) (PDMS)are used widely in microfluidics for several reasons:? (i) ease of fabrication using soft lithography and rapid prototyping;1-3 (ii) ability to incorporate seals, membranes, valves, and switches;4-7 (iii) transparency and compatibility with optical detection;8,9 and (iv) compatibility with water and biological molecules and cells. ...

Douglas B. Weibel; Maarten Kruithof; Scott Potenta; Samuel K. Sia; Andrew Lee; George M. Whitesides

2005-06-15T23:59:59.000Z

109

Method and apparatus for monitoring motor operated valve motor output torque and power at valve seating  

DOE Patents [OSTI]

A method and apparatus are provided for monitoring a motor operated valve during the brief period when the valve seats and the torque switch trips to deenergize the valve motor. The method uses voltage measurements on the load side of a deenergizing switch that opens to deenergize the motor to determine, among other things, final motor rotational speed and the decelerating torque at motor deenergization. 14 figs.

Casada, D.A.

1996-01-16T23:59:59.000Z

110

Method for valve seating control for an electro-hydraulic engine valve  

DOE Patents [OSTI]

Valve lift in an internal combustion engine is controlled by an electro-hydraulic actuation mechanism including a selectively actuable hydraulic feedback circuit.

Sun, Zongxuan (Plymouth, MN)

2011-01-11T23:59:59.000Z

111

Uncertainty Analysis for a Virtual Flow Meter Using an Air-Handling Unit Chilled Water Valve  

SciTech Connect (OSTI)

A virtual water flow meter is developed that uses the chilled water control valve on an air-handling unit as a measurement device. The flow rate of water through the valve is calculated using the differential pressure across the valve and its associated coil, the valve command, and an empirically determined valve characteristic curve. Thus, the probability of error in the measurements is significantly greater than for conventionally manufactured flow meters. In this paper, mathematical models are developed and used to conduct uncertainty analysis for the virtual flow meter, and the results from the virtual meter are compared to measurements made with an ultrasonic flow meter. Theoretical uncertainty analysis shows that the total uncertainty in flow rates from the virtual flow meter is 1.46% with 95% confidence; comparison of virtual flow meter results with measurements from an ultrasonic flow meter yielded anuncertainty of 1.46% with 99% confidence. The comparable results from the theoretical uncertainty analysis and empirical comparison with the ultrasonic flow meter corroborate each other, and tend to validate the approach to computationally estimating uncertainty for virtual sensors introduced in this study.

Song, Li; Wang, Gang; Brambley, Michael R.

2013-04-28T23:59:59.000Z

112

The safety valve and climate policy  

E-Print Network [OSTI]

In discussions of a cap-and-trade system for implementation of Kyoto Protocol-type quantity targets, a "safety valve" was proposed where, by government sales of emissions permits at a fixed price, the marginal cost of the ...

Jacoby, Henry D.; Ellerman, A. Denny.

113

Project Development Specification for Valve Pit Manifold  

SciTech Connect (OSTI)

Establishes the performance, design development, and test requirements for the valve pit manifolds. The system engineering approach was used to develop this document in accordance with the guidelines laid out in the Systems Engineering Management Plan for Project W-314.

MCGREW, D.L.

2000-09-28T23:59:59.000Z

114

Well injection valve with retractable choke  

SciTech Connect (OSTI)

An injection valve is described for use in a well conduit consisting of: a housing having a bore, a valve closure member in the bore moving between open and closed positions, a flow tube telescopically movable in the housing for controlling the movement of the valve closure member, means for biasing the flow tube in a direction for allowing the valve closure member to move to the closed position, an expandable and contractible fluid restriction connected to the flow tube and extending into the bore for moving the flow tube to the open position in response to injection fluid, but allowing the passage of well tools through the valve, the restriction contractible in response to fluid flow, the restriction includes, segments movable into and out of the bore, and biasing means yieldably urging the segments into the bore, a no-go shoulder on the flow tube, and releasable lockout means between the flow tube and the housing for locking the flow tube and valve in the open position.

Pringle, R.E.

1986-07-22T23:59:59.000Z

115

Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing  

SciTech Connect (OSTI)

Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

Wells, Beric E.

2012-12-21T23:59:59.000Z

116

Mechanisms of Oxidation-Enhanced Wear in Diesel Exhaust Valves...  

Broader source: Energy.gov (indexed) [DOE]

May 18-22, 2009 -- Washington D.C. pmp01blau.pdf More Documents & Publications Friction and Wear Reduction in Diesel Engine Valve Trains Materials for Advanced Engine Valve Train...

117

Novel design of a rotary valve using axiomatic design  

E-Print Network [OSTI]

Rotary valves have existed for millennia; and while they have developed tremendously since the first Roman valves, many of the same problems have persisted. The basic problems are caused by the coupling of functional ...

Peliks, Robert Bilgor

2005-01-01T23:59:59.000Z

118

Design and Implementation of Silicon Nitride Valves for Heavy...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

More Documents & Publications Durability of ACERT Engine Components Durability of ACERT Engine Components Advanced Materials for Lightweight Valve Train Components...

119

The pipeline and valve location problem  

Science Journals Connector (OSTI)

This paper, proposes an exact algorithm for the problem of locating a pipeline between two points of a network, as well as a set of safety valves which help control the damage caused by possible spills along the pipeline. A labelling approach is developed to determine simultaneously the optimal pipeline and valve locations, with the objective of optimising an impact measure that depends on the average number of accidents and their cost. Computational experiments on grid and random instances are presented in order to evaluate the algorithm's performance and to compare its results to the solutions provided by sequential approaches. [Received 11 May 2010; Revised 10 October 2010; Accepted 21 November 2010

Gilbert Laporte; Marta M.B. Pascoal

2012-01-01T23:59:59.000Z

120

Modeling Cylinder Valve in Hydrogen Fuel Cell Car  

Science Journals Connector (OSTI)

We develop a fast alternative to a complex finite element analysis (FEA) model of cylinder valve in hydrogen fuel cell car based on support vector machine (SVM). The inputs of model are shape parameters of core and plunger of the valve, and the output ... Keywords: modeling, cylinder valve, SVM, uniform design

Liang Yu; Shengnian Cai; Wang Na

2011-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Design for Control System of Wastegate Valve Actuator in Turbocharger  

Science Journals Connector (OSTI)

This paper has designed a set of control system of waste gate valve actuator in turbocharger, it enables the waste gate valve regulate the exhaust flow before turbo automatically according to the operating condition of engine, so it can lower the pressure ... Keywords: wastegate valve, electronic control, design, test

Liu Xinghua; Yu Lei; Liu Fushui; Wu Wenfeng; Wang Ruwei

2010-12-01T23:59:59.000Z

122

Scoping Study on the Safety Impact of Valve Spacing in Natural Gas Pipelines  

SciTech Connect (OSTI)

The U.S. Department of Transportation's Pipeline and Hazardous Materials Safety Administration (PHMSA) is responsible for ensuring the safe, reliable, and environmentally sound operation of the nation's natural gas and hazardous liquid pipelines. Regulations adopted by PHMSA for gas pipelines are provided in 49 CFR 192, and spacing requirements for valves in gas transmission pipelines are presented in 49 CFR 192.179. The present report describes the findings of a scoping study conducted by Oak Ridge National Laboratory (ORNL) to assist PHMSA in assessing the safety impact of system valve spacing. Calculations of the pressures, temperatures, and flow velocities during a set of representative pipe depressurization transients were carried out using a one-dimensional numerical model with either ideal gas or real gas properties for the fluid. With both ideal gas and real gas properties, the high-consequence area radius for any resulting fire as defined by Stevens in GRI-00/0189 was evaluated as one measure of the pipeline safety. In the real gas case, a model for convective heat transfer from the pipe wall is included to assess the potential for shut-off valve failures due to excessively low temperatures resulting from depressurization cooling of the pipe. A discussion is also provided of some additional factors by which system valve spacing could affect overall pipeline safety. The following conclusions can be drawn from this work: (1) Using an adaptation of the Stephens hazard radius criteria, valve spacing has a negligible influence on natural gas pipeline safety for the pipeline diameter, pressure range, and valve spacings considered in this study. (2) Over the first 30 s of the transient, pipeline pressure has a far greater effect on the hazard radius calculated with the Stephens criteria than any variations in the transient flow decay profile and the average discharge rate. (3) Other factors besides the Stephens criteria, such as the longer burn time for an accidental fire, greater period of danger to emergency personnel, increased unavoidable loss of gas, and possible depressurization cooling of the shut-off valves may also be important when deciding whether a change in the required valve spacing would be beneficial from a safety standpoint. (4) The average normalized discharge rate of {lambda}{sub avg} = 0.33 assumed by Stephens in developing his safety criteria is an excellent conservative value for natural gas discharge at the pressures, valve spacings, and pipe diameter used in this study. This conclusion remains valid even when real rather than ideal gas properties are considered in the analysis. (5) Significant pipe wall cooling effects (T{sub w} < -50 F or 228 K) can extend for a mile or more upstream from the rupture point within 30 s of a break. These conditions are colder than the temperature range specifications for many valve lubricants. The length of the low-temperature zone due to this cooling effect is also essentially independent of the system shut-off valve spacing or the distance between the break and a compressor station. (6) Having more redundant shut-off valves available would reduce the probability that pipe cooling effects could interfere with isolating the broken area following a pipeline rupture accident.

Sulfredge, Charles David [ORNL

2007-07-01T23:59:59.000Z

123

Two-phase flow characteristics in multiple orifice valves  

SciTech Connect (OSTI)

This work presents an experimental investigation on the characteristics of two-phase flow through multiple orifice valve (MOV), including frictional pressure drop and void fraction. Experiments were carried out using an MOV with three different sets of discs with throat thickness-diameter ratios (s/d) of 1.41, 1.66 and 2.21. Tests were run with air and water flow rates ranging between 1.0 and 3.0 m{sup 3}/h, respectively. The two-phase flow patterns established for the experiment were bubbly and slug. Two-phase frictional multipliers, frictional pressure drop and void fraction were analyzed. The determined two-phase multipliers were compared against existing correlations for gas-liquid flows. None of the correlations tested proved capable of predicting the experimental results. The large discrepancy between predicted and measured values points at the role played by valve throat geometry and thickness-diameter ratio in the hydrodynamics of two-phase flow through MOVs. A modification to the constants in the two-phase multiplier equation used for pipe flow fitted the experimental data. A comparison between computed frictional pressure drop, calculated with the modified two-phase multiplier equation and measured pressure drop yielded better agreement, with less than 20% error. (author)

Alimonti, Claudio [Sapienza University of Rome, Department ICMA, Via Eudossiana 18, 00184 Roma (Italy); Falcone, Gioia; Bello, Oladele [The Harold Vance Department of Petroleum Engineering, Texas A and M University, 3116 TAMU, Richardson Building, College Station, TX 77843 (United States)

2010-11-15T23:59:59.000Z

124

Fluid-driven reciprocating apparatus and valving for controlling same  

DOE Patents [OSTI]

A control valve assembly for alternately actuating a pair of fluid-driven free-piston devices by using fluid pressure communication therebetween. Each control valve is switched by a pressure signal depending on the state of its counterpart's piston. The communication logic is arranged to provide overlap of the forward strokes of the pistons, so that at least one of the pair will always be pressurized. Thus, uninterrupted pumping of liquid is made possible from a pair of free-piston pumps. In addition, the speed and frequency of piston stroking is entirely dependent on the mechanical power load applied. In the case of a pair of pumps, this enables liquid delivery at a substantially constant pressure over the full range of flow rates, from zero to maximum flow. One embodiment of the invention utilized two pairs of fluid-driven free-piston devices whereby a bipropellant liquid propulsion system may be operated, so as to provide continuous flow of both fuel and oxidizer liquids when used in rocket applications, for example.

Whitehead, John C. (Davis, CA); Toews, Hans G. (East Aurora, NY)

1993-01-01T23:59:59.000Z

125

Heart Valve Disease James S. Gammie, MD  

E-Print Network [OSTI]

Heart Valve Disease James S. Gammie, MD Professor and Chief Division of Cardiac Surgery University USA Source: CDC #12;#12;CARDIOTHORACIC SURGEON: A SURGEON THAT TREATS HEART AND LUNG DISEASE #12;Valvular Heart Disease: Common and Under-diagnosed 0 2 4 6 8 10 12 14 18 - 44 45 - 54 55 - 64 65 - 74 > 75

Weber, David J.

126

Microfluidic Cell Electroporation Using a Mechanical Valve  

E-Print Network [OSTI]

Microfluidic Cell Electroporation Using a Mechanical Valve Jun Wang, M. Jane Stine, and Chang Lu Center, and Bindley Bioscience Center, Purdue University, West Lafayette, Indiana 47907 A microfluidic of integrating electroporation as a unit operation in large- scale microfluidic systems with the increasing

Lu, Chang

127

Disc valve for sampling erosive process streams  

DOE Patents [OSTI]

This is a patent for a disc-type, four-port sampling valve for service with erosive high temperature process streams. Inserts and liners of ..cap alpha..-silicon carbide respectively, in the faceplates and in the sampling cavities, limit erosion while providing lubricity for a smooth and precise operation. 1 fig.

Mrochek, J.E.; Dinsmore, S.R.; Chandler, E.W.

1984-08-16T23:59:59.000Z

128

A study to determine the most effective actuation valve and water distribution head combination for emergency showers  

E-Print Network [OSTI]

for corrosion and wear. Pressure test to determine strength. (5) Remove shower head and dismantle. Clean scale and rust, from the head inlet and from the slots or orifices in the baffle plate. (6) Reassemble. (7) Open OSBY valve and replace seal..., and orifice sprinkler water distribution heads to determine which valve/head combination produced the greatest flow rate at varying static water pressures. Flow rates were measured at static pressures of 20, 30. 40, 50, and 60 pounds per square inch gauge...

Presswood, James Columbus

1977-01-01T23:59:59.000Z

129

Valve supporting arrangement of an internal combustion engine  

SciTech Connect (OSTI)

A supporting arrangement is described for a valve of an internal combustion engine having a valve stem portion, comprising a rigid member for supporting the stem portion of the valve for axial movement of the valve, a stamped or press-formed upper retainer connected to the upper portion of the valve stem, a lower annular retainer disposed on the rigid member and surrounding the valve stem, and a coil spring compressed between the upper and lower retainers to bias the valve in a direction to close the associated valve opening. The upper retainer has a substantially constant thickness throughout and comprises an annular collar portion having an essentially constant diameter along the length thereof with the diameter at least substantially equal to the inner diameter of the coil spring. The collar portion is coaxially disposed within an upper portion of the coil spring, an annular flange portion extending radially outwardly from the upper end of the collar portion and engaging with the upper end of the coil spring, and means for achieving a spline connection between the central portion of the retainer and the upper portion of the valve stem, and wherein the upper retainer is divided along a diameter into two identical elements which are disposed about the upper portion of the valve stem such that the radial pressure exerted by the coil spring operates to bias the identical elements into their respective positions operative to connect the upper retainer to the valve stem.

Hayashi, Y.

1986-05-27T23:59:59.000Z

130

Technical evaluation: 300 Area steam line valve accident  

SciTech Connect (OSTI)

On June 7, 1993, a journeyman power operator (JPO) was severely burned and later died as a result of the failure of a 6-in. valve that occurred when he attempted to open main steam supply (MSS) valve MSS-25 in the U-3 valve pit. The pit is located northwest of Building 331 in the 300 Area of the Hanford Site. Figure 1-1 shows a layout of the 300 Area steam piping system including the U-3 steam valve pit. Figure 1-2 shows a cutaway view of the approximately 10- by 13- by 16-ft-high valve pit with its various steam valves and connecting piping. Valve MSS-25, an 8-in. valve, is located at the bottom of the pit. The failed 6-in. valve was located at the top of the pit where it branched from the upper portion of the 8-in. line at the 8- by 8- by 6-in. tee and was then ``blanked off`` with a blind flange. The purpose of this technical evaluation was to determine the cause of the accident that led to the failure of the 6-in. valve. The probable cause for the 6-in. valve failure was determined by visual, nondestructive, and destructive examination of the failed valve and by metallurgical analysis of the fractured region of the valve. The cause of the accident was ultimately identified by correlating the observed failure mode to the most probable physical phenomenon. Thermal-hydraulic analyses, component stress analyses, and tests were performed to verify that the probable physical phenomenon could be reasonably expected to produce the failure in the valve that was observed.

Not Available

1993-08-01T23:59:59.000Z

131

Impact of relief accuracy on flood simulations and road network vulnerability analysis  

E-Print Network [OSTI]

1 Impact of relief accuracy on flood simulations and road network vulnerability analysis Jean). Numerical representation of relief (DTM) is a prime necessity in risk simulation, in particular in flood of the flood simulation. On that account, we consider ways to enrich the DTM by integrating relevant

Paris-Sud XI, Université de

132

Economic Congestion Relief Across Multiple Regions Requires Tradable Physical Flow-gate Rights  

E-Print Network [OSTI]

PWP-076 Economic Congestion Relief Across Multiple Regions Requires Tradable Physical Flow.ucei.berkeley.edu/ucei #12;Economic Congestion Relief Across Multiple Regions Requires Tradable Physical Flow-gate Rights- mission use. The North American Electric Reliability Council NERC is in the process of implementing

California at Berkeley. University of

133

EA-0912: Urgent-Relief Acceptance of Foreign Research Reactor Spent Nuclear  

Broader source: Energy.gov (indexed) [DOE]

2: Urgent-Relief Acceptance of Foreign Research Reactor Spent 2: Urgent-Relief Acceptance of Foreign Research Reactor Spent Nuclear Fuel EA-0912: Urgent-Relief Acceptance of Foreign Research Reactor Spent Nuclear Fuel SUMMARY This EA evaluates the environmental impacts of a proposal to accept 409 spent fuel elements from eight foreign research reactors in seven European countries. The spent fuel would be shipped across the ocean in spent fuel transportation casks from the country of origin to one or more United States eastern seaboard ports. PUBLIC COMMENT OPPORTUNITIES None available at this time. DOCUMENTS AVAILABLE FOR DOWNLOAD April 22, 1994 EA-0912: Finding of No Significant Impact Urgent-Relief Acceptance of Foreign Research Reactor Spent Nuclear Fuel April 22, 1994 EA-0912: Final Environmental Assessment Urgent-Relief Acceptance of Foreign Research Reactor Spent Nuclear Fuel

134

Curved butterfly bileaflet prosthetic cardiac valve  

DOE Patents [OSTI]

An annular valve body having a central passageway for the flow of blood therethrough with two curved leaflets each of which is pivotally supported on an accentric positioned axis in the central passageway for moving between a closed position and an open position. The leaflets are curved in a plane normal to the eccentric axis and positioned with the convex side of the leaflets facing each other when the leaflets are in the open position. Various parameters such as the curvature of the leaflets, the location of the eccentric axis, and the maximum opening angle of the leaflets are optimized according to the following performance criteria: maximize the minimum peak velocity through the valve, maximize the net stroke volume, and minimize the mean forward pressure difference, thereby reducing thrombosis and improving the hemodynamic performance.

McQueen, David M. (185 Hillside Ave., Chatham, NJ 07928); Peskin, Charles S. (186 Harrard Dr., Hartsdale, NY 10530)

1991-06-25T23:59:59.000Z

135

Are subsurface safety valves needed in deepwater?  

SciTech Connect (OSTI)

The object of this study was to evaluate SCSSV reliability and identify a preferred configuration for subsea completions in deepwater. A system design consisting of subsea, conventional, dual-bore tree, cluster wells was selected for evaluation. The study examined inherent risks associated with six tubing retrievable SCSSV configurations. Risks were evaluated for personnel and environmental safety, and operational and financial impact of: No SCSSV; Single SCSSV; Dual operating system single SCSSV; Tandem hot/hot (both valves active) SCSSVs without lockout features; Tandem hot/hot SCSSVs with lockout features; Tandem hot/cold (one valve active, the other dormant in open position) SCSSVs with lockout features. A ``fault tree`` identifying events that could lead to deleterious incidents was used to evaluate risks. Costs and consequences associated with potential events were determined using existing industry data, and resulting calculated risks were evaluated. Recommendations were developed and compared to current regulations, and potential regulatory conflicts were identified.

Verret, A.; Hey, C.

1995-11-01T23:59:59.000Z

136

Water cooling of HVDC thyristor valves  

SciTech Connect (OSTI)

It is generally accepted that water is a very effective medium to remove heat losses from any type of equipment. When used for HVDC thyristor valves, the fundamentals of electrolyte conduction and water chemistry need to be considered in the design of the cooling circuit. The characteristics of the materials used, in conjunction with high voltage stresses and circuit configuration, play an important role to assure longevity and corrosion-free performance.

Lips, H.P. (Siemens AG, Erlangen (Germany))

1994-10-01T23:59:59.000Z

137

American Valve: Proposed Penalty (2010-CW-1411) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

American Valve: Proposed Penalty (2010-CW-1411) American Valve: Proposed Penalty (2010-CW-1411) American Valve: Proposed Penalty (2010-CW-1411) September 8, 2010 DOE alleged in a Notice of Proposed Civil Penalty that American Valve, Inc. failed to certify a variety of showerheads as compliant with the applicable water conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable water conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. American Valve: Proposed Penalty (2010-CW-1411) More Documents & Publications American Valve: Order (2010-CW-1411) Afeel: Proposed Penalty (2010-CW-07/1414)

138

Diagnostic for two-mode variable valve activation device  

DOE Patents [OSTI]

A method is provided for diagnosing a multi-mode valve train device which selectively provides high lift and low lift to a combustion valve of an internal combustion engine having a camshaft phaser actuated by an electric motor. The method includes applying a variable electric current to the electric motor to achieve a desired camshaft phaser operational mode and commanding the multi-mode valve train device to a desired valve train device operational mode selected from a high lift mode and a low lift mode. The method also includes monitoring the variable electric current and calculating a first characteristic of the parameter. The method also includes comparing the calculated first characteristic against a predetermined value of the first characteristic measured when the multi-mode valve train device is known to be in the desired valve train device operational mode.

Fedewa, Andrew M

2014-01-07T23:59:59.000Z

139

Novel 4-Way Refrigerant Reversing Valve for Heat Pumps  

SciTech Connect (OSTI)

This project is nearing completion. Since the last progress report (November, 1999), all experimental tests have been completed. Preliminary analysis shows the refrigerant pressure drops through the reversing valve were reduced by an average of about 60{percent}, when compared to traditional reversing valves. Also, the prototype reversing valve reduced the overall coefficient of performance (COP) by an average of only 0.45{percent}.

Darin W. Nutter

2000-02-17T23:59:59.000Z

140

Subsurface safety valve with lock-open system  

SciTech Connect (OSTI)

A well safety valve is described comprising: a housing having a bore therethrough; a valve mounted in the housing to open and close to control the flow through the bore; an operator tube in the housing for opening the valve; means in the housing for moving the operator tube in a first direction to open and hold the valve open; means in the housing for moving the operator tube in a second direction to permit the valve to close; a temporary lockout sleeve in the housing in tandem with the operator tube for temporarily holding the valve open. The operator tube and the lockout sleeve are in end-to-end contact when the lockout sleeve is inoperative and the operator tube is holding the valve open, when the operator tube and the lockout sleeve are moving simultaneously in the housing between operating positions, and when the operator tube is inoperative and the lockout sleeve is holding the valve open; and the operator tube and the lockout sleeve each having means for coupling the operator tube and the lockout sleeve with a lockout tool for moving the operator tube and the lockout sleeve simultaneously when the lockout sleeve is moved from the inoperative to an operative position holding the valve open.

Dickson, R.L.; Smith, R.R.

1986-11-25T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Royalty relief, leasing, exploration may help maintain Cook Inlet production  

SciTech Connect (OSTI)

Cook Inlet production largely held its own in 1995 while Alaska`s overall oil production fell 4%. The Inlet`s seven oil fields produced 15.5 million bbl of oil, or a decline of only 0.6% from 1994`s 15.6 million bbl. Fields and their average production in 1995 compared with 1994 in parentheses, are McArthur River 18,142 b/d (19,427); Middle Ground Shoal 7.753 b/d (7,577); Granite Point 7,069 b/d (6,053); Swanson River 4,738 b/d (4,645); West McArthur River 2,526 b/d (2,522); Trading Bay 1,979 b/d (2,037); and Beaver Creek 362 b/d (383). The paper discusses Unocal`s plans, royalty relief, ARCO`s outlook, sales of Shell, explorations by Marathon, drilling by Stewart, reserves and production, and Cook Inlet leases.

NONE

1996-07-01T23:59:59.000Z

142

Soft robot actuators using energy-efficient valves controlled by electropermanent magnets  

E-Print Network [OSTI]

This paper presents the design, fabrication, and evaluation of a novel type of valve that uses an electropermanent magnet [1]. This valve is then used to build actuators for a soft robot. The developed EPM valves require ...

Marchese, Andrew Dominic

143

E-Print Network 3.0 - air operated valve Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

.5 mm in dia- meter. To create an inlet for air into the pneumatic valve, we used polyethylene tubing... the pneumatic valve, we connected the tubing of the valve ... Source:...

144

Second Peer Review for New MGI Valves for NSTX-U  

E-Print Network [OSTI]

Second Peer Review for New MGI Valves for NSTX-U (Update on Valve Tes · Characterize this valve upto 1000 Torr.L · Describe results in Peer Review (Jan, 2014

Princeton Plasma Physics Laboratory

145

School of Art & Design 3D Printing of Relief Forms onto Ceramic Tiles  

E-Print Network [OSTI]

School of Art & Design 3D Printing of Relief Forms onto Ceramic Tiles Lead: Lharne Shaw 3D printing tile production. It will also assess the feasibility of introducing a 3D slip printing system into both

Evans, Paul

146

Working Families Tax Relief Act of 2004 (released in AEO2005)  

Reports and Publications (EIA)

The Working Families Tax Relief Act of 2004 was signed into law on October 13, 2004. Primarily, the Act reduces taxes for individuals and businesses. At least two provisions relate to energy: Depletion of marginal properties and qualified vehicles.

2005-01-01T23:59:59.000Z

147

Transitional development within shifting spheres of conflict : the Union of Palestinian Medical Relief Committee  

E-Print Network [OSTI]

This thesis examines how an NGO can function and create change within the shifting domains of Palestinian stability and conflict through the case study of the Union of Palestinian Medical Relief Committee (UPMRC). Palestinian ...

Erekat, Dana (Dana M.)

2009-01-01T23:59:59.000Z

148

E-Print Network 3.0 - aortic valve bioprosthesis Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of Biomechanics 34 (2001) 12791289 A nonlinear anisotropic model for porcine aortic heart valves Summary: of porcine aortic valve leaflet has potentially significant effects on...

149

E-Print Network 3.0 - aortic valve insufficiency Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

insufficiency Page: << < 1 2 3 4 5 > >> 1 Interaction between the mitral and aortic heart valve Summary: Interaction between the mitral and aortic heart valve an experimental...

150

E-Print Network 3.0 - aortic valve reconstruction Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

reconstruction Page: << < 1 2 3 4 5 > >> 1 Interaction between the mitral and aortic heart valve Summary: Interaction between the mitral and aortic heart valve an experimental...

151

E-Print Network 3.0 - aortic disc valve Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Hannover Collection: Biology and Medicine 2 Interaction between the mitral and aortic heart valve Summary: Interaction between the mitral and aortic heart valve an experimental...

152

E-Print Network 3.0 - aortic valve prostheses Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

... Source: Collection: Engineering 2 Interaction between the mitral and aortic heart valve Summary: and aortic valve prostheses as well as give directions for improvement...

153

E-Print Network 3.0 - aortic valve morphology Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Toronto Collection: Engineering ; Biology and Medicine 2 Mechanobiology of the Aortic Heart Valve Jonathan T. Butcher1 Summary: Review: Mechanobiology of the Aortic Heart Valve...

154

E-Print Network 3.0 - aortic valve interstitial Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Toronto Collection: Engineering ; Biology and Medicine 2 Mechanobiology of the Aortic Heart Valve Jonathan T. Butcher1 Summary: Review: Mechanobiology of the Aortic Heart Valve...

155

E-Print Network 3.0 - absent pulmonary valve Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Science 3 Insertion of Heart Valves by Catheterization Design Team Summary: treatment (patch) results in degenerated pulmonary heart valves. Open-heart surgery is expensive,...

156

Classification of heart valve condition using acoustic measurements  

SciTech Connect (OSTI)

Prosthetic heart valves and the many great strides in valve design have been responsible for extending the life spans of many people with serious heart conditions. Even though the prosthetic valves are extremely reliable, they are eventually susceptible to long-term fatigue and structural failure effects expected from mechanical devices operating over long periods of time. The purpose of our work is to classify the condition of in vivo Bjork-Shiley Convexo-Concave (BSCC) heart valves by processing acoustic measurements of heart valve sounds. The structural failures of interest for Bscc valves is called single leg separation (SLS). SLS can occur if the outlet strut cracks and separates from the main structure of the valve. We measure acoustic opening and closing sounds (waveforms) using high sensitivity contact microphones on the patient`s thorax. For our analysis, we focus our processing and classification efforts on the opening sounds because they yield direct information about outlet strut condition with minimal distortion caused by energy radiated from the valve disc.

Clark, G. [Lawrence Livermore National Lab., CA (United States)

1994-11-15T23:59:59.000Z

157

Reducing pressure loss of large diameter check valves  

SciTech Connect (OSTI)

Transcend Inc., a consulting firm that specializes in the use of computer simulation to optimize existing equipment and system designs, was approached by Mannesmann Demag AG, Moenchengladbach, Germany to optimize the design of its DRV-B check valve. In one of the first applications of Computational Fluid Dynamics (CFD) technology to valve design, the pressure loss coefficient (K) of the DRV-B valve was lowered to 0.40--0.50 for valve sizes NPS48--NPS12, the lowest possible level for this type of valve. The flow efficiency is three times better than that of the earlier design. As a result, the optimized Mannesmann Demag DRV-B check valve provides a dramatic reduction in operating cost, particularly in transmission service where natural gas is transported over long distances. The reduced pressure loss saves compressor fuel cost. For the optimized valve, the incremental compressor fuel cost is reduced to 1.5-times the capital cost of the valve calculated over a 20-year Life Cycle Cost (LCC) period.

NONE

1997-09-01T23:59:59.000Z

158

Processing of prosthetic heart valve sounds for classification. Revision 1  

SciTech Connect (OSTI)

People with serious heart conditions have had their expected life span extended considerably with the development of the prosthetic heart valve especially with the great strides made in valve design. Even though the designs are extremely reliable, the valves are mechanical and operating continuously over a long period, therefore, structural failures can occur due to fatigue. Measuring heart sounds non-invasively in a noisy environment puts more demands on the signal processing to extract the desired signals from the noise. In this paper the authors discuss acoustical signal processing techniques developed to process noisy heart valve sounds measured by a sensitive, surface contact microphone and used for the eventual classification of the valve.

Candy, J.V.; Jones, H.E.

1994-04-01T23:59:59.000Z

159

Reducing Your Leak Rate Without Repairing Leaks  

E-Print Network [OSTI]

out of a thirteen-minute cycle, which meant they sat idle 76.9 percent of the time. We decided to divide the pneumatic circuit on each machine into two circuits, install an automatic solenoid valve, and program the PLC to shut the air off.... In this case, we decided to install an automatic solenoid valve at each position, and program the PLC to shut the air off to the position when it wasn?t operating. This reduced the leak rate by approximately 1100 scfm from 1500 scfm to 400 scfm. ...

Beals, C.

2005-01-01T23:59:59.000Z

160

Adjustable flow rate controller for polymer solutions  

DOE Patents [OSTI]

An adjustable device for controlling the flow rate of polymer solutions which results in only little shearing of the polymer molecules, said device comprising an inlet manifold, an outlet manifold, a plurality of tubes capable of providing communication between said inlet and outlet manifolds, said tubes each having an internal diameter that is smaller than that of the inlet manifold and large enough to insure that viscosity of the polymer solution passing through each said tube will not be reduced more than about 25 percent, and a valve associated with each tube, said valve being capable of opening or closing communication in that tube between the inlet and outlet manifolds, each said valve when fully open having a diameter that is substantially at least as great as that of the tube with which it is associated.

