Waste Heat Powered Ammonia Absorption Refrigeration Unit for LPG Recovery  

SciTech Connect

An emerging DOE-sponsored technology has been deployed. The technology recovers light ends from a catalytic reformer plant using waste heat powered ammonia absorption refrigeration. It is deployed at the 17,000 bpd Bloomfield, New Mexico refinery of Western Refining Company. The technology recovers approximately 50,000 barrels per year of liquefied petroleum gas that was formerly being flared. The elimination of the flare also reduces CO2 emissions by 17,000 tons per year, plus tons per year reductions in NOx, CO, and VOCs. The waste heat is supplied directly to the absorption unit from the Unifiner effluent. The added cooling of that stream relieves a bottleneck formerly present due to restricted availability of cooling water. The 350oF Unifiner effluent is cooled to 260oF. The catalytic reformer vent gas is directly chilled to minus 25oF, and the FCC column overhead reflux is chilled by 25oF glycol. Notwithstanding a substantial cost overrun and schedule slippage, this project can now be considered a success: it is both profitable and highly beneficial to the environment. The capabilities of directly-integrated waste-heat powered ammonia absorption refrigeration and their benefits to the refining industry have been demonstrated.

Donald C, Energy Concepts Co.; Lauber, Eric, Western Refining Co.

2008-06-20T23:59:59.000Z

2

Transport Refrigeration Units: A Technical Assessment  

Science Conference Proceedings (OSTI)

This report evaluates the prospects for operating transport refrigeration systems on electricity while they are stationary at a distribution center or refrigerated warehouses. Because most transport refrigeration units (TRUs) in use today are powered by diesel engines, concentrations of diesel exhaust products including particulate matter occur near these distribution centers. Operating TRUs on electricity would eliminate diesel exhaust emissions concentrations at these facilities, but would increase cos...

2004-09-29T23:59:59.000Z

3

Solar powered refrigeration apparatus  

SciTech Connect

Solar powered refrigeration apparatus is disclosed in which an absorption refrigeration system is operated directly by solar energy. One end of a heat pipe is thermally connected to the boiler of the absorption refrigeration system, and a solar collector is thermally coupled to the other remote end of the heat pipe. The heat pipe is a sealed, evacuated metal tube partially filled with water. The solar collector is a double walled glass vacuum tube with a central axial opening for accommodating the remote end of the heat pipe. Heat energy collected by the solar collector boils the water in the heat pipe to subsequently condense in the area of the boiler thus transferring heat energy along the heat pipe to the boiler. The heat pipe is installed sloping downwardly away from the boiler to permit the return of condensate down the pipe to the solar collector area thus permitting continuous operation.

Theakston, F.H.

1982-12-07T23:59:59.000Z

4

Loveland Water & Power- Refrigerator Recycling Program  

Energy.gov (U.S. Department of Energy (DOE))

Loveland Water & Power is providing an incentive for its customers to recycle their old refrigerators. Interested customers can call the utility to arrange a time to pick up the old...

5

Refrigerant Phase-Change Stirling-Cycle Solar Power Towers  

Science Conference Proceedings (OSTI)

This paper firstly introduces the principles of Refrigerant Phase-Change Stirling-Cycle solar power towers This heat engines use solar reservoire. When the refrigerant in an engine cylinder absorbs heat from high-temperature heat sources, refrigerant ... Keywords: refrigerant phase-change cycle, heat engines, solar power tower, finite-time thermodynamics

Dezhong Huang

2011-01-01T23:59:59.000Z

6

Potential Refrigerants for Power Electronics Cooling  

DOE Green Energy (OSTI)

In the past, automotive refrigerants have conventionally been used solely for the purpose of air conditioning. However, with the development of hybrid-electric vehicles and the incorporation of power electronics (PEs) into the automobile, automotive refrigerants are taking on a new role. Unfortunately, PEs have lifetimes and functionalities that are highly dependent on temperature and as a result thermal control plays an important role in the performance of PEs. Typically, PEs are placed in the engine compartment where the internal combustion engine (ICE) already produces substantial heat. Along with the ICE heat, the additional thermal energy produced by PEs themselves forces designers to use different cooling methods to prevent overheating. Generally, heat sinks and separate cooling loops are used to maintain the temperature. Disturbingly, the thermal control system can consume one third of the total volume and may weigh more than the PEs [1]. Hence, other avenues have been sought to cool PEs, including submerging PEs in automobile refrigerants to take advantage of two-phase cooling. The objective of this report is to explore the different automotive refrigerants presently available that could be used for PE cooling. Evaluation of the refrigerants will be done by comparing environmental effects and some thermo-physical properties important to two-phase cooling, specifically measuring the dielectric strengths of potential candidates. Results of this report will be used to assess the different candidates with good potential for future use in PE cooling.

Starke, M.R.

2005-10-24T23:59:59.000Z

7

Loveland Water and Power - Refrigerator Recycling Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Refrigerator Recycling Program Refrigerator Recycling Program Loveland Water and Power - Refrigerator Recycling Program < Back Eligibility Residential Savings Category Appliances & Electronics Maximum Rebate Limit one rebate per account per year Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Refrigerator and Freezer Recycling: $35 Loveland Water and Power is providing an incentive for its customers to recycle their old refrigerators. Interested customers can call the utility to arrange a time to pick up the old refrigerator. The old refrigerator should be brought outside but remain plugged in so the utility can make it is in working condition. the utility will then take the refrigerator to a recycling facility and issue a $35 bill credit. Other Information

8

Refrigeration system with a compressor-pump unit and a liquid ...  

The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigera ...

9

Verification of a level-3 diesel emissions control strategy for transport refrigeration units.  

E-Print Network (OSTI)

??Transport Refrigeration Units (TRUs) are refrigeration systems used to control the environment of temperature sensitive products while they are being transported from one place to… (more)

Shewalla, Umesh.

2010-01-01T23:59:59.000Z

10

New waste-heat refrigeration unit cuts flaring, reduces pollution  

Science Conference Proceedings (OSTI)

Planetec Utility Services Co. Inc. and Energy Concepts Co. (ECC), with the help of the US Department of Energy (DOE), developed and commissioned a unique waste-heat powered LPG recovery plant in August 1997 at the 30,000 b/d Denver refinery, operated by Ultramar Diamond Shamrock (UDS). This new environmentally friendly technology reduces flare emissions and the loss of salable liquid-petroleum products to the fuel-gas system. The waste heat ammonia absorption refrigeration plant (Whaarp) is the first technology of its kind to use low-temperature waste heat (295 F) to achieve sub-zero refrigeration temperatures ({minus}40 F) with the capability of dual temperature loads in a refinery setting. The ammonia absorption refrigeration is applied to the refinery`s fuel-gas makeup streams to condense over 180 b/d of salable liquid hydrocarbon products. The recovered liquid, about 64,000 bbl/year of LPG and gasoline, increases annual refinery profits by nearly $1 million, while substantially reducing air pollution emissions from the refinery`s flare.

Brant, B.; Brueske, S. [Planetec Utility Services Co., Inc., Evergreen, CO (United States); Erickson, D.; Papar, R. [Energy Concepts Co., Annapolis, MD (United States)

1998-05-18T23:59:59.000Z

11

Performance Evaluation of a 4.5 kW (1.3 Refrigeration Tons) Air-Cooled Lithium Bromide/Water Solar Powered (Hot-Water-Fired) Absorption Unit  

Science Conference Proceedings (OSTI)

During the summer months, air-conditioning (cooling) is the single largest use of electricity in both residential and commercial buildings with the major impact on peak electric demand. Improved air-conditioning technology has by far the greatest potential impact on the electric industry compared to any other technology that uses electricity. Thermally activated absorption air-conditioning (absorption chillers) can provide overall peak load reduction and electric grid relief for summer peak demand. This innovative absorption technology is based on integrated rotating heat exchangers to enhance heat and mass transfer resulting in a potential reduction of size, cost, and weight of the "next generation" absorption units. Rotartica Absorption Chiller (RAC) is a 4.5 kW (1.3 refrigeration tons or RT) air-cooled lithium bromide (LiBr)/water unit powered by hot water generated using the solar energy and/or waste heat. Typically LiBr/water absorption chillers are water-cooled units which use a cooling tower to reject heat. Cooling towers require a large amount of space, increase start-up and maintenance costs. However, RAC is an air-cooled absorption chiller (no cooling tower). The purpose of this evaluation is to verify RAC performance by comparing the Coefficient of Performance (COP or ratio of cooling capacity to energy input) and the cooling capacity results with those of the manufacturer. The performance of the RAC was tested at Oak Ridge National Laboratory (ORNL) in a controlled environment at various hot and chilled water flow rates, air handler flow rates, and ambient temperatures. Temperature probes, mass flow meters, rotational speed measuring device, pressure transducers, and a web camera mounted inside the unit were used to monitor the RAC via a web control-based data acquisition system using Automated Logic Controller (ALC). Results showed a COP and cooling capacity of approximately 0.58 and 3.7 kW respectively at 35 C (95 F) design condition for ambient temperature with 40 C (104 F) cooling water temperature. This is in close agreement with the manufacturer data of 0.60 for COP and 3.9 kW for cooling capacity. This study resulted in a complete performance map of RAC which will be used to evaluate the potential benefits of rotating heat exchangers in making the "next-generation" absorption chillers more compact and cost effective without any significant degradation in the performance. In addition, the feasibility of using rotating heat exchangers in other applications will be evaluated.

Zaltash, Abdolreza [ORNL; Petrov, Andrei Y [ORNL; Linkous, Randall Lee [ORNL; Vineyard, Edward Allan [ORNL

2007-01-01T23:59:59.000Z

12

An Advanced Solar-Powered Rotary Solid Adsorption Refrigerator with High Performance  

E-Print Network (OSTI)

In this paper, according to practical consideration, a new solar powered rotary solid adsorption refrigerator system adopting activated carbon fibre + ethanol as its adsorption pair has been designed with higher performance. Moreover, the principle of the refrigeration cycle, different components of the machine, selection of working pairs and feasible theory analysis of the refrigeration system all have been presented in detail. In addition, it shows that the new refrigerator has many great advantages including a simple structure, fast refrigeration, higher thermodynamic coefficient, friendly to the atmospheric environment, etc. This paper explains that the refrigerating process is constant, which has a promising potential for competing the 'intermittent' cycle reported before. Through improving the refrigerant performance of heat and mass transfer in the adsorbent bed, the refrigeration cycle has been advanced from the aspect of utilization of the thermal energy from low-temperature level resources. In addition, it is shown that the commercial solar powered refrigerator will be existent in the near future.

Zheng, A.; Gu, J.

2006-01-01T23:59:59.000Z

13

Combustion Gas Turbine Power Enhancement by Refrigeration of Inlet Air  

E-Print Network (OSTI)

Combustion gas turbines have gained widespread acceptance for mechanical drive and power generation applications. One key drawback of a combustion turbine is that its specific output and thermal efficiency vary quite significantly with variations in the ambient temperature. On hot days, a machine may experience considerable difficulty in meeting its power demand. One concept that has not received much attention is the cooling down of compressor inlet air. This paper will examine the theoretical and practical implications of concept such as evaporative cooling, intercooling, expansion cooling and compression and absorption refrigeration.

Meher-Homji, C. B.; Mani, G.

1983-01-01T23:59:59.000Z

14

Improved Algorithm and Simulation of the Provision Refrigerating Unit  

Science Conference Proceedings (OSTI)

The dynamic model of reciprocating provision cooling plant is presented, and the algorithm of the model is amended, through the method of quoting an unknown variable, which is enthalpy of the refrigerant at the compressor outlet. Dynamic simulation of ...

HE Zhi-bin; ZHANG Jun-dong; SUN Yu-qing; ZENG Hong; GAN Hui-bing

2007-09-01T23:59:59.000Z

15

Refrigeration system with a compressor-pump unit and a liquid-injection desuperheating line  

DOE Patents (OSTI)

The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigeration system that includes an expansion device, an evaporator, a compressor, a condenser, and a liquid pump between the condenser and the expansion device. The liquid pump improves efficiency of the refrigeration system by increasing the pressure of, thus subcooling, the liquid refrigerant delivered from the condenser to the expansion device. The liquid pump and the compressor are driven by a single driving device and, in this regard, are coupled to a single shaft of a driving device, such as a belt-drive, an engine, or an electric motor. While the driving device may be separately contained, in a preferred embodiment, the liquid pump, the compressor, and the driving device (i.e., an electric motor) are contained within a single sealable housing having pump and driving device cooling paths to subcool liquid refrigerant discharged from the liquid pump and to control the operating temperature of the driving device. In another aspect of the present invention, a liquid injection assembly is included in a refrigeration system to divert liquid refrigerant from the discharge of a liquid pressure amplification pump to a compressor discharge pathway within a compressor housing to desuperheat refrigerant vapor to the saturation point within the compressor housing. The liquid injection assembly includes a liquid injection pipe with a control valve to meter the volume of diverted liquid refrigerant. The liquid injection assembly may also include a feedback controller with a microprocessor responsive to a pressure sensor and a temperature sensor both positioned between the compressor to operate the control valve to maintain the refrigerant at or near saturation.

Gaul, Christopher J. (Thornton, CO)

2001-01-01T23:59:59.000Z

16

United Power - Energy Efficiency Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Rebate Program Energy Efficiency Rebate Program United Power - Energy Efficiency Rebate Program < Back Eligibility Commercial Industrial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Manufacturing Water Heating Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Geothermal Heat Pump: $2,500 + $150/ton TSGT rebate* Air-Source Heat Pumps: $400 + $125-150/ton TSGT rebate Terminal Units: $235 Energy Star Heat Pump Bonus: $100 - $150 Electric Water Heater: $70 - $650, depending on conditions and features Electric Resistive Heat Units: $350/unit Electric Thermal Storage Units: $350/unit + $16/kW TSGT rebate Energy Star Appliances Refrigerator/Freezer: $40 Refrigerator/Freezer Recycling: $75

17

United Power - Business Energy Efficiency Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Business Energy Efficiency Rebate Program Business Energy Efficiency Rebate Program United Power - Business Energy Efficiency Rebate Program < Back Eligibility Commercial Industrial Savings Category Appliances & Electronics Commercial Lighting Lighting Manufacturing Maximum Rebate Lighting System Replacement: $20,000 per project LED Street/Area Lighting: $20,000 per project Refrigerated Case Lighting: $3,000 per project Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Lighting System Replacement: $250 per kW calculated, or 50% of invoiced equipment costs Refrigerated Case Lighting (Reach In): $60 per door Refrigerated Case Lighting (Top Lighting Multi-Deck): $10 per lineal foot LED Street/Area Lighting: Lesser of 25% of head costs or $200 per head Electric Motor: $2/HP + $8/HP from Tri-State

18

Thermoacoustic refrigerators and engines comprising cascading stirling thermodynamic units  

DOE Patents (OSTI)

The present invention includes a thermoacoustic assembly and method for improved efficiency. The assembly has a first stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator and at least one additional heat exchanger. The first stage Stirling thermal unit is serially coupled to a first end of a quarter wavelength long coupling tube. A second stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator, and at least one additional heat exchanger, is serially coupled to a second end of the quarter wavelength long coupling tube.

Backhaus, Scott; Swift, Greg

2013-06-25T23:59:59.000Z

19

A combined power and ejector refrigeration cycle for low temperature heat sources  

Science Conference Proceedings (OSTI)

A combined power and ejector refrigeration cycle for low temperature heat sources is under investigation in this paper. The proposed cycle combines the organic Rankine cycle and the ejector refrigeration cycle. The ejector is driven by the exhausts from the turbine to produce power and refrigeration simultaneously. A simulation was carried out to analyze the cycle performance using R245fa as the working fluid. A thermal efficiency of 34.1%, an effective efficiency of 18.7% and an exergy efficiency of 56.8% can be obtained at a generating temperature of 395 K, a condensing temperature of 298 K and an evaporating temperature of 280 K. Simulation results show that the proposed cycle has a big potential to produce refrigeration and most exergy losses take place in the ejector. (author)

Zheng, B.; Weng, Y.W. [School of Mechanical Engineering, Shanghai Jiaotong University, Shanghai 200240 (China)

2010-05-15T23:59:59.000Z

20

Japanese refrigerators field testing  

SciTech Connect

Residential refrigerators consume the equivalent of 1700 megawatts (MW) of baseload power in the Bonneville Power Administration (BPA) service area. Japanese manufacturers have designed refrigerator units that appear more energy efficient than some currently available American models. This report summarizes preliminary findings from field testing of 12 refrigerators of Japanese manufacture to evaluate annual kilowatt hour (kWh) use during actual operation. The units have also undergone laboratory testing sponsored by BPA at ETL Testing Laboratories, Inc. in Cortland, New York. A final report of the project -- due at the end of 1989 -- will correlate in detail the results of field and laboratory tests in comparison to performance ratings determined by the manufacturer.

Lou, A.T.

1989-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Japanese Refrigerators Field Testing.  

SciTech Connect

Residential refrigerators consume the equivalent of 1700 megawatts (MW) of baseload power in the Bonneville Power Administration (BPA) service area. Japanese manufacturers have designed refrigerator units that appear more energy efficient than some currently available American models. This report summarizes preliminary findings from field testing of 12 refrigerators of Japanese manufacture to evaluate annual kilowatt hour (kWh) use during actual operation. The units have also undergone laboratory testing sponsored by BPA at ETL Testing Laboratories, Inc. in Cortland, New York. A final report of the project -- due at the end of 1989 -- will correlate in detail the results of field and laboratory tests in comparison to performance ratings determined by the manufacturer.

Lou, Albert T.

1989-03-01T23:59:59.000Z

22

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network (OSTI)

.100.110.2 Typical refrigerant: R-134a, R- 600a and other hydrocarbons cture:http://1 Air-cooled condensing unit ncompressioisentropicwithprocess isentropicc realc t COP COP · The diagram gives some efficiency data from commercial vapour- 6 some efficiency data from commercial vapour compression refrigerators (T1 = TH, T2 = TL, data from 1976

Zevenhoven, Ron

23

Refrigerant directly cooled capacitors  

DOE Patents (OSTI)

The invention is a direct contact refrigerant cooling system using a refrigerant floating loop having a refrigerant and refrigeration devices. The cooling system has at least one hermetic container disposed in the refrigerant floating loop. The hermetic container has at least one electronic component selected from the group consisting of capacitors, power electronic switches and gating signal module. The refrigerant is in direct contact with the electronic component.

Hsu, John S. (Oak Ridge, TN); Seiber, Larry E. (Oak Ridge, TN); Marlino, Laura D. (Oak Ridge, TN); Ayers, Curtis W. (Kingston, TN)

2007-09-11T23:59:59.000Z

24

Evaluation of the Super Efficient Refrigerator Program (SERP) in the Bonneville Power Administration service territory  

Science Conference Proceedings (OSTI)

The Super Efficient Refrigerator Program (SERP) is a collaborative utility program intended to transform the market for energy-efficient and environmentally friendly refrigerators. it is one of the first examples of large-scale {open_quotes}market transformation{close_quotes} energy efficiency program. This report documents the evaluation of SERP ({open_quotes}the Program{close_quotes}) in the Bonneville Power Administration`s (Bonneville`s) service territory. Pacific Northwest National Laboratory (PNNL) conducted this evaluation for Bonneville. This study includes the process evaluation, preliminary impact evaluation, and market transformation assessment. It is based on site visits and interviews with refrigerator dealers and manufacturers, industry data, and Bonneville information. Results from this study are compared with those from a parallel study that examines the Program across the 24 participating utilities.

Lee, A.D.; Conger, R.L.

1996-06-01T23:59:59.000Z

25

Modeling of Solar-Powered Single-Effect Absorption Cooling System and Supermarket Refrigeration/HVAC System.  

E-Print Network (OSTI)

?? This thesis consists of two different research problems. In the first one, the aim is to model and simulate a solar-powered, single-effect, absorption refrigeration… (more)

Bahman, Ammar Mohammad Khalil

2011-01-01T23:59:59.000Z

26

Modeling of Solar-Powered Single-Effect Absorption Cooling System and Supermarket Refrigeration/HVAC System.  

E-Print Network (OSTI)

??This thesis consists of two different research problems. In the first one, the aim is to model and simulate a solar-powered, single-effect, absorption refrigeration system… (more)

Bahman, Ammar

2011-01-01T23:59:59.000Z

27

Solutions for Summer Electric Power Shortages: Demand Response andits Applications in Air Conditioning and Refrigerating Systems  

SciTech Connect

Demand response (DR) is an effective tool which resolves inconsistencies between electric power supply and demand. It further provides a reliable and credible resource that ensures stable and economical operation of the power grid. This paper introduces systematic definitions for DR and demand side management, along with operational differences between these two methods. A classification is provided for DR programs, and various DR strategies are provided for application in air conditioning and refrigerating systems. The reliability of DR is demonstrated through discussion of successful overseas examples. Finally, suggestions as to the implementation of demand response in China are provided.

Han, Junqiao; Piette, Mary Ann

2007-11-30T23:59:59.000Z

28

The Stirling alternative. Power systems, refrigerants and heat pumps  

SciTech Connect

This book provides an up-to-date reference on the technology, history, and practical applications of Stirling engines, including recent developments in the field and a convenient survey of the Stirling engine literature. The topics of the book include: fundamentals of Stirling technology, definition and terminology, thermodynamic laws and cycles: some elementary considerations, the Stirling cycle, practical regenerative cycle, theoretical aspects and computer simulation of Stirling machines, mechanical arrangements, control systems, heat exchangers, performance characteristics, working fluids, applications of Stirling machines, advantages of Stirling machines, disadvantages of Stirling machines, Stirling versus internal combustion engines, Stirling versus Rankine engines, applications for Stirling machines, Stirling power systems, the literature and sources of supply, the literature of Stirling engines, and the literature of cryocoolers.

Walker, G.; Reader, G.; Fauvel, O.R.; Bingham, E.R. (Univ. of Calgary, Alberta (Canada))

1993-01-01T23:59:59.000Z

29

Nanoscale devices for solid state refrigeration and power generation,” Twentieth Annual  

E-Print Network (OSTI)

A brief review of various techniques to engineer nanoscale thermal and electrical properties of materials is given. The main emphasis is on various energy conversion mechanisms, particularly, thermo electric refrigeration and power generation. Recent experimental and theoretical results on superlattice and quantum dot thermoelectrics and solidstate and vacuum thermionic thin film devices are reviewed. We also present an overview of the research activities at the multi university Thermionic Energy Conversion Center on the design of solid-state and vacuum devices that could convert heat into electricity with hot side temperatures ranging from 300 to 650C and with high conversion efficiency.

Ali Shakouri

2004-01-01T23:59:59.000Z

30

Energy Efficiency Evaluation of Refrigeration Technologies in Combined Cooling, Heating and Power Systems  

E-Print Network (OSTI)

With development of absorption refrigeration technology, the cooling requirement can be met using various optional refrigeration technologies in a CCHP system, including compression refrigeration, steam double-effect absorption refrigeration, steam single-effect absorption refrigeration, flue gas absorption refrigeration and hot water absorption refrigeration, etc. As a universal criterion, the COP coefficient cannot reflect the difference in availability of driving energy for different chillers. Exergy efficiency of optional chillers in CCHP system was analyzed and compared, which can be regarded as an important reference criterion in comparison of energy efficiency. Furthermore, a new index, relative electricity saving ratio, was put forward for evaluating end energy efficiency of all kinds of chillers in a CCHP system, which indicates actual energy or electricity saving ratio for different absorption chillers with various parameters in contrast to the reference electricity-driven refrigeration scheme.

Zuo, Z.; Hu, W.

2006-01-01T23:59:59.000Z

31

Ammonia usage in vapor compression for refrigeration and air-conditioning in the United States  

SciTech Connect

The impending phaseout of CFCs and HCFCs has led to a worldwide search for refrigerants that can provide equivalent performance while not damaging the environment. Long used as a working fluid in industrial and large-scale refrigeration, ammonia provides high efficiency, low initial cost, and no detrimental impact to the environment. However, its toxicity and flammability, along with technical considerations and increased operating costs, deter its use in many refrigeration and cooling applications. Utilization of ammonia in applications where its safety considerations and technical concerns can be addressed provides the best growth opportunity for adoption as a replacement refrigerant. Applications such as district or large-scale cooling, thermal storage, packaged systems, and combined systems hold promise for increased usage of ammonia. Ongoing research and development are providing solutions to technical considerations, and innovations in safety and containment of ammonia are addressing those particular concerns, but code restrictions and regulations present the greatest barrier to wider adoption of ammonia as an alternate refrigerant in the US To encourage wider use, future efforts will need to continue on improved safety and more efficient design, along with an increased emphasis on educating and informing industry and the public about the advantages ammonia and the factors restricting its use.

Fairchild, P.D.; Baxter, V.D.

1995-12-31T23:59:59.000Z

32

Factors driving wind power development in the United States  

E-Print Network (OSTI)

s Largest Purchase of Wind Power,” September 17, 2001.FACTORS DRIVING WIND POWER DEVELOPMENT IN THE UNITED STATESthe United States third in wind power capacity globally,

Bird, Lori A.; Parsons, Brian; Gagliano, Troy; Brown, Matthew H.; Wiser, Ryan H.; Bolinger, Mark

2003-01-01T23:59:59.000Z

33

Solar-powered cooling system  

SciTech Connect

A solar-powered adsorption-desorption refrigeration and air conditioning system uses nanostructural materials made of high specific surface area adsorption aerogel as the adsorptive media. Refrigerant molecules are adsorbed on the high surface area of the nanostructural material. A circulation system circulates refrigerant from the nanostructural material to a cooling unit.

Farmer, Joseph C

2013-12-24T23:59:59.000Z

34

Lianyungang Zhongneng United Wind Power Co Ltd | Open Energy...  

Open Energy Info (EERE)

Page Edit with form History Facebook icon Twitter icon Lianyungang Zhongneng United Wind Power Co Ltd Jump to: navigation, search Name Lianyungang Zhongneng United Wind Power...

35

Emissions of Transport Refrigeration Units with CARB Diesel, Gas-to-Liquid Diesel, and Emissions Control Devices  

Science Conference Proceedings (OSTI)

A novel in situ method was used to measure emissions and fuel consumption of transport refrigeration units (TRUs). The test matrix included two fuels, two exhaust configurations, and two TRU engine operating speeds. Test fuels were California ultra low sulfur diesel and gas-to-liquid (GTL) diesel. Exhaust configurations were a stock muffler and a Thermo King pDPF diesel particulate filter. The TRU engine operating speeds were high and low, controlled by the TRU user interface. Results indicate that GTL diesel fuel reduces all regulated emissions at high and low engine speeds. Application of a Thermo King pDPF reduced regulated emissions, sometimes almost entirely. The application of both GTL diesel and a Thermo King pDPF reduced regulated emissions at high engine speed, but showed an increase in oxides of nitrogen at low engine speed.

Barnitt, R. A.; Chernich, D.; Burnitzki, M.; Oshinuga, A.; Miyasato, M.; Lucht, E.; van der Merwe, D.; Schaberg, P.

2010-05-01T23:59:59.000Z

36

Charcoal-methanol adsorption refrigerator powered by a compound parabolic concentrating solar collector  

SciTech Connect

A compound parabolic concentrating solar collector (CPC) of concentration ratio 3.9 and aperture area 2.0 m[sup 2] was used to power an intermittent solid adsorption refrigerator and ice maker using activated charcoal (carbon) as the adsorbing medium and methanol as the working fluid. The copper tube receiver of the CPC was packed with 2.5 kg of imported adsorbent 207E3, which was only utilized when the performance of activated charcoal (ACJ1, produced from local coconut shells) was found to be inferior to the imported adsorbent. Up to 1 kg of ice at an evaporator temperature of [minus]6[degrees]C was produced, with the net solar coefficient of performance (COP) being of the order of 0.02. Maximum receiver/adsorbent temperature recorded was 154[degrees]C on a day when the insolation was 26.8 MJ/m[sup [minus]2]. Temperatures in excess of 150[degrees]C are undesirable since they favour the conversion of methanol to dimethyl ether, a noncondensable gas which inhibits both condensation and adsorption. The major advantage of this system is its ability to produce ice even on overcast days (insolation [approximately] 10 MJ/m[sup [minus]2]).

Headley, O.StC.; Kothdiwala, A.F.; McDoom, I.A. (Univ. of the West Indies, St. Augustine (Trinidad and Tobago))

1994-08-01T23:59:59.000Z

37

Solutions for Summer Electric Power Shortages: Demand Response and its Applications in Air Conditioning and Refrigerating Systems  

E-Print Network (OSTI)

LBNL-63806 Refrigeration, Air Conditioning, & Electric Powerand its Applications in Air Conditioning and Refrigeratingand its applications in Air Conditioning and refrigerating

Han, Junqiao; Piette, Mary Ann

2008-01-01T23:59:59.000Z

38

Solid Oxide Fuel Cell Auxiliary Power Unit  

SciTech Connect

Solid Oxide Fuel Cell (SOFC) is an attractive, efficient, clean source of power for transportation, military, and stationary applications. Delphi has pioneered its application as an auxiliary Power Unit (APU) for transportation. Delphi is also interested in marketing this technology for stationary applications. Its key advantages are high efficiency and compatibility with gasoline, natural gas and diesel fuel. It's consistent with mechanizations that support the trend to low emissions. Delphi is committed to working with customers and partners to bring this novel technology to market.

J. Weber

2001-12-12T23:59:59.000Z

39

Ground Loops for Heat Pumps and Refrigeration  

E-Print Network (OSTI)

Ground loops are used for water source heat pumps. Refrigeration can be put on a ground loop. Water-cooled condensing units are more efficient than air-cooled, and they can be put indoors. Indoor location makes piping for desuperheater hot water easy. Since refrigeration equipment runs more than heat pumps, energy savings can be large for ground-coupled refrigeration. The paper presents a design procedure for ground loops for heat pumps, hot water, ice machines, and water-cooled refrigeration. It gives an overview of the commercial ground-coupled systems in Louisiana that have both refrigeration and heat pumps. Systems vary from small offices to a three-story office building with 187 tons. A chain of hamburger outlets uses total ground-coupling in all of its stores. A grocery store has ground-coupling for heat pumps and refrigeration. Desuperheaters provide 80 percent of the hot water for a coin laundry in the same building. A comparison of energy costs in a bank with a ground-coupled heat pump system to a similar bank with air-conditioning and gas for heat revealed a 31 percent reduction in utility costs for the ground-coupled building. Two buildings of the Mississippi Power and Light Co. have ground-coupled heat pumps in one, and high efficiency air source heat pumps in the other. Energy savings in nine months was 60,000 kWh (25 percent), and electric peak demand was reduced 42 kW (35 percent).

Braud, H. J.

1986-01-01T23:59:59.000Z

40

NREL's Energy-Saving Technology for Air Conditioning Cuts Peak Power Loads Without Using Harmful Refrigerants (Fact Sheet)  

SciTech Connect

This fact sheet describes how the DEVAP air conditioner was invented, explains how the technology works, and why it won an R&D 100 Award. Desiccant-enhanced evaporative (DEVAP) air-conditioning will provide superior comfort for commercial buildings in any climate at a small fraction of the electricity costs of conventional air-conditioning equipment, releasing far less carbon dioxide and cutting costly peak electrical demand by an estimated 80%. Air conditioning currently consumes about 15% of the electricity generated in the United States and is a major contributor to peak electrical demand on hot summer days, which can lead to escalating power costs, brownouts, and rolling blackouts. DEVAP employs an innovative combination of air-cooling technologies to reduce energy use by up to 81%. DEVAP also shifts most of the energy needs to thermal energy sources, reducing annual electricity use by up to 90%. In doing so, DEVAP is estimated to cut peak electrical demand by nearly 80% in all climates. Widespread use of this cooling cycle would dramatically cut peak electrical loads throughout the country, saving billions of dollars in investments and operating costs for our nation's electrical utilities. Water is already used as a refrigerant in evaporative coolers, a common and widely used energy-saving technology for arid regions. The technology cools incoming hot, dry air by evaporating water into it. The energy absorbed by the water as it evaporates, known as the latent heat of vaporization, cools the air while humidifying it. However, evaporative coolers only function when the air is dry, and they deliver humid air that can lower the comfort level for building occupants. And even many dry climates like Phoenix, Arizona, have a humid season when evaporative cooling won't work well. DEVAP extends the applicability of evaporative cooling by first using a liquid desiccant-a water-absorbing material-to dry the air. The dry air is then passed to an indirect evaporative cooling stage, in which the incoming air is in thermal contact with a moistened surface that evaporates the water into a separate air stream. As the evaporation cools the moistened surface, it draws heat from the incoming air without adding humidity to it. A number of cooling cycles have been developed that employ indirect evaporative cooling, but DEVAP achieves a superior efficiency relative to its technological siblings.

Not Available

2012-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network (OSTI)

of the tower An (earlier) alternative is to use a spray pond to cool water; disadvantages are a large areaRefrigerationRefrigerationRefrigeration coursecourse # 424503.0# 424503.0 v.v. 20122012 7. Air conditioning, cooling towersg, g Ron Zevenhoven Ã?Ã?bo, is the hi htemperature at which condensation begins when air is cooled at constant pressurecooled

Zevenhoven, Ron

42

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network (OSTI)

refrigeration processes (4 5) Vapor-compression refrigeration processes (4-5) Absorption refrigeration; Gas processing (O2, H2, CO2, LPG, LNG...) (3) Air conditioning, cooling towers, rg/pages/zon Air conditioning, cooling towers, food cooling and freezing (4) Heat pumps, heat pipes, special ww.sgisland.o p p

Zevenhoven, Ron

43

United Power, Inc | Open Energy Information  

Open Energy Info (EERE)

Power, Inc Power, Inc Place Colorado Utility Id 19499 Utility Location Yes Ownership C NERC Location WECC NERC WECC Yes Activity Retail Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates Residential: $0.1150/kWh Commercial: $0.0990/kWh Industrial: $0.0830/kWh The following table contains monthly sales and revenue data for United Power, Inc (Colorado). Month RES REV (THOUSAND $) RES SALES (MWH) RES CONS COM REV (THOUSAND $) COM SALES (MWH) COM CONS IND_REV (THOUSAND $) IND SALES (MWH) IND CONS OTH REV (THOUSAND $) OTH SALES (MWH) OTH CONS TOT REV (THOUSAND $) TOT SALES (MWH) TOT CONS

44

Wind Power Price Trends in the United States  

E-Print Network (OSTI)

Review] Wind Power Price Trends in the United States Markof these drivers – i.e. , trends in U.S. wind power prices –Capacity Wind Power Price Trends in the U.S. Berkeley Lab

Bolinger, Mark

2010-01-01T23:59:59.000Z

45

Refrigeration requirements for fusion reactors based upon the theta-pinch concept  

DOE Green Energy (OSTI)

Two refrigeration systems applicable to the theta-pinch fusion concept are described. The first is a 1100 W, 4.5 K refrigerator which will be used for testing superconducting NbTi Magnetic Energy Transfer and Storage (METS) coil systems. This unit is currently being installed and is to be operational by April 1977. The second unit is applicable to the Syllac Fusion Test Reactor (SFTR) and has been conceptually designed. This liquefier-refrigerator is about 22 times larger than those in existence at present and will require 12-MW input electrical power. It will provide 3045 kg/h of liquid helium at 4.5 K.

Williamson, K.D. Jr.; King, C.R.

1976-01-01T23:59:59.000Z

46

NICE3: Industrial Refrigeration System  

SciTech Connect

Energy Concepts has developed an absorption-augmented system as a cost-effective means of achieving more cooling capacity with a substantial reduction in energy consumption and greenhouse gas emissions for industrial refrigeration. It cuts fuel consumption by 30% by combining an internal combustion engine with a mechanical compression refrigeration system and an absorption refrigeration system. The absorption system is powered by engine waste heat. Conventional industrial refrigeration uses mechanical vapor compression, powered by electric motors, which results in higher energy costs. By the year 2010, the new system could cut fuel consumption by 19 trillion Btu and greenhouse emissions by more than 1 million tons per year.

Simon, P.

1999-09-29T23:59:59.000Z

47

Frontiers in thermoacoustic refrigeration and mixture separation  

E-Print Network (OSTI)

pulse-tube refrigerator shown in Figure 1 dissipates acoustic power by design because power must flowFrontiers in thermoacoustic refrigeration and mixture separation S. Backhaus1 , D. Geller2 , B oscillating thermodynamics in a gas in a sealed system. Since then, many related engines and refrigerators

48

Vaccine refrigerator testing. Final report  

SciTech Connect

For the Central American Health Clinic Project initiated in 1986, Sandia National Laboratories and the Florida Solar Energy Center recognized the need for a test and evaluation program for vaccine refrigeration systems. At the Florida Solar Energy Center, side-by-side testing of three photovoltaic powered vaccine refrigerators began in 1987. The testing was expanded in 1988 to include a kerosene absorption refrigerator. This report presents observations, conclusions, and recommendations derived from testing the four vaccine refrigeration systems. Information is presented pertaining to the refrigerators, photovoltaic arrays, battery subsystems, charge controllers, and user requirements. This report should be of interest to designers, manufacturers, installers, and users of photovoltaic-powered vaccine refrigeration systems and components.

Ventre, G.G. [Univ. of Central Florida, Orlando, FL (United States); Kilfoyle, D.; Marion, B. [Florida Solar Energy Center, Cape Canaveral, FL (United States)

1990-06-01T23:59:59.000Z

49

Performance of ECM controlled VAV fan powered terminal units  

E-Print Network (OSTI)

Empirical performance models of fan airflow, primary airflow and power consumption were developed for series and parallel variable air volume fan powered terminal units. An experimental setup and test procedure were created to test the terminal units at typical design pressures and airflows. Each terminal unit observed in this study used an 8 in (20.3 cm) primary air inlet. Two fan motor control methods were considered. The primary control of interest was the electronically commutated motor (ECM) controller. Data collected were compared with previous research regarding silicon rectified control (SCR) units. Generalized models were developed for both series and parallel terminal units. Coefficients for performance models were then compared with comparable SCR controlled units. Non-linear statistical modeling was performed using SPSS software (2008). In addition to airflow and power consumption modeling, power quality was also quantified. Relationships between real power (watts) and apparent power (VA) were presented as well as harmonic frequencies and total harmonic distortion. Power quality was recorded for each ECM controlled terminal unit tested. Additional tests were also made to SCR controlled terminal units used in previous research (Furr 2006). The airflow and power consumption performance models had an R2 equal to 0.990 or greater for every terminal unit tested. An air leakage model was employed to account for leakage in the parallel designed VAV terminal units when the internal fan was turned off. For the leakage model, both ECM and SCR controlled units achieved an R2 greater than or equal to 0.918.

Cramlet, Andrew Charles

2008-08-01T23:59:59.000Z

50

Economic analysis of wind-powered refrigeration cooling/water-heating systems in food processing. Final report  

DOE Green Energy (OSTI)

Potential applications of wind energy include not only large central turbines that can be utilized by utilities, but also dispersed systems for farms and other applications. The US Departments of Energy (DOE) and Agriculture (USDA) currently are establishing the feasibility of wind energy use in applications where the energy can be used as available, or stored in a simple form. These applications include production of hot water for rural sanitation, heating and cooling of rural structures and products, drying agricultural products, and irrigation. This study, funded by USDA, analyzed the economic feasibility of wind power in refrigeration cooling and water heating systems in food processing plants. Types of plants included were meat and poultry, dairy, fruit and vegetable, and aquaculture.

Garling, W.S.; Harper, M.R.; Merchant-Geuder, L.; Welch, M.

1980-03-01T23:59:59.000Z

51

Guodian United Power Technology Co Ltd formerly Guodian Union Power | Open  

Open Energy Info (EERE)

United Power Technology Co Ltd formerly Guodian Union Power United Power Technology Co Ltd formerly Guodian Union Power Jump to: navigation, search Name Guodian United Power Technology Co Ltd (formerly Guodian Union Power) Place Beijing, Beijing Municipality, China Zip 100044 Sector Wind energy Product China-based wind turbine maker and daughter company of state-owned power generator China Guodian. References Guodian United Power Technology Co Ltd (formerly Guodian Union Power)[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Guodian United Power Technology Co Ltd (formerly Guodian Union Power) is a company located in Beijing, Beijing Municipality, China . References ↑ "Guodian United Power Technology Co Ltd (formerly Guodian

52

Wind Power Development in the United States: The Perfect (Wind...  

NLE Websites -- All DOE Office Websites (Extended Search)

Wind Power Development in the United States: The Perfect (Wind) Storm? Speaker(s): Mark Bolinger Date: February 25, 2008 - 12:00pm Location: 90-3122 Wind power development is...

53

Solar powered unitized regenerative fuel cell system  

Science Conference Proceedings (OSTI)

Solar hydrogen system is a unique power system that can meet the power requirement for the energy future demand, in such a system the hydrogen used to be the energy carrier which can produced through electrolysis by using the power from the PV during ... Keywords: electrolyzer, fuel cell, hydrogen, photovoltaic, regenerative, solar hydrogen system

Salwan S. Dihrab; , Kamaruzzaman Sopian; Nowshad Amin; M. M. Alghoul; Azami Zaharim

2008-02-01T23:59:59.000Z

54

Thermal Unit Commitment Including Optimal AC Power Flow Constraints  

E-Print Network (OSTI)

Thermal Unit Commitment Including Optimal AC Power Flow Constraints Carlos Murillo{Sanchez Robert J algorithm for unit commitment that employs a Lagrange relaxation technique with a new augmentation. This framework allows the possibility of committing units that are required for the VArs that they can produce

55

United Power - Renewable Energy Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

United Power - Renewable Energy Rebate Program United Power - Renewable Energy Rebate Program United Power - Renewable Energy Rebate Program < Back Eligibility Commercial Residential Savings Category Solar Buying & Making Electricity Heating & Cooling Water Heating Wind Maximum Rebate PV: 2,250 Wind: 1,500 Solar Water Heating: 1,000 Program Info State Colorado Program Type Utility Rebate Program Rebate Amount PV: 0.75/W Wind: 0.50/W Solar Water Heating: 25/MBtu Provider United Power United Power is providing rebates to their customers for the purchase of photovoltaic (PV), wind, and solar water heating systems. These incentives are separate from the rebates provided by the Colorado Governor's Energy Office and require separate applications. PV and wind systems must be grid-connected. Systems up to 25 kW in capacity may be installed, but

56

Control system for heat exchangers fans in a refrigeration system  

Science Conference Proceedings (OSTI)

The paper presents a method for controlling evaporator and condenser fans in a refrigeration system. The refrigeration system includes a refrigerant circuit defined by a compressor, a condenser, a throttling device, and an evaporator. The system includes ... Keywords: controlling, fan, refrigeration system, variable frequency drive unit

Cristian Iosifescu; Valeriu Damian; C?lin Ciufudean

2010-05-01T23:59:59.000Z

57

Variable gas spring for matching power output from FPSE to load of refrigerant compressor  

DOE Patents (OSTI)

The power output of a free piston Stirling engine is matched to a gas compressor which it drives and its stroke amplitude is made relatively constant as a function of power by connecting a gas spring to the drive linkage from the engine to the compressor. The gas spring is connected to the compressor through a passageway in which a valve is interposed. The valve is linked to the drive linkage so it is opened when the stroke amplitude exceeds a selected limit. This allows compressed gas to enter the spring, increase its spring constant, thus opposing stroke increase and reducing the phase lead of the displacer ahead of the piston to reduce power output and match it to a reduced load power demand. 6 figs.

Chen, G.; Beale, W.T.

1990-04-03T23:59:59.000Z

58

Variable gas spring for matching power output from FPSE to load of refrigerant compressor  

DOE Patents (OSTI)

The power output of a free piston Stirling engine is matched to a gas compressor which it drives and its stroke amplitude is made relatively constant as a function of power by connecting a gas spring to the drive linkage from the engine to the compressor. The gas spring is connected to the compressor through a passageway in which a valve is interposed. The valve is linked to the drive linkage so it is opened when the stroke amplitude exceeds a selected limit. This allows compressed gas to enter the spring, increase its spring constant, thus opposing stroke increase and reducing the phase lead of the displacer ahead of the piston to reduce power output and match it to a reduced load power demand.

Chen, Gong (Athens, OH); Beale, William T. (Athens, OH)

1990-01-01T23:59:59.000Z

59

BioPower Application (United States) | Open Energy Information  

Open Energy Info (EERE)

BioPower Application (United States) BioPower Application (United States) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: BioPower Application (United States) Focus Area: Ethanol Topics: Potentials & Scenarios Website: rpm.nrel.gov/biopower/biopower/launch Equivalent URI: cleanenergysolutions.org/content/biopower-application-united-states,ht Language: English Policies: Deployment Programs DeploymentPrograms: Demonstration & Implementation BioPower is an interactive map for comparing biomass feedstocks and biopower by location. This tool helps users select from and apply biomass data layers to a map as well as query and download biopower and feedstock data. The analysis function offers common conversion factors that allow users to determine the potential biopower production for a selected

60

Direct condensation refrigerant recovery and restoration system  

Science Conference Proceedings (OSTI)

This patent describes a refrigerant recovery and purification system for removing gaseous refrigerant from a disabled refrigeration unit, cleaning the refrigerant of contaminants, and converting the gaseous refrigerant to a liquid state for storage. It comprises a low pressure inlet section; a high pressure storage section; the low pressure inlet section comprising: an oil and refrigerant gas separator, including a separated oil removal means, first conduit means for connecting an inlet of the separator to the disabled refrigerant unit, a slack-sided accumulator, second conduit means connecting the separator to the slack-sided accumulator, a reclaim condenser, third conduit means connecting the separator and the reclaim condenser in series, an evaporator coil in the reclaim condenser connectable to a conventional operating refrigeration system for receiving a liquid refrigerant under pressure for expansion therein, the evaporator coil forming a condensing surface for condensing the refrigerant gas at near atmospheric pressure in the condenser, a liquid receiver, a reclaimed refrigerant storage tank, fourth conduit means further connecting the liquid receiver in series with the reclaim condenser, downstream thereof, means between the reclaim condenser and the liquid receiver.

Grant, D.C.H.

1992-03-10T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Refrigerator recycling and CFCs  

SciTech Connect

Utility-sponsored refrigerator and freezer pick-up programs have removed almost 900,000 inefficient appliances from the North American electric grid to date. While the CFC-12 refrigerant from the discarded appliances is typically removed and recycled, in all but a few programs the CFC-11 in the foam insulation is not. About a quarter-billion pounds of CFC-11 are banked in refrigerator foam in the United States. Release of this ``bank`` of CFC, combined with that from foam insulation used in buildings, will be the largest source of future emissions if preventive measures are not taken. Methods exist to recover the CFC for reuse or to destroy it by incineration. The task of recycling or destroying the CFCs and other materials from millions of refrigerators is a daunting challenge, but one in which utilities can play a leadership role. E Source believes that utilities can profitably serve as the catalyst for public-private partnerships that deliver comprehensive refrigerator recycling. Rather than treating such efforts solely as a DSM resource acquisition, utilities could position these programs as a multifaceted service delivery that offers convenient appliance removal for homeowners, a solid waste minimization service for landfills, a source of recycled materials for industry, and a CFC recovery and/or disposal service in support of the HVAC industry and society`s atmospheric protection goals and laws. Financial mechanisms could be developed through these public-private enterprises to ensure that utilities are compensated for the extra cost of fully recycling refrigerators, including the foam CFC.

Shepard, M.; Hawthorne, W.; Wilson, A.

1994-12-31T23:59:59.000Z

62

BETWEEN UNITED STATES DEPARTMENT OF ENERGY WESTERN AREA POWER ADMINISTRATION  

NLE Websites -- All DOE Office Websites (Extended Search)

12-SLC-0663 12-SLC-0663 CONTRACT NO. 12-SLC-0663 BETWEEN UNITED STATES DEPARTMENT OF ENERGY WESTERN AREA POWER ADMINISTRATION COLORADO RIVER STORAGE PROJECT MANAGEMENT CENTER AND SHELL ENERGY NORTH AMERICA FOR PURCHASE OF POWER Contract No. 12-SLC-0663 1 TABLE OF CONTENTS Section Title Page No. 1 Preamble ............................................................................................................... 2 2 Explanatory Recitals ............................................................................................ 2 3 Agreement ............................................................................................................. 3 4 Term of Contract .................................................................................................. 3

63

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network (OSTI)

) and gives it off at higher ail.asp?article temperature (and pressure) and gives it off at higher temperature or no pressure changes Coolant for an engine: e:http://www 8.11.2012Ã?bo Akademi Univ - Thermal and Flow Engineering - Piispankatu 8, 20500 Turku 32/64 pressure changes. Coolant for an engine: not a refrigerant

Zevenhoven, Ron

64

New Report Finds the United States Leading in Wind Power Growth  

New Report Finds the United States Leading in Wind Power Growth For the third year in a row, the United States was the fastest growing wind power ...

65

Impact of Wind PowerImpact of Wind Power Forecasting on Unit  

E-Print Network (OSTI)

Impact of Wind PowerImpact of Wind Power Forecasting on Unit Commitment and Dispatchp Jianhui Wang and University of Porto, Portugal 8th Int. Wind Integration Workshop, Bremen, Germany, Oct. 14 2009 #12;Outline of the information in wind power forecasts in system and market operationsin system and market operations Stochastic

Hudson, Randy

66

Proposed Methodology for LEED Baseline Refrigeration Modeling (Presentation)  

SciTech Connect

This PowerPoint presentation summarizes a proposed methodology for LEED baseline refrigeration modeling. The presentation discusses why refrigeration modeling is important, the inputs of energy models, resources, reference building model cases, baseline model highlights, example savings calculations and results.

Deru, M.

2011-02-01T23:59:59.000Z

67

Thermal Analysis of Refrigeration Systems Used for Vaccine ...  

Science Conference Proceedings (OSTI)

... may result from planned HVAC outages at night or ... recording data after the refrigerator was powered. ... the length of the power outage and the ...

2012-08-02T23:59:59.000Z

68

Federal Energy Management Program: New and Underutilized Refrigeration...  

NLE Websites -- All DOE Office Websites (Extended Search)

Power Management, and Vending Machine Technologies to someone by E-mail Share Federal Energy Management Program: New and Underutilized Refrigeration, Computer Power Management,...

69

A modified unit decommitment algorithm in combined heat and power production planning  

Science Conference Proceedings (OSTI)

This paper addresses the unit commitment in multi-period combined heat and power (CHP) production planning, considering the possibility to trade power on the spot market. We present a modified unit decommitment algorithm (MUD) that starts with a good ... Keywords: combined heat and power production, deregulated power market, energy optimization, modelling, modified unit decommitment, unit commitment

Aiying Rong; Risto Lahdelma

2007-01-01T23:59:59.000Z

70

Radionuclides in United States commercial nuclear power reactors  

SciTech Connect

In the next ten to twenty years, many of the commercial nuclear power reactors in the United States will be reaching their projected lifetime of forty years. As these power plants are decommissioned, it seems prudent to consider the recycling of structural materials such as stainless steel. Some of these materials and components have become radioactive through either nuclear activation of the elements within the components or surface contamination with radioactivity form the operational activities. In order to understand the problems associated with recycling stainless steel from decommissioned nuclear power reactors, it is necessary to have information on the radionuclides expected on or in the contaminated materials. A study has been conducted of radionuclide contamination information that is available for commercial nuclear power reactors in the United States. There are two types of nuclear power reactors in commercial use in the United States, pressurized water reactors (PWRs) and boiling water reactors (BWRs). Before presenting radionuclide activities information, a brief discussion is given on the major components and operational differences for the PWRs and BWRs. Radionuclide contamination information is presented from 11 PWRs and over 8 BWRs. These data include both the radionuclides within the circulating reactor coolant water as well as radionuclide contamination on and within component parts.

Bechtold, T.E. [ed.] [Westinghouse Idaho Nuclear Co., Inc., Idaho Falls, ID (United States); Dyer, N.C. [Oregon Graduate Inst. of Science and Technology, Beaverton, OR (United States)

1994-01-01T23:59:59.000Z

71

Inventory of power plants in the United States, 1993  

SciTech Connect

The Inventory of Power Plants in the United States is prepared annually by the Survey Management Division, Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), U.S. Department of Energy (DOE). The purpose of this publication is to provide year-end statistics about electric generating units operated by electric utilities in the United States (the 50 States and the District of Columbia). The publication also provides a 10-year outlook of future generating unit additions. Data summarized in this report are useful to a wide audience including Congress, Federal and State agencies, the electric utility industry, and the general public. Data presented in this report were assembled and published by the EIA to fulfill its data collection and dissemination responsibilities as specified in the Federal Energy Administration Act of 1974 (Public Law 93-275) as amended.

Not Available

1994-12-01T23:59:59.000Z

72

HANDLING FRESH FISH REFRIGERATION OF FISH -PART 2  

E-Print Network (OSTI)

(Fishery Leaflet 427) Cold-Storage Design and Refrigeration Equipment Part 3 (Fisher y Leaflet 429) FactorsHANDLING FRESH FISH REFRIGERATION OF FISH - PART 2 UNITED STATES DEPARTMENT OF THE INTERIOR FISH 428 Washington 25, D, C. December 1956 REFRIGERATION OF FISH - PART TWO HANDLING FRESH FISH By Charles

73

Candidate chemical systems for air cooled, solar powered, absorption air conditioner design. Part II. Solid absorbents, high latent heat refrigerants  

DOE Green Energy (OSTI)

Work done in attempting to qualify absorption refrigeration systems based on refrigerants with intermediate latent heats of vaporization is summarized. In practice, these comprise methanol, ammonia, and methylamine. A wide variety of organic substances, salts, and mixtures were evaluated in as systematic a manner as possible. Several systems of interest are described. The system, LiClO/sub 3/--LiBr--H/sub 2/O, is a good back up system to our first choice of an antifreeze additive system, and thermodynamically promising but subject to some inconvenient materials limitations. The system, LiBr/ZnBr/sub 2/--methanol, is thermodynamically promising but requires additional kinetic qualification. Chemical stability of the system, LiCNS--ammonia/methylamine with various other third components, does not appear to be adequate for a long-lived system.

Biermann, W. J.

1978-04-01T23:59:59.000Z

74

Inventory of Power Plants in the United States, October 1992  

Science Conference Proceedings (OSTI)

The Inventory of Power Plants in the United States is prepared annually by the Survey Management Division, Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), US Department of Energy (DOE). The purpose of this publication is to provide year-end statistics about electric generating units operated by electric utilities in the United States (the 50 States and the District of Columbia). The publication also provides a 10-year outlook of future generating unit additions. Data summarized in this report are useful to a wide audience including Congress, Federal and State agencies, the electric utility industry, and the general public. Data presented in this report were assembled and published by the EIA to fulfill its data collection and dissemination responsibilities as specified in the Federal Energy Administration Act of 1974 (Public Law 93-275) as amended. The report is organized into the following chapters: Year in Review, Operable Electric Generating Units, and Projected Electric Generating Unit Additions. Statistics presented in these chapters reflect the status of electric generating units as of December 31, 1992.

Not Available

1993-10-27T23:59:59.000Z

75

FirstEnergy (West Penn Power) - Commercial and Industrial Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Source Heat Pumps: 250unit Chillers: 12.50-25ton Custom: 0.05kWh saved annually RefrigerationFood Service Equipment: Varies Provider FirstEnergy (West Penn Power)...

76

Fluorescent refrigeration  

DOE Patents (OSTI)

Fluorescent refrigeration is based on selective radiative pumping, using substantially monochromatic radiation, of quantum excitations which are then endothermically redistributed to higher energies. Ultimately, the populated energy levels radiatively deexcite emitting, on the average, more radiant energy than was initially absorbed. The material utilized to accomplish the cooling must have dimensions such that the exciting radiation is strongly absorbed, but the fluorescence may exit the material through a significantly smaller optical pathlength. Optical fibers and mirrored glasses and crystals provide this requirement. 6 figs.

Epstein, R.I.; Edwards, B.C.; Buchwald, M.I.; Gosnell, T.R.

1995-09-05T23:59:59.000Z

77

Wind Power Price Trends in the United States  

SciTech Connect

For the fourth year in a row, the United States led the world in adding new wind power capacity in 2008, and also surpassed Germany to take the lead in terms of cumulative installed wind capacity. The rapid growth of wind power in the U.S. over the past decade (Figure 1) has been driven by a combination of increasingly supportive policies (including the Federal production tax credit (PTC) and a growing number of state renewables portfolio standards), uncertainty over the future fuel costs and environmental liabilities of natural gas and coal-fired power plants, and wind's competitive position among generation resources. This article focuses on just the last of these drivers - i.e., trends in U.S. wind power prices - over the period of strong capacity growth since 1998.

Bolinger, Mark; Wiser, Ryan

2009-07-15T23:59:59.000Z

78

Inventory of power plants in the United States 1994  

SciTech Connect

The Inventory of Power Plants in the US provides year-end statistics on generating units operated by electric utilities in the US (the 50 States and the District of Columbia). Statistics presented in this report reflect the status of generating units as of December 31, 1994. The publication also provides a 10-year outlook for generating unit additions. This report is prepared annually by the Coal and Electric Data and Renewables Division; Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); US Department of Energy (DOE). Data summarized in this report are useful to a wide audience including Congress, Federal, and State agencies; the electric utility industry; and the general public. This is a report of electric utility data; in cases where summary data of nonutility capacity are presented, it is specifically noted as such.

NONE

1995-10-18T23:59:59.000Z

79

Solutions for Summer Electric Power Shortages: Demand Response and its Applications in Air Conditioning and Refrigerating Systems  

E-Print Network (OSTI)

Air Conditioning, & Electric Power Machinery 29(1): 1-4 Solutions for Summer Electric Power Shortages: DemandUSA Solutions for summer electric power shortages: Demand

Han, Junqiao; Piette, Mary Ann

2008-01-01T23:59:59.000Z

80

Advanced IGCC power systems for the United States  

SciTech Connect

Integrated coal gasification combined-cycle (IGCC) power systems offer the potential of superior efficiency and environmental performance over power plants using pulverized coal-fired boilers with scrubbers to generate electricity in the United States. The Cool Water plant is demonstrating the feasibility of an IGCC system using an entrained-bed gasifier and ''cold'' gas cleanup technology. Technology is now being developed to simplify the IGCC system, increase its efficiency and reduce its capital costs. Hot gas sulfur and particulate cleanup is the most promising technology option for the gas supply block. Improved performance is also available from the power island by use of high-efficiency aircraft derivative turbines. Progress in these technologies and the exceptional match of these IGCC systems to the projected needs of the utility industry is presented.

Wieber, P.R.; Halow, J.S.

1986-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

ARTI refrigerant database  

Science Conference Proceedings (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M.

1996-07-01T23:59:59.000Z

82

ARTI refrigerant database  

Science Conference Proceedings (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilities access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M. [Calm (James M.), Great Falls, VA (United States)] [Calm (James M.), Great Falls, VA (United States)

1999-01-01T23:59:59.000Z

83

ARTI refrigerant database  

Science Conference Proceedings (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M.

1996-11-15T23:59:59.000Z

84

Power systems simulations of the western United States region.  

DOE Green Energy (OSTI)

This report documents a part of a broad assessment of energy-water-related issues in the western United States. The full analysis involved three Department of Energy national laboratories: Argonne National Laboratory, Los Alamos National Laboratory, and Sandia National Laboratories. Argonne's objective in the overall project was to develop a regional power sector expansion forecast and a detailed unit-level operational (dispatch) analysis. With these two major analysis components, Argonne estimated current and future freshwater withdrawals and consumption related to the operation of U.S. thermal-electric power plants in the Western Electricity Coordinating Council (WECC) region for the period 2005-2025. Water is withdrawn and used primarily for cooling but also for environmental control, such as sulfur scrubbers. The current scope of the analysis included three scenarios: (1) Baseline scenario as a benchmark for assessing the adequacy and cost-effectiveness of water conservation options and strategies, (2) High nuclear scenario, and (3) High renewables scenario. Baseline projections are consistent with forecasts made by the WECC and the Energy Information Administration (EIA) in its Annual Energy Outlook (AEO) (EIA 2006a). Water conservation scenarios are currently limited to two development alternatives that focus heavily on constructing new generating facilities with zero water consumption. These technologies include wind farms and nuclear power plants with dry cooling. Additional water conservation scenarios and estimates of water use associated with fuel or resource extraction and processing will be developed in follow-on analyses.

Conzelmann, G.; Koritarov, V.; Poch, L.; Thimmapuram, P.; Veselka, T.; Decision and Information Sciences

2010-03-15T23:59:59.000Z

85

Superinsulation in refrigerators and freezers  

SciTech Connect

The results presented here were obtained during Phase 4 of the first CRADA, which had the specific objective of determining the lifetime of superinsulations when installed in simulated refrigerator doors. The second CRADA was established to evaluate and test design concepts proposed to significantly reduce energy consumption in a refrigerator-freezer that is representative of approximately 60% of the US market. The stated goal of this CRADA is to demonstrate advanced technologies which reduce, by 50%, the 1993 National Appliance Energy Conservation Act (NAECA) standard energy consumption for a 20 ft{sup 3} (570 L) top-mount, automatic-defrost, refrigerator-freezer. For a unit this size, the goal translates to an energy consumption of 1.003 kWh/d. The general objective of the research is to facilitate the introduction of efficient appliances by demonstrating design changes that can be effectively incorporated into new products. In previous work on this project, a Phase 1 prototype refrigerator-freezer achieved an energy consumption of 1.413 kWh/d [Vineyard, et al., 1995]. Following discussions with an advisory group comprised of all the major refrigerator-freezer manufacturers, several options were considered for the Phase 2 effort, one of which was cabinet heat load reductions.

Vineyard, E.; Stovall, T.K.; Wilkes, K.E.; Childs, K.W.

1998-02-01T23:59:59.000Z

86

Research of Refrigerant Phase-Change Stirling-Cycle Heat Engines  

Science Conference Proceedings (OSTI)

This paper firstly introduces the principles of Refrigerant Phase-Change Stirling-Cycle solar power towers This heat engines use solar reservoire. When the refrigerant in an engine cylinder absorbs heat from high-temperature heat sources, refrigerant ... Keywords: refrigerant phase-change cycle, heat engines, finite-time thermodynamics

Dezhong Huang; Fuer Wu

2011-01-01T23:59:59.000Z

87

Design of Industrial Process Refrigeration Systems  

E-Print Network (OSTI)

When considering electric driven refrigeration compressors, proper integration with the process may result in reduced power consumption. However, the total utility situation must be considered when evaluating the compressor driver. Conversion from steam drivers to electric drivers may be more economical when considering proper process integration. These questions and various scenarios must be addressed in light of the total process requirements and constraints. During the last few years, Union Carbide has successfully applied ADVENT™ technology to several complex processes that utilize refrigeration systems. In most cases the design of a complex refrigeration system in isolation (i.e., without considering process integration) generally results in non-optimum refrigeration levels and excessive refrigeration consumption. By applying ADVENT™ Process Integration Technologv to these non-optimal designs, retrofit projects have emerged that clearly identify how to optimize the existing design with good project economics. This paper presents the results of an ADVENT Process Integration Study for the Electric Power Research Institute (EPRI) of Palo Alto, California. The study objective was to demonstrate process synthesis techniques for retrofit design in two industrial refrigeration intensive processes: an olefins process and a beer brewery process. Study results for each retrofit design are explained along with generalized guidelines for application to other processes. An industry scoping portion of the study is discussed in terms of identifying refrigeration intensive processes. Specific and general conclusions are presented to help facilitate proper industrial refrigeration system design throughout the industry.

Witherell, W. D.

1987-09-01T23:59:59.000Z

88

Estimates of Refrigerator Loads in Public Housing Based on Metered Consumption Data  

SciTech Connect

The New York Power Authority (NYPA), the New York City Housing Authority (NYCHA), and the U.S. Departments of Housing and Urban Development (HUD) and Energy (DOE) have joined in a project to replace refrigerators in New York City public housing with new, highly energy-efficient models. This project laid the ground work for the Consortium for Energy Efficiency (CEE) and DOE to enable housing authorities throughout the United States to bulk-purchase energy-efficient appliances. DOE helped develop and plan the program through the ENERGY STAR@ Partnerships program conducted by its Pacific Nofiwest National Laboratory (PNNL). PNNL was subsequently asked to conduct the savings evahations for 1996 and 1997. PNNL designed the metering protocol and occupant survey, supplied and calibrated the metering equipment, and managed and analyzed the data. The 1996 metering study of refrigerator energy usage in New York City public housing (Pratt and Miller 1997) established the need and justification for a regression-model-based approach to an energy savings estimate. The need originated in logistical difficulties associated with sampling the population and pen?orming a stratified analysis. Commonly, refrigerators[a) with high representation in the popula- tion were missed in the sampling schedule, leaving significant holes in the sample and difficulties for the stratified anrdysis. The just{jfcation was found in the fact that strata (distinct groups of identical refrigerators) were not statistically distinct in terms of their label ratio (ratio of metered consumption to label rating). This finding suggested a general regression model could be used to represent the consumption of all refrigerators in the population. In 1996 a simple two-coefficient regression model, a function of only the refrigerator label rating, was developed and used to represent the existing population of refrigerators. A key concept used in the 1997 study grew from findings in a small number of apartments metered in 1996 with a detailed protocol. Fifteen-minute time-series data of ambient and compartment temperatures and refrigerator power were analyzed and demonstrated the potential for reducing power records into three components. This motivated the development of an analysis process to divide the metered consumption into baseline load, occupant-associated load, and defrosting load. The baseline load is the consumption that would occur if the refrigerator were on but had no occupant usage load (no door- opening events) and the defrosting mechanism was disabled. The motivation behind this component reduction process was the hope that components could be more effectively modeled than the total. We reasoned that the components would lead to abetter (more general and more significant) understanding of the relationships between consumption, the characteristics of the refrigerator, and its operating environment.

JD Miller; RG Pratt

1998-09-11T23:59:59.000Z

89

Novel La(Fe,Si) 13 -Based Composites for Magnetic Refrigeration  

Science Conference Proceedings (OSTI)

Nanocomposite Alloy Design for High Frequency Power Conversion Applications · Novel La(Fe,Si)13-Based Composites for Magnetic Refrigeration.

90

ARTI Refrigerant Database  

Science Conference Proceedings (OSTI)

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

1994-05-27T23:59:59.000Z

91

Wind Power Development in the United States: Current Progress, Future Trends  

E-Print Network (OSTI)

Annual Report on U.S. Wind Power Installation, Cost, andWind Power Development in the United States: Current94720 Abstract: The U.S. wind power industry is in an era of

Wiser, Ryan H

2009-01-01T23:59:59.000Z

92

The Quantum Absorption Refrigerator  

E-Print Network (OSTI)

A quantum absorption refrigerator driven by noise is studied with the purpose of determining the limitations of cooling to absolute zero. The model consists of a working medium coupled simultaneously to hot, cold and noise baths. Explicit expressions for the cooling power are obtained for Gaussian and Poisson white noise. The quantum model is consistent with the first and second laws of thermodynamics. The third law is quantified, the cooling power J_c vanishes as J_c proportional to T_c^{alpha}, when T_c approach 0, where alpha =d+1 for dissipation by emission and absorption of quanta described by a linear coupling to a thermal bosonic field, where d is the dimension of the bath.

Amikam Levy; Ronnie Kosloff

2011-09-04T23:59:59.000Z

93

Factors driving wind power development in the United States  

SciTech Connect

In the United States, there has been substantial recent growth in wind energy generating capacity, with growth averaging 24 percent annually during the past five years. About 1,700 MW of wind energy capacity was installed in 2001, while another 410 MW became operational in 2002. This year (2003) shows promise of significant growth with more than 1,500 MW planned. With this growth, an increasing number of states are experiencing investment in wind energy projects. Wind installations currently exist in about half of all U.S. states. This paper explores the key factors at play in the states that have achieved a substantial amount of wind energy investment. Some of the factors that are examined include policy drivers, such as renewable portfolio standards (RPS), federal and state financial incentives, and integrated resource planning; as well as market drivers, such as consumer demand for green power, natural gas price volatility, and wholesale market rules.

Bird, Lori A.; Parsons, Brian; Gagliano, Troy; Brown, Matthew H.; Wiser, Ryan H.; Bolinger, Mark

2003-05-15T23:59:59.000Z

94

Evaluation of design options for improving the energy efficiency of an environmentally safe domestic refrigerator-freezer  

SciTech Connect

In order to reduce greenhouse emissions from power plants and respond to regulatory actions arising from the National Appliance Energy Conservation Act (NAECA), several design options were investigated for improving the energy efficiency of a conventionally designed, domestic refrigerator-freezer. The options, such as improved cabinet insulation and high-efficiency compressor and fans, were incorporated into a prototype refrigerator-freezer cabinet and refrigeration system to produce a unit that is superior from an environmental viewpoint due to its lower energy consumption and the use of refrigerant HFC-134a as a replacement for CFC-12. Baseline energy performance of the original 1993 production refrigerator-freezer, along with cabinet heat load and compressor calorimeter test results, were extensively documented to provide a firm basis for experimentally measured energy savings. A detailed refrigerator system computer model was used to evaluate the energy savings for several design modifications that, collectively, could achieve a targeted energy consumption of 1.00 kWh/d for a 20 ft{sup 3} (570 l) top-mount, automatic-defrost, refrigerator-freezer. The energy consumption goal represents a 50% reduction in the 1993 NAECA standard for units of this size. Following the modeling simulation, laboratory prototypes were fabricated and tested to experimentally verify the analytical results and aid in improving the model in those areas where discrepancies occurred. While the 1.00 kWh/d goal was not achieved with the modifications, a substantial energy efficiency improvement of 22% (1.41 kWh/d) was demonstrated using near-term technologies. It is noted that each improvement exacts a penalty in terms of increased cost or system complexity/reliability. Further work on this project will analyze cost-effectiveness of the design changes and investigate alternative, more-elaborate, refrigeration system changes to further reduce energy consumption.

Vineyard, E.A.; Sand, J.R. [Oak Ridge National Lab., TN (United States); Bohman, R.H.

1995-03-01T23:59:59.000Z

95

Helium dilution refrigeration system  

DOE Patents (OSTI)

A helium dilution refrigeration system operable over a limited time period, and recyclable for a next period of operation is disclosed. The refrigeration system is compact with a self-contained pumping system and heaters for operation of the system. A mixing chamber contains [sup 3]He and [sup 4]He liquids which are precooled by a coupled container containing [sup 3]He liquid, enabling the phase separation of a [sup 3]He rich liquid phase from a dilute [sup 3]He-[sup 4]He liquid phase which leads to the final stage of a dilution cooling process for obtaining low temperatures. The mixing chamber and a still are coupled by a fluid line and are maintained at substantially the same level with the still cross sectional area being smaller than that of the mixing chamber. This configuration provides maximum cooling power and efficiency by the cooling period ending when the [sup 3]He liquid is depleted from the mixing chamber with the mixing chamber nearly empty of liquid helium, thus avoiding unnecessary and inefficient cooling of a large amount of the dilute [sup 3]He-[sup 4]He liquid phase. 2 figs.

Roach, P.R.; Gray, K.E.

1988-09-13T23:59:59.000Z

96

Inventory of Nonutility Electric Power Plants in the United States  

Reports and Publications (EIA)

Final issue of this report. Provides annual aggregate statistics on generating units operated by nonutilities in the United States and the District of Columbia. Provides a 5-year outlook for generating unit additions and changes.

Information Center

2003-01-01T23:59:59.000Z

97

UNITED STATES DEPARTMENT OF ENERGY SOUTHWESTERN POWER ADMINISTRATION  

NLE Websites -- All DOE Office Websites (Extended Search)

OF ENERGY SOUTHWESTERN POWER ADMINISTRATION RATE SCHEDULE RDW-12 1 WHOLESALE RATES FOR HYDRO POWER AND ENERGY SOLD TO SAM RAYBURN MUNICIPAL POWER AGENCY (CONTRACT NO....

98

Solutions for Summer Electric Power Shortages: Demand Response and its Applications in Air Conditioning and Refrigerating Systems  

E-Print Network (OSTI)

Research Director, PIER Demand Response Research CenterAssessment of Demand Response & Advanced Metering, staffPower Shortages: Demand Response and its Applications in Air

Han, Junqiao; Piette, Mary Ann

2008-01-01T23:59:59.000Z

99

AMERICAN ELECTRIC POWER'S CONESVILLE POWER PLANT UNIT NO.5 CO2 CAPTURE RETROFIT STUDY  

SciTech Connect

ALSTOM Power Inc.'s Power Plant Laboratories (ALSTOM) has teamed with American Electric Power (AEP), ABB Lummus Global Inc. (ABB), the US Department of Energy National Energy Technology Laboratory (DOE NETL), and the Ohio Coal Development Office (OCDO) to conduct a comprehensive study evaluating the technical feasibility and economics of alternate CO{sub 2} capture and sequestration technologies applied to an existing US coal-fired electric generation power plant. The motivation for this study was to provide input to potential US electric utility actions concerning GHG emissions reduction. If the US decides to reduce CO{sub 2} emissions, action would need to be taken to address existing power plants. Although fuel switching from coal to natural gas may be one scenario, it will not necessarily be a sufficient measure and some form of CO{sub 2} capture for use or disposal may also be required. The output of this CO{sub 2} capture study will enhance the public's understanding of control options and influence decisions and actions by government, regulators, and power plant owners in considering the costs of reducing greenhouse gas CO{sub 2} emissions. The total work breakdown structure is encompassed within three major reports, namely: (1) Literature Survey, (2) AEP's Conesville Unit No.5 Retrofit Study, and (3) Bench-Scale Testing and CFD Evaluation. The report on the literature survey results was issued earlier by Bozzuto, et al. (2000). Reports entitled ''AEP's Conesville Unit No.5 Retrofit Study'' and ''Bench-Scale Testing and CFD Evaluation'' are provided as companion volumes, denoted Volumes I and II, respectively, of the final report. The work performed, results obtained, and conclusions and recommendations derived therefrom are summarized.

Carl R. Bozzuto; Nsakala ya Nsakala; Gregory N. Liljedahl; Mark Palkes; John L. Marion

2001-06-30T23:59:59.000Z

100

PEV-based Reactive Power Compensation for Wind DG Units: A Stackelberg Game Approach  

E-Print Network (OSTI)

turbine's inductive load to ensure a stable voltage profile in the system. Since reactive power can only from the load centers, DG units will speed up the revolution of providing power on site with little unit. Reactive power compensa- tion is needed since the load is not pure resistive and may include

Wu, Chenye

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

End-Use Load and Consumer Assessment Program: Analysis of residential refrigerator/freezer performance  

SciTech Connect

The Bonneville Power Administration (Bonneville) is conducting a large end-use data acquisition program in an effort to understand how energy is utilized in buildings with permanent electric space heating equipment in the Pacific Northwest. The initial portion of effort, known as the End-Use Load and Consumer Assessment Program (ELCAP), was conducted for Bonneville by the Pacific Northwest Laboratory (PNL). The collection of detailed end-use data provided an opportunity to analyze the amount of energy consumed by both refrigerators and separate freezers units located in residential buildings. By obtaining this information, the uncertainty of long- term regional end-use forecasting can be improved and potential utility marketing programs for new appliances with a reduced overall energy demand can be identified. It was found that standby loads derived from hourly averages between 4 a.m. and 5 a.m. reflected the minimum consumption needed to maintain interior refrigerator temperatures at a steady-state condition. Next, an average 24-hour consumption that included cooling loads from door openings and cooling food items was also determined. Later, analyses were conducted to develop a model capable of predicting refrigerator standby loads and 24-hour consumption for comparison with national refrigerator label ratings. Data for 140 residential sites with a refrigeration end-use were screened to develop a sample of 119 residences with pure refrigeration for use in this analysis. To identify those refrigerators that were considered to be pure (having no other devices present on the circuit) in terms of their end-use classification, the screening procedure used a statistical clustering technique that was based on standby loads with 24-hour consumption. 5 refs., 18 figs., 4 tabs.

Ross, B.A.

1991-09-01T23:59:59.000Z

102

Solutions for Summer Electric Power Shortages: Demand Response and its Applications in Air Conditioning and Refrigerating Systems  

E-Print Network (OSTI)

Berkeley, CA94720, USA Summary Demand response (DR) is anVirginia, USA in 1961, female Research Director, PIER DemandUSA Solutions for summer electric power shortages: Demand

Han, Junqiao; Piette, Mary Ann

2008-01-01T23:59:59.000Z

103

Optimizing Cooling Tower Performance Refrigeration Systems, Chemical Plants, and Power Plants All Have A Resource Quietly Awaiting Exploitation-Cold Water!!  

E-Print Network (OSTI)

Cooling towers, because of their seeming simplicity, are usually orphans of the facilities operation. We are all aware that cooling towers are the step-children of the chemical process plant, electric power generating station, and refrigeration system. While engineers are pretty well convinced of the importance of their sophisticated equipment, and rightly so, they take the cooling towers and the cold water returning from them for granted. Design Conditions are specified for the particular requirements before a cooling tower is purchased. This relates to the volume of circulating water, hot water temperature on the tower, cold water discharge, and wet bulb temperature (consisting of ambient temperature and relative humidity). After the tower is put on the line and the cold water temperature or volume becomes inadequate, engineers look to solutions other than the obvious. While all cooling towers are purchased to function at 100% of capability in accordance with the required Design Conditions, in actual on-stream employment, the level of operation many times is lower, downwards to as much as 50% due to a variety of reasons: 1. The present service needed is now greater than the original requirements which the tower was purchased for. 2. “Slippage” due to usage and perhaps deficient maintenance has reduced the performance of the tower over years of operation. 3. The installation could have been originally undersized due to the low bidder syndrome. 4. New plant expansion needs additional water volume and possibly colder temperatures off the tower.

Burger, R.

1991-06-01T23:59:59.000Z

104

Optimizing Cooling Tower Performance- Refrigeration Systems, Chemical Plants, and Power Plants all Have A Resource Quietly Awaiting Exploitation-Cold Water!!  

E-Print Network (OSTI)

Cooling towers, because of their seeming simplicity, are usually orphans of the facilities operation. We are all aware that cooling towers are the step-children of the chemical process plant, electric power generating station, and refrigeration system. While engineers are pretty well convinced of the importance of their sophisticated equipment, and rightly so, they take the cooling towers and the cold water returning from them for granted. Design Conditions are specified for the particular requirements before a cooling tower is purchased. This relates to the volume of circulatlng water, hot water temperature on the tower, cold water temperature discharge, and wet bulb temperature (consisting of ambient temperature and relative humidity). After the tower is put on the line and the cold water temperature or volume becomes inadequate, engineers look to solutions other than the obvious. While all cooling towers are purchased to function at 100% of capability in accordance with the required Design Conditions, in actual on-stream employment, the level of operation many times is lower, downwards to as much as 50% due to a variety of reasons: 1. The present service needed is now greater than the original requirements which the tower was purchased for. 2. "Slippage" due to usage and perhaps deficient maintenance has reduced the performance of the tower over years of operation. 3. The installation could have been originally undersized due to the low bidder syndrome (1). 4. New plant expansion needs additional water volume and possibly colder temperatures off the tower.

Burger, R.

1990-06-01T23:59:59.000Z

105

Backgrounder: Geothermal resource production, steam gathering, and power generation at Salton Sea Unit 3, Calipatria, California  

DOE Green Energy (OSTI)

The 10,000-kilowatt Salton Sea Unit 1 power plant was designed to demonstrate that electrical power generation, using the highly saline brines from the Salton Sea geothermal reservoir, was technically and economically feasible. Unit 1, owned by Earth Energy, a Unocal subsidiary, began operating in 1982, initiating an intensive testing program which established the design criteria necessary to construct the larger 47,500-kilowatt Unit 3 power plant, unit 3 contains many of the proprietary or patented technological innovations developed during this program. Design, construction and start-up of the Unit 3 power generating facility began in December, 1986, and was completed in 26 months. By the end of 1988, the brine handling system was in full operation, and the turbine had been tested at design speed. Desert Power Company, a Unocal subsidiary, owns the power generating facility. Unocal owns the brine resource production facility. Power is transmitted by the Imperial Irrigation District to Southern California Edison Company.

None

1989-04-01T23:59:59.000Z

106

Wind Power Price Trends in the United States  

E-Print Network (OSTI)

price of power from new U.S. wind projects higher in 2009.should eventually help wind power regain the downward pricein Modern Energy Review] Wind Power Price Trends in the

Bolinger, Mark

2010-01-01T23:59:59.000Z

107

Wind Power Price Trends in the United States  

E-Print Network (OSTI)

should eventually help wind power regain the downward priceModern Energy Review] Wind Power Price Trends in the Unitedled the world in adding new wind power capacity in 2008, and

Bolinger, Mark

2010-01-01T23:59:59.000Z

108

Japanese Refrigerators : A Field Performance Analysis : Summary Report.  

SciTech Connect

Society generally expects Japanese refrigerators to be more energy efficient than their American-made counterparts. With increasing attention being focused on appliance energy efficiency, research into operating characteristics of Japanese refrigerators has gained importance. Other projects report the monitored energy use of certain models of Japanese refrigerators. In addition, laboratory tests determined energy consumption of certain refrigerators under controlled conditions. In 1987, Bonneville Power Administration (BPA) undertook a project to measure and analyze the energy consumption of 12 Japanese-made refrigerators in the Portland-Vancouver metropolitan area. This project's purpose was to collect field data on certain models and compare with that collected in other projects and laboratory tests. Japanese energy consumption figures fall 30--40% below those of DOE. This energy savings, if real, could substantially cut baseload power for utilities. Determining typical refrigerator energy use patterns and which environmental factors effect them helps utilities to forecast demand. 7 refs., 1 fig., 1 tab.

Short, John A.

1990-02-01T23:59:59.000Z

109

Inventory of Electric Utility Power Plants in the United States 2000  

U.S. Energy Information Administration (EIA)

DOE/EIA-0095(2000) Inventory of Electric Utility Power Plants in the United States 2000 March 2002 Energy Information Administration Office of Coal, Nuclear, Electric

110

Wind Power Development in the United States: Current Progress, Future Trends  

E-Print Network (OSTI)

and India. The technology has matured and, in good windWind Power Capacity Incremental Capacity (2007, MW) United States China Spain Germany India

Wiser, Ryan H

2009-01-01T23:59:59.000Z

111

Demonstration of Clyde Bergemann Water Cannons at Alabama Power Company's Plant Miller Unit 1  

Science Conference Proceedings (OSTI)

This report documents the findings of a demonstration of Clyde Bergemann Water Cannons at Alabama Power Company's Plant Miller Unit 1.

2004-11-08T23:59:59.000Z

112

Evaluation of Fuel Cell Auxiliary Power Units for Heavy-Duty Diesel Trucks  

E-Print Network (OSTI)

J. , Gottesfeld, S. , 1999. Direct methanol fuel cells.Fuel cells for transportation. 1999 Annual Progress Report.Auxiliary power units; Fuel cells 1. Introduction A large

2002-01-01T23:59:59.000Z

113

Evaluation of Fuel Cell Auxiliary Power Units for Heavy-Duty Diesel Trucks  

E-Print Network (OSTI)

Fuel cells for transportation. 1999 Annual Progress Report.J. , Gottesfeld, S. , 1999. Direct methanol fuel cells.Auxiliary power units; Fuel cells 1. Introduction A large

2002-01-01T23:59:59.000Z

114

Viability of an expanded United States nuclear power program and its effects on energy markets  

E-Print Network (OSTI)

The four biggest energy sources in the United States are coal, crude oil, natural gas, and nuclear power. While coal and nuclear power are produced domestically, more than 70% of crude oil and 20% of natural gas is imported. ...

Khan, Tanzeer S

2006-01-01T23:59:59.000Z

115

How many and what kind of power plants are there in the United ...  

U.S. Energy Information Administration (EIA)

How many and what kind of power plants are there in the United States? There are about 19,023 individual generators at about 6,997 operational power ...

116

Refrigeration system having standing wave compressor  

DOE Patents (OSTI)

A compression-evaporation refrigeration system, wherein gaseous compression of the refrigerant is provided by a standing wave compressor. The standing wave compressor is modified so as to provide a separate subcooling system for the refrigerant, so that efficiency losses due to flashing are reduced. Subcooling occurs when heat exchange is provided between the refrigerant and a heat pumping surface, which is exposed to the standing acoustic wave within the standing wave compressor. A variable capacity and variable discharge pressure for the standing wave compressor is provided. A control circuit simultaneously varies the capacity and discharge pressure in response to changing operating conditions, thereby maintaining the minimum discharge pressure needed for condensation to occur at any time. Thus, the power consumption of the standing wave compressor is reduced and system efficiency is improved.

Lucas, Timothy S. (Glen Allen, VA)

1992-01-01T23:59:59.000Z

117

Impact of High Wind Power Penetration on Hydroelectric Unit Operations  

SciTech Connect

The Western Wind and Solar Integration Study (WWSIS) investigated the operational impacts of very high levels of variable generation penetration rates (up to 35% by energy) in the western United States. This work examines the impact of this large amount of wind penetration on hydroelectric unit operations. Changes in hydroelectric unit operating unit patterns are examined for an aggregation of all hydro generators. The cost impacts of maintaining hydro unit flexibility are assessed and compared for a number of different modes of system operation.

Hodge, B. M.; Lew, D.; Milligan, M.