Jackson, Kenneth M. (Bartlesville, OK)

1981-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Processing of Prosthetic Heart Valve Sounds from Anechoic Tank Measurements  

SciTech Connect (OSTI)

People with serious cardiac problems have had their life span extended with the development of the prosthetic heart valve. However, the valves operate continuously at approximately 39 million cycles per year and are therefore subject to structural failures either by faulty design or material fatigue. The development of a non-invasive technique using an acoustic contact microphone and sophisticated signal processing techniques has been proposed and demonstrated on limited data sets. In this paper we discuss an extension of the techniques to perform the heart valve tests in an anechoic like. Here the objective is to extract a ''pure'' sound or equivalently the acoustical vibration response of the prosthetic valves in a quiet environment. The goal is to demonstrate that there clearly exist differences between values which have a specific mechanical defect known as single leg separation (SLS) and non-defective valves known as intact (INT). We discuss the signal processing and results of anechoic acoustic measurements on 50 prosthetic valves in the tank. Finally, we show the results of the individual runs for each valve, point out any of the meaningful features that could be used to distinguish the SLS from INT and summarize the experiments.

Candy, J V; Meyer, A W

2001-03-20T23:59:59.000Z

162

Analysis of a Third-Generation Princeton Tri-leaflet Mechanical Heart Valve  

E-Print Network [OSTI]

Analysis of a Third-Generation Princeton Tri-leaflet Mechanical Heart Valve Michael Hsu Advisor heart valve · Static analysis of leaflet under uniform pressure of 10 MPa Summer Objectives · Find Heart valve disease · Over 5 million affected · Over 225,000 valve- replacement surgeries performed

Petta, Jason

163

Noninvasive valve monitor using constant magnetic and/or DC electromagnetic field  

DOE Patents [OSTI]

One or more sources of steady magnetic field are carefully located on the outside of a valve body. The constant magnetic field is transmitted into the valve body and valve internals. A magnetic field detector carefully located on the outside of the valve body detects the intensity of the magnetic field at its location. As the position of a valve internal part is changed, there is an alteration in the magnetic field in the valve, and a consequent change in the detected magnetic field. Changes in the detected signal provide an indication of the position and motion of the valve internals.

Casada, D.A.; Haynes, H.D.

1993-08-17T23:59:59.000Z

164

Pressure Transient Analysis of Bottomhole Pressure and Rate Measurements Using System Identification  

E-Print Network [OSTI]

is a zero rate obtained by a quick-closing down hole valve during "drillstem testing". More inaccurate "zero storage coefficient"). In conventional PTA, the step response in the bottom hole pressure resulting from

Van den Hof, Paul

165

Nonlinear springs with applications to flow regulation valves and mechanisms  

E-Print Network [OSTI]

This thesis focuses on the application of nonlinear springs for fluid flow control valves where geometric constraints, or fabrication technologies, limit the use of available solutions. Types of existing nonlinear springs ...

Freeman, David Calvin

2008-01-01T23:59:59.000Z

166

Friction and Wear Reduction in Diesel Engine Valve Trains  

Broader source: Energy.gov (indexed) [DOE]

commercial exhaust valve * Surface damage from 20,000 impacts displays micro-welding, plastic deformation, and transfer. 9 Managed by UT-Battelle for the Department of Energy...

167

Mechanisms of Oxidation-Enhanced Wear in Diesel Exhaust Valves...  

Broader source: Energy.gov (indexed) [DOE]

of wear oxidation microstructures of alloys Fe-, Ni-, Co-alloys h T h i h v Combined plastic deformation, wear, and oxidation on both valve and seat surfaces 6 Managed by...

168

Production-Intent Lost-Motion Variable Valve Actuation Systems  

Broader source: Energy.gov [DOE]

Variable valve actuation with on/off IEGR pre-bump is an enabling technology for HCCI, PCCI, LTC and other advanced combustion techniques, and designs for production-intent equipment have been developed

169

Spin-valve photodiode Ian Appelbaum,a)  

E-Print Network [OSTI]

Spin-valve photodiode Ian Appelbaum,a) D. J. Monsma, K. J. Russell, V. Narayanamurti, and C. M using internal photoemission to generate hot electrons in magnetic multilayer Schottky photodiodes

Russell, Kasey

170

Thermal runaway of valve-regulated lead-acid batteries  

Science Journals Connector (OSTI)

Valve-regulated lead-acid (VRLA) batteries that have aged on a float charge at constant voltage occasionally suffer from thermal runaway. Operating conditions for a VRLA battery have been simulated by changing th...

Junmei Hu; Yonglang Guo; Xuechou Zhou

2006-10-01T23:59:59.000Z

171

Investigation of valve plate in water hydraulic axial piston motor  

Science Journals Connector (OSTI)

This paper has introduced the developments of water hydraulic axial piston equipments. According to the effects of physico-chemical properties of water on water hydraulic components, a novel valve plate for water

Song-Lin Nie Ph.D; Zhuang-Yun Li…

2002-03-01T23:59:59.000Z

172

International Environmental Agreements: Emissions trade, safety valves and escape clauses  

E-Print Network [OSTI]

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 5 Escape clauses versus safety valves 13 6 Review of "standard model" of IEAs 14 6.1 Dynamics The effect of emissions trade on IEA participation 17 7.1 Ex ante heterogenous countries

Karp, Larry S.

173

Electric actuation of a surface controlled subsea safety valve  

E-Print Network [OSTI]

to the conversion of many components from hydraulic operation to electric. Therefore, it is the purpose of this report to detail and propose an engineering solution to the electrical conversion of a surface controlled subsea safety valve (SCSSV). Preliminary...

Bartlett, Timothy Joseph

2013-02-22T23:59:59.000Z

174

Energy Savings Potential of Process Control Valve Replacement  

E-Print Network [OSTI]

candidates for savings. A feasibility study of retrofitting a pipeline flow control system, currently operating with a constant speed pump and differential producing, modulating control valve, with a variable speed drive is presented. This case study...

Holzenthal, L. Jr.

175

Signal processing of Shiley heart valve data for fracture detection  

SciTech Connect (OSTI)

Given digital acoustic data emanating from the heart sounds of the beating heart measured from laboratory sheep with implanted Bjoerk-Shiley Convexo-Concave heart valves, it is possible to detect and extract the opening and closing heart beats from the data. Once extracted, spectral or other information can then obtained from the heartbeats and passed on to feature extraction algorithms, neutral networks, or pattern recognizers so that the valve condition, either fractured or intact, may be determined.

Mullenhoff, C.

1993-04-01T23:59:59.000Z

176

Signal processing of Shiley heart valve data for fracture detection  

SciTech Connect (OSTI)

Given digital acoustic data emanating from the heart sounds of the beating heart measured from laboratory sheep with implanted Bjoerk-Shiley Convexo-Concave heart valves, it is possible to detect and extract the opening and closing heart beats from the data. Once extracted, spectral or other information can then obtained from the heartbeats and passed on to feature extraction algorithms, neural networks, or pattern recognizers so that the valve condition, either fractured or intact, may be determined.

Mullenhoff, C.

1993-09-01T23:59:59.000Z

177

Sizing safety valve vent pipes for saturated steam  

SciTech Connect (OSTI)

A generalized procedure based on pressure and entropy as independent variables is used to calculate choked flow conditions at the valve orifice, valve pipe outlet and vent pipe outlet. At the third location, the results are independent of whether flow in the vent pipe is supersonic or subsonic. An integral method is used to calculate the vent pipe length required to choke the flow. 16 refs.

Brandmaier, H.E.

1982-01-01T23:59:59.000Z

178

DEPARTMENT OF ENERGY OFFICE OF GENERAL COUNSEL INTERPRETATION REGARDING EXEMPTION RELIEF PURSUANT TO  

Broader source: Energy.gov (indexed) [DOE]

INTERPRETATION REGARDING EXEMPTION RELIEF PURSUANT TO 10 C.F.R. PART 820, PROCEDURAL RULES FOR DOE NUCLEAR ACTIVITIES, SUBPART E, EXEMPTION RELIEF, AND NON-COMPLIANT "DOCUMENTED SAFETY ANALYSES" SUBJECT TO 10 C.F.R. PART 830, NUCLEAR SAFETY MANAGEMENT, SUBPART B, SAFETY BASIS REQUIREMENTS Subpart D to 10 C.F.R Part 820 provides that the Department of Energy's (DOE) General Counsel (GC) shall be responsible for interpreting the DOE Nuclear Safety Requirements. Pursuant to that authority, the GC here responds to two questions received regarding contractor compliance with safety basis requirements: 1. Does 10 C.F.R. Part 820, Procedural Rules for DOE Nuclear Activities, allow

179

detonation rate  

Science Journals Connector (OSTI)

detonation rate, detonation velocity, velocity of detonation, V.O.D., detonating velocity, rate of detonation, detonating rate ? Detonationsgeschwindigkeit f

2014-08-01T23:59:59.000Z

180

Valves - current operating experience of slurry valves (block and letdown) in coal liquefaction processes. Third quarter report  

SciTech Connect (OSTI)

This paper summarizes the recent letdown and block valve experience in the liquefaction pilot plants. Also included is a brief description of the research and development activities on valves which are conducted in supporting laboratories. The purpose of the summary is to concentrate on critical component problems common to all liquefaction plants, to avoid duplication of efforts, and to help provide timely solutions to the valve problems. The main source of information used in this paper is the Minutes of the Critical Component and Materials Meeting which is sponsored by the Office of Coal Processing, Fossil Energy, Department of Energy. Other sources of information such as the technical progress reports are also included based on availability and relevance to topics covered in this paper. It is intended that this report will be followed by updates as pertinent information concerning valves becomes available. In the subsequent sections of this paper a brief outline of past valve studies is given as background material followed by a summary of the most recent valve operating experience at the liquefaction plants.

NONE

1996-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Engine including hydraulically actuated valvetrain and method of valve overlap control  

DOE Patents [OSTI]

An exhaust valve control method may include displacing an exhaust valve in communication with the combustion chamber of an engine to an open position using a hydraulic exhaust valve actuation system and returning the exhaust valve to a closed position using the hydraulic exhaust valve actuation assembly. During closing, the exhaust valve may be displaced for a first duration from the open position to an intermediate closing position at a first velocity by operating the hydraulic exhaust valve actuation assembly in a first mode. The exhaust valve may be displaced for a second duration greater than the first duration from the intermediate closing position to a fully closed position at a second velocity at least eighty percent less than the first velocity by operating the hydraulic exhaust valve actuation assembly in a second mode.

Cowgill, Joel (White Lake, MI)

2012-05-08T23:59:59.000Z

182

The price elasticity of charitable giving: does the form of tax relief matter?  

Science Journals Connector (OSTI)

We use a survey-based approach to compare the effects of alternative forms of tax relief on donations—a tax rebate for the donor and a matched payment ... more responsive to a match than to a rebate. The differen...

Kimberley Scharf; Sarah Smith

2014-02-01T23:59:59.000Z

183

ABSTRACT. The stress-relief cracking (SRC) susceptibility of single-pass welds  

E-Print Network [OSTI]

steel, HCM2S, has been evaluated and compared to 2.25Cr-1Mo steel using Gleeble thermal simulation and pressure vessels for chemical and fossil power plants. Many components in these power plants oper- ate techniques. HCM2S was found to be more susceptible to stress-relief cracking than 2.25Cr-1Mo steel. Simulated

DuPont, John N.

184

GSATodAy|FebruAry2013 Miocene rejuvenation of topographic relief in  

E-Print Network [OSTI]

of topographic decay in post-orogenic mountain ranges (Davis, 1889; Hack, 1960; Bishop, 2007). Central largely controlled by the variable erodibility of rock units (Hack, 1960; Matmon et al., 2003). The second posits that modern relief is a product of recent rejuvenation (Hack, 1982); however, whether the process

Bohnenstiehl, Delwayne

185

System and method for controlling hydraulic pressure in electro-hydraulic valve actuation systems  

DOE Patents [OSTI]

A control system for an engine includes a first lift control module and a second lift control module. The first lift control module increases lift of M valves of the engine to a predetermined valve lift during a period before disabling or re-enabling N valves of the engine. The second lift control module decreases the lift of the M valves to a desired valve lift during a period after enabling or re-enabling the N valves of the engine, wherein N and M are integers greater than or equal to one.

Brennan, Daniel G; Marriott, Craig D; Cowgill, Joel; Wiles, Matthew A; Patton, Kenneth James

2014-09-23T23:59:59.000Z

186

Classification of prosthetic heart valve sounds. A parametric approach  

SciTech Connect (OSTI)

People with heart problems have had their lives extended considerably with the development of the prosthetic heart valve. Great strides have been made in the development of the valves through the use of improved materials as well as efficient mechanical designs. However, since the valves operate continuously over a long period, structural failures can occur-even though they are relatively uncommon. Here the development of techniques to classify the valve either as having intact struts or as having a separated strut, commonly called single leg separation, is discussed. In this paper the signal processing techniques employed to extract the required signals/parameters are briefly reviewed and then it is shown how they can be used to simulate a synthetic heart valve database for eventual Monte Carlo testing. Next, the optimal classifier is developed under assumed conditions and its performance is compared to that of an adpative-type classifier implemented with a probabilistic neural network. Finally, the adaptive classifier is applied to a data set and its performance is analyzed. Based on synthetic data it is shown that excellent performance of the classifiers can be achieved implying a potentially robust solution to this classification problem. 21 refs., 11 figs., 1 tab.

Candy, J.V.; Jones, H.E. [Univ. of California, Livermore, CA (United States)]|[Lawrence Livermore National Lab., CA (United States)

1995-06-01T23:59:59.000Z

187

Measuring while drilling apparatus mud pressure signal valve  

SciTech Connect (OSTI)

This patent describes a measurement while drilling system for borehole drilling having a downhole instrument connectable in a drill string of a rotary drilling rig including apparatus to sense geological and geophysical parameters and a valve apparatus to pulse modulate drilling fluid flowing in the drill string. A surface apparatus is connected to a drilling fluid flow conductor for extracting intelligence carrying information from the modulated drilling fluid. An improved valve apparatus is described comprising: (a) a drilling fluid flow pulse modulating pressure pulse valve member longitudinally, movably mounted in a body member and movable from a retracted position substantially removed from the drilling fluid flow and an extended position disposed at least partially within the drilling fluid flow thereby temporarily restricting drilling fluid flow within the drill string; and (b) the pulse valve member is a tubular member having a lower end portion displaceable from the body member into the drilling fluid and an upper end portion with opposed fluid pressure force areas thereon being in fluid communication with the drilling fluid flow such that forces due to the drilling fluid acting on the pressure pulse valve member are balanced in a longitudinal direction.

Peppers, J.M.; Shaikh, F.A.

1986-12-09T23:59:59.000Z

188

Drive piston assembly for a valve actuator assembly  

DOE Patents [OSTI]

A drive piston assembly is provided that is operable to selectively open a poppet valve. The drive piston assembly includes a cartridge defining a generally stepped bore. A drive piston is movable within the generally stepped bore and a boost sleeve is coaxially disposed with respect to the drive piston. A main fluid chamber is at least partially defined by the generally stepped bore, drive piston, and boost sleeve. First and second feedback chambers are at least partially defined by the drive piston and each are disposed at opposite ends of the drive piston. At least one of the drive piston and the boost sleeve is sufficiently configured to move within the generally stepped bore in response to fluid pressure within the main fluid chamber to selectively open the poppet valve. A valve actuator assembly and engine are also provided incorporating the disclosed drive piston assembly.

Sun, Zongxuan (Troy, MI)

2010-02-23T23:59:59.000Z

189

An iterative algorithm for model-based predictive control of an electro-pneumatic valve actuator  

Science Journals Connector (OSTI)

The benefits of utilizing camless valve actuations for internal combustion engines are primarily due to their ability of significantly improving engine performance. There are mainly three kinds of camless valve actuators: electro-magnetic, electro-hydraulic, ...

Guoming G. Zhu; Jia Ma; Harold Schock

2009-06-01T23:59:59.000Z

190

E-Print Network 3.0 - aortic valve stenosis Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

valve is the most common cause for aortic stenosis. Risk... without such risk factors (Peltier et al., 2003). Regardless of the etiology of the aortic valve stenosis... with an ......

191

E-Print Network 3.0 - aortic valve area Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

<< < 1 2 3 4 5 > >> 1 A Computational Model of Aging and Calcification in the Aortic Heart Valve Summary: fluid velocity and aortic valve opening area (AVA) at each age. These...

192

E-Print Network 3.0 - aortic heart valve Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

heart valve Search Powered by Explorit Topic List Advanced Search Sample search results for: aortic heart valve Page: << < 1 2 3 4 5 > >> 1 Non-Invasive Evaluation of Opening and...

193

E-Print Network 3.0 - aortic valve regurgitation Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

regurgitation Page: << < 1 2 3 4 5 > >> 1 Interaction between the mitral and aortic heart valve Summary: or regurgitation. In 2001, of all valve diseases in the left ventricle,...

194

E-Print Network 3.0 - aortic valve thickening Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

<< < 1 2 3 4 5 > >> 1 A Computational Model of Aging and Calcification in the Aortic Heart Valve Summary: of a normal, healthy valve thicken and become less extensible over...

195

Effect of respiration on Doppler parameters of normal tricuspid porcine bioprosthetic valves  

Science Journals Connector (OSTI)

The Doppler indexes of tricuspid porcine bioprosthetic valves were evaluated in twelve patients without clinical and two-dimensional echocardiographic evidence of valve dysfunction. Peak and mean pressure grad...

Bernard Cosyns; Guy van Camp; Alain Friart…

1995-03-01T23:59:59.000Z

196

Development and introduction of wire for engine valve springs in VAZ  

Science Journals Connector (OSTI)

Valve springs (inner and outer) are critical parts of a car and therefore should meet stringent requirements with respect to their endurance and elastic properties. Results of work on introducing wire for valv...

V. G. Azizbekyan; R. M. Gaizullin; M. D. Kopyl…

1996-11-01T23:59:59.000Z

197

Water Consumption from Freeze Protection Valves for Solar Water Heating Systems  

SciTech Connect (OSTI)

Conference paper regarding research in the use of freeze protection valves for solar domestic water heating systems in cold climates.

Burch, J.; Salasovich, J.

2005-12-01T23:59:59.000Z

198

Investigation of valve failure problems in LWR power plants  

SciTech Connect (OSTI)

An analysis of component failures from information in the computerized Nuclear Safety Information Center (NSIC) data bank shows that for both PWR and BWR plants the component category most responsible for approximately 19.3% of light water reactor (LWR) power plant shutdowns. This investigation by Burns and Roe, Inc. shows that the greatest cause of shutdowns in LWRs due to valve failures is leakage from valve stem packing. Both BWR plants and PWR plants have stem leakage problems (BWRs, 21% and PWRs, 34%).

None

1980-04-01T23:59:59.000Z

199

Wear and wear mechanism simulation of heavy-duty engine intake valve and seat inserts  

SciTech Connect (OSTI)

A silicon-chromium alloy frequently used for heavy-duty diesel engine intake valves was tested against eight different insert materials with a valve seat wear simulator. Wear resistance of these combinations was ranked. For each test, the valve seat temperature was controlled at approximately 510 C, the number of cycles was 864,000 (or 24 h), and the test load was 17,640 N. The combination of the silicon-chromium valve against a cast iron insert produced in the least valve seat wear, whereas a cobalt-base alloy insert produced the highest valve seat wear. In the overall valve seat recession ranking, however, the combination of the silicon-chromium valve and an iron-base chromium-nickel alloy insert had the least total seat recession, whereas the silicon-chromium valve against cobalt-base alloy, cast iron, and nickel-base alloy inserts had significant seat recession. Hardness and microstructure compatibility of valve and insert materials are believed to be significant factors in reducing valve and insert wear. The test results indicate that the mechanisms of valve seat and insert wear are a complex combination of adhesion and plastic deformation. Adhesion was confirmed by material transfer, while plastic deformation was verified by shear strain (or radial flow) and abrasion. The oxide films formed during testing also played a significant role. The prevented direct metal-to-metal contact and reduced the coefficient of friction on seat surfaces, thereby reducing adhesive and deformation-controlled wear.

Wang, Y.S.; Narasimhan, S.; Larson, J.M.; Schaefer, S.K. [Eaton Corp., Marshall, MI (United States). Engine Components Operations] [Eaton Corp., Marshall, MI (United States). Engine Components Operations

1998-02-01T23:59:59.000Z

200

Worcester 1 Inch Solenoid Actuated Gas Operated VPS System Ball Valve  

SciTech Connect (OSTI)

1 inch Gas-operated full-pod ball valve incorporates a solenoid and limit switches as integral park of the actuator. The valve is normally open and fails safe to the closed position. The associated valve position switch is class GS.

MISKA, C.R.

2000-11-13T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Strategic planning for disaster relief logistics: lessons from supply chain management  

Science Journals Connector (OSTI)

Management of disaster relief logistics requires different techniques at different levels. We identify four stages: 1 strategic planning which concerns high level decisions such as supplier selection and confirmation of communication protocols; 2 preparedness which concerns decisions regarding the amount and location of relief supplies to be stored; 3 pre-event response which concerns decisions during those occasions when an approaching disaster, such as a hurricane, has been detected; 4 post-event response which concerns what needs to be done immediately after a disaster has occurred. In this article, we concentrate on the strategic planning stage and build an integrated logistics model based on elements of supply chain management theory. This model provides specific recommendations to practitioners and identifies important areas to be researched. We also point out the applicable techniques at each of the other stages and cite relevant literature.

Nezih Altay; Sameer Prasad; Jayavel Sounderpandian

2009-01-01T23:59:59.000Z

202

INTERPRETATION REGARDING EXEMPTION RELIEF UNDER 10 C.F.R. PART 820, SUBPART E, EXEMPTION RELIEF, AND NON-COMPLIANT ‘DOCUMENTED SAFETY ANALYSES’ SUBJECT TO 10 C.F.R. PART 830, NUCLEAR SAFETY MANAGEMENT, SUBPART B, SAFETY BASIS REQUIREMENTS  

Broader source: Energy.gov [DOE]

The following document is the Office of General Counsel (GC) interpretation regarding exemption relief pursuant to 10 C.F.R. Part 820, Procedural Rules for DOE Nuclear Activities, Subpart E,...

203

Mobile medical disaster relief technology : enhancing communication, medical logistics, data creation, and crisis mapping for vulnerable communities  

E-Print Network [OSTI]

This thesis explores the field of disaster relief and recovery, and the application of emerging technologies that are both used by, and use the data generated by communities affected by natural disaster. This thesis analyzes ...

Intrator, Kira (Kira Rachel)

2012-01-01T23:59:59.000Z

204

Sensations: a fabric of natural alcoves to provide relief from city life and stimulate the five senses  

E-Print Network [OSTI]

Cities have always been, and will likely always be, hectic. With every new technological advance this characteristic becomes amplified, and today city life offers little relief from cell phone chatter, honking car horns, ...

Brown, Megan (Megan Francesca)

2008-01-01T23:59:59.000Z

205

The 1,000 dollar home : a scalable business model to build disaster relief dwellings and upgrade slums  

E-Print Network [OSTI]

This thesis proposes a new model for the private markets to build disaster relief dwellings or to upgrade degraded neighborhoods of very low income communities. The study offers a way to empower the dwellers of very poor ...

Cañzio, Luis (Del Cañzio)

2006-01-01T23:59:59.000Z

206

Optimization of nonbinary slanted surface-relief gratings as high-efficiency broadband couplers for light guides  

Science Journals Connector (OSTI)

We propose and investigate the use of slanted surface-relief gratings with nonbinary profiles as high-efficiency broadband couplers for light guides. First, a Chandezon-method-based...

Bai, Benfeng; Laukkanen, Janne; Kuittinen, Markku; Siitonen, Samuli

2010-01-01T23:59:59.000Z

207

Recrystallization and modification of the stainless-steel surface relief under photonic heat load in powerful plasma discharges  

SciTech Connect (OSTI)

Targets made of ITER-grade 316L(N)-IG stainless steel and Russian-grade 12Cr18Ni10Ti stainless steel with a close composition were exposed at the QSPA-T plasma gun to plasma photonic radiation pulses simulating conditions of disruption mitigation in ITER. After a large number of pulses, modification of the stainless-steel surface was observed, such as the formation of a wavy structure, irregular roughness, and cracks on the target surface. X-ray and optic microscopic analyses of targets revealed changes in the orientation and dimensions of crystallites (grains) over a depth of up to 20 ?m for 316L(N)-IG stainless steel after 200 pulses and up to 40 ?m for 12Cr18Ni10Ti stainless steel after 50 pulses, which is significantly larger than the depth of the layer melted in one pulse (?10 ?m). In a series of 200 tests of ITER-grade 316L(N)-IG ITER stainless steel, a linear increase in the height of irregularity (roughness) with increasing number of pulses at a rate of up to ?1 ?m per pulse was observed. No alteration in the chemical composition of the stainless-steel surface in the series of tests was revealed. A model is developed that describes the formation of wavy irregularities on the melted metal surface with allowance for the nonlinear stage of instability of the melted layer with a vapor/plasma flow above it. A decisive factor in this case is the viscous flow of the melted metal from the troughs to tops of the wavy structure. The model predicts saturation of the growth of the wavy structure when its amplitude becomes comparable with its wavelength. Approaches to describing the observed stochastic relief and roughness of the stainless-steel surface formed in the series of tests are considered. The recurrence of the melting-solidification process in which mechanisms of the hill growth compete with the spreading of the material from the hills can result in the formation of a stochastic relief.

Budaev, V. P., E-mail: budaev@mail.ru; Martynenko, Yu. V. [National Research Centre Kurchatov Institute (Russian Federation)] [National Research Centre Kurchatov Institute (Russian Federation); Khimchenko, L. N. [Project Center ITER (Russian Federation)] [Project Center ITER (Russian Federation); Zhitlukhin, A. M.; Klimov, N. S. [Troitsk Institute for Innovation and Fusion Research (Russian Federation)] [Troitsk Institute for Innovation and Fusion Research (Russian Federation); Pitts, R. A. [ITER Organization (France)] [ITER Organization (France); Linke, J. [EURATOM Association, Forschungszentrum Jülich GmbH (Germany)] [EURATOM Association, Forschungszentrum Jülich GmbH (Germany); Bazylev, B. [IHM, Karlsruhe Institute of Technology (Germany)] [IHM, Karlsruhe Institute of Technology (Germany); Belova, N. E.; Karpov, A. V. [National Research Centre Kurchatov Institute (Russian Federation)] [National Research Centre Kurchatov Institute (Russian Federation); Kovalenko, D. V.; Podkovyrov, V. L.; Yaroshevskaya, A. D. [Troitsk Institute for Innovation and Fusion Research (Russian Federation)] [Troitsk Institute for Innovation and Fusion Research (Russian Federation)

2013-11-15T23:59:59.000Z

208

Pumps, pipes and valves: The heart of a system  

SciTech Connect (OSTI)

This is a guide to suppliers of pumps, pipes and valves for construction or repair of hazardous materials. The article contains a compilation of the suppliers/manufacturers and how to contact them, the corrosion resistance of the component, whether double-secondary containment is available, and the material used to construct the component.

NONE

1996-05-01T23:59:59.000Z

209

Covered Product Category: Pre-Rinse Spray Valves  

Broader source: Energy.gov [DOE]

The Federal Energy Management Program (FEMP) provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including pre-rinse spray valves, which are a FEMP-designated product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

210

ON CONDITION MONITORING OF EXHAUST VALVES IN MARINE DIESEL ENGINES  

E-Print Network [OSTI]

is to seal during the compression stroke, thereby providing maximum #12; combustion pressure for maximum seat and thereby provide scavenge (from scavenge air system) of the polluted air in the cylinder and fresh air intake for the following compression and combustion. Valve burn­through, or leakage, can

Mosegaard, Klaus

211

Feasibility study of using optical moir?? interferometry technique for fine-grain surface relief in heritage recording.  

E-Print Network [OSTI]

, there is a need for more efficient tools for recording relief contours of irregular surfaces. Ancient heritage sites lack regularity due to erosion and non-standardization of construction. 19 This requires great time and expense to create accurate..., there is a need for more efficient tools for recording relief contours of irregular surfaces. Ancient heritage sites lack regularity due to erosion and non-standardization of construction. 19 This requires great time and expense to create accurate...

Al-Ratrout, Samer Abdulmunim

2005-11-01T23:59:59.000Z

212

Combustion engine with fuel injection system, and a spray valve for such an engine  

SciTech Connect (OSTI)

This paper describes a fuel system for a combustion engine have a cylinder with an air inlet passage. It comprises: a fuel spray valve having a fuel injection nozzle for spraying fuel into the cylinder air inlet passage and having a fuel spray valve passage leading to the nozzle, means for mounting the fuel spray valve to position the nozzle to open into the cylinder air inlet passage adjacent the cylinder, a fuel pump for providing fuel under pressure to the fuel spray valve passage to be sprayed from the fuel spray valve nozzle, and a fuel heating device connectable to an electrical power supply and disposed adjacent to the valve to be energized for heating the fuel to enhance finer spraying thereof by the fuel spray valve nozzle, the fuel heating device comprising means defining a spiral fuel flow path of selected length connected to and coaxial with the fuel spray valve passage to dispose the selected length of fuel flow path closely adjacent to the fuel spray valve passage, and a fuel heating element comprising a thermistor of a ceramic material of positive temperature coefficient of resistivity arranged to heat the selected length of the spiral fuel flow path to transfer heat to the fuel flowing in the spiral fuel flow path throughout the selected length of the spiral fuel flow path to substantially heat the fuel at a location closely adjacent to the fuel spray valve passage to enhance vaporizing of fuel being sprayed from the valve nozzle.

Wechem, G.V.; Beunk, G.; Van Den Elst, F.; Gerson, P.M.

1991-10-08T23:59:59.000Z

213

Nondestructive evaluation of silicon-nitride ceramic valves from engine duration test.  

SciTech Connect (OSTI)

In this study, we investigated impact and wear damage in silicon-nitride ceramic valves that were subjected to an engine duration test in a natural-gas engine. A high-speed automated laser-scattering system was developed for the nondestructive evaluation (NDE) of 10 SN235P silicon-nitride valves. The NDE system scans the entire valve surface and generates a two-dimensional scattering image that is used to identify location, size and relative severity of subsurface damage in the valves. NED imaging data were obtained at before and at 100 and 500 hours of the engine duration test. The NDE data were analyzed and compared with surface photomicrographs. Wear damage was found in the impact surface of all valves, expecially for exhaust valves. However, the NDE examination did not detect subsurface damage such as cracks or spalls in these engine-tested valves.

Sun, J. G.; Trethewey, J. S.; Vanderspiegle, N. N.; Jensen, J. A.; Nuclear Engineering Division; Caterpillar, Inc.

2008-01-01T23:59:59.000Z

214

Rate Schedules  

Broader source: Energy.gov [DOE]

One of the major responsibilities of Southeastern is to design, formulate, and justify rate schedules. Repayment studies prepared by the agency determine revenue requirements and appropriate rate...

215

Rates - WAPA-137 Rate Order  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

WAPA-137 Rate Order WAPA-137 Rate Order 2009 CRSP Management Center Customer Rates Second Step Presentation from the June 25, 2009, Customer Meeting Handout Materials from the June 25, 2009, Customer Meeting Customer Comment Letters ATEA CREDA Farmington ITCA AMPUA Rate Adjustment Information The second step of WAPA-137 SLCA/IP Firm Power, CRSP Transmission and Ancillary Services rate adjustment. FERC Approval of Rate Order No. WAPA-137 Notice Of Filing for Rate Order No. WAPA-137 Published Final FRN for Rate Order No. WAPA-137 Letter to Customers regarding the published Notice of Extension of Public Process for Rate Order No. WAPA-137 Published Extension of Public Process for Rate Order No. WAPA-137 FRN Follow-up Public Information and Comment Forum Flier WAPA-137 Customer Meetings and Rate Adjustment Schedule

216

Removable check valve for use in a nuclear reactor  

DOE Patents [OSTI]

A removable check valve for interconnecting the discharge duct of a pump and an inlet coolant duct of a reactor core in a pool-type nuclear reactor. A manifold assembly is provided having an outer periphery affixed to and in fluid communication with the discharge duct of the pump and has an inner periphery having at least one opening therethrough. A housing containing a check valve is located within the inner periphery of the manifold. The upper end of the housing has an opening in alignment with the opening in the manifold assembly, and seals are provided above and below the openings. The lower end of the housing is adapted for fluid communication with the inlet duct of the reactor core.