2011-01-01T23:59:59.000Z

118

Green Power Marketing in the United States: A Status Report (11th Edition)  

Science Conference Proceedings (OSTI)

This report documents green power marketing activities and trends in the United States. It presents aggregate green power sales data for all voluntary purchase markets across the United States. It also provides summary data on utility green pricing programs offered in regulated electricity markets and green power marketing activity in competitive electricity markets, as well as green power sold to voluntary purchasers in the form of renewable energy certificates. Key market trends and issues are also discussed.

Bird, L.; Kreycik, C.; Friedman, B.

2008-10-01T23:59:59.000Z

119

REFRIGERATION OF FISH PART 5 DISTRIBUTION AND MARKETING  

E-Print Network (OSTI)

REFRIGERATION OF FISH· PART 5 DISTRIBUTION AND MARKETING OF FROZEN FISHERY PRODUCTS UNITED STATES in a series of five on "Refrigeration of Fish." Titles of the other four leaflets are: Part 1 (Fishery Leaflet 427) -- Cold-Storage Design and Refrigera- tion Equipnent Part 2 (Fishery Leaflet 428) -- Handling

120

ARTI refrigerant database  

Science Conference Proceedings (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alterative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on various refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

Calm, J.M.

1997-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Regenerator for Magnetic Refrigerants  

Ames Laboratory researchers have developed a new magnetic material that can be used at low temperatures (sub liquid hydrogen) for magnetic refrigerators.

122

China Refrigerator Information Label  

E-Print Network (OSTI)

LBNL-246E China Refrigerator Information Label: Specification Development and Potential Impact Jianhong Cheng China National Institute of Standardization Tomoyuki Sakamoto The Institute of Energy

123

Chemically assisted mechanical refrigeration process  

DOE Patents (OSTI)

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.

Vobach, A.R.

1987-11-24T23:59:59.000Z

124

Chemically assisted mechanical refrigeration process  

DOE Patents (OSTI)

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer (11) at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer (11) to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator (10) to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing he evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator.

Vobach, Arnold R. (6006 Allentown Dr., Spring, TX 77379)

1987-01-01T23:59:59.000Z

125

Chemically assisted mechanical refrigeration process  

DOE Patents (OSTI)

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer (11) at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer (11) to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator (10) to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator.

Vobach, Arnold R. (6006 Allentown Dr., Spring, TX 77389)

1987-01-01T23:59:59.000Z

126

Chemically assisted mechanical refrigeration process  

DOE Patents (OSTI)

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.

Vobach, A.R.

1987-06-23T23:59:59.000Z

127

A compact rotating dilution refrigerator  

E-Print Network (OSTI)

We describe the design and performance of a new rotating dilution refrigerator that will primarily be used for investigating the dynamics of quantized vortices in superfluid 4He. All equipment required to operate the refrigerator and perform experimental measurements is mounted on two synchronously driven, but mechanically decoupled, rotating carousels. The design allows for relative simplicity of operation and maintenance and occupies a minimal amount of space in the laboratory. Only two connections between the laboratory and rotating frames are required for the transmission of electrical power and helium gas recovery. Measurements on the stability of rotation show that rotation is smooth to around 0.001 rad/s up to angular velocities in excess of 2.5 rad/s. The behavior of a high-Q mechanical resonator during rapid changes in rotation has also been investigated.

Fear, M J; Chorlton, D A; Zmeev, D E; Gillott, S J; Sellers, M C; Richardson, P P; Agrawal, H; Batey, G; Golov, A I

2013-01-01T23:59:59.000Z

128

Factors driving wind power development in the United States  

E-Print Network (OSTI)

incentives, and integrated resource planning; as well as market drivers, such as consumer demand for green power, natural gas

Bird, Lori A.; Parsons, Brian; Gagliano, Troy; Brown, Matthew H.; Wiser, Ryan H.; Bolinger, Mark

2003-01-01T23:59:59.000Z

129

Improved taguchi method based contracted capacity optimization for power consumer with self-owned generating units  

Science Conference Proceedings (OSTI)

The paper proposes an improved Taguchi method to determine the best capacity contracts and dispatch the power output of the self-owned generating units from almost infinite combinations. To be achieved are savings of total power expenses of the consumers ... Keywords: capacity contracts, improved Taguchi method, self-owned generating units

Hong-Tzer Yang; Pai-Chun Peng; Chung-His Huang

2007-05-01T23:59:59.000Z

130

Unit-Contingent Power Purchase Agreement and Asymmetric Information About Plant Outage  

Science Conference Proceedings (OSTI)

This paper analyzes a unit-contingent power purchase agreement between an electricity distributor and a power plant. Under such a contract the distributor pays the plant a fixed price if the plant is operational and nothing if plant outage occurs. Pricing ... Keywords: electricity industry, risk allocation, spot market, unit-contingent contract

Owen Q. Wu; Volodymyr Babich

2012-04-01T23:59:59.000Z

131

Heat pump employing optimal refrigerant compressor for low pressure ratio applications  

DOE Patents (OSTI)

What is disclosed is a heat pump apparatus for conditioning a fluid characterized by a fluid handler for circulating the fluid in heat exchange relationship with a refrigerant fluid; two refrigerant heat exchangers; one for effecting the heat exchange with the fluid and a second refrigerant-heat exchange fluid heat exchanger for effecting a low pressure ratio of compression of the refrigerant; a rotary compressor for compressing the refrigerant with low power consumption at the low pressure ratio; at least one throttling valve connecting at the inlet side of heat exchanger in which liquid refrigerant is vaporized; a refrigerant circuit serially connecting the above elements; refrigerant in the circuit; a source of heat exchange fluid; heat exchange fluid circulating device and heat exchange fluid circuit for circulating the heat exchange fluid in heat exchange relationship with the refrigerant.

Ecker, Amir L. (Dallas, TX)

1982-01-01T23:59:59.000Z

132

Solving the Unit Commitment Problem in Power Generation by Primal and Dual Methods \\Lambda  

E-Print Network (OSTI)

deals with the fuel cost optimal scheduling of on/off decisions and output levels for generating unitsSolving the Unit Commitment Problem in Power Generation by Primal and Dual Methods \\Lambda D and results of test runs are reported. 1 Introduction The unit commitment problem in electricity production

Römisch, Werner

133

List of Commercial Refrigeration Equipment Incentives | Open Energy  

Open Energy Info (EERE)

Refrigeration Equipment Incentives Refrigeration Equipment Incentives Jump to: navigation, search The following contains the list of 103 Commercial Refrigeration Equipment Incentives. CSV (rows 1 - 103) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Appalachian Power - Commercial and Industrial Rebate Programs (West Virginia) Utility Rebate Program West Virginia Commercial Industrial Central Air conditioners Chillers Custom/Others pending approval Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Programmable Thermostats Commercial Refrigeration Equipment Ground Source Heat Pumps Yes AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility

134

Green Power Marketing in the United States: A Status Report (2009 Data)  

Science Conference Proceedings (OSTI)

This report documents green power marketing activities and trends in the United States. First, aggregate green power sales data for all voluntary purchase markets across the United States are presented. Next, we summarize data on utility green pricing programs offered in regulated electricity markets; green power marketing activity in competitive electricity markets, as well as green power sold to voluntary purchasers in the form of RECs; and renewable energy sold as greenhouse gas offsets in the United States. Finally, this is followed by a discussion of key market trends and issues. The data presented in this report are based primarily on figures provided to NREL by utilities and independent renewable energy marketers.

Bird, L.; Sumner, J.

2010-09-01T23:59:59.000Z

135

ARTI Refrigerant Database  

Science Conference Proceedings (OSTI)

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on R-32, R-123, R-124, R- 125, R-134a, R-141b, R142b, R-143a, R-152a, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses polyalkylene glycol (PAG), ester, and other lubricants. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits.

Calm, J.M.

1992-04-30T23:59:59.000Z

136

Solar absorption refrigeration system using new working fluid pairs  

Science Conference Proceedings (OSTI)

Absorption refrigeration systems powered by solar energy increasingly attract research interests in the last years. In this study, thermodynamic analyses for different working fluid pairs are performed. A computer simulation model has been developed ... Keywords: NH3-LiNO3, absorption, crystallization, generator, performance, refrigeration, solar energy

Jasim M. Abdulateef; Kamaruzzaman Sopian; M. A. Alghoul; Mohd Yusof Sulaiman; Azami Zaharim; Ibrahim Ahmad

2008-02-01T23:59:59.000Z

137

Inventory of Electric Utility Power Plants in the United States  

Reports and Publications (EIA)

Final issue of this report. Provides detailed statistics on existing generating units operated by electric utilities as of December 31, 2000, and certain summary statistics about new generators planned for operation by electric utilities during the next 5 years.

Information Center

2002-03-01T23:59:59.000Z

138

Characterization of wind power resource in the United States  

E-Print Network (OSTI)

Wind resource in the continental and offshore United States has been reconstructed and characterized using metrics that describe, apart from abundance, its availability, persistence and intermittency. The Modern Era ...

Gunturu, Udaya Bhaskar

139

Green Power Marketing in the United States: A Status Report ...  

NLE Websites -- All DOE Office Websites (Extended Search)

entities include a certain percentage of renewable energy within their power generation mix; the percentages required and eligibility requirements vary among the states. Eligible...

140

Green Power Marketing in the United States: A Status Report ...  

NLE Websites -- All DOE Office Websites (Extended Search)

some REC products blend other renewable energy sources, such as biomass (typically biogas) and solar. Green Power Sales According to data provided by marketers, about 6,000...

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

PureComfort 240 Combined Cooling, Heating, and Power Unit  

Science Conference Proceedings (OSTI)

This report is an interim case study of a PureComfort 240 combined cooling, heating and power project at the University of Toronto, Mississauga.

2006-03-28T23:59:59.000Z

142

Factors driving wind power development in the United States  

E-Print Network (OSTI)

for green power, natural gas price volatility, and wholesalethe past several years, natural gas prices have experiencedonly from inflated natural gas prices but also from supply-

Bird, Lori A.; Parsons, Brian; Gagliano, Troy; Brown, Matthew H.; Wiser, Ryan H.; Bolinger, Mark

2003-01-01T23:59:59.000Z

143

Geothermal absorption refrigeration for food processing industries. Final report, December 13, 1976--November 13, 1977  

DOE Green Energy (OSTI)

The first step in the economic analysis of the integration of geothermally powered absorption refrigeration into a food processing plant was an evaluation of the potential geothermal sites in the Western United States. The evaluation covered availability of raw materials, transportation, adequate geothermal source, labor, and other requirements for food processing plants. Several attractive geothermal sites were identified--Raft River, Idaho; Sespe Hot Springs, California; Vale Hot Springs, Oregon; Weisler-Crane Creek, Idaho; Cosco Hot Springs, California; and the Imperial Valley, California. The most economically attractive food processing industry was then matched to the site based on its particular energy, raw material, and transportation requirements. The more promising food processors identified were for frozen potato or vegetable products, freeze-dried products, and meat processing. For the refrigeration temperature range of +32/sup 0/F to -40/sup 0/F and geothermal temperature range of 212/sup 0/F to 300/sup 0/F, an absorption refrigeration system had to be identified, designed, and evaluated. Both the conventional ammonia/water and an organic absorption refrigeration system using monochlorodifluoromethane (R-22) as the refrigerant and dimethyl formamide (DMF) as the absorbent were studied. In general, only a 60/sup 0/F to 100/sup 0/F temperature drop would be effectively used for refrigeration leaving the remainder of the allowable temperature drop available for other use. The economic evaluation of the geothermal system installed in a food processing plant required the comparison of several principal alternatives. These alternatives were evaluated for three different food processing plants located at their optimum geothermal site: a forzen potato product processing plant located at Raft River, Idaho; a freeze-dried product plant located at Sespe Hot Springs, California; a beef slaughter operation located in the Imperial Valley of California. (JGB)

Harris, R.L.; Olson, G.K.; Mah, C.S.; Bujalski, J.H.

1977-11-01T23:59:59.000Z

144

NRELs Energy-Saving Technology for Air Conditioning Cuts Peak Power Loads Without Using Harmful Refrigerants (Fact Sheet), NREL (National Renewable Energy Laboratory)  

NLE Websites -- All DOE Office Websites (Extended Search)

DEVAP Slashes Peak Power Loads DEVAP Slashes Peak Power Loads Desiccant-enhanced evaporative (DEVAP) air-condi- tioning will provide superior comfort for commercial buildings in any climate at a small fraction of the elec- tricity costs of conventional air-conditioning equip- ment, releasing far less carbon dioxide and cutting costly peak electrical demand by an estimated 80%. Air conditioning currently consumes about 15% of the electricity generated in the United States and is a major contributor to peak electrical demand on hot summer days, which can lead to escalating power costs, brownouts, and rolling blackouts. DEVAP employs an innovative combination of air-cooling technologies to reduce energy use by up to 81%. DEVAP also shifts most of the energy needs to thermal energy sources, reducing annual electricity use by up

145

and R.Weiss, Framework for power aware remote processing: Design and implementation of a dynamic power estimation unit  

E-Print Network (OSTI)

In this paper we present a “Framework for Power Aware Remote Processing ‘ ‘ to minimize the energy consumption of mobile devices transparently. The main difference to remote processing frameworks already published consists in a novel integrated dynamic Power Estimation Unit. This is an adaptive power consumption estimator, which estimates the energy consumption of sojiware and system components. Based on the estimated power consumption an intelligent power manager migrates software components from the mobile device to remote machines, thus reducing the energy consumption of the mobile device.

Gerald Kaefer; Josef Haid; Bemd Hofer; Gerhard Schall; Reinhold Weiss

2001-01-01T23:59:59.000Z

146

Refrigerated cryogenic envelope  

DOE Patents (OSTI)

An elongated cryogenic envelope including an outer tube and an inner tube coaxially spaced within said inner tube so that the space therebetween forms a vacuum chamber for holding a vacuum. The inner and outer tubes are provided with means for expanding or contracting during thermal changes. A shield is located in the vacuum chamber intermediate the inner and outer tubes; and, a refrigeration tube for directing refrigeration to the shield is coiled about at least a portion of the inner tube within the vacuum chamber to permit the refrigeration tube to expand or contract along its length during thermal changes within said vacuum chamber.

Loudon, John D. (Boulder, CO)

1976-11-16T23:59:59.000Z

147

Thermoacoustic engines and refrigerators  

SciTech Connect

This report is a transcript of a practice lecture given in preparation for a review lecture on the operation of thermoacoustic engines and refrigerators. The author begins by a brief review of the thermodynamic principles underlying the operation of thermoacoustic engines and refrigerators. Remember from thermodynamics class that there are two kinds of heat engines, the heat engine or the prime mover which produces work from heat, and the refrigerator or heat pump that uses work to pump heat. The device operates between two thermal reservoirs at temperatures T{sub hot} and T{sub cold}. In the heat engine, heat flows into the device from the reservoir at T{sub hot}, produces work, and delivers waste heat into the reservoir at T{sub cold}. In the refrigerator, work flows into the device, lifting heat Q{sub cold} from reservoir at T{sub cold} and rejecting waste heat into the reservoir at T{sub hot}.

Swift, G.

1996-12-31T23:59:59.000Z

148

High temperature refrigerator  

SciTech Connect

A high temperature magnetic refrigerator which uses a Stirling-like cycle in which rotating magnetic working material is heated in zero field and adiabatically magnetized, cooled in high field, then adiabatically demagnetized. During this cycle said working material is in heat exchange with a pumped fluid which absorbs heat from a low temperature heat source and deposits heat in a high temperature reservoir. The magnetic refrigeration cycle operates at an efficiency 70% of Carnot.

Steyert, Jr., William A. (Los Alamos, NM)

1978-01-01T23:59:59.000Z

149

Mathematical model of steam generator feed system at power unit of nuclear plant  

Science Conference Proceedings (OSTI)

A mathematical model of a steam generator feed system at a power unit of a nuclear plant with variable values of transfer function coefficients is presented. The model is realized in the MATLAB/Simulink/Stateflow event-driven simulation.

E. M. Raskin; L. A. Denisova; V. P. Sinitsyn; Yu. V. Nesterov

2011-05-01T23:59:59.000Z

150

The future of nuclear power in the United States : economic and regulatory challenges  

E-Print Network (OSTI)

This paper examines the economic and regulatory challenges that must be faced by potential investors in new nuclear power plants in the United States. The historical development of the existing fleet of over 100 nuclear ...

Joskow, Paul L.

2006-01-01T23:59:59.000Z

151

Land-Use Requirements for Solar Power Plants in the United States  

NLE Websites -- All DOE Office Websites (Extended Search)

Land-Use Requirements for Solar Power Plants in the United States Sean Ong, Clinton Campbell, Paul Denholm, Robert Margolis, and Garvin Heath Technical Report NRELTP-6A20-56290...

152

City Water Light and Power - Residential Energy Efficiency Rebate Programs  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

City Water Light and Power - Residential Energy Efficiency Rebate City Water Light and Power - Residential Energy Efficiency Rebate Programs City Water Light and Power - Residential Energy Efficiency Rebate Programs < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Maximum Rebate Refrigerator Recycling: 2 units Insulation: $1,000 Program Info State Illinois Program Type Utility Rebate Program Rebate Amount Clothes Washer: $150 Central Air Conditioner: $9 per kBTUh Air-Source Heat Pumps: $300/ton Geothermal Heat Pump: $500 Refrigerator Recycling: $50 per appliance Insulation: 30% Provider Energy Services Office City Water Light and Power (CWLP) offers rebates to Springfield residential

153

Waste Heat Recapture from Supermarket Refrigeration Systems  

DOE Green Energy (OSTI)

The objective of this project was to determine the potential energy savings associated with improved utilization of waste heat from supermarket refrigeration systems. Existing and advanced strategies for waste heat recovery in supermarkets were analyzed, including options from advanced sources such as combined heat and power (CHP), micro-turbines and fuel cells.

Fricke, Brian A [ORNL

2011-11-01T23:59:59.000Z

154

DOE Releases Comprehensive Report on Offshore Wind Power in the United  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Releases Comprehensive Report on Offshore Wind Power in the DOE Releases Comprehensive Report on Offshore Wind Power in the United States DOE Releases Comprehensive Report on Offshore Wind Power in the United States October 7, 2010 - 12:00am Addthis Washington, D.C. - U.S. Energy Secretary Steven Chu announced today the release of a report from the Department of Energy's National Renewable Energy Laboratory (NREL), which comprehensively analyzes the key factors impacting the deployment of offshore wind power in the U.S. The report, "Large-Scale Offshore Wind Power in the United States: Assessment of Opportunities and Barriers," includes a detailed assessment of the Nation's offshore wind resources and offshore wind industry, including future job growth potential. The report also analyzes the technology challenges,

155

DOE Releases Comprehensive Report on Offshore Wind Power in the United  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Comprehensive Report on Offshore Wind Power in the Comprehensive Report on Offshore Wind Power in the United States DOE Releases Comprehensive Report on Offshore Wind Power in the United States October 7, 2010 - 12:00am Addthis Washington, D.C. - U.S. Energy Secretary Steven Chu announced today the release of a report from the Department of Energy's National Renewable Energy Laboratory (NREL), which comprehensively analyzes the key factors impacting the deployment of offshore wind power in the U.S. The report, "Large-Scale Offshore Wind Power in the United States: Assessment of Opportunities and Barriers," includes a detailed assessment of the Nation's offshore wind resources and offshore wind industry, including future job growth potential. The report also analyzes the technology challenges, economics, permitting procedures, and the potential risks and benefits of

156

Removing Odors from Refrigerators and Freezers after Food has Spoiled  

E-Print Network (OSTI)

If food has spoiled in a refrigerator or freezer because of a power outage or some other reason, undesirable odors can result. This publication explains how to eliminate odors from these appliances.

FCS Project Team - FDRM UNIT

2005-09-30T23:59:59.000Z

157

Test of fusible insulation for a proposed isotope power unit  

SciTech Connect

In support of the Isotope Kilowatt Program, an evaluation test of the full-scale simulated thermoelectric power generation system was made. The test was run with 6.5 in. of fusible insulation around the heat block-shield to determine the system heat losses. A loss of 10% of full power was obtained with the system operation at a heat block-shield surface temperature of 1100 deg F and an argon pressure of 1.0 psig. A test was run to determine the thermal coupling between the heat block-shield and 12 heat pipes with 12 simulated thermoelectric generators. A heat pipe condenser temperature of 1040 deg F was obtained at a heat block-shield surface temperature of 1150 deg F at a total power input of 34 kW. A loss-of-coolant accident test was made to determine the maximum fuel capsule surface temperature reached during a meltdown of the fusible insulation. The meltdown results yielded a maximum fuel capsule surface temperature of 2175 deg F and an equilibrium temperature of 2070 deg F. (auth)

Lackey, M.E.

1974-04-01T23:59:59.000Z

158

Modeling of Electronically Commutated Motor Controlled Fan-powered Terminal Units  

E-Print Network (OSTI)

Empirical models of airflow and power consumption were developed for series and parallel variable air volume fan powered terminal units (FPTUs). An experimental setup and test procedure were developed to test the terminal units over typical operating ranges. The terminal units in this study used either an 8 in. (20.32 cm) or a 12 in. (30.48 cm) primary air inlet. All terminal units utilized electronically commutated motor (ECM) controllers. Data collected were compared against previous data collected for silicon controlled rectifier (SCR) units. Generalized models were developed for both series and parallel units, and compared against models developed for SCR units. In addition to the performance modeling, power factor and power quality data were also collected for each terminal unit. The power quality analysis included recording and analyzing harmonic distortion for current, voltage, and power up to the 25th harmonic. The total harmonic distortion (THD) was also recorded and presented. For the series terminal units, models were developed for fan airflow, fan power, and primary airflow. The models for fan airflow all had R2 values above 0.987. The models for fan power all had R2 values above 0.968. The models for primary airflow all had R2 values above 0.895. For the parallel terminal units, models were developed for leakage, fan airflow, fan power, and primary airflow. All of the leakage models had R2 values above 0.826. All of the fan airflow models had R2 values above 0.955. All of the fan power models had R2 values above 0.922. All of the primary airflow models had R2 values above 0.872. The real power THD was below 1.5 percent for both series and parallel FPTUs. The current THD ranged from 84 percent to 172 percent for series FPTUs and from 83 percent to 183 percent for parallel FPTUs. The voltage THD was below 1.4 percent for both series and parallel FPTUs. The performance models developed will help improve the accuracy of building energy simulation programs for heating, ventilation, and air conditioning (HVAC) systems utilizing ECM controlled FPTUs. Increasing the accuracy of these simulations will allow HVAC system designers to better optimize their designs for specific building types in a wide variety of climates.

Edmondson, Jacob Lee

2009-12-01T23:59:59.000Z

159

Energy Saving with Absorption Refrigeration Technologies  

E-Print Network (OSTI)

Absorption refrigeration technology can be an economical and cost effective means of reducing energy cost and/or improving the efficiency and output of your process. We believe the potential benefits of absorption refrigeration technology have generally been overlooked by the process industry. This paper will address the application of the lithium bromide-water cycle in various energy saving modes. A waste heat powered absorption chiller producing chilled water can reduce energy consumption in a process plant by replacing an existing mechanical refrigeration system or replacing cooling tower water with a lower temperature cooling medium at negligible increase in energy cost. A variety of waste heat sources can be used at temperatures as low as 150 F.

Davis, R. C.

1984-01-01T23:59:59.000Z

160

Solar refrigeration in rural West Bengal: Design of a product service system.  

E-Print Network (OSTI)

??Solarbear is a refrigerator that cools with the heat of the sun only. This technology, more formally known as solar powered adsorption cooling, has been… (more)

Van Genuchten, R.P.

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Non-intrusive refrigerant charge indicator - Energy ...  

... -phase refrigerant line section. The measured temperature can be used to determine the refrigerant charge status of an HVAC system, ...

162

Demand Response Opportunities in Industrial Refrigerated Warehouses...  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Response Opportunities in Industrial Refrigerated Warehouses in California Title Demand Response Opportunities in Industrial Refrigerated Warehouses in California...

163

AEO2011: Electric Power Projections for EMM Region - United States | OpenEI  

Open Energy Info (EERE)

United States United States Dataset Summary Description This dataset comes from the Energy Information Administration (EIA), and is part of the 2011 Annual Energy Outlook Report (AEO2011). This dataset is table 95, and contains only the reference case. The data is broken down into electric power sector, cumulative planned additions,cumulative unplanned additions,cumulative retirements, end-use sector, electricity sales, net energy for load, generation by fuel type and price by service category. Source EIA Date Released April 26th, 2011 (3 years ago) Date Updated Unknown Keywords 2011 AEO EIA Electric Power projections United States Data application/vnd.ms-excel icon AEO2011: Electric Power Projections for EMM Region - United States- Reference Case (xls, 260.9 KiB) Quality Metrics

164

Overview of commercialization of stationary fuel cell power plants in the United States  

DOE Green Energy (OSTI)

In this paper, DOE`s efforts to assist private sector organizations to develop and commercialize stationary fuel cell power plants in the United States are discussed. The paper also provides a snapshot of the status of stationary power fuel cell development occurring in the US, addressing all fuel cell types. This paper discusses general characteristics, system configurations, and status of test units and demonstration projects. The US DOE, Morgantown Energy Technology Center is the lead center for implementing DOE`s program for fuel cells for stationary power.

Hooie, D.T.; Williams, M.C.

1995-07-01T23:59:59.000Z

165

Effect of parasitic refrigeration on the efficiency of magnetic liquefiers  

SciTech Connect

Our studies have shown that magnetic refrigerators have the potential to liquefy cryogens very efficiently. High efficiency is especially important for liquid hydrogen and natural gas applications where the liquefaction costs are a significant fraction of the total liquid cost. One of the characteristics of magnetic refrigerators is the requirement for a high-field superconducting magnet. Providing a 4.2-K bath for this magnet will require a small amount of parasitic refrigeration at 4.2 K even though the rest of the liquefier may be at 110 K (liquid natural gas) or higher. For several different refrigeration power levels at 4.2 K, we have calculated the efficiency of the magnetic liquefier as a function of power, temperature and the 4.2-K refrigerator efficiency. The results show that if the ratio of the thermal load at 4.2 K to the main refrigerator power is 0.001 or less, the effect on the efficiency of the liquefier is negligible at all temperatures below room temperature provided the 4.2-K refrigerator efficiency is high.

Barclay, J.A.; Stewart, W.F.

1982-01-01T23:59:59.000Z

166

ARTI Refrigerant Database  

SciTech Connect

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents to accelerate availability of the information and will be completed or replaced in future updates.

Cain, J.M. (Calm (James M.), Great Falls, VA (United States))

1993-04-30T23:59:59.000Z

167

The Future Potential of Waver Power in the United States  

Science Conference Proceedings (OSTI)

The theoretical ocean wave energy resource potential exceeds 50% of the annual domestic energy demand of the United States, is located close to coastal population centers, and, although variable in nature, may be more consistent and predictable than some other renewable generation technologies. As a renewable electricity generation technology, ocean wave energy offers a low air pollutant option for diversifying the U.S. electricity generation portfolio. Furthermore, the output characteristics of these technologies may complement other renewable technologies. This study addresses the following: (1) The theoretical, technical and practical potential for electricity generation from wave energy (2) The present lifecycle cost profile (Capex, Opex, and Cost of Electricity) of wave energy conversion technology at a reference site in Northern California at different plant scales (3) Cost of electricity variations as a function of deployment site, considering technical, geo-spatial and and electric grid constraints (4) Technology cost reduction pathways (5) Cost reduction targets at which the technology will see significant deployment within US markets, explored through a series of deployment scenarios RE Vision Consulting, LLC (RE Vision), engaged in various analyses to establish current and future cost profiles for marine hydrokinetic (MHK) technologies, quantified the theoretical, technical and practical resource potential, performed electricity market assessments and developed deployment scenarios. RE Vision was supported in this effort by NREL analysts, who compiled resource information, performed analysis using the ReEDSa model to develop deployment scenarios, and developed a simplified assessment of the Alaska and Hawaii electricity markets.

Mirko Previsic; Jeff Epler; Maureen Hand; Donna Heimiller; Walter Short; Kelly Eurek

2012-09-20T23:59:59.000Z

168

Wind Power Price Trends in the United States: Struggling to Remain Competitive in the Face of Strong Growth  

E-Print Network (OSTI)

Build a Durable Market for Wind Power in the United States”Learning Curves for Wind Power. ” Energy Policy, 30: 1181-Annual Report on U.S. Wind Power Installation, Cost, and

Bolinger, Mark A

2009-01-01T23:59:59.000Z

169

Toxicity Data to Determine Refrigerant Concentration Limits  

SciTech Connect

This report reviews toxicity data, identifies sources for them, and presents resulting exposure limits for refrigerants for consideration by qualified parties in developing safety guides, standards, codes, and regulations. It outlines a method to calculate an acute toxicity exposure limit (ATEL) and from it a recommended refrigerant concentration limit (RCL) for emergency exposures. The report focuses on acute toxicity with particular attention to lethality, cardiac sensitization, anesthetic and central nervous system effects, and other escape-impairing effects. It addresses R-11, R-12, R-22, R-23, R-113, R-114, R-116, R-123, R-124, R-125, R-134, R-134a, R-E134, R-141b, R-142b, R-143a, R-152a, R-218, R-227ea, R-236fa, R-245ca, R-245fa, R-290, R-500, R-502, R-600a, R-717, and R-744. It summarizes additional data for R-14, R-115, R-170 (ethane), R-C318, R-600 (n-butane), and R-1270 (propylene) to enable calculation of limits for blends incorporating them. The report summarizes the data a nd related safety information, including classifications and flammability data. It also presents a series of tables with proposed ATEL and RCL concentrations-in dimensionless form and the latter also in both metric (SI) and inch-pound (IP) units of measure-for both the cited refrigerants and 66 zerotropic and azeotropic blends. They include common refrigerants, such as R-404A, R-407C, R-410A, and R-507A, as well as others in commercial or developmental status. Appendices provide profiles for the cited single-compound refrigerants and for R-500 and R-502 as well as narrative toxicity summaries for common refrigerants. The report includes an extensive set of references.

Calm, James M.

2000-09-30T23:59:59.000Z

170

Proceedings: Commercial Refrigeration Research Workshop  

Science Conference Proceedings (OSTI)

Improving refrigeration systems for commercial use can enhance both utility load factors and supermarket profits. This workshop has pinpointed research needs in commercial refrigeration and systems integration for a supermarket environment.

1984-10-01T23:59:59.000Z

171

COLD STORAGE DESIGN REFRIGERATION EQUIPMENT  

E-Print Network (OSTI)

COLD STORAGE DESIGN AND REFRIGERATION EQUIPMENT REFRIGERATION OF FISH - PART 1 \\ "..\\- ,,, T I Fishery Leaflet 427 Washington 25, D. C. June 1956 REFRIGERATION OF FISH - PART em; COlD STORAGE DESIGN · · · · · 18 Specific design features 0 0 · · · · · · · · · · · · · · 19 Refrigerated surfaces 0 · · 0 0 0 · 0

172

Adsorption Refrigeration System  

SciTech Connect

Adsorption refrigeration is an environmentally friendly cooling technology which could be driven by recovered waste heat or low-grade heat such as solar energy. In comparison with absorption system, an adsorption system has no problems such as corrosion at high temperature and salt crystallization. In comparison with vapor compression refrigeration system, it has the advantages of simple control, no moving parts and less noise. This paper introduces the basic theory of adsorption cycle as well as the advanced adsorption cycles such as heat and mass recovery cycle, thermal wave cycle and convection thermal wave cycle. The types, characteristics, advantages and drawbacks of different adsorbents used in adsorption refrigeration systems are also summarized. This article will increase the awareness of this emerging cooling technology among the HVAC engineers and help them select appropriate adsorption systems in energy-efficient building design.

Wang, Kai [ORNL; Vineyard, Edward Allan [ORNL

2011-01-01T23:59:59.000Z

173

ARTI Refrigerant Database  

Science Conference Proceedings (OSTI)

The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R- 717 (ammonia), ethers, and others as well as azeotropic and zeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents on compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. A computerized version is available that includes retrieval software.

Calm, J.M.

1992-11-09T23:59:59.000Z

174

Design and development of a wheelchair-accessible, residential refrigeration device: A Case Study of a Technical Assistance Project administered through the  

E-Print Network (OSTI)

Design and development of a wheelchair-accessible, residential refrigeration device: A Case Study Refrigeration unit with transparent doors US Patent. D517572 - Filed Dec 6, 2004 United States Design Patent perishable items from a conventional refrigerator, Dr. John Imre, Chippewa Falls, WI, produced a design and

Wu, Mingshen

175

Low-temperature magnetic refrigerator  

DOE Patents (OSTI)

The invention relates to magnetic refrigeration and more particularly to low temperature refrigeration between about 4 and about 20 K, with an apparatus and method utilizing a belt of magnetic material passed in and out of a magnetic field with heat exchangers within and outside the field operably disposed to accomplish refrigeration.

Barclay, J.A.

1983-05-26T23:59:59.000Z

176

Hybrid refrigeration/sorption solar-cooling systems  

DOE Green Energy (OSTI)

The hybrid refrigeration/sorption concept is a technically feasible approach to solar cooling which has not yet been systematically evaluated. Various system configurations are possible, each with advantages and disadvantages relative to the others, and with respect to solar cooling systems based on the individual absorption, Rankine, and desiccant technologies. Conventional cooling and dehumidification, sorption dehumidification, and the effects on the refrigeration unit of adding a dehumidifier are discussed.

Curran, H.M.

1981-08-01T23:59:59.000Z

177

Heat pump/refrigerator using liquid working fluid  

DOE Patents (OSTI)

A heat transfer device is described that can be operated as a heat pump or refrigerator, which utilizes a working fluid that is continuously in a liquid state and which has a high temperature-coefficient of expansion near room temperature, to provide a compact and high efficiency heat transfer device for relatively small temperature differences as are encountered in heating or cooling rooms or the like. The heat transfer device includes a pair of heat exchangers that may be coupled respectively to the outdoor and indoor environments, a regenerator connecting the two heat exchangers, a displacer that can move the liquid working fluid through the heat exchangers via the regenerator, and a means for alternately increasing and decreasing the pressure of the working fluid. The liquid working fluid enables efficient heat transfer in a compact unit, and leads to an explosion-proof smooth and quiet machine characteristic of hydraulics. The device enables efficient heat transfer as the indoor-outdoor temperature difference approaches zero, and enables simple conversion from heat pumping to refrigeration as by merely reversing the direction of a motor that powers the device.

Wheatley, John C. (Del Mar, CA); Paulson, Douglas N. (Del Mar, CA); Allen, Paul C. (Solana Beach, CA); Knight, William R. (Corvallis, OR); Warkentin, Paul A. (San Diego, CA)

1982-01-01T23:59:59.000Z

178

Yonghuang Therm Power Plant Units 1 and 2, Inchon, South Korea  

SciTech Connect

Because South Korea depends heavily on imported fuels, its government continues to encourage energy diversification. Today Korea has about 60,000 MW of installed capacity that is fueled equally by coal, liquefied natural gas, and nuclear fission. Although the linchpins of the ongoing diversification program are more nukes and more plants powered by imported LNG, another piece of the plan is to make greater use of the country's domestic coal supplies. That is where Korea South-East Power Co. enters the picture, with two new supercritical units that showcase the technology's 40% efficiency. The plant has two 800-MW units and two identical units are under construction at the site. The plant has two-stage combustion and low NOx burners followed by selective catalytic reduction on each unit. SOx emissions are under 45 ppm. An integrated control and monitoring system helps keep down operating costs. 5 figs., 2 tabs.

Peltier, R.

2005-08-01T23:59:59.000Z

179

Diesel-fueled solid oxide fuel cell auxiliary power units for heavy-duty vehicles  

DOE Green Energy (OSTI)

This paper explores the potential of solid oxide fuel cells (SOFCS) as 3--10 kW auxiliary power units for trucks and military vehicles operating on diesel fuel. It discusses the requirements and specifications for such units, and the advantages, challenges, and development issues for SOFCS used in this application. Based on system design and analysis, such systems should achieve efficiencies approaching 40% (lower heating value), with a relatively simple system configuration. The major components of such a system are the fuel cell stack, a catalytic autothermal reformer, and a spent gas burner/air preheater. Building an SOFC-based auxiliary power unit is not straightforward, however, and the tasks needed to develop a 3--10 kW brassboard demonstration unit are outlined.

Krause, T.; Kumar, R.; Krumpelt, M.

2000-05-15T23:59:59.000Z

180

A Roadmap to Deploy New Nuclear Power Plants in the United States by 2010:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

A Roadmap to Deploy New Nuclear Power Plants in the United States A Roadmap to Deploy New Nuclear Power Plants in the United States by 2010: Volume II, Main Report A Roadmap to Deploy New Nuclear Power Plants in the United States by 2010: Volume II, Main Report The objective of this document is to provide the Department of Energy (DOE) and the nuclear industry with the basis for a plan to ensure the availability of near-term nuclear energy options that can be in operation in the U.S. by 2010. This document identifies the technological, regulatory, and institutional gaps and issues that need to be addressed for new nuclear plants to be deployed in the U.S. in this timeframe. It also identifies specific designs that could be deployed by 2010, along with the actions and resource requirements that are needed to ensure their

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

A Roadmap to Deploy New Nuclear Power Plants in the United States by 2010:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

A Roadmap to Deploy New Nuclear Power Plants in the United States A Roadmap to Deploy New Nuclear Power Plants in the United States by 2010: Volume II, Main Report A Roadmap to Deploy New Nuclear Power Plants in the United States by 2010: Volume II, Main Report The objective of this document is to provide the Department of Energy (DOE) and the nuclear industry with the basis for a plan to ensure the availability of near-term nuclear energy options that can be in operation in the U.S. by 2010. This document identifies the technological, regulatory, and institutional gaps and issues that need to be addressed for new nuclear plants to be deployed in the U.S. in this timeframe. It also identifies specific designs that could be deployed by 2010, along with the actions and resource requirements that are needed to ensure their

182

Grid Impacts of Wind Power: A Summary of Recent Studies in the United States; Preprint  

DOE Green Energy (OSTI)

Several detailed technical investigations of grid ancillary service impacts of wind power plants in the United States have recently been performed. These studies were applied to Xcel Energy (in Minnesota) and PacifiCorp and the Bonneville Power Administration (both in the northwestern United States). Although the approaches vary, three utility time frames appear to be most at issue: regulation, load following, and unit commitment. This paper describes and compares the analytic frameworks from recent analysis and discusses the implications and cost estimates of wind integration. The findings of these studies indicate that relatively large-scale wind generation will have an impact on power system operation and costs, but these impacts and costs are relatively low at penetration rates that are expected over the next several years.

Parsons, B.; Milligan, M.; Zavadil, B.; Brooks, D.; Kirby, B.; Dragoon, K.; Caldwell, J.

2003-06-01T23:59:59.000Z

183

Tri-State Generation and Transmission Association's Springverville unit 3 earns POWER's highest honor  

Science Conference Proceedings (OSTI)

It is said that pioneers take the arrows. In the case of Springerville Unit 3 - a 418 MW(net) expansion of a Tucson Electric Power facility in Arizona and the first pulverized coal-fired units built in the US in more than decade, the arrows were many. Although Tri-State (the developer), Tuscon Electric (the host), and Bechtel Power (the EPC contractor) were wounded by delayed deliveries of major equipment, bankruptcy of a major supplier, and a labor shortage, the companies showed their pioneering spirit and completed the project ahead of schedule. For ushering in a new generation of clean and desperately needed baseload capacity, Springerville Unit 3 is POWER magazine's 2006 Plant of the Year. 9 figs.

Peltier, R.

2006-09-15T23:59:59.000Z

184

A Reliability Improvement Program Planning Report for the SNAP 10A Space Nuclear Power Unit  

SciTech Connect

The estimated achieved reliability of SNAP 10A space nuclear power units will be relatively low at the timeof the first SNAPSHOT flight test in April 1963 and the existing R&D program does not provide a significant reliabiity growth thereafter. The total costs of an 8-satellite network using SNAP 10A units over a 5-year period has been approximated for the case where the total cost of a single satellite launched is 8 million dollars.

Coombs, M.G.; Smith C.K.; Wilson, L.A.

1961-03-14T23:59:59.000Z

185

Inventory of power plants in the United States as of January 1, 1996  

DOE Green Energy (OSTI)

The Inventory of Power Plants in the United States provides annual statistics on generating units operated by electric utilities in the United States (the 50 States and the District of Columbia). Statistics presented in this report reflect the status of generating units as of January 1, 1996. The publication also provides a 10-year outlook for generating unit additions. This report is prepared annually by the Coal and Electric Data and Renewables Division; Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); U.S. Department of Energy (DOE). Data summarized in this report are useful to a wide audience including Congress; Federal and State agencies; the electric utility industry; and the general public. Data presented in this report were assembled and published by the EIA to fulfill its data collection and dissemination responsibilities as specified in the Federal Energy Administration Act of 1974 as amended.

NONE

1996-12-01T23:59:59.000Z

186

Inventory of power plants in the United States as of January 1, 1997  

Science Conference Proceedings (OSTI)

The Inventory of Power Plants in the United States provides annual statistics on generating units operated by electric utilities in the United States (the 50 States and the District of Columbia). Statistics presented in this report reflect the status of generating units as of January 1, 1997. The publication also provides a 10-yr outlook for generating unit additions. This report is prepared annually by the Coal and Electric Data and Renewables Division; Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); U.S. Department of Energy (DOE). Data summarized in this report are useful to a wide audience including Congress; Federal and State agencies; the electric utility industry; and the general public. Data presented in this report were assembled and published by the EIA to fulfill its data collection and dissemination responsibilities as specified in the Federal Energy Administration Act of 1974 (Public Law 93-275) as amended.

NONE

1997-12-01T23:59:59.000Z

187

Inventory of power plants in the United States as of January 1, 1998  

Science Conference Proceedings (OSTI)

The Inventory of Power Plants in the United States provides annual statistics on generating units operated by electric utilities in the US (the 50 States and the District of Columbia). Statistics presented in this report reflect the status of generating units as of January 1, 1998. The publication also provides a 10-year outlook for generating unit additions and generating unit changes. This report is prepared annually by the Energy Information Administration (EIA). Data summarized in this report are useful to a wide audience. This is a report of electric utility data; in cases where summary data or nonconfidential data of nonutilities are presented, it is specifically noted as nonutility data. 19 figs., 36 tabs.