Dunn, Charlton (Calabasas, CA); Gutzmann, Edward A. (Simi Valley, CA)

1988-01-01T23:59:59.000Z

217

Technology Reinvestment Program/Advanced ``Zero Emission'' Control Valve (Phase II)  

SciTech Connect (OSTI)

The objectives of this effort are to determine, develop and demonstrate the feasibility of significantly reducing the cost and expanding the applications for a family of Advanced Zero Emissions Control Valves that meets the fugitive emissions requirements of the 1990 Amendments to the Clean Air Act. This program is a direct technology spin-off from the valve technology that is critical to the US Navy's Nuclear Powered Fleet. These zero emissions valves will allow the Hydrocarbon and Chemical Processing Industries, etc., to maintain their competitiveness and still meet environmental and safety requirements. Phase 2 is directed at refining the basic technologies developed during Phase 1 so that they can be more readily selected and utilized by the target market. In addition to various necessary certifications, the project will develop a full featured digital controller with ``smart valve'' growth capability, expanding valve sizes/applications and identifying valve materials to permit applications in severe operational environments.

J. Napoleon

1998-12-01T23:59:59.000Z

218

The selection and maintenance of valves for the control of fugitive emissions  

SciTech Connect (OSTI)

The pulp and paper industry has long needed valves that (a) have extremely low stem leakage when they are new and (b) need little or no maintenance to retain that low leakage over their service life. The EPA fugitive emission regulations provide additional impetus for the pulp and paper industry to buy such valves and for the valve and packing industry to produce such valves. Even if particular operations are not covered by the fugitive emissions regulations, it is--and always has been--in a mill's best interest to have valves whose stems don't leak and need little or no maintenance to prevent that leakage. The paper gives some recommendations on how to meet that objective: selection the right packing materials; apply the right amount of stress to the packing; install the packing correctly; and use rotary valves where practical.

Dresch, C. (NIBCO Inc., Elkhart, IN (United States))

1994-08-01T23:59:59.000Z

219

Raman Microscopy and Mapping as a Probe for Photodegradation in Surface Relief Gratings Recorded on Layer-by-Layer Films of Congo Red/Polyelectrolyte  

Science Journals Connector (OSTI)

Raman microscopy, mapping, and surface-enhanced Raman scattering techniques have been applied to investigate the degradation of Congo Red (CR) in a surface relief grating (SRG)...

Constantino, C J L; Aroca, R F; He, J -A; Zucolotto, V; Li, L; Oliveira, O N; Kumar, J; Tripathy, S K

2002-01-01T23:59:59.000Z

220

Failure Modes and Causes for Swing and Lift Type Check Valves  

Office of Scientific and Technical Information (OSTI)

Prior to the recent work performed by Oak Ridge National Laboratory (ORNL) relative to nuclear industry check valve performance, no information was readily available regarding the...

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

E-Print Network 3.0 - aortic valve sclerosis Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

aortic valve disease... 21 ... Source: Simmons, Craig A. - Department of Mechanical and Industrial Engineering, University of Toronto Collection: Engineering ; Biology and...

222

NUPRO process vent/MCO check valve - prevent backflow from process vent into MCO  

SciTech Connect (OSTI)

NUPRO process vent/MCO check valve - prevent backflow from process vent into MCO CGI-SNF-D-30-3-P4-040.

VAN KATWIJK, C.

1999-07-01T23:59:59.000Z

223

E-Print Network 3.0 - aortic valve surgery Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Medicine ; Chemistry 2 A Computational Model of Aging and Calcification in the Aortic Heart Valve Summary: A Computational Model of Aging and Calcification in the Aortic Heart...

224

E-Print Network 3.0 - aortic valve calcium Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

; Biology and Medicine 2 Inhibition of aortic wall calcification in bioprosthetic heart valves by ethanol pretreatment: Biochemical and Summary: Inhibition of aortic wall...

225

E-Print Network 3.0 - active infective valve Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: Non-invasive assessment of leaflet deformation and mechanical properties in heart valve tissue... -invasive assessment of leaflet deformation and mechanical properties...

226

E-Print Network 3.0 - ahmed valve implantation Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Collection: Engineering ; Materials Science ; Biology and Medicine 3 Insertion of Heart Valves by Catheterization Design Team Summary: procedure for surgeons to implant heart...

227

E-Print Network 3.0 - autologous pulmonary valves Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ecole Polytechnique, Centre de mathmatiques Collection: Mathematics 2 Autologous Heart Valve Tissue Engineering CIP-DATA LIBRARY TECHNISCHE UNIVERSITEIT EINDHOVEN Summary:...

228

E-Print Network 3.0 - aortic valve implantation Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and Medicine ; Chemistry 3 Inhibition of aortic wall calcification in bioprosthetic heart valves by ethanol pretreatment: Biochemical and Summary: , Comparison of...

229

Means for positively seating a piezoceramic element in a piezoelectric valve during inlet gas injection  

DOE Patents [OSTI]

A piezoelectric valve in a gas delivery system includes a piezoceramic element bonded to a valve seal and disposed over a valve seat, and retained in position by an O-ring and a retainer; an insulating ball normally biased by a preload spring against the piezoceramic element; an inlet gas port positioned such that upon admission of inlet gas into the valve, the piezoceramic element is positively seated. The inlet gas port is located only on the side of the piezoceramic element opposite the seal. 3 figs.

Wright, K.E.

1994-08-23T23:59:59.000Z

230

Means for positively seating a piezoceramic element in a piezoelectric valve during inlet gas injection  

DOE Patents [OSTI]

A piezoelectric valve in a gas delivery system includes a piezoceramic element bonded to a valve seal and disposed over a valve seat, and retained in position by an O-ring and a retainer; an insulating ball normally biased by a preload spring against the piezoceramic element; an inlet gas port positioned such that upon admission of inlet gas into the valve, the piezoceramic element is positively seated. The inlet gas port is located only on the side of the piezoceramic element opposite the seal.

Wright, Kenneth E. (Yardley, PA)

1994-01-01T23:59:59.000Z

231

Rate schedule  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Firm Power Service Provided by Rate/Charges Firm Power Service Provided by Rate/Charges Rate/Charges Effective Through (or until superceded) Firm Sales (SLIP-F9) Composite Rate SLIP 29.62 mills/kWh 9/30/2015 Demand Charge SLIP $5.18/kW-month 9/30/2015 Energy Charge SLIP 12.19 mills/kWh 9/30/2015 Cost Recovery Charge (CRC) SLIP 0 mills/kWh 9/30/2015 Transmission Service Provided by Current Rates effective10/12 - 9/15 (or until superceded) Rate Schedule Effective Through Firm Point-to-Point Transmission (SP-PTP7) CRSP $1.14 per kW-month $13.69/kW-year $0.00156/kW-hour $0.04/kW-day $0.26/kW-week 10/1/2008-9/30/2015 Network Integration Transmission (SP-NW3) CRSP see rate schedule 10/1/2008-9/30/2015 Non-Firm Point-to-Point Transmission (SP-NFT6) CRSP see rate schedule 10/1/2008-9/30/2015 Ancillary Services Provided by Rate Rate Schedule

232

Flexible, reusable fiberglass insulation tailored to fit valves, heat exchangers  

SciTech Connect (OSTI)

About 120,000 bbl/day of crude oil are refined into gasoline at the Marathon Petroleum refinery in Robinson, IL. Built in the early part of the century, the Robinson refinery has been continually updated and modernized in response to improving technology. To control heat loss on some of the unusually shaped and previously uninsulated process equipment, Marathon engineering personnel initiated a program to systematically evaluate and insulate these pieces of equipment. Primarily, over 500 valves and heat exchanger heads were losing heat which had been estimated to cost hundreds of thousands of dollars per year. The plant performed on-site evaluations of several types of removable insulation covers. The primary differences and deciding factors were in construction detail - particularly in the fasteners. Marathon chose lace-up fastening insulation covers because plant evaluation found them to be the best. Also the manufacturer agreed to provide tailor-made covers for all of the valves and heat exchanger heads. Service from the manufacturer through an insulation contractor located in Robinson was also a plus. The local contractor, working in conjunction with the manufacturer, conducted an in-plant survey that confirmed the already mentioned heat loss cost in the $100,000s range. It was also determined that an equipment temperature somewhere between 150 and 200/sup 0/F was the lowest temperature at which to economically install insulation. Marathon has been pleased with the performance of the insulation covers which reduce heat loss and, as an incidental benefit, provide personnel safety from hot surfaces. An important benefit has been the removability and reusability of the insulation, particularly advantageous on valves and heat exchangers the require frequent access.

Gockenbach, L.G.; Singleton, D.; Toy, D.A.

1986-06-01T23:59:59.000Z

233

Deepwater royalty relief product of 3 1/2 year U.S. political effort  

SciTech Connect (OSTI)

Against the backdrop of more than 20 years of increasingly stringent environmental regulation, ever-expanding exploration and development moratoria on the Outer Continental Shelf (OCS), and reductions in producer tax incentives, oil and natural gas exploration companies active in deep waters of the Gulf of Mexico recently won a significant legislative victory. On Nov. 28, 1995, President Clinton signed into law S.395, the Alaska Power Administration Sale Act. Title 3 of S.395 embodies the Outer Continental Shelf Deep Water Royalty Relief Act. This landmark legislation provides substantial incentives for oil and natural gas production in the gulf of Mexico by temporarily eliminating royalties on certain deepwater leases. It is the first direct incentive for oil and gas production enacted at the federal level in many years. This paper reviews the elements used to arrive at this successful legislation including the congressional leadership. It describes debates, cabinet level discussions, and use of parlimentary procedures.

Davis, R.E. [Stuntz and Davis, Washington, DC (United States); Neff, S. [Senate Energy and Natural Resources Committee, Washington, DC (United States)

1996-04-01T23:59:59.000Z

234

Where Did All the Money Go? Congress approved the Troubled Asset Relief Program (TARP) to jump start the credit  

E-Print Network [OSTI]

Where Did All the Money Go? Congress approved the Troubled Asset Relief Program (TARP) to jump forward that unfortunately remains vague. Inexplicably, the TARP II money did not come with a mandate to use the money to increase lending. Now, covenants come with the distribution of the remaining TARP

Ahmad, Sajjad

235

IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 17, NO. 1, FEBRUARY 2002 159 Economic Congestion Relief Across Multiple  

E-Print Network [OSTI]

IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 17, NO. 1, FEBRUARY 2002 159 Economic Congestion Relief, and Andrew M. Ross Abstract--This paper is concerned with market-based protocols for relieving congestion caused by transactions outside the control area in which the congestion occurred. One approach, proposed

236

Date: Jan 2014 Scope of the Water Mission: The Stafford Disaster Relief and Emergency Assistance Act, authorizes the  

E-Print Network [OSTI]

Date: Jan 2014 Scope of the Water Mission: The Stafford Disaster Relief and Emergency Assistance, the Federated States of Micronesia, and the Republic of the Marshall Islands. The contract also includes 2013 and will expire on 31 March 2014. The contract has 4 option years which may be exercised on 1

US Army Corps of Engineers

237

Adaptive Robust Control of Programmable Valves with Manufacturer Supplied Flow Mapping Only  

E-Print Network [OSTI]

and final tracking accuracy. In addition, real-time adaptation is used to reduce the degree of modelling-in and meter-out orifices [2], [3], [4] through valves number 1,2 and 4,5; and ii) enabling the precise control is the significant modelling error. The cartridge valves are of fast response and low cost but low accuracy

Yao, Bin

238

System for detecting operating errors in a variable valve timing engine using pressure sensors  

DOE Patents [OSTI]

A method and control module includes a pressure sensor data comparison module that compares measured pressure volume signal segments to ideal pressure volume segments. A valve actuation hardware remedy module performs a hardware remedy in response to comparing the measured pressure volume signal segments to the ideal pressure volume segments when a valve actuation hardware failure is detected.

Wiles, Matthew A.; Marriot, Craig D

2013-07-02T23:59:59.000Z

239

Potential Viability of a Fast-Acting Micro-Solenoid Valve for Pulsed Detonation Fuel Injection  

E-Print Network [OSTI]

current (A) k spring constant (kg/s2 ) Ll flux leakage inductance (H) L(, x) non-linear coil inductance (H-load conditions, indicating the ability of spring- return micro-valves to function reliably at high frequencies) m mass of movable valve core and spring assembly (kg) n integer number of successive (positive

Texas at Arlington, University of

240

MOTION PLANNING CONTROL OF THE AIRPATH OF AN S.I. ENGINE WITH VALVE  

E-Print Network [OSTI]

MOTION PLANNING CONTROL OF THE AIRPATH OF AN S.I. ENGINE WITH VALVE TIMING ACTUATORS T. Leroy , J, France Abstract: We address the control of the airpath of a turbocharged S.I. engine equipped with Variable Valve Timing actuators (VVT). Compared to standard configurations, the engine does not possess any

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Journal of Biomechanics 34 (2001) 12791289 A nonlinear anisotropic model for porcine aortic heart valves  

E-Print Network [OSTI]

Journal of Biomechanics 34 (2001) 1279­1289 A nonlinear anisotropic model for porcine aortic heart finite element model for porcine heart valves. The model is based on the uniaxial experimental data of porcine aortic heart valve leaflet and the properties of nonlinear composite material. A finite element

Luo, Xiaoyu

242

Microfluidic very large scale integration (mVLSI) with integrated micromechanical valves{  

E-Print Network [OSTI]

Microfluidic very large scale integration (mVLSI) with integrated micromechanical valves{ Ismail40258k Microfluidic chips with a high density of control elements are required to improve device and accessible high-density microfluidic chips, we have fabricated a monolithic PDMS valve architecture

Quake, Stephen R.

243

ESTIMATION OF EXHAUST MANIFOLD PRESSURE IN TURBOCHARGED GASOLINE ENGINES WITH VARIABLE VALVE TIMING  

E-Print Network [OSTI]

ESTIMATION OF EXHAUST MANIFOLD PRESSURE IN TURBOCHARGED GASOLINE ENGINES WITH VARIABLE VALVE TIMING in turbocharged gasoline engines with variable valve timing requires knowledge of exhaust mani- fold pressure, Pe control systems for gasoline engines rely heavily on feedforward air-fuel ratio (A/F) control to meet

Grizzle, Jessy W.

244

The superconducting spin valve and triplet superconductivity I.A. Garifullin a,n  

E-Print Network [OSTI]

The superconducting spin valve and triplet superconductivity I.A. Garifullin a,n , P.V. Leksin s t r a c t A review of our recent results on the spin valve effect is presented. We have used coefficient DF and the exchange splitting I of the conduction band in the F layer [1]. For pure Fe the value

Fominov, Yakov

245

Proceedings of the 2nd symposium on valves for coal conversion and utilization  

SciTech Connect (OSTI)

The 2nd symposium on valves for coal conversion and utilization was held October 15 to 17, 1980. It was sponsored by the US Department of Energy, Morgantown Energy Technology Center, in cooperation with the Valve Manufacturers Association. Seventeen papers have been entered individually into EDB and ERA. (LTN)

Maxfield, D.A. (ed.)

1981-01-01T23:59:59.000Z

246

Memory effect and temperature behavior in spin valves with and without antiferromagnetic subsystems  

E-Print Network [OSTI]

Memory effect and temperature behavior in spin valves with and without antiferromagnetic subsystems Temperature behavior and memory effect in standard spin valves SV and SVs with synthetic antiferromagnetic Co/Ru/Co SV-SAF subsystems have been studied. SV-SAFs show much better temperature stability. Memory effect

Xiao, John Q.

247

Hydraulically actuated fuel injector including a pilot operated spool valve assembly and hydraulic system using same  

DOE Patents [OSTI]

The present invention relates to hydraulic systems including hydraulically actuated fuel injectors that have a pilot operated spool valve assembly. One class of hydraulically actuated fuel injectors includes a solenoid driven pilot valve that controls the initiation of the injection event. However, during cold start conditions, hydraulic fluid, typically engine lubricating oil, is particularly viscous and is often difficult to displace through the relatively small drain path that is defined past the pilot valve member. Because the spool valve typically responds slower than expected during cold start due to the difficulty in displacing the relatively viscous oil, accurate start of injection timing can be difficult to achieve. There also exists a greater difficulty in reaching the higher end of the cold operating speed range. Therefore, the present invention utilizes a fluid evacuation valve to aid in displacement of the relatively viscous oil during cold start conditions.

Shafer, Scott F. (Morton, IL)

2002-01-01T23:59:59.000Z

248

Interdiffusion in CoFeCu multilayers and its application to spin-valve structures for data storage  

E-Print Network [OSTI]

, the interdiffusion coefficients for all layers in the spin valve have to be determined. For diffusion drivenInterdiffusion in CoFeÃ?Cu multilayers and its application to spin-valve structures for data storage, Pennsylvania 15213-3890 Received 13 February 2003; accepted 30 April 2003 Spin-valve structures might

Laughlin, David E.

249

IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, VOL. 15, NO. 6, NOVEMBER 2007 1065 Robust Optimal Design of Unstable Valves  

E-Print Network [OSTI]

and outer radii of the valve chamber; and 3) the nonmetering orifice momentum flux coefficient which Design of Unstable Valves QingHui Yuan, Member, IEEE, and Perry Y. Li, Member, IEEE Abstract--This paper of electrohydraulic valves. Currently, limitations of solenoid actua- tors have prevented single stage

Li, Perry Y.

250

Performance characteristics of a turbo expander substituted for expansion valve on air-conditioner  

Science Journals Connector (OSTI)

An experimental study is conducted on a small turbo expander which could be applied to the expansion process in place of expansion valves in refrigerator or air-conditioner to improve the cycle efficiency by recovering energy from the throttling process. The operating gas is \\{HFC134a\\} and the maximum cooling capacity of experiment apparatus is 32.7 kW. Four different turbo expanders are tested to find the performance characteristics of the turbo expander when they operate at a low partial admission rate. The partial admission rate is 1.70% or 2.37, and expanders are operated in the supersonic flow. In the experiment, pressure and temperature are measured at 10 different locations in the experimental apparatus. In addition to these measurements, output power at the turbo expander is measured through a generator installed on a rotor shaft with the rotational speed. Performance data of the turbo expander are obtained at many part load operations by adjusting the output power of the generator. A maximum of 15.8% total-to-static efficiency is obtained when the pressure ratio and the partial admission ratio are 2.37 and 1.70%, respectively. Experimental results show that the optimal velocity ratio decreases when the pressure ratio is decreased, and peak efficiencies, which are obtained at locally maximized efficiency depending on the operating condition, vary linearly against the subcooling temperature or the pressure ratio.

Soo-Yong Cho; Chong-Hyun Cho; Chaesil Kim

2008-01-01T23:59:59.000Z

251

Performance characteristics of a turbo expander substituted for expansion valve on air-conditioner  

SciTech Connect (OSTI)

An experimental study is conducted on a small turbo expander which could be applied to the expansion process in place of expansion valves in refrigerator or air-conditioner to improve the cycle efficiency by recovering energy from the throttling process. The operating gas is HFC134a and the maximum cooling capacity of experiment apparatus is 32.7 kW. Four different turbo expanders are tested to find the performance characteristics of the turbo expander when they operate at a low partial admission rate. The partial admission rate is 1.70% or 2.37, and expanders are operated in the supersonic flow. In the experiment, pressure and temperature are measured at 10 different locations in the experimental apparatus. In addition to these measurements, output power at the turbo expander is measured through a generator installed on a rotor shaft with the rotational speed. Performance data of the turbo expander are obtained at many part load operations by adjusting the output power of the generator. A maximum of 15.8% total-to-static efficiency is obtained when the pressure ratio and the partial admission ratio are 2.37 and 1.70%, respectively. Experimental results show that the optimal velocity ratio decreases when the pressure ratio is decreased, and peak efficiencies, which are obtained at locally maximized efficiency depending on the operating condition, vary linearly against the subcooling temperature or the pressure ratio. (author)

Cho, Soo-Yong [Department of Mechanical and Aerospace Engineering (ReCAPT), Gyeongsang National University, 900 Gajoa-dong, Jinju 660-701 (Korea); Cho, Chong-Hyun [School of Mechanical and Aerospace Engineering, Gyeongsang National University, 900 Gajoa-dong, Jinju 660-701 (Korea); Kim, Chaesil [Department of Mechanical Engineering, Changwon National University, 9 Sarim-dong, Changwon 641-773 (Korea)

2008-09-15T23:59:59.000Z

252

Rapid 3D printing of anatomically accurate and mechanically heterogeneous aortic valve hydrogel scaffolds  

Science Journals Connector (OSTI)

The aortic valve exhibits complex three-dimensional (3D) anatomy and heterogeneity essential for the long-term efficient biomechanical function. These are, however, challenging to mimic in de novo engineered living tissue valve strategies. We present a novel simultaneous 3D printing/photocrosslinking technique for rapidly engineering complex, heterogeneous aortic valve scaffolds. Native anatomic and axisymmetric aortic valve geometries (root wall and tri-leaflets) with 12–22 mm inner diameters (ID) were 3D printed with poly-ethylene glycol-diacrylate (PEG-DA) hydrogels (700 or 8000 MW) supplemented with alginate. 3D printing geometric accuracy was quantified and compared using Micro-CT. Porcine aortic valve interstitial cells (PAVIC) seeded scaffolds were cultured for up to 21 days. Results showed that blended PEG-DA scaffolds could achieve over tenfold range in elastic modulus (5.3±0.9 to 74.6±1.5 kPa). 3D printing times for valve conduits with mechanically contrasting hydrogels were optimized to 14 to 45 min, increasing linearly with conduit diameter. Larger printed valves had greater shape fidelity (93.3±2.6, 85.1±2.0 and 73.3±5.2% for 22, 17 and 12 mm ID porcine valves; 89.1±4.0, 84.1±5.6 and 66.6±5.2% for simplified valves). PAVIC seeded scaffolds maintained near 100% viability over 21 days. These results demonstrate that 3D hydrogel printing with controlled photocrosslinking can rapidly fabricate anatomical heterogeneous valve conduits that support cell engraftment.

L A Hockaday; K H Kang; N W Colangelo; P Y C Cheung; B Duan; E Malone; J Wu; L N Girardi; L J Bonassar; H Lipson; C C Chu; J T Butcher

2012-01-01T23:59:59.000Z

253

Valve assembly for use with high temperature and high pressure fluids  

DOE Patents [OSTI]

The valve assembly for use with high temperature and high pressure fluids has inner and outer spaced shells and a valve actuator support of inner and outer spaced members which are connected at their end portions to the inner and outer shells, respectively, to extend substantially normal to the longitudinal axis of the inner shell. A layer of resilient heat insulating material covers the outer surfaces of the inner shell and the inner actuator support member and is of a thickness to only occupy part of the spaces between the inner and outer shells and inner and outer actuator support members. The remaining portion of the space between the inner and outer shells and the space between the inner and outer members is substantially filled with a body of castable, rigid refractory material. A movable valve member is disposed in the inner shell. A valve actuator assembly is supported in the valve actuator support to extend into the inner shell for connection with the movable valve member for movement of the movable valve member to positions from a fully open to a fully closed position to control flow of fluid through the inner shell. An anchor mneans is disposed adjacent opposite sides of the axis of the valve actuator support and attached to the inner shell so that relative radial movement between the inner and outer shell is permitted by the layer of resilient heat insulating material and relative longitudinal movement of the inner shell to the outer shell is permitted in opposite directions from the anchor means to thereby maintain the functional integrity of the movable valve member by providing an area of the inner shell surrounding the movable valve member longitdinally stationary, but at the same time allowing radial movement.

De Feo, Angelo (Totowa, NY)

1982-01-01T23:59:59.000Z

254

Fluoroscopically Guided Feeding Tube Insertion for Relief of Postoperative Gastrointestinal Anastomotic Obstruction and Leakage  

SciTech Connect (OSTI)

Purpose. To evaluate the feasibility and effectiveness of feeding tube insertion and enteral feeding for the treatment of postoperative gastrointestinal anastomotic obstruction and leakage. Materials and Methods. From June 1999 to June 2002, thirty-four cases of postoperative gastrointestinal anastomotic obstruction and leakage after surgery for gastric carcinoma were treated by insertion of a feeding tube under fluoroscopic guidance. Twenty-one patients were male and 13 were female. The patients' ages ranged from 39 to 74 years (mean age: 61 years). All the patients experienced vomiting, and 15 patients had anastomotic site or duodenal stump leakage. We evaluated the feasibility of feeding tube insertion for enteral feeding to improve the obstruction and facilitate leakage site closure, and the patients' nutritional benefit was also evaluated by checking the serum albumin level between pre- and post-enteral feeding via the feeding tube.Results. Thirty-two patients (94%) were successfully managed by feeding tube insertion, but the remaining two were not managed, and this was due to severe angulations at the anastomotic site. The procedure times for feeding tube insertion ranged from 15 to 60 minutes (mean time: 45 minutes). Twenty-eight patients experienced symptomatic relief of gastrointestinal obstruction, and they were able to resume a normal regular diet after feeding tube removal. Three patients underwent stent insertion due to recurrent symptoms, and one patient underwent jejunostomy feeding due to the presence of a persistent leakage site. Eleven patients achieved leakage site closure after enteral feeding via a feeding tube. The serum albumin level was significant, increased from pre-enteral feeding (2.65 {+-} 0.37 g/dL) to the post-enteral feeding (3.64 {+-} 0.58 g/dL) via the feeding tube (p < 0.001). The duration of follow-up ranged from one to 53 months (mean: 23 months). Conclusion. The insertion of a feeding tube for enteral feeding under fluoroscopic guidance is safe, and it provides effective relief from gastrointestinal anastomotic site obstruction and leakage after gastric surgery. Moreover, our findings indicate that feeding tube insertion for enteral feeding may be used as the primary procedure to treat postoperative anastomotic obstruction and leakage.

Han, Young-Min [Chonbuk National University Medical School and Hospital, Department of Radiology (Korea, Republic of)], E-mail: ymhan@chonbuk.ac.kr; Kim, Chan-Young; Yang, Doo-Hyun [Chonbuk National University Medical School and Hospital, Department of Surgery (Korea, Republic of); Kwak, Hyo-Sung; Jin, Gong-Yong [Chonbuk National University Medical School and Hospital, Department of Radiology (Korea, Republic of)

2006-06-15T23:59:59.000Z

255

Coal slurry letdown valve-concept test phase. Final report  

SciTech Connect (OSTI)

The results of the concept test phase of a novel pressure letdown device indicate usefulness of the concept. The device, using staged letdown, was designed to minimize erosion damage by minimizing slurry velocities through the pressure restrictions. Tests were performed on air, steam/water and a coal slurry with a flashing component. Two valve sizes were used. Based on the results of these tests, the following conclusions were drawn: (1) the basic operating principle of designing for a constant velocity through the orifice restrictions is correct; (2) multiphase pressure letdown can be modeled; (3) temperature profiles are predictable; and (4) erosion in three-phase flow is a complex phenomenon. Recommendations for further work on the device include: (1) development of a controllable device; (2) correlation of further test data; and (3) study of flow regimes where erosion is minimized. 9 refs., 48 figs., 6 tabs.

Collins, E.R. Jr.; Suitor, J.W.

1984-01-01T23:59:59.000Z

256

Environmental Assessment of Urgent-Relief Acceptance of Foreign Research Reactor Spent Nuclear Fuel  

SciTech Connect (OSTI)

The Department of Energy has completed the Environmental Assessment (EA) of Urgent-Relief Acceptance of Foreign Research Reactor Spent Nuclear Fuel and issued a Finding of No Significant Impact (FONSI) for the proposed action. The EA and FONSI are enclosed for your information. The Department has decided to accept a limited number of spent nuclear fuel elements (409 elements) containing uranium that was enriched in the United States from eight research reactors in Austria, Denmark, Germany, Greece, the Netherlands, Sweden, and Switzerland. This action is necessary to maintain the viability of a major US nuclear weapons nonproliferation program to limit or eliminate the use of highly enriched uranium in civil programs. The purpose of the EA is to maintain the cooperation of the foreign research reactor operators with the nonproliferation program while a more extensive Environmental Impact Statement (EIS) is prepared on a proposed broader policy involving the acceptance of up to 15,000 foreign research reactor spent fuel elements over a 10 to 15 year period. Based on an evaluation of transport by commercial container liner or chartered vessel, five eastern seaboard ports, and truck and train modes of transporting the spent fuel overland to the Savannah River Sits, the Department has concluded that no significant impact would result from any combination of port and made of transport. In addition, no significant impacts were found from interim storage of spent fuel at the Savannah River Site.

Not Available

1994-04-01T23:59:59.000Z

257

Fail Save Shut Off Valve for Filtering Systems Employing Candle Filters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Fail Save Shut Off Fail Save Shut Off Valve for Filtering Systems Employing Candle Filters Opportunity The Department of Energy's National Energy Technology Laboratory (NETL) is seeking licensing partners interested in implementing United States Patent Number 6,981,516 entitled "Fail save shut off valve for filtering systems employing candle filters." Disclosed in this patent is a novel fail save shut off valve system that allows fluid flow during normal operational conditions, but prevents the flow of fluids in the event of system failure upstream that causes over- pressurization. It is particularly well suited for use in conjunction with hot gas filtering systems, which utilize ceramic candle filters. Used in such a hot gas system, the fail save valve stops the flow

258

Closed-loop, variable-valve-timing control of a controlled-auto-ignition engine  

E-Print Network [OSTI]

The objective of this study was to develop a closed-loop controller for use on a Controlled-Auto- Ignition (CAI) / Spark-Ignition (SI) mixed mode engine equipped with a variable-valve-timing (VVT) mechanism. The controller ...

Matthews, Jeffrey A., 1970-

2004-01-01T23:59:59.000Z

259

HIGH-FREQUENCY MAGNETOCAPACITANCE EFFECT IN ORGANIC SPIN VALVE WITH A  

E-Print Network [OSTI]

HIGH-FREQUENCY MAGNETOCAPACITANCE EFFECT IN ORGANIC SPIN VALVE WITH A 3,4,9,10-PERYLENE Institute of Atomic and Molecular Sciences Academia Sinica, 10617 Taipei, Taiwan *mtlin@phys.ntu

Lin, Minn-Tsong

260

Classification of heart valve single leg separations from acoustic clinical measurements  

SciTech Connect (OSTI)

Our system classifies the condition (intact or single leg separated) of in vivo Bjork-Shiley Convexo-Concave (BSCC) heart valves by processing acoustic measurements of clinical heart valve opening sounds. We use spectral features as inputs to a two-stage classifier, which first classifies individual heart beats, then classifies valves. Performance is measured by probability of detection and probability of false alarm, and by confidence intervals on the probability of correct classification. The novelty of the work lies in the application of advanced techniques to real heart valve data, and extensions of published algorithms that enhance their applicability. We show that even when given a very small number of training samples, the classifier can achieve a probability of correct classification of 100%.

Clark, G.A.; Bowman, B.C.; Boruta, N.; Thomas, G.H.; Jones, H.E.; Buhl, M.R.

1994-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Estimation and Control of Diesel Engine Processes Utilizing Variable Intake Valve Actuation  

Broader source: Energy.gov [DOE]

Air handling system model for multi-cylinder variable geometry turbocharged diesel engine with cooled EGR and flexible intake valve actuation developed to capture dynamic effects of gas exchange actuators

262

Rankine cycle condenser pressure control using an energy conversion device bypass valve  

DOE Patents [OSTI]

The disclosure provides a waste heat recovery system and method in which pressure in a Rankine cycle (RC) system of the WHR system is regulated by diverting working fluid from entering an inlet of an energy conversion device of the RC system. In the system, an inlet of a controllable bypass valve is fluidly coupled to a working fluid path upstream of an energy conversion device of the RC system, and an outlet of the bypass valve is fluidly coupled to the working fluid path upstream of the condenser of the RC system such that working fluid passing through the bypass valve bypasses the energy conversion device and increases the pressure in a condenser. A controller determines the temperature and pressure of the working fluid and controls the bypass valve to regulate pressure in the condenser.

Ernst, Timothy C; Nelson, Christopher R; Zigan, James A

2014-04-01T23:59:59.000Z

263

E-Print Network 3.0 - aortic valve substitution Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

<< < 1 2 3 4 5 > >> 1 A Computational Model of Aging and Calcification in the Aortic Heart Valve Summary: A Computational Model of Aging and Calcification in the Aortic Heart...

264

E-Print Network 3.0 - aortic valve calcification Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

<< < 1 2 3 4 5 > >> 1 A Computational Model of Aging and Calcification in the Aortic Heart Valve Summary: A Computational Model of Aging and Calcification in the Aortic Heart...

265

E-Print Network 3.0 - aortic valve replacement Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

<< < 1 2 3 4 5 > >> 1 A Computational Model of Aging and Calcification in the Aortic Heart Valve Summary: A Computational Model of Aging and Calcification in the Aortic Heart...

266

E-Print Network 3.0 - aortic valve endocarditis Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

are aortic valve disease, present in 12 to 30 percent of cases, and congenital heart disease... in detection of IE.24 TEE is especially important for patients with aortic...

267

A PDMS membrane microvalve with one-dimensional line valve seat for robust microfluidics  

Science Journals Connector (OSTI)

We have developed a monolithic polydimethylsiloxane (PDMS) membrane microvalve with an isotropically etched valve seat for robust microfluidics. In order to avoid bonding or sticking of the PDMS membrane to the valve seat during the bonding process, the valve seat was wet-etched to be a one-dimensional line instead of a plane. The simple wet-etching technique allowed for the fabrication of an anti-bonding architecture in a scalable manner, and it intrinsically prevented contact between the PDMS membrane and valve seat when no external force was applied (i.e., normally open). This approach enables the permanent device assembly so that the microfluidic chip can be operable in a wide range of fluid pressures (e.g., over 200 kPa) without any leakage and sticking problems.

Chin-Sung Park; Kyu-Youn Hwang; Wonjong Jung; Kak Namkoong; Wonseok Chung; Joon-Ho Kim; Nam Huh

2014-01-01T23:59:59.000Z

268

Percutaneous aortic valve replacement in a re-animated postmortem heart  

E-Print Network [OSTI]

transcatheter implantation of heart valve prosthesis for thein apex of post-mortem heart (lower view). B C A Figure 5A.descending aorta in lambs. Eur Heart J. 2002;23:1045-49. 5.

White, Jennifer; Sun, Amy; Killien, Lauren; Evangelista, Dennis

2006-01-01T23:59:59.000Z

269

Classification of heart valve sounds from experiments in an anechoic water tank  

SciTech Connect (OSTI)

In vivo studies in both sheep and humans were plagued by a number of problems including movement artifacts, biological noise, low signal-to-noise ratio (SNR), chest-wall reverberation, and limited bandwidth recordings as discussed by [1]. To overcome these problems it was decided to record heart valve sounds under controlled conditions deep in an anechoic water tank, free from reverberation noise. The main goal of this experiment was to obtain measurements of ''pure'' heart valve sounds free of the scattering effects of the body. Experiments were conducted at the Transdec facility in San Diego [2]. We used a high quality hydrophone together with a wide-band data acquisition system [2]. We recorded sounds from 100 repetitions of the opening-closing cycles on each of 50 different heart valves, including 21 SLS valves and 29 intact valves. The power spectrum of the opening and closing phases of each cycle were calculated and outlier spectra removed as described by Candy [2]. In this report, we discuss the results of our classification of the heart valve sound measurements. The goal of this classification task was to apply the fundamental classification algorithms developed for the clinical data in 1994 and 1996 to the measurements from the anechoic water tank. From the beginning of this project, LLNL's responsibility has been to process and classify the heart valve sounds. For this experiment, however, we processed both the opening sounds and closing sounds for comparison purposes. The results of this experiment show that the classifier did not perform well because of low signal-to-noise ratio and excessive variability in signal power from beat-to-beat for a given valve.

Axelrod, M C; Clark, G A; Scott, D

1999-06-01T23:59:59.000Z

270

Proximity effects in superconducting triplet spin-valve F2/F1/S  

Science Journals Connector (OSTI)

Abstract We investigate the critical temperature Tc of F2/F1/S trilayers (Fi is a ferromagnetic metal and S is a singlet superconductor), where the long-range triplet superconducting component is generated at noncollinear magnetizations of the F layers. In this paper we demonstrate a possibility of the spin-valve effect mode selection (standard switching effect, the triplet spin-valve effect or reentrant T c ( ? ) dependence) by the variation of the F2/F1 interface transparency.

R.G. Deminov; L.R. Tagirov; R.R. Gaifullin; T.Yu. Karminskaya; M.Yu. Kupriyanov; Ya.V. Fominov; A.A. Golubov

2015-01-01T23:59:59.000Z

271

Externally heated valve engine -- An alternative to the Stirling engine  

SciTech Connect (OSTI)

A new concept of the Externally Heated Valve (EHV) engine is presented. The principle of the engine operation is described in the introduction to the paper. Heat delivered to the working medium (air) in the heater, or several heaters working commutatively, can come from a combustion chamber or other heat generator such as nuclear reactors or solar collectors. The engine construction is original entirely different from the well-known Stirling engine. New results of the EHV engine computer modeling are presented. This is connected with a new kind of the annular heater applied to the EHV engine. A whirl motion inside the heater is caused to ensure the proper condition of the heat exchanger during the whole engine cycle. Three heaters working commutatively have been considered in this model. Comparisons between the power and efficiency of the Stirling engine and EHV engine have been performed for the same engine capacity, rotational frequency, maximum and minimum temperatures of the working gas and for the same mean pressures of both the engine cycles. The power of the EHV engine is in this case over three times higher than the Stirling engine power, while the efficiency of both the engines is almost the same.

Kazimierski, Z. [Tohoku Gakuin Univ., Sendai, Miyagi (Japan). Research Div. in Mechanical Engineering; Brzeski, L. [Technical Univ. of Lodz (Poland). Dept. of Mechanical Engineering

1996-12-31T23:59:59.000Z

272

Risk assessment of drain valve failure in the K-West basin south loadout pit  

SciTech Connect (OSTI)

The drain valve located in the bottom of the K-West Basin South Loadout Pit (SLOP) could provide an additional leak path from the K Basins if the drain valve were damaged during construction, installation, or operation of the cask loading system. For the K-West Basin SLOP the immersion pail support structure (IPSS) has already been installed, but the immersion pail has not been installed in the IPSS. The objective of this analysis is to evaluate the risk of damaging the drain valve during the remaining installation activities or operation of the cask loading system. Valve damage, as used in this analysis, does not necessarily imply large amounts of the water will be released quickly from the basin, rather valve damage implies that the valve's integrity has been compromised. The analysis process is a risk-based uncertainty analysis where best engineering judgement is used to represent each variable in the analysis. The uncertainty associated with each variable is represented by a probability distribution. The uncertainty is propagated through the analysis by Monte Carlo convolution techniques. The corresponding results are developed as a probability distribution and the risk is expressed in terms of the corresponding complementary cumulative distribution function (''risk curve''). The total risk is the area under the ''risk curve''. The risk of potentially dropping a cask into or on the IPSS and damaging the drain valve is approximately 1 x 10{sup -4} to 2 x 10{sup -5} per year. The risk of objects falling behind the IPSS and damaging the valve is 3 x 10{sup -2} to 6 x 10{sup -3} per year. Both risks are expressed as drain value failure frequencies. The risk of objects falling behind the IPSS and damaging the valve can be significantly reduced by an impact limiter and/or installing a gating or plate over the area bounded by the back of the IPSS and the wall of the SLOP. With either of these actions there is a 90 percent confidence that the frequency of drain valve failure would be less than 1 x 10{sup -6} per year.

MORGAN, R.G.

1999-06-23T23:59:59.000Z

273

Optimal Design of a High-Speed On/Off Valve for a Hydraulic Hybrid Vehicle Application  

E-Print Network [OSTI]

Coefficient 0.6 same none eq Fluid Bulk Modulus 3.7 x 108 1.2 x 109 Pa Pc Check Valve Cracking Pressure 3.2 NOptimal Design of a High-Speed On/Off Valve for a Hydraulic Hybrid Vehicle Application Michael of Minnesota, Minneapolis, MN, USA ABSTRACT Control of hydraulic systems using high-speed on/off valves has

Li, Perry Y.

274

Processing of prosthetic heart valve sounds for single leg separation classification  

SciTech Connect (OSTI)

Efforts are concentrated on the sounds corresponding to the heart valve opening cycle. Valve opening and closing acoustics present additional information about the outlet strut condition---the structural component implicated in valve failure. The importance of the opening sound for single leg separation detection/classification is based on the fact that as the valve opens, the disk passively hits the outlet strut. The opening sounds thus yield direct information about outlet strut condition with minimal amount of disturbance caused by the energy radiated from the disk. Hence the opening sound is a very desirable acoustic signal to extract. Unfortunately, the opening sounds have much lower signal levels relative to the closing sounds and therefore noise plays a more significant role than during the closing event. Because of this it is necessary to screen the sounds for outliers in order to insure a high sensitivity of classification. Because of the sharp resonances appearing in the corresponding spectrum, a parametric processing approach is developed based on an autoregressive model which was selected to characterize the sounds emitted by the Bjork--Shiley convexo--concave (BSCC) valve during opening cycle. First the basic signals and the extraction process used to create an ensemble of heart valve sounds are briefly discussed. Next, a {ital beat} {ital monitor} capable of rejecting beats that fail to meet an acceptance criteria based on their spectral content is developed. Various approaches that have been utilized to enhance the screened data and produce a reliable {ital heart} {ital valve} {ital spectrogram} which displays the individual sounds (power) as a function of beat number and temporal frequency are discussed. Once estimated, the spectrogram and associated parameters are used to develop features supplied to the various classification schemes. Finally, future work aimed at even further signal enhancement and improved classifier performance is discussed.

Candy, J.V.; Jones, H.E. [University of California, Lawrence Livermore National Laboratory, P.O. Box 808, L-495, Livermore, California 94550 (United States)

1995-06-01T23:59:59.000Z

275

Classification of heart valve sounds from experiments in an anechoic water tank  

SciTech Connect (OSTI)

In vivo studies in both sheep and humans were plagued by a number of problems including movement artifacts, biological noise, low signal-to-noise ratio (SNR), chest-wall reverberation, and limited bandwidth recordings as discussed by [1]. To overcome these problems it was decided to record heart valve sounds under controlled conditions deep in an anechoic water tank, free from reverberation noise, including surface reflections. Experiments were conducted in a deep water tank at the Transdec facility in San Diego, which satisfies these requirements. The Transdec measurements are free of reverberations, but not totally free of acoustic and electrical noise. We used a high quality hydrophone together with a wide-band data acquisition system [2]. We recorded sounds from 100 repetitions of the opening-closing cycles on each of 50 different heart valves, including 21 SLS valves and 29 intact valves. The power spectrum of the opening and closing phases of each cycle were calculated and outlier spectra removed as described by Candy [2]. In this report, we discuss the results of our classification of the heart valve sound measurements. The goal of this classification task was to apply the fundamental classification algorithms developed for the clinical data in 1994 and 1996 to the measurements from the anechoic water tank. From the beginning of this project, LLNL's responsibility has been to process and classify the heart valve opening sounds. For this experiment, however, we processed both the opening sounds and closing sounds for comparison purposes. The results of this experiment show that the classifier did not perform well. We believe this is because of low signal-to-noise ratio and excessive variability in signal power from beat-to-beat for a given valve.

Axelrod, M C; Clark, G A; Scott, D

1999-06-01T23:59:59.000Z

276

Multi objective optimisation of an electromagnetic valve actuator Nicolas BELLEGARDE, Jean-Claude VANNIER, Philippe DESSANTE, Pierre VIDAL  

E-Print Network [OSTI]

Multi objective optimisation of an electromagnetic valve actuator Nicolas BELLEGARDE, Jean, weight, volume. 1. Notations a Thickness of the mobile part (mm) Slot's coefficient of occupation b

Paris-Sud XI, Université de

277

Rates & Repayment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Environmental Review-NEPA Financial Data Operations Planning & Projects Power Marketing Rates Rate Adjustments Transmission Ancillary Services Rates WAPA-137 Rate Order Environmental Review-NEPA Financial Data Operations Planning & Projects Power Marketing Rates Rate Adjustments Transmission Ancillary Services Rates WAPA-137 Rate Order Rates and Repayment Services Rates Current and Historical Rate Information Collbran Power Rates CRSP Power Rates CRSP Transmission System Rates CRSP Management Center interest rates Falcon-Amistad Power Rates Provo River Power Rates Rio Grande Power Rates Seedskadee Power Rates SLCA/IP Power Rates Rate Schedules & Supplemental Rate Information Current Rates for Firm Power, Firm & Non-firm Transmission Service, & Ancillary Services Current Transmission & Ancillary Services Rates Tariffs Components of the SLCA/IP Existing Firm Power Rate Cost Recovery Charge (CRC) Page MOA Concerning the Upper Colorado River Basin

278

ISOLOK VALVE ACCEPTANCE TESTING FOR DWPF SME SAMPLING PROCESS  

SciTech Connect (OSTI)

Evaluation of the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) cycle time identified several opportunities to improve the CPC processing time. Of the opportunities, a focus area related to optimizing the equipment and efficiency of the sample turnaround time for DWPF Analytical Laboratory was identified. The Mechanical Systems & Custom Equipment Development (MS&CED) Section of the Savannah River National Laboratory (SRNL) evaluated the possibility of using an Isolok{reg_sign} sampling valve as an alternative to the Hydragard{reg_sign} valve for taking process samples. Previous viability testing was conducted with favorable results using the Isolok sampler and reported in SRNL-STI-2010-00749 (1). This task has the potential to improve operability, reduce maintenance time and decrease CPC cycle time. This report summarizes the results from acceptance testing which was requested in Task Technical Request (TTR) HLW-DWPF-TTR-2010-0036 (2) and which was conducted as outlined in Task Technical and Quality Assurance Plan (TTQAP) SRNL-RP-2011-00145 (3). The Isolok to be tested is the same model which was tested, qualified, and installed in the Sludge Receipt Adjustment Tank (SRAT) sample system. RW-0333P QA requirements apply to this task. This task was to qualify the Isolok sampler for use in the DWPF Slurry Mix Evaporator (SME) sampling process. The Hydragard, which is the current baseline sampling method, was used for comparison to the Isolok sampling data. The Isolok sampler is an air powered grab sampler used to 'pull' a sample volume from a process line. The operation of the sampler is shown in Figure 1. The image on the left shows the Isolok's spool extended into the process line and the image on the right shows the sampler retracted and then dispensing the liquid into the sampling container. To determine tank homogeneity, a Coliwasa sampler was used to grab samples at a high and low location within the mixing tank. Data from the two locations were compared to determine if the contents of the tank were well mixed. The Coliwasa sampler is a tube with a stopper at the bottom and is designed to obtain grab samples from specific locations within the drum contents. A position paper (4) was issued to address the prototypic flow loop issues and simulant selections. A statistically designed plan (5) was issued to address the total number of samples each sampler needed to pull, to provide the random order in which samples were pulled and to group samples for elemental analysis. The TTR required that the Isolok sampler perform as well as the Hydragard sampler during these tests to ensure the acceptability of the Isolok sampler for use in the DWPF sampling cells. Procedure No.L9.4-5015 was used to document the sample parameters and process steps. Completed procedures are located in R&D Engineering job folder 23269.

Edwards, T.; Hera, K.; Coleman, C.; Jones, M.; Wiedenman, B.

2011-12-05T23:59:59.000Z

279

Apparatus and method for non-invasive diagnosis and control of motor operated valve condition  

DOE Patents [OSTI]

An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signal and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit. 28 figs.

Lyon, R.H.; Chai, J.; Lang, J.H.; Hagman, W.H.; Umans, S.D.; Saarela, O.J.

1997-01-14T23:59:59.000Z

280

Apparatus and method for non-invasive diagnosis and control of motor operated valve condition  

DOE Patents [OSTI]

An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signal and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit.

Lyon, Richard H. (Belmont, MA); Chai, Jangbom (Seoul, KR); Lang, Jeffrey H. (Sudbury, MA); Hagman, Wayne H. (Belmont, MA); Umans, Stephen D. (Belmont, MA); Saarela, Olli J. (Helsinki, FI)

1997-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Heart valve cardiomyocytes of mouse embryos express the serotonin transporter SERT  

SciTech Connect (OSTI)

Multiple evidence demonstrate a role for serotonin and its transporter SERT in heart valve development and disease. By utilizing a Cre/loxP system driven by SERT gene expression, we recently demonstrated a regionally restricted distribution of SERT-expressing cells in developing mouse heart. In order to characterize the cell types exhibiting SERT expression within the mouse heart valves at early developmental stages, in this study we performed immunohistochemistry for Islet1 (Isl1) and connexin-43 (Cx-43) on heart sections from SERT{sup Cre/+};ROSA26R embryos previously stained with X-gal. We observed the co-localization of LacZ staining with Isl1 labelling in the outflow tract, the right ventricle and the conal region of E11.5 mouse heart. Cx-43 labelled cells co-localized with LacZ stained cells in the forming atrioventricular valves. These results demonstrate the cardiomyocyte phenotype of SERT-expressing cells in heart valves of the developing mouse heart, thus suggesting an active role of SERT in early heart valve development.

Pavone, Luigi Michele [Department of Biological Structures, Functions and Technologies, University of Naples Federico II, Via F. Delpino 1, 80137 Naples (Italy); Department of Biochemistry and Medical Biotechnologies, University of Naples Federico II, Naples (Italy)], E-mail: pavone@dbbm.unina.it; Spina, Anna; Lo Muto, Roberta; Santoro, Dionea [Department of Biological Structures, Functions and Technologies, University of Naples Federico II, Via F. Delpino 1, 80137 Naples (Italy); Department of Biochemistry and Medical Biotechnologies, University of Naples Federico II, Naples (Italy); Mastellone, Vincenzo [Department of Experimental Medicine 'G. Salvatore', University of Magna Graecia, Catanzaro (Italy); Avallone, Luigi [Department of Biological Structures, Functions and Technologies, University of Naples Federico II, Via F. Delpino 1, 80137 Naples (Italy)

2008-12-12T23:59:59.000Z

282

Renovation and remaining life management techniques for the reliable operation of steam turbine valve casings  

SciTech Connect (OSTI)

Much attention has been focused on the renovation and remaining life management of steam turbine casings. Properly engineered casing repairs, design upgrades, and strategies such as thermal stress monitoring/control, have been successfully employed to keep older steam turbine casings operating reliably until projected plant decommissioning dates. These proven solutions have resulted in a much lower cost alternative to turbine casing replacement. Valve casings are also subject to the rigors of high pressure/temperature operating environments and have a significant replacement cost as well. The same techniques employed to renovate turbine casings can also be successfully applied to valve casings to ensure their reliable operation for the projected plant life. Of particular interest are design upgrades which can be introduced during the renovation. Advances in computer modeling and techniques such as Finite Element analysis have provided engineers with tools not available during the original casing design. This provides an opportunity to not only restore the casings to their original design, but to re-engineer the casings to exceed original design parameters. This paper will cover the engineering analysis of valve casing defects, restoration techniques, and design upgrades. Thermal stress monitoring will be introduced as a technique to manage remaining life. Typical failure modes in various valve casing designs as well as design improvements will be stressed. It will also use case studies to demonstrate the economic and technical advantages of valve and turbine casing renovation.

Rasmussen, D.M.; Otterlee, T.J. [Turbine Consultants, Inc., Milwaukee, WI (United States)

1994-12-31T23:59:59.000Z

283

Fast valve and nozzle for gas-puff operation of dense plasma focus  

Science Journals Connector (OSTI)

A simple and reliable valve and nozzle system for a very fast injection of gas has been designed and constructed for its use in gas-puff mode of dense plasma focus experiments. It delivers a very quick rise time: 55 ? s . The pressure measured in our setup at a distance of 15 mm from the nozzle output is about 0.285 mbar with a plenum pressure of 3 bars (absolute). The time between the valve aperture and pressure front arrival is 360 ? s . This result comes up as an average of about a hundred measurements. The energy input is 95 J (270 V on a 3000 ? F capacitor bank). The typical dimensions of the valve are 52 mm in diameter and 80 mm in length. The entire volume of the valve is then very small. The relative low pressure and voltage operation are significant advantages of this development. The performance of the valve satisfactorily fulfills the objectives of gas-puff plasma focus operation.

María M. Milanese; Jorge O. Pouzo; Osvaldo D. Cortázar; Roberto L. Moroso

2006-01-01T23:59:59.000Z

284

Nano-oxide-layer insertion and specular effects in spin valves: Experiment and theory  

Science Journals Connector (OSTI)

We report a systematic study of NOL (nano-oxide-layer) insertion and specular effects on the giant magnetoresistance (GMR) of single, synthetic, and dual spin valves, using a semiclassical Boltzmann theory. It is confirmed that the GMR ratio is enhanced by NOL insertion inside the pinned layer or after the free layer. The enhancements are primarily due to the contribution of the majority carriers. The NOL insertions inside the inactive layers of spin valves such as the seed, under, and capping layers reduce the GMR ratio. Though introducing a NOL before or after the Cu spacer would, in principle, significantly suppress the GMR ratio due to the blocking effect or the average effect of different spin channels, large positive or negative (inverse) GMR is found by assuming spin-dependent NOL specular reflections. We have also demonstrated that specular reflection, even beyond a capping layer, may result in reduction of GMR. Upon appropriate NOL insertion, the amplitude of curve of GMR versus thickness of individual layer of spin valves may be generally enhanced, but the shape may change, depending on whether the distance of the NOL to the layer is small or large (distance effect). Finally, it is found that most results obtained for the single realistic spin valves are applicable to synthetic and dual spin valves.

L. Wang; J. J. Qiu; W. J. McMahon; K. B. Li; Y. H. Wu

2004-06-03T23:59:59.000Z

285

Airpath Control of a SI Engine with Variable Valve Timing Actuators Thomas Leroy, Jonathan Chauvin and Nicolas Petit  

E-Print Network [OSTI]

Airpath Control of a SI Engine with Variable Valve Timing Actuators Thomas Leroy, Jonathan Chauvin with Variable Valve Timing (VVT) actuators. VVT devices are used to produce internal exhaust gas recirculation actuators affect the fresh air charge in the cylinders. This has an impact on the torque output (leading

286

Spin-dependent thermal and electrical transport in a spin-valve system Zheng-Chuan Wang,1  

E-Print Network [OSTI]

Spin-dependent thermal and electrical transport in a spin-valve system Zheng-Chuan Wang,1 Gang Su,1 governed by thermal processes at high temperature. The so-called spin-valve phenomenon is clearly uncovered, the quantum size effect on the thermal conduc- tance and the Peltier coefficient,2 the diffusive thermopower

Gao, Song

287

Fail save shut off valve for filtering systems employing candle filters  

DOE Patents [OSTI]

The invention relates to an apparatus that acts as a fail save shut off valve. More specifically, the invention relates to a fail save shut off valve that allows fluid flow during normal operational conditions, but prevents the flow of fluids in the event of system failure upstream that causes over-pressurization. The present invention is particularly well suited for use in conjunction with hot gas filtering systems, which utilize ceramic candle filters. Used in such a hot gas system the present invention stops the flow of hot gas and prevents any particulate laden gas from entering the clean side of the system.

VanOsdol, John (Fairmont, WV)

2006-01-03T23:59:59.000Z

288

Fail Save Shut Off Valve for Filtering Systems Employing Candle Filters  

DOE Patents [OSTI]

The invention relates to an apparatus that acts as a fail save shut off valve. More specifically, the invention relates to a fail save shut off valve that allows fluid flow during normal operational conditions, but prevents the flow of fluids in the event of system failure upstream that causes over-pressurization. The present invention is particularly well suited for use in conjunction with hot gas filtering systems, which utilize ceramic candle filters. Used in such a hot gas system the present invention stops the flow of hot gas and prevents any particulate laden gas from entering the clean side of the system.

VanOsdol, John

2006-01-03T23:59:59.000Z

289

LLNL heart valve condition classification project anechoic testing results at the TRANSDEC evaluation facility  

SciTech Connect (OSTI)

This report first briefly outlines the procedures and support/activation fixture developed at LLNL to perform the heart valve tests in an anechoic-like tank at the US Navy Transducer Evaluation Facility (TransDec) located in San Diego, CA. Next they discuss the basic experiments performed and the corresponding experimental plan employed to gather meaningful data systematically. The signal processing required to extract the desired information is briefly developed along with some of the data. Finally, they show the results of the individual runs for each valve, point out any of the meaningful features and summaries.

Candy, J V

1999-10-31T23:59:59.000Z

290

Spin-transfer switching of orthogonal spin-valve devices at cryogenic temperatures  

SciTech Connect (OSTI)

We present the quasi-static and dynamic switching characteristics of orthogonal spin-transfer devices incorporating an out-of-plane magnetized polarizing layer and an in-plane magnetized spin valve device at cryogenic temperatures. Switching at 12?K between parallel and anti-parallel spin-valve states is investigated for slowly varied current as well as for current pulses with durations as short as 200 ps. We demonstrate 100% switching probability with current pulses 0.6?ns in duration. We also present a switching probability diagram that summarizes device switching operation under a variety of pulse durations, amplitudes, and polarities.

Ye, L., E-mail: ly17@nyu.edu; Gopman, D. B.; Rehm, L.; Backes, D.; Wolf, G.; Kent, A. D. [Department of Physics, New York University, New York, New York 10003 (United States); Ohki, T. [Raytheon BBN Technologies, Cambridge, Massachusetts 02138 (United States); Kirichenko, A. F.; Vernik, I. V.; Mukhanov, O. A. [HYPRES, 175 Clearbrook Road, Elmsford, New York 10523 (United States)

2014-05-07T23:59:59.000Z

291

Assessment of Concrete Repair Techniques for Radiologically Contaminated Tank Farm Pump and Valve Pits  

SciTech Connect (OSTI)

As part of the scope of Project W-314, ''Tank Farm Restoration and Safe Operations,'' the condition of pump and valve pit walls and floors is being assessed, and repairs made as needed, to support upgrading the infrastructure necessary to safely transfer tank waste for treatment. Flaws in the surfaces of the pits (e.g., concrete crack/faults, protective coating deterioration) must be repaired to ensure containment integrity and to facilitate future decontamination of the pits. This engineering study presents a cost/risk/benefit evaluation of concrete and protective coating repair methods in pump and valve pits using various manual and remote tool systems.

MINTEER, D.J.

2000-09-19T23:59:59.000Z

292

Sealing off a carbon nanotube with a self-assembled aqueous valve for the storage of hydrogen in GPa pressure  

E-Print Network [OSTI]

The end section of a carbon nanotube, cut by acid treatment, contains hydrophillic oxygen groups. Water molecules can self-assemble around these groups to seal off a carbon nanotube and form an "aqueous valve". Molecular dynamics simulations on single-wall (12,12) and (15,15) tubes with dangling carboxyl groups show that the formation of aqueous valves can be achieved both in the absence of and in the presence of high pressure hydrogen. Furthermore, significant diffusion barriers through aqueous valves are identified. It indicates that such valves could hold hydrogen inside the tube with GPa pressure. Releasing hydrogen is easily achieved by melting the "aqueous valve". Such a design provides a recyclable and non- destructive way to store hydrogen in GPa pressure. Under the storage conditions dictated by sealing off the container in liquid water, the hydrogen density inside the container is higher than that for solid hydrogen, which promises excellent weight storage efficiency.

Chen, H Y; Gong, X G; Liu, Zhi-Feng

2012-01-01T23:59:59.000Z

293

Construction integrity assessment report (ETN-98-0005) S-Farm overground transfer (OGT) system valve pit 241-S-B to valve pit 241-S-D  

SciTech Connect (OSTI)

The S-Farm overground transfer (OGT) line will bypass the existing line(s), between valve pits 241-S-B and 241-S-D that no longer meet system requirements. The new OGT line will provide a waste transfer pipeline between these valve pits in support of saltwell pumping activities. The length of the OGT line is approximately 180 ft from pit to pit. The primary pipe is nominal 1-in. diameter stainless steel (SST) braided Ethylene-propylene Diene Monomer (EPDM) hose. The encasement pipe is a nominal 3-in., flanged, SST pipe made up of several different length pipe spool pieces (drawing H-2-829564, sh. 1 and sh. 2). The OGT line slopes from valve pit 241-S-B toward valve pit 241-S-D. At each end, the primary and encasement pipe connect to a pit entry spool piece. The pit entry spool pieces are constructed of prefabricated SST materials. These spool pieces allow for the separation of the primary and encasement pipelines after the pipes have entered the valve pits (drawing H-2-818280, sh. 2). The pit entry spool pieces also allow for leak detection of the encasement pipe at each end (drawing H-2-829564, sh. 2). The OGT encasement pipeline is supported above ground by adjustable height unistrut brackets and precast concrete bases (drawing H-2-829654, sh. 1). The pipeline is heat-traced and insulated. The heat tracing and insulation supply and retain latent heat that prevents waste solidification during transfers and provides freeze protection. The total length of the pipeline is above ground, thereby negating the need for cathodic corrosion protection. This Construction Integrity Assessment Report (CIAR) is prepared by Fluor Daniel Northwest for Numatec Hanford Corporation/Lockheed Martin Hanford Corporation, the operations contractor, and the U. S. Department of Energy, the system owner. The CIAR is intended to verify that construction was performed in accordance with the provisions of Washington Administrative Code, WAC-173-303-640 (3) (c), (e), (f) and (h).

HICKS, D.F.

1999-08-12T23:59:59.000Z

294

An Active Motion Compensation Instrument for Beating Heart Mitral Valve Surgery  

E-Print Network [OSTI]

An Active Motion Compensation Instrument for Beating Heart Mitral Valve Surgery Daniel T. Kettler) is described. The resulting instrument was tested in user trials under a series of positional error bandwidth, creating a wrist that can operate in the restricted workspace within the heart, and ensuring

295

MOTION PLANNING CONTROL OF THE AIRPATH OF AN S.I. ENGINE WITH VALVE  

E-Print Network [OSTI]

to controlling the air mass aspirated in the cylinder. Besides, it is also desired to reduce engine pollutantMOTION PLANNING CONTROL OF THE AIRPATH OF AN S.I. ENGINE WITH VALVE TIMING ACTUATORS T. Leroy , J, France Abstract: We address the control of the airpath of a turbocharged S.I. engine equipped

Boyer, Edmond

296

Inhibition of aortic wall calcification in bioprosthetic heart valves by ethanol pretreatment: Biochemical and  

E-Print Network [OSTI]

Inhibition of aortic wall calcification in bioprosthetic heart valves by ethanol pretreatment 16 September 1997; 20 February 1998 Abstract: The effectiveness of ethanol pretreatment on pre was previously demonstrated, and the mechanism of action of ethanol was attributed in part to both lipid removal

Zand, Robert

297

Condition monitoring of motor-operated valves in nuclear power plants Pierre Granjon  

E-Print Network [OSTI]

Condition monitoring of motor-operated valves in nuclear power plants Pierre Granjon Gipsa of nuclear power plants. Unfortunately, today's policies present a major drawback. Indeed, these monitoring is illustrated through experimental data. 1. Introduction Nuclear power provides about 14% of the world

Boyer, Edmond

298

Motion planning for experimental air path control of a variable-valve-timing spark ignition engine  

E-Print Network [OSTI]

to driveability problems) and on the fuel/air ratio (FAR) (leading to pollution peaks). To compensateMotion planning for experimental air path control of a variable-valve-timing spark ignition engine Syste´mes, Mines-ParisTech 60, bd St Michel, 75272 Paris, France a r t i c l e i n f o Article history

299

The Use of Coanda Wall Attachment Fluidic Switches as Gas Chromatographic Valves  

Science Journals Connector (OSTI)

......chromatographs operating in a process control application are quite...many research- ers since the commercialization of the chromatograph in the...is particularly evident in process chromatographs. Valves which...conditions are prone to fail in a process control environment where......