NONE

1998-12-01T23:59:59.000Z

188

Inventory of power plants in the United States 1989. [Contains glossary  

SciTech Connect

This document is prepared annually by the Electric Power Division, Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), US Department of Energy (DOE). The purpose of this publication is to provide year-end statistics about electric generating units in operation and to provide a 10-year outlook of future generating unit additions by electric utilities in the United States (the 50 states and the District of Columbia). Data summarized in this report are useful to a wide audience including Congress, federal and state agencies, the electric utility industry, and the general public. The data presented in this report were assembled and published by the EIA, to fulfill its data collection and dissemination responsibilities as specified in the Federal Energy Administration Act of 1974 (Public Law 93-275) as amended. The report is organized into the following chapters: Summary Statistics; Operable Electric Generating Units; and Projected Electric Generating Unit Additions.

Not Available

1990-09-21T23:59:59.000Z

189

Energy Efficiency and Environmental Impact Analyses of Supermarket Refrigeration Systems  

SciTech Connect

This paper presents energy and life cycle climate performance (LCCP) analyses of a variety of supermarket refrigeration systems to identify designs that exhibit low environmental impact and high energy efficiency. EnergyPlus was used to model refrigeration systems in a variety of climate zones across the United States. The refrigeration systems that were modeled include the traditional multiplex DX system, cascade systems with secondary loops and the transcritical CO2 system. Furthermore, a variety of refrigerants were investigated, including R-32, R-134a, R-404A, R-1234yf, R-717, and R-744. LCCP analysis was used to determine the direct and indirect carbon dioxide emissions resulting from the operation of the various refrigeration systems over their lifetimes. Our analysis revealed that high-efficiency supermarket refrigeration systems may result in up to 44% less energy consumption and 78% reduced carbon dioxide emissions compared to the baseline multiplex DX system. This is an encouraging result for legislators, policy makers and supermarket owners to select low emission, high-efficiency commercial refrigeration system designs for future retrofit and new projects.

Fricke, Brian A [ORNL; Bansal, Pradeep [ORNL; Zha, Shitong [Hillphoenix

2013-01-01T23:59:59.000Z

190

Preliminary selection of refrigerants for dual-circuit and Lorenz refrigerator/freezers  

SciTech Connect

The paper discusses the preliminary selection of refrigerants for dual-circuit and Lorenz refrigerator/freezers (RFs). Since RFs currently use a fully halogenated chlorofluorocarbon (CFC) as a refrigerant and are the most energy-consuming appliances in most households in the U.S., EPA is concerned about not only RFs' effects on stratospheric ozone depletion but also their impact on the greenhouse effect. Reductions in power consumption will slow the increase in carbon dioxide (CO{sub 2}) concentrations in the atmosphere by reducing the utility companies' need for capacity. CO{sub 2} concentrations are believed to be directly related to impacts of the greenhouse effect. For these reasons, EPA believes that finding the most energy-efficient refrigerant(s) and RF design is important when eliminating fully halogenated CFCs. Two new configurations (the dual-circuit and Lorenz RFs) appear to provide energy savings of up to 20% over standard U.S. RF designs.

Bare, J.C.

1990-01-01T23:59:59.000Z

191

Modeling of ECM Controlled Series Fan-powered VAV Terminal Units  

E-Print Network (OSTI)

Semi-empirical models for series fan-powered variable air volume terminal units (FPTUs) were developed based on models of the primary, plenum, fan airflow and the fan power consumption. The experimental setups and test procedures were developed respectively for primary, plenum and fan airflow to test each component of the FPTUs at typical design pressures and airflows. Two sizes of the terminal units from three manufacturers were used in this study. All of the FPTUs were equipped with electronically commutated motors (ECM). Data provided by the models were compared against the data from previous experiments to prove the models’ validity. Regression modeling was performed by using SigmaStat. The model of primary airflow had an R2 above 0.948 for all the terminal units evaluated while the plenum airflow model had an R2 above 0.99. For all the terminal units, the R2 of the fan airflow model was ranged from 0.973 to 0.998. Except for one fan, the fan power consumption model was able to characterize the power performance and had an R2 above 0.986. By combining the airflow and power models, the model for series FPTU was developed. Verification was made to prove the FPTU model’s validity by comparing the measured and predicted data of airflow and power consumption. Correction factors were used in the primary airflow model to compensate for the difference caused by large measurement errors and the system effects. The predicted values were consistent with measurements and no offset was needed in the primary airflow model. Generally, the newly established model was able to describe the airflow performance as well as power consumption of series FPTUs without adding complexity.

Yin, Peng

2010-08-01T23:59:59.000Z

192

Solid Oxide Fuel Cell Auxiliary Power Units for Long-Haul Trucks  

E-Print Network (OSTI)

SOFC Technology R& D Needs Steven Shaffer Chief Engineer ­ Fuel Cell Development DOE Pre) to define system level requirements for a Fuel Cell (SOFC) based Auxiliary Power Unit (APU SOFC X #12;9 DOE Pre-Solicitation Workshop, Golden CO Field Office SOFC Stack Development Key Stack

193

Review of the Current Status of Power Market Reforms in the United States and Europe  

Science Conference Proceedings (OSTI)

The Kyushu Electric Power Company (Kyushu EPCO) requested a survey of the design and performance of electricity markets in six regions in the United States and Europe. This report provides such an evaluation, making recommendations for continued liberalization in the areas of market design and market monitoring.

2002-11-04T23:59:59.000Z

194

Cooperation of heat pump and solar system in the common power unit  

Science Conference Proceedings (OSTI)

The paper explains new possibilities of heat pumps usage in the common power units. The result of applied research is an examination of heat pump and active solar system cooperation eligibility. The aspects of such a cooperation are examined mainly from ... Keywords: combined heating system, heat pump, heating factor, heating factor increase, natural energy, solar system

Mastny Petr

2007-05-01T23:59:59.000Z

195

Land-Use Requirements of Modern Wind Power Plants in the United States  

NLE Websites -- All DOE Office Websites (Extended Search)

4 4 August 2009 Land-Use Requirements of Modern Wind Power Plants in the United States Paul Denholm, Maureen Hand, Maddalena Jackson, and Sean Ong National Renewable Energy Laboratory 1617 Cole Boulevard, Golden, Colorado 80401-3393 303-275-3000 * www.nrel.gov NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Operated by the Alliance for Sustainable Energy, LLC Contract No. DE-AC36-08-GO28308 Technical Report NREL/TP-6A2-45834 August 2009 Land-Use Requirements of Modern Wind Power Plants in the United States Paul Denholm, Maureen Hand, Maddalena Jackson, and Sean Ong Prepared under Task No. WER9.3550 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government.

196

Wind Power Price Trends in the United States: Struggling to Remain Competitive in the Face of Strong Growth  

E-Print Network (OSTI)

Build a Durable Market for Wind Power in the United States”Consult. 2008. “International Wind Energy Development: WorldGlobal Experience Curves for Wind Farms. ” Energy Policy,

Bolinger, Mark A

2009-01-01T23:59:59.000Z

197

Wind Power Price Trends in the United States: Struggling to Remain Competitive in the Face of Strong Growth  

E-Print Network (OSTI)

Curves for Wind Farms. ” Energy Policy, 33: 133-150. Lusey,Curves for Wind Power. ” Energy Policy, 30: 1181- IHS CERA.Wind Power Development in the United States” Energy Policy.

Bolinger, Mark A

2009-01-01T23:59:59.000Z

198

Impact of High Wind Power Penetrations on Hydroelectric Unit Operations in the WWSIS  

NLE Websites -- All DOE Office Websites (Extended Search)

High Wind Power High Wind Power Penetrations on Hydroelectric Unit Operations in the WWSIS Bri-Mathias Hodge, Debra Lew, and Michael Milligan Technical Report NREL/TP-5500-52251 July 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308 The Impact of High Wind Power Penetrations on Hydroelectric Unit Operations in the WWSIS Bri-Mathias Hodge, Debra Lew, and Michael Milligan Prepared under Task No. WE110810 Technical Report NREL/TP-5500-52251 July 2011 NOTICE

199

Green Power Marketing in the United States: A Status Report (2009 Data)  

NLE Websites -- All DOE Office Websites (Extended Search)

Green Power Marketing in the Green Power Marketing in the United States: A Status Report (2009 Data) Lori Bird and Jenny Sumner Technical Report NREL/TP-6A20-49403 September 2010 ERRATA SHEET NREL REPORT/PROJECT NUMBER: TP-6A20-49403 TITLE: Green Power Marketing in the United States: A Status Report (2009 Data) AUTHOR(S): Lori Bird, Jenny Sumner ORIGINAL PUBLICATION DATE: September 2010 DATE OF CORRECTIONS: April 2011 The following corrections were made to this report: On page 36, reference to 2010 vintage WECC wind was removed. In Table 18, data on 2010 vintage WECC wind was removed. NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory

200

Unit commitment with wind power generation: integrating wind forecast uncertainty and stochastic programming.  

DOE Green Energy (OSTI)

We present a computational framework for integrating the state-of-the-art Weather Research and Forecasting (WRF) model in stochastic unit commitment/energy dispatch formulations that account for wind power uncertainty. We first enhance the WRF model with adjoint sensitivity analysis capabilities and a sampling technique implemented in a distributed-memory parallel computing architecture. We use these capabilities through an ensemble approach to model the uncertainty of the forecast errors. The wind power realizations are exploited through a closed-loop stochastic unit commitment/energy dispatch formulation. We discuss computational issues arising in the implementation of the framework. In addition, we validate the framework using real wind speed data obtained from a set of meteorological stations. We also build a simulated power system to demonstrate the developments.

Constantinescu, E. M.; Zavala, V. M.; Rocklin, M.; Lee, S.; Anitescu, M. (Mathematics and Computer Science); (Univ. of Chicago); (New York Univ.)

2009-10-09T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

DOE Closes Investigation into Energy Efficiency of Viking Refrigerator |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Closes Investigation into Energy Efficiency of Viking Closes Investigation into Energy Efficiency of Viking Refrigerator DOE Closes Investigation into Energy Efficiency of Viking Refrigerator November 9, 2010 - 7:30pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Viking Range Corporation's refrigerator-freezer model VCSB542. The Department initiated this investigation in response to allegations that the model failed to meet federal energy efficiency standards. After reviewing data provided by Viking for this model, the Department issued a testing demand on June 16, 2010 and initially tested four units, one of which was defective and replaced by a fifth unit. The test results showed that two Viking units failed the federal energy standard for maximum energy use, while two passed. Because of the wide variation in the

202

DOE Closes Investigation into Energy Efficiency of Viking Refrigerator |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

into Energy Efficiency of Viking into Energy Efficiency of Viking Refrigerator DOE Closes Investigation into Energy Efficiency of Viking Refrigerator November 9, 2010 - 7:30pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Viking Range Corporation's refrigerator-freezer model VCSB542. The Department initiated this investigation in response to allegations that the model failed to meet federal energy efficiency standards. After reviewing data provided by Viking for this model, the Department issued a testing demand on June 16, 2010 and initially tested four units, one of which was defective and replaced by a fifth unit. The test results showed that two Viking units failed the federal energy standard for maximum energy use, while two passed. Because of the wide variation in the

203

Compact acoustic refrigerator  

DOE Patents (OSTI)

This invention is comprised of a compact acoustic refrigeration system that actively cools components, e.g., electrical circuits, in a borehole environment. An acoustic engine includes first thermodynamic elements for generating a standing acoustic wave in a selected medium. An acoustic refrigerator includes second thermodynamic elements located in the standing wave for generating a relatively cold temperature at a first end of the second thermodynamic elements and a relatively hot temperature at a second end of the second thermodynamic elements. A resonator volume cooperates with the first and second thermodynamic elements to support the standing wave. To accommodate the high heat fluxes required for heat transfer to/from the first and second thermodynamic elements, first heat pipes transfer heat from the heat load to the second thermodynamic elements and second heat pipes transfer heat from first and second thermodynamic elements to the borehole environment.

Bennett, G.A.

1991-12-31T23:59:59.000Z

204

Superfluid thermodynamic cycle refrigerator  

DOE Patents (OSTI)

This invention is comprised of a cryogenic refrigerator which cools a heat source by cyclically concentrating and diluting the amount of [sup 3]He in a single phase [sup 3]He/[sup 4]He solution. The [sup 3]He in superfluid [sup 4]He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid [sup 3]He at an initial concentration in superfluid [sup 4]He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of [sup 4]He while restricting passage of [sup 3]He. The [sup 3]He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

Swift, G.W.; Kotsubo, V.Y.

1991-04-02T23:59:59.000Z

205

Compact acoustic refrigerator  

DOE Patents (OSTI)

A compact acoustic refrigeration system actively cools components, e.g., electrical circuits, in a borehole environment. An acoustic engine includes first thermodynamic elements for generating a standing acoustic wave in a selected medium. An acoustic refrigerator includes second thermodynamic elements located in the standing wave for generating a relatively cold temperature at a first end of the second thermodynamic elements and a relatively hot temperature at a second end of the second thermodynamic elements. A resonator volume cooperates with the first and second thermodynamic elements to support the standing wave. To accommodate the high heat fluxes required for heat transfer to/from the first and second thermodynamic elements, first heat pipes transfer heat from the heat load to the second thermodynamic elements and second heat pipes transfer heat from first and second thermodynamic elements to the borehole environment. 18 figs.

Bennett, G.A.

1992-11-24T23:59:59.000Z

206

Superfluid thermodynamic cycle refrigerator  

DOE Patents (OSTI)

A cryogenic refrigerator cools a heat source by cyclically concentrating and diluting the amount of [sup 3]He in a single phase [sup 3]He-[sup 4]He solution. The [sup 3]He in superfluid [sup 4]He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid [sup 3]He at an initial concentration in superfluid [sup 4]He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of [sup 4]He while restricting passage of [sup 3]He. The [sup 3]He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K. 12 figs.

Swift, G.W.; Kotsubo, V.Y.

1992-12-22T23:59:59.000Z

207

Superfluid thermodynamic cycle refrigerator  

DOE Patents (OSTI)

This invention is comprised of a cryogenic refrigerator which cools a heat source by cyclically concentrating and diluting the amount of {sup 3}He in a single phase {sup 3}He/{sup 4}He solution. The {sup 3}He in superfluid {sup 4}He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid {sup 3}He at an initial concentration in superfluid {sup 4}He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of {sup 4}He while restricting passage of {sup 3}He. The {sup 3}He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

Swift, G.W.; Kotsubo, V.Y.

1991-04-02T23:59:59.000Z

208

Compact acoustic refrigerator  

DOE Patents (OSTI)

A compact acoustic refrigeration system actively cools components, e.g., electrical circuits (22), in a borehole environment. An acoustic engine (12, 14) includes first thermodynamic elements (12) for generating a standing acoustic wave in a selected medium. An acoustic refrigerator (16, 26, 28) includes second thermodynamic elements (16) located in the standing wave for generating a relatively cold temperature at a first end of the second thermodynamic elements (16) and a relatively hot temperature at a second end of the second thermodynamic elements (16). A resonator volume (18) cooperates with the first and second thermodynamic elements (12, 16) to support the standing wave. To accommodate the high heat fluxes required for heat transfer to/from the first and second thermodynamic elements (12, 16), first heat pipes (24, 26) transfer heat from the heat load (22) to the second thermodynamic elements (16) and second heat pipes (28, 32) transfer heat from first and second thermodynamic elements (12, 16) to the borehole environment.

Bennett, Gloria A. (Los Alamos, NM)

1992-01-01T23:59:59.000Z

209

Superfluid thermodynamic cycle refrigerator  

DOE Patents (OSTI)

A cryogenic refrigerator cools a heat source by cyclically concentrating and diluting the amount of .sup.3 He in a single phase .sup.3 He-.sup.4 He solution. The .sup.3 He in superfluid .sup.4 He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid .sup.3 He at an initial concentration in superfluid .sup.4 He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of .sup.4 He while restricting passage of .sup.3 He. The .sup.3 He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

Swift, Gregory W. (Santa Fe, NM); Kotsubo, Vincent Y. (La Canada, CA)

1992-01-01T23:59:59.000Z

210

Multilayer Thermionic Refrigeration  

DOE Green Energy (OSTI)

A review is presented of our program to construct an efficient solid state refrigerator based on thermionic emission of electrons over periodic barriers in the solid. The experimental program is to construct a simple device with one barrier layer using a three layers: metal-semiconductor-metal. The theoretical program is doing calculations to determine: (i) the optimal layer thickness, and (ii) the thermal conductivity.

Mahan, G.D.

1999-08-30T23:59:59.000Z

211

AMERICAN ELECTRIC POWER'S CONESVILLE POWER PLANT UNIT NO.5 CO2 CAPTURE RETROFIT STUDY  

SciTech Connect

ALSTOM Power Inc.'s Power Plant Laboratories (ALSTOM) has teamed with American Electric Power (AEP), ABB Lummus Global Inc. (ABB), the US Department of Energy National Energy Technology Laboratory (DOE NETL), and the Ohio Coal Development Office (OCDO) to conduct a comprehensive study evaluating the technical feasibility and economics of alternate CO{sub 2} capture and sequestration technologies applied to an existing US coal-fired electric generation power plant. The motivation for this study was to provide input to potential US electric utility actions concerning GHG emissions reduction. If the US decides to reduce CO{sub 2} emissions, action would need to be taken to address existing power plants. Although fuel switching from coal to natural gas may be one scenario, it will not necessarily be a sufficient measure and some form of CO{sub 2} capture for use or disposal may also be required. The output of this CO{sub 2} capture study will enhance the public's understanding of control options and influence decisions and actions by government, regulators, and power plant owners in considering the costs of reducing greenhouse gas CO{sub 2} emissions. The total work breakdown structure is encompassed within three major reports, namely: (1) Literature Survey, (2) AEP's Conesville Unit No.5 Retrofit Study, and (3) Bench-Scale Testing and CFD Evaluation. The report on the literature survey results was issued earlier by Bozzuto, et al. (2000). Reports entitled ''AEP's Conesville Unit No.5 Retrofit Study'' and ''Bench-Scale Testing and CFD Evaluation'' are provided as companion volumes, denoted Volumes I and II, respectively, of the final report. The work performed, results obtained, and conclusions and recommendations derived therefrom are summarized.

Carl R. Bozzuto; Nsakala ya Nsakala; Gregory N. Liljedahl; Mark Palkes; John L. Marion

2001-06-30T23:59:59.000Z

212

Green Power Marketing in the United States: A Status Report (2008 Data)  

Science Conference Proceedings (OSTI)

Voluntary consumer decisions to buy electricity supplied from renewable energy sources represent a powerful market support mechanism for renewable energy development. In the early 1990s, a small number of U.S. utilities began offering 'green power' options to their customers. Since then, these products have become more prevalent, both from traditional utilities and from renewable energy marketers operating in states that have introduced competition into their retail electricity markets or offering renewable energy certificates (RECs) online. Today, more than half of all U.S. electricity customers have an option to purchase some type of green power product directly from a retail electricity provider, while all consumers have the option to purchase RECs. This report documents green power marketing activities and trends in the United States including utility green pricing programs offered in regulated electricity markets; green power marketing activity in competitive electricity markets, as well as green power sold to voluntary purchasers in the form of RECs; and renewable energy sold as greenhouse gas offsets in the United States. These sections are followed by a discussion of key market trends and issues. The final section offers conclusions and observations.

Bird, L.; Kreycik, C.; Friedman, B.

2009-09-01T23:59:59.000Z

213

Data processing unit and power system for the LANL REM instrument package. Final report  

SciTech Connect

The NEPSTP spacecraft needs highly reliable instrumentation to measure the nuclear reactor health and performance. These reactor measurements are essential for initial on-orbit phase operations and documentation of performance over time. Los Alamos National Laboratory (LANL), under the guidance of W. C. Feldman, principal investigator, has designed the Radiation Environment Monitoring (REM) package to meet these needs. The instrumentation package contains two neutron detectors, one gamma-ray detector, a data processing unit, and an instrument power system. The REM package is an integration of quick turn-around, state of the practice technology for detectors, data processors, and power systems. A significant portion of REM consists of subsystems with flight history. Southwest Research Institute (SwRI) has been tasked by LANL to design support electronics, including the Data Processing Unit (DPU) and Power System for REM. The goal for this project is to use technologies from current programs to speed up and simplify the design process. To meet these design goals, the authors use an open architecture VME bus for the DPU and derivatives of CASSINI power supplies for the instrument power system. To simplify integration and test activities, they incorporate a proven software development strategy and tool kits from outside vendors. The objective of this report is to illustrate easily incorporated system level designs for the DPU, power system and ground support electronics (GSE) in support of the important NEPSTP program.

Lockhart, W. [Southwest Research Inst., San Antonio, TX (United States). Instrumentation and Space Research Div.

1994-03-01T23:59:59.000Z

214

Magnetic Refrigeration - Programmaster.org  

Science Conference Proceedings (OSTI)

Aug 6, 2013 ... Magnetic Refrigeration a 21st Century Highly Efficient and Green Cooling .... In order to advance their incorporation in prototypes and industrial ...

215

A computational framework for uncertainty quantification and stochastic optimization in unit commitment with wind power generation.  

Science Conference Proceedings (OSTI)

We present a computational framework for integrating a state-of-the-art numerical weather prediction (NWP) model in stochastic unit commitment/economic dispatch formulations that account for wind power uncertainty. We first enhance the NWP model with an ensemble-based uncertainty quantification strategy implemented in a distributed-memory parallel computing architecture. We discuss computational issues arising in the implementation of the framework and validate the model using real wind-speed data obtained from a set of meteorological stations. We build a simulated power system to demonstrate the developments.

Constantinescu, E. M; Zavala, V. M.; Rocklin, M.; Lee, S.; Anitescu, M. (Mathematics and Computer Science); (Univ. of Chicago); (New York Univ.)

2011-02-01T23:59:59.000Z

216

Social Acceptance of Wind Power in the United States: Evaluating Stakeholder Perspectives (Poster)  

DOE Green Energy (OSTI)

As the wind industry strives to achieve 20% wind energy by 2030, maintaining high levels of social acceptance for wind energy will become increasingly important. Wind Powering America is currently researching stakeholder perspectives in the U.S. market and reviewing findings from wind energy projects around the world to better understand social acceptance barriers. Results from European studies show that acceptance varies widely depending on local community values. A preliminary survey shows similar results in the United States. Further research will be conducted to refine our understanding of key social acceptance barriers and evaluate the best ways to mitigate negative perspectives on wind power.

Tegen, S.; Lantz, E.

2009-05-01T23:59:59.000Z

217

Commercial Refrigeration Equipment | Open Energy Information  

Open Energy Info (EERE)

Refrigeration Equipment Jump to: navigation, search TODO: Add description List of Commercial Refrigeration Equipment Incentives Retrieved from "http:en.openei.orgw...

218

Development of Refrigerant Change Indicator and Dirty Air Filter Sensor  

Science Conference Proceedings (OSTI)

The most common problems affecting residential and light commercial heating, ventilation, and air-conditioning (HVAC) systems are slow refrigerant leaks and dirty air filters. Equipment users are usually not aware of a problem until most of the refrigerant has escaped or the air filter is clogged with dirt. While a dirty air filter can be detected with a technology based on the air pressure differential across the filter, such as a ''whistling'' indicator, it is not easy to incorporate this technology into existing HVAC diagnostic equipment. Oak Ridge National Laboratory is developing a low-cost, nonintrusive refrigerant charge indicator and dirty air filter detection sensor. The sensors, based on temperature measurements, will be inexpensive and easy to incorporate into existing heat pumps and air conditioners. The refrigerant charge indicator is based on the fact that when refrigerant starts to leak, the evaporator coil temperature starts to drop and the level of liquid subcooling drops. When the coil temperature or liquid subcooling drops below a preset reading, a signal, such as a yellow warning light, can be activated to warn the equipment user that the system is undercharged. A further drop of coil temperature or liquid subcooling below another preset reading would trigger a second warning signal, such as a red warning light, to warn the equipment user that the unit now detects a leak and immediate action should be taken. The warning light cannot be turned off until it is re-set by a refrigeration repairman. To detect clogged air filters, two additional temperature sensors can be applied, one each across the evaporator. When the air filter is accumulating buildup, the temperature differential across the evaporator will increase because of the reduced airflow. When the temperature differential reaches a pre-set reading, a signal will be sent to the equipment user that the air filter needs to be changed. A traditional refrigerant charge indicator requires intrusion into the system to measure the refrigerant high-side and low-side pressures. Once the pressures are known, based on the equipment's refrigerant charging chart? or in most cases, based on the technician's experience? the refrigerant charging status is determined. However, there is a catch: by the time a refrigeration technician is called, most of the refrigerant has already escaped into the atmosphere. The new technology provides a real-time warning so that when, say, 20% of the refrigerant has leaked, the equipment users will be warned, even though the equipment is still functioning properly at rated capacity. Temperature sensors are becoming very accurate and very low in cost, compared with pressure sensors. Using temperature sensors to detect refrigerant charge status is inherently nonintrusive, inexpensive, and accurate. With the addition of two temperature sensors for detecting dirty air filters, the capability of the diagnostic equipment is further enhanced with very little added cost. This report provides laboratory test data on the change of indoor coil refrigerant temperature and subcooling as a function of refrigerant charge for a 2-ton split heat pump system. The data can be used in designing the indicators for refrigerant loss and dirty air filter sensors.

Mei, V.

2003-06-24T23:59:59.000Z

219

Performance bound for quantum absorption refrigerators  

E-Print Network (OSTI)

An implementation of quantum absorption chillers with three qubits has been recently proposed, that is ideally able to reach the Carnot performance regime. Here we study the working efficiency of such self-contained refrigerators, adopting a consistent treatment of dissipation effects. We demonstrate that the coefficient of performance at maximum cooling power is upper bounded by 3/4 of the Carnot performance. The result is independent of the details of the system and the equilibrium temperatures of the external baths. We provide design prescriptions that saturate the bound in the limit of a large difference between the operating temperatures. Our study suggests that delocalized dissipation, which must be taken into account for a proper modelling of the machine-baths interaction, is a fundamental source of irreversibility which prevents the refrigerator from approaching the Carnot performance arbitrarily closely in practice. The potential role of quantum correlations in the operation of these machines is also investigated.

Luis A. Correa; José P. Palao; Gerardo Adesso; Daniel Alonso

2012-12-18T23:59:59.000Z

220

SCREW COMPRESSOR CHARACTERISTICS FOR HELIUM REFRIGERATION SYSTEMS  

SciTech Connect

The oil injected screw compressors have practically replaced all other types of compressors in modern helium refrigeration systems due to their large displacement capacity, minimal vibration, reliability and capability of handling helium's high heat of compression.At the present state of compressor system designs for helium systems, typically two-thirds of the lost input power is due to the compression system. Therefore it is important to understand the isothermal and volumetric efficiencies of these machines to help properly design these compression systems to match the refrigeration process. This presentation summarizes separate tests that have been conducted on Sullair compressors at the Superconducting Super-Collider Laboratory (SSCL) in 1993, Howden compressors at Jefferson Lab (JLab) in 2006 and Howden compressors at the Spallation Neutron Source (SNS) in 2006. This work is part of an ongoing study at JLab to understand the theoretical basis for these efficiencies and their loss

Ganni, Venkatarao; Knudsen, Peter; Creel, Jonathan; Arenius, Dana; Casagrande, Fabio; Howell, Matt

2008-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Green Power Marketing in the United States: A Status Report (Ninth Edition)  

NLE Websites -- All DOE Office Websites (Extended Search)

of of Energy Office of Energy Efficiency & Renewable Energy National Renewable Energy Laboratory Innovation for Our Energy Future Green Power Marketing in the United States: A Status Report (Ninth Edition) Lori Bird and Blair Swezey Technical Report NREL/TP-640-40904 November 2006 NREL is operated by Midwest Research Institute ● Battelle Contract No. DE-AC36-99-GO10337 Green Power Marketing in the United States: A Status Report (Ninth Edition) Lori Bird and Blair Swezey Prepared under Task No. ASG6.1003 Technical Report NREL/TP-640-40904 November 2006 National Renewable Energy Laboratory 1617 Cole Boulevard, Golden, Colorado 80401-3393 303-275-3000 * www.nrel.gov Operated for the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy

222

Making european-style community wind power development work in theUnited States  

DOE Green Energy (OSTI)

Once primarily a European phenomenon, community wind power development--defined here as one or more locally owned, utility-scale wind turbines interconnected on either the customer or utility side of the meter--is gaining a foothold in an increasing number of states throughout the United States. This article describes the various policies and incentives that Minnesota, Wisconsin, Iowa, and Massachusetts are using to support community wind power development, and how state and federal support influences the types of projects and ownership structures that are being developed. Experience in these states demonstrates that, with an array of incentives and creative financing schemes targeted at community-scale projects, there are opportunities to make community wind work in the United States.

Bolinger, Mark A.

2004-04-26T23:59:59.000Z

223

Chilled Ammonia Process Development Unit at We Energies Pleasant Prairie Power Plant  

Science Conference Proceedings (OSTI)

Alstom Power, Inc. (Alstom) has developed a patented process technology referred to as the chilled ammonia process (CAP) for the capture and concentration of carbon dioxide from combustion flue gas. The technology involves the use of a chilled, concentrated ammonia solution to chemically bind the carbon dioxide, followed by a thermal decomposition step to liberate the carbon dioxide for collection and further use. This report documents results from the process development unit (PDU) testing of the CAP at...

2011-01-24T23:59:59.000Z

224

Green Power Marketing in the United States: A Status Report ; Fifth Edition  

NLE Websites -- All DOE Office Websites (Extended Search)

in the in the United States: A Status Report Fifth Edition August 2000 * NREL/TP-620-28738 Blair Swezey and Lori Bird National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401-3393 NREL is a U.S. Department of Energy Laboratory Operated by Midwest Research Institute * * * * Battelle * * * * Bechtel Contract No. DE-AC36-99-GO10337 National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401-3393 NREL is a U.S. Department of Energy Laboratory Operated by Midwest Research Institute * * * * Battelle * * * * Bechtel Contract No. DE-AC36-99-GO10337 August 2000 * NREL/TP-620-28738 Green Power Marketing in the United States: A Status Report Fifth Edition Blair Swezey and Lori Bird Prepared under Task No. AS65.3010 NOTICE This report was prepared as an account of work sponsored by an agency of the United States

225

Green Power Marketing in the United States: A Status Report (Eighth Edition)  

SciTech Connect

Voluntary consumer decisions to purchase electricity supplied by renewable energy sources represent a powerful market support mechanism for renewable energy development. Beginning in the early 1990s, a small number of U.S. utilities began offering "green power" options to their customers. Since then, these products have become more prevalent, both from utilities and in states that have introduced competition into their retail electricity markets. Today, more than 50% of all U.S. consumers have an option to purchase some type of green power product from a retail electricity provider. This report provides an overview of green power marketing activity in the United States. The first section provides an overview of green power markets, consumer response, and recent industry trends. The second section provides brief descriptions of utility green pricing programs. The third section describes companies that actively market green power in competitive markets and those that market renewable energy certificates nationally or regionally. The final section provides information on a select number of large, nonresidential green power purchasers, including businesses, universities, and government agencies.

Bird, L.; Swezey, B.

2005-10-01T23:59:59.000Z

226

Improving the energy efficiency of refrigerators in India  

Science Conference Proceedings (OSTI)

Five state-of-the-art, production refrigerators from different manufacturers in India were subjected to a variety of appliance rating and performance evaluation test procedures in an engineering laboratory. Cabinet heat loss, compressor calorimeter, high-ambient pull-down, and closed-door energy consumption tests were performed on each unit to assess the current status of commercially available Indian refrigerators and refrigerator component efficiencies. Daily energy consumption tests were performed at nominal line voltages and at 85% and 115% of nominal voltage to assess the effect of grid voltage variations. These test results were also used to indicate opportunities for effective improvements in energy efficiency. A widely distributed ``generic`` computer model capable of simulating single-door refrigerators with a small interior freezer section was used to estimate cabinet heat loss rates and closed door energy consumption values from basic cabinet and refrigeration circuit inputs. This work helped verify the model`s accuracy and potential value as a tool for evaluating the energy impact of proposed design options. Significant differences ranging from 30 to 90% were seen in the measured performance criterion for these ``comparable`` refrigerators suggesting opportunities for improvements in individual product designs. Modeled cabinet heat loadings differed from experimentally extrapolated values in a range from 2--29%, and daily energy consumption values estimated by the model differed from laboratory data by as little as 3% or as much as 25%, which indicates that refinement of the model may be needed for this single-door refrigerator type. Additional comparisons of experimentally measured performance criteria such as % compressor run times and compressor cycling rates to modeled results are given. The computer model is used to evaluate the energy saving impact of several modest changes to the basic Indian refrigerator design.

Sand, J.R.; Vineyard, E.A. [Oak Ridge National Lab., TN (United States); Bohman, R.H. [Consulting Engineer, Cedar Rapids, IA (United States)

1995-04-01T23:59:59.000Z

227

Operation of the Tevatron satellite refrigerators for. 75- and 2. 0-kilometer-long magnet strings  

SciTech Connect

The Tevatron magnets at Fermilab are cooled by a hybrid system which consists of a 5000 liters/hr central helium liquefier coupled with a small-diameter liquid transfer line connecting twenty-four satellite refrigerators. The transfer line supplies liquid helium for both the refrigerators and the magnet lead flow as well as liquid nitrogen for the magnet shields. The satellites act as amplifiers with a gain of twelve by using the enthalpy of the helium supplied by the central liquefier as liquid and converting it to 4.5-K refrigeration and then returning it as 300-K gas. This arrangement combines the advantages of a single central facility with those of individual stand-alone units stationed around the ring. The central liquefier has the high efficiency associated with large components but its requirements for distribution of both cryogenic liquids and electric power to the service buildings is reduced. The six compressor buildings supply 20 atm helium to the twenty-four refrigerators through a discharge header located on the berm and a suction header located in the tunnel. The compressor buildings each have four-two stage 58 g/sec screw compressors; each of these has its own oil removal system. The inventory in the ring is controlled at the first compressor building through a cross-connect line to the central liquefier. The suction header is also used as the cooldown line as well as for quench relief. A third header located in the tunnel is the nitrogen collection and relief header.

Rode, C.H.; Andrews, R.A.; Ferry, R.; Gannon, J.; Makara, J.; Martin, M.; Misek, J.; Peterson, T.; Theilacker, J.

1983-08-01T23:59:59.000Z

228

15 KJ FLASH LAMP, POWER CONDITIONING UNIT DESIGNED FOR SAFTY, RELIABILITY & MANUFACTURABILITY*  

SciTech Connect

A 15kJoule, Flash Lamp Power Conditioning Unit has been successfully designed, developed, and deployed in the National Ignition Facility (NIF) Preamplifier Modules (PAM). The primary design philosophy of this power conditioning unit (PCU) is safety, reliability, and manufacturability. Cost reduction over commercially equivalent systems was also achieved through an easily manufactured packaging design optimized to meet NIF requirements. While still maintaining low cost, the PCU design includes a robust control system, fault diagnostic system, and safety features. The pulsed power design includes 6 PFN modules, each including a dual series injection trigger transformer, that drive a total of 12 flash lamp loads. The lamps are individually triggered via a 20kV pulse produced by a 1kV, MCT switched capacitive discharge unit on the primary side of the trigger transformer. The remote control interface includes an embedded controller that captures flash lamp current wave forms and fault status for each shot. The embedded controller provides the flexibility of remotely adjusting both the main drive voltage from 1.6 to 2.5 kV and the trigger voltage from 0 to 20 kV.

James, G; Merritt, B; Dreifuerst, G; Strickland, S

2007-08-07T23:59:59.000Z

229

Technology data characterizing refrigeration in commercial buildings: Application to end-use forecasting with COMMEND 4.0  

SciTech Connect

In the United States, energy consumption is increasing most rapidly in the commercial sector. Consequently, the commercial sector is becoming an increasingly important target for state and federal energy policies and also for utility-sponsored demand side management (DSM) programs. The rapid growth in commercial-sector energy consumption also makes it important for analysts working on energy policy and DSM issues to have access to energy end-use forecasting models that include more detailed representations of energy-using technologies in the commercial sector. These new forecasting models disaggregate energy consumption not only by fuel type, end use, and building type, but also by specific technology. The disaggregation of the refrigeration end use in terms of specific technologies, however, is complicated by several factors. First, the number of configurations of refrigeration cases and systems is quite large. Also, energy use is a complex function of the refrigeration-case properties and the refrigeration-system properties. The Electric Power Research Institute`s (EPRI`s) Commercial End-Use Planning System (COMMEND 4.0) and the associated data development presented in this report attempt to address the above complications and create a consistent forecasting framework. Expanding end-use forecasting models so that they address individual technology options requires characterization of the present floorstock in terms of service requirements, energy technologies used, and cost-efficiency attributes of the energy technologies that consumers may choose for new buildings and retrofits. This report describes the process by which we collected refrigeration technology data. The data were generated for COMMEND 4.0 but are also generally applicable to other end-use forecasting frameworks for the commercial sector.

Sezgen, O.; Koomey, J.G.

1995-12-01T23:59:59.000Z

230

Geothermal power plants of the United States: a technical survey of existing and planned installations  

DOE Green Energy (OSTI)

The development of geothermal energy as a source of electric power in the United States is reviewed. A thorough description is given of The Geysers geothermal power project in northern California. The recent efforts to exploit the hot-water resources of the Mexicali-Imperial Rift Valley are described. Details are given concerning the geology of the several sites now being used and for those at which power plants will soon be built. Attention is paid to the technical particulars of all existing plants, including wells, gathering systems, energy conversion devices, materials, environmental impacts, economics and operating characteristics. Specifically, plants which either exist or are planned for the following locations are covered: The Geysers, CA; East Mesa, CA; Heber, CA; Roosevelt Hot Springs, UT; Valles Caldera, NM; Salton Sea, CA; Westmorland, CA; Brawley, CA; Desert Peak, NV; and Raft River, ID. The growth of installed geothermal electric generating capacity is traced from the beginning in 1960 and is projected to 1984.

DiPippo, R.

1978-04-01T23:59:59.000Z

231

Green Power Marketing in the United States: A Status Report (Ninth Edition)  

SciTech Connect

Voluntary consumer decisions to purchase electricity supplied by renewable energy sources represent a powerful market support mechanism for renewable energy development. Beginning in the early 1990s, a small number of U.S. utilities began offering ''green power'' options to their customers. Since then, these products have become more prevalent, both from traditional utilities and from marketers operating in states that have introduced competition into their retail electricity markets. Today, more than half of all U.S. consumers have an option to purchase some type of green power product from a retail electricity provider. Currently, more than 600 utilities, or about 20% of utilities nationally, offer green power programs to customers. These programs allow customers to purchase some portion of their power supply as renewable energy--almost always at a higher price--or to contribute funds for the utility to invest in renewable energy development. The term ''green pricing'' is typically used to refer to these utility programs offered in regulated or noncompetitive electricity markets. This report documents green power marketing activities and trends in the United States.

Bird, L.; Swezey, B.

2006-11-01T23:59:59.000Z

232

Green Power Marketing in the United States: A Status Report (Ninth Edition)  

SciTech Connect

Voluntary consumer decisions to purchase electricity supplied by renewable energy sources represent a powerful market support mechanism for renewable energy development. Beginning in the early 1990s, a small number of U.S. utilities began offering ''green power'' options to their customers. Since then, these products have become more prevalent, both from traditional utilities and from marketers operating in states that have introduced competition into their retail electricity markets. Today, more than half of all U.S. consumers have an option to purchase some type of green power product from a retail electricity provider. Currently, more than 600 utilities, or about 20% of utilities nationally, offer green power programs to customers. These programs allow customers to purchase some portion of their power supply as renewable energy--almost always at a higher price--or to contribute funds for the utility to invest in renewable energy development. The term ''green pricing'' is typically used to refer to these utility programs offered in regulated or noncompetitive electricity markets. This report documents green power marketing activities and trends in the United States.

Bird, L.; Swezey, B.

2006-11-01T23:59:59.000Z

233

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve  

E-Print Network (OSTI)

The effect of the improper charging on steady state and cyclic performance (capacity, EER, power consumption, SEER, and coefficient of degradation) of a residential air conditioner which utilized a thermal expansion valve was investigated. This study was the continuation of ESL/CON/88-1 performed by Mohsen Farzad and Dennis O'Neal. A fully charged condition was established as a base case. The full charge was obtained by charging the unit to the subcooling specified by the manufacturer for a specific indoor and outdoor temperatures. Once the full charge was determined, the unit was subjected to 40%, 30%, 20%, 15%, 10%, and 5% undercharging and 5%, 10%, 15%, and 20% overcharging of refrigerant by mass. The fully charged tests were compared to those for under and overcharging. The performance of the unit was evaluated as a function of charge as well as at four outdoor room temperatures (82°F, 90°F, 95°F, and 100°F). As the outdoor temperature increased, the total capacity and EER dropped. The maximum total capacity, EER, and SEER were found at 10% undercharging (12 6 oz). The capacity and efficiency (EER and SEER) of the unit were found to be less sensitive to under/overcharging than the unit with a capillary tube expansion previously studied. Other data such as refrigerant flow rate, sensible heat ratio, superheat and subcooling were also presented.

Farzad, M.; O'Neal, D. L.

1989-01-01T23:59:59.000Z

234

Demand Response Opportunities in Industrial Refrigerated Warehouses in  

NLE Websites -- All DOE Office Websites (Extended Search)

Response Opportunities in Industrial Refrigerated Warehouses in Response Opportunities in Industrial Refrigerated Warehouses in California Title Demand Response Opportunities in Industrial Refrigerated Warehouses in California Publication Type Conference Paper LBNL Report Number LBNL-4837E Year of Publication 2011 Authors Goli, Sasank, Aimee T. McKane, and Daniel Olsen Conference Name 2011 ACEEE Summer Study on Energy Efficiency in Industry Date Published 08/2011 Conference Location Niagara Falls, NY Keywords market sectors, openadr, refrigerated warehouses Abstract Industrial refrigerated warehouses that implemented energy efficiency measures and have centralized control systems can be excellent candidates for Automated Demand Response (Auto-DR) due to equipment synergies, and receptivity of facility managers to strategies that control energy costs without disrupting facility operations. Auto-DR utilizes OpenADR protocol for continuous and open communication signals over internet, allowing facilities to automate their Demand Response (DR). Refrigerated warehouses were selected for research because: They have significant power demand especially during utility peak periods; most processes are not sensitive to short-term (2-4 hours) lower power and DR activities are often not disruptive to facility operations; the number of processes is limited and well understood; and past experience with some DR strategies successful in commercial buildings may apply to refrigerated warehouses. This paper presents an overview of the potential for load sheds and shifts from baseline electricity use in response to DR events, along with physical configurations and operating characteristics of refrigerated warehouses. Analysis of data from two case studies and nine facilities in Pacific Gas and Electric territory, confirmed the DR abilities inherent to refrigerated warehouses but showed significant variation across facilities. Further, while load from California's refrigerated warehouses in 2008 was 360 MW with estimated DR potential of 45-90 MW, actual achieved was much less due to low participation. Efforts to overcome barriers to increased participation may include, improved marketing and recruitment of potential DR sites, better alignment and emphasis on financial benefits of participation, and use of Auto-DR to increase consistency of participation.