Raymond Annino; Jim Leone

1982-01-01T23:59:59.000Z

300

Low energy ion beam assisted deposition of a spin valve J. J. Quan,a  

E-Print Network [OSTI]

Low energy ion beam assisted deposition of a spin valve J. J. Quan,a S. A. Wolf, and H. N. G. Wadley Department of Materials Science and Engineering, School of Engineering and Applied Science interfacial structures can be created using low energy, ion assisted vapor deposition techniques with ion

Wadley, Haydn

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Towards Real-Time and Memory Efficient Predictions of Valve States in Diesel Engines  

E-Print Network [OSTI]

Towards Real-Time and Memory Efficient Predictions of Valve States in Diesel Engines Philippe Komma phase complexity while retaining good generalization performance. I. INTRODUCTION In automotive engines T¨ubingen, Germany {philippe.komma, andreas.zell}@uni-tuebingen.de system for a diesel engine

Zell, Andreas

302

A characterization of check valve degradation and failure experience in the nuclear power industry: 1984-1990. Volume 1  

SciTech Connect (OSTI)

Check valve operating problems in recent years have resulted in significant operating transients, increased cost and decreased system availability. As a result, additional attention has beau given to check valves by utilities (resulting in the formation of the Nuclear Industry Check Valve Group), as well as the US Nuclear Regulatory Commission and the American Society of Mechanical Engineers Operation and Maintenance Committee. All these organizations have the fundamental goal of ensuring reliable operation of check valves. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. A detailed review of historical failure data, available through the Institute of Nuclear Power Operation`s Nuclear Plant Reliability Data System, has been conducted. The focus of the review is on check valve failures that have involved significant degradation of the valve internal parts. A variety of parameters are considered, including size, age, system of service, method of failure discovery, the affected valve parts, attributed causes, and corrective actions.

Casada, D.A.; Todd, M.D. [Oak Ridge National Lab., TN (United States)] [Oak Ridge National Lab., TN (United States)

1993-09-01T23:59:59.000Z

303

Application of Modelica/MWorks on modeling, simulation and optimization for electro-hydraulic servo valve system  

Science Journals Connector (OSTI)

Electro-hydraulic servo valve is a typical complicated multi-domain system constituted by mechanical electric hydraulic and magnetic components which is widely used in electro-hydraulic servo systems such as construction machinery heavy equipment weapon and so forth. The traditional method of modeling and simulation of servo valve is based on block diagram or signal flow which cannot describe the servo valve system from components level nor be used in modeling and simulation of overall servo systems. In the procedure of traditional method computational causality must be involved in modeling of servo valve which is inconvenient to execute modification on components or parameters. Modelica is an object-oriented modeling language which is suited for large complex heterogeneous and multi-domain systems. The key features of Modelica are multi-domain object-oriented and non-causal which are suitable for modeling of servo valve and make the model readable reusable and easy to modify. The simulation results show similar curves with traditional method. This new servo valve modeling and simulation method can provide the engineers a more efficient way to design and optimize a servo valve and an overall servo system.

Ming Li; Guang Meng; Jianping Jing; Jinyang Liu; Zuoyang Zhong

2012-01-01T23:59:59.000Z

304

Analysis of system performance losses due to the reversing valve for a heat pump using R-410a  

SciTech Connect (OSTI)

A traditional reversing valve enables a heat pump to operate in the heating mode or cooling mode by switching the refrigerant flow path through the indoor and outdoor coils, thereby changing the functions of the two heat exchangers. However, the presence of a reversing valve causes additional pressure drops and undesired heat exchange. The objective of this research was to measure the overall effects of a reversing valve on a 3-ton heat pump system using R-401a and make comparisons to the same valve's performance with R-22 as the refrigerant. The experiments included tests of under- and over-sized valves at the same test conditions. Also, the effects of pressure drops and of heat transfer combined with mass leakage on system and compressor performance were analyzed. It was found that the use of a larger (oversized) reversing valve to reduce pressure drops provided only limited performance gains. Also, changing refrigerant from R-22 to R-410a resulted in an increase in mass leakage but did not significantly change the effect that the reversing valve had on the system COP.

Fang, W.; Nutter, D.W.

1999-07-01T23:59:59.000Z

305

Chlorite Dissolution Rates  

SciTech Connect (OSTI)

Spreadsheets provides measured chlorite rate data from 100 to 300C at elevated CO2. Spreadsheet includes derived rate equation.

Carroll, Susan

2013-07-01T23:59:59.000Z

306

Chlorite Dissolution Rates  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Spreadsheets provides measured chlorite rate data from 100 to 300C at elevated CO2. Spreadsheet includes derived rate equation.

Carroll, Susan

307

Power Rate Cases (pbl/rates)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Choices (2003-06) Power Function Review (PFR) Firstgov Power Rate Cases BPA's wholesale power rates are set to recover its costs and repay the U.S. Treasury for the Federal...

308

Detection of ``single-leg separated`` heart valves using statistical pattern recognition with the nearest neighbor classifier  

SciTech Connect (OSTI)

The goal of this work was to detect ``single-leg separated`` Bjoerk-Shiley Convexo-Concave heart valves which had been implanted in sheep. A ``single-leg separated`` heart valve contains a fracture in the outlet strut resulting in an increased risk of mechanical failure. The approach presented in this report detects such fractures by applying statistical pattern recognition with the nearest neighbor classifier to the acoustic signatures of the valve opening. This approach is discussed and results of applying it to real data are given.

Buhl, M.R.; Clark, G.A.; Candy, J.V.; Thomas, G.H.

1993-07-16T23:59:59.000Z

309

Detection of ``single-leg separated`` heart valves using statistical pattern recognition with the nearest neighbor classifier. Revision 1  

SciTech Connect (OSTI)

The goal of this work was to detect ``single-leg separated`` Bjoerk-Shiley Convexo-Concave heart valves which had been implanted in sheep. A ``single-leg separated`` heart valve contains a fracture in the outlet strut resulting in an increased risk of mechanical failure. The approach presented in this report detects such fractures by applying statistical pattern recognition with the nearest neighbor classifier to the acoustic signatures of the valve opening. This approach is discussed and results of applying it to real data are given.

Buhl, M.R.; Clark, G.A.; Candy, J.V.; Thomas, G.H.

1993-12-01T23:59:59.000Z

310

A custom-designed limited-angle actuator for an electromechanical engine valve drive Part II: Fabrication and evaluation  

E-Print Network [OSTI]

Research has shown that variable valve timing (VVT) can improve significantly the performance of internal combustion (IC) engines, including higher fuel efficiencies, lower emissions, and larger torque outputs at each point ...

Kassakian, John G.

311

A study on flow characteristics and discharge coefficients of safety valve used in LNG/LNG-FPSO ships  

Science Journals Connector (OSTI)

The safety valves used in liquefied natural gas — floating production storage and offloading (LNG-FPSO) ships play an important role in ... controlling the release of liquefied natural gas (LNG) from pipes in an

Jun-Ho Bae; Sung-Jin Kim; Moon-Saeng Kim…

2011-09-01T23:59:59.000Z

312

Fault Current Limit (FCL) Technology (Magnetic Valve Controlled Reactor-Type Fault Current Limiter Principle and Simulation)  

Science Journals Connector (OSTI)

Summarized the FCL practical research which faces to the key technical problems, briefly introduces the study of magnetic valve controllable reactor type fault current limiter principle, and the simulation result...

Chunzhe Shi

2012-01-01T23:59:59.000Z

313

A Four-Valve Pulse Tube Cryocooler with a Cooling Power over 30 W at 80 K  

Science Journals Connector (OSTI)

A single stage four-valve pulse tube cryocooler with a large cooling power at 80 K has been built and ... investigating the influence of pulse tube size on cooling performance. Initial test demonstrated that the ...

R. Li; K. Kanao; N. Watanabe; Y. Kanazawa

1998-01-01T23:59:59.000Z

314

Replace Pressure-Reducing Valves with Backpressure Turbogenerators: Office of Industrial Technologies (OIT) Steam Tip Fact Sheet No. 20  

SciTech Connect (OSTI)

Many industrial facilities produce steam at a higher pressure than is demanded by process requirements. Steam passes through pressure-reducing valves (PRVs, also known as letdown valves) at various locations in the steam distribution system to let down or reduce its pressure. A non-condensing or backpressure steam turbine can perform the same pressure-reducing function as a PRV, while converting steam energy into electrical energy.

Not Available

2002-01-01T23:59:59.000Z

315

Post-Remedial Action Report the Chapman Valve Site E I P I I  

Office of Legacy Management (LM)

for for Post-Remedial Action Report the Chapman Valve Site E I P I I I t I 1 I I I 1 I li I I Pnnted on recycledkecyclable paper 24 19 0186 1 DOE/OW21949-408 Formerly Utilized Sites Remed Contr: al Action Program (FUSRAP) L C t NO. DE-AC05-91 OR21 949 Indian Orchard, assac h.usetts November 1996 DOE/OR/2 1949-408 POST-REMEDIAL ACTION REPORT FOR THE CHAPMAN VALVE SITE INDIAN ORCHARD, MASSACHUSETTS NOVEMBER 1996 Prepared for United States Department of Energy Oak Ridge Operations Office Under Contract No. DE-AC05-91 OR2 1949 Bechtel National, Inc. Oak Ridge, Tennessee . . Bechtel Job No. 14501 CONTENTS Page . FIGURES ................................................................................... 1 .............................................................. iv

316

Bimodal switching field distributions in all-perpendicular spin-valve nanopillars  

SciTech Connect (OSTI)

Switching field measurements of the free layer element of 75?nm diameter spin-valve nanopillars reveal a bimodal distribution of switching fields at low temperatures (below 100?K). This result is inconsistent with a model of thermal activation over a single perpendicular anisotropy barrier. The correlation between antiparallel to parallel and parallel to antiparallel switching fields increases to nearly 50% at low temperatures. This reflects random fluctuation of the shift of the free layer hysteresis loop between two different magnitudes, which may originate from changes in the dipole field from the polarizing layer. The magnitude of the loop shift changes by 25% and is correlated to transitions of the spin-valve into an antiparallel configuration.

Gopman, D. B., E-mail: daniel.gopman@physics.nyu.edu; Kent, A. D. [Department of Physics, New York University, New York, New York 10003 (United States); Bedau, D.; Katine, J. A. [HGST San Jose Research Center, San Jose, California 95135 (United States); Mangin, S. [Institut Jean Lamour, UMR CNRS 7198 Université de Lorraine, Nancy (France); Fullerton, E. E. [CMRR, University of California at San Diego, La Jolla, California 92093 (United States)

2014-05-07T23:59:59.000Z

317

Testing of one-inch UF{sub 6} cylinder valves under simulated fire conditions  

SciTech Connect (OSTI)

Accurate computational models which predict the behavior of UF{sub 6} cylinders exposed to fires are required to validate existing firefighting and emergency response procedures. Since the cylinder valve is a factor in the containment provided by the UF{sub 6} cylinder, its behavior under fire conditions has been a necessary assumption in the development of such models. Consequently, test data is needed to substantiate these assumptions. Several studies cited in this document provide data related to the behavior of a 1-inch UF{sub 6} cylinder valve in fire situations. To acquire additional data, a series of tests were conducted at the Paducah Gaseous Diffusion Plant (PGDP) under a unique set of test conditions. This document describes this testing and the resulting data.

Elliott, P.G. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

1991-12-31T23:59:59.000Z

318

Solids throttling valves for coal conversion and utilization development. Final report  

SciTech Connect (OSTI)

A complete test system to test, evaluate, and develop control valves for slurry letdown service in coal liquefaction plants is needed. The site identified for the test system was the SRC II Pilot Plant located at Ft. Lewis, Washington. The US Department of Energy, Morgantown Energy Technology Center, requested a test system design that would enable testing of various configuration letdown valves that would be compatible with the existing facility and have minimum impact on Pilot Plant operations. Drawings and specifications for such a test system were prepared, coordinated with Ft. Lewis personnel, revised to reflect Ft. Lewis operating personnel comments, and approved for use by the Morgantown Energy Technology Center. These drawings and specifications will enable the test system to be built, installed, and integrated with the existing facility by a general contractor.

Sine, G.C.

1980-11-01T23:59:59.000Z

319

Project W-314 Specific Test and Evaluation Plan 241-AN-A Valve Pit  

SciTech Connect (OSTI)

The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made to the 241-AN-A Valve Pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system's performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP).

HAMMERS, J.S.

1999-08-25T23:59:59.000Z

320

Mechanisms of bioprosthetic heart valve failure: Fatigue causes collagen denaturation and glycosaminoglycan loss  

E-Print Network [OSTI]

caused progressive damage to the molecular structure of type I collagen as assessed by Fourier transform aortic valve cusps were 65.2 ± 8.66 g uronic acid/10 mg of dry weight for control and 7.91 ± 1.1 g uronic acid/10 mg of dry weight for 10­300 million cycled cusps. Together, these molecular changes contribute

Zand, Robert

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Composition pulling effect and strain relief mechanism in AlGaN/AlN distributed Bragg reflectors  

SciTech Connect (OSTI)

We report on the composition pulling effect and strain relief mechanism in AlGaN/AlN distributed Bragg reflectors (DBRs) grown on GaN template/{alpha}-Al{sub 2}O{sub 3}(0001) by metal organic chemical vapor deposition. The reciprocal space mapping contours reveal that these DBRs are coherently grown. Cross-section transmission electron microscopy image of the AlGaN/AlN DBRs and the energy-dispersive x-ray analysis indicate that an AlGaN layer with gradient Al composition is located between the Al{sub 0.4}Ga{sub 0.6}N and AlN layers along the [0001] direction. It is attributed to the fact that Ga atoms in AlGaN are pulled and segregated to the upper layer by the strain. The density of strain energy is estimated to reduce more than one order by forming this quasi-three-sublayer structure comparing to the designed bi-sublayer structure.

Liu, B.; Zhang, R.; Ji, X. L.; Fu, D. Y.; Xie, Z. L.; Chen, D. J.; Chen, P.; Jiang, R. L.; Zheng, Y. D. [Jiangsu Provincial Key Laboratory of Advanced Photonic and Electronic Materials, School of Electronic Science and Engineering, Nanjing National Laboratory of Microstructures, Nanjing University, Nanjing 210093 (China); Zheng, J. G. [California Institute for Telecommunications and Information Technology, University of California, Irvine, California 92697-2800 (United States)

2011-06-27T23:59:59.000Z

322

VARIABLE FIRING RATE OIL BURNER USING PULSE FUEL FLOW CONTROL.  

SciTech Connect (OSTI)

The residential oil burner market is currently dominated by the pressure-atomized retention head burner, which has an excellent reputation for reliability and efficiency. In this burner, oil is delivered to a fuel nozzle at pressures from 100 to 150 psi. In addition, to atomizing the fuel, the small, carefully controlled size of the nozzle exit orifice serves to control the burner firing rate. Burners of this type are currently available at firing rates of more than 0.5 gallons-per-hour (70,000 Btu/hr). Nozzles have been made for lower firing rates, but experience has shown that such nozzles suffer rapid fouling of the necessarily small passages, leading to bad spray patterns and poor combustion performance. Also, traditionally burners and the nozzles are oversized to exceed the maximum demand. Typically, this is figured as follows. The heating load of the house on the coldest day for the location is considered to define the maximum heat load. The contractor or installer adds to this to provide a safety margin and for future expansion of the house. If the unit is a boiler that provides domestic hot water through the use of a tankless heating coil, the burner capacity is further increased. On the contrary, for a majority of the time, the heating system is satisfying a much smaller load, as only rarely do all these demands add up. Consequently, the average output of the heating system has to be much less than the design capacity and this is accomplished by start and stop cycling operation of the system so that the time-averaged output equals the demand. However, this has been demonstrated to lead to overall efficiencies lower than the steady-state efficiency. Therefore, the two main reasons for the current practice of using oil burners much larger than necessary for space heating are the unavailability of reliable low firing rate oil burners and the desire to assure adequate input rate for short duration, high draw domestic hot water loads. One approach to solve this problem is to develop a burner, which can operate at two firing rates, with the lower rate being significantly lower than 0.5 gallons per hour. This paper describes the initial results of adopting this approach through a pulsed flow nozzle. It has been shown that the concept of flow modulation with a small solenoid valve is feasible. Especially in the second configuration tested, where the Lee valve was integrated with the nozzle, reasonable modulation in flow of the order of 1.7 could be achieved. For this first prototype, the combustion performance is still not quite satisfactory. Improvements in operation, for example by providing a sharp and positive shut-off so that there is no flow under low pressures with consequent poor atomization could lead to better combustion performance. This could be achieved by using nozzles that have shut off or check valves for example. It is recommended that more work in cooperation with the valve manufacturer could produce a technically viable system. Marketability is of course a far more complex problem to be addressed once a technically viable product is available.

KRISHNA,C.R.; BUTCHER,T.A.; KAMATH,B.R.

2004-10-01T23:59:59.000Z

323

Compact, electro-hydraulic, variable valve actuation system providing variable lift, timing and duration to enable high efficiency engine combustion control  

Broader source: Energy.gov [DOE]

Discusses development of advanced variable valve actuation system to enable high efficiency combustion highlighting advances to improving system packaging while reducing cost

324

rates | OpenEI  

Open Energy Info (EERE)

rates rates Dataset Summary Description This dataset, compiled by NREL and Ventyx, provides average residential, commercial and industrial electricity rates by zip code for both investor owned utilities (IOU) and non-investor owned utilities. Note: the file includes average rates for each utility, but not the detailed rate structure data found in the database available via the zip-code look-up feature on the OpenEI Utilities page (http://en.openei.org/wiki/Gateway:Utilities). The data was released by NREL/Ventyx in February 2011. Source NREL and Ventyx Date Released February 24th, 2012 (2 years ago) Date Updated Unknown Keywords electric rates rates US utilities Data text/csv icon IOU rates by zipcode (csv, 1.7 MiB) text/csv icon Non-IOU rates by zipcode (csv, 2.1 MiB)

325

Historical Interest Rates  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Current and Historical Interest Rates Current and Historical Interest Rates The table lists interest rates, from the project's inception through the present, for all projects with repayment supervised by the CRSP MC. The latest available interest rate is used for all future interest rate calculations. The Amistad-Falcon, Collbran, Provo River, and Rio Grande Projects are all assigned the average daily "Yield Rate" calculated by the U.S. Treasury, on an annual basis, for Treasury bonds having terms of 15 years or more remaining to maturity. The calculated yield rate is rounded to the nearest one-eighth of one percent. The yield rate is based upon the bond's interest rate, as well as its market value. The Colorado River Storage Project and its participating projects, Dolores and Seedskadee, are assigned the average daily "Coupon Rate," annualized for the same U.S. Treasury bonds used in "Yield Rate" calculations. The coupon rate is the interest rate that the bond carries upon its face.

326

Cost Analysis Rate Settin  

E-Print Network [OSTI]

Cost Analysis and Rate Settin for Animal Research Facilities #12;#12;Cost Analysis and Rate ... .. . ...................... . . . ................................. . .... 7 Chapter 2 Preparation for Cost Analysis ......................................................... 9 Chapter 3 Assignment of Costs to Animal Research Facility Cost Centers

Baker, Chris I.

327

Magnetism reflectometer study shows LiF layers improve efficiency in spin valve devices  

SciTech Connect (OSTI)

New, more efficient materials for spin valves - a device used in magnetic sensors, random access memories, and hard disk drives - may be on the way based on research using the magnetism reflectometer at Oak Ridge National Laboratory (ORNL). Spin valve devices work by means of two or more conducting magnetic material layers that alternate their electrical resistance depending on the layers alignment. Giant magnetoresistance is a quantum mechanical effect first observed in thin film structures about 20 years ago. The effect is observed as a significant change in electrical resistance, depending on whether the magnetization of adjacent ferromagnetic layers is in a parallel or an antiparallel magnetic alignment. 'What we are doing here is developing new materials. The search for new materials suitable for injecting and transferring carriers with a preferential spin orientation is most important for the development of spintronics,' said Valeria Lauter, lead instrument scientist on the magnetism reflectometer at the Spallation Neutron Source (SNS), who collaborated on the experiment. The researchers discovered that the conductivity of such materials is improved when an organic polymer semiconductor layer is placed between the magnetic materials. Organic semiconductors are now the material of choice for future spin valve devices because they preserve spin coherence over longer times and distances than conventional semiconductors. While research into spin valves has been ongoing, research into organic semiconductors is recent. Previous research has shown that a 'conductivity mismatch' exists in spin valve systems in which ferromagnetic metal electrodes interface with such organic semiconductors as Alq3 ({pi}-conjugated molecule tris(8-hydroxy-quinoline) aluminium). This mismatch limits the efficient injection of the electrons from the electrodes at the interface with the semiconductor material. However, lithium fluoride (LiF), commonly used in light-emitting diodes, has been found to enhance the injection of electrons through the semiconductor. Researchers from the University of Alabama and ORNL used polarized neutrons at the magnetism reflectometer at SNS to investigate the electronic, magnetic, and structural properties of the electrodes in a novel system. In this system, the magnetic layers cobalt and Ni{sub 80}Fe{sub 20} are interfaced with spacer layers composed of the organic semiconductor Alq3. A coupling layer of LiF is inserted to separate the magnetized layers from the semiconductor. 'ALQ3 is an organic semiconductor material,' said Lauter. 'Normally in these systems a first magnetic layer is grown on a hard substrate so that one can get the controlled magnetic parameters. Then you grow the organic semiconductor layer, followed by another magnetic material layer, such as cobalt.' In addition to determining the effect of the LiF layers on the efficiency of the electron injection, the researchers wanted to determine the magnetic properties of the cobalt and Ni{sub 80}Fe{sub 20} as well as the interfacial properties: whether there is interdiffusion of cobalt through the LiF layer to the semiconductor, for example. The researchers used polarized neutrons at beam line 4A to probe the entire, layer-by-layer assembly of the system. 'Reflectometry with polarized neutrons is a perfect method to study thin magnetic films,' Lauter said. 'These thin films - if you put one on a substrate, you see it just like a mirror. However, this mirror has a very complicated internal multilayer structure. The neutrons look inside this complicated structure and characterize each and every interface. Due to the depth sensitivity of the method, we measure the structural and magnetic properties of each layer with the resolution of 0.5 nm. The neutron scattering results found that inserting LiF as a barrier significantly improves the quality of the interface, increasing the injection of electrons from the magnetic layer through the organic semiconductor in the spin valve and enhancing the overall properties of the system. In related work the magneti

Bardoel, Agatha A [ORNL; Lauter, Valeria [ORNL; Szulczewski, Greg J [ORNL

2012-01-01T23:59:59.000Z

328

A characterization of check valve degradation and failure experience in the nuclear power industry: 1991 Failures, Volume 2  

SciTech Connect (OSTI)

Review and characterization of check valve failures taken from the Institute of Nuclear Power Operation`s Nuclear Plant Reliability Data System was performed in accordance with part two of a three-phase project sponsored by the US Nuclear Regulatory Commission. The analysis was performed for check valve failures occurring in 1991 and is intended to update the previous analysis performed for the time period 1984--1990. To maintain consistency and for ease of the 1991 analysis presents the same parameters and cross-correlations in essentially the same format as the 1984--1990 study. Additional data was obtained for the 1991 analysis, including information related to specific check valve type. This information is presented in a separate section of the report.

McElhaney, K.L. [Oak Ridge National Lab., TN (United States)

1995-07-01T23:59:59.000Z

329

488 Brazilian Journal of Physics, vol. 36, no. 2A, June, 2006 Spin Valve Effect and Hall Resistance in a Wide Parabolic Well  

E-Print Network [OSTI]

488 Brazilian Journal of Physics, vol. 36, no. 2A, June, 2006 Spin Valve Effect and Hall Resistance: Spin valve; Hall resistance; AlcGa1-cAs parabolic wells I. INTRODUCTION The Hall effect is very known by the formula Rxy = R0B+RSM, where B is ap- plied magnetic field, R0 is the ordinary Hall coefficient, and RS

Gusev, Guennady

330

Analysis of an extremely fast valve opening camless system to improve transient performance in a turbocharged high speed direct injection diesel engine  

Science Journals Connector (OSTI)

This article describes a theoretical study on the performance optimisation of a high speed direct injection turbocharged diesel engine equipped with an electro-hydraulic variable valve actuation 'camless' system. This system provides extremely fast valve opening and closing slopes. Thus, its potential for recovering part of the energy lost in the valves by reducing gas flow sonic conditions in the valve throat has been investigated. This study has been mainly focused on the analysis of engine performance during a load transient evolution, but the full load steady state attained at the end of the load transient has been also discussed. The results of this investigation have confirmed important improvements in engine performance during the load transient owing to less energy being lost across the valves, which directly results in more energy being available in the turbine. This benefit has also been observed at full load steady state conditions.

J. Benajes; J.R. Serrano; V. Dolz; R. Novella

2009-01-01T23:59:59.000Z

331

About the Ratings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2008 Ratings Changes 2008 Ratings Changes EPA's "New" Fuel Economy Ratings Video about EPA's New Fuel Economy Ratings Windows Media Video (6.8 MB) Quicktime Video (7.8 MB) Text Version EPA changed the way it estimates fuel economy starting with the 2008 model year. This "new" way of estimating fuel economy supplements the previous method by incorporating the effects of Faster speeds and acceleration Air conditioner use Colder outside temperatures What else do I need to know about the "new" ratings? The tests lower MPG estimates for most vehicles. View old/new MPG ratings for a specific vehicle The actual mileage you get will still vary based on your driving habits, traffic conditions, and other factors. All MPG estimates in Find-a-Car have been converted to the new

332

Helium ion beam milling to create a nano-structured domain wall magnetoresistance spin valve  

Science Journals Connector (OSTI)

We have fabricated and measured single domain wall magnetoresistance devices with sub-20 nm gap widths using a novel combination of electron beam lithography and helium ion beam milling. The measurement wires and external profile of the spin valve are fabricated by electron beam lithography and lift-off. The critical bridge structure is created using helium ion beam milling, enabling the formation of a thinner gap (and so a narrower domain wall) than that which is possible with electron beam techniques alone. Four-point probe resistance measurements and scanning electron microscopy are used to characterize the milled structures and optimize the He ion dose. Successful operation of the device as a spin valve is demonstrated, with a 0.2% resistance change as the external magnetic field is cycled. The helium ion beam milling efficiency as extracted from electrical resistance measurements is 0.044 atoms/ion, about half the theoretical value. The gap in the device is limited to a maximum of 20 nm with this technique due to sub-surface swelling caused by injected ions which can induce catastrophic failure in the device. The fine patterning capabilities of the helium ion microscope milling technique indicate that sub-5 nm constriction widths could be possible.

Yudong Wang; S A Boden; D M Bagnall; H N Rutt; C H de Groot

2012-01-01T23:59:59.000Z

333

Motor current signature analysis for determining operational readiness of motor-operated valves (MOVs)  

SciTech Connect (OSTI)

Motor current signature analysis (MCSA) is a novel diagnostic process for condition monitoring of electric-motor-driven mechanical equipment (e.g., pumps, motor-operated valves, compressors, and processing machinery). The MCSA process identifies, characterizes, and trends over time the instantaneous load variations of mechanical equipment in order to diagnose changes in the condition of the equipment (e.g., due to degradation or service wear), which, if allowed to continue, may lead to failure. It monitors the instantaneous variations (noise content) in the electric current flowing through the power leads to the electric motor that drives the equipment. The motor itself thereby acts as a transducer, sensing both large and small, long-term and rapid, mechanical load variations and converting them to variations in the induced current generated in the motor windings. This motor current noise signature is detected, amplified, and further processed as needed to examine its time domain and frequency domain (spectral) characteristics. The operational principles of MCSA and the nonintrusive data collection apparatus and procedure used with MOVs will be described. Data collected from MOVs in both laboratory and in-plant environments will also be shown to illustrate the ability of MCSA to ''see'' the detailed inner workings of the valve and operator and thus to detect degraded performance at an incipient stage. (Set of 18 vugraphs)

Kryter, R.C.; Haynes, H.D.

1987-01-01T23:59:59.000Z

334

Effective Rate Period  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Fiscal Year 2014 Fiscal Year 2014 Effective Rate Period As of Beginning of the FY 10/01/2013 - 09/30/2014 Mid-Year Changes (if applicable) 10/01/2013 - 09/30/2014 Power Rates Annual Revenue Requirement Rate Schedule Power Revenue Requirement $73,441,557 CV-F13 Base Resource Revenue Requirement $69,585,875 First Preference Revenue Requirement $3,855,682

335

LCC Guidance Rates  

Broader source: Energy.gov [DOE]

Notepad text file provides the LCC guidance rates in a numbered format for the various regions throughout the U.S.

336

Draft Tiered Rate Methodology  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

year's weather and other specific factors are removed from the loads of irrigated agriculture. ( ) "Irrigation Rate Mitigation" means the form of a discount by BPA to...

337

Heart Rate Artifact Suppression.  

E-Print Network [OSTI]

??Motion artifact strongly corrupts heart rate measurements in current pulse oximetry systems. In many, almost any motion will greatly diminish the system’s ability to extract… (more)

Dickson, Christopher

2012-01-01T23:59:59.000Z

338

Residential Solar Valuation Rates  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Residential Solar Valuation Rates Karl R. Rbago Rbago Energy LLC 1 The Ideal Residential Solar Tariff Fair to the utility and non-solar customers Fair compensation to...

339

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... ACS MEMBER RATES "Situations Wanted" advertisements will be classified by the chemical held designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2000-02-21T23:59:59.000Z

340

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... ACS MEMBER RATES "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

1997-03-24T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Energy-Saving Adaptive Robust Motion Control of Single-Rod Hydraulic Cylinders with Programmable Valves 1  

E-Print Network [OSTI]

- ety's need for energy conservation while without sacrificing the achievable motion control accuracy that the meter-in and meter-out orifices are mechanically linked together in a typical directional control valve of activities in industry on breaking the mechanical linkage between the meter-in and meter-out orifices

Yao, Bin

342

Energy-Saving Control of Single-Rod Hydraulic Cylinders with Programmable Valves and Improved Working Mode Selection  

E-Print Network [OSTI]

Energy-Saving Control of Single-Rod Hydraulic Cylinders with Programmable Valves and Improved. ABSTRACT This paper studies the energy-saving adaptive robust precision motion control of a single and individual cylinder chamber pressure control for better energy saving. With a typical four-way directional

Yao, Bin

343

Combustion Phasing Model for Control of a Gasoline-Ethanol Fueled SI Engine with Variable Valve Timing  

E-Print Network [OSTI]

Combustion Phasing Model for Control of a Gasoline-Ethanol Fueled SI Engine with Variable Valve engine efficiency. Fuel-flexible engines permit the increased use of ethanol-gasoline blends. Ethanol points across the engine operating range for four blends of gasoline and ethanol. I. INTRODUCTION Fuel

344

High-speed and bi-stable electrolysis-bubble actuated planar micro gate valves are demonstrated in this paper.  

E-Print Network [OSTI]

SUMMARY High-speed and bi-stable electrolysis-bubble actuated planar micro gate valves are demonstrated in this paper. The speed of previous low power planar microvalves was limited by the bubble collapse process. In addition bi-stability was unreliable. In this work, surface tension is used

Liepmann, Dorian

345

2007-2009 Power Rate Adjustments (pbl/rates)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Function Review (PFR) Firstgov FY 2007 2009 Power Rate Adjustments BPA's 2007-2009 Wholesale Power Rate Schedules and General Rate Schedule Provisions (GRSPs) took effect on...

346

OpenEI - rates  

Open Energy Info (EERE)

U.S. Electric Utility U.S. Electric Utility Companies and Rates: Look-up by Zipcode (Feb 2011) http://en.openei.org/datasets/node/899 This dataset, compiled by NREL and Ventyx, provides average residential, commercial and industrial electricity rates by zip code for both investor owned utilities (IOU) and non-investor owned utilities. Note: the file includes average rates for each utility, but not the detailed rate structure data found in the database available via the zip-code look-up feature on the OpenEI Utilities page (http://en.openei.org/wiki/Gateway:Utilities). The data was released by NREL/Ventyx in February 2011.

347

Water Rate Escalations  

Broader source: Energy.gov [DOE]

Federal agencies need accurate water cost escalation rates to perform life cycle cost analyses for water efficiency projects to meet Executive Order 13514 and Energy Independence and Security Act...

348

Before a Rate Case  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

is made up of two processes. The first part of the IBR is the Integrated Program Review (IPR), which will address proposed program costs prior to their inclusion in a rate case,...

349

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted "advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202. ...

2002-04-15T23:59:59.000Z

350

Tiered Rate Methodology  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rate Period limit. This 23 exception is limited for the duration of this TRM to the first ten requesting utilities that 24 BP-12-A-03 Section 4 Page 46 meet the size threshold and...

351

Stocking Rate Decisions  

E-Print Network [OSTI]

to predict potential forage shortfalls, determine the im- pact of the decision on finances and other ranch re- sources, and make any necessary adjustments before the forage resource is harmed or financial problems occur. Through adequate planning and periodic... rates with limited knowledge of future forage and market conditions. But they can use past records, experience and range surveys to make realistic projections of forage and market conditions (Figure 3). Then, the planned stock- ing rate should...

White, Larry D.; McGinty, Allan

1999-02-15T23:59:59.000Z

352

On Thermonuclear Reaction Rates  

E-Print Network [OSTI]

Nuclear reactions govern major aspects of the chemical evolution od galaxies and stars. Analytic study of the reaction rates and reaction probability integrals is attempted here. Exact expressions for the reaction rates and reaction probability integrals for nuclear reactions in the case of nonresonant, modified nonresonant, screened nonresonant and resonant cases are given. These are expressed in terms of H-functions, G-functions and in computable series forms. Computational aspects are also discussed.

H. J. Haubold; A. M. Mathai

1996-12-02T23:59:59.000Z

353

Cat Heart Rate Monitoring  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Cat Heart Rate Monitoring Cat Heart Rate Monitoring Name: Shakti Status: student Grade: 9-12 Location: TX Country: USA Date: Summer 2010 Question: What is the best way to find a cat's heart rate using a stethoscope? Because I have tried to hear their heart beat but their purring is all I can hear. If I shouldn't use a stethoscope, then what should I use? Replies: Hi Shakti! If you want to use a stethoscope, the trick is to get your cat to stop purring. Two good ways that I have found to help stop the purring 1. Cover their nose (generally cats don't like this and will stop purring) or 2. Put on the tap to drip or lightly stream water (also, they generally don't like this and will stop purring). Alternatively, you can get their heart rate from feeling their pulse. A good place to try to feel a pulse is right where the leg attaches to the abdomen - in an area called the inguinal region. Now granted there are some heart conditions that will cause an animals pulse and their heart rates don't match up, and it's hard to feel if you have a fat cat, but it's a good place to try if you are really trying to get a heart rate in a healthy kitty!

354

DOE-SPEC-3019-96; Valve-Regulated Type Lead-Acid Storage Batteries  

Broader source: Energy.gov (indexed) [DOE]

9-96 9-96 August 1996 DOE SPECIFICATION VALVE-REGULATED TYPE LEAD-ACID STORAGE BATTERIES U.S. Department of Energy FSC 6140 Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE96009470 DOE-SPEC-3019-96 THIS PAGE INTENTIONALLY LEFT BLANK DOE-SPEC-3019-96 iii FOREWORD 1. Use of this purchase specification is not mandatory. User should review the document and

355

Electron-electron interaction, weak localization and spin valve effect in vertical-transport graphene devices  

SciTech Connect (OSTI)

We fabricated a vertical structure device, in which graphene is sandwiched between two asymmetric ferromagnetic electrodes. The measurements of electron and spin transport were performed across the combined channels containing the vertical and horizontal components. The presence of electron-electron interaction (EEI) was found not only at low temperatures but also at moderate temperatures up to ?120?K, and EEI dominates over weak localization (WL) with and without applying magnetic fields perpendicular to the sample plane. Moreover, spin valve effect was observed when magnetic filed is swept at the direction parallel to the sample surface. We attribute the EEI and WL surviving at a relatively high temperature to the effective suppress of phonon scattering in the vertical device structure. The findings open a way for studying quantum correlation at relatively high temperature.

Long, Mingsheng; Gong, Youpin; Wei, Xiangfei; Zhu, Chao; Xu, Jianbao; Liu, Ping; Guo, Yufen; Li, Weiwei; Liu, Liwei, E-mail: lwliu2007@sinano.ac.cn [Key Laboratory of Nanodevices and Applications-CAS and Collaborative Innovation Center of Suzhou Nano Science and Technology, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences (CAS), Suzhou 215123 (China); Liu, Guangtong [Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China)

2014-04-14T23:59:59.000Z

356

Spin-dependent thermal and electrical transport in a spin-valve system  

SciTech Connect (OSTI)

Within the framework of Bu{close_quotes}ttiker{close_quote}s gauge invariant and charge conservation dc transport theory, the spin-dependent thermal and electrical transport in a ferromagnet-insulator-ferromagnet tunnel junction is investigated at finite bias voltage and finite temperature. It is observed that the relative orientations of magnetizations in the two ferromagnetic (FM) electrodes as well as temperature have remarkable effects on the differential conductance, thermopower, Peltier effect, and thermal conductivity. At low temperature the quantum resonant tunneling is predominant, leading to the deviation of classical transport theory, while the transport of electrons are crucially governed by thermal processes at high temperature. The so-called spin-valve phenomenon is clearly uncovered for both the differential conductance and the thermal conductivity at low temperature. The Wiedemann-Franz law is examined, and the inelastic tunneling spectroscopy is also discussed. Our findings are expected to be measured in the near future.

Wang, Zheng-Chuan; Su, Gang; Gao, Song

2001-06-01T23:59:59.000Z

357

Thermal engineering of non-local resistance in lateral spin valves  

SciTech Connect (OSTI)

We study the non-local spin transport in Permalloy/Cu lateral spin valves (LSVs) fabricated on thermally oxidized Si and MgO substrates. While these LSVs show the same magnitude of spin signals, significant substrate dependence of the baseline resistance was observed. The baseline resistance shows much weaker dependence on the inter-electrode distance than that of the spin transport observed in the Cu wires. A simple analysis of voltage-current characteristics in the baseline resistance indicates the observed result can be explained by a combination of the Peltier and Seebeck effects at the injector and detector junctions, suggesting the usage of high thermal conductivity substrate (or under-layer) is effective to reduce the baseline resistance.

Kasai, S., E-mail: KASAI.Shinya@nims.go.jp; Takahashi, Y. K. [National Institute for Materials Science (NIMS), 1-2-1 Sengen, Tsukuba 305-0047 (Japan); Hirayama, S.; Mitani, S.; Hono, K. [National Institute for Materials Science (NIMS), 1-2-1 Sengen, Tsukuba 305-0047 (Japan); Graduate School of Pure and Applied Sciences, University of Tsukuba, Tsukuba 305-0006 (Japan); Adachi, H.; Ieda, J.; Maekawa, S. [Advanced Science Research Center, Japan Atomic Energy Agency, Tokai 319-1195 (Japan); CREST, Japan Science and Technology Agency, Sanbancho, Tokyo 102-0075 (Japan)

2014-04-21T23:59:59.000Z

358

October 2001 - September 2006 Wholesale Power Rates (rates/previous...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

October 2001 - September 2006 The 2002 Wholesale Power Rate Schedules (base rates) for the FY 2002-2006 rate period were originally established in May 2000 during the WP-02 Rate...

359

Upper Great Plains Rates information  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rates and Repayment Services Rates and Repayment Services Rates 2010 Firm Power Rate (effective January 1, 2010) Rate Adjustments 2010 Firm Power Rate Adjustment 2009 Firm Power Rate Adjustment IS Rate Adjustments Rate Adjustment Process Rate Orders Signed, December 23, 2009 (16kb pdf) Announcements Firm Electric Service Customer Letter - Preliminary Review of Drought Adder Component, June 27, 2013 (74kb pdf) Customer Letter - Final Notice of Drought Adder Component, October 2, 2013 (68kb pdf) Integrated System (IS) Rates 2014 IS Rates Customer Information Meeting Presentation, October 15, 2013 (611kb pdf) Customer Letter - Notification of 2014 Rates, September 13, 2013 (160kb pdf) 2014 Transmission and Ancillary Services Rate Calculation and 2012 Rate True-up Calculation (4.9mb pdf) 2013 IS Rates

360

BCP Annual Rate Process  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2013 BCP Annual Rate Process 2013 BCP Annual Rate Process Informal Process Rate Activity Schedule (doc) Informal Customer Meeting Thursday March 6, 2013 at 10:30 A.M. Conf Rms 3&4 Informal Customer Meeting Presentation (Pdf) PRS Executive Summary (Mar 07, 2013) (Pdf) FY2014 Final Ten Year Operating Plan PRS Executive Summary (PDF) FORM for Foreign Visits (doc) Formal Process Initial Federal Register Notice (pdf) Public Information Forum March 27,2013 at 10:30 A.M. Conf Rms3&4 Customer Meeting Presentation PIF Presentation (PPT) Presentation Details (pdf) Reclamation Fund Status Report PIF PRS Executive Summary (pdf) PIF Transcripts (PDF) Visitor Center Cost Analysis Questions - Responses Public Comment Forum April 10, 2013 at 10:30 A.M. Conf Rms3&4 PCF Transcripts Customer Letters

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Multiple System Rate Process  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DSW Multiple System Transmission Rate Process DSW Multiple System Transmission Rate Process Federal Register Notice Withdrawing Rate Proposal (PDF) Formal Process Extension Federal Register Notice (PDF) Customer Savings Under Various MSTR (XLS) Public Information Forum March 29, 2005 Customer Meeting Overview (Power Point) Customer Meeting Overview (PDF) Customer Meeting Transcript (PDF) Public Comment Forum April 6, 2005 Customer Meeting Transcript (PDF) Response Letter 5-17-05 (PDF) Customer Letters Tonopah ID-5/25/05 (PDF) APS-5/26/05 (PDF) SRP-5/27/05 (PDF) RSLynch-6/1/05 (PDF) KRSaline-6/1/05 (PDF) Formal Process Federal Register Notice (Word) Federal Register Notice (PDF) Brochure (Word) Appendices to Brochure: A B C D E1 E2 F1 F2 GH Public Information Forum July 14, 2004 Customer Meeting Overview (Power Point)

362

Obsidian Hydration Rates  

Science Journals Connector (OSTI)

...OBSIDIAN HYDRATION RATE FOR KLAMATH BASIN OF CALIFORNIA AND OREGON...as the material is excreted, falls through the air, and dries...Friedman. Table 1 presents two new groups of hydra-tion readings for...the true age is believed to fall (3). The Snaketown age is...

Clement W. Meighan

1970-10-02T23:59:59.000Z

363

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2002-03-04T23:59:59.000Z

364

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

1999-10-25T23:59:59.000Z

365

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted"advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2002-12-23T23:59:59.000Z

366

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19067-1612. ...

1997-04-07T23:59:59.000Z

367

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements wilt be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2003-09-15T23:59:59.000Z

368

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted"advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2002-03-25T23:59:59.000Z

369

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

1999-08-16T23:59:59.000Z

370

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2000-06-12T23:59:59.000Z

371

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted"advertisements wilt be classified by the chemical field designated by the members, if not designated, placement will be determined by the first word of the text submitted. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2002-05-27T23:59:59.000Z

372

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Koad, Suite 202, Wayne, PA 19087-1612. ...

1998-04-20T23:59:59.000Z

373

The analysis and specification of large high-pressure, high-temperature valves for combustion turbine protection in second-generation PFB power plants: Topical report  

SciTech Connect (OSTI)

The purpose of this study was to provide a specification for the high-pressure/high-temperature valves for turbine overspeed protection in a commercial-scale second-generation pressurized fluidized bed combustion (PFBC) power plant. In the event of a loss of external (generator) load, the gas turbine rapidly accelerates from its normal operating speed. Protection from excessive overspeed can be maintained by actuation of fuel isolation and air bypass valves. A design specification for these valves was developed by analyses of the turbine/compressor interaction during a loss of load and analyses of pressure and flow transients during operation of the overspeed protection valves. The basis for these analyses was the Phase 1 plant conceptual design prepared in 1987.

Not Available

1994-08-01T23:59:59.000Z

374

Temperature dependent nucleation, propagation, and annihilation of domain walls in all-perpendicular spin-valve nanopillars  

SciTech Connect (OSTI)

We present a study of the temperature dependence of the switching fields in Co/Ni-based perpendicularly magnetized spin-valves. While magnetization reversal of all-perpendicular Co/Ni spin valves at ambient temperatures is typically marked by a single sharp step change in resistance, low temperature measurements can reveal a series of resistance steps, consistent with non-uniform magnetization configurations. We propose a model that consists of domain nucleation, propagation, and annihilation to explain the temperature dependence of the switching fields. Interestingly, low temperature (<30?K) step changes in resistance that we associate with domain nucleation have a bimodal switching field and resistance step distribution, attributable to two competing nucleation pathways.

Gopman, D. B., E-mail: daniel.gopman@physics.nyu.edu; Kent, A. D. [Department of Physics, New York University, New York, New York 10003 (United States); Bedau, D. [Department of Physics, New York University, New York, New York 10003 (United States); HGST San Jose Research Center, San Jose, California 95135 (United States); Mangin, S. [Institut Jean Lamour, UMR CNRS 7198 Université de Lorraine, Nancy, France 54506 (France); Fullerton, E. E. [CMRR, University of California at San Diego, La Jolla, California 92093 (United States); Katine, J. A. [HGST San Jose Research Center, San Jose, California 95135 (United States)

2014-03-21T23:59:59.000Z

375

Relevance of valve overlap for meeting Euro 5 soot emissions requirements during load transient process in heavy duty diesel engines  

Science Journals Connector (OSTI)

This work describes the influence on performance and soot emissions of using different valve overlap camshafts during load transient processes in a heavy duty (HD) diesel engine equipped with a variable geometry turbine (VGT) in its turbocharger and a selective catalyst reactor (SCR) in the exhaust line. Based on the results of experiments and calculations, in this paper a description is given of how the valve timing affects the instantaneous exhaust and intake pressure, the short-circuit of the air mass flow, the prejudicial backflows, the performance of the turbine and hence the general performance and pollutant emissions of a VGT equipped HD diesel engine during a transient process. The paper concludes that very low or no overlap is imperative if a VGT is used to meet forthcoming pollutant emissions restrictions and to improve the transient response of HD turbocharged diesel engines.

J. Galindo; J.R. Serrano; F. Vera; C. Cervello; M. Lejeune

2006-01-01T23:59:59.000Z

376

Rail Coal Transportation Rates  

U.S. Energy Information Administration (EIA) Indexed Site

reports reports Coal Transportation Rates to the Electric Power Sector With Data through 2010 | Release Date: November 16, 2012 | Next Release Date: December 2013 | Correction Previous editions Year: 2011 2004 Go Figure 1. Deliveries from major coal basins to electric power plants by rail, 2010 Background In this latest release of Coal Transportation Rates to the Electric Power Sector, the U.S. Energy Information Administration (EIA) significantly expands upon prior versions of this report with the incorporation of new EIA survey data. Figure 1. Percent of total U.S. rail shipments represented in data figure data Previously, EIA relied solely on data from the U.S. Surface Transportation Board (STB), specifically their confidential Carload Waybill Sample. While valuable, due to the statistical nature of the Waybill data,

377

Plant Tumor Growth Rates  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Plant Tumor Growth Rates Plant Tumor Growth Rates Name: Gina and Maria Location: N/A Country: N/A Date: N/A Question: We are doing a science fair project on if B. Carotene, Green tea, and Grape Seed Extract helps plants against the crown gall disease. We injected sunflowers with agrobacterium tum. one week ago (Sun. Feb. 27, 2000). Our questions is how long will it take for the tumors to grow? We scratched the surface of the stems and injected the agrobacterium in the wound. Also which do you think, in your opinion, will do the best, if any? Our science fair is April 13, do you think we'll have growth before then, atleast enough time to do our conclusion and results? Thank you, any information you forward will be very helpful. Replies: Sunflowers form galls relatively quickly. I usually get them in two weeks at least. Good luck.

378

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Jan. '99 to Feb. '99: -1.7% Feb. '98 to Feb. '99: +19.8% YTD '98 to YTD '99: +15.0% 4,100 4,400 4,700 5,000 5,300 5,600 5,900 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons U.S. Distillate Fuel Sales 2011 2012 2013 Adjusted Growth Rates* Jul '13 to Aug '13: 2.5% Aug '12 to Aug '13: -1.3% YTD '12 to YTD '13: 1.5% 300 400 500 600 700 800 900 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons U.S. Residual Fuel Sales 2011 2012 2013 Adjusted Growth Rates* Jul '13 to Aug '13: -0.8%

379

Gasoline-like Fuel Effects on High-load, Boosted HCCI Combustion Employing Negative Valve Overlap Strategy  

SciTech Connect (OSTI)

In recent years a number of studies have demonstrated that boosted operation combined with external EGR is a path forward for expanding the high load limit of homogeneous charge compression ignition (HCCI) operation with the negative valve overlap (NVO) valve strategy. However, the effects of fuel composition with this strategy have not been fully explored. In this study boosted HCCI combustion is investigated in a single-cylinder research engine equipped with direct injection (DI) fueling, cooled external exhaust gas recirculation (EGR), laboratory pressurized intake air, and a fully-variable hydraulic valve actuation (HVA) valve train. Three fuels with significant compositional differences are investigated: regular grade gasoline (RON = 90.2), 30% ethanol-gasoline blend (E30, RON = 100.3), and 24% iso-butanol-gasoline blend (IB24, RON = 96.6). Results include engine loads from 350 to 800 kPa IMEPg for all fuels at three engine speeds 1600, 2000, and 2500 rpm. All operating conditions achieved thermal efficiency (gross indicated efficiency) between 38 and 47%, low NOX emissions ( 0.1 g/kWh), and high combustion efficiency ( 96.5%). Detailed sweeps of intake manifold pressure (atmospheric to 250 kPaa), EGR (0 25% EGR), and injection timing are conducted to identify fuel-specific effects. The major finding of this study is that while significant fuel compositional differences exist, in boosted HCCI operation only minor changes in operational conditions are required to achieve comparable operation for all fuels. In boosted HCCI operation all fuels were able to achieve matched load-speed operation, whereas in conventional SI operation the fuel-specific knock differences resulted in significant differences in the operable load-speed space. Although all fuels were operable in boosted HCCI, the respective air handling requirements are also discussed, including an analysis of the demanded turbocharger efficiency.

Kalaskar, Vickey B [ORNL] [ORNL; Szybist, James P [ORNL] [ORNL; Splitter, Derek A [ORNL] [ORNL

2014-01-01T23:59:59.000Z

380

Adjusted Growth Rates* Jan.  

U.S. Energy Information Administration (EIA) Indexed Site

Adjusted Adjusted Growth Rates* Jan. '99 to Feb. '99: -1.7% Feb. '98 to Feb. '99: +19.8% YTD '98 to YTD '99: +15.0% U.S. Distillate Fuel Sales 3,000 3,500 4,000 4,500 5,000 5,500 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1998 1999 2000 Adjusted Growth Rates* Dec '99 to Jan '00: -7.4% Jan '99 to Jan '00: -0.1% YTD '99 to YTD '00: -0.1% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1998 1999 2000 Adjusted Growth Rates* Dec '99 to Jan '00: -16.8% Jan '99 to Jan '00: -3.2% YTD '99 to YTD '00: -3.2% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1998 1999 2000 Adjusted Growth Rates* Dec '99 to Jan '00: -9.3% Jan '99 to Jan '00: +3.5% YTD '99 to YTD '00: +3.5% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Rate Adjustments and Public Involvement  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rate Adjustments and Public Involvement Documents Rate Adjustments and Public Involvement Documents CRSP Transmission 9/16/2013 WAPA-161 FRN, CRSP transmission and ancillary services rates extension Letter announcing two-year extension to CRSP transmission and ancillary services rates Letter announcing revised CRSP transmission rates for FY 2014 Accompanying calculation table for FY 2014 CRSP transmission rate letter Letter announcing revised CRSP transmission rates for FY 2013 Letter announcing revised CRSP transmission rates for FY 2012 Letter announcing revised CRSP transmission rates for FY 2011 Letter announcing revised CRSP transmission rates for FY 2010 SLCA/IP 9/16/2013 WAPA-161 FRN, SLCA/IP firm power rate extension Letter announcing two-year extension to SLCA/IP firm power rate SLCA/IP Tentative Rate Adjustment Schedule

382

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

June '99 to July '99: -5.4% June '99 to July '99: -5.4% July '98 to July '99: +3.3% YTD '98 to YTD '99: +6.3% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* June '99 to July '99: -0.5% July '98 to July '99: -0.4% YTD '98 to YTD '99: +1.1% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* June '99 to July '99: +0.5% July '98 to July '99: +1.0% YTD '98 to YTD '99: -0.3% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* June '99 to July '99: +1.5% July '98 to July '99: +10.2% YTD '98 to YTD '99: +7.2%

383

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Nov '99 to Dec '99: +5.3% Nov '99 to Dec '99: +5.3% Dec '98 to Dec '99: +8.7% YTD '98 to YTD '99: +5.0% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Nov '99 to Dec '99: +6.0% Dec '98 to Dec '99: +4.5% YTD '98 to YTD '99: +1.3% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Nov '99 to Dec '99: +2.4% Dec '98 to Dec '99: +3.0% YTD '98 to YTD '99: +0.9% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Nov '99 to Dec '99: +32.3% Dec '98 to Dec '99: +2.0% YTD '98 to YTD '99: +5.5%

384

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

July '99 to Aug. '99: +4.7% July '99 to Aug. '99: +4.7% Aug. '98 to Aug. '99: +1.3% YTD '98 to YTD '99: +4.7% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* July '99 to Aug. '99: -1.9% Aug. '98 to Aug. '99: -0.4% YTD '98 to YTD '99: +0.9% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* July '99 to Aug. '99: -0.1% Aug. '98 to Aug. '99: -1.4% YTD '98 to YTD '99: -0.7% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* July '99 to Aug. '99: +22.3% Aug. '98 to Aug. '99: +21.1%

385

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Aug '99 to Sep '99: +4.9% Aug '99 to Sep '99: +4.9% Sep '98 to Sep '99: +4.7% YTD '98 to YTD '99: +4.7% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Aug '99 to Sep '99: -2.4% Sep '98 to Sep '99: +0.4% YTD '98 to YTD '99: +1.3% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Aug '99 to Sep '99: -2.1% Sep '98 to Sep '99: +4.6% YTD '98 to YTD '99: 0.0% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Aug '99 to Sep '99: +7.3% Sep '98 to Sep '99: +8.4% YTD '98 to YTD '99: +8.3%

386

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Oct '99 to Nov '99: +0.1% Oct '99 to Nov '99: +0.1% Nov '98 to Nov '99: +5.5% YTD '98 to YTD '99: +4.5% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Oct '99 to Nov '99: -0.7% Nov '98 to Nov '99: +1.7% YTD '98 to YTD '99: +1.1% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Oct '99 to Nov '99: +2.5% Nov '98 to Nov '99: +6.0% YTD '98 to YTD '99: +0.8% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Oct '99 to Nov '99: +9.7% Nov '98 to Nov '99: +2.2% YTD '98 to YTD '99: +6.2%

387

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Sep '99 to Oct '99: +3.9% Sep '99 to Oct '99: +3.9% Oct '98 to Oct '99: +2.3% YTD '98 to YTD '99: +4.4% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Sep '99 to Oct '99: -0.2% Oct '98 to Oct '99: -0.9% YTD '98 to YTD '99: +1.0% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Sep '99 to Oct '99: -1.9% Oct '98 to Oct '99: -0.7% YTD '98 to YTD '99: +0.4% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Sep '99 to Oct '99: -2.1% Oct '98 to Oct '99: -6.4% YTD '98 to YTD '99: +6.6%

388

Transportation Rates For Fishery Products  

E-Print Network [OSTI]

express (Railway Express Agency), and motor carriers. Air transporta- tion and water transportation 2 Rail-freight rates 2 Rail-express rates 3 Motor-carrier rates 3 Protective-service charges 4 used in sample 7 2. Rail-express rate index: Routes used in sample 7 3. Motor-carrier rate index

389

October 1996 - September 2001 Wholesale Power Rates (rates/previous...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

affecting a specific power purchase. For more specific information see: 1996 Final Wholesale Power and Transmission Rate Schedules: Power Rates (PDF, 84 pages, 188 kb) Ancillary...

390

Pressure and flow characteristics of restrictive flow orifice devices.  

SciTech Connect (OSTI)

A Restrictive Flow Orifice (RFO) can be used to enhance the safe design of a pressure system in several ways. Pressure systems frequently incorporate a regulator and relief valve to protect the downstream equipment from accidental overpressure caused by regulator failure. Analysis frequently shows that in cases of high-flow regulator failure, the downstream pressure may rise significantly above the set pressure of the relief valve. This is due to limited flow capacity of the relief valve. A different regulator or relief valve may need to be selected. A more economical solution to this problem is to use an RFO to limit the maximum system flow to acceptable limits within the flow capacity of the relief valve, thereby enhancing the overpressure protection of laboratory equipment. An RFO can also be used to limit the uncontrolled release of system fluid (gas or liquid) upon component or line failure. As an example, potential asphyxiation hazards resultant from the release of large volumes of inert gas from a 'house' nitrogen system can be controlled by the use of an RFO. This report describes a versatile new Sandia-designed RFO available from the Swagelok Company and specifies the gas flow characteristics of this device. Two sizes, 0.010 and 0.020 inch diameter RFOs are available. These sizes will allow enhanced safety for many common applications. This new RFO design are now commercially available and provide advantages over existing RFOs: a high pressure rating (6600 psig); flow through the RFO is equal for either forward or reverse directions; they minimize the potential for leakage by incorporating the highest quality threaded connections; and can enhance the safety of pressure systems.

Shrouf, Roger D.

2003-06-01T23:59:59.000Z

391

Tier 2 Vintage Rate Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

4 Tier 2 Rate Alternatives Tier 2 Rate Alternatives Load Growth Rate BPA commits to meet Load Following customers' load growth placed on BPA for the term of the commitment period...

392

Energy saving dispatch with complex constraints: Prohibited zones, valve point effect and carbon tax  

Science Journals Connector (OSTI)

Abstract This paper presents an energy saving dispatch (ESD) strategy, based upon the optimal power flow (OPF) model, considering complex constraints, such as prohibited operating zones, the valve point effect of generation units and the carbon tax of a power grid. With these constraints, the OPF problem becomes more difficult to resolve, and it needs to be dealt with by a more accurate and reliable optimization algorithm. In this paper, an improved group search optimizer (GSO), namely the group search optimizer with intraspecific competition and lévy walk (GSOICLW), is adopted to tackle this problem. It is more biologically realistic than GSO, in which intraspecific competition (IC) and lévy walk (LW) are incorporated in the original GSO. IC and LW of GSOICLW are capable of achieving superior balance between global and local searching, i.e., GSOICLW maintains GSO’s global searching ability to avoid entrapping in local optima while improves local searching near the global optima. The standard IEEE 30-bus power system is employed to carry out the simulation study to test GSOICLW, which is subsequently compared with other evolutionary algorithms (EAs). Simulation results show that GSOICLW outperforms other \\{EAs\\} used in this research and also provides accurate and reliable optimization results in dealing with the OPF problem for ESD.

Y.Z. Li; M.S. Li; Q.H. Wu

2014-01-01T23:59:59.000Z

393

Surface damage on the mating interior and exterior pistons used in a marine exhaust valve  

Science Journals Connector (OSTI)

Abstract The wear damage occurred on the two mating pistons, interior piston and exterior piston used for a marine exhaust valve. Visual and SEM observations indicate that the heavy wear marks and wear strips with flaky spalling occurred on the contact surfaces of both pistons. The primary failure mode is the adhesive wear accompanied by little fatigue wear. Metallurgical observations reveal that a white etching layer (WEL) is presented beneath the seriously worn surfaces. XRD analysis indicates that the amount of austenite on the unworn or the lightly worn surfaces of both pistons is in a high level. During operation, the metastable austenite would transform to the martensite under the friction stress, which results in a volume expansion. The clearance between mating pistons would become small to make the friction force on the contact surfaces increase. And the increased friction force induced the concentrated frictional heating. Inadequate lubrication oil cannot bring frictional energy away in time so that the located surface temperature would exceed critical temperature (Ac3). This temperature rise is high enough for austenitization and under such high temperature, the instantaneous hardness of located contact surfaces is low to lead to the occurrence of adhesion wear. Subsequent ? ? ?? transformation would occur as the bulk of the piston rapidly conducts heat away from the piston surfaces to form a WEL on the seriously worn surface. The micro-crack formation inside the WEL and subsequent propagating would lead to the occurrence of spalling.

Zhi-wei Yu; Xiao-lei Xu; Xing-jun Niu; Tao Cai

2013-01-01T23:59:59.000Z

394

Plasma Adiabatic Lapse Rate  

Science Journals Connector (OSTI)

The plasma analog of an adiabatic lapse rate (or temperature variation with height) in atmospheric physics is obtained. A new source of plasma temperature gradient in a binary ion species mixture is found that is proportional to the concentration gradient ??? and difference in average ionization states Z2-Z1. Application to inertial-confinement-fusion implosions indicates a potentially strong effect in plastic (CH) ablators that is not modeled with mainline (single-fluid) simulations. An associated plasma thermodiffusion coefficient is derived, and charge-state diffusion in a single-species plasma is also predicted.

Peter Amendt; Claudio Bellei; Scott Wilks

2012-08-16T23:59:59.000Z

395

Rate types for stream programs  

Science Journals Connector (OSTI)

We introduce RATE TYPES, a novel type system to reason about and optimize data-intensive programs. Built around stream languages, RATE TYPES performs static quantitative reasoning about stream rates -- the frequency of data items in a stream being ... Keywords: data processing rates, data throughput, performance reasoning, stream programming, type systems

Thomas W. Bartenstein, Yu David Liu

2014-10-01T23:59:59.000Z

396

electric rates | OpenEI  

Open Energy Info (EERE)

electric rates electric rates Dataset Summary Description This dataset, compiled by NREL and Ventyx, provides average residential, commercial and industrial electricity rates by zip code for both investor owned utilities (IOU) and non-investor owned utilities. Note: the file includes average rates for each utility, but not the detailed rate structure data found in the database available via the zip-code look-up feature on the OpenEI Utilities page (http://en.openei.org/wiki/Gateway:Utilities). The data was released by NREL/Ventyx in February 2011. Source NREL and Ventyx Date Released February 24th, 2012 (2 years ago) Date Updated Unknown Keywords electric rates rates US utilities Data text/csv icon IOU rates by zipcode (csv, 1.7 MiB) text/csv icon Non-IOU rates by zipcode (csv, 2.1 MiB)

397

Rate Schedules | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Rate Schedules Rate Schedules Rate Schedules One of the major responsibilities of Southeastern is to design, formulate, and justify rate schedules. Repayment studies prepared by the agency determine revenue requirements and appropriate rate levels and these studies for each of Southeastern's four power marketing systems are updated annually. They demonstrate the adequacy of the rates for each system. Rates are considered to be adequate when revenues are sufficient to repay all costs associated with power production and transmission costs, which include the amortization of the Federal investment allocated to power. Latest Rate Schedules October 1, 2012 ALA-1-N Wholesale Power Rate Schedule Area: PowerSouth Energy Cooperative System: Georgia-Alabama-South Carolina October 1, 2012

398

2007-2009 Power Rates Quarterly Updates (pbl/rates)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

(PFR) Firstgov FY 2007 2009 Power Rates Quarterly Updates In BPAs 2007-2009 Wholesale Power Rate Case (WP-07), BPA agreed that it would post reports about BPAs power...

399

WP-07 Power Rate Case (rates/ratecases)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rate Cases Financial Choices (2003-06) Power Function Review (PFR) Firstgov 2007 Wholesale Power (WP-07) Rate Case Related Links: Power Function Review (PFR) On July 17, 2006,...

400

National Utility Rate Database: Preprint  

SciTech Connect (OSTI)

When modeling solar energy technologies and other distributed energy systems, using high-quality expansive electricity rates is essential. The National Renewable Energy Laboratory (NREL) developed a utility rate platform for entering, storing, updating, and accessing a large collection of utility rates from around the United States. This utility rate platform lives on the Open Energy Information (OpenEI) website, OpenEI.org, allowing the data to be programmatically accessed from a web browser, using an application programming interface (API). The semantic-based utility rate platform currently has record of 1,885 utility rates and covers over 85% of the electricity consumption in the United States.