235

Reducing water freshwater consumption at coal-fired power plants : approaches used outside the United States.  

Science Conference Proceedings (OSTI)

Coal-fired power plants consume huge quantities of water, and in some water-stressed areas, power plants compete with other users for limited supplies. Extensive use of coal to generate electricity is projected to continue for many years. Faced with increasing power demands and questionable future supplies, industries and governments are seeking ways to reduce freshwater consumption at coal-fired power plants. As the United States investigates various freshwater savings approaches (e.g., the use of alternative water sources), other countries are also researching and implementing approaches to address similar - and in many cases, more challenging - water supply and demand issues. Information about these non-U.S. approaches can be used to help direct near- and mid-term water-consumption research and development (R&D) activities in the United States. This report summarizes the research, development, and deployment (RD&D) status of several approaches used for reducing freshwater consumption by coal-fired power plants in other countries, many of which could be applied, or applied more aggressively, at coal-fired power plants in the United States. Information contained in this report is derived from literature and Internet searches, in some cases supplemented by communication with the researchers, authors, or equipment providers. Because there are few technical, peer-reviewed articles on this topic, much of the information in this report comes from the trade press and other non-peer-reviewed references. Reducing freshwater consumption at coal-fired power plants can occur directly or indirectly. Direct approaches are aimed specifically at reducing water consumption, and they include dry cooling, dry bottom ash handling, low-water-consuming emissions-control technologies, water metering and monitoring, reclaiming water from in-plant operations (e.g., recovery of cooling tower water for boiler makeup water, reclaiming water from flue gas desulfurization [FGD] systems), and desalination. Some of the direct approaches, such as dry air cooling, desalination, and recovery of cooling tower water for boiler makeup water, are costly and are deployed primarily in countries with severe water shortages, such as China, Australia, and South Africa. Table 1 shows drivers and approaches for reducing freshwater consumption in several countries outside the United States. Indirect approaches reduce water consumption while meeting other objectives, such as improving plant efficiency. Plants with higher efficiencies use less energy to produce electricity, and because the greater the energy production, the greater the cooling water needs, increased efficiency will help reduce water consumption. Approaches for improving efficiency (and for indirectly reducing water consumption) include increasing the operating steam parameters (temperature and pressure); using more efficient coal-fired technologies such as cogeneration, IGCC, and direct firing of gas turbines with coal; replacing or retrofitting existing inefficient plants to make them more efficient; installing high-performance monitoring and process controls; and coal drying. The motivations for increasing power plant efficiency outside the United States (and indirectly reducing water consumption) include the following: (1) countries that agreed to reduce carbon emissions (by ratifying the Kyoto protocol) find that one of the most effective ways to do so is to improve plant efficiency; (2) countries that import fuel (e.g., Japan) need highly efficient plants to compensate for higher coal costs; (3) countries with particularly large and growing energy demands, such as China and India, need large, efficient plants; (4) countries with large supplies of low-rank coals, such as Germany, need efficient processes to use such low-energy coals. Some countries have policies that encourage or mandate reduced water consumption - either directly or indirectly. For example, the European Union encourages increased efficiency through its cogeneration directive, which requires member states to assess their

Elcock, D. (Environmental Science Division)

2011-05-09T23:59:59.000Z

236

Reducing water freshwater consumption at coal-fired power plants : approaches used outside the United States.  

SciTech Connect

Coal-fired power plants consume huge quantities of water, and in some water-stressed areas, power plants compete with other users for limited supplies. Extensive use of coal to generate electricity is projected to continue for many years. Faced with increasing power demands and questionable future supplies, industries and governments are seeking ways to reduce freshwater consumption at coal-fired power plants. As the United States investigates various freshwater savings approaches (e.g., the use of alternative water sources), other countries are also researching and implementing approaches to address similar - and in many cases, more challenging - water supply and demand issues. Information about these non-U.S. approaches can be used to help direct near- and mid-term water-consumption research and development (R&D) activities in the United States. This report summarizes the research, development, and deployment (RD&D) status of several approaches used for reducing freshwater consumption by coal-fired power plants in other countries, many of which could be applied, or applied more aggressively, at coal-fired power plants in the United States. Information contained in this report is derived from literature and Internet searches, in some cases supplemented by communication with the researchers, authors, or equipment providers. Because there are few technical, peer-reviewed articles on this topic, much of the information in this report comes from the trade press and other non-peer-reviewed references. Reducing freshwater consumption at coal-fired power plants can occur directly or indirectly. Direct approaches are aimed specifically at reducing water consumption, and they include dry cooling, dry bottom ash handling, low-water-consuming emissions-control technologies, water metering and monitoring, reclaiming water from in-plant operations (e.g., recovery of cooling tower water for boiler makeup water, reclaiming water from flue gas desulfurization [FGD] systems), and desalination. Some of the direct approaches, such as dry air cooling, desalination, and recovery of cooling tower water for boiler makeup water, are costly and are deployed primarily in countries with severe water shortages, such as China, Australia, and South Africa. Table 1 shows drivers and approaches for reducing freshwater consumption in several countries outside the United States. Indirect approaches reduce water consumption while meeting other objectives, such as improving plant efficiency. Plants with higher efficiencies use less energy to produce electricity, and because the greater the energy production, the greater the cooling water needs, increased efficiency will help reduce water consumption. Approaches for improving efficiency (and for indirectly reducing water consumption) include increasing the operating steam parameters (temperature and pressure); using more efficient coal-fired technologies such as cogeneration, IGCC, and direct firing of gas turbines with coal; replacing or retrofitting existing inefficient plants to make them more efficient; installing high-performance monitoring and process controls; and coal drying. The motivations for increasing power plant efficiency outside the United States (and indirectly reducing water consumption) include the following: (1) countries that agreed to reduce carbon emissions (by ratifying the Kyoto protocol) find that one of the most effective ways to do so is to improve plant efficiency; (2) countries that import fuel (e.g., Japan) need highly efficient plants to compensate for higher coal costs; (3) countries with particularly large and growing energy demands, such as China and India, need large, efficient plants; (4) countries with large supplies of low-rank coals, such as Germany, need efficient processes to use such low-energy coals. Some countries have policies that encourage or mandate reduced water consumption - either directly or indirectly. For example, the European Union encourages increased efficiency through its cogeneration directive, which requires member states to assess their

Elcock, D. (Environmental Science Division)

2011-05-09T23:59:59.000Z

237

Indoor unit for electric heat pump  

DOE Patents (OSTI)

An indoor unit for an electric heat pump is provided in modular form including a refrigeration module, an air mover module, and a resistance heat package module, the refrigeration module including all of the indoor refrigerant circuit components including the compressor in a space adjacent the heat exchanger, the modules being adapted to be connected to air flow communication in several different ways as shown to accommodate placement of the unit in various orientations. 9 figs.

Draper, R.; Lackey, R.S.; Fagan, T.J. Jr.; Veyo, S.E.; Humphrey, J.R.

1984-05-22T23:59:59.000Z

238

Job Creation Due to Nuclear Power Resurgence in The United States  

Science Conference Proceedings (OSTI)

The recent revival of global interest in the next generation of nuclear power reactors is causing a reexamination of the role of nuclear power in the United States. This renewed interest has led to questions regarding the capability and capacity of current U.S. industries to support a renewal of nuclear power plant deployment. Key among the many questions currently being asked is what potential exists for the creation of new jobs as a result of developing and operating these new plants? Idaho National Laboratory and Bechtel Power Corporation collaborated to perform a Department of Energy-sponsored study that evaluated the potential for job creation in the U.S. should these new next generation nuclear power plants be built. The study focused primarily on providing an initial estimate of the numbers of new manufacturing jobs that could be created, including those that could be repatriated from overseas, resulting from the construction of these new reactors. In addition to the growth in the manufacturing sector, the study attempted to estimate the potential increase in construction trades necessary to accomplish the new construction.

C. R. Kenley; R. D. Klingler; C. M. Plowman; R. Soto; R. J. Turk; R. L. Baker; S. A. Close; V. L. McDonnell; S. W. Paul; L. R. Rabideau; S. S. Rao; B. P. Reilly

2009-11-01T23:59:59.000Z

239

Use of GTE-65 gas turbine power units in the thermal configuration of steam-gas systems for the refitting of operating thermal electric power plants  

SciTech Connect

Thermal configurations for condensation, district heating, and discharge steam-gas systems (PGU) based on the GTE-65 gas turbine power unit are described. A comparative multivariant analysis of their thermodynamic efficiency is made. Based on some representative examples, it is shown that steam-gas systems with the GTE-65 and boiler-utilizer units can be effectively used and installed in existing main buildings during technical refitting of operating thermal electric power plants.

Lebedev, A. S.; Kovalevskii, V. P. ['Leningradskii Metallicheskii Zavod', branch of JSC 'Silovye mashiny' (Russian Federation); Getmanov, E. A.; Ermaikina, N. A. ['Institut Teploenergoproekt', branch of JSC 'Inzhenernyi tsentr EES' (Russian Federation)

2008-07-15T23:59:59.000Z

240

Tampa Electric Company, Polk Power Station Unit No. 1, preliminary public design report  

Science Conference Proceedings (OSTI)

This preliminary Public Design Report (PDR) provides design information about Tampa Electric Company`s Polk Power Station Unit No. 1, which will demonstrate in a commercial 250 MW unit the benefits of the integration of oxygen-blown, entrained-flow coal gasification with advanced combined cycle technology. This project is partially funded by the US Department of Energy (DOE) under Round III of its Clean Coal Technology (CCT) Program under the provisions of Cooperative Agreement between DOE and Tampa Electric Company, novated on March 5,1992. The project is highlighted by the inclusion of a new hot gas cleanup system. DOE`s project management is based at its Morgantown Energy Technology Center (METC) in West Virginia. This report is preliminary, and the information contained herein is subject to revision. Definitive information will be available in the final PDR, which will be published at the completion of detailed engineering.

NONE

1994-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Dilution Refrigeration of Multi-Ton Cold Masses  

E-Print Network (OSTI)

Dilution refrigeration is the only means to provide continuous cooling at temperatures below 250 mK. Future experiments featuring multi-ton cold masses require a new generation of dilution refrigeration systems, capable of providing a heat sink below 10 mK at cooling powers which exceed the performance of present systems considerably. This thesis presents some advances towards dilution refrigeration of multi-ton masses in this temperature range. A new method using numerical simulation to predict the cooling power of a dilution refrigerator of a given design has been developed in the framework of this thesis project. This method does not only allow to take into account the differences between an actual and an ideal continuous heat exchanger, but also to quantify the impact of an additional heat load on an intermediate section of the dilute stream. In addition, transient behavior can be simulated. The numerical model has been experimentally verified with a dilution refrigeration system which has been designed, ...

Wikus, P; CERN. Geneva

2007-01-01T23:59:59.000Z

242

Cryogenic refrigeration apparatus  

DOE Patents (OSTI)

A technique for producing a cold environment in a refrigerant system in which input fluid from a compressor at a first temperature is introduced into an input channel of the system and is pre-cooled to a second temperature for supply to one of at least two stages of the system, and to a third temperature for supply to another stage thereof. The temperatures at such stages are reduced to fourth and fifth temperatures below the second and third temperatures, respectively. Fluid at the fourth temperature from the one stage is returned through the input channel to the compressor and fluid at the fifth temperature from the other stage is returned to the compressor through an output channel so that pre-cooling of the input fluid to the one stage occurs by regenerative cooling and counterflow cooling and pre-cooling of the input fluid to the other stage occurs primarily by counterflow cooling.

Crunkleton, James A. (Cambridge, MA)

1992-01-01T23:59:59.000Z

243

Cryogenic refrigeration apparatus  

DOE Patents (OSTI)

A technique for producing a cold environment in a refrigerant system in which input fluid from a compressor at a first temperature is introduced into an input channel of the system and is pre-cooled to a second temperature for supply to one of at least two stages of the system, and to a third temperature for supply to another stage thereof. The temperatures at such stages are reduced to fourth and fifth temperatures below the second and third temperatures, respectively. Fluid at the fourth temperature from the one stage is returned through the input channel to the compressor and fluid at the fifth temperature from the other stage is returned to the compressor through an output channel so that pre-cooling of the input fluid to the one stage occurs by regenerative cooling and counterflow cooling and pre-cooling of the input fluid to the other stage occurs primarily by counterflow cooling. 6 figs.

Crunkleton, J.A.

1992-03-31T23:59:59.000Z

244

Small power systems study technical summary report. Volume II. Inventory of small generating units in U. S. utility systems  

SciTech Connect

Data identifying small (less than or equal to 10 MW) power units in the United States are tabulated. The data are listed alphabetically by state and are reported sequentially for investor owned utilities, municipal utilities, and electrical cooperatives and other utility systems. For a given utility system, the generating units are divided into steam turbines, diesel generators and gas turbines. The number and size of generating units are listed. A summary tabulation of the number of generating units of each type and total generating capacity by state is presented.

Sitney, L.R.

1978-05-31T23:59:59.000Z

245

European legislation in the United Kingdom: a threat to coal-fired power station product utilization?  

SciTech Connect

The author considers that the European Union has not taken the approach adopted in the USA where environmental regulators are keen to promote the use of coal-fired power station ash by-product and recycled materials. The United Kingdom has seen, with some dismay, the effects EU legislation is having on the ash industry. This article outlines only some of the problems being tackled. The Waste Framework Directive is difficult to interpret and fails to define critical aspects of the problem. This directive is discussed at some length in the article. A total of nine directives effect the operation of coal-fired power plant. Many are imprecise and open to interpretation and cause a deal of frustration, delays and confusion to the ash supplier and contractor. This is causing markets to suffer.

Sear, K.A. [Quality Ash Association (United Kingdom)

2006-07-01T23:59:59.000Z

246

Wind Power Price Trends in the United States: Struggling to Remain Competitive in the Face of Strong Growth  

E-Print Network (OSTI)

Wind Power Capacity Incremental Capacity (2007, MW) United States China Spain Germany IndiaWind Generation as % of Electricity Consumption Austria Germany Denmark Australia Canada Norway Indiaand India (BTM Consult, 2008). With major development now occurring on several continents, wind

Bolinger, Mark A

2009-01-01T23:59:59.000Z

247

Wind/hybrid power system test facilities in the United States and Canada  

SciTech Connect

By 1995, there will be four facilities available for testing of wind/hybrid power systems in the United States and Canada. This paper describes the mission, approach, capabilities, and status of activity at each of these facilities. These facilities have in common a focus on power systems for remote, off-grid locations that include wind energy. At the same time, these facilities have diverse, yet complimentary, missions that range from research to technology development to testing. The first facility is the test facility at the Institut de Recherche d`Hydro-Quebec (IREQ), Hydro-Quebec`s research institute near Montreal, Canada. This facility, not currently in operation, was used for initial experiments demonstrating the dynamic stability of a high penetration, no-storage wind/diesel (HPNSWD) concept. The second facility is located at the Atlantic Wind Test Site (AWTS) on Prince Edward Island, Canada, where testing of the HPNSWD concept developed by Hydro-Quebec is currently underway. The third is the Hybrid Power Test Facility planned for the National Wind Technology Center at the National Renewable Energy Laboratory (NREL) in Golden, Colorado, which will focus on testing commercially available hybrid power systems. The fourth is the US Department of Agriculture (USDA) Conservation and Production Research Laboratory in Bushland, Texas, where a test laboratory is being developed to study wind-energy penetration and control strategies for wind/hybrid systems. The authors recognize that this summary of test facilities is not all inclusive; for example, at least one US industrial facility is currently testing a hybrid power system. Our intent, though, is to describe four facilities owned by nonprofit or governmental institutions in North America that are or will be available for ongoing development of wind/hybrid power systems.

Green, H J [National Renewable Energy Lab., Golden, CO (United States); Clark, R N [USDA Conservation and Production Research Laboratory, Bushland, TX (United States); Brothers, C [Atlantic Wind Test Site, North Cape, PE (Canada); Saulnier, B [Institut de Recherche d`Hydro-Quebec, Varennes, PQ (Canada)

1994-05-01T23:59:59.000Z

248

Magnetic refrigeration apparatus and method  

SciTech Connect

The disclosure relates to refrigeration through magnetizing and demagnitizing a body by rotating it within a magnetic field. Internal and external heat exchange fluids and in one embodiment, a regenerator, are used.

Barclay, John A. (Los Alamos, NM); Overton, Jr., William C. (Los Alamos, NM); Stewart, Walter F. (Los Alamos, NM)

1984-01-01T23:59:59.000Z

249

Efforts to Reduce the Impacts of Hydroelectric Power Production on Reservoir Fisheries in the United States.  

DOE Green Energy (OSTI)

Research into the environmental effects of hydroelectric power production in the United States has focused increasingly on resident and migratory fish populations. Hydropower dams and reservoirs can block fish movements in both upstream and downstream directions. These movements are essential for important stocks of anadromous and catadromous fish. In addition, some strictly freshwater fish may move long distances within a river during their life cycle.A dam can pose an impassable barrier for fish trying to move upstream unless mitigation measures in the form of ladders or lifts are provided. Fish moving downstream to the sea may become disoriented when they encounter static water within a reservoir. Both resident and migratory fish may be injured or killed by passing through the turbine or over the spillway. In the United States, a variety of organizations conduct applied research and development of measures to (1) enhance fish passage, (2) reduce the numbers of fish that are drawn into the turbine intakes, and (3) reduce the injury and mortality rates of fish that pass through the turbines. Examples of these efforts from a variety of river systems and hydroelectric power plants are described.

Cada, G. F.

1997-09-08T23:59:59.000Z

250

Compressor and Turbine Models of Brayton Units for Space Nuclear Power Systems  

SciTech Connect

Closed Brayton Cycles with centrifugal flow, single-shaft turbo-machines are being considered, with gas cooled nuclear reactors, to provide 10's to 100's of electrical power to support future space exploration missions and Lunar and Mars outposts. Such power system analysis is typically based on the cycle thermodynamics, for given operating pressures and temperatures and assumed polytropic efficiencies of the compressor and turbine of the Brayton energy conversion units. Thus the analysis results not suitable for modeling operation transients such as startup and changes in the electric load. To simulate these transients, accurate models of the turbine and compressor in the Brayton rotating unit, which calculate the changes in the compressor and turbine efficiencies with system operation are needed. This paper presents flow models that account for the design and dimensions of the compressor impeller and diffuser, and the turbine stator and rotor blades. These models calculate the various enthalpy losses and the polytropic efficiencies along with the pressure ratios of the turbine and compressor. The predictions of these models compare well with reported performance data of actual hardware. In addition, the results of a parametric analysis to map the operations of the compressor and turbine, as functions of the rotating shaft speed and inlet Mach number of the gas working fluid, are presented and discussed. The analysis used a binary mixture of He-Xe with a molecular weight of 40 g/mole as the working fluid.

Gallo, Bruno M.; El-Genk, Mohamed S.; Tournier, Jean-Michel [Institute for Space and Nuclear Power Studies, University of New Mexico, Albuquerque, NM, 87131 (United States); Chemical and Nuclear Engineering Department, University of New Mexico, Albuquerque, NM, 87131 (United States)

2007-01-30T23:59:59.000Z

251

Combustion systems and power plants incorporating parallel carbon dioxide capture and sweep-based membrane separation units to remove carbon dioxide from combustion gases  

SciTech Connect

Disclosed herein are combustion systems and power plants that incorporate sweep-based membrane separation units to remove carbon dioxide from combustion gases. In its most basic embodiment, the invention is a combustion system that includes three discrete units: a combustion unit, a carbon dioxide capture unit, and a sweep-based membrane separation unit. In a preferred embodiment, the invention is a power plant including a combustion unit, a power generation system, a carbon dioxide capture unit, and a sweep-based membrane separation unit. In both of these embodiments, the carbon dioxide capture unit and the sweep-based membrane separation unit are configured to be operated in parallel, by which we mean that each unit is adapted to receive exhaust gases from the combustion unit without such gases first passing through the other unit.

Wijmans, Johannes G. (Menlo Park, CA); Merkel, Timothy C (Menlo Park, CA); Baker, Richard W. (Palo Alto, CA)

2011-10-11T23:59:59.000Z

252

Measured Effects of Retrofits - A Refrigerant Oil Additive and a Condenser Spray Device - On the Cooling Performance of a Heat Pump  

E-Print Network (OSTI)

A 15-year old, 3-ton single package air-to-air heat pump was tested in laboratory environmental chambers simulating indoor and outdoor conditions. After documenting initial performance, the unit was retrofitted with a prototype condenser water-spray device and retested. Results at standard AM cooling rating conditions (95°F outdoor dry bulb and 80167 OF indoor dry bulb/wet bulb temperatures) showed the capacity increased by about 7%, and the electric power demand dropped by about 8%, resulting in a steady-state EER increase of 17%. Suction and discharge pressures were reduced by 7 and 37 psi, respectively. A refrigerant oil additive formulated to enhance refrigerant-side heat transfer was added at a dose of one ounce per ton of rated capacity. and the unit was tested for several days at the same 95°F outdoor conditions and showed essentially no increase in capacity, and a slight 3% increase in steady-state EER. Adding more additive lowered the EER slightly. Suction and discharge pressures were essentially unchanged. Our short-term testing showed that the condenser-spray device was effective in increasing the cooling capacity and lowering the electrical demand on an old and relatively inefficient heat pump, but the refrigerant additive had little effect on the cooling performance of our unit Sprayer issues to be resolved include the effect of a sprayer on a new, high-efficiency air conditioner/heat pump, reliable long-term operation, and economics.

Levins, W. P.; Sand, J. R.; Baxter, V. D.; Linkous, R. S.

1996-01-01T23:59:59.000Z

253

Evaluating energy dissipation during expansion in a refrigeration cycle using flue pipe acoustic resonators  

E-Print Network (OSTI)

This research evaluates the feasibility of using a flue pipe acoustic resonator to dissipate energy from a refrigerant stream in order to achieve greater cooling power from a cryorefrigeration cycle. Two models of the ...

Luckyanova, Maria N. (Maria Nickolayevna)

2008-01-01T23:59:59.000Z

254

Optimization of renewable power system for small scale seawater reverse osmosis desalination unit in Mrair-Gabis village, Libya  

Science Conference Proceedings (OSTI)

Potential of renewable power system for small scale seawater reverse osmosis desalination unit in Mrair-Gabis village, Libya is evaluated. HOMER optimization model is used to evaluate the different possible configuration options for supplying the electrical ... Keywords: HOMER, Mrair-Gabis-Libya, power system, reverse osmosis seawater desalination

Kh. Abulqasem; M. A. Alghoul; M. N. Mohammed; Alshrif. Mustafa; Kh. Glaisa; Nowshad. Amin; A. Zaharim; K. Sopian

2011-07-01T23:59:59.000Z

255

Counter-Top Thermoacoustic Refrigerator- An Experimental Investigation  

SciTech Connect

Thermoacoustic phenomenon is a new alternative refrigeration technology. Though design and fabrication is complex for getting the desired effect, it is environmentally friendly and successful system showed that it is relatively easy to run compared to the traditional vapor compression refrigeration system. Currently, theories supporting the thermoacoustic refrigeration systems are yet to be comprehensive to make them commercially viable. Theoretical, experimental, and numerical studies are being done to address the thermodynamics-acoustics interactions. In this study, experimental investigations were completed to test the feasibility of the practical use of a thermoacoustic refrigerator in its counter-top form for future specific application. The system was designed and fabricated based on linear acoustic theory. Acoustic power was given by a loud speaker and thermoacoustic effects were measured in terms of the cooling effects produced at resonanance. Investigations showed that discrepancies between designed and working resonance frequency exist. Thermoacoutic cooling improved at a certain frequency, achieved when the working frequency was varied away from the design frequency. A cooling effect of 4.8 K below the ambient temperature of 23.3 deg. C was obtained from the counter-top thermoacoustic system. This system uses no refrigerants and no compressor to generate the cooling effect, a potential to be further investigated for a practical system.

Anwar, Mahmood; Ghazali, Normah Mohd [Department of Thermo-Fluids, Faculty of Mechanical Engineering, Universiti Teknologi Malaysia Skudai 81310, Johor (Malaysia)

2010-06-28T23:59:59.000Z

256

Integrated Gasification Combined Cycle (IGCC) demonstration project, Polk Power Station -- Unit No. 1. Annual report, October 1993--September 1994  

SciTech Connect

This describes the Tampa Electric Company`s Polk Power Station Unit 1 (PPS-1) Integrated Gasification Combined Cycle (IGCC) demonstration project which will use a Texaco pressurized, oxygen-blown, entrained-flow coal gasifier to convert approximately 2,300 tons per day of coal (dry basis) coupled with a combined cycle power block to produce a net 250 MW electrical power output. Coal is slurried in water, combined with 95% pure oxygen from an air separation unit, and sent to the gasifier to produce a high temperature, high pressure, medium-Btu syngas with a heat content of about 250 Btu/scf (LHV). The syngas then flows through a high temperature heat recovery unit which cools the syngas prior to its entering the cleanup systems. Molten coal ash flows from the bottom of the high temperature heat recovery unit into a water-filled quench chamber where it solidifies into a marketable slag by-product.

NONE

1995-05-01T23:59:59.000Z

257

Fuel Cell Power Electronics – Status & Challenges Tejinder ...  

Science Conference Proceedings (OSTI)

... Fuel cell powered critical refrigeration loads, preventing ... Ref. CL&P Connecticut Outage Map for October 2011 Fuel Cells: Power Through the Storm ...

2012-07-27T23:59:59.000Z

258

Demand Response Opportunities in Industrial Refrigerated Warehouses in California  

Science Conference Proceedings (OSTI)

Industrial refrigerated warehouses that implemented energy efficiency measures and have centralized control systems can be excellent candidates for Automated Demand Response (Auto-DR) due to equipment synergies, and receptivity of facility managers to strategies that control energy costs without disrupting facility operations. Auto-DR utilizes OpenADR protocol for continuous and open communication signals over internet, allowing facilities to automate their Demand Response (DR). Refrigerated warehouses were selected for research because: They have significant power demand especially during utility peak periods; most processes are not sensitive to short-term (2-4 hours) lower power and DR activities are often not disruptive to facility operations; the number of processes is limited and well understood; and past experience with some DR strategies successful in commercial buildings may apply to refrigerated warehouses. This paper presents an overview of the potential for load sheds and shifts from baseline electricity use in response to DR events, along with physical configurations and operating characteristics of refrigerated warehouses. Analysis of data from two case studies and nine facilities in Pacific Gas and Electric territory, confirmed the DR abilities inherent to refrigerated warehouses but showed significant variation across facilities. Further, while load from California's refrigerated warehouses in 2008 was 360 MW with estimated DR potential of 45-90 MW, actual achieved was much less due to low participation. Efforts to overcome barriers to increased participation may include, improved marketing and recruitment of potential DR sites, better alignment and emphasis on financial benefits of participation, and use of Auto-DR to increase consistency of participation.

Goli, Sasank; McKane, Aimee; Olsen, Daniel

2011-06-14T23:59:59.000Z

259

Tampa Electric Company Polk Power Station Unit Number 1. Annual report, January--December, 1993  

Science Conference Proceedings (OSTI)

This report satisfies the requirements of Cooperative Agreement DE-FC21-91MC27363, novated as of March 5, 1992, to provide an annual update report on the year`s activities associated with Tampa Electric Company`s 250 MW IGCC demonstration project for the year 1993. Tampa Electric Company`s Polk Power Station Unit 1 (PPS-1) Integrated Gasification Combined Cycle (IGCC) demonstration project will use a Texaco pressurized, oxygen-blown, entrained-flow coal gasifier to convert approximately 2,000 tons per day of coal (dry basis) coupled with a combined cycle power block to produce a net 250 MW electrical power output. Approximately 50% of the raw, hot syngas is cooled to 900 F and passed through a moving bed of zinc-based sorbent which removes sulfur containing compounds from the syngas. The remaining portion of the raw, hot syngas is cooled to 400 F for conventional acid gas removal. Sulfur-bearing compounds from both cleanup systems are sent to a conventional sulfuric acid plant to produce a marketable, high-purity sulfuric acid by-product. The cleaned medium-BTU syngas from these processes is routed to the combined cycle power generation system where it is mixed with air and burned in the combustion section of the combustion turbine. Heat is extracted from the expanded exhaust gases in a heat recovery steam generator (HRSG) to produce steam at three pressure levels for use throughout the integrated process. A highly modular, microprocessor-based distributed control system (DCS) is being developed to provide continuous and sequential control for most of the equipment on PPS-1.

Not Available

1994-08-01T23:59:59.000Z

260

Thermal Analysis of Refrigeration Systems Used for Vaccine ...  

Science Conference Proceedings (OSTI)

Page 1. Thermal Analysis of Refrigeration Systems Used for Vaccine Storage ... Suitability of commercial refrigerators for vaccine storage not ...

2012-08-03T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

COMPUTER DESIGN AND OPTIMIZATION OF CRYOGENIC REFRIGERATION SYSTEMS  

E-Print Network (OSTI)

One Stage Compressor Heat Exchanger Refrigeration Load XBLOne Stage Compressor Heat Exchanger Refrigeration Load XBLcondensers, surface heat exchangers, surface condensers,

green, M.A.

2011-01-01T23:59:59.000Z

262

Land-Use Requirements for Solar Power Plants in the United States  

DOE Green Energy (OSTI)

This report provides data and analysis of the land use associated with utility-scale ground-mounted solar facilities, defined as installations greater than 1 MW. We begin by discussing standard land-use metrics as established in the life-cycle assessment literature and then discuss their applicability to solar power plants. We present total and direct land-use results for various solar technologies and system configurations, on both a capacity and an electricity-generation basis. The total area corresponds to all land enclosed by the site boundary. The direct area comprises land directly occupied by solar arrays, access roads, substations, service buildings, and other infrastructure. As of the third quarter of 2012, the solar projects we analyze represent 72% of installed and under-construction utility-scale PV and CSP capacity in the United States.

Ong, S.; Campbell, C.; Denholm, P.; Margolis, R.; Heath, G.

2013-06-01T23:59:59.000Z

263

RADIOISOTOPE FUELED AUXILIARY POWER UNIT. Quarterly Progress Report No. 6, April 1958-July 1958  

SciTech Connect

A modular concept has evolved which permits testing of SNAP-1 as an attachable unit. Integrity testing of fuel elements in simulated pad aborts is reported. The adequacy of a full-scale boiler mockup in vaporizing mercury at the design point was tested; a new boiler coil designed to prevent slugging was tested. The sintering properties of CeO/sub 2/ were further investigated. Dynamic mercury corrosion testing of Croloy 5 Si and Croloy 5 Ti is reported. Static lead tests of CeO/sub 2/ pellets, brazed joints, and flame sprayed coatings continued. Testing of the power conversion system turbine, centrifugal pumps, controls, radial gap alternator, bearings, and steels is described. Design of a facility for testing the APU module is under way. A conceptual design of SNAP-3 was delineated. (N.W.R.)

1963-10-31T23:59:59.000Z

264

Impacts from Deployment Barriers on the United States Wind Power Industry: Overview & Preliminary Findings (Presentation)  

DOE Green Energy (OSTI)

Regardless of cost and performance some wind projects are unable to proceed to commissioning as a result of deployment barriers. Principal deployment barriers in the industry today include: wildlife, public acceptance, access to transmission, and radar. To date, methods for understanding these non-technical barriers have failed to accurately characterize the costs imposed by deployment barriers and the degree of impact to the industry. Analytical challenges include limited data and modeling capabilities. Changes in policy and regulation, among other factors, also add complexity to analysis of impacts from deployment barriers. This presentation details preliminary results from new NREL analysis focused on quantifying the impact of deployment barriers on the wind resource of the United States, the installed cost of wind projects, and the total electric power system cost of a 20% wind energy future. In terms of impacts to wind project costs and developable land, preliminary findings suggest that deployment barriers are secondary to market drivers such as demand. Nevertheless, impacts to wind project costs are on the order of $100/kW and a substantial share of the potentially developable windy land in the United States is indeed affected by deployment barriers.

Lantz, E.; Tegen, S.; Hand, M.; Heimiller, D.

2012-09-01T23:59:59.000Z

265

The Super Efficient Refrigerator Program: Case study of a Golden Carrot program  

Science Conference Proceedings (OSTI)

The work in this report was conducted by the Analytic Studies Division (ASD) of the National Renewable Energy Laboratory (NREL) for the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy, Office of Building Technologies. This case study describes the development and implementation of the Super Efficient Refrigerator Program (SERP), which awarded $30 million to the refrigerator manufacturer that developed and commercialized a refrigerator that exceeded 1993 federal efficiency standards by at least 25%. The program was funded by 24 public and private utilities. As the first Golden Carrot program to be implemented in the United States, SERP was studied as an example for future `market-pull` efforts.

Eckert, J B

1995-07-01T23:59:59.000Z

266

International Refrigeration: Order (2012-CE-1510)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered International Refrigeration Products to pay an $8,000 civil penalty after finding International Refrigeration had failed to certify that certain room air conditioners comply with the applicable energy conservation standard.

267

Cospolich Refrigerator: Order (2013-CE-5314)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered Cospolich Refrigerator Co, Inc. to pay a $8,000 civil penalty after finding Cospolich Refrigerator had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

268

Thermoelectric refrigerator having improved temperature stabilization means  

DOE Patents (OSTI)

A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature, but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized.

Falco, Charles M. (Woodridge, IL)

1982-01-01T23:59:59.000Z

269

SMALL POWER REACTOR PROJECTS OF THE UNITED STATES ATOMIC ENERGY COMMISSION  

SciTech Connect

Information on small power reactor projects of the USAEC is summarized. General information concerning the projects as a whole is given. Specific projects discussed include: the Elk River Power Reactor, the Piqua Nuclear Power Facility, the BONUS Power Reactor, the Pathfinder Power Reactor, the small-size pressurized water power reactor, and the experimental low-power process heat reactor. (M.C.G.)

1961-09-28T23:59:59.000Z

270

Fuel Preprocessor (FPP) for a Solid Oxide Fuel Cell Auxiliary Power Unit  

DOE Green Energy (OSTI)

Auxiliary Power Units (APUs), driven by truck engines, consume over 800 million gallon of diesel fuel while idling. Use of separate SOFC based APUs are an excellent choice to reduce the cost and pollution associated with producing auxiliary power. However, diesel fuel is a challenging fuel to use in fuel cell systems because it has heavy hydrocarbons that can transform into carbon deposits and gums that can block passages and deactivate fuel reformer and fuel cell reactor elements. The work reported herein addresses the challenges associated with the diesel fuel sulfur and carbon producing contaminants in a Fuel Preprocessor (FPP). FPP processes the diesel fuel onboard and ahead of the reformer to reduce its carbon deposition tendency and its sulfur content, thus producing a fuel suitable for SOFC APU systems. The goal of this DOE supported Invention and Innovation program was to design, develop and test a prototype Fuel Preprocessor (FPP) that efficiently and safely converts the diesel fuel into a clean fuel suitable for a SOFC APU system. The goals were achieved. A 5 kWe FPP was designed, developed and tested. It was demonstrated that FPP removes over 80% of the fuel sulfur and over 90% of its carbon residues and it was demonstrated that FPP performance exceeds the original project goals.

M. Namazian, S. Sethuraman and G. Venkataraman

2004-12-31T23:59:59.000Z

271

Impact of High Wind Power Penetration on Hydroelectric Unit Operations: Preprint  

DOE Green Energy (OSTI)

This paper examines the impact of this large amount of wind penetration on hydroelectric unit operations. Changes in hydroelectric unit operating unit patterns are examined for an aggregation of all hydro generators.

Hodge, B. M.; Lew, D.; Milligan, M.

2011-10-01T23:59:59.000Z

272

Making european-style community wind power development work in the United States  

E-Print Network (OSTI)

Support for Community Wind Power Development. LBNL-54715.at 2003 Oklahoma Wind Power and Bioenergy Conference, JuneWind. 2001. Distributed Wind Power Assessment. Prepared for

Bolinger, Mark A.

2004-01-01T23:59:59.000Z

273

Supporting Solar Power in Renewables Portfolio Standards: Experience from the United States  

E-Print Network (OSTI)

mechanisms to support wind power development." Renewablebe competitive with wind power and other forms of renewabletechnologies (e.g. , wind power). As a prime illustration of

Wiser, Ryan

2010-01-01T23:59:59.000Z

274

Community wind power ownership schemes in Europe and their relevance to the United States  

E-Print Network (OSTI)

Andersen, P.D. 1998. Wind Power in Denmark: Technology,Inc. 1998. Distributed Wind Power Assessment. Draft reportwww.stem.se Swedish Wind Power Association. 2001. Current

Bolinger, Mark

2001-01-01T23:59:59.000Z

275

DOE Proposes Higher Efficiency Standards for Refrigerators  

Energy.gov (U.S. Department of Energy (DOE))

New Proposed Standards for Residential Refrigerators and Freezers to Lower Energy Use by as much as Twenty-Five Percent

276

Magnetocaloric Effect and Enhanced Refrigeration effectiveness in ...  

Science Conference Proceedings (OSTI)

Presentation Title, Magnetocaloric Effect and Enhanced Refrigeration effectiveness in ... Industrial Needs and Applications for Soft Magnetic Materials · Industrial ...

277

Optimization of the Refrigerant Capacity in Multiphase ...  

Science Conference Proceedings (OSTI)

Symposium, Magnetic Materials for Energy Applications. Presentation Title, Optimization of the Refrigerant Capacity in Multiphase Magnetocaloric Materials.

278

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with Capillary Tube Expansion  

E-Print Network (OSTI)

The effect of the improper charging on the performance (capacity, EER, power consumption, SEER, and coefficient of degradation) of a residential air conditioner during the steady state (wet and dry coils) and cycling operation was investigated. The fully charged condition was established as a base case. A full charge was obtained charging the unit to the superheat specified by the manufacturer's charging chart for specific set of indoor and outdoor temperatures. Once the full charge was determined, the unit was subjected to 20%, 15%, 10%, and 5% under and overcharging of refrigerant (by mass). The fully charged tests were compared to under and overcharging. The performance of the unit was evaluated as a function of charge as well as at four outdoor room temperatures (82°F, 90°F, 95°F, and 100°F). As the outdoor temperature increased, the total capacity and EER dropped. The investigation of improper charging showed that the total capacity, EER, and SEER were more sensitive to undercharging than overcharging conditions. A 20% undercharge resulted in a 21% reduction in SEER while a 20% overcharge produced a 11% reduction in SEER. Other data such as refrigerant flow rate, sensible heat ratio, superheat and subcooling are also presented.

Farzad, M.; O'Neal, D. L.

1988-01-01T23:59:59.000Z

279

Lessons Learned: Designing Successful Green Power Services: Phase II - Assessment of Green Power Products and Services in the United States  

Science Conference Proceedings (OSTI)

"Green power" -- electricity produced from renewable resources -- has emerged as a key product in the restructuring of electricity markets around the world. Residential and commercial end-use customers have been able to purchase green-power products everywhere that retail competition is allowed, and the "greenness" of power products is universally recognized as a unique product differentiator in competitive markets. This report focuses on green-power marketing and green-power products in states where a c...

2002-04-11T23:59:59.000Z

280

Ternary Dy-Er-Al magnetic refrigerants  

DOE Patents (OSTI)

A ternary magnetic refrigerant material comprising (Dy{sub 1{minus}x}Er{sub x})Al{sub 2} for a magnetic refrigerator using the Joule-Brayton thermodynamic cycle spanning a temperature range from about 60K to about 10K, which can be adjusted by changing the Dy to Er ratio of the refrigerant. 29 figs.

Gschneidner, K.A. Jr.; Takeya, Hiroyuki

1995-07-25T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Method and apparatus for desuperheating refrigerant  

DOE Patents (OSTI)

The present invention is an apparatus and method for de-superheating a primary refrigerant leaving a compressor wherein a secondary refrigerant is used between the primary refrigerant to be de-superheated. Reject heat is advantageously used for heat reclaim.

Zess, James A. (Kelso, WA); Drost, M. Kevin (Richland, WA); Call, Charles J. (Richland, WA)

1997-01-01T23:59:59.000Z

282

Ternary Dy-Er-Al magnetic refrigerants  

DOE Patents (OSTI)

A ternary magnetic refrigerant material comprising (Dy.sub.1-x Er.sub.x)Al.sub.2 for a magnetic refrigerator using the Joule-Brayton thermodynamic cycle spanning a temperature range from about 60K to about 10K, which can be adjusted by changing the Dy to Er ratio of the refrigerant.

Gschneidner, Jr., Karl A. (Ames, IA); Takeya, Hiroyuki (Ibaraki, JP)

1995-07-25T23:59:59.000Z

283

Wheel-type magnetic refrigerator  

DOE Patents (OSTI)

The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load.

Barclay, John A. (Los Alamos, NM)

1983-01-01T23:59:59.000Z

284

Wheel-type magnetic refrigerator  

DOE Patents (OSTI)

The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load.

Barclay, J.A.

1982-01-20T23:59:59.000Z

285

Wheel-type magnetic refrigerator  

DOE Patents (OSTI)

The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load. 7 figs.

Barclay, J.A.

1983-10-11T23:59:59.000Z

286

Investigation of Chlorine-Free Refrigerants for Low-Temperature Supermarket Refrigeration  

Science Conference Proceedings (OSTI)

With the phaseout of chlorofluorocarbon (CFC) refrigerants, supermarkets are seeking a replacement for R-502, the refrigerant of choice for low-temperature (frozen food) refrigeration. EPRI has conducted field testing to characterize the performance of the new hydrofluorocarbon (HFC) nonchlorinated refrigerants replacements for R-502. Results showed that energy and demand savings can be obtained using these alternative refrigerants with zero ozone-depleting potential.

1996-08-10T23:59:59.000Z

287

Advanced Refrigerant-Based Cooling Technologies for Information and Communication Infrastructure (ARCTIC)  

SciTech Connect

Faster, more powerful and dense computing hardware generates significant heat and imposes considerable data center cooling requirements. Traditional computer room air conditioning (CRAC) cooling methods are proving increasingly cost-ineffective and inefficient. Studies show that using the volume of room air as a heat exchange medium is wasteful and allows for substantial mixing of hot and cold air. Further, it limits cabinet/frame/rack density because it cannot effectively cool high heat density equipment that is spaced closely together. A more cost-effective, efficient solution for maximizing heat transfer and enabling higher heat density equipment frames can be accomplished by utilizing properly positioned �¢����phase change�¢��� or �¢����two-phase�¢��� pumped refrigerant cooling methods. Pumping low pressure, oil-free phase changing refrigerant through microchannel heat exchangers can provide up to 90% less energy consumption for the primary cooling loop within the room. The primary benefits of such a solution include reduced energy requirements, optimized utilization of data center space, and lower OPEX and CAPEX. Alcatel-Lucent recently developed a modular cooling technology based on a pumped two-phase refrigerant that removes heat directly at the shelf level of equipment racks. The key elements that comprise the modular cooling technology consist of the following. A pump delivers liquid refrigerant to finned microchannel heat exchangers mounted on the back of equipment racks. Fans drive air through the equipment shelf, where the air gains heat dissipated by the electronic components therein. Prior to exiting the rack, the heated air passes through the heat exchangers, where it is cooled back down to the temperature level of the air entering the frame by vaporization of the refrigerant, which is subsequently returned to a condenser where it is liquefied and recirculated by the pump. All the cooling air enters and leaves the shelves/racks at nominally the same temperature. Results of a 100 kW prototype data center installation of the refrigerant-based modular cooling technology were dramatic in terms of energy efficiency and the ability to cool high-heat-density equipment. The prototype data center installation consisted of 10 racks each loaded with 10 kW of high-heat-density IT equipment with the racks arranged in a standard hot-aisle/cold-aisle configuration with standard cabinet spacing. A typical chilled-water CRAC unit would require approximately 16 kW to cool such a heat load. In contrast, the refrigerant-based modular cooling technology required only 2.3 kW of power for the refrigerant pump and shelf-level fans, a reduction of 85 percent. Differences in hot-aisle and cold-aisle temperature were also substantially reduced, mitigating many issues that arise in purely air-based cooling systems, such as mixing of hot and cold air streams, or from placing high-heat-density equipment in close proximity. The technology is also such that it is able to retro-fit live equipment without service interruption, which is particularly important to the large installed ICT customer base, thereby providing a means of mitigating reliability and performance concerns during the installation, training and validation phases of product integration. Moreover, the refrigerant used in our approach, R134a, is a widely-used, non-toxic dielectric liquid which, unlike water, is non-conducting and non-corrosive and will not damage electronics in the case of a leak�¢����a triple-play win over alternative water-based liquid coolant technologies. Finally, through use of a pumped refrigerant, pressures are modest (~60 psi), and toxic lubricants and oils are not required, in contrast to compressorized refrigerant systems�¢����another environmental win. Project Activities - The ARCTIC project goal was to further develop an

Todd Salamon

2012-12-13T23:59:59.000Z

288

A Survey of Water Use and Sustainability in the United States with a Focus on Power Generation  

Science Conference Proceedings (OSTI)

EPRI has identified water resource sustainability and its relation to electric power as one of the key challenges within EPRI's Electricity Technology Roadmap. This report presents an overview of present and future freshwater availability and generation demand for fresh water in the United States. The report takes a first step toward development of a comprehensive framework for evaluating possible impacts of water supply limitations on electric power generation and management approaches to limiting these...

2003-12-03T23:59:59.000Z

289

Low-temperature magnetic refrigerator  

SciTech Connect

The disclosure is directed to a low temperature 4 to 20 K. refrigeration apparatus and method utilizing a ring of magnetic material moving through a magnetic field. Heat exchange is accomplished in and out of the magnetic field to appropriately utilize the device to execute Carnot and Stirling cycles.

Barclay, John A. (Los Alamos, NM)

1985-01-01T23:59:59.000Z

290

MEASUREMENTS OF THE CONFINEMENT LEAKTIGHTNESS AT THE KOLA NUCLEAR POWER STATION (UNIT 2) IN RUSSIA  

Science Conference Proceedings (OSTI)

This is the final report on the INSP project entitled, ``Kola Confinement Leaktightness'' conducted by BNL under the authorization of Project Work Plan WBS 1.2.2.1. This project was initiated in February 1993 to assist the Russians to reduce risks associated with the continued operation of older Soviet-designed nuclear power plants, specifically the Kola VVER-440/230 Units 1 and 2, through upgrades in the confinement performance to reduce the uncontrolled leakage rate. The major technical objective of this-project was to improve the leaktightness of the Kola NPP VVER confinement boundaries, through the application of a variety of sealants to penetrations, doors and hatches, seams and surfaces, to the extent that current technology permitted. A related objective was the transfer, through training of Russian staff, of the materials application procedures to the staff of the Kola NPP. This project was part of an overall approach to minimizing uncontrolled releases from the Kola NPP VVER440/230s in the event of a serious accident, and to thereby significantly mitigate the consequences of such an accident. The US provided materials, application technology, and applications equipment for application of sealant materials, surface coatings, potting materials and gaskets, to improve the confinement leaktightness of the Kola VVER-440/23Os. The US provided for training of Russian personnel in the applications technology.

GREENE,G.A.; GUPPY,J.G.

1998-08-01T23:59:59.000Z

291

EIS No. 20100312 EIS Comanche Peak Nuclear Power Plant Units 3 and 4  

SciTech Connect

In accordance with Section 309(a) of the Clean Air Act, EPA is required to make its comments on EISs issued by other Federal agencies public. Historically, EPA has met this mandate by publishing weekly notices of availability of EPA comments, which includes a brief summary of EPA's comment letters, in the Federal Register. Since February 2008, EPA has been including its comment letters on EISs on its Web site at: http://www.epa.gov/compliance/nepa/eisdata.html. Including the entire EIS comment letters on the Web site satisfies the Section 309(a) requirement to make EPA's comments on EISs available to the public. Accordingly, on March 31, 2010, EPA discontinued the publication of the notice of availability of EPA comments in the Federal Register. EIS No. 20100312, Draft EIS, NRC, TX, Comanche Peak Nuclear Power Plant Units 3 and 4, Application for Combined Licenses (COLs) for Construction Permits and Operating Licenses, (NUREG-1943), Hood and Somervell Counties, TX, Comment Period Ends: 10/26/2010.

Bjornstad, David J [ORNL

2010-08-01T23:59:59.000Z

292

Indianapolis Power & Light - Residential Energy Incentives Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Indianapolis Power & Light - Residential Energy Incentives Program Indianapolis Power & Light - Residential Energy Incentives Program Indianapolis Power & Light - Residential Energy Incentives Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Program Info State Indiana Program Type Utility Rebate Program Rebate Amount CFLs: In store discounts A/C Cycling: $20/summer Split System AC: $300 - $400 Air Source Heat Pump: $200 - $300 Home Energy Evaluation and Energy Efficiency Kit: Free Refrigerator/Freezer Recycling: $30/unit Provider IPL Energy Incentives Program The Indianapolis Power and Light Energy Incentives Programs assist residential customers with reducing energy consumption. The program offers

293

Supporting Solar Power in Renewables Portfolio Standards: Experience from the United States  

E-Print Network (OSTI)

L ABORATORY Supporting Solar Power in Renewables PortfolioLBNL- 3984E Supporting Solar Power in Renewables Portfolioof the concentrating solar power (CSP) market in the U.S.

Wiser, Ryan

2010-01-01T23:59:59.000Z

294

Impact of High Wind Power Penetration on Hydroelectric Unit Operations in the WWSIS  

DOE Green Energy (OSTI)

This report examines the impact of this large amount of wind penetration on hydroelectric unit operations. Changes in hydroelectric unit operating patterns are examined both for an aggregation of all hydro generators and for select individual plants.

Hodge, B.-M.; Lew, D.; Milligan, M.

2011-07-01T23:59:59.000Z

295

Community wind power ownership schemes in Europe and their relevance to the United States  

E-Print Network (OSTI)

the Nuclear Power Decommissioning Act, which gives thetrend towards nuclear decommissioning that has been driving

Bolinger, Mark

2001-01-01T23:59:59.000Z

296

Duracold Refrigeration Manufacturing: Order (2013-CE-5342) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Duracold Refrigeration Manufacturing: Order (2013-CE-5342) Duracold Refrigeration Manufacturing: Order (2013-CE-5342) Duracold Refrigeration Manufacturing: Order (2013-CE-5342) April 25, 2013 DOE ordered Duracold Refrigeration Manufacturing Company, LLC to pay a $8,000 civil penalty after finding Duracold Refrigeration Manufacturing had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards. The Order adopted a Compromise Agreement, which reflected settlement terms between DOE and Duracold Refrigeration Manufacturing. Duracold Refrigeration Manufacturing: Order (2013-CE-5342) More Documents & Publications Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) North Star Refrigerator: Order (2013-CE-5355) Schott Gemtron: Order (2013-CE-5358

297

Shutdown and low-power operation at commercial nuclear power plants in the United States. Final report  

Science Conference Proceedings (OSTI)

The report contains the results of the NRC Staff`s evaluation of shutdown and low-power operations at US commercial nuclear power plants. The report describes studies conducted by the staff in the following areas: Operating experience related to shutdown and low-power operations, probabilistic risk assessment of shutdown and low-power conditions and utility programs for planning and conducting activities during periods the plant is shut down. The report also documents evaluations of a number of technical issues regarding shutdown and low-power operations performed by the staff, including the principal findings and conclusions. Potential new regulatory requirements are discussed, as well as potential changes in NRC programs. A draft report was issued for comment in February 1992. This report is the final version and includes the responses to the comments along with the staff regulatory analysis of potential new requirements.

Not Available

1993-09-01T23:59:59.000Z

298

China Refrigerator Information Label: Specification Development and Potential Impact  

SciTech Connect

In the last five years, China's refrigerator market has grown rapidly, and now urban markets are showing signs of saturation, with ownership rates in urban households reaching 92%. Rural markets continue to grow from a much lower base. As a result of this growth, the Chinese government in 2006 decided to revise the refrigerator standards and its associated efficiency grades for the mandatory energy information label. In the Chinese standards process, the efficiency grades for the information label are tied to the minimum standards. Work on the minimum standards revision began in 2006 and continued through the first half of 2007, when the draft standard was completed under the direction of the China National Institute of Standardization (CNIS). Development of the information label grades required consideration of stakeholder input, continuity with the previous grade classification, ease of implementation, and potential impacts on the market. In this process, CLASP, with the support of METI/IEEJ, collaborated with CNIS to develop the efficiency grades, providing technical input to the process, comment and advice on particular technical issues, and evaluation of the results. After three months of effort and three drafts of the final grade specifications, this work was completed. In addition, in order to effectively evaluate the impact of the label on China's market, CLASP further provided assistance to CNIS to collect data on both the efficiency distribution and product volume distribution of refrigerators on the market. The new information label thresholds to be implemented in 2008 maintain the approach first adopted in 2005 of establishing efficiency levels relative to the minimum standard, but increased the related required efficiency levels by 20% over those established in 2003 and implemented in 2005. The focus of improvement was on the standard refrigerator/freezer (class 5), which constitutes the bulk of the Chinese market. Indeed, the new requirements to achieve grade 1 on the label are now virtually as stringent as those for US Energy Star-qualified or EU A-grade refrigerators. When the energy information label went into effect in March 2005, refrigerator manufacturers were required to display their declared level of efficiency on the label and report it to the China Energy Label Center (CELC), a newly established unit of CNIS responsible for label program management. Because of the visible nature of the label, it was found, through a METI/IEEJ-supported study, that MEPS non-compliance dropped from 4% to zero after the label became mandatory, and that the percentage of higher-grade refrigerators increased. This suggests that the label itself does have potential for shifting the market to higher-efficiency models (Lin 2007). One challenge, however, of assessing this potential impact is the lack of a comprehensive baseline of market efficiency and a program to evaluate the market impact on a yearly basis. As a result, the impact evaluation in this study draws upon the market transformation experience of the related EU energy information label, for which quantitative assessments of its market impact exist. By assuming a parallel process unfolding in China, it is possible to look at the potential impact of the label to 2020. The results of the analysis demonstrates that a robust market transformation program in China focused on the energy information label could save substantial amounts of electricity by 2020, totaling 16.4 TWh annually by that year, compared to a case in which the efficiency distribution of refrigerators was frozen at the 2007 level. Remarkably, the impact of a successful market transformation program with the label would essentially flatten the consumption of electricity for refrigerator use throughout most of the next decade, despite the expectations of continued growth in total stock by nearly 190 million units. At the end of this period, total consumption begins to rise again, as the least efficient of the units have been mostly removed from the market. Such a level of savings would reduce CO{sub

Fridley, David; Fridley, David; Zheng, Nina; Zhou, Nan; Aden, Nathaniel; Lin, Jiang; Jianhong, Cheng; Sakamoto, Tomoyuki

2008-02-01T23:59:59.000Z

299

FirstEnergy (West Penn Power) - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

West Penn Power) - Residential Energy Efficiency West Penn Power) - Residential Energy Efficiency Rebate Program FirstEnergy (West Penn Power) - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Water Heating Maximum Rebate Room AC/Room AC Recycling: Limit 3 All Other Appliances: Limit 1 per household Program Info State Pennsylvania Program Type Utility Rebate Program Rebate Amount Walk-Through Audit: Reduced customer fee of $50 Whole House Audit: $300 CFL's: $1.50 Clothes Washer: $75 Refrigerator: $50 Freezer: $25 Room AC: $25 Dehumidifiers: $10 Refrigerator Recycling: $50 Freezer Recycling: $50 Room AC Unit Recycling: $25

300

Optimal Performance of Quantum Refrigerators  

E-Print Network (OSTI)

A reciprocating quantum refrigerator is studied with the purpose of determining the limitations of cooling to absolute zero. We find that if the energy spectrum of the working medium possesses an uncontrollable gap, then there is a minimum achievable temperature above zero. Such a gap, combined with a negligible amount of noise, prevents adiabatic following during the demagnetization stage which is the necessary condition for reaching $T_c \\to 0$. The refrigerator is based on an Otto cycle where the working medium is an interacting spin system with an energy gap. For this system the external control Hamiltonian does not commute with the internal interaction. As a result during the demagnetization and magnetization segments of the operating cycle the system cannot follow adiabatically the temporal change in the energy levels. We connect the nonadiabatic dynamics to quantum friction. An adiabatic measure is defined characterizing the rate of change of the Hamiltonian. Closed form solutions are found for a const...

Feldmann, Tova

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Quantum-enhanced absorption refrigerators  

E-Print Network (OSTI)

Thermodynamics is a branch of science blessed by an unparalleled combination of generality of scope and formal simplicity. Based on few natural assumptions together with the four laws, it sets the boundaries between possible and impossible in macroscopic aggregates of matter. This triggered groundbreaking achievements in physics, chemistry and engineering over the last two centuries. Close analogues of those fundamental laws are now being established at the level of individual quantum systems, thus placing limits on the operation of quantum-mechanical devices. Here we study quantum absorption refrigerators, which are driven by heat rather than external work. We establish thermodynamic performance bounds for these machines and investigate their quantum origin. We also show how those bounds may be pushed beyond what is classically achievable, by suitably tailoring the environmental fluctuations via quantum reservoir engineering techniques. Such superefficient quantum-enhanced cooling realises a promising step towards the technological exploitation of autonomous quantum refrigerators.

Luis A. Correa; José P. Palao; Daniel Alonso; Gerardo Adesso

2013-08-19T23:59:59.000Z

302

Suction muffler for refrigeration compressor  

SciTech Connect

A hermetic refrigeration compressor includes a suction muffler formed from two pieces of plastic material mounted on the cylinder housing. One piece is cylindrical in shape with an end wall having an aperture for receiving a suction tube connected to the cylinder head. The other piece fits over and covers the other end of the cylindrical piece, and includes a flaring entrance horn which extends toward the return line on the sidewall of the compressor shell.

Nelson, Richard T. (Worthington, OH); Middleton, Marc G. (West Jefferson, OH)

1983-01-01T23:59:59.000Z

303

Suction muffler for refrigeration compressor  

DOE Patents (OSTI)

A hermetic refrigeration compressor includes a suction muffler formed from two pieces of plastic material mounted on the cylinder housing. One piece is cylindrical in shape with an end wall having an aperture for receiving a suction tube connected to the cylinder head. The other piece fits over and covers the other end of the cylindrical piece, and includes a flaring entrance horn which extends toward the return line on the sidewall of the compressor shell. 5 figs.

Nelson, R.T.; Middleton, M.G.

1983-01-25T23:59:59.000Z

304

Design of a single orifice pulse tube refrigerator through the development of a first-order model  

E-Print Network (OSTI)

A first order model for the behavior of a linear orifice pulse tube refrigerator (OPTR) was developed as a design tool for construction of actual OPTRs. The model predicts cooling power as well as the pressure/volume ...

Schor, Alisha R. (Alisha Robin)

2007-01-01T23:59:59.000Z

305

Compatibility of refrigerants and lubricants with elastomers  

SciTech Connect

Information contained in this reporters designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. Swell measurements have been made on approximately 50% of the proposed elastomers (94 total)in both the lubricant (7 total) and refrigerant (10 total) materials. Swell behavior in the these fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 hours and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1992-07-01T23:59:59.000Z

306

An examination of the pursuit of nuclear power plant construction projects in the United States  

E-Print Network (OSTI)

The recent serious reconsideration of nuclear power as a means for U.S. electric utilities to increase their generation capacity provokes many questions regarding the achievable success of future nuclear power plant ...

Guyer, Brittany (Brittany Leigh)

2011-01-01T23:59:59.000Z

307

Agent-based electrical power management model for houses equipped with storage battery and photovoltaic units  

Science Conference Proceedings (OSTI)

Smart grid systems have been actively discussed to realize a sustainable and a low-carbon society that efficiently consumes electric power and to introduce photovoltaic power generation, i.e., renewable energy or electric vehicles. In this study, we ...

Ryo Kanamori; Takayuki Ito; Nobuyasu Mizutani

2011-12-01T23:59:59.000Z

308

Nuclear power plant performance assessment pertaining to plant aging in France and the United States  

E-Print Network (OSTI)

The effect of aging on nuclear power plant performance has come under increased scrutiny in recent years. The approaches used to make an assessment of this effect strongly influence the economics of nuclear power plant ...

Guyer, Brittany (Brittany Leigh)

2013-01-01T23:59:59.000Z

309

Wind Power Development in the United States: Current Progress, Future Trends  

E-Print Network (OSTI)

to lower the cost of offshore wind power, and incrementallyinstalled offshore. From 2018 to 2030, roughly 16 GW of wind

Wiser, Ryan H

2009-01-01T23:59:59.000Z

310

Supporting Solar Power in Renewables Portfolio Standards: Experience from the United States  

E-Print Network (OSTI)

power sales agreements. Duke Energy North Carolina SolarGeneration Program: Duke Energy plans to install 10 MW of

Wiser, Ryan

2010-01-01T23:59:59.000Z

311

Community wind power ownership schemes in Europe and their relevance to the United States  

E-Print Network (OSTI)

is this trend towards nuclear decommissioning that has beenRiksdag passed the Nuclear Power Decommissioning Act, which

Bolinger, Mark

2001-01-01T23:59:59.000Z

312

Commercial Nuclear Electric Power in the United States: Problems and Prospects  

Reports and Publications (EIA)

This article briefly reviews the origins of commercial nuclear electric power, the efforts to dispose of high-level nuclear waste, the costs of building and operating nuclear electric power plants, and other energy-related developments pertinent to the future of nuclear electric power.

Information Center

1994-08-01T23:59:59.000Z

313

REFRIGERATIONREFRIGERATION ((svsv: Kylteknik): Kylteknik) 424503 E 2010 #4424503 E 2010 #4 --rzrz 4.4. RefrigerationRefrigeration processprocess comparisoncomparison;;f gf g pp pp  

E-Print Network (OSTI)

.100.110.2 Typical refrigerant: R-134a, R- 600a and other hydrocarbons cture:http://1 Air-cooled condensing unit gives some efficiency data from commercial vapour- 3.11.2010 Ã?bo Akademi Univ - Thermal and Flow Engineering Piispankatu 8, 20500 Turku 20/32 The diagram gives some efficiency data from commercial vapour

Zevenhoven, Ron

314

List of Refrigerators Incentives | Open Energy Information  

Open Energy Info (EERE)

Refrigerators Incentives Refrigerators Incentives Jump to: navigation, search The following contains the list of 657 Refrigerators Incentives. CSV (rows 1-500) CSV (rows 501-657) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial Custom Project Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Fed. Government Industrial Institutional Local Government Nonprofit Schools State Government Tribal Government Boilers Central Air conditioners Chillers Custom/Others pending approval Furnaces Heat pumps Heat recovery Lighting Lighting Controls/Sensors Processing and Manufacturing Equipment Refrigerators Yes AEP Ohio - Commercial Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Fed. Government Industrial

315

Building Technologies Office: Refrigerated Beverage Vending Machines...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Use to Save Money. Learn More. News DOE Issues Notice of Proposed Rulemaking for Commercial Refrigeration Equipment Energy Conservation Standard August 29, 2013 DOE Issues...

316

Regenerator for Magnetic Refrigerants - Energy Innovation Portal  

Magnetic refrigeration is being investigated as an alternative to conventional gas compressor technology ... because of its potential to save energy and ...

317

An Alternative Refrigeration System For Automotive Applications.  

E-Print Network (OSTI)

??The air conditioning systems currently utilized in automobiles are the vapor compression systems. This type of system has many disadvantages: the refrigerant used is not… (more)

McLaughlin, Shannon

2005-01-01T23:59:59.000Z

318

Multi-stage Cascaded Stirling Refrigerator  

NLE Websites -- All DOE Office Websites (Extended Search)

have developed a multi-stage refrigerator, designed to recapture and utilize the acoustic energy that would ordinarily be wasted in traditional Stirling configurations. Available...

319

NIST Quantum Refrigerator Offers Extreme Cooling and ...  

Science Conference Proceedings (OSTI)

... NIST's prototype solid-state refrigerator uses quantum physics in the square chip mounted on the green circuit board to cool the much larger copper ...

2013-03-05T23:59:59.000Z

320

Magnetic Refrigeration a 21 - Programmaster.org  

Science Conference Proceedings (OSTI)

Presentation Title, Magnetic Refrigeration a 21st Century Highly Efficient and Green ... Alloy Design and Powder Processing of Mn-Al Based Materials for Rare

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Technical evaluation of the adequacy of station electric-distribution-system voltages for the Pilgrim Nuclear Power Station, Unit 1  

Science Conference Proceedings (OSTI)

This report documents the technical evaluation of the adequacy of the station electric distribution system voltages for the Pilgrim Nuclear Power Station, Unit 1. The evaluation is to determine if the onsite distribution system in conjunction with the offsite power sources has sufficient capacity to automatically start and operate all Class 1E loads within the equipment voltage ratings under certain conditions established by the Nuclear Regulatory Commission. The analyses demonstrated that for the worst case conditions established, the Class 1E equipment will automatically start and continue to operate within the equiment design voltage rating.

Selan, J.C.

1981-12-28T23:59:59.000Z

322

Development of the severe accident management guidelines (SAMG) for Ulchin Nuclear Power Plant Unit 3, 4, 5 and 6  

SciTech Connect

This paper describes the development process of the severe accident management guidelines (SAMG) for Units 3, 4, 5 and 6 of Ulchin Nuclear Power Plant. The units are Korean Standard Nuclear Power (KSNP) plant, 1000 MWe class pressurized water reactor (PWR) with two loops of primary coolant system. The severe accident management guidelines for the units have been completed in 2002. The generic severe accident management guidance for Korean Standard Nuclear Power Plant has been used as the basis when developing Ulchin severe accident management guideline. Result of probabilistic safety assessment (PSA) for each unit was reviewed to integrate its insight into the SAMG. It indicates that each unit has a balanced design to any specific initiating events for core damage. Seven severe accident management strategies are applied in Ulchin SAMG. Seven strategies are (1) Inject into the steam generator (2) De-pressurize the RCS (3) Inject into the RCS (4) Inject into the containment (5) Control the fission product release into environment (6) Control the containment pressure and temperature and (7) Control hydrogen concentration in the containment. The range and capability of essential instrument for performing the strategies are assessed. Computational aids are developed to complement the unavailable instrument during the accident and to assist the operator's decision choosing strategies. To examine the ability of the SAMG to fulfill its intended function, small loss of coolant accident (SLOCA) with the failure of safety injection was selected as a reference scenario. The scenario was analyzed using MAAP code. The evaluation of the SAMG using this sequence has been successfully completed. (authors)

Kim, Hyeong T.; Yoo, Hojong; Lim, Hyuk Soon; Park, Jong W.; Lim, Woosang; Oh, Seung Jong [Korea Hydro and Nuclear Power Co., Ltd., 103-16 Munji-Dong, Yusung-Gu, Daejeon, 305-380 (Korea, Republic of); Chung, Chang Hyun [Seoul National University (Korea, Republic of); Lee, Byung Chul [Future and Challenges, Inc (Korea, Republic of)

2004-07-01T23:59:59.000Z

323

Robust Controller Design for Simultaneous Control of Throttle Pressure and Megawatt Output in a Power Plant Unit  

Science Conference Proceedings (OSTI)

Recently proposed (( and (-synthesis controller design methodologies permit the design of high-performance control systems for plants that are difficult to model accurately. The work summarized in this report assesses the benefits of the (( and (-synthesis controllers for the simultaneous control of throttle pressure and megawatt output in a power plant unit, while also serving to clarify the (( and (-synthesis design methods by an example.

1999-02-25T23:59:59.000Z

324

Federal Energy Management Program: Covered Product Category: Refrigerated  

NLE Websites -- All DOE Office Websites (Extended Search)

Refrigerated Beverage Vending Machines to someone by E-mail Refrigerated Beverage Vending Machines to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Google Bookmark Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Delicious Rank Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on AddThis.com...

325

DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements March 16, 2010 - 4:28pm...

326

Thermal Analysis of Refrigeration Systems Used for Vaccine ...  

Science Conference Proceedings (OSTI)

... style refrigerator and a freezerless household refrigerator used ... possible that the nature of the cooling system and ... model simply do not cool the side ...

2012-08-02T23:59:59.000Z

327

Air-Conditioning, Heating, and Refrigeration Institute (AHRI...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI These comments...

328

U.S. Residential Miscellaneous Refrigeration Products: Results...  

NLE Websites -- All DOE Office Websites (Extended Search)

Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys Title U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon...

329

COMPUTER DESIGN AND OPTIMIZATION OF CRYOGENIC REFRIGERATION SYSTEMS  

E-Print Network (OSTI)

be used to design and optimize refrigeration cycles as wellCOMPUTER DESIGN AND OPTIMIZATION OF CRYOGENIC REFRIGERATIONTrial Design Fixed state parameters (bar) Refrigeration

green, M.A.

2011-01-01T23:59:59.000Z

330

China Refrigerator Information Label: Specification Development and Potential Impact  

E-Print Network (OSTI)

ERKELEY N ATIONAL L ABORATORY China Refrigerator InformationDivision Jianhong Cheng China National Institute of7 Table 2 Coefficient Values for China Refrigerator 2003

Fridley, David

2008-01-01T23:59:59.000Z

331

Disparities in nuclear power plant performance in the United States and the Federal Republic of Germany  

E-Print Network (OSTI)

This report presents data comparing the performance of light water reactors in the United States and the Federal Republic of Germany (FRG). The comparisons are made for the years 1980-1983 and include 21 Westinghouse ...

Hansen, Kent F.

1984-01-01T23:59:59.000Z

332

Community wind power ownership schemes in Europe and their relevance to the United States  

E-Print Network (OSTI)

an overview of commercial wind farm financing in the Unitedthe United States, where wind farms tend to be quite largeworld’s largest offshore wind farm to date – a 40 MW project

Bolinger, Mark

2001-01-01T23:59:59.000Z

333

Characterization of Wind Power Resource in the United States and its Intermittency  

E-Print Network (OSTI)

Wind resource in the continental and offshore United States has been reconstructed and characterized using metrics that describe, apart from abundance, its availability, persistence and intermittency. The Modern Era ...

Gunturu, U.B.

334

PureComfort 240 Combined Cooling,Heating,and Power Unit  

Science Conference Proceedings (OSTI)

This report is the second interim case study of a PureComfort 240 combined cooling, heating and power project at the University of Toronto, Mississauga.

2006-12-06T23:59:59.000Z

335

Trends of Wind and Wind Power Over the Coterminous United States.  

E-Print Network (OSTI)

??The trends of wind and wind power at a typical wind turbine hub height (80 m) are analyzed using the North American Regional Reanalysis (NARR)… (more)

Holt, Eric M

2011-01-01T23:59:59.000Z

336

Supporting Solar Power in Renewables Portfolio Standards: Experience from the United States  

E-Print Network (OSTI)

and CSP Projects ..of the concentrating solar power (CSP) market in the U.S.1980’s, construction of CSP capacity in the U.S. largely

Wiser, Ryan

2010-01-01T23:59:59.000Z

337

Transformer failure and common-mode loss of instrument power at Nine Mile Point Unit 2 on August 13, 1991  

Science Conference Proceedings (OSTI)

On August 13, 1991, at Nine Mile Point Unit 2 nuclear power plant, located near Scriba, New York, on Lake Ontario, the main transformer experienced an internal failure that resulted in degraded voltage which caused the simultaneous loss of five uninterruptible power supplies, which in turn caused the loss of several nonsafety systems, including reactor control rod position indication, some reactor power and water indication, control room annunciators, the plant communications system, the plant process computer, and lighting at some locations. The reactor was subsequently brought to a safe shutdown. Following this event, the US Nuclear Regulatory Commission dispatched an Incident Investigation Team to the site to determine what happened, to identify the probable causes, and to make appropriate findings and conclusions. This report describes the incident, the methodology used by the team in its investigation, and presents and the team's findings and conclusions. 59 figs., 14 tabs.

Not Available

1991-10-01T23:59:59.000Z

338

U.S. Job Creation Due to Nuclear Power Resurgence in The United States — Volumes 1 and 2  

SciTech Connect

The recent revival of interest in nuclear power is causing a reexamination of the role of nuclear power in the United States. This renewed interest has led to questions regarding the capability and capacity of current U.S. industries to support a renewal of nuclear power plant deployment. This study was conducted to provide an initial estimate of jobs to be gained in the U.S. through the repatriation of the nuclear manufacturing industry. In the course of the study, related job categories were also modeled to provide an additional estimate of the potential expansion of existing industries (i.e., plant construction and operations) in conjunction with the repatriation of manufacturing jobs.

Catherine M. Plowman

2004-11-01T23:59:59.000Z

339

Date | 1Refrigeration and Air Conditioning EMA Education and Training Date | 2Refrigeration and Air Conditioning EMA Education and Training  

E-Print Network (OSTI)

Date | 1Refrigeration and Air Conditioning EMA Education and Training #12;Date | 2Refrigeration Flow Coil Design etc. Finger Print Relationship Every evaporator is unique Unstable Region * = examples

Oak Ridge National Laboratory

340

Cost of Power Interruptions to Electricity Consumers in the UnitedStates (U.S.)  

SciTech Connect

The massive electric power blackout in the northeastern U.S.and Canada on August 14-15, 2003 catalyzed discussions about modernizingthe U.S. electricity grid. Industry sources suggested that investments of$50 to $100 billion would be needed. This work seeks to better understandan important piece of information that has been missing from thesediscussions: What do power interruptions and fluctuations in powerquality (power-quality events) cost electricity consumers? We developed abottom-up approach for assessing the cost to U.S. electricity consumersof power interruptions and power-quality events (referred to collectivelyas "reliability events"). The approach can be used to help assess thepotential benefits of investments in improving the reliability of thegrid. We developed a new estimate based on publicly availableinformation, and assessed how uncertainties in these data affect thisestimate using sensitivity analysis.

Hamachi LaCommare, Kristina; Eto, Joseph H.

2006-02-16T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Seven-effect absorption refrigeration  

DOE Patents (OSTI)

A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit.

DeVault, Robert C. (Knoxville, TN); Biermann, Wendell J. (Fayetteville, NY)

1989-01-01T23:59:59.000Z

342

Seven-effect absorption refrigeration  

DOE Patents (OSTI)

A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit. 1 fig.

DeVault, R.C.; Biermann, W.J.

1989-05-09T23:59:59.000Z

343

Compatibility of refrigerants and lubricants with elastomers  

Science Conference Proceedings (OSTI)

The information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on availability of additional R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1993-01-01T23:59:59.000Z

344

Compatibility of refrigerants and lubricants with elastomers  

Science Conference Proceedings (OSTI)

Information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on the availability of additional quantities of R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 hours and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1992-10-01T23:59:59.000Z

345

Correlation Between Geographically Dispersed Concentrating Solar Power and Demand in the United States  

Science Conference Proceedings (OSTI)

Correlations between the electricity generated by concentrating solar thermal power (CSP) plants, as well as cross-correlations between CSP, wind power and electricity demand, have significant impacts on decisions for how much and where to build utility-scale CSP capacity, the optimal amount of thermal storage in the CSP plants, reserve capacity needed to back-up the system, as well as the expected levels of curtailed renewable power. Accurately estimating these correlations is vital to performing detailed analyses of high renewable penetration scenarios. This study quantifies the degree of correlation between geographically dispersed CSP, as well as the correlation between CSP and wind power, and CSP and electricity demand in 356 discrete regions in the contiguous US. Correlations are calculated using hourly data on an annual basis. Maps of the correlations will be presented to illustrate the degree of correlation between solar power and the demand it is serving, as well as the synergies between the negatively-correlated wind power and solar power serving the same region.

Mowers, M.; Helm, C.; Blair, N.; Short, W.

2010-01-01T23:59:59.000Z

346

Otter Tail Power Company - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Energy Efficiency Rebate Residential Energy Efficiency Rebate Program Otter Tail Power Company - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Heat Pumps Appliances & Electronics Commercial Lighting Lighting Water Heating Maximum Rebate Refrigeration/Cooking/Lighting: rebate will not exceed 75% of project cost Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Water Heaters: $150 - $300 Thermal Storage Units: $20 - $40/KW Insulation: up to $300 Refrigerator Recycling: $50 Air-Source Heat Pumps: $240/ton Geothermal Heat Pumps: $600/ton Lighting: In-store discount Provider Customer Service Otter Tail Power Company Rebate Program offers rebates to qualifying

347

Damodar Valley Corporation, Chandrapura Unit 2 Thermal Power Station Residual Life Assessment Summary report  

Science Conference Proceedings (OSTI)

The BHEL/NTPC/PFC/TVA teams assembled at the DVC`s Chadrapura station on July 19, 1994, to assess the remaining life of Unit 2. The workscope was expanded to include major plant systems that impact the unit`s ability to sustain generation at 140 MW (Units 1-3 have operated at average rating of about 90 MW). Assessment was completed Aug. 19, 1994. Boiler pressure parts are in excellent condition except for damage to primary superheater header/stub tubes and economizer inlet header stub tubes. The turbine steam path is in good condition except for damage to LP blading; the spar rotor steam path is in better condition and is recommended for Unit 2. Nozzle box struts are severely cracked from the flame outs; the cracks should not be repaired. HP/IP rotor has surface cracks at several places along the steam seal areas; these cracks are shallow and should be machined out. Detailed component damage assessments for above damaged components have been done. The turbine auxiliary systems have been evaluated; cooling tower fouling/blockage is the root cause for the high turbine back pressure. The fuel processing system is one of the primary root causes for limiting unit capacity. The main steam and hot reheat piping systems were conservatively designed and have at least 30 years left;deficiencies needing resolution include restoration of insulation, replacement of 6 deformed hanger clamp/bolts, and adjustment of a few hanger settings. The cold reheat piping system is generally in good condition; some areas should be re-insulated and the rigid support clamps/bolts should be examined. The turbine extraction piping system supports all appeared to be functioning normally.

NONE

1995-02-01T23:59:59.000Z

348

Experimental and cost analyses of a one kilowatt-hour/day domestic refrigerator-freezer  

SciTech Connect

Over the past ten years, government regulations for energy standards, coupled with the utility industry`s promotion of energy-efficient appliances, have prompted appliance manufacturers to reduce energy consumption in refrigerator-freezers by approximately 40%. Global concerns over ozone depletion have also required the appliance industry to eliminate CFC-12 and CFC-11 while concurrently improving energy efficiency to reduce greenhouse emissions. In response to expected future regulations that will be more stringent, several design options were investigated for improving the energy efficiency of a conventionally designed, domestic refrigerator-freezer. The options, such as cabinet and door insulation improvements and a high-efficiency compressor were incorporated into a prototype refrigerator-freezer cabinet and refrigeration system. Baseline energy consumption of the original 1996 production refrigerator-freezer, along with cabinet heat load and compressor calorimeter test results, were extensively documented to provide a firm basis for experimentally measured energy savings. The goal for the project was to achieve an energy consumption that is 50% below in 1993 National Appliance Energy Conservation Act (NAECA) standard for 20 ft{sup 3} (570 l) units. Based on discussions with manufacturers to determine the most promising energy-saving options, a laboratory prototype was fabricated and tested to experimentally verify the energy consumption of a unit with vacuum insulation around the freezer, increased door thicknesses, a high-efficiency compressor, a low wattage condenser fan, a larger counterflow evaporator, and adaptive defrost control.

Vineyard, E.A.; Sand, J.R.

1997-05-01T23:59:59.000Z

349

A comparative analysis of business structures suitable forfarmer-owned wind power projects in the United States  

DOE Green Energy (OSTI)

For years, farmers in the United States have looked with envy on their European counterparts' ability to profitably farm the wind through ownership of distributed, utility-scale wind projects. Only within the past few years, however, has farmer- or community-owned wind power development become a reality in the United States. The primary hurdle to this type of development in the United States has been devising and implementing suitable business and legal structures that enable such projects to take advantage of tax-based federal incentives for wind power. This article discusses the limitations of such incentives in supporting farmer- or community-owned wind projects, describes four ownership structures that potentially overcome such limitations, and finally conducts comparative financial analysis on those four structures, using as an example a hypothetical 1.5 MW farmer-owned project located in the state of Oregon. We find that material differences in the competitiveness of each structure do exist, but that choosing the best structure for a given project will largely depend on the conditions at hand; e.g., the ability of the farmer(s) to utilize tax credits, preference for individual versus ''cooperative'' ownership, and the state and utility service territory in which the project will be located.

Bolinger, Mark; Wiser, Ryan

2004-11-11T23:59:59.000Z

350

Cost of Power Interruptions to Electricity Consumers in the United States (U.S.)  

E-Print Network (OSTI)

ever power-quality- cost estimate of $26 billion per yearcovers. Typically, outage-cost estimates are based on whatof uncertainty in the cost estimates that have been prepared

Hamachi LaCommare, Kristina; Eto, Joseph H.

2006-01-01T23:59:59.000Z

351

Potential Role of Concentrating Solar Power in Enabling High Renewables Scenarios in the United States  

Science Conference Proceedings (OSTI)

This work describes the analysis of concentrating solar power (CSP) in two studies -- The SunShot Vision Study and the Renewable Electricity Futures Study -- and the potential role of CSP in a future energy mix.

Denholm, P.; Hand, M.; Mai, T.; Margolis, R.; Brinkman, G.; Drury, E.; Mowers, M.; Turchi, C.

2012-10-01T23:59:59.000Z

352

SRP - PowerWise Business Solutions Energy Efficiency Rebate Program...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ton, depending on efficiency of the installed unit VFDs: 55 per hp on controlled HVAC fan and pump motors Refrigeration Measures: Varies widely by application ECM Motors...

353

Optimal Performance of Quantum Refrigerators  

E-Print Network (OSTI)

A reciprocating quantum refrigerator is studied with the purpose of determining the limitations of cooling to absolute zero. We find that if the energy spectrum of the working medium possesses an uncontrollable gap, then there is a minimum achievable temperature above zero. Such a gap, combined with a negligible amount of noise, prevents adiabatic following during the demagnetization stage which is the necessary condition for reaching $T_c \\to 0$. The refrigerator is based on an Otto cycle where the working medium is an interacting spin system with an energy gap. For this system the external control Hamiltonian does not commute with the internal interaction. As a result during the demagnetization and magnetization segments of the operating cycle the system cannot follow adiabatically the temporal change in the energy levels. We connect the nonadiabatic dynamics to quantum friction. An adiabatic measure is defined characterizing the rate of change of the Hamiltonian. Closed form solutions are found for a constant adiabatic measure for all the cycle segments. We have identified a family of quantized frictionless cycles with increasing cycle times. These cycles minimize the entropy production. Such frictionless cycles are able to cool to $T_c=0$. External noise on the controls eliminates these frictionless cycles. The influence of phase and amplitude noise on the demagnetization and magnetization segments is explicitly derived. An extensive numerical study of optimal cooling cycles was carried out which showed that at sufficiently low temperature the noise always dominates restricting the minimum temperature.

Tova Feldmann; Ronnie Kosloff

2009-06-04T23:59:59.000Z

354

Oil cooled, hermetic refrigerant compressor  

DOE Patents (OSTI)

A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler and is then delivered through the shell to the top of the motor rotor where most of it is flung radially outwardly within the confined space provided by the cap which channels the flow of most of the oil around the top of the stator and then out to a multiplicity of holes to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator from which the suction gas passes by a confined path in pipe to the suction plenum and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum. 3 figs.

English, W.A.; Young, R.R.

1985-05-14T23:59:59.000Z

355

Oil cooled, hermetic refrigerant compressor  

DOE Patents (OSTI)

A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler 18 and is then delivered through the shell to the top of the motor rotor 24 where most of it is flung radially outwardly within the confined space provided by the cap 50 which channels the flow of most of the oil around the top of the stator 26 and then out to a multiplicity of holes 52 to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber 58 to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole 62 also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator 68 from which the suction gas passes by a confined path in pipe 66 to the suction plenum 64 and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum 64.

English, William A. (Murrysville, PA); Young, Robert R. (Murrysville, PA)

1985-01-01T23:59:59.000Z

356

Novel materials for laser refrigeration  

SciTech Connect

The status of optical refrigeration of rare-earth-doped solids is reviewed, and the various factors that limit the performance of current laser-cooling materials are discussed. Efficient optical refrigeration is possible in materials for which {Dirac_h}{omega}{sub max} < E{sub p}/8, where {Dirac_h}{omega}{sub max} is the maximum phonon energy of the host material and E{sub p} is the pump energy of the rare-earth dopant. Transition-metal and OH{sup -}impurities at levels >100 ppb are believed to be the main factors for the limited laser-cooling performance in current materials. The many components of doped ZBLAN glass pose particular processing challenges. Binary fluoride glasses such as YF{sub 3}-LiF are considered as alternatives to ZBLAN. The crystalline system KPb{sub 2}CI{sub 5} :Dy{sup 3+} is identified as a prime candidate for high-efficiency laser cooling.

Hehlen, Markus P [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

357

Feasibility study of units 3 and 4. Batlle y Ordonez Power Station and expansion of La Tablada Power Station. Export trade information  

SciTech Connect

The study, conducted by Southern Electric International (SEI), was funded by the U.S. Trade and Development Agency on behalf of U.T.E., the Government of Uruguay's electric power company. It is an assessment of three potential projects under consideration by U.T.E. The changes resulting from these projects would add 120 to 360 megawatts capacity to the current system. The first option would involve repowering Jose Batlle y Ordonex Units 3 and 4. As an alternate to this plan, U.T.E. is considering a new combined cycle plant at a Greenfield site. The third project would increase capacity at La Tablada.