Ong, S.; McKeel, R.

2012-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Rating the NRF's rating system Michael I. Cherry  

E-Print Network [OSTI]

the NRF's raison d'être--thetrainingofhigh-qualityresearch manpower. The progress of the rating systemRating the NRF's rating system Michael I. Cherry a* and Mark J. Gibbons b T HE LATEST REVIEW OF THE NATIONAL Research Foundation (NRF), chaired by Wieland Gevers, and released surreptitiously

Wagner, Stephan

402

Cryogenic Safety Training  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

fluids at the NHMFL is the dewar. The dewar is designed with a vacuum jacket for insulation and pressure relief valves to protect against over- pressurization. Vacuum...

403

SCHOOL OF MEDICINE TELECOMMUNICATIONS RATE  

E-Print Network [OSTI]

SCHOOL OF MEDICINE TELECOMMUNICATIONS RATE BACKGROUND The University recently the desktop phone service costs back to individual units/departments by creating a telecommunications rate in the Other Expenses category of the budget as a "Telecommunications Charge". NOTE- direct charging

Straight, Aaron

404

2007 Wholesale Power Rate Schedules : 2007 General Rate Schedule Provisions.  

SciTech Connect (OSTI)

This schedule is available for the contract purchase of Firm Power to be used within the Pacific Northwest (PNW). Priority Firm (PF) Power may be purchased by public bodies, cooperatives, and Federal agencies for resale to ultimate consumers, for direct consumption, and for Construction, Test and Start-Up, and Station Service. Rates in this schedule are in effect beginning October 1, 2006, and apply to purchases under requirements Firm Power sales contracts for a three-year period. The Slice Product is only available for public bodies and cooperatives who have signed Slice contracts for the FY 2002-2011 period. Utilities participating in the Residential Exchange Program (REP) under Section 5(c) of the Northwest Power Act may purchase Priority Firm Power pursuant to the Residential Exchange Program. Rates under contracts that contain charges that escalate based on BPA's Priority Firm Power rates shall be based on the three-year rates listed in this rate schedule in addition to applicable transmission charges. This rate schedule supersedes the PF-02 rate schedule, which went into effect October 1, 2001. Sales under the PF-07 rate schedule are subject to BPA's 2007 General Rate Schedule Provisions (2007 GRSPs). Products available under this rate schedule are defined in the 2007 GRSPs. For sales under this rate schedule, bills shall be rendered and payments due pursuant to BPA's 2007 GRSPs and billing process.

United States. Bonneville Power Administration.

2006-11-01T23:59:59.000Z

405

Commercial Building Asset Rating Program  

Broader source: Energy.gov [DOE]

Slides from a Commercial Building Initiative webinar outlining the Commercial Building Asset Rating Program on August 23, 2011.

406

Invariant formulation for dispersed transverse isotropy in aortic heart valves: An efficient means for modeling fiber splay  

SciTech Connect (OSTI)

Most soft tissues possess an oriented architecture of collagen fiber bundles, conferring both anisotropy and nonlinearity to their elastic behavior. Transverse isotropy has often been assumed for a subset of these tissues that have a single macroscopically-identifiable preferred fiber direction. Micro-structural studies, however, suggest that, in some tissues, collagen fibers are approximately normally distributed about a mean preferred fiber direction. Structural constitutive equations that account for this dispersion of fibers have been shown to capture the mechanical complexity of these tissues quite well. Such descriptions, however, are computationally cumbersome for two-dimensional (2D) fiber distributions, let alone for fully three-dimensional (3D) fiber populations. In this paper, we develop a new constitutive law for such tissues, based on a novel invariant theory for dispersed transverse isotropy. The invariant theory is based on a novel closed-form ''splay invariant'' that can easily handle 3D fiber populations, and that only requires a single parameter in the 2D case. The model is polyconvex and fits biaxial data for aortic valve tissue as accurately as the standard structural model. Modification of the fiber stress-strain law requires no re-formulation of the constitutive tangent matrix, making the model flexible for different types of soft tissues. Most importantly, the model is computationally expedient in a finite-element analysis, demonstrated by modeling a bioprosthetic heart valve.

Freed, Alan D.; Einstein, Daniel R.; Vesely, Ivan

2005-11-01T23:59:59.000Z

407

Development and modification of a single overhead camshaft 4-valve 4-stroke 135 cc formula varsity race car engine  

Science Journals Connector (OSTI)

The engine that was chosen to be developed and modified is Yamaha LC 135 Single Overhead Camshaft (SOHC) 4-valve 4-stroke 135cc liquid-cooled engine. The engine selection is based on the specification, rule and regulation in UTeM Formula Varsity 2012 (FV 2012). The engine performance is determined by engine operating characteristics. The engine air flow affects the filtration, intake and exhaust systems. The heat from the engine rejected to the surrounding through the active cooling system which has radiator and fan. The selection of the engine is based on weighted decision matrix which consists of reliability, operating and maintenance cost, fuel consumption and weight. The score of the matrix is formulated based on relative weighted factor among the selections. It been compared between Yamaha LC 135 Single Overhead Camshaft (SOHC) 4-valve 4-stroke 135cc liquid-cooled engine, Honda Wave 125 X Air Cooled, 4 Cycle Engine Overhead Camshaft (OHC) and Suzuki Shogun RR 4 stroke air cooled Single Overhead Camshaft (SOHC). The modification is applied to the engine through the simulation and tuning of Capacitor Discharge Ignition (CDI).

M A Abdullah; N Tamaldin; H Rusnandi; T Manoharan; M A Samsir

2013-01-01T23:59:59.000Z

408

Asymptotic Cellular Growth Rate as the Effective Information Utilization Rate  

E-Print Network [OSTI]

We study the average asymptotic growth rate of cells in randomly fluctuating environments. Using a game-theoretic perspective, we show that any response strategy has an asymptotic growth rate, which is the sum of: (i) the maximal growth rate at the worst possible distribution of environments, (ii) relative information between the actual distribution of environments to the worst one, and (iii) information utilization rate which is the information rate of the sensory devices minus the "information dissipation rate", the amount of information not utilized by the cell for growth. In non-stationary environments, the optimal strategy is the time average of the instantaneous optimal strategy and the optimal switching times are evenly spaced in the statistical (Fisher) metric.

Pugatch, Rami; Tlusty, Tsvi

2013-01-01T23:59:59.000Z

409

The Inverted Block Rate:The Inverted Block Rate: An Alternative to Flat Rate BillingAn Alternative to Flat Rate Billing  

E-Print Network [OSTI]

The Inverted Block Rate:The Inverted Block Rate: An Alternative to Flat Rate BillingAn Alternative;Inverted Block RateInverted Block Rate 22 IntroductionIntroduction ·· Modern societies rely on electrical collectionMetering and Rate Models facilitate collection #12;Inverted Block RateInverted Block Rate 33 Rate

Hughes, Larry

410

October 2003 - March 2004 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 - March 2004 (CRAC 5 period) "Monthly Adjusted" Wholesale Power Rates Effective October 2003 - March 2004 (CRAC 5 period) (PDF, 4 pages, 15 kb, corrected December 18, 2003,...

411

April - September 2004 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

4 (CRAC 6 period) "Monthly Adjusted" Wholesale Power Rates Effective April 1 - September 30, 2004 (CRAC 6 period) (PDF, 4 pages, 14 kb, originally posted January 12, 2004;...

412

April - September 2005 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

April - September 2005 (CRAC 8 period) "Monthly Adjusted" Wholesale Power Rates Effective April - September 2005 (CRAC 8 period) (PDF, 3 pages, 108 kb, posted December 17, 2004)...

413

October 2005 - March 2006 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

October 2005 - March 2006 (CRAC 9 period) "Monthly Adjusted" Wholesale Power Rates Effective October 2005 - March 2006 (CRAC 9 period) (PDF, 4 pages, 116 kb, originally posted...

414

LEED for Homes Rating System affordablemarket rate multi-family  

E-Print Network [OSTI]

LEED for Homes Rating System affordablemarket rate multi-family #12;The top 25% of new homes based% REGULATIONS lawbreakers DEGREE OF GREEN MARKET SHIFT typical building practices market leaders innovators the negative impact of buildings on their occupants and on the environment. LEED for Homes categories

Zaferatos, Nicholas C.

415

The Coal Transportation Rate Database  

Gasoline and Diesel Fuel Update (EIA)

Coal Transportation Rate Database (CTRDB) adds new data for 2000 and 2001. The Federal Energy Regulatory Commission's (FERC) Form 580 "interrogatories" are the primary source for...

416

BPA revises oversupply rate proposal  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

oversupply-rate-proposal Sign In About | Careers | Contact | Investors | bpa.gov Search News & Us Expand News & Us Projects & Initiatives Expand Projects & Initiatives...

417

Rapid Relief: A Prefabricated Response  

E-Print Network [OSTI]

the industrial revolution and that with these new tools, progress should occur accordingly. Le Corbusier goes on to explain how ?it is not right that we should produce bad things because of a bad tool; nor is it right that we should waste our energy, our..., potable water, power, medication, sanitation, adequate sheltering, and any form of organizational help? (Cutter and Gall, 2012). All in all, ?FEMA failed to fulfill its responsibilities as the leading coordinating emergency management institution...

Gohmert, Brent Cole

2013-02-06T23:59:59.000Z

418

Materials Science and Engineering B 117 (2005) 5361 Finite element analysis-based design of a fluid-flow control nano-valve  

E-Print Network [OSTI]

of a fluid-flow control nano-valve M. Grujicica,, G. Caoa, B. Pandurangana, W.N. Royb a Department A finite element method-based procedure is developed for the design of molecularly functionalized nano-size devices. The procedure is aimed at the single-walled carbon nano-tubes (SWCNTs) used in the construction

Grujicic, Mica

419

Mechanisms for left ventricular systolic dysfunction in aortic regurgitation: Importance for predicting the functional response to aortic valve replacement  

Science Journals Connector (OSTI)

To test the hypothesis that the combined use of the time-varying distance concept and conventional circumferential stress-shortening relations would elucidate differential mechanisms for left ventricular systolic dysfunction in severe, chronic aortic regurgitation and therefore predict the functional responses to aortic valve replacement, 31 control patients and 37 patients with aortic regurgitation were studied. The studies included micromanometer left ventricular pressure determinations, biplane contrast cineangiograms under control conditions and radionuclide angiograms under control conditions and during methoxamine or nitroprusside infusions with right atrial pacing. The patients with aortic regurgitation were classified into three groups: Group I had normal Emax and stress-shortening relations, Group II had abnormal Emax but normal stress-shortening relations and Group III had abnormal Emax and stress-shortening relations. The left ventricular end-diastolic and end-systolic volumes showed a progressive increase and the ejection fraction showed a progressive decrease from Group I to III; these values differed from those in the control patients (p < 0.001). In Group I, then was a decrease in left ventricular volumes (p < 0.05) but no significant change in ejection fraction (61 ± 7% versus 63 ± 4%) after aortic valve replacement. In contrast, in Group II, reduction in left ventricular volumes (p < 0.01) was associated with an increase in ejection fraction from 50 ± 8% to 64 ± 11% (p < 0.01). Finally, in Group III, reduction in left ventricular volumes (p < 0.05) was associated with a further decrement in ejection fraction from 35 ± 13% to 30 ± 13%. Group I patients had compensated adequately for chronic volume overload. However, Group II had left ventricular dysfunction that was associated with an increase in the left ventricular volume/mass ratio compared with that in the control patients and Group I (p < 0.05 for both), suggesting inadequate hypertrophy and assumption of spherical geometry. Finally, irreversible myocardial dysfunction had supervened in Group III. In conclusion, a combined analysis of left ventricular chamber performance using the time-varying elastance concept and myocardial performance using conventional circumferential stress-shortening relations provides complementary information that elucidates differential mechanisms for left ventricular systolic dysfunction and therefore predicts the functional response to aortic valve replacement.

Mark R. Starling; Marvin M. Kirsh; Daniel G. Montgomery; Milton D. Gross

1991-01-01T23:59:59.000Z

420

RECYCLING RATE STUDY Prepared by  

E-Print Network [OSTI]

NATIONAL RECYCLING RATE STUDY Prepared by: Smith, Bucklin and Associates, Inc. Market Research and Statistics Division Chicago, Illinois July 2003 PRINTED ON RECYCLED PAPER #12;BCI RECYCLING RATE STUDY TABLE ....................................................................................................1 II. METHODOLOGY A. Total Pounds of Lead Recycled from Batteries

Laughlin, Robert B.

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Commercial Building Asset Rating Program  

Broader source: Energy.gov (indexed) [DOE]

1 eere.energy.gov 1 eere.energy.gov Commercial Building Asset Rating Program August 23, 2011 12 p.m. ET, 9 a.m. PT Presenter: Cody Taylor PRE-DECISIONAL Information included in this document is for discussion purposes and does not constitute the final program design. FOR INFORMATION ONLY 2 eere.energy.gov Outline * Goals * Scope & schedule * Guiding principles * Program design issues - Metrics - Rating method - Rating scale - Opportunities for efficiency improvement - Quality assurance Please submit clarifying questions during today's webinar via the Q&A function of Live Meeting. 3 eere.energy.gov National Building Rating Program Goals * Facilitate cost-effective investment in energy efficiency and reduce energy use in the commercial building sector * Establish a national standard for voluntary commercial building asset rating

422

Innovative Rates Program. Final report  

SciTech Connect (OSTI)

Title II of the Energy Conservation and Production Act (ECPA) as amended by the Public Utility Regulatory Policies Act (PURPA) provided financial assistance to state utility regulatory commissions, nonregulated electric utilities, and the Tennessee Valley Authority through the Innovative Rates Program. The financial assistance was to be used to plan or carry out electric utility regulatory rate reform initiatives relating to innovative rate structures that encourage conservation of energy, electric utility efficiency and reduced costs, and equitable rates to consumers. The Federal and local objectives of the project are described. Activities planned and accomplishments are summarized for the following: project management, data collection, utility bill evaluation, billing enclosure/mailing evaluation, media program evaluation, display evaluation, rate study sessions evaluation, speakers bureau evaluation, and individual customer contacts. A timetable/milestone chart and financial information are included. (MHR)

Not Available

1982-06-21T23:59:59.000Z

423

October 2004 - March 2005 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

4 - March 2005 (CRAC 7 period) "Monthly Adjusted" Wholesale Power Rates Effective October 2004 - March 2005 (CRAC 7 period) (PDF, 3 pages, 13 kb, originally posted at 11 a.m. on...

424

April - September 2002 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2 (CRAC 2 period) "Monthly Adjusted" Wholesale Power Rates Effective April - September 2002 (CRAC 2 period) (PDF, 9 kb, posted April 1, 2002) Note: The PDF document above provides...

425

October 2002 - March 2003 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2 - March 2003 (CRAC 3 period) "Monthly Adjusted" Wholesale Power Rates Effective October 2002 - March 2003 (CRAC 3 period) (PDF, 14 kb, posted October 1, 2002) Note: The PDF...

426

April - September 2003 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 (CRAC 4 period) "Monthly Adjusted" Wholesale Power Rates Effective April - September 2003 (CRAC 4 period) (PDF, 3 pages, 74 kb, updated April 8, 2003) Note: The PDF document...

427

October 2001 - March 2002 Power Rates (rates/previous)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

1 - March 2002 (CRAC 1 period) "Monthly Adjusted" Wholesale Power Rates Effective October 2001 - March 2002 (CRAC 1 period) (PDF, 6 kb, updated October 3, 2001, posted October 4,...

428

Closed bore XMR (CBXMR) systems for aortic valve replacement: Investigation of rotating-anode x-ray tube heat loadability  

SciTech Connect (OSTI)

In order to improve the safety and efficacy of percutaneous aortic valve replacement procedures, a closed bore hybrid x-ray/MRI (CBXMR) system is proposed in which an x-ray C-arm will be positioned with its isocenter {approx_equal}1 m from the entrance of a clinical MRI scanner. This system will harness the complementary strengths of both modalities to improve clinical outcome. A key component of the CBXMR system will be a rotating anode x-ray tube to produce high-quality x-ray images. There are challenges in positioning an x-ray tube in the magnetic fringe field of the MRI magnet. Here, the effects of an external magnetic field on x-ray tube induction motors of radiography x-ray tubes and the corresponding reduction of x-ray tube heat loadability are investigated. Anode rotation frequency f{sub anode} was unaffected when the external magnetic field B{sub b} was parallel to the axis of rotation of the anode but decreased when B{sub b} was perpendicular to the axis of rotation. The experimental f{sub anode} values agreed with predicted values to within {+-}3% over a B{sub b} range of 0-30 mT. The MRI fringe field at the proposed location of the x-ray tube mounted on the C-arm ({approx_equal}4 mT) reduced f{sub anode} by only 1%, so x-ray tube heat loadability will not be compromised when using CBXMR systems for percutaneous aortic valve replacement procedures. Eddy current heating power in the rotor due to an MRI fringe field was found to be two orders of magnitude weaker than the heating power produced on the anode due to a fluoroscopic exposure, so eddy current heating had no effect on x-ray tube heat loadability.

Bracken, John A.; Lillaney, Prasheel V.; Fahrig, Rebecca; Rowlands, J. A. [Sunnybrook Health Sciences Center, Department of Medical Biophysics, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada); Department of Radiology, Lucas MRS Center, Stanford University, 1201 Welch Road, Stanford, California 94305-5488 (United States); Sunnybrook Health Sciences Center, Department of Medical Biophysics, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada)

2008-09-15T23:59:59.000Z

429

Positron annihilation rates in materials  

Science Journals Connector (OSTI)

The study of positron annihilation rate is one subject of a relatively new method of material structure analysis â?? positron annihilation spectroscopy. Polyethylene Terephthalate (PET) films have been studied by positron annihilation rate measurement. The correlation between annihilation rates and the PET film thickness was established. Similar studies were carried out for aluminium foils and water. The results give information on the probability of positron annihilation per unit of time and per unit of material thickness that is described by an explicit function of the energy transfer model.

Tran Dai Nghiep; Khuong Thanh Tuan; Ngo Danh Du

2007-01-01T23:59:59.000Z

430

DOE Guidance-Category Rating  

Broader source: Energy.gov (indexed) [DOE]

2010 2010 MEMORANDUM FOR HUMAN RESOURCES DIRECTORS FROM: SARA"iJ. Boku1, DIRECToR OF HUMAN C~TAL MANAGEMENT SUBJECT: GUIDANCE MEMORANDUM #10 CATEGORY RATING The purpose of this memorandum is to establish the Department of Energy's (DOE's) policy for the use of Category Rating. Authorities: Public Law 107-296; Title 5 USC 3319; 5 CFR, Part 337, Subpart C., Presidential Memorandum of May 11, 2010 This guidance is established in accordance with 5 USC 3319, which authorizes Federal Agencies to use alternative rating proced.ures in assessing applicants for employment using category rating and selection procedures, and to ensure consistency in complying with federal regulations contained in the Code of Federal Regulations (CFR), Office of Personnel Management (OPM) and the Department of

431

ARM - Measurement - Radiative heating rate  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

govMeasurementsRadiative heating rate govMeasurementsRadiative heating rate ARM Data Discovery Browse Data Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Measurement : Radiative heating rate The heating rate due to the divergence of long and shortwave radiative flux. Categories Radiometric, Atmospheric State Instruments The above measurement is considered scientifically relevant for the following instruments. Refer to the datastream (netcdf) file headers of each instrument for a list of all available measurements, including those recorded for diagnostic or quality assurance purposes. External Instruments MOLTS : Model Output Location Time Series Datastreams MOLTS : Model Output Location Time Series Datastreams MOLTSEDASSNDCLASS1 : Model Output Loc. Time Ser. (MOLTS): EDAS

432

OpenEI - electric rates  

Open Energy Info (EERE)

U.S. Electric Utility U.S. Electric Utility Companies and Rates: Look-up by Zipcode (Feb 2011) http://en.openei.org/datasets/node/899 This dataset, compiled by NREL and Ventyx, provides average residential, commercial and industrial electricity rates by zip code for both investor owned utilities (IOU) and non-investor owned utilities. Note: the file includes average rates for each utility, but not the detailed rate structure data found in the database available via the zip-code look-up feature on the OpenEI Utilities page (http://en.openei.org/wiki/Gateway:Utilities). The data was released by NREL/Ventyx in February 2011.

433

High repetition rate fiber lasers  

E-Print Network [OSTI]

This thesis reports work in high repetition rate femtosecond fiber lasers. Driven by the applications including optical arbitrary waveform generation, high speed optical sampling, frequency metrology, and timing and frequency ...

Chen, Jian, Ph. D. Massachusetts Institute of Technology

2009-01-01T23:59:59.000Z

434

Project Definition Rating Index (PDRI)  

Broader source: Energy.gov [DOE]

The Office of Environmental Management (EM) Project Definition Rating Index (EM-PDRI) is a modification of a commercially developed planning tool that has been tested by an EM team specifically for...

435

Electric Rate Alternatives to Cogeneration  

E-Print Network [OSTI]

"ELECTRIC RATE ALTERNATIVES TO COGENERATION" K. R. SANDBERG, JR. INDUSTRIAL ACCOUNTS MANAGER - TEXAS GULF STATES UTILITIES COMPANY BEAUMONT, TEXAS ABSTRACT This paper discusses electric rate slternatives to cogeneration for the industrisl... PERSPECTIVE Gulf States Utilities was incorporated in 1925 and is primarily in the business of generating. transmitting and distributing electricity to 555.000 customers in southeast Texas and south Louisiana. The service area extends 350 miles westward...

Sandberg, K. R. Jr.

436

Property:OpenEI/UtilityRate/DemandRateStructure/Tier4Rate | Open Energy  

Open Energy Info (EERE)

Rate" Rate" Showing 13 pages using this property. 4 4b524791-bef2-49b1-850b-458730755203 + 5 +, 6 +, 3 +, ... 4b524791-bef2-49b1-850b-458730755203 + 6 + 4b524791-bef2-49b1-850b-458730755203 + 3 + 4b524791-bef2-49b1-850b-458730755203 + 7 + 4b524791-bef2-49b1-850b-458730755203 + 5 + 4b524791-bef2-49b1-850b-458730755203 + 8 + 4b524791-bef2-49b1-850b-458730755203 + 5 + 4b524791-bef2-49b1-850b-458730755203 + 5 + 4b524791-bef2-49b1-850b-458730755203 + 6 + 4b524791-bef2-49b1-850b-458730755203 + 6 + E E40880ac-c27b-4cbf-a011-b0d7d6e10fe9 + 1 + E40880ac-c27b-4cbf-a011-b0d7d6e10fe9 + 1 + E40880ac-c27b-4cbf-a011-b0d7d6e10fe9 + 1 + Retrieved from "http://en.openei.org/w/index.php?title=Property:OpenEI/UtilityRate/DemandRateStructure/Tier4Rate&oldid=53975

437

Advertising Rates from May 2012  

E-Print Network [OSTI]

Advertising Rates from May 2012 Abitrich INSIDE: NEW LIFTOUT Isausedluxurycar worththerisk? Page8 May 5, 2012 #12;1 MODULE WIDE DRIVE TABLOID ADVERTISING SIZES VALID FROM MAY 2012 2 MODULES WIDE 8 3pm Thursday Display Phoned Bookings and AdOnline Noon Thursday Noon Thursday Display Advertising

Peters, Richard

438

1993 Wholesale Power and Transmission Rate Schedules.  

SciTech Connect (OSTI)

Bonneville Power Administration 1993 Wholesale Power Rate Schedules and General Rate Schedule Provisions and 1993 Transmission Rate Schedules and General Transmission Rate Schedule Provisions, contained herein, were approved on an interim basis effective October 1, 1993. These rate schedules and provisions were approved by the Federal Energy Commission, United States Department of Energy, in September, 1993. These rate schedules and provisions supersede the Administration`s Wholesale Power Rate Schedules and General Rate Schedule Provisions and Transmission Rate Schedules and General Transmission Rate Schedule Provisions effective October 1, 1991.

US Bonneville Power Administration

1993-10-01T23:59:59.000Z

439

In-Cylinder Reaction Chemistry and Kinetics During Negative Valve Overlap Fuel Injection Under Low-Oxygen Conditions  

SciTech Connect (OSTI)

Fuel injection into the negative valve overlap (NVO) period is a common method for controlling combustion phasing in homogeneous charge compression ignition (HCCI) as well as other forms of advanced combustion. During this event, at least a portion of the fuel hydrocarbons can be converted to products containing significant levels of H2 and CO, as well as other short chain hydrocarbons by means of thermal cracking, water-gas shift, and partial oxidation reactions, depending on the availability of oxygen and the time-temperature-pressure history. The resulting products alter the autoignition properties of the combined fuel mixture for HCCI. Fuel-rich chemistry in a partial oxidation environment is also relevant to other high efficiency engine concepts (e.g., the dedicated EGR (D-EGR) concept from SWRI). In this study, we used a unique 6-stroke engine cycle to experimentally investigate the chemistry of a range of fuels injected during NVO under low oxygen conditions. Fuels investigated included iso-octane, iso-butanol, ethanol, and methanol. Products from NVO chemistry were highly dependent on fuel type and injection timing, with iso-octane producing less than 1.5% hydrogen and methanol producing more than 8%. We compare the experimental trends with CHEMKIN (single zone, 0-D model) predictions using multiple kinetic mechanisms available in the current literature. Our primary conclusion is that the kinetic mechanisms investigated are unable to accurately predict the magnitude and trends of major species we observed.

Kalaskar, Vickey B [ORNL] [ORNL; Szybist, James P [ORNL] [ORNL; Splitter, Derek A [ORNL] [ORNL; Pihl, Josh A [ORNL] [ORNL; Gao, Zhiming [ORNL] [ORNL; Daw, C Stuart [ORNL] [ORNL

2013-01-01T23:59:59.000Z

440

Federal Energy Management Program: Water Rate Escalations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rate Rate Escalations to someone by E-mail Share Federal Energy Management Program: Water Rate Escalations on Facebook Tweet about Federal Energy Management Program: Water Rate Escalations on Twitter Bookmark Federal Energy Management Program: Water Rate Escalations on Google Bookmark Federal Energy Management Program: Water Rate Escalations on Delicious Rank Federal Energy Management Program: Water Rate Escalations on Digg Find More places to share Federal Energy Management Program: Water Rate Escalations on AddThis.com... Sustainable Buildings & Campuses Operations & Maintenance Greenhouse Gases Water Efficiency Basics Federal Requirements Best Management Practices Analysis and Evaluation Water Rate Escalations Evaluation Service Contracts Case Studies Resources

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

conference rates Summer 2014 Policy Statement  

E-Print Network [OSTI]

conference rates Summer 2014 Policy Statement University Catering and Conferences is an auxiliary and organizations holding education- ally related meetings and events on campus. conference rateS (all rates are per occupies, including lounge. Conference staff available for assistance 24 hours per day. Room-only rates

Oregon, University of

442

conference rates Summer 2013 Policy Statement  

E-Print Network [OSTI]

conference rates Summer 2013 Policy Statement University Catering and Conferences is an auxiliary and organizations holding education- ally related meetings and events on campus. conference rateS (all rates are per occupies, including lounge. Conference staff available for assistance 24 hours per day. Room-only rates

Oregon, University of

443

Interviewer's ratings of personality: can these ratings predict job performance?  

E-Print Network [OSTI]

; Goldberg, 1993a; Guastello, 1993; McCrae k Costa, 1985; McCrae & John, 1992) has been about the validity of the five-factor model as a measure of personality; in other words, does the model truly capture all traits of personality? The five-factor model...; Goldberg, 1981; McCrae & Costa, 1987; McCrae & John, 1992; Peabody & Goldberg, 1989). Tupes and Christal (1958, 1992) were the first to look at peer ratings of personality in a variety of samples. Although these samples varied in length and kind...

Archuleta, Kathryn Diane

2012-06-07T23:59:59.000Z

444

P-D Project Rate Adjustment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Parker-Davis Project Rate Adjustment Data Parker-Davis Project Rate Adjustment Data FY2014 Informal Customer Meeting Notification of Meeting Presentation Preliminary CAS Preliminary Rate Design Preliminary PRS Final Documents Notification of Rates Final CAS Final Rate Design Final PRS FY2013 Informal Customer Meeting Notification of Meeting Presentation Preliminary CAS Preliminary Rate Design Preliminary PRS Supplemental Information Final Documents Notification of Rates Final CAS Final Rate Design Final PRS FY2012 Informal Customer Meeting Notification of Meeting Presentation Preliminary CAS Preliminary Rate Design Preliminary PRS Customer Requested Scenario Final Documents Notification of Rates Final CAS Final Rate Design Final PRS FY2011 Informal Customer Meeting Notification of Meeting Presentation Preliminary CAS Preliminary Rate Design

445

BPA Power Rates (pbl/main)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

recover the costs of generating power and associated expenses. Beginning with the 2010 BPA Rate Case, Power Services and Transmission Services plan to conduct rate cases every...

446

Wholesale Power Rate Schedules | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Services » Rate Schedules » Wholesale Power Rate Schedules Services » Rate Schedules » Wholesale Power Rate Schedules Wholesale Power Rate Schedules October 1, 2012 ALA-1-N Wholesale Power Rate Schedule Area: PowerSouth Energy Cooperative System: Georgia-Alabama-South Carolina October 1, 2012 Duke-1-E Wholesale Power Rate Schedule Area: Duke On-System System: Georgia-Alabama-South Carolina October 1, 2012 Duke-2-E Wholesale Power Rate Schedule Area: Central System: Georgia-Alabama-South Carolina October 1, 2012 Duke-3-E Wholesale Power Rate Schedule Area: None System: Georgia-Alabama-South Carolina October 1, 2012 Duke-4-E Wholesale Power Rate Schedule Area: Duke Self-Schedulers System: Georgia-Alabama-South Carolina October 1, 2012 MISS-1-N Wholesale Power Rate Schedule Area: South Mississippi Electric Power Association

447

Wholesale Power Rate Schedules | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Services » Rate Schedules » Wholesale Power Rate Schedules Services » Rate Schedules » Wholesale Power Rate Schedules Wholesale Power Rate Schedules October 1, 2012 ALA-1-N Wholesale Power Rate Schedule Area: PowerSouth Energy Cooperative System: Georgia-Alabama-South Carolina October 1, 2012 Duke-1-E Wholesale Power Rate Schedule Area: Duke On-System System: Georgia-Alabama-South Carolina October 1, 2012 Duke-2-E Wholesale Power Rate Schedule Area: Central System: Georgia-Alabama-South Carolina October 1, 2012 Duke-3-E Wholesale Power Rate Schedule Area: None System: Georgia-Alabama-South Carolina October 1, 2012 Duke-4-E Wholesale Power Rate Schedule Area: Duke Self-Schedulers System: Georgia-Alabama-South Carolina October 1, 2012 MISS-1-N Wholesale Power Rate Schedule Area: South Mississippi Electric Power Association

448

utility rate | OpenEI Community  

Open Energy Info (EERE)

utility rate utility rate Home Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 11:14 Utility Rates API Version 2 is Live! API developer OpenEI update utility Utility Companies utility rate Utility Rates version 1 version 2 version 3 web service Smart meter After several months of development and testing, the next generation web service for the utility rate database is finally here! I encourage you to check out the V2 Utility Rates API at http://en.openei.org/services/doc/rest/util_rates Rmckeel's picture Submitted by Rmckeel(297) Contributor 22 June, 2012 - 09:30 Increasing ask query limit developer utility rate An NREL user who is trying to use the utility rate service was having an issue. He writes "I noticed that any rates past 10,000 are not accessible via json. For example, this query only returns two entries:

449

System to inject steam and produce oil from the same wellbore through downhole valves switching. Fifth quarterly report  

SciTech Connect (OSTI)

Although EOR by steam injection is used primarily to recover Heavy Oil, the same methods are also applicable to some Light Oil reservoirs. A typical example is that of the Shannon reservoirs in the Teapot Dome field, WY, operated by the DOE, for the US Naval Petroleum Reserve No.3. To show that our technology is also applicable to steam injection in Light Oil reservoirs, a preliminary well design was prepared and submitted to Naval Petroleum Reserve No.3. The Upper and Lower Shannon sandstone reservoirs, of low permeability, in the Teapot Dome field are both highly faulted and fractured. This is a situation where horizontal drainholes, oriented in such a way that they would intersect many of the preexisting fractures and fault zones, would greatly increase the wells productivity, as compared to the current practice of using only vertical wells and hydro-fracturation. Proposed well design includes a single vertical casing, tied-in respectively to a liner-equipped horizontal drainhole drilled into the Lower Shannon and to a liner-equipped vertical hole drilled into the Upper Shannon. The two wells are operated in sequential ``huff and puff,`` using two parallel vertical tubings, respectively dedicated to steam injection and to conveying the produced fluids to the surface, using a single rod pump. Corresponding proposed Teapot Dome well configuration, added to those previously considered for various California Heavy Oil fields confirms the flexibility and adaptability of this technology to a large variety of field conditions, exhibiting wide range of oil and reservoir characteristics. The experiments made at UC Berkeley to verify the operability of sliding sleeve type three-way downhole valves are presented and reviewed. This concludes tasks No.1 to No.4 of this Contract. Calculations of steam tubing heat losses for various well configurations and types of tubing insulations have been made under Task No.5. The results are presented in graphical form and analyzed.