Not Available

1994-01-21T23:59:59.000Z

358

RADIOISOTOPE FUELED AUXILIARY POWER UNIT. Quarterly Progress Report No. 7, July-September 1958  

SciTech Connect

Progress made in the development of SNAP-1 and -3 is reported. SNAP-1 development reported includes: boiler development, fuel development, properties of cerium dioxide, materials corrosion, power conversion system development, shielding analysis, hazards evaluation, and ground test development. SNAP-3 development includes: power conversion analysis, thermoelectric generator development, and fuel element development. Information is given on the handling and transportation equipment for SNAP-1. (N.W.R.)

1963-10-31T23:59:59.000Z

359

Solar powered automatic turn-on control (spa-toc) unit and method  

SciTech Connect

Orderly control of power applied by a photovoltaic solar panel d.c. source to a load is attained despite varying long and short term solar conditions by coupling power from the panel to an inverter in response to the panel voltage exceeding a predetermined level and preventing coupling of power from the panel to the inverter in response to the panel voltage being less than a predetermined level. The switching frequency of the inverter is controlled in response to the panel voltage so that approximately maximum power which the panel is capable of generating is supplied to the inverter for the incident solar energy on the panel at a given temperature. Power is supplied to the inverter by a series switch between the panel and inverter. The switch is activated into a conducting state in response to the panel voltage exceeding a predetermined value. The panel voltage controls the turn-on and turn-off levels of the series switch by a hysteresis effect, provided by connecting a dummy power dissipating load in shunt with the panel while the series switch is cut off. The dummy load has a value causing the panel output voltage to be less than the voltage for maximum panel output power. A similar series switch and hysteresis control is provided for control circuitry for the inverter. The series switch for supplying power to the control circuitry can be activated in response to the same voltage which activates the series switch for the inverter, or in response to a different voltage level.

Baker, R.H.

1982-06-01T23:59:59.000Z

360

Component Failure and Repair Data for Coal-Fired Power Units  

Science Conference Proceedings (OSTI)

A complete and consistent set of failure rate and time-to-restore data for components of a coal-fired generating unit was developed for use in the validation of a reliability and availability assessment model. This report presents the data and describes the principal methodology used--a failure modes analysis. It also includes process flow diagrams.

1981-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Z .Decision Support Systems 24 1999 297310 A transmission-constrained unit commitment method in power  

E-Print Network (OSTI)

Ã?ersity of California, Berkeley, CA 94720, USA b Pacific Gas Electric Company, San Francisco, CA 94177, USA Abstract. The transmission constraints, as well as the demand and spinning reserve constraints, are relaxed by attaching generating units over a short-term planning horizon subject to the satisfaction of demand and other system

Oren, Shmuel S.

362

Carbon Dioxide Emissions from the Generation of Electric Power in the United States 1998  

Reports and Publications (EIA)

The President issued a directive on April 15, 1999, requiring an annual report summarizing carbon dioxide (CO2) emissions produced by electricity generation in the United States, including both utilities and nonutilities. In response, this report is jointly submitted by the U.S. Department of Energy and the U.S. Environmental Protection Agency.

Information Center

1999-10-15T23:59:59.000Z

363

Design of heat-recovery and seed-recovery units in MHD power generation  

DOE Green Energy (OSTI)

Crucial and limiting engineering and materials problems associated with the design of an MHD steam bottoming plant are discussed. Existing experimental and theoretical results on corrosion, fouling and deposits, potassium seed recovery and regeneration, are reviewed. The state of knowledge regarding the design of heat recovery and seed recovery units for coal-fired MHD plants is inadequate at the present time.

Bergman, P.D.; Joubert, J.I.; Demski, R.J.; Bienstock, D.

1974-01-01T23:59:59.000Z

364

Near-term implications of a ban on new coal-fired power plants in the United States  

Science Conference Proceedings (OSTI)

Large numbers of proposed new coal power generators in the United States have been cancelled, and some states have prohibited new coal power generators. We examine the effects on the U.S. electric power system of banning the construction of coal-fired electricity generators, which has been proposed as a means to reduce U.S. CO{sub 2} emissions. The model simulates load growth, resource planning, and economic dispatch of the Midwest Independent Transmission System Operator (ISO), Inc., Electric Reliability Council of Texas (ERCOT), and PJM under a ban on new coal generation and uses an economic dispatch model to calculate the resulting changes in dispatch order, CO{sub 2} emissions, and fuel use under three near-term (until 2030) future electric power sector scenarios. A national ban on new coal-fired power plants does not lead to CO{sub 2} reductions of the scale required under proposed federal legislation such as Lieberman-Warner but would greatly increase the fraction of time when natural gas sets the price of electricity, even with aggressive wind and demand response policies. 50 refs., 5 figs., 4 tabs.

Adam Newcomer; Jay Apt [Carnegie Mellon University, Pittsburgh, PA (United States). Carnegie Mellon Electricity Industry Center

2009-06-15T23:59:59.000Z

365

Wind Power Price Trends in the United States: Struggling to Remain Competitive in the Face of Strong Growth  

SciTech Connect

The amount of wind power capacity being installed globally is surging, with the United States the world leader in terms of annual market share for three years running (2005-2007). The rapidly growing market for wind has been a double-edged sword, however, as the resulting supply-demand imbalance in wind turbines, along with the rising cost of materials and weakness in the U.S. dollar, has put upward pressure on wind turbine costs, and ultimately, wind power prices. Two mitigating factors--reductions in the cost of equity provided to wind projects and improvements in project-level capacity factors--have helped to relieve some of the upward pressure on wind power prices over the last few years. Because neither of these two factors can be relied upon to further cushion the blow going forward, policymakers should recognize that continued financial support may be necessary to sustain the wind sector at its current pace of development, at least in the near term. Though this article emphasizes developments in the U.S. market for wind power, those trends are similar to, and hold implications for, the worldwide wind power market.

Bolinger, Mark A; Wiser, Ryan

2008-10-30T23:59:59.000Z

366

LIFAC Demonstration at Richmond Power and Light Whitewater Valley Unit No. 2 Volume II: Project Performance and Economics  

SciTech Connect

The C1ean Coal Technology (CCT) Program has been recognized in the National Energy Strategy as a major initiative whereby coal will be able to reach its full potential as a source of energy for the nation and the international marketplace. Attainment of this goal depends upon the development of highly efficient, environmentally sound, competitive coal utilization technologies responsive to diverse energy markets and varied consumer needs. The CCT Program is an effort jointly funded by government and industry whereby the most promising of the advanced coal-based technologies are being moved into the marketplace through demonstration. The CCT Program is being implemented through a total of five competitive solicitations. LIFAC North America, a joint venture partnership of ICF Kaiser Engineers, Inc., and Tampella Power Corporation, is currently demonstrating the LIFAC flue gas desulfurization technology developed by Tampella Power. This technology provides sulfur dioxide emission control for power plants, especially existing facilities with tight space limitations. Sulfur dioxide emissions are expected to be reduced by up to 85% by using limestone as a sorbent. The LIFAC technology is being demonstrated at Whitewater Valley Unit No. 2, a 60-MW coal-fired power plant owned and operated by Richmond Power and Light (RP&L) and located in Richmond, Indiana. The Whitewater plant consumes high-sulfur coals, with sulfur contents ranging from 2.0-2.9 $ZO. The project, co-funded by LIFAC North America and DOE, is being conducted with the participation of Richmond Power and Light, the State of Indiana, the Electric Power Research Institute (EPRI), and the Black Beauty Coal Company. The project has a total cost of $21.4 million and a duration of 48 months from the preliminary design phase through the testing program.

None

1998-04-01T23:59:59.000Z

367

Bubble Pump Design for Single Pressure Absorption Refrigeration Cycles  

E-Print Network (OSTI)

A model has been developed for the design and optimization of a small bubble pump to be used in a single pressure absorption refrigeration cycle to lift the working fluid mixture against gravity and overcome flow friction. This analytical model is developed from two-phase flow fundamentals and incorporates the design parameters of the bubble pump. Parametric studies are carried out and a design optimization for maximum efficiency is performed for various operating conditions. Optimum efficiency is defined as the liquid pumped per unit of bubble pump heat input. The results show the optimum bubble pump tube diameter over a range of operating conditions.

Sam V. Shelton; Susan White Stewart

2002-01-01T23:59:59.000Z

368

Magnetic Refrigeration Technology for High Efficiency Air Conditioning  

SciTech Connect

Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate heat exchangers or oil distribution issues found in traditional vapor compression systems.

Boeder, A; Zimm, C

2006-09-30T23:59:59.000Z

369

REQUEST BY UNITED TECHNOLOGIES RESEARCH CENTER, FOR AN ADVANCE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SUBCONTRACT NO. 4000009518 UNDER DOE SUBCONTRACT NO. 4000009518 UNDER DOE PRIME CONTRACT NO. DE-AC05-00OR22725; DOE WAIVER DOCKET W(A)-01- 026 [ORO-766] Petitioner, United Technologies Research Center, has made a timely request for an advance waiver to worldwide rights in Subject Inventions made in the course of or under Subcontract No 4000009518 under DOE Prime Contract No. DE-AC05-00OR22725. The scope of this work is to develop a building combined heat and power (BCHP) system. In a BCHP, microturbines, high temperature fuel cells, and combinations of each produce electric power at the site while exhaust gas from the power plants is utilized to produce cooling, refrigeration, space heating, hot water and dehumidification for the building. This work is sponsored by the Office of Distributed Energy Resources, Office of Power Technologies.

370

Review of Alternate Hydrazine Injection Data: South Texas Project Power Station -- Unit 1  

Science Conference Proceedings (OSTI)

This report reviews South Texas Project Unit 1 chemistry data collected before, during, and after alternate hydrazine injections in 1999. Normally, hydrazine is injected into the condensate system just after the condensate polishers, but during alternate hydrazine injection periods, hydrazine was fed into the feedwater system just after the last feedwater heater. The main objective of these injections was to reduce feedwater iron concentrations; additionally, their effect on several chemistry parameters ...

2001-06-11T23:59:59.000Z

371

Dual-circuit, multiple-effect refrigeration system and method  

DOE Patents (OSTI)

A dual circuit absorption refrigeration system comprising a high temperature single-effect refrigeration loop and a lower temperature double-effect refrigeration loop separate from one another and provided with a double-condenser coupling therebetween. The high temperature condenser of the single-effect refrigeration loop is double coupled to both of the generators in the double-effect refrigeration loop to improve internal heat recovery and a heat and mass transfer additive such as 2-ethyl-1-hexanol is used in the lower temperature double-effect refrigeration loop to improve the performance of the absorber in the double-effect refrigeration loop.

DeVault, Robert C. (Knoxville, TN)

1995-01-01T23:59:59.000Z

372

Surgut steam power plant: Block 1, unit 1 reconstruction feasibility study. Volume 2. Export trade information  

Science Conference Proceedings (OSTI)

Project Description; Work Tasks: Review Plant Data; Power Cycle, Heat Balance Study; Heat Cycle Screening and Selection; Selected Heat Cycle Discussion; Heat Balance Summary Data and Diagram; Plant Conceptual Engineering; Major Mechanical System Descriptions; Main, Reheat, District Heating Steam Systems; Feedwater and Condensate System; HRSG Blowdown System; Chemical Feed System; Auxiliary Cooling System; Natural Gas Fuel System; Piping System; and Flue Gas System.

Not Available

1993-11-24T23:59:59.000Z

373

HE ELECTRIC POWER INDUSTRY in the United States is facing a disquieting shortage  

E-Print Network (OSTI)

. "The power industry--both utilities and manufacturers--hires bright people [with college degrees] who & manufacturing technology 88 850 7 Signals & applications 87 000 8 Antennas & propagation 86 000 9 Signal of electric and hybrid vehicles. These activities are, in turn, leading to lecture top- ics and lab exercises

374

Establishing a Groundwater Protection Program for New Nuclear Generating Units: Appendix to the EPRI Groundwater Protection Guidelines for Nuclear Power Plants  

Science Conference Proceedings (OSTI)

New nuclear power plants should plan for groundwater protection early in the planning process. The construction project team should be made aware of the need to establish the groundwater protection program prior to the construction planning process. This document provides guidance for establishing Groundwater Protection Programs for new nuclear generating units. It applies to new nuclear generating units on both new and existing nuclear power plant ...

2013-03-27T23:59:59.000Z

375

Bearing construction for refrigeration compresssor  

DOE Patents (OSTI)

A hermetic refrigeration compressor has a cylinder block and a crankshaft rotatable about a vertical axis to reciprocate a piston in a cylinder on the cylinder block. A separate bearing housing is secured to the central portion of the cylinder block and extends vertically along the crankshaft, where it carries a pair of roller bearings to journal the crankshaft. The crankshaft has a radially extending flange which is journaled by a thrust-type roller bearing above the bearing housing to absorb the vertical forces on the crankshaft so that all three of the roller bearings are between the crankshaft and the bearing housing to maintain and control the close tolerances required by such bearings.

Middleton, Marc G. (Wyoming, MI); Nelson, Richard T. (Worthington, OH)

1988-01-01T23:59:59.000Z

376

Optimization of Industrial Refrigeration Systems  

E-Print Network (OSTI)

A computer program designed to optimize the size of an evaporative condenser in a two-stage industrial refrigeration plant was created. The program sizes both the high-stage and low-stage compressors and an evaporative condenser. Once the initial system is sized, a year long plant simulation is performed resulting in electric energy consumption profile and an exergy destruction profile for each component and for the system. The program uses actual regional hourly outside dry bulb and wet bulb temperatures for both sizing and simulation. An exergoeconomic optimization uses the results of the simulation combined with component and energy costs to optimize the condenser size such that both plant costs and energy losses are minimized.

Flack, P. J.; Sharp, M. K.; Case, M. E.; Gregory, R. W.; Case, P. L.

1995-04-01T23:59:59.000Z

377

Algorithm for Screening Phasor Measurement Unit Data for Power System Events and Categories and Common Characteristics for Events Seen in Phasor Measurement Unit Relative Phase-Angle Differences and Frequency Signals  

SciTech Connect

A network of multiple phasor measurement units (PMU) was created, set up, and maintained at the University of Texas at Austin to obtain actual power system measurements for power system analysis. Power system analysis in this report covers a variety of time ranges, such as short- term analysis for power system disturbances and their effects on power system behavior and long- term power system behavior using modal analysis. The first objective of this report is to screen the PMU data for events. The second objective of the report is to identify and describe common characteristics extracted from power system events as measured by PMUs. The numerical characteristics for each category and how these characteristics are used to create selection rules for the algorithm are also described. Trends in PMU data related to different levels and fluctuations in wind power output are also examined.

Allen, A.; Santoso, S.; Muljadi, E.

2013-08-01T23:59:59.000Z

378

The evolution of NOx control policy for coal-fired power plants in the United States  

Science Conference Proceedings (OSTI)

Emissions of nitrogen oxides (NOx) contribute to formation of particulate matter and ozone, and also to acidification of the environment. The electricity sector is responsible for about 20% of NOx emissions in the United States, and the sector has been the target of both prescriptive (command-and-control) and flexible (cap-and-trade) approaches to regulation. The paper summarises the major NOx control policies affecting this sector in the USA, and provides some perspectives as to their effectiveness. While both prescriptive and flexible approaches continue to play an important role, significant new proposals have wholly embraced a cap-and-trade approach. 20 refs., 7 figs., 2 tabs.

Dallas Burtraw; David A. Evans

2003-12-15T23:59:59.000Z

379

Status of not-in-kind refrigeration technologies for household space conditioning, water heating and food refrigeration  

Science Conference Proceedings (OSTI)

This paper presents a review of the next generation not-in-kind technologies to replace conventional vapor compression refrigeration technology for household applications. Such technologies are sought to provide energy savings or other environmental benefits for space conditioning, water heating and refrigeration for domestic use. These alternative technologies include: thermoacoustic refrigeration, thermoelectric refrigeration, thermotunneling, magnetic refrigeration, Stirling cycle refrigeration, pulse tube refrigeration, Malone cycle refrigeration, absorption refrigeration, adsorption refrigeration, and compressor driven metal hydride heat pumps. Furthermore, heat pump water heating and integrated heat pump systems are also discussed due to their significant energy saving potential for water heating and space conditioning in households. The paper provides a snapshot of the future R&D needs for each of the technologies along with the associated barriers. Both thermoelectric and magnetic technologies look relatively attractive due to recent developments in the materials and prototypes being manufactured.

Bansal, Pradeep [ORNL; Vineyard, Edward Allan [ORNL; Abdelaziz, Omar [ORNL

2012-01-01T23:59:59.000Z

380

Wind Power Development in the United States: Current Progress, Future Trends  

SciTech Connect

The U.S. wind power industry is in an era of substantial growth, with the U.S. and China likely to vie for largest-market status for years to come. With the market evolving at such a rapid pace, keeping up with current trends in the marketplace has become increasingly difficult. At the same time, limits to future growth are uncertain. This paper summarizes major trends in the U.S. wind market, and explores the technical and economic feasibility of achieving much greater levels of wind penetration. China would be well served to conduct similar analyses of the feasibility, benefits, challenges, and policy needs associated with much higher levels of wind power generation than currently expressed in national targets.

Wiser, Ryan H

2008-10-29T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

The Los Alamos 600 MJ, 1500 MW inertial energy storage and pulsed power unit  

DOE Green Energy (OSTI)

A 1430 MVA synchronous generator from a cancelled nuclear power plant has been installed and commissioned at Los Alamos National Laboratory (LANL) to be used as the pulsed power generator for physics experiments. The generator is mounted on a spring foundation to prevent dynamic forces from being transmitted to the substructure and into the ground. A 6 MW load-commutated inverter drive accelerates the machine from standstill to the maximum operating speed of 1800 rpm and from 1260 rpm to 1800 rpm between load pulses. The generator cooling method has been changed from hydrogen to air cooling to facilitate operation. A current limiting fuse, with a fuse clearing current of 90 kA, will protect the generator output against short circuit currents. An overview of the installation is presented. The paper also addresses the overload capability of the generator for pulsed loads. 7 figs., 1 tab.

Boenig, H.J.

1991-01-01T23:59:59.000Z

382

Future Intelligent Power Grids: Analysis of the vision in the European Union and the United States  

Science Conference Proceedings (OSTI)

The future of power grids is expected to involve an increasing level of intelligence and integration of new information and communication technologies in every aspect of the electricity system, from demand-side devices to wide-scale distributed generation to a variety of energy markets. This paper provides a general outlook of the definition of this future in the U.S. and the European Union and compares two approaches—GridWiseTM and SmartGrid. It describes the contexts in both the worlds, as they influence the two visions of the future intelligent power grid, and as they form foundations at each respective federal level for supporting research in this field. The similarities and complementarities of the two research programs are examined. Within the framework of a solid precedence for trans-Atlantic cooperation in energy research, the time would seem optimal to set in motion active collaboration and educational exchange on GridWise and SmartGrid research. This paper will help energy policy makers to better understand the key issues determining the two different approaches and the two different policies derived from them; as well as a comparison of the solution provided in each case. This work will also be useful for researchers and industry decision makers to be aware of trans-Atlantic approaches, opportunities, and resources looking toward future, more intelligent and interconnected power grids.

Coll-Mayor, Debora; Paget, Mia L.; Lightner, Eric M.

2007-04-01T23:59:59.000Z

383

Scaling and Optimization of Magnetic Refrigeration for Commercial Building HVAC Systems Greater than 175 kW in Capacity  

Science Conference Proceedings (OSTI)

Heating, ventilation, air-conditioning and refrigeration (HVACR) account for approximately one- third of building energy consumption. Magnetic refrigeration presents an opportunity for significant energy savings and emissions reduction for serving the building heating, cooling, and refrigeration loads. In this paper, we have examined the magnet and MCE material requirements for scaling magnetic refrigeration systems for commercial building cooling applications. Scaling relationships governing the resources required for magnetic refrigeration systems have been developed. As system refrigeration capacity increases, the use of superconducting magnet systems becomes more applicable, and a comparison is presented of system requirements for permanent and superconducting (SC) magnetization systems. Included in this analysis is an investigation of the ability of superconducting magnet based systems to overcome the parasitic power penalty of the cryocooler used to keep SC windings at cryogenic temperatures. Scaling relationships were used to develop the initial specification for a SC magnet-based active magnetic regeneration (AMR) system. An optimized superconducting magnet was designed to support this system. In this analysis, we show that the SC magnet system consisting of two 0.38 m3 regenerators is capable of producing 285 kW of cooling power with a T of 28 K. A system COP of 4.02 including cryocooler and fan losses which illustrates that an SC magnet-based system can operate with efficiency comparable to traditional systems and deliver large cooling powers of 285.4 kW (81.2 Tons).

Abdelaziz, Omar [ORNL; West, David L [ORNL; Mallow, Anne M [ORNL

2012-01-01T23:59:59.000Z

384

Estimated United States Residential Energy Use in 2005  

DOE Green Energy (OSTI)

A flow chart depicting energy flow in the residential sector of the United States economy in 2005 has been constructed from publicly available data and estimates of national energy use patterns. Approximately 11,000 trillion British Thermal Units (trBTUs) of electricity and fuels were used throughout the United States residential sector in lighting, electronics, air conditioning, space heating, water heating, washing appliances, cooking appliances, refrigerators, and other appliances. The residential sector is powered mainly by electricity and natural gas. Other fuels used include petroleum products (fuel oil, liquefied petroleum gas and kerosene), biomass (wood), and on-premises solar, wind, and geothermal energy. The flow patterns represent a comprehensive systems view of energy used within the residential sector.

Smith, C A; Johnson, D M; Simon, A J; Belles, R D

2011-12-12T23:59:59.000Z

385

Policies and Market Factors Driving Wind Power Development in the United States  

DOE Green Energy (OSTI)

In the United States, there has been substantial recent growth in wind energy generating capacity, with growth averaging 24% annually during the past five years. With this growth, an increasing number of states are experiencing investment in wind energy. Wind installations currently exist in about half of all U.S. states. This paper explores the policies and market factors that have been driving utility-scale wind energy development in the United States, particularly in the states that have achieved a substantial amount of wind energy investment in recent years. Although there are federal policies and overarching market issues that are encouraging investment nationally, much of the recent activity has resulted from state-level policies or localized market drivers. In this paper, we identify the key policies, incentives, regulations, and markets affecting development, and draw lessons from the experience of leading states that may be transferable to other states or regions. We provide detailed discussions of the drivers for wind development in a dozen leading states-California, Colorado, Iowa, Kansas, Minnesota, New York, Oregon, Pennsylvania, Texas, Washington, West Virginia, and Wyoming.

Bird, L.; Parsons, B.; Gagliano, T.; Brown, M.; Wiser, R.; Bolinger, M.

2003-07-01T23:59:59.000Z

386

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network (OSTI)

Amarnath, M. Blatt, Variable refrigerant flow: where, why,simulation in the variable refrigerant flow air-conditioningsimulation of the variable refrigerant flow air conditioning

Hong, Tainzhen

2010-01-01T23:59:59.000Z

387

Opportunities for Energy Efficiency and Automated Demand Response in Industrial Refrigerated Warehouses in California  

E-Print Network (OSTI)

D. Brown (2004). Industrial Refrigeration Best PracticesD. Brown (2004). Industrial Refrigeration Best Practicesoutlet – common in industrial refrigeration Source: Wilcox,

Lekov, Alex

2009-01-01T23:59:59.000Z

388

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

E-Print Network (OSTI)

refrigeration products use vapor compression technology toicemakers and non-vapor compression refrigerators and+4.5) million non-vapor compression refrigerators in U.S.

Greenblatt, Jeffery B.

2013-01-01T23:59:59.000Z

389

Community wind power ownership schemes in Europe and their relevance to the United States  

DOE Green Energy (OSTI)

With varying success, the United States and Europe have followed a more or less parallel path of policies to support wind development over the past twenty years. Feed-in laws and tax incentives first popularized in California in the early 1980s and greatly expanded upon in Europe during the 1990s are gradually giving way to market-based support mechanisms such as renewable portfolio standards, which are being implemented in one form or another in ten US states and at least three European nations. At the same time, electricity markets are being liberalized in both the US and Europe, and many electricity consumers are being given the choice to support the development of renewable energy through higher tariffs, both in traditionally regulated and newly competitive markets. One notable area in which wind development in Europe and United States has not evolved in common, however, is with respect to the level of community ownership of wind turbines or clusters. While community ownership of wind projects is unheard of in the United States, in Europe, local wind cooperatives or other participatory business schemes have been responsible for a large share of total wind development. In Denmark, for example, approximately 80% of all wind turbines are either individually or cooperatively owned, and a similar pattern holds in Germany, the world leader in installed wind capacity. Sweden also has a strong wind cooperative base, and the UK has recently made forays into community wind ownership. Why is it that wind development has evolved this way in Europe, but not in the United States? What incremental effect have community-owned wind schemes had on European wind development? Have community-owned wind schemes driven development in Europe, or are they merely a vehicle through which the fundamental driving institutions have been channeled? Is there value to having community wind ownership in the US? Is there reason to believe that such schemes would succeed in the US? If so, which model seems most appropriate, and what barriers--legal, regulatory, tax, market, or investment--stand in the way of implementing such a scheme? These are the questions this report seeks to address. The report begins with a discussion of the relative advantages and disadvantages of community wind ownership, as opposed to the large commercially-owned projects that have so far dominated US wind development. Next, four detailed case studies relate community-owned wind experience in Denmark, Sweden, the UK, Germany, focusing primarily on the different participatory models employed in each country. The report then categorizes the various models into three main groupings--community-led, developer-led, and investment funds--and draws general conclusions about the success of each category in Europe, and the conditions that dictate the effective use of one approach over another. Finally, the focus shifts to the US, where the report discusses the domestic barriers facing each model category, and identifies the category offering the most value with the fewest barriers to implementation. The report concludes with a high-level introduction to potential applications for community wind ownership within the United States.

Bolinger, Mark

2001-05-15T23:59:59.000Z

390

Floating Refrigerant Loop Based on R-134a Refrigerant Cooling of High-Heat Flux Electronics  

SciTech Connect

The Oak Ridge National Laboratory (ORNL) Power Electronics and Electric Machinery Research Center (PEEMRC) have been developing technologies to address the thermal issues associated with hybrid vehicles. Removal of the heat generated from electrical losses in traction motors and their associated power electronics is essential for the reliable operation of motors and power electronics. As part of a larger thermal control project, which includes shrinking inverter size and direct cooling of electronics, ORNL has developed U.S. Patent No. 6,772,603 B2, ''Methods and Apparatus for Thermal Management of Vehicle Systems and Components'' [1], and patent pending, ''Floating Loop System for Cooling Integrated Motors and Inverters Using Hot Liquid Refrigerant'' [2]. The floating-loop system provides a large coefficient of performance (COP) for hybrid-drive component cooling. This loop (based on R-134a) is integrated with a vehicle's existing air-conditioning (AC) condenser, which dissipates waste heat to the ambient air. Because the temperature requirements for cooling of power electronics and electric machines are not as low as that required for passenger compartment air, this adjoining loop can operate on the high-pressure side of the existing AC system. This arrangement also allows the floating loop to run without the need for the compressor and only needs a small pump to move the liquid refrigerant. For the design to be viable, the loop must not adversely affect the existing system. The loop should also provide a high COP, a flat-temperature profile, and low-pressure drop. To date, the floating-loop test prototype has successfully removed 2 kW of heat load in a 9 kW automobile passenger AC system with and without the automotive AC system running. The COP for the tested floating-loop system ranges from 40-45, as compared to a typical AC system COP of about 2-4. The estimated required waste-heat load for future hybrid applications is 5.5 kW and the existing system could be easily scaleable for this larger load.

Lowe, K.T.

2005-10-07T23:59:59.000Z

391

Floating Refrigerant Loop Based on R-134a Refrigerant Cooling of High-Heat Flux Electronics  

SciTech Connect

The Oak Ridge National Laboratory (ORNL) Power Electronics and Electric Machinery Research Center (PEEMRC) have been developing technologies to address the thermal issues associated with hybrid vehicles. Removal of the heat generated from electrical losses in traction motors and their associated power electronics is essential for the reliable operation of motors and power electronics. As part of a larger thermal control project, which includes shrinking inverter size and direct cooling of electronics, ORNL has developed U.S. Patent No. 6,772,603 B2, ''Methods and Apparatus for Thermal Management of Vehicle Systems and Components'' [1], and patent pending, ''Floating Loop System for Cooling Integrated Motors and Inverters Using Hot Liquid Refrigerant'' [2]. The floating-loop system provides a large coefficient of performance (COP) for hybrid-drive component cooling. This loop (based on R-134a) is integrated with a vehicle's existing air-conditioning (AC) condenser, which dissipates waste heat to the ambient air. Because the temperature requirements for cooling of power electronics and electric machines are not as low as that required for passenger compartment air, this adjoining loop can operate on the high-pressure side of the existing AC system. This arrangement also allows the floating loop to run without the need for the compressor and only needs a small pump to move the liquid refrigerant. For the design to be viable, the loop must not adversely affect the existing system. The loop should also provide a high COP, a flat-temperature profile, and low-pressure drop. To date, the floating-loop test prototype has successfully removed 2 kW of heat load in a 9 kW automobile passenger AC system with and without the automotive AC system running. The COP for the tested floating-loop system ranges from 40-45, as compared to a typical AC system COP of about 2-4. The estimated required waste-heat load for future hybrid applications is 5.5 kW and the existing system could be easily scaleable for this larger load.

Lowe, K.T.

2005-10-07T23:59:59.000Z

392

Ongoing Commissioning of a high efficiency supermarket with a ground coupled carbon dioxide refrigeration plant  

E-Print Network (OSTI)

A significant reduction in the energy consumption and greenhouse gas emissions of supermarkets can be reached by the combination of several innovative components and the continuous optimization of their operation. A German food retail chain developed a new supermarket concept combining several innovative solutions for the refrigeration, lighting and heating/ventilation with the goal to reduce the energy consumption by about 30% compared to a standard subsidiary. A highly insulated building envelope, the use of daylight and covered refrigeration units contribute jointly to reach the goals. The key component of the concept is a carbon dioxide refrigeration plant with waste heat recovery. To reduce the efficiency losses in supercritical operation, carbon dioxide is cooled through a borehole heat exchanger using the ground as a heat sink. In the paper the design concept, the results of simulation studies and of the first monitoring year are presented and discussed.

Rehault, N.; Kalz, D.

2012-01-01T23:59:59.000Z

393

Small Commercial Refrigeration Incentive | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Small Commercial Refrigeration Incentive Small Commercial Refrigeration Incentive Small Commercial Refrigeration Incentive < Back Eligibility Agricultural Commercial Industrial Institutional Nonprofit Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Incentives over $5,000 must be pre-approved Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Outside Air Economizers: $1,250 Evaporator Fan Motors: $20 - $100 Evaporator Fan Motor Controls: $550 Door/Frame Heater Controls: $50 per door Case Light Occupancy Controls: $40 LED Refrigerator and Freezer Case Light Fixtures: $6 - $15 per foot Energy Star Ice Machines: $50 - $75 Efficient Compressors: $200 Display Case Strip-Curtain and Continuous Covers: $6 per foot

394

Cospolich Refrigerator: Proposed Penalty (2013-CE-5314)  

Energy.gov (U.S. Department of Energy (DOE))

DOE alleged in a Notice of Proposed Civil Penalty that Cospolich Refrigerator Co, Inc. failed to certify walk-in cooler or freezer components as compliant with the energy conservation standards.

395

Refrigerator Manufacturers: Proposed Penalty (2013-CE-5341)  

Energy.gov (U.S. Department of Energy (DOE))

DOE alleged in a Notice of Proposed Civil Penalty that Refrigerator Manufacturers, LLC failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards.

396

Defrost Temperature Termination in Supermarket Refrigeration Systems  

SciTech Connect

The objective of this project was to determine the potential energy savings associated with implementing demand defrost strategies to defrost supermarket refrigerated display case evaporators, as compared to the widely accepted current practice of controlling display case defrost cycles with a preset timer. The defrost heater energy use of several representative display case types was evaluated. In addition, demand defrost strategies for refrigerated display cases as well as those used in residential refrigerator/freezers were evaluated. Furthermore, it is anticipated that future work will include identifying a preferred defrost strategy, with input from Retail Energy Alliance members. Based on this strategy, a demand defrost system will be designed which is suitable for supermarket refrigerated display cases. Limited field testing of the preferred defrost strategy will be performed in a supermarket environment.

Fricke, Brian A [ORNL; Sharma, Vishaldeep [ORNL

2011-11-01T23:59:59.000Z

397

Elastic Metal Alloy Refrigerants: Thermoelastic Cooling  

SciTech Connect

BEETIT Project: UMD is developing an energy-efficient cooling system that eliminates the need for synthetic refrigerants that harm the environment. More than 90% of the cooling and refrigeration systems in the U.S. today use vapor compression systems which rely on liquid to vapor phase transformation of synthetic refrigerants to absorb or release heat. Thermoelastic cooling systems, however, use a solid-state material—an elastic shape memory metal alloy—as a refrigerant and a solid to solid phase transformation to absorb or release heat. UMD is developing and testing shape memory alloys and a cooling device that alternately absorbs or creates heat in much the same way as a vapor compression system, but with significantly less energy and a smaller operational footprint.

2010-10-01T23:59:59.000Z

398

Variable Refrigerant Flow Air Conditioners and Heat Pumps for Commercial Buildings  

Science Conference Proceedings (OSTI)

Multi-split heat pumps have evolved from a technology suitable for residential and light commercial buildings to variable refrigerant flow (VRF) systems that can provide efficient space conditioning for large commercial buildings. VRF systems are enhanced versions of ductless multi-split systems, permitting more indoor units to be connected to each outdoor unit and providing additional features such as simultaneous heating and cooling and heat recovery. VRF systems are very popular in Asia and Europe and...

2008-01-25T23:59:59.000Z

399

Working Fluids Low Global Warming Potential Refrigerants  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Working Fluids Low GWP Working Fluids Low GWP Refrigerants - CRADA Ed Vineyard Oak Ridge National Laboratory vineyardea@ornl.gov (865) 574-0576 3 April 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: - High GWP refrigerants increase CO 2 equivalent emissions for HVAC&R equipment - Low GWP alternatives may increase energy consumption, introduce safety risks, require significant modifications to equipment, and have higher costs

400

Combined cold compressor/ejector helium refrigerator  

DOE Patents (OSTI)

A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

Brown, Donald P. (Southold, NY)

1985-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Working Fluids Low Global Warming Potential Refrigerants  

NLE Websites -- All DOE Office Websites (Extended Search)

Working Fluids Low GWP Working Fluids Low GWP Refrigerants - CRADA Ed Vineyard Oak Ridge National Laboratory vineyardea@ornl.gov (865) 574-0576 3 April 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: - High GWP refrigerants increase CO 2 equivalent emissions for HVAC&R equipment - Low GWP alternatives may increase energy consumption, introduce safety risks, require significant modifications to equipment, and have higher costs

402

ARI delegation to Japan on Alternative Refrigerants  

SciTech Connect

Researchers from ARI member companies spoke at the International Conference on Alternative Refrigerants in Tokyo and visited several Japanese organizations for the purpose of exchanging information on alternative refrigerants. The specific purpose of the meetings was to review the methods being utilized to screen alternatives to CFCs and HCFCs: materials compatibility screening methods, lubricant testing techniques, as well as flammability studies. A list of papers presented at the conference is included.

Not Available

1993-02-01T23:59:59.000Z

403

BNL Refrigerant Overview Presentation to the  

E-Print Network (OSTI)

0.25 4700 Cold boxes, environmental chambers R-718 Water 212 0 N/A Steam-driven absorption chiller 4750 Older centrifugal chillers (>200 tons) R-12 CFC -20 1 10900 Old refrigerators and vehicle A/C R-13/C mach. R-123 HCFC 81 1.3 77 Newer centrifugal chillers (>200 tons) R-134a HFC -15 0 1430 Refrigerators

Homes, Christopher C.

404

Combined cold compressor/ejector helium refrigerator  

DOE Patents (OSTI)

A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

Brown, D.P.

1984-06-05T23:59:59.000Z

405

Advanced Gas Turbine Guidelines: Performance Retention for GE 7F Unit in Peaking Operation: Durability Surveillance at Potomac Elect ric Power Company's Station H  

Science Conference Proceedings (OSTI)

Worldwide pressures to reduce power generation costs have encouraged domestic and foreign manufacturers to build high-efficiency gas turbines implementing the latest technological advances. To assure the staying power of these turbines, EPRI launched a multi-year durability surveillance program. This report discusses performance monitoring and analysis of a General Electric 7F unit in peaking operation.

1999-04-26T23:59:59.000Z

406

Energy Efficient Operation of Ammonia Refrigeration Systems  

SciTech Connect

Ammonia refrigeration systems typically offer many energy efficiency opportunities because of their size and complexity. This paper develops a model for simulating single-stage ammonia refrigeration systems, describes common energy saving opportunities, and uses the model to quantify those opportunities. The simulation model uses data that are typically available during site visits to ammonia refrigeration plants and can be calibrated to actual consumption and performance data if available. Annual electricity consumption for a base-case ammonia refrigeration system is simulated. The model is then used to quantify energy savings for six specific energy efficiency opportunities; reduce refrigeration load, increase suction pressure, employ dual suction, decrease minimum head pressure set-point, increase evaporative condenser capacity, and reclaim heat. Methods and considerations for achieving each saving opportunity are discussed. The model captures synergistic effects that result when more than one component or parameter is changed. This methodology represents an effective method to model and quantify common energy saving opportunities in ammonia refrigeration systems. The results indicate the range of savings that might be expected from common energy efficiency opportunities.

Mohammed, Abdul Qayyum [University of Dayton, Ohio; Wenning, Thomas J [ORNL; Sever, Franc [University of Dayton, Ohio; Kissock, Professor Kelly [University of Dayton, Ohio

2013-01-01T23:59:59.000Z

407

Land Use Requirements of Modern Wind Power Plants in the United States  

DOE Green Energy (OSTI)

This report provides data and analysis of the land use associated with modern, large wind power plants (defined as greater than 20 megawatts (MW) and constructed after 2000). The analysis discusses standard land-use metrics as established in the life-cycle assessment literature, and then discusses their applicability to wind power plants. The report identifies two major 'classes' of wind plant land use: 1) direct impact (i.e., disturbed land due to physical infrastructure development), and 2) total area (i.e., land associated with the complete wind plant project). The analysis also provides data for each of these classes, derived from project applications, environmental impact statements, and other sources. It attempts to identify relationships among land use, wind plant configuration, and geography. The analysts evaluated 172 existing or proposed projects, which represents more than 26 GW of capacity. In addition to providing land-use data and summary statistics, they identify several limitations to the existing wind project area data sets, and suggest additional analysis that could aid in evaluating actual land use and impacts associated with deployment of wind energy.

Denholm, P.; Hand, M.; Jackson, M.; Ong, S.

2009-08-01T23:59:59.000Z

408

Global warming impacts of ozone-safe refrigerants and refrigeration, heating, and air-conditioning technologies  

SciTech Connect

International agreements mandate the phase-out of many chlorine containing compounds that are used as the working fluid in refrigeration, air-conditioning, and heating equipment. Many of the chemical compounds that have been proposed, and are being used in place of the class of refrigerants eliminated by the Montreal Protocol are now being questioned because of their possible contributions to global warming. Natural refrigerants are put forth as inherently superior to manufactured refrigerants because they have very low or zero global warming potentials (GWPs). Questions are being raised about whether or not these manufactured refrigerants, primarily hydrofluorocarbons (HFCs), should be regulated and perhaps phased out in much the same manner as CFCs and HCFCs. Several of the major applications of refrigerants are examined in this paper and the results of an analysis of their contributions to greenhouse warming are presented. Supermarket refrigeration is shown to be an application where alternative technologies have the potential to reduce emissions of greenhouse gases (GHG) significantly with no clear advantage to either natural or HFC refrigerants. Mixed results are presented for automobile air conditioners with opportunities to reduce GHG emissions dependent on climate and comfort criteria. GHG emissions for hermetic and factory built systems (i.e. household refrigerators/freezers, unitary equipment, chillers) are shown to be dominated by energy use with much greater potential for reduction through efficiency improvements than by selection of refrigerant. The results for refrigerators also illustrate that hydrocarbon and carbon dioxide blown foam insulation have lower overall effects on GHG emissions than HFC blown foams at the cost of increased energy use.

Fischer, S.; Sand, J.; Baxter, V.

1997-12-01T23:59:59.000Z

409

Low-GWP Refrigerants Research Project | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emerging Technologies » Low-GWP Refrigerants Research Project Emerging Technologies » Low-GWP Refrigerants Research Project Low-GWP Refrigerants Research Project The U.S. Department of Energy is currently conducting research into low global warming potential (GWP) refrigerants. As concerns about climate change intensify, it is becoming increasingly clear that suitable low-GWP refrigerants will be needed for both new and existing residential and commercial heating, ventilation, air conditioning, and refrigeration (HVAC&R) equipment. Project Description This project seeks to develop alternative refrigerants for HVAC&R equipment. The overall environmental impacts of alternative refrigerants will be assessed using a life cycle climate performance model that accounts for direct emissions associated with refrigerant leaks and indirect

410

Multi-area power system state estimation utilizing boundary measurements and phasor measurement units ( PMUs)  

E-Print Network (OSTI)

The objective of this thesis is to prove the validity of a multi-area state estimator and investigate the advantages it provides over a serial state estimator. This is done utilizing the IEEE 118 Bus Test System as a sample system. This thesis investigates the benefits that stem from utilizing a multi-area state estimator instead of a serial state estimator. These benefits are largely in the form of increased accuracy and decreased processing time. First, the theory behind power system state estimation is explained for a simple serial estimator. Then the thesis shows how conventional measurements and newer, more accurate PMU measurements work within the framework of weighted least squares estimation. Next, the multi-area state estimator is examined closely and the additional measurements provided by PMUs are used to increase accuracy and computational efficiency. Finally, the multi-area state estimator is tested for accuracy, its ability to detect bad data, and computation time.