Not Available

1993-12-01T23:59:59.000Z

450

Analysis of main steam isolation valve leakage in design basis accidents using MELCOR 1.8.6 and RADTRAD.  

SciTech Connect (OSTI)

Analyses were performed using MELCOR and RADTRAD to investigate main steam isolation valve (MSIV) leakage behavior under design basis accident (DBA) loss-of-coolant (LOCA) conditions that are presumed to have led to a significant core melt accident. Dose to the control room, site boundary and LPZ are examined using both approaches described in current regulatory guidelines as well as analyses based on best estimate source term and system response. At issue is the current practice of using containment airborne aerosol concentrations as a surrogate for the in-vessel aerosol concentration that exists in the near vicinity of the MSIVs. This study finds current practice using the AST-based containment aerosol concentrations for assessing MSIV leakage is non-conservative and conceptually in error. A methodology is proposed that scales the containment aerosol concentration to the expected vessel concentration in order to preserve the simplified use of the AST in assessing containment performance under assumed DBA conditions. This correction is required during the first two hours of the accident while the gap and early in-vessel source terms are present. It is general practice to assume that at {approx}2hrs, recovery actions to reflood the core will have been successful and that further core damage can be avoided. The analyses performed in this study determine that, after two hours, assuming vessel reflooding has taken place, the containment aerosol concentration can then conservatively be used as the effective source to the leaking MSIV's. Recommendations are provided concerning typical aerosol removal coefficients that can be used in the RADTRAD code to predict source attenuation in the steam lines, and on robust methods of predicting MSIV leakage flows based on measured MSIV leakage performance.

Salay, Michael (United States Nuclear Regulatory Commission, Washington, D.C.); Kalinich, Donald A.; Gauntt, Randall O.; Radel, Tracy E.

2008-10-01T23:59:59.000Z

451

CRSP Transmission Sales Rate History  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Updated: 12/20/2013 Updated: 12/20/2013 CRSP Transmission Sales Rate History Rate Schedule Effective Dates Nonfirm (Mills/kWh) Firm ($/kW-yr.) Firm ($/kW-mo.) None Through 3/83 1.000 $ 6.60 $0.55 SP-FT1 4/83 - 6/86 N.A. $10.27 $0.86 SP-NFT1 4/83 - 6/86 2.000 N.A. SP-FT2 7/86 - 6/89 N.A. $15.94 $1.33 SP-NFT2 7/86 - 7/89 3.100 N.A. SP-FT3 7/89 - 9/92 N.A. $21.72 $1.81 SP-NFT3 8/89 - 3/98 Mutually Agreed N.A. SP-FT4 10/92 - 3/98 N.A. $22.68 $1.89 SP-NFT4 4/98 - 3/03 Mutually Agreed N.A. SP-PTP5 4/98 - 3/99 N.A. $26.70 $2.23 4/99 - 3/00 N.A. $26.19 $2.18 4/00 - 3/01 N.A. $26.14 $2.18 4/01 - 3/02 N.A. $25.63 $2.14 4/02 - 9/02 N.A. $21.33 $1.78 SP-NFT5 10/02 - 9/07 Mutually Agreed N.A. 10/07-9/08 Mutually Agreed N.A. SP-PTP6 10/02 - 9/03 N.A. $24.72 $2.06

452

Combined Retrieval, Microphysical Retrievals and Heating Rates  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Microphysical retrievals and heating rates from the AMIE/Gan deployment using the PNNL Combined Retrieval.

Feng, Zhe

453

7, 29612989, 2007 Predicting arene rate  

E-Print Network [OSTI]

software or computing power. Measured gas-phase rate coefficients for the reaction of aromatic hydrocarbons

Boyer, Edmond

454

conference rates Summer 2012 Policy Statement  

E-Print Network [OSTI]

conference rates Summer 2012 Policy Statement University Catering and Conferences is an auxiliary holding educationally related meetings and events on campus. conference rateS (all rates are per person lounge. Barnhart Hall service includes private bathrooms/showers. Conference staff available

Oregon, University of

455

2014-09-04 Issuance: Energy Conservation Standard for Commercial Prerinse Spray Valves; Notice of Public Meeting and Availability of Framework Document  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of public meeting and availability of framework document regarding energy conservation standards for commercial prerinse spray valves, as issued by the Deputy Assistant Secretary for Energy Efficiency on September 4, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

456

Assessment of a pressurizer spray valve faulty opening transient at Asco Nuclear Power Plant with RELAP5/MOD2. International Agreement Report  

SciTech Connect (OSTI)

The Asociacion Nuclear Asco has prepared a model of Asco NPP using RELAP5/MOD2. This model, which include thermalhydraulics, kinetics and protection and controls, has been qualified in previous calculations of several actual plant transients. One of the transients of the qualification process is a ``Pressurizer spray valve faulty opening`` presented in this report. It consists in a primary coolant depressurization that causes the reactor trip by overtemperature and later on the actuation of the safety injection. The results are in close agreement with plant data.

Reventos, F.; Baptista, J.S.; Navas, A.P.; Moreno, P. [Asociacion Nuclear Asco, Barcelona (Spain)

1993-12-01T23:59:59.000Z

457

Property:OpenEI/UtilityRate/EnergyRateStructure/Tier5Rate | Open Energy  

Open Energy Info (EERE)

Rate" Rate" Showing 25 pages using this property. (previous 25) (next 25) 0 00c88d6d-e3b0-4128-ad3e-a93f686cf6e3 + 0.227 + 00c88d6d-e3b0-4128-ad3e-a93f686cf6e3 + 0.227 + 00c88d6d-e3b0-4128-ad3e-a93f686cf6e3 + 0.227 + 019be14c-4635-4529-af90-799cbf5d7865 + 0.0335 + 019be14c-4635-4529-af90-799cbf5d7865 + 0.0335 + 02b061e1-f065-421e-9ebc-76aef4734486 + 0.079 + 02b061e1-f065-421e-9ebc-76aef4734486 + 0.079 + 02fc76fd-35ff-44c3-bc85-1fb1918f125b + 0.0978 + 02fc76fd-35ff-44c3-bc85-1fb1918f125b + 0.0978 + 0402cc99-ab16-40cc-83e7-2c5910a825a1 + 0.061 + 0402cc99-ab16-40cc-83e7-2c5910a825a1 + 0.061 + 041466a9-81ca-4fce-90e3-e718159347a9 + 0.0587 +, 0.044 + 041466a9-81ca-4fce-90e3-e718159347a9 + 0.044 + 041466a9-81ca-4fce-90e3-e718159347a9 + 0.0587 + 047086c9-976d-4a05-90d5-b67afaf60851 + 0.0583 +

458

High flow rate nozzle system with production of uniform size droplets  

DOE Patents [OSTI]

Method steps for production of substantially uniform size droplets from a flow of liquid include forming the flow of liquid, periodically modulating the momentum of the flow of liquid in the flow direction at controlled frequency, generating a cross flow direction component of momentum and modulation of the cross flow momentum of liquid at substantially the same frequency and phase as the modulation of flow direction momentum, and spraying the so formed modulated flow through a first nozzle outlet to form a desired spray configuration. A second modulated flow through a second nozzle outlet is formed according to the same steps, and the first and second modulated flows impinge upon each other generating a liquid sheet. Nozzle apparatus for modulating each flow includes rotating valving plates interposed in the annular flow of liquid. The plates are formed with radial slots. Rotation of the rotating plates is separably controlled at differential angular velocities for a selected modulating frequency to achieve the target droplet size and production rate for a given flow. The counter rotating plates are spaced to achieve a desired amplitude of modulation in the flow direction, and the angular velocity of the downstream rotating plate is controlled to achieve the desired amplitude of modulation of momentum in the cross flow direction. Amplitude of modulation is set according to liquid viscosity.

Stockel, Ivar H. (Bangor, ME)

1990-01-01T23:59:59.000Z

459

High flow rate nozzle system with production of uniform size droplets  

DOE Patents [OSTI]

Method steps for production of substantially uniform size droplets from a flow of liquid include forming the flow of liquid, periodically modulating the momentum of the flow of liquid in the flow direction at controlled frequency, generating a cross flow direction component of momentum and modulation of the cross flow momentum of liquid at substantially the same frequency and phase as the modulation of flow direction momentum, and spraying the so formed modulated flow through a first nozzle outlet to form a desired spray configuration. A second modulated flow through a second nozzle outlet is formed according to the same steps, and the first and second modulated flows impinge upon each other generating a liquid sheet. Nozzle apparatus for modulating each flow includes rotating valving plates interposed in the annular flow of liquid. The plates are formed with radial slots. Rotation of the rotating plates is separably controlled at differential angular velocities for a selected modulating frequency to achieve the target droplet size and production rate for a given flow. The counter rotating plates are spaced to achieve a desired amplitude of modulation in the flow direction, and the angular velocity of the downstream rotating plate is controlled to achieve the desired amplitude of modulation of momentum in the cross flow direction. Amplitude of modulation is set according to liquid viscosity. 5 figs.

Stockel, I.H.

1990-10-16T23:59:59.000Z

460

Wholesale Power Rate Schedules | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Schedules Schedules Wholesale Power Rate Schedules October 1, 2011 CBR-1-H Wholesale Power Rate Schedule Area: Big Rivers and Henderson, KY System: CU October 1, 2011 CSI-1-H Wholesale Power Rate Schedule Area: Southern Illinois System: CU October 1, 2011 CK-1-H Wholesale Power Rate Schedule Area: KU Area System: CU October 1, 2011 CEK-1-H Wholesale Power Rate Schedule Area: East Kentucky System: CU October 1, 2011 CC-1-I Wholesale Power Rate Schedule Area: CP&L Area, Western Division System: CU September 20, 2011 JW-1-J Wholesale Power Rate Schedule Area: Woodruff Preference Customer System: Jim Woodruff September 20, 2011 JW-2-F Wholesale Power Rate Schedule Area: Florida Power Corporation System: Jim Woodruff November 17, 2010 AP-1-B Wholesale Power Rate Schedule Area: American Electric Power

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

1996 Wholesale Power and Transmission Rate Schedules.  

SciTech Connect (OSTI)

Bonneville Power Administration`s (BPA) 1996 Wholesale Power Rate Schedules, 1996 Ancillary Products and Services Rate Schedule, 1996 Transmission Rate Schedules, and General Rate Schedule Provisions, contained herein, were approved on an interim basis effective October 1, 1996. These rate schedules and provisions were approved by the Federal Energy Regulatory Commission (FERC), United States Department of Energy, in September 1996 (Docket Nos EF96-2011-000 and EF96f-2021-000). These rate schedules and General Rate Schedule Provisions were approved on a final basis by the FERC July 30, 1997, in Dept. of Energy--Bonneville Power Administration, Docket Nos. EF96-2011-000 and EF96-2021-000. Except as noted elsewhere, these 1996 rate schedules and provisions supersede BPA`s Wholesale Power Rate Schedules and General Rate Schedule Provisions, and Transmission Rate Schedules and General Transmission Rate Schedule Provisions, effective October 1, 1995. These rate schedules and general rate schedule provisions include all errata.

United States. Bonneville Power Administration.

1996-10-01T23:59:59.000Z

462

Development of bellows and gate valves with a comb-type rf shield for high-current accelerators: Four-year beam test at KEK B-Factory  

SciTech Connect (OSTI)

Since a comb-type rf shield was proposed in 2003 as a rf shield for future high-intensity accelerators, various types of bellow chambers and gate valves with this rf shield have been installed in the KEK B-Factory rings in series and tested with beams. Through beam tests to check the performance, a structural simplification has been tried in parallel. The temperatures of the bellow corrugations decreased by a factor of 3-6 compared to those with a conventional finger-type rf shield in most cases. The temperatures of the body of the gate valves also decreased by a factor of 2-5. These results demonstrated the availability of the comb-type rf shield. Although a discharge was observed in one simplified model, the latest model has shown no problem up to a stored beam current of 1.8 A (1.3 mA/bunch, 6 mm bunch length). Experiences with the comb-type rf shield in these four-year beam tests are reviewed here.

Suetsugu, Yusuke; Kanazawa, Ken-ichi; Shibata, Kyo; Shirai, Mitsuru; Bondar, Aleksander E.; Kuzminykh, Victor S.; Gorbovsky, Aleksander I.; Sonderegger, Kurt; Morii, Minoru; Kawada, Kakuyu [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801 (Japan); Budker Institute of Nuclear Physics (BINP), Novosibirsk 630090 (Russian Federation); VAT Vakuumventile AG, Haag CH-9469 (Switzerland); VAT SKK Vacuum Ltd., Yokohama, Kanagawa 240-0023 (Japan)

2007-04-15T23:59:59.000Z

463

OpenEI Community - utility rate  

Open Energy Info (EERE)

Rates API Rates API Version 2 is Live! http://en.openei.org/community/blog/utility-rates-api-version-2-live Smart meterAfter several months of development and testing, the next generation web service for the utility rate database is finally here! I encourage you to check out the V2 Utility Rates API at rates">http://en.openei.org/services/doc/rest/util_ratesrates-api-version-2-live" target="_blank">read more

464

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Utility Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: API Type Term Title Author Replies Last Post sort icon Blog entry API The utility rate database version 1 API is now deprecated Rmckeel 6 Sep 2013 - 14:00 Blog entry API Lighting Electricity Rates on OpenEI Sfomail 31 May 2013 - 12:04 Blog entry API Utility Rates API Version 2 is Live! Sfomail 17 May 2013 - 11:14 Groups Menu You must login in order to post into this group. Recent content There is currently no way to s... ranking of utilities by demand charge? FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated more Group members (28) Managers: Dloomis

465

Energy Efficiency Interest Rate Reduction Program  

Broader source: Energy.gov [DOE]

The Alaska Housing Finance Corporation (AHFC) offers interest rate reductions to home buyers purchasing new and existing homes with 5 Star and 5 Star Plus energy ratings. All homes constructed on...

466

Articulatory Rate, Stuttering and Speech Motor Control  

Science Journals Connector (OSTI)

There is a close relation between the rate of speech and stuttering. Struggle behaviors, abnormally repeated and prolonged sounds, and other stuttering behaviors naturally slow the rate of speech. Correlations be...

Barbara J. Amster; C. Woodruff Starkweather

1987-01-01T23:59:59.000Z

467

Stocking Rate: The Key Grazing Management Decision  

E-Print Network [OSTI]

Stocking rate is the most important grazing management decision a rancher makes. This publication covers all the factors involved in determining an appropriate stocking rate, including rainfall and forage production, range condition, and the forage...

Lyons, Robert K.; Machen, Richard V.

2001-07-19T23:59:59.000Z

468

Low Bit Rate Digital Coding of Audio  

Science Journals Connector (OSTI)

Low bit rate digital coding, also known as perceptual coding, makes use of several psychoacoustical masking phenomena to reduce the bit rate required to transmit digital audio. The need for such te...

John M. Eargle

1996-01-01T23:59:59.000Z

469

Commercial Building Energy Asset Rating Workshop  

Broader source: Energy.gov [DOE]

DOE commercial building energy asset rating program information presented to stakeholders at the workshop held in Washington, DC, December 2011

470

Spontaneous Emission Rate Enhancement Using Optical Antennas  

E-Print Network [OSTI]

of  Spontaneous  Emission  in  a  Semiconductor  nanoLED,”  emission  rate  enhancement  using  the  Fluorescent  Emission  by  Lattice   Resonances  in  

Kumar, Nikhil

2013-01-01T23:59:59.000Z

471

POLICY GUIDANCE MEMORANDUM #10 Category Rating  

Broader source: Energy.gov [DOE]

This memorandum is to establish the Department of Energy's (DOE's) policy for the use of Category Rating.

472

Variable accretion rates and fluffy first stars  

Science Journals Connector (OSTI)

......high accretion rate ( Mo yr1, M *= 10.35 Mo) as it passes through the spiral...45 Mo) as it passes through a less...The accretion rate of the orbiting...understand the physics of such an encounter...where the sinks pass within each others...high accretion rates. They show that......

Rowan J. Smith; Takashi Hosokawa; Kazuyuki Omukai; Simon C. O. Glover; Ralf S. Klessen

2012-07-21T23:59:59.000Z

473

High Performance Valve Materials  

Broader source: Energy.gov [DOE]

2009 DOE Hydrogen Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting, May 18-22, 2009 -- Washington D.C.

474

Definition: Emergency Rating | Open Energy Information  

Open Energy Info (EERE)

Emergency Rating Emergency Rating Jump to: navigation, search Dictionary.png Emergency Rating The rating as defined by the equipment owner that specifies the level of electrical loading or output, usually expressed in megawatts (MW) or Mvar or other appropriate units, that a system, facility, or element can support, produce, or withstand for a finite period. The rating assumes acceptable loss of equipment life or other physical or safety limitations for the equipment involved.[1] Related Terms rating References ↑ Glossary of Terms Used in Reliability Standards An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Emergency_Rating&oldid=480317" Categories:

475

Water Rate Escalations | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Rate Escalations Rate Escalations Water Rate Escalations October 8, 2013 - 9:55am Addthis Federal agencies need accurate water cost escalation rates to perform life cycle cost analyses for water efficiency projects to meet Executive Order 13514 and Energy Independence and Security Act of 2007 requirements. To estimate long-term escalation rates of potable water, Pacific Northwest National Laboratory (PNNL) conducted an analysis. Using the trends from this study, Federal facility managers can select escalation rates from studied cities with similar circumstances to their facility locations such as U.S. region, water source, or drought tendencies. Also they can make more informed choices on possible water escalation rates that can be used in economic analysis of water efficiency projects.

476

Utility Rates | OpenEI Community  

Open Energy Info (EERE)

Utility Rates Utility Rates Home Rmckeel's picture Submitted by Rmckeel(297) Contributor 6 September, 2013 - 14:00 The utility rate database version 1 API is now deprecated API Utility Rates There comes a time in every API version's lifecycle when it needs to be deprecated. OpenEI's utility rate database version 1 API has been in use since the inception of the database in 2010. As Illinois State University has taken a commanding lead of the project and its data curation, we have updated the schema and API to version 2 to present a richer spectrum of utility rate data. Rmckeel's picture Submitted by Rmckeel(297) Contributor 11 June, 2013 - 09:33 Tip for working with approvals on OpenEI EZFeed Utility Rates The "ApprovedRevs" extension is the feature on OpenEI that allows

477

Definition: Penetration Rate | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Penetration Rate Jump to: navigation, search Dictionary.png Penetration Rate The Rate of penetration, abbreviated as ROP as used in the drilling industry, is the speed at which a drill bit breaks the rock under it to deepen the borehole. It is normally measured in feet per minute or meters per hour, but sometimes it is expressed in minutes per foot.[1] View on Wikipedia Wikipedia Definition The Rate of penetration, abbreviated as ROP as used in the drilling industry, is the speed at which a drill bit breaks the rock under it to deepen the borehole. Also known as penetration rate or drill rate. It is normally measured in feet per minute or meters per hour, but sometimes it is expressed in minutes per foot.

478

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Utility Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: developer Type Term Title Author Replies Last Post sort icon Blog entry developer Utility Rates API Version 2 is Live! Sfomail 17 May 2013 - 11:14 Discussion developer Utility rate change propagation is now much faster Rmckeel 1 21 Mar 2013 - 09:11 Blog entry developer OpenEI maintenance March 8-9, 2013 Rmckeel 8 Mar 2013 - 14:23 Blog entry developer Semantic Mediawiki Semantic Forms update Rmckeel 22 Oct 2012 - 07:23 Discussion developer Increasing ask query limit Rmckeel 1 28 Jun 2012 - 14:35 Groups Menu You must login in order to post into this group. Recent content FYI, OpenEI now accommodates t... Very useful information. Thank...

479

Rate-Making Policy | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Rate-Making Policy Rate-Making Policy Rate-Making Policy < Back Eligibility Investor-Owned Utility Rural Electric Cooperative Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info Start Date 2005 State Wisconsin Program Type Generating Facility Rate-Making Provider Public Service Commission of Wisconsin WI Act 7 states that, when proposing the purchase or construction of an electric generating facility, a utility may "apply to the [WI Public Service Commission] for an order specifying in advance the rate-making principles" that the Public Service Commission will use for "future rate-making proceedings." The Nuclear Energy Institute highlights that "There is no restriction on

480

Definition: Dynamic Capability Rating | Open Energy Information  

Open Energy Info (EERE)

Capability Rating Capability Rating Jump to: navigation, search Dictionary.png Dynamic Capability Rating Dynamic capability rating can be achieved through real-time determination of an element's (e.g., line, transformer etc.) ability to carry load based on electrical and environmental conditions.[1] Related Terms rating References ↑ SmartGrid.gov 'Description of Functions' An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Dynamic_Capability_Rating&oldid=506158" Categories: Definitions ISGAN Definitions What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load)

Note: This page contains sample records for the topic "relief valve rated" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

THE EXCHANGE RATE-INVESTMENT NEXUS AND EXCHANGE RATE INSTABILITY: ANOTHER REASON FOR `FEAR OF FLOATING'  

E-Print Network [OSTI]

THE EXCHANGE RATE-INVESTMENT NEXUS AND EXCHANGE RATE INSTABILITY: ANOTHER REASON FOR `FEAR repercussion comes through the reaction of firms to changed asset prices and the firms' decisions to invest: F31, F32 *Corresponding author 1 #12;THE EXCHANGE RATE-INVESTMENT NEXUS AND EXCHANGE RATE

Ahmad, Sajjad

482

HEART RATE AS A MONITOR FOR METABOLIC RATE IN CAPTIVE JUVENILE STELLER SEA LIONS (EUMETOPIAS JUBATUS)  

E-Print Network [OSTI]

HEART RATE AS A MONITOR FOR METABOLIC RATE IN CAPTIVE JUVENILE STELLER SEA LIONS (EUMETOPIAS COLUMBIA 0Jan M. Mcl'hee, 2001 #12;ABSTRACT The potential use of heart rate to monitor energy expenditure a relationship exists between heart rate @I) and oxygen consumption ( ~ 0 ~ )in captive sea lions while swimming

483

Utility Rate Discounts | Open Energy Information  

Open Energy Info (EERE)

Discounts Discounts Jump to: navigation, search A few electric utilities offer rate discounts to encourage residential energy efficiency. For homes that meet certain energy efficiency criteria, such as those established by the federal Energy Star program, the owner or tenant is awarded a percentage discount on each monthÂ’s electric bill. [1] Contents 1 Utility Rate Discount Incentives 2 References Utility Rate Discount Incentives CSV (rows 1 - 14) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Cleco Power - Power Miser New Home Program (Louisiana) Utility Rate Discount Louisiana Residential Building Insulation Central Air conditioners Clothes Washers Comprehensive Measures/Whole Building Doors Duct/Air sealing Furnaces Heat pumps

484

Cervical Cancer Rates in Allegheny County Communities.  

E-Print Network [OSTI]

??Aggregated cervical cancer rates for the 21 year period 1985 through 2005 were age-adjusted and standardized for each neighborhood and municipality in Allegheny County, Pennsylvania.… (more)

Assenat, Mary Margaret

2012-01-01T23:59:59.000Z

485

Photovoltaic Degradation Rates -- An Analytical Review  

SciTech Connect (OSTI)

As photovoltaic penetration of the power grid increases, accurate predictions of return on investment require accurate prediction of decreased power output over time. Degradation rates must be known in order to predict power delivery. This article reviews degradation rates of flat-plate terrestrial modules and systems reported in published literature from field testing throughout the last 40 years. Nearly 2000 degradation rates, measured on individual modules or entire systems, have been assembled from the literature, showing a median value of 0.5%/year. The review consists of three parts: a brief historical outline, an analytical summary of degradation rates, and a detailed bibliography partitioned by technology.

Jordan, D. C.; Kurtz, S. R.

2012-06-01T23:59:59.000Z

486

Examiner Characteristics and the Patent Grant Rate  

E-Print Network [OSTI]

Characteristics and the Patent Grant Rate * Mark Lemley †USPTO: whether or not to grant a patent. We ?nd that moreart, are more likely to grant patent applications. These

Lemley, Mark A.

2009-01-01T23:59:59.000Z

487

BPA issues final decision on oversupply rate  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

issues-final-decision-on-oversupply-rate Sign In About | Careers | Contact | Investors | bpa.gov Search News & Us Expand News & Us Projects & Initiatives Expand Projects &...

488

Adaptive Filtering for Heart Rate Signals.  

E-Print Network [OSTI]

?? This work focused on the effects of suppressing the motion artifact of wrist photoplethysmographic heart rate signals. Monitoring of the heart can offer important… (more)

Jaafari, Samira

2014-01-01T23:59:59.000Z

489

Method of controlling fusion reaction rates  

DOE Patents [OSTI]

This invention relates to a method of controlling the reaction rates in a nuclear fusion reactor; and more particularly, to the use of polarized nuclear fuel.

Kulsrud, R.M.; Furth, H.P.; Valeo, E.J.; Goldhaber, M.

1983-05-09T23:59:59.000Z

490

Single Assessment Pass Rate South Carolina  

E-Print Network [OSTI]

Single Assessment Pass Rate South Carolina Academic Year 2004 - 2005 ETS Type of Assessment Test in Cohort 2,218 in Cohort #12;Single Assessment Pass Rate South Carolina Academic Year 2004 - 2005 ETS Type, Part 0063 Middle School Mathematics 0069 Chemistry, Physics and General Science 0070 Social Studies

Kasman, Alex

491

8, 67936824, 2008 dispersion rates in  

E-Print Network [OSTI]

patterns, it is shown that initial buoyancy fluxes at ship stack have minor effect on plume dilution rate modeling and measurement (remote or "in-situ") studies of ship exhaust25 effects must dealACPD 8, 6793­6824, 2008 Ship plume dispersion rates in convective BL F. Chosson et al. Title Page

Paris-Sud XI, Université de

492

Cadmium Biosorption Rate in Protonated Sargassum Biomass  

E-Print Network [OSTI]

Cadmium Biosorption Rate in Protonated Sargassum Biomass J I N B A I Y A N G A N D B O H U M I L V Sargassum fluitans biomass was accompanied by the release of hydrogen protons from the biomass. The uptake the overall biosorption rate of cadmium ions in flat seaweed biomass particles. The overall biosorption

Volesky, Bohumil

493

False Discovery Rates John D. Storey  

E-Print Network [OSTI]

positives. The false discovery rate is designed to quantify this type of trade-off, making it particularly Hypothesis Testing In hypothesis testing, statistical significance is typically based on calculations involving p-values and Type I error rates. A p-value calculated from a single statistical hypothesis test

Storey, John D.

494

Resonances and the thermonuclear reaction rate  

E-Print Network [OSTI]

We present an approximate analytic expression for thermonuclear reaction rate of charged particles when the cross section contains a single narrow or wide resonance described by a Breit-Wigner shape. The resulting expression is uniformly valid as the effective energy and resonance energy coalesce. We use our expressions to calculate the reaction rate for $^{12}$C(p,$\\gamma$)$^{13}$N.

M. S. Hussein; M. Ueda; A. J. Sargeant; M. P. Pato

2003-07-21T23:59:59.000Z

495

Method of controlling fusion reaction rates  

DOE Patents [OSTI]

A method of controlling the reaction rates of the fuel atoms in a fusion reactor comprises the step of polarizing the nuclei of the fuel atoms in a particular direction relative to the plasma confining magnetic field. Fusion reaction rates can be increased or decreased, and the direction of emission of the reaction products can be controlled, depending on the choice of polarization direction.

Kulsrud, Russell M. (Princeton, NJ); Furth, Harold P. (Princeton, NJ); Valeo, Ernest J. (Princeton Junction, NJ); Goldhaber, Maurice (Bayport, NY)

1988-01-01T23:59:59.000Z

496

Definition: Equipment Rating | Open Energy Information  

Open Energy Info (EERE)

Rating Rating Jump to: navigation, search Dictionary.png Equipment Rating The maximum and minimum voltage, current, frequency, real and reactive power flows on individual equipment under steady state, short-circuit and transient conditions, as permitted or assigned by the equipment owner.[1] Also Known As Standard current ratings Related Terms reactive power, smart grid References ↑ Glossary of Terms Used in Reliability Standards An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Equipment_Rating&oldid=502535" Categories: Definitions ISGAN Definitions What links here Related changes Special pages Printable version Permanent link Browse properties

497

OpenEI Community - Utility Rates  

Open Energy Info (EERE)

The utility rate The utility rate database version 1 API is now deprecated http://en.openei.org/community/blog/utility-rate-database-version-1-api-now-deprecated There comes a time in every API version's lifecycle when it needs to be deprecated.OpenEI's utility rate database version 1 API has been in use since the inception of the database in 2010.  As Illinois State University has taken a commanding lead of the project and its data curation, we have updated the schema and API to version 2 to present a richer spectrum of utility rate data.

498

Utility Rate | OpenEI Community  

Open Energy Info (EERE)

Utility Rate Utility Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: challenge Type Term Title Author Replies Last Post sort icon Discussion challenge 2013 Civic Hacking Day Ideas Rmckeel 1 22 May 2013 - 08:23 Groups Menu You must login in order to post into this group. Recent content There is currently no way to s... ranking of utilities by demand charge? FYI, OpenEI now accommodates t... Very useful information. Thank... The utility rate database version 1 API is now deprecated more Group members (28) Managers: Dloomis Rmckeel Sfomail Recent members: MSiira Apin101 Lissacoffey Denizurla Bazouing Gdavis Shehant Anapettirossi Abkatzman BijouLulla Vbugnion Marklane Cbonsig Verdel3c Wisconsin Weatherall Windows Payne

499

Method for Determining Solids Circulation Rate  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Determining Solids Circulation Rate Determining Solids Circulation Rate Contact NETL Technology Transfer Group techtransfer@netl.doe.gov May 2012 Opportunity Research is currently active on the patented technology "Method for Determining Solids Circulation Rate." The technology is available for licensing and/or further collaborative research from the U.S. Department of Energy's National Energy Technology Laboratory. Overview This invention provides a method to measure the rate of solids circulation, particularly in those applications where the solids are recycled back to pro- cesses for further use. The applications include processes such as circulating fluidized bed gasifiers and combustors, as well as chemical looping. In the above applications, determining solids circulation rates is needed to

500

gas rates | OpenEI Community  

Open Energy Info (EERE)

gas rates gas rates Home > Groups > Utility Rate Are there Gas Utility Rates available in OpenEI? Submitted by Nlong on 11 July, 2012 - 11:41 1 answer Points: 1 Hi, OpenEI doesn't have NG utility rates as far as I'm aware. That may be a dataset that is added in the future. You can access natural gas prices by utility and sector by downloading the EIA-176 form from the Energy Information Administration. I've included some links to help you find your way. http://205.254.135.7/survey/form/eia_176/efs176.cfm http://www.eia.gov/oil_gas/natural_gas/applications/eia176query_historical.html -Sfomail Sfomail on 12 July, 2012 - 12:04 Groups Menu You must login in order to post into this group. Recent content There is currently no way to s... ranking of utilities by demand charge?