Freeman, Matthew A

2006-08-01T23:59:59.000Z

411

Power conversion unit studies for the next generation nuclear plant coupled to a high-temperature steam electrolysis facility  

E-Print Network (OSTI)

The Department of Energy and the Idaho National Laboratory are developing a Next Generation Nuclear Plant (NGNP) to serve as a demonstration of state-of-the-art nuclear technology. The purpose of the demonstration is two fold: 1) efficient low cost energy generation and 2) hydrogen production. Although a next generation plant could be developed as a single-purpose facility, early designs are expected to be dual-purpose. While hydrogen production and advanced energy cycles are still in their early stages of development, research towards coupling a high temperature reactor, electrical generation and hydrogen production is under way. Many aspects of the NGNP must be researched and developed to make recommendations on the final design of the plant. Parameters such as working conditions, cycle components, working fluids, and power conversion unit configurations must be understood. Three configurations of the power conversion unit were modeled using the process code HYSYS; a three-shaft design with 3 turbines and 4 compressors, a combined cycle with a Brayton top cycle and a Rankine bottoming cycle, and a reheated cycle with 3 stages of reheat were investigated. A high temperature steam electrolysis hydrogen production plant was coupled to the reactor and power conversion unit by means of an intermediate heat transport loop. Helium, CO2, and an 80% nitrogen, 20% helium mixture (by weight) were studied to determine the best working fluid in terms cycle efficiency and development cost. In each of these configurations the relative heat exchanger size and turbomachinery work were estimated for the different working fluids. Parametric studies away from the baseline values of the three-shaft and combined cycles were performed to determine the effect of varying conditions in the cycle. Recommendations on the optimal working fluid for each configuration were made. The helium working fluid produced the highest overall plant efficiency for the three-shaft and reheat cycle; however, the nitrogen-helium mixture produced similar efficiency with smaller component sizes. The CO2 working fluid is recommend in the combined cycle configuration.

Barner, Robert Buckner

2006-12-01T23:59:59.000Z

412

Optimal sizing study of hybrid wind/PV/diesel power generation unit  

Science Conference Proceedings (OSTI)

In this paper, a methodology of sizing optimization of a stand-alone hybrid wind/PV/diesel energy system is presented. This approach makes use of a deterministic algorithm to suggest, among a list of commercially available system devices, the optimal number and type of units ensuring that the total cost of the system is minimized while guaranteeing the availability of the energy. The collection of 6 months of data of wind speed, solar radiation and ambient temperature recorded for every hour of the day were used. The mathematical modeling of the main elements of the hybrid wind/PV/diesel system is exposed showing the more relevant sizing variables. A deterministic algorithm is used to minimize the total cost of the system while guaranteeing the satisfaction of the load demand. A comparison between the total cost of the hybrid wind/PV/diesel energy system with batteries and the hybrid wind/PV/diesel energy system without batteries is presented. The reached results demonstrate the practical utility of the used sizing methodology and show the influence of the battery storage on the total cost of the hybrid system. (author)

Belfkira, Rachid; Zhang, Lu; Barakat, Georges [Groupe de Recherche en Electrotechnique et Automatique du Havre, University of Le Havre, 25 rue Philippe Lebon, BP 1123, 76063 Le Havre (France)

2011-01-15T23:59:59.000Z

413

Supporting Solar Power in Renewables Portfolio Standards: Experience from the United States  

DOE Green Energy (OSTI)

Among the available options for encouraging the increased deployment of renewable electricity, renewables portfolio standards (RPS) have become increasingly popular. The RPS is a relatively new policy mechanism, however, and experience with its use is only beginning to emerge. One key concern that has been voiced is whether RPS policies will offer adequate support to a wide range of renewable energy technologies and applications or whether, alternatively, RPS programs will favor a small number of the currently least-cost forms of renewable energy. This report documents the design of and early experience with state-level RPS programs in the United States that have been specifically tailored to encourage a wider diversity of renewable energy technologies, and solar energy in particular. As shown here, state-level RPS programs specifically designed to support solar have already proven to be an important, albeit somewhat modest, driver for solar energy deployment, and those impacts are projected to continue to build in the coming years. State experience in supporting solar energy with RPS programs is mixed, however, and full compliance with existing requirements has not been achieved. The comparative experiences described herein highlight the opportunities and challenges of applying an RPS to specifically support solar energy, as well as the importance of policy design details to ensuring that program goals are achieved.

Wiser, Ryan; Barbose, Galen; Holt, Edward

2010-10-01T23:59:59.000Z

414

PTC, ITC, or Cash Grant? An Analysis of the Choice Facing Renewable Power Projects in the United States  

SciTech Connect

Renewable power technologies are inherently capital-intensive, often (but not always) with relatively high construction costs and low operating costs. For this reason, renewable power technologies are typically more sensitive to the availability and cost of financing than are natural gas power plants, for example. In the United States, the bulk of renewable project finance in recent years has been provided by 'tax equity investors' (typically large investment banks and insurance companies) who partner with project developers through highly specialized financing structures (Bolinger, 2009; Cory et al., 2008; Harper et al., 2007). These structures have been designed primarily to capitalize on federal support for renewable power technologies, which has historically come in the form of tax credits and accelerated depreciation deductions. The number of tax equity investors active in the renewable power market has declined precipitously, however, as a result of the financial crisis that began unfolding across the globe in the summer of 2008. The resulting shortage and increased cost of project financing has, in turn, slowed the development of new renewable power projects, leading to layoffs throughout the entire industry supply chain. In recognition of the fact that tax-based policy incentives are not particularly effective when tax burdens are shrinking or non-existent, Congress included several provisions in 'The American Recovery and Reinvestment Act of 2009' (ARRA 2009) designed to make federal incentives for renewable power technologies more useful. Among these provisions is one that allows projects eligible to receive the production tax credit ('the PTC', see Text Box 1) to instead elect the investment tax credit ('the ITC', see Text Box 2). Another provision enables ITC-eligible projects (which now include most PTC-eligible renewable power projects) to instead receive--for a limited time only--a cash grant of equivalent value. These two provisions (among others) could have a significant impact on how renewable power projects are financed over the next few years. The purpose of this report is to both quantitatively and qualitatively analyze, from the project developer/owner perspective, the choice between the PTC and the ITC (or equivalent cash grant) for a number of different renewable power technologies.1 Because the two credits are structured differently, and apply in different ways to different technologies, the choice between the two lends itself to quantitative financial analysis of the conditions under which either the PTC or the ITC would, at least in theory, provide greater financial value. Qualitative considerations may be equally important, however, particularly in instances where quantitative differences are modest. This report proceeds as follows. Section 2 provides a brief summary of ARRA 2009, with some emphasis on those provisions designed to ease the liquidity crisis facing the renewable power sector. Section 3 describes the quantitative analysis methodology, as well as modeling results for wind, open-loop biomass, closed-loop biomass, geothermal, and landfill gas projects. Section 4 discusses a number of qualitative considerations that may play as important of a role as quantitative results in deciding between the PTC and the ITC (or equivalent cash grant). Section 5 concludes, and an Appendix provides supplemental tables that present quantitative analysis results conducted at different discount rates.

Bolinger, Mark; Wiser, Ryan; Cory, Karlynn; James, Ted

2009-03-11T23:59:59.000Z

415

Tests of the 30-MJ superconducting magnetic-energy storage unit  

DOE Green Energy (OSTI)

A 30-MJ (8.4 kWh) superconducting magnetic energy storage (SMES) unit with a 10-MW converter was installed during the later months of 1982 at the Bonneville Power Administration (BPA) Tacoma substation in Tacoma, Washington. The unit, which is capable of absorbing and releasing up to 10 MJ of energy at a frequency of 0.35 Hz, was designed to damp the dominant power swing mode of the Pacific AC Intertie. Extensive tests were performed with the unit during the first half of 1983. This paper will review the major components of the storage unit and describe the startup and steady state operating experience with the coil, dewar, refrigerator and converter. The unit has absorbed power up to a level of 11.8 Mw. Real power was modulated following a sinusoidal power demand with frequencies from 0.1 to 1.2 Hz and a power level up to +- 8.3 MW. The unit has performed in accordance with design expectations and no major problems have developed.

Boenig, H.J.; Dean, J.W.; Rogers, J.D.; Schermer, R.I.; Hauer, J.F.

1983-01-01T23:59:59.000Z

416

Japanese Refrigerators : A Field Performance Analysis : Field Inspection Data, Screening and Compilation.  

SciTech Connect

The Pacific Northwest Electric Power Planning and Conservation Act, signed into law December 5, 1980, mandated regionwide energy conservation practices. Under the act, BPA must identify and implement cost-effective electric energy options and programs for the Pacific Northwest. The Residential Technology Section in the Division of Resource Management supports current residential energy conservation programs and designs and conducts various research and development projects, of which this project is one. Laboratory test procedures used by the Japanese had shown their refrigerators to be about 50 percent more efficient than American-made refrigerators. A previous BPA study tested 12 Japanese refrigerators according to the USDOE laboratory procedure. This study showed that when tested to the DOE procedure, the Japanese refrigerators used about 43 percent more energy than when tested by the Japanese procedure. This study compared in-home energy use of 12 Japanese refrigerators identical to those in the laboratory test to both the Japanese and USDOE laboratory tests. 2 figs., 3 tabs.

Nelson, Peter E.

1989-11-01T23:59:59.000Z

417

Advanced Underground Gas Storage Concepts Refrigerated-Mined Cavern Storage  

NLE Websites -- All DOE Office Websites (Extended Search)

UNDERGROUND GAS STORAGE CONCEPTS UNDERGROUND GAS STORAGE CONCEPTS REFRIGERATED-MINED CAVERN STORAGE FINAL REPORT DOE CONTRACT NUMBER DE-AC26-97FT34349 SUBMITTED BY: PB-KBB INC. 11757 KATY FREEWAY, SUITE 600 HOUSTON, TX 77079 SEPTEMBER 1998 Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily

418

DOE Closes Investigation of Arcelik's Blomberg Refrigerator | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Arcelik's Blomberg Refrigerator Arcelik's Blomberg Refrigerator DOE Closes Investigation of Arcelik's Blomberg Refrigerator September 1, 2010 - 4:37pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Arcelik's Blomberg refrigerator-freezer model # BRFB1450. The Department opened this investigation based on a complaint. DOE subpoenaed information from Arcelik, reviewed Arcelik's response, and performed its own testing of this model. Based on our investigation and test results, DOE has determined this model to be compliant with federal energy conservation standards. Notice of Compliance Determination Addthis Related Articles DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Closes Investigation of Whirlpool's Maytag Refrigerator

419

High Efficiency Low Emission Supermarket Refrigeration Research Project |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High Efficiency Low Emission Supermarket High Efficiency Low Emission Supermarket Refrigeration Research Project High Efficiency Low Emission Supermarket Refrigeration Research Project The U.S. Department of Energy (DOE) is currently conducting research into high efficiency, low emission supermarket refrigeration technologies. Project Description The project involves the development of a supermarket refrigeration system that can reduce greenhouse gas emissions and energy consumption when compared to existing systems. The challenge is to design a system that is capable of achieving low refrigerant leak rates while significantly reducing both the energy consumption and the refrigerant charge size. Project Partners Research is being undertaken between DOE and Oak Ridge National Laboratory. Project Goals

420

ASSESSMENT OF THE RADIONUCLIDE COMPOSITION OF "HOT PARTICLES" SAMPLED IN THE CHERNOBYL NUCLEAR POWER PLANT FOURTH REACTOR UNIT  

SciTech Connect

Fuel-containing materials sampled from within the Chernobyl Nuclear Power Plant (ChNPP) 4th Reactor Unit Confinement Shelter were spectroscopically studied for gamma and alpha content. Isotopic ratios for cesium, europium, plutonium, americium, and curium were identified and the fuel burnup in these samples was determined. A systematic deviation in the burnup values based on the cesium isotopes, in comparison with other radionuclides, was observed. The conducted studies were the first ever performed to demonstrate the presence of significant quantities of {sup 242}Cm and {sup 243}Cm. It was determined that there was a systematic underestimation of activities of transuranic radionuclides in fuel samples from inside of the ChNPP Confinement Shelter, starting from {sup 241}Am (and going higher), in comparison with the theoretical calculations.

Farfan, E.; Jannik, T.; Marra, J.

2011-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Evaluation of severe accident risks and the potential for risk reduction: Surry Power Station, Unit 1: Draft report for comment  

Science Conference Proceedings (OSTI)

The Severe Accident Risk Reduction Program (SARRP) has completed a rebaselining of the risks to the public from a particular pressurized water reactor with a subatmospheric containment (Surry, Unit 1). Emphasis was placed on determining the magnitude and character of the uncertainties, rather than focusing on a point estimate. The risk-reduction potential of a set of proposed safety option backfits was also studied, and their costs and benefits were also evaluated. It was found that the risks from internal events are generally lower than previously evaluated in the Reactor Safety Study (RSS). However, certain unresolved issues (such as direct containment heating) caused the top of the uncertainty band to appear at a level that is comparable with the RSS point estimate. None of the postulated safety options appears to be cost effective for the Surry power plant. This work supports the Nuclear Regulatory Commission's assessment of severe accidents in NUREG-1150.

Benjamin, A.S.; Boyd, G.J.; Kunsman, D.M.; Murfin, W.B.; Williams, D.C.

1987-02-01T23:59:59.000Z

422

Well simulation using Refrigerant 114  

DOE Green Energy (OSTI)

A simple method for the investigation of thermodynamic (substance) similarity in the two-phase domain is introduced based on the assumptions of a simplified model fluid. According to this method, the investigation of the conditions for thermodynamic similarity between substances in the two-phase region reveals the important role the latent heat of evaporation (h/sub fg/) plays in the definition of the property scales. These greatly influence the dynamic and geometric similarity of the process under investigation. The introduction of the thermodynamic similarity property scales into the energy conservation equations for a certain process (e.g., flow up a geothermal well) brings forth a thermodynamic length scale and kinetic energy scale. Refrigerant 114 has been examined for similarity with water substance according to this method and found to be adequate for geothermal well simulation in the laboratory. Low pressures and temperatures and a substantial reduction of mass flow rates and geometric scales are a few of the advantages of using R114 for such experiments.

Nikitopoulos, D.E.; Dickinson, D.A.; DiPippo, R.; Maeder, P.F.

1984-06-01T23:59:59.000Z

423

Opportunities for Energy Efficiency and Automated Demand Response in Industrial Refrigerated Warehouses in California  

E-Print Network (OSTI)

system. The refrigeration system design involves sizing ofDesign Essentials for Refrigerated Storage Facilities, American Society for Heating Refrigeration anddesign considerations are mostly related to wall and roof types, shell insulation, and the refrigeration

Lekov, Alex

2009-01-01T23:59:59.000Z

424

Induced Radioactivity and Waste Classification of Reactor Zone Components of the Chernobyl Nuclear Power Plant Unit 1 After Final Shutdown  

SciTech Connect

The dismantlement of the reactor core materials and surrounding structural components is a major technical concern for those planning closure and decontamination and decommissioning of the Chernobyl Nuclear Power Plant (NPP). Specific issues include when and how dismantlement should be accomplished and what the radwaste classification of the dismantled system would be at the time it is disassembled. Whereas radiation levels and residual radiological characteristics of the majority of the plant systems are directly measured using standard radiation survey and radiochemical analysis techniques, actual measurements of reactor zone materials are not practical due to high radiation levels and inaccessibility. For these reasons, neutron transport analysis was used to estimate induced radioactivity and radiation levels in the Chernobyl NPP Unit 1 reactor core materials and structures.Analysis results suggest that the optimum period of safe storage is 90 to 100 yr for the Unit 1 reactor. For all of the reactor components except the fuel channel pipes (or pressure tubes), this will provide sufficient decay time to allow unlimited worker access during dismantlement, minimize the need for expensive remote dismantlement, and allow for the dismantled reactor components to be classified as low- or medium-level radioactive waste. The fuel channel pipes will remain classified as high-activity waste requiring remote dismantlement for hundreds of years due to the high concentration of induced {sup 63}Ni in the Zircaloy pipes.

Bylkin, Boris K. [Russian Research Center 'Kurchatov Institute' (Russian Federation); Davydova, Galina B. [Russian Research Center 'Kurchatov Institute' (Russian Federation); Zverkov, Yuri A. [Russian Research Center 'Kurchatov Institute' (Russian Federation); Krayushkin, Alexander V. [Russian Research Center 'Kurchatov Institute' (Russian Federation); Neretin, Yuri A. [Chernobyl Nuclear Power Plant (Ukraine); Nosovsky, Anatoly V. [Slavutych Division of the International Chernobyl Center (Ukraine); Seyda, Valery A. [Chernobyl Nuclear Power Plant (Ukraine); Short, Steven M. [Pacific Northwest National Laboratory (United States)

2001-10-15T23:59:59.000Z

425

Fridge of the future: Designing a one-kilowatt-hour/day domestic refrigerator-freezer  

SciTech Connect

An industry/government Cooperative Research and Development Agreement (CRADA) was established to evaluate and test design concepts for a domestic refrigerator-freezer unit that represents approximately 60% of the US market. The goal of the CRADA was to demonstrate advanced technologies which reduce, by 50 percent, the 1993 NAECA standard energy consumption for a 20 ft{sup 3} (570 I) top-mount, automatic-defrost, refrigerator-freezer. For a unit this size, the goal translated to an energy consumption of 1.003 kWh/d. The general objective of the research was to facilitate the introduction of cost-efficient technologies by demonstrating design changes that can be effectively incorporated into new products. A 1996 model refrigerator-freezer was selected as the baseline unit for testing. Since the unit was required to meet the 1993 NAECA standards, the energy consumption was quite low (1.676 kWh/d), thus making further reductions in energy consumption very challenging. Among the energy saving features incorporated into the original design of the baseline unit were a low-wattage evaporator fan, increased insulation thicknesses, and liquid line flange heaters.

Vineyard, E.A.; Sand, J.R.

1998-03-01T23:59:59.000Z

426

Fish passage mitigation of impacts from hydroelectric power projects in the United States  

DOE Green Energy (OSTI)

Obstruction of fish movements by dams continues to be the major environmental issue facing the hydropower industry in the US. Dams block upstream migrations, which can cut off adult fish form their historical spawning grounds and severely curtail reproduction. Conversely, downstream-migrating fish may be entrained into the turbine intake flow and suffer turbine-passage injury or mortality. Hydroelectric projects can interfere with the migrations of a wide variety of fish. Maintenance, restoration or enhancement of populations of these species may require the construction of facilities to allow for upstream and downstream fish passage. The Federal Energy Regulatory Commission (FERC), by law, must give fish and wildlife resources equal consideration with power production in its licensing decisions, must be satisfied that a project is consistent with comprehensive plans for a waterway (including fisheries management plans), and must consider all federal and state resource agency terms and conditions for the protection of fish and wildlife. As a consequence, FERC often requires fish passage mitigation measures as a condition of the hydropower license when such measures are deemed necessary for the protection of fish. Much of the recent research and development efforts of the US Department of Energy`s Hydropower Program have focused on the mitigation of impacts to upstream and downstream fish passage. This paper descries three components of that effort: (1) a survey of environmental mitigation measures at hydropower sites across the country; (2) a critical review of the effectiveness of fish passage mitigation measures at 16 case study sites; and (3) ongoing efforts to develop new turbine designs that minimize turbine-passage mortality.

Cada, G.F. [Oak Ridge National Lab., TN (United States). Environmental Sciences Div.

1996-10-01T23:59:59.000Z

427

Effect on the condition of the metal in A K-300-3.5 turbine owing to multicycle fatigue from participation of a power generating unit in grid frequency and power regulation  

Science Conference Proceedings (OSTI)

The effect on the condition of the rotor material owing to multicycle fatigue caused by variable stresses during participation of a power generating unit in grid frequency and power regulation is evaluated using the K-300-23.5 steam turbine as an example. It is shown that during normalized primary frequency regulation the safety factor is at least 50, while during automatic secondary regulation of frequency and power there is essentially no damage to the metal.

Lebedeva, A. I.; Zorchenko, N. V.; Prudnikov, A. A.

2011-09-15T23:59:59.000Z

428

Comparison of Several Eco-Friendly Refrigeration Technologies  

E-Print Network (OSTI)

In this paper, the operation principles, thermodynamics characteristics, and technical practicability were compared between thermoelectric refrigeration, magnetic refrigeration and adsorption refrigeration. The TE refrigeration is the most well-developed, applicable and competitive technology. Three eco-friendly refrigeration systems are increasingly getting attention, especially in a day with increasingly energy and environmental crises. In summary, thermoelectric refrigeration possesses the following superiorities: a longer developmental period, more perfect techniques, increasing applications, a larger range of refrigerating capacity, and a better economic property in small refrigerating capacity. Thermoelectric refrigeration cannot be replaced in special fields, and its applications have received more and more attention in recovering waste heat. Magnetic refrigeration has been widely applied in lower temperature regions; its application in middle temperature regions is juvenile. In particular, there is no application of this technique in high temperature regions. Adsorption refrigeration is practical only in near room temperatures. Its advantage is that it can be used in some fields where conventional refrigeration cannot be applied, such as in the application of solar energy, geothermal energy, and other renewable energy, and the recovery of residual and waste heat.? Supported by the Young Foundation of Central South University of Forestry & Technology (06002A) The disadvantages are as follows: the cost is expensive, no practical technique is available at present, and thus, it possesses no general superiority versus other refrigeration technologies.

Tang, C.; Luo, Q.; Li, X.; Zhu, X.

2006-01-01T23:59:59.000Z

429

Visions of Future Intelligent Power Grids: Synergies for Collaboration Between the European Union and the United States  

Science Conference Proceedings (OSTI)

The future of power grids is expected to involve an increasing level of intelligence and integration of new information and communication technologies in every aspect of the electricity system, from demand-side devices to wide-scale distributed generation to a variety of energy markets. The vision of this future in the United States and the European Union is known as GridWiseTM and SmartGrid, respectively. The results of the examination of similarities and complementarities of the two research programs are presented in this paper. Within the framework of a solid precedence for trans-Atlantic cooperation in energy research, the time would seem optimal to set in motion active collaboration and educational exchange on GridWise and SmartGrid research. This paper will provide energy professionals with a comparison of the solutions developed in each case, to be aware of trans-Atlantic approaches, opportunities, and resources looking toward future, more intelligent and interconnected power grids.

Coll-Mayor, Debora; Paget, Mia L.; Lightner, Eric M.; Sanchez-Jimenez, Manuel

2007-01-01T23:59:59.000Z

430

A comparative analysis of business structures suitable for farmer-owned wind power projects in the United States  

E-Print Network (OSTI)

Support for Community Wind Power Development. LBNL-54715.Analysis of Community Wind Power Development Options inWhip Up Hopes for Wind Power Again. ” The Wall Street

Bolinger, Mark; Wiser, Ryan

2004-01-01T23:59:59.000Z

431

The Impact of Wind Power Projects on Residential Property Values in the United States: A Multi-Site Hedonic Analysis  

E-Print Network (OSTI)

2002) Economic Impacts of Wind Power in Kittitas County, WA.about Large Offshore Wind Power: Underlying Factors. EnergyOpinion on Offshore Wind Power - Interim Report. University

Hoen, Ben

2010-01-01T23:59:59.000Z

432

China Refrigerator Information Label: Specification Development and Potential Impact  

SciTech Connect

In the last five years, China's refrigerator market has grown rapidly, and now urban markets are showing signs of saturation, with ownership rates in urban households reaching 92%. Rural markets continue to grow from a much lower base. As a result of this growth, the Chinese government in 2006 decided to revise the refrigerator standards and its associated efficiency grades for the mandatory energy information label. In the Chinese standards process, the efficiency grades for the information label are tied to the minimum standards. Work on the minimum standards revision began in 2006 and continued through the first half of 2007, when the draft standard was completed under the direction of the China National Institute of Standardization (CNIS). Development of the information label grades required consideration of stakeholder input, continuity with the previous grade classification, ease of implementation, and potential impacts on the market. In this process, CLASP, with the support of METI/IEEJ, collaborated with CNIS to develop the efficiency grades, providing technical input to the process, comment and advice on particular technical issues, and evaluation of the results. After three months of effort and three drafts of the final grade specifications, this work was completed. In addition, in order to effectively evaluate the impact of the label on China's market, CLASP further provided assistance to CNIS to collect data on both the efficiency distribution and product volume distribution of refrigerators on the market. The new information label thresholds to be implemented in 2008 maintain the approach first adopted in 2005 of establishing efficiency levels relative to the minimum standard, but increased the related required efficiency levels by 20% over those established in 2003 and implemented in 2005. The focus of improvement was on the standard refrigerator/freezer (class 5), which constitutes the bulk of the Chinese market. Indeed, the new requirements to achieve grade 1 on the label are now virtually as stringent as those for US Energy Star-qualified or EU A-grade refrigerators. When the energy information label went into effect in March 2005, refrigerator manufacturers were required to display their declared level of efficiency on the label and report it to the China Energy Label Center (CELC), a newly established unit of CNIS responsible for label program management. Because of the visible nature of the label, it was found, through a METI/IEEJ-supported study, that MEPS non-compliance dropped from 4% to zero after the label became mandatory, and that the percentage of higher-grade refrigerators increased. This suggests that the label itself does have potential for shifting the market to higher-efficiency models (Lin 2007). One challenge, however, of assessing this potential impact is the lack of a comprehensive baseline of market efficiency and a program to evaluate the market impact on a yearly basis. As a result, the impact evaluation in this study draws upon the market transformation experience of the related EU energy information label, for which quantitative assessments of its market impact exist. By assuming a parallel process unfolding in China, it is possible to look at the potential impact of the label to 2020. The results of the analysis demonstrates that a robust market transformation program in China focused on the energy information label could save substantial amounts of electricity by 2020, totaling 16.4 TWh annually by that year, compared to a case in which the efficiency distribution of refrigerators was frozen at the 2007 level. Remarkably, the impact of a successful market transformation program with the label would essentially flatten the consumption of electricity for refrigerator use throughout most of the next decade, despite the expectations of continued growth in total stock by nearly 190 million units. At the end of this period, total consumption begins to rise again, as the least efficient of the units have been mostly removed from the market. Such a level of savings would redu

Fridley, David; Fridley, David; Zheng, Nina; Zhou, Nan; Aden, Nathaniel; Lin, Jiang; Jianhong, Cheng; Sakamoto, Tomoyuki

2008-02-01T23:59:59.000Z

433

Optimal control system design of an acid gas removal unit for an IGCC power plants with CO2 capture  

Science Conference Proceedings (OSTI)

Future IGCC plants with CO{sub 2} capture should be operated optimally in the face of disturbances without violating operational and environmental constraints. To achieve this goal, a systematic approach is taken in this work to design the control system of a selective, dual-stage Selexol-based acid gas removal (AGR) unit for a commercial-scale integrated gasification combined cycle (IGCC) power plant with pre-combustion CO{sub 2} capture. The control system design is performed in two stages with the objective of minimizing the auxiliary power while satisfying operational and environmental constraints in the presence of measured and unmeasured disturbances. In the first stage of the control system design, a top-down analysis is used to analyze degrees of freedom, define an operational objective, identify important disturbances and operational/environmental constraints, and select the control variables. With the degrees of freedom, the process is optimized with relation to the operational objective at nominal operation as well as under the disturbances identified. Operational and environmental constraints active at all operations are chosen as control variables. From the results of the optimization studies, self-optimizing control variables are identified for further examination. Several methods are explored in this work for the selection of these self-optimizing control variables. Modifications made to the existing methods will be discussed in this presentation. Due to the very large number of candidate sets available for control variables and due to the complexity of the underlying optimization problem, solution of this problem is computationally expensive. For reducing the computation time, parallel computing is performed using the Distributed Computing Server (DCS®) and the Parallel Computing® toolbox from Mathworks®. The second stage is a bottom-up design of the control layers used for the operation of the process. First, the regulatory control layer is designed followed by the supervisory control layer. Finally, an optimization layer is designed. In this paper, the proposed two-stage control system design approach is applied to the AGR unit for an IGCC power plant with CO{sub 2} capture. Aspen Plus Dynamics® is used to develop the dynamic AGR process model while MATLAB is used to perform the control system design and for implementation of model predictive control (MPC).

Jones, D.; Bhattacharyya, D.; Turton, R.; Zitney, S.

2012-01-01T23:59:59.000Z

434

Teton Coin Op Laundry: heat recovery unit. Final report  

SciTech Connect

Experience with a heat recovery unit using Freon 11 refrigerant as a transfer medium is reported. Heat exchangers were fabricated for use in dryer stacks and the waste heat was used in heating the water for the laundry. (MHR)

1984-01-16T23:59:59.000Z

435

Cooling of superconducting devices by liquid storage and refrigeration unit  

SciTech Connect

A system is disclosed for cooling superconducting devices. The system includes a cryogen cooling system configured to be coupled to the superconducting device and to supply cryogen to the device. The system also includes a cryogen storage system configured to supply cryogen to the device. The system further includes flow control valving configured to selectively isolate the cryogen cooling system from the device, thereby directing a flow of cryogen to the device from the cryogen storage system.

Laskaris, Evangelos Trifon; Urbahn, John Arthur; Steinbach, Albert Eugene

2013-08-20T23:59:59.000Z

436

Energy Consumption of Refrigerators in Ghana - Outcomes of Household  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Consumption of Refrigerators in Ghana - Outcomes of Household Energy Consumption of Refrigerators in Ghana - Outcomes of Household Surveys Speaker(s): Essel Ben Hagan Date: July 12, 2007 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Robert Van Buskirk Galen Barbose As part of activities to develop refrigerator efficiency standards regulations in Ghana, a national survey on the energy consumption of refrigerators and refrigerator-freezers has been conducted. The survey covered 1000 households in urban, peri-urban and rural communities in various parts of the country. The survey found that, on average, refrigerators and refrigerator-freezers in Ghana use almost three times what is allowed by minimum efficiency standards in the U.S., and a few refrigerators had energy use at levels almost ten times the U.S.

437

Refrigerator Standards Save Consumers $ Billions | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Refrigerator Standards Save Consumers $ Billions Refrigerator Standards Save Consumers $ Billions Refrigerator Standards Save Consumers $ Billions March 5, 2013 - 10:35am Addthis Refrigerator Standards Refrigerator Standards Refrigerator technology has come a long way since Dr. John Gorrie (1803 - 1855), a forward-looking inventor, was granted U. S. Patent #8080 for mechanical refrigeration in 1851. In those days, ice was expensive, if it was even available: Blocks of natural ice were carved from frozen lakes and rivers and stored in special warehouses under layers of sawdust for insulation. By the 1890s, pollution and sewage dumping caused by population growth compromised sources of pure, natural ice, threatening the brewing, meat-packing, and dairy industries. As these and other industries sought better solutions, modern refrigeration technology started to evolve.

438

DOE Resolves Avanti Refrigerator and Freezer Civil Penalty Case  

Energy.gov (U.S. Department of Energy (DOE))

Today, the Department of Energy announced that it has resolved the civil penalty action against Mackle Company for its failure to certify that refrigerators and refrigerator-freezers sold under the...

439

VEE-0079 - In the Matter of Diversified Refrigeration, Inc.  

Energy.gov (U.S. Department of Energy (DOE))

Diversified Refrigeration, Inc. (DRI) requests a six-month exception from the 2001 energy appliance efficiency standards for built-in refrigerators that become effective July 1, 2001. As explained...

440

Integrating giant microwave absorption with magnetic refrigeration in one  

E-Print Network (OSTI)

Integrating giant microwave absorption with magnetic refrigeration in one multifunctional with magnetic refrigeration in one multifunctional material. This integration not only advances our EMI problem, it is becoming very urgent to design and fabricate the electromagnetic compatibility (EMC

Wang, Wei Hua

Note: This page contains sample records for the topic "refrigeration unit powered" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Thermoelectric refrigerator having improved temperature-stabilization means  

DOE Patents (OSTI)

A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized.

Falco, C.M.

1981-07-29T23:59:59.000Z

442

The Impact of Wind Power Projects on Residential Property Values in the United States: A Multi-Site Hedonic Analysis  

E-Print Network (OSTI)

Opinion about Large Offshore Wind Power: Underlying Factors.Delaware Opinion on Offshore Wind Power - Interim Report.

Hoen, Ben

2010-01-01T23:59:59.000Z

443

PTC, ITC, or Cash Grant? An Analysis of the Choice Facing Renewable Power Projects in the United States  

E-Print Network (OSTI)

hydroelectric, and marine and hydrokinetic power, are notmarine and hydrokinetic facilities. For wind, closed-loop biomass, and geothermal power,

Bolinger, Mark

2009-01-01T23:59:59.000Z

444

Nanostructured Materials for Magnetic Refrigeration  

Science Conference Proceedings (OSTI)

... of Nd-Fe-B Magnets to the Megawatt Scale Generator for the Wind Turbine ... Low Loss, High Power Density Magnetics in Inductor/Transformer Cores for Army  ...

445

Thermal Analysis of Refrigeration Systems Used for Vaccine ...  

Science Conference Proceedings (OSTI)

... Is this refrigerator model suitable for frozen vaccine storage? Freezer thermostat dial set to midpoint position: vaccine vial temperatures ...

2012-08-02T23:59:59.000Z

446

High Efficiency Low Emission Supermarket Refrigeration Research Project  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy (DOE) is currently conducting research into high efficiency, low emission supermarket refrigeration technologies.

447

International Refrigeration: Proposed Penalty (2012-CE-1510)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

International Refrigeration Products International Refrigeration Products (room air conditioners) ) ) ) ) ) Case Number: 2012-CE-1510 NOTICE OF PROPOSED CIVIL PENALTY Date issued: July 9, 2012 Number of alleged violations: 5475 (365 days, 15 models) Maximum possible assessment: $1,095,000 Proposed civil penalty: $109,500 The U.S. Department of Energy ("DOE") Office of the General Counsel, Office of Enforcement, alleges that International Refrigeration Products ("IRP") has violated cettain provisions of the Energy Policy and Conservation Act, 42 U.S.C. § 6291 et seq. ("the Act"), and 10 C.P.R. § 429.12. Specifically, DOE alleges: 1. IRP has manufactured 1 a variety of Sea Breeze brand room air conditioners, including basic models WA46YR, WA48YRX, WA410YRX, WA412YRX, WH418ZRX,

448

Of Refrigerators & Regulations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Of Refrigerators & Regulations Of Refrigerators & Regulations Of Refrigerators & Regulations February 8, 2011 - 9:29am Addthis Jesse Lee White House Director of Online Affairs Editor's Note: This entry has been cross-posted from The White House Blog. For those interested in the President's remarks to the U.S. Chamber of Commerce and his views on the shared responsibilities of government and business to the American people, our post earlier will give a suitable overview. For those interested in the details of the President's Executive Order on reviewing regulations and their impacts on the economy, Cass Sunstein's post this morning will also be of value. But the President also took a moment during his speech to put the debate over regulation in a different perspective, and to break through the false dichotomy so often

449

ENVIRONMENTAL ASSESSMENT FOR THE PROPOSED ENERGY CONSERVATION STANDARD FOR REFRIGERATORS, REFRIGERATOR-  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ASSESSMENT FOR THE PROPOSED ENERGY ASSESSMENT FOR THE PROPOSED ENERGY CONSERVATION STANDARD FOR REFRIGERATORS, REFRIGERATOR- , AND FREEZERS - 1. INTRODUCTION AND NEED FOR PROPOSED ACTION ental Assessment (EA) on the candidate energy conservation stand licy Act. of 1969 (NEPA), regulations of the Council on Environmentd Qu refrigerators, re€iigerator-freezers, and freezers was prepared pursuant to the National ' ederal Regulations, Parts 1500 through. 1508. The proposed energy conservation standard (Level 1) and the alternative standards are being reviewed in an energy- efficiency standards rulemaking that the Department has undertaken pursuant to the Energy Policy and Conservation Act, as amended by the National Energy Conservation Policy Act and the National Appliance Energy Consehation Act

450

Reducing the Carbon Footprint of Commercial Refrigeration Systems Using Life Cycle Climate Performance Analysis: From System Design to Refrigerant Options  

SciTech Connect

In this paper, Life Cycle Climate Performance (LCCP) analysis is used to estimate lifetime direct and indirect carbon dioxide equivalent gas emissions of various refrigerant options and commercial refrigeration system designs, including the multiplex DX system with various hydrofluorocarbon (HFC) refrigerants, the HFC/R744 cascade system incorporating a medium-temperature R744 secondary loop, and the transcritical R744 booster system. The results of the LCCP analysis are presented, including the direct and indirect carbon dioxide equivalent emissions for each refrigeration system and refrigerant option. Based on the results of the LCCP analysis, recommendations are given for the selection of low GWP replacement refrigerants for use in existing commercial refrigeration systems, as well as for the selection of commercial refrigeration system designs with low carbon dioxide equivalent emissions, suitable for new installations.

Fricke, Brian A [ORNL; Abdelaziz, Omar [ORNL; Vineyard, Edward Allan [ORNL

2013-01-01T23:59:59.000Z

451

ASHRAE/NIST Refrigerants Conference International concerns about the impact of refrigerants on climate change drive the  

E-Print Network (OSTI)

ASHRAE/NIST Refrigerants Conference International concerns about the impact of refrigerants conference between ASHRAE and NIST. Supporting Organizations: NOTE: Registration closes Oct. 18 and includes conference proceedings, daily lunch and dinner Monday evening. ASHRAE Members: $425 Non

Fernández-Juricic, Esteban

452

Refrigeration needs for sustainable preservation of horticultural products  

Science Conference Proceedings (OSTI)

Fresh horticultural products are highly perishable and need refrigeration for further preservation. Refrigeration needs energy consumption with consequent economical cost and damage for the environment. The objective of the present work was to use efficiently ... Keywords: energy efficiency, food salads, halophytes, postharvest technologies, refrigeration, safe food, sustainability

Custódia Gago; Ana Rita Sousa; Miriam Julião; Graça Miguel; Dulce Antunes; Thomas Panagopoulos

2011-02-01T23:59:59.000Z

453

Literature survey of heat transfer enhancement techniques in refrigeration applications  

Science Conference Proceedings (OSTI)

A survey has been performed of the technical and patent literature on enhanced heat transfer of refrigerants in pool boiling, forced convection evaporation, and condensation. Extensive bibliographies of the technical literature and patents are given. Many passive and active techniques were examined for pure refrigerants, refrigerant-oil mixtures, and refrigerant mixtures. The citations were categorized according to enhancement technique, heat transfer mode, and tube or shell side focus. The effects of the enhancement techniques relative to smooth and/or pure refrigerants were illustrated through the discussion of selected papers. Patented enhancement techniques also are discussed. Enhanced heat transfer has demonstrated significant improvements in performance in many refrigerant applications. However, refrigerant mixtures and refrigerant-oil mixtures have not been studied extensively; no research has been performed with enhanced refrigerant mixtures with oil. Most studies have been of the parametric type; there has been inadequate examination of the fundamental processes governing enhanced refrigerant heat transfer, but some modeling is being done and correlations developed. It is clear that an enhancement technique must be optimized for the refrigerant and operating condition. Fundamental processes governing the heat transfer must be examined if models for enhancement techniques are to be developed; these models could provide the method to optimize a surface. Refrigerant mixtures, with and without oil present, must be studied with enhancement devices; there is too little known to be able to estimate the effects of mixtures (particularly NARMs) with enhanced heat transfer. Other conclusions and recommendations are offered.

Jensen, M.K.; Shome, B. [Rensselaer Polytechnic Inst., Troy, NY (United States). Dept. of Mechanical Engineering, Aeronautical Engineering and Mechanics

1994-05-01T23:59:59.000Z

454

Control method for mixed refrigerant based natural gas liquefier  

DOE Patents (OSTI)

In a natural gas liquefaction system having a refrigerant storage circuit, a refrigerant circulation circuit in fluid communication with the refrigerant storage circuit, and a natural gas liquefaction circuit in thermal communication with the refrigerant circulation circuit, a method for liquefaction of natural gas in which pressure in the refrigerant circulation circuit is adjusted to below about 175 psig by exchange of refrigerant with the refrigerant storage circuit. A variable speed motor is started whereby operation of a compressor is initiated. The compressor is operated at full discharge capacity. Operation of an expansion valve is initiated whereby suction pressure at the suction pressure port of the compressor is maintained below about 30 psig and discharge pressure at the discharge pressure port of the compressor is maintained below about 350 psig. Refrigerant vapor is introduced from the refrigerant holding tank into the refrigerant circulation circuit until the suction pressure is reduced to below about 15 psig, after which flow of the refrigerant vapor from the refrigerant holding tank is terminated. Natural gas is then introduced into a natural gas liquefier, resulting in liquefaction of the natural gas.

Kountz, Kenneth J. (Palatine, IL); Bishop, Patrick M. (Chicago, IL)

2003-01-01T23:59:59.000Z

455

Retrofitting Doors on Open Refrigerated Cases  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Retrofitting Doors on Open Retrofitting Doors on Open Refrigerated Cases William Goetzler Navigant Consulting, Inc. wgoetzler@navigant.com (781) 270-8351 April 4, 2013 BBA Refrigeration Project Team Images courtesy of REMIS AMERICA, LLC. 2 | Building Technologies Office eere.energy.gov Technology Overview Image from Investigation of Energy- Efficient Supermarket Display Cases. 2004, Oak Ridge National Laboratory. Background and Motivation * Adding doors to open cases (retrofits) greatly reduces cold air loss - 50-80% load reduction - Load reduction = system energy savings

456

Floating Loop System For Cooling Integrated Motors And Inverters Using Hot Liquid Refrigerant  

DOE Patents (OSTI)

A floating loop vehicle component cooling and air-conditioning system having at least one compressor for compressing cool vapor refrigerant into hot vapor refrigerant; at least one condenser for condensing the hot vapor refrigerant into hot liquid refrigerant by exchanging heat with outdoor air; at least one floating loop component cooling device for evaporating the hot liquid refrigerant into hot vapor refrigerant; at least one expansion device for expanding the hot liquid refrigerant into cool liquid refrigerant; at least one air conditioning evaporator for evaporating the cool liquid refrigerant into cool vapor refrigerant by exchanging heat with indoor air; and piping for interconnecting components of the cooling and air conditioning system.

Hsu, John S [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN; Coomer, Chester [Knoxville, TN; Marlino, Laura D [Oak Ridge, TN

2006-02-07T23:59:59.000Z

457

Carbon Dioxide and Ionic Liquid Refrigerants: Compact, Efficient Air Conditioning with Ionic Liquid-Based Refrigerants  

SciTech Connect

BEETIT Project: Notre Dame is developing an air-conditioning system with a new ionic liquid and CO2 as the working fluid. Synthetic refrigerants used in air conditioning and refrigeration systems are potent GHGs and can trap 1,000 times more heat in the atmosphere than CO2 alone—making CO2 an attractive alternative for synthetic refrigerants in cooling systems. However, operating cooling systems with pure CO2 requires prohibitively high pressures and expensive hardware. Notre Dame is creating a new fluid made of CO2 and ionic liquid that enables the use of CO2 at low pressures and requires minimal changes to existing hardware and production lines. This new fluid also produces no harmful emissions and can improve